WorldWideScience

Sample records for conformal treatment technique

  1. Quality assurance of a conformal treatment technique

    Energy Technology Data Exchange (ETDEWEB)

    Kroes, A P.G.; Bruinvis, I A.D.; Lanson, J H; Uiterwaal, G J [Nederlands Kanker Inst. ` Antoni van Leeuwenhoekhuis` , Amsterdam (Netherlands)

    1995-12-01

    For a parotid gland irradiation technique with a pair of oblique wedged photon beams the target coverage near the surface was investigated. The planning target volume extends to 5 millimetres under the skin; a minimum target dose of 95% is required when the dose at the centre is set to 100%. The treatment technique was simulated on a water phantom with a beam of 45 degree gantry angle, 55 degree wedge, 8 x 10 cm{sup 2} field size and the isocentre at 2 cm depth. Beam energies of 4, 6 and 8 MV were used. The dose distributions were measured in two orthogonal planes through the isocentre perpendicular to the water surface with p-type silicon diodes along lines through the isocentre every 45 degrees. Dose distributions were calculated in these planes with our 3-D planning system (U-Mplan, University of Michigan planning system), with model parameters are fitted to depth dose curves and profiles of open and wedged normally incident beams. The location of the 95% isodose was determined in five points near the surface. For 4, 6 and 8 MV the depths of the 95% isodose were 6.0, 10.3 and 11.0 mm, respectively. The depths of the 95% points of single normally incident open fields were 6.0, 9.0 and 11.5 mm, respectively. The treatment planning system (TPS) calculated the 95% isodose for the parotid technique at 5.5, 7.3 and 11.5 mm depths, for 4, 6 and 8 MV, respectively. Thus for 6 MV the 95% was 3 mm deeper than calculated by the TPS; 2 mm were caused by the inaccuracy of the open field depth dose curve fit in the build-up region. The depth near the surface of the 95% isodose for this treatment technique can be estimated from single open field depth dose curves with acceptable accuracy. This result is not obvious because the effects of the wedge and oblique incidence on the dose distribution are also involved. The TPS performed well for the 4 and 8 MV beams, but for treatments with 6 MV target under dosage could have remained undetected. (Abstract Truncated)

  2. Three-dimensional conformal pancreas treatment: comparison of four- to six-field techniques

    International Nuclear Information System (INIS)

    Higgins, Patrick D.; Sohn, Jason W.; Fine, Robert M.; Schell, Michael C.

    1995-01-01

    Purpose: We compare practical conformal treatment approaches to pancreatic cancer using 6 and 18 MV photons and contrast those approaches against standard techniques. Methods and Materials: A four-field conformal technique for treating pancreas cancer has been developed using nonopposed 18 MV photons. This approach has been extended to 6 MV photon application by the addition of one to two fields. These techniques have been optimized to increase sparing of normal liver and bowel, compared with opposed-field methods, to improve patient tolerance of high doses. In this study we compare these techniques in a simulated tumor model in a cylindrical phantom. Dose-volume analysis is used to quantify differences between the conformal, nonopposed techniques with conformal, opposed field methods. This model is also used to evaluate the effect of 1-2 cm setup errors on dose-volume coverage. Results: Dose-volume analysis demonstrates that five-to-six field conformal treatments using 6 MV photons provides similar or better dose coverage and normal tissue sparing characteristics as an optimized 18 MV, four-field approach when 1-2 cm margins are included for setup uncertainty. All approaches using nonopposed beam geometry provide significant reduction in the volume of tissue encompassed by the 30-50% isodose surfaces, as compared with four-field box techniques. Conclusions: Three-dimensional (3D) conformal treatments can be designed that significantly improve dose-volume characteristics over conventional treatment designs without costing unacceptable amounts of machine time. Further, deep intraabdominal sites can be adequately accessed and treated on intermediate energy machines with a relatively moderate increase in machine time

  3. Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer

    International Nuclear Information System (INIS)

    Herrassi, Mohamed Yassine; Bentayeb, Farida; Malisan, Maria Rosa

    2013-01-01

    For the head-and-neck cancer bilateral irradiation, intensity-modulated radiation therapy (IMRT) is the most reported technique as it enables both target dose coverage and organ-at-risk (OAR) sparing. However, during the last 20 years, three-dimensional conformal radiotherapy (3DCRT) techniques have been introduced, which are tailored to improve the classic shrinking field technique, as regards both planning target volume (PTV) dose conformality and sparing of OARs, such as parotid glands and spinal cord. In this study, we tested experimentally in a sample of 13 patients, four of these advanced 3DCRT techniques, all using photon beams only and a unique isocentre, namely Bellinzona, Forward-Planned Multisegments (FPMS), ConPas, and field-in-field (FIF) techniques. Statistical analysis of the main dosimetric parameters of PTV and OARs DVHs as well as of homogeneity and conformity indexes was carried out in order to compare the performance of each technique. The results show that the PTV dose coverage is adequate for all the techniques, with the FPMS techniques providing the highest value for D95%; on the other hand, the best sparing of parotid glands is achieved using the FIF and ConPas techniques, with a mean dose of 26 Gy to parotid glands for a PTV prescription dose of 54 Gy. After taking into account both PTV coverage and parotid sparing, the best global performance was achieved by the FIF technique with results comparable to that of IMRT plans. This technique can be proposed as a valid alternative when IMRT equipment is not available or patient is not suitable for IMRT treatment. (author)

  4. Treatment planning evaluation of non-coplanar techniques for conformal radiotherapy of the prostate

    International Nuclear Information System (INIS)

    Bedford, James L.; Henrys, Anthony J.; Dearnaley, David P.; Khoo, Vincent S.

    2005-01-01

    Background and purpose: To evaluate the benefit of using non-coplanar treatment plans for irradiation of two different clinical treatment volumes: prostate only (PO) and the prostate plus seminal vesicles (PSV). Material and methods: An inverse planning algorithm was used to produce three-field, four-field, five-field and six-field non-coplanar treatment plans without intensity-modulation in ten patients. These were compared against a three-field coplanar plan. A dose of 74 Gy was prescribed to the isocentre. Plans were compared using the minimum dose to the planning target volume (PTV), maximum dose to the small bowel, and irradiated volumes of rectum, bladder and femoral head. Biological indices were also evaluated. Results: For the PO group, volume of rectum irradiated to 60 Gy (V 60 ) was 22.5±3.7% for the coplanar plan, and 21.5±5.3% for the five-field non-coplanar plan, which was the most beneficial (p=0.3). For the PSV group, the five-field non-coplanar plan was again the most beneficial. Rectal V 60 was in this case reduced from 41.5±10.4% for the coplanar plan to 35.2±9.3% for the non-coplanar plan (p=0.02). Conclusions: The use of non-coplanar beams in conformal prostate radiotherapy provides a small increase in rectal sparing, more significantly with PSV volumes than for PO volumes

  5. 'Boomerang' technique: an improved method for conformal treatment of locally advanced nasopharyngeal cancer

    International Nuclear Information System (INIS)

    Corry, June; D'Costa, Leta; Porceddu, Sandro; Peters, Lester J.; Hornby, Colin; Fisher, Richard; Rischin, Danny

    2004-01-01

    The primary aim of the present study was to assess radiation dosimetry and subsequent clinical outcomes in patient: with locally advanced nasopharyngeal cancer using a novel radiation technique termed the 'Boomerang'. Dosimetric comparisons were made with both conventional and intensity modulated radiation therapy (IMRT) techniques. Thi; is a study of 22 patients treated with this technique from June 1995 to October 1998. The technique used entailec delivery of 36 Gy in 18 fractions via parallel opposed fields, then 24 Gy in 12 fractions via asymmetric rotating arc field' for a total of 60 Gy in 30 fractions. Patients also received induction and concurrent chemotherapy. The radiation dosimetry was excellent. Dose-volume histograms showed that with the arc fields, 90% of the planning target volume received 94% of the prescribed dose. Relative to other conventional radiation therapy off-cord techniques, the Boomerang technique results in a 27% greater proportion of the prescribed dose being received by 90% of the planning target volume. This translates into an overall 10% greater dose received for the same prescribed dose. At 3 years, the actuarial loco-regional control rate, the failure-free survival rate and the overall survival rate were 91, 75 and 91%, respectively. At 5 years, the actuarial loco-regional control rate, the failure-free survival rate and the overall survival rate were 74, 62 and 71%, respectively. The Boomerang technique provided excellent radiation dosimetry with correspondingly good loco-regional control rates (in conjunction with chemotherapy) and very acceptable acute and late toxicity profiles. Because treatment can be delivered with conventional standard treatment planning and delivery systems, it is a validated treatment option for centres that do not have the capability or capacity for IMRT. A derivative of the Boomerang technique, excluding the parallel opposed component, is now our standard for patients with locally advanced

  6. 'Boomerang' technique: an improved method for conformal treatment of locally advanced nasopharyngeal cancer.

    Science.gov (United States)

    Corry, June; Hornby, Colin; Fisher, Richard; D'Costa, Ieta; Porceddu, Sandro; Rischin, Danny; Peters, Lester J

    2004-06-01

    The primary aim of the present study was to assess radiation dosimetry and subsequent clinical outcomes in patients with locally advanced nasopharyngeal cancer using a novel radiation technique termed the 'Boomerang'. Dosimetric comparisons were made with both conventional and intensity modulated radiation therapy (IMRT) techniques. This is a study of 22 patients treated with this technique from June 1995 to October 1998. The technique used entailed delivery of 36 Gy in 18 fractions via parallel opposed fields, then 24 Gy in 12 fractions via asymmetric rotating arc fields for a total of 60 Gy in 30 fractions. Patients also received induction and concurrent chemotherapy. The radiation dosimetry was excellent. Dose-volume histograms showed that with the arc fields, 90% of the planning target volume received 94% of the prescribed dose. Relative to other conventional radiation therapy off-cord techniques, the Boomerang technique results in a 27% greater proportion of the prescribed dose being received by 90% of the planning target volume. This translates into an overall 10% greater dose received for the same prescribed dose. At 3 years, the actuarial loco-regional control rate, the failure-free survival rate and the overall survival rate were 91, 75 and 91%, respectively. At 5 years, the actuarial loco-regional control rate, the failure-free survival rate and the overall survival rate were 74, 62 and 71%, respectively. The Boomerang technique provided excellent radiation dosimetry with correspondingly good loco-regional control rates (in conjunction with chemotherapy) and very acceptable acute and late toxicity profiles. Because treatment can be delivered with conventional standard treatment planning and delivery systems, it is a validated treatment option for centres that do not have the capability or capacity for IMRT. A derivative of the Boomerang technique, excluding the parallel opposed component, is now our standard for patients with locally advanced

  7. A treatment planning comparison of two different 3D conformal techniques for irradiation of head and neck cancer patients

    International Nuclear Information System (INIS)

    Krstevska, Valentina; Lukarski, Dusko; Petkovska, Sonja

    2010-01-01

    The purpose of this treatment planning study was to compare two different three dimensional conformal irradiation techniques for head and neck cancer patients. For 33 patients with head and neck carcinoma, irradiated according to the classical technique, we computed and evaluated a second irradiation technique in order to optimize the treatment planning protocol. The classical technique, termed 'electron-photon fields', employed two lateral semi-fields (23 fractions) for irradiation of the upper part of the planning target volume that should receive 50 Gy (PTV50) and an anterior and posterior field for the lower part. After the 23rd fraction the lateral fields were reduced from the dorsal side (2 fractions), in order to exclude the spinal cord from them. At the same time the dose to the shielded part of the target volume was delivered with matched electron fields. Finally, after the 25th fraction, the high risk volume was irradiated to the desired dose with plan where the spinal cord was completely shielded. In the new technique, termed 'oblique photon fields', 4 oblique isocentric photon fields were used (25 fractions): two anterior fields that covered the entire target volume that should receive 50 Gy and two posterior fields that covered only half of the target volume in order to shield the spinal cord. Thus, the necessity for using electron fields is eliminated. We kept the plan for irradiation of the high risk planning target volume the same as in the classical technique. The prescribed dose per fraction in all plans was 2 Gy. In both techniques the plans were optimized to the same maximal point dose and the same dose to the spinal cord. The oblique fields plan showed better coverage and homogeneity of the PTV50, except for the patients with positive resection margins receiving postoperative radiotherapy (receiving 66 Gy), where the coverage did not differ significantly. The conformity in both techniques did not differ significantly. The mean dose to the

  8. 94: Treatment plan optimization for conformal therapy

    International Nuclear Information System (INIS)

    Rosen, I.I.; Lane, R.G.

    1987-01-01

    Computer-controlled conformal radiation therapy techniques can deliver complex treatments utilizing large numbers of beams, gantry angles and beam shapes. Linear programming is well-suited for planning conformal treatments. Given a list of available treatment beams, linear programming calculates the relative weights of the beams such that the objective function is optimized and doses to constraint points are within the prescribed limits. 5 refs.; 3 figs

  9. Treatment planning with protons for pediatric retinoblastoma, medulloblastoma, and pelvic sarcoma: How do protons compare with other conformal techniques?

    International Nuclear Information System (INIS)

    Lee, Catherine T.; Bilton, Stephen D.; Famiglietti, Robin M.; Riley, Beverly A.; Mahajan, Anita; Chang, Eric L.; Maor, Moshe H.; Woo, Shiao Y.; Cox, James D.; Smith, Alfred R.

    2005-01-01

    Purpose: To calculate treatment plans and compare the dose distributions and dose-volume histograms (DVHs) for photon three-dimensional conformal radiation therapy (3D-CRT), electron therapy, intensity-modulated radiation therapy (IMRT), and standard (nonintensity modulated) proton therapy in three pediatric disease sites. Methods and Materials: The tumor volumes from 8 patients (3 retinoblastomas, 2 medulloblastomas, and 3 pelvic sarcomas) were studied retrospectively to compare DVHs from proton therapy with 3D-CRT, electron therapy, and IMRT. In retinoblastoma, several planning techniques were analyzed: A single electron appositional beam was compared with a single 3D-CRT lateral beam, a 3D-CRT anterior beam paired with a lateral beam, IMRT, and protons. In medulloblastoma, three posterior fossa irradiation techniques were analyzed: 3D-CRT, IMRT, and protons. Craniospinal irradiation (which consisted of composite plans of both the posterior fossa and craniospinal components) was also evaluated, primarily comparing spinal irradiation using 3D-CRT electrons, 3D-CRT photons, and protons. Lastly, in pelvic sarcoma, 3D-CRT, IMRT, and proton plans were assessed. Results: In retinoblastoma, protons resulted in the best target coverage combined with the most orbital bone sparing (10% was the mean orbital bone volume irradiated at ≥5 Gy for protons vs. 25% for 3D-CRT electrons, 69% for IMRT, 41% for a single 3D lateral beam, 51% for a 3D anterolateral beam with a lens block, and 65% for a 3D anterolateral beam without a lens block). A single appositional electron field was the next best technique followed by other planning approaches. In medulloblastoma, for posterior fossa and craniospinal irradiation, protons resulted in the least dose to the cochlea (for only posterior fossa irradiation at ≥20 Gy, 34% was the mean cochlear volume irradiated for protons, 87% for IMRT, 89% for 3D-CRT) and hypothalamus-pituitary axis (for only posterior fossa irradiation at ≥10 Gy

  10. The intercomparison of the dose distributions between conformation techniques with pions and photons

    International Nuclear Information System (INIS)

    Karasawa, K.; Nakagawa, K.; Akanuma, A.

    1990-01-01

    To compare conformation radiation treatment with pions vs photons, dose volume histograms (DVH) to the critical organs, including the spinal cord, kidney, and intestine, were examined in a patient with retroperitoneal soft tissue sarcoma. For photon conformation treatment, the following techniques were used: 360 degree rotation conformation technique (photon conformation), 4 fixed field technique (photon 4-field), and 2-axis conformation technique (photon 2-axial conformation). According to the DVH reduction method, complication probability was estimated. The concave portion of the target was conformed by pion conformation treatment, but not by photon conformation treatment. Pion conformation for the intestine showed the best DVH, whereas photon 4-field technique showed the worst DVH. For the kidney, pion conformation showed better DVH as compared with any other photon conformation treatment technique. In the spinal cord, photon 2-axial conformation was far superior, followed by pion conformation and then photon conformation and 4-field technique. A 2-axial technique showed a bigger inhomogeneity inside the target volume which is critical in curative treatment. TD 50 was 72 Gy for pion conformation, 53 Gy for photon conformation, 51 Gy for photon 4-field, and 68 Gy for photon 2-axial conformation. Complication probabilities for these conformation techniques at 60 Gy were 3%, 85%, 97%, and 9%. In view of tumor control probabilities, pion seems to have the biggest therapeutic ratio among these techniques. (N.K.)

  11. Comparison of conformal and intensity modulated radiation therapy techniques for treatment of pelvic tumors. Analysis of acute toxicity

    International Nuclear Information System (INIS)

    Ferrigno, Robson; Santos, Adriana; Martins, Lidiane C; Weltman, Eduardo; Chen, Michael J; Sakuraba, Roberto; Lopes, Cleverson P; Cruz, José C

    2010-01-01

    This retrospective analysis reports on the comparative outcome of acute gastrointestinal (GI) and genitourinary (GU) toxicities between conformal radiation therapy (CRT) and intensity modulated radiation therapy (IMRT) techniques in the treatment of patients with pelvic tumors. From January 2002 to December 2008, 69 patients with pelvic tumors underwent whole pelvic CRT and 65 underwent whole pelvic IMRT to treat pelvic lymph nodes and primary tumor regions. Total dose to the whole pelvis ranged from 50 to 50.4 Gy in 25 to 28 daily fractions. Chemotherapy (CT) regimen, when employed, was based upon primary tumor. Acute GI and GU toxicities were graded by RTOG/EORTC acute radiation morbidity criteria. Absence of GI symptoms during radiotherapy (grade 0) was more frequently observed in the IMRT group (43.1% versus 8.7; p < 0.001) and medication for diarrhea (Grade 2) was more frequently used in the CRT group (65.2% versus 38.5%; p = 0.002). Acute GI grade 1 and 3 side effects incidence was similar in both groups (18.5% versus 18.8%; p = 0.95 and 0% versus 7.2%; p = 0.058, respectively). Incidence of GU toxicity was similar in both groups (grade 0: 61.5% versus 66.6%, p = 0.54; grade 1: 20% versus 8.7%, p = 0.06; grade 2: 18.5% versus 23.5%, p = 0.50 and grade 3: 0% versus 1.5%, p > 0.99). This comparative case series shows less grade 2 acute GI toxicity in patients treated with whole pelvic IMRT in comparison with those treated with CRT. Incidence of acute GU toxicity was similar in both groups

  12. The comparison of 5-field conformal radiotherapy techniques for the treatment of prostate cancer: The best for femoral head sparing

    International Nuclear Information System (INIS)

    Zare, Mahkameh; Lashkari, Marzieh; Ghalehtaki, Reza; Ghasemi, Arash; Dehghan Manshadi, Hamidreza; Mir, Ali; Noorollahi, Somayeh; Alamolhoda, Mahboobeh

    2016-01-01

    External radiotherapy is a standard treatment procedure for localized prostate cancer. Given the relatively high long term survival treatment complications have been brought in center of attention. In this planning study, between 2012 and 2014, CT simulation data of 90 consecutive high-risk prostate cancer patients were collected. In the first phase, all were planned for whole pelvis irradiation up to 46Gy in 23 daily fractions. In the second phase, only the prostate gland was the target of radiation. Next, the subjects were divided randomly into three groups and each received a unique 5field conformal radiation plan including Plan A (Gantry angle: 0, 60, 120, 240, and 300), Plan B (Gantry angles: 0, 90, 120, 240, and 270) and Plan C (Gantry angles: 0, 60, 90, 270, and 300). The total dose was 70Gy. For each patient, the rectum, bladder, and both femoral heads were contoured as the at risk organs (OAR). From dose volume histograms, the proportional dose of PTV V100, the bladder and rectum V80 and V90 and femoral head V50 and V100 were calculated in all subjects and compared across plans. A statistically significant difference in the femoral head V50 and V100 was found between our studied 5field plans so that in Plan A (beam angles: 0, 60, 120, 240 and 300) less dose was received by both heads of femur. This study suggests that 5 field treatment planning including an anterior, two anterior oblique and two posterior oblique portals to be more proper for 3D conformal radiotherapy in order to spare femoral head with acceptable PTV coverage, and bladder and rectal doses.

  13. Dosimetric Verification and Evaluation of the 3-D Conformal Parotid Gland-Sparing Irradiation Technique for Bilateral Neck Treatment at University Hospital Centre Zagreb

    International Nuclear Information System (INIS)

    Kovacevic, N; Hrsak, H.; Bibic, J.

    2011-01-01

    3-D Conformal Parotid Gland-Sparing Irradiation Technique for Bilateral Neck (ConPas) is an alternative to Intensity-modulated radiotherapy (IMRT), and is in routine use at University Hospital Centre Rebro (KBC-Rebro), Zagreb. This technique includes highly asymmetric wedged conformal multi-leaf fields and demands very precise application. The aim of this paper is to present the dosimetric verification method of ConPas (and evaluation of ConPas applicability) as performed at KBC, taking into account the precision of the Treatment Planning System (TPS), possibilities of linear accelerator and patient set-up error. Results for two patients are shown in some details.ConPas is a rather sophisticated method and demands high precision in the whole radiotherapy process. Verification of ConPas using IMRT Verification Matrix Phantom shows good agreement between measured and predicted doses inside and outside PTV regions of the head and neck. Furthermore, a careful track of the positioning during the treatment shows that the overall set-up error is very small (practically negligible). When possible, one parotid gland may be partially spared, and therefore its function preserved at least to some extent. (author)

  14. Three-dimensional treatment planning for postoperative radiotherapy in patients with node-positive cervical cancer. Comparison between a conventional and a conformal technique

    Energy Technology Data Exchange (ETDEWEB)

    Olofsen-van Acht, M.J.J.; Quint, S.; Seven, M.; Berg, H.A. van den; Levendag, P.C. [University Hospital Rotterdam (Netherlands). Dept. of Radiation Oncology; Santvoort, J.P.C. van [University Hospital Rotterdam (Netherlands). Subdivision of Clinical Physics; Logmans, A. [University Hospital Rotterdam (Netherlands). Dept. of Gynecologic Oncology

    1999-09-01

    Purpose: Reduction of irradiated small bowel volume, using a conformal three-dimensional treatment planning technique in postoperative radiotherapy of cervical cancer patients. Patients and Methods: Large gynecological treatment fields including the para-aortic nodes were analyzed in 15 patients. A conventional treatment plan with anterior and posterior (AP-PA) parallel opposed fields and a 3D 4-field conformal radiotherapy plan with a central blocking of small bowel were compared for each patient. Dose-volume histograms and dose parameters were established. Because of the tolerance constraints of the small bowel, the cumulative dose applied to the target was 48.6 Gy. Results: The mean Tumor Control Probability (TCP) values for both the conventional and the conformal technique were 0.60 and 0.61, respectively, with ranges of 0.56 to 0.67 and 0.57 to 0.66, respectively. The mean volume receiving 95% or more of the prescribed dose (V95) of the small bowel was 47.6% (32.5 to 66.3%) in the AP-PA technique and 14.9% (7.0 to 22.5%) in the conformal technique (p<0.001), indicating a significant reduction in irradiated volume of small bowel in the higher dose range. The mean Normal Tissue Complication Probability (NTCP) decreased from 0.11 to 0.03 with the conformal plan. In patients who received a pedicled omentoplasty during surgery, the mean V95 for small bowel could be reduced to 8.5% (7.0 to 9.9%). The mean median dose to the kidneys was only slightly elevated in the conformal treatment. Especially the mean dose to the right kidney in conventional vs conformal treatment was 3.3 vs 7.9 Gy. The mean near-minimum dose (D95) to the rectosigmoid decreased from 48.4 to 30.1 Gy in the conformal plan compared to the conventional plan. Conclusion: The small bowel dose can be significantly reduced with 3D treatment planning, particularly if a predicled omentoplasty is performed. This allows dose escalation to the tumor region without unacceptable toxicity for the small bowel

  15. The superiority of hybrid-volumetric arc therapy (VMAT) technique over double arcs VMAT and 3D-conformal technique in the treatment of locally advanced non-small cell lung cancer – A planning study

    International Nuclear Information System (INIS)

    Chan, Oscar S.H.; Lee, Michael C.H.; Hung, Albert W.M.; Chang, Amy T.Y.; Yeung, Rebecca M.W.; Lee, Anne W.M.

    2011-01-01

    Purpose: To compare the dosimetric performance of three different treatment techniquesconformal radiotherapy (CRT), double arcs volumetric modulated arc therapy (RapidArc, RA) and Hybrid-RapidArc (H-RA) for locally-advanced non-small cell lung cancer (NSCLC). Material and methods: CRT, RA and H-RA plans were optimized for 24 stage III NSCLC patients. The target prescription dose was 60 Gy. CRT consisted of 5–7 coplanar fields, while RA comprised of two 204 o arcs. H-RA referred to two 204 o arcs plus 2 static fields, which accounted for approximately half of the total dose. The plans were optimized to fulfill the departmental plan acceptance criteria. Results: RA and H-RA yielded a 20% better conformity compared with CRT. Lung volume receiving >20 Gy (V20) and mean lung dose (MLD) were the lowest in H-RA (V20 1.7% and 2.1% lower, MLD 0.59 Gy and 0.41 Gy lower than CRT and RA respectively) without jeopardizing the low-dose lung volume (V5). H-RA plans gave the lowest mean maximum spinal cord dose (34.4 Gy, 3.9 Gy < CRT and 2.2 Gy < RA plans) and NTCP of lung. Higher average MU per fraction (addition 52.4 MU) was observed with a reduced treatment time compared with CRT plans. Conclusion: The H-RA technique was superior in dosimetric outcomes for treating locally-advanced NSCLC compared to CRT and RA.

  16. 3-D conformal radiation therapy - Part I: Treatment planning

    International Nuclear Information System (INIS)

    Burman, Chandra M.; Mageras, Gikas S.

    1997-01-01

    Objective: In this presentation we will look into the basic components of 3-dimensional conformal treatment planning, and will discuss planning for some selected sites. We will also review some current and future trends in 3-D treatment planning. External beam radiation therapy is one of the arms of cancer treatment. In the recent years 3-D conformal therapy had significant impact on the practice of external beam radiation therapy. Conformal radiation therapy shapes the high-dose volume so as to conform to the target volume while minimizing the dose to the surrounding normal tissues. The advances that have been achieved in conformal therapy are in part due to the development of 3-D treatment planning, which in turn has capitalized on 3-D imaging for tumor and normal tissue localization, as well as on available computational power for the calculation of 3-D dose distributions, visualization of anatomical and dose volumes, and numerical evaluation of treatment plans. In this course we will give an overview of how 3-D conformal treatments are designed and transferred to the patient. Topics will include: 1) description of the major components of a 3-D treatment planning system, 2) techniques for designing treatments, 3) evaluation of treatment plans using dose distribution displays, dose-volume histograms and normal tissue complication probabilities, 4) implementation of treatments using shaped blocks and multileaf collimators, 5) verification of treatment delivery using portal films and electronic portal imaging devices. We will also discuss some current and future trends in 3-D treatment planning, such as field shaping with multileaf collimation, computerized treatment plan optimization, including the use of nonuniform beam profiles (intensity modulation), and incorporating treatment uncertainties due to patient positioning errors and organ motion into treatment planning process

  17. Conformal techniques for OPE in asymptotically free quantum field theory

    International Nuclear Information System (INIS)

    Craigie, N.S.; Dobrev, V.K.

    1982-06-01

    We discuss the relationship between the short-distance behaviour of vertex functions and conformal invariance in asymptotically free theories. We show how conformal group techniques can be used to derive spectral representations of wave functions and vertex functions in QCD. (author)

  18. NMR and modelling techniques in structural and conformation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, R J [Liverpool Univ. (United Kingdom)

    1994-12-31

    The use of Lanthanide Induced Shifts (L.I.S.) and modelling techniques in conformational analysis is presented. The use of Co{sup III} porphyrins as shift reagents is discussed, with examples of their use in the conformational analysis of some heterocyclic amines. (author) 13 refs., 9 figs.

  19. 3-D conformal radiation therapy - Part II: Computer-controlled 3-D treatment delivery

    International Nuclear Information System (INIS)

    Benedick, A.

    1997-01-01

    Purpose/Objective: This course will describe the use of computer-controlled treatment delivery techniques for treatment of patients with sophisticated conformal therapy. In particular, research and implementation issues related to clinical use of computer-controlled conformal radiation therapy (CCRT) techniques will be discussed. The possible/potential advantages of CCRT techniques will be highlighted using results from clinical 3-D planning studies. Materials and Methods: In recent years, 3-D treatment planning has been used to develop and implement 3-D conformal therapy treatment techniques, and studies based on these conformal treatments have begun to show the promise of conformal therapy. This work has been followed by the development of commercially-available multileaf collimator and computer control systems for treatment machines. Using these (and other) CCRT devices, various centers are beginning to clinically use complex computer-controlled treatments. Both research and clinical CCRT treatment techniques will be discussed in this presentation. General concepts and requirements for CCRT will be mentioned. Developmental and clinical experience with CCRT techniques from a number of centers will be utilized. Results: Treatment planning, treatment preparation and treatment delivery must be approached in an integrated fashion in order to clinically implement CCRT treatment techniques, and the entire process will be discussed. Various CCRT treatment methodologies will be reviewed from operational, dosimetric, and technical points of view. The discussion will concentrate on CCRT techniques which are likely to see rather wide dissemination over the next several years, including particularly the use of multileaf collimators (MLC), dynamic and segmental conformal therapy, conformal field shaping, and other related techniques. More advanced CCRT techniques, such as the use of individualized intensity modulation of beams or segments, and the use of computer

  20. Selection of candidate wells and optimization of conformance treatment design in the Barrancas Field using a 3D conformance simulator

    Energy Technology Data Exchange (ETDEWEB)

    Crosta, Dante; Elitseche, Luis [Repsol YPF (Argentina); Gutierrez, Mauricio; Ansah, Joe; Everett, Don [Halliburton Argentina S.A., Buenos Aires (Argentina)

    2004-07-01

    Minimizing the amount of unwanted water production is an important goal at the Barrancas field. This paper describes a selection process for candidate injection wells that is part of a pilot conformance project aimed at improving vertical injection profiles, reducing water cut in producing wells, and improving ultimate oil recovery from this field. The well selection process is based on a review of limited reservoir information available for this field to determine inter-well communications. The methodology focuses on the best use of available information, such as production and injection history, well intervention files, open hole logs and injectivity surveys. After the candidate wells were selected and potential water injection channels were identified, conformance treatment design and future performance of wells in the selected pilot area were evaluated using a new 3 -D conformance simulator, developed specifically for optimization of the design and placement of unwanted fluid shut-off treatments. Thus, when acceptable history match ing of the pilot area production was obtained, the 3 -D simulator was used to: evaluate the required volume of selected conformance treatment fluid; review expected pressures and rates during placement;. model temperature behavior; evaluate placement techniques, and forecast water cut reduction and incremental oil recovery from the producers in this simulated section of the pilot area. This paper outlines a methodology for selecting candidate wells for conformance treatments. The method involves application of several engineering tools, an integral component of which is a user-friendly conformance simulator. The use of the simulator has minimized data preparation time and allows the running of sensitivity cases quickly to explore different possible scenarios that best represent the reservoir. The proposed methodology provides an efficient means of identifying conformance problems and designing optimized solutions for these individual

  1. Conformal Radiotherapy: Physics, Treatment Planning and Verification. Proceedings book

    Energy Technology Data Exchange (ETDEWEB)

    De Wagter, C [ed.

    1995-12-01

    The goal of conformal radiotherapy is to establish radiation dose distributions that conform tightly to the target volume in view of limiting radiation to normal tissues. Conformal radiotherapy significantly improves both local control and palliation and thus contributes to increase survival and to improve the quality of life. The subjects covered by the symposium include : (1) conformal radiotherapy and multi-leaf collimation; (2) three dimensional imaging; (3) treatment simulation, planning and optimization; (4) quality assurance; and (5) dosimetry. The book of proceedings contains the abstracts of the invited lectures, papers and poster presentations as well as the full papers of these contributions.

  2. Conformal Radiotherapy: Physics, Treatment Planning and Verification. Proceedings book

    International Nuclear Information System (INIS)

    De Wagter, C.

    1995-12-01

    The goal of conformal radiotherapy is to establish radiation dose distributions that conform tightly to the target volume in view of limiting radiation to normal tissues. Conformal radiotherapy significantly improves both local control and palliation and thus contributes to increase survival and to improve the quality of life. The subjects covered by the symposium include : (1) conformal radiotherapy and multi-leaf collimation; (2) three dimensional imaging; (3) treatment simulation, planning and optimization; (4) quality assurance; and (5) dosimetry. The book of proceedings contains the abstracts of the invited lectures, papers and poster presentations as well as the full papers of these contributions

  3. Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Hamilton, Russell J.; Kuchnir, Franca T.; Sweeney, Patrick; Rubin, Steven J.; Dujovny, Manuel; Pelizzari, Charles A.; Chen, George T. Y.

    1995-01-01

    Purpose: Compare the use of static conformal fields with the use of multiple noncoplanar arcs for stereotactic radiosurgery or stereotactic radiotherapy treatment of intracranial lesions. Evaluate the efficacy of these treatment techniques to deliver dose distributions comparable to those considered acceptable in current radiotherapy practice. Methods and Materials: A previously treated radiosurgery case of a patient presenting with an irregularly shaped intracranial lesion was selected. Using a three-dimensional (3D) treatment-planning system, treatment plans using a single isocenter multiple noncoplanar arc technique and multiple noncoplanar conformal static fields were generated. Isodose distributions and dose volume histograms (DVHs) were computed for each treatment plan. We required that the 80% (of maximum dose) isodose surface enclose the target volume for all treatment plans. The prescription isodose was set equal to the minimum target isodose. The DVHs were analyzed to evaluate and compare the different treatment plans. Results: The dose distribution in the target volume becomes more uniform as the number of conformal fields increases. The volume of normal tissue receiving low doses (> 10% of prescription isodose) increases as the number of static fields increases. The single isocenter multiple arc plan treats the greatest volume of normal tissue to low doses, approximately 1.6 times more volume than that treated by four static fields. The volume of normal tissue receiving high (> 90% of prescription isodose) and intermediate (> 50% of prescription isodose) doses decreases by 29 and 22%, respectively, as the number of static fields is increased from four to eight. Increasing the number of static fields to 12 only further reduces the high and intermediate dose volumes by 10 and 6%, respectively. The volume receiving the prescription dose is more than 3.5 times larger than the target volume for all treatment plans. Conclusions: Use of a multiple noncoplanar

  4. Anaerobic treatment techniques

    International Nuclear Information System (INIS)

    Boehnke, B.; Bischofsberger, W.; Seyfried, C.F.

    1993-01-01

    This practical and theoretical guide presents the current state of knowledge in anaerobic treatment of industrial effluents with a high organic pollutant load and sewage sludges resulting from the treatment of municipal and industrial waste water. Starting from the microbiological bases of anaerobic degradation processes including a description and critical evaluation of executed plants, the book evolves the process-technical bases of anaerobic treatment techniques, derives relative applications, and discusses these with reference to excuted examples. (orig./UWA). 232 figs [de

  5. The sewing technique for strings and conformal field theories

    International Nuclear Information System (INIS)

    Di Vecchia, P.

    1989-01-01

    We discuss recent results obtained from the sewing procedure for strings and conformal field theories. They are summarized by the N Point [String] g loop Vertex V N;g , that is the 'generating functional' of all correlation functions [scattering amplitudes] of the theory on a genus g Riemann surface. We discuss V N;g for free bosonic theory with arbitrary background charge and for fermionic and bosonic bc systems. By saturating those vertices with highest weight states we obtain in a simple way the correlation functions of the corresponding primary fields on genus g Riemann surfaces that reproduce known results including the correlation functions of a bosonic bc system, that present a number of peculiarities. We construct also V N;g for the bosonic and fermionic string. In particular this technique allows one to explicitly construct the measure of integration over the moduli and to study the various pinching limits in order to check the finiteness of superstring theories. (orig.)

  6. Conformal techniques in string theory and string field theory

    International Nuclear Information System (INIS)

    Giddings, S.B.

    1987-01-01

    The application of some conformal and Riemann surface techniques to string theory and string field theory is described. First a brief review of Riemann surface techniques and of the Polyakov approach to string theory is presented. This is followed by a discussion of some features of string field theory and of its Feynman rules. Specifically, it is shown that the Feynman diagrams for Witten's string field theory respect modular invariance, and in particular give a triangulation of moduli space. The Polyakov formalism is then used to derive the Feynman rules that should follow from this theory upon gauge-fixing. It should also be possible to apply this derivation to deduce the Feynman rules for other gauge-fixed string field theories. Following this, Riemann surface techniques are turned to the problem of proving the equivalence of the Polyakov and light-cone formalisms. It is first shown that the light-cone diagrams triangulate moduli space. Then the Polyakov measure is worked out for these diagrams, and shown to equal that deduced from the light-cone gauge fixed formalism. Also presented is a short description of the comparison of physical states in the two formalisms. The equivalence of the two formalisms in particular constitutes a proof of the unitarity of the Polyakov framework for the closed bosonic string

  7. Conventional and conformal technique of external beam radiotherapy in locally advanced cervical cancer: Dose distribution, tumor response, and side effects

    Science.gov (United States)

    Mutrikah, N.; Winarno, H.; Amalia, T.; Djakaria, M.

    2017-08-01

    The objective of this study was to compare conventional and conformal techniques of external beam radiotherapy (EBRT) in terms of the dose distribution, tumor response, and side effects in the treatment of locally advanced cervical cancer patients. A retrospective cohort study was conducted on cervical cancer patients who underwent EBRT before brachytherapy in the Radiotherapy Department of Cipto Mangunkusumo Hospital. The prescribed dose distribution, tumor response, and acute side effects of EBRT using conventional and conformal techniques were investigated. In total, 51 patients who underwent EBRT using conventional techniques (25 cases using Cobalt-60 and 26 cases using a linear accelerator (LINAC)) and 29 patients who underwent EBRT using conformal techniques were included in the study. The distribution of the prescribed dose in the target had an impact on the patient’s final response to EBRT. The complete response rate of patients to conformal techniques was significantly greater (58%) than that of patients to conventional techniques (42%). No severe acute local side effects were seen in any of the patients (Radiation Therapy Oncology Group (RTOG) grades 3-4). The distribution of the dose and volume to the gastrointestinal tract affected the proportion of mild acute side effects (RTOG grades 1-2). The urinary bladder was significantly greater using conventional techniques (Cobalt-60/LINAC) than using conformal techniques at 72% and 78% compared to 28% and 22%, respectively. The use of conformal techniques in pelvic radiation therapy is suggested in radiotherapy centers with CT simulators and 3D Radiotherapy Treatment Planning Systems (RTPSs) to decrease some uncertainties in radiotherapy planning. The use of AP/PA pelvic radiation techniques with Cobalt-60 should be limited in body thicknesses equal to or less than 18 cm. When using conformal techniques, delineation should be applied in the small bowel, as it is considered a critical organ according to RTOG

  8. Uniform stable conformal convolutional perfectly matched layer for enlarged cell technique conformal finite-difference time-domain method

    International Nuclear Information System (INIS)

    Wang Yue; Wang Jian-Guo; Chen Zai-Gao

    2015-01-01

    Based on conformal construction of physical model in a three-dimensional Cartesian grid, an integral-based conformal convolutional perfectly matched layer (CPML) is given for solving the truncation problem of the open port when the enlarged cell technique conformal finite-difference time-domain (ECT-CFDTD) method is used to simulate the wave propagation inside a perfect electric conductor (PEC) waveguide. The algorithm has the same numerical stability as the ECT-CFDTD method. For the long-time propagation problems of an evanescent wave in a waveguide, several numerical simulations are performed to analyze the reflection error by sweeping the constitutive parameters of the integral-based conformal CPML. Our numerical results show that the integral-based conformal CPML can be used to efficiently truncate the open port of the waveguide. (paper)

  9. Daily-diary evaluated side-effects of conformal versus conventional prostatic cancer radiotherapy technique

    International Nuclear Information System (INIS)

    Widmark, A.; Fransson, P.; Franzen, L.; Littbrand, B.; Henriksson, R.

    1997-01-01

    Conventional 4-field box radiotherapy technique induces high morbidity for patients with localized prostatic cancer. Using a patient daily diary, the present study compared side-effects after conventional radiotherapy with conformal radiotherapy for prostate cancer. Fifty-eight patients treated with the conventional technique (with or without sucralfate) were compared with 72 patients treated with conformal technique. The patient groups were compared with an age-matched control population. Patients treated with conformal technique were also evaluated regarding acute and late urinary problems. Results showed that patients treated with conformal technique reported significantly fewer side-effects as compared with conventional technique. Patients treated with sucralfate also showed slightly decreased intestinal morbidity in comparison to non-sucralfate group. Acute and late morbidity evaluated by the patients was decreased after conformal radiotherapy as compared with the conventional technique. Sucralfate may be of value if conformal radiotherapy is used for dose escalation in prostatic cancer patients. (orig.)

  10. Solving conformal contacts using multi-Hertzian techniques

    Science.gov (United States)

    Pascal, Jean-Pierre; Soua, Brahim

    2016-06-01

    Recently, publications aiming at wheel-rail contact surveys let readers think that multi-Hertzian methods present severe drawbacks with respect to 'virtual penetration' methods. These surveys criticise multi-Hertzian solutions mainly because presenting 'larger contacts overlaps' and 'frequent secondary contacts near the border of the first contact', both obvious geometric possibilities of which the practical occurrence and eventual inconvenience would remain purely theoretical unless established over definite methods demonstrating poor practical results. Recent surveys all quote Piotrowski-Chollet 2005 survey of wheel-rail contact models that attempted to illustrate defective multi-Hertzian techniques by concentrating on the method initiated by Sauvage in the 1990s and further developed by Pascal. The 2005 paper not only gives no evidence of practical inconveniences of Sauvage's method but also confuses static geometric contact overlaps with the dynamical overlapping of forces. In reality it mixes Sauvage method up with a quite different technique. Thus a clarification is now necessary by reminding what the proper Sauvage technique really is and by showing some of its practical successful applications. The present paper, focusing on determination of normal contact forces in conformal situations, intends to explain clearly the advantages of the unequivocal localisation of secondary ellipses in that multi-Hertzian method which has been developed in INRETS VOCO codes in the 1990s and successfully used by SNCF and ALSTOM in the INRETS-SNCF code, VOCODYM, and later in Pascal's online calculation of railway elastic contacts code. It proved its effectiveness for studying freight wagons derailments as well as rail wear and head-check, unrounded wheels wear, high-speed lines' deformations or TGV comfort. While simulating American ACELA trainsets' behaviour on the US North-East Corridor tracks, prior to actual tests, as part of the commercial contract. It has been also a

  11. Factors influencing incidence of acute grade 2 morbidity in conformal and standard radiation treatment of prostate cancer

    International Nuclear Information System (INIS)

    Hanks, Gerald E.; Schultheiss, Timothy E.; Hunt, Margie A.; Epstein, Barry

    1995-01-01

    Purpose: The fundament hypothesis of conformal radiation therapy is that tumor control can be increased by using conformal treatment techniques that allow a higher tumor dose while maintaining an acceptable level of complications. To test this hypothesis, it is necessary first to estimate the incidence of morbidity for both standard and conformal fields. In this study, we examine factors that influence the incidence of acute grade 2 morbidity in patients treated with conformal and standard radiation treatment for prostate cancer. Methods and Materials: Two hundred and forty-seven consecutive patients treated with conformal technique are combined with and compared to 162 consecutive patients treated with standard techniques. The conformal technique includes special immobilization by a cast, careful identification of the target volume in three dimensions, localization of the inferior border of the prostate using the retrograde urethrogram, and individually shaped portals that conform to the Planning Target Volume (PTV). Univariate analysis compares differences in the incidence of RTOG-EORTC grade two acute morbidity by technique, T stage, age, irradiated volume, and dose. Multivariate logistic regression includes these same variables. Results: In nearly all categories, the conformal treatment group experienced significantly fewer acute grade 2 complications than the standard treatment group. Only volume (prostate ± whole pelvis) and technique (conformal vs. standard) were significantly related to incidence of morbidity on multivariate analysis. When dose is treated as a continuous variable (rather than being dichotomized into two levels), a trend is observed on multivariate analysis, but it does not reach significant levels. The incidence of acute grade 2 morbidity in patients 65 years or older is significantly reduced by use of the conformal technique. Conclusion: The conformal technique is associated with fewer grade 2 acute toxicities for all patients. This

  12. Evaluation of conformal radiotherapy techniques through physics and biologic criteria

    International Nuclear Information System (INIS)

    Bloch, Jonatas Carrero

    2012-01-01

    In the fight against cancer, different irradiation techniques have been developed based on technological advances and aiming to optimize the elimination of tumor cells with the lowest damage to healthy tissues. The radiotherapy planning goal is to establish irradiation technical parameters in order to achieve the prescribed dose distribution over the treatment volumes. While dose prescription is based on radiosensitivity of the irradiated tissues, the physical calculations on treatment planning take into account dosimetric parameters related to the radiation beam and the physical characteristics of the irradiated tissues. To incorporate tissue's radiosensitivity into radiotherapy planning calculations can help particularize treatments and establish criteria to compare and elect radiation techniques, contributing to the tumor control and the success of the treatment. Accordingly, biological models of cellular response to radiation have to be well established. This work aimed to study the applicability of using biological models in radiotherapy planning calculations to aid evaluating radiotherapy techniques. Tumor control probability (TCP) was studied for two formulations of the linear-quadratic model, with and without repopulation, as a function of planning parameters, as dose per fraction, and of radiobiological parameters, as the α/β ratio. Besides, the usage of biological criteria to compare radiotherapy techniques was tested using a prostate planning simulated with Monte Carlo code PENELOPE. Afterwards, prostate planning for five patients from the Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto, USP, using three different techniques were compared using the tumor control probability. In that order, dose matrices from the XiO treatment planning system were converted to TCP distributions and TCP-volume histograms. The studies performed allow the conclusions that radiobiological parameters can significantly influence tumor control

  13. Conformal treatment of prostate cancer with improved targeting: superior prostate-specific antigen response compared to standard treatment

    Energy Technology Data Exchange (ETDEWEB)

    Corn, Benjamin W; Hanks, Gerald E; Schultheiss, Timothy E; Hunt, Margie A; Lee, W Robert; Coia, Lawrence R

    1995-05-15

    Purpose: Conformal radiation therapy (CRT) decreases the morbidity of prostate cancer treatment, but no published data attest to the improved ability of CRT to control disease. Therefore, we compared Prostate-Specific Antigen (PSA) response at 1 year among similarly staged patients treated by conformal techniques to those treated with conventional approaches, looking for an early indicator of tumor response. Method and Materials: Patients with locally advanced disease were treated by pelvic fields followed by prostate field conedowns; those with early stage/low grade disease received only prostate field irradiation. Between October, 1987 and November, 1991, conventional treatments used rectangular beams with or without corner blocks. Neither urethrography nor immobilization casts were used for conventionally treated patients. Between April, 1989 and December, 1992, conformal treatments have used rigid immobilization and Computed Tomography-based, beams-eye-view field design. As such, our conformal approach allowed improved targeting. Median prescribed doses (minimal doses to the Planning Target Volume) were 70 Gy (66-73 Gy) and 70.2 Gy (64.8-75 Gy) for conventionally and conformally treated patients, respectively. Median daily fraction size was 1.8 Gy for conventional treatment and 2.0 Gy for conformal therapy. Baseline PSA data were available on 170 consecutive patients treated conformally and 90 consecutive patients treated conventionally. Results: Among those receiving only prostatic field irradiation, 12-month PSA values returned to normal in 96% and 85% of conformally and conventionally treated patients, respectively, when normalization was defined as {<=} 4 ng/ml (p < 0.03) and in 76% vs. 55% of patients when PSA normalization was defined as {<=} 1.5 ng/ml (p < 0.02). Among those receiving pelvic irradiation prior to prostatic conedown, PSA normalization ({<=} 4 ng/ml) occurred in 82% and 61% (p < 0.01) of conformally and conventionally treated patients

  14. Monte Carlo conformal treatment planning as an independent assessment

    International Nuclear Information System (INIS)

    Rincon, M.; Leal, A.; Perucha, M.; Carrasco, E.; Sanchez-Doblado, F.; Hospital Univ. Virgen Macarena, Sevilla; Arrans, R.; Sanchez-Calzado, J.A.; Errazquin, L.; Medrano, J.C.

    2001-01-01

    The wide range of possibilities available in Radiotherapy with conformal fields cannot be covered experimentally. For this reason, dosimetrical and planning procedures are based on approximate algorithms or systematic measurements. Dose distribution calculations based on Monte Carlo (MC) simulations can be used to check results. In this work, two examples of conformal field treatments are shown: A prostate carcinoma and an ocular lymphoma. The dose distributions obtained with a conventional Planning System and with MC have been compared. Some significant differences have been found. (orig.)

  15. Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer

    International Nuclear Information System (INIS)

    Ercan, T.; Alco, G.; Zengin, F.; Atilla, S.; Dincer, M.; Igdem, S.; Okkan, S.

    2010-01-01

    The aim of this study was to be able to implement the field-in-field intensity-modulated radiotherapy (FiF) technique in our daily practice for breast radiotherapy. To do this, we performed a dosimetric comparison. Treatment plans were produced for 20 consecutive patients. FiF plans and conformal radiotherapy (CRT) plans were compared for doses in the planning target volume (PTV), the dose homogeneity index (DHI), doses in irradiated soft tissue outside the target volume (SST), ipsilateral lung and heart doses for left breast irradiation, and the monitor unit counts (MU) required for treatment. Averaged values were compared using Student's t-test. With FiF, the DHI is improved 7.0% and 5.7%, respectively (P<0.0001) over the bilateral and lateral wedge CRT techniques. When the targeted volumes received 105% and 110% of the prescribed dose in the PTV were compared, significant decreases are found with the FiF technique. With the 105% dose, the SST, heart, and ipsilateral lung doses and the MU counts were also significantly lower with the FiF technique. The FiF technique, compared to CRT, for breast radiotherapy enables significantly better dose distribution in the PTV. Significant differences are also found for soft tissue volume, the ipsilateral lung dose, and the heart dose. Considering the decreased MUs needed for treatment, the FiF technique is preferred over tangential CRT. (author)

  16. Conformation radiotherapy and conformal radiotherapy

    International Nuclear Information System (INIS)

    Morita, Kozo

    1999-01-01

    In order to coincide the high dose region to the target volume, the 'Conformation Radiotherapy Technique' using the multileaf collimator and the device for 'hollow-out technique' was developed by Prof. S. Takahashi in 1960. This technique can be classified a type of 2D-dynamic conformal RT techniques. By the clinical application of this technique, the late complications of the lens, the intestine and the urinary bladder after radiotherapy for the maxillary cancer and the cervical cancer decreased. Since 1980's the exact position and shape of the tumor and the surrounding normal tissues can be easily obtained by the tremendous development of the CT/MRI imaging technique. As a result, various kinds of new conformal techniques such as the 3D-CRT, the dose intensity modulation, the tomotherapy have been developed since the beginning of 1990'. Several 'dose escalation study with 2D-/3D conformal RT' is now under way to improve the treatment results. (author)

  17. Irradiation of head-and-neck tumors with intensity modulated radiotherapy (IMRT). Comparison between two IMRT techniques with 3D conformal irradiation

    International Nuclear Information System (INIS)

    Heeger, Jonas

    2013-01-01

    For 12 patients with inoperable head-neck carcinoma that were treated with 3D conformal irradiation techniques additional irradiation plans using IMRT were developed. It was shown that the IMRT techniques are superior to the 3D conformal technique. The new rapid arc technique is unclear with respect to the critical organs (parotid glands, spinal canal and mandibles) but is significantly advantageous for the other normal tissue with respect to conformity (steeper dose gradients) and thus radiation dose reduction. The resulting lower irradiation time and the reduced radiation exposure being important for the treatment economy and patients' comfort should favor the more planning intensive rapid arc technique.

  18. A computer-controlled conformal radiotherapy system. III: graphical simulation and monitoring of treatment delivery

    International Nuclear Information System (INIS)

    Kessler, Marc L.; McShan, Daniel L.; Fraass, Benedick A.

    1995-01-01

    Purpose: Safe and efficient delivery of radiotherapy using computer-controlled machines requires new procedures to design and verify the actual delivery of these treatments. Graphical simulation and monitoring techniques for treatment delivery have been developed for this purpose. Methods and Materials: A graphics-based simulator of the treatment machine and a set of procedures for creating and manipulating treatment delivery scripts are used to simulate machine motions, detect collisions, and monitor machine positions during treatment. The treatment delivery simulator is composed of four components: a three-dimensional dynamic model of the treatment machine; a motion simulation and collision detection algorithm, user-interface widgets that mimic the treatment machine's control and readout devices; and an icon-based interface for creating and manipulating treatment delivery scripts. These components are used in a stand-alone fashion for interactive treatment delivery planning and integrated with a machine control system for treatment implementation and monitoring. Results: A graphics-based treatment delivery simulator and a set of procedures for planning and monitoring computer-controlled treatment delivery have been developed and implemented as part of a comprehensive computer-controlled conformal radiotherapy system. To date, these techniques have been used to design and help monitor computer-controlled treatments on a radiotherapy machine for more than 200 patients. Examples using these techniques for treatment delivery planning and on-line monitoring of machine motions during therapy are described. Conclusion: A system that provides interactive graphics-based tools for defining the sequence of machine motions, simulating treatment delivery including collision detection, and presenting the therapists with continual visual feedback from the treatment machine has been successfully implemented for routine clinical use as part of an overall system for computer

  19. Techniques of Wastewater Treatment

    Indian Academy of Sciences (India)

    of Chemical Engineering in UDCT and works ... tional methods of treatment. Currently the need is ... temperature causes the organic molecule to undergo oxidative degradation. ... When ultrasound is applied to effluent, water undergoes ther-.

  20. Parotid gland sparing radiotherapy technique using 3-D conformal radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lim, Ji Hoon; Kim, Gwi Eon; Keum, Ki Chang; Suh, Chang Ok; Lee, Sang Wook; Park, Hee Chul; Cho, Jae Ho; Chang, Sei Kyung; Loh, Juhn Kyu

    2000-01-01

    Although using the high energy photon beam with conventional parallel-opposed beams radio-therapy for nasopgaryngeal carcinoma, radiation-induced xerostomia is a troublesome problem for patients. We conducted this study to explore a new parotid gland sparing technique in 3-D conformal radiotherapy (3-DCRT) in an effort to prevent the radiation-induced xerostomia. We performed three different planning for four clinically node-negative nasopharyngeal cancer patients with different location of tumor(intracranial extension, nasal cavity extension, oropharyngeal extension, parapharyngeal extension), and intercompared the plans. Total prescription dose was 70.2 Gy to the isocenter. For plan-A, 2-D parallel opposing fields, a conventional radiotherapy technique, were employed. For plan-B, 2-D parallel opposing fields were used up until 54 Gy and afterwards 3-D non-coplanar beams were used. For plan-C, the new technique, 54Gy was delivered by 3-D conformal 3-port beams (AP and both lateral ports with wedge compensator, shielding both superficial lobes of parotid glands at the AP beam using BEV) from the beginning of the treatment and early spinal cord block (at 36 Gy) was performed. And bilateral posterior necks were treated with electron after 36 Gy. After 54 Gy, non-coplanar beams were used for cone-down plan. We intercompared dose statistics (Dmax, Dmin, Dmean, D95, D05, V95, V05, Volume receiving 46 Gy) and dose volume histograms (DVH) of tumor and normal tissues and NTCP values of parotid glands for the above three plans. For all patients, the new technique (plan-C) was comparable or superior to the other plans in target volume isodose distribution and dose statistics and it has more homogenous target volume coverage. The new technique was most superior to the other plans in parotid glands sparing (volume receiving 46 Gy: 100, 98, 69% for each plan-A, B and C). And it showed the lowest NTCP value of parotid glands in all patients (range of NTCP; 96-100%, 79-99%, 51

  1. Conformal three dimensional radiotherapy treatment planning in Lund

    Energy Technology Data Exchange (ETDEWEB)

    Knoos, T; Nilsson, P [Lund Univ. (Sweden). Dept. of Radiation Physics; Anders, A [Lund Univ. (Sweden). Dept. of Oncology

    1995-12-01

    The use of conformal therapy is based on 3-dimensional treatment planning as well as on methods and routines for 3-dimensional patient mapping, 3-dimensional virtual simulation and others. The management of patients at the Radiotherapy Department at the University Hospital in Lund (Sweden) is discussed. About 2100 new patients are annually treated with external radiotherapy using seven linear accelerators. Three of the accelerators have dual photon energies and electron treatment facilities. A multi-leaf collimator as well as an electronic portal imaging device are available on one machine. Two simulators and an in-house CT-scanner are used for treatment planning. From 1988 to 1992 Scandiplan (Umplan) was used. Since 1992, the treatment planning system is TMS (HELAX AB, Sweden), which is based on the pencil beam algorithm of Ahnesjo. The calculations use patient modulated accelerator specific energy fluence spectra which are compiled with pencil beams from Monte Carlo generated energy absorption kernels. Heterogeneity corrections are performed with results close to conventional algorithms. Irregular fields, either from standard or individual blocks and from multi-leaf collimators are handled by the treatment planning system. The field shape is determined conveniently using the beam`s eye view. The final field shape is exported electronically to either the block cutting machine or the multileaf collimator control computer. All patient fields are checked against the beam`s eye view during simulation using manual methods. Treatment verification is performed by portal films and in vivo dosimetry with silicon diodes or TL-dosimetry. Up to now, approximately 4400 patients have received a highly individualized 3-dimensional conformal treatment.

  2. Conformal three dimensional radiotherapy treatment planning in Lund

    International Nuclear Information System (INIS)

    Knoos, T.; Nilsson, P.; Anders, A.

    1995-01-01

    The use of conformal therapy is based on 3-dimensional treatment planning as well as on methods and routines for 3-dimensional patient mapping, 3-dimensional virtual simulation and others. The management of patients at the Radiotherapy Department at the University Hospital in Lund (Sweden) is discussed. About 2100 new patients are annually treated with external radiotherapy using seven linear accelerators. Three of the accelerators have dual photon energies and electron treatment facilities. A multi-leaf collimator as well as an electronic portal imaging device are available on one machine. Two simulators and an in-house CT-scanner are used for treatment planning. From 1988 to 1992 Scandiplan (Umplan) was used. Since 1992, the treatment planning system is TMS (HELAX AB, Sweden), which is based on the pencil beam algorithm of Ahnesjo. The calculations use patient modulated accelerator specific energy fluence spectra which are compiled with pencil beams from Monte Carlo generated energy absorption kernels. Heterogeneity corrections are performed with results close to conventional algorithms. Irregular fields, either from standard or individual blocks and from multi-leaf collimators are handled by the treatment planning system. The field shape is determined conveniently using the beam's eye view. The final field shape is exported electronically to either the block cutting machine or the multileaf collimator control computer. All patient fields are checked against the beam's eye view during simulation using manual methods. Treatment verification is performed by portal films and in vivo dosimetry with silicon diodes or TL-dosimetry. Up to now, approximately 4400 patients have received a highly individualized 3-dimensional conformal treatment

  3. Bolus electron conformal therapy for the treatment of recurrent inflammatory breast cancer: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Michelle M., E-mail: mmkim@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Kudchadker, Rajat J.; Kanke, James E.; Zhang, Sean; Perkins, George H. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-07-01

    The treatment of locoregionally recurrent breast cancer in patients who have previously undergone radiation therapy is challenging. Special techniques are often required that both eradicate the disease and minimize the risks of retreatment. We report the case of a patient with an early-stage left breast cancer who developed inflammatory-type recurrence requiring re-irradiation of the chest wall using bolus electron conformal therapy with image-guided treatment delivery. The patient was a 51-year-old woman who had undergone lumpectomy, axillary lymph node dissection, and adjuvant whole-breast radiation therapy for a stage I left breast cancer in June 1998. In March 2009, she presented at our institution with biopsy-proven recurrent inflammatory carcinoma and was aggressively treated with multi-agent chemotherapy followed by mastectomy that left a positive surgical margin. Given the patient's prior irradiation and irregular chest wall anatomy, bolus electron conformal therapy was used to treat her chest wall and draining lymphatics while sparing the underlying soft tissue. The patient still had no evidence of disease 21 months after treatment. Our results indicate that bolus electron conformal therapy is an accessible, effective radiation treatment approach for recurrent breast cancer in patients with irregular chest wall anatomy as a result of surgery. This approach may complement standard techniques used to reduce locoregional recurrence in the postmastectomy setting.

  4. Three-Dimensional Conformal Simultaneously Integrated Boost Technique for Breast-Conserving Radiotherapy

    International Nuclear Information System (INIS)

    Laan, Hans Paul van der; Dolsma, Wil V.; Maduro, John H.; Korevaar, Erik W.; Hollander, Miranda; Langendijk, Johannes A.

    2007-01-01

    Purpose: To compare the target coverage and normal tissue dose with the simultaneously integrated boost (SIB) and the sequential boost technique in breast cancer, and to evaluate the incidence of acute skin toxicity in patients treated with the SIB technique. Methods and Materials: Thirty patients with early-stage left-sided breast cancer underwent breast-conserving radiotherapy using the SIB technique. The breast and boost planning target volumes (PTVs) were treated simultaneously (i.e., for each fraction, the breast and boost PTVs received 1.81 Gy and 2.3 Gy, respectively). Three-dimensional conformal beams with wedges were shaped and weighted using forward planning. Dose-volume histograms of the PTVs and organs at risk with the SIB technique, 28 x (1.81 + 0.49 Gy), were compared with those for the sequential boost technique, 25 x 2 Gy + 8 x 2 Gy. Acute skin toxicity was evaluated for 90 patients treated with the SIB technique according to Common Terminology Criteria for Adverse Events, version 3.0. Results: PTV coverage was adequate with both techniques. With SIB, more efficiently shaped boost beams resulted in smaller irradiated volumes. The mean volume receiving ≥107% of the breast dose was reduced by 20%, the mean volume outside the boost PTV receiving ≥95% of the boost dose was reduced by 54%, and the mean heart and lung dose were reduced by 10%. Of the evaluated patients, 32.2% had Grade 2 or worse toxicity. Conclusion: The SIB technique is proposed for standard use in breast-conserving radiotherapy because of its dose-limiting capabilities, easy implementation, reduced number of treatment fractions, and relatively low incidence of acute skin toxicity

  5. Comparison of Optimised Treatment Plans for Radiosurgery and Conformal Radiotherapy

    National Research Council Canada - National Science Library

    Kulik, C

    2001-01-01

    ..., it is interesting to compare the different techniques to evaluate their effectiveness, This comparison involves 8 clinical cases, For each treatment modality, we compare indexes defined in the international...

  6. [Technique of complex mammary irradiation: Mono-isocentric 3D conformational radiotherapy and helical tomotherapy].

    Science.gov (United States)

    Vandendorpe, B; Guilbert, P; Champagne, C; Antoni, T; Nguyen, T D; Gaillot-Petit, N; Servagi Vernat, S

    2017-12-01

    To evaluate the dosimetric contribution of helical tomotherapy for breast cancers compared with conformal radiotherapy in mono-isocentric technique. For 23 patients, the dosimetric results in mono-isocentric 3D conformational radiotherapy did not satisfy the constraints either of target volumes nor organs at risk. A prospective dosimetric comparison between mono-isocentric 3D conformational radiotherapy and helical tomotherapy was therefore carried out. The use of helical tomotherapy showed a benefit in these 23 patients, with either an improvement in the conformity index or homogeneity, but with an increase in low doses. Of the 23 patients, two had pectus excavatum, five had past thoracic irradiation and two required bilateral irradiation. The other 14 patients had a combination of morphology and/or indication of lymph node irradiation. For these patients, helical tomotherapy was therefore preferred to mono-isocentric 3D conformational radiotherapy. Tomotherapy appears to provide better homogeneity and tumour coverage. This technique of irradiation may be justified in the case of morphological situations such as pectus exavatum and in complex clinical situations. In other cases, conformal radiotherapy in mono-isocentric technique remains to be favoured. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  7. Results of different modes conformal radiotherapy in treatment of cervical cancer

    International Nuclear Information System (INIS)

    Baranovs'ka, L.M.; Yivankova, V.S.; Khrulenko, T.V.; Skomorokhova, T.V.; Gorelyina, G.L.

    2017-01-01

    Development of techniques for cytotoxic treatment applying different modes of conformal radiotherapy, brachytherapy and high-energy (high dose rate - HDR) is one of the promising areas of optimization and efficiency of conservative treatment of patients with regional forms of cervical cancer. At Radiation Oncology Department, National Cancer Institute, 89 patients with stage 2b-3b cervical cancer, aged 29 to 70, underwent examination and combined radiotherapy course. The patients were divided into 2 main groups (56 patients) depending on the mode of developed conformal radiation therapy, and a control group made up by 33 patients (classic, default conformal radiotherapy). Results. Along with external beam radiotherapy, the patients of Group 2 were provided with conformal radiotherapy carried out by means of the linear accelerator of electrons in the mode of enhanced multi fractionation of irradiation dose applied to the small pelvis area (tumor and lymph efflux channels) with the single tumor dose 1.3 Gy twice per day once 4-6 hours up to the total radiation dose of 45 Gy applied to the small pelvis lymph nodes. The patients of Group 1 and the ones of the control group underwent conformal radiotherapy in the mode of standard fractionation applied to the small pelvis area with the single tumor dose of 1.8 Gy up to the total radiation dose of 45 Gy. Conformal radiotherapy was carried out for the patients of Group 1 associated with chemoradiomodifiers (tegafur, cisplatin). At the stage 2 of combined radiotherapy course, all patients underwent HDR brachytherapy via Co60 source in the mode of the single tumor dose of 5 Gy at point A up to the total radiation dose of 35-40 Gy. Therefore, employing accelerated mode of multifractiation in conformal radiotherapy of patients with regional cervical cancer makes it possible to enhance canrcinocidal irradiation doses applied to a tumor, and an interval between radiotherapy fractions provides conditions for initiation of

  8. Localized field conformation radiotherapy combined with endocrine therapy for the treatment of prostate cancer

    International Nuclear Information System (INIS)

    Karasawa, Katsuyuki; Kaizu, Toshihide; Kurosaki, Hiromasa; Tanaka, Yoshiaki

    1999-01-01

    To improve the quality of life (QOL) of the patients with prostate cancer, we limit the radiotherapy target volume to the prostate and seminal vesicles while using endocrine therapy towards the disease outside the target volume. Radiotherapy technique was rotation conformation technique with computer-controlled multileaf collimators to the total doses of up to 66-70 Gy. Among 145 evaluable cases with the median age of 74, overall and cause-specific 5-year survival rates were 59.3% and 84.1%, respectively, and the relative survival rate of the Stage A-C cases was 100%. The two thirds (33/50) of the deaths were not of prostate cancer. The rate of severe complication was 1.4%. As for QOL, the rate of impotence was 90%, however, the patients' overall satisfaction towards the treatment was 90%. From this analysis, this combined treatment seems beneficial in the treatment of prostate cancer. (author)

  9. A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Oliver, Mike; Chen, Jeff; Wong, Eugene; Van Dyk, Jake; Perera, Francisco

    2007-01-01

    Purpose and background: Conventional early breast cancer treatment consists of a lumpectomy followed by whole breast radiation therapy. Accelerated partial breast irradiation (APBI) is an investigational approach to post-lumpectomy radiation for early breast cancer. The purpose of this study is to compare four external beam APBI techniques, including tomotherapy, with conventional whole breast irradiation for their radiation conformity index, dose homogeneity index, and dose to organs at risk. Methods and materials: Small-field tangents, three-dimensional conformal radiation therapy, intensity-modulated radiation therapy and helical tomotherapy were compared for each of 15 patients (7 right, 8 left). One radiation conformity and two dose homogeneity indices were used to evaluate the dose to the target. The mean dose to organs at risk was also evaluated. Results: All proposed APBI techniques improved the conformity index significantly over whole breast tangents while maintaining dose homogeneity and without a significant increase in dose to organs at risk. Conclusion: The four-field IMRT plan produced the best dosimetric results; however this technique would require appropriate respiratory motion management. An alternative would be to use a four-field conformal technique that is less sensitive to the effects of respiratory motion

  10. Incidence of and factors related to late complications in conformal and conventional radiation treatment of cancer of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Schultheiss, Timothy E; Hanks, Gerald E; Hunt, Margie A; Lee, W Robert

    1995-06-15

    Purpose: The fundament hypothesis of conformal radiation therapy is that tumor control can be increased by using conformal treatment techniques that allow a higher tumor dose while maintaining an acceptable level of complications. To test this hypothesis, it is necessary first to estimate the incidence of morbidity for both standard and conformal fields. In this study, we examine factors that influence the incidence of late Grade 3 and 4 morbidity in patients treated with conformal and standard radiation treatment for prostate cancer. Methods and Materials: Six hundred sixteen consecutive patients treated with conformal or standard techniques between 1986 and 1994 to doses greater than 65 Gy and with more than 3 months follow-up were analyzed. No patients treated with prostatectomies were included in the analysis. The conformal technique includes special immobilization by a cast, careful identification of the target volume in three dimensions, localization of the inferior border of the prostate using a retrograde urethrogram, and individually shaped portals that conform to the Planning Target Volume (PTV). Multivariate analysis using a proportional hazards model compares differences in the incidence of Radiation Therapy Oncology Group/European Organization for Research and Center Treatment (RTOG/EORTC) Grade 3 and 4 late gastrointestinal (GI) and genitourinary (GU) morbidity by technique, T-stage, grade, age, hormonal treatment, irradiated volume, dose, and comorbid conditions. Grade 3 rectal bleeding was defined as requiring three or more cautery procedures. Results: The overall actuarial incidence of genitourinary (GU) toxicities at 5 years was 3.4%, with the crude incidence being six cases in 616 patients satisfying the selection criteria; for gastrointestinal (GI) toxicities, the overall actuarial incidence was 2.7%, with the crude incidence being 13 cases out of 616 patients. The average time to complication for our patients was 12.8 months for GI toxicity and

  11. FXG dosimeter response for three-dimensional conformal radiotherapy using different evaluation techniques

    International Nuclear Information System (INIS)

    Cavinato, Christianne C.; Campos, Leticia L.; Souza, Benedito H.; Carrete Junior, Henrique; Daros, Kellen A.C.; Medeiros, Regina B.; Giordani, Adelmo J.

    2011-01-01

    This work aims to compare the dose-response of the Fricke xylenol gel (FXG) dosimeter developed at IPEN using 270 Bloom gelatin from porcine skin made in Brazil evaluated using the magnetic resonance imaging (MRI) technique with the dosimetric response evaluated using the optical absorption (OA) spectrophotometry technique, in order to verify the possibility of quality assurance (QA) and reproducibility of FXG dosimeter to be carried out routinely using the OA technique for three-dimensional conformal radiotherapy (3DCRT) application using a 6 MV photons linear accelerator. The response in function of the absorbed dose of FXG dosimeter developed at IPEN presents linear behavior in clinical interest dose range when irradiated with Co-60 gamma radiation and 6 MV photons and evaluated using the MRI and OA techniques. The results indicate that the optical technique can be used for QA of FXG dosemeter when used in the possible application in QA of 3DCRT. (author)

  12. FXG dosimeter response for three-dimensional conformal radiotherapy using different evaluation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Cavinato, Christianne C.; Campos, Leticia L., E-mail: ccavinato@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Souza, Benedito H.; Carrete Junior, Henrique; Daros, Kellen A.C.; Medeiros, Regina B., E-mail: bhsouza@unifesp.b, E-mail: daros.kellen@unifesp.b, E-mail: rbitel-li.ddi@epm.b [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Dept. de Diagnostico por Imagem; Giordani, Adelmo J. [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Servico de Radioterapia

    2011-07-01

    This work aims to compare the dose-response of the Fricke xylenol gel (FXG) dosimeter developed at IPEN using 270 Bloom gelatin from porcine skin made in Brazil evaluated using the magnetic resonance imaging (MRI) technique with the dosimetric response evaluated using the optical absorption (OA) spectrophotometry technique, in order to verify the possibility of quality assurance (QA) and reproducibility of FXG dosimeter to be carried out routinely using the OA technique for three-dimensional conformal radiotherapy (3DCRT) application using a 6 MV photons linear accelerator. The response in function of the absorbed dose of FXG dosimeter developed at IPEN presents linear behavior in clinical interest dose range when irradiated with Co-60 gamma radiation and 6 MV photons and evaluated using the MRI and OA techniques. The results indicate that the optical technique can be used for QA of FXG dosemeter when used in the possible application in QA of 3DCRT. (author)

  13. Dose escalation with 3D conformal treatment: five year outcomes, treatment optimization, and future directions

    International Nuclear Information System (INIS)

    Hanks, Gerald E.; Hanlon, Alexandra L. M.S.; Schultheiss, Timothy E.; Pinover, Wayne H.; Movsas, Benjamin; Epstein, Barry E.; Hunt, Margie

    1998-01-01

    Purpose: To report the 5-year outcomes of dose escalation with 3D conformal treatment (3DCRT) of prostate cancer. Methods and Materials: Two hundred thirty-two consecutive patients were treated with 3DCRT alone between 6/89 and 10/92 with ICRU reporting point dose that increased from 63 to 79 Gy. The median follow-up was 60 months, and any patient free of clinical or biochemical evidence of disease was termed bNED. Biochemical failure was defined as prostate-specific antigen (PSA) rising on two consecutive recordings and exceeding 1.5 ng/ml. Morbidity was reported by the Radiation Therapy Oncology Group (RTOG) scale, the Late Effects Normal Tissue (LENT) scale, and a Fox Chase modification of the latter (FC-LENT). All patients were treated with a four-field technique with a 1 cm clinical target volume (CTV) to planning target volume (PTV) margin to the prostate or prostate boost; the CTV and gross tumor volume (GTV) were the same. Actuarial rates of outcome were calculated by Kaplan-Meier and cumulative incidence methods and compared using the log rank and Gray's test statistic, respectively. Cox regression models were used to establish prognostic factors predictive of the various measures of outcome. Five-year Kaplan-Meier bNED rates were utilized by dose group to estimate logit response models for bNED and late morbidity. Results: PSA 10 ng/ml based on 5-year bNED results. No dose response was observed for patients with pretreatment PSA 10 ng/ml strongly suggests that clinical trials employing radiation should investigate the use of 3DCRT and prostate doses of 76-80 Gy

  14. Processing ultrafine-grained Aluminum alloy using Multi-ECAP-Conform technique

    International Nuclear Information System (INIS)

    Fakhretdinova, Elvira; Raab, Georgy; Valiev, Ruslan; Ryzhikov, Oleg

    2014-01-01

    The stress-strained state (SSS), contact and force parameters of a new SPD technique – Multi-ECAP-Conform – have been studied. The new technique ensures a high level of accumulated strain □=4...5 per one processing cycle. Physical and computer modeling by finite element method in Deform-3D software was applied to evaluate the parameters. It is shown that the results of physical and computer modeling correlate with each other. Equipment has been upgraded, and experimental samples of Al-Mg-Si system alloy have been processed

  15. Conformational Analysis of Misfolded Protein Aggregation by FRET and Live-Cell Imaging Techniques

    Directory of Open Access Journals (Sweden)

    Akira Kitamura

    2015-03-01

    Full Text Available Cellular homeostasis is maintained by several types of protein machinery, including molecular chaperones and proteolysis systems. Dysregulation of the proteome disrupts homeostasis in cells, tissues, and the organism as a whole, and has been hypothesized to cause neurodegenerative disorders, including amyotrophic lateral sclerosis (ALS and Huntington’s disease (HD. A hallmark of neurodegenerative disorders is formation of ubiquitin-positive inclusion bodies in neurons, suggesting that the aggregation process of misfolded proteins changes during disease progression. Hence, high-throughput determination of soluble oligomers during the aggregation process, as well as the conformation of sequestered proteins in inclusion bodies, is essential for elucidation of physiological regulation mechanism and drug discovery in this field. To elucidate the interaction, accumulation, and conformation of aggregation-prone proteins, in situ spectroscopic imaging techniques, such as Förster/fluorescence resonance energy transfer (FRET, fluorescence correlation spectroscopy (FCS, and bimolecular fluorescence complementation (BiFC have been employed. Here, we summarize recent reports in which these techniques were applied to the analysis of aggregation-prone proteins (in particular their dimerization, interactions, and conformational changes, and describe several fluorescent indicators used for real-time observation of physiological states related to proteostasis.

  16. Dose conformation to the spine during palliative treatments using dynamic wedges

    Energy Technology Data Exchange (ETDEWEB)

    Ormsby, Matthew A., E-mail: Matthew.Ormsby@usoncology.com [West Texas Cancer Center at Medical Center Hospital, Odessa, TX (United States); Herndon, R. Craig; Kaczor, Joseph G. [West Texas Cancer Center at Medical Center Hospital, Odessa, TX (United States)

    2013-07-01

    Radiation therapy is commonly used to alleviate pain associated with metastatic disease of the spine. Often, isodose lines are manipulated using dynamic or physical wedges to encompass the section of spine needing treatment while minimizing dose to normal tissue. We will compare 2 methods used to treat the entire thoracic spine. The first method treats the thoracic spine with a single, nonwedged posterior-anterior (PA) field. Dose is prescribed to include the entire spine. Isodose lines tightly conform to the top and bottom vertebrae, but vertebrae between these 2 received more than enough coverage. The second method uses a combination of wedges to create an isodose line that mimics the curvature of the thoracic spine. This “C”-shaped curvature is created by overlapping 2 fields with opposing dynamic wedges. Machine constraints limit the treatment length and therefore 2 isocenters are used. Each of the 2 PA fields contributes a portion of the total daily dose. This technique creates a “C”-shaped isodose line that tightly conforms to the thoracic spine, minimizing normal tissue dose. Spinal cord maximum dose is reduced, as well as mean dose to the liver, esophagus, and heart.

  17. Acute toxicity in pelvic radiotherapy; a randomised trial of conformal versus conventional treatment

    International Nuclear Information System (INIS)

    Tait, Diana M.; Nahum, Alan E.; Meyer, Lesley C.; Law, Matthew; Dearnaley, David P.; Horwich, Alan; Mayles, W. Philip; Yarnold, John R.

    1997-01-01

    Background: A prospective, randomized clinical trial to assess the effect of reducing the volume of irradiated normal tissue on acute reactions in pelvic radiotherapy accrued 266 evaluable patients between 1988 and 1993. Purpose: This is the definitive analysis to assess the differences between the conformal and conventional arms of the trial. Materials and methods: In both arms, patients were treated with 6 MV X-rays using a 3-field technique (in all but 5 cases) consisting of an anterior and two wedged lateral or posterior oblique fields; in the conventional arm, rectangular fields were employed, whereas in the conformal arm, the fields were shaped with customized blocks drawn according to the beam's-eye-view of the target volume. The most common dosage was 65 Gy in 2-Gy fractions 5 times a week, although a subgroup (of ca. bladder patients) were treated with 30-36 Gy in once-a-week 6 Gy fractions. Each patient completed a comprehensive acute toxicity scoring questionnaire concentrating on bowel and bladder problems, tiredness and nausea, before the start of treatment, weekly during and for 3 weeks after the end of treatment and then monthly for a further 2 months. Compliance was excellent. Results: There were no differences between the patients in the two arms with respect to age, gender, tumour type (52% prostate, 41% bladder, 5% rectum, 2% other) fractionation/dosage, anterior field size, weight, or baseline symptoms. Substantial differences in normal-tissue volumes (rectum, bladder, etc.) were achieved: median high-dose volume (HDV) of 689 cm 3 for the conformal technique versus 792 cm 3 for the conventional. A clear pattern of an increase in symptoms during RT, followed by a decrease after RT, was observed for the patient group as a whole. However, a very extensive analysis has not revealed any (statistically) significant differences between the two arms in level of symptoms, nor in medication prescribed. The disparity between our findings and those of other

  18. Optimal 3-D conformal treatment planning of posterior lateral supratentorial tumors

    International Nuclear Information System (INIS)

    Gius, David; Klein, Eric; Oehmke, Fred

    1995-01-01

    Purpose/Objective: The ability to treat the brain to greater doses is limited by normal brain tissue tolerance. With the use of 3-dimensional treatment planning dose escalation will result in increased target dose while sparing normal tissue. Treatment of the supratentorial region of the brain presents several unique difficulties due to the changing contour of the calvarium, which are especially noticeable with treatment to the posterior lateral quadrant. The use of a single wedge beam is sub-optimal and a more appropriate solution would employ a two tier wedge arrangement to better conform the isodoses around the target volume. In the past it has only been possible to use a single wedge during treatment with a single port, however, the dynamic wedge presents the opportunity to employ a two tier wedge system by simultaneously using conventional and dynamic wedging. Methods and Materials: An anthropomorphic phantom with a lesion located in the posterior lateral aspect of the brain where the external surface slopes at a maximum was configured. CT generated contours outlined the external surface, normal anatomy, gross tumor, and target volumes. We used the beam's-eye-view projection from the 3D planning system to derive the conformal beams. A standard opposed lateral and posterior oblique wedge pair beam arrangements, were compared to a three field technique (PA, lateral, and vertex) which used both a single wedge arrangement and a two-tier wedge plan. Treatment plans were evaluated by calculating isodose distribution, DVH, TCP, and NTCP. Each beam arrangement was used to treat our phantom with film placed in between the phantom layers at the tumor levels to confirm the accuracy of the 3-D system calculations. Results: The three field, two-tier wedge technique isodose distribution was significantly superior when compared to the standard 2-D plans, and a moderate improvement over the three field, single wedge technique in terms of conforming dose to the tumor and

  19. Open table-top device positioning technique to reduce small bowel obstruction. Positioning accuracy and impact on conformal radiation therapy techniques

    International Nuclear Information System (INIS)

    Rudat, V.; Flentje, M.; Engenhart, R.; Metzger, M.; Wannenmacher, M.

    1995-01-01

    The immobilization error of patients positioned on the opern table-top device in prone prosition as well as the movement of the small bowel out of the pelvis by this positioning technique was determined. The positioning error is of special importance for the 3-dimensional treatment planning for conformal radiotherapy. The positioning error was determined by superposing 106 portal films with the corresponding simultor films from 21 patients with carcinoma of the rectum who received 3D-planned conformal radiotherapy (o-field technique with irregular blocks). The movement of the small bowel out of the pelvis was studied by comparing simulator films after barium swallow in supine and open table-top position as well with 3D-treatment plans of the same patient in both positions in 3 cases. The positioning error along the medio-lateral, dorso-ventral und cranio-caudal axis was 1.4/-0.6/1.8 mm and the standard deviation 4.4/6.8/6.3 mm, respectively. In comparison to the supine position more rotation errors in the sagittal view were observed (37% and 9% respectively) with a media of 5.1 . Six out of 22 patients showed no adhesions of the small bowel and a complete movement out of the tratment field was achieved. 14 out of 16 Patients with adhesions revealed a partial movement of the small bowel out of the treatment field. Comparing 3D-treatment plans in both positions again demonstrated a marked reduction of the irradiated small bowel volume with the use of the open table-top decive. (orig.) [de

  20. Conformity index: A review

    International Nuclear Information System (INIS)

    Feuvret, Loic; Noel, Georges; Mazeron, Jean-Jacques; Bey, Pierre

    2006-01-01

    We present a critical analysis of the conformity indices described in the literature and an evaluation of their field of application. Three-dimensional conformal radiotherapy, with or without intensity modulation, is based on medical imaging techniques, three-dimensional dosimetry software, compression accessories, and verification procedures. It consists of delineating target volumes and critical healthy tissues to select the best combination of beams. This approach allows better adaptation of the isodose to the tumor volume, while limiting irradiation of healthy tissues. Tools must be developed to evaluate the quality of proposed treatment plans. Dosimetry software provides the dose distribution in each CT section and dose-volume histograms without really indicating the degree of conformity. The conformity index is a complementary tool that attributes a score to a treatment plan or that can compare several treatment plans for the same patient. The future of conformal index in everyday practice therefore remains unclear

  1. Optimization of stereotactically-guided conformal treatment planning of sellar and parasellar tumors, based on normal brain dose volume histograms

    International Nuclear Information System (INIS)

    Perks, Julian R.; Jalali, Rakesh; Cosgrove, Vivian P.; Adams, Elizabeth J.; Shepherd, Stephen F.; Warrington, Alan P.; Brada, Michael

    1999-01-01

    Purpose: To investigate the optimal treatment plan for stereo tactically-guided conformal radiotherapy (SCRT) of sellar and parasellar lesions, with respect to sparing normal brain tissue, in the context of routine treatment delivery, based on dose volume histogram analysis. Methods and Materials: Computed tomography (CT) data sets for 8 patients with sellar- and parasellar-based tumors (6 pituitary adenomas and 2 meningiomas) have been used in this study. Treatment plans were prepared for 3-coplanar and 3-, 4-, 6-, and 30-noncoplanar-field arrangements to obtain 95% isodose coverage of the planning target volume (PTV) for each plan. Conformal shaping was achieved by customized blocks generated with the beams eye view (BEV) facility. Dose volume histograms (DVH) were calculated for the normal brain (excluding the PTV), and comparisons made for normal tissue sparing for all treatment plans at ≥80%, ≥60%, and ≥40% of the prescribed dose. Results: The mean volume of normal brain receiving ≥80% and ≥60% of the prescribed dose decreased by 22.3% (range 14.8-35.1%, standard deviation σ = 7.5%) and 47.6% (range 25.8-69.1%, σ 13.2%), respectively, with a 4-field noncoplanar technique when compared with a conventional 3-field coplanar technique. Adding 2 further fields, from 4-noncoplanar to 6-noncoplanar fields reduced the mean normal brain volume receiving ≥80% of the prescribed dose by a further 4.1% (range -6.5-11.8%, σ = 6.4%), and the volume receiving ≥60% by 3.3% (range -5.5-12.2%, σ = 5.4%), neither of which were statistically significant. Each case must be considered individually however, as a wide range is seen in the volume spared when increasing the number of fields from 4 to 6. Comparing the 4- and 6-field noncoplanar techniques to a 30-field conformal field approach (simulating a dynamic arc plan) revealed near-equivalent normal tissue sparing. Conclusion: Four to six widely spaced, fixed-conformal fields provide the optimum class solution

  2. Efficient CT simulation of the four-field technique for conformal radiotherapy of prostate carcinoma

    International Nuclear Information System (INIS)

    Valicenti, Richard K.; Waterman, Frank M.; Croce, Raymond J.; Corn, Benjamin; Suntharalingam, Nagalingam; Curran, Walter J.

    1997-01-01

    Purpose: Conformal radiotherapy of prostate carcinoma relies on contouring of individual CT slices for target and normal tissue localization. This process can be very time consuming. In the present report, we describe a method to more efficiently localize pelvic anatomy directly from digital reconstructed radiographs (DRRs). Materials and Methods: Ten patients with prostate carcinoma underwent CT simulation (the spiral mode at 3 mm separation) for conformal four-field 'box' radiotherapy. The bulbous urethra and bladder were opacified with iodinated contrast media. On lateral and anteroposterior DRRs, the volume of interest (VOI) was restricted to 1.0-1.5 cm tissue thickness to optimize digital radiograph reconstruction of the prostate and seminal vesicles. By removing unessential voxel elements, this method provided direct visualization of those structures. For comparison, the targets of each patient were also obtained by contouring CT axial slices. Results: The method was successfully performed if the target structures were readily visualized and geometrically corresponded to those generated by contouring axial images. The targets in 9 of 10 patients were reliable representations of the CT-contoured volumes. One patient had 18 mm variation due to the lack of bladder opacification. Using VOIs to generate thin tissue DRRs, the time required for target and normal tissue localization was on the average less than 5 min. Conclusion: In CT simulation of the four-field irradiation technique for prostate carcinoma, thin-tissue DRRs allowed for efficient and accurate target localization without requiring individual axial image contouring. This method may facilitate positioning of the beam isocenter and provide reliable conformal radiotherapy

  3. Dosimetric Impact of Primary Planning Parameters in Dynamic Conformal Arc Technique for Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Yeon; Suh, Tae Suk [Dept. of Biomedical Engineering, The Catholic University of Korea, Seoul (Korea, Republic of); Kim, Si Yong [Dept. of Radiation Oncology, Mayo Clinic, Jacksonvile (United States); Lee, Jeong Woo [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of); Choi, Kyoung Sik [Dept. of Radiation Oncology, Anyang SAM Hospital, Anyang (Korea, Republic of)

    2011-04-15

    As one of the stereotactic body radiation therapy (SBRT) techniques, dynamic conformal arc therapy (DCAT) is commonly adopted to efficiently deliver conformal doses. However, as the DCAT uses numerous beams at individual control points, the dosimetric errors generated from each beam can be accumulated and manifested. In SBRT, therefore, due to the high fractional dose within a few fractions to moving target, the determination of the applied plan parameters can be critical and the evaluation of dosimetric impact of planning parameters would play an important role in DCAT planning process. In this study, we systematically evaluated the dosimetric influence caused by the variable grid size and the angular increment in DCAT for lung SBRT. Dose variations with different parameters were estimated for spherical and elongated tumors on an anthropomorphic phantom. The systematic analysis of the generated dose variation would guide to determine appropriate plan parameters and to estimate the dose errors in planning process in a clinical perspective of DCAT. It was found that two plan parameters, grid size and angular increment, in DCAT could cause non-negligible dose uncertainty. Coarse grid size led patients to get unnecessary overdose. Coarse angular increment could make significantly inaccurate prediction of OAR dose, resulting in either over- or under- estimation depending on the location of OAR relative to the isocenter.

  4. Hippocampal sparing radiotherapy for pediatric medulloblastoma: impact of treatment margins and treatment technique.

    Science.gov (United States)

    Brodin, N Patrik; Munck af Rosenschöld, Per; Blomstrand, Malin; Kiil-Berthlesen, Anne; Hollensen, Christian; Vogelius, Ivan R; Lannering, Birgitta; Bentzen, Søren M; Björk-Eriksson, Thomas

    2014-04-01

    We investigated how varying the treatment margin and applying hippocampal sparing and proton therapy impact the risk of neurocognitive impairment in pediatric medulloblastoma patients compared with current standard 3D conformal radiotherapy. We included 17 pediatric medulloblastoma patients to represent the variability in tumor location relative to the hippocampal region. Treatment plans were generated using 3D conformal radiotherapy, hippocampal sparing intensity-modulated radiotherapy, and spot-scanned proton therapy, using 3 different treatment margins for the conformal tumor boost. Neurocognitive impairment risk was estimated based on dose-response models from pediatric CNS malignancy survivors and compared among different margins and treatment techniques. Mean hippocampal dose and corresponding risk of cognitive impairment were decreased with decreasing treatment margins (P < .05). The largest risk reduction, however, was seen when applying hippocampal sparing proton therapy-the estimated risk of impaired task efficiency (95% confidence interval) was 92% (66%-98%), 81% (51%-95%), and 50% (30%-70%) for 3D conformal radiotherapy, intensity-modulated radiotherapy, and proton therapy, respectively, for the smallest boost margin and 98% (78%-100%), 90% (60%-98%), and 70% (39%-90%) if boosting the whole posterior fossa. Also, the distance between the closest point of the planning target volume and the center of the hippocampus can be used to predict mean hippocampal dose for a given treatment technique. We estimate a considerable clinical benefit of hippocampal sparing radiotherapy. In choosing treatment margins, the tradeoff between margin size and risk of neurocognitive impairment quantified here should be considered.

  5. Multilayer conformal applicator for microwave heating and brachytherapy treatment of superficial tissue disease.

    Science.gov (United States)

    Juang, T; Stauffer, P R; Neuman, D G; Schlorff, J L

    2006-11-01

    The purpose of this study was to construct and perform preliminary functionality evaluations of a multilayer conformal applicator with provisions for thermal monitoring, tight conformity and simultaneous microwave heating and brachytherapy treatment of large-area contoured surfaces. The multilayer conformal applicator consists of thermal monitoring catheters for fibre-optic monitoring of skin temperatures, a waterbolus, a PCB microwave antenna array, a dielectric spacer for brachytherapy considerations, brachytherapy catheters for delivering HDR radiation and an inflatable air bladder for improving conformity to contoured surfaces. The applicator also includes an elastic attachment structure to hold the applicator securely in place on the patient. The conformity of the applicator to irregular surfaces was evaluated through CT imaging of the applicator fitted onto a life-sized human torso phantom. The fluid flow dynamics of the waterbolus, which impact the effectiveness of temperature control, were evaluated with thermometry during a 19 degrees C step change temperature of the circulating water. CT imaging showed improved conformity to the torso phantom surface following the application of gentle inward pressure from inflating the outer air bladder. Only a small number of 1-5 mm sized air gaps separated the conformal applicator and tissue surface. Thermometry testing of the bolus fluid flow dynamics demonstrated temperature uniformity within +/-0.82 degrees C across a 19 x 34 x 0.6 cm area bolus and +/-0.85 degrees C across a large 42 x 32 x 0.6 cm area bolus. CT scans of the applicator confirmed that the applicator conforms well to complex body contours and should maintain good conformity and positional stability even when worn on a mobile patient. Thermometry testing of two different waterbolus geometries demonstrated that uniform circulation and temperature control can be maintained throughout large, complex bolus shapes.

  6. Conformal radiation therapy with or without intensity modulation in the treatment of localized prostate cancer

    International Nuclear Information System (INIS)

    Maingon, P.; Truc, G.; Bosset, M.; Peignaux, K.; Ammor, A.; Bolla, M.

    2005-01-01

    Conformal radiation therapy has now to be considered as a standard treatment of localized prostatic adenocarcinomas. Using conformational methods and intensity modulated radiation therapy requires a rigorous approach for their implementation in routine, focused on the reproducibility of the treatment, target volume definitions, dosimetry, quality control, setup positioning. In order to offer to the largest number of patients high-dose treatment, the clinicians must integrate as prognostic factors accurate definition of microscopic extension as well as the tolerance threshold of critical organs. High-dose delivery is expected to be most efficient in intermediary risks and locally advanced diseases. Intensity modulated radiation therapy is specifically dedicated to dose escalation. Perfect knowledge of classical constraints of conformal radiation therapy is required. Using such an approach in routine needs a learning curve including the physicists and a specific quality assurance program. (author)

  7. Biological Modeling Based Outcome Analysis (BMOA) in 3D Conformal Radiation Therapy (3DCRT) Treatments for Lung and Breast Cancers

    Science.gov (United States)

    Pyakuryal, Anil; Chen, Chiu-Hao; Dhungana, Sudarshan

    2010-03-01

    3DCRT treatments are the most commonly used techniques in the treatment of lung and breast cancers. The purpose of this study was to perform the BMOA of the 3DCRT plans designed for the treatment of breast and lung cancers utilizing HART program (Med. Phys. 36, p.2547(2009)). The BMOA parameters include normal tissue complication probability (NTCP), tumor control probability (TCP), and the complication-free tumor control probability (P+). The 3DCRT plans were designed for (i) the palliative treatment of 8 left lung cancer patients (CPs) at early stage (m=8), (ii) the curative treatment of 8 left lung CPs at stages II and III (k=8), and (iii) the curative treatment of 8 left breast CPs (n=8). The NTCPs were noticeably small (esophagus in lung CPs (k=8). Assessments of the TCPs and P+s also indicated good improvements in local tumor control in all plans. Homogeneous target coverage and improved dose conformality were the major advantages of such techniques in the treatment of breast cancer. These achievements support the efficacy of the 3DCRT techniques for the efficient treatment of various types of cancer.

  8. A study of the effects of internal organ motion on dose escalation in conformal prostate treatments

    International Nuclear Information System (INIS)

    Happersett, Laura; Mageras, Gig S.; Zelefsky, Michael J.; Burman, Chandra M.; Leibel, Steven A.; Chui Chen; Fuks, Zvi; Bull, Sarah; Ling, C. Clifton; Kutcher, Gerald J.

    2003-01-01

    Background and purpose: To assess the effect of internal organ motion on the dose distributions and biological indices for the target and non-target organs for three different conformal prostate treatment techniques. Materials and methods: We examined three types of treatment plans in 20 patients: (1) a six field plan, with a prescribed dose of 75.6 Gy; (2) the same six field plan to 72 Gy followed by a boost to 81 Gy; and (3) a five field plan with intensity modulated beams delivering 81 Gy. Treatment plans were designed using an initial CT data set (planning) and applied to three subsequent CT scans (treatment). The treatment CT contours were used to represent patient specific organ displacement; in addition, the dose distribution was convolved with a Gaussian distribution to model random setup error. Dose-volume histograms were calculated using an organ deformation model in which the movement between scans of individual points interior to the organs was tracked and the dose accumulated. The tumor control probability (TCP) for the prostate and proximal half of seminal vesicles (clinical target volume, CTV), normal tissue complication probability (NTCP) for the rectum and the percent volume of bladder wall receiving at least 75 Gy were calculated. Results: The patient averaged increase in the planned TCP between plan types 2 and 1 and types 3 and 1 was 9.8% (range 4.9-12.5%) for both, whereas the corresponding increases in treatment TCP were 9.0% (1.3-16%) and 8.1% (-1.3-13.8%). In all patients, plans 2 and 3 (81 Gy) exhibited equal or higher treatment TCP than plan 1 (75.6 Gy). The maximum treatment NTCP for rectum never exceeded the planning constraint and percent volume of bladder wall receiving at least 75 Gy was similar in the planning and treatment scans for all three plans. Conclusion: For plans that deliver a uniform prescribed dose to the planning target volume (PTV) (plan 1), current margins are adequate. In plans that further escalate the dose to part

  9. A study of the radiobiological modeling of the conformal radiation therapy in cancer treatment

    Science.gov (United States)

    Pyakuryal, Anil Prasad

    Cancer is one of the leading causes of mortalities in the world. The precise diagnosis of the disease helps the patients to select the appropriate modality of the treatments such as surgery, chemotherapy and radiation therapy. The physics of X-radiation and the advanced imaging technologies such as positron emission tomography (PET) and computed tomography (CT) plays an important role in the efficient diagnosis and therapeutic treatments in cancer. However, the accuracy of the measurements of the metabolic target volumes (MTVs) in the PET/CT dual-imaging modality is always limited. Similarly the external beam radiation therapy (XRT) such as 3D conformal radiotherapy (3DCRT) and intensity modulated radiation therapy (IMRT) is the most common modality in the radiotherapy treatment. These treatments are simulated and evaluated using the XRT plans and the standard methodologies in the commercial planning system. However, the normal organs are always susceptible to the radiation toxicity in these treatments due to lack of knowledge of the appropriate radiobiological models to estimate the clinical outcomes. We explored several methodologies to estimate MTVs by reviewing various techniques of the target volume delineation using the static phantoms in the PET scans. The review suggests that the more precise and practical method of delineating PET MTV should be an intermediate volume between the volume coverage for the standardized uptake value (SUV; 2.5) of glucose and the 50% (40%) threshold of the maximum SUV for the smaller (larger) volume delineations in the radiotherapy applications. Similarly various types of optimal XRT plans were designed using the CT and PET/CT scans for the treatment of various types of cancer patients. The qualities of these plans were assessed using the universal plan-indices. The dose-volume criteria were also examined in the targets and organs by analyzing the conventional dose-volume histograms (DVHs). The biological models such as tumor

  10. Comparison of normal tissue dose with three-dimensional conformal techniques for breast cancer irradiation including the internal mammary nodes

    NARCIS (Netherlands)

    van der Laan, Hans Paul; Dolsma, Willemtje; van t Veld, Aart; Bijl, HP; Langendijk, JA

    2005-01-01

    PURPOSE: To compare the Para Mixed technique for irradiation of the internal mammary nodes (IMN) with three commonly used strategies, by analyzing the dose to the heart and other organs at risk. METHODS AND MATERIALS: Four different three-dimensional conformal dose plans were created for 30 breast

  11. Techniques and methods to guarantee Bologna-conform higher education in GNSS

    Science.gov (United States)

    Mayer, M.

    2012-04-01

    The Bologna Declaration is aiming for student-centered, outcome-related, and competence-based teaching. In order to fulfill these demands, deep level learning techniques should be used to meet the needs of adult-compatible and self-determined learning. The presentation will summarize selected case studies carried out in the framework of the lecture course "Introduction into GNSS positioning" of the Geodetic Institute of the Karlsruhe Institute of Technology (Karlsruhe, Germany). The lecture course "Introduction into GNSS positioning" is a compulsory part of the Bachelor study course "Geodesy and Geoinformatics" and also a supplementary module of the Bachelor study course "Geophysics". Within the lecture course, basic knowledge and basic principles of Global Navigation Satellite Systems, like GPS, are imparted. The lecture course was migrated starting from a classically designed geodetic lecture course, which consisted of a well-adapted combination of teacher-centered classroom lectures and practical training (e.g., field exercises). The recent Bologna-conform blended learning concepts supports and motivates students to learn more sustainable using online and classroom learning methods. Therefore, an appropriate combination of - classroom lectures: Students and teacher give lectures - practical training: Students select topics individually - online learning: ILIAS (learning management system) is used as data, result, and communication platform. The framing didactical method is based on the so-called anchored instruction approach. Within this approach, an up-to-date scientific GNSS-related paper dealing with the large-scale geodetic project "Fehmarn Belt Fixed Link" is used as anchor. The students have to read the paper individually in the beginning of the semester. This enables them to realize a lot of not-known GNSS-related facts. Therefore, questions can be formulated. The lecture course deals with these questions, in order to answer them. At the end of the

  12. Conformal Radiotherapy in the Treatment of Advanced Juvenile Nasopharyngeal Angiofibroma With Intracranial Extension: An Institutional Experience

    International Nuclear Information System (INIS)

    Chakraborty, Santam; Ghoshal, Sushmita; Patil, Vijay Maruti; Oinam, Arun Singh; Sharma, Suresh C.

    2011-01-01

    Purpose: To describe the results of conformal radiotherapy in advanced juvenile nasopharyngeal angiofibroma in a tertiary care institution. Methods and Materials: Retrospective chart review was conducted for 8 patients treated with conformal radiotherapy between 2006 and 2009. The median follow-up was 17 months. All patients had Stage IIIB disease with intracranial extension. Radiotherapy was considered as treatment because patients were deemed inoperable owing to extensive intracranial/intraorbital extension or proximity to optic nerve. All but 1 patient were treated with intensity-modulated radiotherapy using seven coplanar fields. Median (range) dose prescribed was 39.6 (30-46) Gy. Actuarial analysis of local control and descriptive analysis of toxicity profile was conducted. Results: Despite the large and complex target volume (median planning target volume, 292 cm 3 ), intensity-modulated radiotherapy achieved conformal dose distributions (median van't Reit index, 0.66). Significant sparing of the surrounding organs at risk was obtained. No significant Grade 3/4 toxicities were experienced during or after treatment. Actual local control at 2 years was 87.5%. One patient died 1 month after radiotherapy secondary to massive epistaxis. The remaining 7 patients had progressive resolution of disease and were symptom-free at last follow-up. Persistent rhinitis was the only significant toxicity, seen in 1 patient. Conclusions: Conformal radiotherapy results in good local control with minimal acute and late side effects in juvenile nasopharyngeal angiofibromas, even in the presence of advanced disease.

  13. CT-image-based conformal brachytherapy of breast cancer. The significance of semi-3-D and 3-D treatment planning.

    Science.gov (United States)

    Polgár, C; Major, T; Somogyi, A; Takácsi-Nagy, Z; Mangel, L C; Forrai, G; Sulyok, Z; Fodor, J; Németh, G

    2000-03-01

    To compare the conventional 2-D, the simulator-guided semi-3-D and the recently developed CT-guided 3-D brachytherapy treatment planning in the interstitial radiotherapy of breast cancer. In 103 patients with T1-2, N0-1 breast cancer the tumor bed was clipped during breast conserving surgery. Fifty-two of them received boost brachytherapy after 46 to 50 Gy teletherapy and 51 patients were treated with brachytherapy alone via flexible implant tubes. Single, double and triple plane implant was used in 6, 89 and 8 cases, respectively. The dose of boost brachytherapy and sole brachytherapy prescribed to dose reference points was 3 times 4.75 Gy and 7 times 5.2 Gy, respectively. The positions of dose reference points varied according to the level (2-D, semi-3-D and 3-D) of treatment planning performed. The treatment planning was based on the 3-D reconstruction of the surgical clips, implant tubes and skin points. In all cases the implantations were planned with a semi-3-D technique aided by simulator. In 10 cases a recently developed CT-guided 3-D planning system was used. The semi-3-D and 3-D treatment plans were compared to hypothetical 2-D plans using dose-volume histograms and dose non-uniformity ratios. The values of mean central dose, mean skin dose, minimal clip dose, proportion of underdosaged clips and mean target surface dose were evaluated. The accuracy of tumor bed localization and the conformity of planning target volume and treated volume were also analyzed in each technique. With the help of conformal semi-3-D and 3-D brachytherapy planning we could define reference dose points, active source positions and dwell times individually. This technique decreased the mean skin dose with 22.2% and reduced the possibility of geographical miss. We could achieve the best conformity between the planning target volume and the treated volume with the CT-image based 3-D treatment planning, at the cost of worse dose homogeneity. The mean treated volume was reduced by 25

  14. The treatment of colorectal liver metastases with conformal radiation therapy and regional chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, John M; Lawrence, Theodore S; Walker, Suzette; Kessler, Marc L; Andrews, James C; Ensminger, William D

    1995-05-15

    Purpose: Whole-liver radiation, with or without chemotherapy, has been of modest benefit in the treatment of unresectable hepatic metastases from colorectal cancer. A Phase I/II study combining escalating doses of conformally planned radiation therapy (RT) with intraarterial hepatic (IAH) fluorodeoxyuridine (FdUrd) was performed. Methods and Materials: Twenty-two patients with unresectable hepatic metastases from colorectal cancer, 14 of whom had progressed after previous chemotherapy (2 with prior IAH FdUrd), were treated with concurrent IAH FdUrd (0.2 mg/kg/day) and conformal hepatic radiation therapy (1.5-1.65 Gy/fraction twice a day). The total dose of radiation given to the tumor (48-72.6 Gy) depended on the fraction of normal liver excluded from the high-dose volume. All patients were assessed for response, toxicity, hepatobiliary relapse, and survival. Median potential follow-up was 42 months. Results: Eleven of 22 patients demonstrated an objective response, with the remainder showing stable disease. Actuarial freedom from hepatic progression was 25% at 1 year. The most common acute toxicity was mild to moderate nausea and transient liver function test abnormalities. There were three patients with gastrointestinal bleeding (none requiring surgical intervention) after the completion of treatment. Overall median survival was 20 months. The presence of extrahepatic disease was associated with decreased survival (p < 0.01). Conclusions: Combined conformal radiation therapy and IAH FdUrd can produce an objective response in 50% of patients with hepatic metastases from colorectal cancer. However, response was not durable, and hepatic progression was frequent. Improvements in hepatic tumor control for patients with metastatic colorectal cancer may require higher doses of conformal radiation and/or improved radiosensitization. In an effort to increase radiosensitization, we have recently initiated a clinical trial combining IAH bromodeoxyuridine, a thymidine analog

  15. Three-dimensional (3D) real-time conformal brachytherapy - a novel solution for prostate cancer treatment Part I. Rationale and method

    International Nuclear Information System (INIS)

    Fijalkowski, M.; Bialas, B.; Maciejewski, B.; Bystrzycka, J.; Slosarek, K.

    2005-01-01

    Recently, the system for conformal real-time high-dose-rate brachytherapy has been developed and dedicated in general for the treatment of prostate cancer. The aim of this paper is to present the 3D-conformal real-time brachytherapy technique introduced to clinical practice at the Institute of Oncology in Gliwice. Equipment and technique of 3D-conformal real time brachytherapy (3D-CBRT) is presented in detail and compared with conventional high-dose-rate brachytherapy. Step-by-step procedures of treatment planning are described, including own modifications. The 3D-CBRT offers the following advantages: (1) on-line continuous visualization of the prostate and acquisition of the series of NS images during the entire procedure of planning and treatment; (2) high precision of definition and contouring the target volume and the healthy organs at risk (urethra, rectum, bladder) based on 3D transrectal continuous ultrasound images; (3) interactive on-line dose optimization with real-time corrections of the dose-volume histograms (DVHs) till optimal dose distribution is achieved; (4) possibility to overcome internal prostate motion and set-up inaccuracies by stable positioning of the prostate with needles fixed to the template; (5) significant shortening of overall treatment time; (6) cost reduction - the treatment can be provided as an outpatient procedure. The 3D- real time CBRT can be advertised as an ideal conformal boost dose technique integrated or interdigitated with pelvic conformal external beam radiotherapy or as a monotherapy for prostate cancer. (author)

  16. Bladder radiotherapy treatment: A retrospective comparison of 3-dimensional conformal radiotherapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy plans

    Energy Technology Data Exchange (ETDEWEB)

    Pasciuti, Katia, E-mail: k.pasciuti@virgilio.it [Department of Radiotherapy Physics, Royal Free Hospital, London (United Kingdom); Kuthpady, Shrinivas [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom); Anderson, Anne; Best, Bronagh [Department of Radiotherapy Physics, Royal Free Hospital, London (United Kingdom); Waqar, Saleem; Chowdhury, Subhra [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom)

    2017-04-01

    To examine tumor's and organ's response when different radiotherapy plan techniques are used. Ten patients with confirmed bladder tumors were first treated using 3-dimensional conformal radiotherapy (3DCRT) and subsequently the original plans were re-optimized using the intensity-modulated radiation treatment (IMRT) and volumetric-modulated arc therapy (VMAT)-techniques. Targets coverage in terms of conformity and homogeneity index, TCP, and organs' dose limits, including integral dose analysis were evaluated. In addition, MUs and treatment delivery times were compared. Better minimum target coverage (1.3%) was observed in VMAT plans when compared to 3DCRT and IMRT ones confirmed by a statistically significant conformity index (CI) results. Large differences were observed among techniques in integral dose results of the femoral heads. Even if no statistically significant differences were reported in rectum and tissue, a large amount of energy deposition was observed in 3DCRT plans. In any case, VMAT plans provided better organs and tissue sparing confirmed also by the normal tissue complication probability (NTCP) analysis as well as a better tumor control probability (TCP) result. Our analysis showed better overall results in planning using VMAT techniques. Furthermore, a total time reduction in treatment observed among techniques including gantry and collimator rotation could encourage using the more recent one, reducing target movements and patient discomfort.

  17. A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapy

    International Nuclear Information System (INIS)

    Nutting, Christopher M.; Bedford, James L.; Cosgrove, Vivian P.; Tait, Diana M.; Dearnaley, David P.; Webb, Steve

    2001-01-01

    Background and purpose: To investigate the potential of intensity-modulated radiotherapy (IMRT) to reduce lung irradiation in the treatment of oesophageal carcinoma with radical radiotherapy. Materials and methods: A treatment planning study was performed to compare two-phase conformal radiotherapy (CFRT) with IMRT in five patients. The CFRT plans consisted of anterior, posterior and bilateral posterior oblique fields, while the IMRT plans consisted of either nine equispaced fields (9F), or four fields (4F) with orientations equal to the CFRT plans. IMRT plans with seven, five or three equispaced fields were also investigated in one patient. Treatment plans were compared using dose-volume histograms and normal tissue complication probabilities. Results: The 9F IMRT plan was unable to improve on the homogeneity of dose to the planning target volume (PTV), compared with the CFRT plan (dose range, 16.9±4.5 (1 SD) vs. 12.4±3.9%; P=0.06). Similarly, the 9F IMRT plan was unable to reduce the mean lung dose (11.7±3.2 vs. 11.0±2.9 Gy; P=0.2). Similar results were obtained for seven, five and three equispaced fields in the single patient studied. The 4F IMRT plan provided comparable PTV dose homogeneity with the CFRT plan (11.8±3.3 vs. 12.4±3.9%; P=0.6), with reduced mean lung dose (9.5±2.3 vs 11.0±2.9 Gy; P=0.001). Conclusions: IMRT using nine equispaced fields provided no improvement over CFRT. This was because the larger number of fields in the IMRT plan distributed a low dose over the entire lung. In contrast, IMRT using four fields equal to the CFRT fields offered an improvement in lung sparing. Thus, IMRT with a few carefully chosen field directions may lead to a modest reduction in pneumonitis, or allow tumour dose escalation within the currently accepted lung toxicity

  18. Treatment accuracy of hypofractionated spine and other highly conformal IMRT treatments

    International Nuclear Information System (INIS)

    Sutherland, B.; Hanlon, P.; Charles, P.

    2011-01-01

    Full text: Spinal cord metastases pose difficult challenges for radiation treatment due to tight dose constraints and a concave PTY. This project aimed to thoroughly test the treatment accuracy of the Eclipse Treatment Planning System (TPS) for highly modulated IMRT treatments, in particular of the thoracic spine, using an Elekta Synergy Linear Accelerator. The increased understanding obtained through different quality assurance techniques allowed recommendations to be made for treatment site commissioning with improved accuracy at the Princess Alexandra Hospital (PAH). Three thoracic spine IMRT plans at the PAH were used for data collection. Complex phantom models were built using CT data, and fields simulated using Monte Carlo modelling. The simulated dose distributions were compared with the TPS using gamma analysis and DYH comparison. High resolution QA was done for all fields using the MatriXX ion chamber array, MapCHECK2 diode array shifted, and the EPlD to determine a procedure for commissioning new treatment sites. Basic spine simulations found the TPS overestimated absorbed dose to bone, however within spinal cord there was good agreement. High resolution QA found the average gamma pass rate of the fields to be 99.1 % for MatriXX, 96.5% for MapCHECK2 shifted and 97.7% for EPlD. Preliminary results indicate agreement between the TPS and delivered dose distributions higher than previously believed for the investigated IMRT plans. The poor resolution of the MatriXX, and normalisation issues with MapCHECK2 leads to probable recommendation of EPlD for future IMRT commissioning due to the high resolution and minimal setup required.

  19. Cost-benefit analysis of 3D conformal radiation therapy. Treatment of prostate cancer as a model

    International Nuclear Information System (INIS)

    Cho, K.H.; Khan, F.M.; Levitt, S.H.

    1999-01-01

    Three-dimensional conformal radiation therapy (3D-CRT) is a promising new treatment technique based on the principle that improved precision in both tumor definition and dose delivery will enhance outcomes by maximizing dose to the tumor area while minimizing dose to normal tissue. Using a cost-benefit analysis, in terms of outcomes, we first examined the overall risks and benefits of 3D-CRT. We then used the treatment of prostate cancer as a model to compare actual clinical outcomes reported between 3D-CRT and standard radiation therapy (SRT). Our analysis shows that application of 3D-CRT to the clinical setting remains difficult because of the continual difficulties of target definition, and that dose escalation cannot yet be justified on the basis of the lack of benefit found, and suggested increased late toxicity, in most of the dose escalation series compared with SRT. (orig.)

  20. High dose rate endobronchial brachytherapy - treatment technique

    International Nuclear Information System (INIS)

    Carvalho, Heloisa de Andrade; Aisen, Salim; Haddad, Cecilia Maria Kalil; Nadalin, Wladimir; Pedreira Junior, Wilson Leite; Chavantes, Maria Cristina

    1998-01-01

    High dose rate endobronchial brachytherapy is efficient in symptom relief due to obstructive endobronchial malignancies. However, it's role in survival improvement for patients with lung cancer is not yet established. The use of this treatment in increasing, specially in the developing countries. The purpose of this paper is to present the treatment technique used in the Radiotherapy Department of the Hospital da Clinicas, University of Sao Paulo, based on an experience of 60 cases treated with 180 procedures. Some practical suggestions and rules adopted in the Department are described. The severe complications rate is 6.7%, demonstrating an adequate patient selection associated with the technique utilized. (author)

  1. Dosimetric comparison of proton and photon three-dimensional, conformal, external beam accelerated partial breast irradiation techniques

    International Nuclear Information System (INIS)

    Kozak, Kevin R.; Katz, Angela; Adams, Judith C.; Crowley, Elizabeth M.; Nyamwanda, Jacqueline A.C.; Feng, Jennifer K.C.; Doppke, Karen P.; DeLaney, Thomas F.; Taghian, Alphonse G.

    2006-01-01

    Purpose: To compare the dosimetry of proton and photon-electron three-dimensional, conformal, external beam accelerated partial breast irradiation (3D-CPBI). Methods and Materials: Twenty-four patients with fully excised, Stage I breast cancer treated with adjuvant proton 3D-CPBI had treatment plans generated using the mixed-modality, photon-electron 3D-CPBI technique. To facilitate dosimetric comparisons, planning target volumes (PTVs; lumpectomy site plus 1.5-2.0 cm margin) and prescribed dose (32 Gy) were held constant. Plans were optimized for PTV coverage and normal tissue sparing. Results: Proton and mixed-modality plans both provided acceptable PTV coverage with 95% of the PTV receiving 90% of the prescribed dose in all cases. Both techniques also provided excellent dose homogeneity with a dose maximum exceeding 110% of the prescribed dose in only one case. Proton 3D-CPBI reduced the volume of nontarget breast tissue receiving 50% of the prescribed dose by an average of 36%. Statistically significant reductions in the volume of total ipsilateral breast receiving 100%, 75%, 50%, and 25% of the prescribed dose were also observed. The use of protons resulted in small, but statistically significant, reductions in the radiation dose delivered to 5%, 10%, and 20% of ipsilateral and contralateral lung and heart. The nontarget breast tissue dosimetric advantages of proton 3D-CPBI were not dependent on tumor location, breast size, PTV size, or the ratio of PTV to breast volume. Conclusions: Compared to photon-electron 3D-CPBI, proton 3D-CPBI significantly reduces the volume of irradiated nontarget breast tissue. Both approaches to accelerated partial breast irradiation offer exceptional lung and heart sparing

  2. CT-image based conformal brachytherapy of breast cancer. The significance of semi-3-D and 3-D treatment planning

    International Nuclear Information System (INIS)

    Polgar, C.; Major, T.; Somogyi, A.; Takacsi-Nagy, Z.; Mangel, L.C.; Fodor, J.; Nemeth, G.; Forrai, G.; Sulyok, Z.

    2000-01-01

    In 103 patients with T1-2, N0-1 breast cancer the tumor bed was clipped during breast conserving surgery. Fifty-two of them received boost brachytherapy after 46 to 50 Gy teletherapy and 51 patients were treated with brachytherapy alone via flexible implant tubes. Single double and triple plane implant was used in 6,89 and 8 cases, respectively. The dose of boost brachytherapy and sole brachytherapy prescribed to dose reference points was 3 times 4.75 Gy and 7 times 5.2 Gy, respectively. The positions of dose reference points varied according to the level (2-D, semi-3-D and 3-D) of treatment planning performed. The treatment planning was based on the 3-D reconstruction of the surgical clips, implant tubes and skin points. In all cases the implantations were planned with a semi-3-D technique aided by simulator. In 10 cases a recently developed CT-guided 3-D planning system was used. The semi-3D and 3-D treatment plans were compared to hypothetical 2-D plans using dose-volume histograms and dose non-uniformity ratios. The values of mean central dose, mean skin dose, minimal clip dose, proportion of underdosaged clips and mean target surface dose were evaluated. The accuracy of tumor bed localization and the conformity of planning target volume and treated volume were also analyzed in each technique. Results: With the help of conformal semi-3D and 3D brachytherapy planning we could define reference dose points, active source positions and dwell times individually. This technique decreased the mean skin dose with 22.2% and reduced the possibility of geographical miss. We could achieve the best conformity between the planning target volume and the treated volume with the CT-image based 3-D treatment planning, at the cost of worse dose homogeneity. The mean treated volume was reduced by 25.1% with semi-3-D planning, however, its was increased by 16.2% with 3-D planning, compared to the 2-D planning. (orig.) [de

  3. Chronic rectal bleeding after high dose conformal treatment of prostate cancer warrants modification of existing morbidity scales

    International Nuclear Information System (INIS)

    Hanlon, A.L.; Schulthiess, T.E.; Hunt, M.A.; Movsas, B.; Peter, R.; Hanks, G.E.

    1996-01-01

    Purpose: Serious late morbidity (Grade (3(4))) from the conformal treatment of prostate cancer has been reported in <1% to 6% of patients. This study demonstrates that the reported frequency of Grade (3(4)) complications varies by the morbidity scale selected and that no existing morbidity scale adequately represents chronic rectal bleeding, which is our most frequent persisting late sequela of high dose conformal treatment. Materials and Methods: Between (5(89)) and (12(93)), 352 patients with T1-3 NXM0 prostate cancers were treated with our 4-field conformal technique without special rectal blocking. This technique includes a 1 cm margin from the CTV to the PTV in all directions. The median follow-up for these patients was 38 mos (4 to 78), and the median ICRU reporting point dose was 74 Gy (63 to 81). Patients are followed at six month intervals, and no patient is lost to follow-up. Three morbidity scales are assessed, the RTOG, the late effects group (LENT), and our modification of the LENT (FC-LENT). This modification registers chronic rectal bleeding requiring more than two coagulations as a grade 3 event. Estimates for Grade (3(4)) late GI complication rates were determined using Kaplan-Meier methodology. Differences in morbidity rates were evaluated using the log-rank test and differences in time to latency of complications were evaluated using the nonparametric Wilcoxon test. The duration of severe symptoms with chronic rectal bleeding is measured from the first to the last transrectal coagulation. Results: Sixteen patients developed Grade (3(4)) complications by one of the three morbidity scales. Two patients required surgery (colostomy, sigmoid resection), 5 required a transfusion, and 9 required more than two coagulations. The median latency to the third coagulation (plus or minus transfusions) was 24 mos (17 to 40). The median duration of bleeding between the first and last coagulation was 6 mos (3 to 25), illustrating the chronicity of this problem

  4. Conformable liquid metal printed epidermal electronics for smart physiological monitoring and simulation treatment

    Science.gov (United States)

    Wang, Xuelin; Zhang, Yuxin; Guo, Rui; Wang, Hongzhang; Yuan, Bo; Liu, Jing

    2018-03-01

    Conformable epidermal printed electronics enabled from gallium-based liquid metals (LMs), highly conductive and low-melting-point alloys, are proposed as the core to achieving immediate contact between skin surface and electrodes, which can avoid the skin deformation often caused by conventional rigid electrodes. When measuring signals, LMs can eliminate resonance problems with shorter time to reach steady state than Pt and gelled Pt electrodes. By comparing the contact resistance under different working conditions, it is demonstrated that both ex vivo and in vivo LM electrode-skin models have the virtues of direct and immediate contact with skin surface without the deformation encountered with conventional rigid electrodes. In addition, electrocardio electrodes composed of conformable LM printed epidermal electronics are adopted as smart devices to monitor electrocardiogram signals of rabbits. Furthermore, simulation treatment for smart defibrillation offers a feasible way to demonstrate the effect of liquid metal electrodes (LMEs) on the human body with less energy loss. The remarkable features of soft epidermal LMEs such as high conformability, good conductivity, better signal stability, and fine biocompatibility represent a critical step towards accurate medical monitoring and future smart treatments.

  5. TH-EF-204-04: Experience of IMRT and Other Conformal Techniques in Russia

    International Nuclear Information System (INIS)

    Krylova, T.

    2016-01-01

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  6. TH-EF-204-04: Experience of IMRT and Other Conformal Techniques in Russia

    Energy Technology Data Exchange (ETDEWEB)

    Krylova, T. [Russian Research Cancer Center (Russian Federation)

    2016-06-15

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  7. Relation between anchorings of liquid crystals and conformation changes in aligning agents by the Langmuir-Blodgett film technique investigation

    International Nuclear Information System (INIS)

    Zhu, Y.; Lu, Z.; Wei, Y.

    1995-01-01

    The anchoring direction of liquid crystals on a solid substrate surface depends upon many parameters characterizing the liquid-crystal--substrate interface, a variation of which may change this anchoring direction leading to the so-called anchoring transition. Here, based on the Langmuir-Blodgett film technique, we present two model systems to study the relation between anchoring directions and the conformation changes in aligning agents. A double-armed crown ether liquid crystal and a side chain polymer liquid crystal at an air-water interface both show phase transitions, accompanied by conformation changes. However, when the monolayers in different phases were transferred onto solid substrates to orient liquid crystals, we found that for the crown ether material the conformation change can alter the anchoring of liquid crystals between homeotropic and homogeneous alignments, while for the polymer liquid crystal, despite the conformation changes, the liquid crystals can only be aligned homeotropically. The involved mechanisms were briefly discussed in terms of the Landau-type phenomenological theory

  8. Conformal radiotherapy in the adjuvant treatment of gastric cancer: Review of 82 cases

    International Nuclear Information System (INIS)

    Kassam, Zahra; Lockwood, Gina; O'Brien, Catherine; Brierley, James; Swallow, Carol; Oza, Amit; Siu, Lillian; Knox, Jennifer J.; Wong, Rebecca; Cummings, Bernard; Kim, John; Moore, Malcolm; Ringash, Jolie

    2006-01-01

    Background: The Intergroup 0116 study showed a survival benefit with adjuvant chemoradiotherapy (CRT) for resected gastric cancer. We report our experience using conformal radiotherapy (RT). Methods and Materials: Eighty-two patients with resected gastric or gastroesophageal junction (GEJ) adenocarcinoma, Stage IB to IV (M0), were treated with 45 Gy in 25 fractions using a 5-field conformal technique. Chemotherapy was in accordance with the Intergroup 0116 study, or infusional 5-fluorouracil and cisplatin in a phase I/II trial. Results: Mean age was 56.4 years. Median follow-up was 22.8 months. Grade 3 or greater acute toxicity (National Cancer Institute Common Terminology Criteria of Adverse Events, version 3.0) was noted in 57% of patients (upper gastrointestinal tract 34%, hematologic 33%). One patient died of neutropenic sepsis. Radiation Therapy Oncology Group Grade 3 late toxicity included esophageal strictures (3 patients) and small bowel obstruction (1 patient). Full course CRT was completed by 67% of patients. Of 26 patients who relapsed, 20 died. Site of first relapse was available on 23 patients: 8 locoregional and distant, 4 locoregional alone, 11 distant alone. Overall and relapse-free survival were 69% and 54% at 3 years. Conclusion: Adjuvant CRT for gastric cancer, even with conformal RT, is associated with significant toxicity. Survival was comparable to that reported in the Intergroup 0116 study

  9. Three dimensional conformal radiotherapy for synchronous bilateral breast irradiation using a mono iso-center technique

    Science.gov (United States)

    Mani, Karthick Raj; Basu, Saumen; Bhuiyan, Md Anisuzzaman; Ahmed, Sharif; Sumon, Mostafa Aziz; Haque, Kh Anamul; Sengupta, Ashim Kumar; Un Nabi, Md Rashid; Das, K. J. Maria

    2017-06-01

    Objective: The purpose of this study is to demonstrate the synchronous bilateral breast irradiation radiotherapy technique using a single isocenter. Materials and Methods: Six patients of synchronous bilateral breast were treated with single isocenter technique from February 2011 to June 2016. All the patients underwent a CT-simulation using appropriate positioning device. Target volumes and critical structures like heart, lung, esophagus, thyroid, etc., were delineated slice by slice in the CT data. An isocenter was placed above the sternum on the skin and both medial tangential and lateral tangential of the breast / chest wall were created using asymmetrical jaws to avoid the beam divergence through the lung and heart. The field weighting were adjusted manually to obtain a homogenous dose distribution. The planning objectives were to deliver uniform doses around the target and keep the doses to the organ at risk within the permissible limit. The beam energy of 6 MV or combination of 6 MV and 15 MV photons were used in the tangential fields according to the tangential separation. Boluses were used for all the mastectomy patients to increase the doses on the chest wall. In addition to that enhanced dynamic wedge and field in field technique were also used to obtain a homogenous distribution around the target volume and reduce the hot spots. The isocenter was just kept on the skin, such that the beam junctions will be overlapped only on the air just above the sternum. Acute toxicity during the treatment and late toxicity were recorded during the patient's follow-up. Results: During the radiotherapy treatment follow-up there were no acute skin reactions in the field junctions, but one patient had grade 1 esophagitis and two patients had grade 2 skin reactions in the chest wall. With a median follow-up of 38.5 months (range: 8 - 49 months), no patients had a local recurrence, but one patients with triple negative disease had a distant metastases in brain and died

  10. Investigation of conformal and intensity-modulated radiation therapy techniques to determine the absorbed fetal dose in pregnant patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Öğretici, Akın, E-mail: akinogretici@gmail.com; Akbaş, Uğur; Köksal, Canan; Bilge, Hatice

    2016-07-01

    The aim of this research was to investigate the fetal doses of pregnant patients undergoing conformal radiotherapy or intensity-modulated radiation therapy (IMRT) for breast cancers. An Alderson Rando phantom was chosen to simulate a pregnant patient with breast cancer who is receiving radiation therapy. This phantom was irradiated using the Varian Clinac DBX 600 system (Varian Medical System, Palo Alto, CA) linear accelerator, according to the standard treatment plans of both three-dimensional conformal radiation therapy (3-D CRT) and IMRT techniques. Thermoluminescent dosimeters were used to measure the irradiated phantom's virtually designated uterus area. Thermoluminescent dosimeter measurements (in the phantom) revealed that the mean cumulative fetal dose for 3-D CRT is 1.39 cGy and for IMRT it is 8.48 cGy, for a pregnant breast cancer woman who received radiation treatment of 50 Gy. The fetal dose was confirmed to increase by 70% for 3-D CRT and 40% for IMRT, if it is closer to the irradiated field by 5 cm. The mean fetal dose from 3-D CRT is 1.39 cGy and IMRT is 8.48 cGy, consistent with theoretic calculations. The IMRT technique causes the fetal dose to be 5 times more than that of 3-D CRT. Theoretic knowledge concerning the increase in the peripheral doses as the measurements approached the beam was also practically proven.

  11. SU-F-T-112: Long-Term Follow-Up of NSCLC Patients Treated with Lung SBRT Using the Modified Conformal Arc (MDCA) Planning Technique

    Energy Technology Data Exchange (ETDEWEB)

    Ku, E; Desai, A [Frank H Netter, MD, School of Medicine, North Haven, CT (United States); Fang, D; Lawrence, C; Iannuzzi, C; Shi, C [St. Vincent’s Medical Center, Bridgeport, CT (United States)

    2016-06-15

    Purpose: To assess long-term toxicity and primary tumor changes for Stage I/II non-small cell lung carcinoma (NSCLC) patients after treatment with lung SBRT using the modified dynamic conformal arc (MDCA) planning technique. Methods: Clinical and radiograph data from electronic health records of 15 NSCLC patients treated with lung SBRT utilizing the MDCA technique between October 2011 and July 2014 were retrospectively reviewed. MDCA uses a coplanar beam arrangement, patient body center for the beam isocenter, and six partial rotation conformal arcs to target the tumor. Radiation Therapy Oncology Group (RTOG) guidelines for treatment parameters were followed. Most patients received 5 radiation fractions (Range: 3 to 7 fractions) with 48 hours between each fraction. Median total dose was 60 Gy (range: 45 to 70 Gy). Results: Median follow-up was 18 months (range: 6–51 months). Median age was 72.5 years (range: 48–90 years). Post-treatment findings included fatigue (n = 5) and chronic chest wall pain (n=1). Seven patients reported respiratory symptoms, which included: cough (n = 4), dyspnea (n = 5), and hemoptysis (n = 1). No patients deaths or grade ≥4 toxicity were recorded. Radiographic scarring was seen on computed tomography (CT) imaging in 6 patients. Local control rate was 93.3% (n = 14) and 1 patient had local recurrence. Conclusion: Our results were very similar to RTOG 0236 findings reported by Timmerman et al. – our local control rate was 93.3% compared to their 3-year primary tumor control rate of 97.6%. Toxicity rates were also similar – RTOG 0236 constitutional symptoms and pulmonary/upper respiratory symptoms rates were 36.4% and 60.0%, respectively, while ours were 33.3% and 46.7%, respectively. We were limited by a small sample size and relatively short follow-up but our findings support the use of the MDCA technique for lung SBRT treatment of Stage I/II NSCLC.

  12. Development of radioactive waste treatment technique

    International Nuclear Information System (INIS)

    Kikuchi, Makoto; Amamiya, Shigeru; Yusa, Hideo.

    1984-01-01

    The techniques of radioactive waste treatment are generally reviewed, placing emphasis on volume reduction and solidification techniques. After a brief description on the general process of radioactive waste treatment, some special technologies being developed by Hitachi Ltd. are explained. From the viewpoints of the volume reduction, long term management and final disposal of wastes, the pelletization of dried waste and the solidification with inorganic substances are considered. One of the features of the pelletization system is to treat various kinds of wastes such as concentrated liquid wastes and used resins by the same system. The flow diagram of the system and its special features are shown. The volume reduction achieved by this system as compared to the conventional method is about 1/7. The first commercial plant for the treatment of concentrated liquid waste is scheduled to begin operation in June, 1984. As for the solidification technique for waste disposal, the use of cement glass is considered. The solidification system being developed is shortly described. (Aoki, K.)

  13. Development of novel conformity indices for quantitative comparison of radiation treatment plans

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Min; Park, So Yeon; Wu, Hong Gyun; Ye, Sung Joon; Kim, Jin Ho; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2013-11-15

    The conformity index (CI) is an indicator to assess the degree of congruence between a shape of reference isodose volume (VRI) and a shape of the target volume (TV). Two concepts are included in the CI, which are the target coverage and the degree of normal tissue sparing in the proximity of the target. Even though this could be verified by a manual review of dose distributions calculated on patient CT images slice by slice, detailed comparisons among several treatment plans would be inconvenient. The conformity could be also verified by reviewing dose-volume histograms (DVHs) of each structure calculated by treatment planning system (TPS). The prerequisite for this is the contouring of not only organs at risk (OARs) but also every structure in a patient body, which is not practical in the clinic. Therefore, a value possible to quantify the conformity was needed, and various studies on CI have been performed. Various CIs have been developed since 1993. Most of them are based on the calculation of the volumes except for the CI suggested by Wu et al. and Cheung et al. which were based on the distance. The aim of this study was to develop new CIs based on the calculations of angles and distances. The CI angle based on the analysis of the angle differences as well as the CIabs{sub d}istance and the CIdistance based on the analysis of the distances between the TV and the VRI were developed and evaluated in this study. The CI distance with Sornatomedins better performances than the CIangle and the CIabs{sub d}istance as well as the conventional CIs in various situations.

  14. Predicting treatment related imaging changes (TRICs) after radiosurgery for brain metastases using treatment dose and conformality metrics.

    Science.gov (United States)

    Taylor, B Frazier; Knisely, Jonathan P; Qian, Jack M; Yu, James B; Chiang, Veronica L

    2016-01-01

    Treatment-related imaging changes (TRICs) after stereotactic radiosurgery (SRS) involves the benign transient enlargement of radiographic lesions after treatment. Identifying the radiation dose volumes and conformality metrics associated with TRICs for different post-treatment periods would be helpful and improve clinical decision making. 367 metastases in 113 patients were treated using Gamma Knife SRS between 1/1/2007-12/31/2009. Each metastasis was measured at each imaging follow-up to detect TRICs (defined as ≥ 20% increase in volume). Fluctuations in small volume lesions (less than 108 mm 3 ) were ignored given widely variable conformity indices (CI) for small volumes. The Karolinska Adverse Radiation Effect (KARE) factor, Paddick's CI, Shaw's CI, tumor volume (TV), 10 Gy (V10) and 12 Gy (V12) volumes, and prescription isodose volume (PIV) were calculated. From 0-6 months, all measures correlated with the incidence of TRICs (p<.001), except KARE, which was inversely correlated. During the 6-12 month period all measures except KARE were still correlated. Beyond 12 months, no correlation was found between any of the measures and the development of TRICs. All metrics except KARE were associated with TRICs from 0-12 months only. Additional patient and treatment factors may become dominant at greater times after SRS.

  15. Conventional (2D) Versus Conformal (3D) Techniques in Radiotherapy for Malignant Pediatric Tumors: Dosimetric Perspectives

    International Nuclear Information System (INIS)

    Ahmad, N.; Attia, G.; Radwan, A.; El-Badawy, S.; El-Ghoneimy, E.

    2009-01-01

    Objectives: In pediatric radiotherapy, the enhanced radiosensitivity of the developing tissues combined with the high overall survival, raise the possibility of late complications. The present study aims at comparing two dimensional (2D) and three dimensional (3D) planning regarding dose homogeneity within target volume and dose to organs at risk (OARs) to demonstrate the efficacy of 3D in decreasing dose to normal tissue. Material and Methods: Thirty pediatric patients (18 years or less) with different pediatric tumors were planned using 2D and 3D plans. All were CT scanned after proper positioning and immobilization. Structures were contoured; including the planning target volume (PTV) and organs at risk (OARs). Conformal beams were designed and dose distribution analysis was edited to provide the best dose coverage to the PTV while sparing OARs using dose volume histograms (DVHs) of outlined structures. For the same PTVs conventional plans were created using the conventional simulator data (2-4 coplanar fields). Conventional and 3D plans coverage and distribution were compared using the term of V95% (volume of PTV receiving 95% of the prescribed dose), V107% (volume of PTV receiving 107% of the prescribed dose), and conformity index (CI) (volume receiving 90% of the prescribed dose/PTV). Doses received by OARs were compared in terms of mean dose. In children treated for brain lesions, OAR volume received 90% of the dose (V 90%) and OAR score were calculated. Results: The PTV coverage showed no statistical difference between 2D and 3D radiotherapy in terms of V95% or V107%. However, there was more conformity in 3D planning with CI 1.43 rather than conventional planning with CI 1.86 (p-value <0.001). Regarding OARs, 3D planning shows large gain in healthy tissue sparing. There was no statistical difference in mean dose received by each OAR. However, for brain cases, brain stem mean dose and brain V 90% showed better sparing in 3D planning (brain stem mean dose was

  16. Use of the neutron diffraction - H/D exchange technique to determine the conformational dynamics of trypsin

    International Nuclear Information System (INIS)

    Kossiakoff, A.A.

    1982-01-01

    Reported here are studies analyzing the extent and nature of the inherent conformational fluctuations in trypsin by neutron diffraction - hydrogen exchange techniques. The pattern of exchange investigates systematic relationships between exchangeable sites and the structural and chemical properties of the molecule. Our findings that pH 7, 20 0 and 1 year of soaking all sites of trypsin are fully exchanged except those which are especially well protected by the structure. Essentially all the sites in which the peptide hydrogens are bonded directly to water molecules - either in the bulk solvent regions or in interior clusters - are fully exchanged. 41 references, 10 figures

  17. Monaldi's technique for treatment of pulmonary abscesses

    International Nuclear Information System (INIS)

    Fuentes Valdes, Edelberto

    2010-01-01

    The pulmonary abscesses are usually treated with antibiotics and postural drainage. However, some patients don't improve with conservative measures or have contraindications for conventional surgical treatment. The aim of present paper was the presentation of three cases underwent percutaneous drainage of pulmonary abscesses. The technique used for tube insertion, complications and postoperative course of patients were described. In such cases operation was successful without mortality and with a bronchopleural cutaneous fistula like the only complication requiring a further intervention (pneumonectomy). The percutaneous drainage of pulmonary abscesses was safe and effective in our patients. (author)

  18. Impact of inter- and intrafraction deviations and residual set-up errors on PTV margins. Different alignment techniques in 3D conformal prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Langsenlehner, T.; Doeller, C.; Winkler, P.; Kapp, K.S.; Galle, G.

    2013-01-01

    The aim of this work was to analyze interfraction and intrafraction deviations and residual set-up errors (RSE) after online repositioning to determine PTV margins for 3 different alignment techniques in prostate cancer radiotherapy. The present prospective study included 44 prostate cancer patients with implanted fiducials treated with three-dimensional (3D) conformal radiotherapy. Daily localization was based on skin marks followed by marker detection using kilovoltage (kV) imaging and subsequent patient repositioning. Additionally, in-treatment megavoltage (MV) images were obtained for each treatment field. In an off-line analysis of 7,273 images, interfraction prostate motion, RSE after marker-based prostate localization, prostate position during each treatment session, and the effect of treatment time on intrafraction deviations were analyzed to evaluate PTV margins. Margins accounting for interfraction deviation, RSE and intrafraction motion were 14.1, 12.9, and 15.1 mm in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) direction for skin mark alignment and 9.6, 8.7, and 2.6 mm for bony structure alignment, respectively. Alignment to implanted markers required margins of 4.6, 2.8, and 2.5 mm. As margins to account for intrafraction motion increased with treatment prolongation PTV margins could be reduced to 3.9, 2.6, and 2.4 mm if treatment time was ≤ 4 min. With daily online correction and repositioning based on implanted fiducials, a significant reduction of PTV margins can be achieved. The use of an optimized workflow with faster treatment techniques such as volumetric modulated arc techniques (VMAT) could allow for a further decrease. (orig.)

  19. Comparison between conventional and three-dimensional conformal treatment planning for radiotherapy of cerebral tumors

    International Nuclear Information System (INIS)

    Caudrelier, J.M.; Auliard, A.; Sarrazin, T.; Gibon, D.; Coche-Dequeant, B.; Castelain, B.

    2001-01-01

    Comparison between conventional and three-dimensional conformal treatment planning for radiotherapy of cerebral tumors. Purpose. - We prospectively compared a conventional treatment planning (PT2D) and 3-dimensional conformal treatment planning (PT3D) for radiotherapy of cerebral tumours. Patients and methods.- Patients treated between 1/10/98 and 1/4/99 by irradiation for cerebral tumours were analysed. For each case, we planned PT2D using conventional orthogonal x-ray films, and afterward, PT3D using CT scan. Gross tumor volume, planning target volume and normal tissue volumes were defined. Dose was prescribed according to report 50 of the International Commission on Radiation Units and Measurements (ICRU). We compared surfaces of sagittal view targets defined on PT2D and PT3D and called them S2D and S3D, respectively. Irradiated volumes by 90% isodoses (VE-90%) and normal tissue volumes irradiated by 20, 50, 90% isodoses were calculated and compared using Student's paired t-test. Results. -There was a concordance of 84% of target surfaces defined on PT2D and PT3D. Percentages of target surface under- or-over defined by PT2D were 16 and 13% respectively. VE-90% was decreased by 15% (p = 0.07) with PT3D. Normal brain volume irradiated by 90% isodose was decreased by 27% with PT3D (p = 0.04). Conclusion.- For radiotherapy of cerebral tumors using only coplanar beams, PT3D leads to a reduction of normal brain tissue irradiated. We recommend PT3D for radiotherapy of cerebral tumors, particularly for low-grade or benign tumors (meningiomas, neuromas, etc.). (authors)

  20. Novel conformal technique to reduce staircasing artifacts at material boundaries for FDTD modeling of the bioheat equation

    Energy Technology Data Exchange (ETDEWEB)

    Neufeld, E [Foundation for Research on Information Technologies in Society (IT' IS), ETH Zurich, 8092 Zurich (Switzerland); Chavannes, N [Foundation for Research on Information Technologies in Society (IT' IS), ETH Zurich, 8092 Zurich (Switzerland); Samaras, T [Radiocommunications Laboratory, Aristotle University of Thessaloniki, GR-54124 Thessaloniki (Greece); Kuster, N [Foundation for Research on Information Technologies in Society (IT' IS), ETH Zurich, 8092 Zurich (Switzerland)

    2007-08-07

    The modeling of thermal effects, often based on the Pennes Bioheat Equation, is becoming increasingly popular. The FDTD technique commonly used in this context suffers considerably from staircasing errors at boundaries. A new conformal technique is proposed that can easily be integrated into existing implementations without requiring a special update scheme. It scales fluxes at interfaces with factors derived from the local surface normal. The new scheme is validated using an analytical solution, and an error analysis is performed to understand its behavior. The new scheme behaves considerably better than the standard scheme. Furthermore, in contrast to the standard scheme, it is possible to obtain with it more accurate solutions by increasing the grid resolution.

  1. Effects of Pulsed Electric Field (PEF) Treatment on Enhancing Activity and Conformation of α-Amylase.

    Science.gov (United States)

    Tian, Mei-ling; Fang, Ting; Du, Mu-ying; Zhang, Fu-sheng

    2016-04-01

    To explore an efficient, safe, and speedy application of pulsed electric field (PEF) technology for enzymatic modification, effects of PEF treatment on the enzymatic activity, property and kinetic parameters of α-amylase were investigated. Conformational transitions were also studied with the aid of circular dichroism (CD) and fluorescence spectra. The maximum enzymatic activity of α-amylase was obtained under 15 kV/cm electric field intensity and 100 mL/min flow velocity PEF treatment, in which the enzymatic activity increased by 22.13 ± 1.14% compared with control. The activation effect could last for 18 h at 4 °C. PEF treatment could widen the range of optimum temperature for α-amylase, however, it barely exerted any effect on the optimum pH. On the other hand, α-amylase treated by PEF showed an increase of Vmax, t1/2 and ΔG, whereas a decrease of Km and k were observed. Furthermore, it can be observed from fluorescence and CD spectra that PEF treatment had increased the number of amino acid residues, especially that of tryptophan, on α-amylase surface with enhanced α-helices by 34.76% and decreased random coil by 12.04% on α-amylase when compared with that of untreated. These changes in structure had positive effect on enhancing α-amylase activity and property.

  2. Assessing the quality of conformal treatment planning: a new tool for quantitative comparison

    International Nuclear Information System (INIS)

    Menhel, J; Levin, D; Alezra, D; Symon, Z; Pfeffer, R

    2006-01-01

    We develop a novel radiotherapy plan comparison index, critical organ scoring index (COSI), which is a measure of both target coverage and critical organ overdose. COSI is defined as COSI = 1 - (V(OAR) >tol /TC), where V(OAR) >tol is the fraction of volume of organ at risk receiving more than tolerance dose, and TC is the target coverage, V T,PI /V T , where V T,PI is the target volume receiving at a least prescription dose and V T is the total target volume. COSI approaches unity when the critical structure is completely spared and the target coverage is unity. We propose a two-dimensional, graphical representation of COSI versus conformity index (CI), where CI is a measure of a normal tissue overdose. We show that this 2D representation is a reliable, visual quantitative tool for evaluating competing plans. We generate COSI-CI plots for three sites: head and neck, cavernous sinus, and pancreas, and evaluate competing non-coplanar 3D and IMRT treatment plans. For all three sites this novel 2D representation assisted the physician in choosing the optimal plan, both in terms of target coverage and in terms of critical organ sparing. We verified each choice by analysing individual DVHs and isodose lines. Comparing our results to the widely used conformation number, we found that in all cases where there were discrepancies in the choice of the best treatment plan, the COSI-CI choice was considered the correct one, in several cases indicating that a non-coplanar 3D plan was superior to the IMRT plans. The choice of plan was quick, simple and accurate using the new graphical representation

  3. If additional shielding required for the linear accelerator room when modern treatment techniques are intensively used

    International Nuclear Information System (INIS)

    Miller, Albert V.; Atkocius, Vydmantas; Aleknavicius, Eduardas

    2001-01-01

    Full text: Introduction - When the new linear accelerator is to be installed in radiotherapy department the responsible personnel should perform necessary estimations and calculations of the protective barriers for the accelerator treatment room. These methods are described in details in literature. However, if modern treatment techniques are planned to be intensively used on this machine, additional concern rises regarding adequacy of these calculations. The new Saturne-43 linear accelerator with three photon energies of 8, 15 and 25 MV recently installed at our department was, planned to be used for conventional treatment techniques as well as for conformal and total body treatments. The method of conformal therapy generally employs more small fields per one treated patient than conventional techniques. It leads to the use of more linear accelerator monitor units for the average treatment. It was estimated that 'beam on' time of an accelerator to deliver the same dose to the tumor is up to 3 times more than for conventional methods. The total body technique contribute to the extra time on of an accelerator because of extended distance to the dose prescription point. Altogether intensive clinical use of these modern techniques will noticeably increase 'beam on' time of an accelerator and rise question regarding validity of the traditionally calculated shielding of the treatment room. Materials and methods - IAEA-TECDOC-1040 and NCRP Report No 49 suggest considering three main components incident on the protective barriers: direct radiation, scatter radiation and leakage radiation. The formulas for these components are similar and dose equivalent limits are proportional to the workload. For the conventional treatments workloads of direct, scattered and leakage radiation are equal and calculated by the division of total prescribed dose (for all treated per week patients) to the machine isocenter to average tissue maximum ratio. These workloads for conformal and TBI

  4. Evaluation of Sentinel Lymph Node Dose Distribution in 3D Conformal Radiotherapy Techniques in 67 pN0 Breast Cancer Patients.

    Science.gov (United States)

    Witucki, Gerlo; Degregorio, Nikolaus; Rempen, Andreas; Schwentner, Lukas; Bottke, Dirk; Janni, Wolfgang; Ebner, Florian

    2015-01-01

    Introduction. The anatomic position of the sentinel lymph node is variable. The purpose of the following study was to assess the dose distribution delivered to the surgically marked sentinel lymph node site by 3D conformal radio therapy technique. Material and Method. We retrospectively analysed 70 radiotherapy (RT) treatment plans of consecutive primary breast cancer patients with a successful, disease-free, sentinel lymph node resection. Results. In our case series the SN clip volume received a mean dose of 40.7 Gy (min 28.8 Gy/max 47.6 Gy). Conclusion. By using surgical clip markers in combination with 3D CT images our data supports the pathway of tumouricidal doses in the SN bed. The target volume should be defined by surgical clip markers and 3D CT images to give accurate dose estimations.

  5. Treatment of unicameral bone cyst: surgical technique.

    Science.gov (United States)

    Hou, Hsien-Yang; Wu, Karl; Wang, Chen-Ti; Chang, Shun-Min; Lin, Wei-Hsin; Yang, Rong-Sen

    2011-03-01

    There is a variety of treatment modalities for unicameral bone cysts, with variable outcomes reported in the literature. Although good initial outcomes have been reported, the success rate has often changed with longer-term follow-up. We introduce a novel, minimally invasive treatment method and compare its clinical outcomes with those of other methods of treatment of this lesion. From February 1994 to April 2008, forty patients with a unicameral bone cyst were treated with one of four techniques: serial percutaneous steroid and autogenous bone-marrow injection (Group 1, nine patients); open curettage and grafting with a calcium sulfate bone substitute either without instrumentation (Group 2, twelve patients) or with internal instrumentation (Group 3, seven patients); or minimally invasive curettage, ethanol cauterization, disruption of the cystic boundary, insertion of a synthetic calcium sulfate bone-graft substitute, and placement of a cannulated screw to provide drainage (Group 4, twelve patients). Success was defined as radiographic evidence of a healed cyst or of a healed cyst with some defect according to the modified Neer classification, and failure was defined as a persistent or recurrent cyst that needed additional treatment. Patients who sustained a fracture during treatment were also considered to have had a failure. The outcome parameters included the radiographically determined healing rate, the time to solid union, and the total number of procedures needed. The follow-up time ranged from eighteen to eighty-four months. Group-4 patients had the highest radiographically determined healing rate. Healing was seen in eleven of the twelve patients in that group compared with three of the nine in Group 1, eight of the twelve in Group 2, and six of the seven in Group 3. Group-4 patients also had the shortest mean time to union: 3.7 ± 2.3 months compared with 23.4 ± 14.9, 12.2 ± 8.5, and 6.6 ± 4.3 months in Groups 1, 2, and 3, respectively. This new

  6. Comparative dosimetric study of three-dimensional conformal, dynamic conformal arc, and intensity-modulated radiotherapy for brain tumor treatment using Novalis system

    International Nuclear Information System (INIS)

    Ding Meisong; Newman, Francis M.S.; Kavanagh, Brian D.; Stuhr, Kelly M.S.; Johnson, Tim K.; Gaspar, Laurie E.

    2006-01-01

    Purpose: To investigate the dosimetric differences among three-dimensional conformal radiotherapy (3D-CRT), dynamic conformal arc therapy (DCAT), and intensity-modulated radiotherapy (IMRT) for brain tumor treatment. Methods and Materials: Fifteen patients treated with Novalis were selected. We performed 3D-CRT, DCAT, and IMRT plans for all patients. The margin for the planning target volume (PTV) was 1 mm, and the specific prescription dose was 90% for all plans. The target coverage at the prescription dose, conformity index (CI), and heterogeneity index were analyzed for all plans. Results: For small tumors (PTV ≤2 cm 3 ), the three dosimetric parameters had approximate values for both 3D-CRT and DCAT plans. The CI for the IMRT plans was high. For medium tumors (PTV >2 to ≤100 cm 3 ), the three plans were competitive with each other. The IMRT plans had a greater CI, better target coverage at the prescription dose, and a better heterogeneity index. For large tumors (PTV >100 cm 3 ), the IMRT plan had good target coverage at the prescription dose and heterogeneity index and approximate CI values as those in the 3D-CRT and DCAT plans. Conclusion: The results of our study have shown that DCAT is suitable for most cases in the treatment of brain tumors. For a small target, 3D-CRT is useful, and IMRT is not recommended. For larger tumors, IMRT is superior to 3D-CRT and very competitive in sparing critical structures, especially for big tumors

  7. A Dosimetric Comparison of Accelerated Partial Breast Irradiation Techniques: Multicatheter Interstitial Brachytherapy, Three-Dimensional Conformal Radiotherapy, and Supine Versus Prone Helical Tomotherapy

    International Nuclear Information System (INIS)

    Patel, Rakesh R.; Becker, Stewart J.; Das, Rupak K.; Mackie, Thomas R.

    2007-01-01

    Purpose: To compare dosimetrically four different techniques of accelerated partial breast irradiation (APBI) in the same patient. Methods and Materials: Thirteen post-lumpectomy interstitial brachytherapy (IB) patients underwent imaging with preimplant computed tomography (CT) in the prone and supine position. These CT scans were then used to generate three-dimensional conformal radiotherapy (3D-CRT) and prone and supine helical tomotherapy (PT and ST, respectively) APBI plans and compared with the treated IB plans. Dose-volume histogram analysis and the mean dose (NTD mean ) values were compared. Results: Planning target volume coverage was excellent for all methods. Statistical significance was considered to be a p value mean dose of 1.3 Gy 3 and 1.2 Gy 3 , respectively. Both of these methods were statistically significantly lower than the supine external beam techniques. Overall, all four methods yielded similar low doses to the heart. Conclusions: The use of IB and PT resulted in greater normal tissue sparing (especially ipsilateral breast and lung) than the use of supine external beam techniques of 3D-CRT or ST. However, the choice of APBI technique must be tailored to the patient's anatomy, lumpectomy cavity location, and overall treatment goals

  8. Fabrication techniques to eliminate postweld heat treatment

    International Nuclear Information System (INIS)

    Lochhead, J.C.

    1978-01-01

    Postweld heat treatments to reduce residual stresses (stress relief operations) have been a common practice in the pressure vessel industry for a large number of years. A suitable heat treatment operation can, in particular for low alloy steels, have additional beneficial effects, i.e. a reduction in peak hardness values in the heat-affected zone, an improvement in weld metal properties, and a lowering of the adverse effects of the welding process on the mechanical properties of the parent material adjacent to the weld metal. However, continuing studies in the field of brittle fracture, improved parent materials, and more sophisticated nondestructive testing techniques have led to the elimination of such a practice in ever-increasing thickness ranges and types of material. For instance, the recently issued BS 5500 compared with BS 1113 (1969) lifts the thickness limit requiring stress relief in certain circumstances from 19 to 35mm for C steels. With respect to materials the CEGB has stated that as a result of successful operational experience it will no longer be necessary to postweld heat treat butt welds in 2 1/4 Cr-1Mo tubes of certain dimensions. Despite this trend, over a period of years a number of instances have arisen where, because of some factor, postweld heat treatment, although perhaps desirable, is not possible. This Paper describes several such examples. It must be noted that the examples quoted consist of relatively important and major items. It has been necessary within the confines of this Paper to condense the reports. It is hoped that no significant factors have been omitted. (author)

  9. Dosimetry study on the conventional and three dimensional conformal radiation treatment planning protocols for rectal cancer

    International Nuclear Information System (INIS)

    Cai Yong; He Yuxiang; Han Shukui; Wu Hao; Gong Jian; Xu Bo

    2007-01-01

    Objective: To compare the dose distribution of clinical target volume (CTV), in normal tissues and organs for patients with rectal cancer on the conventional radiotherapy (2D) and three dimension- al conformal radiation treatment (3DCRT). Methods: The CT image data of 36 rectal cancer patients treated with 3DCRT were studied. The CTV, small bowel, colon, bladder, pelvic bone marrow, and femoral head and neck were contoured on consecutive axial slices of CT images. Two 3DCRT and three conventional treatment planning protocols were simulated using three dimensional treatment planning system (CMS Focus 2.31), were defined as 3D-3, 3D-4, 2D-2, 2D-3, 2D-4. The difference of five treatment planning protocols on the CTV and normal structure by analysis of dose-volume histograms (DVHs) were compared. Results: The D 95 and V 95 of these five protocols all exceeded 97%. The conformity index(CI) of 3D was obviously larger than that of 2D protocol. The dose inhomogeneity(DI) in 4 DCRT was less than that of 3 DCRT. The 3D as compared with the 2D, significantly reduced the mean dose of 45 Gy to the small bowel and colon. The 3D-3 as compared with the 2D-3, the 3D-4 as compared with the 2D-4, the mean dose of small bowel and colon was reduced by 28.5% and 25.7%, respectively. The 3D-3 as compared with the 2D-2, the 3D-3 as compared with the 2D-3 and the 3D4 as compared with the 2D-4, the percentage volume of small bowel and colon which received 45 Gy was reduced by 80.8% , 51.1% and 54.7% , respectively. Either the mean dose, or the percentage volume receiving 35 Gy and 45 Gy to the pelvic bone and bladder, the 3D planning protocols had advanage over the 2D planning protocols. The V 45 of bladder in 2D-2 planning proto- col was the highest in all planning protocols, exceeding 98%, but the highest V 45 of bladder was only 50% in the other planning protocols. Conclusions: Even though the difference in pelvic CTV of rectal cancer patients between the conventional radiotherapy and 3

  10. Highly Conformal Craniospinal Radiotherapy Techniques Can Underdose the Cranial Clinical Target Volume if Leptomeningeal Extension through Skull Base Exit Foramina is not Contoured.

    Science.gov (United States)

    Noble, D J; Ajithkumar, T; Lambert, J; Gleeson, I; Williams, M V; Jefferies, S J

    2017-07-01

    Craniospinal irradiation (CSI) remains a crucial treatment for patients with medulloblastoma. There is uncertainty about how to manage meningeal surfaces and cerebrospinal fluid (CSF) that follows cranial nerves exiting skull base foramina. The purpose of this study was to assess plan quality and dose coverage of posterior cranial fossa foramina with both photon and proton therapy. We analysed the radiotherapy plans of seven patients treated with CSI for medulloblastoma and primitive neuro-ectodermal tumours and three with ependymoma (total n = 10). Four had been treated with a field-based technique and six with TomoTherapy™. The internal acoustic meatus (IAM), jugular foramen (JF) and hypoglossal canal (HC) were contoured and added to the original treatment clinical target volume (Plan_CTV) to create a Test_CTV. This was grown to a test planning target volume (Test_PTV) for comparison with a Plan_PTV. Using Plan_CTV and Plan_PTV, proton plans were generated for all 10 cases. The following dosimetry data were recorded: conformity (dice similarity coefficient) and homogeneity index (D 2  - D 98 /D 50 ) as well as median and maximum dose (D 2% ) to Plan_PTV, V 95% and minimum dose (D 99.9% ) to Plan_CTV and Test_CTV and Plan_PTV and Test_PTV, V 95% and minimum dose (D 98% ) to foramina PTVs. Proton and TomoTherapy™ plans were more conformal (0.87, 0.86) and homogeneous (0.07, 0.04) than field-photon plans (0.79, 0.17). However, field-photon plans covered the IAM, JF and HC PTVs better than proton plans (P = 0.002, 0.004, 0.003, respectively). TomoTherapy™ plans covered the IAM and JF better than proton plans (P = 0.000, 0.002, respectively) but the result for the HC was not significant. Adding foramen CTVs/PTVs made no difference for field plans. The mean D min dropped 3.4% from Plan_PTV to Test_PTV for TomoTherapy™ (not significant) and 14.8% for protons (P = 0.001). Highly conformal CSI techniques may underdose meninges and CSF in the dural

  11. Radiotherapy of intensity modulated VS conformational in the treatment of carcinoma of the prostate. A dosimetric comparison; Radioterapia de intensidad modulada VS conformacional en el tratamiento de carcinoma de prostata. Una camparacion dosimetrica

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Martin, G.; Garcia Vicente, F.; Zapatero Laborda, A.; Bermudez Luna, R.; Roch Gonzalez, M.; Perez Gonzalez, L.; Torres Escobar, J. J.

    2013-07-01

    The intensity modulated (IMRT) radiation therapy is a technique of high conformation which, by its nature, has as one of its main directions prostate cancer radiotherapy treatment. The purpose of this work is presents results of the dosimetric indicators collected in our hospital a number of patients of carcinoma of the prostate with standard three-dimensional Conformal technique (3D-CRT) and IMRT. Aims to demonstrate and quantify with a statistical methodology that, establishing an adequate Protocol of IMRT, significant reductions in risk organ doses can be obtained by keeping the same prescription to the white volume. (Author)

  12. Glycation and secondary conformational changes of human serum albumin: study of the FTIR spectroscopic curve-fitting technique

    Directory of Open Access Journals (Sweden)

    Yu-Ting Huang

    2016-05-01

    Full Text Available The aim of this study was attempted to investigate both the glycation kinetics and protein secondary conformational changes of human serum albumin (HSA after the reaction with ribose. The browning and fluorescence determinations as well as Fourier transform infrared (FTIR microspectroscopy with a curve-fitting technique were applied. Various concentrations of ribose were incubated over a 12-week period at 37 ± 0.5 oC under dark conditions. The results clearly shows that the glycation occurred in HSA-ribose reaction mixtures was markedly increased with the amount of ribose used and incubation time, leading to marked alterations of protein conformation of HSA after FTIR determination. In addition, the browning intensity of reaction solutions were colored from light to deep brown, as determined by optical observation. The increase in fluorescence intensity from HSA–ribose mixtures seemed to occur more quickly than browning, suggesting that the fluorescence products were produced earlier on in the process than compounds causing browning. Moreover, the predominant α-helical composition of HSA decreased with an increase in ribose concentration and incubation time, whereas total β-structure and random coil composition increased, as determined by curve-fitted FTIR microspectroscopy analysis. We also found that the peak intensity ratios at 1044 cm−1/1542 cm−1 markedly decreased prior to 4 weeks of incubation, then almost plateaued, implying that the consumption of ribose in the glycation reaction might have been accelerated over the first 4 weeks of incubation, and gradually decreased. This study first evidences that two unique IR peaks at 1710 cm−1 [carbonyl groups of irreversible products produced by the reaction and deposition of advanced glycation end products (AGEs] and 1621 cm−1 (aggregated HSA molecules were clearly observed from the curve-fitted FTIR spectra of HSA-ribose mixtures over the course of incubation time. This study

  13. Chronic rectal bleeding after high-dose conformal treatment of prostate cancer warrants modification of existing morbidity scales

    International Nuclear Information System (INIS)

    Hanlon, Alexandra L.; Schultheiss, Timothy E.; Hunt, Margie A.; Movsas, Benjamin; Peter, Ruth S.; Hanks, Gerald E.

    1997-01-01

    Purpose: Serious late morbidity (Grade (3(4))) from the conformal treatment of prostate cancer has been reported in <1% to 6% of patients based on existing late gastrointestinal (GI) morbidity scales. None of the existing morbidity scales include our most frequently observed late GI complication, which is chronic rectal bleeding requiring multiple fulgerations. This communication documents the frequency of rectal bleeding requiring multiple fulgerations and illustrates the variation in reported late serious GI complication rates by the selection of morbidity scale. Methods and Materials: Between May 1989 and December 1993, 352 patients with T1-T3 nonmetastatic prostate cancers were treated with our four-field conformal technique without special rectal blocking. This technique includes a 1-cm margin from the clinical target volume (CTV) to the planning target volume (PTV) in all directions. The median follow-up for these patients was 36 months (range 2-76), and the median center of prostate dose was 74 Gy (range 63-81). Three morbidity scales are assessed: the Radiation Therapy Oncology Group (RTOG), the Late Effects Normal Tissue Task Force (LENT), and our modification of the LENT (FC-LENT). This modification registers chronic rectal bleeding requiring at least one blood transfusion and/or more than two coagulations as a Grade 3 event. Estimates for Grade (3(4)) late GI complication rates were determined using Kaplan-Meier methodology. The duration of severe symptoms with chronic rectal bleeding is measured from the first to the last transrectal coagulation. Latency is measured from the end of radiotherapy to surgery, first blood transfusion, or third coagulation procedure. Results: Sixteen patients developed Grade (3(4)) complications by one of the three morbidity scales. Two patients required surgery (colostomy or sigmoid resection), three required multiple blood transfusions, two required one or two blood transfusions, and nine required at least three

  14. Treatment planning for conformation therapy using a multi-leaf collimator

    International Nuclear Information System (INIS)

    Boesecke, R.; Doll, J.; Bauer, B.; Schlegel, W.; Pastyr, O.; Lorenz, W.J.

    1988-01-01

    In high energy photon therapy an optimum dose distribution is achieved with an irradiation from several directions, thus adapting the field shape to the target volume. Some methods of irradiation planning using these techniques are presented. The result of such a treatment planning is demonstrated. (orig.) [de

  15. Influence of conformal radiotherapy technique on survival after chemoradiotherapy for patients with stage III non-small cell lung cancer in the National Cancer Data Base.

    Science.gov (United States)

    Sher, David J; Koshy, Matthew; Liptay, Michael J; Fidler, Mary Jo

    2014-07-01

    Definitive chemoradiotherapy is a core treatment modality for patients with stage III non-small cell lung cancer (NSCLC). Although radiotherapy (RT) technologies have advanced dramatically, to the authors' knowledge relatively little is known regarding the importance of irradiation technique on outcome, particularly given the competing risk of distant metastasis. The National Cancer Data Base was used to determine predictors of overall survival (OS) in patients with AJCC stage III NSCLC who were treated with chemoradiotherapy, focusing on the importance of conformal RT (CRT). Patients with stage III NSCLC who were treated with chemoradiotherapy between 2003 and 2005 in the National Cancer Data Base were included. RT technique was defined as conventional, 3-dimensional-conformal, or intensity-modulated RT (IMRT), the latter 2 combined as CRT. Cox proportional hazards regression was performed for univariable and multivariable analyses of OS. The median, 3-year, and 5-year survival outcomes for the 13,292 patients were 12.9 months, 19%, and 11%, respectively. The 3-year and 5-year survival probabilities of patients receiving CRT versus no CRT were 22% versus 19% and 14% versus 11%, respectively (P < .0001). On multivariable analysis, CRT was found to be significantly associated with improved OS (hazards ratio, 0.89). This effect was confirmed on sensitivity analyses, including restricting the cohort to minimum 6-month survivors, young patients with stage IIIA disease, and propensity score-matching. Institutional academic status and patient volume were not found to be associated with OS. CRT was found to be independently associated with a survival advantage. These results reflect the importance of optimal locoregional therapy in patients with stage III NSCLC and provide motivation for further study of advanced RT technologies in patients with NSCLC. © 2014 American Cancer Society.

  16. A single-gradient junction technique to replace multiple-junction shifts for craniospinal irradiation treatment

    International Nuclear Information System (INIS)

    Hadley, Austin; Ding, George X.

    2014-01-01

    Craniospinal irradiation (CSI) requires abutting fields at the cervical spine. Junction shifts are conventionally used to prevent setup error–induced overdosage/underdosage from occurring at the same location. This study compared the dosimetric differences at the cranial-spinal junction between a single-gradient junction technique and conventional multiple-junction shifts and evaluated the effect of setup errors on the dose distributions between both techniques for a treatment course and single fraction. Conventionally, 2 lateral brain fields and a posterior spine field(s) are used for CSI with weekly 1-cm junction shifts. We retrospectively replanned 4 CSI patients using a single-gradient junction between the lateral brain fields and the posterior spine field. The fields were extended to allow a minimum 3-cm field overlap. The dose gradient at the junction was achieved using dose painting and intensity-modulated radiation therapy planning. The effect of positioning setup errors on the dose distributions for both techniques was simulated by applying shifts of ± 3 and 5 mm. The resulting cervical spine doses across the field junction for both techniques were calculated and compared. Dose profiles were obtained for both a single fraction and entire treatment course to include the effects of the conventional weekly junction shifts. Compared with the conventional technique, the gradient-dose technique resulted in higher dose uniformity and conformity to the target volumes, lower organ at risk (OAR) mean and maximum doses, and diminished hot spots from systematic positioning errors over the course of treatment. Single-fraction hot and cold spots were improved for the gradient-dose technique. The single-gradient junction technique provides improved conformity, dose uniformity, diminished hot spots, lower OAR mean and maximum dose, and one plan for the entire treatment course, which reduces the potential human error associated with conventional 4-shifted plans

  17. Selection and determination of beam weights based on genetic algorithms for conformal radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Xingen Wu; Zunliang Wang

    2000-01-01

    A genetic algorithm has been used to optimize the selection of beam weights for external beam three-dimensional conformal radiotherapy treatment planning. A fitness function is defined, which includes a difference function to achieve a least-square fit to doses at preselected points in a planning target volume, and a penalty item to constrain the maximum allowable doses delivered to critical organs. Adjustment between the dose uniformity within the target volume and the dose constraint to the critical structures can be achieved by varying the beam weight variables in the fitness function. A floating-point encoding schema and several operators, like uniform crossover, arithmetical crossover, geometrical crossover, Gaussian mutation and uniform mutation, have been used to evolve the population. Three different cases were used to verify the correctness of the algorithm and quality assessment based on dose-volume histograms and three-dimensional dose distributions were given. The results indicate that the genetic algorithm presented here has considerable potential. (author)

  18. Dosimetric effect on pediatric conformal treatment plans using dynamic jaw with Tomotherapy HDA

    Energy Technology Data Exchange (ETDEWEB)

    Han, Eun Young, E-mail: eyhan@uams.edu [Department of Radiation Oncology, University of Arkansas Medical Sciences, Little Rock, AR (United States); Kim, Dong-Wook [Department of Radiation Oncology, Kyung Hee University Hospital, Seoul (Korea, Republic of); Zhang, Xin; Penagaricano, Jose; Liang, Xiaoying; Hardee, Matthew; Morrill, Steve; Ratanatharathorn, Vaneerat [Department of Radiation Oncology, University of Arkansas Medical Sciences, Little Rock, AR (United States)

    2015-10-01

    It is important to minimize the radiation dose delivered to healthy tissues in pediatric cancer treatment because of the risk of secondary malignancies. Tomotherapy HDA provides a dynamic jaw (DJ) delivery mode that creates a sharper penumbra at the craniocaudal ends of a target in addition to a fixed jaw (FJ) delivery mode. The purpose of this study was to evaluate its dosimetric effect on the pediatric cancer cases. We included 6 pediatric cases in this study. The dose profiles and plan statistics—target dose conformity, uniformity, organ-at-risk (OAR) mean dose, beam-on time, and integral dose—were compared for each case. Consequently, the target dose coverage and uniformity were similar for different jaw settings. The OAR dose sparing depended on its relative location to the target and disease sites. For example, in the head and neck cancer cases, the brain stem dose using DJ 2.5 was reduced by more than two-fold (2.4 Gy vs. 6.3 Gy) than that obtained with FJ 2.5. The integral dose with DJ 2.5 decreased by more than 9% compared with that with FJ 2.5. Thus, using dynamic jaw in pediatric cases could be critical to reduce a probability of a secondary malignancy.

  19. Dosimetric effect on pediatric conformal treatment plans using dynamic jaw with Tomotherapy HDA.

    Science.gov (United States)

    Han, Eun Young; Kim, Dong-Wook; Zhang, Xin; Penagaricano, Jose; Liang, Xiaoying; Hardee, Matthew; Morrill, Steve; Ratanatharathorn, Vaneerat

    2015-01-01

    It is important to minimize the radiation dose delivered to healthy tissues in pediatric cancer treatment because of the risk of secondary malignancies. Tomotherapy HDA provides a dynamic jaw (DJ) delivery mode that creates a sharper penumbra at the craniocaudal ends of a target in addition to a fixed jaw (FJ) delivery mode. The purpose of this study was to evaluate its dosimetric effect on the pediatric cancer cases. We included 6 pediatric cases in this study. The dose profiles and plan statistics—target dose conformity, uniformity, organ-at-risk (OAR) mean dose, beam-on time, and integral dose—were compared for each case. Consequently, the target dose coverage and uniformity were similar for different jaw settings. The OAR dose sparing depended on its relative location to the target and disease sites. For example, in the head and neck cancer cases, the brain stem dose using DJ 2.5 was reduced by more than two-fold (2.4 Gy vs. 6.3 Gy) than that obtained with FJ 2.5. The integral dose with DJ 2.5 decreased by more than 9% compared with that with FJ 2.5. Thus, using dynamic jaw in pediatric cases could be critical to reduce a probability of a secondary malignancy. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  20. CONSERVATIVE TREATMENT IN LOCALLY AND LOCALLY-ADVANCED PROSTATE CANCER USING CONFORMAL RADIOTHERAPY

    Directory of Open Access Journals (Sweden)

    Tkachev Sergey Ivanovich

    2013-01-01

    Full Text Available The combination of androgen deprivation and radiotherapy increase the probability of diseases full regresses and survival rate. Modern technical and technological opportunities of 3D CRT allow to increase total dose to prostate up to 72-76Gy vs. radiotherapy of 66-70Gy. In this study we compare the rates of post radiation toxicity and the efficiency of treatment for the patients receiving conventional radiotherapy and 3D CRT. The use of 3D CRT has not only result to increase of 10-years recurrence free survival rate from 74% (I grope to 86,5% (II grope, р=0,01, but also to increase of 10-years overall survival, 70% versus 78,4% (р=0,04. The proposed version of conformal 3D CRT radiation therapy made ​​it possible compared to conventional 2D RT radiation therapy by increasing SOD radiation to the tumor, accuracy and compliance with the quality assurance of radiation therapy significantly reduce rates of recurrence and significantly increase the performance of 10-year overall and disease-free survival.

  1. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans

    OpenAIRE

    Daniel L Saenz; Bhudatt R Paliwal; John E Bayouth

    2014-01-01

    ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60) with 0.35 Tesla magnetic resonance imaging (MRI) allows for magnetic resonance (MR)-guided intensity-modulated radiation therapy (IMRT) delivery with multiple beams. This ...

  2. Recurrent craniopharyngioma after conformal radiation in children and the burden of treatment.

    Science.gov (United States)

    Klimo, Paul; Venable, Garrett T; Boop, Frederick A; Merchant, Thomas E

    2015-05-01

    In this paper the authors present their experience treating children with recurrent craniopharyngioma who were initially managed with surgery followed by conformal radiation therapy (CRT). A departmental oncology information system was queried to identify all children (craniopharyngioma between 1998 and 2010 (inclusive) and specifically those who experienced tumor progression. For each patient, the authors recorded the type of recurrence (solid, cystic, or both), the time interval to first progression and each subsequent progression, the associated treatment complications, and disease status at last follow-up evaluation. Among the 97 patients that met criteria for entry into this study, 18 (18.6%) experienced tumor progression (9 cystic, 3 solid, 6 cystic and solid). The median time to first recurrence was 4.62 years (range 1.81-9.11 years). The subgroup included 6 female and 12 male patients with a median age of 7.54 years (range 3.61-13.83 years). Ten patients experienced first progression within 5 years of CRT. The 5- and 10-year treatment-free survival rates for the entire cohort were 89.0% (95% confidence interval [CI] 80.5%-93.9%) and 76.2% (95% CI 64%-85%), respectively. Seven patients had a single episode of progression and 11 had more than 1. The time interval between each subsequent progression was progressively shorter. The 18 patients underwent 38 procedures. The median follow-up duration for this group was 9.32 years (range 4.04-19.0 years). Three patients died, including 1 from perioperative complications. Craniopharyngioma progression after prior irradiation is exceedingly difficult to treat and local control is challenging despite repeated surgical procedures. Given our results, gross-total resection may need to be the surgical goal at the time of first recurrence, if possible. Decompressing new cyst formation alone has a low rate of long-term success.

  3. 3D-conformal radiotherapy treatment of high grade gliomas of malignancy

    International Nuclear Information System (INIS)

    Chon Rivas, Ivonne; Chi Ramirez, Daysi; Alert Silva, Jose; Roca Muchuli, Carlos; Leon Gonzalez, Roberto; Perez Penna, Lourdes

    2009-01-01

    Patients diagnosed with high grade gliomas of malignancy (A), have a high mortality rate, about 10% achieve survivals than one year due to poor local control resulting from the inability of high doses of radiation to tumor volume by dose-limiting provided by healthy peritumoral tissues and structures. 3D conformal radiotherapy (RT-3DC) achieves effective tumoricidal high doses with high precision on the tumor with minimal involvement of critical structures near the tumor target volume. From 2005 until 2008 at INOR, a total of 23 patients with histologically confirmed supratentorial gliomas location, histological subtypes of anaplastic astrocytoma (AA) in 8 patients (35%) and Glioblastoma Multiforme (GBM) in 15 patients (65%), aged between 18 and 65, Karnofski scale of 70 or more and total previous surgical resection in 10 patients (43%) or partial in 13 (57%) were included prospectively in this study. The total tumor dose of 66-70 Gy was prescribed with a daily fractionation of 1.8 Gy. All patients underwent CT images (CT) and MRI (MRI) cranial volumes were defined treatment planning according to the concepts of ICRU 50 and 62 with precise immobilization of the head by thermo deformed mask, CT 3mm cuts planning system and 3D treatment planning. Median survival was better in patients younger than 55 years, with high rates of Karnofski, histology of AA and higher percentage of surgical resection. Median survival (Kaplan-Meier method) obtained was 16 months. Survival at 1 and 2 years was 51% and 28% respectively. The RT-3DC can administer higher doses on the tumor with peritumoral healthy protection structures in selected patients with a diagnosis of AA or GBM, increasing local control and potentially overall survival without exacerbating toxicity, thus demonstrating the dose- response of malignant brain tumors. (Author)

  4. Rectal bleeding after conformal 3D treatment of prostate cancer: time to occurrence, response to treatment and duration of morbidity

    International Nuclear Information System (INIS)

    Teshina, Teruki; Hanks, Gerald E.; Peters, Ruth S.; Hanlon, Alexandra L.; Schultheiss, Timothy E.

    1996-01-01

    Purpose: Late rectal bleeding is the most common sequelae of high dose 3D conformal treatment (3DCRT) for prostate cancer and limits attempts to improve local control by dose escalation. The clinical course of this complication is reported including time to onset, response to treatment, duration of morbidity and risk factor analysis by multivariate analysis. Materials and Methods: From March, 1989 to June 1996, 670 patients with prostate cancer were treated with 3DCRT. Eighty-nine patients developed grade 2 or 3 complications due to rectal bleeding and are analyzed (Grade 2 LENT scale, Grade 3 Fox Chase modification of LENT including >2 coagulations as Grade 3). They are compared to 581 patients without Grade 2,3 morbidity in multivariate analysis. Time to development, response to initial and retreatment and duration of morbidity are tabulated. Results: The median time to occurrence is not significantly different (p=.09) for Grade 2 (13 mo. range 4-41 mo.) compared to Grade 3 (18 mo. range 4-40 mo.). The corresponding median duration of symptoms >Grade 1 were significantly different (p=.0001) being 1 month (range 1-<12) versus 10 months (1-34) respectively. The response to treatment and retreatment is shown in Table 1. For Grade 2 complications medication or coagulation was highly effective as initial or retreatment resolving 66 of 73 patients. For Grade 3 a few responded to only transfusion and with multiple coagulations and medication (12(16)) patients improved to ≤ Grade 1. Multivariate analysis demonstrates that dose is the only significant factor associated with Grade 2 (LENT) (p=.01) or Grade 3 (FC-LENT) (p=.01) complication. Lack of response to treatment was associated with hypertension on univariate analysis only. Of 7 non-responders to treatment of Grade 2 bleeding, 3 have died of intercurrent disease at 10, 19 and 26 months while 4 are alive with continuing Grade 2 bleeding at 26, 34, 41 and 45 months after onset. Of 4 non-responders to treatment of

  5. Rectal bleeding after conformal 3D treatment of prostate cancer: Time to occurrence, response to treatment and duration of morbidity

    International Nuclear Information System (INIS)

    Teshima, Teruki; Hanks, Gerald E.; Hanlon, Alexandra L.; Peter, Ruth S.; Schultheiss, Timothy E.

    1997-01-01

    Purpose: Rectal bleeding is the most common late sequelae of high-dose 3D conformal treatment (3DCRT) for prostate cancer and may limit attempts to improve local control by dose escalation. The clinical course of this complication is reported including time to onset, response to treatment, duration of morbidity, and multivariate analysis for predictors. Methods and Materials: From March 1989 to June 1995, 670 patients with prostate cancer were treated with 3DCRT at Fox Chase Cancer Center. Eighty-nine patients developed Grade 2 or Grade 3 complications due to rectal bleeding and are analyzed. Multivariate analysis results for predictors of Grade 2 and 3 rectal bleeding are reported as well as time to development, response to initial and retreatment, and duration of morbidity. Results: The median time to occurrence is not significantly different (p = 0.09) for Grade 2 (13 months, range 4-41 months) compared to Grade 3 rectal bleeding (18 months, range 4-40 months), while the corresponding median duration of symptoms was significantly different (p < 0.0001) being 1 month (range 1-12) vs. 10 months (1-34) for Grade 2 and Grade 3 bleeding, respectively. For Grade 2 bleeding, medication or coagulation was highly effective as initial or retreatment resolving 66 of 73 patients. For Grade 3 bleeding, three patients responded without medication following blood transfusion only, while with multiple coagulations and medication 12 of 16 patients improved to ≤ Grade 1. Multivariate analysis demonstrates that dose is the only significant factor associated with Grade 2 (p = 0.01) or Grade 3 (p = 0.01) rectal bleeding. Of seven nonresponders to treatment for Grade 2 bleeding, three have died of intercurrent disease at 10, 19, and 26 months, while four are alive with continuing Grade 2 bleeding at 12, 14, 15, and 30 months after onset. The four nonresponders to treatment for Grade 3 bleeding continue to bleed 1, 9, 32, and 35 months after the third coagulation despite continuing

  6. Impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans

    International Nuclear Information System (INIS)

    Kubo, H. Dale; Wilder, Richard B.; Pappas, Conrad T.E.

    1999-01-01

    Purpose: The authors undertook a study to analyze the impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans. Methods and Materials: Twelve cases involving primary brain tumors, metastases, or arteriovenous malformations that had been planned with BrainLAB's conventional circular collimator-based radiosurgery system were re-planned using a β-version of BrainLAB's treatment planning software that is compatible with MRC Systems' and BrainLAB's micro-multileaf collimators. These collimators have a minimum leaf width of 1.7 mm and 3.0 mm, respectively, at isocenter. The clinical target volumes ranged from 2.7-26.1 cc and the number of static fields ranged from 3-5. In addition, for 4 prostate cancer cases, 2 separate clinical target volumes were planned using MRC Systems' and BrainLAB's micro-multileaf collimators and Varian's multileaf collimator: the smaller clinical target volume consisted of the prostate gland and the larger clinical target volume consisted of the prostate and seminal vesicles. For the prostate cancer cases, treatment plans were generated using either 6 or 7 static fields. A 'PITV ratio', which the Radiation Therapy Oncology Group defines as the volume encompassed by the prescription isodose surface divided by the clinical target volume, was used as a measure of the quality of treatment plans (a PITV ratio of 1.0-2.0 is desirable). Bladder and rectal volumes encompassed by the prescription isodose surface, isodose distributions and dose volume histograms were also analyzed for the prostate cancer patients. Results: In 75% of the cases treated with radiosurgery, a PITV ratio between 1.0-2.0 could be achieved using a micro-multileaf collimator with a leaf width of 1.7-3.0 mm at isocenter and 3-5 static fields. When the clinical target volume consisted of the prostate gland, the micro-multileaf collimator with a minimum leaf width of 3.0 mm allowed one to decrease the median volume of bladder and

  7. Radiation treatment planning techniques for lymphoma of the stomach

    International Nuclear Information System (INIS)

    Della Biancia, Cesar; Hunt, Margie; Furhang, Eli; Wu, Elisa; Yahalom, Joachim

    2005-01-01

    Purpose: Involved-field radiation therapy of the stomach is often used in the curative treatment of gastric lymphoma. Yet, the optimal technique to irradiate the stomach with minimal morbidity has not been well established. This study was designed to evaluate treatment planning alternatives for stomach irradiation, including intensity-modulated radiation therapy (IMRT), to determine which approach resulted in improved dose distribution and to identify patient-specific anatomic factors that might influence a treatment planning choice. Methods and Materials: Fifteen patients with lymphoma of the stomach (14 mucosa-associated lymphoid tissue lymphomas and 1 diffuse large B-cell lymphoma) were categorized into 3 types, depending on the geometric relationship between the planning target volume (PTV) and kidneys. AP/PA and 3D conformal radiation therapy (3DCRT) plans were generated for each patient. IMRT was planned for 4 patients with challenging geometric relationship between the PTV and the kidneys to determine whether it was advantageous to use IMRT. Results: For type I patients (no overlap between PTV and kidneys), there was essentially no benefit from using 3DCRT over AP/PA. However, for patients with PTVs in close proximity to the kidneys (type II) or with high degree of overlap (type III), the 4-field 3DCRT plans were superior, reducing the kidney V 15Gy by approximately 90% for type II and 50% for type III patients. For type III, the use of a 3DCRT plan rather than an AP/PA plan decreased the V 15Gy by approximately 65% for the right kidney and 45% for the left kidney. In the selected cases, IMRT led to a further decrease in left kidney dose as well as in mean liver dose. Conclusions: The geometric relationship between the target and kidneys has a significant impact on the selection of the optimum beam arrangement. Using 4-field 3DCRT markedly decreases the kidney dose. The addition of IMRT led to further incremental improvements in the left kidney and liver

  8. Evaluation of conformal radiotherapy techniques through physics and biologic criteria; Avaliacao de tecnicas radioterapicas conformacionais utilizando criterios fisicos e biologicos

    Energy Technology Data Exchange (ETDEWEB)

    Bloch, Jonatas Carrero

    2012-07-01

    In the fight against cancer, different irradiation techniques have been developed based on technological advances and aiming to optimize the elimination of tumor cells with the lowest damage to healthy tissues. The radiotherapy planning goal is to establish irradiation technical parameters in order to achieve the prescribed dose distribution over the treatment volumes. While dose prescription is based on radiosensitivity of the irradiated tissues, the physical calculations on treatment planning take into account dosimetric parameters related to the radiation beam and the physical characteristics of the irradiated tissues. To incorporate tissue's radiosensitivity into radiotherapy planning calculations can help particularize treatments and establish criteria to compare and elect radiation techniques, contributing to the tumor control and the success of the treatment. Accordingly, biological models of cellular response to radiation have to be well established. This work aimed to study the applicability of using biological models in radiotherapy planning calculations to aid evaluating radiotherapy techniques. Tumor control probability (TCP) was studied for two formulations of the linear-quadratic model, with and without repopulation, as a function of planning parameters, as dose per fraction, and of radiobiological parameters, as the α/β ratio. Besides, the usage of biological criteria to compare radiotherapy techniques was tested using a prostate planning simulated with Monte Carlo code PENELOPE. Afterwards, prostate planning for five patients from the Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto, USP, using three different techniques were compared using the tumor control probability. In that order, dose matrices from the XiO treatment planning system were converted to TCP distributions and TCP-volume histograms. The studies performed allow the conclusions that radiobiological parameters can significantly influence tumor control

  9. A comparison of four patient immobilization devices in the treatment of prostate cancer patients with three dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Song, Paul Y.; Washington, Maxine; Vaida, Florin; Hamilton, Russell; Spelbring, Danny; Wyman, Brenda; Harrison, Joanne; Chen, George T. Y.; Vijayakumar, Srinivasan

    1996-01-01

    Purpose: To determine the variability of patient positioning during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer treated with no immobilization or one of four immobilization devices, and to determine the effects of patient body habitus and pelvic circumference on patient movement with each individual immobilization technique. Methods and Materials: To see whether our immobilization techniques have improved day-to-day patient movement, a retrospective analysis was carried out. A total of 62 patients treated at one facility on a single machine with 3D-CRT via a four-field box technique (anterior-posterior and opposed laterals) in the supine position with either no immobilization or one of four immobilization devices. Five groups of patients were compared: (a) group 1-no immobilization; (b) group 2-alpha cradle from the waist to upper thigh; (c) group 3-alpha cradle from waist to below the knees; (d) group 4-styrofoam leg immobilizer (below knees); and (e) group 5-aquaplast cast encompassing the entire abdomen and pelvis to midthigh with alpha cradle immobilization to their lower legs and feet. Prior to starting radiotherapy, portal films of all four treatment fields were obtained 1 day before treatment. Subsequently, portal films were then obtained at least once a week. Portal films were compared with the simulation films and appropriate changes were made and verified on the next day prior to treatment. A deviation of greater than 0.5 cm or greater was considered to be clinically significant in our analysis. We studied the difference among the types of immobilization and no immobilization by looking at the frequency of movements (overall, and on each of the three axes) that a patient had during the course of his treatment. Using a logistic regression model, the probability of overall and individual directional movement for each group was obtained. In addition, the effects of patient body habitus and pelvic circumference on movement were

  10. The role of Cobalt-60 source in Intensity Modulated Radiation Therapy: From modeling finite sources to treatment planning and conformal dose delivery

    Science.gov (United States)

    Dhanesar, Sandeep Kaur

    Cobalt-60 (Co-60) units played an integral role in radiation therapy from the mid-1950s to the 1970s. Although they continue to be used to treat cancer in some parts of the world, their role has been significantly reduced due to the invention of medical linear accelerators. A number of groups have indicated a strong potential for Co-60 units in modern radiation therapy. The Medical Physics group at the Cancer Center of the Southeastern Ontario and Queen's University has shown the feasibility of Intensity Modulated Radiation Therapy (IMRT) via simple conformal treatment planning and dose delivery using a Co-60 unit. In this thesis, initial Co-60 tomotherapy planning investigations on simple uniform phantoms are extended to actual clinical cases based on patient CT data. The planning is based on radiation dose data from a clinical Co-60 unit fitted with a multileaf collimator (MLC) and modeled in the EGSnrc Monte Carlo system. An in house treatment planning program is used to calculate IMRT dose distributions. Conformal delivery in a single slice on a uniform phantom based on sequentially delivered pencil beams is verified by Gafchromic film. Volumetric dose distributions for Co-60 serial tomotherapy are then generated for typical clinical sites that had been treated at our clinic by conventional 6MV IMRT using Varian Eclipse treatment plans. The Co-60 treatment plans are compared with the clinical IMRT plans using conventional matrices such as dose volume histograms (DVH). Dose delivery based on simultaneously opened MLC leaves is also explored and a novel MLC segmentation method is proposed. In order to increase efficiency of dose calculations, a novel convolution based fluence model for treatment planning is also proposed. The ion chamber measurements showed that the Monte Carlo modeling of the beam data under the MIMiC MLC is accurate. The film measurements from the uniform phantom irradiations confirm that IMRT plans from our in-house treatment planning system

  11. Three dimensional conformal radiotherapy for the treatment of prostate cancer: low risk of chronic rectal morbidity observed in a large series of patients

    International Nuclear Information System (INIS)

    Sandler, Howard M.; McLaughlin, P. William; Ten Haken, Randall K.; Addison, Heather; Forman, Jeffrey; Lichter, Allen

    1995-01-01

    Purpose: Three dimensional conformal radiotherapy (3D CRT) may provide a technique to increase the dose delivered to target tissues while sparing uninvolved normal structures. To evaluate the role of 3D treatment in reducing the treatment toxicity, we analyzed the chronic rectal morbidity observed in a large group of patients undergoing radiotherapy for prostate cancer. Methods and Materials: From 1987 through 1992, 721 prostate cancer patients were treated with 3D CRT at the University of Michigan or Providence Hospital. All had axial computed tomography (CT) specifically for RT planning, multiple structures contoured on the axial images, and beam's-eye-view conformal beams edited to provide 3D dose coverage. Using current American Joint Commission (AJCC) staging, 537 patients had T1-T2 tumors, 123 had T3-T4 tumors, and 60 were treated postprostatectomy. Pelvic lymph nodes were treated in 462 patients. Prostate boosts were delivered with four-field axial, six-field axial, or four-field oblique, nonaxial fields. The median dose was 68.40 Gy (range 59.4-80.4). Median follow-up was 20.4 months; 175 were followed more than 3 years. All complications have been graded conservatively using the RTOG system. Results: Using a Cox proportional hazard's model, patient age, T-stage, prescribed dose, pelvic treatment, and boost technique were analyzed. The factor most strongly related to risk of morbidity was dose (p = 0.05); however, the boost technique was also related: the four-field oblique field had the lowest relative risk. Most episodes of rectal morbidity have been mild: 82 Grade 1 or 2. There have been only 14 more serious complications including 12 Grade 3 and 2 Grade 4. The actuarial risk of a Grade 3 or 4 complication is 3% at 3 and 5 years. Conclusions: A very small proportion of patients treated with 3D CRT had significant rectal morbidity related to RT, supporting the use of conformal treatment planning and dose delivery as a mechanism to minimize complications

  12. CT-image based conformal brachytherapy of breast cancer. The significance of semi-3-D and 3-D treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Polgar, C.; Major, T.; Somogyi, A.; Takacsi-Nagy, Z.; Mangel, L.C.; Fodor, J.; Nemeth, G. [Orszagos Onkologiai Intezet, Budapest (Hungary). Dept. of Radiotherapy; Forrai, G. [Haynal Imre Univ. of Health Sciences, Budapest (Hungary). Dept. of Radiology; Sulyok, Z. [Orszagos Onkologiai Intezet, Budapest (Hungary). Dept. of Surgery

    2000-03-01

    In 103 patients with T1-2, N0-1 breast cancer the tumor bed was clipped during breast conserving surgery. Fifty-two of them received boost brachytherapy after 46 to 50 Gy teletherapy and 51 patients were treated with brachytherapy alone via flexible implant tubes. Single double and triple plane implant was used in 6,89 and 8 cases, respectively. The dose of boost brachytherapy and sole brachytherapy prescribed to dose reference points was 3 times 4.75 Gy and 7 times 5.2 Gy, respectively. The positions of dose reference points varied according to the level (2-D, semi-3-D and 3-D) of treatment planning performed. The treatment planning was based on the 3-D reconstruction of the surgical clips, implant tubes and skin points. In all cases the implantations were planned with a semi-3-D technique aided by simulator. In 10 cases a recently developed CT-guided 3-D planning system was used. The semi-3D and 3-D treatment plans were compared to hypothetical 2-D plans using dose-volume histograms and dose non-uniformity ratios. The values of mean central dose, mean skin dose, minimal clip dose, proportion of underdosaged clips and mean target surface dose were evaluated. The accuracy of tumor bed localization and the conformity of planning target volume and treated volume were also analyzed in each technique. Results: With the help of conformal semi-3D and 3D brachytherapy planning we could define reference dose points, active source positions and dwell times individually. This technique decreased the mean skin dose with 22.2% and reduced the possibility of geographical miss. We could achieve the best conformity between the planning target volume and the treated volume with the CT-image based 3-D treatment planning, at the cost of worse dose homogeneity. The mean treated volume was reduced by 25.1% with semi-3-D planning, however, its was increased by 16.2% with 3-D planning, compared to the 2-D planning. (orig.) [German] Bei 103 Patientinnen mit Mammakarzinom der Stadien T1

  13. Hippocampal sparing radiotherapy for pediatric medulloblastoma: impact of treatment margins and treatment technique

    DEFF Research Database (Denmark)

    Brodin, N. Patrik; af Rosenschold, Per Munck; Blomstrand, Malin

    2014-01-01

    BackgroundWe investigated how varying the treatment margin and applying hippocampal sparing and proton therapy impact the risk of neurocognitive impairment in pediatric medulloblastoma patients compared with current standard 3D conformal radiotherapy.MethodsWe included 17 pediatric medulloblastoma...

  14. Method of making large area conformable shape structures for detector/sensor applications using glass drawing technique and postprocessing

    Science.gov (United States)

    Ivanov, Ilia N [Knoxville, TN; Simpson, John T [Clinton, IN

    2012-01-24

    A method of making a large area conformable shape structure comprises drawing a plurality of tubes to form a plurality of drawn tubes, and cutting the plurality of drawn tubes into cut drawn tubes of a predetermined shape. The cut drawn tubes have a first end and a second end along the longitudinal direction of the cut drawn tubes. The method further comprises conforming the first end of the cut drawn tubes into a predetermined curve to form the large area conformable shape structure, wherein the cut drawn tubes contain a material.

  15. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans

    International Nuclear Information System (INIS)

    Saenz, Daniel L.; Paliwal, Bhudatt R.; Bayouth, John E.

    2014-01-01

    ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 ( 60 Co) with 0.35 Tesla magnetic resonance imaging (MRI) allows for magnetic resonance (MR)-guided intensity-modulated radiation therapy (IMRT) delivery with multiple beams. This study investigated head and neck, lung, and prostate treatment plans to understand what is possible on ViewRay to narrow focus toward sites with optimal dosimetry. The goal is not to provide a rigorous assessment of planning capabilities, but rather a first order demonstration of ViewRay planning abilities. Images, structure sets, points, and dose from treatment plans created in Pinnacle for patients in our clinic were imported into ViewRay. The same objectives were used to assess plan quality and all critical structures were treated as similarly as possible. Homogeneity index (HI), conformity index (CI), and volume receiving 60 Co ViewRay treatments planned with its Monte Carlo treatment planning software were comparable with 6 MV plans computed with convolution superposition algorithm on Pinnacle treatment planning system. (author)

  16. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans.

    Science.gov (United States)

    Saenz, Daniel L; Paliwal, Bhudatt R; Bayouth, John E

    2014-04-01

    ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60) with 0.35 Tesla magnetic resonance imaging (MRI) allows for magnetic resonance (MR)-guided intensity-modulated radiation therapy (IMRT) delivery with multiple beams. This study investigated head and neck, lung, and prostate treatment plans to understand what is possible on ViewRay to narrow focus toward sites with optimal dosimetry. The goal is not to provide a rigorous assessment of planning capabilities, but rather a first order demonstration of ViewRay planning abilities. Images, structure sets, points, and dose from treatment plans created in Pinnacle for patients in our clinic were imported into ViewRay. The same objectives were used to assess plan quality and all critical structures were treated as similarly as possible. Homogeneity index (HI), conformity index (CI), and volume receiving ViewRay treatments planned with its Monte Carlo treatment planning software were comparable with 6 MV plans computed with convolution superposition algorithm on Pinnacle treatment planning system.

  17. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans

    Directory of Open Access Journals (Sweden)

    Daniel L Saenz

    2014-01-01

    Full Text Available ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60 with 0.35 Tesla magnetic resonance imaging (MRI allows for magnetic resonance (MR-guided intensity-modulated radiation therapy (IMRT delivery with multiple beams. This study investigated head and neck, lung, and prostate treatment plans to understand what is possible on ViewRay to narrow focus toward sites with optimal dosimetry. The goal is not to provide a rigorous assessment of planning capabilities, but rather a first order demonstration of ViewRay planning abilities. Images, structure sets, points, and dose from treatment plans created in Pinnacle for patients in our clinic were imported into ViewRay. The same objectives were used to assess plan quality and all critical structures were treated as similarly as possible. Homogeneity index (HI, conformity index (CI, and volume receiving <20% of prescription dose (DRx were calculated to assess the plans. The 95% confidence intervals were recorded for all measurements and presented with the associated bars in graphs. The homogeneity index (D5/D95 had a 1-5% inhomogeneity increase for head and neck, 3-8% for lung, and 4-16% for prostate. CI revealed a modest conformity increase for lung. The volume receiving 20% of the prescription dose increased 2-8% for head and neck and up to 4% for lung and prostate. Overall, for head and neck Co-60 ViewRay treatments planned with its Monte Carlo treatment planning software were comparable with 6 MV plans computed with convolution superposition algorithm on Pinnacle treatment planning system.

  18. Development of Radiation Technique for Environmental Treatment

    International Nuclear Information System (INIS)

    Lee, Myun Joo; Kuk, Il Hiun; Jin, Joon Ha

    2007-02-01

    The purpose of this research is to development of technologies for 1) the removal of toxic organic chemicals in sewage sludges and the volume reduction of the sewage sludge 2) the recycling/reuse of sewage sludge 3) the reconvey of resource from fishery waste by using radiation technologies. This research project focused on the study of treatment, disposal, and recycling/reuse of sewage sludge by radiation technology, and recovery of highly value-added resources from the wastes. As basic studies with a radiation technology, an enhancement of dewaterbilities of sewage sludge, development of dewatering conditioner, reduction of trace toxic organic chemicals, and the toxicities of the byproducts were studied. Based on the basic experimental results, we developed the pilot-scale system with the continuous e-beam and dewatering unit and the advanced treatment system with the use of carbon source recovered from sewage sludge

  19. Development of Radiation Technique for Environmental Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myun Joo; Kuk, Il Hiun; Jin, Joon Ha [and others

    2007-02-15

    The purpose of this research is to development of technologies for 1) the removal of toxic organic chemicals in sewage sludges and the volume reduction of the sewage sludge 2) the recycling/reuse of sewage sludge 3) the reconvey of resource from fishery waste by using radiation technologies. This research project focused on the study of treatment, disposal, and recycling/reuse of sewage sludge by radiation technology, and recovery of highly value-added resources from the wastes. As basic studies with a radiation technology, an enhancement of dewaterbilities of sewage sludge, development of dewatering conditioner, reduction of trace toxic organic chemicals, and the toxicities of the byproducts were studied. Based on the basic experimental results, we developed the pilot-scale system with the continuous e-beam and dewatering unit and the advanced treatment system with the use of carbon source recovered from sewage sludge.

  20. CT-image based conformal high-dose rate brachytherapy boost in the conservative treatment of stage I - II breast cancer - introducing the procedure

    International Nuclear Information System (INIS)

    Kubaszewska, M.; Skowronek, J.; Chichel, A.; Kanikowski, M.; Dymnicka, M.

    2008-01-01

    Aim: Breast-conserving surgery (BCS) followed by radiotherapy (RT) has become the standard treatment for the majority of patients with early breast cancer. With regard to boost technique some disagreements are found between groups that are emphasizing the value of electron boost treatment and groups pointing out the value of interstitial brachytherapy (BT) boost treatment. We present the preliminary results in treating selected patients with early-stage breast cancer using high-dose-rate brachytherapy (HD R-BT) as a boost after breast conservation therapy (BCT). Materials/Methods: Between January 2006 and August 2007, a total of 58 female patients with first and second stage breast cancer underwent BCT. This therapeutic procedure involves BCS, whole breast radiation therapy (WBRT) and additional irradiation to the tumour bed (boost) using interstitial HDR-BT via flexible implant tubes. A 10 Gy boost dose was received by all patients. The treatment planning was based on CT-guided 3D (three-dimensional) reconstruction of the surgical clips, implant tubes and critical structures localization (skin and ribs). The accuracy of tumour bed localization, the conformity of planning target volume and treated volume were analyzed. Results: The evaluations of implant parameters involved the use of: dose volume histogram (DVH), the volume encompassed by the 100% reference isodose surface (V100%), the high dose volumecalculation (V150%, V200%, V300%), the dose non-uniformity ratio (DNR), and the conformity index (COIN). Our results were as follows: the mean PTV volume, the mean high dose volume (V150%; V200%; V300%), the DNR and COIN mean value were estimated at 57.38, 42.98, 21.38, 7.90, 0.52 and 0.83 respectively. Conclusions: CT-guided 3D HDR-BT is most appropriate for planning the boost procedure after BT especially in large breast volume, in cases with a deep seated tumour bed, as well as in patients with high risk for local recurrences. This technique reduces the

  1. Method and techniques of radioactive waste treatment

    International Nuclear Information System (INIS)

    Ghafar, M.; Aasi, N.

    2002-04-01

    This study illustrates the characterization of radioactive wastes produced by the application of radioisotopes in industry and research. The treatment methods of such radioactive wastes, chemical co-precipitation and ion exchange depending on the technical state of radioactive waste management facility in Syria were described. The disposal of conditioned radioactive wastes, in a safe way, has been discussed including the disposal of the radioactive sources. The characterizations of the repository to stock conditioned radioactive wastes were mentioned. (author)

  2. Treatment of Moya Moya disease using indirect surgery technique

    Directory of Open Access Journals (Sweden)

    Cezary Grochowski

    2016-08-01

    Conclusion: Presented technique is preferred among children suffering from moya moya disease because of the safety of the technique and good treatment effects. There is no need to perform by-pass surgery which is also considered as big advantage of presented technique.

  3. Conformal, planarizing and bridging AZ5214-E layers deposited by a 'draping' technique on non-planar III V substrates

    Science.gov (United States)

    Eliás, P.; Strichovanec, P.; Kostic, I.; Novák, J.

    2006-12-01

    A draping technique was tested for the deposition of positive-tone AZ5214-E photo-resist layers on non-planar (1 0 0)-oriented III-V substrates, which had a variety of three-dimensional (3D) topographies micromachined in them that consisted, e.g., of mesa ridges confined to side facets with variable tilt, inverted pyramidal holes and stubs confined to perpendicular side facets. All objects were sharp-edged. In each draping experiment, an AZ5214-E sheet was (1) formed floating on the water surface, (2) lowered onto a non-planar substrate and (3) draped over it during drying to form either self-sustained, or conformal, or planarizing layers over the non-planar substrates. The draping process is based on the depression of the glass transition temperature Tg of AZ5214-E material induced by penetrant water molecules that interact with AZ5214-E. During the process, the molecules are initially trapped under an AZ5214-E sheet and then transported out through the sheet via permeation. The water-AZ5214-E interaction modifies the stiffness κ of the sheet. The magnitude of the effect depends on temperature T and on partial water vapour pressure difference p(T, P, κ): the net effect is that Tg = f(C(T, P), p(T, P, κ)) is lowered as the concentration C of water increases with T and p, where P is the permeability of the sheet. The interaction depressed the Tg of the sheets as low as or lower than 53 °C for 6 µm thick sheets. At room temperature T Tg, the sheet becomes rubbery and mouldable by adhesion and capillary forces. As a result, it can either contour or planarize the topography depending on its geometry and thickness of the sheet.

  4. Comparison study of the partial-breast irradiation techniques: Dosimetric analysis of three-dimensional conformal radiation therapy, electron beam therapy, and helical tomotherapy depending on various tumor locations

    International Nuclear Information System (INIS)

    Kim, Min-Joo; Park, So-Hyun; Son, Seok-Hyun; Cheon, Keum-Seong; Choi, Byung-Ock; Suh, Tae-Suk

    2013-01-01

    The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dose homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue

  5. Factors related to late GI and GU complications in conformal and conventional radiation treatment of cancer of the prostate

    International Nuclear Information System (INIS)

    Schultheiss, Timothy E.; Lee, W. Robert; Hunt, Margie A.; Hanlon, Alexandra L.; Peter, Ruth S.; Hanks, Gerald E.

    1995-01-01

    Purpose: To assess the factors that predict for late GI and GU morbidity in radiation treatment of the prostate. Materials and Methods: Six hundred sixteen consecutive prostate cancer patients treated between 1985 and 1994 with conformal or conventional techniques were included in the analysis. All patients had at least 3 months followup (median 26 months) and received at least 65 Gy. Late GI morbidity was rectal bleeding (requiring more than 2 procedures) or proctitis. Late GU morbidity was cystitis or stricture. Univariate analysis compared the differences in the incidence of RTOG-EORTC grade 3 and 4 late morbidity by age (<60 versus ≥ 60 years), peracute side effects ≥ grade 1 (during treatment), subacute side effects ≥ grade 1 (0 to 90 days after treatment), irradiated volume parameters, and dose. Multivariate proportional hazards analysis includes these same variables in a model of time to complication. Multivariate logistic regression was used to analyze incidence of peracute and subacute GI and GU side effects by GI and GU comorbidities, performance status, pretreatment procedures (biopsy, TURP, etc.), age, treatment volume parameters, and peracute responses. Results: Peracute GI and GU side effects were noted in 441 and 442 patients, respectively. Subacute GI and GU side effects were noted in 34 and 54 patients, respectively. Subacute GI side effects were highly correlated with subacute GU side effects (p<0.00001). Late morbidities were not correlated with peracute side effects but were correlated with subacute side effects (both GI and GU). Thirteen of the 616 patients expressed grade 3 or 4 GI injuries 3 to 32 months after the end of treatment, with a mean of 13 months. The 6 GU morbidities occurred significantly later (9 - 52 months) with a mean of 33 months. Central axis dose and age less than 60 years were the only independent variables significantly related to the incidence of late GI morbidity on multivariate analysis. Subacute and peracute

  6. Irradiation techniques for the breast cancer treatment

    International Nuclear Information System (INIS)

    Varon T, C.F.; Rojas C, E.L.

    2007-01-01

    The radiotherapy is a cancer treatment way based on the radiation employment. It acts on the tumor, destroying the wicked cells and impeding that this it grows and reproduce. With the radiotherapy the probability of cure of some types of cancer; among them the one of breast, it increases. The investigations in oncology have allowed to develop new technologies with which is possible, for example, to locate the tumors accurately and to adapt the irradiation fields to their form. This has allowed to improve the treatments since it can destroy the tumor applying an intense radiation dose without producing irreversible damages to other organs and healthy tissues of the body. In the underdeveloped countries or in development as Mexico, and almost all those of Latin America, it is not still possible to have several of these technologies in the main oncological centers of the country by their high cost. It is expected that their cost go lowering and that its going to develop technologies more cheap so that they can be applied in more general way to the population that suffers of this suffering. (Author)

  7. Long-Term Results of a Highly Performing Conformal Electron Therapy Technique for Chest Wall Irradiation After Mastectomy

    Energy Technology Data Exchange (ETDEWEB)

    Grellier Adedjouma, Noemie, E-mail: grellier.noemie@gmail.com [Department of Radiation Oncology, Institut Curie, Paris (France); Chevrier, Marion [Department of Biostatistics, Institut Curie, Paris (France); Fourquet, Alain; Costa, Emilie; Xu, Haoping [Department of Radiation Oncology, Institut Curie, Paris (France); Berger, Frederique [Department of Biostatistics, Institut Curie, Paris (France); Campana, Francois [Department of Radiation Oncology, Institut Curie, Paris (France); Laki, Fatima [Department of Surgical Oncology, Institut Curie, Paris (France); Beuzeboc, Philippe [Department of Medical Oncology, Institut Curie, Paris (France); Lefeuvre, Delphine [Department of Biostatistics, Institut Curie, Paris (France); Fournier-Bidoz, Nathalie; Kirova, Youlia M. [Department of Radiation Oncology, Institut Curie, Paris (France)

    2017-05-01

    Purpose: To evaluate locoregional control and survival after mastectomy, as well as toxicity, in patients irradiated by a previously described postmastectomy highly conformal electron beam radiation therapy technique (PMERT). Methods and Materials: We included all women irradiated by postmastectomy electron beam radiation therapy for nonmetastatic breast cancer between 2007 and 2011 in our department. Acute and late toxicities were retrospectively assessed using Common Terminology Criteria for Adverse Events version 3.0 criteria. Results: Among the 796 women included, 10.1% were triple-negative, 18.8% HER2-positive, and 24.6% received neoadjuvant chemotherapy (CT). Multifocal lesions were observed in 51.3% of women, and 64.6% had at least 1 involved lymph node (LN). Internal mammary chain, supraclavicular, infraclavicular, and axillary LNs were treated in 85.6%, 88.3%, 77.9%, and 14.9% of cases, respectively. With a median follow-up of 64 months (range, 6-102 months), 5-year locoregional recurrence–free survival and overall survival were 90% (95% confidence interval 88.1%-92.4%) and 90.9% (95% confidence interval 88.9%-93%), respectively. Early skin toxicity was scored as grade 1 in 58.5% of patients, grade 2 in 35.9%, and grade 3 in 4.5%. Concomitant CT was associated with increased grade 3 toxicity (P<.001). At long-term follow-up, 29.8% of patients presented temporary or permanent hyperpigmentation or telangiectasia or fibrosis (grade 1: 23.6%; grade 2: 5.2%; grade 3: 1%), with higher rates among smokers (P=.06); 274 patients (34.4%) underwent breast reconstruction. Only 24 patients (3%) had early esophagitis of grade 1. Only 3 patients developed ischemic heart disease: all had been treated by anthracycline-based CT with or without trastuzumab, all had been irradiated to the left chest wall and LN, and all presented numerous cardiovascular risk factors (2-4 factors). Conclusions: This study demonstrated the good efficacy of this technique in terms of

  8. Conformal radiotherapy: principles and classification

    International Nuclear Information System (INIS)

    Rosenwald, J.C.; Gaboriaud, G.; Pontvert, D.

    1999-01-01

    'Conformal radiotherapy' is the name fixed by usage and given to a new form of radiotherapy resulting from the technological improvements observed during the last ten years. While this terminology is now widely used, no precise definition can be found in the literature. Conformal radiotherapy refers to an approach in which the dose distribution is more closely 'conformed' or adapted to the actual shape of the target volume. However, the achievement of a consensus on a more specific definition is hampered by various difficulties, namely in characterizing the degree of 'conformality'. We have therefore suggested a classification scheme be established on the basis of the tools and the procedures actually used for all steps of the process, i.e., from prescription to treatment completion. Our classification consists of four levels: schematically, at level 0, there is no conformation (rectangular fields); at level 1, a simple conformation takes place, on the basis of conventional 2D imaging; at level 2, a 3D reconstruction of the structures is used for a more accurate conformation; and level 3 includes research and advanced dynamic techniques. We have used our personal experience, contacts with colleagues and data from the literature to analyze all the steps of the planning process, and to define the tools and procedures relevant to a given level. The corresponding tables have been discussed and approved at the European level within the Dynarad concerted action. It is proposed that the term 'conformal radiotherapy' be restricted to procedures where all steps are at least at level 2. (author)

  9. Stereotactic Ablative Body Radiation Therapy for Primary Kidney Cancer: A 3-Dimensional Conformal Technique Associated With Low Rates of Early Toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Daniel, E-mail: daniel.pham@petermac.org [Department of Radiotherapy Services, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Department of Medical Imaging and Radiation Sciences, Monash University, Melbourne, Victoria (Australia); Thompson, Ann [Department of Radiotherapy Services, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Kron, Tomas [Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Sir Peter MacCallum Department of Oncology, Melbourne University, Melbourne, Victoria (Australia); Foroudi, Farshad [Sir Peter MacCallum Department of Oncology, Melbourne University, Melbourne, Victoria (Australia); Department of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Kolsky, Michal Schneider [Department of Medical Imaging and Radiation Sciences, Monash University, Melbourne, Victoria (Australia); Devereux, Thomas; Lim, Andrew [Department of Radiotherapy Services, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Siva, Shankar [Sir Peter MacCallum Department of Oncology, Melbourne University, Melbourne, Victoria (Australia); Department of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia)

    2014-12-01

    Purpose: To describe our 3-dimensional conformal planning approaches and report early toxicities with stereotactic body radiation therapy for the management of primary renal cell carcinoma. Methods and Materials: This is an analysis of a phase 1 trial of stereotactic body radiation therapy for primary inoperable renal cell carcinoma. A dose of 42 Gy/3 fractions was prescribed to targets ≥5 cm, whereas for <5 cm 26 Gy/1 fraction was used. All patients underwent a planning 4-dimensional CT to generate a planning target volume (PTV) from a 5-mm isotropic expansion of the internal target volume. Planning required a minimum of 8 fields prescribing to the minimum isodose surrounding the PTV. Intermediate dose spillage at 50% of the prescription dose (R50%) was measured to describe the dose gradient. Early toxicity (<6 months) was scored using the Common Terminology Criteria for Adverse Events (v4.0). Results: From July 2012 to August 2013 a total of 20 patients (median age, 77 years) were recruited into a prospective clinical trial. Eleven patients underwent fractionated treatment and 9 patients a single fraction. For PTV targets <100 cm{sup 3} the median number of beams used was 8 (2 noncoplanar) to achieve an average R50% of 3.7. For PTV targets >100 cm{sup 3} the median beam number used was 10 (4 noncoplanar) for an average R50% value of 4.3. The R50% was inversely proportional to decreasing PTV volume (r=−0.62, P=.003) and increasing total beams used (r=−0.51, P=.022). Twelve of 20 patients (60%) suffered grade ≤2 early toxicity, whereas 8 of 20 patients (40%) were asymptomatic. Nausea, chest wall pain, and fatigue were the most common toxicities reported. Conclusion: A 3-dimensional conformal planning technique of 8-10 beams can be used to deliver highly tolerable stereotactic ablation to primary kidney targets with minimal early toxicities. Ongoing follow-up is currently in place to assess long-term toxicities and cancer control.

  10. Treatment of critical lower limb ischemia using a hybrid technique

    Directory of Open Access Journals (Sweden)

    Ricardo Wagner da Costa Moreira

    2014-09-01

    Full Text Available Critical ischemia of a lower limb is a condition that threatens its viability and must be treated promptly to avoid major amputation. Revascularization is the most effective treatment method and is performed using surgical or endovascular techniques. For patients with thoracoabdominal aortic aneurysms, combining these two approaches into a "hybrid technique" makes it possible to treat patients who could not be adequately treated by either technique in isolation. We report on a case of lower limb critical ischemia treated using a combination of surgery and endovascular techniques, in an application of the hybrid technique in a different arterial bed.

  11. Brine treatment, smoking and storage techniques: their effects on the ...

    African Journals Online (AJOL)

    Journal of Food Technology in Africa ... Brine treatment, smoking and storage techniques: their effects on the microbial quality of smoked mackerel. ... off odour development, softening of the fish and positively affected personal preference.

  12. Dose Escalation for Prostate Cancer Using the Three-Dimensional Conformal Dynamic Arc Technique: Analysis of 542 Consecutive Patients

    International Nuclear Information System (INIS)

    Jereczek-Fossa, Barbara A.; Vavassori, Andrea; Fodor, Cristiana; Santoro, Luigi; Zerini, Dario; Cattani, Federica; Garibaldi, Cristina; Cambria, Raffaella; Fodor, Andrei; Boboc, Genoveva Ionela; Vitolo, Viviana; Ivaldi, Giovanni Battista; Musi, Gennaro; De Cobelli, Ottavio; Orecchia, Roberto

    2008-01-01

    Purpose: To present the results of dose escalation using three-dimensional conformal dynamic arc radiotherapy (3D-ART) for prostate cancer. Methods and Materials: Five hundred and forty two T1-T3N0M0 prostate cancer patients were treated with 3D-ART. Dose escalation (from 76 Gy/38 fractions to 80 Gy/40 fractions) was introduced in September 2003; 32% of patients received 80 Gy. In 366 patients, androgen deprivation was added to 3D-ART. Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria and Houston definition (nadir + 2) were used for toxicity and biochemical failure evaluation, respectively. Median follow-up was 25 months. Results: Acute toxicity included rectal (G1-2 28.9%; G3 0.5%) and urinary events (G1-2 57.9%; G3-4 2.4%). Late toxicity included rectal (G1-2 15.8%; G3-4 3.1%) and urinary events (G1-2 26.9%; G3-4 1.6%). Two-year failure-free survival and overall survival rates were 94.1% and 97.9%, respectively. Poor prognostic group (GS, iPSA, T), transurethral prostate resection, and dose >76 Gy showed significant association to high risk of progression in multivariate analysis (p = 0.014, p = 0.045, and p 0.04, respectively). The negative effect of dose >76 Gy was not observed (p 0.10), when the analysis was limited to 353 patients treated after September 2003 (when dose escalation was introduced). Higher dose was not associated with higher late toxicity. Conclusions: Three-dimensional-ART is a feasible modality allowing for dose escalation (no increase in toxicity has been observed with higher doses). However, the dose increase from 76 to 80 Gy was not associated with better tumor outcome. Further investigation is warranted for better understanding of the dose effect for prostate cancer

  13. Inner tubing technique used for the treatment of anastomotic aneurism.

    Science.gov (United States)

    Gaspar, Márcio Teodoro da Costa; de Mattos, Bruno Vinicius Hortences; Sofia, Milena Cristina Dias; Mulatti, Grace Carvajal; Lederman, Alex

    2016-01-01

    The authors report the case of a 66-year-old male patient diagnosed with a pseudoaneurysm of the distal aorto-aortic anastomosis treated with the inner tubing technique. The patient had been operated on 1 year before when he had an aortic prosthesis implanted as treatment for a ruptured abdominal aortic aneurysm. The inner tubing technique was developed to facilitate the treatment in bifurcated vascular lesions, where endovascular conventional prosthesis is not available.

  14. [Plastic surgery treatment techniques for interdisciplinary therapy of pressure sores].

    Science.gov (United States)

    Müller, Karin; Becker, Frederic; Pfau, Matthias; Werdin, Frank

    2017-06-01

    Pressure sores in geriatric patients represent a challenge for all disciplines involved in the treatment process; however, the prerequisite for successful treatment is the elaboration of an interdisciplinary treatment concept. The treatment goals should be adapted to the individual needs of the patients including the life situation, general condition and local findings. In addition to general basic operative techniques, such as wound cleansing and conditioning, plastic and reconstructive surgery provides a wide range of highly specialized operative techniques for the treatment of these patients by which a definitive defect coverage can be achieved. The aim of this article is to raise awareness for these complex and highly specialized procedures for all disciplines participating in the treatment in order to improve the interdisciplinary cooperation and ultimately the quality of treatment.

  15. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC: A direct comparison of PET-based treatment planning.

    Science.gov (United States)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Rübe, Christian

    2016-02-01

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels.

  16. Impact of geometric uncertainties on evaluation of treatment techniques for prostate cancer

    International Nuclear Information System (INIS)

    Craig, Tim; Wong, Eugene; Bauman, Glenn; Battista, Jerry; Van Dyk, Jake

    2005-01-01

    Purpose: To assess the impact of patient repositioning and internal organ motion on prostate treatment plans using three-dimensional conformal and intensity-modulated radiotherapy. Methods and materials: Four-field, six-field, and simplified intensity-modulated arc therapy plans were generated for 5 prostate cancer patients. The planning target volume was created by adding a 1-cm margin to the clinical target volume. A convolution model was used to estimate the effect of random geometric uncertainties during treatment. Dose statistics, tumor control probabilities, and normal tissue complication probabilities were compared with and without the presence of uncertainty. The impact of systematic uncertainties was also investigated. Results: Compared with the planned treatments, the delivered dose distribution with random geometric uncertainties displayed an increase in the apparent minimal dose to the prostate and seminal vesicles and a decrease in the rectal volume receiving a high dose. This increased the tumor control probabilities and decreased the normal tissue complication probabilities. Changes were seen in the percentage of prostate volume receiving 100% and 95% of the prescribed dose, and the minimal dose and tumor control probabilities for the target volume. In addition, the volume receiving at least 65 Gy, the minimal dose, and normal tissue complication probabilities changed considerably for the rectum. The simplified intensity-modulated arc therapy technique was the most sensitive to systematic errors, especially in the anterior-posterior and superior-inferior directions. Conclusion: Geometric uncertainties should be considered when evaluating treatment plans. Contrary to the widely held belief, increased conformation of the dose distribution is not always associated with increased sensitivity to random geometric uncertainties if a sufficient planning target volume margin is used. Systematic errors may have a variable effect, depending on the treatment

  17. Dosimetric and Radiobiologic Comparison of 3D Conformal Versus Intensity Modulated Planning Techniques for Prostate Bed Radiotherapy

    International Nuclear Information System (INIS)

    Koontz, Bridget F.; Das, Shiva; Temple, Kathy; Bynum, Sigrun; Catalano, Suzanne; Koontz, Jason I.; Montana, Gustavo S.; Oleson, James R.

    2009-01-01

    Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

  18. Dosimetric and radiobiologic comparison of 3D conformal versus intensity modulated planning techniques for prostate bed radiotherapy.

    Science.gov (United States)

    Koontz, Bridget F; Das, Shiva; Temple, Kathy; Bynum, Sigrun; Catalano, Suzanne; Koontz, Jason I; Montana, Gustavo S; Oleson, James R

    2009-01-01

    Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

  19. The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer

    International Nuclear Information System (INIS)

    Wu, Q. Jackie; Thongphiew, Danthai; Wang Zhiheng; Chankong, Vira; Yin Fangfang

    2008-01-01

    Stereotactic body radiation therapy (SBRT), which delivers a much higher fractional dose than conventional treatment in only a few fractions, is an effective treatment for liver metastases. For patients who are treated under free-breathing conditions, however, respiration-induced tumor motion in the liver is a concern. Limited clinical information is available related to the impact of tumor motion and treatment technique on the dosimetric consequences. This study evaluated the dosimetric deviations between planned and delivered SBRT dose in the presence of tumor motion for three delivery techniques: three-dimensional conformal static beams (3DCRT), dynamic conformal arc (DARC), and intensity-modulated radiation therapy (IMRT). Five cases treated with SBRT for liver metastases were included in the study, with tumor motions ranging from 0.5 to 1.75 cm. For each case, three different treatment plans were developed using 3DCRT, DARC, and IMRT. The gantry/multileaf collimator (MLC) motion in the DARC plans and the MLC motion in the IMRT plans were synchronized to the patient's respiratory motion. Retrospectively sorted four-dimensional computed tomography image sets were used to determine patient-organ motion and to calculate the dose delivered during each respiratory phase. Deformable registration, using thin-plate-spline models, was performed to encode the tumor motion and deformation and to register the dose-per-phase to the reference phase images. The different dose distributions resulting from the different delivery techniques and motion ranges were compared to assess the effect of organ motion on dose delivery. Voxel dose variations occurred mostly in the high gradient regions, typically between the target volume and normal tissues, with a maximum variation up to 20%. The greatest CTV variation of all the plans was seen in the IMRT technique with the largest motion range (D99: -8.9%, D95: -8.3%, and D90: -6.3%). The greatest variation for all 3DCRT plans was less

  20. Technique of treatment of prostatic cancer with scarcity means

    International Nuclear Information System (INIS)

    Velazquez M, S.; Carrera M, F.; Gomez- Millan B, J.; Gutierrez B, L.; Bayo L, E.

    1998-01-01

    To show the particularities in the treatment simulation-localization, in the volume delimitation and in the main planning strategies motive by our scarcity means during the first year of performance (absence of physical simulator, planning system 2D). It was utilized a computerized tomograph, an X-ray equipment with tele commanded table and another with ceiling telescopic suspension. Also it was utilized a radio opaque lattice of marked center and knowing space and also a magnetic pointer for indicating 80 cm length between focus-skin. In the CT it was took spaced cuts starting from the central, at coincident distances with lattice lines, contouring the clinical target volume (CTV), what subsequently it was removed to the simulation plate. The volume to be irradiated, or PTV (planning target volume), it was determined adding a margin to CTV. The irradiation to itself it was realized with a minimum of 3 fields in the first phase. From 16 patients evaluated, the 100 % normalize the PSA ciphers at 6 months. 25 % patients, rectal-intestinal toxicity grade 1 and 18.7 % grade 2. Acute vesicle toxicity grade 1 in a 31.2 % patients, grade 2 in 12.5 % and grade 3 in 6.5 %. A 25 % patients presented dermatitis grade 1 and 18 % grade 2 and grade 3. Under no case it was necessary the treatment interruption for the toxicity normalization. Maximum local control with absence of chronic toxicity. The low toxicity presented could must be to the utilization of conformations in the lateral plates. According to our experience, we believe that it is not necessary to renounce at this type of treatments if it is lacking of high energies, such as succeed in some installations if it is utilized 3 or more fields in the first phase and individualized conformations. (Author)

  1. Conformal technique dose escalation in prostate cancer: improved cancer control with higher doses in patients with pretreatment PSA {>=} 10 ngm/ml

    Energy Technology Data Exchange (ETDEWEB)

    Hanks, G E; Lee, W R; Hanlon, A L; Kaplan, E; Epstein, B; Schultheiss, T

    1995-07-01

    Purpose: Single institutions and an NCI supported group of institutions have been investigating the value of dose escalation in patients with prostate cancer treated by conformal treatment techniques. Improvement in morbidity has been previously established, while this report identifies the pretreatment PSA level subgroups of patients who benefitted in cancer control from higher dose. Materials and Methods: We report actuarial bNED survival rates for 375 consecutive patients with known pretreatment PSA levels treated with conformal technique between 5/89 and 12/93. The whole pelvis was treated to 45 Gy in 25 fractions in all T2C,3, all Gleason 8, 9, 10 and all patients with pretreatment PSA {>=}20. The prostate {+-} seminal vesicles was boosted at 2.1 Gy/day to the center of the prostate to 65-79 Gy (65-69 N=50), 70-72.49 N=94, 72.5-74.9 N=82, 75-77.49 N=129 and {>=}77.5 N=20). The median followup is 21 mos with a range of 3 to 67 mos. The highest dose patients have the least followup, reducing the impact of the highest dose levels at this time. Patients are analyzed for the entire group divided at 71 Gy and at 73 Gy calculated at the center of the prostate. Each dose group is then subdivided by pretreatment PSA levels <10, 10-19.9, and {>=}20 ngm/ml and dose levels are compared within pretreatment PSA level group. bNED failure is defined as PSA {>=}1.5 ngm/ml and rising on two consecutive values. Results: Table 1 shows the bNED survival rates at 24 and 36 mos for all patients and the three pretreatment PSA level groups. For all patients pooled, there is an overall advantage to using doses {>=}71 Gy (64% vs 85% at 36 mo, p=.006) and {>=}73 Gy (71% vs 86% at 36 mo, p=.07). The subgroup of PSA <10 ngm/ml, however, shows no benefit in bNED survival when using doses over 71 Gy (90% vs 93% at 36 mo) or 73 Gy (91 vs 94% at 36 mo). The subgroup PSA 10 ngm/ml to 19.9 ngm/ml shows improved cancer control when using doses over 71 Gy (61% vs 88% at 36 mo, p=.03) and over 73

  2. Conformal Nets II: Conformal Blocks

    Science.gov (United States)

    Bartels, Arthur; Douglas, Christopher L.; Henriques, André

    2017-08-01

    Conformal nets provide a mathematical formalism for conformal field theory. Associated to a conformal net with finite index, we give a construction of the `bundle of conformal blocks', a representation of the mapping class groupoid of closed topological surfaces into the category of finite-dimensional projective Hilbert spaces. We also construct infinite-dimensional spaces of conformal blocks for topological surfaces with smooth boundary. We prove that the conformal blocks satisfy a factorization formula for gluing surfaces along circles, and an analogous formula for gluing surfaces along intervals. We use this interval factorization property to give a new proof of the modularity of the category of representations of a conformal net.

  3. Conformal transformations in superspace

    International Nuclear Information System (INIS)

    Dao Vong Duc

    1977-01-01

    The spinor extension of the conformal algebra is investigated. The transformation law of superfields under the conformal coordinate inversion R defined in the superspace is derived. Using R-technique, the superconformally covariant two-point and three-point correlation functions are found

  4. Relation between the treated region of the patient with ca. of the uterine cervix and her body-type in whole pelvis irradiation with conformation technique

    International Nuclear Information System (INIS)

    Morita, Kozo; Kakehi, Masae

    1975-01-01

    In whole pelvis irradiation using the conformation technique for the patient with carcinoma of the uterine cervix, standardization of the shape of the treated region was tried on the basis of measuring the pelvis in X-ray films. This was done on the X-rays of 200 patients with carcinoma of the uterine cervix. The body-type of the patient the most remarkably influenced the shape of the treated region. Ten clinical types of cam-group (treated region) were determined, in order to perform conformation radiotherapy for carcinoma of the uterine cervix. Although the shape of the treated region could also be changed by the invasion of the lesion, the position of the portio and the general condition of the patients, these 10 standard types of cam-group can be applied practically to almost all of the patients. (Evans, J.)

  5. The feasibility of using Pareto fronts for comparison of treatment planning systems and delivery techniques

    International Nuclear Information System (INIS)

    Ottosson, Rickard O.; Sjoestroem, David; Behrens, Claus F.; Karlsson, Anna; Engstroem, Per E.; Knoeoes, Tommy; Ceberg, Crister

    2009-01-01

    Pareto optimality is a concept that formalises the trade-off between a given set of mutually contradicting objectives. A solution is said to be Pareto optimal when it is not possible to improve one objective without deteriorating at least one of the other. A set of Pareto optimal solutions constitute the Pareto front. The Pareto concept applies well to the inverse planning process, which involves inherently contradictory objectives, high and uniform target dose on one hand, and sparing of surrounding tissue and nearby organs at risk (OAR) on the other. Due to the specific characteristics of a treatment planning system (TPS), treatment strategy or delivery technique, Pareto fronts for a given case are likely to differ. The aim of this study was to investigate the feasibility of using Pareto fronts as a comparative tool for TPSs, treatment strategies and delivery techniques. In order to sample Pareto fronts, multiple treatment plans with varying target conformity and dose sparing of OAR were created for a number of prostate and head and neck IMRT cases. The DVHs of each plan were evaluated with respect to target coverage and dose to relevant OAR. Pareto fronts were successfully created for all studied cases. The results did indeed follow the definition of the Pareto concept, i.e. dose sparing of the OAR could not be improved without target coverage being impaired or vice versa. Furthermore, various treatment techniques resulted in distinguished and well separated Pareto fronts. Pareto fronts may be used to evaluate a number of parameters within radiotherapy. Examples are TPS optimization algorithms, the variation between accelerators or delivery techniques and the degradation of a plan during the treatment planning process. The issue of designing a model for unbiased comparison of parameters with such large inherent discrepancies, e.g. different TPSs, is problematic and should be carefully considered

  6. The feasibility of using Pareto fronts for comparison of treatment planning systems and delivery techniques.

    Science.gov (United States)

    Ottosson, Rickard O; Engstrom, Per E; Sjöström, David; Behrens, Claus F; Karlsson, Anna; Knöös, Tommy; Ceberg, Crister

    2009-01-01

    Pareto optimality is a concept that formalises the trade-off between a given set of mutually contradicting objectives. A solution is said to be Pareto optimal when it is not possible to improve one objective without deteriorating at least one of the other. A set of Pareto optimal solutions constitute the Pareto front. The Pareto concept applies well to the inverse planning process, which involves inherently contradictory objectives, high and uniform target dose on one hand, and sparing of surrounding tissue and nearby organs at risk (OAR) on the other. Due to the specific characteristics of a treatment planning system (TPS), treatment strategy or delivery technique, Pareto fronts for a given case are likely to differ. The aim of this study was to investigate the feasibility of using Pareto fronts as a comparative tool for TPSs, treatment strategies and delivery techniques. In order to sample Pareto fronts, multiple treatment plans with varying target conformity and dose sparing of OAR were created for a number of prostate and head & neck IMRT cases. The DVHs of each plan were evaluated with respect to target coverage and dose to relevant OAR. Pareto fronts were successfully created for all studied cases. The results did indeed follow the definition of the Pareto concept, i.e. dose sparing of the OAR could not be improved without target coverage being impaired or vice versa. Furthermore, various treatment techniques resulted in distinguished and well separated Pareto fronts. Pareto fronts may be used to evaluate a number of parameters within radiotherapy. Examples are TPS optimization algorithms, the variation between accelerators or delivery techniques and the degradation of a plan during the treatment planning process. The issue of designing a model for unbiased comparison of parameters with such large inherent discrepancies, e.g. different TPSs, is problematic and should be carefully considered.

  7. Dosimetric comparison between VMAT and RC3D techniques: case of prostate treatment

    Science.gov (United States)

    Chemingui, Fatima Zohra; Benrachi, Fatima; Bali, Mohamed Saleh; Ladjal, Hamid

    2017-09-01

    Considered as the second men cancer in Algeria, prostate cancer is treated in 70% by radiation. That's why radiation therapy is therapeutic weapon for prostate cancer. Conformational Radiotherapy in 3D is the most common technique [1-5]. The use of conventionally optimized treatment plans was compared at case scenario of optimized treatment plans VMAT for prostate cancer. The evaluation of the two optimizations strategies focused on the resulting plans ability to retain dose objectives under the influence of patient set up. Dose Volume Histogram in the Planning Target Volume and dose in the Organs At Risks were used to calculate the conformity index, and evaluation ratio of irradiated volume which represent the main tool of comparison [6,7]. The situation was analysed systematically. The 14% dose increase in the target leads to a decrease in the dose in adjacent organs with 39% in the bladder. Therefore, the criterion for better efficacy and less toxicity reveal that VMAT is the best choice.

  8. Dosimetric comparison between VMAT and RC3D techniques: case of prostate treatment

    Directory of Open Access Journals (Sweden)

    Chemingui Fatima Zohra

    2017-01-01

    Full Text Available Considered as the second men cancer in Algeria, prostate cancer is treated in 70% by radiation. That's why radiation therapy is therapeutic weapon for prostate cancer. Conformational Radiotherapy in 3D is the most common technique [1−5]. The use of conventionally optimized treatment plans was compared at case scenario of optimized treatment plans VMAT for prostate cancer. The evaluation of the two optimizations strategies focused on the resulting plans ability to retain dose objectives under the influence of patient set up. Dose Volume Histogram in the Planning Target Volume and dose in the Organs At Risks were used to calculate the conformity index, and evaluation ratio of irradiated volume which represent the main tool of comparison [6,7]. The situation was analysed systematically. The 14% dose increase in the target leads to a decrease in the dose in adjacent organs with 39% in the bladder. Therefore, the criterion for better efficacy and less toxicity reveal that VMAT is the best choice.

  9. Open table-top device positioning technique to reduce small bowel obstruction. Positioning accuracy and impact on conformal radiation therapy techniques; Lochbrettechnik zur Duenndarmschonung. Untersuchungen zur Lagerungsgenauigkeit unter Beruecksichtigung konformierender Bestrahlungstechniken

    Energy Technology Data Exchange (ETDEWEB)

    Rudat, V. [Abteilung Strahlentherapie, Klinische Radiologie, Universitaetsklinikum Heidelberg (Germany); Flentje, M. [Abteilung Strahlentherapie, Klinische Radiologie, Universitaetsklinikum Heidelberg (Germany); Engenhart, R. [Abteilung Strahlentherapie, Klinische Radiologie, Universitaetsklinikum Heidelberg (Germany); Metzger, M. [Abteilung Strahlentherapie, Klinische Radiologie, Universitaetsklinikum Heidelberg (Germany); Wannenmacher, M. [Abteilung Strahlentherapie, Klinische Radiologie, Universitaetsklinikum Heidelberg (Germany)

    1995-08-01

    The immobilization error of patients positioned on the opern table-top device in prone prosition as well as the movement of the small bowel out of the pelvis by this positioning technique was determined. The positioning error is of special importance for the 3-dimensional treatment planning for conformal radiotherapy. The positioning error was determined by superposing 106 portal films with the corresponding simultor films from 21 patients with carcinoma of the rectum who received 3D-planned conformal radiotherapy (o-field technique with irregular blocks). The movement of the small bowel out of the pelvis was studied by comparing simulator films after barium swallow in supine and open table-top position as well with 3D-treatment plans of the same patient in both positions in 3 cases. The positioning error along the medio-lateral, dorso-ventral und cranio-caudal axis was 1.4/-0.6/1.8 mm and the standard deviation 4.4/6.8/6.3 mm, respectively. In comparison to the supine position more rotation errors in the sagittal view were observed (37% and 9% respectively) with a media of 5.1 . Six out of 22 patients showed no adhesions of the small bowel and a complete movement out of the tratment field was achieved. 14 out of 16 Patients with adhesions revealed a partial movement of the small bowel out of the treatment field. Comparing 3D-treatment plans in both positions again demonstrated a marked reduction of the irradiated small bowel volume with the use of the open table-top decive. (orig.) [Deutsch] Die Anwendung der Lochbrettechnik sowie konformierender Bestrahlungstechnik laesst eine Verminderung der Duenndarmbelastung bei der Bestrahlung pelviner Tumoren erwarten. Die Lagerungsgenauigkeit der Patienten als wichtiger Gesichtspunkt bei der dreidimensionalen Bestrahlungsplanung wurde bestimmt und die Duenndarmverlagerung aus dem Bestrahlungsfeld bei der Patientenlagerung im Lochbrett untersucht. Saemtliche zu untersuchende Patienten erhielten eine dreidimensional geplante

  10. A comparison of different three-dimensional treatment planning techniques for localized radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Koswig, S.; Dinges, S.; Buchali, A.; Boehmer, D.; Salk, J.; Rosenthal, P.; Harder, C.; Schlenger, L.; Budach, V.

    1999-01-01

    Purpose: Four different three-dimensional planning techniques for localized radiotherapy of prostate cancer were compared with regard to dose homogeneity within the target volume and dose to organs at risk, dependent upon tumor stage. Patients and Methods: Six patients with stage T1, 7 patients with stage T2 and 4 patients with stage T3 were included in this study. Four different 3D treatment plans (rotation, 4-field, 5-field and 6-field technique) were calculated for each patient. Dose was calculated with the reference point at the isocenter (100%). The planning target volume was encompassed within the 95% isodose surface. All the techniques used different shaped portal for each beam. Dose volume histograms were created and compared for the planning target volume and the organs at risk (33%, 50%, 66% volume level) in all techniques. Results: The 4 different three-dimensional planning techniques revealed no differences concerning dose homogeneity within the planning target volume. The dose volume distribution at organs at risk show differences between the calculated techniques. In our study the best protection for bladder and rectum in stage T1 and T2 was achieved by the 6-field technique. A significant difference was achieved between 6-field and 4-field technique only in the 50% volume of the bladder (p=0.034), between the 6-field and rotation technique (all volume levels) and between 5-field and rotation technique (all volume levels). In stage T1, T2 6-field and 4-field technique in 50% (p-0.033) and 66% (p=0.011) of the rectum volume. In stage T3 a significant difference was not observed between the 4 techniques. The best protection of head of the femur was achieved by the rotation technique. Conclusion: In the localized radiotherapy of prostate cancer in stage T1 or T2 the best protection for bladder and rectum was achieved by a 3D-planned conformal 6-field technique. If the seminal vesicles have been included in the target volume and in the case of large

  11. Surgical techniques for treatment of gastroesophageal reflux disease

    Directory of Open Access Journals (Sweden)

    Carlos Édder de Mello Cardoso Lima

    2015-12-01

    Full Text Available Gastroesophageal reflux is one of the most frequently gastrointestinal tract diseases currently found, having a great impact on the patient's quality of life. Purpose: to analyze the main surgical techniques used in the treatment of this pathology, their indications, advantages and disadvantages. Methods: this is a literature review. Thirteen articles published between 1998 and 2013 in the Lilacs, Bireme e Scielo databases, addressing different surgical techniques for the treatment of gastroesophageal reflux were selected. Results: Five hundred and thirty-eight total fundoplications and 466 partial fundoplications were performed. Conclusion: The findings of this review show that total fundoplication is the most commonly used technique in the treatment of gastroesophageal reflux disease.

  12. A study on quantitative analysis of field size and dose by using gating system in 4D conformal radiation treatment

    Science.gov (United States)

    Ji, Youn-Sang; Dong, Kyung-Rae; Kim, Chang-Bok; Chung, Woon-Kwan; Cho, Jae-Hwan; Lee, Hae-Kag

    2012-10-01

    This study evaluated the gating-based 4-D conformal radiation therapy (4D-CT) treatment planning by a comparison with the common 3-D conformal radiation therapy (3D-CT) treatment planning and examined the change in treatment field size and dose to the tumors and adjacent normal tissues because an unnecessary dose is also included in the 3-D treatment planning for the radiation treatment of tumors in the chest and abdomen. The 3D-CT and gating-based 4D-CT images were obtained from patients who had undergone radiation treatment for chest and abdomen tumors in the oncology department. After establishing a treatment plan, the CT treatment and planning system were used to measure the change in field size for analysis. A dose volume histogram (DVH) was used to calculate the appropriate dose to planning target volume (PTV) tumors and adjacent normal tissue. The difference in the treatment volume of the chest was 0.6 and 0.83 cm on the X- and Y-axis, respectively, for the gross tumor volume (GTV). Accordingly, the values in the 4D-CT treatment planning were smaller and the dose was more concentrated by 2.7% and 0.9% on the GTV and clinical target volume (CTV), respectively. The normal tissues in the surrounding normal tissues were reduced by 3.0%, 7.2%, 0.4%, 1.7%, 2.6% and 0.2% in the bronchus, chest wall, esophagus, heart, lung and spinal cord, respectively. The difference in the treatment volume of the abdomen was 0.72 cm on the X-axis and 0.51 cm on the Y-axis for the GTV; and 1.06 cm on the X-axis and 1.85 cm on the Y-axis for the PTV. Therefore, the values in the 4D-CT treatment planning were smaller. The dose was concentrated by 6.8% and 4.3% on the GTV and PTV, respectively, whereas the adjacent normal tissues in the cord, Lt. kidney, Rt. kidney, small bowels and whole liver were reduced by 3.2%, 4.2%, 1.5%, 6.2% and 12.7%, respectively. The treatment field size was smaller in volume in the case of the 4D-CT treatment planning. In the DVH, the 4D-CT treatment

  13. Conformal house

    DEFF Research Database (Denmark)

    Ryttov, Thomas Aaby; Sannino, Francesco

    2010-01-01

    fixed point. As a consistency check we recover the previously investigated bounds of the conformal windows when restricting to a single matter representation. The earlier conformal windows can be imagined to be part now of the new conformal house. We predict the nonperturbative anomalous dimensions...... at the infrared fixed points. We further investigate the effects of adding mass terms to the condensates on the conformal house chiral dynamics and construct the simplest instanton induced effective Lagrangian terms...

  14. The evolution of rectal and urinary toxicity and immune response in prostate cancer patients treated with two three-dimensional conformal radiotherapy techniques

    International Nuclear Information System (INIS)

    Vranova, Jana; Vinakurau, Stepan; Richter, Jan; Starec, Miroslav; Fiserova, Anna; Rosina, Jozef

    2011-01-01

    Our research compared whole pelvic (WP) and prostate-only (PO) 3-dimensional conformal radiotherapy (3DCRT) techniques in terms of the incidence and evolution of acute and late toxicity of the rectum and urinary bladder, and identified the PTV-parameters influencing these damages and changes in antitumor immune response. We analyzed 197 prostate cancer patients undergoing 3DCRT for gastrointestinal (GI) and genitourinary (GU) toxicities, and conducted a pilot immunological study including flow cytometry and an NK cell cytotoxicity assay. Acute and late toxicities were recorded according to the RTOG and the LENT-SOMA scales, respectively. Univariate and multivariate analyses were conducted for factors associated with toxicity. In the WP group, an increase of acute rectal toxicity was observed. A higher incidence of late GI/GU toxicity appeared in the PO group. Only 18 patients (WP-7.76% and PO-11.11%) suffered severe late GI toxicity, and 26 patients (WP-11.21% and PO-16.05%) severe late GU toxicity. In the majority of acute toxicity suffering patients, the diminution of late GI/GU toxicity to grade 1 or to no toxicity after radiotherapy was observed. The 3DCRT technique itself, patient age, T stage of TNM classification, surgical intervention, and some dose-volume parameters emerged as important factors in the probability of developing acute and late GI/GU toxicity. The proportion and differentiation of NK cells positively correlated during 3DCRT and negatively so after its completion with dose-volumes of the rectum and urinary bladder. T and NKT cells were down-regulated throughout the whole period. We found a negative correlation between leukocyte numbers and bone marrow irradiated by 44-54 Gy and a positive one for NK cell proportion and doses of 5-25 Gy. The acute GU, late GU, and GI toxicities up-regulated the T cell (CTL) numbers and NK cytotoxicity. Our study demonstrates the association of acute and late damage of the urinary bladder and rectum, with

  15. Cost-Effectiveness Analysis of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Preoperative Treatment of Extremity Soft Tissue Sarcomas

    Energy Technology Data Exchange (ETDEWEB)

    Richard, Patrick, E-mail: patrjr@uw.edu [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Phillips, Mark; Smith, Wade [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Davidson, Darin [Department of Orthopedic Surgery, University of Washington, Seattle, Washington (United States); Kim, Edward; Kane, Gabrielle [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States)

    2016-07-01

    Purpose: Create a cost-effectiveness model comparing preoperative intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3DCRT) for extremity soft tissue sarcomas. Methods and Materials: Input parameters included 5-year local recurrence rates, rates of acute wound adverse events, and chronic toxicities (edema, fracture, joint stiffness, and fibrosis). Health-state utilities were used to calculate quality-adjusted life years (QALYs). Overall treatment costs per QALY or incremental cost-effectiveness ratio (ICER) were calculated. Roll-back analysis was performed using average costs and utilities to determine the baseline preferred radiation technique. One-way, 2-way, and probabilistic sensitivity analyses (PSA) were performed for input parameters with the largest impact on the ICER. Results: Overall treatment costs were $17,515.58 for 3DCRT compared with $22,920.51 for IMRT. The effectiveness was higher for IMRT (3.68 QALYs) than for 3DCRT (3.35 QALYs). The baseline ICER for IMRT was $16,842.75/QALY, making it the preferable treatment. The ICER was most sensitive to the probability of local recurrence, upfront radiation costs, local recurrence costs, certain utilities (no toxicity/no recurrence, grade 1 toxicity/no local recurrence, grade 4 toxicity/no local recurrence), and life expectancy. Dominance patterns emerged when the cost of 3DCRT exceeded $15,532.05 (IMRT dominates) or the life expectancy was under 1.68 years (3DCRT dominates). Furthermore, preference patterns changed based on the rate of local recurrence (threshold: 13%). The PSA results demonstrated that IMRT was the preferred cost-effective technique for 64% of trials compared with 36% for 3DCRT. Conclusions: Based on our model, IMRT is the preferred technique by lowering rates of local recurrence, severe toxicities, and improving QALYs. From a third-party payer perspective, IMRT should be a supported approach for extremity soft tissue sarcomas.

  16. Cost-Effectiveness Analysis of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Preoperative Treatment of Extremity Soft Tissue Sarcomas

    International Nuclear Information System (INIS)

    Richard, Patrick; Phillips, Mark; Smith, Wade; Davidson, Darin; Kim, Edward; Kane, Gabrielle

    2016-01-01

    Purpose: Create a cost-effectiveness model comparing preoperative intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3DCRT) for extremity soft tissue sarcomas. Methods and Materials: Input parameters included 5-year local recurrence rates, rates of acute wound adverse events, and chronic toxicities (edema, fracture, joint stiffness, and fibrosis). Health-state utilities were used to calculate quality-adjusted life years (QALYs). Overall treatment costs per QALY or incremental cost-effectiveness ratio (ICER) were calculated. Roll-back analysis was performed using average costs and utilities to determine the baseline preferred radiation technique. One-way, 2-way, and probabilistic sensitivity analyses (PSA) were performed for input parameters with the largest impact on the ICER. Results: Overall treatment costs were $17,515.58 for 3DCRT compared with $22,920.51 for IMRT. The effectiveness was higher for IMRT (3.68 QALYs) than for 3DCRT (3.35 QALYs). The baseline ICER for IMRT was $16,842.75/QALY, making it the preferable treatment. The ICER was most sensitive to the probability of local recurrence, upfront radiation costs, local recurrence costs, certain utilities (no toxicity/no recurrence, grade 1 toxicity/no local recurrence, grade 4 toxicity/no local recurrence), and life expectancy. Dominance patterns emerged when the cost of 3DCRT exceeded $15,532.05 (IMRT dominates) or the life expectancy was under 1.68 years (3DCRT dominates). Furthermore, preference patterns changed based on the rate of local recurrence (threshold: 13%). The PSA results demonstrated that IMRT was the preferred cost-effective technique for 64% of trials compared with 36% for 3DCRT. Conclusions: Based on our model, IMRT is the preferred technique by lowering rates of local recurrence, severe toxicities, and improving QALYs. From a third-party payer perspective, IMRT should be a supported approach for extremity soft tissue sarcomas.

  17. Design and implementation of a rotational radiotherapy technique for breast cancer treatment and their comparison with 3-D-Crt irradiation technique

    International Nuclear Information System (INIS)

    Gutierrez M, J. G.; Lopez V, A.; Rivera M, T.; Velazquez T, J. J.; Adame G, C. S.; Rubio N, O.; Chagoya G, A.; Hernandez G, J. C.

    2015-10-01

    Breast cancer is one of oncological diseases worldwide, as well in Mexico, which causes even more deaths than cervical cancer; this condition is the second death cause in women aged 30-54 years and threatens all socio-economic groups. The treatment is highly dependent on the stage which is detected and based on protocols that include a combination of surgery, chemotherapy and radiotherapy. This paper studies the main irradiation technique for patients with mastectomy, breast full cycle (irradiation of the chest well and supraclavicular nodes) in their mode Three Dimensional - Conformal Radiation Therapy (3-D-Crt), and compared with the Volumetric Modulated Arc Therapy (VMAT) technique proposed in this paper. In both techniques the prescription was 50 Gy divided into 25 fractions. The techniques were applied in three female patients (being an initial study) with disease of the left side, the target volume and organs at risk were delineated by the medical treating radiation oncologist, the planning system used was Eclipse version 10; for quantitative comparison of both plans indexes of homogeneity were used, con formality, the target volume coverage and normal tissue, sub factors and overdosing, the conformation number and coverage quality. They were evaluated and compared the media, maximum and minimum dose of the organs at risk, based on the fact that the coverage of the target volume, dose gradient and dose at risk organs are acceptable (prescription dose greater that 90% coverage, gradient less that 20% and organs at risk in accordance with the Quantec limitations for both versions). (Author)

  18. Treatment of MSW fly ashes using the electrodialytic remediation technique

    DEFF Research Database (Denmark)

    Ferreira, Celia; Ribeiro, Alexandra B.; Ottosen, Lisbeth M.

    2004-01-01

    In the present work the electrodialytic remediation technique is applied for the treatment of fly ash, a hazardous by-product resulting from the incineration of municipal solid waste. Results are presented for an experiment conducted for 40 days at 38 mA, with a continuously stirred cell. Experim......In the present work the electrodialytic remediation technique is applied for the treatment of fly ash, a hazardous by-product resulting from the incineration of municipal solid waste. Results are presented for an experiment conducted for 40 days at 38 mA, with a continuously stirred cell...

  19. Potential clinical efficacy of intensity-modulated conformal therapy

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Buatti, John M.; Bova, Francis J.; Friedman, William A.; Mendenhall, William M.; Zlotecki, Robert A.

    1998-01-01

    Purpose: The purpose of this study was to examine the potential benefit of using intensity-modulated conformal therapy for a variety of lesions currently treated with stereotactic radiosurgery or conventional radiotherapy. Methods and Materials: Intensity-modulated conformal treatment plans were generated for small intracranial lesions, as well as head and neck, lung, breast, and prostate cases, using the Peacock Plan[reg] treatment-planning system (Nomos Corporation). For small intracranial lesions, intensity-modulated conformal treatment plans were compared with stereotactic radiosurgery treatment plans generated for patient treatment at the University of Florida Shands Cancer Center. For other sites (head and neck, lung, breast, and prostate), plans generated using the Peacock Plan[reg] were compared with conventional treatment plans, as well as beam's-eye-view conformal treatment plans. Plan comparisons were accomplished through conventional qualitative review of two-dimensional (2D) dose distributions in conjunction with quantitative techniques, such as dose-volume histograms, dosimetric statistics, normal tissue complication probabilities, tumor control probabilities, and objective numerical scoring. Results: For small intracranial lesions, there is little difference between intensity-modulated conformal treatment planning and radiosurgery treatment planning in the conformation of high isodose lines with the target volume. However, stereotactic treatment planning provides a steeper dose gradient outside the target volume and, hence, a lower normal tissue toxicity index. For extracranial sites, objective numerical scores for beam's-eye-view and intensity-modulated conformal planning techniques are superior to scores for conventional treatment plans. The beam's-eye-view planning technique prevents geographic target misses and better excludes healthy tissues from the treatment portal. Compared with scores for the beam's-eye-view planning technique, scores for

  20. Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment

    Directory of Open Access Journals (Sweden)

    Bora Uysal

    2013-03-01

    Full Text Available Objective: The purpose of this dosimetric study is the targeted dose homogeneity and critical organ dose comparison of 7-field Intensity Modulated Radiotherapy (IMRT and 3-D 4-field conformal radiotherapy. Study Design: Cross sectional study. Material and Methods: Twenty patients with low and moderate risk prostate cancer treated at Gülhane Military Medical School Radiation Oncology Department between January 2009 and December 2009 are included in this study. Two seperate dosimetric plans both for 7-field IMRT and 3D-CRT have been generated for each patient to comparatively evaluate the dosimetric status of both techniques and all the patients received 7-field IMRT. Results: Dose-comparative evaluation of two techniques revealed the superiority of IMRT technique with statistically significantly lower femoral head doses along with reduced critical organ dose-volume parameters of bladder V60 (the volume receiving 60 Gy and rectal V40 (the volume receiving 40 Gy and V60. Conclusion: It can be concluded that IMRT is an effective definitive management tool for prostate cancer with improved critical organ sparing and excellent dose homogenization in target organs of prostate and seminal vesicles.

  1. Comparison of Radiation Treatment Plans for Breast Cancer between 3D Conformal in Prone and Supine Positions in Contrast to VMAT and IMRT Supine Positions

    Science.gov (United States)

    Bejarano Buele, Ana Isabel

    The treatment regimen for breast cancer patients typically involves Whole Breast Irradiation (WBI). The coverage and extent of the radiation treatment is dictated by location of tumor mass, breast tissue distribution, involvement of lymph nodes, and other factors. The current standard treatment approach used at our institution is a 3D tangential beam geometry, which involves two fields irradiating the breast, or a four field beam arrangement covering the whole breast and involved nodes, while decreasing the dose to organs as risk (OARs) such as the lung and heart. The coverage of these targets can be difficult to achieve in patients with unfavorable thoracic geometries, especially in those cases in which the planning target volume (PTV) is extended to the chest wall. It is a well-known fact that exposure of the heart to ionizing radiation has been proved to increase the subsequent rate of ischemic heart disease. In these cases, inverse planned treatments have become a proven alternative to the 3D approach. The goal of this research project is to evaluate the factors that affect our current techniques as well as to adapt the development of inverse modulated techniques for our clinic, in which breast cancer patients are one of the largest populations treated. For this purpose, a dosimetric comparison along with the evaluation of immobilization devices was necessary. Radiation treatment plans were designed and dosimetrically compared for 5 patients in both, supine and prone positions. For 8 patients, VMAT and IMRT plans were created and evaluated in the supine position. Skin flash incorporation for inverse modulated plans required measurement of the surface dose as well as an evaluation of breast volume changes during a treatment course. It was found that prone 3D conformal plans as well as the VMAT and IMRT plans are generally superior in sparing OARs to supine plans with comparable PTV coverage. Prone setup leads to larger shifts in breast volume as well as in

  2. Comparative study of the effects of treatment techniques on the ...

    African Journals Online (AJOL)

    This paper reports the effects of some fibre treatment techniques namely: mercerization, acetylation and semi-carbonisation on the performance of Kenaf fibres. The treated kenaf fibres which are considered biodegradable, cost effective, renewable and user friendly have been used as a possible base friction material for ...

  3. Development of dose audits for complex treatment techniques in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Stefanic, A. M.; Molina, L.; Vallejos, M.; Montano, G.; Zaretzky, A.; Saravi, M., E-mail: stefanic@cae.cnea.gov.ar [Centro Regional de Referencia con Patrones Secundarios para Dosimetria - CNEA, Presbitero Juan Gonzalez y Aragon 15, B1802AYA Ezeiza (Argentina)

    2014-08-15

    This work was performed in the frame of a Coordinated Research Project (CRP) with IAEA whose objective was to extend the scope of activities carried out by national TLD-based networks from dosimetry audit for rectangular radiation fields to irregular and small fields relevant to modern radiotherapy. External audit is a crucial element in QA programmes for clinical dosimetry in radiotherapy, therefore a methodology and procedures were developed and were made available for dose measurement of complex radiotherapy parameters used for cancer treatment. There were three audit steps involved in this CRP: TLD based dosimetry for irregular MLC fields for conformal radiotherapy, dosimetry in the presence of heterogeneities and 2D MLC shaped fields relevant to stereotactic radiotherapy and applicable to dosimetry for IMRT. In addition, a new development of film-based 2D dosimetry for testing dose distributions in small field geometry was included. The plan for each audit step involved a pilot study and a trial audit run with a few local hospitals. The pilot study focused on conducting and evaluation of the audit procedures with all participants. The trial audit run was the running of the audit procedures by the participants to test them with a few local radiotherapy hospitals. This work intends to provide audits which are much nearer clinical practice than previous audits as they involve significant testing of Tps methods, as well as verifications to determinate whether hospitals can correctly calculate dose delivery in radiation treatments. (author)

  4. Development of dose audits for complex treatment techniques in radiotherapy

    International Nuclear Information System (INIS)

    Stefanic, A. M.; Molina, L.; Vallejos, M.; Montano, G.; Zaretzky, A.; Saravi, M.

    2014-08-01

    This work was performed in the frame of a Coordinated Research Project (CRP) with IAEA whose objective was to extend the scope of activities carried out by national TLD-based networks from dosimetry audit for rectangular radiation fields to irregular and small fields relevant to modern radiotherapy. External audit is a crucial element in QA programmes for clinical dosimetry in radiotherapy, therefore a methodology and procedures were developed and were made available for dose measurement of complex radiotherapy parameters used for cancer treatment. There were three audit steps involved in this CRP: TLD based dosimetry for irregular MLC fields for conformal radiotherapy, dosimetry in the presence of heterogeneities and 2D MLC shaped fields relevant to stereotactic radiotherapy and applicable to dosimetry for IMRT. In addition, a new development of film-based 2D dosimetry for testing dose distributions in small field geometry was included. The plan for each audit step involved a pilot study and a trial audit run with a few local hospitals. The pilot study focused on conducting and evaluation of the audit procedures with all participants. The trial audit run was the running of the audit procedures by the participants to test them with a few local radiotherapy hospitals. This work intends to provide audits which are much nearer clinical practice than previous audits as they involve significant testing of Tps methods, as well as verifications to determinate whether hospitals can correctly calculate dose delivery in radiation treatments. (author)

  5. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC. A direct comparison of PET-based treatment planning

    International Nuclear Information System (INIS)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Ruebe, Christian

    2016-01-01

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p < 0.001; IF: 74.3 vs. 70.1 Gy, p < 0.03). With IMRT-IF, a PD of at least 66 Gy was achieved for 95 % of all plans. For IF as compared with ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p < 0.00001; 3D-CRT: 20.2 vs. 9.9 %, p < 0.00001). The esophageal NTCP showed a particularly good sparing with IMRT vs. 3D-CRT (ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels. (orig.) [de

  6. Three-Dimensional Non-Coplanar Conformal Radiotherapy Yields Better Results Than Traditional Beam Arrangements for Adjuvant Treatment of Gastric Cancer

    International Nuclear Information System (INIS)

    Soyfer, Viacheslav; Corn, Benjamin W.; Melamud, Alex B.S.; Alani, Shlomi; Tempelhof, Haim; Agai, Reuben; Shmueli, Anat; Figer, Arie; Kovner, Felix

    2007-01-01

    Purpose: The current standard of adjuvant treatment for gastric cancer after curative resection is concurrent administration of radiotherapy and 5-fluorouracil-based chemotherapy. The radiation fields are often arranged as anterioposterior-posteroanterior opposed parallel fields with general recommendations for sparing at least two-thirds of one kidney. We investigated whether a better radiation distribution would be achievable with three-dimensional conformal approaches compared with the classic anterioposterior-posteroanterior fields. Methods and Materials: A total of 19 patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a non-coplanar four-field arrangement. In each case, parallel planning using an anterioposterior-posteroanterior arrangement and a four-field 'box' was performed, and the generated plans were subsequently compared for coverage of target volumes and doses to irradiated organs next to the tumor bed. A separate analysis was performed for kidneys exposed to greater and lower doses in each patient. The mean radiation dose and percentage of kidney volume receiving a dose >20 Gy were registered. Statistical analysis was performed using the two-tailed t test. Results: The clinical target volume was adequately covered in all three plans. In the greater-dose kidney group, all the differences were statistically significant with a benefit for the three-dimensional plan. In the lower-dose kidney group, the differences in the mean radiation dose did not reach the level of statistical significance, and the differences in the kidney volume receiving a dose >20 Gy showed a statistically significant benefit for the three-dimensional plan. Conclusion: Non-coplanar three-dimensional-based conformal planning for postoperative radiotherapy for gastric cancer provided the best results regarding kidney and spinal cord exposure with adequate clinical target volume coverage. This technique was readily implemented in clinical

  7. Three-dimensional non-coplanar conformal radiotherapy yields better results than traditional beam arrangements for adjuvant treatment of gastric cancer.

    Science.gov (United States)

    Soyfer, Viacheslav; Corn, Benjamin W; Melamud, Alex; Alani, Shlomi; Tempelhof, Haim; Agai, Reuben; Shmueli, Anat; Figer, Arie; Kovner, Felix

    2007-10-01

    The current standard of adjuvant treatment for gastric cancer after curative resection is concurrent administration of radiotherapy and 5-fluorouracil-based chemotherapy. The radiation fields are often arranged as anterioposterior-posteroanterior opposed parallel fields with general recommendations for sparing at least two-thirds of one kidney. We investigated whether a better radiation distribution would be achievable with three-dimensional conformal approaches compared with the classic anterioposterior-posteroanterior fields. A total of 19 patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a non-coplanar four-field arrangement. In each case, parallel planning using an anterioposterior-posteroanterior arrangement and a four-field "box" was performed, and the generated plans were subsequently compared for coverage of target volumes and doses to irradiated organs next to the tumor bed. A separate analysis was performed for kidneys exposed to greater and lower doses in each patient. The mean radiation dose and percentage of kidney volume receiving a dose >20 Gy were registered. Statistical analysis was performed using the two-tailed t test. The clinical target volume was adequately covered in all three plans. In the greater-dose kidney group, all the differences were statistically significant with a benefit for the three-dimensional plan. In the lower-dose kidney group, the differences in the mean radiation dose did not reach the level of statistical significance, and the differences in the kidney volume receiving a dose >20 Gy showed a statistically significant benefit for the three-dimensional plan. Non-coplanar three-dimensional-based conformal planning for postoperative radiotherapy for gastric cancer provided the best results regarding kidney and spinal cord exposure with adequate clinical target volume coverage. This technique was readily implemented in clinical practice.

  8. Application of super-omni wedge concept to conformal radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Dai Jianrong; Fu Weihua; Hu Yimin

    2004-01-01

    Objective: To describe a method which can optimize beam weight, wedge angle, and wedge orientation simultaneously by combining the super-omni wedge (SOW) concept with the function of beam weight optimization provided by a commercial treatment planning system. Methods: A five-step procedure including: Step 1. To set up four 60 degree nominal wedged beams for each beam direction with the wedge orientations of 'LEFT', 'IN', 'RIGHT', 'OUT', respectively; Step 2. To define an optimization request, including an optimization goal and constraints. Authors use CMS Focus treatment planning system which allows us to choose 'maximize target dose' or 'minimize critical structure dose' as the optimization goal, and to set minimum target dose, maximum target dose, and maximum average dose of critical structures as constraints. Then the optimization process was launched as step 3; Step 4. To evaluate the plan using isodose distributions and dose-volume histograms. If acceptable, go to Step 5. Otherwise, go back to Step 2 to modify optimization constraints; and Step 5. Transform the SOW beams into the beams of omni wedge so as to reduce the number of to-be-delivered beams. Results: This procedure was found being able to demonstrate successfully in two clinical cases: an esophageal carcinoma and a brain tumor. Compared with manually designed plan, the optimized plan showed better dose homogeneity in the targets and better sparing of the critical structures. Conclusions: This method described is able to optimize beam weights while working with a treatment planning system. Not only does it improve treatment plans' quality, but also shorten the treatment planning process

  9. Shortening treatment time in robotic radiosurgery using a novel node reduction technique

    Energy Technology Data Exchange (ETDEWEB)

    Water, Steven van de; Hoogeman, Mischa S.; Breedveld, Sebastiaan; Heijmen, Ben J. M. [Department of Radiation Oncology, Erasmus MC-Daniel den Hoed Cancer Center, Groene Hilledijk 301, 3075 EA Rotterdam (Netherlands)

    2011-03-15

    Purpose: The fraction duration of robotic radiosurgery treatments can be reduced by generating more time-efficient treatment plans with a reduced number of node positions, beams, and monitor units (MUs). Node positions are preprogramed locations where the robot can position the focal spot of the x-ray beam. As the time needed for the robot to travel between node positions takes up a large part of the treatment time, the aim of this study was to develop and evaluate a node reduction technique in order to reduce the treatment time per fraction for robotic radiosurgery. Methods: Node reduction was integrated into the inverse planning algorithm, developed in-house for the robotic radiosurgery modality. It involved repeated inverse optimization, each iteration excluding low-contribution node positions from the planning and resampling new candidate beams from the remaining node positions. Node reduction was performed until the exclusion of a single node position caused a constraint violation, after which the shortest treatment plan was selected retrospectively. Treatment plans were generated with and without node reduction for two lung cases of different complexity, one oropharyngeal case and one prostate case. Plan quality was assessed using the number of node positions, beams and MUs, and the estimated treatment time per fraction. All treatment plans had to fulfill all clinical dose constraints. Extra constraints were added to maintain the low-dose conformality and restrict skin doses during node reduction. Results: Node reduction resulted in 12 residual node positions, on average (reduction by 77%), at the cost of an increase in the number of beams and total MUs of 28% and 9%, respectively. Overall fraction durations (excluding patient setup) were shortened by 25% (range of 18%-40%), on average. Dose distributions changed only little and dose in low-dose regions was effectively restricted by the additional constraints. Conclusions: The fraction duration of robotic

  10. Shortening treatment time in robotic radiosurgery using a novel node reduction technique

    International Nuclear Information System (INIS)

    Water, Steven van de; Hoogeman, Mischa S.; Breedveld, Sebastiaan; Heijmen, Ben J. M.

    2011-01-01

    Purpose: The fraction duration of robotic radiosurgery treatments can be reduced by generating more time-efficient treatment plans with a reduced number of node positions, beams, and monitor units (MUs). Node positions are preprogramed locations where the robot can position the focal spot of the x-ray beam. As the time needed for the robot to travel between node positions takes up a large part of the treatment time, the aim of this study was to develop and evaluate a node reduction technique in order to reduce the treatment time per fraction for robotic radiosurgery. Methods: Node reduction was integrated into the inverse planning algorithm, developed in-house for the robotic radiosurgery modality. It involved repeated inverse optimization, each iteration excluding low-contribution node positions from the planning and resampling new candidate beams from the remaining node positions. Node reduction was performed until the exclusion of a single node position caused a constraint violation, after which the shortest treatment plan was selected retrospectively. Treatment plans were generated with and without node reduction for two lung cases of different complexity, one oropharyngeal case and one prostate case. Plan quality was assessed using the number of node positions, beams and MUs, and the estimated treatment time per fraction. All treatment plans had to fulfill all clinical dose constraints. Extra constraints were added to maintain the low-dose conformality and restrict skin doses during node reduction. Results: Node reduction resulted in 12 residual node positions, on average (reduction by 77%), at the cost of an increase in the number of beams and total MUs of 28% and 9%, respectively. Overall fraction durations (excluding patient setup) were shortened by 25% (range of 18%-40%), on average. Dose distributions changed only little and dose in low-dose regions was effectively restricted by the additional constraints. Conclusions: The fraction duration of robotic

  11. Nasopharynx carcinoma treatment: from the conventional radiotherapy to the conformal radiotherapy with intensity modulation; Traitement du carcinome du nasopharynx: de la radiotherapie conventionnelle a la radiotherapie conformationnelle avec modulation d'intensite

    Energy Technology Data Exchange (ETDEWEB)

    Mokaouim, K.; Grehange, G.; Truc, G.; Peingnaux, K.; Martin, E.; Zanetta, S.; Bruchon, Y.; Bonnetain, F.; Maingon, P. [Centre Georges-Francois Leclerc, 21 - Dijon (France)

    2009-10-15

    The objective of this study was to evaluate retrospectively the impact of factors linked to the radiotherapy realisation on the local and locoregional control, the global survival, the survival without disease of patients suffering of naso-pharynx carcinoma. Conclusion: the patients suffering of a nasopharynx carcinoma treated by irradiation associated to chemotherapy have an improved global survival and an improved survival without disease. The conformal radiotherapy with or without modulated intensity reduce the risk of serous otitis, trismus and xerostomia at long term. It seems necessary to realize multi centric studies with a longer period of follow up before asserting the advantages of the I.M.R.T. in comparison to the classical and conformal technique in the treatment of naso-pharynx carcinomas. (N.C.)

  12. Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer

    International Nuclear Information System (INIS)

    Mah, Dennis; Hanley, Joseph; Rosenzweig, Kenneth E.; Yorke, Ellen; Braban, Louise; Ling, C. Clifton; Leibel, Stephen A.; Mageras, Gikas

    2000-01-01

    Purpose: The goal of this paper is to describe our initial experience with the deep inspiration breath-hold (DIBH) technique in conformal treatment of non-small-cell lung cancer with particular emphasis on the technical aspects required for implementation. Methods and Materials: In the DIBH technique, the patient is verbally coached through a modified slow vital capacity maneuver and brought to a reproducible deep inspiration breath-hold level. The goal is to immobilize the tumor and to expand normal lung out of the high-dose region. A physicist or therapist monitors and records patient breathing during simulation, verification, and treatment using a spirometer with a custom computer interface. Examination of internal anatomy during fluoroscopy over multiple breath holds establishes the reproducibility of the DIBH maneuver for each patient. A reference free-breathing CT scan and DIBH planning scan are obtained. To provide an estimate of tumor motion during normal tidal breathing, additional scan sets are obtained at end inspiration and end expiration. These are also used to set the spirometer action levels for treatment. Patient lung inflation is independently verified over the course of treatment by comparing the distance from the isocenter to the diaphragm measured from the DIBH digitally reconstructed radiographs to the distance measured on the portal films. Patient breathing traces obtained during treatment were examined retrospectively to assess the reproducibility of the technique. Results: Data from the first 7 patients, encompassing over 250 treatments, were analyzed. The inferred displacement of the centroid of gross tumor volume from its position in the planning scan, as calculated from the spirometer records in over 350 breath holds was 0.02 ± 0.14 cm (mean and standard deviation). These data are consistent with the displacements of the diaphragm (-0.1 ± 0.4 cm; range, from -1.2 to 1.1 cm) relative to the isocenter, as measured on the (92) portal films

  13. Induction chemotherapy plus three-dimensional conformal radiation therapy in the definitive treatment of locally advanced non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Sim, Sang; Rosenzweig, Kenneth E.; Schindelheim, Rachel; Ng, Kenneth K.; Leibel, Steven A.

    2001-01-01

    Purpose: To evaluate our institution's experience using chemotherapy in conjunction with three-dimensional conformal radiation therapy (3D-CRT). Methods and Materials: From 1991 to 1998, 152 patients with Stage III non-small-cell lung cancer (NSCLC) were treated with 3D-CRT at Memorial Sloan-Kettering Cancer Center. A total of 137 patients (90%) were surgically staged with either thoracotomy or mediastinoscopy. The remainder were staged radiographically. Seventy patients were treated with radiation therapy alone, and 82 patients received induction chemotherapy before radiation. The majority of chemotherapy-treated patients received a platinum-containing regimen. Radiation was delivered with a 3D conformal technique using CT-based treatment planning. The median dose in the radiation alone group was 70.2 Gy, while in the combined modality group, it was 64.8 Gy. Results: The median follow-up time was 30.5 months among survivors. Stage IIIB disease was present in 36 patients (51%) in the radiation-alone group and 57 patients (70%) in the combined-modality group. Thirty-nine patients had poor prognostic factors (KPS 5%), and they were equally distributed between the two groups. The median survival times for the radiation-alone and the combined-modality groups were 11.7 months and 18.1 months, respectively (p=0.001). The 2-year rates of local control in the radiation-alone and combined-modality groups were 35.4% and 43.1%, respectively (p=0.1). Grade 3 or worse nonhematologic toxicity occurred in 20% of the patients receiving radiation alone and in 16% of those receiving chemotherapy and radiation. Overall, there were only 4 cases of Grade 3 or worse esophagitis. Conclusion: Despite more Stage IIIB patients in the combined-modality group, the addition of chemotherapy to 3D-CRT produced a survival advantage over 3D-CRT alone in Stage III NSCLC without a concomitant increase in toxicity. Chemotherapy thus appears to be beneficial, even in patients who are receiving higher

  14. Transportation Conformity

    Science.gov (United States)

    This section provides information on: current laws, regulations and guidance, policy and technical guidance, project-level conformity, general information, contacts and training, adequacy review of SIP submissions

  15. Analysis of a flip-chip bonded tunable high-temperature superconducting coplanar waveguide resonator using the conformal mapping technique

    CERN Document Server

    Misra, M; Murakami, H; Tonouchi, M

    2003-01-01

    We have studied the tuning properties of a high-temperature superconducting (HTS) half-wavelength coplanar waveguide (CPW) resonator operating at 5 GHz. The tuning schemes are based on flip-chip bonding of an electrically tunable ferroelectric (FE) thin film and a mechanically movable low-loss single crystal on top of the resonator. Using the conformal mapping method, closed-form analytical expressions have been derived for a flip-chip bonded conductor-backed and top-shielded CPW transmission line. The obtained expressions are used to analyse the volume effect of the FE thin film and the gap between the flip-chip and the CPW resonator on the tuning properties of the device. It has been found that large frequency modulation of the resonator produces impedance mismatch, which can considerably enhance the insertion loss of high-performance HTS microwave devices. Analysis also suggests that, for electrically tunable devices, flip-chip bonded FE thin films on HTS CPW devices provide a relatively higher performance...

  16. New techniques for the treatment of uranium ores

    International Nuclear Information System (INIS)

    Renaud, J.; Boutonnet, G.

    1977-01-01

    The growth in nuclear power programmes since 1970 has led to an increasing demand for uranium, and tenders have been invited from all parts of the world for the construction of new treatment plants. What types of plant could be suggested. The diversity of ores and sites, even more stringent safety requirements, greater care for the environment and economic facts called for numerous, if not basic, reviews of the conventional techniques. Two examples illustrate this point. In the case of a plant to treat a refractory ore situated in a desert area with limited water resources, Pechiney Ugine Kuhlmann studied and applied a new technique of leaching by sulphuric acid pulping, which gives a considerable saving of sulphuric acid and water in comparison with conventional leaching techniques. In dealing with a problem which arose at a plant situated in a mountainous region of touristic interest, where a tailings settling tank could not be installed, Pechiney Ugine Kuhlmann studied and developed techniques involving the use of band filters for solid-liquid separation and pulp washing. Apart from lowering investment costs by about 15% in comparison with the techniques used so far, this technique produces the tailings in solid form so that they do not require a settling tank for storage. (author)

  17. Treatment and disposal techniques of dangerous municipal solid wastes

    International Nuclear Information System (INIS)

    Beone, G.; Carbone, A.I.; Zagaroli, M.

    1989-01-01

    This paper describes the qualitative and quantitative features of the different types of dangerous municipal solid wastes, according to Italian law. In the second part the impact on environment and man health is presented. This impact should be minimized by suitable controlled disposal techniques, which differ from other municipal waste treatments. Finally, the paper deals with the most appropriate systems for treatment and disposal of such kind of waste. Particularly, some research activities in the field of metal recovery from used batteries, sponsored by ENEA, and carrying out by private companies, are described. (author)

  18. An accurate calibration method of the multileaf collimator valid for conformal and intensity modulated radiation treatments

    Energy Technology Data Exchange (ETDEWEB)

    Sastre-Padro, Maria; Heide, Uulke A van der; Welleweerd, Hans [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2004-06-21

    Because for IMRT treatments the required accuracy on leaf positioning is high, conventional calibration methods may not be appropriate. The aim of this study was to develop the tools for an accurate MLC calibration valid for conventional and IMRT treatments and to investigate the stability of the MLC. A strip test consisting of nine adjacent segments 2 cm wide, separated by 1 mm and exposed on Kodak X-Omat V films at D{sub max} depth, was used for detecting leaf-positioning errors. Dose profiles along the leaf-axis were taken for each leaf-pair. We measured the dose variation on each abutment to quantify the relative positioning error (RPE) and the absolute position of the abutment to quantify the absolute positioning error (APE). The accuracy of determining the APE and RPE was 0.15 and 0.04 mm, respectively. Using the RPE and the APE the MLC calibration parameters were calculated in order to obtain a flat profile on the abutment at the correct position. A conventionally calibrated Elekta MLC was re-calibrated using the strip test. The stability of the MLC and leaf-positioning reproducibility was investigated exposing films with 25 adjacent segments 1 cm wide during three months and measuring the standard deviation of the RPE values. A maximum shift over the three months of 0.27 mm was observed and the standard deviation of the RPE values was 0.11 mm.

  19. An accurate calibration method of the multileaf collimator valid for conformal and intensity modulated radiation treatments

    International Nuclear Information System (INIS)

    Sastre-Padro, Maria; Heide, Uulke A van der; Welleweerd, Hans

    2004-01-01

    Because for IMRT treatments the required accuracy on leaf positioning is high, conventional calibration methods may not be appropriate. The aim of this study was to develop the tools for an accurate MLC calibration valid for conventional and IMRT treatments and to investigate the stability of the MLC. A strip test consisting of nine adjacent segments 2 cm wide, separated by 1 mm and exposed on Kodak X-Omat V films at D max depth, was used for detecting leaf-positioning errors. Dose profiles along the leaf-axis were taken for each leaf-pair. We measured the dose variation on each abutment to quantify the relative positioning error (RPE) and the absolute position of the abutment to quantify the absolute positioning error (APE). The accuracy of determining the APE and RPE was 0.15 and 0.04 mm, respectively. Using the RPE and the APE the MLC calibration parameters were calculated in order to obtain a flat profile on the abutment at the correct position. A conventionally calibrated Elekta MLC was re-calibrated using the strip test. The stability of the MLC and leaf-positioning reproducibility was investigated exposing films with 25 adjacent segments 1 cm wide during three months and measuring the standard deviation of the RPE values. A maximum shift over the three months of 0.27 mm was observed and the standard deviation of the RPE values was 0.11 mm

  20. Conservation treatment of the eye: Conformal proton reirradiation for recurrent uveal melanoma

    International Nuclear Information System (INIS)

    Marucci, Laura; Lane, Anne M.; Li Wenjun; Egan, Kathleen M.; Gragoudas, Evangelos S.; Adams, Judy; Collier, John M.; Munzenrider, John E.

    2006-01-01

    Purpose: To evaluate the outcomes of a second course of proton beam radiation therapy (PBRT) in patients with recurrent uveal melanoma. Methods and Materials: Thirty-one patients received a second course of PBRT. The mean interval between the first and the second PBRT course was 50.2 months (range, 8-165 months). Most patients (87%) received 70 cobalt Gray equivalent (CGE) for both courses. Visual acuity was 20/200 or better in 30 patients initially and in 22 patients at the second treatment. The mean follow-up time after the second treatment was 50 months (range, 6-164 months). Results: At the time of the last follow-up, 20 patients were classified as having no evidence of disease, defined as tumor regression or an absence of tumor progression. Nine eyes (29%) were enucleated because of local recurrence (n = 5) or intractable pain (n = 4). The 5-year eye retention rate was 55% (95% confidence interval: 25.2-77.4). Six of the 22 patients who retained the eye (27%) had useful vision (20/200 or better). Conclusions A second course of PBRT for recurrent uveal melanoma to total doses between 118 and 140 CGE was associated with a relatively good probability of local control and a low enucleation rate. Although most patients lost vision, the majority were able to retain the reirradiated eye. Further evaluation is needed to assess metastasis-free survival of additional proton irradiation vs. enucleation after local recurrence

  1. Effects of heat treatment on conformation and cell growth activity of alpha- lactalbumin and beta-lactoglobulin from market milk.

    Science.gov (United States)

    Inagaki, Mizuho; Kawai, Shuji; Ijier, X; Fukuoka, Mayuko; Yabe, Tomio; Iwamoto, Satoshi; Kanamaru, Yoshihiro

    2017-01-01

    Heat processes, low temperature for long time (LTLT) pasteurization and ultra-heat treatment (UHT) sterilization, are essential for commercial market milk to improve the shelf life of raw milk and ensure microbial safety. We evaluated the effects of heat experience on the molecular properties of α-lactalbumin (α-LA) and β-lactoglobulin (β-LG) isolated from four types of market milk such as LTLT-A (66°C for 30 min), LTLT-B (65°C for 30 min), UHT-I (130°C for 2 s, indirect heating) and UHT-D (135°C for 2 s, direct heating) samples. We examined molecular conformations using circular dichroism spectrum measurement and cell growth activity using the WST-1 method for the proteins. α-LA isolated from each of these four types of market milk displayed no significant structural difference as compared to raw milk α-LA, while α-LA of UHT-I only inhibited cell growth of an intestinal epithelial cell line more potently than raw milk α-LA. In the case of β-LG, only the UHT-I sample demonstrated a drastic change in structure, while it did not exhibit any cytotoxicity. We found that cell viability effects of α-LA and β-LG are attributable to the type of UHT; indirect and direct. These findings indicate that the effect of heat treatment on whey proteins should carefully be investigated further.

  2. Dosimetric comparison of metastatic spinal photon treatment techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ewing, Marvene M., E-mail: mewing@iuhealth.org [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States); Carnes, Samuel M.; Henderson, Mark A.; Das, Indra J. [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States)

    2012-01-01

    Traditional palliative treatment of metastatic cancer to the vertebral bodies often results in doses to the spinal cord that are higher than the dose prescribed to the target, or gross tumor volume (GTV). This study compares traditional techniques of spine palliation with intensity-modulated radiation therapy (IMRT). The purpose of the study is 2-fold: first, the study demonstrates the benefits of using IMRT to lower the dose to the organs at risk (OAR), particularly for the spinal cord and other nonspecified normal tissues; second, the article provides information regarding the advantages and disadvantages of commonly used conventional techniques for treating the vertebral bodies based on patient anatomy. Because the use of IMRT or other advanced techniques may be prohibitive because of insurance issues, treatment plans were created that compared optimal coverage vs. optimal sparing for single-field, wedged-pair, and opposed-beam arrangements. Fifty-five patients were selected and divided by location of target (cervical, thoracic, and lumbar spine) and also by the measured separation between the anterior and posterior surface of the patient at the level of mid-GTV. Within each anatomic category the patients again were divided into the categories of small, medium, and large based on separation. The patient dataset that most closely represented the average separation within each category was selected, resulting in a total of 9 patients, and the appropriate treatment plan techniques were calculated for each of the 9 patients. The results of the study do show that the use of IMRT is far superior when compared with other techniques, both for coverage and for sparing of the surrounding tissue, regardless of patient size and the section of spine being treated. Based on a combination of both target coverage and sparing of normal tissues, the conventional plan of choice may vary by both the section of spine to be treated and by the size of the patient.

  3. Potential applications of plasma science techniques for water treatment systems

    International Nuclear Information System (INIS)

    Pavlik, D.

    1994-01-01

    The historical evolution of water treatment techniques and their impact on man and his environment are presented. Ancient man recognized the relationship between good water and good health. However, it was not until the late 1800's that man's own contribution to the pollution of water via biological and chemical contamination of the water stream was recognized as having adverse affects on water quality. Since that time virtually every nation has adopted laws and regulations to ensure that safe sources of unpolluted water are available to its citizens. In the United States, water quality is governed by the Clean Water Act of 1972 administered at the federal level by the Environmental Protection Agency (EPA). Further, each state has established its equivalent agency which administers its own laws and regulations. Different biological and chemical biohazards present in the water system are discussed. Biological contaminants include various types of viruses, bacteria, fungii, molds, yeasts, algae, amoebas, and parasites. Chemical contaminates include elemental heavy metals and other organic and inorganic compounds which interfere with normal biological functions. Conventional water treatments for both consumption and sewage effluent commonly employ four different principals: mechanical filtration, quiescent gravity settling, biological oxidation, and chemical treatment. Although these techniques have greatly reduced the incidence of water-borne disease recent studies suggest that more effective means of eliminating biohazards are needed. Regulatory requirements for more aggressive treatment and elimination of residual contaminants present a significant opportunity for the application of various forms of electromagnetic radiation techniques. A comparison between conventional techniques and more advanced methods using various forms of electromagnetic radiation is discussed

  4. Clinical variability of target volume description and treatment plans in conformal radiotherapy in muscle invasive bladder cancer

    International Nuclear Information System (INIS)

    Logue, John P; Sharrock, Carole L; Cowan, Richard A.; Read, Graham; Marrs, Julie; Mott, David

    1996-01-01

    Purpose/Objective: The delineation of tumor and the production of a treatment plan to encompass this is the prime step in radiotherapy planning. Conformal radiotherapy is developing rapidly and although plentiful research has addressed the implementation of the radiotherapy prescription, scant attention has been made to the fundamental step of production, by the clinician, of an appropriate target volume. As part of an ongoing randomized trial of conformal radiotherapy, in bladder cancer, we have therefore assessed the interphysician variability of radiologists and radiation oncologists (RO) in assessing Gross Tumor Volume(GTV) (ICRU 50) and the adherence of the radiation oncologists to the study protocol of producing a Planning Target Volume (PTV). Materials and Methods: Four patients with T3 carcinoma of bladder who had been entered into the trial were identified. The clinical details, MR scans and CT scans were made available. Eight RO and 3 dedicated diagnostic oncology radiologists were invited to directly outline the GTV onto CT images on a planning computer consul. The RO in addition created a PTV following the trial protocol of 15mm margin around the GTV. Three RO sub-specialized in Urological radiotherapy; all RO had completed training. Volumes were produced, for each clinician, and comparison of these volumes and their isocenters were analyzed. In addition the margins allowed were measured and compared. Results: There was a maximum variation ratio (largest to smallest volume outlined) of the GTV in the four cases of 1.74 among radiologists and 3.74 among oncologists. There was a significant difference (p=0.01) in mean GTV between RO and the radiologists. The mean GTV of the RO exceeded the radiologists by a factor of 1.29 with a mean difference of 13.4 cm 3 The between observer variance within speciality comprised only 9.9% of the total variance in the data having accounted for case and observers speciality. The variation ratio in PTV among oncologists

  5. An IHE-conform telecooperation platform supporting the treatment of dementia patients

    Directory of Open Access Journals (Sweden)

    Saleh K.

    2015-09-01

    Full Text Available Ensuring medical support of patients of advanced age in rural areas is a major challenge. Moreover, the number of registered doctors—medical specialists in particular—will decrease in such areas over the next years. These unmet medical needs in combination with communication deficiencies among different types of health-care professionals pose threats to the quality of patient treatment. This work presents a novel solution combining telemedicine, telecooperation, and IHE profiles to tackle these challenges. We present a telecooperation platform that supports longitudinal electronic patient records and allows for intersectoral cooperation based on shared electronic medication charts and other documents. Furthermore, the conceived platform allows for an integration into the planned German telematics infrastructure.

  6. Workers’ Conformism

    Directory of Open Access Journals (Sweden)

    Nikolay Ivantchev

    2013-10-01

    Full Text Available Conformism was studied among 46 workers with different kinds of occupations by means of two modified scales measuring conformity by Santor, Messervey, and Kusumakar (2000 – scale for perceived peer pressure and scale for conformism in antisocial situations. The hypothesis of the study that workers’ conformism is expressed in a medium degree was confirmed partly. More than a half of the workers conform in a medium degree for taking risk, and for the use of alcohol and drugs, and for sexual relationships. More than a half of the respondents conform in a small degree for anti-social activities (like a theft. The workers were more inclined to conform for risk taking (10.9%, then – for the use of alcohol, drugs and for sexual relationships (8.7%, and in the lowest degree – for anti-social activities (6.5%. The workers who were inclined for the use of alcohol and drugs tended also to conform for anti-social activities.

  7. Treatment of complex electroplating waste by 'zero discharge' technique

    International Nuclear Information System (INIS)

    Khattak, B.Q.; Ram Sankar, P.; Jain, A.K.

    2009-01-01

    Surface treatment processes generate lot of liquid waste, which contains toxic substances and are potentially harmful to the living beings. It is extremely difficult to treat the pollutants where processes and frequencies are not fixed. In Chemical Treatment Facility of RRCAT, surface treatment processes are user dependent and makes the electroplating waste very complicated. Initially the waste was treated by simple chemical transformation technique in which heavy metal ions are converted to hydroxide precipitates. Non metallic ions that contribute much to the plating waste could not be treated by this process. To remove maximum possible pollutants, many experiments were conducted on the laboratory scale. Based on those results, a pilot ion exchange plant of various resins was introduced in the process to achieve disposal quality effluent. Anionic load of Phosphate, Nitrate and fluoride caused frequent anionic bed exhaustions and polymeric network damaging. To avoid this phenomenon a new setup was designed. This pre treatment has the capacity to treat 500 litres per hour connected to a platter with clarifier followed by high pressure carbon and pebbles filters. Analysis of these ions was carried out on the advanced ion chromatography system and is found free of toxic metals, phosphate and fluoride. This effluent can be reused by adding a reverse osmosis system followed by ion exchange system to produce good quality de mineralized water needed for surface treatment activities. In this paper we describe the existing status of effluent treatment facility and future plans for achieving 'zero discharge'. (author)

  8. Electron/photon matched field technique for treatment of orbital disease

    International Nuclear Information System (INIS)

    Arthur, Douglas W.; Zwicker, Robert D.; Garmon, Pamela W.; Huang, David T.; Schmidt-Ullrich, Rupert K.

    1997-01-01

    Purpose: A number of approaches have been described in the literature for irradiation of malignant and benign diseases of the orbit. Techniques described to date do not deliver a homogeneous dose to the orbital contents while sparing the cornea and lens of excessive dose. This is a result of the geometry encountered in this region and the fact that the target volume, which includes the periorbital and retroorbital tissues but excludes the cornea, anterior chamber, and lens, cannot be readily accommodated by photon beams alone. To improve the dose distribution for these treatments, we have developed a technique that combines a low-energy electron field carefully matched with modified photon fields to achieve acceptable dose coverage and uniformity. Methods and Materials: An anterior electron field and a lateral photon field setup is used to encompass the target volume. Modification of these fields permits accurate matching as well as conformation of the dose distribution to the orbit. A flat-surfaced wax compensator assures uniform electron penetration across the field, and a sunken lead alloy eye block prevents excessive dose to the central structures of the anterior segment. The anterior edge of the photon field is modified by broadening the penumbra using a form of pseudodynamic collimation. Direct measurements using film and ion chamber dosimetry were used to study the characteristics of the fall-off region of the electron field and the penumbra of the photon fields. >From the data collected, the technique for accurate field matching and dose uniformity was generated. Results: The isodose curves produced with this treatment technique demonstrate homogeneous dose coverage of the orbit, including the paralenticular region, and sufficient dose sparing of the anterior segment. The posterior lens accumulates less than 40% of the prescribed dose, and the lateral aspect of the lens receives less than 30%. A dose variation in the match region of ±12% is confronted when

  9. A new technique in the surgical treatment of Hangman's fractures: Neurospinal Academy (NSA) technique.

    Science.gov (United States)

    Dalbayrak, Sedat; Yaman, Onur; Yılmaz, Mesut

    2013-07-01

    Treatment of Hangman's fractures is still controversial. Hangman's fractures Type II and IIA are usually treated with surgical procedures. This study aims at describing the Neurospinal Academy (NSA) technique as an attempt to achieve an approximation of the fracture line to the axis body, which may be used for Type II and IIA patients with severe displacement and angulation. NSA technique both pars or pedicle screws are placed bicortically to ensure that anterior surface of C2 vertebral body will be crossed 1-2 mm. A rod is prepared in suitable length and curve to connect the two screws. For placing the rod, sufficient amount of bone is resected from the C2 spinous process. C2 vertebral body is pulled back by means of the screws that crossed the anterior surface of C2 vertebral body. Hangman II and IIA patient are treated with NSA technique. Angulated and tilted C2 vertebral body was pulled back and approximated to posterior elements. In Hangman's fractures Type II and IIA with severe vertebral body and pedicle displacement, NSA technique is an effective and reliable treatment alternative for the approximation of posterior elements to the C2 vertebral body, which is tilted, angulated, and dislocated.

  10. A new technique in the surgical treatment of Hangman′s fractures: Neurospinal Academy (NSA technique

    Directory of Open Access Journals (Sweden)

    Sedat Dalbayrak

    2013-01-01

    Full Text Available Context: Treatment of Hangman′s fractures is still controversial. Hangman′s fractures Type II and IIA are usually treated with surgical procedures. Aim: This study aims at describing the Neurospinal Academy (NSA technique as an attempt to achieve an approximation of the fracture line to the axis body, which may be used for Type II and IIA patients with severe displacement and angulation. Settings and Design: NSA technique both pars or pedicle screws are placed bicortically to ensure that anterior surface of C2 vertebral body will be crossed 1-2 mm. A rod is prepared in suitable length and curve to connect the two screws. For placing the rod, sufficient amount of bone is resected from the C2 spinous process. C2 vertebral body is pulled back by means of the screws that crossed the anterior surface of C2 vertebral body. Materials and Methods: Hangman II and IIA patient are treated with NSA technique. Result: Angulated and tilted C2 vertebral body was pulled back and approximated to posterior elements. Conclusions: In Hangman′s fractures Type II and IIA with severe vertebral body and pedicle displacement, NSA technique is an effective and reliable treatment alternative for the approximation of posterior elements to the C2 vertebral body, which is tilted, angulated, and dislocated.

  11. Results of Three-Dimensional Conformal Radiation Therapy for the Treatment of a Solitary Sternal Relapse of Breast Cancer

    International Nuclear Information System (INIS)

    Kim, Hae Young; Huh, Seung Jae; Park, Won; Choi, Do Ho; Kang, Min Kyu; Yang, Jung Hyun; Nam, Seok Jin; Im, Young Hyuck

    2008-01-01

    To evaluate the response and survival rate after three-dimensional conformal radiation therapy (3D-CRT) of patients with a solitary sternal relapse of breast cancer. Seventeen patients between May 1996 and June 2005 were evaluated with the salvage 3D-CRT treatment of a solitary sternal relapse of breast cancer. The treatment fields included the gross tumor volume with 2 cm margins. The total radiation dose was 35.0 ∼61.5 Gy (biologic effective dose of 43.7 ∼76.9 Gy10 using an α/β ratio of 10 Gy), with a daily dose of 1.8∼3.0 Gy. The tumor response was evaluated by the change in maximum tumor size via follow up CT scans 1∼3 months after the completion of treatment. An objective tumor response was achieved in all patients, with a complete response in 5 patients and a partial response in 12 patients. The 5-year overall survival rate was 51.9% (median survival time: 27 months), and the most important factor affecting overall survival was the disease-free interval (interval from primary surgery of breast cancer to the development of sternal metastasis): The 5-year overall survival rate was 61.8% for patients with a disease-free interval ≥12 months and 0.0% for patients < with disease-free interval <12 months (p=0.03). The response to 3D-CRT was good in patients with solitary sternal relapse of breast cancer. Particularly, patients with long disease-free interval from primary surgery survived significantly longer than patients with short disease-free interval from primary surgery

  12. Conformal sequestering simplified

    International Nuclear Information System (INIS)

    Schmaltz, Martin; Sundrum, Raman

    2006-01-01

    Sequestering is important for obtaining flavor-universal soft masses in models where supersymmetry breaking is mediated at high scales. We construct a simple and robust class of hidden sector models which sequester themselves from the visible sector due to strong and conformally invariant hidden dynamics. Masses for hidden matter eventually break the conformal symmetry and lead to supersymmetry breaking by the mechanism recently discovered by Intriligator, Seiberg and Shih. We give a unified treatment of subtleties due to global symmetries of the CFT. There is enough review for the paper to constitute a self-contained account of conformal sequestering

  13. The New Nitinol Conformable Self-Expandable Metal Stents for Malignant Colonic Obstruction: A Pilot Experience as Bridge to Surgery Treatment

    Directory of Open Access Journals (Sweden)

    Roberto Di Mitri

    2014-01-01

    Full Text Available Introduction. Self-expandable metal stents (SEMS are a nonsurgical option for treatment of malignant colorectal obstruction also as a bridge to surgery approach. The new nitinol conformable stent has improved clinical outcomes in these kinds of patients. We report a pilot experience with nitinol conformable SEMS placement as bridge to surgery treatment in patients with colorectal obstruction. Materials and Methods. Between April and August 2012, we collected data on colonic nitinol conformable SEMS placement in a cohort of consecutive symptomatic patients, with malignant colorectal obstruction, who were treated as a bridge to surgery. Technical success, clinical success, and adverse events were recorded. Results. Ten patients (7 male (70%, with a mean age of 69.2 ± 10.1, were evaluated. The mean length of the stenosis was 3.6 ± 0.6 cm. Five patients (50% were treated on an emergency basis. The median time from stent placement to surgery was 16 days (interquartile range 7–21. Technical and clinical success was achieved in all patients with a significant early improvement of symptoms. No adverse events due to the SEMS placement were observed. Conclusion. This pilot study confirmed the important role of nitinol conformable SEMS as a bridge to surgery option in the treatment of symptomatic malignant colorectal obstruction.

  14. Domestic comparison of radiation treatment techniques for breast cancer: 3D-CRT, IMRT and VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bo Ram; Yoon, Myong Geun [Dept. of Bio-convergence Engineering, College of Health Science, Korea University, Seoul (Korea, Republic of); Lee, Sun Young [Dept. of Radiation Oncology, Yusung Sun Medical Center, Daejeon (Korea, Republic of)

    2013-09-15

    The purpose of this study is to compare method in the treatment of breast cancer using dose index. And, it is to find the optimized treatment technique to the patient. The phantom filled with tissue-equivalent material were used simulation and treatment as techniques of 3D-CRT, IMRT, VMAT was planned using Eclipse v10. By using HI(homogeneity index), CI(Conformity index), OE (Organ equivalent dose), EAR(Excess Absolute Risk), were assessed for each treatment plans. HI and CI of 3D-CRT, IMRT, VMAT were calculated 16.89, 11.21, 9.55 and 0.59, 0.61, 0.83. The organ average doses of Lt lung, Rt lung, liver, heart, esophagus, cord, Lt breast, trachea and stomach were 0.01 ∼ 2.02 Gy, 0.36 ∼ 5.01 Gy, 0.25 ∼ 2.49 Gy, 0.14 ∼ 6.92 Gy, 0.03 ∼ 2.02 Gy, 0.01 ∼ 1.06 Gy, 0.25 ∼ 6.08 Gy, 0.08 ∼ 0.59 Gy, 0.01 ∼ 1.34 Gy, respectively. The OED, EAR of the IMRT and VMAT show higher than 3D-CRT. As the result of this study, we could confirm being higher dose index(HI, CI) in IMRT and VMAT than 3D-CRT, but doses of around normal organs was higher IMRT, VMAT than 3D-CRT.

  15. Technique of radiotherapeutic treatment of breast cancer with scarcity means

    International Nuclear Information System (INIS)

    Velazquez M, S.; Carrera M, F.; Bayo L, E.; Gutierrez B, L.; Gomez-Millan B, J.

    1998-01-01

    The objective of this work is to show the particularities in the treatment simulation localization, in the volume selection and in the main planning strategies motive by our scarcity means during the first year of performance. It was utilized a computerized tomograph, an X-ray equipment with tele commanded table. Also it was utilized a radio opaque lattice of marked center and knowing space and also a magnetic pointer for indicating 80 cm length between focus-skin. Putting the patient on an inclined plane of self design and manufacture, it was realized three cuts at different levels over what are limited the clinical target volume (CTV) and it is optimized the isocenter through its determined localization by equations. It was employed equations for the radiobiological prediction about fibrosis and dermatitis. It was utilized another techniques or procedures for planning such as personnel wedges or the dose equilibrium in three points of the breast. It was evaluated toxicities (EORTC-RTOG). The results were as follow: Acute dermatitis (grade 1: 23 %; grade 2: 59 %; grade 3: 18 %). Acute pneumonitis (grade 1: 4.3 %); acute pharyngitis (grade 1: 11 %; grade 2: 3.7 %. In conservator treatment of breast it was obtained excellent aesthetic results in 15 %; good 72 %; moderate 11 %; and bad 3 %. The good aesthetic results by the combined use of the optimization techniques in clinical dosimetry, personnel wedges, isocenter therapy and computerized planning in the radiotherapeutic treatment of the breast cancer. (Author)

  16. Modification of a three-dimensional treatment planning system for the use of multi-leaf collimators in conformation radiotherapy

    International Nuclear Information System (INIS)

    Boesecke, R.; Becker, G.; Alandt, K.; Pastyr, O.; Doll, J.; Schlegel, W.; Lorenz, W.J.

    1991-01-01

    The multi-leaf collimator of the DKFZ is designed as a low cost add-on device for conventional linear accelerators for radiotherapy. The technical specification of the computer controlled collimator is briefly described . A major limitation in the use of the wide capabilities of multi-leaf collimators in the clinic is still an appropriate treatment planning system. This paper describes treatment planning and dose calculation techniques for multi-leaf collimators and shows examples where the capabilities of the collimators are used extensively. (author). 18 refs.; 8 figs.; 2 tabs

  17. Single-arc volumetric-modulated arc therapy (sVMAT) as adjuvant treatment for gastric cancer: Dosimetric comparisons with three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT)

    International Nuclear Information System (INIS)

    Wang, Xin; Li, Guangjun; Zhang, Yingjie; Bai, Sen; Xu, Feng; Wei, Yuquan; Gong, Youling

    2013-01-01

    To compare the dosimetric differences between the single-arc volumetric-modulated arc therapy (sVMAT), 3-dimensional conformal radiotherapy (3D-CRT), and intensity-modulated radiotherapy (IMRT) techniques in treatment planning for gastric cancer as adjuvant radiotherapy. Twelve patients were retrospectively analyzed. In each patient's case, the parameters were compared based on the dose-volume histogram (DVH) of the sVMAT, 3D-CRT, and IMRT plans, respectively. Three techniques showed similar target dose coverage. The maximum and mean doses of the target were significantly higher in the sVMAT plans than that in 3D-CRT plans and in the 3D-CRT/IMRT plans, respectively, but these differences were clinically acceptable. The IMRT and sVMAT plans successfully achieved better target dose conformity, reduced the V 20/30 , and mean dose of the left kidney, as well as the V 20/30 of the liver, compared with the 3D-CRT plans. And the sVMAT technique reduced the V 20 of the liver much significantly. Although the maximum dose of the spinal cord were much higher in the IMRT and sVMAT plans, respectively (mean 36.4 vs 39.5 and 40.6 Gy), these data were still under the constraints. Not much difference was found in the analysis of the parameters of the right kidney, intestine, and heart. The IMRT and sVMAT plans achieved similar dose distribution to the target, but superior to the 3D-CRT plans, in adjuvant radiotherapy for gastric cancer. The sVMAT technique improved the dose sparings of the left kidney and liver, compared with the 3D-CRT technique, but showed few dosimetric advantages over the IMRT technique. Studies are warranted to evaluate the clinical benefits of the VMAT treatment for patients with gastric cancer after surgery in the future

  18. Comparison of rectal volume definition techniques and their influence on rectal toxicity in patients with prostate cancer treated with 3D conformal radiotherapy: a dose-volume analysis

    International Nuclear Information System (INIS)

    Onal, Cem; Topkan, Erkan; Efe, Esma; Yavuz, Melek; Sonmez, Serhat; Yavuz, Aydin

    2009-01-01

    To evaluate the impact of four different rectum contouring techniques and rectal toxicities in patients with treated with 3D conformal radiotherapy (3DCRT). Clinical and dosimetric data were evaluated for 94 patients who received a total dose 3DCRT of 70 Gy, and rectal doses were compared in four different rectal contouring techniques: the prostate-containing CT sections (method 1); 1 cm above and below the planning target volume (PTV) (method 2); 110 mm starting from the anal verge (method 3); and from the anal verge to the sigmoid flexure (method 4). The percentage of rectal volume receiving RT doses (30–70 Gy) and minimum, mean rectal doses were assessed. Median age was 69 years. Percentage of rectal volume receiving high doses (≥ 70 Gy) were higher with the techniques that contoured smaller rectal volumes. In methods 2 and 3, the percentage of rectal volume receiving ≥ 70 Gy was significantly higher in patients with than without rectal bleeding (method 2: 30.8% vs. 22.5%, respectively (p = 0.03); method 3: 26.9% vs. 18.1%, respectively (p = 0.006)). Mean rectal dose was significant predictor of rectal bleeding only in method 3 (48.8 Gy in patients with bleeding vs. 44.4 Gy in patients without bleeding; p = 0.02). Different techniques of rectal contouring significantly influence the calculation of radiation doses to the rectum and the prediction of rectal toxicity. Rectal volume receiving higher doses (≥ 70 Gy) and mean rectal doses may significantly predict rectal bleeding for techniques contouring larger rectal volumes, as was in method 3

  19. Techniques and principles of endoscopic treatment of benign gastrointestinal strictures.

    Science.gov (United States)

    Irani, Shayan; Kozarek, Richard A

    2015-09-01

    The fundamental goal of treating any stenosis is luminal enlargement to ameliorate the underlying obstructive symptoms. Symptoms depend on the etiology and the site of the stricture and may include dysphagia, nausea and vomiting, abdominal pain, obstipation, or frank bowel obstruction. This article compares the various current technologies available for the treatment of gastrointestinal stenoses with regard to ease and site of application, patient tolerance, safety and efficacy data, and cost-benefit ratio. Recent studies indicate that gastrointestinal dilation and stenting have evolved to a point at which in many if not most situations they can be the first line therapy and potentially the final therapy needed to treat the underlying condition. Following techniques and principles in the management of gastrointestinal strictures would allow for the well tolerated and effective treatment of most patients with the tools currently available today.

  20. Conformal Infinity

    Directory of Open Access Journals (Sweden)

    Frauendiener Jörg

    2000-08-01

    Full Text Available The notion of conformal infinity has a long history within the research in Einstein's theory of gravity. Today, ``conformal infinity'' is related with almost all other branches of research in general relativity, from quantisation procedures to abstract mathematical issues to numerical applications. This review article attempts to show how this concept gradually and inevitably evolved out of physical issues, namely the need to understand gravitational radiation and isolated systems within the theory of gravitation and how it lends itself very naturally to solve radiation problems in numerical relativity. The fundamental concept of null-infinity is introduced. Friedrich's regular conformal field equations are presented and various initial value problems for them are discussed. Finally, it is shown that the conformal field equations provide a very powerful method within numerical relativity to study global problems such as gravitational wave propagation and detection.

  1. Conformal Infinity.

    Science.gov (United States)

    Frauendiener, Jörg

    2004-01-01

    The notion of conformal infinity has a long history within the research in Einstein's theory of gravity. Today, "conformal infinity" is related to almost all other branches of research in general relativity, from quantisation procedures to abstract mathematical issues to numerical applications. This review article attempts to show how this concept gradually and inevitably evolved from physical issues, namely the need to understand gravitational radiation and isolated systems within the theory of gravitation, and how it lends itself very naturally to the solution of radiation problems in numerical relativity. The fundamental concept of null-infinity is introduced. Friedrich's regular conformal field equations are presented and various initial value problems for them are discussed. Finally, it is shown that the conformal field equations provide a very powerful method within numerical relativity to study global problems such as gravitational wave propagation and detection.

  2. Conformal Infinity

    Directory of Open Access Journals (Sweden)

    Frauendiener Jörg

    2004-01-01

    Full Text Available The notion of conformal infinity has a long history within the research in Einstein's theory of gravity. Today, 'conformal infinity' is related to almost all other branches of research in general relativity, from quantisation procedures to abstract mathematical issues to numerical applications. This review article attempts to show how this concept gradually and inevitably evolved from physical issues, namely the need to understand gravitational radiation and isolated systems within the theory of gravitation, and how it lends itself very naturally to the solution of radiation problems in numerical relativity. The fundamental concept of null-infinity is introduced. Friedrich's regular conformal field equations are presented and various initial value problems for them are discussed. Finally, it is shown that the conformal field equations provide a very powerful method within numerical relativity to study global problems such as gravitational wave propagation and detection.

  3. General Conformity

    Science.gov (United States)

    The General Conformity requirements ensure that the actions taken by federal agencies in nonattainment and maintenance areas do not interfere with a state’s plans to meet national standards for air quality.

  4. Conformal Infinity

    OpenAIRE

    Frauendiener, J?rg

    2000-01-01

    The notion of conformal infinity has a long history within the research in Einstein's theory of gravity. Today, 'conformal infinity' is related to almost all other branches of research in general relativity, from quantisation procedures to abstract mathematical issues to numerical applications. This review article attempts to show how this concept gradually and inevitably evolved from physical issues, namely the need to understand gravitational radiation and isolated systems within the theory...

  5. Prone Hypofractionated Whole-Breast Radiotherapy Without a Boost to the Tumor Bed: Comparable Toxicity of IMRT Versus a 3D Conformal Technique

    Energy Technology Data Exchange (ETDEWEB)

    Hardee, Matthew E.; Raza, Shahzad; Becker, Stewart J.; Jozsef, Gabor; Lymberis, Stella C. [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States); Hochman, Tsivia; Goldberg, Judith D. [Division of Biostatistics, New York University School of Medicine, New York, NY (United States); DeWyngaert, Keith J. [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States); Formenti, Silvia C., E-mail: silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States)

    2012-03-01

    Purpose: We report a comparison of the dosimetry and toxicity of three-dimensional conformal radiotherapy (3D-CRT) vs. intensity-modulated radiotherapy (IMRT) among patients treated in the prone position with the same fractionation and target of the hypofractionation arm of the Canadian/Whelan trial. Methods and Materials: An institutional review board-approved protocol identified a consecutive series of early-stage breast cancer patients treated according to the Canadian hypofractionation regimen but in the prone position. Patients underwent IMRT treatment planning and treatment if the insurance carrier approved reimbursement for IMRT; in case of refusal, a 3D-CRT plan was used. A comparison of the dosimetric and toxicity outcomes during the acute, subacute, and long-term follow-up of the two treatment groups is reported. Results: We included 97 consecutive patients with 100 treatment plans in this study (3 patients with bilateral breast cancer); 40 patients were treated with 3D-CRT and 57 with IMRT. IMRT significantly reduced the maximum dose (Dmax median, 109.96% for 3D-CRT vs. 107.28% for IMRT; p < 0.0001, Wilcoxon test) and improved median dose homogeneity (median, 1.15 for 3D-CRT vs. 1.05 for IMRT; p < 0.0001, Wilcoxon test) when compared with 3D-CRT. Acute toxicity consisted primarily of Grade 1 to 2 dermatitis and occurred in 92% of patients. Grade 2 dermatitis occurred in 13% of patients in the 3D-CRT group and 2% in the IMRT group. IMRT moderately decreased rates of acute pruritus (p = 0.03, chi-square test) and Grade 2 to 3 subacute hyperpigmentation (p = 0.01, Fisher exact test). With a minimum of 6 months' follow-up, the treatment was similarly well tolerated in either group, including among women with large breast volumes. Conclusion: Hypofractionated breast radiotherapy is well tolerated when treating patients in the prone position, even among those with large breast volumes. Breast IMRT significantly improves dosimetry but yields only a modest

  6. Major Late Toxicities After Conformal Radiotherapy for Nasopharyngeal Carcinoma-Patient- and Treatment-Related Risk Factors

    International Nuclear Information System (INIS)

    Lee, Anne W.M.; Ng, W.T.; Hung, W.M.; Choi, C.W.; Tung, Raymond; Ling, Y.H.; Cheng, Peter T.C.; Yau, T.K.; Chang, Amy T.Y.; Leung, Samuel K.C.; Lee, Michael C.H.; Bentzen, Soren M.

    2009-01-01

    Purpose: To retrospectively analyze the factors affecting late toxicity for nasopharyngeal carcinoma. Methods and Materials: Between 1998 and 2003, 422 patients were treated with a conformal technique with 2-Gy daily fractions to a total dose of 70 Gy. Conventional fractionation (5 fractions weekly) was used in 232 patients and accelerated fractionation (6 fractions weekly) in 190 patients. One hundred seventy-one patients were treated with the basic radiotherapy course alone (Group 1), 55 patients had an additional boost of 5 Gy in 2 fractions (Group 2), and 196 patients underwent concurrent cisplatin-based chemotherapy (Group 3). Results: The 5-year overall toxicity rate was significantly greater in Group 3 than in Group 1 (37% vs. 27%, p = 0.009). Although the overall rate in Group 2 was not elevated (28% vs. 27%, p = 0.697), a significant increase in temporal lobe necrosis was observed (4.8% vs. 0%, p = 0.015). Multivariate analyses showed that age and concurrent chemotherapy were significant factors. The hazard ratio of overall toxicity attributed to chemotherapy was 1.99 (95% confidence interval, 1.32-2.99, p = 0.001). The mean radiation dose to the cochlea was another significant factor affecting deafness, with a hazard ratio of 1.03 (95% confidence interval, 1.01-1.05, p = 0.005) per 1-Gy increase. The cochlea that received >50 Gy had a significantly greater deaf rate (Group 1, 18% vs. 7%; and Group 3, 22% vs. 14%). Conclusion: The therapeutic margin for nasopharyngeal carcinoma is extremely narrow, and a significant increase in brain necrosis could result from dose escalation. The significant factors affecting the risk of deafness included age, concurrent chemoradiotherapy, and greater radiation dose to the cochlea

  7. On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator.

    Science.gov (United States)

    Putha, Suman Kumar; Saxena, P U; Banerjee, S; Srinivas, Challapalli; Vadhiraja, B M; Ravichandran, Ramamoorthy; Joan, Mary; Pai, K Dinesh

    2016-01-01

    Transmission of radiation fluence through patient's body has a correlation to the planned target dose. A method to estimate the delivered dose to target volumes was standardized using a beam level 0.6 cc ionization chamber (IC) positioned at electronic portal imaging device (EPID) plane from the measured transit signal (S t ) in patients with cancer of uterine cervix treated with three-dimensional conformal radiotherapy (3DCRT). The IC with buildup cap was mounted on linear accelerator EPID frame with fixed source to chamber distance of 146.3 cm, using a locally fabricated mount. S t s were obtained for different water phantom thicknesses and radiation field sizes which were then used to generate a calibration table against calculated midplane doses at isocenter (D iso,TPS ), derived from the treatment planning system. A code was developed using MATLAB software which was used to estimate the in vivo dose at isocenter (D iso,Transit ) from the measured S t s. A locally fabricated pelvic phantom validated the estimations of D iso,Transit before implementing this method on actual patients. On-line dose estimations were made (3 times during treatment for each patient) in 24 patients. The D iso,Transit agreement with D iso,TPS in phantom was within 1.7% and the mean percentage deviation with standard deviation is -1.37% ±2.03% ( n = 72) observed in patients. Estimated in vivo dose at isocenter with this method provides a good agreement with planned ones which can be implemented as part of quality assurance in pelvic sites treated with simple techniques, for example, 3DCRT where there is a need for documentation of planned dose delivery.

  8. Electrochemical Techniques in Textile Processes and Wastewater Treatment

    Directory of Open Access Journals (Sweden)

    Mireia Sala

    2012-01-01

    Full Text Available The textile industry uses the electrochemical techniques both in textile processes (such as manufacturing fibers, dyeing processes, and decolorizing fabrics and in wastewaters treatments (color removal. Electrochemical reduction reactions are mostly used in sulfur and vat dyeing, but in some cases, they are applied to effluents discoloration. However, the main applications of electrochemical treatments in the textile sector are based on oxidation reactions. Most of electrochemical oxidation processes involve indirect reactions which imply the generation of hypochlorite or hydroxyl radical in situ. These electrogenerated species are able to bleach indigo-dyed denim fabrics and to degrade dyes in wastewater in order to achieve the effluent color removal. The aim of this paper is to review the electrochemical techniques applied to textile industry. In particular, they are an efficient method to remove color of textile effluents. The reuse of the discolored effluent is possible, which implies an important saving of salt and water (i.e., by means of the “UVEC Cell”.

  9. Conformational analysis by intersection: CONAN.

    Science.gov (United States)

    Smellie, Andrew; Stanton, Robert; Henne, Randy; Teig, Steve

    2003-01-15

    As high throughput techniques in chemical synthesis and screening improve, more demands are placed on computer assisted design and virtual screening. Many of these computational methods require one or more three-dimensional conformations for molecules, creating a demand for a conformational analysis tool that can rapidly and robustly cover the low-energy conformational spaces of small molecules. A new algorithm of intersection is presented here, which quickly generates (on average heuristics are applied after intersection to generate a small representative collection of conformations that span the conformational space. In a study of approximately 97,000 randomly selected molecules from the MDDR, results are presented that explore these conformations and their ability to cover low-energy conformational space. Copyright 2002 Wiley Periodicals, Inc. J Comput Chem 24: 10-20, 2003

  10. New Technique for the Treatment of Buried Penis in Children.

    Science.gov (United States)

    Liu, Feng; Lin, Tao; He, Dawei; Wei, Guanghui; Liu, Junhong; Liu, Xing; Hua, Yi; Zhang, Deying; Lu, Peng; Wu, Shengde; Li, Xuliang

    2016-02-01

    To present our treatment experience of buried penis, which has no consensus therapeutic technique for all cases of buried penis, by using a new technique for the repair of this condition, in which the approach is through the ventral penile root. We performed a retrospective review of 153 patients (median age: 6.5 years) who underwent repair of a buried penis between March 2005 and March 2013. The technique involves the creation of a wedge-shaped cut of the ventral penile skin, followed by fixation of the subcutaneous penile skin at the base of the degloved penis to the Buck fascia at the 2- and 10-o'clock positions. The ventral outer preputial skin is split down the midline, and the dorsal inner preputial skin is cut with oblique incision. All patients were followed for an average of 12 months after repair. Other than 2 cases (1.3%) of trapped penis with a ring of scar tissue, which required subsequent excision, there were no complications and the cosmetic appearance was satisfactory. The described ventral penile approach is a simple and effective procedure with good cosmetic outcomes and few complications. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Applications of one-dimensional or two-dimensional nuclear magnetic resonance to the structural and conformational study of oligosaccharides. Design and adjustment of new techniques

    International Nuclear Information System (INIS)

    Berthault, Patrick

    1988-01-01

    Oligosaccharides are natural compounds of huge importance as they intervene in all metabolic processes of cell life. Before the determination of structure-activity relationships, a precise knowledge of their chemical nature is therefore required. Thus, this research thesis aims at describing various experiments of high resolution nuclear magnetic resonance (NMR), and at demonstrating their applications on four oligosaccharides. After a brief description of NMR principles by using a conventional description and also a formalism derived from quantum mechanics, the author outlines the weaknesses of old NMR techniques, and introduces new techniques by using scalar couplings, by processing magnetization transfers with one-dimensional hetero-nuclear experiments. General principles of two-dimensional experiments are then presented and developed in terms of simple correlations, multiple correlations, correlations via double quantum coherencies. Experiments with light water are then described, and different experiments are performed to determine the structure and conformation of each unit. Bipolar interactions are then addressed to highlight proximities between atoms [fr

  12. Treatment Planning Study to Determine Potential Benefit of Intensity-Modulated Radiotherapy Versus Conformal Radiotherapy for Unresectable Hepatic Malignancies

    International Nuclear Information System (INIS)

    Eccles, Cynthia L.; Bissonnette, Jean-Pierre; Craig, Tim; Taremi, Mojgan; Wu Xia; Dawson, Laura A.

    2008-01-01

    Purpose: To compare intensity-modulated radiotherapy (IMRT) with conformal RT (CRT) for hypofractionated isotoxicity liver RT and explore dose escalation using IMRT for the same/improved nominal risk of liver toxicity in a treatment planning study. Methods and Materials: A total of 26 CRT plans were evaluated. Prescription doses (24-54 Gy within six fractions) were individualized on the basis of the effective liver volume irradiated maintaining ≤5% risk of radiation-induced liver disease. The dose constraints included bowel (0.5 cm 3 ) and stomach (0.5 cm 3 ) to ≤30 Gy, spinal cord to ≤25 Gy, and planning target volume (PTV) to ≤140% of the prescribed dose. Two groups were evaluated: (1) PTV overlapping or directly adjacent to serial functioning normal tissues (n = 14), and (2) the liver as the dose-limiting normal tissue (n = 12). IMRT plans using direct machine parameter optimization maintained the CRT plan beam arrangements, an estimated radiation-induced liver disease risk of 5%, and underwent dose escalation, if all normal tissue constraints were maintained. Results: IMRT improved PTV coverage in 19 of 26 plans (73%). Dose escalation was feasible in 9 cases by an average of 3.8 Gy (range, 0.6-13.2) in six fractions. Three of seven plans without improved PTV coverage had small gross tumor volumes (≤105 cm 3 ) already receiving 54 Gy, the maximal prescription dose allowed. In the remaining cases, the PTV range was 9.6-689 cm 3 ; two had overlapped organs at risk; and one had four targets. IMRT did not improve these plans owing to poor target coverage (n = 2) and nonliver (n = 2) dose limits. Conclusion: Direct machine parameter optimization IMRT improved PTV coverage while maintaining normal tissue tolerances in most CRT liver plans. Dose escalation was possible in a minority of patients

  13. Effects of three-dimensional conformal radiotherapy, indensity modulated radiotherapy, and conventional radiotherapy ON treatment of esophageal cancer

    Directory of Open Access Journals (Sweden)

    Jian-Jun Han

    2016-07-01

    Full Text Available Objective: To compare the irradiation volume, short-term and long-term efficacy of conventional radiotherapy (CR, three-dimensional conformal radiotherapy (3D-CRT, and indensity modulated radiotherapy (IMRT in the treatment of esophageal cancer. Methods: A retrospective analysis method was adopted. The patients were divided into CR group (n=42, 3D-CRT group (n=45, and IMRT group (n=40. A follow-up visit was paid to collect the short-term and long-term efficacy, and the occurrence of adverse reactions. The gross tumor voluem (GTV, clinical target volume (CTV, planning target volume (PTV, and irradiation volume of organs (bilateral lungs, spinal cord, and heart at risk (OAR in the three groups were compared. Results: It was found by target volume comparison that the mean values of GTV, CTV, and PTV in the three groups were significantly increased (P0.05. The occurrence rate of adverse reactions in 3D-CRT group and IMRT group was significantly lower than that in CR group (P0.05. The difference of 1-year survival rate among the three groups was not statistically significant (P=0.144, but 3-year and 5-year survival rates in 3D-CRT group and IMRT group were significantly higher than those in CR group (P<0.05. Conclusions: 3D-CRT and IMRT can significantly enhance the short-term and long-term efficacy for esophageal cancer patients, and alleviate the radioactive damage; therefore, they are deserved to be widely recommended in the clinic.

  14. Performance assessment techniques for groundwater recovery and treatment systems

    Energy Technology Data Exchange (ETDEWEB)

    Kirkpatrick, G.L. [Environmental Resources Management, Inc., Exton, PA (United States)

    1993-03-01

    Groundwater recovery and treatment (pump and treat systems) continue to be the most commonly selected remedial technology for groundwater restoration and protection programs at hazardous waste sites and RCRA facilities nationwide. Implementing a typical groundwater recovery and treatment system includes the initial assessment of groundwater quality, characterizing aquifer hydrodynamics, recovery system design, system installation, testing, permitting, and operation and maintenance. This paper focuses on methods used to assess the long-term efficiency of a pump and treat system. Regulatory agencies and industry alike are sensitive to the need for accurate assessment of the performance and success of groundwater recovery systems for contaminant plume abatement and aquifer restoration. Several assessment methods are available to measure the long-term performance of a groundwater recovery system. This paper presents six assessment techniques: degree of compliance with regulatory agency agreement (Consent Order of Record of Decision), hydraulic demonstration of system performance, contaminant mass recovery calculation, system design and performance comparison, statistical evaluation of groundwater quality and preferably, integration of the assessment methods. Applying specific recovery system assessment methods depends upon the type, amount, and quality of data available. Use of an integrated approach is encouraged to evaluate the success of a groundwater recovery and treatment system. The methods presented in this paper are for engineers and corporate management to use when discussing the effectiveness of groundwater remediation systems with their environmental consultant. In addition, an independent (third party) system evaluation is recommended to be sure that a recovery system operates efficiently and with minimum expense.

  15. Conformal Gravity

    International Nuclear Information System (INIS)

    Hooft, G.

    2012-01-01

    The dynamical degree of freedom for the gravitational force is the metric tensor, having 10 locally independent degrees of freedom (of which 4 can be used to fix the coordinate choice). In conformal gravity, we split this field into an overall scalar factor and a nine-component remainder. All unrenormalizable infinities are in this remainder, while the scalar component can be handled like any other scalar field such as the Higgs field. In this formalism, conformal symmetry is spontaneously broken. An imperative demand on any healthy quantum gravity theory is that black holes should be described as quantum systems with micro-states as dictated by the Hawking-Bekenstein theory. This requires conformal symmetry that may be broken spontaneously but not explicitly, and this means that all conformal anomalies must cancel out. Cancellation of conformal anomalies yields constraints on the matter sector as described by some universal field theory. Thus black hole physics may eventually be of help in the construction of unified field theories. (author)

  16. Radiosurgery with flattening-filter-free techniques in the treatment of brain metastases. Plan comparison and early clinical evaluation

    International Nuclear Information System (INIS)

    Rieber, J.; Tonndorf-Martini, E.; Schramm, O.; Rhein, B.; Stefanowicz, S.; Lindel, K.; Debus, J.; Rieken, S.; Kappes, J.; Hoffmann, H.

    2016-01-01

    Radiosurgical treatment of brain metastases is well established in daily clinical routine. Utilization of flattening-filter-free beams (FFF) may allow for more rapid delivery of treatment doses and improve clinical comfort. Hence, we compared plan quality and efficiency of radiosurgery in FFF mode to FF techniques. Between November 2014 and June 2015, 21 consecutive patients with 25 brain metastases were treated with stereotactic radiosurgery (SRS) in FFF mode. Brain metastases received dose-fractionation schedules of 1 x 20 Gy or 1 x 18 Gy, delivered to the conformally enclosing 80 % isodose. Three patients with critically localized or large (>3 cm) brain metastases were treated with 6 x 5 Gy. Plan quality and efficiency were evaluated by analyzing conformity, dose gradients, dose to healthy brain tissue, treatment delivery time, and number of monitor units. FFF plans were compared to those using the FF method, and early clinical outcome and toxicity were assessed. FFF mode resulted in significant reductions in beam-on time (p [de

  17. The treatment of nonpalpable PSA-detected adenocarcinoma of the prostate with 3-dimensional conformal radiation therapy

    International Nuclear Information System (INIS)

    Horwitz, Eric M.; Hanlon, Alexandra L.; Pinover, Wayne H.; Hanks, Gerald E.

    1998-01-01

    Purpose: We reviewed our institution's experience treating patients with nonpalpable PSA-detected prostate cancer with three-dimensional conformal radiation therapy (3DCRT) to determine prognostic factors that predict for biochemical-free survival (bNED) control and present the bNED control rates. Methods and Materials: Between May 1, 1990 and November 30, 1994, 160 patients with nonpalpable PSA-detected prostate cancer received 3DCRT at Fox Chase Cancer Center (median total dose 73 Gy; range: 67-78 Gy). bNED failure was defined as three consecutive increases in posttreatment PSA after achieving a nadir. bNED failure was recorded as the time midway between the nadir and the first consecutive rising PSA. Five-year actuarial rates of bNED control were calculated for pretreatment PSA (0-9.9 vs. 10-19.9 vs. ≥ 20 ng/ml), Gleason score (2-6 vs. 7-10), treatment field size (prostate vs. small pelvis), age ( 73 Gy) using Kaplan-Meier methods and compared using the Log rank test. The Cox model was used to multivariately establish independent predictors based on significant univariate factors. Median follow-up was 39 months (range: 2-84 months). Results: The 5-year actuarial rate of bNED control was 86% for the entire group of patients. The Cox Proportional Hazards model demonstrated that pretreatment PSA was an independent predictor of bNED control. Treatment field size was marginally predictive. There was no difference in bNED control when patients were stratified by the number of lobes positive for disease. Statistically different rates of bNED control were seen when the patients with nonpalpable disease were univariately compared to T2b and T2c patients. Three patients experienced Grade 3-4 genitourinary (GU) toxicity and 3 patients experienced Grade 3-4 gastrointestinal (GI) toxicity. Conclusions: Patients with nonpalpable PSA-detected prostate cancer can be effectively treated with 3DCRT with minimal morbidity and high rates of bNED control at 5 years. Pretreatment

  18. The Importance of the Conformality, Heterogeneity, and Gradient Indices in Evaluating Gamma Knife Radiosurgery Treatment Plans for Intracranial Meningiomas

    International Nuclear Information System (INIS)

    Balagamwala, Ehsan H.; Suh, John H.; Barnett, Gene H.; Khan, Mohammad K.; Neyman, Gennady; Cai, Rong S.; Vogelbaum, Michael A.; Novak, Eric; Chao, Samuel T.

    2012-01-01

    Purpose: To investigate the relationship between the conformality index (CIn), heterogeneity index (HIn), and gradient index (GIn) and the development of toxicity in patients treated with Gamma Knife radiosurgery (GKRS) for intracranial meningiomas. Methods and Materials: Treatment records of patients treated from 1997 to 2009 with at least 6 months of follow-up were reviewed. The following parameters were collected: CIn, HIn, GIn (ratio of the volume receiving half the prescription isodose to the volume receiving the full prescription isodose), brainstem (BS) maximum dose (MD), BS volume receiving ≥12 Gy (V12), optic apparatus (OA) MD, OA V8 Gy, OA V10, number of isocenters, number of isocenters outside target volume, and the occurrence of six toxicities. Univariate and multivariate logistic regression modeling were used for analysis. Results: This study included 145 patients (148 meningiomas) with a median follow-up time of 27 months (range, 6–113.9 months). The majority of meningiomas were located in the skull base (53%). The median prescription dose was 13 Gy (range, 10–24 Gy) to the 51.50% (range, 50–92%) isodose. A lower HIn was correlated with a higher GIn (p = 0.007). CIn was not associated with any toxicity. Higher HIn was associated with the development of dizziness (odds ratio [OR] 1.9; p = 0.02), whereas a lower GIn was associated with motor deficits (OR 0.38; p = 0.04) and auditory changes (OR 0.59; p = 0.04). The OA MD, V8, and V12 were not associated with visual changes, but visual changes were associated with a higher number of isocenters outside the target volume (OR 1.93; p = 0.07). BS V12 was correlated with the development of auditory changes (OR 1.05; p = 0.05), whereas patients with higher BS MD tended to have increased toxicity. Conclusions: Close attention must be paid to all three indices (CIn, HIn, GIn) when optimal treatment plans are determined. We recommend that the target CIn should be ≤2.0, the HIn ≤2.0, and the GIn ≥3

  19. Treatment of peat bogs harvested by deep digging technique

    International Nuclear Information System (INIS)

    Hoernsten, L.

    1992-06-01

    The aim of this study is to describe how peat bogs harvested by deep digging technique can be treated after harvesting has come to an end. The study points out treatment methods, how the treatments are carried out and to indicate the most appropriate method of harvest for optimum results. Costs and benefits are calculated for the methods involving cultivation. The knowledge gained from traditional peat harvesting technique indicate forestry, energy wood production and establishment of ponds as possible alternatives. Energy grass cultivation and establishments of game parks have not been tested. but are assumed to be viable on suitable sites. Establishment of duck ponds are also possible, even though conditions for these are better on firm ground. In this study spruce is estimated to produce 200 cubic meters during 105 year whilst pine produces 300 cubic meters. Calculations for pine and spruce estimate costs of respectively 17000 and 18000 SEK per hectare after 105 years. Energy wood production is estimated to be 11.6 tons dry matter per hectare and year which gives a net cost of 19000 SEK per hectare. Similarly energy grass cultivation results in an average annual harvest of 6.5 ton dry matter and a cost of 59000 SEK per hectare. If the results are applied to three specific cases, then forest cultivation and establishment of ponds are possible in all cases. Neither energy wood nor energy grass are appropriate in any of the three regions. At the particular site for this study all methods mentioned are possible. Depending on whether draining leads to a high or low water table, the most appropriate course would be the establishment of a pond respectively a game park of forest cultivation. (59 refs., 12 tabs., 4 figs.)

  20. Optimized evaporation technique for leachate treatment: Small scale implementation.

    Science.gov (United States)

    Benyoucef, Fatima; Makan, Abdelhadi; El Ghmari, Abderrahman; Ouatmane, Aziz

    2016-04-01

    This paper introduces an optimized evaporation technique for leachate treatment. For this purpose and in order to study the feasibility and measure the effectiveness of the forced evaporation, three cuboidal steel tubs were designed and implemented. The first control-tub was installed at the ground level to monitor natural evaporation. Similarly, the second and the third tub, models under investigation, were installed respectively at the ground level (equipped-tub 1) and out of the ground level (equipped-tub 2), and provided with special equipment to accelerate the evaporation process. The obtained results showed that the evaporation rate at the equipped-tubs was much accelerated with respect to the control-tub. It was accelerated five times in the winter period, where the evaporation rate was increased from a value of 0.37 mm/day to reach a value of 1.50 mm/day. In the summer period, the evaporation rate was accelerated more than three times and it increased from a value of 3.06 mm/day to reach a value of 10.25 mm/day. Overall, the optimized evaporation technique can be applied effectively either under electric or solar energy supply, and will accelerate the evaporation rate from three to five times whatever the season temperature. Copyright © 2016. Published by Elsevier Ltd.

  1. Modified technique of the treatment for proximal tibiofibular joint dislocation

    Directory of Open Access Journals (Sweden)

    Gvozdenović Nemanja

    2017-01-01

    Full Text Available Introduction. Dislocation of the proximal tibiofibular joint (PTFJ is a rare injury. The diagnosis requires an accurate history of the mechanism and symptoms of the injury, and adequate clinical and radiographic evaluation of both knees. In the literature there is no larger series, only several cases of PTFJ dislocation treated by different methods have been published so far. The aim of the study was to present a modified technique for the treatment of the unstable PTFJ that results in faster recovery of the patient. Case report. A 24-year-old football player was injured at the beginning of training; when tackling the ball he felt a sharp pain in his right knee. He was immediately brought to the Emergency Center of Vojvodina and diagnosed with anterolateral dislocation of the PTFJ. Close reduction in general anesthesia was tried but we failed and then open reduction and internal fixation (ORIF were performed with a single three cortical screw. We preferred not to immobilise the knee after the procedure and immediately employed passive and active exercises in the knee, without bearing weight to the injured leg. After 6 weeks we removed the screw and gave full weight support to the leg and continued physical treatment. Conclusion. In case of acute PTFJ dislocation, the first method of choice is closed reduction in sedation or general anesthesia. If closed reduction fails, ORIF must be performed. ORIF without immobilization and early start of physical therapy lead to the rapid return to sports activities

  2. Comparison of cardiac and lung doses for breast cancer patients with free breathing and deep inspiration breath hold technique in 3 dimensional conformal radiotherapy - a dosimetric study

    Science.gov (United States)

    Raj Mani, Karthick; Poudel, Suresh; Maria Das, K. J.

    2017-12-01

    Purpose: To investigate the cardio-pulmonary doses between Deep Inspiration Breath Hold (DIBH) and Free Breathing (FB) technique in left sided breast irradiation. Materials & Methods: DIBH CT and FB CT were acquired for 10 left sided breast patients who underwent whole breast irradiation with or without nodal irradiation. Three fields single isocenter technique were used for patients with node positive patients along with two tangential conformal fields whereas only two tangential fields were used in node negative patients. All the critical structures like lungs, heart, esophagus, thyroid, etc., were delineated in both DIBH and FB scan. Both DIBH and FB scans were fused with the Dicom origin as they were acquired with the same Dicom coordinates. Plans were created in the DIBH scan for a dose range between 50 Gy in 25 fractions. Critical structures doses were recorded from the Dose Volume Histogram for both the DIBH and FB data set for evaluation. Results: The average mean heart dose in DIBH vs FB was 13.18 Gy vs 6.97 Gy, (p = 0.0063) significantly with DIBH as compared to FB technique. The relative reduction in average mean heart dose was 47.12%. The relative V5 reduced by 14.70% (i.e. 34.42% vs 19.72%, p = 0.0080), V10 reduced by 13.83% (i.e. 27.79 % vs 13.96%, p = 0.0073). V20 reduced by 13.19% (i.e. 24.54 % vs 11.35%, p = 0.0069), V30 reduced by 12.38% (i.e. 22.27 % vs 9.89 %, p = 0.0073) significantly with DIBH as compared to FB. The average mean left lung dose reduced marginally by 1.43 Gy (13.73 Gy vs 12.30 Gy, p = 0.4599) but insignificantly with DIBH as compared to FB. Other left lung parameters (V5, V10, V20 and V30) shows marginal decreases in DIBH plans compare to FB plans. Conclusion: DIBH shows a substantial reduction of cardiac doses but slight and insignificant reduction of pulmonary doses as compared with FB technique. Using the simple DIBH technique, we can effectively reduce the cardiac morbidity and at the same time radiation induced lung

  3. Economics of wastewater treatment in GTL plant using spray technique

    Energy Technology Data Exchange (ETDEWEB)

    Enyi, G.C.; Nasr, G.G.; Burby, M. [University of Salford, Manchester, M5 4WT (United Kingdom)

    2013-07-01

    In a Gas-to-liquid (GTL) plant, significant quantities of CO2 and reaction water are produced and various chemicals are used as intermediate treatment chemicals. The reaction water is contaminated by these chemicals which impair the pH and the related properties of the water. The pH has to be controlled in the effluent treatment unit before the water is re-used or released to the environment. The overall aim of this investigation is to create a novel technique to address the problem of waste water treatment in GTL plants which will assist in the reduction of greenhouse gas (CO2) emissions into the atmosphere. A laboratory-scale effluent neutralisation unit for pH control utilising gas injectors was designed and built. The unit used the CO2 produced as a by-product of GTL process as wastewater treatment chemical instead of the conventional Sulphuric acid. The quality of wastewater after treatment with CO2 met the standards set by the state regulatory agency. The economics of the new process shows a better payout period of 3.6 years for capital investment of $1,645 Million compared to 4.7 years for an existing plant layout with capital investment of $1,900 Million. The effects of increase in plant capacity showed a lower payback back of 2.8 years for plant capacity of 140,000 barrels/day (22258 m3/day), 3.6 years for 34,000 barrels/day and 6.0 years for 12,500 barrels/day (1987 m3/day) plant capacity. The sensitivity analysis using crystal ball simulator with 'Microsoft Excel' shows that the annual revenue has the greatest effects on the NPV of the plant than the CAPEX and inflation rate. Apart from the environmental benefits the process generates by reducing CO2 emissions into the atmosphere, the study also concludes that the replacement of conventional Sulphuric acid (H2SO4) unit with CO2 improves the economics of the plant.

  4. Sediment remediation treatment techniques for the Venice industrial canals

    Energy Technology Data Exchange (ETDEWEB)

    Pippa, R.; Scanferla, P.; Cammarata, F.; Zampieri, L.; Carlon, C. [Consorzio Venezia Ricerche (Italy); Pavoni, B. [Ca' Foscari University of Venice (Italy). Dept. of Environmental Sciences; Pannocchia, G. [Venezia Technologie SpA, Venice (Italy); Hreglich, S. [Stazione Sperimentale del Vetro, Venice (Italy); Avezzu, F. [Depuracque Impianti srl, Venice (Italy)

    2003-07-01

    The main objective of SeRTech project (Sediment Remediation Technologies) is to develop an integrated cost-effective treatment system to address heterogeneous contamination and matrixes, such as those of Venice lagoon dredged materials. Seven treatment techniques, selected over a large array, have been tested: Thermal Desorption. A preliminary set of isothermal treatments at different temperatures was performed to evaluated the losses of organic and the most volatile metals (such as Pb and As). An almost full volatilisation of organic compounds was observed at temperatures ranging between 200 and 300 C. Chemical stabilization-solidification. Depuracque Impianti srl process uses innovative patented additives (polimers and superplasticizers) to immobilize heavy metals into cement pellets. Solvent extraction. Organic contaminants such as PAHs and PCBs were extracted from sediments by using ethyl acetate. The results showed that solvent extraction obtained high efficiency in removal of PAHs and other organic contaminants. Immobilization of heavy metals employing sulfate-reducing bacteria. High Gradient Magnetic Separation (HGMS). Sulfate reducing bacteria (SBR) produce an iron sulfide containing biomass with a high capability to adsorbe hevy metals and some organic compounds. This biomass can be separated through a high gradient magnetic field removing a substantial fraction of contaminants. Vitrification. Sediment was mixed with other inorganic wastes (glass cullet, feldsphatic tailings) and low amounts of row material to obtain an inert glass, which in turn can be recycled into other useful products, for example glass fibres, foam glass and glass ceramics. Phytoremediation. Phragmites australis (Cav.), Trin; Juncus Iacustrus, Arthrocnmemum fruticosum, Spartina maritima, Helianthus annuus L., Zea mais L., Brassica napus L., Brassica juncea L. have been selected to verify limit and efficiency of phytoextraction for heavy metals (Zn, Pb, Hg, Cd, As, Ni). Not only

  5. Treatment of primany hepatic carcinoma with three-dimensional conformal radiation therapy combined with transcatheter arterial chemoembolization

    International Nuclear Information System (INIS)

    Wu Li; Wen Xiaoping; Huang Wei

    2006-01-01

    Objective: To evaluate the effects of three-dimensional conformal radiation therapy (3DCRT) combined with transcatheter arterial chemoembolization (TACE) on stage m/IV primary hepatic carcinoma. Methods: Eighty cases of stage III/IV primary hepatic carcinoma were randomly divided into two groups: 40 cases treated with three-dimensional conformal radiation therapy combined with transcatheter arterial chemoembolization (3DCRT + TACE group) and 40 cases treated with three-dimensional conformal radiation therapy associated with hepatic arterial infusion chemotherapy (3DCRT +HAI group). Results: The response rates were 75% and 45% in 3DCRT + TACE group and 3DCRT + HAI group, respectively; and the difference between the two groups was statistically significant (P 0.05), The 0.5-, 1- and 2-year survival rates were 73% , 45% and 28% in 3DCRT + TACE group, and 45%, 25% and 13% in 3DCRT + HAI group, respectively; and the difference between the two groups was statistically significant (P 0.05). Conclusion: Three-dimensional conformal radiation therapy combined with transcatheter arterial chemoembolization improved prognosis of stage III/IV primary hepatic carcinoma. (authors)

  6. Conkiss: Conformal Kidneys Sparing 3D Noncoplanar Radiotherapy Treatment for Pancreatic Cancer As an Alternative to IMRT

    International Nuclear Information System (INIS)

    Sebestyen, Zsolt; Kovacs, Peter; Gulyban, Akos; Farkas, Robert; Bellyei, Szabolcs; Liposits, Gabor; Szigeti, Andras; Esik, Olga; Derczy, Katalin; Mangel, Laszlo

    2011-01-01

    When treating pancreatic cancer using standard (ST) 3D conformal radiotherapy (3D-CRT) beam arrangements, the kidneys often receive a higher dose than their probable tolerance limit. Our aim was to elaborate a new planning method that-similarly to IMRT-effectively spares the kidneys without compromising the target coverage. Conformal kidneys sparing (CONKISS) 5-field, noncoplanar plans were compared with ST plans for 23 consecutive patients retrospectively. Optimal beam arrangements were used consisting of a left- and right-wedged beam-pair and an anteroposterior beam inclined in the caudal direction. The wedge direction determination (WEDDE) algorithm was developed to adjust the adequate direction of wedges. The aimed organs at risk (OARs) mean dose limits were: kidney <12 Gy, liver <25 Gy, small bowels <30 Gy, and spinal cord maximum <45 Gy. Conformity and homogeneity indexes with z-test were used to evaluate and compare the different planning approaches. The mean dose to the kidneys decreased significantly (p < 0.05): left kidney 7.7 vs. 10.7 Gy, right kidney 9.1 vs. 11.7 Gy. Meanwhile the mean dose to the liver increased significantly (18.1 vs. 15.0 Gy). The changes in the conformity, homogeneity, and in the doses to other OARs were not significant. The CONKISS method balances the load among the OARs and significantly reduces the dose to the kidneys, without any significant change in the conformity and homogeneity. Using 3D-CRT the CONKISS method can be a smart alternative to IMRT to enhance the possibility of dose escalation.

  7. A computer-controlled conformal radiotherapy system I: overview

    International Nuclear Information System (INIS)

    Fraass, Benedick A.; McShan, Daniel L.; Kessler, Marc L.; Matrone, Gwynne M.; Lewis, James D.; Weaver, Tamar A.

    1995-01-01

    Purpose: Equipment developed for use with computer-controlled conformal radiotherapy (CCRT) treatment techniques, including multileaf collimators and/or computer-control systems for treatment machines, are now available. The purpose of this work is to develop a system that will allow the safe, efficient, and accurate delivery of CCRT treatments as routine clinical treatments, and permit modifications of the system so that the delivery process can be optimized. Methods and Materials: The needs and requirements for a system that can fully support modern computer-controlled treatment machines equipped with multileaf collimators and segmental or dynamic conformal therapy capabilities have been analyzed and evaluated. This analysis has been used to design and then implement a complete approach to the delivery of CCRT treatments. Results: The computer-controlled conformal radiotherapy system (CCRS) described here consists of a process for the delivery of CCRT treatments, and a complex software system that implements the treatment process. The CCRS system described here includes systems for plan transfer, treatment delivery planning, sequencing of the actual treatment delivery process, graphical simulation and verification tools, as well as an electronic chart that is an integral part of the system. The CCRS system has been implemented for use with a number of different treatment machines. The system has been used clinically for more than 2 years to perform CCRT treatments for more than 200 patients. Conclusions: A comprehensive system for the implementation and delivery of computer-controlled conformal radiation therapy (CCRT) plans has been designed and implemented for routine clinical use with multisegment, computer-controlled, multileaf-collimated conformal therapy. The CCRS system has been successfully implemented to perform these complex treatments, and is considered quite important to the clinical use of modern computer-controlled treatment techniques

  8. Dosimetric quality assurance of highly conformal external beam treatments: from 2D phantom comparisons to 4D patient dose reconstruction

    International Nuclear Information System (INIS)

    Feygelman, V; Nelms, B

    2013-01-01

    As IMRT technology continues to evolve, so do the dosimetric QA methods. A historical review of those is presented, starting with longstanding techniques such as film and ion chamber in a phantom and progressing towards 3D and 4D dose reconstruction in the patient. Regarding patient-specific QA, we envision that the currently prevalent limited comparison of dose distributions in the phantom by γ-analysis will be eventually replaced by clinically meaningful patient dose analyses with improved sensitivity and specificity. In a larger sense, we envision a future of QA built upon lessons from the rich history of ''quality'' as a science and philosophy. This future will aim to improve quality (and ultimately reduce cost) via advanced commissioning processes that succeed in detecting and rooting out systematic errors upstream of patient treatment, thus reducing our reliance on, and the resource burden associated with, per-beam/per-plan inspection.

  9. Dosimetric quality assurance of highly conformal external beam treatments: from 2D phantom comparisons to 4D patient dose reconstruction

    Science.gov (United States)

    Feygelman, V.; Nelms, B.

    2013-06-01

    As IMRT technology continues to evolve, so do the dosimetric QA methods. A historical review of those is presented, starting with longstanding techniques such as film and ion chamber in a phantom and progressing towards 3D and 4D dose reconstruction in the patient. Regarding patient-specific QA, we envision that the currently prevalent limited comparison of dose distributions in the phantom by γ-analysis will be eventually replaced by clinically meaningful patient dose analyses with improved sensitivity and specificity. In a larger sense, we envision a future of QA built upon lessons from the rich history of "quality" as a science and philosophy. This future will aim to improve quality (and ultimately reduce cost) via advanced commissioning processes that succeed in detecting and rooting out systematic errors upstream of patient treatment, thus reducing our reliance on, and the resource burden associated with, per-beam/per-plan inspection.

  10. Development of a technique for environmental treatment by radiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myun Joo; Jin, J. H.; Jung, Y. D. and others

    2000-04-01

    This study was carried out for the development of pilot plant which can produce industrial water from effluent of sewage treatment plant by irradiation. As a basic study, the characteristics on decomposition of organic compounds, decoloration and sterilization of bacteria were evaluated. An additive mainly composed by sponge type of TiO{sub 2} was developed for reduction of irradiation dose and enhancement of removal efficiency of organic compounds. The optimum pilot plant was composed of sysem with gamma irradiation/ozone/additive/ion exchange. The effluent with BOD 20 ppm, COD 25 ppm and color 25 ADMI could be treated to less than 5 ppm and 5 ADMI under the irradiation of 5 kGy. The disinfection of microorganism also could be done perfectively under the same irradiation. A small amount of heavy metal ions and inorganic ions, nitrogen, contained in effluent were removed by ion exchanger. From the operation of pilot plant it could be concluded that irradiation technique can be a good method for the produce of industrial water from effluent.

  11. Surgical treatment of gynecomastia: mastectomy compared to liposuction technique.

    Science.gov (United States)

    Song, Yan-Ni; Wang, Yan-Bo; Huang, Rui; He, Xiao-Guang; Zhang, Jin-Feng; Zhang, Guo-Qiang; Ren, Yan-Lv; Pang, Jian-Hua; Pang, Da

    2014-09-01

    Gynecomastia is a benign enlargement of the male breast. Yet enlarged breasts cause anxiety, embarrassment, psychosocial discomfort, and fear of breast cancer. The aim of this study was to assess the experience of gynecomastia patients undergoing mastectomy and liposuction surgery. Seven hundred thirty-three patients were analyzed for age, chief complaint, position, grade, operation approach, biopsy, and complication between mastectomy group and liposuction group, from 1990 to 2010. Four hundred two patients (436 breasts) were treated with mastectomy and 331 patients (386 breasts) were treated with liposuction techniques. Three hundred thirty (82%) patients complained of breast lump and lump with pain in mastectomy group, and 204 (61%) patients complained of enlargement breast and enlargement with pain in liposuction group (P liposuction acquired pathologic diagnosis through fine needle aspiration and/or core biopsy (P liposuction group were 1.4% and 0.5%, respectively. There were no nipple/areola necrosis and scars in liposuction group. The surgical treatment of gynecomastia required an individual approach, depending on symptoms (lump or enlargement) and requirements of patients. Patients who chose mastectomy were looking for reassurance that their pathologic diagnosis was benign. The increase in the number of liposuction patients was reflected in our study because it was associated with superior esthetic results and few complications.

  12. NONVERBAL TREATMENT OF NEUROSIS—Techniques for General Practice

    Science.gov (United States)

    Batten, Charles T.

    1959-01-01

    “Psychosomatic medicine” does not demand that the general practitioner function as a psychiatrist; rather, it is a psychiatric orientation that can increase the effectiveness of purely medical treatment for such conditions as neuroses. The general practitioner to whom the patient turns may achieve permanent results with nonverbal techniques where formal psychotherapy would be impracticable or unacceptable. The first aim is to relieve pressure so that the patient can regain his mental balance and thereby his self-confidence. Arts, hobbies, sports, and the like can be prescribed rather specifically according to the patient's personality and needs. Nutrition can be improved simply at first by prescribing needed additions to diet rather than imposing restrictions. Vitamin deficiency may by itself be the cause of neurosis or more serious mental disease, whereas psychic stress by itself may create a need for additional vitamin intake. Hormone therapy may be extremely helpful but must be based on clear indication and limited to specific purposes. Since lack of sleep and rest quickly impairs mental function, it is important for neurotic persons to learn relaxation as a necessity for sleep. Sedatives may be used in a crisis but should be abandoned as soon as possible. With all drugs there are problems of excess and habituation. The least, the mildest, the shortest dosage is the ideal. The initial steps of psychotherapy are available to any physician: Establishing rapport, noting how complaints are stated, encouraging ventilation, winning confidence rather than immediate results. PMID:13638823

  13. Development of a technique for environmental treatment by radiation

    International Nuclear Information System (INIS)

    Lee, Myun Joo; Jin, J. H.; Jung, Y. D. and others

    2000-04-01

    This study was carried out for the development of pilot plant which can produce industrial water from effluent of sewage treatment plant by irradiation. As a basic study, the characteristics on decomposition of organic compounds, decoloration and sterilization of bacteria were evaluated. An additive mainly composed by sponge type of TiO 2 was developed for reduction of irradiation dose and enhancement of removal efficiency of organic compounds. The optimum pilot plant was composed of sysem with gamma irradiation/ozone/additive/ion exchange. The effluent with BOD 20 ppm, COD 25 ppm and color 25 ADMI could be treated to less than 5 ppm and 5 ADMI under the irradiation of 5 kGy. The disinfection of microorganism also could be done perfectively under the same irradiation. A small amount of heavy metal ions and inorganic ions, nitrogen, contained in effluent were removed by ion exchanger. From the operation of pilot plant it could be concluded that irradiation technique can be a good method for the produce of industrial water from effluent

  14. Technique for radiation treatment of exhaust gas due to combustion

    International Nuclear Information System (INIS)

    Machi, Sueo

    1978-01-01

    As the Japanese unique research in the field of preservation of environment, the technique to remove simultaneously sulphur dioxide and nitrogen oxides in exhaust gas using electron beam irradiation is noteworthy. This research was started by the experiment in the central research laboratory of Ebara Manufacturing Co., Ltd., in which it was found that the sulphur dioxide of initial concentration of 1,000 ppm was almost completely vanished when the exhaust gas of heavy oil combustion in a batch type vessel was irradiated for 9 minutes by electron beam. Based on this experiment, JAERI installed a continuous irradiation equipment with a large accelerator, and has investigated the effect of various parameters such as dose rate, irradiation temperature, total dose and agitation. This resulted in the remarkable finding that nitrogen oxides were also completely removed as well as sulphur dioxide when the exhaust gas containing both sulphur dioxide and nitrogen oxides was irradiated for a few seconds. In this case, if water of about 0.3% is added, removal rate of sulphur dioxide is greatly increased. The research group of University of Tokyo obtained other findings concerning removal rates. Then, after the pilot plant stage in Ebara Manufacturing Co., Ltd. from 1974, the test plant of exhaust gas treatment for a sintering machine, having the capacity of 3,000 Nm 3 /hr, has been constructed in Yawata Works of Nippon Steel Corp. This is now operating properly. (Wakatsuki, Y.)

  15. Use of benchmark dose-volume histograms for selection of the optimal technique between three-dimensional conformal radiation therapy and intensity-modulated radiation therapy in prostate cancer

    International Nuclear Information System (INIS)

    Luo Chunhui; Yang, Claus Chunli; Narayan, Samir; Stern, Robin L.; Perks, Julian; Goldberg, Zelanna; Ryu, Janice; Purdy, James A.; Vijayakumar, Srinivasan

    2006-01-01

    Purpose: The aim of this study was to develop and validate our own benchmark dose-volume histograms (DVHs) of bladder and rectum for both conventional three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), and to evaluate quantitatively the benefits of using IMRT vs. 3D-CRT in treating localized prostate cancer. Methods and Materials: During the implementation of IMRT for prostate cancer, our policy was to plan each patient with both 3D-CRT and IMRT. This study included 31 patients with T1b to T2c localized prostate cancer, for whom we completed double-planning using both 3D-CRT and IMRT techniques. The target volumes included prostate, either with or without proximal seminal vesicles. Bladder and rectum DVH data were summarized to obtain an average DVH for each technique and then compared using two-tailed paired t test analysis. Results: For 3D-CRT our bladder doses were as follows: mean 28.8 Gy, v60 16.4%, v70 10.9%; rectal doses were: mean 39.3 Gy, v60 21.8%, v70 13.6%. IMRT plans resulted in similar mean dose values: bladder 26.4 Gy, rectum 34.9 Gy, but lower values of v70 for the bladder (7.8%) and rectum (9.3%). These benchmark DVHs have resulted in a critical evaluation of our 3D-CRT techniques over time. Conclusion: Our institution has developed benchmark DVHs for bladder and rectum based on our clinical experience with 3D-CRT and IMRT. We use these standards as well as differences in individual cases to make decisions on whether patients may benefit from IMRT treatment rather than 3D-CRT

  16. Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques

    International Nuclear Information System (INIS)

    Nutting, Christopher M.; Rowbottom, Carl G.; Cosgrove, Vivian P.; Henk, J. Michael; Dearnaley, David P.; Robinson, Martin H.; Conway, John; Webb, Steve

    2001-01-01

    Background and purpose: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution. Materials and methods: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stem, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated. Results: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170 degree sign from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation. Conclusions: For patients with parotid gland tumours

  17. Evaluation of aluminum oxide dosimeters using OSL technique in dosimetry of clinical photon beams on volumetric modulated arc treatment

    International Nuclear Information System (INIS)

    Villani, Daniel

    2017-01-01

    Treatment using Volumetric Modulated Arc Radiation Therapy is the most modern modality of conformational radiotherapy so that, with the overlapping of several fields, the dose distributions provide a perfect conformation to the tumor, reducing the probability of complications in adjacent normal tissues. In this sense, many efforts are being invested to improve dose distribution compliance as well as the integration of imaging techniques for tumor screening and correction of inter and intrafraction variations. To this end, an intensive monitoring of the quality of the processes and a quality assurance program are fundamental for patient safety and compliance with current legislation; besides the use of different dosimetry methodologies for intercomparison and validation of the results. The aim of this study is to evaluate and compare the performance of aluminum oxide (Al_2O_3:C) OSL dosimeters manufactured by Landauer Inc. with those produced by Rexon™ in the dosimetry of high energy photon clinical bundles used in Volumetric Modulated Arc Therapy - (VMAT) using different simulating objects. The dosimeters were characterized for gamma radiation of the "6"0Co and for clinical photon beams of 6 MV typical of treatments by VMAT under conditions of electronic equilibrium and maximum dose respectively. Performance tests of the TL and OSL readers used and repeatability of the samples were evaluated. After all tests, the dosimeters were irradiated in the simulation of different radiotherapy treatments by VMAT and their responses compared to the planning system. All types of dosimeters presented satisfactory results in verifying the doses of this type of planning simulation. The Al_2O_3:C dosimeters presented compatible results and validated by the other dosimeters and ionization chamber. Regarding the best technique, the OSL InLight commercial system presents greater practicality and versatility for use and application in the clinical routine. (author)

  18. Conformality lost

    International Nuclear Information System (INIS)

    Kaplan, David B.; Lee, Jong-Wan; Son, Dam T.; Stephanov, Mikhail A.

    2009-01-01

    We consider zero-temperature transitions from conformal to nonconformal phases in quantum theories. We argue that there are three generic mechanisms for the loss of conformality in any number of dimensions: (i) fixed point goes to zero coupling, (ii) fixed point runs off to infinite coupling, or (iii) an IR fixed point annihilates with a UV fixed point and they both disappear into the complex plane. We give both relativistic and nonrelativistic examples of the last case in various dimensions and show that the critical behavior of the mass gap behaves similarly to the correlation length in the finite temperature Berezinskii-Kosterlitz-Thouless (BKT) phase transition in two dimensions, ξ∼exp(c/|T-T c | 1/2 ). We speculate that the chiral phase transition in QCD at large number of fermion flavors belongs to this universality class, and attempt to identify the UV fixed point that annihilates with the Banks-Zaks fixed point at the lower end of the conformal window.

  19. SU-E-T-346: Effect of Jaw Position On Dose to Critical Structures in 3-D Conformal Radiotherapy Treatment of Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Paudel, N; Han, E; Liang, X; Morrill, S; Zhang, X; Hardee, M; Penagaricano, J; Ratanatharathorn, V [Vaneerat, University of Arkansas for Medical Sciences, Little Rock, AR (United States)

    2015-06-15

    Purpose: Three-dimensional conformal therapy remains a valid and widely used modality for pancreatic radiotherapy treatment. It usually meets dose constraints on critical structures. However, careful positioning of collimation jaws can reduce dose to the critical structures. Here we investigate the dosimetric effect of jaw position in MLC-based 3-D conformal treatment planning on critical structures. Methods: We retrospectively selected seven pancreatic cancer patients treated with 3-D conformal radiotherapy. We started with treatment plans (Varian Truebeam LINAC, Eclipse TPS, AAA, 18MV) having both x and y jaws aligned with the farthest extent of the block outline (8mm around PTV). Then we subsequently moved either both x-jaws or all x and y jaws outwards upto 3 cm in 1 cm increments and investigated their effect on average and maximum dose to neighboring critical structures keeping the same coverage to treatment volume. Results: Lateral displacement of both x-jaws by 1cm each increased kidney and spleen mean dose by as much as 1.7% and 1.3% respectively and superior inferior displacement increased liver, right kidney, stomach and spleen dose by as much as 2.1%, 2%, 5.2% and 1.6% respectively. Displacement of all x and y-jaws away by 1cm increased the mean dose to liver, right kidney, left kidney, bowels, cord, stomach and spleen by as much as 4.9%, 5.9%, 2.1%, 2.8%, 7.4%, 10.4% and 4.2% respectively. Percentage increase in mean dose due to 2 and 3cm jaw displacement increased almost linearly with the displaced distance. Changes in maximum dose were much smaller (mostly negligible) than the changes in mean dose. Conclusion: Collimation jaw position affects dose mostly to critical structures adjacent to it. Though treatment plans with MLCs conforming the block margin usually meet dose constraints to critical structures, keeping jaws all the way in, to the edge of the block reduces dose to the critical structures during radiation treatment.

  20. Conformation of LSM/YSZ and LSM ceramic films obtained by the citrate and solid mixture techniques; Conformacao de filmes ceramicos de LSM e LSM/YSZ obtidos pelas tecnicas citratos e mistura de solidos

    Energy Technology Data Exchange (ETDEWEB)

    Chiba, R.; Vargas, R.A.; Andreoli, M.; Seo, E.S.M., E-mail: rchiba@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (CCTM/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Ciencia e Tecnologia de Materiais. Lab. de SOFC - Insumos e Componentes

    2009-07-01

    In this work, the ceramic films of LSM/YSZ (strontium-doped lanthanum manganite/Yttria-stabilized zirconia) and LSM used as cathodes of the solid oxide fuel cells (SOFC) are conformed by the wet powder spraying technique. The composite LSM/YSZ was obtained by the solid mixture technique and LSM by the citrate technique. For the formation of the LSM/YSZ and LSM ceramic films was necessary the preparation of dispersed ceramic suspensions for the deposition in YSZ substrate, used as electrolyte of the CaCOS. These powders were conformed using an aerograph for the deposition of the LSM/YSZ and LSM thin films of approximately 40 microns. The half-cells had been characterized by X-ray diffractometry (XRD), identifying the phases hexagonal (LSM) and cubica (YSZ). And electronic scanning electron microscopy (SEM) was used to evaluate the adherence and porosity of the ceramic films according to the characteristics of the cathode. (author)

  1. Dual Drug Targeting of Mutant Bcr-Abl Induces Inactive Conformation: New Strategy for the Treatment of Chronic Myeloid Leukemia and Overcoming Monotherapy Resistance.

    Science.gov (United States)

    El Rashedy, Ahmed A; Olotu, Fisayo A; Soliman, Mahmoud E S

    2018-03-01

    Bcr-Abl is an oncogenic fusion protein which expression enhances tumorigenesis, and has been highly associated with chronic myeloid leukemia (CML). Acquired drug resistance in mutant Bcr-Abl has enhanced pathogenesis with the use of single therapy agents such as nilotinib. Moreover, allosteric targeting has been identified to consequentially inhibit Bcr-Abl activity, which led to the recent development of ABL-001 (asciminib) that selectively binds the myristoyl pocket. Experimental studies have revealed that the combination of nilotinib and ABL-001 induced a 'bent' conformation in the C-terminal helix of Bcr-Abl; a benchmark of inhibition, thereby exhibiting a greater potency in the treatment of CML, surmounting the setbacks of drug resistance, disease regression and relapse. Therefore, we report the first account of the dynamics and conformational analysis of oncogenic T334I Bcr-Abl by dual targeting. Our findings revealed that unlike in the Bcr-Abl-Nilotinib complex, dual targeting by both inhibitors induced the bent conformation in the C-terminal helix that varied with time. This was coupled with significant alteration in Bcr-Abl stability, flexibility, and compactness and an overall structural re-orientation inwards towards the hydrophobic core, which reduced the solvent-exposed residues indicative of protein folding. This study will facilitate allosteric targeting and the design of more potent allosteric inhibitors for resistive target proteins in cancer. © 2018 Wiley-VHCA AG, Zurich, Switzerland.

  2. Current calibration, treatment, and treatment planning techniques among institutions participating in the Children's Oncology Group

    International Nuclear Information System (INIS)

    Urie, Marcia; FitzGerald, T.J.; Followill, David; Laurie, Fran; Marcus, Robert; Michalski, Jeff

    2003-01-01

    Purpose: To report current technology implementation, radiation therapy physics and treatment planning practices, and results of treatment planning exercises among 261 institutions belonging to the Children's Oncology Group (COG). Methods and Materials: The Radiation Therapy Committee of the newly formed COG mandated that each institution demonstrate basic physics and treatment planning abilities by satisfactorily completing a questionnaire and four treatment planning exercises designed by the Quality Assurance Review Center. The planning cases are (1) a maxillary sinus target volume (for two-dimensional planning), (2) a Hodgkin's disease mantle field (for irregular-field and off-axis dose calculations), (3) a central axis blocked case, and (4) a craniospinal irradiation case. The questionnaire and treatment plans were submitted (as of 1/30/02) by 243 institutions and completed satisfactorily by 233. Data from this questionnaire and analyses of the treatment plans with monitor unit calculations are presented. Results: Of the 243 clinics responding, 54% use multileaf collimators routinely, 94% use asymmetric jaws routinely, and 13% use dynamic wedges. Nearly all institutions calibrate their linear accelerators following American Association of Physicists in Medicine protocols, currently 16% with TG-51 and 81% with TG-21 protocol. Treatment planning systems are relied on very heavily for all calculations, including monitor units. Techniques and results of each of the treatment planning exercises are presented. Conclusions: Together, these data provide a unique compilation of current (2001) radiation therapy practices in institutions treating pediatric patients. Overall, the COG facilities have the equipment and the personnel to perform high-quality radiation therapy. With ongoing quality assurance review, radiation therapy compliance with COG protocols should be high

  3. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC. A direct comparison of PET-based treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Ruebe, Christian [Saarland University Medical School, Department of Radiotherapy and Radiation Oncology, Homburg/Saar (Germany)

    2016-02-15

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p < 0.001; IF: 74.3 vs. 70.1 Gy, p < 0.03). With IMRT-IF, a PD of at least 66 Gy was achieved for 95 % of all plans. For IF as compared with ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p < 0.00001; 3D-CRT: 20.2 vs. 9.9 %, p < 0.00001). The esophageal NTCP showed a particularly good sparing with IMRT vs. 3D-CRT (ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels. (orig.) [German] Das Potenzial der intensitaetsmodulierten Strahlentherapie (IMRT) soll im Rahmen der FDG-PET basierten Bestrahlungsplanung des lokal fortgeschrittenen nichtkleinzelligen Bronchialkarzinoms (LA-NSCLC) fuer 2 Zielvolumenansaetze (Involved-Field-Bestrahlung, IF) sowie elektive Nodalbestrahlung (ENI) geprueft und mit der 3-D-konformalen Strahlentherapie (3-D

  4. Special set-up and treatment techniques for the radiotherapy of pediatric malignancies

    International Nuclear Information System (INIS)

    Martinez, A.; Donaldson, S.S.; Bagshaw, M.A.

    1977-01-01

    The prevention of serious and long term complications of treatment have become as important a consideration in the therapy of children with malignant disease as the goal of tumor control. This balance requires meticulous treatment planning and attention to the treatment preparation and immobilization techniques when radiotherapy is administered to children. Accurate localization of tumor volume and daily reproducibility is essential for delivering precise irradiation. Four special set-up and treatment techniques which have a specific usefulness in radiotherapy for pediatric malignancies are defined and illustrated with the aid of clinical cases. They include the three point set-up, the split beam technique, the isocentric technique, and the strinking field technique

  5. 3-D conformal treatment of prostate cancer to 74 Gy vs. high-dose-rate brachytherapy boost: A cross-sectional quality-of-life survey

    Energy Technology Data Exchange (ETDEWEB)

    Vordermark, Dirk [Univ. of Wuerzburg (DE). Dept. of Radiation Oncology] (and others)

    2006-09-15

    The effects of two modalities of dose-escalated radiotherapy on health-related quality of life (HRQOL) were compared. Forty-one consecutive patients were treated with a 3-D conformal (3-DC) boost to 74 Gy, and 43 with high-dose rate (HDR) brachytherapy boost (2x9 Gy), following 3-D conformal treatment to 46 Gy. Median age was 70 years in both groups, median initial PSA was 7.9 {mu}g/l in 3-DC boost patients and 8.1 {mu}g/l in HDR boost patients. Stage was 7 in 52% and 47%, respectively. HRQOL was assessed cross-sectionally using EORTC QLQ-C30 and organ-specific PR25 modules 3-32 (median 19) and 4-25 (median 14) months after treatment, respectively. Questionnaires were completed by 93% and 97% of patients, respectively. Diarrhea and insomnia scores were significantly increased in both groups. In the PR25 module, scores of 3-DC boost and HDR boost patients for urinary, bowel and treatment-related symptoms were similar. Among responders, 34% of 3-DC boost patients and 86% of HDR boost patients had severe erectile problems. Dose escalation in prostate cancer by either 3-DC boost to 74 Gy or HDR brachytherapy boost appears to result in similar HRQOL profiles.

  6. 3-D conformal treatment of prostate cancer to 74 Gy vs. high-dose-rate brachytherapy boost: A cross-sectional quality-of-life survey

    International Nuclear Information System (INIS)

    Vordermark, Dirk

    2006-01-01

    The effects of two modalities of dose-escalated radiotherapy on health-related quality of life (HRQOL) were compared. Forty-one consecutive patients were treated with a 3-D conformal (3-DC) boost to 74 Gy, and 43 with high-dose rate (HDR) brachytherapy boost (2x9 Gy), following 3-D conformal treatment to 46 Gy. Median age was 70 years in both groups, median initial PSA was 7.9 μg/l in 3-DC boost patients and 8.1 μg/l in HDR boost patients. Stage was 7 in 52% and 47%, respectively. HRQOL was assessed cross-sectionally using EORTC QLQ-C30 and organ-specific PR25 modules 3-32 (median 19) and 4-25 (median 14) months after treatment, respectively. Questionnaires were completed by 93% and 97% of patients, respectively. Diarrhea and insomnia scores were significantly increased in both groups. In the PR25 module, scores of 3-DC boost and HDR boost patients for urinary, bowel and treatment-related symptoms were similar. Among responders, 34% of 3-DC boost patients and 86% of HDR boost patients had severe erectile problems. Dose escalation in prostate cancer by either 3-DC boost to 74 Gy or HDR brachytherapy boost appears to result in similar HRQOL profiles

  7. Treatment of nasal cavity and paranasal sinus cancer with modern radiotherapy techniques in the postoperative setting-the MSKCC experience

    International Nuclear Information System (INIS)

    Hoppe, Bradford S.; Stegman, Lauren D.; Zelefsky, Michael J.; Rosenzweig, Kenneth E.; Wolden, Suzanne L.; Patel, Snehal G.; Shah, Jatin P.; Kraus, Dennis H.; Lee, Nancy Y.

    2007-01-01

    Purpose: To perform a retrospective analysis of patients with paranasal sinus (PNS) cancer treated with postoperative radiotherapy (RT) at Memorial Sloan-Kettering Cancer Center. Methods and Materials: Between January 1987 and July 2005, 85 patients with PNS and nasal cavity cancer underwent postoperative RT. Most patients had squamous cell carcinoma (49%; n = 42), T4 tumors (52%; n = 36), and the maxillary sinus (53%; n = 45) as the primary disease site. The median radiation dose was 63 Gy. Of the 85 patients, 76 underwent CT simulation and 53 were treated with either three-dimensional conformal RT (27%; n = 23) or intensity-modulated RT (35%; n = 30). Acute and late toxicities were scored according to the Radiation Therapy Oncology Group radiation morbidity scoring criteria. Results: With a median follow-up for surviving patients of 60 months, the 5-year estimates of local progression-free, regional progression-free, distant metastasis-free, disease-free, and overall survival rates were 62%, 87%, 82%, 55%, and 67%, respectively. On multivariate analysis, squamous cell histology and cribriform plate involvement predicted for an increased likelihood of local recurrence, and squamous cell histologic features predicted for worse overall survival. None of the patients who underwent CT simulation and were treated with modern techniques developed a Grade 3-4 late complication of the eye. Conclusion: Complete surgical resection followed by adjuvant RT is an effective and safe approach in the treatment of PNS cancer. Emerging tools, such as three-dimensional conformal treatment and, in particular, intensity-modulated RT for PNS tumors, may minimize the occurrence of late complications associated with conventional RT techniques. Local recurrence remains a significant problem

  8. Three-dimensional conformal radiotherapy in the treatment of prostate cancer in Australia and New Zealand: Report on a survey of radiotherapy centres and the proceedings of a consensus workshop

    International Nuclear Information System (INIS)

    Tai, K.-H.; Duchesne, G.; See, A.; Berry, M.

    2004-01-01

    There is an increasing use of 3-D conformal radiotherapy (3DCRT) in the radiotherapeutic management of prostate cancer. The Faculty of Radiation Oncology Genito-Urinary Group carried out a survey of Australian and New Zealand radiotherapy centres in the preparation of a consensus workshop. Of the 19 centres that were represented, there were 24 radiation oncologists, 16 radiation therapists and 12 medical physicists. The survey collected demographic information and data on the practices undertaken at those centres when delivering curative radiotherapy in the treatment of prostate cancer. There was much variation in the delivery of treatment in the areas of patient set-up, contouring of target volumes and organs of interest during computer planning, the techniques and the dose constraints used in these techniques, the use of adjuvant androgen deprivation therapy and the quality assurance processes used in monitoring effects of treatment. This variability reflects the range of data in the published literature. Emerging trends of practices were also identified. This is a first report on a multi-disciplinary approach to the development of guidelines in 3DCRT of prostate cancer. Copyright (2004) Blackwell Science Pty Ltd

  9. SU-E-T-633: Preparation and Planning of a VMAT Multi - Arc Radiation Therapy Technique for Full Scalp Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, C; Bardock, A; Berkelaar, S; Gillund, D; McGee, K; Mohamed, I; Lapointe, C [British Columbia Cancer Agency, Kelowna, BC (Canada)

    2015-06-15

    Purpose: The target volume for angiosarcoma of the scalp encompasses the entire scalp. Full scalp radiotherapy (FSRT) requires careful design of required bolus, immobilization and marking of the field before the patient CT is acquired. A VMAT multi-arc technique was designed to deliver FSRT for a patient with angiosarcoma of the scalp to a dose of 6000cGy in 25 fractions. Methods: A custom bolus helmet was fabricated from a 0.5 cm thick sheet of aquaplast material, which was molded to the patient’s head. With the bolus helmet in place the patient was then positioned supine on a H&N immobilization board. A custom vaclock bag positioned on a standard headrest and a thermoplastic mask were used to immobilize the patient. Additional bolus to cover the remaining treatment area was attached to the mask. We acquired two CT scans of the patient’s head, one in treatment position and an additional scan without the immobilization mask with wires marking the treatment area that the oncologist had delineated on the patient’s skin. The second scan was registered to the first and used to define the treatment CTV. A four-arc VMAT treatment planned using Varian-Eclipse was optimized to cover the skin with a PTV margin while sparing the brain and limiting the dose to the optic apparatus and lacrimal glands. Daily treatment setup was verified using anterior and lateral kV on-board-imaging. To verify the treated dose, TLDs were positioned on the patient’s scalp during one fraction. Results: With full dose coverage to the PTV, the mean dose to the brain was less than 24 Gy. The dose measured by the TLDs (mean difference 1%, standard deviation 4%)showed excellent agreement with the treatment planning calculation. Conclusion: FSRT delivered with a bolus helmet and a VMAT multi-arc technique can be accurately delivered with high dose uniformity and conformality.

  10. SU-E-T-633: Preparation and Planning of a VMAT Multi - Arc Radiation Therapy Technique for Full Scalp Treatment

    International Nuclear Information System (INIS)

    Araujo, C; Bardock, A; Berkelaar, S; Gillund, D; McGee, K; Mohamed, I; Lapointe, C

    2015-01-01

    Purpose: The target volume for angiosarcoma of the scalp encompasses the entire scalp. Full scalp radiotherapy (FSRT) requires careful design of required bolus, immobilization and marking of the field before the patient CT is acquired. A VMAT multi-arc technique was designed to deliver FSRT for a patient with angiosarcoma of the scalp to a dose of 6000cGy in 25 fractions. Methods: A custom bolus helmet was fabricated from a 0.5 cm thick sheet of aquaplast material, which was molded to the patient’s head. With the bolus helmet in place the patient was then positioned supine on a H&N immobilization board. A custom vaclock bag positioned on a standard headrest and a thermoplastic mask were used to immobilize the patient. Additional bolus to cover the remaining treatment area was attached to the mask. We acquired two CT scans of the patient’s head, one in treatment position and an additional scan without the immobilization mask with wires marking the treatment area that the oncologist had delineated on the patient’s skin. The second scan was registered to the first and used to define the treatment CTV. A four-arc VMAT treatment planned using Varian-Eclipse was optimized to cover the skin with a PTV margin while sparing the brain and limiting the dose to the optic apparatus and lacrimal glands. Daily treatment setup was verified using anterior and lateral kV on-board-imaging. To verify the treated dose, TLDs were positioned on the patient’s scalp during one fraction. Results: With full dose coverage to the PTV, the mean dose to the brain was less than 24 Gy. The dose measured by the TLDs (mean difference 1%, standard deviation 4%)showed excellent agreement with the treatment planning calculation. Conclusion: FSRT delivered with a bolus helmet and a VMAT multi-arc technique can be accurately delivered with high dose uniformity and conformality

  11. Heart dose reduction in breast cancer treatment with simultaneous integrated boost. Comparison of treatment planning and dosimetry for a novel hybrid technique and 3D-CRT

    International Nuclear Information System (INIS)

    Joest, Vincent; Kretschmer, Matthias; Sabatino, Marcello; Wuerschmidt, Florian; Dahle, Joerg; Lorenzen, Joern; Ueberle, Friedrich

    2015-01-01

    The present study compares in silico treatment plans of clinically established three-dimensional conformal radiotherapy (3D-CRT) with a hybrid technique consisting of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) during normally fractionated radiation of mammary carcinomas with simultaneous integrated boost on the basis of dose-volume histogram (DVH) parameters. Radiation treatment planning was performed with a hybrid and a 3D-CRT treatment plan for 20 patients. Hybrid plans were implemented with two tangential IMRT fields and a VMAT field in the angular range of the tangents. Verification of the plan was performed with a manufacturer-independent measurement system consisting of a detector array and rotation unit. The mean values of the heart dose for the entire patient collective were 3.6 ± 2.5 Gy for 3D-CRT and 2.9 ± 2.1 Gy for the hybrid technique (p < 0.01). For the left side (n = 10), the mean values for the left anterior descending artery were 21.8 ± 7.4 Gy for 3D-CRT and 17.6 ± 7.4 Gy for the hybrid technique (p < 0.01). The mean values of the ipsilateral lung were 11.9 ± 1.6 Gy for 3D-CRT and 10.5 ± 1.3 Gy for the hybrid technique (p < 0.01). Calculated dose distributions in the hybrid arm were in good accordance with measured dose (on average 95.6 ± 0.5 % for γ < 1 and 3 %/3 mm). The difference of the mean treatment time per fraction was 7 s in favor of 3D-CRT. Compared with the established 3D-CRT technique, the hybrid technique allows for a decrease in dose, particularly of the mean heart and lung dose with comparable target volume acquisition and without disadvantageous low-dose load of contralateral structures. Uncomplicated implementation of the hybrid technique was demonstrated in this context. The hybrid technique combines the advantages of tangential IMRT with the superior sparing of organs at risk by VMAT. (orig.) [de

  12. Optimization of Stereotactic Radiotherapy Treatment Delivery Technique for Base-Of-Skull Meningiomas

    International Nuclear Information System (INIS)

    Clark, Brenda G.; Candish, Charles; Vollans, Emily; Gete, Ermias; Lee, Richard; Martin, Monty; Ma, Roy; McKenzie, Michael

    2008-01-01

    This study compares static conformal field (CF), intensity modulated radiotherapy (IMRT), and dynamic arcs (DA) for the stereotactic radiotherapy of base-of-skull meningiomas. Twenty-one cases of base-of-skull meningioma (median planning target volume [PTV] = 21.3 cm 3 ) previously treated with stereotactic radiotherapy were replanned with each technique. The plans were compared for Radiation Therapy Oncology Group conformity index (CI) and homogeneity index (HI), and doses to normal structures at 6 dose values from 50.4 Gy to 5.6 Gy. The mean CI was 1.75 (CF), 1.75 (DA), and 1.66 (IMRT) (p 3 , the CI (IMRT) was always superior to CI (DA) and CI (CF). At PTV sizes below 25 cm 3 , there was no significant difference in CI between each technique. There was no significant difference in HI between plans. The total volume of normal tissue receiving 50.4, 44.8, and 5.6 Gy was significantly lower when comparing IMRT to CF and DA plans (p 3 , due to improved conformity and normal tissue sparing, in particular for the brain stem and ipsilateral temporal lobe

  13. A new on-board imaging treatment technique for palliative and emergency treatments in radiation oncology

    International Nuclear Information System (INIS)

    Held, Mareike

    2016-01-01

    and reconstruction corrections. Consequently, multiple image value-to-density calibration curves are necessary for accurate dose calculation. UCSF has implemented the new technique clinically for emergency treatments on their patients who stand to benefit from the fast simulation to treatment time frame that is achieved through this on-board imaging workflow.

  14. A new on-board imaging treatment technique for palliative and emergency treatments in radiation oncology

    Energy Technology Data Exchange (ETDEWEB)

    Held, Mareike

    2016-03-23

    and reconstruction corrections. Consequently, multiple image value-to-density calibration curves are necessary for accurate dose calculation. UCSF has implemented the new technique clinically for emergency treatments on their patients who stand to benefit from the fast simulation to treatment time frame that is achieved through this on-board imaging workflow.

  15. The micro-electrolysis technique in waste water treatment

    International Nuclear Information System (INIS)

    Jiti Zhou; Weihen Yang; Fenglin Yang; Xuemin Xiang; Yulu Wang

    1997-01-01

    The micro-electrolysis is one of the efficient methods to treat some kinds of waste water. The experiments have shown its high efficiency in sewage treatment and some kinds of industrial waste water. It is suitable for pre-treatment of high concentrated waste water and deep treatment of waste water for reuse purpose. The disadvantage of micro-electrolysis is its high energy consumption in case of high electrolyte concentration. (author) 2 figs., 11 tabs., 2 refs

  16. The micro-electrolysis technique in waste water treatment

    Energy Technology Data Exchange (ETDEWEB)

    Jiti Zhou; Weihen Yang; Fenglin Yang; Xuemin Xiang; Yulu Wang [Dalian Univ. of Technology, Dalian (China)

    1997-12-31

    The micro-electrolysis is one of the efficient methods to treat some kinds of waste water. The experiments have shown its high efficiency in sewage treatment and some kinds of industrial waste water. It is suitable for pre-treatment of high concentrated waste water and deep treatment of waste water for reuse purpose. The disadvantage of micro-electrolysis is its high energy consumption in case of high electrolyte concentration. (author) 2 figs., 11 tabs., 2 refs.

  17. A Fuzzy PROMETHEE Approach for Breast Cancer Treatment Techniques

    Directory of Open Access Journals (Sweden)

    Dilber Uzun Ozsahin

    2018-05-01

    Full Text Available Breast tumor is a growth that occur in the healthy breast tissue, whereby abnormal cells undergo division in an uncontrolled manner. It comes in different types and stages and the ability to metastasize and infect distant tissues. Several studies have showed that one in eight women in the US have develop breast cancer during their life time. Therefore, early diagnosis and treatment is widely approved as being essential to effectively alleviate the disease. The aim of this study is to comparatively analyze certain breast cancer treatment procedures which include surgery, hormone therapy, chemotherapy, and radiation therapy. Fuzzy PROMETHEE (preference ranking organization method for enrichment of evaluations a multi-criteria decision-making process was used to evaluate the treatments on factors that include side effects, overall survival rate, cost of treatment and treatment time.

  18. Presentation of a 3D conformal radiotherapy technique for head-and-neck tumors resulting in substantial protection of the parotid glands

    International Nuclear Information System (INIS)

    Kuhnt, T.; Janich, M.; Gerlach, R.; Haensgen, G.; Goetz, U.; Chiricuta, I.C.

    2006-01-01

    Purpose: the aim of this study was to improve the irradiation technique for the treatment of head-and-neck tumors and, in particular, to make use of the advantages found in modern 3D planning to protect the parotid glands. Patients and methods: for this investigation the 3D dataset of a standard patient with oropharyngeal carcinoma of UICC stage IVA was used. In the CT scans (slice thickness 5 mm) the planning target volume (PTV), the boost volume and both parotids were delineated. Three different techniques were calculated for two different dose levels (50 Gy for PTV and 64 Gy for boost volume, using single doses of 2 Gy). For technique 1 (T1) a parallel opposed field photon/electron irradiation was designed, for technique 2 (T2) an opposed/arc field irradiation was employed, and for technique 3 (T3) a combination of a static coplanar and arc field irradiation was designed. The sum doses D min , D max and D mean for PTV, boost volume, and ipsilateral and contralateral parotid gland were evaluated, and the time needed for calculation of the plans was also determined. Results: for all techniques used, the calculated doses in the PTV (D min 5.6 ± 0.1 Gy, D max 73.7 ± 0.1 Gy, and D mean 57.9 ± 0.5 Gy) and in the boost volume (D min 46.9 ± 1.5 Gy, D max 73.8 ± 0.12 Gy, and D mean 65.8 ± 0.9 Gy) were equal. Significant differences were found regarding the three different techniques, e.g., for the ipsilateral parotid gland D min (T1 = 47.4, T2 = 50.6, and T3 = 38.4 Gy) as well as for the contralateral parotid gland D min (T1 = 42.1, T2 = 44.2, and T3 = 17.8 Gy) and D mean (T1 = 51.3, T2 = 52.8, and T3 = 32.6 Gy). Regarding the three different techniques, significant differences were found in favor of T3. The determined planning times were as follows: T1 = 90, T2 = 60, and T3 = 90 min. Conclusion: the combination of static coplanar and arc field technique (T3) resulted in a substantially better protection as compared to both other techniques. This was especially the

  19. The evolution of rectal and urinary toxicity and immune response in prostate cancer patients treated with two three-dimensional conformal radiotherapy techniques

    Czech Academy of Sciences Publication Activity Database

    Vránová, J.; Vinakurau, S.; Richter, J.; Starec, M.; Fišerová, Anna; Rosina, J.

    2011-01-01

    Roč. 2, č. 6 (2011), s. 1-13 ISSN 1748-717X R&D Projects: GA AV ČR IAA500200620 Institutional research plan: CEZ:AV0Z50200510 Keywords : 3-dimensional conformal radiotherapy (3DCRT) * gastrointestinal and genitourinary toxicity * prostate cancer Subject RIV: EC - Immunology Impact factor: 2.321, year: 2011

  20. Treatment of Some Hazardous Industrial Pollutants by Simple Oxidation Techniques

    International Nuclear Information System (INIS)

    Abd El-Rahman, N.M.

    1999-01-01

    Central treatment of Industrial wastewater requires pretreatment of some specific pollutants which may be not effectively degraded in down stream processes in central treatment unit. Some of the hazardous pollutants in industrial wastewater including acrylonitrile, pesticides and some commonly used dyes (active and acid dyes) have been subjected individually to oxidation using hydrogen peroxide catalyzed by ferrous ions in acidic solution. Treatment efficiency was monitored by chemical oxygen demand (COD) removal using a specially developed concentration/COD curves. Initial concentrations (in terms of COD) were 910 PPM, 1348 and 530 ppm and the respective COD reductions were 91, 98 and 99%, for the pesticide, acrylonitrile and the reactive dye. Oxidative degradation of polared and acid green also reduced COD by 99 and 100% respectively. The obtained results confirm the appropriateness of oxidative degradation as a pretreatment for some hazardous pollutants prior to treatment in central facilities or municipal activated sludge stations

  1. Couching Techniques for Cataract Treatment in Osogbo, South West ...

    African Journals Online (AJOL)

    Objectives: To find out the different techniques of couching, highlight the unacceptable poor visual sequelae and assess knowledge, attitudes, and practices of subjects. Settings and Design: Clinic based and prospective observational study. Methods and Material: Structured interview and clinical examination of consecutive ...

  2. 3D Conformal radiotherapy for gastric cancer-results of a comparative planning study

    International Nuclear Information System (INIS)

    Leong, Trevor; Willis, David; Joon, Daryl Lim; Condron, Sara; Hui, Andrew; Ngan, Samuel Y.K.

    2005-01-01

    Background and purpose: Many radiation oncologists are reluctant to use anteroposterior-posteroanterior (AP-PA) field arrangements when treating gastric cancer with adjuvant postoperative radiotherapy due to concerns about normal tissue toxicity, particularly in relation to the kidneys and spinal cord. In this report, we describe a multiple-field conformal radiotherapy technique, and compare this technique to the more commonly used AP-PA technique that was used in the recently reported Intergroup study (INT0116). Materials and methods: Fifteen patients with stages II-IV adenocarcinoma of the stomach were treated with adjuvant postoperative chemoradiotherapy using a standardised 3D conformal radiotherapy technique that consisted of a 'split-field', mono-isocentric arrangement employing 6 radiation fields. For each patient, a second radiotherapy treatment plan was generated utilising AP-PA fields. The two techniques were then compared for target volume coverage and dose to normal tissues using dose volume histogram (DVH) analysis. Results: The conformal technique provides more adequate coverage of the target volume with 99% of the planning target volume (PTV) receiving 95% of the prescribed dose, compared to 93% using AP-PA fields. Comparative DVHs for the right kidney, left kidney and spinal cord demonstrate lower radiation doses using the conformal technique, and although the liver dose is higher, it is still well below liver tolerance. Conclusions: 3D conformal radiotherapy produces superior dose distributions and reduced radiation doses to the kidneys and spinal cord compared to AP-PA techniques, with the potential to reduce treatment toxicity

  3. Research and development of treatment techniques for LLW from decommissioning: Decontamination and volume reduction techniques

    International Nuclear Information System (INIS)

    Hirabayashi, T.; Kameo, Y.; Nakashio, N.

    2001-01-01

    For the purpose of reducing the amount and/or volume of low-level radioactive waste (LLW) arising from decommissioning of nuclear reactor, the Japan Atomic Energy Research Institute (JAERI) has been developing four decontamination techniques. They are: (a) Gas-carrying abrasive method, (b) In-situ remote electropolishing method for pipe system before dismantling, (c) Bead reaction - thermal shock method, and (d) Laser induced chemical method for components after dismantling. JAERI in developing techniques are also carrying out melting tests of metal and non-metal. Melting was confirmed to be effective in reducing the volume, homogenizing, and furthermore stabilizing non-metallic wastes. (author)

  4. Effective music therapy techniques in the treatment of nonfluent aphasia.

    Science.gov (United States)

    Tomaino, Concetta M

    2012-04-01

    In music therapy for nonfluent aphasia patients who have difficulty producing meaningful words, phrases, and sentences, various benefits of singing have been identified: strengthened breathing and vocal ability, improved articulation and prosody of speech, and increased verbal and nonverbal communicative behaviors. This paper will introduce these various techniques used in clinical music therapy, and summarize findings based on our recent study to illustrate the strength of different techniques emphasizing rhythm, pitch, memory, and vocal/oral motor components dealing with different symptoms. The efficacy of each component is enhanced or diminished by the choice of music and the way it is interactively delivered. This indicates that neural mechanisms underlying speech improvement vary greatly with available acoustic and social cues in aphasic brain. © 2012 New York Academy of Sciences.

  5. Clinically Enhancing Local Anesthesia Techniques for Endodontic Treatment.

    Science.gov (United States)

    Bahcall, James; Xie, Qian

    2017-02-01

    Local anesthesia is one of the most important drugs given to patients who undergo endodontic treatment. Yet, clinicians often do not view local anesthetic agents as drugs and, therefore, struggle clinically to consistently achieve profound pulpal anesthesia. To improve the clinical effects of local anesthesia for endodontic treatment, in conjunction with selecting the correct type of local anesthesia, clinicians need to thoroughly understand how the local anesthetic process works and how to objectively test for clinical signs of pulpal anesthesia and integrate supplemental anesthesia when appropriate.

  6. Comparison of two different debonding techniques in orthodontic treatment.

    Science.gov (United States)

    Piccoli, Luca; Migliau, Guido; Besharat, Laith Konstantinos; Di Carlo, Stefano; Pompa, Giorgio; Di Giorgio, Roberto

    2017-01-01

    The purpose of this research is to investigate whether and how the adhesive bond failure site varied in relation to the material used for the orthodontic bonding and debonding technique applied. Two different methods of orthodontic debonding were included in our survey; cutters for orthodontics and debonding plier. Three different materials for the adhesion of the bracket: composite light curing, self-curing composite and glass ionomer cement. The remaining amount of adhesive on the tooth surface is an important parameter that gives information on how the location of the posting site varied during the debonding. 60 dental elements, maxillary and mandibular, previously extracted for orthodontic reasons, as well as periodontal, were included in our research. We investigated a possible significant correlation between different variables (debonding technique and materials for membership) and the ARI index. The use of orthodontic cutters or debonding pliers does not affect the adhesive bond failure site and both techniques have a tendency to leave a significant amount of adhesive on the surface enamel. In the resin-reinforced glass ionomer cements, detachment occurs at the interface enamel-adhesive and this pattern of detachment increases the risk of the enamel damage during debonding. In both types of composite resins (photopolymerizable or self-curing), the detachment occurs at the interface bracketing adhesive. In this case the amount of remaining adhesive material on the tooth must be removed with further methods, which in addition, increase the risk of iatrogenic injury as well as the working hours.

  7. The Modified Kimura's Technique for the Treatment of Duodenal Atresia

    Directory of Open Access Journals (Sweden)

    Biagio Zuccarello

    2009-01-01

    Full Text Available Background/Purpose. Kimura's diamond-shaped-duodenoduodenostomy (DSD is a known technique for the correction of congenital intrinsic duodenal obstruction. We present a modification of the technique and review the advantages of this new technique. Methods. From 1992 to 2006, 14 newborns were treated for duodenal atresia. We inverted the direction of the duodenal incisions: a longitudinal incision was made in the proximal duodenum while the distal was opened by transverse incision. Results. Our “inverted-diamond-shaped-duodenoduodenostomy” (i-DSD allowed postoperative oral feeding to start on days 2 to 3, peripheral intravenous fluids discontinuity on days 3 to 8 (median values 3.6; time to achieve full oral feeds on days 8 to 12 (median values 9.4; the length of hospitalisation ranged from 10 and 14 days (median value 11.2. No complications related to the anastomosis, by Viz leakage, dehiscence, biliary stasis, or stenosis were observed. Conclusions. The i-DSD provides a safe procedure to protect the ampulla of Vater from injury and avoids any formation of a blind loop. The results show that patients who have i-DSD achieve full oral feeds in a very short time period and, consequently, the length of hospitalisation is also significantly reduced.

  8. Electromyographic evaluation in children orthodontically treated for skeletal Class II malocclusion: Comparison of two treatment techniques.

    Science.gov (United States)

    Ortu, Eleonora; Pietropaoli, Davide; Adib, Fray; Masci, Chiara; Giannoni, Mario; Monaco, Annalisa

    2017-11-16

    Objective To compare the clinical efficacy of two techniques for fabricating a Bimler device by assessing the patient's surface electromyography (sEMG) activity at rest before treatment and six months after treatment. Methods Twenty-four patients undergoing orthodontic treatment were enrolled in the study; 12 formed the test group and wore a Bimler device fabricated with a Myoprint impression using neuromuscular orthodontic technique and 12 formed the control group and were treated by traditional orthodontic technique with a wax bite in protrusion. The "rest" sEMG of each patient was recorded prior to treatment and six months after treatment. Results The neuromuscular-designed Bimler device was more comfortable and provided better treatment results than the traditional Bimler device. Conclusion This study suggests that the patient group subjected to neuromuscular orthodontic treatment had a treatment outcome with more relaxed masticatory muscles and better function versus the traditional orthodontic treatment.

  9. Dosimetric comparison of IMRT and modulated arc-therapy techniques in the treatment of cervical cancers; Comparaison dosimetrique des techniques de RCMI et d'arctherapie modulee dans le traitement des cancers du col uterin

    Energy Technology Data Exchange (ETDEWEB)

    Renard-Oldrini, S.; Charra-Brunaud, C.; Tournier-Rangeard, L.; Huger, S.; Marchesi, V.; Bouziz, D.; Peiffert, D. [Centre Alexis-Vautrin, Nancy (France)

    2011-10-15

    The authors report the dosimetric comparison of two techniques used for the treatment of cervical cancers: the intensity-modulated conformational radiotherapy (IMRT) with static beams and modulated arc-therapy with RapidArc. The treatment plans of 15 patients have been compared. The clinical target volume (CTV) comprises the gross target volume, the cervix, the upper third of the vagina, and ganglionary areas. The previsional target volume comprises the clinical target volume and a one centimetre margin. Organs at risk are rectum, bladder, intestine and bone marrow. Arc-therapy seems to provide a better sparing of intestine that IMRT, while maintaining a good coverage of the previsional target volume and decreasing treatment duration. Short communication

  10. Volumetric intensity-modulated arc therapy vs. 3-dimensional conformal radiotherapy for primary chemoradiotherapy of anal carcinoma. Effects on treatment-related side effects and survival

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Hanne Elisabeth; Droege, Leif Hendrik; Hennies, Steffen; Herrmann, Markus Karl; Wolff, Hendrik Andreas [University Medical Center Goettingen, Dept. of Radiotherapy and Radiooncology, Goettingen (Germany); Gaedcke, Jochen [University Medical Center Goettingen, Dept. of General Surgery, Goettingen (Germany)

    2015-11-15

    Primary chemoradiotherapy (CRT) is the standard treatment for locally advanced anal carcinoma. This study compared volumetric intensity-modulated arc therapy (VMAT) to 3-dimensional conformal radiotherapy (3DCRT) in terms of treatment-related side effects and survival. From 1992-2014, 103 consecutive patients with anal carcinoma UICC stage I-III were treated. Concomitant CRT consisted of whole pelvic irradiation, including the iliac and inguinal lymph nodes, with 50.4 Gy (1.8 Gy per fractions) by VMAT (n = 17) or 3DCRT (n = 86) as well as two cycles of 5-fluorouracil and mitomycin C. Acute organ and hematological toxicity were assessed according to the Common Terminology Criteria (CTC) for Adverse Events version 3.0. Side effects ≥ grade 3 were scored as high-grade toxicity. High-grade acute organ toxicity CTC ≥ 3 (P < 0.05), especially proctitis (P = 0.03), was significantly reduced in VMAT patients. The 2-year locoregional control (LRC) and disease-free survival (DFS) were both 100 % for VMAT patients compared with 80 and 73 % for 3DCRT patients. VMAT was shown to be a feasible technique, achieving significantly lower rates of acute organ toxicity and promising results for LRC and DFS. Future investigations will aim at assessing the advantages of VMAT with respect to late toxicity and survival after a prolonged follow-up time. (orig.) [German] Die primaere Radiochemotherapie (RCT) gilt als Standardtherapie fuer lokal fortgeschrittene Analkarzinome. In dieser Studie wurde die volumetrisch modulierte Rotationstherapie (''volumetric intensity-modulated arc therapy'', VMAT) mit der klassischen dreidimensionalen konformalen Radiotherapie (3DCRT) hinsichtlich therapieassoziierter Nebenwirkungen und Ueberleben verglichen. Von 1992-2014 wurden 103 aufeinanderfolgende Patienten mit einem Analkarzinom im UICC-Stadium I-III behandelt. Die kombinierte RCT bestand aus der Bestrahlung des gesamten Beckens inklusive der iliakalen und der inguinalen

  11. Computer-controlled 3-D treatment delivery

    International Nuclear Information System (INIS)

    Fraass, Benedick A.

    1995-01-01

    Purpose/Objective: This course will describe the use of computer-controlled treatment delivery techniques for treatment of patients with sophisticated conformal therapy. In particular, research and implementation issues related to clinical use of computer-controlled conformal radiation therapy (CCRT) techniques will be discussed. The possible/potential advantages of CCRT techniques will be highlighted using results from clinical 3-D planning studies. Materials and Methods: In recent years, 3-D treatment planning has been used to develop and implement 3-D conformal therapy treatment techniques, and studies based on these conformal treatments have begun to show the promise of conformal therapy. This work has been followed by the development of commercially-available multileaf collimator and computer control systems for treatment machines. Using these (and other) CCRT devices, various centers are beginning to clinically use complex computer-controlled treatments. Both research and clinical CCRT treatment techniques will be discussed in this presentation. General concepts and requirements for CCRT will be mentioned. Developmental and clinical experience with CCRT techniques from a number of centers will be utilized. Results: Treatment planning, treatment preparation and treatment delivery must be approached in an integrated fashion in order to clinically implement CCRT treatment techniques, and the entire process will be discussed. Various CCRT treatment methodologies will be reviewed from operational, dosimetric, and technical points of view. The discussion will concentrate on CCRT techniques which are likely to see rather wide dissemination over the next several years, including particularly the use of multileaf collimators (MLC), dynamic and segmental conformal therapy, conformal field shaping, and other related techniques. More advanced CCRT techniques, such as the use of individualized intensity modulation of beams or segments, and the use of computer

  12. Reconstruction techniques in the treatment of vertebral neoplasms.

    Science.gov (United States)

    Biagini, R; Boriani, S; Casadei, R; Bandiera, S; De Iure, F; Campanacci, L; Demitri, S; Orsini, U; Di Fiore, M

    1997-01-01

    The authors present a new system for the topographical description of vertebral neoplasms. The general criteria of reconstruction after curettage or vertebral resection are evaluated. The literature is reviewed in terms of the use of prostheses, bone grafts, cement and stabilization systems in the treatment of tumors of the spine. Indications for the different methods are discussed.

  13. Molecular Genetics Techniques to Develop New Treatments for Brain Cancers

    Energy Technology Data Exchange (ETDEWEB)

    Fox, Jacob; Fathallan-Shaykh, Hassan

    2006-09-22

    The objectives of this report are: (1) to devise novel molecular gene therapies for malignant brain tumors, (2) advance our understanding of the immune system in the central nervous system; and (3) apply genomics to find molecular probes to diagnose brain tumors, predict prognosis, biological behavior and their response to treatment.

  14. Some techniques used in the treatment of phenolic waters residual

    International Nuclear Information System (INIS)

    Alzate S, Rafael A.; Botero, Carlos Andre

    2000-01-01

    The current state of the diverse processes of treatment of phenolic waters residual is presented, beginning with the methods traditionally employees, until finishing with those but recent innovations, which have been derived of the necessity of increasing the removal of these pollutants without increasing the costs of such processes in excessive form

  15. Comparison of Techniques for Preimplantation Treatment of Osteochondral Allograft Bone.

    Science.gov (United States)

    Baumann, Charles A; Baumann, John R; Bozynski, Chantelle C; Stoker, Aaron M; Stannard, James P; Cook, James L

    2018-03-07

    Articular defects are a major problem with few effective treatment options. Osteochondral allograft (OCA) transplantation can be an effective treatment; however, lack of OCA bone integration can cause failure. This controlled laboratory study was designed to compare clinically applicable methods for marrow element removal and enhanced delivery of bone marrow aspirate concentrate (BMC) to OCA bone. We hypothesized that compressed carbon dioxide (CO 2 ) treatment of OCA bone would result in significantly better marrow element removal, significantly more retention and distribution of viable osteoprogenitor cells, and significantly higher osteoinductive protein elution from OCAs compared with other preimplantation treatments. Fresh humeral heads ( n  = 24) were harvested and stored for 14 days, then randomly assigned to treatment based on marrow element removal and bone treatment: (standard of care [SOC]) ( n  = 4) - SOC high-pulse saline lavage, no BMC; (BMC) ( n  = 5) - saline lavage then canine BMC; (Drill + BMC) ( n  = 5) - 1.1 mm drill-hole immediately subchondral then saline lavage then BMC injection through drill hole; (Carb + BMC) ( n  = 5) - saline lavage then CO 2 then BMC; or (Saline-Carb + BMC) ( n  = 5) - saline lavage and CO 2 together then BMC. Treated OCAs were cultured for 14 days. On day 3, media were collected, centrifuged to isolate cells, and replaced. Cells were cultured for 11 days for colony forming unit (CFU) determination. OCA media were collected on days 7 and 14 of culture for analysis. On day 14, each graft was assessed for viable cell retention and distribution, and bone marrow element removal. BMC had significantly higher ( p  = 0.001) viable cell distribution compared with the SOC, Drill + BMC, Carb + BMC, and Saline-Carb + BMC groups. BMC and Drill + BMC had significantly higher ( p  BMC, and Saline-Carb + BMC. Drill + BMC and Carb + BMC had the highest media

  16. Conformal Tachyons

    CERN Document Server

    Tomaschitz, R

    2000-01-01

    We study tachyons conformally coupled to the background geometry of a Milne universe. The causality of superluminal signal transfer is scrutinized in this context. The cosmic time of the comoving frame determines a distinguished time order for events connected by superluminal signals. An observer can relate his rest frame to the galaxy frame, and compare so the time order of events in his proper time to the cosmic time order. All observers can in this way arrive at identical conclusions on the causality of events connected by superluminal signals. An unambiguous energy concept for tachyonic rays is defined by means of the cosmic time of the comoving reference frame, without resorting to an antiparticle interpretation. On that basis we give an explicit proof that no signals can be sent into the past of observers. Causality violating signals are energetically forbidden, as they would have negative energy in the rest frame of the emitting observer. If an observer emits a superluminal signal, the tachyonic respon...

  17. Accelerated hypofractionated three-dimensional conformal radiation therapy in the treatment of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Yu Jinming; Zheng Aiqing; Yu Yonghua; Wang Xuetao; Yuan Shuanghu; Han Dali; Li Kunhai

    2005-01-01

    Objective: To evaluate the effect and complication of non-small-cell lung cancer (NSCLC) treated with accelerated hypofractionated three dimensional conforms] radiation therapy (3DCRT). Methods: There were squamous carcinoma 21, adenocarcinoma 7, squamous-adenocarcinoma 4 and other cancer 3. There were 17 stage I and 18 stage II. Thirty-five patients of NSCLC were treated with a dose of 30-48 Gy in 6 or 8 Gy per fraction, 3 times a week. The outcome of these patients Was analyzed. Results: The overall 1-, 2- and 3- Year survival rate was 78.2%, 46.9% and 36.3%, respectively. The 1- and 2-year recurrence-free survival rate was 64.6 % and 39.7 %, respectively. The acute radiation pneumonitis and late lung fibrosis rates were high. Univariate analysis showed that Vm was a significant predictor of acute radiation pneumonitis. Conclusion: Compared with accelerated hypofractionated irradiation, the routine conventional fractionated radiation therapy may be preferred for more patients of NSCLC. (authors)

  18. Ultrasound-guided high dose rate conformal brachytherapy boost in prostate cancer: treatment description and preliminary results of a phase I/II clinical trial

    Energy Technology Data Exchange (ETDEWEB)

    Stromberg, Jannifer; Martinez, Alvaro; Gonzalez, Jose; Edmundson, Gregory; Ohanian, Neshan; Vicini, Frank; Hollander, Jay; Gustafson, Gary; Spencer, William; Di, Yan; Brabbins, Donald

    1995-08-30

    Purpose: To improve results for locally advanced prostate cancer, a prospective clinical trial of concurrent external beam irradiation and fractionated iridium-192 (Ir-192) high dose rate (HDR) conformal boost brachytherapy was initiated. Methods and Materials: Between November 1991 and February 1994, 99 implants were performed on 33 patients with prostatic adenocarcinoma at William Beaumont Hospital. Using AJCC staging criteria, 9 patients had T2b tumors, 17 patients had T2c tumors, and 7 patients had T3 disease. Patients were treated with (a) 45.6 Gy whole pelvis external irradiation and (b) three HDR fractions of 5.5 Gy each (18 patients) or 6 Gy each (15 patients) to the prostate. Transperineal needle implants using real-time ultrasound guidance with interactive on-line isodose distributions were performed on an outpatient basis during weeks 1, 2, and 3 of external irradiation. Acute toxicity was scored using the Radiation Therapy Oncology Group (RTOG) morbidity grading system. Results: This technique of concurrent external pelvic irradiation and conformal HDR brachytherapy was well tolerated. No significant intraoperative or perioperative complications occurred. Three patients (9%) experienced Grade 3 acute toxicity (two dysuria and one diarrhea). All toxicities were otherwise Grades 1 or 2 and were primarily as expected from pelvic external irradiation. Persistent implant-related toxicities included Grades 1-2 perineal pain (12%) and hematospermia (15%). Median follow-up time was 13 months. Serum prostatic-specific antigen (PSA) levels normalized in 91% of patients (29 out of 32) within 1-14 months (median 2.8 months) after irradiation. PSA levels were progressively decreasing in the other three patients at last measurement. Prospectively planned prostatic rebiopsies done at 18 months in the first 10 patients were negative in 9 out of 10 (90%). Conclusions: Acute toxicity has been acceptable with this unique approach using conformal high dose rate Ir-192

  19. 40 CFR 141.111 - Treatment techniques for acrylamide and epichlorohydrin.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Treatment Techniques § 141.111 Treatment techniques for acrylamide and epichlorohydrin. Each public water system must certify... and epichlorohydrin are used in drinking water systems, the combination (or product) of dose and...

  20. Laminoplasty Techniques for the Treatment of Multilevel Cervical Stenosis

    Directory of Open Access Journals (Sweden)

    Lance K. Mitsunaga

    2012-01-01

    Full Text Available Laminoplasty is one surgical option for cervical spondylotic myelopathy. It was developed to avoid the significant risk of complications associated with alternative surgical options such as anterior decompression and fusion and laminectomy with or without posterior fusion. Various laminoplasty techniques have been described. All of these variations are designed to reposition the laminae and expand the spinal canal while retaining the dorsal elements to protect the dura from scar formation and to preserve postoperative cervical stability and alignment. With the right surgical indications, reliable results can be expected with laminoplasty in treating patients with multilevel cervical myelopathy.

  1. Improvement of the technique in treatment of internal hemorrhoids with Nd:YAG laser

    Science.gov (United States)

    Bao, Xiao-qing; Zhu, Jing; Shi, Hong-Min

    2005-07-01

    Objective: To observe and study the improvement of the technique in treatment of internal hemorrhoids with Nd:YAG laser and evaluate the effective rate. Methods: 60 patients of internal hemorrhoids were treated with Nd:YAG laser (10-15mw) irradiating on the mucosa of the lesions. Results: Among 60 patients, 57 patients were primarily cured with one treatment, 3 patients were primarily cured with two treatments. The effective rate was 95% with one treatment, and it reached to 100% with two treatments. Conclusions: the improvement of the technique in treatment of internal hemorrhoids with Nd:YAG laser is effective and easy to operate.

  2. New Image-Based Techniques for Prostate Biopsy and Treatment

    Science.gov (United States)

    2012-04-01

    correspondence between the pathology slices and the MR image slices. The processing and paraffin embedding were carried out in a routine manner, except using...results (Mor- ris et al., 2009). In this treatment, 40-150 small radioactive seeds (Iodine-125 or Palladium-103) are inserted through the perineum and...creating the VE images. Any out of plane motion, including the lat- eral motions caused by the slippage between the protective sheath on the probe and the

  3. Winery wastewater treatment using the land filter technique.

    Science.gov (United States)

    Christen, E W; Quayle, W C; Marcoux, M A; Arienzo, M; Jayawardane, N S

    2010-08-01

    This study outlines a new approach to the treatment of winery wastewater by application to a land FILTER (Filtration and Irrigated cropping for Land Treatment and Effluent Reuse) system. The land FILTER system was tested at a medium size rural winery crushing approximately 20,000 tonnes of grapes. The approach consisted of a preliminary treatment through a coarse screening and settling in treatment ponds, followed by application to the land FILTER planted to pasture. The land FILTER system efficiently dealt with variable volumes and nutrient loads in the wastewater. It was operated to minimize pollutant loads in the treated water (subsurface drainage) and provide adequate leaching to manage salt in the soil profile. The land FILTER system was effective in neutralizing the pH of the wastewater and removing nutrient pollutants to meet EPA discharge limits. However, suspended solids (SS) and biological oxygen demand (BOD) levels in the subsurface drainage waters slightly exceeded EPA limits for discharge. The high organic content in the wastewater initially caused some soil blockage and impeded drainage in the land FILTER site. This was addressed by reducing the hydraulic loading rate to allow increased soil drying between wastewater irrigations. The analysis of soil characteristics after the application of wastewater found that there was some potassium accumulation in the profile but sodium and nutrients decreased after wastewater application. Thus, the wastewater application and provision of subsurface drainage ensured adequate leaching, and so was adequate to avoid the risk of soil salinisation. Crown Copyright 2010. Published by Elsevier Ltd. All rights reserved.

  4. Treatment of celiac artery stenosis with interventional techniques

    International Nuclear Information System (INIS)

    Wang Maoqiang; Wang Zhijun; Liu Fengyong; Wang Zhongpu

    2005-01-01

    Objective: To present two cases of celiac artery (CA) stenosis treated successfully by interventional technique. Methods: Two patients characterised by chronic upper abdominal pain after eating, associated with weight loss and an epigastric bruit were treated with interventional procedure. The diagnosis was suggested by color Doppler imaging of the celiac axis and confirmed by aortography. One patient possessed the classic triad of median arcuate ligament syndrome (MALS). Arteriosclerosis was found to be responsible for the CA stenosis in another one. The interventional technique consisted of conventional PTA and stent placement in the CA. Results: Abdominal arteriograms in both patients showed severe stenosis (>90%) of CA. The stenotic segments were dilated and stented during the same session. One patient with balloon expandable Palmaz stent placed in the proximal celiac artery, another with 2 wallstents deployed in the CA trunk. The post procedural arteriograms showed good dilation of the lesions with immediate improvement of CA blood flow. Follow-up Doppler ultrasound scans showed normal flow patterns in the CA. Three months after the procedures, their upper gastrointestinal symptoms had resolved and regained body weights. They remained well and free of symptoms, at 16 months and 26 months follow-up, respectively, after the procedure. Conclusions: CA stenosis can successfully be treated with angioplasty and stenting. (authors)

  5. Endobutton technique for the treatment of acute acromioclavicular joint dislocations

    Directory of Open Access Journals (Sweden)

    Raif Özden

    2014-06-01

    Full Text Available Objective: Acromioclavicular (AC joint dislocation is a common injury frequently affecting young athletes. The aim of this study is to evaluate postoperative functional results in cases diagnosed with acute AC joint dislocation stabilized with endobutton system. Methods: This fixation procedure has been applied on 10 patients. Indications of the technique included: a grade V AC joint dislocation (7 patients, and grade III AC joint dislocation (3 patient according to Rockwood classification. The coracoclavicular (CC interval and AC joint were reduced using two endobuttons. One endobutton was fitted on the clavicle and the second was placed at the undersurface of the coracoid. Outcomes were assessed with the Constant shoulder score and visual analog pain scale. Results: All the patients had powerful intraoperative fixation. Immediately after surgery, and 6 weeks, and 1 year postoperative radiographs showed adequate reduction of the CC distance and the AC joint. The mean Constant shoulder score was 89 (88–92 in the injured shoulder and 90 (88–93 in the uninjured shoulder. There was no statically significant difference between the injured and normal shoulder in terms of Constant shoulder score and there was no complication during the process. Conclusion: This technique is a safe and effective method for providing fixation for the AC joint.

  6. [Guideline-conform psychiatric psychotherapeutic treatment for patients with schizophrenia : A normative evaluation of necessary personnel requirements].

    Science.gov (United States)

    Mehl, S; Falkai, P; Berger, M; Löhr, M; Rujescu, D; Wolff, J; Kircher, T

    2016-03-01

    Although national treatment guidelines and current publications of the German Federal Joint Committee (Gemeinsamer Bundesausschuss) recommend cognitive behavior therapy for all patients with schizophrenia, the implementation of these recommendations in current inpatient and outpatient treatment is only rudimentary. The aim of this study was to systematically search randomized controlled studies (RCTs), meta-analyses and the guidelines of the German Association for Psychiatry and Psychotherapy, Psychosomatics and Neurology (DGPPN) and the British National Institute for Health and Clinical Excellence (NICE) in order to assess the number of personnel necessary for psychiatric and therapeutic inpatient treatment in line with present guidelines. Moreover, the number of staff required was compared with the personnel resources designated by the German psychiatry personnel regulations (Psych-PV). The German and NICE guidelines, RCTs and meta-analyses were analyzed and an adequate weekly treatment plan for an inpatient unit was developed. Moreover, the number of personnel necessary to realize the treatment plan was calculated. In order to realize adequate inpatient treatment approximately 107 min extra for medical psychotherapeutic personnel per patient and week (of which 72 min for psychotherapy) and another 60 min for nursing staff per patient and week are required in addition to the current Psych-PV regulations. Thus, implementation in an open ward with 20 inpatients would require 3.62 positions for physicians, 0.7 positions in psychology and 12.85 positions for nursing staff (including management positions and night shifts). These evidence-based recommendations for precise specifications of inpatient treatment should lead to improved inpatient treatment in line with present guidelines. Moreover, outpatients and day patients could be included in this treatment model. The results should be considered in the construction of the future prospective payment system for

  7. Conformal field theory in conformal space

    International Nuclear Information System (INIS)

    Preitschopf, C.R.; Vasiliev, M.A.

    1999-01-01

    We present a new framework for a Lagrangian description of conformal field theories in various dimensions based on a local version of d + 2-dimensional conformal space. The results include a true gauge theory of conformal gravity in d = (1, 3) and any standard matter coupled to it. An important feature is the automatic derivation of the conformal gravity constraints, which are necessary for the analysis of the matter systems

  8. Novel Electromagnetic - Ultrasound Synergistic Technique for Treatment of Cancer

    Science.gov (United States)

    2013-11-01

    6 APPENDICES……….…………………………………………………….…. 8 Partnering PI Final Progress Report: DOD Award BC095397P1 Initiating PI: Mahta Moghaddam...and Volume Integral Formulation Mark Haynes, Member, IEEE, sacha a. M. Verweij, Mahta Moghaddam, Fellow, IEEE, and Paul l. carson, Senior Member... Mahta Moghaddam, Fellow, IEEE Abstract—A preclinical prototype of a transcutaneous thermal therapy system has been developed for the targeted treatment

  9. SU-F-SPS-04: Dosimetric Evaluation of the Dose Calculation Accuracy of Different Algorithms for Two Different Treatment Techniques During Whole Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Pacaci, P; Cebe, M; Mabhouti, H; Codel, G; Serin, E; Sanli, E; Kucukmorkoc, E; Doyuran, M; Kucuk, N; Canoglu, D; Altinok, A; Acar, H; Caglar Ozkok, H [Medipol University, Istanbul, Istanbul (Turkey)

    2016-06-15

    Purpose: In this study, dosimetric comparison of field in field (FIF) and intensity modulated radiation therapy (IMRT) techniques used for treatment of whole breast radiotherapy (WBRT) were made. The dosimetric accuracy of treatment planning system (TPS) for Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) algorithms in predicting PTV and OAR doses was also investigated. Methods: Two different treatment planning techniques of left-sided breast cancer were generated for rando phantom. FIF and IMRT plans were compared for doses in PTV and OAR volumes including ipsilateral lung, heart, left ascending coronary artery, contralateral lung and the contralateral breast. PTV and OARs doses and homogeneity and conformality indexes were compared between two techniques. The accuracy of TPS dose calculation algorithms was tested by comparing PTV and OAR doses measured by thermoluminescent dosimetry with the dose calculated by the TPS using AAA and AXB for both techniques. Results: IMRT plans had better conformality and homogeneity indexes than FIF technique and it spared OARs better than FIF. While both algorithms overestimated PTV doses they underestimated all OAR doses. For IMRT plan, PTV doses, overestimation up to 2.5 % was seen with AAA algorithm but it decreased to 1.8 % when AXB algorithm was used. Based on the results of the anthropomorphic measurements for OAR doses, underestimation greater than 7 % is possible by the AAA. The results from the AXB are much better than the AAA algorithm. However, underestimations of 4.8 % were found in some of the points even for AXB. For FIF plan, similar trend was seen for PTV and OARs doses in both algorithm. Conclusion: When using the Eclipse TPS for breast cancer, AXB the should be used instead of the AAA algorithm, bearing in mind that the AXB may still underestimate all OAR doses.

  10. A new three-dimensional conformal radiotherapy (3DCRT) technique for large breast and/or high body mass index patients: evaluation of a novel fields assessment aimed to reduce extra–target-tissue irradiation

    Science.gov (United States)

    Stimato, Gerardina; Ippolito, Edy; Silipigni, Sonia; Venanzio, Cristina Di; Gaudino, Diego; Fiore, Michele; Trodella, Lucio; D'Angelillo, Rolando Maria; Ramella, Sara

    2016-01-01

    Objective: To develop an alternative three-dimensional treatment plan with standardized fields class solution for whole-breast radiotherapy in patients with large/pendulous breast and/or high body mass index (BMI). Methods: Two treatment plans [tangential fields and standardized five-fields technique (S5F)] for a total dose of 50 Gy/25 fractions were generated for patients with large breasts [planning target volume (PTV) >1000 cm3 and/or BMI >25 kg m−2], supine positioned. S5F plans consist of two wedged tangential beams, anteroposterior: 20° for the right breast and 340° for the left breast, and posteroanterior: 181° for the right breast and 179° for the left breast. A field in field in medial–lateral beam and additional fields were added to reduce hot spot areas and extra–target-tissue irradiation and to improve dose distribution. The percentage of PTV receiving 95% of the prescribed dose (PTV V95%), percentage of PTV receiving 105% of the prescribed dose (PTV V105%), maximal dose to PTV (PTV Dmax), homogeneity index (HI) and conformity index were recorded. V10%, V20%, V105% and V107% of a “proper” normal tissue structure (body-PTV healthy tissue) were recorded. Statistical analyses were performed using SYSTAT v.12.0 (SPSS, Chicago, IL). Results: In 38 patients included, S5F improved HI (8.4 vs 10.1; p ≤ 0.001) and significantly reduced PTV Dmax and PTV V105%. The extra–target-tissue irradiation was significantly reduced using S5F for V105% (cm3) and V107% (cm3) with a very high difference in tissue irradiation (46.6 vs 3.0 cm3, p ≤ 0.001 for V105% and 12.2 vs 0.0 cm3, p ≤ 0.001 for V107% for tangential field and S5F plans, respectively). Only a slight increase in low-dose extra–target-tissue irradiation (V10%) was observed (2.2719 vs 1.8261 cm3, p = 0.002). Conclusion: The S5F technique in patients with large breast or high BMI increases HI and decreases hot spots in extra-target-tissues and can therefore be

  11. Role of Imaging Techniques in Percutaneous Treatment of Mitral Regurgitation.

    Science.gov (United States)

    Li, Chi-Hion; Arzamendi, Dabit; Carreras, Francesc

    2016-04-01

    Mitral regurgitation is the most prevalent valvular heart disease in the United States and the second most prevalent in Europe. Patients with severe mitral regurgitation have a poor prognosis with medical therapy once they become symptomatic or develop signs of significant cardiac dysfunction. However, as many as half of these patients are inoperable because of advanced age, ventricular dysfunction, or other comorbidities. Studies have shown that surgery increases survival in patients with organic mitral regurgitation due to valve prolapse but has no clinical benefit in those with functional mitral regurgitation. In this scenario, percutaneous repair for mitral regurgitation in native valves provides alternative management of valvular heart disease in patients at high surgical risk. Percutaneous repair for mitral regurgitation is a growing field that relies heavily on imaging techniques to diagnose functional anatomy and guide repair procedures. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  12. Physical quantities, their role and treatment in gasflow measurement techniques

    International Nuclear Information System (INIS)

    Narjes, L.

    1977-06-01

    We begin by taking a closer look at the concepts physical quantity, dimension and unit of measurement. Then a survey is given of the physical quantities applied in gasflow measurement techniques. Here the volume-, as well as the mass-flow rate, as derived quantities are of particular interest. The application of these quantities in relation to the legal units of measurement is specifically described. In addition the quantity equation and further the quantity equation adapted to the use of suitable units and their modes of application are compared. In the appendix four examples clarify these modes. Special attention is paid to the quantity equation adapted to practically oriented units. The applications of this type of equation in VDI regulations, standards and other technical guidelines for measurement of flow are mentioned. Moreover, the meaning of the standard state for the comparison of flows of gaseous fluids is illustrated. The difficulties concerning an international agreement on uniform standard temperature are explained. Starting from there, the advantages of the fundamental quantity 'amount of substance' applied to the measurement of flow are described. The use of this quantity for the thermodynamic state of ideal and real gases, respectively gas mixtures, is demonstrated in the appendix by an example. (orig.) [de

  13. Implementation of intensity-modulated conformational radiotherapy for cervical cancers at the Alexis Vautrin Centre

    International Nuclear Information System (INIS)

    Renard-Oldrini, Sophie

    2010-01-01

    As platinum salt based concomitant conformational radiotherapy and chemotherapy have been used as a standard treatment for cervical cancers but resulted in digestive and haematological toxicities, this research thesis reports the application of intensity-modulated conformational radiation therapy. After having recalled some epidemiological, anatomical aspects, diagnosis and treatments aspects regarding cervical cancer, the author presents this last treatment technique (principles, benefits, practical implementation). The author discusses results obtained by an experiment during which seven patients have been treated by simple conformational radiation therapy, and four by intensity-modulated conformational radiation therapy. Results are discussed in terms of volumes (clinical target volume, growth target volume, planned target volume), dosimetric results, toxicities (urine and skin), weight loss [fr

  14. Translating regenerative medicine techniques for the treatment of epilepsy

    Directory of Open Access Journals (Sweden)

    Takao Yasuhara

    2017-01-01

    Full Text Available Epilepsy is considered a chronic neurological disorder and is accompanied by persistent and diverse disturbances in electrical brain activity. While antiepileptic pharmaceuticals are still the predominant treatment for epilepsy, the advent of numerous surgical interventions has further improved outcomes for patients. Despite these advancements, a subpopulation continues to experience intractable seizures which are resistant to current conventional and nonconventional therapeutic options. In this review, we begin with an introduction to the clinical presentation of epilepsy before discussing the clinically relevant laboratory models of epilepsy. Finally, we explore the implications of regenerative medicine – including cell therapy, neuroprotective agents, and electrical stimulation – for epilepsy, supplemented with our laboratory's data. This paper is a review article. Referred literature in this paper has been listed in the references section. The datasets supporting the conclusions of this article are available online by searching various databases, including PubMed. Some original points in this article come from the laboratory practice in our research center and the authors' experiences.

  15. The value of 18F-FDG PET in three-dimensional conformal radiotherapy of cancer

    International Nuclear Information System (INIS)

    Lv Huiqing; Zhang Zhongmin; Lv Zhonghong

    2006-01-01

    Three-dimensional conformal radiotherapy (3D-CRT) is based on an extensive use of modern medical imaging techniques. Delineation of the gross tumor volume and organs at risk constitutes one of the most important phases of conformal radiotherapy procedures. 18 F-fluorodeoxyglucose ( 18 F-FDG) PET possesses greater sensitivity and accuracy in detecting diseased lymph nodes, is an important staging examination for patients considered for radiation treatment with curative intent. 18 F-FDG PET has an important role in delineation of gross tumor volume for patients treated with three-dimensional conformal radiotherapy. (authors)

  16. 4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion?

    Science.gov (United States)

    Tseng, Yolanda D.; Wootton, Landon; Nyflot, Matthew; Apisarnthanarax, Smith; Rengan, Ramesh; Bloch, Charles; Sandison, George; St. James, Sara

    2018-01-01

    Four dimensional computed tomography (4DCT) scans are routinely used in radiation therapy to determine the internal treatment volume for targets that are moving (e.g. lung tumors). The use of these studies has allowed clinicians to create target volumes based upon the motion of the tumor during the imaging study. The purpose of this work is to determine if a target volume based on a single 4DCT scan at simulation is sufficient to capture thoracic motion. Phantom studies were performed to determine expected differences between volumes contoured on 4DCT scans and those on the evaluation CT scans (slow scans). Evaluation CT scans acquired during treatment of 11 patients were compared to the 4DCT scans used for treatment planning. The images were assessed to determine if the target remained within the target volume determined during the first 4DCT scan. A total of 55 slow scans were compared to the 11 planning 4DCT scans. Small differences were observed in phantom between the 4DCT volumes and the slow scan volumes, with a maximum of 2.9%, that can be attributed to minor differences in contouring and the ability of the 4DCT scan to adequately capture motion at the apex and base of the motion trajectory. Larger differences were observed in the patients studied, up to a maximum volume difference of 33.4%. These results demonstrate that a single 4DCT scan is not adequate to capture all thoracic motion throughout treatment.

  17. Dosimetric comparison of helical tomotherapy, intensity-modulated radiation therapy, volumetric-modulated arc therapy, and 3-dimensional conformal therapy for the treatment of T1N0 glottic cancer

    International Nuclear Information System (INIS)

    Ekici, Kemal; Pepele, Eda K.; Yaprak, Bahaddin; Temelli, Oztun; Eraslan, Aysun F.; Kucuk, Nadir; Altınok, Ayse Y.; Sut, Pelin A.; Alpak, Ozlem D.; Colak, Cemil; Mayadagli, Alpaslan

    2016-01-01

    Various radiotherapy planning methods for T1N0 laryngeal cancer have been proposed to decrease normal tissue toxicity. We compare helical tomotherapy (HT), linac-based intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and 3-D conformal radiotherapy (3D-CRT) techniques for T1N0 laryngeal cancer. Overall, 10 patients with T1N0 laryngeal cancer were selected and evaluated. Furthermore, 10 radiotherapy treatment plans have been created for all 10 patients, including HT, IMRT, VMAT, and 3D-CRT. IMRT, VMAT, and HT plans vs 3D-CRT plans consistently provided superior planning target volume (PTV) coverage. Similar target coverage was observed between the 3 IMRT modalities. Compared with 3D-CRT, IMRT, HT, and VMAT significantly reduced the mean dose to the carotid arteries. VMAT resulted in the lowest mean dose to the submandibular and thyroid glands. Compared with 3D-CRT, IMRT, HT, and VMAT significantly increased the maximum dose to the spinal cord It was observed that the 3 IMRT modalities studied showed superior target coverage with less variation between each plan in comparison with 3D-CRT. The 3D-CRT plans performed better at the D max of the spinal cord. Clinical investigation is warranted to determine if these treatment approaches would translate into a reduction in radiation therapy–induced toxicities.

  18. [Techniques and complementary techniques. Complementary treatments: nitric oxide, prone positioning and surfactant].

    Science.gov (United States)

    Martos Sánchez, I; Vázquez Martínez, J L; Otheo de Tejada, E; Ros, P

    2003-11-01

    The management of hypoxic respiratory failure is based on oxygen delivery and ventilatory support with lung-protective ventilation strategies. Better understanding of acute lung injury have led to new therapeutic approaches that can modify the outcome of these patients. These adjunctive oxygenation strategies include inhaled nitric oxide and surfactant delivery, and the use of prone positioning. Nitric oxide is a selective pulmonary vasodilator that when inhaled, improves oxygenation in clinical situations such as persistent pulmonary hypertension of the newborn, pulmonary hypertension associated with congenital heart disease, and acute respiratory distress syndrome (ARDS). When applied early in ARDS, prone positioning improves distribution of ventilation and reduces the intrapulmonary shunt. The surfactant has dramatically decreased mortality caused by hyaline membrane disease in premature newborns, although the results have been less successful in ARDS. Greater experience is required to determine whether the combination of these treatments will improve the prognosis of these patients.

  19. Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

    International Nuclear Information System (INIS)

    Scalchi, Paolo; Righetto, Roberto; Cavedon, Carlo; Francescon, Paolo; Colombo, Federico

    2010-01-01

    Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of

  20. SYSTEMATIC SCANNING ELECTRON MICROSCOPY TECHNIQUE FOR EVALUATING COMBINED BIOLOIGCAL/GRANULAR ACTIVATED CARBON TREATMENT PROCESSES

    Science.gov (United States)

    A systematic scanning election microscope analytical technique has been developed to examine granular activated carbon used a a medium for biomass attachment in liquid waste treatment. The procedure allows for the objective monitoring, comparing, and trouble shooting of combined ...

  1. Intensity modulated radiation therapy for squamous cell carcinoma of the vulva: Treatment technique and outcomes

    Directory of Open Access Journals (Sweden)

    Yuan James Rao, MD

    2017-04-01

    Conclusions: IMRT for vulvar cancer is associated with high rates of LRC in the postoperative setting and limited radiation-related toxicity. Durable LRC of disease after definitive IMRT remains challenging, and several refinements to our treatment technique are suggested.

  2. Establishing stereotactic body radiotherapy with flattening filter free techniques in the treatment of pulmonary lesions - initial experiences from a single institution

    International Nuclear Information System (INIS)

    Rieber, Juliane; Tonndorf-Martini, Eric; Schramm, Oliver; Rhein, Bernhard; König, Laila; Adeberg, Sebastian; Meyerhof, Eva; Mohr, Angela; Kappes, Jutta; Hoffmann, Hans; Debus, Jürgen; Rieken, Stefan

    2016-01-01

    Stereotactic body radiotherapy (SBRT) using flattening filter free (FFF)-techniques has been increasingly applied during the last years. However, clinical studies investigating this emerging technique are still rare. Hence, we analyzed toxicity and clinical outcome of pulmonary SBRT with FFF-techniques and performed dosimetric comparison to conventional techniques using flattening filters (FF). Between 05/2014 and 06/2015, 56 consecutive patients with 61 pulmonary lesions were treated with SBRT in FFF-mode. Central lesions received 8 × 7.5 Gy delivered to the conformally enclosing 80 %-isodose, while peripheral lesions were treated with 3 × 15 Gy, prescribed to the 65 %-isodose. Early and late toxicity (after 6 months) as well as initial clinical outcomes were evaluated. Furthermore, [deleted] plan quality and efficiency were evaluated by analyzing conformity, beam- on and total treatment delivery times in comparison to plans with FF-dose application. Median follow-up time was 9.3 months (range 1.5–18.0 months). Early toxicity was low with only 5 patients (8.9 %) reporting CTCAE 2° or higher side-effects. Only one patient (1.8 %) was diagnosed with radiation-induced pneumonitis CTCAE 3°, while 2 (3.6 %) patients suffered from pneumonitis CTCAE 2°. After 6 months, no toxicity greater than CTCAE 2° was reported. 1-year local progression-free survival, distant progression-free survival and overall survival were 92.8 %, 78.0 %, and 94.4 %, respectively. While plan quality was similar for FFF- and FF-plans in respect to conformity (p = 0.275), median beam-on time as well as total treatment time were significantly reduced for SBRT in FFF-mode compared to FF-mode (p ≤ 0.001, p ≤ 0.001). Patient treatment with SBRT using FFF-techniques is safe and provides promising clinical results with only modest toxicity at significantly increased dose delivery speed

  3. Guideline-conformity of initiation with oral hypoglycemic treatment for patients with newly therapy-dependent type 2 diabetes mellitus in Austria.

    Science.gov (United States)

    Winkelmayer, Wolfgang C; Stedman, Margaret R; Pogantsch, Michaela; Wieninger, Peter; Bucsics, Anna; Asslaber, Markus; Bauer, Rosemarie; Burkhardt, Thomas; Schautzer, Alexandra; Brookhart, M Alan

    2011-01-01

    To determine guideline conformity of initiation of oral hypoglycemic (OH) treatment for type 2 diabetes in Austria; to study patient and prescriber correlates of recommended initiation with metformin monotherapy. We used claims from 11 sickness funds that covered 7.5 million individuals, representing >90% of the Austrian population. First-time OH use was defined as a first filled prescription after one year without any OH drug or insulin. Among these incident users, we described the OH drug class used and defined correlates of initiation with metformin monotherapy. From 1/2007 to 6/2008, we identified 42,882 incident users of an OH drug: 70.8% used metformin, 24.7% used a sulfonylurea, and 4.5% initiated treatment with another class. We estimated the incidence of OH-dependent type 2 diabetes at 3.8-4.4 per 1000 patient-years. We conducted multivariate analyses among 39 077 patients with available prescriber information. Independent correlates of initiation with metformin were younger age, female gender, waived co-payment, more recent initiation, fewer hospital days and more therapeutic classes received in the year prior to first OH therapy (all p metformin initiation. Approximately 20% of metformin initiators had a second OH drug added within metformin (renal insufficiency, hepatic failure), metformin as recommended by international guidelines. At least 20% did not, taking into account possible contraindications, which provides an opportunity for intervention. Copyright © 2010 John Wiley & Sons, Ltd.

  4. Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT with 3-dimensional conformal radiation therapy (3DCRT in the hypofractionated treatment of high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Yartsev Slav

    2008-01-01

    Full Text Available Abstract Background To compare two strategies of dynamic intensity modulated radiation therapy (dIMRT with 3-dimensional conformal radiation therapy (3DCRT in the setting of hypofractionated high-risk prostate cancer treatment. Methods 3DCRT and dIMRT/Helical Tomotherapy(HT planning with 10 CT datasets was undertaken to deliver 68 Gy in 25 fractions (prostate and simultaneously delivering 45 Gy in 25 fractions (pelvic lymph node targets in a single phase. The paradigms of pelvic vessel targeting (iliac vessels with margin are used to target pelvic nodes and conformal normal tissue avoidance (treated soft tissues of the pelvis while limiting dose to identified pelvic critical structures were assessed compared to 3DCRT controls. Both dIMRT/HT and 3DCRT solutions were compared to each other using repeated measures ANOVA and post-hoc paired t-tests. Results When compared to conformal pelvic vessel targeting, conformal normal tissue avoidance delivered more homogenous PTV delivery (2/2 t-test comparisons; p dose, 1–3 Gy over 5/10 dose points; p Conclusion dIMRT/HT nodal and pelvic targeting is superior to 3DCRT in dose delivery and critical structure sparing in the setting of hypofractionation for high-risk prostate cancer. The pelvic targeting paradigm is a potential solution to deliver highly conformal pelvic radiation treatment in the setting of nodal location uncertainty in prostate cancer and other pelvic malignancies.

  5. Emerging paradigm in radiobiology in concept and practices of hypo fractionated conformal radiotherapy

    International Nuclear Information System (INIS)

    Mishra, S.P.; Srivastava, Anoop Kumar; Rastogi, Madhup; Khurana, Rohini; Pawaskar, Asawari

    2016-01-01

    This study has been performed in clinical setting by creating the treatment plan in dynamic conformal arc mode as the treatment delivery technique; with add on collimator APEX system having 56 pairs of 2.5 mm each as treatment unit. Photon beam energy selected for the study was 6 MV. Various number of treatment arcs were applied depending upon the location of the PTV. The PTV was prescribed a total dose of 60 Gy in five fractions

  6. Techniques of treatment or conditioning for waste arising from 131I production

    International Nuclear Information System (INIS)

    Dellamono, J.C.

    1989-07-01

    Distillation, evaporation/crystallization, direct immobilization and some chemical like precipitation and reduction were studied as techniques of treatment or conditioning for waste arising from 131 I production. The description of all techniques studied, as well as evaluation and discussion of the results are presented. (author) [pt

  7. Review of deep inspiration breath-hold techniques for the treatment of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Latty, Drew, E-mail: drew.latty@health.nsw.gov.au [Crown Princess Mary Cancer Centre, Westmead Hospital, Sydney, New South Wales (Australia); Stuart, Kirsty E [Crown Princess Mary Cancer Centre, Westmead Hospital, Sydney, New South Wales (Australia); Westmead Breast Cancer Institute, Sydney, New South Wales (Australia); Wang, Wei [Crown Princess Mary Cancer Centre, Westmead Hospital, Sydney, New South Wales (Australia); Westmead Breast Cancer Institute, Sydney, New South Wales (Australia); Nepean Cancer Care Centre, Sydney, New South Wales (Australia); Ahern, Verity [Crown Princess Mary Cancer Centre, Westmead Hospital, Sydney, New South Wales (Australia)

    2015-03-15

    Radiation treatment to the left breast is associated with increased cardiac morbidity and mortality. The deep inspiration breath-hold technique (DIBH) can decrease radiation dose delivered to the heart and this may facilitate the treatment of the internal mammary chain nodes. The aim of this review is to critically analyse the literature available in relation to breath-hold methods, implementation, utilisation, patient compliance, planning methods and treatment verification of the DIBH technique. Despite variation in the literature regarding the DIBH delivery method, patient coaching, visual feedback mechanisms and treatment verification, all methods of DIBH delivery reduce radiation dose to the heart. Further research is required to determine optimum protocols for patient training and treatment verification to ensure the technique is delivered successfully.

  8. Checking behavioral conformance of artifacts

    NARCIS (Netherlands)

    Fahland, D.; Leoni, de M.; Dongen, van B.F.; Aalst, van der W.M.P.

    2011-01-01

    The usefulness of process models (e.g., for analysis, improvement, or execution) strongly depends on their ability to describe reality. Conformance checking is a technique to validate how good a given process model describes recorded executions of the actual process. Recently, artifacts have been

  9. SU-E-T-538: Lung SBRT Dosimetric Comparison of 3D Conformal and RapidArc Planning

    International Nuclear Information System (INIS)

    Jiang, R; Zhan, L; Osei, E

    2015-01-01

    Purpose: Dose distributions of RapidArc Plan can be quite different from standard 3D conformal radiation therapy. SBRT plans can be optimized with high conformity or mimic the 3D conformal treatment planning with very high dose in the center of the tumor. This study quantifies the dosimetric differences among 3D conformal plan; flattened beam and FFF beam RapidArc Plans for lung SBRT. Methods: Five lung cancer patients treated with 3D non-coplanar SBRT were randomly selected. All the patients were CT scanned with 4DCT to determine the internal target volume. Abdominal compression was applied to minimize respiratory motion for SBRT patients. The prescription dose was 48 Gy in 4 fractions. The PTV coverage was optimized by two groups of objective function: one with high conformity, another mimicking 3D conformal dose distribution with high dose in the center of PTV. Optimization constraints were set to meet the criteria of the RTOG-0915 protocol. All VMAT plans were optimized with the RapidArc technique using four full arcs in Eclipse treatment planning system. The RapidArc SBRT plans with flattened 6MV beam and 6MV FFF beam were generated and dosimetric results were compared with the previous treated 3D non-coplanar plans. Results: All the RapidArc plans with flattened beam and FFF beam had similar results for the PTV and OARs. For the high conformity optimization group, The DVH of PTV exhibited a steep dose fall-off outside the PTV compared to the 3D non-coplanar plan. However, for the group mimicking the 3D conformal target dose distribution, although the PTV is very similar to the 3D conformal plan, the ITV coverage is better than 3D conformal plan. Conclusion: Due to excellent clinical experiences of 3D conformal SBRT treatment, the Rapid Arc optimization mimicking 3D conformal planning may be suggested for clinical use

  10. Applied Technologies and Prospects of Conformance Control Treatments in China Technologies et perspectives pour l’amélioration du profil de balayage dans les champs pétroliers matures produits par injection d’eau en Chine

    Directory of Open Access Journals (Sweden)

    Liu Yuzhang

    2010-02-01

    Full Text Available China is the largest user of chemical-based conformance control treatments and a series of technologies have been successfully developed and deployed in recent years. This paper first shows the milestones of development and application of conformance control technologies in China. Then integrated conformance control technologies are reviewed followed by the lessons we have learned, and then a few major specific conformance control technologies are addressed, including tracer injection and channels explanation, potentiometric testing to identify areal sweep efficiency, Pressure Index (PI decisionmaking technology to select well candidate, complementary decision-making technology to select well candidate and design application parameters, and major chemicals for in-depth fluid diversion technologies. In addition, this paper also describes the principles and applications of some promising technologies of combined chemical-based conformance treatment with other EOR/IOR process, including the combination technology of surfactant and water shutoff, profile control and mini-scale surfactant flooding, acid treatment and profile control treatment. Finally, this paper summarizes the problems and challenges faced by mature water flooded oilfields in China. Based on recent well tests, tracer testing and interpretation, and previous water control treatment experience, it appears that channels or high permeability streaks are common in mature water flooded oilfields. Some research directions and promising technologies are suggested. La Chine est le plus grand utilisateur de méthodes chimiques pour l’amélioration du profil de balayage de l’eau pour l’exploitation des champs pétroliers matures. Toute une série de technologies y ont d’ailleurs été créées et déployées avec succès ces dernières années. Cet article commence par présenter les étapes du développement et de la mise en place de ces technologies de contrôle de profil en Chine

  11. Treatment of prostatic cancer using daily intermittent multiportal therapy (DIMT) technique

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Keishiro; Irie, Goro (Hokkaido Univ., Sapporo (Japan). School of Medicine); Shirato, Hiroki; Takayama, Naohisa; Sutoh, Susumu

    1992-06-01

    In the treatment of prostatic cancer using a newly proposed intermittent multiportal therapy (DIMT), acute reactions, change in tumor marker levels, and complications more than 6 months after treatment were evaluated. From June 1989 to September 1990, 26 patients with prostatic cancer (stage A2, 3 patients; B, 9; C, 2; D, 10; recurrence, 2) were treated. Fifteen patients were followed up for more than one year, with a mean period of 11.6 months. The treatment schedule is 52.5 Gy in 16 fractions in 4 weeks for radical treatment, and 30.0 Gy in 8 fractions in 2 weeks for palliative treatment. The 360 degree rotation about the patient was divided into 16 fractions, and 2 opposing fractions were used in one day as parallel opposed portals to treat the target volume. The fractions were serially treated one per day, so that 8 treatment days produced a total dose of distribution similar to that for conventional conformational therapy. The size of the irradiation field varied from 6 x 6 cm to 9 x 9 cm. No hormonal therapy was performed for stage A2 or B. Acute effect was minimal including skin erythema 2/26 (7%), pollakisuria 1/26 (4%), mild symptoms due to acute proctitis 9/26 (35%). Abnormality high PSA and/or PAP levels returned to the normal range after the treatment in 7 of 10 patients. Local recurrence was detected in 1 patient with stage D, 15 months after completion of therapy, but 21 other patients continued for more than 6 months with no clinical evidence of local recurrence. No residual disease was detected by biopsy undertaken in 10 patients after more than 6 months. No severe complication was detected after more than 6 months except in 1 patient who needed colostomy for the relief of rectal bleeding. DIMT can have the total dose distribution similar to that of conventional conformational therapy without specific devices. Initial results on prostatic cancer treatment were encouraging. (J.P.N.).

  12. New Techniques for Optimal Treatment Planning for LINAC-based Sterotactic Radiosurgery

    International Nuclear Information System (INIS)

    Suh, Tae Suk

    1992-01-01

    Since LINAC-based stereotactic radiosurgery uses multiple noncoplanar arcs, three-dimensional dose evaluation and many beam parameters, a lengthy computation time is required to optimize even the simplest case by a trial and error. The basic approach presented in this paper is to show promising methods using an experimental optimization and an analytic optimization. The purpose of this paper is not to describe the detailed methods, but introduce briefly, proceeding research done currently or in near future. A more detailed description will be shown in ongoing published papers. Experimental optimization is based on two approaches. One is shaping the target volumes through the use of multiple isocenters determined from dose experience and testing. The other method is conformal therapy using a beam eye view technique and field shaping. The analytic approach is to adapt computer-aided design optimization in finding optimum irradiation parameters automatically

  13. Waste treatment in NUCEF facility with silver mediated electrochemical oxidation technique

    International Nuclear Information System (INIS)

    Umeda, M.; Sugikawa, S.

    2000-01-01

    Silver mediated electrochemical oxidation technique has been considered one of promising candidates for alpha-bearing waste treatment. Destruction tests of organic compounds, such as insoluble tannin, TBP and dodecane, were carried out by this technique and the experimental data such as destruction rates, current efficiencies and intermediates were obtained. These compounds could be completely mineralized without the formation of reactive organic nitrate associated to safety hazards. On the basis of these results, the applicability of silver mediated electrochemical oxidation technique to waste treatment in NUCEF was evaluated. (authors)

  14. Radiosurgery with flattening-filter-free techniques in the treatment of brain metastases. Plan comparison and early clinical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Rieber, J.; Tonndorf-Martini, E.; Schramm, O.; Rhein, B.; Stefanowicz, S.; Lindel, K.; Debus, J.; Rieken, S. [University Hospital Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Heidelberg Institute of Radiation Oncology, Heidelberg (Germany); Kappes, J. [Heidelberg University, Translational Research Unit, Thoraxklinik, Heidelberg (Germany); Heidelberg University, Department of Pneumology, Thoraxklinik, Heidelberg (Germany); Member of the German Centre for Lung Research (DZL), Translational Lung Research Centre Heidelberg (TLRC-H), Heidelberg (Germany); Hoffmann, H. [Heidelberg University, Translational Research Unit, Thoraxklinik, Heidelberg (Germany); Heidelberg University, Department of Thoracic Surgery, Thoraxklinik, Heidelberg (Germany); Member of the German Centre for Lung Research (DZL), Translational Lung Research Centre Heidelberg (TLRC-H), Heidelberg (Germany)

    2016-11-15

    Radiosurgical treatment of brain metastases is well established in daily clinical routine. Utilization of flattening-filter-free beams (FFF) may allow for more rapid delivery of treatment doses and improve clinical comfort. Hence, we compared plan quality and efficiency of radiosurgery in FFF mode to FF techniques. Between November 2014 and June 2015, 21 consecutive patients with 25 brain metastases were treated with stereotactic radiosurgery (SRS) in FFF mode. Brain metastases received dose-fractionation schedules of 1 x 20 Gy or 1 x 18 Gy, delivered to the conformally enclosing 80 % isodose. Three patients with critically localized or large (>3 cm) brain metastases were treated with 6 x 5 Gy. Plan quality and efficiency were evaluated by analyzing conformity, dose gradients, dose to healthy brain tissue, treatment delivery time, and number of monitor units. FFF plans were compared to those using the FF method, and early clinical outcome and toxicity were assessed. FFF mode resulted in significant reductions in beam-on time (p < 0.001) and mean brain dose (p = 0.001) relative to FF-mode comparison plans. Furthermore, significant improvements in dose gradients and sharper dose falloffs were found for SRS in FFF mode (-1.1 %, -29.6 %; p ≤ 0.003), but conformity was slightly superior in SRS in FF mode (-1.3 %; p = 0.001). With a median follow-up time of 5.1 months, 6-month overall survival was 63.3 %. Local control was observed in 24 of 25 brain metastases (96 %). SRS in FFF mode is time efficient and provides similar plan quality with the opportunity of slightly reduced dose exposure to healthy brain tissue when compared to SRS in FF mode. Clinical outcomes appear promising and show only modest treatment-related toxicity. (orig.) [German] Die radiochirurgische Behandlung (SRS) von Hirnmetastasen wird vielfach in der klinischen Routine durchgefuehrt. Die zusaetzliche Anwendung von ausgleichsfilterfreien Bestrahlungstechniken (FFF) kann die Bestrahlungszeit

  15. Evaluation of the treatment planning system of three-dimensional conformal external radiotherapy in Hospital Mexico of San Jose, Costa Rica

    International Nuclear Information System (INIS)

    Venegas Rojas, Deybith

    2014-01-01

    An evaluation and analysis are realized of dosimetry of the treatment planning system (TPS) of three-dimensional conformal external radiotherapy in the Servicio de Radioterapia of the Hospital Mexico of Costa Rica. An evaluation procedure is proposed based on IAEA-TECDOC-1540 document, and may continue to be applied periodically in this or other radiotherapy services. Tests realized have checked the representation of distances and electronics densities transferred to the TPS, match with those of real objects. The 16 tests applied have represented situations of real treatments with different configurations and beam modifiers in the equipment used daily. The tests have measured the absorbed dose to water in different significant points at different depths, using photon beams of 6 MeV and 18 MeV. The physical parameters of the tests were simulated. The absorbed dose has been calculated at specified points. The XiO and Eclipse TPS have been used with the calculation algorithms: Superposition, Convolution and AAA. The results of the calculations are evaluated with statistical methods and comparing them with the measurements of absorbed dose. A generalized tendency has been detected toward negative relative errors, implying an underestimation of the dose by the TPS; due to a difference found in the accelerator output factor respect to its commissioning. The AAA algorithm has determined a better performance, although with greater difficulties of calculus in the region of build-up. Convolution and Superposition algorithms have had similar performances and both have presented problems in high depths and out of edges of the fields. The result of the dosimetric evaluation has been satisfactory in real conditions of equipment; but several particularities have been found that should be reviewed and adjusted. The precision of the TPS has been adequate in the majority of situations important for treatment planning. [author] [es

  16. Conformal maps between pseudo-Finsler spaces

    Science.gov (United States)

    Voicu, Nicoleta

    The paper aims to initiate a systematic study of conformal mappings between Finsler spacetimes and, more generally, between pseudo-Finsler spaces. This is done by extending several results in pseudo-Riemannian geometry which are necessary for field-theoretical applications and by proposing a technique that reduces some problems involving pseudo-Finslerian conformal vector fields to their pseudo-Riemannian counterparts. Also, we point out, by constructing classes of examples, that conformal groups of flat (locally Minkowskian) pseudo-Finsler spaces can be much richer than both flat Finslerian and pseudo-Euclidean conformal groups.

  17. Topics in conformal field theory

    International Nuclear Information System (INIS)

    Kiritsis, E.B.

    1988-01-01

    In this work two major topics in Conformal Field Theory are discussed. First a detailed investigation of N = 2 Superconformal theories is presented. The structure of the representations of the N = 2 superconformal algebras is investigated and the character formulae are calculated. The general structure of N = 2 superconformal theories is elucidated and the operator algebra of the minimal models is derived. The first minimal system is discussed in more detail. Second, applications of the conformal techniques are studied in the Ashkin-Teller model. The c = 1 as well as the c = 1/2 critical lines are discussed in detail

  18. SU-F-T-188: A Robust Treatment Planning Technique for Proton Pencil Beam Scanning Cranial Spinal Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, M; Mehta, M; Badiyan, S; Young, K; Malyapa, R; Regine, W; Langen, K [University of Maryland School of Medicine, Baltimore, MD (United States); Yam, M [University of Florida Proton Therapy Institute, Jacksonville, FL (United States)

    2016-06-15

    Purpose: To propose a proton pencil beam scanning (PBS) cranial spinal irradiation (CSI) treatment planning technique robust against patient roll, isocenter offset and proton range uncertainty. Method: Proton PBS plans were created (Eclipse V11) for three previously treated CSI patients to 36 Gy (1.8 Gy/fractions). The target volume was separated into three regions: brain, upper spine and lower spine. One posterior-anterior (PA) beam was used for each spine region, and two posterior-oblique beams (15° apart from PA direction, denoted as 2PO-15) for the brain region. For comparison, another plan using one PA beam for the brain target (denoted as 1PA) was created. Using the same optimization objectives, 98% CTV was optimized to receive the prescription dose. To evaluate plan robustness against patient roll, the gantry angle was increased by 3° and dose was recalculated without changing the proton spot weights. On the re-calculated plan, doses were then calculated using 12 scenarios that are combinations of isocenter shift (±3mm in X, Y, and Z directions) and proton range variation (±3.5%). The worst-case-scenario (WCS) brain CTV dosimetric metrics were compared to the nominal plan. Results: For both beam arrangements, the brain field(s) and upper-spine field overlap in the T2–T5 region depending on patient anatomy. The maximum monitor unit per spot were 48.7%, 47.2%, and 40.0% higher for 1PA plans than 2PO-15 plans for the three patients. The 2PO-15 plans have better dose conformity. At the same level of CTV coverage, the 2PO-15 plans have lower maximum dose and higher minimum dose to the CTV. The 2PO-15 plans also showed lower WCS maximum dose to CTV, while the WCS minimum dose to CTV were comparable between the two techniques. Conclusion: Our method of using two posterior-oblique beams for brain target provides improved dose conformity and homogeneity, and plan robustness including patient roll.

  19. Application of minimally invasive technique in surgical treatment of pancreatic diseases

    Directory of Open Access Journals (Sweden)

    ZHANG Yixi

    2015-05-01

    Full Text Available In recent years, with the rapid development of minimally invasive concept, from laparoscopic operation to three-dimension laparoscopic technique and to robotic surgical system, treatment modalities have changed a lot. Pancreatic diseases, including multiple lesions, have different prognoses. An appropriate surgical procedure should be selected while ensuring the radical treatment of disease, so as to minimize the injury to patients and the impairment of organ function. Minimally invasive technique is of great significance in the surgical treatment of pancreatic diseases.

  20. Respiration-induced movement of the upper abdominal organs: a pitfall for the three-dimensional conformal radiation treatment of pancreatic cancer

    International Nuclear Information System (INIS)

    Bussels, Barbara; Goethals, Laurence; Feron, Michel; Bielen, Didier; Dymarkowski, Steven; Suetens, Paul; Haustermans, Karin

    2003-01-01

    Respiration-induced movement of the upper abdominal organs (pancreas, liver and kidneys) was assessed in 12 subjects using dynamic magnetic resonance imaging. The movement of each organ in the cranio-caudal, the lateral and the anterior-posterior direction was deduced from the movement of the center of gravity on two-dimensional images. This center of gravity was computed from the volume delineated on sequential 8-mm slices of both sagittal and coronal dynamic series. The largest movements were noticed in the cranio-caudal direction for pancreas and liver (23.7±15.9 mm and 24.4±16.4 mm). The kidneys showed smaller movements in the cranio-caudal direction (left kidney 16.9±6.7 mm and right kidney 16.1±7.9 mm). The movements of the different organs in the anterior-posterior and lateral directions were less pronounced. It is of the greatest importance to be aware of these movements in the planning of a conformal radiation treatment for pancreatic cancer

  1. Does the IMRT technique allow improvement of treatment plans (e.g. lung sparing) for lung cancer patients with small lung volume: a planning study

    International Nuclear Information System (INIS)

    Komosinska, K.; Kepka, L.; Gizynska, M.; Zawadzka, A.

    2008-01-01

    Aim: We evaluated whether intensity-modulated radiation therapy (IMRT) may offer any advantages in comparison with three-dimensional conformal radiotherapy (3D-CRT) for patients with small lung volume (SLV). Methods: Treatment planning was performed for 10 NSCLC patients with the smallest lung volume (mean: 2241 cc) among 200 patients from our database. For each patient 3D-CRT and IMRT plans were prepared. The goal was to deliver 66 Gy/33 fractions, with dose constraints: mean lung dose (MLD) < 20 Gy, V20 < 35%; spinal cord - Dmax < 45 Gy. When the plan could not meet these criteria, total dose was reduced. The 3D-CRT and IMRT plans were compared. We investigated: prescribed dose, coverage and conformity indices, MLD, V5-V65 in the lung. Results: In 4 out of 10 plans, 3D-CRT did not allow 66 Gy to be delivered, because of predicted pulmonary toxicity. These 4 cases included 3 for which we did not reach 66 Gy with IMRT; still, for these 3 plans the total dose was increased by an average of 9 Gy with IMRT in comparison with 3D-CRT. Coverage indices were similar for both techniques. Conformity indices were better for IMRT plans. MLD was lower in five IMRT and two 3D-CRT plans if equal doses were delivered. The decrease in MLD was seen for cases with large PTV and high PTV/lung volume ratio. Lung V5 was lower for all 3D-CRT plans, 47% vs. 57% for IMRT; V15 and above were larger for 3D-CRT Conclusion: In the planning study, IMRT seems to be a promising technique for cases with SLV, especially when associated with large PT V. (authors)

  2. Clinical Applications of 3-D Conformal Radiotherapy

    Science.gov (United States)

    Miralbell, Raymond

    Although a significant improvement in cancer cure (i.e. 20% increment) has been obtained in the last 2-3 decades, 30-40% of patients still fail locally after curative radiotherapy. In order to improve local tumor control rates with radiotherapy high doses to the tumor volume are frequently necessary. Three-dimensional conformal radiation therapy (3-D CRT) is used to denote a spectrum of radiation planning and delivery techniques that rely on three-dimensional imaging to define the target (tumor) and to distinguish it from normal tissues. Modern, high-precision radiotherapy (RT) techniques are needed in order to implement the goal of optimal tumor destruction delivering minimal dose to the non-target normal tissues. A better target definition is nowadays possible with contemporary imaging (computerized tomography, magnetic resonance imaging, and positron emission tomography) and image registration technology. A highly precise dose distributions can be obtained with optimal 3-D CRT treatment delivery techniques such as stereotactic RT, intensity modulated RT (IMRT), or protontherapy (the latter allowing for in-depth conformation). Patient daily set-up repositioning and internal organ immobilization systems are necessary before considering to undertake any of the above mentioned high-precision treatment approaches. Prostate cancer, brain tumors, and base of skull malignancies are among the sites most benefitting of dose escalation approaches. Nevertheless, a significant dose reduction to the normal tissues in the vicinity of the irradiated tumor also achievable with optimal 3-D CRT may also be a major issue in the treatment of pediatric tumors in order to preserve growth, normal development, and to reduce the risk of developing radiation induced diseases such as cancer or endocrinologic disorders.

  3. Endoscopic treatment of multilocular walled-off pancreatic necrosis with the multiple transluminal gateway technique.

    Science.gov (United States)

    Jagielski, Mateusz; Smoczyński, Marian; Adrych, Krystian

    2017-06-01

    The development of minimally invasive techniques allowed access to the necrotic cavity through transperitoneal, retroperitoneal, transmural and transpapillary routes. The choice of access to walled-off pancreatic necrosis (WOPN) should depend not only on the spread of necrosis, but also on the experience of the clinical center. Herein we describe treatment of a patient with multilocular symptomatic walled-off pancreatic necrosis using minimally invasive techniques. The single transmural access (single transluminal gateway technique - SGT) to the necrotic collection of the patient was ineffective. The second gastrocystostomy was performed using the same minimally invasive technique as an extra way of access to the necrosis (multiple transluminal gateway technique - MTGT). In the described case the performance of the new technique consisting in endoscopic multiplexing transmural access (MTGT) was effective enough and led to complete recovery of the patient.

  4. Treatment-Related Morbidity in Prostate Cancer: A Comparison of 3-Dimensional Conformal Radiation Therapy With and Without Image Guidance Using Implanted Fiducial Markers

    International Nuclear Information System (INIS)

    Singh, Jasmeet; Greer, Peter B.; White, Martin A.; Parker, Joel; Patterson, Jackie; Tang, Colin I.; Capp, Anne; Wratten, Christopher; Denham, James W.

    2013-01-01

    Purpose: To estimate the prevalence of rectal and urinary dysfunctional symptoms using image guided radiation therapy (IGRT) with fiducials and magnetic resonance planning for prostate cancer. Methods and Materials: During the implementation stages of IGRT between September 2008 and March 2010, 367 consecutive patients were treated with prostatic irradiation using 3-dimensional conformal radiation therapy with and without IGRT (non-IGRT). In November 2010, these men were asked to report their bowel and bladder symptoms using a postal questionnaire. The proportions of patients with moderate to severe symptoms in these groups were compared using logistic regression models adjusted for tumor and treatment characteristic variables. Results: Of the 282 respondents, the 154 selected for IGRT had higher stage tumors, received higher prescribed doses, and had larger volumes of rectum receiving high dosage than did the 128 selected for non-IGRT. The follow-up duration was 8 to 26 months. Compared with the non-IGRT group, improvement was noted in all dysfunctional rectal symptoms using IGRT. In multivariable analyses, IGRT improved rectal pain (odds ratio [OR] 0.07 [0.009-0.7], P=.02), urgency (OR 0.27 [0.11-0.63], P=<.01), diarrhea (OR 0.009 [0.02-0.35], P<.01), and change in bowel habits (OR 0.18 [0.06-0.52], P<.010). No correlation was observed between rectal symptom levels and dose-volume histogram data. Urinary dysfunctional symptoms were similar in both treatment groups. Conclusions: In comparison with men selected for non-IGRT, a significant reduction of bowel dysfunctional symptoms was confirmed in men selected for IGRT, even though they had larger volumes of rectum treated to higher doses

  5. Reflections on Conformal Spectra

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    We use modular invariance and crossing symmetry of conformal field theory to reveal approximate reflection symmetries in the spectral decompositions of the partition function in two dimensions in the limit of large central charge and of the four-point function in any dimension in the limit of large scaling dimensions Δ0 of external operators. We use these symmetries to motivate universal upper bounds on the spectrum and the operator product expansion coefficients, which we then derive by independent techniques. Some of the bounds for four-point functions are valid for finite Δ0 as well as for large Δ0. We discuss a similar symmetry in a large spacetime dimension limit. Finally, we comment on the analogue of the Cardy formula and sparse light spectrum condition for the four-point function. (based on 1510.08772 with Kim & Ooguri). This seminar will be given via videolink

  6. Application of analysis techniques cause root for evaluation of non-conformities; Aplicacion de las tecnicas de analisis causa raiz a la evaluacion de disconformidades

    Energy Technology Data Exchange (ETDEWEB)

    Domingo Cruz, C.; Gonzalvo, A.

    2012-07-01

    The analysis techniques cause root are used in the evaluation of incidents at nuclear power plants. Its purpose is to determine the ultimate cause to establish corrective actions to prevent these events or other similar in the future. If the consequences are greater should make a more detailed study to determine the WHAT, HOW and WHY the incident.

  7. Viscous conformal gauge theories

    DEFF Research Database (Denmark)

    Toniato, Arianna; Sannino, Francesco; Rischke, Dirk H.

    2017-01-01

    We present the conformal behavior of the shear viscosity-to-entropy density ratio and the fermion-number diffusion coefficient within the perturbative regime of the conformal window for gauge-fermion theories.......We present the conformal behavior of the shear viscosity-to-entropy density ratio and the fermion-number diffusion coefficient within the perturbative regime of the conformal window for gauge-fermion theories....

  8. Conformal Einstein spaces

    International Nuclear Information System (INIS)

    Kozameh, C.N.; Newman, E.T.; Tod, K.P.

    1985-01-01

    Conformal transformations in four-dimensional. In particular, a new set of two necessary and sufficient conditions for a space to be conformal to an Einstein space is presented. The first condition defines the class of spaces conformal to C spaces, whereas the last one (the vanishing of the Bach tensor) gives the particular subclass of C spaces which are conformally related to Einstein spaces. (author)

  9. To compare effects of maitland and mulligan mobilization techniques in the treatment of frozen shoulder

    International Nuclear Information System (INIS)

    Haider, R.; Ahmad, A.

    2014-01-01

    To compare the role of Maitland mobilization and Mulligan's mobilization techniques in treatment of frozen shoulder and its possible effect in early gaining of ROM and Pain management. Methods: This was a randomized control trial conducted at Department of Physiotherapy ana Orthopedics unit I, KEMU / Mayo Hospital, Lahore. There were two group of patients each group contained 30 patients. Patients were treated with Mulligan's technique in Group - A and with Maitland manual therapy technique in Group - B. Patients in both treatment groups were followed till 6 weeks and improvement in range of motion parameters were recorded at every follow up visit of the patients. SPSS was used for data entry and analysis. Results: In the study 60 patients were enrolled. Mean age of Group - A patients was 46.23 ± 9.71 years, and mean age of Group - B patients was 47 ± 9.21 years. In Group - A 14 patients duration of onset was 8 weeks, 4 patients duration of onset was 10 weeks and 12 patients duration of onset was 12 weeks. In Group - B 14 patients duration of onset was 8 weeks, 8 patients duration of onset was 10 weeks and 12 weeks each respectively. It was observed that patients who were treated with Mulligan technique their abduction and flexion was improved greatly as compared to those who were treated with Maitland technique. Patients who were treated with Mulligan technique their flex- ion was improved greatly as compared to those who were treated with Maitland technique. At 6th week mean extension in Maitland's treatment group was 52.50 ± 8.66 where as that Mulligan's treatment group was 52.00 ± 7.58. It was observed that patients in both treatment groups had same improvement in extension and it was statistically same. In both treatment groups patients had same improvement in medial rotation and it was statistically same. At 6th week mean lateral rotation in both treatment groups was 42.65 ± 24.47 and 53.50 ± 23.03. It was observed that patients in

  10. Skull base chordomas: treatment outcome and prognostic factors in adult patients following conformal treatment with 3D planning and high dose fractionated combined proton and photon radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Munzenrider, J E; Hug, E; McManus, P; Adams, J; Efird, J; Liebsch, N J

    1995-07-01

    Purpose: To report treatment outcome and prognostic factors for local recurrence-free survival and overall survival in adult patients with skull base chordomas treated with 3D planning and high dose fractionated combined proton and photon radiation therapy. Methods and Materials: From 1975 through 1993, 132 adult patients with skull base chordomas were treated with fractionated combined proton and photon radiation therapy. Seventy five patients (57%) were male and 57 (43%) female. Age ranged from 19 to 80 years (median 45.5 years). All pathology was verified at MGH by a single pathologist. Ninety six had non-chondroid (NCC) and 36 chondroid chordomas (CC), respectively. Median prescribed dose was 68.7 CGE (CGE, Cobalt Gray-equivalent: proton Gy X RBE 1.1 + photon Gy), ranging from 36 to 79.2 CGE; 95% received {>=} 66.6 CGE. Between 70 and 100% of the dose was given with the 160 MeV proton beam at the Harvard Cyclotron. 3D CT-based treatment planning has been employed in all patients treated since 1980. Median follow-up was 46 months (range 2-158 months). Results: Treatment outcome was evaluated in terms of local recurrence-free survival (LRFS) and disease specific survival (DSS), as well as treatment-related morbidity. Local failure (LF), defined as progressive neurological deficit with definite increase in tumor volume on CT or MRI scan, occurred in 39 patients (29.5%). LF was more common among women than among men:(26(57)) (46%) vs (13(75)) (17%), respectively. Thirty three of the 39 LF were seen in non-chondroid chordoma patients, with 6 occurring in patients with the chondroid variant (34% of NCC and 17% of CC), respectively. Distant metastasis was documented in 8 patients. LRFS was 81 {+-} 5.8%, 59 {+-} 8.3%, and 43 {+-} 10.4%, and DSS was 94 {+-} 3.6%, 80 {+-} 6.7%, and 50 {+-} 10.7% at 36, 60, and 96 months, respectively, for the total group. LRFS and DSS were not significantly different for patients with NCC than those with CC (p > .05). Gender was

  11. Craniospinal irradiation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Scarlatescu, Ioana, E-mail: scarlatescuioana@gmail.com; Avram, Calin N. [Faculty of Physics, West University of Timisoara, Bd. V. Parvan 4, 300223 Timisoara (Romania); Virag, Vasile [County Hospital “Gavril Curteanu” - Oradea (Romania)

    2015-12-07

    In this paper we present one treatment plan for irradiation cases which involve a complex technique with multiple beams, using the 3D conformational technique. As the main purpose of radiotherapy is to administrate a precise dose into the tumor volume and protect as much as possible all the healthy tissues around it, for a case diagnosed with a primitive neuro ectoderm tumor, we have developed a new treatment plan, by controlling one of the two adjacent fields used at spinal field, in a way that avoids the fields superposition. Therefore, the risk of overdose is reduced by eliminating the field divergence.

  12. The technique of «Subliminal verbal suggestion for the treatment of [pseudo]obsessions»

    Directory of Open Access Journals (Sweden)

    N. V. Danilevska

    2016-03-01

    Full Text Available [Pseudo]obsessions therapy in patients with endogenous diseases of schizophrenic round accompanied with difficulties, caused by both psycho etio pathogenetic features of the disease. Disadvantages of the existing methods of therapy are associated with therapeutic conflict between two nosologies. Aim: to develop and test etiopsychopathogenetic technique "Subliminal verbal suggestion for the treatment of [pseudo]obsessions" as a subsidiary method of treatment of schizophrenia patients with [pseudo] obsessions in the structure of the disease. Methods and results. 137 patients who underwent hospital treatment 65 schizophrenia patients (F20 with the [pseudo]obsessive symptoms in the structure of the disease were examined on the basis of Public Health Institution «Regional clinical mental hospital» of the Zaporizhzhian regional council. 30 patients received standard pharmacotherapy (antipsychotic drugs according to clinical protocols that was combined with proposed technique "Subliminal verbal suggestion for the treatment of [pseudo]obsessions". The comparison group consisted of 35 patients treated with the use of standard pharmacotherapy: antipsychotic drugs. The next methods were used: medical history assessment, follow-up, clinical-psychopathological, psychodiagnostic. "Subliminal verbal suggestion for the treatment of [pseudo]obsessions" technique was developed. This technique is a combination of suggestion in the waking state and neurolinguistic programming, implemented with specially compiled auditory complex listening. The main therapeutic component s realized through the subthreshold perception of the verbal formulas that are unavailable to awareness. The technique consists of two components – primary and secondary, and three stages. The methodology was tested, its therapeutic efficacy was confirmed. Conclusion. "Subliminal verbal suggestion for the treatment of [pseudo]obsessions" technique was developed as a subsidiary method of the

  13. Impact of Volumetric Modulated Arc Therapy Technique on Treatment With Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Qiu Jianjian; Chang Zheng; Wu, Q. Jackie; Yoo, Sua; Horton, Janet; Yin Fangfang

    2010-01-01

    Purpose: To investigate the technical feasibility of volumetric modulated arc therapy (V-MAT) in the delivery of partial breast irradiation (PBI). Methods and Materials: V-MAT and the standard, three-dimensional conformal radiotherapy (3D-CRT), were compared retrospectively in 8 patients previously treated with PBI. These patients' plans were replanned with a single partial arc using V-MAT that included partial blocking to minimize normal tissue dose. Dosimetric parameters were calculated to evaluate plan quality. Quality assurance studies included verifying both the point and the multiple planar doses. Total monitor units and delivery time were also evaluated, and collision clearance was analyzed. Results: Volumes of ipsilateral lung irradiated to 10 Gy (V10) and 20 Gy (V20) by V-MAT were significantly less than those of 3D-CRT (p = 0.03 for V10 and p = 0.025 for V20). The volume of ipsilateral breast irradiated to 5 Gy was significantly less by using V-MAT than with 3D-CRT (p = 0.02), with a ratio of integrated dose of <1.00. The total mean monitor units (489 ± 38) for V-MAT were significantly less than those for 3D-CRT (634 ± 123) (p = 0.017), with a 23% reduction. The average machine delivery time was 1.21 ± 0.10 min for the V-MAT plans and 6.28 ± 1.40 min for the 3D-CRT plans, resulting in a reduction factor of 80.1%. The conformity indexes were 1.3 in the V-MAT plans and 1.5 in the 3D-CRT plans (p = 0.102). Conclusions: V-MAT technology is feasible for PBI patients. Compared to a conventional 3D-CRT technique, it is more efficient, offers equivalent or better dose conformity, delivers lower doses to the ipsilateral lung and breast, and may potentially reduce intrafractional motion.

  14. Research on monitoring and management information integration technique in waste treatment and management

    International Nuclear Information System (INIS)

    Kong Jinsong; Yu Ren; Mao Wei

    2013-01-01

    The integration of the waste treatment process and the device status monitoring information and management information is a key problem required to be solved in the information integration of the waste treatment and management. The main content of the monitoring and management information integration is discussed in the paper. The data exchange techniques, which are based on the OPC, FTP and data push technology, are applied to the different monitoring system respectively, according to their development platform, to realize the integration of the waste treatment process and device status monitoring information and management information in a waste treatment center. (authors)

  15. Superspace conformal field theory

    Energy Technology Data Exchange (ETDEWEB)

    Quella, Thomas [Koeln Univ. (Germany). Inst. fuer Theoretische Physik; Schomerus, Volker [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2013-07-15

    Conformal sigma models and WZW models on coset superspaces provide important examples of logarithmic conformal field theories. They possess many applications to problems in string and condensed matter theory. We review recent results and developments, including the general construction of WZW models on type I supergroups, the classification of conformal sigma models and their embedding into string theory.

  16. Superspace conformal field theory

    International Nuclear Information System (INIS)

    Quella, Thomas

    2013-07-01

    Conformal sigma models and WZW models on coset superspaces provide important examples of logarithmic conformal field theories. They possess many applications to problems in string and condensed matter theory. We review recent results and developments, including the general construction of WZW models on type I supergroups, the classification of conformal sigma models and their embedding into string theory.

  17. Triple-Tube-Ostomy: A Novel Technique for the Surgical Treatment of Iatrogenic Duodenal Perforation

    Directory of Open Access Journals (Sweden)

    Nobuaki Fujikuni

    2011-12-01

    Full Text Available Although duodenal perforation is currently an infrequent complication of medical procedures, its incidence in the future predictably will increase as endoscopic treatment of duodenal neoplasms becomes more frequently used. In some cases, duodenal perforation is difficult to treat even surgically. We report here a novel technique called ‘triple-tube-ostomy’ for the treatment of iatrogenic duodenal perforation. Since November 2009, there have been three cases of iatrogenic perforation of the duodenum, due to various causes, which we have treated with our novel technique. The main principles of the technique are biliary diversion, decompression of the duodenum, and early enteral nutrition. All patients who underwent the triple-tube-ostomy procedure had good postoperative courses, with few complications. The novel surgical technique we describe in this report is safe, reliable, easy to learn and perform, and led to a good postoperative course in all cases where we performed it.

  18. Treatment of a case of subacute lumbar compartment syndrome using the Graston technique.

    Science.gov (United States)

    Hammer, Warren I; Pfefer, Mark T

    2005-01-01

    To discuss subacute lumbar compartment syndrome and its treatment using a soft tissue mobilization technique. A patient presented with low back pain related to exercise combined with prolonged flexion posture. The symptoms were relieved with rest and lumbar extension. The patient had restrictive lumbar fascia in flexion and rotation and no neurological deficits. The restrictive lumbar posterior fascial layers and adjoining restrictive fascia (thoracic, gluteal, hamstring) were treated with a form of instrument-assisted soft tissue mobilization called the Graston technique. Restoration of fascial extensibility and resolution of the complaint occurred after 6 treatment visits. The posterior spinal fascial compartments may be responsible for intermittent lower back pain. Functional clinical tests can be employed to determine whether the involved fascia is abnormally restrictive. Treatment directed at the restrictive fascia using this soft tissue technique may result in improved fascial functional testing and reduction of symptoms.

  19. Combined use of ultrasonic liposuction with the pull-through technique for the treatment of gynecomastia.

    Science.gov (United States)

    Hammond, Dennis C; Arnold, Jame F; Simon, Amy M; Capraro, Philippe A

    2003-09-01

    The authors present a method of treatment for gynecomastia that combines the use of two techniques of soft-tissue contouring. This method uses ultrasonic liposuction in conjunction with the pull-through technique of direct excision to effectively remove the fibrofatty tissue of the male breast and the fibrous breast bud through a single 1-cm incision. Fifteen patients were treated in this fashion, and each patient demonstrated a smooth, masculine breast contour with a well-concealed scar, which eliminates the stigma of breast surgery. The procedure is technically straightforward and provides consistent results. It is offered as an additional option for the treatment of gynecomastia.

  20. Surgical techniques for the treatment of carpal ligament injury in the athlete.

    Science.gov (United States)

    Paci, Gabrielle M; Yao, Jeffrey

    2015-01-01

    Treatment of intercarpal ligament injuries in the athlete requires special attention due to several practical and biomechanical considerations. Optimally, the athlete will maintain as much function and range of motion as possible with return to high-impact and load-bearing activity in a timely fashion. Several cutting-edge techniques have arisen in treatment. This article discusses injury patterns in the athlete with scapholunate injury, lunotriquetral injury, scaphotrapezial-trapezoidal injury, and extrinsic ligamentous injury, and the various approaches to addressing these injuries, with a review of the classic as well as newer, innovative techniques. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Frontier of Advanced Accelerator Applications and Medical Treatments Using Nuclear Techniques. Abstract

    International Nuclear Information System (INIS)

    2015-01-01

    To address the challenges of research-based practice, developing advanced accelerator applications, and medical treatments using nuclear tecniqoes, researchers from Rajamakala University of Technology Lanna, Office of Atoms for Peace, and Chiang Mai University have joined in hosting this conference. Nuclear medicine, amedical specialty, diagnoses and treats diseases in a safe and painless way. Nuclear techniques can determine medical information that may otherwise be unavailable, require surgery, or necessitate more expensive and invasive diagnostic tests. Advance in nuclear techniques also offer the potential to detect abnormalities at earlier stages, leasding to earlier treatment and a more successful prognosis.

  2. Conformity Index and Homogeneity Index of the Postoperative Whole Breast Radiotherapy.

    Science.gov (United States)

    Petrova, Deva; Smickovska, Snezana; Lazarevska, Emilija

    2017-10-15

    The treatment of breast cancer involves a multidisciplinary approach in which radiotherapy plays a key role. The conformity index and the homogeneity index are two analysis tools of a treatment plan using conformal radiotherapy. The purpose of this article is an analysis of these two parameters in the assessment of the treatment plans in 58 patients undergoing postoperative radiotherapy of the whole breast. All 58 patients participating in the study had a conservatively treated early-stage breast cancer. The treatment was performed using a standard regimen of fractionation in 25 fractions up to a total dose of 50 Gy. Dose-volume histograms were generated for both plans with and without segmental fields. Pair samples t-test was used. The technique with segmental fields allowed us more homogeneity distribution when compared to standard two tangential field techniques. The HI values were 1.08 ± 0.01 and 1.09 ± 0.01 for segment and technique with two tangential fields (p conformity and the homogeneity index are important tools in the analysis of the treatment plans during radiation therapy in patients with early-stage breast cancer. Adding segment fields in the administration of radiotherapy in patients with conservatively treated breast cancer can lead to improved dosage homogeneity and conformity.

  3. The treatment of tubal pregnancy by interventional technique through uterine artery

    International Nuclear Information System (INIS)

    Li Lizhao; Zhang Yonghui; Chen Zhu; Ge Xiaobing; Li Jiehua

    2004-01-01

    Objective: To study the feasibility and the clinical effect of the treatment of tubule pregnancy by using interventional technique through selective uterine artery. Methods: By using seldinger's method, 48 cases received interventional treatment, followed by perfusion of methotrexate (MTX) 100 mg through Tube 4-5 F. The concentration of serum β-HCG, the changes of pelvic cavity, and the open condition of amnion by ultrasonic examination. Results: The cure rate of 47 cases was 97.92%. No serious reaction. After treatment, the mean time that the serum β-HCG concentration returned to normal was 14-28 days and the mean time was 18 days. Conclusion: The treatment of tubule pregnancy by interventional technique proved no harmful effect to reproductive organs and quick recovery. It is worth spreading

  4. Dosimetric comparison of treatment techniques IMRT and VMAT for breast cancer

    International Nuclear Information System (INIS)

    Urbina, G. L.; Garcia, B. G.

    2015-10-01

    In this study the dosimetric distribution was compared in the different treatment techniques such as Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) in female patients with breast cancer with stage II-B and III-A, 6 cases (both calculated on VMAT and IMRT) were studied, comparison parameter that are taken into account are: compliance rate, homogeneity index, monitor units, volume dose 50 Gy (D-50%) and 5 Gy (D-5%) volume dose. Comparisons are made in primary tumor volume to optimize treatment in patients with breast cancer, with IMRT using Step, Shoot and VMAT Monte Carlo algorithm, in addition to the organs at risk; the concern to make this work is due to technological advances in radiotherapy and the application of new treatment techniques, that increase the accuracy allowing treatment dose climbing delivering a higher dose to the patient. (Author)

  5. Orange Peel Excision of Gland: A Novel Surgical Technique for Treatment of Gynecomastia.

    Science.gov (United States)

    S S, Shirol

    2016-12-01

    Gynecomastia is a common aesthetic problem faced by men with reported incidence as high as 65% with serious psychosocial impact. Although various techniques of liposculpture combined with glandular excision is the standard of treatment, many of the glandular excision techniques have inherent limitations and complications such as leaving a long scar, long operative time, contour abnormalities, and increased risk of hematoma. Here, we describe an innovative "the orange peel excision of gland (OPEG) technique" which overcomes these limitations with excellent cosmetic results. A total of 38 breasts were operated in 20 patients (18 bilateral and 2 unilateral). All the patients underwent suction-assisted liposuction and glandular excision under general anesthesia by our OPEG technique. The average operative time per breast was 60 minutes. One patient had a small hematoma which did not require evacuation. The patient satisfaction rate was 95%. The technique has reduced operative time and avoids residual gland and hematoma with excellent aesthetic outcome.

  6. Intensity-Modulated Radiotherapy Causes Fewer Side Effects than Three-Dimensional Conformal Radiotherapy When Used in Combination With Brachytherapy for the Treatment of Prostate Cancer

    International Nuclear Information System (INIS)

    Forsythe, Kevin; Blacksburg, Seth; Stone, Nelson; Stock, Richard G.

    2012-01-01

    Purpose: To measure the benefits of intensity-modulated radiotherapy (IMRT) compared with three-dimensional conformal radiotherapy (3D-CRT) when used in combination with brachytherapy for the treatment of prostate cancer. Methods and Materials: We conducted a retrospective review of all patients with localized prostate cancer who received external-beam radiotherapy (EBRT) in combination with brachytherapy with at least 1 year follow-up (n = 812). Combination therapy consisted of 103 Pd or 125 I implant, followed by a course of EBRT. From 1993 to March 2003 521 patients were treated with 3D-CRT, and from April 2003 to March 2009 291 patients were treated with IMRT. Urinary symptoms were prospectively measured with the International Prostate Symptom Score questionnaire with a single quality of life (QOL) question; rectal bleeding was assessed per the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Radiation Morbidity Scoring Schema. The Pearson χ 2 test was used to compare toxicities experienced by patients who were treated with either IMRT or 3D-CRT. Logistic regression analyses were also performed to rule out possible confounding factors. Results: Within the first 3 months after treatment, patients treated with 3D-CRT scored their urinary symptoms as follows: 19% mild, 44% moderate, and 37% severe; patients treated with IMRT scored their urinary symptoms as follows: 36% mild, 47% moderate, and 17% severe (p < 0.001). The 3D-CRT patients rated their QOL as follows: 35% positive, 20% neutral, and 45% negative; IMRT patients rated their QOL as follows: 51% positive, 18% neutral, and 31% negative (p < 0.001). After 1 year of follow-up there was no longer any difference in urinary morbidity between the two groups. Logistic regression confirmed the differences in International Prostate Symptom Score and QOL in the acute setting (p < 0.001 for both). Grade ≥2 rectal bleeding was reported by 11% of 3D-CRT patients and 7

  7. Air Treatment Techniques for Abatement of Emissions from Intensive Livestock Production

    OpenAIRE

    Melse, R.W.; Ogink, N.W.M.; Rulkens, W.H.

    2009-01-01

    Intensive livestock production is connected with a number of environmental effects, including emissions of ammonia (NH3), greenhouse gases (CH4 and N2O), odour, and particulate matter (PM10 and PM2.5). Possible strategies for emission reduction include feed management, adaptation of housing design, and, in case of mechanically ventilated animal houses, the application of end-of-pipe air treatment, viz acid scrubbers and bioscrubbers. Air treatment techniques can achieve very high emission red...

  8. Non-conformable, partial and conformable transposition

    DEFF Research Database (Denmark)

    König, Thomas; Mäder, Lars Kai

    2013-01-01

    and the Commission regarding a directive’s outcome, play a much more strategic role than has to date acknowledged in the transposition literature. Whereas disagreement of a member state delays conformable transposition, it speeds up non-conformable transposition. Disagreement of the Commission only prolongs...... the transposition process. We therefore conclude that a stronger focus on an effective sanctioning mechanism is warranted for safeguarding compliance with directives....

  9. Conformity index for brain cancer patients

    International Nuclear Information System (INIS)

    Petkovska, Sonja; Tolevska, Cveta; Kraleva, Slavica; Petreska, Elena

    2010-01-01

    The purpose of this study is to present the level of conformity achieved by using 3D conformal radiotherapy for brain cancer patients. Conformity index is a helpful quantitative tool for assessing (evaluating) the quality of a treatment plan. Treatment plans made for ninety patients with brain tumor are worked on this paper. The patients are in supine position and immobilized with thermoplastic masks for the head. Computed tomography data sets with 5 mm scan thickness are used to create a 3D image. All structures of interest are contoured. In order to obtain an optimal dose distribution, treatment fields are fit around target volume with set-up margins of 7mm in each direction. The conformity index values are between 1.21 and 2.04. Value of 1.8 is exceeded in eighteen cases; nine of them are bigger than 1.9 and only three of them are above 2. The target volume for each of these extreme CI values is ideal covered (between 95% and 105% of the prescribed dose). The most acceptable conformity index value in this paper belongs to the plan with the lowest minimal dose (84.7%). It can be concluded that conformity index is necessary but not sufficient factor for assessing radiation treatment plan conformity. To be able to estimate the acceptability of some treatment plan in daily practice, additional information as minimal, maximal and mean dose into target volume, as well as health tissues coverage must be taken into account.(Author)

  10. Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the hypofractionated treatment of high-risk prostate cancer

    International Nuclear Information System (INIS)

    Yuen, Jasper; Rodrigues, George; Trenka, Kristina; Coad, Terry; Yartsev, Slav; D'Souza, David; Lock, Michael; Bauman, Glenn

    2008-01-01

    To compare two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the setting of hypofractionated high-risk prostate cancer treatment. 3DCRT and dIMRT/Helical Tomotherapy(HT) planning with 10 CT datasets was undertaken to deliver 68 Gy in 25 fractions (prostate) and simultaneously delivering 45 Gy in 25 fractions (pelvic lymph node targets) in a single phase. The paradigms of pelvic vessel targeting (iliac vessels with margin are used to target pelvic nodes) and conformal normal tissue avoidance (treated soft tissues of the pelvis while limiting dose to identified pelvic critical structures) were assessed compared to 3DCRT controls. Both dIMRT/HT and 3DCRT solutions were compared to each other using repeated measures ANOVA and post-hoc paired t-tests. When compared to conformal pelvic vessel targeting, conformal normal tissue avoidance delivered more homogenous PTV delivery (2/2 t-test comparisons; p < 0.001), similar nodal coverage (8/8 t-test comparisons; p = ns), higher and more homogenous pelvic tissue dose (6/6 t-test comparisons; p < 0.03), at the cost of slightly higher critical structure dose (D dose , 1–3 Gy over 5/10 dose points; p < 0.03). The dIMRT/HT approaches were superior to 3DCRT in sparing organs at risk (22/24 t-test comparisons; p < 0.05). dIMRT/HT nodal and pelvic targeting is superior to 3DCRT in dose delivery and critical structure sparing in the setting of hypofractionation for high-risk prostate cancer. The pelvic targeting paradigm is a potential solution to deliver highly conformal pelvic radiation treatment in the setting of nodal location uncertainty in prostate cancer and other pelvic malignancies

  11. Treatment of Wide-Neck Bifurcation Aneurysm Using "WEB Device Waffle Cone Technique".

    Science.gov (United States)

    Mihalea, Cristian; Caroff, Jildaz; Rouchaud, Aymeric; Pescariu, Sorin; Moret, Jacques; Spelle, Laurent

    2018-05-01

    The endovascular treatment of wide-neck bifurcation aneurysms can be challenging and often requires the use of adjunctive techniques and devices. We report our first experience of using a waffle-cone technique adapted to the Woven Endoluminal Bridge (WEB) device in a large-neck basilar tip aneurysm, suitable in cases where the use of Y stenting or other techniques is limited due to anatomic restrictions. The procedure was complete, and angiographic occlusion of the aneurysm was achieved 24 hours post treatment, as confirmed by digital subtraction angiography. No complications occurred. The case reported here was not suitable for Y stenting or deployment of the WEB device alone, due to the small caliber of both posterior cerebral arteries and their origin at the neck level. The main advantage of this technique is that both devices have a controlled detachment system and are fully independent. To our knowledge, this technique has not been reported previously and this modality of treatment has never been described in the literature. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. SU-G-TeP1-13: Reclined Total Skin Electron Treatment Technique

    Energy Technology Data Exchange (ETDEWEB)

    Mathew, D; Gerbi, B [University of Minnesota, Minneapolis, MN (United States)

    2016-06-15

    Purpose: The purpose is to describe a new reclined technique for treatment of weakened patients that require total skin electron irradiation. Methods: This technique is a modification of a previously published reclined technique differing in that all six patient positions are treated with the gantry angled 60° from vertically down. The patient is located at a treatment distance of 330 cm SSD along the CA of the beam. The 3/8′ thick Lexan beam spoiler is placed 25 cm from the most proximal surface of the patient for all patient treatment positions. To produce a flat, uniform field of ∼190 cm length, the patient was moved longitudinally by an experimentally determined distance. Kodak EDR2 and EBT3 Radiochromic film were placed around the periphery of the phantom, and OSLs were placed every 30° around the phantom periphery to determine output and surface dose uniformity. A piece of Kodak EDR2 was sandwiched between the two slabs of the 30 cm diameter phantom to determine beam penetration. Results: Field uniformity shifting the patient ±75 cm was ±5% over a treatment span of 190 cm. The dose variation around the periphery of the 30 cm diameter phantom varied by <±5% with the maximum values observed at the 0°-300°, 60° locations with the minimum values at the 30°-330°, 60° locations. Results obtained using Kodak EDR2, EBT3 Radiochromic film, and OSLs agreed to within ±5%. Conclusion: This technique provides a very efficient and convenient means by which to treat the entire skin surface of patients incapable of standing for treatment. It provides a treatment field that is both large and uniform enough for adults along with a convenient way to treat four of the six patient treatment positions. The beam spoiler lies to the side of the patient allowing easy access for patient positioning.

  13. Gel dosimetry for conformal radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G [Department of Physics of the University and INFN, Milan (Italy)

    2005-07-01

    With the continuum development of conformal radio therapies, aimed at delivering high dose to tumor tissue and low dose to the healthy tissue around, the necessities has appeared of suitable improvement of dosimetry techniques giving the possibility of obtaining dose images to be compared with diagnostic images. Also if wide software has been developed for calculating dose distributions in the fields of various radiotherapy units, experimental verifications are necessary, in particular in the case of complex geometries in conformal radiotherapy. Gel dosimetry is a promising method for imaging the absorbed dose in tissue-equivalent phantoms, with the possibility of 3D reconstruction of the spatial dose distribution, with milli metric resolution. Optical imaging of gel dosimeters, based on visible light absorbance analysis, has shown to be a reliable technique for achieving dose distributions. (Author)

  14. The treatment of muscle tension dysphonia: a comparison of two treatment techniques by means of an objective multiparameter approach.

    Science.gov (United States)

    Van Lierde, Kristiane M; De Bodt, Marc; Dhaeseleer, Evelien; Wuyts, Floris; Claeys, Sofie

    2010-05-01

    The purpose of the present study is to measure the effectiveness of two treatment techniques--vocalization with abdominal breath support and manual circumlaryngeal therapy (MCT)--in patients with muscle tension dysphonia (MTD). The vocal quality before and after the two treatment techniques was measured by means of the dysphonia severity index (DSI), which is designed to establish an objective and quantitative correlate of the perceived vocal quality. The DSI is based on the weighted combination of the following set of voice measurements: maximum phonation time (MPT), highest frequency, lowest intensity, and jitter. The repeated-measures analysis of variance (ANOVA) revealed a significant difference between the objective overall vocal quality before and after MCT. No significant differences were measured between the objective overall vocal quality before and after vocalization with abdominal breath support. This study showed evidence that MCT is an effective treatment technique for patients with elevated laryngeal position, increased laryngeal muscle tension, and MTD. The precise way in which MCT has an effect on vocal quality has not been addressed in this experiment, but merits study. Further research into this topic could focus on electromyography (EMG) recordings in relation to vocal improvements with larger sample of subjects. (c) 2010 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  15. A 3D technique for simulation of irregular electron treatment fields using a digital camera

    International Nuclear Information System (INIS)

    Bassalow, Roustem; Sidhu, Narinder P.

    2003-01-01

    Cerrobend inserts, which define electron field apertures, are manufactured at our institution using perspex templates. Contours are reproduced manually on these templates at the simulator from the field outlines drawn on the skin or mask of a patient. A previously reported technique for simulation of electron treatment fields uses a digital camera to eliminate the need for such templates. However, avoidance of the image distortions introduced by non-flat surfaces on which the electron field outlines were drawn could only be achieved by limiting the application of this technique to surfaces which were flat or near flat. We present a technique that employs a digital camera and allows simulation of electron treatment fields contoured on an anatomical surface of an arbitrary three-dimensional (3D) shape, such as that of the neck, extremities, face, or breast. The procedure is fast, accurate, and easy to perform

  16. Could 3-D conformal radiotherapy improve the overall survival for non-small cell lung cancer?

    International Nuclear Information System (INIS)

    Giraud, P.; Helfre, S.; Lavole, A.; Rosenwald, J.C.; Cosset, J.M.

    2002-01-01

    The conformal radiotherapy approach, three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT), is based on modern imaging modalities, efficient 3-D treatment planning systems, sophisticated immobilization devices and demanding quality assurance and treatment verification. The main goal of conformal radiotherapy is to ensure a high dose distribution tailored to the limits of the target volume while reducing exposure of healthy tissues. These techniques would then allow a further dose escalation increasing local control and survival. Non-small cell lung cancer (NSCLC) is one of the most difficult malignant tumors to be treated. It combines geometrical difficulties due to respiratory motion, and number of low tolerance neighboring organs, and dosimetric difficulties because of the presence of huge inhomogeneities. This localization is an attractive and ambitious example for the evaluation of new techniques. However, the published clinical reports in the last years described very heterogeneous techniques and, in the absence of prospective randomized trials, it is somewhat difficult at present to evaluate the real benefits drawn from those conformal radiotherapy techniques. After reviewing the rationale for 3DCRT for NSCLC, this paper will describe the main studies of 3DCRT, in order to evaluate its impact on lung cancer treatment Then the current state-of-the-art of IMRT and the last technical and therapeutic innovations in NSCL will be discussed. (authors)

  17. Intensity modulated conformal radiotherapy

    International Nuclear Information System (INIS)

    Noel, Georges; Moty-Monnereau, Celine; Meyer, Aurelia; David, Pauline; Pages, Frederique; Muller, Felix; Lee-Robin, Sun Hae; David, Denis Jean

    2006-12-01

    This publication reports the assessment of intensity-modulated conformal radiotherapy (IMCR). This assessment is based on a literature survey which focussed on indications, efficiency and safety on the short term, on the risk of radio-induced cancer on the long term, on the role in the therapeutic strategy, on the conditions of execution, on the impact on morbidity-mortality and life quality, on the impact on the health system and on public health policies and program. This assessment is also based on the opinion of a group of experts regarding the technical benefit of IMCR, its indications depending on the cancer type, safety in terms of radio-induced cancers, and conditions of execution. Before this assessment, the report thus indicates indications for which the use of IMCR can be considered as sufficient or not determined. It also proposes a technical description of IMCR and helical tomo-therapy, discusses the use of this technique for various pathologies or tumours, analyses the present situation of care in France, and comments the identification of this technique in foreign classifications

  18. Treatment of a Developmental Groove and Supernumerary Root Using Guided Tissue Regeneration Technique

    Directory of Open Access Journals (Sweden)

    Zahra Alizadeh Tabari

    2016-01-01

    Full Text Available Introduction. The radicular groove is a developmental groove which is usually found on the palatal or lateral aspects of the maxillary incisor teeth. The present case is a maxillary lateral incisor with a small second root and a deep radicular groove. The developmental groove caused a combined periodontal-endodontic lesion. Methods. Case was managed using a combined treatment procedure involving nonsurgical root canal therapy and surgical periodontal treatment. After completion of root canal treatment, guided tissue regeneration (GTR was carried out using decalcified freeze dried bone allograft (DFDBA and a bioabsorbable collagenous membrane. Tooth also was splinted for two months. Results. After 12 months the tooth was asymptomatic. The periapical radiolucency disappeared and probing depth did not exceed 3 mm. Conclusion. Combined treatment procedure involving nonsurgical root canal therapy and surgical periodontal regenerative treatment can be a predictable technique in treating combined endodontic-periodontal lesions caused by radicular groove.

  19. Chiropractic treatment of lateral epicondylitis: a case report utilizing active release techniques.

    Science.gov (United States)

    Gliedt, Jordan A; Daniels, Clinton J

    2014-06-01

    The purpose of this report is to describe the chiropractic management of a case of lateral epicondylitis with active release techniques (ART). A 48-year-old white man presented to a chiropractic clinic with a complaint of left lateral elbow pain that began 2 years previous with insidious onset. The patient reported an inability to play 18 consecutive holes of golf due to the pain. Treatment consisted of 5 sessions of ART (a soft tissue technique that is applied to muscles, fascia, tendons, ligaments, and nerves) applied to the left elbow soft tissue over a duration of 3 weeks. The patient reported an absence of pain and ability to consistently play 18 consecutive holes of golf up to 3 times per week at 4 and 8 weeks post-treatment. This patient with lateral epicondylitis responded favorably to chiropractic treatment using the application of ART, as demonstrated by reduced pain and increased functional outcomes.

  20. Surgical techniques for the treatment of ankyloglossia in children: a case series

    Directory of Open Access Journals (Sweden)

    Marina Azevedo JUNQUEIRA

    2014-06-01

    Full Text Available This paper reports a series of clinical cases of ankyloglossia in children, which were approached by different techniques: frenotomy and frenectomy with the use of one hemostat, two hemostats, a groove director or laser. Information on the indications, contraindications, advantages and disadvantages of the techniques was also presented. Children diagnosed with ankyloglossia were subjected to different surgical procedures. The choice of the techniques was based on the age of the patient, length of the frenulum and availability of the instruments and equipment. All the techniques presented are successful for the treatment of ankyloglossia and require a skilled professional. Laser may be considered a simple and safe alternative for children while reducing the amount of local anesthetics needed, the bleeding and the chances of infection, swelling and discomfort.

  1. Integrating Organ Motion and Setup Uncertainty into Optimization of Modulated Electron Beam Treatment of Breast Cancer

    National Research Council Canada - National Science Library

    Pawlicki, Todd

    2003-01-01

    ... of modulated electron radiotherapy (MERT) treatment of the breast. The premise is that MERT treatments will deliver a more conformal dose to the breast while minimizing the dose to normal tissues over conventional photon techniques...

  2. Comparison of online IGRT techniques for prostate IMRT treatment: Adaptive vs repositioning correction

    International Nuclear Information System (INIS)

    Thongphiew, Danthai; Wu, Q. Jackie; Lee, W. Robert; Chankong, Vira; Yoo, Sua; McMahon, Ryan; Yin Fangfang

    2009-01-01

    This study compares three online image guidance techniques (IGRT) for prostate IMRT treatment: bony-anatomy matching, soft-tissue matching, and online replanning. Six prostate IMRT patients were studied. Five daily CBCT scans from the first week were acquired for each patient to provide representative ''snapshots'' of anatomical variations during the course of treatment. Initial IMRT plans were designed for each patient with seven coplanar 15 MV beams on a Eclipse treatment planning system. Two plans were created, one with a PTV margin of 10 mm and another with a 5 mm PTV margin. Based on these plans, the delivered dose distributions to each CBCT anatomy was evaluated to compare bony-anatomy matching, soft-tissue matching, and online replanning. Matching based on bony anatomy was evaluated using the 10 mm PTV margin (''bone10''). Soft-tissue matching was evaluated using both the 10 mm (''soft10'') and 5 mm (''soft5'') PTV margins. Online reoptimization was evaluated using the 5 mm PTV margin (''adapt''). The replanning process utilized the original dose distribution as the basis and linear goal programming techniques for reoptimization. The reoptimized plans were finished in less than 2 min for all cases. Using each IGRT technique, the delivered dose distribution was evaluated on all 30 CBCT scans (6 patientsx5CBCT/patient). The mean minimum dose (in percentage of prescription dose) to the CTV over five treatment fractions were in the ranges of 99%-100%(SD=0.1%-0.8%), 65%-98%(SD=0.4%-19.5%), 87%-99%(SD=0.7%-23.3%), and 95%-99%(SD=0.4%-10.4%) for the adapt, bone10, soft5, and soft10 techniques, respectively. Compared to patient position correction techniques, the online reoptimization technique also showed improvement in OAR sparing when organ motion/deformations were large. For bladder, the adapt technique had the best (minimum) D90, D50, and D30 values for 24, 17, and 15 fractions out of 30 total fractions, while it also had the best D90, D50, and D30 values for

  3. Power-assisted liposuction and the pull-through technique for the treatment of gynecomastia.

    Science.gov (United States)

    Lista, Frank; Ahmad, Jamil

    2008-03-01

    Gynecomastia is a common condition affecting many adolescent and adult males. Surgical techniques utilizing a variety of incisions, excisions, suction-assisted lipectomy, ultrasound-assisted liposuction, power-assisted liposuction, or some combination of these methods have been used in the treatment of gynecomastia. This article describes the authors' method of using power-assisted liposuction and the pull-through technique to treat gynecomastia. This technique involves the use of power-assisted liposuction to remove fatty breast tissue. The pull-through technique is then performed utilizing several instruments to sever the subdermal attachments of fibroglandular breast tissue; this tissue is removed through the incision used for liposuction. Finally, power-assisted liposuction is performed again to contour the remaining breast tissue. A chart review of 99 consecutive patients (197 breasts) treated between January of 2003 and November of 2006 was performed. Ninety-six patients (192 breasts) were successfully treated using this technique. Power-assisted liposuction was performed in all cases, and the average volume aspirated per breast was 459 ml (range, 25 to 1400 ml). Using the pull-through technique, the authors were able to remove between 5 and 70 g of tissue per breast. Complications were minimal (1.0 percent of breasts), and no revisions were required. Since January of 2003, the authors have used this technique to successfully treat 97 percent of their gynecomastia patients. Combining power-assisted liposuction and the pull-through technique has proven to be a versatile approach for the treatment of gynecomastia and consistently produces a naturally contoured male breast while resulting in a single inconspicuous scar.

  4. Dosimetric study of volumetric arc modulation with RapidArc and intensity-modulated radiotherapy in patients with cervical cancer and comparison with 3-dimensional conformal technique for definitive radiotherapy in patients with cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Guy, Jean-Baptiste [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France); Falk, Alexander T. [Department of Radiation Oncology, Centre Antoine Lacassagne, Nice (France); Auberdiac, Pierre [Department of Radiation Oncology, Clinique Claude Bernard, Albi (France); Cartier, Lysian; Vallard, Alexis [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France); Ollier, Edouard [Department of Pharmacology-Toxicology, Centre Hospitalier Universitaire de Saint-Etienne, Saint-Priest en Jarez (France); Trone, Jane-Chloé; Khodri, Moustapha [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France); Chargari, Cyrus [Department of Radiation Oncology, Hôpital d’instruction de Armées du Val-de-Grâce, Paris (France); Magné, Nicolas, E-mail: nicolas.magne@icloire.fr [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France)

    2016-04-01

    Introduction: For patients with cervical cancer, intensity-modulated radiation therapy (IMRT) improves target coverage and allows dose escalation while reducing the radiation dose to organs at risk (OARs). In this study, we compared dosimetric parameters among 3-dimensional conformal radiotherapy (3D-CRT), “step-and-shoot” IMRT, and volumetric intensity-modulated arc radiotherapy (VMAT) in a series of patients with cervical cancer receiving definitive radiotherapy. Computed tomography (CT) scans of 10 patients with histologically proven cervical cancer treated with definitive radiation therapy (RT) from December 2008 to March 2010 at our department were selected for this study. The gross tumor volume (GTV) and clinical target volume (CTV) were delineated following the guidelines of the Gyn IMRT consortium that included cervix, uterus, parametrial tissues, and the pelvic nodes including presacral. The median age was 57 years (range: 30 to 85 years). All 10 patients had squamous cell carcinoma with Federation of Gynecology and Obstetrics (FIGO) stage IB-IIIB. All patients were treated by VMAT. OAR doses were significantly reduced for plans with intensity-modulated technique compared with 3D-CRT except for the dose to the vagina. Between the 2 intensity-modulated techniques, significant difference was observed for the mean dose to the small intestine, to the benefit of VMAT (p < 0.001). There was no improvement in terms of OARs sparing for VMAT although there was a tendency for a slightly decreased average dose to the rectum: − 0.65 Gy but not significant (p = 0.07). The intensity modulation techniques have many advantages in terms of quality indexes, and particularly OAR sparing, compared with 3D-CRT. Following the ongoing technologic developments in modern radiotherapy, it is essential to evaluate the intensity-modulated techniques on prospective studies of a larger scale.

  5. A Comparative Dosimetric Study of Adjuvant 3D Conformal Radiotherapy for Operable Stomach Cancer Versus AP-PA Conventional Radiotherapy in NCI-Cairo

    International Nuclear Information System (INIS)

    El-Hossiny, H.A.; Diab, N.A.; El-Taher, M.M.

    2009-01-01

    This study was to compare this multiple field conformal technique to the AP-PA technique with respect to target volume coverage and dose to normal tissues. Materials and Methods: Seventeen patients with stages II-III denocarcinoma of the stomach were treated with adjuvant postoperative chemoradiotherapy presented to radiotherapy department in National Cancer Institute, Cairo in period between February 2009 to March 2010 using 3D conformal radiotherapy technique that consisted of a mono isocentric arrangement employing 4-6 radiation fields. For each patient, a second radiotherapy treatment plan was done using an antroposterior (AP-PA) fields, the two techniques were then compared using dose volume histogram (DVH) analysis. Results: Comparing different DVHs, it was found that the planning target volume (PTV) was adequately covered in both (3D and 2D) plans while the left kidney and spinal cord demonstrate lower radiation doses on using the conformal technique. The liver doses is higher in the 3D tecq, but still well below liver tolerance. Conclusions: Both 3D conformal radiotherapy and AP-PA conventional techniques doses are within range of normal tissues tolerance. Regarding the left kidney and spinal cord the 3D conformal radiotherapy is superior than the AP-PA conventional techniques but with higher doses to the liver in the 3D conformal radiotherapy compared to the AP-PA conventional techniques

  6. Endoluminal brachytherapy in the treatment of oesophageal cancer: technique description, case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Luisa Castilla

    2015-07-01

    Full Text Available Endoesophageal brachytherapy is a useful technique for the palliative treatment of dysphagia in advanced oesophageal cancer. This technique offers good results on dysphagia control and quality of life. We report the case of a patient treated with this technique presenting complete response to the dysphagia. We describe endoesophageal brachyterapy technique and we comment on the literature.

  7. Influence of radiographic techniques on the measurement of femoral anteversion angles and a conformation score of pelvic limbs in Labrador retrievers.

    Science.gov (United States)

    Mostafa, Ayman A; Cunningham, Devin P; Boudrieau, Randy J; Kowaleski, Michael P; Griffon, Dominique J

    2018-04-01

    To determine repeatability of and correlation between 2 radiographic measurements of femoral anteversion angles (FAA) and to determine their influence on a score derived from tibial plateau angle (TPA) and FAA to predict the risk of cranial cruciate ligament disease (CCLD). Prospective clinical study. Forty-eight Labrador retrievers with or without CCLD. FAA and CCLD scores were calculated for each limb from extended pelvic radiographs (t-FAA) or angled (a-FAA) projections of the femur by 3 investigators. One investigator repeated measurements twice. Data were analyzed for repeatability, correlation between t-FAA and a-FAA, and their influence on CCLD scores. FAA correlated most strongly with the distance between the femoral head and the femoral axis on mediolateral radiographs, a measurement with excellent repeatability. t-FAA and a-FAA correlated with each other (r > 0.79, P FAA were about 1° greater than a-FAA (P = .01). Intrainvestigator and interinvestigator repeatability of the CCLD score was fair when derived from t-FAA and good to excellent when derived from a-FAA. CCLD scores differed between radiographic techniques but led to different predictions in only 9 (10%) limbs, all with lower TPA and CCLD scores than the rest of the population. a-FAA correlated strongly with t-FAA and improved the repeatability of CCLD scores within and between investigators. A craniocaudal angled beam projection of the femur is a suitable alternative to a ventrodorsal pelvic radiograph when measuring FAA and may improve the repeatability and positive predictive value of CCLD scores. © 2018 The American College of Veterinary Surgeons.

  8. utilization of adsorption and/or liquid membranes techniques in treatment of some hazardous substances

    International Nuclear Information System (INIS)

    Hussin, L.M.S.

    2011-01-01

    environmental pollution, as a consequence of the industrialization process, is one of the major problems that has to be solved and controlled. The most important treatment processes for metals and dyes contaminated waste streams include chemical precipitation, membrane, filtration, ion exchange, carbon adsorption and coprecipitation/adsorption. However, all these techniques have their inherent advantages and limitations in applications. These processes usually need expensive facility and high maintenance cost. Therefore, there is a need for more economical alternative technologies for the treatment of metals and dyes contaminated waste streams. The aim of present work is to study the treatment of some hazardous substances such as heavy metals e.g. ( lead, cobalt and strontium) and dyes e.g. ( acid red 73, and acid blue 74 ) using either adsorption or liquid emulsion membrane techniques. The experimental part deals with the application of adsorption and liquid emulsion membrane techniques for removal of some hazardous substances such as metal ions ( lead, cobalt and strontium) and dyes (acid red 73 and acid blue 74). All the apparatus and techniques employed were described.

  9. TH-EF-BRB-04: 4π Dynamic Conformal Arc Therapy Dynamic Conformal Arc Therapy (DCAT) for SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, T; Long, T; Tian, Z.; Yan, Y; Jiang, S; Gu, X [UT Southwestern Medical Center, Dallas, TX (United States); Modiri, A; Sawant, A [University of Maryland in Baltimore, Baltimore, MD (United States)

    2016-06-15

    Purpose: To develop an efficient and effective trajectory optimization methodology for 4π dynamic conformal arc treatment (4π DCAT) with synchronized gantry and couch motion; and to investigate potential clinical benefits for stereotactic body radiation therapy (SBRT) to breast, lung, liver and spine tumors. Methods: The entire optimization framework for 4π DCAT inverse planning consists of two parts: 1) integer programming algorithm and 2) particle swarm optimization (PSO) algorithm. The integer programming is designed to find an optimal solution for arc delivery trajectory with both couch and gantry rotation, while PSO minimize a non-convex objective function based on the selected trajectory and dose-volume constraints. In this study, control point interaction is explicitly taken into account. Beam trajectory was modeled as a series of control points connected together to form a deliverable path. With linear treatment planning objectives, a mixed-integer program (MIP) was formulated. Under mild assumptions, the MIP is tractable. Assigning monitor units to control points along the path can be integrated into the model and done by PSO. The developed 4π DCAT inverse planning strategy is evaluated on SBRT cases and compared to clinically treated plans. Results: The resultant dose distribution of this technique was evaluated between 3D conformal treatment plan generated by Pinnacle treatment planning system and 4π DCAT on a lung SBRT patient case. Both plans share the same scale of MU, 3038 and 2822 correspondingly to 3D conformal plan and 4π DCAT. The mean doses for most of OARs were greatly reduced at 32% (cord), 70% (esophagus), 2.8% (lung) and 42.4% (stomach). Conclusion: Initial results in this study show the proposed 4π DCAT treatment technique can achieve better OAR sparing and lower MUs, which indicates that the developed technique is promising for high dose SBRT to reduce the risk of secondary cancer.

  10. Comparação entre os volumes pulmonares irradiados com técnica bidimensional e tridimensional conformada na radioterapia de pacientes com tumores de pulmão localmente avançados Comparison between irradiated lung volumes with two-dimensional and three-dimensional conformal radiotherapy techniques for locally advanced lung cancer

    Directory of Open Access Journals (Sweden)

    Heloisa de Andrade Carvalho

    2009-10-01

    Full Text Available OBJETIVO: Comparar e quantificar os volumes pulmonares irradiados utilizando planejamentos bidimensional (2D e tridimensional (3D conformado na radioterapia de tumores de pulmão. MATERIAIS E MÉTODOS: Em 27 pacientes portadores de câncer de pulmão foi feito planejamento 3D e outro correspondente em 2D. As doses prescritas variaram de 45 a 66 Gy. Foram avaliadas as doses no volume alvo planejado (PTV, volume tumoral macroscópico (GTV e pulmões (volume de pulmão que recebe 20 Gy ou 30 Gy - V20 e V30, respectivamente, e dose média. Os órgãos de risco adjacentes (medula espinhal, esôfago e coração receberam doses abaixo dos limites de tolerância. RESULTADOS: O GTV variou de 10,5 a 1.290,0 cm³ (média de 189,65 cm³. Nos planejamentos 2D foi utilizado, em média, um total de 59,33 campos, e nos planejamentos 3D, 75,65 campos. Em todas as situações analisadas houve significante (p OBJECTIVE: To compare and quantify irradiated lung volumes using two-dimensional (2D and three-dimensional (3D conformal planning for radiotherapy in the treatment of lung cancer. MATERIALS AND METHODS: 2D and 3D conformal radiotherapy plannings were performed for 27 patients with lung cancer. Prescribed doses ranged from 45 to 66 Gy. The analysis covered the doses to planning target volume (PTV, gross tumor volume (GTV and lungs (lung volume receiving 20 Gy or 30 Gy - V20 and V30, respectively, and mean dose. The doses to adjacent organs at risk (spinal cord, esophagus and heart were maintained below the tolerance limits. RESULTS: GTV ranged from 10.5 to 1,290.0 cm³ (mean, 189.65 cm³. On average, a total of 59.33 fields were utilized in the 2D planning and 75.65 fields in the 3D planning. Lung volumes were significantly preserved (P < 0.05 with the 3D conformal planning in all the evaluated cases, with about 15% decrease in the irradiated lung volumes. Lungs without tumor were most benefited from this technique. CONCLUSION: 3D radiotherapy allowed a better

  11. [Balloon osteoplasty as reduction technique in the treatment of tibial head fractures].

    Science.gov (United States)

    Freude, T; Kraus, T M; Sandmann, G H

    2015-10-01

    Tibial plateau fractures requiring surgery are severe injuries of the lower extremities. Depending on the fracture pattern, the age of the patient, the range of activity and the bone quality there is a broad variation in adequate treatment.  This article reports on an innovative treatment concept to address split depression fractures (Schatzker type II) and depression fractures (Schatzker type III) of the tibial head using the balloon osteoplasty technique for fracture reduction. Using the balloon technique achieves a precise and safe fracture reduction. This internal osteoplasty combines a minimal invasive percutaneous approach with a gently rise of the depressed area and the associated protection of the stratum regenerativum below the articular cartilage surface. This article lights up the surgical procedure using the balloon technique in tibia depression fractures. Using the balloon technique a precise and safe fracture reduction can be achieved. This internal osteoplasty combines a minimally invasive percutaneous approach with a gentle raising of the depressed area and the associated protection of the regenerative layer below the articular cartilage surface. Fracture reduction by use of a tamper results in high peak forces over small areas, whereas by using the balloon the forces are distributed over a larger area causing less secondary stress to the cartilage tissue. This less invasive approach might help to achieve a better long-term outcome with decreased secondary osteoarthritis due to the precise and chondroprotective reduction technique.

  12. Choice of a General Anesthesia Technique in the Surgical Treatment of Postinfarct Left Ventricular Aneurysms

    Directory of Open Access Journals (Sweden)

    N. A. Karpun

    2005-01-01

    Full Text Available Objective. To choose the optimum technique of general anesthesia in the surgical treatment of patients with postinfarct left ventricular aneurysms (PLVA.Materials and methods. Fifty-four patients operated on for PLVA were examined. They were divided into 4 groups according to the basic technique of general anesthesia: 1 intravenous anesthesia based on propofol and fentanyl; 2 inhalation sevoflurane anesthesia with fentanyl enhancement of the analgesic component; 3 inhalation isoflurane anesthesia with fentanyl enhancement of the analgesic component; 4 general anesthesia in combination with epidural blockade. Central hemodynamics was investigated by the thermodilution technique and the perioperative period was also studied.Results and discussion. None of the general anesthesia techniques affected the development of perioperative complications. However, with decreased myocardial reserves, high thoracic epidural anesthesia should be applied with caution as it causes a significant desympathization, which may lead to impairments of the autoregulatory mechanisms of coronary blood flow and aggravate existing contractile disorders. Intravenous and inhalation anesthesia techniques provide a fair hemodynamic stability at all stages of surgical treatment. Inhalation anesthesia has a number of advantages: less cost and the possibility of rapid activation of patients in the early postoperative period.

  13. Outcome of endodontic treatment of teeth filled using lateral condensation versus vertical compaction (Schilder's technique).

    Science.gov (United States)

    Aqrabawi, Jamal A

    2006-02-15

    The purpose of this prospective clinical and radiographic investigation was to assess the treatment results following endodontic therapy of teeth filled with lateral condensation versus teeth filled with vertical compaction of warm gutta-percha. A total of 290 patients were treated using the standardized step-back technique for canal preparation, which were filled with either lateral condensation or vertical compaction in one single session. Five years later, the treatment results were assessed clinically and radiographically and related to the type of the obturation technique using Chi-square analysis. Of the 340 teeth that were reexamined, 160 teeth were filled with lateral condensation, and 180 teeth were filled with vertical condensation. The results showed a significantly higher success rate for the vertical compaction versus the lateral condensation technique of teeth presented with preoperative periapical lesions P<0.04. Regardless of the preoperative periapical status of the teeth, no statistically significant difference was found between the two techniques. The overall success rate of both filling techniques was 80.3%.

  14. Priority of surgical treatment techniques of full cartilage defects of knee joint

    Directory of Open Access Journals (Sweden)

    Андрій Вікторович Літовченко

    2015-10-01

    Full Text Available Aim. Surgical treatment of chondromalacia of knee joint cartilage is an actual problem of the modern orthopedics because the means of conservative therapy can be realized at an initial stage only and almost exhausted at the further ones. Imperfections of palliative surgical techniques are the short-term clinical effect and pathogenetic baselessness because surgical procedure is not directed on reparation of cartilaginous tissue. For today there are a lot of transplantation techniques that are used for biological renewal of articular surface with formation of hyaline or at least hyaline-like cartilage. The deep forage of cartilage defect bottom to the medullary canal is a perspective and priority technique.Methods. The results of treatment of 61 patients with chondromalacia of knee joint of 3-4 degree according to R. Outerbridge are the base of the work. 20 patients of every group underwent microfracturization of cartilage defect bottom and subchondral forage of defect zone. 21 patients underwent the deep forage of defect zone of knee joint according to an offered technique.Result. The results of treatment with microfracturization, subchondral forage and deep forage of defect zone indicate the more strong clinical effect especially in the last clinical group where good and satisfactory results ratios in the term of observation 18 and 24 month remain stable.Conclusions. Deep forage of cartilage defects zone is the most adequate reparative technique of the surgical treatment of local knee joint cartilage defects. Owing to this procedure the number of cells of reparative chondrogenesis predecessors is realized

  15. Implementation of intensity-modulated conformational radiotherapy (IMRT) for the treatment of cervical cancers at the Alexis-Vautrin Centre; Implementation de la radiotherapie conformationnelle avec modulation d'intensite (RCMI) pour le traitement des cancers du col uterin au centre Alexis-Vautrin

    Energy Technology Data Exchange (ETDEWEB)

    Renard-Oldrini, S.; Brunaud, C.; Marchesi, V.; Tournier-Rangeard, L.; Peiffert, D. [Centre Alexis-Vautrin, 54 - Nancy (France)

    2010-10-15

    The authors discuss the comparison of the treatment plans of eleven patients treated either by conformational irradiation for seven of them, or by intensity-modulated conformational irradiation (IMRT) for four of them. The IMRT results in a good target volume coverage, can better protect the intestine than the conventional irradiation, and therefore is very promising, notably in terms of digestive toxicity. Short communication

  16. The effect of varying incubation times for hypotonic treatment of lymphocytes in dicentric assay technique

    International Nuclear Information System (INIS)

    Noraisyah Yusof; Noriah Jamal; Rahimah Abdul Rahim; Juliana Mahamad Napiah

    2010-01-01

    The International Atomic Energy Agency (IAEA) has recommended that incubation time for the hypotonic treatment of lymphocytes in dicentric assay technique to be between 15 to 20 minutes. Incubation time will effect the hypotonic treatment of lymphocytes and thus, the breakage of cytoplasmic membrane. The objective of this study is to examine the effect of varying incubation times for hypotonic treatment of lymphocytes in dicentric assay technique. In this study, we choose to use our standard protocol for dicentric assay technique. However, for the hypotonic treatment of lymphocytes, the incubation times were varied from 10, 15, 20, 25 and 30 minutes respectively. Lymphocytes were then fixed and stained with Giemsa. The cells were then analyzed for clear background that indicates good metaphases. We found that incubation time of 30 minutes gives the best metaphase images. This incubation time is longer than what has been recommended by the IAEA. This maybe explained by the fact that our country's climate is of higher humidity compared with the European countries. (author)

  17. Percutaneous treatment of insufficiency fractures. Principles, technique and review of literature

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Datir, Abhijit; D'Souza, Sharon L.; D'Souza, Logan S.; Gunda, Divya; Morelli, John; Johnson, Michael Brandon; Nabavizadeh, Nima

    2010-01-01

    Insufficiency fractures of the pelvis, sacrum, spine, and long bones are painful, debilitating, and are common consequences of osteoporosis. Conventional treatment for these fractures varies from conservative therapy to surgery with plate and screw fixation. The former fails to address the underlying problem of fracture and frequently does not alleviate symptoms, while the latter is invasive and not always possible in older populations with low bone density and numerous co-morbidities. Osseous augmentation with polymethylmethacrylate (PMMA) has been used for over two decades to treat fractures related to osteoporosis, but has not been commonly used to treat fractures outside of the vertebral bodies. Osseous augmentation with PMMA is an image-guided procedure and various techniques have been utilized to treat fracture in different locations. We describe various techniques for image-guided osseous augmentation and treatment of insufficiency fractures with bothPMMA and allograft bone for fractures of the pelvis including sacrum, acetabulum, pubic symphysis, pubic rami ilium; appendicular skeleton including distal radius, proximal femur, and vertebral body. We also describe the potential risks and complications associated with percutaneous treatment of insufficiency fractures and techniques to avoid the pitfalls of the various procedures. We will present the process for patient follow-up and data regarding the pre- and postprocedure pain response in patients undergoing treatment for pelvic insufficiency fractures. (orig.)

  18. Independent technique of verifying high-dose rate (HDR) brachytherapy treatment plans

    International Nuclear Information System (INIS)

    Saw, Cheng B.; Korb, Leroy J.; Darnell, Brenda; Krishna, K. V.; Ulewicz, Dennis

    1998-01-01

    Purpose: An independent technique for verifying high-dose rate (HDR) brachytherapy treatment plans has been formulated and validated clinically. Methods and Materials: In HDR brachytherapy, dwell times at respective dwell positions are computed, using an optimization algorithm in a HDR treatment-planning system to deliver a specified dose to many target points simultaneously. Because of the variability of dwell times, concerns have been expressed regarding the ability of the algorithm to compute the correct dose. To address this concern, a commercially available low-dose rate (LDR) algorithm was used to compute the doses at defined distances, based on the dwell times obtained from the HDR treatment plans. The percent deviation between doses computed using the HDR and LDR algorithms were reviewed for HDR procedures performed over the last year. Results: In this retrospective study, the difference between computed doses using the HDR and LDR algorithms was found to be within 5% for about 80% of the HDR procedures. All of the reviewed procedures have dose differences of less than 10%. Conclusion: An independent technique for verifying HDR brachytherapy treatment plans has been validated based on clinical data. Provided both systems are available, this technique is universal in its applications and not limited to either a particular implant applicator, implant site, or implant type

  19. Remediation of textile effluents by membrane based treatment techniques: a state of the art review.

    Science.gov (United States)

    Dasgupta, Jhilly; Sikder, Jaya; Chakraborty, Sudip; Curcio, Stefano; Drioli, Enrico

    2015-01-01

    The textile industries hold an important position in the global industrial arena because of their undeniable contributions to basic human needs satisfaction and to the world economy. These industries are however major consumers of water, dyes and other toxic chemicals. The effluents generated from each processing step comprise substantial quantities of unutilized resources. The effluents if discharged without prior treatment become potential sources of pollution due to their several deleterious effects on the environment. The treatment of heterogeneous textile effluents therefore demands the application of environmentally benign technology with appreciable quality water reclamation potential. These features can be observed in various innovative membrane based techniques. The present review paper thus elucidates the contributions of membrane technology towards textile effluent treatment and unexhausted raw materials recovery. The reuse possibilities of water recovered through membrane based techniques, such as ultrafiltration and nanofiltration in primary dye houses or auxiliary rinse vats have also been explored. Advantages and bottlenecks, such as membrane fouling associated with each of these techniques have also been highlighted. Additionally, several pragmatic models simulating transport mechanism across membranes have been documented. Finally, various accounts dealing with techno-economic evaluation of these membrane based textile wastewater treatment processes have been provided. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Conformation radiotherapy with eccentric multi-leaves, (1)

    International Nuclear Information System (INIS)

    Obata, Yasunori; Sakuma, Sadayuki.

    1986-01-01

    In order to extend the application of the conformation radiotherapy, the eccentric multi-leaves are equipped with the linear accelerator. The information of the position of the collimators and the dose distribution of the eccentric conformation radiotherapy are calculated by the improved algorism of the treatment planning system. In simple cases, the dose distributions for the distant region from the rotational center are measured and compared with the calculated values. Both distributions are well coincided with the error of about 5 % in the high dose region and 10 % in the low dose region. In eccentric conformation radiotherapy, it is difficult to deliver the planned dose to the lesion. The dose increases with the distance of the target area from the rotational center. And the measured value and the calculated value are well coincided with 1 % error. So after getting the dose ratio of the rotational center to the target area, the calculated dose can be delivered to the rotational center. The advantages of the eccentric conformation radiotherapy are a good coincidence of target area and treated area, a partial shielding and a hollow out technique without absorber. The limitation of the movement of the collimator from center is 5 cm at 1 m SCD. (author)

  1. Transcatheter closure of patent ductus arteriosus with special conformation

    International Nuclear Information System (INIS)

    Zhang Yigang; Li Shijie; Fu Qiang

    2009-01-01

    Objective: To discuss the technique of transcatheter closure for the treatment of patent ductus arteriosus (PDA) with special conformation so as to improve the technical success rate and clinical safety. Methods: Transcatheter closure was performed in 23 patients with PDA of special types by using different devices according to the angiocardiographic conformation and the clinical manifestation. The therapeutic results were evaluated by transthoracic color Doppler echocardiography at 24 hours, one, three and six months after the operation. Results: Different occluders were successfully implanted in all patients. PDA of special types was found in 23 patients, which included: (1) special conformation (n=12), consisting of small type (n=5), huge type (n=3), aneurismal type (n=2) and displayed on special exposure position (n=2), (2) accompanied by other malformations (n=2), containing dextroaortic arch (n=1) and dextrocardia (n=1), (3) associated with severe pulmonary hypertension (n=8) and (4) recanalization after surgery (n=1). Conclusion: For PDA with special conformation, therapeutic strategy should be individually formulated in order to smoothly bring the closure procedure to success. (authors)

  2. Prostate and seminal vesicle volume based consideration of prostate cancer patients for treatment with 3D-conformal or intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Reddy, Nandanuri M. S.; Nori, Dattatreyudu; Chang, Hyesook; Lange, Christopher S.; Ravi, Akkamma

    2010-01-01

    Purpose: The purpose of this article was to determine the suitability of the prostate and seminal vesicle volumes as factors to consider patients for treatment with image-guided 3D-conformal radiation therapy (3D-CRT) or intensity-modulated radiation therapy (IMRT), using common dosimetry parameters as comparison tools. Methods: Dosimetry of 3D and IMRT plans for 48 patients was compared. Volumes of prostate, SV, rectum, and bladder, and prescriptions were the same for both plans. For both 3D and IMRT plans, expansion margins to prostate+SV (CTV) and prostate were 0.5 cm posterior and superior and 1 cm in other dimensions to create PTV and CDPTV, respectively. Six-field 3D plans were prepared retrospectively. For 3D plans, an additional 0.5 cm margin was added to PTV and CDPTV. Prescription for both 3D and IMRT plans was the same: 45 Gy to CTV followed by a 36 Gy boost to prostate. Dosimetry parameters common to 3D and IMRT plans were used for comparison: Mean doses to prostate, CDPTV, SV, rectum, bladder, and femurs; percent volume of rectum and bladder receiving 30 (V30), 50 (V50), and 70 Gy (V70), dose to 30% of rectum and bladder, minimum and maximum point dose to CDPTV, and prescription dose covering 95% of CDPTV (D95). Results: When the data for all patients were combined, mean dose to prostate and CDPTV was higher with 3D than IMRT plans (P 0.2). On average, among all cases, the minimum point dose was less for 3D-CRT plans and the maximum point dose was greater for 3D-CRT than for IMRT (P 0.1). V30 was less (P 0.2), and V70 was more (P 0.2). Mean dose to femurs was more with 3D than IMRT plans (P 3 (39/48), respectively (P 3 , respectively, would be suitable for 3D-CRT. Patients with prostate and prostate+SV volumes >65 and 85 cm 3 , respectively, might get benefit from IMRT.

  3. Emergency treatment of exertional heatstroke and comparison of whole body cooling techniques.

    Science.gov (United States)

    Costrini, A

    1990-02-01

    This manuscript compares the whole body cooling techniques in the emergency treatment of heatstroke. Historically, the use of cold water immersion with skin massage has been quite successful in rapidly lowering body temperature and in avoiding severe complications or death. Recent studies have suggested alternative therapies, including the use of a warm air spray, the use of helicopter downdraft, and pharmacological agents. While evidence exists to support these methods, they have not been shown to reduce fatalities as effectively as ice water immersion. Although several cooling methods may have clinical use, all techniques rely on the prompt recognition of symptoms and immediate action in the field.

  4. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    Science.gov (United States)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-01-01

    Introduction Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. Methods A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. Results The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. Conclusion The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques. PMID:26229623

  5. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    International Nuclear Information System (INIS)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-01-01

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques

  6. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT).

    Science.gov (United States)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-12-01

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147-53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose-volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques.

  7. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    Energy Technology Data Exchange (ETDEWEB)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham [Andrew Love Cancer Centre, Geelong Hospital, Geelong, Victoria (Australia)

    2013-12-15

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques.

  8. The use of combined techniques: Scottish showers, hot bath and manual techniques in the treatment of migraine headache

    Directory of Open Access Journals (Sweden)

    Andrei-Cătălin Ionițe

    2017-12-01

    Full Text Available Migraines are caused by internal factors (out of which the most important are genetically and physiologically determined and the external ones, namely, the environment. The most common factor which triggers the migraines is the physiological one. According to some specialized studies, in most cases, it is assumed that migraines are caused by a neuro-vascular disorder. This statement works as a compromise solution for the two theories supported by specialists, which explain the occurrence of migraines: neural mechanisms theory and the theory of vascular origin. Starting from these two theories, we’ve used Scottish showers, hot baths (37oC followed by manual drainage of the venous sinuses. The Scottish showers determine the toning of the muscle capillaries. Immersion in warm water for 15 minutes determines vasodilation, along with muscle and mental relaxation. Drainage techniques of venous sinuses operate on the reciprocal tension membranes (RTM, restoring their mobility and improving neuro-vascular disorders. In this research, there were involved 3 subjects, who have taken part in the treatment sessions; they have been monitored and the resulting data has been recorded.

  9. Understanding modern magnets through conformal mapping

    International Nuclear Information System (INIS)

    Halbach, K.

    1989-10-01

    I want to show with the help of a number of examples that conformal mapping is a unique and enormously powerful tool for thinking about, and solving, problems. Usually one has to write down only a few equations, and sometimes none at all exclamation point When I started getting involved in work for which conformal mapping seemed to be a powerful tool, I did not think that I would ever be able to use that technique successfully because it seemed to require a nearly encyclopedic memory, an impression that was strengthened when I saw K. Kober's Dictionary of Conformal Representations. This attitude changed when I started to realize that beyond the basics of the theory of a function of a complex variable, I needed to know only about a handful of conformal maps and procedures. Consequently, my second goal for this talk is to show that in most cases conformal mapping functions can be obtained by formulating the underlying physics appropriately. This means particularly that encyclopedic knowledge of conformal maps is not necessary for successful use of conformal mapping techniques. To demonstrate these facts I have chosen examples from an area of physics/engineering in which I am active, namely accelerator physics. In order to do that successfully I start with a brief introduction into high energy charged particle storage ring technology, even though not all examples used in this paper to elucidate my points come directly from this particular field of accelerator technology

  10. Strategies and techniques to enhance constructed wetland performance for sustainable wastewater treatment.

    Science.gov (United States)

    Wu, Haiming; Fan, Jinlin; Zhang, Jian; Ngo, Huu Hao; Guo, Wenshan; Liang, Shuang; Hu, Zhen; Liu, Hai

    2015-10-01

    Constructed wetlands (CWs) have been used as an alternative to conventional technologies for wastewater treatment for more than five decades. Recently, the use of various modified CWs to improve treatment performance has also been reported in the literature. However, the available knowledge on various CW technologies considering the intensified and reliable removal of pollutants is still limited. Hence, this paper aims to provide an overview of the current development of CW strategies and techniques for enhanced wastewater treatment. Basic information on configurations and characteristics of different innovations was summarized. Then, overall treatment performance of those systems and their shortcomings were further discussed. Lastly, future perspectives were also identified for specialists to design more effective and sustainable CWs. This information is used to inspire some novel intensifying methodologies, and benefit the successful applications of potential CW technologies.

  11. Towards a standard protocol for antimony intralesional infiltration technique for cutaneous leishmaniasis treatment

    Directory of Open Access Journals (Sweden)

    Rosiana Estéfane da Silva

    Full Text Available BACKGROUND Despite its recognised toxicity, antimonial therapy continues to be the first-line drug for cutaneous leishmaniasis (CL treatment. Intralesional administration of meglumine antimoniate (MA represents an alternative that could reduce the systemic absorption of the drug and its side effects. OBJECTIVES This study aims to validate the standard operational procedure (SOP for the intralesional infiltration of MA for CL therapy as the first step before the assessment of efficacy and safety related to the procedure. METHODS The SOP was created based on 21 trials retrieved from the literature, direct monitoring of the procedure and consultation with experts. This script was submitted to a formal computer-aided inspection to identify readability, clarity, omission, redundancy and unnecessary information (content validation. For criterion and construct validations, the influence of critical condition changes (compliance with the instructions and professional experience on outcome conformity (saturation status achievement, tolerability (pain referred and safety (bleeding were assessed. FINDINGS The median procedure length was 12 minutes and in 72% of them, patients classified the pain as mild. The bleeding was also classified as mild in 96.6% of the procedures. Full compliance with the SOP was observed in 66% of infiltrations. Despite this, in 100% of the inspected procedures, lesion saturation was observed at the end of infiltration, which means that it tolerates some degree of modification in its execution (robustness without prejudice to the result. CONCLUSIONS The procedure is reproducible and can be used by professionals without previous training with high success and safety rates.

  12. Towards a standard protocol for antimony intralesional infiltration technique for cutaneous leishmaniasis treatment.

    Science.gov (United States)

    Silva, Rosiana Estéfane da; Carvalho, Janaína de Pina; Ramalho, Dario Brock; Senna, Maria Camilo Ribeiro De; Moreira, Hugo Silva Assis; Rabello, Ana; Cota, Erika; Cota, Gláucia

    2018-02-01

    BACKGROUND Despite its recognised toxicity, antimonial therapy continues to be the first-line drug for cutaneous leishmaniasis (CL) treatment. Intralesional administration of meglumine antimoniate (MA) represents an alternative that could reduce the systemic absorption of the drug and its side effects. OBJECTIVES This study aims to validate the standard operational procedure (SOP) for the intralesional infiltration of MA for CL therapy as the first step before the assessment of efficacy and safety related to the procedure. METHODS The SOP was created based on 21 trials retrieved from the literature, direct monitoring of the procedure and consultation with experts. This script was submitted to a formal computer-aided inspection to identify readability, clarity, omission, redundancy and unnecessary information (content validation). For criterion and construct validations, the influence of critical condition changes (compliance with the instructions and professional experience) on outcome conformity (saturation status achievement), tolerability (pain referred) and safety (bleeding) were assessed. FINDINGS The median procedure length was 12 minutes and in 72% of them, patients classified the pain as mild. The bleeding was also classified as mild in 96.6% of the procedures. Full compliance with the SOP was observed in 66% of infiltrations. Despite this, in 100% of the inspected procedures, lesion saturation was observed at the end of infiltration, which means that it tolerates some degree of modification in its execution (robustness) without prejudice to the result. CONCLUSIONS The procedure is reproducible and can be used by professionals without previous training with high success and safety rates.

  13. Dermal fillers for the treatment of tear trough deformity: A review of anatomy, treatment techniques, and their outcomes

    Directory of Open Access Journals (Sweden)

    Jaishree Sharad

    2012-01-01

    Full Text Available Tear trough deformity is a major concern in a lot of individuals seeking periorbital rejuvenation. A prominent tear trough deformity is characterised by a sunken appearance of the eye that results in the casting of a dark shadow over the lower eyelid, giving the patient a fatigued appearance despite adequate rest, and is refractory to attempts at cosmetic concealment. The tear trough deformity is a natural consequence of the anatomic attachments of the periorbital tissues. A variety of techniques have evolved to address this cosmetic issue. Traditional techniques relied on surgical excision of skin, muscle, and fat as well as chemical peels. Treatment is now tailored towards specific anatomic abnormalities and often employs multiple modalities including surgery, botulinum toxin, and replacement of volume. Various original research articles, text book publications and review articles were studied. Data specific to the historical aspect and anatomy of tear trough have been enumerated. Techniques of different authors were analysed and their results and complications have been summarised. The technique of the author has also been described here.

  14. Inversion theory and conformal mapping

    CERN Document Server

    Blair, David E

    2000-01-01

    It is rarely taught in an undergraduate or even graduate curriculum that the only conformal maps in Euclidean space of dimension greater than two are those generated by similarities and inversions in spheres. This is in stark contrast to the wealth of conformal maps in the plane. The principal aim of this text is to give a treatment of this paucity of conformal maps in higher dimensions. The exposition includes both an analytic proof in general dimension and a differential-geometric proof in dimension three. For completeness, enough complex analysis is developed to prove the abundance of conformal maps in the plane. In addition, the book develops inversion theory as a subject, along with the auxiliary theme of circle-preserving maps. A particular feature is the inclusion of a paper by Carath�odory with the remarkable result that any circle-preserving transformation is necessarily a M�bius transformation, not even the continuity of the transformation is assumed. The text is at the level of advanced undergr...

  15. Depression in Chinese men undergoing different assisted reproductive technique treatments: prevalence and risk factors.

    Science.gov (United States)

    Li, Li; Zhang, Yuanzhen; Zeng, Dan; Li, Fei; Cui, Dan

    2013-09-01

    To explore the prevalence and risk factors for depression in men undergoing different assisted reproductive technique (ART) treatments in Chinese population. This was a prospective study of 844 men undergoing ART treatments. All men were distributed to four groups, according to they received treatments. The treatments included IUI (intrauterine insemination), IVF(in vitro fertilization), ICSI(intra cytoplasmatic sperm injection) and TESA/PESA (percutaneous epididymal sperm aspiration/testicular sperm aspiration). Their symptoms of depression were measured with use of the Center for Epidemiologic Studies of Depression scale(CES-D). Data were collected about age, BMI, education, duration of marriage, duration of infertility, smoking, type of infertility, infertility causes, history of ejaculation failure, and financial burden of the treatment. We estimated the prevalence of depressive symptom in men undergoing different ART and used logistic regression models to identify risk factors for depression in different groups. The overall prevalence of depression was 13.3 % for men undergoing ART treatments: 14.5 % of IUI group, 12.4 % of IVF group, 19.2 % of ICSI group and 6.2 % of TESA/PESA group. Prevalence of depression among IUI group, IVF group and ICSI group were not significantly different. For IUI group, the factors were found to increase depression risk were treatment financial burden and duration of marriage, to decrease depression risk was age. For IVF group, the risk factors independently associated with depression were both male and female infertility, unexplained infertility, and history of ejaculation failure. In a sample of Chinese men undergoing ART treatments, the prevalence of depression was higher than other country. The risk factors for depression varied in different ART treatments groups. when routine screening to identify the sub-group of vulnerable men which need counselling before ART treatments, we should also consider which pattern of ART

  16. A Comparative Study of Two Techniques of Cryotherapy in the Treatment of Seborrheic Kreatosis

    Directory of Open Access Journals (Sweden)

    Osman Tuna

    2008-09-01

    Full Text Available Objective: Seborrheic keratosis is a benign epidermal tumour that is generally pigmented and develop from the proliferation of epidermal keratinocytes. In this study, two different techniques, spray or probe applications used cryotherapy during the treatment of seborrheic keratosis were compared in terms of efficiency and undesired effects. By this way, it is aimed to find the most suitable technique in seborrheic keratosis treatment. Method: Eighty lesions were included in the study with the diagnosis of seborrheic keratosis. These 80 lesions were divided randomly into two groups of 40; to one of which spray cryotherapy to the second cryotherapy with probe were applied. If clinical improvement were seen treatment was accepted as successful. The patiens were evaluated 2 and 4 months after the therapy for the comparison of two treatment. The patients in both groups scored their pain from 1 to 10 during the cryotherapy.Results: In the study, great success was achieved in the treatment of seborrheic keratosis by using different cryotherapy methods. All the patients in both groups were diagnosed with hipopigmentation. They were found to continue hipopigmentation in the second and fourth months. It was found that the intensity of the pain which those in the probe cryotherapy group suffered was significantly greater statistically.Conclusion: It was concluded that spray cryotherapy should be preferred since it was less painful and required less equipment than probe cryotherapy.

  17. Easy and effective technique of preventing incisor flaring during Forsus treatment

    Directory of Open Access Journals (Sweden)

    Siddharth Shashidhar Revankar

    2014-01-01

    Full Text Available Lower incisor flaring is often encountered during Forsus treatment. To prevent this, consolidating the entire mandibular arch by ligature wire and cinching back the mandibular archwire has been recommended. However, lower incisor flaring might still occur due to ligature breakage from friction of the push rods and also cinching back the mandibular archwire might not be possible in few cases due to anatomic limitations. The following article describes an innovative technique to prevent any chances of lower incisor flaring during Forsus treatment in cases where cinching the archwire is not possible due to anatomic limitations. This method is simple, inexpensive, less time consuming and comfortable for the patient.

  18. Analytic aspects of rational conformal field theories

    International Nuclear Information System (INIS)

    Kiritsis, E.B.; Lawrence Berkeley Lab., CA

    1990-01-01

    The problem of deriving linear differential equations for correlation functions of Rational Conformal Field Theories is considered. Techniques from the theory of fuchsian differential equations are used to show that knowledge of the central charge, dimensions of primary fields and fusion rules are enough to fix the differential equations for one- and two-point functions on the tours. Any other correlation function can be calculated along similar lines. The results settle the issue of 'exact solution' of rational conformal field theories. (orig.)

  19. Utilization of a photon transport code to investigate radiation therapy treatment planning quantities and techniques

    International Nuclear Information System (INIS)

    Palta, J.R.

    1981-01-01

    A versatile computer program MORSE, based on neutron and photon transport theory has been utilzed to investigate radiation therapy treatment planning quantities and techniques. A multi-energy group representation of transport equation provides a concise approach in utilizing Monte Carlo numerical techniques to multiple radiation therapy treatment planning problems. Central axis total and scattered dose distributions for homogeneous and inhomogeneous water phantoms are calculated and the correction factor for lung and bone inhomogeneities are also evaluated. Results show that Monte Carlo calculations based on multi-energy group tansport theory predict the depth dose distributions that are in good agreement with available experimental data. Central axis depth dose distributions for a bremsstrahlung spectrum from a linear accelerator is also calculated to exhibit the versatility of the computer program in handling multiple radiation therapy problems. A novel approach is undertaken to study the dosimetric properties of brachytherapy sources

  20. Constraint treatment techniques and parallel algorithms for multibody dynamic analysis. Ph.D. Thesis

    Science.gov (United States)

    Chiou, Jin-Chern

    1990-01-01

    Computational procedures for kinematic and dynamic analysis of three-dimensional multibody dynamic (MBD) systems are developed from the differential-algebraic equations (DAE's) viewpoint. Constraint violations during the time integration process are minimized and penalty constraint stabilization techniques and partitioning schemes are developed. The governing equations of motion, a two-stage staggered explicit-implicit numerical algorithm, are treated which takes advantage of a partitioned solution procedure. A robust and parallelizable integration algorithm is developed. This algorithm uses a two-stage staggered central difference algorithm to integrate the translational coordinates and the angular velocities. The angular orientations of bodies in MBD systems are then obtained by using an implicit algorithm via the kinematic relationship between Euler parameters and angular velocities. It is shown that the combination of the present solution procedures yields a computationally more accurate solution. To speed up the computational procedures, parallel implementation of the present constraint treatment techniques, the two-stage staggered explicit-implicit numerical algorithm was efficiently carried out. The DAE's and the constraint treatment techniques were transformed into arrowhead matrices to which Schur complement form was derived. By fully exploiting the sparse matrix structural analysis techniques, a parallel preconditioned conjugate gradient numerical algorithm is used to solve the systems equations written in Schur complement form. A software testbed was designed and implemented in both sequential and parallel computers. This testbed was used to demonstrate the robustness and efficiency of the constraint treatment techniques, the accuracy of the two-stage staggered explicit-implicit numerical algorithm, and the speed up of the Schur-complement-based parallel preconditioned conjugate gradient algorithm on a parallel computer.

  1. Treatment of High-Flow Vascular Malformations by Venous Embolization Aided by Flow Occlusion Techniques

    International Nuclear Information System (INIS)

    Jackson, James E.; Mansfield, Averil O.; Allison, David J.

    1996-01-01

    Purpose: Transvenous embolization techniques may be helpful as alternatives to the arterial route when treating high-flow vascular malformations. We present our experience using these techniques in four patients. Methods: In one patient the venous portion of the arteriovenous malformation (AVM) was punctured directly; in the other three patients it was catheterized via a retrograde venous approach. Flow occlusion techniques were utilized in all patients during embolization, which was performed with absolute alcohol or N-butyl-2-cyanoacrylate.Results: Excellent clinical and angiographic results were obtained, with obliteration of arteriovenous shunting in all patients. There were no complications.Conclusion: The embolization of certain AVMs using a venous approach is a safe and effective treatment

  2. Percutaneous Treatment of Intrahepatic Biliary Leak: A Modified Occlusion Balloon Technique

    Energy Technology Data Exchange (ETDEWEB)

    Nasser, Felipe; Rocha, Rafael Dahmer, E-mail: rafaeldrocha@gmail.com; Falsarella, Priscila Mina; Motta-Leal-Filho, Joaquim Maurício da; Azevedo, André Arantes; Valle, Leonardo Guedes Moreira; Cavalcante, Rafael Noronha; Garcia, Rodrigo Gobbo; Affonso, Breno Boueri; Galastri, Francisco Leonardo [Hospital Israelita Albert Einstein, Department of Interventional Radiology (Brazil)

    2016-05-15

    PurposeTo report a novel modified occlusion balloon technique to treat biliary leaks.MethodsA 22-year-old female patient underwent liver transplantation with biliary-enteric anastomosis. She developed thrombosis of the common hepatic artery and extensive ischemia in the left hepatic lobe. Resection of segments II and III was performed and a biliary-cutaneous leak originating at the resection plane was identified in the early postoperative period. Initial treatment with percutaneous transhepatic drainage was unsuccessful. Therefore, an angioplasty balloon was coaxially inserted within the biliary drain and positioned close to the leak.ResultsThe fistula output abruptly decreased after the procedure and stopped on the 7th day. At the 3-week follow-up, cholangiography revealed complete resolution of the leakage.ConclusionThis novel modified occlusion balloon technique was effective and safe. However, greater experience and more cases are necessary to validate the technique.

  3. Dam geology and basic treatment(2). Adit substitution technique and measures against landslide involved in excavation

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Kin' ichi [Kinki Geological Center, Co. Ltd., Kyoto, Japan (JP)

    1988-12-25

    This paper discusses the adit substitution technique which is a method for special treatment of dams and measures against landslide involved in excavation. The adit substitution technique consists of excavating an adit in the natural ground, excavating another adit which is in contact with the first adit and is at a level higher than the first adit, placing concrete from the upper adit to the lower adit to fill first adit completely with concrete, excavating a third adit, filling the second adit with concrete similarly, and proceeding with this process to construct a water barrier within the natural ground until the water barrier reaches the required height. The paper explains examples of this technique used on four dams. It also explains examples of measures against excavation-induced landslide adopted on three dams. 13 refs., 8 figs., 2 tabs.

  4. An indirect veneer technique for simple and esthetic treatment of anterior hypoplastic teeth

    Directory of Open Access Journals (Sweden)

    Amit Khatri

    2010-01-01

    Full Text Available This study describes a technique for treating anterior hypoplastic teeth using indirect nanocomposite veneer restoration. The prime advantage of an indirect veneer technique is that it provides an esthetic and conservative result. One of the most frequent reasons that patients seek dental care is discolored anterior teeth. Although treatment options such as removal of surface stains, bleaching, microabrasion or macroabrasion, veneering, and placement of porcelain crowns are available, conservative approach such as veneer preserves the natural tooth as much as possible. Full veneers are recommended for the restoration of localized defects or areas of intrinsic discoloration, which are caused by deeper internal stains or enamel defects. Indirectly fabricated veneers are much less sensitive compared to a operator′s technique and if multiple teeth are to be veneered, indirect veneers can be usually placed much more expeditiously. Indirect veneers last much longer than the direct veneers. Therefore, indirectly fabricated veneers are more advantageous than directly fabricated veneers in many cases.

  5. The efficacy of a modified general hip technique in the treatment of leg length discrepancies

    OpenAIRE

    2015-01-01

    M.Dip.Tech. Functional leg length discrepancies, as distinct from anatomical discrepancies, are often associated with sacroiliac joint dysfunction. This may result in back pain and discomfort. Chiropractors usually treat this condition using a side posture sacroiliac adjustment, but in some cases, an adjustment may not be indicated. This study aims to determine whether a Modified General Hip technique would be an acceptable alternative treatment. For this study, 30 patients who suffered fr...

  6. Pre-optimization of radiotherapy treatment planning: an artificial neural network classification aided technique

    International Nuclear Information System (INIS)

    Hosseini-Ashrafi, M.E.; Bagherebadian, H.; Yahaqi, E.

    1999-01-01

    A method has been developed which, by using the geometric information from treatment sample cases, selects from a given data set an initial treatment plan as a step for treatment plan optimization. The method uses an artificial neural network (ANN) classification technique to select a best matching plan from the 'optimized' ANN database. Separate back-propagation ANN classifiers were trained using 50, 60 and 77 examples for three groups of treatment case classes (up to 21 examples from each class were used). The performance of the classifiers in selecting the correct treatment class was tested using the leave-one-out method; the networks were optimized with respect their architecture. For the three groups used in this study, successful classification fractions of 0.83, 0.98 and 0.93 were achieved by the optimized ANN classifiers. The automated response of the ANN may be used to arrive at a pre-plan where many treatment parameters may be identified and therefore a significant reduction in the steps required to arrive at the optimum plan may be achieved. Treatment planning 'experience' and also results from lengthy calculations may be used for training the ANN. (author)

  7. Induced quantum conformal gravity

    International Nuclear Information System (INIS)

    Novozhilov, Y.V.; Vassilevich, D.V.

    1988-11-01

    Quantum gravity is considered as induced by matter degrees of freedom and related to the symmetry breakdown in the low energy region of a non-Abelian gauge theory of fundamental fields. An effective action for quantum conformal gravity is derived where both the gravitational constant and conformal kinetic term are positive. Relation with induced classical gravity is established. (author). 15 refs

  8. Thickenings and conformal gravity

    Science.gov (United States)

    Lebrun, Claude

    1991-07-01

    A twistor correspondence is given for complex conformal space-times with vanishing Bach and Eastwood-Dighton tensors; when the Weyl curvature is algebraically general, these equations are precisely the conformal version of Einstein's vacuum equations with cosmological constant. This gives a fully curved version of the linearized correspondence of Baston and Mason [B-M].

  9. Thickenings and conformal gravity

    Energy Technology Data Exchange (ETDEWEB)

    LeBrun, C. (State Univ. of New York, Stony Brook, NY (USA). Dept. of Mathematics)

    1991-07-01

    A twistor correspondence is given for complex conformal space-times with vanishing Bach and Eastwood-Dighton tensors; when the Weyl curvature is algebraically general, these equations are precisely the conformal version of Einstein's vacuum equations with cosmological constant. This gives a fully curved version of the linearized correspondence of Baston and Mason (B-M). (orig.).

  10. Thickenings and conformal gravity

    International Nuclear Information System (INIS)

    LeBrun, C.

    1991-01-01

    A twistor correspondence is given for complex conformal space-times with vanishing Bach and Eastwood-Dighton tensors; when the Weyl curvature is algebraically general, these equations are precisely the conformal version of Einstein's vacuum equations with cosmological constant. This gives a fully curved version of the linearized correspondence of Baston and Mason [B-M]. (orig.)

  11. Conformational stability of calreticulin

    DEFF Research Database (Denmark)

    Jørgensen, C.S.; Trandum, C.; Larsen, N.

    2005-01-01

    The conformational stability of calreticulin was investigated. Apparent unfolding temperatures (T-m) increased from 31 degrees C at pH 5 to 51 degrees C at pH 9, but electrophoretic analysis revealed that calreticulin oligomerized instead of unfolding. Structural analyses showed that the single C......-terminal a-helix was of major importance to the conformational stability of calreticulin....

  12. Prostate and seminal vesicle volume based consideration of prostate cancer patients for treatment with 3D-conformal or intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, Nandanuri M. S.; Nori, Dattatreyudu; Chang, Hyesook; Lange, Christopher S.; Ravi, Akkamma [Department of Radiation Oncology, New York Hospital Queens, Flushing, New York 11355 (United States); Department of Radiation Oncology, State University of New York Downstate Medical Center, Brooklyn, New York 11203 (United States); Department of Radiation Oncology, New York Hospital Queens, Flushing, New York 11355 (United States)

    2010-07-15

    Purpose: The purpose of this article was to determine the suitability of the prostate and seminal vesicle volumes as factors to consider patients for treatment with image-guided 3D-conformal radiation therapy (3D-CRT) or intensity-modulated radiation therapy (IMRT), using common dosimetry parameters as comparison tools. Methods: Dosimetry of 3D and IMRT plans for 48 patients was compared. Volumes of prostate, SV, rectum, and bladder, and prescriptions were the same for both plans. For both 3D and IMRT plans, expansion margins to prostate+SV (CTV) and prostate were 0.5 cm posterior and superior and 1 cm in other dimensions to create PTV and CDPTV, respectively. Six-field 3D plans were prepared retrospectively. For 3D plans, an additional 0.5 cm margin was added to PTV and CDPTV. Prescription for both 3D and IMRT plans was the same: 45 Gy to CTV followed by a 36 Gy boost to prostate. Dosimetry parameters common to 3D and IMRT plans were used for comparison: Mean doses to prostate, CDPTV, SV, rectum, bladder, and femurs; percent volume of rectum and bladder receiving 30 (V30), 50 (V50), and 70 Gy (V70), dose to 30% of rectum and bladder, minimum and maximum point dose to CDPTV, and prescription dose covering 95% of CDPTV (D95). Results: When the data for all patients were combined, mean dose to prostate and CDPTV was higher with 3D than IMRT plans (P<0.01). Mean D95 to CDPTV was the same for 3D and IMRT plans (P>0.2). On average, among all cases, the minimum point dose was less for 3D-CRT plans and the maximum point dose was greater for 3D-CRT than for IMRT (P<0.01). Mean dose to 30% rectum with 3D and IMRT plans was comparable (P>0.1). V30 was less (P<0.01), V50 was the same (P>0.2), and V70 was more (P<0.01) for rectum with 3D than IMRT plans. Mean dose to bladder was less with 3D than IMRT plans (P<0.01). V30 for bladder with 3D plans was less than that of IMRT plans (P<0.01). V50 and V70 for 3D plans were the same for 3D and IMRT plans (P>0.2). Mean dose to femurs

  13. Treatment of alumina refinery waste (red mud) through neutralization techniques: A review.

    Science.gov (United States)

    Rai, Suchita; Wasewar, K L; Agnihotri, A

    2017-06-01

    In the Bayer process of extraction of alumina from bauxite, the insoluble product generated after bauxite digestion with sodium hydroxide at elevated temperature and pressure is known as 'red mud' or 'bauxite residue'. This alumina refinery waste is highly alkaline in nature with a pH of 10.5-12.5 and is conventionally disposed of in mostly clay-lined land-based impoundments. The alkaline constituents in the red mud impose severe and alarming environmental problems, such as soil and air pollution. Keeping in view sustainable re-vegetation and residue management, neutralization/treatment of red mud using different techniques is the only alternative to make the bauxite residue environmentally benign. Hence, neutralization techniques, such as using mineral acids, acidic waste (pickling liquor waste), coal dust, superphosphate and gypsum as amenders, CO 2 , sintering with silicate material and seawater for treatment of red mud have been studied in detail. This paper is based upon and emphasizes the experimental work carried out for all the neutralization techniques along with a comprehensive review of each of the processes. The scope, applicability, limitations and feasibility of these processes have been compared exhaustively. Merits and demerits have been discussed using flow diagrams. All the techniques described are technically feasible, wherein findings obtained with seawater neutralization can be set as a benchmark for future work. Further studies should be focused on exploring the economical viability of these processes for better waste management and disposal of red mud.

  14. Can field-in-field technique replace wedge filter in radiotherapy treatment planning: a comparative analysis in various treatment sites

    International Nuclear Information System (INIS)

    Prabhakar, R.; Julka, P.K.; Rath, G.K.

    2008-01-01

    The aim of the study was to show whether field-in-field (FIF) technique can be used to replace wedge filter in radiation treatment planning. The study was performed in cases where wedges are commonly used in radiotherapy treatment planning. Thirty patients with different malignancies who received radiotherapy were studied. This includes patients with malignancies of brain, head and neck, breast, upper and lower abdomen. All the patients underwent computed tomography scanning and the datasets were transferred to the treatment planning system. Initially, wedge based planning was performed to achieve the best possible dose distribution inside the target volume with multileaf collimators (Plan1). Wedges were removed from a copy of the same plan and FIF plan was generated (Plan2). The two plans were then evaluated and compared for mean dose, maximum dose, median dose, doses to 2% (D 2 ) and 98% (D 9 8) of the target volume, volume receiving greater than 107% of the prescribed dose (V>107%), volume receiving less than 95% of the prescribed dose (V 2 , V>107% and CI for more of the sites with statistically significant reduction in monitor units. FIF results in better dose distribution in terms of homogeneity in most of the sites. It is feasible to replace wedge filter with FIF in radiotherapy treatment planning.

  15. Conformal invariance in supergravity

    International Nuclear Information System (INIS)

    Bergshoeff, E.A.

    1983-01-01

    In this thesis the author explains the role of conformal invariance in supergravity. He presents the complete structure of extended conformal supergravity for N <= 4. The outline of this work is as follows. In chapter 2 he briefly summarizes the essential properties of supersymmetry and supergravity and indicates the use of conformal invariance in supergravity. The idea that the introduction of additional symmetry transformations can make clear the structure of a field theory is not reserved to supergravity only. By means of some simple examples it is shown in chapter 3 how one can always introduce additional gauge transformations in a theory of massive vector fields. Moreover it is shown how the gauge invariant formulation sometimes explains the quantum mechanical properties of the theory. In chapter 4 the author defines the conformal transformations and summarizes their main properties. He explains how these conformal transformations can be used to analyse the structure of gravity. The supersymmetric extension of these results is discussed in chapter 5. Here he describes as an example how N=1 supergravity can be reformulated in a conformally-invariant way. He also shows that beyond N=1 the gauge fields of the superconformal symmetries do not constitute an off-shell field representation of extended conformal supergravity. Therefore, in chapter 6, a systematic method to construct the off-shell formulation of all extended conformal supergravity theories with N <= 4 is developed. As an example he uses this method to construct N=1 conformal supergravity. Finally, in chapter 7 N=4 conformal supergravity is discussed. (Auth.)

  16. Forward treatment planning techniques to reduce the normalization effect in Gamma Knife radiosurgery.

    Science.gov (United States)

    Cheng, Hao-Wen; Lo, Wei-Lun; Kuo, Chun-Yuan; Su, Yu-Kai; Tsai, Jo-Ting; Lin, Jia-Wei; Wang, Yu-Jen; Pan, David Hung-Chi

    2017-11-01

    In Gamma Knife forward treatment planning, normalization effect may be observed when multiple shots are used for treating large lesions. This effect can reduce the proportion of coverage of high-value isodose lines within targets. The aim of this study was to evaluate the performance of forward treatment planning techniques using the Leksell Gamma Knife for the normalization effect reduction. We adjusted the shot positions and weightings to optimize the dose distribution and reduce the overlap of high-value isodose lines from each shot, thereby mitigating the normalization effect during treatment planning. The new collimation system, Leksell Gamma Knife Perfexion, which contains eight movable sectors, provides an additional means to reduce the normalization effect by using composite shots. We propose different techniques in forward treatment planning that can reduce the normalization effect. Reducing the normalization effect increases the coverage proportion of higher isodose lines within targets, making the high-dose region within targets more uniform and increasing the mean dose to targets. Because of the increase in the mean dose to the target after reducing the normalization effect, we can set the prescribed marginal dose at a higher isodose level and reduce the maximum dose, thereby lowering the risk of complications. © 2017 Shuang Ho Hospital-Taipei Medical University. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  17. Different techniques recently used for the treatment of textile dyeing effluents: a review

    International Nuclear Information System (INIS)

    Altaf, A.; Noor, S.; Sharif, Q.M.; Najeebullah, M.

    2010-01-01

    Industrial textile processing comprises the operation of pretreatment dyeing printing and finishing. These production processes produce a substantial amount of chemical pollution. Textile finishing's wastewater, especially dye house effluent, contain different classes of organic dyes, chemicals and auxiliaries. They are colored and have extreme pH, COD and BOD values, and contain different salts, surfactants heavy metals and mineral oils. Therefore, dye bath effluents have to be treated before being discharge into the environment or municipal wastewater reservoir. This paper presents the review of different techniques currently used for the treatment of textile effluent, which are based on carbon adsorption, filtration, chemical precipitation, photo degradation, biodegradation and electrolytic chemical treatment. Membrane Technology has also been applied with the objective of recovering dyes and water. Biological processes could be adopted as a pretreatment decolorization step, combined with conventional treatment system (eg. coagulation flocculation, adsorption on activated carbon) to reduce the COD and BOD, an effective alternative for use by the textile dyeing industries. Electrochemical oxidation is an efficient process for the removal of colour and total organic carbon in reactive dyes textile wastewater. The ozonation is effective for decolorization of several dyes of different classes. Practical application of this process is feasible by treating industrial textile effluent after biological treatment. Processes using membranes technique, very interesting possibilities of separating hydrolyzed dyestuffs, dyeing auxiliaries and reuse treated wastewater in different finishing operation of textile industries. (author)

  18. [Application of molecular diagnostic techniques in precision medicine of personalized treatment for colorectal cancer].

    Science.gov (United States)

    Fu, Ji; Lin, Guole

    2016-01-01

    Precision medicine is to customize the treatment options for individual patient based on the personal genome information. Colorectal cancer (CRC) is one of the most common cancer worldwide. Molecular heterogeneity of CRC, which includes the MSI phenotype, hypermutation phenotype, and their relationship with clinical preferences, is believed to be one of the main factors responsible for the considerable variability in treatment response. The development of powerful next-generation sequencing (NGS) technologies allows us to further understand the biological behavior of colorectal cancer, and to analyze the prognosis and chemotherapeutic drug reactions by molecular diagnostic techniques, which can guide the clinical treatment. This paper will introduce the new findings in this field. Meanwhile we integrate the new progress of key pathways including EGFR, RAS, PI3K/AKT and VEGF, and the experience in selective patients through associated molecular diagnostic screening who gain better efficacy after target therapy. The technique for detecting circulating tumor DNA (ctDNA) is introduced here as well, which can identify patients with high risk for recurrence, and demonstrate the risk of chemotherapy resistance. Mechanism of tumor drug resistance may be revealed by dynamic observation of gene alteration during treatment.

  19. Comparison of the pain levels of computer-controlled and conventional anesthesia techniques in prosthodontic treatment

    Directory of Open Access Journals (Sweden)

    Murat Yenisey

    2009-10-01

    Full Text Available OBJECTIVE: The objective of this study was to compare the pain levels on opposite sides of the maxilla at needle insertion during delivery of local anesthetic solution and tooth preparation for both conventional and anterior middle superior alveolar (AMSA technique with the Wand computer-controlled local anesthesia application. MATERIAL AND METHODS: Pain scores of 16 patients were evaluated with a 5-point verbal rating scale (VRS and data were analyzed nonparametrically. Pain differences at needle insertion, during delivery of local anesthetic, and at tooth preparation, for conventional versus the Wand technique, were analyzed using the Mann-Whitney U test (p=0.01. RESULTS: The Wand technique had a lower pain level compared to conventional injection for needle insertion (p0.05. CONCLUSIONS: The AMSA technique using the Wand is recommended for prosthodontic treatment because it reduces pain during needle insertion and during delivery of local anaesthetic. However, these two techniques have the same pain levels for tooth preparation.

  20. Discussion of percutanous nephrostomy technique with prevention and treatment of complications

    International Nuclear Information System (INIS)

    Zhang Zefu; Liang Huiming; Zheng Chuansheng; Wu Hanpin; Zhou Guofeng

    2008-01-01

    Objective: To analyze the complications and treatment technique of percutaneous nephrostomy. Methods: 247 hydronephrosis eases treated with percutaneous nephrostomy guided by ultrosound and fluroseopy flora Januray 2007 to April 2008 were evaluated retrospectively and the causes of complications and suitable treatments were analyzed. Results: The successful rate of percutaneous nephrostomy in 247 hydronephrotic cases reached 100%. In all cases, 4 cases occurred with severe complications (1.6%) including 3 massive hemorrhage and 1 septic shock during the operation. The minor complications (25 cases, 10% ) were hematuria, urinary tract infection, local haematoma, perirenal haematoma, detachment of drainage tube with obstruction and exodus, internal double-J catheter displacement and obstruction, etc. Conclusion: The operative safety and treatment efficacy of percutaneous nephrostomy could be achieved through skillful management and comprehensive preoperative evaluation of the risk factors for the complications. (authors)

  1. Early response of local steroid injection versus mini incision technique in treatment of carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Awan, A.S.; Khan, A.; Afridi, S.A.; Khan, R.S.

    2015-01-01

    Carpal tunnel syndrome Carpal tunnel syndrome (CTS) is one of the commonest peripheral neuropathies which effects mainly middle aged women. Different techniques are being tried to decrease the post-operative pain in patients operated for CTS. The objective of this study was to compare effectiveness of local injection of steroid and mini incision technique in the treatment of carpal tunnel syndrome. Methods: This randomized control trial was conducted at department of Orthopedics and department of Neurosurgery, Ayub Teaching Hospital, Abbottabad from Aug 2011 to Feb 2013. A total of 116 patients of CTS were randomly allocated to either of the two groups. Fifty-eight Patient in Group A were subjected to local steroid injection and the same number of patient in Group B underwent mini incision technique. All patients of were advised to report to the OPD after one month to determine intervention effectiveness in terms of improvement in at least on