WorldWideScience

Sample records for confidence manually validated

  1. Lumbar segmental instability: a criterion-related validity study of manual therapy assessment

    Directory of Open Access Journals (Sweden)

    Chapple Cathy

    2005-11-01

    Full Text Available Abstract Background Musculoskeletal physiotherapists routinely assess lumbar segmental motion during the clinical examination of a patient with low back pain. The validity of manual assessment of segmental motion has not, however, been adequately investigated. Methods In this prospective, multi-centre, pragmatic, diagnostic validity study, 138 consecutive patients with recurrent or chronic low back pain (R/CLBP were recruited. Physiotherapists with post-graduate training in manual therapy performed passive accessory intervertebral motion tests (PAIVMs and passive physiological intervertebral motion tests (PPIVMs. Consenting patients were referred for flexion-extension radiographs. Sagittal angular rotation and sagittal translation of each lumbar spinal motion segment was measured from these radiographs, and compared to a reference range derived from a study of 30 asymptomatic volunteers. Motion beyond two standard deviations from the reference mean was considered diagnostic of rotational lumbar segmental instability (LSI and translational LSI. Accuracy and validity of the clinical assessments were expressed using sensitivity, specificity, and likelihood ratio statistics with 95% confidence intervals (CI. Results Only translation LSI was found to be significantly associated with R/CLBP (p Conclusion This study provides the first evidence reporting the concurrent validity of manual tests for the detection of abnormal sagittal planar motion. PAIVMs and PPIVMs are highly specific, but not sensitive, for the detection of translation LSI. Likelihood ratios resulting from positive test results were only moderate. This research indicates that manual clinical examination procedures have moderate validity for detecting segmental motion abnormality.

  2. The Manual Work Instability Scale: development and validation.

    Science.gov (United States)

    Gilworth, G; Smyth, M G; Smith, J; Tennant, A

    2016-06-01

    Increasing awareness of the burden of absenteeism and reduced performance at work highlights the importance of early identification of individuals experiencing work instability (WI), a mismatch between functional and cognitive abilities and job demands. To develop and validate a screening questionnaire to measure WI in manual workers. Questionnaire items were generated via qualitative interviews with manual workers and a draft survey instrument was completed by workers in a variety of fields. Rasch analysis was used interactively to assess the psychometric aspects of the emerging scale, including unidimensionality and absence of item bias (differential item functioning). A total of 17 qualitative interviews generated 110 potential items for the questionnaire. The item set resolved to a 25-item scale, which satisfied model expectations (item residual mean = -0.13, SD = 1.04; person residual mean = -0.29, SD = 0.75), had good reliability (alpha = 0.86) and strict unidimensionality (t-test 7.5% confidence interval 3.8-11.2). The Manual Work Instability Scale is a short psychometrically robust questionnaire based on the concept of WI, which incorporates both musculoskeletal symptoms and relevant psychosocial factors. It may prove effective in screening and identifying WI in workers in predominantly physical occupations. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. A high confidence, manually validated human blood plasma protein reference set

    DEFF Research Database (Denmark)

    Schenk, Susann; Schoenhals, Gary J; de Souza, Gustavo

    2008-01-01

    BACKGROUND: The immense diagnostic potential of human plasma has prompted great interest and effort in cataloging its contents, exemplified by the Human Proteome Organization (HUPO) Plasma Proteome Project (PPP) pilot project. Due to challenges in obtaining a reliable blood plasma protein list......-trap-Fourier transform (LTQ-FT) and a linear ion trap-Orbitrap (LTQ-Orbitrap) for mass spectrometry (MS) analysis. Both instruments allow the measurement of peptide masses in the low ppm range. Furthermore, we employed a statistical score that allows database peptide identification searching using the products of two...... consecutive stages of tandem mass spectrometry (MS3). The combination of MS3 with very high mass accuracy in the parent peptide allows peptide identification with orders of magnitude more confidence than that typically achieved. RESULTS: Herein we established a high confidence set of 697 blood plasma proteins...

  4. Wheelchair skills training to improve confidence with using a manual wheelchair among older adults: a pilot study.

    Science.gov (United States)

    Sakakibara, Brodie M; Miller, William C; Souza, Melanie; Nikolova, Viara; Best, Krista L

    2013-06-01

    To examine the effects of wheelchair skills training on confidence in older adults who are inexperienced wheelchair users. Parallel group, single-blind randomized controlled trial. Research laboratory in a rehabilitation hospital. Participants (N=20) who were community-living older adults at least 65 years old (mean age, 70y), 50% women, and who had no experience of using a wheelchair were randomly allocated to an intervention (n=10) or control (n=10) group. The intervention group received two 1-hour training sessions that followed the Wheelchair Skills Training Program (WSTP) protocol. The control group received a single socialization contact. The Wheelchair Use Confidence Scale-Manual (WheelCon-M) was used to evaluate confidence with using a manual wheelchair. The WheelCon-M is a self-report questionnaire that comprises 65 items in 6 conceptual areas. A 1-way between-groups analysis of covariance revealed a significant difference in postintervention WheelCon-M scores between the intervention and control groups (F1,17=10.9, P=.004) after controlling for baseline WheelCon-M scores. A large effect size was also observed (partial η(2)=.39). Secondary analyses revealed that the WSTP had greater effects on confidence in areas related to maneuvering around the physical environment, knowledge and problem solving, advocacy, and managing emotions than in areas related to performing activities and behaving in social situations. Two 1-hour WSTP sessions improve confidence with using a manual wheelchair among older adults who are inexperienced wheelchair users. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Thought confidence as a determinant of persuasion: the self-validation hypothesis.

    Science.gov (United States)

    Petty, Richard E; Briñol, Pablo; Tormala, Zakary L

    2002-05-01

    Previous research in the domain of attitude change has described 2 primary dimensions of thinking that impact persuasion processes and outcomes: the extent (amount) of thinking and the direction (valence) of issue-relevant thought. The authors examined the possibility that another, more meta-cognitive aspect of thinking is also important-the degree of confidence people have in their own thoughts. Four studies test the notion that thought confidence affects the extent of persuasion. When positive thoughts dominate in response to a message, increasing confidence in those thoughts increases persuasion, but when negative thoughts dominate, increasing confidence decreases persuasion. In addition, using self-reported and manipulated thought confidence in separate studies, the authors provide evidence that the magnitude of the attitude-thought relationship depends on the confidence people have in their thoughts. Finally, the authors also show that these self-validation effects are most likely in situations that foster high amounts of information processing activity.

  6. Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

    Directory of Open Access Journals (Sweden)

    Nussbaumer Silvio

    2010-08-01

    Full Text Available Abstract Background The aims of this study were to evaluate the construct validity (known group, concurrent validity (criterion based and test-retest (intra-rater reliability of manual goniometers to measure passive hip range of motion (ROM in femoroacetabular impingement patients and healthy controls. Methods Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study. Results The goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees; P P Conclusions The present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.

  7. Validation of self - confidence scale for clean urinary intermittent self - catheterization for patients and health - caregivers.

    Science.gov (United States)

    Biaziolo, Cintia Fernandes Baccarin; Mazzo, Alessandra; Martins, José Carlos Amado; Jorge, Beatriz Maria; Batista, Rui Carlos Negrão; Tucci, Silvio Júnior

    2017-01-01

    To validate a measurement instrument for clean intermittent self-catheterization for patients and health-caregivers. Methodological study of instrument validation performed at a Rehabilitation Center in a University hospital for patients submitted to clean intermittent self-catheterization and their health-caregivers. Following ethical criteria, data were collected during interview with nurse staff using a Likert question form containing 16 items with 5 points each: "no confidence"=1, "little confidence"=2, "confident"=3, "very confident"=4 and "completely confident"=5. Questionnaire called "Self- Confident Scale for Clean Intermittent Self-catheterization" (SCSCISC) was constructed based on literature and previously validated (appearance and content). The instrument was validated by 122 patients and 119 health-caregivers, in a proportion of 15:1. It was observed a good linear association and sample adequacy KMO 0.931 and X2=2881.63, p<0.001. Anti-image matrix showed high values at diagonal suggesting inclusion of all factors. Screen plot analysis showed a suggestion of items maintenance in a single set. It was observed high correlation of all items with the total, alpha-Cronbach 0.944. The same results were obtained in subsamples of patients and health-caregivers. The instrument showed good psychometric adequacy corroborating its use for evaluation of self-confidence during clean intermittent self-catheterization. Copyright® by the International Brazilian Journal of Urology.

  8. RisoeScan 1.0 - User manual and toolset for retrospective validation

    Energy Technology Data Exchange (ETDEWEB)

    Helt-Hansen, J

    2004-12-01

    The RisoeScan software is used for dose measurements with radiochromic films that color visibly. This report consists of two documents for use with the RisoeScan software. The User Manual tells how to use the program and the Toolset for Retrospective Validation describes how to perform a retrospective validation of the software. (au)

  9. Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.

    Science.gov (United States)

    Kolokitha, Olga-Elpis

    2007-10-01

    The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.

  10. GPM GROUND VALIDATION ENVIRONMENT CANADA (EC) MANUAL PRECIPITATION MEASUREMENTS GCPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Environment Canada (EC) Manual Precipitation Measurements GCPEx dataset was collected during the GPM Cold-season Precipitation Experiment...

  11. Validation of an educative manual for patients with head and neck cancer submitted to radiation therapy

    Directory of Open Access Journals (Sweden)

    Flávia Oliveira de Almeida Marques da Cruz

    2016-01-01

    Full Text Available Abstract Objective: develop the content and face validation of an educative manual for patients with head and neck cancer submitted to radiation therapy. Method: descriptive methodological research. The Theory of Psychometrics was used for the validation process, developed by 15 experts in the theme area of the educative manual and by two language and publicity professionals. A minimum agreement level of 80% was considered to guarantee the validity of the material. Results: the items addressed in the assessment tool of the educative manual were divided in three blocks: objectives, structure and format, and relevance. Only one item, related to the sociocultural level of the target public, obtained an agreement rate <80%, and was reformulated based on the participants' suggestions. All other items were considered appropriate and/or complete appropriate in the three blocks proposed: objectives - 92.38%, structure and form - 89.74%, and relevance - 94.44%. Conclusion: the face and content validation of the educative manual proposed were attended to. This can contribute to the understanding of the therapeutic process the head and neck cancer patient is submitted to during the radiation therapy, besides supporting clinical practice through the nursing consultation.

  12. Manual patient transfers used most often by student and staff nurses are consistent with their perceptions of transfer training, and performance confidence.

    Science.gov (United States)

    van Wyk, Paula M; Weir, Patricia L; Andrews, David M

    2015-01-01

    A disconnect in manual patient transfer (MPT) training practices for nurses, between what is taught and used in academic and clinical settings, could have implications for injury. This study aimed to determine: 1. what MPTs student and staff nurses use in clinical settings, and 2. if the MPTs used most often were also the ones they perceived that they received training for and had the most confidence performing. Survey responses from student nurses (n=163) (mid-sized university) and staff nurses (n=33) (local hospital) regarding 19 MPTs were analyzed to determine which transfers were perceived to be used most often, and which ones they had received training for and had the greatest confidence performing. The MPTs nurses perceived using most often were the same transfers they had the greatest confidence performing and for which they perceived receiving training. However, these MPTs were not taught at the university at the time of this investigation. Reducing the disconnect between manual patient transfer training obtained in the academic and clinical environments will hopefully reduce the risk of injury for nurses and improve the quality of care for patients.

  13. Validation of an educative manual for patients with head and neck cancer submitted to radiation therapy 1

    Science.gov (United States)

    da Cruz, Flávia Oliveira de Almeida Marques; Ferreira, Elaine Barros; Vasques, Christiane Inocêncio; da Mata, Luciana Regina Ferreira; dos Reis, Paula Elaine Diniz

    2016-01-01

    Abstract Objective: develop the content and face validation of an educative manual for patients with head and neck cancer submitted to radiation therapy. Method: descriptive methodological research. The Theory of Psychometrics was used for the validation process, developed by 15 experts in the theme area of the educative manual and by two language and publicity professionals. A minimum agreement level of 80% was considered to guarantee the validity of the material. Results: the items addressed in the assessment tool of the educative manual were divided in three blocks: objectives, structure and format, and relevance. Only one item, related to the sociocultural level of the target public, obtained an agreement rate manual proposed were attended to. This can contribute to the understanding of the therapeutic process the head and neck cancer patient is submitted to during the radiation therapy, besides supporting clinical practice through the nursing consultation. PMID:27305178

  14. Development and validation of an instrument to measure nurse educator perceived confidence in clinical teaching.

    Science.gov (United States)

    Nguyen, Van N B; Forbes, Helen; Mohebbi, Mohammadreza; Duke, Maxine

    2017-12-01

    Teaching nursing in clinical environments is considered complex and multi-faceted. Little is known about the role of the clinical nurse educator, specifically the challenges related to transition from clinician, or in some cases, from newly-graduated nurse to that of clinical nurse educator, as occurs in developing countries. Confidence in the clinical educator role has been associated with successful transition and the development of role competence. There is currently no valid and reliable instrument to measure clinical nurse educator confidence. This study was conducted to develop and psychometrically test an instrument to measure perceived confidence among clinical nurse educators. A multi-phase, multi-setting survey design was used. A total of 468 surveys were distributed, and 363 were returned. Data were analyzed using exploratory and confirmatory factor analyses. The instrument was successfully tested and modified in phase 1, and factorial validity was subsequently confirmed in phase 2. There was strong evidence of internal consistency, reliability, content, and convergent validity of the Clinical Nurse Educator Skill Acquisition Assessment instrument. The resulting instrument is applicable in similar contexts due to its rigorous development and validation process. © 2017 The Authors. Nursing & Health Sciences published by John Wiley & Sons Australia, Ltd.

  15. Automatic, semi-automatic and manual validation of urban drainage data.

    Science.gov (United States)

    Branisavljević, N; Prodanović, D; Pavlović, D

    2010-01-01

    Advances in sensor technology and the possibility of automated long distance data transmission have made continuous measurements the preferable way of monitoring urban drainage processes. Usually, the collected data have to be processed by an expert in order to detect and mark the wrong data, remove them and replace them with interpolated data. In general, the first step in detecting the wrong, anomaly data is called the data quality assessment or data validation. Data validation consists of three parts: data preparation, validation scores generation and scores interpretation. This paper will present the overall framework for the data quality improvement system, suitable for automatic, semi-automatic or manual operation. The first two steps of the validation process are explained in more detail, using several validation methods on the same set of real-case data from the Belgrade sewer system. The final part of the validation process, which is the scores interpretation, needs to be further investigated on the developed system.

  16. Validation to Portuguese of the Scale of Student Satisfaction and Self-Confidence in Learning.

    Science.gov (United States)

    Almeida, Rodrigo Guimarães dos Santos; Mazzo, Alessandra; Martins, José Carlos Amado; Baptista, Rui Carlos Negrão; Girão, Fernanda Berchelli; Mendes, Isabel Amélia Costa

    2015-01-01

    Translate and validate to Portuguese the Scale of Student Satisfaction and Self-Confidence in Learning. Methodological translation and validation study of a research tool. After following all steps of the translation process, for the validation process, the event III Workshop Brazil - Portugal: Care Delivery to Critical Patients was created, promoted by one Brazilian and another Portuguese teaching institution. 103 nurses participated. As to the validity and reliability of the scale, the correlation pattern between the variables, the sampling adequacy test (Kaiser-Meyer-Olkin) and the sphericity test (Bartlett) showed good results. In the exploratory factorial analysis (Varimax), item 9 behaved better in factor 1 (Satisfaction) than in factor 2 (Self-confidence in learning). The internal consistency (Cronbach's alpha) showed coefficients of 0.86 in factor 1 with six items and 0.77 for factor 2 with 07 items. In Portuguese this tool was called: Escala de Satisfação de Estudantes e Autoconfiança na Aprendizagem. The results found good psychometric properties and a good potential use. The sampling size and specificity are limitations of this study, but future studies will contribute to consolidate the validity of the scale and strengthen its potential use.

  17. Astronaut training manual

    Science.gov (United States)

    Coleman, E. A.

    1980-01-01

    Scientific information from previous space flights, space medicine, exercise physiology, and sports medicine was used to prepare a physical fitness manual suitable for use by members of the NASA astronaut population. A variety of scientifically valid exercise programs and activities suitable for the development of physical fitness are provided. Programs, activities, and supportive scientific data are presented in a concise, easy to read format so as to permit the user to select his or her mode of training with confidence and devote time previously spent experimenting with training routines to preparation for space flight. The programs and activities included were tested and shown to be effective and enjoyable.

  18. Validation to Portuguese of the Scale of Student Satisfaction and Self-Confidence in Learning

    Directory of Open Access Journals (Sweden)

    Rodrigo Guimarães dos Santos Almeida

    2015-12-01

    Full Text Available Objective: translate and validate to Portuguese the Scale of Student Satisfaction and Self-Confidence in Learning. Material and Methods: methodological translation and validation study of a research tool. After following all steps of the translation process, for the validation process, the event III Workshop Brazil - Portugal: Care Delivery to Critical Patients was created, promoted by one Brazilian and another Portuguese teaching institution. Results: 103 nurses participated. As to the validity and reliability of the scale, the correlation pattern between the variables, the sampling adequacy test (Kaiser-Meyer-Olkin and the sphericity test (Bartlett showed good results. In the exploratory factorial analysis (Varimax, item 9 behaved better in factor 1 (Satisfaction than in factor 2 (Self-confidence in learning. The internal consistency (Cronbach's alpha showed coefficients of 0.86 in factor 1 with six items and 0.77 for factor 2 with 07 items. Conclusion: in Portuguese this tool was called: Escala de Satisfação de Estudantes e Autoconfiança na Aprendizagem. The results found good psychometric properties and a good potential use. The sampling size and specificity are limitations of this study, but future studies will contribute to consolidate the validity of the scale and strengthen its potential use.

  19. RisøScan 1.0 - User manual and toolset for retrospective validation

    DEFF Research Database (Denmark)

    Helt-Hansen, Jakob

    2004-01-01

    The RisøScan software is used for dose measurements with radiochromic films that color visibly. This report consists of two documents for use with the RisøScan software. The User Manual tells how to use the program and the Toolset for RetrospectiveValidation describes how to perform a retrospective...

  20. Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy

    OpenAIRE

    Kolokitha, Olga-Elpis

    2007-01-01

    Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manu...

  1. Validation to Portuguese of the Scale of Student Satisfaction and Self-Confidence in Learning1

    Science.gov (United States)

    Almeida, Rodrigo Guimarães dos Santos; Mazzo, Alessandra; Martins, José Carlos Amado; Baptista, Rui Carlos Negrão; Girão, Fernanda Berchelli; Mendes, Isabel Amélia Costa

    2015-01-01

    Objective: translate and validate to Portuguese the Scale of Student Satisfaction and Self-Confidence in Learning. Material and Methods: methodological translation and validation study of a research tool. After following all steps of the translation process, for the validation process, the event III Workshop Brazil - Portugal: Care Delivery to Critical Patients was created, promoted by one Brazilian and another Portuguese teaching institution. Results: 103 nurses participated. As to the validity and reliability of the scale, the correlation pattern between the variables, the sampling adequacy test (Kaiser-Meyer-Olkin) and the sphericity test (Bartlett) showed good results. In the exploratory factorial analysis (Varimax), item 9 behaved better in factor 1 (Satisfaction) than in factor 2 (Self-confidence in learning). The internal consistency (Cronbach's alpha) showed coefficients of 0.86 in factor 1 with six items and 0.77 for factor 2 with 07 items. Conclusion: in Portuguese this tool was called: Escala de Satisfação de Estudantes e Autoconfiança na Aprendizagem. The results found good psychometric properties and a good potential use. The sampling size and specificity are limitations of this study, but future studies will contribute to consolidate the validity of the scale and strengthen its potential use. PMID:26625990

  2. Valid and efficient manual estimates of intracranial volume from magnetic resonance images

    International Nuclear Information System (INIS)

    Klasson, Niklas; Olsson, Erik; Rudemo, Mats; Eckerström, Carl; Malmgren, Helge; Wallin, Anders

    2015-01-01

    Manual segmentations of the whole intracranial vault in high-resolution magnetic resonance images are often regarded as very time-consuming. Therefore it is common to only segment a few linearly spaced intracranial areas to estimate the whole volume. The purpose of the present study was to evaluate how the validity of intracranial volume estimates is affected by the chosen interpolation method, orientation of the intracranial areas and the linear spacing between them. Intracranial volumes were manually segmented on 62 participants from the Gothenburg MCI study using 1.5 T, T 1 -weighted magnetic resonance images. Estimates of the intracranial volumes were then derived using subsamples of linearly spaced coronal, sagittal or transversal intracranial areas from the same volumes. The subsamples of intracranial areas were interpolated into volume estimates by three different interpolation methods. The linear spacing between the intracranial areas ranged from 2 to 50 mm and the validity of the estimates was determined by comparison with the entire intracranial volumes. A progressive decrease in intra-class correlation and an increase in percentage error could be seen with increased linear spacing between intracranial areas. With small linear spacing (≤15 mm), orientation of the intracranial areas and interpolation method had negligible effects on the validity. With larger linear spacing, the best validity was achieved using cubic spline interpolation with either coronal or sagittal intracranial areas. Even at a linear spacing of 50 mm, cubic spline interpolation on either coronal or sagittal intracranial areas had a mean absolute agreement intra-class correlation with the entire intracranial volumes above 0.97. Cubic spline interpolation in combination with linearly spaced sagittal or coronal intracranial areas overall resulted in the most valid and robust estimates of intracranial volume. Using this method, valid ICV estimates could be obtained in less than five

  3. DBCG hypo trial validation of radiotherapy parameters from a national data bank versus manual reporting

    DEFF Research Database (Denmark)

    Brink, Carsten; Lorenzen, Ebbe L; Krogh, Simon Long

    2018-01-01

    of dose information, since the two patients had been treated with an electron boost based on a manual calculation, thus data was not exported to the data bank, and this was not detected prior to comparison with the manual data. For a few database fields in the manual data an ambiguity of the parameter...... definition of the specific field is seen in the data. This was not the case for the data bank, which extract all data consistently. CONCLUSIONS: In terms of data quality the data bank is superior to manually reported values. However, there is a need to allocate resources for checking the validity...... of the available data as well as ensuring that all relevant data is present. The data bank contains more detailed information, and thus facilitates research related to the actual dose distribution in the patients....

  4. The relationship between fundamental movement skill proficiency and physical self-confidence among adolescents.

    Science.gov (United States)

    McGrane, Bronagh; Belton, Sarahjane; Powell, Danielle; Issartel, Johann

    2017-09-01

    This study aims to assess fundamental movement skill (FMS) proficiency, physical self-confidence levels, and the relationship between these variables and gender differences among adolescents. Three hundred and ninety five adolescents aged 13.78 years (SD = ±1.2) from 20 schools were involved in this study. The Test of Gross Motor Development-2nd Edition (TGMD), TGMD-2 and Victorian Skills Manual were used to assess 15 FMS. Participants' physical self-confidence was also assessed using a valid skill-specific scale. A significant correlation was observed between FMS proficiency and physical self-confidence for females only (r = 0.305, P < 0.001). Males rated themselves as having significantly higher physical self-confidence levels than females (P = 0.001). Males scored significantly higher than females in FMS proficiency (P < 0.05), and the lowest physical self-confidence group were significantly less proficient at FMS than the medium (P < 0.001) and high physical self-confidence groups (P < 0.05). This information not only highlights those in need of assistance to develop their FMS but will also facilitate in the development of an intervention which aims to improve physical self-confidence and FMS proficiency.

  5. Validation of an educative manual for patients with head and neck cancer submitted to radiation therapy.

    Science.gov (United States)

    Cruz, Flávia Oliveira de Almeida Marques da; Ferreira, Elaine Barros; Vasques, Christiane Inocêncio; Mata, Luciana Regina Ferreira da; Reis, Paula Elaine Diniz Dos

    2016-06-14

    develop the content and face validation of an educative manual for patients with head and neck cancer submitted to radiation therapy. descriptive methodological research. The Theory of Psychometrics was used for the validation process, developed by 15 experts in the theme area of the educative manual and by two language and publicity professionals. A minimum agreement level of 80% was considered to guarantee the validity of the material. the items addressed in the assessment tool of the educative manual were divided in three blocks: objectives, structure and format, and relevance. Only one item, related to the sociocultural level of the target public, obtained an agreement rate publicidade. Foi considerado o índice de concordância de, no mínimo, 80% para se garantir a validação do material. os itens abordados no instrumento de avaliação do manual educativo foram divididos em três blocos: objetivos, estrutura e apresentação, e relevância. Apenas um item, relacionado ao nível sociocultural do público-alvo, obteve índice de concordância publicidad. Fue considerado un índice de concordancia que fuese, por lo menos, de 80%, para garantizar la validación del material. los ítems abordados en el instrumento de evaluación del manual educativo fueron divididos en tres bloques: objetivos, estructura y presentación, y relevancia. Apenas un ítem, relacionado al nivel sociocultural del público-objetivo, obtuvo un índice de concordancia <80%, habiendo sido reformulado con base en las sugestiones de los participantes. Todos los otros ítems fueron considerados adecuados y/o totalmente adecuados en los tres bloques propuestos: objetivos (92,38%), estructura y presentación (89,74%), y relevancia (94,44%). el manual educativo propuesto fue considerado válido en lo que se refiere al contenido y a la apariencia. Se sugiere que puede contribuir para la comprensión del proceso terapéutico, al cual el paciente con cáncer de cabeza y cuello es sometido al

  6. Targeting Low Career Confidence Using the Career Planning Confidence Scale

    Science.gov (United States)

    McAuliffe, Garrett; Jurgens, Jill C.; Pickering, Worth; Calliotte, James; Macera, Anthony; Zerwas, Steven

    2006-01-01

    The authors describe the development and validation of a test of career planning confidence that makes possible the targeting of specific problem issues in employment counseling. The scale, developed using a rational process and the authors' experience with clients, was tested for criterion-related validity against 2 other measures. The scale…

  7. Validation of self - confidence scale for clean urinary intermittent self - catheterization for patients and health - caregivers

    Directory of Open Access Journals (Sweden)

    Cintia Fernandes Baccarin Biaziolo

    Full Text Available ABSTRACT Objective To validate a measurement instrument for clean intermittent self-catheterization for patients and health-caregivers. Material and Methods Methodological study of instrument validation performed at a Rehabilitation Center in a University hospital for patients submitted to clean intermittent self-catheterization and their health-caregivers. Following ethical criteria, data were collected during interview with nurse staff using a Likert question form containing 16 items with 5 points each: “no confidence”=1, “little confidence”=2, “confident”=3, “very confident”=4 and “completely confident”=5. Questionnaire called “Self-Confident Scale for Clean Intermittent Self-catheterization” (SCSCISC was constructed based on literature and previously validated (appearance and content. Results The instrument was validated by 122 patients and 119 health-caregivers, in a proportion of 15:1. It was observed a good linear association and sample adequacy KMO 0.931 and X2=2881.63, p<0.001. Anti-image matrix showed high values at diagonal suggesting inclusion of all factors. Screen plot analysis showed a suggestion of items maintenance in a single set. It was observed high correlation of all items with the total, alpha-Cronbach 0.944. The same results were obtained in subsamples of patients and health-caregivers. Conclusion The instrument showed good psychometric adequacy corroborating its use for evaluation of self-confidence during clean intermittent self-catheterization.

  8. DBCG hypo trial validation of radiotherapy parameters from a national data bank versus manual reporting.

    Science.gov (United States)

    Brink, Carsten; Lorenzen, Ebbe L; Krogh, Simon Long; Westberg, Jonas; Berg, Martin; Jensen, Ingelise; Thomsen, Mette Skovhus; Yates, Esben Svitzer; Offersen, Birgitte Vrou

    2018-01-01

    The current study evaluates the data quality achievable using a national data bank for reporting radiotherapy parameters relative to the classical manual reporting method of selected parameters. The data comparison is based on 1522 Danish patients of the DBCG hypo trial with data stored in the Danish national radiotherapy data bank. In line with standard DBCG trial practice selected parameters were also reported manually to the DBCG database. Categorical variables are compared using contingency tables, and comparison of continuous parameters is presented in scatter plots. For categorical variables 25 differences between the data bank and manual values were located. Of these 23 were related to mistakes in the manual reported value whilst the remaining two were a wrong classification in the data bank. The wrong classification in the data bank was related to lack of dose information, since the two patients had been treated with an electron boost based on a manual calculation, thus data was not exported to the data bank, and this was not detected prior to comparison with the manual data. For a few database fields in the manual data an ambiguity of the parameter definition of the specific field is seen in the data. This was not the case for the data bank, which extract all data consistently. In terms of data quality the data bank is superior to manually reported values. However, there is a need to allocate resources for checking the validity of the available data as well as ensuring that all relevant data is present. The data bank contains more detailed information, and thus facilitates research related to the actual dose distribution in the patients.

  9. Comparison of 3D laser-based photonic scans and manual anthropometric measurements of body size and shape in a validation study of 123 young Swiss men

    Directory of Open Access Journals (Sweden)

    Nikola Koepke

    2017-02-01

    Full Text Available Background Manual anthropometric measurements are time-consuming and challenging to perform within acceptable intra- and inter-individual error margins in large studies. Three-dimensional (3D laser body scanners provide a fast and precise alternative: within a few seconds the system produces a 3D image of the body topography and calculates some 150 standardised body size measurements. Objective The aim was to enhance the small number of existing validation studies and compare scan and manual techniques based on five selected measurements. We assessed the agreement between two repeated measurements within the two methods, analysed the direct agreement between the two methods, and explored the differences between the techniques when used in regressions assessing the effect of health related determinants on body shape indices. Methods We performed two repeated body scans on 123 volunteering young men using a Vitus Smart XXL body scanner. We manually measured height, waist, hip, buttock, and chest circumferences twice for each participant according to the WHO guidelines. The participants also filled in a basic questionnaire. Results Mean differences between the two scan measurements were smaller than between the two manual measurements, and precision as well as intra-class correlation coefficients were higher. Both techniques were strongly correlated. When comparing means between both techniques we found significant differences: Height was systematically shorter by 2.1 cm, whereas waist, hip and bust circumference measurements were larger in the scans by 1.17–4.37 cm. In consequence, body shape indices also became larger and the prevalence of overweight was greater when calculated from the scans. Between 4.1% and 7.3% of the probands changed risk category from normal to overweight when classified based on the scans. However, when employing regression analyses the two measurement techniques resulted in very similar coefficients, confidence

  10. An introduction to use of the USACE HTRW program's data validation guidelines engineering manual

    International Nuclear Information System (INIS)

    Becker, L.D.; Coats, K.H.

    1994-01-01

    Data validation has been defined by regulatory agencies as a systematic process (consisting of data editing, screening, checking, auditing, verification, certification, and review) for comparing data to established criteria in order to provide assurance that data are adequate for their intended use. A problem for the USACE HTRW Program was that clearly defined data validation guidelines were available only for analytical data quality level IV. These functional data validation guidelines were designed for validation of data produced using protocols from the US E.P.A.'s Contract Laboratory Program (CLP). Unfortunately, USACE experience demonstrates that these level IV functional data validation guidelines were being used to validate data not produced under the CLP. The resulting data validation product was less than satisfactory for USACE HTRW needs. Therefore, the HTRW-MCX initiated an Engineering Manual (EM) for validation of analytical data quality levels other than IV. This EM is entitle ''USACE HTRW Data Validation Guidelines.'' Use of the EM is required for validation of analytical data relating to projects under the jurisdiction of the Department of the Army, Corps of Engineers, Hazardous, Toxic, and Radioactive Waste Program. These data validation guidelines include procedures and checklists for technical review of analytical data at quality levels I, II, III, and V

  11. Validation of an instrument to assess evidence-based practice knowledge, attitudes, access, and confidence in the dental environment.

    Science.gov (United States)

    Hendricson, William D; Rugh, John D; Hatch, John P; Stark, Debra L; Deahl, Thomas; Wallmann, Elizabeth R

    2011-02-01

    This article reports the validation of an assessment instrument designed to measure the outcomes of training in evidence-based practice (EBP) in the context of dentistry. Four EBP dimensions are measured by this instrument: 1) understanding of EBP concepts, 2) attitudes about EBP, 3) evidence-accessing methods, and 4) confidence in critical appraisal. The instrument-the Knowledge, Attitudes, Access, and Confidence Evaluation (KACE)-has four scales, with a total of thirty-five items: EBP knowledge (ten items), EBP attitudes (ten), accessing evidence (nine), and confidence (six). Four elements of validity were assessed: consistency of items within the KACE scales (extent to which items within a scale measure the same dimension), discrimination (capacity to detect differences between individuals with different training or experience), responsiveness (capacity to detect the effects of education on trainees), and test-retest reliability. Internal consistency of scales was assessed by analyzing responses of second-year dental students, dental residents, and dental faculty members using Cronbach coefficient alpha, a statistical measure of reliability. Discriminative validity was assessed by comparing KACE scores for the three groups. Responsiveness was assessed by comparing pre- and post-training responses for dental students and residents. To measure test-retest reliability, the full KACE was completed twice by a class of freshman dental students seventeen days apart, and the knowledge scale was completed twice by sixteen faculty members fourteen days apart. Item-to-scale consistency ranged from 0.21 to 0.78 for knowledge, 0.57 to 0.83 for attitude, 0.70 to 0.84 for accessing evidence, and 0.87 to 0.94 for confidence. For discrimination, ANOVA and post hoc testing by the Tukey-Kramer method revealed significant score differences among students, residents, and faculty members consistent with education and experience levels. For responsiveness to training, dental students

  12. On-line confidence monitoring during decision making.

    Science.gov (United States)

    Dotan, Dror; Meyniel, Florent; Dehaene, Stanislas

    2018-02-01

    Humans can readily assess their degree of confidence in their decisions. Two models of confidence computation have been proposed: post hoc computation using post-decision variables and heuristics, versus online computation using continuous assessment of evidence throughout the decision-making process. Here, we arbitrate between these theories by continuously monitoring finger movements during a manual sequential decision-making task. Analysis of finger kinematics indicated that subjects kept separate online records of evidence and confidence: finger deviation continuously reflected the ongoing accumulation of evidence, whereas finger speed continuously reflected the momentary degree of confidence. Furthermore, end-of-trial finger speed predicted the post-decisional subjective confidence rating. These data indicate that confidence is computed on-line, throughout the decision process. Speed-confidence correlations were previously interpreted as a post-decision heuristics, whereby slow decisions decrease subjective confidence, but our results suggest an adaptive mechanism that involves the opposite causality: by slowing down when unconfident, participants gain time to improve their decisions. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. CTF Validation and Verification Manual

    Energy Technology Data Exchange (ETDEWEB)

    Salko, Robert K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Blyth, Taylor S. [Pennsylvania State Univ., University Park, PA (United States); Dances, Christopher A. [Pennsylvania State Univ., University Park, PA (United States); Magedanz, Jeffrey W. [Pennsylvania State Univ., University Park, PA (United States); Jernigan, Caleb [Holtec International, Marlton, NJ (United States); Kelly, Joeseph [U.S. Nuclear Regulatory Commission (NRC), Rockville, MD (United States); Toptan, Aysenur [North Carolina State Univ., Raleigh, NC (United States); Gergar, Marcus [Pennsylvania State Univ., University Park, PA (United States); Gosdin, Chris [Pennsylvania State Univ., University Park, PA (United States); Avramova, Maria [Pennsylvania State Univ., University Park, PA (United States); Palmtag, Scott [Core Physics, Inc., Cary, NC (United States); Gehin, Jess C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-05-25

    Coolant-Boiling in Rod Arrays- Two Fluids (COBRA-TF) is a Thermal/Hydraulic (T/H) simulation code designed for Light Water Reactor (LWR) analysis. It uses a two-fluid, three-field (i.e. fluid film, fluid drops, and vapor) modeling approach. Both sub-channel and 3D Cartesian forms of nine conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and has been used and modified by several institutions over the last several decades. COBRA-TF is also used at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Management Group (RDFMG), and has been improved, updated, and subsequently became the PSU RDFMG version of COBRA-TF (CTF). One part of the improvement process includes validating the methods in CTF. This document seeks to provide a certain level of certainty and confidence in the predictive capabilities of the code for the scenarios it was designed to model--rod bundle geometries with operating conditions that are representative of prototypical Pressurized Water Reactor (PWR)s and Boiling Water Reactor (BWR)s in both normal and accident conditions. This is done by modeling a variety of experiments that simulate these scenarios and then presenting a qualitative and quantitative analysis of the results that demonstrates the accuracy to which CTF is capable of capturing specific quantities of interest.

  14. Reliability and validity of food portion size estimation from images using manual flexible digital virtual meshes

    Science.gov (United States)

    The eButton takes frontal images at 4 second intervals throughout the day. A three-dimensional (3D) manually administered wire mesh procedure has been developed to quantify portion sizes from the two-dimensional (2D) images. This paper reports a test of the interrater reliability and validity of use...

  15. Test re-test reliability and construct validity of the star-track test of manual dexterity

    DEFF Research Database (Denmark)

    Kildebro, Niels; Amirian, Ilda; Gögenur, Ismail

    2015-01-01

    Objectives. We wished to determine test re-test reliability and construct validity of the star-track test of manual dexterity. Design. Test re-test reliability was examined in a controlled study. Construct validity was tested in a blinded randomized crossover study. Setting. The study was performed...... at a university hospital in Denmark. Participants. A total of 11 subjects for test re-test and 20 subjects for the construct validity study were included. All subjects were healthy volunteers. Intervention. The test re-test trial had two measurements with 2 days pause in between. The interventions...... in the construct validity study included baseline measurement, intervention 1: fatigue, intervention 2: stress, and intervention 3: fatigue and stress. There was a 2 day pause between each intervention. Main outcome measure. An integrated measure of completion time and number of errors was used. Results. All...

  16. JacketSE: An Offshore Wind Turbine Jacket Sizing Tool; Theory Manual and Sample Usage with Preliminary Validation

    Energy Technology Data Exchange (ETDEWEB)

    Damiani, Rick [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-02-08

    This manual summarizes the theory and preliminary verifications of the JacketSE module, which is an offshore jacket sizing tool that is part of the Wind-Plant Integrated System Design & Engineering Model toolbox. JacketSE is based on a finite-element formulation and on user-prescribed inputs and design standards' criteria (constraints). The physics are highly simplified, with a primary focus on satisfying ultimate limit states and modal performance requirements. Preliminary validation work included comparing industry data and verification against ANSYS, a commercial finite-element analysis package. The results are encouraging, and future improvements to the code are recommended in this manual.

  17. An Introduction to Confidence Intervals for Both Statistical Estimates and Effect Sizes.

    Science.gov (United States)

    Capraro, Mary Margaret

    This paper summarizes methods of estimating confidence intervals, including classical intervals and intervals for effect sizes. The recent American Psychological Association (APA) Task Force on Statistical Inference report suggested that confidence intervals should always be reported, and the fifth edition of the APA "Publication Manual"…

  18. User's Manual for Data for Validating Models for PV Module Performance

    Energy Technology Data Exchange (ETDEWEB)

    Marion, W.; Anderberg, A.; Deline, C.; Glick, S.; Muller, M.; Perrin, G.; Rodriguez, J.; Rummel, S.; Terwilliger, K.; Silverman, T. J.

    2014-04-01

    This user's manual describes performance data measured for flat-plate photovoltaic (PV) modules installed in Cocoa, Florida, Eugene, Oregon, and Golden, Colorado. The data include PV module current-voltage curves and associated meteorological data for approximately one-year periods. These publicly available data are intended to facilitate the validation of existing models for predicting the performance of PV modules, and for the development of new and improved models. For comparing different modeling approaches, using these public data will provide transparency and more meaningful comparisons of the relative benefits.

  19. Technical Manual: 2002 Series GED Tests

    Science.gov (United States)

    Ezzelle, Carol; Setzer, J. Carl

    2009-01-01

    This manual was written to provide technical information regarding the 2002 Series GED (General Educational Development) Tests. Throughout this manual, documentation is provided regarding the development of the GED Tests, data collection activities, as well as reliability and validity evidence. The purpose of this manual is to provide evidence…

  20. The reliability and validity of three questionnaires: The Student Satisfaction and Self-Confidence in Learning Scale, Simulation Design Scale, and Educational Practices Questionnaire.

    Science.gov (United States)

    Unver, Vesile; Basak, Tulay; Watts, Penni; Gaioso, Vanessa; Moss, Jacqueline; Tastan, Sevinc; Iyigun, Emine; Tosun, Nuran

    2017-02-01

    The purpose of this study was to adapt the "Student Satisfaction and Self-Confidence in Learning Scale" (SCLS), "Simulation Design Scale" (SDS), and "Educational Practices Questionnaire" (EPQ) developed by Jeffries and Rizzolo into Turkish and establish the reliability and the validity of these translated scales. A sample of 87 nursing students participated in this study. These scales were cross-culturally adapted through a process including translation, comparison with original version, back translation, and pretesting. Construct validity was evaluated by factor analysis, and criterion validity was evaluated using the Perceived Learning Scale, Patient Intervention Self-confidence/Competency Scale, and Educational Belief Scale. Cronbach's alpha values were found as 0.77-0.85 for SCLS, 0.73-0.86 for SDS, and 0.61-0.86 for EPQ. The results of this study show that the Turkish versions of all scales are validated and reliable measurement tools.

  1. Understanding Confidence Intervals With Visual Representations

    OpenAIRE

    Navruz, Bilgin; Delen, Erhan

    2014-01-01

    In the present paper, we showed how confidence intervals (CIs) are valuable and useful in research studies when they are used in the correct form with correct interpretations. The sixth edition of the APA (2010) Publication Manual strongly recommended reporting CIs in research studies, and it was described as “the best reporting strategy” (p. 34). Misconceptions and correct interpretations of CIs were presented from several textbooks. In addition, limitations of the null hypothesis statistica...

  2. The minimal manual: is less really more?

    NARCIS (Netherlands)

    Lazonder, Adrianus W.; van der Meij, Hans

    1993-01-01

    Carroll, Smith-Kerker, Ford and Mazur-Rimetz (The minimal manual, Human-Computer Interaction , 3, 123-153, 1987) have introduced the minimal manual as an alternative to standard self-instruction manuals. While their research indicates strong gains, only a few attempts have been made to validate

  3. Step-by-Step Visual Manuals: Design and Development

    Science.gov (United States)

    Urata, Toshiyuki

    2004-01-01

    The types of handouts and manuals that are used in technology training vary. Some describe procedures in a narrative way without graphics; some employ step-by-step instructions with screen captures. According to Thirlway (1994), a training manual should be like a tutor that permits a student to learn at his own pace and gives him confidence for…

  4. Semi-automating the manual literature search for systematic reviews increases efficiency.

    Science.gov (United States)

    Chapman, Andrea L; Morgan, Laura C; Gartlehner, Gerald

    2010-03-01

    To minimise retrieval bias, manual literature searches are a key part of the search process of any systematic review. Considering the need to have accurate information, valid results of the manual literature search are essential to ensure scientific standards; likewise efficient approaches that minimise the amount of personnel time required to conduct a manual literature search are of great interest. The objective of this project was to determine the validity and efficiency of a new manual search method that utilises the scopus database. We used the traditional manual search approach as the gold standard to determine the validity and efficiency of the proposed scopus method. Outcome measures included completeness of article detection and personnel time involved. Using both methods independently, we compared the results based on accuracy of the results, validity and time spent conducting the search, efficiency. Regarding accuracy, the scopus method identified the same studies as the traditional approach indicating its validity. In terms of efficiency, using scopus led to a time saving of 62.5% compared with the traditional approach (3 h versus 8 h). The scopus method can significantly improve the efficiency of manual searches and thus of systematic reviews.

  5. The short version of the Activities-specific Balance Confidence (ABC) scale: its validity, reliability, and relationship to balance impairment and falls in older adults.

    Science.gov (United States)

    Schepens, Stacey; Goldberg, Allon; Wallace, Melissa

    2010-01-01

    A shortened version of the ABC 16-item scale (ABC-16), the ABC-6, has been proposed as an alternative balance confidence measure. We investigated whether the ABC-6 is a valid and reliable measure of balance confidence and examined its relationship to balance impairment and falls in older adults. Thirty-five community-dwelling older adults completed the ABC-16, including the 6 questions of the ABC-6. They also completed the following clinical balance tests: unipedal stance time (UST), functional reach (FR), Timed Up and Go (TUG), and maximum step length (MSL). Participants reported 12-month falls history. Balance confidence on the ABC-6 was significantly lower than on the ABC-16, however scores were highly correlated. Fallers reported lower balance confidence than non-fallers as measured by the ABC-6 scale, but confidence did not differ between the groups with the ABC-16. The ABC-6 significantly correlated with all balance tests assessed and number of falls. The ABC-16 significantly correlated with all balance tests assessed, but not with number of falls. Test-retest reliability for the ABC-16 and ABC-6 was good to excellent. The ABC-6 is a valid and reliable measure of balance confidence in community-dwelling older adults, and shows stronger relationships to falls than does the ABC-16. The ABC-6 may be a more useful balance confidence assessment tool than the ABC-16. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  6. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques.

    Science.gov (United States)

    Engesæter, Ingvild Øvstebø; Laborie, Lene Bjerke; Lehmann, Trude Gundersen; Sera, Francesco; Fevang, Jonas; Pedersen, Douglas; Morcuende, José; Lie, Stein Atle; Engesæter, Lars Birger; Rosendahl, Karen

    2012-07-01

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Tönnis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good.

  7. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Engesaeter, Ingvild Oevsteboe [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Haukeland University Hospital, The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Bergen (Norway); Laborie, Lene Bjerke; Rosendahl, Karen [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Lehmann, Trude Gundersen; Fevang, Jonas; Engesaeter, Lars Birger [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Sera, Francesco [University College London Institute of Child Health, Medical Research Council Centre of Epidemiology for Child Health, London (United Kingdom); Pedersen, Douglas; Morcuende, Jose [University of Iowa Hospital and Clinics, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States); Lie, Stein Atle [Uni Health, Uni Research, Bergen (Norway)

    2012-07-15

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Toennis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good. (orig.)

  8. Validity of the Prescriber Information in the Danish National Prescription Registry

    DEFF Research Database (Denmark)

    Rasmussen, Lotte; Valentin, Julie; Gesser, Katarina Margareta

    2016-01-01

    The aim of this study was to measure the validity of the prescriber information recorded in the Danish National Prescription Registry (DNPR). The prescriber information recorded in the pharmacies' electronic dispensing system was considered to represent the prescriber information recorded...... in the DNPR. Further, the problem of validity of the prescriber information pertains only to non-electronic prescriptions, as these are manually entered into the dispensing system. The recorded prescriber information was thus validated against information from a total of 2,000 non-electronic prescriptions...... at five Danish community pharmacies. The validity of the recorded prescriber information was measured at the level of the individual prescriber and the prescriber type, respectively. The proportion of non-electronic prescriptions with incorrect registrations was 22.4% (95% Confidence Interval (CI): 20...

  9. Validity of the Mexican version of the combined Foot Care Confidence / Foot-Care Behavior scale for diabetes

    Directory of Open Access Journals (Sweden)

    Jaime A. García-Inzunza

    2015-07-01

    Full Text Available OBJECTIVE: To 1 translate / transculturally adapt the original (English-language combined Foot Care Confidence Scale / Foot-Care Behavior instrument (FCCS-FCB to produce a Mexican-Spanish version and 2 determine its validity and reliability in a population with diabetes in Tijuana, Mexico. METHODS: The original FCCS-FCB was translated (and back-translated, the content validated (by a group of health professional experts, and the instrument applied to 304 patients 23-78 years old in diabetes support groups in Tijuana, Mexico. Internal consistency for the study constructs ("self-efficacy," and risk / preventive foot self-care behaviors was measured using Cronbach's alpha. The constructs were validated using principal component factor analysis. RESULTS: The Cronbach's alpha values for internal consistency were 0.782 for self-efficacy and 0.505 for behaviors. Based on the analysis, two factors explained 49.1% of the total variance for self-efficacy, and six factors explained 57.7% of the total variance for behaviors. The results were consistent with those for the original (English version of the FCCS-FCB. CONCLUSIONS: The Mexican version of the FCCS-FCB is a reliable and valid instrument recommended for use with Mexican-Spanish-speaking patients with diabetes.

  10. Operator's manual actions in case of fire; Acciones manuales del operador en caso de incendio

    Energy Technology Data Exchange (ETDEWEB)

    Saez de Tejada Madina, P.; Perez Lobo, E. M.; Velasco Ramirez, R.; Velasco Ramirez, R.; Fernandez Ramos, P.

    2012-07-01

    Vandellos II, following the guidelines GS 01.19 of CSN and RG 1.189 rev. 2, has identified the need to consider a number of local manual actions to be performed by the staff of shift operation and need to be validated according NUREG 1852. The local manual actions include corrective and preventive actions, such as local start and shooting of bombs, checking positions ... According NUREG-1852 these actions must be validated with conditions as similar as possible to those expected, in conjunction with the operating of Vandellos II.

  11. Salinas : theory manual.

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Timothy Francis; Reese, Garth M.; Bhardwaj, Manoj Kumar

    2011-11-01

    Salinas provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Salinas. For a more detailed description of how to use Salinas, we refer the reader to Salinas, User's Notes. Many of the constructs in Salinas are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Salinas are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer notes manual, the user's notes and of course the material in the open literature.

  12. A predeployment trauma team training course creates confidence in teamwork and clinical skills: a post-Afghanistan deployment validation study of Canadian Forces healthcare personnel.

    Science.gov (United States)

    McLaughlin, Thomas; Hennecke, Peter; Garraway, Naisan Robert; Evans, David C; Hameed, Morad; Simons, Richard K; Doucet, Jay; Hansen, Daniel; Annand, Siobhan; Bell, Nathaniel; Brown, D Ross

    2011-11-01

    The 10-day Intensive Trauma Team Training Course (ITTTC) was developed by the Canadian Forces (CFs) to teach teamwork and clinical trauma skills to military healthcare personnel before deploying to Afghanistan. This article attempts to validate the impact of the ITTTC by surveying participants postdeployment. A survey consisting of Likert-type multiple-choice questions was created and sent to all previous ITTTC participants. The survey asked respondents to rate their confidence in applying teamwork skills and clinical skills learned in the ITTTC. It explored the relevancy of objectives and participants' prior familiarity with the objectives. The impact of different training modalities was also surveyed. The survey showed that on average 84.29% of participants were "confident" or "very confident" in applying teamwork skills to their subsequent clinical experience and 52.10% were "confident" or "very confident" in applying clinical knowledge and skills. On average 43.74% of participants were "familiar" or "very familiar" with the clinical topics before the course, indicating the importance of training these skills. Participants found that clinical shadowing was significantly less valuable in training clinical skills than either animal laboratory experience or experience in human patient simulators; 68.57% respondents thought that ITTTC was "important" or "very important" in their training. The ITTTC created lasting self-reported confidence in CFs healthcare personnel surveyed upon return from Afghanistan. This validates the importance of the course for the training of CFs healthcare personnel and supports the value of team training in other areas of trauma and medicine.

  13. Oregon School Bond Manual. Fourth Edition.

    Science.gov (United States)

    Oregon State Dept. of Education, Salem.

    The manual is intended to guide attorneys and officials of school districts in the issuance and sale of school district bonds. Purchasers of school district bonds rely on the recommendations of accredited bond attorneys who render opinions concerning the validity and legality of bond issues offered for sale. This manual is designed to assist in…

  14. Development and validation of a food photography manual, as a tool for estimation of food portion size in epidemiological dietary surveys in Tunisia

    Directory of Open Access Journals (Sweden)

    Mongia Bouchoucha

    2016-08-01

    Full Text Available Background: Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. Methods: A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos to the reference method [food weighing (FW]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland–Altman limits of agreement. In total, 31 male and female volunteers aged 9–89 participated in the study. Results: We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method to those actually consumed (using FW. Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05 and dairy products (p<0.05. The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001 and dietary fiber (p<0.05. A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. Conclusion: The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys.

  15. Development and validation of a food photography manual, as a tool for estimation of food portion size in epidemiological dietary surveys in Tunisia.

    Science.gov (United States)

    Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir

    2016-01-01

    Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland-Altman limits of agreement. In total, 31 male and female volunteers aged 9-89 participated in the study. We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys.

  16. Current Developments in Measuring Academic Behavioural Confidence

    Science.gov (United States)

    Sander, Paul

    2009-01-01

    Using published findings and by further analyses of existing data, the structure, validity and utility of the Academic Behavioural Confidence scale (ABC) is critically considered. Validity is primarily assessed through the scale's relationship with other existing scales as well as by looking for predicted differences. The utility of the ABC scale…

  17. Bigfoot Field Manual, Version 2.1

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.L.; Burrows, S.; Gower, S.T.; Cohen, W.B.

    1999-09-01

    The BigFoot Project is funded by the Earth Science Enterprise to collect and organize data to be used in the National Aeronautics and Space Administration's Earth Observing System (EOS) Validation Program. The data collected by the BigFoot Project are unique in being ground-based observations coincident with satellite overpasses. In addition to collecting data, the BigFoot project will develop and test new algorithms for scaling point measurements to the same spatial scales as the EOS satellite products. This BigFoot Field Manual will be used to achieve completeness and consistency of data collected at four initial BigFoot sites and at future sites that may collect similar validation data. Therefore, validation datasets submitted to the Oak Ridge National Laboratory Distributed Active Archive Center that have been compiled in a manner consistent with the field manual will be especially valuable in the validation program.

  18. Automated quantification of optic nerve axons in primate glaucomatous and normal eyes--method and comparison to semi-automated manual quantification.

    Science.gov (United States)

    Reynaud, Juan; Cull, Grant; Wang, Lin; Fortune, Brad; Gardiner, Stuart; Burgoyne, Claude F; Cioffi, George A

    2012-05-01

    To describe an algorithm and software application (APP) for 100% optic nerve axon counting and to compare its performance with a semi-automated manual (SAM) method in optic nerve cross-section images (images) from normal and experimental glaucoma (EG) nonhuman primate (NHP) eyes. ON cross sections from eight EG eyes from eight NHPs, five EG and five normal eyes from five NHPs, and 12 normal eyes from 12 NHPs were imaged at 100×. Calibration (n = 500) and validation (n = 50) image sets ranging from normal to end-stage damage were assembled. Correlation between APP and SAM axon counts was assessed by Deming regression within the calibration set and a compensation formula was generated to account for the subtle, systematic differences. Then, compensated APP counts for each validation image were compared with the mean and 95% confidence interval of five SAM counts of the validation set performed by a single observer. Calibration set APP counts linearly correlated to SAM counts (APP = 10.77 + 1.03 [SAM]; R(2) = 0.94, P < 0.0001) in normal to end-stage damage images. In the validation set, compensated APP counts fell within the 95% confidence interval of the SAM counts in 42 of the 50 images and were within 12 axons of the confidence intervals in six of the eight remaining images. Uncompensated axon density maps for the normal and EG eyes of a representative NHP were generated. An APP for 100% ON axon counts has been calibrated and validated relative to SAM counts in normal and EG NHP eyes.

  19. Automated Quantification of Optic Nerve Axons in Primate Glaucomatous and Normal Eyes—Method and Comparison to Semi-Automated Manual Quantification

    Science.gov (United States)

    Reynaud, Juan; Cull, Grant; Wang, Lin; Fortune, Brad; Gardiner, Stuart; Burgoyne, Claude F; Cioffi, George A

    2012-01-01

    Purpose. To describe an algorithm and software application (APP) for 100% optic nerve axon counting and to compare its performance with a semi-automated manual (SAM) method in optic nerve cross-section images (images) from normal and experimental glaucoma (EG) nonhuman primate (NHP) eyes. Methods. ON cross sections from eight EG eyes from eight NHPs, five EG and five normal eyes from five NHPs, and 12 normal eyes from 12 NHPs were imaged at 100×. Calibration (n = 500) and validation (n = 50) image sets ranging from normal to end-stage damage were assembled. Correlation between APP and SAM axon counts was assessed by Deming regression within the calibration set and a compensation formula was generated to account for the subtle, systematic differences. Then, compensated APP counts for each validation image were compared with the mean and 95% confidence interval of five SAM counts of the validation set performed by a single observer. Results. Calibration set APP counts linearly correlated to SAM counts (APP = 10.77 + 1.03 [SAM]; R2 = 0.94, P < 0.0001) in normal to end-stage damage images. In the validation set, compensated APP counts fell within the 95% confidence interval of the SAM counts in 42 of the 50 images and were within 12 axons of the confidence intervals in six of the eight remaining images. Uncompensated axon density maps for the normal and EG eyes of a representative NHP were generated. Conclusions. An APP for 100% ON axon counts has been calibrated and validated relative to SAM counts in normal and EG NHP eyes. PMID:22467571

  20. Validating New Software for Semiautomated Liver Volumetry--Better than Manual Measurement?

    Science.gov (United States)

    Noschinski, L E; Maiwald, B; Voigt, P; Wiltberger, G; Kahn, T; Stumpp, P

    2015-09-01

    This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33% vs. 57%, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04 min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience. Both tested types of software allow exact volumetry of resected liver parts. Preoperative prediction can be performed more accurately with the semiautomated software. The semiautomated software is nearly four times faster than the

  1. Manual versus automated coding of free-text self-reported medication data in the 45 and Up Study: a validation study.

    Science.gov (United States)

    Gnjidic, Danijela; Pearson, Sallie-Anne; Hilmer, Sarah N; Basilakis, Jim; Schaffer, Andrea L; Blyth, Fiona M; Banks, Emily

    2015-03-30

    Increasingly, automated methods are being used to code free-text medication data, but evidence on the validity of these methods is limited. To examine the accuracy of automated coding of previously keyed in free-text medication data compared with manual coding of original handwritten free-text responses (the 'gold standard'). A random sample of 500 participants (475 with and 25 without medication data in the free-text box) enrolled in the 45 and Up Study was selected. Manual coding involved medication experts keying in free-text responses and coding using Anatomical Therapeutic Chemical (ATC) codes (i.e. chemical substance 7-digit level; chemical subgroup 5-digit; pharmacological subgroup 4-digit; therapeutic subgroup 3-digit). Using keyed-in free-text responses entered by non-experts, the automated approach coded entries using the Australian Medicines Terminology database and assigned corresponding ATC codes. Based on manual coding, 1377 free-text entries were recorded and, of these, 1282 medications were coded to ATCs manually. The sensitivity of automated coding compared with manual coding was 79% (n = 1014) for entries coded at the exact ATC level, and 81.6% (n = 1046), 83.0% (n = 1064) and 83.8% (n = 1074) at the 5, 4 and 3-digit ATC levels, respectively. The sensitivity of automated coding for blank responses was 100% compared with manual coding. Sensitivity of automated coding was highest for prescription medications and lowest for vitamins and supplements, compared with the manual approach. Positive predictive values for automated coding were above 95% for 34 of the 38 individual prescription medications examined. Automated coding for free-text prescription medication data shows very high to excellent sensitivity and positive predictive values, indicating that automated methods can potentially be useful for large-scale, medication-related research.

  2. Validating new software for semiautomated liver volumetry. Better than manual measurement?

    Energy Technology Data Exchange (ETDEWEB)

    Noschinski, L.E.; Maiwald, B.; Voigt, P.; Kahn, T.; Stumpp, P. [University Hospital Leipzig (Germany). Dept. of Diagnostic and Interventional Radiology; Wiltberger, G. [University Hospital Leipzig (Germany). Dept. of Visceral, Transplantation, Thoracic and Vascular Surgery

    2015-09-15

    This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33 % vs. 57 %, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience.

  3. Validating new software for semiautomated liver volumetry. Better than manual measurement?

    International Nuclear Information System (INIS)

    Noschinski, L.E.; Maiwald, B.; Voigt, P.; Kahn, T.; Stumpp, P.; Wiltberger, G.

    2015-01-01

    This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33 % vs. 57 %, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience.

  4. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    Energy Technology Data Exchange (ETDEWEB)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kim, Sam Soo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea)

    2008-07-15

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  5. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    International Nuclear Information System (INIS)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo; Kim, Sam Soo

    2008-01-01

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  6. The short version of the Activities-specific Balance Confidence (ABC) scale: Its validity, reliability, and relationship to balance impairment and falls in older adults

    OpenAIRE

    Schepens, Stacey; Goldberg, Allon; Wallace, Melissa

    2009-01-01

    A shortened version of the ABC 16-item scale (ABC-16), the ABC-6, has been proposed as an alternative balance confidence measure. We investigated whether the ABC-6 is a valid and reliable measure of balance confidence and examined its relationship to balance impairment and falls in older adults. Thirty-five community-dwelling older adults completed the ABC-16, including the six questions of the ABC-6. They also completed the following clinical balance tests: unipedal stance time (UST), functi...

  7. Microbial ecology laboratory procedures manual NASA/MSFC

    Science.gov (United States)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  8. A systematic review of maternal confidence for physiologic birth: characteristics of prenatal care and confidence measurement.

    Science.gov (United States)

    Avery, Melissa D; Saftner, Melissa A; Larson, Bridget; Weinfurter, Elizabeth V

    2014-01-01

    Because a focus on physiologic labor and birth has reemerged in recent years, care providers have the opportunity in the prenatal period to help women increase confidence in their ability to give birth without unnecessary interventions. However, most research has only examined support for women during labor. The purpose of this systematic review was to examine the research literature for information about prenatal care approaches that increase women's confidence for physiologic labor and birth and tools to measure that confidence. Studies were reviewed that explored any element of a pregnant woman's interaction with her prenatal care provider that helped build confidence in her ability to labor and give birth. Timing of interaction with pregnant women included during pregnancy, labor and birth, and the postpartum period. In addition, we looked for studies that developed a measure of women's confidence related to labor and birth. Outcome measures included confidence or similar concepts, descriptions of components of prenatal care contributing to maternal confidence for birth, and reliability and validity of tools measuring confidence. The search of MEDLINE, CINAHL, PsycINFO, and Scopus databases provided a total of 893 citations. After removing duplicates and articles that did not meet inclusion criteria, 6 articles were included in the review. Three relate to women's confidence for labor during the prenatal period, and 3 describe tools to measure women's confidence for birth. Research about enhancing women's confidence for labor and birth was limited to qualitative studies. Results suggest that women desire information during pregnancy and want to use that information to participate in care decisions in a relationship with a trusted provider. Further research is needed to develop interventions to help midwives and physicians enhance women's confidence in their ability to give birth and to develop a tool to measure confidence for use during prenatal care. © 2014 by

  9. Implementation of remote video auditing with feedback and compliance for manual-cleaning protocols of endoscopic retrograde cholangiopancreatography endoscopes.

    Science.gov (United States)

    Armellino, Donna; Cifu, Kelly; Wallace, Maureen; Johnson, Sherly; DiCapua, John; Dowling, Oonagh; Jacobs, Mitchel; Browning, Susan

    2018-05-01

    A pilot initiative to assess the use of remote video auditing in monitoring compliance with manual-cleaning protocols for endoscopic retrograde cholangiopancreatography (ERCP) endoscopes was performed. Compliance with manual-cleaning steps following the initiation of feedback was measured. A video feed of the ERCP reprocessing room was provided to remote auditors who scored items of an ERCP endoscope manual-cleaning checklist. Compliance feedback was provided in the form of reports and reeducation. Outcomes were reported as checklist compliance. The use of remote video auditing to document manual processing is a feasible approach and feedback and reeducation increased manual-cleaning compliance from 53.1% (95% confidence interval, 34.7-71.6) to 98.9% (95.0% confidence interval, 98.1-99.6). Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. A scale for consumer confidence in the safety of food

    NARCIS (Netherlands)

    Jonge, de J.; Trijp, van J.C.M.; Lans, van der I.A.; Renes, R.J.; Frewer, L.J.

    2008-01-01

    The aim of this study was to develop and validate a scale to measure general consumer confidence in the safety of food. Results from exploratory and confirmatory analyses indicate that general consumer confidence in the safety of food consists of two distinct dimensions, optimism and pessimism,

  11. Is the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, histrionic personality disorder category a valid construct?

    Science.gov (United States)

    Bakkevig, Jonas F; Karterud, Sigmund

    2010-01-01

    The study investigated crucial aspects of the construct validity of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) histrionic personality disorder (HPD) category. The study included 2289 patients from the Norwegian Network of Psychotherapeutic Day Hospitals. Construct validity was assessed by means of prevalence, comorbidity with other personality disorders, internal consistency among HPD criteria, severity indices, as well as factor analyses. The prevalence of HPD was very low (0.4 %). The comorbidity was high, especially with borderline, narcissistic, and dependent personality disorders. The internal consistency was low. The criteria seemed to form 2 separate clusters: the first contained exhibitionistic and attention-seeking traits and the other contained impressionistic traits. The results indicated poor construct validity of the HPD category. Different options for the future of the category are discussed. The authors suggest the HPD category to be deleted from the DSM system. However, the clinical phenomena of exhibitionism and attention-seeking, which are the dominant personality features of HPD, should be preserved in an exhibitionistic subtype of narcissism. Copyright 2010 Elsevier Inc. All rights reserved.

  12. Development and Evaluation of a Confidence-Weighting Computerized Adaptive Testing

    Science.gov (United States)

    Yen, Yung-Chin; Ho, Rong-Guey; Chen, Li-Ju; Chou, Kun-Yi; Chen, Yan-Lin

    2010-01-01

    The purpose of this study was to examine whether the efficiency, precision, and validity of computerized adaptive testing (CAT) could be improved by assessing confidence differences in knowledge that examinees possessed. We proposed a novel polytomous CAT model called the confidence-weighting computerized adaptive testing (CWCAT), which combined a…

  13. LipiDex: An Integrated Software Package for High-Confidence Lipid Identification.

    Science.gov (United States)

    Hutchins, Paul D; Russell, Jason D; Coon, Joshua J

    2018-04-17

    State-of-the-art proteomics software routinely quantifies thousands of peptides per experiment with minimal need for manual validation or processing of data. For the emerging field of discovery lipidomics via liquid chromatography-tandem mass spectrometry (LC-MS/MS), comparably mature informatics tools do not exist. Here, we introduce LipiDex, a freely available software suite that unifies and automates all stages of lipid identification, reducing hands-on processing time from hours to minutes for even the most expansive datasets. LipiDex utilizes flexible in silico fragmentation templates and lipid-optimized MS/MS spectral matching routines to confidently identify and track hundreds of lipid species and unknown compounds from diverse sample matrices. Unique spectral and chromatographic peak purity algorithms accurately quantify co-isolation and co-elution of isobaric lipids, generating identifications that match the structural resolution afforded by the LC-MS/MS experiment. During final data filtering, ionization artifacts are removed to significantly reduce dataset redundancy. LipiDex interfaces with several LC-MS/MS software packages, enabling robust lipid identification to be readily incorporated into pre-existing data workflows. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Target motion measurement without implanted markers and its validation by comparison with manually obtained data

    International Nuclear Information System (INIS)

    Vences, Lucia; Wulf, Joern; Vordermark, Dirk; Sauer, Otto; Berlinger, Kajetan; Roth, Michael

    2005-01-01

    For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achieving a CT with the patient on the therapy couch, a patient's treatment position is captured. We present a method to locate tumor considering internal organ motion and displacements due to respiration. We tested the method with prostate and lung patients. The method found the most probable tumor position as well as, for high-mobility tumors located in the lung, its trajectory during the respiratory cycle. The results of this novel method were validated by comparison with manually determined target position

  15. Validation of CERBRRS against Gentilly-2 station data

    International Nuclear Information System (INIS)

    Varin, E.; Mao, J.; Kaveh, S.; Baudouin, A.

    2008-01-01

    CERBRRS models the CANDU 6 reactor regulating system (RRS) in CERBERUS transient core calculations. The validation of CERBRRS described here is performed against Gentilly-2 reactor data. The present validation focuses on the liquid zone controller (LZC) modelling, specifically the LZC fill rates. Two core transient measurements were compared to CERBRRS results: a shutdown system manual trip and the 1995 adjuster bank test. The standard CERBRRS model is found to produce a slower fill rate than observed at G2 in the SDS1 trip test. A modified LZC model was developed to reproduce the SDS1 trip test results, and compared to the 1995 adjuster bank test data. The CERBRRS results compared to the measurements show good agreement of the average LZC fill level, which is a key parameter in the RRS logic. These comparisons against Gentilly-2 station data also provide additional confidence in the overall performance of the CERBRRS. (author)

  16. Reliability and cross-cultural validation of the Turkish version of Manual Ability Classification System (MACS) for children with cerebral palsy.

    Science.gov (United States)

    Akpinar, Pinar; Tezel, Canan G; Eliasson, Ann-Christin; Icagasioglu, Afitap

    2010-01-01

    To determine the reliability and cross-cultural validation of the Turkish translation of the Manual Ability Classification System (MACS) for children with cerebral palsy (CP) and to investigate the relation to gross motor function and other comorbidities. After the forward and backward translation procedures, inter-rater and test-retest reliability was assessed between parents, physiotherapists and physicians using the intra-class correlation coefficient (ICC). Children (N = 118, 4 to 18 years, mean age 9 years 4 months; 68 boys, 50 girls) with various types of CP were classified. Additional data on the Gross Motor Function Classification System (GMFCS), intellectual delay, visual acuity, and epilepsy were collected. The inter-rater reliability was high; the ICC ranged from 0.89 to 0.96 among different professionals and parents. Between two persons of the same profession it ranged from 0.97 to 0.98. For the test-retest reliability it ranged from 0.91 to 0.98. Total agreement between the GMFCS and the MACS occurred in only 45% of the children. The level of the MACS was found to correlate with the accompanying comorbidities, namely intellectual delay and epilepsy. The Turkish version of the MACS is found to be valid and reliable, and is suggested to be appropriate for the assessment of manual ability within the Turkish population.

  17. National Radiobiology Archives Distributed Access User's Manual, Version 1. 1

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.K.; Prather, J.C.; Ligotke, E.K.; Watson, C.R.

    1992-06-01

    This supplement to the NRA Distributed Access User's manual (PNL-7877), November 1991, describes installation and use of Version 1.1 of the software package; this is not a replacement of the previous manual. Version 1.1 of the NRA Distributed Access Package is a maintenance release. It eliminates several bugs, and includes a few new features which are described in this manual. Although the appearance of some menu screens has changed, we are confident that the Version 1.0 User's Manual will provide an adequate introduction to the system. Users who are unfamiliar with Version 1.0 may wish to experiment with that version before moving on to Version 1.1.

  18. Sierra Structural Dynamics Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Garth M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-10-19

    Sierra/SD provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Sierra/SD. For a more detailed description of how to use Sierra/SD , we refer the reader to Sierra/SD, User's Notes . Many of the constructs in Sierra/SD are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Sierra/SD are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer notes manual, the user's notes and of course the material in the open literature. This page intentionally left blank.

  19. Multimodal manual therapy vs. pharmacological care for management of tension type headache: A meta-analysis of randomized trials.

    Science.gov (United States)

    Mesa-Jiménez, Juan A; Lozano-López, Cristina; Angulo-Díaz-Parreño, Santiago; Rodríguez-Fernández, Ángel L; De-la-Hoz-Aizpurua, Jose L; Fernández-de-Las-Peñas, Cesar

    2015-12-01

    Manual therapies are generally requested by patients with tension type headache. To compare the efficacy of multimodal manual therapy vs. pharmacological care for the management of tension type headache pain by conducting a meta-analysis of randomized controlled trials. PubMed, MEDLINE, EMBASE, AMED, CINAHL, EBSCO, Cochrane Database of Systematic Reviews, Cochrane Collaboration Trials Register, PEDro and SCOPUS were searched from their inception until June 2014. All randomized controlled trials comparing any manual therapy vs. medication care for treating tension type headache adults were included. Data were extracted and methodological quality assessed independently by two reviewers. We pooled headache frequency as the main outcome and also intensity and duration. The weighted mean difference between manual therapy and pharmacological care was used to determine effect sizes. Five randomized controlled trials met our inclusion criteria and were included in the meta-analysis. Pooled analyses found that manual therapies were more effective than pharmacological care in reducing frequency (weighted mean difference -0.8036, 95% confidence interval -1.66 to -0.44; three trials), intensity (weighted mean difference -0.5974, 95% confidence interval -0.8875 to -0.3073; five trials) and duration (weighted mean difference -0.5558, 95% confidence interval -0.9124 to -0.1992; three trials) of the headache immediately after treatment. No differences were found at longer follow-up for headache intensity (weighted mean difference -0.3498, 95% confidence interval -1.106 to 0.407; three trials). Manual therapies were associated with moderate effectiveness at short term, but similar effectiveness at longer follow-up for reducing headache frequency, intensity and duration in tension type headache than pharmacological medical drug care. However, due to the heterogeneity of the interventions, these results should be considered with caution at this stage. © International Headache

  20. Manual Performance Deterioration in the Cold

    NARCIS (Netherlands)

    Daanen, H.A.M.

    2009-01-01

    Manual performance during military operations in cold and windy climates is severely hampered by decreased dexterity, but valid dexterity decrease predictors based on climatic factors are scarce. Therefore, this study investigated the decrease in finger dexterity for nine combinations of ambient

  1. Fast matching of sensor data with manual observations.

    Science.gov (United States)

    Jit, Biswas; Maniyeri, Jayachandran; Louis, Shue; Philip, Yap Lin Kiat

    2009-01-01

    In systems and trials concerning wearable sensors and devices used for medical data collection, the validation of sensor data with respect to manual observations is very important. However, this is often problematic because of feigned behavior, errors in manual recording (misclassification), gaps in recording (missing readings), missed observations and timing mismatch between manual observations and sensor data due to a difference in time granularity. Using sleep activity pattern monitoring as an example we present a fast algorithm for matching sensor data with manual observations. Major components include a) signal analysis to classify states of sleep activity pattern, b) matching of states with Sleep Diary (SD) and c) automated detection of anomalies and reconciliation of mismatches between the SD and the sensor data.

  2. Guidelines for the verification and validation of expert system software and conventional software: User's manual. Volume 7

    International Nuclear Information System (INIS)

    Mirsky, S.M.; Hayes, J.E.; Miller, L.A.

    1995-03-01

    This report provides a step-by-step guide, or user manual, for personnel responsible for the planning and execution of the verification and validation (V ampersand V), and developmental testing, of expert systems, conventional software systems, and various other types of artificial intelligence systems. While the guide was developed primarily for applications in the utility industry, it applies well to all industries. The user manual has three sections. In Section 1 the user assesses the stringency of V ampersand V needed for the system under consideration, identifies the development stage the system is in, and identifies the component(s) of the system to be tested next. These three pieces of information determine which Guideline Package of V ampersand V methods is most appropriate for those conditions. The V ampersand V Guideline Packages are provided in Section 2. Each package consists of an ordered set of V ampersand V techniques to be applied to the system, guides on choosing the review/evaluation team, measurement criteria, and references to a book or report which describes the application of the method. Section 3 presents details of 11 of the most important (or least well-explained in the literature) methods to assist the user in applying these techniques accurately

  3. National Radiobiology Archives Distributed Access User`s Manual, Version 1.1. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.K.; Prather, J.C.; Ligotke, E.K.; Watson, C.R.

    1992-06-01

    This supplement to the NRA Distributed Access User`s manual (PNL-7877), November 1991, describes installation and use of Version 1.1 of the software package; this is not a replacement of the previous manual. Version 1.1 of the NRA Distributed Access Package is a maintenance release. It eliminates several bugs, and includes a few new features which are described in this manual. Although the appearance of some menu screens has changed, we are confident that the Version 1.0 User`s Manual will provide an adequate introduction to the system. Users who are unfamiliar with Version 1.0 may wish to experiment with that version before moving on to Version 1.1.

  4. Evaluating Measures of Optimism and Sport Confidence

    Science.gov (United States)

    Fogarty, Gerard J.; Perera, Harsha N.; Furst, Andrea J.; Thomas, Patrick R.

    2016-01-01

    The psychometric properties of the Life Orientation Test-Revised (LOT-R), the Sport Confidence Inventory (SCI), and the Carolina SCI (CSCI) were examined in a study involving 260 athletes. The study aimed to test the dimensional structure, convergent and divergent validity, and invariance over competition level of scores generated by these…

  5. Reliability and validity of the German short version of the Activities specific Balance Confidence (ABC-D6) scale in older adults.

    Science.gov (United States)

    Schott, Nadja

    2014-01-01

    The Activities specific Balance Confidence (ABC) is a questionnaire which was developed to assess falls-associated self-efficacy. The aim of this study was to evaluate reliability and validity of the German abbreviated 6-item version of the ABC scores in community-dwelling older people. The study sample included 384 subjects (age 71.1 ± 9.7). In order to determine the psychometric properties, reliability and validity were assessed through administration of the German adaptation of the ABC-D16 to participants twice, 10 days apart, and comparison of the ABC-D16 and the ABC-D6 with functional measures of balance and mobility (one-leg stance; 10 m walk; TUG; Fullerton Advanced Balance Scale (FAB)), physical activity (Physical Activity Scale for the Elderly (PASE)), physical fitness (30s arm curl, 30s chair stand, 6 min walk), cognition (Trail-Making-Test (TMT)), falls status, and quality of life (SF36). Factor analyses suggested a 1-factor solution for the ABC-D6 scale (explained variance 79.8%). Internal consistency (.95) and test-retest reliability (.98) for the ABC-D6 scores were excellent. Scores on the ABC-D6 were significantly lower than on the ABC-D16, but ABC-D16 and ABC-D6 scores were highly correlated (.94). There was an increasing difference in the ABC-scores between men and women with increasing age. Fallers reported lower balance confidence than non-fallers. The ABC-D6 score significantly correlated with functional measures of balance and mobility, physical activity, physical fitness, cognition, and quality of life (-.698valid instrument to asses falls-associated self-efficacy and may be used in future research projects and clinical trials. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Salinas. Theory Manual Version 2.8

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Garth M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Walsh, Timothy [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bhardwaj, Manoj K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2009-02-01

    Salinas provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Salinas. For a more detailed description of how to use Salinas , we refer the reader to Salinas, Users Notes. Many of the constructs in Salinas are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Salinas are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer notes manual, the user's notes and of course the material in the open literature.

  7. A student manual for promoting mental health among high school students.

    Science.gov (United States)

    Gigantesco, Antonella; Del Re, Debora; Cascavilla, Isabella

    2013-01-01

    We describe a school program based on a student manual for promoting mental health and preventing mental illness. A preliminary version of the manual was assessed for face validity by two focus groups. The final version was evaluated for acceptability among 253 students in 10 high schools and 1 middle school in Italy. The manual included 18 chapters (or "units") which address skills for enabling students to cope with their daily lives: communication skills, problem-solving, assertive skills, negotiation, stress management, anger management and conflict resolution. The manual was found to have been acceptable by high school students. The effectiveness of the manual in actually promoting mental health and preventing mental illness is currently being evaluated.

  8. Verification steps and personal stories in an instruction manual for seniors: Effects on confidence, motivation, and usability

    NARCIS (Netherlands)

    Loorbach, N.R.; Karreman, Joyce; Steehouder, M.F.

    2013-01-01

    Research problem: The purpose of this study was to investigate the effects of two types of motivational elements—verification steps and personal stories—in an instruction manual for a cell phone targeted at senior users (between 60 and 70 years). Research questions: What are the effects of adding

  9. Directed Design of Experiments for Validating Probability of Detection Capability of NDE Systems (DOEPOD)

    Science.gov (United States)

    Generazio, Edward R.

    2015-01-01

    Directed Design of Experiments for Validating Probability of Detection Capability of NDE Systems (DOEPOD) Manual v.1.2 The capability of an inspection system is established by applications of various methodologies to determine the probability of detection (POD). One accepted metric of an adequate inspection system is that there is 95% confidence that the POD is greater than 90% (90/95 POD). Design of experiments for validating probability of detection capability of nondestructive evaluation (NDE) systems (DOEPOD) is a methodology that is implemented via software to serve as a diagnostic tool providing detailed analysis of POD test data, guidance on establishing data distribution requirements, and resolving test issues. DOEPOD demands utilization of observance of occurrences. The DOEPOD capability has been developed to provide an efficient and accurate methodology that yields observed POD and confidence bounds for both Hit-Miss or signal amplitude testing. DOEPOD does not assume prescribed POD logarithmic or similar functions with assumed adequacy over a wide range of flaw sizes and inspection system technologies, so that multi-parameter curve fitting or model optimization approaches to generate a POD curve are not required. DOEPOD applications for supporting inspector qualifications is included.

  10. Guidelines for the verification and validation of expert system software and conventional software: User`s manual. Volume 7

    Energy Technology Data Exchange (ETDEWEB)

    Mirsky, S.M.; Hayes, J.E.; Miller, L.A. [Science Applications International Corp., McLean, VA (United States)

    1995-03-01

    This report provides a step-by-step guide, or user manual, for personnel responsible for the planning and execution of the verification and validation (V&V), and developmental testing, of expert systems, conventional software systems, and various other types of artificial intelligence systems. While the guide was developed primarily for applications in the utility industry, it applies well to all industries. The user manual has three sections. In Section 1 the user assesses the stringency of V&V needed for the system under consideration, identifies the development stage the system is in, and identifies the component(s) of the system to be tested next. These three pieces of information determine which Guideline Package of V&V methods is most appropriate for those conditions. The V&V Guideline Packages are provided in Section 2. Each package consists of an ordered set of V&V techniques to be applied to the system, guides on choosing the review/evaluation team, measurement criteria, and references to a book or report which describes the application of the method. Section 3 presents details of 11 of the most important (or least well-explained in the literature) methods to assist the user in applying these techniques accurately.

  11. Validation of the Danish PAROLE lexicon (upubliceret)

    DEFF Research Database (Denmark)

    Møller, Margrethe; Christoffersen, Ellen

    2000-01-01

    This validation is based on the Danish PAROLE lexicon dated June 20, 1998, downloaded on March 16, 1999. Subsequently, the developers of the lexicon have informed us that they have been revising the lexicon, in particular the morphological level. Morphological entries were originally generated...... automatically from a machine-readable version of the Official Danish Spelling Dictionary (Retskrivningsordbogen 1986, in the following RO86), and this resulted in some overgeneration, which the developers started eliminating after submitting the Danish PAROLE lexicon for validation. The present validation is......, however, based on the January 1997 version of the lexicon. The validation as such complies with the specifications described in ELRA validation manuals for lexical data, i.e. Underwood and Navaretta: "A Draft Manual for the Validation of Lexica, Final Report" [Underwood & Navaretta1997] and Braasch: "A...

  12. Validity of Alcohol Use Disorder Identification Test-Korean Revised Version for Screening Alcohol Use Disorder according to Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition Criteria.

    Science.gov (United States)

    Chang, Jung Wei; Kim, Jong Sung; Jung, Jin Gyu; Kim, Sung Soo; Yoon, Seok Joon; Jang, Hak Sun

    2016-11-01

    The Alcohol Use Disorder Identification Test (AUDIT) has been widely used to identify alcohol use disorder (AUD). This study evaluated the validity of the AUDIT-Korean revised version (AUDIT-KR) for screening AUD according to Diagnostic and Statistical Manual of Mental Disorders, fifth edition (DSM-5) criteria. This research was conducted with 443 subjects who visited the Chungnam National University Hospital for a comprehensive medical examination. All subjects completed the demographic questionnaire and AUDIT-KR without assistance. Subjects were divided into two groups according to DSM-5 criteria: an AUD group, which included patients that fit the criteria for AUD (120 males and 21 females), and a non-AUD group, which included 146 males and 156 females that did not meet AUD criteria. The appropriate cut-off values, sensitivity, specificity, and positive and negative predictive values of the AUDIT-KR were evaluated. The mean±standard deviation AUDIT-KR scores were 10.32±7.48 points in males and 3.23±4.42 points in females. The area under the receiver operating characteristic curve (95% confidence interval, CI) of the AUDIT-KR for identifying AUD was 0.884 (0.840-0.920) in males and 0.962 (0.923-0.985) in females. The optimal cut-off value of the AUDIT-KR was 10 points for males (sensitivity, 81.90%; specificity, 81.33%; positive predictive value, 77.2%; negative predictive value, 85.3%) and 5 points for females (sensitivity, 100.00%; specificity, 88.54%; positive predictive value, 52.6%; negative predictive value, 100.0%). The AUDIT-KR has high reliability and validity for identifying AUD according to DSM-5 criteria.

  13. Comparison Between Manual Auditing and a Natural Language Process With Machine Learning Algorithm to Evaluate Faculty Use of Standardized Reports in Radiology.

    Science.gov (United States)

    Guimaraes, Carolina V; Grzeszczuk, Robert; Bisset, George S; Donnelly, Lane F

    2018-03-01

    When implementing or monitoring department-sanctioned standardized radiology reports, feedback about individual faculty performance has been shown to be a useful driver of faculty compliance. Most commonly, these data are derived from manual audit, which can be both time-consuming and subject to sampling error. The purpose of this study was to evaluate whether a software program using natural language processing and machine learning could accurately audit radiologist compliance with the use of standardized reports compared with performed manual audits. Radiology reports from a 1-month period were loaded into such a software program, and faculty compliance with use of standardized reports was calculated. For that same period, manual audits were performed (25 reports audited for each of 42 faculty members). The mean compliance rates calculated by automated auditing were then compared with the confidence interval of the mean rate by manual audit. The mean compliance rate for use of standardized reports as determined by manual audit was 91.2% with a confidence interval between 89.3% and 92.8%. The mean compliance rate calculated by automated auditing was 92.0%, within that confidence interval. This study shows that by use of natural language processing and machine learning algorithms, an automated analysis can accurately define whether reports are compliant with use of standardized report templates and language, compared with manual audits. This may avoid significant labor costs related to conducting the manual auditing process. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  14. Confidence building in safety assessments

    International Nuclear Information System (INIS)

    Grundfelt, Bertil

    1999-01-01

    Future generations should be adequately protected from damage caused by the present disposal of radioactive waste. This presentation discusses the core of safety and performance assessment: The demonstration and building of confidence that the disposal system meets the safety requirements stipulated by society. The major difficulty is to deal with risks in the very long time perspective of the thousands of years during which the waste is hazardous. Concern about these problems has stimulated the development of the safety assessment discipline. The presentation concentrates on two of the elements of safety assessment: (1) Uncertainty and sensitivity analysis, and (2) validation and review. Uncertainty is associated both with respect to what is the proper conceptual model and with respect to parameter values for a given model. A special kind of uncertainty derives from the variation of a property in space. Geostatistics is one approach to handling spatial variability. The simplest way of doing a sensitivity analysis is to offset the model parameters one by one and observe how the model output changes. The validity of the models and data used to make predictions is central to the credibility of safety assessments for radioactive waste repositories. There are several definitions of model validation. The presentation discusses it as a process and highlights some aspects of validation methodologies

  15. A student manual for promoting mental health among high school students

    Directory of Open Access Journals (Sweden)

    Antonella Gigantesco

    2013-03-01

    Full Text Available OBJECTIVES. We describe a school program based on a student manual for promoting mental health and preventing mental illness. METHODS. A preliminary version of the manual was assessed for face validity by two focus groups. The final version was evaluated for acceptability among 253 students in 10 high schools and 1 middle school in Italy. RESULTS. The manual included 18 chapters (or "units" which address skills for enabling students to cope with their daily lives: communication skills, problem-solving, assertive skills, negotiation, stress management, anger management and conflict resolution. The manual was found to have been acceptable by high school students. CONCLUSIONS. The effectiveness of the manual in actually promoting mental health and preventing mental illness is currently being evaluated.

  16. Native Students with Problems of Addiction. A Manual for Adult Educators.

    Science.gov (United States)

    Hale, Janet Campbell; And Others

    This manual's purpose is to help adult-education instructors to deal with addictive or preaddictive behavior in their Native American students. The impact of alcohol and drug-related social problems has been devastating to Native communities. It is essential to examine broader issues such as cultural identity, ethnic pride, self-confidence, and…

  17. Work-related thumb disorders in South African physiotherapists treating musculoskeletal conditions using manual therapy techniques

    Directory of Open Access Journals (Sweden)

    Heather Jenkins

    2015-05-01

    Full Text Available Research question: What is the prevalence of and factors associated with work-related thumb problems (WRTP in South African physiotherapists treating musculoskeletal conditions using manual therapy techniques? Design: A cross-sectional, descriptive study design was used and data were collected using two Internet-based questionnaires. Participants: The sample size calculated for the study was 284 using 95% confidence levels and a 5% margin of error. There were 395 participants that were included in the study. Outcome measures: The variables measured included demographic, employment, educational and occupational factors. Results: The lifetime prevalence of WRTP in the physiotherapists was 65.3%. The manual techniques that were significantly associated with WRTP in the respondents who reported thumb problems were all grades of transverse glides applied to the spine as well as grade II–IV unilateral and central posterior-anterior pressures to the spine. The factors that remained significantly associated with WRTP in all 395 respondents after regression analysis were the cervical treatment of up to six patients a day and hyperextension > 30° of the non-dominant interphalangeal (IP joint of the thumb. Conclusion: This study confirms that a high percentage of physiotherapists using manual therapy techniques to treat musculoskeletal conditions are experiencing WRTP. Recommendations: The development of a valid and reliable WRTP screening tool is needed to aid in the identification of physiotherapists at risk and thus in the primary prevention of WRTP. A longitudinal study which follows newly qualified physiotherapists is recommended to investigate a possible cause-effect relationship and preventative strategies for WRTP in physiotherapists.

  18. Development and Validation of the Somatic Symptom Disorder-B Criteria Scale (SSD-12).

    Science.gov (United States)

    Toussaint, Anne; Murray, Alexandra M; Voigt, Katharina; Herzog, Annabel; Gierk, Benjamin; Kroenke, Kurt; Rief, Winfried; Henningsen, Peter; Löwe, Bernd

    2016-01-01

    To develop and validate a new self-report questionnaire for the assessment of the psychological features of Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition somatic symptom disorder. The Somatic Symptom Disorder-B Criteria Scale (SSD-12) was developed in several steps from an initial pool of 98 items. The SSD-12 is composed of 12 items; each of the three psychological subcriteria is measured by four items. In a cross-sectional study, the SSD-12 was administered to 698 patients (65.8% female, mean [standard deviation] age = 38.79 [14.15] years) from a psychosomatic outpatient clinic. Item and scale characteristics as well as measures of reliability and validity were determined. The SSD-12 has good item characteristics and excellent reliability (Cronbach α = .95). Confirmatory factor analyses suggested that a three-factorial structure that reflects the three psychological criteria interpreted as cognitive, affective, and behavioral aspects (n = 663, Comparative Fit Index > 0.99, Tucker-Lewis Index > 0.99, Root Mean Square Error of Approximation = 0.06, 90% confidence interval = 0.01-0.08). SSD-12 total sum score was significantly associated with somatic symptom burden (r = 0.47, p psychological symptom burden reported higher general physical and mental health impairment and significantly higher health care use. The SSD-12 is the first self-report questionnaire that operationalizes the new psychological characteristics of Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition somatic symptom disorder. Initial assessment indicates that the SSD-12 has sufficient reliability and validity to warrant further testing in both research and clinical settings.

  19. TRANSWRAP II: problem definition manual

    International Nuclear Information System (INIS)

    Knittle, D.E.

    1981-02-01

    The TRANSWRAP II computer code, written in Fortran IV and described in this Problem Definition Manual, was developed to analytically predict the magnitude of pressure pulses of large scale sodium-wate reactions in LMFBR secondary systems. It is currently being used for the Clinch River Breeder Reactor Program. The code provides the options, flexibility and features necessary to consider any system configuration. The code methodology has been validated with the aid of extensive sodium-water reaction test programs

  20. Shock outcome prediction before and after CPR: a comparative study of manual and automated active compression-decompression CPR.

    Science.gov (United States)

    Box, M S; Watson, J N; Addison, P S; Clegg, G R; Robertson, C E

    2008-09-01

    We report on a study designed to compare the relative efficacy of manual CPR (M-CPR) and automated mechanical CPR (ACD-CPR) provided by an active compression-decompression (ACD) device. The ECG signals of out-of-hospital cardiac arrest patients of cardiac aetiology were analysed just prior to, and immediately after, cardiopulmonary resuscitation (CPR) to assess the likelihood of successful defibrillation at these time points. The cardioversion outcome prediction (COP) measure previously developed by our group was used to quantify the probability of return of spontaneous circulation (ROSC) after counter-shock and was used as a measure of the efficacy of CPR. An initial validation study using COP to predict shock outcome from the patient data set resulted in a performance of 60% specificity achieved at 100% sensitivity on a blind test of the data. This is comparable with previous studies and provided confidence in the robustness of the technique across hardware platforms. Significantly, the COP marker also displayed an ability to stratify according to outcomes: asystole, ventricular fibrillation (VF), pulseless electrical activity (PEA), normal sinus rhythm (NSR). We then used the validated COP marker to analyse the ECG data record just prior to and immediately after the chest compression segments. This was initially performed for 87 CPR segments where VF was both the pre- and post-CPR waveform. An increase in the mean COP values was found for both CPR types. A signed rank sum test found the increase due to manual CPR not to be significant (p>0.05) whereas the automated CPR was found to be significant (pCPR (1.26, p=0.024) than for the manual CPR (0.99, p=0.124). These results indicate that the application of CPR does indeed provide beneficial preparation of the heart prior to defibrillation therapy whether manual or automated CPR is applied. The COP marker shows promise as a definitive, quantitative determinant of the immediate positive effect of both types of CPR

  1. Final Report for 'Verification and Validation of Radiation Hydrodynamics for Astrophysical Applications'

    International Nuclear Information System (INIS)

    Zingale, M.; Howell, L.H.

    2010-01-01

    The motivation for this work is to gain experience in the methodology of verification and validation (V and V) of astrophysical radiation hydrodynamics codes. In the first period of this work, we focused on building the infrastructure to test a single astrophysical application code, Castro, developed in collaboration between Lawrence Livermore National Laboratory (LLNL) and Lawrence Berkeley Laboratory (LBL). We delivered several hydrodynamic test problems, in the form of coded initial conditions and documentation for verification, routines to perform data analysis, and a generalized regression test suite to allow for continued automated testing. Astrophysical simulation codes aim to model phenomena that elude direct experimentation. Our only direct information about these systems comes from what we observe, and may be transient. Simulation can help further our understanding by allowing virtual experimentation of these systems. However, to have confidence in our simulations requires us to have confidence in the tools we use. Verification and Validation is a process by which we work to build confidence that a simulation code is accurately representing reality. V and V is a multistep process, and is never really complete. Once a single test problem is working as desired (i.e. that problem is verified), one wants to ensure that subsequent code changes do not break that test. At the same time, one must also search for new verification problems that test the code in a new way. It can be rather tedious to manually retest each of the problems, so before going too far with V and V, it is desirable to have an automated test suite. Our project aims to provide these basic tools for astrophysical radiation hydrodynamics codes.

  2. Robust misinterpretation of confidence intervals.

    Science.gov (United States)

    Hoekstra, Rink; Morey, Richard D; Rouder, Jeffrey N; Wagenmakers, Eric-Jan

    2014-10-01

    Null hypothesis significance testing (NHST) is undoubtedly the most common inferential technique used to justify claims in the social sciences. However, even staunch defenders of NHST agree that its outcomes are often misinterpreted. Confidence intervals (CIs) have frequently been proposed as a more useful alternative to NHST, and their use is strongly encouraged in the APA Manual. Nevertheless, little is known about how researchers interpret CIs. In this study, 120 researchers and 442 students-all in the field of psychology-were asked to assess the truth value of six particular statements involving different interpretations of a CI. Although all six statements were false, both researchers and students endorsed, on average, more than three statements, indicating a gross misunderstanding of CIs. Self-declared experience with statistics was not related to researchers' performance, and, even more surprisingly, researchers hardly outperformed the students, even though the students had not received any education on statistical inference whatsoever. Our findings suggest that many researchers do not know the correct interpretation of a CI. The misunderstandings surrounding p-values and CIs are particularly unfortunate because they constitute the main tools by which psychologists draw conclusions from data.

  3. Evaluation of ergonomic risk factors in manual patient handling ...

    African Journals Online (AJOL)

    WMSDs among nurses in West Bengal, India, evaluates the postural stresses and analyses manual patient handling risks. Responses were collected from 220 nurses by validated questionnaires. The activity and posture analyses were done through photography and by Rapid Entire Body Assessment (REBA). Results ...

  4. Educating for a Change. A Skillshop for Immigrant Community Educators. Workshop Manual.

    Science.gov (United States)

    Doris Marshall Inst. for Education and Action, Toronto (Ontario).

    This manual provides materials for a 6-day workshop for immigrant women working on the issue of woman abuse; it is intended to help them do their own programs in their own language out of their own cultural context. Objectives of the course are as follows: to increase educator skills and confidence in (1) developing learning activities and using…

  5. Development, validity and reliability testing of the East Midlands Evaluation Tool (EMET) for measuring impacts on trainees' confidence and competence following end of life care training.

    Science.gov (United States)

    Whittaker, B; Parry, R; Bird, L; Watson, S; Faull, C

    2017-02-02

    To develop, test and validate a versatile questionnaire, the East Midlands Evaluation Tool (EMET), for measuring effects of end of life care training events on trainees' self-reported confidence and competence. A paper-based questionnaire was designed on the basis of the English Department of Health's core competences for end of life care, with sections for completion pretraining, immediately post-training and also for longer term follow-up. Preliminary versions were field tested at 55 training events delivered by 13 organisations to 1793 trainees working in diverse health and social care backgrounds. Iterative rounds of development aimed to maximise relevance to events and trainees. Internal consistency was assessed by calculating interitem correlations on questionnaire responses during field testing. Content validity was assessed via qualitative content analysis of (1) responses to questionnaires completed by field tester trainers and (2) field notes from a workshop with a separate cohort of experienced trainers. Test-retest reliability was assessed via repeat administration to a cohort of student nurses. The EMET comprises 27 items with Likert-scaled responses supplemented with questions seeking free-text responses. It measures changes in self-assessed confidence and competence on 5 subscales: communication skills; assessment and care planning; symptom management; advance care planning; overarching values and knowledge. Test-retest reliability was found to be good, as was internal consistency: the questions successfully assess different aspects of the same underlying concept. The EMET provides a time-efficient, reliable and flexible means of evaluating effects of training on self-reported confidence and competence in the key elements of end of life care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Trust versus confidence: Microprocessors and personnel monitoring

    International Nuclear Information System (INIS)

    Chiaro, P.J. Jr.

    1993-01-01

    Due to recent technological advances, substantial improvements have been made in personnel contamination monitoring. In all likelihood, these advances will close out the days of manually frisking personnel for radioactive contamination. Unfortunately, as microprocessor-based monitors become more widely used, not only at commercial power reactors but also at government facilities, questions concerning their trustworthiness arise. Algorithms make decisions that were previously made by technicians. Trust is placed not in technicians but in machines. In doing this it is assumed that the machine never misses. Inevitably, this trust drops, due largely to ''false alarms''. This is especially true when monitoring for alpha contamination. What is a ''false alarm''? Do these machines and their algorithms that we put our trust in make mistakes? An analysis was performed on half-body and hand-and-foot monitors at Oak Ridge National Laboratory (ORNL) in order to justify the suggested confidence level used for alarm point determination. Sources used in this analysis had activities approximating ORNL's contamination limits

  7. Trust versus confidence: Microprocessors and personnel monitoring

    International Nuclear Information System (INIS)

    Chiaro, P.J. Jr.

    1994-01-01

    Due to recent technological advances, substantial improvements have been made in personnel contamination monitoring. In all likelihood, these advances will close out the days of manually frisking personnel for radioactive contamination. Unfortunately, as microprocessor-based monitors become more widely used, not only at commercial power reactors but also at government facilities, questions concerning their trustworthiness arise. Algorithms make decisions that were previously made by technicians. Trust is placed not in technicians but in machines. In doing this it is assumed that the machine never misses. Inevitably, this trust drops, due largely to ''false alarms''. This is especially true when monitoring for alpha contamination. What is a ''false alarm''? Do these machines and their algorithms that they put their trust in make mistakes? An analysis was performed on half-body and hand-and-foot monitors at Oak Ridge National Laboratory (ORNL) in order to justify the suggested confidence level used for alarm point determination. Sources used in this analysis had activities approximating ORNL's contamination limits

  8. Evaluation of the Swedish version of the Child Drawing: Hospital Manual.

    Science.gov (United States)

    Wennström, Berith; Nasic, Salmir; Hedelin, Hans; Bergh, Ingrid

    2011-05-01

    This paper is a report of psychometric testing of the Swedish version of the Child Drawing: Hospital Manual. Drawings have shown to be useful in assessing emotional status and anxiety in children because they generally speak to us more clearly and openly through their drawings than they are willing or able to verbally. The Child Drawing: Hospital Manual was translated into Swedish according to World Health Organization guidelines (a routine procedure for translation of English instruments) in order to assess anxiety by analysing the drawings of 59 children (5-11 years), of whom nine were girls and 50 boys undergoing day surgery during 2007-2009. Inter-rater reliability (five independent scorers) was high and internal consistency reliability was good (coefficient alpha =0·77). Parts A and C, as well as the total scale score of the Child Drawing: Hospital Manual, discriminated anxiety significantly between the group of children undergoing day surgery and a comparison group of school children, indicating adequate construct validity. For the Swedish version of the Child Drawing: Hospital Manual, our study demonstrates evidence for adequate construct validity in Parts A and C (and total scale score), high inter-rater reliability and acceptable internal consistency reliability. However, some improvements are needed before the instrument will be a clinically useful assessment of anxiety in children undergoing day surgery. © 2011 Blackwell Publishing Ltd.

  9. The accuracy of meta-metacognitive judgments: regulating the realism of confidence.

    Science.gov (United States)

    Buratti, Sandra; Allwood, Carl Martin

    2012-08-01

    Can people improve the realism of their confidence judgments about the correctness of their episodic memory reports by deselecting the least realistic judgments? An assumption of Koriat and Goldsmith's (Psychol Rev 103:490-517, 1996) model is that confidence judgments regulate the reporting of memory reports. We tested whether this assumption generalizes to the regulation of the realism (accuracy) of confidence judgments. In two experiments, 270 adults in separate conditions answered 50 recognition and recall questions about the contents of a just-seen video. After each answer, they made confidence judgments about the answer's correctness. In Experiment 1, the participants in the recognition conditions significantly increased their absolute bias when they excluded 15 questions. In Experiment 2, the participants in the recall condition significantly improved their calibration. The results indicate that recall, more than recognition, offers valid cues for participants to increase the realism of their report. However, the effects were small with only weak support for the conclusion that people have some ability to regulate the realism in their confidence judgments.

  10. Peace Corps Aquaculture Training Manual. Training Manual T0057.

    Science.gov (United States)

    Peace Corps, Washington, DC. Information Collection and Exchange Div.

    This Peace Corps training manual was developed from two existing manuals to provide a comprehensive training program in fish production for Peace Corps volunteers. The manual encompasses the essential elements of the University of Oklahoma program that has been training volunteers in aquaculture for 25 years. The 22 chapters of the manual are…

  11. Validation of a Cytotechnologist Manual Counting Service for the Ki67 Index in Neuroendocrine Tumors of the Pancreas and Gastrointestinal Tract.

    Science.gov (United States)

    Cottenden, Jennielee; Filter, Emily R; Cottreau, Jon; Moore, David; Bullock, Martin; Huang, Weei-Yuarn; Arnason, Thomas

    2018-03-01

    - Pathologists routinely assess Ki67 immunohistochemistry to grade gastrointestinal and pancreatic neuroendocrine tumors. Unfortunately, manual counts of the Ki67 index are very time consuming and eyeball estimation has been criticized as unreliable. Manual Ki67 counts performed by cytotechnologists could potentially save pathologist time and improve accuracy. - To assess the concordance between manual Ki67 index counts performed by cytotechnologists versus eyeball estimates and manual Ki67 counts by pathologists. - One Ki67 immunohistochemical stain was retrieved from each of 18 archived gastrointestinal or pancreatic neuroendocrine tumor resections. We compared pathologists' Ki67 eyeball estimates on glass slides and printed color images with manual counts performed by 3 cytotechnologists and gold standard manual Ki67 index counts by 3 pathologists. - Tumor grade agreement between pathologist image eyeball estimate and gold standard pathologist manual count was fair (κ = 0.31; 95% CI, 0.030-0.60). In 9 of 20 cases (45%), the mean pathologist eyeball estimate was 1 grade higher than the mean pathologist manual count. There was almost perfect agreement in classifying tumor grade between the mean cytotechnologist manual count and the mean pathologist manual count (κ = 0.910; 95% CI, 0.697-1.00). In 20 cases, there was only 1 grade disagreement between the 2 methods. Eyeball estimation by pathologists required less than 1 minute, whereas manual counts by pathologists required a mean of 17 minutes per case. - Eyeball estimation of the Ki67 index has a high rate of tumor grade misclassification compared with manual counting. Cytotechnologist manual counts are accurate and save pathologist time.

  12. Using the confidence interval confidently.

    Science.gov (United States)

    Hazra, Avijit

    2017-10-01

    Biomedical research is seldom done with entire populations but rather with samples drawn from a population. Although we work with samples, our goal is to describe and draw inferences regarding the underlying population. It is possible to use a sample statistic and estimates of error in the sample to get a fair idea of the population parameter, not as a single value, but as a range of values. This range is the confidence interval (CI) which is estimated on the basis of a desired confidence level. Calculation of the CI of a sample statistic takes the general form: CI = Point estimate ± Margin of error, where the margin of error is given by the product of a critical value (z) derived from the standard normal curve and the standard error of point estimate. Calculation of the standard error varies depending on whether the sample statistic of interest is a mean, proportion, odds ratio (OR), and so on. The factors affecting the width of the CI include the desired confidence level, the sample size and the variability in the sample. Although the 95% CI is most often used in biomedical research, a CI can be calculated for any level of confidence. A 99% CI will be wider than 95% CI for the same sample. Conflict between clinical importance and statistical significance is an important issue in biomedical research. Clinical importance is best inferred by looking at the effect size, that is how much is the actual change or difference. However, statistical significance in terms of P only suggests whether there is any difference in probability terms. Use of the CI supplements the P value by providing an estimate of actual clinical effect. Of late, clinical trials are being designed specifically as superiority, non-inferiority or equivalence studies. The conclusions from these alternative trial designs are based on CI values rather than the P value from intergroup comparison.

  13. Manual rotation to decrease operative delivery in posterior or transverse positions.

    Science.gov (United States)

    Le Ray, Camille; Deneux-Tharaux, Catherine; Khireddine, Imane; Dreyfus, Michel; Vardon, Delphine; Goffinet, François

    2013-09-01

    To assess the effect of a policy of manual rotation on the mode of delivery of fetuses in posterior or transverse positions at full dilatation. This was a prospective study to compare two policies of management for posterior and transverse positions in two different hospitals (Hospital 1: no manual rotation and Hospital 2: manual rotation). We used univariable and multivariable analyses to study the association between the management policy for posterior and transverse positions at full dilatation in these hospitals and maternal and neonatal outcomes. The principal end point was operative delivery (ie, cesarean or instrumental vaginal delivery). All factors associated with the risk of operative delivery in the univariable analysis (Pmanual rotation was independently associated with a reduction in operative deliveries. The rate of posterior or transverse positions at full dilatation was 15.9% (n=111) in Hospital 1 and 15.3% (n=220) in Hospital 2 (P=.75). Of the 172 attempts of manual rotation in Hospital 2, 155 (90.1%) were successful. The rate of operative delivery was significantly lower in Hospital 2, which performed manual rotations (23.2% compared with 38.7% in Hospital 1, adjusted odds ratio [OR] 0.52, 95% confidence interval [CI] 0.28-0.95). After multivariable analysis, manual rotation remained significantly associated with a reduction in the risk of operative delivery (adjusted OR 0.45, 95% CI 0.25-0.85). Five-minute Apgar score and arterial pH at birth were similar in the two hospitals. For fetuses in posterior or transverse positions at full dilatation, a strategy of manual rotation is associated with a reduction in the rate of operative delivery. III.

  14. The Job Training and Job Satisfaction Survey Technical Manual

    Science.gov (United States)

    Schmidt, Steven W.

    2004-01-01

    Job training has become an important aspect of an employee's overall job experience. However, it is not often called out specifically on instruments measuring job satisfaction. This technical manual details the processes used in the development and validation of a survey instrument to measure job training satisfaction and overall job…

  15. Financial and environmental costs of manual versus automated control of end-tidal gas concentrations.

    Science.gov (United States)

    Tay, S; Weinberg, L; Peyton, P; Story, D; Briedis, J

    2013-01-01

    Emerging technologies that reduce the economic and environmental costs of anaesthesia have had limited assessment. We hypothesised that automated control of end-tidal gases, a new feature in anaesthesia machines, will consistently reduce volatile agent consumption cost and greenhouse gas emissions. As part of the planned replacement of anaesthesia machines in a tertiary hospital, we performed a prospective before and after study comparing the cost and greenhouse gas emissions of isoflurane, sevoflurane and desflurane when using manual versus automated control of end-tidal gases. We analysed 3675 general anaesthesia cases with inhalational agents: 1865 using manual control and 1810 using automated control. Volatile agent cost was $18.87/hour using manual control and $13.82/hour using automated control: mean decrease $5.05/hour (95% confidence interval: $0.88-9.22/hour, P=0.0243). The 100-year global warming potential decreased from 23.2 kg/hour of carbon dioxide equivalents to 13.0 kg/hour: mean decrease 10.2 kg/hour (95% confidence interval: 2.7-17.7 kg/hour, P=0.0179). Automated control reduced costs by 27%. Greenhouse gas emissions decreased by 44%, a greater than expected decrease facilitated by a proportional reduction in desflurane use. Automated control of end-tidal gases increases participation in low flow anaesthesia with economic and environmental benefits.

  16. Validation of the Italian Version of the Dizziness Handicap Inventory, the Situational Vertigo Questionnaire, and the Activity-Specific Balance Confidence Scale for Peripheral and Central Vestibular Symptoms

    Directory of Open Access Journals (Sweden)

    Silvia Colnaghi

    2017-10-01

    Full Text Available Neurophysiological measurements of the vestibular function for diagnosis and follow-up evaluations provide an objective assessment, which, unfortunately, does not necessarily correlate with the patients’ self-feeling. The literature provides many questionnaires to assess the outcome of rehabilitation programs for disequilibrium, but only for the Dizziness Handicap Inventory (DHI is an Italian translation available, validated on a small group of patients suffering from a peripheral acute vertigo. We translated and validated the reliability and validity of the DHI, the Situational Vertigo Questionnaire (SVQ, and the Activities-Specific Balance Confidence Scale (ABC in 316 Italian patients complaining of dizziness due either to a peripheral or to a central vestibular deficit, or in whom vestibular signs were undetectable by means of instrumental testing or clinical evaluation. Cronbach’s coefficient alpha, the homogeneity index, and test–retest reproducibility, confirmed reliability of the Italian version of the three questionnaires. Validity was confirmed by correlation test between questionnaire scores. Correlations with clinical variables suggested that they can be used as a complementary tool for the assessment of vestibular symptoms. In conclusion, the Italian versions of DHI, SVQ, and ABC are reliable and valid questionnaires for assessing the impact of dizziness on the quality of life of Italian patients with peripheral or central vestibular deficit.

  17. Vaccination Confidence and Parental Refusal/Delay of Early Childhood Vaccines.

    Directory of Open Access Journals (Sweden)

    Melissa B Gilkey

    Full Text Available To support efforts to address parental hesitancy towards early childhood vaccination, we sought to validate the Vaccination Confidence Scale using data from a large, population-based sample of U.S. parents.We used weighted data from 9,354 parents who completed the 2011 National Immunization Survey. Parents reported on the immunization history of a 19- to 35-month-old child in their households. Healthcare providers then verified children's vaccination status for vaccines including measles, mumps, and rubella (MMR, varicella, and seasonal flu. We used separate multivariable logistic regression models to assess associations between parents' mean scores on the 8-item Vaccination Confidence Scale and vaccine refusal, vaccine delay, and vaccination status.A substantial minority of parents reported a history of vaccine refusal (15% or delay (27%. Vaccination confidence was negatively associated with refusal of any vaccine (odds ratio [OR] = 0.58, 95% confidence interval [CI], 0.54-0.63 as well as refusal of MMR, varicella, and flu vaccines specifically. Negative associations between vaccination confidence and measures of vaccine delay were more moderate, including delay of any vaccine (OR = 0.81, 95% CI, 0.76-0.86. Vaccination confidence was positively associated with having received vaccines, including MMR (OR = 1.53, 95% CI, 1.40-1.68, varicella (OR = 1.54, 95% CI, 1.42-1.66, and flu vaccines (OR = 1.32, 95% CI, 1.23-1.42.Vaccination confidence was consistently associated with early childhood vaccination behavior across multiple vaccine types. Our findings support expanding the application of the Vaccination Confidence Scale to measure vaccination beliefs among parents of young children.

  18. LitPathExplorer: a confidence-based visual text analytics tool for exploring literature-enriched pathway models.

    Science.gov (United States)

    Soto, Axel J; Zerva, Chrysoula; Batista-Navarro, Riza; Ananiadou, Sophia

    2018-04-15

    Pathway models are valuable resources that help us understand the various mechanisms underpinning complex biological processes. Their curation is typically carried out through manual inspection of published scientific literature to find information relevant to a model, which is a laborious and knowledge-intensive task. Furthermore, models curated manually cannot be easily updated and maintained with new evidence extracted from the literature without automated support. We have developed LitPathExplorer, a visual text analytics tool that integrates advanced text mining, semi-supervised learning and interactive visualization, to facilitate the exploration and analysis of pathway models using statements (i.e. events) extracted automatically from the literature and organized according to levels of confidence. LitPathExplorer supports pathway modellers and curators alike by: (i) extracting events from the literature that corroborate existing models with evidence; (ii) discovering new events which can update models; and (iii) providing a confidence value for each event that is automatically computed based on linguistic features and article metadata. Our evaluation of event extraction showed a precision of 89% and a recall of 71%. Evaluation of our confidence measure, when used for ranking sampled events, showed an average precision ranging between 61 and 73%, which can be improved to 95% when the user is involved in the semi-supervised learning process. Qualitative evaluation using pair analytics based on the feedback of three domain experts confirmed the utility of our tool within the context of pathway model exploration. LitPathExplorer is available at http://nactem.ac.uk/LitPathExplorer_BI/. sophia.ananiadou@manchester.ac.uk. Supplementary data are available at Bioinformatics online.

  19. Development of a SCAT data management manual

    International Nuclear Information System (INIS)

    Lamarche, A.; Owens, E.H.

    2005-01-01

    The Shoreline Cleanup Assessment Technique (SCAT) is a commonly used method in North America to document oiling conditions in the aftermath of an oil spill. The data generated by SCAT can support all aspects of the process needed to develop and apply shoreline treatment methods such as planning treatment strategies, selecting treatment methods, providing detailed instructions to response personnel and evaluating the response effort. In order to be effective, SCAT data must be validated, entered within computerized systems, and transformed into support documents such as maps, tables and reports. This paper describes the development of a guidance manual for SCAT data coordinators and spill response managers that use the results of SCAT data. Guidance is presented for emergency procedures that enable the generation of minimal, but adequate, SCAT data management services. The creation of the manual involved the development of formal descriptions of the role, responsibilities and abilities of the SCAT data management team. The manual provides solution to several data processing issues, including those related to the presence of multiple parallel bands of oil within a segment of shoreline. Summary tables were created to report the length of oiled shoreline by oiling category and to present surface oiling characteristics in overview maps. The manual also includes details on how SCAT data is used for response planning, decision making and to support operations. 12 refs., 7 tabs., 8 figs

  20. The Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition Defensive Functioning Scale: a validity study.

    Science.gov (United States)

    Porcerelli, John H; Cogan, Rosemary; Markova, Tsveti; Miller, Kristen; Mickens, Lavonda

    2011-01-01

    We assess the convergent and predictive validity of the Defensive Functioning Scale (DFS) with measures of life events, including childhood abuse and adult partner victimization; dimensions of psychopathology, including axis I (depressive) and axis II (borderline personality disorder) symptoms; and quality of object relations. One hundred and ten women from a university-based urban primary care clinic completed a research interview from which defense mechanisms were assessed. The quality of object relations was also assessed from interview data. The women completed self-report measures assessing depression, borderline personality disorder symptoms, childhood physical and sexual abuse, and adult partner physical and sexual victimization. Inter-rater reliability of the scoring of the DFS levels was good. High adaptive defenses were positively correlated with the quality of object relations and pathological defenses were positively correlated with childhood and adult victimization and symptom measures. Although major image distorting defenses were infrequently used, they were robustly correlated with all study variables. In a stepwise multiple regression analysis, major image distorting defenses, depressive symptoms, and minor image distorting defenses significantly predict childhood victimization, accounting for 37% of the variance. In a second stepwise multiple regression analysis, borderline personality disorder symptoms and disavowal defenses combined to significantly predict adult victimization, accounting for 16% of the variance. The DFS demonstrates good convergent validity with axis I and axis II symptoms, as well as with measures of childhood and adult victimization and object relations. The DFS levels add nonredundant information to Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition beyond axis I and axis II. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. The validity and clinical utility of purging disorder.

    Science.gov (United States)

    Keel, Pamela K; Striegel-Moore, Ruth H

    2009-12-01

    To review evidence of the validity and clinical utility of Purging Disorder and examine options for the Diagnostic and Statistical Manual of Mental Disorders fifth edition (DSM-V). Articles were identified by computerized and manual searches and reviewed to address five questions about Purging Disorder: Is there "ample" literature? Is the syndrome clearly defined? Can it be measured and diagnosed reliably? Can it be differentiated from other eating disorders? Is there evidence of syndrome validity? Although empirical classification and concurrent validity studies provide emerging support for the distinctiveness of Purging Disorder, questions remain about definition, diagnostic reliability in clinical settings, and clinical utility (i.e., prognostic validity). We discuss strengths and weaknesses associated with various options for the status of Purging Disorder in the DSM-V ranging from making no changes from DSM-IV to designating Purging Disorder a diagnosis on equal footing with Anorexia Nervosa and Bulimia Nervosa.

  2. Towards an outcome documentation in manual medicine: a first proposal of the International Classification of Functioning, Disability and Health (ICF) intervention categories for manual medicine based on a Delphi survey.

    Science.gov (United States)

    Kirchberger, I; Stucki, G; Böhni, U; Cieza, A; Kirschneck, M; Dvorak, J

    2009-09-01

    The International Classification of Functioning, Disability and Health (ICF) provides a useful framework for the comprehensive description of the patients' functional health. The aim of this study was to identify the ICF categories that represent the patients' problems treated by manual medicine practitioners in order to facilitate its application in manual medicine. This selection of ICF categories could be used for assessment, treatment documentation and quality management in manual medicine practice. Swiss manual medicine experts were asked about the patients' problems commonly treated by manual medicine practitioners in a three-round survey using the Delphi technique. Responses were linked to the ICF. Forty-eight manual medicine experts gave a total of 808 responses that were linked to 225 different ICF categories; 106 ICF categories which reached an agreement of at least 50% among the participants in the final Delphi-round were included in the set of ICF Intervention Categories for Manual Medicine; 42 (40%) of the categories are assigned to the ICF component body functions, 36 (34%) represent the ICF component body structures and 28 (26%) the ICF component activities and participation. A first proposal of ICF Intervention Categories for Manual Medicine was defined and needs to be validated in further studies.

  3. Confidant Relations in Italy

    Directory of Open Access Journals (Sweden)

    Jenny Isaacs

    2015-02-01

    Full Text Available Confidants are often described as the individuals with whom we choose to disclose personal, intimate matters. The presence of a confidant is associated with both mental and physical health benefits. In this study, 135 Italian adults responded to a structured questionnaire that asked if they had a confidant, and if so, to describe various features of the relationship. The vast majority of participants (91% reported the presence of a confidant and regarded this relationship as personally important, high in mutuality and trust, and involving minimal lying. Confidants were significantly more likely to be of the opposite sex. Participants overall were significantly more likely to choose a spouse or other family member as their confidant, rather than someone outside of the family network. Familial confidants were generally seen as closer, and of greater value, than non-familial confidants. These findings are discussed within the context of Italian culture.

  4. Buried Waste Program (BWP) data qualification manual

    International Nuclear Information System (INIS)

    Casey, C.; Larson, R.A.; Harris, G.A.

    1989-06-01

    The Data Qualification Manual (DQM) has been developed to discuss the process required to qualify data generated for the Buried Waste Program (BWP). The data from the BWP tasks conducted at the Radioactive Waste Management Complex (RWMC) and elsewhere will lead to remedial decisions being made which are governed by federal regulations administered by the Environmental Protection Agency (EPA). Data qualification is the process of insuring that only data of planned and known qualities are used to make a decision or answer a question. Although it is the Data Integrity Review Committee's (DIRC) responsibility to insure that the quality of all BWP data is ultimately verified and validated, all personnel who participate in the data gathering process will affect the quality of the data and must be responsible for knowing what is required to produce data of the planned quality. Therefore this manual is addressed to all participants in a data-gathering task. This manual discusses requirements to support data qualification in several areas, including: the sampling and analysis plan; data quality objectives and PARCC goals; sample custody documentation; quality assurance; assembly of the data qualification package; and existing data. 23 refs., 4 figs., 6 tabs

  5. Trust versus confidence: Microprocessors and personnel monitoring

    International Nuclear Information System (INIS)

    Chiaro, P.J. Jr.

    1993-01-01

    Due to recent technological advances, substantial improvements have been made in personnel contamination monitoring. In all likelihood, these advances will close out the days of manually frisking personnel for radioactive contamination. Unfortunately, as microprocessor-based monitors become more widely used, not only at commercial power reactors but also at government facilities, questions concerning their trustworthiness arise. Algorithms make decisions that were previously made by technicians. Trust is placed not in technicians but in machines. In doing this it is assumed that the machine never misses. Inevitably, this trust drops, due largely to open-quotes false alarms.close quotes This is especially true when monitoring for alpha contamination. What is a open-quotes false alarm?close quotes Do these machines and their algorithms that we put our trust in make mistakes? An analysis was performed on half-body and hand-and-foot monitors at Oak Ridge National Laboratory (ORNL) in order to justify the suggested confidence level used for alarm point determination. Sources used in this analysis had activities approximating ORNL's contamination limits

  6. A study of whether automated Diabetic Retinopathy Image Assessment could replace manual grading steps in the English National Screening Programme.

    Science.gov (United States)

    Kapetanakis, Venediktos V; Rudnicka, Alicja R; Liew, Gerald; Owen, Christopher G; Lee, Aaron; Louw, Vern; Bolter, Louis; Anderson, John; Egan, Catherine; Salas-Vega, Sebastian; Rudisill, Caroline; Taylor, Paul; Tufail, Adnan

    2015-09-01

    Diabetic retinopathy screening in England involves labour intensive manual grading of digital retinal images. We present the plan for an observational retrospective study of whether automated systems could replace one or more steps of human grading. Patients aged 12 or older who attended the Diabetes Eye Screening programme, Homerton University Hospital (London) between 1 June 2012 and 4 November 2013 had macular and disc-centred retinal images taken. All screening episodes were manually graded and will additionally be graded by three automated systems. Each system will process all screening episodes, and screening performance (sensitivity, false positive rate, likelihood ratios) and diagnostic accuracy (95% confidence intervals of screening performance measures) will be quantified. A sub-set of gradings will be validated by an approved Reading Centre. Additional analyses will explore the effect of altering thresholds for disease detection within each automated system on screening performance. 2,782/20,258 diabetes patients were referred to ophthalmologists for further examination. Prevalence of maculopathy (M1), pre-proliferative retinopathy (R2), and proliferative retinopathy (R3) were 7.9%, 3.1% and 1.2%, respectively; 4749 (23%) patients were diagnosed with background retinopathy (R1); 1.5% were considered ungradable by human graders. Retinopathy prevalence was similar to other English diabetic screening programmes, so findings should be generalizable. The study population size will allow the detection of differences in screening performance between the human and automated grading systems as small as 2%. The project will compare performance and economic costs of manual versus automated systems. © The Author(s) 2015.

  7. Groundwater Model Validation

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed E. Hassan

    2006-01-24

    Models have an inherent uncertainty. The difficulty in fully characterizing the subsurface environment makes uncertainty an integral component of groundwater flow and transport models, which dictates the need for continuous monitoring and improvement. Building and sustaining confidence in closure decisions and monitoring networks based on models of subsurface conditions require developing confidence in the models through an iterative process. The definition of model validation is postulated as a confidence building and long-term iterative process (Hassan, 2004a). Model validation should be viewed as a process not an end result. Following Hassan (2004b), an approach is proposed for the validation process of stochastic groundwater models. The approach is briefly summarized herein and detailed analyses of acceptance criteria for stochastic realizations and of using validation data to reduce input parameter uncertainty are presented and applied to two case studies. During the validation process for stochastic models, a question arises as to the sufficiency of the number of acceptable model realizations (in terms of conformity with validation data). Using a hierarchical approach to make this determination is proposed. This approach is based on computing five measures or metrics and following a decision tree to determine if a sufficient number of realizations attain satisfactory scores regarding how they represent the field data used for calibration (old) and used for validation (new). The first two of these measures are applied to hypothetical scenarios using the first case study and assuming field data consistent with the model or significantly different from the model results. In both cases it is shown how the two measures would lead to the appropriate decision about the model performance. Standard statistical tests are used to evaluate these measures with the results indicating they are appropriate measures for evaluating model realizations. The use of validation

  8. Manual and automatic locomotion scoring systems in dairy cows: A review

    NARCIS (Netherlands)

    Schlageter-Tello, A.; Bokkers, E.A.M.; Groot Koerkamp, P.W.G.; Hertem, van T.; Viazzi, S.; Romanini Bites, E.; Halachmi, I.; Bahr, C.; Berckmans, D.; Lokhorst, K.

    2014-01-01

    The objective of this review was to describe, compare and evaluate agreement, reliability, and validity of manual and automatic locomotion scoring systems (MLSSs and ALSSs, respectively) used in dairy cattle lameness research. There are many different types of MLSSs and ALSSs. Twenty-five MLSSs were

  9. A Regions of Confidence Based Approach to Enhance Segmentation with Shape Priors.

    Science.gov (United States)

    Appia, Vikram V; Ganapathy, Balaji; Abufadel, Amer; Yezzi, Anthony; Faber, Tracy

    2010-01-18

    We propose an improved region based segmentation model with shape priors that uses labels of confidence/interest to exclude the influence of certain regions in the image that may not provide useful information for segmentation. These could be regions in the image which are expected to have weak, missing or corrupt edges or they could be regions in the image which the user is not interested in segmenting, but are part of the object being segmented. In the training datasets, along with the manual segmentations we also generate an auxiliary map indicating these regions of low confidence/interest. Since, all the training images are acquired under similar conditions, we can train our algorithm to estimate these regions as well. Based on this training we will generate a map which indicates the regions in the image that are likely to contain no useful information for segmentation. We then use a parametric model to represent the segmenting curve as a combination of shape priors obtained by representing the training data as a collection of signed distance functions. We evolve an objective energy functional to evolve the global parameters that are used to represent the curve. We vary the influence each pixel has on the evolution of these parameters based on the confidence/interest label. When we use these labels to indicate the regions with low confidence; the regions containing accurate edges will have a dominant role in the evolution of the curve and the segmentation in the low confidence regions will be approximated based on the training data. Since our model evolves global parameters, it improves the segmentation even in the regions with accurate edges. This is because we eliminate the influence of the low confidence regions which may mislead the final segmentation. Similarly when we use the labels to indicate the regions which are not of importance, we will get a better segmentation of the object in the regions we are interested in.

  10. Comparison between manual and automated analysis for the quantification of carotid wall by using sonography. A validation study with CT

    International Nuclear Information System (INIS)

    Saba, Luca; Montisci, Roberto; Molinari, Filippo; Tallapally, Niranjan; Zeng, Guang; Mallarini, Giorgio; Suri, Jasjit S.

    2012-01-01

    Purpose: The purpose of this paper was to compare manual and automated analysis for the quantification of carotid wall obtained with sonography by using the computed tomography as validation technique. Material and methods: 21 consecutive patients underwent MDCTA and ultrasound analysis of carotid arteries (mean age 68 years; age range 59–81 years). The intima–media-thickness (IMT) of the 42 carotids was measured with novel and dedicated automated software analysis (called AtheroEdge™, Biomedical Technologies, Denver, CO, USA) and by four observers that manually calculated the IMT. The carotid artery wall thickness (CAWT) was also quantified in the CT datasets. Bland–Altman statistics was employed to measure the agreement between methods. A Student's t-test was used to test the differences between the IMT values of AtheroEdge™. The study obtained the IRB approval. Results: The correlation between automated AtheroEdge™ measurements and those of the human experts were equal to 95.5%, 73.5%, 88.9%, and 81.7%. The IMT coefficient of variation of the human experts was equal to 11.9%. By using a Student's t-test, the differences between the IMT values of AtheroEdge™ and those of the human experts were not found statistically significant (p value = 0.02). On comparing AtheroEdge™ (using Ultrasound) with CAWT (using CT), the results suggested a very good concordance of 84.96%. Conclusions: Data of this preliminary study indicate that automated software AtheroEdge™ can analyze with precision the IMT of carotid arteries and that the concordance with CT is optimal.

  11. Manual Physical Therapy Following Immobilization for Stable Ankle Fracture: A Case Series.

    Science.gov (United States)

    Painter, Elizabeth E; Deyle, Gail D; Allen, Christopher; Petersen, Evan J; Croy, Theodore; Rivera, Kenneth P

    2015-09-01

    Case series. Ankle fractures commonly result in persistent pain, stiffness, and functional impairments. There is insufficient evidence to favor any particular rehabilitation approach after ankle fracture. The purpose of this case series was to describe an impairment-based manual physical therapy approach to treating patients with conservatively managed ankle fractures. Patients with stable ankle fractures postimmobilization were treated with manual physical therapy and exercise targeted at associated impairments in the lower limb. The primary outcome measure was the Lower Extremity Functional Scale. Secondary outcome measures included the ankle lunge test, numeric pain-rating scale, and global rating of change. Outcome measures were collected at baseline (performed within 7 days of immobilization removal) and at 4 and 12 weeks postbaseline. Eleven patients (mean age, 39.6 years; range, 18-64 years; 2 male), after ankle fracture-related immobilization (mean duration, 48 days; range, 21-75 days), were treated for an average of 6.6 sessions (range, 3-10 sessions) over a mean of 46.1 days (range, 13-81 days). Compared to baseline, statistically significant and clinically meaningful improvements were observed in Lower Extremity Functional Scale score (P = .001; mean change, 21.9 points; 95% confidence interval: 10.4, 33.4) and in the ankle lunge test (P = .001; mean change, 7.8 cm; 95% confidence interval: 3.9, 11.7) at 4 weeks. These changes persisted at 12 weeks. Statistically significant and clinically meaningful improvements in self-reported function and ankle range of motion were observed at 4 and 12 weeks following treatment with impairment-based manual physical therapy. All patients tolerated treatment well. Results suggest that this approach may have efficacy in this population. Therapy, level 4.

  12. A manual-control approach to development of VTOL automatic landing technology.

    Science.gov (United States)

    Kelly, J. R.; Niessen, F. R.; Garren, J. F., Jr.

    1973-01-01

    The operation of VTOL aircraft in the city-center environment will require complex landing-approach trajectories that insure adequate clearance from other traffic and obstructions and provide the most direct routing for efficient operations. As part of a larger program to develop the necessary technology base, a flight investigation was undertaken to study the problems associated with manual and automatic control of steep, decelerating instrument approaches and landings. The study employed a three-cue flight director driven by control laws developed and refined during manual-control studies and subsequently applied to the automatic approach problem. The validity of this approach was demonstrated by performing the first automatic approach and landings to a predetermined spot ever accomplished with a helicopter. The manual-control studies resulted in the development of a constant-attitude deceleration profile and a low-noise navigation system.

  13. The influence of image setting on intracranial translucency measurement by manual and semi-automated system.

    Science.gov (United States)

    Zhen, Li; Yang, Xin; Ting, Yuen Ha; Chen, Min; Leung, Tak Yeung

    2013-09-01

    To investigate the agreement between manual and semi-automated system and the effect of different image settings on intracranial translucency (IT) measurement. A prospective study was conducted on 55 women carrying singleton pregnancy who attended first trimester Down syndrome screening. IT was measured both manually and by semi-automated system at the same default image setting. The IT measurements were then repeated with the post-processing changes in the image setting one at a time. The difference in IT measurements between the altered and the original images were assessed. Intracranial translucency was successfully measured on 55 images both manually and by semi-automated method. There was strong agreement in IT measurements between the two methods with a mean difference (manual minus semi-automated) of 0.011 mm (95% confidence interval--0.052 mm-0.094 mm). There were statistically significant variations in both manual and semi-automated IT measurement after changing the Gain and the Contrast. The greatest changes occurred when the Contrast was reduced to 1 (IT reduced by 0.591 mm in semi-automated; 0.565 mm in manual), followed by when the Gain was increased to 15 (IT reduced by 0.424 mm in semi-automated; 0.524 mm in manual). The image settings may affect IT identification and measurement. Increased Gain and reduced Contrast are the most influential factors and may cause under-measurement of IT. © 2013 John Wiley & Sons, Ltd.

  14. Psychometric properties of the Confidence and Trust in Delivery Questionnaire (CTDQ: a pilot study

    Directory of Open Access Journals (Sweden)

    Jeschke Elke

    2012-09-01

    Full Text Available Abstract Background Assessing expecting mother’s opinions prior to birth draws a comprehensive picture for the caregivers about their emotional state and their expectations. Some questionnaires to cover these aspects do exist. This study aims to present the psychometric properties of a new instrument, the Confidence and Trust in Delivery Questionnaire (CDTQ a short but reliable a self-report instrument that focuses on confidence and trust as meaningful dimensions for expectant mothers. Methods A pilot validation study of 221 women 6 weeks before childbirth was conducted in Germany between October 2007 and June 2008. To detect structural relations between the items, factor and reliability analyses were applied to the CTDQ items. Factor analysis was performed by means of principal components analysis and varimax rotation. Internal reliability was assessed by Cronbach’s alpha. External validation was performed using the sense of coherence (SOC scale. Results The CTDQ comprises of 11 items. We found a 4-factor structure. The internal consistency of the whole item pool (Cronbach’s α = 0.79 and the 4 subscales [confidence in labor (α = 0.82; partner’s support (α = 0.62; trust in medical competency (α = 0.68; being informed (α = 0.60] can be regarded as sufficient or even excellent. The 4 factors explained 69.6% of total variance. Except for a high intercorrelation (0.70 between “partner’s support” and “trust in medical competence”, the subscales show low intercorrelations, indicating an adequate independence of the respective subscales. Regarding the external validity we found minor respective moderate correlations with the SOC scale. Conclusions Our data suggest that the CTDQ is a useful instrument to assess confidence and trust in delivery. With 4 clinically relevant dimensions, the CTDQ is now open for further studies in the field of labor.

  15. Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects.

    Science.gov (United States)

    Sussman, Allen; Taylor, Elizabeth J; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Lawrence, Andrew; Ng, Ronald

    2012-03-01

    Patients consider multiple parameters in adjusting prandial insulin doses for optimal glycemic control. Difficulties in calculations can lead to incorrect doses or induce patients to administer fixed doses, rely on empirical estimates, or skip boluses. A multicenter study was conducted with 205 diabetes subjects who were on multiple daily injections of rapid/ short-acting insulin. Using the formula provided, the subjects manually calculated two prandial insulin doses based on one high and one normal glucose test result, respectively. They also determined the two doses using the FreeStyle InsuLinx Blood Glucose Monitoring System, which has a built-in, automated bolus calculator. After dose determinations, the subjects completed opinion surveys. Of the 409 insulin doses manually calculated by the subjects, 256 (63%) were incorrect. Only 23 (6%) of the same 409 dose determinations were incorrect using the meter, and these errors were due to either confirmed or potential deviations from the study instructions by the subjects when determining dose with meter. In the survey, 83% of the subjects expressed more confidence in the meter-calculated doses than the manually calculated doses. Furthermore, 87% of the subjects preferred to use the meter than manual calculation to determine prandial insulin doses. Insulin-using patients made errors in more than half of the manually calculated insulin doses. Use of the automated bolus calculator in the FreeStyle InsuLinx meter minimized errors in dose determination. The patients also expressed confidence and preference for using the meter. This may increase adherence and help optimize the use of mealtime insulin. © 2012 Diabetes Technology Society.

  16. We will be champions: Leaders' confidence in 'us' inspires team members' team confidence and performance.

    Science.gov (United States)

    Fransen, K; Steffens, N K; Haslam, S A; Vanbeselaere, N; Vande Broek, G; Boen, F

    2016-12-01

    The present research examines the impact of leaders' confidence in their team on the team confidence and performance of their teammates. In an experiment involving newly assembled soccer teams, we manipulated the team confidence expressed by the team leader (high vs neutral vs low) and assessed team members' responses and performance as they unfolded during a competition (i.e., in a first baseline session and a second test session). Our findings pointed to team confidence contagion such that when the leader had expressed high (rather than neutral or low) team confidence, team members perceived their team to be more efficacious and were more confident in the team's ability to win. Moreover, leaders' team confidence affected individual and team performance such that teams led by a highly confident leader performed better than those led by a less confident leader. Finally, the results supported a hypothesized mediational model in showing that the effect of leaders' confidence on team members' team confidence and performance was mediated by the leader's perceived identity leadership and members' team identification. In conclusion, the findings of this experiment suggest that leaders' team confidence can enhance members' team confidence and performance by fostering members' identification with the team. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Manual Therapy

    OpenAIRE

    Hakgüder, Aral; Kokino, Siranuş

    2002-01-01

    Manual therapy has been used in the treatment of pain and dysfunction of spinal and peripheral joints for more than a hundred years. Manual medicine includes manipulation, mobilization, and postisometric relaxation techniques. The aim of manual therapy is to enhance restricted movement caused by blockage of joints keeping postural balance, restore function and maintain optimal body mechanics. Anatomic, biomechanical, and neurophysiological evaluations of the leucomotor system is essential for...

  18. Design/CPN. A Reference Manual

    DEFF Research Database (Denmark)

    Jensen et. al, Kurt

    /CPN WWW pages. To speed up the access to the Design/CPN manuals we recommend to keep a local copy - which may be shared by all users in your organisation. In this way you do not need to go via our WWW server each time you need to look in a manual. For some of the largest manuals, we also supply files......Note: The manuals are available as PDF files . There are two sets of manuals - one for the Unix platform and another for the Mac platform. Each set of manual consists of: Tutorial (for the Design/CPN editor and simulator) Reference Manual (for the Design/CPN editor and simulator) Programmer......'s Manual (with Design/OA functions and Charts) Occurrence Graph Manual (integrated tutorial and reference manual) OE/OS Graph Manual (integrated tutorial and reference manual) Other Manuals (e.g. a short overview of CPN ML).   The Tutorial, Reference Manual and Programmer's Manual are made for Design...

  19. Cloud detection algorithm comparison and validation for operational Landsat data products

    Science.gov (United States)

    Foga, Steven Curtis; Scaramuzza, Pat; Guo, Song; Zhu, Zhe; Dilley, Ronald; Beckmann, Tim; Schmidt, Gail L.; Dwyer, John L.; Hughes, MJ; Laue, Brady

    2017-01-01

    Clouds are a pervasive and unavoidable issue in satellite-borne optical imagery. Accurate, well-documented, and automated cloud detection algorithms are necessary to effectively leverage large collections of remotely sensed data. The Landsat project is uniquely suited for comparative validation of cloud assessment algorithms because the modular architecture of the Landsat ground system allows for quick evaluation of new code, and because Landsat has the most comprehensive manual truth masks of any current satellite data archive. Currently, the Landsat Level-1 Product Generation System (LPGS) uses separate algorithms for determining clouds, cirrus clouds, and snow and/or ice probability on a per-pixel basis. With more bands onboard the Landsat 8 Operational Land Imager (OLI)/Thermal Infrared Sensor (TIRS) satellite, and a greater number of cloud masking algorithms, the U.S. Geological Survey (USGS) is replacing the current cloud masking workflow with a more robust algorithm that is capable of working across multiple Landsat sensors with minimal modification. Because of the inherent error from stray light and intermittent data availability of TIRS, these algorithms need to operate both with and without thermal data. In this study, we created a workflow to evaluate cloud and cloud shadow masking algorithms using cloud validation masks manually derived from both Landsat 7 Enhanced Thematic Mapper Plus (ETM +) and Landsat 8 OLI/TIRS data. We created a new validation dataset consisting of 96 Landsat 8 scenes, representing different biomes and proportions of cloud cover. We evaluated algorithm performance by overall accuracy, omission error, and commission error for both cloud and cloud shadow. We found that CFMask, C code based on the Function of Mask (Fmask) algorithm, and its confidence bands have the best overall accuracy among the many algorithms tested using our validation data. The Artificial Thermal-Automated Cloud Cover Algorithm (AT-ACCA) is the most accurate

  20. Investigations on the quality of manual image segmentation in 3D radiotherapy planning

    International Nuclear Information System (INIS)

    Perelmouter, J.; Tuebingen Univ.; Bohsung, J.; Nuesslin, F.; Becker, G.; Kortmann, R.D.; Bamberg, M.

    1998-01-01

    In 3D radiotherapy planning image segmentation plays an important role in the definition process of target volume and organs at risk. Here, we present a method to quantify the technical precision of the manual image segmentation process. To validate our method we developed a virtual phantom consisting of several geometrical objects of changing form and contrast, which should be contoured by volunteers using the TOMAS tool for manual segmentation of the Heidelberg VOXELPLAN system. The results of this examination are presented. (orig.) [de

  1. Raising Confident Kids

    Science.gov (United States)

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body ... Videos for Educators Search English Español Raising Confident Kids KidsHealth / For Parents / Raising Confident Kids What's in ...

  2. Caltrans : construction manual

    Science.gov (United States)

    2009-08-01

    Caltrans intends this manual as a resource for all personnel engaged in contract administration. The manual establishes policies and procedures for the construction phase of Caltrans projects. However, this manual is not a contract document. It impos...

  3. Manual on mathematical models in isotope hydrogeology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-10-01

    Methodologies based on the use of naturally occurring isotopes are, at present, an integral part of studies being undertaken for water resources assessment and management. Quantitative evaluations based on the temporal and/or spatial distribution of different isotopic species in hydrological systems require conceptual mathematical formulations. Different types of model can be employed depending on the nature of the hydrological system under investigation, the amount and type of data available, and the required accuracy of the parameter to be estimated. This manual provides an overview of the basic concepts of existing modelling approaches, procedures for their application to different hydrological systems, their limitations and data requirements. Guidance in their practical applications, illustrative case studies and information on existing PC software are also included. While the subject matter of isotope transport modelling and improved quantitative evaluations through natural isotopes in water sciences is still at the development stage, this manual summarizes the methodologies available at present, to assist the practitioner in the proper use within the framework of ongoing isotope hydrological field studies. In view of the widespread use of isotope methods in groundwater hydrology, the methodologies covered in the manual are directed towards hydrogeological applications, although most of the conceptual formulations presented would generally be valid. Refs, figs, tabs.

  4. Manual on mathematical models in isotope hydrogeology

    International Nuclear Information System (INIS)

    1996-10-01

    Methodologies based on the use of naturally occurring isotopes are, at present, an integral part of studies being undertaken for water resources assessment and management. Quantitative evaluations based on the temporal and/or spatial distribution of different isotopic species in hydrological systems require conceptual mathematical formulations. Different types of model can be employed depending on the nature of the hydrological system under investigation, the amount and type of data available, and the required accuracy of the parameter to be estimated. This manual provides an overview of the basic concepts of existing modelling approaches, procedures for their application to different hydrological systems, their limitations and data requirements. Guidance in their practical applications, illustrative case studies and information on existing PC software are also included. While the subject matter of isotope transport modelling and improved quantitative evaluations through natural isotopes in water sciences is still at the development stage, this manual summarizes the methodologies available at present, to assist the practitioner in the proper use within the framework of ongoing isotope hydrological field studies. In view of the widespread use of isotope methods in groundwater hydrology, the methodologies covered in the manual are directed towards hydrogeological applications, although most of the conceptual formulations presented would generally be valid. Refs, figs, tabs

  5. How Confident can we be in Flood Risk Assessments?

    Science.gov (United States)

    Merz, B.

    2017-12-01

    Flood risk management should be based on risk analyses quantifying the risk and its reduction for different risk reduction strategies. However, validating risk estimates by comparing model simulations with past observations is hardly possible, since the assessment typically encompasses extreme events and their impacts that have not been observed before. Hence, risk analyses are strongly based on assumptions and expert judgement. This situation opens the door for cognitive biases, such as `illusion of certainty', `overconfidence' or `recency bias'. Such biases operate specifically in complex situations with many factors involved, when uncertainty is high and events are probabilistic, or when close learning feedback loops are missing - aspects that all apply to risk analyses. This contribution discusses how confident we can be in flood risk assessments, and reflects about more rigorous approaches towards their validation.

  6. BLOCKAGE 2.5 reference manual

    International Nuclear Information System (INIS)

    Shaffer, C.J.; Brideau, J.; Rao, D.V.; Bernahl, W.

    1996-12-01

    The BLOCKAGE 2.5 code was developed by the US Nuclear Regulatory Commission (NRC) as a tool to evaluate license compliance regarding the design of suction strainers for emergency core cooling system (ECCS) pumps in boiling water reactors (BWR) as required by NRC Bulletin 96-03, ''Potential Plugging of Emergency Core Cooling Suction Strainers by Debris in Boiling Water Reactors''. Science and Engineering Associates, Inc. (SEA) and Software Edge, Inc. (SE) developed this PC-based code. The instructions to effectively use this code to evaluate the potential of debris to sufficiently block a pump suction strainer such that a pump could lose NPSH margin was documented in a User's Manual (NRC, NUREG/CR-6370). The Reference Manual contains additional information that supports the use of BLOCKAGE 2.5. It contains descriptions of the analytical models contained in the code, programmer guides illustrating the structure of the code, and summaries of coding verification and model validation exercises that were performed to ensure that the analytical models were correctly coded and applicable to the evaluation of BWR pump suction strainers. The BLOCKAGE code was developed by SEA and programmed in FORTRAN as a code that can be executed from the DOS level on a PC. A graphical users interface (GUI) was then developed by SEA to make BLOCKAGE easier to use and to provide graphical output capability. The GUI was programmed in the C language. The user has the option of executing BLOCKAGE 2.5 with the GUI or from the DOS level and the Users Manual provides instruction for both methods of execution

  7. Psychometric testing on the NLN Student Satisfaction and Self-Confidence in Learning, Simulation Design Scale, and Educational Practices Questionnaire using a sample of pre-licensure novice nurses.

    Science.gov (United States)

    Franklin, Ashley E; Burns, Paulette; Lee, Christopher S

    2014-10-01

    In 2006, the National League for Nursing published three measures related to novice nurses' beliefs about self-confidence, scenario design, and educational practices associated with simulation. Despite the extensive use of these measures, little is known about their reliability and validity. The psychometric properties of the Student Satisfaction and Self-Confidence in Learning Scale, Simulation Design Scale, and Educational Practices Questionnaire were studied among a sample of 2200 surveys completed by novice nurses from a liberal arts university in the southern United States. Psychometric tests included item analysis, confirmatory and exploratory factor analyses in randomly-split subsamples, concordant and discordant validity, and internal consistency. All three measures have sufficient reliability and validity to be used in education research. There is room for improvement in content validity with the Student Satisfaction and Self-Confidence in Learning and Simulation Design Scale. This work provides robust evidence to ensure that judgments made about self-confidence after simulation, simulation design and educational practices are valid and reliable. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis

    International Nuclear Information System (INIS)

    Chow, Tiffany W; Verhoeff, Nicolaas PLG; Takeshita, Shinichiro; Honjo, Kie; Pataky, Christina E; St Jacques, Peggy L; Kusano, Maggie L; Caldwell, Curtis B; Ramirez, Joel; Black, Sandra

    2007-01-01

    As imaging centers produce higher resolution research scans, the number of man-hours required to process regional data has become a major concern. Comparison of automated vs. manual methodology has not been reported for functional imaging. We explored validation of using automation to delineate regions of interest on positron emission tomography (PET) scans. The purpose of this study was to ascertain improvements in image processing time and reproducibility of a semi-automated brain region extraction (SABRE) method over manual delineation of regions of interest (ROIs). We compared 2 sets of partial volume corrected serotonin 1a receptor binding potentials (BPs) resulting from manual vs. semi-automated methods. BPs were obtained from subjects meeting consensus criteria for frontotemporal degeneration and from age- and gender-matched healthy controls. Two trained raters provided each set of data to conduct comparisons of inter-rater mean image processing time, rank order of BPs for 9 PET scans, intra- and inter-rater intraclass correlation coefficients (ICC), repeatability coefficients (RC), percentages of the average parameter value (RM%), and effect sizes of either method. SABRE saved approximately 3 hours of processing time per PET subject over manual delineation (p < .001). Quality of the SABRE BP results was preserved relative to the rank order of subjects by manual methods. Intra- and inter-rater ICC were high (>0.8) for both methods. RC and RM% were lower for the manual method across all ROIs, indicating less intra-rater variance across PET subjects' BPs. SABRE demonstrated significant time savings and no significant difference in reproducibility over manual methods, justifying the use of SABRE in serotonin 1a receptor radioligand PET imaging analysis. This implies that semi-automated ROI delineation is a valid methodology for future PET imaging analysis

  9. CSTEM User Manual

    Science.gov (United States)

    Hartle, M.; McKnight, R. L.

    2000-01-01

    This manual is a combination of a user manual, theory manual, and programmer manual. The reader is assumed to have some previous exposure to the finite element method. This manual is written with the idea that the CSTEM (Coupled Structural Thermal Electromagnetic-Computer Code) user needs to have a basic understanding of what the code is actually doing in order to properly use the code. For that reason, the underlying theory and methods used in the code are described to a basic level of detail. The manual gives an overview of the CSTEM code: how the code came into existence, a basic description of what the code does, and the order in which it happens (a flowchart). Appendices provide a listing and very brief description of every file used by the CSTEM code, including the type of file it is, what routine regularly accesses the file, and what routine opens the file, as well as special features included in CSTEM.

  10. GRSAC Users Manual

    International Nuclear Information System (INIS)

    Ball, S.J.; Nypaver, D.J.

    1999-01-01

    An interactive workstation-based simulation code (GRSAC) for studying postulated severe accidents in gas-cooled reactors has been developed to accommodate user-generated input with ''smart front-end'' checking. Code features includes on- and off-line plotting, on-line help and documentation, and an automated sensitivity study option. The code and its predecessors have been validated using comparisons with a variety of experimental data and similar codes. GRSAC model features include a three-dimensional representation of the core thermal hydraulics, and optional ATWS (anticipated transients without scram) capabilities. The user manual includes a detailed description of the code features, and includes four case studies which guide the user through four different examples of the major uses of GRSAC: an accident case; an initial conditions setup and run; a sensitivity study; and the setup of a new reactor model

  11. GRSAC Users Manual

    Energy Technology Data Exchange (ETDEWEB)

    Ball, S.J.; Nypaver, D.J.

    1999-02-01

    An interactive workstation-based simulation code (GRSAC) for studying postulated severe accidents in gas-cooled reactors has been developed to accommodate user-generated input with ''smart front-end'' checking. Code features includes on- and off-line plotting, on-line help and documentation, and an automated sensitivity study option. The code and its predecessors have been validated using comparisons with a variety of experimental data and similar codes. GRSAC model features include a three-dimensional representation of the core thermal hydraulics, and optional ATWS (anticipated transients without scram) capabilities. The user manual includes a detailed description of the code features, and includes four case studies which guide the user through four different examples of the major uses of GRSAC: an accident case; an initial conditions setup and run; a sensitivity study; and the setup of a new reactor model.

  12. Quantitative assessment of manual and robotic microcannulation for eye surgery using new eye model.

    Science.gov (United States)

    Tanaka, Shinichi; Harada, Kanako; Ida, Yoshiki; Tomita, Kyohei; Kato, Ippei; Arai, Fumihito; Ueta, Takashi; Noda, Yasuo; Sugita, Naohiko; Mitsuishi, Mamoru

    2015-06-01

    Microcannulation, a surgical procedure for the eye that requires drug injection into a 60-90 µm retinal vein, is difficult to perform manually. Robotic assistance has been proposed; however, its effectiveness in comparison to manual operation has not been quantified. An eye model has been developed to quantify the performance of manual and robotic microcannulation. The eye model, which is implemented with a force sensor and microchannels, also simulates the mechanical constraints of the instrument's movement. Ten subjects performed microcannulation using the model, with and without robotic assistance. The results showed that the robotic assistance was useful for motion stability when the drug was injected, whereas its positioning accuracy offered no advantage. An eye model was used to quantitatively assess the robotic microcannulation performance in comparison to manual operation. This approach could be valid for a better evaluation of surgical robotic assistance. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Diverse interpretations of confidence building

    International Nuclear Information System (INIS)

    Macintosh, J.

    1998-01-01

    This paper explores the variety of operational understandings associated with the term 'confidence building'. Collectively, these understandings constitute what should be thought of as a 'family' of confidence building approaches. This unacknowledged and generally unappreciated proliferation of operational understandings that function under the rubric of confidence building appears to be an impediment to effective policy. The paper's objective is to analyze these different understandings, stressing the important differences in their underlying assumptions. In the process, the paper underlines the need for the international community to clarify its collective thinking about what it means when it speaks of 'confidence building'. Without enhanced clarity, it will be unnecessarily difficult to employ the confidence building approach effectively due to the lack of consistent objectives and common operating assumptions. Although it is not the intention of this paper to promote a particular account of confidence building, dissecting existing operational understandings should help to identify whether there are fundamental elements that define what might be termed 'authentic' confidence building. Implicit here is the view that some operational understandings of confidence building may diverge too far from consensus models to count as meaningful members of the confidence building family. (author)

  14. Chinese Management Research Needs Self-Confidence but not Over-confidence

    DEFF Research Database (Denmark)

    Li, Xin; Ma, Li

    2018-01-01

    Chinese management research aims to contribute to global management knowledge by offering rigorous and innovative theories and practical recommendations both for managing in China and outside. However, two seemingly opposite directions that researchers are taking could prove detrimental......-confidence, limiting theoretical innovation and practical relevance. Yet going in the other direction of overly indigenous research reflects over-confidence, often isolating the Chinese management research from the mainstream academia and at times, even becoming anti-science. A more integrated approach of conducting...... to the healthy development of Chinese management research. We argue that the two directions share a common ground that lies in the mindset regarding the confidence in the work on and from China. One direction of simply following the American mainstream on academic rigor demonstrates a lack of self...

  15. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-06-18

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  16. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-03-25

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  17. The EADC-ADNI Harmonized Protocol for manual hippocampal segmentation on magnetic resonance

    DEFF Research Database (Denmark)

    Frisoni, Giovanni B; Jack, Clifford R; Bocchetta, Martina

    2015-01-01

    BACKGROUND: An international Delphi panel has defined a harmonized protocol (HarP) for the manual segmentation of the hippocampus on MR. The aim of this study is to study the concurrent validity of the HarP toward local protocols, and its major sources of variance. METHODS: Fourteen tracers segme...

  18. Effectiveness of exercise therapy and manual mobilisation in ankle sprain and functional instability: a systematic review.

    Science.gov (United States)

    van der Wees, Philip J; Lenssen, Anton F; Hendriks, Erik J M; Stomp, Derrick J; Dekker, Joost; de Bie, Rob A

    2006-01-01

    This study critically reviews the effectiveness of exercise therapy and manual mobilisation in acute ankle sprains and functional instability by conducting a systematic review of randomised controlled trials. Trials were searched electronically and manually from 1966 to March 2005. Randomised controlled trials that evaluated exercise therapy or manual mobilisation of the ankle joint with at least one clinically relevant outcome measure were included. Internal validity of the studies was independently assessed by two reviewers. When applicable, relative risk (RR) or standardised mean differences (SMD) were calculated for individual and pooled data. In total 17 studies were included. In thirteen studies the intervention included exercise therapy and in four studies the effects of manual mobilisation of the ankle joint was evaluated. Average internal validity score of the studies was 3.1 (range 1 to 7) on a 10-point scale. Exercise therapy was effective in reducing the risk of recurrent sprains after acute ankle sprain: RR 0.37 (95% CI 0.18 to 0.74), and with functional instability: RR 0.38 (95% CI 0.23 to 0.62). No effects of exercise therapy were found on postural sway in patients with functional instability: SMD: 0.38 (95% CI -0.15 to 0.91). Four studies demonstrated an initial positive effect of different modes of manual mobilisation on dorsiflexion range of motion. It is likely that exercise therapy, including the use of a wobble board, is effective in the prevention of recurrent ankle sprains. Manual mobilisation has an (initial) effect on dorsiflexion range of motion, but the clinical relevance of these findings for physiotherapy practice may be limited.

  19. Manual dexterity aptitude testing: a soap carving study.

    Science.gov (United States)

    Tang, Christopher G; Hilsinger, Raymond L; Cruz, Raul M; Schloegel, Luke J; Byl, Fred M; Rasgon, Barry M

    2014-03-01

    Currently there are few validated metrics for predicting surgical skill among otolaryngology residency applicants. To determine whether manual dexterity aptitude testing in the form of soap carving during otolaryngology residency interviews at Kaiser Permanente Medical Center Oakland predicts surgical skill at the time of graduation from otolaryngology residency programs. This study was conducted to determine how applicants with the best and worst soap carvings compared at the time of graduation with respect to various metrics including visuospatial ability and manual dexterity. Over the last 25 years, applicants to the residency program at Kaiser Permanente Oakland were required to carve soap during their residency interview. The 3 best and 3 worst soap carvings from 1990 through 2006 were determined. Of the individuals who carved those soaps, 62 qualified for the study and matriculated into otolaryngology residency programs. Surveys were sent to the 62 individuals' residency programs to evaluate those individuals on a 5-point Likert scale in various categories as well as to rank those individuals as being in the top 50% or bottom 50% of their graduating class. All else being equal, we hypothesized that applicants who had the manual dexterity and visuospatial skills to accurately carve a bar of soap would more likely possess the skills necessary to become a good surgeon. There was no difference between individuals with the best soap carvings and those with the worst soap carvings in all categories: cognitive knowledge, visuospatial ability, manual dexterity, decision making, and overall score (P > .10 for all categories). There was a 95% response rate, with 35 of 37 residency programs responding and 59 of 62 surveys returned. Manual dexterity aptitude testing in the form of soap carving does not appear to correlate with surgical skill at the time of graduation. Further studies need to be conducted to determine the role of manual dexterity and visuospatial

  20. INTRA/Mod3.2. Manual and code description. Volume 2 - User's manual

    International Nuclear Information System (INIS)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User's Manual is an input description. This document, the User's Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  1. The idiosyncratic nature of confidence.

    Science.gov (United States)

    Navajas, Joaquin; Hindocha, Chandni; Foda, Hebah; Keramati, Mehdi; Latham, Peter E; Bahrami, Bahador

    2017-11-01

    Confidence is the 'feeling of knowing' that accompanies decision making. Bayesian theory proposes that confidence is a function solely of the perceived probability of being correct. Empirical research has suggested, however, that different individuals may perform different computations to estimate confidence from uncertain evidence. To test this hypothesis, we collected confidence reports in a task where subjects made categorical decisions about the mean of a sequence. We found that for most individuals, confidence did indeed reflect the perceived probability of being correct. However, in approximately half of them, confidence also reflected a different probabilistic quantity: the perceived uncertainty in the estimated variable. We found that the contribution of both quantities was stable over weeks. We also observed that the influence of the perceived probability of being correct was stable across two tasks, one perceptual and one cognitive. Overall, our findings provide a computational interpretation of individual differences in human confidence.

  2. Mini mental state examination. Validering af en ny dansk udgave

    DEFF Research Database (Denmark)

    Korner, E.A.; Lauritzen, L.; Nilsson, F.M.

    2008-01-01

    INTRODUCTION: The Mini Mental State Examination (MMSE) is widely used in Denmark, but often in non-validated versions. In 2000 a cross-sectional workgroup decided on a new common version of the MMSE with a corresponding manual, which is validated for the first time in the present study. MATERIALS...

  3. Manual performance deterioration in the cold estimated using the wind chill equivalent temperature

    NARCIS (Netherlands)

    Daanen, H.A.M.

    2009-01-01

    Manual performance during work in cold and windy climates is severely hampered by decreased dexterity, but valid dexterity decrease predictors based on climatic factors are scarce. Therefore, this study investigated the decrease in finger- and hand dexterity and grip force for nine combinations of

  4. Structures manual

    Science.gov (United States)

    2001-01-01

    This manual was written as a guide for use by design personnel in the Vermont Agency of Transportation Structures Section. This manual covers the design responsibilities of the Section. It does not cover other functions that are a part of the Structu...

  5. Ciencias 2. Manual do Professor (Science Teacher's Manual).

    Science.gov (United States)

    Raposo, Lucilia

    This is the teacher's manual for Ciencias 2, the second in a series of elementary science textbooks for Portuguese-speaking students. The student textbook contains 10 chapters and 57 activities. The teacher's manual presents an explanation of the educational goals and the organization of the content, Topics included are environment, the human,…

  6. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  7. Radiological Control Manual

    International Nuclear Information System (INIS)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records

  8. Validation of HEDR models

    International Nuclear Information System (INIS)

    Napier, B.A.; Simpson, J.C.; Eslinger, P.W.; Ramsdell, J.V. Jr.; Thiede, M.E.; Walters, W.H.

    1994-05-01

    The Hanford Environmental Dose Reconstruction (HEDR) Project has developed a set of computer models for estimating the possible radiation doses that individuals may have received from past Hanford Site operations. This document describes the validation of these models. In the HEDR Project, the model validation exercise consisted of comparing computational model estimates with limited historical field measurements and experimental measurements that are independent of those used to develop the models. The results of any one test do not mean that a model is valid. Rather, the collection of tests together provide a level of confidence that the HEDR models are valid

  9. The Prognostic Validity of the Timed Up and Go Test With a Dual Task for Predicting the Risk of Falls in the Elderly

    Directory of Open Access Journals (Sweden)

    Martin Hofheinz

    2016-03-01

    Full Text Available Objective: The aim is to examine the prognostic validity of the Timed Up and Go Test with a cognitive and a manual dual task for predicting the risk of falls. Method: A follow-up study was performed. The data were recorded for 120 volunteers in an outpatient physiotherapy center, with a 12-month follow-up. The sample included 120 elderly men and women aged 60 to 87 years ( M age = 72.2 years living at home. The main measurements were as follows: The Timed Up and Go Test (TUG, the TUG with a cognitive dual task (TUGcog, and the TUG with a manual dual task (TUGman and falls. Results: In the 12-month follow-up, 37 persons (30.8% had a locomotive fall. The receiver operating characteristic (ROC curve shows significant results for the TUGcog. The area under the curve is 0.65 ( p = .008, with a 95% confidence interval (CI = [0.55, 0.76]. For the TUGman, the area under the curve is 0.57 with a 95% CI = [0.45, 0.68], which is not significant ( p = .256. For the TUG, the area under the curve is 0.58, which is not significant ( p = .256, 95% CI = [0.47, 0.69]. Conclusion: The TUGcog is a valid prognostic assessment to predict falls in community-dwelling elderly people.

  10. Egyptian Mythological Manuals

    DEFF Research Database (Denmark)

    Jørgensen, Jens Kristoffer Blach

    From the hands of Greek mythographers a great number of myths have survived along with philosophical discussions of their meaning and relevance for the Greeks. It is little known that something similar existed in ancient Egypt where temple libraries and archives held scholarly literature used...... by the native priesthood, much of which has only been published in recent years. As part of this corpus of texts, the ancient Egyptian mythological manuals offer a unique perspective on how the Egyptian priesthood structured and interpreted Egyptian myths. The thesis looks at the different interpretative...... techniques used in the Tebtunis Mythological Manual (Second century CE) and the Mythological Manual of the Delta (Sixth century BCE) and the place of these manuals within the larger corpus of priestly scholarly literature from ancient Egypt. To organize the wealth of local myths the manuals use model...

  11. Confidence interval procedures for Monte Carlo transport simulations

    International Nuclear Information System (INIS)

    Pederson, S.P.

    1997-01-01

    The problem of obtaining valid confidence intervals based on estimates from sampled distributions using Monte Carlo particle transport simulation codes such as MCNP is examined. Such intervals can cover the true parameter of interest at a lower than nominal rate if the sampled distribution is extremely right-skewed by large tallies. Modifications to the standard theory of confidence intervals are discussed and compared with some existing heuristics, including batched means normality tests. Two new types of diagnostics are introduced to assess whether the conditions of central limit theorem-type results are satisfied: the relative variance of the variance determines whether the sample size is sufficiently large, and estimators of the slope of the right tail of the distribution are used to indicate the number of moments that exist. A simulation study is conducted to quantify the relationship between various diagnostics and coverage rates and to find sample-based quantities useful in indicating when intervals are expected to be valid. Simulated tally distributions are chosen to emulate behavior seen in difficult particle transport problems. Measures of variation in the sample variance s 2 are found to be much more effective than existing methods in predicting when coverage will be near nominal rates. Batched means tests are found to be overly conservative in this regard. A simple but pathological MCNP problem is presented as an example of false convergence using existing heuristics. The new methods readily detect the false convergence and show that the results of the problem, which are a factor of 4 too small, should not be used. Recommendations are made for applying these techniques in practice, using the statistical output currently produced by MCNP

  12. Assessing the Agreement Between Eo-Based Semi-Automated Landslide Maps with Fuzzy Manual Landslide Delineation

    Science.gov (United States)

    Albrecht, F.; Hölbling, D.; Friedl, B.

    2017-09-01

    Landslide mapping benefits from the ever increasing availability of Earth Observation (EO) data resulting from programmes like the Copernicus Sentinel missions and improved infrastructure for data access. However, there arises the need for improved automated landslide information extraction processes from EO data while the dominant method is still manual delineation. Object-based image analysis (OBIA) provides the means for the fast and efficient extraction of landslide information. To prove its quality, automated results are often compared to manually delineated landslide maps. Although there is awareness of the uncertainties inherent in manual delineations, there is a lack of understanding how they affect the levels of agreement in a direct comparison of OBIA-derived landslide maps and manually derived landslide maps. In order to provide an improved reference, we present a fuzzy approach for the manual delineation of landslides on optical satellite images, thereby making the inherent uncertainties of the delineation explicit. The fuzzy manual delineation and the OBIA classification are compared by accuracy metrics accepted in the remote sensing community. We have tested this approach for high resolution (HR) satellite images of three large landslides in Austria and Italy. We were able to show that the deviation of the OBIA result from the manual delineation can mainly be attributed to the uncertainty inherent in the manual delineation process, a relevant issue for the design of validation processes for OBIA-derived landslide maps.

  13. Diagnostic Value of Manual and Computerized Methods of Dental Casts Analysis

    Directory of Open Access Journals (Sweden)

    H. Rahimi

    2009-06-01

    Full Text Available Objective: The aim of this study was to evaluate the validity of computerized and manual methods of dental cast analysis.Materials and Methods: Twenty set-ups of upper and lower casts using artificial teeth corresponding to various malocclusions were created for a diagnostic in vitro study. Values of tooth size were calculated from the isolated artificial teeth out of the set-ups, results were considered as a gold standard for the tooth size. Arch width was calculated from the existing set-ups on the dentins.Impressions were taken of the casts with alginate and duplicated with dental stone. Models were measured with digital caliper manually. Then images were taken from the occlusal views of the casts by a digital camera. Measurements were done on digital images with the AutoCAD software.The results of the computerized and manual methods were compared with the gold standard.Intra class correlation coefficient of reliability was used to measure the accuracy ofthe methods and the Friedman technique used to evaluate the significance of differences.Results: Results indicated that all measurements were highly correlated, e.g. gold standard and manual (0.9613-0.9991, gold standard and computerized (0.7118-0.9883, manual and computerized (0.6734-0.9914. Statistically significant differences were present between these methods (P<0.05, but they proved not to be clinically significant.Conclusion: Manual measurement is still the most accurate method when compared to the computerized measurements and the results of measurement by computer should be interpreted with caution.

  14. The Management Advisory Committee of the Inspection Validation Centre. 2nd report

    International Nuclear Information System (INIS)

    1985-06-01

    The document is the second report of the Management Advisory Committee of the Inspection Validation Centre (I.V.C.). The IVC is concerned with the ultrasonic inspection of the CEGB's proposed PWR reactor pressure vessel, and other components. The report deals with the technical progress since May 1984, and includes: interim validation, retrospective validation, examination of procedures, test assembly manufacture, interim validation of manual forging inspections, and validation facilities. (U.K.)

  15. Replication, falsification, and the crisis of confidence in social psychology.

    Science.gov (United States)

    Earp, Brian D; Trafimow, David

    2015-01-01

    The (latest) crisis in confidence in social psychology has generated much heated discussion about the importance of replication, including how it should be carried out as well as interpreted by scholars in the field. For example, what does it mean if a replication attempt "fails"-does it mean that the original results, or the theory that predicted them, have been falsified? And how should "failed" replications affect our belief in the validity of the original research? In this paper, we consider the replication debate from a historical and philosophical perspective, and provide a conceptual analysis of both replication and falsification as they pertain to this important discussion. Along the way, we highlight the importance of auxiliary assumptions (for both testing theories and attempting replications), and introduce a Bayesian framework for assessing "failed" replications in terms of how they should affect our confidence in original findings.

  16. Replication, falsification, and the crisis of confidence in social psychology

    Science.gov (United States)

    Earp, Brian D.; Trafimow, David

    2015-01-01

    The (latest) crisis in confidence in social psychology has generated much heated discussion about the importance of replication, including how it should be carried out as well as interpreted by scholars in the field. For example, what does it mean if a replication attempt “fails”—does it mean that the original results, or the theory that predicted them, have been falsified? And how should “failed” replications affect our belief in the validity of the original research? In this paper, we consider the replication debate from a historical and philosophical perspective, and provide a conceptual analysis of both replication and falsification as they pertain to this important discussion. Along the way, we highlight the importance of auxiliary assumptions (for both testing theories and attempting replications), and introduce a Bayesian framework for assessing “failed” replications in terms of how they should affect our confidence in original findings. PMID:26042061

  17. Is automatic CPAP titration as effective as manual CPAP titration in OSAHS patients? A meta-analysis.

    Science.gov (United States)

    Gao, Weijie; Jin, Yinghui; Wang, Yan; Sun, Mei; Chen, Baoyuan; Zhou, Ning; Deng, Yuan

    2012-06-01

    It is costly and time-consuming to conduct the standard manual titration to identify an effective pressure before continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea (OSA) patients. Automatic titration is cheaper and more easily available than manual titration. The purpose of this systematic review was to evaluate the effect of automatic titration in identifying a pressure and on the improvement of apnea/hyponea index (AHI) and somnolence, the change of sleep quality, and the acceptance and compliance of CPAP treatment, compared with the manual titration. A systematic search was made of the PubMed, EMBASE, Cochrane Library, SCI, China Academic Journals Full-text Databases, Chinese Biomedical Literature Database, Chinese Scientific Journals Databases and Chinese Medical Association Journals. Randomized controlled trials comparing automatic titration and manual titration were reviewed. Studies were pooled to yield odds ratios (OR) or mean differences (MD) with 95% confidence intervals (CI). Ten trials involving 849 patients met the inclusion criteria. It is hard to identify a trend in the pressures determined by either automatic or manual titration. Automatic titration can improve the AHI (MD = 0.03/h, 95% CI = -4.48 to 4.53) and Epworth sleepiness scale (SMD = -0.02, 95% CI = -0.34 to 0.31,) as effectively as the manual titration. There is no difference between sleep architecture under automatic titration or manual titration. The acceptance of CPAP treatment (OR = 0.96, 95% CI = 0.60 to 1.55) and the compliance with treatment (MD = -0.04, 95% CI = -0.17 to 0.10) after automatic titration is not different from manual titration. Automatic titration is as effective as standard manual titration in improving AHI, somnolence while maintaining sleep quality similar to the standard method. In addition, automatic titration has the same effect on the acceptance and compliance of CPAP treatment as manual titration. With the potential advantage

  18. Confidence crisis of results in biomechanics research.

    Science.gov (United States)

    Knudson, Duane

    2017-11-01

    Many biomechanics studies have small sample sizes and incorrect statistical analyses, so reporting of inaccurate inferences and inflated magnitude of effects are common in the field. This review examines these issues in biomechanics research and summarises potential solutions from research in other fields to increase the confidence in the experimental effects reported in biomechanics. Authors, reviewers and editors of biomechanics research reports are encouraged to improve sample sizes and the resulting statistical power, improve reporting transparency, improve the rigour of statistical analyses used, and increase the acceptance of replication studies to improve the validity of inferences from data in biomechanics research. The application of sports biomechanics research results would also improve if a larger percentage of unbiased effects and their uncertainty were reported in the literature.

  19. Confidence in the long-term safety of deep geological repositories. Its development and communication

    International Nuclear Information System (INIS)

    1999-01-01

    The technical aspects of confidence have been the subject of considerable debate, especially the concept of model validation. The safety case that is provided at a particular stage in the planning, construction, operation or closure of a deep geological repository is a part of a broader decision basis that guides the repository-development process. The basic steps for deriving the safety case at various stages of repository development involve: a safety assessment; and the documentation of the safety assessment, a statement of confidence in the safety indicated by the assessment, and the confirmation of the appropriateness of the safety strategy. The approaches to establish confidence in the evaluation of safety should aim to ensure that the decisions taken within the incremental process of repository development are well-founded. Various aspects of confidence in the evaluation of safety, and their integration within a safety case, are presented in detail in the present report. When communicating confidence in the findings of a safety assessment, clarity in the communication of concepts is always required. Consistent with this requirement, key concepts are specifically defined in the main text of the report. (R.P.)

  20. Welding engineering manual for constructing engineers. Pt. 2

    International Nuclear Information System (INIS)

    Neumann, A.

    1986-01-01

    The manual is a real treasure trove of knowledge and experience for the statics expert, the constructing engineer, and the welding engineer, who have to do with design and dimensioning of welding engineering work for steel structures, bridges, boilers, vessels, and pipes. Many practical examples are given together with numerous data that provide helpful information for the task of technical and economic design and dimensioning. Determination of efficient and appropriate cross-sectional dimensions and materials is the main goal of the manual. Structural steel engineering and installations subject to monitoring and inspection such as boilers, pipings, pressure vessels, and nuclear installations are the subject fields dealt with in separate chapters. The dimensioning rules presented are based on the regulations and technical codes valid in the GDR and the FRG. The catalogue of technical rules of the FRG concerning structural steel engineering and installations as above are given in supplementary chapters. (orig./HP) [de

  1. Validation of image cytometry for sperm concentration measurement

    DEFF Research Database (Denmark)

    Egeberg Palme, Dorte L.; Johannsen, Trine Holm; Petersen, Jørgen Holm

    2017-01-01

    Sperm concentration is an essential parameter in the diagnostic evaluation of men from infertile couples. It is usually determined by manual counting using a hemocytometer, and is therefore both laborious and subjective. We have earlier shown that a newly developed image cytometry (IC) method may...... be used to determine sperm concentration. Here we present a validation of the IC method by analysis of 4010 semen samples. There was high agreement between IC and manual counting at sperm concentrations above 3 mill/ml and in samples with concentrations above 12 mill/ml the two methods can be used...... a lower coefficient of variation than the manual method (5% vs 10%), indicating a better precision of the IC method. In conclusion, measurement of sperm concentration by IC can be used at concentrations above 3 mill/ml and seems more accurate and precise than manual counting, making it an attractive...

  2. Cross validation in LULOO

    DEFF Research Database (Denmark)

    Sørensen, Paul Haase; Nørgård, Peter Magnus; Hansen, Lars Kai

    1996-01-01

    The leave-one-out cross-validation scheme for generalization assessment of neural network models is computationally expensive due to replicated training sessions. Linear unlearning of examples has recently been suggested as an approach to approximative cross-validation. Here we briefly review...... the linear unlearning scheme, dubbed LULOO, and we illustrate it on a systemidentification example. Further, we address the possibility of extracting confidence information (error bars) from the LULOO ensemble....

  3. Sources of sport confidence, imagery type and performance among competitive athletes: the mediating role of sports confidence.

    Science.gov (United States)

    Levy, A R; Perry, J; Nicholls, A R; Larkin, D; Davies, J

    2015-01-01

    This study explored the mediating role of sport confidence upon (1) sources of sport confidence-performance relationship and (2) imagery-performance relationship. Participants were 157 competitive athletes who completed state measures of confidence level/sources, imagery type and performance within one hour after competition. Among the current sample, confirmatory factor analysis revealed appropriate support for the nine-factor SSCQ and the five-factor SIQ. Mediational analysis revealed that sport confidence had a mediating influence upon the achievement source of confidence-performance relationship. In addition, both cognitive and motivational imagery types were found to be important sources of confidence, as sport confidence mediated imagery type- performance relationship. Findings indicated that athletes who construed confidence from their own achievements and report multiple images on a more frequent basis are likely to benefit from enhanced levels of state sport confidence and subsequent performance.

  4. How to build confidence in climate science and politics? Return on an international conference

    International Nuclear Information System (INIS)

    Aykut, Stefan C.

    2015-01-01

    Taking as a starting point the communications at an international conference held in Paris in 2014, the article analyzes the construction of confidence in climate sciences and politics. How, by which methods and procedures, do climate modeling communities establish the validity of their models? What link can be established between the confidence in numerical simulations of global warming and in the capacity of the international system to successfully tackle the climate issue? The article shows that the existence of a close link between these different forms of confidence questions common belief that expertise should be completely separated from the political process. More generally, it examines the necessity of a 'constitution' for the science-policy relationship at the global level at a time where new paradigms for research and for policy converge toward increasing importance of regional and local levels

  5. Ceramics Analysis and Reliability Evaluation of Structures (CARES). Users and programmers manual

    Science.gov (United States)

    Nemeth, Noel N.; Manderscheid, Jane M.; Gyekenyesi, John P.

    1990-01-01

    This manual describes how to use the Ceramics Analysis and Reliability Evaluation of Structures (CARES) computer program. The primary function of the code is to calculate the fast fracture reliability or failure probability of macroscopically isotropic ceramic components. These components may be subjected to complex thermomechanical loadings, such as those found in heat engine applications. The program uses results from MSC/NASTRAN or ANSYS finite element analysis programs to evaluate component reliability due to inherent surface and/or volume type flaws. CARES utilizes the Batdorf model and the two-parameter Weibull cumulative distribution function to describe the effect of multiaxial stress states on material strength. The principle of independent action (PIA) and the Weibull normal stress averaging models are also included. Weibull material strength parameters, the Batdorf crack density coefficient, and other related statistical quantities are estimated from four-point bend bar or unifrom uniaxial tensile specimen fracture strength data. Parameter estimation can be performed for single or multiple failure modes by using the least-square analysis or the maximum likelihood method. Kolmogorov-Smirnov and Anderson-Darling goodness-of-fit tests, ninety percent confidence intervals on the Weibull parameters, and Kanofsky-Srinivasan ninety percent confidence band values are also provided. The probabilistic fast-fracture theories used in CARES, along with the input and output for CARES, are described. Example problems to demonstrate various feature of the program are also included. This manual describes the MSC/NASTRAN version of the CARES program.

  6. INTRA/Mod3.2. Manual and code description. Volume 2 - User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User`s Manual is an input description. This document, the User`s Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  7. Machine learning classification with confidence: application of transductive conformal predictors to MRI-based diagnostic and prognostic markers in depression.

    Science.gov (United States)

    Nouretdinov, Ilia; Costafreda, Sergi G; Gammerman, Alexander; Chervonenkis, Alexey; Vovk, Vladimir; Vapnik, Vladimir; Fu, Cynthia H Y

    2011-05-15

    There is rapidly accumulating evidence that the application of machine learning classification to neuroimaging measurements may be valuable for the development of diagnostic and prognostic prediction tools in psychiatry. However, current methods do not produce a measure of the reliability of the predictions. Knowing the risk of the error associated with a given prediction is essential for the development of neuroimaging-based clinical tools. We propose a general probabilistic classification method to produce measures of confidence for magnetic resonance imaging (MRI) data. We describe the application of transductive conformal predictor (TCP) to MRI images. TCP generates the most likely prediction and a valid measure of confidence, as well as the set of all possible predictions for a given confidence level. We present the theoretical motivation for TCP, and we have applied TCP to structural and functional MRI data in patients and healthy controls to investigate diagnostic and prognostic prediction in depression. We verify that TCP predictions are as accurate as those obtained with more standard machine learning methods, such as support vector machine, while providing the additional benefit of a valid measure of confidence for each prediction. Copyright © 2010 Elsevier Inc. All rights reserved.

  8. ASSESSING THE AGREEMENT BETWEEN EO-BASED SEMI-AUTOMATED LANDSLIDE MAPS WITH FUZZY MANUAL LANDSLIDE DELINEATION

    Directory of Open Access Journals (Sweden)

    F. Albrecht

    2017-09-01

    Full Text Available Landslide mapping benefits from the ever increasing availability of Earth Observation (EO data resulting from programmes like the Copernicus Sentinel missions and improved infrastructure for data access. However, there arises the need for improved automated landslide information extraction processes from EO data while the dominant method is still manual delineation. Object-based image analysis (OBIA provides the means for the fast and efficient extraction of landslide information. To prove its quality, automated results are often compared to manually delineated landslide maps. Although there is awareness of the uncertainties inherent in manual delineations, there is a lack of understanding how they affect the levels of agreement in a direct comparison of OBIA-derived landslide maps and manually derived landslide maps. In order to provide an improved reference, we present a fuzzy approach for the manual delineation of landslides on optical satellite images, thereby making the inherent uncertainties of the delineation explicit. The fuzzy manual delineation and the OBIA classification are compared by accuracy metrics accepted in the remote sensing community. We have tested this approach for high resolution (HR satellite images of three large landslides in Austria and Italy. We were able to show that the deviation of the OBIA result from the manual delineation can mainly be attributed to the uncertainty inherent in the manual delineation process, a relevant issue for the design of validation processes for OBIA-derived landslide maps.

  9. User's Manual for LEWICE Version 3.2

    Science.gov (United States)

    Wright, William

    2008-01-01

    A research project is underway at NASA Glenn to produce a computer code which can accurately predict ice growth under a wide range of meteorological conditions for any aircraft surface. This report will present a description of the code inputs and outputs from version 3.2 of this software, which is called LEWICE. This version differs from release 2.0 due to the addition of advanced thermal analysis capabilities for de-icing and anti-icing applications using electrothermal heaters or bleed air applications, the addition of automated Navier-Stokes analysis, an empirical model for supercooled large droplets (SLD) and a pneumatic boot option. An extensive effort was also undertaken to compare the results against the database of electrothermal results which have been generated in the NASA Glenn Icing Research Tunnel (IRT) as was performed for the validation effort for version 2.0. This report will primarily describe the features of the software related to the use of the program. Appendix A has been included to list some of the inner workings of the software or the physical models used. This information is also available in the form of several unpublished documents internal to NASA. This report is intended as a replacement for all previous user manuals of LEWICE. In addition to describing the changes and improvements made for this version, information from previous manuals may be duplicated so that the user will not need to consult previous manuals to use this software.

  10. Camp Health Aide Manual = Manual para trabajadores de salud.

    Science.gov (United States)

    Robinson, June Grube; And Others

    This bilingual manual serves as a textbook for migrant Camp Health Aides. Camp Health Aides are members of migrant labor camps enlisted to provide information about health and social services to migrant workers and their families. The manual is divided into 12 tabbed sections representing lessons. Teaching notes printed on contrasting paper…

  11. Validity Evidence for a Serious Game to Assess Performance on Critical Pediatric Emergency Medicine Scenarios.

    Science.gov (United States)

    Gerard, James M; Scalzo, Anthony J; Borgman, Matthew A; Watson, Christopher M; Byrnes, Chelsie E; Chang, Todd P; Auerbach, Marc; Kessler, David O; Feldman, Brian L; Payne, Brian S; Nibras, Sohail; Chokshi, Riti K; Lopreiato, Joseph O

    2018-01-26

    We developed a first-person serious game, PediatricSim, to teach and assess performances on seven critical pediatric scenarios (anaphylaxis, bronchiolitis, diabetic ketoacidosis, respiratory failure, seizure, septic shock, and supraventricular tachycardia). In the game, players are placed in the role of a code leader and direct patient management by selecting from various assessment and treatment options. The objective of this study was to obtain supportive validity evidence for the PediatricSim game scores. Game content was developed by 11 subject matter experts and followed the American Heart Association's 2011 Pediatric Advanced Life Support Provider Manual and other authoritative references. Sixty subjects with three different levels of experience were enrolled to play the game. Before game play, subjects completed a 40-item written pretest of knowledge. Game scores were compared between subject groups using scoring rubrics developed for the scenarios. Validity evidence was established and interpreted according to Messick's framework. Content validity was supported by a game development process that involved expert experience, focused literature review, and pilot testing. Subjects rated the game favorably for engagement, realism, and educational value. Interrater agreement on game scoring was excellent (intraclass correlation coefficient = 0.91, 95% confidence interval = 0.89-0.9). Game scores were higher for attendings followed by residents then medical students (Pc game and written test scores (r = 0.84, P game scores to assess knowledge of pediatric emergency medicine resuscitation.

  12. Distinguishing highly confident accurate and inaccurate memory: insights about relevant and irrelevant influences on memory confidence.

    Science.gov (United States)

    Chua, Elizabeth F; Hannula, Deborah E; Ranganath, Charan

    2012-01-01

    It is generally believed that accuracy and confidence in one's memory are related, but there are many instances when they diverge. Accordingly it is important to disentangle the factors that contribute to memory accuracy and confidence, especially those factors that contribute to confidence, but not accuracy. We used eye movements to separately measure fluent cue processing, the target recognition experience, and relative evidence assessment on recognition confidence and accuracy. Eye movements were monitored during a face-scene associative recognition task, in which participants first saw a scene cue, followed by a forced-choice recognition test for the associated face, with confidence ratings. Eye movement indices of the target recognition experience were largely indicative of accuracy, and showed a relationship to confidence for accurate decisions. In contrast, eye movements during the scene cue raised the possibility that more fluent cue processing was related to higher confidence for both accurate and inaccurate recognition decisions. In a second experiment we manipulated cue familiarity, and therefore cue fluency. Participants showed higher confidence for cue-target associations for when the cue was more familiar, especially for incorrect responses. These results suggest that over-reliance on cue familiarity and under-reliance on the target recognition experience may lead to erroneous confidence.

  13. INTRA - Maintenance and Validation. Final Report

    International Nuclear Information System (INIS)

    Edlund, Ove; Jahn, Hermann; Yitbarek, Z.

    2002-05-01

    The INTRA code is specified by the ITER Joint Central Team and the European Community as a reference code for safety analyses of Tokamak type fusion reactors. INTRA has been developed by GRS and Studsvik EcoSafe to analyse integrated behaviours such as pressurisation, chemical reactions and temperature transients inside the plasma chamber and adjacent rooms, following postulated accidents, e.g. ingress of coolant water or air. Important results of the ICE and EVITA experiments, which became available early 2001, were used to validate and improve specific INTRA models. Large efforts were spent on the behaviour of water and steam injection into a low-pressure volumes at high temperature as well as on the modelling of boiling of water in contact with hot surfaces. As a result of this a new version, INTRA/Mod4, was documented and issued. The work included implementation and validation of selected physical models in the code, maintaining code versions, preparation review and distribution of code documents, and monitoring of the code related activities being performed by the GRS under a separate contract. The INTRA/Mod4 Manual and Code Description is documented in four volumes: Volume 1 - Physical Modelling, Volume 2 - User's Manual, Volume 3 -Code Structure and Volume 4 - Validation

  14. User's manual for the master equipment list. Phase 1

    International Nuclear Information System (INIS)

    Sandoval, J.D.

    1997-01-01

    This manual is intended to provide a user with enough detailed instruction to guide them through the Master Equipment List Phase 1 (MEL Phase 1) application system operations. The MEL Phase 1 application is a database system that stores Equipment Identification Number (EIN) information to support equipment tracking in the 200E and 200W Tank Farms for the Tank Waste Remediation System Division. The MEL Phase 1 application supports both the user application and administrative control functions. The user application functions include: viewing by Folder, reporting, performing queries, and editing specific data. The administrative control functions include: maintaining valid user identifications, passwords, privileges, defining drop-down lists, and review of the change log relating to EIN data entries, additions, deletions, and editing. The scope of this User's Manual is to discuss these functions and is intended to guide users and answer questions regarding the MEL Phase 1 application

  15. HVAC system operation manual of IMEF

    International Nuclear Information System (INIS)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun.

    1997-06-01

    This manual is operation procedures of the IMEF(Irradiated Material Examination Facility) HVAC(Heating, Ventilation and Air Conditioning) System. General operation procedures and test method of the IMEF HVAC system are described. The manual is as follows; 1. HVAC system operation manual 2. HVAC system management guide 3. HVAC system maintenance manual 4. HVAC system air velocity and flowrate measurement manual 5. HVAC system HEPA filter leak test manual 6. HVAC system charcoal filter leak test manual 7. HVAC system HEPA and charcoal filter exchange manual. (author). 8 tabs

  16. Novel Automated Morphometric and Kinematic Handwriting Assessment: A Validity Study in Children with ASD and ADHD

    Science.gov (United States)

    Dirlikov, Benjamin; Younes, Laurent; Nebel, Mary Beth; Martinelli, Mary Katherine; Tiedemann, Alyssa Nicole; Koch, Carolyn A.; Fiorilli, Diana; Bastian, Amy J.; Denckla, Martha Bridge; Miller, Michael I.; Mostofsky, Stewart H.

    2017-01-01

    This study presents construct validity for a novel automated morphometric and kinematic handwriting assessment, including (1) convergent validity, establishing reliability of automated measures with traditional manual-derived Minnesota Handwriting Assessment (MHA), and (2) discriminant validity, establishing that the automated methods distinguish…

  17. Probation Officer Candidate Information Booklet and User's Manual. Standards and Training for Corrections Program.

    Science.gov (United States)

    California State Board of Corrections, Sacramento.

    This package consists of an information booklet for job candidates preparing to take California's Probation Officer Examination and a user's manual intended for those who will administer the examination. The candidate information booklet provides background information about the development and validation of the Probation Officer Examination,…

  18. Self-confidence and metacognitive processes

    Directory of Open Access Journals (Sweden)

    Kleitman Sabina

    2005-01-01

    Full Text Available This paper examines the status of Self-confidence trait. Two studies strongly suggest that Self-confidence is a component of metacognition. In the first study, participants (N=132 were administered measures of Self-concept, a newly devised Memory and Reasoning Competence Inventory (MARCI, and a Verbal Reasoning Test (VRT. The results indicate a significant relationship between confidence ratings on the VRT and the Reasoning component of MARCI. The second study (N=296 employed an extensive battery of cognitive tests and several metacognitive measures. Results indicate the presence of robust Self-confidence and Metacognitive Awareness factors, and a significant correlation between them. Self-confidence taps not only processes linked to performance on items that have correct answers, but also beliefs about events that may never occur.

  19. A Manual of Style.

    Science.gov (United States)

    Nebraska State Dept. of Education, Lincoln.

    This "Manual of Style" is offered as a guide to assist Nebraska State employees in producing quality written communications and in presenting a consistently professional image of government documents. The manual is not designed to be all-inclusive. Sections of the manual discuss formatting documents, memorandums, letters, mailing…

  20. MARS CODE MANUAL VOLUME III - Programmer's Manual

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Hwang, Moon Kyu; Jeong, Jae Jun; Kim, Kyung Doo; Bae, Sung Won; Lee, Young Jin; Lee, Won Jae

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This programmer's manual provides a complete list of overall information of code structure and input/output function of MARS. In addition, brief descriptions for each subroutine and major variables used in MARS are also included in this report, so that this report would be very useful for the code maintenance. The overall structure of the manual is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  1. Quality Manual

    Science.gov (United States)

    Koch, Michael

    The quality manual is the “heart” of every management system related to quality. Quality assurance in analytical laboratories is most frequently linked with ISO/IEC 17025, which lists the standard requirements for a quality manual. In this chapter examples are used to demonstrate, how these requirements can be met. But, certainly, there are many other ways to do this.

  2. Increasing Product Confidence-Shifting Paradigms.

    Science.gov (United States)

    Phillips, Marla; Kashyap, Vishal; Cheung, Mee-Shew

    2015-01-01

    Leaders in the pharmaceutical, medical device, and food industries expressed a unilateral concern over product confidence throughout the total product lifecycle, an unsettling fact for these leaders to manage given that their products affect the lives of millions of people each year. Fueled by the heparin incident of intentional adulteration in 2008, initial efforts for increasing product confidence were focused on improving the confidence of incoming materials, with a belief that supplier performance must be the root cause. As in the heparin case, concern over supplier performance extended deep into the supply chain to include suppliers of the suppliers-which is often a blind spot for pharmaceutical, device, and food manufacturers. Resolved to address the perceived lack of supplier performance, these U.S. Food and Drug Administration (FDA)-regulated industries began to adopt the supplier relationship management strategy, developed by the automotive industry, that emphasizes "management" of suppliers for the betterment of the manufacturers. Current product and supplier management strategies, however, have not led to a significant improvement in product confidence. As a result of the enduring concern by industry leaders over the lack of product confidence, Xavier University launched the Integrity of Supply Initiative in 2012 with a team of industry leaders and FDA officials. Through a methodical research approach, data generated by the pharmaceutical, medical device, and food manufacturers surprisingly pointed to themselves as a source of the lack of product confidence, and revealed that manufacturers either unknowingly increase the potential for error or can control/prevent many aspects of product confidence failure. It is only through this paradigm shift that manufacturers can work collaboratively with their suppliers as equal partners, instead of viewing their suppliers as "lesser" entities needing to be controlled. The basis of this shift provides manufacturers

  3. BLOCKAGE 2.5 user's manual

    International Nuclear Information System (INIS)

    Rao, D.V.; Brideau, J.; Shaffer, C.; Souto, F.; Bernahl, W.

    1996-12-01

    The BLOCKAGE 2.5 code described in this User's Manual was developed by the US Nuclear Regulatory Commission (NRC) as a tool to evaluate licensee compliance with NRC Bulletin 96-03, ''Potential Plugging of Emergency Core Cooling Suction Strainers by Debris in Boiling Water Reactors.'' As such, BLOCKAGE 2.5 provides a generalized framework into which a user can input plant-specific and insulation-specific data for performing analyses in accordance with Regulatory Guide 1.82, Rev. 2. This user's manual describes the capabilities of BLOCKAGE 2.5 along with a description of the graphics user's interface provided for data entry. Each input/output dialog is described in detail along with special considerations related to developing and executing BLOCKAGE. Also, several sample problems are provided such that user can easily modify them to suit a particular plant of interest. The models used in BLOCKAGE 2.5 and their validation are presented in the accompanying NUREG/CR-6371. The BLOCKAGE models were designed to be parametric in nature, allowing the user flexibility to examine the impact of several modeling assumptions and to conduct sensitivity analyses. As a result, BLOCKAGE 2.5 results are known to be very sensitive to the user provided input. It is therefore strongly recommended that users become thoroughly familiar with BLOCKAGE models and their limitations as described in NUREG/CR-6224

  4. Manual therapy and exercise for rotator cuff disease.

    Science.gov (United States)

    Page, Matthew J; Green, Sally; McBain, Brodwen; Surace, Stephen J; Deitch, Jessica; Lyttle, Nicolette; Mrocki, Marshall A; Buchbinder, Rachelle

    2016-06-10

    43 trials. We were unable to perform any meta-analyses because of clinical heterogeneity or incomplete outcome reporting. One trial compared manual therapy and exercise with placebo (inactive ultrasound therapy) in 120 participants with chronic rotator cuff disease (high quality evidence). At 22 weeks, the mean change in overall pain with placebo was 17.3 points on a 100-point scale, and 24.8 points with manual therapy and exercise (adjusted mean difference (MD) 6.8 points, 95% confidence interval (CI) -0.70 to 14.30 points; absolute risk difference 7%, 1% fewer to 14% more). Mean change in function with placebo was 15.6 points on a 100-point scale, and 22.4 points with manual therapy and exercise (adjusted MD 7.1 points, 95% CI 0.30 to 13.90 points; absolute risk difference 7%, 1% to 14% more). Fifty-seven per cent (31/54) of participants reported treatment success with manual therapy and exercise compared with 41% (24/58) of participants receiving placebo (risk ratio (RR) 1.39, 95% CI 0.94 to 2.03; absolute risk difference 16% (2% fewer to 34% more). Thirty-one per cent (17/55) of participants reported adverse events with manual therapy and exercise compared with 8% (5/61) of participants receiving placebo (RR 3.77, 95% CI 1.49 to 9.54; absolute risk difference 23% (9% to 37% more). However adverse events were mild (short-term pain following treatment).Five trials (low quality evidence) found no important differences between manual therapy and exercise compared with glucocorticoid injection with respect to overall pain, function, active shoulder abduction and quality of life from four weeks up to 12 months. However, global treatment success was more common up to 11 weeks in people receiving glucocorticoid injection (low quality evidence). One trial (low quality evidence) showed no important differences between manual therapy and exercise and arthroscopic subacromial decompression with respect to overall pain, function, active range of motion and strength at six and

  5. SimPhospho: a software tool enabling confident phosphosite assignment.

    Science.gov (United States)

    Suni, Veronika; Suomi, Tomi; Tsubosaka, Tomoya; Imanishi, Susumu Y; Elo, Laura L; Corthals, Garry L

    2018-03-27

    Mass spectrometry combined with enrichment strategies for phosphorylated peptides has been successfully employed for two decades to identify sites of phosphorylation. However, unambiguous phosphosite assignment is considered challenging. Given that site-specific phosphorylation events function as different molecular switches, validation of phosphorylation sites is of utmost importance. In our earlier study we developed a method based on simulated phosphopeptide spectral libraries, which enables highly sensitive and accurate phosphosite assignments. To promote more widespread use of this method, we here introduce a software implementation with improved usability and performance. We present SimPhospho, a fast and user-friendly tool for accurate simulation of phosphopeptide tandem mass spectra. Simulated phosphopeptide spectral libraries are used to validate and supplement database search results, with a goal to improve reliable phosphoproteome identification and reporting. The presented program can be easily used together with the Trans-Proteomic Pipeline and integrated in a phosphoproteomics data analysis workflow. SimPhospho is available for Windows, Linux and Mac operating systems at https://sourceforge.net/projects/simphospho/. It is open source and implemented in C ++. A user's manual with detailed description of data analysis using SimPhospho as well as test data can be found as supplementary material of this article. Supplementary data are available at https://www.btk.fi/research/ computational-biomedicine/software/.

  6. SHARP User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Y. Q. [Argonne National Lab. (ANL), Argonne, IL (United States); Shemon, E. R. [Argonne National Lab. (ANL), Argonne, IL (United States); Thomas, J. W. [Argonne National Lab. (ANL), Argonne, IL (United States); Mahadevan, Vijay S. [Argonne National Lab. (ANL), Argonne, IL (United States); Rahaman, Ronald O. [Argonne National Lab. (ANL), Argonne, IL (United States); Solberg, Jerome [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-03-31

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  7. SHARP User Manual

    International Nuclear Information System (INIS)

    Yu, Y. Q.; Shemon, E. R.; Thomas, J. W.; Mahadevan, Vijay S.; Rahaman, Ronald O.; Solberg, Jerome

    2016-01-01

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  8. Validation of the USGS Landsat Burned Area Essential Climate Variable (BAECV) across the conterminous United States

    Science.gov (United States)

    Vanderhoof, Melanie; Fairaux, Nicole; Beal, Yen-Ju G.; Hawbaker, Todd J.

    2017-01-01

    The Landsat Burned Area Essential Climate Variable (BAECV), developed by the U.S. Geological Survey (USGS), capitalizes on the long temporal availability of Landsat imagery to identify burned areas across the conterminous United States (CONUS) (1984–2015). Adequate validation of such products is critical for their proper usage and interpretation. Validation of coarse-resolution products often relies on independent data derived from moderate-resolution sensors (e.g., Landsat). Validation of Landsat products, in turn, is challenging because there is no corresponding source of high-resolution, multispectral imagery that has been systematically collected in space and time over the entire temporal extent of the Landsat archive. Because of this, comparison between high-resolution images and Landsat science products can help increase user's confidence in the Landsat science products, but may not, alone, be adequate. In this paper, we demonstrate an approach to systematically validate the Landsat-derived BAECV product. Burned area extent was mapped for Landsat image pairs using a manually trained semi-automated algorithm that was manually edited across 28 path/rows and five different years (1988, 1993, 1998, 2003, 2008). Three datasets were independently developed by three analysts and the datasets were integrated on a pixel by pixel basis in which at least one to all three analysts were required to agree a pixel was burned. We found that errors within our Landsat reference dataset could be minimized by using the rendition of the dataset in which pixels were mapped as burned if at least two of the three analysts agreed. BAECV errors of omission and commission for the detection of burned pixels averaged 42% and 33%, respectively for CONUS across all five validation years. Errors of omission and commission were lowest across the western CONUS, for example in the shrub and scrublands of the Arid West (31% and 24%, respectively), and highest in the grasslands and

  9. GPM GROUND VALIDATION ENVIRONMENT CANADA (EC) SNOW SURVEYS GCPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Environment Canada Snow Surveys GCPEx dataset was manually collected during the GPM Cold-season Precipitation Experiment (GCPEx), which...

  10. Distinguishing highly confident accurate and inaccurate memory: insights about relevant and irrelevant influences on memory confidence

    OpenAIRE

    Chua, Elizabeth F.; Hannula, Deborah E.; Ranganath, Charan

    2012-01-01

    It is generally believed that accuracy and confidence in one’s memory are related, but there are many instances when they diverge. Accordingly, it is important to disentangle the factors which contribute to memory accuracy and confidence, especially those factors that contribute to confidence, but not accuracy. We used eye movements to separately measure fluent cue processing, the target recognition experience, and relative evidence assessment on recognition confidence and accuracy. Eye movem...

  11. Different approaches to synovial membrane volume determination by magnetic resonance imaging: manual versus automated segmentation

    DEFF Research Database (Denmark)

    Østergaard, Mikkel

    1997-01-01

    Automated fast (5-20 min) synovial membrane volume determination by MRI, based on pre-set post-gadolinium-DTPA enhancement thresholds, was evaluated as a substitute for a time-consuming (45-120 min), previously validated, manual segmentation method. Twenty-nine knees [rheumatoid arthritis (RA) 13...

  12. Poststroke delirium incidence and outcomes: validation of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU).

    Science.gov (United States)

    Mitasova, Adela; Kostalova, Milena; Bednarik, Josef; Michalcakova, Radka; Kasparek, Tomas; Balabanova, Petra; Dusek, Ladislav; Vohanka, Stanislav; Ely, E Wesley

    2012-02-01

    To describe the epidemiology and time spectrum of delirium using Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria and to validate a tool for delirium assessment in patients in the acute poststroke period. A prospective observational cohort study. The stroke unit of a university hospital. A consecutive series of 129 patients with stroke (with infarction or intracerebral hemorrhage, 57 women and 72 men; mean age, 72.5 yrs; age range, 35-93 yrs) admitted to the stroke unit of a university hospital were evaluated for delirium incidence. None. Criterion validity and overall accuracy of the Czech version of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) were determined using serial daily delirium assessments with CAM-ICU by a junior physician compared with delirium diagnosis by delirium experts using the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria that began the first day after stroke onset and continued for at least 7 days. Cox regression models using time-dependent covariate analysis adjusting for age, gender, prestroke dementia, National Institutes of Stroke Health Care at admission, first-day Sequential Organ Failure Assessment, and asphasia were used to understand the relationships between delirium and clinical outcomes. An episode of delirium based on reference Diagnostic and Statistical Manual assessment was detected in 55 patients with stroke (42.6%). In 37 of these (67.3%), delirium began within the first day and in all of them within 5 days of stroke onset. A total of 1003 paired CAM-ICU/Diagnostic and Statistical Manual of Mental Disorders daily assessments were completed. Compared with the reference standard for diagnosing delirium, the CAM-ICU demonstrated a sensitivity of 76% (95% confidence interval [CI] 55% to 91%), a specificity of 98% (95% CI 93% to 100%), an overall accuracy of 94% (95% CI 88% to 97%), and high interrater reliability (κ = 0.94; 95% CI 0

  13. Evaluation of manual and automatic manually triggered ventilation performance and ergonomics using a simulation model.

    Science.gov (United States)

    Marjanovic, Nicolas; Le Floch, Soizig; Jaffrelot, Morgan; L'Her, Erwan

    2014-05-01

    In the absence of endotracheal intubation, the manual bag-valve-mask (BVM) is the most frequently used ventilation technique during resuscitation. The efficiency of other devices has been poorly studied. The bench-test study described here was designed to evaluate the effectiveness of an automatic, manually triggered system, and to compare it with manual BVM ventilation. A respiratory system bench model was assembled using a lung simulator connected to a manikin to simulate a patient with unprotected airways. Fifty health-care providers from different professional groups (emergency physicians, residents, advanced paramedics, nurses, and paramedics; n = 10 per group) evaluated manual BVM ventilation, and compared it with an automatic manually triggered device (EasyCPR). Three pathological situations were simulated (restrictive, obstructive, normal). Standard ventilation parameters were recorded; the ergonomics of the system were assessed by the health-care professionals using a standard numerical scale once the recordings were completed. The tidal volume fell within the standard range (400-600 mL) for 25.6% of breaths (0.6-45 breaths) using manual BVM ventilation, and for 28.6% of breaths (0.3-80 breaths) using the automatic manually triggered device (EasyCPR) (P < .0002). Peak inspiratory airway pressure was lower using the automatic manually triggered device (EasyCPR) (10.6 ± 5 vs 15.9 ± 10 cm H2O, P < .001). The ventilation rate fell consistently within the guidelines, in the case of the automatic manually triggered device (EasyCPR) only (10.3 ± 2 vs 17.6 ± 6, P < .001). Significant pulmonary overdistention was observed when using the manual BVM device during the normal and obstructive sequences. The nurses and paramedics considered the ergonomics of the automatic manually triggered device (EasyCPR) to be better than those of the manual device. The use of an automatic manually triggered device may improve ventilation efficiency and decrease the risk of

  14. Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey

    Science.gov (United States)

    Arbogast, Belinda F.

    1996-01-01

    The analytical methods validated by the Mineral Resource Surveys Program, Geologic Division, is the subject of this manual. This edition replaces the methods portion of Open-File Report 90-668 published in 1990. Newer methods may be used which have been approved by the quality assurance (QA) project and are on file with the QA coordinator.This manual is intended primarily for use by laboratory scientists; this manual can also assist laboratory users to evaluate the data they receive. The analytical methods are written in a step by step approach so that they may be used as a training tool and provide detailed documentation of the procedures for quality assurance. A "Catalog of Services" is available for customer (submitter) use with brief listings of:the element(s)/species determined,method of determination,reference to cite,contact person,summary of the technique,and analyte concentration range.For a copy please contact the Branch office at (303) 236-1800 or fax (303) 236-3200.

  15. Fuel Element Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Burley, H.H. [ed.

    1956-08-01

    It is the purpose of the Fuel Element Technical Manual to Provide a single document describing the fabrication processes used in the manufacture of the fuel element as well as the technical bases for these processes. The manual will be instrumental in the indoctrination of personnel new to the field and will provide a single data reference for all personnel involved in the design or manufacture of the fuel element. The material contained in this manual was assembled by members of the Engineering Department and the Manufacturing Department at the Hanford Atomic Products Operation between the dates October, 1955 and June, 1956. Arrangement of the manual. The manual is divided into six parts: Part I--introduction; Part II--technical bases; Part III--process; Part IV--plant and equipment; Part V--process control and improvement; and VI--safety.

  16. Development and Validation of the Personality Assessment Questionnaire: Test Manual.

    Science.gov (United States)

    Rohner, Ronald P.; And Others

    Data are presented evaluating the validity and reliability of the Personality Assessment Questionnaire (PAQ), a self-report questionnaire designed to elicit respondents' perceptions of themselves with respect to seven personality and behavioral dispositions: hostility and aggression, dependence, self-esteem, self-adequacy, emotional…

  17. The Model Confidence Set

    DEFF Research Database (Denmark)

    Hansen, Peter Reinhard; Lunde, Asger; Nason, James M.

    The paper introduces the model confidence set (MCS) and applies it to the selection of models. A MCS is a set of models that is constructed such that it will contain the best model with a given level of confidence. The MCS is in this sense analogous to a confidence interval for a parameter. The MCS......, beyond the comparison of models. We apply the MCS procedure to two empirical problems. First, we revisit the inflation forecasting problem posed by Stock and Watson (1999), and compute the MCS for their set of inflation forecasts. Second, we compare a number of Taylor rule regressions and determine...... the MCS of the best in terms of in-sample likelihood criteria....

  18. The confidence in diabetes self-care scale

    DEFF Research Database (Denmark)

    Van Der Ven, Nicole C W; Weinger, Katie; Yi, Joyce

    2003-01-01

    evaluated in Dutch (n = 151) and U.S. (n = 190) outpatients with type 1 diabetes. In addition to the CIDS scale, assessment included HbA(1c), emotional distress, fear of hypoglycemia, self-esteem, anxiety, depression, and self-care behavior. The Dutch sample completed additional measures on perceived burden......OBJECTIVE: To examine psychometric properties of the Confidence in Diabetes Self-Care (CIDS) scale, a newly developed instrument assessing diabetes-specific self-efficacy in Dutch and U.S. patients with type 1 diabetes. RESEARCH DESIGN AND METHODS: Reliability and validity of the CIDS scale were...... and importance of self-care. Test-retest reliability was established in a second Dutch sample (n = 62). RESULTS: Internal consistency (Cronbach's alpha = 0.86 for Dutch patients and 0.90 U.S. patients) and test-retest reliability (Spearman's r = 0.85, P

  19. Comparison of Rice Direct Seeding Methods (Mechanical and Manual with Transplanting Method

    Directory of Open Access Journals (Sweden)

    A Eyvani

    2014-04-01

    Full Text Available The main method of rice planting in Iran is transplanting. Due to poor mechanization of rice production, this method is laborious and costly. The other method is direct seeding in wet lands which is performed in the one third of rice cultivation area of the world. The most important problem in this method is high labor requirement of weed control. In order to compare the different rice planting methods (direct drilling, transplanting, and seed broadcasting a manually operated rice direct seeder (drum seeder was designed and fabricated. The research was conducted using a randomized complete block design with three treatments and three replications. Required draft force, field efficiency, effective field capacity, yield, and yield components were measured and the treatments were compared economically. Results showed that there were significant differences among the treatments from the view point of rice yield at the confidence level of 95% i.e. the transplanting method had the maximum yield. A higher rice yield was obtained from the direct seeder compared to the manual broadcasting method but, the difference between these two methods for crop yield was not significant even at the confidence level of the 95%. The coefficient of variation of seed distribution with direct seeding was more than 20%. The labor and time requirements per hectare reduced to 7 and 20 times, respectively when comparing the newly designed direct seeder with the transplanting method. The direct seeding method had the highest benefit to cost ratio in spite of its lower yield. Therefore, this method could be recommended in the rice growing regions.

  20. Radiological control manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPP and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP.

  1. Radiological control manual. Revision 1

    International Nuclear Information System (INIS)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPP and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP

  2. CRISP instrument manual

    International Nuclear Information System (INIS)

    Bucknall, D.G.; Langridge, Sean

    1997-05-01

    This document is a user manual for CRISP, one of the two neutron reflectomers at ISIS. CRISP is highly automated allowing precision reproducible measurements. The manual provides detailed instructions for the setting-up and running of the instrument and advice on data analysis. (UK)

  3. Salinas : theory manual.

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Timothy Francis; Reese, Garth M.; Bhardwaj, Manoj Kumar

    2004-08-01

    This manual describes the theory behind many of the constructs in Salinas. For a more detailed description of how to use Salinas , we refer the reader to Salinas, User's Notes. Many of the constructs in Salinas are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Salinas are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programer-notes manual, the user's notes and of course the material in the open literature.

  4. PCs The Missing Manual

    CERN Document Server

    Karp, David

    2005-01-01

    Your vacuum comes with one. Even your blender comes with one. But your PC--something that costs a whole lot more and is likely to be used daily and for tasks of far greater importance and complexity--doesn't come with a printed manual. Thankfully, that's not a problem any longer: PCs: The Missing Manual explains everything you need to know about PCs, both inside and out, and how to keep them running smoothly and working the way you want them to work. A complete PC manual for both beginners and power users, PCs: The Missing Manual has something for everyone. PC novices will appreciate the una

  5. ATHLET. Mod 3.0 Cycle A. Validation

    Energy Technology Data Exchange (ETDEWEB)

    Lerchl, G.; Austregesilo, H.; Glaeser, H.; Hrubisko, M.; Luther, W.

    2012-09-15

    ATHLET is an advanced best-estimate code which has been initially developed for the simulation of design basis and beyond design basis accidents (without core degradation) in light water reactors, including VVER and RBMK reactors. Furthermore, this program version enables the simulation of further working fluids like helium and liquid metals. The one-dimensional, two-phase fluiddynamic models are based on a five-equation model supplemented by a full-range drift-flux model, including a dynamic mixture-level tracking capability. Moreover, a two-fluid model based on six conservation equations is provided. The heat conduction and heat transfer module allows a flexible simulation of fuel rods and structures. The nuclear heat generation is calculated by a point-kinetics or by a one-dimensional kinetics model. A general control simulation module is provided for a flexible modelling of BOP- and auxiliary plant systems. Systematic code validation is performed by GRS and independent organizations. This Validation Manual is the fourth volume of the ATHLET Code Documentation comprising four volumes. This manual presents an overview about the complete ATHLET validation effort spent up to now. In addition, the results of five test cases simulated with the present ATHLET program version are compared with the experimental data.

  6. Level of Self-confidence among Female Students of Hail University in Saudi Arabia in Relationship with some Variables

    Directory of Open Access Journals (Sweden)

    Wedad Mohammad Saleh Alkferi

    2017-11-01

    Full Text Available This study aimed to detect the level of self-confidence among female students of Hail University, and whether there were significant differences at the level of the students' self-confidence attributed to the variables of age and specialization. The study sample, which was randomly selected, consisted of 802 students from various disciplines at the university (medicine, engineering, psychology, and Islamic culture enrolled for the second semester of the academic year (2015/2016. To achieve the objectives of the study a confidence Scale developed by Kawasmeh and Farah (1996. The scale was checked for its validity and reliability. The statistical package SPSS was used to extract the results. Results of the study revealed a low level of self-confidence for the students of the university, whereas there were no statistically significant differences due to the variables of age and specialization. Keywords: Self-confidence, Students of Hail University, Saudi Arabia, Some variables.

  7. Automated forms processing - An alternative to time-consuming manual double entry of data in arthroplasty registries?

    DEFF Research Database (Denmark)

    Paulsen, Aksel

    2012-01-01

    , there was no statistical difference compared to single-key data entry (error proportion=0.007 (95% CI: 0.001-0.024), (p= 0.656)), as well as double-key data entry (error proportion=0.003 (95% CI: 0.000-0.019), (p= 0.319)). Discussion and conclusion: Automated forms processing is a valid alternative to double manual data......Background: The clinical and scientific usage of patient-reported outcome measures is increasing in the health services. Often paper forms are used. Manual double entry of data is defined as the definitive gold standard for transferring data to an electronic format, but the process is laborious....... Automated forms processing may be an alternative, but further validation is warranted. Materials and Methods: 200 patients were randomly selected from a cohort of 5777 patients who had previously answered two different questionnaires. The questionnaires were scanned using an automated forms processing...

  8. Integration of multiple biological features yields high confidence human protein interactome.

    Science.gov (United States)

    Karagoz, Kubra; Sevimoglu, Tuba; Arga, Kazim Yalcin

    2016-08-21

    The biological function of a protein is usually determined by its physical interaction with other proteins. Protein-protein interactions (PPIs) are identified through various experimental methods and are stored in curated databases. The noisiness of the existing PPI data is evident, and it is essential that a more reliable data is generated. Furthermore, the selection of a set of PPIs at different confidence levels might be necessary for many studies. Although different methodologies were introduced to evaluate the confidence scores for binary interactions, a highly reliable, almost complete PPI network of Homo sapiens is not proposed yet. The quality and coverage of human protein interactome need to be improved to be used in various disciplines, especially in biomedicine. In the present work, we propose an unsupervised statistical approach to assign confidence scores to PPIs of H. sapiens. To achieve this goal PPI data from six different databases were collected and a total of 295,288 non-redundant interactions between 15,950 proteins were acquired. The present scoring system included the context information that was assigned to PPIs derived from eight biological attributes. A high confidence network, which included 147,923 binary interactions between 13,213 proteins, had scores greater than the cutoff value of 0.80, for which sensitivity, specificity, and coverage were 94.5%, 80.9%, and 82.8%, respectively. We compared the present scoring method with others for evaluation. Reducing the noise inherent in experimental PPIs via our scoring scheme increased the accuracy significantly. As it was demonstrated through the assessment of process and cancer subnetworks, this study allows researchers to construct and analyze context-specific networks via valid PPI sets and one can easily achieve subnetworks around proteins of interest at a specified confidence level. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. The EADC-ADNI Harmonized Protocol for manual hippocampal segmentation on magnetic resonance: Evidence of validity

    Science.gov (United States)

    Frisoni, Giovanni B.; Jack, Clifford R.; Bocchetta, Martina; Bauer, Corinna; Frederiksen, Kristian S.; Liu, Yawu; Preboske, Gregory; Swihart, Tim; Blair, Melanie; Cavedo, Enrica; Grothe, Michel J.; Lanfredi, Mariangela; Martinez, Oliver; Nishikawa, Masami; Portegies, Marileen; Stoub, Travis; Ward, Chadwich; Apostolova, Liana G.; Ganzola, Rossana; Wolf, Dominik; Barkhof, Frederik; Bartzokis, George; DeCarli, Charles; Csernansky, John G.; deToledo-Morrell, Leyla; Geerlings, Mirjam I.; Kaye, Jeffrey; Killiany, Ronald J.; Lehéricy, Stephane; Matsuda, Hiroshi; O'Brien, John; Silbert, Lisa C.; Scheltens, Philip; Soininen, Hilkka; Teipel, Stefan; Waldemar, Gunhild; Fellgiebel, Andreas; Barnes, Josephine; Firbank, Michael; Gerritsen, Lotte; Henneman, Wouter; Malykhin, Nikolai; Pruessner, Jens C.; Wang, Lei; Watson, Craig; Wolf, Henrike; deLeon, Mony; Pantel, Johannes; Ferrari, Clarissa; Bosco, Paolo; Pasqualetti, Patrizio; Duchesne, Simon; Duvernoy, Henri; Boccardi, Marina

    2015-01-01

    Background An international Delphi panel has defined a harmonized protocol (HarP) for the manual segmentation of the hippocampus on MR. The aim of this study is to study the concurrent validity of the HarP toward local protocols, and its major sources of variance. Methods Fourteen tracers segmented 10 Alzheimer's Disease Neuroimaging Initiative (ADNI) cases scanned at 1.5 T and 3T following local protocols, qualified for segmentation based on the HarP through a standard web-platform and resegmented following the HarP. The five most accurate tracers followed the HarP to segment 15 ADNI cases acquired at three time points on both 1.5 T and 3T. Results The agreement among tracers was relatively low with the local protocols (absolute left/right ICC 0.44/0.43) and much higher with the HarP (absolute left/right ICC 0.88/0.89). On the larger set of 15 cases, the HarP agreement within (left/right ICC range: 0.94/0.95 to 0.99/0.99) and among tracers (left/right ICC range: 0.89/0.90) was very high. The volume variance due to different tracers was 0.9% of the total, comparing favorably to variance due to scanner manufacturer (1.2), atrophy rates (3.5), hemispheric asymmetry (3.7), field strength (4.4), and significantly smaller than the variance due to atrophy (33.5%, P < .001), and physiological variability (49.2%, P < .001). Conclusions The HarP has high measurement stability compared with local segmentation protocols, and good reproducibility within and among human tracers. Hippocampi segmented with the HarP can be used as a reference for the qualification of human tracers and automated segmentation algorithms. PMID:25267715

  10. Validation of geotechnical software for repository performance assessment

    International Nuclear Information System (INIS)

    LeGore, T.; Hoover, J.D.; Khaleel, R.; Thornton, E.C.; Anantatmula, R.P.; Lanigan, D.C.

    1989-01-01

    An important step in the characterization of a high level nuclear waste repository is to demonstrate that geotechnical software, used in performance assessment, correctly models validation. There is another type of validation, called software validation. It is based on meeting the requirements of specifications documents (e.g. IEEE specifications) and does not directly address the correctness of the specifications. The process of comparing physical experimental results with the predicted results should incorporate an objective measure of the level of confidence regarding correctness. This paper reports on a methodology developed that allows the experimental uncertainties to be explicitly included in the comparison process. The methodology also allows objective confidence levels to be associated with the software. In the event of a poor comparison, the method also lays the foundation for improving the software

  11. Confidence in critical care nursing.

    Science.gov (United States)

    Evans, Jeanne; Bell, Jennifer L; Sweeney, Annemarie E; Morgan, Jennifer I; Kelly, Helen M

    2010-10-01

    The purpose of the study was to gain an understanding of the nursing phenomenon, confidence, from the experience of nurses in the nursing subculture of critical care. Leininger's theory of cultural care diversity and universality guided this qualitative descriptive study. Questions derived from the sunrise model were used to elicit nurses' perspectives about cultural and social structures that exist within the critical care nursing subculture and the influence that these factors have on confidence. Twenty-eight critical care nurses from a large Canadian healthcare organization participated in semistructured interviews about confidence. Five themes arose from the descriptions provided by the participants. The three themes, tenuously navigating initiation rituals, deliberately developing holistic supportive relationships, and assimilating clinical decision-making rules were identified as social and cultural factors related to confidence. The remaining two themes, preserving a sense of security despite barriers and accommodating to diverse challenges, were identified as environmental factors related to confidence. Practice and research implications within the culture of critical care nursing are discussed in relation to each of the themes.

  12. Professional confidence: a concept analysis.

    Science.gov (United States)

    Holland, Kathlyn; Middleton, Lyn; Uys, Leana

    2012-03-01

    Professional confidence is a concept that is frequently used and or implied in occupational therapy literature, but often without specifying its meaning. Rodgers's Model of Concept Analysis was used to analyse the term "professional confidence". Published research obtained from a federated search in four health sciences databases was used to inform the concept analysis. The definitions, attributes, antecedents, and consequences of professional confidence as evidenced in the literature are discussed. Surrogate terms and related concepts are identified, and a model case of the concept provided. Based on the analysis, professional confidence can be described as a dynamic, maturing personal belief held by a professional or student. This includes an understanding of and a belief in the role, scope of practice, and significance of the profession, and is based on their capacity to competently fulfil these expectations, fostered through a process of affirming experiences. Developing and fostering professional confidence should be nurtured and valued to the same extent as professional competence, as the former underpins the latter, and both are linked to professional identity.

  13. The Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Folley, G.; Pearson, L.; Crosby, C. [Alaska Dept. of Environmental Conservation, Soldotna, AK (United States); DeCola, E.; Robertson, T. [Nuka Research and Planning Group, Seldovia, AK (United States)

    2006-07-01

    A comprehensive water quality sampling program was conducted in response to the oil spill that occurred when the M/V Selendang Ayu ship ran aground near a major fishing port at Unalaska Island, Alaska in December 2004. In particular, the sampling program focused on the threat of spilled oil to the local commercial fisheries resources. Spill scientists were unable to confidently model the movement of oil away from the wreck because of limited oceanographic data. In order to determine which fish species were at risk of oil contamination, a real-time assessment of how and where the oil was moving was needed, because the wreck became a continual source of oil release for several weeks after the initial grounding. The newly developed methods and procedures used to detect whole oil during the sampling program will be presented in the Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual which is currently under development. The purpose of the manual is to provide instructions to spill managers while they try to determine where spilled oil has or has not been encountered. The manual will include a meaningful data set that can be analyzed in real time to assess oil movement and concentration. Sections on oil properties and processes will be included along with scientific water quality sampling methods for whole and dissolved phase oil to assess potential contamination of commercial fishery resources and gear in Alaska waters during an oil spill. The manual will present a general discussion of factors that should be considered when designing a sampling program after a spill. In order to implement Alaska's improved seafood safety measures, the spatial scope of spilled oil must be known. A water quality sampling program can provide state and federal fishery managers and food safety inspectors with important information as they identify at-risk fisheries. 11 refs., 7 figs.

  14. The discriminant (and convergent) validity of the Personality Inventory for DSM-5.

    Science.gov (United States)

    Crego, Cristina; Gore, Whitney L; Rojas, Stephanie L; Widiger, Thomas A

    2015-10-01

    A considerable body of research has rapidly accumulated with respect to the validity of the Diagnostic and Statistical Manual of Mental Disorders (5th ed.; DSM-5) dimensional trait model as it is assessed by the Personality Inventory for Diagnostic and Statistical Manual of Mental Disorders (PID-5; Krueger et al., 2012). This research though has not focused specifically on discriminant validity, although allusions to potentially problematic discriminant validity have been raised. The current study addressed discriminant validity, reporting for the first time the correlations among the PID-5 domain scales. Also reported are the bivariate correlations of the 25 PID-5 maladaptive trait scales with the personality domain scales of the NEO Personality Inventory-Revised (Costa & McCrae, 1992), the International Personality Item Pool-NEO (Goldberg et al., 2006), the Inventory of Personal Characteristics (Almagor et al., 1995), the 5-Dimensional Personality Test (van Kampen, 2012), and the HEXACO Personality Inventory-Revised (Lee & Ashton, 2004). The results are discussed with respect to the implications of and alternative explanations for potentially problematic discriminant validity. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  15. Are multiple-trial experiments appropriate for eyewitness identification studies? Accuracy, choosing, and confidence across trials.

    Science.gov (United States)

    Mansour, J K; Beaudry, J L; Lindsay, R C L

    2017-12-01

    Eyewitness identification experiments typically involve a single trial: A participant views an event and subsequently makes a lineup decision. As compared to this single-trial paradigm, multiple-trial designs are more efficient, but significantly reduce ecological validity and may affect the strategies that participants use to make lineup decisions. We examined the effects of a number of forensically relevant variables (i.e., memory strength, type of disguise, degree of disguise, and lineup type) on eyewitness accuracy, choosing, and confidence across 12 target-present and 12 target-absent lineup trials (N = 349; 8,376 lineup decisions). The rates of correct rejections and choosing (across both target-present and target-absent lineups) did not vary across the 24 trials, as reflected by main effects or interactions with trial number. Trial number had a significant but trivial quadratic effect on correct identifications (OR = 0.99) and interacted significantly, but again trivially, with disguise type (OR = 1.00). Trial number did not significantly influence participants' confidence in correct identifications, confidence in correct rejections, or confidence in target-absent selections. Thus, multiple-trial designs appear to have minimal effects on eyewitness accuracy, choosing, and confidence. Researchers should thus consider using multiple-trial designs for conducting eyewitness identification experiments.

  16. Eco-Innovation Manual

    DEFF Research Database (Denmark)

    O'Hare, Jamie Alexander; McAloone, Tim C.; Pigosso, Daniela Cristina Antelmi

    Aim of this manual is to introduce a methodology for the implementation of eco‐innovation within small and medium sized companies in developing and emerging economies. The intended audience of this manual is organizations that provide professional services to guide and support manufacturing compa...... companies to improve their sustainability performance....

  17. Regional Competition for Confidence: Features of Formation

    Directory of Open Access Journals (Sweden)

    Irina Svyatoslavovna Vazhenina

    2016-09-01

    Full Text Available The increase in economic independence of the regions inevitably leads to an increase in the quality requirements of the regional economic policy. The key to successful regional policy, both during its development and implementation, is the understanding of the necessity of gaining confidence (at all levels, and the inevitable participation in the competition for confidence. The importance of confidence in the region is determined by its value as a competitive advantage in the struggle for partners, resources and tourists, and attracting investments. In today’s environment the focus of governments, regions and companies on long-term cooperation is clearly expressed, which is impossible without a high level of confidence between partners. Therefore, the most important competitive advantages of territories are intangible assets such as an attractive image and a good reputation, which builds up confidence of the population and partners. The higher the confidence in the region is, the broader is the range of potential partners, the larger is the planning horizon of long-term concerted action, the better are the chances of acquiring investment, the higher is the level of competitive immunity of the territories. The article defines competition for confidence as purposeful behavior of a market participant in economic environment, aimed at acquiring specific intangible competitive advantage – the confidence of the largest possible number of other market actors. The article also highlights the specifics of confidence as a competitive goal, presents factors contributing to the destruction of confidence, proposes a strategy to fight for confidence as a program of four steps, considers the factors which integrate regional confidence and offers several recommendations for the establishment of effective regional competition for confidence

  18. FINAS. Example manual. 2

    International Nuclear Information System (INIS)

    Iwata, Koji; Tsukimori, Kazuyuki; Ueno, Mutsuo

    2003-12-01

    FINAS is a general purpose structural analysis computer program which was developed by Japan Nuclear Cycle Development Institute for the analysis of static, dynamic and thermal responses of elastic and inelastic structures by the finite element method. This manual contains typical analysis examples that illustrate applications of FINAS to a variety of structural engineering problems. The first part of this manual presents fundamental examples in which numerical solutions by FINAS are compared with some analytical reference solutions, and the second part of this manual presents more complex examples intended for practical application. All the input data images and principal results for each problem are included in this manual for beginners' convenience. All the analyses are performed by using the FINAS Version 13.0. (author)

  19. A multisite validation of whole slide imaging for primary diagnosis using standardized data collection and analysis.

    Science.gov (United States)

    Wack, Katy; Drogowski, Laura; Treloar, Murray; Evans, Andrew; Ho, Jonhan; Parwani, Anil; Montalto, Michael C

    2016-01-01

    Text-based reporting and manual arbitration for whole slide imaging (WSI) validation studies are labor intensive and do not allow for consistent, scalable, and repeatable data collection or analysis. The objective of this study was to establish a method of data capture and analysis using standardized codified checklists and predetermined synoptic discordance tables and to use these methods in a pilot multisite validation study. Fifteen case report form checklists were generated from the College of American Pathology cancer protocols. Prior to data collection, all hypothetical pairwise comparisons were generated, and a level of harm was determined for each possible discordance. Four sites with four pathologists each generated 264 independent reads of 33 cases. Preestablished discordance tables were applied to determine site by site and pooled accuracy, intrareader/intramodality, and interreader intramodality error rates. Over 10,000 hypothetical pairwise comparisons were evaluated and assigned harm in discordance tables. The average difference in error rates between WSI and glass, as compared to ground truth, was 0.75% with a lower bound of 3.23% (95% confidence interval). Major discordances occurred on challenging cases, regardless of modality. The average inter-reader agreement across sites for glass was 76.5% (weighted kappa of 0.68) and for digital it was 79.1% (weighted kappa of 0.72). These results demonstrate the feasibility and utility of employing standardized synoptic checklists and predetermined discordance tables to gather consistent, comprehensive diagnostic data for WSI validation studies. This method of data capture and analysis can be applied in large-scale multisite WSI validations.

  20. Biosafety Manual

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce W.

    2010-05-18

    Work with or potential exposure to biological materials in the course of performing research or other work activities at Lawrence Berkeley National Laboratory (LBNL) must be conducted in a safe, ethical, environmentally sound, and compliant manner. Work must be conducted in accordance with established biosafety standards, the principles and functions of Integrated Safety Management (ISM), this Biosafety Manual, Chapter 26 (Biosafety) of the Health and Safety Manual (PUB-3000), and applicable standards and LBNL policies. The purpose of the Biosafety Program is to protect workers, the public, agriculture, and the environment from exposure to biological agents or materials that may cause disease or other detrimental effects in humans, animals, or plants. This manual provides workers; line management; Environment, Health, and Safety (EH&S) Division staff; Institutional Biosafety Committee (IBC) members; and others with a comprehensive overview of biosafety principles, requirements from biosafety standards, and measures needed to control biological risks in work activities and facilities at LBNL.

  1. Automated Liquibase Generator And ValidatorALGV

    Directory of Open Access Journals (Sweden)

    Manik Jain

    2015-08-01

    Full Text Available Abstract This paper presents an automation tool namely ALGV Automated Liquibase Generator and Validator for the automated generation and verification of liquibase scripts. Liquibase is one of the most efficient ways of applying and persisting changes to a database schema. Since its invention by Nathan Voxland 1 it has become de facto standard for database change management. The advantages of using liquibase scripts over traditional sql queries ranges from version control to reusing the same scripts over multiple database platforms. Irrespective of its advantages manual creation of liquibase scripts takes a lot of effort and sometimes is error-prone. ALGV helps to reduce the time consuming liquibase script generation manual typing efforts possible error occurrence and manual verification process and time by 75. Automating the liquibase generation process also helps to remove the burden of recollecting specific tags to be used for a particular change. Moreover developers can concentrate on the business logic and business data rather than wasting their precious efforts in writing files.

  2. Regional Test Center Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Burnham, Laurie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    The U.S. DOE Regional Test Center for Solar Technologies program was established to validate photovoltaic (PV) technologies installed in a range of different climates. The program is funded by the Energy Department's SunShot Initiative. The initiative seeks to make solar energy cost competitive with other forms of electricity by the end of the decade. Sandia National Laboratory currently manages four different sites across the country. The National Renewable Energy Laboratory manages a fifth site in Colorado. The entire PV portfolio currently includes 20 industry partners and almost 500 kW of installed systems. The program follows a defined process that outlines tasks, milestones, agreements, and deliverables. The process is broken out into four main parts: 1) planning and design, 2) installation, 3) operations, and 4) decommissioning. This operations manual defines the various elements of each part.

  3. Automatic segmentation of myocardium at risk from contrast enhanced SSFP CMR: validation against expert readers and SPECT

    International Nuclear Information System (INIS)

    Tufvesson, Jane; Carlsson, Marcus; Aletras, Anthony H.; Engblom, Henrik; Deux, Jean-François; Koul, Sasha; Sörensson, Peder; Pernow, John; Atar, Dan; Erlinge, David; Arheden, Håkan; Heiberg, Einar

    2016-01-01

    Efficacy of reperfusion therapy can be assessed as myocardial salvage index (MSI) by determining the size of myocardium at risk (MaR) and myocardial infarction (MI), (MSI = 1-MI/MaR). Cardiovascular magnetic resonance (CMR) can be used to assess MI by late gadolinium enhancement (LGE) and MaR by either T2-weighted imaging or contrast enhanced SSFP (CE-SSFP). Automatic segmentation algorithms have been developed and validated for MI by LGE as well as for MaR by T2-weighted imaging. There are, however, no algorithms available for CE-SSFP. Therefore, the aim of this study was to develop and validate automatic segmentation of MaR in CE-SSFP. The automatic algorithm applies surface coil intensity correction and classifies myocardial intensities by Expectation Maximization to define a MaR region based on a priori regional criteria, and infarct region from LGE. Automatic segmentation was validated against manual delineation by expert readers in 183 patients with reperfused acute MI from two multi-center randomized clinical trials (RCT) (CHILL-MI and MITOCARE) and against myocardial perfusion SPECT in an additional set (n = 16). Endocardial and epicardial borders were manually delineated at end-diastole and end-systole. Manual delineation of MaR was used as reference and inter-observer variability was assessed for both manual delineation and automatic segmentation of MaR in a subset of patients (n = 15). MaR was expressed as percent of left ventricular mass (%LVM) and analyzed by bias (mean ± standard deviation). Regional agreement was analyzed by Dice Similarity Coefficient (DSC) (mean ± standard deviation). MaR assessed by manual and automatic segmentation were 36 ± 10 % and 37 ± 11 %LVM respectively with bias 1 ± 6 %LVM and regional agreement DSC 0.85 ± 0.08 (n = 183). MaR assessed by SPECT and CE-SSFP automatic segmentation were 27 ± 10 %LVM and 29 ± 7 %LVM respectively with bias 2 ± 7 %LVM. Inter-observer variability was 0 ± 3 %LVM for manual delineation and

  4. ACT Plan: Technical Manual. 2013/2014

    Science.gov (United States)

    ACT, Inc., 2013

    2013-01-01

    This manual contains information about the American College Test (ACT) Plan® program. The principal focus of this manual is to document the Plan program's technical adequacy in light of its intended purposes. This manual supersedes the 2011 edition. The content of this manual responds to requirements of the testing industry as established in the…

  5. COMPARISON OF MANUAL AND SEMIAUTOMATED FUNDUS AUTOFLUORESCENCE ANALYSIS OF MACULAR ATROPHY IN STARGARDT DISEASE PHENOTYPE.

    Science.gov (United States)

    Kuehlewein, Laura; Hariri, Amir H; Ho, Alexander; Dustin, Laurie; Wolfson, Yulia; Strauss, Rupert W; Scholl, Hendrik P N; Sadda, SriniVas R

    2016-06-01

    To evaluate manual and semiautomated grading techniques for assessing decreased fundus autofluorescence (DAF) in patients with Stargardt disease phenotype. Certified reading center graders performed manual and semiautomated (region finder-based) grading of confocal scanning laser ophthalmoscopy (cSLO) fundus autofluorescence (FAF) images for 41 eyes of 22 patients. Lesion types were defined based on the black level and sharpness of the border: definite decreased autofluorescence (DDAF), well, and poorly demarcated questionably decreased autofluorescence (WDQDAF, PDQDAF). Agreement in grading between the two methods and inter- and intra-grader agreement was assessed by kappa coefficients (κ) and intraclass correlation coefficients (ICC). The mean ± standard deviation (SD) area was 3.07 ± 3.02 mm for DDAF (n = 31), 1.53 ± 1.52 mm for WDQDAF (n = 9), and 6.94 ± 10.06 mm for PDQDAF (n = 17). The mean ± SD absolute difference in area between manual and semiautomated grading was 0.26 ± 0.28 mm for DDAF, 0.20 ± 0.26 mm for WDQDAF, and 4.05 ± 8.32 mm for PDQDAF. The ICC (95% confidence interval) for method comparison was 0.992 (0.984-0.996) for DDAF, 0.976 (0.922-0.993) for WDQDAF, and 0.648 (0.306-0.842) for PDQDAF. Inter- and intra-grader agreement in manual and semiautomated quantitative grading was better for DDAF (0.981-0.996) and WDQDAF (0.995-0.999) than for PDQDAF (0.715-0.993). Manual and semiautomated grading methods showed similar levels of reproducibility for assessing areas of decreased autofluorescence in patients with Stargardt disease phenotype. Excellent agreement and reproducibility were observed for well demarcated lesions.

  6. [Sources of leader's confidence in organizations].

    Science.gov (United States)

    Ikeda, Hiroshi; Furukawa, Hisataka

    2006-04-01

    The purpose of this study was to examine the sources of confidence that organization leaders had. As potential sources of the confidence, we focused on fulfillment of expectations made by self and others, reflection on good as well as bad job experiences, and awareness of job experiences in terms of commonality, differentiation, and multiple viewpoints. A questionnaire was administered to 170 managers of Japanese companies. Results were as follows: First, confidence in leaders was more strongly related to fulfillment of expectations made by self and others than reflection on and awareness of job experiences. Second, the confidence was weakly related to internal processing of job experiences, in the form of commonality awareness and reflection on good job experiences. And finally, years of managerial experiences had almost no relation to the confidence. These findings suggested that confidence in leaders was directly acquired from fulfillment of expectations made by self and others, rather than indirectly through internal processing of job experiences. Implications of the findings for leadership training were also discussed.

  7. Evaluation of a performance assessment methodology for low-level radioactive waste disposal facilities: Validation needs. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Kozak, M.W.; Olague, N.E. [Sandia National Labs., Albuquerque, NM (United States)

    1995-02-01

    In this report, concepts on how validation fits into the scheme of developing confidence in performance assessments are introduced. A general framework for validation and confidence building in regulatory decision making is provided. It is found that traditional validation studies have a very limited role in developing site-specific confidence in performance assessments. Indeed, validation studies are shown to have a role only in the context that their results can narrow the scope of initial investigations that should be considered in a performance assessment. In addition, validation needs for performance assessment of low-level waste disposal facilities are discussed, and potential approaches to address those needs are suggested. These areas of topical research are ranked in order of importance based on relevance to a performance assessment and likelihood of success.

  8. Evaluation of a performance assessment methodology for low-level radioactive waste disposal facilities: Validation needs. Volume 2

    International Nuclear Information System (INIS)

    Kozak, M.W.; Olague, N.E.

    1995-02-01

    In this report, concepts on how validation fits into the scheme of developing confidence in performance assessments are introduced. A general framework for validation and confidence building in regulatory decision making is provided. It is found that traditional validation studies have a very limited role in developing site-specific confidence in performance assessments. Indeed, validation studies are shown to have a role only in the context that their results can narrow the scope of initial investigations that should be considered in a performance assessment. In addition, validation needs for performance assessment of low-level waste disposal facilities are discussed, and potential approaches to address those needs are suggested. These areas of topical research are ranked in order of importance based on relevance to a performance assessment and likelihood of success

  9. Increasing Confidence and Ability in Implementing Kangaroo Mother Care Method Among Young Mothers.

    Science.gov (United States)

    Kenanga Purbasary, Eleni; Rustina, Yeni; Budiarti, Tri

    Mothers giving birth to low birth weight babies (LBWBs) have low confidence in caring for their babies because they are often still young and may lack the knowledge, experience, and ability to care for the baby. This research aims to determine the effect of education about kangaroo mother care (KMC) on the confidence and ability of young mothers to implement KMC. The research methodology used was a controlled-random experimental approach with pre- and post-test equivalent groups of 13 mothers and their LBWBs in the intervention group and 13 mothers and their LBWBs in the control group. Data were collected via an instrument measuring young mothers' confidence, the validity and reliability of which have been tested with a resulting r value of .941, and an observation sheet on KMC implementation. After conducting the education, the confidence score of young mothers and their ability to perform KMC increased meaningfully. The score of confidence of young mothers before education was 37 (p = .1555: and the ability score for KMC Implementation before education was 9 (p = .1555). The median score of confidence of young mothers after education in the intervention group was 87 and in the control group was 50 (p = .001, 95% CI 60.36-75.56), and ability median score for KMC implementation after education in the intervention group was 16 and in the control group was 12 (p = .001, 95% CI 1.50-1.88). KMC education should be conducted gradually, and it is necessary to involve the family, in order for KMC implementation to continue at home. A family visit can be done for LBWBs to evaluate the ability of the young mothers to implement KMC.

  10. Confidence-building and Canadian leadership

    International Nuclear Information System (INIS)

    Cleminson, F.R.

    1998-01-01

    Confidence-building has come into its own as a 'tool of choice' in facilitating the non-proliferation, arms control and disarmament (NACD) agenda, whether regional or global. From the Middle East Peace Process (MEPP) to the ASEAN Intersessional Group on Confidence-Building (ARF ISG on CBMS), confidence-building has assumed a central profile in regional terms. In the Four Power Talks begun in Geneva on December 9, 1997, the United States identified confidence-building as one of two subject areas for initial discussion as part of a structured peace process between North and South Korea. Thus, with CBMs assuming such a high profile internationally, it seems prudent for Canadians to pause and take stock of the significant role which Canada has already played in the conceptual development of the process over the last two decades. Since the Helsinki accords of 1975, Canada has developed a significant expertise in this area through an unbroken series of original, basic research projects. These have contributed to defining the process internationally from concept to implementation. Today, these studies represent a solid and unique Departmental investment in basic research from which to draw in meeting Canada's current commitments to multilateral initiatives in the area of confidence-building and to provide a 'step up' in terms of future-oriented leadership. (author)

  11. GRACE manual

    International Nuclear Information System (INIS)

    Ishikawa, T.; Kawabata, S.; Shimizu, Y.; Kaneko, T.; Kato, K.; Tanaka, H.

    1993-02-01

    This manual is composed of three kinds of objects, theoretical background for calculating the cross section of elementary process, usage and technical details of the GRACE system. Throughout this manual we take the tree level process e + e - → W + W - γ as an example, including the e ± -scalar boson interactions. The real FORTRAN source code for this process is attached in the relevant sections as well as the results of calculation, which might be a great help for understanding the practical use of the system. (J.P.N.)

  12. EML procedures manual

    International Nuclear Information System (INIS)

    Volchok, H.L.; de Planque, G.

    1982-01-01

    This manual contains the procedures that are used currently by the Environmental Measurements Laboratory of the US Department of Energy. In addition a number of analytical methods from other laboratories have been included. These were tested for reliability at the Battelle, Pacific Northwest Laboratory under contract with the Division of Biomedical and Environmental Research of the AEC. These methods are clearly distinguished. The manual is prepared in loose leaf form to facilitate revision of the procedures and inclusion of additional procedures or data sheets. Anyone receiving the manual through EML should receive this additional material automatically. The contents are as follows: (1) general; (2) sampling; (3) field measurements; (4) general analytical chemistry; (5) chemical procedures; (6) data section; (7) specifications

  13. Partners Plus: Families and Caregivers in Partnerships. A Family-Centered Guide to Respite Care. Trainer's Workshop Manual [and] Community Planning Manual [and] A Family Manual [and] Caregiver Manual.

    Science.gov (United States)

    Ownby, Lisa L.; Hooke, Amanda C.; Moore, Dee Wylie; Garland, Corinne W.; Frank, Adrienne

    Four manuals on implementing the Partners Respite Model, which provides respite care for children with disabilities or chronic illnesses, comprise this document. The Community Planning Manual offers a step-by-step guide to replication of the Partners Respite Model and is divided into sections on developing the Partners program, implementing the…

  14. The ISIS Open GENIE user manual

    International Nuclear Information System (INIS)

    Akeroyd, F.A.; Ashworth, R.L.; Campbell, S.I.; Johnston, S.D.; Martin, J.M.; Moreton-Smith, C.M.; Sivia, D.S.

    2000-01-01

    This manual should enable you to become familiar with Open GENIE quickly and easily. It therefore complements the Open GENIE Reference Manual which should be used to understand the full meaning of Open GENIE commands. The reference manual is accessible on the ISIS web server at: http://www.isis.rl.ac.uk/GENIEReferenceManual/ and the user manual is planned to be accessible by January '98 at http://www.isis.rl.ac.ukIGENIEUserManual/. The Open GENIE User Manual is separated into two parts: Part A. The User Manual. An introduction to the use of Open GENIE. Part B. The Installation Guide. General information on how to install and run Open GENIE. Assuming that you are new to Open GENIE and have just downloaded a copy you will need to consult the Installation Guide to get Open GENIE installed on your machine. After this we recommend you experiment with some of the example files to get an idea of the capabilities of Open GENIE. For further information, comments, additions of routines that you feel should be included, please contact us at genie at isise.rl.ac.uk

  15. The operation and maintenance manual

    International Nuclear Information System (INIS)

    Stoll, A.; Krotil, H.; Klein, W.

    1976-01-01

    The operating manual is one of many technical documents which the nuclear power plant operator needs for ensuring safe operation. For the operating staff, however, there is only one document, namely the operating manual. The operating manual is an essential element in bringing man and machine in harmony. This is necessary for safe and, as far as possible, uninterrupted operation of the power plant. The operating manual is the only document containing binding instructions for plant operation. All the tasks of plant operation which are carried out by plant staff are described in the operating manual in a form which is as clear and comprehensible as possible. A considerable number of these tasks can only be carried out by man, namely: 1) tasks concerning operational organization, 2) all non-automated areas of plant operation. (orig./TK) [de

  16. Extricating Manual and Non-Manual Features for Subunit Level Medical Sign Modelling in Automatic Sign Language Classification and Recognition.

    Science.gov (United States)

    R, Elakkiya; K, Selvamani

    2017-09-22

    Subunit segmenting and modelling in medical sign language is one of the important studies in linguistic-oriented and vision-based Sign Language Recognition (SLR). Many efforts were made in the precedent to focus the functional subunits from the view of linguistic syllables but the problem is implementing such subunit extraction using syllables is not feasible in real-world computer vision techniques. And also, the present recognition systems are designed in such a way that it can detect the signer dependent actions under restricted and laboratory conditions. This research paper aims at solving these two important issues (1) Subunit extraction and (2) Signer independent action on visual sign language recognition. Subunit extraction involved in the sequential and parallel breakdown of sign gestures without any prior knowledge on syllables and number of subunits. A novel Bayesian Parallel Hidden Markov Model (BPaHMM) is introduced for subunit extraction to combine the features of manual and non-manual parameters to yield better results in classification and recognition of signs. Signer independent action aims in using a single web camera for different signer behaviour patterns and for cross-signer validation. Experimental results have proved that the proposed signer independent subunit level modelling for sign language classification and recognition has shown improvement and variations when compared with other existing works.

  17. Fire Protection Program Manual

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, J A

    2012-05-18

    This manual documents the Lawrence Livermore National Laboratory (LLNL) Fire Protection Program. Department of Energy (DOE) Orders 420.1B, Facility Safety, requires LLNL to have a comprehensive and effective fire protection program that protects LLNL personnel and property, the public and the environment. The manual provides LLNL and its facilities with general information and guidance for meeting DOE 420.1B requirements. The recommended readers for this manual are: fire protection officers, fire protection engineers, fire fighters, facility managers, directorage assurance managers, facility coordinators, and ES and H team members.

  18. How do regulators measure public confidence?

    International Nuclear Information System (INIS)

    Schmitt, A.; Besenyei, E.

    2006-01-01

    The conclusions and recommendations of this session can be summarized this way. - There are some important elements of confidence: visibility, satisfaction, credibility and reputation. The latter can consist of trust, positive image and knowledge of the role the organisation plays. A good reputation is hard to achieve but easy to lose. - There is a need to define what public confidence is and what to measure. The difficulty is that confidence is a matter of perception of the public, so what we try to measure is the perception. - It is controversial how to take into account the results of confidence measurement because of the influence of the context. It is not an exact science, results should be examined cautiously and surveys should be conducted frequently, at least every two years. - Different experiences were explained: - Quantitative surveys - among the general public or more specific groups like the media; - Qualitative research - with test groups and small panels; - Semi-quantitative studies - among stakeholders who have regular contracts with the regulatory body. It is not clear if the results should be shared with the public or just with other authorities and governmental organisations. - Efforts are needed to increase visibility, which is a prerequisite for confidence. - A practical example of organizing an emergency exercise and an information campaign without taking into account the real concerns of the people was given to show how public confidence can be decreased. - We learned about a new method - the so-called socio-drama - which addresses another issue also connected to confidence - the notion of understanding between stakeholders around a nuclear site. It is another way of looking at confidence in a more restricted group. (authors)

  19. M3 User's Manual. Version 3.0

    International Nuclear Information System (INIS)

    Laaksoharju, Marcus; Skaarman, Erik; Gomez, Javier B.

    2009-11-01

    This report describes the Multivariate Mixing and Mass balance calculations (M3). This new method and computer code is developed to trace the mixing and reaction processes in the groundwater. The aim of the M3 concept is to decode the often hidden and complex information gathered in the groundwater analytical data. The manual presents shortly the theory and practice behind the M3 method. The M3 computer code is also presented and emphasis is put on the reference manual. This includes detailed reference to the M3 program's abilities and limitations, installation procedures and all functions and operations that the program can perform. It also describes sample cases of how the program is used to analyse a test data set. This guide is part of the Help Files distributed together with M3. Two accompanying reports cover other aspects: - Concepts, Methods, and Mathematical Formulation, gives a complete description of the mathematical framework of M3 and introduces concepts and methods useful for the end user. - M3 version 3.0: Verification and Validation, gathers a collection of validation and verification exercises, designed to test each part of M3 code and to build confidence in its methodology. The M3 method has been tested and modified over several years. The development work has been supported by the Swedish Nuclear Fuel and Waste Management Company (SKB). The main test site for the model was the underground Aespoe Hard Rock Laboratory (HRL). The examples used in this manual are from a Aespoe international groundwater modelling co-operation project where one of the tools used was M3. The M3 concept has been applied on the data from SKB's site investigation programme and in data from Canada, Japan, Jordan, Gabon and Finland. The groundwater composition is a result of mixing processes and water-rock interaction. Standard groundwater models based on thermodynamic laws may not be applicable in a normal temperature groundwater system where equilibrium with many of the

  20. An Investigation of Bilateral Symmetry During Manual Wheelchair Propulsion.

    Science.gov (United States)

    Soltau, Shelby L; Slowik, Jonathan S; Requejo, Philip S; Mulroy, Sara J; Neptune, Richard R

    2015-01-01

    Studies of manual wheelchair propulsion often assume bilateral symmetry to simplify data collection, processing, and analysis. However, the validity of this assumption is unclear. Most investigations of wheelchair propulsion symmetry have been limited by a relatively small sample size and a focus on a single propulsion condition (e.g., level propulsion at self-selected speed). The purpose of this study was to evaluate bilateral symmetry during manual wheelchair propulsion in a large group of subjects across different propulsion conditions. Three-dimensional kinematics and handrim kinetics along with spatiotemporal variables were collected and processed from 80 subjects with paraplegia while propelling their wheelchairs on a stationary ergometer during three different conditions: level propulsion at their self-selected speed (free), level propulsion at their fastest comfortable speed (fast), and propulsion on an 8% grade at their level, self-selected speed (graded). All kinematic variables had significant side-to-side differences, primarily in the graded condition. Push angle was the only spatiotemporal variable with a significant side-to-side difference, and only during the graded condition. No kinetic variables had significant side-to-side differences. The magnitudes of the kinematic differences were low, with only one difference exceeding 5°. With differences of such small magnitude, the bilateral symmetry assumption appears to be reasonable during manual wheelchair propulsion in subjects without significant upper-extremity pain or impairment. However, larger asymmetries may exist in individuals with secondary injuries and pain in their upper extremity and different etiologies of their neurological impairment.

  1. The Great Recession and confidence in homeownership

    OpenAIRE

    Anat Bracha; Julian Jamison

    2013-01-01

    Confidence in homeownership shifts for those who personally experienced real estate loss during the Great Recession. Older Americans are confident in the value of homeownership. Younger Americans are less confident.

  2. Automated bony region identification using artificial neural networks: reliability and validation measurements

    International Nuclear Information System (INIS)

    Gassman, Esther E.; Kallemeyn, Nicole A.; DeVries, Nicole A.; Shivanna, Kiran H.; Powell, Stephanie M.; Magnotta, Vincent A.; Ramme, Austin J.; Adams, Brian D.; Grosland, Nicole M.

    2008-01-01

    The objective was to develop tools for automating the identification of bony structures, to assess the reliability of this technique against manual raters, and to validate the resulting regions of interest against physical surface scans obtained from the same specimen. Artificial intelligence-based algorithms have been used for image segmentation, specifically artificial neural networks (ANNs). For this study, an ANN was created and trained to identify the phalanges of the human hand. The relative overlap between the ANN and a manual tracer was 0.87, 0.82, and 0.76, for the proximal, middle, and distal index phalanx bones respectively. Compared with the physical surface scans, the ANN-generated surface representations differed on average by 0.35 mm, 0.29 mm, and 0.40 mm for the proximal, middle, and distal phalanges respectively. Furthermore, the ANN proved to segment the structures in less than one-tenth of the time required by a manual rater. The ANN has proven to be a reliable and valid means of segmenting the phalanx bones from CT images. Employing automated methods such as the ANN for segmentation, eliminates the likelihood of rater drift and inter-rater variability. Automated methods also decrease the amount of time and manual effort required to extract the data of interest, thereby making the feasibility of patient-specific modeling a reality. (orig.)

  3. Automated bony region identification using artificial neural networks: reliability and validation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Gassman, Esther E.; Kallemeyn, Nicole A.; DeVries, Nicole A.; Shivanna, Kiran H. [The University of Iowa, Department of Biomedical Engineering, Seamans Center for the Engineering Arts and Sciences, Iowa City, IA (United States); The University of Iowa, Center for Computer-Aided Design, Iowa City, IA (United States); Powell, Stephanie M. [The University of Iowa, Department of Biomedical Engineering, Seamans Center for the Engineering Arts and Sciences, Iowa City, IA (United States); University of Iowa Hospitals and Clinics, The University of Iowa, Department of Radiology, Iowa City, IA (United States); Magnotta, Vincent A. [The University of Iowa, Department of Biomedical Engineering, Seamans Center for the Engineering Arts and Sciences, Iowa City, IA (United States); The University of Iowa, Center for Computer-Aided Design, Iowa City, IA (United States); University of Iowa Hospitals and Clinics, The University of Iowa, Department of Radiology, Iowa City, IA (United States); Ramme, Austin J. [University of Iowa Hospitals and Clinics, The University of Iowa, Department of Radiology, Iowa City, IA (United States); Adams, Brian D. [The University of Iowa, Department of Biomedical Engineering, Seamans Center for the Engineering Arts and Sciences, Iowa City, IA (United States); University of Iowa Hospitals and Clinics, The University of Iowa, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States); Grosland, Nicole M. [The University of Iowa, Department of Biomedical Engineering, Seamans Center for the Engineering Arts and Sciences, Iowa City, IA (United States); University of Iowa Hospitals and Clinics, The University of Iowa, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States); The University of Iowa, Center for Computer-Aided Design, Iowa City, IA (United States)

    2008-04-15

    The objective was to develop tools for automating the identification of bony structures, to assess the reliability of this technique against manual raters, and to validate the resulting regions of interest against physical surface scans obtained from the same specimen. Artificial intelligence-based algorithms have been used for image segmentation, specifically artificial neural networks (ANNs). For this study, an ANN was created and trained to identify the phalanges of the human hand. The relative overlap between the ANN and a manual tracer was 0.87, 0.82, and 0.76, for the proximal, middle, and distal index phalanx bones respectively. Compared with the physical surface scans, the ANN-generated surface representations differed on average by 0.35 mm, 0.29 mm, and 0.40 mm for the proximal, middle, and distal phalanges respectively. Furthermore, the ANN proved to segment the structures in less than one-tenth of the time required by a manual rater. The ANN has proven to be a reliable and valid means of segmenting the phalanx bones from CT images. Employing automated methods such as the ANN for segmentation, eliminates the likelihood of rater drift and inter-rater variability. Automated methods also decrease the amount of time and manual effort required to extract the data of interest, thereby making the feasibility of patient-specific modeling a reality. (orig.)

  4. ARS-Media for excel instruction manual

    Science.gov (United States)

    ARS-Media for Excel Instruction Manual is the instruction manual that explains how to use the Excel spreadsheet ARS-Media for Excel application. ARS-Media for Excel Instruction Manual is provided as a pdf file....

  5. MODIS Hotspot Validation over Thailand

    Directory of Open Access Journals (Sweden)

    Veerachai Tanpipat

    2009-11-01

    Full Text Available To ensure remote sensing MODIS hotspot (also known as active fire products or hotspots quality and precision in forest fire control and management in Thailand, an increased level of confidence is needed. Accuracy assessment of MODIS hotspots utilizing field survey data validation is described. A quantitative evaluation of MODIS hotspot products has been carried out since the 2007 forest fire season. The carefully chosen hotspots were scattered throughout the country and within the protected areas of the National Parks and Wildlife Sanctuaries. Three areas were selected as test sites for validation guidelines. Both ground and aerial field surveys were also conducted in this study by the Forest Fire Control Division, National Park, Wildlife and Plant Conversation Department, Ministry of Natural Resources and Environment, Thailand. High accuracy of 91.84 %, 95.60% and 97.53% for the 2007, 2008 and 2009 fire seasons were observed, resulting in increased confidence in the use of MODIS hotspots for forest fire control and management in Thailand.

  6. Confidence-building and Canadian leadership

    Energy Technology Data Exchange (ETDEWEB)

    Cleminson, F.R. [Dept. of Foreign Affairs and International Trade, Verification, Non-Proliferation, Arms Control and Disarmament Div (IDA), Ottawa, Ontario (Canada)

    1998-07-01

    Confidence-building has come into its own as a 'tool of choice' in facilitating the non-proliferation, arms control and disarmament (NACD) agenda, whether regional or global. From the Middle East Peace Process (MEPP) to the ASEAN Intersessional Group on Confidence-Building (ARF ISG on CBMS), confidence-building has assumed a central profile in regional terms. In the Four Power Talks begun in Geneva on December 9, 1997, the United States identified confidence-building as one of two subject areas for initial discussion as part of a structured peace process between North and South Korea. Thus, with CBMs assuming such a high profile internationally, it seems prudent for Canadians to pause and take stock of the significant role which Canada has already played in the conceptual development of the process over the last two decades. Since the Helsinki accords of 1975, Canada has developed a significant expertise in this area through an unbroken series of original, basic research projects. These have contributed to defining the process internationally from concept to implementation. Today, these studies represent a solid and unique Departmental investment in basic research from which to draw in meeting Canada's current commitments to multilateral initiatives in the area of confidence-building and to provide a 'step up' in terms of future-oriented leadership. (author)

  7. Shift Verification and Validation

    Energy Technology Data Exchange (ETDEWEB)

    Pandya, Tara M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Evans, Thomas M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Davidson, Gregory G [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Johnson, Seth R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Godfrey, Andrew T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-07

    This documentation outlines the verification and validation of Shift for the Consortium for Advanced Simulation of Light Water Reactors (CASL). Five main types of problems were used for validation: small criticality benchmark problems; full-core reactor benchmarks for light water reactors; fixed-source coupled neutron-photon dosimetry benchmarks; depletion/burnup benchmarks; and full-core reactor performance benchmarks. We compared Shift results to measured data and other simulated Monte Carlo radiation transport code results, and found very good agreement in a variety of comparison measures. These include prediction of critical eigenvalue, radial and axial pin power distributions, rod worth, leakage spectra, and nuclide inventories over a burn cycle. Based on this validation of Shift, we are confident in Shift to provide reference results for CASL benchmarking.

  8. Psychometric Properties of Persian Translated Version of Activities-specific Balance Confidence Scale (ABC in Arak Community-dwelling Older Adults

    Directory of Open Access Journals (Sweden)

    Daryoush Khajavi

    2017-11-01

    Full Text Available Abstract Background: Balance deficiency, falls and fear of fall are important problems that can resulted in reversed health outcomes including decreased quality of life. The purpose of this study was surveying factor structure, validation, and reliability determination of Persian translated version of Activities-specific Balance Confidence scale in community-dwelling older adults of Arak city. Materials and Methods: Research method was descriptive in form of psychometry. The statistic population was older adults of Arak in year 2012 and 308 subjects with mean age 69.38 years were selected availably. Data were collected by Persian translated version of Activities-specific Balance Confidence that is a 16-item scale and evaluates balance confidence in activities of daily living. Data were analyzed by Exploratory Factor Analysis. Test-retest and internal reliability were calculated by Pearson correlation coefficient and Chronbach’s Alpha. Data were analyzed with SPSS-16. Results: The findings resulted in extraction of one factor with eigenvalue over one that explained 82.89% of total variance. Test-retest reliability between 1 to 4 weeks and internal reliability (Chronbach’s alpha were 0.82 and 0.98, respectively. Gutmann split-half correlation coefficient and intra-class correlation coefficient were calculated 95% and 85%, respectively. Conclusion: Persian translated version of Activities-specific Balance Confidence (ABC-F is a valid and reliable tool for Iranian community-dwelling older adults that can be used in clinical and research purpose.

  9. The development and validation of measures to assess cooking skills and food skills.

    Science.gov (United States)

    Lavelle, Fiona; McGowan, Laura; Hollywood, Lynsey; Surgenor, Dawn; McCloat, Amanda; Mooney, Elaine; Caraher, Martin; Raats, Monique; Dean, Moira

    2017-09-02

    With the increase use of convenience food and eating outside the home environment being linked to the obesity epidemic, the need to assess and monitor individuals cooking and food skills is key to help intervene where necessary to promote the usage of these skills. Therefore, this research aimed to develop and validate a measure for cooking skills and one for food skills, that are clearly described, relatable, user-friendly, suitable for different types of studies, and applicable across all sociodemographic levels. Two measures were developed in light of the literature and expert opinion and piloted for clarity and ease of use. Following this, four studies were undertaken across different cohorts (including a sample of students, both 'Food preparation novices' and 'Experienced food preparers', and a nationally representative sample) to assess temporal stability, psychometrics, internal consistency reliability and construct validity of both measures. Analysis included T-tests, Pearson's correlations, factor analysis, and Cronbach's alphas, with a significance level of 0.05. Both measures were found to have a significant level of temporal stability (P cooking skills confidence measure ranged from 0.78 to 0.93 across all cohorts. The food skills confidence measure's Cronbach's alpha's ranged from 0.85 to 0.94. The two measures also showed a high discriminate validity as there were significant differences (P cooking skills confidence and P cooking skills confidence measure and the food skills confidence measure have been shown to have a very satisfactory reliability, validity and are consistent over time. Their user-friendly applicability make both measures highly suitable for large scale cross-sectional, longitudinal and intervention studies to assess or monitor cooking and food skills levels and confidence.

  10. Consumer confidence in the safety of food in Canada and the Netherlands: The validation of a generic framework

    NARCIS (Netherlands)

    Jonge, de J.; Trijp, van J.C.M.; Goddard, E.; Frewer, L.J.

    2008-01-01

    A thorough understanding of consumer confidence in the safety of food and the factors by which this is influenced is necessary for the development of adequate and effective risk management and communication regarding food safety issues. As food chains become globalized, risk management and

  11. TJ-II Library Manual (Version 2)

    International Nuclear Information System (INIS)

    Tribaldos, V.; Milligen, B. Ph. van; Lopez-Fraguas, A.

    2001-01-01

    This is a manual of use of the TJ2 Numerical Library that has been developed for making numerical computations of different TJ-II configurations. This manual is a new version of the earlier manual CIEMAT report 806. (Author)

  12. Automated cerebellar segmentation: Validation and application to detect smaller volumes in children prenatally exposed to alcohol

    Directory of Open Access Journals (Sweden)

    Valerie A. Cardenas

    2014-01-01

    Discussion: These results demonstrate excellent reliability and validity of automated cerebellar volume and mid-sagittal area measurements, compared to manual measurements. These data also illustrate that this new technology for automatically delineating the cerebellum leads to conclusions regarding the effects of prenatal alcohol exposure on the cerebellum consistent with prior studies that used labor intensive manual delineation, even with a very small sample.

  13. Effect of Adding Interferential Current in an Exercise and Manual Therapy Program for Patients With Unilateral Shoulder Impingement Syndrome: A Randomized Clinical Trial.

    Science.gov (United States)

    Gomes, Cid André Fidelis de Paula; Dibai-Filho, Almir Vieira; Moreira, William Arruda; Rivas, Shirley Quispe; Silva, Emanuela Dos Santos; Garrido, Ana Claudia Bogik

    The purpose of this study was to measure the additional effect of adding interferential current (IFC) to an exercise and manual therapy program for patients with unilateral shoulder impingement syndrome. Forty-five participants were randomly assigned to group 1 (exercise and manual therapy), group 2 (exercise and manual therapy + IFC), or group 3 (exercise and manual therapy + placebo ultrasound). Individuals participated in 16 treatment sessions, twice a week for 8 weeks. The primary outcome of the study was total score of the Shoulder Pain and Disability Index (SPADI). The secondary outcomes were the pain and disability subscales of SPADI, Numeric Rating Scale, and Pain-Related Self-Statement Scale. Adjusted between-group mean differences (MDs) and 95% confidence intervals (CIs) were calculated using linear mixed models. After 16 treatment sessions, statistically significant but not clinically important differences were identified in favor of the exercise and manual therapy program alone in the SPADI-total (group 1 vs group 2, MD 11.12 points, 95% CI 5.90-16.35; group 1 vs group 3, MD 13.43 points, 95% CI 8.21-18.65). Similar results were identified for secondary outcomes. The addition of IFC does not generate greater clinical effects in an exercise and manual therapy program for individuals with unilateral shoulder impingement syndrome. Copyright © 2018. Published by Elsevier Inc.

  14. GERTS GQ User's Manual.

    Science.gov (United States)

    Akiba, Y.; And Others

    This user's manual for the simulation program Graphical Evaluation and Review Technique (GERT) GQ contains sections on nodes, branches, program input description and format, and program output, as well as examples. Also included is a programmer's manual which contains information on scheduling, subroutine descriptions, COMMON Variables, and…

  15. Nuclear electronics laboratory manual

    International Nuclear Information System (INIS)

    1984-05-01

    The Nuclear Electronics Laboratory Manual is a joint product of several electronics experts who have been associated with IAEA activity in this field for many years. The manual does not include experiments of a basic nature, such as characteristics of different active electronics components. It starts by introducing small electronics blocks, employing one or more active components. The most demanding exercises instruct a student in the design and construction of complete circuits, as used in commercial nuclear instruments. It is expected that a student who completes all the experiments in the manual should be in a position to design nuclear electronics units and also to understand the functions of advanced commercial instruments which need to be repaired or maintained. The future tasks of nuclear electronics engineers will be increasingly oriented towards designing and building the interfaces between a nuclear experiment and a computer. The manual pays tribute to this development by introducing a number of experiments which illustrate the principles and the technology of interfacing

  16. 14 CFR 121.141 - Airplane flight manual.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane flight manual. 121.141 Section 121... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Manual Requirements § 121.141 Airplane flight manual. (a) Each certificate holder shall keep a current approved airplane flight manual for each type of...

  17. Confidence Leak in Perceptual Decision Making.

    Science.gov (United States)

    Rahnev, Dobromir; Koizumi, Ai; McCurdy, Li Yan; D'Esposito, Mark; Lau, Hakwan

    2015-11-01

    People live in a continuous environment in which the visual scene changes on a slow timescale. It has been shown that to exploit such environmental stability, the brain creates a continuity field in which objects seen seconds ago influence the perception of current objects. What is unknown is whether a similar mechanism exists at the level of metacognitive representations. In three experiments, we demonstrated a robust intertask confidence leak-that is, confidence in one's response on a given task or trial influencing confidence on the following task or trial. This confidence leak could not be explained by response priming or attentional fluctuations. Better ability to modulate confidence leak predicted higher capacity for metacognition as well as greater gray matter volume in the prefrontal cortex. A model based on normative principles from Bayesian inference explained the results by postulating that observers subjectively estimate the perceptual signal strength in a stable environment. These results point to the existence of a novel metacognitive mechanism mediated by regions in the prefrontal cortex. © The Author(s) 2015.

  18. A multisite validation of whole slide imaging for primary diagnosis using standardized data collection and analysis

    Directory of Open Access Journals (Sweden)

    Katy Wack

    2016-01-01

    Full Text Available Context: Text-based reporting and manual arbitration for whole slide imaging (WSI validation studies are labor intensive and do not allow for consistent, scalable, and repeatable data collection or analysis. Objective: The objective of this study was to establish a method of data capture and analysis using standardized codified checklists and predetermined synoptic discordance tables and to use these methods in a pilot multisite validation study. Methods and Study Design: Fifteen case report form checklists were generated from the College of American Pathology cancer protocols. Prior to data collection, all hypothetical pairwise comparisons were generated, and a level of harm was determined for each possible discordance. Four sites with four pathologists each generated 264 independent reads of 33 cases. Preestablished discordance tables were applied to determine site by site and pooled accuracy, intrareader/intramodality, and interreader intramodality error rates. Results: Over 10,000 hypothetical pairwise comparisons were evaluated and assigned harm in discordance tables. The average difference in error rates between WSI and glass, as compared to ground truth, was 0.75% with a lower bound of 3.23% (95% confidence interval. Major discordances occurred on challenging cases, regardless of modality. The average inter-reader agreement across sites for glass was 76.5% (weighted kappa of 0.68 and for digital it was 79.1% (weighted kappa of 0.72. Conclusion: These results demonstrate the feasibility and utility of employing standardized synoptic checklists and predetermined discordance tables to gather consistent, comprehensive diagnostic data for WSI validation studies. This method of data capture and analysis can be applied in large-scale multisite WSI validations.

  19. Time Series Modeling of Human Operator Dynamics in Manual Control Tasks

    Science.gov (United States)

    Biezad, D. J.; Schmidt, D. K.

    1984-01-01

    A time-series technique is presented for identifying the dynamic characteristics of the human operator in manual control tasks from relatively short records of experimental data. Control of system excitation signals used in the identification is not required. The approach is a multi-channel identification technique for modeling multi-input/multi-output situations. The method presented includes statistical tests for validity, is designed for digital computation, and yields estimates for the frequency response of the human operator. A comprehensive relative power analysis may also be performed for validated models. This method is applied to several sets of experimental data; the results are discussed and shown to compare favorably with previous research findings. New results are also presented for a multi-input task that was previously modeled to demonstrate the strengths of the method.

  20. Validation of the Maslach Burnout Inventory - general survey : an Internet study

    NARCIS (Netherlands)

    Bakker, A.B.; Demerouti, E.; Schaufeli, W.B.

    2002-01-01

    This study examined the factorial validity of the Maslach Burnout Inventory - General Survey (MBI-GS; Schaufeli et al., Maslach Burnout Inventory Manual, pp. 19-26. Consulting Psychologists Press, CA) in eight different occupational groups of employees (N=2919), who were recruited through the

  1. Oil Spill Response Manual

    NARCIS (Netherlands)

    Marieke Zeinstra; Sandra Heins; Wierd Koops

    2014-01-01

    A two year programme has been carried out by the NHL University of Applied Sciences together with private companies in the field of oil and chemical spill response to finalize these manuals on oil and chemical spill response. These manuals give a good overview of all aspects of oil and chemical

  2. [Diagnostic validity of attention deficit/hyperactivity disorder: from phenomenology to neurobiology (I)].

    Science.gov (United States)

    Trujillo-Orrego, N; Pineda, D A; Uribe, L H

    2012-03-01

    The diagnostic criteria for the attentional deficit hyperactivity disorder (ADHD), were defined by the American Psychiatric Association in the Diagnostic and Statistical Manual of Mental Disorders fourth version (DSM-IV) and World Health Organization in the ICD-10. The American Psychiatric Association used an internal validity analysis to select specific behavioral symptoms associated with the disorder and to build five cross-cultural criteria for its use in the categorical diagnosis. The DSM has been utilized for clinicians and researchers as a valid and stable approach since 1968. We did a systematic review of scientific literature in Spanish and English, aimed to identify the historical origin that supports ADHD as a psychiatric construct. This comprehensive review started exploring the concept of minimal brain dysfunction, hyper-activity, inattention, impulsivity since 1932 to 2011. This paper summarize all the DSM versions that include the definition of ADHD or its equivalent, and it point out the statistical and methodological approach implemented for defining ADHD as a valid epidemiological and psychometric construct. Finally the paper discusses some considerations and suggestions for the new versions of the manual.

  3. 46 CFR 160.176-21 - User manuals.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false User manuals. 160.176-21 Section 160.176-21 Shipping...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Inflatable Lifejackets § 160.176-21 User manuals. (a) The manufacturer must develop a user's manual for each model of inflatable lifejacket. The content of the manual...

  4. US Department of Energy radiological control manual

    International Nuclear Information System (INIS)

    1994-04-01

    This manual establishes practices for the conduct of Department of Energy radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. This Manual is not a substitute for Regulations; it is intended to be consistent with all relevant statutory and regulatory requirements and shall be revised whenever necessary to ensure such consistency. Some of the Manual provisions, however, challenge the user to go well beyond minimum requirements. Following the course of action delineated in the Manual will result in achieving and surpassing related statutory or regulatory requirements

  5. Manual therapy in addition to physiotherapy does not improve clinical or economic outcomes after ankle fracture.

    Science.gov (United States)

    Lin, Chung-Wei Christine; Moseley, Anne M; Haas, Marion; Refshauge, Kathryn M; Herbert, Robert D

    2008-06-01

    The primary aim of this study was to determine the effectiveness and cost-effectiveness of adding manual therapy to a physiotherapy programme for ankle fracture. Assessor-blinded randomized controlled trial. Ninety-four adults were recruited within one week of cast removal for isolated ankle fracture. Inclusion criteria were: they were able to weight-bear as tolerated or partial weight-bear, were referred for physiotherapy, and experienced pain. Ninety-one participants completed the study. Participants were randomly allocated to receive manual therapy (anterior-posterior joint mobilization over the talus) plus a standard physiotherapy programme (experimental), or the standard physiotherapy programme only (control). They were assessed by a blinded assessor at baseline, and at 4, 12 and 24 weeks. The main outcomes were activity limitation and quality of life. Information on costs and healthcare utilization was collected every 4 weeks up to 24 weeks. There were no clinically worthwhile differences in activity limitation or quality of life between groups at any time-point. There was also no between-group difference in quality-adjusted life-years, but the experimental group incurred higher out-of-pocket costs (mean between-group difference = AU$200, 95% confidence interval 26-432). When provided in addition to a physiotherapy programme, manual therapy did not enhance outcome in adults after ankle fracture.

  6. Confidence Building Strategies in the Public Schools.

    Science.gov (United States)

    Achilles, C. M.; And Others

    1985-01-01

    Data from the Phi Delta Kappa Commission on Public Confidence in Education indicate that "high-confidence" schools make greater use of marketing and public relations strategies. Teacher attitudes were ranked first and administrator attitudes second by 409 respondents for both gain and loss of confidence in schools. (MLF)

  7. Technical Manual. The ACT®

    Science.gov (United States)

    ACT, Inc., 2014

    2014-01-01

    This manual contains technical information about the ACT® college readiness assessment. The principal purpose of this manual is to document the technical characteristics of the ACT in light of its intended purposes. ACT regularly conducts research as part of the ongoing formative evaluation of its programs. The research is intended to ensure that…

  8. Confidence judgment in depression and dysphoria: the depressive realism vs. negativity hypotheses.

    Science.gov (United States)

    Szu-Ting Fu, Tiffany; Koutstaal, Wilma; Poon, Lucia; Cleare, Anthony J

    2012-06-01

    According to the negativity hypothesis, depressed individuals are over-pessimistic due to negative self-concepts. In contrast, depressive realism suggests that depressed persons are realistic compared to their nondepressed controls. However, evidence supporting depressive realism predominantly comes from judgment comparisons between controls and nonclinical dysphoric samples when the controls showed overconfident bias. This study aimed to test the validity of the two accounts in clinical depression and dysphoria. Sixty-eight participants, including healthy controls (n = 32), patients with DSM-IV major depression (n = 20), and dysphoric participants with CDC-defined chronic fatigue syndrome (n = 16) performed an adjective recognition task and reported their item-by-item confidence judgments and post-test performance estimate (PTPE). Compared to realistic PTPE made by the controls, patients with major depression showed significant underconfidence. The PTPE of the dysphoric participants was relatively accurate. Both the depressed and dysphoric participants displayed less item-by-item overconfidence as opposed to significant item-by-item overconfidence shown by the controls. The judgment-accuracy patterns of the three groups need to be replicated with larger samples using non-memory task domains. The present study confirms depressive realism in dysphoric individuals. However, toward a more severe depressive emotional state, the findings did not support depressive realism but are in line with the prediction of the negativity hypothesis. It is not possible to determine the validity of the two hypotheses when the controls are overconfident. Dissociation between item-by-item and retrospective confidence judgments is discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Confidence rating of marine eutrophication assessments

    DEFF Research Database (Denmark)

    Murray, Ciarán; Andersen, Jesper Harbo; Kaartokallio, Hermanni

    2011-01-01

    of the 'value' of the indicators on which the primary assessment is made. Such secondary assessment of confidence represents a first step towards linking status classification with information regarding their accuracy and precision and ultimately a tool for improving or targeting actions to improve the health......This report presents the development of a methodology for assessing confidence in eutrophication status classifications. The method can be considered as a secondary assessment, supporting the primary assessment of eutrophication status. The confidence assessment is based on a transparent scoring...

  10. Environment, safety, and health manual, closeout report

    International Nuclear Information System (INIS)

    1975-12-01

    A coordination draft of the Environment, Safety, and Health (ES and H) manual was submitted on 2 September 1975. Comments provided by Operational Safety personnel were being incorporated by a task team when the effort was terminated on 31 October 1975. This report documents the development history of the manual and provides a status of the manual up to the time the efforts were discontinued. Also discussed are issues which effect completion of the manual. Additionally a plan for completion of the manual is suggested

  11. Psychiatry's new manual (DSM-5): ethical and conceptual dimensions.

    Science.gov (United States)

    Blumenthal-Barby, J S

    2014-08-01

    The introduction of the Diagnostic and statistical manual of mental disorders (DSM-5) in May 2013 is being hailed as the biggest event in psychiatry in the last 10 years. In this paper I examine three important issues that arise from the new manual:(1) Expanding nosology: Psychiatry has again broadened its nosology to include human experiences not previously under its purview (eg, binge eating disorder, internet gaming disorder, caffeine use disorder, hoarding disorder, premenstrual dysphoric disorder). Consequence-based ethical concerns about this expansion are addressed, along with conceptual concerns about a confusion of "construct validity" and "conceptual validity" and a failure to distinguish between "disorder" and "non disordered conditions for which we help people."(2) The role of claims about societal impact in changes in nosology: Several changes in the DSM-5 involved claims about societal impact in their rationales. This is due in part to a new online open comment period during DSM development. Examples include advancement of science, greater access to treatment, greater public awareness of condition, loss of identify or harm to those with removed disorders, stigmatization, offensiveness, etc. I identify and evaluate four importantly distinct ways in which claims about societal impact might operate in DSM development. (3) Categorisation nosology to spectrum nosology: The move to "degrees of severity" of mental disorders, a major change for DSM-5, raises concerns about conceptual clarity and uniformity concerning what it means to have a severe form of a disorder, and ethical concerns about communication. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. A semi-automated volumetric software for segmentation and perfusion parameter quantification of brain tumors using 320-row multidetector computed tomography: a validation study

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Soo Young; Suh, Sangil; Ryoo, Inseon; Park, Arim; Seol, Hae Young [Korea University Guro Hospital, Department of Radiology, Seoul (Korea, Republic of); Noh, Kyoung Jin [Soonchunhyang University, Department of Electronic Engineering, Asan (Korea, Republic of); Shim, Hackjoon [Toshiba Medical Systems Korea Co., Seoul (Korea, Republic of)

    2017-05-15

    We developed a semi-automated volumetric software, NPerfusion, to segment brain tumors and quantify perfusion parameters on whole-brain CT perfusion (WBCTP) images. The purpose of this study was to assess the feasibility of the software and to validate its performance compared with manual segmentation. Twenty-nine patients with pathologically proven brain tumors who underwent preoperative WBCTP between August 2012 and February 2015 were included. Three perfusion parameters, arterial flow (AF), equivalent blood volume (EBV), and Patlak flow (PF, which is a measure of permeability of capillaries), of brain tumors were generated by a commercial software and then quantified volumetrically by NPerfusion, which also semi-automatically segmented tumor boundaries. The quantification was validated by comparison with that of manual segmentation in terms of the concordance correlation coefficient and Bland-Altman analysis. With NPerfusion, we successfully performed segmentation and quantified whole volumetric perfusion parameters of all 29 brain tumors that showed consistent perfusion trends with previous studies. The validation of the perfusion parameter quantification exhibited almost perfect agreement with manual segmentation, with Lin concordance correlation coefficients (ρ {sub c}) for AF, EBV, and PF of 0.9988, 0.9994, and 0.9976, respectively. On Bland-Altman analysis, most differences between this software and manual segmentation on the commercial software were within the limit of agreement. NPerfusion successfully performs segmentation of brain tumors and calculates perfusion parameters of brain tumors. We validated this semi-automated segmentation software by comparing it with manual segmentation. NPerfusion can be used to calculate volumetric perfusion parameters of brain tumors from WBCTP. (orig.)

  13. A semi-automated volumetric software for segmentation and perfusion parameter quantification of brain tumors using 320-row multidetector computed tomography: a validation study.

    Science.gov (United States)

    Chae, Soo Young; Suh, Sangil; Ryoo, Inseon; Park, Arim; Noh, Kyoung Jin; Shim, Hackjoon; Seol, Hae Young

    2017-05-01

    We developed a semi-automated volumetric software, NPerfusion, to segment brain tumors and quantify perfusion parameters on whole-brain CT perfusion (WBCTP) images. The purpose of this study was to assess the feasibility of the software and to validate its performance compared with manual segmentation. Twenty-nine patients with pathologically proven brain tumors who underwent preoperative WBCTP between August 2012 and February 2015 were included. Three perfusion parameters, arterial flow (AF), equivalent blood volume (EBV), and Patlak flow (PF, which is a measure of permeability of capillaries), of brain tumors were generated by a commercial software and then quantified volumetrically by NPerfusion, which also semi-automatically segmented tumor boundaries. The quantification was validated by comparison with that of manual segmentation in terms of the concordance correlation coefficient and Bland-Altman analysis. With NPerfusion, we successfully performed segmentation and quantified whole volumetric perfusion parameters of all 29 brain tumors that showed consistent perfusion trends with previous studies. The validation of the perfusion parameter quantification exhibited almost perfect agreement with manual segmentation, with Lin concordance correlation coefficients (ρ c ) for AF, EBV, and PF of 0.9988, 0.9994, and 0.9976, respectively. On Bland-Altman analysis, most differences between this software and manual segmentation on the commercial software were within the limit of agreement. NPerfusion successfully performs segmentation of brain tumors and calculates perfusion parameters of brain tumors. We validated this semi-automated segmentation software by comparing it with manual segmentation. NPerfusion can be used to calculate volumetric perfusion parameters of brain tumors from WBCTP.

  14. Marketing Research. Instructor's Manual.

    Science.gov (United States)

    Small Business Administration, Washington, DC.

    Prepared for the Administrative Management Course Program, this instructor's manual was developed to serve small-business management needs. The sections of the manual are as follows: (1) Lesson Plan--an outline of material covered, which may be used as a teaching guide, presented in two columns: the presentation, and a step-by-step indication of…

  15. Indoor Air Quality Manual.

    Science.gov (United States)

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  16. 25 CFR 175.5 - Operations manual.

    Science.gov (United States)

    2010-04-01

    ... Provisions § 175.5 Operations manual. (a) The Area Director shall establish an operations manual for the... Director shall amend the operations manual as needed. (b) The public shall be notified by the Area Director... shall be published in local newspaper(s) of general circulation, posted at the utility office(s), and...

  17. AFM-CMM integrated instrument user manual

    DEFF Research Database (Denmark)

    Marinello, Francesco; Bariani, Paolo

    This manual gives general important guidelines for a proper use of the integrated AFM-CMM instrument. More information can be collected reading: • N. Kofod Ph.D thesis [1]; • P. Bariani Ph.D thesis [2]; • Dualscope DME 95-200 operation manuals [3]; • SPIP help [4] • Stitching software user manual...

  18. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-07-25

    The purpose of the Regulations and Procedures Manual (RPM) is to provide LBNL personnel with a reference to University and Lawrence Berkeley National Laboratory (LBNL or Laboratory) policies and regulations by outlining normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory organizations. Much of the information in this manual has been condensed from detail provided in LBNL procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. RPM sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the LBNL organization responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which organization is responsible for a policy, please contact Requirements Manager Lydia Young or the RPM Editor.

  19. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2010-09-30

    The purpose of the Regulations and Procedures Manual (RPM) is to provide Laboratory personnel with a reference to University and Lawrence Berkeley National Laboratory policies and regulations by outlining the normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory departments. Much of the information in this manual has been condensed from detail provided in Laboratory procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. The sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the department responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which department should be called, please contact the Associate Laboratory Director of Operations.

  20. Manual for subject analysis

    International Nuclear Information System (INIS)

    2002-01-01

    This document is one in a series of publications known as the ETDE/INIS Joint Reference Series and also constitutes a part of the ETDE Procedures Manual. It presents the rules, guidelines and procedures to be adopted by centers submitting input to the International Nuclear Information System (INIS) or the Energy Technology Data Exchange (ETDE). It is a manual for the subject analysis part of input preparation, meaning the selection, subject classification, abstracting and subject indexing of relevant publications, and is to be used in conjunction with the Thesauruses, Subject Categories documents and the documents providing guidelines for the preparation of abstracts. The concept and structure of the new manual are intended to describe in a logical and efficient sequence all the steps comprising the subject analysis of documents to be reported to INIS or ETDE. The manual includes new chapters on preparatory analysis, subject classification, abstracting and subject indexing, as well as rules, guidelines, procedures, examples and a special chapter on guidelines and examples for subject analysis in particular subject fields. (g.t.; a.n.)

  1. Activity Management System user reference manual. Revision 1

    International Nuclear Information System (INIS)

    Gates, T.A.; Burdick, M.B.

    1994-01-01

    The Activity Management System (AMS) was developed in response to the need for a simple-to-use, low-cost, user interface system for collecting and logging Hanford Waste Vitrification Plant Project (HWVP) activities. This system needed to run on user workstations and provide common user access to a database stored on a local network file server. Most important, users wanted a system that provided a management tool that supported their individual process for completing activities. Existing system treated the performer as a tool of the system. All AMS data is maintained in encrypted format. Users can feel confident that any activities they have entered into the database are private and that, as the originator, they retain sole control over who can see them. Once entered into the AMS database, the activities cannot be accessed by anyone other than the originator, the designated agent, or by authorized viewers who have been explicitly granted the right to look at specific activities by the originator. This user guide is intended to assist new AMS users in learning how to use the application and, after the initial learning process, will serve as an ongoing reference for experienced users in performing infrequently used functions. Online help screens provide reference to some of the key information in this manual. Additional help screens, encompassing all the applicable material in this manual, will be incorporated into future AMS revisions. A third, and most important, source of help is the AMS administrator(s). This guide describes the initial production version of AMS, which has been designated Revision 1.0

  2. Reconceptualising manual therapy skills in contemporary practice.

    Science.gov (United States)

    Rabey, Martin; Hall, Toby; Hebron, Clair; Palsson, Thorvaldur Skuli; Christensen, Steffan Wittrup; Moloney, Niamh

    2017-06-01

    With conflicting evidence regarding the effectiveness of manual therapy calls have arisen within some quarters of the physiotherapy profession challenging the continued use of manual skills for assessment and treatment. A reconceptualisation of the importance of manual examination findings is put forward, based upon a contemporary understanding of pain science, rather than considering these skills only in terms of how they should "guide" manual therapy interventions. The place for manual examination findings within complex, multidimensional presentations is considered using vignettes describing the presentations of five people with low back pain. As part of multidimensional, individualised management, the balance of evidence relating to the effectiveness, mechanisms of action and rationale for manual skills is discussed. It is concluded that if manual examination and therapeutic skills are used in a manner consistent with a contemporary understanding of pain science, multidimensional patient profiles and a person-centred approach, their selective and judicious use still has an important role. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Semiautomated segmentation of blood vessels using ellipse-overlap criteria: Method and comparison to manual editing

    International Nuclear Information System (INIS)

    Shiffman, Smadar; Rubin, Geoffrey D.; Schraedley-Desmond, Pamela; Napel, Sandy

    2003-01-01

    Two-dimensional intensity-based methods for the segmentation of blood vessels from computed-tomography-angiography data often result in spurious segments that originate from other objects whose intensity distributions overlap with those of the vessels. When segmented images include spurious segments, additional methods are required to select segments that belong to the target vessels. We describe a method that allows experts to select vessel segments from sequences of segmented images with little effort. Our method uses ellipse-overlap criteria to differentiate between segments that belong to different objects and are separated in plane but are connected in the through-plane direction. To validate our method, we used it to extract vessel regions from volumes that were segmented via analysis of isolabel-contour maps, and showed that the difference between the results of our method and manually-edited results was within inter-expert variability. Although the total editing duration for our method, which included user-interaction and computer processing, exceeded that of manual editing, the extent of user interaction required for our method was about a fifth of that required for manual editing

  4. Confidence bands for inverse regression models

    International Nuclear Information System (INIS)

    Birke, Melanie; Bissantz, Nicolai; Holzmann, Hajo

    2010-01-01

    We construct uniform confidence bands for the regression function in inverse, homoscedastic regression models with convolution-type operators. Here, the convolution is between two non-periodic functions on the whole real line rather than between two periodic functions on a compact interval, since the former situation arguably arises more often in applications. First, following Bickel and Rosenblatt (1973 Ann. Stat. 1 1071–95) we construct asymptotic confidence bands which are based on strong approximations and on a limit theorem for the supremum of a stationary Gaussian process. Further, we propose bootstrap confidence bands based on the residual bootstrap and prove consistency of the bootstrap procedure. A simulation study shows that the bootstrap confidence bands perform reasonably well for moderate sample sizes. Finally, we apply our method to data from a gel electrophoresis experiment with genetically engineered neuronal receptor subunits incubated with rat brain extract

  5. TRUBA User Manual

    International Nuclear Information System (INIS)

    Tereshchenko, M. A.; Castejon, F.; Cappa, A.

    2008-01-01

    The TRUBA (pipeline in Russian) code is a computational tool for studying the propagation of Gaussian-shaped microwave beams in a prescribed equilibrium plasma. This manual covers the basic material handed to use the implementation of TRUBA (version 3,4) interfaced with the numerical library of the TJ-II stellarator. The manual provides a concise theoretical background of the problem, specifications for setting up the input files and interpreting the output of the code, and some information useful in modifying TRUBA. (Author) 13 refs

  6. TRUBA User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Tereshchenko, M. A.; Castejon, F.; Cappa, A.

    2008-04-25

    The TRUBA (pipeline in Russian) code is a computational tool for studying the propagation of Gaussian-shaped microwave beams in a prescribed equilibrium plasma. This manual covers the basic material handed to use the implementation of TRUBA (version 3,4) interfaced with the numerical library of the TJ-II stellarator. The manual provides a concise theoretical background of the problem, specifications for setting up the input files and interpreting the output of the code, and some information useful in modifying TRUBA. (Author) 13 refs.

  7. Nuclear power: restoring public confidence

    International Nuclear Information System (INIS)

    Arnold, L.

    1986-01-01

    The paper concerns a one day conference on nuclear power organised by the Centre for Science Studies and Science Policy, Lancaster, April 1986. Following the Chernobyl reactor accident, the conference concentrated on public confidence in nuclear power. Causes of lack of public confidence, public perceptions of risk, and the effect of Chernobyl in the United Kingdom, were all discussed. A Select Committee on the Environment examined the problems of radioactive waste disposal. (U.K.)

  8. Developing a Pupil Transportation Manual.

    Science.gov (United States)

    Douglas, Dave

    1987-01-01

    District-level pupil transportation manuals that contain clear, concise information about objectives, policies, and regulations are a must. These manuals should also specify procedures concerning evaluation processes, personnel recruitment and selection, and the driver training program. (MLH)

  9. Content validity and its estimation

    Directory of Open Access Journals (Sweden)

    Yaghmale F

    2003-04-01

    Full Text Available Background: Measuring content validity of instruments are important. This type of validity can help to ensure construct validity and give confidence to the readers and researchers about instruments. content validity refers to the degree that the instrument covers the content that it is supposed to measure. For content validity two judgments are necessary: the measurable extent of each item for defining the traits and the set of items that represents all aspects of the traits. Purpose: To develop a content valid scale for assessing experience with computer usage. Methods: First a review of 2 volumes of International Journal of Nursing Studies, was conducted with onlyI article out of 13 which documented content validity did so by a 4-point content validity index (CV! and the judgment of 3 experts. Then a scale with 38 items was developed. The experts were asked to rate each item based on relevance, clarity, simplicity and ambiguity on the four-point scale. Content Validity Index (CVI for each item was determined. Result: Of 38 items, those with CVIover 0.75 remained and the rest were discarded reSulting to 25-item scale. Conclusion: Although documenting content validity of an instrument may seem expensive in terms of time and human resources, its importance warrants greater attention when a valid assessment instrument is to be developed. Keywords: Content Validity, Measuring Content Validity

  10. Statins and the Risk of Intracerebral Hemorrhage in Patients With Previous Ischemic Stroke or Transient Ischemic Attack

    DEFF Research Database (Denmark)

    Gaist, David; Goldstein, Larry B; Cea Soriano, Lucía

    2017-01-01

    to identify incident cases of ICH, with validation by manual review of patient records and linkage to hospitalization data. In a nested case-control study, we compared the adjusted odds ratios (ORs) with 95% confidence intervals (CIs) for ICH based on statin use in the subgroup of individuals with history...

  11. The Investigation of Construct Validity of Diagnostic and Statistical Manual of Mental Disorder-5 Personality Traits on Iranian sample with Antisocial and Borderline Personality Disorders.

    Science.gov (United States)

    Amini, Mehdi; Pourshahbaz, Abbas; Mohammadkhani, Parvaneh; Ardakani, Mohammad-Reza Khodaie; Lotfi, Mozhgan

    2014-12-01

    The goal of this study was to examine the construct validity of the diagnostic and statistical manual of mental disorder-5 (DSM-5) conceptual model of antisocial and borderline personality disorders (PDs). More specifically, the aim was to determine whether the DSM-5 five-factor structure of pathological personality trait domains replicated in an independently collected sample that differs culturally from the derivation sample. This study was on a sample of 346 individuals with antisocial (n = 122) and borderline PD (n = 130), and nonclinical subjects (n = 94). Participants randomly selected from prisoners, out-patient, and in-patient clients. Participants were recruited from Tehran prisoners, and clinical psychology and psychiatry clinics of Razi and Taleghani Hospital, Tehran, Iran. The SCID-II-PQ, SCID-II, DSM-5 Personality Trait Rating Form (Clinician's PTRF) were used to diagnosis of PD and to assessment of pathological traits. The data were analyzed by exploratory factor analysis. Factor analysis revealed a 5-factor solution for DSM-5 personality traits. Results showed that DSM-5 has adequate construct validity in Iranian sample with antisocial and borderline PDs. Factors similar in number with the other studies, but different in the content. Exploratory factor analysis revealed five homogeneous components of antisocial and borderline PDs. That may represent personality, behavioral, and affective features central to the disorder. Furthermore, the present study helps understand the adequacy of DSM-5 dimensional approach to evaluation of personality pathology, specifically on Iranian sample.

  12. The investigation of construct validity of diagnostic and statistical manual of mental disorder-5 personality traits on iranian sample with antisocial and borderline personality disorders

    Directory of Open Access Journals (Sweden)

    Mehdi Amini

    2014-01-01

    Full Text Available Background: The goal of this study was to examine the construct validity of the diagnostic and statistical manual of mental disorder-5 (DSM-5 conceptual model of antisocial and borderline personality disorders (PDs. More specifically, the aim was to determine whether the DSM-5 five-factor structure of pathological personality trait domains replicated in an independently collected sample that differs culturally from the derivation sample. Methods: This study was on a sample of 346 individuals with antisocial (n = 122 and borderline PD (n = 130, and nonclinical subjects (n = 94. Participants randomly selected from prisoners, out-patient, and in-patient clients . Participants were recruited from Tehran prisoners, and clinical psychology and psychiatry clinics of Razi and Taleghani Hospital, Tehran, Iran. The SCID-II-PQ, SCID-II, DSM-5 Personality Trait Rating Form (Clinician′s PTRF were used to diagnosis of PD and to assessment of pathological traits. The data were analyzed by exploratory factor analysis. Results: Factor analysis revealed a 5-factor solution for DSM-5 personality traits. Results showed that DSM-5 has adequate construct validity in Iranian sample with antisocial and borderline PDs. Factors similar in number with the other studies, but different in the content. Conclusions: Exploratory factor analysis revealed five homogeneous components of antisocial and borderline PDs. That may represent personality, behavioral, and affective features central to the disorder. Furthermore, the present study helps understand the adequacy of DSM-5 dimensional approach to evaluation of personality pathology, specifically on Iranian sample.

  13. Missouri Highway Safety Manual Recalibration

    Science.gov (United States)

    2018-05-01

    The Highway Safety Manual (HSM) is a national manual for analyzing the highway safety of various facilities, including rural roads, urban arterials, freeways, and intersections. The HSM was first published in 2010, and a 2014 supplement addressed fre...

  14. US Department of Energy Radiological Control Manual

    International Nuclear Information System (INIS)

    1992-06-01

    This manual establishes practices for the conduct of radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. (VC)

  15. Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning

    International Nuclear Information System (INIS)

    DeVries, Nicole A.; Gassman, Esther E.; Kallemeyn, Nicole A.; Shivanna, Kiran H.; Magnotta, Vincent A.; Grosland, Nicole M.

    2008-01-01

    To examine the validity of manually defined bony regions of interest from computed tomography (CT) scans. Segmentation measurements were performed on the coronal reformatted CT images of the three phalanx bones of the index finger from five cadaveric specimens. Two smoothing algorithms (image-based and Laplacian surface-based) were evaluated to determine their ability to represent accurately the anatomic surface. The resulting surfaces were compared with laser surface scans of the corresponding cadaveric specimen. The average relative overlap between two tracers was 0.91 for all bones. The overall mean difference between the manual unsmoothed surface and the laser surface scan was 0.20 mm. Both image-based and Laplacian surface-based smoothing were compared; the overall mean difference for image-based smoothing was 0.21 mm and 0.20 mm for Laplacian smoothing. This study showed that manual segmentation of high-contrast, coronal, reformatted, CT datasets can accurately represent the true surface geometry of bones. Additionally, smoothing techniques did not significantly alter the surface representations. This validation technique should be extended to other bones, image segmentation and spatial filtering techniques. (orig.)

  16. Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning

    Energy Technology Data Exchange (ETDEWEB)

    DeVries, Nicole A.; Gassman, Esther E.; Kallemeyn, Nicole A. [The University of Iowa, Department of Biomedical Engineering, Center for Computer Aided Design, Iowa City, IA (United States); Shivanna, Kiran H. [The University of Iowa, Center for Computer Aided Design, Iowa City, IA (United States); Magnotta, Vincent A. [The University of Iowa, Department of Biomedical Engineering, Department of Radiology, Center for Computer Aided Design, Iowa City, IA (United States); Grosland, Nicole M. [The University of Iowa, Department of Biomedical Engineering, Department of Orthopaedics and Rehabilitation, Center for Computer Aided Design, Iowa City, IA (United States)

    2008-01-15

    To examine the validity of manually defined bony regions of interest from computed tomography (CT) scans. Segmentation measurements were performed on the coronal reformatted CT images of the three phalanx bones of the index finger from five cadaveric specimens. Two smoothing algorithms (image-based and Laplacian surface-based) were evaluated to determine their ability to represent accurately the anatomic surface. The resulting surfaces were compared with laser surface scans of the corresponding cadaveric specimen. The average relative overlap between two tracers was 0.91 for all bones. The overall mean difference between the manual unsmoothed surface and the laser surface scan was 0.20 mm. Both image-based and Laplacian surface-based smoothing were compared; the overall mean difference for image-based smoothing was 0.21 mm and 0.20 mm for Laplacian smoothing. This study showed that manual segmentation of high-contrast, coronal, reformatted, CT datasets can accurately represent the true surface geometry of bones. Additionally, smoothing techniques did not significantly alter the surface representations. This validation technique should be extended to other bones, image segmentation and spatial filtering techniques. (orig.)

  17. Students' confidence in the ability to transfer basic math skills in introductory physics and chemistry courses at a community college

    Science.gov (United States)

    Quinn, Reginald

    2013-01-01

    The purpose of this study was to examine the confidence levels that community college students have in transferring basic math skills to science classes, as well as any factors that influence their confidence levels. This study was conducted with 196 students at a community college in central Mississippi. The study was conducted during the month of November after all of the students had taken their midterm exams and received midterm grades. The instrument used in this survey was developed and validated by the researcher. The instrument asks the students to rate how confident they were in working out specific math problems and how confident they were in working problems using those specific math skills in physics and chemistry. The instrument also provided an example problem for every confidence item. Results revealed that students' demographics were significant predictors in confidence scores. Students in the 18-22 year old range were less confident in solving math problems than others. Students who had retaken a math course were less confident than those who had not. Chemistry students were less confident in solving math problems than those in physics courses. Chemistry II students were less confident than those in Chemistry I and Principals of Chemistry. Students were least confident in solving problems involving logarithms and the most confident in solving algebra problems. In general, students felt that their math courses did not prepare them for the math problems encountered in science courses. There was no significant difference in confidence between students who had completed their math homework online and those who had completed their homework on paper. The researcher recommends that chemistry educators find ways of incorporating more mathematics in their courses especially logarithms and slope. Furthermore, math educators should incorporate more chemistry related applications to math class. Results of hypotheses testing, conclusions, discussions, and

  18. Quantitative and statistical approaches to geography a practical manual

    CERN Document Server

    Matthews, John A

    2013-01-01

    Quantitative and Statistical Approaches to Geography: A Practical Manual is a practical introduction to some quantitative and statistical techniques of use to geographers and related scientists. This book is composed of 15 chapters, each begins with an outline of the purpose and necessary mechanics of a technique or group of techniques and is concluded with exercises and the particular approach adopted. These exercises aim to enhance student's ability to use the techniques as part of the process by which sound judgments are made according to scientific standards while tackling complex problems. After a brief introduction to the principles of quantitative and statistical geography, this book goes on dealing with the topics of measures of central tendency; probability statements and maps; the problem of time-dependence, time-series analysis, non-normality, and data transformations; and the elements of sampling methodology. Other chapters cover the confidence intervals and estimation from samples, statistical hy...

  19. A Kinematic Study of Prosodic Structure in Articulatory and Manual Gestures: Results from a Novel Method of Data Collection

    Directory of Open Access Journals (Sweden)

    Jelena Krivokapić

    2017-03-01

    Full Text Available The primary goal of this work is to examine prosodic structure as expressed concurrently through articulatory and manual gestures. Specifically, we investigated the effects of phrase-level prominence (Experiment 1 and of prosodic boundaries (Experiments 2 and 3 on the kinematic properties of oral constriction and manual gestures. The hypothesis guiding this work is that prosodic structure will be similarly expressed in both modalities. To test this, we have developed a novel method of data collection that simultaneously records speech audio, vocal tract gestures (using electromagnetic articulometry and manual gestures (using motion capture. This method allows us, for the first time, to investigate kinematic properties of body movement and vocal tract gestures simultaneously, which in turn allows us to examine the relationship between speech and body gestures with great precision. A second goal of the paper is thus to establish the validity of this method. Results from two speakers show that manual and oral gestures lengthen under prominence and at prosodic boundaries, indicating that the effects of prosodic structure extend beyond the vocal tract to include body movement.1

  20. Organic labbeling systems and consumer confidence

    OpenAIRE

    Sønderskov, Kim Mannemar; Daugbjerg, Carsten

    2009-01-01

    A research analysis suggests that a state certification and labelling system creates confidence in organic labelling systems and consequently green consumerism. Danish consumers have higher levels of confidence in the labelling system than consumers in countries where the state plays a minor role in labelling and certification.

  1. Feedback for reinforcement learning based brain-machine interfaces using confidence metrics

    Science.gov (United States)

    Prins, Noeline W.; Sanchez, Justin C.; Prasad, Abhishek

    2017-06-01

    Objective. For brain-machine interfaces (BMI) to be used in activities of daily living by paralyzed individuals, the BMI should be as autonomous as possible. One of the challenges is how the feedback is extracted and utilized in the BMI. Our long-term goal is to create autonomous BMIs that can utilize an evaluative feedback from the brain to update the decoding algorithm and use it intelligently in order to adapt the decoder. In this study, we show how to extract the necessary evaluative feedback from a biologically realistic (synthetic) source, use both the quantity and the quality of the feedback, and how that feedback information can be incorporated into a reinforcement learning (RL) controller architecture to maximize its performance. Approach. Motivated by the perception-action-reward cycle (PARC) in the brain which links reward for cognitive decision making and goal-directed behavior, we used a reward-based RL architecture named Actor-Critic RL as the model. Instead of using an error signal towards building an autonomous BMI, we envision to use a reward signal from the nucleus accumbens (NAcc) which plays a key role in the linking of reward to motor behaviors. To deal with the complexity and non-stationarity of biological reward signals, we used a confidence metric which was used to indicate the degree of feedback accuracy. This confidence was added to the Actor’s weight update equation in the RL controller architecture. If the confidence was high (>0.2), the BMI decoder used this feedback to update its parameters. However, when the confidence was low, the BMI decoder ignored the feedback and did not update its parameters. The range between high confidence and low confidence was termed as the ‘ambiguous’ region. When the feedback was within this region, the BMI decoder updated its weight at a lower rate than when fully confident, which was decided by the confidence. We used two biologically realistic models to generate synthetic data for MI (Izhikevich

  2. Consumer confidence or the business cycle

    DEFF Research Database (Denmark)

    Møller, Stig Vinther; Nørholm, Henrik; Rangvid, Jesper

    2014-01-01

    Answer: The business cycle. We show that consumer confidence and the output gap both excess returns on stocks in many European countries: When the output gap is positive (the economy is doing well), expected returns are low, and when consumer confidence is high, expected returns are also low...

  3. Reconceptualising manual therapy skills in contemporary practice

    DEFF Research Database (Denmark)

    Rabey, Martin; Hall, Toby; Hebron, Clair

    2017-01-01

    With conflicting evidence regarding the effectiveness of manual therapy calls have arisen within some quarters of the physiotherapy profession challenging the continued use of manual skills for assessment and treatment. A reconceptualisation of the importance of manual examination findings is put...

  4. New highway accident location manual for Missouri.

    Science.gov (United States)

    2013-12-01

    The Missouri HAL manual is used to identify, analyze, and correct high crash locations, and has not been updated since : 1999. This new edition brings the manual up to date, while incorporating the methodology of the national Highway Safety : Manual ...

  5. Validating the proposed diagnostic and statistical manual of mental disorders, 5th edition, severity indicator for personality disorder.

    Science.gov (United States)

    Morey, Leslie C; Bender, Donna S; Skodol, Andrew E

    2013-09-01

    The authors sought to determine whether a 5-point global rating of personality dysfunction on the Level of Personality Functioning Scale proposed as a severity index for Diagnostic and Statistical Manual of Mental Disorders, 5th Edition (DSM-5), would be related to DSM-IV personality disorder diagnosis as well as to other key clinical judgments. Data were collected from a national sample of 337 mental health clinicians who provided complete diagnostic information relevant to DSM-IV and proposed DSM-5 personality disorder diagnoses, as well as demographic information and other clinical judgments, on one of their patients. Of the 337 patients described, 248 met criteria for 1 of the 10 specific DSM-IV personality disorders. A "moderate" or greater rating of impairment in personality functioning on the Level Scale demonstrated 84.6% sensitivity and 72.7% specificity for identifying patients meeting criteria for a specific DSM-IV personality disorder. The Level of Personality Functioning Scale had significant and substantial validity correlations with other measures of personality pathology and with clinical judgments regarding functioning, risk, prognosis, and optimal treatment intensity. Furthermore, the single-item Level of Personality Functioning rating was viewed as being as clinically useful as the 10 DSM-IV categories for treatment planning and patient description and was a better predictor of clinician ratings of broad psychosocial functioning than were the 10 DSM-IV categories combined. These results confirm hypotheses that the single-item Level of Personality Functioning Scale rating provides an indication of severity of personality pathology that predicts both assignment of personality disorder diagnosis and clinician appraisals of functioning, risk, prognosis, and needed treatment intensity.

  6. Binge Eating Disorder: Reliability and Validity of a New Diagnostic Category.

    Science.gov (United States)

    Brody, Michelle L.; And Others

    1994-01-01

    Examined reliability and validity of binge eating disorder (BED), proposed for inclusion in Diagnostic and Statistical Manual of Mental Disorders (DSM), fourth edition. Interrater reliability of BED diagnosis compared favorably with that of most diagnoses in DSM revised third edition. Study comparing obese individuals with and without BED and…

  7. Validity of "DSM-IV" Syndromes in Preschoolers with Autism Spectrum Disorders

    Science.gov (United States)

    Lecavalier, Luc; Gadow, Kenneth D.; Devincent, Carla J.; Houts, Carrie R.; Edwards, Michael C.

    2011-01-01

    Behavior and emotional problems are often present in very young children with autism spectrum disorders (ASDs) but their nosology has been the object of scant empirical attention. The objective of this study was to assess the construct validity of select "Diagnostic and Statistical Manual of Mental Disorders" ("DSM)"--defined…

  8. Communication confidence in persons with aphasia.

    Science.gov (United States)

    Babbitt, Edna M; Cherney, Leora R

    2010-01-01

    Communication confidence is a construct that has not been explored in the aphasia literature. Recently, national and international organizations have endorsed broader assessment methods that address quality of life and include participation, activity, and impairment domains as well as psychosocial areas. Individuals with aphasia encounter difficulties in all these areas on a daily basis in living with a communication disorder. Improvements are often reflected in narratives that are not typically included in standard assessments. This article illustrates how a new instrument measuring communication confidence might fit into a broad assessment framework and discusses the interaction of communication confidence, autonomy, and self-determination for individuals living with aphasia.

  9. Manual lymphatic drainage and therapeutic ultrasound in liposuction and lipoabdominoplasty post-operative period

    Directory of Open Access Journals (Sweden)

    Igor F. B. Masson

    2014-01-01

    Full Text Available Background: Physiotherapy in the plastic surgery post-operative (PO is essential to provide means for an adequate and fast recovery as it restores function through the use of physiotherapeutic procedures. Aim: The aim of the following study is to verify the effects of the association between the manual lymphatic drainage and the therapeutic ultrasound on pain, oedema and the tissue fibrosis in liposuction and lipoabdominoplasty PO. Design: This is a clinical trial prospective. Materials and Methods: Eighteen women aged between 18 and 60 years participated in this study, in the late PO period following lipoabdominoplasty or liposuction in the abdomen, flanks and lower trunk, which showed tissue fibrosis of the flanks and abdomen regions. They were divided into two groups: Liposuction group and lipoabdominoplasty group. A total of twelve sessions of therapeutic ultrasound followed by the manual lymphatic drainage were performed. The patients were assessed with regard to pain, oedema and tissue fibrosis in different moments: Initial assessment, during assessment and final assessment through the application of the protocol of evaluation of cysts fibrosis levels. Statistical Analysis: The test of equality for two proportions and the confidence interval test for mean to evaluate the distribution of variables. The significance level adopted for statistical tests was 5% (P < 0.05. Results: There was a statistically significant reduction of pain, swelling and tissue fibrosis in both groups. Conclusion: the association between manual lymphatic drainage and the therapeutic ultrasound reduced the swelling and the tissue fibrosis and made pain disappear in liposuction and lipoabdominoplasty PO period.

  10. Managing bottlenecks in manual automobile assembly systems using discrete event simulation

    Directory of Open Access Journals (Sweden)

    Dewa, M.

    2013-08-01

    Full Text Available Batch model lines are quite handy when the demand for each product is moderate. However, they are characterised by high work-in-progress inventories, lost production time when changing over models, and reduced flexibility when it comes to altering production rates as product demand changes. On the other hand, mixed model lines can offer reduced work-in-progress inventory and increased flexibility. The object of this paper is to illustrate that a manual automobile assembling system can be optimised through managing bottlenecks by ensuring high workstation utilisation, reducing queue lengths before stations and reducing station downtime. A case study from the automobile industry is used for data collection. A model is developed through the use of simulation software. The model is then verified and validated before a detailed bottleneck analysis is conducted. An operational strategy is then proposed for optimal bottleneck management. Although the paper focuses on improving automobile assembly systems in batch mode, the methodology can also be applied in single model manual and automated production lines.

  11. Aircraft operations management manual

    Science.gov (United States)

    1992-01-01

    The NASA aircraft operations program is a multifaceted, highly diverse entity that directly supports the agency mission in aeronautical research and development, space science and applications, space flight, astronaut readiness training, and related activities through research and development, program support, and mission management aircraft operations flights. Users of the program are interagency, inter-government, international, and the business community. This manual provides guidelines to establish policy for the management of NASA aircraft resources, aircraft operations, and related matters. This policy is an integral part of and must be followed when establishing field installation policy and procedures covering the management of NASA aircraft operations. Each operating location will develop appropriate local procedures that conform with the requirements of this handbook. This manual should be used in conjunction with other governing instructions, handbooks, and manuals.

  12. Use of a Short-Form Balance Confidence Scale to Predict Future Recurrent Falls in People With Parkinson Disease.

    Science.gov (United States)

    Cole, Michael H; Rippey, Jodi; Naughton, Geraldine A; Silburn, Peter A

    2016-01-01

    To assess whether the 16-item Activities-specific Balance Confidence scale (ABC-16) and short-form 6-item Activities-specific Balance Confidence scale (ABC-6) could predict future recurrent falls in people with Parkinson disease (PD) and to validate the robustness of their predictive capacities. Twelve-month prospective cohort study. General community. People with idiopathic PD (N=79). Clinical tests were conducted to assess symptom severity, balance confidence, and medical history. Over the subsequent 12 months, participants recorded any falls on daily fall calendars, which they returned monthly by reply paid post. Logistic regression and receiver operating characteristic analyses estimated the sensitivities and specificities of the ABC-16 and ABC-6 for predicting future recurrent falls in this cohort, and "leave-one-out" validation was used to assess their robustness. Of the 79 patients who completed follow-up, 28 (35.4%) fell more than once during the 12-month period. Both the ABC-16 and ABC-6 were significant predictors of future recurrent falls, and moderate sensitivities (ABC-16: 75.0%; ABC-6: 71.4%) and specificities (ABC-16: 76.5%; ABC-6: 74.5%) were reported for each tool for a cutoff score of 77.5 and 65.8, respectively. The results have significant implications and demonstrate that the ABC-16 and ABC-6 independently identify patients with PD at risk of future recurrent falls. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. ETAP user's manual

    International Nuclear Information System (INIS)

    Watanabe, Norio; Higuchi, Suminori.

    1990-11-01

    The event tree analysis technique has been used in Probabilistic Safety Assessment for LWRs to delineate various accident scenarios leading to core melt or containment failure and to evaluate their frequencies. This technique often requires manual preparation of event trees with iterative process and time-consuming work in data handling. For the purpose of reducing manual efforts in event tree analysis, we developed a new software package named ETAP (Event Tree Analysis Supporting Program) for event tree analysis. ETAP is an interactive PC-based program which has the ability to construct, update, document, and quantify event trees. Because of its fast running capability to quantify event trees, use of the EATP program can make it easy to perform the sensitivity studies on a variety of system/containment performance issues. This report provides a user's manual for ETAP, which describes the structure, installation, and use of EATP. This software runs on NEC/PC-9800 or compatible PCs that have a 640 KB memory and MS-DOS 2.11 or higher. (author)

  14. OASIS User Manual

    CERN Document Server

    Bojtar, L

    2009-01-01

    The OASIS system has been operational for years now. After a long development the project has reached a state where the number of features it provides exceeds largely what most of its users knows about. The author felt it was time to write a user manual explaining all the functionality of the viewer application. This document is a user manual, concentrating on the functionality of the viewer from the user’s point of view. There are already documents available on the project’s web site about the technical aspects at http://project-oasis.web.cern.ch/project-oasis/presentations.htm . There was an attempt to produce a tutorial on the viewer, but it didn’t get much further than the table of contents, that however is well thought. The structure of this user manual follows the same principle, the basic and most often used features are grouped together. Advanced or less often used features are described in a separate chapter. There is a second organizational principle, features belong to different levels: chann...

  15. Manually controlled neutron-activation system

    International Nuclear Information System (INIS)

    Johns, R.A.; Carothers, G.A.

    1982-01-01

    A manually controlled neutron activation system, the Manual Reactor Activation System, was designed and built and has been operating at one of the Savannah River Plant's production reactors. With this system, samples can be irradiated for up to 24 hours and pneumatically transferred to a shielded repository for decay until their activity is low enough for them to be handled at a radiobench. The Manual Reactor Activation System was built to provide neutron activation of solid waste forms for the Alternative Waste Forms Leach Testing Program. Neutron activation of the bulk sample prior to leaching permits sensitive multielement radiometric analyses of the leachates

  16. Validity and Reliability of Assessing Body Composition Using a Mobile Application.

    Science.gov (United States)

    Macdonald, Elizabeth Z; Vehrs, Pat R; Fellingham, Gilbert W; Eggett, Dennis; George, James D; Hager, Ronald

    2017-12-01

    The purpose of this study was to determine the validity and reliability of the LeanScreen (LS) mobile application that estimates percent body fat (%BF) using estimates of circumferences from photographs. The %BF of 148 weight-stable adults was estimated once using dual-energy x-ray absorptiometry (DXA). Each of two administrators assessed the %BF of each subject twice using the LS app and manually measured circumferences. A mixed-model ANOVA and Bland-Altman analyses were used to compare the estimates of %BF obtained from each method. Interrater and intrarater reliabilities values were determined using multiple measurements taken by each of the two administrators. The LS app and manually measured circumferences significantly underestimated (P < 0.05) the %BF determined using DXA by an average of -3.26 and -4.82 %BF, respectively. The LS app (6.99 %BF) and manually measured circumferences (6.76 %BF) had large limits of agreement. All interrater and intrarater reliability coefficients of estimates of %BF using the LS app and manually measured circumferences exceeded 0.99. The estimates of %BF from manually measured circumferences and the LS app were highly reliable. However, these field measures are not currently recommended for the assessment of body composition because of significant bias and large limits of agreements.

  17. The Effectiveness of Manual Therapy for Relieving Pain, Stiffness, and Dysfunction in Knee Osteoarthritis: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Xu, Qinguang; Chen, Bei; Wang, Yueyi; Wang, Xuezong; Han, Dapeng; Ding, Daofang; Zheng, Yuxin; Cao, Yuelong; Zhan, Hongsheng; Zhou, Yao

    2017-05-01

    Knee osteoarthritis (KOA) is the most common form of arthritis, leading to pain disability in seniors and increased health care utilization. Manual therapy is one widely used physical treatment for KOA. To evaluate the effectiveness and adverse events (AEs) of manual therapy compared to other treatments for relieving pain, stiffness, and physical dysfunction in patients with KOA. A systematic review and meta-analysis of manual therapy for KOA. We searched PubMed, EMBASE, the Cochrane Library, and Chinese databases for relevant randomized controlled trials (RCTs) of manual therapy for patients with KOA from the inception to October 2015 without language restrictions. RCTs compared manual therapy to the placebo or other interventional control with an appropriate description of randomization. Two reviewers independently conducted the search results identification, data extraction, and methodological quality assessment. The methodological quality was assessed by PEDro scale. Pooled data was expressed as standard mean difference (SMD), with 95% confident intervals (CIs) in a random effects model. The meta-analysis of manual therapy for KOA on pain, stiffness, and physical function were conducted. Fourteen studies involving 841 KOA participants compared to other treatments were included. The methodological quality of most included RCTs was poor. The mean PEDro scale score was 6.6. The meta-analyses results showed that manual therapy had statistically significant effects on relieving pain (standardized mean difference, SMD = -0.61, 95% CI -0.95 to -0.28, P = 76%), stiffness (SMD = -0.58, 95% CI -0.95 to -0.21, P = 81%), improving physical function (SMD = -0.49, 95% CI -0.76 to -0.22, P = 65%), and total score (SMD = -0.56, 95% CI -0.78 to -0.35, P = 50%). But in the subgroups, manual therapy did not show significant improvements on stiffness and physical function when treatment duration was less than 4 weeks. And the long-term information for manual therapy was

  18. Sex differences in confidence influence patterns of conformity.

    Science.gov (United States)

    Cross, Catharine P; Brown, Gillian R; Morgan, Thomas J H; Laland, Kevin N

    2017-11-01

    Lack of confidence in one's own ability can increase the likelihood of relying on social information. Sex differences in confidence have been extensively investigated in cognitive tasks, but implications for conformity have not been directly tested. Here, we tested the hypothesis that, in a task that shows sex differences in confidence, an indirect effect of sex on social information use will also be evident. Participants (N = 168) were administered a mental rotation (MR) task or a letter transformation (LT) task. After providing an answer, participants reported their confidence before seeing the responses of demonstrators and being allowed to change their initial answer. In the MR, but not the LT, task, women showed lower levels of confidence than men, and confidence mediated an indirect effect of sex on the likelihood of switching answers. These results provide novel, experimental evidence that confidence is a general explanatory mechanism underpinning susceptibility to social influences. Our results have implications for the interpretation of the wider literature on sex differences in conformity. © 2016 The British Psychological Society.

  19. Methane measurements manual; Handbok metanmaetningar

    Energy Technology Data Exchange (ETDEWEB)

    Holmgren, Magnus Andreas (SP Technical research institute of Sweden, Boraas (Sweden))

    2011-02-15

    Emissions to air in different parts of the system may arise in biogas plants, where there is biological treatment of organic matter by anaerobic degradation, and during upgrading of biogas to vehicle fuel. There are mainly four reasons why these emissions must be minimized. These are safety, greenhouse gas emissions, economy and smell. This manual gathers experience of several years of work with measurement of methane emissions from biogas and upgrading facilities. This work has been done mainly in the context of Swedish Waste Management's system of voluntary commitment. The purpose of this manual is to standardize methods and procedures when methane measurements are carried out so that the results are comparable between different providers. The main target group of the manual is measurement consultants performing such measurements. Calculation template in Excel is part of the manual, which further contributes to the measurements evaluated in a standardized way. The manual contains several examples which have been calculated in the accompanying Excel template. The handbook also contains a chapter mainly intended for facility staff, in which implementation of accurate leak detection is described, and where there are hints of a system of so-called intermediate inspections to detect leaks in time

  20. Comprehensive Plan for Public Confidence in Nuclear Regulator

    International Nuclear Information System (INIS)

    Choi, Kwang Sik; Choi, Young Sung; Kim, Ho ki

    2008-01-01

    Public confidence in nuclear regulator has been discussed internationally. Public trust or confidence is needed for achieving regulatory goal of assuring nuclear safety to the level that is acceptable by the public or providing public ease for nuclear safety. In Korea, public ease or public confidence has been suggested as major policy goal in the 'Nuclear regulatory policy direction' annually announced. This paper reviews theory of trust, its definitions and defines nuclear safety regulation, elements of public trust or public confidence developed based on the study conducted so far. Public ease model developed and 10 measures for ensuring public confidence are also presented and future study directions are suggested

  1. Simultaneous confidence bands for the integrated hazard function

    OpenAIRE

    Dudek, Anna; Gocwin, Maciej; Leskow, Jacek

    2006-01-01

    The construction of the simultaneous confidence bands for the integrated hazard function is considered. The Nelson--Aalen estimator is used. The simultaneous confidence bands based on bootstrap methods are presented. Two methods of construction of such confidence bands are proposed. The weird bootstrap method is used for resampling. Simulations are made to compare the actual coverage probability of the bootstrap and the asymptotic simultaneous confidence bands. It is shown that the equal--tai...

  2. A proposed framework for computational fluid dynamics code calibration/validation

    International Nuclear Information System (INIS)

    Oberkampf, W.L.

    1993-01-01

    The paper reviews the terminology and methodology that have been introduced during the last several years for building confidence n the predictions from Computational Fluid Dynamics (CID) codes. Code validation terminology developed for nuclear reactor analyses and aerospace applications is reviewed and evaluated. Currently used terminology such as ''calibrated code,'' ''validated code,'' and a ''validation experiment'' is discussed along with the shortcomings and criticisms of these terms. A new framework is proposed for building confidence in CFD code predictions that overcomes some of the difficulties of past procedures and delineates the causes of uncertainty in CFD predictions. Building on previous work, new definitions of code verification and calibration are proposed. These definitions provide more specific requirements for the knowledge level of the flow physics involved and the solution accuracy of the given partial differential equations. As part of the proposed framework, categories are also proposed for flow physics research, flow modeling research, and the application of numerical predictions. The contributions of physical experiments, analytical solutions, and other numerical solutions are discussed, showing that each should be designed to achieve a distinctively separate purpose in building confidence in accuracy of CFD predictions. A number of examples are given for each approach to suggest methods for obtaining the highest value for CFD code quality assurance

  3. User's manual, version 1.00 for Monteburns, version 3.01

    International Nuclear Information System (INIS)

    Poston, D.I.; Trellue, H.R.

    1998-06-01

    Monteburns is a fully automated tool that links the Monte Carlo transport code MCNP with the radioactive decay and burnup code ORIGEN2. Monteburns produces a large number of criticality and burnup results based on various material feed/removal specifications, power(s), and time intervals. The program processes input from the user that specifies the system geometry, initial material compositions, feed/removal specifications, and other code-specific parameters. Various results from MCNP, ORIGEN2, and other calculations are then output successively as the code runs. The principle function of monteburns is to transfer one-group cross section and flux values from MCNP to ORIGEN2, and then transfer the resulting material compositions (after irradiation and/or decay) from ORIGEN2 back to MCNP in a repeated, cyclic fashion. The basic requirement of the code is that the user have a working MCNP input file and other input parameters; all interaction with ORIGEN2 and other calculations are performed by monteburns. This report serves as a user's manual for monteburns. It describes how the code functions, what input the user must provide, the calculations performed by the code, and it presents the format required for input files, as well as samples of these files. Monteburns is still in a developmental stage; thus, additions and/or changes may be made over time, and the user's manual will change as well. This is the first version of the user's manual (valid for monteburns version 3.01); users should contact the authors to inquire if a more recent version is available

  4. Manual on indoor air quality

    International Nuclear Information System (INIS)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues

  5. Manual on indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues.

  6. Beyond hypercorrection: remembering corrective feedback for low-confidence errors.

    Science.gov (United States)

    Griffiths, Lauren; Higham, Philip A

    2018-02-01

    Correcting errors based on corrective feedback is essential to successful learning. Previous studies have found that corrections to high-confidence errors are better remembered than low-confidence errors (the hypercorrection effect). The aim of this study was to investigate whether corrections to low-confidence errors can also be successfully retained in some cases. Participants completed an initial multiple-choice test consisting of control, trick and easy general-knowledge questions, rated their confidence after answering each question, and then received immediate corrective feedback. After a short delay, they were given a cued-recall test consisting of the same questions. In two experiments, we found high-confidence errors to control questions were better corrected on the second test compared to low-confidence errors - the typical hypercorrection effect. However, low-confidence errors to trick questions were just as likely to be corrected as high-confidence errors. Most surprisingly, we found that memory for the feedback and original responses, not confidence or surprise, were significant predictors of error correction. We conclude that for some types of material, there is an effortful process of elaboration and problem solving prior to making low-confidence errors that facilitates memory of corrective feedback.

  7. EVLncRNAs: a manually curated database for long non-coding RNAs validated by low-throughput experiments

    Science.gov (United States)

    Zhao, Huiying; Yu, Jiafeng; Guo, Chengang; Dou, Xianghua; Song, Feng; Hu, Guodong; Cao, Zanxia; Qu, Yuanxu

    2018-01-01

    Abstract Long non-coding RNAs (lncRNAs) play important functional roles in various biological processes. Early databases were utilized to deposit all lncRNA candidates produced by high-throughput experimental and/or computational techniques to facilitate classification, assessment and validation. As more lncRNAs are validated by low-throughput experiments, several databases were established for experimentally validated lncRNAs. However, these databases are small in scale (with a few hundreds of lncRNAs only) and specific in their focuses (plants, diseases or interactions). Thus, it is highly desirable to have a comprehensive dataset for experimentally validated lncRNAs as a central repository for all of their structures, functions and phenotypes. Here, we established EVLncRNAs by curating lncRNAs validated by low-throughput experiments (up to 1 May 2016) and integrating specific databases (lncRNAdb, LncRANDisease, Lnc2Cancer and PLNIncRBase) with additional functional and disease-specific information not covered previously. The current version of EVLncRNAs contains 1543 lncRNAs from 77 species that is 2.9 times larger than the current largest database for experimentally validated lncRNAs. Seventy-four percent lncRNA entries are partially or completely new, comparing to all existing experimentally validated databases. The established database allows users to browse, search and download as well as to submit experimentally validated lncRNAs. The database is available at http://biophy.dzu.edu.cn/EVLncRNAs. PMID:28985416

  8. Manual for reactor produced radioisotopes

    International Nuclear Information System (INIS)

    2003-01-01

    Radioisotopes find extensive applications in several fields including medicine, industry, agriculture and research. Radioisotope production to service different sectors of economic significance constitutes an important ongoing activity of many national nuclear programmes. Radioisotopes, formed by nuclear reactions on targets in a reactor or cyclotron, require further processing in almost all cases to obtain them in a form suitable for use. Specifications for final products and testing procedures for ensuring quality are also an essential part of a radioisotope production programme. The International Atomic Energy Agency (IAEA) has compiled and published such information before for the benefit of laboratories of Member States. The first compilation, entitled Manual of Radioisotope Production, was published in 1966 (Technical Reports Series No. 63). A more elaborate and comprehensive compilation, entitled Radioisotope Production and Quality Control, was published in 1971 (Technical Reports Series No. 128). Both served as useful reference sources for scientists working in radioisotope production worldwide. The 1971 publication has been out of print for quite some time. The IAEA convened a consultants meeting to consider the need for compiling an updated manual. The consultants recommended the publication of an updated manual taking the following into consideration: significant changes have taken place since 1971 in many aspects of radioisotope production; many radioisotopes have been newly introduced while many others have become gradually obsolete; considerable experience and knowledge have been gained in production of important radioisotopes over the years, which can be preserved through compilation of the manual; there is still a need for a comprehensive manual on radioisotope production methods for new entrants to the field, and as a reference. It was also felt that updating all the subjects covered in the 1971 manual at a time may not be practical considering the

  9. 21 CFR 868.1030 - Manual algesimeter.

    Science.gov (United States)

    2010-04-01

    ... DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1030 Manual algesimeter. (a) Identification. A manual algesimeter is a mechanical device intended to determine a patient's sensitivity to pain after...

  10. Maternal Confidence for Physiologic Childbirth: A Concept Analysis.

    Science.gov (United States)

    Neerland, Carrie E

    2018-06-06

    Confidence is a term often used in research literature and consumer media in relation to birth, but maternal confidence has not been clearly defined, especially as it relates to physiologic labor and birth. The aim of this concept analysis was to define maternal confidence in the context of physiologic labor and childbirth. Rodgers' evolutionary method was used to identify attributes, antecedents, and consequences of maternal confidence for physiologic birth. Databases searched included Ovid MEDLINE, CINAHL, PsycINFO, and Sociological Abstracts from the years 1995 to 2015. A total of 505 articles were retrieved, using the search terms pregnancy, obstetric care, prenatal care, and self-efficacy and the keyword confidence. Articles were identified for in-depth review and inclusion based on whether the term confidence was used or assessed in relationship to labor and/or birth. In addition, a hand search of the reference lists of the selected articles was performed. Twenty-four articles were reviewed in this concept analysis. We define maternal confidence for physiologic birth as a woman's belief that physiologic birth can be achieved, based on her view of birth as a normal process and her belief in her body's innate ability to birth, which is supported by social support, knowledge, and information founded on a trusted relationship with a maternity care provider in an environment where the woman feels safe. This concept analysis advances the concept of maternal confidence for physiologic birth and provides new insight into how women's confidence for physiologic birth might be enhanced during the prenatal period. Further investigation of confidence for physiologic birth across different cultures is needed to identify cultural differences in constructions of the concept. © 2018 by the American College of Nurse-Midwives.

  11. Cupping Therapy Simulation Course; A Pilot Study Assessing Self Reporting of Confidence, Expectations/Satisfaction and Performance

    OpenAIRE

    Aboushanab, Tamer; Khalil, Mohammed; El-Olemy, Ahmed; Alsanad, Saud

    2017-01-01

    This paper aimed to assess self-reporting of confidence, expectations/satisfaction, and performance of medical students before and after the cupping therapy simulation training course and to validate cupping simulation training evaluation questionnaire (CSTEQ). It was a pilot study to evaluate cupping therapy simulation course provided by National Center for Complementary and Alternative Medicine (NCCAM).  The number of participants was 29/41 (70.7%) (20 females and 9 males) before train...

  12. Self-Confidence in the Hospitality Industry

    Directory of Open Access Journals (Sweden)

    Michael Oshins

    2014-02-01

    Full Text Available Few industries rely on self-confidence to the extent that the hospitality industry does because guests must feel welcome and that they are in capable hands. This article examines the results of hundreds of student interviews with industry professionals at all levels to determine where the majority of the hospitality industry gets their self-confidence.

  13. 21 CFR 868.5915 - Manual emergency ventilator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual emergency ventilator. 868.5915 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5915 Manual emergency ventilator. (a) Identification. A manual emergency ventilator is a device, usually incorporating a bag and valve, intended to...

  14. Dental Chairside Technique. Student's Manual.

    Science.gov (United States)

    Apfel, Maura; Weaver, Trudy Karlene

    This manual is part of a series dealing with skills and information needed by students in dental assisting. The individualized student materials are suitable for classroom, laboratory, or cooperative training programs. This student manual contains four units covering the following topics: local anesthesia; dental office emergencies; oral hygiene;…

  15. Nuclear material operations manual

    International Nuclear Information System (INIS)

    Tyler, R.P.

    1981-02-01

    This manual provides a concise and comprehensive documentation of the operating procedures currently practiced at Sandia National Laboratories with regard to the management, control, and accountability of nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations-management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of playscripts in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  16. Nuclear material operations manuals

    International Nuclear Information System (INIS)

    Tyler, R.P.

    1979-06-01

    This manual is intended to provide a concise and comprehensive documentation of the operating procedures currently practiced at Sandia Laboratories with regard to the management, control, and accountability of radioactive and nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations-management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of playscripts in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  17. Manual vs. computer-assisted sperm analysis: can CASA replace manual assessment of human semen in clinical practice?

    Science.gov (United States)

    Talarczyk-Desole, Joanna; Berger, Anna; Taszarek-Hauke, Grażyna; Hauke, Jan; Pawelczyk, Leszek; Jedrzejczak, Piotr

    2017-01-01

    The aim of the study was to check the quality of computer-assisted sperm analysis (CASA) system in comparison to the reference manual method as well as standardization of the computer-assisted semen assessment. The study was conducted between January and June 2015 at the Andrology Laboratory of the Division of Infertility and Reproductive Endocrinology, Poznań University of Medical Sciences, Poland. The study group consisted of 230 men who gave sperm samples for the first time in our center as part of an infertility investigation. The samples underwent manual and computer-assisted assessment of concentration, motility and morphology. A total of 184 samples were examined twice: manually, according to the 2010 WHO recommendations, and with CASA, using the program set-tings provided by the manufacturer. Additionally, 46 samples underwent two manual analyses and two computer-assisted analyses. The p-value of p CASA and manually. In the group of patients where all analyses with each method were performed twice on the same sample we found no significant differences between both assessments of the same probe, neither in the samples analyzed manually nor with CASA, although standard deviation was higher in the CASA group. Our results suggest that computer-assisted sperm analysis requires further improvement for a wider application in clinical practice.

  18. ADAM SMITH: THE INVISIBLE HAND OR CONFIDENCE

    Directory of Open Access Journals (Sweden)

    Fernando Luis, Gache

    2010-01-01

    Full Text Available In 1776 Adam Smith raised the matter that an invisible hand was the one which moved the markets to obtain its efficiency. Despite in the present paper we are going to raise the hypothesis, that this invisible hand is in fact the confidence that each person feels when he is going to do business. That in addition it is unique, because it is different from the confidence of the others and that is a variable nonlinear that essentially is ligatured to respective personal histories. For that we are going to take as its bases the paper by Leopoldo Abadía (2009, with respect to the financial economy crisis that happened in 2007-2008, to evidence the form in which confidence operates. Therefore the contribution that we hope to do with this paper is to emphasize that, the level of confidence of the different actors, is the one which really moves the markets, (therefore the economy and that the crisis of the subprime mortgages is a confidence crisis at world-wide level.

  19. Geothermal reservoir assessment manual; 1984-1992 nendo chinetsu choryusou hyoka shuhou manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    A geothermal reservoir assessment manual was prepared for the promotion of the development of geothermal power generation, based on the results of the 'geothermal reservoir assessment technique development project' implemented during the fiscal 1984-1992 period and on the results of surveys conducted in Japan and abroad. Of the geothermal systems generally classified into the steam dominant type and the hot water dominant type, encounters with the steam dominant type are but seldom reported. This manual therefore covers the hot water dominant type only. In addition to the explanation of the basic concept and the outline of geothermal reservoirs, the manual carries data necessary for reservoir assessment; geological and geophysical data analyses; geochemistry in reservoir assessment; data of underground logging and of fuming; conceptual models; simulators and models for reservoir simulation; natural-state simulation, history-matching simulation, and reservoir behavior predicting simulation; case history (modeling of a geothermal reservoir prior to exploitation), references, and so forth. (NEDO)

  20. Geothermal reservoir assessment manual; 1984-1992 nendo chinetsu choryusou hyoka shuhou manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    A geothermal reservoir assessment manual was prepared for the promotion of the development of geothermal power generation, based on the results of the 'geothermal reservoir assessment technique development project' implemented during the fiscal 1984-1992 period and on the results of surveys conducted in Japan and abroad. Of the geothermal systems generally classified into the steam dominant type and the hot water dominant type, encounters with the steam dominant type are but seldom reported. This manual therefore covers the hot water dominant type only. In addition to the explanation of the basic concept and the outline of geothermal reservoirs, the manual carries data necessary for reservoir assessment; geological and geophysical data analyses; geochemistry in reservoir assessment; data of underground logging and of fuming; conceptual models; simulators and models for reservoir simulation; natural-state simulation, history-matching simulation, and reservoir behavior predicting simulation; case history (modeling of a geothermal reservoir prior to exploitation), references, and so forth. (NEDO)

  1. Light-water-reactor hydrogen manual

    International Nuclear Information System (INIS)

    Camp, A.L.; Cummings, J.C.; Sherman, M.P.; Kupiec, C.F.; Healy, R.J.; Caplan, J.S.; Sandhop, J.R.; Saunders, J.H.

    1983-06-01

    A manual concerning the behavior of hydrogen in light water reactors has been prepared. Both normal operations and accident situations are addressed. Topics considered include hydrogen generation, transport and mixing, detection, and combustion, and mitigation. Basic physical and chemical phenomena are described, and plant-specific examples are provided where appropriate. A wide variety of readers, including operators, designers, and NRC staff, will find parts of this manual useful. Different sections are written at different levels, according to the most likely audience. The manual is not intended to provide specific plant procedures, but rather, to provide general guidance that may assist in the development of such procedures

  2. 21 CFR 872.6855 - Manual toothbrush.

    Science.gov (United States)

    2010-04-01

    ... remove adherent plaque and food debris from the teeth to reduce tooth decay. (b) Classification. Class I... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6855 Manual toothbrush. (a) Identification. A manual...

  3. Nuclear structure references coding manual

    International Nuclear Information System (INIS)

    Ramavataram, S.; Dunford, C.L.

    1984-02-01

    This manual is intended as a guide to Nuclear Structure References (NSR) compilers. The basic conventions followed at the National Nuclear Data Center (NNDC), which are compatible with the maintenance and updating of and retrieval from the Nuclear Structure References (NSR) file, are outlined. The structure of the NSR file such as the valid record identifiers, record contents, text fields as well as the major topics for which [KEYWORDS] are prepared are ennumerated. Relevant comments regarding a new entry into the NSR file, assignment of [KEYNO ], generation of [SELECTRS] and linkage characteristics are also given. A brief definition of the Keyword abstract is given followed by specific examples; for each TOPIC, the criteria for inclusion of an article as an entry into the NSR file as well as coding procedures are described. Authors submitting articles to Journals which require Keyword abstracts should follow the illustrations. The scope of the literature covered at NNDC, the categorization into Primary and Secondary sources, etc. is discussed. Useful information regarding permitted character sets, recommended abbreviations, etc. is given

  4. 14 CFR 125.75 - Airplane flight manual.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane flight manual. 125.75 Section 125... OPERATIONS: AIRPLANES HAVING A SEATING CAPACITY OF 20 OR MORE PASSENGERS OR A MAXIMUM PAYLOAD CAPACITY OF 6... Airplane flight manual. (a) Each certificate holder shall keep a current approved Airplane Flight Manual or...

  5. Desalination Economic Evaluation Program (DEEP). User's manual

    International Nuclear Information System (INIS)

    2000-01-01

    DEEP (formerly named ''Co-generation and Desalination Economic Evaluation'' Spreadsheet, CDEE) has been developed originally by General Atomics under contract, and has been used in the IAEA's feasibility studies. For further confidence in the software, it was validated in March 1998. After that, a user friendly version has been issued under the name of DEEP at the end of 1998. DEEP output includes the levelised cost of water and power, a breakdown of cost components, energy consumption and net saleable power for each selected option. Specific power plants can be modelled by adjustment of input data including design power, power cycle parameters and costs

  6. Kinesiology Workbook and Laboratory Manual.

    Science.gov (United States)

    Harris, Ruth W.

    This manual is written for students in anatomy, kinesiology, or introductory biomechanics courses. The book is divided into two sections, a kinesiology workbook and a laboratory manual. The two sections parallel each other in content and format. Each is divided into three corresponding sections: (1) Anatomical bases for movement description; (2)…

  7. Trust, confidence, and the 2008 global financial crisis.

    Science.gov (United States)

    Earle, Timothy C

    2009-06-01

    The 2008 global financial crisis has been compared to a "once-in-a-century credit tsunami," a disaster in which the loss of trust and confidence played key precipitating roles and the recovery from which will require the restoration of these crucial factors. Drawing on the analogy between the financial crisis and environmental and technological hazards, recent research on the role of trust and confidence in the latter is used to provide a perspective on the former. Whereas "trust" and "confidence" are used interchangeably and without explicit definition in most discussions of the financial crisis, this perspective uses the TCC model of cooperation to clearly distinguish between the two and to demonstrate how this distinction can lead to an improved understanding of the crisis. The roles of trust and confidence-both in precipitation and in possible recovery-are discussed for each of the three major sets of actors in the crisis, the regulators, the banks, and the public. The roles of trust and confidence in the larger context of risk management are also examined; trust being associated with political approaches, confidence with technical. Finally, the various stances that government can take with regard to trust-such as supportive or skeptical-are considered. Overall, it is argued that a clear understanding of trust and confidence and a close examination of the specific, concrete circumstances of a crisis-revealing when either trust or confidence is appropriate-can lead to useful insights for both recovery and prevention of future occurrences.

  8. Tank waste remediation system process engineering instruction manual

    International Nuclear Information System (INIS)

    ADAMS, M.R.

    1998-01-01

    The purpose of the Tank Waste Remediation System (TWRS) Process Engineering Instruction Manual is to provide guidance and direction to TWRS Process Engineering staff regarding conduct of business. The objective is to establish a disciplined and consistent approach to business such that the work processes within TWRS Process Engineering are safe, high quality, disciplined, efficient, and consistent with Lockheed Martin Hanford Corporation Policies and Procedures. The sections within this manual are of two types: for compliance and for guidance. For compliance sections are intended to be followed per-the-letter until such time as they are formally changed per Section 2.0 of this manual. For guidance sections are intended to be used by the staff for guidance in the conduct of work where technical judgment and discernment are required. The guidance sections shall also be changed per Section 2.0 of this manual. The required header for each manual section is illustrated in Section 2.0, Manual Change Control procedure. It is intended that this manual be used as a training and indoctrination resource for employees of the TWRS Process Engineering organization. The manual shall be required reading for all TWRS Process Engineering staff, matrixed, and subcontracted employees

  9. Radiology Aide. Instructor Key [and] Student Manual.

    Science.gov (United States)

    Hartwein, Jon; Dunham, John

    This manual can be used independently by students in secondary health occupations programs or by persons receiving on-the-job training in a radiology department. The manual includes an instructor's key that provides answers to the activity sheets and unit evaluations. The manual consists of the following five units: (1) orientation to radiology;…

  10. Age-related differences in regional brain volumes: A comparison of optimized voxel-based morphometry to manual volumetry

    Science.gov (United States)

    Kennedy, Kristen M.; Erickson, Kirk I.; Rodrigue, Karen M.; Voss, Michelle W.; Colcombe, Stan J.; Kramer, Arthur F.; Acker, James D.; Raz, Naftali

    2009-01-01

    Regional manual volumetry is the gold standard of in vivo neuroanatomy, but is labor-intensive, can be imperfectly reliable, and allows for measuring limited number of regions. Voxel-based morphometry (VBM) has perfect repeatability and assesses local structure across the whole brain. However, its anatomic validity is unclear, and with its increasing popularity, a systematic comparison of VBM to manual volumetry is necessary. The few existing comparison studies are limited by small samples, qualitative comparisons, and limited selection and modest reliability of manual measures. Our goal was to overcome those limitations by quantitatively comparing optimized VBM findings with highly reliable multiple regional measures in a large sample (N = 200) across a wide agespan (18–81). We report a complex pattern of similarities and differences. Peak values of VBM volume estimates (modulated density) produced stronger age differences and a different spatial distribution from manual measures. However, when we aggregated VBM-derived information across voxels contained in specific anatomically defined regions (masks), the patterns of age differences became more similar, although important discrepancies emerged. Notably, VBM revealed stronger age differences in the regions bordering CSF and white matter areas prone to leukoaraiosis, and VBM was more likely to report nonlinearities in age-volume relationships. In the white matter regions, manual measures showed stronger negative associations with age than the corresponding VBM-based masks. We conclude that VBM provides realistic estimates of age differences in the regional gray matter only when applied to anatomically defined regions, but overestimates effects when individual peaks are interpreted. It may be beneficial to use VBM as a first-pass strategy, followed by manual measurement of anatomically-defined regions. PMID:18276037

  11. Nuclear material operations manual

    International Nuclear Information System (INIS)

    Tyler, R.P.; Gassman, L.D.

    1978-04-01

    This manual is intended to provide a concise and comprehensive documentation of the operating procedures currently practiced at Sandia Laboratories with regard to the management, control, and accountability of radioactive and nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations--management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of ''play-scripts'' in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  12. WAM-E user's manual

    International Nuclear Information System (INIS)

    Rayes, L.G.; Riley, J.E.

    1986-07-01

    The WAM-E series of mainframe computer codes have been developed to efficiently analyze the large binary models (e.g., fault trees) used to represent the logic relationships within and between the systems of a nuclear power plant or other large, multisystem entity. These codes have found wide application in reliability and safety studies of nuclear power plant systems. There are now nine codes in the WAM-E series, with six (WAMBAM/WAMTAP, WAMCUT, WAMCUT-II, WAMFM, WAMMRG, and SPASM) classified as Type A Production codes and the other three (WAMFTP, WAMTOP, and WAMCONV) classified as Research codes. This document serves as a combined User's Guide, Programmer's Manual, and Theory Reference for the codes, with emphasis on the Production codes. To that end, the manual is divided into four parts: Part I, Introduction; Part II, Theory and Numerics; Part III, WAM-E User's Guide; and Part IV, WAMMRG Programmer's Manual

  13. Spacecraft early design validation using formal methods

    International Nuclear Information System (INIS)

    Bozzano, Marco; Cimatti, Alessandro; Katoen, Joost-Pieter; Katsaros, Panagiotis; Mokos, Konstantinos; Nguyen, Viet Yen; Noll, Thomas; Postma, Bart; Roveri, Marco

    2014-01-01

    The size and complexity of software in spacecraft is increasing exponentially, and this trend complicates its validation within the context of the overall spacecraft system. Current validation methods are labor-intensive as they rely on manual analysis, review and inspection. For future space missions, we developed – with challenging requirements from the European space industry – a novel modeling language and toolset for a (semi-)automated validation approach. Our modeling language is a dialect of AADL and enables engineers to express the system, the software, and their reliability aspects. The COMPASS toolset utilizes state-of-the-art model checking techniques, both qualitative and probabilistic, for the analysis of requirements related to functional correctness, safety, dependability and performance. Several pilot projects have been performed by industry, with two of them having focused on the system-level of a satellite platform in development. Our efforts resulted in a significant advancement of validating spacecraft designs from several perspectives, using a single integrated system model. The associated technology readiness level increased from level 1 (basic concepts and ideas) to early level 4 (laboratory-tested)

  14. 49 CFR 1103.23 - Confidences of a client.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Confidences of a client. 1103.23 Section 1103.23... Responsibilities Toward A Client § 1103.23 Confidences of a client. (a) The practitioner's duty to preserve his client's confidence outlasts the practitioner's employment by the client, and this duty extends to the...

  15. Estimation of rumen microbial protein production from purine derivatives in urine. A laboratory manual for the FAO/IAEA co-ordinated research programme on development, standardization and validation of nuclear based technologies for measuring microbial protein supply in ruminant livestock for improving productivity

    International Nuclear Information System (INIS)

    1997-05-01

    This laboratory manual contains the methodologies used in the standardization and validation of the urine purine derivative technique for estimating microbial protein supply to the rumen. It includes descriptions of methods that involve both radioactive and stable isotopes as well as non isotopic techniques such as chemical assays, since it has been recognised that while isotopic trace techniques provide a powerful tool for nutrition research they can not and should not be used in isolation. Refs, figs, tabs

  16. Confidence assessment. Site-descriptive modelling SDM-Site Laxemar

    International Nuclear Information System (INIS)

    2009-06-01

    The objective of this report is to assess the confidence that can be placed in the Laxemar site descriptive model, based on the information available at the conclusion of the surface-based investigations (SDM-Site Laxemar). In this exploration, an overriding question is whether remaining uncertainties are significant for repository engineering design or long-term safety assessment and could successfully be further reduced by more surface-based investigations or more usefully by explorations underground made during construction of the repository. Procedures for this assessment have been progressively refined during the course of the site descriptive modelling, and applied to all previous versions of the Forsmark and Laxemar site descriptive models. They include assessment of whether all relevant data have been considered and understood, identification of the main uncertainties and their causes, possible alternative models and their handling, and consistency between disciplines. The assessment then forms the basis for an overall confidence statement. The confidence in the Laxemar site descriptive model, based on the data available at the conclusion of the surface based site investigations, has been assessed by exploring: - Confidence in the site characterization data base, - remaining issues and their handling, - handling of alternatives, - consistency between disciplines and - main reasons for confidence and lack of confidence in the model. Generally, the site investigation database is of high quality, as assured by the quality procedures applied. It is judged that the Laxemar site descriptive model has an overall high level of confidence. Because of the relatively robust geological model that describes the site, the overall confidence in the Laxemar Site Descriptive model is judged to be high, even though details of the spatial variability remain unknown. The overall reason for this confidence is the wide spatial distribution of the data and the consistency between

  17. Confidence assessment. Site-descriptive modelling SDM-Site Laxemar

    Energy Technology Data Exchange (ETDEWEB)

    2008-12-15

    The objective of this report is to assess the confidence that can be placed in the Laxemar site descriptive model, based on the information available at the conclusion of the surface-based investigations (SDM-Site Laxemar). In this exploration, an overriding question is whether remaining uncertainties are significant for repository engineering design or long-term safety assessment and could successfully be further reduced by more surface-based investigations or more usefully by explorations underground made during construction of the repository. Procedures for this assessment have been progressively refined during the course of the site descriptive modelling, and applied to all previous versions of the Forsmark and Laxemar site descriptive models. They include assessment of whether all relevant data have been considered and understood, identification of the main uncertainties and their causes, possible alternative models and their handling, and consistency between disciplines. The assessment then forms the basis for an overall confidence statement. The confidence in the Laxemar site descriptive model, based on the data available at the conclusion of the surface based site investigations, has been assessed by exploring: - Confidence in the site characterization data base, - remaining issues and their handling, - handling of alternatives, - consistency between disciplines and - main reasons for confidence and lack of confidence in the model. Generally, the site investigation database is of high quality, as assured by the quality procedures applied. It is judged that the Laxemar site descriptive model has an overall high level of confidence. Because of the relatively robust geological model that describes the site, the overall confidence in the Laxemar Site Descriptive model is judged to be high, even though details of the spatial variability remain unknown. The overall reason for this confidence is the wide spatial distribution of the data and the consistency between

  18. Is STAPLE algorithm confident to assess segmentation methods in PET imaging?

    International Nuclear Information System (INIS)

    Dewalle-Vignion, Anne-Sophie; Betrouni, Nacim; Vermandel, Maximilien; Baillet, Clio

    2015-01-01

    Accurate tumor segmentation in [18F]-fluorodeoxyglucose positron emission tomography is crucial for tumor response assessment and target volume definition in radiation therapy. Evaluation of segmentation methods from clinical data without ground truth is usually based on physicians’ manual delineations. In this context, the simultaneous truth and performance level estimation (STAPLE) algorithm could be useful to manage the multi-observers variability. In this paper, we evaluated how this algorithm could accurately estimate the ground truth in PET imaging.Complete evaluation study using different criteria was performed on simulated data. The STAPLE algorithm was applied to manual and automatic segmentation results. A specific configuration of the implementation provided by the Computational Radiology Laboratory was used.Consensus obtained by the STAPLE algorithm from manual delineations appeared to be more accurate than manual delineations themselves (80% of overlap). An improvement of the accuracy was also observed when applying the STAPLE algorithm to automatic segmentations results.The STAPLE algorithm, with the configuration used in this paper, is more appropriate than manual delineations alone or automatic segmentations results alone to estimate the ground truth in PET imaging. Therefore, it might be preferred to assess the accuracy of tumor segmentation methods in PET imaging. (paper)

  19. Is STAPLE algorithm confident to assess segmentation methods in PET imaging?

    Science.gov (United States)

    Dewalle-Vignion, Anne-Sophie; Betrouni, Nacim; Baillet, Clio; Vermandel, Maximilien

    2015-12-01

    Accurate tumor segmentation in [18F]-fluorodeoxyglucose positron emission tomography is crucial for tumor response assessment and target volume definition in radiation therapy. Evaluation of segmentation methods from clinical data without ground truth is usually based on physicians’ manual delineations. In this context, the simultaneous truth and performance level estimation (STAPLE) algorithm could be useful to manage the multi-observers variability. In this paper, we evaluated how this algorithm could accurately estimate the ground truth in PET imaging. Complete evaluation study using different criteria was performed on simulated data. The STAPLE algorithm was applied to manual and automatic segmentation results. A specific configuration of the implementation provided by the Computational Radiology Laboratory was used. Consensus obtained by the STAPLE algorithm from manual delineations appeared to be more accurate than manual delineations themselves (80% of overlap). An improvement of the accuracy was also observed when applying the STAPLE algorithm to automatic segmentations results. The STAPLE algorithm, with the configuration used in this paper, is more appropriate than manual delineations alone or automatic segmentations results alone to estimate the ground truth in PET imaging. Therefore, it might be preferred to assess the accuracy of tumor segmentation methods in PET imaging.

  20. Managerial Accounting. Course Administrative Manual.

    Science.gov (United States)

    Central Michigan Univ., Mount Pleasant. Inst. for Personal and Career Development.

    This manual is part of the materials for a college-level programmed course in managerial accounting and intended to aid instructors in helping students to work their way through the self-instructional study guide around which the course is organized. The manual describes the various materials and components used in the self-instructional sequence…

  1. The development of practice manual for LSC based on job analysis in radiation measurement and analysis

    International Nuclear Information System (INIS)

    Shin, W H; Park, T J

    2017-01-01

    Radiation technology is closely related to the industrial growth and the creation of employment in Korea. The techniques as radiation or/and radioactivity measurement, and the practical skills achieving a higher level analysis are required. In this study, practice manual for liquid scintillation counter were developed by job analysis. Raw data applied in job analysis are collected by on/off line survey by 420 workers employed in KOREA. Importance-priority analysis was performed to make duties and competency unit that consists of knowledge, skills as each task. Refined data was reviewed by expert who experienced actual duties on site. Classification was conducted by focus group interview to deduct duties and competency unit. From the radiation devices in measurement and analysis, liquid scintillation counter was preferentially selected because of the high demands for training. Investigation of build-up status to liquid scintillation counter in KOREA was conducted. Then technical specification and operating procedure of 2 main devices were analyzed and integrated by practice manual. Duties and competency unit were applied to integrated materials respectively. To validate effectiveness, test curriculum was designed by the advanced course to workers who engaged in radiation measurement and analysis. The developed manual is structured to take advantage of test training. This manual will be a practical handbook that can improve the knowledge, skills of radiation workers in Korea. (paper)

  2. The development of practice manual for LSC based on job analysis in radiation measurement and analysis

    Science.gov (United States)

    Shin, W. H.; Park, T. J.

    2017-06-01

    Radiation technology is closely related to the industrial growth and the creation of employment in Korea. The techniques as radiation or/and radioactivity measurement, and the practical skills achieving a higher level analysis are required. In this study, practice manual for liquid scintillation counter were developed by job analysis. Raw data applied in job analysis are collected by on/off line survey by 420 workers employed in KOREA. Importance-priority analysis was performed to make duties and competency unit that consists of knowledge, skills as each task. Refined data was reviewed by expert who experienced actual duties on site. Classification was conducted by focus group interview to deduct duties and competency unit. From the radiation devices in measurement and analysis, liquid scintillation counter was preferentially selected because of the high demands for training. Investigation of build-up status to liquid scintillation counter in KOREA was conducted. Then technical specification and operating procedure of 2 main devices were analyzed and integrated by practice manual. Duties and competency unit were applied to integrated materials respectively. To validate effectiveness, test curriculum was designed by the advanced course to workers who engaged in radiation measurement and analysis. The developed manual is structured to take advantage of test training. This manual will be a practical handbook that can improve the knowledge, skills of radiation workers in Korea.

  3. High Confidence Software and Systems Research Needs

    Data.gov (United States)

    Networking and Information Technology Research and Development, Executive Office of the President — This White Paper presents a survey of high confidence software and systems research needs. It has been prepared by the High Confidence Software and Systems...

  4. Confidence in Alternative Dispute Resolution: Experience from Switzerland

    Directory of Open Access Journals (Sweden)

    Christof Schwenkel

    2014-06-01

    Full Text Available Alternative Dispute Resolution plays a crucial role in the justice system of Switzerland. With the unified Swiss Code of Civil Procedure, it is required that each litigation session shall be preceded by an attempt at conciliation before a conciliation authority. However, there has been little research on conciliation authorities and the public's perception of the authorities. This paper looks at public confidence in conciliation authorities and provides results of a survey conducted with more than 3,400 participants. This study found that public confidence in Swiss conciliation authorities is generally high, exceeds the ratings for confidence in cantonal governments and parliaments, but is lower than confidence in courts.Since the institutional models of the conciliation authorities (meaning the organization of the authorities and the selection of the conciliators differ widely between the 26 Swiss cantons, the influence of the institutional models on public confidence is analyzed. Contrary to assumptions based on New Institutional-ism approaches, this study reports that the institutional models do not impact public confidence. Also, the relationship between a participation in an election of justices of the peace or conciliators and public confidence in these authorities is found to be at most very limited (and negative. Similar to common findings on courts, the results show that general contacts with conciliation authorities decrease public confidence in these institutions whereas a positive experience with a conciliation authority leads to more confidence.The Study was completed as part of the research project 'Basic Research into Court Management in Switzerland', supported by the Swiss National Science Foundation (SNSF. Christof Schwenkel is a PhD student at the University of Lucerne and a research associate and project manager at Interface Policy Studies. A first version of this article was presented at the 2013 European Group for Public

  5. Food skills confidence and household gatekeepers' dietary practices.

    Science.gov (United States)

    Burton, Melissa; Reid, Mike; Worsley, Anthony; Mavondo, Felix

    2017-01-01

    Household food gatekeepers have the potential to influence the food attitudes and behaviours of family members, as they are mainly responsible for food-related tasks in the home. The aim of this study was to determine the role of gatekeepers' confidence in food-related skills and nutrition knowledge on food practices in the home. An online survey was completed by 1059 Australian dietary gatekeepers selected from the Global Market Insite (GMI) research database. Participants responded to questions about food acquisition and preparation behaviours, the home eating environment, perceptions and attitudes towards food, and demographics. Two-step cluster analysis was used to identify groups based on confidence regarding food skills and nutrition knowledge. Chi-square tests and one-way ANOVAs were used to compare the groups on the dependent variables. Three groups were identified: low confidence, moderate confidence and high confidence. Gatekeepers in the highest confidence group were significantly more likely to report lower body mass index (BMI), and indicate higher importance of fresh food products, vegetable prominence in meals, product information use, meal planning, perceived behavioural control and overall diet satisfaction. Gatekeepers in the lowest confidence group were significantly more likely to indicate more perceived barriers to healthy eating, report more time constraints and more impulse purchasing practices, and higher convenience ingredient use. Other smaller associations were also found. Household food gatekeepers with high food skills confidence were more likely to engage in several healthy food practices, while those with low food skills confidence were more likely to engage in unhealthy food practices. Food education strategies aimed at building food-skills and nutrition knowledge will enable current and future gatekeepers to make healthier food decisions for themselves and for their families. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. NV/YMP RADIOLOGICAL CONTROL MANUAL

    Energy Technology Data Exchange (ETDEWEB)

    U.S. DEPARTMENT OF ENERGY, NATIONAL NUCLEAR SECURITY ADMINISTRATION NEVADA SITE OFFICE; BECHTEL NEVADA

    2004-11-01

    This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) and the Yucca Mountain Office of Repository Development (YMORD). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations Part 835 (10 CFR 835), Occupational Radiation Protection. Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Pleasanton, California; and at Andrews Air Force Base, Maryland. In addition, field work by NNSA/NSO at other locations is also covered by this manual.

  7. NV/YMP RADIOLOGICAL CONTROL MANUAL

    International Nuclear Information System (INIS)

    2004-01-01

    This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) and the Yucca Mountain Office of Repository Development (YMORD). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations Part 835 (10 CFR 835), Occupational Radiation Protection. Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Pleasanton, California; and at Andrews Air Force Base, Maryland. In addition, field work by NNSA/NSO at other locations is also covered by this manual

  8. Radiological Control Manual. Revision 0, January 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  9. Users Manual for the FEHMN application

    International Nuclear Information System (INIS)

    Zyvoloski, G.A.; Robinson, B.A.; Dash, Z.V.; Trease, L.L.

    1996-01-01

    The user's manual documents the use of the Yucca Mountain Site Characterization Projects Finite element heat and mass transfer code (FEHMN) application. The manual covers: Program considerations, data files, input data, output, system interface, and examples

  10. Manual handling incident claims in the healthcare sector: Factors and outcomes.

    Science.gov (United States)

    Dockrell, Sara; Johnson, Muriel; Ganly, Joe; Bennett, Kathleen

    2011-01-01

    Manual handling (MH) incidents may result in injury, absenteeism and/or compensation claim. This study investigated the factors associated with MH incidents among healthcare workers who had made a claim, and the management and outcome of those workers. A national sample of healthcare sector MH incident claim files (n=247) were accessed and 35~files met the inclusion criteria. Data were collected and presented graphically or descriptively using percentages (and 95% Confidence intervals, CI). Chi-square (χ2) tests were used for comparing proportions between groups. SPSS (v14.0) was used for analysis. Significance at p 52 weeks. Only 58% (49%, 65%) returned to work. Claimants who had been in communication with employers were significantly more likely to return to work than those who did not (χ2 test, p=0.017). Improved management of MH incidents and injured workers are recommended.

  11. LLCEDATA and LLCECALC for Windows version 1.0, Volume 1: User's manual

    International Nuclear Information System (INIS)

    McFadden, J.G.

    1998-01-01

    LLCEDATA and LLCECALC for Windows are user-friendly computer software programs that work together to determine the proper waste designation, handling, and disposition requirements for Long Length Contaminated Equipment (LLCE). LLCEDATA reads from a variety of data bases to produce an equipment data file (EDF) that represents a snapshot of both the LLCE and the tank it originates from. LLCECALC reads the EDF and a gamma assay (AV2) file that is produced by the Flexible Receiver Gamma Energy Analysis System. LLCECALC performs corrections to the AV2 file as it is being read and characterizes the LLCE. Both programs produce a variety of reports, including a characterization report and a status report. The status report documents each action taken by the user, LLCEDATA, and LLCECALC. Documentation for LLCEDATA and LLCECALC for Windows is available in three volumes. Volume 1 is a user's manual, which is intended as a quick reference for both LLCEDATA and LLCECALC. Volume 2 is a technical manual, and Volume 3 is a software verification and validation document

  12. Validation gets underway on Sizewell ''Incredibility of Failure'' components

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The Inspection Validation Centre (IVC) of AEA Reactor Services in the UK has begun an eighteen month programme to validate the procedures and personnel of OIS plc, the inspection agents chosen by Nuclear Electric to carry out the pre-service ultrasonic inspection of the Sizewell B Pressurized Water Reactor components assigned to the ''Incredibility of Failure'' (IoF) category. The work involves several Sizewell B primary circuit components - the steam generators, pressurizer, and primary pumps - and will consider the inspections to be applied to the circumferential and nozzle-to-shell welds, nozzle inner radii and the pump fly-wheel forging. The validation will provide independent confirmation that OIS personnel are capable of using manual and automated methods to find and size any flaws of structural concern in these components. (author)

  13. Development of instructional manual encouraging student active learning for high school teaching on fluid mechanics through Torricelli's tank experiment

    Science.gov (United States)

    Apiwan, Suttinee; Puttharugsa, Chokchai; Khemmani, Supitch

    2018-01-01

    The purposes of this research were to help students to perform Physics laboratory by themselves and to provide guidelines for high school teacher to develop active learning on fluid mechanics by using Torricelli's tank experiment. The research was conducted as follows: 1) constructed an appropriate Torricelli's tank experiment for high school teaching and investigated the condition for maximum water falling distance. As a consequence, it was found that the distance of the falling water measured from the experiment was shorter than that obtained from the theory of ideal fluid because of the energy loss during a flow, 2) developed instructional manual for high school teaching that encourages active learning by using problem based learning (PBL) approach, which is consistent with the trend of teaching and learning in 21st century. The content validity of our instructional manual using Index of Item-objective Congruence (IOC) as evaluated by three experts was over 0.67. The manual developed was therefore qualified for classroom practice.

  14. A framework for the design of a voice-activated, intelligent, and hypermedia-based aircraft maintenance manual

    Science.gov (United States)

    Patankar, Manoj Shashikant

    estimates the United States air carriers to operate 3,991 large jet aircraft in the year 1996 (FAA Aviation Forecasts, 1987-1998). With an estimate of seventy manuals per such aircraft, the development of intelligent manuals is expected to impact 279,370 manuals in this country. Soon, over 55 thousand maintenance technicians will be able to carry the seven pound system to an aircraft, use voice commands to access the aircraft's files on the system, seek assistance from the expert system to diagnose the fault, and obtain instructions on how to rectify the fault. The evolutionary design approach and the rapid prototyping techniques were very well suited for the spiral testing strategy. Therefore, this strategy was used to test the structural and functional validity of this research. Professors Darrell Anderson and Brian Stout (Aviation faculty at San Jose State University) and Mr. Gregory Shea (a United Airlines mechanic and SJSU student) are representatives of the real-world users of the final product. Therefore, they conducted the alpha test of this prototype. Mr. Daniel Neal and Mr. Stephen Harms have been actively involved in light aircraft maintenance for more than ten years. They evaluated the prototype's usability. All the above evaluators used standard testing tools and evaluated the prototype under field conditions. The evaluators concluded that the VIHAMS prototype used a valid fault diagnosis strategy, the system architecture could be used to develop similar systems using off-the-shelf tools, and the voice input system could be refined to improve its usability.

  15. Development of an environmental safety case guidance manual

    International Nuclear Information System (INIS)

    Wellstead, Matthew John

    2014-01-01

    NDA RWMD is currently considering the scope, purpose and structure of a safety case manual that covers the development of nuclear operational, transport and environmental safety cases for a geological disposal facility in the United Kingdom. This paper considers the Environmental Safety Case (ESC) input into such a manual (herein referred to as the 'ESC Manual'), looking at the drivers and benefits that a guidance manual in this area may provide. (authors)

  16. Site security personnel training manual

    International Nuclear Information System (INIS)

    1978-10-01

    As required by 10 CFR Part 73, this training manual provides guidance to assist licensees in the development of security personnel training and qualifications programs. The information contained in the manual typifies the level and scope of training for personnel assigned to perform security related tasks and job duties associated with the protection of nuclear fuel cycle facilities and nuclear power reactors

  17. Music educators : their artistry and self-confidence

    NARCIS (Netherlands)

    Lion-Slovak, Brigitte; Stöger, Christine; Smilde, Rineke; Malmberg, Isolde; de Vugt, Adri

    2013-01-01

    How does artistic identity influence the self-confidence of music educators? What is the interconnection between the artistic and the teacher identity? What is actually meant by artistic identity in music education? What is a fruitful environment for the development of artistic self-confidence of

  18. Financial Literacy, Confidence and Financial Advice Seeking

    NARCIS (Netherlands)

    Kramer, Marc M.

    2016-01-01

    We find that people with higher confidence in their own financial literacy are less likely to seek financial advice, but no relation between objective measures of literacy and advice seeking. The negative association between confidence and advice seeking is more pronounced among wealthy households.

  19. Radiation protection manual

    International Nuclear Information System (INIS)

    Spang, A.

    1983-01-01

    According to the Radiation Protection Ordinance, radiation protection experts directing or supervising the handling of radioactive materials must have expert knowledge. The concept of expert knowledge has been clearly defined by the Fachverband e.V. in a catalogue of instruction goals. The manual follows the principles of this catalogue; it presents the expert knowledge required in a total of 15 subject groups. There is an index which helps the reader to find his specific subject group and the knowledge required of him in this subject group. However, the manual gives only an outline of the subject matter in many instances and should therefore not be regarded as a textbook in the proper sense. (orig./HP) [de

  20. Gravel Roads: Maintenance and Design Manual

    Science.gov (United States)

    This manual was developed with a major emphasis on the maintenance of gravel roads, including some basic design elements. The purpose of the manual is to provide clear and helpful information for doing a better job of maintaining gravel roads.

  1. Protein Correlation Profiles Identify Lipid Droplet Proteins with High Confidence*

    Science.gov (United States)

    Krahmer, Natalie; Hilger, Maximiliane; Kory, Nora; Wilfling, Florian; Stoehr, Gabriele; Mann, Matthias; Farese, Robert V.; Walther, Tobias C.

    2013-01-01

    Lipid droplets (LDs) are important organelles in energy metabolism and lipid storage. Their cores are composed of neutral lipids that form a hydrophobic phase and are surrounded by a phospholipid monolayer that harbors specific proteins. Most well-established LD proteins perform important functions, particularly in cellular lipid metabolism. Morphological studies show LDs in close proximity to and interacting with membrane-bound cellular organelles, including the endoplasmic reticulum, mitochondria, peroxisomes, and endosomes. Because of these close associations, it is difficult to purify LDs to homogeneity. Consequently, the confident identification of bona fide LD proteins via proteomics has been challenging. Here, we report a methodology for LD protein identification based on mass spectrometry and protein correlation profiles. Using LD purification and quantitative, high-resolution mass spectrometry, we identified LD proteins by correlating their purification profiles to those of known LD proteins. Application of the protein correlation profile strategy to LDs isolated from Drosophila S2 cells led to the identification of 111 LD proteins in a cellular LD fraction in which 1481 proteins were detected. LD localization was confirmed in a subset of identified proteins via microscopy of the expressed proteins, thereby validating the approach. Among the identified LD proteins were both well-characterized LD proteins and proteins not previously known to be localized to LDs. Our method provides a high-confidence LD proteome of Drosophila cells and a novel approach that can be applied to identify LD proteins of other cell types and tissues. PMID:23319140

  2. Confidence building in implementation of geological disposal

    International Nuclear Information System (INIS)

    Umeki, Hiroyuki

    2004-01-01

    Long-term safety of the disposal system should be demonstrated to the satisfaction of the stakeholders. Convincing arguments are therefore required that instil in the stakeholders confidence in the safety of a particular concept for the siting and design of a geological disposal, given the uncertainties that inevitably exist in its a priori description and in its evolution. The step-wise approach associated with making safety case at each stage is a key to building confidence in the repository development programme. This paper discusses aspects and issues on confidence building in the implementation of HLW disposal in Japan. (author)

  3. Radar and ARPA manual

    CERN Document Server

    Bole, A G

    2013-01-01

    Radar and ARPA Manual focuses on the theoretical and practical aspects of electronic navigation. The manual first discusses basic radar principles, including principles of range and bearing measurements and picture orientation and presentation. The text then looks at the operational principles of radar systems. Function of units; aerial, receiver, and display principles; transmitter principles; and sitting of units on board ships are discussed. The book also describes target detection, Automatic Radar Plotting Aids (ARPA), and operational controls of radar systems, and then discusses radar plo

  4. HASL procedures manual

    International Nuclear Information System (INIS)

    Harley, J.H.

    1977-08-01

    Additions and corrections to the following sections of the HASL Procedures Manual are provided: General, Sampling, Field Measurements; General Analytical Chemistry, Chemical Procedures, Data Section, and Specifications

  5. Design and validation of a CT-guided robotic system for lung cancer brachytherapy.

    Science.gov (United States)

    Dou, Huaisu; Jiang, Shan; Yang, Zhiyong; Sun, Luqing; Ma, Xiaodong; Huo, Bin

    2017-09-01

    Currently, lung brachytherapy in clinical setting is a complex procedure. Operation accuracy depends on accurate positioning of the template; however, it is difficult to guarantee the positioning accuracy manually. Application of robotic-assisted systems can simplify the procedure and improve the manual positioning accuracy. Therefore, a novel CT-guided robotic system was developed to assist the lung cancer brachytherapy. A four degree-of-freedom (DOF) robot, controlled by a lung brachytherapy treatment planning system (TPS) software, was designed and manufactured to assist the template positioning. Target position of the template can be obtained from the treatment plan, thus the robot is driven to the target position automatically. The robotic system was validated in both the laboratory and the CT environment. In laboratory environment, a 3D laser tracker and an inertial measurement unit (IMU) were used to measure the mechanical accuracy in air, which includes positioning accuracy and position repeatability. Working reliability was also validated in this procedure by observing the response reliability and calculating the position repeatability. Imaging artifacts and accuracy of the robot registration were validated in the CT environment by using an artificial phantom with fiducial markers. CT images were obtained and used to test the image artifact and calculate the registration accuracy. Phantom experiments were conducted to test the accuracy of needle insertion by using a transparent hydrogel phantom with a high imitation artificial phantom. Also, the efficiency was validated in this procedure by comparing time costs in manual positioning with robotic positioning under the same experimental conditions. The robotic system achieved the positioning accuracy of 0.28 ± 0.25 mm and the position repeatability of 0.09 ± 0.11 mm. Experimental results showed that the robot was CT-compatible and responded reliably to the control commands. The mean registration accuracy

  6. The identification and modeling of visual cue usage in manual control task experiments

    Science.gov (United States)

    Sweet, Barbara Townsend

    Many fields of endeavor require humans to conduct manual control tasks while viewing a perspective scene. Manual control refers to tasks in which continuous, or nearly continuous, control adjustments are required. Examples include flying an aircraft, driving a car, and riding a bicycle. Perspective scenes can arise through natural viewing of the world, simulation of a scene (as in flight simulators), or through imaging devices (such as the cameras on an unmanned aerospace vehicle). Designers frequently have some degree of control over the content and characteristics of a perspective scene; airport designers can choose runway markings, vehicle designers can influence the size and shape of windows, as well as the location of the pilot, and simulator database designers can choose scene complexity and content. Little theoretical framework exists to help designers determine the answers to questions related to perspective scene content. An empirical approach is most commonly used to determine optimum perspective scene configurations. The goal of the research effort described in this dissertation has been to provide a tool for modeling the characteristics of human operators conducting manual control tasks with perspective-scene viewing. This is done for the purpose of providing an algorithmic, as opposed to empirical, method for analyzing the effects of changing perspective scene content for closed-loop manual control tasks. The dissertation contains the development of a model of manual control using a perspective scene, called the Visual Cue Control (VCC) Model. Two forms of model were developed: one model presumed that the operator obtained both position and velocity information from one visual cue, and the other model presumed that the operator used one visual cue for position, and another for velocity. The models were compared and validated in two experiments. The results show that the two-cue VCC model accurately characterizes the output of the human operator with a

  7. The Bulimia Test--Revised: Validation with "DSM-IV" Criteria for Bulimia Nervosa.

    Science.gov (United States)

    Thelen, Mark H.; And Others

    1996-01-01

    The Bulimia Test--Revised (BULIT-R) was given to 23 female subjects who met the criteria for bulimia in the "Diagnostic and Statistical Manual of Mental Disorders" (DSM-IV) and 124 female controls. The BULIT-R appears to be a valid instruction for identifying individuals who meet DSM-IV criteria for bulimia. (SLD)

  8. Efficient utilization of energy in office buildings. Planning manual; Effiziente Energienutzung in Buerogebaeuden. Planungsleitfaden

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-15

    Regarding to the energy efficiency of office buildings, a high standard is set to architects: Office buildings need more energy for the cooling in the summer than for the heating in the winter. Additionally, there is an energy consumption for lighting, ventilation and operation of office equipment. Under this aspect, in the planning manual under consideration ten demands for an efficient energy utilization at office buildings are described: (a) Integral concept for the minimization of the entire power demand; (b) Compact building method and very good structural thermal protection; (c) Adapted glass areas and quality of vitrifications; (d) Integrals ventilation planning; (e) Efficient ventilation systems; (f) Efficient room climate concept and minimization of internal and outside heat loads; (g) Utilization of daylight with adapted architectural draft; (h) Efficient artificial lighting; (i) Supply of warmth and coldness with minimum characteristic values for primary energy; (j) Energy monitoring and optimization of operation. This manual also is valid for other buildings such as schools, administration buildings or swimming pools.

  9. Design, validation, and reliability of survey to measure female athlete triad knowledge among coaches

    Directory of Open Access Journals (Sweden)

    Jillian E. Frideres

    2015-06-01

    Full Text Available The purpose of this study was to design and to test the validity and reliability of an instrument to evaluate coaches' knowledge about the female athlete triad syndrome and their confidence in this knowledge. The instrument collects information regarding: knowledge of the syndrome, components, prevention and intervention; confidence of the coaches in their answers; and coach's characteristics (gender, degree held, years of experience in coaching females, continuing education participation specific to the syndrome and its components, and sport coached. The process of designing the questionnaire and testing the validity and reliability of it was done in four phases: a design and development of the instrument, b content validity, c instrument reliability, and d concurrent validity. The results show that the instrument is suitable for measuring coaches' female athlete triad knowledge. The instrument can contribute to assessing the coaches' knowledge level in relation to this topic.

  10. Frontline nurse managers' confidence and self-efficacy.

    Science.gov (United States)

    Van Dyk, Jennifer; Siedlecki, Sandra L; Fitzpatrick, Joyce J

    2016-05-01

    This study was focused on determining relationships between confidence levels and self-efficacy among nurse managers. Frontline nurse managers have a pivotal role in delivering high-quality patient care while managing the associated costs and resources. The competency and skill of nurse managers affect every aspect of patient care and staff well-being as nurse managers are largely responsible for creating work environments in which clinical nurses are able to provide high-quality, patient-centred, holistic care. A descriptive, correlational survey design was used; 85 nurse managers participated. Years in a formal leadership role and confidence scores were found to be significant predictors of self-efficacy scores. Experience as a nurse manager is an important component of confidence and self-efficacy. There is a need to develop educational programmes for nurse managers to enhance their self-confidence and self-efficacy, and to maintain experienced nurse managers in the role. © 2016 John Wiley & Sons Ltd.

  11. Weighting Mean and Variability during Confidence Judgments

    Science.gov (United States)

    de Gardelle, Vincent; Mamassian, Pascal

    2015-01-01

    Humans can not only perform some visual tasks with great precision, they can also judge how good they are in these tasks. However, it remains unclear how observers produce such metacognitive evaluations, and how these evaluations might be dissociated from the performance in the visual task. Here, we hypothesized that some stimulus variables could affect confidence judgments above and beyond their impact on performance. In a motion categorization task on moving dots, we manipulated the mean and the variance of the motion directions, to obtain a low-mean low-variance condition and a high-mean high-variance condition with matched performances. Critically, in terms of confidence, observers were not indifferent between these two conditions. Observers exhibited marked preferences, which were heterogeneous across individuals, but stable within each observer when assessed one week later. Thus, confidence and performance are dissociable and observers’ confidence judgments put different weights on the stimulus variables that limit performance. PMID:25793275

  12. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual radionuclide applicator system. 892.5650.... This generic type of device may include patient and equipment supports, component parts, treatment...

  13. Waste Management Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Buckingham, J.S. [ed.

    1967-08-31

    This Manual has been prepared to provide a documented compendium of the technical bases and general physical features of Isochem Incorporated`s Waste Management Program. The manual is intended to be used as a means of training and as a reference handbook for use by personnel responsible for executing the Waste Management Program. The material in this manual was assembled by members of Isochem`s Chemical Processing Division, Battelle Northwest Laboratory, and Hanford Engineering Services between September 1965 and March 1967. The manual is divided into the following parts: Introduction, contains a summary of the overall Waste Management Program. It is written to provide the reader with a synoptic view and as an aid in understanding the subsequent parts; Feed Material, contains detailed discussion of the type and sources of feed material used in the Waste Management Program, including a chapter on nuclear reactions and the formation of fission products; Waste Fractionization Plant Processing, contains detailed discussions of the processes used in the Waste Fractionization Plant with supporting data and documentation of the technology employed; Waste Fractionization Plant Product and Waste Effluent Handling, contains detailed discussions of the methods of handling the product and waste material generated by the Waste Fractionization Plant; Plant and Equipment, describes the layout of the Waste Management facilities, arrangement of equipment, and individual equipment pieces; Process Control, describes the instruments and analytical methods used for process control; and Safety describes process hazards and the methods used to safeguard against them.

  14. US Department of Energy radiological control manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    This manual establishes practices for the conduct of Department of Energy radiological control activities. The Manual states DOE`s positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. This Manual is not a substitute for Regulations; it is intended to be consistent with all relevant statutory and regulatory requirements and shall be revised whenever necessary to ensure such consistency. Some of the Manual provisions, however, challenge the user to go well beyond minimum requirements. Following the course of action delineated in the Manual will result in achieving and surpassing related statutory or regulatory requirements.

  15. Confidence and self-attribution bias in an artificial stock market

    Science.gov (United States)

    Bertella, Mario A.; Pires, Felipe R.; Rego, Henio H. A.; Vodenska, Irena; Stanley, H. Eugene

    2017-01-01

    Using an agent-based model we examine the dynamics of stock price fluctuations and their rates of return in an artificial financial market composed of fundamentalist and chartist agents with and without confidence. We find that chartist agents who are confident generate higher price and rate of return volatilities than those who are not. We also find that kurtosis and skewness are lower in our simulation study of agents who are not confident. We show that the stock price and confidence index—both generated by our model—are cointegrated and that stock price affects confidence index but confidence index does not affect stock price. We next compare the results of our model with the S&P 500 index and its respective stock market confidence index using cointegration and Granger tests. As in our model, we find that stock prices drive their respective confidence indices, but that the opposite relationship, i.e., the assumption that confidence indices drive stock prices, is not significant. PMID:28231255

  16. Procedure manual for the estimation of average indoor radon-daughter concentrations using the filtered alpha-track method

    International Nuclear Information System (INIS)

    George, J.L.

    1988-04-01

    One of the measurement needs of US Department of Energy (DOE) remedial action programs is the estimation of the annual-average indoor radon-daughter concentration (RDC) in structures. The filtered alpha-track method, using a 1-year exposure period, can be used to accomplish RDC estimations for the DOE remedial action programs. This manual describes the procedure used to obtain filtered alpha-track measurements to derive average RDC estimates from the measurrements. Appropriate quality-assurance and quality-control programs are also presented. The ''prompt'' alpha-track method of exposing monitors for 2 to 6 months during specific periods of the year is also briefly discussed in this manual. However, the prompt alpha-track method has been validated only for use in the Mesa County, Colorado, area. 3 refs., 3 figs

  17. Improved realism of confidence for an episodic memory event

    Directory of Open Access Journals (Sweden)

    Sandra Buratti

    2012-09-01

    Full Text Available We asked whether people can make their confidence judgments more realistic (accurate by adjusting them, with the aim of improving the relationship between the level of confidence and the correctness of the answer. This adjustment can be considered to include a so-called second-order metacognitive judgment. The participants first gave confidence judgments about their answers to questions about a video clip they had just watched. Next, they attempted to increase their accuracy by identifying confidence judgments in need of adjustment and then modifying them. The participants managed to increase their metacognitive realism, thus decreasing their absolute bias and improving their calibration, although the effects were small. We also examined the relationship between confidence judgments that were adjusted and the retrieval fluency and the phenomenological memory quality participants experienced when first answering the questions; this quality was one of either Remember (associated with concrete, vivid details or Know (associated with a feeling of familiarity. Confidence judgments associated with low retrieval fluency and the memory quality of knowing were modified more often. In brief, our results provide evidence that people can improve the realism of their confidence judgments, mainly by decreasing their confidence for incorrect answers. Thus, this study supports the conclusion that people can perform successful second-order metacognitive judgments.

  18. MANUAL LOGIC CONTROLLER (MLC)

    OpenAIRE

    Claude Ziad Bayeh

    2015-01-01

    The “Manual Logic Controller” also called MLC, is an electronic circuit invented and designed by the author in 2008, in order to replace the well known PLC (Programmable Logic Controller) in many applications for its advantages and its low cost of fabrication. The function of the MLC is somewhat similar to the well known PLC, but instead of doing it by inserting a written program into the PLC using a computer or specific software inside the PLC, it will be manually programmed in a manner to h...

  19. Security electronics circuits manual

    CERN Document Server

    MARSTON, R M

    1998-01-01

    Security Electronics Circuits Manual is an invaluable guide for engineers and technicians in the security industry. It will also prove to be a useful guide for students and experimenters, as well as providing experienced amateurs and DIY enthusiasts with numerous ideas to protect their homes, businesses and properties.As with all Ray Marston's Circuits Manuals, the style is easy-to-read and non-mathematical, with the emphasis firmly on practical applications, circuits and design ideas. The ICs and other devices used in the practical circuits are modestly priced and readily available ty

  20. Towards Automatic Capturing of Manual Data Processing Provenance

    NARCIS (Netherlands)

    Wombacher, Andreas; Huq, M.R.

    2011-01-01

    Often data processing is not implemented by a work ow system or an integration application but is performed manually by humans along the lines of a more or less specified procedure. Collecting provenance information during manual data processing can not be automated. Further, manual collection of

  1. Building Public Confidence in Nuclear Activities

    International Nuclear Information System (INIS)

    Isaacs, T

    2002-01-01

    Achieving public acceptance has become a central issue in discussions regarding the future of nuclear power and associated nuclear activities. Effective public communication and public participation are often put forward as the key building blocks in garnering public acceptance. A recent international workshop in Finland provided insights into other features that might also be important to building and sustaining public confidence in nuclear activities. The workshop was held in Finland in close cooperation with Finnish stakeholders. This was most appropriate because of the recent successes in achieving positive decisions at the municipal, governmental, and Parliamentary levels, allowing the Finnish high-level radioactive waste repository program to proceed, including the identification and approval of a proposed candidate repository site. Much of the workshop discussion appropriately focused on the roles of public participation and public communications in building public confidence. It was clear that well constructed and implemented programs of public involvement and communication and a sense of fairness were essential in building the extent of public confidence needed to allow the repository program in Finland to proceed. It was also clear that there were a number of other elements beyond public involvement that contributed substantially to the success in Finland to date. And, in fact, it appeared that these other factors were also necessary to achieving the Finnish public acceptance. In other words, successful public participation and communication were necessary but not sufficient. What else was important? Culture, politics, and history vary from country to country, providing differing contexts for establishing and maintaining public confidence. What works in one country will not necessarily be effective in another. Nonetheless, there appear to be certain elements that might be common to programs that are successful in sustaining public confidence and some of

  2. Building Public Confidence in Nuclear Activities

    International Nuclear Information System (INIS)

    Isaacs, T

    2002-01-01

    Achieving public acceptance has become a central issue in discussions regarding the future of nuclear power and associated nuclear activities. Effective public communication and public participation are often put forward as the key building blocks in garnering public acceptance. A recent international workshop in Finland provided insights into other features that might also be important to building and sustaining public confidence in nuclear activities. The workshop was held in Finland in close cooperation with Finnish stakeholders. This was most appropriate because of the recent successes in achieving positive decisions at the municipal, governmental, and Parliamentary levels, allowing the Finnish high-level radioactive waste repository program to proceed, including the identification and approval of a proposed candidate repository site Much of the workshop discussion appropriately focused on the roles of public participation and public communications in building public confidence. It was clear that well constructed and implemented programs of public involvement and communication and a sense of fairness were essential in building the extent of public confidence needed to allow the repository program in Finland to proceed. It was also clear that there were a number of other elements beyond public involvement that contributed substantially to the success in Finland to date. And, in fact, it appeared that these other factors were also necessary to achieving the Finnish public acceptance. In other words, successful public participation and communication were necessary but not sufficient. What else was important? Culture, politics, and history vary from country to country, providing differing contexts for establishing and maintaining public confidence. What works in one country will not necessarily be effective in another. Nonetheless, there appear to be certain elements that might be common to programs that are successful in sustaining public confidence, and some of

  3. Creating Web Sites The Missing Manual

    CERN Document Server

    MacDonald, Matthew

    2006-01-01

    Think you have to be a technical wizard to build a great web site? Think again. For anyone who wants to create an engaging web site--for either personal or business purposes--Creating Web Sites: The Missing Manual demystifies the process and provides tools, techniques, and expert guidance for developing a professional and reliable web presence. Like every Missing Manual, you can count on Creating Web Sites: The Missing Manual to be entertaining and insightful and complete with all the vital information, clear-headed advice, and detailed instructions you need to master the task at hand. Autho

  4. IOLMaster versus Manual Keratometry after Photorefractive Keratectomy

    Directory of Open Access Journals (Sweden)

    Hasan Razmju

    2011-01-01

    Full Text Available Purpose: To compare keratometric measurements using a Javal type manual keratometer with IOLMaster in eyes undergoing photorefractive keratectomy (PRK for myopia. Methods: In this comparative case series, we studied patients aged 21 to 27 years scheduled for myopic PRK. Keratometry was performed preoperatively and three months after the procedure using a Javal type manual keratometer and the IOLMaster. We compared postoperative measurements obtained by both instruments with the clinical history method (CHM. Results: Seventy eyes of 35 patients with mean age of 23.45±1.55 years were studied. Mean preoperative spherical equivalent was -4.53±1.3 D. Average preoperative IOLMaster and manual keratometric readings were 45.95±1.23 D and 46.32±1.18 D, respectively. Postoperatively, mean IOLMaster measurements was 38.03±0.68 D and that of manual keratometry was 43.15±1.1 D. Compared to CHM measurements, the 95% limits of agreement were ‑5.95 to -0.85 for the IOLMaster and -1.44 to 4.04 for manual keratometry. Conclusion: Keratometric measurements with the IOLMaster and a Javal type manual device are comparable after PRK; both are largely deviant from the CHM and can yield misleading results.

  5. Interpretation of Confidence Interval Facing the Conflict

    Science.gov (United States)

    Andrade, Luisa; Fernández, Felipe

    2016-01-01

    As literature has reported, it is usual that university students in statistics courses, and even statistics teachers, interpret the confidence level associated with a confidence interval as the probability that the parameter value will be between the lower and upper interval limits. To confront this misconception, class activities have been…

  6. Incidence rates of surgically treated rhegmatogenous retinal detachment among manual workers, non-manual workers and housewives in Tuscany, Italy

    OpenAIRE

    Curti, Stefania; Coggon, David; Baldasseroni, Alberto; Cooke, Robin M. T.; Fresina, Michela; Campos, Emilio C.; Semeraro, Francesco; Zanardi, Francesca; Farioli, Andrea; Violante, Francesco S.; Mattioli, Stefano

    2013-01-01

    Purpose Candidate risk factors for idiopathic rhegmatogenous retinal detachment (RRD) include heavy manual handling (requiring Valsalva’s maneuver). We assessed incidence rates of surgically treated idiopathic RRD among manual workers, non-manual workers and housewives resident in Tuscany, Italy. Methods We retrieved all hospital discharge records bearing a principal diagnosis corresponding to RRD coupled with retinal surgery for any resident of Tuscany during 1997–2009. After elimination of ...

  7. The Northern States Power Company welding manual advisor

    International Nuclear Information System (INIS)

    Lu, Yi; Wood, R.M.

    1993-01-01

    The Welding Manual Advisor (WMA) is an object oriented expert system designed to assist Northern States Power (NSP) personnel in implementing the company's Welding Manual. The expert system captures the knowledge of welding experts, addresses important issues in welding activities and automates the use of the Welding Manual. It is estimated that use of the WMA will save $81,000 over the next six years at NSP, because of the reduction of labor and errors in the use of the Welding Manual, and facilitation of training of NSP personnel. The important features of the WMA include the accuracy and consistency in determining welding procedure and requirements, update capability, user friendly interface, on-line help function, back-up capability, and well-documented manuals

  8. Missouri DECA: 2010-2011 Policy Manual

    Science.gov (United States)

    Missouri Department of Elementary and Secondary Education, 2011

    2011-01-01

    This paper presents the Missouri DECA Policy Manual. This manual contains the following sections: (1) DECA Board of Directors; (2) State Sales Projects; (3) State Officers; (4) Districts; (5) Competitive Events; (6) General Conference Information; (7) Fall Leadership & State Officer Election Conference; (8) Central Region Leadership…

  9. NDS EXFOR manual

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1985-08-01

    EXFOR is the agreed exchange format for the transmission of nuclear reaction data between national and international nuclear data centers for the benefit of nuclear data users in all countries. The IAEA Nuclear Data Section uses the EXFOR system not only for the center-to-center data exchange but also as its data storage and retrieval system. This NDS EXFOR MANUAL therefore contains the agreed EXFOR coding rules and format, supplemented by NDS internal compilation rules. The EXFOR system and the EXFOR nuclear data library with several million data records originate from the cooperation of an increasing number of data centers whose names and addresses can be found inside the Manual. Their contributions and cooperative efforts are gratefully acknowledged. (author)

  10. REBA experimenters' manual

    International Nuclear Information System (INIS)

    Schuch, R.L.

    1977-04-01

    The REBA is a high-energy, pulsed electron beam or bremsstrahlung x-ray generator whose operational purpose is to provide an energy source of short duration for conducting experiments, primarily to determine material responses to rapid surface and in-depth deposition of energy. The purpose of this manual is to serve as a basic source of information for prospective users of REBA. Included is a brief discussion of the design and operation of the facility as well as a summary of output characteristics for electron beam modes and environmental data for x-ray operation. The manual also contains a description of the REBA experimental facilities, including geometry of the test cell, instrumentation and data collection capabilities, and services and support available to experimenters

  11. NDS EXFOR manual

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1996-01-01

    EXFOR is the agreed exchange format for the transmission of nuclear reaction data between national and international nuclear data centers for the benefit of nuclear data users in all countries. The IAEA Nuclear Data Section uses the EXFOR system not only for the center-to-center data exchange but also as its data storage and retrieval system. This NDS EXFOR MANUAL therefore contains the agreed EXFOR coding rules and format, supplemented by NDS internal compilation rules. The EXFOR system and the EXFOR nuclear data library with several million data records originate from the cooperation of an increasing number of data centers whose names and addresses can be found inside the Manual. Their contributions and cooperative efforts are gratefully acknowledged. (author)

  12. Is consumer confidence an indicator of JSE performance?

    OpenAIRE

    Kamini Solanki; Yudhvir Seetharam

    2014-01-01

    While most studies examine the impact of business confidence on market performance, we instead focus on the consumer because consumer spending habits are a natural extension of trading activity on the equity market. This particular study examines investor sentiment as measured by the Consumer Confidence Index in South Africa and its effect on the Johannesburg Stock Exchange (JSE). We employ Granger causality tests to investigate the relationship across time between the Consumer Confidence Ind...

  13. Confidence Interval Approximation For Treatment Variance In ...

    African Journals Online (AJOL)

    In a random effects model with a single factor, variation is partitioned into two as residual error variance and treatment variance. While a confidence interval can be imposed on the residual error variance, it is not possible to construct an exact confidence interval for the treatment variance. This is because the treatment ...

  14. 21 CFR 866.2180 - Manual colony counter.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter. (a) Identification. A manual colony counter is a device intended for medical purposes that consists...

  15. Self-confidence of anglers in identification of freshwater sport fish

    Science.gov (United States)

    Chizinski, C.J.; Martin, D. R.; Pope, Kevin L.

    2014-01-01

    Although several studies have focused on how well anglers identify species using replicas and pictures, there has been no study assessing the confidence that can be placed in angler's ability to identify recreationally important fish. Understanding factors associated with low self-confidence will be useful in tailoring education programmes to improve self-confidence in identifying common species. The purposes of this assessment were to quantify the confidence of recreational anglers to identify 13 commonly encountered warm water fish species and to relate self-confidence to species availability and angler experience. Significant variation was observed in anglers self-confidence among species and levels of self-declared skill, with greater confidence associated with greater skill and with greater exposure. This study of angler self-confidence strongly highlights the need for educational programmes that target lower skilled anglers and the importance of teaching all anglers about less common species, regardless of skill level.

  16. Effects of postidentification feedback on eyewitness identification and nonidentification confidence.

    Science.gov (United States)

    Semmler, Carolyn; Brewer, Neil; Wells, Gary L

    2004-04-01

    Two experiments investigated new dimensions of the effect of confirming feedback on eyewitness identification confidence using target-absent and target-present lineups and (previously unused) unbiased witness instructions (i.e., "offender not present" option highlighted). In Experiment 1, participants viewed a crime video and were later asked to try to identify the thief from an 8-person target-absent photo array. Feedback inflated witness confidence for both mistaken identifications and correct lineup rejections. With target-present lineups in Experiment 2, feedback inflated confidence for correct and mistaken identifications and lineup rejections. Although feedback had no influence on the confidence-accuracy correlation, it produced clear overconfidence. Confidence inflation varied with the confidence measure reference point (i.e., retrospective vs. current confidence) and identification response latency.

  17. Evaluation of bone formation in calcium phosphate scaffolds with μCT-method validation using SEM.

    Science.gov (United States)

    Lewin, S; Barba, A; Persson, C; Franch, J; Ginebra, M-P; Öhman-Mägi, C

    2017-10-05

    There is a plethora of calcium phosphate (CaP) scaffolds used as synthetic substitutes to bone grafts. The scaffold performance is often evaluated from the quantity of bone formed within or in direct contact with the scaffold. Micro-computed tomography (μCT) allows three-dimensional evaluation of bone formation inside scaffolds. However, the almost identical x-ray attenuation of CaP and bone obtrude the separation of these phases in μCT images. Commonly, segmentation of bone in μCT images is based on gray scale intensity, with manually determined global thresholds. However, image analysis methods, and methods for manual thresholding in particular, lack standardization and may consequently suffer from subjectivity. The aim of the present study was to provide a methodological framework for addressing these issues. Bone formation in two types of CaP scaffold architectures (foamed and robocast), obtained from a larger animal study (a 12 week canine animal model) was evaluated by μCT. In addition, cross-sectional scanning electron microscopy (SEM) images were acquired as references to determine thresholds and to validate the result. μCT datasets were registered to the corresponding SEM reference. Global thresholds were then determined by quantitatively correlating the different area fractions in the μCT image, towards the area fractions in the corresponding SEM image. For comparison, area fractions were also quantified using global thresholds determined manually by two different approaches. In the validation the manually determined thresholds resulted in large average errors in area fraction (up to 17%), whereas for the evaluation using SEM references, the errors were estimated to be less than 3%. Furthermore, it was found that basing the thresholds on one single SEM reference gave lower errors than determining them manually. This study provides an objective, robust and less error prone method to determine global thresholds for the evaluation of bone formation in

  18. State Energy Program Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Office of Building Technology, State and Community Programs

    1999-03-17

    The State Energy Program Operations Manual is a reference tool for the states and the program officials at the U.S. Department of Energy's Office of Building Technology, State and Community Programs and Regional Support Offices as well as State Energy Offices. The Manual contains information needed to apply for and administer the State Energy Program, including program history, application rules and requirements, and program administration and monitoring requirements.

  19. Confidence Intervals from Normalized Data: A correction to Cousineau (2005

    Directory of Open Access Journals (Sweden)

    Richard D. Morey

    2008-09-01

    Full Text Available Presenting confidence intervals around means is a common method of expressing uncertainty in data. Loftus and Masson (1994 describe confidence intervals for means in within-subjects designs. These confidence intervals are based on the ANOVA mean squared error. Cousineau (2005 presents an alternative to the Loftus and Masson method, but his method produces confidence intervals that are smaller than those of Loftus and Masson. I show why this is the case and offer a simple correction that makes the expected size of Cousineau confidence intervals the same as that of Loftus and Masson confidence intervals.

  20. Manual for a Volunteer Services System.

    Science.gov (United States)

    Helgerson, Linda; And Others

    This manual presents guidelines for planning, monitoring, and controlling the development and operation of volunteer assistance programs. The materials included address questions related to both the process of establishing a volunteer program and the administration of a volunteer management system. The manual is not intended to provide a blueprint…

  1. Host Families Matter: The Homestay Manual.

    Science.gov (United States)

    Peace Corps, Washington, DC. Information Collection and Exchange Div.

    This manual provides guidelines, sample documents, and sample lesson plans for the trainers, trainees, and host families involved in homestays for Peace Corps volunteers. The manual contains 11 sections that deal with the following topics: (1) introduction; (2) policy, timelines, and responsibilities; (3) medical and financial issues; (4) host…

  2. 21 CFR 886.1770 - Manual refractor.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1770 Manual refractor. (a) Identification. A manual refractor is a device that is a set of lenses of varous dioptric powers intended to measure the refractive error of the eye. (b) Classification. Class I (general controls). The device is exempt from the...

  3. Doubly Bayesian Analysis of Confidence in Perceptual Decision-Making.

    Science.gov (United States)

    Aitchison, Laurence; Bang, Dan; Bahrami, Bahador; Latham, Peter E

    2015-10-01

    Humans stand out from other animals in that they are able to explicitly report on the reliability of their internal operations. This ability, which is known as metacognition, is typically studied by asking people to report their confidence in the correctness of some decision. However, the computations underlying confidence reports remain unclear. In this paper, we present a fully Bayesian method for directly comparing models of confidence. Using a visual two-interval forced-choice task, we tested whether confidence reports reflect heuristic computations (e.g. the magnitude of sensory data) or Bayes optimal ones (i.e. how likely a decision is to be correct given the sensory data). In a standard design in which subjects were first asked to make a decision, and only then gave their confidence, subjects were mostly Bayes optimal. In contrast, in a less-commonly used design in which subjects indicated their confidence and decision simultaneously, they were roughly equally likely to use the Bayes optimal strategy or to use a heuristic but suboptimal strategy. Our results suggest that, while people's confidence reports can reflect Bayes optimal computations, even a small unusual twist or additional element of complexity can prevent optimality.

  4. Registered nurse leadership style and confidence in delegation.

    Science.gov (United States)

    Saccomano, Scott J; Pinto-Zipp, Genevieve

    2011-05-01

      Leadership and confidence in delegation are two important explanatory constructs of nursing practice. The relationship between these constructs, however, is not clearly understood. To be successful in their roles as leaders, regardless of their experience, registered nurses (RNs) need to understand how to best delegate. The present study explored and described the relationship between RN leadership styles, demographic variables and confidence in delegation in a community teaching hospital. Utilizing a cross-sectional survey design, RNs employed in one acute care hospital completed questionnaires that measured leadership style [Path-Goal Leadership Questionnaire (PGLQ)] and confidence in delegating patient care tasks [Confidence and Intent to Delegate Scale (CIDS)]. Contrary to expectations, the data did not confirm a relationship between confidence in delegating tasks to unlicensed assistive personnel (UAPs) and leadership style. Nurses who were diploma or associate degree prepared were initially less confident in delegating tasks to UAPs as compared with RNs holding a bachelor's degree or higher. Further, after 5 years of clinical nursing experience, nurses with less educational experience reported more confidence in delegating tasks as compared with RNs with more educational experience. The lack of a relationship between leadership style and confidence in delegating patient care tasks were discussed in terms of the PGLQ classification criteria and hospital unit differences. As suggested by the significant two-way interaction between educational preparation and clinical nursing experience, changes in the nurse's confidence in delegating patient care tasks to UAPs was a dynamic changing variable that resulted from the interplay between amount of educational preparation and years of clinical nursing experience in this population of nurses. Clearly, generalizability of these findings to nurses outside the US is questionable, thus nurse managers must be familiar

  5. 21 CFR 890.5180 - Manual patient rotation bed.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5180 Manual patient rotation bed. (a) Identification. A manual patient rotation bed is a device that turns a patient who is... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual patient rotation bed. 890.5180 Section 890...

  6. TV Trouble-Shooting Manual. Volumes 7-8. Part 3: Synchronisation and Deflection Circuits. Student and Instructor's Manuals.

    Science.gov (United States)

    Mukai, Masaaki; Kobayashi, Ryozo

    These volumes are, respectively, the self-instructional student manual and the teacher manual that cover the third set of training topics in this course for television repair technicians. Both contain identical information on synchronization and deflection circuits, including sections on the principle of synchronized deflection, synchronization…

  7. Electronic Versus Manual Data Processing: Evaluating the Use of Electronic Health Records in Out-of-Hospital Clinical Research

    Science.gov (United States)

    Newgard, Craig D.; Zive, Dana; Jui, Jonathan; Weathers, Cody; Daya, Mohamud

    2011-01-01

    Objectives To compare case ascertainment, agreement, validity, and missing values for clinical research data obtained, processed, and linked electronically from electronic health records (EHR), compared to “manual” data processing and record abstraction in a cohort of out-ofhospital trauma patients. Methods This was a secondary analysis of two sets of data collected for a prospective, population-based, out-of-hospital trauma cohort evaluated by 10 emergency medical services (EMS) agencies transporting to 16 hospitals, from January 1, 2006 through October 2, 2007. Eighteen clinical, operational, procedural, and outcome variables were collected and processed separately and independently using two parallel data processing strategies, by personnel blinded to patients in the other group. The electronic approach included electronic health record data exports from EMS agencies, reformatting and probabilistic linkage to outcomes from local trauma registries and state discharge databases. The manual data processing approach included chart matching, data abstraction, and data entry by a trained abstractor. Descriptive statistics, measures of agreement, and validity were used to compare the two approaches to data processing. Results During the 21-month period, 418 patients underwent both data processing methods and formed the primary cohort. Agreement was good to excellent (kappa 0.76 to 0.97; intraclass correlation coefficient 0.49 to 0.97), with exact agreement in 67% to 99% of cases, and a median difference of zero for all continuous and ordinal variables. The proportions of missing out-of-hospital values were similar between the two approaches, although electronic processing generated more missing outcomes (87 out of 418, 21%, 95% CI = 17% to 25%) than the manual approach (11 out of 418, 3%, 95% CI = 1% to 5%). Case ascertainment of eligible injured patients was greater using electronic methods (n = 3,008) compared to manual methods (n = 629). Conclusions In this

  8. Unraveling the Mechanisms of Manual Therapy: Modeling an Approach.

    Science.gov (United States)

    Bialosky, Joel E; Beneciuk, Jason M; Bishop, Mark D; Coronado, Rogelio A; Penza, Charles W; Simon, Corey B; George, Steven Z

    2018-01-01

    Synopsis Manual therapy interventions are popular among individual health care providers and their patients; however, systematic reviews do not strongly support their effectiveness. Small treatment effect sizes of manual therapy interventions may result from a "one-size-fits-all" approach to treatment. Mechanistic-based treatment approaches to manual therapy offer an intriguing alternative for identifying patients likely to respond to manual therapy. However, the current lack of knowledge of the mechanisms through which manual therapy interventions inhibit pain limits such an approach. The nature of manual therapy interventions further confounds such an approach, as the related mechanisms are likely a complex interaction of factors related to the patient, the provider, and the environment in which the intervention occurs. Therefore, a model to guide both study design and the interpretation of findings is necessary. We have previously proposed a model suggesting that the mechanical force from a manual therapy intervention results in systemic neurophysiological responses leading to pain inhibition. In this clinical commentary, we provide a narrative appraisal of the model and recommendations to advance the study of manual therapy mechanisms. J Orthop Sports Phys Ther 2018;48(1):8-18. doi:10.2519/jospt.2018.7476.

  9. Detecting Disease in Radiographs with Intuitive Confidence

    Directory of Open Access Journals (Sweden)

    Stefan Jaeger

    2015-01-01

    Full Text Available This paper argues in favor of a specific type of confidence for use in computer-aided diagnosis and disease classification, namely, sine/cosine values of angles represented by points on the unit circle. The paper shows how this confidence is motivated by Chinese medicine and how sine/cosine values are directly related with the two forces Yin and Yang. The angle for which sine and cosine are equal (45° represents the state of equilibrium between Yin and Yang, which is a state of nonduality that indicates neither normality nor abnormality in terms of disease classification. The paper claims that the proposed confidence is intuitive and can be readily understood by physicians. The paper underpins this thesis with theoretical results in neural signal processing, stating that a sine/cosine relationship between the actual input signal and the perceived (learned input is key to neural learning processes. As a practical example, the paper shows how to use the proposed confidence values to highlight manifestations of tuberculosis in frontal chest X-rays.

  10. LLCEDATA and LLCECALC for Windows version 1.0, Volume 1: User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    McFadden, J.G.

    1998-09-04

    LLCEDATA and LLCECALC for Windows are user-friendly computer software programs that work together to determine the proper waste designation, handling, and disposition requirements for Long Length Contaminated Equipment (LLCE). LLCEDATA reads from a variety of data bases to produce an equipment data file (EDF) that represents a snapshot of both the LLCE and the tank it originates from. LLCECALC reads the EDF and a gamma assay (AV2) file that is produced by the Flexible Receiver Gamma Energy Analysis System. LLCECALC performs corrections to the AV2 file as it is being read and characterizes the LLCE. Both programs produce a variety of reports, including a characterization report and a status report. The status report documents each action taken by the user, LLCEDATA, and LLCECALC. Documentation for LLCEDATA and LLCECALC for Windows is available in three volumes. Volume 1 is a user`s manual, which is intended as a quick reference for both LLCEDATA and LLCECALC. Volume 2 is a technical manual, and Volume 3 is a software verification and validation document.

  11. AKURASI HITUNG JUMLAH ERITROSIT METODE MANUAL DAN METODE OTOMATIS

    Directory of Open Access Journals (Sweden)

    Neni Oktiyani

    2017-12-01

    Full Text Available Hitung jumlah eritrosit dilakukan dengan menggunakan metode manual dan metode otomatis. Metode manual menggunakan alat Hemositometer dapat memberikan hasil yang dipercaya dan akurat tergantung keahlian dari teknisi laboratorium. Metode otomatis memberikan hasil yang lebih mudah, cepat dan teliti dibandingkan dengan cara manual. Tujuan penelitian untuk membandingkan akurasi hitung jumlah eritrosit metode manual dan metode otomatis. Jenis penelitian yang digunakan adalah survey analitik dengan rancangan cross sectional. Penelitian ini membandingkan data hasil hitung jumlah eritrosit antara metode manual dengan metode otomatis dengan menggunakan 3 jenis darah kontrol hitung jumlah eritrosit high, normal, dan low dengan 9 kali pengulangan. Hasil penelitian menunjukkan nilai rerata hitung jumlah eritrosit darah kontrol high metode manual sebesar 7,08 juta/µl dengan nilai bias 1,4% dan metode otomatis sebesar 7,03 juta/µl dengan nilai bias 0,7%. Rerata hitung jumlah eritrosit darah kontrol normal metode manual sebesar 4,50 juta/µl dengan nilai bias 0,9% dan metode otomatis sebesar 4,43 juta/µl dengan nilai bias 2,4%. Rerata hitung jumlah eritrosit darah kontrol low metode manual sebesar 1,72 juta/µl dengan nilai bias 4,4% dan metode otomatis sebesar 1,67 juta/µl dengan nilai bias 1,2%. Uji statistik menunjukkan tidak ada perbedaan akurasi yang bermakna antara hitung jumlah eritrosit metode manual dengan metode otomatis.

  12. High confidence in falsely recognizing prototypical faces.

    Science.gov (United States)

    Sampaio, Cristina; Reinke, Victoria; Mathews, Jeffrey; Swart, Alexandra; Wallinger, Stephen

    2018-06-01

    We applied a metacognitive approach to investigate confidence in recognition of prototypical faces. Participants were presented with sets of faces constructed digitally as deviations from prototype/base faces. Participants were then tested with a simple recognition task (Experiment 1) or a multiple-choice task (Experiment 2) for old and new items plus new prototypes, and they showed a high rate of confident false alarms to the prototypes. Confidence and accuracy relationship in this face recognition paradigm was found to be positive for standard items but negative for the prototypes; thus, it was contingent on the nature of the items used. The data have implications for lineups that employ match-to-suspect strategies.

  13. Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

    Science.gov (United States)

    Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L

    2017-08-07

    To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.

  14. Confidence mediates the sex difference in mental rotation performance.

    Science.gov (United States)

    Estes, Zachary; Felker, Sydney

    2012-06-01

    On tasks that require the mental rotation of 3-dimensional figures, males typically exhibit higher accuracy than females. Using the most common measure of mental rotation (i.e., the Mental Rotations Test), we investigated whether individual variability in confidence mediates this sex difference in mental rotation performance. In each of four experiments, the sex difference was reliably elicited and eliminated by controlling or manipulating participants' confidence. Specifically, confidence predicted performance within and between sexes (Experiment 1), rendering confidence irrelevant to the task reliably eliminated the sex difference in performance (Experiments 2 and 3), and manipulating confidence significantly affected performance (Experiment 4). Thus, confidence mediates the sex difference in mental rotation performance and hence the sex difference appears to be a difference of performance rather than ability. Results are discussed in relation to other potential mediators and mechanisms, such as gender roles, sex stereotypes, spatial experience, rotation strategies, working memory, and spatial attention.

  15. Sodium safety manual

    International Nuclear Information System (INIS)

    Hayes, D.J.; Gardiner, R.L.

    1980-09-01

    The sodium safety manual is based upon more than a decade of experience with liquid sodium at Berkeley Nuclear Laboratories (BNL). It draws particularly from the expertise and experience developed in the course of research work into sodium fires and sodium water reactions. It draws also on information obtained from the UKAEA and other sodium users. Many of the broad principles will apply to other Establishments but much of the detail is specific to BNL and as a consequence its application at other sites may well be limited. Accidents with sodium are at best unpleasant and at worst lethal in an extremely painful way. The object of this manual is to help prevent sodium accidents. It is not intended to give detailed advice on specific precautions for particular situations, but rather to set out the overall strategy which will ensure that sodium activities will be pursued safely. More detail is generally conveyed to staff by the use of local instructions known as Sodium Working Procedures (SWP's) which are not reproduced in this manual although a list of current SWP's is included. Much attention is properly given to the safe design and operation of larger facilities; nevertheless evidence suggests that sodium accidents most frequently occur in small-scale work particularly in operations associated with sodium cleaning and special care is needed in all such cases. (U.K.)

  16. Equipment Qualification Data Base user manual

    International Nuclear Information System (INIS)

    Decker, Q.R.; Fackrell, L.J.; Fitch, L.R.; Meeky, O.B.

    1985-09-01

    This manual details the Equipment Qualification Data Base (EQDB), its usage, and contents. The EQDB consists of two files; the Plant Qualification File (PQF) and the Equipment Qualification File (EQF). The PQF contains plant specific environmental data and the EQF contains summaries of various test results. Two data management systems are used to manipulate the data and are discussed in this manual. SAS Institute System 2000 (S2K) is the management system for the PQF and Query Update (QU) is the operating system for the EQF. Each management system contains report writers. These writers and how to use them are discussed in detail in this manual

  17. AutoBayes Program Synthesis System Users Manual

    Science.gov (United States)

    Schumann, Johann; Jafari, Hamed; Pressburger, Tom; Denney, Ewen; Buntine, Wray; Fischer, Bernd

    2008-01-01

    Program synthesis is the systematic, automatic construction of efficient executable code from high-level declarative specifications. AutoBayes is a fully automatic program synthesis system for the statistical data analysis domain; in particular, it solves parameter estimation problems. It has seen many successful applications at NASA and is currently being used, for example, to analyze simulation results for Orion. The input to AutoBayes is a concise description of a data analysis problem composed of a parameterized statistical model and a goal that is a probability term involving parameters and input data. The output is optimized and fully documented C/C++ code computing the values for those parameters that maximize the probability term. AutoBayes can solve many subproblems symbolically rather than having to rely on numeric approximation algorithms, thus yielding effective, efficient, and compact code. Statistical analysis is faster and more reliable, because effort can be focused on model development and validation rather than manual development of solution algorithms and code.

  18. Aging and Confidence Judgments in Item Recognition

    Science.gov (United States)

    Voskuilen, Chelsea; Ratcliff, Roger; McKoon, Gail

    2018-01-01

    We examined the effects of aging on performance in an item-recognition experiment with confidence judgments. A model for confidence judgments and response time (RTs; Ratcliff & Starns, 2013) was used to fit a large amount of data from a new sample of older adults and a previously reported sample of younger adults. This model of confidence…

  19. Laboratory Waste Disposal Manual. Revised Edition.

    Science.gov (United States)

    Stephenson, F. G., Ed.

    This manual is designed to provide laboratory personnel with information about chemical hazards and ways of disposing of chemical wastes with minimum contamination of the environment. The manual contains a reference chart section which has alphabetical listings of some 1200 chemical substances with information on the health, fire and reactivity…

  20. Manual for Training Leprosy Rehabilitation Workers.

    Science.gov (United States)

    Itoh, Masayoshi; Eason, Alice L.

    The purpose of this manual is to introduce the general concepts and techniques in leprosy rehabilitation to physical therapy aides. Because of the lack of well-trained, qualified, physical therapists, the committee on leprosy rehabilitation considers it necessary to publish a teaching manual outlining leprosy rehabilitation for those who work with…

  1. Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes

    Directory of Open Access Journals (Sweden)

    Dariusz Wroblewski

    2014-01-01

    Full Text Available Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1 manual, with patient response registered with a mouse click, and (2 visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1 minimal systematic differences between measurements taken in visual grasp and manual modes, (2 the average standard deviation of the difference distributions of about 5 dB, and (3 a systematic shift (of 4–6 dB to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients’ acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  2. Testing of visual field with virtual reality goggles in manual and visual grasp modes.

    Science.gov (United States)

    Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  3. User Manual for the NASA Glenn Ice Accretion Code LEWICE. Version 2.2.2

    Science.gov (United States)

    Wright, William B.

    2002-01-01

    A research project is underway at NASA Glenn to produce a computer code which can accurately predict ice growth under a wide range of meteorological conditions for any aircraft surface. This report will present a description of the code inputs and outputs from version 2.2.2 of this code, which is called LEWICE. This version differs from release 2.0 due to the addition of advanced thermal analysis capabilities for de-icing and anti-icing applications using electrothermal heaters or bleed air applications. An extensive effort was also undertaken to compare the results against the database of electrothermal results which have been generated in the NASA Glenn Icing Research Tunnel (IRT) as was performed for the validation effort for version 2.0. This report will primarily describe the features of the software related to the use of the program. Appendix A of this report has been included to list some of the inner workings of the software or the physical models used. This information is also available in the form of several unpublished documents internal to NASA. This report is intended as a replacement for all previous user manuals of LEWICE. In addition to describing the changes and improvements made for this version, information from previous manuals may be duplicated so that the user will not need to consult previous manuals to use this code.

  4. Beyond the Manual Channel

    DEFF Research Database (Denmark)

    , the main focus there is on spoken languages in their written and spoken forms. This series of workshops, however, offers a forum for researchers focussing on sign languages. For the fourth time, the workshop had sign language corpora as its main topic. This time, the focus was on any aspect beyond...... the manual channel. Not surprisingly, most papers deal with non-manuals on the face. Once again, the papers at this workshop clearly identify the potentials of even closer cooperation between sign linguists and sign language engineers, and we think it is events like this that contribute a lot to a better...

  5. RELAP-7 Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Berry, Ray Alden [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Peterson, John William [Idaho National Lab. (INL), Idaho Falls, ID (United States); Martineau, Richard Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kadioglu, Samet Yucel [Idaho National Lab. (INL), Idaho Falls, ID (United States); Andrs, David [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    This document summarizes the physical models and mathematical formulations used in the RELAP-7 code. In summary, the MOOSE based RELAP-7 code development is an ongoing effort. The MOOSE framework enables rapid development of the RELAP-7 code. The developmental efforts and results demonstrate that the RELAP-7 project is on a path to success. This theory manual documents the main features implemented into the RELAP-7 code. Because the code is an ongoing development effort, this RELAP-7 Theory Manual will evolve with periodic updates to keep it current with the state of the development, implementation, and model additions/revisions.

  6. Data collection system. Volume 1, Overview and operators manual; Volume 2, Maintenance manual; Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, R.B.; Bauder, M.E.; Boyer, W.B.; French, R.E.; Isidoro, R.J.; Kaestner, P.C.; Perkins, W.G.

    1993-09-01

    Sandia National Laboratories (SNL) Instrumentation Development Department was tasked by the Defense Nuclear Agency (DNA) to record data on Tektronix RTD720 Digitizers on the HUNTERS TROPHY field test conducted at the Nevada Test Site (NTS) on September 18, 1992. This report contains a overview and description of the computer hardware and software that was used to acquire, reduce, and display the data. The document is divided into two volumes: an overview and operators manual (Volume 1) and a maintenance manual (Volume 2).

  7. Quality assurance manual for the development of digital systems

    International Nuclear Information System (INIS)

    Lee, Cheol Kwon; Kwon, Kee Choon; You, Young Eun; Kim, Kwan Hyun; Park, Jung Woo; Park, Chan Seok

    2001-12-01

    A digital safety system is being developed by three companies under the Korea Nuclear I and C System R and D Program. This Quality Assurance Manual (QAM) is written to ensure the safety and reliability of the system and to meet the regulatory requirements associated with quality assurance. This QAM describes eighteen elements of quality assurance criteria required for the development of the system, which are coincident with the criteria specified in Nuclear Energy Laws and Enforcement Regulations of Nuclear Energy Laws and 10CFR50 Appendix B. This QAM is submitted to the regulatory body with other documents related to the quality assurance activities performed during the system development. And its safety, validity and fulfillment are reviewed and audited in the review process of topical report of the digital safety system

  8. TASS code topical report. V.1 TASS code technical manual

    International Nuclear Information System (INIS)

    Sim, Suk K.; Chang, W. P.; Kim, K. D.; Kim, H. C.; Yoon, H. Y.

    1997-02-01

    TASS 1.0 code has been developed at KAERI for the initial and reload non-LOCA safety analysis for the operating PWRs as well as the PWRs under construction in Korea. TASS code will replace various vendor's non-LOCA safety analysis codes currently used for the Westinghouse and ABB-CE type PWRs in Korea. This can be achieved through TASS code input modifications specific to each reactor type. The TASS code can be run interactively through the keyboard operation. A simimodular configuration used in developing the TASS code enables the user easily implement new models. TASS code has been programmed using FORTRAN77 which makes it easy to install and port for different computer environments. The TASS code can be utilized for the steady state simulation as well as the non-LOCA transient simulations such as power excursions, reactor coolant pump trips, load rejections, loss of feedwater, steam line breaks, steam generator tube ruptures, rod withdrawal and drop, and anticipated transients without scram (ATWS). The malfunctions of the control systems, components, operator actions and the transients caused by the malfunctions can be easily simulated using the TASS code. This technical report describes the TASS 1.0 code models including reactor thermal hydraulic, reactor core and control models. This TASS code models including reactor thermal hydraulic, reactor core and control models. This TASS code technical manual has been prepared as a part of the TASS code manual which includes TASS code user's manual and TASS code validation report, and will be submitted to the regulatory body as a TASS code topical report for a licensing non-LOCA safety analysis for the Westinghouse and ABB-CE type PWRs operating and under construction in Korea. (author). 42 refs., 29 tabs., 32 figs

  9. Maximum-confidence discrimination among symmetric qudit states

    International Nuclear Information System (INIS)

    Jimenez, O.; Solis-Prosser, M. A.; Delgado, A.; Neves, L.

    2011-01-01

    We study the maximum-confidence (MC) measurement strategy for discriminating among nonorthogonal symmetric qudit states. Restricting to linearly dependent and equally likely pure states, we find the optimal positive operator valued measure (POVM) that maximizes our confidence in identifying each state in the set and minimizes the probability of obtaining inconclusive results. The physical realization of this POVM is completely determined and it is shown that after an inconclusive outcome, the input states may be mapped into a new set of equiprobable symmetric states, restricted, however, to a subspace of the original qudit Hilbert space. By applying the MC measurement again onto this new set, we can still gain some information about the input states, although with less confidence than before. This leads us to introduce the concept of sequential maximum-confidence (SMC) measurements, where the optimized MC strategy is iterated in as many stages as allowed by the input set, until no further information can be extracted from an inconclusive result. Within each stage of this measurement our confidence in identifying the input states is the highest possible, although it decreases from one stage to the next. In addition, the more stages we accomplish within the maximum allowed, the higher will be the probability of correct identification. We will discuss an explicit example of the optimal SMC measurement applied in the discrimination among four symmetric qutrit states and propose an optical network to implement it.

  10. Validation of a novel automatic sleep spindle detector with high performance during sleep in middle aged subjects

    DEFF Research Database (Denmark)

    Wendt, Sabrina Lyngbye; Christensen, Julie A. E.; Kempfner, Jacob

    2012-01-01

    Many of the automatic sleep spindle detectors currently used to analyze sleep EEG are either validated on young subjects or not validated thoroughly. The purpose of this study is to develop and validate a fast and reliable sleep spindle detector with high performance in middle aged subjects....... An automatic sleep spindle detector using a bandpass filtering approach and a time varying threshold was developed. The validation was done on sleep epochs from EEG recordings with manually scored sleep spindles from 13 healthy subjects with a mean age of 57.9 ± 9.7 years. The sleep spindle detector reached...

  11. Understanding public confidence in government to prevent terrorist attacks.

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, T. E.; Ramaprasad, A,; Samsa, M. E.; Decision and Information Sciences; Univ. of Illinois at Chicago

    2008-04-02

    A primary goal of terrorism is to instill a sense of fear and vulnerability in a population and to erode its confidence in government and law enforcement agencies to protect citizens against future attacks. In recognition of its importance, the Department of Homeland Security includes public confidence as one of the principal metrics used to assess the consequences of terrorist attacks. Hence, a detailed understanding of the variations in public confidence among individuals, terrorist event types, and as a function of time is critical to developing this metric. In this exploratory study, a questionnaire was designed, tested, and administered to small groups of individuals to measure public confidence in the ability of federal, state, and local governments and their public safety agencies to prevent acts of terrorism. Data was collected from three groups before and after they watched mock television news broadcasts portraying a smallpox attack, a series of suicide bomber attacks, a refinery explosion attack, and cyber intrusions on financial institutions, resulting in identity theft. Our findings are: (a) although the aggregate confidence level is low, there are optimists and pessimists; (b) the subjects are discriminating in interpreting the nature of a terrorist attack, the time horizon, and its impact; (c) confidence recovery after a terrorist event has an incubation period; and (d) the patterns of recovery of confidence of the optimists and the pessimists are different. These findings can affect the strategy and policies to manage public confidence after a terrorist event.

  12. Functional Dissociation of Confident and Not-Confident Errors in the Spatial Delayed Response Task Demonstrates Impairments in Working Memory Encoding and Maintenance in Schizophrenia

    Directory of Open Access Journals (Sweden)

    Jutta S. Mayer

    2018-05-01

    Full Text Available Even though extensively investigated, the nature of working memory (WM deficits in patients with schizophrenia (PSZ is not yet fully understood. In particular, the contribution of different WM sub-processes to the severe WM deficit observed in PSZ is a matter of debate. So far, most research has focused on impaired WM maintenance. By analyzing different types of errors in a spatial delayed response task (DRT, we have recently demonstrated that incorrect yet confident responses (which we labeled as false memory errors rather than incorrect/not-confident responses reflect failures of WM encoding, which was also impaired in PSZ. In the present study, we provide further evidence for a functional dissociation between confident and not-confident errors by manipulating the demands on WM maintenance, i.e., the length over which information has to be maintained in WM. Furthermore, we investigate whether these functionally distinguishable WM processes are impaired in PSZ. Twenty-four PSZ and 24 demographically matched healthy controls (HC performed a spatial DRT in which the length of the delay period was varied between 1, 2, 4, and 6 s. In each trial, participants also rated their level of response confidence. Across both groups, longer delays led to increased rates of incorrect/not-confident responses, while incorrect/confident responses were not affected by delay length. This functional dissociation provides additional support for our proposal that false memory errors (i.e., confident errors reflect problems at the level of WM encoding, while not-confident errors reflect failures of WM maintenance. Schizophrenic patients showed increased numbers of both confident and not-confident errors, suggesting that both sub-processes of WM—encoding and maintenance—are impaired in schizophrenia. Combined with the delay length-dependent functional dissociation, we propose that these impairments in schizophrenic patients are functionally distinguishable.

  13. Matematica 2. Manual do Professor (Mathematics 2. Teacher's Manual).

    Science.gov (United States)

    D'Alu, Maria Jose Miranda de Sousa

    This teacher's manual accompanies a mathematics textbook for second graders, written in Portuguese. Developed from objectives set forth by the National Portuguese Materials Development Center, it follows closely the objectives and methodology of major curricula used in schools of the United States. Consideration was given to the Portuguese child's…

  14. Effects of confidence and anxiety on flow state in competition.

    Science.gov (United States)

    Koehn, Stefan

    2013-01-01

    Confidence and anxiety are important variables that underlie the experience of flow in sport. Specifically, research has indicated that confidence displays a positive relationship and anxiety a negative relationship with flow. The aim of this study was to assess potential direct and indirect effects of confidence and anxiety dimensions on flow state in tennis competition. A sample of 59 junior tennis players completed measures of Competitive State Anxiety Inventory-2d and Flow State Scale-2. Following predictive analysis, results showed significant positive correlations between confidence (intensity and direction) and anxiety symptoms (only directional perceptions) with flow state. Standard multiple regression analysis indicated confidence as the only significant predictor of flow. The results confirmed a protective function of confidence against debilitating anxiety interpretations, but there were no significant interaction effects between confidence and anxiety on flow state.

  15. Comparison of human septal nuclei MRI measurements using automated segmentation and a new manual protocol based on histology

    Science.gov (United States)

    Butler, Tracy; Zaborszky, Laszlo; Pirraglia, Elizabeth; Li, Jinyu; Wang, Xiuyuan Hugh; Li, Yi; Tsui, Wai; Talos, Delia; Devinsky, Orrin; Kuchna, Izabela; Nowicki, Krzysztof; French, Jacqueline; Kuzniecky, Rubin; Wegiel, Jerzy; Glodzik, Lidia; Rusinek, Henry; DeLeon, Mony J.; Thesen, Thomas

    2014-01-01

    Septal nuclei, located in basal forebrain, are strongly connected with hippocampi and important in learning and memory, but have received limited research attention in human MRI studies. While probabilistic maps for estimating septal volume on MRI are now available, they have not been independently validated against manual tracing of MRI, typically considered the gold standard for delineating brain structures. We developed a protocol for manual tracing of the human septal region on MRI based on examination of neuroanatomical specimens. We applied this tracing protocol to T1 MRI scans (n=86) from subjects with temporal epilepsy and healthy controls to measure septal volume. To assess the inter-rater reliability of the protocol, a second tracer used the same protocol on 20 scans that were randomly selected from the 72 healthy controls. In addition to measuring septal volume, maximum septal thickness between the ventricles was measured and recorded. The same scans (n=86) were also analysed using septal probabilistic maps and Dartel toolbox in SPM. Results show that our manual tracing algorithm is reliable, and that septal volume measurements obtained via manual and automated methods correlate significantly with each other (pautomated methods detected significantly enlarged septal nuclei in patients with temporal lobe epilepsy in accord with a proposed compensatory neuroplastic process related to the strong connections between septal nuclei and hippocampi. Septal thickness, which was simple to measure with excellent inter-rater reliability, correlated well with both manual and automated septal volume, suggesting it could serve as an easy-to-measure surrogate for septal volume in future studies. Our results call attention to the important though understudied human septal region, confirm its enlargement in temporal lobe epilepsy, and provide a reliable new manual delineation protocol that will facilitate continued study of this critical region. PMID:24736183

  16. Preservice teachers' perceived confidence in teaching school violence prevention.

    Science.gov (United States)

    Kandakai, Tina L; King, Keith A

    2002-01-01

    To examine preservice teachers' perceived confidence in teaching violence prevention and the potential effect of violence-prevention training on preservice teachers' confidence in teaching violence prevention. Six Ohio universities participated in the study. More than 800 undergraduate and graduate students completed surveys. Violence-prevention training, area of certification, and location of student- teaching placement significantly influenced preservice teachers' perceived confidence in teaching violence prevention. Violence-prevention training positively influences preservice teachers' confidence in teaching violence prevention. The results suggest that such training should be considered as a requirement for teacher preparation programs.

  17. Self Confidence Spillovers and Motivated Beliefs

    DEFF Research Database (Denmark)

    Banerjee, Ritwik; Gupta, Nabanita Datta; Villeval, Marie Claire

    that success when competing in a task increases the performers’ self-confidence and competitiveness in the subsequent task. We also find that such spillovers affect the self-confidence of low-status individuals more than that of high-status individuals. Receiving good news under Affirmative Action, however......Is success in a task used strategically by individuals to motivate their beliefs prior to taking action in a subsequent, unrelated, task? Also, is the distortion of beliefs reinforced for individuals who have lower status in society? Conducting an artefactual field experiment in India, we show...

  18. Validity and reliability of chronic tic disorder and obsessive-compulsive disorder diagnoses in the Swedish National Patient Register.

    Science.gov (United States)

    Rück, Christian; Larsson, K Johan; Lind, Kristina; Perez-Vigil, Ana; Isomura, Kayoko; Sariaslan, Amir; Lichtenstein, Paul; Mataix-Cols, David

    2015-06-22

    The usefulness of cases diagnosed in administrative registers for research purposes is dependent on diagnostic validity. This study aimed to investigate the validity and inter-rater reliability of recorded diagnoses of tic disorders and obsessive-compulsive disorder (OCD) in the Swedish National Patient Register (NPR). Chart review of randomly selected register cases and controls. 100 tic disorder cases and 100 OCD cases were randomly selected from the NPR based on codes from the International Classification of Diseases (ICD) 8th, 9th and 10th editions, together with 50 epilepsy and 50 depression control cases. The obtained psychiatric records were blindly assessed by 2 senior psychiatrists according to the criteria of the fourth edition of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) and ICD-10. Positive predictive value (PPV; cases diagnosed correctly divided by the sum of true positives and false positives). Between 1969 and 2009, the NPR included 7286 tic disorder and 24,757 OCD cases. The vast majority (91.3% of tic cases and 80.1% of OCD cases) are coded with the most recent ICD version (ICD-10). For tic disorders, the PPV was high across all ICD versions (PPV=89% in ICD-8, 86% in ICD-9 and 97% in ICD-10). For OCD, only ICD-10 codes had high validity (PPV=91-96%). None of the epilepsy or depression control cases were wrongly diagnosed as having tic disorders or OCD, respectively. Inter-rater reliability was outstanding for both tic disorders (κ=1) and OCD (κ=0.98). The validity and reliability of ICD codes for tic disorders and OCD in the Swedish NPR is generally high. We propose simple algorithms to further increase the confidence in the validity of these codes for epidemiological research. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Reliable and valid assessment of performance in thoracoscopy

    DEFF Research Database (Denmark)

    Konge, Lars; Lehnert, Per; Hansen, Henrik Jessen

    2012-01-01

    BACKGROUND: As we move toward competency-based education in medicine, we have lagged in developing competency-based evaluation methods. In the era of minimally invasive surgery, there is a need for a reliable and valid tool dedicated to measure competence in video-assisted thoracoscopic surgery....... The purpose of this study is to create such an assessment tool, and to explore its reliability and validity. METHODS: An expert group of physicians created an assessment tool consisting of 10 items rated on a five-point rating scale. The following factors were included: economy and confidence of movement...

  20. Software-assisted quantitative analysis of small bowel motility compared to manual measurements

    International Nuclear Information System (INIS)

    Bickelhaupt, S.; Froehlich, J.M.; Cattin, R.; Raible, S.; Bouquet, H.; Bill, U.; Patak, M.A.

    2014-01-01

    Aim: To validate a newly developed software prototype that automatically analyses small bowel motility by comparing it directly with manual measurement. Material and methods: Forty-five patients with clinical indication for small bowel magnetic resonance imaging (MRI) were retrospectively included in this institutional review board-approved study. MRI was performed using a 1.5 T system following a standard MR-enterography protocol. Small bowel motility parameters (contractions-per-minute, luminal diameter, amplitude) were measured three times each in identical segments using the manual and the semiautomatic software-assisted method. The methods were compared for agreement, repeatability, and time needed for each measurement. All parameters were compared between the methods. Results: A total of 91 small-bowel segments were analysed. No significant intra-individual difference (p > 0.05) was found for peristaltic frequencies between the methods (mean: 4.14/min manual; 4.22/min software-assisted). Amplitudes (5.14 mm; 5.57 mm) and mean lumen diameters (17.39 mm; 14.68) differed due to systematic differences in the definition of the bowel wall. Mean duration of single measurement was significantly (p < 0.01) shorter with the software (6.25 min; 1.30 min). The scattering of repeated measurements was significantly (p < 0.05) lower using the software. Conclusion: The software-assisted method accomplished highly reliable, fast and accurate measurement of small bowel motility. Measurement precision and duration differed significantly between the two methods in favour of the software-assisted technique

  1. Alternative confidence measure for local matching stereo algorithms

    CSIR Research Space (South Africa)

    Ndhlovu, T

    2009-11-01

    Full Text Available The authors present a confidence measure applied to individual disparity estimates in local matching stereo correspondence algorithms. It aims at identifying textureless areas, where most local matching algorithms fail. The confidence measure works...

  2. Coping skills: role of trait sport confidence and trait anxiety.

    Science.gov (United States)

    Cresswell, Scott; Hodge, Ken

    2004-04-01

    The current research assesses relationships among coping skills, trait sport confidence, and trait anxiety. Two samples (n=47 and n=77) of international competitors from surf life saving (M=23.7 yr.) and touch rugby (M=26.2 yr.) completed the Athletic Coping Skills Inventory, Trait Sport Confidence Inventory, and Sport Anxiety Scale. Analysis yielded significant correlations amongst trait anxiety, sport confidence, and coping. Specifically confidence scores were positively associated with coping with adversity scores and anxiety scores were negatively associated. These findings support the inclusion of the personality characteristics of confidence and anxiety within the coping model presented by Hardy, Jones, and Gould, Researchers should be aware that confidence and anxiety may influence the coping processes of athletes.

  3. Study of developing nuclear fabrication facility's integrated emergency response manual

    International Nuclear Information System (INIS)

    Kim, Taeh Yeong; Cho, Nam Chan; Han, Seung Hoon; Moon, Jong Han; Lee, Jin Hang; Min, Guem Young; Han, Ji Ah

    2016-01-01

    Public begin to pay attention to emergency management. Thus, public's consensus on having high level of emergency management system up to advanced country's is reached. In this social atmosphere, manual is considered as key factor to prevent accident or secure business continuity. Therefore, we first define possible crisis at KEPCO Nuclear Fuel (hereinafter KNF) and also make a 'Reaction List' for each crisis situation at the view of information-design. To achieve it, we analyze several country's crisis response manual and then derive component, indicate duties and roles at the information-design point of view. From this, we suggested guideline to make 'Integrated emergency response manual(IERM)'. The manual we used before have following few problems; difficult to applicate at the site, difficult to deliver information. To complement these problems, we searched manual elements from the view of information-design. As a result, we develop administrative manual. Although, this manual could be thought as fragmentary manual because it confined specific several agency/organization and disaster type

  4. Hanford Waste Vitrification Plant technical manual

    Energy Technology Data Exchange (ETDEWEB)

    Larson, D.E. [ed.; Watrous, R.A.; Kruger, O.L. [and others

    1996-03-01

    A key element of the Hanford waste management strategy is the construction of a new facility, the Hanford Waste Vitrification Plant (HWVP), to vitrify existing and future liquid high-level waste produced by defense activities at the Hanford Site. The HWVP mission is to vitrify pretreated waste in borosilicate glass, cast the glass into stainless steel canisters, and store the canisters at the Hanford Site until they are shipped to a federal geological repository. The HWVP Technical Manual (Manual) documents the technical bases of the current HWVP process and provides a physical description of the related equipment and the plant. The immediate purpose of the document is to provide the technical bases for preparation of project baseline documents that will be used to direct the Title 1 and Title 2 design by the A/E, Fluor. The content of the Manual is organized in the following manner. Chapter 1.0 contains the background and context within which the HWVP was designed. Chapter 2.0 describes the site, plant, equipment and supporting services and provides the context for application of the process information in the Manual. Chapter 3.0 provides plant feed and product requirements, which are primary process bases for plant operation. Chapter 4.0 summarizes the technology for each plant process. Chapter 5.0 describes the engineering principles for designing major types of HWVP equipment. Chapter 6.0 describes the general safety aspects of the plant and process to assist in safe and prudent facility operation. Chapter 7.0 includes a description of the waste form qualification program and data. Chapter 8.0 indicates the current status of quality assurance requirements for the Manual. The Appendices provide data that are too extensive to be placed in the main text, such as extensive tables and sets of figures. The Manual is a revision of the 1987 version.

  5. Hanford Waste Vitrification Plant technical manual

    International Nuclear Information System (INIS)

    Larson, D.E.; Watrous, R.A.; Kruger, O.L.

    1996-03-01

    A key element of the Hanford waste management strategy is the construction of a new facility, the Hanford Waste Vitrification Plant (HWVP), to vitrify existing and future liquid high-level waste produced by defense activities at the Hanford Site. The HWVP mission is to vitrify pretreated waste in borosilicate glass, cast the glass into stainless steel canisters, and store the canisters at the Hanford Site until they are shipped to a federal geological repository. The HWVP Technical Manual (Manual) documents the technical bases of the current HWVP process and provides a physical description of the related equipment and the plant. The immediate purpose of the document is to provide the technical bases for preparation of project baseline documents that will be used to direct the Title 1 and Title 2 design by the A/E, Fluor. The content of the Manual is organized in the following manner. Chapter 1.0 contains the background and context within which the HWVP was designed. Chapter 2.0 describes the site, plant, equipment and supporting services and provides the context for application of the process information in the Manual. Chapter 3.0 provides plant feed and product requirements, which are primary process bases for plant operation. Chapter 4.0 summarizes the technology for each plant process. Chapter 5.0 describes the engineering principles for designing major types of HWVP equipment. Chapter 6.0 describes the general safety aspects of the plant and process to assist in safe and prudent facility operation. Chapter 7.0 includes a description of the waste form qualification program and data. Chapter 8.0 indicates the current status of quality assurance requirements for the Manual. The Appendices provide data that are too extensive to be placed in the main text, such as extensive tables and sets of figures. The Manual is a revision of the 1987 version

  6. Reclaim your creative confidence.

    Science.gov (United States)

    Kelley, Tom; Kelley, David

    2012-12-01

    Most people are born creative. But over time, a lot of us learn to stifle those impulses. We become warier of judgment, more cautious more analytical. The world seems to divide into "creatives" and "noncreatives," and too many people resign themselves to the latter category. And yet we know that creativity is essential to success in any discipline or industry. The good news, according to authors Tom Kelley and David Kelley of IDEO, is that we all can rediscover our creative confidence. The trick is to overcome the four big fears that hold most of us back: fear of the messy unknown, fear of judgment, fear of the first step, and fear of losing control. The authors use an approach based on the work of psychologist Albert Bandura in helping patients get over their snake phobias: You break challenges down into small steps and then build confidence by succeeding on one after another. Creativity is something you practice, say the authors, not just a talent you are born with.

  7. Factors affecting midwives' confidence in intrapartum care: a phenomenological study.

    Science.gov (United States)

    Bedwell, Carol; McGowan, Linda; Lavender, Tina

    2015-01-01

    midwives are frequently the lead providers of care for women throughout labour and birth. In order to perform their role effectively and provide women with the choices they require midwives need to be confident in their practice. This study explores factors which may affect midwives' confidence in their practice. hermeneutic phenomenology formed the theoretical basis for the study. Prospective longitudinal data collection was completed using diaries and semi-structured interviews. Twelve midwives providing intrapartum care in a variety of settings were recruited to ensure a variety of experiences in different contexts were captured. the principal factor affecting workplace confidence, both positively and negatively, was the influence of colleagues. Perceived autonomy and a sense of familiarity could also enhance confidence. However, conflict in the workplace was a critical factor in reducing midwives' confidence. Confidence was an important, but fragile, phenomenon to midwives and they used a variety of coping strategies, emotional intelligence and presentation management to maintain it. this is the first study to highlight both the factors influencing midwives' workplace confidence and the strategies midwives employed to maintain their confidence. Confidence is important in maintaining well-being and workplace culture may play a role in explaining the current low morale within the midwifery workforce. This may have implications for women's choices and care. Support, effective leadership and education may help midwives develop and sustain a positive sense of confidence. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Development of a reliable, valid measure to assess parents' and teachers' understanding of postural care for children with physical disabilities: the (UKC PostCarD) questionnaire.

    Science.gov (United States)

    Hotham, S; Hutton, E; Hamilton-West, K E

    2015-11-01

    Previous research has highlighted lack of knowledge, understanding and confidence among parents and teachers responsible for the postural care of children with physical disability. Interventions designed to improve these qualities require a reliable and validated tool to assess pre- and post-intervention levels. Currently, however, no validated measure of postural care confidence (i.e. self-efficacy) exists. Hence, the aim of this research was to develop a reliable and valid questionnaire to assess parents' and teachers' confidence, alongside knowledge and understanding of postural care - the Understanding Knowledge and Confidence in providing POSTural CARe for children with Disabilities (UKC PostCarD) questionnaire. Items were developed by a multidisciplinary team and designed to map onto the content of 'An A-to-Z of Postural Care'. Parents, teachers and therapists assessed items for face validity. Scale reliability was then assessed using Cronbach's alpha and known-group validity was assessed by comparing scores of an 'expert' group (physiotherapists and occupational therapists) with those of a 'non-expert' group (with no formal training in postural care). The total scale and all three subscales (understanding and knowledge, confidence and concerns) demonstrated adequate reliability (α > 0.83) and subscale correlations formed a logical pattern (understanding and knowledge correlated positively with confidence and negatively with concerns). Experts' (n = 111) scores were higher than non-experts' (n = 79) for the total scale and all subscales (P children with disabilities. © 2015 John Wiley & Sons Ltd.

  9. Dynamic delivery of the National Transit Database Sampling Manual.

    Science.gov (United States)

    2013-02-01

    This project improves the National Transit Database (NTD) Sampling Manual and develops an Internet-based, WordPress-powered interactive Web tool to deliver the new NTD Sampling Manual dynamically. The new manual adds guidance and a tool for transit a...

  10. nigerian students' self-confidence in responding to statements

    African Journals Online (AJOL)

    Temechegn

    Altogether the test is made up of 40 items covering students' ability to recall definition ... confidence interval within which student have confidence in their choice of the .... is mentioned these equilibrium systems come to memory of the learner.

  11. Conquering Credibility for Monetary Policy Under Sticky Confidence

    Directory of Open Access Journals (Sweden)

    Jaylson Jair da Silveira

    2015-06-01

    Full Text Available We derive a best-reply monetary policy when the confidence by price setters on the monetary authority’s commitment to price level targeting may be both incomplete and sticky. We find that complete confidence (or full credibility is not a necessary condition for the achievement of a price level target even when heterogeneity in firms’ price level expectations is endogenously time-varying and may emerge as a long-run equilibrium outcome. In fact, in the absence of exogenous perturbations to the dynamic of confidence building, it is the achievement of a price level target for long enough that, due to stickiness in the state of confidence, rather ensures the conquering of full credibility. This result has relevant implications for the conduct of monetary policy in pursuit of price stability. One implication is that setting a price level target matters more as a means to provide monetary policy with a sharper focus on price stability than as a device to conquer credibility. As regards the conquering of credibility for monetary policy, it turns out that actions speak louder than words, as the continuing achievement of price stability is what ultimately performs better as a confidence-building device.

  12. Hoisting and rigging manual: Uncontrolled document

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-05-01

    This document is a draft copy of a Hoisting and Rigging Manual for the Department of Energy. The manual is divided into ten chapters. The chapter titles follow: terminology and definitions; operator training and qualification; overhead and gantry cranes; mobile cranes; forklift trucks; hoists; hooks; wire rope, slings, and rigging accessories; construction hoisting and rigging equipment requirements; references.

  13. Requirements to be met by the operation manual

    International Nuclear Information System (INIS)

    1981-03-01

    The rule applies to the contents and the lay-out of the operating manual for stationary nuclear power plants. The draft contains: 1. General requirement to be met by the contents of the operating manual. The operating manual to be arranged in 4 parts (part 1: internal rules and regulations; part 2: operation overall plant; part 3: incidents; part 4: operation systems). Safety specifications to be included in the manual, the exemption being the system of technical documentation. 2. General requirements to be met by the lay-out of the operating manual. Comprehensibility; legibility; structure and subdivisions; arrangement of the instructions and design of the manuals cover. 3. Requirements to be met by part 1. Defining the various internal rules and regulations (personnel management); rules and regulations concerning inspections and shift work; maintenance and repair; radiation protection; guard duty and admission; alarm; fire protection; first aid. 4. Requirements to be met by part 2. Provisions and operational limitations; limit values important from the point of view of safety; normal operation; anomalous operation; in-service inspections. 6. Requirements to be met by part 3. 7. Annex: Rules, regulations and stipulations mentioned in the rule draft. (orig.)

  14. The antecedents and belief-polarized effects of thought confidence.

    Science.gov (United States)

    Chou, Hsuan-Yi; Lien, Nai-Hwa; Liang, Kuan-Yu

    2011-01-01

    This article investigates 2 possible antecedents of thought confidence and explores the effects of confidence induced before or during ad exposure. The results of the experiments indicate that both consumers' dispositional optimism and spokesperson attractiveness have significant effects on consumers' confidence in thoughts that are generated after viewing the advertisement. Higher levels of thought confidence will influence the quality of the thoughts that people generate, lead to either positively or negatively polarized message processing, and therefore induce better or worse advertising effectiveness, depending on the valence of thoughts. The authors posit the belief-polarization hypothesis to explain these findings.

  15. Mechanical versus manual chest compressions for cardiac arrest.

    Science.gov (United States)

    Brooks, Steven C; Hassan, Nizar; Bigham, Blair L; Morrison, Laurie J

    2014-02-27

    This is the first update of the Cochrane review on mechanical chest compression devices published in 2011 (Brooks 2011). Mechanical chest compression devices have been proposed to improve the effectiveness of cardiopulmonary resuscitation (CPR). To assess the effectiveness of mechanical chest compressions versus standard manual chest compressions with respect to neurologically intact survival in patients who suffer cardiac arrest. We searched the Cochrane Central Register of Controlled Studies (CENTRAL; 2013, Issue 12), MEDLINE Ovid (1946 to 2013 January Week 1), EMBASE (1980 to 2013 January Week 2), Science Citation abstracts (1960 to 18 November 2009), Science Citation Index-Expanded (SCI-EXPANDED) (1970 to 11 January 2013) on Thomson Reuters Web of Science, biotechnology and bioengineering abstracts (1982 to 18 November 2009), conference proceedings Citation Index-Science (CPCI-S) (1990 to 11 January 2013) and clinicaltrials.gov (2 August 2013). We applied no language restrictions. Experts in the field of mechanical chest compression devices and manufacturers were contacted. We included randomised controlled trials (RCTs), cluster RCTs and quasi-randomised studies comparing mechanical chest compressions versus manual chest compressions during CPR for patients with atraumatic cardiac arrest. Two review authors abstracted data independently; disagreement between review authors was resolved by consensus and by a third review author if consensus could not be reached. The methodologies of selected studies were evaluated by a single author for risk of bias. The primary outcome was survival to hospital discharge with good neurological outcome. We planned to use RevMan 5 (Version 5.2. The Nordic Cochrane Centre) and the DerSimonian & Laird method (random-effects model) to provide a pooled estimate for risk ratio (RR) with 95% confidence intervals (95% CIs), if data allowed. Two new studies were included in this update. Six trials in total, including data from 1166

  16. Accountability methods for plutonium and uranium: the NRC manuals

    Energy Technology Data Exchange (ETDEWEB)

    Gutmacher, R.G.; Stephens, F.B.

    1977-09-28

    Four manuals containing methods for the accountability of plutonium nitrate solutions, plutonium dioxide, uranium dioxide and mixed uranium-plutonium oxide have been prepared by us and issued by the U.S. Nuclear Regulatory Commission. A similar manual on methods for the accountability of uranium and plutonium in reprocessing plant dissolver solutions is now in preparation. In the present paper, we discuss the contents of the previously issued manuals and give a preview of the manual now being prepared.

  17. Accountability methods for plutonium and uranium: the NRC manuals

    International Nuclear Information System (INIS)

    Gutmacher, R.G.; Stephens, F.B.

    1977-01-01

    Four manuals containing methods for the accountability of plutonium nitrate solutions, plutonium dioxide, uranium dioxide and mixed uranium-plutonium oxide have been prepared by us and issued by the U.S. Nuclear Regulatory Commission. A similar manual on methods for the accountability of uranium and plutonium in reprocessing plant dissolver solutions is now in preparation. In the present paper, we discuss the contents of the previously issued manuals and give a preview of the manual now being prepared

  18. Netbooks The Missing Manual

    CERN Document Server

    Biersdorfer, J

    2009-01-01

    Netbooks are the hot new thing in PCs -- small, inexpensive laptops designed for web browsing, email, and working with web-based programs. But chances are you don't know how to choose a netbook, let alone use one. Not to worry: with this Missing Manual, you'll learn which netbook is right for you and how to set it up and use it for everything from spreadsheets for work to hobbies like gaming and photo sharing. Netbooks: The Missing Manual provides easy-to-follow instructions and lots of advice to help you: Learn the basics for using a Windows- or Linux-based netbookConnect speakers, printe

  19. Radiological control technician: Training program management manual

    International Nuclear Information System (INIS)

    1992-10-01

    This manual defines and describes the DOE Radiological Control Technician Core Training Program qualification and training process, material development requirements, standards and policies, and administration. The manual applies to Radiological Control Technician Training Programs at all DOE contractor sites

  20. Free manual of cadaver dissection modifiable by other anatomists.

    Science.gov (United States)

    Chung, Beom Sun; Chung, Min Suk

    2015-06-01

    Even in the rapidly changing field of cadaver dissection, published guide books still play an important role in the anatomy lab. However, commercial manuals with lengthy volumes and inflexible copyrights have several limitations which can be complemented by open-source manuals. Recently, the authors have manufactured and distributed a free electronic dissection manual (anatomy.co.kr), where descriptions are written concisely and images are drawn schematically. Moreover, simplified signs are employed to represent the cadaver viewing angles and manner of dissection. Based on the original files of this manual, other anatomists can revise and utilize the descriptions and figures. We expect many updated versions of our manual to be shared between students all over the world.