WorldWideScience

Sample records for contact lens implantation

  1. Analysis of phakic before intraocular lens implantation for fundus examination

    OpenAIRE

    Juan Chen; Zhong-Ping Chen; Rui-Ling Zhu

    2014-01-01

    AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL). To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examina...

  2. Contact Lens Visual Rehabilitation in Keratoconus and Corneal Keratoplasty

    Directory of Open Access Journals (Sweden)

    Yelda Ozkurt

    2012-01-01

    Full Text Available Keratoconus is the most common corneal distrophy. It’s a noninflammatory progressive thinning process that leads to conical ectasia of the cornea, causing high myopia and astigmatism. Many treatment choices include spectacle correction and contact lens wear, collagen cross linking, intracorneal ring segments implantation and finally keratoplasty. Contact lenses are commonly used to reduce astigmatism and increase vision. There are various types of lenses are available. We reviewed soft contact lenses, rigid gas permeable contact lenses, piggyback contact lenses, hybrid contact lenses and scleral-semiscleral contact lenses in keratoconus management. The surgical option is keratoplasty, but even after sutur removal, high astigmatism may stil exists. Therefore, contact lens is an adequate treatment option to correct astigmatism after keratoplasty.

  3. Contact Lens Care

    Science.gov (United States)

    ... Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More sharing ... www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative Contact ...

  4. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...

  5. The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation.

    Science.gov (United States)

    Qi, Meng-Ying; Chen, Qian; Zeng, Qing-Yan

    2017-08-01

    To identify associations between crystalline lens-related factors and central vault after Implantable Collamer Lens (ICL) (Staar Surgical, Monrovia, CA) implantation. This retrospective clinical study included 320 eyes from 186 patients who underwent ICL implantation surgery. At 1 year after surgery, the central vault was measured using anterior segment optical coherence tomography. Preoperative anterior chamber depth, lens thickness, lens position (lens position = anterior chamber depth + 1/2 lens thickness), and vault were analyzed to investigate the effects of lens-related factors on postoperative vault. The mean vault was 513 ± 215 µm at 1 year after surgery. Vault was positively correlated with preoperative anterior chamber depth (r = 0.495, P lens position (r = 0.371, P lens thickness (r = -0.262, P lens position than eyes in the other two vault groups (which had vaults ≥ 250 µm) (P lens position less than 5.1 mm had greatly reduced vaults (P lens could have an important influence on postoperative vault. Eyes with a shallower anterior chamber and a forward lens position will have lower vaults. [J Refract Surg. 2017;33(8):519-523.]. Copyright 2017, SLACK Incorporated.

  6. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  7. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  8. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  9. Application of fibrin glue with bandage contact lens in pterygium surgery

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2014-05-01

    Full Text Available AIM: To explore the efficacy of fibrin glue with bandage contact lens for pain relief after pterygium surgery performed with limbal autograft transplantation.METHODS: A prospective clinical trial was carried out in 52 patients(72 eyesoperated for primary nasal pterygium. All patients were randomly divided into the fibrin glue with bandage contact lens group(experimental group, 28 cases, 38 eyesand suture group(control group, 24 cases, 34 eyes. Autologous limbal graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision under local anesthesia with 20g/L lidocaine. In experimental group, the transplant was attached to the sclera with fibrin tissue adhesive and in control group with 10-0 Virgin silk sutures. Experimental group weared bandage contact lens after surgery while the control group did not. The degree of pain after surgery was evaluated at 1, 2, 3, 5 and 7d after surgery. Follow-up was 6mo, matching degree of graft and complication such as infection, relapse, implant healing badness and subconjunctival cyst were mainly observed and recorded.RESULTS: The pain index scores of the experimental group were significantly less than those of control group(all P=0.000. In observation period, all conjunctival autografts in both groups were successfully attached and were intact without falling off, dissolution or recurrence and there were no complications such as infection, relapse, implant healing badness and subconjunctival cyst.CONCLUSION: Fibrin glue with bandage contact lens could significantly release pain response afterpterygium excision surgery.

  10. Contact lenses fitting after intracorneal ring segments implantation in keratoconus

    Directory of Open Access Journals (Sweden)

    Luciane Bugmann Moreira

    2013-08-01

    Full Text Available PURPOSE: Evaluate contact lenses fitting after intracorneal ring implantation for keratoconus, its visual acuity and comfort. METHODS: Retrospective study of patients undergoing contact lenses fitting, after intracorneal ring for keratoconus. The criterion for contact lens fitting was unsatisfactory visual acuity with spectacle correction as referred by the patients. All patients were intolerants to contact lenses prior to intracorneal implantation. Visual acuity analysis was done by conversion of Snellen to logMAR scales. The comfort was evaluated according subjective questioning of good, medium or poor comfort. RESULTS: Nineteen patients were included in the study. Two patients (10.5% did not achieved good comfort with contact lenses and underwent penetrating keratoplasties. All the others 17 patients showed good or medium comfort. Four rigid gas-permeable contact lenses were fitted, one piggyback approach, 3 toric soft contact lenses, 2 soft lenses specially design for keratoconus and 7 disposable soft lenses. The average visual acuity improved from 0.77 ± 0.37 to 0.19 ± 0.13 logMAR units after contact lenses fitting. CONCLUSION: Contact lens fitting after intracorneal ring is possible, provides good comfort, improves visual acuity, and therefore, may postpone the need for penetrating keratoplasty.

  11. Analysis of phakic before intraocular lens implantation for fundus examination

    Directory of Open Access Journals (Sweden)

    Juan Chen

    2014-10-01

    Full Text Available AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL. To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examination by three mirror from April 2011 to April 2012 in our hospital. The age, refractive diopter, the findings of Goldmann three mirror examination and the condition of retinal photocoagulation were analysed and concluded.RESULTS: A total of 34 eyes(26.8%out of all 127 eyes(64 caseswere found to have peripheral retinal pathological changes. Eight eyes(6.3%with retinal holes, 15 eyes(11.8%with retinal lattice degeneration, 5 eyes(3.9%with retina cream degeneration, 3 eyes(2.4%with retinal paving stone degeneration,2 eyes with vitreoretinal adhesion and traction,1 eye(0.8%with retinal hemorrhage. Twenty-five cases were given retinal photocoagulation and then received the ICL implantation after 3mo. The follow-up time was 1a. No retinal detachment happened.CONCLUSION:Phakic before intraocular lens implantation for fundus examination by three mirror is contributed to find the peripheral retinal pathological changes and abnormity. And make the appropriate treatment before operation for improving the security of operation, it can also give help to the postoperative follow-up of the fundus of these patients.

  12. Tinting of intraocular lens implants

    International Nuclear Information System (INIS)

    Zigman, S.

    1982-01-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users

  13. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  14. Pseudophakic hyperopia in nanophthalmic eyes managed by a posterior chamber implantable collamer lens

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2011-01-01

    Full Text Available We report a case of a bilateral posterior chamber implantable collamer lens (ICL implantation post-clear lens extraction, to reduce the residual hyperopia, in a patient with nanophthalmic eyes. A 30-year-old female patient, keen to reduce her dependency on glasses and contact lenses, came to our refractive surgery department. Her refractive error was +12.0 and +12.5 diopters in the right and left eye, respectively, with steep corneas on keratometry and a shallow anterior chamber depth. She underwent clear lens extraction with implantation of +35.0 D and +40.0 D IOL in the right eye and left eye, respectively. Her post-operative best-corrected visual acuity was 20/30 with +8.5 D in the right eye and +6 D in the left. She underwent bilateral ICL implantation. Postoperatively after 6 months, her unaided visual acuity was 20/30 in both eyes. In conclusion, ICL implantation can be considered to correct residual hypermetropic ametropia in pseudophakic eyes when other options have limitations.

  15. Contact Lens Risks

    Science.gov (United States)

    ... There is a risk of eye infection from bacteria in swimming pool water, hot tubs, lakes and the ocean Replace your contact lens storage case every 3 months or as directed by your eye care professional. Other Risks of Contact Lenses Other risks of contact lenses include pink eye ( ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  18. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique.

    Science.gov (United States)

    Canut Jordana, M Isabel; Pérez Formigó, Daniel; Abreu González, Rodrigo; Nadal Reus, Jeroni

    2010-11-11

    We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.

  19. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p rate, self grading was relatively high. Therefore, these results indicate the need for patient education and encouragement of better lens wearing habits and all of the lens maintenance steps at each patient visit.

  20. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  1. Contact lens rehabilitation following repaired corneal perforations

    Science.gov (United States)

    Titiyal, Jeewan S; Sinha, Rajesh; Sharma, Namrata; Sreenivas, V; Vajpayee, Rasik B

    2006-01-01

    Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries. PMID:16536877

  2. [Phacoemulsification of subluxated lens with capsular tension ring implantation].

    Science.gov (United States)

    Dorecka, Mariola; Rokicki, Wojciech; Nita, Malgorzata; Krysik, Katarzyna; Nita, Ewa; Sikorska, Aleksandra; Romaniuk, Wanda

    2007-01-01

    To evaluate long term results of phacoemulsification with PC IOL and capsular tension ring (CTR) implantation in lens subluxation. The study comprised of 134 patients--146 eyes with subluxated lens. In all cases phacoemulsification with PC IOL and CTR implantation was performed. No intaroperative complications has occured. Postoperative complications included: inflammation in the anterior chamber in 3 eyes (2.1%), retinal detachment in 2 eyes (1.4%). In all cases there was no PC IOL decentration. (1) CTR facilitates phacoemulsification with PC IOL implantation in lens subluxation. (2) Phacoemulsification of subluxated lens with PC IOL and CTR implantation seems to be safe and effective procedure.

  3. High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients.

    Science.gov (United States)

    Sengor, Tomris; Kurna, Sevda Aydin; Aki, Suat; Ozkurt, Yelda

    2011-01-01

    The aim of the study was to examine the clinical success of high Dk (oxygen permeability) piggyback contact lens (PBCL) systems for the correction of contact lens intolerant keratoconus patients. Sixteen patients (29 eyes) who were not able to wear gas-permeable rigid lenses were included in this study. Hyper Dk silicone hydrogel (oxygen transmissibility or Dk/t = 150 units) and fluorosilicone methacrylate copolymer (Dk/t = 100 units) lenses were chosen as the PBCL systems. The clinical examinations included visual acuity and corneal observation by biomicroscopy, keratometer reading, and fluorescein staining before and after fitting the PBCL system. INDICATIONS FOR USING PBCL SYSTEM WERE: lens stabilization and comfort, improving comfort, and adding protection to the cone. Visual acuities increased significantly in all of the patients compared with spectacles (P = 0). Improvement in visual acuity compared with rigid lenses alone was recorded in 89.7% of eyes and no alteration of the visual acuity was observed in 10.3% of the eyes. Wearing time of PBCL systems for most of the patients was limited time (mean 6 months, range 3-12 months); thereafter they tolerated rigid lenses alone except for 2 patients. The PBCL system is a safe and effective method to provide centering and corneal protection against mechanical trauma by the rigid lenses for keratoconus patients and may increase contact lens tolerance.

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... glow-in-the-dark lizard lenses, costume contacts can certainly add a spooky, eye-popping touch. But ... consideration as a standard contact lens because they can be purchased over-the-counter or on the ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  7. Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

    Science.gov (United States)

    Venter, Jan A; Oberholster, Andre; Schallhorn, Steven C; Pelouskova, Martina

    2014-04-01

    To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to correct residual refractive error were analyzed. All eyes previously had in-the-bag zonal refractive multifocal intraocular lens implantation (Lentis Mplus MF30, models LS-312 and LS-313; Oculentis GmbH, Berlin, Germany) and required residual refractive error correction. Outcome measurements included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, manifest refraction, and complications. One-year data are presented in this study. The mean spherical equivalent ranged from -1.75 to +3.25 diopters (D) preoperatively (mean: +0.58 ± 1.15 D) and reduced to -1.25 to +0.50 D (mean: -0.14 ± 0.28 D; P < .01). Postoperatively, 93.8% of eyes were within ±0.50 D and 98.8% were within ±1.00 D of emmetropia. The mean uncorrected distance visual acuity improved significantly from 0.28 ± 0.16 to 0.01 ± 0.10 logMAR and 78.8% of eyes achieved 6/6 (Snellen 20/20) or better postoperatively. The mean uncorrected near visual acuity changed from 0.43 ± 0.28 to 0.19 ± 0.15 logMAR. There was no significant change in corrected distance visual acuity or distance-corrected near visual acuity. No serious intraoperative or postoperative complications requiring secondary intraocular lens removal occurred. Sulcoflex lenses proved to be a predictable and safe option for correcting residual refractive error in patients diagnosed as having pseudophakia. Copyright 2014, SLACK Incorporated.

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  10. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  11. First contact diagnosis and management of contact lens-related complications.

    Science.gov (United States)

    Fagan, Xavier J; Jhanji, Vishal; Constantinou, Marios; Amirul Islam, F M; Taylor, Hugh R; Vajpayee, Rasik B

    2012-08-01

    To describe the spectrum of contact lens-related problems in cases presenting to a tertiary referral eye hospital. A retrospective case record analysis of 111 eyes of 97 consecutive patients was undertaken over a period of five months at the Royal Victorian Eye and Ear Hospital, Melbourne, Australia. Contact lens-related complications (CLRC) were classified into microbial keratitis, sterile corneal infiltrates, corneal epitheliopathy and contact lens-related red eye (CLARE). Main parameters examined were nature of the first contact, clinical diagnosis, and management pattern. Forty-two percent of the initial presentations were to health care practitioners (HCPs) other than ophthalmologists. Mean duration from the onset of symptoms to presentation was 6.3 ± 10.9 days. Forty-nine percent (n = 54) of patients had an associated risk factor, most commonly overnight use of contact lenses (n = 14, 13 %). Most common diagnosis at presentation was corneal epitheliopathy (68 %) followed by sterile infiltrates (10 %), CLARE (8 %) and microbial keratitis (6 %). No significant differences were found in the pattern of treatment modalities administered by ophthalmologists and other HCPs. HCPs other than ophthalmologists are the first contact for contact lens-related problems in a significant proportion of patients. These HCPs manage the majority of CLRC by direct treatment or immediate referral.

  12. Comparison of clear lens extraction and collamer lens implantation in high myopia

    Directory of Open Access Journals (Sweden)

    Ahmed M Emarah

    2010-05-01

    Full Text Available Ahmed M Emarah, Mostafa A El-Helw, Hazem M YassinCairo University, Cairo, EgyptAim: To compare the outcomes of clear lens extraction and collamer lens implantation in high myopia.Patients and methods: Myopic patients younger than 40 years old with more than 12 diopters of myopia or who were not fit for laser-assisted in situ keratomileusis were included. Group 1 comprised patients undergoing clear lens extraction and Group 2 patients received the Visian implantable collamer lens. Outcome and complications were evaluated.Results: Postoperative best corrected visual acuity was -0.61 ± 0.18 in Group 1 and 0.79 ± 0.16 in Group 2. In Group 1, 71.4% achieved a postoperative uncorrected visual acuity better than the preoperative best corrected visual acuity, while only 51.8% patients achieved this in Group 2. Intraocular pressure decreased by 12.55% in Group 1, and increased by 15.11% in Group 2. Corneal endothelial cell density decreased by 4.47% in Group 1 and decreased by 5.67% in Group 2. Posterior capsule opacification occurred in Group 1. In Group 2, lens opacification occurred in 11.11%, significant pigment dispersion in 3.7%, and pupillary block glaucoma in 3.7%.Conclusion: Clear lens extraction presents less of a financial load up front, and less likelihood of the need for a secondary intervention in the future. Clear lens extraction is a more viable solution in developing countries with limited financial resources.Keywords: clear lens extraction, implantable collamer lens, myopia

  13. Disinfection capacity of PuriLens contact lens cleaning unit against Acanthamoeba.

    Science.gov (United States)

    Hwang, Thomas S; Hyon, Joon Young; Song, Jae Kyung; Reviglio, Victor E; Spahr, Harry T; O'Brien, Terrence P

    2004-01-01

    The PuriLens contact lens system is indicated for cleaning and disinfection of soft (hydrophilic) contact lenses by means of subsonic agitation to remove lens deposits and microorganisms, and ultraviolet irradiation of the storage solution for disinfection. The capacity of the PuriLens system to disinfect storage solutions contaminated with known concentrations of Staphylococcus aureus, Pseudomonas aeruginosa, and Acanthamoeba species was evaluated. An in vitro assessment of the antibacterial and antiparasitic efficacy of the PuriLens system was performed. Separated batches of the storage solution for the cleansing system were contaminated with stock strains of S. aureus and P. aeruginosa. A comparison of the microbiologic content was made between the solution before and after the cycle. The PuriLens system effectively eradicated S. aureus and P. aeruginosa organisms after a 15-minute cycle. However, viable cysts of acanthamoeba were recovered in the solution after the 15-minute cycle. The PuriLens system is highly efficient in protecting against contamination with common bacterial ocular pathogens. Acanthamoeba cysts, however, can survive in the solution or contact lens bath undergoing integrated subsonic debridement and indirect ultraviolet light disinfection. Use of chemical disinfecting solutions that contain agents such as chlorhexidine or other cationic antiseptics may be advisable in conjunction with use of the PuriLens device, especially in high-risk settings.

  14. Microbial contamination of soft contact lenses & accessories in asymptomatic contact lens users

    Directory of Open Access Journals (Sweden)

    Deeksha V Thakur

    2014-01-01

    Full Text Available Background & objectives: With increasing use of soft contact lenses the incidence of contact lens induced infections is also increasing. This study was aimed to assess the knowledge of new and existing contact lens users about the risk of microbial contamination associated with improper use and maintenance of contact lenses, type of microbial flora involved and their potential to cause ophthalmic infections. Methods: Four samples each from 50 participants (n=200 were collected from the lenses, lens care solutions, lens care solution bottles and lens cases along with a questionnaire regarding their lens use. The samples were inoculated onto sheep blood agar, Mac Conkey′s agar and Sabouraud′s dextrose agar. Organisms were identified using standard laboratory protocols. Results: Overall rate of microbial contamination among the total samples was 52 per cent. The most and the least contaminated samples were found to be lens cases (62% and lens care solution (42%, respectively. The most frequently isolated contaminant was Staphylococcus aureus (21% followed by Pseudomonas species (19.5%. Majority (64% of the participants showed medium grade of compliance to lens cleaning practices. Rate of contamination was 100 and 93.75 per cent respectively in those participants who showed low and medium compliance to lens care practices as compared to those who had high level of compliance (43.75% ( p0 <0.05. Interpretation & conclusions: Lens care practices amongst the participants were not optimum which resulted into high level contamination. Hence, creating awareness among the users about the lens care practices and regular cleaning and replacements of lens cases are required.

  15. Fabricating customized hydrogel contact lens

    Science.gov (United States)

    Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.

    2016-10-01

    Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.

  16. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  17. Applanation tonometry in silicone hydrogel contact lens wearers.

    Science.gov (United States)

    Allen, R J; Dev Borman, A; Saleh, G M

    2007-12-01

    Previous studies have investigated intraocular pressure (IOP) measurements through conventional soft (hydrogel) therapeutic contact lenses, and have found that an accurate IOP can be recorded in normal eyes, and in eyes with abnormal anterior segments. The IOP measurement through soft contact lenses may be affected by the water content and centre thickness of the lens. Silicone hydrogel contact lenses are now being used as therapeutic contact lenses due to their high oxygen permeability. The purpose of this study is to investigate if IOP can be accurately measured in a subject wearing a silicone hydrogel contact lens. In a cohort study, the IOP was measured with a Goldmann applanation tonometer without a contact lens and then repeated with a hydrogel contact lens in situ. The IOP of 20 eyes of 10 volunteers with no ocular pathology was measured. The mean difference (+/-S.D.) found between IOP measurement with (mean 15.55+/-1.70 mmHg) and without (mean 16.05+/-1.90 mmHg) contact lens was found to be -0.5+/-0.89 mmHg. Statistical analysis was performed which revealed a correlation coefficient of 0.89. No significant statistical difference was found between the two groups with paired t-test (p=0.19). Accurate measurement of IOP by applanation tonometry can be achieved through a silicone hydrogel contact lens.

  18. Effect of contact lens use on Computer Vision Syndrome.

    Science.gov (United States)

    Tauste, Ana; Ronda, Elena; Molina, María-José; Seguí, Mar

    2016-03-01

    To analyse the relationship between Computer Vision Syndrome (CVS) in computer workers and contact lens use, according to lens materials. Cross-sectional study. The study included 426 civil-service office workers, of whom 22% were contact lens wearers. Workers completed the Computer Vision Syndrome Questionnaire (CVS-Q) and provided information on their contact lenses and exposure to video display terminals (VDT) at work. CVS was defined as a CVS-Q score of 6 or more. The covariates were age and sex. Logistic regression was used to calculate the association (crude and adjusted for age and sex) between CVS and individual and work-related factors, and between CVS and contact lens type. Contact lens wearers are more likely to suffer CVS than non-lens wearers, with a prevalence of 65% vs 50%. Workers who wear contact lenses and are exposed to the computer for more than 6 h day(-1) are more likely to suffer CVS than non-lens wearers working at the computer for the same amount of time (aOR = 4.85; 95% CI, 1.25-18.80; p = 0.02). Regular contact lens use increases CVS after 6 h of computer work. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  19. The effect of compliance on contact lens case contamination.

    Science.gov (United States)

    Tilia, Daniel; Lazon de la Jara, Percy; Zhu, Hua; Naduvilath, Thomas J; Holden, Brien A

    2014-03-01

    To determine the efficacy of written instructions on contact lens case hygiene and to quantify the effect of noncompliance on contact lens case contamination. Data were retrospectively analyzed from 16 prospective, 3-month daily-wear studies during which six commercially available silicone hydrogel contact lenses and seven lens care solutions (LCS) were tested following a similar protocol. Verbal instructions regarding case hygiene (rinse case with LCS, not tap water) were given in nine studies, while the same instructions were given verbally and in written format in seven studies. A survey on contact lens, LCS, and lens case hygiene was completed at 1- and 3-month visits and compliance with case hygiene instructions was determined. Regular contact lens cases were used for 1 month and collected for microbial analysis at the 1- and 3-month visits. The rate of case contamination and the types of microbes contaminating cases were evaluated. Participants given verbal and written instructions were more likely to be compliant with case hygiene instructions than those just given verbal instructions (odds ratio [OR]: 2.19, p hygiene can be improved by effective communication of instructions. Contact lens wearers should be actively discouraged from rinsing contact lens cases with tap water because of the increased risk of GNB contamination.

  20. Oxygen transport through soft contact lens and cornea: Lens characterization and metabolic modeling

    Science.gov (United States)

    Chhabra, Mahendra

    The human cornea requires oxygen to sustain metabolic processes critical for its normal functioning. Any restriction to corneal oxygen supply from the external environment (e.g., by wearing a low oxygen-permeability contact lens) can lead to hypoxia, which may cause corneal edema (swelling), limbal hyperemia, neovascularization, and corneal acidosis. The need for adequate oxygen to the cornea is a major driving force for research and development of hypertransmissible soft contact lenses (SCLs). Currently, there is no standard technique for measuring oxygen permeability (Dk) of hypertransmissible silicone-hydrogel SCLs. In this work, an electrochemistry-based polarographic apparatus was designed, built, and operated to measure oxygen permeability in hypertransmissible SCLs. Unlike conventional methods where a range of lens thickness is needed for determining oxygen permeabilities of SCLs, this apparatus requires only a single lens thickness. The single-lens permeameter provides a reliable, efficient, and economic tool for measuring oxygen permeabilities of commercial hypertransmissible SCLs. The single-lens permeameter measures not only the product Dk, but, following modification, it measures separately diffusivity, D, and solubility, k, of oxygen in hypertransmissible SCLs. These properties are critical for designing better lens materials that ensure sufficient oxygen supply to the cornea. Metabolism of oxygen in the cornea is influenced by contact-lens-induced hypoxia, diseases such as diabetes, surgery, and drug treatment, Thus, estimation of the in-vivo corneal oxygen consumption rate is essential for gauging adequate oxygen supply to the cornea. Therefore, we have developed an unsteady-state reactive-diffusion model for the cornea-contact-lens system to determine in-vivo human corneal oxygen-consumption rate. Finally, a metabolic model was developed to determine the relation between contact-lens oxygen transmissibility (Dk/L) and corneal oxygen deficiency. A

  1. Customer loyalty among daily disposable contact lens wearers.

    Science.gov (United States)

    Patel, Neelam I; Naroo, Shehzad A; Eperjesi, Frank; Rumney, Nicholas J

    2015-02-01

    Optometric practices offer contact lenses as cash sale items or as part of monthly payment plans. With the contact lens market becoming increasingly competitive, patients are opting to purchase lenses from supermarkets and Internet suppliers. Monthly payment plans are often implemented to improve loyalty. This study aimed to compare behavioural loyalty between monthly payment plan members and non-members. BBR Optometry Ltd offers a monthly payment plan (Eyelife™) to their contact lens wearers. A retrospective audit of 38 Eyelife™ members (mean±SD: 42.7±15.0 years) and 30 non-members (mean±SD: 40.8±16.7 years) was conducted. Revenue and profits generated, service uptake and product sales between the two groups were compared over a fixed period of 18 months. Eyelife™ members generated significantly higher professional fee revenue (Ployalty among contact lens wearers, particularly service uptake and volume of lens purchases. Additionally the greater professional fees generated, render monthly payment plans an attractive business model and practice builder. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. Contact lens wear and dry eyes: challenges and solutions

    Directory of Open Access Journals (Sweden)

    Markoulli M

    2017-02-01

    Full Text Available Maria Markoulli, Sailesh Kolanu School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia Abstract: The number of contact lens wearers worldwide has remained relatively stable over the past decade, despite the investment that has gone into contact lens technology. This is largely because 10%–50% of wearers dropout of contact lens wear within 3 years of commencement; the most common reason cited being contact lens discomfort (CLD. Of the symptoms reported, sensation of dry eye is the most common. Given the outcome of reduced wearing time, increased chair time, and ultimate contact lens discontinuation, the challenge is to identify the warning signs of CLD early on. Clinically detectable changes such as conjunctival staining, conjunctival indentation, conjunctival epithelial flap formation, lid wiper epitheliopathy, Demodex blepharitis, and meibomian gland dysfunction have been linked to CLD, highlighting the need to perform regular aftercare visits to identify these changes. At a cellular level, conjunctival metaplasia and reduced goblet cell density have been linked to CLD, leading to a downstream effect on the tear film breakup time of contact lens wearers. These factors suggest a strong link between CLD and friction, raising the need to target this as a means of minimizing CLD. The purpose of this review is to identify the clinical signs that relate to CLD as a means of earlier detection and management in order to combat contact lens dropout. Keywords: contact lens discomfort, dry eye disease, lid wiper epitheliopathy, tear film biomarkers, meibomian gland dysfunction

  3. Forensic Analysis of a Contact Lens in a Murder Case.

    Science.gov (United States)

    Zwerling, Charles S

    2016-03-01

    Contact lenses have had rare relevance in trials and/or investigations. After 5 years of burial, orbital remnants were retrieved from an exhumed body and subsequently identified as a key piece of material evidence in a murder trial. The exhumed case materials were evaluated under laboratory conditions and were determined to be contact lens remnants. Contact lens fracture and burial simulation studies were performed to provide additional corroboration of the physical findings of the exhumed contact lens remnants. This material evidence was instrumental in providing factual proof refuting the defendant's testimony in the murder trial. A brief history of contact lens composition and use is provided for understanding the methods and observational results. This forensic case study represents the first published documentation of a contact lens from an exhumed body being used in a murder investigation and establishes an operational procedure for future forensic contact lens examinations. © 2016 American Academy of Forensic Sciences.

  4. Review on prevention of bacterial adhesion on contact lens using plasma treatment

    Science.gov (United States)

    Ramli, N. A. H.; Zaaba, S. K.; Mustaffa, M. T.; Zakaria, A.; Shahriman A., B.

    2017-03-01

    Many researches had been conducted to enhance the properties of contact lens. Most of the research conducted discussed on the factors that affect the adhesion process to contact lenses, rate of contact lens contamination, and type of microbe that adhere on the contact lens surface and contact lens casing. Studies on the proposed strategies or technology that can be used to slower down the formation of bacteria on contact lens are being explored. New technologies or strategies to prevent or slow down the adhesion of bacteria on contact lens have become a priority in this area. This review paper covers two main aspects, namely factor that affect the bacteria adhesion on contact lens and also the introduction of plasma treatment as a potential method for contact lens treatment.

  5. A study of corneal endothelial changes in soft contact lens wearers using non-contact specular microscopy

    Directory of Open Access Journals (Sweden)

    Renu M Magdum

    2013-01-01

    Full Text Available Aim: To study the corneal endothelial changes after soft contact lens wear, to correlate these changes with the duration of soft contact lens wear, and to study the pattern of use and preferences of contact lens among young adults. Materials and Methods: This observational study was carried out in 100 eyes of 50 soft contact lens users aged between 19 and 27 years. Both eyes of 50 medical students who had never worn contact lenses served as controls. Data from each subject were collected using a structured questionnaire of 24 items that included demographic profile, pattern of contact lens use, symptoms, brand name, number of years worn, and hours of daily wear. These data were analyzed using Chi square for association. Specular microscopy was done using TOPCON SP-3000P. Computerized morphometry was used to evaluate central corneal thickness, size, shape, mean cellular density, hexagonality, coefficient of variation, and polymegathism of the corneal cells . Results: It was found that central corneal thickness was 0.532 ± 0.0309 mm in lens users and 0.514 ± 0.03 mm in controls, cell density was 2570.91 ± 432.06 cells/mm 2 in lens users and 2723.17 ± 327.64 cells/mm 2 in controls, while hexagonality was 54.81 ± 39.72% in lens users and 67.65 ± 36.49% in controls. Conclusion: Despite the known effects of long duration of soft contact lens use on corneal endothelial cell morphology, this study could not draw a significant correlation between them. However, a significant difference was found in the corneal endothelial thickness, cell density, and hexagonality. Among the soft contact lens users, 62% used soft disposable type while 38% used soft extended wear contact lens. Contact lenses were preferred over spectacles for better cosmetic appearance, comfort, and wider visual field.

  6. Treatment of contact lens related dry eye with antibacterial honey.

    Science.gov (United States)

    Wong, Daniel; Albietz, Julie M; Tran, Huan; Du Toit, Cimonette; Li, Anita Hui; Yun, Tina; Han, Jee; Schmid, Katrina L

    2017-12-01

    Contact lens induced dry eye affects approximately 50% of contact lens wearers. The aim was to assess the effects of Manuka (Leptospermum sp.) honey eye drops (Optimel, Melcare, Australia) on dry eye in contact lens wearers. The safety of the honey eye drops in contact lens wear and contact lens wearers' compliance were also evaluated. Prospective, randomised, cross over study, examiner masked, pilot treatment trial. Twenty-four participants aged 20 to 55 years with contact lens related dry eye were recruited and randomised to two treatment groups; 20 completed the study. One group used Optimel eye drops twice a day for two weeks followed by conventional lubricant (Systane Ultra, Alcon) therapy for two weeks; the other group completed the treatments in the reverse order. Before and after each treatment dry eye symptomology, ocular surface inflammation, and tear quantity and quality were assessed. Participants completed a daily log detailing their usage of treatments and any issues. Dry eye symptoms improved significantly after Optimel treatment. Patients with more severe symptoms at baseline showed a greater improvement in symptoms. No significant differences were observed in the objective signs of dry eye; presumably because of the short treatment duration. Seventy-five% of contact lens wearers reported good adherence to Optimel treatment and 95% reported no issues using this product. Optimel Eye Drops reduce the symptoms of dry eye in contact lens wearers and are safe to use. A longer treatment period to assess the effect on clinical signs of dry eye is required. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  7. Gram negative bacteria and contact lens induced acute red eye

    Directory of Open Access Journals (Sweden)

    Sankaridurg Padmaja

    1996-01-01

    Full Text Available Two patients using hydrogel contact lenses on a daily wear schedule slept overnight with the lenses and woke up with a Contact Lens Induced Acute Red Eye (CLARE. The contact lenses recovered aseptically at the time of the event grew significant colonies of Pseudomonas aeruginosa and Aeromonas hydrophila in patient A and Pseudomonas aeruginosa and Serratia liquefaciens from patient B. Similar organisams from the contact lenses were recovered from the lens case and lens care solutions of patient B. In both the patients the condition resolved on discontinuation of lens wear. Patient compliance as a requirement for successful contact lens wear is highlighted with the illustration of these cases.

  8. Repertoire of free-living protozoa in contact lens solutions.

    Science.gov (United States)

    Bouchoucha, Ibtissem; Aziz, Aurore; Hoffart, Louis; Drancourt, Michel

    2016-10-29

    The repertoire of free-living protozoa in contact lens solutions is poorly known despite the fact that such protozoa may act as direct pathogens and may harbor intra-cellular pathogens. Between 2009 and 2014, the contact lens solutions collected from patients presenting at our Ophthalmology Department for clinically suspected keratitis, were cultured on non-nutrient agar examined by microscope for the presence of free-living protozoa. All protozoa were identified by 18S rRNA gene sequencing. A total of 20 of 233 (8.6 %) contact lens solution specimens collected from 16 patients were cultured. Acanthamoeba amoeba in 16 solutions (80 %) collected from 12 patients and Colpoda steini, Cercozoa sp., Protostelium sp. and a eukaryotic more closely related to Vermamoeba sp., were each isolated in one solution. Cercozoa sp., Colpoda sp., Protostelium sp. and Vermamoeba sp. are reported for the first time as contaminating contact lens solutions. The repertoire of protozoa in contact lens solutions is larger than previously known.

  9. Immunoglobulin Concentration in Tears of Contact Lens Wearers

    Science.gov (United States)

    Maurya, Rajendra P.; Bhushan, Prashant; Singh, Virendra P.; Singh, Mahendra K.; Kumar, Prakash; Bhatia, Ravindra P.S.; Singh, Usha

    2014-01-01

    Purpose: To evaluate changes in the concentration of tear immunoglobulins in contact lens wearers. Methods: A total of 45 cases including 23 contact lens wearers (43 eyes) and 22 age and sex matched healthy controls having no ocular pathology were studied for immunoglobulins (IgA, IgG, IgM) in their tears by single radial immunodiffusion method. Results: Most of the cases used soft (56.6%) and semi-soft gas permeable (30.4%) contact lenses. Tear IgM was detected in only 17.4% and tear IgG in 43.6% of contact lens wearers, while in controls IgG was detected in 9.1% but none of the controls had IgM. There was a significant rise in total tear IgA (13.17 ± 4.44 mg/dl) in contact lens wearer as compared to controls (8.93 ± 3.79 mg/dl). Rise of tear IgA was more in symptomatic patients (15.38 ± 5.28 mg/dl) and in those wearing hard (19.73 ± 5.43 mg/dl) and semi-soft contact lenses (13.31 ± 5.43 mg/dl). A significant increase in tear IgA was noticed in subjects wearing lenses for >3 years (15.69 ± 5.39 mg/dl). About 43.4% of lens wearers were symptomatic and 80% of their lenses showed deposits and/or haziness. All cases with IgM in tear were symptomatic. Conclusion: The relation of immunoglobulin concentration with increasing duration of wear and material of contact lens shows that tear immunoglobulin rise accrues due to mechanical stimulation, hence contact lenses should not be used for a long period and lenses of hard nature should be discouraged. The maintenance, cleaning and deproteinization of the lenses are of high importance to avoid immunostimulation. PMID:25667732

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... With Proper Contact Lens Care Apr 23, 2018 Solar Eclipse Inflicts Damage in the Shape of the ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human- ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but ... require the same level of care or consideration as a standard contact lens because they can be ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  15. Daily disposable contact lens prescribing around the world.

    Science.gov (United States)

    Efron, Nathan; Morgan, Philip B; Helland, Magne; Itoi, Motozumi; Jones, Deborah; Nichols, Jason J; van der Worp, Eef; Woods, Craig A

    2010-10-01

    Daily disposable contact lenses were introduced into the market 16 years ago. Data that we have gathered from annual contact lens fitting surveys conducted in Australia, Canada, Japan, The Netherlands, Norway, the UK and the USA between 2000 and 2008 indicates an overall increase in daily disposable lens fitting during this period. Daily disposable lenses are especially popular in Japan, Norway and the UK. There is a trend for these lenses to be fitted on a part-time basis. Males are over-represented in daily disposable lens fitting-a trend that is especially evident in Canada. Daily disposable lens wearers are about two years younger than wearers of reusable lenses in Japan and The Netherlands. The convenience and health benefits of daily disposable lenses are expected to fuel continued growth in this sector. Copyright (c) 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Clinical study of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes

    Directory of Open Access Journals (Sweden)

    Ru-Fa Meng

    2015-07-01

    Full Text Available AIM: To investigate the operation methods and clinical effects of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes.METHODS: During January 2012 to January 2014, foldable intraocular lens was implanted on 47 cases following lens-vitrectomy in residual capsular with traumatic eyes 3~6mo. Follow-up period was 6~12mo, averaged(8.21±2.63mo. RESULTS:All of 47 eyes had successful operation at one time, and position deviation was not appeared. The naked vision of the last postoperative follow-up was(0.44±0.19. Compared with best corrected visual acuity(0.41±0.23, and There was no significant difference between visual acuity of preoperative and last follow-up period(t=0.879, P=0.342. No severe complication was found. CONCLUSION: Secondary implantation of foldable intraocular lens is a safe and reliable method for correcting ametropia after lens-vitrectomy in residual capsular with traumatic eyes.

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... valid prescription that includes the brand name, lens measurements, and expiration date. Purchase the colored contact lenses ... with human-made versions. U.S. News Highlights the Value of Ophthalmologists APR 20, 2018 By Dan T. ...

  18. Controlled delivery of pirfenidone through vitamin E-loaded contact lens ameliorates corneal inflammation.

    Science.gov (United States)

    Dixon, Phillip; Ghosh, Tanushri; Mondal, Kalyani; Konar, Aditya; Chauhan, Anuj; Hazra, Sarbani

    2018-06-01

    Chemical injury by alkali burn is a major cause of corneal blindness in the clinical setting. Current management advocates multiple therapies aimed to prevent inflammation, initiate quick re-epithelialization, arrest the fibrosis, and avoid dry eye and pain by using bandage contact lenses. We hypothesized sustained delivery of the anti-inflammatory, antifibrotic drug pirfenidone through vitamin E-loaded contact lenses as a logical single approach to counter the pathology involved. Vitamin E particles were created in situ in commercial silicon hydrogel contact lenses by soaking the lenses in a vitamin E-ethanol solution. The vitamin E-laden lenses were then placed into pirfenidone-saline solution to load the drug into the lens. The contact lenses were evaluated by both in vitro and in vivo means. For in vitro, lenses were placed into 3 mL of saline solution. The concentration of pirfenidone released was measured by UV-vis spectrophotometry. The contact lenses were implanted in rabbit eyes following the alkali burn; the drug availability in the aqueous humor was evaluated by HPLC at various time points 10 min, 30 min, 2 h, and 3 h; and gene expression of inflammatory cytokines IL-1β, TNF-α, and TGF-β1 was evaluated in the cornea at the end of the study period. In another group of rabbits inflicted with alkali injury, the corneas were graded after 7 days of contact lens implantation with and without pirfenidone. A mathematical model was developed for delivery of the drug to the cornea and aqueous humor after a contact lens is inserted in the eye. The model was validated with experimental data and used to determine the bioavailability both for contact lenses and eye drops. In vitro release of unmodified commercial contact lenses saw a release time of approximately 20 min, with a partition coefficient of 2.68 ± 0.06. The release of pirfenidone from 20% vitamin E-loaded lenses saw a release time of approximately 80 min, with a partition coefficient of 4

  19. Severe pigment dispersion after iris-claw phakic intraocular lens implantation.

    Science.gov (United States)

    Galvis, Virgilio; Carreño, Néstor I; Tello, Alejandro; Laiton, Andrea N

    2017-12-01

    A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  20. Severe pigment dispersion after iris-claw phakic intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Virgilio Galvis

    2017-01-01

    Full Text Available A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  2. Citation parameters of contact lens-related articles published in the ophthalmic literature.

    Science.gov (United States)

    Cardona, Genís; Sanz, Joan P

    2014-09-01

    This study aimed at exploring the citation parameters of contact lenses articles published in the Ophthalmology thematic category of the Journal Citation Reports (JCR). The Thompson Reuters Web of Science database was accessed to record bibliometric information and citation parameters of all journals listed under the Ophthalmology area of the 2011 JCR edition, including the journals with main publication interests in the contact lens field. In addition, the same database was used to unveil all contact lens-related articles published in 2011 in the same thematic area, whereupon differences in citation parameters between those articles published in contact lens and non-contact lens-related journals were explored. Significant differences in some bibliometric indicators such as half-life and overall citation count were found between contact lens-related journals (shorter half-life and fewer citations) and the median values for the Ophthalmology thematic area of the JCR. Visual examination of all Ophthalmology journals uncovered a total of 156 contact lens-related articles, published in 28 different journals, with 27 articles each for Contact Lens & Anterior Eye, Eye & Contact Lens, and Optometry and Vision Science. Significant differences in citation parameters were encountered between those articles published in contact lens and non-contact lens source journals. These findings, which disclosed contact lenses to be a fertile area of research, may be of interest to researchers and institutions. Differences in bibliometric indicators are of relevance to avoid unwanted bias when conducting between- and within-discipline comparisons of articles, journals, and researchers.

  3. Acanthamoeba keratitis in Scotland: risk factors for contact lens wearers.

    Science.gov (United States)

    Seal, D V; Kirkness, C M; Bennett, H G; Peterson, M

    1999-01-01

    To investigate risk factors for Acanthamoeba keratitis amongst contact lens wearers in Scotland. Patients with Acanthamoeba keratitis in the Scottish study, all of whom wore contact lenses, were compared with 46 healthy asymptomatic contact lens-wearing controls. They were all visited at home for contact lens and environmental microbiological sampling. In addition, all 288 optical practices in the West of Scotland were polled for contact lens types and disinfecting solutions sold in 1995, and a sample, each of whom fitted more than 500 contact lenses per year, were polled for a second time. Independently, a poll was commissioned by the Eyecare Information Service in July/August 1995 to estimate the numbers of contact lens wearers in Scotland and the UK. Industry was polled for numbers of each contact lens disinfecting regimen sold in Scotland in 1995. West of Scotland, UK. All contact lens wearers among the 3 million population of the West of Scotland Health Board Areas. Risk factors for Acanthamoeba infection and recommendations for its prevention. When Acanthamoeba infection occurred, patients' home water systems were frequently (54%) found to be colonised by this amoeba. Patients more frequently washed their storage cases in tap water than controls (Pmethods (chlorine tablets or no disinfection). However further investigation showed that these methods were associated with an increased probability of rinsing the storage case in tap water, so that these two behaviours are confounded in the group studied. Failure to disinfect contact lenses, non-compliant use of chlorine tablets and/or introduction of tap water rinsing of storage cases were associated with increased risk of Acanthamoeba infection. New multipurpose solutions and hydrogen peroxide gave the lowest risk of Acanthamoeba infection, with no statistically significant difference between them. Ionic high-water content (FDA group 4) contact lenses were at increased risk of being associated with Acanthamoeba

  4. Corneal ring infiltration in contact lens wearers

    Directory of Open Access Journals (Sweden)

    Seyed Ali Tabatabaei

    2017-01-01

    Full Text Available To report a case of atypical sterile ring infiltrates during wearing soft silicone hydrogel contact lens due to poor lens care. A 29-year-old woman presented with complaints of pain, redness, and morning discharge. She was wearing soft silicone hydrogel contact lens previously; her current symptoms began 1 week before presentation. On examination, best-corrected visual acuity was 20/40 in that eye. Slit-lamp examination revealed dense, ring-shaped infiltrate involving both the superficial and deep stromal layers with lucid interval to the limbus, edema of the epithelium, epithelial defect, and vascularization of the superior limbus. Cornea-specific in vivo laser confocal microscopy (Heidelberg Retina Tomograph 2 Rostock Cornea Module, HRT 2-RCM, Heidelberg Engineering GmbH, Dossenheim, Germany revealed Langerhans cells and no sign of Acanthamoeba or fungal features, using lid scraping and anti-inflammatory drops; her vision completely recovered. We reported an atypical case of a sterile corneal ring infiltrate associated with soft contact lens wearing; smear, culture, and confocal microscopy confirmed a sterile inflammatory reaction.

  5. The significance of oxygen during contact lens wear.

    Science.gov (United States)

    Papas, Eric B

    2014-12-01

    In order to establish the relevance of oxygen to contemporary contact lens practice, a review of the literature was conducted. The results indicate that there are a number of processes occurring in the normal healthy eye where oxygen is required and which are potentially affected by the presence of a contact lens. These activities appear to take place at all corneal levels, as well as at the limbus. Evidence from laboratory, clinical and modelling studies indicates that what constitutes normal oxygenation (normoxia) depends on, among other things, the physiological system under consideration, corneal location and the state of eye closure. This diversity is reflected in the wide range of minimum lens oxygen transmissibility (Dk/t) requirements that are present in a literature. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  6. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients.

    Science.gov (United States)

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-03-01

    To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Retrospective, noncomparable consecutive case series study. Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support.

  7. Increased resistance of contact lens related bacterial biofilms to antimicrobial activity of soft contact lens care solutions

    Science.gov (United States)

    Szczotka-Flynn, Loretta B.; Imamura, Yoshifumi; Chandra, Jyotsna; Yu, Changping; Mukherjee, Pranab K.; Pearlman, Eric; Ghannoum, Mahmoud A.

    2014-01-01

    PURPOSE To determine if clinical and reference strains of Pseudomonas aeruginosa, Serratia marcescens, and Staphylococcus aureus form biofilms on silicone hydrogel contact lenses, and ascertain antimicrobial activities of contact lens care solutions. METHODS Clinical and American Type Culture Collection (ATCC) reference strains of Pseudomonas aeruginosa, Serratia marcescens, and Staphylococcus aureus were incubated with lotrafilcon A lenses under conditions that facilitate biofilm formation. Biofilms were quantified by quantitative culturing (colony forming units, CFUs), and gross morphology and architecture were evaluated using scanning electron microscopy (SEM) and confocal microscopy. Susceptibilities of the planktonic and biofilm growth phases of the bacteria to five common multipurpose contact lens care solutions and one hydrogen peroxide care solution were assessed. RESULTS P. aeruginosa, S. marcescens, and S. aureus reference and clinical strains formed biofilms on lotrafilcon A silicone hydrogel contact lenses, as dense networks of cells arranged in multiple layers with visible extracellular matrix. The biofilms were resistant to commonly used biguanide preserved multipurpose care solutions. P. aeruginosa and S. aureus biofilms were susceptible to a hydrogen peroxide and a polyquaternium preserved care solution, whereas S. marcescens biofilm was resistant to a polyquaternium preserved care solution but susceptible to hydrogen peroxide disinfection. In contrast, the planktonic forms were always susceptible. CONCLUSIONS P. aeruginosa, S. marcescens, and S. aureus form biofilms on lotrafilcon A contact lenses, which in contrast to planktonic cells, are resistant to the antimicrobial activity of several soft contact lens care products. PMID:19654521

  8. Contact Lens-Induced Discomfort and Protein Changes in Tears.

    Science.gov (United States)

    Masoudi, Simin; Stapleton, Fiona Jane; Willcox, Mark Duncan Perry

    2016-08-01

    Ocular discomfort is among the main causes of contact lens wear discontinuation. This study investigated the association between subjective ocular comfort ratings and diurnal changes in tear protein concentrations with and without contact lens wear. The study was a prospective, open-label, single-group two-staged investigation. Basal tears were collected from 30 experienced contact lens wearers twice a day (morning and evening) using a noninvasive method without lens wear (stage 1) and during wear of Etafilcon A contact lenses (stage 2) for 7 to 10 days. Subjects rated their ocular comfort on a scale of 1 to 100 (with 100 as extremely comfortable) at each time of tear collection. Tears were analyzed using liquid quadrupole mass spectrometry in conjunction with selected reaction monitoring (SRM) method. End-of-day comfort was reduced when wearing lenses (87.8 ± 14.3 AM vs. 79.2 ± 16.6 PM) compared to no lens wear (88.3 ± 12.6 AM vs. 84.7 ± 13.3 PM) (AM vs. PM, p tears (p < 0.05, r = -0.29). Only the absolute concentration of prolactin-induced protein correlated with subjective comfort ratings. Taking into consideration that prolactin-induced protein can be associated with disruption in water transport in lacrimal glands, our findings may indicate that changes to aqueous secretion are associated with contact lens discomfort.

  9. [Pigment dispersion and Artisan implants: crystalline lens rise as a safety criterion].

    Science.gov (United States)

    Baikoff, G; Bourgeon, G; Jodai, H Jitsuo; Fontaine, A; Vieira Lellis, F; Trinquet, L

    2005-06-01

    To validate the theoretical notion of a crystalline lens rise as a safety criterion for ARTISAN implants in order to prevent the development of pigment dispersion in the implanted eye. Crystalline lens rise is defined by the distance between the crystalline lens's anterior pole and the horizontal plane joining the opposite iridocorneal recesses. We analyzed the biometric measurements of 87 eyes with an Artisan implant. A comparative analysis of the crystalline lens rise was carried out on the nine eyes having developed pigment dispersion and 78 eyes with no problems. Among the modern anterior segment imaging devices (Artemis, Scheimpflug photography, optical coherence tomography, radiology exploration, magnetic resonance imaging, TDM), an anterior chamber optical coherence tomography (AC-OCT) prototype was used. This working hypothesis was confirmed by this study: the crystalline lens rise must be considered as a new safety criterion for implanting Artisan phakic lenses. Indeed, the higher the crystalline lens's rise, the greater the risk of developing pigment dispersion in the pupil area. This complication is more frequent in hyperopes than in myopes. We can consider that there is little or no risk of pigment dispersion if the rise is below 600 microm; however, at 600 microm or greater, there is a 67% rate of pupillary pigment dispersion. In certain cases, when the implant was loosely fixed, there was no traction on the iris root. This is a complication that can be avoided or delayed. The crystalline lens rise must be part of new safety criteria to be taken into consideration when inserting an Artisan implant. This notion must also be applied to other types of phakic implants. The distance remaining between the crystalline lens rise and a 600-micromm theoretical safety level allows one to calculate a safety time interval.

  10. Cytokine changes in tears and relationship to contact lens discomfort.

    Science.gov (United States)

    Willcox, Mark D P; Zhao, Zhenjun; Naduvilath, Thomas; Lazon de la Jara, Percy

    2015-01-01

    To determine the reproducibility of a multiplex bead assay for measuring cytokines in tears and correlations between ocular discomfort with or without contact lens wear and the concentration of cytokines in tears. Ninety participants (divided into two groups) were enrolled in this prospective study. They were asked to rate their ocular comfort and collect their tears in the morning and just before sleep for 10 days with or without contact lenses. The participants collected their tears using a glass microcapillary tube for both stages. Galyfilcon A lenses were worn on a daily disposable basis during the contact lens stage, and comfort scores and tears were collected before lens insertion and prior to lens removal at the end of the day. Tears were analyzed for cytokine concentrations using a 27-plex multibead assay. Correlations were sought between cytokine concentrations and comfort. There was a significant (p-0.5 Log pg/ml, p-0.2 Log pg/ml, ptears was correlated to ocular comfort, but this was not changed by contact lens wear. Ocular comfort during the day is magnified by contact lens wear. However, the increase in the change in comfort during lens wear was not associated with changes in 15 cytokines in the tear film.

  11. Transient anterior subcapsular vacuolar change of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation.

    Science.gov (United States)

    Chung, Jin Kwon; Shin, Jin Hee; Lee, Sung Jin

    2013-10-25

    We present two cases of transient vacuolar changes in the anterior subcapsular space of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation. Implantable collamer lenses (ICL) were implanted in healthy myopic patients. Vacuolar changes developed just after the irrigating procedure through the narrow space between the ICL and the crystalline lens. Slit-lamp examinations and spectral domain optical coherence tomography showed bleb-like lesions in the anterior subcapsular space of one eye in each case, though the lesions gradually improved without visual deterioration. Consequently, the lesions turned into a few anterior subcapsular small faint opacities. Direct irrigation of the narrow space confined by the ICL and the crystalline lens is at risk for the development of vacuolar changes in the crystalline lens. The observed spontaneous reversal indicates that surgeons should not rush to surgical intervention but rather opt for close follow over several weeks.

  12. The safety and efficacy of contact lens wear in the industrial and chemical workplace.

    Science.gov (United States)

    Tyhurst, Keith; McNett, Ryan; Bennett, Edward

    2007-11-01

    The use and safety of contact lenses in the industrial and chemical workplace has often been questioned since the 1960s because of many unconfirmed reports of ocular injury resulting from contact lens wear. Because of these urban legends, contact lens wear has been banned or wearers have been required to wear additional personal protective equipment (PPE) not required of non-contact lens wearers. Literature review via Medline and Google search. Research has shown that contact lenses typically provide protective benefits that decrease the severity of ocular injury and improve worker performance. While contact lens wear contraindications do exist, in most cases, and with proper precautions, contact lens wear is still possible. Industrial and chemical companies need to establish written contact lens use policies based on current studies that have shown the safety of workplace contact lens wear when combined with the same PPE required of non-contact lens wearers. Practitioners need to discuss, with their contact lens patients, the additional responsibilities required to maintain proper lens hygiene and proper PPE in the workplace.

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  14. Retinal images in the human eye with implanted intraocular lens

    Science.gov (United States)

    Zając, Marek; Siedlecki, Damian; Nowak, Jerzy

    2007-04-01

    A typical proceeding in cataract is based on the removal of opaque crystalline lens and inserting in its place the artificial intraocular lens (IOL). The quality of retinal image after such procedure depends, among others, on the parameters of the IOL, so the design of the implanted lens is of great importance. An appropriate choice of the IOL material, especially in relation to its biocompatibility, is often considered. However the parameter, which is often omitted during the IOL design is its chromatic aberration. In particular lack of its adequacy to the chromatic aberration of a crystalline lens may cause problems. In order to fit better chromatic aberration of the eye with implanted IOL to that of the healthy eye we propose a hybrid - refractive-diffractive IOL. It can be designed in such way that the total longitudinal chromatic aberration of an eye with implanted IOL equals the total longitudinal chromatic aberration of a healthy eye. In this study we compare the retinal image quality calculated numerically on the basis of the well known Liou-Brennan eye model with typical IOL implanted with that obtained if the IOL is done as hybrid (refractive-diffractive) design.

  15. [Intraocular lens implantation with one loop haptic amputated: a new propose to the subluxation lens surgical treatment].

    Science.gov (United States)

    Ventura, Marcelo; Endriss, Daniela

    2010-01-01

    To evaluate the postoperative results of congenital lens subluxation corrected by a new technique. Retrospective chart review of 21 eyes of 13 patients with no traumatic lens subluxation who underwent surgery in Altino Ventura Foundation from April, 1999 to April, 2004. The mean age was 8.7 +/- 5.4 years old, and the mean follow-up period was 21.5 +/- 19.3 months. Patients underwent phacoaspiration, endocapsular ring and intraocular lens (IOL) implantation. The implanted IOL had one loop haptic excised and was supported above the ring, inside the capsular bag promoting intraocular lens centralization. Visual acuity improvement was observed in all cases. There was a significant reduction of the spherical equivalent and spherical component comparing the pre and postoperative refraction (psubluxation surgical treatment, promoting lens centralization and postoperative visual acuity improvement.

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into ...

  17. Bacterial Adhesion Forces to Ag-Impregnated Contact Lens Cases and Transmission to Contact Lenses

    NARCIS (Netherlands)

    Qu, Wenwen; Busscher, Henk J.; van der Mei, Henny C.; Hooymans, Johanna M. M.

    Purpose: To measure adhesion forces of Pseudomonas aeruginosa, Staphylococcus aureus, and Serratia marcescens to a rigid contact lens (CL), standard polypropylene, and Ag-impregnated lens cases using atomic force microscopy and determine bacterial transmission from lens case to CL. Methods: Adhesion

  18. The Risk of Contact Lens Wear and the Avoidance of Complications

    Directory of Open Access Journals (Sweden)

    Farihah Tariq

    2013-11-01

    Full Text Available Contact lenses are lenses placed on the surface of the cornea to correct refractive errors such as myopia (short-sightedness, hypermetropia (far-sightedness and astigmatism. Lens-related complications are becoming a greater health concern as increasing number of individuals are using them as an alternative to spectacles. Contact lenses alter the natural ocular environment and reduce the efficacy of the innate defences. Although many complications are minor, microbial keratitis is potentially blinding and suspected cases should be rapidly diagnosed and referred to an ophthalmologist for treatment. Several risk factors have been identified with extended wear, poor hand hygiene, inadequate lens and lens-case care being the most significant. Promotion of good contact lens hygiene and practices are essential to reduce the adverse effects of contact lens wear.

  19. Goldmann applanation tonometry over daily disposable contact lens: accuracy and safety of procedure.

    Science.gov (United States)

    Zeri, Fabrizio; Lupelli, Luigi; Formichella, Paolo; Masci, Carlo; Fletcher, Robert

    2007-09-01

    To study accuracy and safety, related to sensation (discomfort) and trauma, when using Goldmann applanation tonometry (GAT) on eyes wearing daily disposable soft contact lenses. The intra-ocular pressure (IOP) of 136 normal eyes of 68 subjects was measured by Goldmann tonometer. Measurements were made in one eye with a contact lens (hilafilcon A) without anaesthetic drops and then without the contact lens using one drop of 0.4% oxybuprocaine hydrochloride. Each contact lens used was identical as to back optic zone, back vertex power. Standard Goldmann procedure only was used for the fellow eye of each subject. Subjective sensation (discomfort) responses to both procedures were studied in a subgroup (66 eyes) using a scale of discomfort, from 1 (no sensation) to 5 (highest sensation). Epithelial staining after tonometry was evaluated for this subgroup. No significant differences were found for the IOP with and without contact lens (tcontact lens insertion, tonometry on contact lens and application of topical anaesthetic). Corneal epithelial staining following the standard tonometry procedure was significantly higher than following the procedure with a contact lens (pcontact lens is accurate, compared to the standard procedure and within the IOP's normal range studied here. Also using a contact lens results in less trauma whilst discomfort is similar.

  20. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  1. Phacoemulsification and intraocular lens implantation in patients with oculocutaneous albinism.

    Science.gov (United States)

    Dávila, Pedro J; Ulloa-Padilla, Jan P; Izquierdo, Natalio J

    2017-01-01

    To evaluate the benefits of phacoemulsification and intraocular lens implantation in patients with oculocutaneous albinism (OCA). The charts of 195 patients with OCA who visited a local eye clinic were reviewed. All of these patients had genetic linkage analysis to establish OCA type. Frequencies and Paired t-test analysis were determined. Of the 195 patients, nine (4.6%) underwent clear cornea phacoemulsification with intraocular lens implantation. Seven of the nine patients with OCA had the Hermansky-Pudlak (HPS) type 1; two had OCA type 1. Pre-operative BCVA of all eyes ranged from 1.0 to 2.3 logMAR with a mean of 1.42 logMAR and a standard deviation of 0.41 logMAR. Post-operative BCVA of all eyes ranged from 1.0 to 1.30 logMAR with a mean of 1.04 logMAR and a standard deviation of 0.10 logMAR. BCVA improved after phacoemulsification surgery and intraocular lens implantation (p = 0.002). Pre-operative astigmatism of all eyes ranged from +0.50 to +5.75 with a mean of +2.25 and a standard deviation of +2.40. Post-operative astigmatism of all eyes ranged from +0.50 to +2.00 with a mean of +1.23 and a standard deviation of +0.42. Astigmatism improved after phacoemulsification surgery and intraocular lens implantation (p = 0.05). Nine patients with OCA who underwent phacoemulsification and intraocular lens implant experienced improved visual acuity and reduced astigmatism post-operatively. These results suggest cataract surgery may improve vision and refractive errors, and thus quality of life, in patients with albinism.

  2. Fixed mydriatic pupil associated with an intraocular pressure rise as a complication of the implant of a Phakic Refractive Lens (PRL).

    Science.gov (United States)

    Pérez-Cambrodí, Rafael José; Piñero-Llorens, David Pablo; Ruiz-Fortes, Juan Pedro; Blanes-Mompó, Francisco Javier; Cerviño-Expósito, Alejandro

    2014-07-01

    We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.

  3. Accidental injections of dexamethasone intravitreal implant (Ozurdex) into the crystalline lens.

    Science.gov (United States)

    Coca-Robinot, Javier; Casco-Silva, Bruno; Armadá-Maresca, Felix; García-Martínez, Jesús

    2014-01-01

    To describe the side effects and management after inadvertent injection of a dexamethasone implant (Ozurdex) into the crystalline lens. Two case reports. Two patients with macular edema due to unilateral retinal vein occlusion were scheduled for an intravitreal injection of Ozurdex. During the procedure, the implant was accidentally injected into the crystalline lens. Both patients developed cataracts during the course of several weeks and in both there was an intraocular pressure (IOP) increase, which required treatment with topical hypotensives. Macular edema improved only slightly. Cataract surgery with uneventful removal of the implant was performed 3 (case 1) and 6 months (case 2) after the injection. After inadvertent injection of Ozurdex into the crystalline lens, cataract surgery with removal of the implant should be performed as soon as possible in order to avoid IOP increase and so that the underlying condition may be treated adequately.

  4. Disposable contact lens use as a risk factor for microbial keratitis

    OpenAIRE

    Radford, C.; Minassian, D.; Dart, J.

    1998-01-01

    AIMS—A case-control study was performed to evaluate soft contact lens (SCL) wear modality as a risk factor for microbial keratitis.
METHODS—Contact lens wearers presenting as new patients to Moorfields Eye Hospital accident and emergency department during a 12 month period completed a self administered questionnaire detailing demographic data and contact lens use habits. Cases were patients with a clinical diagnosis of SCL related microbial keratitis. Controls were SCL users attending with di...

  5. Dark secrets behind the shimmer of contact lens: the Indian scenario

    Directory of Open Access Journals (Sweden)

    Singh Deepak

    2009-05-01

    Full Text Available Abstract Background We studied the bacteriological profile of soft contact lens and its accessories among the asymptomatic subjects and monitored the compliance level with the lens use and its cleaning protocol. Findings A total of 115 (104 daily wear and 11 extended wear subjects using contact lens were studied. Data regarding the duration of use and frequency and method of cleaning were recorded. Contact lens, lens cases, preserving solutions and tips of solution bottles were the samples collected. The isolates were identified on the basis of their phenotypic characters. Samples from 24 subjects (21 daily wear and 3 extended wear were found contaminated. Of the 24 contaminated cases, 23 showed medium adherence to the cleaning protocol. Contamination rate was higher among the 56 daily wear lens users who used same lens for 2 years and more, than the 48 users who used their lenses for less than 2 years. Lens case contamination was found in all the 24 cases. The bacteria isolated were Citrobacter freundii, Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Staphylococcus epidermidis and Streptococcus pneumoniae. In extended wear lens users, there was no change in microbial flora on repeating the cultures on day 7 and 14. Conclusion Non-compliance with contact lens use may lead to invitation of microbial flora. The accumulation of these bacteria may act as a precursor to biofilm formation, thus colonizing the lens accessories as well. The bacteria isolated in this study were similar to the ones causing microbial keratitis thus, predisposing the otherwise asymptomatic subjects to permanent visual damage.

  6. Measurement accuracy of a stressed contact lens during its relaxation period

    Science.gov (United States)

    Compertore, David C.; Ignatovich, Filipp V.

    2018-02-01

    We examine the dioptric power and transmitted wavefront of a contact lens as it releases its handling stresses. Handling stresses are introduced as part of the contact lens loading process and are common across all contact lens measurement procedures and systems. The latest advances in vision correction require tighter quality control during the manufacturing of the contact lenses. The optical power of contact lenses is one of the critical characteristics for users. Power measurements are conducted in the hydrated state, where the lens is resting inside a solution-filled glass cuvette. In a typical approach, the contact lens must be subject to long settling times prior to any measurements. Alternatively, multiple measurements must be averaged. Apart from potential operator dependency of such approach, it is extremely time-consuming, and therefore it precludes higher rates of testing. Comprehensive knowledge about the settling process can be obtained by monitoring multiple parameters of the lens simultaneously. We have developed a system that combines co-aligned a Shack-Hartmann transmitted wavefront sensor and a time-domain low coherence interferometer to measure several optical and physical parameters (power, cylinder power, aberrations, center thickness, sagittal depth, and diameter) simultaneously. We monitor these parameters during the stress relaxation period and show correlations that can be used by manufacturers to devise methods for improved quality control procedures.

  7. Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction

    Directory of Open Access Journals (Sweden)

    Santiago García-Lázaro

    2014-04-01

    Full Text Available Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA, binocular near visual acuity (BNVA, defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA were measured under photopic conditions (85 cd/m2. Moreover, BDVA and binocular distance contrast sensitivity were examined under mesopic conditions (5 cd/m2. Results: Visual acuity at an intermediate distance and near vision was better with the CBMCLC than with the artificial pupil (p<0.05. Statistically significant differences were found in contrast sensitivity between the two types of correction for distance (under mesopic conditions and for near vision, with the CBMCLC exhibiting better results in both cases (p<0.05. The mean NSA values obtained for the artificial pupil contact lens were significantly worse than those for the CBMCLC (p=0.001. Conclusion: The CBMCLC provided greater visual performance in terms of intermediate and near vision compared with the artificial pupil contact lens.

  8. Treatment, material, care, and patient-related factors in contact lens-related dry eye.

    Science.gov (United States)

    Ramamoorthy, Padmapriya; Sinnott, Loraine T; Nichols, Jason J

    2008-08-01

    To examine the effect of general contact lens and material characteristics, care solutions, treatment, and patient-related factors on contact lens-related dry eye. The data were derived from the Contact Lens and Dry Eye Study, designed as a cross-sectional and nested case-control study including 360 subjects. In separate statistical models, logistic regression was used to examine general contact lens characteristics, specific hydrogel lens materials, care solutions, and patient-related factors associated with dry eye status (controlled for age, gender, and current treatments). Several factors were significantly associated with dry eye, including treatment factors such as a recent contact lens refitting (odds ratios [OR] = 5.75, 95% confidence intervals [CI] = 2.14 to 15.46) and use of artificial tears/rewetting drops (OR = 1.09, 95% CI = 1.02 to 1.16), in addition, currently worn materials including Food and Drug Administration (FDA) group II (OR = 2.98, 95% CI = 1.14 to 6.19) and IV (OR = 1.87, 95% CI = 1.08 to 3.24). Significant patient-related factors included decreased overall satisfaction (OR = 3.57, 95% CI = 2.08 to 5.88,), dry eye in the absence of contact lens wear (OR = 6.54, 95% CI = 2.57 to 16.62), reduced daily lens wear duration (OR = 1.16, 95% CI = 1.06 to 1.26), and reduced ability to wear lenses as long as desired (OR = 2.44, 95% CI = 1.30 to 4.54). Care solutions were not associated with contact lens-related dry eye. The strong association of common treatment factors with dry eye status in contact lens wearers suggests that these treatments are not entirely effective. The use of high water content materials was strongly related to dry eye in lens wearers, whereas care solutions were not. Contact lens-related dry eye was also associated with several patient-related factors such as greater ocular discomfort (without lenses), dissatisfaction, and inability to wear lenses for desired durations.

  9. Corneal confocal microscopy and dry eye findings in contact lens discomfort patients.

    Science.gov (United States)

    Dogan, Aysun Sanal; Gurdal, Canan; Arslan, Nese

    2018-02-01

    To evaluate the corneal confocal microscopy and dry eye findings in patients with contact lens discomfort. The study included 3 groups of participants: Contact lens wearers using silicone hydrogel soft contact lenses who are symptomatic (CLD, n=15) or asymptomatic (ACL, n=11) and non-wearers as controls (n=14). Duration of contact lens wear, Ocular Surface Disease Index (OSDI) questionnaire responses, fluorescein tear break-uptime (FBUT), and corneal confocal microscopy findings were recorded. Mean age was 25.7±8.2 years and male/female ratio was 7/33. Demographic findings were similar regarding the groups. CLD patients had a longer lens use history than ACL (median 5 vs 2 years, pCLD group than ACL or controls (pCLD group, compared to controls and ACL (pCLD group compared to controls but similar to ACL (pCLD group than the ACL (p=0.014). Patients with CLD had been wearing contact lenses for longer than those without symptoms. OSDI and FBUT scores were worse in CLD patients. In contact lens discomfort patients, there were increased dendritiform cells, indicating intensified inflammatory status of the cornea. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  10. Original Article Effect of Soft Contact Lens Materials on Tear Film ...

    African Journals Online (AJOL)

    problems, results in intolerance of contact lens wear and damage (Foulks, ... reported that contact lens-related dry eye may be ... eliminating or modifying the refractive error ..... risk of eye infection, easier handling due to ... Adv Exp Med Biol.

  11. Clinical Presentation and Antibiotic Susceptibility of Contact Lens Associated Microbial Keratitis

    Directory of Open Access Journals (Sweden)

    Hesam Hedayati

    2015-01-01

    Full Text Available Introduction. In recent years, the number of contact lens wearers has dramatically increased in Iran, particularly in youngsters. The purpose of current study was to assess the clinical presentation and antibiotic susceptibility of contact lens related microbial keratitis in Ahvaz, southwest of Iran. Methodology. A cross-sectional investigation of 26 patients (33 eyes with contact lens induced corneal ulcers who were admitted to Imam Khomeini Hospital, Ahwaz City, from June 2012 to June 2013 was done. In order to study microbial culture and susceptibility of corneal ulcers, all of them were scraped. Results. Eight samples were reported as sterile. Pseudomonas aeruginosa (80% in positive cultures was the most widely recognized causative organism isolated. This is followed by Staphylococcus aureus 12% and Enterobacter 8%. The results showed that 84% of the microorganism cases were sensitive to ciprofloxacin, while imipenem, meropenem, and ceftazidime were the second most effective antibiotics (76%. Conclusion. Results of current study show the importance of referring all contact lens wearers with suspected corneal infection to ophthalmologists for more cure. The corneal scraping culture and contact lens solution should be performed to guide antibiotic therapy.

  12. Effect of implanted doses of N+-ions on the contact resistance of copper contacts

    International Nuclear Information System (INIS)

    Dubravec, B.; Kovac, P.; Lipka, F.; Padysak, M.

    1997-01-01

    The paper deals with the effect of implanted doses of N + ions on the contact resistance. Dependencies of the contact resistance versus contact force R c =f(F c ) and microhardness of implanted surfaces were measured for three implanted profiles. The influence of the aggressive environs on the contact resistance of implanted contact is given too

  13. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Clinical research on high oxygen permeable contact lens used after photorefractive keratectomy surgery

    Directory of Open Access Journals (Sweden)

    Hao-Jiang Yang

    2013-07-01

    Full Text Available AIM: To evaluate the outcome of high oxygen permeable contact lens used after photorefractive keratectomy(PRKsurgery.METHODS: Totally 95 patients(190 eyesafter PRK were included. Patients were randomly assigned to wear high oxygen permeable contact lens in one eye and normal lens in the fellow eye after surgery. The subjective symptoms and corneal epithelial status after PRK were evaluated. Uncorrected visual acuity(UCVAand haze were assessed at 6 months after PRK.RESULTS: Complaints of blurred vision, pain and photophobia were statistically more among the normal lens group than high oxygen permeable contact lens group(PPP=0.35. There was no difference in UCVA and haze 6 months after surgery(P=0.55. CONCLUSION: High oxygen permeable contact lens can significantly produce less the corneal irritated symptoms, reduce the discomfort feeling and promote healing of corneal epithelium after PRK.

  15. Compliance and hygiene behaviour among soft contact lens wearers in the Maldives.

    Science.gov (United States)

    Gyawali, Rajendra; Nestha Mohamed, Fathimath; Bist, Jeewanand; Kandel, Himal; Marasini, Sanjay; Khadka, Jyoti

    2014-01-01

    Significant levels of non-compliance and poor hygiene among contact lens wearers have been reported previously from different parts of the world. This survey aimed at identifying the scope of hygiene and non-compliant behaviour of soft contact lens wearers in the Maldives. Established soft lens wearers attending two eye clinics in Male' city, were interviewed in office or via telephone. A set of interviewer-administered questions was used to access the subjective response on compliance and hygiene behaviour (hand and lens case hygiene, water exposure, adherence to lens replacement schedule, dozing and overnight wear, awareness of aftercare visits and reuse of disinfecting solution). Participants were also asked to rate themselves as a contact lens user based on their perceived compliance and hygiene practices. Out of 107 participants, 79 (74.8 per cent) were interviewed in the office and the rest via telephone. The majority of lens wearers were female, office workers and students, with a mean age of 20.64 ± 4.4 years. Mean duration of lens wear was 28.04 ± 8.36 months. Most of them were using spherical lenses (86.9 per cent) on a daily wear basis (96.3 per cent). Major reported forms of non-compliance were poor hand hygiene (60.7 per cent), lack of aftercare awareness (39.3 per cent), water exposure (35.5 per cent) and over-use of lenses (24.3 per cent). While females were more likely to overuse their lenses than males (p hygienic behaviour. A significant number of Maldivian contact lens wearers exhibited poor levels of hygiene and compliance with contact lenses and lens care systems. An effective educational reinforcement strategy needs to be developed to modify lens wearers' non-compliance. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  16. the level of contact lens practice in port harcourt, rivers state of ...

    African Journals Online (AJOL)

    LIVINGSTON

    routine optometric examination- keratometer, slit lamp biomicroscope, retinoscope, trial case, and diagnostic contact lenses. For diagnostic contact lenses, the practitioner can confine himself to just a few lens types . A successful contact lens practice would involve astute practice management. Type of practice to be offered ...

  17. A bandage contact lens prevents extrusion of ocular contents.

    Science.gov (United States)

    Ramjiani, Vipul; Fearnley, Thomas; Tan, Jennifer

    2016-02-01

    A 76 year old male presents with a corneal perforation in a phthisical eye. Definitive treatment in the form of an evisceration was delayed by 38 days. During this period a bandage contact lens prevented extrusion of ocular contents through an enlarging corneal perforation. This case demonstrates that a bandage contact lens can be effective in the immediate management of large corneal perforations whilst awaiting urgent definitive treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Pseudomonas aeruginosa Survival at Posterior Contact Lens Surfaces after Daily Wear

    Science.gov (United States)

    Wu, Yvonne T.; Zhu, Lucia S.; Tam, K. P. Connie; Evans, David J.; Fleiszig, Suzanne M. J.

    2015-01-01

    Purpose Pseudomonas aeruginosa keratitis is a sight-threatening complication of contact lens wear, yet mechanisms by which lenses predispose to infection remain unclear. Here, we tested the hypothesis that tear fluid at the posterior contact lens surface can lose antimicrobial activity over time during lens wear. Methods Daily disposable lenses were worn for 1, 2, 4, 6 or 8 h immediately after removal from their packaging, or after presoaking in sterile saline for 2 days to remove packaging solution. Unworn lenses were also tested, some coated in tears “aged” in vitro for 1 or 8 h. Lenses were placed anterior surface down into tryptic soy agar cradles containing gentamicin (100µg/ml) to kill bacteria already on the lens, and posterior surfaces inoculated with gentamicin-resistant P. aeruginosa for 3 h. Surviving bacteria were enumerated by viable counts of lens homogenates. Results Posterior surfaces of lenses worn by patients for 8 h supported more P. aeruginosa growth than lenses worn for only 1 h, if lenses were presoaked prior to wear (~ 2.4-fold, p = 0.01). This increase was offset if lenses were not presoaked to remove packaging solution (p = 0.04 at 2 h and 4 h). Irrespective of presoaking, lenses worn for 8 h showed more growth on their posterior surface than unworn lenses coated with tear fluid that was “aged” for 8 h vitro (~8.6-fold, presoaked, p = 0.003: ~ 5.4-fold from packaging solution, p = 0.004). Indeed, in vitro incubation did not impact tear antimicrobial activity. Conclusions This study shows that post lens tear fluid can lose antimicrobial activity over time during contact lens wear, supporting the idea that efficient tear exchange under a lens is critical for homeostasis. Additional studies are needed to determine applicability to other lens types, wearing modalities, and relevance to contact lens-related infections. PMID:25955639

  19. Acanthamoeba keratitis in a non-contact lens wearer with human immunodeficiency virus

    DEFF Research Database (Denmark)

    Hansen, Birgitte Rønde; Kronborg, Gitte

    2003-01-01

    , and was treated with various topical antibiotics and steroids. 13 months after symptom onset the eye was removed owing to serious scarring of cornea and unbearable pain. Microbiological and histopathological examination of the cornea showed Acanthamoeba. In non-contact lens wearers suffering from Acanthamoeba......Acanthamoeba keratitis is potentially blinding and often associated with contact lens wearing. A human immunodeficiency virus (HIV)-positive patient, a non-contact lens wearer, presented with keratitis. She experienced a protracted course of disease, characterized by exacerbations and remissions...

  20. Cell adhesion of F{sup +} ion implantation of intraocular lens

    Energy Technology Data Exchange (ETDEWEB)

    Li, D.J. E-mail: dejunli@hotmail.com; Cui, F.Z.; Gu, H.Q

    1999-04-01

    The cell adhesion of ion implanted polymethylmethacrylate (PMMA) intraocular lens was studied using cultured cells in vitro. F{sup +} ion implantation was performed at the energies of 40, 60, 80, 100 keV with the fluences ranging from 5x10{sup 13} to 1x10{sup 15} ions/cm{sup 2} at room temperature. The cell adhesion tests gave interesting results that the number of the neutral granulocytes and the macrophages adhering on surface were reduced significantly after ion implantation. The optimal fluence was about 4x10{sup 14} ions/cm{sup 2}. The hydrophobicity imparted to the lens surface was also enhanced. The results of X-ray photoelectron spectroscopy analysis indicated that ion implantation resulted in the cleavage of some pendant groups, the oxidation of the surface, and the formation of some new chemical bonds, which was probably the main reason for the cell adhesion change.

  1. Pseudophakodonesis and corneal endothelial contact: direct observations by high-speed cinematography.

    Science.gov (United States)

    Jacobs, P M; Cheng, H; Price, N C

    1983-10-01

    High-speed cinematography was used to observe the movement of Federov type I lens implants within the anterior chamber. Our measurements suggest that in most patients contact between the lens implant and corneal endothelium does not occur.

  2. Bacterial transmission from lens storage cases to contact lenses - Effects of lens care solutions and silver impregnation of cases

    NARCIS (Netherlands)

    Vermeltfoort, Pit B. J.; Hooymans, Johanna M. M.; Busscher, Henk J.; van der Mei, Henny C.

    2008-01-01

    The killing efficacies of multipurpose lens care solutions on planktonic and biofilm bacteria grown in polypropylene contact lens storage cases with and without silver impregnation and effects on bacterial transmission from storage cases to silicone hydrogel contact lenses were investigated. For

  3. Management and treatment of contact lens-related Pseudomonas keratitis

    Directory of Open Access Journals (Sweden)

    Willcox MD

    2012-06-01

    Full Text Available Mark DP WillcoxSchool of Optometry and Vision Science, University of New South Wales, Sydney, AustraliaAbstract: Pubmed and Medline were searched for articles referring to Pseudomonas keratitis between the years 2007 and 2012 to obtain an overview of the current state of this disease. Keyword searches used the terms "Pseudomonas" + "Keratitis" limit to "2007–2012", and ["Ulcerative" or "Microbial"] + "Keratitis" + "Contact lenses" limit to "2007–2012". These articles were then reviewed for information on the percentage of microbial keratitis cases associated with contact lens wear, the frequency of Pseudomonas sp. as a causative agent of microbial keratitis around the world, the most common therapies to treat Pseudomonas keratitis, and the sensitivity of isolates of Pseudomonas to commonly prescribed antibiotics. The percentage of microbial keratitis associated with contact lens wear ranged from 0% in a study from Nepal to 54.5% from Japan. These differences may be due in part to different frequencies of contact lens wear. The frequency of Pseudomonas sp. as a causative agent of keratitis ranged from 1% in Japan to over 50% in studies from India, Malaysia, and Thailand. The most commonly reported agents used to treat Pseudomonas keratitis were either aminoglycoside (usually gentamicin fortified with a cephalosporin, or monotherapy with a fluoroquinolone (usually ciprofloxacin. In most geographical areas, most strains of Pseudomonas sp. (≥95% were sensitive to ciprofloxacin, but reports from India, Nigeria, and Thailand reported sensitivity to this antibiotic and similar fluoroquinolones of between 76% and 90%.Keywords: Pseudomonas, keratitis, contact lens

  4. Steady-State Diffusion of Water through Soft-Contact LensMaterials

    Energy Technology Data Exchange (ETDEWEB)

    Fornasiero, Francesco; Krull, Florian; Radke, Clayton J.; Prausnitz, JohnM.

    2005-01-31

    Water transport through soft contact lenses (SCL) is important for acceptable performance on the human eye. Chemical-potential gradient-driven diffusion rates of water through soft-contact-lens materials are measured with an evaporation-cell technique. Water is evaporated from the bottom surface of a lens membrane by impinging air at controlled flow rate and humidity. The resulting weight loss of a water reservoir covering the top surface of the contact-lens material is recorded as a function of time. New results are reported for a conventional hydrogel material (SofLens{trademark} One Day, hilafilcon A, water content at saturation W{sub 10} = 70 weight %) and a silicone hydrogel material (PureVision{trademark}, balafilcon A, W{sub 10} = 36 %), with and without surface oxygen plasma treatment. Also, previously reported data for a conventional HEMA-SCL (W{sub 10} = 38 %) hydrogel are reexamined and compared with those for SofLens{trademark} One Day and PureVision{trademark} hydrogels. Measured steady-state water fluxes are largest for SofLens{trademark} One Day, followed by PureVision{trademark} and HEMA. In some cases, the measured steady-state water fluxes increase with rising relative air humidity. This increase, due to an apparent mass-transfer resistance at the surface (trapping skinning), is associated with formation of a glassy skin at the air/membrane interface when the relative humidity is below 55-75%. Steady-state water-fluxes are interpreted through an extended Maxwell-Stefan diffusion model for a mixture of species starkly different in size. Thermodynamic nonideality is considered through Flory-Rehner polymer-solution theory. Shrinking/swelling is self-consistently modeled by conservation of the total polymer mass. Fitted Maxwell-Stefan diffusivities increase significantly with water concentration in the contact lens.

  5. Effects of phacoemulsification combined with intraocular lens implantation on ocular surface

    Directory of Open Access Journals (Sweden)

    Ming Li

    2013-10-01

    Full Text Available AIM: To explore the changes of ocular surface after phacoemulsification combined with intraocular lens implantation. METHODS: Totally 78 cases of 78 eyes with age-related cataract were collected from August 2011 to October 2012, and they underwent corneal incision phacoemulsification combined with intraocular lens implantation. The score of dry eye symptoms; tear breakup time(BUT; Schirmer Ⅰ test(SⅠtand corneal fluorescein staining were observed and recorded in 3 days before, 1 day, 1 week, 1 month, 3 and 6 months after surgery respectively. The results were analyzed statistically. RESULTS: All the subjects complained of dry eye within 1 week after surgery. Compared with 3 days before the surgery, the corneal fluorescein staining increased and the amount of tear secretion reduced statistically significant in 1 day, 1 week and 1 month(PPP>0.05, and lasted to 3 months later. CONCLUSION: Phacoemulsification combined with intraocular lens implantation has obvious effect on the ocular surface to some extent. Preventions and treatment should be taken clinically.

  6. Four-year Follow-up of the Changes in Anterior Segment After Phakic Collamer Lens Implantation.

    Science.gov (United States)

    Lu, Yuanyuan; Yang, Na; Li, Xuedong; Kong, Jun

    2017-06-01

    To assess the changes and relationship in central vaulting, flare intensity, and crystalline lens thickness during a follow-up period of 4 years after implantable collamer lens (ICL) implantation in eyes with high myopia. Retrospective observational study. Ninety-eight eyes of 50 patients were followed up with routine measurements of central vaulting, crystalline lens thickness, endothelial cell density, and aqueous flare postoperatively. Data were analyzed by repeated-measures analysis of variance. The relationship between the annual change in crystal lens thickness after surgery and age was evaluated by Pearson correlation coefficient and linear regression. There was a continuous reduction in central vaulting and endothelial cell density as well as an increase in crystalline lens thickness in ICL eyes from 1 month onward to 5 years postoperatively (P lens thickness (r = 0.617, P lens thickness are more prominent during the first year after ICL implantation, tending to be relatively stable afterwards. The anterior inflammation during the early postoperative period synchronizes with the sharp progression of crystalline lens changes within the first year. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Pseudophakodonesis and corneal endothelial contact: direct observations by high-speed cinematography.

    Science.gov (United States)

    Jacobs, P M; Cheng, H; Price, N C

    1983-01-01

    High-speed cinematography was used to observe the movement of Federov type I lens implants within the anterior chamber. Our measurements suggest that in most patients contact between the lens implant and corneal endothelium does not occur. Images PMID:6615750

  8. Clinical assessment of diclofenac sodium eye drops in toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Yan Luo

    2013-05-01

    Full Text Available AIM:To evaluate the application of diclofenac sodium eye drops in toric intraocular lens implantation. METHODS: From January 2011 to February 2012, 38 eyes of 37 patients, who underwent toric intraocular lens implantation in this hospital, were randomly divided into diclofenac sodium eye drops group(trial groupand control group. Patient's degree of cooperation during surgery and inflammation postoperation after 1 day, 3,7, days, 1 month and 3 months were evaluated. RESULTS: Patient's degree of cooperation during surgery in the trial group(1.53±0.62was significantly better than in the control group(2.40±0.88, P<0.05. Inflammation reaction was gentle in the trial group 1 day postoperatively. CONCLUSION: Diclofenac sodium eye drops used during toric intraocular lens implantation can obviously alleviate eye irritation, and increase the cooperation of patients.

  9. IOL Implants: Lens Replacement and Cataract Surgery (Intraocular Lenses)

    Science.gov (United States)

    ... Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On Pediatric Ophthalmology ... Are Cataracts? Pediatric Cataracts Cataract Diagnosis and Treatment Cataract Surgery IOL Implants: Lens Replacement After Cataracts ...

  10. [Current quality management situation and administration countermeasure study of enterprises marketing corneal contact lens].

    Science.gov (United States)

    Liu, Yungui; Yao, Ying; Shangguan, Shihao; Gu, Qun; Gao, Wuming; Chen, Yaoshui

    2014-05-01

    Study the current quality management situation of enterprises marketing corneal contact lens via systemic investigations and explore effective administration countermeasures in the future. The quality management indicators of sixty-two corneal contact lens marketing enterprises in Xuhui district of Shanghai were systematically investigated and enterprises of different operation models was compared and analyzed. Wholesale enterprises and retail chain enterprises are apparently better than independent enterprises almost in all facets. Facilitate market accession of corneal contact lens marketing enterprises, encourage the business model of retail chain, enhance supervision of corneal contact lens marketing enterprises, especially independent franchisors.

  11. In-vitro analysis of the microbicidal activity of 6 contact lens care solutions

    Directory of Open Access Journals (Sweden)

    Hildebrandt Claudia

    2012-10-01

    Full Text Available Abstract Background Contact lens-related infections are often associated with inadequate contact lens hygiene, and therefore, contact lens care products should be able to sufficiently minimise the amount of pathogens that are responsible for these infections. In 2001, the EN ISO 14729 was introduced to ensure adequate disinfection efficacy of contact lens care solutions, but this norm has recently been criticised. Methods In this study, six frequently used contact lens care solutions were retested according to the Stand Alone Test of the EN ISO 14729 (2001. The Stand Alone Test is a quantitative suspension test. In addition, the products were tested in a modified setting adding an organic load. The load was a mixture of human blood serum, lysozyme, and mucine, which resembles tear fluid. Results The criteria of the Stand Alone Test recommended in EN ISO 14729 were only met by Aosept Plus. This 3% hydrogen-peroxide-based contact lens care solution attained a reduction factor of > 5 log units for bacteria and > 4 for fungi in all cases. Two further contact lens care solutions, Blue Vision and Optifree Replenish, met the criteria of a reduction factor of > 3 log units for bacteria and > 1 log unit for fungi, but only in the presence of artificial tear fluid. The three remaining products did not exhibit adequate disinfecting efficacy, at least against one of the tested microorganisms. Conclusions Through the observation that the artificial tear fluid used in this study influences the disinfecting efficacy of contact lens care solutions, especially that of multi-purpose solutions, in a different way than does albumin, mucine, or even the organic load suggested in EN ISO 14729, it becomes obvious that the test conditions in the EN ISO 14729 should be revised in order to create more realistic conditions, e.g., by using a more realistic artificial tear fluid. Furthermore, we suggest adapting the EN ISO 14729 to the European test hierarchy for chemical

  12. Ocular discomfort responses after short periods of contact lens wear.

    Science.gov (United States)

    Papas, Eric; Tilia, Daniel; McNally, John; de la Jara, Percy Lazon

    2015-06-01

    To investigate if contact lens-related discomfort is a function of the time of day at which lenses are worn. This was a randomized, crossover, open-label clinical trial where subjective responses, with and without contact lenses, were assessed every 2 hours during five stages (A to E). Each stage began at the time when subjects would normally have inserted their contact lenses (T0). During stage A, no lenses were worn, whereas in stage B, lenses were worn continuously for 12 hours. In stages C to E, lenses were worn for only 4 hours. Contact lenses were inserted at T0 for stage C, but for stages D and E, lenses were not inserted until T0 + 4 and T0 + 8 hours, respectively. Mixed linear models were used for statistical analysis. In the absence of contact lenses, ocular comfort and dryness remained reasonably constant throughout the observation period. Ocular comfort and dryness decreased during 12 hours of continuous lens wear and became significantly worse from the 8-hour time onward compared with insertion (p 0.05) to the first 4 hours of continuous contact lens wear. Comparing the scores of each of these stages with the no-lens response at the corresponding time showed no significant differences for comfort (p > 0.23) or dryness (p > 0.37). Short periods of wear can be experienced at any time of day without significant change in ocular discomfort and dryness. This suggests that subjective responses at the end of the day are determined by the length of time lenses are in contact with the eye, rather than the time of day at which lenses are worn.

  13. Black diaphragm intraocular lens implantation and penetrating keratoplasty in aphakic eyes with traumatic aniridia

    Directory of Open Access Journals (Sweden)

    Xiao-Guang Dong

    2013-04-01

    Full Text Available AIM: To evaluate the long-term outcome of implantation of black diaphragm intraocular (BDI lens combined with penetrating keratoplasty (PKP for managing aphakic eyes with traumatic aniridia and corneal damage. METHODS: Six aphakic eyes of six patients with traumatic aniridia and corneal damage had BDI lens implantation at Qingdao Eye Hospital, Shandong Eye Institute from June 2008 to November 2011. Medical records of the patients were reviewed. Three patients received PKP and after 12-18months were implanted with BDI lens. The other three patients completed PKP and BDI lens implantation at the same time. The corrected visual acuity, intraocular pressure and number of corneal endothelial cells were monitored. RESULTS: The patients were followed up for an average of 24.3±12.1months (range 14-48 months. All BDI lenses were located well. The best corrected visual acuity got improved in 5 patients (0.1-1.0 and decreased in 1 patient from 0.4 to 0.2. Three patients had normal intraocular pressure (IOP after implantation. Two patients required antiglaucoma medications to control IOP within the normal range and 1 patient implanted Ahmed glaucoma valve to control IOP. The corneal grafts kept transparent in all eyes and the corneal endothelial counting >1 000/mm2, although two patients experienced acute graft rejection and loss more than 30% corneal endothelial cells. CONCLUSION: Implantation of BDI lens combined with PKP is an effective option for managing aphakic eyes with traumatic aniridia and corneal damage. Although the results in our study are encouraging, additional studies of the long-term safety and efficacy are required. A larger study population and longer follow-up may be beneficial.

  14. Effect of microwave treatment to acanthamoeba: a possibility of contact lens storage case sterilization?

    International Nuclear Information System (INIS)

    Hiti, K.; Faschinger, C.; Haller-Schober, E.M.; Walochnik, J.; Aspoeck, H.; Hiti, B.

    2003-01-01

    Microbially contaminated contact lens storage cases are considered to be a predisposing risk factor for Acanthamoeba keratitis. What kind of effect does microwave irradiation have on contact lens cases contaminated with Acanthamoeba cysts and trophozoites? Different types of contact lens cases were contaminated with trophozoites and cysts of three different Acanthamoeba species (A. hatchetti, A. castellanii, A. comandoni) and exposed to microwave irradiation for 3, 5 and 8 minutes respectively. One of the three test series was run with dehydrated cysts. After an irradiation period of 3 minutes under humid conditions cysts and trophozoites of all three strains were completely destroyed. Dehydrated cysts of A. hatchetti and A. castellanii were not killed by irradiation. There were no negative effects of irradiation on the contact lens cases themselves. Acanthamoeba cysts and trophozoites are effectively killed by microwave irradiation on condition that irradiation takes place in humid conditions. This can be easily achieved by filling the contact lens storage cases with tap water. We recommend microwave irradiation as a cheap and save method for the sterilization of contact lens cases in order to avoid a possible Acanthamoeba infection of the eye. (author)

  15. The use of contact lens telescopic systems in low vision rehabilitation.

    Science.gov (United States)

    Vincent, Stephen J

    2017-06-01

    Refracting telescopes are afocal compound optical systems consisting of two lenses that produce an apparent magnification of the retinal image. They are routinely used in visual rehabilitation in the form of monocular or binocular hand held low vision aids, and head or spectacle-mounted devices to improve distance visual acuity, and with slight modifications, to enhance acuity for near and intermediate tasks. Since the advent of ground glass haptic lenses in the 1930's, contact lenses have been employed as a useful refracting element of telescopic systems; primarily as a mobile ocular lens (the eyepiece), that moves with the eye. Telescopes which incorporate a contact lens eyepiece significantly improve the weight, comesis, and field of view compared to traditional spectacle-mounted telescopes, in addition to potential related psycho-social benefits. This review summarises the underlying optics and use of contact lenses to provide telescopic magnification from the era of Descartes, to Dallos, and the present day. The limitations and clinical challenges associated with such devices are discussed, along with the potential future use of reflecting telescopes incorporated within scleral lenses and tactile contact lens systems in low vision rehabilitation. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. The influence of end of day silicone hydrogel daily disposable contact lens fit on ocular comfort, physiology and lens wettability.

    Science.gov (United States)

    Wolffsohn, James; Hall, Lee; Mroczkowska, Stephanie; Hunt, Olivia A; Bilkhu, Paramdeep; Drew, Tom; Sheppard, Amy

    2015-10-01

    To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Thirty-nine subjects (22.1±3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Lens fit assessments were not different between brands (P>0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12h (P0.05). Movement-on-blink was unaffected by wear-time (F=0.403, P=0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r=-0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P>0.01). Among the lenses tested, objective lens fit changed between 8h and 12h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  17. Bacterial transmission from lens storage cases to contact lenses-Effects of lens care solutions and silver impregnation of cases.

    Science.gov (United States)

    Vermeltfoort, Pit B J; Hooymans, Johanna M M; Busscher, Henk J; van der Mei, Henny C

    2008-10-01

    The killing efficacies of multipurpose lens care solutions on planktonic and biofilm bacteria grown in polypropylene contact lens storage cases with and without silver impregnation and effects on bacterial transmission from storage cases to silicone hydrogel contact lenses were investigated. For transmission studies, biofilms of Staphylococcus aureus 835 or Pseudomonas aeruginosa no. 3 were grown on lens storage cases and incubated with a contact lens in different multipurpose lens care solutions (Opti-Free(R)Express(R), ReNu(R) MultiPlus(R), and SoloCare Aquatrade mark) or 0.9% NaCl. In addition, planktonic bacteria were directly suspended in multipurpose solutions and their killing efficacies were determined. The numbers of transmitted live and dead bacteria on the lenses were measured using a combination of plate counting and fluorescence microscopy. The highest killing efficacies were shown by Opti-Free(R) Express(R) for planktonic as well as for biofilm bacteria. Silver impregnation of lens cases in combination with the prescribed solution increased the killing efficacy for P. aeruginosa in biofilms, whereas effects for S. aureus were minor. Lowest numbers of live and dead bacteria were transmitted to a lens in Opti-Free(R) Express(R) multipurpose solution, with no significant differences between lens types and no effects of silver impregnation. (c) 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 2008. (c) 2008 Wiley Periodicals, Inc.

  18. Ocular surface and tear film status among contact lens wearers and non-wearers who use VDT at work: comparing three different lens types.

    Science.gov (United States)

    Tauste, Ana; Ronda, Elena; Baste, Valborg; Bråtveit, Magne; Moen, Bente E; Seguí Crespo, María-Del-Mar

    2018-04-01

    To analyze differences in the ocular surface appearance and tear film status of contact lens wearers and non-wearers in a group of visual display terminals (VDT) workers and additionally to assess differences between lens materials. Cross-sectional study of 236 office workers, of whom 92 were contact lens wearers. Workers provided information on their contact lenses (conventional hydrogel, silicone hydrogel or rigid gas permeable lenses) and exposure to VDT at work. Ocular surface and tear film status were determined by the presence of bulbar, limbal and lid redness, lid roughness and corneal staining type, and by Schirmer's and tear break-up time tests (TBUT). A generalized linear model was used to calculate the crude (cRR) and age- and sex-adjusted (aRR) relative risk to measure the association between ocular surface and tear film abnormalities and contact lens use and type. The aRR of ocular surface abnormalities was higher in contact lens wearers compared to non-wearers: bulbar redness (aRR 1.69; 95% CI 1.25-2.30), limbal redness (aRR 2.87; 1.88-4.37), lid redness (aRR 2.53; 1.35-4.73) and lid roughness (aRR 7.03; 1.31-37.82). VDT exposure > 4 h/day increased wearers' risk of limbal and lid redness. Conventional hydrogel wearers had the highest risk of ocular surface abnormalities, followed by silicone hydrogel wearers. Both contact and non-contact lens wearers had a high prevalence of altered TBUT (77.3 and 75.7% respectively) and Schirmer (51.8 and 41.3%). Regular contact lens use during VDT exposure at work increases risk of bulbar, limbal and lid redness, and lid roughness, especially in soft contact lens wearers. The high prevalence of altered TBUT and Schirmer's results in all participants suggests that VDT use greatly affects tear film characteristics.

  19. Acanthamoeba keratitis in a non-contact lens wearer with human immunodeficiency virus

    DEFF Research Database (Denmark)

    Hansen, Birgitte Rønde; Kronborg, Gitte

    2003-01-01

    Acanthamoeba keratitis is potentially blinding and often associated with contact lens wearing. A human immunodeficiency virus (HIV)-positive patient, a non-contact lens wearer, presented with keratitis. She experienced a protracted course of disease, characterized by exacerbations and remissions......, and was treated with various topical antibiotics and steroids. 13 months after symptom onset the eye was removed owing to serious scarring of cornea and unbearable pain. Microbiological and histopathological examination of the cornea showed Acanthamoeba. In non-contact lens wearers suffering from Acanthamoeba...... keratitis the diagnosis is delayed, pathognomonic features are often not seen and visual outcome is usually poor. There is no known relation between HIV infection and Acanthamoeba keratitis....

  20. Oral omega-6 essential fatty acid treatment in contact lens associated dry eye.

    Science.gov (United States)

    Kokke, Karolien H; Morris, Judith A; Lawrenson, John G

    2008-06-01

    Symptoms of dry eye are commonly reported in contact lens wearers and are a frequent cause of non-tolerance. The purpose of the present study is to evaluate the effects of oral treatment with particular omega-6 fatty acids in the form of evening primrose oil (EPO) on subjective symptoms, ocular surface signs and tear film characteristic in patients with contact lens associated dry eye. The study design was randomised, double-masked and placebo controlled. 76 female soft contact lens wearers were treated for 6 months with either EPO or placebo (olive oil). Subjects underwent three examinations (baseline, 3 and 6 months). At each examination subjects were given a questionnaire relating to lens comfort and dry eye symptoms and underwent a series of tests of tear film characteristics (tear meniscus height, break-up time), meibomian gland function (lipid layer thickness and quality) and ocular surface parameters (hyperaemia and staining). The EPO group showed a significant improvement in the specific symptom of 'dryness' at 3 and 6 months (porally administered omega-6 fatty acids in alleviating dry eye symptoms and improving overall lens comfort in patients suffering from contact lens associated dry eye.

  1. Clinical performance of Rose K2 soft contact lens for keratoconus

    Directory of Open Access Journals (Sweden)

    Ihsan Yilmaz

    2017-08-01

    Full Text Available AIM: To evaluate the comfort and visual performance of Rose K2 soft contact lenses in patients with keratoconus.METHODS: Fifty eyes of 50 participants were included in this cross-sectional study. Each participant received a full ophthalmologic examination involving refraction, uncorrected visual acuity(UCVA, best spectacle corrected visual acuity(BCVA, slit-lamp biomicroscopy-fundoscopy, break-up time(BUT, corneal topography, and contrast sensitivity. After contact lens was fitted best contact lens corrected visual acuity(BCLCVA, contrast sensitivity, and comfort rating via visual analogue scales(VASwere performed.RESULTS: The mean age was 26.2±6.0(range: 16 to 39y. The mean logMAR UCVA, BCVA, and BCLCVA with Rose K2 soft(in orderwere 0.61±0.37(range: 0.15-1.3, 0.42±0.32(range: 0-1.3, and 0.18±0.20(range: 0-1.3. There were significant increases in visual acuities with contact lenses(P P CONCLUSION: Rose K2 soft contact lens can improve visual acuity, contrast sensitivity with comfort in patients with keratoconus.

  2. Performance evaluation of delefilcon a water gradient daily disposable contact lenses in first-time contact lens wearers.

    Science.gov (United States)

    Marx, Sebastian; Lauenborg, Bo; Kern, Jami R

    2018-02-06

    To evaluate the tolerability of and subject and investigator satisfaction with delefilcon A (DAILIES TOTAL1 ® ) daily disposable contact lenses in first-time contact lens wearers. This European multicenter, open-label, single-arm, two-week trial enrolled first-time contact lens wearers and fitted them with delefilcon A contact lenses. Assessments were made at dispensing and at Weeks 1 and 2. Subject-reported outcomes included comfort, quality of vision, convenience, and intent to purchase, which were ranked by agreement responses. Investigator-reported outcomes included slit-lamp biomicroscopy findings and lens fit satisfaction. Ninety-two subjects were included in the per protocol dataset. Mean scores at Weeks 1 and 2 for subject-reported quality of vision and ocular comfort were significantly higher with delefilcon A contact lenses than with the subjects' habitual spectacles during the day, at the end of the day, and overall (all p ≤ 0.02). Ninety-one percent of subjects reported that their study lenses were more comfortable than expected, 98% agreed that they were convenient to use, and 92% were interested in purchasing the lenses (all p disposable contact lenses. Copyright © 2017. Published by Elsevier Ltd.

  3. Contact Lens Safety (A Minute of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    2016-08-18

    Contact lenses are a convenient alternative to glasses, but improper care and use can result in infections which can lead to eye damage. This podcast discusses contact lens safety.  Created: 8/18/2016 by MMWR.   Date Released: 8/18/2016.

  4. Clinical observation of Artisan iris-clip intraocular lens implantation at stage Ⅰ

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2014-09-01

    Full Text Available AIM: To observe the clinical efficacy of Artisan iris-clip intraocular lens(IOLimplantation on cataract with a wide range of lens dislocation.METHODS: Twenty-four hospital patients(28 eyesof cataract with lens subluxation by trauma(20 patients, 20 eyesand Marfan's syndrome(4 patients, 8 eyesduring May 2007 to December 2011 were selected. All of them underwent phacoemulsification or an anterior vitrectomy and Artisan iris-clip IOL implantation at stage Ⅰ. Postoperative visual acuity, corneal endothelial cell count, intraocular lens position and postoperative complications were observed. Follow-up time was 6mo.RESULTS:Compared with the preoperative, postoperative best corrected visual acuity improved to varying degrees, visual acuity of 0.1-0.5 was in 20 eyes, 0.5-1.0 in 8 eyes. After followed up 1-6mo, no artificial lens shift, iris inflammation, iris atrophy and corneal decompensation and other complications were observed.CONCLUSION: Cataract surgery with a wide range of lens dislocation is difficult, but as long as surgeons who have a wealth of clinical experience and superb skills, still can carry out phacoemulsification surgery or anterior vitrectomy and Artisan iris-clip IOL implantation and obtain a better outcome.

  5. External ocular surface and lens microbiota in contact lens wearers with corneal infiltrates during extended wear of hydrogel lenses.

    Science.gov (United States)

    Willcox, Mark; Sharma, Savitri; Naduvilath, Thomas J; Sankaridurg, Padmaja R; Gopinathan, Usha; Holden, Brien A

    2011-03-01

    To determine whether carriage of microbes on the contact lens or ocular surfaces during extended wear (EW) with soft hydroxyethyl methacrylate (HEMA)-based contact lenses predisposes the wearer to adverse events. Participants (non-contact lens wearers) were enrolled in a clinical study involving wear of HEMA-based hydrogel lenses on a six night EW basis with weekly replacement. Type and number of bacteria colonizing the lower lid margins, upper bulbar conjunctiva, and contact lenses during EW after one night, 1 week, 1 month, and thereafter every 3 months for 3.5 years were determined. The association of bacteria with adverse responses was compared between carriers (defined as having significant microbes cultured from two or more samples with 1 year) and noncarriers, and the strength of the association was estimated using multivariate logistic regression. Carriers of gram-positive bacteria on lenses (particularly coagulase negative staphylococci or Corynebacterium spp.) were approximately three and eight times more likely to develop contact lens-induced peripheral ulcers (CLPUs) and asymptomatic infiltrates (AIs), respectively. Staphylococcus aureus was most frequently isolated from lenses during CLPU. Carriers of gram-negative bacteria on lenses were five times more likely to develop contact lens-induced acute red eye (CLARE). Haemophilus influenzae was isolated most frequently from lenses during CLARE and AI events. Bacterial carriage on contact lenses during EW predisposes the wearer to the development of corneal inflammatory events including CLARE, CLPU, and AI.

  6. Rat silicone hydrogel contact lens model: effects of high- versus low-Dk lens wear.

    Science.gov (United States)

    Zhang, Yunfan; Gabriel, Manal M; Mowrey-McKee, Mary F; Barrett, Ronald P; McClellan, Sharon; Hazlett, Linda D

    2008-11-01

    This study used a rat contact lens (CL) model to test if high- versus low-Dk lens wear caused changes in (1) conjunctival Langerhans cell (LC) number or location; (2) Bcl-2 expression; and (3) infection risk. Female, Lewis rats wore a high- or low-Dk CL continuously for 2 weeks. Afterward, corneas were harvested and processed for ADPase activity to identify LCs, for immunostaining and for real time-polymerase chain reaction. Contact lens-wearing rats also were challenged with Pseudomonas aeruginosa by placing a bacterial-soaked CL on the eye followed by topical delivery of bacteria. After 48 hrs, slit lamp examination and real time-polymerase chain reaction were used to evaluate the corneal response. Conjunctival LC were significantly increased after low- versus high-Dk CL wear (PDk lens wearing group. Bcl-2 mRNA levels were significantly decreased in low- versus high-Dk CL wearing rats, while Bax, FasL, caspase 3, and caspase 9 levels were unchanged. Immunostaining for Bcl-2 showed fewer positively stained epithelial cells in the low- versus high-Dk lens wearing group. After bacterial challenge, 30% of low- versus none of the high-Dk CL wearing corneas became infected and showed increased mRNA levels for several proinflammatory cytokines/chemokines, inducible nitric oxide synthase and matrix metalloproteinase-9. Low- versus high-Dk or non-CL wear led to an increased number of conjunctival LC, decreased Bcl-2 levels, and increased the risk of bacterial infection.

  7. Phospholipids and their degrading enzyme in the tears of soft contact lens wearers.

    Science.gov (United States)

    Yamada, Masakazu; Mochizuki, Hiroshi; Kawashima, Motoko; Hata, Seiichiro

    2006-12-01

    Low tear phospholipids levels are associated with tear film instability in soft contact lens wearers. We assayed levels of phospholipids and their degrading enzyme secretory phospholipase A2 (sPLA2) both in tears and deposited on contact lenses composed of 2 hydrophilic materials after 1 day of routine use. Polymacon (Medalist; FDA group 1, low water/nonionic) and Etafilcon A (One Day Acuvue; group 4, high water/ionic) contact lenses were worn for 12 hours by 16 experienced contact lens wearers. Phospholipids in tear fluids and deposited on contact lenses were estimated by phosphorus determination with ammonium molybdate through enzymatic digestion. Double-antibody sandwich ELISA was used to determine group IIa sPLA2 concentrations, and sPLA2 activity was assayed using 1,2-diheptanoyl thio-phosphatidylcholine as substrate. Phospholipids concentrations in tears with Polymacon and Etafilcon A were 186 +/- 39 and 162 +/- 33 microg/mL, respectively. The latter concentration was significantly lower than that observed in the same subjects when not wearing contact lenses (P = 0.0023). In tears, both group IIa sPLA2 concentrations and enzymatic activity remained unchanged, regardless of lens wearing. However, Etafilcon A (0.57 +/- 0.09 microg/lens) showed more group IIa sPLA2 deposition than Polymacon (0.01 +/- 0.01 microg/lens; P < 0.001). Furthermore, group IIa sPLA2 deposited on Etafilcon A but not on Polymacon lenses retained its enzymatic activity. Significant differences of group IIa sPLA2 deposition were found in the 2 lenses tested. Such deposition might induce phospholipid hydrolysis in tears and thereby promote tear film instability in hydrophilic contact lens wearers.

  8. Immunoglobulin Concentration in Tears of Contact Lens Wearers

    Directory of Open Access Journals (Sweden)

    Rajendra P Maurya

    2014-01-01

    Conclusion: The relation of immunoglobulin concentration with increasing duration of wear and material of contact lens shows that tear immunoglobulin rise accrues due to mechanical stimulation, hence contact lenses should not be used for a long period and lenses of hard nature should be discouraged. The maintenance, cleaning and deproteinization of the lenses are of high importance to avoid immunostimulation.

  9. Surface modification of fluorosilicone acrylate RGP contact lens via low-temperature argon plasma

    International Nuclear Information System (INIS)

    Yin Shiheng; Wang Yingjun; Ren Li; Zhao Lianna; Kuang Tongchun; Chen Hao; Qu Jia

    2008-01-01

    A fluorosilicone acrylate rigid gas permeable (RGP) contact lens was modified via argon plasma to improve surface hydrophilicity and resistance to protein deposition. The influence of plasma treatment on surface chemical structure, hydrophilicity and morphology of RGP lens was investigated by X-ray photoelectron spectrometer (XPS), contact angle measurements and scanning electron microscope (SEM), respectively. The contact angle results showed that the hydrophilicity of the contact lens was improved after plasma treatment. XPS results indicated that the incorporation of oxygen-containing groups on surface and the transformation of silicone into hydrophilic silicate after plasma treatment are the main reasons for the surface hydrophilicity improvement. SEM results showed that argon plasma with higher power could lead to surface etching

  10. Corneal cell adhesion to contact lens hydrogel materials enhanced via tear film protein deposition.

    Directory of Open Access Journals (Sweden)

    Claire M Elkins

    Full Text Available Tear film protein deposition on contact lens hydrogels has been well characterized from the perspective of bacterial adhesion and viability. However, the effect of protein deposition on lens interactions with the corneal epithelium remains largely unexplored. The current study employs a live cell rheometer to quantify human corneal epithelial cell adhesion to soft contact lenses fouled with the tear film protein lysozyme. PureVision balafilcon A and AirOptix lotrafilcon B lenses were soaked for five days in either phosphate buffered saline (PBS, borate buffered saline (BBS, or Sensitive Eyes Plus Saline Solution (Sensitive Eyes, either pure or in the presence of lysozyme. Treated contact lenses were then contacted to a live monolayer of corneal epithelial cells for two hours, after which the contact lens was sheared laterally. The apparent cell monolayer relaxation modulus was then used to quantify the extent of cell adhesion to the contact lens surface. For both lens types, lysozyme increased corneal cell adhesion to the contact lens, with the apparent cell monolayer relaxation modulus increasing up to an order of magnitude in the presence of protein. The magnitude of this increase depended on the identity of the soaking solution: lenses soaked in borate-buffered solutions (BBS, Sensitive Eyes exhibited a much greater increase in cell attachment upon protein addition than those soaked in PBS. Significantly, all measurements were conducted while subjecting the cells to moderate surface pressures and shear rates, similar to those experienced by corneal cells in vivo.

  11. [Hyperopic Laser-in-situ-Keratomileusis after trifocal intraocular lens implantation : Aberration-free femto-Laser-in-situ-Keratomileusis treatment after implantation of a diffractive, multifocal, toric intraocular lens-case analysis].

    Science.gov (United States)

    Hemkeppler, E; Böhm, M; Kohnen, T

    2018-05-29

    A 52-year-old highly myopic female patient was implanted with a multifocal, diffractive, toric intraocular lens because of the wish to be independent of eyeglasses. Despite high-quality, extensive preoperative examinations, a hyperopic refractive error remained postoperatively, which led to the patient's dissatisfaction. This error was treated with Laser-in-situ-Keratomileusis (LASIK). After corneal LASIK treatment and implantation of a diffractive toric multifocal intraocular lens the patient showed a good postoperative visual result without optical phenomena.

  12. Which soft contact lens power is better for piggyback fitting in keratoconus?

    Science.gov (United States)

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose Manuel

    2013-02-01

    To evaluate the impact of differente soft contact lens power in the anterior corneal curvature and regularity in subjects with keratoconus. Nineteen subjects (30 eyes) with keratoconus were included in the study. Six corneal topographies were taken with Pentacam Eye System over the naked eye and successively with soft lens (Senofilcon A) powers of -3.00, -1.50, 0.00, +1.50 and +3.00 D. Corneal measurements of mean central keratometry (MCK), maximum tangential curvature (TK), maximum front elevation (MFE) and eccentricity (Ecc) at 6 and 8 mm diameters as well as anterior corneal surface high order aberrations (i.e. total RMS, spherical- and coma-like and secondary astigmatism) were evaluated. Negative- and plano-powered soft lenses flattened (ppowered lenses did not induce any significant changes (p>0.05 in all cases) in MCK in comparison to the naked eye. The TK power decreased with negative lenses (psoft lens power in comparison to the naked eye (p>0.05 in all cases). Corneal eccentricity increased at 8 mm diameter for all lens powers (p0.05). Statistically differences were found in coma-like and secondary astigmatism (both ppowered soft contact lenses provide a flatter anterior surface in comparison to positive-powered lenses in subjects with keratoconus and thus they might be more suitable for piggyback contact lens fitting. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  13. A Class I UV-Blocking (senofilcon A) Soft Contact Lens Prevents UVA-induced Yellow Fluorescence and NADH loss in the Rabbit Lens Nucleus in vivo

    Science.gov (United States)

    Giblin, Frank J.; Lin, Li-Ren; Simpanya, Mukoma F.; Leverenz, Victor R.; Fick, Catherine E.

    2012-01-01

    It is known that fluorescence, much of it caused by UVA light excitation, increases in the aging human lens, resulting in loss of sharp vision. This study used an in vivo animal model to investigate UVA-excited fluorescence in the rabbit lens, which contains a high level of the UVA chromophore NADH, existing both free and bound to λ-crystallin. Also, the ability of a Class I (senofilcon A) soft contact lens to protect against UVA-induced effects on the rabbit lens was tested. Rabbit eyes were irradiated with UVA light in vivo (100 mW/cm2 on the cornea) for 1 hour using monochromatic 365 nm light. Irradiation was conducted in the presence of either a senofilcon A contact lens, a minimally UV-absorbing lotrafilcon A contact lens, or no contact lens at all. Eyes irradiated without a contact lens showed blue 365 nm-excited fluorescence initially, but this changed to intense yellow fluorescence after 1 hour. Isolated, previously irradiated lenses exhibited yellow fluorescence originating from the lens nucleus when viewed under 365 nm light, but showed normal blue fluorescence arising from the cortex. Previously irradiated lenses also exhibited a faint yellow color when observed under visible light. The senofilcon A contact lens protected completely against the UVA-induced effects on fluorescence and lens yellowing, whereas the lotrafilcon A lens showed no protection. The UVA-exposure also produced a 53% loss of total NADH (free plus bound) in the lens nucleus, with only a 13% drop in the anterior cortex. NADH loss in the nucleus was completely prevented with use of a senofilcon A contact lens, but no significant protection was observed with a lotrafilcon A lens. Overall, the senofilcon A lens provided an average of 67% protection against UVA-induced loss of four pyridine nucleotides in four different regions of the lens. HPLC analysis with fluorescence detection indicated a nearly six-fold increase in 365 nm-excited yellow fluorescence arising from lens nuclear

  14. Experimental Contact Lens to Prevent Glaucoma-Induced Blindness

    Science.gov (United States)

    ... An Experimental Contact Lens to Prevent Glaucoma-Induced Blindness By Sharon Reynolds Posted January 23, 2014 An ... group of conditions that can result in irreversible blindness. This vision loss can be reduced if glaucoma ...

  15. Contact lens wear by Royal Air Force aircrew in World War II.

    Science.gov (United States)

    Pearson, Richard M

    2014-04-01

    To provide an overview of the use of contact lenses by RAF aircrew in World War II by identifying some of the fitters and wearers and appraising the clinical results that they achieved. A wide-ranging literature search was undertaken that encompassed peer-reviewed journals, non-refereed publications, books, official publications, newspapers and archived documents. Thirty-one aircrew are known to have worn sealed scleral lenses in order to meet the required visual standards. Of these, only two were considered to be completely unsuccessful, one of whom was unilaterally aphakic. One additional case of undisclosed contact lens wear was found and the identity of this officer was established. Brief biographies of a few pilots establish the context of their contact lens wear. Overall, the results of scleral lens wear were variable reflecting those achieved by civilian patients of the period. While three men complained of discomfort due to heat and glare, one pilot experienced no photophobia when flying above white clouds in brilliant sunshine and another found no difficulty caused by altitude or tropical climate. Wearing time ranged from about 2h to 16, or more, hours. In about a third of the cases, wearing time was limited due to the onset of a form of contact lens induced-epithelial oedema known as Sattler's veil and effective solutions to this problem were not implemented until after the war. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Bacterial and fungal biofilm formation on contact lenses and their susceptibility to lens care solutions

    Directory of Open Access Journals (Sweden)

    Siddharth Kackar

    2017-01-01

    Full Text Available Background: Microbial biofilm formation on contact lenses and lens storage cases may be a risk factor for contact lens-associated corneal infections. Various types of contact lens care solutions are used to reduce microbial growths on lenses. Objectives: The present study aimed at comparing the growths of biofilms on the different contact lenses and lens cases. The study also aimed at determining the effect of lens care solutions and bacteriophage on these biofilms. Materials and Methods: One type of hard lens and two types of soft lenses were used for the study. The organisms used were Staphylococcus aureus ATCC 25923, Pseudomonas aeruginosa ATCC 27853, Candida albicans ATCC 60193 and Escherichia coli ATCC 25922. Biofilm production was performed by modified O'Toole and Kolter method and effect of lens cleaning solutions and a crude coliphage on biofilms was also studied. Results were visualised using scanning electron microscopy and quantitated by colony counting method and spectrophotometric measurement of optical density (OD. Statistical analysis was done by SPSS 11.5, Kruskal–Wallis test and Chi-square test. Results: Soft lens cleaning solutions had a significant inhibitory effect (P = 0.020 on biofilm formation on soft lenses and also lens cases (P < 0.001. Soft lens cleaning solution 2 was more efficient than solution 1. However, no such inhibitory effect was observed with regard to hard lens cleaning solution, but for a significant reduction in the OD values (P < 0.001. There was no significant inhibitory effect by bacteriophages. Conclusion: This study showed the importance of selecting the appropriate lens cleaning solution to prevent biofilm production on contact lenses.

  17. Resistance of Acanthamoeba cysts to disinfection in multiple contact lens solutions.

    Science.gov (United States)

    Johnston, Stephanie P; Sriram, Rama; Qvarnstrom, Yvonne; Roy, Sharon; Verani, Jennifer; Yoder, Jonathan; Lorick, Suchita; Roberts, Jacquelin; Beach, Michael J; Visvesvara, Govinda

    2009-07-01

    Acanthamoebae are free-living amoebae found in the environment, including soil, freshwater, brackish water, seawater, hot tubs, and Jacuzzis. Acanthamoeba species can cause keratitis, a painful vision-threatening infection of the cornea, and fatal granulomatous encephalitis in humans. More than 20 species of Acanthamoeba belonging to morphological groups I, II, and III distributed in 15 genotypes have been described. Among these, Acanthamoeba castellanii, A. polyphaga, and A. hatchetti are frequently identified as causing Acanthamoeba keratitis (AK). Improper contact lens care and contact with nonsterile water while wearing contact lenses are known risk factors for AK. During a recent multistate outbreak, AK was found to be associated with the use of Advanced Medical Optics Complete MoisturePlus multipurpose contact lens solution, which was hypothesized to have had insufficient anti-Acanthamoeba activity. As part of the investigation of that outbreak, we compared the efficacies of 11 different contact lens solutions against cysts of A. castellanii, A. polyphaga, and A. hatchetti (the isolates of all species were genotype T4), which were isolated in 2007 from specimens obtained during the outbreak investigation. The data, generated with A. castellanii, A. polyphaga, and A. hatchetti cysts, suggest that the two contact lens solutions containing hydrogen peroxide were the only solutions that showed any disinfection ability, with 0% and 66% growth, respectively, being detected with A. castellanii and 0% and 33% growth, respectively, being detected with A. polyphaga. There was no statistically significant difference in disinfection efficacy between the 11 solutions for A. hatchetti.

  18. [Ocular and visual alterations in computer workers contact lens wearers: scoping review].

    Science.gov (United States)

    Tauste Francés, Ana; Ronda-Pérez, Elena; Seguí Crespo, María del Mar

    2014-01-01

    The high number of computer workers wearing contact lenses raises the question whether the sum of these two risk factors for eye health may cause a worsening of Computer Vision Syndrome. The aim of this review is to synthesize the knowledge about ocular and visual alterations related with computer use in contact lens wearers. International review of scientific papers (2003-2013) in Spanish and English, using Scoping Review method, in Medline through PubMed and in Scopus. The initial search provided 114 references, after applying inclusion/exclusion criteria six of them were included. All of them reveal that symptoms when using computer are more prevalent in contact lens wearers, with values of symptoms presentation prevalence ranging from 95.0% to 16.9% in wearers and from 57.5% to 9.9% in non-wearers, and four times more likely to develop dry eye [OR: 4.07 (95% CI: 3.52 to 4.71)]. Computer workers suffer more ocular and visual disturbances if they also are contact lens users, but studies are few and non conclusive. Likewise, further research regarding contact lens type and their conditions of use, both in symptoms and tear quality and ocular surface are needed. Silicone hydrogel lenses are associated with more comfort.

  19. The impact of cellular debris on Pseudomonas aeruginosa adherence to silicone hydrogel contact lenses and contact lens storage cases.

    Science.gov (United States)

    Burnham, Geoffrey W; Cavanagh, H Dwight; Robertson, Danielle M

    2012-01-01

    To evaluate neutrophil-enhanced Pseudomonas aeruginosa (PA) biofilm formation on silicone hydrogel contact lenses and to determine the effect of epithelial biodebris on PA adherence in contact lens storage cases. A fully invasive PA corneal isolate stably conjugated to green fluorescent protein was used. Unworn lotrafilcon A contact lenses were incubated at various ratios of PA to polymorphonuclear neutrophil (PMN) for 24 hours at 37°C. Lens-associated PA was evaluated using laser scanning confocal microscopy and nonviable PA were visualized using propidium iodide. Viable bacteria were enumerated by colony-forming unit (CFU) analysis. For acute epithelial cell studies, PA viability was determined after coincubation with freeze-thaw epithelial cell lysates in 96-well polystyrene plates. Levels of residual cellular debris and bacterial viability were further assessed in used contact lens storage cases. Laser scanning confocal microscopy demonstrated that cotreatment with PMA-stimulated neutrophils increased PA adherence over 24 hours to lens surfaces with a striking alteration of PA architecture. Propidium iodide staining showed that the adherent bacteria consisted of a mixture of viable and nonviable PA; a PMN-associated increase in viable PA was confirmed by CFU (PA:PMN 0.1:1, P = 0.025; PA:PMN 1:1, P = 0.005). Acute epithelial cell debris studies revealed a significant increase in viable PA in 96-well plates in the presence of epithelial freeze-thaw lysates (PA:debris 1:1, P = 0.002; PA:debris 100:1, P = 0.002). Crystal violet staining of used lens storage cases revealed residual cellular debris at all time points, which was independent of microbial contamination; all lens cases used for periods of 9 months or more were uniformly associated with high levels of viable microorganisms. These results demonstrate that prolonged corneal inflammation with the presence of PMNs when confronted with simultaneous PA challenge in extended contact lens wear has the potential

  20. Clinical observation of capsular tension ring implantation in congenital lens subluxation treating by phacoemulsification

    OpenAIRE

    Liang-Nan Sun; Bai-Jun Li; Yuan-Fei Zhu; Xin-Hua Liu

    2017-01-01

    AIM: To evaluate the clinical results of capsular tension ring(CTR)implantation in phacoemulsification for eyes with congenital lens subluxation. METHODS: This study comprised 18 patients(31 eyes)with congenital ectopia lentis. All patients received phacoemulsification with CTR and intraocular lens(IOL)implantation. Visual acuity before and after surgery were examined. IOL decentration were measured with Image-Pro Plus image processing software. The complications were also recorded preoperati...

  1. Bacterial adhesion forces to Ag-impregnated contact lens cases and transmission to contact lenses.

    Science.gov (United States)

    Qu, Wenwen; Busscher, Henk J; van der Mei, Henny C; Hooymans, Johanna M M

    2013-03-01

    To measure adhesion forces of Pseudomonas aeruginosa, Staphylococcus aureus, and Serratia marcescens to a rigid contact lens (CL), standard polypropylene, and Ag-impregnated lens cases using atomic force microscopy and determine bacterial transmission from lens case to CL. Adhesion forces of bacterial strains to Ag-impregnated and polypropylene lens cases and a rigid CL were measured using atomic force microscopy. Adhesion forces were used to calculate Weibull distributions, from which transmission probabilities from lens case to CL were derived. Transmission probabilities were compared with actual transmission of viable bacteria from a lens case to the CL in 0.9% NaCl and in an antimicrobial lens care solution. Bacterial transmission probabilities from polypropylene lens cases based on force analysis coincided well for all strains with actual transmission in 0.9% NaCl. Bacterial adhesion forces on Ag-impregnated lens cases were much smaller than that on polypropylene and CLs, yielding a high probability of transmission. Comparison with actual bacterial transmission indicated bacterial killing due to Ag ions during colony-forming unit transmission from an Ag-impregnated lens case, especially for P. aeruginosa. Transmission of viable bacteria from Ag-impregnated lens cases could be further decreased by use of an antimicrobial lens care solution instead of 0.9% NaCl. Bacterial transmission probabilities are higher from Ag-impregnated lens cases than from polypropylene lens cases because of small adhesion forces, but this is compensated for by enhanced bacterial killing due to Ag impregnation, especially when in combination with an antimicrobial lens care solution. This calls for a balanced combination of antimicrobial lens care solutions and surface properties of a lens case and CL.

  2. RISK FACTORS FOR CONTACT LENS COMPLICATIONS

    Directory of Open Access Journals (Sweden)

    Mirna Štabuc Šilih

    2016-04-01

    Full Text Available Contact lenses are freely available without professional examination and fitting, as well as without adequate introduction and instructions on handling, disinfection and storage. Contact lenses may have physiological, metabolic and anatomic effect on the eyes, which is manifested both on the eyelids, lacrimal film, conjunctiva and in all layers of the cornea - the epithelium, stroma and the endothelium. We can see these complications too often at our everyday work. The purpose of this paper is to draw attention to the potential complications due to inappropriate use of contact lenses.Contact lenses are otherwise a safe and effective method of correcting visual acuity; they are also useful for therapeutic purposes. Complications related to contact lenses wear could be largely avoided with an appropriate professional approach and the compliance of contact lens wearers. It is important to discuss with patients their medical history, their desires and expectations, their working and living environment; followed by professional examination of patients and appropriate fitting of contact lenses. Patients should receive detailed oral and written instructions and be subscribed to regular checks. But unfortunately, all this is not enough, if patients do not comply every day with given instructions.

  3. Hand hygiene prior to contact lens handling is problematical.

    Science.gov (United States)

    McMonnies, Charles W

    2012-04-01

    To establish guidelines for contact lens wearers' hand hygiene practices which achieve a balance between minimising risk of infection and reasonable expectations on the ability of patients to follow them. Evidence has been obtained from publications via PubMed, Advanced Medline Search, Cochrane Reviews, Google Scholar and using the key words hand hygiene, washing and contact lens. Guidelines for effective hand washing and the bother involved vary according to the level of hygiene required. High levels of non-compliance with hand hygiene practices, even among healthcare workers, gives an indication of how important the level of bother involved when following guidelines can be in contributing to non-compliance. Better patient education to improve hand washing techniques as well as patient attitudes toward hand hygiene are needed to reduce high non-compliance levels. Better hand hygiene techniques and higher frequency of their application give the prospect of reduced risk of infection and of any discomfort that arises from increased lens and ocular bioburden. In order that adoption rates might be maximised, the guidelines which have been distilled from this review attempt to strike a balance between technique redundancy and the associated higher levels of hygiene achieved and the possibility that the perception of too much bother involved could reduce participation rates. The guidelines have been expanded by the inclusion of suggested explanatory information in the expectation that helping patients to understand why the recommendations are made will have the effect of increasing their adoption. Copyright © 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  4. Resistance of Pseudomonas aeruginosa isolates to hydrogel contact lens disinfection correlates with cytotoxic activity.

    Science.gov (United States)

    Lakkis, C; Fleiszig, S M

    2001-04-01

    One of the most common pathogens in infection of hydrogel contact lens wearers is Pseudomonas aeruginosa, which can gain access to the eye via contamination of the lens, lens case, and lens care solutions. Only one strain per species is used in current regulatory testing for the marketing of chemical contact lens disinfectants. The aim of this study was to determine whether P. aeruginosa strains vary in their susceptibility to hydrogel contact lens disinfectants. A method for rapidly screening bacterial susceptibility to contact lens disinfectants was developed, based on measurement of the MIC. The susceptibility of 35 P. aeruginosa isolates to two chemical disinfectants was found to vary among strains. MICs ranged from 6.25 to 100% for both disinfectants at 37 degrees C, and a number of strains were not inhibited by a 100% disinfectant concentration in the lens case environment at room temperature (22 degrees C). Resistance to disinfection appeared to be an inherent rather than acquired trait, since some resistant strains had been isolated prior to the introduction of the disinfectants and some susceptible P. aeruginosa strains could not be made more resistant by repeated disinfectant exposure. A number of P. aeruginosa strains which were comparatively more resistant to short-term disinfectant exposure also demonstrated the ability to grow to levels above the initial inoculum in one chemical disinfectant after long-term (24 to 48 h) disinfectant exposure. Resistance was correlated with acute cytotoxic activity toward corneal epithelial cells and with exsA, which encodes a protein that regulates cytotoxicity via a complex type III secretion system. These results suggest that chemical disinfection solutions may select for contamination with cytotoxic strains. Further investigation of the mechanisms and factors responsible for resistance may also lead to strategies for reducing adverse responses to contact lens wear.

  5. Efficacy on chopping with lens loop-pad in the small incision extracapsular cataract surgery with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Xiao-Ning Peng

    2014-04-01

    Full Text Available AIM: To study the clinical effects of chopping with lens loop-pad in the small incision extracapsular cataract surgery with intraocular lens implantation.METHODS:A total of 75 cases(80 eyes, in which loop-pad and chop knife were performed to chop nucleus before implanting intraocular lens. Visual acuity, postoperative astigmatism degree, intraoperative and postoperative complications were observed. The post-operative follow-up periods ranged from 3 to 12mo.RESULTS: The visual acuity was 0.3-0.5 in 37 eyes and 0.6 or better in 21 eyes at 1d, while was respectively in 43 eyes and in 26 eyes at 1mo. Compared with preoperative astigmatism(0.85±0.29D, there were significant difference at postoperative 1wk(1.75±0.55D(PP>0.05. Intraoperative posterior capsule rupture occurred in 4 eyes, which implantation was successful in 1 eye and 3 eyes was managed viaciliary sulcus. Two eyes had dermatoglyphic pattern edema in corneal endothelium which recovered after about 3d. Two eyes had local patchy opacities which recovered in 2wk. Two eyes had transient high intraocular pressure.CONCLUSION: The surgery is efficient, low cost, easy process and less complications, it is worth to be popularized.

  6. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant

    Directory of Open Access Journals (Sweden)

    Clara Ye

    2018-06-01

    Full Text Available Purpose: We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL (Visian ICL™, Staar Inc., Monrovia, CA implant that resulted in advanced visual field loss. Observations: A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Conclusions and importance: Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss. Keywords: Phakic intraocular lens, Intraocular collamer lens, Pigment dispersion, Glaucoma

  7. Oral omega-3 fatty acid treatment for dry eye in contact lens wearers.

    Science.gov (United States)

    Bhargava, Rahul; Kumar, Prachi

    2015-04-01

    The aim of this study was to evaluate the effect of dietary omega-3 fatty acid (O3FA) supplementation on dry eye symptoms, tear film tests, and conjunctival impression cytology in patients with contact lens wear-associated dry eye. In this randomized, double-blind, multicentric trial, contact lens wearers (n = 496) were randomized to receive either O3FAs or placebo capsules (corn oil) twice daily for 6 months. Subjects underwent examinations at baseline, 3 months, and 6 months. At each visit, a questionnaire of dry eye symptoms and lens wear comfort was administered. Subjects further underwent measurement of tear film break-up time (TBUT) and a Schirmer test. Conjunctival impression cytology was performed by the transfer method. Improvement in symptoms and lens wear comfort were primary outcome measures. Changes from baseline in TBUT, Schirmer, and Nelson grade at 6 months were secondary outcome measures. The mean improvement in symptom score in the O3FA group was 4.7 ± 2 (2.0) as compared with 0.5 ± 2 (0.9) in the placebo group (P dry eye symptoms, improving lens wear comfort, and cytological changes in contact lens wearers.

  8. A contact-lens-shaped IC chip technology

    International Nuclear Information System (INIS)

    Liu, Ching-Yu; Yang, Frank; Teng, Chih-Chiao; Fan, Long-Sheng

    2014-01-01

    We report on novel contact-lens-shaped silicon integrated circuit chip technology for applications such as forming a conforming retinal prosthesis. This is achieved by means of patterning thin films of high residual stress on top of a shaped thin silicon substrate. Several strategies are employed to achieve curvatures of various amounts. Firstly, high residual stress on a thin film makes a thin chip deform into a designed three-dimensional shape. Also, a series of patterned stress films and ‘petal-shaped’ chips were fabricated and analyzed. Large curvatures can also be formed and maintained by the packaging process of bonding the chips to constraining elements such as thin-film polymer ring structures. As a demonstration, a complementary metal oxide semiconductor transistor (CMOS) image-sensing retina chip is made into a contact-lens shape conforming to a human eyeball 12.5 mm in radius. This non-planar and flexible chip technology provides a desirable device surface interface to soft tissues or non-planar bio surfaces and opens up many other possibilities for biomedical applications. (paper)

  9. Intraocular pressure measurement over soft contact lens by rebound tonometer: a comparative study.

    Science.gov (United States)

    Nacaroglu, Senay Asik; Un, Emine Seker; Ersoz, Mehmet Giray; Tasci, Yelda

    2015-01-01

    To evaluate the intraocular pressure (IOP) measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry (GAT). Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens (RTCL, RT respectively) and by GAT, as well as their central corneal thickness (CCT) by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis. Mean IOP values measured by RTCL, RT and GAT were 15.68±3.7, 14.50±3.4 and 14.16±2.8 (Pcontact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population.

  10. A Class I UV-blocking (senofilcon A) soft contact lens prevents UVA-induced yellow fluorescence and NADH loss in the rabbit lens nucleus in vivo.

    Science.gov (United States)

    Giblin, Frank J; Lin, Li-Ren; Simpanya, Mukoma F; Leverenz, Victor R; Fick, Catherine E

    2012-09-01

    It is known that fluorescence, much of it caused by UVA light excitation, increases in the aging human lens, resulting in loss of sharp vision. This study used an in vivo animal model to investigate UVA-excited fluorescence in the rabbit lens, which contains a high level of the UVA chromophore NADH, existing both free and bound to λ-crystallin. Also, the ability of a Class I (senofilcon A) soft contact lens to protect against UVA-induced effects on the rabbit lens was tested. Rabbit eyes were irradiated with UVA light in vivo (100 mW/cm(2) on the cornea) for 1 h using monochromatic 365 nm light. Irradiation was conducted in the presence of either a senofilcon A contact lens, a minimally UV-absorbing lotrafilcon A contact lens, or no contact lens at all. Eyes irradiated without a contact lens showed blue 365 nm-excited fluorescence initially, but this changed to intense yellow fluorescence after 1 h. Isolated, previously irradiated lenses exhibited yellow fluorescence originating from the lens nucleus when viewed under 365 nm light, but showed normal blue fluorescence arising from the cortex. Previously irradiated lenses also exhibited a faint yellow color when observed under visible light. The senofilcon A contact lens protected completely against the UVA-induced effects on fluorescence and lens yellowing, whereas the lotrafilcon A lens showed no protection. The UVA-exposure also produced a 53% loss of total NADH (free plus bound) in the lens nucleus, with only a 13% drop in the anterior cortex. NADH loss in the nucleus was completely prevented with use of a senofilcon A contact lens, but no significant protection was observed with a lotrafilcon A lens. Overall, the senofilcon A lens provided an average of 67% protection against UVA-induced loss of four pyridine nucleotides in four different regions of the lens. HPLC analysis with fluorescence detection indicated a nearly six-fold increase in 365 nm-excited yellow fluorescence arising from lens nuclear

  11. Ge-semiconductor detectors with a p-implanted n+-contact

    International Nuclear Information System (INIS)

    Protic, D.; Riepe, G.

    1979-01-01

    P-implanted large-surface-detectors with improved properties can be produced by implantation of the n + -contact with relatively low dose and high energy. After an annealing process a nearly perfect lattice structure is obtained. By a subsequent p-implantation step with high dose and low energy, the surface restisivity can be reduced. The p + -contacts are obtained by B-implantation. (DG) [de

  12. A novel phosphorylcholine-coated contact lens for extended wear use.

    Science.gov (United States)

    Court, J L; Redman, R P; Wang, J H; Leppard, S W; Obyrne, V J; Small, S A; Lewis, A L; Jones, S A; Stratford, P W

    2001-12-01

    The preparation and characterisation of a new phosphorylcholine (PC)-coated silicone hydrogel contact lens for use in extended wear is described. The Michael-type addition of amines to acrylates forms the basis of the synthesis of a novel silicone-based macromer with hydrophilic functionality. It is demonstrated that this macromer can be combined with other silicone-based monomers, hydrophilic monomers and crosslinker to produce a contact lenses formulation. Examples of lenses with water contents of 33% and 46% are illustrated and their properties compared to other commercially available lenses. Materials with comparatively low modulus (2-4MPa) with excellent elongation to break (>200%) can be obtained using this technology. In addition to the mechanical aspects. both the oxygen and solute permeabilities of the material can be controlled by the hydrophilic: hydrophobic monomer balance in the formulation. to obtain materials with attributes suitable for extended wear use. The PC coating is achieved by means of an in-mould coating (IMC) technique that produces a uniform and stable surface as determined by staining and XPS. The coating imparts both improved lens wettability (advancing contact angle of approximately 50 with virtually no hysteresis) and lower protein adsorption relative to the uncoated lens.

  13. Contact mechanics of reverse engineered distal humeral hemiarthroplasty implants.

    Science.gov (United States)

    Willing, Ryan; King, Graham J W; Johnson, James A

    2015-11-26

    Erosion of articular cartilage is a concern following distal humeral hemiarthroplasty, because native cartilage surfaces are placed in contact with stiff metallic implant components, which causes decreases in contact area and increases in contact stresses. Recently, reverse engineered implants have been proposed which are intended to promote more natural contact mechanics by reproducing the native bone or cartilage shape. In this study, finite element modeling is used in order to calculate changes in cartilage contact areas and stresses following distal humeral hemiarthroplasty with commercially available and reverse engineered implant designs. At the ulna, decreases in contact area were -34±3% (p=0.002), -27±1% (pengineered and cartilage reverse engineered designs, respectively. Peak contact stresses increased by 461±57% (p=0.008), 387±127% (p=0.229) and 165±16% (p=0.003). At the radius, decreases in contact area were -21±3% (p=0.013), -13±2% (p0.999), 241±32% (p=0.010) and 61±10% (p=0.021). Between the three different implant designs, the cartilage reverse engineered design yielded the largest contact areas and lowest contact stresses, but was still unable to reproduce the contact mechanics of the native joint. These findings align with a growing body of evidence indicating that although reverse engineered hemiarthroplasty implants can provide small improvements in contact mechanics when compared with commercially available designs, further optimization of shape and material properties is required in order reproduce native joint contact mechanics. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. A Case of Non-Contact Lens related Acanthamoeba keratitis in Malaysia

    Directory of Open Access Journals (Sweden)

    Mohamed Kamel, A. G.

    2005-01-01

    Full Text Available Acanthamoeba is a ubiquitous free-living amoeba and is responsible for an uncommon yet increasingly diagnosed keratitis in humans. Acanthamoeba keratitis is perhaps the most challenging ocular infection to manage successfully and it can result in permanently impaired vision or blindness. Although contact lens use is the principal risk factor, about 10% of cases occur following trauma and exposure to contaminated soil or water. Cases of Acanthamoeba keratitis involving contact lens wearers have previously been reported in Malaysia but this is the first time, a non-contact lens relatedAcanthamoeba keratitis is reported. The case involved a 28 year old Indonesian male construction worker who had a trauma of the right eye. While working his eye was struck by some sand and dust particles and he quickly washed his eye with water from an open tank at the construction site. He then experienced pain, redness, glaring and blurring of vision of the right eye. The diagnosis was missed at the initial presentation but subsequent culture of the corneal scraping demonstrated Acanthamoeba as the aetiological agent. The history, clinical findings, diagnosis and treatment of non-contact lens related Acanthamoeba keratitis are briefly discussed in this communication. We hope to create awareness especially among the medical and paramedical staff about the existence of this infection in the country and fully support the consideration of Acanthamoeba keratitis as part of the differential diagnosis of most cases of presumed microbial keratitis.

  15. A portable non-contact displacement sensor and its application of lens centration error measurement

    Science.gov (United States)

    Yu, Zong-Ru; Peng, Wei-Jei; Wang, Jung-Hsing; Chen, Po-Jui; Chen, Hua-Lin; Lin, Yi-Hao; Chen, Chun-Cheng; Hsu, Wei-Yao; Chen, Fong-Zhi

    2018-02-01

    We present a portable non-contact displacement sensor (NCDS) based on astigmatic method for micron displacement measurement. The NCDS are composed of a collimated laser, a polarized beam splitter, a 1/4 wave plate, an aspheric objective lens, an astigmatic lens and a four-quadrant photodiode. A visible laser source is adopted for easier alignment and usage. The dimension of the sensor is limited to 115 mm x 36 mm x 56 mm, and a control box is used for dealing with signal and power control between the sensor and computer. The NCDS performs micron-accuracy with +/-30 μm working range and the working distance is constrained in few millimeters. We also demonstrate the application of the NCDS for lens centration error measurement, which is similar to the total indicator runout (TIR) or edge thickness difference (ETD) of a lens measurement using contact dial indicator. This application has advantage for measuring lens made in soft materials that would be starched by using contact dial indicator.

  16. Fluctuation in visual acuity during soft toric contact lens wear.

    Science.gov (United States)

    Chamberlain, Paul; Morgan, Philip B; Moody, Kurt J; Maldonado-Codina, Carole

    2011-04-01

    To quantify changes in visual acuity (VA) with soft toric contact lenses as a result of lens movement and/or rotational instability caused by versional eye movements. A novel chart for vision assessment at near (40 cm) for soft toric contact lenses (VANT chart),consisting of a central, color-coded logMAR panel and eight peripheral letter targets set on a white background measuring 60 × 40 cm was constructed. In the developmental phase of the work, 10 subjects (20 eyes) wore 2 toric lenses in random order, and the impact of rapid and delayed eye versions in 8 directions of gaze on VANT acuity was investigated. In phase 2, 35 subjects (68 eyes) wore 4 toric lenses in random order, and a streamlined clinical protocol using the VANT chart was implemented. Standard assessments of toric lens fit and distance VA were also performed. Testing in the first phase showed no difference for change in VA for rapid vs. delayed version movements, (p = 0.17) but acuity reduction was greater for diagonal compared with horizontal/vertical versions (p = 0.06). As such, testing in phase 2 proceeded using rapid, diagonal versions only. In this second phase, there were differences for low-contrast distance VA measures between lens types (p = 0.02) and for both VANT baseline acuity (p = 0.03) and postversion acuity (p = 0.04), but no differences were found between lenses for magnitude of vision loss (p = 0.91), which was about one line. No relationship was established between the magnitude of vision loss and measured rotational stability (p = 0.75). This work has demonstrated that conventional approaches to measuring VA do not fully replicate the "real world" experience of soft toric lens wearers. The VANT chart has shown that VA is reduced immediately after versional eye movements and suggests that more dynamic methods of assessing visual performance should be considered for soft toric contact lens wearers, especially given the apparent inability of lens stability measurements to predict

  17. On- and off-eye spherical aberration of soft contact lenses and consequent changes of effective lens power.

    Science.gov (United States)

    Dietze, Holger H; Cox, Michael J

    2003-02-01

    Soft contact lenses produce a significant level of spherical aberration affecting their power on-eye. A simple model assuming that a thin soft contact lens aligns to the cornea predicts that these effects are similar on-eye and off-eye. The wavefront aberration for 17 eyes and 33 soft contact lenses on-eye was measured with a Shack-Hartmann wavefront sensor. The Zernike coefficients describing the on-eye spherical aberration of the soft contact lens were compared with off-eye ray-tracing results. Paraxial and effective lens power changes were determined. The model predicts the on-eye spherical aberration of soft contact lenses closely. The resulting power change for a +/- 7.00 D spherical soft contact lens is +/- 0.5 D for a 6-mm pupil diameter and +/- 0.1 D for a 3-mm pupil diameter. Power change is negligible for soft contact lenses corrected for off-eye spherical aberration. For thin soft contact lenses, the level of spherical aberration and the consequent power change is similar on-eye and off-eye. Soft contact lenses corrected for spherical aberration in air will be expected to be aberration-free on-eye and produce only negligibly small power changes. For soft contact lenses without aberration correction, for higher levels of ametropia and large pupils, the soft contact lens power should be determined with trial lenses with their power and p value similar to the prescribed lens. The benefit of soft contact lenses corrected for spherical aberration depends on the level of ocular spherical aberration.

  18. Oral omega-6 essential fatty acid treatment in contact lens associated dry eye.

    OpenAIRE

    Kokke, K. H.; Morris, J. A.; Lawrenson, J.

    2008-01-01

    Symptoms of dry eye are commonly reported in contact lens wearers and are a frequent cause of non-tolerance. The purpose of the present study is to evaluate the effects of oral treatment with particular omega-6 fatty acids in the form of evening primrose oil (EPO) on subjective symptoms, ocular surface signs and tear film characteristic in patients with contact lens associated dry eye.

  19. A class I (Senofilcon A) soft contact lens prevents UVB-induced ocular effects, including cataract, in the rabbit in vivo.

    Science.gov (United States)

    Giblin, Frank J; Lin, Li-Ren; Leverenz, Victor R; Dang, Loan

    2011-06-01

    UVB radiation from sunlight is known to be a risk factor for human cataract. The purpose in this study was to investigate the ability of a class I UV-blocking soft contact lens to protect against UVB-induced effects on the ocular tissues of the rabbit in vivo. Eyes of rabbits were exposed to UVB light for 30 minutes (270-360 nm, peak at 310 nm, 1.7 mW/cm(2) on the cornea). Eyes were irradiated in the presence of either a UV-blocking senofilcon A contact lens, a minimally UV-blocking lotrafilcon A contact lens, or no contact lens at all. Effects on the cornea and lens were evaluated at various times after exposure. Eyes irradiated with no contact lens protection showed corneal epithelial cell loss plus lens epithelial cell swelling, vacuole formation, and DNA single-strand breaks, as well as lens anterior subcapsular opacification. The senofilcon A lens protected nearly completely against the UVB-induced effects, whereas the lotrafilcon A lens showed no protection. The results indicate that use of a senofilcon A contact lens is beneficial in protecting ocular tissues of the rabbit against the harmful effects of UVB light, including photokeratitis and cataract.

  20. [Comparative analysis of visual function and the quality of life index with eyeglasses or a progressive contact lens].

    Science.gov (United States)

    Sant'Anna, Neusa Vidal; Schor, Paulo; Lipener, César; Uras, Ricardo

    2006-01-01

    To compare the visual function and the answers to a questionnaire of quality of life of patients wearing a progressive contact lens or eyeglasses. The Focus Progressive contact lens had been fitted in 35 patients with far visual acuity with progressive-addition eyeglasses equal to zero (log MAR) and near J1 (Jaeger). The far and near visual acuities and the measurement of contrast sensitivity were compared when the patients were wearing the eyeglasses or the contact lens and the patients' results of the scores of the quality of life questionnaire (NEI VFQ-25) were analyzed statistically considering the type of ametropy and the age. The far and near visual acuities and the contrast sensitivity measurement were worse with the contact lens than with eyeglasses. The answers to the questionnaire did not differ when were comparing the same patients wearing eyeglasses or contact lens, no matter the type of ametropy. The myopic and the hyperopic subgroups had worse answers to the quality of life questionnaire when corrected with the contact lens than with eyeglasses, both with age equal to or less than their median. The visual function was worse with the contact lens. The type of ametropy did not influence the answers to the quality of life questionnaire considering the optical correction, but age did.

  1. Publication analysis of the contact lens field: what are the current topics of interest?

    Science.gov (United States)

    Cardona, Genís; Sanz, Joan P

    2015-01-01

    To determine the main current research interests of scientists working in the contact lens field. All articles published in the 2011 issues of all journals included in the Journal Citation Reports subject category Ophthalmology were inspected to expose those papers related to the contact lens field. Information regarding source journal was obtained and authorship details were recorded to determine the top most prolific authors, institutions and countries. A comprehensive list of key words was compiled to generate a two-dimensional term map in which the frequency of occurrence of a particular term is defined by label size and the distance between two terms is an indication of the relatedness of these terms, based on their co-occurrences within groups of key words. Clusters of related terms were also identified. Visual examination of all articles uncovered a total of 156 papers, published in 28 different journals. Contact Lens & Anterior Eye, Eye & Contact Lens and Optometry and Vision Science had 27 articles each. The most prolific authors and institutions revealed the predominance of countries with long research tradition in the contact lens field. Ten different word clusters or areas of interest were identified, including both traditional, yet unresolved issues (e.g., comfort or dry eye), and the latest research efforts (e.g., myopia control). These findings, which revealed contact lenses to be a fertile area of research, may be of relevance to new researchers as well as to those interested in exploring the latest research trends in this scientific discipline. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  2. [Lens exchange for subluxation of posterior chamber lenses implanted in the capsular bag or in the ciliary sulcus].

    Science.gov (United States)

    Stürmer, J

    2013-04-01

    There are an increasing number of patients with decreased vision due to dislocated posterior chamber lenses, with pseudoexfoliation being the main risk factor. Various techniques for refixation of the subluxated posterior chamber IOL have been described. Experience with our technique of IOL-explantation, anterior vitrectomy and implantation of an Artisan anterior chamber lens are presented. In a retrospective study design all lens exchanges with implantation of an Artisan anterior chamber lens performed between 2003 and 2012 are analyzed. The study included 65 eyes of 61 patients (age 79.6 ± 9.2 years: 43-98). The majority of eyes (46/65; 70.8%) had Sundown Syndrome (late in-the-bag intraocular lens dislocation), in 19 eyes the posterior chamber lens was implanted primary or secondary into the ciliary sulcus. In the 46 eyes with Sundown Syndrome cataract surgery with implantation of a posterior chamber lens in the capsular bag was performed 7.4 ± 3.7 (1-22) years before subluxation within the bag. Pseudoexfoliation was the main risk factor in 42/46 (91.2%) of these eyes. A capsular tension ring (CTR) was implanted during cataract surgery in 34/46 (73.9%) eyes. The 34 IOLs with a CTR luxated significantly earlier (p IOLs without a CTR (6.6 ± 3.6 years; median 5.8 vs. 9.4 ± 3.1 years; median 9.2). The average visual gain was 0.2 logMAR in the group of luxated capsular bag lenses and 0.12 logMAR in the group of luxated sulcus lenses. Postoperative IOP decompensation was seen in 17/65 (26.2%) eyes (requiring IOP-lowering surgery in 8 eyes), 7 eyes developed corneal decompensation, 5 eyes had central retinal vein occlusion and one eye developed postoperative endophthalmitis. Lens exchange with implantation of an Artisan anterior chamber lens has become a routine procedure to improve vision in patients with subluxated IOLs. Postoperative IOP decompensation and vascular problems are the major complications. Georg Thieme Verlag KG Stuttgart · New York.

  3. 21 CFR 886.5925 - Soft (hydrophilic) contact lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Soft (hydrophilic) contact lens. 886.5925 Section 886.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... against the cornea and adjacent limbal and scleral areas of the eye to correct vision conditions or act as...

  4. Polymicrobial Infection of the Cornea Due to Contact Lens Wear

    Directory of Open Access Journals (Sweden)

    Selçuk Sızmaz

    2016-04-01

    Full Text Available A 38-year-old male presented with pain and redness in his left eye. He had a history of wearing contact lenses. His ophthalmic examination revealed a large corneal ulcer with surrounding infiltrate. Cultures were isolated from the contact lenses, lens solutions, storage cases, and conjunctivae of both eyes and also corneal scrapings of the left eye. Fortified vancomycin and amikacin drops were started hourly. Culture results of conjunctivae of each eye and left cornea were positive for Pseudomonas aeruginosa; cultures from the contact lenses, lens solution and storage case of both eyes revealed Pseudomonas aeruginosa and Alcaligenes xylosoxidans. Polymerase chain reaction of the corneal scraping was positive for Acanthameoba. The topical antibiotics were changed with ones that both bacteria were sensitive to and anti-amoebic therapy was added. The patient had two recurrences following initial presentation despite intensive therapy. Keratitis occurred due to multiple pathogens; the relapsing course despite adequate therapy is potentially associated with this polymicrobial etiology.

  5. Visual outcomes after lensectomy and iris claw artisan intraocular lens implantation in patients with Marfan syndrome.

    Science.gov (United States)

    Rabie, Hossein Mohammad; Malekifar, Parviz; Javadi, Mohammad Ali; Roshandel, Danial; Esfandiari, Hamed

    2017-08-01

    To review our experience with crystalline lens extraction and iris claw Artisan IOL implantation in patients with lens subluxation secondary to Marfan syndrome. A retrospective analysis of 12 eyes of 9 patients with lens subluxation due to Marfan syndrome who underwent crystalline lens removal and Artisan IOL (Ophtec, Groningen, Netherlands) implantation. A questionnaire of pre- and post-operative data, including demographics, pre- and postoperative comorbidities and complications was completed. Patients were evaluated for visual outcome and occurrence of complications. Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), and spherical equivalents (SE) were compared before and after lens extraction and IOL insertion. The mean age of the participants was 30.03 ± 15.02 years, and mean post-operative follow-up time was 44.5 ± 16.4 months. Mean BCVA also showed a significant improvement from 0.5 ± 0.3 at the baseline to 0.2 ± 0.2 post-operatively (P = 0.006). SE changed significantly from -11.38 ± 1.99 preoperatively to -0.45 ± 1.65 post-operatively (P = 0.003). All eyes had the IOL implanted at desired position. Post-operative complications were retinal detachment in one case and IOL dislocation in another patient. No other complication such as ocular hypertension, angle abnormalities, clinical cystoids macular edema, and corneal decompensation was observed during the follow-up period. Artisan IOL implantation after lens extraction appears to be an attractive alternative for optical correction in cases of Marfan syndrome with ectopia lentis. It confers a significant improvement in visual acuity with reasonable risk profile.

  6. Micro sized implantable ball lens-based fiber optic probe design

    Science.gov (United States)

    Cha, Jaepyeong; Kang, Jin U.

    2014-02-01

    A micro sized implantable ball lens-based fiber optic probe design is described for continuous monitoring of brain activity in freely behaving mice. A prototype uses a 500-micron ball lens and a highly flexible 350-micron-diameter fiber bundle, which are enclosed by a 21G stainless steel sheath. Several types and thickness of brain tissue, consisting of fluorescent probes such as GFP, GCaMP3 calcium indicator, are used to evaluate the performance of the imaging probe. Measured working distance is approximately 400-μm, but is long enough to detect neural activities from cortical and cerebellar tissues of mice brain.

  7. Clinical Presentation and Microbial Analyses of Contact Lens Keratitis; an Epidemiologic Study

    Directory of Open Access Journals (Sweden)

    Seyed Ahmad Rasoulinejad

    2014-09-01

    Full Text Available Introduction: Microbial keratitis is an infective process of the cornea with a potentially and serious visual impairments. Contact lenses are a major cause of microbial keratitis in the developed countries especially among young people. Therefore, the purpose of the present study was to evaluate the frequency and microbiological characteristic of CLK in patients referred to the emergency department (ED of teaching hospitals, Babol, Iran. Methods: This is a cross-sectional study of all patients with contact lens induced corneal ulcers admitted to the teaching hospitals of Babol, Iran, from 2011- 2013. An ophthalmologist examined patients with the slit-lamp and clinical features of them were noted (including pain, redness, foreign body sensation, chemosis, epiphora, blurred vision, discomfort, photophobia, discharge, ocular redness and swelling. All suspected infectious corneal ulcers were scraped for microbial culture and two slides were prepared. Data were analyzed using SPSS software, version 18.0. Results: A total of 14 patients (17 eyes were recruited into the study (100% female. The patients’ age ranged from 16-37 years old (mean age 21.58±7.23 years. The most prevalent observed clinical signs were pain and redness. Three samples reported as sterile. The most common isolated causative organism was pseudomonas aeroginosa (78.6%, Staphylococcus aureus 14.3%, and enterobacter 7.1%, respectively. Treatment outcome was excellent in 23.5%, good in 47.1%, and poor in 29.4% of cases. Conclusion: Improper lens wear and care as well as the lack of awareness about the importance of aftercare visits have been identified as potential risk factors for the corneal ulcer among contact lens wearers. Training and increasing the awareness of adequate lens care and disinfection practices, consulting with an ophthalmologist, and frequent replacement of contact lens storage cases would greatly help reducing the risk of microbial keratitis.

  8. Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

    Science.gov (United States)

    Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed

    2014-01-01

    Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability.

  9. Inefficacy of marketed contact lens disinfection solutions against keratitis-causing Acanthamoeba castellanii belonging to the T4 genotype.

    Science.gov (United States)

    Lakhundi, Sahreena; Khan, Naveed Ahmed; Siddiqui, Ruqaiyyah

    2014-06-01

    The aim of this study was to assess the anti-amoebic effects of marketed contact lens disinfecting solutions. Using amoebistatic, amoebicidal, and cysticidal assays, nine different contact lens solutions were tested including: ReNu MultiPlus, DuraPlus, Ultimate Plus, OptiFree Replenish, OptiFree Express, Kontex Clean, Kontex Normal, Kontex Multisol extra+, Kontex Soak. In vitro growth inhibition (amoebistatic) assays were performed by incubating Acanthamoeba castellanii with aforementioned contact lens disinfection solutions as per manufacturer's instructions in the growth medium for up to 48h at 30°C. To determine amoebicidal and cysticidal effects, amoebae were incubated with contact lens solutions in phosphate buffered saline for 24h and viability was determined by haemocytometer counting as well as re-inoculating them in the growth medium. For controls, solutions were tested against bacterial corneal pathogen, Pseudomonas aeruginosa, as well as amoebae were incubated with the solvent alone. Of the nine contact lens solutions tested, none of them showed potent amoebicidal effects. Only DuraPlus and OptiFree Replenish exhibited trophozoite lysis of 85.3% and 73.7% respectively. In contrast, all contact lens disinfection solutions except Kontex Clean, Kontex Normal, Kontex Multisol extra+, tested showed amoebistatic effects. Importantly, none of the contact lens disinfection solutions exhibited cysticidal effects using qualitative assays, i.e., cysts treated with aforementioned solutions re-emerged as viable amoebae upon inoculation in the growth medium. However, more than 3-log reduction was observed when ReNu MultiPlus, DuraPlus and OptiFree Express were tested against P. aeruginosa which is in accordance with the ISO Stand-Alone Primary acceptance criteria. These findings are of great concern for contact lens users. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Visual performance after the implantation of a new trifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Vryghem JC

    2013-10-01

    Full Text Available Jérôme C Vryghem,1,2 Steven Heireman1,21Brussels Eye Doctors, Brussels, Belgium; 2Clinique Saint-Jean, Brussels, BelgiumPurpose: To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens.Methods: A new trifocal diffractive intraocular lens was designed combining two superimposed diffractive profiles: one with +1.75 diopters (D addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that were operated on by one surgeon are included in this study. The uncorrected and best distance-corrected monocular and binocular, near, intermediate, and distance visual acuities, contrast sensitivity, and defocus curves were measured 6 months postoperatively. In addition to the standard clinical follow-up, a questionnaire evaluating individual satisfaction and quality of life was submitted to the patients.Results: The mean age of patients at the time of surgery was 70 ± 10 years. The mean uncorrected and corrected monocular distance visual acuity (VA were LogMAR 0.06 ± 0.10 and LogMAR 0.00 ± 0.08, respectively. The outcomes for the binocular uncorrected distance visual acuity were almost the same (LogMAR −0.04 ± 0.09. LogMAR −010 ± 0.15 and 0.02 ± 0.06 were measured for the binocular uncorrected intermediate and near VA, respectively. The distance-corrected visual acuity was maintained in mesopic conditions. The contrast sensitivity was similar to that obtained after implantation of a bifocal intraocular lens and did not decrease in mesopic conditions. The binocular defocus curve confirms good VA even in the intermediate distance range, with a moderate decrease of less than LogMAR 0.2 at −1.5 D, with respect to the best distance VA at 0 D defocus. Patient satisfaction was high. No discrepancy between the objective and subjective outcomes was evidenced.Conclusion: The introduction of a third focus in diffractive multifocal

  11. Nonadhesive, silica nanoparticles-based brush-coated contact lens casesCompromising between ease of cleaning and microbial transmission to contact lenses

    NARCIS (Netherlands)

    Qu, Wenwen; Hooymans, Johanna M. M.; Qiu, Jun; de-Bont, Nik; Gelling, Onko-Jan; van der Mei, Henny C.; Busscher, Henk J.

    Surface properties of lens cases are determinant for their cleanability and for microbial transmission from lens cases to contact lenses (CLs). PEG-polymer-brush-coatings are known to decrease microbial adhesion more than other surface-coatings. Here, we applied a robust, silica nanoparticles-based

  12. 21 CFR 886.1385 - Polymethylmethacrylate (PMMA) diagnostic contact lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Polymethylmethacrylate (PMMA) diagnostic contact lens. 886.1385 Section 886.1385 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... directly on the globe or cornea of the eye for diagnosis or therapy of intraocular abnormalities. (b...

  13. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. [Seoul National University Hospital (Korea, Republic of)

    2015-06-15

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  14. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    International Nuclear Information System (INIS)

    Park, J.

    2015-01-01

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  15. 21 CFR 886.5916 - Rigid gas permeable contact lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid gas permeable contact lens. 886.5916 Section 886.5916 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... against the cornea of the eye to correct vision conditions. The device is made of various materials, such...

  16. Contact lens wearers' experiences while trekking in the Khumbu region/Nepal: a cross-sectional survey.

    Science.gov (United States)

    Bauer, Irmgard L

    2015-01-01

    Safe contact lens wear depends on a hygiene regime and lens-appropriate wear patterns which may be compromised during travel in remote and wilderness areas. The purpose of this study was to describe the experience of contact lens wearers while trekking at high-altitude in Nepal. For this descriptive study, trekkers with contact lenses were recruited in Lukla and invited to complete an online-questionnaire on trip preparation, contact lens use, care and experiences, and possible changes for future travel. Quantitative data were analysed using SurveyMonkey; content analysis applied to qualitative responses. The majority of the 158 participants (124; 78.48%) reported no problems with their lenses (daily disposables, soft lenses, extended-wear lenses, hard/rigid lenses) during their stay although dry air, dust, wind, cold temperatures, and difficult hygiene maintenance were challenging. Freezing lenses and freezing solutions were additional challenges. Thirty-four (21.52%) experienced a variety of problems. Improvements were requested from manufacturers. Lodges should provide better access to clean water, mirrors and lighting. Almost 60% of participants had not sought any pre-travel health advice. Remote and wilderness areas provide a challenge for appropriate contact lens wear and care. The decision between the potential risk of infection due to touching lenses (daily disposables, soft/hard lenses) and the potential risk of corneal erosion (extended-wear lenses) needs to be made in pre-travel consultations. Travel health professionals and travel agencies should remind CL-wearing trekkers to carefully assess their wear and care routine to accommodate potentially challenging conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Spontaneous Rotation of a Toric Implantable Collamer Lens

    Directory of Open Access Journals (Sweden)

    Alejandro Navas

    2010-11-01

    Full Text Available We present a case of toric implantable collamer lens (TICL spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA was 20/800 and 20/1200, respectively, with –7.75 –4.25 × 0° and –8.25 –5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/100 with a refraction of +2.50 –4.50 × 165°. We observed the toric marks with a 30° rotation from the original position and decided to reposition the TICL, obtaining a final UCVA of 20/25, which remained stable at 6 months’ follow-up. TICL can present a considerable rotation that compromises visual acuity. The relocation of TICL is a safe and effective procedure to recover visual acuity due to significant spontaneous TICL rotation.

  18. Characterization of Soft Contact Lens Edge Fitting during Daily Wear Using Ultrahigh-Resolution Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Lele Cui

    2018-01-01

    Full Text Available Purpose. To determine conjunctival overlap over the edge of soft contact lens and to visualize the peripheral postlens tear film (PoLTF underneath soft contact lenses using ultrahigh-resolution optical coherence tomography (UHR-OCT. Methods. Twenty participants (4 males and 16 females, 23.0 ± 3.7 years were fitted with two different types of soft contact lenses randomly. The limbus with lens was imaged with the UHR-OCT at the horizontal meridian every two hours up to 6 hours during lens wear. The conjunctival overlap was ranked as the percentage of the edge covered by the conjunctiva. The frequency of occurrence for visualized peripheral PoLTF was determined. Results. The average conjunctival overlaps at insertion were 49% and 73% for galyfilcon A and balafilcon A lenses and increased significantly to 84% and 90% by 6 hours of lens wear (P<0.001. Lenses with rounded edges had more conjunctival overlap than the lenses with angled edges (P=0.014. There were significant decreases for PoLTF on the conjunctiva (P=0.014 and peripheral cornea (P=0.004 over the study period compared to insertion. The percentage of subjects with PoLTF on the conjunctiva (32.5% and peripheral cornea (36% were greater in subjects wearing balafilcon A lenses (P=0.017. Conclusions. Increased conjunctival overlap over the lens edges and reduced PoLTF underneath the peripheral region of soft contact lenses were shown during lens daily wear. The lens edge configuration may play a role in conjunctival response and peripheral PoLTF.

  19. Effect of corneal cross-linking on contact lens tolerance in keratoconus.

    Science.gov (United States)

    Ünlü, Metin; Yüksel, Erdem; Bilgihan, Kamil

    2017-07-01

    The aim was to investigate changes in corneal sensation and rigid gas-permeable (RGP) contact lens tolerance after corneal cross-linking (CXL) on patients with keratoconus. Thirty eyes of 30 patients, who were RGP lens intolerant, were treated with CXL. The main outcome measures were corneal sensation evaluation by Cochet-Bonnet esthesiometry, sub-basal nerve fibre assessment by corneal in vivo confocal microscopy and RGP contact lens tolerance evaluation with the Likert scale and wearing time. All eyes were evaluated preoperatively and post-operatively at one, three and six months after CXL procedure. The mean age was 25.3 ± 6.2 years. Preoperatively, the maximum keratometry (Kmax) in study eyes was 56.89 ± 4.60 D. Six months after CXL, it reduced to 56.03 ± 4.85 D (p = 0.01). Preoperative mean corneal sensation was 0.44 ± 0.05 g/mm 2 , (range: 0.40 to 0.55); it was significantly decreased at the first month and increased to preoperative values after six months. The sub-basal nerve plexus could not be visualised in 90 per cent of the patients by confocal microscopy at one month post-operatively. Gradual restoration of corneal innervation with almost similar preoperative levels at post-operative month six was noted. There were significant differences in Likert scores between preoperative and third and sixth months after CXL. Likert scale scores correlated significantly with corneal sensitivity. It can be concluded that increased RGP contact lens tolerance after CXL may be associated with the potential role of decreased corneal sensitivity and corneal flattening after CXL. © 2016 Optometry Australia.

  20. Contact Lens-Induced Discomfort and Inflammatory Mediator Changes in Tears.

    Science.gov (United States)

    Masoudi, Simin; Zhao, Zhenjun; Stapleton, Fiona; Willcox, Mark

    2017-01-01

    Studies indicate that contact lens (CL) discontinuation mostly occurs because of dryness and discomfort symptoms. This study aimed to investigate relationships between changes in the concentration of tear inflammatory mediators with subjective comfort ratings with CL wear and no contact lens wear between morning and evening. Forty-five subjects collected tears twice daily in the morning and in the evening with or without lenses. Comfort was rated subjectively on a scale from 1 to 100 (where 100 was extremely comfortable) just before each tear collection. Tear samples were assayed for complement components (C3 and C3a), leukotriene B4 (LTB4), secretory phospholipase A2 (sPLA2), secretory immunoglobulin A (sIgA), and bradykinin using commercially available immuno-based assay kits. Comfort ratings showed a statistically significant decline from morning to evening both with CL (89.0±10.1 AM vs. 76.7±15.2 PM; P0.05). Leukotriene B4 levels were slightly higher in CL (CL 43.4±12.6 pg/ml vs. No CL 39.4±13.4 pg/mL; P=0.034), whereas the concentration of LTB4, C3, C3a, and sIgA dropped by the end of the day in the presence or absence of lens wear (Ptear levels were not correlated with comfort ratings in any of the conditions. Leukotriene B4 had a higher concentration in the evening, and when measured as a ratio to sIgA, there was a trend for increased concentration of this mediator during CL wear. Although specific mediators showed changes from morning to evening with and without lens wear, most of these were not correlated with subjective comfort ratings in lens wear. The only mediator that showed an increase in concentration during the day and during lens wear was LTB4, and further studies on this mediator are warranted.

  1. Castor oil and mineral oil nanoemulsion: development and compatibility with a soft contact lens.

    Science.gov (United States)

    Katzer, Tatiele; Chaves, Paula; Bernardi, Andressa; Pohlmann, Adriana R; Guterres, Silvia S; Beck, Ruy C R

    2014-03-01

    The non-invasive ophthalmic therapy has a drawback: low residence time in the eye socket. Nanoparticles and contact lenses have been studied as promising ocular drug delivery systems. To develop a nanoemulsion and evaluate its compatibility with a soft contact lens as a potential strategy for ocular delivery. The formulations were developed by spontaneous emulsification and fully characterized. Two drops of nanoemulsion were instilled on the surface of a commercial contact lens and its transparency was measured using a UV-Vis spectrophotometer. Before and after the instillation of the drops, the morphology (scanning electron microscopy - SEM) and ion permeability of the lenses were analyzed. The formulations had a mean particle size of 234 nm, polydispersity below 0.16, zeta potential of -8.56 ± 3.49 mV, slightly acid pH, viscosity ≈1.2 mPa s(-1) and spherical-shaped particles. Nanoemulsion was non-irritant (hen's egg test-chorioallantoic membrane), which was confirmed by the cytotoxicity studies in the SIRC cell cultures. After instillation, SEM analysis showed nanodroplets inside and on the surface of the lenses, although their transparency remained near 100%. No significant differences were found between lens ion permeability coefficients before and after instillation. Formulations presented appropriate physicochemical characteristics and suitability for ocular application. The contact lens remained transparent and ion-permeable after association with the formulation.

  2. Clinical observation of capsular tension ring implantation in congenital lens subluxation treating by phacoemulsification

    Directory of Open Access Journals (Sweden)

    Liang-Nan Sun

    2017-07-01

    Full Text Available AIM: To evaluate the clinical results of capsular tension ring(CTRimplantation in phacoemulsification for eyes with congenital lens subluxation. METHODS: This study comprised 18 patients(31 eyeswith congenital ectopia lentis. All patients received phacoemulsification with CTR and intraocular lens(IOLimplantation. Visual acuity before and after surgery were examined. IOL decentration were measured with Image-Pro Plus image processing software. The complications were also recorded preoperatively and postoperatively. RESULTS: Uncorrected vision of all eyes increased after surgery, and all cases had different degree of IOL decentration after surgery. Two eyes received CTR scleral fixation 3mo after surgery because the IOL decentration aggravated during the follow-up period. CONCLUSION: Phacoemulsification with CTR and IOL implantation is effective and safe for congenital lens subluxation. The implantation of CTR increase the stability of the capsular bag, improve the safety of surgery, and maintain the right position of IOL. CTR scleral fixation is a effective supplement for progressive cases.

  3. Contact lens-related polymicrobial keratitis from Pantoea agglomerans and Escherichia vulneris

    Directory of Open Access Journals (Sweden)

    Vincent D. Venincasa

    2016-04-01

    Conclusions: This is the first report of P. agglomerans and E. vulneris keratitis in association with contact lens wear. Both strains of P. agglomerans and E. vulneris were pansensitive to all tested antibiotics.

  4. An instrumented implant for in vivo measurement of contact forces and contact moments in the shoulder joint.

    Science.gov (United States)

    Westerhoff, P; Graichen, F; Bender, A; Rohlmann, A; Bergmann, G

    2009-03-01

    To improve implant design, fixation and preclinical testing, implant manufacturers depend on realistic data of loads acting on the shoulder joint. Furthermore, these data can help to optimize physiotherapeutic treatment and to advise patients in their everyday living conditions. Calculated shoulder joint loads vary extremely among different authors [Anglin C, Wyss UP, Pichora DR. Glenohumeral contact forces. Proc Inst Mech Eng [H] 2000;214:637-44]. Additionally the moments acting in the joint caused by friction or incongruent articular surfaces, for example, are not implemented in most models. An instrumented shoulder joint implant was developed to measure the contact forces and the contact moments acting in the glenohumeral joint. This article provides a detailed description of the implant, containing a nine-channel telemetry unit, six load sensors and an inductive power supply, all hermetically sealed inside the implant. The instrumented implant is based on a clinically proven BIOMET Biomodular shoulder replacement and was calibrated before implantation by using complex mathematical calculation routines in order to achieve an average measuring precision of approximately 2%.

  5. In Vitro Effect of Lysozyme on Albumin Deposition to Hydrogel Contact Lens Materials.

    Science.gov (United States)

    Babaei Omali, Negar; Subbaraman, Lakshman N; Heynen, Miriam; Fadli, Zohra; Coles-Brennan, Chantal; Jones, Lyndon W

    2017-11-01

    Albumin deposition on contact lenses could be detrimental to contact lens (CL) wear because this may increase the risk of bacterial binding and reduce comfort. Lysozyme deposition on selected lens materials would reduce albumin deposition on lenses. This study aims to determine if lysozyme deposition on CLs could act as a barrier against subsequent albumin adsorption, using an in vitro model. Six hydrogel CL materials (etafilcon A, polymacon, nelfilcon A, omafilcon A, ocufilcon B, and nesofilcon A) were evaluated. Four CLs of each type were soaked in lysozyme solution for 16 hours at 37°C. Lysozyme-coated lenses were then placed in vials with 1.5 mL of artificial tear solution containing I-labeled albumin for 16 hours at 37°C with shaking. Four uncoated lenses of each type were used as controls. Lenses soaked in radiolabeled albumin were rinsed in a phosphate-buffered saline solution, and radioactive counts were measured directly on lenses using a gamma counter. Albumin uptake on lenses was measured using a calibration curve by plotting radioactive counts versus protein concentration. Results are reported as mean ± SD. Lysozyme-coated etafilcon A lenses exhibited lower levels of deposited albumin than uncoated etafilcon A lenses (58 ± 12 vs. 84 ± 5 ng/lens; P albumin adsorption between control (uncoated) and lysozyme-coated polymacon (105 ± 10 vs. 110 ± 34 ng/lens), nelfilcon A (51 ± 7 vs. 42 ± 20 ng/lens), omafilcon A (90 ± 20 vs. 80 ± 38 ng/lens), ocufilcon B (87 ± 20 vs. 115 ± 50 ng/lens), and nesofilcon A (170 ± 29 vs. 161 ± 10 ng/lens) lens materials (P > .05). Uncoated nesofilcon A lenses deposited the highest amount of albumin when compared with other uncoated lenses (P albumin, which may potentially be beneficial to CL wearers.

  6. Acanthamoeba Species Keratitis in a Soft Contact Lens Wearer Molecularly Linked to Well Water

    Directory of Open Access Journals (Sweden)

    Samira Mubareka

    2006-01-01

    Full Text Available Acanthamoeba species keratitis has been associated with soft contact lens wear. In the present report, an epidemiological link was established between the patient's isolate and well water from the home using molecular methods. To the authors' knowledge, this is the first case in Canada where such a link has been established. Primary care practitioners and specialists, including ophthalmologists and infectious diseases specialists, must maintain a high degree of clinical suspicion in soft contact lens wearers with keratitis unresponsive to conventional topical and systemic treatment.

  7. Sustained Ocular Delivery of Ciprofloxacin Using Nanospheres and Conventional Contact Lens Materials

    Science.gov (United States)

    Garhwal, Rahul; Shady, Sally F.; Ellis, Edward J.; Ellis, Jeanne Y.; Leahy, Charles D.; McCarthy, Stephen P.; Crawford, Kathryn S.

    2012-01-01

    Purpose. To formulate conventional contact lenses that incorporate nanosphere-encapsulated antibiotic and demonstrate that the lenses provide for sustained antibacterial activity. Methods. A copolymer composed of pullulan and polycaprolactone (PCL) was used to synthesize core-shell nanospheres that encapsulated ciprofloxacin. Bactericidal activity of the nanosphere-encapsulated ciprofloxacin (nanosphere/cipro) was tested by using liquid cultures of either Staphylococcus aureus or Pseudomonas aeruginosa. Nanosphere/cipro was then incorporated into HEMA-based contact lenses that were tested for growth inhibition of S. aureus or P. aeruginosa in liquid cultures inoculated daily with fresh bacteria. Lens designs included thin or thick lenses incorporating nanosphere/cipro and ciprofloxacin-HCl-soaked Acuvue lenses (Acuvue; Johnson & Johnson Vision Care, Inc., Jacksonville, FL). Results. Less than 2 μg/mL of nanosphere/cipro effectively inhibited the proliferation of cultures inoculated with 107 or 108 bacteria/mL of S. aureus and P. aeruginosa, respectively. HEMA-based contact lenses polymerized with nanosphere/cipro were transparent, effectively inhibited the proliferation of greater than 107/mL of bacteria added daily over 3 days of culture, and killed up to 5 × 109 total microbes in a single inoculation. A thicker lens design provided additional inhibition of bacterial growth for up to 96 hours. Conclusions. Core-shell nanospheres loaded with an antibiotic can be incorporated into a conventional, transparent contact lens and provide for sustained and effective bactericidal activity and thereby provide a new drug delivery platform for widespread use in treating ocular disorders. PMID:22266514

  8. Influence of simulated bone-implant contact and implant diameter on secondary stability: a resonance frequency in vitro study.

    Science.gov (United States)

    Veltri, Mario; González-Martín, Oscar; Belser, Urs C

    2014-08-01

    This study tested the hypothesis of no differences in resonance frequency for standardized amounts of simulated bone-implant contact around implants with different diameters. In addition, it was evaluated if resonance frequency is able to detect a difference between stable and rotation mobile ("spinning") implants. Implants with diameters of 3.3, 4.1 and 4.8 mm were placed in a purposely designed metal mould where liquid polyurethane resin was then poured to obtain a simulated bone-implant specimen. By regulating the mould, it was possible to create the following simulated bone-implant contact groups: 3.3 mm (198.6 mm(2)); 4.1 mm (198.8 mm(2)); 4.8 mm (200.2 mm(2)); 4.8 mm (231.7 mm(2)); 4.8 mm (294.7 mm(2)). Each group included 10 specimens. After resin setting, resonance frequency was measured. On the last group, measurements were repeated after establishing implant rotational mobility. One-way ANOVA tests with post hoc comparisons, a Pearson's correlation coefficient and a t-test for repeated measurements were used to evaluate statistically significant differences. Implants with different diameters but with the same amount of simulated osseointegration revealed no differences in resonance frequency. On the contrary, an increase of simulated bone-implant contact resulted in significantly higher resonance frequency. A clear direct linear correlation resulted between resonance frequency and simulated bone-implant contact. Furthermore, a significant difference resulted between resonance frequency measured before and after creation of rotational mobility. Within the conditions of this study, the secondary stability was correlated with the simulated bone-implant contact. In addition, resonance frequency was able to discern between stable and rotation mobile implants. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Thermal characterization of radiation processed contact lens material

    International Nuclear Information System (INIS)

    Varshney, L.; Choughule, S.V.

    1998-01-01

    Differential scanning calorimetry (DSC), thermomechanical analysis (TMA) and thermogravimetry analysis (TGA) were used to characterize radiation processed contact lens gel material of 2-hydroxy ethyl methacrylate(HEMA). DSC revealed two types of water in the gels. DSC and TGA in combination were used to quantitate the percentage of different types of the water in the gel material. Temperature expansion coefficients values indicate more dimensions stability in the radiation processed lenses of similar water contents. (author)

  10. Effect of radial head implant shape on joint contact area and location during static loading.

    Science.gov (United States)

    Shannon, Hannah L; Deluce, Simon R; Lalone, Emily A; Willing, Ryan; King, Graham J W; Johnson, James A

    2015-04-01

    To examine the effect of implant shape on radiocapitellar joint contact area and location in vitro. We used 8 fresh-frozen cadaveric upper extremities. An elbow loading simulator examined joint contact in pronation, neutral rotation, and supination with the elbow at 90° flexion. Muscle tendons were attached to pneumatic actuators to allow for computer-controlled loading to achieve the desired forearm rotation. We performed testing with the native radial head, an axisymmetric implant, a reverse-engineered patient-specific implant, and a population-based quasi-anatomic implant. Implants were inserted using computer navigation. Contact area and location were quantified using a casting technique. We found no significant difference between contact locations for the native radial head and the 3 implants. All of the implants had a contact area lower than the native radial head; however, only the axisymmetric implant was significantly different. There was no significant difference in contact area between implant shapes. The similar contact areas and locations of the 3 implant designs suggest that the shape of the implant may not be important with respect to radiocapitellar joint contact mechanics when placed optimally using computer navigation. Further work is needed to explore the sensitivity of radial head implant malpositioning on articular contact. The lower contact area of the radial head implants relative to the native radial head is similar to previous benchtop studies and is likely the result of the greater stiffness of the implant. Radial head implant shape does not appear to have a pronounced influence on articular contact, and both axisymmetric and anatomic metal designs result in elevated cartilage stress relative to the intact state. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. [Eyelid hygiene for contact lens wearers with blepharitis. Comparative investigation of treatment with baby shampoo versus phospholipid solution].

    Science.gov (United States)

    Khaireddin, R; Hueber, A

    2013-02-01

    Blepharitis due to Meibom gland dysfunction (MGD) is presumed to be one of the main reasons for dry eye symptoms which occur in up to 50% of contact lens users. Thus, MGD presumably plays an important role in dry eye in contact lens wearers. In the present prospective, randomized and double blind trial the efficacy of two established treatment options for MGD and blepharitis was evaluated in symptomatic contact lens wearers. In this prospective, randomized 2-centre trial 53 symptomatic contact lens wearers suffering from blepharitis were included. Patients were randomly selected for two treatment groups: group A performed lid margin hygiene using the commonly recommended mild baby shampoo (Bübchen Kinder Shampoo-extra augenmild, Bübchen Werk Ewald Hermes Pharmazeutische Fabrik GmbH, Soest, Germany) and group B performed lid margin hygiene using a phospholipid-liposome solution specially designed for lid hygiene (Blepha Cura, Optima, Moosburg/Wang, Germany), each for 4 weeks. Before as well as 4 weeks after initiation of this study the following tests were performed: standardized subjective assessment using the ocular surface disease index, non-invasive break-up time (NIBUT) and objective evaluation of lid-parallel conjunctival folds (LIPCOF) and further lid margin criteria by double blinded evaluation of slit lamp photographs. Of the 53 symptomatic contact lens wearers suffering from blepharitis 21 (39,6%) were randomly selected for treatment group A and 32 (60.4%) for group B. In both treatment groups there was objective and subjective improvement of symptoms of dry eye in contact lens wearers. Interestingly, there was a significantly greater improvement, subjective as well as objective, in treatment group B which used the phospholipidliposome solution for lid margin hygiene compared to group A using baby shampoo. Although both therapies improved symptoms of dry eye due to blepharitis in symptomatic contact lens wearers, patients using phospholipid

  12. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant.

    Science.gov (United States)

    Ye, Clara; Patel, Cajal K; Momont, Anna C; Liu, Yao

    2018-06-01

    We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL) (Visian ICL™, Staar Inc., Monrovia, CA) implant that resulted in advanced visual field loss. A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL) placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP) in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss.

  13. A novel in-vitro method for assessing contact lens surface dewetting: Non-invasive keratograph dry-up time (NIK-DUT).

    Science.gov (United States)

    Marx, Sebastian; Sickenberger, Wolfgang

    2017-12-01

    This study was designed to develop a novel technique called non-invasive keratograph dry-up time (NIK-DUT), which used an adapted corneal topographer, to analyse in-vitro contact lens surface dewetting and the effects of combinations of lenses and lens care solutions on dewetting. Variables were assessed to optimise sensitivity and reproducibility. To validate the method, in-vitro dewetting of silicone hydrogel contact lenses (balafilcon A, comfilcon A, lotrafilcon A, lotrafilcon B and senofilcon A) was tested. All lens types were soaked in OPTI-FREE ® PureMoist ® Multipurpose Disinfecting Solution (OFPM) and Sensitive Eyes ® Saline Solution. The mean NIK-DUT, defined as drying of 25% of the placido ring measurement segments (NIK-DUT_S25), was calculated for each lens/lens solution combination and a visual map constructed representing the time and location of the dry-up event. Optimal conditions for NIK-DUT measurement included mounting onto a glass stage with a surface geometry of r=8.5mm, e=0, and measuring with high intensity red or white illumination. This method detected significant differences in contact lens dewetting with different lens soaking solutions. NIK-DUT_S25 for all lenses was longer when pre-soaked in OFPM versus saline. Visual analysis showed that dewetting of contact lenses was not uniform across surfaces and differed between test solutions. NIK-DUT is suitable for detecting differences in dewetting among various contact lenses and lens-care combinations. NIK-DUT can quantify the dewetting of large areas of lens surfaces with little subjective influence. Lens care solutions containing surface-active wetting agents were found to delay surface dewetting of silicone hydrogel lenses. Copyright © 2017. Published by Elsevier Ltd.

  14. Intraocular pressure measurement over soft contact lens by rebound tonometer:a comparative study

    Directory of Open Access Journals (Sweden)

    Senay Asik Nacaroglu

    2015-06-01

    Full Text Available AIM: To evaluate the intraocular pressure (IOP measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry (GAT.METHODS: Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens (RTCL, RT respectively and by GAT, as well as their central corneal thickness (CCT by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis.RESULTS: Mean IOP values measured by RTCL, RT and GAT were 15.68±3.7, 14.50±3.4 and 14.16±2.8 (P<0.001, respectively. Mean IOP by RTCL was significantly higher than the measurements implemented by RT and GAT (P<0.001, while there was no difference between the measurements by GAT and RT (P=0.629. There was a good level of positive correlation between GAT and RTCL as well as RT (r=0.786 P<0.001, r=0.833 P<0.001, respectively. We have observed that CCT increase did not show any correlation with the differences of the measurements between RTCL and RT (P=0.329, RTCL and GAT (P=0.07 as well as RT and GAT (P=0.189 in linear regression model.CONCLUSION: The average of the measurements over contact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population.

  15. Bone-Implant Contact around Crestal and Subcrestal Dental Implants Submitted to Immediate and Conventional Loading

    Directory of Open Access Journals (Sweden)

    Ana Emília Farias Pontes

    2014-01-01

    Full Text Available The present study aims to evaluate the influence of apicocoronal position and immediate and conventional loading in the percentage of bone-implant contact (BIC. Thus, 36 implants were inserted in the edentulous mandible from six dogs. Three implants were installed in each hemimandible, in different positions in relation to the ridge: Bone Level (at crestal bone level, Minus 1 (one millimeter apical to crestal bone, and Minus 2 (two millimeters apical to crestal bone. In addition, each hemimandible was submitted to a loading protocol: immediate (prosthesis installed 24 hours after implantation or conventional (prosthesis installed 120 days after implantation. Ninety days after, animals were killed, and implant and adjacent tissues were prepared for histometric analysis. BIC values from immediate loaded implants were 58.7%, 57.7%, and 51.1%, respectively, while conventional loaded implants were 61.8%, 53.8%, and 68.4%. Differences statistically significant were not observed among groups (P=0.10, ANOVA test. These findings suggest that different apicocoronal positioning and loading protocols evaluated did not interfere in the percentage of bone-implant contact, suggesting that these procedures did not jeopardize osseointegration.

  16. [Laser magnetotherapy after cataract extraction with implantation of intraocular lens].

    Science.gov (United States)

    Maksimov, V Iu; Zakharova, N V; Maksimova, I S; Golushkov, G A; Evseev, S Iu

    2002-01-01

    Effects of low-intensive laser and alternating magnetic field on the course of the postoperative period were studied in patients with exudative reaction after extracapsular cataract extraction with implantation of intraocular lens (IOL). The results are analyzed for 148 eyes with early exudative reaction after IOL implantation (136 patients aged 42-75 years). The patients were observed for up to 6 months. The treatment efficiency was evaluated by the clinical picture of inflammatory reaction, visual acuity, and results of biochemical analysis of the lacrimal fluid (the ratio of lipid peroxidation products to antioxidants in cell membrane). The course of the postoperative period was more benign and recovery sooner in patients of the main group in comparison with the control.

  17. Aspergillus tamarii keratitis in a contact lens wearer

    Directory of Open Access Journals (Sweden)

    Juan Cuadros

    2018-03-01

    Full Text Available Keratitis produced by Aspergillus tamarii has been previously described associated to an ocular injury. We report a case in a contact lens wearer with a history of previous bilateral myopic LASIK ablation, bilateral intracorneal rings and vitrectomy and scleral buckling in his left eye. The fungus could be quickly identified combining phenotype, microscopy and mass spectrometry. Treatment with intravenous amphotericin, oral voriconazole, and topical amphotericin and natamycin and voriconazole was needed for corneal preservation.

  18. Changes in stereoacuity following implantable Collamer lens implantation in patients with myopia

    Directory of Open Access Journals (Sweden)

    Sudarshan Khokhar

    2015-01-01

    Full Text Available The study evaluated the impact of implantable Collamer lens (ICL implantation on stereoacuity in myopes in a retrospective case series. Ninety-five eyes of 48 patients were recruited. Distance and near stereoacuity were measured using distance Randot stereotest and TNO test, respectively, before surgery and at 4 weeks postoperatively. Mean age of the patients was 23.67 ± 3.7 years. Mean uncorrected distance visual acuity (UDVA was 1.28 ± 0.37 logarithm of the minimum angle of resolution (logMAR (median: 1.3; range: 0.3-1.8, and median best-corrected distance visual acuity (BDVA was 0.18 logMAR (range: 0-0.6. There was a significant improvement in both UDVA and BDVA postsurgery (P < 0.001; Wilcoxon signed rank test. The overall improvement in stereopsis was observed in 15/48 (31.25% and 13/48 (27.10% subjects for near and distance, respectively, with no significant difference between the two (P = 0.82; Fisher′s exact test. Among stereoblind individuals, the odd′s ratio for near stereoacuity to improve in comparison to distance stereoacuity was 8.85 (95% confidence interval: 1.68-46.70; P = 0.01. ICL implantation for refractive correction aided stereoacuity improvement in myopes more so for near.

  19. Contact of dual mobility implants: effects of cup wear and inclination.

    Science.gov (United States)

    Uddin, M S

    2015-01-01

    Cup wear and inclination on the pelvic bone are significant factors, which change the contact of the articulating surfaces, thus, impacting the long-term performance of hip implants. This paper presents a finite element (FE) analysis of the contact of the dual mobility implants under the influence of cup wear and inclination. A 3D FE model of the implant was developed with the application of equivalent physiological loading and boundary conditions. Effects of cup inclination angle ranging from 45° to 60° and the wear depth ranging from 0 to 2.46 mm equivalent to up to 30 years of the implant's life on the contact pressure and von Mises stress were investigated. Simulation results show that the contact pressure and von Mises stress decrease significantly with a modest wear depth and remains quite in-sensitive to the cup inclination angle and wear depth up to 1.64 mm. With wear depth further up to 2.46 mm, the cup thickness (i.e. cup thinning on worn region) may be more predominant than increasing of contact area between the cup and the head. The wear on the inner surface of the cup is found to rule out the overall contact pressure and stress in the implant. Furthermore, individual and combined effects of both important parameters are analysed and discussed with respect to available clinical/laboratory studies.

  20. Clinical application of femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract

    Directory of Open Access Journals (Sweden)

    Qing-Song Gao

    2018-02-01

    Full Text Available AIM:To evaluate the effect of femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract. METHODS: Totally 86 cases(106 eyesof patients with double cataract in our hospital from January 2016 to January 2017 were selected, including 49 cases(59 eyeswere set as the observation group(treated with femtosecond laser assisted phacoemulsification combined with triple-focus intraocular lens implantation, and 37 cases(47 eyeswere set as the control group(received traditional phacoemulsification combined with triple-focus intraocular lens implantation. Corneal endothelial cell density, cumulative dissipated energy(CDE, distant and near visual accommodation before and after operation were compared between the two groups, postoperative complications were observed. RESULTS: The preoperative corneal endothelial cell density of two groups had no significant difference(P>0.05. The corneal endothelial cell density of two groups significantly decreased at postoperative 1wk, with statistic significance within groups(PPPPPP>0.05. The incidence of glare and halo in the observation group was 10.2% and 8.5% in the control group, and are in the patients whose age was above 60 years old, there was no significant difference between the two groups(P>0.05. CONCLUSION: Femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract can not only improve curative effect, but also provide high safety, while the adverse events including glare, halo and other adverse visual circumstances should be considered after triple-focus intraocular lens implantation.

  1. Study on the surface of fluorosilicone acrylate RGP contact lens treated by low-temperature nitrogen plasma

    International Nuclear Information System (INIS)

    Ren Li; Yin Shiheng; Zhao Lianna; Wang Yingjun; Chen Hao; Qu Jia

    2008-01-01

    In order to improve the surface hydrophilicity of fluorosilicone acrylate rigid gas permeable (RGP) contact lens, low temperature nitrogen plasma was used to modify the lens surface. Effects of plasma conditions on the surface structures and properties were investigated. Results indicated that the surface hydrophilicity of RGP contact lens was significantly improved after treatment. X-ray photoelectron spectroscopy (XPS) results showed that the nitrogen element was successfully incorporated into the surface. Furthermore, some new bonds such as N-C=O, F - and silicate were formed on the lens surface after nitrogen plasma treatment, which could result in the improvement of the surface hydrophilicity. Scanning electronic microscope (SEM) results indicated that nitrogen plasma with moderate power could make the surface smoother in some degree, while plasma with higher power could etch the surface

  2. Tunnel oxide passivated contacts formed by ion implantation for applications in silicon solar cells

    International Nuclear Information System (INIS)

    Reichel, Christian; Feldmann, Frank; Müller, Ralph; Hermle, Martin; Glunz, Stefan W.; Reedy, Robert C.; Lee, Benjamin G.; Young, David L.; Stradins, Paul

    2015-01-01

    Passivated contacts (poly-Si/SiO x /c-Si) doped by shallow ion implantation are an appealing technology for high efficiency silicon solar cells, especially for interdigitated back contact (IBC) solar cells where a masked ion implantation facilitates their fabrication. This paper presents a study on tunnel oxide passivated contacts formed by low-energy ion implantation into amorphous silicon (a-Si) layers and examines the influence of the ion species (P, B, or BF 2 ), the ion implantation dose (5 × 10 14  cm −2 to 1 × 10 16  cm −2 ), and the subsequent high-temperature anneal (800 °C or 900 °C) on the passivation quality and junction characteristics using double-sided contacted silicon solar cells. Excellent passivation quality is achieved for n-type passivated contacts by P implantations into either intrinsic (undoped) or in-situ B-doped a-Si layers with implied open-circuit voltages (iV oc ) of 725 and 720 mV, respectively. For p-type passivated contacts, BF 2 implantations into intrinsic a-Si yield well passivated contacts and allow for iV oc of 690 mV, whereas implanted B gives poor passivation with iV oc of only 640 mV. While solar cells featuring in-situ B-doped selective hole contacts and selective electron contacts with P implanted into intrinsic a-Si layers achieved V oc of 690 mV and fill factor (FF) of 79.1%, selective hole contacts realized by BF 2 implantation into intrinsic a-Si suffer from drastically reduced FF which is caused by a non-Ohmic Schottky contact. Finally, implanting P into in-situ B-doped a-Si layers for the purpose of overcompensation (counterdoping) allowed for solar cells with V oc of 680 mV and FF of 80.4%, providing a simplified and promising fabrication process for IBC solar cells featuring passivated contacts

  3. Patient characteristics, diagnosis, and treatment of non-contact lens related Acanthamoeba keratitis.

    Science.gov (United States)

    Sharma, S; Garg, P; Rao, G N

    2000-10-01

    To review the clinical characteristics, diagnosis, and visual outcome in patients with non-contact lens related Acanthamoeba keratitis and compare the findings with reported series of contact lens associated Acanthamoeba keratitis. Medical and microbiology records of 39 consecutive patients with a diagnosis of Acanthamoeba keratitis, at a tertiary eyecare centre in India between January 1996 and June 1998, were analysed retrospectively. A majority of the patients presented with poor visual acuity and large corneal stromal infiltrates (mean size 38.20 (SD 26. 18) mm). A predisposing factor was elicited in 19/39 (48.7%) patients (trauma 15, dirty water splash three, leaf juice one). None of the patients had worn contact lenses. Most patients (26/39 (66. 6%)) came from a low socioeconomic background. Complaint of severe pain was not a significant feature and radial keratoneuritis was seen in 1/39 (2.5%) patients. A ring infiltrate was present in 41.1% of cases. A clinical diagnosis of fungal keratitis was made in 45% of the patients before they were seen by us. However, all patients were diagnosed microbiologically at our institute based on demonstration of Acanthamoeba cysts in corneal scrapings (34/39) and/or culture of Acanthamoeba (34/39). Treatment with biguanides (PHMB, 15/38 (39.4%), PHMB with CHx, 23/38 (60.5%), one patient did not return for treatment) resulted in healing with scar formation in 27 out of 31(87.0%) followed up patients (mean time to healing 106.9 days). Overall visual outcome was poor with no statistical difference between cases diagnosed within 30 days (early) or 30 days after (late) start of symptoms. The visual outcome in cases requiring tissue adhesive (five) and keratoplasty (three) was also poor. This is thought to be the largest series of cases of Acanthamoeba keratitis in non-contact lens wearers. In such cases, the disease is advanced at presentation in most patients, pathognomonic clinical features are often not seen, disease

  4. KNOWLEDGE, ATTITUDE AND PRACTICE OF CONTACT LENS USERS AMONG MEDICAL COLLEGE STUDENTS IN BANGALORE

    Directory of Open Access Journals (Sweden)

    Sujatha

    2015-09-01

    Full Text Available INTRODUCTION: The use of contact lens (CL for the correction of refractive errors, cosmetic use and their usage as a therapeutic modality for corneal pathologies has increased many fold over the years. The present study was conducted with the aim to find the knowledge , attitude and pattern of CL use amongst medical college students and to highlight the complications and the correct method to be followed. MATERIALS AND METHODS: This study included 520college students out of which 114 students who have worn contact lens for any period were included for the study. RESULTS: Results showed that 94.7% of the CL users use the daily wear soft contact lens’ most quoted reasons of usage were comfort and convenience (59.6% with cosmetic benefit (29.8% as the next most common reply. Common complaints were that of general discomfort (foreign body sensation, dry eyes and watering eyes. With the advent of e commerce 26.3% of students are buying lenses are online. CONCLUSION: Educated use of CLs amongst its users is advised in view of the symptoms and associated complications that may occur. Electronic media is playing a commendable role in the sales and educating the buyers about do’s and don’t’s of contact lens use

  5. Reverse pupillary block after implantation of a scleral-sutured posterior chamber intraocular lens: a retrospective, open study.

    Science.gov (United States)

    Bang, Seung Pil; Joo, Choun-Ki; Jun, Jong Hwa

    2017-03-29

    To report the clinical features of patients with reverse pupillary block (RPB) after scleral-sutured posterior chamber intraocular lens (PC IOL) implantation and biometric changes after laser peripheral iridotomy (LPI). Eight patients attending our hospital's ophthalmology outpatient clinic, who developed RPB after implantation of a scleral-sutured PC IOL due to subluxation of the crystalline lens or IOL, were investigated in this retrospective, observational study. Preoperative evaluations showed angle pigmentation in all cases and iridodonesis in 2 cases. Two subjects had used an α 1A -adrenoceptor antagonist for benign prostatic hyperplasia. Pars plana or anterior partial vitrectomy was performed in all cases. All eyes showed an extremely deep anterior chamber, a concave iris configuration, and contact between the IOL optic and the iris at the pupillary margin. Pupil capture was detected in 2 cases. The mean (± SD) anterior chamber angle (ACA) was 89.91 ± 10.06°, and the anterior chamber depth (ACD) was 4.42 ± 0.16 mm before LPI. After LPI, the iris immediately became flat with a decreased ACA (51.70 ± 2.59°; P = 0.018) and ACD (4.14 ± 0.15 mm; P = 0.012). After LPI, the intraocular pressure decreased from 19.75 ± 3.77 mmHg to 15.63 ± 4.30 mmHg (P = 0.011), and the spherical equivalent decreased from -0.643 ± 0.385 D to - 0.875 ± 0.505 D (P = 0.016). Concomitant vitrectomy, angle pigmentation, and iridodonesis may be risk factors for RPB after scleral-sutured PC IOL implantation. LPI is effective for relieving the RPB.

  6. Determination of the total attenuation coefficient for six contact lens materials using the Beer-Lambert law.

    Science.gov (United States)

    Hull, C C; Crofts, N C

    1996-03-01

    The Beer-Lambert law has been used to determine the total attenuation coefficient, mu t, of three hard and three soft contact lens materials. The three hard contact lens materials were PMMA, Polycon II and Boston IV whereas the 3 soft materials were chosen with differing water contents of 38, 55 and 70%, respectively. The total attenuation coefficients of all six materials were obtained from measurements of the axial transmission at 632.8 nm of a series of plano powered lenses varying in axial thickness from 0.5 to 3.5 mm. The value of the total attenuation coefficient depends on both scattering and absorption and hence PMMA and Boston IV, which both incorporated a handling tint, showed significantly higher values (P 0.5) was found between any of the hydrated soft contact lens materials tested.

  7. Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry.

    Science.gov (United States)

    Hoffmann, Esther M; Grus, Franz-H; Pfeiffer, Norbert

    2004-03-23

    The new Ocular Dynamic Contour Tonometer (DCT), investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland) allows simultaneous recording of intraocular pressure (IOP) and ocular pulse amplitude (OPA). It was the aim of this study to compare the IOP results of this new device with Goldmann tonometry. Furthermore, IOP and OPA measured with the new slitlamp-mounted DCT were compared to the IOP and OPA measured with the hand-held SmartLens,a gonioscopic contact lens tonometer (ODC Ophthalmic Development Company AG, Switzerland). Nineteen healthy subjects were included in this study. IOP was determined by three consecutive measurements with each of the DCT, SmartLens, and Goldmann tonometer. Furthermore, OPA was measured three times consecutively by DCT and SmartLens. No difference (P = 0.09) was found between the IOP values by means of DCT (mean: 16.6 mm Hg, median: 15.33 mm Hg, SD: +/- 4.04 mm Hg) and Goldmann tonometry (mean: 16.17 mm Hg, median: 15.33 mm Hg, SD: +/- 4.03 mm Hg). The IOP values of SmartLens (mean: 20.25 mm Hg, median: 19.00 mm Hg, SD: +/- 4.96 mm Hg) were significantly higher (P = 0.0008) both from Goldmann tonometry and DCT. The OPA values of the DCT (mean: 3.08 mm Hg, SD: +/- 0.92 mm Hg) were significantly lower (P = 0.0003) than those obtained by SmartLens (mean: 3.92 mm Hg, SD: +/- 0.83 mm Hg). DCT was equivalent to Goldmann applanation tonometry in measurement of IOP in a small group of normal subjects. In contrast, SmartLens (contact lens tonometry) gave IOP readings that were significantly higher compared with Goldmann applanation tonometer readings. Both devices, DCT and SmartLens provide the measurement of OPA which could be helpful e.g. for the management of glaucoma.

  8. Safety and effect of femtosecond laser-assisted cataract surgery combined with Cionni capsular tension ring implantation in the management of traumatic lens subluxation

    Directory of Open Access Journals (Sweden)

    Jia-Hui Chen

    2017-07-01

    Full Text Available AIM:To investigate the safety and effect of femtosecond laser-assisted cataract surgery with Cionni modified capsular tension ring(MCTRimplantation in the management of traumatic lens subluxation.METHODS: Totally 11 patients(11 eyeswith traumatic lens subluxation were divided into three groups according to the severity of lens dislocation, ranging from 90° to 120°(4 eyes, 120° to 180°(5 eyesand 180° to 270°(2 eyes. The contact LenSx femtosecond laser cataract surgery platform was applied to create the capsulotomy, prepare nuclear fragmentation and make corneal wound creation. Anterior vitrectomy was performed in some patients during the surgery. After capsular retractors insertion and phacoemulsification, the MCTR was inserted to the capsular bag and fixed to the sclera. Finally, the IOL was implanted into the capsular bag. Postoperative visual acuity, intra- and post-operative complications, anterior capsular opening, IOL and MCTR position and intraocular pressure(IOPwere assessed.RESULTS:The duration of follow-up was 2mo. All the operations were completed successfully. Five eyes underwent cataract surgery combined with anterior vitrectomy. Four eyes had been inserted with 2-eyelet MCTR and seven eyes with 1-eyelet MCTR. The best corrected visual acuity(BCVAafter operation was better than 0.5 in 4 eyes, between 0.3 and 0.5 in 3 eyes, between 0.1 and 0.3 in 3 eyes, and less than 0.1 in 1 eye. Compared with preoperative BCVA, the difference was statistically significant(PCONCLUSION:Femtosecond laser-assisted cataract surgery can improve the success rate of capsulorhexis, and reduce the difficulty of nuclear fragmentation. Femtosecond laser-assisted cataract surgery combined with MCTR implantation is an ideal surgical method for traumatic lens subluxation.

  9. Analysis on shift and rotation of intraocular lens after phakic collamer lens implantation

    Directory of Open Access Journals (Sweden)

    Yuan-Yuan Lu

    2016-05-01

    Full Text Available Recently, the incidence of myopia increases year by year. The effectiveness of refractive surgery for the correction of ametropia is widely recognized with rapid development of ophthalmic microsurgery. The laser in situ keratomileusis(LASIKhas been accepted as a regular refractive surgery technique to correct mild and moderate myopia. However, it shows inadequacy in ability to correct high refractive errors, and in patients with thin cornea and keratoconus. In 1993, Staar Surgical(A.G. Nidauintroduced a modified intraocular collamer lens(ICLfor the correction of high myopia, which emerged as a safe and effective operation for moderate or high myopia gradually. Although it has already been proved that ICL has safety and efficacy for the correction of high myopia, several studies reported dislocation and rotation of ICL after implantation, which led decreased vision and poor satisfaction. In severe cases, secondary glaucoma, anterior subcapsular cataract happened consequentially. These potential complications have drawn more and more attention by the majority of physicians and scholars. This paper aims to discuss the potential cause of shift and rotation of ICLs after implantation.

  10. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation.

    Science.gov (United States)

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  11. Activity of a melimine derived peptide Mel4 against Stenotrophomonas, Delftia, Elizabethkingia, Burkholderia and biocompatibility as a contact lens coating.

    Science.gov (United States)

    Dutta, Debarun; Zhao, Timothy; Cheah, Kai Bing; Holmlund, Larke; Willcox, Mark D P

    2017-06-01

    To determine the antimicrobial activity of the melimine derived peptide Mel4 against Delftia, Stenotrophomonas, Elizabethkingia, Burkholderia and to investigate biocompatibility of Mel4 as an antimicrobial coating on contact lenses in animals and humans. In vitro antimicrobial activity of Mel4 was determined against the four Gram negative bacteria by investigating growth curves for 24h followed by viable counts to determine the minimum inhibitory concentration (MIC). Contact lenses were coated by covalently binding Mel4, characterized by amino acid analysis, and were investigated for changes in lens parameters. Safety of Mel-4 coated lenses were determined in a rabbit model of daily contralateral wear. A prospective, randomised, double-masked, contralateral, 1week daily wear human clinical trial was used to evaluate subjective responses and ocular physiology. Mel4 was active against all the bacteria tested (MIC 50 ranged from 31-1000μgml -1 ) and produced an antimicrobial surface on contact lenses. Mel4-coating resulted hydrophilic surface without any significant change in contact lens parameters, and showed no signs of cytotoxicity or ocular irritation during rabbit wear. During human clinical trial, there were no differences between Mel4 coated and uncoated contact lenses in lens performance indicators and ocular signs such as corneal fluorescein staining. Mel4 and control uncoated lenses had no differences in ocular symptoms during lens wear. Mel4 has achieved antimicrobial activity against variety of Gram negative bacteria that are often resistant to the action of cationic peptides and have been implicated in contact lens related adverse events. Mel4-coated contact lenses were safe to wear. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  12. Fitting an MSD (mini scleral design) rigid contact lens in advanced keratoconus with INTACS.

    Science.gov (United States)

    Dalton, Kristine; Sorbara, Luigina

    2011-12-01

    Keratoconus is a bilateral degenerative disease characterized by a non-inflammatory, progressive central corneal ectasia (typically asymmetric) and decreased vision. In its early stages it may be managed with spectacles and soft contact lenses but more commonly it is managed with rigid contact lenses. In advanced stages, when contact lenses can no longer be fit, have become intolerable, or corneal damage is severe, a penetrating keratoplasty is commonly performed. Alternative surgical techniques, such as the use of intra-stromal corneal ring segments (INTACS) have been developed to try and improve the fit of rigid contact lenses in keratoconic patients and avoid penetrating keratoplasties. This case report follows through the fitting of rigid contact lenses in an advanced keratoconic cornea after an INTACS procedure and discusses clinical findings, treatment options, and the use of mini-scleral and scleral lens designs as they relate to the challenges encountered in managing such a patient. Mini-scleral and scleral lenses are relatively easy to fit, and can be of benefit to many patients, including advanced keratoconic patients, post-INTAC patients and post-penetrating keratoplasty patients. 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  13. Evaluation of the tightness of contact between 
limbal sclera tunnel and tube following Ahmed 
glaucoma valve implantation.

    Science.gov (United States)

    Holló, Gábor; Naghizadeh, Farzaneh

    2013-01-01

    To investigate whether the tightness of contact between the tube and the limbal sclera tunnel can be evaluated with high-magnification anterior segment optical coherence tomography (OCT) imaging following Ahmed glaucoma valve implantation. Tightness between the tube and the limbal sclera tunnel was investigated with the CAM-L cornea lens adapter of the Optovue Fourier-domain OCT (RTVue-OCT) for 21 uncomplicated Ahmed glaucoma valves implanted in 20 eyes of 19 patients with glaucoma. Nineteen valves were implanted 4 to 124 months earlier (late postoperative cases) and 2 valves 1 day prior to the imaging (early postoperative cases). All valves were introduced into the anterior chamber via a limbal sclera tunnel. The limbal intratunnel part of the tube was successfully imaged in all but 2 cases where an additional full-thickness sclera patch was used. In 14 cases, the contact was tight without tube compression. In 
5 cases, the tube was partially compressed but remained open in the limbal sclera tunnel, and redilated behind the limbus. No case with loose contact or peritubular filtration was seen. The posterior run of the tube was successfully imaged in all 19 cases without a full-thickness sclera patch. High-magnification imaging with the CAM- L anterior segment adapter of the RTVue-OCT allows detailed examination of the limbal insertion area of tubes in both the early and late postoperative periods. Therefore this method may potentially be applied for detection of complications related to tube insertion after glaucoma drainage device surgery.

  14. Protein deposition on a lathe-cut silicone hydrogel contact lens material.

    Science.gov (United States)

    Subbaraman, Lakshman N; Woods, Jill; Teichroeb, Jonathan H; Jones, Lyndon

    2009-03-01

    To determine the quantity of total protein, total lysozyme, and the conformational state of lysozyme deposited on a novel, lathe-cut silicone hydrogel (SiHy) contact lens material (sifilcon A) after 3 months of wear. Twenty-four subjects completed a prospective, bilateral, daily-wear, 9-month clinical evaluation in which the subjects were fitted with a novel, custom-made, lathe-cut SiHy lens material. The lenses were worn for three consecutive 3-month periods, with lenses being replaced after each period of wear. After 3 months of wear, the lenses from the left eye were collected and assessed for protein analysis. The total protein deposited on the lenses was determined by a modified Bradford assay, total lysozyme using Western blotting and the lysozyme activity was determined using a modified micrococcal assay. The total protein recovered from the custom-made lenses was 5.3 +/- 2.3 microg/lens and the total lysozyme was 2.4 +/- 1.2 microg/lens. The denatured lysozyme found on the lenses was 1.9 +/- 1.0 microg/lens and the percentage of lysozyme denatured was 80 +/- 10%. Even after 3 months of wear, the quantity of protein and the conformational state of lysozyme deposited on these novel lens materials was very similar to that found on similar surface-coated SiHy lenses after 2 to 4 weeks of wear. These results indicate that extended use of the sifilcon A material is not deleterious in terms of the quantity and quality of protein deposited on the lens.

  15. The Management of Refractory Dry Eye With Semi-Scleral Contact Lens.

    Science.gov (United States)

    Yuksel, Erdem; Bilgihan, Kamil; Novruzlu, Şahin; Yuksel, Nilay; Koksal, Murat

    2016-05-19

    We presented a case of refractory dry eye management with semi-scleral contact lens. Dry eye was associated with facial nerve (cranial nerve VII) palsy as a result of cerebellopontine angle tumor surgery. She was treated with several topical treatments and punctal plug. Despite the treatments, her symptoms still persisted. Her ophthalmic examination revealed scleral exposure because of lagophthalmos, conjunctival hyperemia, corneal debris, scar, and diffuse punctate epitheliopathy on her right eye. Lissamine green staining showed diffuse conjunctival and corneal staining. Therapeutic semi-scleral lenses were fitted. The corneal findings were resolved and the quality of patient life was improved with the aid of semi-scleral lens after 3 months.

  16. Resultados de implante de lente intraocular en niños Results of intraocular lens implantation in children

    Directory of Open Access Journals (Sweden)

    Nashelly I. Mejía Cruz

    2007-12-01

    Full Text Available En este estudio se describen los resultados obtenidos del implante de lente intraocular en niños, quienes acudieron al servicio de Oftalmología Pediátrica de Instituto Cubano de oftalmología “Ramón Pando Ferrer” con el diagnóstico de catarata de diversas etiologías, en período comprendido entre abril del 2002 al 2005 cuyo seguimiento fue durante un año. En nuestro universo de estudio se determinan algunos parámetros como la edad del paciente, etiología de las cataratas, agudeza visual, defecto refractivo preoperatorio y posoperatorio. Se identificó el poder dióptrico del lente intraocular más frecuente, la presencia de complicaciones durante la cirugía y después de esta. Se evaluaron finalmente, los pacientes que requerían de tratamiento adicional como la capsulotomía con láser o membranectomía quirúrgica. El implante del lente intraocular a temprana edad se relacionó con buenos resultados quirúrgicos: mejoría de la agudeza visual corregida, presentándose el astigmatismo como el error refractivo más frecuente. La complicación transoperatorio y postoperatoria más frecuente fue la membrana inflamatoria, mientras que la complicación posoperatoria más frecuente fue la opacidad de la cápsula posterior.This paper described the results of the intraocular lens implantation performed in children, who had been seen at the Pediatric Ophthalmologic Service of " Ramon Pando Ferrer " Cuban Institute of Ophthalmology and had been diagnosed as having cataract of various etiologies, from April 2002 to April 2005. They were all followed-up for a year. Some parameters like the patient’s age, the etiology of cataract, visual acuity, pre-operative and post-operative refractive defect were considered in our study. The dioptric power of the most common intraocular lens and the most frequent complications during and after surgery were identified. The patients requiring additional treatment such as laser capsulotomy and surgical

  17. A contact mechanics model for ankle implants with inclusion of surface roughness effects

    International Nuclear Information System (INIS)

    Hodaei, M; Farhang, K; Maani, N

    2014-01-01

    Total ankle replacement is recognized as one of the best procedures to treat painful arthritic ankles. Even though this method can relieve patients from pain and reproduce the physiological functions of the ankle, an improper design can cause an excessive amount of metal debris due to wear, causing toxicity in implant recipient. This paper develops a contact model to treat the interaction of tibia and talus implants in an ankle joint. The contact model describes the interaction of implant rough surfaces including both elastic and plastic deformations. In the model, the tibia and the talus surfaces are viewed as macroscopically conforming cylinders or conforming multi-cylinders containing micrometre-scale roughness. The derived equations relate contact force on the implant and the minimum mean surface separation of the rough surfaces. The force is expressed as a statistical integral function of asperity heights over the possible region of interaction of the roughness of the tibia and the talus implant surfaces. A closed-form approximate equation relating contact force and minimum separation is used to obtain energy loss per cycle in a load–unload sequence applied to the implant. In this way implant surface statistics are related to energy loss in the implant that is responsible for internal void formation and subsequent wear and its harmful toxicity to the implant recipient. (paper)

  18. A contact mechanics model for ankle implants with inclusion of surface roughness effects

    Science.gov (United States)

    Hodaei, M.; Farhang, K.; Maani, N.

    2014-02-01

    Total ankle replacement is recognized as one of the best procedures to treat painful arthritic ankles. Even though this method can relieve patients from pain and reproduce the physiological functions of the ankle, an improper design can cause an excessive amount of metal debris due to wear, causing toxicity in implant recipient. This paper develops a contact model to treat the interaction of tibia and talus implants in an ankle joint. The contact model describes the interaction of implant rough surfaces including both elastic and plastic deformations. In the model, the tibia and the talus surfaces are viewed as macroscopically conforming cylinders or conforming multi-cylinders containing micrometre-scale roughness. The derived equations relate contact force on the implant and the minimum mean surface separation of the rough surfaces. The force is expressed as a statistical integral function of asperity heights over the possible region of interaction of the roughness of the tibia and the talus implant surfaces. A closed-form approximate equation relating contact force and minimum separation is used to obtain energy loss per cycle in a load-unload sequence applied to the implant. In this way implant surface statistics are related to energy loss in the implant that is responsible for internal void formation and subsequent wear and its harmful toxicity to the implant recipient.

  19. Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry

    Directory of Open Access Journals (Sweden)

    Grus Franz-H

    2004-03-01

    Full Text Available Abstract Background The new Ocular Dynamic Contour Tonometer (DCT, investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland allows simultaneous recording of intraocular pressure (IOP and ocular pulse amplitude (OPA. It was the aim of this study to compare the IOP results of this new device with Goldmann tonometry. Furthermore, IOP and OPA measured with the new slitlamp-mounted DCT were compared to the IOP and OPA measured with the hand-held SmartLens®, a gonioscopic contact lens tonometer (ODC Ophthalmic Development Company AG, Switzerland. Methods Nineteen healthy subjects were included in this study. IOP was determined by three consecutive measurements with each of the DCT, SmartLens®, and Goldmann tonometer. Furthermore, OPA was measured three times consecutively by DCT and SmartLens®. Results No difference (P = 0.09 was found between the IOP values by means of DCT (mean: 16.6 mm Hg, median: 15.33 mm Hg, SD: +/- 4.04 mm Hg and Goldmann tonometry (mean: 16.17 mm Hg, median: 15.33 mm Hg, SD: +/- 4.03 mm Hg. The IOP values of SmartLens® (mean: 20.25 mm Hg, median: 19.00 mm Hg, SD: +/- 4.96 mm Hg were significantly higher (P = 0.0008 both from Goldmann tonometry and DCT. The OPA values of the DCT (mean: 3.08 mm Hg, SD: +/- 0.92 mm Hg were significantly lower (P = 0.0003 than those obtained by SmartLens® (mean: 3.92 mm Hg, SD: +/- 0.83 mm Hg. Conclusions DCT was equivalent to Goldmann applanation tonometry in measurement of IOP in a small group of normal subjects. In contrast, SmartLens® (contact lens tonometry gave IOP readings that were significantly higher compared with Goldmann applanation tonometer readings. Both devices, DCT and SmartLens® provide the measurement of OPA which could be helpful e.g. for the management of glaucoma.

  20. Adhesion of Pseudomonas aeruginosa to contact lenses after exposure to multi-purpose lens care solutions

    NARCIS (Netherlands)

    Bruinsma, GM; Van der Mei, HC; Busscher, HJ; de Vries, Jacob

    2001-01-01

    Elemental surface compositions of contact lenses were measured after exposure to different lens care solutions (LCS) using X-ray photoelectron spectroscopy and were related to adhesion and detachment of Pseudomonas aeruginosa. Etafilcon A and polymacon contact lenses, prior to and after exposure to

  1. [Multifocal phakic intraocular lens implant to correct presbyopia].

    Science.gov (United States)

    Baikoff, G; Matach, G; Fontaine, A; Ferraz, C; Spera, C

    2005-03-01

    Presbyopic surgery is considered as the new frontier in refractive surgery. Different solutions are proposed: myopization of one eye, insertion of an accommodative crystalline lens, scleral surgery, the effects of which are still unknown, and finally multifocal phakic implants. We therefore decided to undertake a prospective study under the Huriet law to determine its efficacy and specify the conditions required for an anterior chamber multifocal phakic implant. Fifty-five eyes of 33 patients received an anterior chamber foldable multifocal phakic implant. Twenty-one females and 12 males underwent surgery. Initial refraction was between -5D and +5D. The implant's single addition was +2.50. Recuperating a distant uncorrected visual acuity of 0.6 or better and near uncorrected vision of Parinaud 3 or better can be considered a very good postoperative result. Average follow-up was 42.6+/-18 weeks. Mean postoperative refraction was -0.12+/-0.51 D. Mean postoperative uncorrected visual acuity was 0.78+/-0.20. Postoperative uncorrected visual acuity was Parinaud 2.3+/-0.6. Eighty-four percent of eyes operated on recuperated 0.6 or better without correction and Parinaud 3 or better without correction. Lenses in four eyes were explanted for different reasons, essentially optical, and no severe anatomical complications were observed. Placing an anterior chamber multifocal phakic implant to correct presbyopia is an effective technique with good predictability and has the advantage of being reversible in case of intolerance, optical parasite effects or undesired complications. Considering the particularity of this surgery, it is imperative to respect very strict inclusion criteria: anterior chamber depth equal to or above 3.1 mm, open angle, endothelial cell count equal to or above 2000 cells/mm2, absence of an incipient cataract or the slightest evidence of macular alteration.

  2. Retreatments after multifocal intraocular lens implantation: an analysis

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2016-03-01

    Full Text Available Kjell Gunnar Gundersen,1 Sarah Makari,2 Steffen Ostenstad,1 Rick Potvin2 1Ifocus Eye Clinic, Haugesund, Norway; 2Science in Vision, Akron, NY, USA Purpose: To determine the incidence and etiology of required retreatment after multifocal intraocular lens (IOL implantation and to evaluate the methods and clinical outcomes of retreatment.Patients and methods: A retrospective chart review of 416 eyes of 209 patients from one site that underwent uncomplicated cataract surgery with multifocal IOL implantation. Biometry, the IOL, and refractive data were recorded after the original implantation, with the same data recorded after retreatment. Comments related to vision were obtained both before and after retreatment for retreated patients.Results: The multifocal retreatment rate was 10.8% (45/416 eyes. The eyes that required retreatment had significantly higher residual refractive astigmatism compared with those who did not require retreatment (1.21±0.51 D vs 0.51±0.39 D, P<0.01. The retreatment rate for the two most commonly implanted primary IOLs, blended bifocal (10.5%, 16/152 and bilateral trifocal (6.9%, 14/202 IOLs, was not statistically significantly different (P=0.12. In those requiring retreatment, refractive-related complaints were most common. Retreatment with refractive corneal surgery, in 11% of the eyes, and piggyback IOLs, in 89% of the eyes, was similarly successful, improving patient complaints 78% of the time.Conclusion: Complaints related to ametropia were the main reasons for retreatment. Residual astigmatism appears to be an important determinant of retreatment rate after multifocal IOL implantation. Retreatment can improve symptoms for a high percentage of patients; a piggyback IOL is a viable retreatment option. Keywords: piggyback IOL, Sulcoflex, toric, STAAR, symptoms, astigmatism

  3. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    César Albarrán-Diego

    2017-11-01

    Full Text Available AIM: To evaluate the clinical utility of automated refraction (AR and keratometry (KR compared with subjective or manifest refraction (MR after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH refractive multifocal intraocular lens (IOL. METHODS: Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS: Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION: We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  4. Results of Posterior Chamber Lens Implantation for Correction of Myopia

    Directory of Open Access Journals (Sweden)

    Pınar Sorgun Evcili

    2012-10-01

    Full Text Available Pur po se: To evaluate the results of posterior chamber phakic intraocular lens implantation in myopic patients. Ma te ri al and Met hod: Posterior chamber phakic intraocular lens (STAAR ICL implantation was performed in 58 eyes of 33 patients with mean spherical equivalent of -13.12±5.31 diopters (D (-2.5 - -24.75 D between August 2007 and October 2010 at Dr. Lütfi Kırdar Kartal Training and Research Hospital, Second Eye Clinic. The mean age of the patients was 32.84 ± 9.95 years (18-55 years - 24 (72.7% were male and 9 (27.3% were female. The study was designed as prospective case series. The patients were evaluated regarding visual acuity, refraction, endothelial cell count, and complications in postoperative period. Re sults: The mean follow-up time was 21.5±4.9 (12-24 months months. The mean spherical equivalent was -1.29±1.53 D (-5.6 D - +2.60 D at the last postoperative follow-up visit. Visual acuity was better or equal to preoperative best-corrected value in 42 (72.4% of eyes at the last follow-up visit postoperatively. Mean spherical equivalent was regressed to -1.13±1.59D at 1-month and -1.39±1.53D at 24-month postoperative follow-up visit. Pupillary-block glaucoma in 1 eye (1.7%, anterior subcapsular opacification not affecting the vision in 4 eyes, and retinal detachment in 1 eye were detected at follow-up visits. Dis cus si on: ICL implantation was observed to be an effective and safe method for correction of myopia in two-year follow-up. As possible retinal complications may develop, the patients must be followed carefully during the preoperative and postoperative period. (Turk J Ophthalmol 2012; 42: 349-54

  5. The potential pathogenicity of chlorhexidine-sensitive Acanthamoeba strains isolated from contact lens cases from asymptomatic individuals in Tenerife, Canary Islands, Spain.

    Science.gov (United States)

    Martín-Navarro, Carmen M; Lorenzo-Morales, Jacob; Cabrera-Serra, M Gabriela; Rancel, Fernando; Coronado-Alvarez, Nieves M; Piñero, José E; Valladares, Basilio

    2008-11-01

    Pathogenic strains of the genus Acanthamoeba are causative agents of a serious sight-threatening infection of the eye known as Acanthamoeba keratitis. The prevalence of this infection has risen in the past 20 years, mainly due to the increase in number of contact lens wearers. In this study, the prevalence of Acanthamoeba in a risk group constituted by asymptomatic contact lens wearers from Tenerife, Canary Islands, Spain, was evaluated. Contact lenses and contact lens cases were analysed for the presence of Acanthamoeba isolates. The isolates' genotypes were also determined after rDNA sequencing. The pathogenic potential of the isolated strains was subsequently established using previously described molecular and biochemical assays, which allowed the selection of three strains with high pathogenic potential. Furthermore, the sensitivity of these isolates against two standard drugs, ciprofloxacin and chlorhexidine, was analysed. As the three selected strains were sensitive to chlorhexidine, its activity and IC(50) were evaluated. Chlorhexidine was found to be active against these strains and the obtained IC(50) values were compared to the concentrations of this drug present in contact lens maintenance solutions. It was observed that the measured IC(50) was higher than the concentration found in these maintenance solutions. Therefore, the ineffectiveness of chlorhexidine-containing contact lens maintenance solutions against potentially pathogenic strains of Acanthamoeba is demonstrated in this study.

  6. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    OpenAIRE

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    AIM:To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation.METHODS:Non-comparative retrospective observational case series. Participants:30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Opht...

  7. Carbachol as miotic agent in intra-ocular lens implant surgery

    Directory of Open Access Journals (Sweden)

    Agarwal Jitendra

    1988-01-01

    Full Text Available The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens im-plant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:

  8. Design and application of ion-implanted polySi passivating contacts for interdigitated back contact c-Si solar cells

    International Nuclear Information System (INIS)

    Yang, Guangtao; Ingenito, Andrea; Hameren, Nienke van; Isabella, Olindo; Zeman, Miro

    2016-01-01

    Ion-implanted passivating contacts based on poly-crystalline silicon (polySi) are enabled by tunneling oxide, optimized, and used to fabricate interdigitated back contact (IBC) solar cells. Both n-type (phosphorous doped) and p-type (boron doped) passivating contacts are fabricated by ion-implantation of intrinsic polySi layers deposited via low-pressure chemical vapor deposition and subsequently annealed. The impact of doping profile on the passivation quality of the polySi doped contacts is studied for both polarities. It was found that an excellent surface passivation could be obtained by confining as much as possible the implanted-and-activated dopants within the polySi layers. The doping profile in the polySi was controlled by modifying the polySi thickness, the energy and dose of ion-implantation, and the temperature and time of annealing. An implied open-circuit voltage of 721 mV for n-type and 692 mV for p-type passivating contacts was achieved. Besides the high passivating quality, the developed passivating contacts exhibit reasonable high conductivity (R sh n-type  = 95 Ω/□ and R sh p-type  = 120 Ω/□). An efficiency of 19.2% (V oc  = 673 mV, J sc  = 38.0 mA/cm 2 , FF = 75.2%, and pseudo-FF = 83.2%) was achieved on a front-textured IBC solar cell with polySi passivating contacts as both back surface field and emitter. By improving the front-side passivation, a V OC of 696 mV was also measured

  9. Surgical effect of traumatic lens dislocation with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Xiao-Dan Zhang

    2014-10-01

    Full Text Available AIM: To retrospectively evaluate the effect of lens extraction combined with vitrectomy to treat traumatic lens dislocation with secondary glaucoma.METHODS:Thirty-one eyes(31 casesof lens dislocation caused by blunt trauma with secondary glaucoma were treated respectively with cataract extraction combined with anterior vitrectomy, trabeculectomy and intraocular lens implantation. The visual acuity and pressure were observed 1wk, 1 and 3mo after operative. RESULTS:Thirty-one eyes were all complete the operation successfully, and 6 eyes were given combined trabeculectomy, 9 eyes were implanted anterior chamber intraocular lens implantation(IOLand 15 eyes were given posterior chamber suture fixation. Sixteen eyes were implanted in one-stage operation, while 8 eyes were implanted in two-stage operation. All intraocular pressure(IOPwere controlled to the normal level after operation and 23 eyes had visual acuity of more than 0.3.CONCLUSION:Lens extraction combined with vitrectomy is an effective method for treatment of lens dislocation with secondary glaucoma. In order to control the IOP and get well visual function, we should choose IOL implantation or trabeculectomy according to the patient's condition.

  10. Acanthamoeba encystment: multifactorial effects of buffers, biocides, and demulcents present in contact lens care solutions

    Directory of Open Access Journals (Sweden)

    Kovacs CJ

    2015-10-01

    Full Text Available Christopher J Kovacs, Shawn C Lynch, Marjorie J Rah, Kimberly A Millard, Timothy W Morris Bausch & Lomb Incorporated, Rochester, NY, USA Purpose: To determine whether agents which are purportedly capable of inducing encystment of Acanthamoeba can recapitulate the signal when tested in differing formulations. Methods: In accordance with the International Standard ISO 19045, Acanthamoeba castellanii ATCC 50370 trophozoites were cultured in antibiotic-free axenic medium, treated with test solutions, and encystment rates plus viability were measured via bright field and fluorescent microscopy. Test solutions included phosphate-buffered saline (PBS, borate-buffered saline, biguanide- and hydrogen peroxide (H2O2-based biocides, propylene glycol (PG and povidone (POV ophthalmic demulcents, and one-step H2O2-based contact lens disinfection systems. Results: Only PBS solutions with 0.25 ppm polyaminopropyl biguanide (PAPB and increasing concentrations of PG and POV stimulated A. castellanii encystment in a dose-dependent manner, whereas PBS solutions containing 3% H2O2 and increasing concentrations of PG and POV did not stimulate encystment. Borate-buffered saline and PBS/citrate solutions containing PG also did not stimulate encystment. In addition, no encystment was observed after 24 hours, 7 days, or 14 days of exposures of trophozoites to one-step H2O2 contact lens disinfection products or related solutions. Conclusion: The lack of any encystment observed when trophozoites were treated with existing or new one-step H2O2 contact lens care products, as well as when trophozoites were exposed to various related test solutions, confirms that Acanthamoeba encystment is a complex process which depends upon simultaneous contributions of multiple factors including buffers, biocides, and demulcents. Keywords: propylene glycol, contact lens care system, hydrogen peroxide disinfecting solution

  11. Potential Bone to Implant Contact Area of Short Versus Standard Implants: An In Vitro Micro-Computed Tomography Analysis.

    Science.gov (United States)

    Quaranta, Alessandro; DʼIsidoro, Orlando; Bambini, Fabrizio; Putignano, Angelo

    2016-02-01

    To compare the available potential bone-implant contact (PBIC) area of standard and short dental implants by micro-computed tomography (μCT) assessment. Three short implants with different diameters (4.5 × 6 mm, 4.1 × 7 mm, and 4.1 × 6 mm) and 2 standard implants (3.5 × 10 mm and 3.3 × 9 mm) with diverse design and surface features were scanned with μCT. Cross-sectional images were obtained. Image data were manually processed to find the plane that corresponds to the most coronal contact point between the crestal bone and implant. The available PBIC was calculated for each sample. Later on, the cross-sectional slices were processed by a 3-dimensional (3D) software, and 3D images of each sample were used for descriptive analysis and display the microtopography and macrotopography. The wide-diameter short implant (4.5 × 6 mm) showed the higher PBIC (210.89 mm) value followed by the standard (178.07 mm and 185.37 mm) and short implants (130.70 mm and 110.70 mm). Wide-diameter short implants show a surface area comparable with standard implants. Micro-CT analysis is a promising technique to evaluate surface area in dental implants with different macrodesign, microdesign, and surface features.

  12. Analysis of incidence and related factors on effusion of anterior chamber after phacoemulsification combined with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Bing-Bing Zhao

    2018-02-01

    Full Text Available AIM: To investigate the incidence and related factors on effusion of anterior chamber(ACafter phacoemulsification(PEcombined with intraocular lens(IOLimplantation. METHODS: Totally 359 cases of cataract(375 eyesunderwent PE combined with IOL implantation were collected in our hospital. The incidence of AC exudation after operation and related factors were analyzed by single factor and multiple logistic regression analysis. RESULTS: The group was included in 359 cases(375 eyes. The incidence of postoperative AC exudation in the study group was 5.9%(22/375. The preoperative intraocular pressure(IOP, visual acuity before and after surgery, nuclear grades, posterior capsular rupture(PCRrate and ultrasonic accumulated energy complex parameter(AECPof the study group showed statistically significant difference compared with the control group(all P21mmHg, intraoperative pupil diameter 7.25(%×min, the lens nucleus grade ≥ IV were risk factors of AC exudation after PE combined with IOL implantation in patients with cataract(all P21mmHg, ultrasound AECP >7.25 were independent risk factors of AC exudation after PE combined with IOL implantation in patients with cataract(all PCONCLUSION: High myopia, glaucoma, uveitis, the lens nucleus grade ≥ IV, the incidence of intraoperative PCR, preoperative IOP>21mmHg, ultrasonic AECP>7.25 are independent risk factors of AC exudation after PE combined with IOL implantation in patients with cataract, with such risk factors in patients with cataract should be paid closely attention and timely diagnosis and treatment in clinic.

  13. Conjunctival impression cytology versus routine tear function tests for dry eye evaluation in contact lens wearers.

    Science.gov (United States)

    Kumar, Prachi; Bhargava, Rahul; Arora, Yogesh C; Kaushal, Sidharth; Kumar, Manjushri

    2015-01-01

    Prolonged contact lens wear is often accompanied by dryness of the eyes. The aim of this study was to compare conjunctival impression cytology (CIC) and tear film tests such as tear film break up time (TBUT) and Schirmer test for dry eye evaluation in contact lens wearers and measure their correlation with dry eye symptoms. A case control study was done at three referral eye centers. The eyes of 230 contact lens users were compared to 250 eyes of age- and sex-matched controls. Participants were recruited based on their response to a questionnaire of dry eye symptoms, (Dry Eye Scoring System, DESS(©)) and measurements of TBUT, Schirmer test, and CIC was done. A correlation analysis between symptom severity and tear film tests was performed. Pearson's coefficient, R(2) > 0.5 was considered significant. As compared to controls (r (2) = 0.010), Nelson grade correlated significantly with dry eye symptoms (r (2) = 0.765), among cases. However, there was moderate correlation between dry eye symptoms, Schirmer test, and TBUT (r (2) = 0.557 and 0.530, respectively) among cases and a weak correlation among controls (r (2) = 0.130 and 0.054, respectively). The sensitivity of TBUT was 86.4%, specificity was 82.4%, positive likelihood ratio (LR) was 4.50 [95% confidence interval (CI) 3.46-5.85)], and negative LR was 0.09. The sensitivity of the Schirmer test was 48.2%, specificity 88%, LR 2.12 (95% CI 1.48-2.96), and negative LR 0.83. CIC correlates better than Schirmer and TBUT with dry eye symptoms. It may be the most appropriate test for dry-eye evaluation in contact lens wearers.

  14. The Disinfecting Potential of Contact Lens Soutions used by Sultan Qaboos University Students

    Science.gov (United States)

    Nzeako, B. C.; Al-Sumri, Sara H.

    2011-01-01

    Objectives: This study aimed to determine the disinfecting potential of some contact lens solutions used by some university students in Oman. Methods: This work was carried out from January to June 2010 in the Department of Microbiology & Immunology, College of Medicine and Health Sciences, Sultan Qaboos University, Oman. Fifty disinfecting solutions, in which contact lenses were disinfected according to the manufacturers’ instructions, were collected from the students and plated on various microbiological culture media. Bacterial isolates were identified by API-20E, API-20NE and Phoenix automated systems while fungi were identified by their cultural characteristics and biochemistry. Results: From 98 isolates, Pseudomonas aeruginosa was 23.5%; Penicillium, 13%; Candida species, 9.2%; coagulase negative staphylococci, 9.2%; Serratia marcescens, 6.1%; Bacillus, 5.1%; Aspergillus flavus, 5.1%; Serratia liquefaciens, Pseudomonas fluorescens, Enterobacter cloacae and Aspergillus niger, 4.1% each; Chryseomonas luteola and Chryseomonas indologenes, 3.1% each; Stenotrophomonas maltophilia, Serratia odorifera, 2.0% each; Enterobacter aerogenes and Klebsiella pneumoniae, 1% each. Most isolates (65%) came from polyhexanide containing solutions. Conclusion: Contact lens disinfecting solutions with the same formulations, but manufactured by different companies, possessed different disinfecting potentials. PMID:21969898

  15. Efficacy of contact lens disinfecting solutions against Staphylococcus aureus and Pseudomonas aeruginosa.

    Science.gov (United States)

    Manuj, Kapur; Gunderson, Charlise; Troupe, John; Huber, Mary E

    2006-07-01

    To evaluate the disinfection properties of multipurpose contact lens disinfection solutions, based on the International Organization for Standardization (ISO) 14729 guidelines. ReNu with MoistureLoc Multi-Purpose Solution, OPTI-FREE Express with Aldox Multi-Purpose Solution, Betadine 5% sterile ophthalmic preparation solution (povidone iodine), and 0.9% normal saline solution were inoculated with strains of Staphylococcus aureus and Pseudomonas aeruginosa. Surviving bacteria were quantified at specified times. ReNu with MoistureLoc, OPTI-FREE Express, and 5% ophthalmic povidone iodine were effective in achieving a 5-log reduction in bacterial count. Additionally, all three products maintained their effectivity at 72 hours. However, ReNu with MoistureLoc and povidone iodine resulted in the greatest reduction in bacterial colonization. ReNu with MoistureLoc, OPTI-FREE Express, and 5% ophthalmic povidone iodine meet the ISO 14729 guidelines for standalone contact lens solutions. However, ReNu with MoistureLoc and 5% ophthalmic povidone iodine are most efficient in reducing and maintaining low bacterial count for a period of 72 hours.

  16. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children.

    Science.gov (United States)

    Das, Pranab; Ram, Jagat; Brar, Gagandeep Singh; Dogra, Mangat R

    2009-01-01

    To evaluate the outcome of intraocular lens (IOL) implantation using capsular tension ring (CTR) in subluxated crystalline or cataractous lenses in children. Tertiary care setting. We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90 degrees up to 210 degrees after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior capsular opacification (PCO). Age of the patient ranged between five to 15 years. Out of 18 eyes, seven had traumatic and 11 had spontaneous subluxation of crystalline or cataractous lens. Phacoemulsification was successfully performed with CTR implantation in the capsular bag. Intraoperative zonular dialysis occurred in two eyes. Anterior vitrectomy was performed in six eyes to manage vitreous prolapse. IOL implanted was polymethyl methacrylate (PMMA) in eight eyes, hydrophobic acrylic in seven and hydrophilic acrylic in three. Follow-up ranged from 24 months to 72 months. Sixteen eyes had a best corrected visual acuity of 20/40 or better. Nine eyes developed significant PCO and were managed with Neodymium Yttrium Aluminum Garnet (Nd:YAG) laser posterior capsulotomy. One eye with acrylic IOL in the capsular bag had IOL dislocation after two years which was managed with vitrectomy and secondary trans-scleral fixation of IOL. Phacoaspiration with CTR implantation makes capsular bag IOL fixation possible in most of the eyes with subluxated crystalline or cataractous lenses. PCO still remains a challenge in children with successful phacoaspiration with CTR implantation.

  17. Simultaneous and sequential implantation of intacs and verisyse phakic intraocular lens for refractive improvement in keratectasia.

    Science.gov (United States)

    Moshirfar, Majid; Fenzl, Carlton R; Meyer, Jay J; Neuffer, Marcus C; Espandar, Ladan; Mifflin, Mark D

    2011-02-01

    To evaluate the safety, efficacy, and visual outcomes of simultaneous and sequential implantation of Intacs (Addition Technology, Inc, Sunnyvale, CA) and Verisyse phakic intraocular lens (AMO, Santa Ana, CA) in selected cases of ectatic corneal disease. John A. Moran Eye Center, University of Utah, UT. Prospective data were collected from 19 eyes of 12 patients (5 eyes, post-laser in situ keratomileusis ectasia and 14 eyes, keratoconus). Intacs segments were implanted followed by insertion of a phakic Verisyse lens at the same session (12 eyes) in the simultaneous group or several months later (7 eyes) in the sequential group. The uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), and manifest refraction were recorded at each visit. No intraoperative or postoperative complications were observed. At the last follow-up (19 ± 6 months), in the simultaneous group, mean spherical error was -0.79 ± 1.0 diopter (D) (range, -2.0 to +1.50 D) and cylindrical error +2.06 ± 1.21 D (range, +0.5 to +3.75 D). In the sequential group, at the last follow-up, at 36 ± 21 months, the mean spherical error was -1.64 ± 1.31 D (range, -3.25 to +1.0 D) and cylindrical error +2.07 ± 1.03 D (range, +0.75 to +3.25 D). There were no significant differences in mean uncorrected visual acuity or BSCVA between the 2 groups preoperatively or postoperatively. No eye lost lines of preoperative BSCVA. Combined insertion of Intacs and Verisyse was safe and effective in all cases. The outcomes of the simultaneous implantation of the Intacs and Verisyse lens in 1 surgery were similar to the results achieved with sequential implantation using 2 surgeries.

  18. A histopathological study of bulbar conjunctival flaps occurring in 2 contact lens wearers.

    Science.gov (United States)

    Markoulli, Maria; Francis, Ian C; Yong, Jim; Jalbert, Isabelle; Carnt, Nicole; Cole, Nerida; Papas, Eric

    2011-09-01

    To study the histopathology of paralimbal bulbar conjunctival flaps occurring secondary to soft contact lens wear. Slit-lamp biomicroscopy using sodium fluorescein, cobalt blue light, and a Wratten filter was used to observe the presence, location, and dimensions of bulbar conjunctival flaps presenting in a cohort of contact lens wearers. Two subjects who exhibited such flaps agreed to undergo conjunctival biopsy. Tissue samples, obtained from the region of the flap, and an adjacent unaffected area were processed by standard histopathological methods. In the first subject, analysis of the flap tissue showed even collagen distribution and overall normal histology. The flap of the second subject displayed a mild focal increase in collagen and mild degeneration of collagen, but no increase in elastic tissue. Conjunctival epithelium was normal in both cases. In these 2 subjects, conjunctival flap tissue either was normal or showed only minimal abnormality. There is insufficient evidence for significant pathological change on the time scale of this study.

  19. Clinical observation of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract in the sight restoration project

    Directory of Open Access Journals (Sweden)

    Xiao-Jian Cheng

    2014-04-01

    Full Text Available AIM: To analyze the clinical effects of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract.METHODS:Totally 642 cases 676 eyes of cataract were treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Complication during and after operations and postoperative visual acuity was observed.RESULTS:Visual acuity of 670 eyes was ≥0.05 and off-blindness rate was 99.11%, and there was 627 eyes ≥0.3 and the off-disability rate was 92.75% after 1mo. Rupture of posterior capsule during surgery occurred in 24 eyes. Fifty-four eyes were corneal edema, and anterior chamber exudation were 26 eyes, and 23 eyes were hypertension after operation. CONCLUSION: There are a little complications during and after operation for cataract treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Patients have good recovery after operation. This operation does not need high-standard equipments and is suitable in the sight restoration project.

  20. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children

    OpenAIRE

    Das, Pranab; Ram, Jagat; Brar, Gagandeep Singh; Dogra, Mangat R

    2009-01-01

    Purpose : To evaluate the outcome of intraocular lens (IOL) implantation using capsular tension ring (CTR) in subluxated crystalline or cataractous lenses in children. Setting : Tertiary care setting Materials and Methods : We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90° up to 210° after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior ...

  1. A Novel Anti-Spoofing Solution for Iris Recognition Toward Cosmetic Contact Lens Attack Using Spectral ICA Analysis.

    Science.gov (United States)

    Hsieh, Sheng-Hsun; Li, Yung-Hui; Wang, Wei; Tien, Chung-Hao

    2018-03-06

    In this study, we maneuvered a dual-band spectral imaging system to capture an iridal image from a cosmetic-contact-lens-wearing subject. By using the independent component analysis to separate individual spectral primitives, we successfully distinguished the natural iris texture from the cosmetic contact lens (CCL) pattern, and restored the genuine iris patterns from the CCL-polluted image. Based on a database containing 200 test image pairs from 20 CCL-wearing subjects as the proof of concept, the recognition accuracy (False Rejection Rate: FRR) was improved from FRR = 10.52% to FRR = 0.57% with the proposed ICA anti-spoofing scheme.

  2. Refractive Results: Safety and Efficacy of Secondary Piggyback Sensar™ AR40 Intraocular Lens Implantation to Correct Pseudophakic Refractive Error

    Directory of Open Access Journals (Sweden)

    Alahmady Hamad Alsmman Hassan

    2016-01-01

    Full Text Available In this study we evaluate the visual outcomes, safety, efficacy, and stability of implanting of second sulcus intraocular lens (IOL to correct unsatisfied ametropic patients after phacoemulsification. Methods. Retrospective study of 15 eyes (15 patients underwent secondary intraocular lens implanted into the ciliary sulcus. The IOL used was a Sensar IOL three-piece foldable hydrophobic acrylic IOL. The first IOL in all patients was acrylic intrabagal IOL implanted in uncomplicated phacoemulsification surgery. Results. Fifteen eyes (15 patients were involved in this study. Preoperatively, mean log⁡MAR UDVA and CDVA were 0.88 ± 0.22 and 0.19 ± 0.13, respectively, with a mean follow-up of 28 months (range: 24 to 36 months. At the end of the follow-up, all eyes achieved log⁡MAR UDVA of 0.20 ± 0.12 with postoperative refraction ranging from 0.00 to −0.50 D of attempted emmetropia. Conclusions. Implantation of the second sulcus SensarAR40 IOL was found to be safe, easy, and simple technique for management of ametropia following uncomplicated phacoemulsification.

  3. The effect of contact lens usage on corneal biomechanical parameters in myopic patients.

    Science.gov (United States)

    Cankaya, Ali B; Beyazyildiz, Emrullah; Ileri, Dilek; Ozturk, Faruk

    2012-07-01

    To determine and compare the corneal biomechanical properties in myopic patients who use contact lenses and those who do not use contact lenses. The study consisted of 56 myopic patients who used contact lenses (study group) and 123 myopic patients who did not use contact lenses (control group). Intraocular pressure (IOP) was measured with an ocular response analyzer (ORA) and a Goldmann applanation tonometer. Central corneal thickness was measured with an ultrasonic pachymeter. Axial length and anterior chamber depth measurements were acquired with contact ultrasound A-scan biometry. The differences in ORA parameters between study and control group participants were analyzed. The mean corneal hysteresis in study and control groups was 10.1 ± 1.6 mm Hg (6.5-15.9 mm Hg) and 9.7 ± 1.5 mm Hg (6.3-14.2 mm Hg), respectively (P = 0.16). The mean corneal resistance factor was 10.4 ± 1.9 mm Hg (4.6-15.5 mm Hg) in the study group compared with 9.6 ± 1.9 mm Hg (5.1-15.0 mm Hg) in the control group. The difference for corneal resistance factor was statistically significant (P = 0.014). There was no significant difference in corneal-compensated IOP (P = 0.24). Mean Goldmann-correlated IOP was significantly higher in the study group than in control subjects (15.8 ± 3.2 vs. 14.7 ± 3.7 mm Hg) (P = 0.044). None of the corneal biomechanical parameters was significantly correlated to duration of contact lens usage in the study group. Our results suggest that ORA-generated parameters may be different in subjects with and without contact lens usage. Further longitudinal studies need to be performed to establish the relevance of our results.

  4. Development of an accommodating intra-ocular lens - In vitro prevention of re-growth of pig and rabbit lens capsule epithelial cells

    NARCIS (Netherlands)

    van Kooten, Theo G.; Koopmans, Steven; Terwee, Thom; Norrby, Sverker; Hooymans, J. M. M.; Busscher, Henk J.

    2006-01-01

    Cataract surgery is routinely performed to replace the clouded lens by a rigid polymeric intra-ocular lens unable to accommodate. By implanting a silicone gel into an intact capsular bag the accommodating properties of the natural lens can be maintained or enhanced. The implantation success of

  5. Clinical research of phacoemulsification with posterior chamber intraocular lens implantation for glaucoma with different goniosynechia ranges

    Directory of Open Access Journals (Sweden)

    Qing-Yu Li

    2016-02-01

    Full Text Available AIM:To study the effect of phacoemulsification with posterior chamber intraocular lens implantation to treat glaucoma with different angle-closure range, which may provide a better way to treat the angle-closure glaucoma.METHODS:There were 47 cases(54 eyeswith angle-closure glaucoma, and all of them underwent phacoemulsification and posterior chamber intraocular lens implantation. According to the range of goniosynechia, these patients were divided into three groups:the eyes with the range of goniosynechia≤1/2 were group A(13 eyes; the eyes with 1/23/4 were group C(23 eyes. We observed the status of anterior chamber angle and the intraocular pressure(IOPof the three groups at 2wk after operations. RESULTS:Compared to the preoperative condition, the IOP of the three groups at 2wk after operations decreased significantly. The IOP reductions of group B and C were more significant than that of group A, and the differences were significant(PPP3/4 appeared in group B; in group C, there were 5 eyes with goniosynechia>3/4, 1 eye with disappeared anterior chamber, 3 eyes with corneal edema, 1 eye with choroidal hemorrhage. The differences of postoperative complication rate among the three groups was statistically significant(PPCONCLUSION:For patients with angle closure glaucoma who have mild to moderate goniosynechia, phacoemulsification with posterior chamber intraocular lens implantation is an effective way. After operations, their closed anterior angle reopened. But to the patients with severe adhesions, there are more complications after operations, especially the glaucoma may reoccur.

  6. Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

    Science.gov (United States)

    Kazemi, S; Wirostko, W J; Sinha, S; Mieler, W F; Koenig, S B; Sheth, B P

    2000-01-01

    To review our experience with combined pars plana lensectomy-vitrectomy and open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for managing subluxated crystalline lenses. Retrospective review of 36 consecutive eyes (28 patients), all of which had subluxated crystalline lenses, managed by pars plana lensectomy-vitrectomy with insertion of an open-loop flexible AC IOL. The study was performed at the Medical College of Wisconsin, Milwaukee, over an 8-year period. An average preoperative visual acuity of 20/163 (range, 20/25 to hand motions) improved to 20/36 (range, 20/20 to 4/200) with surgery after a mean follow-up of 14 months (range, 1 to 59 months) (P IOL implantation appears to be an excellent technique for managing subluxated crystalline lenses. It is associated with a significant improvement in visual acuity (P subluxated lens through a limbal wound. Additionally, use of an AC IOL offers a simplified alternative to placement of a ciliary sulcus sutured posterior chamber intraocular lens (PC IOL).

  7. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma.

    Science.gov (United States)

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. Non-comparative retrospective observational case series. 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and endophthalmitis. To take early treatment of traumatic lens

  8. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children

    Directory of Open Access Journals (Sweden)

    Das Pranab

    2009-01-01

    Full Text Available Purpose : To evaluate the outcome of intraocular lens (IOL implantation using capsular tension ring (CTR in subluxated crystalline or cataractous lenses in children. Setting : Tertiary care setting Materials and Methods : We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90° up to 210° after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior capsular opacification (PCO. Results : Age of the patient ranged between five to 15 years. Out of 18 eyes, seven had traumatic and 11 had spontaneous subluxation of crystalline or cataractous lens. Phacoemulsification was successfully performed with CTR implantation in the capsular bag. Intraoperative zonular dialysis occurred in two eyes. Anterior vitrectomy was performed in six eyes to manage vitreous prolapse. IOL implanted was polymethyl methacrylate (PMMA in eight eyes, hydrophobic acrylic in seven and hydrophilic acrylic in three. Follow-up ranged from 24 months to 72 months. Sixteen eyes had a best corrected visual acuity of 20/40 or better. Nine eyes developed significant PCO and were managed with Neodymium Yttrium Aluminum Garnet (Nd:YAG laser posterior capsulotomy. One eye with acrylic IOL in the capsular bag had IOL dislocation after two years which was managed with vitrectomy and secondary trans-scleral fixation of IOL. Conclusions : Phacoaspiration with CTR implantation makes capsular bag IOL fixation possible in most of the eyes with subluxated crystalline or cataractous lenses. PCO still remains a challenge in children with successful phacoaspiration with CTR implantation

  9. Scharioth Macula Lens: A new intraocular implant for low-vision patients with stabilized maculopathy- first experience.

    Science.gov (United States)

    Nekolova, Jana; Rozsival, Pavel; Sin, Martin; Jiraskova, Nada

    2017-06-01

    To present the initial results of Scharioth Macula Lens (SML) implantation. The SML is a new add-on intraocular lens designed to increase uncorrected near visual acuity (UCVA) in patients with stabilized maculopathy. Eight patients were included in the study. All met the indication criteria before SML implantation. An SML was implanted in the better seeing eye. Near and distance visual acuity were tested. Possible complications and patient complaints were recorded and patients were asked about their quality of vision after SML implantation. The examination was carried out on day 1, 1 week, 1, 3 and 6 months after surgery. Six-month-results are presented. Apart from one, all patients with the SML had good near visual acuity at a recommended reading distance of 15 cm. Preoperatively, the mean (min-max) near UCVA was J13 (J8-J16), mean distance BCVA was 0.27. Postoperatively, the best results were after 1 month - near UCVA was J2.5 (J1-J7), distance BCVA was 0.26. Three months after surgery, this decreased to J4.5 (J1-J8); distance VA remained 0.25. Six months postoperatively - near vision was J4 (J1-J8) and distance VA was unchanged. Patients reported problems with reading speed and reading distance. Daily exercise improved their reading ability. One patient converted to wet AMD 3 months post-implantation. The SML is a new hope for low-vision patients. It acts as a magnifier in the eye. It is a suitable method for increasing near visual acuity in patients with inactive maculopathy.

  10. On the the Contact Lens Problem: Modeling Rigid and Elastic Beams on Thin Films

    Science.gov (United States)

    Trinh, Philippe; Wilson, Stephen; Stone, Howard

    2011-11-01

    Generally, contact lenses are prescribed by the practitioner to fit each individual patient's eye, but these fitting-philosophies are based on empirical studies and a certain degree of trial-and-error. A badly fitted lens can cause a range of afflictions, which varies from mild dry-eye-discomfort, to more serious corneal diseases. Thus, at this heart of this problem, is the question of how a rigid or elastic plate interacts with the free-surface of a thin viscous film. In this talk, we present several mathematical models for the study of these plate-and-fluid problems. Asymptotic and numerical results are described, and we explain the role of elasticity, surface tension, viscosity, and pressure in determining the equilibrium solutions. Finally, we discuss the implications of our work on the contact lens problem, as well as on other coating processes which involve elastic substrates.

  11. 1/f Fluctuations in ion implanted metal semiconductor contacts

    International Nuclear Information System (INIS)

    Stojanovic, M.; Marjanovic, N.; Radojevic, B.

    1998-01-01

    Ion implanted Metal-Semiconductor contacts is the most widely used structures in electrical devices. Weather complete devices or some parts are of interest, properties of metal-semiconductor junction strongly influence the quality and external characteristic of electronic devices. That is the reason why special attention is paid to the investigation of factor (noise for example) that could influence given junction. Low frequency 1/f fluctuations (noise) are constantly present in metal-semiconductor junction, so measurement of their level as well as the dependence on factors such as temperature must be taken into account in detailed analysis of electrical characteristics of devices such as contact, nuclear detector with surface barrier etc. In this paper we present the results of low frequency noise level measurements on TiN-Ti-Si structures produced by As + ion implantation. (author)

  12. Evaluation of diminished microbial contamination in handling of a novel daily disposable flat pack contact lens.

    Science.gov (United States)

    Nomachi, Miya; Sakanishi, Kotaro; Ichijima, Hideji; Cavanagh, H Dwight

    2013-05-01

    To evaluate the efficacy of a novel daily disposable (DD) flat package in regard to microbial contamination on the anterior and posterior surfaces of a contact lens (CL) during handling of the lens for insertion. Four kinds of commercially available general blister-packed daily disposable contact lenses (DD CLs) as controls and a novel Magic 1-day Menicon Flat Pack as a test lens were used for this in vitro study. Lenses were removed from their packages using fingers coated with fluorescein 3 to 5 μm beads or an approximately 7×10(2) to 2×10(3) colony-forming unit (CFU)/mL Staphylococcus aureus suspension. The transfer of fluorescein beads to the surface of the lenses was then observed by fluorescence microscopy. Microbial contamination on the lenses was observed by light microscopy after a 2-day incubation period; and, the number of colonies isolated from the contaminated lenses was determined after 4 days of incubation. The number of fluorescein beads on the Magic lens was significantly less (p<0.05) than that of the general blister-packed control lenses. Adherence of microbial colonies was observed on both inner and outer surfaces of general blister-packed lenses, whereas no colony formation was found on the inner surface of the Magic lens, and the lowest bacterial adherence was observed for the Magic lens. The data demonstrated that placement of the Magic DD lens onto the eye is accompanied by diminished microbial contamination compared with general blister-packed DD CLs. Eye care professionals; however, should instruct patients to comply with intended use of DD CLs to prevent CL-associated microbial keratitis. In all cases, hand washing is mandated prelens insertion.

  13. Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Vilar C

    2017-08-01

    Full Text Available César Vilar,1,2 Wilson Takashi Hida,1–3 André Lins de Medeiros,1,2 Klayny Rafaella Pereira Magalhães,2 Patrick Frensel de Moraes Tzelikis,1,2 Mario Augusto Pereira Dias Chaves,2,4 Antônio Francisco Pimenta Motta,2,3 Pedro Carlos Carricondo,1–3 Milton Ruiz Alves,3 Walton Nosé5 1Cataract Division, Brasília Ophthalmologic Hospital (HOB, Brasília-DF, Brazil; 2Renato Ambrosio Ophthalmologic Research Center (CEORA, 3Ophthalmology Department, São Paulo University – USP, São Paulo-SP, Brazil; 4Cataract Division, ProVisão, João Pessoa-PB, Brazil; 5Ophthalmology Department, Paulista Medical School – UNIFESP, São Paulo-SP, Brazil Purpose: To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye.Methods: This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA and uncorrected intermediate (60 cm and near (at 40 cm visual acuity; contrast sensitivity (CS and visual defocus curve.Results: Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision.Conclusion: Both lens combinations were able to provide good near, intermediate and distance vision

  14. Diquafosol Ophthalmic Solution Increases Pre- and Postlens Tear Film During Contact Lens Wear in Rabbit Eyes.

    Science.gov (United States)

    Nagahara, Yukiko; Koh, Shizuka; Oshita, Yoshihiro; Nagano, Takashi; Mano, Hidetoshi; Nishida, Kohji; Watanabe, Hitoshi

    2017-11-01

    To investigate the behavior of prelens tear film (PLTF) and postlens tear film (PoLTF) after the instillation of diquafosol using an experimental rabbit model of eyes with contact lens. Cross-sectional, anterior segment optical coherence tomographic images of the inferior midperipheral cornea were obtained at baseline and at 5, 15, 30, 60, 90, and 120 min after the instillation of 3% diquafosol ophthalmic solution in 10 Japanese white rabbits wearing contact lenses. From the obtained images, the areas of the PLTF and PoLTF were calculated. Both artificial tear solution and 0.1% sodium hyaluronate ophthalmic solution were used for comparison. Significant fluid accumulation in both the PLTF and PoLTF was observed after diquafosol instillation, whereas no fluid accumulation was visible after the instillation of artificial tear or sodium hyaluronate. The increase in PLTF area after diquafosol instillation was significantly higher (Pophthalmic solution increases PLTF and PoLTF in rabbit eyes with contact lenses. Diquafosol has potential as a treatment option for contact lens-related dry eye.

  15. Removal of intraocular foreign body in anterior chamber angle with prism contact lens and 23-gauge foreign body forceps.

    Science.gov (United States)

    Huang, Yan-Ming; Yan, Hua; Cai, Jin-Hong; Li, Hai-Bo

    2017-01-01

    To introduce a novel approach in removal of anterior chamber angle foreign body (ACFB) using a prism contact lens and 23-gauge foreign body forceps. Data of 42 eyes of 42 patients who had undergone removal of ACFB using a prism contact lens and 23-gauge foreign body forceps from January 2008 to October 2013 were collected and analyzed. Twenty eyes in group A received the conventional approach by using toothed forceps through corneal limbus incision, and 22 eyes in group B underwent the novel method through the opposite corneal limbus incision. The success rate of ACFB once removal was 75% (15/20) in group A, and 100% (22/22) in group B. The average operation time of group A was significantly longer compared with group B (34.9±9.88min vs 22.13±8.85min; P contact lens and 23-gauge foreign body forceps is a safer, more effective, and convenient technique compared with the conventional approach.

  16. A Novel Anti-Spoofing Solution for Iris Recognition Toward Cosmetic Contact Lens Attack Using Spectral ICA Analysis

    Science.gov (United States)

    Hsieh, Sheng-Hsun; Wang, Wei; Tien, Chung-Hao

    2018-01-01

    In this study, we maneuvered a dual-band spectral imaging system to capture an iridal image from a cosmetic-contact-lens-wearing subject. By using the independent component analysis to separate individual spectral primitives, we successfully distinguished the natural iris texture from the cosmetic contact lens (CCL) pattern, and restored the genuine iris patterns from the CCL-polluted image. Based on a database containing 200 test image pairs from 20 CCL-wearing subjects as the proof of concept, the recognition accuracy (False Rejection Rate: FRR) was improved from FRR = 10.52% to FRR = 0.57% with the proposed ICA anti-spoofing scheme. PMID:29509692

  17. A Novel Anti-Spoofing Solution for Iris Recognition Toward Cosmetic Contact Lens Attack Using Spectral ICA Analysis

    Directory of Open Access Journals (Sweden)

    Sheng-Hsun Hsieh

    2018-03-01

    Full Text Available In this study, we maneuvered a dual-band spectral imaging system to capture an iridal image from a cosmetic-contact-lens-wearing subject. By using the independent component analysis to separate individual spectral primitives, we successfully distinguished the natural iris texture from the cosmetic contact lens (CCL pattern, and restored the genuine iris patterns from the CCL-polluted image. Based on a database containing 200 test image pairs from 20 CCL-wearing subjects as the proof of concept, the recognition accuracy (False Rejection Rate: FRR was improved from FRR = 10.52% to FRR = 0.57% with the proposed ICA anti-spoofing scheme.

  18. Toric implantable collamer lens for keratoconus

    Directory of Open Access Journals (Sweden)

    Mathew Kurian Kummelil

    2013-01-01

    Full Text Available Keratoconus is a progressive non-inflammatory thinning of the cornea that induces myopia and irregular astigmatism and decreases the quality of vision due to monocular diplopia, halos, or ghost images. Keratoconus patients unfit for corneal procedures and intolerant to refractive correction by spectacles or contact lenses have been implanted toric posterior chamber phakic intraocular lenses (PC pIOLs alone or combined with other surgical procedures to correct the refractive errors associated with keratoconus as an off label procedure with special informed consent from the patients. Several reports attest to the safety and efficacy of the procedure, though the associated corneal higher order aberrations would have an impact on the final visual quality.

  19. Simple fabrication of back contact heterojunction solar cells by plasma ion implantation

    Science.gov (United States)

    Koyama, Koichi; Yamaguchi, Noboru; Hironiwa, Daisuke; Suzuki, Hideo; Ohdaira, Keisuke; Matsumura, Hideki

    2017-08-01

    A back-contact amorphous-silicon (a-Si)/crystalline silicon (c-Si) heterojunction is one of the most promising structures for high-efficiency solar cells. However, the patterning of back-contact electrodes causes the increase in fabrication cost. Thus, to simplify the fabrication of back-contact cells, we attempted to form p-a-Si/i-a-Si/c-Si and n-a-Si/i-a-Si/c-Si regions by the conversion of a patterned area of p-a-Si/i-a-Si/c-Si to n-a-Si/i-a-Si/c-Si by plasma ion implantation. It is revealed that the conversion of the conduction type can be realized by the plasma ion implantation of phosphorus (P) atoms into p-a-Si/i-a-Si/c-Si regions, and also that the quality of passivation can be kept sufficiently high, the same as that before ion implantation, when the samples are annealed at around 250 °C and also when the energy and dose of ion implantation are appropriately chosen for fitting to a-Si layer thickness and bulk c-Si carrier density.

  20. Design of retinal-projection-based near-eye display with contact lens.

    Science.gov (United States)

    Wu, Yuhang; Chen, Chao Ping; Mi, Lantian; Zhang, Wenbo; Zhao, Jingxin; Lu, Yifan; Guo, Weiqian; Yu, Bing; Li, Yang; Maitlo, Nizamuddin

    2018-04-30

    We propose a design of a retinal-projection-based near-eye display for achieving ultra-large field of view, vision correction, and occlusion. Our solution is highlighted by a contact lens combo, a transparent organic light-emitting diode panel, and a twisted nematic liquid crystal panel. Its design rules are set forth in detail, followed by the results and discussion regarding the field of view, angular resolution, modulation transfer function, contrast ratio, distortion, and simulated imaging.

  1. Phacoemulsification with intraocular lens implantation in primary angle-closure suspect, primary angle-closure and primary angle-closure glaucoma with cataract

    Directory of Open Access Journals (Sweden)

    Kun Zeng

    2013-08-01

    Full Text Available AIM: To evaluate the features and clinical outcomes of cataract extraction by phacoemulsification with intraocular lens implantation in primary angle-closure suspect(PACS, primary angle-closure(PACand primary angle-closure glaucoma(PACGwith cataract.METHODS:Phacoemulsification with intraocular lens implantation was performed on 86 cases(86 eyesdiagnosed as PACS, PAC and PACG co-existing cataract from January to December 2012. All cases were followed up for 3 months to 1 year. Pre-operative and post-operative visual acuity, intraocular pressure(IOP, gonioscopy, ultrasound biomicroscopy(UBM, visual field and usage of anti-glaucomaous eye drops were recorded.RESULTS:Zonular dialysis existed in 19 eyes(22%. The post-operative visual acuity improved in 84 eyes(98%. The post-operative visual acuity was CONCLUSION: PACS, PAC and PACG co-existing zonular dialysis is common. Phacoemulsification with IOL implantation can reduce IOP, deepen anterior chamber and open angle.

  2. Comparison on the visual quality after different multifocal lens implantation in cataract patients

    Directory of Open Access Journals (Sweden)

    Si-Meng Qu

    2018-02-01

    Full Text Available AIM: To compare the visual quality after different multifocal lens(MIOLimplantation in cataract patients. METHODS:Totally 78 cases(78 eyesof cataract patients who receiving phacoemulsification and implantation of different MIOL were enrolled from February 2016 to June 2017 in our hospital. According to the different type of implanted MIOL, the 78 cases(78 eyeswere divided Group A, B and C, each group was 26 cases(26 eyes. Patients in the Group A were implanted regional refraction MIOL SBL-3; patients in the Group B implanted step progressive diffraction MIOL SN6AD1; patients in the Group C implanted all-optical plane diffraction MIOL Tecnis ZMB00. The visual acuity, contrast sensitivity, defocus testing, contrast visual acuity and satisfaction of visual quality were compared in 3 groups at postoperative 3mo. RESULTS: There was no statistically significant difference in postoperative adverse reactions between the three groups(P>0.05. There was statistical difference in uncorrected intermediate visual acuity, uncorrected near visual acuity, distance-corrected intermediate visual acuity and distance-corrected near visual acuity in 3 groups(PPPPPPPPPCONCLUSION:The region refraction MIOL SBL-3 not only could provide better distant, intermediate and near visual acuity, but also could provide better contrast sensitivity and contrast visual acuity, thereby greatly increase visual quality satisfaction.

  3. Nonadhesive, silica nanoparticles-based brush-coated contact lens cases--compromising between ease of cleaning and microbial transmission to contact lenses.

    Science.gov (United States)

    Qu, Wenwen; Hooymans, Johanna M M; Qiu, Jun; de-Bont, Nik; Gelling, Onko-Jan; van der Mei, Henny C; Busscher, Henk J

    2013-05-01

    Surface properties of lens cases are determinant for their cleanability and for microbial transmission from lens cases to contact lenses (CLs). PEG-polymer-brush-coatings are known to decrease microbial adhesion more than other surface-coatings. Here, we applied a robust, silica nanoparticles-based brush-coating to polypropylene cases to evaluate their ease of cleaning and probability of bacterial transmission to CLs. Adhesion forces of nine bacterial strains (Pseudomonas, Staphylococci, and Serratia) to rigid CLs, polypropylene, and silica nanoparticles-based brush-coated polypropylene were measured using atomic-force-microscopy and subjected to Weibull analyses to yield bacterial transmission probabilities. Biofilms of each strain were grown in coated and uncoated cases and rinsed with a NaCl or antimicrobial lens care solution. Residual, viable organisms were quantified. Bacterial adhesion forces of all strains were significantly, up to tenfold smaller on brush-coated than on uncoated polypropylene. This yielded, higher transmission probabilities to a CL, but mild-rinsing yielded 10-100 fold higher removal of bacteria from brush-coated than from polypropylene cases. Moreover, due to weak adhesion forces, bacteria on brush-coated cases were two-to-three fold more susceptible to an antimicrobial lens care solution than on polypropylene cases. Therewith, the design of lens case surfaces is a compromise between ease of cleaning and transmission probability to CLs. Copyright © 2013 Wiley Periodicals, Inc.

  4. Results from a global survey of contact lens-wearer satisfaction with OPTI-FREE® PureMoist® Multi-Purpose Disinfecting Solution

    Directory of Open Access Journals (Sweden)

    Lemp J

    2013-11-01

    Full Text Available Jessie Lemp, Jami R Kern Global Medical Affairs, Alcon Laboratories, Inc, Fort Worth, Texas, USA Purpose: The objective of the study reported here was to obtain information on acceptance and satisfaction with OPTI-FREE® PureMoist® Multi-Purpose Disinfecting Solution (MPDS from contact lens wearers globally. Methods: Eligible contact lens wearers provided baseline demographic and lens-wear-regimen information, and advised their ocular dryness/discomfort level and current lens-wear experience. Volunteers received OPTI-FREE PureMoist MPDS and a survey consisting of ten statements about the trial solution. Volunteers were instructed to use the solution daily and to complete the survey after 2 weeks of use. Descriptive statistical analysis was conducted on data from the entire group, from the subset of respondents reporting ocular dryness and/or discomfort at trial initiation (symptomatic subgroup, and from each geographic region. Results: Volunteers from nine countries returned 10,610 surveys, in which 50% of respondents classified themselves as having ocular dryness/discomfort. Lens comfort and visual performance responses from the total population and the symptomatic subgroup were significantly more positive after 2 weeks of OPTI-FREE PureMoist use than at baseline, irrespective of the habitual lens-care solution. In the USA, Southeast Asia, and Europe, 14% to 20% more respondents reported that their contact lenses provided all-day comfort after 2 weeks of OPTI-FREE PureMoist use compared with baseline (P<0.0001. Australia reported 31% more patients with all-day comfort after OPTI-FREE PureMoist use (P<0.0001. Approximately four out of five respondents from both populations reported their intent to continue using OPTI-FREE PureMoist. Globally, 39% of all respondents and 58% of symptomatic respondents experienced reduced end-of-day dryness with their contact lenses after use of OPTI-FREE PureMoist (P<0.0001. Conclusion: Results from this large

  5. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-01-01

    Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05). Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division

  6. Safety and efficacy of topical azithromycin ophthalmic solution 1.0% in the treatment of contact lens-related dry eye.

    Science.gov (United States)

    Nichols, Jason J; Bickle, Katherine M; Zink, Richard C; Schiewe, Michael D; Haque, Reza M; Nichols, Kelly K

    2012-03-01

    The purpose of this pilot study was to evaluate the safety and efficacy of azithromycin ophthalmic solution 1% in patients with contact lens-related dry eye (CLDE). This was a 4-week, single-center, open-label clinical trial in patients diagnosed with CLDE using the Contact Lens Dry Eye Questionnaire (CLDEQ). Fifty patients were enrolled in this study. The patients were randomized to 1 of 2 treatment groups: azithromycin ophthalmic solution administered bid on days 1 and 2 and on days 3 to 29±1 or Visine for Contacts rewetting drops administered qid on days 1 to 29±1. The patient diaries were used daily to collect data on comfortable and total contact lens wear time and ocular dryness throughout the treatment period. Tear osmolarity, fluorescein corneal staining, and visual acuity were also assessed during clinic visits. Fifty patients were enrolled, and 44 completed the study. One patient discontinued in the azithromycin group, and five patients discontinued in the rewetting drops group because of adverse events. A statistically significant increase in mean comfortable contact lens wear time from baseline was observed for the subjects treated with azithromycin ophthalmic solution as compared with the subjects treated with rewetting drops at week 4 (P=0.004; primary endpoint), in addition to weeks 2 and 3. The improvement in the mean comfortable wear time for the patients in the azithromycin treatment group exceeded 2 hrs throughout the treatment period (weeks 1-4). No significant differences were observed between the groups for total wear time, low contrast visual acuity, or tear osmolarity. Subject-rated ocular dryness (PM time assessments) was significantly improved from baseline in the subjects treated with azithromycin ophthalmic solution as compared with those treated with rewetting drops at weeks 2 and 3 endpoints (P=0.015 for each week). Additionally, a statistical difference was observed in favor of the azithromycin treatment group at week 2 for the

  7. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Rui Wang

    2014-04-01

    Full Text Available AIM:To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL implantation.METHODS:Non-comparative retrospective observational case series. Participants:30 cases (30 eyes of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi''an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures:visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations.RESULTS: The follow-up time was 11-36mo (21.4±7.13. Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL

  8. The effects of the modulus of the lens material on intraocular pressure measurement through soft contact lenses.

    Science.gov (United States)

    Boyraz, S; Güngör, I

    2013-09-01

    To investigate the effects of the modulus of the lens material on the intraocular pressure measurement using the Tono-Pen XL applanation tonometer through soft contact lenses. Thirty eyes of 15 patients with myopia were evaluated. Intraocular pressure (IOP) measurements were performed using Tono-Pen XL directly over cornea, and subsequently through three soft contact lenses made up of different lens materials. All were -3.00 diopter soft contact lenses: lotrafilcon A with a low water content (24%) and high modulus (1.4 MPa) (CL-I), balafilcon A with a moderate water content (36%) and moderate modulus (1.1 MPa) (CL-II), and vifilcon A with a moderate water content (55%) and low modulus (0.79 MPa) (CL-III). IOP measurements through contact lenses were compared with each other, and with direct corneal measurements. The mean age of the patients (11 males and 4 females) was 26.86±5.62 years. All measurements obtained through CLs were significantly higher than the direct corneal measurements. The measurements through CLs differed by 4.61±0.54 mmHg (P=0,001), 2.9±0.46 mmHg (P=0.001), and 1.94±0.51 mmHg (P=0,003) for CL-I, CL-II and CL-III, respectively. In the paired comparisons of measurements through CLs, all comparisons were significant except the comparison of measurements through CL-II and CL-III (P=0.128). IOP measurements through silicone-hydrogel contact lenses with a high modulus and low water content were higher compared to the other contact lenses. While measuring IOP through CLs, the clinicians should consider the effect of the lens material and the features of the device used.

  9. Is purchasing lenses from the prescriber associated with better habits among soft contact lens wearers?

    Science.gov (United States)

    Chalmers, Robin L; Wagner, Heidi; Kinoshita, Beth; Sorbara, Luigina; Mitchell, G Lynn; Lam, Dawn; Richdale, Kathryn; Zimmerman, Aaron

    2016-12-01

    To compare the habits of United States (US) soft contact lens (SCL) wearers who bought SCLs from their eye care practitioner (ECP), on the internet/telephone, or at retail (not where they were examined) to test the effect of proximity to the prescriber on SCL wear and care practices. Adult SCL wearers completed an adapted Contact Lens Risk Survey (CLRS) online that queried items related to risk factors for SCL-related complications. Responses from subjects who purchased at the ECP, via the internet/telephone, or at a retail store were compared (Chi-Square). Purchase sources were: ECP 646 (67%, 44±12 yrs, 17% male), Retail 104 (11%, 45±13 yrs, 28% male), and Internet/telephone 218 (23%, 45±12 yrs, 18% male); age (p=0.51), gender (p=0.021). Internet purchasers had fewer annual eye exams (79% ECP, 83% retail, 66% internet/telephone, p=0.007), purchased more hydrogel SCLs (34% ECP, 29% retail, 45% internet/telephone, p=0.0034), and paid for SCLs with insurance less often (39% ECP, 29% retail, 19% internet/telephone, p0.05). In this sample, the purchase location of SCL wearers had limited impact on known risk factors for SCL-related complications. Internet purchasers reported less frequent eye exams and were more likely to be wearing hydrogel SCLs. Closer access to the ECP through in-office SCL purchase did not improve SCL habits or reduce the prevalence of risk behaviors. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  10. IBC c-Si solar cells based on ion-implanted poly-silicon passivating contacts

    NARCIS (Netherlands)

    Yang, G.; Ingenito, A.; Isabella, O.; Zeman, M.

    2016-01-01

    Ion-implanted poly-crystalline silicon (poly-Si), in combination with a tunnel oxide layer, is investigated as a carrier-selective passivating contact in c-Si solar cells based on an interdigitated back contact (IBC) architecture. The optimized poly-Si passivating contacts enable low interface

  11. Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: a systematic review

    NARCIS (Netherlands)

    Meursinge Reynders, Reint; Ladu, Luisa; Ronchi, Laura; Di Girolamo, Nicola; de Lange, Jan; Roberts, Nia; Plüddemann, Annette

    2016-01-01

    Most orthodontic mini-implants (OMIs) are inserted between dental roots. The prevalence of contacting these structures is high. Such contacts can cause permanent root damage and implant instability. Increased torque levels during implant insertion (the index test) could be a more accurate and

  12. An evaluation of 1-day disposable contact lens wear in a population of allergy sufferers.

    Science.gov (United States)

    Hayes, Valérie Y; Schnider, Cristina M; Veys, Jane

    2003-06-01

    This was a multi-site, 128-subject, bilateral crossover study to evaluate subjective comfort and slit-lamp findings with 1-day disposable contact lenses in a population of allergy sufferers during periods when allergen levels were elevated. The study involved 1-month of single-use daily wear with a 1-day disposable test lens (1. DAY ACUVUE Brand Contact Lenses, Johnson & Johnson Vision Care) and 1-month of daily wear with subjects' habitual lenses replaced to their usual replacement schedule. Pollen and mould counts were obtained for each site 1 week prior to the study and twice weekly throughout the study period. Subjective comfort and slit-lamp findings were recorded at baseline and after 1-month's wear of each modality. Sixty-seven percent of subjects agreed that the 1-day disposable lenses provided improved comfort when compared to the lenses they wore prior to the study, compared with 18% agreeing that the new pair of habitual lenses provided improved comfort. The 1-day disposable lenses showed greater improvement in slit-lamp findings from baseline than new habitual lenses. The use of 1-day disposable lenses is an effective strategy for managing allergy-suffering contact lens wearers.

  13. Implant-Abutment Contact Surfaces and Microgap Measurements of Different Implant Connections Under 3-Dimensional X-Ray Microtomography.

    Science.gov (United States)

    Scarano, Antonio; Valbonetti, Luca; Degidi, Marco; Pecci, Raffaella; Piattelli, Adriano; de Oliveira, P S; Perrotti, Vittoria

    2016-10-01

    The presence of a microgap between implant and abutment could produce a bacterial reservoir which could interfere with the long-term health of the periimplant tissues. The aim of this article was to evaluate, by x-ray 3-dimensional microtomography, implant-abutment contact surfaces and microgaps at the implant-abutment interface in different types of implant-abutment connections. A total of 40 implants were used in this in vitro study. Ten implants presented a screw-retained internal hexagon abutment (group I), 10 had a Morse Cone taper internal connection (group II), 10 another type of Morse Cone taper internal connection (group III), and 10 had a screwed trilobed connection (group IV). In both types of Morse Cone internal connections, there was no detectable separation at the implant-abutment in the area of the conical connection, and there was an absolute congruity without any microgaps between abutment and implant. No line was visible separating the implant and the abutment. On the contrary, in the screwed abutment implants, numerous gaps and voids were present. The results of this study support the hypothesis that different types of implant-abutment joints are responsible for the observed differences in bacterial penetration.

  14. [Visual rehabilitation of patients with large post-traumatic defects of the anterior eye segment through iris-lens diaphragm implantation].

    Science.gov (United States)

    Khodzhaev, N S; Sobolev, N P; Mushkova, I A; Izmaylova, S B; Karimova, A N

    The diversity of methodological approaches and lack of pathogenetically reasonable tactics for patients with combined ocular injuries became the basis for the development and systematization of surgical rehabilitation stages of patients, in whom post-traumatic cataract is combined with post-traumatic aniridia and corneal scarring. to construct a visual rehabilitation approach to patients with post-traumatic defects of the anterior eye segment following optical-reconstructive surgery that involved implantation of an iris-lens diaphragm (ILD). We have analyzed 80 reconstructive cases with ILD implantation in patients with post-traumatic aniridia and corneal damage. These patients constituted the first study group (Group 1). We have also investigated 58 eyes with residual ametropy and stable visual function 1 year after ILD implantation before and after conducting a laser keratorefractive surgery. These patients were assigned to the second study group (Group 2). Rehabilitation approach to patients after anterior segment injuries that has been proposed allows to achieve high clinical and functional results and reduce the risk of intra- and postoperative complications. The proposed approach to patients after optical-reconstructive surgery with iris-lens diaphragm implantation followed by keratorefractive surgery is an effective method of visual rehabilitation of anterior eye segment post-traumatic defects.

  15. Performance of Lotrafilcon B silicone hydrogel contact lenses in experienced low-Dk/t daily lens wearers.

    Science.gov (United States)

    Dillehay, Sally M; Miller, Marian B

    2007-11-01

    The silicone hydrogel lens O2OPTIX with a Dk/t of 138 (at -3.00 diopters [D]) was evaluated and compared with patients' habitual low-Dk/t lenses. This large, multisite (United States and Canada), single-masked study enrolled experienced daily-wear, low-Dk/t, 2-week replacement soft contact lens wearers. Subjects underwent baseline evaluations and were fitted with O2OPTIX lenses for a 2-week period. After 2 weeks, subjects returned for assessment versus their habitual lenses. Data for 760 subjects were analyzed. The overall average habitual contact lens power was -3.13 D, and the average O2OPTIX lens power was -3.22 D. Biomicroscopy evaluations showed improvements in signs related to corneal health with O2OPTIX. Conjunctival and limbal redness, corneal neovascularization, corneal edema, and corneal and conjunctival staining all decreased significantly from baseline. O2OPTIX lenses performed better than habitual lenses in terms of comfort, symptoms, and overall preference. When wearing O2OPTIX lenses, significantly fewer subjects reported problems compared to their habitual lenses, including uncomfortable lens wear (-20.3%), redness (-44.5%), dryness during the day (-40.2%), and dryness at the end of the day (-34.4%); 47.9% reported that they could wear O2OPTIX lenses longer than their habitual lenses. At the end of study, among those with a preference, a significantly greater proportion of patients (60.3%) preferred O2OPTIX lenses to their habitual lenses. Daily wear of O2OPTIX lenses resulted in improvements in corneal signs of health and patient symptoms and provided excellent vision and comfort. O2OPTIX lenses were preferred by subjects over their habitual lenses.

  16. NMOS contact resistance reduction with selenium implant into NiPt silicide

    Science.gov (United States)

    Rao, K. V.; Khaja, F. A.; Ni, C. N.; Muthukrishnan, S.; Darlark, A.; Lei, J.; Peidous, I.; Brand, A.; Henry, T.; Variam, N.; Erokhin, Y.

    2012-11-01

    A 25% reduction in NMOS contact resistance (Rc) was achieved by Selenium implantation into NiPt silicide film in VIISta Trident high-current single-wafer implanter. The Trident implanter is designed for shallow high-dose implants with high beam currents to maintain high throughput (for low CoO), with improved micro-uniformity and no energy contamination. The integration of Se implant was realized using a test chip dedicated to investigating silicide/junction related electrical properties and testable after silicidation. The silicide module processes were optimized, including the pre-clean (prior to RF PVD NiPt dep) and pre- and post-implant anneals. A 270°C soak anneal was used for RTP1, whereas a msec laser anneal was employed for RTP2 with sufficient process window (800-850°C), while maintaining excellent junction characteristics without Rs degradation.

  17. Lente de contato em crianças: aspectos epidemiológicos Contact lens in children: epidemiological aspects

    Directory of Open Access Journals (Sweden)

    André Luiz Alves Salame

    2008-06-01

    Full Text Available OBJETIVO: Traçar o perfil epidemiológico de crianças encaminhadas para adaptação de lente de contato. MÉTODOS: Foi realizado estudo retrospectivo de pacientes registrados no Setor de lente de contato da Universidade Federal de São Paulo. Os pacientes com até 12 anos de idade foram avaliados quanto ao sexo, idade, diagnóstico, indicação e tipo de lente de contato testada na primeira consulta. RESULTADOS: Dos 73 prontuários avaliados, 34 (46,6% pertenciam a crianças do sexo masculino e 39 (53,4% a crianças do sexo feminino. A idade variou de 2 a 12 com média de 10,2 e desvio-padrão de 2,42 anos. O diagnóstico mais encontrado foi afacia em 16 (21,9% crianças, seguido de ceratocone em 14 (19,1%, leucoma em 11 (15%, anisometropia em 10 (13,7%, ametropia em 9 (12,3%, astigmatismo irregular em 7 (9,5% e ectopia lentis em 4 (5,4%. Uma criança era alta míope (1,3% e outra emétrope (1,3% que possuía desejo de usar lente de contato estética. Em relação às indicações, 52 (71,2% pacientes tinham indicação médica, 9 (12,3% indicação óptica e 12 (16,4% indicação cosmética. Foram testadas lentes em 103 olhos sendo as mais testadas a rígida gás permeável esférica em 43 (41,7%, a gelatinosa esférica em 41 (39,8% e a gelatinosa cosmética em 11 (10,6%. CONCLUSÃO: O perfil epidemiológico dos usuários de lente de contato nessa faixa etária tem como diagnóstico mais prevalente a afacia, a indicação mais freqüente a de ordem médica e a lente mais testada a rígida gás permeável esférica.PURPOSE: To describe the epidemiology of children submitted to contact lens fit. METHODS: Retrospective study of 73 children that had been submitted to contact lens fit at the "Universidade Federal de São Paulo". This study analyzed sex distribution, age, diagnosis, indications and contact lens fitted at first examination. RESULTS: 34 children (46.6% were male and 39 (53.4% female, aged between 2 and 12 years with mean of 10.2 and

  18. Modelling the evaporation of a tear film over a contact lens.

    Science.gov (United States)

    Talbott, Kevin; Xu, Amber; Anderson, Daniel M; Seshaiyer, Padmanabhan

    2015-06-01

    A contact lens (CL) separates the tear film into a pre-lens tear film (PrLTF), the fluid layer between the CL and the outside environment, and a post-lens tear film (PoLTF), the fluid layer between the CL and the cornea. We examine a model for evaporation of a PrLTF on a modern permeable CL allowing fluid transfer between the PrLTF and the PoLTF. Evaporation depletes the PrLTF, and continued evaporation causes depletion of the PoLTF via fluid loss through the CL. Governing equations include Navier-Stokes, heat and Darcy's equations for the fluid flow and heat transfer in the PrLTF and porous layer. The PoLTF is modelled by a fixed pressure condition on the posterior surface of the CL. The original model is simplified using lubrication theory for the PrLTF and CL applied to a sagittal plane through the eye. We obtain a partial differential equation (PDE) for the PrLTF thickness that is first-order in time and fourth-order in space. This model incorporates evaporation, conjoining pressure effects in the PrLTF, capillarity and heat transfer. For a planar film, we find that this PDE can be reduced to an ordinary differential equation (ODE) that can be solved analytically or numerically. This reduced model allows for interpretation of the various system parameters and captures most of the basic physics contained in the model. Comparisons of ODE and PDE models, including estimates for the loss of fluid through the lens due to evaporation, are given. © The Authors 2014. Published by Oxford University Press on behalf of the Institute of Mathematics and its Applications. All rights reserved.

  19. Proper balance of omega-3 and omega-6 fatty acid supplements with topical cyclosporine attenuated contact lens-related dry eye syndrome.

    Science.gov (United States)

    Wang, Ling; Chen, Xi; Hao, Jingfang; Yang, Lu

    2016-12-01

    Essential fatty acids had been applied in the treatment of dry eye syndrome (DES), but the effects of different combinations of fatty acids have not been investigated. 360 long-term contact lens wearers were included in this double-blinded study. Omega-3 and omega-6 fatty acids were combined in different ratios and supplied to the participants that were randomly divided into six groups, and the effects of different essential fatty acids mixture on DES with or without topical cyclosporine were investigated. More than half of long-term contact lens wearers suffered from DES, which were found to be attenuated by oral supplement of properly balanced O3FA and O6FA fatty acid. The topical cyclosporine treatment considerably inhibited the production of cytokines compared to the cyclosporine negative groups, which further relieved DES. Proper balance of omega-3 and omega-6 fatty acid combination significantly alleviated contact lens-related DES.

  20. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  1. Bacterial Colonization of Disposable Soft Contact Lenses Is Greater during Corneal Infiltrative Events than during Asymptomatic Extended Lens Wear

    Science.gov (United States)

    Sankaridurg, Padmaja R.; Sharma, Savitri; Willcox, Mark; Naduvilath, Thomas J.; Sweeney, Deborah F.; Holden, Brien A.; Rao, Gullapalli N.

    2000-01-01

    Microorganisms, especially gram-negative bacteria, are considered to play a role in the etiology of certain corneal infiltrative events (CIEs) observed during soft contact lens wear. This study explored the possibility of microbial colonization of soft contact lenses as a risk factor leading to CIEs. In a clinical trial conducted from March 1993 to January 1996, 330 subjects wore disposable soft contact lenses on a 6-night extended-wear and disposal schedule. During this period, 4,321 lenses (118 during CIEs; 4,203 during asymptomatic lens wear) were recovered aseptically and analyzed for microbial colonization. A greater percentage of lenses were free from microbial colonization during asymptomatic wear than during CIEs (42 versus 23%; P bacteria, gram-negative bacteria and fungi was greater during CIEs than during asymptomatic lens wear (P bacteria were isolated most frequently and were usually normal external ocular microbiota. Of the gram-positive bacteria, the incidence of Streptococcus pneumoniae was greater during CIE than during asymptomatic wear (7.6 versus 0.6%; P bacteria were seen in few cases during asymptomatic wear, their incidence during CIE in comparison to asymptomatic wear was substantial and significant (23.7 versus 3.8%; P bacteria or S. pneumoniae. Colonization of soft contact lenses with pathogenic bacteria, especially gram-negative bacteria and S. pneumoniae, appears to be a significant risk factor leading to CIE. PMID:11101574

  2. Extended Release of an Anti–Heparan Sulfate Peptide From a Contact Lens Suppresses Corneal Herpes Simplex Virus-1 Infection

    Science.gov (United States)

    Jaishankar, Dinesh; Buhrman, Jason S.; Valyi-Nagy, Tibor; Gemeinhart, Richard A.; Shukla, Deepak

    2016-01-01

    Purpose To prolong the release of a heparan sulfate binding peptide, G2-C, using a commercially available contact lens as a delivery vehicle and to demonstrate the ability of the released peptide to block herpes simplex virus-1 (HSV-1) infection using in vitro, ex vivo, and in vivo models of corneal HSV-1 infection. Methods Commercially available contact lenses were immersed in peptide solution for 5 days prior to determining the release of the peptide at various time points. Cytotoxicity of the released samples was determined by MTT and cell cycle analysis, and the functional activity of the released samples were assessed by viral entry, and viral spread assay using human corneal epithelial cells (HCE). The ability to suppress infection in human and pig cornea ex vivo and mouse in vivo models were also assessed. Results Peptide G2-C was released through the contact lens. Following release for 3 days, the peptide showed significant activity by inhibiting HSV-1 viral entry and spread in HCE cells. Significant suppression of infection was also observed in the ex vivo and in vivo experiments involving corneas. Conclusions Extended release of an anti–HS peptide through a commercially available contact lens can generate significant anti–HSV-1 activity and provides a new and effective way to control corneal herpes. PMID:26780322

  3. Bacterial adhesion to conventional hydrogel and new silicone-hydrogel contact lens materials.

    Science.gov (United States)

    Kodjikian, Laurent; Casoli-Bergeron, Emmanuelle; Malet, Florence; Janin-Manificat, Hélène; Freney, Jean; Burillon, Carole; Colin, Joseph; Steghens, Jean-Paul

    2008-02-01

    As bacterial adhesion to contact lenses may contribute to the pathogenesis of keratitis, the aim of our study was to investigate in vitro adhesion of clinically relevant bacteria to conventional hydrogel (standard HEMA) and silicone-hydrogel contact lenses using a bioluminescent ATP assay. Four types of unworn contact lenses (Etafilcon A, Galyfilcon A, Balafilcon A, Lotrafilcon B) were incubated with Staphylococcus epidermidis (two different strains) and Pseudomonas aeruginosa suspended in phosphate buffered saline (PBS). Lenses were placed with the posterior surface facing up and were incubated in the bacterial suspension for 4 hours at 37 degrees C. Bacterial binding was then measured and studied by bioluminescent ATP assay. Six replicate experiments were performed for each lens and strain. Adhesion of all species of bacteria to standard HEMA contact lenses (Etafilcon A) was found to be significantly lower than that of three types of silicone-hydrogel contact lenses, whereas Lotrafilcon B material showed the highest level of bacterial binding. Differences between species in the overall level of adhesion to the different types of contact lenses were observed. Adhesion of P. aeruginosa was typically at least 20 times greater than that observed with both S. epidermidis strains. Conventional hydrogel contact lenses exhibit significantly lower bacterial adhesion in vitro than silicone-hydrogel ones. This could be due to the greater hydrophobicity but also to the higher oxygen transmissibility of silicone-hydrogel lenses.

  4. Effect of Daily Contact Lens Cleaning on Ocular Adverse Events during Extended Wear.

    Science.gov (United States)

    Ozkan, Jerome; Rathi, Varsha M; de la Jara, Percy Lazon; Naduvilath, Thomas; Holden, Brien A; Willcox, Mark D P

    2015-02-01

    The purpose of the study was to assess what effect daily cleaning of contact lenses with a multipurpose disinfection solution (MPDS), during 30 nights extended wear, would have on contact lens-related adverse events. This was a prospective, open-label, randomized, controlled, parallel-group, 3-month clinical study in which 193 participants were dispensed with lotrafilcon A silicone hydrogel lenses for a 30-day extended-wear schedule and with lenses replaced monthly. Participants were randomized to a control or test group. Test subjects were required to remove lenses daily after waking, clean them with the MPDS, and reinsert the lenses. Control subjects wore lenses without removal for 30 days extended wear. Handling-related lens contamination was assessed at the baseline visit. There was no significant difference between the test and control groups for the incidence of significant corneal infiltrative events (1.3 vs. 4.9%, p = 0.368), total corneal infiltrative events (2.6 vs. 4.9%, p = 0.682), or mechanical events (1.3 vs. 2.5%, p = 1.00). The test group had greater corneal staining (p lenses) resulted in isolation of Gram-positive bacteria from 92.5% of test lenses compared with 87.5% of control lenses (p = 0.712). Gram-negative bacteria were isolated from 5% of test subjects compared with 2.5% of control subjects (p = 1.00). Fungus was isolated from 2.5% of subjects in both the test and control groups (p = 1.00). The intervention of daily morning cleaning of the lens surface with an MPDS during extended wear did not significantly influence the incidence of adverse events.

  5. Bottom-up fabrication of zwitterionic polymer brushes on intraocular lens for improved biocompatibility

    Directory of Open Access Journals (Sweden)

    Han Y

    2016-12-01

    Full Text Available Yuemei Han,1,* Xu Xu,1,* Junmei Tang,1,* Chenghui Shen,2 Quankui Lin,1,2 Hao Chen1,2 1School of Ophthalmology & Optometry, Eye Hospital, Wenzhou Medical University, 2Wenzhou Institute of Biomaterials and Engineering, Chinese Academy of Sciences, Wenzhou, People’s Republic of China *These authors contributed equally to this work Abstract: Intraocular lens (IOL is an efficient implantable device commonly used for treating cataracts. However, bioadhesion of bacteria or residual lens epithelial cells on the IOL surface after surgery causes postoperative complications, such as endophthalmitis or posterior capsular opacification, and leads to loss of sight again. In the present study, zwitterionic polymer brushes were fabricated on the IOL surface via bottom-up grafting procedure. The attenuated total reflection-Fourier transform infrared and contact angle measurements indicated successful surface modification, as well as excellent hydrophilicity. The coating of hydrophilic zwitterionic polymer effectively decreased the bioadhesion of lens epithelial cells or bacteria. In vivo intraocular implantation results showed good in vivo biocompatibility of zwitterionic IOL and its effectiveness against postoperative complications. Keywords: RAFT, surface modification, endophthalmitis, PCO, in vivo

  6. Impact of lens case hygiene guidelines on contact lens case contamination.

    Science.gov (United States)

    Wu, Yvonne T; Teng, Yuu Juan; Nicholas, Mary; Harmis, Najat; Zhu, Hua; Willcox, Mark D P; Stapleton, Fiona

    2011-10-01

    Lens case contamination is a risk factor for microbial keratitis. The effectiveness of manufacturers' lens case cleaning guidelines in limiting microbial contamination has not been evaluated in vivo. This study compared the effectiveness of manufacturers' guidelines and an alternative cleaning regimen. A randomized cross-over clinical trial with two phases (n = 40) was performed. Participants used the lens types of their choice in conjunction with the provided multipurpose solution (containing polyhexamethylene biguanide) for daily wear. In the manufacturers' guideline phase, cases were rinsed with multipurpose solution and air dried. In the alternative regimen phase, cases were rubbed, rinsed with solution, tissue wiped, and air-dried face down. The duration of each phase was 1 month. Lens cases were collected at the end of each phase for microbiological investigation. The levels of microbial contamination were compared, and compliance to both regimens was assessed. The case contamination rate was 82% (32/39) in the manufacturers' guideline group, compared with 72% (28/39) in the alternative regimen group. There were significantly fewer (p = 0.004) colony forming units (CFU) of bacteria from cases used by following the alternative regimen (CFU range of 0 to 10, and median of 12 CFU per well) compared with that of the manufacturer's guidelines (CFU range of 0 to 10, and median of 28 CFU per well). The compliance level between both guidelines was not significantly different (p > 0.05). The alternative guidelines are more effective in eliminating microbial contamination from lens cases than that of the current manufacturer's guideline. Simply incorporating rubbing and tissue-wiping steps in daily case hygiene reduces viable organism contamination.

  7. Nanostructured implant surface effect on osteoblast gene expression and bone-to-implant contact in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Mendonca, Gustavo, E-mail: gustavo_mendonca@dentistry.unc.edu [Universidade Catolica de Brasilia, Pos-Graduacao em Ciencias Genomicas e Biotecnologia, SGAN Quadra 916, Modulo B, Av. W5 Norte 70.790-160-Asa Norte Brasilia/DF (Brazil); Bone Biology and Implant Therapy Laboratory, Department of Prosthodontics, University of North Carolina at Chapel Hill, 404 Brauer Hall, CB 7450, Chapel Hill, NC 27511 (United States); Universidade Catolica de Brasilia, Curso de Odontologia, Taguatinga/DF (Brazil); Baccelli Silveira Mendonca, Daniela [Universidade Catolica de Brasilia, Pos-Graduacao em Ciencias Genomicas e Biotecnologia, SGAN Quadra 916, Modulo B, Av. W5 Norte 70.790-160-Asa Norte Brasilia/DF (Brazil) and Bone Biology and Implant Therapy Laboratory, Department of Prosthodontics, University of North Carolina at Chapel Hill, 404 Brauer Hall, CB 7450, Chapel Hill, NC 27511 (United States); Pagotto Simoes, Luis Gustavo; Araujo, Andre Luis; Leite, Edson Roberto [Departmento de Quimica, Universidade Federal de Sao Carlos-UFSCAR, Rod. Washington Luiz, 13565-905 Sao Carlos, SP (Brazil); Golin, Alexsander Luiz [Departmento de Engenharia Mecanica, Faculdade de Engenharia Mecanica, Pontificia Universidade Catolica de Curitiba, Curitiba, PR (Brazil); Aragao, Francisco J.L. [Universidade Catolica de Brasilia, Pos-Graduacao em Ciencias Genomicas e Biotecnologia, SGAN Quadra 916, Modulo B, Av. W5 Norte 70.790-160-Asa Norte Brasilia/DF (Brazil); Embrapa Recursos Geneticos e Biotecnologia, Laboratorio de Introducao e Expressao de Genes, PqEB W5 Norte, 70770-900, Brasilia, DF (Brazil); Cooper, Lyndon F., E-mail: lyndon_cooper@dentistry.unc.edu [Bone Biology and Implant Therapy Laboratory, Department of Prosthodontics, University of North Carolina at Chapel Hill, 404 Brauer Hall, CB 7450, Chapel Hill, NC 27511 (United States)

    2011-12-01

    The aim of this study was to investigate the response of nanostructured implant surfaces at the level of osteoblast differentiation and its effects in bone-to-implant contact (BIC) and removal-torque values (RTV). CpTi grade IV implants (1.6 x 4.0 mm) were machined or machined and subsequently coated with an oxide solution. The surfaces were divided into: machined (M), titania-anatase (An), titania-rutile (Ru), and zirconia (Zr). Surfaces were examined by scanning electron microscopy, atomic force microscopy, and by X-ray microanalysis. Implants were inserted in rat tibia and harvested from 0 to 21 days for measurement of Alkaline Phosphatase, Bone Sialoprotein, Osteocalcin, Osteopontin, and RUNX-2 mRNA levels by real time PCR; from 0 to 56 days for RTV; and from 0 to 56 days for BIC. The roughness parameter (Sa) was compared by one-way ANOVA followed by Tukey Test. Comparison of Torque removal values and histomorphometric measurements on implants in vivo was performed by Kruskal-Wallis test and the significance level for all statistical analyses was set at p {<=} 0.05. mRNA levels on all nanostructured surfaces were increased compared to M. At 56 days, the mean RTV in Ncm was 11.6 {+-} 2.5, 11.3 {+-} 2.4, 11.1 {+-} 3.5, 9.7 {+-} 1.4 for An, Ru, Zr, and M, respectively. Higher BIC (%) was measured for all the nanostructured surfaces versus M at 21 and 56 days (p < 0.05). Nanostructured topographic features composed of TiO{sub 2} or ZrO{sub 2} applied to machined cpTi implant promoted greater mesenchymal stem cell commitment to the osteoblast phenotype and associated increased BIC and physical association with bone. Highlights: {yields} Nanostructured surfaces using a sol-gel technique coated cpTi with TiO{sub 2} or ZrO{sub 2}. {yields} Evaluated molecular and mechanical effect of nanofeatures in vivo in rat tibiae. {yields} Nanofeatures improved the differentiation of rat MSCs into osteoblasts. {yields} Nanofeatures improved increased bone-to-implant contact and

  8. Nanostructured implant surface effect on osteoblast gene expression and bone-to-implant contact in vivo

    International Nuclear Information System (INIS)

    Mendonca, Gustavo; Baccelli Silveira Mendonca, Daniela; Pagotto Simoes, Luis Gustavo; Araujo, Andre Luis; Leite, Edson Roberto; Golin, Alexsander Luiz; Aragao, Francisco J.L.; Cooper, Lyndon F.

    2011-01-01

    The aim of this study was to investigate the response of nanostructured implant surfaces at the level of osteoblast differentiation and its effects in bone-to-implant contact (BIC) and removal-torque values (RTV). CpTi grade IV implants (1.6 x 4.0 mm) were machined or machined and subsequently coated with an oxide solution. The surfaces were divided into: machined (M), titania-anatase (An), titania-rutile (Ru), and zirconia (Zr). Surfaces were examined by scanning electron microscopy, atomic force microscopy, and by X-ray microanalysis. Implants were inserted in rat tibia and harvested from 0 to 21 days for measurement of Alkaline Phosphatase, Bone Sialoprotein, Osteocalcin, Osteopontin, and RUNX-2 mRNA levels by real time PCR; from 0 to 56 days for RTV; and from 0 to 56 days for BIC. The roughness parameter (Sa) was compared by one-way ANOVA followed by Tukey Test. Comparison of Torque removal values and histomorphometric measurements on implants in vivo was performed by Kruskal-Wallis test and the significance level for all statistical analyses was set at p ≤ 0.05. mRNA levels on all nanostructured surfaces were increased compared to M. At 56 days, the mean RTV in Ncm was 11.6 ± 2.5, 11.3 ± 2.4, 11.1 ± 3.5, 9.7 ± 1.4 for An, Ru, Zr, and M, respectively. Higher BIC (%) was measured for all the nanostructured surfaces versus M at 21 and 56 days (p 2 or ZrO 2 applied to machined cpTi implant promoted greater mesenchymal stem cell commitment to the osteoblast phenotype and associated increased BIC and physical association with bone. Highlights: → Nanostructured surfaces using a sol-gel technique coated cpTi with TiO 2 or ZrO 2 . → Evaluated molecular and mechanical effect of nanofeatures in vivo in rat tibiae. → Nanofeatures improved the differentiation of rat MSCs into osteoblasts. → Nanofeatures improved increased bone-to-implant contact and removal torque values. → TiO 2 or ZrO 2 nanofeatures improved the biological response of machined titanium.

  9. Solving intraocular lens-related pigment dispersion syndrome with repositioning of primary sulcus implanted single-piece IOL in the capsular bag.

    Science.gov (United States)

    Kohnen, Thomas; Kook, Daniel

    2009-08-01

    We describe 2 cases of pigment dispersion syndrome (PDS) after uneventful phacoemulsification and implantation of a posterior chamber single-piece intraocular lens (IOL) with a sharp-edge design. In both cases, several days after IOL implantation, marked pigment dispersion was seen on the iris and in the trabecular meshwork, associated with an elevation in intraocular pressure (IOP). Thorough examination showed that the implanted IOL was in the ciliary sulcus. After surgical repositioning of both IOLs in the capsular bag, the pigment dispersion regressed and the IOP returned to normal limits. The 2 cases suggest that particularly in PDS patients, an IOL with an anterior sharp-edge design should be implanted in the capsular bag. Implantation in the ciliary sulcus should be avoided.

  10. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to replace the natural lens of an eye. (b) Classification. Class III. (c) Date PMA or notice of completion of a...

  11. Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis.

    Science.gov (United States)

    Liu, Hong-Ting; Zhou, Zhou; Luo, Wu-Qiang; He, Wen-Jing; Agbedia, Owhofasa; Wang, Jiang-Xia; Huang, Jian-Zhong; Gao, Xin; Kong, Min; Li, Min; Li, Li

    2018-01-01

    To compare the optical quality after implantation of implantable collamer lens (ICL) and wavefront-guided laser in situ keratomileusis (WG-LASIK). The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index (OSI), the values of modulation transfer function (MTF) cutoff frequency, Strehl ratio, and the Optical Quality Analysis System (OQAS) values (OVs) were accessed. The higher order aberrations (HOAs) data including coma, trefoil, spherical, 2 nd astigmatism and tetrafoil were also obtained. For patients with pupil size LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent ( P LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively (Wilcoxon signed ranks test, P =0.000). None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mm-pupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2 nd astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05, -0.04±0.04, 0.03±0.01 respectively (Wilcoxon signed ranks test, all P LASIK group. ICL implantation has a less disturbance to optical quality than WG-LASIK. The OQAS is a valuable complementary measurement to the wavefront aberrometers in evaluating the optical quality.

  12. Early lens extraction with intraocular lens implantation for the treatment of primary angle closure glaucoma: an economic evaluation based on data from the EAGLE trial

    Science.gov (United States)

    Javanbakht, Mehdi; Azuara-Blanco, Augusto; Burr, Jennifer M; Ramsay, Craig; Cooper, David; Cochran, Claire; Norrie, John; Scotland, Graham

    2017-01-01

    Objective To investigate the cost-effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle closure glaucoma (PACG) compared to standard care. Design Cost-effectiveness analysis alongside a multicentre pragmatic two-arm randomised controlled trial. Patients were followed-up for 36 months, and data on health service usage and health state utility were collected and analysed within the trial time horizon. A Markov model was developed to extrapolate the results over a 5-year and 10-year time horizon. Setting 22 hospital eye services in the UK. Population Males and females aged 50 years or over with newly diagnosed PACG or primary angle closure (PAC). Interventions Lens extraction compared to standard care (ie, laser iridotomy followed by medical therapy and glaucoma surgery). Outcome measures Costs of primary and secondary healthcare usage (UK NHS perspective), quality-adjusted life years (QALYs) and the incremental cost-effectiveness ratio (ICER) for lens extraction versus standard care. Results The mean age of participants was 67.5 (8.42), 57.5% were women, 44.6% had both eyes eligible, 1.4% were of Asian ethnicity and 35.4% had PAC. The mean health service costs were higher in patients randomised to lens extraction: £2467 vs £1486. The mean adjusted QALYs were also higher with early lens extraction: 2.602 vs 2.533. The ICER for lens extraction versus standard care was £14 284 per QALY gained at three years. Modelling suggests that the ICER may drop to £7090 per QALY gained by 5 years and that lens extraction may be cost saving by 10 years. Our results are generally robust to changes in the key input parameters and assumptions. Conclusions We find that lens extraction has a 67–89% chance of being cost-effective at 3 years and that it may be cost saving by 10 years. Trial registration number ISRCTN44464607; Results. PMID:28087548

  13. Note: Laser ablation technique for electrically contacting a buried implant layer in single crystal diamond

    International Nuclear Information System (INIS)

    Ray, M. P.; Baldwin, J. W.; Butler, J. E.; Pate, B. B.; Feygelson, T. I.

    2011-01-01

    The creation of thin, buried, and electrically conducting layers within an otherwise insulating diamond by annealed ion implantation damage is well known. Establishing facile electrical contact to the shallow buried layer has been an unmet challenge. We demonstrate a new method, based on laser micro-machining (laser ablation), to make reliable electrical contact to a buried implant layer in diamond. Comparison is made to focused ion beam milling.

  14. In vitro evaluation of resonance frequency analysis values to different implant contact ratio and stiffness of surrounding material.

    Science.gov (United States)

    Kwak, Mu-Seung; Kim, Seok-Gyu

    2013-11-01

    The present study was aimed to evaluate the influence of implant contact ratio and stiffness of implant-surrounding materials on the resonance frequency analysis (RFA) values. Seventy resin blocks that had the different amounts (100, 50, 30, 15%) of resin-implant contact (RIC) were fabricated. Ten silicone putty blocks with 100% silicone-implant contact were also made. The implants with Ø5.0 mm × 13.0 mm were placed on eighty specimen blocks. The RFA value was measured on the transducer that was connected to each implant by Osstell Mentor. Kruskal-Wallis and Scheffe's tests (α=.05) were done for statistical analysis. The control resin group with 100% RIC had the highest RFA value of 83.9, which was significantly different only from the resin group with 15% RIC among the resin groups. The silicone putty group with 100% contact had the lowest RFA value of 36.6 and showed statistically significant differences from the resin groups. Within the limitations of this in vitro study, there was no significant difference in the RFA values among the resin groups with different RIC's except when the RIC difference was more than 85%. A significant increase in the RFA value was observed related to the increase in stiffness of material around implant.

  15. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  16. Dry Eye Treatment Based on Contact Lens Drug Delivery: A Review.

    Science.gov (United States)

    Guzman-Aranguez, Ana; Fonseca, Begoña; Carracedo, Gonzalo; Martin-Gil, Alba; Martinez-Aguila, Alejandro; Pintor, Jesús

    2016-09-01

    Dry eye disease affects a substantial segment of the word population with increasing frequency. It is a multifactorial disease of the ocular surface and tear film, which causes ocular discomfort, visual disturbances, and tear instability with potential damage to the cornea and conjunctiva. Because of its multifactorial etiology, the use of different pharmacological treatment for dry eye treatment has been proposed, which include anti-inflammatory molecules, lubricants or comfort agents, and secretagogues. However, in some cases these pharmacological approaches only relieve symptoms temporarily, and consequently, eye care professionals continue to have difficulties managing dry eye. To improve pharmacological therapy that allows a more efficient and long-term action, effective ocular drug delivery of the currently available drugs for dry eye treatment is required. Contact lenses are emerging as alternative ophthalmic drugs delivery systems that provide an increased residence time of the drug at the eye, thus leading to enhanced bioavailability and more convenient and efficacious therapy. In this article, we reviewed the different techniques used to prepare contact lens-based drug delivery systems and focused on articles that describe the delivery of compounds for dry eye treatment through contact lenses.

  17. Fungal endophthalmitis caused by Paecilomyces variotii, in an immunocompetent patient, following intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Anita K

    2010-01-01

    Full Text Available We report the case of a 70-year-old man who was admitted for anterior endophthalmitis following an intraocular lens implantation. He had developed a fluffy growth resembling a fungal mass on the iris of the right eye. The mass was removed and sent for fungal studies to our department. Direct microscopy revealed hyphae. Further studies helped identify the fungus to belong to genus Paecilomyces. This is a rare case of fungal endophthalmitis caused by Paecilomyces variotii in an immunocompetent person.

  18. Changes in the accommodation-convergence relationship after the Artisan phakic intraocular lens implantation for myopic patients.

    Science.gov (United States)

    Ryu, Ik Hee; Han, Jinu; Lee, Hyung Keun; Kim, Jin Kook; Han, Sueng-Han

    2014-04-01

    To evaluate the change of accommodation-convergence parameters after implantation of Artisan phakic intraocular lens (PIOL). Prospective study for the patients with the Artisan PIOL implantation was performed. A total of 37 patients (3 males and 34 females) enrolled the study. Preoperatively, convergence amplitude, the stimulus accommodative convergence per unit of accommodation (AC/A) ratio and the near point of convergence (NPC) were evaluated. After the Artisan PIOL implantation, the identical evaluations were repeated at 1 week, 1, 3, and 6 months after the surgery. Mean age was 24.3 ± 4.8 years old, and preoperative refractive error was -8.92 ± 4.13 diopters (D). After the implantation, mean refractive errors significantly decreased to within ±1.00 D, and noticeable complications were not found. The convergence amplitude and the stimulus AC/A ratio increased 1 month after the surgery, but progressively stabilized afterward to near preoperative values. NPC didn't show any significant change over follow-up period up to 6 months. These results regarding implantation of the Artisan PIOL revealed the increase of accommodation-convergence relationship within first 1 month after the surgery, but progressive stabilization was noted during follow-up periods.

  19. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

    Science.gov (United States)

    Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin

    2015-03-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (pimplants using micro-CT analysis using a region-based segmentation method.

  20. Implantation of iris-claw Artisan intraocular lens for aphakia in Fuchs′ heterochromic iridocyclitis

    Directory of Open Access Journals (Sweden)

    Ahmad Kheirkhah

    2014-01-01

    Full Text Available Implantation of iris-claw Artisan intraocular lens (IOL is a surgical option for correction of aphakia; however, these IOLs have not been used in eyes with uveitis including Fuchs′ heterochromic iridocyclitis (FHI due to possible risk of severe postoperative intraocular inflammation. In the case reported here, we secondarily implanted an Artisan IOL in a 28-year-old man with FHI who had aphakia with no capsular support due to a previous complicated cataract surgery. Enclavation was easily performed and no intraoperative complication was noted. Postoperative course was uneventful with no significant anterior chamber inflammation during 12 months of follow-up. Although there were few deposits on the IOL surface, the patient achieved a best-corrected visual acuity of 20/20 without developing glaucoma or other complications. Therefore, Artisan IOL may be considered for correction of aphakia in patients with FHI. However, studies on large number of patients are required to evaluate safety of the procedure.

  1. Accommodative intraocular lens versus standard monofocal intraocular lens implantation in cataract surgery.

    Science.gov (United States)

    Ong, Hon Shing; Evans, Jennifer R; Allan, Bruce D S

    2014-05-01

    Following cataract surgery and intraocular lens (IOL) implantation, loss of accommodation or postoperative presbyopia occurs and remains a challenge. Standard monofocal IOLs correct only distance vision; patients require spectacles for near vision. Accommodative IOLs have been designed to overcome loss of accommodation after cataract surgery. To define (a) the extent to which accommodative IOLs improve unaided near visual function, in comparison with monofocal IOLs; (b) the extent of compromise to unaided distance visual acuity; c) whether a higher rate of additional complications is associated the use of accommodative IOLs. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 9), Ovid MEDLINE, Ovid MEDLINE in-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily Update, Ovid OLDMEDLINE (January 1946 to October 2013), EMBASE (January 1980 to October 2013), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to October 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrial.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 10 October 2013. We include randomised controlled trials (RCTs) which compared implantation of accommodative IOLs to implantation of monofocal IOLs in cataract surgery. Two authors independently screened search results, assessed risk of bias and extracted data. All included trials used the 1CU accommodative IOL (HumanOptics, Erlangen, Germany) for their intervention group. One trial had an additional arm with the AT-45 Crystalens accommodative IOL (Eyeonics Vision). We performed a separate analysis comparing 1CU and AT-45 IOL. We included four RCTs, including 229 participants (256 eyes

  2. Microbial contamination of contact lenses, lens care solutions, and their accessories: a literature review.

    Science.gov (United States)

    Szczotka-Flynn, Loretta B; Pearlman, Eric; Ghannoum, Mahmoud

    2010-03-01

    A contact lens (CL) can act as a vector for microorganisms to adhere to and transfer to the ocular surface. Commensal microorganisms that uneventfully cohabitate on lid margins and conjunctivae and potential pathogens that are found transiently on the ocular surface can inoculate CLs in vivo. In the presence of reduced tissue resistance, these resident microorganisms or transient pathogens can invade and colonize the cornea or conjunctiva to produce inflammation or infection. The literature was reviewed and used to summarize the findings over the last 30 years on the identification, enumeration, and classification of microorganisms adherent to CLs and their accessories during the course of normal wear and to hypothesize the role that these microorganisms play in CL infection and inflammation. Lens handling greatly increases the incidence of lens contamination, and the ocular surface has a tremendous ability to destroy organisms. However, even when removed aseptically from the eye, more than half of lenses are found to harbor microorganisms, almost exclusively bacteria. Coagulase-negative Staphylococci are most commonly cultured from worn lenses; however, approximately 10% of lenses harbor Gram-negative and highly pathogenic species, even in asymptomatic subjects. In storage cases, the incidence of positive microbial bioburden is also typically greater than 50%. All types of care solutions can become contaminated, including up to 30% of preserved products. The process of CL-related microbial keratitis and inflammation is thought to be preceded by the presence or transfer or both of microorganisms from the lens to the ocular surface. Thus, this detailed understanding of lens-related bioburden is important in the understanding of factors associated with infectious and inflammatory complications. Promising mechanisms to prevent bacterial colonization on lenses and lens cases are forthcoming, which may decrease the incidence of microbially driven CL complications.

  3. Magnetic attachment for implant overdentures: influence of contact relationship with the denture base on stability and bending strain.

    Science.gov (United States)

    Yang, Tsung-Chieh; Maeda, Yoshinobu; Gonda, Tomoya; Wada, Masahiro

    2013-01-01

    This study evaluated how the contact height between the magnetic attachment and denture base influences stability and bending strain. An implant modified with strain gauges and a magnetic attachment mounted in an acrylic resin block were used to characterize systems with varying degrees or heights of contact with the abutment. Bending strain under lateral loading increased significantly as the contact height decreased. In the no contact and resilient contact groups, magnetic assemblies separated at reduced bending strain in all loading conditions. The contact height of the magnetic attachment influenced the stability and the amount of bending strain on the implant.

  4. The Correlation between Daily Lens Wear Duration and Dry Eye Syndrome.

    Science.gov (United States)

    Lubis, Rodiah Rahmawaty; Gultom, Monica Tumiar Hanna

    2018-05-20

    To analyze the correlation between the daily lens wear duration and dry eye syndrome. This study was an analytic cross sectional study using consecutive sampling conducted among the students in Economy and Bussiness Faculty and Faculty of Humanities in University of Sumatera Utara aged between 17 to 23 that wore contact lens continously for at least a year and 5 days a week. The symptoms were assessed using Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and interview about their contact lens comfort; eye drops usage, contact lens washing habit, daily circumstances, places to buy contact lens and personal experince in wearing contact lens. The questionnaire was completed by 53 students. All of them were female and wore softlens wearers. The mean duration of daily wear was 8.19 ± 2.20 hours. The most common symptom experienced was dry eye and the least symptom experienced was removing lens. The most frequent symptom experienced was closing eyes and the least frequent symptom experienced was removing lenses. This study used Exact Test as analysis statistic method. The result was p > 0.05 which means there is no correlation between daily lens wear duration and dry eye syndrome. This study showed that dry eye syndrome was not correlated with daily lens wear duration, but affected by many factors such as contact lens, lens care solution, eye drops usage and environment.

  5. [Slit lamp optical coherence tomography study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation].

    Science.gov (United States)

    Yan, Pi-song; Zhang, Zhen-ping; Lin, Hao-tian; Wu, Wen-jie; Bai, Ling

    2009-09-01

    To investigate quantitative changes of the anterior segment configuration after clear corneal incision phacoemulsification and foldable intraocular lens (IOL) implantation with slit-lamp-adapted optical coherence tomography (SL-OCT). In prospective consecutive case series, clear corneal incision phacoemulsification and foldable intraocular lens implantation were performed in 44 eyes of 40 patients. The changes of the anterior segment configuration were performed by SL-OCT before and 1 day, 1 week, 2 weeks and 1 month after surgery. SPSS 16.0 software was used to analyze statistical difference. For all patients, the central corneal thickness (CCT) and the incisional corneal thickness (ICT) increased significantly 1 day after surgery (CCT increased 99.59 microm, ICT increased 234.57 microm; P = 0.490). At 1 month, the CCT almost had returned to baseline, but the ICT had been thicker about 19.25 microm than baseline(P = 0.001). The measurements of ACD, AOD500, AOD750, TISA500, TISA750 also increased significantly 1 day after surgery. Although the ACD had no changes within 2 weeks (all P 0.05). The SL-OCT could impersonality and quantificationally evaluate the anterior segment changes induced by cataract surgery.

  6. Contrast visual acuity after multifocal intraocular lens implantation:aspheric versus spherical design

    Directory of Open Access Journals (Sweden)

    Jun-Hua Li

    2014-02-01

    Full Text Available AIM: To evaluate contrast visual acuity (CVA after implantation of an aspheric apodized diffractive intraocular lens (IOL or a spherical apodized diffractive IOL in cataract surgery.METHOD: This prospective randomized controlled study with a 12-month follow-up compared the results of cataract surgery with implantation of an aspheric AcrySof ReSTOR SN6AD3 IOL (30 eyes and a spherical AcrySof ReSTOR SN60D3 IOL (30 eyes. CVA with best distance correction was measured at 4 contrast levels (100%, 25%, 10% and 5% under 3 levels of chart luminance [250, 85 and 25 candelas per square meter (cd/m2] using a multi-functional visual acuity tester (MFVA-100.RESULTS:At 12 months after surgery, there were no statistically significant differences in 100% CVA and 25% CVA under 250cd/m2 (P100%=0.875 and P25%=0.057 and 85cd/m2 (P100%=0.198 and P25%=0.193 between the aspheric group and the spherical group. However, the 10% CVA and 5% CVA were significant better in aspheric group than spherical group under 250cd/m2 (P10%=0.042 and P5%=0.007 and 85cd/m2 (P10%=0.002 and P5%=0.039. Under the luminance level of 25cd/m2, no significant differences was found in the 100% CVA between the 2 group (P100%=0.245, while aspheric group had better visual acuity in the remaining 3 contracts (P25%=0.023, P10%=0.026 and P5%=0.002, respectively.CONCULSION:The aspheric AcrySof ReSTOR SN6AD3 IOL provided patients with better low-contrast visual acuity than the spherical AcrySof ReSTOR SN60D3 IOL.Keyword:cataract surgery; intraocular lens; contrast sensitivity; visual acuity

  7. Bacterial Colonization of Disposable Soft Contact Lenses Is Greater during Corneal Infiltrative Events than during Asymptomatic Extended Lens Wear

    OpenAIRE

    Sankaridurg, Padmaja R.; Sharma, Savitri; Willcox, Mark; Naduvilath, Thomas J.; Sweeney, Deborah F.; Holden, Brien A.; Rao, Gullapalli N.

    2000-01-01

    Microorganisms, especially gram-negative bacteria, are considered to play a role in the etiology of certain corneal infiltrative events (CIEs) observed during soft contact lens wear. This study explored the possibility of microbial colonization of soft contact lenses as a risk factor leading to CIEs. In a clinical trial conducted from March 1993 to January 1996, 330 subjects wore disposable soft contact lenses on a 6-night extended-wear and disposal schedule. During this period, 4,321 lenses ...

  8. Comparison of bone-implant contact and bone-implant volume between 2D-histological sections and 3D-SRµCT slices

    Directory of Open Access Journals (Sweden)

    R Bernhardt

    2012-04-01

    Full Text Available Histological imaging is still considered the gold standard for analysing bone formation around metallic implants. Generally, a limited number of histological sections per sample are used for the approximation of mean values of peri-implant bone formation. In this study we compared statistically the results of bone-implant contact (BIC and bone-implant volume (BIV obtained by histological sections, with those obtained by X-ray absorption images from synchrotron radiation micro-computed tomography (SRµCT using osseointegrated screw-shaped implants from a mini-pig study. Comparing the BIC results of 3-4 histological sections per implant sample with the appropriate 3-4 SRµCT slices showed a non-significant difference of 1.9 % (p = 0.703. The contact area assessed by the whole 3D information from the SRµCT measurement in comparison to the histomorphometric results showed a non-significant difference in BIC of 4.9 % (p = 0.171. The amount of the bone-implant volume in the histological sections and the appropriate SRµCT slices showed a non-significant difference by only 1.4 % (p = 0.736 and also remains non-significant with 2.6 % (p = 0.323 using the volumetric SRµCT information. We conclude that for a clinical evaluation of implant osseointegration with histological imaging at least 3-4 sections per sample are sufficient to represent the BIC or BIV for a sample. Due to the fact that in this study we have found a significant intra-sample variation in BIC of up to ± 35 % the selection of only one or two histological sections per sample may strongly influence the determined BIC.

  9. Effect of contact lens wear and a near task on tear film break-up.

    Science.gov (United States)

    Jansen, Meredith E; Begley, Carolyn G; Himebaugh, Nikole H; Port, Nicholas L

    2010-05-01

    To study the effect of extrinsic controls on blinking by examining blink parameters and tear stability among adapted soft contact lens (CL) wearers performing tasks that require varying amounts of visual concentration. The Demographic Questionnaire, Contact Lens Dry Eye Questionnaire, and Current Symptoms Questionnaire were completed by 15 adapted soft CL wearers (nine females). Three 55 s simultaneous measurements of tear film stability via retroillumination and blinking were obtained with a slit-lamp biomicroscope and 200 Hz video camera while subjects listened to music and played a video game with and without their habitual CLs. Interblink interval (IBI) and blink amplitude (BA) were calculated. The area of break-up (AB) was calculated for the retroillumination image before each blink. The Current Symptoms Questionnaire was completed four times throughout testing. With the game compared to music, IBI was significantly longer and BA significantly decreased without CLs (p or = 0.5579, p or = 0.6262, p or = 0.5064, p film instability increased. Blinking frequency also increased, but it remained high when subjects played the game, and symptoms of ocular irritation increased. This suggests that wearing soft CLs, even when fully adapted, provides enough extrinsic ocular surface stimulation to override internal controls and affect blink parameters.

  10. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji [Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2015-03-15

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  11. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    International Nuclear Information System (INIS)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji

    2015-01-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  12. Corneal injection track:an unusual complication of intraocular lens implantation and review

    Directory of Open Access Journals (Sweden)

    Julie Y.C. Lok

    2015-06-01

    Full Text Available Phacoemulsification is the main gold standard for cataract operation in the developed world together with foldable intraocular lens (IOL implantation by injection, allowing for stable wound construction and less postoperative astigmatism. It is a safe procedure with high success rate with the advancement in machines, improvement of IOL injection systems and further maturation of surgeons’ techniques. Despite the large number of operations performed every day, foldable IOL injection leading to an intra-stromal corneal track is a very rare complication. We report a case of this unusual finding in a 70-year-old gentleman who has undergone cataract operation in November 2011 in our hospital and will review on the complications related to foldable IOL injection.

  13. Correction of High Astigmatism after Penetrating Keratoplasty with Toric Multifocal Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-07-01

    Full Text Available After penetrating keratoplasty (PK, high astigmatism is often induced, being frequently about 4–6 dpt. According to the entity and typology of astigmatism, different methods of correction can be used. Selective suture removal, relaxing incisions, wedge resections, compression sutures, photorefractive keratectomy, and laser-assisted in situ keratomileusis can reduce corneal astigmatism and ametropia, but meanwhile they can cause a reduction in the corneal integrity and cause an over- or undercorrection. In case of moderate-to-high regular astigmatisms, the authors propose a toric multifocal intraocular lens (IOL implantation to preserve the corneal integrity (especially in PK after herpetic corneal leukoma keratitis. We evaluated a 45-year-old patient who at the age of 30 was subjected to PK in his left eye due to corneal leukoma herpetic keratitis, which led to high astigmatism (7.50 dpt cyl. 5°. The patient was subjected to phacoemulsification and customized toric multifocal IOL implantation in his left eye. The correction of PK-induced residual astigmatism with a toric IOL implantation is an excellent choice but has to be evaluated in relation to patient age, corneal integrity, longevity graft, and surgical risk. It seems to be a well-tolerated therapeutic choice and with good results.

  14. A contact lens with integrated telecommunication circuit and sensors for wireless and continuous tear glucose monitoring

    International Nuclear Information System (INIS)

    Yao, H; Liao, Y; Lingley, A R; Afanasiev, A; Lähdesmäki, I; Otis, B P; Parviz, B A

    2012-01-01

    We present an integrated functional contact lens, composed of a differential glucose sensor module, metal interconnects, sensor read-out circuit, antenna and telecommunication circuit, to monitor tear glucose levels wirelessly, continuously and non-invasively. The electrochemical differential sensor module is based on immobilization of activated and de-activated glucose oxidase. We characterized the sensor on a model polymer eye and determined that it showed good repeatability, molecular interference rejection and linearity in the range of 0–2 mM glucose, covering normal tear glucose concentrations (0.1–0.6 mM). We also report the temperature, ageing and protein-fouling sensitivity of the sensor. We report the design and implementation of a low-power (3 µW) sensor read-out and telecommunication circuit to deliver wireless power and transmit data for the sensor module. Using this small chip (0.36 mm 2 ), we produced an integrated contact lens with sensors and demonstrated wireless operation of the system and glucose read-out over the distance of several centimeters. (paper)

  15. Adaptação de lentes de contato após cirurgia refrativa Contact lens fitting after refractive surgery

    Directory of Open Access Journals (Sweden)

    Adimara da Candelária Renesto

    2005-02-01

    Full Text Available OBJETIVO: Avaliar a adaptação e o uso de lente de contato em pacientes que foram submetidos à cirurgia refrativa. MÉTODOS: Foi realizado estudo retrospectivo de 53 pacientes submetidos à cirurgia refrativa, que posteriormente passaram a usar lente de contato, no período de 1999 a 2003. Foram avaliados a ametropia prévia, tipo de cirurgia realizada, refração pós-cirúrgica, equivalente esférico pós-cirurgia, ceratometria pós-operatória, curva base da lente adaptada, tipo de lente de contato adaptada, acuidade visual com óculos no pós-operatório, acuidade visual final com lente de contato, complicações e motivo da interrupção do uso. O tempo de seguimento variou de 1 mês a 84 meses (média de 42,5 meses. RESULTADOS: Dos 53 pacientes analisados, 19 pacientes foram submetidos a LASIK (Laser Assisted in Situ Keratomileusis, 29 pacientes foram submetidos à RK (ceratotomia radial, 4 pacientes foram submetidos a PRK (ceratectomia fotoablativa e em um paciente não foi possível obter o tipo de cirurgia realizado. Em 61,29% dos pacientes, (57 olhos de um total de 93, foram adaptadas lentes de contato rígidas gás-permeáveis esféricas. Houve melhora da acuidade visual em 60,21% dos casos (AV>20/40, com poucas complicações. CONCLUSÃO: Devido ao número cada vez maior de cirurgias refrativas realizadas, espera-se que aumente o número de pacientes insatisfeitos com o resultado no pós-operatório e para os quais o uso de lentes de contato venha a ser a melhor opção. A adaptação de lentes de contato pós-cirurgia refrativa exige conhecimento e dedicação e em geral tem bons resultados principalmente pela melhora da acuidade visual.PURPOSE: To evaluate the fitting and use of contact lens in patients submitted to refractive surgery. METHODS: This was a retrospective study in 53 patients submitted to refractive surgery who later started to use contact lens, from 1999 to 2003. The parameters were: previous ametropia, refractive

  16. Influence of corneal asphericity on the refractive outcome of intraocular lens implantation in cataract surgery.

    Science.gov (United States)

    Savini, Giacomo; Hoffer, Kenneth J; Barboni, Piero

    2015-04-01

    To evaluate the possible influence of anterior corneal surface asphericity on the refractive outcomes in eyes having intraocular lens (IOL) implantation after cataract surgery. Fondazione G.B. Bietti IRCCS, Rome, Italy. Retrospective comparative case series. Intraocular lens power was calculated using the Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Asphericity (Q-value) was measured at 8.0 mm with a Placido-disk corneal topographer (Keratron), a rotating Scheimpflug camera (Pentacam), and a rotating Scheimpflug camera combined with Placido-disk corneal topography (Sirius). The relationship between the error in refraction prediction (ie, difference between expected refraction and refraction measured 1 month after surgery) and the Q-value was assessed by linear regression. The same IOL model (Acrysof SA60AT) was implanted in 115 eyes of 115 consecutive patients. Regression analysis showed a statistically significant relationship between the error in refraction prediction and the Q-value with all formulas and all devices. In all cases, a more negative Q-value (prolate cornea) was associated with a myopic outcome, whereas a more positive Q-value (oblate cornea) was associated with a hyperopic outcome. The highest coefficient of determination was detected between the Hoffer Q formula and the Placido-disk corneal topographer (R(2) = 0.2630), for which the error in refraction prediction (y) was related to the Q-value (x) according to the formula y = -0.2641 + 1.4589 × x. Corneal asphericity influences the refractive outcomes of IOL implantation and should be taken into consideration when using third-generation IOL power formulas. Dr. Hoffer receives book royalties from Slack, Inc., Thorofare, New Jersey, and formula royalties from all manufacturers using the Hoffer Q formula. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Comparative Study of Antibacterial and Antifungal Effects of Rigid Gas Permeable Contact Lens Disinfecting Solutions

    OpenAIRE

    Kuzman, Tomislav; Barišić Kutija, Marija; Kordić, Rajko; Popović Suić, Smiljka; Jandroković, Sonja; Škegro, Ivan; Pokupec, Rajko

    2013-01-01

    The aim of this study was to compare antimicrobial efficacy of rigid contact lens disinfecting solutions. We tested five commercially available solutions: Unique pH (Alcon Laboratories), Boston Advance (Polymer Technology Corp.), Nitilens Conditioner GP (Avizor), Total Care (AMO), Boston Simplus (Bausch&Lomb). Their efficacy to disinfect saline solution experimentally contaminated with American Type Culture Collection (ATCC): Staphylococcus aureus (ATCC 25923), Escherichia coli (ATCC 25922...

  18. Review on the refractive treatment methods of aphakia

    Directory of Open Access Journals (Sweden)

    Xiao-Yan Deng

    2015-06-01

    Full Text Available The refractive treatment methods of aphakia include corrective glasses, contact lens correction and intraocular lens(IOLimplantation. It magnifies images highly and limits vision field with corrective glasses. For infant aphakia corrective glasses are more likely to be chosen because their eyes are still unable to tolerate IOL implantation in the developmental stage. With low magnification of images, contact lens includes soft contact lens and rigid contact lens. The former is rarely used because it is prone to ocular lesions due to its poor oxygen permeability. The latter is widely used due to its good oxygen permeability especially suitable for the eyes of irregular astigmatism or iris missing due to trauma. At present, the most commonly used in clinical work is IOL implantation. The eye of IOL may avoid anisometropia, aberrations and so on because of more physiological anatomy. According to the IOL implantation site, it is divided into the anterior chamber IOL implantation and the posterior chamber IOL implantation. The anterior chamber IOL implantation is divided into angle fixed IOL implantation and iris fixed IOL implantation. The posterior chamber IOL implantation is divided into secondary in-the-bag IOL implantation, the ciliary sulcus IOL implantation and transscleral suture fixed IOL implantation.

  19. A Conjunctival Mass in the Deep Superior Fornix After a Long Retained Hard Contact Lens in a Patient With Keloids

    NARCIS (Netherlands)

    Zola, Enrica; van der Meulen, Ivanka J. E.; Lapid-Gortzak, Ruth; van Vliet, J. Mj; Nieuwendaal, Carla P.

    2008-01-01

    Purpose: To report a case of an upper eyelid mass induced by a rigid contact lens retained for more than 3 years in the eye of a patient with a general history of keloids and to provide a review of the literature on retained contact lenses. Methods: Case report. Results: A 45-year-old woman with an

  20. Common symptoms of Nepalese soft contact lens wearers: A pilot study.

    Science.gov (United States)

    Sapkota, Kishor; Martin, Raul; Franco, Sandra; Lira, Madalena

    2015-01-01

    To determine the common symptoms in current soft contact lens (CL) wearers and their association with other factors among Nepalese population. All the current CL wearers who started to wear soft CL in Nepal Eye Hospital between July 2007 and June 2012 were invited for the participation. Frequency of the ten most common symptoms, divided into never, occasionally, frequently and consistent were recorded. Association between degree of symptoms with other factors, e.g. age, gender, profession, cigarette smoking, ethnicity, level of education and duration and wearing modality of CL wear were analyzed. Out of 129 subjects participated in this study, 67% were female; the mean age of the subjects was 23.9±4.3 years. Ninety seven percent of them had at least one symptom occasionally or frequently or consistently. Discomfort was found in 88.4% of the total subjects. Other common symptoms were foreign body sensation in 73.6%, redness in 65.9%, reduced wearing time in 63.6% and dryness in 62.8%. Symptoms were found occasionally in the majority of subjects. Degree of symptoms was not associated with age, gender, profession, education status, ethnicity of subjects and duration or modality of lens wear (p>0.05) but was positively associated with passive cigarette smoking (p<0.001). Almost all of the Nepalese soft CL wearers had some types of symptoms at least occasionally. Discomfort was the most common symptom. Degree of symptoms was associated with the passive smoking but not with other factors like age, sex, profession and duration of lens wear. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  1. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty.

    Science.gov (United States)

    Zafar, Andleeb; Aslanides, Ioannis M; Selimis, Vasileios; Tsoulnaras, Konstantinos I; Tabibian, David; Kymionis, George D

    2018-01-01

    We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye.

  2. Cionni ring and in-the-bag intraocular lens implantation for subluxated lenses: a prospective case series.

    Science.gov (United States)

    Vasavada, Abhay R; Praveen, Mamidipudi R; Vasavada, Viraj A; Yeh, Ru-Yin; Srivastava, Samaresh; Koul, Archana; Trivedi, Rupal H

    2012-06-01

    To report the intraoperative performance and postoperative outcomes of the Cionni-modified capsule tension ring (CTR) implantation in eyes with subluxated lenses. Prospective, observational case series. This study was carried out at Iladevi Cataract & IOL Research Centre, Ahmedabad, India. The study population comprised 41 eyes with subluxated lenses that underwent lens extraction, capsular bag fixation with modified CTR, and in-the-bag single-piece AcrySof intraocular lens (IOL) implantation. Main outcome measures were intraoperative performance and postoperative best-corrected visual acuity (BCVA), IOL centration, and complications. The mean age was 29.46 ± 16.16 years (3-68 years). Mean extent of subluxation was 6.1 ± 1.0 clock hours. Preoperatively, vitreous was detected in the anterior chambers of 5 eyes (12.2%). Two-port anterior chamber vitrectomy was performed in 2 eyes. Mean follow-up was 45.8 ± 2.9 months. Mean preoperative BCVA was 0.66 ± 0.22 logMAR (35 eyes). Mean postoperative BCVA at final follow-up was 0.33 ± 0.21 logMAR (41 eyes) (P IOL decentration was noted and repositioning was required in 2 eyes. Posterior capsule opacification developed in 14 eyes (34.2%); 12 eyes (29.3%) required Nd:YAG capsulotomy. Other complications included cystoid macular edema in 1 eye (2.4%), posterior synechiae in 1 eye (2.4%), and retinal detachment in 1 eye (2.4%). In-the-bag implantation of a Cionni-modified CTR with IOL appears to be a safe option in eyes with subluxated cataract, ensuring a stable IOL with few complications. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation - Our experience.

    Science.gov (United States)

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Cataract services, Shroff Eye Centre, New Delhi, India. Case series. This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was -0.04 (SD = 0.76). We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.

  4. Tear exchange and contact lenses: a review.

    Science.gov (United States)

    Muntz, Alex; Subbaraman, Lakshman N; Sorbara, Luigina; Jones, Lyndon

    2015-01-01

    Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  5. [Clinical results after implantation of a new segmental refractive multifocal intraocular lens].

    Science.gov (United States)

    Thomas, B C; Auffarth, G U; Philips, R; Novák, J; Blazek, J; Adamkova, H; Rabsilber, T M

    2013-11-01

    The aim of the study was a clinical evaluation of an intraocular lens (IOL) with a segmental multifocal optic design and near addition of + 3.0 D as part of a CE approval study. In a multicenter study the LENTIS Mplus LS-312 MF IOL (Oculentis) was implanted in 134 eyes of 79 patients with a mean age of 68 ± 12 years. The multifocality is achieved by implementation of a distance part and a segmented near sector. Three months after surgery, uncorrected and best corrected distance visual acuity (UCDVA and BCDVA, respectively), near visual acuity (UCNVA and BCNVA, respectively), contrast vision and patient satisfaction (questionnaire) were evaluated. The IOLs were implanted uneventfully either unilaterally or bilaterally and 3 months postoperatively (n = 86 eyes) the following mean visual acuities were obtained (logMAR): UCDVA = 0.05, BCDVA = - 0.01, UCNVA = 0.09 and BCNVA = 0.02. Contrast sensitivity (n = 25 eyes) was within normal limits. Of the 66 questioned patients 10.6% spontaneously reported halos and 3% glare. This new innovative multifocal IOL concept showed very good functional results as well as high patient satisfaction.

  6. Posterior chamber lens implantation with scleral fixation in children with traumatic cataract.

    Science.gov (United States)

    Caca, Ihsan; Sahin, Alparslan; Ari, Seyhmus; Alakus, Fuat

    2011-01-01

    To evaluate the outcomes of posterior chamber lens implantation with scleral fixation (SF-PCIOL) in children with traumatic cataract. Twenty-four eyes of 24 cases were included. All patients had corneal or corneoscleral lacerations that were primarily repaired. Traumatic cataract subsequently developed and SF-PCIOL was performed due to insufficient posterior capsule support. The average age of the patients was 5.8 years (range: 4 to 10 years). All cases had SF-PCIOL implanted via internal route using triangular double scleral flaps made of 9-0 polypropylene after a complete anterior vitrectomy. Average follow-up was 14.6 ± 4.3 months (range: 11 to 18 months). Visual acuity was increased at the last visit in 23 (96%) patients. Common postoperative complications were fibrinous reaction in 6 (25%) patients, transient intraocular pressure increase in 4 (17%) patients, membrane formation requiring removal in 1 (4%) patient, transient intraocular hemorrhage as vitreous hemorrhage in 1 (4%) patient, and retinal detachment in 1 (4%) patient after the postoperative second month. SF-PCIOL is an effective and reliable method in patients with pediatric traumatic cataract who had insufficient posterior capsule support. Copyright 2011, SLACK Incorporated.

  7. Antimicrobial Efficacy of Multipurpose Disinfecting Solutions in the Presence of Contact Lenses and Lens Cases.

    Science.gov (United States)

    Gabriel, Manal M; McAnally, Cindy; Bartell, John

    2018-03-01

    The aim of this study was to use antimicrobial efficacy endpoint methodology to determine compatibility of multipurpose disinfecting solutions (MPSs), lens cases, and hydrogel lenses for disinfection (AEEMC) against International Organization for Standardization (ISO)-specified microorganisms and clinical ocular isolates of Stenotrophomonas maltophilia. Six MPSs (PQ/Aldox 1, 2, and 3; PQ/Alexidine; PQ/PHMB; and PHMB) were challenged against ISO-specified microorganisms and S. maltophilia using the AEEMC test. AEEMC tests were performed with and without balafilcon A, etafilcon A, and senofilcon A lenses in lens cases with organic soil. Exposure times included disinfection time (DT) and 24 hr. Additionally, all six MPSs were challenged with two strains of S. maltophilia, based on the ISO Stand-alone test. The efficacy against bacteria for PQ/Aldox and PQ/Alexidine MPSs was not diminished by the presence of lenses. The efficacy of PQ/PHMB and PHMB MPSs against Serratia marcescens was significantly reduced compared with the no-lens control at DT for at least one lens type. The PHMB MPS with lenses present also demonstrated reduced efficacy against Staphylococcus aureus at DT versus the control. PQ/Aldox MPSs retained activity against Fusarium solani with lenses present; however, all other test MPSs demonstrated reduced F. solani efficacy at DT with lenses present. With lenses, all MPSs showed reduced efficacy against Candida albicans. AEEMC antimicrobial efficacy test results vary based on challenge microorganism, contact lenses, and MPS biocide systems. This study highlights the importance of evaluating MPSs for compatibility with lenses and lens cases.

  8. Factors associated with strabismus after cataract extraction and primary intraocular lens implantation in congenital cataracts

    Directory of Open Access Journals (Sweden)

    Soo Jung Lee

    2014-06-01

    Full Text Available AIM: To evaluate factors associated with the development of strabismus after cataract extraction and primary intraocular lens implantation.METHODS: The medical records of 122 patients, aged 1.5mo to 9y, who had undergone cataract extraction with primary intraocular lens implantation between January 1993 and August 2011 were reviewed. Fourteen patients (17 eyes with strabismus before cataract surgery were excluded. Patients were divided into those with congenital bilateral cataracts (64 patients, 128 eyes and those with unilateral cataracts (44 patients, 44 eyes. The associations between the development of strabismus and age at cataract surgery, pre- and post-cataract extraction corrected distance visual acuity (CDVA, interocular CDVA difference, nystagmus, surgical method, and secondary cataract were evaluated.RESULTS: Factors significantly associated with the development of strabismus included age at cataract surgery (≤1y, preoperative mean CDVA ≤20/100, presence of nystagmus in the bilateral cataract group and postoperative interocular CDVA difference >20/70 in the unilateral group. Postoperative CDVA ≤20/100 and preservation of posterior capsule, and presence of secondary cataract were significant factors in both groups.CONCLUSION: Children with congenital cataracts should be monitored carefully after cataract surgery for the development of strabismus, especially when they underwent surgery at age ≤1y, and they have nystagmus, large postoperative interocular CDVA difference, poor preoperative and postoperative CDVA, preservation of the posterior capsule, or secondary cataract.

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... the United States. All contact lenses are medical devices that require a prescription and proper fitting by an eye-care professional. Retailers that sell contacts without a ...

  10. Non-invasive pre-lens tear film assessment with high-speed videokeratoscopy.

    Science.gov (United States)

    Llorens-Quintana, Clara; Mousavi, Maryam; Szczesna-Iskander, Dorota; Iskander, D Robert

    2018-02-01

    To evaluate the effect of two types of daily contact lenses (delefilcon A and omafilcon A) on the tear film and establish whether it is dependent on pre-corneal tear film characteristics using a new method to analyse high-speed videokeratoscopy recordings, as well as to determine the sensitivity of the method in differentiating between contact lens materials on eye. High-speed videokeratoscopy recordings were analysed using a custom made automated algorithm based on a fractal dimension approach that provides a set of parameters directly related to tear film stability. Fifty-four subjects participated in the study. Baseline measurements, in suppressed and natural blinking conditions, were taken before subjects were fitted with two different daily contact lenses and after four hours of contact lens wear. The method for analysing the stability of the tear film provides alternative parameters to the non-invasive break up time to assess the quality of the pre-corneal and pre-lens tear film. Both contact lenses significantly decreased the quality of the tear film in suppressed and natural blinking conditions (pfilm characteristics were not correlated with the decrease in pre-lens tear film quality. High-speed videokeratoscopy equipped with an automated method to analyse the dynamics of the tear film is able to distinguish between contact lens materials in vivo. Incorporating the assessment of pre-lens tear film to the clinical practice could aid improving contact lens fitting and understand contact lens comfort. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  11. Usefullness of three-dimensional templating software to quantify the contact state between implant and femur in total hip arthroplasty.

    Science.gov (United States)

    Inoue, Daisuke; Kabata, Tamon; Maeda, Toru; Kajino, Yoshitomo; Fujita, Kenji; Hasegawa, Kazuhiro; Yamamoto, Takashi; Takagi, Tomoharu; Ohmori, Takaaki; Tsuchiya, Hiroyuki

    2015-12-01

    It would be ideal if surgeons could precisely confirm whether the planned femoral component achieves the best fit and fill of implant and femur. However, the cortico-cancellous interfaces can be difficult to standardize using plain radiography, and therefore, determining the contact state is a subjective decision by the examiner. Few reports have described the use of CT-based three-dimensional templating software to quantify the contact state of stem and femur in detail. The purpose of this study was to use three-dimensional templating software to quantify the implant-femur contact state and develop a technique to analyze the initial fixation pattern of a cementless femoral stem. We conducted a retrospective review of 55 hips in 53 patients using a short proximal fit-and-fill anatomical stem (APS Natural-Hip™ System). All femurs were examined by density mapping which can visualize and digitize the contact state. We evaluated the contact state of implant and femur by using density mapping. The varus group (cases that had changed varus 2° by 3 months after surgery) consisted of 11 hips. The varus group showed no significant difference with regard to cortical contact in the proximal medial portion (Gruen 7), but the contact area in the distal portion (Gruen 3 and Gruen 5) was significantly lower than that of non-varus group. Density mapping showed that the stem only has to be press-fit to the medial calcar, but also must fill the distal portion of the implant in order to achieve the ideal contact state. Our results indicated that quantifying the contact state of implant and femur by using density mapping is a useful technique to accurately analyze the fixation pattern of a cementless femoral stem.

  12. Implantação de lente intraocular com uma alça amputada: proposta para o tratamento cirúrgico da subluxação do cristalino Intraocular lens implantation with one loop haptic amputed: a new propose to the subluxation lens surgical treatment

    Directory of Open Access Journals (Sweden)

    Marcelo Ventura

    2010-04-01

    Full Text Available OBJETIVO: Avaliar os resultados pós-operatórios da subluxação congênita do cristalino, corrigida por uma nova abordagem cirúrgica. MÉTODOS: Foram estudados 21 olhos de 13 pacientes, portadores de subluxação não traumática do cristalino submetidos à cirurgia na Fundação Altino Ventura, no período de abril de 1999 a abril de 2004. A idade média foi de 8,7 ± 5,4 anos, e o tempo médio de seguimento foi 21,5 ± 19,3 meses. Os pacientes foram submetidos à facoaspiração, implante do anel endocapsular e lente intraocular (LIO. Uma das alças da LIO foi amputada e apoiada sobre o anel, no interior do saco capsular, centralizando a LIO. RESULTADOS: Houve melhora da acuidade visual (AV em todos os casos, e redução significante do equivalente esférico e componente esférico comparando-se a refração pré e pós-operatória (pPURPOSE: To evaluate the postoperative results of congenital lens subluxation corrected by a new technique. METHODS: Retrospective chart review of 21 eyes of 13 patients with no traumatic lens subluxation who underwent surgery in Altino Ventura Foundation from April, 1999 to April, 2004. The mean age was 8.7 ± 5.4 years old, and the mean follow-up period was 21.5 ± 19.3 months. Patients underwent phacoaspiration, endocapsular ring and intraocular lens (IOL implantation. The implanted IOL had one loop haptic excised and was supported above the ring, inside the capsular bag promoting intraocular lens centralization. RESULTS: Visual acuity improvement was observed in all cases. There was a significant reduction of the spherical equivalent and spherical component comparing the pre and postoperative refraction (p<0.01. There was no statistically significant difference between the pre and postoperative cylinder component (p=0.71. Posterior capsule opacification was a postoperative complication found in 71.4% of the cases. Early posterior capsulotomy was performed with no complications in these cases. CONCLUSION

  13. Colored Contact Lens Dangers

    Science.gov (United States)

    ... Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados ... truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non- ...

  14. Focusing on Contact Lens Safety

    Science.gov (United States)

    ... their practices. Decorative contacts (also called “costume,” colored,” “fashion,” or “plano” contacts). The FDA has often warned ... Lenses Decorative Contact Lenses Hydrogen Peroxide Solution Related Consumer Updates 'Colored' and Decorative Contact Lenses: A Prescription ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over-the-Counter Costume Contact Lenses Can ... was in severe pain and on medication for four weeks, and couldn't see well enough to ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ... wear costume contact lenses for Halloween or any time of year, follow these guidelines: Get an eye ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager ... the lenses. Never share contact lenses with another person. Get follow up exams with your eye care ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering ... Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados ... truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non- ...

  1. Adaptação de lente de contato gelatinosa especial para ceratocone Keratoconus special soft contact lens fitting

    Directory of Open Access Journals (Sweden)

    Ester Sakae Yamazaki

    2006-08-01

    Full Text Available OBJETIVO: Relatar a experiência inicial com o uso de lentes de contato gelatinosas especiais para ceratocone. MÉTODOS: Estudo retrospectivo de 80 olhos de 66 pacientes usuários de lentes de contato gelatinosas especial para ceratocone, no Setor de Lentes de Contato da UNIFESP e em clínicas particulares. Os pacientes foram classificados de acordo com o grau de gravidade da doença pela avaliação ceratométrica. Foram coletados os seguintes dados: idade, sexo, diagnóstico, ceratometria, acuidade visual com a lente, equivalente esférico (ES, curvatura da lente e indicação para o seu uso. RESULTADOS: Foram estudados 80 olhos de 66 pacientes usuários de lente gelatinosa para ceratocone. A média de idade foi de 29 anos, sendo 51,5% homens e 48,5% de mulheres. De acordo com os grupos: incipiente: 15,0%, moderado: 53,7%, avançado: 26,3%, grave: 5,0%. A maioria dos olhos estudados (91,25% apresentou acuidade visual melhor que 20/40 com a lente. Foram adaptadas 58% lentes de poder esférico (média de -5,45 dioptrias e 41% lentes com grau esferocilíndrico (variando de -0,50 a -5,00 dioptrias cilíndricas. A curva esférica mais utilizada foi de 7,6 mm (61% dos olhos. As principais razões para a escolha e adaptação desta lente foram devido à intolerância e ao padrão de adaptação insatisfatório com outras lentes. CONCLUSÃO: A lente gelatinosa para ceratocone pode ser usada em casos de difícil adaptação, como uma opção para melhorar o conforto e possibilitar a reabilitação visual em pacientes que não obtiveram alternativas a não ser algum procedimento cirúrgico.PURPOSE: To evaluate the fitting and use of a soft contact lens in keratoconic patients. METHODS: Retrospective study on 80 eyes of 66 patients, fitted with a special soft contact lens for keratoconus, at the Contact Lens Section of UNIFESP and private clinics. Keratoconus was classified according to degrees of disease severity by keratometric pattern. Age, gender

  2. Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis

    Directory of Open Access Journals (Sweden)

    Hong-Ting Liu

    2018-04-01

    Full Text Available AIM: To compare the optical quality after implantation of implantable collamer lens (ICL and wavefront-guided laser in situ keratomileusis (WG-LASIK. METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index (OSI, the values of modulation transfer function (MTF cutoff frequency, Strehl ratio, and the Optical Quality Analysis System (OQAS values (OVs were accessed. The higher order aberrations (HOAs data including coma, trefoil, spherical, 2nd astigmatism and tetrafoil were also obtained. For patients with pupil size <6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded. RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent (P< 0.001. After the ICL implantation, the OSI decreased slightly from 2.34±1.92 to 2.24±1.18 with no statistical significance (P=0.62. While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively (Wilcoxon signed ranks test, P=0.000. None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mm-pupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2nd astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05, -0.04±0.04, 0.03±0.01 respectively (Wilcoxon signed ranks test

  3. Anomalies in the prescribing of soft contact lens power.

    Science.gov (United States)

    Young, Graeme; Moody, Kurt; Sulley, Anna

    2009-01-01

    To determine the proportion of prescribed soft lenses rounded to the nearest half diopter and any variations from country to country and between lens types. Marketing data were obtained for soft lenses supplied during a 1-year period for lenses representing each of the following categories: mid-water hydrogel (MWH), silicone hydrogel, daily disposable, and toric silicone hydrogel (TSH). The data were analyzed for several countries/regions. Spherical lenses were analyzed in the range 1.00 to 5.75 D for plus and minus powers, and toric lenses in the range 0.50 to 5.75 D. This ensured a similar number of lenses in full or half diopter powers were compared with quarter and three-quarter diopter powers, and that there was no enforced rounding due to nonavailability of powers. By comparing the proportion of lenses from the 2 power groups, the proportion of lenses rounded to the nearest half diopter was estimated. It was assumed that half the difference between the totals of the 2 power groups represented those lenses dispensed to the nearest half diopter and, therefore, dispensed inaccurately; this was termed the "rounding rate" (RR). The power distribution curve for the sphere powers spiked in half diopter steps, illustrated a bias toward prescribing full and half diopter powers. With all lenses, the RR varied widely between countries. For the MWH, this ranged from 1.7% (Canada) to 11.6% (Iberia). The RRs were 2 to 3 times higher for plus than minus power lenses, however, this also varied by country. Overall, the RRs were lower for the silicone hydrogel and daily disposable contact lenses compared with the MWH, in particular for France and Iberia. The TSH results showed the greatest consistency between countries, with RRs ranging from 3.9% (Germany) to 9.5% (Rest of Europe). Most countries showed similar or lower RRs for TSH compared with MWH although, for some countries (e.g., United Kingdom, Nordic), these were higher. There was less difference in RRs for TSH lenses

  4. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty

    Directory of Open Access Journals (Sweden)

    Andleeb Zafar

    2018-02-01

    Full Text Available Purpose: We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. Methods: The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK, and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Results: Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. Conclusion: A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye.

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... have given blind patients some functional vision, using human embryonic stem cells. Two blind patients regained enough sight to read again after getting stem cell implants in their damaged eyes. ... EyeSmart Resources for Professionals Link your website to EyeSmart Embed ...

  6. Short-term corneal changes with gas-permeable contact lens wear in keratoconus subjects: a comparison of two fitting approaches.

    Science.gov (United States)

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose-Manuel

    2015-01-01

    To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-point-touch fitting approach. The lens' back optic zone radius (BOZR) was 0.4mm and 0.1mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p<0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p<0.05). Significant reduction was found over time in CCA (p=0.001) and anterior corneal asphericity in both groups (p<0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p<0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p<0.05). Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apical-touch was associated with greater corneal flattening in comparison to three-point-touch lens wear. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Get follow up exams with your eye care provider. If you notice redness, swelling, excessive discharge, pain or discomfort from wearing contact lenses, remove the lenses and seek immediate medical attention from an ophthalmologist. Related resources: Learn how to properly care for contact lenses . ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to enhance their costumes. From ... MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far ... Use Facts About Colored Contacts and Halloween Safety Colored ...

  9. Contact lens use and its compliance for care among healthcare workers in Pakistan

    Directory of Open Access Journals (Sweden)

    Muhammed Hamza Khan

    2013-01-01

    Full Text Available Background: Poor care and hygiene of contact lens (CL results in eye problems and infections. Healthcare workers have an important role in advocating correct lens care. Objectives: To determine the practices of CL care and the adverse consequences of poor CL care among healthcare workers. Setting and Design: A cross-sectional study in one public and three private sector hospitals in Karachi, Pakistan, in 2009-2010. Materials and Methods: We questioned 500 healthcare workers of all ages and both sexes, who wore CL, about compliance with advice on care and any complications due to improper hygiene practices. Ethical approval was obtained. Chi-square tests were used to determine significance and p-value less than 0.05 was considered statistically significant. Results: Of the total CL users, 385 (77% were females. Most (75% respondents wore CL to correct myopia, whereas 54% wore CL only occasionally. Surprisingly, only 24% knew the CL cleaning protocol. Lens solution was changed daily by 33% of users and after more than 2 weeks by 42%. Although 412 (82% participants practised reasonable hand hygiene before inserting CL, 88 (18% did not. Infection and eye dryness were statistically significantly (P < 0.01 associated with sex, hand-washing, and frequency of CL use. Conclusion: Noncompliance with the CL protocol was common among healthcare workers in our society. This behavior calls for targeted health education and awareness programs for healthcare workers.

  10. Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2013-04-01

    Full Text Available PURPOSE: To evaluate distance and near contrast sensitivity (CS under photopic and mesopic conditions before and after refractive lens exchange (RLE and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model intraocular lens (IOL. METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively were measured before and 6 months postoperatively. Monocular CS function was measured at three different luminance levels (85, 5 and 2.5 cd/m² before and after RLE. Post-implantation results at 6 months were compared with those found before surgery. RESULTS: Our results revealed that patients in both groups obtained good UCVA and BCVA after RLE at distance and near vision in relation to pre-surgery values. No statistically significant differences were found between the values of CS pre and post-RLE at distance and near, at any lighting condition and spatial frequency (p>0.002. CONCLUSIONS: Refractive lens exchange with aspheric AcrySof ReSTOR IOL in myopic and hyperopic population provided good visual function and yield good distance and near CS under photopic and mesopic conditions.

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... eye-care team . Consumer warning about the improper use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by the FDA? Check the FDA's database of approved contact lenses . Related Stories Prevent Infection ...

  12. Resultados topográficos en pacientes portadores de lentes de contacto Topographic results achieved patients wearing contact lens

    Directory of Open Access Journals (Sweden)

    Tania Aymeé Díaz Martínez

    2009-06-01

    results achieved in patients wearing contact lens, who were candidates to refractive surgery with Excimer laser at "Carlos J. Finlay" hospital; to determine the behaviour according to age and sex; to find out the type of contact lens used and the length of wear; and to identify the relationship of the induced corneal topographic pattern in contact lens wearers with corneal warpage and ketatoconus. METHODS: A retrospective study of the corneal topography of candidates to refractive surgery in the last 2 years was performed in 80 patients (contact lens wearers. OPTIKON AMF510P and HUMPHREY topographers were the instruments to screen the patients. All of them were performed a complete ophthalmological exam (manifest refraction, biomicroscopy, keratometry, pachymetry and corneal topography. Results and their stability were compared. Also age, sex, type of lenses and length of wear were analyzed. RESULTS: One hundred and fifty eight eyes were treated, 83 of them presented with normal topographic pattern whereas 58 had contact lens-induced corneal warpage and 17 suffered keratoconus. The average age of patients was 27 years. Mean corneal astigmatism in patients with keratoconus was -3.25 D and in patients with corneal warpage -1.12 D. The reading of the most even meridian in patients with keratocomus was 46,75 dioptries and with corneal warpage was 43,25 D. As to keratoconus, the most curved meridian reading was 54,75 dioptres and in corneal warpage was 46 dioptres. CONCLUSIONS: The type of contact lens and the length of wear has an effect on the occurrence of induced corneal warpage and subclinical keratoconus, and both recorded a similar topographic pattern.

  13. Facoemulsificación e implante de lente intraocular en cataratas causadas por uveitis Phacoemulsification and intraocular lens implantation in patients with cataract caused by uveitis

    Directory of Open Access Journals (Sweden)

    Dayamí Pérez Gómez

    2008-06-01

    Full Text Available OBJETIVO: Evaluar los resultados de la facoemulsificación y el implante de lente intraocular en cataratas causadas por uveítis. MÉTODOS: Se estudiaron 37 ojos con 6 meses de inactividad inflamatoria, agudeza visual menor de 0,6 y edad media de 47 años. Se excluyeron otras enfermedades que disminuyeran la visión. En el preoperatorio se prescribió antiinflamatorios. Se realizó la facoemulsificación con implante de lente intarocular (PMMA, óptica 6 mm; durante el seguimiento desde 24 h/6 meses se indicó antiinflamatorios esteroideos, no esteroideos e inmunosupresores hasta 6 semanas. RESULTADOS: Se observaron numerosas alteraciones del segmento anterior secundarias a las uveítis padecidas (posquirúrgicas, inespecíficas, ciclítis heterocrómica de Fuchs, postraumáticas, síndrome de Reiter, por toxoplasmosis y otras coroiditis infecciosas y por artritis reumatoide juvenil. No hubo recurrencia posquirúrgica de la uveítis en 9 ojos (24,3 %. Las complicaciones estuvieron relacionadas con la uveítis, la cirugía, la actividad inflamatoria, y la reacción del epitelio capsular. La opacidad capsular posterior apareció en 11 pacientes (29,7 % asociada a edad joven. La evolución individual se consideró satisfactoria en 30 (81,1 % pacientes con mejoría de la visión hasta 0,8-1,0 en 28 (75,6 % y 0,5-0,6 en 2 (5,4 %. CONCLUSIONES: La facoemulsificación con implante de lente intarocular es de gran utilidad en las cataratas posuveítis al condicionar poca agresión quirúrgica, ser controlable la inflamación y proporcionar buenos resultados visuales además del reordenamiento anatomofisiológico del segmento anterior.OBJECTIVE: To assess the results of phacoemulsification and intraocular lens implantation in cataracts caused by uveitis. METHODS: Thirty seven eyes with no inflammation for 6 months, visual acuity below 0.6 and average age of 47 years were studied. Other diseases affecting the vision were excluded. The preoperative

  14. Clinical observation on bandage type corneal contact lens applied after pterygium excision combined with fresh amniotic membrane transplantation

    Directory of Open Access Journals (Sweden)

    Bin Zhang

    2018-04-01

    Full Text Available AIM: To evaluate the clinical effect of fresh amniotic membrane transplantation in combination with bandage type corneal contact lens in the treatment of pterygium. METHODS: This study was a prospective analysis of 600 pterygium excision patients(600 cases, 600 eyesin the He Eye Hospital from January 2016 to June 2016. The patients were randomly and evenly divided into two groups: observation group and control group, 300 cases in each group(300 eyes. Observation group wore the bandage type corneal contact lens after surgery and took it down at fifth day. The control group did not. The degree of pain after surgery were evaluated at 2h, 1, 3 and 5d after surgery. The clinical outcomes in these two groups were compared in a 12mo postoperative follow-up observation. RESULTS: There were no significant differences between the observation and control group in the percentage of age and gender and size of the pterygium(P>0.05. After surgery, the degree of pain of treatment group significantly decreased compared to control group, the difference was statistically significant(PP>0.05. CONCLUSION: Bandage contact lenses could significantly release pain response after pterygium excision. But it can not reduce the recurrence rate.

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... enough sight to read again after getting stem cell implants in their damaged eyes. Ocular Melanoma Cases Getting Nationwide Attention MAY 03, ... re edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human-made versions. U.S. News Highlights ...

  16. Novel hybrid drilling protocol: evaluation for the implant healing--thermal changes, crestal bone loss, and bone-to-implant contact.

    Science.gov (United States)

    Calvo-Guirado, José Luis; Delgado-Peña, Jorge; Maté-Sánchez, Jose E; Mareque Bueno, Javier; Delgado-Ruiz, Rafael Arcesio; Romanos, Georgios E

    2015-07-01

    To evaluate a new hybrid drilling protocol, by the analysis of thermal changes in vitro, and their effects in the crestal bone loss and bone-to-implant contact in vivo. Temperature changes during simulated osteotomies with a hybrid drilling technique (biologic plus simplified) (test) versus an incremental drilling technique (control) were investigated. One hundred and twenty random osteotomies were performed (60 by group) in pig ribs up to 3.75-mm-diameter drill to a depth of 10 mm. Thermal changes and time were recorded by paired thermocouples. In a parallel experiment, bilateral mandibular premolars P2, P3, P4, and first molar M1 were extracted from six dogs. After 2-month healing, implant sites were randomly prepared using either of the drilling techniques. Forty eight implants of 3.75 mm diameter and 10 mm length were inserted. The dogs were euthanized at 30 and 90 days, and crestal bone loss (CBL) and bone-to-implant contact (BIC) were evaluated. The control group showed maximum temperatures of 35.3 °C ± 1.8 °C, ΔT of 10.4 °C, and a mean time of 100 s/procedure; meanwhile, the test group showed maximum temperatures of 36.7 °C ± 1.2 °C, ΔT of 8.1 °C, and a mean time of 240 s/procedure. After 30 days, CBL values for both groups (test: 1.168 ± 0.194 mm; control: 1.181 ± 0.113 mm) and BIC values (test: 43 ± 2.8%; control: 45 ± 1.3%) were similar, without significant differences (P > 0.05). After 90 days, CBL (test: 1.173 ± 0.187 mm; control: 1.205 ± 0.122 mm) and BIC (test: 64 ± 3.3%; control: 64 ± 2.4%) values were similar, without significant differences (P > 0.05). The BIC values were increased at 90 days in both groups compared with the 30-day period (P drilling procedure in vitro. Crestal bone loss and bone-to-implant contact in the hybrid drilling protocol are comparable with the conventional drilling protocol and do not affect the osseointegration process in vivo. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Temporary Piggyback Intraocular Lens Implantation Versus Single Intraocular Lens Implantation in Congenital Cataracts: Long-Term Clinical Outcomes.

    Science.gov (United States)

    Hwang, Sungsoon; Lim, Dong Hui; Lee, Soomin; Choi, Daye Diana; Chung, Eui-Sang; Chung, Tae-Young

    2018-04-01

    To report the long-term results of temporary piggyback IOL implantation in congenital cataract and to compare the clinical outcomes of temporary piggyback IOL with those of single IOL implantation. This is a retrospective, comparative, interventional study. The medical records of all consecutive patients who underwent cataract extraction and single or temporary piggyback IOL implantation within the first 3 years of life from 1999 to 2013 at Samsung Medical Center were reviewed. Twenty-eight eyes from 18 patients underwent single IOL implantation (monopseudophakia group), and 32 eyes of 20 patients underwent temporary piggyback IOL implantation in congenital cataract surgery (polypseudophakia group). The mean age at initial cataract surgery was 15.8 months in the monopseudophakia group and 11.1 months in the polypseudophakia group (P = 0.144). The average follow-up duration was 133 months in the monopseudophakia group and 120 months in the polypseudophakia group (P = 0.391). The best-corrected visual acuity at the last visit was 0.36 logMAR in the monopseudophakia group and 0.55 logMAR in the polypseudophakia group (P = 0.044). Four (14%) and 14 (44%) reoperations for complications within the anterior segment were performed in the monopseudophakia group and polypseudophakia group, respectively (P = 0.042). Four cases (14.3%) in the monopseudophakia group and 13 cases (40.6%) in the polypseudophakia group had a glaucoma-related adverse event (P = 0.086). Compared with primary single IOL implantation in congenital cataract, temporary piggyback IOL implantation produced worse visual acuity, higher reoperation rate, and higher risk of secondary glaucoma. Temporary piggyback IOL implantation does not have benefit in congenital cataract.

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... eye-care professional. Retailers that sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of the lenses found online or in beauty salons, novelty shops or in pop-up ... contact lenses from a retailer that does not ask for a prescription. ...

  19. Evaluation of a contact lens-embedded sensor for intraocular pressure measurement.

    Science.gov (United States)

    Twa, Michael D; Roberts, Cynthia J; Karol, Huikai J; Mahmoud, Ashraf M; Weber, Paul A; Small, Robert H

    2010-08-01

    To evaluate a novel contact lens-embedded pressure sensor for continuous measurement of intraocular pressure (IOP). Repeated measurements of IOP and ocular pulse amplitude (OPA) were recorded in 12 eyes of 12 subjects in sitting and supine positions using 3 configurations of the dynamic contour tonometer: slit-lamp mounted (DCT), hand-held (HH), and contact lens-embedded sensor (CL). The IOP and OPA for each condition were compared using repeated measures ANOVA and the 95% limits of agreement were calculated. The sitting IOP (mean and 95% CI) for each configuration was DCT: 16.3 mm Hg (15.6 to 17.1 mm Hg), HH: 16.6 mm Hg (15.6 to 17.6 mm Hg), and CL: 15.7 mm Hg (15 to 16.3 mm Hg). The sitting OPA for each configuration was DCT: 2.4 mm Hg (2.1 to 2.6 mm Hg), HH: 2.4 mm Hg (2.1 to 2.7 mm Hg), and CL: 2.1 mm Hg (1.8 to 2.3 mm Hg). Supine IOP and OPA measurements with the CL and HH sensors were both greater than their corresponding sitting measurements, but were significantly less with the CL sensor than the HH sensor. The mean difference and 95% Limits of Agreement were smallest for the DCT and CL sensor comparisons (0.7+/-3.9 mm Hg) and widest for the CL and HH sensors (-1.9+/-7.25 mm Hg); these wider limits were attributed to greater HH measurement variability. The CL sensor was comparable to HH and DCT sensors with sitting subjects and is a viable method for measuring IOP and OPA. Supine measurements of IOP and OPA were greater than sitting conditions and were comparatively lower with the CL sensor. HH measurements were more variable than CL measurements and this influenced the Limits of Agreement for both sitting and supine conditions.

  20. Non-Contact Measurement of Thermal Diffusivity in Ion-Implanted Nuclear Materials

    Science.gov (United States)

    Hofmann, F.; Mason, D. R.; Eliason, J. K.; Maznev, A. A.; Nelson, K. A.; Dudarev, S. L.

    2015-11-01

    Knowledge of mechanical and physical property evolution due to irradiation damage is essential for the development of future fission and fusion reactors. Ion-irradiation provides an excellent proxy for studying irradiation damage, allowing high damage doses without sample activation. Limited ion-penetration-depth means that only few-micron-thick damaged layers are produced. Substantial effort has been devoted to probing the mechanical properties of these thin implanted layers. Yet, whilst key to reactor design, their thermal transport properties remain largely unexplored due to a lack of suitable measurement techniques. Here we demonstrate non-contact thermal diffusivity measurements in ion-implanted tungsten for nuclear fusion armour. Alloying with transmutation elements and the interaction of retained gas with implantation-induced defects both lead to dramatic reductions in thermal diffusivity. These changes are well captured by our modelling approaches. Our observations have important implications for the design of future fusion power plants.

  1. Non-Contact Measurement of Thermal Diffusivity in Ion-Implanted Nuclear Materials

    International Nuclear Information System (INIS)

    Hofmann, F.; Mason, D. R.; Eliason, J. K.; Maznev, A. A.; Nelson, K. A.; Dudarev, S. L.

    2015-01-01

    Knowledge of mechanical and physical property evolution due to irradiation damage is essential for the development of future fission and fusion reactors. Ion-irradiation provides an excellent proxy for studying irradiation damage, allowing high damage doses without sample activation. Limited ion-penetration-depth means that only few-micron-thick damaged layers are produced. Substantial effort has been devoted to probing the mechanical properties of these thin implanted layers. Yet, whilst key to reactor design, their thermal transport properties remain largely unexplored due to a lack of suitable measurement techniques. Here we demonstrate non-contact thermal diffusivity measurements in ion-implanted tungsten for nuclear fusion armour. Alloying with transmutation elements and the interaction of retained gas with implantation-induced defects both lead to dramatic reductions in thermal diffusivity. These changes are well captured by our modelling approaches. Our observations have important implications for the design of future fusion power plants

  2. Implantation of a double iris-claw intraocular lens in an aphakic nanophthalmic eye

    Directory of Open Access Journals (Sweden)

    Filiz Avsin Ozdemir Sarioglu

    2017-01-01

    Full Text Available A 55-year-old female with an aphakic nanophthalmic eye underwent a secondary intraocular lens implantation (IOL with double Artisan aphakia iris claw IOLs (ICIOLs and was evaluated in this research. The patient's preoperative best-corrected visual acuity (BCVA of the right eye was 0.4 (0.4 logMAR (with + 21.00 D, postoperative 1st and 3rd month, 1st year, and 3 years BCVAs were 0.4 (0.4 logMAR. The intraocular pressure was 15 mmHg preoperatively, and 14, 12, 12, and 15 mmHg postoperatively at 1st and 3rd month, 1st year, and 3 years, respectively. The preoperative endothelial cell density (ECD was 2372 cells/mm2, and postoperative ECDs were 2352, 2391, 2246, and 2240 cells/mm2 at 1st and 3rd months, at 1st year, and 3 years respectively. In aphakic nanophthalmic eyes with inadequate capsular support, which require high IOL dioptry, the implantation of double ICIOLs (one in front of the iris and the other behind the iris seems to be safe and provides good visual rehabilitation.

  3. Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2012-06-01

    Full Text Available PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively. The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group. CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.

  4. Tear ascorbic acid levels and the total antioxidant status in contact lens wearers: A pilot study

    Directory of Open Access Journals (Sweden)

    Venkata Sai

    2009-01-01

    Full Text Available Aims: The tear ascorbate owing to its high concentration, functions as an effective antioxidant against the oxidative damage of cornea. Contact lens wearers (CLW are prone to oxidative stress due to the lens-induced hypoxic conditions. A pilot study was done to compare the tear ascorbic acid level and the total antioxidant capacity give as in normal and CLW. Materials and Methods: In this study 21 CLW (Mean age 23 ± 3 years ; M-2, F-19, who were daily wear users, with duration of wear not more than four years, along with age-matched 28 controls (Mean age 28 ± 3 ; M-15, F-13 were recruited in the study for collection of reflex tears using Schirmer′s strip. Ascorbic acid in tears was determined using high-performance liquid chromatography (HPLC, total antioxidant capacity (TAC and total protein assay by spectrophotometric analysis. Results: CLW showed no significant change in the tear ascorbic acid levels (0.4 ± 0.26 mM compared to the control subjects (0.61 ± 0.59 mM. The amount of ascorbic acid in tears did not correlate with the TAC or the total protein of the tears. The mean TAC in CLW was 0.69 ± 0.16 mM, with a total protein of 1.35 ± 0.46 mg/ml while in controls it was 0.7 ± 0.18 mM and 1.21 ± 0.47 mg/ml respectively . Conclusions: Soft contact lens wear did not show any significant change in tear ascorbic acid, TAC and total protein levels compared to controls.

  5. Method for producing an isoplanatic aspheric monofocal intraocular lens, and resul ting lens

    OpenAIRE

    Barbero, Sergio; Marcos, Susana; Dorronsoro, Carlos; Montejo, Javier; Salazar Salegui, Pedro

    2010-01-01

    [EN] The invention can be used to obtain isoplanatic aspheric mono focal intraocular lenses in a viewing range of up to 25° (preferably up to 10°). The method comprises the following steps: l. mathematical defmition of an aphakic eye model; 2. mathematical definition of an intraocular lens model; 3. mathematical defmition of the implantation of the lens; 4. mathematical defmition of the merit function; 5. definition of the contour conditions; 6. defmition of a measurement for charact...

  6. Computerized videokeratoscopy contact lens software for RGP fitting in a bilateral postkeratoplasty patient: a clinical case report.

    Science.gov (United States)

    Szczotka, L B; Reinhart, W

    1995-01-01

    Computerized videokeratoscopy systems now allow interactive rigid gas permeable (RGP) fitting evaluation using fluorescein pattern simulations through updated software programs. We used Computed Anatomy's Topographic Modeling System-1 (TMS-1) Custom Design Contact Lens Program successfully to refit a symptomatic bilateral post-penetrating keratoplasty patient. No trial lenses were used. For each eye the base curve, optic zone size, and edge lift were chosen from the optimal fluorescein pattern designed and titrated on the TMS-1 unit. Lens powers were based on the patient's previous lenses and overrefraction. Dispensed lenses provided a clinically acceptable fit, good comfort, and maximal visual acuity, and no adjustments were necessary. Corneal videokeratoscopy can be successfully employed to titrate an RGP fit, even on irregular corneas.

  7. Effects of C+ ion implantation on electrical properties of NiSiGe/SiGe contacts

    International Nuclear Information System (INIS)

    Zhang, B.; Yu, W.; Zhao, Q.T.; Buca, D.; Breuer, U.; Hartmann, J.-M.; Holländer, B.; Mantl, S.; Zhang, M.; Wang, X.

    2013-01-01

    We have investigated the morphology and electrical properties of NiSiGe/SiGe contact by C + ions pre-implanted into relaxed Si 0.8 Ge 0.2 layers. Cross-section transmission electron microscopy revealed that both the surface and interface of NiSiGe were improved by C + ions implantation. In addition, the effective hole Schottky barrier heights (Φ Bp ) of NiSiGe/SiGe were extracted. Φ Bp was observed to decrease substantially with an increase in C + ion implantation dose

  8. Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator

    Directory of Open Access Journals (Sweden)

    Cari Pérez-Vives

    2014-04-01

    Full Text Available Purpose: To compare optical and visual quality of implantable collamer lens (ICL implantation and femtosecond laser in situ keratomileusis (F-LASIK for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF and point spread function (PSF were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MTF. ICL cases showed less spread out of PSF than F-LASIK cases. ICL cases showed better visual acuity values than F-LASIK cases for all pupils, contrasts, and myopic treatments (p0.05. For -6-D myopia, however, statistically significant differences in contrast sensitivities were found for both pupils for all evaluated spatial frequencies (p<0.05. Contrast sensitivities were better after ICL implantation than after F-LASIK. Conclusions: ICL implantation and F-LASIK provide good optical and visual quality, although the former provides better outcomes of MTF, PSF, visual acuity, and contrast sensitivity, especially for cases with large refractive errors and pupil sizes. These outcomes are related to the F-LASIK producing larger high-order aberrations.

  9. Toric intraocular lens implantation versus astigmatic keratotomy to correct astigmatism during phacoemulsification.

    Science.gov (United States)

    Titiyal, Jeewan S; Khatik, Mukesh; Sharma, Namrata; Sehra, Sri Vatsa; Maharana, Parfulla K; Ghatak, Urmimala; Agarwal, Tushar; Khokhar, Sudarshan; Chawla, Bhavana

    2014-05-01

    To compare toric intraocular lens (IOL) implantation and astigmatic keratotomy (AK) in correction of astigmatism during phacoemulsification. Tertiary care hospital. Prospective randomized trial. Consecutive patients with visually significant cataract and moderate astigmatism (1.25 to 3.00 diopters [D]) were randomized into 2 groups. Temporal clear corneal 2.75 mm phacoemulsification with toric IOL implantation was performed in the toric IOL group and with 30-degree coupled AK at the 7.0 mm optic zone in the keratotomy group. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, keratometry, topography, central corneal thickness, and endothelial cell density were evaluated preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively. The study enrolled 34 eyes (34 patients), 17 in each group. There was no difference in UDVA or CDVA between the 2 groups at any follow-up visit. The mean preoperative and postoperative refractive cylinder was 2.00 D ± 0.49 (SD) and 0.33 ± 0.17 D, respectively, in the toric IOL group and 1.95 ± 0.47 D and 0.57 ± 0.41 D, respectively, in the keratotomy group (P=.10). The mean residual astigmatism at 3 months was 0.44 ± 1.89 @ 160 in the toric IOL group and 0.77 ± 1.92 @ 174 in the keratotomy group (P=.61). All eyes in the toric IOL group and 14 eyes (84%) in the keratotomy group achieved a residual refractive cylinder of 1.00 D or less (P=.17). Toric IOL implantation was comparable to AK in eyes with moderate astigmatism having phacoemulsification. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience

    Science.gov (United States)

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Purpose Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Setting Cataract services, Shroff Eye Centre, New Delhi, India. Design Case series. Method This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. Results The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76). Conclusion We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery. PMID:26586976

  11. The role of type III secretion system and lens material on adhesion of Pseudomonas aeruginosa to contact lenses.

    Science.gov (United States)

    Shen, Elizabeth P; Tsay, Ruey-Yug; Chia, Jean-San; Wu, Semon; Lee, Jing-Wen; Hu, Fung-Rong

    2012-09-21

    To determine the distribution of invasive and cytotoxic genotypes among ocular isolates of P. aeruginosa and investigate the influence of the type III secretion system (T3SS) on adhesion to conventional, cosmetic, and silicone hydrogel contact lenses (CL). Clinical isolates from 2001 to 2010 were analyzed by multiplex PCR for exoS, exoU, and exoT genes. Bacterial adhesion to etafilcon, nelfilcon (gray colored), balafilcon, and galyfilcon CL with or without artificial tear fluid (ATF) incubation were compared. Surface characteristics were determined with scanning electron microscopy (SEM). Among 87 total isolates, 64 strains were from microbial keratitis cases. CL-related microbial keratitis (CLMK) isolates were mostly of the cytotoxic genotype (expressing exoU) (P = 0.002). No significant differences were found in bacterial adhesion to all types of CL between the genotypes under T3SS-inducing conditions. A trend for least bacterial adhesion of galyfilcon compared to the other CL was noted for both genotypes. Needle complex pscC mutants adhered less to all materials than the wild type (P bacteria adhering on CL surfaces. CLMK isolates were mostly of cytotoxic genotype. Different genotypes did not significantly differ in its adhesion to various CL. T3SS and other adhesins are involved in bacteria-contact lens adhesion through complex interactions. Contact lens materials may also play an important role in the adherence of both genotypes of P. aeruginosa.

  12. Resonance frequency analysis, insertion torque, and bone to implant contact of 4 implant surfaces: comparison and correlation study in sheep.

    Science.gov (United States)

    Dagher, Maroun; Mokbel, Nadim; Jabbour, Gabriel; Naaman, Nada

    2014-12-01

    Primary stability is evaluated using resonance frequency analysis (RFA) and insertion torque (IT). Although there is a strong correlation between RFA and IT, studies failed to find a correlation between RFA and bone to implant contact (BIC) or IT and BIC. To compare RFA, IT, and BIC of SLA, SLActive, Euroteknika, and TiUnite implant surfaces and evaluate the correlation between them. Thirty-two implants were placed in 8 sheep. RFA and IT were recorded. Animals were killed at 1 and 2 months. A significant difference was found in RFA between the 4 surfaces. No significant difference was found for IT. Mean BIC was different between all 4 surfaces. A significant positive correlation was found between RFA and IT with SLA. No significant correlation was found between RFA and BIC and between IT and BIC at 1 and 2 months. Implants with 4 different surfaces have similar IT values but different RFA and BIC. Additionally irrespective of the implant surface, there is no correlation between IT and BIC and between RFA and BIC.

  13. DYNAMIC CHANGES OF THE POSTERIOR POLE OF THE EYE AFTER CATARACT PHACOEMULSIFICATION WITH INTRAOCULAR LENS IMPLANTATION

    Directory of Open Access Journals (Sweden)

    M. Р. Yugay

    2017-01-01

    Full Text Available Objective. To study the effect of uncomplicated phacoemulsification through the corneal incision with implantation of the intraocular lens (IOL for changes in the macular region of the retina. Methods: The study included 35 eyes of 35 patients who underwent uncomplicated phacoemulsification with IOL implantation. The average age of the patients was 67±2,3 years, among them were 19 women and 16 men. Exclusion criteria: retinal pathology (postthrombotic and diabetic retinopathy, wet form of age-related macular degeneration and other diseases of the retina, previous eye injuries, uveitis, intra-operative complications. Retinal thickness in the fovea, the macula, and macular volume were measured by optical coherence tomography on the first day, after 2 weeks, 1 and 3 months after surgery. Results. In the period between the first day and two weeks after surgery there were the statistically significant incensement in retinal thickness in the macula from 306,64±21,15 mkm to 321,46±27,83 mkm (p <0.05, in the fovea from 211,45±20,24 mkm to 218,69±17,84 mkm (p<0.05, macular volume from 8,08±0,35 cubic mm to 8,46±0,54 cubic mm were registered. By the end of the first month after surgery maximum retinal thickness was 327,23±27,16 mkm, thickness in the fovea 220,31±18,63 mkm, macular volume 8,61±0,55 cubic mm. After 3 months, the maximum thickness of the retina reached 325,11±26,13 mkm, in the fovea 220,31±18,63 mkm, macular volume 8,55±0,49 cubic mm. Conclusion. There was an incensement of macular volume and retinal thickness in the period between the first day and two weeks after uncomplicated cataract phacoemulsification with intraocular lens implantation. The growth of these indicators continued within the first month after surgery, three months after phacoemulsification there was a downward trend. This can be important in determining the duration of drug therapy in the postoperative period.

  14. Oxygen permeability (Dk) of thirty-seven rigid contact lens materials.

    Science.gov (United States)

    Benjamin, William J; Cappelli, Quido A

    2002-02-01

    Oxygen permeability (Dk) was determined for 37 available rigid contact lens materials in a masked fashion. The results were compared with those of an earlier study that included different lots of 14 test materials assessed in the current study. Six lenses of different thicknesses in each test and reference material were obtained. Test materials were arranged in sets of six to eight materials per set. Each set of materials, with inclusion of at least two reference materials for the purpose of simultaneous calibration, was measured to obtain preliminary amperages. Four preliminary measures were performed per thickness, resulting in 24 per material, in a schedule designed to spread the potential effects of machine drift and other factors. The mean preliminary amperages were used to derive corrected Dk values according to American National Standards Institute (ANSI) Z80.20-1998, and the values were linearly calibrated using the measured and established Dk values of the reference materials. The resistance (t/Dk) vs. thickness (t) plots for the 37 test and seven reference materials were approximated linearly. In 54 of 57 linear regressions, the coefficients of determination (R2) were >0.96, and in 48 instances were >0.98. Fourteen Dk values from the current study and an earlier study were linearly correlated (R2 = 0.9846), with a slope close to unity (+1.056) and intercept close to zero (-0.292). Ten of the current values fell within 10% of their corresponding earlier values. Only three current Dk values fell outside of the ANSI Z80.20-1998 tolerance for Dk (+/-20%). Two of these Dk values met the product tolerance when an obvious outlying point was graphically identified and omitted from the linear resistance (t/Dk) vs. thickness (t) regression. Omission of a single outlying point from a linear resistance vs. thickness regression can help provide a more valid Dk value. The ANSI Z80.20-1998 tolerance of +/-20% on Dk and the measurement reproducibility of +/-10% were

  15. Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones.

    Science.gov (United States)

    Elsherif, Mohamed; Hassan, Mohammed Umair; Yetisen, Ali K; Butt, Haider

    2018-05-17

    Low-cost, robust, and reusable continuous glucose monitoring systems that can provide quantitative measurements at point-of-care settings is an unmet medical need. Optical glucose sensors require complex and time-consuming fabrication processes, and their readouts are not practical for quantitative analyses. Here, a wearable contact lens optical sensor was created for the continuous quantification of glucose at physiological conditions, simplifying the fabrication process and facilitating smartphone readouts. A photonic microstructure having a periodicity of 1.6 μm was printed on a glucose-selective hydrogel film functionalized with phenylboronic acid. Upon binding with glucose, the microstructure volume swelled, which modulated the periodicity constant. The resulting change in the Bragg diffraction modulated the space between zero- and first-order spots. A correlation was established between the periodicity constant and glucose concentration within 0-50 mM. The sensitivity of the sensor was 12 nm mM -1 , and the saturation response time was less than 30 min. The sensor was integrated with commercial contact lenses and utilized for continuous glucose monitoring using smartphone camera readouts. The reflected power of the first-order diffraction was measured via a smartphone application and correlated to the glucose concentrations. A short response time of 3 s and a saturation time of 4 min was achieved in the continuous monitoring mode. Glucose-sensitive photonic microstructures may have applications in point-of-care continuous monitoring devices and diagnostics at home settings.

  16. The effect of boron implantation on the corrosion behaviour, microhardness and contact resistance of copper and silver surfaces

    International Nuclear Information System (INIS)

    Henriksen, O.; Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.

    1986-01-01

    In order to investigate the influence of boron implantation on the corrosion resistance of electrical contacts, a number of pure copper, pure silver and copper edge connector samples have been implanted with boron (40 keV) to fluences of 5.10 20 m -2 and 2.10 21 m -2 . Atmospheric corrosion tests of the implanted species were conducted using the following exposures: H 2 S (12.5 ppm, 4 days), SO 2 (25 ppm, 21 days), saltfog (5% NaCl, 1 day), moist air (93% RH, 56 days), and hot/dry air (70 C, 56 days). The boron implantations lead to a significant reduction in the sulphidation rate of copper and silver. The corrosive film formed during exposure in H 2 S and SO 2 atmospheres is confined to pitted regions on the implanted areas, while a thick and relatively uniform film formation is observed on the unimplanted samples. The corrosion resistance of copper and silver in saltfog atmosphere is somewhat improved by boron implantation, whilst the results from exposures to moist air or hot/dry air are inconclusive. The improved corrosion behaviour is accompanied by an increase in the contact resistance and in the microhardness of the implanted samples. (orig.)

  17. Restoring speech perception with cochlear implants by spanning defective electrode contacts.

    Science.gov (United States)

    Frijns, Johan H M; Snel-Bongers, Jorien; Vellinga, Dirk; Schrage, Erik; Vanpoucke, Filiep J; Briaire, Jeroen J

    2013-04-01

    Even with six defective contacts, spanning can largely restore speech perception with the HiRes 120 speech processing strategy to the level supported by an intact electrode array. Moreover, the sound quality is not degraded. Previous studies have demonstrated reduced speech perception scores (SPS) with defective contacts in HiRes 120. This study investigated whether replacing defective contacts by spanning, i.e. current steering on non-adjacent contacts, is able to restore speech recognition to the level supported by an intact electrode array. Ten adult cochlear implant recipients (HiRes90K, HiFocus1J) with experience with HiRes 120 participated in this study. Three different defective electrode arrays were simulated (six separate defective contacts, three pairs or two triplets). The participants received three take-home strategies and were asked to evaluate the sound quality in five predefined listening conditions. After 3 weeks, SPS were evaluated with monosyllabic words in quiet and in speech-shaped background noise. The participants rated the sound quality equal for all take-home strategies. SPS with background noise were equal for all conditions tested. However, SPS in quiet (85% phonemes correct on average with the full array) decreased significantly with increasing spanning distance, with a 3% decrease for each spanned contact.

  18. In vitro power profiles of daily disposable contact lenses.

    Science.gov (United States)

    Belda-Salmerón, Lurdes; Madrid-Costa, David; Ferrer-Blasco, Teresa; García-Lázaro, Santiago; Montés-Micó, Robert

    2013-10-01

    To evaluate and compare the distribution of refractive power within the optic zone of different soft contact lenses and to investigate the effect of lens decentration on the power profiles. The Nimo TR1504 instrument was used to measure the optical power across different aperture diameters (from 1.5mm to 5.5mm in steps of 0.5mm) of four daily disposable contact lenses: DAILIES TOTAL1, Proclear 1-Day, SofLens daily disposable and 1-DAY ACUVUE MOIST. Measurements were performed using a wet cell. Power data were evaluated when contact lenses were in its centered position and after inducing different amounts of lens decentration (from 0.2mm to 1.0mm in steps of 0.2mm). All contact lenses showed an increase - more negative - in lens power with distance from the lens center. The amount of change varied depending on the lens. It was about 10% of lens power for DAILIES TOTAL1 (-0.29diopters (D)), SofLens daily disposable (-0.36D), and Proclear 1-Day (-0.32D) whereas 1-DAY ACUVUE MOIST showed a percentage variation of 3.3% (-0.10D). After inducing a lens decentration up to 1mm, the power curves were shifted in the negative direction. However, the change obtained in lens power compared with well-centered position was always lower than a quarter of diopter both for all the lenses and aperture diameters. Our results showed a variation of the refractive power from the lens center, becoming more negative toward the periphery, with a negligible effect of the decentration for all disposable contact lenses studied. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Visual and Refractive Outcomes after Cataract Surgery with Implantation of a New Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Cinzia Mazzini

    2013-06-01

    Full Text Available Purpose: The aim of this study was to evaluate and report the visual, refractive and aberrometric outcomes of cataract surgery with implantation of the new aspheric Tecnis ZCT toric intraocular lens (IOL in eyes with low to moderate corneal astigmatism. Methods: We conducted a prospective study of 19 consecutive eyes of 17 patients (mean age: 78 years with a visually significant cataract and moderate corneal astigmatism [higher than 1 diopter (D] undergoing cataract surgery with implantation of the aspheric Tecnis ZCT toric IOL (Abbott Medical Optics. Visual, refractive and aberrometric changes were evaluated during a 6-month follow-up. Ocular aberrations as well as IOL rotation were evaluated by means of the OPD-Station II (Nidek. Results: The six-month postoperative spherical equivalent and power vector components of the refractive cylinder were within ±0.50 D in all eyes (100%. Postoperative logMAR uncorrected and corrected distance visual acuities (UDVA/CDVA were 0.1 (about 20/25 or better in almost all eyes (94.74%. The mean logMAR CDVA improved significantly from 0.41 ± 0.23 to 0.02 ± 0.05 (p Conclusion: Cataract surgery with implantation of the aspheric Tecnis ZCT IOL is a predictable and effective procedure for visual rehabilitation in eyes with cataract and low to moderate corneal astigmatism, providing an excellent postoperative ocular optical quality.

  20. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-03-01

    The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05).Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division, definition, and user

  1. Polymer-interaction driven diffusionof eyeshadow in soft contact lenses.

    Science.gov (United States)

    Tavazzi, Silvia; Rossi, Alessandra; Picarazzi, Sara; Ascagni, Miriam; Farris, Stefano; Borghesi, Alessandro

    2017-10-01

    Soft contact lenses used for the correction of ametropia are often made of hydrogel and silicone-hydrogel materials. Since they are placed directly on the surface of the eye and they are hydrated by tears, eye cosmetics can compromise the lens performance and, even worse, can be transported from an external environment to the ocular surface through the contact lens. The diffusion of the dye component of a purple eyeshadow in soft contact lenses of different materials is here evaluated. Diffusivity is found to be typically higher in silicone-hydrogels than in hydrogels. In hydrogels, diffusivity is greater in the case of lower oxygen transmissibility. Despite differences between materials, absorbed mass of dye is much larger (10-100 times) than the expected mass by simple hydration and swelling of the contact lens. The most contaminated materials are also resistant to cleaning solutions. The results indicate that, notwithstanding the complexity of contact lens networks, diffusion of dye is found to follow Fick's law and it is driven by polymer-dye interaction, which governs lens hydration and swelling. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. Microscopic and spectroscopic investigation of an explanted opacified intraocular lens

    Energy Technology Data Exchange (ETDEWEB)

    Simon, V., E-mail: viosimon@phys.ubbcluj.ro [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Radu, T.; Vulpoi, A. [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Rosca, C. [Optilens Clinic of Ophthalmology, 400604 Cluj-Napoca (Romania); Eniu, D. [Iuliu Haţieganu University of Medicine and Pharmacy, Department of Molecular Sciences, 400349 Cluj-Napoca (Romania)

    2015-01-15

    Highlights: • Changes on intraocular lens (IOL) surface after implantation. • Partial opacification of IOL central area. • Elemental composition on IOL surface prior to and after implantation. • First XPS depth profiling examination of the opacifying deposits. • Cell-mediated hydroxyapatite structuring. - Abstract: The investigated polymethylmethacrylate intraocular lens explanted an year after implantation presented a fine granularity consisting of ring-like grains of about 15 μm in diameter. In order to evidence the changes occurred on intraocular lens relative to morphology, elemental composition and atomic environments, microscopic and spectroscopic analyses were carried out using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), energy-dispersive X-ray (EDS), and X-ray photoelectron (XPS) spectroscopies. The results revealed that the grains contain hydroxyapatite mineral phase. A protein layer covers the lens both in opacified and transparent zones. The amide II band is like in basal epithelial cells. The shape and size of the grains, and the XPS depth profiling results indicate the possibility of a cell-mediated process involving lens epithelial cells which fagocitated apoptotic epithelial cells, and in which the debris derived from cell necrosis were calcified. To the best of our knowledge, this is the first investigation on explanted intraocular lenses using XPS depth profiling in order to examine the inside of the opacifying deposits.

  3. Which soft lens power is better for piggyback in keratoconus? Part II.

    Science.gov (United States)

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; González-Meijóme, Jose-Manuel; Flores-Rodriguez, Patricia; Villa-Collar, Cesar

    2015-02-01

    To evaluate how soft lens power affects rigid gas-permeable (RGP) lens power and visual acuity (VA) in piggyback fittings for keratoconus. Sixteen keratoconus subjects (30 eyes) were included in the study. Piggyback contact lens fittings combining Senofilcon-A soft lenses of -6.00, -3.00, +3.00 and +6.00 D with Rose K2 RGP contact lenses were performed. Corneal topography was taken on the naked eye and over each soft contact lens before fitting RGP lenses. Mean central keratometry, over-refraction, RGP back optic zone radius (BOZR) and estimated final power as well as VA were recorded and analyzed. In comparison to the naked eye, the mean central keratometry flattened with both negative lens powers (psoft lens power (p=1.0); and steepened with the +6.00 soft lens power (p=0.02). Rigid gas-permeable over-refraction did not change significantly between different soft lens powers (all p>0.05). RGP's BOZR decreased significantly with both positive in comparison with both negative soft lens powers (all ppowers separately (both p>0.05). Estimated RGP's final power increased significantly with positive in comparison with negative lens powers (all ppowers separately (both p>0.05). Visual acuity did not change significantly between the different soft lens powers assessed (all p>0.05). The use of negative-powered soft lenses in piggyback fitting reduces RGP lens power without impacting VA in keratoconus subjects. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  4. Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: a systematic review.

    Science.gov (United States)

    Meursinge Reynders, Reint; Ladu, Luisa; Ronchi, Laura; Di Girolamo, Nicola; de Lange, Jan; Roberts, Nia; Plüddemann, Annette

    2016-03-31

    Most orthodontic mini-implants (OMIs) are inserted between dental roots. The prevalence of contacting these structures is high. Such contacts can cause permanent root damage and implant instability. Increased torque levels during implant insertion (the index test) could be a more accurate and immediate measure for diagnosing implant-root contact (the target condition) than radiographs (the reference standard) and could ultimately lead to a reduction or elimination of X-ray exposure. To address this issue, we asked three questions: (1) whether OMIs with root contact had higher insertion torque values than those without, (2) what is the accuracy of the index test compared with the reference standard to diagnose the target condition and what are the adverse effects of the index test, and (3) whether intermediate torque values have clinical diagnostic utility. Methods were conducted according to our published protocol, which was based on the PRISMA-P 2015 statement. We applied broad spectrum eligibility criteria that included randomized and non-randomized studies on clinical, animal, and cadaver models. Not including such models would be unethical because it could slow down knowledge creation on the adverse effects of implant insertion. We conducted searches in more than 40 electronic databases including MEDLINE and 10 journals were hand-searched. Grey literature and reference lists were also searched. All research procedures were conducted independently by three reviewers. Authors of selected studies were contacted to obtain additional information. Outcomes on the three different research models were analysed separately. Systematic error was assessed with the Cochrane 'Risk of bias tool' for non-randomized studies. One clinical, two animal, and two cadaver studies fulfilled the eligibility criteria of the first research question. All studies and subgroups demonstrated higher insertion torque values for OMIs with the target condition than those without. Mean

  5. Factors influencing bacterial adhesion to contact lenses.

    Science.gov (United States)

    Dutta, Debarun; Cole, Nerida; Willcox, Mark

    2012-01-01

    The process of any contact lens related keratitis generally starts with the adhesion of opportunistic pathogens to contact lens surface. This article focuses on identifying the factors which have been reported to affect bacterial adhesion to contact lenses. Adhesion to lenses differs between various genera/species/strains of bacteria. Pseudomonas aeruginosa, which is the predominant causative organism, adheres in the highest numbers to both hydrogel and silicone hydrogel lenses in vitro. The adhesion of this strain reaches maximum numbers within 1h in most in vitro studies and a biofilm has generally formed within 24 h of cells adhering to the lens surface. Physical and chemical properties of contact lens material affect bacterial adhesion. The water content of hydroxyethylmethacrylate (HEMA)-based lenses and their iconicity affect the ability of bacteria to adhere. The higher hydrophobicity of silicone hydrogel lenses compared to HEMA-based lenses has been implicated in the higher numbers of bacteria that can adhere to their surfaces. Lens wear has different effects on bacterial adhesion, partly due to differences between wearers, responses of bacterial strains and the ability of certain tear film proteins when bound to a lens surface to kill certain types of bacteria.

  6. TESS Lens-Bezel Assembly Modal Testing

    Science.gov (United States)

    Dilworth, Brandon J.; Karlicek, Alexandra

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

  7. Experimental study on bone tissue reaction around HA implants radiated after implantation

    International Nuclear Information System (INIS)

    Kudo, Masato; Matsui, Yoshiro; Tamura, Sayaka; Chen, Xuan; Uchida, Haruo; Mori, Kimie; Ohno, Kohsuke; Michi, Ken-ichi

    1998-01-01

    This study was conducted to investigate histologically and histomorphometrically the tissue reaction around hydroxylapatite (HA) implants that underwent irradiation in 3 different periods in the course of bone healing after implantation. The cylindrical high-density HA implants were implanted in 48 Japanese white rabbit mandibles. A single 15 Gy dose was applied to the mandible 5, 14, or 28 days after implantation. The rabbits were sacrificed 7, 14, 28, and 90 days after irradiation. Nonirradiated rabbits were used as controls. CMR, labeling with tetracycline and calcein, and non-decalcified specimens stained with toluidine blue were used for histological analyses and histomorphometric measurements. The results were as follows: In the rabbits irradiated 5 days after implantation, the HA-bone contact was observed later than that in the controls and the bone-implant contact surface ratio was lower than that in the controls at examination because necrosis of the newly-formed bone occurred just after irradiation. HA-bone contact of the rabbits irradiated 14 and 28 days after implantation was similar to that of the controls. And, bone remodeling was suppressed in rabbits of each group sacrificed at 90 days after irradiation. The results suggested that a short interval between implantation and irradiation causes direct contact between HA implant and bone and a long lapse of time before irradiation hardly affects the bone-implant contact, but delays bone remodeling. Therefore, it is necessary to prevent overloading the HA implants irradiated after implantation and pay utmost attention to conditions around the bone-implant contact. (author)

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus ... Eye Health A-Z Symptoms Glasses & Contacts Tips & ...

  9. Contact lens assisted imaging with integrated flexible handheld probe for glaucoma diagnosis

    Science.gov (United States)

    Hong, Xun Jie Jeesmond; V. K., Shinoj; Murukeshan, V. M.; Baskaran, M.; Aung, Tin

    2017-06-01

    Angle closure glaucoma accounts for majority of the bilateral blindness in Asian countries such as Singapore, China, and India. Abnormalities in the optic nerve and aqueous outflow system are the most indicative clinical hallmarks for glaucoma of this clinical subtype. Traditional photographic imaging techniques to assess the drainage angle are contact based, and may expose patients to risk of corneal abrasion and infections. In addition, these procedures require the use of viscous ophthalmic gels as coupling medium to overcome the phenomenon of total internal reflection at the tear-air interface. In this paper, we propose an integrated flexible handheld probe consisting of a micro color CCD video camera and white light LEDs. The handheld probe is able to capture images of the fundus and opposite iridocorneal angle when placed at the central cornea or limbus respectively. Here, we propose the use of hydrogel contact lens as an index matching medium and better protective barrier, as an alternative to conventional ophthalmic gels. The proposed imaging system and methodology has been successfully tested on porcine eye samples, ex vivo. With its high repeatability, reproducibility, and a good safety profile, it is believed that the proposed imaging system and methodology will complement existing imaging modalities in the diagnosis and management of glaucoma.

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial ...

  11. AlGaN/GaN high electron mobility transistors with implanted ohmic contacts

    International Nuclear Information System (INIS)

    Wang, H.T.; Tan, L.S.; Chor, E.F.

    2007-01-01

    Selective area silicon implantation for source/drain regions was integrated into the fabrication of molecular beam epitaxy-grown AlGaN/GaN HEMTs. Dopant activation was achieved by rapid thermal annealing at 1100 deg. C in flowing N 2 ambient for 120 s with an AlN encapsulation. Linear transmission line measurements showed that the resistance of the overlay Ti/Al/Ni/Au ohmic contacts was reduced by 61% compared to the control sample. After the Schottky Ni/Au gate formation, the typical DC characteristics displayed a higher current drive, smaller knee voltage and better gate control properties for HEMTs with implanted source and drain regions

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus ... Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without ...

  13. Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars.

    Science.gov (United States)

    Terauchi, Rie; Arai, Korenori; Tanaka, Masahiro; Kawazoe, Takayoshi; Baba, Shunsuke

    2015-01-01

    Implant treatment is believed to cause minimal invasion of remaining teeth. However, few studies have examined teeth adjacent to an implant region. Therefore, this study investigated the effect of occlusal contact size of implants on the periodontal mechanosensitive threshold of adjacent premolars. A cross-sectional study design was adopted. The Department of Oral Implantology, Osaka Dental University, was the setting where patients underwent implant treatment in the mandibular free-end edentulous area. The study population comprised of 87 patients (109 teeth) who underwent follow-up observation for at least 3 years following implant superstructure placement. As variables, age, sex, duration following superstructure placement, presence or absence of dental pulp, occlusal contact area, and periodontal mechanosensitive threshold were considered. The occlusal contact area was measured using Blue Silicone(®)and Bite Eye BE-I(®). Periodontal mechanosensitive threshold were measured using von Frey hair. As quantitative variables for periodontal mechanosensitive threshold, we divided subjects into two groups: normal (≤5 g) and high (≥5.1 g). For statistical analysis, we compared the two groups for the sensation thresholds using the Chi square test for categorical data and the Mann-Whitney U test for continuous volume data. For variables in which a significant difference was noted, we calculated the odds ratio (95 % confidence interval) and the effective dose. There were 93 teeth in the normal group and 16 teeth in the high group based on periodontal mechanosensitive threshold. Comparison of the two groups indicated no significant differences associated with age, sex, duration following superstructure placement, or presence or absence of dental pulp. A significant difference was noted with regard to occlusal contact area, with several high group subjects belonging to the small contact group (odds ratio: 4.75 [1.42-15.87]; effective dose: 0.29). The results of

  14. Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.

    Science.gov (United States)

    Akondi, Vyas; Pérez-Merino, Pablo; Martinez-Enriquez, Eduardo; Dorronsoro, Carlos; Alejandre, Nicolás; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2017-04-01

    Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye. The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL. Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction. Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality. [J Refract Surg. 2017;33(4):257-265.]. Copyright 2017, SLACK Incorporated.

  15. Iris-fixated phakic intraocular lens implantation to correct myopia and a predictive model of endothelial cell loss.

    Science.gov (United States)

    Bouheraoua, Nacim; Bonnet, Clemence; Labbé, Antoine; Sandali, Otman; Lecuen, Nicolas; Ameline, Barbara; Borderie, Vincent; Laroche, Laurent

    2015-11-01

    To report long-term results of Artisan phakic intraocular lens (pIOL) to correct myopia and to propose a model predicting endothelial cell loss after pIOL implantation. Quinze-Vingts National Ophthalmology Hospital, Paris, France. Retrospective, interventional case series. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and central endothelial cell count (ECC) were determined before and at yearly intervals up to 5 years after pIOL implantation. Linear model analysis was performed to present a model that describes endothelial cell loss as a linear decrease and an additional decrease depending on postoperative loss. A total of 49 patients (68 eyes) implanted with pIOLs from January 2000 to January 2009 were evaluated. The mean preoperative and final spherical equivalent (SE) were -13 ± 4.10 and -0.75 ± 0.74 diopters (D), respectively. The mean preoperative and final central ECC were 2629 ± 366 and 2250 ± 454 cells/mm(2), respectively. There were no intraoperative complications for any of the eyes. One eye required surgery for repositioning the pIOL, and 1 eye required pIOL exchange for postoperative refractive error. The model predicted that for patients with preoperative ECC of 3000, 2500, and 2000 cells/mm(2), a critical ECC of 1500 cells/mm(2) will be reached at 39, 28, and 15 years after implantation, respectively. Implantation of the pIOL was an effective and stable procedure after 5 years of follow-up. The presented model predicted EC loss after pIOL implantation, which can assist ophthalmologists in patient selection and follow-up. The authors report no conflict of interest. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Contact lens-associated microbial keratitis Ceratites microbianas relacionadas a lente de contato

    Directory of Open Access Journals (Sweden)

    Aline Silveira Moriyama

    2008-12-01

    Full Text Available PURPOSE: Contact lens-associated microbial keratitis is a severe condition with sight-threatening potential and increasing incidence. Information regarding the etiological agents is essential in guiding management and may vary geographically. The aim of this study was to analyze the microbiological results of corneal scrapings collected from patients presenting with contact lens-associated microbial keratitis. METHODS: Retrospective analysis of the records of all patients who were clinically diagnosed with contact lens-associated microbial keratitis and had corneal scrapings sent to the Laboratory of Ocular Microbiology, UNIFESP/EPM during a 5-year period from January 2002 to December 2007. RESULTS: The etiological agent was identified in 239 patients. Bacterial isolates accounted for 166 (69.46% cases, Acanthamoeba for 95 (39.75% cases and fungi for 4 (1.67% cases. Among the bacterial infections, coagulase-negative Staphylococcus was demonstrated in 74 cases, while Pseudomonas spp was found in 32 patients. All coagulase negative Staphylococcus and Pseudomonas were susceptible to ciprofloxacin and ofloxacin. Resistance to gentamicin was documented in a single case of Pseudomonas. Fourth-generation flouoroquinolone resistance was not observed among Pseudomonas cases. CONCLUSION: Coagulase-negative Staphylococcus was the most frequent isolate, and such data must be considered when determining empiric treatment. Second-generation fluoroquinolones ciprofloxacin and ofloxacin and fourth-generation fluoroquinolones moxifloxacin and gatifloxacin showed a good antibacterial profile and therefore could be good options for initial management.OBJETIVO: A ceratite microbiana associada ao uso de lente de contato é uma condição clínica grave, com risco de perda visual e cuja incidência vem aumentando progressivamente. Os principais agentes etiológicos podem variar geograficamente e informações referentes aos agentes causais são essenciais para

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In ...

  20. Soft contact lens biomaterials from bioinspired phospholipid polymers.

    Science.gov (United States)

    Goda, Tatsuro; Ishihara, Kazuhiko

    2006-03-01

    Soft contact lens (SCL) biomaterials originated from the discovery of a poly(2-hydroxyethyl methacrylate) (poly[HEMA])-based hydrogel in 1960. Incorporation of hydrophilic polymers into poly(HEMA) hydrogels was performed in the 1970-1980s, which brought an increase in the equilibrium water content, leading to an enhancement of the oxygen permeability. Nowadays, the poly(HEMA)-based hydrogels have been applied in disposable SCL. At the same time, high oxygen-permeable silicone hydrogels were produced, which made it possible to continually wear SCL. Recently, numerous trials for improving the water wettability of silicone hydrogels have been performed. However, little attention has been paid to improving their anti-biofouling properties and biocompatibility. Since biomimetic phospholipid polymers possess excellent anti-biofouling properties and biocompatibility they have the potential to play a valuable role in the surface modification of the silicone hydrogel. The representative phospholipid polymers containing a 2-methacryloyloxyethyl phosphorylcholine (MPC) unit suppressed nonspecific protein adsorption, increased cell compatibility and contributed to blood compatible biomaterials. The MPC polymer coating on the silicone hydrogel improved its water wettability and biocompatibility, while maintaining high oxygen permeability compared with the original silicone hydrogel. Furthermore, the newly prepared phospholipid-type intermolecular crosslinker made it possible to synthesize a 100% phospholipid polymer hydrogel that can enhance the anti-biofouling properties and biocompatibility. In this review, the authors discuss how polymer hydrogels should be designed in order to obtain a biocompatible SCL and future perspectives.

  1. The ocular response to extended wear of a high Dk silicone hydrogel contact lens.

    Science.gov (United States)

    Fonn, Desmond; MacDonald, Karen E; Richter, Doris; Pritchard, Nicola

    2002-05-01

    A four-month extended wear clinical trial was conducted to compare the ocular effects of a high Dk Balafilcon A silicone hydrogel lens and a low Dk HEMA 38.6 per cent H20 soft lens. Twenty-four subjects who were adapted to daily wear of soft lenses wore a high Dk lens in one eye and a low Dk HEMA lens in the other eye for four months on an extended wear basis after one week of daily wear. Thirteen progress evaluations were conducted using standard clinical procedures. Eighteen subjects (75 per cent) completed the study. The high Dk lens induced significantly less bulbar and limbal injection and corneal vascularisation than the low Dk HEMA lens (p Dk lens. A significant increase in myopia was found in the eyes wearing the low Dk HEMA lens (mean = 0.50 D, p Dk lens. Three subjects developed small infiltrates in the high Dk lens wearing eyes and significantly more post-lens debris was observed under the high Dk lens. Six subjects developed papillary conjunctivitis in the eye wearing silicone hydrogel lenses but only two of those were discontinued from the study. No hypoxia-related effects were observed with extended wear of the high Dk Balafilcon A silicone hydrogel lens.

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by ... 23, 2018 Solar Eclipse Inflicts Damage in the Shape of ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  4. Activity of a melimine derived peptide Mel4 against Stenotrophomonas, Delftia, Elizabethkingia, Burkholderia and biocompatibility as a contact lens coating

    DEFF Research Database (Denmark)

    Dutta, Debarun; Zhao, Timothy; Cheah, Kai Bing

    2017-01-01

    Purpose To determine the antimicrobial activity of the melimine derived peptide Mel4 against Delftia, Stenotrophomonas, Elizabethkingia, Burkholderia and to investigate biocompatibility of Mel4 as an antimicrobial coating on contact lenses in animals and humans. Methods In vitro antimicrobial...... activity of Mel4 was determined against the four Gram negative bacteria by investigating growth curves for 24 h followed by viable counts to determine the minimum inhibitory concentration (MIC). Contact lenses were coated by covalently binding Mel4, characterized by amino acid analysis, and were...... was active against all the bacteria tested (MIC50 ranged from 31–1000 μg ml−1) and produced an antimicrobial surface on contact lenses. Mel4-coating resulted hydrophilic surface without any significant change in contact lens parameters, and showed no signs of cytotoxicity or ocular irritation during rabbit...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... a souvenir shop, but 10 hours after she first put in a pair of colored contact lenses, ... APR 24, 2018 By Kate Rauch In a first, scientists in China have created artificial photoreceptors to ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but 10 hours after ... are being sold illegally," Dr. Steinemann said. Never buy colored contact lenses from a retailer that does ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ... About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ... a laser pointer several times, according to a report published this month in the New England Journal ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not been properly fitted by an eye care professional, the lenses stuck to my eye like a ... prescription and proper fitting by an eye-care professional. Retailers that sell contacts without a prescription are ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... colored contact lenses to enhance their costumes. From blood-drenched vampire eyes to glow-in-the-dark ... properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... 13, 2017 Histoplasmosis Diagnosis Sep 01, 2017 How common is retinal detachment for people with high myopia? ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lentes de contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir ... Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored contact lenses without ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... to the journals may be interrupted during this time. We are working to resolve the issue quickly ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... the United States. All contact lenses are medical devices that require a prescription and proper fitting by ... Care Apr 23, 2018 How long does it take the eye to go back to its original ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... seek immediate medical attention from an ophthalmologist. Related resources: Learn how to properly care for contact lenses . ... have given blind patients some functional vision, using human embryonic stem cells. Two blind patients regained enough ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Halloween or any time of year, follow these guidelines: Get an eye exam from a licensed eye ... available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... that decorative lenses do not require the same level of care or consideration as a standard contact ... By Kate Rauch In a small but intriguing study, scientists in England have given blind patients some ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Peligros asociados con los lentes de contacto de color Sep. 26, 2013 It started as an impulsive ... Halloween is a popular time for people to use colored contact lenses to enhance their costumes. From ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ... 2018 By Dan T. Gudgel Do you know what the difference is between ophthalmologists and optometrists? A ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are ... this month in the New England Journal of Medicine. Unfortunately, this kind of injury is all too ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... videos on your website Promotional materials for eye health observances EyeSmart resources are also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by the ... Service For Advertisers For Media Ophthalmology Job Center © American ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology ...

  7. Clinical observation of four-fixable intraocular lens suspensory

    Directory of Open Access Journals (Sweden)

    Yu-Ming Teng

    2015-06-01

    Full Text Available AIM: To discuss the four-fixable intraocular lens(IOLsuspensory in the absence of capsular intraocular lens implantation, suspensory ligament rupture caused by congenital dislocation of the lens, traumatic cataract and posterior capsular rupture without capsular support, which need to line hanging IOL for intraoperative clinical observation.METHODS: The 31 cases(32 eyeswho were accepted the four-fixable IOL suspensory from May 2012 to May 2014 in our hospital were retrospectively analyzed. The postoperative visual acuity, corneal astigmatism, intraoperative and postoperative complications were comprehensively analyzed.RESULTS: Patients were followed up 6mo~1a, corrected visual acuity >0.5(12 eyes, 38%, 0.1~0.5(18 eyes, 56%, and CONCLUSION: It is designed to support non-capsular IOL implantation and design, and the concept of changing the past presence of suspended dislocated IOL implantation surgery, positional deviation and, sutures and other complications split the incidence is greatly reduced. It is consistent with the physiological characteristics of the human eye, and it is the IOL surgical sling best stability, intraoperative and postoperative complications, the best visual acuity and corneal astigmatism minimal surgical approachat least, and the four-point suspension suture fixation of IOL is designed to obtain a practical transformation of Chinese patent.

  8. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Vrijman, V.; El-Saady, R.; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2014-01-01

    PURPOSE: To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). METHODS: This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ... away without suffering an eye injury. However, the natural protective mechanisms of the eye – such as the ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers ... Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados con los lentes de contacto de ...

  12. Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis.

    Science.gov (United States)

    Kang, He-Kyong; Chu, Tien-Min; Dechow, Paul; Stewart, Kelton; Kyung, Hee-Moon; Liu, Sean Shih-Yao

    2016-04-01

    This study investigated the biomechanical properties and bone-implant intersurface response of machined and laser surface-treated stainless steel (SS) mini-screw implants (MSIs). Forty-eight 1.3mm in diameter and 6mm long SS MSIs were divided into two groups. The control (machined surface) group received no surface treatment; the laser-treated group received Nd-YAG laser surface treatment. Half in each group was used for examining surface roughness (Sa and Sq), surface texture, and facture resistance. The remaining MSIs were placed in the maxilla of six skeletally mature male beagle dogs in a randomized split-mouth design. A pair with the same surface treatment was placed on the same side and immediately loaded with 200 g nickel-titanium coil springs for 8 weeks. After killing, the bone-implant contact (BIC) for each MSI was calculated using micro computed tomography. Analysis of variance model and two-sample t test were used for statistical analysis with a significance level of P titanium alloy MSIs. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  13. Disinfection efficacy of contact lens care solutions against ocular pathogens.

    Science.gov (United States)

    Miller, M J; Callahan, D E; McGrath, D; Manchester, R; Norton, S E

    2001-01-01

    Three commercially available products labeled as multi-purpose contact lens solutions, one multi-purpose disinfecting solution, and a hydrogen peroxide system were evaluated for antimicrobial activity according to the current International Organization for Standardization (ISO) and the U.S. Food and Drug Administration (FDA) stand-alone procedure for disinfecting products. One multi-purpose solution was selected to assess its antimicrobial activity against two human corneal isolates of Pseudomonas aeruginosa. Products were challenged with bacteria and fungi, and following a specified period, aliquots of inoculated test solution were neutralized and plated on validated recovery media. After incubation the number of viable microorganisms was enumerated and mean log reductions determined. ReNu MultiPlus (Bausch & Lomb, Rochester, NY), AOSEPT (CIBA Vision Corporation, Duluth, GA), and Opti-Free Express with Aldox (Alcon Laboratories, Ft. Worth, TX) were the only lens care products that met the stand-alone criteria for all required microorganisms within their minimum recommended disinfection time. Of these, ReNu MultiPlus provided the greatest overall antimicrobial activity. ReNu MultiPlus demonstrated a significantly higher mean log reduction of Staphylococcus aureus and Serratia marcescens than Opti-Free Express. ReNu MultiPlus also gave a higher mean log reduction of S. aureus and S. marcescens than AOSEPT, and a higher mean log reduction of Candida albicans and Fusarium solani than AOSEPT, Complete Comfort Plus (Allergan, Irivine, CA), and Solo-Care (CIBA Vision Corp.) (at 4 hours). Both Complete Comfort Plus and Solo-Care (at 4 hours) met the primary acceptance criteria for bacteria; however, neither product possessed enough antimicrobial activity to meet the minimum criteria for yeast or mold. ReNu Multiplus was effective against corneal isolates of P. aeruginosa. ReNu MultiPlus, AOSEPT, and Opti-Free Express met the requirements of the stand-alone primary

  14. Ion implantation into amorphous Si layers to form carrier-selective contacts for Si solar cells

    International Nuclear Information System (INIS)

    Feldmann, Frank; Mueller, Ralph; Reichel, Christian; Hermle, Martin

    2014-01-01

    This paper reports our findings on the boron and phosphorus doping of very thin amorphous silicon layers by low energy ion implantation. These doped layers are implemented into a so-called tunnel oxide passivated contact structure for Si solar cells. They act as carrier-selective contacts and, thereby, lead to a significant reduction of the cell's recombination current. In this paper we address the influence of ion energy and ion dose in conjunction with the obligatory high-temperature anneal needed for the realization of the passivation quality of the carrier-selective contacts. The good results on the phosphorus-doped (implied V oc = 725 mV) and boron-doped passivated contacts (iV oc = 694 mV) open a promising route to a simplified interdigitated back contact (IBC) solar cell featuring passivated contacts. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  16. Bioinspired adaptive gradient refractive index distribution lens

    Science.gov (United States)

    Yin, Kezhen; Lai, Chuan-Yar; Wang, Jia; Ji, Shanzuo; Aldridge, James; Feng, Jingxing; Olah, Andrew; Baer, Eric; Ponting, Michael

    2018-02-01

    Inspired by the soft, deformable human eye lens, a synthetic polymer gradient refractive index distribution (GRIN) lens with an adaptive geometry and focal power has been demonstrated via multilayer coextrusion and thermoforming of nanolayered elastomeric polymer films. A set of 30 polymer nanolayered films comprised of two thermoplastic polyurethanes having a refractive index difference of 0.05 were coextruded via forced-assembly technique. The set of 30 nanolayered polymer films exhibited transmission near 90% with each film varying in refractive index by 0.0017. An adaptive GRIN lens was fabricated from a laminated stack of the variable refractive index films with a 0.05 spherical GRIN. This lens was subsequently deformed by mechanical ring compression of the lens. Variation in the optical properties of the deformable GRIN lens was determined, including 20% variation in focal length and reduced spherical aberration. These properties were measured and compared to simulated results by placido-cone topography and ANSYS methods. The demonstration of a solid-state, dynamic focal length, GRIN lens with improved aberration correction was discussed relative to the potential future use in implantable devices.

  17. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens

    NARCIS (Netherlands)

    van der Linden, Jan Willem; Vrijman, Violette; Al-Saady, Rana; El-Saady, Rana; van der Meulen, Ivanka J.; Mourits, Maarten P.; Lapid-Gortzak, Ruth

    2014-01-01

    To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric multifocal IOL (LS-312

  18. Pigment dispersion and Artisan phakic intraocular lenses: crystalline lens rise as a safety criterion.

    Science.gov (United States)

    Baïkoff, Georges; Bourgeon, Grégoire; Jodai, Horacio Jitsuo; Fontaine, Aline; Lellis, Fernando Viera; Trinquet, Laure

    2005-04-01

    To validate the theory that crystalline lens rise can be used as a safety criterion to prevent pigment dispersion in eyes with an Artisan phakic intraocular lens (IOL) (Ophtec BV). Monticelli Clinic, Marseilles, France. A comparative analysis of crystalline lens rise in 9 eyes with pigment dispersion and 78 eyes without dispersion was performed. All eyes had previous implantation of an Artisan IOL. Anterior segment imaging was done using an anterior chamber optical coherence tomography (AC OCT) prototype. Crystalline lens rise was defined by the distance between the anterior pole of the crystalline lens and the horizontal plane joining the opposite iridocorneal recesses. The study confirmed that crystalline lens rise can be considered a safety criterion for implantation of Artisan-type phakic IOLs. The higher the crystalline lens rise, the greater the risk for developing pigment dispersion in the area of the pupil. This complication occurred more frequently in hyperopic eyes than in myopic eyes. Results indicate there is little or no risk for pigment dispersion if the rise is less than 600 microm; 67% of eyes with a rise of 600 microm or more developed pupillary pigment dispersion. In some cases in which the IOL was loosely fixated, there was no traction on the iris root and dispersion was prevented or delayed. Crystalline lens rise should be considered a new safety criterion for Artisan phakic IOL implantation and should also be applied to other types of phakic IOLs. The distance remaining between the crystalline lens rise and a 600 microm theoretical safety level allows one to calculate how long the IOL can safely remain in the eye.

  19. Atomic force microscopy and Langmuir-Blodgett monolayer technique to assess contact lens deposits and human meibum extracts.

    Science.gov (United States)

    Hagedorn, Sarah; Drolle, Elizabeth; Lorentz, Holly; Srinivasan, Sruthi; Leonenko, Zoya; Jones, Lyndon

    2015-01-01

    The purpose of this exploratory study was to investigate the differences in meibomian gland secretions, contact lens (CL) lipid extracts, and CL surface topography between participants with and without meibomian gland dysfunction (MGD). Meibum study: Meibum was collected from all participants and studied via Langmuir-Blodgett (LB) deposition with subsequent Atomic Force Microscopy (AFM) visualization and surface roughness analysis. CL Study: Participants with and without MGD wore both etafilcon A and balafilcon A CLs in two different phases. CL lipid deposits were extracted and analyzed using pressure-area isotherms with the LB trough and CL surface topographies and roughness values were visualized using AFM. Meibum study: Non-MGD participant meibum samples showed larger, circular aggregates with lower surface roughness, whereas meibum samples from participants with MGD showed more lipid aggregates, greater size variability and higher surface roughness. CL Study: Worn CLs from participants with MGD had a few large tear film deposits with lower surface roughness, whereas non-MGD participant-worn lenses had many small lens deposits with higher surface roughness. Balafilcon A pore depths were shallower in MGD participant worn lenses when compared to non-MGD participant lenses. Isotherms of CL lipid extracts from MGD and non-MGD participants showed a seamless rise in surface pressure as area decreased; however, extracts from the two different lens materials produced different isotherms. MGD and non-MGD participant-worn CL deposition were found to differ in type, amount, and pattern of lens deposits. Lipids from MGD participants deposited irregularly whereas lipids from non-MGD participants showed more uniformity. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  20. Measurement of the refractive index of soft contact lenses during wear.

    Science.gov (United States)

    Varikooty, Jalaiah; Keir, Nancy; Woods, Craig A; Fonn, Desmond

    2010-01-01

    To determine whether the refractive index (RI) of a soft contact lens can be evaluated using refractometry while the lens remains on the eye and to compare this with more traditional ex vivo RI measurements. A slitlamp apparatus was modified to incorporate a customized Atago hand refractometer. With a double-masked study design, nine adapted symptomatic soft contact lens wearers wore a contact lens in each eye (lotrafilcon B and etafilcon A) in a randomized order. In vivo RI was determined from the relative Brix scale measurements immediately after lens insertion and after 1 and 10 hr of lens wear. Ex vivo refractometry was performed after 10 hr of lens wear for comparison. Means +/- standard errors of the means are reported. In vivo RI values at baseline were 1.422 +/- 0.0004 (lotrafilcon B) and 1.405 +/- 0.0021 (etafilcon A); after 1 hr of lens wear, values were 1.423 +/- 0.0006 and 1.408 +/- 0.0007, respectively; and after 10 hr of lens wear, values were 1.424 +/- 0.0004 and 1.411 +/- 0.0010, respectively. Ex vivo RI values at the end of the 10 hr wearing period were 1.424 +/- 0.0003 (lotrafilcon B) and 1.412 +/- 0.0017 (etafilcon A). The change in in vivo RI across the day was statistically significant for the etafilcon A lens (repeated-measures analysis of variance, P0.05). This novel adaptation of refractometry was able to measure the RI of soft contact lenses during wear (without lens removal). End of day RI measurements using in vivo and ex vivo refractometry were comparable with each other. Future work is required to determine whether this in vivo method can improve our understanding of the relationships between soft contact lens RI, hydration, on-eye lens performance, and symptomology.

  1. Factors influencing bacterial adhesion to contact lenses

    OpenAIRE

    Dutta, Debarun; Cole, Nerida; Willcox, Mark

    2012-01-01

    The process of any contact lens related keratitis generally starts with the adhesion of opportunistic pathogens to contact lens surface. This article focuses on identifying the factors which have been reported to affect bacterial adhesion to contact lenses. Adhesion to lenses differs between various genera/species/strains of bacteria. Pseudomonas aeruginosa, which is the predominant causative organism, adheres in the highest numbers to both hydrogel and silicone hydrogel lenses in vitro. The ...

  2. Al and Cu Implantation into Silicon Substrate for Ohmic Contact in Solar Cell Fabrication

    International Nuclear Information System (INIS)

    Sri Sulamdari; Sudjatmoko; Wirjoadi; Yunanto; Bambang Siswanto

    2002-01-01

    Research on the implantation of Al and Cu ions into silicon substrate for ohmic contact in solar cell fabrication has been carried using ion accelerator machine. Al and Cu ions are from 98% Al and 99.9% Cu powder ionized in ion source system. provided in ion implantor machine. Before implantation process, (0.5 x 1) cm 2 N type and P type silicon were washed in water and then etched in Cp-4A solution. After that, P type silicon were implanted with Al ions and N type silicon were implanted with Cu ions with the ions dose from 10 13 ion/cm 2 - 10 16 ion/cm 2 and energy 20 keV - 80 keV. Implanted samples were then annealed at temperature 400 o C - 850 o C. Implanted and annealed samples were characterized their resistivities using four point probe FPP-5000. It was found that at full electrically active conditions the ρ s for N type was 1.30 x 10 8 Ω/sq, this was achieved at ion dose 10 13 ion/cm 2 and annealing temperature 500 o C. While for P type, the ρ s was 1.13 x 10 2 Ω/sq, this was achieved at ion dose 10 13 ion/cm 2 and energy 40 keV, and annealing temperature 500 o C. (author)

  3. Broadband Loop Antenna on Soft Contact Lens for Wireless Ocular Physiological Monitoring

    Directory of Open Access Journals (Sweden)

    Ssu-Han Ting

    2014-01-01

    Full Text Available This paper presents a novel loop antenna with broadband for wireless ocular physiological monitoring (WOPM. The antenna is fabricated on a thin-film poly-para-xylylene C (parylene C substrate with a small thickness of 11 μm and dimension of π×6.5×6.5 mm2. With the advantage of small size, the proposed antenna is suitable to apply to the soft contact lens and transmit the signal in microelectromechanical Systems (MEMS. Because the pig's eye and human's eye have similar parameters of conductivity and permittivity, the experimental results are obtained by applying the proposed antenna on the pig's eye and cover from 1.54 to 6 GHz for ISM band (2.4 and 5.8 GHz applications. The measured antenna radiation patterns, antenna gains, and radiation efficiency will be demonstrated in this paper, which are suitable for application of wireless ocular physiological monitoring.

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados con los lentes de contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but 10 hours ...

  5. Lubricant effects on low Dk and silicone hydrogel lens comfort.

    Science.gov (United States)

    Ozkan, Jerome; Papas, Eric

    2008-08-01

    To investigate the influence of three lubricants of varying viscosity, on postinsertion and 6 h comfort with contact lens wear. Comfort and associated symptoms of dryness were assessed in 15 experienced contact lens wearers. Subjects wore a low Dk lens in one eye and a silicone hydrogel in the other and participated in four separate trials involving no lubricant (baseline), saline, and two commercially available lubricants of differing viscosity. The in-eye lubricants were used immediately following lens insertion and every 2 h postinsertion for a 6 h wear period. Postlens insertion comfort was significantly better for both lens types when lubricants or saline were used compared with no lubricant use. After 6 h lens wear, comfort was influenced by lens type and not by in-eye lubricant or saline use. Also after 6 h lens wear, less dryness sensation was reported for silicone hydrogel lenses when using lubricants but not saline. Although lubricant use does help reduce dryness symptoms with silicone hydrogel lens wear, there appears to be minimal longer-term benefit to comfort. Furthermore, increased lubricant viscosity did not lead to improved longer-term comfort.

  6. The effects of high-Dk rigid contact lens center thickness, material permeability, and blinking on the oxygen uptake of the human cornea.

    Science.gov (United States)

    Gardner, Hope Patterson; Fink, Barbara A; Mitchell, Lynn G; Hill, Richard M

    2005-06-01

    The human corneal oxygen uptake responses associated with the static (nonblinking) and dynamic (blinking) wear of five rigid gas-permeable materials with high oxygen permeabilities were determined for three different center thicknesses and compared with the responses for the normal open eye and severe hypoxic stress (static wear of polymethylmethacrylate). Corneal oxygen uptake rates were measured with a Clark-type polarographic electrode during two sessions with each of 10 human subjects. Measurements were made on the right eye for the normal open eye (air) and after 5 minutes of static and dynamic wear of polymethylmethacrylate and five rigid gas-permeable contact lens materials: Fluoroperm 92 (paflufocon A, Dk = 92), Fluoroperm 151 (paflufocon D, Dk = 151), 1992 Menicon SF-P (melafocon A, Dk = 102), 1995 Menicon SF-P (melafocon A, Dk = 159), and Menicon Z (tisilfocon A, Dk = 163-250). Lenses were manufactured in three different center thicknesses (0.12, 0.16, and 0.20 mm), with all other parameters remaining constant. Repeated-measures analysis of variance was used and included lens material (five levels), blinking condition (two levels), and lens thickness (three levels) as within-subject effects. Significant differences were found in corneal oxygen responses to lens material (p Dk rigid lens materials studied here, moderate changes in lens thickness or material permeability may result in modest differences in corneal hypoxic relief, whereas blinking results in no significant improvement to corneal oxygenation.

  7. [IOP measurement through frequent-replacement soft contact lenses].

    Science.gov (United States)

    Touboul, J

    2008-07-01

    Intraocular pressure (IOP) can be measured through soft contact lenses with an air-puff tonometer. These measurements seemed accurate for low-power negative lenses. For positive soft contact lenses, IOP is overestimated. The measurement of IOP through a soft contact lens is acceptable in clinical practice only for glaucoma screening. In glaucomatous patients or patients with ocular hypertension, IOP measurements should be performed without a contact lens. The main technique for IOP measurement remains Goldmann applanation tonometry.

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... A medical degree and many more years of training, for starters. A recent article from U.S. News and World Report explains what ophthalmologists are and how they can help you look after ... Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical ...

  9. Visual outcomes after implantation of a novel refractive toric multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Talita Shimoda

    2014-04-01

    Full Text Available Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC was -2.19 (SD: ± 0.53. After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001. Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence.

  10. Efficacy of different kinds of artificial tears treatment in patients with xerophthalmia after phacoemulsification combined with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Yu-Xia Ruan

    2017-09-01

    Full Text Available AIM: To explore efficacy of the different kinds of artificial tears treatment in patients with xerophthalmia after phacoemulsification combined with intraocular lens implantation.METHODS: Totally 280 patients(280 eyeswith xerophthalmia after operation in our hospital from January 2015 to June 2016 were selected. According to the different treatment methods, they were divided into control group(n=70; treated with tobramycin and dexamethasone eye ointment 3 times per day for 1wk, levofloxacin eye drops 3 times per day for 1wk, pranoprofen eye drops 4 times per day for 1mo, polyacrylic acid group(n=70; besides the treatment of control group, polyacrylic acid was used 4 times per for 1mo, polyethylene glycol group(n=70; besides the treatment of control group, polyethylene glycol was used 4 times per for 1moand sodium hyaluronate group(n=70; besides the treatment of control group, sodium hyaluronate was used 4 times per for 1mo. The tear film break up time(BUT, Schirmer Ⅰ test(SⅠt, symptoms of dry eye and corneal staining in four groups were observed. RESULTS:(1BUT: The BUT of the four groups significantly increased after treatment(PPPPPPPPPPP>0.05; sodium hyaluronate group was significant lower than other groups in corneal staining score at 3wk and 1mo after treatment(PCONCLUSION: Artificial tears in the treatment of xerophthalmia after cataract phacoemulsification combined with intraocular lens implantation has better clinical efficacy, which contains sodium hyaluronate may be the better than others.

  11. Effects of wearing a daily disposable lens on tear film: a randomised controlled trial.

    Science.gov (United States)

    Chong, Pamela Qin Yi; Yeo, Sharon; Too, Cheah Loon; Boo, Cynthia; Tong, Louis

    2016-05-01

    Contact lens-induced dry eye is commonly encountered, although its extent is not well documented with daily disposable lenses. A novel type of contact lens system incorporating moisturising agent (alginic acid) has been developed. The aim of this study was to evaluate the effect of wearing daily 2-hydroxyethyl methacrylate disposable contact lenses for seven days on tear stability, conjunctival and limbal redness and dry eye symptoms. Then, we aimed to determine whether lens solutions containing alginic acid had any influence on tear parameters. This was a seven-day parallel group double-masked clinical trial of previous contact lens wearers, where participants were randomly assigned to wearing SEED 1dayPure moisture contact lenses with (n = 15) or without alginic acid (n = 15). Tear lipid layer thickness (LLT), non-invasive tear break-up time (NIBUT), conjunctival redness, corneal fluorescein staining, tear break-up time and Schirmer I readings were measured. Symptom severity and frequency were evaluated and combined using a global score from visual analogue scales. The mean age and standard deviation of the participants was 25 ± 3.8 years. There were 24 females and six males. After reintroduction of contact lens wear for one week, there was significant improvement in the global symptom score; however, this may not be clinically significant. There were small and clinically insignificant changes in limbal and conjunctival hyperaemia but no significant changes in lipid layer thickness, Schirmer I and NIBUT in overall participants. The use of alginic acid in lens solutions did not affect these parameters compared to control lenses (p > 0.05). After seven days of wearing a modern daily disposable lens, there was no significant deterioration of tear function in a group of young contact lens wearers. In this short-term study, there was no evidence of significant benefit of lens solutions containing alginic acid used with HEMA lenses. © 2016 The Authors Clinical and

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far from the truth." ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by the ... Service For Advertisers For Media Ophthalmology Job Center © American ...

  13. Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Wojciech Lubiński

    2016-01-01

    Full Text Available Purpose. To evaluate the clinical outcomes after uncomplicated cataract surgery with implantation of an aspheric toric intraocular lens (IOL during a 6-month follow-up. Methods. Prospective study including 27 consecutive eyes of 18 patients (mean age: 66.1±11.4 years with a visually significant cataract and corneal astigmatism ≥ 0.75 D and undergoing uncomplicated cataract surgery with implantation of the Tecnis ZCT toric IOL (Abbott Medical Optics. Visual, refractive, and keratometric outcomes as well as IOL rotation were evaluated during a 6-month follow-up. At the end of the follow-up, patient satisfaction and perception of optical/visual disturbances were also evaluated using a subjective questionnaire. Results. At 6 months after surgery, mean LogMAR uncorrected (UDVA and corrected distance visual acuity (CDVA were 0.19±0.12 and 0.14±0.10, respectively. Postoperative UDVA of 20/40 or better was achieved in 92.6% of eyes. Mean refractive cylinder decreased significantly from −3.73±1.96 to −1.42±0.88 D (p<0.001, while keratometric cylinder did not change significantly (p=0.44. Mean absolute IOL rotation was 1.1±2.4°, with values of more than 5° in only 2 eyes (6.9%. Mean patient satisfaction score was 9.70±0.46, using a scale from 0 (not at all satisfied to 10 (very satisfied. No postoperative optical/visual disturbances were reported. Conclusion. Cataract surgery with implantation of the Tecnis toric IOL is an effective method of refractive correction in eyes with corneal astigmatism due to the good IOL positional stability, providing high levels of patient’s satisfaction.

  14. Molecular and morphological characterization of Acanthamoeba isolated from corneal scrapes and contact lens wearers in Argentina.

    Science.gov (United States)

    Casero, Rodolfo D; Mongi, Florencia; Laconte, Laura; Rivero, Fernando; Sastre, Dario; Teherán, Aníbal; Herrera, Giovanny; Ramírez, Juan David

    2017-10-01

    In this study, we describe the frequency of Acanthamoeba keratitis (AK) in patients that assisted in the Ophthalmology Department and determine the species/genotypes of free living amoebas (FLA) isolates. FLA from Corneal scrapes (CS) and contact lens (CL) wearers were studied by morphological and molecular characterization. A database was constructed with sociodemographic, clinical findings and history of use of CL variables. During January 2000 and September 2016 patients with corneal pathology admitted to the Ophthalmology Service of the University Hospital in Córdoba city, Argentina were included in the study. FLA were detected in 1.5% (11/739) and in 17% (11/65) of CS and CL analyzed respectively. FLA isolates from CL users evidenced an 80.9% of inappropriate lens maintenance, 4.8% (1/21) were not CL users that have been in contact with waters in outdoor environment and 14,3% (3/21) with no data about CL users. Acanthamoeba was confirmed in 100% and 82% of CS and LC respectively. The most frequent symptom associated with AK was red eye and photophobia. FLA from CS belonged to group II but 82% (9/11) and 18% (2/11) from CL belonged to group II and III respectively. T4 genotype and A. polyphaga species were detected in 100% of Acanthamoeba isolates. Poor CL hygiene practices, highlights the need for improved education about the severity of AK and consequences of improper CL hygiene. Genotype T4 detected in 100% of both CS and CL samples, consistently with previous findings indicating that this genotype is by far the most prevalent isolated from ocular infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Visual outcome with the Oculentis Mplus intraocular lens

    OpenAIRE

    Si-Yuan Liu; Xu Yang

    2017-01-01

    AIM: To evaluate the visual outcome of Oculentis Mplus intraocular lens(IOL).METHODS: Totally 20 eyes in 20 patients received phacoemulsification and Oculentis Mplus intraocular lens implantation were as test group, and 20 eyes(Aspira-aA IOL)were as control group. The following postoperative examinations were performed after operation for 3mo: uncorrected visual acuity of distance and near, refractive results, UBM examination, the rate of wearing spectacles and the complications. RESULTS: At ...

  16. Signal-enhancement reflective pulse oximeter with Fresnel lens

    Science.gov (United States)

    Chung, Shuang-Chao; Sun, Ching-Cherng

    2016-09-01

    In this paper, a new reflective pulse oximeter is proposed and demonstrated with implanting a Fresnel lens, which enhances the reflected signal. An optical simulation model incorporated with human skin characteristics is presented to evaluate the capability of the Fresnel lens. In addition, the distance between the light emitting diode and the photodiode is optimized. Compared with the other reflective oximeters, the reflected signal light detected by the photodiode is enhanced to more than 140%.

  17. Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays.

    Science.gov (United States)

    Park, Jihun; Kim, Joohee; Kim, So-Yun; Cheong, Woon Hyung; Jang, Jiuk; Park, Young-Geun; Na, Kyungmin; Kim, Yun-Tae; Heo, Jun Hyuk; Lee, Chang Young; Lee, Jung Heon; Bien, Franklin; Park, Jang-Ung

    2018-01-01

    Recent advances in wearable electronics combined with wireless communications are essential to the realization of medical applications through health monitoring technologies. For example, a smart contact lens, which is capable of monitoring the physiological information of the eye and tear fluid, could provide real-time, noninvasive medical diagnostics. However, previous reports concerning the smart contact lens have indicated that opaque and brittle components have been used to enable the operation of the electronic device, and this could block the user's vision and potentially damage the eye. In addition, the use of expensive and bulky equipment to measure signals from the contact lens sensors could interfere with the user's external activities. Thus, we report an unconventional approach for the fabrication of a soft, smart contact lens in which glucose sensors, wireless power transfer circuits, and display pixels to visualize sensing signals in real time are fully integrated using transparent and stretchable nanostructures. The integration of this display into the smart lens eliminates the need for additional, bulky measurement equipment. This soft, smart contact lens can be transparent, providing a clear view by matching the refractive indices of its locally patterned areas. The resulting soft, smart contact lens provides real-time, wireless operation, and there are in vivo tests to monitor the glucose concentration in tears (suitable for determining the fasting glucose level in the tears of diabetic patients) and, simultaneously, to provide sensing results through the contact lens display.

  18. Adhesion of Stenotrophomonas maltophilia, Delftia acidovorans, and Achromobacter xylosoxidans to Contact Lenses.

    Science.gov (United States)

    Vijay, Ajay Kumar; Willcox, Mark D P

    2017-09-26

    Contact lens cases become contaminated with microbes during use. We wished to compare the adhesion of uncommon bacterial contaminants isolated from lens cases to contact lenses with and without organic soil. Strains of Delftia acidovorans (001), Stenotrophomonas maltophilia (002 and 006), and Achromobacter xylosoxidans (001) isolated from contact lens cases (test strains) and Pseudomonas aeruginosa (Paer1) isolated from eyes at the time of infiltrative response (control strain) were used. Bacteria were grown and resuspended in phosphate-buffered saline (PBS) or 10% organic soil (heat-killed Saccharomyces cerevisiae resuspended in complement inactivated bovine serum). Two silicone hydrogel (senofilcon A and comfilcon A) and one hydrogel lens (etafilcon A) lens materials were used. Bacteria (1.0×10 and 1.0×10 colony-forming units/mL; CFU/mL) adhered to lenses for 24 hr and the numbers of bacteria adherent to each lens type (with and without organic soil) were estimated by culture. All the four test strains adhered in significantly greater numbers to contact lenses after incubation in inoculum prepared with organic soil compared with PBS-D. acidovorans 001 (0.7 log10 CFU; P0.05). Achromobacter xylosoxidans 001 (PBacteria that are commonly found in contact lens cases adhered to contact lenses in relatively high numbers in the presence of organic soil. This might indicate that a similar phenomenon occurs in the presence of tears. This may facilitate their transfer from the lens to the cornea and the production of corneal infiltrates.

  19. Trends in the use of silicone hydrogel contact lenses for daily wear.

    Science.gov (United States)

    Efron, Nathan; Morgan, Philip B

    2008-10-01

    Although the first silicone hydrogel contact lenses introduced onto the world contact lens market in 1999 held approval for both daily wear and extended wear use, the latter modality was promoted much more heavily by the manufacturers. The first silicone hydrogel lenses specifically promoted for daily wear were introduced in 2003. Data that we have gathered from annual contact lens fitting surveys demonstrate an immediate increase in market share whereby this lens type now represents more than one-third of soft lens fits in the United Kingdom. The success of this lens category is attributed to the health and safety benefits of silicone hydrogel materials and the positive impact of lens manufacturers by way of the effective marketing and distribution of these products.

  20. Estimating a just-noticeable difference for ocular comfort in contact lens wearers.

    Science.gov (United States)

    Papas, Eric B; Keay, Lisa; Golebiowski, Blanka

    2011-06-21

    To estimate the just-noticeable difference (JND) in ocular comfort rating by human, contact lens-wearing subjects using 1 to 100 numerical scales. Ostensibly identical, new contact lenses were worn simultaneously in both eyes by 40 subjects who made individual comfort ratings for each eye using a 100-point numerical ratings scale (NRS). Concurrently, interocular preference was indicated on a five-point Likert scale (1 to 5: strongly prefer right, slightly prefer right, no preference, slightly prefer left, strongly prefer left, respectively). Differences in NRS comfort score (ΔC) between the right and left eyes were determined for each Likert scale preference criteria. The distribution of group ΔC scores was examined relative to alternative definitions of JND as a means of estimating its value. For Likert scores indicating the presence of a slight interocular preference, absolute ΔC ranged from 1 to 30 units with a mean of 7.4 ± 1.3 (95% confidence interval) across all lenses and trials. When there was no Likert scale preference expressed between the eyes, absolute ΔC did not exceed 5 units. For ratings of comfort using a 100-point numerical rating scale, the inter-ocular JND is unlikely to be less than 5 units. The estimate for the average value in the population was approximately 7 to 8 units. These numbers indicate the lowest level at which changes in comfort measured with such scales are likely to be clinically significant.

  1. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

    Science.gov (United States)

    Arraes, Caroline; Endriss, Daniela; Lobato, Francisco; Arraes, João; Ventura, Marcelo

    2010-01-01

    To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

  2. Direct Laser Writing of Nanophotonic Structures on Contact Lenses.

    Science.gov (United States)

    AlQattan, Bader; Yetisen, Ali K; Butt, Haider

    2018-04-24

    Contact lenses are ubiquitous biomedical devices used for vision correction and cosmetic purposes. Their application as quantitative analytical devices is highly promising for point-of-care diagnostics. However, it is a challenge to integrate nanoscale features into commercial contact lenses for application in low-cost biosensors. A neodymium-doped yttrium aluminum garnet (Nd:YAG) laser (1064 nm, 3 ns pulse, 240 mJ) in holographic interference patterning mode was utilized to produce optical nanostructures over the surface of a hydrogel contact lens. One-dimensional (925 nm) and two-dimensional (925 nm × 925 nm) nanostructures were produced on contact lenses and analyzed by spectroscopy and angle-resolve measurements. The holographic properties of these nanostructures were tested in ambient moisture, fully hydrated, and artificial tear conditions. The measurements showed a rapid tuning of optical diffraction from these nanostructures from 41 to 48°. The nanostructures were patterned near the edges of the contact lens to avoid any interference and obstruction to the human vision. The formation of 2D nanostructures on lenses increased the diffraction efficiency by more than 10%. The versatility of the holographic laser ablation method was demonstrated by producing four different 2D nanopattern geometries on contact lenses. Hydrophobicity of the contact lens was characterized by contact angle measurements, which increased from 59.0° at pristine condition to 62.5° at post-nanofabrication. The holographic nanostructures on the contact lens were used to sense the concentration of Na + ions. Artificial tear solution was used to simulate the conditions in dry eye syndrome, and nanostructures on the contact lenses were used to detect the electrolyte concentration changes (±47 mmol L -1 ). Nanopatterns on a contact lens may be used to sense other ocular diseases in early stages at point-of-care settings.

  3. Reverse pupillary block associated with pigment dispersion syndrome after in-the-bag intraocular lens implantation.

    Science.gov (United States)

    Itagaki, Hideo; Kunikata, Toshio; Hiratsuka, Kentaro; Saito, Junichiro; Oshika, Tetsuro

    2013-12-01

    A 61-year-old man with high myopia who had received a systemic α1A-adrenoceptor antagonist had phacoemulsification and in-the-bag intraocular lens implantation in the right eye. One day postoperatively, marked pigment dispersion in the anterior chamber, posterior bowing of the iris, and iridodonesis were noted associated with a subsequent elevation in intraocular pressure (IOP). Pharmacological pupil dilation was effective in reducing pigment dispersion and IOP, and laser peripheral iridotomy was performed to alleviate posterior bowing of the iris. We hypothesize that dynamic changes in the aqueous humor flow by cataract surgery and latent flaccidity of the iris due to the systemic α1A-adrenoceptor antagonist caused reverse pupillary block. High myopia may be another risk factor for this complication. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Evaluation of Artisan aphakic intraocular lens in cases of pediatric aphakia with insufficient capsular support.

    Science.gov (United States)

    Gawdat, Ghada I; Taher, Sameh G; Salama, Marwa M; Ali, Adel A

    2015-06-01

    To evaluate the visual outcomes and complications after Artisan iris-claw lens implantation in aphakic children with insufficient capsular support. In this prospective, interventional noncontrolled study, aphakic eyes of consecutive patients >2 years of age with insufficient capsular support who underwent Artisan intraocular lens (IOL) implantation between June 2011 and December 2012 were followed for 1 year. Patients with anterior chamber depth IOL were included, 18 eyes with subluxated lens and 7 following trauma. The mean preoperative logMAR best-corrected visual acuity for traumatic aphakic patients was 0.95 ± 0.36; for patients with subluxation, 0.7 ± 0.26. Values improved at 1 year to 0.38 ± 0.15 (P IOL implantation for pediatric aphakia achieved a good visual outcome. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  5. Opaque iris claw lens in a phakic eye to correct acquired diplopia

    NARCIS (Netherlands)

    Landesz, M; Worst, JGF; Rij, GV; Houtman, WA

    1997-01-01

    A 25-year-old man had diplopia caused by abducens nerve paresis on both sides after cranial injury. Because of the patient's reports of persistent diplopia after surgical correction, a specially manufactured, tinted iris claw lens was implanted in the left eye, with the crystalline lens in situ.

  6. Outcomes of scleral-sutured conventional and aniridia intraocular lens implantation performed in a university hospital setting.

    Science.gov (United States)

    Lockington, David; Ali, Noor Q; Al-Taie, Rasha; Patel, Dipika V; McGhee, Charles N J

    2014-04-01

    To evaluate the outcomes of transscleral sutured posterior chamber intraocular lens (PC IOL) implantation. Public university hospital, Auckland, New Zealand. Retrospective case series. A modified no-touch transscleral sutured PC IOL implantation technique with a 1-piece monofocal IOL (Alcon CZ70BD) or an aniridia IOL (type 67G, Morcher) was assessed. Seventy-eight cases (80.8% men; 53.9% aphakic) were identified. The mean follow-up was 35.5 months and the mean age at surgery, 41 years±21 (SD). The preoperative corrected distance visual acuity (CDVA) was worse than 6/30 in 66.7%. Indications included ocular trauma (46.2%), nontraumatic crystalline lens subluxation (16.7%), post-complicated cataract surgery (10.3%), idiopathic IOL dislocation (10.3%), and congenital cataract/aphakia (10.3%). An aniridia IOL was required in 39.7% of eyes. There were no significant intraoperative complications in 74.4% of eyes. Postoperative complications included transient corneal edema (15.4%), wound leak requiring resuturing (7.7%), retinal detachment (7.7%), and cystoid macular edema (6.4%). One eye (1.3%) developed suture breakage-related late IOL dislocation. Overall, 91.3% of eyes had improved visual acuity or were within 1 line of the presenting CDVA. In eyes with a guarded prognosis, 34.8% achieved a CDVA of 6/12 or better and 43.5% a CDVA of 6/15 to 6/48. In the better prognosis group, 73.9% achieved a CDVA of better than 6/12 and all achieved better than 6/30. Scleral-sutured IOLs achieved good visual outcomes in a public hospital setting. The rate of complications was moderate in this series with a high proportion of severe ocular trauma and a large percentage of aniridia IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Comparison of the Results of Secondary Anterior Chamber and Secondary Scleral-Fixated Intraocular Lens Implantation in Complicated Phacoemulsification Cases

    Directory of Open Access Journals (Sweden)

    Nimet Yeşim Erçalık

    2014-03-01

    Full Text Available Objectives: To compare the visual prognosis and postoperative complication rates of secondary anterior chamber (AC IOL and scleralfixated (SF intraocular lenses (IOL after complicated phacoemulsification surgery. Materials and Methods: Thirty eyes of thirty patients were reviewed for this retrospective study. The patients with secondary AC IOL implantation formed group 1 (n=15, and the patients with secondary SF IOL implantation formed group 2 (n=15. Best-corrected visual acuity (BCVA with Snellen chart, biomicroscopic examination, intraocular pressure (IOP measurement with applanation tonometer, gonioscopy performed by Goldmann’s 3-mirror contact lens, and fundus examination were performed preoperatively in all patients. Results: There was no statistically significant difference in postoperative BCVA (p=0.492 and postoperative success (BCVA not changed or better postoperatively between the 2 groups (p=0.598. Postoperative success rate was 80% in group 1 and 93.7% in Group 2. The postoperative cylindrical power of the eyes did not differ significantly between the groups (p=0.220. The postoperative complications in group 1 were as follows: transient corneal edema in 5 eyes, transient IOP elevation in 2 eyes, postoperative fibrinous reaction in the anterior chamber in one eye, late-onset secondary glaucoma in one eye, hyphema in one eye, cystoid macular edema in one eye, vitreous prolapse into the anterior chamber in one eye, and IOL malposition in one eye. The postoperative complications in group 2 were as follows: transient corneal edema in 3 eyes, vitreous prolapse into the anterior chamber in 2 eyes, IOL malposition in 2 eyes, transient IOP elevation in one eye, and retinal detachment in one eye. Conclusion: In this study, both IOL types were observed to be preferable in cases without adequate capsular support following complicated cataract surgery. However, further studies with large numbers of patients are needed to define the best choice

  8. Practitioner Perceptions of Patients Wearing Decorative Contact Lenses Purchased Through Unauthorized Sellers.

    Science.gov (United States)

    Gaiser, Hilary; Ho, Connie; Janier, Nicole; Wee, Amy; Johnson, Catherine; Watanabe, Ronald

    2017-03-01

    To describe practitioner experiences regarding ocular complications in patients wearing decorative contact lenses, and to investigate the compliance of unauthorized distributors of decorative contact lenses to current Food and Drug Administration (FDA) and Federal Trade Commission (FTC) regulations. Also, to provide data to support a more targeted public health approach to reducing the incidence of illegal contact lens sales and associated ocular complications. An institutional review board-approved online survey was distributed through mass email to a list of 98 optometrists in the Boston, MA area. Concurrently, an empirical evaluation of independent, online decorative contact lens sellers who were not associated with FDA-approved contact lens manufacturers was performed to determine their adherence to FDA and FTC guidelines. The first 18 noncoincidental websites that resulted from a Google search for "costume contact lens sellers" and "cosmetic contact lens sellers" were examined as to the brands and parameters of lenses being sold, whether or not a valid prescription was required or verified, and if consumer education was provided. Twenty-two optometrists completed the online survey. Seventy-seven percent of respondents reported having patients with complications from decorative contact lenses that were purchased both legally and illegally. The most common age group for complications was 18 to 25 years (61%). One third of complications were seen in first-time lens wearers, half of whom never received proper care instructions or were unaware that care instructions existed. One quarter of the lenses were purchased illegally with unlicensed stores being the most common place of purchase. Of the 18 online sites examined, 72% of sellers failed to adhere to FTC and FDA regulations. A significant number of individuals who obtain contact lenses illegally from unauthorized sources are young adults. Most unauthorized sellers reviewed did not adhere to the proper protocol

  9. Subluxation of the crystalline lens: a no-ring approach.

    Science.gov (United States)

    Rodrigues, Antonio Carlos L; Trivedi, Rupal H; Wilson, M Edward

    2012-01-01

    To report the surgical technique and outcomes of a no-ring approach to posterior chamber intraocular lens (IOL) implantation in children and young adults with subluxation of the crystalline lens. A three-piece 5.5-mm hydrophobic acrylic IOL was implanted in which the optic and one haptic were inside the capsular bag and the other haptic was in the ciliary sulcus. The implantations were done in 13 eyes of 10 patients with lens subluxation. One haptic was fixated in the ciliary sulcus by passing it through an operculum-shaped opening in the capsular bag edge, made between 2 and 3 clock hours, clockwise from the middle point of the subluxated area. The mean age of the 10 patients was 12.61 ± 8.04 years and the mean follow-up was 21.38 ± 11.29 months. The mean preoperative and postoperative best-corrected visual acuity (BCVA) was 1.15 ± 0.58 and 0.37 ± 0.17 logarithm of the minimum angle of resolution, respectively, in 11 measured eyes. The postoperative BCVA was 20/40 or better in 4 eyes (36.36%), between 20/40 and 20/60 in 6 eyes (54.54%), and between 20/80 and 20/100 in 1 eye (9.09%). The BCVA improved in all eyes. Postoperative IOL decentration between 1.0 and 1.5 mm occurred in 3 of 13 eyes (23.08%). The results indicate that the no-ring technique allows centration of an IOL implanted into a subluxated capsular bag without using capsule tension rings. Copyright 2012, SLACK Incorporated.

  10. Myopia, contact lens use and self-esteem.

    Science.gov (United States)

    Dias, Lynette; Manny, Ruth E; Weissberg, Erik; Fern, Karen D

    2013-09-01

    To evaluate whether contact lens (CL) use was associated with self-esteem in myopic children originally enrolled in the Correction of Myopia Evaluation Trial (COMET), that after 5 years continued as an observational study of myopia progression with CL use permitted. Usable data at the 6-year visit, one year after CL use was allowed (n = 423/469, age 12-17 years), included questions on CL use, refractive error measurements and self-reported self-esteem in several areas (scholastic/athletic competence, physical appearance, social acceptance, behavioural conduct and global self-worth). Self-esteem, scored from 1 (low) to 4 (high), was measured by the Self-Perception Profile for Children in participants under 14 years or the Self-Perception Profile for Adolescents, in those 14 years and older. Multiple regression analyses were used to evaluate associations between self-esteem and relevant factors identified by univariate analyses (e.g., CL use, gender, ethnicity), while adjusting for baseline self-esteem prior to CL use. Mean (±S.D.) self-esteem scores at the 6-year visit (mean age = 15.3 ± 1.3 years; mean refractive error = -4.6 ± 1.5 D) ranged from 2.74 (± 0.76) on athletic competence to 3.33 (± 0.53) on global self-worth. CL wearers (n = 224) compared to eyeglass wearers (n = 199) were more likely to be female (p self-esteem or CL use. COMET participants who chose to wear CLs after 5 years of eyeglass use had higher self-esteem compared to those who remained in glasses both preceding and following CL use. This suggests that self-esteem may influence the decision to wear CLs and that CLs in turn are associated with higher self-esteem in individuals most likely to wear them. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  11. Intra-ocular lens implantation after vitreous loss.

    Directory of Open Access Journals (Sweden)

    Shah N

    1991-10-01

    Full Text Available Vitreous loss is a dreaded complication of cataract surgery, especially so with IOL implant which then may have to be abandoned. Thirty three cases of IOL implants, either anterior chamber or posterior chamber, after vitreous loss done in the past 3 years were studied. Of these, 18 (55% had a final visual acuity of 6/18 or better and none was worse than 6/60. The postoperative complications and findings and a review of literature are discussed.

  12. Refractive Lens Exchange with Multifocal Intraocular Lens for Treatment of Chronic Intermittent Spasm of the Near Reflex

    Directory of Open Access Journals (Sweden)

    Guy Sallet

    2017-12-01

    Full Text Available We report the case of an emmetropic 32-year-old female with decreased uncorrected visual acuity and diplopia due to intermittent episodes of spasm of the near reflex. Neurologic, general, and ophthalmic examination could not find an organic cause. Attempts at spontaneous recovery, psychogenic therapy, and cycloplegic therapy were unsuccessful and the symptoms persisted for almost 5 years, leading to psychogenic distress. Final treatment with refractive lens exchange and implantation of a toric trifocal intraocular lens resolved the spasm of the near reflex, resulting in an uncorrected distance and near visual acuity of 20/20.

  13. Implante intra-ocular de lentes dobráveis "piggyback" em paciente portador de catarata congênita no primeiro ano de vida: relato de caso Piggyback foldable intraocular lens implant in patient with congenital cataract in the first year of life: case report

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2004-12-01

    Full Text Available No presente relato os autores descrevem um caso de catarata congênita unilateral tratada cirurgicamente com implante intra-ocular de lentes dobráveis "piggyback", ainda não descrito na literatura nacional. São analisadas as diferenças e semelhanças com outros casos descritos na literatura.The authors report a case of congenital cataract, which was treated with piggyback foldable intraocular lens implant, not described in the Brazilian literature. The differences and similarities are analyzed with other reported cases in the literature.

  14. Optical and visual performance of aspheric soft contact lenses.

    Science.gov (United States)

    Efron, Suzanne; Efron, Nathan; Morgan, Philip B

    2008-03-01

    This study was conducted to investigate whether aspheric design soft contact lenses reduce ocular aberrations and result in better visual acuity and subjective appreciation of clinical performance compared with spherical soft contact lenses. A unilateral, double-masked, randomized and controlled study was undertaken in which ocular aberrations and high and low contrast logMAR visual acuity were measured on myopic subjects who wore aspheric design (Biomedics 55 Evolution, CooperVision) and spherical design (Biomedics 55, CooperVision) soft contact lenses. Ten subjects who had about -2.00 D myopia wore -2.00 D lenses and 10 subjects who had about -5.00 D myopia wore -5.00 D lenses. Measurements were made under photopic and mesopic lighting conditions. Subjects were invited to grade comfort, vision in photopic and mesopic conditions, and overall impression with the two lens types on 100 unit visual analogue scales. There was no significant difference in high contrast or low contrast visual acuity between the two lens designs of either power under photopic or mesopic conditions. Both lens designs displayed lower levels of spherical aberration compared with the "no lens" condition under photopic and mesopic light levels (p designs. There were no statistically significant differences in subjective appreciation of clinical performance between lens designs or lens powers. At least with respect to the brand of lenses tested, the fitting of aspheric design soft contact lenses does not result in superior visual acuity, aberration control, or subjective appreciation compared with equivalent spherical design soft contact lenses.

  15. High-Dk piggyback contact lenses over Intacs for keratoconus: a case report.

    Science.gov (United States)

    Smith, Kyle A; Carrell, James D

    2008-07-01

    The authors describe a case of a keratoconic patient with Intacs fitted with a high-Dk piggyback contact lens system. A 41-year-old man presented to the clinic 1 week after Intacs surgery for keratoconus with complaints of poor visual acuity (VA) and monocular polyopia OU. The patient was corrected to 20/30 in both eyes with rigid gas permeable contact lenses but could not tolerate the lenses for more than 8 hours OD and 2 hours OS. The patient was then successfully fit with a high-Dk piggyback contact lens system. The patient was able to wear the piggyback contact lenses comfortably 12 to 18 hours per day and was corrected to 20/25 OD, 20/30 OS, and 20/20 OU. Patients with Intacs for keratoconus may require a combination of soft and rigid contact lenses for the best possible VA. Contact lens fitting with a high-Dk piggyback contact lens system can provide optimal comfort, corneal health, and VA for patients with Intacs for keratoconus.

  16. Comparison of Bigbag and Rayner620H intraocular lens in cataract surgeries in high myopia patients

    Directory of Open Access Journals (Sweden)

    Zhan-Jiang Liu

    2016-01-01

    Full Text Available AIM:To investigate the effects of Bigbag and Rayner620H intraocular lens in cataract surgeries in high myopia patients. METHODS:Seventy-seven patients(128 eyeswere treated by phacoemulsification combined with intraocular lens implantation from January 2014 to March 2015 in our hospital. Thirty-nine patients(65 eyeswere treated with Bigbag intraocular lens, 38 cases(63 eyeswere treated with Rayner620H. The best corrected visual acuity(BCVAdistribution, the actual refractive value, the difference between predictive refractive value and actual refractive value and complications were measured and recorded in the two groups at 1mo after surgeries. RESULTS:The difference between the two groups on BCVA are statistically significant(PWilcoxon rank sum test. The differences between predictive refractive value and actual refractive value of the two groups were statistically significant(PPCONCLUSION:The effect of Bigbag intraocular lens for patients with phacoemulsification and intraocular lens implantation is good, and it can reduce the risk of complications.

  17. The low-field permanent magnet electrostatic plasma lens

    International Nuclear Information System (INIS)

    Goncharov, A.; Gorshkov, V.; Maslov, V.; Zadorozhny, V.; Brown, I.

    2004-01-01

    We describe the status of ongoing research and development of the electrostatic plasma lens as used for the manipulation of high current broad beams of heavy ions of moderate energy. In some collaborative work at Lawrence Berkeley National Laboratory the lens was used to good effect for carrying out high dose ion implantation processing. In the process of this work a very narrow range of low magnetic field was found for which the ion-optical characteristics of the lens improved markedly. Subsequent theoretical analysis and computer modeling has led to an understanding of this phenomenon. These serendipitous results open up some attractive possibilities for the development of a new compact and low cost plasma lens based on permanent magnets rather than on current-driven field coils surrounding the lens volume. The development of this kind of lens, including both very low noise and minimal spherical aberration effects, may lead to a tool suitable for use in the injection beam lines of high current heavy ion linear accelerators. Here we briefly review the lens fundamentals, some characteristics of focusing heavy ion beams at low magnetic fields, and summarize recent theoretical and experimental developments, with emphasis on the relevance and suitability of the lens for accelerator injection application

  18. Modelling the metal–semiconductor band structure in implanted ohmic contacts to GaN and SiC

    International Nuclear Information System (INIS)

    Pérez-Tomás, A; Fontserè, A; Placidi, M; Jennings, M R; Gammon, P M

    2013-01-01

    Here we present a method to model the metal–semiconductor (M–S) band structure to an implanted ohmic contact to a wide band gap semiconductor (WBG) such as GaN and SiC. The performance and understanding of the M–S contact to a WBG semiconductor is of great importance as it influences the overall performance of a semiconductor device. In this work we explore in a numerical fashion the ohmic contact properties to a WBG semiconductor taking into account the partial ionization of impurities and analysing its dependence on the temperature, the barrier height, the impurity level band energy and carrier concentration. The effect of the M–S Schottky barrier lowering and the Schottky barrier inhomogeneities are discussed. The model is applied to a fabricated ohmic contact to GaN where the M–S band structure can be completely determined. (paper)

  19. Lens subluxation grading system: predictive value for ectopia lentis surgical outcomes

    Directory of Open Access Journals (Sweden)

    Mauro Waiswol

    2009-03-01

    Full Text Available Objective: To present a classification system to grade ectopia lentis and to assess its usefulness as a predictor for surgical outcomes. Methods: Fifty-one eyes of 28 patients with either simple (19 patients or Marfan syndrome-associated ectopia lentis (nine patients with variable degrees of subluxation were operated on. Lens subluxation intensity was graded according to the lens subluxation grading system (LSGS from grade 1 (lens on the whole pupillary area up to grade 4 (lens absent from the pupillary area. Thirty eyes underwent cataract extraction (“dry” aspiration with endocapsular ring and in-the-bag intraocular lens (IOL implantation. Twenty-one eyes underwent cataract extraction (“dry” aspiration with scleral fixation of the IOL. The predictive value of the LSGS was assessed by analyzing the post-operative outcomes, including visual acuity (VA, endothelial cell loss, and complications for each grade on the grading system. Rresults: Patients were classified into grade 1 (19.6%, grade 2 (51% and grade 3 (29.4%. Post-operative VA was lower for eyes with larger degrees of subluxation. The higher the subluxation grade, the higher the endothelial cell loss, as well as, the frequency of vitreous loss and surgical time. Higher subluxation grades prevented optimal surgical outcomes with endocapsular ring and in-the-bag IOL implantation. Cconclusions: The LSGS provides an estimate of the surgical success of ectopia lentis. Adequate standardization of lens subluxation is crucial for understanding studies dealing with the surgical correction of this disorder.

  20. Differences in daily disposable circle lens performance characteristics

    Directory of Open Access Journals (Sweden)

    Schafer JM

    2014-04-01

    Full Text Available Jeffery M Schafer, William T Reindel, Marjorie J Rah, Osbert Chan, Lening Zhang Bausch & Lomb Incorporated, Rochester, NY, USA Purpose: The purpose of this evaluation was to compare the performance characteristics of two cosmetically tinted contact lenses in the circle lens category that differ in lens design, lens material, and pigment print pattern: etafilcon A (1-Day Acuvue Define; Johnson & Johnson Vision Care and hilafilcon B (Naturelle; Bausch & Lomb Incorporated. Methods: Two hundred Asian subjects (400 eyes were enrolled in this 1-month parallel, bilateral, randomized study at ten investigative sites. Study lenses were dispensed at a screening/dispensing visit, and follow-up visits occurred at 2 weeks and 1 month. Lenses were worn on a daily disposable basis. Fit characteristics were evaluated at each visit, and slit-lamp evaluations were completed at each follow-up visit. Results: Of the 200 patients enrolled, 172 (344 eyes completed the study. The proportion of eyes with fully centered lenses was statistically significantly higher for the hilafilcon B group at the 2-week and 1-month visits, P<0.05. Over all visits, 0.6% of hilafilcon B eyes demonstrated incomplete corneal coverage, whereas for the etafilcon A group, 8.5% of eyes demonstrated incomplete corneal coverage and/or edge lift. The proportion of eyes with adequate lens movement was statistically significantly higher for the hilafilcon B group, P<0.05. Over all visits, none of the hilafilcon B eyes was reported to have excessive movement, whereas for etafilcon A lenses, 10.2% of eyes were reported to have excessive movement. Conclusions: Etafilcon A lenses were significantly less likely to be fully centered and significantly more likely to have incomplete corneal coverage and/or edge lift compared with the hilafilcon B lenses. Keywords: cosmetic contact lens, circle contact lens

  1. Safety assessment of a new single-use small-incision injector for intraocular lens implantation.

    Science.gov (United States)

    Satanovsky, Alexandra; Ben-Eliahu, Shmuel; Apple, David J; Kleinmann, Guy

    2011-07-01

    To evaluate the safety of a new injector, the Raysert R-INJ-04/18, for implantation of the C-flex intraocular lens (IOL). Ophthalmology Department, Kaplan Medical Center, Rehovot, Israel. Experimental study. Sixty IOLs were subdivided into 2 equally sized groups. Group A IOLs were injected using the established R-INJ-04 injector, and those in Group B were injected with the new injector. The IOLs were injected into a Petri dish. Subsequently, all IOLs and injectors were evaluated macroscopically and microscopically and then photographed under light microscopy (LM). Two IOLs in each group were randomly chosen and sent for evaluation by scanning electron microscopy (SEM) and energy dispersive analysis of x-ray. All remaining IOLs were sent for power and modulation transfer function (MTF) analysis. All Group B IOLs were successfully injected without evident signs of scratching, cracks, or deposits on LM and SEM examination. In Group A, findings were confined to a singular incidence of a small deposit detected on the periphery of the posterior optical surface of the IOL, with corresponding findings detected on the injector nozzle. No signs of scratching, cracks, or deposits were found in the rest of the IOLs or injectors. The power and MTF analyses were within the normal range for all IOLs. The new 1.8 mm external diameter soft-tipped injector for 2.4 to 2.2 mm incisions was shown to be safe for the implantation of the C-flex 21.0 diopter IOL. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Condições de adaptação e venda de lentes de contato em óticas do estado de São Paulo Conditions of contact lens fitting and sale by optician stores São Paulo state

    Directory of Open Access Journals (Sweden)

    Andrea Cotait Kara José

    2001-10-01

    indicação de tratamento. Em apenas 15 (13,39%, o profissional orientou quanto à possível sintomatologia de perigo e em 13 (11,61%, preocupou-se com doenças que contra-indicassem o uso de LC. Em 105 (93,75% óticas, a orientação foi insuficiente em relação à higiene com as LC, às horas de uso e à possibilidade de pernoite. Conclusão: Das 198 óticas pesquisadas, 61,11% vendem lentes de contato, sendo que em 92,56% não foram solicitadas receitas médicas; 14,88% não fizeram qualquer tipo de teste de tolerância e as óticas restantes (85,12% fizeram testes normalmente insuficientes para detecção de alterações induzidas por LC. Não houve preocupação com contra-indicações, sinais e sintomas de perigo nem avaliação de possíveis complicações pela presença das LC e conduta em caso de sua ocorrência, além dos cuidados mínimos de higiene durante o teste de tolerância. O profissional responsável pela adaptação (autodenominado contatólogo, balconista, ótico; ou oftalmologista não forneceu orientação adequada sobre o uso e, em muitos casos, não deu orientação em relação à higiene.Purpose: To evaluate contact lens (CL adaptation and sales in optician stores of 4 cities in São Paulo State, Brazil. Methods: A study was performed in view of the answers to a questionnaire applied by four medical students to optician stores selling contact lenses in four cities of the state of São Paulo. The researchers evaluated the need of medical prescriptions for contact lens sales, the specialist in charge of selling and/or adapting contact lenses, the types of lenses sold/adapted, the equipment used in the contact lens tolerance test, the patient's behavior facing contact lens complications during adaptation or during its use; the information given about possible signs and symptoms of risk and the patient's hygiene, as well as the number of hours of contact lens wear and their wearing during sleep. Results: Of the 198 investigated optician stores

  3. Radiation safety and protection of close contacts from radiators after implantation of radioactive 125I seeds

    International Nuclear Information System (INIS)

    Sui Aixia; Li Jianmin; Tang Fulong; Zhang Hongtao; Ren Ju'na; Pang Linbin; Xia Haishui; Gao Zhen; Wu Lili; Wang Juan

    2012-01-01

    Objective: To study the effective dose and precaution time of the irradiation of the close contact from the radiators who underwent implantation of radioactive 125 I seeds so as to guide scientifically people how to avoid radiation damage. Methods: Twenty patients with different types of cancer underwent implantation of radioactive 125 I seeds with the median value of implantation depth of 2.16 cm. Within 24 h after the operations the dose rates 30 cm and 100 cm from the skin were measured with pocket-size radiometer so as to imitate the situations of the close contacts. The effective doses and precaution times of different persons were calculated according to relevant formula. Results: The dose rate a person received at the same time points (1, 54, 78, and 109 d, respectively) decreased along with the increase of the distance from the skin (t=5.962, 5.961, 5.961, 5.962, P<0.05), and the dose rate a person received at the same distance from the skin decreased along with the extension of time (30 cm: t=6.236, 6.236, 6.235, P<0.05; 100 cm: t=7.310, 7.315, 7.314, P<0.05). At different time points, the dose rates at 30 cm distance point were all significant higher than those at the 100 cm point (P <0.05). The adult living together, minors and pregnant women sharing the room, colleagues,adults who slept together with the patients began to reach the 50% dose constraint values 0, 54, 78 and 109 days after the operation. Conclusions: After their precaution time, it's safe to contact with the patients for the groups; otherwise, it's necessary to take some protect works within the precaution time. (authors)

  4. Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses.

    Science.gov (United States)

    Kim, Eon; Bakaraju, Ravi C; Ehrmann, Klaus

    2016-01-01

    To evaluate the repeatability of power profiles measured on NIMO TR1504 (Lambda-X, Belgium) and investigate the effects of lens decentration on the power profiles for single vision (SV), bifocal (BF) and multifocal (MF) contact lenses. Accuracy of the sphere power was evaluated using single vision BK-7 calibration glass lenses of six minus and six plus powers. Three SV and four BF/MF contact lenses - three lenses each, were measured five times to calculate the coefficients of repeatability (COR) of the instrument. The COR was computed for each chord position, lens design, prescription power and operator. One lens from each type was measured with a deliberate decentration up to ±0.5mm in 0.1mm steps. For all lenses, the COR varied across different regions of the half-chord position. In general, SV lenses showed lower COR compared to the BF/MF group lenses. There were no noticeable trends of COR between prescription powers for SV and BF/MF lenses. The shape of the power profiles was not affected when lenses were deliberately decentered for all SV and PureVision MF lenses. However, for Acuvue BF lenses, the peak to trough amplitude of the power profiles flattened up to 1.00D. The COR across the half-chord of the optic zone diameter was mostly within clinical relevance except for the central 0.5mm half-chord position. COR were dependent on the lens type, whereby BF/MF group produced higher COR than SV lenses. The effects of deliberate decentration on the shape of power profiles were pronounced for lenses where the profiles had sharp transitions of power. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  5. Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens.

    Science.gov (United States)

    García-Bella, Javier; Martínez de la Casa, José M; Talavero González, Paula; Fernández-Vigo, José I; Valcarce Rial, Laura; García-Feijóo, Julián

    2018-01-01

    To establish the changes produced after implantation of a trifocal intraocular lens (IOL) on retinal nerve fiber layer measurements performed with Fourier-domain optical coherence tomography (OCT). This prospective study included 100 eyes of 50 patients with bilateral cataract in surgical range, no other associated ocular involvement, refractive errors between +5 and -5 spherical diopters, and less than 1.5 D of corneal astigmatism. The eyes were operated by phacoemulsification with implantation of 2 different trifocal IOLs (FineVision and AT LISA tri 839MP) in randomized equal groups. Cirrus OCT and Spectralis OCT were performed before surgery and 3 months later. Both analyzed the thickness of the nerve fiber layer and thickness divided by quadrants (6 in case of Spectralis and 4 in case of Cirrus HD). The mean age of patients was 67.5 ± 5.8 years. The global nerve fiber layer thickness measured with Spectralis OCT was 96.77 μm before surgery and 99.55 μm after. With Cirrus OCT, the global thickness was 85.29 μm before surgery and 89.77 μm after. Statistically significant differences in global thickness measurements between preimplantation and postimplantation of the IOL were found with both OCT in the 2 groups. Statistically significant differences were also found in temporal and superior quadrants. The implantation of a diffractive trifocal IOL alters the results of the optic nerve fiber layer on Fourier-domain OCT in these patients, which should be taken into account in the posterior study of these patients.

  6. Tuning of Schottky Barrier Height at NiSi/Si Contact by Combining Dual Implantation of Boron and Aluminum and Microwave Annealing

    Directory of Open Access Journals (Sweden)

    Feng Sun

    2018-03-01

    Full Text Available Dopant-segregated source/drain contacts in a p-channel Schottky-barrier metal-oxide semiconductor field-effect transistor (SB-MOSFET require further hole Schottky barrier height (SBH regulation toward sub-0.1 eV levels to improve their competitiveness with conventional field-effect transistors. Because of the solubility limits of dopants in silicon, the requirements for effective hole SBH reduction with dopant segregation cannot be satisfied using mono-implantation. In this study, we demonstrate a potential solution for further SBH tuning by implementing the dual implantation of boron (B and aluminum (Al in combination with microwave annealing (MWA. By using such a method, not only has the lowest hole SBH ever with 0.07 eV in NiSi/n-Si contacts been realized, but also the annealing duration of MWA was sharply reduced to 60 s. Moreover, we investigated the SBH tuning mechanisms of the dual-implanted diodes with microwave annealing, including the dopant segregation, activation effect, and dual-barrier tuning effect of Al. With the selection of appropriate implantation conditions, the dual implantation of B and Al combined with the MWA technique shows promise for the fabrication of future p-channel SB-MOSFETs with a lower thermal budget.

  7. A Laboratory Assessment of Factors That Affect Bacterial Adhesion to Contact Lenses

    OpenAIRE

    Dutta, Debarun; Willcox, Mark DP

    2013-01-01

    Adhesion of pathogenic microbes, particularly bacteria, to contact lenses is implicated in contact lens related microbial adverse events. Various in vitro conditions such as type of bacteria, the size of initial inoculum, contact lens material, nutritional content of media, and incubation period can influence bacterial adhesion to contact lenses and the current study investigated the effect of these conditions on bacterial adhesion to contact lenses. There was no significant difference in num...

  8. Invited review article: the electrostatic plasma lens.

    Science.gov (United States)

    Goncharov, Alexey

    2013-02-01

    The fundamental principles, experimental results, and potential applications of the electrostatic plasma lens for focusing and manipulating high-current, energetic, heavy ion beams are reviewed. First described almost 50 years ago, this optical beam device provides space charge neutralization of the ion beam within the lens volume, and thus provides an effective and unique tool for focusing high current beams where a high degree of neutralization is essential to prevent beam blow-up. Short and long lenses have been explored, and a lens in which the magnetic field is provided by rare-earth permanent magnets has been demonstrated. Applications include the use of this kind of optical tool for laboratory ion beam manipulation, high dose ion implantation, heavy ion accelerator injection, in heavy ion fusion, and other high technology.

  9. Lens Design Using Group Indices of Refraction

    Science.gov (United States)

    Vaughan, A. H.

    1995-01-01

    An approach to lens design is described in which the ratio of the group velocity to the speed of light (the group index) in glass is used, in conjunction with the more familiar phase index of refraction, to control certain chromatic properties of a system of thin lenses in contact. The first-order design of thin-lens systems is illustrated by examples incorporating the methods described.

  10. An improved diagnostic contact lens.

    Science.gov (United States)

    Smith, R J

    1979-01-01

    Modification of a standard Goldmann goniolens by reducing the curvature of the contact surface to 8.5 mm radius of curvature (from the standard curvature of 7.4 mm) enabled gonioscopy to be carried out without the nuisance of air bubbles. Images PMID:465424

  11. The rectenna design on contact lens for wireless powering of the active intraocular pressure monitoring system.

    Science.gov (United States)

    Cheng, H W; Jeng, B M; Chen, C Y; Huang, H Y; Chiou, J C; Luo, C H

    2013-01-01

    This paper proposed a wireless power harvesting system with micro-electro-mechanical-systems (MEMS) fabrication for noninvasive intraocular pressure (IOP) measurement on soft contact lens substructure. The power harvesting IC consists of a loop antenna, an impedance matching network and a rectifier. The proposed IC has been designed and fabricated by CMOS 0.18 um process that operates at the ISM band of 5.8 GHz. The antenna and the power harvesting IC would be bonded together by using flip chip bonding technologies without extra wire interference. The circuit utilized an impedance transformation circuit to boost the input RF signal that improves the circuit performance. The proposed design achieves an RF-to-DC conversion efficiency of 35% at 5.8 GHz.

  12. Evaluation of an interlaced triple procedure: penetrating keratoplasty, extracapsular cataract extraction, and nonopen-sky intraocular lens implantation.

    Science.gov (United States)

    Yang, Shuo; Wang, Bin; Zhang, Yangyang; Zhai, Hualei; Wang, Junyi; Wang, Shuang; Xie, Lixin

    2017-09-01

    To evaluate an interlaced triple procedure that involved penetrating keratoplasty (PKP), extracapsular cataract extraction (ECCE) using diathermy capsulotomy, and nonopen-sky intraocular lens (IOL) implantation.This retrospective study involved data from 34 patients who were diagnosed with severe corneal opacities and cataracts. These patients were divided into an interlaced procedure group (21 patients) and a traditional procedure group (13 patients). In the interlaced group, the method of continuous curvilinear capsulorhexis (CCC) was completed via diathermy capsulotomy. The donor corneal button was sutured at 8 positions (at equal intervals) using 10-0 nylon sutures, and the IOL was inserted into the capsular bag using a closed anterior chamber approach at the 10:30 to 12 o'clock positions between the sutures. In the traditional group, CCC was completed using side-port capsular forceps, and the IOL was implanted using an open anterior chamber approach.In the interlaced group, the CCC, open-sky, and total operation times were significantly shorter than in the traditional group (P < .05). Neither the best-corrected visual acuity (BCVA) nor corneal endothelial cell density was significantly different between the groups at 1 and 6 months after the operation.This interlaced triple procedure for the treatment of corneal diseases with cataracts appears to be feasible and practical.

  13. Deposition of lipid, protein, and secretory phospholipase A2 on hydrophilic contact lenses.

    Science.gov (United States)

    Mochizuki, Hiroshi; Yamada, Masakazu; Hatou, Shin; Kawashima, Motoko; Hata, Seiichiro

    2008-01-01

    Recent studies have shown that low tear phospholipid levels are associated with tear film instability in hydrophilic contact lens wearers. The concentration of secretory phospholipase A2 (sPLA2), the enzyme that hydrolyzes phospholipids, in tears is known to exceed the levels found in serum by four orders of magnitude. This study was performed to determine the levels of sPLA2 from the deposition on two different frequent-replacement contact lens materials. Polymacon and etafilcon A contact lenses worn for 2 weeks by 16 experienced contact lens wearers were used for the analysis. Total lipids were determined by the sulfo-phospho-vanillin reaction. Phospholipids in lipid extracts were estimated by phosphorus determination with ammonium molybdate through enzymatic digestion. Total protein was measured by bicinchoninic acid analysis. Double-antibody sandwich enzyme-linked immunosorbent assay was used to determine sPLA2 concentrations. Total lipid deposition was found to be greater in the polymacon group (66.3+/-16.3 microg/lens) than in the etafilcon A group, although phospholipids were not detected in either group. The etafilcon A group had greater deposition of protein (3.7+/-0.7 mg/lens) than the polymacon group had. The etafilcon A group deposited statistically significantly more group IIa sPLA2 (1.1+/-0.3 microg/lens) than the polymacon group (0.07+/-0.04 microg/lens) did (P<0.001). There was a significant difference in the lipid and protein deposition profiles in the two lenses tested. A significant amount of sPLA2 in the deposition on contact lenses may play a role in tear film instability in hydrophilic contact lens wearers.

  14. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  15. Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2016-05-01

    Full Text Available Kjell G Gundersen,1 Rick Potvin21IFocus Øyeklinikk AS, Haugesund, Norway; 2Science in Vision, Akron, NY, USAPurpose: To compare the visual acuity (VA and quality of vision between bilateral implantation of a trifocal intraocular lens (IOL and blended bifocal IOLs with an intermediate add in the dominant eye and a near add in the nondominant eye.Patients and methods: Patients with either trifocal or blended bifocal IOLs implanted were recruited after surgery. Subjects returned for a single diagnostic visit between 3 and 24 months after surgery. VA was tested at various distances, including low-contrast acuity and acuity at their preferred reading distance. A binocular defocus curve was obtained, and subjective visual function and quality of vision were evaluated.Results: Twenty-five trifocal subjects and 30 blended bifocal subjects were enrolled. There were no significant differences in low-contrast acuity, preferred reading distance, or acuity at that reading distance. Binocular vision at 4 m, 60 cm, and 40 cm was not statistically significantly different. The trifocal provided statistically significantly better visual acuity (P<0.05 at vergences from -0.5 to -1.5 D (from 2 m to 67 cm viewing distance, P<0.05. There was no statistically significant difference in the near vision subscale scores of the 39-question National Eye Institute Visual Function Questionnaire or the overall scores of the Quality of Vision questionnaire, though significantly more trifocal subjects reported that the observed visual disturbances were “bothersome” (P<0.05.Conclusion: Both lens modalities provided subjects with excellent binocular near and distance vision, with similar low rates of visual disturbances and good reported functional vision. The trifocal IOL provided significantly better intermediate VA in the viewing distance range of 2 m to 67 cm, corresponding to viewing things such as a car dashboard or grocery shelf. VA was similar between groups at

  16. Scleral fixation of a single-piece multifocal intraocular lens.

    Science.gov (United States)

    Can, Ertugrul; Basaran, M Resat; Gül, Adem

    2013-01-01

    We describe an ab interno technique for injector implantation of a one-piece multifocal intraocular lens (IOL). Transscleral fixation of multifocal posterior chamber IOL implantation using an injector with ab interno technique was performed in an eye of a 9-year-old girl who had undergone pars plana lensectomy 2 years before for bilateral lens subluxation with unknown etiology. No major complications were encountered during a 3-month follow-up of the patient and excellent centration was observed during the follow-up period. Her preoperative best spectacle-corrected distance visual acuity of 20/32 improved to uncorrected distance visual acuity of 20/25. Closed-loop design of IOL served the function of eyelets and position of the IOL was provided using only a 2-point fixation. Intraoperative position adjustment of the IOL provided an excellent centralization of multifocal IOL.

  17. Bilateral Acanthamoeba ulcer in a user of disposable soft contact lenses: a tragic incident or a consequence of the aggressive policy of soft contact lens trading?

    Science.gov (United States)

    Sousa, Sidney Júlio de Faria E; Dias, Vanderson Glerian; Marcomini, Luís Antonio Gorla

    2008-01-01

    This is the report of a case of bilateral Acanthamoeba keratitis in a 19-year-old woman who bought a pair of disposable soft contact lenses in a boutique. She wore this same pair of lenses for 3 months daily without the appropriate care. This led to bilateral corneal transplantation with cataract extraction and also trabeculectomy in the right eye. When last seen, both grafts were crystal clear but the visual acuities were far from satisfactory. She also had bilateral secondary glaucoma, barely controlled by topical medication. Actually, the physical features and the wearing time characteristics of the disposable soft contact lenses created unprecedented difficulties to the medical surveillance of their wearers. Without the right assistance they tend to become careless regarding routine cleaning. They also feel free to buy less expensive lenses, to use saline instead of lens solutions, to violate the limits of wearing time and to extend the use over the sleeping period. Additionally, the aggressive marketing and the wide distribution of these lenses increase the chances that economically or educationally unprepared people will acquire them. The question that remains is: Is the present case an accidental event or an example of what is likely to happen in the future if the indiscriminate selling of disposable soft contact lenses continues to evolve?

  18. Visual outcome and changes in corneal endothelial cell density following aphakic iris-fixated intraocular lens implantation in pediatric eyes with subluxated lenses.

    Science.gov (United States)

    Siddiqui, Sorath Noorani; Khan, Ayesha

    2013-01-01

    To evaluate the visual outcome and corneal endothelial cell density after Artisan aphakic intraocular lens (IOL) implantation (Ophtec, Groningen, the Netherlands) in pediatric eyes with subluxated lenses. Artisan aphakic IOLs were implanted in 18 eyes of 11 children with subluxated lenses. Idiopathic subluxations and ectopia lentis due to Marfan syndrome were included, whereas subluxations due to trauma or buphthalmos were excluded. Best-corrected visual acuity (BCVA) and endothelial cell density were monitored. Mean postoperative BCVA and endothelial cell density at last follow-up visit were calculated. The age of children at the time of Artisan aphakic IOL implantation ranged from 8 to 16 years (mean: 11.58 ± 2.9 years). Mean follow-up was 9.12 ± 4.30 months. Mean postoperative logarithm of the minimum angle of resolution BCVA was 0.26 ± 0.13 (P = .001) and mean postoperative endothelial cell density was 2,860 ± 435 cells/mm(2) (P = .000). Mean endothelial cell loss was 17.1%. Artisan aphakic IOL implantation is a safe surgical choice in the management of ectopia lentis in the pediatric age group. It has minimal complications and is less traumatic to pediatric eyes. However, long-term follow-up of these children is required.[J Pediatr Ophthalmol Strabismus 2013;50(3):178-182.]. Copyright 2013, SLACK Incorporated.

  19. Visual outcome with the Oculentis Mplus intraocular lens

    Directory of Open Access Journals (Sweden)

    Si-Yuan Liu

    2017-11-01

    Full Text Available AIM: To evaluate the visual outcome of Oculentis Mplus intraocular lens(IOL.METHODS: Totally 20 eyes in 20 patients received phacoemulsification and Oculentis Mplus intraocular lens implantation were as test group, and 20 eyes(Aspira-aA IOLwere as control group. The following postoperative examinations were performed after operation for 3mo: uncorrected visual acuity of distance and near, refractive results, UBM examination, the rate of wearing spectacles and the complications. RESULTS: At 3mo after surgery, distance visual acuity of test group with Oculentis Mplus IOL were 0.10±0.03,the difference with control group was not significant(t=1.74, P>0.05. Eyes in test group had an uncorrected near acuity 0.11±0.04, the difference with control group was significant(t=15.53, PCONCLUSION: The implantation of Oculentis Mplus IOL not only has a good distance uncorrected visual acuity, but also with better near visual acuity. The surgery is safe, reliable and no special complication induced.

  20. Pseudomonas aeruginosa Infectious Keratitis in a High Oxygen Transmissible Rigid Contact Lens Rabbit Model

    Science.gov (United States)

    Wei, Cynthia; Zhu, Meifang; Petroll, W. Matthew; Robertson, Danielle M.

    2014-01-01

    Purpose. To establish a rabbit model of infectious Pseudomonas aeruginosa keratitis using ultrahigh oxygen transmissible rigid lenses and characterize the frequency and severity of infection when compared to a non–oxygen transmissible lens material. Methods. Rabbits were fit with rigid lenses composed of ultrahigh and non–oxygen transmissible materials. Prior to wear, lenses were inoculated with an invasive corneal isolate of P. aeruginosa stably conjugated to green fluorescent protein (GFP). Corneas were examined before and after lens wear using a modified Heidelberg Rostock Tomograph in vivo confocal microscope. Viable bacteria adherent to unworn and worn lenses were assessed by standard plate counts. The presence of P. aeruginosa-GFP and myeloperoxidase-labeled neutrophils in infected corneal tissue was evaluated using laser scanning confocal microscopy. Results. The frequency and severity of infectious keratitis was significantly greater with inoculated ultrahigh oxygen transmissible lenses. Infection severity was associated with increasing neutrophil infiltration and in severe cases, corneal melting. In vivo confocal microscopic analysis of control corneas following lens wear confirmed that hypoxic lens wear was associated with mechanical surface damage, whereas no ocular surface damage was evident in the high-oxygen lens group. Conclusions. These data indicate that in the absence of adequate tear clearance, the presence of P. aeruginosa trapped under the lens overrides the protective effects of oxygen on surface epithelial cells. These findings also suggest that alternative pathophysiological mechanisms exist whereby changes under the lens in the absence of frank hypoxic damage result in P. aeruginosa infection in the otherwise healthy corneal epithelium. PMID:25125601