WorldWideScience

Sample records for conformal radiotherapy 3dcrt

  1. Comparison of 3DCRT,VMAT and IMRT techniques in metastatic vertebra radiotherapy: A phantom Study

    Directory of Open Access Journals (Sweden)

    Gedik Sonay

    2017-01-01

    Full Text Available Vertebra metastases can be seen during the prognosis of cancer patients. Treatment ways of the metastasis are radiotherapy, chemotherapy and surgery. Three-dimensional conformal therapy (3D-CRT is widely used in the treatment of vertebra metastases. Also, Intensity Modulated Radiotherapy (IMRT and Volumetric Arc Therapy (VMAT are used too. The aim of this study is to examine the advantages and disadvantages of the different radiotherapy techniques. In the aspect of this goal, it is studied with a randophantom in Uludag University Medicine Faculty, Radiation Oncology Department. By using a computerized tomography image of the phantom, one 3DCRT plan, two VMAT and three IMRT plans for servical vertebra and three different 3DCRT plans, two VMAT and two IMRT plans for lomber vertebra are calculated. To calculate 3DCRT plans, CMS XiO Treatment System is used and to calculate VMAT and IMRT plans Monaco Treatment Planning System is used in the department. The study concludes with the dosimetric comparison of the treatment plans in the spect of critical organ doses, homogeneity and conformity index. As a result of this study, all critical organ doses are suitable for QUANTEC Dose Limit Report and critical organ doses depend on the techniques which used in radiotherapy. According to homogeneity and conformity indices, VMAT and IMRT plans are better than one in 3DCRT plans in servical and lomber vertebra radiotherapy plans.

  2. Single-arc volumetric-modulated arc therapy (sVMAT) as adjuvant treatment for gastric cancer: Dosimetric comparisons with three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT)

    International Nuclear Information System (INIS)

    Wang, Xin; Li, Guangjun; Zhang, Yingjie; Bai, Sen; Xu, Feng; Wei, Yuquan; Gong, Youling

    2013-01-01

    To compare the dosimetric differences between the single-arc volumetric-modulated arc therapy (sVMAT), 3-dimensional conformal radiotherapy (3D-CRT), and intensity-modulated radiotherapy (IMRT) techniques in treatment planning for gastric cancer as adjuvant radiotherapy. Twelve patients were retrospectively analyzed. In each patient's case, the parameters were compared based on the dose-volume histogram (DVH) of the sVMAT, 3D-CRT, and IMRT plans, respectively. Three techniques showed similar target dose coverage. The maximum and mean doses of the target were significantly higher in the sVMAT plans than that in 3D-CRT plans and in the 3D-CRT/IMRT plans, respectively, but these differences were clinically acceptable. The IMRT and sVMAT plans successfully achieved better target dose conformity, reduced the V 20/30 , and mean dose of the left kidney, as well as the V 20/30 of the liver, compared with the 3D-CRT plans. And the sVMAT technique reduced the V 20 of the liver much significantly. Although the maximum dose of the spinal cord were much higher in the IMRT and sVMAT plans, respectively (mean 36.4 vs 39.5 and 40.6 Gy), these data were still under the constraints. Not much difference was found in the analysis of the parameters of the right kidney, intestine, and heart. The IMRT and sVMAT plans achieved similar dose distribution to the target, but superior to the 3D-CRT plans, in adjuvant radiotherapy for gastric cancer. The sVMAT technique improved the dose sparings of the left kidney and liver, compared with the 3D-CRT technique, but showed few dosimetric advantages over the IMRT technique. Studies are warranted to evaluate the clinical benefits of the VMAT treatment for patients with gastric cancer after surgery in the future

  3. Chest wall desmoid tumours treated with definitive radiotherapy: a plan comparison of 3D conformal radiotherapy, intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy

    International Nuclear Information System (INIS)

    Liu, Jia; Ng, Diana; Lee, James; Stalley, Paul; Hong, Angela

    2016-01-01

    Definitive radiotherapy is often used for chest wall desmoid tumours due to size or anatomical location. The delivery of radiotherapy is challenging due to the large size and constraints of normal surrounding structures. We compared the dosimetry of 3D conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc radiotherapy (VMAT) to evaluate the best treatment option. Ten consecutive patients with inoperable chest wall desmoid tumours (PTV range 416–4549 cm 3 ) were selected. For each patient, 3DCRT, IMRT and VMAT plans were generated and the Conformity Index (CI), organ at risk (OAR) doses and monitor unit (MU) were evaluated. The Wilcoxon signed-rank test was used to compare dose delivered to both target and OARs. The mean number of fields for 3DCRT and IMRT were 6.3 ± 2.1, 7.2 ± 1.8. The mean number of arcs for VMAT was 3.7 ± 1.1. The mean conformity index of VMAT (0.98 ± 0.14) was similar to that of IMRT (1.03 ± 0.13), both of which were significantly better than 3DCRT (1.35 ± 0.20; p = 0.005). The mean dose to lung was significantly higher for 3DCRT (11.9Gy ± 7.9) compared to IMRT (9.4Gy ± 5.4, p = 0.014) and VMAT (8.9Gy ± 4.5, p = 0.017). For the 3 females, the low dose regions in the ipsilateral breast for VMAT were generally less with VMAT. IMRT plans required 1427 ± 532 MU per fraction which was almost 4-fold higher than 3DCRT (313 ± 112, P = 0.005). Compared to IMRT, VMAT plans required 60 % less MU (570 ± 285, P = 0.005). For inoperable chest wall desmoid tumours, VMAT delivered equivalent target coverage when compared to IMRT but required 60 % less MU. Both VMAT and IMRT were superior to 3DCRT in terms of better PTV coverage and sparing of lung tissue

  4. Conformation radiotherapy and conformal radiotherapy

    International Nuclear Information System (INIS)

    Morita, Kozo

    1999-01-01

    In order to coincide the high dose region to the target volume, the 'Conformation Radiotherapy Technique' using the multileaf collimator and the device for 'hollow-out technique' was developed by Prof. S. Takahashi in 1960. This technique can be classified a type of 2D-dynamic conformal RT techniques. By the clinical application of this technique, the late complications of the lens, the intestine and the urinary bladder after radiotherapy for the maxillary cancer and the cervical cancer decreased. Since 1980's the exact position and shape of the tumor and the surrounding normal tissues can be easily obtained by the tremendous development of the CT/MRI imaging technique. As a result, various kinds of new conformal techniques such as the 3D-CRT, the dose intensity modulation, the tomotherapy have been developed since the beginning of 1990'. Several 'dose escalation study with 2D-/3D conformal RT' is now under way to improve the treatment results. (author)

  5. Is IMRT Superior or Inferior to 3DCRT in Radiotherapy for NSCLC? A Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Xingsheng Hu

    Full Text Available There are no adequate data to determine whether intensity-modulated radiotherapy (IMRT is superior to three-dimensional conformal radiotherapy (3DCRT in the treatment of non-small cell lung cancer (NSCLC. This meta-analysis was conducted to compare the clinical outcomes of IMRT and 3DCRT in the treatment of NSCLC.No exclusions were made based on types of study design. We performed a literature search in PubMed, EMBASE and the Cochrane library databases from their inceptions to April 30, 2015. The overall survival (OS and relative risk (RR of radiation pneumonitis and radiation oesophagitis were evaluated. Two authors independently assessed the methodological quality and extracted data. Publication bias was evaluated by funnel plot using Egger's test results.From the literature search, 10 retrospective studies were collected, and of those, 5 (12,896 patients were selected for OS analysis, 4 (981 patients were selected for radiation pneumonitis analysis, and 4 (1339 patients were selected for radiation oesophagitis analysis. Cox multivariate proportional hazards models revealed that 3DCRT and IMRT had similar OS (HR = 0.96, P = 0.477 but that IMRT reduced the incidence of grade 2 radiation pneumonitis (RR = 0.74, P = 0.009 and increased the incidence of grade 3 radiation oesophagitis (RR = 2.47, P = 0.000.OS of IMRT for NSCLC is not inferior to that of 3DCRT, but IMRT significantly reduces the risk of radiation pneumonitis and increases the risk of radiation oesophagitis compared to 3DCRT.

  6. Could 3-D conformal radiotherapy improve the overall survival for non-small cell lung cancer?

    International Nuclear Information System (INIS)

    Giraud, P.; Helfre, S.; Lavole, A.; Rosenwald, J.C.; Cosset, J.M.

    2002-01-01

    The conformal radiotherapy approach, three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT), is based on modern imaging modalities, efficient 3-D treatment planning systems, sophisticated immobilization devices and demanding quality assurance and treatment verification. The main goal of conformal radiotherapy is to ensure a high dose distribution tailored to the limits of the target volume while reducing exposure of healthy tissues. These techniques would then allow a further dose escalation increasing local control and survival. Non-small cell lung cancer (NSCLC) is one of the most difficult malignant tumors to be treated. It combines geometrical difficulties due to respiratory motion, and number of low tolerance neighboring organs, and dosimetric difficulties because of the presence of huge inhomogeneities. This localization is an attractive and ambitious example for the evaluation of new techniques. However, the published clinical reports in the last years described very heterogeneous techniques and, in the absence of prospective randomized trials, it is somewhat difficult at present to evaluate the real benefits drawn from those conformal radiotherapy techniques. After reviewing the rationale for 3DCRT for NSCLC, this paper will describe the main studies of 3DCRT, in order to evaluate its impact on lung cancer treatment Then the current state-of-the-art of IMRT and the last technical and therapeutic innovations in NSCL will be discussed. (authors)

  7. Evaluations of secondary cancer risk in spine radiotherapy using 3DCRT, IMRT, and VMAT: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Rehman, Jalil ur, E-mail: jalil_khanphy@yahoo.com [Department of Physics, The Islamia University of Bahawalpur, Bahawalpur (Pakistan); Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX (United States); Tailor, Ramesh C. [Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX (United States); Isa, Muhammad [Department of Physics, The Islamia University of Bahawalpur, Bahawalpur (Pakistan); Princess Margaret Cancer Center, University Health Network, Toronto, Ontario (Canada); Afzal, Muhammad [Department of Physics, The Islamia University of Bahawalpur, Bahawalpur (Pakistan); Chow, James [Princess Margaret Cancer Center, University Health Network, Toronto, Ontario (Canada); Ibbott, Geoffrey S. [Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-04-01

    This study evaluated the secondary cancer risk from volumetric-modulated arc therapy (VMAT) for spine radiotherapy compared with intensity-modulated radiotherapy (IMRT) and 3-dimensional conformal radiotherapy (3DCRT). Computed tomography images of an Radiological Physics Center spine anthropomorphic phantom were exported to a treatment planning system (Pinnacle{sup 3}, version 9.4). Radiation treatment plans for spine were prepared using VMAT (dual-arc), 7-field IMRT (beam angles: 110°, 130°, 150°, 180°, 210°, 230°, and 250°), and 4-field 3DCRT technique. The mean and maximum doses, dose-volume histograms, and volumes receiving more than 2 and 4 Gy to organs at risk (OARs) were calculated and compared. The lifetime risk for secondary cancers was estimated according to the National Cancer Registry Programme Report 116. VMAT delivered the lowest maximum dose to the esophagus (4.03 Gy), bone (8.11 Gy), heart (2.11 Gy), spinal cord (6.45 Gy), and whole lung (5.66 Gy) as compared with other techniques (IMRT and 3DCRT). The volumes of OAR (esophagus) receiving more than 4 Gy were 0% for VMAT, 27.06% for IMRT, and up to 32.35% for 3DCRT. The estimated risk for secondary cancer in the respective OAR is considerably lower in VMAT compared with other techniques. The results of maximum doses and volumes of OARs suggest that the risk of secondary cancer induction for the spine in VMAT is lower than IMRT and 3DCRT, whereas VMAT has the best target coverage compared with the other techniques.

  8. Head and neck cancers: clinical benefits of three-dimensional conformal radiotherapy and of intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Giraud, P.; Jaulerry, C.; Brunin, F.; Zefkili, S.; Helfre, S.; Chauvet, I.; Rosenwald, J.C.; Cosset, J.M.

    2002-01-01

    The conformal radiotherapy approach, three-dimensional conformal radiotherapy (3DCRT) or intensity-modulated radiotherapy (IMRT), is based on modern imaging modalities, efficient 3-D treatment planning systems, sophisticated immobilization systems and rigorous quality assurance and treatment verification. The central objective of conformal radiotherapy is to ensure a high dose distribution tailored to the limits of the target volume while reducing exposure of normal tissues. These techniques would then allow further tumor dose escalation. Head-and-neck tumors are some of the most attractive localizations to test conformal radiotherapy. They combine ballistic difficulties due to particularly complex shapes (nasopharynx, ethmoid) and problems due to the number and low tolerance of neighbouring organs like parotids, eyes, brainstem and spinal cord. The therapeutic irradiation of head-and-neck tumors thus remains a challenge for the radiation oncologist. Conformal radiotherapy does have a significant potential for improving local control and reducing toxicity when compared to standard radiotherapy. However, in the absence of prospective randomized trials, it is somewhat difficult at present to evaluate the real benefits drawn from 3DCRT and IMRT. The published clinical reports on the use of conformal radiotherapy are essentially dealing with dosimetric comparisons on relatively small numbers of patients. Recently, a few publications have emphasized the clinical experience several precursor teams with a suitable follow-up. This paper describes the current state-of-the-art of 3DCRT and IMRT in order to evaluate the impact of these techniques on head-and-neck cancers irradiation. (authors)

  9. Pelvic Ewing sarcomas. Three-dimensional conformal vs. intensity-modulated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mounessi, F.S.; Lehrich, P.; Haverkamp, U.; Eich, H.T. [Muenster Univ. (Germany). Dept. of Radiation Oncology; Willich, N. [Muenster Univ. (Germany). Dept. of Radiation Oncology; Universitaetsklinikum Muenster (Germany). RiSK - Registry for the Evaluation of Late Side Effects after Radiotherapy in Childhood and Adolescence; Boelling, T. [Center for Radiation Oncology, Osnabrueck (Germany)

    2013-04-15

    The goal of the present work was to assess the potential advantage of intensity-modulated radiotherapy (IMRT) over three-dimensional conformal radiotherapy (3D-CRT) planning in pelvic Ewing's sarcoma. A total of 8 patients with Ewing sarcoma of the pelvis undergoing radiotherapy were analyzed. Plans for 3D-CRT and IMRT were calculated for each patient. Dose coverage of the planning target volume (PTV), conformity and homogeneity indices, as well as further parameters were evaluated. Results The average dose coverage values for PTV were comparable in 3D-CRT and IMRT plans. Both techniques had a PTV coverage of V{sub 95} > 98 % in all patients. Whereas the IMRT plans achieved a higher conformity index compared to the 3D-CRT plans (conformity index 0.79 {+-} 0.12 vs. 0.54 {+-} 0.19, p = 0.012), the dose distribution across the target volumes was less homogeneous with IMRT planning than with 3D-CRT planning. This difference was statistically significant (homogeneity index 0.11 {+-} 0.03 vs. 0.07 {+-} 0.0, p = 0.035). For the bowel, D{sub mean} and D{sub 1%}, as well as V{sub 2} to V{sub 60} were reduced in IMRT plans. For the bladder and the rectum, there was no significant difference in D{sub mean}. However, the percentages of volumes receiving at least doses of 30, 40, 45, and 50 Gy (V{sub 30} to V{sub 50}) were lower for the rectum in IMRT plans. The volume of normal tissue receiving at least 2 Gy (V{sub 2}) was significantly higher in IMRT plans compared with 3D-CRT, whereas at high dose levels (V{sub 30}) it was significantly lower. Compared to 3D-CRT, IMRT showed significantly better results regarding dose conformity (p = 0.012) and bowel sparing at dose levels above 30 Gy (p = 0.012). Thus, dose escalation in the radiotherapy of pelvic Ewing's sarcoma can be more easily achieved using IMRT. (orig.)

  10. Estimating the costs of intensity-modulated and 3-dimensional conformal radiotherapy in Ontario.

    Science.gov (United States)

    Yong, J H E; McGowan, T; Redmond-Misner, R; Beca, J; Warde, P; Gutierrez, E; Hoch, J S

    2016-06-01

    Radiotherapy is a common treatment for many cancers, but up-to-date estimates of the costs of radiotherapy are lacking. In the present study, we estimated the unit costs of intensity-modulated radiotherapy (imrt) and 3-dimensional conformal radiotherapy (3D-crt) in Ontario. An activity-based costing model was developed to estimate the costs of imrt and 3D-crt in prostate cancer. It included the costs of equipment, staff, and supporting infrastructure. The framework was subsequently adapted to estimate the costs of radiotherapy in breast cancer and head-and-neck cancer. We also tested various scenarios by varying the program maturity and the use of volumetric modulated arc therapy (vmat) alongside imrt. From the perspective of the health care system, treating prostate cancer with imrt and 3D-crt respectively cost $12,834 and $12,453 per patient. The cost of radiotherapy ranged from $5,270 to $14,155 and was sensitive to analytic perspective, radiation technique, and disease site. Cases of head-and-neck cancer were the most costly, being driven by treatment complexity and fractions per treatment. Although imrt was more costly than 3D-crt, its cost will likely decline over time as programs mature and vmat is incorporated. Our costing model can be modified to estimate the costs of 3D-crt and imrt for various disease sites and settings. The results demonstrate the important role of capital costs in studies of radiotherapy cost from a health system perspective, which our model can accommodate. In addition, our study established the need for future analyses of imrt cost to consider how vmat affects time consumption.

  11. Parotid gland-sparing 3-dimensional conformal radiotherapy results in less severe dry mouth in nasopharyngeal cancer patients: A dosimetric and clinical comparison with conventional radiotherapy

    International Nuclear Information System (INIS)

    Jen, Y.-M.; Shih Rompin; Lin, Y.-S.; Su, W.-F.; Ku, C.-H.; Chang, C.-S.; Shueng, P.-W.; Hwang, J.-M.; Liu, D.-W.; Chao, H.-L.; Lin, H.-Y.; Chang, L.-P.; Shum, W.-Y.; Lin, C.-S.

    2005-01-01

    Background and purpose: This study examined the efficacy of parotid gland sparing of three-dimensional conformal radiotherapy (3DCRT) compared with conventional radiotherapy for NPC patients. Both the dose given to the parotids and clinical assessment of dry mouth were conducted. Materials and methods: Dry mouth was assessed for 108 patients treated with conventional technique and 72 treated with 3DCRT. Dose analysis was performed in 48 patients of the 3DCRT group. A dose of 70 Gy was given to the midplane in conventional radiotherapy and to 90% isodose volume in 3DCRT. Prognostic factors affecting the severity of dry mouth were analyzed using Generalized Estimating Equation (GEE). Results: In the 3DCRT group about 50% of the patients' parotid glands received less than 25 Gy. Parallel analysis of dry mouth shows a significant decrease in the incidence of severe xerostomia after 3DCRT. The proportion of patients without dry mouth was also significantly higher in the 3DCRT group than the conventional group at 1-3 years after completion of radiotherapy. Although 3DCRT delivered a higher dose to the tumor, it spared the parotid gland significantly better than the conventional treatment. Late toxicities were mostly similar between the 2 groups while local control in T4 patients and survival were improved for 3DCRT. Conclusion: Dosimetrically and clinically 3DCRT is better than conventional technique regarding parotid gland protection

  12. Can advanced new radiation therapy technologies improve outcome of high grade glioma (HGG) patients? analysis of 3D-conformal radiotherapy (3DCRT) versus volumetric-modulated arc therapy (VMAT) in patients treated with surgery, concomitant and adjuvant chemo-radiotherapy

    International Nuclear Information System (INIS)

    Navarria, Pierina; Pessina, Federico; Cozzi, Luca; Ascolese, Anna Maria; Lobefalo, Francesca; Stravato, Antonella; D’Agostino, Giuseppe; Franzese, Ciro; Caroli, Manuela; Bello, Lorenzo; Scorsetti, Marta

    2016-01-01

    To assess the impact of volumetric-modulated arc therapy (VMAT) compared with 3D-conformal radiotherapy (3DCRT) in patients with newly diagnosed high grade glioma in terms of toxicity, progression free survival (PFS) and overall survival (OS). From March 2004 to October 2014, 341 patients underwent surgery followed by concomitant and adjuvant chemo-radiotherapy. From 2003 to 2010, 167 patients were treated using 3DCRT; starting from 2011, 174 patients underwent VMAT. The quantitative evaluation of the treatment plans was performed by means of standard dose volume histogram analysis. Response was recorded using the Response Assessment in Neuro-Oncology (RANO) criteria and toxicities graded according to Common Terminology Criteria for Adverse Event version 4.0. Both techniques achieved an adequate dose conformity to the target. The median follow up time was 1.3 years; at the last observation 76 patients (23.4 %) were alive and 249 (76.6 %) dead (16 patients were lot to follow-up). For patients who underwent 3DCRT, the median PFS was 0.99 ± 0.07 years (CI95: 0.9–1.1 years); the 1 and 3 years PFS were, 49.6 ± 4 and 19.1 ± 3.1 %. This shall be compared, respectively, to 1.29 ± 0.13 years (CI95: 1.01–1.5 years), 60.8 ± 3.8, and 29.7 ± 4.6 % for patients who underwent VMAT (p = 0.02). The median OS for 3DCRT patients was 1.21 ± 0.09 years (CI95:1.03–1.3 years); 1 and 5 year OS was, 63.3 ± 3.8 and 21.5 ± 3.3 %. The corresponding results for 3DRCT patients were 1.56 ± 0.09 years (CI95:1.37–1.74 years), 73.4 ± 3.5, 30 ± 4.6 % respectively (p < 0.01). In both groups, prognostic factors conditioning PFS and OS were age, gender, KPS, histology and extent of resection (EOR). VMAT resulted superior to 3DCRT in terms of dosimetric findings and clinical results

  13. Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT.

    Science.gov (United States)

    Murthy, Kk; Shukeili, Ka; Kumar, Ss; Davis, Ca; Chandran, Rr; Namrata, S

    2010-01-01

    To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over 3D-conformal radiotherapy (3D-CRT) planning in postoperative adjuvant radiotherapy for patients with gastric carcinoma. In a retrospective study, for plan comparison, dose distribution was recalculated in 15 patients treated with 3D-CRT on the contoured structures of same CT images using an IMRT technique. 3D-conformal plans with three fields and four-fields were compared with seven-field dynamic IMRT plans. The different plans were compared by analyzing the dose coverage of planning target volume using TV(95), D(mean), uniformity index, conformity index and homogeneity index parameters. To assess critical organ sparing, D(mean), D(max), dose to one-third and two-third volumes of the OARs and percentage of volumes receiving more than their tolerance doses were compared. The average dose coverage values of PTV with 3F-CRT and 4F-CRT plans were comparable, where as IMRT plans achieved better target coverage(p3D-CRT plans. The doses to the liver and bowel reduced significantly (p3D-CRT plans. For all OARs the percentage of volumes receiving more than their tolerance doses were reduced with the IMRT plans. This study showed that a better target coverage and significant dose reduction to OARs could be achieved with the IMRT plans. The IMRT can be preferred with caution for organ motion. The authors are currently studying organ motion in the upper abdomen to use IMRT for patient treatment.

  14. Intensity-modulated radiotherapy vs. parotid-sparing 3D conformal radiotherapy. Effect on outcome and toxicity in locally advanced head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lambrecht, M.; Nevens, D.; Nuyts, S. [University Hospitals Leuven (Belgium). Dept. of Radiation Oncology

    2013-03-15

    Background and purpose: Intensity-modulated radiotherapy (IMRT) has rapidly become standard of care in the management of locally advanced head and neck squamous cell carcinoma (HNSCC). In this study, our aim was to retrospectively investigate the effect of the introducing IMRT on outcome and treatment-related toxicity compared to parotid-sparing 3D conformal radiotherapy (3DCRT). Material and methods: A total of 245 patients with stage III and IV HNSCC treated with primary radiotherapy between January 2003 and December 2010 were included in this analysis: 135 patients were treated with 3DCRT, 110 patients with IMRT. Groups were compared for acute and late toxicity, locoregional control (LRC), and overall survival (OS). Oncologic outcomes were estimated using Kaplan-Meier analysis and compared using a log-rank test. Acute toxicity was analyzed according to the Common Terminology Criteria for Adverse Events v3.0 and late toxicity was scored using the RTOG/EORTC late toxicity scoring system. Results: Median follow-up was 35 months in the IMRT group and 68 months in the 3DCRT group. No significant differences were found in 3-year LRC and OS rates between the IMRT group and 3DCRT group. Significantly less acute mucositis {>=} grade 3 was observed in the IMRT group (32% vs. 44%, p = 0.03). There was significantly less late xerostomia {>=} grade 2 in the IMRT group than in the 3DCRT group (23% vs. 68%, p < 0.001). After 24 months, there was less dysphagia {>=} grade 2 in the IMRT group although differences failed to reach statistical significance. Conclusion: The introduction of IMRT in the radiotherapeutic management of locally advanced head and neck cancer significantly improved late toxicity without compromising tumor control compared to a parotid-sparing 3D conformal radiotherapy technique. (orig.)

  15. Anal wall sparing effect of an endorectal balloon in 3D conformal and intensity-modulated prostate radiotherapy.

    NARCIS (Netherlands)

    Smeenk, R.J.; Lin, E.N.J.T. van; Kollenburg, P. van; Kunze-Busch, M.C.; Kaanders, J.H.A.M.

    2009-01-01

    BACKGROUND AND PURPOSE: To investigate the anal wall (Awall) sparing effect of an endorectal balloon (ERB) in 3D conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) for prostate cancer. MATERIALS AND METHODS: In 24 patients with localized prostate carcinoma, two planning

  16. Finding dose-volume constraints to reduce late rectal toxicity following 3D-conformal radiotherapy (3D-CRT) of prostate cancer

    International Nuclear Information System (INIS)

    Greco, Carlo; Mazzetta, Chiara; Cattani, Federica; Tosi, Giampiero; Castiglioni, Simona; Fodor, Andrei; Orecchia, Roberto

    2003-01-01

    Background and purpose: The rectum is known to display a dose-volume effect following high-dose 3D-conformal radiotherapy (3D-CRT). The aim of the study is to search for significant dose-volume combinations with the specific treatment technique and patient set-up currently used in our institution. Patients and methods: We retrospectively analyzed the dose-volume histograms (DVH) of 135 patients with stage T1b-T3b prostate cancer treated consecutively with 3D-CRT between 1996 and 2000 to a total dose of 76 Gy. The median follow-up was 28 months (range 12-62). All late rectal complications were scored using RTOG criteria. Time to late toxicity was assessed using the Kaplan-Meyer method. The association between variables at baseline and ≥2 rectal toxicity was tested using χ 2 test or Fisher's exact test. A multivariate analysis using logistic regression was performed. Results: Late rectal toxicity grade ≥2 was observed in 24 of the 135 patients (17.8%). A 'grey area' of increased risk has been identified. Average DVHs of the bleeding and non-bleeding patients were generated. The area under the percent volume DVH for the rectum of the bleeding patients was significantly higher than that of patients without late rectal toxicity. On multivariate analysis the correlation between the high risk DVHs and late rectal bleeding was confirmed. Conclusions: The present analysis confirms the role of the rectal DVH as a tool to discriminate patients undergoing high-dose 3D-CRT into a low and a high risk of developing late rectal bleeding. Based on our own results and taking into account the data published in the literature, we have been able to establish new dose-volume constraints for treatment planning: if possible, the percentage of rectal volume exposed to 40, 50, 60, 72 and 76 Gy should be limited to 60, 50, 25, 15 and 5%, respectively

  17. Comparison of Toxicity Between Intensity-Modulated Radiotherapy and 3-Dimensional Conformal Radiotherapy for Locally Advanced Non-small-cell Lung Cancer.

    Science.gov (United States)

    Ling, Diane C; Hess, Clayton B; Chen, Allen M; Daly, Megan E

    2016-01-01

    The role of intensity-modulated radiotherapy (IMRT) in reducing treatment-related toxicity for locally advanced non-small-cell lung cancer (NSCLC) remains incompletely defined. We compared acute toxicity and oncologic outcomes in a large cohort of patients treated with IMRT or 3-dimensional conformal radiotherapy (3-DCRT), with or without elective nodal irradiation (ENI). A single-institution retrospective review was performed evaluating 145 consecutive patients with histologically confirmed stage III NSCLC treated with definitive chemoradiotherapy. Sixty-five (44.8%) were treated with 3-DCRT using ENI, 43 (30.0%) with 3-DCRT using involved-field radiotherapy (IFRT), and 37 (25.5%) with IMRT using IFRT. All patients received concurrent chemotherapy. Comparison of acute toxicities by treatment technique (IMRT vs. 3-DCRT) and extent of nodal irradiation (3-DCRT-IFRT vs. 3-DCRT-ENI) was performed for grade 2 or higher esophagitis or pneumonitis, number of acute hospitalizations, incidence of opioid requirement, percutaneous endoscopic gastrostomy utilization, and percentage weight loss during treatment. Local control and overall survival were analyzed by the Kaplan-Meier method. We identified no significant differences in any measures of acute toxicity by treatment technique or extent of nodal irradiation. There was a trend toward lower rates of grade 2 or higher pneumonitis among IMRT patients compared to 3-DCRT patients (5.4% vs. 23.0%; P = .065). Local control and overall survival were similar between cohorts. Acute and subacute toxicities were similar for patients treated with IMRT and with 3-DCRT with or without ENI, with a nonsignificant trend toward a reduction in pneumonitis with IMRT. Larger studies are needed to better define which patients will benefit from IMRT. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Factors influencing conformity index in radiotherapy for non-small cell lung cancer.

    LENUS (Irish Health Repository)

    Brennan, Sinead M

    2010-01-01

    The radiotherapy conformity index (CI) is a useful tool to quantitatively assess the quality of radiotherapy treatment plans, and represents the relationship between isodose distributions and target volume. A conformity index of unity implies high planning target volume (PTV) coverage and minimal unnecessary irradiation of surrounding tissues. We performed this analysis to describe the CI for lung cancer 3-dimensional conformal radiotherapy (3DCRT) and to identify clinical and technical determinants of CI, as it is not known which factors are associated with good quality 3D conformal radiotherapy treatment planning. Radiotherapy treatment plans from a database of 52 patients with inoperable Stage 1 to 3b lung cancer, on a hypofractionated 3DCRT trial were evaluated. A CI was calculated for all plans using the definition of the ICRU 62:CI = (TV\\/PTV), which is the quotient of the treated volume (TV) and the PTV. Data on patient, tumor, and planning variables, which could influence CI, were recorded and analyzed. Mean CI was 2.01 (range = 1.06-3.8). On univariate analysis, PTV (p = 0.023), number of beams (p = 0.036), medial vs. lateral tumor location (p = 0.016), and increasing tumor stage (p = 0.041) were associated with improved conformity. On multiple regression analysis, factors found to be associated with CI included central vs. peripheral tumor location (p = 0.041) and PTV size (p = 0.058). The term 3DCRT is used routinely in the literature, without any indication of the degree of conformality. We recommend routine reporting of conformity indices. Conformity indices may be affected by both planning variables and tumor factors.

  19. Propensity Score-based Comparison of Long-term Outcomes With 3-Dimensional Conformal Radiotherapy vs Intensity-Modulated Radiotherapy for Esophageal Cancer

    International Nuclear Information System (INIS)

    Lin, Steven H.; Wang Lu; Myles, Bevan; Thall, Peter F.; Hofstetter, Wayne L.; Swisher, Stephen G.; Ajani, Jaffer A.; Cox, James D.; Komaki, Ritsuko; Liao Zhongxing

    2012-01-01

    Purpose: Although 3-dimensional conformal radiotherapy (3D-CRT) is the worldwide standard for the treatment of esophageal cancer, intensity modulated radiotherapy (IMRT) improves dose conformality and reduces the radiation exposure to normal tissues. We hypothesized that the dosimetric advantages of IMRT should translate to substantive benefits in clinical outcomes compared with 3D-CRT. Methods and Materials: An analysis was performed of 676 nonrandomized patients (3D-CRT, n=413; IMRT, n=263) with stage Ib-IVa (American Joint Committee on Cancer 2002) esophageal cancers treated with chemoradiotherapy at a single institution from 1998-2008. An inverse probability of treatment weighting and inclusion of propensity score (treatment probability) as a covariate were used to compare overall survival time, interval to local failure, and interval to distant metastasis, while accounting for the effects of other clinically relevant covariates. The propensity scores were estimated using logistic regression analysis. Results: A fitted multivariate inverse probability weighted-adjusted Cox model showed that the overall survival time was significantly associated with several well-known prognostic factors, along with the treatment modality (IMRT vs 3D-CRT, hazard ratio 0.72, P<.001). Compared with IMRT, 3D-CRT patients had a significantly greater risk of dying (72.6% vs 52.9%, inverse probability of treatment weighting, log-rank test, P<.0001) and of locoregional recurrence (P=.0038). No difference was seen in cancer-specific mortality (Gray's test, P=.86) or distant metastasis (P=.99) between the 2 groups. An increased cumulative incidence of cardiac death was seen in the 3D-CRT group (P=.049), but most deaths were undocumented (5-year estimate, 11.7% in 3D-CRT vs 5.4% in IMRT group, Gray's test, P=.0029). Conclusions: Overall survival, locoregional control, and noncancer-related death were significantly better after IMRT than after 3D-CRT. Although these results need

  20. Anal wall sparing effect of an endorectal balloon in 3D conformal and intensity-modulated prostate radiotherapy.

    Science.gov (United States)

    Smeenk, Robert Jan; van Lin, Emile N J Th; van Kollenburg, Peter; Kunze-Busch, Martina; Kaanders, Johannes H A M

    2009-10-01

    To investigate the anal wall (Awall) sparing effect of an endorectal balloon (ERB) in 3D conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) for prostate cancer. In 24 patients with localized prostate carcinoma, two planning CT-scans were performed: with and without ERB. A prostate planning target volume (PTV) was defined, and the Awall was delineated, using two different methods. Three-field and 4-field 3D-CRT plans, and IMRT plans were generated with a prescription dose of 78Gy. In 144 treatment plans, the minimum dose (D(min)), maximum dose (D(max)), and mean dose (D(mean)) to the Awall were calculated, as well as the Awall volumes exposed to doses ranging from >or=20Gy to >or=70Gy (V(20)-V(70), respectively). In the 3D-CRT plans, an ERB significantly reduced D(mean), D(max), and V(30)-V(70). For IMRT all investigated dose parameters were significantly reduced by the ERB. The absolute reduction of D(mean) was 12Gy in 3D-CRT and was 7.5Gy in IMRT for both methods of Awall delineation. Application of an ERB showed a significant Awall sparing effect in both 3D-CRT and IMRT. This may lead to reduced late anal toxicity in prostate radiotherapy.

  1. Bladder radiotherapy treatment: A retrospective comparison of 3-dimensional conformal radiotherapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy plans

    Energy Technology Data Exchange (ETDEWEB)

    Pasciuti, Katia, E-mail: k.pasciuti@virgilio.it [Department of Radiotherapy Physics, Royal Free Hospital, London (United Kingdom); Kuthpady, Shrinivas [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom); Anderson, Anne; Best, Bronagh [Department of Radiotherapy Physics, Royal Free Hospital, London (United Kingdom); Waqar, Saleem; Chowdhury, Subhra [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom)

    2017-04-01

    To examine tumor's and organ's response when different radiotherapy plan techniques are used. Ten patients with confirmed bladder tumors were first treated using 3-dimensional conformal radiotherapy (3DCRT) and subsequently the original plans were re-optimized using the intensity-modulated radiation treatment (IMRT) and volumetric-modulated arc therapy (VMAT)-techniques. Targets coverage in terms of conformity and homogeneity index, TCP, and organs' dose limits, including integral dose analysis were evaluated. In addition, MUs and treatment delivery times were compared. Better minimum target coverage (1.3%) was observed in VMAT plans when compared to 3DCRT and IMRT ones confirmed by a statistically significant conformity index (CI) results. Large differences were observed among techniques in integral dose results of the femoral heads. Even if no statistically significant differences were reported in rectum and tissue, a large amount of energy deposition was observed in 3DCRT plans. In any case, VMAT plans provided better organs and tissue sparing confirmed also by the normal tissue complication probability (NTCP) analysis as well as a better tumor control probability (TCP) result. Our analysis showed better overall results in planning using VMAT techniques. Furthermore, a total time reduction in treatment observed among techniques including gantry and collimator rotation could encourage using the more recent one, reducing target movements and patient discomfort.

  2. Simultaneous integrated boost intensity-modulated radiotherapy versus 3-dimensional conformal radiotherapy in preoperative concurrent chemoradiotherapy for locally advanced rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Bong Kyung; Kang, Min Kyul; Kim, Jae Chul [Dept. of Radiation Oncology, Kyungpook National University School of Medicine, Daegu (Korea, Republic of); Kim, Min Young; Choi, Gyu Seog; Kim, Jong Gwang; Kang, Byung Woog; Kim, Hye Jin; Park, Soo Yeun [Kyungpook National University Chilgok Hospital, Kyungpook National University School of Medicine, Daegu (Korea, Republic of)

    2017-09-15

    To evaluate the feasibility of simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) for preoperative concurrent chemoradiotherapy (PCRT) in locally advanced rectal cancer (LARC), by comparing with 3-dimensional conformal radiotherapy (3D-CRT). Patients who were treated with PCRT for LARC from 2015 January to 2016 December were retrospectively enrolled. Total doses of 45 Gy to 50.4 Gy with 3D-CRT or SIB-IMRT were administered concomitantly with 5-fluorouracil plus leucovorin or capecitabine. Surgery was performed 8 weeks after PCRT. Between PCRT and surgery, one cycle of additional chemotherapy was administered. Pathologic tumor responses were compared between SIB-IMRT and 3D-CRT groups. Acute gastrointestinal, genitourinary, hematologic, and skin toxicities were compared between the two groups based on the RTOG toxicity criteria. SIB-IMRT was used in 53 patients, and 3D-CRT in 41 patients. After PCRT, no significant differences were noted in tumor responses, pathologic complete response (9% vs. 7%; p = 1.000), pathologic tumor regression Grade 3 or higher (85% vs. 71%; p = 0.096), and R0 resection (87% vs. 85%; p = 0.843). Grade 2 genitourinary toxicities were significantly lesser in the SIB-IMRT group (8% vs. 24%; p = 0.023), but gastrointestinal toxicities were not different across the two groups. SIB-IMRT showed lower GU toxicity and similar tumor responses when compared with 3D-CRT in PCRT for LARC.

  3. A Comparison of Helical Intensity-Modulated Radiotherapy, Intensity-Modulated Radiotherapy, and 3D-Conformal Radiation Therapy for Pancreatic Cancer

    International Nuclear Information System (INIS)

    Poppe, Matthew M.; Narra, Venkat; Yue, Ning J.; Zhou Jinghao; Nelson, Carl; Jabbour, Salma K.

    2011-01-01

    We assessed dosimetric differences in pancreatic cancer radiotherapy via helical intensity-modulated radiotherapy (HIMRT), linac-based IMRT, and 3D-conformal radiation therapy (3D-CRT) with regard to successful plan acceptance and dose to critical organs. Dosimetric analysis was performed in 16 pancreatic cases that were planned to 54 Gy; both post-pancreaticoduodenectomy (n = 8) and unresected (n = 8) cases were compared. Without volume modification, plans met constraints 75% of the time with HIMRT and IMRT and 13% with 3D-CRT. There was no statistically significantly improvement with HIMRT over conventional IMRT in reducing liver V35, stomach V45, or bowel V45. HIMRT offers improved planning target volume (PTV) dose homogeneity compared with IMRT, averaging a lower maximum dose and higher volume receiving the prescription dose (D100). HIMRT showed an increased mean dose over IMRT to bowel and liver. Both HIMRT and IMRT offer a statistically significant improvement over 3D-CRT in lowering dose to liver, stomach, and bowel. The results were similar for both unresected and resected patients. In pancreatic cancer, HIMRT offers improved dose homogeneity over conventional IMRT and several significant benefits to 3D-CRT. Factors to consider before incorporating IMRT into pancreatic cancer therapy are respiratory motion, dose inhomogeneity, and mean dose.

  4. Patterns of failure in children with medulloblastoma treated with 3D conformal radiotherapy

    International Nuclear Information System (INIS)

    Skowronska-Gardas, Anna; Chojnacka, Marzanna; Morawska-Kaczynska, Marzena; Perek, Danuta; Perek-Polnik, Marta

    2007-01-01

    Background and purpose: Craniospinal irradiation for medulloblastoma is one of the most complex techniques employed in radiotherapy. Many reports stress the impact of irradiation quality on survival in these patients. Our report presents the outcome and patterns of failure for 95 patients treated with 3D conformal radiotherapy (3D-CRT). Materials and methods: From 1998 to 2003, 95 children with medulloblastoma received 3D conformal radiotherapy. All of them were previously treated with surgery and chemotherapy. The brain and upper spinal cord were treated with two lateral 6 MV photon fields. In four patients, the cribriform plate was irradiated by the additional field. For primary tumour bed we applied two or three photon beams. Spinal cord was irradiated either with 18-20 MeV electron fields or with a mixed beam. Results: With a median follow-up of 48 months, 32/95 patients suffered a multifocal (21) or isolated (11) recurrence. We evaluated every primary site of failure. In all patients, the recurrence appeared within the isodose level of 95-100%. Conclusions: Patterns of failure in medulloblastoma patients treated with 3D conformal radiotherapy indicated that the relapse was mainly associated with poor response to pre-irradiation chemotherapy. We believe that 3D conformal radiotherapy allows avoiding failures, related to radiotherapy uncertainties

  5. Anal wall sparing effect of an endorectal balloon in 3D conformal and intensity-modulated prostate radiotherapy

    International Nuclear Information System (INIS)

    Smeenk, Robert Jan; Lin, Emile N.J.Th. van; Kollenburg, Peter van; Kunze-Busch, Martina; Kaanders, Johannes H.A.M.

    2009-01-01

    Background and purpose: To investigate the anal wall (Awall) sparing effect of an endorectal balloon (ERB) in 3D conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) for prostate cancer. Materials and methods: In 24 patients with localized prostate carcinoma, two planning CT-scans were performed: with and without ERB. A prostate planning target volume (PTV) was defined, and the Awall was delineated, using two different methods. Three-field and 4-field 3D-CRT plans, and IMRT plans were generated with a prescription dose of 78 Gy. In 144 treatment plans, the minimum dose (D min ), maximum dose (D max ), and mean dose (D mean ) to the Awall were calculated, as well as the Awall volumes exposed to doses ranging from ≥20 Gy to ≥70 Gy (V 20 - V 70 , respectively). Results: In the 3D-CRT plans, an ERB significantly reduced D mean , D max , and V 30 - V 70 . For IMRT all investigated dose parameters were significantly reduced by the ERB. The absolute reduction of D mean was 12 Gy in 3D-CRT and was 7.5 Gy in IMRT for both methods of Awall delineation. Conclusions: Application of an ERB showed a significant Awall sparing effect in both 3D-CRT and IMRT. This may lead to reduced late anal toxicity in prostate radiotherapy.

  6. Improvement in toxicity in high risk prostate cancer patients treated with image-guided intensity-modulated radiotherapy compared to 3D conformal radiotherapy without daily image guidance.

    Science.gov (United States)

    Sveistrup, Joen; af Rosenschöld, Per Munck; Deasy, Joseph O; Oh, Jung Hun; Pommer, Tobias; Petersen, Peter Meidahl; Engelholm, Svend Aage

    2014-02-04

    Image-guided radiotherapy (IGRT) facilitates the delivery of a very precise radiation dose. In this study we compare the toxicity and biochemical progression-free survival between patients treated with daily image-guided intensity-modulated radiotherapy (IG-IMRT) and 3D conformal radiotherapy (3DCRT) without daily image guidance for high risk prostate cancer (PCa). A total of 503 high risk PCa patients treated with radiotherapy (RT) and endocrine treatment between 2000 and 2010 were retrospectively reviewed. 115 patients were treated with 3DCRT, and 388 patients were treated with IG-IMRT. 3DCRT patients were treated to 76 Gy and without daily image guidance and with 1-2 cm PTV margins. IG-IMRT patients were treated to 78 Gy based on daily image guidance of fiducial markers, and the PTV margins were 5-7 mm. Furthermore, the dose-volume constraints to both the rectum and bladder were changed with the introduction of IG-IMRT. The 2-year actuarial likelihood of developing grade > = 2 GI toxicity following RT was 57.3% in 3DCRT patients and 5.8% in IG-IMRT patients (p analysis, 3DCRT was associated with a significantly increased risk of developing grade > = 2 GI toxicity compared to IG-IMRT (p analysis there was no difference in biochemical progression-free survival between 3DCRT and IG-IMRT. The difference in toxicity can be attributed to the combination of the IMRT technique with reduced dose to organs-at-risk, daily image guidance and margin reduction.

  7. Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Crowe, Scott B [Science and Engineering Faculty, Queensland University of Technology, Brisbane, Queensland (Australia); Kairn, Tanya [Science and Engineering Faculty, Queensland University of Technology, Brisbane, Queensland (Australia); Premion, Wesley Medical Centre, Brisbane, Queensland (Australia); Middlebrook, Nigel; Hill, Brendan; Christie, David R H; Knight, Richard T [Premion, Wesley Medical Centre, Brisbane, Queensland (Australia); Kenny, John [Australian Clinical Dosimetry Services, Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Victoria (Australia); Langton, Christian M; Trapp, Jamie V [Science and Engineering Faculty, Queensland University of Technology, Brisbane, Queensland (Australia)

    2013-12-15

    This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT.

  8. Comparative dosimetric study of three-dimensional conformal, dynamic conformal arc, and intensity-modulated radiotherapy for brain tumor treatment using Novalis system

    International Nuclear Information System (INIS)

    Ding Meisong; Newman, Francis M.S.; Kavanagh, Brian D.; Stuhr, Kelly M.S.; Johnson, Tim K.; Gaspar, Laurie E.

    2006-01-01

    Purpose: To investigate the dosimetric differences among three-dimensional conformal radiotherapy (3D-CRT), dynamic conformal arc therapy (DCAT), and intensity-modulated radiotherapy (IMRT) for brain tumor treatment. Methods and Materials: Fifteen patients treated with Novalis were selected. We performed 3D-CRT, DCAT, and IMRT plans for all patients. The margin for the planning target volume (PTV) was 1 mm, and the specific prescription dose was 90% for all plans. The target coverage at the prescription dose, conformity index (CI), and heterogeneity index were analyzed for all plans. Results: For small tumors (PTV ≤2 cm 3 ), the three dosimetric parameters had approximate values for both 3D-CRT and DCAT plans. The CI for the IMRT plans was high. For medium tumors (PTV >2 to ≤100 cm 3 ), the three plans were competitive with each other. The IMRT plans had a greater CI, better target coverage at the prescription dose, and a better heterogeneity index. For large tumors (PTV >100 cm 3 ), the IMRT plan had good target coverage at the prescription dose and heterogeneity index and approximate CI values as those in the 3D-CRT and DCAT plans. Conclusion: The results of our study have shown that DCAT is suitable for most cases in the treatment of brain tumors. For a small target, 3D-CRT is useful, and IMRT is not recommended. For larger tumors, IMRT is superior to 3D-CRT and very competitive in sparing critical structures, especially for big tumors

  9. Improvement in toxicity in high risk prostate cancer patients treated with image-guided intensity-modulated radiotherapy compared to 3D conformal radiotherapy without daily image guidance

    International Nuclear Information System (INIS)

    Sveistrup, Joen; Rosenschöld, Per Munck af; Deasy, Joseph O; Oh, Jung Hun; Pommer, Tobias; Petersen, Peter Meidahl; Engelholm, Svend Aage

    2014-01-01

    Image-guided radiotherapy (IGRT) facilitates the delivery of a very precise radiation dose. In this study we compare the toxicity and biochemical progression-free survival between patients treated with daily image-guided intensity-modulated radiotherapy (IG-IMRT) and 3D conformal radiotherapy (3DCRT) without daily image guidance for high risk prostate cancer (PCa). A total of 503 high risk PCa patients treated with radiotherapy (RT) and endocrine treatment between 2000 and 2010 were retrospectively reviewed. 115 patients were treated with 3DCRT, and 388 patients were treated with IG-IMRT. 3DCRT patients were treated to 76 Gy and without daily image guidance and with 1–2 cm PTV margins. IG-IMRT patients were treated to 78 Gy based on daily image guidance of fiducial markers, and the PTV margins were 5–7 mm. Furthermore, the dose-volume constraints to both the rectum and bladder were changed with the introduction of IG-IMRT. The 2-year actuarial likelihood of developing grade > = 2 GI toxicity following RT was 57.3% in 3DCRT patients and 5.8% in IG-IMRT patients (p < 0.001). For GU toxicity the numbers were 41.8% and 29.7%, respectively (p = 0.011). On multivariate analysis, 3DCRT was associated with a significantly increased risk of developing grade > = 2 GI toxicity compared to IG-IMRT (p < 0.001, HR = 11.59 [CI: 6.67-20.14]). 3DCRT was also associated with an increased risk of developing GU toxicity compared to IG-IMRT. The 3-year actuarial biochemical progression-free survival probability was 86.0% for 3DCRT and 90.3% for IG-IMRT (p = 0.386). On multivariate analysis there was no difference in biochemical progression-free survival between 3DCRT and IG-IMRT. The difference in toxicity can be attributed to the combination of the IMRT technique with reduced dose to organs-at-risk, daily image guidance and margin reduction

  10. Effects of three-dimensional conformal radiotherapy, indensity modulated radiotherapy, and conventional radiotherapy ON treatment of esophageal cancer

    Directory of Open Access Journals (Sweden)

    Jian-Jun Han

    2016-07-01

    Full Text Available Objective: To compare the irradiation volume, short-term and long-term efficacy of conventional radiotherapy (CR, three-dimensional conformal radiotherapy (3D-CRT, and indensity modulated radiotherapy (IMRT in the treatment of esophageal cancer. Methods: A retrospective analysis method was adopted. The patients were divided into CR group (n=42, 3D-CRT group (n=45, and IMRT group (n=40. A follow-up visit was paid to collect the short-term and long-term efficacy, and the occurrence of adverse reactions. The gross tumor voluem (GTV, clinical target volume (CTV, planning target volume (PTV, and irradiation volume of organs (bilateral lungs, spinal cord, and heart at risk (OAR in the three groups were compared. Results: It was found by target volume comparison that the mean values of GTV, CTV, and PTV in the three groups were significantly increased (P0.05. The occurrence rate of adverse reactions in 3D-CRT group and IMRT group was significantly lower than that in CR group (P0.05. The difference of 1-year survival rate among the three groups was not statistically significant (P=0.144, but 3-year and 5-year survival rates in 3D-CRT group and IMRT group were significantly higher than those in CR group (P<0.05. Conclusions: 3D-CRT and IMRT can significantly enhance the short-term and long-term efficacy for esophageal cancer patients, and alleviate the radioactive damage; therefore, they are deserved to be widely recommended in the clinic.

  11. Dosimetric comparison between intensity-modulated with coplanar field and 3D conformal radiotherapy with noncoplanar field for postocular invasion tumor.

    Science.gov (United States)

    Wenyong, Tu; Lu, Liu; Jun, Zeng; Weidong, Yin; Yun, Li

    2010-01-01

    This study presents a dosimetric optimization effort aiming to compare noncoplanar field (NCF) on 3 dimensions conformal radiotherapy (3D-CRT) and coplanar field (CF) on intensity-modulated radiotherapy (IMRT) planning for postocular invasion tumor. We performed a planning study on the computed tomography data of 8 consecutive patients with localized postocular invasion tumor. Four fields NCF 3D-CRT in the transverse plane with gantry angles of 0-10 degrees , 30-45 degrees , 240-270 degrees , and 310-335 degrees degrees were isocentered at the center of gravity of the target volume. The geometry of the beams was determined by beam's eye view. The same constraints were prepared with between CF IMRT optimization and NCF 3D-CRT treatment. The maximum point doses (D max) for the different optic pathway structures (OPS) with NCF 3D-CRT treatment should differ in no more than 3% from those with the NCF IMRT plan. Dose-volume histograms (DVHs) were obtained for all targets and organ at risk (OAR) with both treatment techniques. Plans with NCF 3D-CRT and CF IMRT constraints on target dose in homogeneity were computed, as well as the conformity index (CI) and homogeneity index (HI) in the target volume. The PTV coverage was optimal with both NCF 3D-CRT and CF IMRT plans in the 8 tumor sites. No difference was noted between the two techniques for the average D(max) and D(min) dose. NCF 3D-CRT and CF IMRT will yield similar results on CI. However, HI was a significant difference between NCF 3D-CRT and CF IMRT plan (p 3D-CRT versus CF IMRT set-up is very slight. NCF3D-CRT is one of the treatment options for postocular invasion tumor. However, constraints for OARs are needed. 2010 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  12. Dosimetric Comparison Between Intensity-Modulated with Coplanar Field and 3D Conformal Radiotherapy with Noncoplanar Field for Postocular Invasion Tumor

    International Nuclear Information System (INIS)

    Tu Wenyong; Liu Lu; Zeng Jun; Yin Weidong; Li Yun

    2010-01-01

    This study presents a dosimetric optimization effort aiming to compare noncoplanar field (NCF) on 3 dimensions conformal radiotherapy (3D-CRT) and coplanar field (CF) on intensity-modulated radiotherapy (IMRT) planning for postocular invasion tumor. We performed a planning study on the computed tomography data of 8 consecutive patients with localized postocular invasion tumor. Four fields NCF 3D-CRT in the transverse plane with gantry angles of 0-10 deg., 30-45 deg., 240-270 deg., and 310-335 deg. degrees were isocentered at the center of gravity of the target volume. The geometry of the beams was determined by beam's eye view. The same constraints were prepared with between CF IMRT optimization and NCF 3D-CRT treatment. The maximum point doses (D max) for the different optic pathway structures (OPS) with NCF 3D-CRT treatment should differ in no more than 3% from those with the NCF IMRT plan. Dose-volume histograms (DVHs) were obtained for all targets and organ at risk (OAR) with both treatment techniques. Plans with NCF 3D-CRT and CF IMRT constraints on target dose in homogeneity were computed, as well as the conformity index (CI) and homogeneity index (HI) in the target volume. The PTV coverage was optimal with both NCF 3D-CRT and CF IMRT plans in the 8 tumor sites. No difference was noted between the two techniques for the average D max and D min dose. NCF 3D-CRT and CF IMRT will yield similar results on CI. However, HI was a significant difference between NCF 3D-CRT and CF IMRT plan (p < 0.001). Physical endpoints for target showed the mean target dose to be low in the CF IMRT plan, caused by a large target dose in homogeneity (p < 0.001). The impact of NCF 3D-CRT versus CF IMRT set-up is very slight. NCF3D-CRT is one of the treatment options for postocular invasion tumor. However, constraints for OARs are needed.

  13. Comparison of Heart and Coronary Artery Doses Associated With Intensity-Modulated Radiotherapy Versus Three-Dimensional Conformal Radiotherapy for Distal Esophageal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kole, Thomas P.; Aghayere, Osarhieme; Kwah, Jason [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Yorke, Ellen D. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Goodman, Karyn A., E-mail: goodmank@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2012-08-01

    Purpose: To compare heart and coronary artery radiation exposure using intensity-modulated radiotherapy (IMRT) vs. four-field three-dimensional conformal radiotherapy (3D-CRT) treatment plans for patients with distal esophageal cancer undergoing chemoradiation. Methods and Materials: Nineteen patients with distal esophageal cancers treated with IMRT from March 2007 to May 2008 were identified. All patients were treated to 50.4 Gy with five-field IMRT plans. Theoretical 3D-CRT plans with four-field beam arrangements were generated. Dose-volume histograms of the planning target volume, heart, right coronary artery, left coronary artery, and other critical normal tissues were compared between the IMRT and 3D-CRT plans, and selected parameters were statistically evaluated using the Wilcoxon rank-sum test. Results: Intensity-modulated radiotherapy treatment planning showed significant reduction (p < 0.05) in heart dose over 3D-CRT as assessed by average mean dose (22.9 vs. 28.2 Gy) and V30 (24.8% vs. 61.0%). There was also significant sparing of the right coronary artery (average mean dose, 23.8 Gy vs. 35.5 Gy), whereas the left coronary artery showed no significant improvement (mean dose, 11.2 Gy vs. 9.2 Gy), p = 0.11. There was no significant difference in percentage of total lung volume receiving at least 10, 15, or 20 Gy or in the mean lung dose between the planning methods. There were also no significant differences observed for the kidneys, liver, stomach, or spinal cord. Intensity-modulated radiotherapy achieved a significant improvement in target conformity as measured by the conformality index (ratio of total volume receiving 95% of prescription dose to planning target volume receiving 95% of prescription dose), with the mean conformality index reduced from 1.56 to 1.30 using IMRT. Conclusions: Treatment of patients with distal esophageal cancer using IMRT significantly decreases the exposure of the heart and right coronary artery when compared with 3D-CRT

  14. Intensity-Modulated Radiotherapy versus 3-Dimensional Conformal Radiotherapy Strategies for Locally Advanced Non-Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Uğur Selek

    2014-12-01

    Full Text Available Chemoradiotherapy is the current standard of care in patients with advanced inoperable stage IIIA or IIIB non-small cell lung cancer (NSCLC. Three-dimensional radiotherapy (3DCRT has been a trusted method for a long time and has well-known drawbacks, most of which could be improved by Intensity Modulated Radiotherapy (IMRT. IMRT is not currently the standard treatment of locally advanced NSCLC, but almost all patients could benefit to a degree in organ at risk sparing, dose coverage conformality, or dose escalation. The most critical step for a radiation oncology department is to strictly evaluate its own technical and physical capabilities to determine the ability of IMRT to deliver an optimal treatment plan. This includes calculating the internal tumor motion (ideally 4DCT or equivalent techniques, treatment planning software with an up-to-date heterogeneity correction algorithm, and daily image guidance. It is crucial to optimise and individualise the therapeutic ratio for each patient during the decision of 3DCRT versus IMRT. The current literature rationalises the increasing use of IMRT, including 4D imaging plus PET/CT, and encourages the applicable knowledge-based and individualised dose escalation using advanced daily image-guided radiotherapy.

  15. Prone Hypofractionated Whole-Breast Radiotherapy Without a Boost to the Tumor Bed: Comparable Toxicity of IMRT Versus a 3D Conformal Technique

    Energy Technology Data Exchange (ETDEWEB)

    Hardee, Matthew E.; Raza, Shahzad; Becker, Stewart J.; Jozsef, Gabor; Lymberis, Stella C. [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States); Hochman, Tsivia; Goldberg, Judith D. [Division of Biostatistics, New York University School of Medicine, New York, NY (United States); DeWyngaert, Keith J. [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States); Formenti, Silvia C., E-mail: silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States)

    2012-03-01

    Purpose: We report a comparison of the dosimetry and toxicity of three-dimensional conformal radiotherapy (3D-CRT) vs. intensity-modulated radiotherapy (IMRT) among patients treated in the prone position with the same fractionation and target of the hypofractionation arm of the Canadian/Whelan trial. Methods and Materials: An institutional review board-approved protocol identified a consecutive series of early-stage breast cancer patients treated according to the Canadian hypofractionation regimen but in the prone position. Patients underwent IMRT treatment planning and treatment if the insurance carrier approved reimbursement for IMRT; in case of refusal, a 3D-CRT plan was used. A comparison of the dosimetric and toxicity outcomes during the acute, subacute, and long-term follow-up of the two treatment groups is reported. Results: We included 97 consecutive patients with 100 treatment plans in this study (3 patients with bilateral breast cancer); 40 patients were treated with 3D-CRT and 57 with IMRT. IMRT significantly reduced the maximum dose (Dmax median, 109.96% for 3D-CRT vs. 107.28% for IMRT; p < 0.0001, Wilcoxon test) and improved median dose homogeneity (median, 1.15 for 3D-CRT vs. 1.05 for IMRT; p < 0.0001, Wilcoxon test) when compared with 3D-CRT. Acute toxicity consisted primarily of Grade 1 to 2 dermatitis and occurred in 92% of patients. Grade 2 dermatitis occurred in 13% of patients in the 3D-CRT group and 2% in the IMRT group. IMRT moderately decreased rates of acute pruritus (p = 0.03, chi-square test) and Grade 2 to 3 subacute hyperpigmentation (p = 0.01, Fisher exact test). With a minimum of 6 months' follow-up, the treatment was similarly well tolerated in either group, including among women with large breast volumes. Conclusion: Hypofractionated breast radiotherapy is well tolerated when treating patients in the prone position, even among those with large breast volumes. Breast IMRT significantly improves dosimetry but yields only a modest

  16. Comparison of dose distribution between 3DCRT and IMRT in middle thoracic and under thoracic esophageal carcinoma

    International Nuclear Information System (INIS)

    Li Dingjie; Liu Hailong; Mao Ronghu; Liu Ru; Guo Xiaoqi; Lei Hongchang; Wang Jianhua

    2011-01-01

    Objective: To compare the dose distribution between three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) in treating esophageal carcinoma (middle thoracic section and under thoracic section) and to select reasonable treatment methods for esophagus cancer. Methods: Ten cases with cancer of the middle thoracic section and under thoracic section esophagus were chosen for a retrospective treatment-planning study. 3DCRT and IMRT plans were created for each patient: Some critical indicators were evolved in evaluating the treatment plans of IMRT (5B and 7B) and 3DCRT (3B), such as, PTV coverage and dose-volumes to irradiated normal structures. Evaluation indicators: prescription of 50 Gy. total lung volume (V5, V10, V20), mean lung dose (MLD), spinal cord (Dmax), heart (V40) and conformality index (CI). Each plan was evaluated with respect to dose distribution,dose-volume histograms (DVHs), and additional dosimetric endpoints described below. Results: There is no significance of CRT and IMRT technique in protection of total lung volume,mean lung dose, spinal cord (Dmax), target, CI and heart. Conclusion: As To radiotherapy of esophagus cancer of the middle thoracic section and under thoracic section, IMRT has no advantage compared with 3DCRT, the selection of plan should be adapted to the situations of every patient. (authors)

  17. Persistently better treatment planning results of intensity-modulated (IMRT) over conformal radiotherapy (3D-CRT) in prostate cancer patients with significant variation of clinical target volume and/or organs-at-risk

    International Nuclear Information System (INIS)

    Fenoglietto, Pascal; Laliberte, Benoit; Allaw, Ali; Ailleres, Norbert; Idri, Katia; Hay, Meng Huor; Moscardo, Carmen Llacer; Gourgou, Sophie; Dubois, Jean-Bernard; Azria, David

    2008-01-01

    Purpose: To compare the dose coverage of planning and clinical target volume (PTV, CTV), and organs-at-risk (OAR) between intensity-modulated (3D-IMRT) and conventional conformal radiotherapy (3D-CRT) before and after internal organ variation in prostate cancer. Methods and materials: We selected 10 patients with clinically significant interfraction volume changes. Patients were treated with 3D-IMRT to 80 Gy (minimum PTV dose of 76 Gy, excluding rectum). Fictitious, equivalent 3D-CRT plans (80 Gy at isocenter, with 95% isodose (76 Gy) coverage of PTV, with rectal blocking above 76 Gy) were generated using the same planning CT data set ('CT planning'). The plans were then also applied to a verification CT scan ('CT verify') obtained at a different moment. PTV, CTV, and OAR dose coverage were compared using non-parametric tests statistics for V95, V90 (% of the volume receiving ≥95 or 90% of the dose) and D50 (dose to 50% of the volume). Results: Mean V95 of the PTV for 'CT planning' was 94.3% (range, 88-99) vs 89.1% (range, 84-94.5) for 3D-IMRT and 3D-CRT (p = 0.005), respectively. Mean V95 of the CTV for 'CT verify' was 97% for both 3D-IMRT and 3D-CRT. Mean D50 of the rectum for 'CT planning' was 26.8 Gy (range, 22-35) vs 43.5 Gy (range, 33.5-50.5) for 3D-IMRT and 3D-CRT (p = 0.0002), respectively. For 'CT verify', this D50 was 31.1 Gy (range, 16.5-44) vs 44.2 Gy (range, 34-55) for 3D-IMRT and 3D-CRT (p = 0.006), respectively. V95 of the rectum was 0% for both plans for 'CT planning', and 2.3% (3D-IMRT) vs 2.1% (3D-CRT) for 'CT verify' (p = non-sig.). Conclusion: Dose coverage of the PTV and OAR was better with 3D-IMRT for each patient and remained so after internal volume changes

  18. Comparison of radiotherapy dosimetry for 3D-CRT, IMRT, and SBRT based on electron density calibration

    International Nuclear Information System (INIS)

    Kartutik, K; Pawiro, S A; Wibowo, W E

    2016-01-01

    Accurate calculation of dose distribution affected by inhomogeneity tissue is required in radiotherapy planning. This study was performed to determine the ratio between radiotherapy planning using 3D-CRT, IMRT, and SBRT based on a calibrated curve of CT-number in the lung for different target's shape in 3D-CRT, IMRT, and spinal cord for SBRT. Calibration curves of CT-number were generated under measurement basis and introduced into TPS, then planning was performed for 3D-CRT, IMRT, and SBRT with 7, and 15 radiation fields. Afterwards, planning evaluation was performed by comparing the DVH curve, HI, and CI. 3D-CRT and IMRT produced the lowest HI at calibration curve of CIRS 002LFC with the value 0.24 and 10. Whereas SBRT produced the lowest HI on a linear calibration curve with a value of 0.361. The highest CI in IMRT and SBRT technique achieved using a linear calibration curve was 0.97 and 1.77 respectively. For 3D-CRT, the highest CI was obtained by using calibration curve of CIRS 062M with the value of 0.45. From the results of CI and HI, it is concluded that the calibration curve of CT-number does not significantly differ with Schneider's calibrated curve, and inverse planning gives a better result than forward planning. (paper)

  19. Factors of influence on acute skin toxicity of breast cancer patients treated with standard three-dimensional conformal radiotherapy (3D-CRT) after breast conserving surgery (BCS)

    International Nuclear Information System (INIS)

    Kraus-Tiefenbacher, Uta; Sfintizky, Andreas; Welzel, Grit; Simeonova, Anna; Sperk, Elena; Siebenlist, Kerstin; Mai, Sabine; Wenz, Frederik

    2012-01-01

    Standard 3D-CRT after BCS may cause skin toxicity with a wide range of intensity including acute effects like erythema or late effects. In order to reduce these side effects it is mandatory to identify potential factors of influence in breast cancer patients undergoing standard three-dimensional conformal radiation therapy (3D-CRT) of the breast and modern systemic therapy. Between 2006 and 2010 a total of 211 breast cancer patients (median age 52,4 years, range 24–77) after BCS consecutively treated in our institution with 3D-CRT (50 Gy whole breast photon radiotherapy followed by 16 Gy electron boost to the tumorbed) were evaluated with special focus on documented skin toxicity at the end of the 50 Gy-course. Standardized photodocumentation of the treated breast was done in each patient lying on the linac table with arms elevated. Skin toxicity was documented according to the common toxicity criteria (CTC)-score. Potential influencing factors were classified in three groups: patient-specific (smoking, age, breast size, body mass index = BMI, allergies), tumor-specific (tumorsize) and treatment-specific factors (antihormonal therapy with tamoxifen or aromatase inhibitors, chemotherapy). Uni- and multivariate statistical analyses were done using IBM SPSS version 19. After 50 Gy 3D-CRT to the whole breast 28.9% of all 211 patients had no erythema, 62.2% showed erythema grade 1 (G1) and 8.5% erythema grade 2. None of the patients had grade 3/4 (G3/4) erythema. In univariate analyses a significant influence or trend on the development of acute skin toxicities (erythema G0 versus G1 versus G2) was observed for larger breast volumes (p=0,004), smoking during radiation therapy (p=0,064) and absence of allergies (p=0,014) as well as larger tumorsize (p=0,009) and antihormonal therapy (p=0.005). Neither patient age, BMI nor choice of chemotherapy showed any significant effect on higher grade toxicity. In the multivariate analysis, factors associated with higher grade

  20. Risk of isolated nodal failure for non-small cell lung cancer (NSCLC) treated with the elective nodal irradiation (ENI) using 3D-conformal radiotherapy (3D-CRT) techniques--a retrospective analysis.

    Science.gov (United States)

    Kepka, Lucyna; Bujko, Krzysztof; Zolciak-Siwinska, Agnieszka

    2008-01-01

    To estimate retrospectively the rate of isolated nodal failures (INF) in NSCLC patients treated with the elective nodal irradiation (ENI) using 3D-conformal radiotherapy (3D-CRT). One hundred and eighty-five patients with I-IIIB stage treated with 3D-CRT in consecutive clinical trials differing in an extent of the ENI were analyzed. According to the extent of the ENI, two groups were distinguished: extended (n = 124) and limited (n = 61) ENI. INF was defined as regional nodal failure occurring without local progression. Cumulative Incidence of INF (CIINF) was evaluated by univariate and multivariate analysis with regard to prognostic factors. With a median follow up of 30 months, the two-year actuarial overall survival was 35%. The two-year CIINF rate was 12%. There were 16 (9%) INF, eight (6%) for extended and eight (13%) for limited ENI. In the univariate analysis bulky mediastinal disease (BMD), left side, higher N stage, and partial response to RT had a significant negative impact on the CIINF. BMD was the only independent predictor of the risk of incidence of the INF (p = 0.001). INF is more likely to occur in case of more advanced nodal status.

  1. Skin-sparing Helical Tomotherapy vs 3D-conformal Radiotherapy for Adjuvant Breast Radiotherapy: In Vivo Skin Dosimetry Study

    International Nuclear Information System (INIS)

    Capelle, Lisa; Warkentin, Heather; MacKenzie, Marc; Joseph, Kurian; Gabos, Zsolt; Pervez, Nadeem; Tankel, Keith; Chafe, Susan; Amanie, John; Ghosh, Sunita; Parliament, Matthew; Abdulkarim, Bassam

    2012-01-01

    Purpose: We investigated whether treatment-planning system (TPS)-calculated dose accurately reflects skin dose received for patients receiving adjuvant breast radiotherapy (RT) with standard three-dimensional conformal RT (3D-CRT) or skin-sparing helical tomotherapy (HT). Methods and Materials: Fifty patients enrolled in a randomized controlled trial investigating acute skin toxicity from adjuvant breast RT with 3D-CRT compared to skin-sparing HT, where a 5-mm strip of ipsilateral breast skin was spared. Thermoluminescent dosimetry or optically stimulated luminescence measurements were made in multiple locations and were compared to TPS-calculated doses. Skin dosimetric parameters and acute skin toxicity were recorded in these patients. Results: With HT there was a significant correlation between calculated and measured dose in the medial and lateral ipsilateral breast (r = 0.67, P V50 (1.4% vs 5.9%, respectively; P=.001) but higher skin V40 and skin V30 (71.7% vs 64.0%, P=.02; and 99.0% vs 93.8%, P=.001, respectively) than 3D-CRT plans. Conclusion: The 3D-CRT TPS more accurately reflected skin dose than the HT TPS, which tended to overestimate dose received by 14% in patients receiving adjuvant breast RT.

  2. IMRT vs. 2D-radiotherapy or 3D-conformal radiotherapy of nasopharyngeal carcinoma. Survival outcome in a Korean multi-institutional retrospective study (KROG 11-06)

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sung Ho; Cho, Kwan Ho [Proton Therapy Center, Research Institute and Hospital, National Cancer Center, Ilsandong-gu, Goyang-si Gyeonggi-do (Korea, Republic of); Lee, Chang-Geol; Keum, Ki Chang [Yonsei University College of Medicine, Department of Radiation Oncology, Seodaemun-gu, Seoul (Korea, Republic of); Kim, Yeon-Sil [Seoul St. Mary' s Hospital, College of Medicine, the Catholic University of Korea, Department of Radiation Oncology, Seocho-gu, Seoul (Korea, Republic of); Wu, Hong-Gyun; Kim, Jin Ho [Seoul National University College of Medicine, Department of Radiation Oncology, Jongno-gu, Seoul (Korea, Republic of); Ahn, Yong Chan; Oh, Dongryul [Samsung Medical Center, Sungkyunkwan University School of Medicine, Department of Radiation Oncology, Gangnam-gu, Seoul (Korea, Republic of); Lee, Jong Hoon [The Catholic University of Korea, College of Medicine, Department of Radiation Oncology, Paldal-gu, Suwon, Gyeonggi-do (Korea, Republic of)

    2016-06-15

    We compared treatment outcomes of two-dimensional radiotherapy (2D-RT), three-dimensional conformal radiotherapy (3D-CRT), and intensity-modulated radiotherapy (IMRT) in patients with nasopharyngeal carcinoma (NPC). In total, 1237 patients with cT1-4N0-3M0 NPC were retrospectively analyzed. Of these, 350, 390, and 497 were treated with 2D-RT, 3D-CRT, and IMRT, respectively. 3D-CRT and IMRT showed better 5-year overall survival (OS) rates (73.6 and 76.7 %, respectively) than did 2D-RT (5-year OS of 59.7 %, all p < 0.001). In T3-4 subgroup, IMRT was associated with a significantly better 5-year OS than was 2D-RT (70.7 vs. 50.4 %, respectively; p ≤ 0.001) and 3D-CRT (70.7 vs. 57.8 %, respectively; p = 0.011); however, the difference between the 2D-RT and 3D-CRT groups did not reach statistical significance (p = 0.063). In multivariate analyses of all patients, IMRT was a predictive factor for OS when compared with 2D-RT or 3D-CRT, as was 3D-CRT when compared with 2D-RT. Our study showed that 3D-CRT and IMRT were associated with a better local progression-free survival and OS than was 2D-RT in NPC. IMRT was significantly superior in terms of OS for advanced primary tumors (T3-4). (orig.) [German] Wir verglichen die Behandlungsergebnisse von zweidimensionaler Strahlentherapie (2D-RT), dreidimensionaler konformer Strahlentherapie (3D-CRT) und intensitaetsmodulierter Strahlentherapie (IMRT) bei Patienten mit Nasopharynxkarzinom (NPC). Insgesamt 1237 Patienten mit NPC im Stadium cT1-4/N0-3/M0 wurden rueckwirkend analysiert. Von diesen wurden jeweils 350, 390 und 497 mit 2D-RT, 3D-CRT und IMRT behandelt. 3D-CRT und IMRT zeigten eine bessere 5-Jahres-Gesamtueberlebensrate (5y-OS; jeweils 73,6 und 76,7%) als 2D-RT (59,7%; alle p < 0,001). In der Untergruppe T3-4 war die IMRT mit einer erheblich besseren 5y-OS verbunden als 2D-RT (jeweils 70,7 vs. 50,4%; p ≤ 0,001) und 3D-CRT (jeweils 70,7 vs. 57,8%; p = 0,011); jedoch gab es keinen Unterschied zwischen den Gruppen 2D

  3. The value of 18F-FDG PET in three-dimensional conformal radiotherapy of cancer

    International Nuclear Information System (INIS)

    Lv Huiqing; Zhang Zhongmin; Lv Zhonghong

    2006-01-01

    Three-dimensional conformal radiotherapy (3D-CRT) is based on an extensive use of modern medical imaging techniques. Delineation of the gross tumor volume and organs at risk constitutes one of the most important phases of conformal radiotherapy procedures. 18 F-fluorodeoxyglucose ( 18 F-FDG) PET possesses greater sensitivity and accuracy in detecting diseased lymph nodes, is an important staging examination for patients considered for radiation treatment with curative intent. 18 F-FDG PET has an important role in delineation of gross tumor volume for patients treated with three-dimensional conformal radiotherapy. (authors)

  4. Feasibility and efficacy of helical intensity-modulated radiotherapy for stage III non-small cell lung cancer in comparison with conventionally fractionated 3D-CRT.

    Science.gov (United States)

    He, Jian; Huang, Yan; Chen, Yixing; Shi, Shiming; Ye, Luxi; Hu, Yong; Zhang, Jianying; Zeng, Zhaochong

    2016-05-01

    The standard treatment for stage III non-small-cell lung cancer (NSCLC) is still 60 Gy in conventional fractions combined with concurrent chemotherapy; however, the resulting local controls are disappointing. The aim of this study was to compare and assess the feasibility and efficacy of hypofractionated chemoradiotherapy using helical tomotherapy (HT) with conventional fractionation as opposed to using three-dimensional conformal radiotherapy (3D-CRT) for stage III NSCLC. Sixty-nine patients with stage III (AJCC 7th edition) NSCLC who underwent definitive radiation treatment at our institution between July 2011 and November 2013 were reviewed and analyzed retrospectively. A dose of 60 Gy in 20 fractions was delivered in the HT group (n=34), whereas 60 Gy in 30 fractions in the 3D-CRT group (n=35). Primary endpoints were toxicity, overall response rate, overall survival (OS) and progression-free survival (PFS). The median follow-up period was 26.4 months. V20 (P=0.005), V30 (P=0.001), V40 (P=0.004), mean lung dose (P=0.000) and max dose of spinal cord (P=0.005) were significantly lower in the HT group than in the 3D-CRT group. There was no significant difference in the incidences of acute radiation pneumonitis (RP) ≥ grade 2 between the two groups, whereas the incidences of acute radiation esophagitis ≥ grade 2 were significantly lower in the HT group than in the 3D-CRT group (P=0.027). Two-year overall response rate was significantly higher in the HT group than in the 3D-CRT group (P=0.015). One- and 2-year OS rates were significantly higher in the HT group (95.0% and 68.7%, respectively) than in the 3D-CRT group (85.5% and 47.6%, respectively; P=0.0236). One- and 2-year PFS rates were significantly higher in the HT group (57.8% and 26.3%, respectively) than in the 3D-CRT group (32.7% and 11.4%, respectively; P=0.0351). Univariate analysis indicated that performance status (PS), T stage and radiotherapy technique were significant prognostic factors for both OS

  5. Does TomoDirect 3DCRT represent a suitable option for post-operative whole breast irradiation? A hypothesis-generating pilot study

    International Nuclear Information System (INIS)

    Borca, Valeria Casanova; La Porta, Maria Rosa; Cante, Domenico; Sciacero, Piera; Girelli, Giuseppe; Ricardi, Umberto; Tofani, Santi; Franco, Pierfrancesco; Catuzzo, Paola; Migliaccio, Fernanda; Zenone, Flora; Aimonetto, Stefania; Peruzzo, Andrea; Pasquino, Massimo; Russo, Giuliana

    2012-01-01

    This study investigates the use of TomoDirect TM 3DCRT for whole breast adjuvant radiotherapy (AWBRT) that represents a very attractive treatment opportunity, mainly for radiotherapy departments without conventional Linacs and only equipped with helical tomotherapy units. Plans were created for 17 breast cancer patients using TomoDirect in 3DCRT and IMRT modality and field-in-field 3DCRT planning (FIF) and compared in terms of PTV coverage, overdosage, homogeneity, conformality and dose to OARs. The possibility to define patient-class solutions for TD-3DCRT employment was investigated, correlating OARs dose constraints to patient specific anatomic parameters. TD-3DCRT showed PTV coverage and homogeneity significantly higher than TD-IMRT and FIF. PTV conformality was significantly better for FIF, while no differences were found between TD-3DCRT and TD-IMRT. TD-3DCRT showed mean values of the OARs dosimetric endpoints significantly higher than TD-IMRT; with respect to FIF, TD-3DCRT showed values significantly higher for lung V 20Gy , mean heart dose and V 25Gy , while contralateral lung maximum dose and contralateral breast mean dose resulted significantly lower. The Central Lung Distance (CLD) and the maximal Heart Distance (HD) resulted as useful clinical tools to predict the opportunity to employ TD-3DCRT: positive correlations were found between CLD and both V 20Gy and mean lung dose and between HD and both V 25Gy and the mean heart dose. TD-3DCRT showed a significantly shorter mean beam-on time than TD-IMRT. The present study showed that TD-3DCRT and TD-IMRT are two feasible and dosimetrically acceptable treatment approach for AWBRT, with an optimal PTV coverage and adequate OARs sparing. Some concerns might be raised in terms of dose to organs at risks if TD-3DCRT is applied to a general population. A correct patients clusterization according to simple quantitative anatomic measures, would help to correctly allocate patients to the appropriate treatment

  6. Radiotherapy for Adult Medulloblastoma: Evaluation of Helical Tomotherapy, Volumetric Intensity Modulated Arc Therapy, and Three-Dimensional Conformal Radiotherapy and the Results of Helical Tomotherapy Therapy

    Directory of Open Access Journals (Sweden)

    Sun Zong-wen

    2018-01-01

    Full Text Available Introduction. All adult medulloblastoma (AMB patients should be treated with craniospinal irradiation (CSI postoperatively. Because of the long irradiation range, multiple radiation fields must be designed for conventional radiotherapy technology. CSI can be completed in only one session with helical tomotherapy (HT. We evaluated the dose of HT, volumetric intensity modulated arc therapy (VMAT, and three-dimensional conformal radiotherapy (3D-CRT of AMB and the results of 5 cases of AMB treated with HT. Methods. Complete craniospinal and posterior cranial fossa irradiation with HT, VMAT, and 3D-CRT and dose evaluation were performed. And results of 5 cases of AMB treated with HT were evaluated. Results. A large volume of tissue was exposed to low dose radiation in the organs at risk (OAR, while a small volume was exposed to high dose radiation with HT. The conformity and uniformity of the targets were good with HT and VMAT, and the volume of targets exposed to high dose with VMAT was larger than that of HT. The uniformity of 3D-CRT was also good, but the dose conformity was poor. The main toxicity was hematologic toxicity, without 4th-degree bone marrow suppression. There was 3rd-degree inhibition in the white blood cells, hemoglobin, and platelets. The three female patients suffered menstrual disorders during the course of radiation. Two female patients with heavy menstruation suffered 3rd-degree anemia inhibition, and 2 patients suffered amenorrhea after radiotherapy. Although menstrual cycle was normal, the third patient was not pregnant. Conclusion. CSI with HT is convenient for clinical practice, and the side effects are mild. With good conformity and uniformity, VMAT can also be used for selection in CSI. For poor conformity, 3D-CRT should not be the priority selection for CSI. In female patients, the ovaries should be protected.

  7. Risk of isolated nodal failure for non-small cell lung cancer (NSCLC) treated with the elective nodal irradiation (ENI) using 3D-conformal radiotherapy (3D-CRT) techniques - A retrospective analysis

    International Nuclear Information System (INIS)

    Kepka, Lucyna; Bujko, Krzysztof; Zolciak-Siwinska, Agnieszka

    2008-01-01

    Purpose. To estimate retrospectively the rate of isolated nodal failures (INF) in NSCLC patients treated with the elective nodal irradiation (ENI) using 3D-conformal radiotherapy (3D-CRT). Materials/methods. One hundred and eighty-five patients with I-IIIB stage treated with 3D-CRT in consecutive clinical trials differing in an extent of the ENI were analyzed. According to the extent of the ENI, two groups were distinguished: extended (n=124) and limited (n=61) ENI. INF was defined as regional nodal failure occurring without local progression. Cumulative Incidence of INF (CIINF) was evaluated by univariate and multivariate analysis with regard to prognostic factors. Results. With a median follow up of 30 months, the two-year actuarial overall survival was 35%. The two-year CIINF rate was 12%. There were 16 (9%) INF, eight (6%) for extended and eight (13%) for limited ENI. In the univariate analysis bulky mediastinal disease (BMD), left side, higher N stage, and partial response to RT had a significant negative impact on the CIINF. BMD was the only independent predictor of the risk of incidence of the INF (p=0.001). Conclusions. INF is more likely to occur in case of more advanced nodal status

  8. Postoperative Radiotherapy for Prostate Cancer: A Comparison of Four Consensus Guidelines and Dosimetric Evaluation of 3D-CRT Versus Tomotherapy IMRT

    International Nuclear Information System (INIS)

    Malone, Shawn; Croke, Jennifer; Roustan-Delatour, Nicolas; Belanger, Eric; Avruch, Leonard; Malone, Colin; Morash, Christopher; Kayser, Cathleen; Underhill, Kathryn; Li Yan; Malone, Kyle; Nyiri, Balazs; Spaans, Johanna

    2012-01-01

    Purpose: Despite the benefits of adjuvant radiotherapy after radical prostatectomy, approximately one-half of patients relapse. Four consensus guidelines have been published (European Organization for Research and Treatment of Cancer, Faculty of Radiation Oncology Genito-Urinary Group, Princess Margaret Hospital, Radiation Therapy Oncology Group) with the aim of standardizing the clinical target volume (CTV) delineation and improve outcomes. To date, no attempt has been made to compare these guidelines in terms of treatment volumes or organ at risk (OAR) irradiation. The extent to which the guideline-derived plans meet the dosimetric constraints of present trials or of the Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) trial is also unknown. Our study also explored the dosimetric benefits of intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 20 patients treated with postoperative RT were included. The three-dimensional conformal radiotherapy (3D-CRT) plans were applied to cover the guideline-generated planning target volumes (66 Gy in 33 fractions). Dose–volume histograms (DVHs) were analyzed for CTV/planning target volume coverage and to evaluate OAR irradiation. The OAR DVHs were compared with the constraints proposed in the QUANTEC and Radiotherapy and Androgen Deprivation In Combination After Local Surgery (RADICALS) trials. 3D-CRT plans were compared with the tomotherapy plans for the Radiation Therapy Oncology Group planning target volume to evaluate the advantages of IMRT. Results: The CTV differed significantly between guidelines (p < 0.001). The European Organization for Research and Treatment of Cancer-CTVs were significantly smaller than the other CTVs (p < 0.001). Differences in prostate bed coverage superiorly accounted for the major volumetric differences between the guidelines. Using 3D-CRT, the DVHs rarely met the QUANTEC or RADICALS rectal constraints, independent of the guideline used. The RADICALS

  9. Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Jackie; Suttie, Clare; Bromley, Regina; Morgia, Marita; Lamoury, Gillian [Department of Radiation Oncology, Royal North Shore Hospital, St Leonards, New South Wales (Australia)

    2015-09-15

    We report on a retrospective dosimetric study, comparing 3D conformal radiotherapy (3DCRT) and hybrid intensity modulated radiotherapy (hIMRT). We evaluated plans based on their planning target volume coverage, dose homogeneity, dose to organs at risk (OARs) and exposure of normal tissue to radiation. The Homogeneity Index (HI) was used to assess the dose homogeneity in the target region, and we describe a new index, the normal tissue index (NTI), to assess the dose in the normal tissue inside the tangent treatment portal. Plans were generated for 25 early-stage breast cancer patients, using a hIMRT technique. These were compared with the 3DCRT plans of the treatment previously received by the patients. Plan quality was evaluated using the HI, NTI and dose to OARs. The hIMRT technique was significantly more homogenous than the 3DCRT technique, while maintaining target coverage. The hIMRT technique was also superior at minimising the amount of tissue receiving D{sub 105%} and above (P < 0.0001). The ipsilateral lung and contralateral breast maximum were significantly lower in the hIMRT plans (P < 0.05 and P < 0.005), but the 3DCRT technique achieved a lower mean heart dose in left-sided breast cancer patients (P < 0.05). Hybrid intensity modulated radiotherapy plans achieved improved dose homogeneity compared to the 3DCRT plans and superior outcome with regard to dose to normal tissues. We propose that the addition of both HI and NTI in evaluating the quality of intensity modulated radiotherapy (IMRT) breast plans provides clinically relevant comparators which more accurately reflect the new paradigm of treatment goals and outcomes in the era of breast IMRT.

  10. Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index

    International Nuclear Information System (INIS)

    Yim, Jackie; Suttie, Clare; Bromley, Regina; Morgia, Marita; Lamoury, Gillian

    2015-01-01

    We report on a retrospective dosimetric study, comparing 3D conformal radiotherapy (3DCRT) and hybrid intensity modulated radiotherapy (hIMRT). We evaluated plans based on their planning target volume coverage, dose homogeneity, dose to organs at risk (OARs) and exposure of normal tissue to radiation. The Homogeneity Index (HI) was used to assess the dose homogeneity in the target region, and we describe a new index, the normal tissue index (NTI), to assess the dose in the normal tissue inside the tangent treatment portal. Plans were generated for 25 early-stage breast cancer patients, using a hIMRT technique. These were compared with the 3DCRT plans of the treatment previously received by the patients. Plan quality was evaluated using the HI, NTI and dose to OARs. The hIMRT technique was significantly more homogenous than the 3DCRT technique, while maintaining target coverage. The hIMRT technique was also superior at minimising the amount of tissue receiving D 105% and above (P < 0.0001). The ipsilateral lung and contralateral breast maximum were significantly lower in the hIMRT plans (P < 0.05 and P < 0.005), but the 3DCRT technique achieved a lower mean heart dose in left-sided breast cancer patients (P < 0.05). Hybrid intensity modulated radiotherapy plans achieved improved dose homogeneity compared to the 3DCRT plans and superior outcome with regard to dose to normal tissues. We propose that the addition of both HI and NTI in evaluating the quality of intensity modulated radiotherapy (IMRT) breast plans provides clinically relevant comparators which more accurately reflect the new paradigm of treatment goals and outcomes in the era of breast IMRT

  11. Dosimetric Comparison of Three Dimensional Conformal Radiation Radiotherapy and Helical Tomotherapy Partial Breast Cancer

    International Nuclear Information System (INIS)

    Kim, Dae Woong; Kim, Jong Won; Choi, Yun Kyeong; Kim, Jung Soo; Hwang, Jae Woong; Jeong, Kyeong Sik; Choi, Gye Suk

    2008-01-01

    The goal of radiation treatment is to deliver a prescribed radiation dose to the target volume accurately while minimizing dose to normal tissues. In this paper, we comparing the dose distribution between three dimensional conformal radiation radiotherapy (3D-CRT) and helical tomotherapy (TOMO) plan for partial breast cancer. Twenty patients were included in the study, and plans for two techniques were developed for each patient (left breast:10 patients, right breast:10 patients). For each patient 3D-CRT planning was using pinnacle planning system, inverse plan was made using Tomotherapy Hi-Art system and using the same targets and optimization goals. We comparing the Homogeneity index (HI), Conformity index (CI) and sparing of the organs at risk for dose-volume histogram. Whereas the HI, CI of TOMO was significantly better than the other, 3D-CRT was observed to have significantly poorer HI, CI. The percentage ipsilateral non-PTV breast volume that was delivered 50% of the prescribed dose was 3D-CRT (mean: 40.4%), TOMO (mean: 18.3%). The average ipsilateral lung volume percentage receiving 20% of the PD was 3D-CRT (mean: 4.8%), TOMO (mean: 14.2), concerning the average heart volume receiving 20% and 10% of the PD during treatment of left breast cancer 3D-CRT (mean: 1.6%, 3.0%), TOMO (mean: 9.7%, 26.3%) In summary, 3D-CRT and TOMO techniques were found to have acceptable PTV coverage in our study. However, in TOMO, high conformity to the PTV and effective breast tissue sparing was achieved at the expense of considerable dose exposure to the lung and heart.

  12. Dose distribution of IMRT and 3D-CRT on treating central non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Zhu Xiaoyang; Yu Guangwei

    2010-01-01

    3D-CRT and IMRT were used in the radiation therapy of Central Non-small-cell lung cancer (NSCLC), and the dose difference of the methods was estimated. Thirty-two patients suffering with II class NSCLC were selected. Based on CT images, each patient was given 1 3D-CRT (3 dimensional conformal radiotherapy) and 2 IMRT(intensity modulated radiation therapy) treatment plans (5 fields and 7 fields), respectively, and the dose distribution was evaluated too. The results showed that PTVD mean and the PTV max , PTVD max (%) and CI of IMRT were both higher than those of 3D-CRT, but the uniformity was not as good as 3D-CRT. All indexes of lung and spinal cord treated with IMRT were lower than that treated with 3D-CRT. Moreover, there was no significance of the difference between 5 fields and 7 fields. In a conclusion, IMRT could not only decrease the target dose of NSCLC, but it can protect normal tissue from radiation damage effectively. And when IMRT was used, 5 fields might be enough. (authors)

  13. Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy.

    Science.gov (United States)

    Rault, Erwann; Lacornerie, Thomas; Dang, Hong-Phuong; Crop, Frederik; Lartigau, Eric; Reynaert, Nick; Pasquier, David

    2016-02-27

    Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV

  14. Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Rault, Erwann; Lacornerie, Thomas; Dang, Hong-Phuong; Crop, Frederik; Lartigau, Eric; Reynaert, Nick; Pasquier, David

    2016-01-01

    Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV

  15. 3-D conformal radiotherapy of localized prostate cancer: A subgroup analysis of rectoscopic findings prior to radiotherapy and acute/late rectal side effects

    International Nuclear Information System (INIS)

    Goldner, Gregor; Zimmermann, Frank; Feldmann, Horst; Glocker, Stefan; Wachter-Gerstner, Natascha; Geinitz, Hans; Becker, Gerd; Poetzi, Regina; Wambersie, Andre; Bamberg, Michael; Molls, Michael; Wachter, Stefan; Poetter, Richard

    2006-01-01

    Background and purpose: To identify endoscopic pathological findings prior to radiotherapy and a possible correlation with acute or chronic rectal side effects after three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Patients and methods: Between 03/99 and 07/02, a total of 298 patients, who consented in a voluntary rectoscopy prior to radiotherapy were included into the analysis. Patients were treated with a total dose of either 70 or 74 Gy. Pathological rectoscopic findings like hemorrhoids, polyps or diverticula were documented. Acute and late rectal side effects were scored using the EORTC/RTOG score. Results: The most frequent pathological endosopic findings were hemorrhoids (35%), polyps (24%) and diverticula (13%). Rectal toxicity was mostly low to moderate. Grade 0/1 cumulative acute and late rectal side effects were 82 and 84%, grade 2 were 18 and 17%, respectively. We could not identify any correlation between preexisting pathological findings and rectal side effects by statistical analysis. Conclusions: There is no evidence that prostate cancer patients presenting with endoscopic verified pathological findings in the rectal mucosa at diagnosis are at an increased risk to develop rectal side effects when treated with 3D-CRT of the prostatic region

  16. Tolerance and early outcome results of postprostatectomy three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Aschkenasy, Eric; Kelsen, Suzanne; Leibel, Steven A.

    1997-01-01

    Purpose: Three-dimensional conformal radiotherapy (3D-CRT) has been associated with a reduction in acute and late toxicity among patients treated for localized prostatic cancer. The purpose of this study is to assess the acute and late toxicity of 3D-CRT delivered to patients in the postprostatectomy setting and to analyze which factors predict for durable biochemical control in this group of patients. Methods and Materials: Between 1988 and 1994, 42 patients were treated after prostatectomy with three-dimensional conformal radiotherapy. The median time from prostatectomy to radiotherapy was 11 months. Indications for treatment included a rising serum PSA level in 28 patients (65%) and positive surgical margins without a rising PSA level in 14 (35%). Twenty-five patients (60%) had pathologic stage T3 disease, and 32 (74%) had tumor at or close to the surgical margins. The median dose was 64.8 Gy, and the median follow-up time was 2 years. Results: 3D-CRT in the postprostatectomy setting was well tolerated. Three patients (7%) experienced Grade II acute genitourinary toxicity and nine patients (21%) experienced Grade II acute gastrointestinal toxicity during treatment. No patient experienced Grade III or higher acute morbidity. The 2-year actuarial risk for Grade II late genitourinary and gastrointestinal late complications were 5 and 9%, respectively. In patients with existing incontinence, the incidence of worsening stress incontinence 6 months after treatment was 17%, which resolved within 12 months to its preradiotherapy level in four of six cases (66%). The overall 2-year postirradiation PSA relapse-free survival rate was 53%. The 2-year PSA relapse-free survival was 66% for patients with undetectable PSA levels in the immediate postoperative period compared to 26% for those with detectable levels of PSA after surgery (p 1.0 ng/ml (p 1 ng/ml (p < 0.002) was the most important covariate predicting for a rising PSA after radiotherapy. Conclusions: After

  17. Therapeutic effect analysis of three dimensional conformal radiotherapy non-small cell lung cancer

    International Nuclear Information System (INIS)

    Yao Zhijun; Cao Yongzhen; Zhang Wenxue; Liang Feng

    2012-01-01

    Objective: To analyse the treatment effect of non-small cell lung cancer of three dimensional conformal radiotherapy (3D-CRT) and to study the effect of patient survival related factors. Methods: Retrospective analysis was mack for 136 cases of non-small cell lung cancer, all accept 3D-CRT, through the case data collection and long-term follow-up, using the single factor and multiple factor analysis survival time and its influencing factors. Results: The recent curative effects of 136 cases of patients with three dimensional conformal radiotherapy: Complete response (CR) 14.7% (20/136), partial response (PR) 60.3 (82/136), stable disease(SD) 19.9% (27/136), progression disease (PD) 5.1% (7/136), total effective rate is 75% (102/136). One, two, three, five year survival rate is 79.4%, 45.4%, 22.1%, 12.5%. Side effects: Class 1 radiated esophagitis 35 cases, Class 2 radiated esophagitis 16 cases, Class 3 and above radiated esophagitis 0 case. Class I radiated pneumonia 20 cases, Class 2 radiated pneumonia 9 cases, Class 3 radiated pneumonia 0 case. Single factor analysis shows the influence of gender, age, pathology, phase, dose, and first-phase curative effect to the survival time are of a statistical significance, Multiple factor analysis showed KPS score, phase, dose, first-phase curative effect are the survival time independent factors. Conclusion: 3D-CRT for patients with non-small cell lung carcinoma is a safe, effective treatment method, Side effects are relatively low, and the patients survival time is long after radiotherapy. (authors)

  18. Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT with 3-dimensional conformal radiation therapy (3DCRT in the hypofractionated treatment of high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Yartsev Slav

    2008-01-01

    Full Text Available Abstract Background To compare two strategies of dynamic intensity modulated radiation therapy (dIMRT with 3-dimensional conformal radiation therapy (3DCRT in the setting of hypofractionated high-risk prostate cancer treatment. Methods 3DCRT and dIMRT/Helical Tomotherapy(HT planning with 10 CT datasets was undertaken to deliver 68 Gy in 25 fractions (prostate and simultaneously delivering 45 Gy in 25 fractions (pelvic lymph node targets in a single phase. The paradigms of pelvic vessel targeting (iliac vessels with margin are used to target pelvic nodes and conformal normal tissue avoidance (treated soft tissues of the pelvis while limiting dose to identified pelvic critical structures were assessed compared to 3DCRT controls. Both dIMRT/HT and 3DCRT solutions were compared to each other using repeated measures ANOVA and post-hoc paired t-tests. Results When compared to conformal pelvic vessel targeting, conformal normal tissue avoidance delivered more homogenous PTV delivery (2/2 t-test comparisons; p dose, 1–3 Gy over 5/10 dose points; p Conclusion dIMRT/HT nodal and pelvic targeting is superior to 3DCRT in dose delivery and critical structure sparing in the setting of hypofractionation for high-risk prostate cancer. The pelvic targeting paradigm is a potential solution to deliver highly conformal pelvic radiation treatment in the setting of nodal location uncertainty in prostate cancer and other pelvic malignancies.

  19. Dosimetric Comparison Between 3DCRT and IMRT Using Different Multileaf Collimators in the Treatment of Brain Tumors

    International Nuclear Information System (INIS)

    Ding Meisong; Newman, Francis M.S.; Chen Changhu; Stuhr, Kelly; Gaspar, Laurie E.

    2009-01-01

    We investigated the differences between 3-dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT), and the impact of collimator leaf-width on IMRT plans for the treatment of nonspherical brain tumors. Eight patients treated by 3DCRT with Novalis were selected. We developed 3 IMRT plans with different multileaf collimators (Novalis m3, Varian MLC-120, and Varian MLC-80) with the same treatment margins, number of beams, and gantry positions as in the 3DCRT treatment plans. Treatment planning utilized the BrainLAB treatment planning system. For each patient, the dose constraints and optimization parameters remained identical for all plans. The heterogeneity index, the percentage target coverage, critical structures, and normal tissue volumes receiving 50% of the prescription dose were calculated to compare the dosimetric difference. Equivalent uniform dose (EUD) and tumor control probability (TCP) were also introduced to evaluate the radiobiological effect for different plans. We found that IMRT significantly improved the target dose homogeneity compared to the 3DCRT. However, IMRT showed the same radiobiological effect as 3DCRT. For the brain tumors adjacent to (or partially overlapping with) critical structures, IMRT dramatically spared the volume of the critical structures to be irradiated. In IMRT plans, the smaller collimator leaf width could reduce the volume of critical structures irradiated to the 50% level for those partially overlapping with the brain tumors. For relatively large and spherical brain tumors, the smaller collimator leaf widths give no significant benefit

  20. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC. A direct comparison of PET-based treatment planning

    International Nuclear Information System (INIS)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Ruebe, Christian

    2016-01-01

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p < 0.001; IF: 74.3 vs. 70.1 Gy, p < 0.03). With IMRT-IF, a PD of at least 66 Gy was achieved for 95 % of all plans. For IF as compared with ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p < 0.00001; 3D-CRT: 20.2 vs. 9.9 %, p < 0.00001). The esophageal NTCP showed a particularly good sparing with IMRT vs. 3D-CRT (ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels. (orig.) [de

  1. Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the hypofractionated treatment of high-risk prostate cancer

    International Nuclear Information System (INIS)

    Yuen, Jasper; Rodrigues, George; Trenka, Kristina; Coad, Terry; Yartsev, Slav; D'Souza, David; Lock, Michael; Bauman, Glenn

    2008-01-01

    To compare two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the setting of hypofractionated high-risk prostate cancer treatment. 3DCRT and dIMRT/Helical Tomotherapy(HT) planning with 10 CT datasets was undertaken to deliver 68 Gy in 25 fractions (prostate) and simultaneously delivering 45 Gy in 25 fractions (pelvic lymph node targets) in a single phase. The paradigms of pelvic vessel targeting (iliac vessels with margin are used to target pelvic nodes) and conformal normal tissue avoidance (treated soft tissues of the pelvis while limiting dose to identified pelvic critical structures) were assessed compared to 3DCRT controls. Both dIMRT/HT and 3DCRT solutions were compared to each other using repeated measures ANOVA and post-hoc paired t-tests. When compared to conformal pelvic vessel targeting, conformal normal tissue avoidance delivered more homogenous PTV delivery (2/2 t-test comparisons; p < 0.001), similar nodal coverage (8/8 t-test comparisons; p = ns), higher and more homogenous pelvic tissue dose (6/6 t-test comparisons; p < 0.03), at the cost of slightly higher critical structure dose (D dose , 1–3 Gy over 5/10 dose points; p < 0.03). The dIMRT/HT approaches were superior to 3DCRT in sparing organs at risk (22/24 t-test comparisons; p < 0.05). dIMRT/HT nodal and pelvic targeting is superior to 3DCRT in dose delivery and critical structure sparing in the setting of hypofractionation for high-risk prostate cancer. The pelvic targeting paradigm is a potential solution to deliver highly conformal pelvic radiation treatment in the setting of nodal location uncertainty in prostate cancer and other pelvic malignancies

  2. Intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy for high-grade gliomas: Does IMRT increase the integral dose to normal brain?

    International Nuclear Information System (INIS)

    Hermanto, Ulrich; Frija, Erik K.; Lii, MingFwu J.; Chang, Eric L.; Mahajan, Anita; Woo, Shiao Y.

    2007-01-01

    Purpose: To determine whether intensity-modulated radiotherapy (IMRT) treatment increases the total integral dose of nontarget tissue relative to the conventional three-dimensional conformal radiotherapy (3D-CRT) technique for high-grade gliomas. Methods and Materials: Twenty patients treated with 3D-CRT for glioblastoma multiforme were selected for a comparative dosimetric evaluation with IMRT. Original target volumes, organs at risk (OAR), and dose-volume constraints were used for replanning with IMRT. Predicted isodose distributions, cumulative dose-volume histograms of target volumes and OAR, normal tissue integral dose, target coverage, dose conformity, and normal tissue sparing with 3D-CRT and IMRT planning were compared. Statistical analyses were performed to determine differences. Results: In all 20 patients, IMRT maintained equivalent target coverage, improved target conformity (conformity index [CI] 95% 1.52 vs. 1.38, p mean by 19.8% and D max by 10.7%), optic chiasm (D mean by 25.3% and D max by 22.6%), right optic nerve (D mean by 37.3% and D max by 28.5%), and left optic nerve (D mean by 40.6% and D max by 36.7%), p ≤ 0.01. This was achieved without increasing the total nontarget integral dose by greater than 0.5%. Overall, total integral dose was reduced by 7-10% with IMRT, p < 0.001, without significantly increasing the 0.5-5 Gy low-dose volume. Conclusions: These results indicate that IMRT treatment for high-grade gliomas allows for improved target conformity, better critical tissue sparing, and importantly does so without increasing integral dose and the volume of normal tissue exposed to low doses of radiation

  3. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC: A direct comparison of PET-based treatment planning.

    Science.gov (United States)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Rübe, Christian

    2016-02-01

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels.

  4. Parotid gland sparing radiotherapy technique using 3-D conformal radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lim, Ji Hoon; Kim, Gwi Eon; Keum, Ki Chang; Suh, Chang Ok; Lee, Sang Wook; Park, Hee Chul; Cho, Jae Ho; Chang, Sei Kyung; Loh, Juhn Kyu

    2000-01-01

    Although using the high energy photon beam with conventional parallel-opposed beams radio-therapy for nasopgaryngeal carcinoma, radiation-induced xerostomia is a troublesome problem for patients. We conducted this study to explore a new parotid gland sparing technique in 3-D conformal radiotherapy (3-DCRT) in an effort to prevent the radiation-induced xerostomia. We performed three different planning for four clinically node-negative nasopharyngeal cancer patients with different location of tumor(intracranial extension, nasal cavity extension, oropharyngeal extension, parapharyngeal extension), and intercompared the plans. Total prescription dose was 70.2 Gy to the isocenter. For plan-A, 2-D parallel opposing fields, a conventional radiotherapy technique, were employed. For plan-B, 2-D parallel opposing fields were used up until 54 Gy and afterwards 3-D non-coplanar beams were used. For plan-C, the new technique, 54Gy was delivered by 3-D conformal 3-port beams (AP and both lateral ports with wedge compensator, shielding both superficial lobes of parotid glands at the AP beam using BEV) from the beginning of the treatment and early spinal cord block (at 36 Gy) was performed. And bilateral posterior necks were treated with electron after 36 Gy. After 54 Gy, non-coplanar beams were used for cone-down plan. We intercompared dose statistics (Dmax, Dmin, Dmean, D95, D05, V95, V05, Volume receiving 46 Gy) and dose volume histograms (DVH) of tumor and normal tissues and NTCP values of parotid glands for the above three plans. For all patients, the new technique (plan-C) was comparable or superior to the other plans in target volume isodose distribution and dose statistics and it has more homogenous target volume coverage. The new technique was most superior to the other plans in parotid glands sparing (volume receiving 46 Gy: 100, 98, 69% for each plan-A, B and C). And it showed the lowest NTCP value of parotid glands in all patients (range of NTCP; 96-100%, 79-99%, 51

  5. A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

    Directory of Open Access Journals (Sweden)

    Foroudi Farshad

    2012-07-01

    Full Text Available Abstract Background To compare 3 Dimensional Conformal radiotherapy (3D-CRT with Intensity Modulated Radiotherapy (IMRT with Volumetric-Modulated Arc Therapy (VMAT for bladder cancer. Methods Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. Results Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293 for 3D-CRT; 824 (range 641–1083 for IMRT; and 403 (range 333–489 for VMAT (P  Conclusions VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours.

  6. A comparative dosimetric study of conventional, conformal and intensity-modulated radiotherapy in postoperative pelvic irradiation of cervical cancer

    International Nuclear Information System (INIS)

    Li Bin; An Jusheng; Wu Lingying; Huang Manni; Gao Juzhen; Xu Yingjie; Dai Jianrong

    2008-01-01

    Objective: To evaluate target-volume coverage and organ at risk (OAR) protection achieved with conventional radiotherapy (CRT), three dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy(IMRT) through dosimetric comparison in patients with cervical cancer after hysterectomy. Methods: The planning CT scans of 10 patients treated with pelvic radiation after hysterectomy for cervical cancer were used to generate CRT, 3DCRT and IMRT plans for this study. Clinical target volume(CTV) was contoured on the individual axial CT slices of every patient. The CTV was then uniformly expanded by 1.0 cm to create the planning target volume (PTV). The small bowel, rectum, bladder, bone marrow, ovaries, and femoral heads were outlined for the organ at risk (OAR) evaluation. The CRT, 3DCRT and IMRT plans were generated using commercial planning software. CRT plan was prescribed to deliver 45 Gy to the reference point, while IMRT and 3DCRT plans were 45 Gy to 95% of the PTV. Isodose line and dose volume histograms(DVH) were used to evaluate the dose distribution in CTV and OAR. Results: For 10 patients, the average volume of CTV receiving the prescribed dose of CRT was significantly lower than 3DCRT(Q=8.27, P<0.01) and IMRT(Q=8.37, P<0.01), respectively. Comparing with the CRT plan, the 3DCRT and IMRT plans notably reduced the volume of bowel at 30 and 45 Gy levels. The IMRT plan significantly spared rectum and bladder at 30 and 45 Gy levels comparing with the CRT (P<0.01) and 3DCRT(P<0.05) plans, while the 3DCRT plan significantly spared rectum and bladder at 45 Gy level comparing with the CRT(P<0.01) plans. For 4 patients with ovarian transposition, the average doses of ovary over 3 Gy were 2 patients with the 3 DCRT and IMRT plans, and 2 with all three plans. Conclusions: IMRT and 3DCRT are superior to CRT in improving dose coverage of target volume and sparing of OAR, while IMRT being the best. The superiority of IMRT and 3DCRT is obvious in sparing

  7. Assessment of renal function after conformal radiotherapy and intensity-modulated radiotherapy by functional 1H-MRI and 23Na-MRI

    International Nuclear Information System (INIS)

    Haneder, S.; Michaely, H.J.; Schoenberg, S.O.; Konstandin, S.; Schad, L.R.; Siebenlist, K.; Wertz, H.; Wenz, F.; Lohr, F.; Boda-Heggemann, J.

    2012-01-01

    Purpose: Adjuvant radiochemotherapy (RCHT) improves survival of patients with locally advanced gastric cancer. Conventional three-dimensional conformal radiotherapy (3D-CRT) results in ablative doses to a significant amount of the left kidney, while image-guided intensity-modulated radiotherapy (IG-IMRT) provides excellent target coverage with improved kidney sparing. Few long-term results on IMRT for gastric cancer, however, have been published. Functional magnetic resonance imaging (fMRI) at 3.0 T including blood oxygenation-level dependent (BOLD) imaging, diffusion-weighted imaging (DWI) and, for the first time, 23 Na imaging was used to evaluate renal status after radiotherapy with 3D-CRT or IG-IMRT. Patients and methods Four disease-free patients (2 after 3D-CRT and 2 after IMRT; FU for all patients > 5 years) were included in this feasibility study. Morphological sequences, axial DWI images, 2D-gradient echo (GRE)-BOLD images, and 23 Na images were acquired. Mean values/standard deviations for ( 23 Na), the apparent diffusion coefficient (ADC), and R2 * values were calculated for the upper/middle/lower parts of both kidneys. Corticomedullary 23 Na-concentration gradients were determined. Results: Surprisingly, IG-IMRT patients showed no morphological alterations and no statistically significant differences of ADC and R2 * values in all renal parts. Values for mean corticomedullary 23 Na-concentration matched those for healthy volunteers. Results were similar in 3D-CRT patients, except for the cranial part of the left kidney. This was atrophic and presented significantly reduced functional parameters (p = 0.001 - p = 0.033). Reduced ADC values indicated reduced cell density and reduced extracellular space. Cortical and medullary R2 * values of the left cranial kidney in the 3D-CRT group were higher, indicating more deoxygenated hemoglobin due to reduced blood flow/oxygenation. ( 23 Na) of the renal cranial parts in the 3D-CRT group was significantly reduced

  8. Biological Modeling Based Outcome Analysis (BMOA) in 3D Conformal Radiation Therapy (3DCRT) Treatments for Lung and Breast Cancers

    Science.gov (United States)

    Pyakuryal, Anil; Chen, Chiu-Hao; Dhungana, Sudarshan

    2010-03-01

    3DCRT treatments are the most commonly used techniques in the treatment of lung and breast cancers. The purpose of this study was to perform the BMOA of the 3DCRT plans designed for the treatment of breast and lung cancers utilizing HART program (Med. Phys. 36, p.2547(2009)). The BMOA parameters include normal tissue complication probability (NTCP), tumor control probability (TCP), and the complication-free tumor control probability (P+). The 3DCRT plans were designed for (i) the palliative treatment of 8 left lung cancer patients (CPs) at early stage (m=8), (ii) the curative treatment of 8 left lung CPs at stages II and III (k=8), and (iii) the curative treatment of 8 left breast CPs (n=8). The NTCPs were noticeably small (esophagus in lung CPs (k=8). Assessments of the TCPs and P+s also indicated good improvements in local tumor control in all plans. Homogeneous target coverage and improved dose conformality were the major advantages of such techniques in the treatment of breast cancer. These achievements support the efficacy of the 3DCRT techniques for the efficient treatment of various types of cancer.

  9. Three-year outcomes of a once daily fractionation scheme for accelerated partial breast irradiation (APBI) using 3-D conformal radiotherapy (3D-CRT)

    International Nuclear Information System (INIS)

    Goyal, Sharad; Daroui, Parima; Khan, Atif J; Kearney, Thomas; Kirstein, Laurie; Haffty, Bruce G

    2013-01-01

    The aim of this study was to report 3-year outcomes of toxicity, cosmesis, and local control using a once daily fractionation scheme (49.95 Gy in 3.33 Gy once daily fractions) for accelerated partial breast irradiation (APBI) using three-dimensional conformal radiotherapy (3D-CRT). Between July 2008 and August 2010, women aged ≥40 years with ductal carcinoma in situ or node-negative invasive breast cancer ≤3 cm in diameter, treated with breast-conserving surgery achieving negative margins, were accrued to a prospective study. Women were treated with APBI using 3–5 photon beams, delivering 49.95 Gy over 15 once daily fractions over 3 weeks. Patients were assessed for toxicities, cosmesis, and local control rates before APBI and at specified time points. Thirty-four patients (mean age 60 years) with Tis 0 (n = 9) and T1N0 (n = 25) breast cancer were treated and followed up for an average of 39 months. Only 3% (1/34) patients experienced a grade 3 subcutaneous fibrosis and breast edema and 97% of the patients had good/excellent cosmetic outcome at 3 years. The 3-year rate of ipsilateral breast tumor recurrence (IBTR) was 0% while the rate of contralateral breast events was 6%. The 3-year disease-free survival (DFS), overall survival (OS), and breast cancer-specific survival (BCSS) was 94%, 100%, and 100%, respectively. Our novel accelerated partial breast fractionation scheme of 15 once daily fractions of 3.33 Gy (49.95 Gy total) is a remarkably well-tolerated regimen of 3D-CRT-based APBI. A larger cohort of patients is needed to further ascertain the toxicity of this accelerated partial breast regimen

  10. Conkiss: Conformal Kidneys Sparing 3D Noncoplanar Radiotherapy Treatment for Pancreatic Cancer As an Alternative to IMRT

    International Nuclear Information System (INIS)

    Sebestyen, Zsolt; Kovacs, Peter; Gulyban, Akos; Farkas, Robert; Bellyei, Szabolcs; Liposits, Gabor; Szigeti, Andras; Esik, Olga; Derczy, Katalin; Mangel, Laszlo

    2011-01-01

    When treating pancreatic cancer using standard (ST) 3D conformal radiotherapy (3D-CRT) beam arrangements, the kidneys often receive a higher dose than their probable tolerance limit. Our aim was to elaborate a new planning method that-similarly to IMRT-effectively spares the kidneys without compromising the target coverage. Conformal kidneys sparing (CONKISS) 5-field, noncoplanar plans were compared with ST plans for 23 consecutive patients retrospectively. Optimal beam arrangements were used consisting of a left- and right-wedged beam-pair and an anteroposterior beam inclined in the caudal direction. The wedge direction determination (WEDDE) algorithm was developed to adjust the adequate direction of wedges. The aimed organs at risk (OARs) mean dose limits were: kidney <12 Gy, liver <25 Gy, small bowels <30 Gy, and spinal cord maximum <45 Gy. Conformity and homogeneity indexes with z-test were used to evaluate and compare the different planning approaches. The mean dose to the kidneys decreased significantly (p < 0.05): left kidney 7.7 vs. 10.7 Gy, right kidney 9.1 vs. 11.7 Gy. Meanwhile the mean dose to the liver increased significantly (18.1 vs. 15.0 Gy). The changes in the conformity, homogeneity, and in the doses to other OARs were not significant. The CONKISS method balances the load among the OARs and significantly reduces the dose to the kidneys, without any significant change in the conformity and homogeneity. Using 3D-CRT the CONKISS method can be a smart alternative to IMRT to enhance the possibility of dose escalation.

  11. A comparison of swallowing dysfunction after three-dimensional conformal and intensity-modulated radiotherapy. A systematic review by the Italian Head and Neck Radiotherapy Study Group

    International Nuclear Information System (INIS)

    Ursino, Stefano; Morganti, Riccardo; Cristaudo, Agostino; Paiar, Fabiola; D'Angelo, Elisa; Lohr, Frank; Mazzola, Rosario; Merlotti, Anna; Russi, Elvio Grazioso; Musio, Daniela; Alterio, Daniela; Bacigalupo, Almalina

    2017-01-01

    Dysphagia is one of the most important treatment-related side effects in head and neck cancer (HNC), as it can lead to severe life-threating complications such as aspiration pneumonia and malnutrition. Intensity-modulated radiotherapy (IMRT) could reduce swallowing dysfunction by producing a concave dose distribution and reducing doses to the swallowing-related organs at risk (SWOARs). The aim of this study was to review the current literature in order to compare swallowing outcomes between IMRT and three-dimensional conformal radiotherapy (3DCRT). A search was conducted in the PubMed and Embase databases to identify studies on swallowing outcomes, both clinically and/or instrumentally assessed, after 3DCRT and IMRT. Dysphagia-specific quality of life and objective instrumental data are summarized and discussed. A total of 262 papers were retrieved from the searched databases. An additional 23 papers were retrieved by hand-searching the reference lists. Ultimately, 22 papers were identified which discussed swallowing outcomes after 3DCRT and IMRT for HNC. No outcomes from randomized trials were identified. Despite several methodological limitations, reports from the current literature seem to suggest better swallowing outcomes with IMRT compared to 3DCRT. Further improvements are likely to result from the increased use of IMRT plans optimized for SWOAR sparing. (orig.) [de

  12. Comparing morbidity and cancer control after 3D-conformal (70/74 Gy) and intensity modulated radiotherapy (78/82 Gy) for prostate cancer

    International Nuclear Information System (INIS)

    Dolezel, Martin; Odrazka, Karel; Zouhar, Milan; Jansa, Jan; Paluska, Petr; Vaculikova, Miloslava; Sefrova, Jana; Kohlova, Tereza; Vanasek, Jaroslav; Kovarik, Josef

    2015-01-01

    The purpose of this work was to compare toxicity and cancer control between patients with prostate cancer treated using three-dimensional conformal radiotherapy (3D-CRT) and those treated using intensity-modulated radiation therapy (IMRT). A total of 553 patients with prostate cancer were treated with 3D-CRT 70-74 Gy (3D-CRT 70, 3D-CRT 74) or IMRT 78-82 Gy (IMRT 78, IMRT/SIB 82). Late toxicity was scored according to FC-RTOG/LENT criteria. Biochemical failure was defined using the Phoenix and ASTRO definitions. The 5-year risk of grade 2-4 genitourinary toxicity was 26.3 % (3D-CRT 70), 27.2 % (3D-CRT 74), 17.3 % (IMRT 78), and 25.1 % (IMRT/SIB 82) without statistical differences. The 5-year risk of grade 2-4 gastrointestinal toxicity was 19.4 % (3D-CRT 70), 42.1 % (3D-CRT 74), 20.5 % (IMRT 78), and 26.6 % (IMRT/SIB 82). The differences between 3D-CRT 74 and 3D-CRT 70 and between 3D-CRT 74 and IMRT 78 were statistically significant (log rank p = 0.03). The 5-year Phoenix PSA relapse-free survival (PSA-RFS) in low-risk, intermediate-risk, and high-risk patients treated using 3D-CRT were 89.4, 65.5, and 57.8 %, respectively. Patients treated with IMRT achieved the following results: 90.9, 89.4, and 83.9 %. Clinical relapse-free survival (C-RFS) in patients treated using 3D-CRT vs. IMRT for the aforementioned groups were 94.7 vs. 100 %, 86.8 vs. 98.6 %, and 84.4 vs. 94.5 %. Disease-free survival (DFS) for patients treated using 3D-CRT were 83.1, 70.9, and 71.5 %. The IMRT group reached 95.8, 89.1, and 87.6 %. The PSA-RFS for intermediate- and high-risk patients were statistically significant, while C-RFS and DFS were marginally better. Dose escalation with IMRT was associated with improved cancer control in intermediate- and high-risk patients in comparison with 3D-CRT, without compromising toxicity. (orig.) [de

  13. External validation of three dimensional conformal radiotherapy based NTCP models for patient-rated xerostomia and sticky saliva among patients treated with intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Beetz, Ivo; Schilstra, Cornelis; Luijk, Peter van; Christianen, Miranda E.M.C.; Doornaert, Patricia; Bijl, Henk P.; Chouvalova, Olga; Heuvel, Edwin R. van den; Steenbakkers, Roel J.H.M.; Langendijk, Johannes A.

    2012-01-01

    Purpose: The purpose of this study was to investigate the ability of predictive models for patient-rated xerostomia (XER 6M ) and sticky saliva (STIC 6M ) at 6 months after completion of primary (chemo)radiation developed in head and neck cancer patients treated with 3D-conformal radiotherapy (3D-CRT) to predict outcome in patients treated with intensity modulated radiotherapy (IMRT). Methods and materials: Recently, we published the results of a prospective study on predictive models for patient-rated xerostomia and sticky saliva in head and neck cancer patients treated with 3D-CRT (3D-CRT based NTCP models). The 3D-CRT based model for XER 6M consisted of three factors, including the mean parotid dose, age, and baseline xerostomia (none versus a bit). The 3D-CRT based model for STIC 6M consisted of the mean submandibular dose, age, the mean sublingual dose, and baseline sticky saliva (none versus a bit). In the current study, a population consisting of 162 patients treated with IMRT was used to test the external validity of these 3D-CRT based models. External validity was described by the explained variation (R 2 Nagelkerke) and the Brier score. The discriminative abilities of the models were calculated using the area under the receiver operating curve (AUC) and calibration (i.e. the agreement between predicted and observed outcome) was assessed with the Hosmer–Lemeshow “goodness-of-fit” test. Results: Overall model performance of the 3D-CRT based predictive models for XER 6M and STIC 6M was significantly worse in terms of the Brier score and R 2 Nagelkerke among patients treated with IMRT. Moreover the AUC for both 3D-CRT based models in the IMRT treated patients were markedly lower. The Hosmer–Lemeshow test showed a significant disagreement for both models between predicted risk and observed outcome. Conclusion: 3D-CRT based models for patient-rated xerostomia and sticky saliva among head and neck cancer patients treated with primary radiotherapy or

  14. Preliminary results of three-dimensional conformal radiotherapy for non-small cell lung cancer

    International Nuclear Information System (INIS)

    Wang Yingjie; Wang Luhua; Wang Xin; Feng Qinfu; Zhang Hongxing; Xiao Zefen; Yin Weibo

    2005-01-01

    Objective: To evaluate the therapeutic effects and complications of three-dimensional conformal radiotherapy (3DCRT) for non-small cell lung cancer (NSCLC). Methods: Between March 1999 and September 2003, 91 NSCLC patients treated with 3DCRT were reviewed at the Cancer Hospital, Chinese Academy of Medical Sciences. This patient cohort consisted of 73 men and 18 women. The median age was 66 years. Radio-therapy was delivered at 2 Gy fraction, 5 fractions per week. The median total dose was 60 Gy. Results: With a median follow-up time of 17 months, the response rate after 3DCRT was 57.1%, with complete remission 11.0% (10/91) and partial remission 46.2%(42/91). The median survival time (MST) was 16 months, with 1- and 2- year overall survivals (OS) of 67.0% and 32.6%, 1- and 2-year local progression free survivals (LPFS) of 82.6% and 53.0%, respectively. The independent adverse prognostic factors by univariate analysis and multivariate analysis was weight loss ≥5%. Grade 2 acute radiation pneumonitis was observed in 2 patients and grade 3 in 4 patients. Late lung injury developed in 1 patient with grade 2, 1 patient with grade 3, respectively. Acute radiation esophagitis was observed in 8 patients with grade 2. Acute grade 2 hematologic toxicity developed in 5 patients. Conclusions: 3DCRT was feasible in the treatment of NSCLC with good immediate tumor response and acceptable normal tissue complication. The total dose may potentially be increased. (authors)

  15. Intensity-Modulated Radiotherapy Causes Fewer Side Effects than Three-Dimensional Conformal Radiotherapy When Used in Combination With Brachytherapy for the Treatment of Prostate Cancer

    International Nuclear Information System (INIS)

    Forsythe, Kevin; Blacksburg, Seth; Stone, Nelson; Stock, Richard G.

    2012-01-01

    Purpose: To measure the benefits of intensity-modulated radiotherapy (IMRT) compared with three-dimensional conformal radiotherapy (3D-CRT) when used in combination with brachytherapy for the treatment of prostate cancer. Methods and Materials: We conducted a retrospective review of all patients with localized prostate cancer who received external-beam radiotherapy (EBRT) in combination with brachytherapy with at least 1 year follow-up (n = 812). Combination therapy consisted of 103 Pd or 125 I implant, followed by a course of EBRT. From 1993 to March 2003 521 patients were treated with 3D-CRT, and from April 2003 to March 2009 291 patients were treated with IMRT. Urinary symptoms were prospectively measured with the International Prostate Symptom Score questionnaire with a single quality of life (QOL) question; rectal bleeding was assessed per the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Radiation Morbidity Scoring Schema. The Pearson χ 2 test was used to compare toxicities experienced by patients who were treated with either IMRT or 3D-CRT. Logistic regression analyses were also performed to rule out possible confounding factors. Results: Within the first 3 months after treatment, patients treated with 3D-CRT scored their urinary symptoms as follows: 19% mild, 44% moderate, and 37% severe; patients treated with IMRT scored their urinary symptoms as follows: 36% mild, 47% moderate, and 17% severe (p < 0.001). The 3D-CRT patients rated their QOL as follows: 35% positive, 20% neutral, and 45% negative; IMRT patients rated their QOL as follows: 51% positive, 18% neutral, and 31% negative (p < 0.001). After 1 year of follow-up there was no longer any difference in urinary morbidity between the two groups. Logistic regression confirmed the differences in International Prostate Symptom Score and QOL in the acute setting (p < 0.001 for both). Grade ≥2 rectal bleeding was reported by 11% of 3D-CRT patients and 7

  16. A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

    International Nuclear Information System (INIS)

    Foroudi, Farshad; Kron, Tomas; Wilson, Lesley; Bressel, Mathias; Haworth, Annette; Hornby, Colin; Pham, Daniel; Cramb, Jim; Gill, Suki; Tai, Keen Hun

    2012-01-01

    To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB) of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI) index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI) index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293) for 3D-CRT; 824 (range 641–1083) for IMRT; and 403 (range 333–489) for VMAT (P < 0.05). Average treatment delivery time were 2:25min (range 2:01–3:09) for 3D-CRT; 4:39 (range 3:41–6:40) for IMRT; and 1:14 (range 1:13–1:14) for VMAT. In selected patients, the SIB did not result in a higher dose to small bowel or rectum. VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours

  17. 3DCRT for posterior fossa: Sparing of surrounding organs at risk ...

    African Journals Online (AJOL)

    Introduction: Radiotherapy of the posterior fossa is routinely delivered using 3DCRT parallel-opposed lateral fields. However high incidence of sensorineural hearing loss, hypothalamic– pituitary dysfunction, thyroid and gonadal dysfunction during radiotherapy makes the need for treatment plan which provides adequate ...

  18. Dosimetric comparison of 3DCRT versus IMRT in whole breast irradiation of early stage breast cancer

    Directory of Open Access Journals (Sweden)

    Mudasir Ashraf

    2014-08-01

    Full Text Available Purpose: The counseling regarding the treatment option is an important objective in the management of early stages breast cancer. In this study, we attempt to compare and analyze the dosimetric aspects of 3DRT over IMRT in the whole breast radiotherapy.Methods and Materials:  Both right and left sided computed tomography simulations of 14 women with early stage breast cancer were used for our retrospective study to compare the 3DCRT and IMRT. The dose prescribed was 50 Gy in 25 fractions to the whole breast PTV. The PTV was defined by adding unequal margins to the directional safety margin status of each lumpectomy cavity (i.e., medial, lateral, superior, inferior and deep margins measured from the tumor front after the examination of the surgical specimen: 2, 1.5, and 1 cm for resection margins < 1 cm, 1-2 cm, and > 2cm, respectively. And than modified so that it was no longer closer than 3mm to the skin surface and was no deep than the lung –chest interface. The prescribed dose delivered in 5 fractions per week schedule. Treatment plans were compared for target minimum dose, maximum dose, mean dose, conformity index, heterogeneity index and doses to organs at risk were compared and analysed.Results: The target coverage was achieved with 90% prescription to the 95% of the PTV. Conformity to the PTV was significantly higher with 3DCRT technique than IMRT. 3DCRT technique seems better in sparing critical organs parameters like lung V20 and Mean, heart, V25, Maximum, both lungs V20, Mean and Dose to the Normal Healthy tissue.Conclusion: We conclude from our study that treatment technique selection for whole Breast irradiation is an important factor in sparing the adjacent normal structures and in determining the associated risk. 3DCRT produces better conformity and heterogeneity indices of the target volume, also reduces dose to OARs the 3DCRT reduces the risk of radiation induced heart diseases

  19. Assessment of renal function after conformal radiotherapy and intensity-modulated radiotherapy by functional {sup 1}H-MRI and {sup 23}Na-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Haneder, S.; Michaely, H.J.; Schoenberg, S.O. [Universitaetsmedizin Mannheim, Heidelberg Univ., Mannheim (Germany). Inst. of Clinical Radiology and Nuclear Medicine; Konstandin, S.; Schad, L.R. [Universitaetsmedizin Mannheim, Heidelberg Univ., Mannheim (Germany). Computer-Assisted Clinical Medicine; Siebenlist, K.; Wertz, H.; Wenz, F.; Lohr, F.; Boda-Heggemann, J. [Universitaetsmedizin Mannheim, Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology

    2012-12-15

    Purpose: Adjuvant radiochemotherapy (RCHT) improves survival of patients with locally advanced gastric cancer. Conventional three-dimensional conformal radiotherapy (3D-CRT) results in ablative doses to a significant amount of the left kidney, while image-guided intensity-modulated radiotherapy (IG-IMRT) provides excellent target coverage with improved kidney sparing. Few long-term results on IMRT for gastric cancer, however, have been published. Functional magnetic resonance imaging (fMRI) at 3.0 T including blood oxygenation-level dependent (BOLD) imaging, diffusion-weighted imaging (DWI) and, for the first time, {sup 23}Na imaging was used to evaluate renal status after radiotherapy with 3D-CRT or IG-IMRT. Patients and methods Four disease-free patients (2 after 3D-CRT and 2 after IMRT; FU for all patients > 5 years) were included in this feasibility study. Morphological sequences, axial DWI images, 2D-gradient echo (GRE)-BOLD images, and {sup 23}Na images were acquired. Mean values/standard deviations for ({sup 23}Na), the apparent diffusion coefficient (ADC), and R2{sup *} values were calculated for the upper/middle/lower parts of both kidneys. Corticomedullary {sup 23}Na-concentration gradients were determined. Results: Surprisingly, IG-IMRT patients showed no morphological alterations and no statistically significant differences of ADC and R2{sup *} values in all renal parts. Values for mean corticomedullary {sup 23}Na-concentration matched those for healthy volunteers. Results were similar in 3D-CRT patients, except for the cranial part of the left kidney. This was atrophic and presented significantly reduced functional parameters (p = 0.001 - p = 0.033). Reduced ADC values indicated reduced cell density and reduced extracellular space. Cortical and medullary R2{sup *} values of the left cranial kidney in the 3D-CRT group were higher, indicating more deoxygenated hemoglobin due to reduced blood flow/oxygenation. ({sup 23}Na) of the renal cranial parts in

  20. Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment

    Directory of Open Access Journals (Sweden)

    Bora Uysal

    2013-03-01

    Full Text Available Objective: The purpose of this dosimetric study is the targeted dose homogeneity and critical organ dose comparison of 7-field Intensity Modulated Radiotherapy (IMRT and 3-D 4-field conformal radiotherapy. Study Design: Cross sectional study. Material and Methods: Twenty patients with low and moderate risk prostate cancer treated at Gülhane Military Medical School Radiation Oncology Department between January 2009 and December 2009 are included in this study. Two seperate dosimetric plans both for 7-field IMRT and 3D-CRT have been generated for each patient to comparatively evaluate the dosimetric status of both techniques and all the patients received 7-field IMRT. Results: Dose-comparative evaluation of two techniques revealed the superiority of IMRT technique with statistically significantly lower femoral head doses along with reduced critical organ dose-volume parameters of bladder V60 (the volume receiving 60 Gy and rectal V40 (the volume receiving 40 Gy and V60. Conclusion: It can be concluded that IMRT is an effective definitive management tool for prostate cancer with improved critical organ sparing and excellent dose homogenization in target organs of prostate and seminal vesicles.

  1. Toxicity and dosimetric analysis of non-small cell lung cancer patients undergoing radiotherapy with 4DCT and image-guided intensity modulated radiotherapy: a regional centre's experience.

    Science.gov (United States)

    Livingston, Gareth C; Last, Andrew J; Shakespeare, Thomas P; Dwyer, Patrick M; Westhuyzen, Justin; McKay, Michael J; Connors, Lisa; Leader, Stephanie; Greenham, Stuart

    2016-09-01

    For patients receiving radiotherapy for locally advance non-small cell lung cancer (NSCLC), the probability of experiencing severe radiation pneumonitis (RP) appears to rise with an increase in radiation received by the lungs. Intensity modulated radiotherapy (IMRT) provides the ability to reduce planned doses to healthy organs at risk (OAR) and can potentially reduce treatment-related side effects. This study reports toxicity outcomes and provides a dosimetric comparison with three-dimensional conformal radiotherapy (3DCRT). Thirty curative NSCLC patients received radiotherapy using four-dimensional computed tomography and five-field IMRT. All were assessed for early and late toxicity using common terminology criteria for adverse events. All plans were subsequently re-planned using 3DCRT to the same standard as the clinical plans. Dosimetric parameters for lungs, oesophagus, heart and conformity were recorded for comparison between the two techniques. IMRT plans achieved improved high-dose conformity and reduced OAR doses including lung volumes irradiated to 5-20 Gy. One case each of oesophagitis and erythema (3%) were the only Grade 3 toxicities. Rates of Grade 2 oesophagitis were 40%. No cases of Grade 3 RP were recorded and Grade 2 RP rates were as low as 3%. IMRT provides a dosimetric benefit when compared to 3DCRT. While the clinical benefit appears to increase with increasing target size and increasing complexity, IMRT appears preferential to 3DCRT in the treatment of NSCLC.

  2. Integral Dose and Radiation-Induced Secondary Malignancies: Comparison between Stereotactic Body Radiation Therapy and Three-Dimensional Conformal Radiotherapy

    Directory of Open Access Journals (Sweden)

    Stefano G. Masciullo

    2012-11-01

    Full Text Available The aim of the present paper is to compare the integral dose received by non-tumor tissue (NTID in stereotactic body radiation therapy (SBRT with modified LINAC with that received by three-dimensional conformal radiotherapy (3D-CRT, estimating possible correlations between NTID and radiation-induced secondary malignancy risk. Eight patients with intrathoracic lesions were treated with SBRT, 23 Gy × 1 fraction. All patients were then replanned for 3D-CRT, maintaining the same target coverage and applying a dose scheme of 2 Gy × 32 fractions. The dose equivalence between the different treatment modalities was achieved assuming α/β = 10Gy for tumor tissue and imposing the same biological effective dose (BED on the target (BED = 76Gy10. Total NTIDs for both techniques was calculated considering α/β = 3Gy for healthy tissue. Excess absolute cancer risk (EAR was calculated for various organs using a mechanistic model that includes fractionation effects. A paired two-tailed Student t-test was performed to determine statistically significant differences between the data (p ≤ 0.05. Our study indicates that despite the fact that for all patients integral dose is higher for SBRT treatments than 3D-CRT (p = 0.002, secondary cancer risk associated to SBRT patients is significantly smaller than that calculated for 3D-CRT (p = 0.001. This suggests that integral dose is not a good estimator for quantifying cancer induction. Indeed, for the model and parameters used, hypofractionated radiotherapy has the potential for secondary cancer reduction. The development of reliable secondary cancer risk models seems to be a key issue in fractionated radiotherapy. Further assessments of integral doses received with 3D-CRT and other special techniques are also strongly encouraged.

  3. Heart dose reduction in breast cancer treatment with simultaneous integrated boost. Comparison of treatment planning and dosimetry for a novel hybrid technique and 3D-CRT

    International Nuclear Information System (INIS)

    Joest, Vincent; Kretschmer, Matthias; Sabatino, Marcello; Wuerschmidt, Florian; Dahle, Joerg; Lorenzen, Joern; Ueberle, Friedrich

    2015-01-01

    The present study compares in silico treatment plans of clinically established three-dimensional conformal radiotherapy (3D-CRT) with a hybrid technique consisting of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) during normally fractionated radiation of mammary carcinomas with simultaneous integrated boost on the basis of dose-volume histogram (DVH) parameters. Radiation treatment planning was performed with a hybrid and a 3D-CRT treatment plan for 20 patients. Hybrid plans were implemented with two tangential IMRT fields and a VMAT field in the angular range of the tangents. Verification of the plan was performed with a manufacturer-independent measurement system consisting of a detector array and rotation unit. The mean values of the heart dose for the entire patient collective were 3.6 ± 2.5 Gy for 3D-CRT and 2.9 ± 2.1 Gy for the hybrid technique (p < 0.01). For the left side (n = 10), the mean values for the left anterior descending artery were 21.8 ± 7.4 Gy for 3D-CRT and 17.6 ± 7.4 Gy for the hybrid technique (p < 0.01). The mean values of the ipsilateral lung were 11.9 ± 1.6 Gy for 3D-CRT and 10.5 ± 1.3 Gy for the hybrid technique (p < 0.01). Calculated dose distributions in the hybrid arm were in good accordance with measured dose (on average 95.6 ± 0.5 % for γ < 1 and 3 %/3 mm). The difference of the mean treatment time per fraction was 7 s in favor of 3D-CRT. Compared with the established 3D-CRT technique, the hybrid technique allows for a decrease in dose, particularly of the mean heart and lung dose with comparable target volume acquisition and without disadvantageous low-dose load of contralateral structures. Uncomplicated implementation of the hybrid technique was demonstrated in this context. The hybrid technique combines the advantages of tangential IMRT with the superior sparing of organs at risk by VMAT. (orig.) [de

  4. Strategies to evaluate the impact of rectal volume on prostate motion during three-dimensional conformal radiotherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Poli, Ana Paula Diniz Fortuna, E-mail: anapaulafortuna@yahoo.com.br [Universidade Estadual de Campinas (CAISM/UNICAMP), Campinas, SP (Brazil). Centro de Atencao Integrada a Saude da Mulher. Divisao de Radioterapia; Dias, Rodrigo Souza; Giordani, Adelmo Jose; Segreto, Helena Regina Comodo; Segreto, Roberto Araujo [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Divisao de Radioterapia

    2016-01-15

    Objective: To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Materials and Methods: Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results: The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation (p = 0.037). A baseline rectal volume superior to 70 cm{sup 3} had a significant influence on the prostate motion in the anteroposterior direction (p = 0.045). Conclusion: The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm{sup 3}. Therefore, the treatment of patients with a rectal volume > 70 cm{sup 3} should be re-planned with appropriate rectal preparation. Keywords: Rectal volume; Prostate cancer; Three-dimensional conformal radiotherapy. (author)

  5. Conformal radiotherapy for locally advanced juvenile nasopharyngeal angio-fibroma

    Directory of Open Access Journals (Sweden)

    Supriya Mallick

    2015-01-01

    Full Text Available Purpose: To assess the efficacy of radiation in the treatment of juvenile nasopharyngeal angiofibroma (JNA. Materials and Methods: Data were retrieved for JNA treated with radiotherapy from 1987-2012. The demographics, treatment and outcome data were recorded in predesigned proforma. Results: Data of 32 patients were retrieved. Median age was 17 years (range: 12-33 years. All patients received radiation because of refractory, residual or unresectable locally advanced disease. All patients were planned with a three-dimensional conformal technique (3DCRT. The median radiation dose was 30 Gray (range: 30-45 Gray. Median follow-up was 129 months (range: 1-276 months. At the last follow-up, 13 patients were found to have a radiological complete response. Two patients progressed 38 and 43 months after completion of treatment and opted for alternative treatment. One patient developed squamous cell carcinoma of the nasal ale 15 years after radiation. Conclusion: Conformal radiotherapy shows promise as an alternative treatment approach for locally advanced JNA and confers long-term disease control with minimal toxicity.

  6. Experience in the radiotherapy department of Hospital Hermanos Ameijeiras in the use of 3DCRT 2drt and

    International Nuclear Information System (INIS)

    Sola Rodriguez, Yeline; Rodriguez Zayas, Michael; Perez Guevara, Adrian

    2009-01-01

    The introduction of TPS Precise Plan and the installation of an Elekta linear accelerator Entailed Precise Radiotherapy Service HHA 2DRT the evolution of a 3DCRT, the latter being a term used to describe the design and delivery planning radiation treatments based on 3D images, with fields individually shaped to the target volume and improved procedures evaluation of plans. Because of this it is necessary to estimate uncertainty in the delivered dose, which is evaluated in the 2D process 3DCRT, with emphasis on obtaining anatomical information (contour-meter vs TAC) design fields (open field vs MLC), dosimetric calculations, evaluation treatment plan and verification of isocenter. In this work took only internal processes in the treatment, such as location of the target volume and organs at risk, correction for inhomogeneities, etc. We excluded the uncertainties common to both modalities, such as: camera calibration, repeatability errors, among others. It took 40 cases treated: 20 with technical and 20 technical 2DRT 3DCRT for estimate the uncertainty of the delivered dose given each factor separately, say those involved in the planning process and supply of the treatment. This study implements a methodology which maintains or always reported decreasing uncertainties will lead to an increase quality of care. (author)

  7. The evolution of rectal and urinary toxicity and immune response in prostate cancer patients treated with two three-dimensional conformal radiotherapy techniques

    Czech Academy of Sciences Publication Activity Database

    Vránová, J.; Vinakurau, S.; Richter, J.; Starec, M.; Fišerová, Anna; Rosina, J.

    2011-01-01

    Roč. 2, č. 6 (2011), s. 1-13 ISSN 1748-717X R&D Projects: GA AV ČR IAA500200620 Institutional research plan: CEZ:AV0Z50200510 Keywords : 3-dimensional conformal radiotherapy (3DCRT) * gastrointestinal and genitourinary toxicity * prostate cancer Subject RIV: EC - Immunology Impact factor: 2.321, year: 2011

  8. A decision model to estimate the cost-effectiveness of intensity modulated radiation therapy (IMRT) compared to three dimensional conformal radiation therapy (3DCRT) in patients receiving radiotherapy to the prostate bed

    International Nuclear Information System (INIS)

    Carter, Hannah E.; Martin, Andrew; Schofield, Deborah; Duchesne, Gillian; Haworth, Annette; Hornby, Colin; Sidhom, Mark; Jackson, Michael

    2014-01-01

    Background: Intensity modulated radiation therapy (IMRT) is a radiation therapy technology that facilitates the delivery of an improved dose distribution with less dose to surrounding critical structures. This study estimates the longer term effectiveness and cost-effectiveness of IMRT in patients post radical prostatectomy. Methods: A Markov decision model was developed to calculate the incremental quality adjusted life years (QALYs) and costs of IMRT compared with three dimensional conformal radiation therapy (3DCRT). Costs were estimated from the perspective of the Australian health care system. Results: IMRT was both more effective and less costly than 3DCRT over 20 years, with an additional 20 QALYs gained and over $1.1 million saved per 1000 patients treated. This result was robust to plausible levels of uncertainty. Conclusions: IMRT was estimated to have a modest long term advantage over 3DCRT in terms of both improved effectiveness and reduced cost. This result was reliant on clinical judgement and interpretation of the existing literature, but provides quantitative guidance on the cost effectiveness of IMRT whilst long term trial evidence is awaited

  9. Dosimetric study of volumetric arc modulation with RapidArc and intensity-modulated radiotherapy in patients with cervical cancer and comparison with 3-dimensional conformal technique for definitive radiotherapy in patients with cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Guy, Jean-Baptiste [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France); Falk, Alexander T. [Department of Radiation Oncology, Centre Antoine Lacassagne, Nice (France); Auberdiac, Pierre [Department of Radiation Oncology, Clinique Claude Bernard, Albi (France); Cartier, Lysian; Vallard, Alexis [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France); Ollier, Edouard [Department of Pharmacology-Toxicology, Centre Hospitalier Universitaire de Saint-Etienne, Saint-Priest en Jarez (France); Trone, Jane-Chloé; Khodri, Moustapha [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France); Chargari, Cyrus [Department of Radiation Oncology, Hôpital d’instruction de Armées du Val-de-Grâce, Paris (France); Magné, Nicolas, E-mail: nicolas.magne@icloire.fr [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France)

    2016-04-01

    Introduction: For patients with cervical cancer, intensity-modulated radiation therapy (IMRT) improves target coverage and allows dose escalation while reducing the radiation dose to organs at risk (OARs). In this study, we compared dosimetric parameters among 3-dimensional conformal radiotherapy (3D-CRT), “step-and-shoot” IMRT, and volumetric intensity-modulated arc radiotherapy (VMAT) in a series of patients with cervical cancer receiving definitive radiotherapy. Computed tomography (CT) scans of 10 patients with histologically proven cervical cancer treated with definitive radiation therapy (RT) from December 2008 to March 2010 at our department were selected for this study. The gross tumor volume (GTV) and clinical target volume (CTV) were delineated following the guidelines of the Gyn IMRT consortium that included cervix, uterus, parametrial tissues, and the pelvic nodes including presacral. The median age was 57 years (range: 30 to 85 years). All 10 patients had squamous cell carcinoma with Federation of Gynecology and Obstetrics (FIGO) stage IB-IIIB. All patients were treated by VMAT. OAR doses were significantly reduced for plans with intensity-modulated technique compared with 3D-CRT except for the dose to the vagina. Between the 2 intensity-modulated techniques, significant difference was observed for the mean dose to the small intestine, to the benefit of VMAT (p < 0.001). There was no improvement in terms of OARs sparing for VMAT although there was a tendency for a slightly decreased average dose to the rectum: − 0.65 Gy but not significant (p = 0.07). The intensity modulation techniques have many advantages in terms of quality indexes, and particularly OAR sparing, compared with 3D-CRT. Following the ongoing technologic developments in modern radiotherapy, it is essential to evaluate the intensity-modulated techniques on prospective studies of a larger scale.

  10. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC. A direct comparison of PET-based treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Ruebe, Christian [Saarland University Medical School, Department of Radiotherapy and Radiation Oncology, Homburg/Saar (Germany)

    2016-02-15

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p < 0.001; IF: 74.3 vs. 70.1 Gy, p < 0.03). With IMRT-IF, a PD of at least 66 Gy was achieved for 95 % of all plans. For IF as compared with ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p < 0.00001; 3D-CRT: 20.2 vs. 9.9 %, p < 0.00001). The esophageal NTCP showed a particularly good sparing with IMRT vs. 3D-CRT (ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels. (orig.) [German] Das Potenzial der intensitaetsmodulierten Strahlentherapie (IMRT) soll im Rahmen der FDG-PET basierten Bestrahlungsplanung des lokal fortgeschrittenen nichtkleinzelligen Bronchialkarzinoms (LA-NSCLC) fuer 2 Zielvolumenansaetze (Involved-Field-Bestrahlung, IF) sowie elektive Nodalbestrahlung (ENI) geprueft und mit der 3-D-konformalen Strahlentherapie (3-D-CRT

  11. Three dimensional conformal radiation therapy (3d-crt) in prostate carcinoma: for whom and how?; La radiotherapie conformationnelle dans le cancer de la prostate: pour qui et comment?

    Energy Technology Data Exchange (ETDEWEB)

    Bey, P.; Beckendorf, V.; Aletti, P.; Marchesi, V. [Centre Alexis-Vautrin, Dept. de Radiotherapie, 54 - Vandoeuvre-les-Nancy (France)

    2002-05-01

    External radiotherapy is one of the modalities use o cure localized prostate carcinoma. Most of localized prostate carcinomas, specially those of the intermediate prognostic group, may benefit from escalated dose above 70 Gy at least as regard biochemical and clinical relapse free survival. 3D-CRT allows a reduction of the dose received by organs at risk and an increase of prostate dose over 70 Gy. It is on the way to become a standard. Intensity modulated radiation therapy increases dose homogeneity and reduces rectal dose. These methods necessitate rigorous procedures in reproducibility, delineation of volumes, dosimetry, daily treatment. They need also technological and human means. It is clear that localized prostate cancer is a good example for evaluation of these new radiotherapy modalities. (author)

  12. A custom made phantom for dosimetric audit and quality assurance of three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Radaideh, K.M.; Matalqah, L.M.; Matalqah, L.M.; Tajuddin, A.A.; Luen, F.W.L.; Bauk, S.; Abdel Munem, E.M.E.

    2012-01-01

    The ultimate check of the actual dose delivered to a patient in radiotherapy can be achieved by using dosimetric measurements. The aims of this study were to develop and evaluate a custom handmade head and neck phantom for evaluation of Three-Dimensional Conformal Radiation Therapy (3D-CRT) dose planning and delivery. A phantom of head and neck region of a medium built male patient with nasopharyngeal cancer was constructed from Perspex material. Primary and secondary Planning Target Volume (PTV) and twelve Organs at Risk (OAR) were delineated using Treatment Planning System (TPS) guided by computed tomography printout transverse images. One hundred and seven (107) holes distributed among the organs were loaded with Rod-shaped Thermoluminescent dosimeters (LiF:Mg, Ti TLDs) after common and individual calibration. Head and neck phantom was imaged, planned and irradiated conformally (3D-CRT) by linear accelerator (LINAC Siemens Artiste). The planned predicted doses by TPS at PTV and OAR regions were obtained and compared with the TLD measured doses using the phantom. Repeated TLD measurements were reproducible with a percent standard deviation of < 3.5 %. Moreover, the average of dose discrepancies between TLDs reading and TPS predicted doses were found to be < 5.3 %. The phantom's preliminary results have proved to be a valuable tool for 3D-CRT treatment dose verification. (author)

  13. Procedure for image acquisition and dosimetric planning for prostate cancer with 3D-CRT in the MIRS 3.0

    International Nuclear Information System (INIS)

    Perez Velasquez, Reytel; Alvarez Zaldivar, Junior; Gonzalez Lopez, Nadia

    2009-01-01

    For over 30 years in the department of Radiotherapy of the Lenin Hospital has been doing conventional radiotherapy. In this paper we describe the dose planning procedure for patients with prostate cancer with 3D-CRT in the MIRS RTPS 3.0. The work ranges from imaging in the TAC including quality control of this, the definition of bodies radio therapists medical risk to the data to be transferred to processing machine. With this procedure we have established guidelines for planning 3D-CRT treatments for other locations. (author)

  14. Auto-optimisation for three-dimensional conformal radiotherapy of nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Wu, V.W.C. E-mail: orvinwu@polyu.edu.hk; Kwong, D.W.L.; Sham, J.S.T.; Mui, A.W.L

    2003-08-01

    Purpose: The purpose of this study was to evaluate the application of auto-optimisation in the treatment planning of three-dimensional conformal radiotherapy (3DCRT) of nasopharyngeal carcinoma (NPC). Methods: Twenty-nine NPC patients were planned by both forward planning and auto-optimisation methods. The forward plans, which consisted of three coplanar facial fields, were produced according to the routine planning criteria. The auto-optimised plans, which consisted of 5-15 (median 9) fields, were generated by the planning system after prescribing the dose requirements and the importance weightings of the planning target volume and organs at risk. Plans produced by the two planning methods were compared by the dose volume histogram, tumour control probability (TCP), conformity index and normal tissue complication probability (NTCP). Results: The auto-optimised plans reduced the average planner's time by over 35 min. It demonstrated better TCP and conformity index than the forward plans (P=0.03 and 0.04, respectively). Besides, the parotid gland and temporo-mandibular (TM) joint were better spared with the mean dose reduction of 31.8 and 17.7%, respectively. The slight trade off was the mild dose increase in spinal cord and brain stem with their maximum doses remaining within the tolerance limits. Conclusions: The findings demonstrated the potentials of auto-optimisation for improving target dose and parotid sparing in the 3DCRT of NPC with saving of the planner's time.

  15. Auto-optimisation for three-dimensional conformal radiotherapy of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Wu, V.W.C.; Kwong, D.W.L.; Sham, J.S.T.; Mui, A.W.L.

    2003-01-01

    Purpose: The purpose of this study was to evaluate the application of auto-optimisation in the treatment planning of three-dimensional conformal radiotherapy (3DCRT) of nasopharyngeal carcinoma (NPC). Methods: Twenty-nine NPC patients were planned by both forward planning and auto-optimisation methods. The forward plans, which consisted of three coplanar facial fields, were produced according to the routine planning criteria. The auto-optimised plans, which consisted of 5-15 (median 9) fields, were generated by the planning system after prescribing the dose requirements and the importance weightings of the planning target volume and organs at risk. Plans produced by the two planning methods were compared by the dose volume histogram, tumour control probability (TCP), conformity index and normal tissue complication probability (NTCP). Results: The auto-optimised plans reduced the average planner's time by over 35 min. It demonstrated better TCP and conformity index than the forward plans (P=0.03 and 0.04, respectively). Besides, the parotid gland and temporo-mandibular (TM) joint were better spared with the mean dose reduction of 31.8 and 17.7%, respectively. The slight trade off was the mild dose increase in spinal cord and brain stem with their maximum doses remaining within the tolerance limits. Conclusions: The findings demonstrated the potentials of auto-optimisation for improving target dose and parotid sparing in the 3DCRT of NPC with saving of the planner's time

  16. Study on the photoneutrons produced in 15 MV medical linear accelerators : Comparison of three dimensional conformal radiotherapy and intensity modulated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Oh Nam [Gangneung Asan Hospital, Gangneung (Korea, Republic of); Yang, Oh Nam; Lim, Cheong Hwan [Hanseo Univ., Seosan (Korea, Republic of)

    2012-12-15

    Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photoneutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photon beams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

  17. Study on the photoneutrons produced in 15 MV medical linear accelerators : Comparison of three dimensional conformal radiotherapy and intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Yang, Oh Nam; Yang, Oh Nam; Lim, Cheong Hwan

    2012-01-01

    Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photoneutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photon beams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose

  18. Details of recurrence sites after elective nodal irradiation (ENI) using 3D-conformal radiotherapy (3D-CRT) combined with chemotherapy for thoracic esophageal squamous cell carcinoma--a retrospective analysis.

    Science.gov (United States)

    Yamashita, Hideomi; Okuma, Kae; Wakui, Reiko; Kobayashi-Shibata, Shino; Ohtomo, Kuni; Nakagawa, Keiichi

    2011-02-01

    To describe patterns of recurrence of elective nodal irradiation (ENI) in definitive chemoradiotherapy (CRT) for thoracic esophageal squamous cell carcinoma (SqCC) using 3D-conformal radiotherapy. One hundred and twenty-six consecutive patients with stages I-IVB thoracic esophageal SqCC newly diagnosed between June 2000 and July 2009 and treated with 3D-CRT in our institution were recruited from our database. Definitive CRT consisted of two cycles of nedaplatin/5FU repeated every 4 weeks, with concurrent radiation therapy of 50-50.4 Gy in 25-28 fractions. Until completion, radiotherapy was delivered to the N1 and M1a lymph nodes as ENI in addition to gross tumor volume. All 126 patients were included in this analysis, and their tumors were staged as follows: T1/T2/T3/T4, 28/18/54/26; N0/N1, 50/76; M0/M1a/M1b, 91/5/30. The mean follow-up period for the 63 surviving patients was 28.3 (±22.8) months. Eighty-seven patients (69%) achieved complete response (CR) without any residual tumor at least once after completion of CRT. After achieving CR, each of 40 patients experienced failures (local=20 and distant=20) and no patient experienced elective nodal failure without having any other site of recurrence. The upper thoracic esophageal carcinoma showed significantly more (34%) relapses at the local site than the middle (9%) or lower thoracic (11%) carcinomas. The 2-year and 3-year overall survival was 56% and 43%, respectively. The 1-year, 2-year and 3-year disease-free survival was 46%, 38% and 33%, respectively. In CRT for esophageal SqCC, ENI was effective for preventing regional nodal failure. The upper thoracic esophageal carcinomas had significantly more local recurrences than the middle or lower thoracic sites. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  19. Prognosis comparison of three-dimensional conformal radiotherapy/intensity modulated radiation therapy for esophageal carcinoma with local regional lymph node metastasis

    International Nuclear Information System (INIS)

    Wang Yuxiang; Wang Jun; Wang Yi; Tian Dandan; Yang Jie; Zhu Shuchai

    2011-01-01

    Objective: To explore the prognosis and related factor of esophageal carcinoma with locoregional lymph node metastasis (N 1 ) treated with three-dimensional conformal radiotherapy (3DCRT) or intensity modulated radiation therapy (IMRT). Methods: From January 2001 to December 2008, 60 patients of esophageal carcinoma with local regional lymph node metastasis were treated with 3DCRT and 52 with IMRT. For all patients,dose of tumor was 56 - 70 Gy/28 - 35 fraction/5.6 - 7.0 weeks. Among them, 58 cases was treated with chemotherapy including cisplatin and 5-fluorouracil; 40 with concurrent chemoradiotherapy and 18 with sequential radiotherapy and chemotherapy. Results: After radiotherapy,the total efficiency rate was 98.2%, 96.7% in 3DCRT and 100% in IMRT (χ 2 =1.77, P =0.184). The follow-up rate was 99.1%. The number of patients completed follow-up were 68 and 53, respectively at 2-year and 3-year. The 1 and 3-year overall survival rates were 62.5%, 23.7%, respectively; the median survival time was 17 months. The 1 and 3-year survival rates and median were 52%, 19% and 12.4 months in 3DCRT and 75%, 40% and 17 months in IMRT, respectively (χ 2 =4.74, P =0.030). The 1 and 3-year free-recurrence survival rates were 64%, 45% in 3DCRT and 72%, 59% in IMRT (χ 2 =2.27, P =0.132), respectively. With univariate analysis, for female, ages ≤ 65, tumor located in cervical and upper-thoracic, >5 cm lesion length in barium esophagogram, ≤4 cm the largest diameter of lesion in CT scanning image, T 4 stage, or semiliquid or liquid diet before radiotherapy, survival rate were higher in IMRT than in 3DCRT group (χ 2 =4.63, 5.56, 7.19, 5.08, 4.43, 4.48, 8.25; P=0.031, 0.018, 0.007, 0.025, 0.035, 0.034, 0.004, respectively); but for male, ages > 65, tumor located in middle and lower-thoracic, ≤5 cm lesion length in barium esophagogram, >4 cm the largest diameter of lesion in CT scanning image, T 1-3 stage, or normal diet before radiotherapy, chemotherapy and dose of radiotherapy

  20. FXG dosimeter response for three-dimensional conformal radiotherapy using different evaluation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Cavinato, Christianne C.; Campos, Leticia L., E-mail: ccavinato@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Souza, Benedito H.; Carrete Junior, Henrique; Daros, Kellen A.C.; Medeiros, Regina B., E-mail: bhsouza@unifesp.b, E-mail: daros.kellen@unifesp.b, E-mail: rbitel-li.ddi@epm.b [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Dept. de Diagnostico por Imagem; Giordani, Adelmo J. [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Servico de Radioterapia

    2011-07-01

    This work aims to compare the dose-response of the Fricke xylenol gel (FXG) dosimeter developed at IPEN using 270 Bloom gelatin from porcine skin made in Brazil evaluated using the magnetic resonance imaging (MRI) technique with the dosimetric response evaluated using the optical absorption (OA) spectrophotometry technique, in order to verify the possibility of quality assurance (QA) and reproducibility of FXG dosimeter to be carried out routinely using the OA technique for three-dimensional conformal radiotherapy (3DCRT) application using a 6 MV photons linear accelerator. The response in function of the absorbed dose of FXG dosimeter developed at IPEN presents linear behavior in clinical interest dose range when irradiated with Co-60 gamma radiation and 6 MV photons and evaluated using the MRI and OA techniques. The results indicate that the optical technique can be used for QA of FXG dosemeter when used in the possible application in QA of 3DCRT. (author)

  1. FXG dosimeter response for three-dimensional conformal radiotherapy using different evaluation techniques

    International Nuclear Information System (INIS)

    Cavinato, Christianne C.; Campos, Leticia L.; Souza, Benedito H.; Carrete Junior, Henrique; Daros, Kellen A.C.; Medeiros, Regina B.; Giordani, Adelmo J.

    2011-01-01

    This work aims to compare the dose-response of the Fricke xylenol gel (FXG) dosimeter developed at IPEN using 270 Bloom gelatin from porcine skin made in Brazil evaluated using the magnetic resonance imaging (MRI) technique with the dosimetric response evaluated using the optical absorption (OA) spectrophotometry technique, in order to verify the possibility of quality assurance (QA) and reproducibility of FXG dosimeter to be carried out routinely using the OA technique for three-dimensional conformal radiotherapy (3DCRT) application using a 6 MV photons linear accelerator. The response in function of the absorbed dose of FXG dosimeter developed at IPEN presents linear behavior in clinical interest dose range when irradiated with Co-60 gamma radiation and 6 MV photons and evaluated using the MRI and OA techniques. The results indicate that the optical technique can be used for QA of FXG dosemeter when used in the possible application in QA of 3DCRT. (author)

  2. SU-E-T-63: Carotid Sparing Tomohelical Three Dimensional Conformal Radiotherapy for T1N0 Glottic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hong, C; Ju, S; Ahn, Y; Oh, D; Noh, J; Chung, K; Kim, J; Han, Y; Choi, D [Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: We investigated the dosimetric benefit and treatment efficiency of carotid-sparing TomoHelical (TH) three-dimensional conformal radiotherapy (3DCRT) for early glottic cancer. Methods: Computed tomography (CT) simulation was performed for 10 patients with early-stage (T1N0M0) glottic squamous cell carcinoma. The clinical target volume, planning target volume (PTV), carotid artery (CA), and spinal cord (SP) were delineated for each CT data set. Two-field 3DCRT (2F-3DCRT), three-field intensity-modulated radiation therapy (IMRT) (3F-IMRT), TomoHelical-IMRT (TH-IMRT), and TH-3DCRT plans were generated, with a total prescribed dose of 67.5 Gy in 30 fractions to the PTV for each patient. In order to evaluate plan quality, dosimetric characteristics were compared in terms of the conformity index (CI) and homogeneity index (HI) for the PTV, V35, V50, and V63 for the CAs and in terms of the maximum dose for the SP. Additionally, treatment planning and delivery times were compared to evaluate treatment efficiency. Results: The CIs for 3F-IMRT (0.650±0.05), TH-IMRT (0.643±0.03), and TH-3DCRT (0.631±0.03) were much better than that for 2F-3DCRT (0.318±0.03). The HIs for TH-IMRT (1.053±0.01) and TH-3DCRT (1.055±0.01) were slightly better than those for 2F-3DCRT (1.062±0.01) and 3F-IMRT (1.091±0.007). 2F-3DCRT showed poor CA sparing in terms of the V35, V50, and V63 compared to 3F-IMRT, TH-IMRT, and TH-3DCRT (p<0.05), whereas there was no significant dose difference between 3F-IMRT, TH-IMRT, and TH-3DCRT (p>0.05). The maximum dose to the SP with all plans was below 45 Gy. The treatment planning times for 2F-3DCRT (5.9±0.66 min) and TH-3DCRT (7.32±0.94 min) were much lower than those for 3F-IMRT (45.51±2.76 min) and TH-IMRT (35.58±4.41 min), whereas the delivery times with all plans was below 3 minutes. Conclusion: TH-3DCRT showed excellent carotid sparing capability, comparable to that with TH-IMRT, with high treatment efficiency and short planning and

  3. Procedure for image acquisition and dose planning of prostate cancer with 3D-CRT in the MIRS 3.0

    International Nuclear Information System (INIS)

    Perez Velasquez, Reytel; Alvarez Zaldivar, Junior; Gonzalez Lopez, Nadia

    2009-01-01

    For over 30 years in the department of Radiotherapy of the Lenin Hospital has been making conventional radiotherapy. In the present work is presented the procedure for dosimetric planning of patients with prostate cancer with 3D-CRT in the MIRS RTPS 3.0. The work ranges from image acquisition in the TAC, its including quality control, the definition of organs at risk by medical radiation therapists to the data to be transferred to the treatment machine. With this procedure has been possible to establish guidelines for planning 3D-CRT treatments for other locations. (author)

  4. Quality of Life and Survival Outcome for Patients With Nasopharyngeal Carcinoma Receiving Three-Dimensional Conformal Radiotherapy vs. Intensity-Modulated Radiotherapy-A Longitudinal Study

    International Nuclear Information System (INIS)

    Fang, F.-M.; Chien, C.-Y.; Tsai, W.-L.; Chen, H.-C.; Hsu, H.-C.; Lui, C.-C.; Huang, T.-L.

    2008-01-01

    Purpose: To investigate the changes of quality of life (QoL) and survival outcomes for patients with nasopharyngeal carcinoma (NPC) treated by three-dimensional conformal radiotherapy (3D-CRT) vs. intensity-modulated radiotherapy (IMRT). Methods and Materials: Two hundred and three newly diagnosed NPC patients, who were curatively treated by 3D-CRT (n = 93) or IMRT (n = 110) between March 2002 and July 2004, were analyzed. The distributions of clinical stage according to American Joint Committee on Cancer 1997 were I: 15 (7.4%), II: 78 (38.4%), III: 74 (36.5%), and IV: 36 (17.7%). QoL was longitudinally assessed by the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30 and the EORTC QLQ-H and N35 questionnaires at the five time points: before RT, during RT (36 Gy), and 3 months, 12 months, and 24 months after RT. Results: The 3-year locoregional control, metastasis-free survival, and overall survival rates were 84.8%, 76.7%, and 81.7% for the 3D-CRT group, respectively, compared with 84.2%, 82.6%, and 85.4% for the IMRT group (p value > 0.05). A general trend of maximal deterioration in most QoL scales was observed during RT, followed by a gradual recovery thereafter. There was no significant difference in most scales between the two groups at each time point. The exception was that patients treated by IMRT had a both statistically and clinically significant improvement in global QoL, fatigue, taste/smell, dry mouth, and feeling ill at the time point of 3 months after RT. Conclusions: The potential advantage of IMRT over 3D-CRT in treating NPC patients might occur in QoL outcome during the recovery phase of acute toxicity

  5. Setup error in three-dimensional conformal radiotherapy for thoracic esophageal carcinoma

    International Nuclear Information System (INIS)

    Hong Jinsheng; Zhang Weijian; Chen Jinmei; Cai Chuanshu; Ke Chunlin; Chen Xiuying; Wu Bing; Guo Feibao

    2009-01-01

    Objective: To study the setup errors in three-dimensional conformal radiotherapy (3DCRT) for thoracic esophageal carcinoma using electronic portal imaging device(EPID) and calculate the margins from CTV to PTV. Methods: Forty-one patients with thoracic esophageal carcinoma who received 3DCRT were continuously enrolled into this study. The anterior and lateral electronic portal images (EPI) were aquired by EPID once a week. The setup errors were obtained through comparing the difference between EPI and digitally reconstructed radiographs (DRR). Then the setup margins from CTV to PTV were calculated. By using self paired design, 22 patients received definitive radiotherapy with different margins. Group A: the margins were 10 mm in all the three axes; Group B: the margins were aquired in this study. The difference were compared by Paired t-test or Wilcoxon signed-rank test. Results: The margins from CTV to PTV in x, y and z axes were 8.72 mm, 10.50 mm and 5.62 mm, respectively. Between the group A and group B, the difference of the maximum dose of the spinal cord was significant(4638.7 cGy ± 1449.6 cGy vs. 4310.2 cGy ± 1528.7 cGy; t=5.48, P=0.000), and the difference of NTCP for the spinal cord was also significant (4.82% ± 5.99% vs. 3.64% ± 4.70%; Z=-2.70, P=0.007). Conclusions: For patients with thoracic esophageal carcinoma who receive 3DCRT in author's department, the margins from CTV to PTV in x, y and z axes were 8.72 mm, 10.50 mm and 5.62 mm, respectively. The spinal cord could be better protected by using these setup margins than using 10 mm in each axis. (authors)

  6. Evidence-based review of three-dimensional conformal radiotherapy for localized prostate cancer: An ASTRO outcomes initiative

    International Nuclear Information System (INIS)

    Morris, David E.; Emami, Bahman; Mauch, Peter M.; Konski, Andre A.; Tao, May L.; Ng, Andrea K.; Klein, Eric A.; Mohideen, Najeeb; Hurwitz, Mark D.; Fraas, Bendick A.; Roach, Mack; Gore, Elizabeth M.; Tepper, Joel E.

    2005-01-01

    Purpose: To perform a systematic review of the evidence to determine the efficacy and effectiveness of three-dimensional conformal radiotherapy (3D-CRT) for localized prostate cancer; provide a clear presentation of the key clinical outcome questions related to the use of 3D-CRT in the treatment of localized prostate cancer that may be answered by a formal literature review; and provide concise information on whether 3D-CRT improves the clinical outcomes in the treatment of localized prostate cancer compared with conventional RT. Methods and Materials: We performed a systematic review of the literature through a structured process developed by the American Society for Therapeutic Radiology and Oncology's Outcomes Committee that involved the creation of a multidisciplinary task force, development of clinical outcome questions, a formal literature review and data abstraction, data review, and outside peer review. Results: Seven key clinical questions were identified. The results and task force conclusions of the literature review for each question are reported. Conclusion: The technological goals of reducing morbidity with 3D-CRT have been achieved. Randomized trials and follow-up of completed trials remain necessary to address these clinical outcomes specifically with regard to patient subsets and the use of hormonal therapy

  7. Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality

    International Nuclear Information System (INIS)

    Ling, C. Clifton; Humm, John; Larson, Steven; Amols, Howard; Fuks, Zvi; Leibel, Steven; Koutcher, Jason A.

    2000-01-01

    Purpose: The goals of this study were to survey and summarize the advances in imaging that have potential applications in radiation oncology, and to explore the concept of integrating physical and biological conformality in multidimensional conformal radiotherapy (MD-CRT). Methods and Materials: The advances in three-dimensional conformal radiotherapy (3D-CRT) have greatly improved the physical conformality of treatment planning and delivery. The development of intensity-modulated radiotherapy (IMRT) has provided the 'dose painting' or 'dose sculpting' ability to further customize the delivered dose distribution. The improved capabilities of nuclear magnetic resonance imaging and spectroscopy, and of positron emission tomography, are beginning to provide physiological and functional information about the tumor and its surroundings. In addition, molecular imaging promises to reveal tumor biology at the genotype and phenotype level. These developments converge to provide significant opportunities for enhancing the success of radiotherapy. Results: The ability of IMRT to deliver nonuniform dose patterns by design brings to fore the question of how to 'dose paint' and 'dose sculpt', leading to the suggestion that 'biological' images may be of assistance. In contrast to the conventional radiological images that primarily provide anatomical information, biological images reveal metabolic, functional, physiological, genotypic, and phenotypic data. Important for radiotherapy, the new and noninvasive imaging methods may yield three-dimensional radiobiological information. Studies are urgently needed to identify genotypes and phenotypes that affect radiosensitivity, and to devise methods to image them noninvasively. Incremental to the concept of gross, clinical, and planning target volumes (GTV, CTV, and PTV), we propose the concept of 'biological target volume' (BTV) and hypothesize that BTV can be derived from biological images and that their use may incrementally improve

  8. Prospective study on the dose distribution to the acoustic structures during postoperative 3D conformal radiotherapy for parotid tumors. Dosimetric and audiometric aspects

    International Nuclear Information System (INIS)

    Jereczek-Fossa, Barbara A.

    2011-01-01

    To analyze dose distribution in the hearing organ and to evaluate the dose effect on the hearing thresholds in patients treated with post-parotidectomy 3-dimensional conformal radiotherapy (3D-CRT). A total of 17 patients received post-parotidectomy 3D-CRT (median dose: 63 Gy). The audiometric evaluation comprised pure tone audiometry and tympanometry performed before radiotherapy (RT) and 3, 6, and 24 months after RT. The ear structures were delineated on planning computer tomography scans. Mean and maximum doses were calculated and dose-volume histograms were plotted. Before RT, the median baseline audiometric thresholds were normal. At 3 months post-RT, 3 patients were diagnosed as having middle ear underpressure and/or effusion that resolved completely by 6 months. During 2-year follow-up, none of the ears showed perceptive hearing loss at speech frequencies. The mean doses at ipsilateral external auditory canal, mastoids cells, tympanic case, Eustachian tube, semicircular canals, and cochlea were 44.8 Gy, 39.0 Gy, 30.9 Gy, 33.0 Gy, 19.6 Gy, and 19.2 Gy, respectively. The doses to the contralateral ear were negligible, except for the Eustachian tube (up to 28.2 Gy). Post-parotidectomy 3D-CRT is associated with relatively low doses to the ear and the surrounding structures. Post-RT audiometry did not show any permanent (neither conductive nor perceptive) hearing impairment. Only in 3 patients were there signs of transient unilateral dysfunction of the Eustachian tube observed during the first few months after RT. Longer follow-up and larger patient series are warranted to confirm these preliminary findings. (orig.)

  9. Dosimetric comparison of helical tomotherapy, intensity-modulated radiation therapy, volumetric-modulated arc therapy, and 3-dimensional conformal therapy for the treatment of T1N0 glottic cancer

    International Nuclear Information System (INIS)

    Ekici, Kemal; Pepele, Eda K.; Yaprak, Bahaddin; Temelli, Oztun; Eraslan, Aysun F.; Kucuk, Nadir; Altınok, Ayse Y.; Sut, Pelin A.; Alpak, Ozlem D.; Colak, Cemil; Mayadagli, Alpaslan

    2016-01-01

    Various radiotherapy planning methods for T1N0 laryngeal cancer have been proposed to decrease normal tissue toxicity. We compare helical tomotherapy (HT), linac-based intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and 3-D conformal radiotherapy (3D-CRT) techniques for T1N0 laryngeal cancer. Overall, 10 patients with T1N0 laryngeal cancer were selected and evaluated. Furthermore, 10 radiotherapy treatment plans have been created for all 10 patients, including HT, IMRT, VMAT, and 3D-CRT. IMRT, VMAT, and HT plans vs 3D-CRT plans consistently provided superior planning target volume (PTV) coverage. Similar target coverage was observed between the 3 IMRT modalities. Compared with 3D-CRT, IMRT, HT, and VMAT significantly reduced the mean dose to the carotid arteries. VMAT resulted in the lowest mean dose to the submandibular and thyroid glands. Compared with 3D-CRT, IMRT, HT, and VMAT significantly increased the maximum dose to the spinal cord It was observed that the 3 IMRT modalities studied showed superior target coverage with less variation between each plan in comparison with 3D-CRT. The 3D-CRT plans performed better at the D max of the spinal cord. Clinical investigation is warranted to determine if these treatment approaches would translate into a reduction in radiation therapy–induced toxicities.

  10. Intensity modulated radiotherapy (IMRT) in bilateral retinoblastoma

    International Nuclear Information System (INIS)

    Atalar, Banu; Ozyar, Enis; Gunduz, Kaan; Gungor, Gorkem

    2010-01-01

    External beam radiotherapy (EBRT) for retinoblastoma has traditionally been done with conventional radiotherapy techniques which resulted high doses to the surrounding normal tissues. A 20 month-old girl with group D bilateral retinoblastoma underwent intensity modulated radiotherapy (IMRT) to both eyes after failing chemoreduction and focal therapies including cryotherapy and transpupillary thermotherapy. In this report, we discuss the use of IMRT as a method for reducing doses to adjacent normal tissues while delivering therapeutic doses to the tumour tissues compared with 3-dimensional conformal radiotherapy (3DCRT). At one year follow-up, the patient remained free of any obvious radiation complications. Image guided IMRT provides better dose distribution than 3DCRT in retinoblastoma eyes, delivering the therapeutic dose to the tumours and minimizing adjacent tissue damage

  11. A comparison of swallowing dysfunction after three-dimensional conformal and intensity-modulated radiotherapy. A systematic review by the Italian Head and Neck Radiotherapy Study Group

    Energy Technology Data Exchange (ETDEWEB)

    Ursino, Stefano; Morganti, Riccardo; Cristaudo, Agostino; Paiar, Fabiola [University Hospital S. Chiara, Radiation Oncology, Pisa (Italy); D' Angelo, Elisa; Lohr, Frank [University Hospital, Radiation Oncology, Modena (Italy); Mazzola, Rosario [Sacro Cuore-Don Calabria Cancer Care Center, Radiation Oncology, Negrar-Verona (Italy); Merlotti, Anna; Russi, Elvio Grazioso [S. Croce e Carle Hospital, Radiation Oncology, Cuneo (Italy); Musio, Daniela [University Hospital La Sapienza, Radiation Oncology, Roma (Italy); Alterio, Daniela [European Institute of Oncology, Radiation Oncology, Advanced Radiotherapy Center, Milan (Italy); Bacigalupo, Almalina [AOU IRCCS San Martino - IST National Cancer Research Institute and University, Radiation Oncology, Genoa (Italy)

    2017-11-15

    Dysphagia is one of the most important treatment-related side effects in head and neck cancer (HNC), as it can lead to severe life-threating complications such as aspiration pneumonia and malnutrition. Intensity-modulated radiotherapy (IMRT) could reduce swallowing dysfunction by producing a concave dose distribution and reducing doses to the swallowing-related organs at risk (SWOARs). The aim of this study was to review the current literature in order to compare swallowing outcomes between IMRT and three-dimensional conformal radiotherapy (3DCRT). A search was conducted in the PubMed and Embase databases to identify studies on swallowing outcomes, both clinically and/or instrumentally assessed, after 3DCRT and IMRT. Dysphagia-specific quality of life and objective instrumental data are summarized and discussed. A total of 262 papers were retrieved from the searched databases. An additional 23 papers were retrieved by hand-searching the reference lists. Ultimately, 22 papers were identified which discussed swallowing outcomes after 3DCRT and IMRT for HNC. No outcomes from randomized trials were identified. Despite several methodological limitations, reports from the current literature seem to suggest better swallowing outcomes with IMRT compared to 3DCRT. Further improvements are likely to result from the increased use of IMRT plans optimized for SWOAR sparing. (orig.) [German] Dysphagie ist eine der wichtigsten Nebenwirkungen bei der Behandlung von Kopf-Hals-Tumoren (HNC), da sie zu lebensbedrohlichen Komplikationen wie Aspirationspneumonien und Mangelernaehrung fuehren kann. Durch Erzeugung konkaver Dosisverteilungen und durch die Reduzierung der Dosis an schluckrelevanten Strukturen (SWOAR) kann die IMRT Schluckstoerungen moeglicherweise vermindern. Ziel dieser Studie war es, die gegenwaertige Literaturlage hinsichtlich der Schluckfunktion nach IMRT und konformaler dreidimensionaler Strahlentherapie (3DCRT) systematisch zu ueberpruefen. Studien, die die

  12. Implementation of three dimensional conformal radiation therapy: prospects, opportunities, and challenges

    International Nuclear Information System (INIS)

    Vijayakumar, Srinivasan; Chen, George T.Y.

    1995-01-01

    Purpose: To briefly review scientific rationale of 3D conformal radiation therapy (3DCRT) and discuss the prospects, opportunities, and challenges in the implementation of 3DCRT. Some of these ideas were discussed during a workshop on 'Implementation of Three-Dimensional Conformal Radiation Therapy' in April 1994 at Bethesda, MD, and others have been discussed elsewhere in the literature. Methods and Materials: Local-regional control of cancer is an important component in the overall treatment strategy in any patient with cancer. It has been shown that failure to achieve local-regional control can lead to (a) an increase in chances of distant metastases, and (b) a decrease in the survival. In many disease sites, the doses delivered currently are inadequate to achieve satisfactory local tumor control rates; this is because in many sites, only limited doses of radiotherapy can be delivered due to the proximity of cancer to radiosensitive normal tissues. By conforming the radiotherapy beams to the tumor, doses to the tumors can be enhanced and doses to the normal tissues can be reduced. With the advances in 3DCRT, such conformation is possible now and is the rationale for using 3DCRT. However, a number of questions do remain that are not limited to the following: (a) What are the implications in terms of target volume definitions when implementing 3DCRT? (b) Are there some sites where research efforts can be focused to document the efficacy and cost effectiveness of 3DCRT? (c) How do we implement day-to-day 3DCRT treatment efficiently? (d) How do we transfer the technology from the university centers to the community without compromising quality? (e) What are all the quality assurance/quality improvement questions that need to be addressed and how do we ascertain quality assurance of 3DCRT? (f) Have we looked at cost-benefit ratios and quality of life (QOL) issues closely? Results: There is a need for defining multiple target volumes: gross tumor volume, clinical

  13. Three-dimensional conformal radiotherapy in the treatment of prostate cancer in Australia and New Zealand: Report on a survey of radiotherapy centres and the proceedings of a consensus workshop

    International Nuclear Information System (INIS)

    Tai, K.-H.; Duchesne, G.; See, A.; Berry, M.

    2004-01-01

    There is an increasing use of 3-D conformal radiotherapy (3DCRT) in the radiotherapeutic management of prostate cancer. The Faculty of Radiation Oncology Genito-Urinary Group carried out a survey of Australian and New Zealand radiotherapy centres in the preparation of a consensus workshop. Of the 19 centres that were represented, there were 24 radiation oncologists, 16 radiation therapists and 12 medical physicists. The survey collected demographic information and data on the practices undertaken at those centres when delivering curative radiotherapy in the treatment of prostate cancer. There was much variation in the delivery of treatment in the areas of patient set-up, contouring of target volumes and organs of interest during computer planning, the techniques and the dose constraints used in these techniques, the use of adjuvant androgen deprivation therapy and the quality assurance processes used in monitoring effects of treatment. This variability reflects the range of data in the published literature. Emerging trends of practices were also identified. This is a first report on a multi-disciplinary approach to the development of guidelines in 3DCRT of prostate cancer. Copyright (2004) Blackwell Science Pty Ltd

  14. Potency following high-dose three-dimensional conformal radiotherapy and the impact of prior major urologic surgical procedures in patients treated for prostate cancer

    International Nuclear Information System (INIS)

    Chinn, Daniel M.; Holland, John; Crownover, Richard L.; Roach, Mack

    1995-01-01

    Purpose: To assess the impact of high-dose three-dimensional conformal radiotherapy (3DCRT) on potency in patients treated for clinically localized prostate cancer and to identify factors that might predict the outcome of sexual function following treatment. Methods and Materials: One hundred twenty-four consecutive patients treated with 3DCRT for localized prostate cancer at UCSF between 1991-1993 were included in this retrospective analysis. Patient responses were obtained from a mailed questionnaire, telephone interviews, or departmental records. Median follow-up was 21 months. Results: Sixty patients reported having sexual function prior to 3DCRT, including 47 who were fully potent and 13 who were marginally potent. Of the remaining 64 patients, 45 were impotent, 7 were on hormones, 1 was status-postorchiectomy, and 11 were not evaluable. Following 3DCRT, 37 of 60 patients (62%) retained sexual function sufficient for intercourse. Of those with sexual function before irradiation, 33 of 47 (70%) of patients fully potent and 4 of 13 (31%) of patients marginally potent maintained function sufficient for intercourse (p < 0.01). Potency was retained in 6 of 15 (40%) patients with a history of a major urologic surgical procedure (MUSP) and in 31 of 45 (69%) with no history of a MUSP (p < 0.04). Transurethral resection of the prostate was the MUSP in eight of these patients, with four (50%) maintaining sexual function. Conclusions: Patients who receive definitive 3DCRT for localized prostate cancer appear to maintain potency similar to patients treated with conventional radiotherapy. However, patients who are marginally potent at presentation or who have a history of a MUSP appear to be at increased risk of impotence following 3DCRT

  15. Dosimetry analysis on radiation-induced acute esophagitis after three-dimensional conformal radiotherapy for non-small cell lung cancer

    International Nuclear Information System (INIS)

    ZZhu Shuchai; Cui Yanli; Li Juan; Liu Zhikun; Shen Wenbin; Su Jingwei; Wang Yuxiang

    2010-01-01

    Objective: To analyze the related factors with radiation-induced esophagitis after threedimensional conformal radiotherapy for non-small cell lung cancer (NSCLC), in order to explore the predictors for optimizing the treatment planning of NSCLC. Methods: From Aug 2000 to Dec 2004, 104 NSCLC patients received radiotherapy and were eligible for this study, 45 cases squamous cell carcinoma, 20 cases adenocarcinoma, 33 cases carrying with cancer cells by test and 6 case with no definitive pathologic feature.46 patients were treated with three dimensional conformal radiotherapy (3DCRT), the other 58 patients conventional radiotherapy (CRT) before later-course 3DCRT. All the patients received the prescribed dose between 60-78 Gy and the median dose 66 Gy. The correlation of the variables were evaluated by Spearman relationship analysis. The morbidity of radiation-induced esophagitis was analyzed by X 2 test. The multivariate effect on radiation-induced esophagitis was statistically processed by Logistic regression model. Results: In 104 patients, the morbidity of radiation- induced esophagitis was 46.2%, including 32 cases at grade 1, 15 cases at grade 2, 1 case at grade 3. Univariate analysis showed the maximal and mean dose of esophagus, the volume of esophagus irradiated, the values of V 40 , V 45 , V 50 , V 55 , V 60 , LETT 45 , LETT 50 , LETT 55 , LETT 60 for the esophagus were correlated with radiation-induced esophagitis. Logistic regression model showed that the maximum dose received by the esophagus was the independent factor of ≥ 2 grade radiation-induced esophagitis. Conclusions: The maxmal dose of esophagus received might be the important factor of radiation-induced esophagitis. (authors)

  16. The therapeutic effect of three-dimensional conformal radiation therapy combined with conventional radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Liang Feng; Lu Zhonghong; Yao Zhijun; Cao Yongzhen

    2011-01-01

    Objective: To observe the therapeutic effect of three-dimensional conformal radiation therapy (3DCRT) for nasopharyngeal carcinoma (NPC). Methods: 78 patients with NPC was treated by radiation schedule in two phases. In the first phase, nasopharyngeal lesions and metastases of all patients were treated by three-dimensional conformal radiation therapy (3DCRT) with a fraction of 2-5 Gy daily, 5 day per weeks, total dose 30 Gy. The second phase T1N0 or parts of T2N0 patients were done by Conventional radiotherapy with total dose 55 Gy on two small lateral opposing fields + with total dose 50 Gy on neck on tangential field,adding a 3 cm block. Patients with lymph node metastasis were given 55 Gy on the dacio-neck field (After 40 Gy, two small lateral opposing fields were used to boost the primary tumor while the spinal cord shielded) + with total dose 55 Gy on lower neck on tangential field. The upper bound of designed therapeutic field was set to connect with lower bound of main therapeutic field. Results: Three months after treatment,the rate of CR, PR, SD, PD were 38.5%, 55.1%, 5.1%, 1.3%, Total effective rate (CR+PR) were 93.6%. The 1-year, 2-year, 3-year and 5-year local-regional control rates were 92.3%, 88.5%, 78.2%, 70.5%.The 1-year, 2-year , 3-year and 5-year overall survival rate were 96.2%, 89.7%, 83.3%, 71.8%. Appearing early radiation response is well tolerated and no obviously mouth difficulties and cranial nerve damage observed. Conclusion: Clinical result of early-course three-dimensional conformal radiation therapy (3DCRT) for nasopharyngeal carcinoma (NPC) is good. (authors)

  17. Hepatitis B Virus Reactivation After Three-Dimensional Conformal Radiotherapy in Patients With Hepatitis B Virus-Related Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Kim, Ji Hoon; Park, Joong-Won; Kim, Tae Hyun; Koh, Dong Wook; Lee, Woo Jin; Kim, Chang-Min

    2007-01-01

    Purpose: To investigate whether three-dimensional conformal radiotherapy (3D-CRT) influences hepatitis B virus (HBV) reactivation and chronic hepatitis B (CHB) exacerbation in patients with HBV-related hepatocellular carcinoma (HCC). Methods and Materials: Of the 48 HCC patients with HBV who underwent 3D-CRT to the liver, 16 underwent lamivudine therapy before and during 3D-CRT (Group 1) and 32 did not receive antiviral therapy before 3D-CRT (Group 2). To analyze spontaneous HBV reactivation, we included a control group of 43 HCC patients who did not receive any specific treatment for HCC or CHB. Results: The cumulative rate of radiation-induced liver disease for Groups 1 and 2 was 12.5% (2 of 16) and 21.8% (7 of 32), respectively (p > 0.05). The cumulative rate of HBV reactivation was significantly greater in Group 2 (21.8%, 7 of 32) than in Group 1 (0%, 0/16) or the control group (2.3%, 1 of 43; p 0.05 each). The CHB exacerbations in the 4 Group 2 patients had radiation-induced liver disease features but were differentiated by serum HBV DNA changes. Two of these patients required antiviral therapy and effectively recovered with lamivudine therapy. Conclusions: In patients with HBV-related HCC undergoing 3D-CRT, HBV reactivation and consequent CHB exacerbation should be considered in the differential diagnosis of radiation-induced liver disease, and antiviral therapy might be considered for the prevention of liver function deterioration after RT

  18. Radiotherapy-induced secondary cancer risk for breast cancer: 3D conformal therapy versus IMRT versus VMAT

    International Nuclear Information System (INIS)

    Lee, Boram; Sung, Jiwon; Yoon, Myonggeun; Lee, Sunyoung

    2014-01-01

    This study evaluated the secondary cancer risk to various organs due to radiation treatment for breast cancer. Organ doses to an anthropomorphic phantom were measured using a photoluminescent dosimeter (PLD) for breast cancer treatment with 3D conformal radiation therapy (3D-CRT), intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Cancer risk based on the measured dose was calculated using the BEIR (Biological Effects of Ionizing Radiation) VII models. The secondary dose per treatment dose (50.4 Gy) to various organs ranged from 0.02 to 0.36 Gy for 3D-CRT, but from 0.07 to 8.48 Gy for IMRT and VMAT, indicating that the latter methods are associated with higher secondary radiation doses than 3D-CRT. The result of the homogeneity index in the breast target shows that the dose homogeneity of 3D-CRT was worse than those of IMRT and VMAT. The organ specific lifetime attributable risks (LARs) to the thyroid, contralateral breast and ipsilateral lung per 100 000 population were 0.02, 19.71, and 0.76 respectively for 3D-CRT, much lower than the 0.11, 463.56, and 10.59 respectively for IMRT and the 0.12, 290.32, and 12.28 respectively for VMAT. The overall estimation of LAR indicated that the radiation-induced cancer risk due to breast radiation therapy was lower with 3D-CRT than with IMRT or VMAT. (paper)

  19. Whole-pelvic radiotherapy with spot-scanning proton beams for uterine cervical cancer: a planning study

    International Nuclear Information System (INIS)

    Hashimoto, Shingo; Shibamoto, Yuta; Iwata, Hiromitsu; Ogino, Hiroyuki; Shibata, Hiroki; Toshito, Toshiyuki; Sugie, Chikao; Mizoe, Jun-etsu

    2016-01-01

    The aim of this study was to compare the dosimetric parameters of whole-pelvic radiotherapy (WPRT) for cervical cancer among plans involving 3D conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), or spot-scanning proton therapy (SSPT). The dose distributions of 3D-CRT-, IMRT-, and SSPT-based WPRT plans were compared in 10 patients with cervical cancer. All of the patients were treated with a prescribed dose of 50.4 Gy in 1.8-Gy daily fractions, and all of the plans involved the same planning target volume (PTV) constrictions. A 3D-CRT plan involving a four-field box, an IMRT plan involving seven coplanar fields, and an SSPT plan involving four fields were created. The median PTV D95% did not differ between the 3D-CRT, IMRT and SSPT plans. The median conformity index 95% and homogeneity index of the IMRT and SSPT were better than those of the 3D-CRT. The homogeneity index of the SSPT was better than that of the IMRT. SSPT resulted in lower median V20 values for the bladder wall, small intestine, colon, bilateral femoral heads, skin, and pelvic bone than IMRT. Comparing the Dmean values, SSPT spared the small intestine, colon, bilateral femoral heads, skin and pelvic bone to a greater extent than the other modalities. SSPT can reduce the irradiated volume of the organs at risk compared with 3D-CRT and IMRT, while maintaining excellent PTV coverage. Further investigations of SSPT are warranted to assess its role in the treatment of cervical cancer.

  20. Long-term urinary toxicity after 3-dimensional conformal radiotherapy for prostate cancer in patients with prior history of transurethral resection

    International Nuclear Information System (INIS)

    Sandhu, Ajaypal S.; Zelefsky, Michael J.; Lee, Henry J.; Lombardi, Danna; Fuks, Zvi; Leibel, Steven A.

    2000-01-01

    Purpose: To report on the long-term urinary morbidity among prostate cancer patients with a prior history of a transurethral resection of the prostate (TURP) treated with high-dose 3-dimensional conformal radiotherapy (3D-CRT). Methods and Materials: Between 1988 and 1997, 1100 patients with clinically localized prostate cancer were treated with 3D-CRT. Of these, 120 patients (8%) were identified as having had a prior TURP and are the subjects of this analysis. The median age was 71 years (range: 49-83 years). The clinical stages of the patients were T1c: 33 (28%); T2a: 38 (32%); T2b: 15 (13%); and T3: 34 (27%). Neoadjuvant androgen ablation therapy was given to 39 (33%). The median radiation dose prescribed to the planning target volume was 75.6 Gy (range: 64.8-81 Gy). The median elapsed time from TURP to initiation of 3D-CRT was 69 months (range: 4-360 months). The median follow-up time was 51 months (range: 18-109 months). Results: Five patients of the 120 with a prior history of TURP (4%) developed a urethral stricture after 3D-CRT which was corrected with dilatation. The 5-year actuarial likelihood of ≥ Grade 2 late urinary toxicities was 9%. No Grade 4 urinary toxicities were observed in this group of patients. Among 110 patients who were completely continent of urine prior to 3D-CRT, 10 (9%) developed stress incontinence requiring 1 pad daily for protection or experienced occasional leakage (not requiring pad protection). The 5-year incidence of ≥ Grade 1 stress incontinence was 18% in patients who developed acute ≥ Grade 2 GU symptoms during the course of 3D-CRT compared to 7% for patients who experienced Grade 1 or no acute urinary symptoms (p = 0.05). The radiation dose (≥75.6 Gy vs. <75.6 Gy), the number of prior TURP procedures, or the volume of resected tissue at the time of TURP had no significant impact on the long-term urinary morbidity outcome. A multivariate analysis demonstrated that the presence of Grade 2 acute urinary symptoms was the

  1. Incidental irradiation of mediastinal and hilar lymph node stations during 3D-conformal radiotherapy for non-small cell lung cancer

    International Nuclear Information System (INIS)

    Kepka, Lucyna; Bujko, Krzysztof; Zolciak-Siwinska, Agnieszka; Garmol, Dariusz

    2008-01-01

    Purpose. To estimate the doses of incidental irradiation in particular lymph node stations (LNS) in different extents of elective nodal irradiation (ENI) in 3D-conformal radiotherapy (3D-CRT) for non-small cell lung cancer (NSCLC). Methods. Doses of radiotherapy were estimated for particular LNS delineated according to the recommendations of the Univ. of Michigan in 220 patients treated using 3D-CRT with different (extended, limited and omitted) extents of ENI. Minimum doses and volumes of LNS receiving 40 Gy or more (V40) were compared for omitted vs. limited+extended ENI and limited vs. extended ENI. Results. For omission of the ENI the minimum doses and V40 for particular LNS were significantly lower than for patients treated with ENI. For the limited ENI group, the minimum doses for LNS 5, 6 lower parts of 3A and 3P (not included in the elective area) did not differ significantly from doses given to respective LNS for extended ENI group. When the V40 values for extended and limited ENI were compared, no significant differences were seen for any LNS, except for group 1/2R, 1/2L. Conclusions. Incidental irradiation of untreated LNS seems play a part in case of limited ENI, but not in cases without ENI. For subclinical disease the delineation of uninvolved LNS 5, 6, and lower parts of 3A, 3P may be not necessary, because these stations receive the substantial part of irradiation incidentally, if LNS 4R, 4L, 7, and ipsilateral hilum are included in the elective area while this is not case for stations 1 and 2

  2. Comparison of dosimetric parameters and toxicity in esophageal cancer patients undergoing 3D conformal radiotherapy or VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Muench, Stefan; Aichmeier, Sylvia; Duma, Marciana-Nona; Oechsner, Markus; Habermehl, Daniel [TU Muenchen, Department of Radiation Oncology, Klinikum rechts der Isar, Muenchen (Germany); Hapfelmeier, Alexander [TU Muenchen, Institute of Medical Statistics and Epidemiology (IMSE), Klinikum rechts der Isar, Muenchen (Germany); Feith, Marcus [TU Muenchen, Department of Visceral Surgery, Klinikum rechts der Isar, Muenchen (Germany); Combs, Stephanie E. [TU Muenchen, Department of Radiation Oncology, Klinikum rechts der Isar, Muenchen (Germany); Helmholtz Zentrum Muenchen, Institute of Innovative Radiotherapy (iRT), Oberschleissheim (Germany)

    2016-10-15

    Volumetric-modulated arc therapy (VMAT) achieves high conformity to the planned target volume (PTV) and good sparing of organs at risk (OAR). This study compares dosimetric parameters and toxicity in esophageal cancer (EC) patients treated with VMAT and 3D conformal radiotherapy (3D-CRT). Between 2007 and 2014, 17 SC patients received neoadjuvant chemoradiation (CRT) with VMAT. Dose-volume histograms and toxicity were compared between these patients and 20 treated with 3D-CRT. All patients were irradiated with a total dose of 45 Gy. All VMAT patients received simultaneous chemotherapy with cisplatin and 5-fluorouracil (5-FU) in treatment weeks 1 and 5. Of 20 patients treated with 3D-CRT, 13 (65 %) also received CRT with cisplatin and 5-FU, whereas 6 patients (30 %) received CRT with weekly oxaliplatin and cetuximab, and a continuous infusion of 5-FU (OE-7). There were no differences in baseline characteristics between the treatment groups. For the lungs, VMAT was associated with a higher V{sub 5} (median 90.1 % vs. 79.7 %; p = 0.013) and V{sub 10} (68.2 % vs. 56.6 %; p = 0.014), but with a lower V{sub 30} (median 6.6 % vs. 11.0 %; p = 0.030). Regarding heart parameters, VMAT was associated with a higher V{sub 5} (median 100.0 % vs. 91.0 %; p = 0.043), V{sub 10} (92.0 % vs. 79.2 %; p = 0.047), and D{sub max} (47.5 Gy vs. 46.3 Gy; p = 0.003), but with a lower median dose (18.7 Gy vs. 30.0 Gy; p = 0.026) and V{sub 30} (17.7 % vs. 50.4 %; p = 0.015). Complete resection was achieved in 16 VMAT and 19 3D-CRT patients. Due to systemic progression, 2 patients did not undergo surgery. The most frequent postoperative complication was anastomosis insufficiency, occurring in 1 VMAT (6.7 %) and 5 3D-CRT patients (27.8 %; p = 0.180). Postoperative pneumonia was seen in 2 patients of each group (p = 1.000). There was no significant difference in 3-year overall (65 % VMAT vs. 45 % 3D-CRT; p = 0.493) or 3-year progression-free survival (53 % VMAT vs. 35 % 3D-CRT; p = 0

  3. Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques

    International Nuclear Information System (INIS)

    Nutting, Christopher M.; Rowbottom, Carl G.; Cosgrove, Vivian P.; Henk, J. Michael; Dearnaley, David P.; Robinson, Martin H.; Conway, John; Webb, Steve

    2001-01-01

    Background and purpose: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution. Materials and methods: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stem, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated. Results: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170 degree sign from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation. Conclusions: For patients with parotid gland tumours

  4. Class solution to decrease rectal dose in prostate radiotherapy treatments 3D-CRT

    International Nuclear Information System (INIS)

    Andres Rodriguez, C.; Tortosa Oliver, R.; Alonso Hernandez, D.; Mari Palacios, A.; Castillo Belmonte, A. del

    2011-01-01

    This paper contains a method developed in our center with conventional 3D radiotherapy techniques to increase the dose conformation around the target volume in prostate cancer treatments significantly reduced the doses to the rectum. To evaluate the goodness of the method, the results are compared with two classical techniques of treatment.

  5. Does gap-free intensity modulated chemoradiation therapy provide a greater clinical benefit than 3D conformal chemoradiation in patients with anal cancer?

    International Nuclear Information System (INIS)

    Dewas, Claire Vautravers; Créhange, Gilles; Maingon, Philippe; Dalban, Cécile; Petitfils, Aurélie; Peignaux, Karine; Truc, Gilles; Martin, Etienne; Khoury, Cédric; Dewas, Sylvain

    2012-01-01

    Chemoradiation is the standard treatment for anal cancer. 3D conformal radiotherapy (3D-CRT) is usually split in 2 sequences with a therapeutic break (gap) in between. Intensity-modulated radiation therapy (IMRT) makes it possible to reduce treatment time by abandoning this gap. The purpose of this study was to compare outcomes and toxicities in patients treated with either IMRT or 3D-CRT. Between 2004 and 2011, the data of 51 patients treated with exclusive radiotherapy with or without concomitant chemotherapy for non-metastatic anal carcinoma were retrospectively analyzed. Twenty-seven patients were treated with 3D-CRT and 24 patients with IMRT, with a median dose delivered to the tumor of 59.4Gy [30.6-66.6], whatever the radiotherapy technique (p= 0.99). The median follow-up was 40 months [26.4-51.6]. There was no difference between the two groups for response to treatment (p= 0.46). Two-year overall survival, locoregional relapse-free survival and colostomy-free survival rates were 88.5%, 63% and 60.3%, respectively for the IMRT group and 81%, 76.5% and 81.1% for the 3D-CRT group (all NS). Ten patients (37%) in 3D-CRT and 11 patients (45.8%) in IMRT (p= 0.524) had grade 3 acute toxicity. No grade 4 toxicity occurred. Our study suggests that further investigations concerning the use of IMRT to treat cancer of the anus are warranted. IMRT makes it possible to remove the gap, but with no impact on the prognosis. Nonetheless, a longer follow-up is essential to determine whether or not IMRT has an impact on late toxicity, local control and survival compared with conventional 3D-CRT

  6. Estimate of the damage in organs induced by neutrons in three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Benites R, J. L.; Vega C, H. R.; Uribe, M. del R.

    2014-08-01

    By means of Monte Carlo methods was considered the damage in the organs, induced by neutrons, of patients with cancer that receive treatment in modality of three-dimensional conformal radiotherapy (3D-CRT) with lineal accelerator Varian Ix. The objective of this work was to estimate the damage probability in radiotherapy patients, starting from the effective dose by neutrons in the organs and tissues out of the treatment region. For that a three-dimensional mannequin of equivalent tissue of 30 x 100 x 30 cm 3 was modeled and spherical cells were distributed to estimate the Kerma in equivalent tissue and the absorbed dose by neutrons. With the absorbed dose the effective dose was calculated using the weighting factors for the organ type and radiation type. With the effective dose and the damage factors, considered in the ICRP 103, was considered the probability of damage induction in organs. (Author)

  7. Prospective randomized trail on chrono-chemotherapy + late course three dimensional conformal radio-therapy and conventional chemotherapy plus radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Jin Feng; Ouyang Jinling; Dong Hongmin; Wu Weili; Chen Haixia; He Zhihui

    2005-01-01

    Objective: To compare the therapeutic effects, toxic side effects of late-course three dimensional conformal radiotherapy plus chrono-chemotherapy (DDP + 5-FU/CF) and conventional radiotherapy plus chemotherapy for nasopharyngeal carcinoma (NPC). Methods: Eighty -six NPC patients admitted from Feb. 2001 to Jan. 2002 were divided randomly into two groups: 1. Chrono-chemotherapy + late course three dimensional conformal radiotherapy(CCR) group-44 patients were treated by late course three dimensional conformal radio-therapy plus chrono-chemotherapy, and 2. Routine-chemotherapy-radiotherapy (RCR) group-42 patients were treated by routine chemotherapy plus radiotherapy. The patients in CCR and RCR group were comparable in age, KPS, stage and pathology. All patients were treated by combined chemotherapy and radiotherapy, with chemotherapy stared 2 weeks ahead of radiotherapy. Chemotherapy: Braun pump was used in all drug infusions; 1. CCR group-DDP 80 mg/ m 2 starting from 10:00 until 22:00, 5-Fu 750 mg/d/m 2 starting from 22:00 until 10:00 next day, CF 200 mg/d/m 2 starting from 10:00 every day, infused at normal speed. These drugs were given for 3 days, 14 days as one cycle, totally 2 cycle, and 2. RCR group-with the same drugs at the same total dose, only with the difference being DDP and CF given QD, starting from 10:00 but at the normal speed. 5-Fu was given through-out the day and continuously for 3 days, totally for 2 cycles. Radiotherapy: linear accelerator irradiation was given to either group. Composite facio-cervical field + anterior cervical tangential field to D T 40 Gy/4w, followed by the coned down per-auricular field plus anterior tangential field or β beam irradiation. In CCR group, after D T 40gy/4w, late course 3-dimensional conformal radiotherapy (3DCRT) was used to add D T 30Gy/3w. In RCR group, routine radiotherapy of 40 Gy/w was supplemented with 30 Gy/3w. The total dose in either group was 70 Gy/7w at the nasopharynx, D T 60-70 Gy/6-7w at the

  8. Dosimetric Advantage of Intensity-Modulated Radiotherapy for Whole Ventricles in the Treatment of Localized Intracranial Germinoma

    International Nuclear Information System (INIS)

    Sakanaka, Katsuyuki; Mizowaki, Takashi; Hiraoka, Masahiro

    2012-01-01

    Purpose: To investigate the dosimetric advantage of intensity-modulated radiotherapy (IMRT) for whole ventricles (WV) in patients with a localized intracranial germinoma receiving induction chemotherapy. Methods and Materials: Data from 12 consecutive patients with localized intracranial germinomas who received induction chemotherapy and radiotherapy were used. Four-field coplanar three-dimensional conformal radiotherapy (3D-CRT) and seven-field coplanar IMRT plans were created. In both plans, 24 Gy was prescribed in 12 fractions for the planning target volume (PTV) involving WV and tumor bed. In IMRT planning, optimization was conducted to reduce the doses to the organs at risk (OARs) as much as possible, keeping the minimum dose equivalent to that of 3D-CRT. The 3D-CRT and IMRT plans were compared in terms of the dose–volume statistics for target coverage and the OARs. Results: IMRT significantly increased the percentage volume of the PTV receiving 24 Gy compared with 3D-CRT (93.5% vs. 84.8%; p = 0.007), while keeping target homogeneity equivalent to 3D-CRT (p = 0.869). The absolute percentage reduction in the irradiated volume of the normal brain receiving 100%, 75%, 50%, and 25% of 24 Gy ranged from 0.7% to 16.0% in IMRT compared with 3D-CRT (p < 0.001). No significant difference was observed in the volume of the normal brain receiving 10% and 5% of 24 Gy between IMRT and 3D-CRT. Conformation number was significantly improved in IMRT (p < 0.001). For other OARs, the mean dose to the cochlea was reduced significantly in IMRT by 22.3% of 24 Gy compared with 3D-CRT (p < 0.001). Conclusions: Compared with 3D-CRT, IMRT for WV improved the target coverage and reduced the irradiated volume of the normal brain in patients with intracranial germinomas receiving induction chemotherapy. IMRT for WV with induction chemotherapy could reduce the late side effects from cranial irradiation without compromising control of the tumor.

  9. Can All Centers Plan Intensity-Modulated Radiotherapy (IMRT) Effectively? An External Audit of Dosimetric Comparisons Between Three-Dimensional Conformal Radiotherapy and IMRT for Adjuvant Chemoradiation for Gastric Cancer

    International Nuclear Information System (INIS)

    Chung, Hans T.; Lee, Brian; Park, Eileen; Lu, Jiade J.; Xia Ping

    2008-01-01

    Purpose: To compare dosimetric endpoints between three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) at our center with limited IMRT experience, and to perform an external audit of the IMRT plans. Methods and Materials: Ten patients, who received adjuvant chemoradiation for gastric cancer, formed the study cohort. For standardization, the planning target volume (PTV) and organs at risk were recontoured with the assistance of a study protocol radiologic atlas. The cohort was replanned with CMS Xio to generate coplanar 3D-CRT and IMRT plans. All 10 datasets, including volumes but without the plans (i.e., blinded), were transmitted to an experienced center where IMRT plans were designed using Nomos Corvus (IMRT-C) and ADAC Pinnacle (IMRT-P). All IMRT plans were normalized to D95% receiving 45 Gy. Results: Intensity-modulated radiotherapy yielded higher PTV V45 (volume that receives ≥45 Gy) (p < 0.001) than 3D-CRT. No difference in V20 was seen in the right (p = 0.9) and left (p 0.3) kidneys, but the liver mean dose (p < 0.001) was superior with IMRT. For the external audit, IMRT-C (p = 0.002) and IMRT-P (p < 0.001) achieved significantly lower left kidney V20 than IMRT, and IMRT-P (p < 0.001) achieved lower right kidney V20 than IMRT. The IMRT-C (p = 0.003) but not IMRT-P (p = 0.6) had lower liver mean doses than IMRT. Conclusions: At our institution with early IMRT experience, IMRT improved PTV dose coverage and liver doses but not kidney doses. An external audit of IMRT plans showed that an experienced center can yield superior IMRT plans

  10. Volumetric intensity-modulated arc therapy vs. 3-dimensional conformal radiotherapy for primary chemoradiotherapy of anal carcinoma. Effects on treatment-related side effects and survival

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Hanne Elisabeth; Droege, Leif Hendrik; Hennies, Steffen; Herrmann, Markus Karl; Wolff, Hendrik Andreas [University Medical Center Goettingen, Dept. of Radiotherapy and Radiooncology, Goettingen (Germany); Gaedcke, Jochen [University Medical Center Goettingen, Dept. of General Surgery, Goettingen (Germany)

    2015-11-15

    Primary chemoradiotherapy (CRT) is the standard treatment for locally advanced anal carcinoma. This study compared volumetric intensity-modulated arc therapy (VMAT) to 3-dimensional conformal radiotherapy (3DCRT) in terms of treatment-related side effects and survival. From 1992-2014, 103 consecutive patients with anal carcinoma UICC stage I-III were treated. Concomitant CRT consisted of whole pelvic irradiation, including the iliac and inguinal lymph nodes, with 50.4 Gy (1.8 Gy per fractions) by VMAT (n = 17) or 3DCRT (n = 86) as well as two cycles of 5-fluorouracil and mitomycin C. Acute organ and hematological toxicity were assessed according to the Common Terminology Criteria (CTC) for Adverse Events version 3.0. Side effects ≥ grade 3 were scored as high-grade toxicity. High-grade acute organ toxicity CTC ≥ 3 (P < 0.05), especially proctitis (P = 0.03), was significantly reduced in VMAT patients. The 2-year locoregional control (LRC) and disease-free survival (DFS) were both 100 % for VMAT patients compared with 80 and 73 % for 3DCRT patients. VMAT was shown to be a feasible technique, achieving significantly lower rates of acute organ toxicity and promising results for LRC and DFS. Future investigations will aim at assessing the advantages of VMAT with respect to late toxicity and survival after a prolonged follow-up time. (orig.) [German] Die primaere Radiochemotherapie (RCT) gilt als Standardtherapie fuer lokal fortgeschrittene Analkarzinome. In dieser Studie wurde die volumetrisch modulierte Rotationstherapie (''volumetric intensity-modulated arc therapy'', VMAT) mit der klassischen dreidimensionalen konformalen Radiotherapie (3DCRT) hinsichtlich therapieassoziierter Nebenwirkungen und Ueberleben verglichen. Von 1992-2014 wurden 103 aufeinanderfolgende Patienten mit einem Analkarzinom im UICC-Stadium I-III behandelt. Die kombinierte RCT bestand aus der Bestrahlung des gesamten Beckens inklusive der iliakalen und der inguinalen

  11. Geometrical uncertainty margins in 3D conformal radiotherapy in the pediatric age group

    International Nuclear Information System (INIS)

    Eldebawy, E.; Attalla, E.; Eldesoky, I.; Zaghloul, M.S.

    2011-01-01

    To evaluate set-up variation of pediatric patients undergoing 3D conformal radiotherapy (3DCRT) using electronic portal image device (EPID), in an effort to evaluate the adequacy of the planning target volume (PTV) margin employed for the 3DCRT treatment of pediatric patients. Materials and methods: Set-up data was collected from 48 pediatric patients treated with 3D CRT-for head and neck (31 patients), abdomino-pelvic (9 patients) and chest (8 patients) sites during the period between September 2008 and February 2009. A total of 358 images obtained by EPID were analyzed. The mean (M) and standard deviation (SD) for systematic and random errors were calculated and the results were analyzed. Results: All images were studied in anterior and lateral portals. The systematic errors along longitudinal, lateral and vertical directions in all patients showed an M equal to 1.9,1.6, and 1.6 mm with SD of 1.8,1.4, and 1.8 mm, respectively; (head and neck cases: M equal to 1.5,1.2, and 1.6 mm with SD 1.4,1.2, and 1.8 mm; chest cases: M equal to 2.5,1.8, and 0.8 mm with SD 2.7,1.7, and 1.2 mm, abdomen-pelvic cases: M equal to 2.9,2.8 and 2.3 mm with SD 1.6,1.2, and 2.3 mm). Similarly, the random errors for all patients showed SD of 1.9,1.6, and 1.8 mm, respectively (head and neck cases: SD 1.7,1.3, and 1.5 mm; chest cases: SD 1.2,1.9, and 2.5 mm; abdomino-pelvic cases SD 2.5, 2, and 2.4 mm, respectively). Using Van Herk's formula the suggested (PTV) margin around the clinical target volume (CTV) of 5.5 mm appears to be adequate. Conclusion: The ranges of set-up errors are site specific and depends on many factors

  12. Sexual Function After Three-Dimensional Conformal Radiotherapy for Prostate Cancer: Results From a Dose-Escalation Trial

    International Nuclear Information System (INIS)

    Wielen, Gerard J. van der; Putten, Wim van; Incrocci, Luca

    2007-01-01

    Purpose: The purpose of this study is to provide information about sexual function (SF) after three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer while taking important factors into account that influence SF. Methods and Materials: Between June 1997 and February 2003, a total of 268 patients from a randomized dose-escalation trial comparing 68 Gy and 78 Gy agreed to participate in an additional part of the trial that evaluated SF. Results: At baseline 28% of patients had erectile dysfunction (ED). After 1 year, 27% of the pretreatment potent patients had developed ED. After 2 years this percentage had increased to 36%. After 3 years it almost stabilized at 38%. Satisfaction with sexual life was significantly correlated with ED. After 2 years one third of the pre-treatment potent patients still had considerable to very much sexual desire and found sex (very) important. No significant differences were found between the two dose-arms. Potency aids were used on a regular base by 14% of the patients. Conclusion: By taking adjuvant hormonal therapy (HT), HT during follow-up and potency aids into account, we found a lower percentage of ED after 3D-CRT than reported in previous prospective studies. A large group of patients still had sexual desire, considered sex important and 14% used potency aids after 3D-CRT

  13. Predictive factors of gastroduodenal toxicity in cirrhotic patients after three-dimensional conformal radiotherapy for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kim, Haeyoung; Lim, Do Hoon; Paik, Seung Woon; Yoo, Byung Chul; Koh, Kwang Gheol; Lee, Joon Hyoek; Choi, Moon Seok; Park, Won; Park, Hee Chul; Huh, Seung Jae; Choi, Doo Ho; Ahn, Yong Chan

    2009-01-01

    Background and purpose: To identify predictive factors for the development of gastroduodenal toxicity (GDT) in cirrhotic patients treated with three-dimensional conformal radiotherapy (3D-CRT) for hepatocellular carcinoma (HCC). Materials and methods: We retrospectively analyzed dose-volume histograms (DVHs) and clinical records of 73 cirrhotic patients treated with 3D-CRT for HCC. The median radiation dose was 36 Gy (range, 30-54 Gy) with a daily dose of 3 Gy. The grade of GDT was defined by the Common Toxicity Criteria Version 2. The predictive factors of grade 3 GDT were identified. Results: Grade 3 GDT was found in 9 patients. Patient's age and the percentage of gastroduodenal volume receiving more than 35 Gy (V 35 ) significantly affected the development of grade 3 GDT. Patients over 50 years of age developed grade 3 GDT more frequently than patients under 50 years of age. The risk of grade 3 GDT grew exponentially as V 35 increased. The 1-year actuarial rate of grade 3 GDT in patients with V 35 35 ≥5% (4% vs. 48%, p 35 were the most predictive factors for the development of grade 3 GDT in patients treated with RT.

  14. Transition from 2-D radiotherapy to 3-D conformal and intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    2008-05-01

    Cancer is one of the leading causes of death globally and radiotherapy is currently an essential component in the management of cancer patients, either alone or in combination with surgery or chemotherapy, both for cure or palliation. It is now recognized that safe and effective radiotherapy service needs not only substantial capital investment in radiotherapy equipment and specially designed facilities but also continuous investment in maintenance and upgrading of the equipment to comply with the technical progress, but also in training the staff. The recent IAEA-TECDOC publication 'Setting up a Radiotherapy Programme: Clinical, Medical Physics, Radiation Protection and Safety Aspects' provides general guidelines for designing and implementing radiotherapy services in Member States. Advances in computer technology have enabled the possibility of transitioning from basic 2- dimensional treatment planning and delivery (2-D radiotherapy) to a more sophisticated approach with 3-dimensional conformal radiotherapy (3-D CRT). Whereas 2-D radiotherapy can be applied with simple equipment, infrastructure and training, transfer to 3-D conformal treatments requires more resources in technology, equipment, staff and training. A novel radiation treatment approach using Intensity Modulated Radiation Therapy (IMRT) that optimizes the delivery of radiation to irregularly shaped tumour volumes demands even more sophisticated equipment and seamless teamwork, and consequentially more resources, advanced training and more time for treatment planning and verification of dose delivery than 3-D CRT. Whereas 3-D CRT can be considered as a standard, IMRT is still evolving. Due to the increased interest of Member States to the modern application of radiotherapy the IAEA has received a number of requests for guidance coming from radiotherapy departments that wish to upgrade their facilities to 3-D CRT and IMRT through Technical Cooperation programme. These requests are expected to increase

  15. Analysis of Biochemical Control and Prognostic Factors in Patients Treated With Either Low-Dose Three-Dimensional Conformal Radiation Therapy or High-Dose Intensity-Modulated Radiotherapy for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Vora, Sujay A.; Wong, William W.; Schild, Steven E.; Ezzell, Gary A.; Halyard, Michele Y.

    2007-01-01

    Purpose: To identify prognostic factors and evaluate biochemical control rates for patients with localized prostate cancer treated with either high-dose intensity-modulated radiotherapy (IMRT) or conventional-dose three-dimensional conformal radiotherapy 3D-CRT. Methods: Four hundred sixteen patients with a minimum follow-up of 3 years (median, 5 years) were included. Two hundred seventy-one patients received 3D-CRT with a median dose of 68.4 Gy (range, 66-71 Gy). The next 145 patients received IMRT with a median dose of 75.6 Gy (range, 70.2-77.4 Gy). Biochemical control rates were calculated according to both American Society for Therapeutic Radiology and Oncology (ASTRO) consensus definitions. Prognostic factors were identified using both univariate and multivariate analyses. Results: The 5-year biochemical control rate was 60.4% for 3D-CRT and 74.1% for IMRT (p < 0.0001, first ASTRO Consensus definition). Using the ASTRO Phoenix definition, the 5-year biochemical control rate was 74.4% and 84.6% with 3D-RT and IMRT, respectively (p = 0.0326). Univariate analyses determined that PSA level, T stage, Gleason score, perineural invasion, and radiation dose were predictive of biochemical control. On multivariate analysis, dose, Gleason score, and perineural invasion remained significant. Conclusion: On the basis of both ASTRO definitions, dose, Gleason score, and perineural invasion were predictive of biochemical control. Intensity-modulated radiotherapy allowed delivery of higher doses of radiation with very low toxicity, resulting in improved biochemical control

  16. Design and implementation of a rotational radiotherapy technique for breast cancer treatment and their comparison with 3-D-Crt irradiation technique

    International Nuclear Information System (INIS)

    Gutierrez M, J. G.; Lopez V, A.; Rivera M, T.; Velazquez T, J. J.; Adame G, C. S.; Rubio N, O.; Chagoya G, A.; Hernandez G, J. C.

    2015-10-01

    Breast cancer is one of oncological diseases worldwide, as well in Mexico, which causes even more deaths than cervical cancer; this condition is the second death cause in women aged 30-54 years and threatens all socio-economic groups. The treatment is highly dependent on the stage which is detected and based on protocols that include a combination of surgery, chemotherapy and radiotherapy. This paper studies the main irradiation technique for patients with mastectomy, breast full cycle (irradiation of the chest well and supraclavicular nodes) in their mode Three Dimensional - Conformal Radiation Therapy (3-D-Crt), and compared with the Volumetric Modulated Arc Therapy (VMAT) technique proposed in this paper. In both techniques the prescription was 50 Gy divided into 25 fractions. The techniques were applied in three female patients (being an initial study) with disease of the left side, the target volume and organs at risk were delineated by the medical treating radiation oncologist, the planning system used was Eclipse version 10; for quantitative comparison of both plans indexes of homogeneity were used, con formality, the target volume coverage and normal tissue, sub factors and overdosing, the conformation number and coverage quality. They were evaluated and compared the media, maximum and minimum dose of the organs at risk, based on the fact that the coverage of the target volume, dose gradient and dose at risk organs are acceptable (prescription dose greater that 90% coverage, gradient less that 20% and organs at risk in accordance with the Quantec limitations for both versions). (Author)

  17. [Technique of complex mammary irradiation: Mono-isocentric 3D conformational radiotherapy and helical tomotherapy].

    Science.gov (United States)

    Vandendorpe, B; Guilbert, P; Champagne, C; Antoni, T; Nguyen, T D; Gaillot-Petit, N; Servagi Vernat, S

    2017-12-01

    To evaluate the dosimetric contribution of helical tomotherapy for breast cancers compared with conformal radiotherapy in mono-isocentric technique. For 23 patients, the dosimetric results in mono-isocentric 3D conformational radiotherapy did not satisfy the constraints either of target volumes nor organs at risk. A prospective dosimetric comparison between mono-isocentric 3D conformational radiotherapy and helical tomotherapy was therefore carried out. The use of helical tomotherapy showed a benefit in these 23 patients, with either an improvement in the conformity index or homogeneity, but with an increase in low doses. Of the 23 patients, two had pectus excavatum, five had past thoracic irradiation and two required bilateral irradiation. The other 14 patients had a combination of morphology and/or indication of lymph node irradiation. For these patients, helical tomotherapy was therefore preferred to mono-isocentric 3D conformational radiotherapy. Tomotherapy appears to provide better homogeneity and tumour coverage. This technique of irradiation may be justified in the case of morphological situations such as pectus exavatum and in complex clinical situations. In other cases, conformal radiotherapy in mono-isocentric technique remains to be favoured. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  18. Intensity-modulated radiotherapy -the State of the Art

    International Nuclear Information System (INIS)

    Ling, C.

    2002-01-01

    Full text: In the last two decades of the last century, the development of three-dimensional conformal radiotherapy (3D-CRT) has substantially reduces the volume of critical organs irradiated to high doses, and has permitted the increase of tumor dose without concomitant increase in normal tissue complication. At Memorial Sloan Kettering Cancer Center, a clinical trial in cancer of the prostate has accrued >1600 patient and the prescription dose has been escalated to 81 Gy with 3D-CRT, and to 86.4 Gy using intensity modulated radiotherapy (IMRT), with promising results. 3D-CRT and IMRT involves the delineation of target and non-target structures from patient-specific 3D image data-sets (primarily CT, sometimes supplemented with MRI, PET etc.), the calculation and display of 3D dose distributions, the analysis and evaluation of structure-specific dose-volume data (DVH-dose volume histogram), radiation delivery with computer-controlled multileaf collimators (MLC), and treatment verification with electronic portal images. However, the dose distribution conformality achieved with 3D-CRT can be further improved by the use of computer-optimized IMRT. In addition, the treatment design phase of 3D-CRT involves several iterative steps and can be time-consuming, particularly when the anatomical geometry is complex. Thus, IMRT is an incremental advance from 3D-CRT with two key enhancements: 1) computerized iterative treatment plan optimization, and 2) the use of intensity-modulated radiation beams. To deliver the IM beams, one efficacious approach is to use MLC in the dynamic mode, using the so-called sliding-window technique, i.e. the leaves of the MLC are in motion while the radiation is being delivered. Since 1995, we have treated over 1500 patients with IMRT. This discussion shall describe the physical aspects of IMRT, emphasizing those features and benefits unique to this approach. Pertinent clinical results will also be briefly presented

  19. Strategies to evaluate the impact of rectal volume on prostate motion during three-dimensional conformal radiotherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Ana Paula Diniz Fortuna Poli

    2016-02-01

    Full Text Available Abstract Objective: To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT for prostate cancer. Materials and Methods: Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results: The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation ( p = 0.037. A baseline rectal volume superior to 70 cm3 had a significant influence on the prostate motion in the anteroposterior direction ( p = 0.045. Conclusion: The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm3. Therefore, the treatment of patients with a rectal volume > 70 cm3 should be re-planned with appropriate rectal preparation.

  20. Estimate of the damage in organs induced by neutrons in three-dimensional conformal radiotherapy; Estimacion del dano en organos inducido por neutrones en radioterapia conformada en 3D

    Energy Technology Data Exchange (ETDEWEB)

    Benites R, J. L. [Centro Estatal de Cancerologia de Nayarit, Servicio de Seguridad Radiologica, Calzada de la Cruz 118 sur, 63000 Tepic, Nayarit (Mexico); Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Uribe, M. del R., E-mail: jlbenitesr@prodigy.net.mx [Instituto Tecnico Superior de Radiologia, Calle Leon No. 129, 63000 Tepic, Nayarit (Mexico)

    2014-08-15

    By means of Monte Carlo methods was considered the damage in the organs, induced by neutrons, of patients with cancer that receive treatment in modality of three-dimensional conformal radiotherapy (3D-CRT) with lineal accelerator Varian Ix. The objective of this work was to estimate the damage probability in radiotherapy patients, starting from the effective dose by neutrons in the organs and tissues out of the treatment region. For that a three-dimensional mannequin of equivalent tissue of 30 x 100 x 30 cm{sup 3} was modeled and spherical cells were distributed to estimate the Kerma in equivalent tissue and the absorbed dose by neutrons. With the absorbed dose the effective dose was calculated using the weighting factors for the organ type and radiation type. With the effective dose and the damage factors, considered in the ICRP 103, was considered the probability of damage induction in organs. (Author)

  1. Conformal radiotherapy: principles and classification

    International Nuclear Information System (INIS)

    Rosenwald, J.C.; Gaboriaud, G.; Pontvert, D.

    1999-01-01

    'Conformal radiotherapy' is the name fixed by usage and given to a new form of radiotherapy resulting from the technological improvements observed during the last ten years. While this terminology is now widely used, no precise definition can be found in the literature. Conformal radiotherapy refers to an approach in which the dose distribution is more closely 'conformed' or adapted to the actual shape of the target volume. However, the achievement of a consensus on a more specific definition is hampered by various difficulties, namely in characterizing the degree of 'conformality'. We have therefore suggested a classification scheme be established on the basis of the tools and the procedures actually used for all steps of the process, i.e., from prescription to treatment completion. Our classification consists of four levels: schematically, at level 0, there is no conformation (rectangular fields); at level 1, a simple conformation takes place, on the basis of conventional 2D imaging; at level 2, a 3D reconstruction of the structures is used for a more accurate conformation; and level 3 includes research and advanced dynamic techniques. We have used our personal experience, contacts with colleagues and data from the literature to analyze all the steps of the planning process, and to define the tools and procedures relevant to a given level. The corresponding tables have been discussed and approved at the European level within the Dynarad concerted action. It is proposed that the term 'conformal radiotherapy' be restricted to procedures where all steps are at least at level 2. (author)

  2. A retrospective comparison of outcome and toxicity of preoperative image-guided intensity-modulated radiotherapy versus conventional pelvic radiotherapy for locally advanced rectal carcinoma

    International Nuclear Information System (INIS)

    Huang, Chun-Ming; Huang, Ming-Yii; Tsai, Hsiang-Lin; Huang, Ching-Wen; Ma, Cheng-Jen; Lin, Chih-Hung; Huang, Chih-Jen; Wang, Jaw-Yuan

    2017-01-01

    The aim of the study was to compare clinical outcomes and toxicity between 3D conformal radiotherapy (3DCRT) and image-guided intensity-modulated radiotherapy (IG-IMRT) administered through helical tomotherapy in locally advanced rectal cancer (LARC) patients receiving preoperative chemoradiotherapy. We reviewed 144 patients with Stage II–III rectal cancer receiving preoperative fluoropyrimidine-based chemoradiotherapy followed by radical resection. Tumor responses following chemoradiotherapy were evaluated using the Dworak tumor regression grade (TRG). Of the 144 patients, 45 received IG-IMRT and 99 received 3DCRT. A significant reduction in Grade 3 or 4 acute gastrointestinal toxicity (IG-IMRT, 6.7%; 3DCRT, 15.1%; P = 0.039) was observed by IG-IMRT. The pathologic complete response (pCR) rate did not differ between the IG-IMRT and the 3DCRT group (17.8% vs 15.1%, P = 0.52). Patients in the IG-IMRT group had the trend of favorable tumor regressions (TRG 3 or 4) compared with those in the 3DCRT group (66.7% vs 43.5%, P = 0.071). The median follow-up was 53 months (range, 18–95 months) in the 3DCRT group and 43 months (range, 17–69 months) in the IG-IMRT group. Four-year overall, disease-free, and local failure–free survival rates of the IG-IMRT and 3DCRT groups were 81.6% and 67.9% (P = 0.12), 53.8% and 51.8% (P = 0.51), and 88% and 75.1% (P = 0.031), respectively. LARC patients treated with preoperative IG-IMRT achieved lower acute gastrointestinal adverse effects and a higher local control rate than those treated with 3DCRT, but there was no prominent difference in distant metastasis rate and overall survival between two treatment modalities.

  3. Neoadjuvant androgen deprivation and prostate gland shrinkage during conformal radiotherapy

    International Nuclear Information System (INIS)

    Sanguineti, Giuseppe; Marcenaro, Michela; Franzone, Paola; Foppiano, Franca; Vitale, Vito

    2003-01-01

    Purpose: The shrinking effect of 3-month neoadjuvant androgen deprivation (NAD) on preradiotherapy prostate gland volume is well documented. However, recently, it has been shown that the cancerous prostate gland keeps shrinking up to 12 months after NAD start. Thus, if such a reduction is not taken into account, a larger than planned portion of the surrounding normal tissues might shift in the high-dose region during conformal radiotherapy (3DCRT) course. The present study was undertaken to quantify this issue. Materials and Methods: Prostate gland volume reduction between planning CT (plCT) and the last week of 3DCRT (tmtCT) was prospectively assessed in 33 consecutive patients with localized prostate carcinoma. The median time interval between plCT and tmtCT was 2.5 months (2.1-2.7 months). A single observer was asked to draw on each slice prostate gland volume as appropriate. The observer was 'blind' to the timing of CT (plCT vs. tmtCT). In order to estimate intra-observer variability, prostate gland delineation was repeated twice for each data set. Mean prostate gland change, plCT and tmtCT cumulative dose volume histogram (DVH) calculations for the rectum were analyzed for each patient. Results were correlated to AD status and its duration before plCT. Means were compared by non-parametric rank tests. Results: Based on an internal protocol, 14 patients (42%) did not receive AD, while 19 patients (58%) had undergone neoadjuvant and concomitant AD. The median duration of AD before plCT ranged from 0.2 to 6 months (median: 2.9 months). Although individual data were highly variable, compared to plCT volume, mean prostate gland volume change at the end of 3DCRT was similar for patients receiving (-7.3%) or not (-7%) androgen deprivation (P=0.77). However, within the group of patients treated with hormones, patients starting AD within 3 months from plCT had a significantly larger reduction in prostate volume (-14.2%) than patients with longer NAD duration (-1.1%, P

  4. A Comparative Dosimetric Study of Adjuvant 3D Conformal Radiotherapy for Operable Stomach Cancer Versus AP-PA Conventional Radiotherapy in NCI-Cairo

    International Nuclear Information System (INIS)

    El-Hossiny, H.A.; Diab, N.A.; El-Taher, M.M.

    2009-01-01

    This study was to compare this multiple field conformal technique to the AP-PA technique with respect to target volume coverage and dose to normal tissues. Materials and Methods: Seventeen patients with stages II-III denocarcinoma of the stomach were treated with adjuvant postoperative chemoradiotherapy presented to radiotherapy department in National Cancer Institute, Cairo in period between February 2009 to March 2010 using 3D conformal radiotherapy technique that consisted of a mono isocentric arrangement employing 4-6 radiation fields. For each patient, a second radiotherapy treatment plan was done using an antroposterior (AP-PA) fields, the two techniques were then compared using dose volume histogram (DVH) analysis. Results: Comparing different DVHs, it was found that the planning target volume (PTV) was adequately covered in both (3D and 2D) plans while the left kidney and spinal cord demonstrate lower radiation doses on using the conformal technique. The liver doses is higher in the 3D tecq, but still well below liver tolerance. Conclusions: Both 3D conformal radiotherapy and AP-PA conventional techniques doses are within range of normal tissues tolerance. Regarding the left kidney and spinal cord the 3D conformal radiotherapy is superior than the AP-PA conventional techniques but with higher doses to the liver in the 3D conformal radiotherapy compared to the AP-PA conventional techniques

  5. Clinical Applications of 3-D Conformal Radiotherapy

    Science.gov (United States)

    Miralbell, Raymond

    Although a significant improvement in cancer cure (i.e. 20% increment) has been obtained in the last 2-3 decades, 30-40% of patients still fail locally after curative radiotherapy. In order to improve local tumor control rates with radiotherapy high doses to the tumor volume are frequently necessary. Three-dimensional conformal radiation therapy (3-D CRT) is used to denote a spectrum of radiation planning and delivery techniques that rely on three-dimensional imaging to define the target (tumor) and to distinguish it from normal tissues. Modern, high-precision radiotherapy (RT) techniques are needed in order to implement the goal of optimal tumor destruction delivering minimal dose to the non-target normal tissues. A better target definition is nowadays possible with contemporary imaging (computerized tomography, magnetic resonance imaging, and positron emission tomography) and image registration technology. A highly precise dose distributions can be obtained with optimal 3-D CRT treatment delivery techniques such as stereotactic RT, intensity modulated RT (IMRT), or protontherapy (the latter allowing for in-depth conformation). Patient daily set-up repositioning and internal organ immobilization systems are necessary before considering to undertake any of the above mentioned high-precision treatment approaches. Prostate cancer, brain tumors, and base of skull malignancies are among the sites most benefitting of dose escalation approaches. Nevertheless, a significant dose reduction to the normal tissues in the vicinity of the irradiated tumor also achievable with optimal 3-D CRT may also be a major issue in the treatment of pediatric tumors in order to preserve growth, normal development, and to reduce the risk of developing radiation induced diseases such as cancer or endocrinologic disorders.

  6. Metastatic breast cancer in the eye and orbit, use three-dimensional conformal radiotherapy. Our first experience

    International Nuclear Information System (INIS)

    Correa Pablos, Tamara; Caceres Toledo, Maria

    2009-01-01

    The eye and orbit metastases are a significant clinical problem, both by the inability and the deterioration in the quality of life that occur. The most common malignant tumors in the eye and orbit is metastasis. Cancer breast cancer is the most common tumor metastatic to the eye and orbit in a 40% and 50% of cases according to different series. With the introduction of Three-Dimensional Conformal Radiotherapy (3D-CRT) in our hospital from In 2007 we were able to treat patients with cancer different regions with the technique (2D) was impossible because caused irreparable damage to surrounding healthy tissue in this way thanks to potential of 3D technology to shape the planning volume will ensure greater protection for critical organs. (Author)

  7. Domestic comparison of radiation treatment techniques for breast cancer: 3D-CRT, IMRT and VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bo Ram; Yoon, Myong Geun [Dept. of Bio-convergence Engineering, College of Health Science, Korea University, Seoul (Korea, Republic of); Lee, Sun Young [Dept. of Radiation Oncology, Yusung Sun Medical Center, Daejeon (Korea, Republic of)

    2013-09-15

    The purpose of this study is to compare method in the treatment of breast cancer using dose index. And, it is to find the optimized treatment technique to the patient. The phantom filled with tissue-equivalent material were used simulation and treatment as techniques of 3D-CRT, IMRT, VMAT was planned using Eclipse v10. By using HI(homogeneity index), CI(Conformity index), OE (Organ equivalent dose), EAR(Excess Absolute Risk), were assessed for each treatment plans. HI and CI of 3D-CRT, IMRT, VMAT were calculated 16.89, 11.21, 9.55 and 0.59, 0.61, 0.83. The organ average doses of Lt lung, Rt lung, liver, heart, esophagus, cord, Lt breast, trachea and stomach were 0.01 ∼ 2.02 Gy, 0.36 ∼ 5.01 Gy, 0.25 ∼ 2.49 Gy, 0.14 ∼ 6.92 Gy, 0.03 ∼ 2.02 Gy, 0.01 ∼ 1.06 Gy, 0.25 ∼ 6.08 Gy, 0.08 ∼ 0.59 Gy, 0.01 ∼ 1.34 Gy, respectively. The OED, EAR of the IMRT and VMAT show higher than 3D-CRT. As the result of this study, we could confirm being higher dose index(HI, CI) in IMRT and VMAT than 3D-CRT, but doses of around normal organs was higher IMRT, VMAT than 3D-CRT.

  8. Impact of Different CT Slice Thickness on Clinical Target Volume for 3D Conformal Radiation Therapy

    International Nuclear Information System (INIS)

    Prabhakar, Ramachandran; Ganesh, Tharmar; Rath, Goura K.; Julka, Pramod K.; Sridhar, Pappiah S.; Joshi, Rakesh C.; Thulkar, Sanjay

    2009-01-01

    The purpose of this study was to present the variation of clinical target volume (CTV) with different computed tomography (CT) slice thicknesses and the impact of CT slice thickness on 3-dimensional (3D) conformal radiotherapy treatment planning. Fifty patients with brain tumors were selected and CT scans with 2.5-, 5-, and 10-mm slice thicknesses were performed with non-ionic contrast enhancement. The patients were selected with tumor volume ranging from 2.54 cc to 222 cc. Three-dimensional treatment planning was performed for all three CT datasets. The target coverage and the isocenter shift between the treatment plans for different slice thickness were correlated with the tumor volume. An important observation from our study revealed that for volume 25 cc, the target underdosage was less than 6.7% for 5-mm slice thickness and 8% for 10-mm slice thickness. For 3D conformal radiotherapy treatment planning (3DCRT), a CT slice thickness of 2.5 mm is optimum for tumor volume 25 cc

  9. The evolution of rectal and urinary toxicity and immune response in prostate cancer patients treated with two three-dimensional conformal radiotherapy techniques

    International Nuclear Information System (INIS)

    Vranova, Jana; Vinakurau, Stepan; Richter, Jan; Starec, Miroslav; Fiserova, Anna; Rosina, Jozef

    2011-01-01

    Our research compared whole pelvic (WP) and prostate-only (PO) 3-dimensional conformal radiotherapy (3DCRT) techniques in terms of the incidence and evolution of acute and late toxicity of the rectum and urinary bladder, and identified the PTV-parameters influencing these damages and changes in antitumor immune response. We analyzed 197 prostate cancer patients undergoing 3DCRT for gastrointestinal (GI) and genitourinary (GU) toxicities, and conducted a pilot immunological study including flow cytometry and an NK cell cytotoxicity assay. Acute and late toxicities were recorded according to the RTOG and the LENT-SOMA scales, respectively. Univariate and multivariate analyses were conducted for factors associated with toxicity. In the WP group, an increase of acute rectal toxicity was observed. A higher incidence of late GI/GU toxicity appeared in the PO group. Only 18 patients (WP-7.76% and PO-11.11%) suffered severe late GI toxicity, and 26 patients (WP-11.21% and PO-16.05%) severe late GU toxicity. In the majority of acute toxicity suffering patients, the diminution of late GI/GU toxicity to grade 1 or to no toxicity after radiotherapy was observed. The 3DCRT technique itself, patient age, T stage of TNM classification, surgical intervention, and some dose-volume parameters emerged as important factors in the probability of developing acute and late GI/GU toxicity. The proportion and differentiation of NK cells positively correlated during 3DCRT and negatively so after its completion with dose-volumes of the rectum and urinary bladder. T and NKT cells were down-regulated throughout the whole period. We found a negative correlation between leukocyte numbers and bone marrow irradiated by 44-54 Gy and a positive one for NK cell proportion and doses of 5-25 Gy. The acute GU, late GU, and GI toxicities up-regulated the T cell (CTL) numbers and NK cytotoxicity. Our study demonstrates the association of acute and late damage of the urinary bladder and rectum, with

  10. Importance of protocol target definition on the ability to spare normal tissue: An IMRT and 3D-CRT planning comparison for intraorbital tumors

    International Nuclear Information System (INIS)

    Hein, Patrick A.; Gladstone, David J.; Bellerive, Marc R.; Hug, Eugen B.

    2005-01-01

    Purpose: We selected five intraorbital tumor sites that are frequently found in clinical practice in children diagnosed with orbital rhabdomyosarcoma and performed three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated photon radiotherapy (IMRT) planning. Results of target coverage and doses to critical structures were compared. The goal of this study was to evaluate and to document realistic expectations as to organ-sparing capabilities of modern radiation therapy planning technologies with a focus on lens-sparing irradiation. Furthermore, we investigated potential added benefits of IMRT compared with 3D-CRT and the influence of protocol volume criteria definitions on the ability to obtain normal tissue dose sparing using the orbit as an example of a complex anatomic site. Methods and Materials: The five intraorbital tumor sites were placed retrobulbar, temporal, nasal, in the upper inner and upper outer quadrant, the latter two more complex in shape. Gross tumor volume (GTV), clinical target volume (CTV), and planning target volume (PTV) were defined in image-fused computed tomography and magnetic resonance data sets. 3D-CRT and IMRT photon plans, using equal beam angles and collimation for direct comparison, were designed to 45 Gy prescription dose according to Intergroup Rhabdomyosarcoma Study Group-D9602 (IRSG-D9602) protocol (Intergroup Rhabdomyosarcoma Study V [IRS-V] protocol) for Stage I, Clinical Group 3 orbital rhabdomyosarcoma. To compare the impact of changed target definitions in IMRT planning, additional IMRT plans were generated using modified volume and dose coverage criteria. The minimum dose constraint (95%) of the PTV was substituted by a required minimum volume coverage (95%) with the prescribed dose. Dose-volume histograms (DVHs) were obtained, including target volumes, lens, optic nerves, optic chiasm, lacrimal gland, bony orbit, pituitary gland, frontal and temporal lobes. Results: Protocol target volume coverage criteria

  11. 3D Conformal radiotherapy for gastric cancer-results of a comparative planning study

    International Nuclear Information System (INIS)

    Leong, Trevor; Willis, David; Joon, Daryl Lim; Condron, Sara; Hui, Andrew; Ngan, Samuel Y.K.

    2005-01-01

    Background and purpose: Many radiation oncologists are reluctant to use anteroposterior-posteroanterior (AP-PA) field arrangements when treating gastric cancer with adjuvant postoperative radiotherapy due to concerns about normal tissue toxicity, particularly in relation to the kidneys and spinal cord. In this report, we describe a multiple-field conformal radiotherapy technique, and compare this technique to the more commonly used AP-PA technique that was used in the recently reported Intergroup study (INT0116). Materials and methods: Fifteen patients with stages II-IV adenocarcinoma of the stomach were treated with adjuvant postoperative chemoradiotherapy using a standardised 3D conformal radiotherapy technique that consisted of a 'split-field', mono-isocentric arrangement employing 6 radiation fields. For each patient, a second radiotherapy treatment plan was generated utilising AP-PA fields. The two techniques were then compared for target volume coverage and dose to normal tissues using dose volume histogram (DVH) analysis. Results: The conformal technique provides more adequate coverage of the target volume with 99% of the planning target volume (PTV) receiving 95% of the prescribed dose, compared to 93% using AP-PA fields. Comparative DVHs for the right kidney, left kidney and spinal cord demonstrate lower radiation doses using the conformal technique, and although the liver dose is higher, it is still well below liver tolerance. Conclusions: 3D conformal radiotherapy produces superior dose distributions and reduced radiation doses to the kidneys and spinal cord compared to AP-PA techniques, with the potential to reduce treatment toxicity

  12. Clinical application analysis of 3D-CRT methods using tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Kang Chul; Kyum, Hun Kyum; Kim, Joo Ho; Ahn, Seung Kwon; Lee, Sang Kyoo; Yoon, Jong Won; Cho, Jeong Hee [Dept. of Radiation Oncology, Yonsei Cancer Center, Yonsei University Health System, Seoul (Korea, Republic of); Lee, Jong Seok; Yoo, Beong Gyu [Dept. of Radiotechnology, Wonkwang Health Science University, Iksan (Korea, Republic of)

    2013-12-15

    This study investigates the case of clinical application for TomoDirect 3D-CRT(TD-3D) and TomoHelical 3D-CRT(TH-3D) with evaluating dose distribution for clinical application in each case. Treatment plans were created for 8 patients who had 3 dimensional conformal radiation therapy using TD-3D and TH-3D mode. Each patients were treated for sarcoma, CSI(craniospinal irradiation), breast, brain, pancreas, spine metastasis, SVC syndrome and esophagus. DVH(dose volume histogram) and isodose curve were used for comparison of each treatment modality. TD-3D shows better dose distribution over the irradiation field without junction effect because TD-3D was not influenced by target length for sarcoma and CSI case. In breast case, dosimetric results of CTV, the average value of D 99%, D 95% were 49.2±0.4 Gy, 49.9±0.4 Gy and V 105%, V 110% were 0%, respectively. TH-3D with the dosimetric block decreased dose of normal organ in brain, pancreas, spine metastasis case. SCV syndrome also effectively decreased dose of normal organ by using dose block to the critical organs(spinal cord <38 Gy). TH-3D combined with other treatment modalities was possible to boost irradiation and was total dose was reduced to spinal cord in esophagus case(spinal cord <45 Gy, lung V 20 <20%). 3D-CRT using Tomotherapy could overcomes some dosimetric limitations, when we faced Conventional Linac based CRT and shows clinically proper dose distribution. In conclusion, 3D-CRT using Tomotherapy will be one of the effective 3D-CRT techniques.

  13. Sucralfate versus mesalazine versus hydrocortisone in the prevention of acute radiation proctitis during conformal radiotherapy for prostate carcinoma. A randomized study.

    Science.gov (United States)

    Sanguineti, Giuseppe; Franzone, Paola; Marcenaro, Michela; Foppiano, Franca; Vitale, Vito

    2003-07-01

    To assess whether the topical use of steroids or 5-aminosalicylic acid (5-ASA) is superior to sucralfate in preventing acute rectal toxicity during three-dimensional conformal radiotherapy (3DCRT) to 76 Gy. Patients undergoing 3DCRT for prostate carcinoma at our institution were offered to be randomized to sucralfate 3 g in 15 ml suspension enema (Antepsin, mesalazine 4 g gel enema (Enterasyn, or hydrocortisone 100 mg foam enema (Colifoam. Randomization was blind to the treating physician but not to the patient. Sucralfate was chosen as control arm. Topical treatment had to be performed once daily, starting on day 1 of 3DCRT. Acute rectal toxicity was scored weekly according to RTOG criteria. Time to occurrence of grade 2+ acute rectal toxicity was taken as endpoint. The trial was opened in August 1999, and after the first 24 patients had been treated, arm 2 was discontinued because of eight patients receiving mesalazine, seven actually developed acute rectal toxicity (five patients grade 3 and two patients grade 2). Until May 2001, 134 consecutive patients were randomly assigned to sucralfate (63 patients), mesalazine (eight patients) or hydrocortisone (63 patients). The cumulative incidence of acute rectal toxicity at the end of treatment by arm is 61.9 +/- 6.1%, 87.5 +/- 11.7%, and 52.4 +/- 6.2% for arms 1, 2, and 3, respectively. The difference between the mesalazine group and the sucralfate group is highly significant (hazard ratio [HR] 2.5, 95% confidence interval [CI] 1.1-5.7; p = 0.03). At both uni- and multivariate analysis taking into account several patients and treatment covariates, the difference between hydrocortisone and sucralfate is not significant (HR 0.7, 95% CI 0.5-1.2; p = 0.2). Topical mesalazine is contraindicated during radiotherapy. Hydrocortisone enema is not superior to sucralfate in preventing acute rectal toxicity.

  14. Results of induction chemotherapy followed by three-dimensional conformal radiotherapy and concurrent weekly paclitaxel for stage III non-small cell lung cancer

    International Nuclear Information System (INIS)

    Wang Weihua; Bao Yong; Chen Ming; Zhang Li; Xu Guangchuan; Li Kaixin

    2008-01-01

    Objective: To evaluate the toxicity and efficacy of induction chemotherapy (ICT) followed by three-dimensional conformal radiotherapy (3DCRT) plus concurrent weekly paclitaxel for inoperable non-small cell lung cancer (NSCLC). Methods: Patients with stage III NSCLC in favorable conditions were treated with 2 to 4 cycles of carboplatin (AUC=5-6, d1) combined with paclitaxel (175 mg/m 2 , d1), then followed by weekly paclitaxel (40 mg/m 2 ) and concurrent 3DCRT within 34 weeks. The prescription dose of radiotherapy was given as high as possible while total lung V 20 ≤31% and total dose of the spinal cord ≤50 Gy. Results: ICT was well tolerated. During the concurrent chemoradiotherapy,the treatment of 4 patients was ended ahead of the schedule because of severe pulmonary and cardiac toxicities; the treatment of 2 patients was delayed for 7 and 12 days because of fatigue. Leucopenia(33/56) was in grade 1-2 except 1 patient in grade 3. Lymphocytopenia was severe (54/56,42 in grade 3). Three patients developed grade 3 acute radiation-induced esophagitis, and 3 developed grade 3-4 radiation-induced pneumonitis. There was one patients each who developed grade 2,3, and 4 late esophageal damage, respectively. Nine developed grade 2 pulmonary fibrosis. The overall response rate was 69.7%. The 1-year overall survival rate was 72.3%. The 1-year local progression-free survival rate was 62.7%. Conclusions: The schedule of ICT followed by weekly paclitaxel and concurrent 3DCRT can be well tolerated by most of the favorable patients with stage III NSCLC, and the toxicity is tolerable. Results of this study are encouraging, though long-term results should be followed up. (authors)

  15. Genital marginal failures after intensity-modulated radiation therapy (IMRT) in squamous cell anal cancer: no higher risk with IMRT when compared to 3DCRT.

    Science.gov (United States)

    Dell'Acqua, V; Kobiela, J; Kraja, F; Leonardi, M C; Surgo, A; Zerella, M A; Arculeo, S; Fodor, C; Ricotti, R; Zampino, M G; Ravenda, S; Spinoglio, G; Biffi, R; Bazani, A; Luraschi, R; Vigorito, S; Spychalski, P; Orecchia, R; Glynne-Jones, R; Jereczek-Fossa, B A

    2018-03-28

    Intensity-modulated radiotherapy (IMRT) is considered the preferred option in squamous cell canal cancer (SCAC), delivering high doses to tumor volumes while minimizing dose to surrounding normal tissues. IMRT has steep dose gradients, but the technique is more demanding as deep understanding of target structures is required. To evaluate genital marginal failure in a cohort of patients with non-metastatic SCAC treated either with IMRT or 3DCRT and concurrent chemotherapy, 117 patients with SCAC were evaluated: 64 and 53 patients were treated with IMRT and 3DCRT techniques, respectively. All patients underwent clinical and radiological examination during their follow-up. Tumor response was evaluated with response evaluation criteria in solid tumors v1.1 guideline on regular basis. All patients' data were analyzed, and patients with marginal failure were identified. Concomitant chemotherapy was administered in 97 and 77.4% of patients in the IMRT and 3DCRT groups, respectively. In the IMRT group, the median follow-up was 25 months (range 6-78). Progressive disease was registered in 15.6% of patients; infield recurrence, distant recurrence and both infield recurrence and distant recurrence were identified in 5, 4 and 1 patient, respectively. Two out of 64 patients (3.1%) had marginal failures, localized at vagina/recto-vaginal septum and left perineal region. In the 3DCRT group, the median follow-up was 71.3 months (range 6-194 months). Two out of 53 patients (3.8%) had marginal failures, localized at recto-vaginal septum and perigenital structures. The rate of marginal failures was comparable in IMRT and 3DCRT groups (χ 2 test p = 0.85). In this series, the use of IMRT for the treatment of SCAC did not increase the rate of marginal failures offering improved dose conformity to the target. Dose constraints should be applied with caution-particularly in females with involvement of the vagina or the vaginal septum.

  16. Acute gastrointestinal, genitourinary, and dermatological toxicity during dose-escalated 3D-conformal radiation therapy (3DCRT) using an intrarectal balloon for prostate gland localization and immobilization

    International Nuclear Information System (INIS)

    Woel, Rosemonde; Beard, Clair; Chen, Ming-Hui; Hurwitz, Mark; Loffredo, Marian; McMahon, Elizabeth; Ching, Jane; Lopes, Lynn; D'Amico, Anthony V.

    2005-01-01

    Purpose: We determined the acute gastrointestinal (GI), genitourinary (GU), and dermatologic (D) toxicity during dose-escalated three-dimensional conformal radiation therapy (3DCRT). A modified intrarectal balloon (Medrad) was used for prostate gland localization and immobilization. Methods: Forty-six men with clinical category T1c to T3a, and at least one high-risk feature (PSA >10, Gleason ≥7, or MRI evidence of extracapsular extension or seminal vesical invasion) comprised the study cohort. Treatment consisted of hormonal therapy and 4-field 3DCRT using an intrarectal balloon for the initial 15 of 40 treatments. Planning treatment volume dose was 72 Gy (95% normalization). A Mantel-Haenzel Chi-square test compared the distribution of GU, GI, and D symptoms at baseline and at end of treatment (EOT). Results: There was no significant difference between the 2 time points in the proportion of patients with bowel symptoms (p = 0.73), tenesmus (p = 0.27), nocturia (p = 1.00), or GU urgency (p = 0.40). However, there was a significant decrease in GU frequency (70% vs. 50%, p = 0.46) as a result of medical interventions and a significant increase in hemorrhoidal irritation (4% vs. 20%, p = 0.02) and anal cutaneous skin reaction (0% vs. 70%, p < 0.001). By 3 months after EOT compared to baseline, there was no significant difference in the proportion of patients experiencing hemorrhoidal bleeding (4% vs. 8%, p = 0.52), requiring intervention for hemorrhoidal symptoms (7% vs. 5%, p = 0.8), or experiencing persistent anal cutaneous skin reaction (0% vs. 3%, p = 0.31). Conclusion: Dose-escalated 3DCRT using an intrarectal balloon for prostate localization and immobilization was well tolerated. Acute GU, GI, and D symptoms resolved with standard dietary or medical interventions by the EOT or shortly thereafter

  17. Class solution to decrease rectal dose in prostate radiotherapy treatments 3D-CRT; Solucion de clase para disminuir dosis en recto en tratamientos de prostata con radioterapia 3D-CRT

    Energy Technology Data Exchange (ETDEWEB)

    Andres Rodriguez, C.; Tortosa Oliver, R.; Alonso Hernandez, D.; Mari Palacios, A.; Castillo Belmonte, A. del

    2011-07-01

    This paper contains a method developed in our center with conventional 3D radiotherapy techniques to increase the dose conformation around the target volume in prostate cancer treatments significantly reduced the doses to the rectum. To evaluate the goodness of the method, the results are compared with two classical techniques of treatment.

  18. Dosimetric comparison between CT and X-ray simulation of radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Kali Ayguli, Zhang Jinrong; Wang Juwu; Ge Feng; Wang Haifeng; Xu Suling

    2007-01-01

    Objective: To compare radiotherapy plan of conventional X-ray simulation with CT simulation by 3D-TPS for lung cancer. Methods: Thirty-three patients were allotted to receive both conventional X-ray simulation and CT simulation in the same treatment position. 3D-TPS was used to design 4-field conventional plan of X-ray simulation (RT), 4-field two dimensional plan(2D)and three dimensional conformal radiation plan(3DCRT) of CT simulation for all patients. The total dose was 50 Gy. Dose volume histogram(DVH) was applied to evaluate the difference of target coverage, dose distribution and normal tissue protection among the three plans. Results: 3DCRT and 2D based on CT simulation were superior to RT in the target coverage, target conformity index (TCI) and target homogeneity (TH) (P 20 , V 30 and mean lung dose were similar among 3DCRT, 2D and RT plans. Moreover, the maximum doses of spinal cord were significantly different among the three plans. No statistical differences of doses to 30% of the heart and esophagus volume among the three plans were observed. Conclusions: There is significantly better tumour volume coverage in CT simulation when compared with X-ray conventional simulation. Target volume delineation by CT simulation is improved significantly. The dose distribution is improved by using three dimensional treatment planning system. 3DCRT plan is superior to 2D plans in target conformity index and target homogeneity. Doses delivered to organs surrounding the target such as lung and heart were reduced significantly in 3DCRT. (authors)

  19. Physics aspects of recent and future concepts in radiotherapy

    International Nuclear Information System (INIS)

    Georg, D.

    2001-01-01

    Full text: The development of 3-D conformal radiotherapy (3D-CRT), in which the high dose volume matches as closely as possible the target volume and avoids therefore normal tissue irradiation as far as possible, has been a major theme in radiotherapy for improving the therapeutic window. Conformal radiotherapy is not a new concept but only the technological improvements of the last decade allow its clinical implementation. More recent and advanced forms of 3D-CRT are intensity modulated radiotherapy (IMRT) and stereotactic radiotherapy (SRT). IMRT uses an additional degree of freedom to achieve a new class of conformation: the variation of the primary beam intensity. SRT is based on a three dimensional stereotactic coordinate system which is correlated with the patient and the treatment facility through modern imaging technology. IMRT and SRT are related by common features, e.g. high dose gradients and small fields which require a high geometric precision. A high dosimetric and geometric precision can only be based on a detailed knowledge of the patient specific anatomy. Therefore, IMRT and SRT need to underlie multi-modality imaging studies. Both IMRT and SRT utilize photon beams and multiple field arrangements which increase the volumes of healthy tissue receiving low doses. Photons have a low selectivity along the beam direction implying that the sharp dose gradients are to be compromised. The increased low dose volume as well as the low selectivity of photon beams can be over-come by using proton or ions. Brachytherapy, a form of radiotherapy where encapsuled radioactive sources are placed directly in or in the vicinity of the tumor, is by definition conformal. Endovascular brachytherapy has become a promising new field in radiotherapy for the prevention of (re)stenosis after angioplasty. Although many clinical trials have been performed during the last years specific aspects related to endovascular brachytherapy have not been addressed clearly, such as the

  20. Radiotherapy of intensity modulated VS conformational in the treatment of carcinoma of the prostate. A dosimetric comparison; Radioterapia de intensidad modulada VS conformacional en el tratamiento de carcinoma de prostata. Una camparacion dosimetrica

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Martin, G.; Garcia Vicente, F.; Zapatero Laborda, A.; Bermudez Luna, R.; Roch Gonzalez, M.; Perez Gonzalez, L.; Torres Escobar, J. J.

    2013-07-01

    The intensity modulated (IMRT) radiation therapy is a technique of high conformation which, by its nature, has as one of its main directions prostate cancer radiotherapy treatment. The purpose of this work is presents results of the dosimetric indicators collected in our hospital a number of patients of carcinoma of the prostate with standard three-dimensional Conformal technique (3D-CRT) and IMRT. Aims to demonstrate and quantify with a statistical methodology that, establishing an adequate Protocol of IMRT, significant reductions in risk organ doses can be obtained by keeping the same prescription to the white volume. (Author)

  1. A Dosimetric Comparison of Accelerated Partial Breast Irradiation Techniques: Multicatheter Interstitial Brachytherapy, Three-Dimensional Conformal Radiotherapy, and Supine Versus Prone Helical Tomotherapy

    International Nuclear Information System (INIS)

    Patel, Rakesh R.; Becker, Stewart J.; Das, Rupak K.; Mackie, Thomas R.

    2007-01-01

    Purpose: To compare dosimetrically four different techniques of accelerated partial breast irradiation (APBI) in the same patient. Methods and Materials: Thirteen post-lumpectomy interstitial brachytherapy (IB) patients underwent imaging with preimplant computed tomography (CT) in the prone and supine position. These CT scans were then used to generate three-dimensional conformal radiotherapy (3D-CRT) and prone and supine helical tomotherapy (PT and ST, respectively) APBI plans and compared with the treated IB plans. Dose-volume histogram analysis and the mean dose (NTD mean ) values were compared. Results: Planning target volume coverage was excellent for all methods. Statistical significance was considered to be a p value mean dose of 1.3 Gy 3 and 1.2 Gy 3 , respectively. Both of these methods were statistically significantly lower than the supine external beam techniques. Overall, all four methods yielded similar low doses to the heart. Conclusions: The use of IB and PT resulted in greater normal tissue sparing (especially ipsilateral breast and lung) than the use of supine external beam techniques of 3D-CRT or ST. However, the choice of APBI technique must be tailored to the patient's anatomy, lumpectomy cavity location, and overall treatment goals

  2. Three-dimensional conformal external beam radiotherapy compared with permanent prostate implantation in low-risk prostate cancer based on endorectal magnetic resonance spectroscopy imaging and prostate-specific antigen level

    International Nuclear Information System (INIS)

    Pickett, Barby; Kurhanewicz, John; Pouliot, Jean; Weinberg, Vivian; Shinohara, Katsuto; Coakley, Fergus; Roach, Mack

    2006-01-01

    Purpose: To evaluate the metabolic response by comparing the time to resolution of spectroscopic abnormalities (TRSA) and the time to prostate-specific antigen level in low-risk prostate cancer patients after treatment with three-dimensional conformal external beam radiotherapy (3D-CRT) compared with permanent prostate implantation (PPI). Recent studies have suggested that the treatment of low-risk prostate cancer yields similar results for patients treated with 3D-CRT or PPI. Methods and Materials: A total of 50 patients, 25 in each group, who had been treated with 3D-CRT or PPI, had undergone endorectal magnetic resonance spectroscopy imaging before and/or at varying times after therapy. The 3D-CRT patients had received radiation doses of ≥72 Gy compared with 144 Gy for the PPI patients. The spectra from all usable voxels were examined for detectable levels of metabolic signal, and the percentages of atrophic and cancerous voxels were tabulated. Results: The median time to resolution of the spectroscopic abnormalities was 32.2 and 24.8 months and the time to the nadir prostate-specific antigen level was 52.4 and 38.0 months for the 3D-CRT and PPI patients, respectively. Of the 3D-CRT patients, 92% achieved negative endorectal magnetic resonance spectroscopy imaging findings, with 40% having complete metabolic atrophy. All 25 PPI patients had negative endorectal magnetic resonance spectroscopy imaging findings, with 60% achieving complete metabolic atrophy. Conclusion: The results of this study suggest that metabolic and biochemical responses of the prostate are more pronounced after PPI. Our results have not proved PPI is more effective at curing prostate cancer, but they have demonstrated that it may be more effective at destroying prostate metabolism

  3. Evaluation on prognosis of esophageal squamous cell carcinoma patients after three-dimensional conformal radiotherapy with different clinical stage system

    International Nuclear Information System (INIS)

    Wang Yuxiang; Zhu Shuchai; Qiu Rong; Liu Zhikun; Shen Wenbin

    2011-01-01

    Objective: To evaluate the prognostic significance of 3 clinical stage system in 3-dimensional conformal radiotherapy (3DCRT) for esophageal squamous cell carcinoma. Methods: From January 2004 to August 2007, 179 cases of esophageal squamous cell carcinoma were treated with 3DCRT. Before radiation, each patient was staged with UICC 2003 TNM stage, stage of Chinese esophageal cancer cooperation group (cooperation group' stage), and Zhu's clinical stage respectively. Concordance of each clinical stage and prognosis was analyzed with SPSS 11.5. Results In 179 cases of esophageal cancer, Concordance was better in T stage (Kappa = 0.271) than in TNM stage (Kappa = 0.167) between cooperation group' stage and Zhu's stage. Among them, 98 cases was staged with UICC stage, concordance of T stage was better between UICC-T and cooperation group' T stage (Kappa =0.261) than between UICCT and Zhu's T stage (Kappa = 0.045) ;concordance of TNM stage was better between UICC-TNM and Zhu's TNM stage (Kappa = 0.597) than between UICC-TNM and cooperation group' TNM stage (Kappa =0.299). With multivariate analysis, T (χ 2 value is 11.58, 26.00 and 51.05, all P 2 value is 15.28, 16.10 and 16.10, all P 2 value is 5.59, 27.78 and 27.78, all P 2 value is 15.77, 34, 35 and 51.10, all P 1 - T 3 was difficult to definite and the prognosis was not significantly different in T 1 - T 3 stage. Conclusions: In this study, 3 kinds of clinical stage could evaluate prognosis of esophageal cancer after radiotherapy; cooperation group' stage and Zhu's stage need further application, with further accuracy needed. (authors)

  4. A dosimetric comparison of 3D-CRT, IMRT, and static tomotherapy with an SIB for large and small breast volumes

    Energy Technology Data Exchange (ETDEWEB)

    Michalski, Andrea [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Central Coast Cancer Centre, Gosford Hospital, Gosford, New South Wales (Australia); Atyeo, John, E-mail: john.atyeo@sydney.edu.au [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Cox, Jennifer [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Department of Radiation Oncology, Royal North Shore Hospital, St Leonards, New South Wales (Australia); Rinks, Marianne [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Radiation Oncology, Cancer Services, Illawarra Shoalhaven Local Health District, Wollongong, New South Wales (Australia); Morgia, Marita; Lamoury, Gillian [Department of Radiation Oncology, Royal North Shore Hospital, St Leonards, New South Wales (Australia)

    2014-07-01

    Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. All patients were prescribed a dose of 45 Gy in 20 fractions to the breast with an SIB of 56 Gy in 20 fractions to the tumor bed and normalized so that D{sub 98%} > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D{sub 98%} > 95% and D{sub 2%} < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTV{sub boost} {sub eval} (0.079 ± 0.011) and breast minus the SIB volume (Breast{sub SIB}) (p < 0.001, 0.15 ± 0.03) compared with the PTV{sub boost} {sub eval} (0.085 ± 0.008, 0.088 ± 0.12) and Breast{sub SIB} (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11 Gy compared with 7.75 ± 2.54 Gy and 8.29 ± 2.76 Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26 Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44 Gy and 3.91 ± 1.58 Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D-CRT

  5. Sonographic Assessment of Parotid and Submandibular Glands in Patients Undergoing 3D Conformal Radiotherapy

    Directory of Open Access Journals (Sweden)

    Johari M

    2016-06-01

    Full Text Available The aim of this study was to evaluate sonographic changes in parotid and submandibular salivary glands in patients undergoing radiotherapy for head and neck malignancies. In addition, salivary changes subsequent to radiotherapy were evaluated objectively and subjectively. Twenty patients(13males and 7females with head and neck malignancies, who had been referred to the Radiotherapy/Oncology Department of the Shahid Madani Hospital in Tabriz, Iran, were included in the study. Length, width, echotexture, echogenicity and margins of parotid and submandibular glands were evaluated before and after radiotherapy using sonography. Peak-systolic velocity(PSV,end-diastolic velocity(EDV and resistive index(RI were also assessed by Doppler sonography. Xerostomia subsequent to radiotherapy was evaluated with the use of two techniques: patients’ self-reported scoring and objective measurement of resting saliva. There was a significant decrease in the width of the parotid gland after radiotherapy compared to baseline(P=0.005.Although the length of the parotid gland and the dimensions of submandibular gland decrease, the differences were not significant. In addition, the echogenicity, echotexture and the margin of the glands change to hypoechoic, heterogenic and irregular, respectively, subsequent to radiotherapy. The Doppler technique showed decrease in PSV and RI and an increase in EDV; however, only the decrease in RI in the submandibular gland was statistically significant(P=0.002.The results showed a significant decrease in salivary flow after radiotherapy(P<0.001.In addition, based on the patients reports, the severity of xerostomia increased significantly after radiotherapy(P<0.001. Songraphic changes of parotid and submandibular glands after radiotherapy should be considered in ultrasound examinations. The damages to the parotid and submandibular glands had significant influence in patient post 3D-CRT.

  6. Sucralfate versus mesalazine versus hydrocortisone in the prevention of acute radiation proctitis during conformal radiotherapy for prostate carcinoma. A randomized study

    International Nuclear Information System (INIS)

    Sanguineti, G.; Franzone, P.; Marcenaro, M.; Vitale, V.; Foppiano, F.

    2003-01-01

    Purpose: To assess whether the topical use of steroids or 5-aminosalicylic acid (5-ASA) is superior to sucralfate in preventing acute rectal toxicity during three-dimensional conformal radiotherapy (3DCRT) to 76 Gy. Patients and Methods: Patients undergoing 3DCRT for prostate carcinoma at our institution were offered to be randomized to sucralfate 3 g in 15 ml suspension enema (Antepsin trademark ), mesalazine 4 g gel enema (Enterasyn trademark), or hydrocortisone 100 mg foam enema (Colifoam trademark ). Randomization was blind to the treating physician but not to the patient. Sucralfate was chosen as control arm. Topical treatment had to be performed once daily, starting on day 1 of 3DCRT. Acute rectal toxicity was scored weekly according to RTOG criteria. Time to occurrence of grade 2+ acute rectal toxicity was taken as endpoint. Results: The trial was opened in August 1999, and after the first 24 patients had been treated, arm 2 was discontinued because of eight patients receiving mesalazine, seven actually developed acute rectal toxicity (five patients grade 3 and two patients grade 2). Until May 2001, 134 consecutive patients were randomly assigned to sucralfate (63 patients), mesalazine (eight patients) or hydrocortisone (63 patients). The cumulative incidence of acute rectal toxicity at the end of treatment by arm is 61.9 ± 6.1%, 87.5 ± 11.7%, and 52.4 ± 6.2% for arms 1, 2, and 3, respectively. The difference between the mesalazine group and the sucralfate group is highly significant (hazard ratio [HR] 2.5, 95% confidence interval [CI] 1.1-5.7; p = 0.03). At both uni- and multivariate analysis taking into account several patients and treatment covariates, the difference between hydrocortisone and sucralfate is not significant (HR 0.7, 95% CI 0.5-1.2; p = 0.2). Conclusion: Topical mesalazine is contraindicated during radiotherapy. Hydrocortisone enema is not superior to sucralfate in preventing acute rectal toxicity. (orig.)

  7. Sucralfate versus mesalazine versus hydrocortisone in the prevention of acute radiation proctitis during conformal radiotherapy for prostate carcinoma. A randomized study

    Energy Technology Data Exchange (ETDEWEB)

    Sanguineti, G.; Franzone, P.; Marcenaro, M.; Vitale, V. [Dept. of Radiation Oncology, National Inst. for Cancer Research, Genova (Italy); Foppiano, F. [Dept. of Physics, National Inst. for Cancer Research, Genova (Italy)

    2003-07-01

    Purpose: To assess whether the topical use of steroids or 5-aminosalicylic acid (5-ASA) is superior to sucralfate in preventing acute rectal toxicity during three-dimensional conformal radiotherapy (3DCRT) to 76 Gy. Patients and Methods: Patients undergoing 3DCRT for prostate carcinoma at our institution were offered to be randomized to sucralfate 3 g in 15 ml suspension enema (Antepsin {sup trademark}), mesalazine 4 g gel enema (Enterasyn trademark), or hydrocortisone 100 mg foam enema (Colifoam {sup trademark}). Randomization was blind to the treating physician but not to the patient. Sucralfate was chosen as control arm. Topical treatment had to be performed once daily, starting on day 1 of 3DCRT. Acute rectal toxicity was scored weekly according to RTOG criteria. Time to occurrence of grade 2+ acute rectal toxicity was taken as endpoint. Results: The trial was opened in August 1999, and after the first 24 patients had been treated, arm 2 was discontinued because of eight patients receiving mesalazine, seven actually developed acute rectal toxicity (five patients grade 3 and two patients grade 2). Until May 2001, 134 consecutive patients were randomly assigned to sucralfate (63 patients), mesalazine (eight patients) or hydrocortisone (63 patients). The cumulative incidence of acute rectal toxicity at the end of treatment by arm is 61.9 {+-} 6.1%, 87.5 {+-} 11.7%, and 52.4 {+-} 6.2% for arms 1, 2, and 3, respectively. The difference between the mesalazine group and the sucralfate group is highly significant (hazard ratio [HR] 2.5, 95% confidence interval [CI] 1.1-5.7; p = 0.03). At both uni- and multivariate analysis taking into account several patients and treatment covariates, the difference between hydrocortisone and sucralfate is not significant (HR 0.7, 95% CI 0.5-1.2; p = 0.2). Conclusion: Topical mesalazine is contraindicated during radiotherapy. Hydrocortisone enema is not superior to sucralfate in preventing acute rectal toxicity. (orig.)

  8. Conformal Radiotherapy: Physics, Treatment Planning and Verification. Proceedings book

    Energy Technology Data Exchange (ETDEWEB)

    De Wagter, C [ed.

    1995-12-01

    The goal of conformal radiotherapy is to establish radiation dose distributions that conform tightly to the target volume in view of limiting radiation to normal tissues. Conformal radiotherapy significantly improves both local control and palliation and thus contributes to increase survival and to improve the quality of life. The subjects covered by the symposium include : (1) conformal radiotherapy and multi-leaf collimation; (2) three dimensional imaging; (3) treatment simulation, planning and optimization; (4) quality assurance; and (5) dosimetry. The book of proceedings contains the abstracts of the invited lectures, papers and poster presentations as well as the full papers of these contributions.

  9. Conformal Radiotherapy: Physics, Treatment Planning and Verification. Proceedings book

    International Nuclear Information System (INIS)

    De Wagter, C.

    1995-12-01

    The goal of conformal radiotherapy is to establish radiation dose distributions that conform tightly to the target volume in view of limiting radiation to normal tissues. Conformal radiotherapy significantly improves both local control and palliation and thus contributes to increase survival and to improve the quality of life. The subjects covered by the symposium include : (1) conformal radiotherapy and multi-leaf collimation; (2) three dimensional imaging; (3) treatment simulation, planning and optimization; (4) quality assurance; and (5) dosimetry. The book of proceedings contains the abstracts of the invited lectures, papers and poster presentations as well as the full papers of these contributions

  10. Design and implementation of a rotational radiotherapy technique for breast cancer treatment and their comparison with 3-D-Crt irradiation technique; Diseno e implementacion de una tecnica de radioterapia rotacional para tratamiento de cancer de mama y su comparacion contra la tecnica 3D-CRT de irradiacion

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez M, J. G.; Lopez V, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Velazquez T, J. J.; Adame G, C. S. [Centro Medico Nacional Siglo XXI, Hospital de Oncologia, Departamento de Fisica Medica, Av. Cuauhtemoc No. 330, Col. Doctores, 06720 Mexico D. F. (Mexico); Rubio N, O.; Chagoya G, A.; Hernandez G, J. C., E-mail: jggm25@yahoo.com.mx [Centro Medico Nacional Siglo XXI, Hospital de Oncologia, Departamento de Radioterapia, Av. Cuauhtemoc No. 330, Col. Doctores, 06720 Mexico D. F. (Mexico)

    2015-10-15

    Breast cancer is one of oncological diseases worldwide, as well in Mexico, which causes even more deaths than cervical cancer; this condition is the second death cause in women aged 30-54 years and threatens all socio-economic groups. The treatment is highly dependent on the stage which is detected and based on protocols that include a combination of surgery, chemotherapy and radiotherapy. This paper studies the main irradiation technique for patients with mastectomy, breast full cycle (irradiation of the chest well and supraclavicular nodes) in their mode Three Dimensional - Conformal Radiation Therapy (3-D-Crt), and compared with the Volumetric Modulated Arc Therapy (VMAT) technique proposed in this paper. In both techniques the prescription was 50 Gy divided into 25 fractions. The techniques were applied in three female patients (being an initial study) with disease of the left side, the target volume and organs at risk were delineated by the medical treating radiation oncologist, the planning system used was Eclipse version 10; for quantitative comparison of both plans indexes of homogeneity were used, con formality, the target volume coverage and normal tissue, sub factors and overdosing, the conformation number and coverage quality. They were evaluated and compared the media, maximum and minimum dose of the organs at risk, based on the fact that the coverage of the target volume, dose gradient and dose at risk organs are acceptable (prescription dose greater that 90% coverage, gradient less that 20% and organs at risk in accordance with the Quantec limitations for both versions). (Author)

  11. Dosimetric Study of Current Treatment Options for Radiotherapy in Retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Eldebawy, Eman [Department of Radiation Oncology, McGill University Health Centre, Montreal, Quebec (Canada); Department of Radiation Oncology, Children' s Cancer Hospital, Cairo (Egypt); Parker, William, E-mail: william.parker@mcgill.ca [Department of Medical Physics, McGill University Health Centre, Montreal, Quebec (Canada); Abdel Rahman, Wamied [Department of Medical Physics, McGill University Health Centre, Montreal, Quebec (Canada); Freeman, Carolyn R. [Department of Radiation Oncology, McGill University Health Centre, Montreal, Quebec (Canada)

    2012-03-01

    Purpose: To determine the best treatment technique for patients with retinoblastoma requiring radiotherapy to the whole eye. Methods and Materials: Treatment plans for 3 patients with retinoblastoma were developed using 10 radiotherapy techniques including electron beams, photon beam wedge pair (WP), photon beam three-dimensional conformal radiotherapy (3D-CRT), fixed gantry intensity-modulated radiotherapy (IMRT), photon volumetric arc therapy (VMAT), fractionated stereotactic radiotherapy, and helical tomotherapy (HT). Dose-volume analyses were carried out for each technique. Results: All techniques provided similar target coverage; conformity was highest for VMAT, nine-field (9F) IMRT, and HT (conformity index [CI] = 1.3) and lowest for the WP and two electron techniques (CI = 1.8). The electron techniques had the highest planning target volume dose gradient (131% of maximum dose received [D{sub max}]), and the CRT techniques had the lowest (103% D{sub max}) gradient. The volume receiving at least 20 Gy (V{sub 20Gy}) for the ipsilateral bony orbit was lowest for the VMAT and HT techniques (56%) and highest for the CRT techniques (90%). Generally, the electron beam techniques were superior in terms of brain sparing and delivered approximately one-third of the integral dose of the photon techniques. Conclusions: Inverse planned image-guided radiotherapy delivered using HT or VMAT gives better conformity index, improved orbital bone and brain sparing, and a lower integral dose than other techniques.

  12. Decreasing Temporal Lobe Dose With Five-Field Intensity-Modulated Radiotherapy for Treatment of Pituitary Macroadenomas

    International Nuclear Information System (INIS)

    Parhar, Preeti K.; Duckworth, Tamara; Shah, Parinda; DeWyngaert, J. Keith; Narayana, Ashwatha; Formenti, Silvia C.; Shah, Jinesh N.

    2010-01-01

    Purpose: To compare temporal lobe dose delivered by three pituitary macroadenoma irradiation techniques: three-field three-dimensional conformal radiotherapy (3D-CRT), three-field intensity-modulated radiotherapy (3F IMRT), and a proposed novel alternative of five-field IMRT (5F IMRT). Methods and Materials: Computed tomography-based external beam radiotherapy planning was performed for 15 pituitary macroadenoma patients treated at New York University between 2002 and 2007 using: 3D-CRT (two lateral, one midline superior anterior oblique [SAO] beams), 3F IMRT (same beam angles), and 5F IMRT (same beam angles with additional right SAO and left SAO beams). Prescription dose was 45 Gy. Target volumes were: gross tumor volume (GTV) = macroadenoma, clinical target volume (CTV) = GTV, and planning target volume = CTV + 0.5 cm. Structure contouring was performed by two radiation oncologists guided by an expert neuroradiologist. Results: Five-field IMRT yielded significantly decreased temporal lobe dose delivery compared with 3D-CRT and 3F IMRT. Temporal lobe sparing with 5F IMRT was most pronounced at intermediate doses: mean V25Gy (% of total temporal lobe volume receiving ≥25 Gy) of 13% vs. 28% vs. 29% for right temporal lobe and 14% vs. 29% vs. 30% for left temporal lobe for 5F IMRT, 3D-CRT, and 3F IMRT, respectively (p -7 for 5F IMRT vs. 3D-CRT and 5F IMRT vs. 3F IMRT). Five-field IMRT plans did not compromise target coverage, exceed normal tissue dose constraints, or increase estimated brain integral dose. Conclusions: Five-field IMRT irradiation technique results in a statistically significant decrease in the dose to the temporal lobes and may thus help prevent neurocognitive sequelae in irradiated pituitary macroadenoma patients.

  13. Significant reduction of normal tissue dose by proton radiotherapy compared with three-dimensional conformal or intensity-modulated radiation therapy in Stage I or Stage III non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Chang, Joe Y.; Zhang Xiaodong; Wang Xiaochun; Kang Yixiu; Riley, Beverly C.; Bilton, Stephen C.; Mohan, Radhe; Komaki, Ritsuko; Cox, James D.

    2006-01-01

    Purpose: To compare dose-volume histograms (DVH) in patients with non-small-cell lung cancer (NSCLC) treated by photon or proton radiotherapy. Methods and Materials: Dose-volume histograms were compared between photon, including three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and proton plans at doses of 66 Gy, 87.5 Gy in Stage I (n = 10) and 60-63 Gy, and 74 Gy in Stage III (n 15). Results: For Stage I, the mean total lung V5, V10, and V20 were 31.8%, 24.6%, and 15.8%, respectively, for photon 3D-CRT with 66 Gy, whereas they were 13.4%, 12.3%, and 10.9%, respectively, with proton with dose escalation to 87.5 cobalt Gray equivalents (CGE) (p = 0.002). For Stage III, the mean total lung V5, V10, and V20 were 54.1%, 46.9%, and 34.8%, respectively, for photon 3D-CRT with 63 Gy, whereas they were 39.7%, 36.6%, and 31.6%, respectively, for proton with dose escalation to 74 CGE (p = 0.002). In all cases, the doses to lung, spinal cord, heart, esophagus, and integral dose were lower with proton therapy even compared with IMRT. Conclusions: Proton treatment appears to reduce dose to normal tissues significantly, even with dose escalation, compared with standard-dose photon therapy, either 3D-CRT or IMRT

  14. Radiation-induced esophagitis in local advanced non-small cell lung cancer after three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Tian Dandan; Wang Yuxiang; Qiu Rong; Zhu Shuchai; Tian Xiuming; Qiao Xueying

    2014-01-01

    Objective: To explore radiation-induced esophagitis and its related factors in the patients with local advanced non-small cell lung cancer (NSCLC) which were treated with three-dimensional conformal radiation therapy (3D-CRT). Methods: From January 2001 to December 2008, 203 patients who suffered from stage Ⅲ NSCLC were achieved, including 163 males and 40 females, with a median age of 63 years old, while 79 cases were in stage Ⅲ_a and 124 in stage Ⅲ_b. The equivalent median dose of tumor was 62 Gy(range of 50-78 Gy). Among them, 74 cases were administered with radiotherapy alone, 45 with sequential radiotherapy and chemotherapy, 87 cases with concurrent radiochemotherapy. Radiation esophagitis was evaluated with RTOG standard. The dosimetric parameters was estimated from dose volume histogrma (DVH). The clinical and dosimetric parameters of radiation esophagitis were evaluated by spearman correlatived univariate and Logistic multivariable analysis.Results After radiotherapy, out of 203 patients, 87 had acute radiation esophagitis(RE), 47 in grade 1, 37 in grade 2, and 3 in grade 3 RE. According to spearman correlatived analysis, the correlatived factors included ages, chemotherapy, GTV, PTV, the mean doses of PTV and lung, the max and mean dose of esophagus, V_4_0, V_4_5, V_5_0, V_5_5, V_6_0, length of esophagus (total circumference) treated with 45 Gy (LETT_4_5), and LETT_5_0 (r = -0.162-0.235, P 0.05). There were 21 factors, such as gender, age, smoking, clinical stage, site of tumor, chemotherapy, GTV, PTV, mean dose of PTV and lung, max and mean dose of esophagus, V_4_0-V_6_0 of esophagus, LETT_4_5_-_6_0, incorporated into multivariable analysis, only chemotherapy and V_4_5 of esophagus were independent predicted factors(Wald = 4.626, 9.882, P < 0.05). Conclusions: In local advanced NSCLC after 3D-CRT, chemotherapy(especially concurrent radiochemotherapy) could increase radiation-induced esophagitis. The parameter of DVH could also be used to predict

  15. Comparison of rectal volume definition techniques and their influence on rectal toxicity in patients with prostate cancer treated with 3D conformal radiotherapy: a dose-volume analysis

    International Nuclear Information System (INIS)

    Onal, Cem; Topkan, Erkan; Efe, Esma; Yavuz, Melek; Sonmez, Serhat; Yavuz, Aydin

    2009-01-01

    To evaluate the impact of four different rectum contouring techniques and rectal toxicities in patients with treated with 3D conformal radiotherapy (3DCRT). Clinical and dosimetric data were evaluated for 94 patients who received a total dose 3DCRT of 70 Gy, and rectal doses were compared in four different rectal contouring techniques: the prostate-containing CT sections (method 1); 1 cm above and below the planning target volume (PTV) (method 2); 110 mm starting from the anal verge (method 3); and from the anal verge to the sigmoid flexure (method 4). The percentage of rectal volume receiving RT doses (30–70 Gy) and minimum, mean rectal doses were assessed. Median age was 69 years. Percentage of rectal volume receiving high doses (≥ 70 Gy) were higher with the techniques that contoured smaller rectal volumes. In methods 2 and 3, the percentage of rectal volume receiving ≥ 70 Gy was significantly higher in patients with than without rectal bleeding (method 2: 30.8% vs. 22.5%, respectively (p = 0.03); method 3: 26.9% vs. 18.1%, respectively (p = 0.006)). Mean rectal dose was significant predictor of rectal bleeding only in method 3 (48.8 Gy in patients with bleeding vs. 44.4 Gy in patients without bleeding; p = 0.02). Different techniques of rectal contouring significantly influence the calculation of radiation doses to the rectum and the prediction of rectal toxicity. Rectal volume receiving higher doses (≥ 70 Gy) and mean rectal doses may significantly predict rectal bleeding for techniques contouring larger rectal volumes, as was in method 3

  16. Pulmonary Toxicity in Stage III Non-Small Cell Lung Cancer Patients Treated With High-Dose (74 Gy) 3-Dimensional Conformal Thoracic Radiotherapy and Concurrent Chemotherapy Following Induction Chemotherapy: A Secondary Analysis of Cancer and Leukemia Group B (CALGB) Trial 30105

    International Nuclear Information System (INIS)

    Salama, Joseph K.; Stinchcombe, Thomas E.; Gu Lin; Wang Xiaofei; Morano, Karen; Bogart, Jeffrey A.; Crawford, Jeffrey C.; Socinski, Mark A.; Blackstock, A. William; Vokes, Everett E.

    2011-01-01

    Purpose: Cancer and Leukemia Group B (CALGB) 30105 tested two different concurrent chemoradiotherapy platforms with high-dose (74 Gy) three-dimensional conformal radiotherapy (3D-CRT) after two cycles of induction chemotherapy for Stage IIIA/IIIB non–small cell lung cancer (NSCLC) patients to determine if either could achieve a primary endpoint of >18-month median survival. Final results of 30105 demonstrated that induction carboplatin and gemcitabine and concurrent gemcitabine 3D-CRT was not feasible because of treatment-related toxicity. However, induction and concurrent carboplatin/paclitaxel with 74 Gy 3D-CRT had a median survival of 24 months, and is the basis for the experimental arm in CALGB 30610/RTOG 0617/N0628. We conducted a secondary analysis of all patients to determine predictors of treatment-related pulmonary toxicity. Methods and Materials: Patient, tumor, and treatment-related variables were analyzed to determine their relation with treatment-related pulmonary toxicity. Results: Older age, higher N stage, larger planning target volume (PTV)1, smaller total lung volume/PTV1 ratio, larger V20, and larger mean lung dose were associated with increasing pulmonary toxicity on univariate analysis. Multivariate analysis confirmed that V20 and nodal stage as well as treatment with concurrent gemcitabine were associated with treatment-related toxicity. A high-risk group comprising patients with N3 disease and V20 >38% was associated with 80% of Grades 3-5 pulmonary toxicity cases. Conclusions: Elevated V20 and N3 disease status are important predictors of treatment related pulmonary toxicity in patients treated with high-dose 3D-CRT and concurrent chemotherapy. Further studies may use these metrics in considering patients for these treatments.

  17. Pulmonary Toxicity in Stage III Non-Small Cell Lung Cancer Patients Treated With High-Dose (74 Gy) 3-Dimensional Conformal Thoracic Radiotherapy and Concurrent Chemotherapy Following Induction Chemotherapy: A Secondary Analysis of Cancer and Leukemia Group B (CALGB) Trial 30105

    Energy Technology Data Exchange (ETDEWEB)

    Salama, Joseph K., E-mail: joseph.salama@duke.edu [Duke University Medical Center, Durham, NC (United States); Stinchcombe, Thomas E. [University of North Carolina at Chapel Hill, Chapel Hill, NC (United States); Gu Lin; Wang Xiaofei [CALGB Statistical Center, Duke University Medical Center, Durham, NC (United States); Morano, Karen [Quality Assurance Review Center, Lincoln, RI (United States); Bogart, Jeffrey A. [State University of New York Upstate Medical University, Syracuse, NY (United States); Crawford, Jeffrey C. [Duke University Medical Center, Durham, NC (United States); Socinski, Mark A. [University of North Carolina at Chapel Hill, Chapel Hill, NC (United States); Blackstock, A. William [Wake Forest University School of Medicine, Winston-Salem, NC (United States); Vokes, Everett E. [University of Chicago, Chicago, IL (United States)

    2011-11-15

    Purpose: Cancer and Leukemia Group B (CALGB) 30105 tested two different concurrent chemoradiotherapy platforms with high-dose (74 Gy) three-dimensional conformal radiotherapy (3D-CRT) after two cycles of induction chemotherapy for Stage IIIA/IIIB non-small cell lung cancer (NSCLC) patients to determine if either could achieve a primary endpoint of >18-month median survival. Final results of 30105 demonstrated that induction carboplatin and gemcitabine and concurrent gemcitabine 3D-CRT was not feasible because of treatment-related toxicity. However, induction and concurrent carboplatin/paclitaxel with 74 Gy 3D-CRT had a median survival of 24 months, and is the basis for the experimental arm in CALGB 30610/RTOG 0617/N0628. We conducted a secondary analysis of all patients to determine predictors of treatment-related pulmonary toxicity. Methods and Materials: Patient, tumor, and treatment-related variables were analyzed to determine their relation with treatment-related pulmonary toxicity. Results: Older age, higher N stage, larger planning target volume (PTV)1, smaller total lung volume/PTV1 ratio, larger V20, and larger mean lung dose were associated with increasing pulmonary toxicity on univariate analysis. Multivariate analysis confirmed that V20 and nodal stage as well as treatment with concurrent gemcitabine were associated with treatment-related toxicity. A high-risk group comprising patients with N3 disease and V20 >38% was associated with 80% of Grades 3-5 pulmonary toxicity cases. Conclusions: Elevated V20 and N3 disease status are important predictors of treatment related pulmonary toxicity in patients treated with high-dose 3D-CRT and concurrent chemotherapy. Further studies may use these metrics in considering patients for these treatments.

  18. A high-precision system for conformal intracranial radiotherapy

    International Nuclear Information System (INIS)

    Tome, Wolfgang A.; Meeks, Sanford L.; Buatti, John M.; Bova, Francis J.; Friedman, William A.; Li Zuofeng

    2000-01-01

    Purpose: Currently, optimally precise delivery of intracranial radiotherapy is possible with stereotactic radiosurgery and fractionated stereotactic radiotherapy. We report on an optimally precise optically guided system for three-dimensional (3D) conformal radiotherapy using multiple noncoplanar fixed fields. Methods and Materials: The optically guided system detects infrared light emitting diodes (IRLEDs) attached to a custom bite plate linked to the patient's maxillary dentition. The IRLEDs are monitored by a commercially available stereo camera system, which is interfaced to a personal computer. An IRLED reference is established with the patient at the selected stereotactic isocenter, and the computer reports the patient's current position based on the location of the IRLEDs relative to this reference position. Using this readout from the computer, the patient may be dialed directly to the desired position in stereotactic space. The patient is localized on the first day and a reference file is established for 5 different couch positions. The patient's image data are then imported into a commercial convolution-based 3D radiotherapy planning system. The previously established isocenter and couch positions are then used as a template upon which to design a conformal 3D plan with maximum beam separation. Results: The use of the optically guided system in conjunction with noncoplanar radiotherapy treatment planning using fixed fields allows the generation of highly conformal treatment plans that exhibit a high degree of dose homogeneity and a steep dose gradient. To date, this approach has been used to treat 28 patients. Conclusion: Because IRLED technology improves the accuracy of patient localization relative to the linac isocenter and allows real-time monitoring of patient position, one can choose treatment-field margins that only account for beam penumbra and image resolution without adding margin to account for larger and poorly defined setup uncertainty. This

  19. Results of a multicentric in silico clinical trial (ROCOCO): comparing radiotherapy with photons and protons for non-small cell lung cancer.

    Science.gov (United States)

    Roelofs, Erik; Engelsman, Martijn; Rasch, Coen; Persoon, Lucas; Qamhiyeh, Sima; de Ruysscher, Dirk; Verhaegen, Frank; Pijls-Johannesma, Madelon; Lambin, Philippe

    2012-01-01

    This multicentric in silico trial compares photon and proton radiotherapy for non-small cell lung cancer patients. The hypothesis is that proton radiotherapy decreases the dose and the volume of irradiated normal tissues even when escalating to the maximum tolerable dose of one or more of the organs at risk (OAR). Twenty-five patients, stage IA-IIIB, were prospectively included. On 4D F18-labeled fluorodeoxyglucose-positron emission tomography-computed tomography scans, the gross tumor, clinical and planning target volumes, and OAR were delineated. Three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) photon and passive scattered conformal proton therapy (PSPT) plans were created to give 70 Gy to the tumor in 35 fractions. Dose (de-)escalation was performed by rescaling to the maximum tolerable dose. Protons resulted in the lowest dose to the OAR, while keeping the dose to the target at 70 Gy. The integral dose (ID) was higher for 3DCRT (59%) and IMRT (43%) than for PSPT. The mean lung dose reduced from 18.9 Gy for 3DCRT and 16.4 Gy for IMRT to 13.5 Gy for PSPT. For 10 patients, escalation to 87 Gy was possible for all 3 modalities. The mean lung dose and ID were 40 and 65% higher for photons than for protons, respectively. The treatment planning results of the Radiation Oncology Collaborative Comparison trial show a reduction of ID and the dose to the OAR when treating with protons instead of photons, even with dose escalation. This shows that PSPT is able to give a high tumor dose, while keeping the OAR dose lower than with the photon modalities.

  20. Intensity-Modulated Radiotherapy Reduces Gastrointestinal Toxicity in Patients Treated With Androgen Deprivation Therapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Sharma, Navesh K.; Li Tianyu; Chen, David Y.; Pollack, Alan; Horwitz, Eric M.; Buyyounouski, Mark K.

    2011-01-01

    Purpose: Androgen deprivation therapy (AD) has been shown to increase late Grade 2 or greater rectal toxicity when used concurrently with three-dimensional conformal radiotherapy (3D-CRT). Intensity-modulated radiotherapy (IMRT) has the potential to reduce toxicity by limiting the radiation dose received by the bowel and bladder. The present study compared the genitourinary and gastrointestinal (GI) toxicity in men treated with 3D-CRT+AD vs. IMRT+AD. Methods and Materials: Between July 1992 and July 2004, 293 men underwent 3D-CRT (n = 170) or IMRT (n = 123) with concurrent AD (<6 months, n = 123; ≥6 months, n = 170). The median radiation dose was 76 Gy for 3D-CRT (International Commission on Radiation Units and Measurements) and 76 Gy for IMRT (95% to the planning target volume). Toxicity was assessed by a patient symptom questionnaire that was completed at each visit and recorded using a Fox Chase Modified Late Effects Normal Tissue Task radiation morbidity scale. Results: The mean follow-up was 86 months (standard deviation, 29.3) for the 3D-CRT group and 40 months (standard deviation, 9.7) for the IMRT group. Acute GI toxicity (odds ratio, 4; 95% confidence interval, 1.6-11.7; p = .005) was significantly greater with 3D-CRT than with IMRT and was independent of the AD duration (i.e., <6 vs. ≥6 months). The interval to the development of late GI toxicity was significantly longer in the IMRT group. The 5-year Kaplan-Meier estimate for Grade 2 or greater GI toxicity was 20% for 3D-CRT and 8% for IMRT (p = .01). On multivariate analysis, Grade 2 or greater late GI toxicity (hazard ratio, 2.1; 95% confidence interval, 1.1-4.3; p = .04) was more prevalent in the 3D-CRT patients. Conclusion: Compared with 3D-CRT, IMRT significantly decreased the acute and late GI toxicity in patients treated with AD.

  1. Three-dimensional conformal radiotherapy by delineations on CT-based simulation in different respiratory phases for the treatment of senile patients with non-small cell lung cancer.

    Science.gov (United States)

    Wang, Weifeng; Yuan, Feng; Wang, Guoping; Lin, Zhiren; Pan, Yanling; Chen, Longhua

    2015-01-01

    This study aimed to evaluate the application of three-dimensional conformal radiotherapy (3D-CRT) for elderly patients with non-small cell lung cancer (NSCLC) based on computed tomography (CT) simulations in different respiratory phases. A total of 64 patients aged >70 years old with NSCLC were treated by 3D-CRT using CT images in different respiratory phases. The gross tumor volumes (GTVs) at the end of inspiration and end of expiration were combined to obtain the total GTV, which was close to the motional range of tumors during respiration, and no additional expansion of the clinical target volume (CTAV) to planning target volume (PTV) (CTAV:PTV) was included during the recording of respiratory movements. Patients were also planned according to the classic 3D-CRT approach. Efficacy, prognostic factors, and side effects were evaluated. Compared with the classic approach, the average PTV was 18.9% lower (median: 17.3%), and the average lung volume receiving a prescribed dose for a tumor was 22.4% lower (median: 20.9%). The 1-, 2-, and 3-year survival rates were 70.6%, 54.9%, and 29.4%, respectively, with an overall tumor response rate of 79.7%. The Karnofsky performance status and N stage were independent prognostic factors, whereas age was not. Without affecting therapeutic effects, CT simulations in different respiratory phases were well-tolerated in elderly patients with NSCLC, could effectively reduce PTV, and could improve the quality of life.

  2. Prediction of PET/CT to alleviate radiation pneumonitis in patients with non-small cell lung cancer for 3-dimentional conformal radiotherapy

    International Nuclear Information System (INIS)

    Gong Heyi; Yu Jinming; Li Jianbin; Li Baosheng; Fu Zheng; Liu Tonghai

    2005-01-01

    Objective: To investigate the impact of PET/CT on clinical staging of non-small cell lung cancer (NSCLC), delineation of target volume, and prediction to alleviate radiation pneumonitis (RP) from 3-dimentional conformal radiotherapy (3D-CRT) planning. Methods: From October 2002 to June 2004, 34 patients diagnosed cytologically or pathologically with NSCLC, who were candidates for radical radiotherapy or surgery, received PET/CT scanning. Both images were transmitted into treatment planning system (TPS) workstations respectively and were fused and reconstructed. All patients were staged according to the 1997 World Health Organization (WHO) staging system. The impact of PET/CT on the clinical staging of all the patients was determined. The gross tumor volume (GTV) was delineated on the CT imaging and PET/CTfused imaging respectively. Based on the two images, 3D- CRT planning was made respectively at the TPS workstation with Topslane software, the planning target volumes (PTV) being defined with a 15 mm margin around GTV of primary lumps (PTV 1 ) and 7 mm for involved lymph nodes (PTV 2 ). Evaluating indexes including V PTV (volume of PTV, V PTV = V PTV1 + V PTV2 ), V 20 (percentage of the total lung volume receiving more than 20 Gy), MLD (mean lung dose) , TCP (tumor control probability) , NTCP (normal tissue complication probability) , and Ds (dose to spinal cord) were selected to be paralleled to compare the quality of the two plans and the impact of PET/CT on RP was further analyzed. Results: In 13 of 34 (38.2%) cases, PET/CT information changed the clinical staging, 8 of which were upstaged and 5 downstaged. For 10 of 34 (29.4%) cases, PET/CT results modified their management decisions. Among 16 patients performed by surgery, 14 had consistent PET/CT staging with pathologic staging. The sensitivity of PET/CT was 93.3% and accuracy 87.5%. Difference of indexes including V PTV , V 20 and MLD between the two radiation planning was statistically significant, but Ds

  3. Gel dosimetry for conformal radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G [Department of Physics of the University and INFN, Milan (Italy)

    2005-07-01

    With the continuum development of conformal radio therapies, aimed at delivering high dose to tumor tissue and low dose to the healthy tissue around, the necessities has appeared of suitable improvement of dosimetry techniques giving the possibility of obtaining dose images to be compared with diagnostic images. Also if wide software has been developed for calculating dose distributions in the fields of various radiotherapy units, experimental verifications are necessary, in particular in the case of complex geometries in conformal radiotherapy. Gel dosimetry is a promising method for imaging the absorbed dose in tissue-equivalent phantoms, with the possibility of 3D reconstruction of the spatial dose distribution, with milli metric resolution. Optical imaging of gel dosimeters, based on visible light absorbance analysis, has shown to be a reliable technique for achieving dose distributions. (Author)

  4. Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: A dosimetric and treatment efficiency analysis

    International Nuclear Information System (INIS)

    McGrath, Samuel D.; Matuszak, Martha M.; Yan Di; Kestin, Larry L.; Martinez, Alvaro A.; Grills, Inga S.

    2010-01-01

    Purpose/objective(s): Volumetric modulated arc therapy (VMAT) allows for intensity-modulated radiation delivery during gantry rotation with dynamic MLC motion, variable dose rates and gantry speed modulation. We compared VMAT plans with 3D-CRT for hypofractionated lung radiotherapy. Materials/methods: Twenty-one 3D-CRT plans for Stage IA lung cancer previously treated stereotactically were selected. VMAT plans were generated by optimizing machine aperture shape and radiation intensity at 10 deg. intervals. A partial arc range of 180 deg. was manually selected to coincide with tumor location. The arc was resampled down to 5 deg. intervals to ensure dose calculation accuracy. Identical planning objectives were used for VMAT/3D-CRT. Parameters assessed included dose to PTV and organs-at-risk (OAR), monitor units, and multiple conformity and homogeneity indices. Plans were delivered to a phantom for time comparison. Results: Lung V 20/12.5/10/5 were less with VMAT (relative reduction 4.5%, p = .02; 3.2%, p = .01; 2.6%, p = .01; 4.2%, p = .03, respectively). Mean/maximum-doses to PTV, dose to additional OARs, 95% isodose line conformity, and target volume homogeneity were equivalent. VMAT improved conformity at both the 80% (1.87 vs. 1.93, p = .08) and 50% isodose lines (5.19 vs. 5.65, p = .01). Treatment times were reduced significantly with VMAT (mean 6.1 vs. 11.9 min, p < .01). Conclusions: Single arc VMAT planning achieves highly conformal dose distributions while controlling dose to critical structures, including significant reduction in lung dose volume parameters. Employing a VMAT technique decreases treatment times by 37-63%, reducing the chance of error introduced by intrafraction variation. The quality and efficiency of VMAT is ideally suited for stereotactic lung radiotherapy delivery.

  5. Treatment results of radiotherapy for medically inoperable stage I/II non-small cell lung cancer

    International Nuclear Information System (INIS)

    Zhang Li; Wang Lvhua; Zhang Hongxing; Chen Dongfu; Xiao Zefen; Wang Mei; Feng Qinfu; Liang Jun; Zhou Zongmei; Ou Guangfei; Lv Jima; Yin Weibo

    2008-01-01

    Objective: To retrospectively analyze treatment results of radiotherapy for medically inoperable stage I/II non-small cell lung cancer. Methods: Between Jan. 2000 and Dec. 2005, fifty-eight such patients were enrolled into the database analysis, including 37 with clinical stage I and 21 with stage II disease. Fifty patients received radiotherapy alone and eight with radiotherapy and chemotherapy. Forty- three patients were treated with 3-D conformal radiotherapy (3D-CRT) and 15 with conventional radiotherapy. Results: The 1-, 2- and 3-year overall survival rates were 85%, 54% and 30%, and the median survival time was 26.2 months for the whole group. The corresponding figures were 88%, 60%, 36% and 30.8 months for cancer-specific survival; 84%, 64%, 31% and 30.8 months for Stage I disease; 81%, 47%, 28% and 18.8 months for Stage II disease; 95%, 57%, 33% and 30.8 months for 3D-CRT group and 53%, 44%, 24% and 15.3 months for conventional radiotherapy group. By logrank test, tumor volume, pneumonitis of Grade II or higher and weight loss more than 5% showed statistically significant impact on overall survival. Tumor volume was the only independent prognostic factor in Cox multivariable regression. Pneumonitis and esophagitis of Grade II or higher were 16% and 2%, respectively. Age and lung function before treatment had a significant relationship with pneumonitis. Failure included the local recurrence (33%) and distant metastasis (21%). There was no difference between the treatment modalities and failure sites. Conclusions: For medically inoperable early stage non-small cell lung cancer patients, tumor volume is the most important prognostic factor for overall survival. The conformal radiotherapy marginally improves the survival. The age and pulmonary function are related to the incidence of treatment induced pneumonitis. (authors)

  6. Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit

    OpenAIRE

    Rutonjski Laza; Petrović Borislava; Baucal Milutin; Teodorović Milan; Čudić Ozren; Gershkevitsh Eduard; Izewska Joanna

    2012-01-01

    Abstract Background Independent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT) workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes. Methods The audit was conducte...

  7. Time management in radiation oncology: evaluation of time, attendance of medical staff, and resources during radiotherapy for prostate cancer: the DEGRO-QUIRO trial.

    Science.gov (United States)

    Keilholz, L; Willner, J; Thiel, H-J; Zamboglou, N; Sack, H; Popp, W

    2014-01-01

    In order to evaluate resource requirements, the German Society of Radiation Oncology (DEGRO) recorded the times needed for core procedures in the radio-oncological treatment of various cancer types within the scope of its QUIRO trial. The present study investigated the personnel and infrastructural resources required in radiotherapy of prostate cancer. The investigation was carried out in the setting of definitive radiotherapy of prostate cancer patients between July and October 2008 at two radiotherapy centers, both with well-trained staff and modern technical facilities at their disposal. Personnel attendance times and room occupancy times required for core procedures (modules) were each measured prospectively by two independently trained observers using time measurements differentiated on the basis of professional group (physician, physicist, and technician), 3D conformal (3D-cRT), and intensity-modulated radiotherapy (IMRT). Total time requirements of 983 min for 3D-cRT and 1485 min for step-and-shoot IMRT were measured for the technician (in terms of professional group) in all modules recorded and over the entire course of radiotherapy for prostate cancer (72-76 Gy). Times needed for the medical specialist/physician were 255 min (3D-cRT) and 271 min (IMRT), times of the physicist were 181 min (3D-cRT) and 213 min (IMRT). The difference in time was significant, although variations in time spans occurred primarily as a result of various problems during patient treatment. This investigation has permitted, for the first time, a realistic estimation of average personnel and infrastructural requirements for core procedures in quality-assured definitive radiotherapy of prostate cancer. The increased time needed for IMRT applies to the step-and-shoot procedure with verification measurements for each irradiation planning.

  8. Interobserver delineation uncertainty in involved-node radiation therapy (INRT) for early-stage Hodgkin lymphoma: on behalf of the Radiotherapy Committee of the EORTC lymphoma group

    DEFF Research Database (Denmark)

    Aznar, Marianne C.; Girinsky, Theodore; Berthelsen, Anne Kiil

    2017-01-01

    deviations between the surfaces of the observer and consensus contour (Hausdorff distance). 3D-conformal (3D-CRT) and intensity-modulated radiotherapy (IMRT) plans were calculated for each contour in order to investigate the impact of interobserver variability on each treatment modality. Similar target...... of the systematic error associated with delineation uncertainty, ranged from 1.9 to 3.8 mm (median: 3.2 mm). Variations in mean dose resulting from different observer contours were small and were not higher in IMRT plans than in 3D-CRT plans. CONCLUSIONS: We observed considerable differences in target volume...

  9. Dosimetry study on the conventional and three dimensional conformal radiation treatment planning protocols for rectal cancer

    International Nuclear Information System (INIS)

    Cai Yong; He Yuxiang; Han Shukui; Wu Hao; Gong Jian; Xu Bo

    2007-01-01

    Objective: To compare the dose distribution of clinical target volume (CTV), in normal tissues and organs for patients with rectal cancer on the conventional radiotherapy (2D) and three dimension- al conformal radiation treatment (3DCRT). Methods: The CT image data of 36 rectal cancer patients treated with 3DCRT were studied. The CTV, small bowel, colon, bladder, pelvic bone marrow, and femoral head and neck were contoured on consecutive axial slices of CT images. Two 3DCRT and three conventional treatment planning protocols were simulated using three dimensional treatment planning system (CMS Focus 2.31), were defined as 3D-3, 3D-4, 2D-2, 2D-3, 2D-4. The difference of five treatment planning protocols on the CTV and normal structure by analysis of dose-volume histograms (DVHs) were compared. Results: The D 95 and V 95 of these five protocols all exceeded 97%. The conformity index(CI) of 3D was obviously larger than that of 2D protocol. The dose inhomogeneity(DI) in 4 DCRT was less than that of 3 DCRT. The 3D as compared with the 2D, significantly reduced the mean dose of 45 Gy to the small bowel and colon. The 3D-3 as compared with the 2D-3, the 3D-4 as compared with the 2D-4, the mean dose of small bowel and colon was reduced by 28.5% and 25.7%, respectively. The 3D-3 as compared with the 2D-2, the 3D-3 as compared with the 2D-3 and the 3D4 as compared with the 2D-4, the percentage volume of small bowel and colon which received 45 Gy was reduced by 80.8% , 51.1% and 54.7% , respectively. Either the mean dose, or the percentage volume receiving 35 Gy and 45 Gy to the pelvic bone and bladder, the 3D planning protocols had advanage over the 2D planning protocols. The V 45 of bladder in 2D-2 planning proto- col was the highest in all planning protocols, exceeding 98%, but the highest V 45 of bladder was only 50% in the other planning protocols. Conclusions: Even though the difference in pelvic CTV of rectal cancer patients between the conventional radiotherapy and 3

  10. Treatment of primany hepatic carcinoma with three-dimensional conformal radiation therapy combined with transcatheter arterial chemoembolization

    International Nuclear Information System (INIS)

    Wu Li; Wen Xiaoping; Huang Wei

    2006-01-01

    Objective: To evaluate the effects of three-dimensional conformal radiation therapy (3DCRT) combined with transcatheter arterial chemoembolization (TACE) on stage m/IV primary hepatic carcinoma. Methods: Eighty cases of stage III/IV primary hepatic carcinoma were randomly divided into two groups: 40 cases treated with three-dimensional conformal radiation therapy combined with transcatheter arterial chemoembolization (3DCRT + TACE group) and 40 cases treated with three-dimensional conformal radiation therapy associated with hepatic arterial infusion chemotherapy (3DCRT +HAI group). Results: The response rates were 75% and 45% in 3DCRT + TACE group and 3DCRT + HAI group, respectively; and the difference between the two groups was statistically significant (P 0.05), The 0.5-, 1- and 2-year survival rates were 73% , 45% and 28% in 3DCRT + TACE group, and 45%, 25% and 13% in 3DCRT + HAI group, respectively; and the difference between the two groups was statistically significant (P 0.05). Conclusion: Three-dimensional conformal radiation therapy combined with transcatheter arterial chemoembolization improved prognosis of stage III/IV primary hepatic carcinoma. (authors)

  11. Phase II study of radiotherapy with three-dimensional conformal boost concurrent with paclitaxel and cisplatin for Stage IIIB non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Kim, Young Seok; Yoon, Sang Min; Choi, Eun Kyung; Yi, Byong Yong; Kim, Jong Hoon; Ahn, Seung Do; Lee, Sang-wook; Shin, Seong Soo; Lee, Jung Shin; Suh, Cheolwon; Kim, Sang-We; Kim, Dong Soon; Kim, Woo Sung; Park, Heon Joo; Park, Charn Il

    2005-01-01

    Purpose: To evaluate the efficacy and toxicity of concurrent chemoradiotherapy with paclitaxel/cisplatin for Stage IIIB locally advanced non-small-cell lung cancer (NSCLC). Methods and Materials: Radiotherapy was administered to a total dose of 70.2 Gy (daily fraction of 1.8 Gy, 5 days/wk), over an 8-week period, combined with chemotherapy. The chemotherapy consisted of weekly 40 mg/m 2 of paclitaxel plus 20 mg/m 2 of cisplatin for 8 consecutive weeks. All patients received three-dimensional conformal radiotherapy (3D-CRT), based on computed tomography simulated planning after 41.4 Gy. The median follow-up period of survivors was 24 months. Results: Between January 2000 and October 2002, 135 patients with a median age of 60 years were enrolled and analyzed in this prospective trial. The overall response rate was 75% including 2 cases of complete response. The major patterns of failure were local failure and distant metastasis. The 2-year overall and progression-free survival rates were 37% and 18%, respectively. The median overall and progression-free survival times were 17 months and 9 months, respectively. Hematologic toxicity >Grade 2 was observed in 19% of patients and severe non-hematologic toxicity was infrequent. Conclusions: Three-dimensional conformal radiotherapy, combined with paclitaxel and cisplatin chemotherapy, was associated with a satisfactory outcome with manageable toxicity. Further investigations are needed to improve the local control

  12. Commentary on "Patient-reported outcomes after 3-dimensional conformal, intensity-modulated, or proton beam radiotherapy for localized prostate cancer." Gray PJ, Paly JJ, Yeap BY, Sanda MG, Sandler HM, Michalski JM, Talcott JA, Coen JJ, Hamstra DA, Shipley WU, Hahn SM, Zietman AL, Bekelman JE, Efstathiou JA. Harvard Radiation Oncology Program, Boston, MA.: Cancer 2013;119(9):1729-35. doi: 10.1002/cncr.27956. [Epub 2013 Feb 22].

    Science.gov (United States)

    Gottschalk, Alexander

    2014-04-01

    Recent studies have suggested differing toxicity patterns for patients with prostate cancer who receive treatment with 3-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), or proton beam therapy (PBT). The authors reviewed patient-reported outcomes data collected prospectively using validated instruments that assessed bowel and urinary quality of life (QOL) for patients with localized prostate cancer who received 3DCRT (n = 123), IMRT (n = 153) or PBT (n = 95). Clinically meaningful differences in mean QOL scores were defined as those exceeding half the standard deviation of the baseline mean value. Changes from baseline were compared within groups at the first post-treatment follow-up (2-3 months from the start of treatment) and at 12 months and 24 months. At the first post-treatment follow-up, patients who received 3DCRT and IMRT, but not those who received PBT, reported a clinically meaningful decrement in bowel QOL. At 12 months and 24 months, all 3 cohorts reported clinically meaningful decrements in bowel QOL. Patients who received IMRT reported clinically meaningful decrements in the domains of urinary irritation/obstruction and incontinence at the first post-treatment follow-up. At 12 months, patients who received PBT, but not those who received IMRT or 3DCRT, reported a clinically meaningful decrement in the urinary irritation/obstruction domain. At 24 months, none of the 3 cohorts reported clinically meaningful changes in urinary QOL. Patients who received 3DCRT, IMRT, or PBT reported distinct patterns of treatment-related QOL. Although the timing of toxicity varied between the cohorts, patients reported similar modest QOL decrements in the bowel domain and minimal QOL decrements in the urinary domains at 24 months. Prospective randomized trials are needed to further examine these differences. © 2013 Published by Elsevier Inc.

  13. Assessment of improved organ at risk sparing for advanced cervix carcinoma utilizing precision radiotherapy techniques

    Energy Technology Data Exchange (ETDEWEB)

    Georg, D.; Georg, P.; Hillbrand, M.; Poetter, R.; Mock, U. [Dept. of Radiotherapy, Medical Univ. AKH, Vienna (Austria)

    2008-11-15

    Purpose: to evaluate the potential benefit of proton therapy and photon based intensity-modulated radiotherapy in comparison to 3-D conformal photon radiotherapy (3D-CRT) in locally advanced cervix cancer. Patients and methods: in five patients with advanced cervix cancer 3D-CRT (four-field box) was compared with intensity modulated photon (IMXT) and proton therapy (IMPT) as well as proton beam therapy (PT) based on passive scattering. Planning target volumes (PTVs) included primary tumor and pelvic and para-aortic lymph nodes. Dose-volume histograms (DVHs) were analyzed for the PTV and various organs at risk (OARs) (rectal wall, bladder, small bowel, colon, femoral heads, and kidneys). In addition dose conformity, dose inhomogeneity and overall volumes of 50% isodoses were assessed. Results: all plans were comparable concerning PTV parameters. Large differences between photon and proton techniques were seen in volumes of the 50% isodoses and conformity indices. DVH for colon and small bowel were significantly improved with PT and IMPT compared to IMXT, with D{sub mean} reductions of 50-80%. Doses to kidneys and femoral heads could also be substantially reduced with PT and IMPT. Sparing of rectum and bladder was superior with protons as well but less pronounced. Conclusion: proton beam RT has significant potential to improve treatment related side effects in the bowel compared to photon beam RT in patients with advanced cervix carcinoma. (orig.)

  14. Assessment of improved organ at risk sparing for advanced cervix carcinoma utilizing precision radiotherapy techniques

    International Nuclear Information System (INIS)

    Georg, D.; Georg, P.; Hillbrand, M.; Poetter, R.; Mock, U.

    2008-01-01

    Purpose: to evaluate the potential benefit of proton therapy and photon based intensity-modulated radiotherapy in comparison to 3-D conformal photon radiotherapy (3D-CRT) in locally advanced cervix cancer. Patients and methods: in five patients with advanced cervix cancer 3D-CRT (four-field box) was compared with intensity modulated photon (IMXT) and proton therapy (IMPT) as well as proton beam therapy (PT) based on passive scattering. Planning target volumes (PTVs) included primary tumor and pelvic and para-aortic lymph nodes. Dose-volume histograms (DVHs) were analyzed for the PTV and various organs at risk (OARs) (rectal wall, bladder, small bowel, colon, femoral heads, and kidneys). In addition dose conformity, dose inhomogeneity and overall volumes of 50% isodoses were assessed. Results: all plans were comparable concerning PTV parameters. Large differences between photon and proton techniques were seen in volumes of the 50% isodoses and conformity indices. DVH for colon and small bowel were significantly improved with PT and IMPT compared to IMXT, with D mean reductions of 50-80%. Doses to kidneys and femoral heads could also be substantially reduced with PT and IMPT. Sparing of rectum and bladder was superior with protons as well but less pronounced. Conclusion: proton beam RT has significant potential to improve treatment related side effects in the bowel compared to photon beam RT in patients with advanced cervix carcinoma. (orig.)

  15. Feasibility of using intensity-modulated radiotherapy to improve lung sparing in treatment planning for distal esophageal cancer

    International Nuclear Information System (INIS)

    Chandra, Anurag; Guerrero, Thomas M.; Liu, H. Helen; Tucker, Susan L.; Liao Zhongxing; Wang Xiaochun; Murshed, Hasan; Bonnen, Mark D.; Garg, Amit K.; Stevens, Craig W.; Chang, Joe Y.; Jeter, Melinda D.; Mohan, Radhe; Cox, James D.; Komaki, Ritsuko

    2005-01-01

    Background and purpose: To evaluate the feasibility whether intensity-modulated radiotherapy (IMRT) can be used to reduce doses to normal lung than three-dimensional conformal radiotherapy (3DCRT) in treating distal esophageal malignancies. Patients and methods: Ten patient cases with cancer of the distal esophagus were selected for a retrospective treatment-planning study. IMRT plans using four, seven, and nine beams (4B, 7B, and 9B) were developed for each patient and compared with the 3DCRT plan used clinically. IMRT and 3DCRT plans were evaluated with respect to PTV coverage and dose-volumes to irradiated normal structures, with statistical comparison made between the two types of plans using the Wilcoxon matched-pair signed-rank test. Results: IMRT plans (4B, 7B, 9B) reduced total lung volume treated above 10 Gy (V 1 ), 20 Gy (V 2 ), mean lung dose (MLD), biological effective volume (V eff ), and lung integral dose (P 1 , 5% for V 2 , and 2.5 Gy for MLD. IMRT improved the PTV heterogeneity (P<0.05), yet conformity was better with 7B-9B IMRT plans. No clinically meaningful differences were observed with respect to the irradiated volumes of spinal cord, heart, liver, or total body integral doses. Conclusions: Dose-volume of exposed normal lung can be reduced with IMRT, though clinical investigations are warranted to assess IMRT treatment outcome of esophagus cancers

  16. Left-sided breast cancer irradiation using rotational and fixed-field radiotherapy

    International Nuclear Information System (INIS)

    Qi, X. Sharon; Liu, Tian X.; Liu, Arthur K.; Newman, Francis; Rabinovitch, Rachel; Kavanagh, Brian; Hu, Y. Angie

    2014-01-01

    The 3-dimensional conformal radiotherapy (3DCRT) technique is the standard for breast cancer radiotherapy. During treatment planning, not only the coverage of the planning target volume (PTV) but also the minimization of the dose to critical structures, such as the lung, heart, and contralateral breast tissue, need to be considered. Because of the complexity and variations of patient anatomy, more advanced radiotherapy techniques are sometimes desired to better meet the planning goals. In this study, we evaluated external-beam radiation treatment techniques for left breast cancer using various delivery platforms: fixed-field including TomoDirect (TD), static intensity-modulated radiotherapy (sIMRT), and rotational radiotherapy including Elekta volumetric-modulated arc therapy (VMAT) and tomotherapy helical (TH). A total of 10 patients with left-sided breast cancer who did or did not have positive lymph nodes and were previously treated with 3DCRT/sIMRT to the entire breast were selected, their treatment was planned with Monaco VMAT, TD, and TH. Dosimetric parameters including PTV coverage, organ-at-risk (OAR) sparing, dose-volume histograms, and target minimum/maximum/mean doses were evaluated. It is found that for plans providing comparable PTV coverage, the Elekta VMAT plans were generally more inhomogeneous than the TH and TD plans. For the cases with regional node involvement, the average mean doses administered to the heart were 9.2 (± 5.2) and 8.8 (± 3.0) Gy in the VMAT and TH plans compared with 11.9 (± 6.4) and 11.8 (± 9.2) Gy for the 3DCRT and TD plans, respectively, with slightly higher doses given to the contralateral lung or breast or both. On average, the total monitor units for VMAT plans are 11.6% of those TH plans. Our studies have shown that VMAT and TH plans offer certain dosimetric advantages over fixed-field IMRT plans for advanced breast cancer requiring regional nodal treatment. However, for early-stage breast cancer fixed

  17. Late rectal toxicity: dose-volume effects of conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Huang, Eugene H.; Pollack, Alan; Levy, Larry; Starkschall, George; Lei Dong; Rosen, Isaac; Kuban, Deborah A.

    2002-01-01

    Purpose: To identify dosimetric, anatomic, and clinical factors that correlate with late rectal toxicity after three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Methods and Materials: We retrospectively analyzed the dose-volume histograms and clinical records of 163 Stage T1b-T3c prostate cancer patients treated between 1992 and 1999 with 3D-CRT, to a total isocenter dose of 74-78 Gy at The University of Texas M. D. Anderson Cancer Center. The median follow-up was 62 months (range 24-102). All late rectal complications were scored using modified Radiation Therapy Oncology Group and Late Effects Normal Tissue Task Force criteria. The 6-year toxicity rate was assessed using Kaplan-Meier analysis and the log-rank test. A univariate proportional hazards regression model was used to test the correlation between Grade 2 or higher toxicity and the dosimetric, anatomic, and clinical factors. In a multivariate regression model, clinical factors were added to the dosimetric and anatomic variables to determine whether they significantly altered the risk of developing late toxicity. Results: At 6 years, the rate of developing Grade 2 or higher late rectal toxicity was 25%. A significant volume effect was observed at rectal doses of 60, 70, 75.6, and 78 Gy, and the risk of developing rectal complications increased exponentially as greater volumes were irradiated. Although the percentage of rectal volume treated correlated significantly with the incidence of rectal complications at all dose levels (p 3 of the rectum. Of the clinical variables tested, only a history of hemorrhoids correlated with rectal toxicity (p=0.003). Multivariate analysis showed that the addition of hemorrhoids increased the risk of toxicity for each dosimetric variable found to be significant on univariate analysis (p<0.05 for all comparisons). Conclusion: Dose-volume histogram analyses clearly indicated a volume effect on the probability of developing late rectal complications

  18. Accelerated partial breast irradiation with external beam three-dimensional conformal radiotherapy. Five-year results of a prospective phase II clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Mozsa, Emoeke [National Institute of Oncology, Centre of Radiotherapy, Budapest (Hungary); Landesklinikum Wiener Neustadt, Department of Radiooncology and Radiotherapy, Wiener Neustadt (Austria); Meszaros, Norbert; Major, Tibor; Froehlich, Georgina; Stelczer, Gabor; Fodor, Janos; Polgar, Csaba [National Institute of Oncology, Centre of Radiotherapy, Budapest (Hungary); Sulyok, Zoltan [National Institute of Oncology, Centre of Surgery, Budapest (Hungary)

    2014-05-15

    The aim of this study was to report the 5-year results of accelerated partial breast irradiation (APBI) using external beam three-dimensional conformal radiotherapy (3D-CRT). Between 2006 and 2011, 44 patients with low-risk, stage I-II breast cancer underwent breast-conserving surgery. Postoperative APBI was given by means of 3D-CRT using three to five non-coplanar fields. The total dose of APBI was 36.9 Gy (nine fractions of 4.1 Gy b.i.d.). The mean follow-up time was 58.2 months for surviving patients. Survival results, side effects, and cosmetic results were assessed. One (2.3 %) local recurrence was observed, for a 5-year actuarial rate of 3.7 %. Neither regional nor distant failure was observed. Two patients died of internal disease. The 5-year disease-free, cancer-specific, and overall survival rates were 96.3, 100, and 95.1 %, respectively. Acute side effects included grade 1 (G1) erythema in 75 %, G1 parenchymal induration in 46 %, and G1 pain in 46 % of patients. No G2 or higher acute side effect occurred. Late side effects included G1, G2, and G3 fibrosis in 44, 7, and 2 % of patients, respectively, G1 skin pigmentation in 12 %, and G1 pain in 2 %. Asymptomatic fat necrosis occurred in 14 %. Cosmetic results were rated excellent or good in 86 % of cases by the patients themselves and 84 % by the physicians. The 5-year local tumor control, toxicity profile, and cosmetic results of APBI delivered with external beam 3D-CRT are encouraging and comparable to other APBI series. (orig.) [German] Evaluation der 5-Jahres-Ergebnisse bezueglich Ueberleben, Tumorkontrolle, Nebenwirkungen und Kosmetik nach Teilbrustbestrahlung (APBI) mittels 3-D-konformaler, akzelerierter Radiotherapie (3D-CRT). Zwischen 2006 und 2011 wurden 44 Patienten mit Brustkrebs im Stadium I-II und niedrigem Risikoprofil brusterhaltend operiert. Die adjuvante, 3-D-konformale APBI wurde mittels 3-5 nonkoplanarer Feldern durchgefuehrt. Die Gesamtdosis betrug 36,9 Gy bei 9 -mal 4,1 Gy b.i.d.. Nach

  19. Results of different modes conformal radiotherapy in treatment of cervical cancer

    International Nuclear Information System (INIS)

    Baranovs'ka, L.M.; Yivankova, V.S.; Khrulenko, T.V.; Skomorokhova, T.V.; Gorelyina, G.L.

    2017-01-01

    Development of techniques for cytotoxic treatment applying different modes of conformal radiotherapy, brachytherapy and high-energy (high dose rate - HDR) is one of the promising areas of optimization and efficiency of conservative treatment of patients with regional forms of cervical cancer. At Radiation Oncology Department, National Cancer Institute, 89 patients with stage 2b-3b cervical cancer, aged 29 to 70, underwent examination and combined radiotherapy course. The patients were divided into 2 main groups (56 patients) depending on the mode of developed conformal radiation therapy, and a control group made up by 33 patients (classic, default conformal radiotherapy). Results. Along with external beam radiotherapy, the patients of Group 2 were provided with conformal radiotherapy carried out by means of the linear accelerator of electrons in the mode of enhanced multi fractionation of irradiation dose applied to the small pelvis area (tumor and lymph efflux channels) with the single tumor dose 1.3 Gy twice per day once 4-6 hours up to the total radiation dose of 45 Gy applied to the small pelvis lymph nodes. The patients of Group 1 and the ones of the control group underwent conformal radiotherapy in the mode of standard fractionation applied to the small pelvis area with the single tumor dose of 1.8 Gy up to the total radiation dose of 45 Gy. Conformal radiotherapy was carried out for the patients of Group 1 associated with chemoradiomodifiers (tegafur, cisplatin). At the stage 2 of combined radiotherapy course, all patients underwent HDR brachytherapy via Co60 source in the mode of the single tumor dose of 5 Gy at point A up to the total radiation dose of 35-40 Gy. Therefore, employing accelerated mode of multifractiation in conformal radiotherapy of patients with regional cervical cancer makes it possible to enhance canrcinocidal irradiation doses applied to a tumor, and an interval between radiotherapy fractions provides conditions for initiation of

  20. Parotid gland-recovery after radiotherapy in the head and neck region - 36 months follow-up of a prospective clinical study

    Directory of Open Access Journals (Sweden)

    Vordermark Dirk

    2011-09-01

    Full Text Available Abstract Background The aim of the present study was to evaluate the recovery potential of the parotid glands after using either 3D-conformal-radiotherapy (3D-CRT or intensity-modulated radiotherapy (IMRT by sparing one single parotid gland. Methods Between 06/2002 and 10/2008, 117 patients with head and neck cancer were included in this prospective, non-randomised clinical study. All patients were treated with curative intent. Salivary gland function was assessed by measuring stimulated salivary flow at the beginning, during and at the end of radiotherapy as well as 1, 6, 12, 24, and 36 months after treatment. Measurements were converted to flow rates and normalized relative to rates before treatment. Mean doses (Dmean were calculated from dose-volume histograms based on computed tomographies of the parotid glands. Results Patients were grouped according to the Dmean of the spared parotid gland having the lowest radiation exposure: Group I - Dmean mean 26-40 Gy (n = 45, and group III - Dmean > 40 Gy (n = 36. 15/117 (13% patients received IMRT. By using IMRT as compared to 3D-CRT the Dmean of the spared parotid gland could be significantly reduced (Dmean IMRT vs. 3D-CRT: 21.7 vs. 34.4 Gy, p Conclusions If a Dmean mean of the parotids, and thus on the saliva flow and recovery of parotid gland.

  1. Helical tomo-therapy in the anal canal cancer: dosimetric comparison with conformal radiotherapy with intensity modulation and classical conformal radiotherapy

    International Nuclear Information System (INIS)

    Ozsahin, M.; Ugurluer, G.; Ballerini, G.; Letenneur, G.; Zouhair, A.; Mirimanoff, R.O.

    2009-01-01

    A dosimetry comparison was made between helical tomo-therapy, I.M.R.T. and classical conformal three dimensional radiotherapy for twelve first patients that received a image guided radiotherapy, the toxicity was tackled with a minimum follow-up of fourteen months. In conclusion, the CT-guided radiotherapy allows to save organs at risks superior to I.M.R.T. and conformal radiotherapy and a best homogeneity in the target volume. the toxicity is moderated and the break time is limited. (N.C.)

  2. Intensity modulated radiotherapy in early stage Hodgkin lymphoma patients: Is it better than three dimensional conformal radiotherapy?

    International Nuclear Information System (INIS)

    De Sanctis, Vitaliana; Chiacchiararelli, Laura; Enrici, Riccardo Maurizi; Bolzan, Chiara; D’Arienzo, Marco; Bracci, Stefano; Fanelli, Alessandro; Cox, Maria Christina; Valeriani, Maurizio; Osti, Mattia F; Minniti, Giuseppe

    2012-01-01

    Cure rate of early Hodgkin Lymphoma are high and avoidance of late toxicities is of paramount importance. This comparative study aims to assess the normal tissue sparing capability of intensity-modulated radiation therapy (IMRT) versus standard three-dimensional conformal radiotherapy (3D-CRT) in terms of dose-volume parameters and normal tissue complication probability (NTCP) for different organs at risk in supradiaphragmatic Hodgkin Lymphoma (HL) patients. Ten HL patients were actually treated with 3D-CRT and all treatments were then re-planned with IMRT. Dose-volume parameters for thyroid, oesophagus, heart, coronary arteries, lung, spinal cord and breast were evaluated. Dose-volume histograms generated by TPS were analyzed to predict the NTCP for the considered organs at risk, according to different endpoints. Regarding dose-volume parameters no statistically significant differences were recorded for heart and origin of coronary arteries. We recorded statistically significant lower V30 with IMRT for oesophagus (6.42 vs 0.33, p = 0.02) and lungs (4.7 vs 0.1 p = 0.014 for the left lung and 2.59 vs 0.1 p = 0.017 for the right lung) and lower V20 for spinal cord (17.8 vs 7.2 p = 0.02). Moreover the maximum dose to the spinal cord was lower with IMRT (30.2 vs 19.9, p <0.001). Higher V10 with IMRT for thyroid (64.8 vs 95, p = 0.0019) and V5 for lungs (30.3 vs 44.8, p = 0.03, for right lung and 28.9 vs 48.1, p = 0.001 for left lung) were found, respectively. Higher V5 and V10 for breasts were found with IMRT (V5: 4.14 vs 20.6, p = 0.018 for left breast and 3.3 vs 17, p = 0.059 for right breast; V10: 2.5 vs 13.6 p = 0.035 for left breast and 1.7 vs 11, p = 0.07 for the right breast.) As for the NTCP, our data point out that IMRT is not always likely to significantly increase the NTCP to OARs. In HL male patients IMRT seems feasible and accurate while for women HL patients IMRT should be used with caution

  3. Hyperfractionated 3D conformal radiotherapy and concurrent chemotherapy for unresectable stage III non-small cell lung cancer

    International Nuclear Information System (INIS)

    Choi, E.K.; Ahn, S.D.; Yi, B.Y.; Chang, H.S.; Lee, J.H.; Suh, C.W.; Lee, J.S.; Kim, S.H.; Koh, Y.S.; Kim, W.S.; Kim, D.S.; Kim, W.D.; Sohn, K.H.

    1997-01-01

    Purpose/Objective: This phase II study has been conducted to determine the feasibility, toxicity, response rate, local control, distant metastasis, and survival of hyperfractionated 3D conformal radiotherapy and concurrent chemotherapy with mitomycin C, vinblastine, and cisplatin in unresectable stage III non-small cell lung cancer (NSCLC), and also to find the most ideal 3D conformal radiotherapy technique. Materials and Methods: From Aug 1993, 173 patients with unresectable stage III NSCLC were entered into this trial and 146 (84%) completed the treatment. Hyperfractionated radiotherapy was given to a total dose of 65-70 Gy (120 cGy/fx, bid) with concurrent 2 cycles of MVP chemotherapy (Mitomycin C 6 mg/m 2 d2 and d29, Vinblastine 6 mg/m 2 d2 and d29, Cisplatin 60 mg/m 2 d1 and d28). Of these 146 patients who completed the treatment, 78 received noncoplanar 3D conformal radiotherapy using 4-6 fields and 17 received coplanar segmented conformal radiotherapy. Clinical tumor response was assessed one month after the completion of radiotherapy by computerized tomography (CT) scan. Toxicity was graded by RTOG and SWOG criteria. Normal tissue complication probability (NTCP) for lung was calculated to find the correlation with radiation pneumonitis. Results: Nineteen (13%) had stage IIIa and 127 (87%) had IIIb disease including 16 with pleural effusion and 20 with supraclavicular lymph node metastases. Response rate was 74%, including 20% complete response and 54% partial response. With a minimum follow up of 12 months, overall survival was 60% at 1 year, 30% at 2 years and median survival was 15 months. Patients achieving a complete response (n=29) had a 2-year overall survival of 46.5% compared to 28.7% for partial responders (n=79) (p=.001). Actuarial local control was 66.7% at 1 year and 43.7% at 2 years. Actuarial distant free survival was 52.3% at 1 year and 39.8% at 2 years. Major hematologic toxicity (Gr 3-4) occurred in 33% of the patients but treatment delay

  4. Results and DVH analysis of late rectal bleeding in patients treated with 3D-CRT or IMRT for localized prostate cancer

    International Nuclear Information System (INIS)

    Someya, Masanori; Hori, Masakazu; Tateoka, Kunihiko; Nakata, Kensei; Saito, Masato; Hirokawa, Naoki; Sakata, Koh-ichi; Takagi, Masaru; Hareyama, Masato

    2015-01-01

    In patients undergoing radiotherapy for localized prostate cancer, dose-volume histograms and clinical variables were examined to search for correlations between radiation treatment planning parameters and late rectal bleeding. We analyzed 129 patients with localized prostate cancer who were managed from 2002 to 2010 at our institution. They were treated with 3D conformal radiation therapy (3D-CRT, 70 Gy/35 fractions, 55 patients) or intensity-modulated radiation therapy (IMRT, 76 Gy/38 fractions, 74 patients). All radiation treatment plans were retrospectively reconstructed, dose-volume histograms of the rectum were generated, and the doses delivered to the rectum were calculated. Time to rectal bleeding ranged from 9 - 53 months, with a median of 18.7 months. Of the 129 patients, 33 patients had Grade 1 bleeding and were treated with steroid suppositories, while 25 patients with Grade 2 bleeding received argon plasma laser coagulation therapy (APC). Three patients with Grade 3 bleeding required both APC and blood transfusion. The 5-year incidence rate of Grade 2 or 3 rectal bleeding was 21.8% for the 3D-CRT group and 21.6% for the IMRT group. Univariate analysis showed significant differences in the average values from V65 to V10 between Grades 0 - 1 and Grades 2 - 3. Multivariate analysis demonstrated that patients with V65 ≥ 17% had a significantly increased risk (P = 0.032) of Grade 2 or 3 rectal bleeding. Of the 28 patients of Grade 2 or 3 rectal bleeding, 17 patients (60.7%) were cured by a single session of APC, while the other 11 patients required two sessions. Thus, none of the patients had any further rectal bleeding after the second APC session. (author)

  5. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    Science.gov (United States)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-01-01

    Introduction Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. Methods A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. Results The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. Conclusion The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques. PMID:26229623

  6. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    International Nuclear Information System (INIS)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-01-01

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques

  7. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT).

    Science.gov (United States)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-12-01

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147-53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose-volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques.

  8. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    Energy Technology Data Exchange (ETDEWEB)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham [Andrew Love Cancer Centre, Geelong Hospital, Geelong, Victoria (Australia)

    2013-12-15

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques.

  9. Radiation dose verification using real tissue phantom in modern radiotherapy techniques

    International Nuclear Information System (INIS)

    Gurjar, Om Prakash; Mishra, S.P.; Bhandari, Virendra; Pathak, Pankaj; Patel, Prapti; Shrivastav, Garima

    2014-01-01

    In vitro dosimetric verification prior to patient treatment has a key role in accurate and precision radiotherapy treatment delivery. Most of commercially available dosimetric phantoms have almost homogeneous density throughout their volume, while real interior of patient body has variable and varying densities inside. In this study an attempt has been made to verify the physical dosimetry in actual human body scenario by using goat head as 'head phantom' and goat meat as 'tissue phantom'. The mean percentage variation between planned and measured doses was found to be 2.48 (standard deviation (SD): 0.74), 2.36 (SD: 0.77), 3.62 (SD: 1.05), and 3.31 (SD: 0.78) for three-dimensional conformal radiotherapy (3DCRT) (head phantom), intensity modulated radiotherapy (IMRT; head phantom), 3DCRT (tissue phantom), and IMRT (tissue phantom), respectively. Although percentage variations in case of head phantom were within tolerance limit (< ± 3%), but still it is higher than the results obtained by using commercially available phantoms. And the percentage variations in most of cases of tissue phantom were out of tolerance limit. On the basis of these preliminary results it is logical and rational to develop radiation dosimetry methods based on real human body and also to develop an artificial phantom which should truly represent the interior of human body. (author)

  10. Radiation dose verification using real tissue phantom in modern radiotherapy techniques

    Directory of Open Access Journals (Sweden)

    Om Prakash Gurjar

    2014-01-01

    Full Text Available In vitro dosimetric verification prior to patient treatment has a key role in accurate and precision radiotherapy treatment delivery. Most of commercially available dosimetric phantoms have almost homogeneous density throughout their volume, while real interior of patient body has variable and varying densities inside. In this study an attempt has been made to verify the physical dosimetry in actual human body scenario by using goat head as "head phantom" and goat meat as "tissue phantom". The mean percentage variation between planned and measured doses was found to be 2.48 (standard deviation (SD: 0.74, 2.36 (SD: 0.77, 3.62 (SD: 1.05, and 3.31 (SD: 0.78 for three-dimensional conformal radiotherapy (3DCRT (head phantom, intensity modulated radiotherapy (IMRT; head phantom, 3DCRT (tissue phantom, and IMRT (tissue phantom, respectively. Although percentage variations in case of head phantom were within tolerance limit (< ± 3%, but still it is higher than the results obtained by using commercially available phantoms. And the percentage variations in most of cases of tissue phantom were out of tolerance limit. On the basis of these preliminary results it is logical and rational to develop radiation dosimetry methods based on real human body and also to develop an artificial phantom which should truly represent the interior of human body.

  11. Intensity-modulated proton therapy, volumetric-modulated arc therapy, and 3D conformal radiotherapy in anaplastic astrocytoma and glioblastoma. A dosimetric comparison

    Energy Technology Data Exchange (ETDEWEB)

    Adeberg, S.; Debus, J. [Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg (Germany); Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg (Germany); University Hospital Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); German Cancer Research Center (DKFZ), Clinical Cooperation Unit Radiation Oncology, Heidelberg (Germany); Harrabi, S.B.; Bougatf, N.; Rieber, J.; Koerber, S.A.; Herfarth, K.; Rieken, S. [Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg (Germany); Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg (Germany); University Hospital Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Bernhardt, D.; Syed, M.; Sprave, T.; Mohr, A. [Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg (Germany); University Hospital Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Abdollahi, A. [University Hospital Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Haberer, T. [Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg (Germany); Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg (Germany); Combs, S.E. [Technische Universitaet Muenchen, Department of Radiation Oncology, Muenchen (Germany); Helmholtz Zentrum Muenchen, Institut fuer Innovative Radiotherapie (iRT), Department of Radiation Sciences (DRS), Neuherberg (Germany)

    2016-11-15

    The prognosis for high-grade glioma (HGG) patients is poor; thus, treatment-related side effects need to be minimized to conserve quality of life and functionality. Advanced techniques such as proton radiation therapy (PRT) and volumetric-modulated arc therapy (VMAT) may potentially further reduce the frequency and severity of radiogenic impairment. We retrospectively assessed 12 HGG patients who had undergone postoperative intensity-modulated proton therapy (IMPT). VMAT and 3D conformal radiotherapy (3D-CRT) plans were generated and optimized for comparison after contouring crucial neuronal structures important for neurogenesis and neurocognitive function. Integral dose (ID), homogeneity index (HI), and inhomogeneity coefficient (IC) were calculated from dose statistics. Toxicity data were evaluated. Target volume coverage was comparable for all three modalities. Compared to 3D-CRT and VMAT, PRT showed statistically significant reductions (p < 0.05) in mean dose to whole brain (-20.2 %, -22.7 %); supratentorial (-14.2 %, -20,8 %) and infratentorial (-91.0 %, -77.0 %) regions; brainstem (-67.6 %, -28.1 %); pituitary gland (-52.9 %, -52.5 %); contralateral hippocampus (-98.9 %, -98.7 %); and contralateral subventricular zone (-62.7 %, -66.7 %, respectively). Fatigue (91.7 %), radiation dermatitis (75.0 %), focal alopecia (100.0 %), nausea (41.7 %), cephalgia (58.3 %), and transient cerebral edema (16.7 %) were the most common acute toxicities. Essential dose reduction while maintaining equal target volume coverage was observed using PRT, particularly in contralaterally located critical neuronal structures, areas of neurogenesis, and structures of neurocognitive functions. These findings were supported by preliminary clinical results confirming the safety and feasibility of PRT in HGG. (orig.) [German] Die Prognose bei ''High-grade''-Gliomen (HGG) ist infaust. Gerade bei diesen Patienten sollten therapieassoziierte Nebenwirkungen minimiert werden

  12. Patient outcomes of monotherapy with hypofractionated three-dimensional conformal radiation therapy for stage T2 or T3 non-small cell lung cancer: a retrospective study

    International Nuclear Information System (INIS)

    Sakaguchi, Masakuni; Maebayashi, Toshiya; Aizawa, Takuya; Ishibashi, Naoya; Fukushima, Shoko; Abe, Osamu; Saito, Tsutomu

    2016-01-01

    Hypofractionated three-dimensional conformal radiation therapy (3D-CRT) is a treatment option for patients with early-stage non-small cell lung cancer (NSCLC) who are medically unable to tolerate surgery and who are not amenable to treatment with stereotactic body radiotherapy. This study assessed the efficacy and safety of 3D-CRT as a monotherapy in patients with localized stage T2 or T3 NSCLC. This retrospective study consisted of 29 patients (20 males) aged 56–89 years (median, 76 years) with histologically confirmed NSCLC who underwent 3D-CRT between 2005 and 2014. The median duration of patient observation was 17.0 months (range, 1.0–64.0 months). Complete and partial responses occurred in 13.8 and 44.8 % of patients, respectively, and the overall response rate was 58.2 %. Meanwhile, the 1- and 3-year survival rates were 65.8 and 33.8 %, respectively. In T2 NSCLC, the median survival time (MST) was 12 months, and the 1- and 3-year survival rates were 62.4 and 21.4 %, respectively. In T3 NSCLC, the MST was 17 months, and the 1- and 3-year survival rates were 72.9 and 48.6 %, respectively. Severe toxicities (Common Terminology Criteria Grade 3) were not observed. The mean biologically effective dose required to improve local control exceeded 80 Gy (range, 67.2–96.0 Gy). These findings support a role for 3D-CRT as a treatment option for patients who refuse or could not tolerate surgical therapy with early-stage NSCLC. Although this was a small, retrospective study, it may form the basis for future, larger controlled studies on 3D-CRT as a monotherapy for NSCLC

  13. Late toxicity after conformal and intensity-modulated radiation therapy for prostate cancer. Impact of previous surgery for benign prostatic hyperplasia

    International Nuclear Information System (INIS)

    Odrazka, K.; Dolezel, M.; Vanasek, J.

    2010-01-01

    The objective of this study was to retrospectively compare late toxicity of conventional-dose three-dimensional conformal radiation therapy (3D-CRT) and high-dose intensity-modulated radiation therapy (IMRT) for prostate cancer. A total of 340 patients with T1-3 prostate cancer were treated with 3D-CRT (n=228) and IMRT (n=112). The median follow-up time was 5.9 years and 3.0 years, respectively. The prescription dose was 70 Gy for 3D-CRT and 78 Gy for IMRT. Late gastrointestinal (GI) and genitourinary (GU) toxicities were graded according to the Fox Chase modification of the Radiation Therapy Oncology Group and Late Effects Normal Tissue Task Force criteria. There was no difference between 3D-CRT and IMRT in the incidence of GI and GU toxicity at 3 years. On multivariate analysis, transurethral resection of prostate/open transvesical prostatectomy (TURP/TVPE) for benign prostatic hyperplasia, carried out before radiotherapy, significantly increased the risk of Grade ≥2 GU toxicity (risk ratio 1.88). Among patients who experienced TURP/TVPE, the 5-year actuarial likelihood of Grade 2-3 urinary incontinence was 23%, compared with 9% for those without prostate surgery (P=0.01). Tolerance of 3D-CRT and IMRT was similar, despite the use of high radiation dose with IMRT. Previous TURP/TVPE increased the risk of GU toxicity. (author)

  14. Cost-benefit analysis of 3D conformal radiation therapy. Treatment of prostate cancer as a model

    International Nuclear Information System (INIS)

    Cho, K.H.; Khan, F.M.; Levitt, S.H.

    1999-01-01

    Three-dimensional conformal radiation therapy (3D-CRT) is a promising new treatment technique based on the principle that improved precision in both tumor definition and dose delivery will enhance outcomes by maximizing dose to the tumor area while minimizing dose to normal tissue. Using a cost-benefit analysis, in terms of outcomes, we first examined the overall risks and benefits of 3D-CRT. We then used the treatment of prostate cancer as a model to compare actual clinical outcomes reported between 3D-CRT and standard radiation therapy (SRT). Our analysis shows that application of 3D-CRT to the clinical setting remains difficult because of the continual difficulties of target definition, and that dose escalation cannot yet be justified on the basis of the lack of benefit found, and suggested increased late toxicity, in most of the dose escalation series compared with SRT. (orig.)

  15. Dosimetric reproduction of a left-breast 3DCRT field-in-field radiation therapy planning in an anthropomorphic and anthropometric phantom

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Luciana B., E-mail: lucibn19@yahoo.com.br, E-mail: jonymarques@uol.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem; Barsanelli, Cristiane; Geraldo, Jony M., E-mail: cbarsanelli@yahoo.com.br [Hospital Luxemburgo, Instituto Mário Penna, Belo Horizonte, MG (Brazil); Aquino, Jean Carlos; Campos, Tarcísio P. Ribeiro, E-mail: jeancarlosaquino@outlook.com, E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (UGMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    The proposal of this study was to reproduce the dosimetry established in a treatment planning system (TPS) following a 3D conformational radiation therapy (3DCRT) protocol of two parallel-opposite fields applied to the left-breast in a thorax phantom, with the use of the field-in-field technique. Computed tomography (CT) images of the anthropomorphic and anthropometric phantom of the thorax with mobile breasts were generated. This phantom was developed by the NRI / UFMG research group. The generated images were transferred to the planning system XiO version-5 for the elaboration of the breast tele therapeutic planning with 2 Gy per fraction, in 25 fractions, with prescribed dose of 50 Gy. A set of ten EBT2 radiochromic films were irradiated at different doses. The values of RGB (Red, Green, Blue) of the radiochromic films were obtained by scanning and data transformed in optical density (OD), whose values were used to construct the calibration curve. EBT2 radiochromic films were positioned outside and inside of the thorax phantom: internally in the right and left lungs, on the face of the heart, in the glandular breast tissue-equivalent (TE) and in the left breast skin. After phantom radiation at the linear accelerator 6 MV Elekta Precise reproducing the 3DCRT, the radiochromic films were digitized after 24 h of exposure. The measurements of the intensities of the films in RGB were measured in the software ImageJ, transformed in optical density and converted in bidimensional dose distributions, applying the calibration curve. The experimental dosimetric data were analyzed and compared with values generated in the TPS. In addition, graphics and dose-volume histograms (DVH) were developed. The dose measurements in the glandular-TE in breast did not present statistically significant differences in relation to values at equivalent positions generated in the TPS. The organs at risk received doses below the reference values, according to TPS. It was verified the

  16. Dosimetric reproduction of a left-breast 3DCRT field-in-field radiation therapy planning in an anthropomorphic and anthropometric phantom

    International Nuclear Information System (INIS)

    Nogueira, Luciana B.; Aquino, Jean Carlos; Campos, Tarcísio P. Ribeiro

    2017-01-01

    The proposal of this study was to reproduce the dosimetry established in a treatment planning system (TPS) following a 3D conformational radiation therapy (3DCRT) protocol of two parallel-opposite fields applied to the left-breast in a thorax phantom, with the use of the field-in-field technique. Computed tomography (CT) images of the anthropomorphic and anthropometric phantom of the thorax with mobile breasts were generated. This phantom was developed by the NRI / UFMG research group. The generated images were transferred to the planning system XiO version-5 for the elaboration of the breast tele therapeutic planning with 2 Gy per fraction, in 25 fractions, with prescribed dose of 50 Gy. A set of ten EBT2 radiochromic films were irradiated at different doses. The values of RGB (Red, Green, Blue) of the radiochromic films were obtained by scanning and data transformed in optical density (OD), whose values were used to construct the calibration curve. EBT2 radiochromic films were positioned outside and inside of the thorax phantom: internally in the right and left lungs, on the face of the heart, in the glandular breast tissue-equivalent (TE) and in the left breast skin. After phantom radiation at the linear accelerator 6 MV Elekta Precise reproducing the 3DCRT, the radiochromic films were digitized after 24 h of exposure. The measurements of the intensities of the films in RGB were measured in the software ImageJ, transformed in optical density and converted in bidimensional dose distributions, applying the calibration curve. The experimental dosimetric data were analyzed and compared with values generated in the TPS. In addition, graphics and dose-volume histograms (DVH) were developed. The dose measurements in the glandular-TE in breast did not present statistically significant differences in relation to values at equivalent positions generated in the TPS. The organs at risk received doses below the reference values, according to TPS. It was verified the

  17. Phase I Study of Concurrent High-Dose Three-Dimensional Conformal Radiotherapy With Chemotherapy Using Cisplatin and Vinorelbine for Unresectable Stage III Non-Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sekine, Ikuo, E-mail: isekine@ncc.go.jp [Division of Internal Medicine and Thoracic Oncology, National Cancer Center Hospital, Tokyo (Japan); Sumi, Minako; Ito, Yoshinori [Division of Radiation Oncology, National Cancer Center Hospital, Tokyo (Japan); Horinouchi, Hidehito; Nokihara, Hiroshi; Yamamoto, Noboru; Kunitoh, Hideo; Ohe, Yuichiro; Kubota, Kaoru; Tamura, Tomohide [Division of Internal Medicine and Thoracic Oncology, National Cancer Center Hospital, Tokyo (Japan)

    2012-02-01

    Purpose: To determine the maximum tolerated dose in concurrent three-dimensional conformal radiotherapy (3D-CRT) with chemotherapy for unresectable Stage III non-small-cell lung cancer (NSCLC). Patients and Methods: Eligible patients with unresectable Stage III NSCLC, age {>=}20 years, performance status 0-1, percent of volume of normal lung receiving 20 GY or more (V{sub 20}) {<=}30% received three to four cycles of cisplatin (80 mg/m{sup 2} Day 1) and vinorelbine (20 mg/m{sup 2} Days 1 and 8) repeated every 4 weeks. The doses of 3D-CRT were 66 Gy, 72 Gy, and 78 Gy at dose levels 1 to 3, respectively. Results: Of the 17, 16, and 24 patients assessed for eligibility, 13 (76%), 12 (75%), and 6 (25%) were enrolled at dose levels 1 to 3, respectively. The main reasons for exclusion were V{sub 20} >30% (n = 10) and overdose to the esophagus (n = 8) and brachial plexus (n = 2). There were 26 men and 5 women, with a median age of 60 years (range, 41-75). The full planned dose of radiotherapy could be administered to all the patients. Grade 3-4 neutropenia and febrile neutropenia were noted in 24 (77%) and 5 (16%) of the 31 patients, respectively. Grade 4 infection, Grade 3 esophagitis, and Grade 3 pulmonary toxicity were noted in 1 patient, 2 patients, and 1 patient, respectively. The dose-limiting toxicity was noted in 17% of the patients at each dose level. The median survival and 3-year and 4-year survival rates were 41.9 months, 72.3%, and 49.2%, respectively. Conclusions: 72 Gy was the maximum dose that could be achieved in most patients, given the predetermined normal tissue constraints.

  18. Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer

    International Nuclear Information System (INIS)

    Herrassi, Mohamed Yassine; Bentayeb, Farida; Malisan, Maria Rosa

    2013-01-01

    For the head-and-neck cancer bilateral irradiation, intensity-modulated radiation therapy (IMRT) is the most reported technique as it enables both target dose coverage and organ-at-risk (OAR) sparing. However, during the last 20 years, three-dimensional conformal radiotherapy (3DCRT) techniques have been introduced, which are tailored to improve the classic shrinking field technique, as regards both planning target volume (PTV) dose conformality and sparing of OARs, such as parotid glands and spinal cord. In this study, we tested experimentally in a sample of 13 patients, four of these advanced 3DCRT techniques, all using photon beams only and a unique isocentre, namely Bellinzona, Forward-Planned Multisegments (FPMS), ConPas, and field-in-field (FIF) techniques. Statistical analysis of the main dosimetric parameters of PTV and OARs DVHs as well as of homogeneity and conformity indexes was carried out in order to compare the performance of each technique. The results show that the PTV dose coverage is adequate for all the techniques, with the FPMS techniques providing the highest value for D95%; on the other hand, the best sparing of parotid glands is achieved using the FIF and ConPas techniques, with a mean dose of 26 Gy to parotid glands for a PTV prescription dose of 54 Gy. After taking into account both PTV coverage and parotid sparing, the best global performance was achieved by the FIF technique with results comparable to that of IMRT plans. This technique can be proposed as a valid alternative when IMRT equipment is not available or patient is not suitable for IMRT treatment. (author)

  19. Radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma: Dosimetric comparison and risk assessment of solid secondary cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Sun Hyun; Park, Hee Chul; Lim, Do Hoon [Dept. of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Dong Wook [Dept. of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of); Kim, Mi Sook [Dept. of Radiation Oncology, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Shin, Myung Hee [Dept. of Social and Preventive Medicine, Sungkyunkwan University School of Medicine, Suwon (Korea, Republic of)

    2017-03-15

    We compared the dosimetric parameters and the risk of solid secondary cancer from scattered doses among anterior-posterior/posterior-anterior parallel-opposed fields (AP/PA), anterior, posterior, right, and left lateral fields (4{sub f}ield), 3-dimensional conformal radiotherapy (3D-CRT) using noncoplanar beams, and intensity-modulated radiotherapy composed of 7 coplanar beams (IMRT{sub c}o) and 7 coplanar and noncoplanar beams (IMRT{sub n}on). We retrospectively generated 5 planning techniques for 5 patients with gastric MALToma. Homogeneity index (HI), conformity index (CI), and mean doses of the kidney and liver were calculated from the dose-volume histograms. Applied the Biological Effects of Ionizing Radiation VII report to scattered doses, the lifetime attributable risk (LAR) was calculated to estimate the risk of solid secondary cancer. The best value of CI was obtained with IMRT, although the HI varied among patients. The mean kidney dose was the highest with AP/PA, followed by 4{sub f}ield, 3D-CRT, IMRT{sub c}o, and IMRT{sub n}on. On the other hand, the mean liver dose was the highest with 4{sub f}ield and the lowest with AP/PA. Compared with 4{sub f}ield, the LAR for 3D-CRT decreased except the lungs, and the LAR for IMRT{sub c}o and IMRT{sub n}on increased except the lungs. However, the absolute differences were much lower than <1%. Tailored RT techniques seem to be beneficial because it could achieve adjacent organ sparing with very small and clinically irrelevant increase of secondary solid cancer risk compared to the conventional techniques.

  20. Doses to head and neck normal tissues for early stage Hodgkin lymphoma after involved node radiotherapy

    International Nuclear Information System (INIS)

    Maraldo, M.V.; Brodin, N.P.; Aznar, M.C.; Vogelius, I.R.; Munck af Rosenschöld, P.; Petersen, P.M.; Specht, L.

    2014-01-01

    Purpose: To evaluate dose plans for head and neck organs at risk (OARs) for classical Hodgkin lymphoma (HL) patients using involved node radiotherapy (INRT) delivered as 3D conformal radiotherapy (3DCRT), volumetric modulated arc therapy (VMAT), and intensity modulated proton therapy (PT), in comparison to the past mantle field (MF). Materials and methods: Data from 37 patients with cervical lymph node involvement were used. All patients originally received chemotherapy followed by 3DCRT–INRT (30.6 Gy). A VMAT–INRT, PT–INRT (both 30.6 Gy), and a MF plan (36 Gy) were simulated. Doses to head and neck OARs were compared with cumulative DVHs and repeated measures ANOVA. Results: The estimated median mean doses were 15.3, 19.3, 15.4, and 37.3 Gy (thyroid), 10.9, 12.0, 7.9, and 34.5 Gy (neck muscles), 2.3, 11.1, 1.8, and 37.1 Gy (larynx), 1.7, 5.1, 1.3, and 23.8 Gy (pharynx), 0.5, 0.8, 0.01, and 32.3 Gy (ipsilateral parotid), and 2.4, 3.8, 0.7, and 34.7 Gy (ipsilateral submandibular) with 3DCRT, VMAT, PT, and MF (all p < 0.0001), respectively. Conclusion: The use of INRT significantly lowered the estimated radiation dose to the head and neck OARs. VMAT appeared suboptimal compared to 3DCRT and PT, and for some patients, PT offered an additional gain

  1. Induction chemotherapy combined with three-dimensional conformal radiation therapy for locally advanced non-small cell lung cancer

    International Nuclear Information System (INIS)

    Zheng Aiqing; Yu Jinming; Zhao Xianguang; Wang Xuetao; Wei Guangsheng

    2005-01-01

    Objective: To evaluate the effect and complication of induction chemotherapy combined with three-dimensional conformal radiation therapy (3DCRT) for locally advanced non small cell lung cancer (NSCLC). Methods: Ninety-two such patients were randomized into radiation therapy alone group(RT-, 50 patients) and induction chemotherapy combined radiotherapy group (CMT-, 42 patients). The induction chemotherapy consisted of 2-4 cycles of platinum-based regimen. Results: The overall median survival time was 15 months with 12 months in the RT group and 18 months in the CMT group (P=0.014) respectively. The 1-year overall survival rates were 48.6% and 71.2% in RT and CMT group, respectively (P=0.004). The 2-year survival rates were 20.8% and 37.6% in RT and CMT group, respectively (P=0.041). Treatment was well tolerated and the toxicities were similar in either group. Conclusion: The addition of induction chemotherapy to 3DCRT takes a survival advantage over 3DCRT alone for Stage III NSCLC without increasing toxicities. (authors)

  2. Outcome of three-dimensional conformal radiation therapy and intensity-modulated radiation therapy for inoperable locally advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Lu Ningning; Jin Jing; Li Yexiong; Yu Zihao; Liu Xinfan; Wang Weihu; Wang Shulian; Song Yongwen; Liu Yuping

    2009-01-01

    Objective: To evaluate the outcome of radiotherapy for locally advanced pancreatic cancer. Methods: From January 2000 to December 2007, 41 patients with inoperable locally advanced (stage III) pancreatic cancer were treated with three-dimensional conformal radiation therapy(3DCRT) or intensity-modulated radiation therapy (IMRT). Among these patients, 30 received concurrent radio-chemo-therapy. Results: The median survival time(MST) and 1-year overall survival were 9.2 months and 23%. Patients with pretreatment KPS ≥ 80, no regional lymph nodes metastasis, and CR/PR after radiotherapy had better prognosis. The corresponding MSTs were 11.1 months vs 5.8 months (χ 2 =7.50, P=0.006), 10.8 months vs 6.5 months(χ 2 =5.67, P=0.017), and 19.5 months vs 9.1 months (χ 2 =7.28, P=0.007), respectively. Concurrent radio-chemotherapy tended to improve the overall survival(χ 2 =3.25, P=0.072). After radiotherapy, 18 patients had clinical benefit response, mainly being abdominal pain relief. Neither grade 4 hematologic nor grade 3 non-hematologic toxicities were observed. Conclusions: For patients with locally advanced pancreatic cancer, both 3DCRT and IMRT are effective in alleviation of disease-related symptoms. Patients with better performance status before treatment, no regional lymph nodes metastasis, and better response to radiotherapy may have better prognosis. Concurrent radio-chemotherapy trend to improve overall survival when compared with radiotherapy alone. (authors)

  3. Intensity-modulated radiotherapy for laryngeal and hypopharyngeal cancer. Minimization of late dysphagia without jeopardizing tumor control

    Energy Technology Data Exchange (ETDEWEB)

    Modesto, Anouchka; Laprie, Anne; Graff, Pierre; Rives, Michel [Institut Universitaire du Cancer, Department of Radiation Oncology, Institut Claudius Regaud, Toulouse (France); Vieillevigne, Laure [Institut Universitaire du Cancer, Department of Medical Physics, Toulouse (France); Sarini, Jerome; Vergez, Sebastien; Farenc, Jean-Claude [Institut Universitaire du Cancer, Department of Head and Neck Surgery, Toulouse (France); Delord, Jean-Pierre [Institut Universitaire du Cancer, Department of Medical Oncology, Toulouse (France); Vigarios, Emmanuelle [Centre Hospitalo Universitaire de Rangueil, Dental Surgery Department, Toulouse (France); Filleron, Thomas [Institut Universitaire du Cancer, Department of Biostatistics, Toulouse (France)

    2014-11-01

    The purpose of this work was to retrospectively determine the value of intensity-modulated radiotherapy (IMRT) in patients with laryngeal and hypopharyngeal squamous cell carcinoma (LHSCC), on outcome and treatment-related toxicity compared to 3-dimensional conformal radiotherapy (3D-CRT). A total of 175 consecutive patients were treated between 2007 and 2012 at our institution with curative intent RT and were included in this study: 90 were treated with 3D-CRT and 85 with IMRT. Oncologic outcomes were estimated using Kaplan-Meier statistics; acute and late toxicities were scored according to the Common Toxicity Criteria for Adverse Events scale v 3.0. Median follow-up was 35 months (range 32-42 months; 95% confidence interval 95 %). Two-year disease-free survival did not vary, regardless of the technique used (69 % for 3D-CRT vs. 72 %; for IMRT, p = 0.16). Variables evaluated as severe late toxicities were all statistically lower with IMRT compared with 3D-CRT: xerostomia (0 vs. 12 %; p < 0.0001), dysphagia (4 vs. 26 %; p < 0.0001), and feeding-tube dependency (1 vs 13 %; p = 0.0044). The rates of overall grade ≥ 3 late toxicities for the IMRT and 3D-CRT groups were 4.1 vs. 41.4 %, respectively (p < 0.0001). IMRT for laryngeal and hypopharyngeal cancer minimizes late dysphagia without jeopardizing tumor control and outcome. (orig.) [German] Das Ziel dieser Studie war es, retrospektiv den Nutzen der intensitaetsmodulierten Strahlentherapie (IMRT) in der Behandlung von Patienten mit Plattenepithelkarzinom von Kehlkopf und Hypopharynx (LHSCC) zu bewerten und mit dem Outcome und den Spaetfolgen der 3-D-konformalen Strahlentherapie (3D-CRT) zu vergleichen. Insgesamt wurden zwischen Januar 2007 und Dezember 2012175 LHSCC-Patienten mit einer RT behandelt und in die Studie aufgenommen: 85 Patienten wurden mit 3D-CRT und 90 Patienten mit IMRT behandelt.Das onkologische Outcome wurde mittels Kaplan-Meier-Statistik ermittelt und Akut- und Spaettoxizitaeten anhand der CTCAE

  4. Conformation radiotherapy with eccentric multi-leaves, (1)

    International Nuclear Information System (INIS)

    Obata, Yasunori; Sakuma, Sadayuki.

    1986-01-01

    In order to extend the application of the conformation radiotherapy, the eccentric multi-leaves are equipped with the linear accelerator. The information of the position of the collimators and the dose distribution of the eccentric conformation radiotherapy are calculated by the improved algorism of the treatment planning system. In simple cases, the dose distributions for the distant region from the rotational center are measured and compared with the calculated values. Both distributions are well coincided with the error of about 5 % in the high dose region and 10 % in the low dose region. In eccentric conformation radiotherapy, it is difficult to deliver the planned dose to the lesion. The dose increases with the distance of the target area from the rotational center. And the measured value and the calculated value are well coincided with 1 % error. So after getting the dose ratio of the rotational center to the target area, the calculated dose can be delivered to the rotational center. The advantages of the eccentric conformation radiotherapy are a good coincidence of target area and treated area, a partial shielding and a hollow out technique without absorber. The limitation of the movement of the collimator from center is 5 cm at 1 m SCD. (author)

  5. Hippocampal sparing radiotherapy for glioblastoma patients: a planning study using volumetric modulated arc therapy

    International Nuclear Information System (INIS)

    Hofmaier, Jan; Kantz, Steffi; Söhn, Matthias; Dohm, Oliver S.; Bächle, Stefan; Alber, Markus; Parodi, Katia; Belka, Claus; Niyazi, Maximilian

    2016-01-01

    The purpose of this study is to investigate the potential to reduce exposure of the contralateral hippocampus in radiotherapy for glioblastoma using volumetric modulated arc therapy (VMAT). Datasets of 27 patients who had received 3D conformal radiotherapy (3D-CRT) for glioblastoma with a prescribed dose of 60Gy in fractions of 2Gy were included in this planning study. VMAT plans were optimized with the aim to reduce the dose to the contralateral hippocampus as much as possible without compromising other parameters. Hippocampal dose and treatment parameters were compared to the 3D-CRT plans using the Wilcoxon signed-rank test. The influence of tumour location and PTV size on the hippocampal dose was investigated with the Mann–Whitney-U-test and Spearman’s rank correlation coefficient. The median reduction of the contralateral hippocampus generalized equivalent uniform dose (gEUD) with VMAT was 36 % compared to the original 3D-CRT plans (p < 0.05). Other dose parameters were maintained or improved. The median V30Gy brain could be reduced by 17.9 % (p < 0.05). For VMAT, a parietal and a non-temporal tumour localisation as well as a larger PTV size were predictors for a higher hippocampal dose (p < 0.05). Using VMAT, a substantial reduction of the radiotherapy dose to the contralateral hippocampus for patients with glioblastoma is feasible without compromising other treatment parameters. For larger PTV sizes, less sparing can be achieved. Whether this approach is able to preserve the neurocognitive status without compromising the oncological outcome needs to be investigated in the setting of prospective clinical trials

  6. Involved-Site Image-Guided Intensity Modulated Versus 3D Conformal Radiation Therapy in Early Stage Supradiaphragmatic Hodgkin Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Filippi, Andrea Riccardo, E-mail: andreariccardo.filippi@unito.it [Department of Oncology, University of Torino, Torino (Italy); Ciammella, Patrizia [Radiation Therapy Unit, Department of Oncology and Advanced Technology, ASMN Hospital IRCCS, Reggio Emilia (Italy); Piva, Cristina; Ragona, Riccardo [Department of Oncology, University of Torino, Torino (Italy); Botto, Barbara [Hematology, Città della Salute e della Scienza, Torino (Italy); Gavarotti, Paolo [Hematology, University of Torino and Città della Salute e della Scienza, Torino (Italy); Merli, Francesco [Hematology Unit, ASMN Hospital IRCCS, Reggio Emilia (Italy); Vitolo, Umberto [Hematology, Città della Salute e della Scienza, Torino (Italy); Iotti, Cinzia [Radiation Therapy Unit, Department of Oncology and Advanced Technology, ASMN Hospital IRCCS, Reggio Emilia (Italy); Ricardi, Umberto [Department of Oncology, University of Torino, Torino (Italy)

    2014-06-01

    Purpose: Image-guided intensity modulated radiation therapy (IG-IMRT) allows for margin reduction and highly conformal dose distribution, with consistent advantages in sparing of normal tissues. The purpose of this retrospective study was to compare involved-site IG-IMRT with involved-site 3D conformal RT (3D-CRT) in the treatment of early stage Hodgkin lymphoma (HL) involving the mediastinum, with efficacy and toxicity as primary clinical endpoints. Methods and Materials: We analyzed 90 stage IIA HL patients treated with either involved-site 3D-CRT or IG-IMRT between 2005 and 2012 in 2 different institutions. Inclusion criteria were favorable or unfavorable disease (according to European Organization for Research and Treatment of Cancer criteria), complete response after 3 to 4 cycles of an adriamycin- bleomycin-vinblastine-dacarbazine (ABVD) regimen plus 30 Gy as total radiation dose. Exclusion criteria were chemotherapy other than ABVD, partial response after ABVD, total radiation dose other than 30 Gy. Clinical endpoints were relapse-free survival (RFS) and acute toxicity. Results: Forty-nine patients were treated with 3D-CRT (54.4%) and 41 with IG-IMRT (45.6%). Median follow-up time was 54.2 months for 3D-CRT and 24.1 months for IG-IMRT. No differences in RFS were observed between the 2 groups, with 1 relapse each. Three-year RFS was 98.7% for 3D-CRT and 100% for IG-IMRT. Grade 2 toxicity events, mainly mucositis, were recorded in 32.7% of 3D-CRT patients (16 of 49) and in 9.8% of IG-IMRT patients (4 of 41). IG-IMRT was significantly associated with a lower incidence of grade 2 acute toxicity (P=.043). Conclusions: RFS rates at 3 years were extremely high in both groups, albeit the median follow-up time is different. Acute tolerance profiles were better for IG-IMRT than for 3D-CRT. Our preliminary results support the clinical safety and efficacy of advanced RT planning and delivery techniques in patients affected with early stage HL, achieving complete

  7. Dosimetric analysis of the brachial plexus among patients with breast cancer treated with post-mastectomy radiotherapy to the ipsilateral supraclavicular area: report of 3 cases of radiation-induced brachial plexus neuropathy

    International Nuclear Information System (INIS)

    Wu, San-Gang; Huang, Si-Juan; Zhou, Juan; Sun, Jia-Yuan; Guo, Han; Li, Feng-Yan; Lin, Qin; Lin, Huan-Xin; He, Zhen-Yu

    2014-01-01

    The purpose of this study was to evaluate the brachial plexus (BP) dose of postmastectomy radiotherapy (PMRT) to the ipsilateral supraclavicular (ISCL) area, and report the characteristics of radiation-induced brachial plexus neuropathy (RIBPN). The BP dose of 31 patients who received adjuvant PMRT to the ISCL area and chest wall using three-dimensional conformal radiotherapy (3DCRT) and the records of 3 patients with RIBPN were retrospectively analyzed based on the standardized Radiation Therapy Oncology Group-endorsed guidelines. The total dose to the ISCL area and chest wall was 50 Gy in 25 fractions. Patients with a higher number of removed lymph nodes (RLNs) had a higher risk of RIBPN (hazard ratio [HR]: 1.189, 95% confidence interval [CI]: 1.005-1.406, p = 0.044). In 31 patients treated with 3DCRT, the mean dose to the BP without irradiation to the ISCL area was significantly less than that with irradiation to the ISCL area (0.97 ± 0.20 vs. 44.39 ± 4.13 Gy, t = 136.75, p <0.001). In the 3DCRT plans with irradiation to the ISCL area and chest wall, the maximum dose to the BP was negatively correlated with age (r = −0.40, p = 0.026), body mass index (BMI) (r = −0.44, p = 0.014), and body weight (r = −0.45, p = 0.011). Symptoms of the 3 patients with RIBPN occurred 37–65 months after radiotherapy, and included progressive upper extremity numbness, pain, and motor disturbance. After treatment, 1 patient was stable, and the other 2 patients’ symptoms worsened. The incidence of RIBPN was higher in patients with a higher number of RLNs after PMRT. The dose to the BP is primarily from irradiation of the ISCL area, and is higher in slim and young patients. Prevention should be the main focus of managing RIBPN, and the BP should be considered an organ-at-risk when designing a radiotherapy plan for the ISCL area

  8. Potential for Improved Intelligence Quotient Using Volumetric Modulated Arc Therapy Compared With Conventional 3-Dimensional Conformal Radiation for Whole-Ventricular Radiation in Children

    International Nuclear Information System (INIS)

    Qi, X. Sharon; Stinauer, Michelle; Rogers, Brion; Madden, Jennifer R.; Wilkening, Greta N.; Liu, Arthur K.

    2012-01-01

    Purpose: To compare volumetric modulated arc therapy (VMAT) with 3-dimensional conformal radiation therapy (3D-CRT) in the treatment of localized intracranial germinoma. We modeled the effect of the dosimetric differences on intelligence quotient (IQ). Method and Materials: Ten children with intracranial germinomas were used for planning. The prescription doses were 23.4 Gy to the ventricles followed by 21.6 Gy to the tumor located in the pineal region. For each child, a 3D-CRT and full arc VMAT was generated. Coverage of the target was assessed by computing a conformity index and heterogeneity index. We also generated VMAT plans with explicit temporal lobe sparing and with smaller ventricular margin expansions. Mean dose to the temporal lobe was used to estimate IQ 5 years after completion of radiation, using a patient age of 10 years. Results: Compared with the 3D-CRT plan, VMAT improved conformality (conformity index 1.10 vs 1.85), with slightly higher heterogeneity (heterogeneity index 1.09 vs 1.06). The averaged mean doses for left and right temporal lobes were 31.3 and 31.7 Gy, respectively, for VMAT plans and 37.7 and 37.6 Gy for 3D-CRT plans. This difference in mean temporal lobe dose resulted in an estimated IQ difference of 3.1 points at 5 years after radiation therapy. When the temporal lobes were explicitly included in the VMAT optimization, the mean temporal lobe dose was reduced 5.6-5.7 Gy, resulting in an estimated IQ difference of an additional 3 points. Reducing the ventricular margin from 1.5 cm to 0.5 cm decreased mean temporal lobe dose 11.4-13.1 Gy, corresponding to an estimated increase in IQ of 7 points. Conclusion: For treatment of children with intracranial pure germinomas, VMAT compared with 3D-CRT provides increased conformality and reduces doses to normal tissue. This may result in improvements in IQ in these children.

  9. Acute and late side-effects of conventional and conformal pelvic radiotherapy for cervical and endometrial cancer

    International Nuclear Information System (INIS)

    Izmajlowicz, B.; Komafel, J.

    2010-01-01

    Aim of the study. The purpose of this prospective study was to analyze and compare acute and late side-effects observed in patients with cervical and endometrial cancer treated with conventional 2-dimensional (2D) and conformal 3-dimensional (3D) pelvic radiotherapy. Patients and method. 50 patients treated with conventional pelvic radiotherapy and 50 patients treated with conformal pelvic radiotherapy at the Clinical Department of Gynecological Radiotherapy of the Lower Silesian Oncology Center between November 2004 and October 2005 were entered into a prospective study. We assessed Radiotherapy side-effects according to EORTCIRTOG, performance status according to the WHO, Body Mass Index and hematologic parameters during radiotherapy and one year after treatment. Results. Performance status acc. to the WHO was significantly better in the conformal arm. Anemia and nausea were more frequent in the conventional arm. In both the study groups acute gastrointestinal and genitourinary morbidity was more frequent than late morbidity and performance status was better after than before radiotherapy. Mean BMI was lower after radiotherapy than before treatment. Conclusions. Conformal pelvic radiotherapy in patients with cervical and endometrial cancer is less toxic than conventional pelvic radiotherapy which is also confirmed by the performance status. (authors)

  10. Impact of radiation dose on achieving nadir PSA levels after 3-dimensional conformal radiotherapy for patients with localized prostate cancer

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Leibel, Steven A.; Kelson, Suzanne; Fuks, Zvi

    1996-01-01

    Purpose: Several reports have documented the prognostic value of a post-irradiation nadir PSA of ≤1 ng/ml in prostatic cancer patients. The purpose of this study was to determine which pre-treatment and treatment-related variables impact upon achieving such nadir levels. Materials and Methods: Between January 1987 and June 1995, 740 patients with clinically localized prostate cancer were treated with 3-dimensional conformal radiotherapy (3D-CRT). 214 (29%) patients were treated with neo-adjuvant androgen ablation prior to therapy and were excluded from this analysis. Among the 526 evaluable patients, the clinical stage were as follows: T 1 C=128 (24%); T 2 A=76 (14%); T 2 B=116 (22%); T 2 C=99 (19%) and T 3 =107 (21%). The prescription dose to the planning target volume (PTV) was 64.8-68.4 Gy in 87 patients (17%); 70.2 Gy in 191 (36%); 75.6 Gy in 209 (40%) and 81 Gy in 39 (7%). The median pre-treatment PSA value was 11.2 ng/ml (range 0.3-114). The median follow-up was 20 months (range: 6-76 months). Results: 242 patients (46%) had PSA levels which declined to ≤1.0 ng/ml. The median time to a nadir level of ≤1.0 was 15.6 months (range: 1-43 months) from completion of 3D-CRT. 154 (29%) patients continued to show declining PSA levels within the first 2 years after therapy, and 130 patients (25%) failed to nadir at PSA levels of ≤1.0 ng/ml. Among patients with nadir PSA levels ≤1, the 3 year PSA relapse-free survival was 91% compared to 29% for patients with nadir PSA levels >1 ng/ml (p<0.0001). A Cox-regression analysis demonstrated that nadir PSA ≤1 was the strongest predictor of PSA relapse-free survival (p<0.001) followed by Gleason score ≤ 6 (p<0.001) and stage< T3 (p=0.004). Among patients who received doses of ≥75.6 Gy, the likelihood of achieving PSA nadir levels ≤1.0 at 24 and 36 months was 86% and 93%, respectively, compared to 74 and 80%, respectively, among those who received lower doses (p<0.001). Doses of ≥75.6 Gy was the strongest

  11. Psa control for dose escalation with 3DCRT in the treatment of prostate cancer

    International Nuclear Information System (INIS)

    Alvarez Sosa, Amarilys; Rodriguez, Yaima; Perez Velasquez, Reytel

    2009-01-01

    In the detection of prostate cancer PSA carry out checks on patients between 40-50 years or more. The present work has as objective to establish the procedure 'in vivo' and i n vitro , based on ISO 9000, for assessment changes in PSA levels in patients who underwent scaling the dose through the 3D-CRT. The procedure provides the steps to follow from diagnostic evaluation to the completion of treatment with 3D-CRT. Finally This document is a valuable tool in assessing the effectiveness of treatment for prostate cancer with 3D-CRT. (author)

  12. Investigation of normal tissue complication probabilities in prostate and partial breast irradiation radiotherapy techniques

    International Nuclear Information System (INIS)

    Bezak, E.; Takam, R.; Bensaleh, S.; Yeoh, E.; Marcu, L.

    2011-01-01

    Full text: Normal- Tissue-Complication Probabilities of rectum, bladder and urethra following various radiation techniques for prostate cancer were evaluated using the relative-seriality and Lyman models. NTCPs of lungs, heart and skin, their dependence on sourceposition, balloon-deformation were also investigated for HDR mammosite brachytherapy. The prostate treatment techniques included external three dimentional conformal-radiotherapy, Low-Dose-Rate brachytherapy (1-125), High-Dose-Rate brachytherapy (Ir-I92). Dose- Volume-Histograms of critical structures for prostate and breast radiotherapy, retrieved from corresponding treatment planning systems, were converted to Biological Effective Dose (BEffD)-based and Equivalent Dose(Deq)-based DVHs to account for differences in radiation delivery and fractionation schedule. Literature-based model parameters were used to calculate NTCPs. Hypofractionated 3D-CRT (2.75 Gy/fraction, total dose 55 Gy) NTCPs of rectum, bladder and urethra were less than those for standard fractionated 4-field 3D-CRT (2-Gy/fraction, 64 Gy) and dose-escalated 4- and 5-field 3D-CRT (74 Gy). Rectal and bladder NTCPs (5.2% and 6.6%) following the dose-escalated 4-field 3D-CRT (74 Gy) were the highest among analyzed techniques. The average NTCP for rectum and urethra were 0.6% and 24.7% for LDRBT and 0.5% and 11.2% for HDR-BT. For Mammosite, NTCP was estimated to be 0.1 %, 0.1 %, 1.2% and 3.5% for skin desquamation, erythema, telangiectasia and fibrosis respectively (the source positioned at the balloon centre). A 4 mm Mammosite-balloon deformation leads to overdosing of PTV regions by ∼40%, resulting in excessive skin dose and increased NTCP. Conclusions Prostate brachytherapy resulted in NTCPs lower compared to external beam techniques. Mammosite-brachytherapy resulted in no heart/lung complications regardless of balloon deformation. However, 4 mm deformation caused 0.6% increase in tissue fibrosis NTCP.

  13. A survey on the state on the use of conformation radiotherapy units in Japan

    International Nuclear Information System (INIS)

    Tomaru, Teizo; Onai, Yoshio; Abe, Shunsuke

    1985-01-01

    A survey on the stage on the use of conformation radiotherapy units in Japan was performed by the Radiotherapy Equipments Committee of the Japanese Association for Radiotherapy Systems. The questionnaire was sent to 34 hospitals, which are all the hospitals equipped with these units, and 13 cancer and adult disease centers. The answers were collected from 42 hospitals, of which the 31 from formers and 11 from latters. In June, 1984, 27 conformation radiotherapy units (11 units with a pair of lower jaws and 16 units with multi-leaf collimators) were being used at 26 hospitals answered to questionnaire. During a month from May 16 to June 15 in 1984, conformation radiotherapy was performed at 10 hopsitals, and mean number of patients per day treated with these irradiation techniques was 3.7 +- 3.5. Fixed beam radiotherapy with irregular shape fields using multi-leaf collimators was also performed at 8 hospitals and mean number of patients per day treated with this fixed beam was 6.6 +- 3.9. Hollow-out irradiation technique was used at 4 hospitals, and 3.8 patients per day per hospital were treated with this technique. (author)

  14. Treatment planning with protons for pediatric retinoblastoma, medulloblastoma, and pelvic sarcoma: How do protons compare with other conformal techniques?

    International Nuclear Information System (INIS)

    Lee, Catherine T.; Bilton, Stephen D.; Famiglietti, Robin M.; Riley, Beverly A.; Mahajan, Anita; Chang, Eric L.; Maor, Moshe H.; Woo, Shiao Y.; Cox, James D.; Smith, Alfred R.

    2005-01-01

    Purpose: To calculate treatment plans and compare the dose distributions and dose-volume histograms (DVHs) for photon three-dimensional conformal radiation therapy (3D-CRT), electron therapy, intensity-modulated radiation therapy (IMRT), and standard (nonintensity modulated) proton therapy in three pediatric disease sites. Methods and Materials: The tumor volumes from 8 patients (3 retinoblastomas, 2 medulloblastomas, and 3 pelvic sarcomas) were studied retrospectively to compare DVHs from proton therapy with 3D-CRT, electron therapy, and IMRT. In retinoblastoma, several planning techniques were analyzed: A single electron appositional beam was compared with a single 3D-CRT lateral beam, a 3D-CRT anterior beam paired with a lateral beam, IMRT, and protons. In medulloblastoma, three posterior fossa irradiation techniques were analyzed: 3D-CRT, IMRT, and protons. Craniospinal irradiation (which consisted of composite plans of both the posterior fossa and craniospinal components) was also evaluated, primarily comparing spinal irradiation using 3D-CRT electrons, 3D-CRT photons, and protons. Lastly, in pelvic sarcoma, 3D-CRT, IMRT, and proton plans were assessed. Results: In retinoblastoma, protons resulted in the best target coverage combined with the most orbital bone sparing (10% was the mean orbital bone volume irradiated at ≥5 Gy for protons vs. 25% for 3D-CRT electrons, 69% for IMRT, 41% for a single 3D lateral beam, 51% for a 3D anterolateral beam with a lens block, and 65% for a 3D anterolateral beam without a lens block). A single appositional electron field was the next best technique followed by other planning approaches. In medulloblastoma, for posterior fossa and craniospinal irradiation, protons resulted in the least dose to the cochlea (for only posterior fossa irradiation at ≥20 Gy, 34% was the mean cochlear volume irradiated for protons, 87% for IMRT, 89% for 3D-CRT) and hypothalamus-pituitary axis (for only posterior fossa irradiation at ≥10 Gy

  15. Metallic stent and stereotactic conformal radiotherapy for hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Yu; Wang Ning; Tian Qihe; Guo Zhanwen; Zhang Haibo; Song Liyan

    2005-01-01

    Objective: To evaluate the effect of metallic stent combined with stereotactic conformal radiotherapy (SCRT) for hilar cholangiocarcinoma. Methods: Fifty-four patients with hilar cholangiocarcinoma were analyzed, including 31 treated with stent plus stereotactic conformal radiotherapy (combined group) and 23 with metallic stent alone (control group). Results: The mean survival time of combined group was 11.1 ± 4.6 months, compared with 5.1 ± 2.8 months of the control group, giving a significant difference between the two groups (P<0.01). Conclusion: The combination of metallic stent and stereotactic conformal radiotherapy is more effective than metallic stent alone for unresectable hilar cholangiocarcinoma. (authors)

  16. Critical dose and toxicity index of organs at risk in radiotherapy: Analyzing the calculated effects of modified dose fractionation in non–small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pedicini, Piernicola, E-mail: ppiern@libero.it [Service of Medical Physics, I.R.C.C.S. Regional Cancer Hospital C.R.O.B, Rionero in Vulture (Italy); Strigari, Lidia [Laboratory of Medical Physics and Expert Systems, Regina Elena National Cancer Institute, Rome (Italy); Benassi, Marcello [Service of Medical Physics, Scientific Institute of Tumours of Romagna I.R.S.T., Meldola (Italy); Caivano, Rocchina [Service of Medical Physics, I.R.C.C.S. Regional Cancer Hospital C.R.O.B, Rionero in Vulture (Italy); Fiorentino, Alba [U.O. of Radiotherapy, I.R.C.C.S. Regional Cancer Hospital C.R.O.B., Rionero in Vulture (Italy); Nappi, Antonio [U.O. of Nuclear Medicine, I.R.C.C.S. Regional Cancer Hospital C.R.O.B., Rionero in Vulture (Italy); Salvatore, Marco [U.O. of Nuclear Medicine, I.R.C.C.S. SDN Foundation, Naples (Italy); Storto, Giovanni [U.O. of Nuclear Medicine, I.R.C.C.S. Regional Cancer Hospital C.R.O.B., Rionero in Vulture (Italy)

    2014-04-01

    To increase the efficacy of radiotherapy for non–small cell lung cancer (NSCLC), many schemes of dose fractionation were assessed by a new “toxicity index” (I), which allows one to choose the fractionation schedules that produce less toxic treatments. Thirty-two patients affected by non resectable NSCLC were treated by standard 3-dimensional conformal radiotherapy (3DCRT) with a strategy of limited treated volume. Computed tomography datasets were employed to re plan by simultaneous integrated boost intensity-modulated radiotherapy (IMRT). The dose distributions from plans were used to test various schemes of dose fractionation, in 3DCRT as well as in IMRT, by transforming the dose-volume histogram (DVH) into a biological equivalent DVH (BDVH) and by varying the overall treatment time. The BDVHs were obtained through the toxicity index, which was defined for each of the organs at risk (OAR) by a linear quadratic model keeping an equivalent radiobiological effect on the target volume. The less toxic fractionation consisted in a severe/moderate hyper fractionation for the volume including the primary tumor and lymph nodes, followed by a hypofractionation for the reduced volume of the primary tumor. The 3DCRT and IMRT resulted, respectively, in 4.7% and 4.3% of dose sparing for the spinal cord, without significant changes for the combined-lungs toxicity (p < 0.001). Schedules with reduced overall treatment time (accelerated fractionations) led to a 12.5% dose sparing for the spinal cord (7.5% in IMRT), 8.3% dose sparing for V{sub 20} in the combined lungs (5.5% in IMRT), and also significant dose sparing for all the other OARs (p < 0.001). The toxicity index allows to choose fractionation schedules with reduced toxicity for all the OARs and equivalent radiobiological effect for the tumor in 3DCRT, as well as in IMRT, treatments of NSCLC.

  17. Analysis of the efficacy and safety of conventional radiotherapy of chest wall and clavicular field and three-dimensional conformal radiotherapy in patients after modified radical mastectomy

    Directory of Open Access Journals (Sweden)

    Song-Lin Wang

    2017-04-01

    Full Text Available Objective: To explore the efficacy and safety of conventional radiotherapy of chest wall and clavicular field and three-dimensional conformal radiotherapy in patients after modified radical mastectomy. Methods: A total of 84 patients who were admitted in our hospital after modified radical mastectomy were included in the study and divided into the conventional radiotherapy group (n=42 and the three-dimensional conformal radiotherapy group (n=42 according to different radiotherapy methods. The patients in the conventional radiotherapy group were given conventional radiotherapy of chest wall and clavicular field, while the patients in the three-dimensional conformal radiotherapy group were given three-dimensional conformal radiotherapy. The serum tumor markers and peripheral blood T lymphocyte subsets 6-8 weeks after treatment in the two groups were detected. The clinical efficacy, and toxic and side effects in the two groups were evaluated. Results: The serum CA15-3, CA125, CEA, and CK19 levels after treatment in the two groups were significantly reduced when compared with before treatment, CD3 +,CD4 +, and CD4 +/CD8 + were significantly elevated, while CD8 + was significantly reduced when compared with before treatment, but the comparison of the above indicators between the two groups was not statistically significant. The occurrence rate of radioactive skin damage and pneumonia after treatment in the conventional radiotherapy group was significantly higher than that in the three-dimensional conformal radiotherapy group. Conclusions: The two kinds of radiotherapy schemes have an equal efficacy, but the toxic and side effects of three-dimensional conformal radiotherapy are significantly lower than those by the conventional radiotherapy, with a certain advantage.

  18. Three-dimensional conformal radiotherapy with concurrent chemotherapy for postoperative recurrence of esophageal squamous cell carcinoma: clinical efficacy and failure pattern

    International Nuclear Information System (INIS)

    Bao, Yong; Rong, TieHua; Li, Qun; Liu, Hui; Liu, ShiLiang; Zhou, QiChao; Cai, PeiQiang; Anfossi, Simone; Li, QiaoQiao; Hu, YongHong; Liu, MengZhong; Fu, JianHua

    2013-01-01

    To assess the therapeutic outcome and failure pattern of three-dimensional conformal radiotherapy (3D-CRT)-based concurrent chemoradiotherapy (CCRT) for recurrence of esophageal squamous cell carcinoma (SCC) after radical surgery. Treatment outcome and failure pattern were retrospectively evaluated in 83 patients with localized cervical and thoracic recurrences after radical surgery for thoracic esophageal SCC. All patients were treated with 3DCRT-based CCRT (median radiation dose 60 Gy), in which 39 received concurrent cisplatin plus 5-fluorouracil (PF), and 44 received concurrent docetaxel plus cisplatin (TP). Treatment response was evaluated at 1–3 months after CCRT. With a median follow-up of 34 months (range, 2–116 months), the 3-year overall survival (OS) of all the patients was 51.8% and the median OS time was 43.0 months. The overall tumor response rate was 75.9% (63/83), with a complete remission (CR) rate of 44.6% (37/83). In univariate analysis, tumor response after CCRT (p = 0.000), recurrence site (p = 0.028) and concurrent chemotherapy (p = 0.090) showed a trend favoring better OS. Multivariate analysis revealed that tumor response after CCRT (p = 0.000) and concurrent chemotherapy (p = 0.010) were independent predictors of OS. Forty-seven patients had progressive diseases after CCRT, 27 had local failure (27/47, 57.4%), 18 had distant metastasis (18/47, 38.3%) and 2 had both local and distant failures (2/47, 4.3%). 3DCRT-based CCRT is effective in postoperatively recurrent esophageal SCC. Patients that obtained complete remission after CCRT appeared to achieve long-term OS and might benefit from concurrent TP regimen. Local and distant failures remained high and prospective studies are needed to validate these factors

  19. Carotid-Sparing Intensity-Modulated Radiotherapy for Early-Stage Squamous Cell Carcinoma of the True Vocal Cord

    International Nuclear Information System (INIS)

    Chera, Bhishamjit S.; Amdur, Robert J.; Morris, Christopher G.; Mendenhall, William M.

    2010-01-01

    Purpose: To compare radiation doses to carotid arteries among various radiotherapy techniques for treatment of early-stage squamous cell carcinoma (SCC) of the true vocal cords. Methods and Materials: Five patients were simulated using computed tomography (CT). Clinical and planning target volumes (PTV) were created for bilateral and unilateral stage T1 vocal cord cancers. Planning risk volumes for the carotid arteries and spinal cord were delineated. For each patient, three treatment plans were designed for bilateral and unilateral target volumes: opposed laterals (LATS), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT), for a total of 30 plans. More than 95% of the PTV received the prescription dose (63Gy at 2.25 Gy per treatment). Results: Carotid dose was lowest with IMRT. With a bilateral vocal cord target, the median carotid dose was 10Gy with IMRT vs. 25 Gy with 3DCRT and 38 Gy with LATS (p < 0.05); with a unilateral target, the median carotid dose was 4 Gy with IMRT vs. 19 Gy with 3DCRT and 39 Gy with LATS (p < 0.05). The dosimetric tradeoff with IMRT is a small area of high dose in the PTV. The worst heterogeneity results were at a maximum point dose of 80 Gy (127%) in a unilateral target that was close to the carotid. Conclusions: There is no question that IMRT can reduce the dose to the carotid arteries in patients with early-stage vocal cord cancer. The question is whether the potential advantage of reducing the carotid dose outweighs the risk of tumor recurrence due to contouring errors and organ motion and the risk of complications from dose heterogeneity.

  20. Three dimensional conformal postoperative radiotherapy for ...

    African Journals Online (AJOL)

    Azza Helal

    2013-06-17

    Jun 17, 2013 ... during postoperative 3DCRT treatment of parotid gland cancer patients. ... contralateral parotid, oral cavity, cochlea, spinal cord, brain stem, eyes, lenses and ... xerostomia, dry ear, ear infections, hearing deficits and ipsilat-.

  1. Conventional (2D) Versus Conformal (3D) Techniques in Radiotherapy for Malignant Pediatric Tumors: Dosimetric Perspectives

    International Nuclear Information System (INIS)

    Ahmad, N.; Attia, G.; Radwan, A.; El-Badawy, S.; El-Ghoneimy, E.

    2009-01-01

    Objectives: In pediatric radiotherapy, the enhanced radiosensitivity of the developing tissues combined with the high overall survival, raise the possibility of late complications. The present study aims at comparing two dimensional (2D) and three dimensional (3D) planning regarding dose homogeneity within target volume and dose to organs at risk (OARs) to demonstrate the efficacy of 3D in decreasing dose to normal tissue. Material and Methods: Thirty pediatric patients (18 years or less) with different pediatric tumors were planned using 2D and 3D plans. All were CT scanned after proper positioning and immobilization. Structures were contoured; including the planning target volume (PTV) and organs at risk (OARs). Conformal beams were designed and dose distribution analysis was edited to provide the best dose coverage to the PTV while sparing OARs using dose volume histograms (DVHs) of outlined structures. For the same PTVs conventional plans were created using the conventional simulator data (2-4 coplanar fields). Conventional and 3D plans coverage and distribution were compared using the term of V95% (volume of PTV receiving 95% of the prescribed dose), V107% (volume of PTV receiving 107% of the prescribed dose), and conformity index (CI) (volume receiving 90% of the prescribed dose/PTV). Doses received by OARs were compared in terms of mean dose. In children treated for brain lesions, OAR volume received 90% of the dose (V 90%) and OAR score were calculated. Results: The PTV coverage showed no statistical difference between 2D and 3D radiotherapy in terms of V95% or V107%. However, there was more conformity in 3D planning with CI 1.43 rather than conventional planning with CI 1.86 (p-value <0.001). Regarding OARs, 3D planning shows large gain in healthy tissue sparing. There was no statistical difference in mean dose received by each OAR. However, for brain cases, brain stem mean dose and brain V 90% showed better sparing in 3D planning (brain stem mean dose was

  2. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    OpenAIRE

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-01-01

    Introduction Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation ...

  3. On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator.

    Science.gov (United States)

    Putha, Suman Kumar; Saxena, P U; Banerjee, S; Srinivas, Challapalli; Vadhiraja, B M; Ravichandran, Ramamoorthy; Joan, Mary; Pai, K Dinesh

    2016-01-01

    Transmission of radiation fluence through patient's body has a correlation to the planned target dose. A method to estimate the delivered dose to target volumes was standardized using a beam level 0.6 cc ionization chamber (IC) positioned at electronic portal imaging device (EPID) plane from the measured transit signal (S t ) in patients with cancer of uterine cervix treated with three-dimensional conformal radiotherapy (3DCRT). The IC with buildup cap was mounted on linear accelerator EPID frame with fixed source to chamber distance of 146.3 cm, using a locally fabricated mount. S t s were obtained for different water phantom thicknesses and radiation field sizes which were then used to generate a calibration table against calculated midplane doses at isocenter (D iso,TPS ), derived from the treatment planning system. A code was developed using MATLAB software which was used to estimate the in vivo dose at isocenter (D iso,Transit ) from the measured S t s. A locally fabricated pelvic phantom validated the estimations of D iso,Transit before implementing this method on actual patients. On-line dose estimations were made (3 times during treatment for each patient) in 24 patients. The D iso,Transit agreement with D iso,TPS in phantom was within 1.7% and the mean percentage deviation with standard deviation is -1.37% ±2.03% ( n = 72) observed in patients. Estimated in vivo dose at isocenter with this method provides a good agreement with planned ones which can be implemented as part of quality assurance in pelvic sites treated with simple techniques, for example, 3DCRT where there is a need for documentation of planned dose delivery.

  4. Acute morbidity reduction using 3DCRT for prostate carcinoma; a randomised phase III study

    International Nuclear Information System (INIS)

    Koper, P.; Putten, W. van; Stroom, J.; Korevaar, G.; Heijmen, B.; Wijnmaalen, A.; Jansen, P.; Hanssens, P.; Griep, C.; Krol, A.; Samson, M.; Levendag, P.

    1997-01-01

    observed. In the QOL questionnaire analysis complaints were judged to be moderate/severe in resp 30%(conventional) vs 28%(conformal) for intestinal symptoms and 21%(conventional) vs 23% (conformal) for urological symptoms. The expected moderate reduction in exposed volume is diluted by a wide range of anatomical variations. For the bladder a trend for (dose) volume effect is observed. For the rectosigmoid however no relation for toxicity and volume exposed was found. A higher volume exposed is not translated in a increase of toxicity (grade 0 60%, grade I 57% and grade II 57% rectosigmoid volume exposed to doses >90% TD). Conclusions: 1. The randomised phase III study didn't show a statistical significant reduction in acute rectosigmoid and bladder toxicity. The reduction in intestinal morbidity (p=0.02) is mainly caused by reduced anal toxicity for 3DCRT. 2. The CTV-PTV margin of 10 mm will only modestly reduce the volumes exposed. The DVH difference is however further diluted by large anatomical variation. 3. In the preliminary DVH analysis for the first 100 patients a trend for a (dose) volume effect relationship is found for bladder. For rectosigmoid no (dose) volume effect relationship was found. This might be due to the dose level (66 Gy) and the 10 mm CTV-PTV 3D-margins. An extended DVH analysis will be presented

  5. Comparison of intensity-modulated radiotherapy and 3-dimensional conformal radiotherapy as adjuvant therapy for gastric cancer.

    Science.gov (United States)

    Minn, A Yuriko; Hsu, Annie; La, Trang; Kunz, Pamela; Fisher, George A; Ford, James M; Norton, Jeffrey A; Visser, Brendan; Goodman, Karyn A; Koong, Albert C; Chang, Daniel T

    2010-08-15

    The current study was performed to compare the clinical outcomes and toxicity in patients treated with postoperative chemoradiotherapy for gastric cancer using intensity-modulated radiotherapy (IMRT) versus 3-dimensional conformal radiotherapy (3D CRT). Fifty-seven patients with gastric or gastroesophageal junction cancer were treated postoperatively: 26 with 3D CRT and 31 with IMRT. Concurrent chemotherapy was capecitabine (n=31), 5-fluorouracil (5-FU) (n=25), or none (n=1). The median radiation dose was 45 Gy. Dose volume histogram parameters for kidney and liver were compared between treatment groups. The 2-year overall survival rates for 3D CRT versus IMRT were 51% and 65%, respectively (P=.5). Four locoregional failures occurred each in the 3D CRT (15%) and the IMRT (13%) patients. Grade>or=2 acute gastrointestinal toxicity was found to be similar between the 3D CRT and IMRT patients (61.5% vs 61.2%, respectively) but more treatment breaks were needed (3 vs 0, respectively). The median serum creatinine from before radiotherapy to most recent creatinine was unchanged in the IMRT group (0.80 mg/dL) but increased in the 3D CRT group from 0.80 mg/dL to 1.0 mg/dL (P=.02). The median kidney mean dose was higher in the IMRT versus the 3D CRT group (13.9 Gy vs 11.1 Gy; P=.05). The median kidney V20 was lower for the IMRT versus the 3D CRT group (17.5% vs 22%; P=.17). The median liver mean dose for IMRT and 3D CRT was 13.6 Gy and 18.6 Gy, respectively (P=.19). The median liver V30 was 16.1% and 28%, respectively (PCancer Society.

  6. Daily-diary evaluated side-effects of conformal versus conventional prostatic cancer radiotherapy technique

    International Nuclear Information System (INIS)

    Widmark, A.; Fransson, P.; Franzen, L.; Littbrand, B.; Henriksson, R.

    1997-01-01

    Conventional 4-field box radiotherapy technique induces high morbidity for patients with localized prostatic cancer. Using a patient daily diary, the present study compared side-effects after conventional radiotherapy with conformal radiotherapy for prostate cancer. Fifty-eight patients treated with the conventional technique (with or without sucralfate) were compared with 72 patients treated with conformal technique. The patient groups were compared with an age-matched control population. Patients treated with conformal technique were also evaluated regarding acute and late urinary problems. Results showed that patients treated with conformal technique reported significantly fewer side-effects as compared with conventional technique. Patients treated with sucralfate also showed slightly decreased intestinal morbidity in comparison to non-sucralfate group. Acute and late morbidity evaluated by the patients was decreased after conformal radiotherapy as compared with the conventional technique. Sucralfate may be of value if conformal radiotherapy is used for dose escalation in prostatic cancer patients. (orig.)

  7. Conformal radiotherapy using multileaf collimation: quality assurance and in vivo dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Aletti, P [Centre A. Vautrin, Nancy (France)

    1995-12-01

    The application of quality assurance principles in three dimensional conformal therapy is discussed.Critical requirements in three dimensional radiotherapy are the patient immobilization, the location, and the delivered dose. General recommendations with respect to the equipment for conformal radiotherapy and personnel are made.

  8. Conformal radiotherapy using multileaf collimation: quality assurance and in vivo dosimetry

    International Nuclear Information System (INIS)

    Aletti, P.

    1995-01-01

    The application of quality assurance principles in three dimensional conformal therapy is discussed.Critical requirements in three dimensional radiotherapy are the patient immobilization, the location, and the delivered dose. General recommendations with respect to the equipment for conformal radiotherapy and personnel are made

  9. A potential to reduce pulmonary toxicity: The use of perfusion SPECT with IMRT for functional lung avoidance in radiotherapy of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lavrenkov, Konstantin; Christian, Judith A.; Partridge, Mike; Niotsikou, Elena; Cook, Gary; Parker, Michelle; Bedford, James L.; Brada, Michael

    2007-01-01

    Background and purpose: The study aimed to examine specific avoidance of functional lung (FL) defined by a single photon emission computerized tomography (SPECT) lung perfusion scan, using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3-DCRT) in patients with non-small cell lung cancer (NSCLC). Materials and methods: Patients with NSCLC underwent planning computerized tomography (CT) and lung perfusion SPECT scan in the treatment position using fiducial markers to allow co-registration in the treatment planning system. Radiotherapy (RT) volumes were delineated on the CT scan. FL was defined using co-registered SPECT images. Two inverse coplanar RT plans were generated for each patient: 4-field 3-DCRT and 5-field step-and-shoot IMRT. 3-DCRT plans were created using automated AutoPlan optimisation software, and IMRT plans were generated employing Pinnacle 3 treatment planning system (Philips Radiation Oncology Systems). All plans were prescribed to 64 Gy in 32 fractions using data for the 6 MV beam from an Elekta linear accelerator. The objectives for both plans were to minimize the volume of FL irradiated to 20 Gy (fV 20 ) and dose variation within the planning target volume (PTV). A spinal cord dose was constrained to 46 Gy. Volume of PTV receiving 90% of the prescribed dose (PTV 90 ), fV 20 , and functional mean lung dose (fMLD) were recorded. The PTV 90 /fV 20 ratio was used to account for variations in both measures, where a higher value represented a better plan. Results: Thirty-four RT plans of 17 patients with stage I-IIIB NSCLC suitable for radical RT were analysed. In 6 patients with stage I-II disease there was no improvement in PTV 90 , fV 20 , PTV/fV 20 ratio and fMLD using IMRT compared to 3-DCRT. In 11 patients with stage IIIA-B disease, the PTV was equally well covered with IMRT and 3-DCRT plans, with IMRT producing better PTV 90 /fV 20 ratio (mean ratio - 7.2 vs. 5.3, respectively, p = 0.001) and reduced f

  10. Dosimetry comparison of irradiation with conformal radiotherapy, intensity modulated radiotherapy, conformal radiotherapy in stereotactic conditions and robotic stereotactic radiotherapy for benign brain tumours

    International Nuclear Information System (INIS)

    Spasic, E.; Noel, A.; Buchheit, I.; Bernier, V.

    2011-01-01

    Purpose. - To compare several techniques in order to determine the best treatment for benign brain tumours. Methods and patients. - A retrospective study was performed for five patients who received 3D-conformal radiotherapy, intensity modulated radiotherapy or CyberKnife R . These patients had a meningioma, a pituitary tumour, a cranio-pharyngioma or a neurinoma. In each case, these treatment plans were optimised and compared with the three other dosimetries. Radiobiological or positioning parameters were evaluated, as well as dosimetric parameters, in order to compare treatments with different characteristics. Results. - The dosimetric parameters showed that the choice of treatment seemed to be determined mostly by tumour size, shape and proximity with organs at risk (not tumour localisation). Whereas the results showed no significant deviations with regards to the radiobiological parameters. Therefore, with these parameters, it was difficult to give priority to a treatment. Conclusions. - With regards to benign brain tumours of medium or large size, intensity modulated radiotherapy seemed the recommended treatment. It enabled to obtain a good ratio between efficacy and toxicity for tumours that are really close to organs at risk. Concerning small benign brain tumours, the CyberKnife R was probably the best treatment. (authors)

  11. Dose-response relationship in local radiotherapy for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Park, Hee Chul; Seong, Jinsil; Han, Kwang Hyub; Chon, Chae Yoon; Moon, Young Myoung; Suh, Chang Ok

    2002-01-01

    Purpose: Dose escalation using three-dimensional conformal radiotherapy (3D-CRT) is based on the hypothesis that increasing the dose can enhance tumor control. This study aimed to determine whether a dose-response relationship exists in local radiotherapy for primary hepatocellular carcinoma (HCC). Methods and Materials: One hundred fifty-eight patients were enrolled in the present study between January 1992 and March 2000. The exclusion criteria included the presence of an extrahepatic metastasis, liver cirrhosis of Child class C, tumors occupying more than two-thirds of the entire liver, and a performance status on the Eastern Cooperative Oncology Group scale of more than 3. Radiotherapy was given to the field, including the tumor, with generous margin using 6- or 10-MV X-rays. The mean radiation dose was 48.2 ± 7.9 Gy in daily 1.8-Gy fractions. The tumor response was assessed based on diagnostic radiologic examinations, including a computed tomography scan, magnetic resonance imaging, and hepatic artery angiography 4-8 weeks after the completion of treatment. Liver toxicity and gastrointestinal complications were evaluated. Results: An objective response was observed in 106 of 158 (67.1%) patients. Statistical analysis revealed that the total dose was the most significant factor associated with the tumor response. The response rates in patients treated with doses 50 Gy were 29.2%, 68.6%, and 77.1%, respectively. Survivals at 1 and 2 years after radiotherapy were 41.8% and 19.9%, respectively, with a median survival time of 10 months. The rate of liver toxicity according to the doses 50 Gy was 4.2%, 5.9%, and 8.4%, respectively, and the rate of gastrointestinal complications was 4.2%, 9.9%, and 13.2%, respectively. Conclusions: The present study showed the existence of a dose-response relationship in local radiotherapy for primary HCC. Only the radiation dose was a significant factor for predicting an objective response. The results of this study showed that 3D-CRT

  12. Potential risk factors for jaw osteoradionecrosis after radiotherapy for head and neck cancer

    International Nuclear Information System (INIS)

    Kuhnt, Thomas; Stang, Andreas; Wienke, Andreas; Vordermark, Dirk; Schweyen, Ramona; Hey, Jeremias

    2016-01-01

    To identify potential risk factors for the development of jaw osteoradionecrosis (ORN) after 3D-conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) among patients with newly diagnosed head and neck cancer. This study included 776 patients who underwent 3D-CRT or IMRT for head and neck cancer at the Department of Radiotherapy at the University Hospital Halle-Wittenberg between 2003 and 2013. Sex, dental status prior to radiotherapy, tumor site, bone surgery during tumor resection, concomitant chemotherapy, and the development of advanced ORN were documented for each patient. ORN was classified as grade 3, 4, or 5 according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer classification or grade 3 or 4 according to the late effects in normal tissues/subjective, objective, management, and analytic scale. The cumulative incidence of ORN was estimated. Cox regression analysis was used to identify prognostic risk factors for the development of ORN. Fifty-one patients developed advanced ORN (relative frequency 6.6 %, cumulative incidence 12.4 %). The highest risk was found in patients who had undergone primary bone surgery during tumor resection (hazard ratio [HR] = 5.87; 95 % confidence interval [CI]: 3.09–11.19) and in patients with tumors located in the oral cavity (HR = 4.69; 95 % CI: 1.33–16.52). Sex, dentition (dentulous vs. edentulous), and chemotherapy had no clinically relevant influence. In contrast to most previous studies, we noted a low cumulative incidence of advanced ORN. Patients with tumors located in the oral cavity and those who undergo bone surgery during tumor resection prior to RT may be considered a high-risk group for the development of ORN

  13. Conformal radiotherapy for 6 cases of bile duct carcinoma

    International Nuclear Information System (INIS)

    Kawasaki, Yoshiyuki; Suzuki, Takashi; Sugahara, Shinji

    1998-01-01

    Authors performed the conformal radiotherapy using the multileaf collimator for inoperable patients with bile duct carcinoma and examined the usefulness of this treatment. Forty one patients were examined, whose age was from 45 to 80 years (mean: 69.5 years), and whose ratio of men to women was 1 to 1.6. Patients in Group I (palliative irradiation, 30 cases) received bilateral irradiation using the linac with 4 MV-x-ray of total 50.0 Gy (2.0 Gy a dose, 5 times a week), those in Group II (palliative irradiation, 5 cases) using the microtron with 10 MV-x-ray of total 50.0 Gy (2.0 Gy a dose, 5 times a week). And those in Group III (radial irradiation, 6 cases) were first irradiated using the microtron with total 40.0 Gy (2.0 Gy a dose, 5 times a week) and secondly by the conformal radiotherapy with total 20.0 Gy (2.0 Gy a dose, 5 times a week). Patients in Group III were irradiated with total 60.0 Gy. Patients in all Groups showed mild side-effects including nausea and vomiting. And patients in Group III, who were irradiated 10 Gy more than other Group, showed no severe side-effects as alimentary bleeding, liver function disorders and cholangitis. In Group I, one year survivors were 3 (10.0%) and two years survivors were none. The median survival month was 7.2 months. In Group II, one year survivor was 1 (20.0%) and two years survivors were none. The median survival month was 8.1 months. In Group III, one year survivors were 2 (33.3%), and two years survivors were 2 (33.3%). The median survival month was 11.2 months. Two patients are survival at present (March, 1998), 2 years and 10 months, and 2 years and 9 months, respectively. The conformal radiotherapy gave better results than the ordinary radiotherapy. (K.H.)

  14. 三维适形放疗与调强放疗治疗原发性肝癌伴门静脉癌栓的剂量学比较

    Directory of Open Access Journals (Sweden)

    ZHOU Yuanyuan

    2014-03-01

    Full Text Available ObjectiveTo compare three-dimensional conformal radiotherapy (3DCRT and intensity-modulated radiotherapy (IMRT in terms of their advantages of disadvantages in the treatment of primary hepatocellular carcinoma (PHC with portal vein tumor thrombus (PVTT. MethodsTwenty patients with PHC accompanied by PVTT were enrolled in this study. Each patient underwent 3DCRT and IMRT with a prescribed dose of 40 Gy/ 20 fractions. The parameters included the conformity index (CI, homogeneity index (HI, mean dose (Dmean, minimum dose (Dmin, maximum dose (Dmax, V95%, V100%, and V105% for planning target volume (PTV, the number of monitor units (MUs for evaluating planning efficiency, and Dmean, Dmax, and Dmin for the organs at risk (OAR. The percentage of the normal liver volume receiving ≥30, >20, >10, and >5 Gy (V30 Gy, V20 Gy, V10 Gy, and V5 Gy, respectively were calculated to determine liver toxicity. The two radiotherapy regimens were compared in terms of the dosimetric parameters for PTV and OAR, as well as number of MUs. ResultsIMRT had significantly higher Dmin, Dmean, V95%, and V100% and significantly better HI and CI compared with 3DCRT (P<0.05. The liver V30 Gy and V20 Gy were 33.55±5.67 and 44.24±6.17, respectively, for 3DCRT, versus 2941±267 and 41.28±4.59 for IMRT (P=0.001; P=0.021. There were no significant differences in liver V10 Gy, liver V5 Gy, stomach Dmax, small intestine Dmax, spinal cord Dmax, kidney Dmax, and kidney V20 Gy between IMRT and 3DCRT. The number of MUs was 303.7±35.8 for 3DCRT and 377.4±33.2 for IMRT (P=0.000. ConclusionIMRT provides higher tumor coverage, homogeneity, and conformity, as well as better normal liver tissue sparing, as compared with 3DCRT. However, IMRT is not superior to 3DCRT in terms of treatment efficiency.

  15. Clinical Studies on conformal radiotherapy combined with epidermal ...

    African Journals Online (AJOL)

    in second-line treatment of non-small cell lung cancer ... receptor-tyrosine kinase inhibitor (EGFR-TKI) in the second-line treatment of non-small cell ... were divided into two groups: 106 patients were treated with conformal ... Conformal radiotherapy, Targeted therapy, Survival rate .... regression model was used for survival.

  16. Evaluation of homogeneity and dose conformity in IMRT planning in prostate radiotherapy

    International Nuclear Information System (INIS)

    Lopes, Juliane S.; Leidens, Matheus; Estacio, Daniela R.; Razera, Ricardo A.Z.; Streck, Elaine E.; Silva, Ana M.M. da

    2015-01-01

    The goal of this study was to evaluate the dose distribution homogeneity and conformity of radiation therapy plans of prostate cancer using IMRT. Data from 34 treatment plans of Hospital Sao Lucas of PUCRS, where those plans were executed, were retrospectively analyzed. All of them were done with 6MV X-rays from a linear accelerator CLINAC IX, and the prescription doses varied between 60 and 74 Gy. Analyses showing the homogeneity and conformity indices for the dose distribution of those plans were made. During these analyses, some comparisons with the traditional radiation therapy planning technic, the 3D-CRT, were discussed. The results showed that there is no correlation between the prescribed dose and the homogeneity and conformity indices, indicating that IMRT works very well even for higher doses. Furthermore, a comparison between the results obtained and the recommendations of ICRU 83 was carried out. It has also been observed that the indices were really close to the ideal values. 82.4% of the cases showed a difference below 5% of the ideal value for the index of conformity, and 88.2% showed a difference below 10% for the homogeneity index. Concluding, it is possible to confirm the quality of the analyzed radiation therapy plans of prostate cancer using IMRT. (author)

  17. 3DCRT for posterior fossa: Sparing of surrounding organs at risk

    African Journals Online (AJOL)

    Azza Helal

    2013-06-25

    Jun 25, 2013 ... spinal cord, thyroid gland, pharynx, parotid glands and mandible using three different 3DCRT ... Methods: Ten patients underwent CT simulation for treatment .... structures such as the developing brain, bone, thyroid gland,.

  18. Conformal Radiotherapy in the Treatment of Advanced Juvenile Nasopharyngeal Angiofibroma With Intracranial Extension: An Institutional Experience

    International Nuclear Information System (INIS)

    Chakraborty, Santam; Ghoshal, Sushmita; Patil, Vijay Maruti; Oinam, Arun Singh; Sharma, Suresh C.

    2011-01-01

    Purpose: To describe the results of conformal radiotherapy in advanced juvenile nasopharyngeal angiofibroma in a tertiary care institution. Methods and Materials: Retrospective chart review was conducted for 8 patients treated with conformal radiotherapy between 2006 and 2009. The median follow-up was 17 months. All patients had Stage IIIB disease with intracranial extension. Radiotherapy was considered as treatment because patients were deemed inoperable owing to extensive intracranial/intraorbital extension or proximity to optic nerve. All but 1 patient were treated with intensity-modulated radiotherapy using seven coplanar fields. Median (range) dose prescribed was 39.6 (30-46) Gy. Actuarial analysis of local control and descriptive analysis of toxicity profile was conducted. Results: Despite the large and complex target volume (median planning target volume, 292 cm 3 ), intensity-modulated radiotherapy achieved conformal dose distributions (median van't Reit index, 0.66). Significant sparing of the surrounding organs at risk was obtained. No significant Grade 3/4 toxicities were experienced during or after treatment. Actual local control at 2 years was 87.5%. One patient died 1 month after radiotherapy secondary to massive epistaxis. The remaining 7 patients had progressive resolution of disease and were symptom-free at last follow-up. Persistent rhinitis was the only significant toxicity, seen in 1 patient. Conclusions: Conformal radiotherapy results in good local control with minimal acute and late side effects in juvenile nasopharyngeal angiofibromas, even in the presence of advanced disease.

  19. Risk factors of radiation-induced liver disease after three-dimensional conformal radiotherapy for primary liver carcinoma

    International Nuclear Information System (INIS)

    Liang Shixiong; Zhu Xiaodong; Lu Haijie; Pan Chaoyang; Huang Qifang; Li Fuxiang; Wang Anyu; Liang Guoliang; Fu Xiaolong

    2005-01-01

    Objective: To identify the risk factors of radiation-induced liver disease (RILD) after three-dimensional radiotherapy (3DCRT) for primary liver carcinoma (PLC) and the dosimetric threshold of RILD. Methods: Between April 1999 and August 2003, 128 PLC patients who were treated with 3DCRT received a mean dose of 53.6 ± 6.6 Gy with a 4-8 Gy/f, 3f/w, qod regimen. The relation between RILD and the possible clinical factors, such as gender, age, UICC/ AJCC T stage, GTV, HBV status, PTV, TACE, Child-Pugh grade of liver cirrhosis, BED calculated by LQ model and fraction size were analyzed. Among 84 patients who had full dose- volume histogram (DVH) data, the relation between RILD and dosimetric parameters were analyzed. Results: Nineteen patients (14.8%) developed RILD. It was found that T stage, GTV, PTV, Child-Pugh grade of liver cirrhosis and the acute hepatic toxicity proposed by common toxicity criteria version 2.0 (CTC2.0) were correlated with RILD (P=0.024, 0.002, 0.001, 0.000, 0.000, respectively). Multivariate analysis showed that only the Child-Pugh grade of liver cirrhosis was independent factor (P=0.000). The mean liver dose was significantly higher in patients with RILD (P=0.027). In patients with Child-Pugh grade A, V5 (percentage of normal liver volume with radiation dose > 5 Gy), V 10 and V 20 ≤81%, 69% and 42%, mean liver dose ≤28 Gy, RILD was not observed, whereas in patients with Child-Pugh grade B, the possibility of developing RILD was 53.3%(8/15). Conclusions: Comprehensive consideration of T stage, GTV, PTV and Child-Pugh grade of liver cirrhosis, especially the Child-Pugh grade of liver cirrhosis, when planning 3DCRT for PLC, may lower the incidence of RILD. (authors)

  20. 3D-Conformal Versus Intensity-Modulated Postoperative Radiotherapy of Vaginal Vault: A Dosimetric Comparison

    International Nuclear Information System (INIS)

    Cilla, Savino; Macchia, Gabriella; Digesu, Cinzia; Deodato, Francesco; Romanella, Michele; Ferrandina, Gabriella; Padula, Gilbert; Picardi, Vincenzo; Scambia, Giovanni; Piermattei, Angelo; Morganti, Alessio Giuseppe

    2010-01-01

    We evaluated a step-and-shoot IMRT plan in the postoperative irradiation of the vaginal vault compared with equispaced beam arrangements (3-5) 3D-radiotherapy (RT) optimized plans. Twelve patients were included in this analysis. Four plans for each patient were compared in terms of dose-volume histograms, homogeneity index (HI), and conformity index (CI): (1) 3 equispaced beam arrangement 3D-RT; (2) 4 equispaced beam arrangement 3D-RT; (3) 5 equispaced beam arrangement 3D-RT; (4) step-and-shoot IMRT technique. CI showed a good discrimination between the four plans. The mean scores of CI were 0.58 (range: 0.38-0.67) for the 3F-CRT plan, 0.58 (range: 0.41-0.66) for 4F-CRT, 0.62 (range: 0.43-0.68) for 5F-CRT and 0.69 (range: 0.58-0.78) for the IMRT plan. A significant improvement of the conformity was reached by the IMRT plan (p mean , V90%, V95%, V100% was recorded for rectal and bladder irradiation with the IMRT plan. Surprisingly, IMRT supplied a significant dose reduction also for rectum and bladder V30% and V50%. A significant dosimetric advantage of IMRT over 3D-RT in the adjuvant treatment of vaginal vault alone in terms of treatment conformity and rectum and bladder sparing is shown.

  1. Dosimetric and Radiobiologic Comparison of 3D Conformal Versus Intensity Modulated Planning Techniques for Prostate Bed Radiotherapy

    International Nuclear Information System (INIS)

    Koontz, Bridget F.; Das, Shiva; Temple, Kathy; Bynum, Sigrun; Catalano, Suzanne; Koontz, Jason I.; Montana, Gustavo S.; Oleson, James R.

    2009-01-01

    Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

  2. Dosimetric and radiobiologic comparison of 3D conformal versus intensity modulated planning techniques for prostate bed radiotherapy.

    Science.gov (United States)

    Koontz, Bridget F; Das, Shiva; Temple, Kathy; Bynum, Sigrun; Catalano, Suzanne; Koontz, Jason I; Montana, Gustavo S; Oleson, James R

    2009-01-01

    Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

  3. Conformal radiotherapy: a glossary

    International Nuclear Information System (INIS)

    Dubray, B.; Giraud, P.; Beaudre, A.

    1999-01-01

    Most of the concepts and terms related to conformal radiotherapy were produced by English-speaking authors and eventually validated by international groups of experts, whose working language was also English. Therefore, a significant part of this literature is poorly accessible to the French-speaking radiation oncology community. The present paper gathers the 'official' definitions already published in French, along with propositions for the remaining terms which should be submitted to a more formal and representative validation process. (author)

  4. Effective avoidance of a functional spect-perfused lung using intensity modulated radiotherapy (IMRT) for non-small cell lung cancer (NSCLC): An update of a planning study

    International Nuclear Information System (INIS)

    Lavrenkov, Konstantin; Singh, Shalini; Christian, Judith A.; Partridge, Mike; Nioutsikou, Elena; Cook, Gary; Bedford, James L.; Brada, Michael

    2009-01-01

    IMRT and 3-dimensional conformal radiotherapy (3-DCRT) plans of 25 patients with non-small cell lung (NSCLC) were compared in terms of planning target volume (PTV) coverage and sparing of functional lung (FL) defined by a SPECT perfusion scan. IMRT resulted in significant reduction of functional V 20 and mean lung dose in stage III patients with inhomogeneous hypoperfusion. If the dose to FL is shown to be the determinant of lung toxicity, IMRT would allow for effective dose escalation by specific avoidance of functional lung.

  5. Extracranial stereotactic radiotherapy: Evaluation of PTV coverage and dose conformity

    International Nuclear Information System (INIS)

    Haedinger, U.; Thiele, W.; Wulf, J.

    2002-01-01

    During the past few years the concept of cranial sterotactic radiotherapy has been successfully extended to extracranial tumoral targets. In our department, hypofractionated treatment of tumours in lung, liver, abdomen, and pelvis is performed in the Stereotactic Body Frame (ELEKTA Instrument AB) since 1997. We present the evaluation of 63 consecutively treated targets (22 lung, 21 liver, 20 abdomen/pelvis) in 58 patients with respect to dose coverage of the planning target volume (PTV) as well as conformity of the dose distribution. The mean PTV coverage was found to be 96.3%±2.3% (lung), 95.0%±4.5% (liver), and 92.1%±5.2% (abdomen/pelvis). For the so-called conformation number we obtained values of 0.73±0.09 (lung), 0.77±0.10 (liver), and 0.70±0.08 (abdomen/pelvis). The results show that highly conformal treatment techniques can be applied also in extracranial stereotactic radiotherapy. This is primarily due to the relatively simple geometrical shape of most of the targets. Especially lung and liver targets turned out to be approximately spherically/cylindrically shaped, so that the dose distribution can be easily tailored by rotational fields. (orig.) [de

  6. Comparison and Limitations of DVH-Based NTCP Models Derived From 3D-CRT and IMRT Data for Prediction of Gastrointestinal Toxicities in Prostate Cancer Patients by Using Propensity Score Matched Pair Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Troeller, Almut [Department of Radiation Oncology, William Beaumont Health System, Royal Oak, Michigan (United States); Department of Radiotherapy and Radiation Oncology, Ludwig-Maximilians-Universität, Munich (Germany); Yan, Di, E-mail: dyan@beaumont.edu [Department of Radiation Oncology, William Beaumont Health System, Royal Oak, Michigan (United States); Marina, Ovidiu; Schulze, Derek [Department of Radiation Oncology, William Beaumont Health System, Royal Oak, Michigan (United States); Alber, Markus [Department of Oncology, Aarhus University Hospital, Aarhus (Denmark); Parodi, Katia [Department of Medical Physics, Ludwig-Maximilians-Universität, Munich (Germany); Belka, Claus; Söhn, Matthias [Department of Radiotherapy and Radiation Oncology, Ludwig-Maximilians-Universität, Munich (Germany)

    2015-02-01

    Purpose: This study compared normal tissue complication probability (NTCP) modeling of chronic gastrointestinal toxicities following prostate cancer treatment for 2 treatment modalities. Possible factors causing discrepancies in optimal NTCP model parameters between 3-dimensional conformal radiation therapy (3D-CRT) and intensity modulated RT (IMRT) were analyzed and discussed, including the impact of patient characteristics, image guidance, toxicity scoring bias, and NTCP model limitations. Methods and Materials: Rectal wall dose-volume histograms of 1115 patients treated for prostate cancer under an adaptive radiation therapy protocol were used to model gastrointestinal toxicity grade ≥2 (according to Common Terminology Criteria for Adverse Events). A total of 457 patients were treated with 3D-CRT and 658 with IMRT. 3D-CRT patients were matched to IMRT patients based on various patient characteristics, using a propensity score–based algorithm. Parameters of the Lyman equivalent uniform dose and cut-off dose logistic regression NTCP models were estimated for the 2 matched treatment modalities and the combined group. Results: After they were matched, the 3D-CRT and IMRT groups contained 275 and 550 patients with a large discrepancy of 28.7% versus 7.8% toxicities, respectively (P<.001). For both NTCP models, optimal parameters found for the 3D-CRT groups did not fit the IMRT patients well and vice versa. Models developed for the combined data overestimated NTCP for the IMRT patients and underestimated NTCP for the 3D-CRT group. Conclusions: Our analysis did not reveal a single definitive cause for discrepancies of model parameters between 3D-CRT and IMRT. Patient characteristics and bias in toxicity scoring, as well as image guidance alone, are unlikely causes of the large discrepancy of toxicities. Whether the cause was inherent to the specific NTCP models used in this study needs to be verified by future investigations. Because IMRT is increasingly used

  7. Salvage conformal radiotherapy for biochemical recurrent prostate cancer after radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Carlos R. Monti

    2006-08-01

    Full Text Available OBJECTIVE: Assess the results of salvage conformal radiotherapy in patients with biochemical failure after radical prostatectomy and identify prognostic factors for biochemical recurrence and toxicity of the treatment. MATERIALS AND METHODS: From June 1998 to November 2001, 35 patients were submitted to conformal radiotherapy for PSA > 0.2 ng/mL in progression after radical prostatectomy and were retrospectively analyzed. The mean dose of radiation in prostatic bed was of 77.4 Gy (68-81. Variables related to the treatment and to tumor were assessed to identify prognostic factors for biochemical recurrence after salvage radiotherapy. RESULTS: The median follow-up was of 55 months (17-83. The actuarial survival rates free of biochemical recurrence and free of metastasis at a distance of 5 years were 79.7% e 84.7%, respectively. The actuarial global survival rate in 5 years was 96.1%.The actuarial survival rate free of biochemical recurrence in 5 years was 83.3% with PSA pre-radiotherapy 1 and 2 (p = 0.023. Dose > 70 Gy in 30% of the bladder volume implied in more acute urinary toxicity (p = 0.035. The mean time for the development of late urinary toxicity was 21 months (12-51. Dose > 55 Gy in 50% bladder volume implied in more late urinary toxicity (p = 0.018. A patient presented late rectal toxicity of 2nd grade. CONCLUSIONS: Conformal radiotherapy showed to be effective for the control of biochemical recurrence after radical prostatectomy. Patients with pre-therapy PSA < 2 ng/mL have more biochemical control.

  8. Choosing wisely after publication of level I evidence in breast cancer radiotherapy.

    Science.gov (United States)

    Niska, Joshua R; Keole, Sameer R; Pockaj, Barbara A; Halyard, Michele Y; Patel, Samir H; Northfelt, Donald W; Gray, Richard J; Wasif, Nabil; Vargas, Carlos E; Wong, William W

    2018-01-01

    Recent trials in early-stage breast cancer support hypofractionated whole-breast radiotherapy (WBRT) as part of breast-conserving therapy (BCT). Evidence also suggests that radiotherapy (RT) omission may be reasonable for some patients over 70 years. Among radiation-delivery techniques, intensity-modulated RT (IMRT) is more expensive than 3-dimensional conformal RT (3DCRT). Based on this evidence, in 2013, the American Society for Radiation Oncology (ASTRO) recommended hypofractionated schedules for women aged ≥50 years with early-stage breast cancer and avoiding routine use of IMRT for WBRT. To assess response to level I evidence and adherence to ASTRO recommendations, we evaluated the pattern of RT use for early-stage breast cancer at our National Comprehensive Cancer Network institution from 2006 to 2008 and 2011 to 2013 and compared the results with national trends. Data from a prospective database were extracted to include patients treated with BCT, aged ≥50 years, with histologic findings of invasive ductal carcinoma, stage T1-T2N0M0, estrogen receptor-positive, and HER2 normal. We retrospectively reviewed the medical records and estimated costs based on 2016 Hospital Outpatient Prospective Payment System (technical fees) and Medicare Physician Fee Schedule (professional fees). Among 55 cases from 2006 to 2008, treatment regimens were 11% hypofractionated, 69% traditional schedule, and 20% RT omission (29% of patients were aged >70 years). Among 83 cases from 2011 to 2013, treatment regimens were 54% hypofractionated, 19% traditional schedule, and 27% RT omission (48% of patients were aged >70 years). 3DCRT was used for all WBRT treatments. Direct medical cost estimates were as follows: 15 fractions 3DCRT, $7,197.87; 15 fractions IMRT, $11,232.33; 25 fractions 3DCRT, $9,731.39; and 25 fractions IMRT, $16,877.45. Despite apparent resistance to shorter radiation schedules in the United States, we demonstrate that rapid practice change in response to level I

  9. A planning comparison of 7 irradiation options allowed in RTOG 1005 for early-stage breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Guang-Pei, E-mail: gpchen@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Liu, Feng [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); White, Julia [Department of Radiation Oncology, The Ohio State University, Columbus, OH (United States); Vicini, Frank A. [Michigan Healthcare Professionals/21st Century Oncology, Farmington Hills, MI (United States); Freedman, Gary M. [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Arthur, Douglas W. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA (United States); Li, X. Allen [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States)

    2015-04-01

    This study compared the 7 treatment plan options in achieving the dose-volume criteria required by the Radiation Therapy Oncology Group (RTOG) 1005 protocol. Dosimetry plans were generated for 15 representative patients with early-stage breast cancer (ESBC) based on the protocol-required dose-volume criteria for each of the following 7 treatment options: 3D conformal radiotherapy (3DCRT), whole-breast irradiation (WBI) plus 3DCRT lumpectomy boost, 3DCRT WBI plus electron boost, 3DCRT WBI plus intensity-modulated radiation therapy (IMRT) boost, IMRT WBI plus 3DCRT boost, IMRT WBI plus electron boost, IMRT WBI plus IMRT boost, and simultaneous integrated boost (SIB) with IMRT. A variety of dose-volume parameters, including target dose conformity and uniformity and normal tissue sparing, were compared for these plans. For the patients studied, all plans met the required acceptable dose-volume criteria, with most of them meeting the ideal criteria. When averaged over patients, most dose-volume goals for all plan options can be achieved with a positive gap of at least a few tenths of standard deviations. The plans for all 7 options are generally comparable. The dose-volume goals required by the protocol can in general be easily achieved. IMRT WBI provides better whole-breast dose uniformity than 3DCRT WBI does, but it causes no significant difference for the dose conformity. All plan options are comparable for lumpectomy dose uniformity and conformity. Patient anatomy is always an important factor when whole-breast dose uniformity and conformity and lumpectomy dose conformity are considered.

  10. Volumetric modulated arc radiotherapy for esophageal cancer

    International Nuclear Information System (INIS)

    Vivekanandan, Nagarajan; Sriram, Padmanaban; Syam Kumar, S.A.; Bhuvaneswari, Narayanan; Saranya, Kamalakannan

    2012-01-01

    A treatment planning study was performed to evaluate the performance of volumetric arc modulation with RapidArc (RA) against 3D conformal radiation therapy (3D-CRT) and conventional intensity-modulated radiation therapy (IMRT) techniques for esophageal cancer. Computed tomgraphy scans of 10 patients were included in the study. 3D-CRT, 4-field IMRT, and single-arc and double-arc RA plans were generated with the aim to spare organs at risk (OAR) and healthy tissue while enforcing highly conformal target coverage. The planning objective was to deliver 54 Gy to the planning target volume (PTV) in 30 fractions. Plans were evaluated based on target conformity and dose-volume histograms of organs at risk (lung, spinal cord, and heart). The monitor unit (MU) and treatment delivery time were also evaluated to measure the treatment efficiency. The IMRT plan improves target conformity and spares OAR when compared with 3D-CRT. Target conformity improved with RA plans compared with IMRT. The mean lung dose was similar in all techniques. However, RA plans showed a reduction in the volume of the lung irradiated at V 20Gy and V 30Gy dose levels (range, 4.62–17.98%) compared with IMRT plans. The mean dose and D 35% of heart for the RA plans were better than the IMRT by 0.5–5.8%. Mean V 10Gy and integral dose to healthy tissue were almost similar in all techniques. But RA plans resulted in a reduced low-level dose bath (15–20 Gy) in the range of 14–16% compared with IMRT plans. The average MU needed to deliver the prescribed dose by RA technique was reduced by 20–25% compared with IMRT technique. The preliminary study on RA for esophageal cancers showed improvements in sparing OAR and healthy tissue with reduced beam-on time, whereas only double-arc RA offered improved target coverage compared with IMRT and 3D-CRT plans.

  11. Intensity-modulated radiotherapy prolongs the survival of patients with nasopharyngeal carcinoma compared with conventional two-dimensional radiotherapy: A 10-year experience with a large cohort and long follow-up.

    Science.gov (United States)

    Zhang, Meng-Xia; Li, Jing; Shen, Guo-Ping; Zou, Xiong; Xu, Jun-Jie; Jiang, Rou; You, Rui; Hua, Yi-Jun; Sun, Ying; Ma, Jun; Hong, Ming-Huang; Chen, Ming-Yuan

    2015-11-01

    To evaluate the survival benefit of intensity-modulated radiotherapy (IMRT) compared with conventional two-dimensional radiotherapy (2D-CRT) in nasopharyngeal carcinoma (NPC) using a large cohort with long follow-up. We retrospectively analysed 7081 non-metastatic NPC patients who received curative IMRT or 2D-CRT from February 2002 to December 2011. Of the 7081 patients, 2245 (31.7%) were administered IMRT, while 4836 (68.3%) were administered 2D-CRT. At 5 years, the patients administered IMRT had significantly higher local relapse-free survival (LRFS), loco-regional relapse-free survival (LRRFS), progression-free survival (PFS) and overall survival (OS) (95.6%, 92.5%, 82.1% and 87.4%, respectively) than those administered 2D-CRT (90.8%, 88.5%, 76.7% and 84.5%, respectively; p<0.001). The distant metastasis-free survival (DMFS) was higher for IMRT than 2D-CRT, with borderline significance (87.6% and 85.7%, respectively; p=0.056). However, no difference was observed between IMRT and 2D-CRT in nodal relapse-free survival (NRFS; 96.3% and 97.4%, respectively; p=0.217). Multivariate analyses showed that IMRT was an independent protective prognostic factor for LRFS, LRRFS and PFS, but not NRFS, DMFS or OS. IMRT provided an improved LRFS, LRRFS and PFS in both the early and advanced T classifications and overall stage for non-disseminated NPC compared with 2D-CRT. However, no significant advantage was observed in NRFS, DMFS or OS when IMRT was used. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Left-sided breast cancer and risks of secondary lung cancer and ischemic heart disease. Effects of modern radiotherapy techniques

    Energy Technology Data Exchange (ETDEWEB)

    Corradini, Stefanie; Ballhausen, Hendrik; Weingandt, Helmut; Freislederer, Philipp; Schoenecker, Stephan; Niyazi, Maximilian; Belka, Claus [University Hospital, LMU Munich, Department of Radiation Oncology, Munich (Germany); Simonetto, Cristoforo; Eidemueller, Markus [Helmholtz Zentrum Muenchen, Institute of Radiation Protection, Neuherberg (Germany); Ganswindt, Ute [University Hospital, LMU Munich, Department of Radiation Oncology, Munich (Germany); Medical University, Department of Radiation Oncology, Innsbruck (Austria)

    2018-03-15

    Modern breast cancer radiotherapy techniques, such as respiratory-gated radiotherapy in deep-inspiration breath-hold (DIBH) or volumetric-modulated arc radiotherapy (VMAT) have been shown to reduce the high dose exposure of the heart in left-sided breast cancer. The aim of the present study was to comparatively estimate the excess relative and absolute risks of radiation-induced secondary lung cancer and ischemic heart disease for different modern radiotherapy techniques. Four different treatment plans were generated for ten computed tomography data sets of patients with left-sided breast cancer, using either three-dimensional conformal radiotherapy (3D-CRT) or VMAT, in free-breathing (FB) or DIBH. Dose-volume histograms were used for organ equivalent dose (OED) calculations using linear, linear-exponential, and plateau models for the lung. A linear model was applied to estimate the long-term risk of ischemic heart disease as motivated by epidemiologic data. Excess relative risk (ERR) and 10-year excess absolute risk (EAR) for radiation-induced secondary lung cancer and ischemic heart disease were estimated for different representative baseline risks. The DIBH maneuver resulted in a significant reduction of the ERR and estimated 10-year excess absolute risk for major coronary events compared to FB in 3D-CRT plans (p = 0.04). In VMAT plans, the mean predicted risk reduction through DIBH was less pronounced and not statistically significant (p = 0.44). The risk of radiation-induced secondary lung cancer was mainly influenced by the radiotherapy technique, with no beneficial effect through DIBH. VMAT plans correlated with an increase in 10-year EAR for radiation-induced lung cancer as compared to 3D-CRT plans (DIBH p = 0.007; FB p = 0.005, respectively). However, the EARs were affected more strongly by nonradiation-associated risk factors, such as smoking, as compared to the choice of treatment technique. The results indicate that 3D-CRT plans in DIBH pose the lowest

  13. Does hormonal therapy influence sexual function in men receiving 3D conformal radiation therapy for prostate cancer?

    International Nuclear Information System (INIS)

    Chen, Christopher T.; Valicenti, Richard K.; Lu Jiandong; Derose, Troy; Dicker, Adam P.; Strup, Stephen E.; Mulholland, S. Grant; Hirsch, Irvin H.; McGinnis, David E.; Gomella, Leonard G.

    2001-01-01

    Purpose: We evaluated the effect of three-dimensional conformal radiation therapy (3D-CRT) with or without hormonal therapy (HT) on sexual function (SF) in prostate cancer patients whose SF was known before all treatment. Methods and Materials: Between March 1996 and March 1999, 144 patients received 3D-CRT (median dose = 70.2 Gy, range 66.6-79.2 Gy) for prostate cancer and had pre- and post-therapy SF data. All SF data were obtained with the O'Leary Brief SF Inventory, a self-administered, multidimensional, validated instrument. We defined total sexual potency as erections firm enough for penetration during intercourse. Mean follow-up time was 21 months (SD ± 11 months). The Wilcoxon signed-rank test was used to test for significance of the change from baseline. Results: Before 3D-CRT, 87 (60%) of 144 men were totally potent as compared to only 47 (47%) of 101 at 1-year follow-up. Of the 60 men totally potent at baseline and followed for at least 1 year, 35 (58%) remained totally potent. These changes corresponded to a significant reduction in SF (p<0.05). Patients who had 3D-CRT alone were more likely to be totally potent at 1 year than those receiving 3D-CRT with HT (56% vs. 31%, p=0.012); however, they were also more likely to be potent at baseline (71% vs. 44%, p=0.001). Although these two groups had a significant reduction in SF from baseline, their change was not significantly different from each other. Conclusion: These data indicate that 3D-CRT causes a significant reduction in total sexual potency as compared to pretreatment baseline. The addition of HT does not appear to increase the risk of sexual dysfunction

  14. Prone Whole-Breast Irradiation Using Three-Dimensional Conformal Radiotherapy in Women Undergoing Breast Conservation for Early Disease Yields High Rates of Excellent to Good Cosmetic Outcomes in Patients With Large and/or Pendulous Breasts

    Energy Technology Data Exchange (ETDEWEB)

    Bergom, Carmen; Kelly, Tracy; Morrow, Natalya; Wilson, J. Frank [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Walker, Alonzo [Department of Surgery, Medical College of Wisconsin, Milwaukee, WI (United States); Xiang Qun; Ahn, Kwang Woo [Division of Biostatistics, Medical College of Wisconsin, Milwaukee, WI (United States); White, Julia, E-mail: jwhite@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States)

    2012-07-01

    Purpose: To report our institution's experience using prone positioning for three-dimensional conformal radiotherapy (3D-CRT) to deliver post-lumpectomy whole breast irradiation (WBI) in a cohort of women with large and/or pendulous breasts, to determine the rate of acute and late toxicities and, more specifically, cosmetic outcomes. We hypothesized that using 3D-CRT for WBI in the prone position would reduce or eliminate patient and breast size as negative prognostic indicators for toxicities associated with WBI. Methods and Materials: From 1998 to 2006, 110 cases were treated with prone WBI using 3D-CRT. The lumpectomy, breast target volumes, heart, and lung were contoured on all computed tomography scans. A dose of 45-50 Gy was prescribed to the breast volume using standard fractionation schemes. The planning goals were {>=}95% of prescription to 95% of the breast volume, and 100% of boost dose to 95% of lumpectomy planning target volume. Toxicities and cosmesis were prospectively scored using the Common Terminology Criteria for Adverse Effects Version 3.0 and the Harvard Scale. The median follow-up was 40 months. Results: The median body mass index (BMI) was 33.6 kg/m{sup 2}, and median breast volume was 1396 cm{sup 3}. The worst toxicity encountered during radiation was Grade 3 dermatitis in 5% of our patient population. Moist desquamation occurred in 16% of patients, with only 2% of patients with moist desquamation outside the inframammary/axillary folds. Eleven percent of patients had Grade {>=}2 late toxicities, including Grade 3 induration/fibrosis in 2%. Excellent to good cosmesis was achieved in 89%. Higher BMI was associated with moist desquamation and breast pain, but BMI and breast volume did not impact fibrosis or excellent to good cosmesis. Conclusion: In patients with higher BMI and/or large-pendulous breasts, delivering prone WBI using 3D-CRT results in favorable toxicity profiles and high excellent to good cosmesis rates. Higher BMI was

  15. Dosimetric impact of inter-observer variability for 3D conformal radiotherapy and volumetric modulated arc therapy: the rectal tumor target definition case

    International Nuclear Information System (INIS)

    Lobefalo, Francesca; Cozzi, Luca; Scorsetti, Marta; Mancosu, Pietro; Bignardi, Mario; Reggiori, Giacomo; Tozzi, Angelo; Tomatis, Stefano; Alongi, Filippo; Fogliata, Antonella; Gaudino, Anna; Navarria, Piera

    2013-01-01

    To assess the dosimetric effect induced by inter-observer variability in target definition for 3D-conformal RT (3DCRT) and volumetric modulated arc therapy by RapidArc (RA) techniques for rectal cancer treatment. Ten patients with rectal cancer subjected to neo-adjuvant RT were randomly selected from the internal database. Four radiation oncologists independently contoured the clinical target volume (CTV) in blind mode. Planning target volume (PTV) was defined as CTV + 7 mm in the three directions. Afterwards, shared guidelines between radiation oncologists were introduced to give general criteria for the contouring of rectal target and the four radiation oncologists defined new CTV following the guidelines. For each patient, six intersections (I) and unions (U) volumes were calculated coupling the contours of the various oncologists. This was repeated for the contours drawn after the guidelines. Agreement Index (AI = I/U) was calculated pre and post guidelines. Two RT plans (one with 3DCRT technique using 3–4 fields and one with RA using a single modulated arc) were optimized on each radiation oncologist’s PTV. For each plan the PTV volume receiving at least 95% of the prescribed dose (PTV V95%) was calculated for both target and non-target PTVs. The inter-operator AI pre-guidelines was 0.57 and was increased up to 0.69 post-guidelines. The maximum volume difference between the various CTV couples, drawn for each patient, passed from 380 ± 147 cm 3 to 137 ± 83 cm 3 after the introduction of guidelines. The mean percentage for the non-target PTV V95% was 93.7 ± 9.2% before and 96.6 ± 4.9%after the introduction of guidelines for the 3DCRT, for RA the increase was more relevant, passing from 86.5 ± 13.8% (pre) to 94.5 ± 7.5% (post). The OARs were maximally spared with VMAT technique while the variability between pre and post guidelines was not relevant in both techniques. The contouring inter-observer variability has dosimetric effects in the PTV coverage

  16. Nasopharyngeal Carcinoma Treated with Precision-Oriented Radiation Therapy Techniques Including Intensity-Modulated Radiotherapy: Preliminary Results

    Directory of Open Access Journals (Sweden)

    Wen-Shan Liu

    2004-02-01

    Full Text Available This paper reports preliminary results with intensity-modulated radiotherapy (IMRT in nasopharyngeal carcinoma (NPC. Between August 2000 and May 2001, we treated 19 patients with NPC using IMRT. Twelve patients had stage I-II disease and seven had stage III-IV disease. Six patients received 9.0-19.8 Gy three-dimensional conformal radiotherapy (3D-CRT before IMRT and 18 patients received a brachytherapy boost after IMRT. The mean follow-up time was 13.0 months. All patients with stage II-IV disease except one received two cycles of chemoradiotherapy with cisplatin and 5-fluorouracil (5-FU during radiotherapy, followed by two to four cycles of chemotherapy after radiotherapy. Tumor response was assessed using clinical examination and computerized tomography or magnetic resonance imaging. The mean doses administered to the gross tumor volume and clinical tumor volume were 70.9 Gy and 63.2 Gy, respectively. The mean doses administered to the right and left parotid glands were 38.1 Gy and 38.6 Gy, respectively. All 19 patients had a complete response of primary and lymph node disease. Grade III mucositis developed during chemoradiotherapy in 15 patients (79%. In addition, clinical grade I xerostomia was recorded in nine patients, grade II in nine, and grade III in one. This study demonstrated that 3D-CRT, IMRT, intracavitary brachytherapy, and chemotherapy are effective and safe methods to treat NPC. Although IMRT treatment spared parotid gland function, its efficacy may be significantly influenced by disease stage and location of the neck lymph nodes. More cases and a longer follow-up to assess survival and complications are planned.

  17. Limited Advantages of Intensity-Modulated Radiotherapy Over 3D Conformal Radiation Therapy in the Adjuvant Management of Gastric Cancer

    International Nuclear Information System (INIS)

    Alani, Shlomo; Soyfer, Viacheslav; Strauss, Natan; Schifter, Dan; Corn, Benjamin W.

    2009-01-01

    Purpose: Although chemoradiotherapy was considered the standard adjuvant treatment for gastric cancer, a recent Phase III trial (Medical Research Council Adjuvant Gastric Infusional Chemotherapy [MAGIC]) did not include radiotherapy in the randomization scheme because it was considered expendable. Given radiotherapy's potential, efforts needed to be made to optimize its use for treating gastric cancer. We assessed whether intensity-modulated radiotherapy (IMRT) could improve upon our published results in patients treated with three-dimensional (3D) conformal therapy. Methods and Materials: Fourteen patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a noncoplanar four-field arrangement. Subsequently, a nine-field IMRT plan was designed using a CMS Xio IMRT version 4.3.3 module. Two IMRT beam arrangements were evaluated: beam arrangement 1 consisted of gantry angles of 0 deg., 53 deg., 107 deg., 158 deg., 204 deg., 255 deg., and 306 deg.. Beam arrangement 2 consisted of gantry angles of 30 deg., 90 deg., 315 deg., and 345 deg.; a gantry angle of 320 deg./couch, 30 deg.; and a gantry angle of 35 o /couch, 312 o . Both the target volume coverage and the dose deposition in adjacent critical organs were assessed in the plans. Dose-volume histograms were generated for the clinical target volume, kidneys, spine, and liver. Results: Comparison of the clinical target volumes revealed satisfactory coverage by the 95% isodose envelope using either IMRT or 3D conformal therapy. However, IMRT was only marginally better than 3D conformal therapy at protecting the spine and kidneys from radiation. Conclusions: IMRT confers only a marginal benefit in the adjuvant treatment of gastric cancer and should be used only in the small subset of patients with risk factors for kidney disease or those with a preexisting nephropathy.

  18. Limited advantages of intensity-modulated radiotherapy over 3D conformal radiation therapy in the adjuvant management of gastric cancer.

    Science.gov (United States)

    Alani, Shlomo; Soyfer, Viacheslav; Strauss, Natan; Schifter, Dan; Corn, Benjamin W

    2009-06-01

    Although chemoradiotherapy was considered the standard adjuvant treatment for gastric cancer, a recent Phase III trial (Medical Research Council Adjuvant Gastric Infusional Chemotherapy [MAGIC]) did not include radiotherapy in the randomization scheme because it was considered expendable. Given radiotherapy's potential, efforts needed to be made to optimize its use for treating gastric cancer. We assessed whether intensity-modulated radiotherapy (IMRT) could improve upon our published results in patients treated with three-dimensional (3D) conformal therapy. Fourteen patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a noncoplanar four-field arrangement. Subsequently, a nine-field IMRT plan was designed using a CMS Xio IMRT version 4.3.3 module. Two IMRT beam arrangements were evaluated: beam arrangement 1 consisted of gantry angles of 0 degrees , 53 degrees , 107 degrees , 158 degrees , 204 degrees , 255 degrees , and 306 degrees . Beam arrangement 2 consisted of gantry angles of 30 degrees , 90 degrees , 315 degrees , and 345 degrees ; a gantry angle of 320 degrees /couch, 30 degrees ; and a gantry angle of 35 degrees /couch, 312 degrees . Both the target volume coverage and the dose deposition in adjacent critical organs were assessed in the plans. Dose-volume histograms were generated for the clinical target volume, kidneys, spine, and liver. Comparison of the clinical target volumes revealed satisfactory coverage by the 95% isodose envelope using either IMRT or 3D conformal therapy. However, IMRT was only marginally better than 3D conformal therapy at protecting the spine and kidneys from radiation. IMRT confers only a marginal benefit in the adjuvant treatment of gastric cancer and should be used only in the small subset of patients with risk factors for kidney disease or those with a preexisting nephropathy.

  19. SU-F-T-646: SBRT Lung: Moving Beyond the 3D Conformal Paradigm with An Elekta VersaHD Accelerator

    International Nuclear Information System (INIS)

    Dalhart, A; Hyer, D; Allen, B; Flynn, R; Johnston, H

    2016-01-01

    Purpose: To develop a volumetric modulated arc therapy (VMAT) planning and delivery methodology for lung stereotactic body radiation therapy (SBRT) that addresses the unique geometric challenges presented when using an Elekta VersaHD linear accelerator. Methods: The Elekta VersaHD imaging panels are fixed at 160cm SID when deployed, limiting the ability to perform non-coplanar treatments due to collisions with the treatment table. The panels can be folded in a stored position for non-coplanar treatments, but in this configuration, longitudinal table travel is restricted by the space required for the folded panels. To overcome these design features, a non-coplanar VMAT technique was designed and evaluated for 6 patients that uses a superiorly placed isocenter near the apex of the lung. A coplanar VMAT technique with isocenter placement within the target was also assessed for each patient. Non-coplanar plans included three arcs, totalling 340° of arc angle, while coplanar plans included two arcs, totalling 280° of arc angle. Each technique avoided the contralateral lung and major overlap on patient skin. Corresponding 3DCRT plans were used as a baseline for each patient in evaluating VMAT plans. Results: Coplanar and noncoplanar VMAT plans yielded a high dose conformity index (CI) improvement of 6% and low dose CI improvements of 9% and 11%, respectively, over corresponding 3DCRT plans. While both VMAT techniques provided greater skin sparing compared to 3DCRT, the non-coplanar technique offered an improvement of 20% over the coplanar approach. Treatment time with for VMAT was ∼2.5 minutes compared to ∼10 minutes for 3DCRT. Conclusion: Two VMAT techniques were developed for lung SBRT that account for machine design limitations and provide greater dose conformity and normal tissue sparing than 3DCRT plans. The non-coplanar VMAT plans showed a marginal improvement over coplanar VMAT plans and may not warrant the additional complexity.

  20. Salvage conformal radiotherapy for biochemical recurrent prostate cancer after radical prostatectomy

    International Nuclear Information System (INIS)

    Monti, Carlos R.; Nakamura, Ricardo A.; Ferrigno, Robson; Rossi Junior, Aristides; Kawakami, Neusa S.; Trevisan, Felipe A.

    2006-01-01

    Objective: Assess the results of salvage conformal radiotherapy in patients with biochemical failure after radical prostatectomy and identify prognostic factors for biochemical recurrence and toxicity of the treatment. Materials and methods: From June 1998 to November 2001, 35 patients were submitted to conformal radiotherapy for PSA ≥ 0.2 ng/mL in progression after radical prostatectomy and were retrospectively analyzed. The mean dose of radiation in prostatic bed was of 77.4 Gy (68-81). Variables related to the treatment and to tumor were assessed to identify prognostic factors for biochemical recurrence after salvage radiotherapy. Results: The median follow-up was of 55 months (17-83). The actuarial survival rates free of biochemical recurrence and free of metastasis at a distance of 5 years were 79.7% e 84.7%, respectively. The actuarial global survival rate in 5 years was 96.1%.The actuarial survival rate free of biochemical recurrence in 5 years was 83.3% with PSA pre-radiotherapy ≤ 1, 100% when > 1 and ≤ 2, and 57.1% when > 2 (p = 0.023). Dose > 70 Gy in 30% of the bladder volume implied in more acute urinary toxicity (p = 0.035). The mean time for the development of late urinary toxicity was 21 months (12-51). Dose > 55 Gy in 50% bladder volume implied in more late urinary toxicity (p = 0.018). A patient presented late rectal toxicity of second grade. Conclusions: Conformal radiotherapy showed to be effective for the control of biochemical recurrence after radical prostatectomy. Patients with pre-therapy PSA < 2 ng/mL have more biochemical control. (author)

  1. The place of conformal radiotherapy in the routine work: national investigation of SFRO members'opinion

    International Nuclear Information System (INIS)

    Lagrange, J.L.; Lipinski, F.

    2001-01-01

    National French investigation of the using of conformal radiotherapy in routine work, has been made in 2001, in 180 radiotherapeutic centers. Eighty responses have been obtained and analyzed. Conformal radiotherapy is used in 88% and virtual simulation in 60% of these centers. There is a heterogeneity in the equipment of these institutions, most of them have one or two machines. The accelerator equipment differs, and the availability of multi-leaf collimators and electronic portal imaging is limited. Actually only eleven centers have IMRT, eight have projects to install. Only six centers have CT-scans, used mainly for simulation. In 75% of centers conformal radiotherapy have been used in the treatment of CNS-tumors, head and neck cancers, prostate, and non-small cell lung carcinoma. If there are more equipment and human facilities to use conformal radiotherapy, this treatment can be proposed to patients with breast cancer, rectal and gynecological tumors. According 90% of responses, all prostatic cancers need conformal radiotherapy. The analysis of routine use of conformal radiotherapy in France shows an important heterogeneity but it seems that there is an agreement with objectives of this treatment. (authors)

  2. Conformity Index and Homogeneity Index of the Postoperative Whole Breast Radiotherapy.

    Science.gov (United States)

    Petrova, Deva; Smickovska, Snezana; Lazarevska, Emilija

    2017-10-15

    The treatment of breast cancer involves a multidisciplinary approach in which radiotherapy plays a key role. The conformity index and the homogeneity index are two analysis tools of a treatment plan using conformal radiotherapy. The purpose of this article is an analysis of these two parameters in the assessment of the treatment plans in 58 patients undergoing postoperative radiotherapy of the whole breast. All 58 patients participating in the study had a conservatively treated early-stage breast cancer. The treatment was performed using a standard regimen of fractionation in 25 fractions up to a total dose of 50 Gy. Dose-volume histograms were generated for both plans with and without segmental fields. Pair samples t-test was used. The technique with segmental fields allowed us more homogeneity distribution when compared to standard two tangential field techniques. The HI values were 1.08 ± 0.01 and 1.09 ± 0.01 for segment and technique with two tangential fields (p conformity and the homogeneity index are important tools in the analysis of the treatment plans during radiation therapy in patients with early-stage breast cancer. Adding segment fields in the administration of radiotherapy in patients with conservatively treated breast cancer can lead to improved dosage homogeneity and conformity.

  3. Bladder filling variation during conformal radiotherapy for rectal cancer

    Science.gov (United States)

    Sithamparam, S.; Ahmad, R.; Sabarudin, A.; Othman, Z.; Ismail, M.

    2017-05-01

    Conformal radiotherapy for rectal cancer is associated with small bowel toxicity mainly diarrhea. Treating patients with a full bladder is one of the practical solutions to reduce small bowel toxicity. Previous studies on prostate and cervix cancer patients revealed that maintaining consistent bladder volume throughout radiotherapy treatment is challenging. The aim of this study was to measure bladder volume variation throughout radiotherapy treatment. This study also measured the association between bladder volume changes and diarrhea. Twenty two rectal cancer patients were recruited prospectively. Patients were planned for treatment with full bladder following departmental bladder filling protocol and the planning bladder volume was measured during CT-simulation. During radiotherapy, the bladder volume was measured weekly using cone-beam computed tomography (CBCT) and compared to planning bladder volume. Incidence and severity of diarrhea were recorded during the weekly patient review. There was a negative time trend for bladder volume throughout five weeks treatment. The mean bladder volume decreased 18 % from 123 mL (SD 54 mL) during CT-simulation to 101 mL (SD 71 mL) on the 5th week of radiotherapy, but the decrease is not statistically significant. However, there was a large variation of bladder volume within each patient during treatment. This study showed an association between changes of bladder volume and diarrhea (P = 0.045). In conclusion bladder volume reduced throughout radiotherapy treatment for conformal radiotherapy for rectal cancer and there was a large variation of bladder volume within patients.

  4. Bladder filling variation during conformal radiotherapy for rectal cancer

    International Nuclear Information System (INIS)

    Sithamparam, S; Ahmad, R; Sabarudin, A; Othman, Z; Ismail, M

    2017-01-01

    Conformal radiotherapy for rectal cancer is associated with small bowel toxicity mainly diarrhea. Treating patients with a full bladder is one of the practical solutions to reduce small bowel toxicity. Previous studies on prostate and cervix cancer patients revealed that maintaining consistent bladder volume throughout radiotherapy treatment is challenging. The aim of this study was to measure bladder volume variation throughout radiotherapy treatment. This study also measured the association between bladder volume changes and diarrhea. Twenty two rectal cancer patients were recruited prospectively. Patients were planned for treatment with full bladder following departmental bladder filling protocol and the planning bladder volume was measured during CT-simulation. During radiotherapy, the bladder volume was measured weekly using cone-beam computed tomography (CBCT) and compared to planning bladder volume. Incidence and severity of diarrhea were recorded during the weekly patient review. There was a negative time trend for bladder volume throughout five weeks treatment. The mean bladder volume decreased 18 % from 123 mL (SD 54 mL) during CT-simulation to 101 mL (SD 71 mL) on the 5th week of radiotherapy, but the decrease is not statistically significant. However, there was a large variation of bladder volume within each patient during treatment. This study showed an association between changes of bladder volume and diarrhea (P = 0.045). In conclusion bladder volume reduced throughout radiotherapy treatment for conformal radiotherapy for rectal cancer and there was a large variation of bladder volume within patients. (paper)

  5. Constituent Components of Out-of-Field Scatter Dose for 18-MV Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy: A Comparison With 6-MV and Implications for Carcinogenesis

    International Nuclear Information System (INIS)

    Ruben, Jeremy D.; Smith, Ryan; Lancaster, Craig M.; Haynes, Matthew; Jones, Phillip; Panettieri, Vanessa

    2014-01-01

    Purpose: To characterize and compare the components of out-of-field dose for 18-MV intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3D-CRT) and their 6-MV counterparts and consider implications for second cancer induction. Methods and Materials: Comparable plans for each technique/energy were delivered to a water phantom with a sloping wall; under full scatter conditions; with field edge abutting but outside the bath to prevent internal/phantom scatter; and with shielding below the linear accelerator head to attenuate head leakage. Neutron measurements were obtained from published studies. Results: Eighteen-megavolt IMRT produces 1.7 times more out-of-field scatter than 18-MV 3D-CRT. In absolute terms, however, differences are just approximately 0.1% of central axis dose. Eighteen-megavolt IMRT reduces internal/patient scatter by 13%, but collimator scatter (C) is 2.6 times greater than 18-MV 3D-CRT. Head leakage (L) is minimal. Increased out-of-field photon scatter from 18-MV IMRT carries out-of-field second cancer risks of approximately 0.2% over and above the 0.4% from 18-MV 3D-CRT. Greater photoneutron dose from 18-MV IMRT may result in further maximal, absolute increased risk to peripheral tissue of approximately 1.2% over 18-MV 3D-CRT. Out-of-field photon scatter remains comparable for the same modality irrespective of beam energy. Machine scatter (C+L) from 18 versus 6 MV is 1.2 times higher for IMRT and 1.8 times for 3D-CRT. It is 4 times higher for 6-MV IMRT versus 3D-CRT. Reduction in internal scatter with 18 MV versus 6 MV is 27% for 3D-CRT and 29% for IMRT. Compared with 6-MV 3D-CRT, 18-MV IMRT increases out-of-field second cancer risk by 0.2% from photons and adds 0.28-2.2% from neutrons. Conclusions: Out-of-field photon dose seems to be independent of beam energy for both techniques. Eighteen-megavolt IMRT increases out-of-field scatter 1.7-fold over 3D-CRT because of greater collimator scatter despite

  6. Gastro-intestinal and genito-urinary morbidity after 3D conformal radiotherapy of prostate cancer: observations of a randomized trial

    International Nuclear Information System (INIS)

    Koper, Peter C.; Jansen, Peter; Putten, Wim van; Os, Marjolein van; Wijnmaalen, Arend J.; Lebesque, Joos V.; Levendag, Peter C.

    2004-01-01

    Background and purpose: The late morbidity of a randomized study was analyzed after a follow up of 2 years. The difference in intestinal morbidity was analyzed as a function of the treatment arm and dose volume parameters. The correlation with acute toxicity and (pre-existing) bowel complaints was investigated. Patients and methods: 266 T1-4N0M0 prostate cancer patients were randomized for conventional (open fields) and 3D conformal radiotherapy using beams eye view blocked fields with the same dose (66 Gy) and gross target volume-planning target volume margin (15 mm). Apart from the RTOG toxicity scoring system a patient self-assessment questionnaire was used to obtain detailed information on morbidity. Results: At 2 years there is only a trend for less rectal toxicity (grade≥1) in favor of the conformal radiotherapy (grade 1, 47 versus 40% and grade 2, 10 versus 7% for conventional and conformal radiotherapy, respectively (P=0.1). A significant relation was found between late rectal toxicity (grade≥1) and the volume of the anus and rectum exposed to≥90% tumor dose (TD). A highly significant relationship is observed between acute rectum and anal toxicity and late rectal toxicity. The patient self-assessment questionnaire analysis revealed that patients are most bothered by compliance related symptoms like urgency, soiling and fecal loss. In a multivariate analysis, all other variables loose significance, when anal volume exposed to≥90% TD and pre-treatment defaecation frequency are accounted for. Late anal toxicity is low and related only to acute anal toxicity. Late bladder toxicity is related solely to pre-treatment frequency and overall urological symptoms. The incidence of grade 2 toxicity increases with a factor 2.5-4 when (stool or urine) frequency is unfavorable at the start of treatment. Conclusions: Conformal radiotherapy at the dose level of 66 Gy does not significantly decrease the incidence of rectal, anal and bladder toxicity compared to

  7. Analysis of second malignancies after modern radiotherapy versus prostatectomy for localized prostate cancer

    International Nuclear Information System (INIS)

    Huang Jiayi; Kestin, Larry L.; Ye, Hong; Wallace, Michelle; Martinez, Alvaro A.; Vicini, Frank A.

    2011-01-01

    Purpose: To clarify the risk of developing second primary cancers (SPCs) after radiotherapy (RT) versus prostatectomy for localized prostate cancer (PCa) in the modern era. Methods: The RT cohort consisted of 2120 patients matched on a 1:1 basis with surgical patients according to age and follow-up time. RT techniques consisted of conventional or two-dimensional RT (2DRT, 36%), three-dimensional conformal RT and/or intensity modulated RT (3DCRT/IMRT, 29%), brachytherapy (BT, 16%), and a combination of 2DRT and BT (BT boost, 19%). Results: The overall SPC risk was not significantly different between the matched-pair (HR 1.14, 95% CI 0.94-1.39), but the risk became significant >5 years or >10 years after RT (HR 1.86, 95% CI 1.36-2.55; HR 4.94, 95% CI 2.18-11.2, respectively). The most significant sites of increased risk were bladder, lymphoproliferative, and sarcoma. Of the different RT techniques, only 2DRT was associated with a significantly higher risk (HR 1.76, 95% CI 1.32-2.35), but not BT boost (HR 0.83, 95% CI 0.50-1.38), 3DCRT/IMRT (HR 0.81, 95% CI 0.55-1.21), or BT (HR 0.53, 95% CI 0.28-1.01). Conclusions: Radiation-related SPC risk varies depending on the RT technique and may be reduced by using BT, BT boost, or 3DCRT/IMRT.

  8. Beam angle selection for intensity-modulated radiotherapy (IMRT) treatment of unresectable pancreatic cancer: are noncoplanar beam angles necessary?

    Science.gov (United States)

    Chang, D S; Bartlett, G K; Das, I J; Cardenes, H R

    2013-09-01

    External beam radiation therapy with concurrent chemotherapy (CRT) is widely used for the treatment of unresectable pancreatic cancer. Noncoplanar (NCP) 3D conformal radiotherapy (3DCRT) and coplanar (CP) IMRT have been reported to lower the radiation dose to organs at risk (OARs). The purpose of this article is to examine the utility of noncoplanar beam angles in IMRT for the management of pancreatic cancer. Sixteen patients who were treated with CRT for unresectable adenocarcinoma of the pancreatic head or neck were re-planned using CP and NCP beams in 3DCRT and IMRT with the Varian Eclipse treatment planning system. Compared to CP IMRT, NCP IMRT had similar target coverage with slightly increased maximum point dose, 5,799 versus 5,775 cGy (p = 0.008). NCP IMRT resulted in lower mean kidney dose, 787 versus 1,210 cGy (p kidney dose, but did not improve other dose-volume criteria. The use of NCP beam angles is preferred only in patients with risk factors for treatment-related kidney dysfunction.

  9. Australian and New Zealand three-dimensional conformal radiation therapy consensus guidelines for prostate cancer

    International Nuclear Information System (INIS)

    Skala, M.; Berry, M.; Kneebone, A.; Gogna, K.; Turner, S.; Rolfo, A.; Haworth, A.

    2004-01-01

    Three-dimensional conformal radiation therapy (3DCRT) has been shown to reduce normal tissue toxicity and allow dose escalation in the curative treatment of prostate cancer. The Faculty of Radiation Oncology Genito-Urinary Group initiated a consensus process to generate evidence-based guidelines for the safe and effective implementation of 3DCRT. All radiation oncology departments in Australia and New Zealand were invited to complete a survey of their prostate practice and to send representatives to a consensus workshop. After a review of the evidence, key issues were identified and debated. If agreement was not reached, working parties were formed to make recommendations. Draft guidelines were circulated to workshop participants for approval prior to publication. Where possible, evidence-based recommendations have been made with regard to patient selection, risk stratification, simulation, planning, treatment delivery and toxicity reporting. This is the first time a group of radiation therapists, physicists and oncologists representing professional radiotherapy practice across Australia and New Zealand have worked together to develop best-practice guidelines. These guidelines should serve as a baseline for prospective clinical trials, outcome research and quality assurance. Copyright (2004) Blackwell Science Pty Ltd

  10. Comparative analysis of dosimetric parameters of three different radiation techniques for patients with Graves’ ophthalmopathy treated with retro-orbital irradiation

    International Nuclear Information System (INIS)

    Lee, Victor HF; Ng, Sherry CY; Choi, Cheuk Wai; Luk, Mai Yee; Leung, To Wai; Au, Gordon KH; Kwong, Dora LW

    2012-01-01

    We would like to investigate the if IMRT produced better target coverage and dose sparing to adjacent normal structures as compared with 3-dimensional conformal radiotherapy (3DCRT) and lateral opposing fields (LOF) for patients with Graves’ ophthalmopathy treated with retro-orbital irradiation. Ten consecutive patients diagnosed with Graves’ ophthalmopathy were prospectively recruited into this study. An individual IMRT, 3DCRT and LOF plan was created for each patient. Conformity index (CI), homogeneity index (HI) and other dosimetric parameters of the targets and organs-at-risk (OAR) generated by IMRT were compared with the other two techniques. Mann–Whitney U test demonstrated that CI generated by IMRT was superior to that produced by 3DCRT and LOF (p=0.005 for both respectively). Similarly HI with IMRT was proven better than 3DCRT (p=0.007) and LOF (p=0.005). IMRT gave rise to better dose sparing to some OARs including globes, lenses and optic nerves as compared with 3DCRT but not with LOF. IMRT, as compared with 3DCRT and LOF, was found to have a better target coverage, conformity and homogeneity and dose sparing to some surrounding structures, despite a slight increase but clinically negligible dose to other structures. Dosimetrically it might be a preferred treatment technique and a longer follow up is warranted to establish its role in routine clinical use

  11. Intensity-modulated three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Mohan, Radhe

    1996-01-01

    Optimized intensity-modulated treatments one of the important advances in photon radiotherapy. Intensity modulation provides a greatly increased control over dose distributions. Such control can be maximally exploited to achieve significantly higher levels of conformation to the desired clinical objectives using sophisticated optimization techniques. Safe, rapid and efficient delivery of intensity-modulated treatments has become feasible using a dynamic multi-leaf collimator under computer control. The need for all other field shaping devices such as blocks, wedges and compensators is eliminated. Planning and delivery of intensity-modulated treatments is amenable to automation and development of class solutions for each treatment site and stage which can be implemented not only at major academic centers but on a wide scale. A typical treatment involving as many as 10 fields can be delivered in times shorter than much simpler conventional treatments. The main objective of the course is to give an overview of the current state of the art of planning and delivery methods of intensity-modulated treatments. Specifically, the following topics will be covered using representative optimized plans and treatments: 1. A typical procedure for planning and delivering an intensity-modulated treatment. 2. Quantitative definition of criteria (i.e., the objective function) of optimization of intensity-modulated treatments. Clinical relevance of objectives and the dependence of the quality of optimized intensity-modulated plans upon whether the objectives are stated purely in terms of simple dose or dose-volume criteria or whether they incorporate biological indices. 3. Importance of the lateral transport of radiation in the design of intensity-modulated treatments. Impact on dose homogeneity and the optimum choice of margins. 4. Use of intensity-modulated treatments in escalation of tumor dose for the same or lower normal tissue dose. Fractionation of intensity-modulated treatments

  12. Intensity-modulated three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Mohan, Radhe

    1997-01-01

    Optimized intensity-modulated treatments one of the important advances in photon radiotherapy. Intensity modulation provides a greatly increased control over dose distributions. Such control can be maximally exploited to achieve significantly higher levels of conformation to the desired clinical objectives using sophisticated optimization techniques. Safe, rapid and efficient delivery of intensity-modulated treatments has become feasible using a dynamic multi-leaf collimator under computer control. The need for all other field shaping devices such as blocks, wedges and compensators is eliminated. Planning and delivery of intensity-modulated treatments is amenable to automation and development of class solutions for each treatment site and stage which can be implemented not only at major academic centers but on a wide scale. A typical treatment involving as many as 10 fields can be delivered in times shorter than much simpler conventional treatments. The main objective of the course is to give an overview of the current state of the art of planning and delivery methods of intensity-modulated treatments. Specifically, the following topics will be covered using representative optimized plans and treatments: 1. A typical procedure for planning and delivering an intensity-modulated treatment. 2. Quantitative definition of criteria (i.e., the objective function) of optimization of intensity-modulated treatments. Clinical relevance of objectives and the dependence of the quality of optimized intensity-modulated plans upon whether the objectives are stated purely in terms of simple dose or dose-volume criteria or whether they incorporate biological indices. 3. Importance of the lateral transport of radiation in the design of intensity-modulated treatments. Impact on dose homogeneity and the optimum choice of margins. 4. Use of intensity-modulated treatments in escalation of tumor dose for the same or lower normal tissue dose. Fractionation of intensity-modulated treatments

  13. Sildenafil citrate (Viagra) and erectile dysfunction following external beam radiotherapy for prostate cancer: a randomized, double-blind, placebo-controlled, cross-over study

    International Nuclear Information System (INIS)

    Incrocci, Luca; Koper, Peter C.M.; Hop, Wim C.J.; Slob, A. Koos

    2001-01-01

    Purpose: To determine the efficacy of sildenafil citrate (Viagra) in patients with erectile dysfunction after three-dimensional conformal external beam radiotherapy (3D-CRT) for prostate cancer. Methods and Materials: 406 patients with complaints of erectile dysfunction and who completed radiation at least 6 months before the study were approached by mail. 3D-CRT had been delivered (mean dose 68 Gy). Sixty patients were included and entered a double-blind, placebo-controlled, cross-over study lasting 12 weeks. They received during 2 weeks 50 mg of sildenafil or placebo; at Week 2 the dose was increased to 100 mg in case of unsatisfactory erectile response. At Week 6, patients crossed over to the alternative treatment. Data were collected using the International Index of Erectile Function (IIEF) questionnaire, and side effects were recorded. Results: Mean age was 68 years. All patients completed the study. For most questions of the IIEF questionnaire there was a significant increase in mean scores from baseline with sildenafil, but not with placebo. Ninety percent of the patients needed a dose adjustment to 100 mg sildenafil. Side effects were mild or moderate. Conclusion: Sildenafil is well tolerated and effective in improving erectile function of patients with ED after 3D-CRT for prostate cancer

  14. Radiological response and dosimetry in physical phantom of head and neck for 3D conformational radiotherapy

    International Nuclear Information System (INIS)

    Thompson, Larissa

    2013-01-01

    Phantoms are tools for simulation of organs and tissues of the human body in radiology and radiotherapy. This thesis describes the development, validation and, most importantly, the use of a physical head and neck phantom in radiology and radiotherapy, with the purpose of evaluating dose distribution using Gafchromic EBT2 film in 15 MV 3D conformal radiotherapy. The work was divided in two stages, (1) development of new equivalent tissues and improvement of the physical phantom, and (2) use of the physical phantom in experimental dosimetry studies. In phase (1) parameters such as mass density, chemical composition of tissues, anatomical and biometric measurements were considered, as well as aspects of imaging by computed tomography (CT) and radiological response representation in Hounsfield Units (HU), which were compared with human data. Radiological experiments of in-phantom simulated brain pathologies were also conducted. All those results matched human-sourced data, therefore the physical phantom is a suitable simulator that may be used to enhance radiological protocols and education in medical imaging. The main objective in phase (2) was to evaluate the spatial dose distribution in a brain tumor simulator inserted inside the head and neck phantom developed by the Ionizing Radiation Research Group (NRI), exposed to 15 MV 3D conformal radiotherapy, for internal dose assessment. Radiation planning was based on CT images of the physical phantom with a brain tumor simulator made with equivalent material. The treatment planning system (TPS), CAT3D software, used CT images and prescribed a dose of 200 cGy, distributed in three fields of radiation, in a T-shaped pattern. The TPS covered the planning treatment volume (PTV) with 97% of the prescribed dose. A solid water phantom and radiochromic Gafchromic EBT2 film were used for calibration procedures, generating a dose response curve as a function of optical density (OD). After calibration and irradiation, the film

  15. A case study of radiotherapy planning for a bilateral metal hip prosthesis prostate cancer patient

    International Nuclear Information System (INIS)

    Su, Andy; Reft, Chester; Rash, Carla; Price, Jennifer; Jani, Ashesh B.

    2005-01-01

    The purpose of this report is to communicate the observed advantage of intensity-modulated radiotherapy (IMRT) in a patient with bilateral metallic hip prostheses. In this patient with early-stage low-risk disease, a dose of 74 Gy was planned in two phases-an initial 50 Gy to the prostate and seminal vesicles and an additional 24 Gy to the prostate alone. Each coplanar beam avoided the prosthesis in the beam's eye view. Using the same target expansions for each phase, IMRT and 3D-conformal radiotherapy (CRT) plans were compared for target coverage and inhomogeneity as well as dose to the bladder and rectum. The results of the analysis demonstrated that IMRT provided superior target coverage with reduced dose to normal tissues for both individual phases of the treatment plan as well as for the composite treatment plan. The dose to the rectum was significantly reduced with the IMRT technique, with a composite V80 of 35% for the IMRT plan versus 70% for 3D-CRT plan. Similarly, the dose to the bladder was significantly reduced with a V80 of 9% versus 20%. Overall, various dosimetric parameters revealed the corresponding 3D-CRT plan would not have been acceptable. The results indicate significant success with IMRT in a clinical scenario where there were no curative alternatives for local treatment other than external beam radiotherapy. Therefore, definitive external beam radiation of prostate cancer patients with bilateral prosthesis is made feasible with IMRT. The work described herein may also have applicability to other groups of patients, such as those with gynecological or other pelvic malignancies

  16. Optimized volumetric modulated arc therapy versus 3D-CRT for early stage mediastinal Hodgkin lymphoma without axillary involvement: a comparison of second cancers and heart disease risk.

    Science.gov (United States)

    Filippi, Andrea Riccardo; Ragona, Riccardo; Piva, Cristina; Scafa, Davide; Fiandra, Christian; Fusella, Marco; Giglioli, Francesca Romana; Lohr, Frank; Ricardi, Umberto

    2015-05-01

    The purpose of this study was to evaluate the risks of second cancers and cardiovascular diseases associated with an optimized volumetric modulated arc therapy (VMAT) planning solution in a selected cohort of stage I/II Hodgkin lymphoma (HL) patients treated with either involved-node or involved-site radiation therapy in comparison with 3-dimensional conformal radiation therapy (3D-CRT). Thirty-eight patients (13 males and 25 females) were included. Disease extent was mediastinum alone (n=8, 21.1%); mediastinum plus unilateral neck (n=19, 50%); mediastinum plus bilateral neck (n=11, 29.9%). Prescription dose was 30 Gy in 2-Gy fractions. Only 5 patients had mediastinal bulky disease at diagnosis (13.1%). Anteroposterior 3D-CRT was compared with a multiarc optimized VMAT solution. Lung, breast, and thyroid cancer risks were estimated by calculating a lifetime attributable risk (LAR), with a LAR ratio (LAR(VMAT)-to-LAR(3D-CRT)) as a comparative measure. Cardiac toxicity risks were estimated by calculating absolute excess risk (AER). The LAR ratio favored 3D-CRT for lung cancer induction risk in mediastinal alone (P=.004) and mediastinal plus unilateral neck (P=.02) presentations. LAR ratio for breast cancer was lower for VMAT in mediastinal plus bilateral neck presentations (P=.02), without differences for other sites. For thyroid cancer, no significant differences were observed, regardless of anatomical presentation. A significantly lower AER of cardiac (P=.038) and valvular diseases (Pdisease extent. In a cohort of patients with favorable characteristics in terms of disease extent at diagnosis (large prevalence of nonbulky presentations without axillary involvement), optimized VMAT reduced heart disease risk with comparable risks of thyroid and breast cancer, with an increase in lung cancer induction probability. The results are however strongly influenced by the different anatomical presentations, supporting an individualized approach. Copyright © 2015 Elsevier

  17. Dosimetric comparison of axilla and groin radiotherapy techniques for high-risk and locally advanced skin cancer

    International Nuclear Information System (INIS)

    Mattes, Malcolm D.; Zhou, Ying; Berry, Sean L.; Barker, Christopher A.

    2016-01-01

    Radiation therapy targeting axilla and groin lymph nodes improves regional disease control in locally advanced and high-risk skin cancers. However, trials generally used conventional two-dimensional radiotherapy (2D-RT), contributing towards relatively high rates of side effects from treatment. The goal of this study is to determine if three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), or volumetric-modulated arc therapy (VMAT) may improve radiation delivery to the target while avoiding organs at risk in the clinical context of skin cancer regional nodal irradiation. Twenty patients with locally advanced/high-risk skin cancers underwent computed tomography simulation. The relevant axilla or groin planning target volumes and organs at risk were delineated using standard definitions. Paired t-tests were used to compare the mean values of several dose-volumetric parameters for each of the 4 techniques. In the axilla, the largest improvement for 3D-CRT compared to 2D-RT was for homogeneity index (13.9 vs. 54.3), at the expense of higher lung V 20 (28.0% vs. 12.6%). In the groin, the largest improvements for 3D-CRT compared to 2D-RT were for anorectum D max (13.6 vs. 38.9 Gy), bowel D 200cc (7.3 vs. 23.1 Gy), femur D 50 (34.6 vs. 57.2 Gy), and genitalia D max (37.6 vs. 51.1 Gy). IMRT had further improvements compared to 3D-CRT for humerus D mean (16.9 vs. 22.4 Gy), brachial plexus D 5 (57.4 vs. 61.3 Gy), bladder D 5 (26.8 vs. 36.5 Gy), and femur D 50 (18.7 vs. 34.6 Gy). Fewer differences were observed between IMRT and VMAT. Compared to 2D-RT and 3D-CRT, IMRT and VMAT had dosimetric advantages in the treatment of nodal regions of skin cancer patients

  18. Dosimetric comparison of axilla and groin radiotherapy techniques for high-risk and locally advanced skin cancer

    Energy Technology Data Exchange (ETDEWEB)

    Mattes, Malcolm D.; Zhou, Ying; Berry, Sean L.; Barker, Christopher A. [Memorial Sloan Kettering Cancer Center, New York (United States)

    2016-06-15

    Radiation therapy targeting axilla and groin lymph nodes improves regional disease control in locally advanced and high-risk skin cancers. However, trials generally used conventional two-dimensional radiotherapy (2D-RT), contributing towards relatively high rates of side effects from treatment. The goal of this study is to determine if three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), or volumetric-modulated arc therapy (VMAT) may improve radiation delivery to the target while avoiding organs at risk in the clinical context of skin cancer regional nodal irradiation. Twenty patients with locally advanced/high-risk skin cancers underwent computed tomography simulation. The relevant axilla or groin planning target volumes and organs at risk were delineated using standard definitions. Paired t-tests were used to compare the mean values of several dose-volumetric parameters for each of the 4 techniques. In the axilla, the largest improvement for 3D-CRT compared to 2D-RT was for homogeneity index (13.9 vs. 54.3), at the expense of higher lung V{sub 20} (28.0% vs. 12.6%). In the groin, the largest improvements for 3D-CRT compared to 2D-RT were for anorectum D{sub max} (13.6 vs. 38.9 Gy), bowel D{sub 200cc} (7.3 vs. 23.1 Gy), femur D{sub 50} (34.6 vs. 57.2 Gy), and genitalia D{sub max} (37.6 vs. 51.1 Gy). IMRT had further improvements compared to 3D-CRT for humerus D{sub mean} (16.9 vs. 22.4 Gy), brachial plexus D{sub 5} (57.4 vs. 61.3 Gy), bladder D{sub 5} (26.8 vs. 36.5 Gy), and femur D{sub 50} (18.7 vs. 34.6 Gy). Fewer differences were observed between IMRT and VMAT. Compared to 2D-RT and 3D-CRT, IMRT and VMAT had dosimetric advantages in the treatment of nodal regions of skin cancer patients.

  19. Probability of mediastinal involvement in non-small-cell lung cancer: a statistical definition of the clinical target volume for 3-dimensional conformal radiotherapy?

    International Nuclear Information System (INIS)

    Giraud, Philippe; De Rycke, Yann; Lavole, Armelle; Milleron, Bernard; Cosset, Jean-Marc; Rosenzweig, Kenneth E.

    2006-01-01

    Purpose: Conformal irradiation (3D-CRT) of non-small-cell lung carcinoma (NSCLC) is largely based on precise definition of the nodal clinical target volume (CTVn). A reduction of the number of nodal stations to be irradiated would facilitate tumor dose escalation. The aim of this study was to design a mathematical tool based on documented data to predict the risk of metastatic involvement for each nodal station. Methods and Materials: We reviewed the large surgical series published in the literature to identify the main pretreatment parameters that modify the risk of nodal invasion. The probability of involvement for the 17 nodal stations described by the American Thoracic Society (ATS) was computed from all these publications. Starting with the primary site of the tumor as the main characteristic, we built a probabilistic tree for each nodal station representing the risk distribution as a function of each tumor feature. Statistical analysis used the inversion of probability trees method described by Weinstein and Feinberg. Validation of the software based on 134 patients from two different populations was performed by receiver operator characteristic (ROC) curves and multivariate logistic regression. Results: Analysis of all of the various parameters of pretreatment staging relative to each level of the ATS map results in 20,000 different combinations. The first parameters included in the tree, depending on tumor site, were histologic classification, metastatic stage, nodal stage weighted as a function of the sensitivity and specificity of the diagnostic examination used (positron emission tomography scan, computed tomography scan), and tumor stage. Software is proposed to compute a predicted probability of involvement of each nodal station for any given clinical presentation. Double cross validation confirmed the methodology. A 10% cutoff point was calculated from ROC and logistic model giving the best prediction of mediastinal lymph node involvement. Conclusion

  20. Brainstem tolerance to conformal radiotherapy of skull base tumors

    International Nuclear Information System (INIS)

    Debus, J.; Hug, E.B.; Munzenrider, J.E.; Liebsch, N.J.; O'Farrell, D.; Efird, J.; Daly, W.; Suit, H.D.

    1996-01-01

    Purpose/Objective: Brainstem tolerance to inhomogenous radiation doses applied by modern conformal radiotherapy has not yet been examined. The aim of this study was to analyse the incidence of brainstem toxicity in patients treated for skull base tumors with high dose conformal radiotherapy. Materials and Methods: Between 1974 and 1995, 367 patients with chordomas (n=195) and chondrosarcomas (n=172) of the base of skull have been treated with combined megavoltage photon and 160 MeV proton radiotherapy. All patients had previously undergone biopsy, subtotal or total tumor removal. 104 patients had two or more surgical procedures before radiotherapy. Following 3D treatment planning with delineation of target volumes and critical non-target structures, dose distributions and dose volume histograms were calculated [at the time of treatment delivery]. Radiotherapy was given once a day, 1.8 Gy or CGE (Cobalt Gy Equivalent: Proton Gy X 1.1) per fraction, 5 fractions per week, with prescribed target doses ranging from 63 CGE to 79.2 CGE (mean = 67.8 CGE). Doses to the brainstem surface were limited to ≤64 CGE and to the brainstem center to ≤53 CGE. Dose distributions were developed to limit dose to brainstem surface and center; current plans limit dose to surface and center to ≤64 CGE and ≤53 CGE, respectively. Brainstem toxicity was scored according to the RTOG grading system. Results: Follow-up ranged from 6 months to 21.4 years (mean = 42.5 months). Brainstem symptoms, attributable to the treatment, developed in 17 of 282 patients with local tumor control (6.0%), resulting in death of three patients. The mean time to onset of symptoms was 17 months (range: 4.5 to 177 months). These symptoms appeared in 89.5% within 3 years. Grading of the brainstem toxicity is listed in table 1. Actuarial rates of 5 and 10 year toxicity free survival were 87% and 82% respectively. Increased risk of brainstem toxicity was significantly associated with maximum brainstem dose

  1. Conformal three dimensional radiotherapy treatment planning in Lund

    International Nuclear Information System (INIS)

    Knoos, T.; Nilsson, P.; Anders, A.

    1995-01-01

    The use of conformal therapy is based on 3-dimensional treatment planning as well as on methods and routines for 3-dimensional patient mapping, 3-dimensional virtual simulation and others. The management of patients at the Radiotherapy Department at the University Hospital in Lund (Sweden) is discussed. About 2100 new patients are annually treated with external radiotherapy using seven linear accelerators. Three of the accelerators have dual photon energies and electron treatment facilities. A multi-leaf collimator as well as an electronic portal imaging device are available on one machine. Two simulators and an in-house CT-scanner are used for treatment planning. From 1988 to 1992 Scandiplan (Umplan) was used. Since 1992, the treatment planning system is TMS (HELAX AB, Sweden), which is based on the pencil beam algorithm of Ahnesjo. The calculations use patient modulated accelerator specific energy fluence spectra which are compiled with pencil beams from Monte Carlo generated energy absorption kernels. Heterogeneity corrections are performed with results close to conventional algorithms. Irregular fields, either from standard or individual blocks and from multi-leaf collimators are handled by the treatment planning system. The field shape is determined conveniently using the beam's eye view. The final field shape is exported electronically to either the block cutting machine or the multileaf collimator control computer. All patient fields are checked against the beam's eye view during simulation using manual methods. Treatment verification is performed by portal films and in vivo dosimetry with silicon diodes or TL-dosimetry. Up to now, approximately 4400 patients have received a highly individualized 3-dimensional conformal treatment

  2. Comparisons of dose-volume histograms for proton-beam versus 3-D conformal X-ray therapy in patients with stage I non-small cell lung cancer

    International Nuclear Information System (INIS)

    Wang, Changlu; Nakayama, Hidetsugu; Sugahara, Shinji; Sakae, Takeji; Tokuuye, Koichi

    2009-01-01

    Dose-volume histograms (DVHs) were reviewed to determine if there is an advantage of the two modalities when treating patients with non-small cell lung cancer (NSCLC). 24 stage I NSCLC patients who underwent proton-beam therapy (PBT) from June 2003 to May 2007 were included in this study. Based on the same clinical target volumes (CTVs), treatment planning was made to cover CTV within 90% isodose lines. Each patient was evaluated by two sets of DVHs, one for PBT and the other for three-dimensional conformal X-ray therapy (3D-CRT). For all patients, the 95% isodose line covered 86.4% of the CTV for PBT, and 43.2% for 3D-CRT. PBT was associated with significantly lower mean doses to the ipsilateral lung, total lung, heart, esophagus, and spinal cord than 3D-CRT. PBT offered reduced radiation doses to the lung when evaluated in terms of percentage lung volumes receiving ≥ 5 Gy (V 5 ), ≥ 10 Gy (V 10 ), and ≥ 20 Gy (V 20 ) when compared to 3D-CRT. PBT is advantageous over 3D-CRT in reducing doses to the lung, heart, esophagus, and spinal cord in treating stage I NSCLC. (orig.)

  3. Late rectal toxicity after conformal radiotherapy of prostate cancer (I): multivariate analysis and dose-response

    International Nuclear Information System (INIS)

    Skwarchuk, Mark W.; Jackson, Andrew; Zelefsky, Michael J.; Venkatraman, Ennapadam S.; Cowen, Didier M.; Levegruen, Sabine; Burman, Chandra M.; Fuks, Zvi; Leibel, Steven A.; Ling, C. Clifton

    2000-01-01

    Purpose: The purpose of this paper is to use the outcome of a dose escalation protocol for three-dimensional conformal radiation therapy (3D-CRT) of prostate cancer to study the dose-response for late rectal toxicity and to identify anatomic, dosimetric, and clinical factors that correlate with late rectal bleeding in multivariate analysis. Methods and Materials: Seven hundred forty-three patients with T1c-T3 prostate cancer were treated with 3D-CRT with prescribed doses of 64.8 to 81.0 Gy. The 5-year actuarial rate of late rectal toxicity was assessed using Kaplan-Meier statistics. A retrospective dosimetric analysis was performed for patients treated to 70.2 Gy (52 patients) or 75.6 Gy (119 patients) who either exhibited late rectal bleeding (RTOG Grade 2/3) within 30 months after treatment (i.e., 70.2 Gy--13 patients, 75.6 Gy--36 patients) or were nonbleeding for at least 30 months (i.e., 70.2 Gy--39 patients, 75.6 Gy--83 patients). Univariate and multivariate logistic regression was performed to correlate late rectal bleeding with several anatomic, dosimetric, and clinical variables. Results: A dose response for ≥ Grade 2 late rectal toxicity was observed. By multivariate analysis, the following factors were significantly correlated with ≥ Grade 2 late rectal bleeding for patients prescribed 70.2 Gy: 1) enclosure of the outer rectal contour by the 50% isodose on the isocenter slice (i.e., Iso50) (p max (p max

  4. Phase I study of conformal radiotherapy with concurrent gemcitabine in locally advanced bladder cancer

    International Nuclear Information System (INIS)

    Sangar, Vijay K.; McBain, Catherine A.; Lyons, Jeanette; Ramani, Vijay; Logue, John; Wylie, James; Clarke, Noel W.; Cowan, Richard A.

    2005-01-01

    Purpose: A prospective phase I trial was conducted to determine the maximal tolerated dose of gemcitabine given once weekly during hypofractionated conformal radiotherapy to patients with locally advanced transitional cell carcinoma of the bladder. Eight male patients, median age 69 years, with Stage T2 (n = 4) or T3 (n = 4) N0M0, were enrolled in cohorts of 3. Treatment comprised conformal radiotherapy (52.5 Gy in 20 fractions) within 4 weeks, with concurrent gemcitabine once weekly for four cycles. The weekly gemcitabine dose was escalated from 100 mg/m 2 in increments of 50 mg/m 2 per cohort. Dose-limiting toxicity was defined as any acute Radiation Therapy Oncology Group (RTOG) toxicity Grade 3 or greater arising in >1 of 3 patients in each cohort. Tumor response was assessed cystoscopically and radiologically at 3 months. Results: All 8 patients completed radiotherapy, and 6 of 8 completed chemoradiotherapy. No acute toxicity greater than RTOG Grade 1 was seen with gemcitabine at 100 mg/m 2 . Dose-limiting toxicity was observed at 150 mg/m 2 with Grade 3 toxicity seen in 2 of 2 patients (one bladder, one bowel). An additional 3 patients received 100 mg/m 2 with minimal toxicity. No hematologic toxicity was encountered. A complete response was seen in 7 (87.5%) of 8 patients, all of whom were disease free at a median follow-up of 19.5 months (range, 14-23 months). No late toxicity (greater than RTOG Grade 0) has been observed. Conclusion: The maximal tolerated dose for gemcitabine given once weekly with concurrent hypofractionated conformal bladder radiotherapy was 150 mg/m 2 , with a maximal recommended dose of 100 mg/m 2 . This dose regimen has now entered Phase II clinical trials

  5. Thoracic radiotherapy and breath control: current prospects; Radiotherapie thoracique et controle de la respiration: perspectives actuelles

    Energy Technology Data Exchange (ETDEWEB)

    Reboul, F.; Mineur, L.; Paoli, J.B.; Bodez, V.; Oozeer, R.; Garcia, R. [Institut Sainte-Catherine, 84 - Avignon (France)

    2002-11-01

    Three-dimensional conformal radiotherapy (3D CRT) is adversely affected by setup error and organ motion. In thoracic 3D CRT, breathing accounts for most of intra-fraction movements, thus impairing treatment quality. Breath control clearly exhibits dosimetric improvement compared to free breathing, leading to various techniques for gated treatments. We review benefits of different breath control methods -i.e. breath-holding or beam gating, with spirometric, isometric or X-ray respiration sensor- and argument the choice of expiration versus inspiration, with consideration to dosimetric concerns. All steps of 3D-CRT can be improved with breath control. Contouring of organs at risk (OAR) and target are easier and more accurate on breath controlled CT-scans. Inter- and intra-fraction target immobilisation allows smaller margins with better coverage. Lung outcome predictors (NTCP, Mean Dose, LV20, LV30) are improved with breath-control. In addition, inspiration breath control facilitates beam arrangement since it widens the distance between OAR and target, and leaves less lung normal tissue within the high dose region. Last, lung density, as of CT scan, is more accurate, improving dosimetry. Our institutions choice is to use spirometry driven, patient controlled high-inspiration breath-hold; this technique gives excellent immobilization results, with high reproducibility, yet it is easy to implement and costs little extra treatment time. Breath control, whatever technique is employed, proves superior to free breathing treatment when using 3D-CRT. Breath control should then be used whenever possible, and is probably mandatory for IMRT. (authors)

  6. Concurrent chemoradiation of metastases with capecitabine and oxaliplatin and 3D-CRT in patients with oligometastatic colorectal cancer: results of a phase I study

    Directory of Open Access Journals (Sweden)

    Dellas Kathrin

    2012-06-01

    Full Text Available Abstract Background Local control appears to be an important treatment aim in patients with limited metastases (oligometastases of colorectal cancer (CRC. Those patients show a favourable prognosis, if - in addition to the local effective treatment - an occurrence of new metastases may also be postponed by effective systemic therapy. The purpose of this dose escalation phase I study was to establish the efficacy of local radiotherapy (RT of oligometastatic CRC with a concurrent standard chemotherapy regimen. Methods Patients with first-, second- or third-line therapy of oligometastatic CRC (1–3 metastases or local recurrence plus max. 2 metastases received capecitabine (825 mg/m2/d BID d 1–14; 22–35 and oxaliplatin (50 mg/m2 d 1, 8, 22, 29. 3D-conformal RT of all metastatic lesions was delivered in 2.0 Gy up to 36 Gy to 50 Gy (3 dose levels. Primary endpoint was the maximal tolerable dose (MTD of RT defined as the level at which two or more of six patients experienced dose-limiting toxicity (DLT. Results Between 09/2004 and 08/2007, 9 patients (7 male, 2 female, 50–74 years were enrolled, 6 patients treated at dose level 1 (36 Gy, 3 patients at dose level 2 (44 Gy. 1 patient from the first cohort experienced DLT (oxaliplatin-related hypersensitivity reaction. No radiation-induced DLT occurred. 6/9 patients achieved objective response (partial remission. One year after initiation, all patients were alive, 6 patients survived (16 to 54 months patients died of tumor progression (14 to 23 months. The phase II part of the trial had to be closed due to recruitment failure. Conclusions Local 3D-CRT to metastatic lesions in addition to standard chemotherapy was feasible, DLT was not documented. 3/9 patients survived for a period of 3.5 to 4.4 years (time at the last evaluation. Radiotherapy of metastatic lesions should be incorporated into subsequent trials.

  7. Quality of life following 3D conformal radiation therapy or permanent interstitial brachytherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Michalski, J.M.; Kong, F.M.; Mansur, D.B.; Ahmed, N.; Perez, C.A.

    2001-01-01

    Purpose: Both 3D Conformal Radiation Therapy (3DCRT) and Transperineal Interstitial Permanent Brachytherapy (TIPPB) are offered as suitable non-surgical alternatives to radical prostatectomy. Despite equivalent cancer control, very little data has been published that compares Quality of Life (QOL) in contemporary cohorts of patients choosing these treatments. Materials and Methods: Since 1998, patients selecting either 3DCRT alone or TIPPB (monotherapy or boost after external beam) for primary management of localized prostate cancer were asked to participate in a prospective assessment of QOL measures. In this preliminary report, 41 3DCRT and 40 TIPPB (34 monotherapy, 6 boost) patients completed validated QOL instruments at each followup visit. QOL instruments included the International Prostate Symptom Score (IPSS), FACT-P, and Sexual Adjustment Questionnaire (SAQ). Results: The average age of men in each group was 69 years. Choice of treatment was left to the patient unless there were significant medical or technical contraindications to either modality. 3DCRT total doses ranged from 61-78 Gy (mean 73.5Gy) and TIPPB doses were 145Gy (TG43) in 34 I-125 implants and 115 Gy in 1 Pd-103 (monotherapy) or 90 Gy in 5 Pd-103 (boost) implants. Patients undergoing TIPPB reported significantly worse urinary and sexual function than their counterparts receiving 3DCRT. The mean cumulative IPSS was 12.5 with TIPPB compared to 8.3 with 3DCRT (p=0.036). Differences were most pronounced in the first 12 months after treatment, particularly with respect to the strength of stream and the need to strain. TIPPB patients were more likely to report a need to urinate frequently (p=0.02), require a pad (p=0.001), be bothered (p=0.02), or have activity limited by urinary side effects (p=0.01). TIPPB patients were less likely to resume sexual activity within 6 months after treatment (p=0.0003) and engaged in sexual activity less often (p= 0.016) than 3DCRT patients. They were also more

  8. Doses to organs at cerebral risks: optimization by robotized stereotaxic radiotherapy and automatic segmentation atlas versus three dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Bondiau, P.Y.; Thariat, J.; Benezery, K.; Herault, J.; Dalmasso, C.; Marcie, S.; Malandain, G.

    2007-01-01

    The stereotaxic radiotherapy robotized by 'Cyberknife fourth generation' allows a dosimetric optimization with a high conformity index on the tumor and radiation doses limited on organs at risk. A cerebral automatic anatomic segmentation atlas of organs at risk are used in routine in three dimensions. This study evaluated the superiority of the stereotaxic radiotherapy in comparison with the three dimensional conformal radiotherapy on the preservation of organs at risk in regard of the delivered dose to tumors justifying an accelerated hypo fractionation and a dose escalation. This automatic segmentation atlas should allow to establish correlations between anatomy and cerebral dosimetry; This atlas allows to underline the dosimetry optimization by stereotaxic radiotherapy robotized for organs at risk. (N.C.)

  9. Cost-Effectiveness Analysis of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Anal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hodges, Joseph C., E-mail: joseph.hodges@utsouthwestern.edu [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Beg, Muhammad S. [Division of Hematology and Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Das, Prajnan [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Meyer, Jeffrey [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States)

    2014-07-15

    Purpose: To compare the cost-effectiveness of intensity modulated radiation therapy (IMRT) and 3-dimensional conformal radiation therapy (3D-CRT) for anal cancer and determine disease, patient, and treatment parameters that influence the result. Methods and Materials: A Markov decision model was designed with the various disease states for the base case of a 65-year-old patient with anal cancer treated with either IMRT or 3D-CRT and concurrent chemotherapy. Health states accounting for rates of local failure, colostomy failure, treatment breaks, patient prognosis, acute and late toxicities, and the utility of toxicities were informed by existing literature and analyzed with deterministic and probabilistic sensitivity analysis. Results: In the base case, mean costs and quality-adjusted life expectancy in years (QALY) for IMRT and 3D-CRT were $32,291 (4.81) and $28,444 (4.78), respectively, resulting in an incremental cost-effectiveness ratio of $128,233/QALY for IMRT compared with 3D-CRT. Probabilistic sensitivity analysis found that IMRT was cost-effective in 22%, 47%, and 65% of iterations at willingness-to-pay thresholds of $50,000, $100,000, and $150,000 per QALY, respectively. Conclusions: In our base model, IMRT was a cost-ineffective strategy despite the reduced acute treatment toxicities and their associated costs of management. The model outcome was sensitive to variations in local and colostomy failure rates, as well as patient-reported utilities relating to acute toxicities.

  10. Cost-Effectiveness Analysis of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Anal Cancer

    International Nuclear Information System (INIS)

    Hodges, Joseph C.; Beg, Muhammad S.; Das, Prajnan; Meyer, Jeffrey

    2014-01-01

    Purpose: To compare the cost-effectiveness of intensity modulated radiation therapy (IMRT) and 3-dimensional conformal radiation therapy (3D-CRT) for anal cancer and determine disease, patient, and treatment parameters that influence the result. Methods and Materials: A Markov decision model was designed with the various disease states for the base case of a 65-year-old patient with anal cancer treated with either IMRT or 3D-CRT and concurrent chemotherapy. Health states accounting for rates of local failure, colostomy failure, treatment breaks, patient prognosis, acute and late toxicities, and the utility of toxicities were informed by existing literature and analyzed with deterministic and probabilistic sensitivity analysis. Results: In the base case, mean costs and quality-adjusted life expectancy in years (QALY) for IMRT and 3D-CRT were $32,291 (4.81) and $28,444 (4.78), respectively, resulting in an incremental cost-effectiveness ratio of $128,233/QALY for IMRT compared with 3D-CRT. Probabilistic sensitivity analysis found that IMRT was cost-effective in 22%, 47%, and 65% of iterations at willingness-to-pay thresholds of $50,000, $100,000, and $150,000 per QALY, respectively. Conclusions: In our base model, IMRT was a cost-ineffective strategy despite the reduced acute treatment toxicities and their associated costs of management. The model outcome was sensitive to variations in local and colostomy failure rates, as well as patient-reported utilities relating to acute toxicities

  11. Comparative analysis of dosimetric parameters of three different radiation techniques for patients with Graves’ ophthalmopathy treated with retro-orbital irradiation

    Directory of Open Access Journals (Sweden)

    Lee Victor HF

    2012-11-01

    Full Text Available Abstract Background We would like to investigate the if IMRT produced better target coverage and dose sparing to adjacent normal structures as compared with 3-dimensional conformal radiotherapy (3DCRT and lateral opposing fields (LOF for patients with Graves’ ophthalmopathy treated with retro-orbital irradiation. Methods Ten consecutive patients diagnosed with Graves’ ophthalmopathy were prospectively recruited into this study. An individual IMRT, 3DCRT and LOF plan was created for each patient. Conformity index (CI, homogeneity index (HI and other dosimetric parameters of the targets and organs-at-risk (OAR generated by IMRT were compared with the other two techniques. Results Mann–Whitney U test demonstrated that CI generated by IMRT was superior to that produced by 3DCRT and LOF (p=0.005 for both respectively. Similarly HI with IMRT was proven better than 3DCRT (p=0.007 and LOF (p=0.005. IMRT gave rise to better dose sparing to some OARs including globes, lenses and optic nerves as compared with 3DCRT but not with LOF. Conclusions IMRT, as compared with 3DCRT and LOF, was found to have a better target coverage, conformity and homogeneity and dose sparing to some surrounding structures, despite a slight increase but clinically negligible dose to other structures. Dosimetrically it might be a preferred treatment technique and a longer follow up is warranted to establish its role in routine clinical use.

  12. Potential Benefits of Scanned Intensity-Modulated Proton Therapy Versus Advanced Photon Therapy With Regard to Sparing of the Salivary Glands in Oropharyngeal Cancer

    International Nuclear Information System (INIS)

    Water, Tara A. van de; Lomax, Antony J.; Bijl, Hendrik P.; Jong, Marije E. de; Schilstra, Cornelis; Hug, Eugen B.; Langendijk, Johannes A.

    2011-01-01

    Purpose: To test the hypothesis that scanned intensity-modulated proton therapy (IMPT) results in a significant dose reduction to the parotid and submandibular glands as compared with intensity-modulated radiotherapy with photons (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) for oropharyngeal cancer. In addition, we investigated whether the achieved dose reductions would theoretically translate into a reduction of salivary dysfunction and xerostomia. Methods and Materials: Ten patients with N0 oropharyngeal carcinoma were used. The intensity-modulated plans delivered simultaneously 70 Gy to the boost planning target volume (PTV2) and 54 Gy to the elective nodal areas (PTV1). The 3D-CRT technique delivered sequentially 70 Gy and 46 Gy to PTV2 and PTV1, respectively. Normal tissue complication probabilities were calculated for salivary dysfunction and xerostomia. Results: Planning target volume coverage results were similar for IMPT and IMRT. Intensity-modulated proton therapy clearly improved the conformity. The 3D-CRT results were inferior to these results. The mean dose to the parotid glands by 3D-CRT (50.8 Gy), IMRT (25.5 Gy), and IMPT (16.8 Gy) differed significantly. For the submandibular glands no significant differences between IMRT and IMPT were found. The dose reductions obtained with IMPT theoretically translated into a significant reduction in normal tissue complication probability. Conclusion: Compared with IMRT and 3D-CRT, IMPT improved sparing of the organs at risk, while keeping similar target coverage results. The dose reductions obtained with IMPT vs. IMRT and 3D-CRT varied widely per individual patient. Intensity-modulated proton therapy theoretically translated into a clinical benefit for most cases, but this requires clinical validation.

  13. Incidence of late rectal bleeding in high-dose conformal radiotherapy of prostate cancer using equivalent uniform dose-based and dose-volume-based normal tissue complication probability models

    International Nuclear Information System (INIS)

    Soehn, Matthias; Yan Di; Liang Jian; Meldolesi, Elisa; Vargas, Carlos; Alber, Markus

    2007-01-01

    Purpose: Accurate modeling of rectal complications based on dose-volume histogram (DVH) data are necessary to allow safe dose escalation in radiotherapy of prostate cancer. We applied different equivalent uniform dose (EUD)-based and dose-volume-based normal tissue complication probability (NTCP) models to rectal wall DVHs and follow-up data for 319 prostate cancer patients to identify the dosimetric factors most predictive for Grade ≥ 2 rectal bleeding. Methods and Materials: Data for 319 patients treated at the William Beaumont Hospital with three-dimensional conformal radiotherapy (3D-CRT) under an adaptive radiotherapy protocol were used for this study. The following models were considered: (1) Lyman model and (2) logit-formula with DVH reduced to generalized EUD (3) serial reconstruction unit (RU) model (4) Poisson-EUD model, and (5) mean dose- and (6) cutoff dose-logistic regression model. The parameters and their confidence intervals were determined using maximum likelihood estimation. Results: Of the patients, 51 (16.0%) showed Grade 2 or higher bleeding. As assessed qualitatively and quantitatively, the Lyman- and Logit-EUD, serial RU, and Poisson-EUD model fitted the data very well. Rectal wall mean dose did not correlate to Grade 2 or higher bleeding. For the cutoff dose model, the volume receiving > 73.7 Gy showed most significant correlation to bleeding. However, this model fitted the data more poorly than the EUD-based models. Conclusions: Our study clearly confirms a volume effect for late rectal bleeding. This can be described very well by the EUD-like models, of which the serial RU- and Poisson-EUD model can describe the data with only two parameters. Dose-volume-based cutoff-dose models performed worse

  14. Establishing locoregional control of malignant pleural mesothelioma using high-dose radiotherapy and 18F-FDG PET/CT scan correlation

    International Nuclear Information System (INIS)

    Feigen, Malcolm; Lawford, Catherine; Churcher, Katheryn; Zupan, Eddy; Hamilton, Chris; Lee, Sze Ting; Scott, Andrew M.

    2011-01-01

    The management of malignant pleural mesothelioma represents one of the most challenging issues in oncology, as there is no proven long-term benefit from surgery, radiotherapy or chemotherapy alone or in combination. Locoregional progression remains the major cause of death, but radical surgical resection may produce major postoperative morbidity. While radical or postoperative radiotherapy using conventional techniques has resulted in severe toxicity with no impact on survival, recent advances in radiotherapy delivery may be more effective. We treated patients with locally advanced mesothelioma whose tumours had been sub optimally resected with high-dose three-dimensional conformal radiotherapy (3DCRT) or intensity-modulated radiotherapy (IMRT) to large volumes of one hemithorax, using CT and positron emission tomography (PET) scan-based treatment planning. Clinical outcomes were assessed by determining patterns of failure and metabolic changes in total glycolytic volume (TGV) between pre- and post-irradiation 18 F-FDG PET/CT scans and by recording acute and late toxicity grades. Fourteen patients were analysed with 40 PET scans performed before and up to 4.5 years after radiotherapy. Eleven patients had pleurectomy/decortications, one had an extrapleural pneumonectomy and two had no surgery. Four patients who received chemotherapy had all progressed prior to radiotherapy. After radiotherapy, the in-field local control rate was 71%. No progression occurred in two patients, one was salvaged with further radiotherapy to a new site, four recurred inside the irradiated volume all with concurrent distant metastases and the other seven had distant metastases only. The TGVs were reduced by an average of 67% (range 12–100%) after doses of 45 to 60 Gy to part or all of one hemithorax. There were no serious treatment-related toxicities. Median survival was 25 months from diagnosis and 17 months after starting radiotherapy. We have established that mesothelioma can be

  15. Results of three-dimensional conformal radiotherapy and thalidomide for advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Hsu, Wei-Chung; Chung, Na-Na; Wang, Po-Ming; Ying, Kung-Shih; Shin, Jeng-Shiann; Chao, Che-Jen; Lin, Gau-De; Chan, Sue-Ching; Ting, Lai-Lei

    2006-01-01

    The purpose of this study was to evaluate the effectiveness of three-dimensional conformal radiotherapy and thalidomide in the treatment of advanced hepatocellular carcinoma. Between 1999 and 2003, 121 patients (mean age, 54.4±12.4 years; range, 20-81 years) with advanced hepatocellular carcinoma received three-dimensional conformal radiotherapy and thalidomide. Radiation was delivered in 1.5 Gy fractions twice daily for 5 days a week, for a total dose of 45-75 Gy. Mean treatment volume was 429.52±408.50 cm 3 (range, 26.89-2284.82 cm 3 ). Thalidomide was given concomitantly: 200 mg/day in 109 patients, 300 mg/day in 8 patients and 400 mg/day in 4 patients. Treatment responses, survival rates and factors affecting survival were analyzed. Treatment responses were observed in 61% of the patients. Liver cirrhosis (P=0.001) and tumor size (P=0.001) significantly affected the tumor responses. Overall survival at 6, 12 and 24 months was 84.8, 60.0 and 44.6%, respectively. On univariate analysis, liver cirrhosis (P=0.003), Karnofsky performance status (P=0.007), tumor size (P<0.001), portal vein tumor thrombosis (P<0.001) and alpha-fetoprotein level (P=0.003) were shown to significantly affect survival. On multivariate analysis, only thrombosis (P=0.039) and alpha-fetoprotein level (P=0.006) were shown to be factors affecting survival. Three-dimensional conformal radiotherapy with thalidomide seems to be effective in the treatment of advanced hepatocellular carcinoma. (author)

  16. Conformal three dimensional radiotherapy treatment planning in Lund

    Energy Technology Data Exchange (ETDEWEB)

    Knoos, T; Nilsson, P [Lund Univ. (Sweden). Dept. of Radiation Physics; Anders, A [Lund Univ. (Sweden). Dept. of Oncology

    1995-12-01

    The use of conformal therapy is based on 3-dimensional treatment planning as well as on methods and routines for 3-dimensional patient mapping, 3-dimensional virtual simulation and others. The management of patients at the Radiotherapy Department at the University Hospital in Lund (Sweden) is discussed. About 2100 new patients are annually treated with external radiotherapy using seven linear accelerators. Three of the accelerators have dual photon energies and electron treatment facilities. A multi-leaf collimator as well as an electronic portal imaging device are available on one machine. Two simulators and an in-house CT-scanner are used for treatment planning. From 1988 to 1992 Scandiplan (Umplan) was used. Since 1992, the treatment planning system is TMS (HELAX AB, Sweden), which is based on the pencil beam algorithm of Ahnesjo. The calculations use patient modulated accelerator specific energy fluence spectra which are compiled with pencil beams from Monte Carlo generated energy absorption kernels. Heterogeneity corrections are performed with results close to conventional algorithms. Irregular fields, either from standard or individual blocks and from multi-leaf collimators are handled by the treatment planning system. The field shape is determined conveniently using the beam`s eye view. The final field shape is exported electronically to either the block cutting machine or the multileaf collimator control computer. All patient fields are checked against the beam`s eye view during simulation using manual methods. Treatment verification is performed by portal films and in vivo dosimetry with silicon diodes or TL-dosimetry. Up to now, approximately 4400 patients have received a highly individualized 3-dimensional conformal treatment.

  17. Indications for quality assurance in conformal radiotherapy in Italy

    International Nuclear Information System (INIS)

    Banci Buonamici, F.; DE Angelis, C.; Rosi, A.; Tabocchini, M.A.; Iotti, C.; Olmi, P.

    2008-01-01

    Intensity-Modulated Radiation Therapy (IMRT) is an advanced and promising technique of external beam irradiation. IMRT is able to conform the dose distribution to the 3D tumour shape also for complex geometries, preserving surrounding normal tissues and reducing the probability of side effects. IMRT is a time consuming and complex technique and its use demands high level quality assurance. It is, therefore, very important to define conditions for its utilization. Professionals of Radiotherapy Centres, with experience in the IMRT use, have constituted a multidisciplinary working group with the aim of developing indications in this field. Purpose of the present document is to highlight relevant aspects of the technique, but also to underline the high complexity of the technique, whose implementation requires extreme attention of the staff of Radiotherapy Centres involved [it

  18. Better compliance with hypofractionation vs. conventional fractionation in adjuvant breast cancer radiotherapy. Results of a single, institutional, retrospective study

    International Nuclear Information System (INIS)

    Rudat, Volker; Nour, Alaa; Hammoud, Mohamed; Abou Ghaida, Salam

    2017-01-01

    The aim of the study was to identify factors significantly associated with the occurrence of unintended treatment interruptions in adjuvant breast cancer radiotherapy. Patients treated with postoperative radiotherapy of the breast or chest wall between March 2014 and August 2016 were evaluated. The radiotherapy regimens and techniques applied were either conventional fractionation (CF; 28 daily fractions of 1.8 Gy or 25 fractions of 2.0 Gy) or hypofractionation (HF; 15 daily fractions of 2.67 Gy) with inverse planned intensity-modulated radiotherapy (IMRT) or three-dimensional planned conformal radiotherapy (3DCRT). Logistic regression analysis was used to identify factors associated with noncompliance. Noncompliance was defined as the missing of at least one scheduled radiotherapy fraction. In all, 19 of 140 (13.6%) patients treated with HF and 39 of 146 (26.7%) treated with CF experienced treatment interruptions. Of 23 factors tested, the fractionation regimen emerged as the only independent significant prognostic factor for noncompliance on multivariate analysis (CF; p = 0.007; odds ratio, 2.3; 95% confidence interval, 1.3-4.2). No statistically significant differences concerning the reasons for treatment interruptions could be detected between patients treated with CF or HF. HF is significantly associated with a better patient compliance with the prescribed radiotherapy schedule compared with CF. The data suggest that this finding is basically related to the shorter overall treatment time of HF. (orig.) [de

  19. Predictors of radiation-induced esophageal toxicity in patients with non-small-cell lung cancer treated with three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Singh, Anurag K.; Lockett, Mary Ann; Bradley, Jeffrey D.

    2003-01-01

    Purpose: To evaluate the incidence and clinical/dosimetric predictors of acute and late Radiation Therapy Oncology Group Grade 3-5 esophageal toxicity in patients with non-small-cell lung cancer (NSCLC) treated with definitive three-dimensional conformal radiotherapy (3D-CRT). Methods and Materials: We retrospectively reviewed the charts of 207 consecutive patients with NSCLC who were treated with high-dose, definitive 3D-CRT between March 1991 and December 1998. This population consisted of 107 men and 100 women. The median age was 67 years (range 31-90). The following patient and treatment parameters were studied: age, gender, race, performance status, sequential chemotherapy, concurrent chemotherapy, presence of subcarinal nodes, pretreatment weight loss, mean dose to the entire esophagus, maximal point dose to the esophagus, and percentage of volume of esophagus receiving >55 Gy. All doses are reported without heterogeneity corrections. The median prescription dose to the isocenter in this population was 70 Gy (range 60-74) delivered in 2-Gy daily fractions. All patients were treated once daily. Acute and late esophageal toxicities were graded by Radiation Therapy Oncology Group criteria. Patient and clinical/dosimetric factors were coded and correlated with acute and late Grade 3-5 esophageal toxicity using univariate and multivariate regression analyses. Results: Of 207 patients, 16 (8%) developed acute (10 patients) or late (13 patients) Grade 3-5 esophageal toxicity. Seven patients had both acute and late Grade 3-5 esophageal toxicity. One patient died (Grade 5 esophageal toxicity) of late esophageal perforation. Concurrent chemotherapy, maximal point dose to the esophagus >58 Gy, and a mean dose to the entire esophagus >34 Gy were significantly associated with a risk of Grade 3-5 esophageal toxicity on univariate analysis. Concurrent chemotherapy and maximal point dose to the esophagus >58 Gy retained significance on multivariate analysis. Of 207 patients

  20. High precision conformal radiotherapy employing conservative margins in childhood benign and low-grade brain tumours

    International Nuclear Information System (INIS)

    Jalali, Rakesh; Budrukkar, Ashwini; Sarin, Rajiv; Sharma, Dayananda S.

    2005-01-01

    Background and purpose: To report local control and follow up outcome data of high precision conformal radiotherapy in childhood brain tumours. Materials and methods: Between December 1999 and December 2002, 26 children (17 boys and 9 girls, median age 11.5 years) with incompletely excised or recurrent benign and low-grade brain tumours [13 craniopharyngiomas, 11 low-grade gliomas (LGG) and 2 others] were treated with three-dimensional (3D) conformal radiotherapy (CRT) (12 patients) and stereotactic conformal radiotherapy (SCRT) (14 patients). Gross tumour volume (GTV) included neuro-imaging based visible tumour and/or resected tumour bed. Clinical target volume (CTV) consisted of GTV + 5 mm margin and planning target volume (PTV) consisted of additional 5 mm margin for CRT and 2 mm for SCRT. Treatment was delivered with 3-9 conformal fixed fields to a median dose of 54 Gy/30 fractions. Results: The actuarial 2 and 3 year disease free and overall survival was 96 and 100%, respectively (median follow up: 25 months, range 12-47 months). Radiological follow up available in 25 patients revealed complete response in 1, partial regression in 10, stable disease in 13 and progression in 1 patient (within the CTV). One patient with craniopharyngioma on a routine imaging revealed a mild asymptomatic cyst enlargement, which resolved with conservative management. A patient with chiasmatic glioma developed cystic degeneration and hydrocephalus 9 months after SCRT requiring cyst drainage and placement of a ventriculoperitoneal shunt. Conclusion: High-precision conformal techniques delivering irradiation to a computer generated target volume employing 7-10 mm 3D margins beyond the visible tumour and/or resected tumour bed appear to be safe in children with incompletely resected or recurrent benign and low-grade brain tumours, based on these data

  1. Clinical Studies on conformal radiotherapy combined with epidermal ...

    African Journals Online (AJOL)

    Purpose: To study the effect of conformal radiotherapy combined with epidermal growth factor receptor-tyrosine kinase inhibitor (EGFR-TKI) in the second-line treatment of non-small cell lung cancer (NSCLC). Methods: A total of 316 patients attending Shanghai Pulmonary Hospital affiliated to Tongji University, were divided ...

  2. External beam radiotherapy of localized prostatic adenocarcinoma. Evaluation of conformal therapy, field number and target margins

    International Nuclear Information System (INIS)

    Lennernaes, B.; Rikner, G.; Letocha, H.; Nilsson, S.

    1995-01-01

    The purpose of the present study was to identify factors of importance in the planning of external beam radiotherapy of prostatic adenocarcinoma. Seven patients with urogenital cancers were planned for external radiotherapy of the prostate. Four different techniques were used, viz. a 4-field box technique and four-, five- or six-field conformal therapy set-ups combined with three different margins (1-3 cm). The evaluations were based on the doses delivered to the rectum and the urinary bladder. A normal tissue complication probability (NTCP) was calculated for each plan using Lyman's dose volume reduction method. The most important factors that resulted in a decrease of the dose delivered to the rectum and the bladder were the use of conformal therapy and smaller margins. Conformal therapy seemed more important for the dose distribution in the urinary bladder. Five- and six-field set-ups were not significantly better than those with four fields. NTCP calculations were in accordance with the evaluation of the dose volume histograms. To conclude, four-field conformal therapy utilizing reduced margins improves the dose distribution to the rectum and the urinary bladder in the radiotherapy of prostatic adenocarcinoma. (orig.)

  3. Does the IMRT technique allow improvement of treatment plans (e.g. lung sparing) for lung cancer patients with small lung volume: a planning study

    International Nuclear Information System (INIS)

    Komosinska, K.; Kepka, L.; Gizynska, M.; Zawadzka, A.

    2008-01-01

    Aim: We evaluated whether intensity-modulated radiation therapy (IMRT) may offer any advantages in comparison with three-dimensional conformal radiotherapy (3D-CRT) for patients with small lung volume (SLV). Methods: Treatment planning was performed for 10 NSCLC patients with the smallest lung volume (mean: 2241 cc) among 200 patients from our database. For each patient 3D-CRT and IMRT plans were prepared. The goal was to deliver 66 Gy/33 fractions, with dose constraints: mean lung dose (MLD) < 20 Gy, V20 < 35%; spinal cord - Dmax < 45 Gy. When the plan could not meet these criteria, total dose was reduced. The 3D-CRT and IMRT plans were compared. We investigated: prescribed dose, coverage and conformity indices, MLD, V5-V65 in the lung. Results: In 4 out of 10 plans, 3D-CRT did not allow 66 Gy to be delivered, because of predicted pulmonary toxicity. These 4 cases included 3 for which we did not reach 66 Gy with IMRT; still, for these 3 plans the total dose was increased by an average of 9 Gy with IMRT in comparison with 3D-CRT. Coverage indices were similar for both techniques. Conformity indices were better for IMRT plans. MLD was lower in five IMRT and two 3D-CRT plans if equal doses were delivered. The decrease in MLD was seen for cases with large PTV and high PTV/lung volume ratio. Lung V5 was lower for all 3D-CRT plans, 47% vs. 57% for IMRT; V15 and above were larger for 3D-CRT Conclusion: In the planning study, IMRT seems to be a promising technique for cases with SLV, especially when associated with large PT V. (authors)

  4. Thoracic radiotherapy and breath control: current prospects

    International Nuclear Information System (INIS)

    Reboul, F.; Mineur, L.; Paoli, J.B.; Bodez, V.; Oozeer, R.; Garcia, R.

    2002-01-01

    Three-dimensional conformal radiotherapy (3D CRT) is adversely affected by setup error and organ motion. In thoracic 3D CRT, breathing accounts for most of intra-fraction movements, thus impairing treatment quality. Breath control clearly exhibits dosimetric improvement compared to free breathing, leading to various techniques for gated treatments. We review benefits of different breath control methods -i.e. breath-holding or beam gating, with spirometric, isometric or X-ray respiration sensor- and argument the choice of expiration versus inspiration, with consideration to dosimetric concerns. All steps of 3D-CRT can be improved with breath control. Contouring of organs at risk (OAR) and target are easier and more accurate on breath controlled CT-scans. Inter- and intra-fraction target immobilisation allows smaller margins with better coverage. Lung outcome predictors (NTCP, Mean Dose, LV20, LV30) are improved with breath-control. In addition, inspiration breath control facilitates beam arrangement since it widens the distance between OAR and target, and leaves less lung normal tissue within the high dose region. Last, lung density, as of CT scan, is more accurate, improving dosimetry. Our institutions choice is to use spirometry driven, patient controlled high-inspiration breath-hold; this technique gives excellent immobilization results, with high reproducibility, yet it is easy to implement and costs little extra treatment time. Breath control, whatever technique is employed, proves superior to free breathing treatment when using 3D-CRT. Breath control should then be used whenever possible, and is probably mandatory for IMRT. (authors)

  5. Choosing wisely after publication of level I evidence in breast cancer radiotherapy

    Directory of Open Access Journals (Sweden)

    Niska JR

    2018-02-01

    Full Text Available Joshua R Niska,1 Sameer R Keole,1 Barbara A Pockaj,2 Michele Y Halyard,1 Samir H Patel,1 Donald W Northfelt,3 Richard J Gray,2 Nabil Wasif,2 Carlos E Vargas,1 William W Wong1 1Department of Radiation Oncology, 2Division of General Surgery, 3Division of Hematology and Medical Oncology, Mayo Clinic Hospital, Phoenix, AZ, USA Background: Recent trials in early-stage breast cancer support hypofractionated whole-breast radiotherapy (WBRT as part of breast-conserving therapy (BCT. Evidence also suggests that radiotherapy (RT omission may be reasonable for some patients over 70 years. Among radiation-delivery techniques, intensity-modulated RT (IMRT is more expensive than 3-dimensional conformal RT (3DCRT. Based on this evidence, in 2013, the American Society for Radiation Oncology (ASTRO recommended hypofractionated schedules for women aged ≥50 years with early-stage breast cancer and avoiding routine use of IMRT for WBRT. To assess response to level I evidence and adherence to ASTRO recommendations, we evaluated the pattern of RT use for early-stage breast cancer at our National Comprehensive Cancer Network institution from 2006 to 2008 and 2011 to 2013 and compared the results with national trends. Methods: Data from a prospective database were extracted to include patients treated with BCT, aged ≥50 years, with histologic findings of invasive ductal carcinoma, stage T1-T2N0M0, estrogen receptor-positive, and HER2 normal. We retrospectively reviewed the medical records and estimated costs based on 2016 Hospital Outpatient Prospective Payment System (technical fees and Medicare Physician Fee Schedule (professional fees. Results: Among 55 cases from 2006 to 2008, treatment regimens were 11% hypofractionated, 69% traditional schedule, and 20% RT omission (29% of patients were aged >70 years. Among 83 cases from 2011 to 2013, treatment regimens were 54% hypofractionated, 19% traditional schedule, and 27% RT omission (48% of patients were aged >70

  6. Conventional and conformal technique of external beam radiotherapy in locally advanced cervical cancer: Dose distribution, tumor response, and side effects

    Science.gov (United States)

    Mutrikah, N.; Winarno, H.; Amalia, T.; Djakaria, M.

    2017-08-01

    The objective of this study was to compare conventional and conformal techniques of external beam radiotherapy (EBRT) in terms of the dose distribution, tumor response, and side effects in the treatment of locally advanced cervical cancer patients. A retrospective cohort study was conducted on cervical cancer patients who underwent EBRT before brachytherapy in the Radiotherapy Department of Cipto Mangunkusumo Hospital. The prescribed dose distribution, tumor response, and acute side effects of EBRT using conventional and conformal techniques were investigated. In total, 51 patients who underwent EBRT using conventional techniques (25 cases using Cobalt-60 and 26 cases using a linear accelerator (LINAC)) and 29 patients who underwent EBRT using conformal techniques were included in the study. The distribution of the prescribed dose in the target had an impact on the patient’s final response to EBRT. The complete response rate of patients to conformal techniques was significantly greater (58%) than that of patients to conventional techniques (42%). No severe acute local side effects were seen in any of the patients (Radiation Therapy Oncology Group (RTOG) grades 3-4). The distribution of the dose and volume to the gastrointestinal tract affected the proportion of mild acute side effects (RTOG grades 1-2). The urinary bladder was significantly greater using conventional techniques (Cobalt-60/LINAC) than using conformal techniques at 72% and 78% compared to 28% and 22%, respectively. The use of conformal techniques in pelvic radiation therapy is suggested in radiotherapy centers with CT simulators and 3D Radiotherapy Treatment Planning Systems (RTPSs) to decrease some uncertainties in radiotherapy planning. The use of AP/PA pelvic radiation techniques with Cobalt-60 should be limited in body thicknesses equal to or less than 18 cm. When using conformal techniques, delineation should be applied in the small bowel, as it is considered a critical organ according to RTOG

  7. Optimized Volumetric Modulated Arc Therapy Versus 3D-CRT for Early Stage Mediastinal Hodgkin Lymphoma Without Axillary Involvement: A Comparison of Second Cancers and Heart Disease Risk

    Energy Technology Data Exchange (ETDEWEB)

    Filippi, Andrea Riccardo, E-mail: andreariccardo.filippi@unito.it [Department of Oncology, Radiation Oncology, University of Torino, Torino (Italy); Ragona, Riccardo; Piva, Cristina; Scafa, Davide; Fiandra, Christian [Department of Oncology, Radiation Oncology, University of Torino, Torino (Italy); Fusella, Marco; Giglioli, Francesca Romana [Medical Physics, AOU Città della Salute e della Scienza Hospital, Torino (Italy); Lohr, Frank [Department of Radiation Oncology, University Medical Center Mannheim, University of Heidelberg, Mannheim (Germany); Ricardi, Umberto [Department of Oncology, Radiation Oncology, University of Torino, Torino (Italy)

    2015-05-01

    Purpose: The purpose of this study was to evaluate the risks of second cancers and cardiovascular diseases associated with an optimized volumetric modulated arc therapy (VMAT) planning solution in a selected cohort of stage I/II Hodgkin lymphoma (HL) patients treated with either involved-node or involved-site radiation therapy in comparison with 3-dimensional conformal radiation therapy (3D-CRT). Methods and Materials: Thirty-eight patients (13 males and 25 females) were included. Disease extent was mediastinum alone (n=8, 21.1%); mediastinum plus unilateral neck (n=19, 50%); mediastinum plus bilateral neck (n=11, 29.9%). Prescription dose was 30 Gy in 2-Gy fractions. Only 5 patients had mediastinal bulky disease at diagnosis (13.1%). Anteroposterior 3D-CRT was compared with a multiarc optimized VMAT solution. Lung, breast, and thyroid cancer risks were estimated by calculating a lifetime attributable risk (LAR), with a LAR ratio (LAR{sub VMAT}-to-LAR{sub 3D-CRT}) as a comparative measure. Cardiac toxicity risks were estimated by calculating absolute excess risk (AER). Results: The LAR ratio favored 3D-CRT for lung cancer induction risk in mediastinal alone (P=.004) and mediastinal plus unilateral neck (P=.02) presentations. LAR ratio for breast cancer was lower for VMAT in mediastinal plus bilateral neck presentations (P=.02), without differences for other sites. For thyroid cancer, no significant differences were observed, regardless of anatomical presentation. A significantly lower AER of cardiac (P=.038) and valvular diseases (P<.0001) was observed for VMAT regardless of disease extent. Conclusions: In a cohort of patients with favorable characteristics in terms of disease extent at diagnosis (large prevalence of nonbulky presentations without axillary involvement), optimized VMAT reduced heart disease risk with comparable risks of thyroid and breast cancer, with an increase in lung cancer induction probability. The results are however strongly influenced by

  8. Transitioning from conventional radiotherapy to intensity-modulated radiotherapy for localized prostate cancer. Changing focus from rectal bleeding to detailed quality of life analysis

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Nakamura, Satoaki; Nishimura, Takuya; Yoshida, Ken; Yoshioka, Yasuo; Koizumi, Masahiko; Ogawa, Kazuhiko

    2014-01-01

    With the advent of modern radiation techniques, we have been able to deliver a higher prescribed radiotherapy dose for localized prostate cancer without severe adverse reactions. We reviewed and analyzed the change of toxicity profiles of external beam radiation therapy (EBRT) from the literature. Late rectal bleeding is the main adverse effect, and an incidence of >20% of Grade ≥2 adverse events was reported for 2D conventional radiotherapy of up to 70 Gy. 3D conformal radiation therapy (3D-CRT) was found to reduce the incidence to ∼10%. Furthermore, intensity-modulated radiation therapy (IMRT) reduced it further to a few percentage points. However, simultaneously, urological toxicities were enhanced by dose escalation using highly precise external radiotherapy. We should pay more attention to detailed quality of life (QOL) analysis, not only with respect to rectal bleeding but also other specific symptoms (such as urinary incontinence and impotence), for two reasons: (1) because of the increasing number of patients aged >80 years, and (2) because of improved survival with elevated doses of radiotherapy and/or hormonal therapy; age is an important prognostic factor not only for prostate-specific antigen (PSA) control but also for adverse reactions. Those factors shift the main focus of treatment purpose from survival and avoidance of PSA failure to maintaining good QOL, particularly in older patients. In conclusion, the focus of toxicity analysis after radiotherapy for prostate cancer patients is changing from rectal bleeding to total elaborate quality of life assessment. (author)

  9. Cost-Effectiveness Analysis of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Preoperative Treatment of Extremity Soft Tissue Sarcomas

    Energy Technology Data Exchange (ETDEWEB)

    Richard, Patrick, E-mail: patrjr@uw.edu [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Phillips, Mark; Smith, Wade [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Davidson, Darin [Department of Orthopedic Surgery, University of Washington, Seattle, Washington (United States); Kim, Edward; Kane, Gabrielle [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States)

    2016-07-01

    Purpose: Create a cost-effectiveness model comparing preoperative intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3DCRT) for extremity soft tissue sarcomas. Methods and Materials: Input parameters included 5-year local recurrence rates, rates of acute wound adverse events, and chronic toxicities (edema, fracture, joint stiffness, and fibrosis). Health-state utilities were used to calculate quality-adjusted life years (QALYs). Overall treatment costs per QALY or incremental cost-effectiveness ratio (ICER) were calculated. Roll-back analysis was performed using average costs and utilities to determine the baseline preferred radiation technique. One-way, 2-way, and probabilistic sensitivity analyses (PSA) were performed for input parameters with the largest impact on the ICER. Results: Overall treatment costs were $17,515.58 for 3DCRT compared with $22,920.51 for IMRT. The effectiveness was higher for IMRT (3.68 QALYs) than for 3DCRT (3.35 QALYs). The baseline ICER for IMRT was $16,842.75/QALY, making it the preferable treatment. The ICER was most sensitive to the probability of local recurrence, upfront radiation costs, local recurrence costs, certain utilities (no toxicity/no recurrence, grade 1 toxicity/no local recurrence, grade 4 toxicity/no local recurrence), and life expectancy. Dominance patterns emerged when the cost of 3DCRT exceeded $15,532.05 (IMRT dominates) or the life expectancy was under 1.68 years (3DCRT dominates). Furthermore, preference patterns changed based on the rate of local recurrence (threshold: 13%). The PSA results demonstrated that IMRT was the preferred cost-effective technique for 64% of trials compared with 36% for 3DCRT. Conclusions: Based on our model, IMRT is the preferred technique by lowering rates of local recurrence, severe toxicities, and improving QALYs. From a third-party payer perspective, IMRT should be a supported approach for extremity soft tissue sarcomas.

  10. Cost-Effectiveness Analysis of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Preoperative Treatment of Extremity Soft Tissue Sarcomas

    International Nuclear Information System (INIS)

    Richard, Patrick; Phillips, Mark; Smith, Wade; Davidson, Darin; Kim, Edward; Kane, Gabrielle

    2016-01-01

    Purpose: Create a cost-effectiveness model comparing preoperative intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3DCRT) for extremity soft tissue sarcomas. Methods and Materials: Input parameters included 5-year local recurrence rates, rates of acute wound adverse events, and chronic toxicities (edema, fracture, joint stiffness, and fibrosis). Health-state utilities were used to calculate quality-adjusted life years (QALYs). Overall treatment costs per QALY or incremental cost-effectiveness ratio (ICER) were calculated. Roll-back analysis was performed using average costs and utilities to determine the baseline preferred radiation technique. One-way, 2-way, and probabilistic sensitivity analyses (PSA) were performed for input parameters with the largest impact on the ICER. Results: Overall treatment costs were $17,515.58 for 3DCRT compared with $22,920.51 for IMRT. The effectiveness was higher for IMRT (3.68 QALYs) than for 3DCRT (3.35 QALYs). The baseline ICER for IMRT was $16,842.75/QALY, making it the preferable treatment. The ICER was most sensitive to the probability of local recurrence, upfront radiation costs, local recurrence costs, certain utilities (no toxicity/no recurrence, grade 1 toxicity/no local recurrence, grade 4 toxicity/no local recurrence), and life expectancy. Dominance patterns emerged when the cost of 3DCRT exceeded $15,532.05 (IMRT dominates) or the life expectancy was under 1.68 years (3DCRT dominates). Furthermore, preference patterns changed based on the rate of local recurrence (threshold: 13%). The PSA results demonstrated that IMRT was the preferred cost-effective technique for 64% of trials compared with 36% for 3DCRT. Conclusions: Based on our model, IMRT is the preferred technique by lowering rates of local recurrence, severe toxicities, and improving QALYs. From a third-party payer perspective, IMRT should be a supported approach for extremity soft tissue sarcomas.

  11. Propensity Score Matching Analysis of Changes in Alpha-Fetoprotein Levels after Combined Radiotherapy and Transarterial Chemoembolization for Hepatocellular Carcinoma with Portal Vein Tumor Thrombus.

    Directory of Open Access Journals (Sweden)

    Yuri Jeong

    Full Text Available To investigate the value of changes in alpha-fetoprotein (AFP levels for the prediction of radiologic response and survival outcomes in hepatocellular carcinoma (HCC patients with portal vein tumor thrombus (PVTT who received combined treatment of 3-dimensional conformal radiotherapy (3D-CRT and transarterial chemoembolization (TACE.A database of 154 HCC patients with PVTT and elevated AFP levels (>20 ng/mL treated with 3D-CRT and TACE as an initial treatment between August 2002 and August 2008 was retrospectively reviewed. AFP levels were determined 1 month after radiotherapy, and AFP response was defined as an AFP level reduction of >20% from the initial level. Radiologic response, overall survival (OS, and progression-free survival (PFS rates were compared between AFP responders and non-responders. Propensity-score based matching analysis was performed to minimize the effect of potential confounding bias.The median follow-up period was 11.1 months (range, 3.1-82.7 months. In the propensity-score matching cohort (92 pairs, a best radiologic response of CR or PR occurred in more AFP responders than AFP non-responders (41.3% vs. 10.9%, p < 0.001. OS and PFS were also longer in AFP responders than in non-responders (median OS 13.2 months vs. 5.6 months, p < 0.001; median PFS 8.7 months vs. 3.5 months, p < 0.001.AFP response is a significant predictive factor for radiologic response. Furthermore, AFP response is significant for OS and PFS outcomes. AFP evaluation after combined radiotherapy and TACE appears to be a useful predictor of clinical outcomes in HCC patients with PVTT.

  12. Comparison between conventional and three-dimensional conformal treatment planning for radiotherapy of cerebral tumors

    International Nuclear Information System (INIS)

    Caudrelier, J.M.; Auliard, A.; Sarrazin, T.; Gibon, D.; Coche-Dequeant, B.; Castelain, B.

    2001-01-01

    Comparison between conventional and three-dimensional conformal treatment planning for radiotherapy of cerebral tumors. Purpose. - We prospectively compared a conventional treatment planning (PT2D) and 3-dimensional conformal treatment planning (PT3D) for radiotherapy of cerebral tumours. Patients and methods.- Patients treated between 1/10/98 and 1/4/99 by irradiation for cerebral tumours were analysed. For each case, we planned PT2D using conventional orthogonal x-ray films, and afterward, PT3D using CT scan. Gross tumor volume, planning target volume and normal tissue volumes were defined. Dose was prescribed according to report 50 of the International Commission on Radiation Units and Measurements (ICRU). We compared surfaces of sagittal view targets defined on PT2D and PT3D and called them S2D and S3D, respectively. Irradiated volumes by 90% isodoses (VE-90%) and normal tissue volumes irradiated by 20, 50, 90% isodoses were calculated and compared using Student's paired t-test. Results. -There was a concordance of 84% of target surfaces defined on PT2D and PT3D. Percentages of target surface under- or-over defined by PT2D were 16 and 13% respectively. VE-90% was decreased by 15% (p = 0.07) with PT3D. Normal brain volume irradiated by 90% isodose was decreased by 27% with PT3D (p = 0.04). Conclusion.- For radiotherapy of cerebral tumors using only coplanar beams, PT3D leads to a reduction of normal brain tissue irradiated. We recommend PT3D for radiotherapy of cerebral tumors, particularly for low-grade or benign tumors (meningiomas, neuromas, etc.). (authors)

  13. Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine

    International Nuclear Information System (INIS)

    Bannach, B.; Doll, Th.; Pape, H.; Schmitt, G.

    1995-01-01

    The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) results in MLC-field-shaping concerning size, position and contour to PTV-projection in beams-eye-view (BEV). Field prescription with defined leaf positions of the MLC-setting for geometrical beam shaping is transferred from TPS via TCP/IP. Patient treatment with complex coplanar and non-coplanar field arrangements is performed with an automatic set-up for gantry and collimator angle position contolled by a verification system. Quality assurance for treatment set-up is gained with a mega-voltage imaging device (MVI / PHILIPS SRI 100). Actual treatment outcome and accurate dose delivery for conformal therapy is verified by intercomparison of geometrical field matching of MVI and digitally reconstructed radiographs (DRR) for each delivered beam in BEV

  14. A computer-controlled conformal radiotherapy system I: overview

    International Nuclear Information System (INIS)

    Fraass, Benedick A.; McShan, Daniel L.; Kessler, Marc L.; Matrone, Gwynne M.; Lewis, James D.; Weaver, Tamar A.

    1995-01-01

    Purpose: Equipment developed for use with computer-controlled conformal radiotherapy (CCRT) treatment techniques, including multileaf collimators and/or computer-control systems for treatment machines, are now available. The purpose of this work is to develop a system that will allow the safe, efficient, and accurate delivery of CCRT treatments as routine clinical treatments, and permit modifications of the system so that the delivery process can be optimized. Methods and Materials: The needs and requirements for a system that can fully support modern computer-controlled treatment machines equipped with multileaf collimators and segmental or dynamic conformal therapy capabilities have been analyzed and evaluated. This analysis has been used to design and then implement a complete approach to the delivery of CCRT treatments. Results: The computer-controlled conformal radiotherapy system (CCRS) described here consists of a process for the delivery of CCRT treatments, and a complex software system that implements the treatment process. The CCRS system described here includes systems for plan transfer, treatment delivery planning, sequencing of the actual treatment delivery process, graphical simulation and verification tools, as well as an electronic chart that is an integral part of the system. The CCRS system has been implemented for use with a number of different treatment machines. The system has been used clinically for more than 2 years to perform CCRT treatments for more than 200 patients. Conclusions: A comprehensive system for the implementation and delivery of computer-controlled conformal radiation therapy (CCRT) plans has been designed and implemented for routine clinical use with multisegment, computer-controlled, multileaf-collimated conformal therapy. The CCRS system has been successfully implemented to perform these complex treatments, and is considered quite important to the clinical use of modern computer-controlled treatment techniques

  15. An ill-conditioning conformal radiotherapy analysis based on singular values decomposition

    International Nuclear Information System (INIS)

    Lefkopoulos, D.; Grandjean, P.; Bendada, S.; Dominique, C.; Platoni, K.; Schlienger, M.

    1995-01-01

    Clinical experience in stereotactic radiotherapy of irregular complex lesions had shown that optimization algorithms were necessary to improve the dose distribution. We have developed a general optimization procedure which can be applied to different conformal irradiation techniques. In this presentation this procedure is tested on the stereotactic radiotherapy modality of complex cerebral lesions treated with multi-isocentric technique based on the 'associated targets methodology'. In this inverse procedure we use the singular value decomposition (SVD) analysis which proposes several optimal solutions for the narrow beams weights of each isocentre. The SVD analysis quantifies the ill-conditioning of the dosimetric calculation of the stereotactic irradiation, using the condition number which is the ratio of the bigger to smaller singular values. Our dose distribution optimization approach consists on the study of the irradiation parameters influence on the stereotactic radiotherapy inverse problem. The adjustment of the different irradiation parameters into the 'SVD optimizer' procedure is realized taking into account the ratio of the quality reconstruction to the time calculation. It will permit a more efficient use of the 'SVD optimizer' in clinical applications for real 3D lesions. The evaluation criteria for the choice of satisfactory solutions are based on the dose-volume histograms and clinical considerations. We will present the efficiency of ''SVD optimizer'' to analyze and predict the ill-conditioning in stereotactic radiotherapy and to recognize the topography of the different beams in order to create optimal reconstructed weighting vector. The planification of stereotactic treatments using the ''SVD optimizer'' is examined for mono-isocentrically and complex dual-isocentrically treated lesions. The application of the SVD optimization technique provides conformal dose distribution for complex intracranial lesions. It is a general optimization procedure

  16. Association of anorectal dose-volume histograms and impaired fecal continence after 3D conformal radiotherapy for carcinoma of the prostate

    International Nuclear Information System (INIS)

    Vordermark, Dirk; Schwab, Michael; Ness-Dourdoumas, Rhea; Sailer, Marco; Flentje, Michael; Koelbl, Oliver

    2003-01-01

    Purpose: The late toxicity of fecal incontinence after pelvic radiotherapy is now frequently recognized but the etiology poorly understood. We therefore investigated associations between dose-volume histogram (DVH) parameters of the rectum and the anal canal with fecal continence as measured by an established 10-item questionnaire. Methods and materials: Forty-four patients treated for carcinoma of the prostate with 58-72 Gy of 3D conformal radiotherapy between 1995 and 1999 who completed the questionnaire formed the study population. Total continence scores of treated patients obtained 1.5 years (median) after radiotherapy were compared to a control group of 30 patients before radiotherapy. Median, mean, minimum and maximum doses as well as the volume (% and ml) treated to 40, 50, 60 and 70 Gy were determined separately for anal canal and rectum. DVH parameters were correlated with total continence score (Spearman rank test) and patients grouped according to observed continence were compared regarding DVH values (Mann-Whitney U-test). Results: Median fecal continence scores were significantly worse in the irradiated than in the control group (31 vs. 35 of a maximum 36 points). In treated patients, 59%/27%/14% were classified as fully continent, slightly incontinent and severely incontinent. Continence was similar in the 58-to-62-Gy, 66-Gy and 68-to-72-Gy dose groups. No DVH parameter was significantly correlated with total continence score, but severely incontinent patients had a significantly higher minimum dose to the anal canal than fully continent/slightly incontinent, accompanied by portals extending significantly further inferiorly with respect to the ischial tuberosities. Conclusions: Excluding the inferior part of the anal canal from the treated volume in 3D conformal therapy for carcinoma of the prostate appears to be a promising strategy to prevent radiation-induced fecal incontinence

  17. Three dimensional conformal radiation therapy may improve the therapeutic ratio of radiation therapy after pneumonectomy for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Trouette, R; Causse, N; Elkhadri, M; Caudry, M; Maire, J P; Houlard, J P; Racaldini, L; Demeaux, H

    1995-12-01

    Three dimensional conformal radiation therapy would allow to decrease the normal tissue dose while maintaining the same target dose as standard treatment. To evaluate the feasibility of normal tissue dose reduction for ten patients with pneumonectomy for lung cancer, we determined the dose distribution to the normal tissue with 3-dimensional conformal radiation therapy (3-DCRT) and conventional treatment planning (CTP). Dose-volume histograms for target and normal tissue (lung, heart) were used for comparison of the different treatment planning. The mean percentages of lung and heart volumes which received 40 Gy with 3-DCRT were respectively 63% and 37% of the mean percentage of lung and volumes which received the same dose with CTP. These preliminary results suggest that conformal therapy may improve the therapeutic ratio by reducing risk to normal tissue.

  18. Parotid gland-recovery after radiotherapy in the head and neck region - 36 months follow-up of a prospective clinical study

    Science.gov (United States)

    2011-01-01

    Background The aim of the present study was to evaluate the recovery potential of the parotid glands after using either 3D-conformal-radiotherapy (3D-CRT) or intensity-modulated radiotherapy (IMRT) by sparing one single parotid gland. Methods Between 06/2002 and 10/2008, 117 patients with head and neck cancer were included in this prospective, non-randomised clinical study. All patients were treated with curative intent. Salivary gland function was assessed by measuring stimulated salivary flow at the beginning, during and at the end of radiotherapy as well as 1, 6, 12, 24, and 36 months after treatment. Measurements were converted to flow rates and normalized relative to rates before treatment. Mean doses (Dmean) were calculated from dose-volume histograms based on computed tomographies of the parotid glands. Results Patients were grouped according to the Dmean of the spared parotid gland having the lowest radiation exposure: Group I - Dmean 40 Gy (n = 36). 15/117 (13%) patients received IMRT. By using IMRT as compared to 3D-CRT the Dmean of the spared parotid gland could be significantly reduced (Dmean IMRT vs. 3D-CRT: 21.7 vs. 34.4 Gy, p < 0.001). The relative salivary flow rates (RFSR) as a function of the mean parotid dose after 24 and 36 months was in group I 66% and 74%, in group II 56% and 49%, and in group III 31% and 24%, respectively. Multiple linear regression analyses revealed that the parotid gland dose and the tumor site were the independent determinants 12 and 36 months after the end of RT. Patients of group I and II parotid gland function did recover at 12, 24, and 36 months after the end of RT. Conclusions If a Dmean < 26 Gy for at least one parotid gland can be achieved then this is sufficient to reach complete recovery of pre-RT salivary flow rates. The radiation volume which depends on tumor site did significantly impact on the Dmean of the parotids, and thus on the saliva flow and recovery of parotid gland. PMID:21951317

  19. Parotid gland-recovery after radiotherapy in the head and neck region - 36 months follow-up of a prospective clinical study

    International Nuclear Information System (INIS)

    Hey, Jeremias; Setz, Juergen; Gerlach, Reinhard; Janich, Martin; Hildebrandt, Guido; Vordermark, Dirk; Gernhardt, Christian R; Kuhnt, Thomas

    2011-01-01

    The aim of the present study was to evaluate the recovery potential of the parotid glands after using either 3D-conformal-radiotherapy (3D-CRT) or intensity-modulated radiotherapy (IMRT) by sparing one single parotid gland. Between 06/2002 and 10/2008, 117 patients with head and neck cancer were included in this prospective, non-randomised clinical study. All patients were treated with curative intent. Salivary gland function was assessed by measuring stimulated salivary flow at the beginning, during and at the end of radiotherapy as well as 1, 6, 12, 24, and 36 months after treatment. Measurements were converted to flow rates and normalized relative to rates before treatment. Mean doses (D mean ) were calculated from dose-volume histograms based on computed tomographies of the parotid glands. Patients were grouped according to the D mean of the spared parotid gland having the lowest radiation exposure: Group I - D mean < 26 Gy (n = 36), group II - D mean 26-40 Gy (n = 45), and group III - D mean > 40 Gy (n = 36). 15/117 (13%) patients received IMRT. By using IMRT as compared to 3D-CRT the D mean of the spared parotid gland could be significantly reduced (D mean IMRT vs. 3D-CRT: 21.7 vs. 34.4 Gy, p < 0.001). The relative salivary flow rates (RFSR) as a function of the mean parotid dose after 24 and 36 months was in group I 66% and 74%, in group II 56% and 49%, and in group III 31% and 24%, respectively. Multiple linear regression analyses revealed that the parotid gland dose and the tumor site were the independent determinants 12 and 36 months after the end of RT. Patients of group I and II parotid gland function did recover at 12, 24, and 36 months after the end of RT. If a D mean < 26 Gy for at least one parotid gland can be achieved then this is sufficient to reach complete recovery of pre-RT salivary flow rates. The radiation volume which depends on tumor site did significantly impact on the D mean of the parotids, and thus on the saliva flow and recovery of

  20. Quality assurance of 3-D conformal radiation therapy for a cooperative group trial - RTOG 3D QA center initial experience

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Purdy, James A.; Harms, William B.; Bosch, Walter R.; Oehmke, Frederick; Cox, James D.

    1996-01-01

    PURPOSE: 3-D conformal radiation therapy (3DCRT) holds promise in allowing safe escalation of radiation dose to increase the local control of prostate cancer. Prospective evaluation of this new modality requires strict quality assurance (QA). We report the results of QA review on patients receiving 3DCRT for prostate cancer on a cooperative group trial. MATERIALS and METHODS: In 1993 the NCI awarded the ACR/RTOG and nine institutions an RFA grant to study the use of 3DCRT in the treatment of prostate cancer. A phase I/II trial was developed to: a) test the feasibility of conducting 3DCRT radiation dose escalation in a cooperative group setting; b) establish the maximum tolerated radiation dose that can be delivered to the prostate; and c) quantify the normal tissue toxicity rate when using 3DCRT. In order to assure protocol compliance each participating institution was required to implement data exchange capabilities with the RTOG 3D QA center. The QA center reviews at a minimum the first five case from each participating center and spot checks subsequent submissions. For each case review the following parameters are evaluated: 1) target volume delineation, 2) normal structure delineation, 3) CT data quality, 4) field placement, 5) field shaping, and 6) dose distribution. RESULTS: Since the first patient was registered on August 23, 1994, an additional 170 patients have been accrued. Each of the nine original approved institutions has participated and three other centers have recently passed quality assurance bench marks for study participation. Eighty patients have been treated at the first dose level (68.4 Gy minimum PTV dose) and accrual is currently ongoing at the second dose level (73.8 Gy minimum PTV dose). Of the 124 cases that have undergone complete or partial QA review, 30 cases (24%) have had some problems with data exchange. Five of 67 CT scans were not acquired by protocol standards. Target volume delineation required the submitting institution

  1. CONSERVATIVE TREATMENT IN LOCALLY AND LOCALLY-ADVANCED PROSTATE CANCER USING CONFORMAL RADIOTHERAPY

    Directory of Open Access Journals (Sweden)

    Tkachev Sergey Ivanovich

    2013-01-01

    Full Text Available The combination of androgen deprivation and radiotherapy increase the probability of diseases full regresses and survival rate. Modern technical and technological opportunities of 3D CRT allow to increase total dose to prostate up to 72-76Gy vs. radiotherapy of 66-70Gy. In this study we compare the rates of post radiation toxicity and the efficiency of treatment for the patients receiving conventional radiotherapy and 3D CRT. The use of 3D CRT has not only result to increase of 10-years recurrence free survival rate from 74% (I grope to 86,5% (II grope, р=0,01, but also to increase of 10-years overall survival, 70% versus 78,4% (р=0,04. The proposed version of conformal 3D CRT radiation therapy made ​​it possible compared to conventional 2D RT radiation therapy by increasing SOD radiation to the tumor, accuracy and compliance with the quality assurance of radiation therapy significantly reduce rates of recurrence and significantly increase the performance of 10-year overall and disease-free survival.

  2. Geometric accuracy of field alignment in fractionated stereotactic conformal radiotherapy of brain tumors

    International Nuclear Information System (INIS)

    Kortmann, Rolf D.; Becker, Gerd; Perelmouter, Jury; Buchgeister, Markus; Meisner, Christoph; Bamberg, Michael

    1999-01-01

    Purpose: To assess the accuracy of field alignment in patients undergoing three-dimensional (3D) conformal radiotherapy of brain tumors, and to evaluate the impact on the definition of planning target volume and control procedures. Methods and Materials: Geometric accuracy was analyzed in 20 patients undergoing fractionated stereotactic conformal radiotherapy for brain tumors. Rigid head fixation was achieved by using cast material. Transfer of stereotactic coordinates was performed by an external positioning device. The accuracy during treatment planning was quantitatively assessed by using repeated computed tomography (CT) examinations in treatment position (reproducibility of isocenter). Linear discrepancies were measured between treatment plan and CT examination. In addition, for each patient, a series of 20 verifications were taken in orthogonal projections. Linear discrepancies were measured between first and all subsequent verifications (accuracy during treatment delivery). Results: For the total group of patients, the distribution of deviations during treatment setup showed mean values between -0.3-1.2 mm, with standard deviations (SD) of 1.3-2.0 mm. During treatment delivery, the distribution of deviations revealed mean values between 0.7-0.8 mm, with SDs of 0.5-0.6 mm, respectively. For all patients, deviations for the transition to the treatment machine were similar to deviations during subsequent treatment delivery, with 95% of all absolute deviations between less than 2.8 and 4.6 mm. Conclusion: Random fluctuations of field displacements during treatment planning and delivery prevail. Therefore, our quantitative data should be considered when prescribing the safety margins of the planning target volume. Repeated CT examination are useful to detect operator errors and large random or systematic deviations before start of treatment. Control procedures during treatment delivery appear to be of limited importance. In addition, our findings should help to

  3. Predictive parameters for selection of electronic tissue compensation radiotherapy in early-stage breast cancer patients after breast-conserving surgery.

    Science.gov (United States)

    Song, Yanbo; Zhang, Miao; Gan, Lu; Chen, Xiaopin; Zhang, Tao; Yue, Ning J; Goyal, Sharad; Haffty, Bruce; Ren, Guosheng

    2016-05-31

    Electronic tissue compensation (eComp) is an external beam planning technique allowing user to manually generate dynamic beam fluence to produce more uniform or modulated dose distribution. In this study, we compared the effectiveness between conventional three-dimensional conformal radiotherapy (3DCRT) and eComp for whole breast irradiation. 3DCRT and eComp planning techniques were used to generate treatment plans for 60 whole breast patients, respectively. The planning goal was to cover 95% of the planning target volume (PTV) with 95% of the prescription dose while minimizing doses to lung, heart, and skin. Comparing to 3DCRT plans, on the average, eComp treatment planning process was about 7 minutes longer, but resulted in lower lung V20Gy, lower mean skin dose, with similar heart dose. The benefits were more pronounced for larger breast patients. Statistical analyses were performed between critical organ doses and patient anatomic features, i.e., central lung distance (CLD), maximal heart distance (MHD), maximal heart length (MHL) and breast separation (BS) to explore any correlations and planning method selection. It was found that to keep the lung V20Gy lower than 20% and mean skin dose lower than 85% of the prescription dose, eComp was the preferred method for patients with more than 2.3 cm CLD or larger than 22.5 cm BS. The study results may be useful in providing a handy criterion in clinical practice allowing us to easily choose between different planning techniques to satisfy the planning goal with minimal increase in complexity and cost.

  4. Impact of Volumetric Modulated Arc Therapy Technique on Treatment With Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Qiu Jianjian; Chang Zheng; Wu, Q. Jackie; Yoo, Sua; Horton, Janet; Yin Fangfang

    2010-01-01

    Purpose: To investigate the technical feasibility of volumetric modulated arc therapy (V-MAT) in the delivery of partial breast irradiation (PBI). Methods and Materials: V-MAT and the standard, three-dimensional conformal radiotherapy (3D-CRT), were compared retrospectively in 8 patients previously treated with PBI. These patients' plans were replanned with a single partial arc using V-MAT that included partial blocking to minimize normal tissue dose. Dosimetric parameters were calculated to evaluate plan quality. Quality assurance studies included verifying both the point and the multiple planar doses. Total monitor units and delivery time were also evaluated, and collision clearance was analyzed. Results: Volumes of ipsilateral lung irradiated to 10 Gy (V10) and 20 Gy (V20) by V-MAT were significantly less than those of 3D-CRT (p = 0.03 for V10 and p = 0.025 for V20). The volume of ipsilateral breast irradiated to 5 Gy was significantly less by using V-MAT than with 3D-CRT (p = 0.02), with a ratio of integrated dose of <1.00. The total mean monitor units (489 ± 38) for V-MAT were significantly less than those for 3D-CRT (634 ± 123) (p = 0.017), with a 23% reduction. The average machine delivery time was 1.21 ± 0.10 min for the V-MAT plans and 6.28 ± 1.40 min for the 3D-CRT plans, resulting in a reduction factor of 80.1%. The conformity indexes were 1.3 in the V-MAT plans and 1.5 in the 3D-CRT plans (p = 0.102). Conclusions: V-MAT technology is feasible for PBI patients. Compared to a conventional 3D-CRT technique, it is more efficient, offers equivalent or better dose conformity, delivers lower doses to the ipsilateral lung and breast, and may potentially reduce intrafractional motion.

  5. A national survey of supportive practices for patients undergoing radiotherapy for oral cancers

    International Nuclear Information System (INIS)

    Osborn, Joanne; Doolan, Caroline

    2013-01-01

    Purpose: Xerostomia and mucositis are two of the main radiation induced toxicities experienced by patients undergoing radiotherapy to the oral cavity. These toxicities can lead to significant weight loss with the potential to cause complications with radiotherapy treatment. Literature has shown that nutritional intervention can help to minimise these side effects. The aim of the survey was to explore current practice across the UK in nutritional intervention for these patients. Method: Postal questionnaires were sent to all 63 radiotherapy departments in the UK in November 2009. Results: 29 responses (43%) were received. 90% (n = 26) of the departments used 3D-Conformal radiotherapy (3D-CRT) as the main technique for treatment of these patients, with 48% (n = 14) of departments having implemented Intensity modulated radiotherapy (IMRT). All departments referred their patients to a dietician. 93% (n = 27) of departments placed percutaneous endoscopic gastrostomy or radiologically-inserted gastrostomy tubes. 55% (n = 16) departments administered nasogastric tubes. Conclusion: This survey verified many common practices regarding dietary care and advice, some variation was evident in the use of feeding tubes. All responding centres referred patients to a dietician with the aim to maintain nutritional status and prevent weight loss that could contribute to uncertainty in treatment setup. This survey also demonstrated that since Macknelly and Day's (2009) study, a greater number of centres have implemented IMRT for patients undergoing radiotherapy to the head and neck. Although IMRT has been shown to reduce xerostomia, this audit found no changes in the dietary care and advice given to these patients

  6. Reduction of xerostomia in head and neck cancer patients. A critical review of the literature

    International Nuclear Information System (INIS)

    Hanley, O.; Leech, M.

    2016-01-01

    Background: Radical radiotherapy given with or without concurrent chemotherapy is the main treatment modality in non-surgical patients for the management of squamous cell carcinoma in the head and neck. Xerostomia, which results from reduced salivary production is a debilitating side-effect of radiation therapy to these patients. Xerostomia may greatly impact on quality of life for head and neck cancer patients for up to 24 months post-radiation therapy. Such effects include difficulties in fundamental daily activities such as speech, mastication and swallowing. It is believed that modulated techniques provide better sparing to surrounding salivary glands. The aim of this critical review of the literature is to investigate what advantage intensity modulated radiotherapy (IMRT) can provide over 3 dimensional conformal radiation therapy (3DCRT) in reducing xerostomia in this subset of patients. Search methodology: An extensive literature search was undertaken to compare the incidence of grade 2 or worse xerostomia in HNSCC patients treated with IMRT or 3DCRT (±chemotherapy). Results: Studies reported a lower incidence of grade 2 or worse xerostomia with IMRT over patients treated with 3DCRT. The highest incidence of xerostomia was reported at 6 months following the completion of radiotherapy treatment. The incidence of xerostomia in patients declined with time, in both patients treated with IMRT and those of the 3DCRT cohort. The incidence of xerostomia was greater in the acute setting than in the late. Conclusion: An IMRT technique can consistently reduce grade 2 or worse xerostomia in head and neck cancer patients over conformal techniques. This will not compromise dose homogeneity or dose coverage. IMRT should remain the standard of care for head and neck patients. - Highlights: • IMRT technique can consistently reduce grade 2 or worse xerostomia in head and neck cancer patients over 3DCRT. • IMRT does not compromise the treatment's dose homogeneity or

  7. Conformal fields in prostate radiotherapy: A comparison between measurement, calculation and simulation

    Directory of Open Access Journals (Sweden)

    Seied R Mahdavi

    2012-01-01

    Full Text Available Aims: The objective of this study is to evaluate the accuracy of a treatment planning system (TPS for calculating the dose distribution parameters in conformal fields (CF. Dosimetric parameters of CF′s were compared between measurement, Monte Carlo simulation (MCNP4C and TPS calculation. Materials and Methods: Field analyzer water phantom was used for obtaining percentage depth dose (PDD curves and beam profiles (BP of different conformal fields. MCNP4C was used to model conformal fields dose specification factors and head of linear accelerator varian model 2100C/D. Results: Results showed that the distance to agreement (DTA and dose difference (DD of our findings were well within the acceptance criteria of 3 mm and 3%, respectively. Conclusions: According to this study it can be revealed that TPS using equivalent tissue air ratio calculation method is still convenient for dose prediction in non small conformal fields normally used in prostate radiotherapy. It was also showed that, since there is a close correlation with Monte Carlo simulation, measurements and TPS, Monte Carlo can be further confirmed for implementation and calculation dose distribution in non standard and complex conformal irradiation field for treatment planning systems.

  8. Magnetic Resonance Imaging and conformal radiotherapy: Characterization of MRI alone simulation for conformal radiotherapy. Development and evaluation of an automatic volumes of interest segmentation tool for prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Pasquier, David

    2006-01-01

    Radiotherapy is a curative treatment of malignant tumours. Radiotherapy techniques considerably evolved last years with the increasing integration of medical images in conformal radiotherapy. This technique makes it possible to elaborate a complex ballistics conforming to target volume and sparing healthy tissues. The examination currently used to delineate volumes of interest is Computed Tomography (CT), on account of its geometrical precision and the information that it provides on electronic densities needed to dose calculation. Magnetic Resonance Imaging (MRI) ensures a more precise delineation of target volumes in many locations, such as pelvis and brain. For pelvic tumours, the use of MRI needs image registration, which complicates treatment planning and poses the problem of the lack of in vivo standard method of validation. The obstacles in the use of MRI alone in treatment planning were evaluated. Neither geometrical distortion linked with the system and the patient nor the lack of information on electronic densities represent stumbling obstacles. Distortion remained low even in edge of large field of view on modern machines. The assignment of electronic densities to bone structures and soft tissues in MR images permitted to obtain equivalent dosimetry to that carried out on the original CT, with a good reproducibility and homogeneous distribution within target volume. The assignment of electronic densities could not be carried out using 20 MV photons and suitable ballistics. The development of Image Guided Radiotherapy could facilitate the use of MRI alone in treatment planning. Target volumes and organ at risk delineation is a time consuming task in radiotherapy planning. We took part in the development and evaluated a method of automatic and semi automatic delineation of volumes of interest from MRI images for prostate cancer radiotherapy. For prostate and organ at risk automatic delineation an organ model-based method and a seeded region growing method

  9. Three-dimensional conformal radiation therapy: the tomo-therapy approach

    International Nuclear Information System (INIS)

    Linthout, N.; Verellen, D.; Coninck, P. de; Bel, A.; Storme, G.

    2000-01-01

    Conformal radiation therapy allows the possibility of delivering high doses at the tumor volume whilst limiting the dose to the surrounding tissues and diminishing the secondary effects. With the example of the conformal radiation therapy used at the AZ VU8 (3DCRT and tomo-therapy), two treatment plans of a left ethmoid carcinoma will be evaluated and discussed in detail. The treatment of ethmoid cancer is technically difficult for both radiation therapy and surgery because of the anatomic constraints and patterns of local spread. A radiation therapy is scheduled to be delivered after surgical resection of the tumor. The treatment plan for the radiation therapy was calculated on a three-dimensional (3D) treatment planning system based on virtual simulation with a beam's eye view: George Sherouse's Gratis. An effort was made to make the plan as conformal and as homogeneous as possible to deliver a dose of 66 Gy in 33 fractions at the tumor bed with a maximum dose of 56 Gy to the right optic nerve and the chiasma. To establish the clinical utility and potential advantages of tomo-therapy over 3DCRT for ethmoid carcinoma, the treatment of this patient was also planned with Peacock Plant. For both treatment plans the isodose distributions and cumulative dose volume histograms (CDVH) were computed. Superimposing the CDVHs yielded similar curves for the target and an obvious improvement for organs at risk such as the chiasma, brainstem and the left eye when applying tomo-therapy. These results have also been reflected in the tumor control probabilities (equal for both plans) and the normal tissue complication probabilities (NTCP), yielding significant reductions in NTCP for tomo-therapy. The probability of uncomplicated tumor control was 52.7% for tomo-therapy against 38.3% for 3DCRT. (authors)

  10. SU-F-T-499: Anatomic Features for Selection of Electronic Tissue Compensation Radiotherapy in Early-Stage Breast Cancer Patients After Breast-Conserving Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Song, Y; Gan, L; Chen, X; Zhang, T; Ren, G [Chongqing Medical University, Chongqing, Chongqing (China); Zhang, M [Rutgers Cancer Institute of New Jersey, Rutgers The State University of New, New Brunswick, New Jersey (United States); Yue, N [Rutgers University, New Brunswick, NJ (United States)

    2016-06-15

    Purpose: To explore the correlations between anatomic features and dose-volumetric parameters in 3DCRT and eComp whole breast irradiation and identify the feasibility of anatomic parameters to predict the planning method selection. Methods: We compared the effectiveness between conventional three-dimensional conformal radiotherapy (3DCRT) and electronic tissue compensation (eComp) for whole breast irradiation. 3DCRT and eComp planning techniques were used to generate treatment plans for 60 whole breast patients, respectively. The planning goal was to cover 95% of the planning target volume (PTV) with 95% of the prescription dose while minimizing dose to lung, heart, and skin. Statistical analyses were performed between critical organ doses and patient anatomic features, i.e., central lung distance (CLD), maximal heart distance (MHD), maximal heart length (MHL) and breast separation (BS). Results: Comparing to 3DCRT plans, on the average, eComp treatment planning process was about 7 minutes longer, but resulted in lower lung V20Gy, lower mean skin dose, with similar heart dose. The benefits were more pronounced for larger breast patients. To keep the lung V20Gy lower than 20% and mean skin dose lower than 85% of the prescription dose, eComp was the preferred method for patients with more than 2.3 cm CLD or larger than 22.5 cm BS. Conclusion: The study results may be useful in providing a handy criterion in clinical practice allowing us to easily choose between different planning techniques to satisfy the planning goal with minimal increase in complexity and cost. This study was supported by National Natural Science Foundation of China (NO. 31420103915) and Chongqing Health and Family Planning Commission Project (2015MSXM012).

  11. SU-F-T-499: Anatomic Features for Selection of Electronic Tissue Compensation Radiotherapy in Early-Stage Breast Cancer Patients After Breast-Conserving Surgery

    International Nuclear Information System (INIS)

    Song, Y; Gan, L; Chen, X; Zhang, T; Ren, G; Zhang, M; Yue, N

    2016-01-01

    Purpose: To explore the correlations between anatomic features and dose-volumetric parameters in 3DCRT and eComp whole breast irradiation and identify the feasibility of anatomic parameters to predict the planning method selection. Methods: We compared the effectiveness between conventional three-dimensional conformal radiotherapy (3DCRT) and electronic tissue compensation (eComp) for whole breast irradiation. 3DCRT and eComp planning techniques were used to generate treatment plans for 60 whole breast patients, respectively. The planning goal was to cover 95% of the planning target volume (PTV) with 95% of the prescription dose while minimizing dose to lung, heart, and skin. Statistical analyses were performed between critical organ doses and patient anatomic features, i.e., central lung distance (CLD), maximal heart distance (MHD), maximal heart length (MHL) and breast separation (BS). Results: Comparing to 3DCRT plans, on the average, eComp treatment planning process was about 7 minutes longer, but resulted in lower lung V20Gy, lower mean skin dose, with similar heart dose. The benefits were more pronounced for larger breast patients. To keep the lung V20Gy lower than 20% and mean skin dose lower than 85% of the prescription dose, eComp was the preferred method for patients with more than 2.3 cm CLD or larger than 22.5 cm BS. Conclusion: The study results may be useful in providing a handy criterion in clinical practice allowing us to easily choose between different planning techniques to satisfy the planning goal with minimal increase in complexity and cost. This study was supported by National Natural Science Foundation of China (NO. 31420103915) and Chongqing Health and Family Planning Commission Project (2015MSXM012).

  12. Late Side Effects After Image Guided Intensity Modulated Radiation Therapy Compared to 3D-Conformal Radiation Therapy for Prostate Cancer: Results From 2 Prospective Cohorts

    Energy Technology Data Exchange (ETDEWEB)

    Wortel, Ruud C.; Incrocci, Luca [Department of Radiation Oncology, Erasmus Medical Center Cancer Institute, Rotterdam (Netherlands); Pos, Floris J.; Heide, Uulke A. van der; Lebesque, Joos V. [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Aluwini, Shafak [Department of Radiation Oncology, Erasmus Medical Center Cancer Institute, Rotterdam (Netherlands); Witte, Marnix G. [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Heemsbergen, Wilma D., E-mail: w.heemsbergen@nki.nl [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands)

    2016-06-01

    Purpose: Technical developments in the field of external beam radiation therapy (RT) enabled the clinical introduction of image guided intensity modulated radiation therapy (IG-IMRT), which improved target conformity and allowed reduction of safety margins. Whether this had an impact on late toxicity levels compared to previously applied three-dimensional conformal radiation therapy (3D-CRT) is currently unknown. We analyzed late side effects after treatment with IG-IMRT or 3D-CRT, evaluating 2 prospective cohorts of men treated for localized prostate cancer to investigate the hypothesized reductions in toxicity. Methods and Materials: Patients treated with 3D-CRT (n=189) or IG-IMRT (n=242) to 78 Gy in 39 fractions were recruited from 2 Dutch randomized trials with identical toxicity scoring protocols. Late toxicity (>90 days after treatment) was derived from self-assessment questionnaires and case report forms, according to Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer (RTOG-EORTC) scoring criteria. Grade ≥2 endpoints included gastrointestinal (GI) rectal bleeding, increased stool frequency, discomfort, rectal incontinence, proctitis, and genitourinary (GU) obstruction, increased urinary frequency, nocturia, urinary incontinence, and dysuria. The Cox proportional hazards regression model was used to compare grade ≥2 toxicities between both techniques, adjusting for other modifying factors. Results: The 5-year cumulative incidence of grade ≥2 GI toxicity was 24.9% for IG-IMRT and 37.6% following 3D-CRT (adjusted hazard ratio [HR]: 0.59, P=.005), with significant reductions in proctitis (HR: 0.37, P=.047) and increased stool frequency (HR: 0.23, P<.001). GU grade ≥2 toxicity levels at 5 years were comparable with 46.2% and 36.4% following IG-IMRT and 3D-CRT, respectively (adjusted HR: 1.19, P=.33). Other strong predictors (P<.01) of grade ≥2 late toxicity were baseline complaints, acute toxicity, and age

  13. Late Side Effects After Image Guided Intensity Modulated Radiation Therapy Compared to 3D-Conformal Radiation Therapy for Prostate Cancer: Results From 2 Prospective Cohorts

    International Nuclear Information System (INIS)

    Wortel, Ruud C.; Incrocci, Luca; Pos, Floris J.; Heide, Uulke A. van der; Lebesque, Joos V.; Aluwini, Shafak; Witte, Marnix G.; Heemsbergen, Wilma D.

    2016-01-01

    Purpose: Technical developments in the field of external beam radiation therapy (RT) enabled the clinical introduction of image guided intensity modulated radiation therapy (IG-IMRT), which improved target conformity and allowed reduction of safety margins. Whether this had an impact on late toxicity levels compared to previously applied three-dimensional conformal radiation therapy (3D-CRT) is currently unknown. We analyzed late side effects after treatment with IG-IMRT or 3D-CRT, evaluating 2 prospective cohorts of men treated for localized prostate cancer to investigate the hypothesized reductions in toxicity. Methods and Materials: Patients treated with 3D-CRT (n=189) or IG-IMRT (n=242) to 78 Gy in 39 fractions were recruited from 2 Dutch randomized trials with identical toxicity scoring protocols. Late toxicity (>90 days after treatment) was derived from self-assessment questionnaires and case report forms, according to Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer (RTOG-EORTC) scoring criteria. Grade ≥2 endpoints included gastrointestinal (GI) rectal bleeding, increased stool frequency, discomfort, rectal incontinence, proctitis, and genitourinary (GU) obstruction, increased urinary frequency, nocturia, urinary incontinence, and dysuria. The Cox proportional hazards regression model was used to compare grade ≥2 toxicities between both techniques, adjusting for other modifying factors. Results: The 5-year cumulative incidence of grade ≥2 GI toxicity was 24.9% for IG-IMRT and 37.6% following 3D-CRT (adjusted hazard ratio [HR]: 0.59, P=.005), with significant reductions in proctitis (HR: 0.37, P=.047) and increased stool frequency (HR: 0.23, P<.001). GU grade ≥2 toxicity levels at 5 years were comparable with 46.2% and 36.4% following IG-IMRT and 3D-CRT, respectively (adjusted HR: 1.19, P=.33). Other strong predictors (P<.01) of grade ≥2 late toxicity were baseline complaints, acute toxicity, and age

  14. A dosimetric comparison between traditionally planned and inverse planned radiation therapy of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Wu, V.W.C.; Sham, J.S.T.; Kwong, D.L.W.

    2003-01-01

    This study applied inverse planning in 3-dimensional conformal radiation therapy (3DCRT) of non-small cell lung cancer (NSCLC) patients and evaluated its dosimetric results by comparison with the forward planning of 3DCRT and inverse planning of intensity modulated radiotherapy (IMRT). For each of the 15 NSCLC patients recruited, the forward 3DCRT, inverse 3DCRT and inverse EVIRT plans were produced using the FOCUS treatment planning system. The dosimetric results and the planner's time of all treatment plans were recorded and compared. The inverse 3DCRT plans demonstrated the best target dose homogeneity among the three planning methods. The tumour control probability of the inverse 3DCRT plans was similar to the forward plans (p 0.217) but inferior to the IMRT plans (p < 0.001). A similar pattern was observed in uncomplicated tumour control. The average planning time for the inverse 3DCRT plans was the shortest and its difference was significant compared with the forward 3DCRT plans (p < 0.001) but not with the IMRT plans (p = 0.276). In conclusion, inverse planning for 3DCRT is a reasonable alternative to the forward planning for NSCLC patients with a reduction of the planner's time. However, further dose escalation and improvement of tumour control have to rely on IMRT. Copyright (2003) Australian Institute of Radiography

  15. Dosimetric comparison of standard three-dimensional conformal radiotherapy followed by intensity-modulated radiotherapy boost schedule (sequential IMRT plan) with simultaneous integrated boost-IMRT (SIB IMRT) treatment plan in patients with localized carcinoma prostate.

    Science.gov (United States)

    Bansal, A; Kapoor, R; Singh, S K; Kumar, N; Oinam, A S; Sharma, S C

    2012-07-01

    DOSIMETERIC AND RADIOBIOLOGICAL COMPARISON OF TWO RADIATION SCHEDULES IN LOCALIZED CARCINOMA PROSTATE: Standard Three-Dimensional Conformal Radiotherapy (3DCRT) followed by Intensity Modulated Radiotherapy (IMRT) boost (sequential-IMRT) with Simultaneous Integrated Boost IMRT (SIB-IMRT). Thirty patients were enrolled. In all, the target consisted of PTV P + SV (Prostate and seminal vesicles) and PTV LN (lymph nodes) where PTV refers to planning target volume and the critical structures included: bladder, rectum and small bowel. All patients were treated with sequential-IMRT plan, but for dosimetric comparison, SIB-IMRT plan was also created. The prescription dose to PTV P + SV was 74 Gy in both strategies but with different dose per fraction, however, the dose to PTV LN was 50 Gy delivered in 25 fractions over 5 weeks for sequential-IMRT and 54 Gy delivered in 27 fractions over 5.5 weeks for SIB-IMRT. The treatment plans were compared in terms of dose-volume histograms. Also, Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) obtained with the two plans were compared. The volume of rectum receiving 70 Gy or more (V > 70 Gy) was reduced to 18.23% with SIB-IMRT from 22.81% with sequential-IMRT. SIB-IMRT reduced the mean doses to both bladder and rectum by 13% and 17%, respectively, as compared to sequential-IMRT. NTCP of 0.86 ± 0.75% and 0.01 ± 0.02% for the bladder, 5.87 ± 2.58% and 4.31 ± 2.61% for the rectum and 8.83 ± 7.08% and 8.25 ± 7.98% for the bowel was seen with sequential-IMRT and SIB-IMRT plans respectively. For equal PTV coverage, SIB-IMRT markedly reduced doses to critical structures, therefore should be considered as the strategy for dose escalation. SIB-IMRT achieves lesser NTCP than sequential-IMRT.

  16. A comprehensive dosimetric study of pancreatic cancer treatment using three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated radiation therapy (VMAT), and passive-scattering and modulated-scanning proton therapy (PT)

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Xuanfeng; Dionisi, Francesco; Tang, Shikui; Ingram, Mark; Hung, Chun-Yu; Prionas, Evangelos; Lichtenwalner, Phil; Butterwick, Ian; Zhai, Huifang; Yin, Lingshu; Lin, Haibo; Kassaee, Alireza; Avery, Stephen, E-mail: stephen.avery@uphs.upenn.edu

    2014-07-01

    With traditional photon therapy to treat large postoperative pancreatic target volume, it often leads to poor tolerance of the therapy delivered and may contribute to interrupted treatment course. This study was performed to evaluate the potential advantage of using passive-scattering (PS) and modulated-scanning (MS) proton therapy (PT) to reduce normal tissue exposure in postoperative pancreatic cancer treatment. A total of 11 patients with postoperative pancreatic cancer who had been previously treated with PS PT in University of Pennsylvania Roberts Proton Therapy Center from 2010 to 2013 were identified. The clinical target volume (CTV) includes the pancreatic tumor bed as well as the adjacent high-risk nodal areas. Internal (iCTV) was generated from 4-dimensional (4D) computed tomography (CT), taking into account target motion from breathing cycle. Three-field and 4-field 3D conformal radiation therapy (3DCRT), 5-field intensity-modulated radiation therapy, 2-arc volumetric-modulated radiation therapy, and 2-field PS and MS PT were created on the patients’ average CT. All the plans delivered 50.4 Gy to the planning target volume (PTV). Overall, 98% of PTV was covered by 95% of the prescription dose and 99% of iCTV received 98% prescription dose. The results show that all the proton plans offer significant lower doses to the left kidney (mean and V{sub 18} {sub Gy}), stomach (mean and V{sub 20} {sub Gy}), and cord (maximum dose) compared with all the photon plans, except 3-field 3DCRT in cord maximum dose. In addition, MS PT also provides lower doses to the right kidney (mean and V{sub 18} {sub Gy}), liver (mean dose), total bowel (V{sub 20} {sub Gy} and mean dose), and small bowel (V{sub 15} {sub Gy} absolute volume ratio) compared with all the photon plans and PS PT. The dosimetric advantage of PT points to the possibility of treating tumor bed and comprehensive nodal areas while providing a more tolerable treatment course that could be used for dose

  17. A comprehensive dosimetric study of pancreatic cancer treatment using three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated radiation therapy (VMAT), and passive-scattering and modulated-scanning proton therapy (PT)

    International Nuclear Information System (INIS)

    Ding, Xuanfeng; Dionisi, Francesco; Tang, Shikui; Ingram, Mark; Hung, Chun-Yu; Prionas, Evangelos; Lichtenwalner, Phil; Butterwick, Ian; Zhai, Huifang; Yin, Lingshu; Lin, Haibo; Kassaee, Alireza; Avery, Stephen

    2014-01-01

    With traditional photon therapy to treat large postoperative pancreatic target volume, it often leads to poor tolerance of the therapy delivered and may contribute to interrupted treatment course. This study was performed to evaluate the potential advantage of using passive-scattering (PS) and modulated-scanning (MS) proton therapy (PT) to reduce normal tissue exposure in postoperative pancreatic cancer treatment. A total of 11 patients with postoperative pancreatic cancer who had been previously treated with PS PT in University of Pennsylvania Roberts Proton Therapy Center from 2010 to 2013 were identified. The clinical target volume (CTV) includes the pancreatic tumor bed as well as the adjacent high-risk nodal areas. Internal (iCTV) was generated from 4-dimensional (4D) computed tomography (CT), taking into account target motion from breathing cycle. Three-field and 4-field 3D conformal radiation therapy (3DCRT), 5-field intensity-modulated radiation therapy, 2-arc volumetric-modulated radiation therapy, and 2-field PS and MS PT were created on the patients’ average CT. All the plans delivered 50.4 Gy to the planning target volume (PTV). Overall, 98% of PTV was covered by 95% of the prescription dose and 99% of iCTV received 98% prescription dose. The results show that all the proton plans offer significant lower doses to the left kidney (mean and V 18 Gy ), stomach (mean and V 20 Gy ), and cord (maximum dose) compared with all the photon plans, except 3-field 3DCRT in cord maximum dose. In addition, MS PT also provides lower doses to the right kidney (mean and V 18 Gy ), liver (mean dose), total bowel (V 20 Gy and mean dose), and small bowel (V 15 Gy absolute volume ratio) compared with all the photon plans and PS PT. The dosimetric advantage of PT points to the possibility of treating tumor bed and comprehensive nodal areas while providing a more tolerable treatment course that could be used for dose escalation and combining with radiosensitizing

  18. Hyperfractionated conformal radiotherapy in locally advanced prostate cancer: results of a dose escalation study

    International Nuclear Information System (INIS)

    Forman, Jeffrey D.; Duclos, Marie; Shamsa, Falah; Porter, Arthur T.; Orton, Colin

    1996-01-01

    Purpose: This study was initiated to assess the incidence of chronic complications and histologic and biochemical control following hyperfractionated conformal radiotherapy in patients with locally advanced prostate cancer. Methods and Materials: Between October 1991 and October 1994, 49 patients with locally advanced prostate cancer were entered on the first two dose levels of a prospective dose-escalation study using hyperfractionated three dimensional conformal radiotherapy. The first 25 patients received a minimum tumor dose of 78 Gy to the prostate and seminal vesicles in 6 weeks at 1.3 Gy, b.i.d. No increase in chronic toxicity compared with conventional radiotherapy was noted; therefore, an additional 24 patients were treated to a minimum tumor dose of 82.8 Gy to the prostate and seminal vesicles in 7 weeks at 1.15 Gy, b.i.d. Toxicity was scored according to the Radiation Therapy Oncology Group morbidity grading scale. Efficacy was assessed through scheduled postradiation prostate specific antigen values and ultrasound-guided biopsies. The median follow-up for the entire group was 20 months. Results: The hyperfractionated external radiation was well tolerated with minimal acute morbidity. At 30 months, the actuarial probability of Grade 2 gastrointestinal toxicity was 17%. At 30 months, the actuarial probability of Grade 2 genitourinary toxicity was 16%. There was no statistically significant difference between the two dose levels. No Grade 3 or 4 gastrointestinal or genitourinary toxicity was noted. At 12 months, 84% of patients had a prostate specific antigen ≤ 4; and 53%; ≤ 1 ng/ml. At 12 months, 71% of patients had post radiation biopsies that were either negative (55%) or showed a marked therapeutic effect (16%). Conclusion: The use of hyperfractionated conformal radiotherapy facilitated dose escalation with no increase in chronic toxicity compared to standard doses. The initial tumor response based on prostate specific antigen measurements and

  19. Four-dimensional CT-based evaluation of volumetric modulated arc therapy for abdominal lymph node metastasis from hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Zhang Li; Xi Mian; Deng Xiaowu; Li Qiaoqiao; Huang Xiaoyan; Liu Mengzhong

    2012-01-01

    This study aimed to identify the potential benefits and limitations of a new volumetric modulated arc therapy (VMAT) planning system in Monaco, compared with conventional intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3DCRT). Four-dimensional CT scans of 13 patients with abdominal lymph node metastasis from hepatocellular carcinoma were selected. Internal target volume was defined as the combined volume of clinical target volumes (CTVs) in the multiple four-dimensional computed tomography (4DCT) phases. Dose prescription was set to 45 Gy for the planning target volume (PTV) in daily 3.0-Gy fractions. The PTV dose coverage, organs at risk (OAR) doses, delivery parameters and treatment accuracy were assessed. Compared with 3DCRT, both VMAT and IMRT provided a systematic improvement in PTV coverage and homogeneity. Planning objectives were not fulfilled for the right kidney, in which the 3DCRT plans exceeded the dose constraints in two patients. Equivalent target coverage and sparing of OARs were achieved with VMAT compared with IMRT. The number of MU/fraction was 462±68 (3DCRT), 564±105 (IMRT) and 601±134 (VMAT), respectively. Effective treatment times were as follows: 1.8±0.2 min (3DCRT), 6.1±1.5 min (IMRT) and 4.8±1.0 min (VMAT). This study suggests that the VMAT plans generated in Monaco improved delivery efficiency for equivalent dosimetric quality to IMRT, and were superior to 3DCRT in target coverage and sparing of most OARs. However, the superiority of VMAT over IMRT in delivery efficiency is limited. (author)

  20. SU-E-T-346: Effect of Jaw Position On Dose to Critical Structures in 3-D Conformal Radiotherapy Treatment of Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Paudel, N; Han, E; Liang, X; Morrill, S; Zhang, X; Hardee, M; Penagaricano, J; Ratanatharathorn, V [Vaneerat, University of Arkansas for Medical Sciences, Little Rock, AR (United States)

    2015-06-15

    Purpose: Three-dimensional conformal therapy remains a valid and widely used modality for pancreatic radiotherapy treatment. It usually meets dose constraints on critical structures. However, careful positioning of collimation jaws can reduce dose to the critical structures. Here we investigate the dosimetric effect of jaw position in MLC-based 3-D conformal treatment planning on critical structures. Methods: We retrospectively selected seven pancreatic cancer patients treated with 3-D conformal radiotherapy. We started with treatment plans (Varian Truebeam LINAC, Eclipse TPS, AAA, 18MV) having both x and y jaws aligned with the farthest extent of the block outline (8mm around PTV). Then we subsequently moved either both x-jaws or all x and y jaws outwards upto 3 cm in 1 cm increments and investigated their effect on average and maximum dose to neighboring critical structures keeping the same coverage to treatment volume. Results: Lateral displacement of both x-jaws by 1cm each increased kidney and spleen mean dose by as much as 1.7% and 1.3% respectively and superior inferior displacement increased liver, right kidney, stomach and spleen dose by as much as 2.1%, 2%, 5.2% and 1.6% respectively. Displacement of all x and y-jaws away by 1cm increased the mean dose to liver, right kidney, left kidney, bowels, cord, stomach and spleen by as much as 4.9%, 5.9%, 2.1%, 2.8%, 7.4%, 10.4% and 4.2% respectively. Percentage increase in mean dose due to 2 and 3cm jaw displacement increased almost linearly with the displaced distance. Changes in maximum dose were much smaller (mostly negligible) than the changes in mean dose. Conclusion: Collimation jaw position affects dose mostly to critical structures adjacent to it. Though treatment plans with MLCs conforming the block margin usually meet dose constraints to critical structures, keeping jaws all the way in, to the edge of the block reduces dose to the critical structures during radiation treatment.

  1. Dose escalation with 3D conformal treatment: five year outcomes, treatment optimization, and future directions

    International Nuclear Information System (INIS)

    Hanks, Gerald E.; Hanlon, Alexandra L. M.S.; Schultheiss, Timothy E.; Pinover, Wayne H.; Movsas, Benjamin; Epstein, Barry E.; Hunt, Margie

    1998-01-01

    Purpose: To report the 5-year outcomes of dose escalation with 3D conformal treatment (3DCRT) of prostate cancer. Methods and Materials: Two hundred thirty-two consecutive patients were treated with 3DCRT alone between 6/89 and 10/92 with ICRU reporting point dose that increased from 63 to 79 Gy. The median follow-up was 60 months, and any patient free of clinical or biochemical evidence of disease was termed bNED. Biochemical failure was defined as prostate-specific antigen (PSA) rising on two consecutive recordings and exceeding 1.5 ng/ml. Morbidity was reported by the Radiation Therapy Oncology Group (RTOG) scale, the Late Effects Normal Tissue (LENT) scale, and a Fox Chase modification of the latter (FC-LENT). All patients were treated with a four-field technique with a 1 cm clinical target volume (CTV) to planning target volume (PTV) margin to the prostate or prostate boost; the CTV and gross tumor volume (GTV) were the same. Actuarial rates of outcome were calculated by Kaplan-Meier and cumulative incidence methods and compared using the log rank and Gray's test statistic, respectively. Cox regression models were used to establish prognostic factors predictive of the various measures of outcome. Five-year Kaplan-Meier bNED rates were utilized by dose group to estimate logit response models for bNED and late morbidity. Results: PSA 10 ng/ml based on 5-year bNED results. No dose response was observed for patients with pretreatment PSA 10 ng/ml strongly suggests that clinical trials employing radiation should investigate the use of 3DCRT and prostate doses of 76-80 Gy

  2. Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer

    International Nuclear Information System (INIS)

    Patel, Rakesh R.; Orton, Nigel; Tome, Wolfgang A.; Chappell, Rick; Ritter, Mark A.

    2003-01-01

    , respectively. Averaged over all conditions, inflation of the rectal balloon resulted in a significant reduction in rectal volume receiving ≥65 Gy to a mean ratio of 0.61 (P=0.01) or, in other words, a mean fractional high dose rectal sparing of 39%. There was a slight overall increase to 1.13 in the relative volume of bladder receiving at least 65 Gy; however, this was not significant (P=0.6). Use of an endorectal balloon with a non-image-guided 3D-CRT plan produced about as much rectal dose sparing as a highly conformal, image-guided IMRT approach without a balloon. However, inclusion of a balloon with IMRT produced further rectal sparing still. Conclusion: These results indicate that use of a rectal balloon with a 3D-CRT plan incorporating typical treatment margins will produce significant high dose rectal sparing that is comparable to that achieved by a highly conformal IMRT with ultrasound localization. Further sparing is achieved with the inclusion of a balloon catheter in an IMRT plan. Thus, in addition to a previously reported advantage of prostate immobilization, the use of a rectal displacement balloon during daily treatment results in high dose rectal wall sparing during both modestly and highly conformal radiotherapy. Such sparing could assist in controlling and limiting rectal toxicity during increasingly aggressive dose escalation

  3. Fractionated stereotactic conformal radiotherapy following conservative surgery in the control of craniopharyngiomas

    International Nuclear Information System (INIS)

    Minniti, Giuseppe; Saran, Frank; Traish, Daphne; Soomal, Rubin; Sardell, Susan; Gonsalves, Adam; Ashley, Susan; Warrington, Jim; Burke, Kevin; Mosleh-Shirazi, Amin; Brada, Michael

    2007-01-01

    Purpose: To describe the technique and results of stereotactically guided conformal radiotherapy (SCRT) in patients with craniopharyngioma after conservative surgery. Methods and materials: Thirty-nine patients with craniopharyngioma aged 3-68 years (median age 18 years) were treated with SCRT between June 1994 and January 2003. All patients were referred for radiotherapy after undergoing one or more surgical procedures. Treatment was delivered in 30-33 daily fractions over 6-6.5 weeks to a total dose of 50 Gy using 6 MV photons. Outcome was assessed prospectively. Results: At a median follow-up of 40 months (range 3-88 months) the 3- and 5-year progression-free survival (PFS) was 97% and 92%, and 3- and 5-year survival 100%. Two patients required further debulking surgery for progressive disease 8 and 41 months after radiotherapy. Twelve patients (30%) had acute clinical deterioration due to cystic enlargement of craniopharyngioma following SCRT and required cyst aspiration. One patient with severe visual impairment prior to radiotherapy had visual deterioration following SCRT. Seven out of 10 patients with a normal pituitary function before SCRT had no endocrine deficits following treatment. Conclusion: SCRT as a high-precision technique of localized RT is suitable for the treatment of incompletely excised craniopharyngioma. The local control, toxicity and survival outcomes are comparable to results reported following conventional external beam RT. Longer follow-up is required to assess long-term efficacy and toxicity, particularly in terms of potential reduction in treatment related late toxicity

  4. Late radiation side effects, cosmetic outcomes and pain in breast cancer patients after breast-conserving surgery and three-dimensional conformal radiotherapy. Risk-modifying factors

    International Nuclear Information System (INIS)

    Hille-Betz, Ursula; Soergel, Philipp; Kundu, Sudip; Klapdor, Ruediger; Hillemanns, Peter; Vaske, Bernhard; Bremer, Michael; Henkenberens, Christoph

    2016-01-01

    The purpose of this work was to identify parameters influencing the risk of late radiation side effects, fair or poor cosmetic outcomes (COs) and pain in breast cancer patients after breast-conserving therapy (BCT) and three-dimensional conformal radiotherapy (3D-CRT). Between 2006 and 2013, 159 patients were treated at the Hannover Medical School. Physician-rated toxicity according to the LENT-SOMA criteria, CO and pain were assessed by multivariate analysis. LENT-SOMA grade 1-4 toxicity was observed as follows: fibrosis 10.7 %, telangiectasia 1.2 %, arm oedema 8.8 % and breast oedema 5.0 %. In addition, 15.1 % of patients reported moderate or severe breast pain, and 21.4 % complained about moderate or severe pain in the arm or shoulder. In multivariate analysis, axillary clearing (AC) was significantly associated with lymphoedema of the arm [odds ratio (OR) 4.37, p = 0.011, 95 % confidence interval (CI) 1.4-13.58]. Breast oedema was also highly associated with AC (OR 10.59, p = 0.004, 95 % CI 2.1-53.36), a ptosis grade 2/3 or pseudoptosis and a bra size ≥ cup C (OR 5.34, p = 0.029, 95 % CI 1.2-24.12). A ptosis grade 2/3 or pseudoptosis and a bra size ≥ cup C were the parameters significantly associated with an unfavourable CO (OR 3.19, p = 0.019, 95 % CI 1.2-8.4). Concerning chronic breast pain, we found a trend related to the prescribed radiation dose including boost (OR 1.077, p = 0.060, 95 % CI 0.997-1.164). Chronic shoulder or arm pain was statistically significantly associated with lymphoedema of the arm (OR 3.9, p = 0.027, 95 % CI 1.17-13.5). Chronic arm and breast oedema were significantly influenced by the extent of surgery (AC). Ptotic and large breasts were significantly associated with unfavourable COs and chronic breast oedema. Late toxicities exclusive breast pain were not associated with radiotherapy parameters. (orig.) [de

  5. Pancreatic cancer planning: Complex conformal vs modulated therapies

    International Nuclear Information System (INIS)

    Chapman, Katherine L.; Witek, Matthew E.; Chen, Hongyu; Showalter, Timothy N.; Bar-Ad, Voichita; Harrison, Amy S.

    2016-01-01

    To compare the roles of intensity-modulated radiation therapy (IMRT) and volumetric- modulated arc therapy (VMAT) therapy as compared to simple and complex 3-dimensional chemoradiotherpy (3DCRT) planning for resectable and borderline resectable pancreatic cancer. In all, 12 patients who received postoperative radiotherapy (8) or neoadjuvant concurrent chemoradiotherapy (4) were evaluated retrospectively. Radiotherapy planning was performed for 4 treatment techniques: simple 4-field box, complex 5-field 3DCRT, 5 to 6-field IMRT, and single-arc VMAT. All volumes were approved by a single observer in accordance with Radiation Therapy Oncology Group (RTOG) Pancreas Contouring Atlas. Plans included tumor/tumor bed and regional lymph nodes to 45 Gy; with tumor/tumor bed boosted to 50.4 Gy, at least 95% of planning target volume (PTV) received the prescription dose. Dose-volume histograms (DVH) for multiple end points, treatment planning, and delivery time were assessed. Complex 3DCRT, IMRT, and VMAT plans significantly (p < 0.05) decreased mean kidney dose, mean liver dose, liver (V 30 , V 35 ), stomach (D 10 %), stomach (V 45 ), mean right kidney dose, and right kidney (V 15 ) as compared with the simple 4-field plans that are most commonly reported in the literature. IMRT plans resulted in decreased mean liver dose, liver (V 35 ), and left kidney (V 15 , V 18 , V 20 ). VMAT plans decreased small bowel (D 10 %, D 15 %), small bowel (V 35 , V 45 ), stomach (D 10 %, D 15 %), stomach (V 35 , V 45 ), mean liver dose, liver (V 35 ), left kidney (V 15 , V 18 , V 20 ), and right kidney (V 18 , V 20 ). VMAT plans significantly decreased small bowel (D 10 %, D 15 %), left kidney (V 20 ), and stomach (V 45 ) as compared with IMRT plans. Treatment planning and delivery times were most efficient for simple 4-field box and VMAT. Excluding patient setup and imaging, average treatment delivery was within 10 minutes for simple and complex 3DCRT, IMRT, and VMAT treatments. This article

  6. Efficient CT simulation of the four-field technique for conformal radiotherapy of prostate carcinoma

    International Nuclear Information System (INIS)

    Valicenti, Richard K.; Waterman, Frank M.; Croce, Raymond J.; Corn, Benjamin; Suntharalingam, Nagalingam; Curran, Walter J.

    1997-01-01

    Purpose: Conformal radiotherapy of prostate carcinoma relies on contouring of individual CT slices for target and normal tissue localization. This process can be very time consuming. In the present report, we describe a method to more efficiently localize pelvic anatomy directly from digital reconstructed radiographs (DRRs). Materials and Methods: Ten patients with prostate carcinoma underwent CT simulation (the spiral mode at 3 mm separation) for conformal four-field 'box' radiotherapy. The bulbous urethra and bladder were opacified with iodinated contrast media. On lateral and anteroposterior DRRs, the volume of interest (VOI) was restricted to 1.0-1.5 cm tissue thickness to optimize digital radiograph reconstruction of the prostate and seminal vesicles. By removing unessential voxel elements, this method provided direct visualization of those structures. For comparison, the targets of each patient were also obtained by contouring CT axial slices. Results: The method was successfully performed if the target structures were readily visualized and geometrically corresponded to those generated by contouring axial images. The targets in 9 of 10 patients were reliable representations of the CT-contoured volumes. One patient had 18 mm variation due to the lack of bladder opacification. Using VOIs to generate thin tissue DRRs, the time required for target and normal tissue localization was on the average less than 5 min. Conclusion: In CT simulation of the four-field irradiation technique for prostate carcinoma, thin-tissue DRRs allowed for efficient and accurate target localization without requiring individual axial image contouring. This method may facilitate positioning of the beam isocenter and provide reliable conformal radiotherapy

  7. Dosimetric comparison of three-dimensional conformal and intensity modulated radiotherapy in brain glioma

    International Nuclear Information System (INIS)

    Lu Jie; Zhang Guifang; Bai Tong; Yin Yong; Fan Tingyong; Wu Chaoxia

    2009-01-01

    Objective: To investigate the dosimetry advantages of intensity modulated radiotherapy (IMRT)of brain glioma compared with that of three-dimensional conformal radiotherapy (SD CRT). Methods: Ten patients with brain glioma were enrolled in this study. Three-dimensional conf0rmal and intensity modulated radiotherapy plans were performed for each patient. The dose distributions of target volume and normal tissues, conformal index (CI) and heterogeneous index (HI) were analyzed using the dose-volume histogram (DVH). The prescription dose was 60 Gy in 30 fractions. Results: IMRT plans decrease the maximum dose and volume of brainstem, mean dose of affected side parotid and maximum dose of spinal-cord. The CI for PTV of IMRT was superior to that of SD CRT, the HI for PTV has no statistical significance of the two model plans. Conclusions: IMRT plans can obviously decrease the dose and volume of brainstem. IMRT is a potential method in the treatment of brain glioma, and dose escalation was possible in patients with brain glioma. (authors)

  8. Clinical variability of target volume description and treatment plans in conformal radiotherapy in muscle invasive bladder cancer

    International Nuclear Information System (INIS)

    Logue, John P; Sharrock, Carole L; Cowan, Richard A.; Read, Graham; Marrs, Julie; Mott, David

    1996-01-01

    Purpose/Objective: The delineation of tumor and the production of a treatment plan to encompass this is the prime step in radiotherapy planning. Conformal radiotherapy is developing rapidly and although plentiful research has addressed the implementation of the radiotherapy prescription, scant attention has been made to the fundamental step of production, by the clinician, of an appropriate target volume. As part of an ongoing randomized trial of conformal radiotherapy, in bladder cancer, we have therefore assessed the interphysician variability of radiologists and radiation oncologists (RO) in assessing Gross Tumor Volume(GTV) (ICRU 50) and the adherence of the radiation oncologists to the study protocol of producing a Planning Target Volume (PTV). Materials and Methods: Four patients with T3 carcinoma of bladder who had been entered into the trial were identified. The clinical details, MR scans and CT scans were made available. Eight RO and 3 dedicated diagnostic oncology radiologists were invited to directly outline the GTV onto CT images on a planning computer consul. The RO in addition created a PTV following the trial protocol of 15mm margin around the GTV. Three RO sub-specialized in Urological radiotherapy; all RO had completed training. Volumes were produced, for each clinician, and comparison of these volumes and their isocenters were analyzed. In addition the margins allowed were measured and compared. Results: There was a maximum variation ratio (largest to smallest volume outlined) of the GTV in the four cases of 1.74 among radiologists and 3.74 among oncologists. There was a significant difference (p=0.01) in mean GTV between RO and the radiologists. The mean GTV of the RO exceeded the radiologists by a factor of 1.29 with a mean difference of 13.4 cm 3 The between observer variance within speciality comprised only 9.9% of the total variance in the data having accounted for case and observers speciality. The variation ratio in PTV among oncologists

  9. Animation and radiobiological analysis of 3D motion in conformal radiotherapy.

    Science.gov (United States)

    MacKay, R I; Graham, P A; Moore, C J; Logue, J P; Sharrock, P J

    1999-07-01

    To allow treatment plans to be evaluated against the range of expected organ motion and set up error anticipated during treatment. Planning tools have been developed to allow concurrent animation and radiobiological analysis of three dimensional (3D) target and organ motion in conformal radiotherapy. Surfaces fitted to structures outlined on CT studies are projected onto pre-treatment images or onto megavoltage images collected during the patient treatment. Visual simulation of tumour and normal tissue movement is then performed by the application of three dimensional affine transformations, to the selected surface. Concurrent registration of the surface motion with the 3D dose distribution allows calculation of the change in dose to the volume. Realistic patterns of motion can be applied to the structure to simulate inter-fraction motion and set-up error. The biologically effective dose for the structure is calculated for each fraction as the surface moves over the course of the treatment and is used to calculate the normal tissue complication probability (NTCP) or tumour control probability (TCP) for the moving structure. The tool has been used to evaluate conformal therapy plans against set up measurements recorded during patient treatments. NTCP and TCP were calculated for a patient whose set up had been corrected after systematic deviations from plan geometry were measured during treatment, the effect of not making the correction were also assessed. TCP for the moving tumour was reduced if inadequate margins were set for the treatment. Modelling suggests that smaller margins could have been set for the set up corrected during the course of the treatment. The NTCP for the rectum was also higher for the uncorrected set up due to a more rectal tissue falling in the high dose region. This approach provides a simple way for clinical users to utilise information incrementally collected throughout the whole of a patient's treatment. In particular it is possible to

  10. Better compliance with hypofractionation vs. conventional fractionation in adjuvant breast cancer radiotherapy. Results of a single, institutional, retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Rudat, Volker; Nour, Alaa; Hammoud, Mohamed; Abou Ghaida, Salam [Saad Specialist Hospital, Department of Radiation Oncology, Al Khobar (Saudi Arabia)

    2017-05-15

    The aim of the study was to identify factors significantly associated with the occurrence of unintended treatment interruptions in adjuvant breast cancer radiotherapy. Patients treated with postoperative radiotherapy of the breast or chest wall between March 2014 and August 2016 were evaluated. The radiotherapy regimens and techniques applied were either conventional fractionation (CF; 28 daily fractions of 1.8 Gy or 25 fractions of 2.0 Gy) or hypofractionation (HF; 15 daily fractions of 2.67 Gy) with inverse planned intensity-modulated radiotherapy (IMRT) or three-dimensional planned conformal radiotherapy (3DCRT). Logistic regression analysis was used to identify factors associated with noncompliance. Noncompliance was defined as the missing of at least one scheduled radiotherapy fraction. In all, 19 of 140 (13.6%) patients treated with HF and 39 of 146 (26.7%) treated with CF experienced treatment interruptions. Of 23 factors tested, the fractionation regimen emerged as the only independent significant prognostic factor for noncompliance on multivariate analysis (CF; p = 0.007; odds ratio, 2.3; 95% confidence interval, 1.3-4.2). No statistically significant differences concerning the reasons for treatment interruptions could be detected between patients treated with CF or HF. HF is significantly associated with a better patient compliance with the prescribed radiotherapy schedule compared with CF. The data suggest that this finding is basically related to the shorter overall treatment time of HF. (orig.) [German] Ziel der Untersuchung war es, Faktoren zu identifizieren, die mit ungeplanten Behandlungsunterbrechungen bei der adjuvanten Strahlentherapie des Mammakarzinoms assoziiert sind. Es wurden Patienten untersucht, die eine adjuvante Strahlentherapie der Mamma oder Brustwand zwischen Maerz 2014 und August 2016 erhielten. Zur Anwendung kamen als Fraktionierungsprotokoll und strahlentherapeutische Technik eine konventionell fraktionierte (CF; 28 Fraktionen mit

  11. 3D-conformal radiotherapy treatment of high grade gliomas of malignancy

    International Nuclear Information System (INIS)

    Chon Rivas, Ivonne; Chi Ramirez, Daysi; Alert Silva, Jose; Roca Muchuli, Carlos; Leon Gonzalez, Roberto; Perez Penna, Lourdes

    2009-01-01

    Patients diagnosed with high grade gliomas of malignancy (A), have a high mortality rate, about 10% achieve survivals than one year due to poor local control resulting from the inability of high doses of radiation to tumor volume by dose-limiting provided by healthy peritumoral tissues and structures. 3D conformal radiotherapy (RT-3DC) achieves effective tumoricidal high doses with high precision on the tumor with minimal involvement of critical structures near the tumor target volume. From 2005 until 2008 at INOR, a total of 23 patients with histologically confirmed supratentorial gliomas location, histological subtypes of anaplastic astrocytoma (AA) in 8 patients (35%) and Glioblastoma Multiforme (GBM) in 15 patients (65%), aged between 18 and 65, Karnofski scale of 70 or more and total previous surgical resection in 10 patients (43%) or partial in 13 (57%) were included prospectively in this study. The total tumor dose of 66-70 Gy was prescribed with a daily fractionation of 1.8 Gy. All patients underwent CT images (CT) and MRI (MRI) cranial volumes were defined treatment planning according to the concepts of ICRU 50 and 62 with precise immobilization of the head by thermo deformed mask, CT 3mm cuts planning system and 3D treatment planning. Median survival was better in patients younger than 55 years, with high rates of Karnofski, histology of AA and higher percentage of surgical resection. Median survival (Kaplan-Meier method) obtained was 16 months. Survival at 1 and 2 years was 51% and 28% respectively. The RT-3DC can administer higher doses on the tumor with peritumoral healthy protection structures in selected patients with a diagnosis of AA or GBM, increasing local control and potentially overall survival without exacerbating toxicity, thus demonstrating the dose- response of malignant brain tumors. (Author)

  12. Conformal radiotherapy of locally advanced bile duct carcinoma

    International Nuclear Information System (INIS)

    Bouras, N.; Caudry, M.; Bonnel, C.; Trouette, R.; Demeaux, H.; Maire, J.P.; Saric, J.; Rullier, E.

    2002-01-01

    Purpose. - Retrospective study of 23 patients treated with conformal radiotherapy for a locally advanced bile duct carcinoma. Patients and methods. - Eight cases were irradiated after a radical resection (RO), because they were N+; seven after microscopically incomplete resection (R1) ; seven were not resected (R2). A dose of 45 of 50 Gy was delivered, followed by a boost up to 60 Gy in R1 and R2 groups. Concomitant chemotherapy was given in 15 cases. Results.-Late toxicity included a stenosis of the duodenum, and one of the biliary anastomosis. Two patients died from cholangitis, the mechanism of which remains unclear. Five patients are in complete remission, six had a local relapse, four developed a peritoneal carcinosis, and six distant metastases. Actuarial survival rate is 75%, 28% and 7% at 1, 3 and 5 years, respectively (median: 16.5 months). Seven patients are still alive with a 4 to 70 months follow-up. Survival is similar in the 3 small subgroups. The poor local control among RON+ cases might be related to the absence of a boost to the 'tumor bed'. In R1 patients, relapses were mainly distant metastases, where'as local and peritoneal recurrences predominated in R2. Conclusion. - Conformal radio-chemotherapy delivering 60 Gy represents a valuable palliative approach in locally advanced biliary carcinoma. (authors)

  13. A comparison of four patient immobilization devices in the treatment of prostate cancer patients with three dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Song, Paul Y.; Washington, Maxine; Vaida, Florin; Hamilton, Russell; Spelbring, Danny; Wyman, Brenda; Harrison, Joanne; Chen, George T. Y.; Vijayakumar, Srinivasan

    1996-01-01

    Purpose: To determine the variability of patient positioning during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer treated with no immobilization or one of four immobilization devices, and to determine the effects of patient body habitus and pelvic circumference on patient movement with each individual immobilization technique. Methods and Materials: To see whether our immobilization techniques have improved day-to-day patient movement, a retrospective analysis was carried out. A total of 62 patients treated at one facility on a single machine with 3D-CRT via a four-field box technique (anterior-posterior and opposed laterals) in the supine position with either no immobilization or one of four immobilization devices. Five groups of patients were compared: (a) group 1-no immobilization; (b) group 2-alpha cradle from the waist to upper thigh; (c) group 3-alpha cradle from waist to below the knees; (d) group 4-styrofoam leg immobilizer (below knees); and (e) group 5-aquaplast cast encompassing the entire abdomen and pelvis to midthigh with alpha cradle immobilization to their lower legs and feet. Prior to starting radiotherapy, portal films of all four treatment fields were obtained 1 day before treatment. Subsequently, portal films were then obtained at least once a week. Portal films were compared with the simulation films and appropriate changes were made and verified on the next day prior to treatment. A deviation of greater than 0.5 cm or greater was considered to be clinically significant in our analysis. We studied the difference among the types of immobilization and no immobilization by looking at the frequency of movements (overall, and on each of the three axes) that a patient had during the course of his treatment. Using a logistic regression model, the probability of overall and individual directional movement for each group was obtained. In addition, the effects of patient body habitus and pelvic circumference on movement were

  14. Three dimensional-conformal radiotherapy combined with capecitabine chemotherapy for locally advanced (unresectable) rectal cancer

    International Nuclear Information System (INIS)

    Zhu Yaqun; Tian Ye; Zhang Junning; Wang Bin

    2010-01-01

    Objective: To evaluate the compliance and efficacy of chemoradiotherapy for locally advanced (unresectable) rectal cancer. Methods: Thirty eight patients with locally advanced (T4 or recurred) rectal cancer received three dimensional-conformal radiotherapy (for 46 ∼ 50Gy/5 weeks and was boosted to the tumor 16 ∼ 18Gy/2 weeks, 2Gy/fraction, 5 days/week) in combination with capecitabine 1 650mg · m -2 · d -1 , day 1-14, every 3 weeks. Results: The overall response rate was 57.9%, with CR 5 (13.2%), PR 17(44.7%), SD 10 (26.3%), PD 6 (15.8%), median survival time, the 1-year overall survival rate and the 2-year overall survival rate were 18 months, 64.43%, 18.78%, respectively. The remission rate of pain and improvement rate of performance status were 100% and 52.8%. Treatment-related toxicity mainly showed at diarrhea, neutrocytopenia and hand-foot syndrome, the incidence of grade 3 toxicity were 15.8%, 15.8%, 7.9%, respectively. there were no grade 4 toxicity and treatment-related death. Conclusion: Combination of three dimensional-conformal radiotherapy with capecitabine is active in advanced rectal cancer, It is a well-tolerated regimen. (authors)

  15. A new three-dimensional conformal radiotherapy (3DCRT) technique for large breast and/or high body mass index patients: evaluation of a novel fields assessment aimed to reduce extra–target-tissue irradiation

    Science.gov (United States)

    Stimato, Gerardina; Ippolito, Edy; Silipigni, Sonia; Venanzio, Cristina Di; Gaudino, Diego; Fiore, Michele; Trodella, Lucio; D'Angelillo, Rolando Maria; Ramella, Sara

    2016-01-01

    Objective: To develop an alternative three-dimensional treatment plan with standardized fields class solution for whole-breast radiotherapy in patients with large/pendulous breast and/or high body mass index (BMI). Methods: Two treatment plans [tangential fields and standardized five-fields technique (S5F)] for a total dose of 50 Gy/25 fractions were generated for patients with large breasts [planning target volume (PTV) >1000 cm3 and/or BMI >25 kg m−2], supine positioned. S5F plans consist of two wedged tangential beams, anteroposterior: 20° for the right breast and 340° for the left breast, and posteroanterior: 181° for the right breast and 179° for the left breast. A field in field in medial–lateral beam and additional fields were added to reduce hot spot areas and extra–target-tissue irradiation and to improve dose distribution. The percentage of PTV receiving 95% of the prescribed dose (PTV V95%), percentage of PTV receiving 105% of the prescribed dose (PTV V105%), maximal dose to PTV (PTV Dmax), homogeneity index (HI) and conformity index were recorded. V10%, V20%, V105% and V107% of a “proper” normal tissue structure (body-PTV healthy tissue) were recorded. Statistical analyses were performed using SYSTAT v.12.0 (SPSS, Chicago, IL). Results: In 38 patients included, S5F improved HI (8.4 vs 10.1; p ≤ 0.001) and significantly reduced PTV Dmax and PTV V105%. The extra–target-tissue irradiation was significantly reduced using S5F for V105% (cm3) and V107% (cm3) with a very high difference in tissue irradiation (46.6 vs 3.0 cm3, p ≤ 0.001 for V105% and 12.2 vs 0.0 cm3, p ≤ 0.001 for V107% for tangential field and S5F plans, respectively). Only a slight increase in low-dose extra–target-tissue irradiation (V10%) was observed (2.2719 vs 1.8261 cm3, p = 0.002). Conclusion: The S5F technique in patients with large breast or high BMI increases HI and decreases hot spots in extra-target-tissues and can therefore be

  16. Late radiation side effects, cosmetic outcomes and pain in breast cancer patients after breast-conserving surgery and three-dimensional conformal radiotherapy. Risk-modifying factors

    Energy Technology Data Exchange (ETDEWEB)

    Hille-Betz, Ursula; Soergel, Philipp; Kundu, Sudip; Klapdor, Ruediger; Hillemanns, Peter [Hannover Medical School, Department of Obstetrics and Gynaecology, Hannover (Germany); Vaske, Bernhard [Hannover Medical School, Institute of Medical Biometry and Informatics, Hannover (Germany); Bremer, Michael; Henkenberens, Christoph [Hannover Medical School, Department of Radiation Oncology and Special Oncology, Hannover (Germany)

    2016-01-15

    The purpose of this work was to identify parameters influencing the risk of late radiation side effects, fair or poor cosmetic outcomes (COs) and pain in breast cancer patients after breast-conserving therapy (BCT) and three-dimensional conformal radiotherapy (3D-CRT). Between 2006 and 2013, 159 patients were treated at the Hannover Medical School. Physician-rated toxicity according to the LENT-SOMA criteria, CO and pain were assessed by multivariate analysis. LENT-SOMA grade 1-4 toxicity was observed as follows: fibrosis 10.7 %, telangiectasia 1.2 %, arm oedema 8.8 % and breast oedema 5.0 %. In addition, 15.1 % of patients reported moderate or severe breast pain, and 21.4 % complained about moderate or severe pain in the arm or shoulder. In multivariate analysis, axillary clearing (AC) was significantly associated with lymphoedema of the arm [odds ratio (OR) 4.37, p = 0.011, 95 % confidence interval (CI) 1.4-13.58]. Breast oedema was also highly associated with AC (OR 10.59, p = 0.004, 95 % CI 2.1-53.36), a ptosis grade 2/3 or pseudoptosis and a bra size ≥ cup C (OR 5.34, p = 0.029, 95 % CI 1.2-24.12). A ptosis grade 2/3 or pseudoptosis and a bra size ≥ cup C were the parameters significantly associated with an unfavourable CO (OR 3.19, p = 0.019, 95 % CI 1.2-8.4). Concerning chronic breast pain, we found a trend related to the prescribed radiation dose including boost (OR 1.077, p = 0.060, 95 % CI 0.997-1.164). Chronic shoulder or arm pain was statistically significantly associated with lymphoedema of the arm (OR 3.9, p = 0.027, 95 % CI 1.17-13.5). Chronic arm and breast oedema were significantly influenced by the extent of surgery (AC). Ptotic and large breasts were significantly associated with unfavourable COs and chronic breast oedema. Late toxicities exclusive breast pain were not associated with radiotherapy parameters. (orig.) [German] Ziel dieser Arbeit war es, Parameter zu identifizieren, die Spaetschaeden nach Radiotherapie, ein unguenstiges

  17. Development of model plans in three dimensional conformal radiotherapy for brain tumors

    International Nuclear Information System (INIS)

    Pyo, Hongryull; Kim, Gwieon; Keum, Kichang; Chang, Sekyung; Suh, Changok; Lee, Sanghoon

    2002-01-01

    Three dimensional conformal radiotherapy planning is being used widely for the treatment of patients with brain tumor. However, it takes much time to develop an optimal treatment plan, therefore, it is difficult to apply this technique to all patients. To increase the efficiency of this technique, we need to develop standard radiotherapy plans for each site of the brain. Therefore we developed several 3 dimensional conformal radiotherapy plans (3D plans) for tumors at each site of brain, compared them with each other, and with 2 dimensional radiotherapy plans. Finally model plans for each site of the brain were decided. Imaginary tumors, with sizes commonly observed in the clinic, were designed for each site of the brain and drawn on CT images. The planning target volumes (PTVs) were as follows; temporal tumor-5.7 x 8.2 x 7.6 cm, suprasellar tumor-3 x 4 x 4.1 cm, thalamic tumor-3.1 x 5.9 x 3.7 cm, frontoparietal tumor-5.5 x 7 x 5.5 cm, and occipitoparietal tumor-5 x 5.5 x 5 cm. Plans using parallel opposed 2-portals and/or 3 portals including fronto-vertex and 2 lateral fields were developed manually as the conventional 2D plans, and 3D noncoplanar conformal plans were developed using beam's eye view and the automatic block drawing tool. Total tumor dose was 54 Gy for a suprasellar tumor, 59.4 Gy and 72 Gy for the other tumors. All dose plans (including 2D plans) were calculated using 3D plan software. Developed plans were compared with each other using dose-volume histograms (DVH), normal tissue complication probabilities (NTCP) and variable dose statistic values (minimum, maximum and mean dose, D5, V83, V85 and V95). Finally a best radiotherapy plan for each site of brain was selected. 1) Temporal tumor; NTCPs and DVHs of the normal tissue of all 3D plans were superior to 2D plans and this trend was more definite when total dose was escalated to 72 Gy (NTCPs of normal brain 2D plans: 27%, 8% → 3D plans: 1%, 1%). Various dose statistic values did not show any

  18. Dosimetric tests for treatment planning commissioning in 3DCRT; Testes dosimetricos para comissionamento de sistemas de planejamento em radioterapia 3DCRT

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Leandro R.; Pieri, Karen; Silva, Marco A.; Santos, Gabriela R.; Sales, Camila P.; Rubo, Rodrigo A.; Nakandakari, Marcos V.N.; Cunha, Ana Paula V; Santos, Caroline Z.; Rodrigues, Laura N.; Furnari, Laura, E-mail: leandrorg11@hotmail.com [Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Servico de Radioterapia

    2012-12-15

    The radiotherapy evolution from 2D treatments to 3D conformal treatments was possible after the advent the treatment planning systems commercially available and tridimensional images techniques like computed tomography. These systems have tools that allow delineate anatomical structures from tomographic images. Calculations dose tools allow the planner evaluate the dose received in the anatomical structures. When these systems are acquired or an upgrade is made many dosimetric and non-dosimetric tests need to be performed to know the system limitations and correct functioning and to verify the correct dosimetric data insertion. This study was based in International Atomic Energy Agency protocols, Task Groups documents from American Association of Physics in Medicine, and other papers. A dosimetric test set was done to commissioning the Eclipse 10.0.28 (Varian Medical Systems) treatments planning system This version has two photon calculation algorithm (Pencil Beam Convolution and Analytical Anisotropic Algorithm – AAA) and Gaussian Pencil Beam algorithm for electron beams. However, tests for AAA it was not performed. In this study was possible to conclude that the dosimetric data was correctly added in the treatment planning system. Some results allowed to understand the algorithm limitations to calculate dose distributions in specifics situations, that was not clinically relevant in our routine. (author)

  19. Intensity modulated conformal radiotherapy

    International Nuclear Information System (INIS)

    Noel, Georges; Moty-Monnereau, Celine; Meyer, Aurelia; David, Pauline; Pages, Frederique; Muller, Felix; Lee-Robin, Sun Hae; David, Denis Jean

    2006-12-01

    This publication reports the assessment of intensity-modulated conformal radiotherapy (IMCR). This assessment is based on a literature survey which focussed on indications, efficiency and safety on the short term, on the risk of radio-induced cancer on the long term, on the role in the therapeutic strategy, on the conditions of execution, on the impact on morbidity-mortality and life quality, on the impact on the health system and on public health policies and program. This assessment is also based on the opinion of a group of experts regarding the technical benefit of IMCR, its indications depending on the cancer type, safety in terms of radio-induced cancers, and conditions of execution. Before this assessment, the report thus indicates indications for which the use of IMCR can be considered as sufficient or not determined. It also proposes a technical description of IMCR and helical tomo-therapy, discusses the use of this technique for various pathologies or tumours, analyses the present situation of care in France, and comments the identification of this technique in foreign classifications

  20. Combined Adjuvant Radiochemotherapy With IMRT/XELOX Improves Outcome With Low Renal Toxicity in Gastric Cancer

    International Nuclear Information System (INIS)

    Boda-Heggemann, Judit; Hofheinz, Ralf-Dieter; Weiss, Christel; Mennemeyer, Philipp; Mai, Sabine K.; Hermes, Petra; Wertz, Hansjoerg; Post, Stefan; Massner, Bernd; Hieber, Udo; Hochhaus, Andreas; Wenz, Frederik; Lohr, Frank

    2009-01-01

    Objectives: Adjuvant radiochemotherapy improves survival of patients with advanced gastric cancer. We assessed in two sequential cohorts whether improved radiotherapy technique (IMRT) together with intensified chemotherapy improves outcome vs. conventional three-dimensional conformal radiotherapy (3D-CRT) and standard chemotherapy in these patients while maintaining or reducing renal toxicity. Materials and Methods: Sixty consecutive patients treated for gastric cancer either with 3D-CRT (n = 27) and IMRT (n = 33) were evaluated. More than 70% had undergone D2 resection. Although there was a slight imbalance in R0 status between cohorts, N+ status was balanced. Chemotherapy consisted predominantly of 5-fluorouracil/folinic acid (n = 36) in the earlier cohort and mostly of oxaliplatin/capecitabine (XELOX, n = 24) in the later cohort. Primary end points were overall survival (OS), disease-free survival (DFS), and renal toxicity based on creatinine levels. Results: Median follow-up (FU) of all patients in the 3D-CRT group was 18 months and in the IMRT group 22 months (median FU of surviving patients 67 months in the 3D-CRT group and 25 months in the IMRT group). Overall median survival (and DFS) were 18 (13) months in the 3D-CRT group and both not reached in the IMRT group (p = 0.0492 and 0.0216). Actuarial 2-year survival was 37% and 67% in the 3D-CRT and IMRT groups, respectively. No late renal toxicity >Grade 2 (LENT-SOMA scale) was observed in either cohort. Conclusion: When comparing sequentially treated patient cohorts with similar characteristics, OS and DFS improved with the use of IMRT and intensified chemotherapy without signs of increased renal toxicity.

  1. Patient repositioning in prostate conformal radiotherapy by image fusion

    International Nuclear Information System (INIS)

    Betrouni, Nacim

    2004-01-01

    This research thesis first proposes an overview of imaging modalities which are generally used in radiotherapy, and briefly presents operation principles for ultrasound scans, scanners and MRI. The issue of patient repositioning in radiotherapy is then introduced, and already proposed solutions are presented. In the next part, the author addresses space location and ultrasound-based location, with a brief overview of methods used to track the displacements of a mobile object, in this case an ultrasound probe, and calibration. Then, after a presentation of the adopted method, and a discussion of published works related to contour extraction and to filtering and noise reduction methods in ultrasound imagery, the author addresses the issue of prostate segmentation based on ultrasound images. The next part deals with image registration with an overview of available methods and tools. A method of registration of pre-operation images obtained by MRI or scanner, and of intra-operation ultrasound images is proposed for a real-time registration. This method is aimed at supporting patient repositioning during prostate conformal radiotherapy

  2. Conformal intensity-modulated radiotherapy (IMRT) delivered by robotic linac-conformality versus efficiency of dose delivery

    International Nuclear Information System (INIS)

    Webb, Steve

    2000-01-01

    Intensity-modulated radiotherapy (IMRT) may be delivered with a high-energy-photon linac mounted on a robotic gantry and executing a complex trajectory. In a previous paper an inverse-planning technique was developed for such an application. Here the work is extended to demonstrate the dependence of conformality on the size of the elemental pencil beam, on the complexity of the trajectory and on the sampling of azimuth and elevation of the collimated source. The improved conformality of complex trajectories is demonstrated and benchmarked relative to simpler trajectories, more representative of existing non-robotic IMRT techniques. Specifically, by choosing a very fine pencil beam, exquisitely conformal dose distributions have been obtained. Important sampling considerations have been determined. Expressions have been derived for the dosimetry and monitor-unit efficiency of robotic IMRT. Equivalent trajectories were computed for executing the complex robotic trajectories instead by using a conventional linac. The work benchmarks an ideal in IMRT against which more practical and more common techniques may be measured. (author)

  3. Brainstem tolerance to conformal radiotherapy of skull base tumors

    International Nuclear Information System (INIS)

    Debus, J.; Hug, E.B.; Liebsch, N.J.; O'Farrel, D.; Finkelstein, D.; Efird, J.; Munzenrider, J.E.

    1997-01-01

    Purpose: The aim of this study was to analyze the long-term incidence of brainstem toxicity in patients treated for skull base tumors with high dose conformal radiotherapy. Methods and Materials: Between 1974 and 1995, 367 patients with chordomas (n = 195) and chondrosarcomas (n = 172) of the base of skull have been treated with combined megavoltage photon and 160 MeV proton radiotherapy. Following 3D treatment planning with delineation of target volumes and critical nontarget structures dose distributions and dose-volume histograms were calculated. Radiotherapy was given an 1.8 Gy or CGE (=Cobalt Gray Equivalent) dose per fraction, with prescribed target doses ranging from 63 CGE to 79.2 CGE (mean = 67.8 CGE). Doses to the brainstem surface were limited to ≤64 CGE and to the brainstem center to ≤53 CGE. Results: Follow-up time ranged from 6 months to 21.4 years (mean = 42.5 months). Brainstem toxicity was observed in 17 of 367 patients attributable to treatment, resulting in death of three patients. Actuarial rates of 5 and 10-year high-grade toxicity-free survival were 94 and 88%, respectively. Increased risk of brainstem toxicity was significantly associated with maximum dose to brainstem, volume of brainstem receiving ≥50 CGE, ≥55 CGE, and ≥60 CGE, number of surgical procedures, and prevalence of diabetes or high blood pressure. Multivariate analysis identified three independent factors as important prognosticators: number of surgical procedures (p < 0.001), volume of the brainstem receiving 60 CGE (p < 0.001), and prevalence of diabetes (p < 0.01). Conclusions: Tolerance of brainstem to fractionated radiotherapy appears to be a steep function of tissue volume included in high dose regions rather than the maximum dose of brainstem alone. In addition, presence of predisposing factors as well as extent of surgical manipulation can significantly lower brainstem tolerance in the individual patient

  4. Preservation of parotid function with uncomplicated conformal radiotherapy

    International Nuclear Information System (INIS)

    Maes, Annelies; Weltens, Caroline; Flamen, Patrick; Lambin, Philippe; Bogaerts, Ria; Liu, Xuan; Baetens, Jan; Hermans, Robert; Van den Bogaert, Walter

    2002-01-01

    Background and purpose: To evaluate (1) parotid function, (2) subjective xerostomia and (3) pattern of relapses after conformal parotid-sparing radiotherapy (RT) for head and neck cancer. (4) To study dose-response curves of parotid glands. Material and methods: From September 1999 to November 2000, 39 head and neck cancer patients requiring bilateral neck RT were treated with a fairly simple conformal RT technique (three-field set-up+anterior lower neck field; two opposed oblique boost fields). The contralateral parotid was spared. Parotid function was assessed by salivary gland scintigraphies performed before, early (median 4 weeks) and late (median 28 weeks) after RT. Xerostomia was monitored by visual analogue scales (VAS) and LENT SOMA scores. Location of locoregional recurrences was studied in relation to the radiation fields. A dose-response curve of parotids was created using logistic regression. Results: (1) Early after RT, on salivary gland scintigraphy, the mean loss of secretion function in the spared parotid was 67% and total in the non-spared. Late after RT, the mean loss remained 19% in the spared and total in the non-spared parotid. Normal excretion function was regained in 75% of the spared parotids. (2) Late after RT, 78% of patients had no, minimal or acceptable subjective xerostomia. (3) No recurrence was seen near the spared parotid (11/39 locoregional recurrences). (4) The dose-response curve of parotids showed that the mean parotid dose should preferentially be ≤20 Gy, to obtain a good chance (≥70%) for preservation of its function on scintigraphy. Conclusions: An easy conformal parotid-sparing RT technique prevents moderate or severe subjective xerostomia in 78% of patients. In the spared parotids, nearly complete to complete recovery is obtained after 6-12 months

  5. Conformal radiotherapy by intensity modulation of pediatrics tumors

    International Nuclear Information System (INIS)

    Leseur, J.; Le Prise, E.; Carrie, C.; Bernier, V.; Beneyton, V.; Mahe, M.A.; Supiot, S.

    2009-01-01

    The objective of this study is to take stock on the validated and potential indications of the conformal radiotherapy with intensity modulation ( intensity modulated radiotherapy I.M.R.T.) in pediatrics and to propose recommendations for its use as well as the adapted dose constraints. About 40 to 50% of children treated for a cancer are irradiated. The I.M.R.T., by linear accelerator or helical tomo-therapy has for aim to give a homogenous dose to the target volume and to save organs at risk. Its use in pediatrics seems particularly interesting because of the complexity of target volumes and the closeness of organs at risk. In compensation for these positive elements, the importance of low doses irradiation given in big volumes makes fear event consequences on growth and an increased incidence of secondary cancers in children suffering from tumors with high cure rates and long life expectancy. (N.C.)

  6. Nasopharynx carcinoma treatment: from the conventional radiotherapy to the conformal radiotherapy with intensity modulation; Traitement du carcinome du nasopharynx: de la radiotherapie conventionnelle a la radiotherapie conformationnelle avec modulation d'intensite

    Energy Technology Data Exchange (ETDEWEB)

    Mokaouim, K.; Grehange, G.; Truc, G.; Peingnaux, K.; Martin, E.; Zanetta, S.; Bruchon, Y.; Bonnetain, F.; Maingon, P. [Centre Georges-Francois Leclerc, 21 - Dijon (France)

    2009-10-15

    The objective of this study was to evaluate retrospectively the impact of factors linked to the radiotherapy realisation on the local and locoregional control, the global survival, the survival without disease of patients suffering of naso-pharynx carcinoma. Conclusion: the patients suffering of a nasopharynx carcinoma treated by irradiation associated to chemotherapy have an improved global survival and an improved survival without disease. The conformal radiotherapy with or without modulated intensity reduce the risk of serous otitis, trismus and xerostomia at long term. It seems necessary to realize multi centric studies with a longer period of follow up before asserting the advantages of the I.M.R.T. in comparison to the classical and conformal technique in the treatment of naso-pharynx carcinomas. (N.C.)

  7. Continuous Arc Rotation of the Couch Therapy for the Delivery of Accelerated Partial Breast Irradiation: A Treatment Planning Analysis

    International Nuclear Information System (INIS)

    Shaitelman, Simona F.; Kim, Leonard H.; Yan Di; Martinez, Alvaro A.; Vicini, Frank A.; Grills, Inga S.

    2011-01-01

    Purpose: We present a novel form of arc therapy: continuous arc rotation of the couch (C-ARC) and compare its dosimetry with three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT) for accelerated partial breast irradiation (APBI). C-ARC, like VMAT, uses a modulated beam aperture and dose rate, but with the couch, not the gantry, rotating. Methods and Materials: Twelve patients previously treated with APBI using 3D-CRT were replanned with (1) C-ARC, (2) IMRT, and (3) VMAT. C-ARC plans were designed with one medial and one lateral arc through which the couch rotated while the gantry was held stationary at a tangent angle. Target dose coverage was normalized to the 3D-CRT plan. Comparative endpoints were dose to normal breast tissue, lungs, and heart and monitor units prescribed. Results: Compared with 3D-CRT, C-ARC, IMRT, and VMAT all significantly reduced the ipsilateral breast V50% by the same amount (mean, 7.8%). Only C-ARC and IMRT plans significantly reduced the contralateral breast maximum dose, the ipsilateral lung V5Gy, and the heart V5%. C-ARC used on average 40%, 30%, and 10% fewer monitor units compared with 3D-CRT, IMRT, and VMAT, respectively. Conclusions: C-ARC provides improved dosimetry and treatment efficiency, which should reduce the risks of toxicity and secondary malignancy. Its tangent geometry avoids irradiation of critical structures that is unavoidable using the en face geometry of VMAT.

  8. Pancreatic cancer planning: Complex conformal vs modulated therapies

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Katherine L. [Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Witek, Matthew E. [Department of Radiation Oncology, University of Wisconsin School of Medicine School of Medicine and Public Health, Madison, WI (United States); Chen, Hongyu [Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Showalter, Timothy N. [Department of Radiation Oncology, University of Virginia, Charlottesville, VA (United States); Bar-Ad, Voichita [Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Harrison, Amy S., E-mail: amy.harrison@jefferson.edu [Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA (United States)

    2016-07-01

    To compare the roles of intensity-modulated radiation therapy (IMRT) and volumetric- modulated arc therapy (VMAT) therapy as compared to simple and complex 3-dimensional chemoradiotherpy (3DCRT) planning for resectable and borderline resectable pancreatic cancer. In all, 12 patients who received postoperative radiotherapy (8) or neoadjuvant concurrent chemoradiotherapy (4) were evaluated retrospectively. Radiotherapy planning was performed for 4 treatment techniques: simple 4-field box, complex 5-field 3DCRT, 5 to 6-field IMRT, and single-arc VMAT. All volumes were approved by a single observer in accordance with Radiation Therapy Oncology Group (RTOG) Pancreas Contouring Atlas. Plans included tumor/tumor bed and regional lymph nodes to 45 Gy; with tumor/tumor bed boosted to 50.4 Gy, at least 95% of planning target volume (PTV) received the prescription dose. Dose-volume histograms (DVH) for multiple end points, treatment planning, and delivery time were assessed. Complex 3DCRT, IMRT, and VMAT plans significantly (p < 0.05) decreased mean kidney dose, mean liver dose, liver (V{sub 30}, V{sub 35}), stomach (D{sub 10}%), stomach (V{sub 45}), mean right kidney dose, and right kidney (V{sub 15}) as compared with the simple 4-field plans that are most commonly reported in the literature. IMRT plans resulted in decreased mean liver dose, liver (V{sub 35}), and left kidney (V{sub 15}, V{sub 18}, V{sub 20}). VMAT plans decreased small bowel (D{sub 10}%, D{sub 15}%), small bowel (V{sub 35}, V{sub 45}), stomach (D{sub 10}%, D{sub 15}%), stomach (V{sub 35}, V{sub 45}), mean liver dose, liver (V{sub 35}), left kidney (V{sub 15}, V{sub 18}, V{sub 20}), and right kidney (V{sub 18}, V{sub 20}). VMAT plans significantly decreased small bowel (D{sub 10}%, D{sub 15}%), left kidney (V{sub 20}), and stomach (V{sub 45}) as compared with IMRT plans. Treatment planning and delivery times were most efficient for simple 4-field box and VMAT. Excluding patient setup and imaging, average

  9. Prostate and seminal vesicle volume based consideration of prostate cancer patients for treatment with 3D-conformal or intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Reddy, Nandanuri M. S.; Nori, Dattatreyudu; Chang, Hyesook; Lange, Christopher S.; Ravi, Akkamma

    2010-01-01

    Purpose: The purpose of this article was to determine the suitability of the prostate and seminal vesicle volumes as factors to consider patients for treatment with image-guided 3D-conformal radiation therapy (3D-CRT) or intensity-modulated radiation therapy (IMRT), using common dosimetry parameters as comparison tools. Methods: Dosimetry of 3D and IMRT plans for 48 patients was compared. Volumes of prostate, SV, rectum, and bladder, and prescriptions were the same for both plans. For both 3D and IMRT plans, expansion margins to prostate+SV (CTV) and prostate were 0.5 cm posterior and superior and 1 cm in other dimensions to create PTV and CDPTV, respectively. Six-field 3D plans were prepared retrospectively. For 3D plans, an additional 0.5 cm margin was added to PTV and CDPTV. Prescription for both 3D and IMRT plans was the same: 45 Gy to CTV followed by a 36 Gy boost to prostate. Dosimetry parameters common to 3D and IMRT plans were used for comparison: Mean doses to prostate, CDPTV, SV, rectum, bladder, and femurs; percent volume of rectum and bladder receiving 30 (V30), 50 (V50), and 70 Gy (V70), dose to 30% of rectum and bladder, minimum and maximum point dose to CDPTV, and prescription dose covering 95% of CDPTV (D95). Results: When the data for all patients were combined, mean dose to prostate and CDPTV was higher with 3D than IMRT plans (P 0.2). On average, among all cases, the minimum point dose was less for 3D-CRT plans and the maximum point dose was greater for 3D-CRT than for IMRT (P 0.1). V30 was less (P 0.2), and V70 was more (P 0.2). Mean dose to femurs was more with 3D than IMRT plans (P 3 (39/48), respectively (P 3 , respectively, would be suitable for 3D-CRT. Patients with prostate and prostate+SV volumes >65 and 85 cm 3 , respectively, might get benefit from IMRT.

  10. Toxicity and cosmetic outcome of three-dimensional conformal radiotherapy for accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Gatti, M.; Bresciani, S.; Ponzone, R.; Panaia, R.; Salatino, A.; Stasi, M.; Gabriele, P.

    2011-01-01

    Full text of publication follows: Purpose.- To analyse the incidence and severity of acute and late normal tissue toxicity and cosmetic outcome using three - dimensional conformal radiotherapy to deliver accelerated partial breast irradiation. Patients and Methods.- 70 patients with stage I disease were treated with three-dimensional conformal radiotherapy for accelerated partial breast irradiation, in an approved protocol. The prescribed dose was 34 Gy in all patients delivered in 10 fractions over 5 consecutive days. On all CT scans gross tumor volume (GTV ) was defined around surgical clips. A 1.5 cm margin was added in order to account for clinical target volume (CTV) . A margin of 1 cm was added to CTI to define the planning target volume (PTV). The dose-volume constraints were followed in accordance with the specifications as dictated in the NSABP/RTOG protocol. After treatment, patients underwent a clinical and cosmetic evaluation every 3 months. Late toxicity was evaluated according to the RTOG grading schema. The cosmetic assessment was performed by the physicians using the controlateral untreated breast as the reference (Harvard scale). Results.- Median patient age was 66 years (range 51-80). Median follow-up was 15 months (range 6-46). Tumor size was 2 cm in 4(6%). The mean value of the ratio between the PTV and the whole ipsilateral breast volume was 38 % and the median percentage whole breast volume that received 95 % of prescribed dose was 34% (range 16%-55%). The rate of G1 and G2 acute skin toxicity was 28% and 2% respectively and the late toxicity was 17% (G1). G2 or greater toxicities were not observed. The most pronounced G1 late toxicity was subcutaneous fibrosis, developed in 3 patients. The cosmetic outcome was excellent in 83% and good in 17%. Conclusion.- Accelerated partial breast irradiation using three-dimensional conformal radiotherapy is technically feasible with very low acute and late toxicity. Long-term results are needed to assess

  11. Accuracy of Real-time Couch Tracking During 3-dimensional Conformal Radiation Therapy, Intensity Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Wilbert, Juergen; Baier, Kurt; Hermann, Christian; Flentje, Michael; Guckenberger, Matthias

    2013-01-01

    Purpose: To evaluate the accuracy of real-time couch tracking for prostate cancer. Methods and Materials: Intrafractional motion trajectories of 15 prostate cancer patients were the basis for this phantom study; prostate motion had been monitored with the Calypso System. An industrial robot moved a phantom along these trajectories, motion was detected via an infrared camera system, and the robotic HexaPOD couch was used for real-time counter-steering. Residual phantom motion during real-time tracking was measured with the infrared camera system. Film dosimetry was performed during delivery of 3-dimensional conformal radiation therapy (3D-CRT), step-and-shoot intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Results: Motion of the prostate was largest in the anterior–posterior direction, with systematic (∑) and random (σ) errors of 2.3 mm and 2.9 mm, respectively; the prostate was outside a threshold of 5 mm (3D vector) for 25.0%±19.8% of treatment time. Real-time tracking reduced prostate motion to ∑=0.01 mm and σ = 0.55 mm in the anterior–posterior direction; the prostate remained within a 1-mm and 5-mm threshold for 93.9%±4.6% and 99.7%±0.4% of the time, respectively. Without real-time tracking, pass rates based on a γ index of 2%/2 mm in film dosimetry ranged between 66% and 72% for 3D-CRT, IMRT, and VMAT, on average. Real-time tracking increased pass rates to minimum 98% on average for 3D-CRT, IMRT, and VMAT. Conclusions: Real-time couch tracking resulted in submillimeter accuracy for prostate cancer, which transferred into high dosimetric accuracy independently of whether 3D-CRT, IMRT, or VMAT was used.

  12. Conformal radiotherapy for prostate cancer: contribution of pelvic immobilization and new fiducial markers

    International Nuclear Information System (INIS)

    Garcia, R.; Oozeer, R.; Le Thanh, H.; Chauvet, B.; Toy, B.J.; Reboul, F.

    1997-01-01

    To reduce errors in the positioning of patients treated with external conformal radiotherapy for prostate cancer, we evaluated both the use of an immobilization device and new fiducial markers. The immobilization device consisted of an individual mold made of polyurethane foam. Two sets of skin markers located on the anterior tibial surfaces were used to identify the pelvic isocenter. The patient's position was evaluated by orthogonal port film which were then compared with the original simulation film. Results are presented with respect to orthogonal axes. Comparison with classic procedures without immobilization showed that use of the mold and new fiducial markers led to a decrease in set-up errors which were less than 5 mm. With the use of an immobilization device and optimized techniques for patients' positioning, conformal radiotherapy of prostate cancer is more accurate. (authors)

  13. The quality assurance process for the ARTSCAN head and neck study - A practical interactive approach for QA in 3DCRT and IMRT

    International Nuclear Information System (INIS)

    Johansson, Karl-Axel; Nilsson, Per; Zackrisson, Bjoern; Ohlson, Birgitta; Kjellen, Elisabeth; Mercke, Claes; Alvarez-Fonseca, Mauricio; Billstroem, Anette; Bjoerk-Eriksson, Thomas; Bjoer, Ove; Ekberg, Lars; Friesland, Signe; Karlsson, Magnus; Lagerlund, Magnus; Lundkvist, Lena; Loefroth, Per-Olov; Loefvander-Thapper, Kerstin; Nilsson, Alla; Nyman, Jan; Persson, Essie

    2008-01-01

    Aim: This paper describes the quality assurance (QA) work performed in the Swedish multicenter ARTSCAN (Accelerated RadioTherapy of Squamous cell CArcinomas in the head and Neck) trial to guarantee high quality in a multicenter study which involved modern radiotherapy such as 3DCRT or IMRT. Materials and methods: The study was closed in June 2006 with 750 randomised patients. Radiation therapy-related data for every patient were sent by each participating centre to the QA office where all trial data were reviewed, analysed and stored. In case of any deviation from the protocol, an interactive process was started between the QA office and the local responsible clinician and/or physicist to increase the compliance to the protocol for future randomised patients. Meetings and workshops were held on a regular basis for discussions on various trial-related issues and for the QA office to report on updated results. Results and discussion: This review covers the 734 patients out of a total of 750 who had entered the study. Deviations early in the study were corrected so that the overall compliance to the protocol was very high. There were only negligible variations in doses and dose distributions to target volumes for each specific site and stage. The quality of the treatments was high. Furthermore, an extensive database of treatment parameters was accumulated for future dose-volume vs. endpoint evaluations. Conclusions: This comprehensive QA programme increased the probability to draw firm conclusions from our study and may serve as a concept for QA work in future radiotherapy trials where comparatively small effects are searched for in a heterogeneous tumour population

  14. A neurosurgery/stereotactic radiotherapy dedicated PACS for conformal radiotherapy

    International Nuclear Information System (INIS)

    Lefkopoulos, D.; Bocquiault, P.; Levrier, M.; Merienne, L.; Schlienger, M.

    1995-01-01

    To realise conformal cerebral stereotactic irradiations we use a Neurosurgery/stereotactic dedicated PACS between two distant hospitals. It connects the stereotactic neurosurgery planification imaging system NEUROAXIS (Sopelem-Sofretec/Ste Anne Hospital) with the dosimetric TPS ARTEMIS-3D/Dosigray (Tenon Hospital). NEUROAXIS is a computer aided stereotactic biopsies and stereo-electroencephalographies, used by surgeons in operating room. The system determines the precise location data for Talairach radiological equipment (X ray source at 5 meters from film) and the geometry of scanner and MRI stereotactical referentials. It provides a full set of features for lesion localization, geometrical computations, surgical planifications, picture archiving, stereotactic angiography, CT and MRI image processing and networking. It sends images through the French public digital network ISDN (NUMERIS/France Telecom : 2x64 Kbits/s) from Ste Anne to Tenon Hospital. Stereotactic angiographic and CT images are reformatted into the DOSIGRAY image processing environment where 3-D dose distributions, displays and DVHs are computed to determine the optimal treatment. ARTEMIS-3D/Dosigray is a TPS for stereotactic radiotherapy devised by the Tenon Hospital for clinical methodology and 3D dose calculations, optimization software development and the Dosigray company for multimodality imaging, (2D(3D)) computer graphics for dose and anatomical representation and data networking. Communication within the radiation oncology department is provided by local area ETHERNET network, linking heterogeneous systems (Vaxstations-3200; Decstation (5000(240))) by means of different protocols. The works in progress are to send back via the same network the 3-D dose matrix to Neurosurgery department NEUROAXIS system. Our PACS is used since six months to treat patients. It has permitted to improve the treatment quality in comparison with our first version TPS ARTEMIS-3D

  15. Prediction of radiation-induced liver disease by Lyman normal-tissue complication probability model in three-dimensional conformal radiation therapy for primary liver carcinoma

    International Nuclear Information System (INIS)

    Xu ZhiYong; Liang Shixiong; Zhu Ji; Zhu Xiaodong; Zhao Jiandong; Lu Haijie; Yang Yunli; Chen Long; Wang Anyu; Fu Xiaolong; Jiang Guoliang

    2006-01-01

    Purpose: To describe the probability of RILD by application of the Lyman-Kutcher-Burman normal-tissue complication (NTCP) model for primary liver carcinoma (PLC) treated with hypofractionated three-dimensional conformal radiotherapy (3D-CRT). Methods and Materials: A total of 109 PLC patients treated by 3D-CRT were followed for RILD. Of these patients, 93 were in liver cirrhosis of Child-Pugh Grade A, and 16 were in Child-Pugh Grade B. The Michigan NTCP model was used to predict the probability of RILD, and then the modified Lyman NTCP model was generated for Child-Pugh A and Child-Pugh B patients by maximum-likelihood analysis. Results: Of all patients, 17 developed RILD in which 8 were of Child-Pugh Grade A, and 9 were of Child-Pugh Grade B. The prediction of RILD by the Michigan model was underestimated for PLC patients. The modified n, m, TD 5 (1) were 1.1, 0.28, and 40.5 Gy and 0.7, 0.43, and 23 Gy for patients with Child-Pugh A and B, respectively, which yielded better estimations of RILD probability. The hepatic tolerable doses (TD 5 ) would be MDTNL of 21 Gy and 6 Gy, respectively, for Child-Pugh A and B patients. Conclusions: The Michigan model was probably not fit to predict RILD in PLC patients. A modified Lyman NTCP model for RILD was recommended

  16. Has 3-D conformal radiotherapy (3D CRT) improved the local tumour control for stage I non-small cell lung cancer?

    International Nuclear Information System (INIS)

    Lagerwaard, Frank J.; Senan, Suresh; Meerbeeck, Jan P. van; Graveland, Wilfried J.

    2002-01-01

    Aims and background: The high local failure rates observed after radiotherapy in stage I non-small cell lung cancer (NSCLC) may be improved by the use of 3-dimensional conformal radiotherapy (3D CRT). Materials and methods: The case-records of 113 patients who were treated with curative 3D CRT between 1991 and 1999 were analysed. No elective nodal irradiation was performed, and doses of 60 Gy or more, in once-daily fractions of between 2 and 3 Gy, were prescribed. Results: The median actuarial survival of patients was 20 months, with 1-, 3- and 5-year survival of 71, 25 and 12%, respectively. Local disease progression was the cause of death in 30% of patients, and 22% patients died from distant metastases. Grade 2-3 acute radiation pneumonitis (SWOG) was observed in 6.2% of patients. The median actuarial local progression-free survival (LPFS) was 27 months, with 85 and 43% of patients free from local progression at 1 and 3 years, respectively. Endobronchial tumour extension significantly influenced LPFS, both on univariate (P=0.023) and multivariate analysis (P=0.023). The median actuarial cause-specific survival (CSS) was 19 months, and the respective 1- and 3-year rates were 72 and 30%. Multivariate analysis showed T2 classification (P=0.017) and the presence of endobronchial tumour extension (P=0.029) to be adverse prognostic factors for CSS. On multivariate analysis, T-stage significantly correlated with distant failure (P=0.005). Conclusions: Local failure rates remain substantial despite the use of 3D CRT for stage I NSCLC. Additional improvements in local control can come about with the use of radiation dose escalation and approaches to address the problem of tumour mobility

  17. Initial dosimetric experience using simple three-dimensional conformal external-beam accelerated partial-breast irradiation

    International Nuclear Information System (INIS)

    Taghian, Alphonse G.; Kozak, Kevin R.; Doppke, Karen P.; Katz, Angela; Smith, Barbara L.; Gadd, Michele; Specht, Michelle; Hughes, Kevin; Braaten, Kristina; Kachnic, Lisa A.; Recht, Abram; Powell, Simon N.

    2006-01-01

    Purpose: Several accelerated partial-breast irradiation (APBI) techniques are being investigated in patients with early-stage breast cancer. We present our initial experience using three-dimensional conformal radiation therapy (3D-CRT). Methods and Materials: Sixty-one patients with tumors of 2 cm or less and negative axillary nodes were treated with 3D-CRT accelerated partial-breast irradiation (APBI) between August 2003 and March 2005. The prescribed radiation dose was 32 Gy in 4-Gy fractions given twice daily. Efforts were made to minimize the number of beams required to achieve adequate planning target volume (PTV) coverage. Results: A combination of photons and electrons was used in 85% of patients. A three-field technique that consisted of opposed, conformal tangential photons and enface electrons was employed in 43 patients (70%). Nine patients (15%) were treated with a four-field arrangement, which consisted of three photon fields and enface electrons. Mean PTV volumes that received 100%, 95%, and 90% of the prescribed dose were 93% ± 7%, 97% ± 4%, and 98% ± 2%, respectively. Dose inhomogeneity exceeded 10% in only 7 patients (11%). Mean doses to the ipsilateral lung and heart were 1.8 Gy and 0.8 Gy, respectively. Conclusions: Simple 3D-CRT techniques of APBI can achieve appropriate PTV coverage while offering significant normal-tissue sparing. Therefore, this noninvasive approach may increase the availability of APBI to patients with early-stage breast cancer

  18. Independent dose calculation of the Tps Iplan in radiotherapy conformed with MLC

    International Nuclear Information System (INIS)

    Adrada, A.; Tello, Z.; Medina, L.; Garrigo, E.; Venencia, D.

    2014-08-01

    The systems utilization of independent dose calculation in three dimensional-Conformal Radiation Therapy (3D-Crt) treatments allows a direct verification of the treatments times. The utilization of these systems allows diminishing the probability of errors occurrence generated by the treatment planning system (Tps), allowing a detailed analysis of the dose to delivering and review of the normalization point (Np) or prescription. The independent dose calculation is realized across the knowledge of dosimetric parameters of the treatment machine and particular characteristics of every individual field. The aim of this work is develops a calculation system of punctual doses for isocentric fields conformed with multi-leaf collimation systems (MLC), where the dose calculation is in conformity with the suggested ones by ICRU Report No. 42, 1987. Calculation software was realized in C ++ under a free platform of programming (Code::Blocks). The system uses files in format Rtp, exported from the Tps to systems of record and verification (Lantis). This file contains detailed information of the dose, Um, position of the MLC sheets and collimators for every field of treatment. The size of equivalent field is obtained from the positions of every sheet; the effective depth of calculation can be introduced from the dosimetric report of the Tps or automatically from the DFS of the field. The 3D coordinates of the isocenter and the Np for the treatment plan must be introduced manually. From this information the system looks the dosimetric parameters and calculates the Um. The calculations were realized in two accelerators a NOVALIS Tx (Varian) with 120 sheets of high definition (hd-MLC) and a PRIMUS Optifocus (Siemens) with 82 sheets. 705 patients were analyzed for a total of 1082, in plans made for both equipment s, the average uncertainty with regard to the calculation of the Tps is-0.43% ± 2.42% in a range between [-7.90 %, 7.50 %]. The major uncertainty was in Np near of the

  19. Nomogram to predict rectal toxicity following prostate cancer radiotherapy.

    Directory of Open Access Journals (Sweden)

    Jean-Bernard Delobel

    Full Text Available To identify predictors of acute and late rectal toxicity following prostate cancer radiotherapy (RT, while integrating the potential impact of RT technique, dose escalation, and moderate hypofractionation, thus enabling us to generate a nomogram for individual prediction.In total, 972 patients underwent RT for localized prostate cancer, to a total dose of 70 Gy or 80 Gy, using two different fractionations (2 Gy or 2.5 Gy/day, by means of several RT techniques (3D conformal RT [3DCRT], intensity-modulated RT [IMRT], or image-guided RT [IGRT]. Multivariate analyses were performed to identify predictors of acute and late rectal toxicity. A nomogram was generated based on the logistic regression model used to predict the 3-year rectal toxicity risk, with its accuracy assessed by dividing the cohort into training and validation subgroups.Mean follow-up for the entire cohort was 62 months, ranging from 6 to 235. The rate of acute Grade ≥2 rectal toxicity was 22.2%, decreasing when combining IMRT and IGRT, compared to 3DCRT (RR = 0.4, 95%CI: 0.3-0.6, p<0.01. The 5-year Grade ≥2 risks for rectal bleeding, urgency/tenesmus, diarrhea, and fecal incontinence were 9.9%, 4.5%, 2.8%, and 0.4%, respectively. The 3-year Grade ≥2 risk for overall rectal toxicity increased with total dose (p<0.01, RR = 1.1, 95%CI: 1.0-1.1 and dose per fraction (2Gy vs. 2.5Gy (p = 0.03, RR = 3.3, 95%CI: 1.1-10.0, and decreased when combining IMRT and IGRT (RR = 0.50, 95% CI: 0.3-0.8, p<0.01. Based on these three parameters, a nomogram was generated.Dose escalation and moderate hypofractionation increase late rectal toxicity. IMRT combined with IGRT markedly decreases acute and late rectal toxicity. Performing combined IMRT and IGRT can thus be envisaged for dose escalation and moderate hypofractionation. Our nomogram predicts the 3-year rectal toxicity risk by integrating total dose, fraction dose, and RT technique.

  20. Conformal radiotherapy in the adjuvant treatment of gastric cancer: Review of 82 cases

    International Nuclear Information System (INIS)

    Kassam, Zahra; Lockwood, Gina; O'Brien, Catherine; Brierley, James; Swallow, Carol; Oza, Amit; Siu, Lillian; Knox, Jennifer J.; Wong, Rebecca; Cummings, Bernard; Kim, John; Moore, Malcolm; Ringash, Jolie

    2006-01-01

    Background: The Intergroup 0116 study showed a survival benefit with adjuvant chemoradiotherapy (CRT) for resected gastric cancer. We report our experience using conformal radiotherapy (RT). Methods and Materials: Eighty-two patients with resected gastric or gastroesophageal junction (GEJ) adenocarcinoma, Stage IB to IV (M0), were treated with 45 Gy in 25 fractions using a 5-field conformal technique. Chemotherapy was in accordance with the Intergroup 0116 study, or infusional 5-fluorouracil and cisplatin in a phase I/II trial. Results: Mean age was 56.4 years. Median follow-up was 22.8 months. Grade 3 or greater acute toxicity (National Cancer Institute Common Terminology Criteria of Adverse Events, version 3.0) was noted in 57% of patients (upper gastrointestinal tract 34%, hematologic 33%). One patient died of neutropenic sepsis. Radiation Therapy Oncology Group Grade 3 late toxicity included esophageal strictures (3 patients) and small bowel obstruction (1 patient). Full course CRT was completed by 67% of patients. Of 26 patients who relapsed, 20 died. Site of first relapse was available on 23 patients: 8 locoregional and distant, 4 locoregional alone, 11 distant alone. Overall and relapse-free survival were 69% and 54% at 3 years. Conclusion: Adjuvant CRT for gastric cancer, even with conformal RT, is associated with significant toxicity. Survival was comparable to that reported in the Intergroup 0116 study

  1. The treatment of nonpalpable PSA-detected adenocarcinoma of the prostate with 3-dimensional conformal radiation therapy

    International Nuclear Information System (INIS)

    Horwitz, Eric M.; Hanlon, Alexandra L.; Pinover, Wayne H.; Hanks, Gerald E.

    1998-01-01

    Purpose: We reviewed our institution's experience treating patients with nonpalpable PSA-detected prostate cancer with three-dimensional conformal radiation therapy (3DCRT) to determine prognostic factors that predict for biochemical-free survival (bNED) control and present the bNED control rates. Methods and Materials: Between May 1, 1990 and November 30, 1994, 160 patients with nonpalpable PSA-detected prostate cancer received 3DCRT at Fox Chase Cancer Center (median total dose 73 Gy; range: 67-78 Gy). bNED failure was defined as three consecutive increases in posttreatment PSA after achieving a nadir. bNED failure was recorded as the time midway between the nadir and the first consecutive rising PSA. Five-year actuarial rates of bNED control were calculated for pretreatment PSA (0-9.9 vs. 10-19.9 vs. ≥ 20 ng/ml), Gleason score (2-6 vs. 7-10), treatment field size (prostate vs. small pelvis), age ( 73 Gy) using Kaplan-Meier methods and compared using the Log rank test. The Cox model was used to multivariately establish independent predictors based on significant univariate factors. Median follow-up was 39 months (range: 2-84 months). Results: The 5-year actuarial rate of bNED control was 86% for the entire group of patients. The Cox Proportional Hazards model demonstrated that pretreatment PSA was an independent predictor of bNED control. Treatment field size was marginally predictive. There was no difference in bNED control when patients were stratified by the number of lobes positive for disease. Statistically different rates of bNED control were seen when the patients with nonpalpable disease were univariately compared to T2b and T2c patients. Three patients experienced Grade 3-4 genitourinary (GU) toxicity and 3 patients experienced Grade 3-4 gastrointestinal (GI) toxicity. Conclusions: Patients with nonpalpable PSA-detected prostate cancer can be effectively treated with 3DCRT with minimal morbidity and high rates of bNED control at 5 years. Pretreatment

  2. Quality indicators for prostate radiotherapy: are patients disadvantaged by receiving treatment in a 'generalist' centre?

    Science.gov (United States)

    Freeman, Amanda R; Roos, Daniel E; Kim, Laurence

    2015-04-01

    The purpose of this retrospective review was to evaluate concordance with evidence-based quality indicator guidelines for prostate cancer patients treated radically in a 'generalist' (as distinct from 'sub-specialist') centre. We were concerned that the quality of treatment may be lower in a generalist centre. If so, the findings could have relevance for many radiotherapy departments that treat prostate cancer. Two hundred fifteen consecutive patients received external beam radiotherapy (EBRT) and/or brachytherapy between 1.10.11 and 30.9.12. Treatment was deemed to be in line with evidence-based guidelines if the dose was: (i) 73.8-81 Gy at 1.8-2.0 Gy/fraction for EBRT alone (eviQ guidelines); (ii) 40-50 Gy (EBRT) for EBRT plus high-dose rate (HDR) brachytherapy boost (National Comprehensive Cancer Network (NCCN) guidelines); and (iii) 145 Gy for low dose rate (LDR) I-125 monotherapy (NCCN). Additionally, EBRT beam energy should be ≥6 MV using three-dimensional conformal RT (3D-CRT) or intensity-modulated RT (IMRT), and high-risk patients should receive neo-adjuvant androgen-deprivation therapy (ADT) (eviQ/NCCN). Treatment of pelvic nodes was also assessed. One hundred four high-risk, 84 intermediate-risk and 27 low-risk patients (NCCN criteria) were managed by eight of nine radiation oncologists. Concordance with guideline doses was confirmed in: (i) 125 of 136 patients (92%) treated with EBRT alone; (ii) 32 of 34 patients (94%) treated with EBRT + HDR BRT boost; and (iii) 45 of 45 patients (100%) treated with LDR BRT alone. All EBRT patients were treated with ≥6 MV beams using 3D-CRT (78%) or IMRT (22%). 84%, 21% and 0% of high-risk, intermediate-risk and low-risk patients received ADT, respectively. Overall treatment modality choice (including ADT use and duration where assessable) was concordant with guidelines for 176/207 (85%) of patients. The vast majority of patients were treated concordant with evidence-based guidelines suggesting that

  3. Health-Related Quality of Life in Patients With Locally Advanced Prostate Cancer After 76 Gy Intensity-Modulated Radiotherapy vs. 70 Gy Conformal Radiotherapy in a Prospective and Longitudinal Study

    International Nuclear Information System (INIS)

    Lips, Irene; Dehnad, Human; Kruger, Arto Boeken; Moorselaar, Jeroen van; Heide, Uulke van; Battermann, Jan; Vulpen, Marco van

    2007-01-01

    Purpose: To compare quality of life (QoL) after 70 Gy conformal radiotherapy with QoL after 76 Gy intensity-modulated radiotherapy (IMRT) in patients with locally advanced prostate carcinoma. Methods and Materials: Seventy-eight patients with locally advanced prostate cancer were treated with 70 Gy three-field conformal radiotherapy, and 92 patients received 76 Gy IMRT with fiducial markers for position verification. Quality of life was measured by RAND-36, the European Organization for Research and Treatment of Cancer core questionnaire (EORTC QLQ-C30(+3)), and the prostate-specific EORTC QLQ-PR25, before radiotherapy (baseline) and 1 month and 6 months after treatment. Quality of life changes in time (baseline vs. 1 month and baseline vs. 6 months) of ≥10 points were considered clinically relevant. Results: Differences between the treatment groups for QoL changes over time occurred in several QoL domains. The 76-Gy group revealed no significant deterioration in QoL compared with the 70-Gy group. The IMRT 76-Gy group even demonstrated a significantly better change in QoL from baseline to 1 month in several domains. The conformal 70-Gy group revealed temporary deterioration in pain, role functioning, and urinary symptoms; for the IMRT 76-Gy group a better QoL in terms of change in health existed after 1 month, which persisted after 6 months. For both treatment groups temporary deterioration in physical role restriction occurred after 1 month, and an improvement in emotional role restriction occurred after 6 months. Sexual activity was reduced after treatment for both groups and remained decreased after 6 months. Conclusions: Intensity-modulated radiotherapy and accurate position verification seem to provide a possibility to increase the radiation dose for prostate cancer without deterioration in QoL

  4. Beam shaping for conformal fractionated stereotactic radiotherapy: a modeling study

    International Nuclear Information System (INIS)

    Hacker, Fred L.; Kooy, Hanne M.; Bellerive, Marc R.; Killoran, Joseph H.; Leber, Zachary H.; Shrieve, Dennis C.; Tarbell, Nancy J.; Loeffler, Jay S.

    1997-01-01

    Purpose: The patient population treated with fractionated stereotactic radiotherapy (SRT) is significantly different than that treated with stereotactic radiosurgery (SRS). Generally, lesions treated with SRT are larger, less spherical, and located within critical regions of the central nervous system; hence, they offer new challenges to the treatment planner. Here a simple, cost effective, beam shaping system has been evaluated relative to both circular collimators and an ideal dynamically conforming system for effectiveness in providing conformal therapy for these lesions. Methods and Materials: We have modeled a simple system for conformal arc therapy using four independent jaws. The jaw positions and collimator angle are changed between arcs but held fixed for the duration of each arc. Eleven previously treated SRT cases have been replanned using this system. The rectangular jaw plans were then compared to the original treatment plans which used circular collimators. The plans were evaluated with respect to tissue sparing at 100%, 80%, 50%, and 20% of the prescription dose. A plan was also done for each tumor in which the beam aperture was continuously conformed to the beams eye view projection of the tumor. This was used as an ideal standard for conformal therapy in the absence of fluence modulation. Results: For tumors with a maximum extent of over 3.5 cm the rectangular jaw plans reduced the mean volume of healthy tissue involved at the prescription dose by 57% relative to the circular collimator plans. The ideal conformal plans offered no significant further improvement at the prescription dose. The relative advantage of the rectangular jaw plans decreased at lower isodoses so that at 20% of the prescription dose tissue involvement for the rectangular jaw plans was equivalent to that for the circular collimator plans. At these isodoses the ideal conformal plans gave substantially better tissue sparing. Conclusion: A simple and economical field shaping

  5. Computer controlled multi-leaf conformation radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, T [Tokyo Metropolitan Komagome Hospital (Japan); Inamura, K

    1981-10-01

    A conformation radiotherapy system with 5-split collimators of which openings can be controlled symmetrically by computerized techniques during rotational irradiation by a linear accelerator has been developed. Outline of the system performance and its clinical applications are described as follows. 1. Profile of the system: The hardware is composed of three parts, namely, the multi-split collimator, the electronic data processor, and the interface between those two parts. 1) The multi-leaf collimator is composed of 5 pairs (10 leaves) diaphragms. It can be mounted to the X-ray head of a linear accelerator when used, and can be dismounted after its use. 2) The electronic data processor sends control signal to the collimator according to the 5-leaf target volume data which can be stored into a minifloppy disc through the curve digitizer previously. This part is composed of a) dedicated micro processor, b) I/O expansion unit, c) color CRT display with key board, d) dual mini-floppy disc unit, e) curve digitizer and f) digital plotter for recording and verification of resulted accuracy. 2. Performance of the system: 1) Maximum field size: 15 cm x 15 cm at isocenter. 2) Maximum elongation ratio of the target volume: 3 : 1 when the longer diameter is 15 cm. 3) Control accuracy: Within +-3 mm deviation from planned beam focus at isocenter. 3. Clinical application: The method of treatment planning and clinical advantages of this irradiation method are explained by raising clinical experiences such as treating brain tumor and rectal cancer.

  6. Computer controlled multi-leaf conformation radiotherapy

    International Nuclear Information System (INIS)

    Matsuda, Tadayoshi; Inamura, Kiyonari.

    1981-01-01

    A conformation radiotherapy system with 5-split collimators of which openings can be controlled symmetrically by computerized techniques during rotational irradiation by a linear accelerator has been developed. Outline of the system performance and its clinical applications are described as follows. 1. Profile of the system: The hardware is composed of three parts, namely, the multi-split collimator, the electronic data processor, and the interface between those two parts. 1) The multi-leaf collimator is composed of 5 pairs (10 leaves) diaphragms. It can be mounted to the X-ray head of a linear accelerator when used, and can be dismounted after its use. 2) The electronic data processor sends control signal to the collimator according to the 5-leaf target volume data which can be stored into a minifloppy disc through the curve digitizer previously. This part is composed of a) dedicated micro processor, b) I/O expansion unit, c) color CRT display with key board, d) dual mini-floppy disc unit, e) curve digitizer and f) digital plotter for recording and verification of resulted accuracy. 2. Performance of the system: 1) Maximum field size: 15 cm x 15 cm at isocenter. 2) Maximum elongation ratio of the target volume: 3 : 1 when the longer diameter is 15 cm. 3) Control accuracy: Within +-3 mm deviation from planned beam focus at isocenter. 3. Clinical application: The method of treatment planning and clinical advantages of this irradiation method are explained by raising clinical experiences such as treating brain tumor and rectal cancer. (author)

  7. Implementation of intensity-modulated conformational radiotherapy for cervical cancers at the Alexis Vautrin Centre

    International Nuclear Information System (INIS)

    Renard-Oldrini, Sophie

    2010-01-01

    As platinum salt based concomitant conformational radiotherapy and chemotherapy have been used as a standard treatment for cervical cancers but resulted in digestive and haematological toxicities, this research thesis reports the application of intensity-modulated conformational radiation therapy. After having recalled some epidemiological, anatomical aspects, diagnosis and treatments aspects regarding cervical cancer, the author presents this last treatment technique (principles, benefits, practical implementation). The author discusses results obtained by an experiment during which seven patients have been treated by simple conformational radiation therapy, and four by intensity-modulated conformational radiation therapy. Results are discussed in terms of volumes (clinical target volume, growth target volume, planned target volume), dosimetric results, toxicities (urine and skin), weight loss [fr

  8. Toxicity and cosmetic outcome of three-dimensional conformal radiotherapy for accelerated partial breast irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gatti, M.; Bresciani, S.; Ponzone, R.; Panaia, R.; Salatino, A.; Stasi, M.; Gabriele, P. [IRCC, Candiolo (Italy)

    2011-10-15

    Full text of publication follows: Purpose.- To analyse the incidence and severity of acute and late normal tissue toxicity and cosmetic outcome using three - dimensional conformal radiotherapy to deliver accelerated partial breast irradiation. Patients and Methods.- 70 patients with stage I disease were treated with three-dimensional conformal radiotherapy for accelerated partial breast irradiation, in an approved protocol. The prescribed dose was 34 Gy in all patients delivered in 10 fractions over 5 consecutive days. On all CT scans gross tumor volume (GTV ) was defined around surgical clips. A 1.5 cm margin was added in order to account for clinical target volume (CTV) . A margin of 1 cm was added to CTI to define the planning target volume (PTV). The dose-volume constraints were followed in accordance with the specifications as dictated in the NSABP/RTOG protocol. After treatment, patients underwent a clinical and cosmetic evaluation every 3 months. Late toxicity was evaluated according to the RTOG grading schema. The cosmetic assessment was performed by the physicians using the controlateral untreated breast as the reference (Harvard scale). Results.- Median patient age was 66 years (range 51-80). Median follow-up was 15 months (range 6-46). Tumor size was < 10 mm in 33 patients (53%) and > 2 cm in 4(6%). The mean value of the ratio between the PTV and the whole ipsilateral breast volume was 38 % and the median percentage whole breast volume that received 95 % of prescribed dose was 34% (range 16%-55%). The rate of G1 and G2 acute skin toxicity was 28% and 2% respectively and the late toxicity was 17% (G1). G2 or greater toxicities were not observed. The most pronounced G1 late toxicity was subcutaneous fibrosis, developed in 3 patients. The cosmetic outcome was excellent in 83% and good in 17%. Conclusion.- Accelerated partial breast irradiation using three-dimensional conformal radiotherapy is technically feasible with very low acute and late toxicity. Long

  9. Implementation of an assurance system guarantee quality in the hospital radiotherapy department of Lenin Holguin, Cuba

    International Nuclear Information System (INIS)

    Gonzalez Lopez, Nadia; Perez Velasquez, Reytel; Sol Zamora

    2009-01-01

    By the need to develop a simple and effective method of reducing radiation accidents in the present work has as objective the implementation through a manual system assurance quality assurance department of radiotherapy based on ISO 9000 and 14000 , besides the IAEA TECDOC-1151. The Quality Manual is divided into four sessions: general, procedures for the realization of security testing, mechanical and dosimetric the Co-60 machine, procedures for the planning of treatments in gynecology locations, SNC, rectum and breast cancer and those relating to the search and / or simulation of the first patient treatment, all discussed and approved by the Quality Assurance Committee. We conclude that this document is essential in obtaining an increasing quality in conventional radiation treatments, plus must be a reference material in the training of technologists, doctors and medical physicist and the documentary basis for the conformation of the warranty program quality of radiation therapy 3D-CRT. (author)

  10. Use of benchmark dose-volume histograms for selection of the optimal technique between three-dimensional conformal radiation therapy and intensity-modulated radiation therapy in prostate cancer

    International Nuclear Information System (INIS)

    Luo Chunhui; Yang, Claus Chunli; Narayan, Samir; Stern, Robin L.; Perks, Julian; Goldberg, Zelanna; Ryu, Janice; Purdy, James A.; Vijayakumar, Srinivasan

    2006-01-01

    Purpose: The aim of this study was to develop and validate our own benchmark dose-volume histograms (DVHs) of bladder and rectum for both conventional three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), and to evaluate quantitatively the benefits of using IMRT vs. 3D-CRT in treating localized prostate cancer. Methods and Materials: During the implementation of IMRT for prostate cancer, our policy was to plan each patient with both 3D-CRT and IMRT. This study included 31 patients with T1b to T2c localized prostate cancer, for whom we completed double-planning using both 3D-CRT and IMRT techniques. The target volumes included prostate, either with or without proximal seminal vesicles. Bladder and rectum DVH data were summarized to obtain an average DVH for each technique and then compared using two-tailed paired t test analysis. Results: For 3D-CRT our bladder doses were as follows: mean 28.8 Gy, v60 16.4%, v70 10.9%; rectal doses were: mean 39.3 Gy, v60 21.8%, v70 13.6%. IMRT plans resulted in similar mean dose values: bladder 26.4 Gy, rectum 34.9 Gy, but lower values of v70 for the bladder (7.8%) and rectum (9.3%). These benchmark DVHs have resulted in a critical evaluation of our 3D-CRT techniques over time. Conclusion: Our institution has developed benchmark DVHs for bladder and rectum based on our clinical experience with 3D-CRT and IMRT. We use these standards as well as differences in individual cases to make decisions on whether patients may benefit from IMRT treatment rather than 3D-CRT

  11. Comparison of dosimetry distribution between three-dimension conformal and intensity modulated plan integrated with breath motion in postoperative radiation of gastric cancer

    International Nuclear Information System (INIS)

    Sun Wenjie; Zhang Zhen; Hu Weigang; Gu Weilie; Zhu Ji; Li Guichao; Cai Gang; Ma Xuejun

    2010-01-01

    Objective: To compare the dose distribution of the target and normal tissues in gastric cancers between three-dimension conformal radiation therapy (3DCRT) and intensity modulated radiation therapy (IMRT) plan when respiratory motion factors integrated in the plan. Methods: From January 2005 to November 2006, 10 patients with post-operatively radiation of gastric cancer were enrolled in this study. Planning CT were acquired conventionally with free-breath mode and the static treatment plans of the 3DCRT and IMRT were designed respectively. Probability distribution functions (PDF) were generated and convoluted with the static dose distributions from 3DCRT and IMRT plans to obtain the integrated plans. The dose distributions of the target and normal tissues were compared between 3DCRT and IMRT integration treatment plans, such as V 45 of clinical target volume, V 40 of liver and V 15 , V 18 of left and right kidney. Results: In the respiratory integrated treatment planning, the target volume coverage and homogeneity with IMRT are superior to those with 3DCRT ((V 45 98% : 87% (t = -3.35, P =0.010), mean dose 46.81 Gy ±0.75 Gy : 45.99 Gy ± 1.12 Gy (t = -0.31, P=0.020)). The V 40 of the liver in IMRT are smaller than those in 3DCRT ( 12% : 16%; t=3.75, P=0.010). For the left kidney, the V 15 and V 18 in IMRT are smaller than those in 3DCRT ((34% : 50% (t = 2.17, P = 0.050) and 27% : 46% (t = 3.11, P = 0.020) ),but for the right kidney, V 15 and V 18 in 3DCRT are smaller than those in IMRT ((15% : 21% (t = - 2.42, P=0.040) and 11% : 15% (t= -2.71, P=0.030)). Conclusions: When respiratory motion factor integrated in the treatment plan, IMRT showed advantage both in target coverage and normal tissue sparing in the high dose region of liver and left kidney. (authors)

  12. Applicator-guided volumetric-modulated arc therapy for low-risk endometrial cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cilla, Savino, E-mail: savinocilla@gmail.com [Medical Physics Unit, Fondazione di ricerca e cura “Giovanni Paolo II,” Università Cattolica del Sacro Cuore, Campobasso (Italy); Macchia, Gabriella [Radiation Oncology Unit, Fondazione di ricerca e cura “Giovanni Paolo II,” Università Cattolica del Sacro Cuore, Campobasso (Italy); Sabatino, Domenico [Medical Physics Unit, Fondazione di ricerca e cura “Giovanni Paolo II,” Università Cattolica del Sacro Cuore, Campobasso (Italy); Digesù, Cinzia; Deodato, Francesco [Radiation Oncology Unit, Fondazione di ricerca e cura “Giovanni Paolo II,” Università Cattolica del Sacro Cuore, Campobasso (Italy); Piermattei, Angelo [Physics Institute, Università Cattolica del Sacro Cuore, Rome (Italy); De Spirito, Marco [Medical Physics Unit, Fondazione di ricerca e cura “Giovanni Paolo II,” Università Cattolica del Sacro Cuore, Campobasso (Italy); Morganti, Alessio G. [Radiation Oncology Unit, Fondazione di ricerca e cura “Giovanni Paolo II,” Università Cattolica del Sacro Cuore, Campobasso (Italy); Radiation Oncology Unit, Università Cattolica del Sacro Cuore, Rome (Italy)

    2013-04-01

    The aim of this study was to report the feasibility of volumetric-modulated arc therapy (VMAT) in the postoperative irradiation of the vaginal vault. Moreover, the VMAT technique was compared with 3D conformal radiotherapy (3D-CRT) and fixed-field intensity-modulated radiotherapy (IMRT), in terms of target coverage and organs at risk sparing. The number of monitor units and the delivery time were analyzed to score the treatment efficiency. All plans were verified in a dedicated solid water phantom using a 2D array of ionization chambers. Twelve patients with endometrial carcinoma who underwent radical hystero-adenexectomy and fixed-field IMRT treatments were retrospectively included in this analysis; for each patient, plans were compared in terms of dose-volume histograms, homogeneity index, and conformity indexes. All techniques met the prescription goal for planning target volume coverage, with VMAT showing the highest level of conformity at all dose levels. VMAT resulted in significant reduction of rectal and bladder volumes irradiated at all dose levels compared with 3D-CRT. No significant differences were found with respect to IMRT. Moreover, a significant improvement of the dose conformity was reached by VMAT technique not only at the 95% dose level (0.74 vs. 0.67 and 0.62) but also at 50% and 75% levels of dose prescription. In addition, VMAT plans showed a significant reduction of monitor units by nearly 28% with respect to IMRT, and reduced treatment time from 11 to <3 minutes for a single 6-Gy fraction. In conclusion, VMAT plans can be planned and carried out with high quality and efficiency for the irradiation of vaginal vault alone, providing similar or better sparing of organs at risk to fixed-field IMRT and resulting in the most efficient treatment option. VMAT is currently our standard approach for radiotherapy of low-risk endometrial cancer.

  13. Dosimetric comparison of the related parameters between simultaneous integrated boost intensity-modulated radiotherapy and sequential boost conformal radiotherapy for postoperative malignant glioma of the brain

    International Nuclear Information System (INIS)

    Shao Qian; Lu Jie; Li Jianbin; Sun Tao; Bai Tong; Liu Tonghai; Yin Yong

    2011-01-01

    Objective: To compare the dosimetric of different parameter of simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) with sequential boost conformal radiotherapy (SB-CRT) for postoperative malignant glioma of the brain. Methods: Ten patients with malignant glioma of brain were selected to study. Each patient was simulated all by CT and MRI, and the imagings of CT and MRI were all sent to Pinnacle 3 planning system. The fusion technology with MR-CT imaging was used on Pinnacle 3 planning system. The target volume was delineated and defined based on MRI. The postoperative residual lesion and resection cavity were defined as gross tumor volume (GTV) and expanded GTV some scope was defined as clinical target volume (CTV). The margins of GTV expanded 10 mm and 25 mm were defined as CTV1 and CTV2 respectively. CTV1 and CTV2 all enlarged 5 mm were defined as PTV1 and PTV2 respectively. The plans of simultaneous integrated boost intensity-modulated radiotherapy and sequential boost conformal radiotherapy were respectively designed for each patient using Pinnacle 3 planning system and the dosimetric of different parameter was compared. The prescribe dose of SIB-IMRT was PTV1: 62.5 Gy/25 f, PTV2: 50.0 Gy/25 f; and SB-CRT was PTV1: 66.0 Gy/33 f, PTV2: 50.0 Gy/25 f. The dosimetries of different parameters of SIB-IMRT and SB-CRT were compared by using Paired-Samples T Test. Results: The maximum and mean dose of PTV1, PTV2, and brainstem were of significant difference (P 0.05). Conclusion: The SIB-IMRT plan is better than the SB-CRT plan. The CI and HI of SIB-IMRT are superior to SB-CRT. At the same time, it can preserve the important organs such as brainstem and reduce the mean dose of whole brain. On the other hand it can shorten the total period of therapy time. (authors)

  14. A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapy

    International Nuclear Information System (INIS)

    Nutting, Christopher M.; Bedford, James L.; Cosgrove, Vivian P.; Tait, Diana M.; Dearnaley, David P.; Webb, Steve

    2001-01-01

    Background and purpose: To investigate the potential of intensity-modulated radiotherapy (IMRT) to reduce lung irradiation in the treatment of oesophageal carcinoma with radical radiotherapy. Materials and methods: A treatment planning study was performed to compare two-phase conformal radiotherapy (CFRT) with IMRT in five patients. The CFRT plans consisted of anterior, posterior and bilateral posterior oblique fields, while the IMRT plans consisted of either nine equispaced fields (9F), or four fields (4F) with orientations equal to the CFRT plans. IMRT plans with seven, five or three equispaced fields were also investigated in one patient. Treatment plans were compared using dose-volume histograms and normal tissue complication probabilities. Results: The 9F IMRT plan was unable to improve on the homogeneity of dose to the planning target volume (PTV), compared with the CFRT plan (dose range, 16.9±4.5 (1 SD) vs. 12.4±3.9%; P=0.06). Similarly, the 9F IMRT plan was unable to reduce the mean lung dose (11.7±3.2 vs. 11.0±2.9 Gy; P=0.2). Similar results were obtained for seven, five and three equispaced fields in the single patient studied. The 4F IMRT plan provided comparable PTV dose homogeneity with the CFRT plan (11.8±3.3 vs. 12.4±3.9%; P=0.6), with reduced mean lung dose (9.5±2.3 vs 11.0±2.9 Gy; P=0.001). Conclusions: IMRT using nine equispaced fields provided no improvement over CFRT. This was because the larger number of fields in the IMRT plan distributed a low dose over the entire lung. In contrast, IMRT using four fields equal to the CFRT fields offered an improvement in lung sparing. Thus, IMRT with a few carefully chosen field directions may lead to a modest reduction in pneumonitis, or allow tumour dose escalation within the currently accepted lung toxicity

  15. A system for remote dosimetry audit of 3D-CRT, IMRT and VMAT based on lithium formate dosimetry

    International Nuclear Information System (INIS)

    Adolfsson, Emelie; Gustafsson, Håkan; Lund, Eva; Alm Carlsson, Gudrun; Olsson, Sara; Carlsson Tedgren, Åsa

    2014-01-01

    Summary: The aim of this work was to develop and test a remote end-to-end audit system using lithium formate EPR dosimeters. Four clinics were included in a pilot study, absorbed doses determined in the PTV agreed with TPS calculated doses within ±5% for 3D-CRT and ±7% (k = 1) for IMRT/VMAT dose plans

  16. Dosimetric comparison of intensity-modulated, conformal, and four-field pelvic radiotherapy boost plans for gynecologic cancer: a retrospective planning study

    International Nuclear Information System (INIS)

    Chan, Philip; Yeo, Inhwan; Perkins, Gregory; Fyles, Anthony; Milosevic, Michael

    2006-01-01

    To evaluate intensity-modulated radiation therapy (IMRT) as an alternative to conformal radiotherapy (CRT) or 4-field box boost (4FB) in women with gynecologic malignancies who are unsuitable for brachytherapy for technical or medical reasons. Dosimetric and toxicity information was analyzed for 12 patients with cervical (8), endometrial (2) or vaginal (2) cancer previously treated with external beam pelvic radiotherapy and a CRT boost. Optimized IMRT boost treatment plans were then developed for each of the 12 patients and compared to CRT and 4FB plans. The plans were compared in terms of dose conformality and critical normal tissue avoidance. The median planning target volume (PTV) was 151 cm 3 (range 58–512 cm 3 ). The median overlap of the contoured rectum with the PTV was 15 (1–56) %, and 11 (4–35) % for the bladder. Two of the 12 patients, both with large PTVs and large overlap of the contoured rectum and PTV, developed grade 3 rectal bleeding. The dose conformity was significantly improved with IMRT over CRT and 4FB (p ≤ 0.001 for both). IMRT also yielded an overall improvement in the rectal and bladder dose-volume distributions relative to CRT and 4FB. The volume of rectum that received the highest doses (>66% of the prescription) was reduced by 22% (p < 0.001) with IMRT relative to 4FB, and the bladder volume was reduced by 19% (p < 0.001). This was at the expense of an increase in the volume of these organs receiving doses in the lowest range (<33%). These results indicate that IMRT can improve target coverage and reduce dose to critical structures in gynecologic patients receiving an external beam radiotherapy boost. This dosimetric advantage will be integrated with other patient and treatment-specific factors, particularly internal tumor movement during fractionated radiotherapy, in the context of a future image-guided radiation therapy study

  17. Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Hamilton, Russell J.; Kuchnir, Franca T.; Sweeney, Patrick; Rubin, Steven J.; Dujovny, Manuel; Pelizzari, Charles A.; Chen, George T. Y.

    1995-01-01

    Purpose: Compare the use of static conformal fields with the use of multiple noncoplanar arcs for stereotactic radiosurgery or stereotactic radiotherapy treatment of intracranial lesions. Evaluate the efficacy of these treatment techniques to deliver dose distributions comparable to those considered acceptable in current radiotherapy practice. Methods and Materials: A previously treated radiosurgery case of a patient presenting with an irregularly shaped intracranial lesion was selected. Using a three-dimensional (3D) treatment-planning system, treatment plans using a single isocenter multiple noncoplanar arc technique and multiple noncoplanar conformal static fields were generated. Isodose distributions and dose volume histograms (DVHs) were computed for each treatment plan. We required that the 80% (of maximum dose) isodose surface enclose the target volume for all treatment plans. The prescription isodose was set equal to the minimum target isodose. The DVHs were analyzed to evaluate and compare the different treatment plans. Results: The dose distribution in the target volume becomes more uniform as the number of conformal fields increases. The volume of normal tissue receiving low doses (> 10% of prescription isodose) increases as the number of static fields increases. The single isocenter multiple arc plan treats the greatest volume of normal tissue to low doses, approximately 1.6 times more volume than that treated by four static fields. The volume of normal tissue receiving high (> 90% of prescription isodose) and intermediate (> 50% of prescription isodose) doses decreases by 29 and 22%, respectively, as the number of static fields is increased from four to eight. Increasing the number of static fields to 12 only further reduces the high and intermediate dose volumes by 10 and 6%, respectively. The volume receiving the prescription dose is more than 3.5 times larger than the target volume for all treatment plans. Conclusions: Use of a multiple noncoplanar

  18. Localized field conformation radiotherapy combined with endocrine therapy for the treatment of prostate cancer

    International Nuclear Information System (INIS)

    Karasawa, Katsuyuki; Kaizu, Toshihide; Kurosaki, Hiromasa; Tanaka, Yoshiaki

    1999-01-01

    To improve the quality of life (QOL) of the patients with prostate cancer, we limit the radiotherapy target volume to the prostate and seminal vesicles while using endocrine therapy towards the disease outside the target volume. Radiotherapy technique was rotation conformation technique with computer-controlled multileaf collimators to the total doses of up to 66-70 Gy. Among 145 evaluable cases with the median age of 74, overall and cause-specific 5-year survival rates were 59.3% and 84.1%, respectively, and the relative survival rate of the Stage A-C cases was 100%. The two thirds (33/50) of the deaths were not of prostate cancer. The rate of severe complication was 1.4%. As for QOL, the rate of impotence was 90%, however, the patients' overall satisfaction towards the treatment was 90%. From this analysis, this combined treatment seems beneficial in the treatment of prostate cancer. (author)

  19. Individualized margins in 3D conformal radiotherapy planning for lung cancer: analysis of physiological movements and their dosimetric impacts.

    Science.gov (United States)

    Germain, François; Beaulieu, Luc; Fortin, André

    2008-01-01

    In conformal radiotherapy planning for lung cancer, respiratory movements are not taken into account when a single computed tomography (CT) scan is performed. This study examines tumor movements to design individualized margins to account for these movements and evaluates their dosimetric impacts on planning volume. Fifteen patients undergoing CT-based planning for radical radiotherapy for localized lung cancer formed the study cohort. A reference plan was constructed based on reference gross, clinical, and planning target volumes (rGTV, rCTV, and rPTV, respectively). The reference plans were compared with individualized plans using individualized margins obtained by using 5 serial CT scans to generate individualized target volumes (iGTV, iCTV, and iPTV). Three-dimensional conformal radiation therapy was used for plan generation using 6- and 23-MV photon beams. Ten plans for each patient were generated and dose-volume histograms (DVHs) were calculated. Comparisons of volumetric and dosimetric parameters were performed using paired Student t-tests. Relative to the rGTV, the total volume occupied by the superimposed GTVs increased progressively with each additional CT scans. With the use of all 5 scans, the average increase in GTV was 52.1%. For the plans with closest dosimetric coverage, target volume was smaller (iPTV/rPTV ratio 0.808) but lung irradiation was only slightly decreased. Reduction in the proportion of lung tissue that received 20 Gy or more outside the PTV (V20) was observed both for 6-MV plans (-0.73%) and 23-MV plans (-0.65%), with p = 0.02 and p = 0.04, respectively. In conformal RT planning for the treatment of lung cancer, the use of serial CT scans to evaluate respiratory motion and to generate individualized margins to account for these motions produced only a limited lung sparing advantage.

  20. Individualized Margins in 3D Conformal Radiotherapy Planning for Lung Cancer: Analysis of Physiological Movements and Their Dosimetric Impacts

    International Nuclear Information System (INIS)

    Germain, Francois; Beaulieu, Luc; Fortin, Andre

    2008-01-01

    In conformal radiotherapy planning for lung cancer, respiratory movements are not taken into account when a single computed tomography (CT) scan is performed. This study examines tumor movements to design individualized margins to account for these movements and evaluates their dosimetric impacts on planning volume. Fifteen patients undergoing CT-based planning for radical radiotherapy for localized lung cancer formed the study cohort. A reference plan was constructed based on reference gross, clinical, and planning target volumes (rGTV, rCTV, and rPTV, respectively). The reference plans were compared with individualized plans using individualized margins obtained by using 5 serial CT scans to generate individualized target volumes (iGTV, iCTV, and iPTV). Three-dimensional conformal radiation therapy was used for plan generation using 6- and 23-MV photon beams. Ten plans for each patient were generated and dose-volume histograms (DVHs) were calculated. Comparisons of volumetric and dosimetric parameters were performed using paired Student t-tests. Relative to the rGTV, the total volume occupied by the superimposed GTVs increased progressively with each additional CT scans. With the use of all 5 scans, the average increase in GTV was 52.1%. For the plans with closest dosimetric coverage, target volume was smaller (iPTV/rPTV ratio 0.808) but lung irradiation was only slightly decreased. Reduction in the proportion of lung tissue that received 20 Gy or more outside the PTV (V20) was observed both for 6-MV plans (-0.73%) and 23-MV plans (-0.65%), with p = 0.02 and p = 0.04, respectively. In conformal RT planning for the treatment of lung cancer, the use of serial CT scans to evaluate respiratory motion and to generate individualized margins to account for these motions produced only a limited lung sparing advantage

  1. SU-F-J-221: Adjusted Dose and Its Relation to Radiation Induced Liver Disease During Hepatocellular Carcinoma Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Huang, P; Gang, Y; Qin, S; Li, D [Shandong Province Key Laboratory of Medical Physics and Image Processing Technology, School of Physics and Electronics, Shandong Normal University (China); Li, H; Chen, J; Ma, C; Yin, Y [Department of Radiation Oncology, Shandong Cancer Hospital and Institute (China)

    2016-06-15

    Purpose: Many patients with hepatocellular carcinoma (HCC) had hepatic anatomy variations as a result of inter-fraction deformation during fractionated radiotherapy, which may result in difference from the planned dose. This study aimed to investigate the relationship between adjusted dose and radiation induced liver disease (RILD) in HCC patients receiving three dimensional conformal radiotherapy (3DCRT). Methods: Twenty-three HCC patients received conventional fractionated 3DCRT were enrolled in this retrospective investigation. Among them, seven patients had been diagnosed of RILD post-radiotherapy, including 4 cases of grade 2, 3 cases of grade 3 according to the CTCAE Version 3.0. Daily cone-beam CT (CBCT) scans were acquired throughout the whole treatment course for each patient. To reconstruct the daily dose to a patient considering the interfraction anatomy variations, the planned beams from each patient’s treatment plan were firstly applied to each daily modified CBCT (mCBCT). The daily doses were then summed together with the help of deformable image registration (DIR) to obtain the adjusted dose (Dadjusted) of the patient. Finally, the dose changes in normal liver between planned dose (Dplan) and Dadjusted were evaluated by V20, V30, V40 and the mean dose to normal liver (MDTNL). Univariate analysis was performed to identify the significant dose changes. Results: Among the twenty-three patients, the adjusted liver V20, V30, V40 and MDTNL showed significant changes from the planned ones (p<0.05) and averagely increased by 4.1%, 4.7%, 4.5% and 3.9Gy, respectively. And the adjusted liver dose in twenty-one patients (91%) were higher than planned value, the adjusted dose of patients with RILD (6/7) exceeds to the hepatic radiation tolerance. Conclusion: The adjusted dose of all the studied patients significantly differs from planned dose, and mCBCT-based dose reconstruction can aid in evaluating the robustness of the planning solutions, and adjusted dose

  2. Minimising contralateral breast dose in post-mastectomy intensity-modulated radiotherapy by incorporating conformal electron irradiation

    NARCIS (Netherlands)

    van der Laan, Hans Paul; Korevaar, Erik W; Dolsma, Willemtje; Maduro, John H; Langendijk, Johannes A

    PURPOSE: To assess the potential benefit of incorporating conformal electron irradiation in intensity-modulated radiotherapy (IMRT) for loco-regional post-mastectomy RT. PATIENTS AND METHODS: Ten consecutive patients that underwent left-sided mastectomy were selected for this comparative planning

  3. Evaluation of Sentinel Lymph Node Dose Distribution in 3D Conformal Radiotherapy Techniques in 67 pN0 Breast Cancer Patients.

    Science.gov (United States)

    Witucki, Gerlo; Degregorio, Nikolaus; Rempen, Andreas; Schwentner, Lukas; Bottke, Dirk; Janni, Wolfgang; Ebner, Florian

    2015-01-01

    Introduction. The anatomic position of the sentinel lymph node is variable. The purpose of the following study was to assess the dose distribution delivered to the surgically marked sentinel lymph node site by 3D conformal radio therapy technique. Material and Method. We retrospectively analysed 70 radiotherapy (RT) treatment plans of consecutive primary breast cancer patients with a successful, disease-free, sentinel lymph node resection. Results. In our case series the SN clip volume received a mean dose of 40.7 Gy (min 28.8 Gy/max 47.6 Gy). Conclusion. By using surgical clip markers in combination with 3D CT images our data supports the pathway of tumouricidal doses in the SN bed. The target volume should be defined by surgical clip markers and 3D CT images to give accurate dose estimations.

  4. Impact of intensity-modulated radiation therapy as a boost treatment on the lung-dose distributions for non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Choi, Youngmin; Kim, Jeung Kee; Lee, Hyung Sik; Hur, Won Joo; Chai, Gyu Young; Kang, Ki Mun

    2005-01-01

    Purpose: To investigate the feasibility of intensity-modulated radiotherapy (IMRT) as a method of boost radiotherapy after the initial irradiation by the conventional anterior/posterior opposed beams for centrally located non-small-cell lung cancer through the evaluation of dose distributions according to the various boost methods. Methods and Materials: Seven patients with T3 or T4 lung cancer and mediastinal node enlargement who previously received radiotherapy were studied. All patients underwent virtual simulation retrospectively with the previous treatment planning computed tomograms. Initial radiotherapy plans were designed to deliver 40 Gy to the primary tumor and involved nodal regions with the conventional anterior/posterior opposed beams. Two radiation dose levels, 24 and 30 Gy, were used for the boost radiotherapy plans, and four different boost methods (a three-dimensional conformal radiotherapy [3DCRT], five-, seven-, and nine-beam IMRT) were applied to each dose level. The goals of the boost plans were to deliver the prescribed radiation dose to 95% of the planning target volume (PTV) and minimize the volumes of the normal lungs and spinal cord irradiated above their tolerance doses. Dose distributions in the PTVs and lungs, according to the four types of boost plans, were compared in the boost and sum plans, respectively. Results: The percentage of lung volumes irradiated >20 Gy (V20) was reduced significantly in the IMRT boost plans compared with the 3DCRT boost plans at the 24- and 30-Gy dose levels (p 0.007 and 0.0315 respectively). Mean lung doses according to the boost methods were not different in the 24- and 30-Gy boost plans. The conformity indexes (CI) of the IMRT boost plans were lower than those of the 3DCRT plans in the 24- and 30-Gy plans (p = 0.001 in both). For the sum plans, there was no difference of the dose distributions in the PTVs and lungs according to the boost methods. Conclusions: In the boost plans the V20s and CIs were

  5. Induction chemotherapy plus three-dimensional conformal radiation therapy in the definitive treatment of locally advanced non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Sim, Sang; Rosenzweig, Kenneth E.; Schindelheim, Rachel; Ng, Kenneth K.; Leibel, Steven A.

    2001-01-01

    Purpose: To evaluate our institution's experience using chemotherapy in conjunction with three-dimensional conformal radiation therapy (3D-CRT). Methods and Materials: From 1991 to 1998, 152 patients with Stage III non-small-cell lung cancer (NSCLC) were treated with 3D-CRT at Memorial Sloan-Kettering Cancer Center. A total of 137 patients (90%) were surgically staged with either thoracotomy or mediastinoscopy. The remainder were staged radiographically. Seventy patients were treated with radiation therapy alone, and 82 patients received induction chemotherapy before radiation. The majority of chemotherapy-treated patients received a platinum-containing regimen. Radiation was delivered with a 3D conformal technique using CT-based treatment planning. The median dose in the radiation alone group was 70.2 Gy, while in the combined modality group, it was 64.8 Gy. Results: The median follow-up time was 30.5 months among survivors. Stage IIIB disease was present in 36 patients (51%) in the radiation-alone group and 57 patients (70%) in the combined-modality group. Thirty-nine patients had poor prognostic factors (KPS 5%), and they were equally distributed between the two groups. The median survival times for the radiation-alone and the combined-modality groups were 11.7 months and 18.1 months, respectively (p=0.001). The 2-year rates of local control in the radiation-alone and combined-modality groups were 35.4% and 43.1%, respectively (p=0.1). Grade 3 or worse nonhematologic toxicity occurred in 20% of the patients receiving radiation alone and in 16% of those receiving chemotherapy and radiation. Overall, there were only 4 cases of Grade 3 or worse esophagitis. Conclusion: Despite more Stage IIIB patients in the combined-modality group, the addition of chemotherapy to 3D-CRT produced a survival advantage over 3D-CRT alone in Stage III NSCLC without a concomitant increase in toxicity. Chemotherapy thus appears to be beneficial, even in patients who are receiving higher

  6. Postoperative Intensity Modulated Radiation Therapy in High Risk Prostate Cancer: A Dosimetric Comparison

    International Nuclear Information System (INIS)

    Digesu, Cinzia; Cilla, Savino; De Gaetano, Andrea; Massaccesi, Mariangela; Macchia, Gabriella; Ippolito, Edy; Deodato, Francesco; Panunzi, Simona; Iapalucci, Chiara; Mattiucci, Gian Carlo; D'Angelo, Elisa; Padula, Gilbert D.A.; Valentini, Vincenzo; Cellini, Numa

    2011-01-01

    The aim of this study was to compare intensity-modulated radiation therapy (IMRT) with 3D conformal technique (3D-CRT), with respect to target coverage and irradiation of organs at risk for high dose postoperative radiotherapy (PORT) of the prostate fossa. 3D-CRT and IMRT treatment plans were compared with respect to dose to the rectum and bladder. The dosimetric comparison was carried out in 15 patients considering 2 different scenarios: (1) exclusive prostate fossa irradiation, and (2) pelvic node irradiation followed by a boost on the prostate fossa. In scenario (1), a 3D-CRT plan (box technique) and an IMRT plan were calculated and compared for each patient. In scenario (2), 3 treatment plans were calculated and compared for each patient: (a) 3D-CRT box technique for both pelvic (prophylactic nodal irradiation) and prostate fossa irradiation (3D-CRT only); (b) 3D-CRT box technique for pelvic irradiation followed by an IMRT boost to the prostatic fossa (hybrid 3D-CRT and IMRT); and (c) IMRT for both pelvic and prostate fossa irradiation (IMRT only). For exclusive prostate fossa irradiation, IMRT significantly reduced the dose to the rectum (lower Dmean, V50%, V75%, V90%, V100%, EUD, and NTCP) and the bladder (lower Dmean, V50%, V90%, EUD and NTCP). When prophylactic irradiation of the pelvis was also considered, plan C (IMRT only) performed better than plan B (hybrid 3D-CRT and IMRT) as respect to both rectum and bladder irradiation (reduction of Dmean, V50%, V75%, V90%, equivalent uniform dose [EUD], and normal tissue complication probability [NTCP]). Plan (b) (hybrid 3D-CRT and IMRT) performed better than plan (a) (3D-CRT only) with respect to dose to the rectum (lower Dmean, V75%, V90%, V100%, EUD, and NTCP) and the bladder (Dmean, EUD, and NTCP). Postoperative IMRT in prostate cancer significantly reduces rectum and bladder irradiation compared with 3D-CRT.

  7. Evaluation of organ-specific peripheral doses after 2-dimensional, 3-dimensional and hybrid intensity modulated radiation therapy for breast cancer based on Monte Carlo and convolution/superposition algorithms: Implications for secondary cancer risk assessment

    International Nuclear Information System (INIS)

    Joosten, Andreas; Matzinger, Oscar; Jeanneret-Sozzi, Wendy; Bochud, François; Moeckli, Raphaël

    2013-01-01

    Background and purpose: To make a comprehensive evaluation of organ-specific out-of-field doses using Monte Carlo (MC) simulations for different breast cancer irradiation techniques and to compare results with a commercial treatment planning system (TPS). Materials and methods: Three breast radiotherapy techniques using 6MV tangential photon beams were compared: (a) 2DRT (open rectangular fields), (b) 3DCRT (conformal wedged fields), and (c) hybrid IMRT (open conformal + modulated fields). Over 35 organs were contoured in a whole-body CT scan and organ-specific dose distributions were determined with MC and the TPS. Results: Large differences in out-of-field doses were observed between MC and TPS calculations, even for organs close to the target volume such as the heart, the lungs and the contralateral breast (up to 70% difference). MC simulations showed that a large fraction of the out-of-field dose comes from the out-of-field head scatter fluence (>40%) which is not adequately modeled by the TPS. Based on MC simulations, the 3DCRT technique using external wedges yielded significantly higher doses (up to a factor 4–5 in the pelvis) than the 2DRT and the hybrid IMRT techniques which yielded similar out-of-field doses. Conclusions: In sharp contrast to popular belief, the IMRT technique investigated here does not increase the out-of-field dose compared to conventional techniques and may offer the most optimal plan. The 3DCRT technique with external wedges yields the largest out-of-field doses. For accurate out-of-field dose assessment, a commercial TPS should not be used, even for organs near the target volume (contralateral breast, lungs, heart)

  8. Interobserver delineation uncertainty in involved-node radiation therapy (INRT) for early-stage Hodgkin lymphoma: on behalf of the Radiotherapy Committee of the EORTC lymphoma group.

    Science.gov (United States)

    Aznar, Marianne C; Girinsky, Theodore; Berthelsen, Anne Kiil; Aleman, Berthe; Beijert, Max; Hutchings, Martin; Lievens, Yolande; Meijnders, Paul; Meidahl Petersen, Peter; Schut, Deborah; Maraldo, Maja V; van der Maazen, Richard; Specht, Lena

    2017-04-01

    In early-stage classical Hodgkin lymphoma (HL) the target volume nowadays consists of the volume of the originally involved nodes. Delineation of this volume on a post-chemotherapy CT-scan is challenging. We report on the interobserver variability in target volume definition and its impact on resulting treatment plans. Two representative cases were selected (1: male, stage IB, localization: left axilla; 2: female, stage IIB, localizations: mediastinum and bilateral neck). Eight experienced observers individually defined the clinical target volume (CTV) using involved-node radiotherapy (INRT) as defined by the EORTC-GELA guidelines for the H10 trial. A consensus contour was generated and the standard deviation computed. We investigated the overlap between observer and consensus contour [Sørensen-Dice coefficient (DSC)] and the magnitude of gross deviations between the surfaces of the observer and consensus contour (Hausdorff distance). 3D-conformal (3D-CRT) and intensity-modulated radiotherapy (IMRT) plans were calculated for each contour in order to investigate the impact of interobserver variability on each treatment modality. Similar target coverage was enforced for all plans. The median CTV was 120 cm 3 (IQR: 95-173 cm 3 ) for Case 1, and 255 cm 3 (IQR: 183-293 cm 3 ) for Case 2. DSC values were generally high (>0.7), and Hausdorff distances were about 30 mm. The SDs between all observer contours, providing an estimate of the systematic error associated with delineation uncertainty, ranged from 1.9 to 3.8 mm (median: 3.2 mm). Variations in mean dose resulting from different observer contours were small and were not higher in IMRT plans than in 3D-CRT plans. We observed considerable differences in target volume delineation, but the systematic delineation uncertainty of around 3 mm is comparable to that reported in other tumour sites. This report is a first step towards calculating an evidence-based planning target volume margin for INRT in HL.

  9. Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer

    International Nuclear Information System (INIS)

    Ercan, T.; Alco, G.; Zengin, F.; Atilla, S.; Dincer, M.; Igdem, S.; Okkan, S.

    2010-01-01

    The aim of this study was to be able to implement the field-in-field intensity-modulated radiotherapy (FiF) technique in our daily practice for breast radiotherapy. To do this, we performed a dosimetric comparison. Treatment plans were produced for 20 consecutive patients. FiF plans and conformal radiotherapy (CRT) plans were compared for doses in the planning target volume (PTV), the dose homogeneity index (DHI), doses in irradiated soft tissue outside the target volume (SST), ipsilateral lung and heart doses for left breast irradiation, and the monitor unit counts (MU) required for treatment. Averaged values were compared using Student's t-test. With FiF, the DHI is improved 7.0% and 5.7%, respectively (P<0.0001) over the bilateral and lateral wedge CRT techniques. When the targeted volumes received 105% and 110% of the prescribed dose in the PTV were compared, significant decreases are found with the FiF technique. With the 105% dose, the SST, heart, and ipsilateral lung doses and the MU counts were also significantly lower with the FiF technique. The FiF technique, compared to CRT, for breast radiotherapy enables significantly better dose distribution in the PTV. Significant differences are also found for soft tissue volume, the ipsilateral lung dose, and the heart dose. Considering the decreased MUs needed for treatment, the FiF technique is preferred over tangential CRT. (author)

  10. Dosimetric comparison of volumetric modulated arc therapy (VMAT), DMlC (Dynamic IMRT), and 3DCRT in left breast cancer after breast conserving surgery receiving left breast irradiation

    International Nuclear Information System (INIS)

    Pratibha, Bauskar; Vibhay, Pareek; Rajendra, Bhalavat; Chandra, Manish

    2016-01-01

    Previous studies have demonstrated that the risk of ischemic heart disease is increased as a result of exposure to ionizing radiation in women treated for breast cancer. Alternative radiation techniques, such as dynamic intensity-modulated radiation therapy (DMLC), volumetric-modulated arc therapy (VMAT), have been shown to improve dosimetric parameters of the heart and substructures. However, these techniques have not been compared with each other to potentially guide treatment decisions. Volumetric modulated arc therapy (VMAT) is a novel extension of conventional intensity-modulated radiotherapy (c-IMRT), in which an optimized three dimensional dose distribution may be delivered in a single gantry rotation. VMAT is the predecessor to Rapid-Arc (Varian Medical System). This study uses VMAT, DMLC and 3DCRT to compare target volume coverage and doses to organs at risk (OARs), especially lung and heart doses, using these three techniques in whole breast irradiation after breast conserving surgery in left breast cancer cases

  11. Planning benchmark study for SBRT of early stage NSCLC. Results of the DEGRO Working Group Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Moustakis, Christos [University Muenster, Department of Radiation Oncology, Muenster (Germany); German CyberKnife Center, Soest (Germany); Blanck, Oliver [UKSH Universitaetsklinikum Schleswig Holstein, Department of Radiation Oncology, Kiel (Germany); Saphir Radiosurgery Center, Guestrow and Frankfurt, Frankfurt (Germany); Ebrahimi Tazehmahalleh, Fatemeh [University Muenster, Department of Radiation Oncology, Muenster (Germany); City Hospital Dessau, Dessau (Germany); Chan, Mark ka heng [UKSH Universitaetsklinikum Schleswig Holstein, Department of Radiation Oncology, Kiel (Germany); Ernst, Iris; Haverkamp, Uwe; Eich, Hans Theodor [University Muenster, Department of Radiation Oncology, Muenster (Germany); German CyberKnife Center, Soest (Germany); Krieger, Thomas [University of Wuerzburg, Department of Radiation Oncology, Wuerzburg (Germany); Duma, Marciana-Nona; Oechsner, Markus [Technical University of Munich, Department of Radiation Oncology, Klinikum rechts der Isar, Munich (Germany); Ganswindt, Ute; Heinz, Christian [Ludwig-Maximilians-University, Department of Radiation Oncology, Munich (Germany); Alheit, Horst; Blank, Hilbert [Radiationtherapy Distler, Bautzen (Germany); Nestle, Ursula; Wiehle, Rolf [University Medical Center Freiburg, Department of Radiation Oncology, Freiburg (Germany); Kornhuber, Christine; Ostheimer, Christian [University Halle, Department of Radiation Oncology, Halle (Germany); Petersen, Cordula [University Hospital Hamburg-Eppendorf, Hamburg (Germany); Pollul, Gerhard [University Mainz, Department of Radiation Oncology, Mainz (Germany); Baus, Wolfgang; Altenstein, Georg [University Hospital of Cologne, Cologne (Germany); Beckers, Eric; Jurianz, Katrin [Gamma Knife Center Krefeld, Krefeld (Germany); Sterzing, Florian [University Hospital Heidelberg, Heidelberg (Germany); Kretschmer, Matthias [Radiologische Allianz Hamburg, Hamburg (Germany); Seegenschmiedt, Heinrich; Maass, Torsten [Radiationtherapy and Cyberknife Center Hamburg, Hamburg (Germany); Droege, Stefan [Lung Clinic Hemer, Hemer (Germany); Wolf, Ulrich [University Leipzig, Department of Radiation Oncology, Leipzig (Germany); Schoeffler, Juergen [Radiationtherapy Department Boeblingen, Boeblingen (Germany); Guckenberger, Matthias [University Zurich, Department of Radiation Oncology, Zurich (Switzerland)

    2017-10-15

    The aim was to evaluate stereotactic body radiation therapy (SBRT) treatment planning variability for early stage nonsmall cell lung cancer (NSCLC) with respect to the published guidelines of the Stereotactic Radiotherapy Working Group of the German Society for Radiation Oncology (DEGRO). Planning computed tomography (CT) scan and the structure sets (planning target volume, PTV; organs at risk, OARs) of 3 patients with early stage NSCLC were sent to 22 radiotherapy departments with SBRT experience: each department was asked to prepare a treatment plan according to the DEGRO guidelines. The prescription dose was 3 fractions of 15 Gy to the 65% isodose. In all, 87 plans were generated: 36 used intensity-modulated arc therapy (IMAT), 21 used three-dimensional conformal radiation therapy (3DCRT), 6 used static field intensity-modulated radiation therapy (SF-IMRT), 9 used helical radiotherapy and 15 used robotic radiosurgery. PTV dose coverage and simultaneously kept OARs doses were within the clinical limits published in the DEGRO guidelines. However, mean PTV dose (mean 58.0 Gy, range 52.8-66.4 Gy) and dose conformity indices (mean 0.75, range 0.60-1.00) varied between institutions and techniques (p ≤ 0.02). OARs doses varied substantially between institutions, but appeared to be technique independent (p = 0.21). All studied treatment techniques are well suited for SBRT of early stage NSCLC according to the DEGRO guidelines. Homogenization of SBRT practice in Germany is possible through the guidelines; however, detailed treatment plan characteristics varied between techniques and institutions and further homogenization is warranted in future studies and recommendations. Optimized treatment planning should always follow the ALARA (as low as reasonably achievable) principle. (orig.) [German] Ziel war die Untersuchung der Variabilitaet der Bestrahlungsplanung der stereotaktischen Strahlentherapie (SBRT) fuer das nicht-kleinzellige Bronchialkarzinom (NSCLC) im

  12. Visual Outcome and Tumor Control After Conformal Radiotherapy for Patients With Optic Nerve Sheath Meningioma

    International Nuclear Information System (INIS)

    Arvold, Nils D.; Lessell, Simmons; Bussiere, Marc; Beaudette, Kevin; Rizzo, Joseph F.; Loeffler, Jay S.; Shih, Helen A.

    2009-01-01

    Purpose: Optic nerve sheath meningioma (ONSM) is a rare tumor that almost uniformly leads to visual dysfunction and even blindness without intervention. Because surgical extirpation carries a high risk of postoperative blindness, vision-sparing treatment strategies are desirable. Methods and Materials: We retrospectively reviewed the outcomes of 25 patients (25 optic nerves) with ONSM, treated at a single institution with conformal fractionated radiotherapy by either stereotactic photon or proton radiation. Primary endpoints were local control and visual acuity. Results: The patients presented with symptoms of visual loss (21) or orbital pain (3) or were incidentally diagnosed by imaging (3). The mean age was 44 years, and 64% were female patients. The indication for treatment was the development or progression of symptoms. Of the patients, 13 were treated with photons, 9 were treated with protons, and 3 received a combination of photons and protons. The median dose delivered was 50.4 gray equivalents (range, 45-59.4 gray equivalents). Median follow-up after radiotherapy was 30 months (range, 3-168 months), with 3 patients lost to follow-up. At most recent follow-up, 21 of 22 patients (95%) had improved (14) or stable (7) visual acuity. One patient had worsened visual acuity after initial postirradiation improvement. Of the 22 patients, 20 (95%) had no radiographic progression. Three patients had evidence of asymptomatic, limited retinopathy on ophthalmologic examination, and one had recurrent ONSM 11 years after treatment. Conclusions: Highly conformal, fractionated radiation therapy for symptomatic primary ONSM provides tumor control and improvement in visual function in most cases, with minimal treatment-induced morbidity. Longer follow-up is needed to assess the durability of tumor control and treatment-related late effects.

  13. Combined radiotherapy and chemotherapy for pediatric medulloblastoma: a clinical study of 33 cases

    Directory of Open Access Journals (Sweden)

    Wei ZHENG

    2011-06-01

    Full Text Available Objective To retrospectively review the clinical characteristics of medulloblastoma,discuss the optimized treatment regimen,and analyze the prognostic influential factors.Methods Thirty-three children with pathologically certified medulloblastoma(aged 3-14 years with average of 6.5 years,admitted from Aug.2004 to Dec.2007,received radiotherapy within 3 weeks post surgery.Ratiotherapy consisted of 28~36Gy whole craniospinal radiation and a supplementary radiation aimed at tumors by three-dimensional conformal radiotherapy(3D-CRT for a total dose of 50~54Gy(conventional fraction dose of 1.8-2.0Gy.A part of patients received hyperfractionation radiotherapy(1.0Gy/f,2f/d for alleviating the tardive adverse events.Meanwhile,a synchronized chemotherapy,consisting of lomustine + vincristine + cisplatin,or isophosphamide + carboplatin + etoposide,was administered after the completion of whole craniospinal radiation,and 3-5 courses of sequential chemotherapy were given after the overall radiotherapy was finished.According to the metastasis,and the residual tumor and its size,the 33 patients were divided into 2 groups as follows: low-risk group(n=24: no metastases,total or sub-total excision of tumors(residual tumors ≤1.5cm3;high-risk group(n=9: either metastases or residual tumor > 1.5cm3.The 3-year survival rates of two groups were then compared.Results The combined radiotherapy and chemotherapy was effective to 10 of the 11 patients(90.9% with residual tumors.Out of the 33 patients,31 obtained complete remission(93.9%,and 2 patients showed partial remission or stable status(3.0%,respectively.The median survival time of 33 patients was 51 months,3-year disease free survival(DFS was 75.8%,and 3-year overall survival(OS was 78.8%,including 33.3% in high-risk group and 95.8% in low-risk group(P < 0.01.The major side effects occurred in haematological system and digestive system,such as an incidence of 21.2%(7/33 with grade Ⅲ-Ⅳ bone marrow suppression

  14. Radiological response and dosimetry in physical phantom of head and neck for 3D conformational radiotherapy; Resposta radiologica e dosimetria em phantom fisico de cabeca e pescoco para radioterapia conformacional 3D

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Larissa

    2013-07-01

    Phantoms are tools for simulation of organs and tissues of the human body in radiology and radiotherapy. This thesis describes the development, validation and, most importantly, the use of a physical head and neck phantom in radiology and radiotherapy, with the purpose of evaluating dose distribution using Gafchromic EBT2 film in 15 MV 3D conformal radiotherapy. The work was divided in two stages, (1) development of new equivalent tissues and improvement of the physical phantom, and (2) use of the physical phantom in experimental dosimetry studies. In phase (1) parameters such as mass density, chemical composition of tissues, anatomical and biometric measurements were considered, as well as aspects of imaging by computed tomography (CT) and radiological response representation in Hounsfield Units (HU), which were compared with human data. Radiological experiments of in-phantom simulated brain pathologies were also conducted. All those results matched human-sourced data, therefore the physical phantom is a suitable simulator that may be used to enhance radiological protocols and education in medical imaging. The main objective in phase (2) was to evaluate the spatial dose distribution in a brain tumor simulator inserted inside the head and neck phantom developed by the Ionizing Radiation Research Group (NRI), exposed to 15 MV 3D conformal radiotherapy, for internal dose assessment. Radiation planning was based on CT images of the physical phantom with a brain tumor simulator made with equivalent material. The treatment planning system (TPS), CAT3D software, used CT images and prescribed a dose of 200 cGy, distributed in three fields of radiation, in a T-shaped pattern. The TPS covered the planning treatment volume (PTV) with 97% of the prescribed dose. A solid water phantom and radiochromic Gafchromic EBT2 film were used for calibration procedures, generating a dose response curve as a function of optical density (OD). After calibration and irradiation, the film

  15. A pilot survey of sexual function and quality of life following 3D conformal radiotherapy for clinically localized prostate cancer

    International Nuclear Information System (INIS)

    Roach, Mack; Chinn, Daniel M.; Holland, John; Clarke, Michelle

    1996-01-01

    Purpose: To assess the impact of high dose three-dimensional conformal radiotherapy (3D CRT) for prostate cancer on the sexual function-related quality of life of patients and their partners. Methods and Materials: Sixty of 124 consecutive patients (median age 72.3 years) treated with 3D CRT for localized prostate cancer were surveyed and reported being potent prior to treatment. The answers to survey questions assessing the impact of quality of life related to sexual function from these 60 patients and their partners forms the basis for this retrospective analysis. Results: Following 3D CRT, 37 of 60 patients (62%) retained sexual function sufficient for intercourse. Intercourse at least once per month was reduced from 71 to 40%, whereas intercourse less than once per year increased from 12 to 35%. Following treatment, 25% of patients reported that the change in sexual dysfunction negatively affected their relationship or resulted in poor self-esteem. This outcome was associated with impotence following treatment (p < 0.01). Patients who had partners and satisfactory sexual function appeared to be at a higher risk of having a negatively affected relationship or losing self-esteem if they become impotent (p < 0.05). Partners of patients who reported a negatively affected relationship or loss of self-esteem appear to be less likely to return the survey instrument used (p = 0.02). Conclusions: More work is needed to evaluate the impact of radiotherapy and other treatments on the quality of life of patients and their partners to allow adequate informed consent to be given

  16. Evaluation of homogeneity and dose conformity in IMRT planning in prostate radiotherapy; Avaliacao da homogeneidade e conformidade de dose em planejamentos de IMRT de prostata em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Juliane S.; Leidens, Matheus; Estacio, Daniela R., E-mail: juliane.lopes@pucrs.br [Hospital Sao Lucas (PUC-RS), Porto Alegre, RS (Brazil). Servico de Radioterapia; Razera, Ricardo A.Z.; Streck, Elaine E.; Silva, Ana M.M. da [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Faculdade de Fisica

    2015-12-15

    The goal of this study was to evaluate the dose distribution homogeneity and conformity of radiation therapy plans of prostate cancer using IMRT. Data from 34 treatment plans of Hospital Sao Lucas of PUCRS, where those plans were executed, were retrospectively analyzed. All of them were done with 6MV X-rays from a linear accelerator CLINAC IX, and the prescription doses varied between 60 and 74 Gy. Analyses showing the homogeneity and conformity indices for the dose distribution of those plans were made. During these analyses, some comparisons with the traditional radiation therapy planning technic, the 3D-CRT, were discussed. The results showed that there is no correlation between the prescribed dose and the homogeneity and conformity indices, indicating that IMRT works very well even for higher doses. Furthermore, a comparison between the results obtained and the recommendations of ICRU 83 was carried out. It has also been observed that the indices were really close to the ideal values. 82.4% of the cases showed a difference below 5% of the ideal value for the index of conformity, and 88.2% showed a difference below 10% for the homogeneity index. Concluding, it is possible to confirm the quality of the analyzed radiation therapy plans of prostate cancer using IMRT. (author)

  17. Hypofractionated three-dimensional conformal radiotherapy for medically inoperable early stage

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Ho; Wu, Hong Gyun; KIm, Hak Jae; Park, Charn Il; Lee, Se Hoon; Kim, Dong Wan; Heo, Dae Seong [Seoul National University College of Medicine, Seou (Korea, Republic of)

    2013-01-15

    The purpose of this study was to assess the clinical outcomes of hypofractionated radiotherapy (HFRT) with three-dimensional conformal technique for medically inoperable patients with early stage non-small-cell lung cancer (NSCLC) and to evaluate prognostic factors. We performed a retrospective review of 26 patients who underwent HFRT for early stage NSCLC between September 2005 and August 2011. Only clinical stage T1-3N0 was included. The median RT dose was 70 Gy (range, 60 to 72 Gy) and the median biologically equivalent dose (BED) was 94.5 Gy (range, 78.0 to 100.8 Gy). In 84.6% of patients, 4 Gy per fraction was used. Neoadjuvant chemotherapy with paclitaxel and cisplatin was given to 2 of 26 patients. The median follow-up time for surviving patients was 21 months (range, 13 to 49 months). The overall response rate was 53.9%, and the initial local control rate was 100%. The median survival duration was 27.8 months. Rates of 2-year overall survival, progression-free survival (PFS), local control (LC), and locoregional-free survival (LRFS) were 54.3%, 61.1%, 74.6%, and 61.9%, respectively. Multivariate analysis showed that BED (>90 vs. {<=}90 Gy) was an independent prognostic factor influencing PFS, LC, and LRFS. Severe toxicities over grade 3 were not observed. Radical HFRT can yield satisfactory disease control with acceptable rates of toxicities in medically inoperable patients with early stage NSCLC. HFRT is a viable alternative for clinics and patients ineligible for stereotactic ablative radiotherapy. BED over 90 Gy and 4 Gy per fraction might be appropriate for HFRT.

  18. Radiation therapy for gastric mucosa-associated lymphoid tissue lymphoma: Dose-volumetric analysis and its clinical implications

    International Nuclear Information System (INIS)

    Lim, Hyeon Won; Kim, Tae Hyun; Choi, Il Ju; Kim, Chan Gyoo; Lee, Jong Yeul; Cho, Soo Jeong; Eom, Hyeon Seok; Moon, Sung Ho; Kim, Dae Yong

    2016-01-01

    To assess the clinical outcomes of radiotherapy (RT) using two-dimensional (2D) and three-dimensional conformal RT (3D-CRT) for patients with gastric mucosa-associated lymphoid tissue (MALT) lymphoma to evaluate the effectiveness of involved field RT with moderate-dose and to evaluate the benefit of 3D-CRT comparing with 2D-RT. Between July 2003 and March 2015, 33 patients with stage IE and IIE gastric MALT lymphoma received RT were analyzed. Of 33 patients, 17 patients (51.5%) were Helicobacter pylori (HP) negative and 16 patients (48.5%) were HP positive but refractory to HP eradication (HPE). The 2D-RT (n = 14) and 3D-CRT (n = 19) were performed and total dose was 30.6 Gy/17 fractions. Of 11 patients who RT planning data were available, dose-volumetric parameters between 2D-RT and 3D-CRT plans was compared. All patients reached complete remission (CR) eventually and median time to CR was 3 months (range, 1 to 15 months). No local relapse occurred and one patient died with second primary malignancy. Tumor response, survival, and toxicity were not significantly different between 2D-RT and 3D-CRT (p > 0.05, each). In analysis for dose-volumetric parameters, Dmax and CI for PTV were significantly lower in 3D-CRT plans than 2D-RT plans (p < 0.05, each) and Dmean and V15 for right kidney and Dmean for left kidney were significantly lower in 3D-CRT than 2D-RT (p < 0.05, each). Our data suggested that involved field RT with moderate-dose for gastric MALT lymphoma could be promising and 3D-CRT could be considered to improve the target coverage and reduce radiation dose to the both kidneys

  19. Radiation therapy for gastric mucosa-associated lymphoid tissue lymphoma: Dose-volumetric analysis and its clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyeon Won; Kim, Tae Hyun; Choi, Il Ju; Kim, Chan Gyoo; Lee, Jong Yeul; Cho, Soo Jeong; Eom, Hyeon Seok; Moon, Sung Ho; Kim, Dae Yong [Research Institute and Hospital, National Cancer Center, Goyang (Korea, Republic of)

    2016-09-15

    To assess the clinical outcomes of radiotherapy (RT) using two-dimensional (2D) and three-dimensional conformal RT (3D-CRT) for patients with gastric mucosa-associated lymphoid tissue (MALT) lymphoma to evaluate the effectiveness of involved field RT with moderate-dose and to evaluate the benefit of 3D-CRT comparing with 2D-RT. Between July 2003 and March 2015, 33 patients with stage IE and IIE gastric MALT lymphoma received RT were analyzed. Of 33 patients, 17 patients (51.5%) were Helicobacter pylori (HP) negative and 16 patients (48.5%) were HP positive but refractory to HP eradication (HPE). The 2D-RT (n = 14) and 3D-CRT (n = 19) were performed and total dose was 30.6 Gy/17 fractions. Of 11 patients who RT planning data were available, dose-volumetric parameters between 2D-RT and 3D-CRT plans was compared. All patients reached complete remission (CR) eventually and median time to CR was 3 months (range, 1 to 15 months). No local relapse occurred and one patient died with second primary malignancy. Tumor response, survival, and toxicity were not significantly different between 2D-RT and 3D-CRT (p > 0.05, each). In analysis for dose-volumetric parameters, Dmax and CI for PTV were significantly lower in 3D-CRT plans than 2D-RT plans (p < 0.05, each) and Dmean and V15 for right kidney and Dmean for left kidney were significantly lower in 3D-CRT than 2D-RT (p < 0.05, each). Our data suggested that involved field RT with moderate-dose for gastric MALT lymphoma could be promising and 3D-CRT could be considered to improve the target coverage and reduce radiation dose to the both kidneys.

  20. A FAST MORPHING-BASED INTERPOLATION FOR MEDICAL IMAGES: APPLICATION TO CONFORMAL RADIOTHERAPY

    Directory of Open Access Journals (Sweden)

    Hussein Atoui

    2011-05-01

    Full Text Available A method is presented for fast interpolation between medical images. The method is intended for both slice and projective interpolation. It allows offline interpolation between neighboring slices in tomographic data. Spatial correspondence between adjacent images is established using a block matching algorithm. Interpolation of image intensities is then carried out by morphing between the images. The morphing-based method is compared to standard linear interpolation, block-matching-based interpolation and registrationbased interpolation in 3D tomographic data sets. Results show that the proposed method scored similar performance in comparison to registration-based interpolation, and significantly outperforms both linear and block-matching-based interpolation. This method is applied in the context of conformal radiotherapy for online projective interpolation between Digitally Reconstructed Radiographs (DRRs.

  1. Development of NTCP models for head and neck cancer patients treated with three-dimensional conformal radiotherapy for xerostomia and sticky saliva: The role of dosimetric and clinical factors

    International Nuclear Information System (INIS)

    Beetz, Ivo; Schilstra, Cornelis; Burlage, Fred R.; Koken, Phil W.; Doornaert, Patricia; Bijl, Henk P.; Chouvalova, Olga; Leemans, C. René; Bock, Geertruida H. de; Christianen, Miranda E.M.C.; Laan, Bernard F.A.M. van der; Vissink, Arjan; Steenbakkers, Roel J.H.M.; Langendijk, Johannes A.

    2012-01-01

    Purpose: The purpose of this multicentre prospective study was to investigate the significance of the radiation dose in the major and minor salivary glands, and other pre-treatment and treatment factors, with regard to the development of patient-rated xerostomia and sticky saliva among head and neck cancer (HNC) patients treated with primary (chemo-) radiotherapy ((CH)RT). Methods and materials: The study population was composed of 167 consecutive HNC patients treated with three-dimensional conformal (3D-CRT) (CH) RT. The primary endpoint was moderate to severe xerostomia (XER6m) as assessed by the EORTC QLQ-H and N35 at 6 months after completing (CH)RT. The secondary endpoint was moderate to severe sticky saliva at 6 months (STIC6 m). All organs at risk (OARs) potentially involved in salivary function were delineated on planning-CT, including the parotid, submandibular and sublingual glands and the minor glands in the soft palate, cheeks and lips. Patients with moderate to severe xerostomia or sticky saliva at baseline were excluded. The optimum number of variables for a multivariate logistic regression model was determined using a bootstrapping method. Results: The multivariate analysis showed the mean parotid dose, age and baseline xerostomia (none versus a bit) to be the most important predictors for XER6m. The risk of developing xerostomia increased with age and was higher when minor baseline xerostomia was present in comparison with patients without any xerostomia complaints at baseline. Model performance was good with an area under the curve (AUC) of 0.82. For STIC6m, the mean submandibular dose, age, the mean sublingual dose and baseline sticky saliva (none versus a bit) were most predictive for sticky saliva. The risk of developing STIC6 m increased with age and was higher when minor baseline sticky saliva was present in comparison with patients without any sticky saliva complaints at baseline. Model performance was good with an AUC of 0.84. Conclusions

  2. Changes in Pulmonary Function After Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, or Proton Beam Therapy for Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Lopez Guerra, Jose L.; Gomez, Daniel R.; Zhuang Yan; Levy, Lawrence B.; Eapen, George; Liu, Hongmei; Mohan, Radhe; Komaki, Ritsuko; Cox, James D.; Liao Zhongxing

    2012-01-01

    Purpose: To investigate the extent of change in pulmonary function over time after definitive radiotherapy for non-small-cell lung cancer (NSCLC) with modern techniques and to identify predictors of changes in pulmonary function according to patient, tumor, and treatment characteristics. Patients and Methods: We analyzed 250 patients who had received ≥60 Gy radio(chemo)therapy for primary NSCLC in 1998–2010 and had undergone pulmonary function tests before and within 1 year after treatment. Ninety-three patients were treated with three-dimensional conformal radiotherapy, 97 with intensity-modulated radiotherapy, and 60 with proton beam therapy. Postradiation pulmonary function test values were evaluated among individual patients compared with the same patient’s preradiation value at the following time intervals: 0–4 (T1), 5–8 (T2), and 9–12 (T3) months. Results: Lung diffusing capacity for carbon monoxide (DLCO) was reduced in the majority of patients along the three time periods after radiation, whereas the forced expiratory volume in 1 s per unit of vital capacity (FEV1/VC) showed an increase and decrease after radiation in a similar percentage of patients. There were baseline differences (stage, radiotherapy dose, concurrent chemotherapy) among the radiation technology groups. On multivariate analysis, the following features were associated with larger posttreatment declines in DLCO: pretreatment DLCO, gross tumor volume, lung and heart dosimetric data, and total radiation dose. Only pretreatment DLCO was associated with larger posttreatment declines in FEV1/VC. Conclusions: Lung diffusing capacity for carbon monoxide is reduced in the majority of patients after radiotherapy with modern techniques. Multiple factors, including gross tumor volume, preradiation lung function, and dosimetric parameters, are associated with the DLCO decline. Prospective studies are needed to better understand whether new radiation technology, such as proton beam therapy

  3. Five-year follow-up of health-related quality of life after intensity-modulated radiation therapy for prostate cancer

    International Nuclear Information System (INIS)

    Namiki, Shunichi; Ishidoya, Shigeto; Ito, Akihiro; Narazaki, Kakutaro; Yamada, Shogo; Takai, Yoshihiro; Arai, Yoichi; Tochigi, Tatsuo; Numata, Isao

    2009-01-01

    We evaluated health-related quality of life (HRQOL) in patients with localized prostate cancer who underwent intensity-modulated radiation therapy (IMRT) or three-field conformal radiotherapy (3DCRT). A total of 97 patients underwent 3DCRT and 36 underwent IMRT for localized prostate cancer between 2002 and 2004. We measured the general and disease-specific HRQOL with the Medical Outcomes Study 36-Item Health Survey and University of California, Los Angeles Prostate Cancer Index, respectively. There were no significant differences in the pre-operative characteristics of the two groups. The patients in the 3DCRT group were more likely to receive hormonal therapy compared with the IMRT group before and after radiation therapy (P<0.001 and P=0.011, respectively). With regard to general HRQOL domains, both the 3DCRT and IMRT group scores showed no significant difference between baseline and any of the observation periods. At 60 months after treatment, the 3DCRT group had significantly worse bowel function and bother scores than baseline (both P<0.001). On the other hand, there were no significant differences between the baseline and any of the post-treatment time periods in the IMRT group. In the 3DCRT group, sexual function remained substantially lower than the baseline level (P=0.023). The IMRT group tended to show a decrease in sexual function, which was not statistically significant (P=0.11). IMRT can provide the possibility to deliver a high irradiation dose to the prostate with satisfactory functional outcomes for long-term periods. (author)

  4. Dose-dependent changes in renal 1H-/23Na MRI after adjuvant radiochemotherapy for gastric cancer

    International Nuclear Information System (INIS)

    Haneder, Stefan; Budjan, Johannes Michael; Schoenberg, Stefan Oswald; Konstandin, Simon; Schad, Lothar Rudi; Hofheinz, Ralf Dieter; Gramlich, Veronika; Wenz, Frederik; Lohr, Frank; Boda-Heggemann, Judit

    2015-01-01

    Combined radiochemotherapy (RCT) for gastric cancer with three-dimensional conformal radiotherapy (3D-CRT) results in ablative doses to the upper left kidney, while image-guided intensity-modulated radiotherapy (IG-IMRT) allows kidney sparing despite improved target coverage. Renal function in long-term gastric cancer survivors was evaluated with 3T functional magnetic resonance imaging (MRI) including diffusion-weighted imaging (DWI) and 23 Na imaging. Five healthy volunteers and 13 patients after radiotherapy were included: 11 x IG-IMRT; 1 x 3D-CRT; 1 x ''positive control'' with stereotactic body radiotherapy (SBRT) of a metastasis between the spleen/left kidney. Radiation doses were documented for the upper/middle/lower kidney subvolumes. Late toxicity was evaluated based on CTC criteria, questionnaire, and creatinine values. Morphological sequences, DWI images, and 23 Na images were acquired using a 1 H/ 23 Na-tuned body-coil before/after intravenous water load (WL). Statistics for [ 23 Na] (concentration) and apparent diffusion coefficient (ADC) values were calculated for upper/middle/lower renal subvolumes. Corticomedullary [ 23 Na] gradients and [ 23 Na] differences after WL were determined. No major morphological alteration was detected in any patient. Minor scars were observed in the cranial subvolume of the left kidney of the 3D-CRT and the whole kidney of the control SBRT patient. All participants presented a corticomedullary [ 23 Na] gradient. After WL, a significant physiological [ 23 Na] gradient decrease (p < 0.001) was observed in all HV and IG-IMRT patients. In the cranial left kidney of the 3D-CRT patient and the positive control SBRT patient, the decrease was nonsignificant (p = 0.01, p = 0.02). ADC values were altered nonsignificantly in all renal subvolumes (all participants). Renal subvolumes with doses ≥ 35 Gy showed a reduced change of the [ 23 Na] gradient after WL (p = 0.043). No participants showed clinical renal

  5. Implications of free breathing motion assessed by 4D-computed tomography on the delivered dose in radiotherapy for esophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Duma, Marciana Nona, E-mail: Marciana.Duma@mri.tum.de [Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, München (Germany); Berndt, Johannes [Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, München (Germany); Rondak, Ina-Christine [Institute of Medical Statistics and Epidemiology, Klinikum rechts der Isar, Technische Universität München, München (Germany); Devecka, Michal; Wilkens, Jan J. [Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, München (Germany); Geinitz, Hans [Department of Radiation Oncology, Krankenhaus Barmherzige Schwestern Linz (Austria); Combs, Stephanie Elisabeth; Oechsner, Markus [Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, München (Germany)

    2015-01-01

    The aim of this study was to assess the effect of breathing motion on the delivered dose in esophageal cancer 3-dimensional (3D)-conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric modulated arc therapy (VMAT). We assessed 16 patients with esophageal cancer. All patients underwent 4D-computed tomography (4D-CT) for treatment planning. For each of the analyzed patients, 1 3D-CRT, 1 IMRT, and 1 VMAT (RapidArc—RA) plan were calculated. Each of the 3 initial plans was recalculated on the 4D-CT (for the maximum free inspiration and maximum free expiration) to assess the effect of breathing motion. We assessed the minimum dose (D{sub min}) and mean dose (D{sub mean}) to the esophagus within the planning target volume, the volume changes of the lungs, the D{sub mean} and the total lung volume receiving at least 40 Gy (V{sub 40}), and the V{sub 30}, V{sub 20}, V{sub 10}, and V{sub 5}. For the heart we assessed the D{sub mean} and the V{sub 25}. Over all techniques and all patients the change in D{sub mean} as compared with the planned D{sub mean} (planning CT [PCT]) to the esophagus was 0.48% in maximum free inspiration (CT-insp) and 0.55% in maximum free expiration (CT-exp). The D{sub min} CT-insp change was 0.86% and CT-exp change was 0.89%. The D{sub mean} change of the lungs (heart) was in CT-insp 1.95% (2.89%) and 3.88% (2.38%) in CT-exp. In all, 4 patients had a clinically relevant change of the dose (≥ 5% D{sub mean} to the heart and the lungs) between inspiration and expiration. These patients had a very cranially or caudally situated tumor. There are no relevant differences in the delivered dose to the regions of interest among the 3 techniques. Breathing motion management could be considered to achieve a better sparing of the lungs or heart in patients with cranially or caudally situated tumors.

  6. Set-up error in supine-positioned patients immobilized with two different modalities during conformal radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Fiorino, C.; Cattaneo, G.M.; Calandrino, R.; Reni, M.; Bolognesi, A.; Bonini, A.

    1998-01-01

    Background: Conformal radiotherapy requires reduced margins around the clinical target volume (CTV) with respect to traditional radiotherapy techniques. Therefore, high set-up accuracy and reproducibility are mandatory. Purpose: To investigate the effectiveness of two different immobilization techniques during conformal radiotherapy of prostate cancer with small fields. Materials and methods: 52 patients with prostate cancer were treated by conformal three- or four-field techniques with radical or adjuvant intent between November 1996 and March 1998. In total, 539 portal images were collected on a weekly basis for at least the first 4 weeks of the treatment on lateral and anterior 18 MV X-ray fields. The average number of sessions monitored per patient was 5.7 (range 4-10). All patients were immobilized with an alpha-cradle system; 25 of them were immobilized at the pelvis level (group A) and the remaining 27 patients were immobilized in the legs (group B). The shifts with respect to the simulation condition were assessed by measuring the distances between the same bony landmarks and the field edges. The global distributions of cranio-caudal (CC), posterior-anterior (PA) and left-right (LR) shifts were considered; for each patient random and systematic error components were assessed by following the procedure suggested by Bijhold et al. (Bijhold J, Lebesque JV, Hart AAM, Vijlbrief RE. Maximising set-up accuracy using portal images as applied to a conformal boost technique for prostatic cancer. Radiother. Oncol. 1992;24:261-271). For each patient the average isocentre (3D) shift was assessed as the quadratic sum of the average shifts in the three directions. Results 5 mm equal to 4.4% with respect to the 21.6% of group A (P<0.0001). This value was also better than the corresponding value found in a previously investigated group of 21 non-immobilized patients (Italia C, Fiorino C, Ciocca M, et al. Quality control by portal film analysis of the conformal radiotherapy

  7. A computer-controlled conformal radiotherapy system. III: graphical simulation and monitoring of treatment delivery

    International Nuclear Information System (INIS)

    Kessler, Marc L.; McShan, Daniel L.; Fraass, Benedick A.

    1995-01-01

    Purpose: Safe and efficient delivery of radiotherapy using computer-controlled machines requires new procedures to design and verify the actual delivery of these treatments. Graphical simulation and monitoring techniques for treatment delivery have been developed for this purpose. Methods and Materials: A graphics-based simulator of the treatment machine and a set of procedures for creating and manipulating treatment delivery scripts are used to simulate machine motions, detect collisions, and monitor machine positions during treatment. The treatment delivery simulator is composed of four components: a three-dimensional dynamic model of the treatment machine; a motion simulation and collision detection algorithm, user-interface widgets that mimic the treatment machine's control and readout devices; and an icon-based interface for creating and manipulating treatment delivery scripts. These components are used in a stand-alone fashion for interactive treatment delivery planning and integrated with a machine control system for treatment implementation and monitoring. Results: A graphics-based treatment delivery simulator and a set of procedures for planning and monitoring computer-controlled treatment delivery have been developed and implemented as part of a comprehensive computer-controlled conformal radiotherapy system. To date, these techniques have been used to design and help monitor computer-controlled treatments on a radiotherapy machine for more than 200 patients. Examples using these techniques for treatment delivery planning and on-line monitoring of machine motions during therapy are described. Conclusion: A system that provides interactive graphics-based tools for defining the sequence of machine motions, simulating treatment delivery including collision detection, and presenting the therapists with continual visual feedback from the treatment machine has been successfully implemented for routine clinical use as part of an overall system for computer

  8. Survey of Stereotactic Body Radiation Therapy in Japan by the Japan 3-D Conformal External Beam Radiotherapy Group

    International Nuclear Information System (INIS)

    Nagata, Yasushi; Hiraoka, Masahiro; Mizowaki, Takashi; Narita, Yuichiro; Matsuo, Yukinori; Norihisa, Yoshiki; Onishi, Hiroshi; Shirato, Hiroki

    2009-01-01

    Purpose: To recognize the current status of stereotactic body radiotherapy (SBRT) in Japan, using a nationwide survey conducted by the Japan 3-D Conformal External Beam Radiotherapy Group. Methods and Materials: The questionnaire was sent by mail to 117 institutions. Ninety-four institutions (80%) responded by the end of November 2005. Fifty-three institutions indicated that they have already started SBRT, and 38 institutions had been reimbursed by insurance. Results: A total of 1111 patients with histologically confirmed lung cancer were treated. Among these patients, 637 had T1N0M0 and 272 had T2N0M0 lung cancer. Metastatic lung cancer was found in 702 and histologically unconfirmed lung tumor in 291 patients. Primary liver cancer was found in 207 and metastatic liver cancer in 76 patients. The most frequent schedule used for primary lung cancer was 48Gy in 4 fractions at 22 institutions (52%), followed by 50Gy in 5 fractions at 11 institutions (26%) and 60Gy in 8 fractions at 4 institutions (10%). The tendency was the same for metastatic lung cancer. The average number of personnel involved in SBRT was 1.8 radiation oncologists, including 1.1 certified radiation oncologists, 2.8 technologists, 0.7 nurses, and 0.6 certified quality assurance personnel and 0.3 physicists. The most frequent amount of time for treatment planning was 61-120min, for quality assurance was 50-60min, and for treatment was 30min. There were 14 (0.6% of all cases) reported Grade 5 complications: 11 cases of radiation pneumonitis, 2 cases of hemoptysis, and 1 case of radiation esophagitis. Conclusion: The current status of SBRT in Japan was surveyed.

  9. Effect of Concurrent High-Dose Cisplatin Chemotherapy and Conformal Radiotherapy on Cervical Esophageal Cancer Survival

    International Nuclear Information System (INIS)

    Huang Shaohui; Lockwood, Gina; Brierley, James; Cummings, Bernard; Kim, John; Wong, Rebecca; Bayley, Andrew; Ringash, Jolie

    2008-01-01

    Purpose: To determine whether a change in treatment policy to conformal, elective nodal radiotherapy and concurrent high-dose cisplatin improved survival for cervical esophageal cancer patients. Methods and Materials: All cervical esophageal cancer patients treated between 1997 and 2005 were restaged (1983 American Joint Committee on Cancer criteria). Patients treated before 2001 (previous cohort [PC]) were compared with those treated from 2001 onward (recent cohort [RC]). The PC institutional chemoradiotherapy protocol was 54 Gy in 20 fractions within 4 weeks, with 5-fluorouracil (1,000 mg/m 2 ) on Days 1-4 and either mitomycin C (10 mg/m 2 ) or cisplatin (75 mg/m 2 ) on Day 1. The RC institutional chemoradiotherapy protocol was conformal radiotherapy, 70 Gy in 35 fractions within 7 weeks, to the primary tumor and elective nodes, with high-dose cisplatin (100 mg/m 2 ) on Days 1, 22, and 43. Results: The median follow-up was 3.1 years (PC, 8.1 and RC, 2.3). Of 71 patients (25 women and 46 men), 21 of 29 in the PC and 29 of 42 in the RC were treated curatively (curative subgroup, n = 50). Between the two groups, no differences in overall survival or locoregional relapse-free survival were seen. The overall survival rate at 2 and 5 years was 35% (range, 24-47%) and 21% (range, 12-32%) in the whole group and 46% (range 32-60%) and 28% (range, 15-42%) in the curative group, respectively. In the curative group, no statistically significant prognostic factors were found. Trends toward better locoregional relapse-free survival were seen in women (2-year rate, 73% vs. for men, 36%; p = 0.08) and in patients aged >64 years (2-year rate, 68% vs. age ≤64 years, 34%; p = 0.10). Conclusion: No survival improvement could be demonstrated after changing the treatment policy to high-dose cisplatin-based, conventionally fractionated conformal chemoradiotherapy. Female gender and older age might predict for better outcomes

  10. Conformal radiotherapy by intensity modulation of pediatrics tumors; Radiotherapie conformationnelle par modulation d'intensite des tumeurs pediatriques

    Energy Technology Data Exchange (ETDEWEB)

    Leseur, J.; Le Prise, E. [Centre Eugene-Marquis, 35 - Rennes (France); Carrie, C. [Centre Leon Berard, 69 - Lyon (France); Bernier, V. [Centre Alexis-Vautrin, 54 - Nancy (France); Beneyton, V. [Centre Paul-Strauss, 67 - Strasbourg (France); Mahe, M.A.; Supiot, S. [Centre Rene-Gauducheau, 44 - Nantes (France)

    2009-10-15

    The objective of this study is to take stock on the validated and potential indications of the conformal radiotherapy with intensity modulation ( intensity modulated radiotherapy I.M.R.T.) in pediatrics and to propose recommendations for its use as well as the adapted dose constraints. About 40 to 50% of children treated for a cancer are irradiated. The I.M.R.T., by linear accelerator or helical tomo-therapy has for aim to give a homogenous dose to the target volume and to save organs at risk. Its use in pediatrics seems particularly interesting because of the complexity of target volumes and the closeness of organs at risk. In compensation for these positive elements, the importance of low doses irradiation given in big volumes makes fear event consequences on growth and an increased incidence of secondary cancers in children suffering from tumors with high cure rates and long life expectancy. (N.C.)

  11. Conformal radiotherapy of locally advanced bile duct carcinoma; Radiotherapie conformationnelle des cholangiocarcinomes de la voie biliaire principale localement evolues

    Energy Technology Data Exchange (ETDEWEB)

    Bouras, N.; Caudry, M.; Bonnel, C.; Trouette, R.; Demeaux, H.; Maire, J.P. [Centre Hospitalier Universitaire, Hopital Saint-Andre, Service de Radiotherapie, 33 - Bordeaux (France); Saric, J.; Rullier, E. [Centre Hospitalier Universitaire, Hopital Saint-Andre, Service de Chirurgie Viscerale et de Transplantation Hepatique, 33 - Bordeaux (France)

    2002-02-01

    Purpose. - Retrospective study of 23 patients treated with conformal radiotherapy for a locally advanced bile duct carcinoma. Patients and methods. - Eight cases were irradiated after a radical resection (RO), because they were N+; seven after microscopically incomplete resection (R1) ; seven were not resected (R2). A dose of 45 of 50 Gy was delivered, followed by a boost up to 60 Gy in R1 and R2 groups. Concomitant chemotherapy was given in 15 cases. Results.-Late toxicity included a stenosis of the duodenum, and one of the biliary anastomosis. Two patients died from cholangitis, the mechanism of which remains unclear. Five patients are in complete remission, six had a local relapse, four developed a peritoneal carcinosis, and six distant metastases. Actuarial survival rate is 75%, 28% and 7% at 1, 3 and 5 years, respectively (median: 16.5 months). Seven patients are still alive with a 4 to 70 months follow-up. Survival is similar in the 3 small subgroups. The poor local control among RON+ cases might be related to the absence of a boost to the 'tumor bed'. In R1 patients, relapses were mainly distant metastases, where'as local and peritoneal recurrences predominated in R2. Conclusion. - Conformal radio-chemotherapy delivering 60 Gy represents a valuable palliative approach in locally advanced biliary carcinoma. (authors)

  12. Transabdominal ultrasonography, computed tomography and electronic portal imaging for 3-dimensional conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Jereczek-Fossa, B.A.; Orecchia, R.; Cattani, F.; Garibaldi, C.; Cambria, R.; Valenti, M.; Ciocca, M.; Zerini, D.; Boboc, G.I.; Vavassori, A.; Ivaldi, G.B.; Kowalczyk, A.; Matei, D.V.; Cobelli, O. de

    2007-01-01

    Purpose: To evaluate the feasibility and accuracy of daily B-mode acquisition and targeting ultrasound-based prostate localization (BAT trademark) and to compare it with computed tomography (CT) and electronic portal imaging (EPI) in 3-dimensional conformal radiotherapy (3-D CRT) for prostate cancer. Patients and Methods: Ten patients were treated with 3-D CRT (72 Gy/30 fractions, 2.4 Gy/fraction, equivalent to 80 Gy/40 fractions, for α/β ratio of 1.5 Gy) and daily BAT-based prostate localization. For the first 5 fractions, CT and EPI were also performed in order to compare organ-motion and set-up error, respectively. Results: 287 BAT-, 50 CT- and 46 EPI-alignments were performed. The average BAT-determined misalignments in latero-lateral, antero-posterior and cranio-caudal directions were -0.9 mm ± 3.3 mm, 1.0 mm ± 4.0 mm and -0.9 mm ± 3.8 mm, respectively. The differences between BAT- and CT-determined organ-motion in latero-lateral, antero-posterior and cranio-caudal directions were 2.7 mm ± 1.9 mm, 3.9 ± 2.8 mm and 3.4 ± 3.0 mm, respectively. Weak correlation was found between BAT- and CT-determined misalignments in antero-posterior direction, while no correlation was observed in latero-lateral and cranio-caudal directions. The correlation was more significant when only data of good image-quality patients were analyzed (8 patients). Conclusion: BAT ensures the relative positions of target are the same during treatment and in treatment plan, however, the reliability of alignment is patient-dependent. The average BAT-determined misalignments were small, confirming the prevalence of random errors in 3-D CRT. Further study is warranted in order to establish the clinical value of BAT. (orig.)

  13. Variation of clinical target volume definition in three-dimensional conformal radiation therapy for prostate cancer

    International Nuclear Information System (INIS)

    Valicenti, Richard K.; Sweet, John W.; Hauck, Walter W.; Hudes, Richard S.; Lee, Tony; Dicker, Adam P.; Waterman, Frank M.; Anne, Pramila R.; Corn, Benjamin W.; Galvin, James M.

    1999-01-01

    Purpose: Currently, three-dimensional conformal radiation therapy (3D-CRT) planning relies on the interpretation of computed tomography (CT) axial images for defining the clinical target volume (CTV). This study investigates the variation among multiple observers to define the CTV used in 3D-CRT for prostate cancer. Methods and Materials: Seven observers independently delineated the CTVs (prostate ± seminal vesicles [SV]) from the CT simulation data of 10 prostate cancer patients undergoing 3D-CRT. Six patients underwent CT simulation without the use of contrast material and serve as a control group. The other 4 had urethral and bladder opacification with contrast medium. To determine interobserver variation, we evaluated the derived volume, the maximum dimensions, and the isocenter for each examination of CTV. We assessed the reliability in the CTVs among the observers by correlating the variation for each class of measurements. This was estimated by intraclass correlation coefficient (ICC), with 1.00 defining absolute correlation. Results: For the prostate volumes, the ICC was 0.80 (95% confidence interval [CI]: 0.56-0.96). This changed to 0.92 (95% CI: 0.75-0.99) with the use of contrast material. Similarly, the maximal prostatic dimensions were reliable and improved. There was poor agreement in defining the SV. For this structure, the ICC never exceeded 0.28. The reliability of the isocenter was excellent, with the ICC exceeding 0.83 and 0.90 for the prostate ± SV, respectively. Conclusions: In 3D-CRT for prostate cancer, there was excellent agreement among multiple observers to define the prostate target volume but poor agreement to define the SV. The use of urethral and bladder contrast improved the reliability of localizing the prostate. For all CTVs, the isocenter was very reliable and should be used to compare the variation in 3D dosimetry among multiple observers

  14. Applications of three-dimensional image correlation in conformal radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Van Herk, M; Gilhuijs, K; Kwa, S; Lebesque, J; Muller, S; De Munck, J; Touw, A [Nederlands Kanker Inst. ` Antoni van Leeuwenhoekhuis` , Amsterdam (Netherlands); Kooy, H [Harvard Medical School, Boston, MA (United States)

    1995-12-01

    The development of techniques for the registration of CT, MRI and SPECT creates new possibilities for improved target volume definition and quantitative image analysis. The discussed technique is based on chamfer matching and is suitable for automatic 3-D matching of CT with CT, CT with MRI, CT with SPECT and MRI with SPECT. By integrating CT with MRI, the diagnostic qualities of MRI are combined with the geometric accuracy of the planning CT. Significant differences in the delineation of the target volume for brain, head and neck and prostate tumors were demonstrated when using integrated CT and MRI compared with using CT alone. In addition, integration of the planning CT with pre-operative scans improves knowledge of possible tumor extents. By first matching scans based on the bony anatomy and subsequently matching on an organ of study, relative motion of the organ is quantified accurately. In a study with 42 CT scans of 11 patients, magnitude and causes of prostate motion were analysed. The most important motion of the prostate is a forward-backward rotation around a point near the apex caused by rectal volume difference. Significant correlations were also found between motion of the legs and the prostate. By integrating functional images made before and after radiotherapy with the planning CT, the relation between local change of lung function and delivered dose has been quantified accurately. The technique of chamfer matching is a convenient and more accurate alternative for the use of external markers in a CT/SPECT lung damage study. Also, damage visible in diagnostic scans can be related to radiation dose, thereby improving follow-up diagnostics. It can be concluded that 3-D image integration plays an important role in assessing and improving the accuracy of radiotherapy and is therefore indispensable for conformal therapy. However, user-friendly implementation of these techniques remains to be done to facilitate clinical application on a large scale.

  15. Applications of three-dimensional image correlation in conformal radiotherapy

    International Nuclear Information System (INIS)

    Van Herk, M.; Gilhuijs, K.; Kwa, S.; Lebesque, J.; Muller, S.; De Munck, J.; Touw, A.; Kooy, H.

    1995-01-01

    The development of techniques for the registration of CT, MRI and SPECT creates new possibilities for improved target volume definition and quantitative image analysis. The discussed technique is based on chamfer matching and is suitable for automatic 3-D matching of CT with CT, CT with MRI, CT with SPECT and MRI with SPECT. By integrating CT with MRI, the diagnostic qualities of MRI are combined with the geometric accuracy of the planning CT. Significant differences in the delineation of the target volume for brain, head and neck and prostate tumors have been demonstrated when using integrated CT and MRI compared with using CT alone. In addition, integration of the planning CT with pre-operative scans improves knowledge of possible tumor extents. By first matching scans based on the bony anatomy and subsequently matching on an organ of study, relative motion of the organ is quantified accurately. In a study with 42 CT scans of 11 patients, magnitude and causes of prostate motion have been analysed. The most important motion of the prostate is a forward-backward rotation around a point near the apex caused by rectal volume difference. Significant correlations were also found between motion of the legs and the prostate. By integrating functional images made before and after radiotherapy with the planning CT, the relation between local change of lung function and delivered dose has been quantified accurately. The technique of chamfer matching is a convenient and more accurate alternative for the use of external markers in a CT/SPECT lung damage study. Also, damage visible in diagnostic scans can be related to radiation dose, thereby improving follow-up diagnostics. It can be concluded that 3-D image integration plays an important role in assessing and improving the accuracy of radiotherapy and is therefore indispensable for conformal therapy. However, user-friendly implementation of these techniques remains to be done to facilitate clinical application on a large

  16. SU-F-P-52: A Meta-Analysis of Controlled Clinical Trials Comparing Elective Nodal Irradiation with Involved-Field Irradiation for Conformal Or Intensity-Modulated Radiotherapy in Patients with Esophageal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bai, W; Zhang, R; Zhou, Z; Qiao, X [The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei (China)

    2016-06-15

    Purpose: To compare elective nodal irradiation with involved-field irradiation for three-dimensional conformal radiotherapy or intensity-modulated radiotherapy in patients with esophageal cancer by a metaanalysis. Methods: Wanfang, CNKI, VIP, CBM databases, PubMed, Embase and Cochrane Library were searched to identify the controlled clinical trials of elective nodal irradiation with involved-field irradiation for three-dimensional conformal radiotherapy or intensity-modulated radiotherapy in patients with esophageal cancer. The obtained data were analyzed using Stata 11.0. The difference between two groups was estimated by calculating the odds ratio (OR) with 95% confidence interval (95% CI). Results: A total of 12 controlled clinical trials involving 1095 esophageal cancer patients, which were selected according to inclusion and exclusion criteria, were included in this meta-analysis. The meta-analysis showed that the elective nodal irradiation group reduced the rates of out-field failure comparing with involved-field irradiation group (OR=3.727, P=0.007). However, the rates of ≥grades 3 acute radiation pneumonitis and esophagitis were significantly higher in the elective nodal irradiation group than in the involved-field irradiation group (OR=0.348, P=0.001, OR=0.385, P=0.000). 1-, 2-, 3-year local control rates (OR=0.966, P=0.837, OR=0.946, P=0.781; OR=0.732P=0.098) and 1-, 3-, 5-year survival rates were similar in the two groups ( OR=0.966, P=0.837; OR=0.946, P=0.781; OR=0.732, P=0.098; OR=0.952, P=0.756; OR=1.149, P=0.422; OR=0.768, P=0.120). It is the same with the rates of distant metastasis (OR=0.986, P=0.937). Conclusion: Compared with involved-field irradiation, the elective nodal irradiation can reduce the rates of out-field failure for three-dimensional conformal radiotherapy or intensity-modulated radiotherapy in patients with esophageal cancer. However, its advantage of local control and survival rates is not obvious and it increases the incidence

  17. A study of the radiobiological modeling of the conformal radiation therapy in cancer treatment

    Science.gov (United States)

    Pyakuryal, Anil Prasad

    Cancer is one of the leading causes of mortalities in the world. The precise diagnosis of the disease helps the patients to select the appropriate modality of the treatments such as surgery, chemotherapy and radiation therapy. The physics of X-radiation and the advanced imaging technologies such as positron emission tomography (PET) and computed tomography (CT) plays an important role in the efficient diagnosis and therapeutic treatments in cancer. However, the accuracy of the measurements of the metabolic target volumes (MTVs) in the PET/CT dual-imaging modality is always limited. Similarly the external beam radiation therapy (XRT) such as 3D conformal radiotherapy (3DCRT) and intensity modulated radiation therapy (IMRT) is the most common modality in the radiotherapy treatment. These treatments are simulated and evaluated using the XRT plans and the standard methodologies in the commercial planning system. However, the normal organs are always susceptible to the radiation toxicity in these treatments due to lack of knowledge of the appropriate radiobiological models to estimate the clinical outcomes. We explored several methodologies to estimate MTVs by reviewing various techniques of the target volume delineation using the static phantoms in the PET scans. The review suggests that the more precise and practical method of delineating PET MTV should be an intermediate volume between the volume coverage for the standardized uptake value (SUV; 2.5) of glucose and the 50% (40%) threshold of the maximum SUV for the smaller (larger) volume delineations in the radiotherapy applications. Similarly various types of optimal XRT plans were designed using the CT and PET/CT scans for the treatment of various types of cancer patients. The qualities of these plans were assessed using the universal plan-indices. The dose-volume criteria were also examined in the targets and organs by analyzing the conventional dose-volume histograms (DVHs). The biological models such as tumor

  18. Non small cells stage I bronchial cancers: three-dimensional radiotherapy and radiotherapy in stereotactic conditions; Cancers bronchiques non a petites cellules de stade I: radiotherapie tridimensionnelle et radiotherapie en conditions stereotaxiques

    Energy Technology Data Exchange (ETDEWEB)

    Schipman, B.; Bosset, J.F. [CHU, 25 - Besancon (France); Marchesi, V.; Beckendorf, V.; Desandes, E.; Peiffert, D. [CRLCC Alexis-Vautrin, 54 - Vandaeuvre-les-Nancy (France); Bosset, M. [CHU, 26 - Valence (France)

    2010-10-15

    The authors report a comparison between three-dimensional conformation radiotherapy and robotic irradiation in stereotactic conditions (with CyberKnife) for patients suffering from a bronchial cancer with no small cells of stage I. Acute and late toxicity have been recorded, and the monitoring comprised a clinic examination and a thoracic scanography. The external radiotherapy results in an important local control rate and an acceptable toxicity. Some prospective studies are still needed to compare three-dimensional conformation respiratory-gated radiotherapy and radiotherapy in stereotactic conditions. Short communication

  19. Intensity-Modulated Radiotherapy Reduces Radiation-Induced Morbidity and Improves Health-Related Quality of Life: Results of a Nonrandomized Prospective Study Using a Standardized Follow-Up Program

    International Nuclear Information System (INIS)

    Vergeer, Marije R.; Doornaert, Patricia A.H.; Rietveld, Derek H.F.; Leemans, C. Rene; Slotman, Ben J.; Langendijk, Johannes A.

    2009-01-01

    Purpose: The purpose of this study was to compare intensity-modulated radiation therapy (IMRT) and three-dimensional conventional radiotherapy (3D-CRT) with regard to patient-rated xerostomia, Radiation Therapy Oncology Group (RTOG) acute and late xerostomia and health-related quality of life (HRQoL) among patients with head and neck squamous cell carcinoma (HNSCC). Methods and Materials: Included were 241 patients with HNSCC treated with bilateral irradiation ± chemotherapy. Since 2000, all patients treated with HNSCC were included in a program, which prospectively assessed acute and late morbidity according to the RTOG and HRQoL on a routine basis at regular intervals. Before October 2004, all patients were treated with 3D-CRT (N = 150). After clinical implementation in October 2004, 91 patients received IMRT. In this study, the differences regarding RTOG toxicity, xerostomia, and other items of HRQoL were analyzed. Results: The use of IMRT resulted in a significant reduction of the mean dose of the parotid glands (27 Gy vs. 43 Gy (p < 0.001). During radiation, Grade 2 RTOG xerostomia was significantly less with IMRT than with 3D-CRT. At 6 months, the prevalence of patient-rated moderate to severe xerostomia and Grade 2 or higher RTOG xerostomia was significantly lower after IMRT versus 3D-CRT. Treatment with IMRT also had a positive effect on several general and head and neck cancer-specific HRQoL dimensions. Conclusions: IMRT results in a significant reduction of patient- and observer-rated xerostomia, as well as other head and neck symptoms, compared with standard 3D-CRT. These differences translate into a significant improvement of the more general dimensions of HRQoL.

  20. Feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in lung cancer treatment planning

    International Nuclear Information System (INIS)

    Xiao Jianghong; Zhang Hong; Gong Youling; Fu Yuchuan; Tang Bin; Wang Shichao; Jiang Qingfeng; Li Ping

    2010-01-01

    Background and purpose: To investigate the feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in 3-dimensional conformal radiotherapy (3D-CRT), stereotactic body radiation therapy (SBRT) and intensity-modulated radiotherapy (IMRT) treatment planning for lung cancers, respectively. Materials and methods: Twelve patients with bulky lung tumors and 14 patients with small lung tumors were retrospectively analyzed. Each patient took two sets of CT in the same position with active breathing control (ABC) technique before and after intravenous contrast agent (CA) injections. Bulky tumors were planned with 3D-CRT, while SBRT plans were generated for patients with small tumors based on CT scans with intravenous CA. In addition, IMRT plans were generated for patients with bulky tumors to continue on a planning study. All plans were copied and replaced on the scans without intravenous CA. The radiation doses calculated from the two sets of CTs were compared with regard to planning volumes (PTV), the organ at-risk (OAR) and the lungs using Wilcoxon's signed rank test. Results: In comparisons for 3D-CRT plans, CT scans with intravenous CA reduced the mean dose and the maximum dose of PTV with significant differences (p 95 ) for targets, respectively (p < 0.05). There was no statistical significance for lung parameters between two sets of scans in SBRT plans and IMRT plans. Conclusions: The enhanced CT scans can be used for both target delineation and treatment planning in 3D-CRT. The dose difference caused by intravenous CA is small. But for SBRT and IMRT, the minimum irradiation dose in targets may be estimated to be increased up to 2.71% while the maximum dose may be estimated to be decreased up to 1.36%. However, the difference in dose distribution in most cases were found to be clinical tolerable.

  1. Three-Dimensional Conformal Simultaneously Integrated Boost Technique for Breast-Conserving Radiotherapy

    International Nuclear Information System (INIS)

    Laan, Hans Paul van der; Dolsma, Wil V.; Maduro, John H.; Korevaar, Erik W.; Hollander, Miranda; Langendijk, Johannes A.

    2007-01-01

    Purpose: To compare the target coverage and normal tissue dose with the simultaneously integrated boost (SIB) and the sequential boost technique in breast cancer, and to evaluate the incidence of acute skin toxicity in patients treated with the SIB technique. Methods and Materials: Thirty patients with early-stage left-sided breast cancer underwent breast-conserving radiotherapy using the SIB technique. The breast and boost planning target volumes (PTVs) were treated simultaneously (i.e., for each fraction, the breast and boost PTVs received 1.81 Gy and 2.3 Gy, respectively). Three-dimensional conformal beams with wedges were shaped and weighted using forward planning. Dose-volume histograms of the PTVs and organs at risk with the SIB technique, 28 x (1.81 + 0.49 Gy), were compared with those for the sequential boost technique, 25 x 2 Gy + 8 x 2 Gy. Acute skin toxicity was evaluated for 90 patients treated with the SIB technique according to Common Terminology Criteria for Adverse Events, version 3.0. Results: PTV coverage was adequate with both techniques. With SIB, more efficiently shaped boost beams resulted in smaller irradiated volumes. The mean volume receiving ≥107% of the breast dose was reduced by 20%, the mean volume outside the boost PTV receiving ≥95% of the boost dose was reduced by 54%, and the mean heart and lung dose were reduced by 10%. Of the evaluated patients, 32.2% had Grade 2 or worse toxicity. Conclusion: The SIB technique is proposed for standard use in breast-conserving radiotherapy because of its dose-limiting capabilities, easy implementation, reduced number of treatment fractions, and relatively low incidence of acute skin toxicity

  2. Intensity-modulated radiation therapy versus three-dimensional conformal radiation therapy with concurrent nedaplatin-based chemotherapy after radical hysterectomy for uterine cervical cancer: comparison of outcomes, complications, and dose-volume histogram parameters

    International Nuclear Information System (INIS)

    Isohashi, Fumiaki; Mabuchi, Seiji; Yoshioka, Yasuo; Seo, Yuji; Suzuki, Osamu; Tamari, Keisuke; Yamashita, Michiko; Unno, Hikari; Kinose, Yasuto; Kozasa, Katsumi; Sumida, Iori; Otani, Yuki; Kimura, Tadashi; Ogawa, Kazuhiko

    2015-01-01

    The purpose of this study is to report our clinical outcomes using intensity-modulated radiation therapy (IMRT) for adjuvant treatment of cervical cancer, compared with three-dimensional conformal radiation therapy (3DCRT), in terms of tumor control, complications and dose-volume histogram (DVH) parameters. Between March 2008 and February 2014, 62 patients were treated with concurrent nedaplatin-based chemotherapy and whole-pelvic external beam radiation therapy (RT). Of these patients, 32 (52 %) received 3DCRT and 30 (48 %) received IMRT. The median follow-up periods were 40 months (range 2–74 months). The 3-year overall survival rate (OS), locoregional control rate (LRC) and progression-free survival rate (PFS) were 92, 95 and 92 % in the IMRT group, and 85, 82 and 70 % in the 3DCRT group, respectively. A comparison of OS, LRC and PFS showed no significant differences between IMRT and 3DCRT. The 3-year cumulative incidences of grade 2 or higher chronic gastrointestinal (GI) complications were significantly lower with IMRT compared to 3DCRT (3 % vs. 45 %, p < .02) and in patients with V40 of the small bowel loops of ≤340 mL compared to those with >340 mL (3 % vs. 45 %, p < .001). Patients treated with IMRT had a higher incidence of grade 3 acute hematologic complications (p < .05). V40 and V45 of the small bowel loops or bowel bag were predictive for development of both acute and chronic GI complications. Our results suggest that IMRT for adjuvant treatment of cervical cancer is useful for decreasing GI complications without worsening outcomes

  3. Dosimetric evaluation of tomography and four-box field conformal radiotherapy in locally advanced rectal cancer

    International Nuclear Information System (INIS)

    Yu, Mina; Lee, Hyo Chun; Chung, Mi Joo; Kim, Sung Hwan; Lee, Jong Hoon; Jang, Hong Seok; Jeon, Dong Min; Cheon, Geum Seong

    2013-01-01

    To report the results of dosimetric comparison between intensity-modulated radiotherapy (IMRT) using Tomotherapy and four-box field conformal radiotherapy (CRT) for pelvic irradiation of locally advanced rectal cancer. Twelve patients with locally advanced rectal cancer who received a short course preoperative chemoradiotherapy (25 Gy in 5 fractions) on the pelvis using Tomotherapy, between July 2010 and December 2010, were selected. Using their simulation computed tomography scans, Tomotherapy and four-box field CRT plans with the same dose schedule were evaluated, and dosimetric parameters of the two plans were compared. For the comparison of target coverage, we analyzed the mean dose, Vn Gy, Dmin, Dmax, radical dose homogeneity index (rDHI), and radiation conformity index (RCI). For the comparison of organs at risk (OAR), we analyzed the mean dose. Tomotherapy showed a significantly higher mean target dose than four-box field CRT (p 0.001). But, V26.25 Gy and V27.5 Gywere not significantly different between the two modalities. Tomotherapy showed higher Dmax and lower Dmin. The Tomotherapy plan had a lower rDHI than four-box field CRT (p = 0.000). Tomotherapy showed better RCI than four-box field CRT (p = 0.007). For OAR, the mean irradiated dose was significantly lower in Tomotherapy than four-box field CRT. In locally advanced rectal cancer, Tomotherapy delivers a higher conformal radiation dose to the target and reduces the irradiated dose to OAR than four-box field CRT.

  4. Dosimetric evaluation of tomography and four-box field conformal radiotherapy in locally advanced rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Mina; Lee, Hyo Chun; Chung, Mi Joo; Kim, Sung Hwan; Lee, Jong Hoon [Dept. of Radiation Oncology, St. Vincent' s Hospital, The Catholic University of Korea College of Medicine, Suwon (Korea, Republic of); Jang, Hong Seok; Jeon, Dong Min; Cheon, Geum Seong [Dept. of Radiation Oncology, Seoul St. Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2013-12-15

    To report the results of dosimetric comparison between intensity-modulated radiotherapy (IMRT) using Tomotherapy and four-box field conformal radiotherapy (CRT) for pelvic irradiation of locally advanced rectal cancer. Twelve patients with locally advanced rectal cancer who received a short course preoperative chemoradiotherapy (25 Gy in 5 fractions) on the pelvis using Tomotherapy, between July 2010 and December 2010, were selected. Using their simulation computed tomography scans, Tomotherapy and four-box field CRT plans with the same dose schedule were evaluated, and dosimetric parameters of the two plans were compared. For the comparison of target coverage, we analyzed the mean dose, Vn Gy, Dmin, Dmax, radical dose homogeneity index (rDHI), and radiation conformity index (RCI). For the comparison of organs at risk (OAR), we analyzed the mean dose. Tomotherapy showed a significantly higher mean target dose than four-box field CRT (p 0.001). But, V26.25 Gy and V27.5 Gywere not significantly different between the two modalities. Tomotherapy showed higher Dmax and lower Dmin. The Tomotherapy plan had a lower rDHI than four-box field CRT (p = 0.000). Tomotherapy showed better RCI than four-box field CRT (p = 0.007). For OAR, the mean irradiated dose was significantly lower in Tomotherapy than four-box field CRT. In locally advanced rectal cancer, Tomotherapy delivers a higher conformal radiation dose to the target and reduces the irradiated dose to OAR than four-box field CRT.

  5. Long-Term Results of Conformal Radiotherapy for Progressive Airway Amyloidosis

    Energy Technology Data Exchange (ETDEWEB)

    Truong, Minh Tam, E-mail: mitruong@bu.edu [Department of Radiation Oncology, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States); Kachnic, Lisa A. [Department of Radiation Oncology, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States); Grillone, Gregory A. [Department of Otolaryngology, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States); Bohrs, Harry K.; Lee, Richard [Department of Radiation Oncology, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States); Sakai, Osamu [Department of Radiology, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States); Berk, John L. [Department of Medicine, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States)

    2012-06-01

    Purpose: To evaluate the efficacy of conformal external beam radiotherapy (RT) for local control of progressive airway amyloidosis. Methods and Materials: We conducted a retrospective review of patients with biopsy-proven progressive airway amyloidosis treated with conformal RT between 2000 and 2006 at Boston Medical Center. The patients were evaluated for performance status and pulmonary function, with computed tomography and endoscopy after RT compared with the pretreatment studies. Local control was defined as the lack of progression of airway wall thickening on computed tomography imaging and stable endobronchial deposits by endoscopy. Results: A total of 10 symptomatic airway amyloidosis patients (3 laryngeal and 7 tracheobronchial) received RT to a median total dose of 20 Gy in 10 fractions within 2 weeks. At a median follow-up of 6.7 years (range, 1.5-10.3), 8 of the 10 patients had local control. The remaining 2 patients underwent repeat RT 6 and 8.4 months after initial RT, 1 for persistent bronchial obstruction and 1 for progression of subglottic amyloid disease with subsequent disease control. The Eastern Cooperative Oncology Group performance status improved at a median of 18 months after RT compared with the baseline values, from a median score of 2 to a median of 1 (p = .035). Airflow (forced expiratory volume in 1 second) measurements increased compared with the baseline values at each follow-up evaluation, reaching a 10.7% increase (p = .087) at the last testing (median duration, 64.8 months). Acute toxicity was limited to Grade 1-2 esophagitis, occurring in 40% of patients. No late toxicity was observed. Conclusions: RT prevented progressive amyloid deposition in 8 of 10 patients, resulting in a marginally increased forced expiratory volume in 1 second, and improved functional capacity, without late morbidity.

  6. Acute toxicity in pelvic radiotherapy; a randomised trial of conformal versus conventional treatment

    International Nuclear Information System (INIS)

    Tait, Diana M.; Nahum, Alan E.; Meyer, Lesley C.; Law, Matthew; Dearnaley, David P.; Horwich, Alan; Mayles, W. Philip; Yarnold, John R.

    1997-01-01

    Background: A prospective, randomized clinical trial to assess the effect of reducing the volume of irradiated normal tissue on acute reactions in pelvic radiotherapy accrued 266 evaluable patients between 1988 and 1993. Purpose: This is the definitive analysis to assess the differences between the conformal and conventional arms of the trial. Materials and methods: In both arms, patients were treated with 6 MV X-rays using a 3-field technique (in all but 5 cases) consisting of an anterior and two wedged lateral or posterior oblique fields; in the conventional arm, rectangular fields were employed, whereas in the conformal arm, the fields were shaped with customized blocks drawn according to the beam's-eye-view of the target volume. The most common dosage was 65 Gy in 2-Gy fractions 5 times a week, although a subgroup (of ca. bladder patients) were treated with 30-36 Gy in once-a-week 6 Gy fractions. Each patient completed a comprehensive acute toxicity scoring questionnaire concentrating on bowel and bladder problems, tiredness and nausea, before the start of treatment, weekly during and for 3 weeks after the end of treatment and then monthly for a further 2 months. Compliance was excellent. Results: There were no differences between the patients in the two arms with respect to age, gender, tumour type (52% prostate, 41% bladder, 5% rectum, 2% other) fractionation/dosage, anterior field size, weight, or baseline symptoms. Substantial differences in normal-tissue volumes (rectum, bladder, etc.) were achieved: median high-dose volume (HDV) of 689 cm 3 for the conformal technique versus 792 cm 3 for the conventional. A clear pattern of an increase in symptoms during RT, followed by a decrease after RT, was observed for the patient group as a whole. However, a very extensive analysis has not revealed any (statistically) significant differences between the two arms in level of symptoms, nor in medication prescribed. The disparity between our findings and those of other

  7. Predictors and outcomes for chronic tracheostomy after chemoradiation for advanced laryngohypopharyngeal cancer.

    Science.gov (United States)

    Jefferson, Gina D; Wenig, Barry L; Spiotto, Michael T

    2016-02-01

    After concurrent chemoradiation for head and neck squamous cell cancer, patients with laryngeal incompetence may not recover function. We assessed variables predicting tracheostomy dependence as a measure of poor laryngeal function after chemoradiation. Retrospective Analysis of 109 patients treated with chemoradiation for locoregionally advanced laryngohypopharyngeal squamous cell cancers between 1992 and 2013. Median follow-up was 17.0 and 17.2 months for tracheostomy and nontracheostomy dependent patients, respectively. For all patients, multivariate analysis demonstrated persistent tracheostomy was associated with pretreatment tracheostomy, subglottic extension, three-dimensional conformal radiotherapy (3DCRT) and postradiotherapy lymphadenectomy. When analyzed by primary site, tracheostomy dependence was associated with pretreatment tracheostomy, subglottic extension, and 3DCRT in larynx primaries, and with pretreatment tracheostomy and feeding tube dependency in hypopharynx primaries. Tracheostomy dependence did not impact local control, progression-free survival or overall survival on univariate analysis. After curative chemoradiation, long-term tracheostomy was associated with pretreatment tracheostomy, subglottic extension, postradiotherapy lymphadenectomy, and 3DCRT but did not impact outcomes. These factors may inform treatment decision making regarding organ preservation approaches for locally advanced laryngeal and hypopharyngeal cancers. 4. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Integration method of 3D MR spectroscopy into treatment planning system for glioblastoma IMRT dose painting with integrated simultaneous boost

    International Nuclear Information System (INIS)

    Ken, Soléakhéna; Cassol, Emmanuelle; Delannes, Martine; Celsis, Pierre; Cohen-Jonathan, Elizabeth Moyal; Laprie, Anne; Vieillevigne, Laure; Franceries, Xavier; Simon, Luc; Supper, Caroline; Lotterie, Jean-Albert; Filleron, Thomas; Lubrano, Vincent; Berry, Isabelle

    2013-01-01

    To integrate 3D MR spectroscopy imaging (MRSI) in the treatment planning system (TPS) for glioblastoma dose painting to guide simultaneous integrated boost (SIB) in intensity-modulated radiation therapy (IMRT). For sixteen glioblastoma patients, we have simulated three types of dosimetry plans, one conventional plan of 60-Gy in 3D conformational radiotherapy (3D-CRT), one 60-Gy plan in IMRT and one 72-Gy plan in SIB-IMRT. All sixteen MRSI metabolic maps were integrated into TPS, using normalization with color-space conversion and threshold-based segmentation. The fusion between the metabolic maps and the planning CT scans were assessed. Dosimetry comparisons were performed between the different plans of 60-Gy 3D-CRT, 60-Gy IMRT and 72-Gy SIB-IMRT, the last plan was targeted on MRSI abnormalities and contrast enhancement (CE). Fusion assessment was performed for 160 transformations. It resulted in maximum differences <1.00 mm for translation parameters and ≤1.15° for rotation. Dosimetry plans of 72-Gy SIB-IMRT and 60-Gy IMRT showed a significantly decreased maximum dose to the brainstem (44.00 and 44.30 vs. 57.01 Gy) and decreased high dose-volumes to normal brain (19 and 20 vs. 23% and 7 and 7 vs. 12%) compared to 60-Gy 3D-CRT (p < 0.05). Delivering standard doses to conventional target and higher doses to new target volumes characterized by MRSI and CE is now possible and does not increase dose to organs at risk. MRSI and CE abnormalities are now integrated for glioblastoma SIB-IMRT, concomitant with temozolomide, in an ongoing multi-institutional phase-III clinical trial. Our method of MR spectroscopy maps integration to TPS is robust and reliable; integration to neuronavigation systems with this method could also improve glioblastoma resection or guide biopsies

  9. Preliminary Toxicity Analysis of 3-Dimensional Conformal Radiation Therapy Versus Intensity Modulated Radiation Therapy on the High-Dose Arm of the Radiation Therapy Oncology Group 0126 Prostate Cancer Trial

    Energy Technology Data Exchange (ETDEWEB)

    Michalski, Jeff M., E-mail: jmichalski@radonc.wustl.edu [Department of Radiation Oncology Washington University Medical Center, St. Louis, Missouri (United States); Yan, Yan [Radiation Therapy Oncology Group Statistical Center, Philadelphia, Pennsylvania (United States); Watkins-Bruner, Deborah [Emory University School of Nursing, Atlanta, Georgia (United States); Bosch, Walter R. [Department of Radiation Oncology Washington University Medical Center, St. Louis, Missouri (United States); Winter, Kathryn [Radiation Therapy Oncology Group Statistical Center, Philadelphia, Pennsylvania (United States); Galvin, James M. [Department of Radiation Oncology Thomas Jefferson University Hospital, Philadelphia, Pennsylvania (United States); Bahary, Jean-Paul [Department of Radiation Oncology Centre Hospitalier de l' Université de Montréal-Notre Dame, Montreal, QC (Canada); Morton, Gerard C. [Department of Radiation Oncology Toronto-Sunnybrook Regional Cancer Centre, Toronto, ON (Canada); Parliament, Matthew B. [Department of Oncology Cross Cancer Institute, Edmonton, AB (Canada); Sandler, Howard M. [Department of Radiation Oncology Samuel Oschin Comprehensive Cancer Institute, Cedars-Sinai Medical Center, Los Angeles, California (United States)

    2013-12-01

    Purpose: To give a preliminary report of clinical and treatment factors associated with toxicity in men receiving high-dose radiation therapy (RT) on a phase 3 dose-escalation trial. Methods and Materials: The trial was initiated with 3-dimensional conformal RT (3D-CRT) and amended after 1 year to allow intensity modulated RT (IMRT). Patients treated with 3D-CRT received 55.8 Gy to a planning target volume that included the prostate and seminal vesicles, then 23.4 Gy to prostate only. The IMRT patients were treated to the prostate and proximal seminal vesicles to 79.2 Gy. Common Toxicity Criteria, version 2.0, and Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late morbidity scores were used for acute and late effects. Results: Of 763 patients randomized to the 79.2-Gy arm of Radiation Therapy Oncology Group 0126 protocol, 748 were eligible and evaluable: 491 and 257 were treated with 3D-CRT and IMRT, respectively. For both bladder and rectum, the volumes receiving 65, 70, and 75 Gy were significantly lower with IMRT (all P<.0001). For grade (G) 2+ acute gastrointestinal/genitourinary (GI/GU) toxicity, both univariate and multivariate analyses showed a statistically significant decrease in G2+ acute collective GI/GU toxicity for IMRT. There were no significant differences with 3D-CRT or IMRT for acute or late G2+ or 3+ GU toxicities. Univariate analysis showed a statistically significant decrease in late G2+ GI toxicity for IMRT (P=.039). On multivariate analysis, IMRT showed a 26% reduction in G2+ late GI toxicity (P=.099). Acute G2+ toxicity was associated with late G3+ toxicity (P=.005). With dose–volume histogram data in the multivariate analysis, RT modality was not significant, whereas white race (P=.001) and rectal V70 ≥15% were associated with G2+ rectal toxicity (P=.034). Conclusions: Intensity modulated RT is associated with a significant reduction in acute G2+ GI/GU toxicity. There is a trend for a

  10. Impact of the radiotherapy technique on the correlation between dose–volume histograms of the bladder wall defined on MRI imaging and dose–volume/surface histograms in prostate cancer patients

    International Nuclear Information System (INIS)

    Maggio, Angelo; Carillo, Viviana; Perna, Lucia; Fiorino, Claudio; Cozzarini, Cesare; Rancati, Tiziana; Valdagni, Riccardo; Gabriele, Pietro

    2013-01-01

    The aim of this study was to evaluate the correlation between the ‘true’ absolute and relative dose–volume histograms (DVHs) of the bladder wall, dose–wall histogram (DWH) defined on MRI imaging and other surrogates of bladder dosimetry in prostate cancer patients, planned both with 3D-conformal and intensity-modulated radiation therapy (IMRT) techniques. For 17 prostate cancer patients, previously treated with radical intent, CT and MRI scans were acquired and matched. The contours of bladder walls were drawn by using MRI images. External bladder surfaces were then used to generate artificial bladder walls by performing automatic contractions of 5, 7 and 10 mm. For each patient a 3D conformal radiotherapy (3DCRT) and an IMRT treatment plan was generated with a prescription dose of 77.4 Gy (1.8 Gy/fr) and DVH of the whole bladder of the artificial walls (DVH-5/10) and dose–surface histograms (DSHs) were calculated and compared against the DWH in absolute and relative value, for both treatment planning techniques. A specific software (VODCA v. 4.4.0, MSS Inc.) was used for calculating the dose–volume/surface histogram. Correlation was quantified for selected dose–volume/surface parameters by the Spearman correlation coefficient. The agreement between %DWH and DVH5, DVH7 and DVH10 was found to be very good (maximum average deviations below 2%, SD < 5%): DVH5 showed the best agreement. The correlation was slightly better for absolute (R = 0.80–0.94) compared to relative (R = 0.66–0.92) histograms. The DSH was also found to be highly correlated with the DWH, although slightly higher deviations were generally found. The DVH was not a good surrogate of the DWH (R < 0.7 for most of parameters). When comparing the two treatment techniques, more pronounced differences between relative histograms were seen for IMRT with respect to 3DCRT (p < 0.0001). (note)

  11. Selection of the optimal radiotherapy technique for locally advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Lee, Ik-Jae; Seong, Jinsil; Koom, Woong-Sub; Kim, Yong-Bae; Jeon, Byeong-Chul; Kim, Joo-Ho; Han, Kwang-Hyub

    2011-01-01

    Various techniques are available for radiotherapy of hepatocellular carcinoma, including three-dimensional conformal radiotherapy, linac-based intensity-modulated radiotherapy and helical tomotherapy. The purpose of this study was to determine the optimal radiotherapy technique for hepatocellular carcinoma. Between 2006 and 2007, 12 patients underwent helical tomotherapy for locally advanced hepatocellular carcinoma. Helical tomotherapy computerized radiotherapy planning was compared with the best computerized radiotherapy planning for three-dimensional conformal radiotherapy and linac-based intensity-modulated radiotherapy for the delivery of 60 Gy in 30 fractions. Tumor coverage was assessed by conformity index, radical dose homogeneity index and moderated dose homogeneity index. Computerized radiotherapy planning was also compared according to the tumor location. Tumor coverage was shown to be significantly superior with helical tomotherapy as assessed by conformity index and moderated dose homogeneity index (P=0.002 and 0.03, respectively). Helical tomotherapy showed significantly lower irradiated liver volume at 40, 50 and 60 Gy (V40, V50 and V60, P=0.04, 0.03 and 0.01, respectively). On the contrary, the dose-volume of three-dimensional conformal radiotherapy at V20 was significantly smaller than those of linac-based intensity-modulated radiotherapy and helical tomotherapy in the remaining liver (P=0.03). Linac-based intensity-modulated radiotherapy showed better sparing of the stomach compared with helical tomotherapy in the case of separated lesions in both lobes (12.3 vs. 24.6 Gy). Helical tomotherapy showed the high dose-volume exposure to the left kidney due to helical delivery in the right lobe lesion. Helical tomotherapy achieved the best tumor coverage of the remaining normal liver. However, helical tomotherapy showed much exposure to the remaining liver at the lower dose region and left kidney. (author)

  12. Dosimetric Comparison of Three-Dimensional Conformal Proton Radiotherapy, Intensity-Modulated Proton Therapy, and Intensity-Modulated Radiotherapy for Treatment of Pediatric Craniopharyngiomas

    Energy Technology Data Exchange (ETDEWEB)

    Boehling, Nicholas S. [Department of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Grosshans, David R., E-mail: dgrossha@mdanderson.org [Department of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Bluett, Jaques B. [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Palmer, Matthew T. [Department of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Song, Xiaofei; Amos, Richard A.; Sahoo, Narayan [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Meyer, Jeffrey J.; Mahajan, Anita; Woo, Shiao Y. [Department of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)

    2012-02-01

    Purpose: Cranial irradiation in pediatric patients is associated with serious long-term adverse effects. We sought to determine whether both three-dimensional conformal proton radiotherapy (3D-PRT) and intensity-modulated proton therapy (IMPT) compared with intensity-modulated radiotherapy (IMRT) decrease integral dose to brain areas known to harbor neuronal stem cells, major blood vessels, and other normal brain structures for pediatric patients with craniopharyngiomas. Methods and Materials: IMRT, forward planned, passive scattering proton, and IMPT plans were generated and optimized for 10 pediatric patients. The dose was 50.4 Gy (or cobalt Gy equivalent) delivered in 28 fractions with the requirement for planning target volume (PTV) coverage of 95% or better. Integral dose data were calculated from differential dose-volume histograms. Results: The PTV target coverage was adequate for all modalities. IMRT and IMPT yielded the most conformal plans in comparison to 3D-PRT. Compared with IMRT, 3D-PRT and IMPT plans had a relative reduction of integral dose to the hippocampus (3D-PRT, 20.4; IMPT, 51.3%{sup Asterisk-Operator }), dentate gyrus (27.3, 75.0%{sup Asterisk-Operator }), and subventricular zone (4.5, 57.8%{sup Asterisk-Operator }). Vascular organs at risk also had reduced integral dose with the use of proton therapy (anterior cerebral arteries, 33.3{sup Asterisk-Operator }, 100.0%{sup Asterisk-Operator }; middle cerebral arteries, 25.9%{sup Asterisk-Operator }, 100%{sup Asterisk-Operator }; anterior communicating arteries, 30.8{sup Asterisk-Operator }, 41.7%{sup Asterisk-Operator }; and carotid arteries, 51.5{sup Asterisk-Operator }, 77.6{sup Asterisk-Operator }). Relative reduction of integral dose to the infratentorial brain (190.7{sup Asterisk-Operator }, 109.7%{sup Asterisk-Operator }), supratentorial brain without PTV (9.6, 26.8%{sup Asterisk-Operator }), brainstem (45.6, 22.4%{sup Asterisk-Operator }), and whole brain without PTV (19.4{sup Asterisk

  13. Three dimensional conformal postoperative radiotherapy for ...

    African Journals Online (AJOL)

    Introduction: Postoperative radiotherapy of the parotid gland could be achieved with various radiotherapy techniques. However they irradiate differently the surrounding organs at risk (OARs) in particular the cochlea, oral cavity & contralateral parotid causing significant increase in the risk of oral mucositis, xerostomia, and ...

  14. Impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans

    International Nuclear Information System (INIS)

    Kubo, H. Dale; Wilder, Richard B.; Pappas, Conrad T.E.

    1999-01-01

    Purpose: The authors undertook a study to analyze the impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans. Methods and Materials: Twelve cases involving primary brain tumors, metastases, or arteriovenous malformations that had been planned with BrainLAB's conventional circular collimator-based radiosurgery system were re-planned using a β-version of BrainLAB's treatment planning software that is compatible with MRC Systems' and BrainLAB's micro-multileaf collimators. These collimators have a minimum leaf width of 1.7 mm and 3.0 mm, respectively, at isocenter. The clinical target volumes ranged from 2.7-26.1 cc and the number of static fields ranged from 3-5. In addition, for 4 prostate cancer cases, 2 separate clinical target volumes were planned using MRC Systems' and BrainLAB's micro-multileaf collimators and Varian's multileaf collimator: the smaller clinical target volume consisted of the prostate gland and the larger clinical target volume consisted of the prostate and seminal vesicles. For the prostate cancer cases, treatment plans were generated using either 6 or 7 static fields. A 'PITV ratio', which the Radiation Therapy Oncology Group defines as the volume encompassed by the prescription isodose surface divided by the clinical target volume, was used as a measure of the quality of treatment plans (a PITV ratio of 1.0-2.0 is desirable). Bladder and rectal volumes encompassed by the prescription isodose surface, isodose distributions and dose volume histograms were also analyzed for the prostate cancer patients. Results: In 75% of the cases treated with radiosurgery, a PITV ratio between 1.0-2.0 could be achieved using a micro-multileaf collimator with a leaf width of 1.7-3.0 mm at isocenter and 3-5 static fields. When the clinical target volume consisted of the prostate gland, the micro-multileaf collimator with a minimum leaf width of 3.0 mm allowed one to decrease the median volume of bladder and

  15. Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit

    International Nuclear Information System (INIS)

    Rutonjski, Laza; Petrović, Borislava; Baucal, Milutin; Teodorović, Milan; Čudić, Ozren; Gershkevitsh, Eduard; Izewska, Joanna

    2012-01-01

    Independent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT) workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes. The audit was conducted in three radiotherapy departments of Serbia. An anthropomorphic phantom was scanned with a computed tomography unit (CT) and treatment plans for eight different test cases involving various beam configurations suggested by the IAEA were prepared on local treatment planning systems (TPSs). The phantom was irradiated following the treatment plans for these test cases and doses in specific points were measured with an ionization chamber. The differences between the measured and calculated doses were reported. The measurements were conducted for different photon beam energies and TPS calculation algorithms. The deviation between the measured and calculated values for all test cases made with advanced algorithms were within the agreement criteria, while the larger deviations were observed for simpler algorithms. The number of measurements with results outside the agreement criteria increased with the increase of the beam energy and decreased with TPS calculation algorithm sophistication. Also, a few errors in the basic dosimetry data in TPS were detected and corrected. The audit helped the users to better understand the operational features and limitations of their TPSs and resulted in increased confidence in dose calculation accuracy using TPSs. The audit results indicated the shortcomings of simpler algorithms for the test cases performed and, therefore the transition to more advanced algorithms is highly desirable

  16. Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit

    Directory of Open Access Journals (Sweden)

    Rutonjski Laza

    2012-09-01

    Full Text Available Abstract Background Independent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes. Methods The audit was conducted in three radiotherapy departments of Serbia. An anthropomorphic phantom was scanned with a computed tomography unit (CT and treatment plans for eight different test cases involving various beam configurations suggested by the IAEA were prepared on local treatment planning systems (TPSs. The phantom was irradiated following the treatment plans for these test cases and doses in specific points were measured with an ionization chamber. The differences between the measured and calculated doses were reported. Results The measurements were conducted for different photon beam energies and TPS calculation algorithms. The deviation between the measured and calculated values for all test cases made with advanced algorithms were within the agreement criteria, while the larger deviations were observed for simpler algorithms. The number of measurements with results outside the agreement criteria increased with the increase of the beam energy and decreased with TPS calculation algorithm sophistication. Also, a few errors in the basic dosimetry data in TPS were detected and corrected. Conclusions The audit helped the users to better understand the operational features and limitations of their TPSs and resulted in increased confidence in dose calculation accuracy using TPSs. The audit results indicated the shortcomings of simpler algorithms for the test cases performed and, therefore the transition to more advanced algorithms is highly desirable.

  17. Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit.

    Science.gov (United States)

    Rutonjski, Laza; Petrović, Borislava; Baucal, Milutin; Teodorović, Milan; Cudić, Ozren; Gershkevitsh, Eduard; Izewska, Joanna

    2012-09-12

    Independent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT) workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes. The audit was conducted in three radiotherapy departments of Serbia. An anthropomorphic phantom was scanned with a computed tomography unit (CT) and treatment plans for eight different test cases involving various beam configurations suggested by the IAEA were prepared on local treatment planning systems (TPSs). The phantom was irradiated following the treatment plans for these test cases and doses in specific points were measured with an ionization chamber. The differences between the measured and calculated doses were reported. The measurements were conducted for different photon beam energies and TPS calculation algorithms. The deviation between the measured and calculated values for all test cases made with advanced algorithms were within the agreement criteria, while the larger deviations were observed for simpler algorithms. The number of measurements with results outside the agreement criteria increased with the increase of the beam energy and decreased with TPS calculation algorithm sophistication. Also, a few errors in the basic dosimetry data in TPS were detected and corrected. The audit helped the users to better understand the operational features and limitations of their TPSs and resulted in increased confidence in dose calculation accuracy using TPSs. The audit results indicated the shortcomings of simpler algorithms for the test cases performed and, therefore the transition to more advanced algorithms is highly desirable.

  18. Hippocampal sparing radiotherapy for pediatric medulloblastoma: impact of treatment margins and treatment technique.

    Science.gov (United States)

    Brodin, N Patrik; Munck af Rosenschöld, Per; Blomstrand, Malin; Kiil-Berthlesen, Anne; Hollensen, Christian; Vogelius, Ivan R; Lannering, Birgitta; Bentzen, Søren M; Björk-Eriksson, Thomas

    2014-04-01

    We investigated how varying the treatment margin and applying hippocampal sparing and proton therapy impact the risk of neurocognitive impairment in pediatric medulloblastoma patients compared with current standard 3D conformal radiotherapy. We included 17 pediatric medulloblastoma patients to represent the variability in tumor location relative to the hippocampal region. Treatment plans were generated using 3D conformal radiotherapy, hippocampal sparing intensity-modulated radiotherapy, and spot-scanned proton therapy, using 3 different treatment margins for the conformal tumor boost. Neurocognitive impairment risk was estimated based on dose-response models from pediatric CNS malignancy survivors and compared among different margins and treatment techniques. Mean hippocampal dose and corresponding risk of cognitive impairment were decreased with decreasing treatment margins (P < .05). The largest risk reduction, however, was seen when applying hippocampal sparing proton therapy-the estimated risk of impaired task efficiency (95% confidence interval) was 92% (66%-98%), 81% (51%-95%), and 50% (30%-70%) for 3D conformal radiotherapy, intensity-modulated radiotherapy, and proton therapy, respectively, for the smallest boost margin and 98% (78%-100%), 90% (60%-98%), and 70% (39%-90%) if boosting the whole posterior fossa. Also, the distance between the closest point of the planning target volume and the center of the hippocampus can be used to predict mean hippocampal dose for a given treatment technique. We estimate a considerable clinical benefit of hippocampal sparing radiotherapy. In choosing treatment margins, the tradeoff between margin size and risk of neurocognitive impairment quantified here should be considered.

  19. Expression of Ku70 predicts results of radiotherapy in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Tomokazu; Someya, Masanori; Hori, Masakazu; Nakata, Kensei; Kitagawa, Mio; Tsuchiya, Takaaki; Sakata, Koh-ichi [Sapporo Medical University School of medicine, Department of Radiology, Chuo-ku, Sapporo, Hokkaido (Japan); Matsumoto, Yoshihisa [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, Meguro-ku, Tokyo (Japan); Nojima, Masanori [The University of Tokyo, The Institute of Medical Science Hospital, Minatoku, Tokyo (Japan); Masumori, Naoya [Sapporo Medical University School of medicine, Department of Urology, Chuo-ku, Sapporo, Hokkaido (Japan); Hasegawa, Tadashi [Sapporo Medical University School of medicine, Department of Surgical Pathology, Chuo-ku, Sapporo, Hokkaido (Japan)

    2017-01-15

    Therapeutic strategy for prostate cancer is decided according to T stage, Gleason score, and prostate-specific antigen (PSA) level. These clinical factors are not accurate enough to predict individual risk of local failure of prostate cancer after radiotherapy. Parameters involved with radiosensitivity are required to improve the predictive capability for local relapse. We analyzed 58 patients with localized adenocarcinoma of the prostate between August 2007 and October 2010 treated with 76 Gy of intensity-modulated radiotherapy (IMRT) as a discovery cohort and 42 patients between March 2001 and May 2007 treated with three-dimensional conformal radiotherapy (3D-CRT) as a validation cohort. Immunohistochemical examination for proteins involved in nonhomologous end-joining was performed using biopsy specimens. Ku70 expression was not correlated with various clinical parameters, such as the Gleason score and D'amico risk classification, indicating that Ku70 expression was an independent prognostic factor. The predictive value for PSA relapse was markedly improved after the combination of Gleason score and Ku70 expression, as compared with Gleason score alone. In patients treated with radiotherapy and androgen deprivation therapy (ADT), no relapses were observed in patients with Gleason score ≤7 or low Ku70 expression. In contrast, patients with Gleason score ≥8 and high Ku70 expression had high PSA relapse rates. In the validation cohort, similar results were obtained. Treatment with 76 Gy and ADT can be effective for patients with Gleason score ≤7 or low Ku70 expression, but is not enough for patients with Gleason score ≥8 and high Ku70 expression and, thus, require other treatment approaches. (orig.) [German] Die Behandlung beim Prostatakarzinom ist abhaengig von T-Stadium, Gleason-Score und prostataspezifischem Antigen (PSA). Diese klinischen Faktoren sind jedoch zu ungenau, um das individuelle Lokalrezidivrisiko beim Prostatakarzinom nach

  20. Effectiveness of Educational Intervention on the Congruence of Prostate and Rectal Contouring as Compared With a Gold Standard in Three-Dimensional Radiotherapy for Prostate

    International Nuclear Information System (INIS)

    Szumacher, Ewa; Harnett, Nicole; Warner, Saar; Kelly, Valerie; Danjoux, Cyril; Barker, Ruth; Woo, Milton; Mah, Kathy; Ackerman, Ida; Dubrowski, Adam; Rose, Stuart; Crook, Juanita

    2010-01-01

    Purpose: To examine effects of a teaching intervention on precise delineation of the prostate and rectum during planning of three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Methods and Materials: A pretest, posttest, randomized controlled group design was used. During pretest all participants contoured prostate and rectum on planning CT. Afterward, they participated in two types of workshops. The experimental group engaged in an interactive teaching session focused on prostate and rectum MR anatomy compared with CT anatomy. The control group focused on 3D-CRT planning without mention of prostate or rectal contouring. The experimental group practiced on fused MR-CT images, whereas the control group practiced on CT images. All participants completed the posttest. Results: Thirty-one trainees (12 male, 19 female) were randomly assigned to two groups, 17 in the experimental arm, and 14 in the control group. Seventeen felt familiar or very familiar with pelvic organ contouring, 12 somewhat, and 2 had never done it. Thirteen felt confident with organ contouring, 13 somewhat, and 5 not confident. The demographics and composition of groups were analyzed with χ 2 and repeated-measures analysis of variance with the two groups (experimental or control) and two tests (pre- or posttest) as factors. Satisfaction with the course and long-term effects of the course on practice were assessed with immediate and delayed surveys. All performance variables showed a similar pattern of results. Conclusions: The training sessions improved the technical performance similarly in both groups. Participants were satisfied with the course content, and the delayed survey reflected that cognitively participants felt more confident with prostate and rectum contouring and would investigate opportunities to learn more about organ contouring.

  1. Hypo fractionated conformal irradiation of patients with malignant glioma

    International Nuclear Information System (INIS)

    Aboziada, M.A.; Abo-Kresha, A.E.

    2012-01-01

    Purpose: The aim of the study is to evaluate the effect of a conformal irradiation in short fractionation scheme of 49.5 Gy in 15 fractions in an overall time of 3 weeks, in terms of overall survival (OAS) and progression free survival (PFS) rates in brain glioma patients. Patients and methods: A prospective study was conducted on 54 brain glioma patients and was carried out in the Radiation Oncology Department, South Egypt Cancer Institute, Assiut University during the period from April 2006 till June 2009. Patients were treated by hypo fractionated conformal irradiation (49.5 Gy/15 fractions/3 weeks). Results: The median follow up was 23 months (range: 9-39 months). Two-year OAS and PFS rates were 68% and 60%, respectively. In univariate analysis, age > 50 years, poor performance status [Karnofasky score of >40- 50 years and glioblastoma pathology were the only independent prognostic factors that were associated with poor OAS (p = 0.003 and p = 0.004, respectively), and PFS (p = 0.027 and p = 0.011, respectively). Conclusion: Hypo fractionated conformal radiotherapy was as effective as the conventional radiotherapy, with time sparing for patients, and for radiation oncology centers. Hypo fractionated radiotherapy may be considered the radiotherapy regimen of choice in clinical practice for patients with gliomas

  2. State of the art of radiation therapy for esophageal cancer

    International Nuclear Information System (INIS)

    Itasaka, Satoshi

    2014-01-01

    Radiation therapy has a critical role in the treatment of esophageal cancer. To improve the treatment outcome of radiotherapy, not only strengthening the treatment intensity but also decreasing the long term toxicity is needed. To reduce the long term cardiopulmonary toxicity of chemoradiation, JCOG is now running a clinical trial which combines three dimensional conformal radiation therapy (3D-CRT) and mild irradiation dose. New techniques of radiation therapy, such as intensity modulated radiation therapy (IMRT) or particle therapy are also promising in both treatment intensity and decreased toxicity. (author)

  3. A phase II study of localized prostate cancer treated to 75.6 Gy with 3D conformal radiotherapy

    International Nuclear Information System (INIS)

    Nichol, Alan; Chung, Peter; Lockwood, Gina; Rosewall, Tara; Divanbiegi, Lorella; Sweet, Joan; Toi, Ants; Bayley, Andrew; Bristow, Rob; Crook, Juanita; Gospodarowicz, Mary; McLean, Michael; Milosevic, Michael; Warde, Padraig; Catton, Charles

    2005-01-01

    Background and purpose: To prospectively evaluate toxicity, biochemical failure-free survival (bFFS) and biopsy-proven local control for prostate cancer patients treated with 75.6 Gy in 42 fractions using 6-field conformal radiotherapy to prostate alone. Patients and methods: From 1997 to 1999, 140 patients with T1-2NxM0, Gleason score ≤8, and PSA ≤20 ng/ml prostate cancer were assessed using Radiation Therapy Oncology Group acute and late toxicity scores. bFFS was determined for 120 patients treated without hormones. Post-treatment prostate biopsies were performed at a median of 3 years and a late toxicity questionnaire was administered at a median of 5 years. Results: Clinically important acute toxicities were gastrointestinal (GI) grade 2: 22% and 3: 0%, and genitourinary (GU) grade 2: 24% and 3: 2%. Late physician-assessed toxicities were GI ≥grade 2: 2%, and GU ≥grade 2: 1%. The 3-year bFFS of patients failure-free before biopsy was 93% (95% CI: 83-100) from a negative biopsy and 22% (95% CI: 0-56) from a positive biopsy (P=0.001). Patients reported significantly more late toxicity than physicians (GI: P=0.003, GU: P<0.001). At 5.0 years median follow-up, cause-specific survival was 98% (95% CI: 96-100), overall survival was 91% (95% CI: 86-97), and bFFS was 55% (95% CI: 45-64). Conclusions: 75.6 Gy caused modest levels of acute and late toxicity. Three-year biopsies predicted subsequent biochemical outcome

  4. Five-Year Outcomes, Cosmesis, and Toxicity With 3-Dimensional Conformal External Beam Radiation Therapy to Deliver Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Rodríguez, Núria; Sanz, Xavier; Dengra, Josefa; Foro, Palmira; Membrive, Ismael; Reig, Anna; Quera, Jaume; Fernández-Velilla, Enric; Pera, Óscar; Lio, Jackson; Lozano, Joan; Algara, Manuel

    2013-01-01

    Purpose: To report the interim results from a study comparing the efficacy, toxicity, and cosmesis of breast-conserving treatment with accelerated partial breast irradiation (APBI) or whole breast irradiation (WBI) using 3-dimensional conformal external beam radiation therapy (3D-CRT). Methods and Materials: 102 patients with early-stage breast cancer who underwent breast-conserving surgery were randomized to receive either WBI (n=51) or APBI (n=51). In the WBI arm, 48 Gy was delivered to the whole breast in daily fractions of 2 Gy, with or without additional 10 Gy to the tumor bed. In the APBI arm, patients received 37.5 Gy in 3.75 Gy per fraction delivered twice daily. Toxicity results were scored according to the Radiation Therapy Oncology Group Common Toxicity Criteria. Skin elasticity was measured using a dedicated device (Multi-Skin-Test-Center MC-750-B2, CKelectronic-GmbH). Cosmetic results were assessed by the physician and the patients as good/excellent, regular, or poor. Results: The median follow-up time was 5 years. No local recurrences were observed. No significant differences in survival rates were found. APBI reduced acute side effects and radiation doses to healthy tissues compared with WBI (P 75% of patients in the APBI arm had excellent or good cosmesis, and these outcomes appear to be stable over time. The percentage of patients with excellent/good cosmetic results was similar in both groups. Conclusions: APBI delivered by 3D-CRT to the tumor bed for a selected group of early-stage breast cancer patients produces 5-year results similar to those achieved with conventional WBI

  5. Clinical results of conformal versus intensity-modulated radiotherapy using a focal simultaneous boost for muscle-invasive bladder cancer in elderly or medically unfit patients.

    Science.gov (United States)

    Lutkenhaus, Lotte J; van Os, Rob M; Bel, Arjan; Hulshof, Maarten C C M

    2016-03-18

    For elderly or medically unfit patients with muscle-invasive bladder cancer, cystectomy or chemotherapy are contraindicated. This leaves radical radiotherapy as the only treatment option. It was the aim of this study to retrospectively analyze the treatment outcome and associated toxicity of conformal versus intensity-modulated radiotherapy (IMRT) using a focal simultaneous tumor boost for muscle-invasive bladder cancer in patients not suitable for cystectomy. One hundred eighteen patients with T2-4 N0-1 M0 bladder cancer were analyzed retrospectively. Median age was 80 years. Treatment consisted of either a conformal box technique or IMRT and included a simultaneous boost to the tumor. To enable an accurate boost delivery, fiducial markers were placed around the tumor. Patients were treated with 40 Gy in 20 fractions to the elective treatment volumes, and a daily tumor boost up to 55-60 Gy. Clinical complete response was seen in 87 % of patients. Three-year overall survival was 44 %, with a locoregional control rate of 73 % at 3 years. Toxicity was low, with late urinary and intestinal toxicity rates grade ≥ 2 of 14 and 5 %, respectively. The use of IMRT reduced late intestinal toxicity, whereas fiducial markers reduced acute urinary toxicity. Radical radiotherapy using a focal boost is feasible and effective for elderly or unfit patients, with a 3-year locoregional control of 73 %. Toxicity rates were low, and were reduced by the use of IMRT and fiducial markers.

  6. Modelling normal tissue isoeffect distribution in conformal radiotherapy of glioblastoma provides an alternative dose escalation pattern through hypofractionation without reducing the total dose

    International Nuclear Information System (INIS)

    Mangel, L.; Skriba, Z.; Major, T.; Polgar, C.; Fodor, J.; Somogyi, A.; Nemeth, G.

    2002-01-01

    The purpose of this study was to prove that by using conformal external beam radiotherapy (RT) normal brain structures can be protected even when applying an alternative approach of biological dose escalation: hypofractionation (HOF) without total dose reduction (TDR). Traditional 2-dimensional (2D) and conformal 3-dimensional (3D) treatment plans were prepared for 10 gliomas representing the subanatomical sites of the supratentorial brain. Isoeffect distributions were generated by the biologically effective dose (BED) formula to analyse the effect of conventionally fractionated (CF) and HOF schedules on both the spatial biological dose distribution and biological dose-volume histograms. A comparison was made between 2D-CF (2.0 Gy/day) and 3D-HOF (2.5 Gy/day) regimens, applying the same 60 Gy total doses. Integral biologically effective dose (IBED) and volumes received biologically equivalent to a dose of 54 Gy or more (V-BED54) were calculated for the lower and upper brain stem as organs of risk. The IBED values were lower with the 3D-HOF than with the 2D-CF schedule in each tumour location, means 22.7±17.1 and 40.4±16.9 in Gy, respectively (p<0.0001). The V-BED54 values were also smaller or equal in 90% of the cases favouring the 3D-HOF scheme. The means were 2.7±4.8 ccm for 3D-HOF and 10.7±12.7 ccm for 2D-CF (p=0.0006). Our results suggest that with conformal RT, fraction size can gradually be increased. HOF radiotherapy regimens without TDR shorten the treatment time and seem to be an alternative way of dose escalation in the treatment of glioblastoma

  7. Modelling normal tissue isoeffect distribution in conformal radiotherapy of glioblastoma provides an alternative dose escalation pattern through hypofractionation without reducing the total dose

    Energy Technology Data Exchange (ETDEWEB)

    Mangel, L.; Skriba, Z.; Major, T.; Polgar, C.; Fodor, J.; Somogyi, A.; Nemeth, G. [National Research Inst. for Radiobiology and Radiohygiene, Budapest (Hungary)

    2002-04-01

    The purpose of this study was to prove that by using conformal external beam radiotherapy (RT) normal brain structures can be protected even when applying an alternative approach of biological dose escalation: hypofractionation (HOF) without total dose reduction (TDR). Traditional 2-dimensional (2D) and conformal 3-dimensional (3D) treatment plans were prepared for 10 gliomas representing the subanatomical sites of the supratentorial brain. Isoeffect distributions were generated by the biologically effective dose (BED) formula to analyse the effect of conventionally fractionated (CF) and HOF schedules on both the spatial biological dose distribution and biological dose-volume histograms. A comparison was made between 2D-CF (2.0 Gy/day) and 3D-HOF (2.5 Gy/day) regimens, applying the same 60 Gy total doses. Integral biologically effective dose (IBED) and volumes received biologically equivalent to a dose of 54 Gy or more (V-BED54) were calculated for the lower and upper brain stem as organs of risk. The IBED values were lower with the 3D-HOF than with the 2D-CF schedule in each tumour location, means 22.7{+-}17.1 and 40.4{+-}16.9 in Gy, respectively (p<0.0001). The V-BED54 values were also smaller or equal in 90% of the cases favouring the 3D-HOF scheme. The means were 2.7{+-}4.8 ccm for 3D-HOF and 10.7{+-}12.7 ccm for 2D-CF (p=0.0006). Our results suggest that with conformal RT, fraction size can gradually be increased. HOF radiotherapy regimens without TDR shorten the treatment time and seem to be an alternative way of dose escalation in the treatment of glioblastoma.

  8. Normal tissue complication probability: Does simultaneous integrated boost intensity-modulated radiotherapy score over other techniques in treatment of prostate adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Jothy Basu K

    2009-01-01

    Full Text Available Aim: The main objective of this study was to analyze the radiobiological effect of different treatment strategies on high-risk prostate adenocarcinoma. Materials and Methods: Ten cases of high-risk prostate adenocarcinoma were selected for this dosimetric study. Four different treatment strategies used for treating prostate cancer were compared. Conventional four-field box technique covering prostate and nodal volumes followed by three-field conformal boost (3D + 3DCRT, four-field box technique followed by intensity-modulated radiotherapy (IMRT boost (3D + IMRT, IMRT followed by IMRT boost (IMRT + IMRT, and simultaneous integrated boost IMRT (SIBIMRT were compared in terms of tumor control probability (TCP and normal tissue complication probability (NTCP. The dose prescription except for SIBIMRT was 45 Gy in 25 fractions for the prostate and nodal volumes in the initial phase and 27 Gy in 15 fractions for the prostate in the boost phase. For SIBIMRT, equivalent doses were calculated using biologically equivalent dose assuming the α/β ratio of 1.5 Gy with a dose prescription of 60.75 Gy for the gross tumor volume (GTV and 45 Gy for the clinical target volume in 25 fractions. IMRT plans were made with 15-MV equispaced seven coplanar fields. NTCP was calculated using the Lyman-Kutcher-Burman (LKB model. Results: An NTCP of 10.7 ± 0.99%, 8.36 ± 0.66%, 6.72 ± 0.85%, and 1.45 ± 0.11% for the bladder and 14.9 ± 0.99%, 14.04 ± 0.66%, 11.38 ± 0.85%, 5.12 ± 0.11% for the rectum was seen with 3D + 3DCRT, 3D + IMRT, IMRT + IMRT, and SIBIMRT respectively. Conclusions: SIBIMRT had the least NTCP over all other strategies with a reduced treatment time (3 weeks less. It should be the technique of choice for dose escalation in prostate carcinoma.

  9. Detection of radiation brain injury of malignant glioma by 1H-MRS

    International Nuclear Information System (INIS)

    Zhang Mao; Jin Haiguo; Sun Shuquan; Bu Mingwei; Su Qingxiu; Liu Guigang; Sun Baosheng

    2011-01-01

    Objective: Using proton magnetic resonance spectroscopy ( 1 H-MRS) method, to evaluate the difference of radiation brain injury between volumetric modulated arc therapy (VMAT) and three-dimensional conformal radiation therapy (3DCRT) in patients with postoperative glioma after radiation therapy. Methods: 24 patients with malignant glioma (WHOII-IV grade glioma) confirmed with clinical surgery were selected, among them 12 patients were treated with VMAT technique, and another 12 patients with 3DCRT technique, all received DT60-66GY/30-33F dose prescriptions. 1 H-MRS examination was performed to analyze the change of metabolites in the brain tissues of region of interest (ROI) before and after radiotherapy,and the ratios of NAA/ Cr, Cho / Cr, NAA / Cho were computed. Results: The dose distribution of VMAT group was superior to 3DCRT group, the NAA/Cr in two groups after radiation were decreased compared with before radiation, there was a statistically difference in NAA/Cr after radiation between two groups (P<0.01). The Cho / Cr and NAA / Cho in two groups were increased compared with before radiation;after radiation, only NAA/Cho had a statistical difference between two groups (P<0.01). Conclusion: VMAT technique is superior to 3DCTR to reduce radiation brain injury in patients with postoperative glioma. (authors)

  10. Practical recommendations for breathing-adapted radiotherapy; Bonnes pratiques pour la radiotherapie asservie a la respiration

    Energy Technology Data Exchange (ETDEWEB)

    Simon, L.; Giraud, P.; Rosenwald, J.C. [Institut Curie, Dept. d' Oncologie-radiotherapie, 75 - Paris (France); Dumas, J.L.; Lorchel, F. [CHU de Besancon, Hopital Jean-Minjoz, Service Radiotherapie, 25 - Besancon (France); Marre, D. [Institut Claudius-Regaud, Dept. des Radiations, 31 - Toulouse (France); Dupont, S. [Hopital Europeen Georges-Pompidou, Service d' Oncoradiotherapie, 75 - Paris (France); Varmenot, N. [Centre Henri-Becquerel, UnitE de Physique Medicale, 76 - Rouen (France); Ginestet, C. [Centre Leon-Berard, Dept. de Radiotherapie, 69 - Lyon (France); Caron, J. [Institut Bergonie, Dept. de Radiotherapie, 33 - Bordeaux (France); Marchesi, V. [Centre Alexis-Vautrin, Dept. de Radiotherapie, 54 - Vandoeuvre-les-Nancy (France); Ferreira, I. [Institut Gustave-Roussy, Dept. d' Oncologie Radiotherapie, 94 - Villejuif (France); Garcia, R. [Institut Sainte-Catherine, Service de Radiotherapie, 84 - Avignon (France)

    2007-06-15

    Respiration-gated radiotherapy offers a significant potential for improvement in the irradiation of tumor sites affected by respiratory motion such as lung, breast and liver tumors. An increased conformality of irradiation fields leading to decreased complications rates of organs at risk (lung, heart) is expected. Respiratory gating is in line with the need for improved precision required by radiotherapy techniques such as 3D conformal radiotherapy or intensity modulated radiotherapy. Reduction of respiratory motion can be achieved by using either breath-hold techniques or respiration synchronized gating techniques. Breath-hold techniques can be achieved with active techniques, in which airflow of the patient is temporarily blocked by a valve, or passive techniques, in which the patient voluntarily holds his/her breath. Synchronized gating techniques use external devices to predict the phase of the respiration cycle while the patient breaths freely. This work summarizes the different experiences of the centers of the STIC 2003 project. It describes the different techniques, gives an overview of the literature and proposes a practice based on our experience. (authors)

  11. Dose-modeling study to compare external beam techniques from protocol NSABP B-39/RTOG 0413 for patients with highly unfavorable cardiac anatomy

    International Nuclear Information System (INIS)

    Hiatt, Jessica R.; Evans, Suzanne B.; Price, Lori Lyn; Cardarelli, Gene A.; Di Petrillo, Thomas A.; Wazer, David E.

    2006-01-01

    Purpose: The aim of this study was to select patients with heart anatomy that is specifically unfavorable for tangential irradiation in whole-breast radiotherapy (WBRT), to be used as an experimental cohort to compare cardiac dosimetric and radiobiological parameters of three-dimensional conformal external beam accelerated partial breast irradiation (3D-CRT APBI) to WBRT with techniques as defined by the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 clinical trial. Methods and Materials: A dosimetric modeling study that compared WBRT and 3D-CRT APBI was performed on CT planning data from 8 patients with left-sided breast cancer. Highly unfavorable cardiac anatomy was defined by the measured contact of the myocardium with the anterior chest wall in the axial and para-sagittal planes. Treatment plans of WBRT and 3D-CRT APBI were generated for each patient in accordance with NSABP B-39/RTOG 0413 protocol. Dose-volume relationships of the heart, including the V 5 min (minimum dose delivered to 5% of the cardiac volume), biological effective dose (BED) of the V 5 min, and normal tissue complication probability (NTCP) were analyzed and compared. Results: Despite expected anatomic variation, significantly large differences were found favoring 3D-CRT APBI in cumulative dose-volume histograms (p 5 min (mean difference, 24.53 Gy; p 5 min (85%, p < 0.01). Conclusions: Use of 3D-CRT APBI can demonstrate improved sparing of the heart in select patients with highly unfavorable cardiac anatomy for WBRT, and may result in reduced risk of cardiac morbidity and mortality

  12. Impact of inter- and intrafraction deviations and residual set-up errors on PTV margins. Different alignment techniques in 3D conformal prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Langsenlehner, T.; Doeller, C.; Winkler, P.; Kapp, K.S.; Galle, G.

    2013-01-01

    The aim of this work was to analyze interfraction and intrafraction deviations and residual set-up errors (RSE) after online repositioning to determine PTV margins for 3 different alignment techniques in prostate cancer radiotherapy. The present prospective study included 44 prostate cancer patients with implanted fiducials treated with three-dimensional (3D) conformal radiotherapy. Daily localization was based on skin marks followed by marker detection using kilovoltage (kV) imaging and subsequent patient repositioning. Additionally, in-treatment megavoltage (MV) images were obtained for each treatment field. In an off-line analysis of 7,273 images, interfraction prostate motion, RSE after marker-based prostate localization, prostate position during each treatment session, and the effect of treatment time on intrafraction deviations were analyzed to evaluate PTV margins. Margins accounting for interfraction deviation, RSE and intrafraction motion were 14.1, 12.9, and 15.1 mm in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) direction for skin mark alignment and 9.6, 8.7, and 2.6 mm for bony structure alignment, respectively. Alignment to implanted markers required margins of 4.6, 2.8, and 2.5 mm. As margins to account for intrafraction motion increased with treatment prolongation PTV margins could be reduced to 3.9, 2.6, and 2.4 mm if treatment time was ≤ 4 min. With daily online correction and repositioning based on implanted fiducials, a significant reduction of PTV margins can be achieved. The use of an optimized workflow with faster treatment techniques such as volumetric modulated arc techniques (VMAT) could allow for a further decrease. (orig.)

  13. Realization of 3D evaluation algorithm in dose-guided radiotherapy

    International Nuclear Information System (INIS)

    Wang Yu; Li Gui; Wang Dong; Wu Yican; FDS Team

    2012-01-01

    3D evaluation algorithm instead of 2D evaluation method of clinical dose verification is highly needed for dose evaluation in Dose-guided Radiotherapy. 3D evaluation algorithm of three evaluation methods, including Dose Difference, Distance-To-Agreement and 7 Analysis, was realized by the tool of Visual C++ according to the formula. Two plans were designed to test the algorithm, plan 1 was radiation on equivalent water using square field for the verification of the algorithm's correctness; plan 2 was radiation on the emulation head phantom using conformal field for the verification of the algorithm's practicality. For plan 1, the dose difference, in the tolerance range has a pass rate of 100%, the Distance-To-Agreement and 7 analysis was of a pass rate of 100% in the tolerance range, and a pass rate of 99±1% at the boundary of range. For plan 2, the pass rate of algorithm were 88.35%, 100%, 95.07% for the three evaluation methods, respectively. It can be concluded that the 3D evaluation algorithm is feasible and could be used to evaluate 3D dose distributions in Dose-guided Radiotherapy. (authors)

  14. Two-Year and Lifetime Cost-Effectiveness of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Head-and-Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kohler, Racquel E. [Department of Health Policy and Management, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Sheets, Nathan C. [Department of Radiation Oncology, University of North Carolina Hospitals, Chapel Hill, North Carolina (United States); Wheeler, Stephanie B. [Department of Health Policy and Management, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Nutting, Chris [Royal Marsden Hospital, London, United Kindom (United Kingdom); Hall, Emma [Clinical Trials and Statistics Unit, Division of Clinical Studies, Institute of Cancer Research, London (United Kingdom); Chera, Bhishamjit S., E-mail: bchera@med.unc.edu [Department of Radiation Oncology, University of North Carolina Hospitals, Chapel Hill, North Carolina (United States)

    2013-11-15

    Purpose: To assess the cost-effectiveness of intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3D-CRT) in the treatment of head-and neck-cancer (HNC). Methods and Materials: We used a Markov model to simulate radiation therapy-induced xerostomia and dysphagia in a hypothetical cohort of 65-year-old HNC patients. Model input parameters were derived from PARSPORT (CRUK/03/005) patient-level trial data and quality-of-life and Medicare cost data from published literature. We calculated average incremental cost-effectiveness ratios (ICERs) from the US health care perspective as cost per quality-adjusted life-year (QALY) gained and compared our ICERs with current cost-effectiveness standards whereby treatment comparators less than $50,000 per QALY gained are considered cost-effective. Results: In the first 2 years after initial treatment, IMRT is not cost-effective compared with 3D-CRT, given an average ICER of $101,100 per QALY gained. However, over 15 years (remaining lifetime on the basis of average life expectancy of a 65-year-old), IMRT is more cost-effective at $34,523 per QALY gained. Conclusion: Although HNC patients receiving IMRT will likely experience reduced xerostomia and dysphagia symptoms, the small quality-of-life benefit associated with IMRT is not cost-effective in the short term but may be cost-effective over a patient's lifetime, assuming benefits persist over time and patients are healthy and likely to live for a sustained period. Additional data quantifying the long-term benefits of IMRT, however, are needed.

  15. A Prospective Evaluation of Helical Tomotherapy

    International Nuclear Information System (INIS)

    Bauman, Glenn; Yartsev, Slav; Rodrigues, George; Lewis, Craig; Venkatesan, Varagur M.; Yu, Edward; Hammond, Alex; Perera, Francisco; Ash, Robert; Dar, A. Rashid; Lock, Michael; Baily, Laura; Coad, Terry C; Trenka, Kris C.; Warr, Barbara; Kron, Tomas; Battista, Jerry; Van Dyk, Jake

    2007-01-01

    Purpose: To report results from two clinical trials evaluating helical tomotherapy (HT). Methods and Materials: Patients were enrolled in one of two prospective trials of HT (one for palliative and one for radical treatment). Both an HT plan and a companion three-dimensional conformal radiotherapy (3D-CRT) plan were generated. Pretreatment megavoltage computed tomography was used for daily image guidance. Results: From September 2004 to January 2006, a total of 61 sites in 60 patients were treated. In all but one case, a clinically acceptable tomotherapy plan for treatment was generated. Helical tomotherapy plans were subjectively equivalent or superior to 3D-CRT in 95% of plans. Helical tomotherapy was deemed equivalent or superior in two thirds of dose-volume point comparisons. In cases of inferiority, differences were either clinically insignificant and/or reflected deliberate tradeoffs to optimize the HT plan. Overall imaging and treatment time (median) was 27 min (range, 16-91 min). According to a patient questionnaire, 78% of patients were satisfied to very satisfied with the treatment process. Conclusions: Helical tomotherapy demonstrated clear advantages over conventional 3D-CRT in this diverse patient group. The prospective trials were helpful in deploying this technology in a busy clinical setting

  16. Adjuvant Chemoradiation for Gastric Cancer Using Epirubicin, Cisplatin, and 5-Fluorouracil Before and After Three-Dimensional Conformal Radiotherapy With Concurrent Infusional 5-Fluorouracil: A Multicenter Study of the Trans-Tasman Radiation Oncology Group

    International Nuclear Information System (INIS)

    Leong, Trevor; Joon, Daryl Lim; Willis, David; Jayamoham, Jayasingham; Spry, Nigel; Harvey, Jennifer; Di Iulio, Juliana; Milner, Alvin; Mann, G. Bruce; Michael, Michael

    2011-01-01

    Purpose: The INT0116 study has established postoperative chemoradiotherapy as the standard of care for completely resected gastric adenocarcinoma. However, the optimal chemoradiation regimen remains to be defined. We conducted a prospective, multicenter study to evaluate an alternative chemoradiation regimen that combines more current systemic treatment with modern techniques of radiotherapy delivery. Methods and Materials: Patients with adenocarcinoma of the stomach who had undergone an R0 resection were eligible. Adjuvant therapy consisted of one cycle of epirubicin, cisplatin, and 5-FU (ECF), followed by radiotherapy with concurrent infusional 5-FU, and then two additional cycles of ECF. Radiotherapy was delivered using precisely defined, multiple-field, three-dimensional conformal techniques. Results: A total of 54 assessable patients were enrolled from 19 institutions. The proportion of patients commencing Cycles 1, 2, and 3 of ECF chemotherapy were 100%, 81%, and 67% respectively. In all, 94% of patients who received radiotherapy completed treatment as planned. Grade 3/4 neutropenia occurred in 66% of patients with 7.4% developing febrile neutropenia. Most neutropenic episodes (83%) occurred in the post-radiotherapy period during cycles 2 and 3 of ECF. Grade 3/4 gastrointestinal toxicity occurred in 28% of patients. In all, 35% of radiotherapy treatment plans contained protocol deviations that were satisfactorily amended before commencement of treatment. At median follow-up of 36 months, the 3-year overall survival rate was estimated at 61.6%. Conclusions: This adjuvant regimen using ECF before and after three-dimensional conformal chemoradiation is feasible and can be safely delivered in a cooperative group setting. A regimen similar to this is currently being compared with the INT0116 regimen in a National Cancer Institute-sponsored, randomized Phase III trial.

  17. Intensity modulated radiation therapy (IMRT: differences in target volumes and improvement in clinically relevant doses to small bowel in rectal carcinoma

    Directory of Open Access Journals (Sweden)

    Delclos Marc E

    2011-06-01

    Full Text Available Abstract Background A strong dose-volume relationship exists between the amount of small bowel receiving low- to intermediate-doses of radiation and the rates of acute, severe gastrointestinal toxicity, principally diarrhea. There is considerable interest in the application of highly conformal treatment approaches, such as intensity-modulated radiation therapy (IMRT, to reduce dose to adjacent organs-at-risk in the treatment of carcinoma of the rectum. Therefore, we performed a comprehensive dosimetric evaluation of IMRT compared to 3-dimensional conformal radiation therapy (3DCRT in standard, preoperative treatment for rectal cancer. Methods Using RTOG consensus anorectal contouring guidelines, treatment volumes were generated for ten patients treated preoperatively at our institution for rectal carcinoma, with IMRT plans compared to plans derived from classic anatomic landmarks, as well as 3DCRT plans treating the RTOG consensus volume. The patients were all T3, were node-negative (N = 1 or node-positive (N = 9, and were planned to a total dose of 45-Gy. Pairwise comparisons were made between IMRT and 3DCRT plans with respect to dose-volume histogram parameters. Results IMRT plans had superior PTV coverage, dose homogeneity, and conformality in treatment of the gross disease and at-risk nodal volume, in comparison to 3DCRT. Additionally, in comparison to the 3DCRT plans, IMRT achieved a concomitant reduction in doses to the bowel (small bowel mean dose: 18.6-Gy IMRT versus 25.2-Gy 3DCRT; p = 0.005, bladder (V40Gy: 56.8% IMRT versus 75.4% 3DCRT; p = 0.005, pelvic bones (V40Gy: 47.0% IMRT versus 56.9% 3DCRT; p = 0.005, and femoral heads (V40Gy: 3.4% IMRT versus 9.1% 3DCRT; p = 0.005, with an improvement in absolute volumes of small bowel receiving dose levels known to induce clinically-relevant acute toxicity (small bowel V15Gy: 138-cc IMRT versus 157-cc 3DCRT; p = 0.005. We found that the IMRT treatment volumes were typically larger than that

  18. Targetting in atelectatic lung by positron emission tomography in non-small cell lung cancer patients treated with three-dimensional conformal radiation therapy

    International Nuclear Information System (INIS)

    Wang Kai; Wang Luhua; Liang Jun; Ou Guangfei; Lu Jima

    2006-01-01

    Objective: To investigate the potential benefit of incorporating fluorodeoxyglucose positron e- mission tomography (FDG PET) to delineate tire gross tumor volume(GTV) in patients with non-small cell lung cancer (NSCLC) complicated with atelectasis who are to be treated with three-dimensional conformal radiation therapy (3DCRT). Methods: Fourteen patients histopathologically proven as having NSCLC with image diagnosed as complicated with various degrees were studied in this study. All patients were scanned with both thoracic CT and thoracic or whole body PET. The GTV was delineated basing on both CT image and PET image (CT-GTV, PET- GTV) and the volume of each GTV(designated CT-GTV and PET-GTV) was compared by 3DCRT plan. Results: Each paired CT-GTV and PET-GTV was different from each other. All patients' GTV was reduced to an average of 27 cm 3 (20.4%) with median CT-PET of 133 cm 3 (90-180 cm 3 ) and median PET-GTV of 106 cm 3 , with a in- crease of 16.9%, 22 cm 3 ). The reduction of PET-GTV was due to PET could so differ cancer-induced atelectasis from gross tumor that it reduced the tarbet volume and spared more surrounding normal tissues. Conclusions: The incorporation of FDG PET data with gross tumor delineation is able to improve the accuracy of 3DCRT for non-small cell lung cancer patients complicated with atelectasis. (authors)

  19. Three dimensional conformal radiotherapy for the treatment of prostate cancer: low risk of chronic rectal morbidity observed in a large series of patients

    International Nuclear Information System (INIS)

    Sandler, Howard M.; McLaughlin, P. William; Ten Haken, Randall K.; Addison, Heather; Forman, Jeffrey; Lichter, Allen

    1995-01-01

    Purpose: Three dimensional conformal radiotherapy (3D CRT) may provide a technique to increase the dose delivered to target tissues while sparing uninvolved normal structures. To evaluate the role of 3D treatment in reducing the treatment toxicity, we analyzed the chronic rectal morbidity observed in a large group of patients undergoing radiotherapy for prostate cancer. Methods and Materials: From 1987 through 1992, 721 prostate cancer patients were treated with 3D CRT at the University of Michigan or Providence Hospital. All had axial computed tomography (CT) specifically for RT planning, multiple structures contoured on the axial images, and beam's-eye-view conformal beams edited to provide 3D dose coverage. Using current American Joint Commission (AJCC) staging, 537 patients had T1-T2 tumors, 123 had T3-T4 tumors, and 60 were treated postprostatectomy. Pelvic lymph nodes were treated in 462 patients. Prostate boosts were delivered with four-field axial, six-field axial, or four-field oblique, nonaxial fields. The median dose was 68.40 Gy (range 59.4-80.4). Median follow-up was 20.4 months; 175 were followed more than 3 years. All complications have been graded conservatively using the RTOG system. Results: Using a Cox proportional hazard's model, patient age, T-stage, prescribed dose, pelvic treatment, and boost technique were analyzed. The factor most strongly related to risk of morbidity was dose (p = 0.05); however, the boost technique was also related: the four-field oblique field had the lowest relative risk. Most episodes of rectal morbidity have been mild: 82 Grade 1 or 2. There have been only 14 more serious complications including 12 Grade 3 and 2 Grade 4. The actuarial risk of a Grade 3 or 4 complication is 3% at 3 and 5 years. Conclusions: A very small proportion of patients treated with 3D CRT had significant rectal morbidity related to RT, supporting the use of conformal treatment planning and dose delivery as a mechanism to minimize complications

  20. Optimization by visualization of indices

    Energy Technology Data Exchange (ETDEWEB)

    Haverkamp, Uwe; Kriz, Jan; Eich, Hans Theodor [University Muenster, Department of Radiotherapy, Muenster (Germany); Norkus, Darius [Vilnius University, Oncology Institute, Vilnius (Lithuania); Mueller Minai, Mariam; Prott, Franz-Josef [RNS Radiotherapy Wiesbaden, Wiesbaden (Germany)

    2014-11-15

    Physical 3D treatment planning provides a pool of parameters describing dose distributions. It is often useful to define conformal indices to enable quicker evaluation. However, the application of individual indices is controversial and not always effective. The aim of this study was to design a quick check of dose distributions based on several indices detecting underdosages within planning target volumes (PTVs) and overdosages in normal tissue. Dose distributions of 215 cancer patients were considered. Treatment modalities used were three-dimensional conformal radiotherapy (3DCRT), radiosurgery, intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (IMAT) and tomotherapy. The volumes recommended in ICRU 50 and 83 were used for planning and six conformation and homogeneity indices were selected: CI, CN, C{sub ICRU}, COV, C{sub ∇}, and HI. These were based on the PTV, the partial volume covered by the prescribed isodose (PI; PTV{sub PI}), the treated volume (TV{sub PI}), near maximum D{sub 2} and near minimum D{sub 98}. Results were presented as a hexagon - the corners of which represent the values of the indices - and a modified test function F (Rosenbrock's function) was calculated. Results refer to clinical examples and mean values, in order to allow evaluation of the power of F and hexagon-based decision support procedures in detail and in general. IMAT and tomotherapy showed the best values for the indices and the lowest standard deviation followed by static IMRT. DCRT and radiosurgery (e.g. CN: IMAT 0.85 ± 0.06; tomotherapy 0.84 ± 0.06; IMRT 0.83 ± 0.07; 3DCRT 0.65 ± 0.08; radiosurgery 0.64 ± 0.11). In extreme situations, not all indices reflected the situation correctly. Over- and underdosing of PTV and normal tissue could be qualitatively assessed from the distortion of the hexagon in graphic analysis. Tomotherapy, IMRT, IMAT, 3DCRT and radiosurgery showed increasingly distorted hexagons, the type of distortion indicating