WorldWideScience

Sample records for conduits

  1. Conduit Stability and Collapse in Explosive Volcanic Eruptions: Coupling Conduit Flow and Failure Models

    Science.gov (United States)

    Mullet, B.; Segall, P.

    2017-12-01

    Explosive volcanic eruptions can exhibit abrupt changes in physical behavior. In the most extreme cases, high rates of mass discharge are interspaced by dramatic drops in activity and periods of quiescence. Simple models predict exponential decay in magma chamber pressure, leading to a gradual tapering of eruptive flux. Abrupt changes in eruptive flux therefore indicate that relief of chamber pressure cannot be the only control of the evolution of such eruptions. We present a simplified physics-based model of conduit flow during an explosive volcanic eruption that attempts to predict stress-induced conduit collapse linked to co-eruptive pressure loss. The model couples a simple two phase (gas-melt) 1-D conduit solution of the continuity and momentum equations with a Mohr-Coulomb failure condition for the conduit wall rock. First order models of volatile exsolution (i.e. phase mass transfer) and fragmentation are incorporated. The interphase interaction force changes dramatically between flow regimes, so smoothing of this force is critical for realistic results. Reductions in the interphase force lead to significant relative phase velocities, highlighting the deficiency of homogenous flow models. Lateral gas loss through conduit walls is incorporated using a membrane-diffusion model with depth dependent wall rock permeability. Rapid eruptive flux results in a decrease of chamber and conduit pressure, which leads to a critical deviatoric stress condition at the conduit wall. Analogous stress distributions have been analyzed for wellbores, where much work has been directed at determining conditions that lead to wellbore failure using Mohr-Coulomb failure theory. We extend this framework to cylindrical volcanic conduits, where large deviatoric stresses can develop co-eruptively leading to multiple distinct failure regimes depending on principal stress orientations. These failure regimes are categorized and possible implications for conduit flow are discussed, including

  2. Stochastic simulation of karst conduit networks

    Science.gov (United States)

    Pardo-Igúzquiza, Eulogio; Dowd, Peter A.; Xu, Chaoshui; Durán-Valsero, Juan José

    2012-01-01

    Karst aquifers have very high spatial heterogeneity. Essentially, they comprise a system of pipes (i.e., the network of conduits) superimposed on rock porosity and on a network of stratigraphic surfaces and fractures. This heterogeneity strongly influences the hydraulic behavior of the karst and it must be reproduced in any realistic numerical model of the karst system that is used as input to flow and transport modeling. However, the directly observed karst conduits are only a small part of the complete karst conduit system and knowledge of the complete conduit geometry and topology remains spatially limited and uncertain. Thus, there is a special interest in the stochastic simulation of networks of conduits that can be combined with fracture and rock porosity models to provide a realistic numerical model of the karst system. Furthermore, the simulated model may be of interest per se and other uses could be envisaged. The purpose of this paper is to present an efficient method for conditional and non-conditional stochastic simulation of karst conduit networks. The method comprises two stages: generation of conduit geometry and generation of topology. The approach adopted is a combination of a resampling method for generating conduit geometries from templates and a modified diffusion-limited aggregation method for generating the network topology. The authors show that the 3D karst conduit networks generated by the proposed method are statistically similar to observed karst conduit networks or to a hypothesized network model. The statistical similarity is in the sense of reproducing the tortuosity index of conduits, the fractal dimension of the network, the direction rose of directions, the Z-histogram and Ripley's K-function of the bifurcation points (which differs from a random allocation of those bifurcation points). The proposed method (1) is very flexible, (2) incorporates any experimental data (conditioning information) and (3) can easily be modified when

  3. Optimization of Design of Steam Turbine Exhaust Conduits

    Directory of Open Access Journals (Sweden)

    A. S. Goldin

    2014-01-01

    Full Text Available Improving effectiveness turbine was and remains a key issue for today. In order to improve the efficiency of the turbine is necessary to reduce losses in the steam turbine exhaust conduit.This paper presents the design optimization exhaust conduit steam turbine K-27-2.9 produced by JSC «KTW» at the design stage. The aims of optimizing the design were: decreasing hydraulic resistance of the conduit, reduction of non-uniformity of the flow at the outlet of the conduit, equalizing steam flow ahead of the condenser tube bundle.The conduit models were made and flows in it were simulated in environment of the Solid Works and its application COSMOS Flo Works.As the initial conduit model was selected exhaust conduit of turbine PT-25/34-3.4 produced by JSC «KTW». Was obtained by the calculated velocity field at the outlet of the conduit. The analysis of the calculation results revealed the necessity of changes to the initial design of the conduit. The changes were accompanied by calculating currents flow in the conduit, and assessed the impact of design changes on the nature of the course. Further transformation of the construction of the conduit was held on the results of these calculations. Construction changes are not touched by the outer geometry of the conduit, and were introduced to meet technological.According to calculation results, conclusions were drawn and selected three versions of the conduit.Given are the research results for the initial conduit model and modified design versions. In order to evaluate the flow degree of irregularity the momentum factor (Bussinesku factor for outlet crosssection of the selected conduit design version. Analysis of the research results made it possible to determine optimum design of the exhaust conduit.Introducing the suggested alterations in the conduit design will result in improvement of heat exchange in the condenser, an increase in reliability of the tube bundle operation, a decrease in noise and

  4. Conduit enlargement in an eogenetic karst aquifer

    Science.gov (United States)

    Moore, Paul J.; Martin, Jonathan B.; Screaton, Elizabeth J.; Neuhoff, Philip S.

    2010-11-01

    SummaryMost concepts of conduit development have focused on telogenetic karst aquifers, where low matrix permeability focuses flow and dissolution along joints, fractures, and bedding planes. However, conduits also exist in eogenetic karst aquifers, despite high matrix permeability which accounts for a significant component of flow. This study investigates dissolution within a 6-km long conduit system in the eogenetic Upper Floridan aquifer of north-central Florida that begins with a continuous source of allogenic recharge at the Santa Fe River Sink and discharges from a first-magnitude spring at the Santa Fe River Rise. Three sources of water to the conduit include the allogenic recharge, diffuse recharge through epikarst, and mineralized water upwelling from depth. Results of sampling and inverse modeling using PHREEQC suggest that dissolution within the conduit is episodic, occurring only during 30% of 16 sampling times between March 2003 and April 2007. During low flow conditions, carbonate saturated water flows from the matrix to the conduit, restricting contact between undersaturated allogenic water with the conduit wall. When gradients reverse during high flow conditions, undersaturated allogenic recharge enters the matrix. During these limited periods, estimates of dissolution within the conduit suggest wall retreat averages about 4 × 10 -6 m/day, in agreement with upper estimates of maximum wall retreat for telogenetic karst. Because dissolution is episodic, time-averaged dissolution rates in the sink-rise system results in a wall retreat rate of about 7 × 10 -7 m/day, which is at the lower end of wall retreat for telogenetic karst. Because of the high permeability matrix, conduits in eogenetic karst thus enlarge not just at the walls of fractures or pre-existing conduits such as those in telogenetic karst, but also may produce a friable halo surrounding the conduits that may be removed by additional mechanical processes. These observations stress the

  5. The corrosion effect on the conduit systems

    International Nuclear Information System (INIS)

    Laaidi, Naouar; Belattar, Sougratti

    2009-01-01

    The conduits in the buildings require a regular and permanent control, in order to avoid the risks of deterioration caused by the corrosion or the escape of water. In this work, we present a thermal nondestructive testing method of concrete structures containing water conduits, based on numerical modeling in three dimensions. The goal is to study the detectability of these conduits in different situations and to give a thermal characterization of the rust behaviour in the steel conduits. (author)

  6. Bentall Operation with Valved Homograft Conduit

    Science.gov (United States)

    Choudhary, Shiv K.; Talwar, Sachin; Kumar, A. Sampath

    2000-01-01

    Lesions of the ascending aorta associated with aortic valve disease are usually treated by implanting a prosthetic valved conduit (Bentall procedure). In this report, we present our experience in which a valved homograft conduit was used for the procedure. Six patients underwent a Bentall procedure with the use of a cryopreserved valved homograft conduit. Two of the patients had annuloaortic ectasia, 2 had Marfan syndrome, and 1 had an atherosclerotic aneurysm of the aorta. One patient had severe aortic stenosis due to a bicuspid aortic valve, along with an aneurysm and localized dissection of the ascending aorta. In all of the patients, the aortic annulus was substantially dilated, with accompanying moderate-to-severe aortic regurgitation. A standard procedure was performed with moderate hypothermia, cardiopulmonary bypass, and aortic and bicaval cannulation. The ascending aorta and the aortic valve were replaced with a cryopreserved valved homograft conduit (aortic in 5 patients and pulmonary in 1). The native coronary ostia were anastomosed directly to the homograft. Echocardiography, which was performed intraoperatively, before discharge from the hospital, and at follow-up visits (1 to 36 months), revealed good valve function without dilatation of the homograft conduits. There was 1 late death due to Aspergillus fumigatus endocarditis, 6 months postoperatively. In 1 patient, magnetic resonance imaging performed at 24 months revealed normal caliber of the homograft conduit. We conclude that the Bentall procedure can be performed, safely and with excellent results, using cryopreserved homograft conduits. PMID:11198310

  7. Biological conduit small gap sleeve bridging method for peripheral nerve injury: regeneration law of nerve fibers in the conduit

    Directory of Open Access Journals (Sweden)

    Pei-xun Zhang

    2015-01-01

    Full Text Available The clinical effects of 2-mm small gap sleeve bridging of the biological conduit to repair peripheral nerve injury are better than in the traditional epineurium suture, so it is possible to replace the epineurium suture in the treatment of peripheral nerve injury. This study sought to identify the regeneration law of nerve fibers in the biological conduit. A nerve regeneration chamber was constructed in models of sciatic nerve injury using 2-mm small gap sleeve bridging of a biodegradable biological conduit. The results showed that the biological conduit had good histocompatibility. Tissue and cell apoptosis in the conduit apparently lessened, and regenerating nerve fibers were common. The degeneration regeneration law of Schwann cells and axons in the conduit was quite different from that in traditional epineurium suture. During the prime period for nerve fiber regeneration (2-8 weeks, the number of Schwann cells and nerve fibers was higher in both proximal and distal ends, and the effects of the small gap sleeve bridging method were better than those of the traditional epineurium suture. The above results provide an objective and reliable theoretical basis for the clinical application of the biological conduit small gap sleeve bridging method to repair peripheral nerve injury.

  8. Drill pipes and casings utilizing multi-conduit tubulars

    Energy Technology Data Exchange (ETDEWEB)

    Curlett, H.B.

    1989-01-24

    A seal adapted for use with a multi-conduit well tubular, or the like, is described which consists of: a plate with fluid passages, each passage corresponding to an opening of a conduit of the multiconduit tubular, and a groove on the plate around each passage; and elastomer means partially embeddable into each groove for sealing each conduit of a tubular to a corresponding conduit of another similar tubular.

  9. Design of barrier coatings on kink-resistant peripheral nerve conduits

    Directory of Open Access Journals (Sweden)

    Basak Acan Clements

    2016-02-01

    Full Text Available Here, we report on the design of braided peripheral nerve conduits with barrier coatings. Braiding of extruded polymer fibers generates nerve conduits with excellent mechanical properties, high flexibility, and significant kink-resistance. However, braiding also results in variable levels of porosity in the conduit wall, which can lead to the infiltration of fibrous tissue into the interior of the conduit. This problem can be controlled by the application of secondary barrier coatings. Using a critical size defect in a rat sciatic nerve model, the importance of controlling the porosity of the nerve conduit walls was explored. Braided conduits without barrier coatings allowed cellular infiltration that limited nerve recovery. Several types of secondary barrier coatings were tested in animal studies, including (1 electrospinning a layer of polymer fibers onto the surface of the conduit and (2 coating the conduit with a cross-linked hyaluronic acid-based hydrogel. Sixteen weeks after implantation, hyaluronic acid-coated conduits had higher axonal density, displayed higher muscle weight, and better electrophysiological signal recovery than uncoated conduits or conduits having an electrospun layer of polymer fibers. This study indicates that braiding is a promising method of fabrication to improve the mechanical properties of peripheral nerve conduits and demonstrates the need to control the porosity of the conduit wall to optimize functional nerve recovery.

  10. 47 CFR 32.2441 - Conduit systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Conduit systems. 32.2441 Section 32.2441 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2441 Conduit systems. (a...

  11. Peripheral nerve conduits: technology update

    Science.gov (United States)

    Arslantunali, D; Dursun, T; Yucel, D; Hasirci, N; Hasirci, V

    2014-01-01

    Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS) and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers) and designs (tubular, fibrous, and matrix type) are being presented. PMID:25489251

  12. Artificial urinary conduit construction using tissue engineering methods.

    Science.gov (United States)

    Kloskowski, Tomasz; Pokrywczyńska, Marta; Drewa, Tomasz

    2015-01-01

    Incontinent urinary diversion using an ileal conduit is the most popular method used by urologists after bladder cystectomy resulting from muscle invasive bladder cancer. The use of gastrointestinal tissue is related to a series of complications with the necessity of surgical procedure extension which increases the time of surgery. Regenerative medicine together with tissue engineering techniques gives hope for artificial urinary conduit construction de novo without affecting the ileum. In this review we analyzed history of urinary diversion together with current attempts in urinary conduit construction using tissue engineering methods. Based on literature and our own experience we presented future perspectives related to the artificial urinary conduit construction. A small number of papers in the field of tissue engineered urinary conduit construction indicates that this topic requires more attention. Three main factors can be distinguished to resolve this topic: proper scaffold construction along with proper regeneration of both the urothelium and smooth muscle layers. Artificial urinary conduit has a great chance to become the first commercially available product in urology constructed by regenerative medicine methods.

  13. Flexible cryogenic conduit

    International Nuclear Information System (INIS)

    Brindza, P.D.; Wines, R.R.; Takacs, J.J.

    1999-01-01

    A flexible and relatively low cost cryogenic conduit is described. The flexible cryogenic conduit of the present invention comprises a first inner corrugated tube with single braided serving, a second outer corrugated tube with single braided serving concentric with the inner corrugated tube, and arranged outwardly about the periphery of the inner corrugated tube and between the inner and outer corrugated tubes: a superinsulation layer; a one half lap layer of polyester ribbon; a one half lap layer of copper ribbon; a spirally wound refrigeration tube; a second one half lap layer of copper ribbon; a second one half lap layer of polyester ribbon; a second superinsulation layer; a third one half lap layer of polyester ribbon; and a spirally wound stretchable and compressible filament

  14. Conduit for regeneration of biological material

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention relates to a conduit comprising a first material, having 1) a through-going hole, 2) fibers aligned along the long-axis in the through-going hole, each fiber having a diameter in the range 200-2000 nm. The conduit is preferably for regeneration of biological material, even...

  15. Drill pipes and casings utilizing multi-conduit tubular; Flerkanals roerstreng

    Energy Technology Data Exchange (ETDEWEB)

    Curlett, H.B.

    1997-04-23

    The invention relates to a multi-conduit tubular having fluid conduits and electrical conduits, with associated surface fluid and electrical commutators, and downhole sensors for providing surface monitors with instantaneous formation data. Each tubular includes a plurality of uniform linear conduits there through, with a gasket seal plate interposed between joined tubular for assuring a high pressure seal between joined conduits. the seal plate includes an intermediate electrical connector for connecting electrical conduit connectors of one tubular to another. A coupling collar with uniform diameter internal coarse and fine threads joins the tubular ends having similar threads by differential thread action without respective tubular rotation. Each tubular end includes an inter-engaging index recess and index lug, and drive recesses and lugs for maintaining angular registry of the tubular string and for driving one drill tubular with another. A fluid commutator includes a rotating shaft with passages connected to the tubular conduits, and rotating in a manifold having annular grooves in communication with the shaft passages and external fluid sources. An adaptor couples each commutator shaft passage to one or more tubular conduits. Slip rings on a quill shaft and stationary brush means provide electrical continuity from the electrical conduit wires to surface equipment. A cross-over sub includes formation parameter sensors and telemetry equipment in a blocked off portion of a fluid conduit. An annular accumulator connected with the well bore annulus applies a pressure thereto in response to downhole sensors to change the effective density of the drill mud. The multi-conduit tubular is further adapted for use as a well casing to provide downhole access of a plurality of fluids and electrical parameter sensors. 28 figs.

  16. Water Flow in Karst Aquifer Considering Dynamically Variable Saturation Conduit

    Science.gov (United States)

    Tan, Chaoqun; Hu, Bill X.

    2017-04-01

    The karst system is generally conceptualized as dual-porosity system, which is characterized by low conductivity and high storage continuum matrix and high conductivity and quick flow conduit networks. And so far, a common numerical model for simulating flow in karst aquifer is MODFLOW2005-CFP, which is released by USGS in 2008. However, the steady-state approach for conduit flow in CFP is physically impractical when simulating very dynamic hydraulics with variable saturation conduit. So, we adopt the method proposed by Reimann et al. (2011) to improve current model, in which Saint-Venant equations are used to model the flow in conduit. Considering the actual background that the conduit is very big and varies along flow path and the Dirichlet boundary varies with rainfall in our study area in Southwest China, we further investigate the influence of conduit diameter and outflow boundary on numerical model. And we also analyze the hydraulic process in multi-precipitation events. We find that the numerical model here corresponds well with CFP for saturated conduit, and it could depict the interaction between matrix and conduit during very dynamic hydraulics pretty well compare with CFP.

  17. 3D-engineering of Cellularized Conduits for Peripheral Nerve Regeneration

    Science.gov (United States)

    Hu, Yu; Wu, Yao; Gou, Zhiyuan; Tao, Jie; Zhang, Jiumeng; Liu, Qianqi; Kang, Tianyi; Jiang, Shu; Huang, Siqing; He, Jiankang; Chen, Shaochen; Du, Yanan; Gou, Maling

    2016-08-01

    Tissue engineered conduits have great promise for bridging peripheral nerve defects by providing physical guiding and biological cues. A flexible method for integrating support cells into a conduit with desired architectures is wanted. Here, a 3D-printing technology is adopted to prepare a bio-conduit with designer structures for peripheral nerve regeneration. This bio-conduit is consisted of a cryopolymerized gelatin methacryloyl (cryoGelMA) gel cellularized with adipose-derived stem cells (ASCs). By modeling using 3D-printed “lock and key” moulds, the cryoGelMA gel is structured into conduits with different geometries, such as the designed multichannel or bifurcating and the personalized structures. The cryoGelMA conduit is degradable and could be completely degraded in 2-4 months in vivo. The cryoGelMA scaffold supports the attachment, proliferation and survival of the seeded ASCs, and up-regulates the expression of their neurotrophic factors mRNA in vitro. After implanted in a rat model, the bio-conduit is capable of supporting the re-innervation across a 10 mm sciatic nerve gap, with results close to that of the autografts in terms of functional and histological assessments. The study describes an indirect 3D-printing technology for fabricating cellularized designer conduits for peripheral nerve regeneration, and could lead to the development of future nerve bio-conduits for clinical use.

  18. A novel conduit-based coaptation device for primary nerve repair.

    Science.gov (United States)

    Bamba, Ravinder; Riley, D Colton; Kelm, Nathaniel D; Cardwell, Nancy; Pollins, Alonda C; Afshari, Ashkan; Nguyen, Lyly; Dortch, Richard D; Thayer, Wesley P

    2018-06-01

    Conduit-based nerve repairs are commonly used for small nerve gaps, whereas primary repair may be performed if there is no tension on nerve endings. We hypothesize that a conduit-based nerve coaptation device will improve nerve repair outcomes by avoiding sutures at the nerve repair site and utilizing the advantages of a conduit-based repair. The left sciatic nerves of female Sprague-Dawley rats were transected and repaired using a novel conduit-based device. The conduit-based device group was compared to a control group of rats that underwent a standard end-to-end microsurgical repair of the sciatic nerve. Animals underwent behavioral assessments at weekly intervals post-operatively using the sciatic functional index (SFI) test. Animals were sacrificed at four weeks to obtain motor axon counts from immunohistochemistry. A sub-group of animals were sacrificed immediately post repair to obtain MRI images. SFI scores were superior in rats which received conduit-based repairs compared to the control group. Motor axon counts distal to the injury in the device group at four weeks were statistically superior to the control group. MRI tractography was used to demonstrate repair of two nerves using the novel conduit device. A conduit-based nerve coaptation device avoids sutures at the nerve repair site and leads to improved outcomes in a rat model. Conduit-based nerve repair devices have the potential to standardize nerve repairs while improving outcomes.

  19. In vitro evaluation of carbon-nanotube-reinforced bioprintable vascular conduits

    International Nuclear Information System (INIS)

    Dolati, Farzaneh; Yu, Yin; Zhang, Yahui; Ozbolat, Ibrahim T; Jesus, Aribet M De; Sander, Edward A

    2014-01-01

    Vascularization of thick engineered tissue and organ constructs like the heart, liver, pancreas or kidney remains a major challenge in tissue engineering. Vascularization is needed to supply oxygen and nutrients and remove waste in living tissues and organs through a network that should possess high perfusion ability and significant mechanical strength and elasticity. In this paper, we introduce a fabrication process to print vascular conduits directly, where conduits were reinforced with carbon nanotubes (CNTs) to enhance their mechanical properties and bioprintability. In vitro evaluation of printed conduits encapsulated in human coronary artery smooth muscle cells was performed to characterize the effects of CNT reinforcement on the mechanical, perfusion and biological performance of the conduits. Perfusion and permeability, cell viability, extracellular matrix formation and tissue histology were assessed and discussed, and it was concluded that CNT-reinforced vascular conduits provided a foundation for mechanically appealing constructs where CNTs could be replaced with natural protein nanofibers for further integration of these conduits in large-scale tissue fabrication. (paper)

  20. In Vitro Study of Directly Bioprinted Perfusable Vasculature Conduits.

    Science.gov (United States)

    Zhang, Yahui; Yu, Yin; Akkouch, Adil; Dababneh, Amer; Dolati, Farzaneh; Ozbolat, Ibrahim T

    2015-01-01

    The ability to create three dimensional (3D) thick tissues is still a major tissue engineering challenge. It requires the development of a suitable vascular supply for an efficient media exchange. An integrated vasculature network is particularly needed when building thick functional tissues and/or organs with high metabolic activities, such as the heart, liver and pancreas. In this work, human umbilical vein smooth muscle cells (HUVSMCs) were encapsulated in sodium alginate and printed in the form of vasculature conduits using a coaxial deposition system. Detailed investigations were performed to understand the dehydration, swelling and degradation characteristics of printed conduits. In addition, because perfusional, permeable and mechanical properties are unique characteristics of natural blood vessels, for printed conduits these properties were also explored in this work. The results show that cells encapsulated in conduits had good proliferation activities and that their viability increased during prolonged in vitro culture. Deposition of smooth muscle matrix and collagen was observed around the peripheral and luminal surface in long-term cultured cellular vascular conduit through histology studies.

  1. Pumped Storage and Potential Hydropower from Conduits

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-02-25

    Th is Congressional Report, Pumped Storage Hydropower and Potential Hydropower from Conduits, addresses the technical flexibility that existing pumped storage facilities can provide to support intermittent renewable energy generation. This study considered potential upgrades or retrofit of these facilities, the technical potential of existing and new pumped storage facilities to provide grid reliability benefits, and the range of conduit hydropower opportunities available in the United States.

  2. Engineering a multimodal nerve conduit for repair of injured peripheral nerve

    Science.gov (United States)

    Quigley, A. F.; Bulluss, K. J.; Kyratzis, I. L. B.; Gilmore, K.; Mysore, T.; Schirmer, K. S. U.; Kennedy, E. L.; O'Shea, M.; Truong, Y. B.; Edwards, S. L.; Peeters, G.; Herwig, P.; Razal, J. M.; Campbell, T. E.; Lowes, K. N.; Higgins, M. J.; Moulton, S. E.; Murphy, M. A.; Cook, M. J.; Clark, G. M.; Wallace, G. G.; Kapsa, R. M. I.

    2013-02-01

    Injury to nerve tissue in the peripheral nervous system (PNS) results in long-term impairment of limb function, dysaesthesia and pain, often with associated psychological effects. Whilst minor injuries can be left to regenerate without intervention and short gaps up to 2 cm can be sutured, larger or more severe injuries commonly require autogenous nerve grafts harvested from elsewhere in the body (usually sensory nerves). Functional recovery is often suboptimal and associated with loss of sensation from the tissue innervated by the harvested nerve. The challenges that persist with nerve repair have resulted in development of nerve guides or conduits from non-neural biological tissues and various polymers to improve the prognosis for the repair of damaged nerves in the PNS. This study describes the design and fabrication of a multimodal controlled pore size nerve regeneration conduit using polylactic acid (PLA) and (PLA):poly(lactic-co-glycolic) acid (PLGA) fibers within a neurotrophin-enriched alginate hydrogel. The nerve repair conduit design consists of two types of PLGA fibers selected specifically for promotion of axonal outgrowth and Schwann cell growth (75:25 for axons; 85:15 for Schwann cells). These aligned fibers are contained within the lumen of a knitted PLA sheath coated with electrospun PLA nanofibers to control pore size. The PLGA guidance fibers within the nerve repair conduit lumen are supported within an alginate hydrogel impregnated with neurotrophic factors (NT-3 or BDNF with LIF, SMDF and MGF-1) to provide neuroprotection, stimulation of axonal growth and Schwann cell migration. The conduit was used to promote repair of transected sciatic nerve in rats over a period of 4 weeks. Over this period, it was observed that over-grooming and self-mutilation (autotomy) of the limb implanted with the conduit was significantly reduced in rats implanted with the full-configuration conduit compared to rats implanted with conduits containing only an alginate

  3. Degradation properties of the electrostatic assembly PDLLA/CS/CHS nerve conduit

    Energy Technology Data Exchange (ETDEWEB)

    Xu Haixing [School of Chemical Engineering, Wuhan University of Technology, Wuhan 430070 (China); Yan Yuhua; Wan Tao; Li Shipu, E-mail: yanyuhua8@126.co [Biomedical Materials and Engineering Research Center, Wuhan University of Technology, Wuhan 430070 (China)

    2009-08-15

    A poly(d,l-lactic acid)/chondroitin sulfate/chitosan (PDLLA/CS/CHS) nerve conduit for repairing nerve defects was prepared by electrostatic assembly and the thermally induced phase separation technique. The hydrophilic characteristics of the PDLLA/CS/CHS assembly nerve conduits were improved markedly. The degradation behavior of the nerve conduit with various assembly layers was evaluated by a pH change, weight loss rate and molecular weight change. The pH of the solution of the nerve conduit could be effectively adjusted by varying the layer numbers and overcoming the acidity-caused auto-acceleration of PDLLA; the nerve conduit can retain its integrity in a phosphate buffer solution after being degraded for 3 months. After such a conduit was implanted in the rat for 3 months, obvious degradation occurred, but the regenerated nerve was integrated and it grew successfully from the proximal to distal nerve stump. All these results implied that the degradation rate of the prepared conduit can adapt to the regeneration of the peripheral nerve, which might be a new derivative of PDLLA-based biodegradable materials for repairing nerve injuries without acidity-caused irritations and acidity-induced auto-accelerating degradation behavior as shown by PDLLA.

  4. Extreme loads seismic testing of conduit systems

    International Nuclear Information System (INIS)

    Howard, G.E.; Ibanez, P.; Harrison, S.; Shi, Z.T.

    1991-01-01

    Rigid steel conduit (thin-wall tubes with threaded connections) containing electrical cabling are a common feature in nuclear power plants. Conduit systems are in many cases classified in U.S.A. practice as Seismic Category I structures. this paper summarizes results and others aspects of a dynamic test program conducted to investigate conduit systems seismic performance under three-axis excitation for designs representative at a nuclear power plant sited near Ft. Worth, Texas (a moderate seismic zone), with a Safe Shutdown Earthquake (SSE) of 0.12 g. Test specimens where subjected to postulated seismic events, including excitation well in excess of Safe Shutdown Earthquake events typical for U.S.A. nuclear power stations. A total of 18 conduit systems of 9-meter nominal lengths were shake table mounted and subjected to a variety of tests. None of the specimens suffered loss of load capacity when subjected to a site-enveloping Safe Shutdown Earthquake (SSE). Clamp/attachment hardware failures only began to occur when earthquake input motion was scaled upward to minimum values of 2.3-4.6 times site enveloping SSE response spectra. Tensile and/or shear failure of clamp attachment bolts or studs was the failure mode in all case in which failure was induced. (author)

  5. LOAD ON BURIED PRESSURE CONDUITS WITH REFERENCE TO ...

    African Journals Online (AJOL)

    width of conduit or trench; the shearing forces on the plane between the backfill and adjacent earth; for embankment condition, the amounL of relative settlement between the backfill and adjacent earth; the rigidity of the conduit support under embankment loading. Table 3. Selected values of c'' for use in Eq. 8. Sand and.

  6. Small-sized conduits in the right ventricular outflow tract in young children: bicuspidalized homografts are a good alternative to standard conduits.

    Science.gov (United States)

    François, Katrien; De Groote, Katya; Vandekerckhove, Kristof; De Wilde, Hans; De Wolf, Daniel; Bové, Thierry

    2017-10-03

    Downsizing a homograft (HG) through bicuspidalization has been used for more than 2 decades to overcome the shortage of small-sized conduits for reconstruction of the right ventricular outflow tract (RVOT) in young children. Our goal was to investigate the durability of bicuspidalized HGs compared with other small HGs. A retrospective analysis of 93 conduits ≤20 mm, implanted over 23 years, was performed. The end-points were survival, structural valve degeneration and conduit replacement. The conduits comprised 40 pulmonary HGs, 12 aortic HGs, 17 bicuspidalized HGs and 24 xenografts. The median age, mean conduit diameter and z-value at implantation were 1.4 (interquartile range 0.3-3) years, 16.5 ± 2.7 mm and 2.8 ± 1.3, respectively. Valve position was heterotopic in 59 patients and orthotopic in 34 patients. At a mean follow-up period of 7.6 ± 5.9 years, the hospital survival rate was 89%. Freedom from explant at 5 and 10 years was 83 ± 5% and 52 ± 6%, respectively. Freedom from structural valve degeneration was 79 ± 5% at 5 years and 47 ± 6% at 10 years [68 ± 8% for pulmonary HG, 42 ± 16% for bicuspidalized HG, 31 ± 15% for aortic HG and 20 ± 9% for xenografts (log rank P right ventricular outflow tract conduit in young children. However, when a small pulmonary HG is unavailable, bicuspidalization offers a valid alternative, preferable to xenograft conduits, at mid-term follow-up. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  7. Twenty years of cable-in-conduit conductors: 1975-1995

    International Nuclear Information System (INIS)

    Dresner, L.

    1995-01-01

    This paper reviews our progress during the last two decades in understanding cable-in-conduit conductors. The emphasis is on the physical principles governing the behavior of cable-in-conduit conductors, and no detailed mathematics is presented. The paper is constructed as a historical narrative

  8. Short-term outcomes after incontinent conduit for gynecologic cancer: comparison of ileal, sigmoid, and transverse colon.

    Science.gov (United States)

    Tabbaa, Zaid M; Janco, Jo Marie T; Mariani, Andrea; Dowdy, Sean C; McGree, Michaela E; Weaver, Amy L; Cliby, William A

    2014-06-01

    The aim of this study is to estimate the overall rates of significant incontinent conduit-related complications and compare rates between conduit types. This was a retrospective review of 166 patients who underwent incontinent urinary diversion from April 1993 through April 2013. Patients were categorized by conduit type-ileal, sigmoid colon, and transverse colon. Significant conduit-related complications were assessed at 30 and 90days after surgery. Significant conduit-related complication was defined as any of the following: ureteral stricture, conduit leak, conduit obstruction, conduit ischemia, ureteral anastomotic leak, stent obstruction requiring intervention via interventional radiology procedure or reoperation, and renal failure. A total of 166 patients underwent formation of an incontinent urinary conduit, most commonly during exenteration for gynecologic malignancy. There were 129 ileal, 11 transverse colon, and 26 sigmoid conduits. The overall significant conduit-related complication rate within 30days was 15.1%. Complication rates for ileal, transverse and sigmoid conduits were 14.7%, 0%, and 23.1%, respectively (Fisher's exact test, p=0.24). By 90days, the Kaplan-Meier estimated rates of significant complications were 21.8% overall, and 22.3%, 0%, and 28.9%, respectively, by conduit type (log-rank test, p=0.19). The most common significant conduit-related complications were conduit or ureteral anastomotic leaks and conduit obstructions. By 1 and 2years following surgery, the Kaplan-Meier estimated overall rate of significant conduit-related complication increased to 26.5% and 30.1%, respectively. Our study suggests that there are multiple appropriate tissue sites for use in incontinent conduit formation, and surgical approach should be individualized. Most significant conduit-related complications occur within 90days after surgery. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Novel technique for airless connection of artificial heart to vascular conduits.

    Science.gov (United States)

    Karimov, Jamshid H; Gao, Shengqiang; Dessoffy, Raymond; Sunagawa, Gengo; Sinkewich, Martin; Grady, Patrick; Sale, Shiva; Moazami, Nader; Fukamachi, Kiyotaka

    2017-12-01

    Successful implantation of a total artificial heart relies on multiple standardized procedures, primarily the resection of the native heart, and exacting preparation of the atrial and vascular conduits for pump implant and activation. Achieving secure pump connections to inflow/outflow conduits is critical to a successful outcome. During the connection process, however, air may be introduced into the circulation, traveling to the brain and multiple organs. Such air emboli block blood flow to these areas and are detrimental to long-term survival. A correctly managed pump-to-conduit connection prevents air from collecting in the pump and conduits. To further optimize pump-connection techniques, we have developed a novel connecting sleeve that enables airless connection of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) to the conduits. In this brief report, we describe the connecting sleeve design and our initial results from two acute in vivo implantations using a scaled-down version of the CFTAH.

  10. Generation of Complex Karstic Conduit Networks with a Hydro-chemical Model

    Science.gov (United States)

    De Rooij, R.; Graham, W. D.

    2016-12-01

    The discrete-continuum approach is very well suited to simulate flow and solute transport within karst aquifers. Using this approach, discrete one-dimensional conduits are embedded within a three-dimensional continuum representative of the porous limestone matrix. Typically, however, little is known about the geometry of the karstic conduit network. As such the discrete-continuum approach is rarely used for practical applications. It may be argued, however, that the uncertainty associated with the geometry of the network could be handled by modeling an ensemble of possible karst conduit networks within a stochastic framework. We propose to generate stochastically realistic karst conduit networks by simulating the widening of conduits as caused by the dissolution of limestone over geological relevant timescales. We illustrate that advanced numerical techniques permit to solve the non-linear and coupled hydro-chemical processes efficiently, such that relatively large and complex networks can be generated in acceptable time frames. Instead of specifying flow boundary conditions on conduit cells to recharge the network as is typically done in classical speleogenesis models, we specify an effective rainfall rate over the land surface and let model physics determine the amount of water entering the network. This is advantageous since the amount of water entering the network is extremely difficult to reconstruct, whereas the effective rainfall rate may be quantified using paleoclimatic data. Furthermore, we show that poorly known flow conditions may be constrained by requiring a realistic flow field. Using our speleogenesis model we have investigated factors that influence the geometry of simulated conduit networks. We illustrate that our model generates typical branchwork, network and anastomotic conduit systems. Flow, solute transport and water ages in karst aquifers are simulated using a few illustrative networks.

  11. A polymer foam conduit seeded with Schwann cells promotes guided peripheral nerve regeneration.

    Science.gov (United States)

    Hadlock, T; Sundback, C; Hunter, D; Cheney, M; Vacanti, J P

    2000-04-01

    Alternatives to autografts have long been sought for use in bridging neural gaps. Many entubulation materials have been studied, although with generally disappointing results in comparison with autografts. The purpose of this study was to design a more effective neural guidance conduit, to introduce Schwann cells into the conduit, and to determine regenerative capability through it in an in vivo model. A novel, fully biodegradable polymer conduit was designed and fabricated for use in peripheral nerve repair, which approximates the macro- and microarchitecture of native peripheral nerves. It comprised a series of longitudinally aligned channels, with diameters ranging from 60 to 550 microns. The lumenal surfaces promoted the adherence of Schwann cells, whose presence is known to play a key role in nerve regeneration. This unique channel architecture increased the surface area available for Schwann cell adherence up to five-fold over that available through a simple hollow conduit. The conduit was composed of a high-molecular-weight copolymer of lactic and glycolic acids (PLGA) (MW 130,000) in an 85:15 monomer ratio. A novel foam-processing technique, employing low-pressure injection molding, was used to create highly porous conduits (approximately 90% pore volume) with continuous longitudinal channels. Using this technique, conduits were constructed containing 1, 5, 16, 45, or more longitudinally aligned channels. Prior to cellular seeding of these conduits, the foams were prewet with 50% ethanol, flushed with physiologic saline, and coated with laminin solution (10 microg/mL). A Schwann cell suspension was dynamically introduced into these processed foams at a concentration of 5 X 10(5) cells/mL, using a simple bioreactor flow loop. In vivo regeneration studies were carried out in which cell-laden five-channel polymer conduits (individual channel ID 500 microm, total conduit OD 2.3 mm) were implanted across a 7-mm gap in the rat sciatic nerve (n = 4), and midgraft

  12. Reverse Saphenous Conduit Flap in 19 Dogs and 1 Cat.

    Science.gov (United States)

    Cavalcanti, Jacqueline V J; Barry, Sabrina L; Lanz, Otto I; Barnes, Katherine; Coutin, Julia V

    2018-05-14

    The purpose of this retrospective study was to report the outcomes of 19 dogs and 1 cat undergoing reverse saphenous conduit flap between 1999 and 2016. Reverse saphenous conduit flap was used to treat traumatic wounds and wounds resulting from tumor excision in the hind limb; the majority of cases had medial shearing injuries. All animals had complete flap survival. In five animals (20%), minor donor site dehiscence occurred, which did not require surgery. Other postoperative complications included signs of severe venous congestion in one dog. Reverse saphenous conduit flap is a useful technique to repair skin defects of the distal hind limb.

  13. Ash production by attrition in volcanic conduits and plumes.

    Science.gov (United States)

    Jones, T J; Russell, J K

    2017-07-17

    Tephra deposits result from explosive volcanic eruption and serve as indirect probes into fragmentation processes operating in subsurface volcanic conduits. Primary magmatic fragmentation creates a population of pyroclasts through volatile-driven decompression during conduit ascent. In this study, we explore the role that secondary fragmentation, specifically attrition, has in transforming primary pyroclasts upon transport in volcanic conduits and plumes. We utilize total grain size distributions from a suite of natural and experimentally produced tephra to show that attrition is likely to occur in all explosive volcanic eruptions. Our experimental results indicate that fine ash production and surface area generation is fast (eruption column stability, tephra dispersal, aggregation, volcanic lightening generation, and has concomitant effects on aviation safety and Earth's climate.

  14. Silk fibroin enhances peripheral nerve regeneration by improving vascularization within nerve conduits.

    Science.gov (United States)

    Wang, Chunyang; Jia, Yachao; Yang, Weichao; Zhang, Cheng; Zhang, Kuihua; Chai, Yimin

    2018-07-01

    Silk fibroin (SF)-based nerve conduits have been widely used to bridge peripheral nerve defects. Our previous study showed that nerve regeneration in a SF-blended poly (l-lactide-co-ɛ-caprolactone) [P(LLA-CL)] nerve conduit is better than that in a P(LLA-CL) conduit. However, the involved mechanisms remain unclarified. Because angiogenesis within a nerve conduit plays an important role in nerve regeneration, vascularization of SF/P(LLA-CL) and P(LLA-CL) conduits was compared both in vitro and in vivo. In the present study, we observed that SF/P(LLA-CL) nanofibers significantly promoted fibroblast proliferation, and vascular endothelial growth factor secreted by fibroblasts seeded in SF/P(LLA-CL) nanofibers was more than seven-fold higher than that in P(LLA-CL) nanofibers. Conditioned medium of fibroblasts in the SF/P(LLA-CL) group stimulated more human umbilical vein endothelial cells (HUVEC) to form capillary-like networks and promoted faster HUVEC migration. The two kinds of nerve conduits were used to bridge 10-mm-length nerve defects in rats. At 3 weeks of reparation, the blood vessel area in the SF/P(LLA-CL) group was significantly larger than that in the P(LLA-CL) group. More regenerated axons and Schwann cells were also observed in the SF/P(LLA-CL) group, which was consistent with the results of blood vessels. Collectively, our data revealed that the SF/P(LLA-CL) nerve conduit enhances peripheral nerve regeneration by improving angiogenesis within the conduit. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 2070-2077, 2018. © 2018 Wiley Periodicals, Inc.

  15. Regenerative potential of silk conduits in repair of peripheral nerve injury in adult rats.

    Science.gov (United States)

    Huang, W; Begum, R; Barber, T; Ibba, V; Tee, N C H; Hussain, M; Arastoo, M; Yang, Q; Robson, L G; Lesage, S; Gheysens, T; Skaer, Nicholas J V; Knight, D P; Priestley, J V

    2012-01-01

    Various attempts have been made to develop artificial conduits for nerve repair, but with limited success. We describe here conduits made from Bombyx mori regenerated silk protein, and containing luminal fibres of Spidrex(®), a silk-based biomaterial with properties similar to those of spider silk. Assessment in vitro demonstrated that Spidrex(®) fibres support neurite outgrowth. For evaluation in vivo, silk conduits 10 mm in length and containing 0, 100, 200 or 300 luminal Spidrex(®) fibres, were implanted to bridge an 8 mm gap in the rat sciatic nerve. At 4 weeks, conduits containing 200 luminal Spidrex(®) fibres (PN200) supported 62% and 59% as much axon growth as autologous nerve graft controls at mid-conduit and distal nerve respectively. Furthermore, Spidrex(®) conduits displayed similar Schwann cell support and macrophage response to controls. At 12 weeks, animals implanted with PN200 conduits showed similar numbers of myelinated axons (81%) to controls, similar gastrocnemius muscle innervation, and similar hindpaw stance assessed by Catwalk footprint analysis. Plantar skin innervation was 73% of that of controls. PN200 Spidrex(®) conduits were also effective at bridging longer (11 and 13 mm) gaps. Our results show that Spidrex(®) conduits promote excellent axonal regeneration and function recovery, and may have potential for clinical application. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Peripheral nerve conduits: technology update

    Directory of Open Access Journals (Sweden)

    Arslantunali D

    2014-12-01

    Full Text Available D Arslantunali,1–3,* T Dursun,1,2,* D Yucel,1,4,5 N Hasirci,1,2,6 V Hasirci,1,2,7 1BIOMATEN, Center of Excellence in Biomaterials and Tissue Engineering, Middle East Technical University (METU, Ankara, Turkey; 2Department of Biotechnology, METU, Ankara, Turkey; 3Department of Bioengineering, Gumushane University, Gumushane, Turkey; 4Faculty of Engineering, Department of Medical Engineering, Acibadem University, Istanbul, Turkey; 5School of Medicine, Department of Histology and Embryology, Acibadem University, Istanbul, Turkey; 6Department of Chemistry, Faculty of Arts and Sciences, METU, Ankara, Turkey; 7Department of Biological Sciences, Faculty of Arts and Sciences, METU, Ankara, Turkey *These authors have contributed equally to this work Abstract: Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers and designs (tubular, fibrous, and matrix type are being presented. Keywords: peripheral nerve injury, natural biomaterials, synthetic biomaterials

  17. POROSITY OF THE WALL OF A NEUROLAC (R) NERVE CONDUIT HAMPERS NERVE REGENERATION

    NARCIS (Netherlands)

    Meek, Marcel F.; Den Dunnen, Wilfred F. A.

    2009-01-01

    One way to improve nerve regeneration and bridge longer nerve gaps may be the use of semipermeable/porous conduits. With porosity less biomaterial is used for the nerve conduit. We evaluated the short-term effects of porous Neurolac (R) nerve conduits for in vivo peripheral nerve regeneration. In 10

  18. Frictional melting and stick-slip behavior in volcanic conduits

    Science.gov (United States)

    Kendrick, Jackie Evan; Lavallee, Yan; Hirose, Takehiro; di Toro, Giulio; Hornby, Adrian Jakob; Hess, Kai-Uwe; Dingwell, Donald Bruce

    2013-04-01

    Dome-building eruptions have catastrophic potential, with dome collapse leading to devastating pyroclastic flows with almost no precursory warning. During dome growth, the driving forces of the buoyant magma may be superseded by controls along conduit margins; where brittle fracture and sliding can lead to formation of lubricating cataclasite and gouge. Under extreme friction, pseudotachylyte may form at the conduit margin. Understanding the conduit margin processes is vital to understanding the continuation of an eruption and we postulate that pseudotachylyte generation could be the underlying cause of stick-slip motion and associated seismic "drumbeats", which are so commonly observed at dome-building volcanoes. This view is supported by field evidence in the form of pseudotachylytes identified in lava dome products at Soufrière Hills (Montserrat) and Mount St. Helens (USA). Both eruptions were characterised by repetitive, periodic seismicity and lava spine extrusion of highly viscous magma. High velocity rotary shear (HVR) experiments demonstrate the propensity for melting of the andesitic and dacitic material (from Soufrière Hills and Mount St. Helens respectively) at upper conduit stress conditions (HVR experiments which mimic rapid velocity fluctuations in stick-slip behavior demonstrate velocity-weakening behavior of melt, with a tendency for unstable slip. During ascent, magma may slip and undergo melting along the conduit margin. In the process the shear resistance of the slip zone is increased, acting as a viscous brake halting slip (the "stick" of stick-slip motion). Sufficient buoyancy-driven pressures from ascending magma below eventually overcome resistance to produce a rapid slip event (the "slip") along the melt-bearing slip zone, which is temporarily lubricated due to velocity-weakening. New magma below experiences the same slip event more slowly (as the magma decompresses) to produce a viscous brake and the process is repeated. This allows a

  19. Polymeric Nerve Conduits with Contact Guidance Cues Used in Nerve Repair

    Institute of Scientific and Technical Information of China (English)

    G DAI; X NIU; J YIN

    2016-01-01

    In the modern life, the nerve injury frequently happens due to mechanical, chemical or thermal accidents. In the trivial injuries, the peripheral nerves can regenerate on their own; however, in most of the cases the clinical treatments are required, where relatively large nerve injury gaps are formed. Currently, the nerve repair can be accomplished by direct suture when the injury gap is not too large;while the autologous nerve graft working as the gold standard of peripheral nerve injury treatment for nerve injuries with larger gaps. However, the direct suture is limited by heavy tension at the suture sites, and the autologous nerve graft also has the drawbacks of donor site morbidity and insufifcient donor tissue. Recently, artiifcial nerve conduits have been developed as an alternative for clinical nerve repair to overcome the limitations associated with the above treatments. In order to further improve the efifciency of nerve conduits, various guidance cues are incorporated, including physical cues, biochemical signals, as well as support cells. First, this paper reviewed the contact guidance cues applied in nerve conduits, such as lumen ifllers, multi-channels and micro-patterns on the inner surface. Then, the paper focused on the polymeric nerve conduits with micro inner grooves. The polymeric nerve conduits were fabricated using the phase inversion-based ifber spinning techniques. The smart spinneret with grooved die was designed in the spinning platform, while different spinning conditions, including flow rates, air-gap distances, and polymer concentrations, were adjusted to investigate the inlfuence of fabrication conditions on the geometry of nerve conduits. The inner groove size in the nerve conduits can be precisely controlled in our hollow ifber spinning process, which can work as the efifcient contact guidance cue for nerve regeneration.

  20. Fabrication and Optimization of Gelatin/ Nano Bioglass Conduits for Peripheral Nerve Regeneration

    Directory of Open Access Journals (Sweden)

    M. Foroutan Koudehi

    2014-07-01

    Full Text Available Introduction & Objective: Peripheral nerve injury is common in trauma patients and 4.5% of all soft-tissue injuries are accompanied by defects of peripheral nerve. Peripheral nerve injuries can lead to lifetime loss of function and permanent disfigurement. Designed conduits com-prised of natural and synthetic materials are now widely used in the construction of damaged tissues. The aim of this project was to prepare nanocomposite conduits from gelatin and bioglass for damaged peripheral nerve reconstruction. Materials & Methods: In this experimental study,compound water solution of gelatin and nano bioglass synthesized through sol gel method, was made. After preparing the solution, special mandrels were dipped in solution several times and freeze dried in order to be emptied of wa-ter via sublimation. The conduits had the following dimensions: internal diameter: 1.6 mm, outside diameter: 2.2 mm and length about 12 mm. In order to evaluate the biocompatibility of conduits we used cytotoxicity test by Chinese ovary cells and MTT assay by Miapaca-2 (pancreatic cancer cell line. Results: The prepared nano bioglass and conduits were characterized using transmission elec-tron microscopy, scanning electron microscopy, fourier transformed infrared spectroscopy and X-ray diffraction. Results of biocompatibility test showed no sign of cytotoxicity and cells were found to be attached to the pore walls offered by the conduits. Conclusion: According to the results, nano bioglass conduits could be a good candidate for peripheral nerve regeneration. (Sci J Hamadan Univ Med Sci 2014; 21 (2:152-160

  1. Midterm performance of a novel restorative pulmonary valved conduit: preclinical results

    NARCIS (Netherlands)

    Soliman, Osama I.; Miyazaki, Yosuke; Abdelghani, Mohammad; Brugmans, Marieke; Witsenburg, Maarten; Onuma, Yoshinobu; Cox, Martijn; Serruys, Patrick W.

    2017-01-01

    Aims: The Xeltis bioabsorbable pulmonary valved conduit (XPV), designed to guide functional restoration of patients' own tissue, is potentially more durable than current pulmonary bioprosthetic valves/valved conduits. The aim of this study was to assess the haemodynamic performance of the novel XPV

  2. Treatment of right ventricle to pulmonary artery conduit stenosis in infants with hypoplastic left heart syndrome.

    Science.gov (United States)

    Münsterer, Andrea; Kasnar-Samprec, Jelena; Hörer, Jürgen; Cleuziou, Julie; Eicken, Andreas; Malcic, Ivan; Lange, Rüdiger; Schreiber, Christian

    2013-09-01

    To determine the incidence of right ventricle-to-pulmonary artery (RV-PA) conduit stenosis after the Norwood I operation in patients with hypoplastic left heart syndrome (HLHS), and to determine whether the treatment strategy of RV-PA conduit stenosis has an influence on interstage and overall survival. Ninety-six patients had a Norwood operation with RV-PA conduit between 2002 and 2011. Details of reoperations/interventions due to conduit obstruction prior to bidirectional superior cavopulmonary anastomosis (BSCPA) were collected. Overall pre-BSCPA mortality was 17%, early mortality after Norwood, 6%. Early angiography was performed in 34 patients due to desaturation at a median of 8 days after the Norwood operation. Fifteen patients (16%) were diagnosed with RV-PA conduit stenosis that required treatment. The location of the conduit stenosis was significantly different in the patients with non-ringed (proximal) and the patients with ring-enforced conduit (distal), P = 0.004. In 6 patients, a surgical revision of the conduit was performed; 3 of them died prior to BSCPA. Another 6 patients had a stent implantation and 3 were treated with balloon dilatation followed by a BSCPA in the subsequent 2 weeks. All patients who were treated interventionally for RV-PA conduit obstruction had a successful BSCPA. Patients who received a surgical RV-PA conduit revision had a significantly higher interstage (P = 0.044) and overall mortality (P = 0.011) than those who received a stent or balloon dilatation of the stenosis followed by an early BSCPA. RV-PA conduit obstruction after Norwood I procedure in patients with HLHS can be safely and effectively treated by stent implantation, balloon dilatation and early BSCPA. Surgical revision of the RV-PA conduit can be reserved for patients in whom an interventional approach fails, and an early BSCPA is not an option.

  3. Collagen-coated polylactic-glycolic acid (PLGA) seeded with neural-differentiated human mesenchymal stem cells as a potential nerve conduit.

    Science.gov (United States)

    Sulong, Ahmad Fadzli; Hassan, Nur Hidayah; Hwei, Ng Min; Lokanathan, Yogeswaran; Naicker, Amaramalar Selvi; Abdullah, Shalimar; Yusof, Mohd Reusmaazran; Htwe, Ohnmar; Idrus, Ruszymah Bt Hj; Haflah, Nor Hazla Mohamed

    2014-01-01

    Autologous nerve grafts to bridge nerve gaps pose various drawbacks. Nerve tissue engineering to promote nerve regeneration using artificial neural conduits has emerged as a promising alternative. To develop an artificial nerve conduit using collagen-coated polylactic-glycolic acid (PLGA) and to analyse the survivability and propagating ability of the neuro-differentiated human mesenchymal stem cells in this conduit. The PLGA conduit was constructed by dip-molding method and coated with collagen by immersing the conduit in collagen bath. The ultra structure of the conduits were examined before they were seeded with neural-differentiated human mesenchymal stem cells (nMSC) and implanted sub-muscularly on nude mice thighs. The non-collagen-coated PLGA conduit seeded with nMSC and non-seeded non-collagen-coated PLGA conduit were also implanted for comparison purposes. The survivability and propagation ability of nMSC was studied by histological and immunohistochemical analysis. The collagen-coated conduits had a smooth inner wall and a highly porous outer wall. Conduits coated with collagen and seeded with nMSCs produced the most number of cells after 3 weeks. The best conduit based on the number of cells contained within it after 3 weeks was the collagen-coated PLGA conduit seeded with neuro-transdifferentiated cells. The collagen-coated PLGA conduit found to be suitable for attachment, survival and proliferation of the nMSC. Minimal cell infiltration was found in the implanted conduits where nearly all of the cells found in the cell seeded conduits are non-mouse origin and have neural cell markers, which exhibit the biocompatibility of the conduits. The collagen-coated PLGA conduit is biocompatible, non-cytotoxic and suitable for use as artificial nerve conduits.

  4. Development of a comprehensive inventory management system for underground fiber optic conduits.

    Science.gov (United States)

    2013-03-01

    Major State Departments of Transportation operate and maintain networks of thousands of miles of conduits, many : carrying fiber optic cables that are vital to State communication systems. These conduits are located alongside or : across highways and...

  5. In vivo visualization of microneedle conduits in human skin using laser scanning microscopy

    International Nuclear Information System (INIS)

    Bal, S; Kruithof, A C; Bouwstra, J; Liebl, H; Tomerius, M; Lademann, J; Meinke, M

    2010-01-01

    Solid microneedles enhance the penetration of drugs into the viable skin but little is known about the geometry of the conduits in vivo. Therefore, laser scanning microscopy was used to visualize the conduits of a microneedle system with needles at a length of 300 μm in 6 healthy subjects over a period of time. The model drug, a fluorescent dye was applied before and after piercing. Laser scanning microscopy was evaluated as being an excellent method to monitor the geometry and closure of the conduits over time. The used microneedle system was evaluated as suitable to enhance the transport of model drugs into the viable epidermis without bleeding and a short closure time of the conduits at the skin surface

  6. In vivo visualization of microneedle conduits in human skin using laser scanning microscopy

    Science.gov (United States)

    Bal, S.; Kruithof, A. C.; Liebl, H.; Tomerius, M.; Bouwstra, J.; Lademann, J.; Meinke, M.

    2010-03-01

    Solid microneedles enhance the penetration of drugs into the viable skin but little is known about the geometry of the conduits in vivo. Therefore, laser scanning microscopy was used to visualize the conduits of a microneedle system with needles at a length of 300 μm in 6 healthy subjects over a period of time. The model drug, a fluorescent dye was applied before and after piercing. Laser scanning microscopy was evaluated as being an excellent method to monitor the geometry and closure of the conduits over time. The used microneedle system was evaluated as suitable to enhance the transport of model drugs into the viable epidermis without bleeding and a short closure time of the conduits at the skin surface.

  7. Visualization of conduit-matrix conductivity differences in a karst aquifer using time-lapse electrical resistivity

    Science.gov (United States)

    Meyerhoff, Steven B.; Karaoulis, Marios; Fiebig, Florian; Maxwell, Reed M.; Revil, André; Martin, Jonathan B.; Graham, Wendy D.

    2012-12-01

    In the karstic upper Floridan aquifer, surface water flows into conduits of the groundwater system and may exchange with water in the aquifer matrix. This exchange has been hypothesized to occur based on differences in discharge at the Santa Fe River Sink-Rise system, north central Florida, but has yet to be visualized using any geophysical techniques. Using electrical resistivity tomography, we conducted a time-lapse study at two locations with mapped conduits connecting the Santa Fe River Sink to the Santa Fe River Rise to study changes of electrical conductivity during times of varying discharge over a six-week period. Our results show conductivity differences between matrix, conduit changes in resistivity occurring through time at the locations of mapped karst conduits, and changes in electrical conductivity during rainfall infiltration. These observations provide insight into time scales and matrix conduit conductivity differences, illustrating how surface water flow recharged to conduits may flow in a groundwater system in a karst aquifer.

  8. Scientific Results of Conduit Drilling in the Unzen Scientific Drilling Project (USDP

    Directory of Open Access Journals (Sweden)

    Kozo Uto

    2005-09-01

    Full Text Available Abstract Directional drilling at Unzen Volcano in Japan duringmid of 2004 penetrated the magma conduit and successfullyrecovered samples of the lava dike that is believed to havefed the 1991–1995 eruption. The dike was sampled about1.3 km below the volcano’s summit vent and is intrudedinto a broader conduit zone that is 0.5 km wide. This zoneconsists of multiple older lava dikes and pyroclastic veinsand has cooled to less than 200˚C. The lava dike sample wasunexpectedly altered, suggesting that circulation of hydrothermalfluids rapidly cools the conduit region of even veryactive volcanoes. It is likely that seismic signals monitoredprior to emergence of the lava dome reflected fracturing ofthe country rocks, caused by veining as volatiles escapedpredominantly upward, not outward, from the rising magma.Geophysical and geological investigation of cuttings andcore samples from the conduit and of bore-hole logging datacontinues.

  9. Explosive device of conduit using Ti Ni alloy

    Directory of Open Access Journals (Sweden)

    A. Yu. Kolobov

    2014-01-01

    Full Text Available Presently, materials have been developed which are capable at changing temperate to return significant inelastic deformations, exhibit rubber-like elasticity, convert heat into mechanical work, etc. The aggregate of these effects is usually called the shape memory effect.At present a great number of compounds and alloys with a shape memory effect has been known.These are alloys based on titanium nickelide (TiNi, copper-based alloys (Cu-Al, Cu-Sn, Cu-Al-Ni, Cu-Zn-Si, etc., gold and silver (Ag-Cd, Au-Ag-Cd, Au-Cd-Cu, Au-Zn-Cu, etc., manganese (Mn-Cr, Fe-Cu, Mn-Cu-Ni, Mn-Cu-Zr, Mn-Ni, etc., iron (Fe-Mn, Fe-Ni, Fe-Al, etc., and other compounds.The alloys based on titanium nickelide (nitinol are the most widely used.Alloys with shape memory effect find various applications in engineering and medicine, namely connecting devices, actuators, transformable design, multipurpose medical implants, etc.There is a task of breaking fuel conduit during separating the spacecraft from the rocket in space technology.The paper examines the procedure for design calculation of the separating device of conduit with the use of Ti-Ni alloy. This device can be used instead of the pyro-knives.The device contains two semi-rings from Ti-Ni alloy. In the place of break on the conduit an annular radius groove is made.At a temperature of martensite passage the semi-rings undergo deformation and in the strained state are set in the device. With heating to the temperature of the austenitic passage of bushing macro-deformation the energy stored by the nitinol bushing is great enough to break the conduit on the neck.The procedures of design calculation and response time of device are given.

  10. Peripheral nerve regeneration with conduits: use of vein tubes.

    Science.gov (United States)

    Sabongi, Rodrigo Guerra; Fernandes, Marcela; Dos Santos, João Baptista Gomes

    2015-04-01

    Treatment of peripheral nerve injuries remains a challenge to modern medicine due to the complexity of the neurobiological nerve regenerating process. There is a greater challenge when the transected nerve ends are not amenable to primary end-to-end tensionless neurorraphy. When facing a segmental nerve defect, great effort has been made to develop an alternative to the autologous nerve graft in order to circumvent morbidity at donor site, such as neuroma formation, scarring and permanent loss of function. Tubolization techniques have been developed to bridge nerve gaps and have been extensively studied in numerous experimental and clinical trials. The use of a conduit intends to act as a vehicle for moderation and modulation of the cellular and molecular ambience for nerve regeneration. Among several conduits, vein tubes were validated for clinical application with improving outcomes over the years. This article aims to address the investigation and treatment of segmental nerve injury and draw the current panorama on the use of vein tubes as an autogenous nerve conduit.

  11. Peripheral nerve regeneration with conduits: use of vein tubes

    Directory of Open Access Journals (Sweden)

    Rodrigo Guerra Sabongi

    2015-01-01

    Full Text Available Treatment of peripheral nerve injuries remains a challenge to modern medicine due to the complexity of the neurobiological nerve regenerating process. There is a greater challenge when the transected nerve ends are not amenable to primary end-to-end tensionless neurorraphy. When facing a segmental nerve defect, great effort has been made to develop an alternative to the autologous nerve graft in order to circumvent morbidity at donor site, such as neuroma formation, scarring and permanent loss of function. Tubolization techniques have been developed to bridge nerve gaps and have been extensively studied in numerous experimental and clinical trials. The use of a conduit intends to act as a vehicle for moderation and modulation of the cellular and molecular ambience for nerve regeneration. Among several conduits, vein tubes were validated for clinical application with improving outcomes over the years. This article aims to address the investigation and treatment of segmental nerve injury and draw the current panorama on the use of vein tubes as an autogenous nerve conduit.

  12. The grain-size distribution of pyroclasts: Primary fragmentation, conduit sorting or abrasion?

    Science.gov (United States)

    Kueppers, U.; Schauroth, J.; Taddeucci, J.

    2013-12-01

    Explosive volcanic eruptions expel a mixture of pyroclasts and lithics. Pyroclasts, fragments of the juvenile magma, record the state of the magma at fragmentation in terms of porosity and crystallinity. The grain size distribution of pyroclasts is generally considered to be a direct consequence of the conditions at magma fragmentation that is mainly driven by gas overpressure in bubbles, high shear rates, contact with external water or a combination of these factors. Stress exerted by any of these processes will lead to brittle fragmentation by overcoming the magma's relaxation timescale. As a consequence, most pyroclasts exhibit angular shapes. Upon magma fragmentation, the gas pyroclast mixture is accelerated upwards and eventually ejected from the vent. The total grain size distribution deposited is a function of fragmentation conditions and transport related sorting. Porous pyroclasts are very susceptible to abrasion by particle-particle or particle-conduit wall interaction. Accordingly, pyroclastic fall deposits with angular clasts should proof a low particle abrasion upon contact to other surfaces. In an attempt to constrain the degree of particle interaction during conduit flow, monomodal batches of washed pyroclasts have been accelerated upwards by rapid decompression and subsequently investigated for their grain size distribution. In our set-up, we used a vertical cylindrical tube without surface roughness as conduit. We varied grain size (0.125-0.25; 0.5-1; 1-2 mm), porosity (0; 10; 30 %), gas-particle ratio (10 and 40%), conduit length (10 and 28 cm) and conduit diameter (2.5 and 6 cm). All ejected particles were collected after settling at the base of a 3.3 m high tank and sieved at one sieve size below starting size (half-Φ). Grain size reduction showed a positive correlation with starting grain size, porosity and overpressure at the vent. Although milling in a volcanic conduit may take place, porous pyroclasts are very likely to be a primary product

  13. Free-boundary models of a meltwater conduit

    KAUST Repository

    Dallaston, Michael C.

    2014-08-01

    © 2014 AIP Publishing LLC. We analyse the cross-sectional evolution of an englacial meltwater conduit that contracts due to inward creep of the surrounding ice and expands due to melting. Making use of theoretical methods from free-boundary problems in Stokes flow and Hele-Shaw squeeze flow we construct an exact solution to the coupled problem of external viscous creep and internal heating, in which we adopt a Newtonian approximation for ice flow and an idealized uniform heat source in the conduit. This problem provides an interesting variant on standard free-boundary problems, coupling different internal and external problems through the kinematic condition at the interface. The boundary in the exact solution takes the form of an ellipse that may contract or expand (depending on the magnitudes of effective pressure and heating rate) around fixed focal points. Linear stability analysis reveals that without the melting this solution is unstable to perturbations in the shape. Melting can stabilize the interface unless the aspect ratio is too small; in that case, instabilities grow largest at the thin ends of the ellipse. The predictions are corroborated with numerical solutions using boundary integral techniques. Finally, a number of extensions to the idealized model are considered, showing that a contracting circular conduit is unstable to all modes of perturbation if melting occurs at a uniform rate around the boundary, or if the ice is modelled as a shear-thinning fluid.

  14. Improved axonal regeneration of transected spinal cord mediated by multichannel collagen conduits functionalized with neurotrophin-3 gene.

    Science.gov (United States)

    Yao, L; Daly, W; Newland, B; Yao, S; Wang, W; Chen, B K K; Madigan, N; Windebank, A; Pandit, A

    2013-12-01

    Functionalized biomaterial scaffolds targeted at improving axonal regeneration by enhancing guided axonal growth provide a promising approach for the repair of spinal cord injury. Collagen neural conduits provide structural guidance for neural tissue regeneration, and in this study it is shown that these conduits can also act as a reservoir for sustained gene delivery. Either a G-luciferase marker gene or a neurotrophin-3-encoding gene, complexed to a non-viral, cyclized, PEGylated transfection vector, was loaded within a multichannel collagen conduit. The complexed genes were then released in a controlled fashion using a dual release system both in vitro and in vivo. For evaluation of their biological performance, the loaded conduits were implanted into the completely transected rat thoracic spinal cord (T8-T10). Aligned axon regeneration through the channels of conduits was observed one month post-surgery. The conduits delivering neurotrophin-3 polyplexes resulted in significantly increased neurotrophin-3 levels in the surrounding tissue and a statistically higher number of regenerated axons versus the control conduits (P<0.05). This study suggests that collagen neural conduits delivering a highly effective non-viral therapeutic gene may hold promise for repair of the injured spinal cord.

  15. A novel balloon assisted two-stents telescoping technique for repositioning an embolized stent in the pulmonary conduit.

    Science.gov (United States)

    Kobayashi, Daisuke; Gowda, Srinath T; Forbes, Thomas J

    2014-08-01

    A 9-year-old male, with history of pulmonary atresia and ventricular septal defect, status post complete repair with a 16 mm pulmonary homograft in the right ventricular outflow tract (RVOT) underwent 3110 Palmaz stent placement for conduit stenosis. Following deployment the stent embolized proximally into the right ventricle (RV). We undertook the choice of repositioning the embolized stent into the conduit with a transcatheter approach. Using a second venous access, the embolized stent was carefully maneuvered into the proximal part of conduit with an inflated Tyshak balloon catheter. A second Palmaz 4010 stent was deployed in the distal conduit telescoping through the embolized stent. The Tyshak balloon catheter was kept inflated in the RV to stabilize the embolized stent in the proximal conduit until it was successfully latched up against the conduit with the deployment of the overlapping second stent. One year later, he underwent Melody valve implantation in the pre-stented conduit relieving conduit insufficiency. This novel balloon assisted two-stents telescoping technique is a feasible transcatheter option to secure an embolized stent from the RV to the RVOT. © 2014 Wiley Periodicals, Inc.

  16. Free-boundary models of a meltwater conduit

    KAUST Repository

    Dallaston, Michael C.; Hewitt, Ian J.

    2014-01-01

    © 2014 AIP Publishing LLC. We analyse the cross-sectional evolution of an englacial meltwater conduit that contracts due to inward creep of the surrounding ice and expands due to melting. Making use of theoretical methods from free-boundary problems

  17. Phase separation phenomena in branching conduits. Topical report Dec 78-Dec 81

    International Nuclear Information System (INIS)

    Saba, N.; Lahey, R.T. Jr.

    1982-03-01

    The analysis of Light Water Reactor (LWR) Loss-of-Coolant Accidents (LOCA's) requires that one be able to accurately calculate the two-phase flow splits in complex, branching conduits. The purpose of this study is to provide a general method for calculating the phase separation in a branching conduit. The degree of phase separation of a two-phase (air/water) mixture flowing through a plexiglas tee test section was measured. In addition, flow visualization, using high speed photography, was performed. The experimental design considerations, error analysis and the dependence of the observed phase separation on global parameters, such as inlet quality, mass flux and separation angle, are discussed. The pressure gradients were measured along the various conduits and the differential pressure was obtained at the tee junction by extrapolation. It was found that the degree of phase separation was quite pronounced, with the vapor phase preferentially separating into the branch. Using these data, a physically-based empirical model was developed with which to calculate the phasic distribution of a subsonic two-phase mixture in the downstream branches of a branching conduit

  18. Biocarbon urinary conduit: laboratory experience and clinical applications.

    Science.gov (United States)

    Kobashi, L I; Raible, D A

    1980-07-01

    A new urinary conduit utilizing pure vitreous carbon has been used successfully in dogs. Pure carbon appears to be inert with respect to urine and urothelium. Lack of urinary salt encrustation on the exposed surface provides a well-functioning urinary conduit for vesical drainage. Twenty-one vesicostomies were performed in dogs. Careful follow-up and histologic studies of removed specimens were done to establish the biocompatibility of pure carbon. All vesicostomies functioned well. A description of the device, protocol, and results of laboratory experimentation are outlined. The surgical procedure is explained in detail. Results encourage the clinical trial of these devices in humans. Indications include patients with neurogenic vesicla dysfunction and those with total urinary incontinence, both of which require permanent indwelling catheters.

  19. Uncovering Offshore Financial Centers: Conduits and Sinks in the Global Corporate Ownership Network.

    Science.gov (United States)

    Garcia-Bernardo, Javier; Fichtner, Jan; Takes, Frank W; Heemskerk, Eelke M

    2017-07-24

    Multinational corporations use highly complex structures of parents and subsidiaries to organize their operations and ownership. Offshore Financial Centers (OFCs) facilitate these structures through low taxation and lenient regulation, but are increasingly under scrutiny, for instance for enabling tax avoidance. Therefore, the identification of OFC jurisdictions has become a politicized and contested issue. We introduce a novel data-driven approach for identifying OFCs based on the global corporate ownership network, in which over 98 million firms (nodes) are connected through 71 million ownership relations. This granular firm-level network data uniquely allows identifying both sink-OFCs and conduit-OFCs. Sink-OFCs attract and retain foreign capital while conduit-OFCs are attractive intermediate destinations in the routing of international investments and enable the transfer of capital without taxation. We identify 24 sink-OFCs. In addition, a small set of five countries - the Netherlands, the United Kingdom, Ireland, Singapore and Switzerland - canalize the majority of corporate offshore investment as conduit-OFCs. Each conduit jurisdiction is specialized in a geographical area and there is significant specialization based on industrial sectors. Against the idea of OFCs as exotic small islands that cannot be regulated, we show that many sink and conduit-OFCs are highly developed countries.

  20. Novel drug delivering conduit for peripheral nerve regeneration

    Science.gov (United States)

    Labroo, Pratima; Shea, Jill; Edwards, Kyle; Ho, Scott; Davis, Brett; Sant, Himanshu; Goodwin, Isak; Gale, Bruce; Agarwal, Jay

    2017-12-01

    Objective. This paper describes the design of a novel drug delivery apparatus integrated with a poly lactic-co-glycolic acid (PLGA) based nerve guide conduit for controlled local delivery of nerve growth factor (NGF) and application in peripheral nerve gap injury. Approach. An NGF dosage curve was acquired to determine the minimum in vitro concentration for optimal neurite outgrowth of dorsal root ganglion (DRG) cells; PLGA based drug delivery devices were then designed and tested in vitro and in vivo across 15 mm rat sciatic nerve gap injury model. Main results. The drug delivery nerve guide was able to release NGF for 28 d at concentrations (0.1-10 ng ml-1) that were shown to enhance DRG neurite growth. Furthermore, the released NGF was bioactive and able to enhance DRG neurite growth. Following these tests, optimized NGF-releasing nerve conduits were implanted across 15 mm sciatic nerve gaps in a rat model, where they demonstrated significant myelination and muscle innervation in vivo as compared to empty nerve conduits (p  design process and provides increased versatility for releasing a variety of different growth factors. This innovative device has the potential for broad applicability and allows for easier customization to change the type of drugs and dosage of individual drugs without devising a completely new biomaterial-drug conjugate each time.

  1. Havery Mudd 2014-2015 Computer Science Conduit Clinic Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Aspesi, G [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bai, J [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Deese, R [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Shin, L [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-05-12

    Conduit, a new open-source library developed at Lawrence Livermore National Laboratories, provides a C++ application programming interface (API) to describe and access scientific data. Conduit’s primary use is for inmemory data exchange in high performance computing (HPC) applications. Our team tested and improved Conduit to make it more appealing to potential adopters in the HPC community. We extended Conduit’s capabilities by prototyping four libraries: one for parallel communication using MPI, one for I/O functionality, one for aggregating performance data, and one for data visualization.

  2. SQUG cable tray and conduit evaluation procedure

    International Nuclear Information System (INIS)

    Smith, P.D.; Eder, S.J.; Conoscente, J.P.

    1990-01-01

    Cable tray and conduit systems for electrical cables are a common feature and industrial facilities. They have an excellent performance history in past strong earthquake, even though they are rarely designed for earthquakes. Considerable data have been gathered on their performance in earthquakes and in shake table testing. The data have been used to develop a procedure for the verification of the seismic adequacy of cable tray and conduit systems in operating nuclear plants. The procedure is discussed in this paper. It will result in substantial savings, such as reduced engineering effort, fewer modifications of existing hardware, and simpler documentation, relative to alternate procedures like dynamic analysis of shake table testing. The procedure ensures safety-function in a unique manner since the methodology used to develop it (1) is based on a large body of historical data and (2) uses a relative approach of ensuring that nuclear plant systems will perform at least as well as systems that performed well in past earthquakes. (orig.)

  3. Structures and lithofacies of inferred silicic conduits in the Paraná-Etendeka LIP, southernmost Brazil

    Science.gov (United States)

    Simões, M. S.; Lima, E. F.; Sommer, C. A.; Rossetti, L. M. M.

    2018-04-01

    Extensive silicic units in the Paraná-Etendeka LIP have been long interpreted as pyroclastic density currents (rheomorphic ignimbrites) derived from the Messum Complex in Namibia. In recent literature, however, they have been characterized as effusive lava flows and domes. In this paper we describe structures and lithofacies related to postulated silicic lava feeder conduits at Mato Perso, São Marcos and Jaquirana-Cambará do Sul areas in southern Brazil. Inferred conduits are at least 15-25 m in width and the lithofacies include variably vesicular monomictic welded and non-welded breccias in the margins to poorly vesicular, banded, spherulitic and microfractured vitrophyres in the central parts. Flat-lying coherent vitrophyres and massive obsidian are considered to be the subaerial equivalents of the conduits. Large-scale, regional tectonic structures in southern Brazil include the NE-SW aligned Porto Alegre Suture, Leão and Açotea faults besides the Antas Lineament, a curved tectonic feature accompanying the bed of Antas river. South of the Antas Lineament smaller-scale, NW-SE lineaments limit the exposure areas of the inferred conduits. NE-SW and subordinate NW-SE structures within this smaller-scale lineaments are represented by the main postulated conduit outcrops and are parallel to the dominant sub-vertical banding in the widespread banded vitrophyre lithofacies. Upper lava flows display flat-lying foliation, pipe-like and spherical vesicles and have better developed microlites. Petrographic characteristics of the silicic vitrophyres indicate that crystal-poor magmas underwent distinct cooling paths for each inferred conduit area. The vitrophyre chemical composition is defined by the evolution of trachydacitic/dacitic vitrophyres with 62-65 wt% SiO2 to rhyodacite and rhyolite with 66-68 wt% SiO2. The more evolved rocks are assigned to the latest intrusive grey vitrophyre outcropping in the center of the conduits. Degassing pathways formed during

  4. Investigation of entrance length in circular and noncircular conduits by computational fluid dynamics simulation

    Directory of Open Access Journals (Sweden)

    Pimpun Tongpun

    2014-08-01

    Full Text Available This study estimated entrance length of circular and noncircular conduits, including circle, triangle, square and hexagon cross-sectional conduit, by using computational fluid dynamics (CFD. For simulation condition, the length of noncircular conduit was 10 m and the hydraulic diameter was 0.2 m. The laminar flow with Reynolds number of 500 and turbulent flow with Reynolds number of 50,000 were applied to investigate water flow in conduits. The governing equations were solved iteratively by using ANSYS FLUENT 14.0. For turbulent flow simulation, standard k-epsilon and RNG k-epsilon model were employed to simulate turbulence. The preliminary results were validated by comparison with theoretical data. At first, grid independency was evaluated to optimize the model. Norm* was employed to investigate the entrance length, which is related to velocity. The simulated results revealed that the entrance length for laminar flow was longer than turbulent flow.

  5. A biosynthetic nerve guide conduit based on silk/SWNT/fibronectin nanocomposite for peripheral nerve regeneration.

    Directory of Open Access Journals (Sweden)

    Fatemeh Mottaghitalab

    Full Text Available As a contribution to the functionality of nerve guide conduits (NGCs in nerve tissue engineering, here we report a conduit processing technique through introduction and evaluation of topographical, physical and chemical cues. Porous structure of NGCs based on freeze-dried silk/single walled carbon nanotubes (SF/SWNTs has shown a uniform chemical and physical structure with suitable electrical conductivity. Moreover, fibronectin (FN containing nanofibers within the structure of SF/SWNT conduits produced through electrospinning process have shown aligned fashion with appropriate porosity and diameter. Moreover, fibronectin remained its bioactivity and influenced the adhesion and growth of U373 cell lines. The conduits were then implanted to 10 mm left sciatic nerve defects in rats. The histological assessment has shown that nerve regeneration has taken places in proximal region of implanted nerve after 5 weeks following surgery. Furthermore, nerve conduction velocities (NCV and more myelinated axons were observed in SF/SWNT and SF/SWNT/FN groups after 5 weeks post implantation, indicating a functional recovery for the injured nerves. With immunohistochemistry, the higher S-100 expression of Schwann cells in SF/SWNT/FN conduits in comparison to other groups was confirmed. In conclusion, an oriented conduit of biocompatible SF/SWNT/FN has been fabricated with acceptable structure that is particularly applicable in nerve grafts.

  6. VLP seismicity from resonant modes of acoustic-gravity waves in a conduit-crack system filled with multiphase magma

    Science.gov (United States)

    Liang, C.; Prochnow, B. N.; OReilly, O. J.; Dunham, E. M.; Karlstrom, L.

    2016-12-01

    Oscillation of magma in volcanic conduits connected to cracks (dikes and sills) has been suggested as an explanation for very long period (VLP) seismic signals recorded at active basaltic volcanoes such as. Kilauea, Hawaii, and Erebus, Antarctica. We investigate the VLP seismicity using a linearized model for waves in and associated eigenmodes of a coupled conduit-crack system filled with multiphase magma, an extension of the Karlstrom and Dunham (2016) model for acoustic-gravity waves in volcanic conduits. We find that the long period surface displacement (as recorded on broadband seismometers) is dominated by opening/closing of the crack rather than the deformation of the conduit conduit walls. While the fundamental eigenmode is sensitive to the fluid properties and the geometry of the magma plumbing system, a closer scrutiny of various resonant modes reveals that the surface displacement is often more sensitive to higher modes. Here we present a systematic analysis of various long period acoustic-gravity wave resonant modes of a coupled conduit-crack system that the surface displacement is most sensitive to. We extend our previous work on a quasi-one-dimensional conduit model with inviscid magma to a more general axisymmetric conduit model that properly accounts for viscous boundary layers near the conduit walls, based on the numerical method developed by Prochnow et al. (submitted to Computers and Fluids, 2016). The surface displacement is dominated by either the fundamental or higher eigenmodes, depending on magma properties and the geometry of conduit and crack. An examination of the energetics of these modes reveals the complex interplay of different restoring forces (magma compressibility in the conduit, gravity, and elasticity of the crack) driving the VLP oscillations. Both nonequilibrium bubble growth and resorption and viscosity contribute to the damping of VLP signals. Our models thus provide a means to infer properties of open-vent basaltic volcanoes

  7. Biological conduits combining bone marrow mesenchymal stem cells and extracellular matrix to treat long-segment sciatic nerve defects

    Directory of Open Access Journals (Sweden)

    Yang Wang

    2015-01-01

    Full Text Available The transplantation of polylactic glycolic acid conduits combining bone marrow mesenchymal stem cells and extracellular matrix gel for the repair of sciatic nerve injury is effective in some respects, but few data comparing the biomechanical factors related to the sciatic nerve are available. In the present study, rabbit models of 10-mm sciatic nerve defects were prepared. The rabbit models were repaired with autologous nerve, a polylactic glycolic acid conduit + bone marrow mesenchymal stem cells, or a polylactic glycolic acid conduit + bone marrow mesenchymal stem cells + extracellular matrix gel. After 24 weeks, mechanical testing was performed to determine the stress relaxation and creep parameters. Following sciatic nerve injury, the magnitudes of the stress decrease and strain increase at 7,200 seconds were largest in the polylactic glycolic acid conduit + bone marrow mesenchymal stem cells + extracellular matrix gel group, followed by the polylactic glycolic acid conduit + bone marrow mesenchymal stem cells group, and then the autologous nerve group. Hematoxylin-eosin staining demonstrated that compared with the polylactic glycolic acid conduit + bone marrow mesenchymal stem cells group and the autologous nerve group, a more complete sciatic nerve regeneration was found, including good myelination, regularly arranged nerve fibers, and a completely degraded and resorbed conduit, in the polylactic glycolic acid conduit + bone marrow mesenchymal stem cells + extracellular matrix gel group. These results indicate that bridging 10-mm sciatic nerve defects with a polylactic glycolic acid conduit + bone marrow mesenchymal stem cells + extracellular matrix gel construct increases the stress relaxation under a constant strain, reducing anastomotic tension. Large elongations under a constant physiological load can limit the anastomotic opening and shift, which is beneficial for the regeneration and functional reconstruction of sciatic nerve. Better

  8. Transcatheter Pulmonary Valve Replacement for Right Ventricular Outflow Tract Conduit Dysfunction After the Ross Procedure

    DEFF Research Database (Denmark)

    Gillespie, Matthew J; McElhinney, Doff B; Kreutzer, Jacqueline

    2015-01-01

    BACKGROUND: Right ventricular outflow tract (RVOT) conduit dysfunction is a limitation of the Ross procedure. Transcatheter pulmonary valve replacement (TPVR) could alter the impact of conduit dysfunction and the risk-benefit balance for the Ross procedure. METHODS: Retrospective review of databa......BACKGROUND: Right ventricular outflow tract (RVOT) conduit dysfunction is a limitation of the Ross procedure. Transcatheter pulmonary valve replacement (TPVR) could alter the impact of conduit dysfunction and the risk-benefit balance for the Ross procedure. METHODS: Retrospective review....... Of these, 56 (84%) received a Melody valve; in 5 of the 11 patients who did not, the implant was aborted due to concern for coronary artery compression, and 1 implanted patient required emergent surgery for left coronary compression. The RVOT gradient decreased from a median 38 mm Hg to 13.5 mm Hg (p

  9. 26 CFR 1.58-2 - General rules for conduit entities; partnerships and partners.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 1 2010-04-01 2010-04-01 true General rules for conduit entities; partnerships...; partnerships and partners. (a) General rules for conduit entities. Sections 1.58-3 through 1.58-6 provide rules... example, if a trust has $100,000 of capital gains for the taxable year, all of which are distributed to A...

  10. Polyurethane/Gelatin Nanofibrils Neural Guidance Conduit Containing Platelet-Rich Plasma and Melatonin for Transplantation of Schwann Cells.

    Science.gov (United States)

    Salehi, Majid; Naseri-Nosar, Mahdi; Ebrahimi-Barough, Somayeh; Nourani, Mohammdreza; Khojasteh, Arash; Farzamfar, Saeed; Mansouri, Korosh; Ai, Jafar

    2018-04-01

    The current study aimed to enhance the efficacy of peripheral nerve regeneration using a biodegradable porous neural guidance conduit as a carrier to transplant allogeneic Schwann cells (SCs). The conduit was prepared from polyurethane (PU) and gelatin nanofibrils (GNFs) using thermally induced phase separation technique and filled with melatonin (MLT) and platelet-rich plasma (PRP). The prepared conduit had the porosity of 87.17 ± 1.89%, the contact angle of 78.17 ± 5.30° and the ultimate tensile strength and Young's modulus of 5.40 ± 0.98 MPa and 3.13 ± 0.65 GPa, respectively. The conduit lost about 14% of its weight after 60 days in distilled water. The produced conduit enhanced the proliferation of SCs demonstrated by a tetrazolium salt-based assay. For functional analysis, the conduit was seeded with 1.50 × 10 4 SCs (PU/GNFs/PRP/MLT/SCs) and implanted into a 10-mm sciatic nerve defect of Wistar rat. Three control groups were used: (1) PU/GNFs/SCs, (2) PU/GNFs/PRP/SCs, and (3) Autograft. The results of sciatic functional index, hot plate latency, compound muscle action potential amplitude and latency, weight-loss percentage of wet gastrocnemius muscle and histopathological examination using hematoxylin-eosin and Luxol fast blue staining, demonstrated that using the PU/GNFs/PRP/MLT conduit to transplant SCs to the sciatic nerve defect resulted in a higher regenerative outcome than the PU/GNFs and PU/GNFs/PRP conduits.

  11. Mechanical cleaning of oil spills in seawater using circular conduits

    Energy Technology Data Exchange (ETDEWEB)

    Shedid, S.; Abou Kassem, J.; Zekri, A. [United Arab Emirates Univ., Al Ain City (United Arab Emirates). Dept. of Chemical and Petroleum Engineering

    2005-10-15

    Treatment of the crude oil pollution in seawater has attracted global attention during the last two decades. This study was undertaken using circular conduits as a mechanical means to clean oil spills in seawater under different conditions of temperature, oil gravity, shaking frequency, conduit diameter, and initial thickness of oil layer. An experimental model was designed and built to achieve the study. It consists of shaking water bath (to represent sea waves) fitted with temperature controller and glass tubes of different inside diameters of 0.3 cm, 0.5 cm, and 0.7 cm. Three crude oils of different oil gravity of 35{sup o}API, 38{sup o}API, and 47{sup o}API were investigated under different shaking frequencies of 20, 40, and 60 stroke/minute with different tube diameters. The results proved that application of mechanical cleaning of oil spills using circular conduits is a practical technique. The cleaning of black oil spills is more efficient than one of volatile oil. Furthermore, the results indicated that the increase of shaking frequency and/or water temperature provide(s) faster cleaning of oil spills while temperature increase recovers the maximum oil. (Author)

  12. Geometry and Hydraulics of Englacial Conduits, Storglaciaren, Sweden

    Science.gov (United States)

    Fountain, A. G.; Schlichting, R.; Frodin, S.; Jacobel, R. W.

    2001-12-01

    Englacial conduits are the primary structure responsible for transporting surface water to the base of a glacier, where it supplies the subglacial hydraulic system and, in turn, affects glacier movement. Despite the well-known theoretical descriptions of englacial conduits, little direct evidence exists about their geometry and hydraulics. In July 2001, we initiated a field effort on Storglaciären, Sweden, to intersect englacial conduits by drilling into the glacier using a hot water drill. A companion project (Jacobel et al., this session) attempted to detect the englacial conduits using ground-penetrating radar. In a typical borehole, the water level remained at the surface while drilling through the impermeable ice. Once a connection was made, the water level dropped roughly 10 m and remained low despite continued water pumping. A small video camera was lowered, with attachments, to measure the geometry of the opening, and water flow speed. The water level in the hole provided a piezometric measure of the pressure. We drilled 22 holes at 3 separate locations and 17 (77%) connected englacially, the remaining 5 reached the bed without englacial connection, of which 2 drained at the bed. The geometry of the connections was highly irregular in cross-section with 1-2 cm openings, reminiscent of crevasse-like features rather than circular cross-sections as anticipated from the theoretical literature. Flow behavior was observed by tracking particle motion. The flow was complicated, in part by the inferred tangential intersection between the borehole and structure, and by the observed surging behavior. Flow speeds were low, on the order of 1 cm sec-1. Water level records from 3 different holes over several days exhibited highly correlated variations and large diurnal excursions. In contrast, records from holes drilled to the bed showed little variation. Based on these measurements, our conceptual picture of the englacial system is that of a sluggish flow system

  13. Tension layer winding of cable-in-conduit conductor

    International Nuclear Information System (INIS)

    Devernoe, A.; Ciancetta, G.; King, M.; Parizh, M.; Painter, T.; Miller, J.

    1996-01-01

    A 710 mm i.d. by 440 mm long, 6 layer Cable-in-Conduit (CIC) coil was precision tension layer wound with Incoloy 908 jacketed conductor to model winding technology that will be used for the Nb 3 Sn outsert coils of the 45 Tesla Hybrid Magnet Project at the US National High Magnetic Field Laboratory. This paper reports on the set up of a new winding facility with unique capabilities for insulating and winding long length CIC conductor and on special procedures which were developed to wind and support layer to layer transitions and to safely form conductor into and out of the winding. Analytical methods used to predict conduit keystoning, springback and back tensioning requirements before winding are reported in comparison to results obtained during winding and actual winding build-up dimensions on a layer by layer basis in comparison to design requirements

  14. Delineating saturated conduit patterns and dimensions in the upper Floridan aquifer through numerical groundwater flow modeling (Invited)

    Science.gov (United States)

    Kincaid, T. R.; Meyer, B. A.

    2009-12-01

    In groundwater flow modeling, aquifer permeability is typically defined through model calibration. Since the pattern and size of conduits are part of a karstic permeability framework, those parameters should be constrainable through the same process given a sufficient density of measured conditions. H2H Associates has completed a dual-permeability steady-state model of groundwater flow through the western Santa Fe River Basin, Florida from which a 380.9 km network of saturated conduits was delineated through model calibration to heads and spring discharges. Two calibration datasets were compiled describing average high-water and average low-water conditions based on heads at 145 wells and discharge from 18 springs for the high-water scenario and heads at 188 wells and discharge from 9 springs for the low-water scenario. An initial conduit network was defined by assigning paths along mapped conduits and inferring paths along potentiometric troughs between springs and swallets that had been connected by groundwater tracing. These initial conduit assignments accounted for only 13.75 and 34.1 km of the final conduit network respectively. The model was setup using FEFLOW™ where conduits were described as discrete features embedded in a porous matrix. Flow in the conduits was described by the Manning-Strickler equation where variables for conduit area and roughness were used to adjust the volume and velocity of spring flows. Matrix flow was described by Darcy’s law where hydraulic conductivity variations were limited to three geologically defined internally homogeneous zones that ranged from ~2E-6 m/s to ~4E-3 m/s. Recharge for both the high-water and low-water periods was determined through a water budget analysis where variations were restricted to nine zones defined by land-use. All remaining variations in observed head were then assumed to be due to conduits. The model was iteratively calibrated to the high-water and low-water datasets wherein the location, size

  15. 26 CFR 1.7701(l)-1 - Conduit financing arrangements.

    Science.gov (United States)

    2010-04-01

    ... determines that such recharacterization is appropriate to prevent avoidance of any tax imposed by title 26 of...) INCOME TAX (CONTINUED) INCOME TAXES General Actuarial Valuations § 1.7701(l)-1 Conduit financing...

  16. Interstage evaluation of homograft-valved right ventricle to pulmonary artery conduits for palliation of hypoplastic left heart syndrome.

    Science.gov (United States)

    Sandeep, Nefthi; Punn, Rajesh; Balasubramanian, Sowmya; Smith, Shea N; Reinhartz, Olaf; Zhang, Yulin; Wright, Gail E; Peng, Lynn F; Wise-Faberowski, Lisa; Hanley, Frank L; McElhinney, Doff B

    2018-04-01

    Palliation of hypoplastic left heart syndrome with a standard nonvalved right ventricle to pulmonary artery conduit results in an inefficient circulation in part due to diastolic regurgitation. A composite right ventricle pulmonary artery conduit with a homograft valve has a hypothetical advantage of reducing regurgitation, but may differ in the propensity for stenosis because of valve remodeling. This retrospective cohort study included 130 patients with hypoplastic left heart syndrome who underwent a modified stage 1 procedure with a right ventricle to pulmonary artery conduit from 2002 to 2015. A composite valved conduit (cryopreserved homograft valve anastomosed to a polytetrafluoroethylene tube) was placed in 100 patients (47 aortic, 32 pulmonary, 13 femoral/saphenous vein, 8 unknown), and a nonvalved conduit was used in 30 patients. Echocardiographic functional parameters were evaluated before and after stage 1 palliation and before the bidirectional Glenn procedure, and interstage interventions were assessed. On competing risk analysis, survival over time was better in the valved conduit group (P = .040), but this difference was no longer significant after adjustment for surgical era. There was no significant difference between groups in the cumulative incidence of bidirectional Glenn completion (P = .15). Patients with a valved conduit underwent more interventions for conduit obstruction in the interstage period, but this difference did not reach significance (P = .16). There were no differences between groups in echocardiographic parameters of right ventricle function at baseline or pre-Glenn. In this cohort of patients with hypoplastic left heart syndrome, inclusion of a valved right ventricle to pulmonary artery conduit was not associated with any difference in survival on adjusted analysis and did not confer an identifiable benefit on right ventricle function. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier

  17. Challenges of using electrical resistivity method to locate karst conduits-A field case in the Inner Bluegrass Region, Kentucky

    Science.gov (United States)

    Zhu, J.; Currens, J.C.; Dinger, J.S.

    2011-01-01

    Conduits serve as major pathways for groundwater flow in karst aquifers. Locating them from the surface, however, is one of the most challenging tasks in karst research. Geophysical methods are often deployed to help locate voids by mapping variations of physical properties of the subsurface. Conduits can cause significant contrasts of some physical properties that can be detected; other subsurface features such as water-bearing fractures often yield similar contrasts, which are difficult to distinguish from the effects of the conduits. This study used electrical resistivity method to search for an unmapped karst conduit that recharges Royal Spring in the Inner Bluegrass karst region, Kentucky, USA. Three types of resistivity techniques (surface 2D survey, quasi-3D survey, and time-lapse survey) were used to map and characterize resistivity anomalies. Some of the major anomalies were selected as drilling targets to verify the existence of the conduits. Drilling near an anomaly identified by an electrical resistivity profile resulted in successful penetration of a major water-filled conduit. The drilling results also suggest that, in this study area, low resistivity anomalies in general are associated with water-bearing features. However, differences in the anomaly signals between the water-filled conduit and other water-bearing features such as water-filled fracture zones were undistinguishable. The electrical resistivity method is useful in conduit detection by providing potential drilling targets. Knowledge of geology and hydrogeology about the site and professional judgment also played important roles in locating the major conduit. ?? 2011 Elsevier B.V.

  18. 3D Bioprinting of Heterogeneous Aortic Valve Conduits with Alginate/Gelatin Hydrogels

    Science.gov (United States)

    Duan, Bin; Hockaday, Laura A.; Kang, Kevin H.; Butcher, Jonathan T.

    2013-01-01

    Heart valve disease is a serious and growing public health problem for which prosthetic replacement is most commonly indicated. Current prosthetic devices are inadequate for younger adults and growing children. Tissue engineered living aortic valve conduits have potential for remodeling, regeneration, and growth, but fabricating natural anatomical complexity with cellular heterogeneity remain challenging. In the current study, we implement 3D bioprinting to fabricate living alginate/gelatin hydrogel valve conduits with anatomical architecture and direct incorporation of dual cell types in a regionally constrained manner. Encapsulated aortic root sinus smooth muscle cells (SMC) and aortic valve leaflet interstitial cells (VIC) were viable within alginate/gelatin hydrogel discs over 7 days in culture. Acellular 3D printed hydrogels exhibited reduced modulus, ultimate strength, and peak strain reducing slightly over 7-day culture, while the tensile biomechanics of cell-laden hydrogels were maintained. Aortic valve conduits were successfully bioprinted with direct encapsulation of SMC in the valve root and VIC in the leaflets. Both cell types were viable (81.4±3.4% for SMC and 83.2±4.0% for VIC) within 3D printed tissues. Encapsulated SMC expressed elevated alpha-smooth muscle actin when printed in stiff matrix, while VIC expressed elevated vimentin in soft matrix. These results demonstrate that anatomically complex, heterogeneously encapsulated aortic valve hydrogel conduits can be fabricated with 3D bioprinting. PMID:23015540

  19. Genipin-Cross-Linked Chitosan Nerve Conduits Containing TNF-α Inhibitors for Peripheral Nerve Repair.

    Science.gov (United States)

    Zhang, Li; Zhao, Weijia; Niu, Changmei; Zhou, Yujie; Shi, Haiyan; Wang, Yalin; Yang, Yumin; Tang, Xin

    2018-07-01

    Tissue engineered nerve grafts (TENGs) are considered a promising alternative to autologous nerve grafting, which is considered the "gold standard" clinical strategy for peripheral nerve repair. Here, we immobilized tumor necrosis factor-α (TNF-α) inhibitors onto a nerve conduit, which was introduced into a chitosan (CS) matrix scaffold utilizing genipin (GP) as the crosslinking agent, to fabricate CS-GP-TNF-α inhibitor nerve conduits. The in vitro release kinetics of TNF-α inhibitors from the CS-GP-TNF-α inhibitor nerve conduits were investigated using high-performance liquid chromatography. The in vivo continuous release profile of the TNF-α inhibitors released from the CS-GP-TNF-α inhibitor nerve conduits was measured using an enzyme-linked immunosorbent assay over 14 days. We found that the amount of TNF-α inhibitors released decreased with time after the bridging of the sciatic nerve defects in rats. Moreover, 4 and 12 weeks after surgery, histological analyses and functional evaluations were carried out to assess the influence of the TENG on regeneration. Immunochemistry performed 4 weeks after grafting to assess early regeneration outcomes revealed that the TENG strikingly promoted axonal outgrowth. Twelve weeks after grafting, the TENG accelerated myelin sheath formation, as well as functional restoration. In general, the regenerative outcomes following TENG more closely paralleled findings observed with autologous grafting than the use of the CS matrix scaffold. Collectively, our data indicate that the CS-GP-TNF-α inhibitor nerve conduits comprised an elaborate system for sustained release of TNF-α inhibitors in vitro, while studies in vivo demonstrated that the TENG could accelerate regenerating axonal outgrowth and functional restoration. The introduction of CS-GP-TNF-α-inhibitor nerve conduits into a scaffold may contribute to an efficient and adaptive immune microenvironment that can be used to facilitate peripheral nerve repair.

  20. 78 FR 61987 - Corbett Water District; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Science.gov (United States)

    2013-10-09

    ... District; Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and Soliciting... construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower Regulatory Efficiency Act of 2013 (HREA). The Corbett Hydroelectric...

  1. Ileal-conduit following cystectomy, single-institution revision of indications and outcome

    International Nuclear Information System (INIS)

    Abol-Enein, Hassan A.; Abdul-Muhsin, Ausama S.; Alhallaq, Yousuf M.

    2008-01-01

    Objective was to revise indications, case fatality ratio, and postoperative early and late complications of ileal conduit as a method of urinary diversion. This is a retrospective study in which 200 patients underwent an ileal conduit from August 1994 to December 2000 in Mansoura Urology and Nephrology Center, Mansoura, Egypt. Preoperative criteria of patient selection, preoperative findings and postoperative follow-up data were reviewed. In 200 patients aged 29-75 years, with a mean age of 55.84-/+ 8.91 years, the ileal conduit was chosen as a method of urinary diversion, due to one of the following patient or surgical factors; 50 (25%) cardiopulmonary co-morbidities, 27(13.5%) liver cirrhosis, 20 (10%) impaired renal function, 18 (9%) poorly controlled diabetes mellitus and 3 (1.5%) morbid obesity. Frozen section pathological examination showed carcinoma invasion of the urethra in 26 (13%) and prostate stroma in 16 (8%) male patients. Severe adhesions and difficulty cystectomy were encountered in 25 (12.5%) patients. Tumor was found at or close to the bladder neck in 13 (6.5%) female patients and 2 (1%) patients were found to have short mesentery. The mean follow up period was 90.02 -/+ 22.63 months. Fatality rate was 2%. Twenty-three (11.5%) patients had early complications, while 36 (23.7%) patients had late complications. Ileal conduit is still the best urinary diversion method in many patients who have bladder cancer with associated chronic medical disease or certain surgical factors that render other urinary diversion methods more difficult carry more postoperative morbidity and mortality or both. (author)

  2. Exploring Ultimate Water Capillary Evaporation in Nanoscale Conduits.

    Science.gov (United States)

    Li, Yinxiao; Alibakhshi, Mohammad Amin; Zhao, Yihong; Duan, Chuanhua

    2017-08-09

    Capillary evaporation in nanoscale conduits is an efficient heat/mass transfer strategy that has been widely utilized by both nature and mankind. Despite its broad impact, the ultimate transport limits of capillary evaporation in nanoscale conduits, governed by the evaporation/condensation kinetics at the liquid-vapor interface, have remained poorly understood. Here we report experimental study of the kinetic limits of water capillary evaporation in two dimensional nanochannels using a novel hybrid channel design. Our results show that the kinetic-limited evaporation fluxes break down the limits predicated by the classical Hertz-Knudsen equation by an order of magnitude, reaching values up to 37.5 mm/s with corresponding heat fluxes up to 8500 W/cm 2 . The measured evaporation flux increases with decreasing channel height and relative humidity but decreases as the channel temperature decreases. Our findings have implications for further understanding evaporation at the nanoscale and developing capillary evaporation-based technologies for both energy- and bio-related applications.

  3. 78 FR 63176 - Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and Soliciting...

    Science.gov (United States)

    2013-10-23

    ... Preliminary Determination of a Qualifying Conduit Hydropower Facility and Soliciting Comments and Motions To... of intent to construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower Regulatory Efficiency Act of 2013 (HREA). The...

  4. MR and CT imaging of pulmonary valved conduits in children and adolescents: normal appearance and complications

    Energy Technology Data Exchange (ETDEWEB)

    Tenisch, Estelle V.; Alamo, Leonor T.; Gudinchet, Francois [Lausanne University Hospital, Department of Medical Imaging, Lausanne (Switzerland); Sekarski, Nicole [Lausanne University Hospital, Department of Pediatrics, Lausanne (Switzerland); Hurni, Michel [Lausanne University Hospital, Department of Cardiovascular Surgery, Lausanne (Switzerland)

    2014-12-15

    The Contegra registered is a conduit made from the bovine jugular vein and then interposed between the right ventricle and the pulmonary artery. It is used for cardiac malformations in the reconstruction of right ventricular outflow tract. To describe both normal and pathological appearances of the Contegra registered in radiological imaging, to describe imaging of complications and to define the role of CT and MRI in postoperative follow-up. Forty-three examinations of 24 patients (17 boys and 7 girls; mean age: 10.8 years old) with Contegra registered conduits were reviewed. Anatomical description and measurements of the conduits were performed. Pathological items examined included stenosis, dilatation, plicature or twist, thrombus or vegetations, calcifications and valvular regurgitation. Findings were correlated to the echographic gradient through the conduit when available. CT and MR work-up showed Contegra registered stenosis (n = 12), dilatation (n = 9) and plicature or twist (n = 7). CT displayed thrombus or vegetations in the Contegra registered in three clinically infected patients. Calcifications of the conduit were present at CT in 12 patients and valvular regurgitation in three patients. The comparison between CT and/or MR results showed a good correlation between the echographic gradient and the presence of stenosis in the Contegra registered. CT and MR bring additional information about permeability and postoperative anatomy especially when echocardiography is inconclusive. Both techniques depict the normal appearance of the conduit, and allow comparison and precise evaluation of changes in the postoperative follow-up. (orig.)

  5. A Physicochemically Optimized and Neuroconductive Biphasic Nerve Guidance Conduit for Peripheral Nerve Repair.

    Science.gov (United States)

    Ryan, Alan J; Lackington, William A; Hibbitts, Alan J; Matheson, Austyn; Alekseeva, Tijna; Stejskalova, Anna; Roche, Phoebe; O'Brien, Fergal J

    2017-12-01

    Clinically available hollow nerve guidance conduits (NGCs) have had limited success in treating large peripheral nerve injuries. This study aims to develop a biphasic NGC combining a physicochemically optimized collagen outer conduit to bridge the transected nerve, and a neuroconductive hyaluronic acid-based luminal filler to support regeneration. The outer conduit is mechanically optimized by manipulating crosslinking and collagen density, allowing the engineering of a high wall permeability to mitigate the risk of neuroma formation, while also maintaining physiologically relevant stiffness and enzymatic degradation tuned to coincide with regeneration rates. Freeze-drying is used to seamlessly integrate the luminal filler into the conduit, creating a longitudinally aligned pore microarchitecture. The luminal stiffness is modulated to support Schwann cells, with laminin incorporation further enhancing bioactivity by improving cell attachment and metabolic activity. Additionally, this biphasic NGC is shown to support neurogenesis and gliogenesis of neural progenitor cells and axonal outgrowth from dorsal root ganglia. These findings highlight the paradigm that a successful NGC requires the concerted optimization of both a mechanical support phase capable of bridging a nerve defect and a neuroconductive phase with an architecture capable of supporting both Schwann cells and neurons in order to achieve functional regenerative outcome. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Ureteric catheterization via an ileal conduit: technique and retrieval of a JJ stent.

    Science.gov (United States)

    Wah, T M; Kellett, M J

    2004-11-01

    Retrograde ureteric catheterization of a patient with an ileal conduit is difficult, because guide wires and catheters coil in the conduit. A modified loopogram, using a Foley catheter as a fulcrum through which catheters can be advanced to the ureteric anastomosis, is described. This technique was used to remove a JJ stent, which had been inserted previously across a stricture in one ureter, the stent crossing from one kidney to the other.

  7. Continent catheterizable conduit for urinary diversion in children: Applicability and acceptability

    Directory of Open Access Journals (Sweden)

    Shailesh Solanki

    2015-01-01

    Full Text Available Background: Continent catheterizable conduit (CCC has made clean intermittent catheterization (CIC painless and easy. It is applicable in diverse clinical conditions. Nonetheless, convincing the parents for the need of conduit procedure is still difficult. Materials and Methods: A prospective study, included children who underwent CCC procedure from March 2008 to February 2013. The data were assessed for; diagnosis, type of conduit, number of preoperative counselling sessions before acceptance, role of "self-help group" in decision making, parental concern and satisfaction for the procedure. Results: Twenty-nine patients (males; 24, females; 5 underwent CCC procedure for various clinical conditions. The multiple preoperative counselling sessions and creation of "self-help groups" were helped them for decision making. The main concerns among parents were: (1 Impact of procedure on future fertility and sexual life. (2 Patency of native urethral channel. (3 Permanent urinary stoma over the abdomen. Conclusion: CCC procedures are applicable to a wide array of clinical situations with a good outcome. The acceptability of the CCC procedure improves with preoperative counselling of parent/child, initiation of preoperative per urethral CIC and creation of self-help groups.

  8. Combined use of decellularized allogeneic artery conduits with autologous transdifferentiated adipose-derived stem cells for facial nerve regeneration in rats.

    Science.gov (United States)

    Sun, Fei; Zhou, Ke; Mi, Wen-juan; Qiu, Jian-hua

    2011-11-01

    Natural biological conduits containing seed cells have been widely used as an alternative strategy for nerve gap reconstruction to replace traditional nerve autograft techniques. The purpose of this study was to investigate the effects of a decellularized allogeneic artery conduit containing autologous transdifferentiated adipose-derived stem cells (dADSCs) on an 8-mm facial nerve branch lesion in a rat model. After 8 weeks, functional evaluation of vibrissae movements and electrophysiological assessment, retrograde labeling of facial motoneurons and morphological analysis of regenerated nerves were performed to assess nerve regeneration. The transected nerves reconstructed with dADSC-seeded artery conduits achieved satisfying regenerative outcomes associated with morphological and functional improvements which approached those achieved with Schwann cell (SC)-seeded artery conduits, and superior to those achieved with artery conduits alone or ADSC-seeded artery conduits, but inferior to those achieved with nerve autografts. Besides, numerous transplanted PKH26-labeled dADSCs maintained their acquired SC-phenotype and myelin sheath-forming capacity inside decellularized artery conduits and were involved in the process of axonal regeneration and remyelination. Collectively, our combined use of decellularized allogeneic artery conduits with autologous dADSCs certainly showed beneficial effects on nerve regeneration and functional restoration, and thus represents an alternative approach for the reconstruction of peripheral facial nerve defects. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Development and Implementation of a Segment/Junction Box Level Database for the ITS Fiber Optic Conduit Network

    Science.gov (United States)

    2012-03-01

    This project initiated the development of a computerized database of ITS facilities, including conduits, junction : boxes, cameras, connections, etc. The current system consists of a database of conduit sections of various lengths. : Over the length ...

  10. The Norwood procedure: in favor of the RV-PA conduit.

    Science.gov (United States)

    Barron, David J

    2013-01-01

    Evolution of the Norwood procedure has culminated in there currently being three treatment strategies available for initial management: the 'classical' Norwood (utilizing a Blalock-Taussig shunt), the Norwood with right-ventricle to pulmonary artery (RV-PA) conduit, and the 'hybrid' Norwood procedure utilizing bilateral pulmonary artery banding and ductal stenting. Each variant has its potential advantages and disadvantages, and this paper looks to examine the evidence in favor of each strategy, with emphasis on the supportive data for the RV-PA conduit. The 'classical' procedure has the benefit of the greatest accumulated surgical experience and avoids any incision into the ventricle. However, the diastolic run-off of the Blalock-Taussig shunt can cause hemodynamic instability and unpredictable coronary steal phenomenon. The RV-PA conduit has the advantage of maintaining diastolic pressure with a more stable postoperative course, but at the cost of a ventriculotomy that may have detrimental long-term sequelae. The 'hybrid' procedure has the advantage of avoiding cardiopulmonary bypass, but does not always secure coronary blood flow and has a high inter-stage morbidity and reintervention rate. The evidence shows that each technique may have its place in future management, and that treatment algorithms could emerge that direct the choice of procedure for specific patient groups. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Parastomal hernias after radical cystectomy and ileal conduit diversion

    Directory of Open Access Journals (Sweden)

    Timothy F. Donahue

    2016-07-01

    Full Text Available Parastomal hernia, defined as an “incisional hernia related to an abdominal wall stoma”, is a frequent complication after conduit urinary diversion that can negatively impact quality of life and present a clinically significant problem for many patients. Parastomal hernia (PH rates may be as high as 65% and while many patients are asymptomatic, in some series up to 30% of patients require surgical intervention due to pain, leakage, ostomy appliance problems, urinary obstruction, and rarely bowel obstruction or strangulation. Local tissue repair, stoma relocation, and mesh repairs have been performed to correct PH, however, long-term results have been disappointing with recurrence rates of 30%–76% reported after these techniques. Due to high recurrence rates and the potential morbidity of PH repair, efforts have been made to prevent PH development at the time of the initial surgery. Randomized trials of circumstomal prophylactic mesh placement at the time of colostomy and ileostomy stoma formation have shown significant reductions in PH rates with acceptably low complication profiles. We have placed prophylactic mesh at the time of ileal conduit creation in patients at high risk for PH development and found it to be safe and effective in reducing the PH rates over the short-term. In this review, we describe the clinical and radiographic definitions of PH, the clinical impact and risk factors associated with its development, and the use of prophylactic mesh placement for patients undergoing ileal conduit urinary diversion with the intent of reducing PH rates.

  12. 78 FR 66355 - Pleasant Grove City, UT; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Science.gov (United States)

    2013-11-05

    ... City, UT; Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and... Grove City, Utah (Pleasant Grove) filed a notice of intent to construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower...

  13. 78 FR 53752 - City of Sandpoint, Idaho; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Science.gov (United States)

    2013-08-30

    ... Sandpoint, Idaho; Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and... intent to construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower Regulatory Efficiency Act of 2013 (HREA). The Little...

  14. 78 FR 61985 - City of Astoria, Oregon; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Science.gov (United States)

    2013-10-09

    ..., Oregon; Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and Soliciting... of intent to construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower Regulatory Efficiency Act of 2013 (HREA). The...

  15. Evidence for Arbovirus Dissemination Conduits from the Mosquito (Diptera: Culicidae) Midgut

    National Research Council Canada - National Science Library

    Romoser, William

    2004-01-01

    .... Experiments using Venezuelan equine encephalitis viral replicon particles, which express the green fluorescent protein gene in cells, indicate the operation of tissue conduits, possibly involving...

  16. AC losses and stability on large cable-in-conduit superconductors

    Science.gov (United States)

    Bruzzone, Pierluigi

    1998-12-01

    The cable-in-conduit superconductors are preferred for applications where the AC losses and stability are a major concern, e.g., fusion magnets and SMES. A review of coupling currents loss results for both NbTi and Nb 3Sn cable-in-conduit conductors (CICC) is presented and the AC loss relevant features are listed, with special emphasis for the role of the interstrand resistance and strand coating. The transient stability approach for CICCs is discussed and the analytical models are quoted as well as the relevant experimental database. The likely spectrum of transient disturbance in CICC is reviewed and the need to account for interstrand current sharing in the design is outlined. Eventually a practical criterion for the interstrand resistance is proposed to link the stability and AC loss design.

  17. CIBLAGE D'INFLATION ET CONDUITE DE LA POLITIQUE ...

    African Journals Online (AJOL)

    Administrateur

    de l'amendement de la loi relative à la monnaie et au crédit, l'Algérie a explicitement ... la Banque d'Algérie, très importante pour la conduite de la politique monétaire. ..... matière de contrainte budgétaire entre les secteurs public et privé. En.

  18. Design and production of stopper made of concrete foam composite used for open channel conduit cover and parking bumper

    Science.gov (United States)

    Syam, Bustami; Sebayang, Alexander; Sebayang, Septian; Muttaqin, Maraghi; Darmadi, Harry; Basuki, WS; Sabri, M.; Abda, S.

    2018-03-01

    Open channel conduit is designed and produced with the aims to reduce excess water, whether from rain, seepage, or excess irrigation water in an area. It is also included in one of the important components of urban infrastructure in tackling the problem of flooding and waterlogging. On the roadway, e.g. housing complex the open channel conduits should function the same, however conduit covers are needed. The covers should be also designed to function as parking bumper. This paper discusses the design and production of the stoppers using our newly invented materials; the stoppers are structurally tested under static, dynamic, and bump test. Response of the conduit cover are found from structural analysis using finite element software ANSYS MECHANICAL version 17.5. Two types of stoppers are introduced: flat and curvy configuration. It was obtained that both types are suitable for open channel conduit cover and parking bumper.

  19. 78 FR 56872 - City of Barre, Vermont; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Science.gov (United States)

    2013-09-16

    ..., Vermont; Notice of Preliminary Determination of a Qualifying Conduit Hydropower Facility and Soliciting... construct a qualifying conduit hydropower facility, pursuant to section 30 of the Federal Power Act, as amended by section 4 of the Hydropower Regulatory Efficiency Act of 2013 (HREA). The Nelson Street 17 kW...

  20. Sealing a conduit end

    International Nuclear Information System (INIS)

    Mentz, R.M.

    1993-01-01

    An apparatus for sealing or blocking conduits, such as the primary nozzles of a nuclear steam generator is described. It includes an annular bracket sealingly attached to the open end of the nozzle, the bracket having a plurality of threaded holes therein. Mounted atop the bracket is a generally circular nozzle dam for covering the opening. Interposed between the nozzle dam and the bracket is an extrusion-resistant seal member having a plurality of apertures therethrough for receiving each bolt. The seal member is configured to resist extrusion by having laminated layers of differing hardnesses, so that the seal member will not laterally extrude away from each bolt in a manner that enlarges the aperture surrounding each bolt as the nozzle dam is bolted to the bracket. (author)

  1. Nitric oxide permits hypoxia-induced lymphatic perfusion by controlling arterial-lymphatic conduits in zebrafish and glass catfish

    DEFF Research Database (Denmark)

    Dahl Ejby Jensen, Lasse; Cao, Renhai; Hedlund, Eva-Maria

    2009-01-01

    and lymphatic perfusion. Here we show in the adult zebrafish and glass catfish (Kryptopterus bicirrhis) that blood-lymphatic conduits directly connect arterial vessels to the lymphatic system. Under hypoxic conditions, arterial-lymphatic conduits (ALCs) became highly dilated and linearized by NO...

  2. The Use of Degradable Nerve Conduits for Human Nerve Repair: A Review of the Literature

    Directory of Open Access Journals (Sweden)

    M. F. Meek

    2005-01-01

    Full Text Available The management of peripheral nerve injury continues to be a major clinical challenge. The most widely used technique for bridging defects in peripheral nerves is the use of autologous nerve grafts. This technique, however, has some disadvantages. Many alternative experimental techniques have thus been developed, such as degradable nerve conduits. Degradable nerve guides have been extensively studied in animal experimental studies. However, the repair of human nerves by degradable nerve conduits has been limited to only a few clinical studies. In this paper, an overview of the available international published literature on degradable nerve conduits for bridging human peripheral nerve defects is presented for literature available until 2004. Also, the philosophy on the use of nerve guides and nerve grafts is given.

  3. Sciatic nerve regeneration in rats by a promising electrospun collagen/poly(ε-caprolactone nerve conduit with tailored degradation rate

    Directory of Open Access Journals (Sweden)

    Jiang Xinquan

    2011-07-01

    Full Text Available Abstract Background To cope with the limitations faced by autograft acquisitions particularly for multiple nerve injuries, artificial nerve conduit has been introduced by researchers as a substitute for autologous nerve graft for the easy specification and availability for mass production. In order to best mimic the structures and components of autologous nerve, great efforts have been made to improve the designation of nerve conduits either from materials or fabrication techniques. Electrospinning is an easy and versatile technique that has recently been used to fabricate fibrous tissue-engineered scaffolds which have great similarity to the extracellular matrix on fiber structure. Results In this study we fabricated a collagen/poly(ε-caprolactone (collagen/PCL fibrous scaffold by electrospinning and explored its application as nerve guide substrate or conduit in vitro and in vivo. Material characterizations showed this electrospun composite material which was made of submicron fibers possessed good hydrophilicity and flexibility. In vitro study indicated electrospun collagen/PCL fibrous meshes promoted Schwann cell adhesion, elongation and proliferation. In vivo test showed electrospun collagen/PCL porous nerve conduits successfully supported nerve regeneration through an 8 mm sciatic nerve gap in adult rats, achieving similar electrophysiological and muscle reinnervation results as autografts. Although regenerated nerve fibers were still in a pre-mature stage 4 months postoperatively, the implanted collagen/PCL nerve conduits facilitated more axons regenerating through the conduit lumen and gradually degraded which well matched the nerve regeneration rate. Conclusions All the results demonstrated this collagen/PCL nerve conduit with tailored degradation rate fabricated by electrospinning could be an efficient alternative to autograft for peripheral nerve regeneration research. Due to its advantage of high surface area for cell attachment, it

  4. Long-Term Regeneration and Functional Recovery of a 15 mm Critical Nerve Gap Bridged by Tremella fuciformis Polysaccharide-Immobilized Polylactide Conduits

    Directory of Open Access Journals (Sweden)

    Shan-hui Hsu

    2013-01-01

    Full Text Available Novel peripheral nerve conduits containing the negatively charged Tremella fuciformis polysaccharide (TF were prepared, and their efficacy in bridging a critical nerve gap was evaluated. The conduits were made of poly(D,L-lactide (PLA with asymmetric microporous structure. TF was immobilized on the lumen surface of the nerve conduits after open air plasma activation. The TF-modified surface was characterized by the attenuated total reflection Fourier-transformed infrared spectroscopy and the scanning electron microscopy. TF modification was found to enhance the neurotrophic gene expression of C6 glioma cells in vitro. TF-modified PLA nerve conduits were tested for their ability to bridge a 15 mm gap of rat sciatic nerve. Nerve regeneration was monitored by the magnetic resonance imaging. Results showed that TF immobilization promoted the nerve connection in 6 weeks. The functional recovery in animals receiving TF-immobilized conduits was greater than in those receiving the bare conduits during an 8-month period. The degree of functional recovery reached ~90% after 8 months in the group of TF-immobilized conduits.

  5. Analytical studies on hotspot temperature of cable-in-conduit conductors

    International Nuclear Information System (INIS)

    Yoshida, Kiyoshi; Takigami, Hiroyoshi; Kubo, Hiroatsu

    2001-01-01

    This paper describes an analytical study to review the hotspot temperature design criteria of the cable-in-conduit conductors for the ITER magnet system. The ITER magnet system uses three kinds of cable-in-conduit conductors for the Toroidal Field (TF) coils, the Central Solenoid (CS) and the Poloidal Field (PF) coils. The amount of copper in the superconducting cable has been defined by using the classical hotspot temperature design criteria that is based on the adiabatic condition. In the current design, ITER superconducting cables include a large amount of pure copper strands to satisfy the classical criteria. However, temperature and stress in the conduit and insulations after quench can be simulated with the quench simulation program and stress analysis program using the latest analysis tools. This analysis shows that the strand temperature is dominated by the conduction along strands and the heat capacity of other conductor materials and coolant. The hotspot temperature depends strongly on the delay time for quench detection. This analysis provides an estimation of delay times for quench detection. The thermal and stress analysis can provide the maximum allowable temperature after quench by determination of a failure or a functional disorder condition of the jacket material and turn insulation. In conclusion, it is found that the current density of the cable space can be increased, by reducing the extra copper strand, thereby, allowing a reduction of the coil radial build. (author)

  6. A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.

    Science.gov (United States)

    Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh

    2014-02-07

    A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.

  7. Tile drainage as karst: Conduit flow and diffuse flow in a tile-drained watershed

    Science.gov (United States)

    Schilling, K.E.; Helmers, M.

    2008-01-01

    The similarity of tiled-drained watersheds to karst drainage basins can be used to improve understanding of watershed-scale nutrient losses from subsurface tile drainage networks. In this study, short-term variations in discharge and chemistry were examined from a tile outlet collecting subsurface tile flow from a 963 ha agricultural watershed. Study objectives were to apply analytical techniques from karst springs to tile discharge to evaluate water sources and estimate the loads of agricultural pollutants discharged from the tile with conduit, intermediate and diffuse flow regimes. A two-member mixing model using nitrate, chloride and specific conductance was used to distinguish rainwater versus groundwater inputs. Results indicated that groundwater comprised 75% of the discharge for a three-day storm period and rainwater was primarily concentrated during the hydrograph peak. A contrasting pattern of solute concentrations and export loads was observed in tile flow. During base flow periods, tile flow consisted of diffuse flow from groundwater sources and contained elevated levels of nitrate, chloride and specific conductance. During storm events, suspended solids and pollutants adhered to soil surfaces (phosphorus, ammonium and organic nitrogen) were concentrated and discharged during the rapid, conduit flow portion of the hydrograph. During a three-day period, conduit flow occurred for 5.6% of the time but accounted for 16.5% of the total flow. Nitrate and chloride were delivered primarily with diffuse flow (more than 70%), whereas 80-94% of total suspended sediment, phosphorus and ammonium were exported with conduit and intermediate flow regimes. Understanding the water sources contributing to tile drainage and the manner by which pollutant discharge occurs from these systems (conduit, intermediate or diffuse flow) may be useful for designing, implementing and evaluating non-point source reduction strategies in tile-drained landscapes. ?? 2007 Elsevier B.V. All

  8. Thoracoscopic management of volvulus of the gastric conduit following minimally invasive Ivor-Lewis esophagectomy.

    Science.gov (United States)

    Linson, Jeremy; Latzko, Michael; Ahmed, Bestoun; Awad, Ziad

    2016-07-01

    We present a case of emergent thoracoscopic management of volvulus of the gastric conduit following minimally invasive Ivor-Lewis esophagectomy. The patient is a 69-year-old Caucasian male with a history of adenocarcinoma of the lower third of the esophagus. Initial presentation was dysphagia with solid foods, which progressed in severity until he was unable to swallow anything. EUS demonstrated a partially obstructing mass at 33 cm; biopsy revealed poorly differentiated adenocarcinoma, stage T3N2Mx. PET scan did not reveal any metastatic disease. Preoperative management included neo-adjuvant chemoradiation therapy (5-FU and cisplatin) and early placement of a jejunal feeding tube. Intra-operative leak test was performed as a matter of routine following completion of the esophagogastric anastomosis. A nasogastric tube was placed intra-operatively and removed on POD2 according to our standard pathway. Postoperatively, the patient progressed without difficulty to POD4, when we routinely obtain an upper GI swallow study. This demonstrated a lack of transit of contrast through the distal neo-esophagus. Follow-up endoscopy revealed volvulus of the gastric conduit with obliteration of the lumen. We immediately took the patient to the OR for thoracoscopic detorsion, which we accomplished successfully by entering the existing trochar sites and using blunt dissection.␣Upon entering the thoracic cavity, the staple line that had been oriented anteriorly was now posterior. Attachments were gently teased away from the chest wall and the conduit was detorsed and anchored to the chest wall in the correct orientation with silk suture. Intra-operative endoscopy demonstrated a patent conduit. Postoperative upper GI fluoroscopy now showed good transit of contrast. The patient continued to improve and was eventually advanced to mechanical soft diet and discharged on postoperative day 9. Early intervention is indicated in cases of volvulus of the gastric conduit following Ivor

  9. Application of near real-time radial semblance to locate the shallow magmatic conduit at Kilauea Volcano, Hawaii

    Science.gov (United States)

    Dawson, P.; Whilldin, D.; Chouet, B.

    2004-01-01

    Radial Semblance is applied to broadband seismic network data to provide source locations of Very-Long-Period (VLP) seismic energy in near real time. With an efficient algorithm and adequate network coverage, accurate source locations of VLP energy are derived to quickly locate the shallow magmatic conduit system at Kilauea Volcano, Hawaii. During a restart in magma flow following a brief pause in the current eruption, the shallow magmatic conduit is pressurized, resulting in elastic radiation from various parts of the conduit system. A steeply dipping distribution of VLP hypocenters outlines a region extending from sea level to about 550 m elevation below and just east of the Halemaumau Pit Crater. The distinct hypocenters suggest the shallow plumbing system beneath Halemaumau consists of a complex plexus of sills and dikes. An unconstrained location for a section of the conduit is also observed beneath the region between Kilauea Caldera and Kilauea Iki Crater.

  10. Numerical modeling and sensitivity analysis of seawater intrusion in a dual-permeability coastal karst aquifer with conduit networks

    Directory of Open Access Journals (Sweden)

    Z. Xu

    2018-01-01

    Full Text Available Long-distance seawater intrusion has been widely observed through the subsurface conduit system in coastal karst aquifers as a source of groundwater contaminant. In this study, seawater intrusion in a dual-permeability karst aquifer with conduit networks is studied by the two-dimensional density-dependent flow and transport SEAWAT model. Local and global sensitivity analyses are used to evaluate the impacts of boundary conditions and hydrological characteristics on modeling seawater intrusion in a karst aquifer, including hydraulic conductivity, effective porosity, specific storage, and dispersivity of the conduit network and of the porous medium. The local sensitivity analysis evaluates the parameters' sensitivities for modeling seawater intrusion, specifically in the Woodville Karst Plain (WKP. A more comprehensive interpretation of parameter sensitivities, including the nonlinear relationship between simulations and parameters, and/or parameter interactions, is addressed in the global sensitivity analysis. The conduit parameters and boundary conditions are important to the simulations in the porous medium because of the dynamical exchanges between the two systems. The sensitivity study indicates that salinity and head simulations in the karst features, such as the conduit system and submarine springs, are critical for understanding seawater intrusion in a coastal karst aquifer. The evaluation of hydraulic conductivity sensitivity in the continuum SEAWAT model may be biased since the conduit flow velocity is not accurately calculated by Darcy's equation as a function of head difference and hydraulic conductivity. In addition, dispersivity is no longer an important parameter in an advection-dominated karst aquifer with a conduit system, compared to the sensitivity results in a porous medium aquifer. In the end, the extents of seawater intrusion are quantitatively evaluated and measured under different scenarios with the variabilities of

  11. Silicic magma differentiation in ascent conduits. Experimental constraints

    Science.gov (United States)

    Rodríguez, Carmen; Castro, Antonio

    2017-02-01

    Crystallization of water-bearing silicic magmas in a dynamic thermal boundary layer is reproduced experimentally by using the intrinsic thermal gradient of piston-cylinder assemblies. The standard AGV2 andesite under water-undersaturated conditions is set to crystallize in a dynamic thermal gradient of about 35 °C/mm in 10 mm length capsules. In the hotter area of the capsule, the temperature is initially set at 1200 °C and decreases by programmed cooling at two distinct rates of 0.6 and 9.6 °C/h. Experiments are conducted in horizontally arranged assemblies in a piston cylinder apparatus to avoid any effect of gravity settling and compaction of crystals in long duration runs. The results are conclusive about the effect of water-rich fluids that are expelled out the crystal-rich zone (mush), where water saturation is reached by second boiling in the interstitial liquid. Expelled fluids migrate to the magma ahead of the solidification front contributing to a progressive enrichment in the fluxed components SiO2, K2O and H2O. The composition of water-rich fluids is modelled by mass balance using the chemical composition of glasses (quenched melt). The results are the basis for a model of granite magma differentiation in thermally-zoned conduits with application of in-situ crystallization equations. The intriguing textural and compositional features of the typical autoliths, accompanying granodiorite-tonalite batholiths, can be explained following the results of this study, by critical phenomena leading to splitting of an initially homogeneous magma into two magma systems with sharp boundaries. Magma splitting in thermal boundary layers, formed at the margins of ascent conduits, may operate for several km distances during magma transport from deep sources at the lower crust or upper mantle. Accordingly, conduits may work as chromatographic columns contributing to increase the silica content of ascending magmas and, at the same time, leave behind residual mushes that

  12. Transverse colon conduit urinary diversion in patients treated with very high dose pelvic irradiation

    International Nuclear Information System (INIS)

    Ravi, R.; Dewan, A.K.; Pandey, K.K.

    1994-01-01

    Urinary diversion may be required in patients receiving pelvic irradiation for gynaecological or genitourinary cancers either as part of a planned or salvage surgical procedure or for urological complications of irradiation. Records were reviewed for 30 such patients who underwent transverse colon conduit as a primary form of urinary diversion. Most of the conduits were constructed using refluxing ureterocolic anastomoses with stents. The results showed no operative mortality. Although the procedure was associated with a complication rate of 37% and a re-operation rate of 20%, there were no bowel or urinary anastomotic leaks. The operation could be safely performed on patients with renal failure, with 83% of such patients showing normal or improved serum creatinine levels post operatively. The advantages of transverse colon conduit urinary diversion are the use of non-irradiated bowel and ureters for diversion. It is recommended as a primary form of urinary diversion in these high risk cases. (Author)

  13. Selective reinnervation: a comparison of recovery following microsuture and conduit nerve repair.

    Science.gov (United States)

    Evans, P J; Bain, J R; Mackinnon, S E; Makino, A P; Hunter, D A

    1991-09-20

    Selective reinnervation was studied by comparing the regeneration across a conventional neurorraphy versus a conduit nerve repair. Lewis rats underwent right sciatic nerve transection followed by one of four different nerve repairs (n = 8/group). In groups I and II a conventional neurorraphy was performed and in groups III and IV the proximal and distal stumps were coapted by use of a silicone conduit with an interstump gap of 5 mm. The proximal and distal stumps in groups I and III were aligned anatomically correct and the proximal stump was rotated 180 degrees in groups II and IV (i.e. proximal peroneal nerve opposite the distal tibial nerve and the proximal tibial nerve opposite the distal peroneal nerve). By 14 weeks, there was an equivalent, but incomplete return in sciatic function index (SFI) in groups I, III, and IV as measured by walking track analysis. However, the SFI became unmeasurable by 6 weeks in all group II animals. At 14 weeks, the percent innervation of the tibialis anterior and medial gastronemius muscles by the peroneal and tibial nerves respectively was estimated by selective compound muscle action potential amplitude recordings. When fascicular alignment was reversed, there was greater tibial (P = 0.02) and lesser peroneal (P = 0.005) innervation of the gastrocnemius muscle in the conduit (group IV) versus the neurorraphy (group II) group. This suggests that the gastrocnemius muscle may be selectively reinnervated by the tibial nerve. However, there was no evidence of selective reinnervation of the tibialis anterior muscle. Despite these differences, the functional recovery in both conduit repair groups (III and IV) was equivalent to a correctly aligned microsuture repair (group I) and superior to that in the incorrectly aligned microsuture repair (group II).

  14. Pericardial tissue valves and Gore-Tex conduits as an alternative for right ventricular outflow tract replacement in children.

    Science.gov (United States)

    Allen, Bradley S; El-Zein, Chawki; Cuneo, Betina; Cava, Joseph P; Barth, Mary Jane; Ilbawi, Michel N

    2002-09-01

    There is still no perfect conduit for reconstruction of the right ventricular outflow tract (RVOT) in children. Homografts are not always available in the appropriate size, and degenerate in a few years. This study evaluates the pericardial valve with Gore-Tex conduit as an alternative for RVOT construction. From January 1, 1993, to September 30, 1999, a pericardial tissue valve was inserted in all patients undergoing RVOT reconstruction or pulmonary valve replacement (PVR) who were large enough to accommodate a tissue valve. In patients without a native main pulmonary artery, a new technique was used to construct an RV-PA conduit out of a flat sheet of Gore-Tex, as Dacron frequently leads to stenosis. Data were collected by retrospective review, follow-up echocardiograms, and assessment by a single cardiologist. There were 48 patients, 22 undergoing a PVR alone and 26 a RV-PA valved Gore-Tex conduit. Diagnosis included tetralogy of Fallot (n = 25); truncus arteriosis (n = 9); ventricular septal defect with PA (n = 5); DORV (n = 4); D-TGA with PS (n = 2); and 1 each IAA with sub AS, VSD with PI, and PS s/p Ross procedure. Patient age ranged from 3 to 33 years and 98% were reoperations. The valve sizes ranged from 19 to 33 mm and the median hospital length of stay was 4 days. There were 2 (4.2%) perioperative and 1 (2.1%) late deaths, none related to the valve or Gore-Tex conduit. At a follow-up of 15 to 86 months (mean 43 +/- 16 months), all remaining 45 patients are New York Heart Association class I, all valves are functional, and no patient has required valve or conduit replacement or revision; more importantly, echocardiogram revealed no significant valve or conduit stenosis (mean gradient 16 +/- 8 mm Hg) and no evidence of regurgitation or structural degeneration. A pericardial tissue valve and Gore-Tex conduit provides a reliable alternative for RVOT reconstruction in pediatric patients. It is readily available, molds in the limited retrosternal space, and

  15. Long distance seawater intrusion through a karst conduit network in the Woodville Karst Plain, Florida

    OpenAIRE

    Zexuan Xu; Seth Willis Bassett; Bill Hu; Scott Barrett Dyer

    2016-01-01

    Five periods of increased electrical conductivity have been found in the karst conduits supplying one of the largest first magnitude springs in Florida with water. Numerous well-developed conduit networks are distributed in the Woodville Karst Plain (WKP), Florida and connected to the Gulf of Mexico. A composite analysis of precipitation and electrical conductivity data provides strong evidence that the increases in conductivity are directly tied to seawater intrusion moving inland and travel...

  16. Lorentz force effect on mixed convection micropolar flow in a vertical conduit

    Science.gov (United States)

    Abdel-wahed, Mohamed S.

    2017-05-01

    The present work provides a simulation of control and filtration process of hydromagnetic blood flow with Hall current under the effect of heat source or sink through a vertical conduit (pipe). This work meets other engineering applications, such as nuclear reactors cooled during emergency shutdown, geophysical transport in electrically conducting and heat exchangers at low velocity conditions. The problem is modeled by a system of partial differential equations taking the effect of viscous dissipation, and these equations are simplified and solved analytically as a series solution using the Differential Transformation Method (DTM). The velocities and temperature profiles of the flow are plotted and discussed. Moreover, the conduit wall shear stress and heat flux are deduced and explained.

  17. Electromagnetic nondestructive testing at high lift-off using a magnetic image conduit

    International Nuclear Information System (INIS)

    Lee, Jin Yi; Jun, Jong Woo; Kim, Jung Min; Le, Min Hhuy

    2013-01-01

    To protect sensors from the extreme environments, such as, heat, moisture, pollution and radiation, cracks must be inspected for; this can be done by measuring the distribution of magnetic fields at high lift-off through nondestructive electro-magnetic testing. However, as the intensity of an electro-magnetic field is inversely proportional to the square of the lift-off, it becomes increasingly difficult to effective inspect a crack as the lift-off increases. In this paper, a magnetic image conduit to minimize the intensity loss of an electro-magnetic field at high lift-off is proposed, and the effectiveness of a conduit for magnetic imaging is verified by means of both theoretical and experimental approaches.

  18. Using MODFLOW with CFP to understand conduit-matrix exchange in a karst aquifer during flooding

    Science.gov (United States)

    Spellman, P.; Screaton, E.; Martin, J. B.; Gulley, J.; Brown, A.

    2011-12-01

    Karst springs may reverse flow when allogenic runoff increases river stage faster than groundwater heads and may exchange of surface water with groundwater in the surrounding aquifer matrix. Recharged flood water is rich in nutrients, metals, and organic matter and is undersaturated with respect to calcite. Understanding the physical processes controlling this exchange of water is critical to understanding metal cycling, redox chemistry and dissolution in the subsurface. Ultimately the magnitude of conduit-matrix exchange should be governed by head gradients between the conduit and the aquifer which are affected by the hydraulic conductivity of the matrix, conduit properties and antecedent groundwater heads. These parameters are interrelated and it is unknown which ones exert the greatest control over the magnitude of exchange. This study uses MODFLOW-2005 coupled with the Conduit Flow Processes (CFP) package to determine how physical properties of conduits and aquifers influence the magnitude of surface water-groundwater exchange. We use hydraulic data collected during spring reversals in a mapped underwater cave that sources Madison Blue Spring in north-central Florida to explore which factors are most important in governing exchange. The simulation focused on a major flood in 2009, when river stage increased by about 10 meters over 9 days. In a series of simulations, we varied hydraulic conductivity, conduit diameter, roughness height and tortuosity in addition to antecedent groundwater heads to estimate the relative effects of each parameter on the magnitude of conduit-matrix exchange. Each parameter was varied across plausible ranges for karst aquifers. Antecedent groundwater heads were varied using well data recorded through wet and dry seasons throughout the spring shed. We found hydraulic conductivity was the most important factor governing exchange. The volume of exchange increased by about 61% from the lowest value (1.8x10-6 m/d) to the highest value (6 m

  19. Impact of pacing modality and biventricular pacing on cardiac output and coronary conduit flow in the post-cardiotomy patient.

    LENUS (Irish Health Repository)

    Healy, David G

    2012-02-03

    We have previously demonstrated the role of univentricular pacing modalities in influencing coronary conduit flow in the immediate post-operative period in the cardiac surgery patient. We wanted to determine the mechanism of this improved coronary conduit and, in addition, to explore the possible benefits with biventricular pacing. Sixteen patients undergoing first time elective coronary artery bypass grafting who required pacing following surgery were recruited. Comparison of cardiac output and coronary conduit flow was performed between VVI and DDD pacing with a single right ventricular lead and biventricular pacing lead placement. Cardiac output was measured using arterial pulse waveform analysis while conduit flow was measured using ultrasonic transit time methodology. Cardiac output was greatest with DDD pacing using right ventricular lead placement only [DDD-univentricular 5.42 l (0.7), DDD-biventricular 5.33 l (0.8), VVI-univentricular 4.71 l (0.8), VVI-biventricular 4.68 l (0.6)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.023) and VVI-biventricular pacing (P=0.001) but there was no significant advantage to DDD-biventricular pacing (P=0.45). In relation to coronary conduit flow, DDD pacing again had the highest flow [DDD-univentricular 55 ml\\/min (24), DDD-biventricular 52 ml\\/min (25), VVI-univentricular 47 ml\\/min (23), VVI-biventricular 50 ml\\/min (26)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.006) pacing but not significantly different to VVI-biventricular pacing (P=0.109) or DDD-biventricular pacing (P=0.171). Pacing with a DDD modality offers the optimal coronary conduit flow by maximising cardiac output. Biventricular lead placement offered no significant benefit to coronary conduit flow or cardiac output.

  20. Natural Occurring Silks and Their Analogues as Materials for Nerve Conduits

    Directory of Open Access Journals (Sweden)

    Christine Radtke

    2016-10-01

    Full Text Available Spider silk and its synthetic derivatives have a light weight in combination with good strength and elasticity. Their high cytocompatibility and low immunogenicity make them well suited for biomaterial products such as nerve conduits. Silk proteins slowly degrade enzymatically in vivo, thus allowing for an initial therapeutic effect such as in nerve scaffolding to facilitate endogenous repair processes, and then are removed. Silks are biopolymers naturally produced by many species of arthropods including spiders, caterpillars and mites. The silk fibers are secreted by the labial gland of the larvae of some orders of Holometabola (insects with pupa or the spinnerets of spiders. The majority of studies using silks for biomedical applications use materials from silkworms or spiders, mostly of the genus Nephila clavipes. Silk is one of the most promising biomaterials with effects not only in nerve regeneration, but in a number of regenerative applications. The development of silks for human biomedical applications is of high scientific and clinical interest. Biomaterials in use for biomedical applications have to meet a number of requirements such as biocompatibility and elicitation of no more than a minor inflammatory response, biodegradability in a reasonable time and specific structural properties. Here we present the current status in the field of silk-based conduit development for nerve repair and discuss current advances with regard to potential clinical transfer of an implantable nerve conduit for enhancement of nerve regeneration.

  1. Water exchange and pressure transfer between conduits and matrix and their influence on hydrodynamics of two karst aquifers with sinking streams

    Science.gov (United States)

    Bailly-Comte, Vincent; Martin, Jonathan B.; Jourde, Hervé; Screaton, Elizabeth J.; Pistre, Séverin; Langston, Abigail

    2010-05-01

    SummaryKarst aquifers are heterogeneous media where conduits usually drain water from lower permeability volumes (matrix and fractures). For more than a century, various approaches have used flood recession curves, which integrate all hydrodynamic processes in a karst aquifer, to infer physical properties of the movement and storage of groundwater. These investigations typically only consider flow to the conduits and thus have lacked quantitative observations of how pressure transfer and water exchange between matrix and conduit during flooding could influence recession curves. We present analyses of simultaneous discharge and water level time series of two distinctly different karst systems, one with low porosity and permeability matrix rocks in southern France, and one with high porosity and permeability matrix rocks in north-central Florida (USA). We apply simple mathematical models of flood recession using time series representations of recharge, storage, and discharge processes in the karst aquifer. We show that karst spring hydrographs can be interpreted according to pressure transfer between two distinct components of the aquifer, conduit and matrix porosity, which induce two distinct responses at the spring. Water exchange between conduits and matrix porosity successively control the flow regime at the spring. This exchange is governed by hydraulic head differences between conduits and matrix, head gradients within conduits, and the contrast of permeability between conduits and matrix. These observations have consequences for physical interpretations of recession curves and modeling of karst spring flows, particularly for the relative magnitudes of base flow and quick flow from karst springs. Finally, these results suggest that similar analyses of recession curves can be applied to karst aquifers with distinct physical characteristics utilizing well and spring hydrograph data, but information must be known about the hydrodynamics and physical properties of

  2. Conduit dynamics in transitional rhyolitic activity recorded by tuffisite vein textures from the 2008-2009 Chaitén eruption

    Directory of Open Access Journals (Sweden)

    Elodie eSaubin

    2016-05-01

    Full Text Available The mechanisms of hazardous silicic eruptions are controlled by complex, poorly-understood conduit processes. Observations of recent Chilean rhyolite eruptions have revealed the importance of hybrid activity, involving simultaneous explosive and effusive emissions from a common vent. Such behaviour hinges upon the ability of gas to decouple from magma in the shallow conduit. Tuffisite veins are increasingly suspected to be a key facilitator of outgassing, as they repeatedly provide a transient permeable escape route for volcanic gases. Intersection of foam domains by tuffisite veins appears critical to efficient outgassing. However, knowledge is currently lacking into textural heterogeneities within shallow conduits, their relationship with tuffisite vein propagation, and the implications for fragmentation and degassing processes. Similarly, the magmatic vesiculation response to upper conduit pressure perturbations, such as those related to the slip of dense magma plugs, remains largely undefined. Here we provide a detailed characterization of an exceptionally large tuffisite vein within a rhyolitic obsidian bomb ejected during transitional explosive-effusive activity at Chaitén, Chile in May 2008. Vein textures and chemistry provide a time-integrated record of the invasion of a dense upper conduit plug by deeper fragmented magma. Quantitative textural analysis reveals diverse vesiculation histories of various juvenile clast types.Using vesicle size distributions, bubble number densities, zones of diffusive water depletion, and glass H2O concentrations, we propose a multi-step degassing/fragmentation history, spanning deep degassing to explosive bomb ejection. Rapid decompression events of ~3-4 MPa are associated with fragmentation of foam and dense magma at ~200-350 metres depth in the conduit, permitting vertical gas and pyroclast mobility over hundreds of metres. Permeable pathway occlusion in the dense conduit plug by pyroclast accumulation

  3. Comparative analysis of the pressure profilometry of vesicocutaneous continent catheterizable conduits between patients with and without rectus abdominis neosphincter (Yachia principle).

    Science.gov (United States)

    Rondon, Atila; Leslie, Bruno; Arcuri, Leonardo Javier; Ortiz, Valdemar; Macedo, Antonio

    2015-09-01

    To assess whether crossing rectus abdominis muscle strips, as proposed by Yachia, would change urinary catheterizable conduit's pressure profilometry, in static and dynamic conditions. Non-randomized selection of 20 continent patients that underwent Macedo's ileum-based reservoir, 10 including Yachia's technique (Study Group) and 10 without this mechanism of continence (Control Group). Demographics and cystometric data were assessed. Conduit's pressure profilometry was obtained by infusing saline through a multichannel catheter, at rest and during Valsalva maneuver. We assessed the pressure: (a) in the bladder; (b) in conduit's proximal segment; and (c) in conduit's distal segment, which is presumably the abdominal wall and crossed muscle strips site. Mean age at surgery was 6.1 years in the Control Group and 7.7 years in the Study Group. There was no statistically significant difference between groups regarding maximum cystometric bladder capacity and leakage point pressure. At rest, the pressure profilometry showed similar results between groups in all segments analyzed. During Valsalva maneuver, pressure profilometry showed similar results between groups in bladder and conduit's proximal segment pressure. In this condition, conduit's distal segment pressure in the Study Group (Mean = 72.9 and Peak = 128.7 cmH2 O) was significantly greater (P continence. © 2014 Wiley Periodicals, Inc.

  4. A new venous conduit utilizing the recipient portal vein branches for segment V in adult partial liver transplantation.

    Science.gov (United States)

    Moon, I S; Kim, D G; Lee, M D; Hong, S K; Park, S C; Oh, D Y; Ahn, S T; Lee, Y J

    2005-03-01

    Right anterior-medial lobe congestion due to temporary clamping of segment V and/or VIII is common in the operative theater during adult donor right lobe liver transplantation, the most common procedure in our institute. We have used an autogenous saphenous vein conduit to recipient portal vein tributaries in 15 cases, as a "Y-to-I venoplasty" since January 2004. The recipient portal vein is transected 5 mm proximal to its bifurcation and extended to both sides with partial hepatic dissection. The "Y-to-I venoplasty" is made by suture closure of the portal vein transversely to form a tube. The average length is 7.5 cm with a 1.3 cm width. One end of "Y-to-I venoplasty" conduit is anastomosed to the donor segment V branch on the back table. And the other end is anastomosed directly to the IVC via a new window or the middle hepatic vein stump in recipient. The phase distension of the conduit with respiration is noted in the operative field. A 6/15 (40%) patency rate, was observed by CT angiography at the second postoperative week. All-patient conduits showed good flow on serial examinations at the 60th postoperative day. This new venous graft, made of recipient portal vein is a good conduit for segment V decongestion in adult right lobe partial liver transplantation.

  5. Erosion of cohesive soil layers above underground conduits

    Science.gov (United States)

    Luu, Li-Hua; Philippe, Pierre; Noury, Gildas; Perrin, Jérôme; Brivois, Olivier

    2017-06-01

    Using a recently developed 2D numerical modelling that combines Discrete Element (DEM) and Lattice Boltzmann methods (LBM), we simulate the destabilisation by an hydraulic gradient of a cohesive granular soil clogging the top of an underground conduit. We aim to perform a multi-scale study that relates the grain scale behavior to the macroscopic erosion process. In particular, we study the influence of the flow conditions and the inter-particle contact forces intensity on the erosion kinetic.

  6. Documentation of a Conduit Flow Process (CFP) for MODFLOW-2005

    Science.gov (United States)

    Shoemaker, W. Barclay; Kuniansky, Eve L.; Birk, Steffen; Bauer, Sebastian; Swain, Eric D.

    2007-01-01

    This report documents the Conduit Flow Process (CFP) for the modular finite-difference ground-water flow model, MODFLOW-2005. The CFP has the ability to simulate turbulent ground-water flow conditions by: (1) coupling the traditional ground-water flow equation with formulations for a discrete network of cylindrical pipes (Mode 1), (2) inserting a high-conductivity flow layer that can switch between laminar and turbulent flow (Mode 2), or (3) simultaneously coupling a discrete pipe network while inserting a high-conductivity flow layer that can switch between laminar and turbulent flow (Mode 3). Conduit flow pipes (Mode 1) may represent dissolution or biological burrowing features in carbonate aquifers, voids in fractured rock, and (or) lava tubes in basaltic aquifers and can be fully or partially saturated under laminar or turbulent flow conditions. Preferential flow layers (Mode 2) may represent: (1) a porous media where turbulent flow is suspected to occur under the observed hydraulic gradients; (2) a single secondary porosity subsurface feature, such as a well-defined laterally extensive underground cave; or (3) a horizontal preferential flow layer consisting of many interconnected voids. In this second case, the input data are effective parameters, such as a very high hydraulic conductivity, representing multiple features. Data preparation is more complex for CFP Mode 1 (CFPM1) than for CFP Mode 2 (CFPM2). Specifically for CFPM1, conduit pipe locations, lengths, diameters, tortuosity, internal roughness, critical Reynolds numbers (NRe), and exchange conductances are required. CFPM1, however, solves the pipe network equations in a matrix that is independent of the porous media equation matrix, which may mitigate numerical instability associated with solution of dual flow components within the same matrix. CFPM2 requires less hydraulic information and knowledge about the specific location and hydraulic properties of conduits, and turbulent flow is approximated by

  7. Convection in a volcanic conduit recorded by bubbles

    Science.gov (United States)

    Carey, Rebecca J.; Manga, Michael; Degruyter, Wim; Gonnermann, Helge M.; Swanson, Donald; Houghton, Bruce F.; Orr, Tim R.; Patrick, Matthew R.

    2013-01-01

    Microtextures of juvenile pyroclasts from Kīlauea’s (Hawai‘i) early A.D. 2008 explosive activity record the velocity and depth of convection within the basaltic magma-filled conduit. We use X-ray microtomography (μXRT) to document the spatial distribution of bubbles. We find small bubbles (radii from 5 μm to 70 μm) in a halo surrounding larger millimeter-size bubbles. This suggests that dissolved water was enriched around the larger bubbles—the opposite of what is expected if bubbles grow as water diffuses into the bubble. Such volatile enrichment implies that the volatiles within the large bubbles were redissolving into the melt as they descended into the conduit by the downward motion of convecting magma within the lava lake. The thickness of the small bubble halo is ∼100–150 μm, consistent with water diffusing into the melt on time scales on the order of 103 s. Eruptions, triggered by rockfall, rapidly exposed this magma to lower pressures, and the haloes of melt with re-dissolved water became sufficiently supersaturated to cause nucleation of the population of smaller bubbles. The required supersaturation pressures are consistent with a depth of a few hundred meters and convection velocities of the order of 0.1 m s−1, similar to the circulation velocity observed on the surface of the Halema‘uma‘u lava lake.

  8. Conduit for high temperature transfer of molten semiconductor crystalline material

    Science.gov (United States)

    Fiegl, George (Inventor); Torbet, Walter (Inventor)

    1983-01-01

    A conduit for high temperature transfer of molten semiconductor crystalline material consists of a composite structure incorporating a quartz transfer tube as the innermost member, with an outer thermally insulating layer designed to serve the dual purposes of minimizing heat losses from the quartz tube and maintaining mechanical strength and rigidity of the conduit at the elevated temperatures encountered. The composite structure ensures that the molten semiconductor material only comes in contact with a material (quartz) with which it is compatible, while the outer layer structure reinforces the quartz tube, which becomes somewhat soft at molten semiconductor temperatures. To further aid in preventing cooling of the molten semiconductor, a distributed, electric resistance heater is in contact with the surface of the quartz tube over most of its length. The quartz tube has short end portions which extend through the surface of the semiconductor melt and which are lef bare of the thermal insulation. The heater is designed to provide an increased heat input per unit area in the region adjacent these end portions.

  9. Fabrication of bioactive conduits containing the fibroblast growth factor 1 and neural stem cells for peripheral nerve regeneration across a 15 mm critical gap

    International Nuclear Information System (INIS)

    Ni, Hsiao-Chiang; Tseng, Ting-Chen; Hsu, Shan-hui; Chen, Jeng-Rung; Chiu, Ing-Ming

    2013-01-01

    Nerve conduits are often used in combination with bioactive molecules and stem cells to enhance peripheral nerve regeneration. In this study, the acidic fibroblast growth factor 1 (FGF1) was immobilized onto the microporous/micropatterned poly (D, L-lactic acid) (PLA) nerve conduits after open air plasma treatment. PLA substrates grafted with chitosan in the presence of a small amount of gold nanoparticles (nano Au) showed a protective effect on the activity of the immobilized FGF1 in vitro. Different conduits were tested for their ability to bridge a 15 mm critical gap defect in a rat sciatic nerve injury model. Axon regeneration and functional recovery were evaluated by histology, walking track analysis and electrophysiology. Among different conduits, PLA conduits grafted with chitosan–nano Au and the FGF1 after plasma activation had the greatest regeneration capacity and functional recovery in the experimental animals. When the above conduit was seeded with aligned neural stem cells, the efficacy was further enhanced and it approached that of the autograft group. This work suggested that microporous/micropatterned nerve conduits containing bioactive growth factors may be successfully fabricated by micropatterning techniques, open plasma activation, and immobilization, which, combined with aligned stem cells, may synergistically contribute to the regeneration of the severely damaged peripheral nerve. (paper)

  10. Erosion of cohesive soil layers above underground conduits

    Directory of Open Access Journals (Sweden)

    Luu Li-Hua

    2017-01-01

    Full Text Available Using a recently developed 2D numerical modelling that combines Discrete Element (DEM and Lattice Boltzmann methods (LBM, we simulate the destabilisation by an hydraulic gradient of a cohesive granular soil clogging the top of an underground conduit. We aim to perform a multi-scale study that relates the grain scale behavior to the macroscopic erosion process. In particular, we study the influence of the flow conditions and the inter-particle contact forces intensity on the erosion kinetic.

  11. The Railway and the River: Conduits of Dickens’s Imaginary City

    NARCIS (Netherlands)

    Moore, B.; Murail, E.; Thornton, S.

    2017-01-01

    This chapter analyses the railway and the river as two key conduits of Dickens’ imaginary city, arguing that each simultaneously connects and fractures the modern urban world that he depicts. Focusing on Dombey and Son and Our Mutual Friend, the chapter explores how railway and river combine

  12. Three-layer microfibrous peripheral nerve guide conduit composed of elastin-laminin mimetic artificial protein and poly(L-lactic acid

    Directory of Open Access Journals (Sweden)

    Sachiro eKakinoki

    2014-07-01

    Full Text Available We developed a microfibrous poly(L-lactic acid (PLLA nerve conduit with a three-layered structure to simultaneously enhance nerve regeneration and prevent adhesion of surrounding tissue. The inner layer was composed of PLLA microfiber containing 25% elastin-laminin mimetic protein (AG73-(VPGIG30 that promotes neurite outgrowth. The thickest middle layer was constructed of pure PLLA microfibers that impart the large mechanical stremgth to the conduit. A 10% poly(ethylene glycol was added to the outer layer to prevent the adhesion with the surrounding tissue. The AG73-(VPGIG30 composisting of an elastin-like repetitive sequence (VPGIG30 and a laminin-derived sequence (RKRLQVQLSIRT: AG73 was biosynthesized using Escherichia coli. The PLLA microfibrous conduits were fabricated using an electrospinning procedure. AG73-(VPGIG30 was successfully mixed in the PLLA microfibers, and the PLLA/AG73-(VPGIG30 microfibers were stable under physiological conditions. The PLLA/AG73-(VPGIG30 microfibers enhanced adhesion and neurite outgrowth of PC12 cells. The electrospun microfibrous conduit with a three-layered structure was implanted for bridging a 2.0-cm gap in the tibial nerve of a rabbit. Two months after implantation, no adhesion of surrounding tissue was observed, and the action potential was slightly improved in the nerve conduit with the PLLA/AG73-(VPGIG30 inner layer.

  13. Three-layer microfibrous peripheral nerve guide conduit composed of elastin-laminin mimetic artificial protein and poly(L-lactic acid)

    Science.gov (United States)

    Kakinoki, Sachiro; Nakayama, Midori; Moritan, Toshiyuki; Yamaoka, Tetsuji

    2014-07-01

    We developed a microfibrous poly(L-lactic acid) (PLLA) nerve conduit with a three-layered structure to simultaneously enhance nerve regeneration and prevent adhesion of surrounding tissue. The inner layer was composed of PLLA microfiber containing 25% elastin-laminin mimetic protein (AG73-(VPGIG)30) that promotes neurite outgrowth. The thickest middle layer was constructed of pure PLLA microfibers that impart the large mechanical stremgth to the conduit. A 10% poly(ethylene glycol) was added to the outer layer to prevent the adhesion with the surrounding tissue. The AG73-(VPGIG)30 composisting of an elastin-like repetitive sequence (VPGIG)30 and a laminin-derived sequence (RKRLQVQLSIRT: AG73) was biosynthesized using Escherichia coli. The PLLA microfibrous conduits were fabricated using an electrospinning procedure. AG73-(VPGIG)30 was successfully mixed in the PLLA microfibers, and the PLLA/AG73-(VPGIG)30 microfibers were stable under physiological conditions. The PLLA/AG73-(VPGIG)30 microfibers enhanced adhesion and neurite outgrowth of PC12 cells. The electrospun microfibrous conduit with a three-layered structure was implanted for bridging a 2.0-cm gap in the tibial nerve of a rabbit. Two months after implantation, no adhesion of surrounding tissue was observed, and the action potential was slightly improved in the nerve conduit with the PLLA/AG73-(VPGIG)30 inner layer.

  14. FDG-PET identification of infected pulmonary artery conduit following tetralogy of fallot (TOF) repair

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yu Yang; Williams, Hadyn; Pucar, Darko [Dept. of Radiology, Medical College of Georgia, Augusta (United States)

    2017-03-15

    Tetralogy of Fallot (TOF) is one of the most common forms of cyanotic congenital heart disease usually managed by serial surgical repairs. The repaired prosthetic valve or conduit is susceptible to life-threatening infection. FDG-PET is an effective alternative to evaluate the source of infection when other examinations are inconclusive. We report an unusual case of an infected pulmonary artery conduit after TOF repair although the echocardiogram was negative for vegetation, which was later confirmed by surgery and pathology. The case highlights the role of FDG-PET as a problem-solving tool for potential endocarditis and cardiac device infection cases after complex cardiac surgery.

  15. FDG-PET identification of infected pulmonary artery conduit following tetralogy of fallot (TOF) repair

    International Nuclear Information System (INIS)

    Zhang, Yu Yang; Williams, Hadyn; Pucar, Darko

    2017-01-01

    Tetralogy of Fallot (TOF) is one of the most common forms of cyanotic congenital heart disease usually managed by serial surgical repairs. The repaired prosthetic valve or conduit is susceptible to life-threatening infection. FDG-PET is an effective alternative to evaluate the source of infection when other examinations are inconclusive. We report an unusual case of an infected pulmonary artery conduit after TOF repair although the echocardiogram was negative for vegetation, which was later confirmed by surgery and pathology. The case highlights the role of FDG-PET as a problem-solving tool for potential endocarditis and cardiac device infection cases after complex cardiac surgery

  16. Long distance seawater intrusion through a karst conduit network in the Woodville Karst Plain, Florida

    Science.gov (United States)

    Xu, Zexuan; Bassett, Seth Willis; Hu, Bill; Dyer, Scott Barrett

    2016-08-01

    Five periods of increased electrical conductivity have been found in the karst conduits supplying one of the largest first magnitude springs in Florida with water. Numerous well-developed conduit networks are distributed in the Woodville Karst Plain (WKP), Florida and connected to the Gulf of Mexico. A composite analysis of precipitation and electrical conductivity data provides strong evidence that the increases in conductivity are directly tied to seawater intrusion moving inland and traveling 11 miles against the prevailing regional hydraulic gradient from from Spring Creek Spring Complex (SCSC), a group of submarine springs at the Gulf Coast. A geochemical analysis of samples from the spring vent rules out anthropogenic contamination and upwelling regional recharge from the deep aquifer as sources of the rising conductivity. The interpretation is supported by the conceptual model established by prior researchers working to characterize the study area. This paper documents the first and longest case of seawater intrusion in the WKP, and also indicates significant possibility of seawater contamination through subsurface conduit networks in a coastal karst aquifer.

  17. Dual-Component Gelatinous Peptide/Reactive Oligomer Formulations as Conduit Material and Luminal Filler for Peripheral Nerve Regeneration.

    Science.gov (United States)

    Kohn-Polster, Caroline; Bhatnagar, Divya; Woloszyn, Derek J; Richtmyer, Matthew; Starke, Annett; Springwald, Alexandra H; Franz, Sandra; Schulz-Siegmund, Michaela; Kaplan, Hilton M; Kohn, Joachim; Hacker, Michael C

    2017-05-21

    Toward the next generation of nerve guidance conduits (NGCs), novel biomaterials and functionalization concepts are required to address clinical demands in peripheral nerve regeneration (PNR). As a biological polymer with bioactive motifs, gelatinous peptides are promising building blocks. In combination with an anhydride-containing oligomer, a dual-component hydrogel system (cGEL) was established. First, hollow cGEL tubes were fabricated by a continuous dosing and templating process. Conduits were characterized concerning their mechanical strength, in vitro and in vivo degradation and biocompatibility. Second, cGEL was reformulated as injectable shear thinning filler for established NGCs, here tyrosine-derived polycarbonate-based braided conduits. Thereby, the formulation contained the small molecule LM11A-31. The biofunctionalized cGEL filler was assessed regarding building block integration, mechanical properties, in vitro cytotoxicity, and growth permissive effects on human adipose tissue-derived stem cells. A positive in vitro evaluation motivated further application of the filler material in a sciatic nerve defect. Compared to the empty conduit and pristine cGEL, the functionalization performed superior, though the autologous nerve graft remains the gold standard. In conclusion, LM11A-31 functionalized cGEL filler with extracellular matrix (ECM)-like characteristics and specific biochemical cues holds great potential to support PNR.

  18. Sciatic nerve regeneration by transplantation of Schwann cells via erythropoietin controlled-releasing polylactic acid/multiwalled carbon nanotubes/gelatin nanofibrils neural guidance conduit.

    Science.gov (United States)

    Salehi, Majid; Naseri-Nosar, Mahdi; Ebrahimi-Barough, Somayeh; Nourani, Mohammdreza; Khojasteh, Arash; Hamidieh, Amir-Ali; Amani, Amir; Farzamfar, Saeed; Ai, Jafar

    2018-05-01

    The current study aimed to enhance the efficacy of peripheral nerve regeneration using an electrically conductive biodegradable porous neural guidance conduit for transplantation of allogeneic Schwann cells (SCs). The conduit was produced from polylactic acid (PLA), multiwalled carbon nanotubes (MWCNTs), and gelatin nanofibrils (GNFs) coated with the recombinant human erythropoietin-loaded chitosan nanoparticles (rhEpo-CNPs). The PLA/MWCNTs/GNFs/rhEpo-CNPs conduit had the porosity of 85.78 ± 0.70%, the contact angle of 77.65 ± 1.91° and the ultimate tensile strength and compressive modulus of 5.51 ± 0.13 MPa and 2.66 ± 0.34 MPa, respectively. The conduit showed the electrical conductivity of 0.32 S cm -1 and lost about 11% of its weight after 60 days in normal saline. The produced conduit was able to release the rhEpo for at least 2 weeks and exhibited favorable cytocompatibility towards SCs. For functional analysis, the conduit was seeded with 1.5 × 10 4 SCs and implanted into a 10 mm sciatic nerve defect of Wistar rat. After 14 weeks, the results of sciatic functional index, hot plate latency, compound muscle action potential amplitude, weight-loss percentage of wet gastrocnemius muscle and Histopathological examination using hematoxylin-eosin and Luxol fast blue staining demonstrated that the produced conduit had comparable nerve regeneration to the autograft, as the gold standard to bridge the nerve gaps. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1463-1476, 2018. © 2017 Wiley Periodicals, Inc.

  19. Magma wagging and whirling in volcanic conduits

    Science.gov (United States)

    Liao, Yang; Bercovici, David; Jellinek, Mark

    2018-02-01

    Seismic tremor characterized by 0.5-7 Hz ground oscillations commonly occur before and during eruptions at silicic volcanoes with widely ranging vent geometries and edifice structures. The ubiquitous characteristics of this tremor imply that its causes are potentially common to silicic volcanoes. Here we revisit and extend to three dimensions the magma-wagging model for tremor (Jellinek and Bercovici, 2011; Bercovici et al., 2013), wherein a stiff magma column rising in a vertical conduit oscillates against a surrounding foamy annulus of bubbly magma, giving rise to tremor. While prior studies were restricted to two-dimensional lateral oscillations, here we explore three-dimensional motion and additional modes of oscillations. In the absence of viscous damping, the magma column undergoes 'whirling' motion: the center of each horizontal section of the column traces an elliptical trajectory. In the presence of viscous effect we identify new 'coiling' and 'uncoiling' column bending shapes with relatively higher and comparable rates of dissipation to the original two-dimensional magma wagging model. We also calculate the seismic P-wave response of the crustal material around the volcanic conduit to the new whirling motions and propose seismic diagnostics for different wagging patterns using the time-lag between seismic stations. We test our model by analyzing pre-eruptive seismic data from the 2009 eruption of Redoubt Volcano. In addition to suggesting that the occurrence of elliptical whirling motion more than 1 week before the eruption, our analysis of seismic time-lags also implies that the 2009 eruption was accompanied by qualitative changes in the magma wagging behavior including fluctuations in eccentricity and a reversal in the direction of elliptical whirling motion when the eruption was immediately impending.

  20. Vulcanian explosions at Volcán de Colima, Mexico: modelling the conduit processes

    Science.gov (United States)

    Varley, N. R.; Stevenson, J.; Johnson, J.; Reyes, G.; Weber, K.; Sanderson, R.

    2006-12-01

    Activity at Volcán de Colima has increased over the past 8 years, and is possibly building towards a significant eruption. Monitoring its current activity is therefore critical, with recent expansion of the network providing new types of data which need to be understood. Recent activity has consisted of 3 effusive episodes lasting up to 22 months, separated by periods characterised by daily Vulcanian eruptions of small to moderate size; the largest producing pyroclastic flows reaching over 5 km, representing the most significant since the last Plinian event (1913). A model has been proposed to explain the mechanism of the Vulcanian explosions, derived through integrating different data including seismicity, SO2 flux and the ascent velocity and thermal emission of the eruption column. Infrasound measurements have helped to demonstrate the variability in the distribution of energy produced by the events. Swarms of low frequency seismic events were associated with the largest magnitude explosions and have been examined statistically with variations observed in the magnitude-frequency relationship of each swarm and their distribution. Seismic evidence of migration of the source has been identified, maybe explained by brittle fracturing associated with an increasing pressure differential within the conduit system. Volcán de Colima has a complex edifice structure with explosions switching between multiple vents and showing pulsing. Variation in remotely monitored fumarole temperatures has also been related to the explosive activity. It is clear that small variations of certain critical factors within the conduit system can lead to a transition between effusive and explosive activity. Frequent transitions at Volcán de Colima provide an ideal opportunity to analyse variations in the observable signals and deduce relationships with changes within the conduit that influence magma ascent and degassing, such as its volatile contents or ascent velocity. One goal of this

  1. Inactive supply wells as conduits for flow and contaminant migration: conditions of occurrence and suggestions for management

    Science.gov (United States)

    Gailey, Robert M.

    2017-11-01

    Water supply wells can act as conduits for vertical flow and contaminant migration between water-bearing strata under common hydrogeologic and well construction conditions. While recognized by some for decades, there is little published data on the magnitude of flows and extent of resulting water quality impacts. Consequently, the issue may not be acknowledged widely enough and the need for better management persists. This is especially true for unconsolidated alluvial groundwater basins that are hydrologically stressed by agricultural activities. Theoretical and practical considerations indicate that significant water volumes can migrate vertically through wells. The flow is often downward, with shallow groundwater, usually poorer in quality, migrating through conduit wells to degrade deeper water quality. Field data from locations in California, USA, are presented in combination with modeling results to illustrate both the prevalence of conditions conducive to intraborehole flow and the resulting impacts to water quality. Suggestions for management of planned wells include better enforcement of current regulations and more detailed consideration of hydrogeologic conditions during design and installation. A potentially greater management challenge is presented by the large number of existing wells. Monitoring for evidence of conduit flow and solute transport in areas of high well density is recommended to identify wells that pose greater risks to water quality. Conduit wells that are discovered may be addressed through approaches that include structural modification and changes in operations.

  2. Incorporation of cooling-induced crystallization into a 2-dimensional axisymmetric conduit heat flow model

    Science.gov (United States)

    Heptinstall, David; Bouvet de Maisonneuve, Caroline; Neuberg, Jurgen; Taisne, Benoit; Collinson, Amy

    2016-04-01

    Heat flow models can bring new insights into the thermal and rheological evolution of volcanic 3 systems. We shall investigate the thermal processes and timescales in a crystallizing, static 4 magma column, with a heat flow model of Soufriere Hills Volcano (SHV), Montserrat. The latent heat of crystallization is initially computed with MELTS, as a function of pressure and temperature for an andesitic melt (SHV groundmass starting composition). Three fractional crystallization simulations are performed; two with initial pressures of 34MPa (runs 1 & 2) and one of 25MPa (run 3). Decompression rate was varied between 0.1MPa/° C (runs 1 & 3) and 0.2MPa/° C (run 2). Natural and experimental matrix glass compositions are accurately reproduced by all MELTS runs. The cumulative latent heat released for runs 1, 2 and 3 differs by less than 9% (8.69E5 J/kg*K, 9.32E5 J/kg*K, and 9.49E5 J/kg*K respectively). The 2D axisymmetric conductive cooling simulations consider a 30m-diameter conduit that extends from the surface to a depth of 1500m (34MPa). The temporal evolution of temperature is closely tracked at depths of 10m, 750m and 1400m in the centre of the conduit, at the conduit walls, and 20m from the walls into the host rock. Following initial cooling by 7-15oC at 10m depth inside the conduit, the magma temperature rebounds through latent heat release by 32-35oC over 85-123 days to a maximum temperature of 1002-1005oC. At 10m depth, it takes 4.1-9.2 years for the magma column to cool by 108-131oC and crystallize to 75wt%, at which point it cannot be easily remobilized. It takes 11-31.5 years to reach the same crystallinity at 750-1400m depth. We find a wide range in cooling timescales, particularly at depths of 750m or greater, attributed to the initial run pressure and the dominant latent heat producing crystallizing phase, Albite-rich Plagioclase Feldspar. Run 1 is shown to cool fastest and run 3 cool the slowest, with surface emissivity having the strongest cooling

  3. Characterization and Schwann Cell Seeding of up to 15.0 cm Long Spider Silk Nerve Conduits for Reconstruction of Peripheral Nerve Defects

    Directory of Open Access Journals (Sweden)

    Tim Kornfeld

    2016-11-01

    Full Text Available Nerve reconstruction of extended nerve defect injuries still remains challenging with respect to therapeutic options. The gold standard in nerve surgery is the autologous nerve graft. Due to the limitation of adequate donor nerves, surgical alternatives are needed. Nerve grafts made out of either natural or artificial materials represent this alternative. Several biomaterials are being explored and preclinical and clinical applications are ongoing. Unfortunately, nerve conduits with successful enhancement of axonal regeneration for nerve defects measuring over 4.0 cm are sparse and no conduits are available for nerve defects extending to 10.0 cm. In this study, spider silk nerve conduits seeded with Schwann cells were investigated for in vitro regeneration on defects measuring 4.0 cm, 10.0 cm and 15.0 cm in length. Schwann cells (SCs were isolated, cultured and purified. Cell purity was determined by immunofluorescence. Nerve grafts were constructed out of spider silk from Nephila edulis and decellularized ovine vessels. Finally, spider silk implants were seeded with purified Schwann cells. Cell attachment was observed within the first hour. After 7 and 21 days of culture, immunofluorescence for viability and determination of Schwann cell proliferation and migration throughout the conduits was performed. Analyses revealed that SCs maintained viable (>95% throughout the conduits independent of construct length. SC proliferation on the spider silk was determined from day 7 to day 21 with a proliferation index of 49.42% arithmetically averaged over all conduits. This indicates that spider silk nerve conduits represent a favorable environment for SC attachment, proliferation and distribution over a distance of least 15.0 cm in vitro. Thus spider silk nerve implants are a highly adequate biomaterial for nerve reconstruction.

  4. Influence of conduit flow mechanics on magma rheology and the growth style of lava domes

    Science.gov (United States)

    Husain, Taha; Elsworth, Derek; Voight, Barry; Mattioli, Glen; Jansma, Pamela

    2018-06-01

    We develop a 2-D particle-mechanics model to explore different lava-dome growth styles. These range from endogenous lava dome growth comprising expansion of a ductile dome core to the exogenous extrusion of a degassed lava plug resulting in generation of a lava spine. We couple conduit flow dynamics with surface growth of the evolving lava dome, fuelled by an open-system magma chamber undergoing continuous replenishment. The conduit flow model accounts for the variation in rheology of ascending magma that results from degassing-induced crystallization. A period of reduced effusive flow rates promote enhanced degassing-induced crystallization. A degassed lava plug extrudes exogenously for magmas with crystal contents (ϕ) of 78 per cent, yield strength >1.62 MPa, and at flow rates of 3 m3 s-1) for magma with lower relative yield strengths (p = 3 MPa) at the conduit exit is forced out by the high discharge rate pulse (2 process, which has been observed at Mount St. Helens and other locations, largely reflects gravitational loading of dome with a viscous core, with retardation by yield strength and talus friction.

  5. A 40 kA NbTi cable in conduit conductor for the large poloidal field coils of net

    International Nuclear Information System (INIS)

    Torossian, A.; Bessette, D.; Turck, B.; Kazimierzak, B.

    1990-01-01

    The main feature of this cable in conduit design is to separate the manufacture of the full length of the steel conduit (400 m) and of the cable in order to minimize the industrial risk and consequently the cost. A circular cross section for that cable seems to be the most suitable for that purpose: - axisymmetric cabling with full transposition of strands, - cable behaviour independent of the field orientation, - less deformation of subcables, - cross section remains circular when the cable is under tension and makes the slippage of the cable in the conduit easier, - butt welding of 8 m long tubes forming the conduit becomes simpler. The square external shape allows to minimize the amount of insulating material and consequently improves the overall current density of the coil. This conductor is aimed to large poloidal field coils for NET which do not require high field and in that case NbTi seems to be the best choice with regard to reliability and cost but Nb 3 Sn could be used as well. Stainless steel ribbons are inserted between subcables in order to reduce losses induced by the rapid field changes and also to improve the mechanical behaviour of the cable

  6. NRC Information No. 90-23: Improper installation of Patel conduit seals

    International Nuclear Information System (INIS)

    Rossi, C.E.

    1992-01-01

    On November 6, 1989, the staff at the H.B. Robinson plant notified the NRC that they had discovered that some of the conduit seal grommets used to seal insulated wire conductors entering environmentally qualified instrument housings were oversized for the application. The seals are used to prevent moisture from entering safety-related electrical components following loss-of-coolant accidents. The problem was attributed to inadequate installation instructions that were used when the seals were installed in 1986 and 1987. These instructions listed the grommets by wire gauge size and gave maximum wire insulation diameters for each wire size. In accordance with these instructions, the seals were selected based on wire gauge alone. However, since the insulation thickness for a given wire gauge the correct grommet size would have been the minimum wire insulation diameter for which a particular grommet will achieve an effective seal. The selection of grommet size based only on wire gauge size resulted in the installation of some grommets that were too large to provide an effective seal. As a result, some of the seals failed pressure tests that were designed to simulate post-LOCA pressures. During the investigation of the grommet leakage problem, the Robinson staff also checked the torque on the conduit seal union nuts that are used to compress the seals. EGS Corporation recommends that the union nuts be torqued to 50 ft-lb. On approximately half of the 90 seals inspected, the union nut moved about 1/4 inch when this torque was applied. EGS Corporation reports that 1/4 inch of movement does not necessarily indicate a degraded seal but recommends that the correct torque be verified on a representative sample of installed conduit seals

  7. Pseudotachylyte formation in volcanic conduits: Montserrat vs. Mount St. Helens

    Science.gov (United States)

    Kendrick, J. E.; Lavallee, Y.; Petrakova, L.; Ferk, A.; Di Toro, G.; Hess, K.; Ferri, F.; Dingwell, D. B.

    2012-12-01

    Seismogenic fracture and faulting may result in non-equilibrium frictional melting of rock, which upon cooling and recrystallisation forms pseudotachylyte. In volcanic environments, the transition from endogenous to exogenous growth can be attributed to a shift in magma rheology into the brittle regime, and thus the ascent of high-viscosity magma can form discrete shear zones, comparable to tectonic faults, along conduit margins. Pseudotachylytes have, until now, rarely been noted in exogenous volcanic materials and seldom in active volcanic environments. This is despite the simultaneous occurrence of high pressures and differential stresses, which make high-viscosity magmas ideal candidates for the occurrence of frictional melting. Here, we compare the chemical, thermal, magnetic and structural properties of two candidate volcanic pseudotachylytes; one from Soufriere Hills (Montserrat) and one from Mount St. Helens (USA). Additionally, we present data from a set of high-velocity rotary shear experiments on the host materials of these natural pseudotachylytes in which melting was induced after just 10's of centimeters of slip at realistic extrusion velocities (0.4 - 1.6 ms-1) and low normal stresses (0.5-2 MPa). After 1-2 meters of slip a continuous melt layer formed, at which point friction decreased and the fault zone displayed slip-weakening behaviour. For volcanic conduits, this would facilitate temporarily elevated slip rates, or an increase in extrusion rate, and could cause transitions in dome morphology and eruption style. This study demonstrates that shear fracturing in magma or sliding along conduit margins can readily result in frictional melting. The conspicuous absence of pseudotachylytes in active volcanic environments is likely the result of exceptionally high background temperatures which precipitate near-equilibrium melting, thereby obviating one of the characteristic signatures of pseudotachylyte - glassy protomelts formed by selective melting of

  8. Right ventricular to pulmonary artery conduit instead of modified Blalock-Taussig shunt improves postoperative hemodynamics in newborns after the Norwood operation.

    Science.gov (United States)

    Mair, Rudolf; Tulzer, Gerald; Sames, Eva; Gitter, Roland; Lechner, Evelyn; Steiner, Jürgen; Hofer, Anna; Geiselseder, Gertraud; Gross, Christoph

    2003-11-01

    Perioperative mortality, prolonged postoperative recovery after the Norwood procedure, and mortality between stage I and stage II might be related to shunt physiology. A right ventricular to pulmonary artery conduit offers a banded physiology in contrast to a Blalock-Taussig shunt. The purpose of this study was to assess the hemodynamic differences and their consequences in the postoperative course between Norwood patients with a Blalock-Taussig shunt and those with a right ventricular to pulmonary artery conduit. From October 1999 until May 2002, 32 unselected consecutive patients underwent a Norwood procedure at the General Hospital Linz. The first 18 patients received a Blalock-Taussig shunt. In the remaining 14 patients we performed a right ventricular to pulmonary artery conduit. Both groups were compared. The diastolic blood pressure was significantly higher in the right ventricular to pulmonary artery conduit group (P <.001). Despite a higher FIO(2), PO(2) levels tended to be lower in the first 5 postoperative days. At the age of 3 months, catheterization laboratory data showed a lower Qp/Qs ratio in the same group (0.86 [0.78; 1] versus 1.55 [1.15; 1.6]; P =.005) and a higher dp/dt (955 [773; 1110] vs 776 [615; 907]; P =.018). (Descriptive data reflect medians and quartiles [in brackets].) Hospital survival was 72% in the Blalock-Taussig shunt group versus 93% in the right ventricular to pulmonary artery conduit group. Mortality between stage I and stage II was 23% in the Blalock-Taussig shunt group versus 0% in the right ventricular to pulmonary artery conduit group. A higher diastolic blood pressure and a lower Qp/Qs ratio were associated with a more stable and efficient circulation in patients with a right ventricular to pulmonary artery conduit. More intensive ventilatory support was necessary during the first postoperative days. We did not note any adverse effects of the ventriculotomy on ventricular performance.

  9. Impact of bed rest on conduit artery remodeling: effect of exercise countermeasures.

    NARCIS (Netherlands)

    Duijnhoven, N.T.L. van; Green, D.J.; Felsenberg, D.; Belavy, D.L.; Hopman, M.T.E.; Thijssen, D.H.J.

    2010-01-01

    Physical inactivity is a potent stimulus for vascular remodeling, leading to a marked decrease in conduit artery diameter. However, little is known about the impact of physical inactivity on artery wall thickness or wall:lumen ratio or the potential of exercise countermeasures to modify artery wall

  10. Enhancing Peripheral Nerve Regeneration with a Novel Drug-Delivering Nerve Conduit

    Science.gov (United States)

    2015-10-01

    our novel nerve conduit. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE...growth in dorsal root ganglion ( DRG ) cell culture Tasks/Subtasks: 1. In Vitro NGF/GNDF release kinetics experiments.......................... (Gale...Axonal growth of DRGs ................................................................ (Terry, Shea) (11-18months) Progress: We have started these

  11. Permeability Measurements of Rock Samples from Conduit Drilling at Unzen Volcano, Japan

    Science.gov (United States)

    Watanabe, T.; Shimizu, Y.; Noguchi, S.; Nakada, S.

    2006-12-01

    The last eruption of Unzen Volcano (1990-1995) was effusive to form lava domes, though magmas at depths are estimated to have contained volatile materials enough to cause explosive eruptions [e.g., Sato et al., 1995]. Most of volatile materials should have escaped from ascending magmas. The escape of gas is controlled by permeability of magmas and country rocks. Unzen Scientific Drilling Project sampled both the latest conduit and its country rock (USDP-4). In order to understand degassing processes, we have measured the permeability of these rock samples. Four cube samples with edges of 25 mm were cut from USDP-4 cores C1, C12 (country rock), C13 and C14 (conduit). Sample C1 is considered as Old Unzen Lava, and Sample C12 volcanic breccia. The transient pulse method was employed to measure the permeability. It applies a step of the fluid pressure difference across a specimen, and measures the decay rate of the fluid pressure difference. This method can be applied to samples with very low permeability, since it determines the permeability without measuring the fluid flux. Nitrogen gas was used as a pore fluid. Our permeametry system is built in a pressure vessel, and the confining pressure and the pore fluid pressure can be controlled independently. The temperature of the measurement system is kept constant within 0.1 degree. The temperature control and the background leak rate limit the measurable permeability to be higher than 10^{-20} m2. Measurements were first conducted under the atmospheric pressure. The permeability in a rock sample varies with the direction by a factor less than 5. Sample C1 has the lowest permeability (10^{-19} m2), and Sample C12 the highest value (10^{-17 m2). The permeability of C13 and C14 is of the order of 10^{- 18} m2. Though only a trace of vesicles can be seen in conduit samples, the interconnection is still maintained. The pressure dependence of the permeability is now investigated up to 50 MPa. The permeability of C13 and C14

  12. Terrestrial analogs to lunar sinuous rilles - Kauhako Crater and channel, Kalaupapa, Molokai, and other Hawaiian lava conduit systems

    International Nuclear Information System (INIS)

    Coombs, C.R.; Hawke, B.R.; Wilson, L.

    1990-01-01

    Two source vents, one explosive and one effusive erupted to form a cinder cone and low lava shield that together compose the Kalaupapa peninsula of Molokai, Hawaii, A 50-100-m-wide channel/tube system extends 2.3 km northward from kauhako crater in the center of the shield. Based on modeling, a volume of up to about 0.2 cu km of lava erupted at a rate of 260 cu m/sec to flow through the Kauhako conduit system in one of the last eruptive episodes on the peninsula. Channel downcutting by thermal erosion occurred at a rate of about 10 micron/sec to help form the 30-m-deep conduit. Two smaller, secondary tube systems formed east of the main lava channel/tube. Several other lava conduit systems on the islands of Oahu and Hawaii were also compared to the Kauhako and lunar sinuous rille systems. These other lava conduits include Whittington, Kupaianaha, and Mauna Ulu lava tubes. Morphologically, the Hawaiian tube systems studied are very similar to lunar sinuous rilles in that they have deep head craters, sinuous channels, and gentle slopes. Thermal erosion is postulated to be an important factor in the formation of these terrestrial channel systems and by analogy is inferred to be an important process involved in the formation of lunar sinuous rilles. 28 refs

  13. FATIGUE PROPERTIES OF MODIFIED 316LN STAINLESS STEEL AT 4 K FOR HIGH FIELD CABLE-IN-CONDUIT APPLICATIONS

    International Nuclear Information System (INIS)

    Toplosky, V. J.; Walsh, R. P.; Han, K.

    2010-01-01

    Cable-In-Conduit-Conductor (CICC) alloys, exposed to Nb 3 Sn reaction heat-treatments, such as modified 316LN require a design specific database. A lack of fatigue life data (S-n curves) that could be applied in the design of the ITER CS and the NHMFL Series Connected Hybrid magnets is the impetus for the research presented here. The modified 316LN is distinguished by a lower carbon content and higher nitrogen content when compared to conventional 316LN. Because the interstitial alloying elements affect the mechanical properties significantly, it is necessary to characterize this alloy in a systematic way. In conjunction, to ensure magnet reliability and performance, several criteria and expectations must be met, including: high fatigue life at the operating stresses, optimal stress management at cryogenic temperatures and thin walled conduit to reduce coil mass. Tension-tension load control axial fatigue tests have good applicability to CICC solenoid magnet design, thus a series of 4 K strength versus fatigue life curves have been generated. In-situ samples of 316LN base metal, seam welded, butt welded and seam plus butt welded are removed directly from the conduit in order to address base and weld material fatigue life variability. The more than 30 fatigue tests show good grouping on the fatigue life curve and allow discretionary 4 K fatigue life predictions for conduit made with modified 316LN.

  14. On magma fragmentation by conduit shear stress: Evidence from the Kos Plateau Tuff, Aegean Volcanic Arc

    Science.gov (United States)

    Palladino, Danilo M.; Simei, Silvia; Kyriakopoulos, Konstantinos

    2008-12-01

    Large silicic explosive eruptions are the most catastrophic volcanic events. Yet, the intratelluric mechanisms underlying are not fully understood. Here we report a field and laboratory study of the Kos Plateau Tuff (KPT, 161 ka, Aegean Volcanic Arc), which provides an excellent geological example of conduit processes that control magma vesiculation and fragmentation during intermediate- to large-scale caldera-forming eruptions. A prominent feature of the KPT is the occurrence of quite unusual platy-shaped tube pumice clasts in pyroclastic fall and current deposits from the early eruption phases preceding caldera collapse. On macroscopic and SEM observations, flat clast faces are elongated parallel to tube vesicles, while transverse surfaces often occur at ~ 45° to vesicle elongation. This peculiar pumice texture provides evidence of high shear stresses related to strong velocity gradients normal to conduit walls, which induced vesiculation and fragmentation of the ascending magma. Either an increasing mass discharge rate without adequate enlargement of a narrow central feeder conduit or a developing fissure-like feeder system related to incipient caldera collapse provided suitable conditions for the generation of plate tube pumice within magma volumes under high shear during the pre-climactic KPT eruption phases. This mechanism implies that the closer to the conduit walls (where the stronger are the velocity gradients) the larger was the proportion of plate vs. conventional (lensoid) juvenile fragments in the ascending gas-pyroclast mixture. Consequently, plate pumice clasts were mainly entrained in the outer portions of the jet and convecting regions of a sustained, Plinian-type, eruption column, as well as in occasional lateral blast currents generated at the vent. As a whole, plate pumice clasts in the peripheral portions of the column were transported at lower altitudes and deposited by fallout or partial collapse closer to the vent relative to lensoid ones

  15. What goes up might come down: Backflow in the conduits of persistently degassing volcanoes and ramifications for melt-inclusion analysis

    Science.gov (United States)

    Suckale, J.; Qin, Z.; Picchi, D.; Keller, T.

    2017-12-01

    Many active volcanoes erupt significantly less magma than they degas, implying that large quantities of magma must descend back into the plumbing system after degassing. The resulting bidirectional flow field in the volcanic conduit is fundamentally unstable. These instabilities are important to understand, because they likely control the episodicity of eruptive behavior observed at persistently degassing volcanoes. Laboratory experiments have provided invaluable insights into the flow regimes that may arise in volcanic conduits, but are not straightforward to scale up to volcanic systems. The goal of this study is to use direct numerical simulations to virtually reproduce the analogue experiments by Stevenson and Blake, 1998, compare them to simple analytical models and gain insights into the different flow regimes and interface instabilities observed in actual volcanic conduits. Direct numerical simulations provide a compelling complement to analogue experiments, because they are not constrained by the scales or flow properties achievable in a laboratory setting. By linking virtual and analogue experiments, we show that the interface between ascending and descending fluid is not usually stationary in volcanic conduits (see fig). The intuition that buoyant, volatile-rich magma moves up while heavy, degassed magma moves down is hence not generally true in bidirectional conduit flow. Instead, our results show that a potentially significant portion of the volatile-rich magma flows downwards despite its positive buoyancy - a process commonly referred to as backflow. The existence of backflow in volcanic conduits has potentially important ramifications for understanding melt-inclusion trends, because it affects exsolved and dissolved volatile components differently. Our preliminary results suggest that carbon dioxide bubbles exsolved at depth tend to decouple from the backflow and escape into the upward moving portion of the fluid, while dissolved water is recycled

  16. Comparison of Fiber Optic and Conduit Attenuated Total Reflection (ATR) Fourier Transform Infrared (FT-IR) Setup for In-Line Fermentation Monitoring.

    Science.gov (United States)

    Koch, Cosima; Posch, Andreas E; Herwig, Christoph; Lendl, Bernhard

    2016-12-01

    The performance of a fiber optic and an optical conduit in-line attenuated total reflection mid-infrared (IR) probe during in situ monitoring of Penicillium chrysogenum fermentation were compared. The fiber optic probe was connected to a sealed, portable, Fourier transform infrared (FT-IR) process spectrometer via a plug-and-play interface. The optical conduit, on the other hand, was connected to a FT-IR process spectrometer via a knuckled probe with mirrors that had to be adjusted prior to each fermentation, which were purged with dry air. Penicillin V (PenV) and its precursor phenoxyacetic acid (POX) concentrations were determined by online high-performance liquid chromatography and the obtained concentrations were used as reference to build partial least squares regression models. Cross-validated root-mean-square errors of prediction were found to be 0.2 g L -1 (POX) and 0.19 g L -1 (PenV) for the fiber optic setup and 0.17 g L -1 (both POX and PenV) for the conduit setup. Higher noise-levels and spectrum-to-spectrum variations of the fiber optic setup lead to higher noise of estimated (i.e., unknown) POX and PenV concentrations than was found for the conduit setup. It seems that trade-off has to be made between ease of handling (fiber optic setup) and measurement accuracy (optical conduit setup) when choosing one of these systems for bioprocess monitoring. © The Author(s) 2016.

  17. Cardiovascular effects of right ventricle-pulmonary artery valved conduit implantation in experimental pulmonic stenosis

    International Nuclear Information System (INIS)

    Saida, Y.; Tanaka, R.; Fukushima, R.; Hoshi, K.; Hira, S.; Soda, A.; Iizuka, T.; Ishikawa, T.; Nishimura, T.; Yamane, Y.

    2009-01-01

    Right ventricle (RV)-pulmonary artery (PA) valved conduit (RPVC) implantation decreases RV systolic pressure in pulmonic stenosis (PS) by forming a bypass route between the RV and the PA. The present study evaluates valved conduits derived from canine aortae in a canine model of PS produced by pulmonary artery banding (PAB). Pulmonary stenosis was elicited using PAB in 10 conditioned beagles aged 8 months. Twelve weeks after PAB, the dogs were assigned to one group that did not undergo surgical intervention and another that underwent RPVC using denacol-treated canine aortic valved grafts (PAB+RPVC). Twelve weeks later, the rate of change in the RV-PA systolic pressure gradient was significantly decreased in the PAB+RPVC, compared with the PAB group (60.5+-16.7% vs. 108.9+-22.9%; p0.01). In addition, the end-diastolic RV free wall thickness (RVFWd) was significantly reduced in the PAB+RPVC, compared with the PAB group (8.2+-0.2 vs. 9.4+-0.7 mm; p0.05). Thereafter, regurgitation was not evident beyond the conduit valve and the decrease in RV pressure overload induced by RPVC was confirmed. The present results indicate that RPVC can be performed under a beating heart without cardiopulmonary bypass and adapted to dogs with various types of PS, including 'supra valvular' PS or PS accompanied by dysplasia of the pulmonary valve. Therefore, we consider that this method is useful for treating PS in small animals

  18. Sexual Function after Non-Nerve-Sparing Radical Cystoprostatectomy: A Comparison between Ileal Conduit Urinary Diversion and Orthotopic Ileal Neobladder Substitution

    Directory of Open Access Journals (Sweden)

    M.A Asgari

    2013-07-01

    Full Text Available Objective To compare the erectile function (EF and sexual desire (SD in men after radical cystoprostatectomy (RCP who had either an ileal conduit urinary diversion or orthotropic ileal neobladder substitution. Materials and Methods Eighty one sexually active men with bladder cancer were enrolled in this prospective study. After RCP according to patients' preferences they underwent either ileal conduit urinary diversion (n = 41 or orthotropic ileal neobladder substitution (n = 40. EF and SD were assessed using International Index of Erectile Function (IIEF questionnaire. Patients were assessed at 4-week before surgery and were followed up at 1, 6, and 12-month postoperatively using the same questionnaire. Results Postoperatively the EF and SD domains deteriorated significantly in both groups, but in a small proportion of the patients submitted to ileal neobladder they gradually improved with time (P = 0.006. At 12-month postoperative period, 4 (9.8% and 14 (35.0% patients in ileal conduit and ileal neobladder groups were able to achieve erections hard enough for vaginal penetration and maintained their erection to completion of intercourse, respectively (P = 0.006. Among patients in the ileal conduit and ileal neobladder groups, additional 4 (9.8% and 7 (17.1% patients were able to get some erection, but were unable to maintain their erection to completion of intercourse (P = 0.02. At 12-month follow up period 24.4% of the ileal conduit and 45.0% of the ileal neobladder patients rated their sexual desire very high or high (P = 0.01. Conclusion When performed properly, orthotopic ileal neobladder substitution after RCP offers better long-term results in terms of EF and SD.

  19. 76 FR 53678 - Calleguas Municipal Water District Notice of Surrender of Exemption (Conduit)

    Science.gov (United States)

    2011-08-29

    ... Municipal Water District Notice of Surrender of Exemption (Conduit) Pursuant to section 4.95(a) of the Commission's regulations,\\1\\ Calleguas Municipal Water District filed with the Commission a petition to... Municipal Water District, 87 FERC ] 62,256 (1999). \\3\\ See filing of July 11, 2011 by Calleguas Municipal...

  20. Incorporation of cooling-induced crystallisation into a 2-dimensional axisymmetric conduit heat flow model

    Science.gov (United States)

    Heptinstall, D. A.; Neuberg, J. W.; Bouvet de Maisonneuve, C.; Collinson, A.; Taisne, B.; Morgan, D. J.

    2015-12-01

    Heat flow models can bring new insights into the thermal and rheological evolution of volcanic systems. We shall investigate the thermal processes and timescales in a crystallizing, static magma column, with a heat flow model of Soufriere Hills Volcano (SHV), Montserrat. The latent heat of crystallization is initially computed with MELTS, as a function of pressure and temperature for an andesitic melt (SHV groundmass starting composition). Three fractional crystallization simulations are performed; two with initial pressures of 34MPa (runs 1 & 2) and one of 25MPa (run 3). Decompression rate was varied between 0.1MPa/°C (runs 1 & 3) and 0.2MPa/°C (run 2). Natural and experimental matrix glass compositions are accurately reproduced by all MELTS runs. The cumulative latent heat released for runs 1, 2 and 3 differs by less than 9% (8.69e5 J/kg*K, 9.32e5 J/kg*K, and 9.49e5 J/kg*K respectively). The 2D axisymmetric conductive cooling simulations consider a 30m-diameter conduit that extends from the surface to a depth of 1500m (34MPa). The temporal evolution of temperature is closely tracked at depths of 10m, 750m and 1400m in the center of the conduit, at the conduit walls, and 20m from the walls into the host rock. Following initial cooling by 7-15oC at 10m depth inside the conduit, the magma temperature rebounds through latent heat release by 32-35oC over 85-123 days to a maximum temperature of 1002-1005oC. At 10 m depth, it takes 4.1-9.2 years for the magma column to cool over 108-130oC and crystallize to 75wt%, at which point it cannot be easily remobilized. It takes 11-31.5 years to reach the same crystallinity at 750-1400m depth. We find a wide range in cooling timescales, particularly at depths of 750m or greater, attributed to the initial run pressure and dominant latent heat producing crystallizing phases (Quartz), where run 1 cools fastest and run 3 cools slowest. Surface cooling by comparison has the strongest influence on the upper tens of meters in all

  1. Construction of nerve guide conduits from cellulose/soy protein composite membranes combined with Schwann cells and pyrroloquinoline quinone for the repair of peripheral nerve defect

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Lihua [Department of Biomedical Engineering, School of Basic Medical Sciences, Wuhan University, Wuhan 430071 (China); Center of Molecular Medicine, School of Medicine, Hubei University of Arts and Sciences, Xiangyang 441053 (China); Gan, Li; Liu, Yongming; Tian, Weiqun; Tong, Zan [Department of Biomedical Engineering, School of Basic Medical Sciences, Wuhan University, Wuhan 430071 (China); Wang, Xiong; Huselstein, Celine [Ingénierie Moléculaire et Physiopathologie Articulaire (IMoPA), UMR 7365 CNRS – Université de Lorraine, Biopôle, 54500 Vandoeuvre-lès-Nancy (France); Chen, Yun, E-mail: yunchen@whu.edu.cn [Department of Biomedical Engineering, School of Basic Medical Sciences, Wuhan University, Wuhan 430071 (China)

    2015-02-20

    Regeneration and functional reconstruction of peripheral nerve defects remained a significant clinical challenge. Nerve guide conduits, with seed cells or neurotrophic factors (NTFs), had been widely used to improve the repair and regeneration of injured peripheral nerve. Pyrroloquinoline quinone (PQQ) was an antioxidant that can stimulate nerve growth factors (NGFs) synthesis and accelerate the Schwann cells (SCs) proliferation and growth. In present study, three kinds of nerve guide conduits were constructed: one from cellulose/SPI hollow tube (CSC), another from CSC combined with SCs (CSSC), and the third one from CSSC combined with PQQ (CSSPC), respectively. And then they were applied to bridge and repair the sciatic nerve defect in rats, using autograft as control. Effects of different nerve guide conduits on the nerve regeneration were comparatively evaluated by general analysis, sciatic function index (SFI) and histological analysis (HE and TEM). Newly-formed regenerative nerve fibers were observed and running through the transparent nerve guide conduits 12 weeks after surgery. SFI results indicated that the reconstruction of motor function in CSSPC group was better than that in CSSC and CSC groups. HE images from the cross-sections and longitudinal-sections of the harvested regenerative nerve indicated that regenerative nerve fibers had been formed and accompanied with new blood vessels and matrix materials in the conduits. TEM images also showed that lots of fresh myelinated and non-myelinated nerve fibers had been formed. Parts of vacuolar, swollen and abnormal axons occurred in CSC and CSSC groups, while the vacuolization and swell of axons was the least serious in CSSPC group. These results indicated that CSSPC group had the most ability to repair and reconstruct the nerve structure and functions due to the comprehensive contributions from hollow CSC tube, SCs and PQQ. As a result, the CSSPC may have the potential for the applications as nerve guide

  2. The Malnutrition-Related Increase in Early Visceralization of Leishmania donovani Is Associated with a Reduced Number of Lymph Node Phagocytes and Altered Conduit System Flow

    Science.gov (United States)

    Ibrahim, Marwa K.; Barnes, Jeffrey L.; Anstead, Gregory M.; Jimenez, Fabio; Travi, Bruno L.; Peniche, Alex G.; Osorio, E. Yaneth; Ahuja, Seema S.; Melby, Peter C.

    2013-01-01

    In a murine model of moderate childhood malnutrition we found that polynutrient deficiency led to a 4–5-fold increase in early visceralization of L. donovani (3 days post-infection) following cutaneous infection and a 16-fold decrease in lymph node barrier function (pmalnutrition-related parasite dissemination we analyzed the cellularity, architecture, and function of the skin-draining lymph node. There was no difference in the localization of multiple cell populations in the lymph node of polynutrient deficient (PND) mice, but there was reduced cellularity with fewer CD11c+dendritic cells (DCs), fibroblastic reticular cells (FRCs), MOMA-2+ macrophages, and CD169+ subcapsular sinus macrophage (p<0.05 for all) compared to the well-nourished (WN) mice. The parasites were equally co-localized with DCs associated with the lymph node conduit network in the WN and PND mice, and were found in the high endothelial venule into which the conduits drain. When a fluorescent low molecular weight (10 kD) dextran was delivered in the skin, there was greater efflux of the marker from the lymph node conduit system to the spleens of PND mice (p<0.04), indicating that flow through the conduit system was altered. There was no evidence of disruption of the conduit or subcapsular sinus architecture, indicating that the movement of parasites into the subcortical conduit region was due to an active process and not from passive movement through a leaking barrier. These results indicate that the impaired capacity of the lymph node to act as a barrier to dissemination of L. donovani infection is associated with a reduced number of lymph node phagocytes, which most likely leads to reduced capture of parasites as they transit through the sinuses and conduit system. PMID:23967356

  3. How to quantify conduits in wood?

    Science.gov (United States)

    Scholz, Alexander; Klepsch, Matthias; Karimi, Zohreh; Jansen, Steven

    2013-01-01

    Vessels and tracheids represent the most important xylem cells with respect to long distance water transport in plants. Wood anatomical studies frequently provide several quantitative details of these cells, such as vessel diameter, vessel density, vessel element length, and tracheid length, while important information on the three dimensional structure of the hydraulic network is not considered. This paper aims to provide an overview of various techniques, although there is no standard protocol to quantify conduits due to high anatomical variation and a wide range of techniques available. Despite recent progress in image analysis programs and automated methods for measuring cell dimensions, density, and spatial distribution, various characters remain time-consuming and tedious. Quantification of vessels and tracheids is not only important to better understand functional adaptations of tracheary elements to environment parameters, but will also be essential for linking wood anatomy with other fields such as wood development, xylem physiology, palaeobotany, and dendrochronology.

  4. Characterization of molecule and particle transport through nanoscale conduits

    Science.gov (United States)

    Alibakhshi, Mohammad Amin

    Nanofluidic devices have been of great interest due to their applications in variety of fields, including energy conversion and storage, water desalination, biological and chemical separations, and lab-on-a-chip devices. Although these applications cross the boundaries of many different disciplines, they all share the demand for understanding transport in nanoscale conduits. In this thesis, different elusive aspects of molecule and particle transport through nanofluidic conduits are investigated, including liquid and ion transport in nanochannels, diffusion- and reaction-governed enzyme transport in nanofluidic channels, and finally translocation of nanobeads through nanopores. Liquid or solvent transport through nanoconfinements is an essential yet barely characterized component of any nanofluidic systems. In the first chapter, water transport through single hydrophilic nanochannels with heights down to 7 nm is experimentally investigated using a new measurement technique. This technique has been developed based on the capillary flow and a novel hybrid nanochannel design and is capable of characterizing flow in both single nanoconduits as well as nanoporous media. The presence of a 0.7 nm thick hydration layer on hydrophilic surfaces and its effect on increasing the hydraulic resistance of the nanochannels is verified. Next, ion transport in a new class of nanofluidic rectifiers is theoretically and experimentally investigated. These so called nanofluidic diodes are nanochannels with asymmetric geometries which preferentially allow ion transport in one direction. A nondimensional number as a function of electrolyte concentration, nanochannel dimensions, and surface charge is derived that summarizes the rectification behavior of this system. In the fourth chapter, diffusion- and reaction-governed enzyme transport in nanofluidic channels is studied and the theoretical background necessary for understanding enzymatic activity in nanofluidic channels is presented. A

  5. Natural Occurring Silks and Their Analogues as Materials for Nerve Conduits

    OpenAIRE

    Christine Radtke

    2016-01-01

    Spider silk and its synthetic derivatives have a light weight in combination with good strength and elasticity. Their high cytocompatibility and low immunogenicity make them well suited for biomaterial products such as nerve conduits. Silk proteins slowly degrade enzymatically in vivo, thus allowing for an initial therapeutic effect such as in nerve scaffolding to facilitate endogenous repair processes, and then are removed. Silks are biopolymers naturally produced by many species of arthropo...

  6. Analysis of aortic root surgery with composite mechanical aortic valve conduit and valve-sparing reconstruction.

    Science.gov (United States)

    Dias, Ricardo Ribeiro; Mejia, Omar Asdrubal Vilca; Fiorelli, Alfredo Inácio; Pomerantzeff, Pablo Maria Alberto; Dias, Altamiro Ribeiro; Mady, Charles; Stolf, Noedir Antonio Groppo

    2010-01-01

    Comparative analysis of early and late results of aortic root reconstruction with aortic valve sparing operations and the composite mechanical valve conduit replacement. From November 2002 to September 2009, 164 consecutive patients with mean age 54 ± 15 years, 115 male, underwent the aortic root reconstruction (125 mechanical valve conduit replacements and 39 valve sparing operations). Sixteen percent of patients had Marfan syndrome and 4.3% had bicuspid aortic valve. One hundred and forty-four patients (88%) were followed for a mean period of 41.1 ± 20.8 months. The hospital mortality was 4.9%, 5.6% in operations with valved conduits and 2.6% in the valve sparing procedures (P valve sparing operations, respectively (95% CI = 70% - 95%, P = 0.001), (95% CI = 82% - 95% P = 0.03) and (95% CI = 81% - 95%, P = 0.03). Multivariate analysis showed that creatinine greater than 1.4 mg/dl, Cabrol operation and renal dialysis were predictors of mortality, respectively, with occurrence chance of 6 (95% CI = 1.8 - 19.5, P = 0.003), 12 (95% CI = 3 - 49.7, P = 0.0004) and 16 (95% CI = 3.6 - 71.3, P = 0.0002). The aortic root reconstruction has a low early and late mortality, high survival free of complications and low need for reoperation. During the late follow-up, valve sparing aortic root reconstructions presented fewer incidences of bleeding, thromboembolic events and endocarditis.

  7. Experimental study on scale removal from special-shaped conduits through underwater electrical discharge

    International Nuclear Information System (INIS)

    Cao, Y; Wang, Z Q; Li, G F; Wu, Y; Zhou, J J

    2013-01-01

    Underwater electrical discharge technology is an innovative technique that can be used to enhance the stress intensity of water and improve the load addition. The technique enlarges the section area and compresses the surrounding water using a high-powered shock wave, which is induced by an underwater electrical discharge. This paper investigates the effectiveness of scale removal for special-shaped conduits employing underwater electrical discharge. Experimental results show that the pressure wave generated by underwater electrical discharge is capable of eliminating scale in special-shaped conduits. The data indicates that when the capacitance of the parallel-pulsed capacitors was 4 μF, the high pulsed power voltage was 33 kV and the primary discharge gap was 48 mm, the result of scale removal was remarkable. In laboratory tests, the scale of special equipment was removed to a great extent by this method. Because of its effectiveness and low cost, this method improves the practice and extends the lifetime of such equipment, and thus has potential application and economic value.

  8. Rapid prototyping of a double-layer polyurethane-collagen conduit for peripheral nerve regeneration.

    Science.gov (United States)

    Cui, Tongkui; Yan, Yongnian; Zhang, Renji; Liu, Li; Xu, Wei; Wang, Xiaohong

    2009-03-01

    A new technique for preparing double-layer polyurethane (PU)-collagen nerve conduits for peripheral nerve repair via a double-nozzle, low-temperature, deposition manufacturing (DLDM) system has been developed. The DLDM system is based on a digital prototyping approach, and uses a combination of thermally induced phase separation and freeze-drying. With this system, two kinds of biomaterials with different properties can be combined to produce scaffold structures with good biocompatibility in the inner layer and with the desired mechanical strength protruded by the outer. The forming precision is high, the wall thickness can be controlled, and a tight connection between the two layers can be achieved. The effects of changing the processing parameters and the material temperature on the structure of the scaffolds have been investigated. Additionally, the effect of material concentration on the mechanical strength and hydrophilic properties of the scaffolds has also been studied. Ideal peripheral nerve repair conduits, comprising an outer microporous layer of PU and internal oriented filaments of collagen, have been manufactured through optimizing the processing parameters and the biomaterial concentrations.

  9. Opportunities for Energy Development in Water Conduits: A Report Prepared in Response to Section 7 of the Hydropower Regulatory Efficiency Act of 2013

    Energy Technology Data Exchange (ETDEWEB)

    Sale, Michael J. [BCS, Incorporated, Laurel, MD (United States); Bishop, Norman A. [Knight Piesold, Chicago, IL (United States); Reiser, Sonya L. [Knight Piesold, Chicago, IL (United States); Johnson, Kurt [Telluride Energy LLC, Grand Junction, CO (United States); Bailey, Andrea C. [BCS, Incorporated, Laurel, MD (United States); Frank, Anthony [BCS, Incorporated, Laurel, MD (United States); Smith, Brennan T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Environmental Sciences Division

    2014-09-01

    In Section 7 of the Hydropower Regulatory Efficiency Act (HREA) of 2013 (P.L. 113-23), Congress directed the U.S. Department of Energy (DOE) to prepare an analysis of conduit hydropower opportunities available in the United States and to present case studies that describe the potential energy generation from these types of hydropower projects. Those analyses have been included in a new DOE report to Congress, and this ORNL/TM provides additional technical details supporting that report. Conduit hydropower offers important new ways to enhance renewable energy portfolios in the United States, as well as to increase the energy efficiency of water delivery systems. Conduit hydropower projects are constructed on existing water-conveyance structures, such as irrigation canals or pressurized pipelines that deliver water to municipalities, industry, or agricultural water users. Although water conveyance infrastructures are usually designed for non-power purposes, new renewable energy can often be harvested from them without affecting their original purpose and without the need to construct new dams or diversions. Conduit hydropower differs from more conventional hydropower development in that it is generally not located on natural rivers or waterways and therefore does not involve the types of environmental impacts that are associated with hydropower. The addition of hydropower to existing water conduits can provide valuable new revenue sources from clean, renewable energy. The new energy can be used within the existing water distribution systems to offset other energy demands, or it can be sold into regional transmission systems.

  10. Numerical simulation of freshwater/seawater interaction in a dual-permeability karst system with conduits: the development of discrete-continuum VDFST-CFP model

    Science.gov (United States)

    Xu, Zexuan; Hu, Bill

    2016-04-01

    Dual-permeability karst aquifers of porous media and conduit networks with significant different hydrological characteristics are widely distributed in the world. Discrete-continuum numerical models, such as MODFLOW-CFP and CFPv2, have been verified as appropriate approaches to simulate groundwater flow and solute transport in numerical modeling of karst hydrogeology. On the other hand, seawater intrusion associated with fresh groundwater resources contamination has been observed and investigated in numbers of coastal aquifers, especially under conditions of sea level rise. Density-dependent numerical models including SEAWAT are able to quantitatively evaluate the seawater/freshwater interaction processes. A numerical model of variable-density flow and solute transport - conduit flow process (VDFST-CFP) is developed to provide a better description of seawater intrusion and submarine groundwater discharge in a coastal karst aquifer with conduits. The coupling discrete-continuum VDFST-CFP model applies Darcy-Weisbach equation to simulate non-laminar groundwater flow in the conduit system in which is conceptualized and discretized as pipes, while Darcy equation is still used in continuum porous media. Density-dependent groundwater flow and solute transport equations with appropriate density terms in both conduit and porous media systems are derived and numerically solved using standard finite difference method with an implicit iteration procedure. Synthetic horizontal and vertical benchmarks are created to validate the newly developed VDFST-CFP model by comparing with other numerical models such as variable density SEAWAT, couplings of constant density groundwater flow and solute transport MODFLOW/MT3DMS and discrete-continuum CFPv2/UMT3D models. VDFST-CFP model improves the simulation of density dependent seawater/freshwater mixing processes and exchanges between conduit and matrix. Continuum numerical models greatly overestimated the flow rate under turbulent flow

  11. Aptitude visuelle à la conduite automobile: exemple des candidats au permis de conduire à Libreville

    Science.gov (United States)

    Souhail, Hassane; Assoumou, Prudence; Birinda, Hilda; Mengome, Emmanuel Mve

    2015-01-01

    L'objectif était d’évaluer l'aptitude visuelle à la conduite automobile des candidats au permis de conduire à Libreville. Il s'agissait d'une étude transversale, descriptive et analytique, qui s'est déroulée à Libreville pendant la période du 4 avril 2012 au 14 juillet 2012 (soit 4 mois et 10 jours). La population d’étude concernait les candidats soumis aux épreuves d'obtention du permis de conduire. Nous avons inclus dans notre travail, les candidats, ayant donné leur consentement par écrit et exclus ceux refusant d'adhérer à l'enquête. Les variables étudiées concernaient l’âge, le sexe, la population d’étude, l'activité professionnelle, l'acuité visuelle de loin et de près, la vision des couleurs, la catégorie du permis de conduire, et l'aptitude visuelle à la conduite automobile. La saisie et l'analyse des données ont été collectées au moyen d'une fiche d'enquête standardisée; après vérification et validation, elles ont été saisies sur le logiciel Excel Windows et analysées sur le logiciel Epi Info version 3.5.1. L’âge moyen des 406 candidats était de 29 ans ± 6,65 ans avec des extrêmes allant de 17 ans à 52 ans. Les hommes représentaient 283 (69,7%) et les femmes 123 (30,3%), soit un ratio de 2,3. Les fonctionnaires étaient retrouvés dans 39,4 % des cas, suivi des élèves-étudiants dans 33,5%. Dans notre population d’étude, 71 sur 406 candidats avaient une baisse de l'acuité visuelle de loin, soit 17,5%. Dans notre série, nous avons retrouvés 34 candidats âgés de 40 ans et plus, et seulement 14 candidats (41,2%) avaient une baisse de l'acuité visuelle de près. La quasi-totalité des patients avaient une vision de couleurs normale (99,5%), cependant 2 candidats avaient une vision de couleurs anormale, soit une prévalence de 0,5%. Dans notre échantillon, 403 (99,3%) sollicitaient un permis de conduire de catégorie léger (perms A, A1, B, F) et 3 (0,7%) sollicitaient un permis de conduire de type

  12. Percutaneous transthoracic computed tomography-guided AICD insertion in a patient with extracardiac Fontan conduit.

    LENUS (Irish Health Repository)

    Murphy, Darra T

    2011-02-01

    Percutaneous pulmonary venous atrial puncture was performed under computed tomography guidance to successfully place an automated implantable cardiac defibrillator into a 26-year-old patient with extracardiac Fontan conduit who had presented with two out-of-hospital cardiac arrests. The procedure avoided the need for lead placement at thoracotomy.

  13. Visualized Evaluation of Blood Flow to the Gastric Conduit and Complications in Esophageal Reconstruction.

    Science.gov (United States)

    Noma, Kazuhiro; Shirakawa, Yasuhiro; Kanaya, Nobuhiko; Okada, Tsuyoshi; Maeda, Naoaki; Ninomiya, Takayuki; Tanabe, Shunsuke; Sakurama, Kazufumi; Fujiwara, Toshiyoshi

    2018-03-01

    Evaluation of the blood supply to gastric conduits is critically important to avoid complications after esophagectomy. We began visual evaluation of blood flow using indocyanine green (ICG) fluorescent imaging in July 2015, to reduce reconstructive complications. In this study, we aimed to statistically verify the efficacy of blood flow evaluation using our simplified ICG method. A total of 285 consecutive patients who underwent esophagectomy and gastric conduit reconstruction were reviewed and divided into 2 groups: before and after introduction of ICG evaluation. The entire cohort and 68 patient pairs after propensity score matching (PS-M) were evaluated for clinical outcomes and the effect of visualized evaluation on reducing the risk of complication. The leakage rate in the ICG group was significantly lower than in the non-ICG group for each severity grade, both in the entire cohort (285 subjects) and after PS-M; the rates of other major complications, including recurrent laryngeal nerve palsy and pneumonia, were not different. The duration of postoperative ICU stay was approximately 1 day shorter in the ICG group than in the non-ICG group in the entire cohort, and approximately 2 days shorter after PS-M. Visualized evaluation of blood flow with ICG methods significantly reduced the rate of anastomotic complications of all Clavien-Dindo (CD) grades. Odds ratios for ICG evaluation decreased with CD grade (0.3419 for CD ≥ 1; 0.241 for CD ≥ 2; and 0.2153 for CD ≥ 3). Objective evaluation of blood supply to the reconstructed conduit using ICG fluorescent imaging reduces the risk and degree of anastomotic complication. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Robotic Assisted Radical Cystoprostatectomy and Intracorporeal Ileal Conduit Urinary Diversion for a Kidney Transplant Recipient

    Directory of Open Access Journals (Sweden)

    Peter A. Caputo

    Full Text Available ABSTRACT Introduction and Objectives: Robotic assisted radical cystectomy (RARC is an alternative to open radical cystectomy. As experience is gained with the RARC approach the technique is being applied to more complex surgical cases. We describe here our technique for RARC with intracorporeal ileal conduit urinary diversion for a renal transplant recipient. Materials and Methods: The patient is a 60-year old man with high-grade muscle invasive bladder cancer. He has a history of renal failure due to polycystic kidney disease and received a deceased donor renal transplant in 2008. His hospital course at time of transplant was complicated by low-level BK virus viremia. Interestingly his trans-urethral bladder tumor resection specimen at time of bladder cancer diagnosis stained positive for SV40. His native kidneys were anuric so bilateral laparoscopic nephrectomy was performed in a staged fashion 2 weeks prior to RARC. Our surgical technique utilizes 6 trocars, of note a 12-mm assistant trocar is placed 1 cm superior to the pubic symphysis, and this trocar is solely used to pass a laparoscopic stapler to facilitate the excision of the ileal segment and the stapled enteric anastomosis. Surgical steps include: identification of native ureters bilaterally (removed en bloc with the bladder specimen; identification of the transplanted ureter at the right bladder dome; posterior bladder and prostate dissection along Denonvilliers’ fascia; development of the space of Retzius; ligation and transection of the bladder and prostate vascular bundles; apical prostate dissection and transection of urethra; left pelvic lymphadenectomy; ilium resection for creation of the ileal conduit; stapled enteric anastomosis; ureteroileal anastomosis; maturation of the ileal conduit stoma. Results: The surgery had no intraoperative complications. Operative time was 443 minutes (7.4 hours. Estimated blood loss was 250 cc. Length of hospital stay was 5 days. The patient

  15. Engineering based assessment for a shape design of a pediatric ePTFE pulmonary conduit valve.

    Science.gov (United States)

    Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Miura, Hidekazu; Mura, Seitaro; Yamagishi, Masaaki

    2016-08-01

    The authors examined the hemodynamic characteristics of expanded polytetrafluoroethylene (ePTFE) pulmonary valved conduits quantitatively by our originally developed pediatric pulmonary mechanical circulatory system, in order to suggest the optimal shape design. The system consisted of pneumatically driven right atrium and ventricle model, a pulmonary valve chamber, and elastic pulmonary compliance model with peripheral vascular resistance units, a venous reservoir. We employed two different types of ePTFE valve and evaluated the relationship between the leaflets motion and hemodynamic characteristics by using a high-speed video camera. As a result, we successfully reproduced hemodynamic simulations in our pediatric pulmonary mock system. We confirmed that the presence of bulging sinuses in the pulmonary valved conduit reduced the transvalvular energy loss and increased the valve opening area during systolic period. Our engineering-based in vitro analysis could be useful for proposing a shape design optimization of sophisticated pediatric ePTFE pulmonary valve.

  16. Towards a Tissue-Engineered Contractile Fontan-Conduit: The Fate of Cardiac Myocytes in the Subpulmonary Circulation.

    Directory of Open Access Journals (Sweden)

    Daniel Biermann

    Full Text Available The long-term outcome of patients with single ventricles improved over time, but remains poor compared to other congenital heart lesions with biventricular circulation. Main cause for this unfavourable outcome is the unphysiological hemodynamic of the Fontan circulation, such as subnormal systemic cardiac output and increased systemic-venous pressure. To overcome this limitation, we are developing the concept of a contractile extracardiac Fontan-tunnel. In this study, we evaluated the survival and structural development of a tissue-engineered conduit under in vivo conditions. Engineered heart tissue was generated from ventricular heart cells of neonatal Wistar rats, fibrinogen and thrombin. Engineered heart tissues started beating around day 8 in vitro and remained contractile in vivo throughout the experiment. After culture for 14 days constructs were implanted around the right superior vena cava of Wistar rats (n = 12. Animals were euthanized after 7, 14, 28 and 56 days postoperatively. Hematoxylin and eosin staining showed cardiomyocytes arranged in thick bundles within the engineered heart tissue-conduit. Immunostaining of sarcomeric actin, alpha-actin and connexin 43 revealed a well -developed cardiac myocyte structure. Magnetic resonance imaging (d14, n = 3 revealed no constriction or stenosis of the superior vena cava by the constructs. Engineered heart tissues survive and contract for extended periods after implantation around the superior vena cava of rats. Generation of larger constructs is warranted to evaluate functional benefits of a contractile Fontan-conduit.

  17. Ceramic fiber blanket wrap for fire protection of cable trays and conduits

    International Nuclear Information System (INIS)

    Chaille, C.E.; Reiman, R.J.

    1980-01-01

    In some areas of nuclear power plants, cables of redundant electrical systems, which are necessary for the safe shutdown of the reactor, are in close proximity. If a fire should occur in one of these areas, both electrical systems could be destroyed before the fire is extinguished and control of the reactor may be lost. A ceramic fiber blanket was evaluated as a fire protective wrap around cable trays and conduits. 2 refs

  18. Adult Stem Cell Based Enhancement of Nerve Conduit for Peripheral Nerve Repair

    Science.gov (United States)

    2016-10-01

    accompanied by injuries to peripheral nerves; if not repaired, the trauma can lead to significant dysfunction and disability . While nerves have the ability to...recovery, minimized disability , and increased quality of life for our wounded warriors. 2. KEYWORDS: Stem Cell, Nerve Conduit, Peripheral Nerve...would be a paradigm shift away from ordering X-rays at 10-12 weeks and only ordering a CT scan. It has the potential to change the standard of care

  19. Age-related changes in biomechanical properties of transgenic porcine pulmonary and aortic conduits

    International Nuclear Information System (INIS)

    Wilczek, Piotr; Malota, Zbigniew; Lesiak, Anna; Niemiec-Cyganek, Aleksandra; Kubin, Barbara; Nozynski, Jerzy; Mzyk, Aldona; Gramatyka, Michalina; Slomski, Ryszard; Wilczek, Grazyna; Opiela, Jolanta

    2014-01-01

    The limitations associated with conventional valve prosthesis have led to a search for alternatives. One potential approach is tissue engineering. Most tissue engineering studies have described the biomechanical properties of heart valves derived from adult pigs. However, because one of the factors affecting the function of valve prosthesis after implantation is appropriate sizing for a given patient, it is important to evaluate the usefulness of a heart valve given the donor animal’s weight and age. The aim of this study was to evaluate how the age of a pig can influence the biomechanical and hemodynamical properties of porcine heart valve prosthesis after acellularization. Acellular porcine aortic and pulmonary valve conduits were used. Hearts were harvested from animals differing in weight and age. The biomechanical properties of the valves were then characterized using a uniaxial tensile test. Moreover, computer simulations based on the finite element method (FEM) were used to study the influence of biomechanical properties on the hemodynamic conditions. Studying biomechanical and morphological changes in porcine heart valve conduits according to the weight and age of the animals can be valuable for developing age-targeted therapy using tissue engineering techniques. (paper)

  20. Field observations of extended seawater intrusion through subsurface karst conduit networks at Wakulla Spring in the Woodville Karst Plain, Florida

    Science.gov (United States)

    Xu, Z.; Bassett, S.; Hu, B. X.; Dyer, S.

    2016-12-01

    Five periods of increased electrical conductivity have been found in the karst conduits supplying one of the largest first magnitude springs in Florida with water. Numerous well-developed conduit networks are distributed in the Woodville Karst Plain (WKP), Florida and connected to the Gulf of Mexico. A composite analysis of precipitation and electric conductivity data provides strong evidence that the increases in conductivity are directly tied to seawater intrusion moving inland and traveling 14 miles against the prevailing regional hydraulic gradient from from Spring Creek Spring Complex (SCSC), a group of submarine springs at the Gulf Coast. A geochemical analysis of samples from the spring vent rules out anthropogenic contamination and upwelling regional recharge from the deep aquifer as sources of the rising conductivity. The interpretation is supported by the conceptual model established by prior researchers working to characterize the study area. This abstract documented the first and longest case of seawater intrusion in the WKP, and also indicates significant possibility of seawater contamination through subsurface conduit networks in a coastal karst aquifer.

  1. Faulting within the Mount St. Helens conduit and implications for volcanic earthquakes

    Science.gov (United States)

    Pallister, John S.; Cashman, Katharine V.; Hagstrum, Jonathan T.; Beeler, Nicholas M.; Moran, Seth C.; Denlinger, Roger P.

    2013-01-01

    The 2004–2008 eruption of Mount St. Helens produced seven dacite spines mantled by cataclastic fault rocks, comprising an outer fault core and an inner damage zone. These fault rocks provide remarkable insights into the mechanical processes that accompany extrusion of degassed magma, insights that are useful in forecasting dome-forming eruptions. The outermost part of the fault core consists of finely comminuted fault gouge that is host to 1- to 3-mm-thick layers of extremely fine-grained slickenside-bearing ultracataclasite. Interior to the fault core, there is an ∼2-m-thick damage zone composed of cataclastic breccia and sheared dacite, and interior to the damage zone, there is massive to flow-banded dacite lava of the spine interior. Structures and microtextures indicate entirely brittle deformation, including rock breakage, tensional dilation, shearing, grain flow, and microfaulting, as well as gas and fluid migration through intergranular pores and fractures in the damage zone. Slickenside lineations and consistent orientations of Riedel shears indicate upward shear of the extruding spines against adjacent conduit wall rocks.Paleomagnetic directions, demagnetization paths, oxide mineralogy, and petrology indicate that cataclasis took place within dacite in a solidified steeply dipping volcanic conduit at temperatures above 500 °C. Low water content of matrix glass is consistent with brittle behavior at these relatively high temperatures, and the presence of tridymite indicates solidification depths of <1 km. Cataclasis was coincident with the eruption’s seismogenic zone at <1.5 km.More than a million small and low-frequency “drumbeat” earthquakes with coda magnitudes (Md) <2.0 and frequencies <5 Hz occurred during the 2004–2008 eruption. Our field data provide a means with which to estimate slip-patch dimensions for shear planes and to compare these with estimates of slip patches based on seismic moments and shear moduli for dacite rock and

  2. Numerical study of groundwater flow cycling controlled by seawater/freshwater interaction in a coastal karst aquifer through conduit network using CFPv2

    Science.gov (United States)

    Xu, Zexuan; Hu, Bill X.; Davis, Hal; Kish, Stephen

    2015-11-01

    In this study, a groundwater flow cycling in a karst springshed and an interaction between two springs, Spring Creek Springs and Wakulla Springs, through a subground conduit network are numerically simulated using CFPv2, the latest research version of MODFLOW-CFP (Conduit Flow Process). The Spring Creek Springs and Wakulla Springs, located in a marine estuary and 11 miles inland, respectively, are two major groundwater discharge spots in the Woodville Karst Plain (WKP), North Florida, USA. A three-phase conceptual model of groundwater flow cycling between the two springs and surface water recharge from a major surface creek (Lost Creek) was proposed in various rainfall conditions. A high permeable subground karst conduit network connecting the two springs was found by tracer tests and cave diving. Flow rate of discharge, salinity, sea level and tide height at Spring Creek Springs could significantly affect groundwater discharge and water stage at Wakulla Springs simultaneously. Based on the conceptual model, a numerical hybrid discrete-continuum groundwater flow model is developed using CFPv2 and calibrated by field measurements. Non-laminar flows in conduits and flow exchange between conduits and porous medium are implemented in the hybrid coupling numerical model. Time-variable salinity and equivalent freshwater head boundary conditions at the submarine spring as well as changing recharges have significant impacts on seawater/freshwater interaction and springs' discharges. The developed numerical model is used to simulate the dynamic hydrological process and quantitatively represent the three-phase conceptual model from June 2007 to June 2010. Simulated results of two springs' discharges match reasonably well to measurements with correlation coefficients 0.891 and 0.866 at Spring Creeks Springs and Wakulla Springs, respectively. The impacts of sea level rise on regional groundwater flow field and relationship between the inland springs and submarine springs are

  3. A pilot muon radiography to image the shallow conduit of the Stromboli volcano: results and future prospects

    Science.gov (United States)

    Miyamoto, Seigo; Tioukov, Valeri; Sirignano, Chiara; Bozza, Cristiano; Morishima, Kunihiro

    2017-04-01

    The test result of imaging the shallow part of the Stromboli crater zone by using cosmic-ray muons in 2012 and possible performance of the future muon observation will be presented. It is well known that the behavior of volcanic eruptions strongly depends on the shape of the conduit. Stromboli is one of the most known and studied active volcanoes in the world, nevertheless the details of its internal structure are not well defined yet. Geophysical exploration method which use high energy cosmic-ray muons and makes the density image of the object like X-ray radiography for the human body is called "muon radiography " or "muography". A pilot muography was done for the shallow part of Stromboli in 2012. We succeeded to clarify that there is a less density part at the North-East cone in the crater zone. It is considered that the stack of volcanic ashes. On the other hand, we also confirmed that the contamination of the physical background particles and they makes the noisy density image especially about 50 meter below from the top of the crater. In another observation, Nishiyama et al (2014) revealed the contents of background particles and the way to remove them were presented. They showed that the main contents of the background particles is low kinetic energy charged particles and also showed that it is possible to remove them by using multi-layerd muon film detector. We can plan the future muography observation to see the deeper part of the conduit( at least until 100 meter from the top of crater) by their backgroundless method. Therefore we estimated possible performance of the future observation by multi-layer muon films. The result suggests that we might get the image of shallow conduit from the surface to the depth of e.g. 55 meter with 20 meter spatial resolution or 100 meter with 27 meter resolution in case the density in the conduit is 0.0 g/cm3 and with 71 percent statistical confidence level.

  4. Brachial artery repair using the basilic vein as a reliable conduit in a 3-year-old child

    Directory of Open Access Journals (Sweden)

    Hyunyoung G. Kim

    2017-04-01

    Full Text Available A supracondylar fracture of the humerus is the most common upper extremity fracture in children with concurrent neurovascular complications. However, bypass grafting in the management of a pediatric open elbow dislocation with an arterial injury has rarely been reported in the literature. Hence, an adequate conduit for a vessel graft interposition remains questionable when a primary anastomosis is limited in an arterial reconstruction. The purpose of this study is to present a brachial artery reconstruction in a 3-year-old patient with an open supracondylar fracture of the humerus. In the clinical and surgical examination of the patient, an open wound in the left antecubital fossa presented with accompanying brachial artery injury. To repair the artery, a reverse end-to-end anastomosis was conducted using basilic vein graft from the ipsilateral arm under general anesthesia. The patient had palpable radial pulses in the postoperative clinical examination and was discharged without complications. The great saphenous vein (GSV has proven to be the most common and the best conduit for arterial reconstruction of the upper extremity in the adult patients. However, the GSV graft is known to have the propensity for becoming aneurysmal in pediatric patients. Some studies have demonstrated the basilic vein as a suitable conduit in pediatric patients, in that it has durable patency, fewer branches, size compatibility for anastomosis, and proximity to the brachial artery. Our case confirms the safety of using this autogenous vein from within the zone of injury for arterial reconstruction, after a supracondylar humeral fracture. The management of pediatric elbow fractures accompanying vascular injuries can be technically demanding due to relatively small, delicate structures and concurrent neurovascular network. Nonetheless, a vascular injury should be treated with high level of suspicion and immediate intervention to avoid any limb ischemia or loss. In

  5. Modified conduit preparation creates a pseudosinus in an aortic valve-sparing procedure for aneurysm of the ascending aorta.

    Science.gov (United States)

    Cochran, R P; Kunzelman, K S; Eddy, A C; Hofer, B O; Verrier, E D

    1995-06-01

    Mechanical valved conduit replacement of the aortic root is a durable and appropriate procedure for many diseases of the ascending aorta, but may sacrifice an anatomically salvageable aortic valve. For young active patients and for patients with "systemic" arterial disease (atherosclerosis, Marfan's syndrome) who may require future operations, life-long anticoagulation with its attendant thromboembolic versus hemorrhagic risks is not ideal. Several techniques have been suggested as aortic valve-sparing options. Recently, a procedure was described that combines the freehand homograft techniques with the standard Bentall techniques (David procedure). This innovative technique replaces the ascending aorta with a Dacron cylinder, spares the aortic valve, and restores competence and thus offers an excellent alternative. The durability of this procedure that places the aortic valve inside a cylindrical conduit without sinuses of Valsalva is unknown. In selected patients, we have used this technique to spare the aortic valve. On the basis of experimental data and preliminary computer modeling, with the hope of improving the durability, we have modified the conduit to create a "pseudosinus" in our most recent nine patients. We have done the David procedure in 10 patients. The pseudosinus modification was done in the most recent nine patients. Patients' ages ranged from 37 to 71 years (mean 49.9 years). There were five female and five male patients. Five patients had Marfan's syndrome and five patients had annuloaortic ectasia. There has been no mortality and all patients have had both early and late follow-up echocardiography. Five patients have zero to trace aortic insufficiency, four patients have trace to mild aortic insufficiency, and one patient has mild or "1+" aortic insufficiency. Aortic insufficiency has not progressed in any patient during the 18 months of follow-up. The patient with 1+ aortic insufficiency has no activity limits, good ventricular function, and

  6. Permeability and 3-D melt geometry in shear-induced high melt fraction conduits

    Science.gov (United States)

    Zhu, W.; Cordonnier, B.; Qi, C.; Kohlstedt, D. L.

    2017-12-01

    Observations of dunite channels in ophiolites and uranium-series disequilibria in mid-ocean ridge basalt suggest that melt transport in the upper mantle beneath mid-ocean ridges is strongly channelized. Formation of high melt fraction conduits could result from mechanical shear, pyroxene dissolution, and lithological partitioning. Deformation experiments (e.g. Holtzman et al., 2003) demonstrate that shear stress causes initially homogeneously distributed melt to segregate into an array of melt-rich bands, flanked by melt-depleted regions. At the same average melt fraction, the permeability of high melt fraction conduits could be orders of magnitude higher than that of their homogenous counterparts. However, it is difficult to determine the permeability of melt-rich bands. Using X-ray synchrotron microtomography, we obtained high-resolution images of 3-dimensional (3-D) melt distribution in a partially molten rock containing shear-induced high melt fraction conduits. Sample CQ0705, an olivine-alkali basalt aggregate with a nominal melt fraction of 4%, was deformed in torsion at a temperature of 1473 K and a confining pressure of 300 MPa to a shear strain of 13.3. A sub-volume of CQ0705 encompassing 3-4 melt-rich bands was imaged. Microtomography data were reduced to binary form so that solid olivine is distinguishable from basalt glass. At a spatial resolution of 160 nm, the 3-D images reveal the shape and connectedness of melt pockets in the melt-rich bands. Thin melt channels formed at grain edges are connected at large melt nodes at grain corners. Initial data analysis shows a clear preferred orientation of melt pockets alignment subparallel to the melt-rich band. We use the experimentally determined geometrical parameters of melt topology to create a digital rock with identical 3-D microstructures. Stokes flow simulations are conducted on the digital rock to obtain the permeability tensor. Using this digital rock physics approach, we determine how deformation

  7. Hot upwelling conduit beneath the Atlas Mountains, Morocco

    Science.gov (United States)

    Sun, Daoyuan; Miller, Meghan S.; Holt, Adam F.; Becker, Thorsten W.

    2014-11-01

    The Atlas Mountains of Morocco display high topography, no deep crustal root, and regions of localized Cenozoic alkaline volcanism. Previous seismic imaging and geophysical studies have implied a hot mantle upwelling as the source of the volcanism and high elevation. However, the existence, shape, and physical properties of an associated mantle anomaly are debated. Here we use seismic waveform analysis from a broadband deployment and geodynamic modeling to define the physical properties and morphology of the anomaly. The imaged low-velocity structure extends to ~200 km beneath the Atlas and appears ~350 K hotter than the ambient mantle with possible partial melting. It includes a lateral conduit, which suggests that the Quaternary volcanism arises from the upper mantle. Moreover, the shape and temperature of the imaged anomaly indicate that the unusually high topography of the Atlas Mountains is due to active mantle support.

  8. Thermal Expansivity Between 150 and 800°C of Hydrothermally Altered Conduit Dyke Samples from USDP-4 Drill Core (Mt Unzen, Shimabara, Japan)

    Science.gov (United States)

    Yilmaz, T. I.; Hess, K. U.; Vasseur, J.; Wadsworth, F. B.; Gilg, H. A.; Nakada, S.; Dingwell, D. B.

    2017-12-01

    When hot magma intrudes the crust, the surrounding rocks expand. Similarly, the cooling magma contracts. The expansion and contraction of these multiphase materials is not simple and often requires empirical constraint. Therefore, we constrained the thermal expansivity of Unzen dome and conduit samples using a NETZSCH® DIL 402C. Following experiments, those samples were scanned using a Phoenix v|tome|x m to observe the cracks that may have developed during the heating and cooling. The dome samples do not show petrological or chemical signs of alteration. However, the alteration of the conduit dykes is represented by the occurrence of the main secondary phases such as chlorite, sulfides, carbonates, R1 (Reichweite parameter) illite-smectite, and kaolinite. These alteration products indicate an (I) early weak to moderate argillic magmatic alteration, and a (II) second stage weak to moderate propylitic hydrothermal alteration. The linear thermal expansion coefficient aL of the dome material is K-1 between 150° and 800°C and shows a sharp peak of up to K-1 around the alpha-beta-quartz-transition ( 573°C). In contrast, aL of the hydrothermally altered conduit samples starts to increase around 180° and reaches K-1 at 400°C. We interpret this effect as being due to the water content of the kaolinite and the R1 illite-smectite, which induces larger expansions per degree temperature change. Furthermore, the altered conduit samples show a more pronounced increases of aL between 500 and 650°C of up to peaks at K-1, which is generated by the breakdown of chlorite, iron-rich dolomite solid solutions, calcite, and pyrite. We use a 1D conductive model of heat transfer to explore how the country rock around the Unzen conduit zone would heat up after intrusion. In turn, we convert these temperature profiles to thermal stress profiles, assuming the edifice is largely undeformable. We show that these high linear thermal expansion coefficients of the hydrothermally altered

  9. Cable-in-conduit conductor optimization for fusion magnet applications

    International Nuclear Information System (INIS)

    Miller, J.R.; Kerns, J.A.

    1987-01-01

    Careful design of the toroidal-field (TF) and poloidal-field (PF) coils in a tokamak machine using cable-in-conduit conductors (CICC) can result in quite high overall winding-pack current densities - even with the high nuclear heat loads that may be imposed in operating a fusion reactor - and thereby help reduce the overall machine size. In our design process, we systematically examined the operational environment of a magnet, e.g., mechanical stresses, current, field, heat load, coolant temperature, and cooldown stresses, to determine the optimum amounts of copper, superconductor, helium, and sheath material for the CICC. This process is being used to design the superconducting magnet systems that comprise the Tokamak Ignition/Burn Experimental Reactor (TIBER II). 13 refs., 2 figs

  10. Hawaiian fissure fountains: Quantifying vent and shallow conduit geometry, episode 1 of the 1969-1974 Mauna Ulu eruption: Chapter 17

    Science.gov (United States)

    Parcheta, Carolyn; Fagents, Sarah; Swanson, Donald A.; Houghton, Bruce F.; Ericksen, Todd; Carey, Rebecca; Cayol, Valérie; Poland, Michael P.; Weis, Dominique

    2015-01-01

    Geometries of shallow magmatic pathways feeding volcanic eruptions are poorly constrained, yet many key interpretations about eruption dynamics depend on knowledge of these geometries. Direct quantification is difficult because vents typically become blocked with lava at the end of eruptions. Indirect geophysical techniques have shed light on some volcanic conduit geometries, but the scales are too coarse to resolve narrow fissures (widths typically 1 m). Kīlauea's Mauna Ulu eruption, which started with 30 m. Direct measurements at the ground surface were augmented by tripod-mounted lidar measurements to quantify the shallow conduit geometry for three vents at a resolution eruptive behavior, especially if incorporated into computer models.

  11. Construction of nerve guide conduits from cellulose/soy protein composite membranes combined with Schwann cells and pyrroloquinoline quinone for the repair of peripheral nerve defect.

    Science.gov (United States)

    Luo, Lihua; Gan, Li; Liu, Yongming; Tian, Weiqun; Tong, Zan; Wang, Xiong; Huselstein, Celine; Chen, Yun

    2015-02-20

    Regeneration and functional reconstruction of peripheral nerve defects remained a significant clinical challenge. Nerve guide conduits, with seed cells or neurotrophic factors (NTFs), had been widely used to improve the repair and regeneration of injured peripheral nerve. Pyrroloquinoline quinone (PQQ) was an antioxidant that can stimulate nerve growth factors (NGFs) synthesis and accelerate the Schwann cells (SCs) proliferation and growth. In present study, three kinds of nerve guide conduits were constructed: one from cellulose/SPI hollow tube (CSC), another from CSC combined with SCs (CSSC), and the third one from CSSC combined with PQQ (CSSPC), respectively. And then they were applied to bridge and repair the sciatic nerve defect in rats, using autograft as control. Effects of different nerve guide conduits on the nerve regeneration were comparatively evaluated by general analysis, sciatic function index (SFI) and histological analysis (HE and TEM). Newly-formed regenerative nerve fibers were observed and running through the transparent nerve guide conduits 12 weeks after surgery. SFI results indicated that the reconstruction of motor function in CSSPC group was better than that in CSSC and CSC groups. HE images from the cross-sections and longitudinal-sections of the harvested regenerative nerve indicated that regenerative nerve fibers had been formed and accompanied with new blood vessels and matrix materials in the conduits. TEM images also showed that lots of fresh myelinated and non-myelinated nerve fibers had been formed. Parts of vacuolar, swollen and abnormal axons occurred in CSC and CSSC groups, while the vacuolization and swell of axons was the least serious in CSSPC group. These results indicated that CSSPC group had the most ability to repair and reconstruct the nerve structure and functions due to the comprehensive contributions from hollow CSC tube, SCs and PQQ. As a result, the CSSPC may have the potential for the applications as nerve guide

  12. Simulation of Microdamage and Evaluation of Remaining Life of Steam Conduit Components from New-Generation Refractory Steel 10Kh9MF-Sh

    Science.gov (United States)

    Gladshtein, V. I.

    2018-03-01

    The effects of microdamage on the remaining life of high-temperature components of steam conduits from high-chromium steel 10Kh9MF-Sh and low-alloy steel 12Kh1M1F are compared. To simulate the microdamage, specimens with a circular notch and different relative diameters are fabricated. Specimens with a notch simulating the highest degree of microdamage and smooth specimens are tested for long-term strength. The coefficient of the remaining life of a conduit is computed for the range of relative damage presenting practical interest.

  13. Numerical study of groundwater flow cycling controlled by seawater/freshwater interaction in a coastal karst aquifer through conduit network using CFPv2.

    Science.gov (United States)

    Xu, Zexuan; Hu, Bill X; Davis, Hal; Kish, Stephen

    2015-11-01

    In this study, a groundwater flow cycling in a karst springshed and an interaction between two springs, Spring Creek Springs and Wakulla Springs, through a subground conduit network are numerically simulated using CFPv2, the latest research version of MODFLOW-CFP (Conduit Flow Process). The Spring Creek Springs and Wakulla Springs, located in a marine estuary and 11 miles inland, respectively, are two major groundwater discharge spots in the Woodville Karst Plain (WKP), North Florida, USA. A three-phase conceptual model of groundwater flow cycling between the two springs and surface water recharge from a major surface creek (Lost Creek) was proposed in various rainfall conditions. A high permeable subground karst conduit network connecting the two springs was found by tracer tests and cave diving. Flow rate of discharge, salinity, sea level and tide height at Spring Creek Springs could significantly affect groundwater discharge and water stage at Wakulla Springs simultaneously. Based on the conceptual model, a numerical hybrid discrete-continuum groundwater flow model is developed using CFPv2 and calibrated by field measurements. Non-laminar flows in conduits and flow exchange between conduits and porous medium are implemented in the hybrid coupling numerical model. Time-variable salinity and equivalent freshwater head boundary conditions at the submarine spring as well as changing recharges have significant impacts on seawater/freshwater interaction and springs' discharges. The developed numerical model is used to simulate the dynamic hydrological process and quantitatively represent the three-phase conceptual model from June 2007 to June 2010. Simulated results of two springs' discharges match reasonably well to measurements with correlation coefficients 0.891 and 0.866 at Spring Creeks Springs and Wakulla Springs, respectively. The impacts of sea level rise on regional groundwater flow field and relationship between the inland springs and submarine springs are

  14. Functional and regenerative effects of local administration of autologous mononuclear bone marrow cells combined with silicone conduit on transected femoral nerve of rabbits.

    Science.gov (United States)

    Trindade, Anelise Bonilla; Schestatsky, Pedro; Torres, Vítor Félix; Gomes, Cristiano; Gianotti, Giordano Cabral; Paz, Ana Helena da Rosa; Terraciano, Paula Barros; Marques, Janete Maria Volpato; Guimarães, Karina Magano; Graça, Dominguita Lühers; Cirne-Lima, Elizabeth Obino; Contesini, Emerson Antonio

    2015-10-01

    The inoculation of cells into injury sites can accelerate and improve the quality of nerve regeneration. This study aimed to evaluate the functional and regenerative effects of mononuclear autologous bone marrow cells (MABMC) combined with silicon conduit grafting in rabbit femoral nerves. Twenty-eight animals were allocated to one of two groups: treatment group (TG) or control group (CG), divided according to the time of evaluation, at either 50 or 75 days. After neurotmesis of the femoral nerve, surgical repair was performed with nerve autografts in silicon conduits, leaving a 5mm gap in both groups. The TG received MABMC in silicon conduits, and CG received a sham saline inoculum. Histological, clinical and electrophysiological analyses detected no differences between groups, but analysis of leg diameter showed that TG diameters were larger. This cell therapy did not improve regeneration of the femoral nerve, but there was a tendency for better functional recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Hydrothermal Alteration of the Mt Unzen Conduit (Shimabara/Japan)

    Science.gov (United States)

    Yilmaz, T. I.; Mayer, K.; Hess, K. U.; Janots, E.; Gilg, H. A.; Dingwell, D. B.

    2016-12-01

    Investigations were carried out on hydrothermally altered coherent dacitic dykes samples from (USDP-4) drill core at Mt Unzen stratovolcano (Shimabara/Japan). XRF, XRD, EMPA, and C-O-isotope analysis led to insights concerning chemistry, mineralogy, and intensity of alteration as well as the origin of carbonate-precipitating fluids. Additionally a textural characterization of the occurring replacement features in the magma conduit zone was performed. The occurrence of the main secondary phases such as chlorite, pyrite, carbonates, and R1 (Reichweite parameter) illite-smectite indicate a weak to moderate propylitic to phyllic hydrothermal alteration. The dacitic samples of the dykes show different hydrothermal alteration features: (i) carbonate pseudomorphs after hornblende as well as core and zonal textures due to replacement of plagioclase by R1 illite-smectite, (ii) colloform banded fracture fillings and fillings in dissolution vugs, and (iii) chlorite and R1 illite-smectite in the groundmass. Carbonates in fractures comprise iron-rich dolomite solid solutions ("ankerite") and calcite. Isotopic values of d13Cvpdb = -4.59 ± 0.6‰ and d18Ovpdb = -21.73 ± 0.5‰ indicate a hydrothermal-magmatic origin for the carbonate formation. The chlorite-carbonate-pyrite index (CCPI) and the Ishikawa alteration index (AI), applied to the investigated samples show significant differences (CCPI=52.7-57.8; AI=36.1-40.6) indicating their different degree of alteration. According to Nakada et al., 2005, the C13 to C16 dykes represent the feeder dyke from the latest eruption (1991-1995) whereas C8 represents an earlier dyke feeder dyke from an older eruption. Weakest conduit alteration, which was obtained in samples C16-1-5 and C13-2-5, correlates with the alteration degree of the pristine dome rocks. Highest CCPI value was determined for sample C14-1-5 and the highest AI value was determined for sample C15-2-6. The degrees of alteration do not indicate highest alteration of the

  16. Magnetic losses and reactance change by the use of metallic conduit in electrical installations; Perdidas magneticas y cambio de reactancia por la tuberia metalica en instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, Eduardo; Castaneda D, Miguel; Castulo A, Roberto; Bratu Serban, Neagu [Universidad Autonoma Metropolitana-Azcapotzalco, Mexico, D. F. (Mexico)

    1996-12-31

    In this paper are presented the results obtained in the measurement of magnetic losses in metallic conduits in electric installations. The losses for parasitic currents and by hysteresis were obtained in different conditions of magnetic density, caused by the net current resulting from the sum of all the currents of all the conductors that travel along the conduit. These currents are named differential currents, and the conditions in which they appear in the electric installations are described. The magnetic induction phenomenon that occurs in metallic conduit is briefly described and the basic concepts that describe it. A theoretical-experimental methodology is offered to quantify the energy losses by parasitic currents and by the metal magnetization in these metallic conduits. At the same time, the impact of these differential currents impact in the reactance of the electric installation is quantified. The obtained results for twelve conduits of different diameters and different wall thickness are shown. A comparison analysis is made with the reported results in a previous article, where the losses were estimated by means of the temperature rise measurement of the metallic wall. [Espanol] En este articulo se presentan los resultados obtenidos en la medicion de perdidas magneticas en tuberias conduit (metalicas) en instalaciones electricas. Las perdidas por corrientes parasitas y por histeresis se obtuvieron para diferentes condiciones de densidad magnetica, provocada por la corriente neta resultante de la suma de las corrientes de todos los conductores que viajan por la tuberia. A estas corrientes se les designa corrientes diferenciales y se describen las condiciones en las que estas aparecen en las instalaciones electricas. Se explica brevemente el fenomeno de induccion magnetica que se presenta en las tuberias metalicas y los conceptos basicos que la describen. Se plantea una metodologia teorico-experiemental para cuantificar las perdidas de energia, por

  17. Magnetic losses and reactance change by the use of metallic conduit in electrical installations; Perdidas magneticas y cambio de reactancia por la tuberia metalica en instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, Eduardo; Castaneda D, Miguel; Castulo A, Roberto; Bratu Serban, Neagu [Universidad Autonoma Metropolitana-Azcapotzalco, Mexico, D. F. (Mexico)

    1997-12-31

    In this paper are presented the results obtained in the measurement of magnetic losses in metallic conduits in electric installations. The losses for parasitic currents and by hysteresis were obtained in different conditions of magnetic density, caused by the net current resulting from the sum of all the currents of all the conductors that travel along the conduit. These currents are named differential currents, and the conditions in which they appear in the electric installations are described. The magnetic induction phenomenon that occurs in metallic conduit is briefly described and the basic concepts that describe it. A theoretical-experimental methodology is offered to quantify the energy losses by parasitic currents and by the metal magnetization in these metallic conduits. At the same time, the impact of these differential currents impact in the reactance of the electric installation is quantified. The obtained results for twelve conduits of different diameters and different wall thickness are shown. A comparison analysis is made with the reported results in a previous article, where the losses were estimated by means of the temperature rise measurement of the metallic wall. [Espanol] En este articulo se presentan los resultados obtenidos en la medicion de perdidas magneticas en tuberias conduit (metalicas) en instalaciones electricas. Las perdidas por corrientes parasitas y por histeresis se obtuvieron para diferentes condiciones de densidad magnetica, provocada por la corriente neta resultante de la suma de las corrientes de todos los conductores que viajan por la tuberia. A estas corrientes se les designa corrientes diferenciales y se describen las condiciones en las que estas aparecen en las instalaciones electricas. Se explica brevemente el fenomeno de induccion magnetica que se presenta en las tuberias metalicas y los conceptos basicos que la describen. Se plantea una metodologia teorico-experiemental para cuantificar las perdidas de energia, por

  18. Injunctions against mere conduit of information protected by copyright

    DEFF Research Database (Denmark)

    Sandfeld Jakobsen, Søren; Petersen, Clement Salung

    2011-01-01

    This paper includes an in-depth analysis of EU law and Scandinavian law on injunctions against internet access providers (IAPs) performing as mere conduit of information protected by copyright. In recent Scandinavian case law, courts have granted preliminary injunctions which have caused IAPs...... to either shut down specific internet connections allegedly used to infringe copyright or to block access to internet content, which allegedly infringed applicable copyright rules. This paper considers some significant legal challenges, which are emerging in the wake of this case law, and which should...... requires rules, which take into due consideration the special aspects related to enforcement of copyright on the internet through IAPs. Secondly, it is shown that the termination of internet connections and the blocking of access to internet content may not support the public policies behind copyright law...

  19. Studying the causes for corrosive destruction of water conduits

    Energy Technology Data Exchange (ETDEWEB)

    Azamatova, F I; Kulinichev, G P; Porubov, I S

    1979-01-01

    Pipes from different oil and gas production administrations were selected for X-ray and metallographic studies of the cause of corrosive destruction. The chemical composition and mechanical properties of the pipe material are presented in tables. The phase composition of the corrosion products was studied by X-rays. The complex structure of the layer made up of the corrosion products was taken into consideration. The studies were conducted in an X-ray diffraction chamber. The obtained results are presented in a table. The metallographic studies showed that a significant corrosive damage of the materials of water conduits occurs as a result of the development of local corrosion processes, caused by the substantive heterogeneity of the structure of the metal, related to the nonuniform distribution of the pearlite because of carbon liquidation.

  20. NECL1 coated PLGA as favorable conduits for repair of injured peripheral nerve

    International Nuclear Information System (INIS)

    Xu, Fuben; Zhang, Kun; Lv, Peizhen; Lu, Rongbin; Zheng, Li; Zhao, Jinmin

    2017-01-01

    Restoration of normal neurological function of transected peripheral nerve challenged regenerative medicine and surgery. Previous studies showed that Nectin-like molecule 1 (NECL1) is one of the important adhesion molecules on the axons and Schwann cells is located along the internodes in direct apposition to NECL1. In this study, we fabricated PLGA membrane pre-coated with NECL1, mimicking the natural axons to enhance the adhesion of Schwann cells. Investigation of the cellular response in vitro was performed by detecting cytotoxicity, proliferation, morphology, viability, specific markers and Scanning Electron Microscopy (SEM) of Schwann cells cultured in PLGA. Further, the NECL1-coated PLGA conduits were used for peripheral nerve repair after sciatic nerve defect was constructed. Results showed that PLGA-coated NECL1 enhanced cell proliferation compared with PLGA, as evidenced by MTT analysis, cell viability assay and histological evaluation. RT-PCR results showed that GDNF (glial cell line-derived neurotrophic factor), BDNF (brain-derived neurotrophic factor), CNTF (ciliary neurotrophic factor) and neurotrophic factors of axonal regeneration were highly expressed in PLGA/NECL1 group. S100, which is Schwann cell marker, was also elevated in PLGA-NCEL1 in both mRNA and protein expression as demonstrated by PCR and immunohistochemical examination. Moreover, in vivo study showed that implantation of PLGA/NCEL1 tubes in bridging the nerve defect can significantly improve Schwann cell aggregation and attachment and greatly enhance the functional recovery of nerve regeneration as compared with control and PLGA groups. Therefore, the novel blend of PLGA/NECL1 conduits proved to be promising candidate for tissue engineering scaffold. - Highlights: • A fabricated PLGA tubes pre-coated with Nectin-like molecule 1 (NECL1) strategy for sciatic nerve regeneration is proposed. • The NECL1 coated PLGA can promote Schwann cells adhesion and growth meanwhile maintain the

  1. The efficacy of a scaffold-free Bio 3D conduit developed from human fibroblasts on peripheral nerve regeneration in a rat sciatic nerve model.

    Directory of Open Access Journals (Sweden)

    Hirofumi Yurie

    Full Text Available Although autologous nerve grafting is the gold standard treatment of peripheral nerve injuries, several alternative methods have been developed, including nerve conduits that use supportive cells. However, the seeding efficacy and viability of supportive cells injected in nerve grafts remain unclear. Here, we focused on a novel completely biological, tissue-engineered, scaffold-free conduit.We developed six scaffold-free conduits from human normal dermal fibroblasts using a Bio 3D Printer. Twelve adult male rats with immune deficiency underwent mid-thigh-level transection of the right sciatic nerve. The resulting 5-mm nerve gap was bridged using 8-mm Bio 3D conduits (Bio 3D group, n = 6 and silicone tube (silicone group, n = 6. Several assessments were conducted to examine nerve regeneration eight weeks post-surgery.Kinematic analysis revealed that the toe angle to the metatarsal bone at the final segment of the swing phase was significantly higher in the Bio 3D group than the silicone group (-35.78 ± 10.68 versus -62.48 ± 6.15, respectively; p < 0.01. Electrophysiological studies revealed significantly higher compound muscle action potential in the Bio 3D group than the silicone group (53.60 ± 26.36% versus 2.93 ± 1.84%; p < 0.01. Histological and morphological studies revealed neural cell expression in all regions of the regenerated nerves and the presence of many well-myelinated axons in the Bio 3D group. The wet muscle weight of the tibialis anterior muscle was significantly higher in the Bio 3D group than the silicone group (0.544 ± 0.063 versus 0.396 ± 0.031, respectively; p < 0.01.We confirmed that scaffold-free Bio 3D conduits composed entirely of fibroblast cells promote nerve regeneration in a rat sciatic nerve model.

  2. Large-area irradiated low-level laser effect in a biodegradable nerve guide conduit on neural regeneration of peripheral nerve injury in rats.

    Science.gov (United States)

    Shen, Chiung-Chyi; Yang, Yi-Chin; Liu, Bai-Shuan

    2011-08-01

    This study used a biodegradable composite containing genipin-cross-linked gelatin annexed with β-tricalcium phosphate ceramic particles (genipin-gelatin-tricalcium phosphate, GGT), developed in a previous study, as a nerve guide conduit. The aim of this study was to analyse the influence of a large-area irradiated aluminium-gallium-indium phosphide (AlGaInP) diode laser (660 nm) on the neural regeneration of the transected sciatic nerve after bridging the GGT nerve guide conduit in rats. The animals were divided into two groups: group 1 comprised sham-irradiated controls and group 2 rats underwent low-level laser (LLL) therapy. A compact multi-cluster laser system with 20 AlGaInP laser diodes (output power, 50mW) was applied transcutaneously to the injured peripheral nerve immediately after closing the wound, which was repeated daily for 5 min for 21 consecutive days. Eight weeks after implantation, walking track analysis showed a significantly higher sciatic function index (SFI) score (Pguide conduit in rats. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Conduit degassing and thermal controls on eruption styles at Mount St. Helens

    Science.gov (United States)

    Schneider, Andrew; Rempel, Alan W.; Cashman, Katharine V.

    2012-12-01

    The explosivity of silicic eruptions depends on the interplay between magma rheology, exsolution kinetics, and degassing. Magma degassing is governed by the competing effects of vertical transport within the conduit and the lateral flux of gas out of the conduit (Diller et al., 2006; Jaupart and Allegre, 1991). We combine a simplified treatment of these degassing processes with thermodynamic modeling to examine the conditions present at Mount St. Helens during the spine extruding eruption from 2004 to 2008. We find that two parameters are primarily responsible for controlling the eruptive style: the magma chamber temperature, and a dimensionless parameter that gauges the efficiency of lateral degassing. Together, these parameters determine whether and where magma can solidify at depth to form a dense solid plug that is gradually extruded as a volcanic spine. We show that the small (50 oC) decrease in magma chamber temperature between eruptive activity in the 1980s and that of 2004-2008, combined with a modest increase in degassing efficiency associated with lower volumetric flux, can explain the observed change in erupted material from viscous lava flows to solidified spines. More generally, we suggest that similar threshold behavior may explain observed abrupt transitions in effusive eruptive styles at other intermediate composition volcanoes. Finally, we extrapolate our results to suggest that the increase in degassing efficiency accompanying decreasing magma supply rates may have caused the transition from explosive to effusive activity in late 1980.

  4. Flow-rate measurements in closed-conduits by tracer techniques

    International Nuclear Information System (INIS)

    Lund Plantat, C.

    1982-01-01

    This paper presents the study of the precision obtained measuring flow-rates in closed-conduits by tracer techniques. The flow-rates analyzed were in the range of 10 to 20 l/s and Reynolds numbers from 10 5 to 2 x 10 5 . Tracer used were fluoresceine and In-113 m; and the measurements were performed with the dilution method (punctual and continuous injection) and the Allen method. Precisions for the method of punctual and continuous injections were 6.25% and 9.45% for fluoresceine and 9.3% and 3% for In-113, respectively. For Allen method with In-113 m a precision of 5% was obtained; probably this value was affected by the short distance between detectors. In all cases the error corresponds with the expected value except in one measurement at a 68.3% confidence level. (I.V.)

  5. Bronchovascular reconstruction with a bovine pericardial conduit and surgical reintervention due to thrombosis with revascularisation.

    Science.gov (United States)

    Peña, Emilio; Blanco, Montserrat; Otero, Teresa

    2014-01-01

    We present the case of a 57-year-old male with left hilar squamous cell carcinoma infiltrating the pulmonary artery and in whom a sleeve bronchoplasty and angioplasty were performed using a bovine pericardial conduit. Three days post-operatively, graft thrombosis was detected; thrombectomy and graft reconstruction were performed with revascularisation of the graft. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  6. [Electrophysiological study on rat conduit pulmonary artery smooth muscle cells under normoxia and acute hypoxia].

    Science.gov (United States)

    Hu, Ying; Zou, Fei; Cai, Chun-Qing; Wu, Hang-Yu; Yun, Hai-Xia; Chen, Yun-Tian; Jin, Guo-En; Ge, Ri-Li

    2006-10-25

    The present study was designed to investigate the electrophysiological characteristics of rat conduit pulmonary artery smooth muscle cells (PASMCs) and the response to acute hypoxia. PASMCs of the 1st to 2nd order branches in the conduit pulmonary arteries were obtained by enzymatic isolation. The PASMCs were divided into acute hypoxia preconditioned group and normoxia group. Hypoxia solutions were achieved by bubbling with 5% CO2 plus 95% N2 for at least 30 min before cell perfusion. Potassium currents were compared between these two groups using whole-cell patch clamp technique. The total outward current of PASMCs was measured under normoxia condition when iBTX [specific blocking agent of large conductance Ca-activated K(+) (BK(Ca)) channel] and 4-AP [specific blocking agent of delayed rectifier K(+) (K(DR)) channel] were added consequently into bath solution. PASMCs were classified into three types according to their size, shape and electrophysiological characteristics. Type I cells are the smallest with spindle shape, smooth surface and discrete perinuclear bulge. Type II cells show the biggest size with banana-like appearance. Type III cells have the similar size with type I, and present intermediary shape between type I and type II. iBTX had little effect on the total outward current in type I cells, while 4-AP almost completely blocked it. Most of the total outward current in type II cells was inhibited by iBTX, and the remaining was sensitive to 4-AP. In type III cells, the total outward current was sensitive to both iBTX and 4-AP. Acute hypoxia reduced the current in all three types of cells: (1614.8+/-62.5) pA to (892.4+/-33.6) pA for type I cells (Ppotassium current and improves the E(m) in PASMCs. These effects may be involved in the modulation of constriction/relaxation of conduit artery under acute hypoxia. Different distribution of K(DR) and BK(Ca) channels in these three types of PASMCs might account for their different constriction

  7. Le projet de recherche: définition, conduite et réalisation

    OpenAIRE

    Stockinger , Peter

    2013-01-01

    Master; Ce support de séminaire développe brièvement les quatre points suivants: 1) Définition d’un projet de recherche – présentation générale et recommandations. 2) La conduite d’un projet de recherche – présentation générale et recommandations. 3) La réalisation d’un projet de recherche sous forme d’un mémoire - présentation générale et recommandations. 4) Des ressources pour conduire un projet de recherche : ressources enligne et références bibliographiques.

  8. Biodegradable chitin conduit tubulation combined with bone marrow mesenchymal stem cell transplantation for treatment of spinal cord injury by reducing glial scar and cavity formation

    Directory of Open Access Journals (Sweden)

    Feng Xue

    2015-01-01

    Full Text Available We examined the restorative effect of modified biodegradable chitin conduits in combination with bone marrow mesenchymal stem cell transplantation after right spinal cord hemisection injury. Immunohistochemical staining revealed that biological conduit sleeve bridging reduced glial scar formation and spinal muscular atrophy after spinal cord hemisection. Bone marrow mesenchymal stem cells survived and proliferated after transplantation in vivo, and differentiated into cells double-positive for S100 (Schwann cell marker and glial fibrillary acidic protein (glial cell marker at 8 weeks. Retrograde tracing showed that more nerve fibers had grown through the injured spinal cord at 14 weeks after combination therapy than either treatment alone. Our findings indicate that a biological conduit combined with bone marrow mesenchymal stem cell transplantation effectively prevented scar formation and provided a favorable local microenvironment for the proliferation, migration and differentiation of bone marrow mesenchymal stem cells in the spinal cord, thus promoting restoration following spinal cord hemisection injury.

  9. Biodegradable chitin conduit tubulation combined with bone marrow mesenchymal stem cell transplantation for treatment of spinal cord injury by reducing glial scar and cavity formation

    Science.gov (United States)

    Xue, Feng; Wu, Er-jun; Zhang, Pei-xun; Li-ya, A; Kou, Yu-hui; Yin, Xiao-feng; Han, Na

    2015-01-01

    We examined the restorative effect of modified biodegradable chitin conduits in combination with bone marrow mesenchymal stem cell transplantation after right spinal cord hemisection injury. Immunohistochemical staining revealed that biological conduit sleeve bridging reduced glial scar formation and spinal muscular atrophy after spinal cord hemisection. Bone marrow mesenchymal stem cells survived and proliferated after transplantation in vivo, and differentiated into cells double-positive for S100 (Schwann cell marker) and glial fibrillary acidic protein (glial cell marker) at 8 weeks. Retrograde tracing showed that more nerve fibers had grown through the injured spinal cord at 14 weeks after combination therapy than either treatment alone. Our findings indicate that a biological conduit combined with bone marrow mesenchymal stem cell transplantation effectively prevented scar formation and provided a favorable local microenvironment for the proliferation, migration and differentiation of bone marrow mesenchymal stem cells in the spinal cord, thus promoting restoration following spinal cord hemisection injury. PMID:25788929

  10. Experimental sintering of ash at conduit conditions and implications for the longevity of tuffisites

    Science.gov (United States)

    Gardner, James E.; Wadsworth, Fabian B.; Llewellin, Edward W.; Watkins, James M.; Coumans, Jason P.

    2018-03-01

    Escape of gas from magma in the conduit plays a crucial role in mitigating explosivity. Tuffisite veins—ash-filled cracks that form in and around volcanic conduits—represent important gas escape pathways. Sintering of the ash infill decreases its porosity, eventually forming dense glass that is impermeable to gas. We present an experimental investigation of surface tension-driven sintering and associated densification of rhyolitic ash under shallow conduit conditions. Suites of isothermal (700-800 °C) and isobaric H2O pressure (20 and 40 MPa) experiments were run for durations of 5-90 min. Obsidian powders with two different size distributions were used: 1-1600 μm (mean size = 89 μm), and 63-400 μm (mean size = 185 μm). All samples evolved similarly through four textural phases: phase 1—loose and cohesion-less particles; phase 2—particles sintered at contacts and surrounded by fully connected tortuous pore space of up to 40% porosity; phase 3—continuous matrix of partially coalesced particles that contain both isolated spherical vesicles and connected networks of larger, contorted vesicles; phase 4—dense glass with 2-5% fully isolated vesicles that are mainly spherical. Textures evolve faster at higher temperature and higher H2O pressure. Coarse samples sinter more slowly and contain fewer, larger vesicles when fully sintered. We quantify the sintering progress by measuring porosity as a function of experimental run-time, and find an excellent collapse of data when run-time is normalized by the sintering timescale {λ}_s=η \\overline{R}/σ , where η is melt viscosity, \\overline{R} is mean particle radius, and σ is melt-gas surface tension. Because timescales of diffusive H2O equilibration are generally fast compared to those of sintering, the relevant melt viscosity is calculated from the solubility H2O content at experimental temperature and pressure. We use our results to develop a framework for estimating ash sintering rates under shallow

  11. Theory and modelling of quench in cable-in-conduit superconducting magnets

    International Nuclear Information System (INIS)

    Shajii, A.

    1994-04-01

    A new simple, self consistent theoretical model is presented that describes the phenomena of quench propagation in Cable-In-Conduit superconducting magnets. The model (Quencher) circumvents many of the difficulties associated with obtaining numerical solutions in more general existing models. Specifically, a factor of 30-50 is gained in CPU time over the general, explicit time dependent codes used to study typical quench events. The corresponding numerical implementation of the new model is described and the numerical results are shown to agree very well with those of the more general models, as well as with experimental data. Further, well justified approximations lead to the MacQuench model that is shown to be very accurate and considerably more efficient than the Quencher model. The MacQuench code is suitable for performing quench studies on a personal computer, requiring only several minutes of CPU time. In order to perform parametric studies on new conductor designs it is required to utilize a model such as MacQuench because of the high computational efficiency of this model. Finally, a set of analytic solutions for the problem of quench propagation in Cable-In-Conduit Conductors is presented. These analytic solutions represent the first such results that remain valid for the long time scales of interest during a quench process. The assumptions and the resulting simplifications that lead to the analytic solutions are discussed, and the regimes of validity of the various approximations are specified. The predictions of the analytic results are shown to be in very good agreement with numerical as well as experimental results. Important analytic scaling relations are verified by such comparisons, and the consequences of some of these scalings on currently designed superconducting magnets are discussed

  12. Tissue-engineered spiral nerve guidance conduit for peripheral nerve regeneration.

    Science.gov (United States)

    Chang, Wei; Shah, Munish B; Lee, Paul; Yu, Xiaojun

    2018-06-01

    Recently in peripheral nerve regeneration, preclinical studies have shown that the use of nerve guidance conduits (NGCs) with multiple longitudinally channels and intra-luminal topography enhance the functional outcomes when bridging a nerve gap caused by traumatic injury. These features not only provide guidance cues for regenerating nerve, but also become the essential approaches for developing a novel NGC. In this study, a novel spiral NGC with aligned nanofibers and wrapped with an outer nanofibrous tube was first developed and investigated. Using the common rat sciatic 10-mm nerve defect model, the in vivo study showed that a novel spiral NGC (with and without inner nanofibers) increased the successful rate of nerve regeneration after 6 weeks recovery. Substantial improvements in nerve regeneration were achieved by combining the spiral NGC with inner nanofibers and outer nanofibrous tube, based on the results of walking track analysis, electrophysiology, nerve histological assessment, and gastrocnemius muscle measurement. This demonstrated that the novel spiral NGC with inner aligned nanofibers and wrapped with an outer nanofibrous tube provided a better environment for peripheral nerve regeneration than standard tubular NGCs. Results from this study will benefit for future NGC design to optimize tissue-engineering strategies for peripheral nerve regeneration. We developed a novel spiral nerve guidance conduit (NGC) with coated aligned nanofibers. The spiral structure increases surface area by 4.5 fold relative to a tubular NGC. Furthermore, the aligned nanofibers was coated on the spiral walls, providing cues for guiding neurite extension. Finally, the outside of spiral NGC was wrapped with randomly nanofibers to enhance mechanical strength that can stabilize the spiral NGC. Our nerve histological data have shown that the spiral NGC had 50% more myelinated axons than a tubular structure for nerve regeneration across a 10 mm gap in a rat sciatic nerve

  13. Investigating the influence of conduit residues on polyurethane plates

    Directory of Open Access Journals (Sweden)

    Rachel Faverzani Magnago

    Full Text Available Abstract Converting waste into a product similar to the original one or into another useful product is to save energy, protect natural resources, and bring back to the production cycle what was discarded. In that direction, new polyurethane-based composites have been developed by incorporating 5%, 10%, 15%, and 20% PVC conduit discarded by the construction industry. The objective of this study was to investigate the interaction between the phases of waste incorporation and the effect upon the new material properties. The samples were produced by the polycondensation process. Microstructural analysis revealed a reduction in pore size across the polymer matrix. However, there were no changes in thermal insulation, water absorption, compressive strength, and burning rate tests and in the thermogravimetric analysis and differential scanning calorimetry. The results from this study showed that the replacement of raw material by waste did not affect its properties.

  14. The effect on stability and thermal hydraulic quenchback of perforating the jacket of a cable-in-conduit conductor

    International Nuclear Information System (INIS)

    Dresner, L.

    1994-01-01

    This Paper continues earlier work on the reduction of the quench pressure in a doubler cable-in-conduit conductor achieved by perforating the inner jacket. The present study examines the effect of the perforations on the stability margin and on the ononset of thermal hydraulic quenchback

  15. Fast evolving conduits in clay-bonded sandstone: Characterization, erosion processes and significance for the origin of sandstone landforms

    Czech Academy of Sciences Publication Activity Database

    Bruthans, J.; Svetlik, D.; Soukup, J.; Schweigstillová, Jana; Válek, Jan; Sedláčková, M.; Mayo, A.L.

    2012-01-01

    Roč. 177, December (2012), s. 178-193 ISSN 0169-555X R&D Projects: GA AV ČR IAA300130806 Institutional support: RVO:67985891 ; RVO:68378297 Keywords : sandstone * erosion * piping * tensile strength * conduit * landform Subject RIV: DA - Hydrology ; Limnology Impact factor: 2.552, year: 2012

  16. Utilização de valvas homólogas e heterólogas em condutos extracardíacos The use of homograph and heterograph valves in extracardiac conduits

    Directory of Open Access Journals (Sweden)

    Rui Siqueira de Almeida

    1988-08-01

    Full Text Available O conceito do uso de um conduto extracardíaco para estabelecer uma via de saída, conectando o ventrículo direito com o tronco pulmonar, ou seus ramos, foi desenvolvido na década de 60. Entre 1971 e 1986, 335 pacientes receberam, no The Hospital for Sick Children, de Londres, condutos extracardíacos para o lado direito do coração; 176 destes foram homoenxertos aórticos, preservados em solução antibióticonutriente; 140 heteroenxertos (Hancock, Ross, Carpentier-Edwards, lonescu-Shiley e 19 tubos não valvulados. Estes condutos foram usados na correção de defeitos cardíacos complexos. A idade média foi de 6,34 anos e o peso médio, de 17,8 kg. O diâmetro interno dos condutos variou de 8 a 30 mm. A mortalidade hospitalar foi de 29,2% e o seguimento dos sobrevivente teve uma duração máxima de 14,3 anos, sendo que apenas 40% delas foram relacionadas ao conduto extracardíaco. A curva atuarial, livre de obstrução, dos condutos extracardíacos foi significativa, quando se analisaram os homoenxertos, face a cada grupo de heteroenxertos (p The concept of using extracardiac conduits, to establish an outflow tract between the right ventricle and the pulmonary artery was developed on the sixties. Between 1971 and 1986, 335 patients received extracardiac conduits for the right heart, at The Hospital for Sick Children, London; 176 were antibiotic preserved aortic homografts (Hancock, Ross, Carpentier-Edwards, lonescu-Shiley and 19 non-valved tubes. These conduits were used for the repair of complex congenital heart defects. The mean age of these groups was 6.34 ± 4.6 years and the mean weight 17.8 ± 10.8 kg. The internal diameter of the conduits varied from 8 to 30 mm. The hospital mortality was 29.2% and long-term follow-up of the survivals had a maximum period of 14,39 years. Sixty patients (17.9% were submited to 60 reoperations, being only 40% conduit related. The actuarial survival cun/e of freedom from obstruction was significant

  17. Impact of asymmetric lamp positioning on the performance of a closed-conduit UV reactor

    Directory of Open Access Journals (Sweden)

    Tipu Sultan

    2017-06-01

    Full Text Available Computational fluid dynamics (CFD analyses for the performance improvement of a closed-conduit ultraviolet (UV reactor were performed by changing the lamp positions from symmetric to asymmetric. The asymmetric lamp positioning can be useful for UV reactor design and optimization. This goal was achieved by incorporating the two performance factors, namely reduction equivalent dose (RED and system dose performance. Four cases were carried out for asymmetric lamp positioning within the UV reactor chamber and each case consisted of four UV lamps that were simulated once symmetrically and four times asymmetrically. The results of the four asymmetric cases were compared with the symmetric one. Moreover, these results were evaluated by using CFD simulations of a closed-conduit UV reactor. The fluence rate model, UVCalc3D was employed to validate the simulations results. The simulation results provide detailed information about the dose distribution, pathogen track modeling and RED. The RED value was increased by approximately 15% by using UVCalc3D fluence rate model. Additionally, the asymmetric lamp positioning of the UV lamps had more than 50% of the pathogens received a better and a higher UV dose than in the symmetric case. Consequently, the system dose performance was improved by asymmetric lamp positioning. It was concluded that the performance parameters (higher RED and system dose performance were improved by using asymmetric lamp positioning.

  18. Pulmonary artery reconstruction with a tailor-made bovine pericardial conduit following sleeve resection of a long segmental pulmonary artery for the treatment of lung cancer: technical details of the dog-ear method for adjusting diameter during vascular anastomosis.

    Science.gov (United States)

    Shimizu, Kimihiro; Nagashima, Toshiteru; Ohtaki, Yoichi; Takahashi, Toru; Mogi, Akira; Kuwano, Hiroyuki

    2017-05-01

    Sleeve resection of the pulmonary artery (PA) is always required for lung-sparing operations in which half or more of the vessel circumference is infiltrated by the primary tumor or metastatic hilar nodes. Following sleeve resection, conduit reconstruction may be indicated if there is excessive distance between the two vascular stumps, because there is a high degree of tension when repaired by direct anastomosis. We herein present a case of PA reconstruction using a tailor-made bovine pericardial conduit after sleeve resection of PA during lung cancer surgery. The length of resection was longer than 3 cm, and the difference in diameter between the conduit and peripheral PA stump was larger than 0.5 cm. We describe the surgical and oncological merits of a bovine pericardial conduit, and provide details of our reconstruction technique, focusing on adjustment of diameter between the conduit and peripheral PA (dog-ear method).

  19. Development and fabrication of superconducting hybrid Cable-In-Conduit-Conductor (CICC) for indigenous fusion programme

    International Nuclear Information System (INIS)

    Singh, A.K.; Hussain, M.M.; Abdulla, K.K.; Singh, R.P.

    2011-01-01

    The Atomic Fuels Division has initiated development and fabrication of Cable-In-Conduit-Conductor (CICC) of various configurations, for superconducting fusion grade magnets required for their indigenous Fusion Programme. The process involves development of high grade superconducting multifilamentary wire, multi stage cabling of superconducting as well as copper wires and, finally, jacketing of the cables in SS316LN tubes. The overview of the development and fabrication of CICC is presented in this article. (author)

  20. Distilling allometric and environmental information from time series of conduit size: the standardization issue and its relationship to tree hydraulic architecture.

    Science.gov (United States)

    Carrer, Marco; von Arx, Georg; Castagneri, Daniele; Petit, Giai

    2015-01-01

    Trees are among the best natural archives of past environmental information. Xylem anatomy preserves information related to tree allometry and ecophysiological performance, which is not available from the more customary ring-width or wood-density proxy parameters. Recent technological advances make tree-ring anatomy very attractive because time frames of many centuries can now be covered. This calls for the proper treatment of time series of xylem anatomical attributes. In this article, we synthesize current knowledge on the biophysical and physiological mechanisms influencing the short- to long-term variation in the most widely used wood-anatomical feature, namely conduit size. We also clarify the strong mechanistic link between conduit-lumen size, tree hydraulic architecture and height growth. Among the key consequences of these biophysical constraints is the pervasive, increasing trend of conduit size during ontogeny. Such knowledge is required to process time series of anatomical parameters correctly in order to obtain the information of interest. An appropriate standardization procedure is fundamental when analysing long tree-ring-related chronologies. When dealing with wood-anatomical parameters, this is even more critical. Only an interdisciplinary approach involving ecophysiology, wood anatomy and dendrochronology will help to distill the valuable information about tree height growth and past environmental variability correctly. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Hydraulic analysis of harmonic pumping tests in frequency and time domains for identifying the conduits networks in a karstic aquifer

    Science.gov (United States)

    Fischer, P.; Jardani, A.; Cardiff, M.; Lecoq, N.; Jourde, H.

    2018-04-01

    In a karstic field, the flow paths are very complex as they globally follow the conduit network. The responses generated from an investigation in this type of aquifer can be spatially highly variable. Therefore, the aim of the investigation in this case is to define a degree of connectivity between points of the field, in order to understand these flow paths. Harmonic pumping tests represent a possible investigation method for characterizing the subsurface flow of groundwater. They have several advantages compared to a constant-rate pumping (more signal possibilities, ease of extracting the signal in the responses and possibility of closed loop investigation). We show in this work that interpreting the responses from a harmonic pumping test is very useful for delineating a degree of connectivity between measurement points. We have firstly studied the amplitude and phase offset of responses from a harmonic pumping test in a theoretical synthetic modeling case in order to define a qualitative interpretation method in the time and frequency domains. Three different type of responses have been separated: a conduit connectivity response, a matrix connectivity, and a dual connectivity (response of a point in the matrix, but close to a conduit). We have then applied this method to measured responses at a field research site. Our interpretation method permits a quick and easy reconstruction of the main flow paths, and the whole set of field responses appear to give a similar range of responses to those seen in the theoretical synthetic case.

  2. Quench detection by fluid dynamic means in cable-in-conduit superconductors

    International Nuclear Information System (INIS)

    Dresner, L.

    1988-01-01

    The tight confinement of the helium in cable-in-conduit superconductors creates protection problems because of the pressure rise that can occur during a quench. But the same pressure rise offers the possibility of a non-electrical means of detecting incipient quenches by monitoring the outflow from the various hydraulic paths of the magnet. If the method is to work, the signal must be large enough to be detected unambiguously at an early time, and must not depend too strongly on the length, Joule power density, or rate of growth of the initial normal zone. This paper explores by calculation the degree to which these conditions can be met. The Westinghouse Large Coil Task coil is used as an example

  3. Assessing lateral flows and solute transport during floods in a conduit-flow-dominated karst system using the inverse problem for the advection-diffusion equation

    Science.gov (United States)

    Cholet, Cybèle; Charlier, Jean-Baptiste; Moussa, Roger; Steinmann, Marc; Denimal, Sophie

    2017-07-01

    The aim of this study is to present a framework that provides new ways to characterize the spatio-temporal variability of lateral exchanges for water flow and solute transport in a karst conduit network during flood events, treating both the diffusive wave equation and the advection-diffusion equation with the same mathematical approach, assuming uniform lateral flow and solute transport. A solution to the inverse problem for the advection-diffusion equations is then applied to data from two successive gauging stations to simulate flows and solute exchange dynamics after recharge. The study site is the karst conduit network of the Fourbanne aquifer in the French Jura Mountains, which includes two reaches characterizing the network from sinkhole to cave stream to the spring. The model is applied, after separation of the base from the flood components, on discharge and total dissolved solids (TDSs) in order to assess lateral flows and solute concentrations and compare them to help identify water origin. The results showed various lateral contributions in space - between the two reaches located in the unsaturated zone (R1), and in the zone that is both unsaturated and saturated (R2) - as well as in time, according to hydrological conditions. Globally, the two reaches show a distinct response to flood routing, with important lateral inflows on R1 and large outflows on R2. By combining these results with solute exchanges and the analysis of flood routing parameters distribution, we showed that lateral inflows on R1 are the addition of diffuse infiltration (observed whatever the hydrological conditions) and localized infiltration in the secondary conduit network (tributaries) in the unsaturated zone, except in extreme dry periods. On R2, despite inflows on the base component, lateral outflows are observed during floods. This pattern was attributed to the concept of reversal flows of conduit-matrix exchanges, inducing a complex water mixing effect in the saturated zone

  4. Measurement of nanosize etched pits in SiO2 optical fiber conduit using AFM

    International Nuclear Information System (INIS)

    Espinosa, G.; Golzarri, J.I.; Vazquez, C.; Fragoso, R.

    2003-01-01

    Fission fragment tracks from 252 Cf have been observed in SiO 2 optical fiber, using an atomic force microscope (AFM), after a very short chemical etching in hydrofluoric acid solution at normal temperature. The nuclear track starting and evolution process is followed by the AFM direct measurements on the material surface and beyond a fine layer of the surface material. The images of the scanned cones were determined observing the two predominant energies from 252 Cf fission fragments and the development of the tracks in the 150 μm diameter optical fiber conduit

  5. Clinical experience with an alloplastic stoma prosthesis (Biocarbon) for urinary conduits and cutaneous ureterostomy.

    Science.gov (United States)

    Månsson, W; Harzmann, R

    1988-01-01

    An alloplastic stoma prosthesis, Biocarbon, composed of 99.9% pure carbon in vitreous form, was used in six patients with conduit urinary diversion and in seven with cutaneous ureterostomy. The patients were thereafter observed for 2-86 months. Complications were subcutaneous infection, urinary fistula and ureteral stenosis, which necessitated removal of the prosthesis in most cases. The permanent stoma, without need for adhesive collecting device, was appreciated by the patients. Problems relating to biocompatibility remain to be solved before the place of the stoma prosthesis in urinary diversion can be determined.

  6. Functional collagen conduits combined with human mesenchymal stem cells promote regeneration after sciatic nerve transection in dogs.

    Science.gov (United States)

    Cui, Yi; Yao, Yao; Zhao, Yannan; Xiao, Zhifeng; Cao, Zongfu; Han, Sufang; Li, Xing; Huan, Yong; Pan, Juli; Dai, Jianwu

    2018-05-01

    Numerous studies have focused on the development of novel and innovative approaches for the treatment of peripheral nerve injury using artificial nerve guide conduits. In this study, we attempted to bridge 3.5-cm defects of the sciatic nerve with a longitudinally oriented collagen conduit (LOCC) loaded with human umbilical cord mesenchymal stem cells (hUC-MSCs). The LOCC contains a bundle of longitudinally aligned collagenous fibres enclosed in a hollow collagen tube. Our previous studies showed that an LOCC combined with neurotrophic factors enhances peripheral nerve regeneration. However, it remained unknown whether an LOCC seeded with hUC-MSCs could also promote regeneration. In this study, using various histological and electrophysiological analyses, we found that an LOCC provides mechanical support to newly growing nerves and functions as a structural scaffold for cells, thereby stimulating sciatic nerve regeneration. The LOCC and hUC-MSCs synergistically promoted regeneration and improved the functional recovery in a dog model of sciatic nerve injury. Therefore, the combined use of an LOCC and hUC-MSCs might have therapeutic potential for the treatment of peripheral nerve injury. Copyright © 2018 John Wiley & Sons, Ltd.

  7. Magma shearing and friction in the volcanic conduit: A crystal constraint

    Science.gov (United States)

    Wallace, P. A.; Kendrick, J. E.; Henton De Angelis, S.; Ashworth, J. D.; Coats, R.; Miwa, T.; Mariani, E.; Lavallée, Y.

    2017-12-01

    Magma shearing and friction processes in the shallow volcanic conduit are typical manifestations of strain localisation, which in turn can have an influential role on magma ascent dynamics. The thermal consequences of such events could drive the destabilisation of magma and thus dictate the style of activity at the surface. Shear heating and fault friction are prime candidates for the generation of significant quantities of heat. Here we use a combination of field and experimental evidence to investigate how crystals can act as sensitive recorders of both physical and chemical processes occurring in the shallow volcanic conduit. Spine extrusion during the closing of the 1991-95 eruption at Unzen volcano, Japan, provided the unique opportunity to investigate marginal shear zone formation, which preserves a relic of the deformation during magma ascent. Our results show that crystals can effectively act as a deformation marker during magma ascent through the viscous-brittle transition by accommodating strain in the form of crystal plasticity before fracturing (comminution). Electron backscatter diffraction (EBSD) reveals up to 40° lattice distortion of biotite phenocrysts in zones of high shear, with negligible plasticity further away. Plagioclase microlites display a systematic plastic response to an increase in shear intensity, as recorded by an increase in lattice distortion towards the spine margin of up to 9°. This localisation of strain within the shear zone is also accompanied by the destabilisation of hydrous mineral phases (i.e. amphibole), compaction of pores (23-13% Φ), glass devitrification and magnetic anomalies. The narrow zone of disequilibrium textures suggests the likely effect of a thermal input due to strain localisation being the contributing factor. These observations are complimented by high-temperature high-velocity rotary shear experiments which simulate the deformation evolution during shear. Hence, understanding these shallow volcanic

  8. Norwood with right ventricle-to-pulmonary artery conduit is more effective than Norwood with Blalock-Taussig shunt for hypoplastic left heart syndrome: mathematic modeling of hemodynamics.

    Science.gov (United States)

    Mroczek, Tomasz; Małota, Zbigniew; Wójcik, Elżbieta; Nawrat, Zbigniew; Skalski, Janusz

    2011-12-01

    The introduction of right ventricle to pulmonary artery (RV-PA) conduit in the Norwood procedure for hypoplastic left heart syndrome resulted in a higher survival rate in many centers. A higher diastolic aortic pressure and a higher mean coronary perfusion pressure were suggested as the hemodynamic advantage of this source of pulmonary blood flow. The main objective of this study was the comparison of two models of Norwood physiology with different types of pulmonary blood flow sources and their hemodynamics. Based on anatomic details obtained from echocardiographic assessment and angiographic studies, two three-dimensional computer models of post-Norwood physiology were developed. The finite-element method was applied for computational hemodynamic simulations. Norwood physiology with RV-PA 5-mm conduit and Blalock-Taussig shunt (BTS) 3.5-mm shunt were compared. Right ventricle work, wall stress, flow velocity, shear rate stress, energy loss and turbulence eddy dissipation were analyzed in both models. The total work of the right ventricle after Norwood procedure with the 5-mm RV-PA conduit was lower in comparison to the 3.5-mm BTS while establishing an identical systemic blood flow. The Qp/Qs ratio was higher in the BTS group. Hemodynamic performance after Norwood with the RV-PA conduit is more effective than after Norwood with BTS. Computer simulations of complicated hemodynamics after the Norwood procedure could be helpful in establishing optimal post-Norwood physiology. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  9. In vitro efficacy of a gene-activated nerve guidance conduit incorporating non-viral PEI-pDNA nanoparticles carrying genes encoding for NGF, GDNF and c-Jun.

    Science.gov (United States)

    Lackington, William A; Raftery, Rosanne M; O'Brien, Fergal J

    2018-06-07

    Despite the success of tissue engineered nerve guidance conduits (NGCs) for the treatment of small peripheral nerve injuries, autografts remain the clinical gold standard for larger injuries. The delivery of neurotrophic factors from conduits might enhance repair for more effective treatment of larger injuries but the efficacy of such systems is dependent on a safe, effective platform for controlled and localised therapeutic delivery. Gene therapy might offer an innovative approach to control the timing, release and level of neurotrophic factor production by directing cells to transiently sustain therapeutic protein production in situ. In this study, a gene-activated NGC was developed by incorporating non-viral polyethyleneimine-plasmid DNA (PEI-pDNA) nanoparticles (N/P 7 ratio, 2μg dose) with the pDNA encoding for nerve growth factor (NGF), glial derived neurotrophic factor (GDNF) or the transcription factor c-Jun. The physicochemical properties of PEI-pDNA nanoparticles, morphology, size and charge, were shown to be suitable for gene delivery and demonstrated high Schwann cell transfection efficiency (60±13%) in vitro. While all three genes showed therapeutic potential in terms of enhancing neurotrophic cytokine production while promoting neurite outgrowth, delivery of the gene encoding for c-Jun showed the greatest capacity to enhance regenerative cellular processes in vitro. Ultimately, this gene-activated NGC construct was shown to be capable of transfecting both Schwann cells (S42 cells) and neuronal cells (PC12 and dorsal root ganglia) in vitro, demonstrating potential for future therapeutic applications in vivo. The basic requirements of biomaterial-based nerve guidance conduits have now been well established and include being able to bridge a nerve injury to support macroscopic guidance between nerve stumps, while being strong enough to withstand longitudinal tension and circumferential compression, in addition to being mechanically sound to facilitate

  10. Autologous alternative veins may not provide better outcomes than prosthetic conduits for below-knee bypass when great saphenous vein is unavailable.

    Science.gov (United States)

    Avgerinos, Efthymios D; Sachdev, Ulka; Naddaf, Abdallah; Doucet, Dannielle R; Mohapatra, Abhisekh; Leers, Steven A; Chaer, Rabih A; Makaroun, Michel S

    2015-08-01

    There is a need to better define the role of alternative autologous vein (AAV) segments over contemporary prosthetic conduits in patients with critical limb ischemia when great saphenous vein (GSV) is not available for use as the bypass conduit. Consecutive patients who underwent bypass to infrageniculate targets between 2007 and 2011 were categorized in three groups: GSV, AAV, and prosthetic. The primary outcome was graft patency. The secondary outcome was limb salvage. Cox proportional hazards regression was used to adjust for baseline confounding variables. A total of 407 infrainguinal bypasses to below-knee targets were analyzed; 255 patients (63%) received a single-segment GSV, 106 patients (26%) received an AAV, and 46 patients (11%) received a prosthetic conduit. Baseline characteristics were similar among groups, with the exception of popliteal targets and anticoagulation use being more frequent in the prosthetic group. Primary patency at 2 and 5 years was estimated at 47% and 32%, respectively, for the GSV group; 24% and 23% for the AAV group; and 43% and 38% for the prosthetic group. Primary assisted patency at 2 and 5 years was estimated at 71% and 55%, respectively, for the GSV group; 53% and 51% for the AAV group; and 45% and 40% for the prosthetic group. Secondary patency at 2 and 5 years was estimated at 75% and 60%, respectively, for the GSV group; 57% and 55% for the AAV group; and 46% and 41% for the prosthetic group. In Cox analysis, primary patency (hazard ratio [HR], 0.55; P < .001; 95% confidence interval [CI], 0.404-0.758), primary assisted patency (HR, 0.57; P = .004; 95% CI, 0.388-0.831), and secondary patency (HR, 0.56; P = .005; 95% CI, 0.372-0.840) were predicted by GSV compared with AAV, but there was no difference between AAV and prosthetic grafts except for the primary patency, for which prosthetic was protective (HR, 0.38; P < .001; 95% CI, 0.224-0.629). Limb salvage was similar among groups. AAV conduits may not offer a significant

  11. A new cable-in-conduit conductor magnet with insulated strands

    International Nuclear Information System (INIS)

    Yamaguchi, Satarou; Yamamoto, Junya; Motojima, Osamu.

    1995-09-01

    Many studies have used cable-in-conduit conductor (CICC) coils in trying to develop an AC superconducting magnet because of its enormous potential if AC losses were low and insulation voltage was high. The strands in the most recent CICC magnets are coated with chromium or another metal with high electrical resistance to order to induce current re-distribution among the strands and to avoid a quench caused by a current imbalance. Current re-distribution is highly complex and very difficult to analyze because the conditions of the strand surfaces and the contact areas vary greatly with the operation of the conductor. If, however, the cable currents were well-balanced, insulating the strands would be the best way to reduce AC losses. We propose a new CICC magnet structure featuring a current lead that balances the strand currents via its resistance. Having calculated current balances, we find that strand currents are well within the present parameters for nuclear fusion experiments and superconducting magnet energy storages. (author)

  12. Myectomy and LA-to-LV Conduit for Severe Calcific Mitral Stenosis and Hypertrophic Cardiomyopathy.

    Science.gov (United States)

    Meghji, Zahara; Nguyen, Anita; Geske, Jeffrey B; Schaff, Hartzell V

    2018-02-26

    Severe calcific mitral valve stenosis can rarely occur concomitantly with obstructive hypertrophic cardiomyopathy. In these patients, surgical decalcification of the stenotic mitral valve followed by mitral valve replacement carries significant operative risk and may result in paravalvular leakage, atrioventricular groove disruption, and excessive bleeding. We report the first 2 cases of obstructive hypertrophic cardiomyopathy with severe calcific mitral valve stenosis successfully treated with concomitant transaortic septal myectomy and bypass of the stenotic mitral valve using a valved left atrium to left ventricular conduit. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Laparoscopic ischemic conditioning of the stomach increases neovascularization of the gastric conduit in patients undergoing esophagectomy for cancer.

    Science.gov (United States)

    Pham, Thai H; Melton, Shelby D; McLaren, Patrick J; Mokdad, Ali A; Huerta, Sergio; Wang, David H; Perry, Kyle A; Hardaker, Hope L; Dolan, James P

    2017-09-01

    Gastric ischemic preconditioning has been proposed to improve blood flow and reduce the incidence of anastomotic complications following esophagectomy with gastric pull-up. This study aimed to evaluate the effect of prolonged ischemic preconditioning on the degree of neovascularization in the distal gastric conduit at the time of esophagectomy. A retrospective review of a prospectively maintained database identified 30 patients who underwent esophagectomy. The patients were divided into three groups: control (no preconditioning, n = 9), partial (short gastric vessel ligation only, n = 8), and complete ischemic preconditioning (left and short gastric vessel ligation, n = 13). Microvessel counts were assessed, using immunohistologic analysis to determine the degree of neovascularization at the distal gastric margin. The groups did not differ in age, gender, BMI, pathologic stage, or cancer subtype. Ischemic preconditioning durations were 163 ± 156 days for partial ischemic preconditioning, compared to 95 ± 50 days for complete ischemic preconditioning (P = 0.2). Immunohistologic analysis demonstrated an increase in microvessel counts of 29% following partial ischemic preconditioning (P = 0.3) and 67% after complete ischemic preconditioning (P gastric conduit. © 2017 Wiley Periodicals, Inc.

  14. Enhancement of Median Nerve Regeneration by Mesenchymal Stem Cells Engraftment in an Absorbable Conduit: Improvement of Peripheral Nerve Morphology with Enlargement of Somatosensory Cortical Representation.

    Directory of Open Access Journals (Sweden)

    Julia Teixeira Oliveira

    2014-10-01

    Full Text Available We studied the morphology and the cortical representation of the median nerve (MN, 10 weeks after a transection immediately followed by treatment with tubulization using a polycaprolactone (PCL conduit with or without bone marrow-derived mesenchymal stem cell (MSC transplant. In order to characterize the cutaneous representation of MN inputs in primary somatosensory cortex (S1, electrophysiological cortical mapping of the somatosensory representation of the forepaw and adjacent body parts was performed after acute lesion of all brachial plexus nerves, except for the MN. This was performed in ten adult male Wistar rats randomly assigned in 3 groups: MN Intact (n=4, PCL-Only (n=3 and PCL+MSC (n=3. Ten weeks before mapping procedures in animals from PCL-Only and PCL+MSC groups, animal were subjected to MN transection with removal of a 4-mm-long segment, immediately followed by suturing a PCL conduit to the nerve stumps with (PCL+MSC group or without (PCL-Only group injection of MSC into the conduit. After mapping the representation of the MN in S1, animals had a segment of the regenerated nerve processed for light and transmission electron microscopy. For histomorphometric analysis of the nerve segment, sample size was increased to 5 animals per experimental group. The PCL+MSC group presented a higher number of myelinated fibers and a larger cortical representation of MN inputs in S1 (3,383±390 fibers; 2.3 mm2, respectively than the PCL-Only group (2,226±575 fibers; 1.6 mm2. In conclusion, MSC-based therapy associated with PCL conduits can improve MN regeneration. This treatment seems to rescue the nerve representation in S1, thus minimizing the stabilization of new representations of adjacent body parts in regions previously responsive to the MN.

  15. Histological study of right ventricle-pulmonary artery valved conduit implantation (RPVC) in dogs with pulmonic stenosis.

    Science.gov (United States)

    Saida, Yuuto; Tanaka, Ryou; Fukushima, Ryuji; Hira, Satoshi; Hoshi, Katsuichiro; Soda, Aiko; Iizuka, Tomoya; Ishikawa, Taisuke; Nishimura, Taiki; Yamane, Yoshihisa

    2009-04-01

    We examined whether right ventricle-pulmonary artery valved conduit (RPVC) implantation can overcome the disadvantages of current procedures for pulmonic stenosis (PS). We histologically evaluated the feasibility of RPVC using a homograft in PS model dogs. Eight dogs underwent pulmonary artery banding (PAB) and then 12 weeks later were assigned to PAB (n=4) or PAB+RPVC (n=4) groups. Dogs in the PAB group received no treatment throughout the experimental period, whereas the PAB+RPVC group underwent RPVC. At 1 year after PAB, hearts and conduits were explanted from euthanized dogs and histologically evaluated. The ratios (%) of myocardial fibrosis on right ventricle (RV) epicardial, median and endocardial layers were significantly lower in the PAB+RPVC, than in the PAB group. The ratio of myocardial fibrosis on left ventricular (LV) epicardial and endocardial layers were significantly lower in the PAB+RPVC, than in the PAB group. Neo-intimal thickness in the anastomosis areas of the Denacol and PAB+RPVC groups was 42.77 +/- 30.19 and 88.30 +/- 27.24 microm, respectively, with no significant differences between the groups. Calcification and neo- intima hypertrophy were not obvious in the valve area. Immunohistological staining showed that the internal surface of the anastomosis and intermediate areas were positive for endothelial cells. We concluded that RPVC using a bioprosthetic graft can apparently overcome the disadvantages of current procedures for pulmonic stenosis.

  16. Impact of Age and Aerobic Exercise Training on Conduit Artery Wall Thickness: Role of the Shear Pattern.

    Science.gov (United States)

    Tanahashi, Koichiro; Kosaki, Keisei; Sawano, Yuriko; Yoshikawa, Toru; Tagawa, Kaname; Kumagai, Hiroshi; Akazawa, Nobuhiko; Maeda, Seiji

    2017-01-01

    Hemodynamic shear stress is the frictional force of blood on the arterial wall. The shear pattern in the conduit artery affects the endothelium and may participate in the development and progression of atherosclerosis. We investigated the role of the shear pattern in age- and aerobic exercise-induced changes in conduit artery wall thickness via cross-sectional and interventional studies. In a cross-sectional study, we found that brachial shear rate patterns and brachial artery intima-media thickness (IMT) correlated with age. Additionally, brachial artery shear rate patterns were associated with brachial artery IMT in 102 middle-aged and older individuals. In an interventional study, 39 middle-aged and older subjects were divided into 2 groups: control and exercise. The exercise group completed 12 weeks of aerobic exercise training. Aerobic exercise training significantly increased the antegrade shear rate and decreased the retrograde shear rate and brachial artery IMT. Moreover, changes in the brachial artery antegrade shear rate and the retrograde shear rate correlated with the change in brachial artery IMT. The results of the present study indicate that changes in brachial artery shear rate patterns may contribute to age- and aerobic exercise training-induced changes in brachial artery wall thickness. © 2017 S. Karger AG, Basel.

  17. Radial Artery as a Coronary Artery Bypass Conduit: 20-Year Results.

    Science.gov (United States)

    Gaudino, Mario; Tondi, Paolo; Benedetto, Umberto; Milazzo, Valentina; Flore, Roberto; Glieca, Franco; Ponziani, Francesca Romana; Luciani, Nicola; Girardi, Leonard N; Crea, Filippo; Massetti, Massimo

    2016-08-09

    There is a lack of evidence for the choice of the second conduit in coronary surgery. The radial artery (RA) is a possible option, but few data on very-long-term outcomes exist. This study describes 20-year results of RA grafts used for coronary artery bypass grafting and the effects of RA removal on forearm circulation. We report the results of the prospective 20-year follow-up of the first 100 consecutive patients who received the RA as a coronary bypass conduit at our institution. Follow-up was 100% complete. There were 64 deaths, 23 (35.9%) from cardiovascular causes. Kaplan-Meier 20-year survival was 31%. Of the 36 survivors, 33 (91.6%) underwent RA graft control at a mean of 19.0 ± 2.5 years after surgery. The RA was found to be patent in 24 cases (84.8% patency). In the overall population, probability of graft failure at 20 years was 19.0 ± 0.2% for the left internal thoracic artery (ITA), 25.0 ± 0.2% for the RA, and 55.0 ± 0.2% for the saphenous vein (p = 0.002 for RA vs. saphenous vein, 0.11 for RA vs. ITA, and p 90%, but not location of distal anastomosis, significantly influenced long-term RA graft patency. No patients reported hand or forearm symptoms. The ulnar artery diameter was increased in the operated arm (2.44 ± 0.43 mm vs. 2.01 ± 0.47 mm; p 90% stenosis. RA harvesting does not lead to hand or forearm symptoms, even at a very-long-term follow-up. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Neural network based inspection of voids and karst conduits in hydro-electric power station tunnels using GPR

    Science.gov (United States)

    Kilic, Gokhan; Eren, Levent

    2018-04-01

    This paper reports on the fundamental role played by Ground Penetrating Radar (GPR), alongside advanced processing and presentation methods, during the tunnel boring project at a Dam and Hydro-Electric Power Station. It identifies from collected GPR data such issues as incomplete grouting and the presence of karst conduits and voids and provides full details of the procedures adopted. In particular, the application of collected GPR data to the Neural Network (NN) method is discussed.

  19. Three-dimensional fluid mechanics of particulate two-phase flows in U-bend and helical conduits

    Science.gov (United States)

    Tiwari, Prashant; Antal, Steven P.; Podowski, Michael Z.

    2006-04-01

    The results of numerous studies performed to date have shown that the performance of various hydraulic systems can be significantly improved by using curved conduit geometries instead of straight tubes. In particular, the formation of Dean vortices, which enhance the development of centrifugal instabilities, has been identified as a factor behind reducing the near-wall concentration buildup in particulate flow devices (e.g., in membrane filtration modules). Still, several issues regarding the effect of conduit curvature on local multidimensional phenomena governing fluid flow still remain open. A related issue is concerned with the impact that conduit geometry makes on the concentration distribution of a dispersed phase in two-phase flows in general, and in particulate flows (solid/liquid or solid/gas suspensions) in particular. It turns out that only very limited efforts have been made in the past to understand the fluid mechanics of such flows via advanced computer simulations. The purpose of this paper is to present the results of full three-dimensional (3D) theoretical and numerical analyses of single- and two-phase dilute particle/liquid flows in U-bend and helical curved conduits. The numerical analysis is based on computational fluid dynamics (CFD) simulations performed using a state-of-the-art multiphase flow computer code, NPHASE. The major issues discussed in the first part of the paper are concerned with the effect of curved/coiled geometry on the evolution of flow field and the associated wall shear. It has been demonstrated that the primary curvature (a common factor for both the U-bend and helix geometries) may cause a substantial asymmetry in the radial distribution of the main flow velocity. This, in turn, leads to a significant, albeit highly nonuniform, increase in the wall shear stress. Specifically, the wall shear around the outer half of tube circumference may become twice the corresponding value for a straight tube, and gradually decrease to

  20. Detection of the normal zone with cowound sensors in cable-in conduit conductors

    International Nuclear Information System (INIS)

    Martovetsky, N.N.; Chaplin, M.R.

    1996-01-01

    Tokamaks in the future will use superconducting cable-in-conduit- conductors (CICC) in all poloidal field (PF) and toroidal field (TF) magnets. Conventional quench detection, the measurement of small resistive normal zone voltages ( 4 kV). In the quench detection design for TPX, we have considered several different locations for internal co-wound voltage sensors in the cable cross-section as the primary mechanism to cancel this inductive noise. The Noise Rejection Experiment (NRE) at LLNL has been designed to evaluate which internal locations will produce the best inductive- noise cancellation, and provide us with experimental data for comparison with previously developed theory. The details of the experiments and resulting data are presented and analyzed

  1. C3 toxin and poly-DL-lactide-ε-caprolactone conduits in the critically damaged peripheral nervous system: a combined therapeutic approach.

    Science.gov (United States)

    Leibig, Nico; Boyle, Veronika; Kraus, Daniel; Stark, Gerhard Bjoern; Penna, Vincenzo

    2015-03-01

    Peripheral nerve regeneration over longer distances through conduits is limited. In the presented study, critical size nerve gap bridging with a poly-DL-lactide-ε-caprolactone (PLC) conduit was combined with application of C3 toxin to facilitate axonal sprouting. The PLC filled with fibrin (n = 10) and fibrin gel loaded with 1-μg C3-C2I and 2-μg C2II (n = 10) were compared to autologous nerve grafts (n = 10) in a 15-mm sciatic nerve gap lesion model of the rat. Functional and electrophysiological analyses were performed before histological evaluation. Evaluation of motor function and nerve conduction velocity at 16 weeks revealed no differences between the groups. All histological parameters and muscle weight were significantly elevated in nerve graft group. No differences were observed in both PLC groups. The PLCs are permissive for nerve regeneration over a 15-mm defect in rats. Intraluminal application of C3 toxin did not lead to significant enhancement of nerve sprouting.

  2. Aerodynamic improvement of the assembly through which gas conduits are taken into a smoke stack by simulating gas flow on a computer

    Science.gov (United States)

    Prokhorov, V. B.; Fomenko, M. V.; Grigor'ev, I. V.

    2012-06-01

    Results from computer simulation of gas flow motion for gas conduits taken on one and two sides into the gas-removal shaft of a smoke stack with a constant cross section carried out using the SolidWorks and FlowVision application software packages are presented.

  3. Relaxation of microparticles exposed to hydrodynamic forces in microfluidic conduits.

    Science.gov (United States)

    Janča, Josef; Halabalová, Věra; Polášek, Vladimír; Vašina, Martin; Menshikova, Anastasia Yu

    2011-02-01

    The behavior of microparticles exposed to gravitational and lift forces and to the velocity gradient in flow velocity profile formed in microfluidic conduits is studied from the viewpoint of the transient period (the relaxation) between the moment at which a particle starts to be transported by the hydrodynamic flow and the time at which it reaches an equilibrium position, characterized by a balance of all active forces. The theoretical model allowing the calculation of the relaxation time is proposed. The numerical calculus based on the proposed model is compared with the experimental data obtained under different experimental conditions, namely, for different lengths of microfluidic channels, different average linear velocities of the carrier liquid, and different sizes and densities of the particles used in the study. The results are important for the optimization of microfluidic separation units such as microthermal field-flow fractionation channels in which the separation or manipulation of the microparticles of various origin, synthetic, natural, biological, etc., is performed under similar experimental conditions but by applying an additional thermodynamic force.

  4. Hypoglossal-Facial Nerve Reconstruction Using a Y-Tube-Conduit Reduces Aberrant Synkinetic Movements of the Orbicularis Oculi and Vibrissal Muscles in Rats

    Directory of Open Access Journals (Sweden)

    Yasemin Kaya

    2014-01-01

    Full Text Available The facial nerve is the most frequently damaged nerve in head and neck trauma. Patients undergoing facial nerve reconstruction often complain about disturbing abnormal synkinetic movements of the facial muscles (mass movements, synkinesis which are thought to result from misguided collateral branching of regenerating motor axons and reinnervation of inappropriate muscles. Here, we examined whether use of an aorta Y-tube conduit during reconstructive surgery after facial nerve injury reduces synkinesis of orbicularis oris (blink reflex and vibrissal (whisking musculature. The abdominal aorta plus its bifurcation was harvested (N = 12 for Y-tube conduits. Animal groups comprised intact animals (Group 1, those receiving hypoglossal-facial nerve end-to-end coaptation alone (HFA; Group 2, and those receiving hypoglossal-facial nerve reconstruction using a Y-tube (HFA-Y-tube, Group 3. Videotape motion analysis at 4 months showed that HFA-Y-tube group showed a reduced synkinesis of eyelid and whisker movements compared to HFA alone.

  5. Hypoglossal-facial nerve reconstruction using a Y-tube-conduit reduces aberrant synkinetic movements of the orbicularis oculi and vibrissal muscles in rats.

    Science.gov (United States)

    Kaya, Yasemin; Ozsoy, Umut; Turhan, Murat; Angelov, Doychin N; Sarikcioglu, Levent

    2014-01-01

    The facial nerve is the most frequently damaged nerve in head and neck trauma. Patients undergoing facial nerve reconstruction often complain about disturbing abnormal synkinetic movements of the facial muscles (mass movements, synkinesis) which are thought to result from misguided collateral branching of regenerating motor axons and reinnervation of inappropriate muscles. Here, we examined whether use of an aorta Y-tube conduit during reconstructive surgery after facial nerve injury reduces synkinesis of orbicularis oris (blink reflex) and vibrissal (whisking) musculature. The abdominal aorta plus its bifurcation was harvested (N = 12) for Y-tube conduits. Animal groups comprised intact animals (Group 1), those receiving hypoglossal-facial nerve end-to-end coaptation alone (HFA; Group 2), and those receiving hypoglossal-facial nerve reconstruction using a Y-tube (HFA-Y-tube, Group 3). Videotape motion analysis at 4 months showed that HFA-Y-tube group showed a reduced synkinesis of eyelid and whisker movements compared to HFA alone.

  6. Current distribution in Cable-In-Conduit Conductors

    International Nuclear Information System (INIS)

    Ferri, M.A.

    1994-05-01

    A numerical study of the current distribution in Cable-In-Conduit Conductors (CICC's) experiencing linearly ramping transport currents and transverse magnetic fields was conducted for both infinitely long, periodic cables and finite length cables terminated in low resistance joints. The goal of the study was to gain insight into the phenomenon known as Ramp Rate Limitation, an as yet unexplained correspondence between maximum attainable current and the ramp time taken to reach that current in CICC superconducting magnets. A discrete geometric model of a 27 strand multiply twisted CICC was developed to effectively represent the flux linkages, mutual inductances, and resistive contact points between the strands of an experimentally tested cable. The results of the numerical study showed that for fully periodic cables, the current imbalances due to ramping magnetic fields and ramping transport currents are negligible in the range of experimentally explored operating conditions. For finite length, joint terminated cables, however, significant imbalances can exist. Unfortunately, quantitative results are limited by a lack of knowledge of the transverse resistance between strands in the joints. Nonetheless, general results are presented showing the dependency of the imbalance on cable length, ramp time, and joint resistance for both ramping transverse magnet fields and ramping transport currents. At the conclusion of the study, it is suggested that calculated current imbalances in a finite length cable could cause certain strands to prematurely ''quench'' -- become non-superconducting --thus leading to an instability for the entire cable. This numerically predicted ''current imbalance instability'' is compared to the experimentally observed Ramp Rate Limitation for the 27 strand CICC sample

  7. Assessing lateral flows and solute transport during floods in a conduit-flow-dominated karst system using the inverse problem for the advection–diffusion equation

    Directory of Open Access Journals (Sweden)

    C. Cholet

    2017-07-01

    Full Text Available The aim of this study is to present a framework that provides new ways to characterize the spatio-temporal variability of lateral exchanges for water flow and solute transport in a karst conduit network during flood events, treating both the diffusive wave equation and the advection–diffusion equation with the same mathematical approach, assuming uniform lateral flow and solute transport. A solution to the inverse problem for the advection–diffusion equations is then applied to data from two successive gauging stations to simulate flows and solute exchange dynamics after recharge. The study site is the karst conduit network of the Fourbanne aquifer in the French Jura Mountains, which includes two reaches characterizing the network from sinkhole to cave stream to the spring. The model is applied, after separation of the base from the flood components, on discharge and total dissolved solids (TDSs in order to assess lateral flows and solute concentrations and compare them to help identify water origin. The results showed various lateral contributions in space – between the two reaches located in the unsaturated zone (R1, and in the zone that is both unsaturated and saturated (R2 – as well as in time, according to hydrological conditions. Globally, the two reaches show a distinct response to flood routing, with important lateral inflows on R1 and large outflows on R2. By combining these results with solute exchanges and the analysis of flood routing parameters distribution, we showed that lateral inflows on R1 are the addition of diffuse infiltration (observed whatever the hydrological conditions and localized infiltration in the secondary conduit network (tributaries in the unsaturated zone, except in extreme dry periods. On R2, despite inflows on the base component, lateral outflows are observed during floods. This pattern was attributed to the concept of reversal flows of conduit–matrix exchanges, inducing a complex water mixing effect

  8. Hydraulic tomography of discrete networks of conduits and fractures in a karstic aquifer by using a deterministic inversion algorithm

    Science.gov (United States)

    Fischer, P.; Jardani, A.; Lecoq, N.

    2018-02-01

    In this paper, we present a novel inverse modeling method called Discrete Network Deterministic Inversion (DNDI) for mapping the geometry and property of the discrete network of conduits and fractures in the karstified aquifers. The DNDI algorithm is based on a coupled discrete-continuum concept to simulate numerically water flows in a model and a deterministic optimization algorithm to invert a set of observed piezometric data recorded during multiple pumping tests. In this method, the model is partioned in subspaces piloted by a set of parameters (matrix transmissivity, and geometry and equivalent transmissivity of the conduits) that are considered as unknown. In this way, the deterministic optimization process can iteratively correct the geometry of the network and the values of the properties, until it converges to a global network geometry in a solution model able to reproduce the set of data. An uncertainty analysis of this result can be performed from the maps of posterior uncertainties on the network geometry or on the property values. This method has been successfully tested for three different theoretical and simplified study cases with hydraulic responses data generated from hypothetical karstic models with an increasing complexity of the network geometry, and of the matrix heterogeneity.

  9. Neural-differentiated mesenchymal stem cells incorporated into muscle stuffed vein scaffold forms a stable living nerve conduit.

    Science.gov (United States)

    Hassan, Nur Hidayah; Sulong, Ahmad Fadzli; Ng, Min-Hwei; Htwe, Ohnmar; Idrus, Ruszymah B H; Roohi, Sharifah; Naicker, Amaramalar S; Abdullah, Shalimar

    2012-10-01

    Autologous nerve grafts to bridge nerve gaps have donor site morbidity and possible neuroma formation resulting in development of various methods of bridging nerve gaps without using autologous nerve grafts. We have fabricated an acellular muscle stuffed vein seeded with differentiated mesenchymal stem cells (MSCs) as a substitute for nerve autografts. Human vein and muscle were both decellularized by liquid nitrogen immersion with subsequent hydrolysis in hydrochloric acid. Human MSCs were subjected to a series of treatments with a reducing agent, retinoic acid, and a combination of trophic factors. The differentiated MSCs were seeded on the surface of acellular muscle tissue and then stuffed into the vein. Our study showed that 35-75% of the cells expressed neural markers such as S100b, glial fibrillary acidic protein (GFAP), p75 NGF receptor, and Nestin after differentiation. Histological and ultra structural analyses of muscle stuffed veins showed attachment of cells onto the surface of the acellular muscle and penetration of the cells into the hydrolyzed fraction of muscle fibers. We implanted these muscle stuffed veins into athymic mice and at 8 weeks post-implantation, the acellular muscle tissue had fully degraded and replaced with new matrix produced by the seeded cells. The vein was still intact and no inflammatory reactions were observed proving the biocompatibility and biodegradability of the conduit. In conclusion, we have successfully formed a stable living nerve conduit which may serve as a substitute for autologous nerves. Copyright © 2012 Orthopaedic Research Society.

  10. Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients.

    Science.gov (United States)

    Girgis, Karim K; Youssef, Maha M I; ElZayyat, Nashwa S

    2014-10-01

    One of the methods proposed in cases of difficult airway management in children is using a supraglottic airway device as a conduit for tracheal intubation. The aim of this study was to compare the efficacy of the Air-Q Intubating Laryngeal Airway (Air-Q) and the Cobra Perilaryngeal Airway (CobraPLA) to function as a conduit for fiber optic-guided tracheal intubation in pediatric patients. A total of 60 children with ages ranging from 1 to 6 years, undergoing elective surgery, were randomized to have their airway managed with either an Air-Q or CobraPLA. Outcomes recorded were the success rate, time and number of attempts required for fiber optic-guided intubation and the time required for device removal after intubation. We also recorded airway leak pressure (ALP), fiber optic grade of glottic view and occurrence of complications. Both devices were successfully inserted in all patients. The intubation success rate was comparable with the Air-Q and the CobraPLA (96.7% vs. 90%), as was the first attempt success rate (90% vs. 80%). The intubation time was significantly longer with the CobraPLA (29.5 ± 10.9 s vs. 23.2 ± 9.8 s; P fiber optic grade of glottic view was comparable with the two devices. The CobraPLA was associated with a significantly higher incidence of blood staining of the device on removal and post-operative sore throat. Both the Air-Q and CobraPLA can be used effectively as a conduit for fiber optic-guided tracheal intubation in children. However, the Air-Q proved to be superior due to a shorter intubation time and less airway morbidity compared with the CobraPLA.

  11. Frictional melting dynamics in the upper conduit: A chemical answer to a complex physical question

    Science.gov (United States)

    Henton De Angelis, S.; Lavallee, Y.; Kendrick, J. E.; Hornby, A.; von Aulock, F. W.; Clesham, S.; Hirose, T.; Perugini, D.

    2013-12-01

    During volcanic eruptions the generation of frictional heat along the walls of the shallow conduit leads to melting of the rocks along the slip interface. Frictional melting has previously been described as a process out of thermodynamic equilibrium, but upon slip and mingling of the melt batches, homogeneity can be achieved, and may have an h important rheological control on the dynamics of slip. To test melt homogenization in the frictional melt zones of volcanic conduits we performed constant-rate slip experiments under controlled stress conditions using a high-velocity rotary shear apparatus. Volcanic dome samples from three different volcanoes (Volcán De Colima, Soufrière Hills Volcano and Santiaguito Volcano) were investigated. Each sample was subjected to a stress of 1 MPa and slip rate of 1 m/s. For each sample set 5 experiments were conducted: 1) experiment stopped at the onset of melting; 2) experiment stopped on the formation of a full melt layer; 3) experiment stopped after 5m of slip at steady state conditions; 4) experiment stopped after 10m of slip at steady state conditions; 5) experiment stopped after 15m of slip at steady state conditions. We analyzed the resulting proto-melt zones using micron sized X-ray spectroscopy in the high-brightness synchrotron beamline I18 (at Diamond Light Source UK). Particular focus was given to the concentration variance analysis of Rare Earth Elements as their mobilities can be used to precisely quantify the degree and timescale of homogenisation involved during frictional melting. This study refines our understanding of the chemical process of melting and mixing which carry important consequences for the rheological control on the physical dynamics of slip.

  12. Reverse saphenous conduit flap in small animals: Clinical applications and outcomes

    Directory of Open Access Journals (Sweden)

    Ross C. Elliott

    2014-08-01

    Full Text Available Due to the lack of skin elasticity defects of the distal hind limb can be a challenge to close. This article assesses a well-described, but completely under-used technique for closure of wounds on the distal tarsus. The technique was used with good success in six cases presenting to the Bryanston Veterinary Hospital with a wide range of underlying pathology ranging from trauma to neoplastic disease of the tarsus. All six cases were treated with a reverse saphenous conduit flap and two of them underwent radiation therapy with no adverse side effects. All cases showed excellent results with a very low degree of flap necrosis that never exceeded 15% of the total flap area. This skin flap provides an excellent treatment method that is reliable in closure of defects of the distal tarsus with few adverse effects. To the author’s knowledge there has been only one previously published report on the clinical use of this type of skin flap,even though the flap is well described in most texts.

  13. Troubles des conduites alimentaires et tempérament cyclothymique: étude transversale à propos de 107 étudiants Tunisiens

    Science.gov (United States)

    Jaweher, Masmoudi; Sonda, Trabelsi; Uta, Ouali; Inès, Feki; Rim, Sallemi; Imene, Baati; Abdelaziz, Jaoua

    2014-01-01

    Introduction Les objectifs de notre étude ont été d'estimer la prévalence des troubles des conduites alimentaires (TCA) chez les jeunes tunisiens et étudier la relation entre le tempérament cyclothymique et les TCA. Méthodes Nous avons ainsi mené une étude transversale descriptive et analytique. Elle a concerné 107 étudiants de l'Institut de Presse et des Sciences de l'Information de la Manouba, Tunisie. Pour l’évaluation des TCA, nous avons procédé par la passation de l'auto questionnaire EAT 40, dans sa version validée en Tunisie. C'est l'outil le plus utilisé pour le dépistage des TCA dans le monde. Pour l’évaluation du tempérament cyclothymique, nous avons utilisé le TEMPS A dans sa version arabe validée. Une fiche épidémiologique associée a permis de recueillir quelques facteurs sociodémographiques et hygiéno-diététiques. Résultats La prévalence des troubles de conduites alimentaires a été de 24,3%. Le pourcentage des étudiants ayant un score de tempérament cyclothymique ≥14 a été de 37,4%. Une association a été trouvée entre les troubles de conduites alimentaires et le tempérament affectif cyclothymique que ce soit selon l'approche dimensionnelle (p=0,005) ou selon celle catégorielle (p=0,046). Le tempérament cyclothymique multiplie par deux le risque de développer un TCA chez les étudiants de sexe féminin (p=0,04). Conclusion Es TCA sont fréquents chez nos étudiants particulièrement de sexe féminin. De plus, la présence d'un tempérament cyclothymique associé permettrait de suspecter doublement une appartenance au spectre bipolaire et devrait conduire à une attention particulière de la part du clinicien pour définir au mieux les stratégies thérapeutiques. PMID:25404977

  14. Design and synthesis of elastin-like polypeptides for an ideal nerve conduit in peripheral nerve regeneration

    International Nuclear Information System (INIS)

    Hsueh, Yu-Sheng; Savitha, S.; Sadhasivam, S.; Lin, Feng-Huei; Shieh, Ming-Jium

    2014-01-01

    The study involves design and synthesis of three different elastin like polypeptide (ELP) gene monomers namely ELP1, ELP2 and ELP3 that encode for ELP proteins. The formed ELPs were assessed as an ideal nerve conduit for peripheral nerve regeneration. ELP1 was constructed with a small elongated pentapeptide carrying VPGVG sequence to mimic the natural polypeptide ELP. The ELP2 was designed by the incorporation of 4-penta peptide chains to improve the biocompatibility and mechanical strength. Thus, the third position in unique VPGVG was replaced with alanine to VPAVG and in a similar way modified to VPGKG, VPGEG and VPGIG with the substitution of lysine, glutamic acid and isoleucine. In ELP3, fibronectin C5 domain endowed with REDV sequence was introduced to improve the cell attachment. The ELP1, ELP2 and ELP3 proteins expressed by Escherichia coli were purified by inverse transition cycling (ITC). The purified ELPs were confirmed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and western blotting. The Schwann cell (SC) morphology and cell adhesion were assessed by fabrication of ELP membrane cross-linked with glutaraledhyde. The Schwann cell proliferation was measured by WST-1 assay. Immunofluorostaining of Schwann cells was accomplished with SC specific phenotypic marker, S100. - Highlights: • Design and synthesis of three gene monomers of elastin like polypeptides (ELP1, 2 and 3) were reported. • Molecular weight of ITC purified ELP1, ELP2 and ELP3 was in the range of 37–38 kDa. • Schwann cell adhesion was found to be prominent in ELP3 and could be used as nerve conduit for peripheral nerve regeneration

  15. Design and synthesis of elastin-like polypeptides for an ideal nerve conduit in peripheral nerve regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Hsueh, Yu-Sheng [Institute of Biomedical Engineering, College of Engineering, National Taiwan University, Taipei 100, Taiwan (China); Institute of Biomedical Engineering, College of Medicine, National Taiwan University, Taipei 100, Taiwan (China); Savitha, S. [Institute of Biomedical Engineering, College of Engineering, National Taiwan University, Taipei 100, Taiwan (China); Department of Biotechnology, Sree Sastha Institute of Engineering and Technology, Chennai (India); Institute of Biomedical Engineering, College of Medicine, National Taiwan University, Taipei 100, Taiwan (China); Sadhasivam, S. [Division of Biomedical Engineering and Nanomedicine Research, National Health Research Institutes, Miaoli 350, Taiwan (China); Lin, Feng-Huei, E-mail: double@ntu.edu.tw [Institute of Biomedical Engineering, College of Engineering, National Taiwan University, Taipei 100, Taiwan (China); Division of Biomedical Engineering and Nanomedicine Research, National Health Research Institutes, Miaoli 350, Taiwan (China); Institute of Biomedical Engineering, College of Medicine, National Taiwan University, Taipei 100, Taiwan (China); Shieh, Ming-Jium [Institute of Biomedical Engineering, College of Engineering, National Taiwan University, Taipei 100, Taiwan (China); College of Medicine, National Taiwan University Hospital, Taipei 100, Taiwan (China); Institute of Biomedical Engineering, College of Medicine, National Taiwan University, Taipei 100, Taiwan (China)

    2014-05-01

    The study involves design and synthesis of three different elastin like polypeptide (ELP) gene monomers namely ELP1, ELP2 and ELP3 that encode for ELP proteins. The formed ELPs were assessed as an ideal nerve conduit for peripheral nerve regeneration. ELP1 was constructed with a small elongated pentapeptide carrying VPGVG sequence to mimic the natural polypeptide ELP. The ELP2 was designed by the incorporation of 4-penta peptide chains to improve the biocompatibility and mechanical strength. Thus, the third position in unique VPGVG was replaced with alanine to VPAVG and in a similar way modified to VPGKG, VPGEG and VPGIG with the substitution of lysine, glutamic acid and isoleucine. In ELP3, fibronectin C5 domain endowed with REDV sequence was introduced to improve the cell attachment. The ELP1, ELP2 and ELP3 proteins expressed by Escherichia coli were purified by inverse transition cycling (ITC). The purified ELPs were confirmed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and western blotting. The Schwann cell (SC) morphology and cell adhesion were assessed by fabrication of ELP membrane cross-linked with glutaraledhyde. The Schwann cell proliferation was measured by WST-1 assay. Immunofluorostaining of Schwann cells was accomplished with SC specific phenotypic marker, S100. - Highlights: • Design and synthesis of three gene monomers of elastin like polypeptides (ELP1, 2 and 3) were reported. • Molecular weight of ITC purified ELP1, ELP2 and ELP3 was in the range of 37–38 kDa. • Schwann cell adhesion was found to be prominent in ELP3 and could be used as nerve conduit for peripheral nerve regeneration.

  16. Controls on magma permeability in the volcanic conduit during the climactic phase of the Kos Plateau Tuff eruption (Aegean Arc)

    Science.gov (United States)

    Degruyter, W.; Bachmann, O.; Burgisser, A.

    2010-01-01

    X-ray computed microtomography (µCT) was applied to pumices from the largest Quaternary explosive eruption of the active South Aegean Arc (the Kos Plateau Tuff; KPT) in order to better understand magma permeability within volcanic conduits. Two different types of pumices (one with highly elongated bubbles, tube pumice; and the other with near spherical bubbles, frothy pumice) produced synchronously and with identical chemical composition were selected for µCT imaging to obtain porosity, tortuosity, bubble size and throat size distributions. Tortuosity drops on average from 2.2 in frothy pumice to 1.5 in tube pumice. Bubble size and throat size distributions provide estimates for mean bubble size (~93-98 μm) and mean throat size (~23-29 μm). Using a modified Kozeny-Carman equation, variations in porosity, tortuosity, and throat size observed in KPT pumices explain the spread found in laboratory measurements of the Darcian permeability. Measured difference in inertial permeability between tube and frothy pumices can also be partly explained by the same variables but require an additional parameter related to the internal roughness of the porous medium (friction factor f 0 ). Constitutive equations for both types of permeability allow the quantification of laminar and turbulent gas escape during ascent of rhyolitic magma in volcanic conduits.

  17. Chilling of dormant buds hyperinduces FLOWERING LOCUS T and recruits GA-inducible 1,3-beta-glucanases to reopen signal conduits and release dormancy in Populus.

    Science.gov (United States)

    Rinne, Päivi L H; Welling, Annikki; Vahala, Jorma; Ripel, Linda; Ruonala, Raili; Kangasjärvi, Jaakko; van der Schoot, Christiaan

    2011-01-01

    In trees, production of intercellular signals and accessibility of signal conduits jointly govern dormancy cycling at the shoot apex. We identified 10 putative cell wall 1,3-β-glucanase genes (glucan hydrolase family 17 [GH17]) in Populus that could turn over 1,3-β-glucan (callose) at pores and plasmodesmata (PD) and investigated their regulation in relation to FT and CENL1 expression. The 10 genes encode orthologs of Arabidopsis thaliana BG_ppap, a PD-associated glycosylphosphatidylinositol (GPI) lipid-anchored protein, the Arabidopsis PD callose binding protein PDCB, and a birch (Betula pendula) putative lipid body (LB) protein. We found that these genes were differentially regulated by photoperiod, by chilling (5°C), and by feeding of gibberellins GA(3) and GA(4). GA(3) feeding upregulated all LB-associated GH17s, whereas GA(4) upregulated most GH17s with a GPI anchor and/or callose binding motif, but only GA(4) induced true bud burst. Chilling upregulated a number of GA biosynthesis and signaling genes as well as FT, but not CENL1, while the reverse was true for both GA(3) and GA(4). Collectively, the results suggest a model for dormancy release in which chilling induces FT and both GPI lipid-anchored and GA(3)-inducible GH17s to reopen signaling conduits in the embryonic shoot. When temperatures rise, the reopened conduits enable movement of FT and CENL1 to their targets, where they drive bud burst, shoot elongation, and morphogenesis.

  18. Fabrication of nerve guidance conduit with luminal filler as scaffold for peripheral nerve repair

    International Nuclear Information System (INIS)

    Aranilla, Charito T.; Wach, Rodoslaw; Ulanski, Piotr

    2015-01-01

    Peripheral nerve injury is a serious health concern for society, affecting trauma patients, many of whom acquire life-long disability. The gold standard of treatment for peripheral nerve injury is the use of nerve grafts, wherein nerve autograft or allograft is used to bridge the gap in the damaged nerve. Nerve guidance conduits (NGCs) are an attractive alternative to nerve autografts for aiding in the regeneration of peripheral nerve tissue. NGCs are small cylinders or tubes composed of either natural or synthetic biomaterials that are used to axon regeneration. The ends of the damaged nerve are inserted into either end of the cylinder and the NGC acts both as a connecting bridge for the severed nerve ends as well as a protective shelter for the regenerating nerve. This study aims at fabricating nerve guidance conduits with luminal structure based on synthetic biodegradable and biocompatible polymers such as poly (trimethylene carbonate ) (PTMC), poly (lactic acid) (PLA) and poly (caprolactone) (PCL). Initial base materials for fabrication were PLA acid tubes compared to PCL tubes when prepared by spray and dip-coating methods. The morphology of the tubes where examined by SEM and results showed better porosity of PLA acid tubes compared to PCL tubes when prepared by spraying technique. Poly(lactic acid) was then blended with poly(trimethylene carbonate) at a ratio of 1:4 (5% total polymer content) for further fabrication. Electron beam radiation (25 and 50 kGy) was employed for sterilization and the changes in properties induced by irradiation in comprising polymers were evaluated. The wettability, mechanical thermal properties were not significantly changed by irradiation.In a separate experiment, synthesis of carboxymethyl chitosan hydrogel crosslinked by electron beam radiation was studied to create a luminal filler for PTMC-PLA tubes. Based on proper viscosity of solution before crosslinking, sufficient gel fraction and swelling, 10% w/v concentration of

  19. Scaffoldless tissue-engineered nerve conduit promotes peripheral nerve regeneration and functional recovery after tibial nerve injury in rats

    Institute of Scientific and Technical Information of China (English)

    Aaron M. Adams; Keith W. VanDusen; Tatiana Y. Kostrominova; Jacob P. Mertens; Lisa M. Larkin

    2017-01-01

    Damage to peripheral nerve tissue may cause loss of function in both the nerve and the targeted muscles it innervates. This study compared the repair capability of engineered nerve conduit (ENC), engineered fibroblast conduit (EFC), and autograft in a 10-mm tibial nerve gap. ENCs were fabricated utilizing primary fibroblasts and the nerve cells of rats on embryonic day 15 (E15). EFCs were fabricated utilizing primary fi-broblasts only. Following a 12-week recovery, nerve repair was assessed by measuring contractile properties in the medial gastrocnemius muscle, distal motor nerve conduction velocity in the lateral gastrocnemius, and histology of muscle and nerve. The autografts, ENCs and EFCs reestablished 96%, 87% and 84% of native distal motor nerve conduction velocity in the lateral gastrocnemius, 100%, 44% and 44% of native specific force of medical gastrocnemius, and 63%, 61% and 67% of native medial gastrocnemius mass, re-spectively. Histology of the repaired nerve revealed large axons in the autograft, larger but fewer axons in the ENC repair, and many smaller axons in the EFC repair. Muscle histology revealed similar muscle fiber cross-sectional areas among autograft, ENC and EFC repairs. In conclusion, both ENCs and EFCs promot-ed nerve regeneration in a 10-mm tibial nerve gap repair, suggesting that the E15 rat nerve cells may not be necessary for nerve regeneration, and EFC alone can suffice for peripheral nerve injury repair.

  20. Experimental composite guidance conduits for peripheral nerve repair: An evaluation of ion release

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X.F. [Department of Biological Sciences and Medical Engineering Design and Innovation Centre, Cork Institute of Technology, Cork (Ireland); Coughlan, A. [Inamori School of Engineering, Alfred University, Alfred, NY. 14802 (United States); O' Shea, H. [Department of Biological Sciences and Medical Engineering Design and Innovation Centre, Cork Institute of Technology, Cork (Ireland); Towler, M.R. [Inamori School of Engineering, Alfred University, Alfred, NY. 14802 (United States); Kehoe, S., E-mail: sharonkehoe@dal.ca [Department of Applied Oral Sciences, Dalhousie University, Halifax, NS, B3H 4R2 (Canada); School of Biomedical Engineering, Dalhousie University, Halifax, NS, B3H 4R2 (Canada); Boyd, D., E-mail: d.boyd@dal.ca [Department of Applied Oral Sciences, Dalhousie University, Halifax, NS, B3H 4R2 (Canada); School of Biomedical Engineering, Dalhousie University, Halifax, NS, B3H 4R2 (Canada)

    2012-08-01

    Poly (lactide-co-glycolide) (PLGA) - Pluronic F127 - glass composites have demonstrated excellent potential, from the perspective of controlled mechanical properties and cytocompatibility, for peripheral nerve regeneration. In addition to controlling the mechanical properties and cytotoxicity for such composite devices, the glass component may mediate specific responses upon implantation via degradation in the physiological environment and release of constituent elements. However, research focused on quantifying the release levels of such therapeutic ions from these experimental medical devices has been limited. To redress the balance, this paper explores the ion release profiles for Si{sup 4+}, Ca{sup 2+}, Na{sup +}, Zn{sup 2+}, and Ce{sup 4+} from experimental composite nerve guidance conduits (CNGC) comprising PLGA (at 12.5, and 20 wt.%), F127 (at 0, 2.5 and 5 wt.%) and various loadings of Si-Ca-Na-Zn-Ce glass (at 20 and 40 wt.%) for incubation periods of up to 28 days. The concentration of each ion, at various time points, was determined using Inductively Coupled Plasma-Atomic Emission Spectrometry (Perkin Elmer Optima 3000). It was observed that the Si{sup 4+}, Na{sup +}, Ca{sup 2+}, Zn{sup 2+} release from CNGCs in this study ranged from 0.22 to 6.477 ppm, 2.307 to 3.277 ppm, 40 to 119 ppm, and 45 to 51 ppm, respectively. The Ce{sup 4+} concentrations were under the minimum detection limits for the ICP instrument utilized. The results indicate that the ion release levels may be appropriate to mediate therapeutic effects with respect to peripheral nerve regeneration. The data generated in this paper provides requisite evidence to optimize composition for pre-clinical evaluation of the experimental composite. - Graphical abstract: Highlights: Black-Right-Pointing-Pointer Time-dependent degradation studies of PLGA/glass composite nerve guidance conduits (NGCs). Black-Right-Pointing-Pointer Si{sup 4+}, Na{sup +}, Ca{sup 2+} and Zn{sup 2+} release levels for the

  1. O conduto valvulado bovino contegra, um biomaterial para o tratamento cirúrgico de cardiopatias congênitas The contegra valved bovine conduit: a biomaterial for the surgical treatment of congenital heart defects

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2012-01-01

    congenital heart defects, especially as a conduit for the right ventricular outflow tract reconstruction. This article aims to make a comprehensive review on the clinical outcomes of Contegra. Reports of Contegra published since 2002 were comprehensively retrieved, collected and analyzed. There were 1718 Contegra, applied in 1705 patients. The sizes of the conduits were 8-22 mm. The patients aged from newborn to 74.5 years, prevailed by pediatrics. The primary diagnosis was congenital heart defects in all cases, with Tetralogy of Fallot, truncus arteriosus and pulmonary atresia being the first three diagnoses, representing 25.6%, 16.7%, and 13.1%, respectively. Contegra was used as a tube graft in the pulmonary position in 1635 (95.9% patients, as a monocuspid patch in 12 (0.7%, as a graft in the position of the pulmonary valve or a monocusps in 40 (2.3%, and as an inferior vena cava-pulmonary artery conduit in the Fontan procedure in 18 (1.1% patients, respectively. Conduit reimplantation was performed in 141 (8.3% patients 33.8 ± 37 (8.6-106.8 months after the initial conduit insertion. Conduit plasty was necessary in 6 (0.4%, and reintervention in 83 (4.9% patients. Indications for conduit reimplantation included severe stenosis of the distal anastomosis, pseudoaneurysm of the proximal anastomosis and severe conduit regurgitation. As for the good performance, availability and longevity, Contegra is a biomaterial suitable for the right ventricular outflow tract reconstruction and for patch repair for ventricular septal defect, but not apt for Fontan procedure.

  2. O conduto valvulado bovino contegra, um biomaterial para o tratamento cirúrgico de cardiopatias congênitas The contegra valved bovine conduit: a biomaterial for the surgical treatment of congenital heart defects

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2012-12-01

    congenital heart defects, especially as a conduit for the right ventricular outflow tract reconstruction. This article aims to make a comprehensive review on the clinical outcomes of Contegra. Reports of Contegra published since 2002 were comprehensively retrieved, collected and analyzed. There were 1718 Contegra, applied in 1705 patients. The sizes of the conduits were 8-22 mm. The patients aged from newborn to 74.5 years, prevailed by pediatrics. The primary diagnosis was congenital heart defects in all cases, with Tetralogy of Fallot, truncus arteriosus and pulmonary atresia being the first three diagnoses, representing 25.6%, 16.7%, and 13.1%, respectively. Contegra was used as a tube graft in the pulmonary position in 1635 (95.9% patients, as a monocuspid patch in 12 (0.7%, as a graft in the position of the pulmonary valve or a monocusps in 40 (2.3%, and as an inferior vena cava-pulmonary artery conduit in the Fontan procedure in 18 (1.1% patients, respectively. Conduit reimplantation was performed in 141 (8.3% patients 33.8 ± 37 (8.6-106.8 months after the initial conduit insertion. Conduit plasty was necessary in 6 (0.4%, and reintervention in 83 (4.9% patients. Indications for conduit reimplantation included severe stenosis of the distal anastomosis, pseudoaneurysm of the proximal anastomosis and severe conduit regurgitation. As for the good performance, availability and longevity, Contegra is a biomaterial suitable for the right ventricular outflow tract reconstruction and for patch repair for ventricular septal defect, but not apt for Fontan procedure.

  3. Experience de conduite, alcool et environnement monotone. In Sandrine Gaymard et Teodor Tiplica (Eds.) Sécurité routière : un défi à l'aube du XXIème siècle

    OpenAIRE

    BERTHELON, Catherine; GALY, Edith

    2017-01-01

    L'hypothèse est faite que la prise d'une faible dose d'alcool en début d'après-midi, au moment de la baisse physiologique du niveau de vigilance (creux post prandial), pourrait entraîner un assoupissement précoce, notamment chez les jeunes conducteurs novices, ayant des répercussions sur la performance. La baisse de performance devrait s'amplifier au fur et à mesure de la conduite, de par la monotonie et la longueur de la séance de conduite. Seize jeunes conducteurs de 18 ans venant d'obtenir...

  4. Pockets, conduits, channels, and plumes: links to volcanism and orogeny in the rollback dominated western Mediterranean

    Science.gov (United States)

    Miller, Meghan S.; Sun, Daoyuan; O'Driscoll, Leland; Becker, Thorsten W.; Holt, Adam; Diaz, Jordi; Thomas, Christine

    2015-04-01

    Detailed mantle and lithospheric structure from the Canary Islands to Iberia have been imaged with data from recent temporary deployments and select permanent stations from over 300 broadband seismometers. The stations extended across Morocco and Spain as part of the PICASSO, IberArray, and Morocco-Münster experiments. We present results from S receiver functions (SRF), shear wave splitting, waveform modeling, and geodynamic models that help constrain the tectonic evolution of the westernmost Mediterranean, including orogenesis of the Atlas Mountains and occurrence of localized alkaline volcanism. Our receiver function images, in agreement with previous geophysical modeling, show that the lithosphere is thin (~65 km) beneath the Atlas, but thickens (~100 km) over a very short length scale at the flanks of the mountains. We find that these dramatic changes in lithospheric thickness also correspond to dramatic decreases in delay times inferred from S and SKS splitting observations of seismic anisotropy. Pockets and conduits of low seismic velocity material below the lithosphere extend along much of the Atlas to Southern Spain and correlate with the locations of Pliocene-Quaternary magmatism. Waveform analysis from the USC linear seismic array across the Atlas Mountains constrains the position, shape, and physical characteristics of one localized, low velocity conduit that extends from the uppermost mantle (~200 km depth) up to the volcanoes in the Middle Atlas. The shape, position and temperature of these seismically imaged low velocity anomalies, topography of the base of the lithosphere, morphology of the subducted slab beneath the Alboran Sea, position of the West African Craton and correlation with mantle flow inferred from shear wave splitting suggest that the unusually high topography of the Atlas Mountains and isolated recent volcanics are due to active mantle support that may be from material channeled from the Canary Island plume.

  5. Solid-cryogen-stabilized, cable-in-conduit (CIC) superconducting cables

    Science.gov (United States)

    Voccio, J. P.; Michael, P. C.; Bromberg, L.; Hahn, S.

    2015-12-01

    This paper considers the use of a solid cryogen as a means to stabilize, both mechanically and thermally, magnesium diboride (MgB2) superconducting strands within a dual-channel cable-in-conduit (CIC) cable for use in AC applications, such as a generator stator winding. The cable consists of two separate channels; the outer channel contains the superconducting strands and is filled with a fluid (liquid or gas) that becomes solid at the device operating temperature. Several options for fluid will be presented, such as liquid nitrogen, hydrocarbons and other chlorofluorocarbons (CFCs) that have a range of melting temperatures and volumetric expansions (from solid at operating temperature to fixed volume at room temperature). Implications for quench protection and conductor stability, enhanced through direct contact with the solid cryogen, which has high heat capacity and thermal conductivity (compared with helium gas), will be presented. Depending on the cryogen, the conductor will be filled initially either with liquid at atmospheric conditions or a gas at high pressure (∼100 atm). After cooldown, the cryogen in the stranded-channel will be solid, essentially locking the strands in place, preventing strand motion and degradation due to mechanical deformation while providing enhanced thermal capacity for stability and protection. The effect of cryogen porosity is also considered. The relatively high heat capacity of solid cryogens at these lower temperatures (compared to gaseous helium) enhances the thermal stability of the winding. During operation, coolant flow through the open inner channel will minimize pressure drop.

  6. The Himalayas: barrier and conduit for gene flow.

    Science.gov (United States)

    Gayden, Tenzin; Perez, Annabel; Persad, Patrice J; Bukhari, Areej; Chennakrishnaiah, Shilpa; Simms, Tanya; Maloney, Trisha; Rodriguez, Kristina; Herrera, Rene J

    2013-06-01

    The Himalayan mountain range is strategically located at the crossroads of the major cultural centers in Asia, the Middle East and Europe. Although previous Y-chromosome studies indicate that the Himalayas served as a natural barrier for gene flow from the south to the Tibetan plateau, this region is believed to have played an important role as a corridor for human migrations between East and West Eurasia along the ancient Silk Road. To evaluate the effects of the Himalayan mountain range in shaping the maternal lineages of populations residing on either side of the cordillera, we analyzed mitochondrial DNA variation in 344 samples from three Nepalese collections (Newar, Kathmandu and Tamang) and a general population of Tibet. Our results revealed a predominantly East Asian-specific component in Tibet and Tamang, whereas Newar and Kathmandu are both characterized by a combination of East and South Central Asian lineages. Interestingly, Newar and Kathmandu harbor several deep-rooted Indian lineages, including M2, R5, and U2, whose coalescent times from this study (U2, >40 kya) and previous reports (M2 and R5, >50 kya) suggest that Nepal was inhabited during the initial peopling of South Central Asia. Comparisons with our previous Y-chromosome data indicate sex-biased migrations in Tamang and a founder effect and/or genetic drift in Tamang and Newar. Altogether, our results confirm that while the Himalayas acted as a geographic barrier for human movement from the Indian subcontinent to the Tibetan highland, it also served as a conduit for gene flow between Central and East Asia. Copyright © 2013 Wiley Periodicals, Inc.

  7. Chilling of Dormant Buds Hyperinduces FLOWERING LOCUS T and Recruits GA-Inducible 1,3-β-Glucanases to Reopen Signal Conduits and Release Dormancy in Populus[W][OA

    Science.gov (United States)

    Rinne, Päivi L.H.; Welling, Annikki; Vahala, Jorma; Ripel, Linda; Ruonala, Raili; Kangasjärvi, Jaakko; van der Schoot, Christiaan

    2011-01-01

    In trees, production of intercellular signals and accessibility of signal conduits jointly govern dormancy cycling at the shoot apex. We identified 10 putative cell wall 1,3-β-glucanase genes (glucan hydrolase family 17 [GH17]) in Populus that could turn over 1,3-β-glucan (callose) at pores and plasmodesmata (PD) and investigated their regulation in relation to FT and CENL1 expression. The 10 genes encode orthologs of Arabidopsis thaliana BG_ppap, a PD-associated glycosylphosphatidylinositol (GPI) lipid-anchored protein, the Arabidopsis PD callose binding protein PDCB, and a birch (Betula pendula) putative lipid body (LB) protein. We found that these genes were differentially regulated by photoperiod, by chilling (5°C), and by feeding of gibberellins GA3 and GA4. GA3 feeding upregulated all LB-associated GH17s, whereas GA4 upregulated most GH17s with a GPI anchor and/or callose binding motif, but only GA4 induced true bud burst. Chilling upregulated a number of GA biosynthesis and signaling genes as well as FT, but not CENL1, while the reverse was true for both GA3 and GA4. Collectively, the results suggest a model for dormancy release in which chilling induces FT and both GPI lipid-anchored and GA3-inducible GH17s to reopen signaling conduits in the embryonic shoot. When temperatures rise, the reopened conduits enable movement of FT and CENL1 to their targets, where they drive bud burst, shoot elongation, and morphogenesis. PMID:21282527

  8. Conduits to care: call lights and patients’ perceptions of communication

    Science.gov (United States)

    Montie, Mary; Shuman, Clayton; Galinato, Jose; Patak, Lance; Anderson, Christine A; Titler, Marita G

    2017-01-01

    Background Call light systems remain the primary means of hospitalized patients to initiate communication with their health care providers. Although there is vast amounts of literature discussing patient communication with their health care providers, few studies have explored patients’ perceptions concerning call light use and communication. The specific aim of this study was to solicit patients’ perceptions regarding their call light use and communication with nursing staff. Methods Patients invited to this study met the following inclusion criteria: proficient in English, been hospitalized for at least 24 hours, aged ≥21 years, and able to communicate verbally (eg, not intubated). Thirty participants provided written informed consent, were enrolled in the study, and completed interviews. Results Using qualitative descriptive methods, five major themes emerged from patients’ perceptions (namely; establishing connectivity, participant safety concerns, no separation: health care and the call light device, issues with the current call light, and participants’ perceptions of “nurse work”). Multiple minor themes supported these major themes. Data analysis utilized the constant comparative methods of Glaser and Strauss. Discussion Findings from this study extend the knowledge of patients’ understanding of not only why inconsistencies occur between the call light and their nurses, but also why the call light is more than merely a device to initiate communication; rather, it is a direct conduit to their health care and its delivery. PMID:29075125

  9. Conduits to care: call lights and patients' perceptions of communication.

    Science.gov (United States)

    Montie, Mary; Shuman, Clayton; Galinato, Jose; Patak, Lance; Anderson, Christine A; Titler, Marita G

    2017-01-01

    Call light systems remain the primary means of hospitalized patients to initiate communication with their health care providers. Although there is vast amounts of literature discussing patient communication with their health care providers, few studies have explored patients' perceptions concerning call light use and communication. The specific aim of this study was to solicit patients' perceptions regarding their call light use and communication with nursing staff. Patients invited to this study met the following inclusion criteria: proficient in English, been hospitalized for at least 24 hours, aged ≥21 years, and able to communicate verbally (eg, not intubated). Thirty participants provided written informed consent, were enrolled in the study, and completed interviews. Using qualitative descriptive methods, five major themes emerged from patients' perceptions (namely; establishing connectivity, participant safety concerns, no separation: health care and the call light device, issues with the current call light, and participants' perceptions of "nurse work"). Multiple minor themes supported these major themes. Data analysis utilized the constant comparative methods of Glaser and Strauss. Findings from this study extend the knowledge of patients' understanding of not only why inconsistencies occur between the call light and their nurses, but also why the call light is more than merely a device to initiate communication; rather, it is a direct conduit to their health care and its delivery.

  10. Structure Of Conduits Of The Acidic Volcanism And Related Deposits In The Paraná-Etendeka Magmatic Province, São Marcos Region, South Brazil

    Science.gov (United States)

    Guimarães, L. F.; De Campos, C. P.; Lima, E. F. D.; Janasi, V. A.

    2015-12-01

    Voluminous acidic volcanics from the Paraná-Etendeka Magmatic Province crop out in the southern part of Brazil. The conduits responsible for the feeding of this intermediate/acid volcanism are preserved and well exposed in the São Marcos region (Lima et al. 2012; Geologia USP 12:49-64). Conduits are aligned along a NW-SE trend and have thicknesses up to 1 km. These structures are often characterized by mixing between dacitic and rhyodacitic magmas, with intercalation between two major zones: 1) reddish or grayish vitrophiricdacite/rhyodacite, sub-divided in massive or vesiculated; 2) reddish or grayish vitrophiric fragmented dacite/rhyodacite composed of bubble-rich angular to rounded blocks. Such fragments commonly deform coeval to the flow. A third zone dominated by filaments depicts a chaotic stretching-and-folding process from the mixture of the acid magmas. We used classical field measurements of flow structures and recognized main flow directions in these feeder-dikes. They follow two preferential directions: NW, ranging from N272° to N 355°, and NE, varying from N20° to N85°. These directions are indicative of a transtensive fissural system, which seems to be related to conjugated fractures. Evidence of an important fragmentation process in the conduits point towards the presence of related products in this region, thus rheomorphic deposits such as those observed elsewhere (e.g. Uruguay and Namibia) are expected to occur. Possible vestiges of these deposits could be represented by restricted outcrops of lens-shaped and banded hipohyaline, occasionally bubble-rich, dacites. The presence of continuous pseudotachylitic levels, tightly folded bands with horizontal axial planes together with local deformed bubble-rich pumice-like lens could be indicative of remelting and rheomorphism of previous vulcanoclastic material. Coulees and compound (lobed) dacitic lava flows, reaching up to 5-8 meters length, occur as the uppermost deposits and correspond to the

  11. [Laparoscopic cystectomy and ileal conduit urinary diversion for neurogenic bladders and related conditions. Morbidity and better quality of life].

    Science.gov (United States)

    Sakhri, R; Seigle-Murandi, F; Jacqmin, D; Lang, H; Saussine, C

    2015-05-01

    To assess morbidity and functional consequences of laparoscopic cystectomy with ileal conduit urinary diversion: in neurologic patients. We reviewed the records of forty-two patients (ten men and thirty-two women) who underwent surgery between August 2007 and October 2013. The median age of the patient was 54 years old (range between 21-79 years). A laparoscopic cystectomy was performed followed by a short laparotomy to perform the ileal conduit urinary diversion. Records were reviewed to retrieve the indications and describe the postoperative and functional course. Patients and GPs were interviewed during phone calls to appreciate the quality of life by the PGII scale in order to assess the functional outcome. The operation was performed on 42 patients, of whom 18 had multiple sclerosis, nine a post-traumatic neurogenic bladder. Among the total population, 10 patients (23.81%) required a transfusion of at least one packed red blood cells (1-7). The overall rate of early complications was 35.71%. Belated complications were seen in 52.38% of the population. The median duration of hospital stay was 16 days (range between 9-70 days). The median follow up was 34 months (range between 1-76 months). For patients, the PGII scale rating had a median value of 6 (2-7). All referring physicians described a better functional status. The laparoscopic cystectomy can make postoperative course smoother for the neurological patients. However, the surgeon must weigh individually the benefit of performing the operation. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  12. A novel approach to estimate the eruptive potential and probability in open conduit volcanoes.

    Science.gov (United States)

    De Gregorio, Sofia; Camarda, Marco

    2016-07-26

    In open conduit volcanoes, volatile-rich magma continuously enters into the feeding system nevertheless the eruptive activity occurs intermittently. From a practical perspective, the continuous steady input of magma in the feeding system is not able to produce eruptive events alone, but rather surplus of magma inputs are required to trigger the eruptive activity. The greater the amount of surplus of magma within the feeding system, the higher is the eruptive probability.Despite this observation, eruptive potential evaluations are commonly based on the regular magma supply, and in eruptive probability evaluations, generally any magma input has the same weight. Conversely, herein we present a novel approach based on the quantification of surplus of magma progressively intruded in the feeding system. To quantify the surplus of magma, we suggest to process temporal series of measurable parameters linked to the magma supply. We successfully performed a practical application on Mt Etna using the soil CO2 flux recorded over ten years.

  13. Normal zone propagation and Thermal Hydraulic Quenchback in a cable-in-conduit superconductor

    International Nuclear Information System (INIS)

    Lue, J.W.; Dresner, L.

    1993-01-01

    When a local normal zone appears in a cable-in-conduit superconductor, a slug of hot helium is produced. The pressure rises and the hot helium expands. Thus the normal zone propagation in such a conductor can be governed by the hot helium expansion, rather than the heat conduction along the conductor. The expansion of the hot helium compresses the cold helium outside of the normal zone. This raises th at sign temperature of the cold helium. When the temperature rise reaches the current sharing limit, the superconductor in contact goes normal. Thus a rapid increase in normal zone propagation occur. This phenomenon is termed Thermal Hydraulic Quenchback (THQ). An experiment was performed to investigate this process. The existence of THQ was verified. Thresholds of THQ were also observed by varying the conductor current, the magnetic field, the temperature, and the initial normal zone length. When THQ occurred, normal zone propagation approaching the velocity of sound was observed. A better picture of THQ is obtained by a careful comparison of the data with analytical studies

  14. Contention between supply of hydrothermal fluid and conduit obstruction: inferences from numerical simulations

    Science.gov (United States)

    Tanaka, Ryo; Hashimoto, Takeshi; Matsushima, Nobuo; Ishido, Tsuneo

    2018-05-01

    We investigate a volcanic hydrothermal system using numerical simulations, focusing on change in crater temperature. Both increases and decreases in crater temperature have been observed before phreatic eruptions. We follow the system's response for up to a decade after hydrothermal fluid flux from the deep part of the system is increased and permeability is reduced at a certain depth in a conduit. Our numerical simulations demonstrate that: (1) changes in crater temperature are controlled by the magnitude of the increase in hydrothermal fluid flux and the degree of permeability reduction; (2) significant increases in hydrothermal flux with decreases in permeability induce substantial pressure changes in shallow depths in the edifice and decreases in crater temperature; (3) the location of maximum pressure change differs between the mechanisms. The results of this study imply that it is difficult to predict eruptions by crater temperature change alone. One should be as wary of large eruptions when crater temperature decreases as when crater temperature increases. It is possible to clarify the implications of changes in crater temperature with simultaneous observation of ground deformation.

  15. An international multicenter study comparing arrhythmia prevalence between the intracardiac lateral tunnel and the extracardiac conduit type of Fontan operations.

    Science.gov (United States)

    Balaji, Seshadri; Daga, Ankana; Bradley, David J; Etheridge, Susan P; Law, Ian H; Batra, Anjan S; Sanatani, Shubayan; Singh, Anoop K; Gajewski, Kelly K; Tsao, Sabrina; Singh, Harinder R; Tisma-Dupanovic, Svjetlana; Tateno, Shigeru; Takamuro, Motoki; Nakajima, Hiromichi; Roos-Hesselink, Jolien W; Shah, Maully

    2014-08-01

    The study objective was to determine whether the extracardiac conduit Fontan confers an arrhythmia advantage over the intracardiac lateral tunnel Fontan. This multicenter study of 1271 patients compared bradyarrhythmia (defined as need for pacing) and tachyarrhythmia (defined as needing antiarrhythmic therapy) between 602 patients undergoing the intracardiac Fontan and 669 patients undergoing the extracardiac Fontan. The median age at the time of the Fontan procedure was 2.1 years (interquartile range, 1.6-3.2 years) for the intracardiac group and 3.0 years (interquartile range, 2.4-3.9) for the extracardiac group (P 30 days) bradyarrhythmia occurred in 105 patients (18%) in the intracardiac group and 63 patients (9%) in the extracardiac group (P 30 days) tachyarrhythmia occurred in 58 patients (10%) in the intracardiac group and 23 patients (3%) in the extracardiac group (P factoring time since surgery, more patients in the extracardiac group had early bradycardia (odds ratio, 2.9; 95% confidence interval, 1.8-4.6), with no difference in early tachycardia, late bradycardia, or late tachycardia. Overall arrhythmia burden is similar between the 2 groups, but the extracardiac Fontan group had a higher incidence of early bradyarrhythmias. There was no difference in the incidence of late tachyarrhythmias over time between the 2 operations. Therefore, the type of Fontan performed should be based on factors other than an anticipated reduction in arrhythmia burden from the extracardiac conduit. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  16. Exploring the role of lipids in intercellular conduits: breakthroughs in the pipeline

    Directory of Open Access Journals (Sweden)

    Elise eDelage

    2013-12-01

    Full Text Available It has been known for more than a century that most of the plant cells are connected to their neighbors through membranous pores perforating the cell wall, namely plasmodesmata (PDs. The recent discovery of tunneling nanotubes (TNTs, thin membrane bridges established between distant mammalian cells, suggests that intercellular communication mediated through cytoplasmic continuity could be a conserved feature of eukaryotic organisms. Although TNTs differ from PDs in their formation and architecture, both are characterized by a continuity of the plasma membrane between two cells, delimiting a nanotubular channel supported by actin-based cytoskeleton. Due to this unusual membrane organization, lipids are likely to play critical roles in the formation and stability of intercellular conduits like TNTs and PDs, but also in regulating the transfer through these structures. While it is crucial for a better understanding of those fascinating communication highways, the study of TNT lipid composition and dynamics turned out to be extremely challenging. The present review aims to give an overview of the recent findings in this context. We will also discuss some of the promising imaging approaches, which might be the key for future breakthroughs in the field and could also benefit the research on PDs.

  17. The side-to-side fashion for individual distal coronary anastomosis using venous conduit.

    Science.gov (United States)

    Kato, Takayoshi; Tsunekawa, Tomohiro; Motoji, Yusuke; Hirakawa, Akihiro; Okawa, Yasuhide; Tomita, Shinji

    2017-04-01

    Regarding to coronary artery bypass grafting (CABG), the end-to-side anastomosis (ESA) has been performed as a gold standard. Recently, the effectiveness of the distal side-to-side anastomosis (SSA) in CABG using internal mammary artery has been reported. The benefit of SSA comparing to ESA also has been disclosed by computing simulation. However, use of SSA by venous conduit for individual CABG has not been reported. In this study, we investigated feasibility of SSA. From January 2013 to October 2014, we conducted 114 CABGs. There were 92 venous distal anastomoses without sequential anastomotic site (61 SSA and 31 ESA). The anastomosis was evaluated before discharge and at 1 year after the procedure by angiography or multi-detector row computed tomographic coronary angiography. The median values for time to anastomosis were 13 min in the two group (p = 0.89). There was no revision of anastomosis in both groups. Additional stitches for hemostasis were required significantly less in SSA than ESA (18.0 vs 45.2 %, respectively, p fashion is easy to perform and maybe beneficial in blood flow pattern.

  18. Multicriteria Gain Tuning for Rotorcraft Flight Controls (also entitled The Development of the Conduit Advanced Control System Design and Evaluation Interface with a Case Study Application Fly by Wire Helicopter Design)

    Science.gov (United States)

    Biezad, Daniel

    1997-01-01

    Handling qualities analysis and control law design would seem to be naturally complimenting components of aircraft flight control system design, however these two closely coupled disciplines are often not well integrated in practice. Handling qualities engineers and control system engineers may work in separate groups within an aircraft company. Flight control system engineers and handling quality specialists may come from different backgrounds and schooling and are often not aware of the other group's research. Thus while the handling qualities specifications represent desired aircraft response characteristics, these are rarely incorporated directly in the control system design process. Instead modem control system design techniques are based on servo-loop robustness specifications, and simple representations of the desired control response. Comprehensive handling qualities analysis is often left until the end of the design cycle and performed as a check of the completed design for satisfactory performance. This can lead to costly redesign or less than satisfactory aircraft handling qualities when the flight testing phase is reached. The desire to integrate the fields of handling qualities and flight,control systems led to the development of the CONDUIT system. This tool facilitates control system designs that achieve desired handling quality requirements and servo-loop specifications in a single design process. With CONDUIT, the control system engineer is now able to directly design and control systems to meet the complete handling specifications. CONDUIT allows the designer to retain a preferred control law structure, but then tunes the system parameters to meet the handling quality requirements.

  19. Ecoulements intermittents de gaz et de liquide en conduite verticale Intermittent Gas and Liquid Flows in a Vertical Pipe.

    Directory of Open Access Journals (Sweden)

    Line A.

    2006-11-01

    Full Text Available Le modèle présenté ici permet la pré-détermination du gradient de pression, du taux global de gaz, et de grandeurs caractéristiques de l'intermittence, dans un écoulement à poches et bouchons en conduite verticale. L'écriture des lois de conservation en moyenne phasique conditionnelle conduit à la définition d'une cellule moyenne équivalente. La fermeture du modèle est assurée par des lois de contrainte de cisaillement film-paroi, film-poche, bouchon-paroi, par une loi d'arrachage du gaz au culot de la poche, une loi de glissement du gaz dans les bouchons et par une loi de la vitesse moyenne de propagation des fronts de poches. Le calibrage et la qualification du modèle s'appuient sur deux banques de données, dont l'une a été obtenue avec des fluides pétroliers dans des conditions proches des situations industrielles (boucle diphasique de Boussens. The model described here can be used to predetermine the pressure gradient, the overall gas rate and the characteristic intermittence magnitudes in pocket and slug flow in a vertical pipe. The way governing equations in the conditional phase average are written defines an equivalent average cell. The model is closed by film/wall, film/pocket and slug/wall shear-stress laws, by a pulloff law for the gas at the bottom of the pocket, a slippage law for the gas in the slugs, and a mean propagation velocity law for the pocket fronts. The calibration and qualification of the model are based on two data banks, one of which contains data on petroleum fluids under conditions close to industrial situations (two-phase loop at Boussens.

  20. A Decaheme Cytochrome as a Molecular Electron Conduit in Dye-Sensitized Photoanodes

    Science.gov (United States)

    Hwang, Ee Taek; Sheikh, Khizar; Orchard, Katherine L; Hojo, Daisuke; Radu, Valentin; Lee, Chong-Yong; Ainsworth, Emma; Lockwood, Colin; Gross, Manuela A; Adschiri, Tadafumi; Reisner, Erwin; Butt, Julea N; Jeuken, Lars J C

    2015-01-01

    In nature, charge recombination in light-harvesting reaction centers is minimized by efficient charge separation. Here, it is aimed to mimic this by coupling dye-sensitized TiO2 nanocrystals to a decaheme protein, MtrC from Shewanella oneidensis MR-1, where the 10 hemes of MtrC form a ≈7-nm-long molecular wire between the TiO2 and the underlying electrode. The system is assembled by forming a densely packed MtrC film on an ultra-flat gold electrode, followed by the adsorption of approximately 7 nm TiO2 nanocrystals that are modified with a phosphonated bipyridine Ru(II) dye (RuP). The step-by-step construction of the MtrC/TiO2 system is monitored with (photo)electrochemistry, quartz-crystal microbalance with dissipation (QCM-D), and atomic force microscopy (AFM). Photocurrents are dependent on the redox state of the MtrC, confirming that electrons are transferred from the TiO2 nanocrystals to the surface via the MtrC conduit. In other words, in these TiO2/MtrC hybrid photodiodes, MtrC traps the conduction-band electrons from TiO2 before transferring them to the electrode, creating a photobioelectrochemical system in which a redox protein is used to mimic the efficient charge separation found in biological photosystems. PMID:26180522

  1. Thermo-Hydraulic behaviour of dual-channel superconducting Cable-In-Conduit Conductors for ITER

    International Nuclear Information System (INIS)

    Renard, B.

    2006-09-01

    In an effort to optimise the cryogenics of large superconducting coils for fusion applications (ITER), dual channel Cable-In-Conduit Conductors (CICC) are designed with a central channel spiral to provide low hydraulic resistance and faster helium circulation. The qualitative and economic rationale of the conductor central channel is here justified to limit the superconductor temperature increase, but brings more complexity to the conductor cooling characteristics. The pressure drop of spirals is experimentally evaluated in nitrogen and water and an explicit hydraulic friction model is proposed. Temperatures in the cable must be quantified to guarantee superconductor margin during coil operation under heat disturbance and set adequate inlet temperature. Analytical one-dimensional thermal models, in steady state and in transient, allow to better understand the thermal coupling of CICC central and annular channels. The measurement of a heat transfer characteristic space and time constants provides cross-checking experimental estimations of the internal thermal homogenization. A simple explicit model of global inter-channel heat exchange coefficient is proposed. The risk of thermosyphon between the two channels is considered since vertical portions of fusion coils are subject to gravity. The new hydraulic model, heat exchange model and gravitational risk ratio allow the thermohydraulic improvement of CICC central spirals. (author)

  2. Study on the dynamic behavior of a current in cable-in-conduit conductors by using self magnetic field measurements

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki 509-5292, Gifu (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Imagawa, Shinsaku; Mito, Toshiyuki [National Institute for Fusion Science, 322-6 Oroshi, Toki 509-5292, Gifu (Japan); Kizu, Kaname; Murakami, Haruyuki; Yoshida, Kiyoshi [Japan Atomic Energy Agency, Ibaraki (Japan)

    2011-10-15

    In order to understand the current behavior inside a cable-in-conduit conductor (CICC), self magnetic field measurements on the CICC were conducted. A prototype NbTi CICC, the configuration of which is a racket shape, for JT-60SA EF coil was used as a short conductor sample. By using Hall sensors arranged around the short conductor sample, the variation in the self magnetic field was measured. Taking into account the measurements, the current behavior inside the CICC was analyzed by using analytical models consisting of line currents. The analytical results indicate that the current distribution in the cross-section of the CICC would be non-uniform before a normal propagation, and the current distribution would be improved after the normal propagation.

  3. Literature Review: Double-Barrelled Wet Colostomy (One Stoma) versus Ileal Conduit with Colostomy (Two Stomas).

    Science.gov (United States)

    Gan, Jason; Hamid, Rizwan

    2017-01-01

    The aim of this literature review was to analyse the advantages and disadvantages of a traditional ileal conduit (IC) with separate colostomy technique compared to the outcomes of a double-barrelled wet colostomy (DBWC) technique. The former technique results in the formation of two stomas, and the latter results in the formation of one stoma. PubMed was searched electronically for articles on DBWC. Fifteen articles were retrieved and of them 13 were included in the literature review (350 patients). Of the articles, 3 directly compared DBWC to IC with colostomy. Review of 13 DBWC articles demonstrated perioperative mortality ranging between 0 and 11.1% and postoperative complications ranging from 0 to 100%. Three of the studies directly compared DBWC to IC with colostomy; median operating times and length of stay were shorter in DBWC patients (p colostomy technique, as it requires only one stoma. This literature review supports the use of the technically less challenging DBWC technique as a viable alternative to the traditional IC with colostomy technique. © 2016 S. Karger AG, Basel.

  4. Glacier surge mechanism based on linked cavity configuration of the basal water conduit system

    Science.gov (United States)

    Kamb, Barclay

    1987-08-01

    Based on observations of the 1982-1983 surge of Variegated Glacier, Alaska, a model of the surge mechanism is developed in terms of a transition from the normal tunnel configuration of the basal water conduit system to a linked cavity configuration that tends to restrict the flow of water, resulting in increased basal water pressures that cause rapid basal sliding. The linked cavity system consists of basal cavities formed by ice-bedrock separation (cavitation), ˜1 m high and ˜10 m in horizontal dimensions, widely scattered over the glacier bed, and hydraulically linked by narrow connections where separation is minimal (separation gap ≲ 0.1 m). The narrow connections, called orifices, control the water flow through the conduit system; by throttling the flow through the large cavities, the orifices keep the water flux transmitted by the basal water system at normal levels even though the total cavity cross-sectional area (˜200 m2) is much larger than that of a tunnel system (˜10 m2). A physical model of the linked cavity system is formulated in terms of the dimensions of the "typical" cavity and orifice and the numbers of these across the glacier width. The model concentrates on the detailed configuration of the typical orifice and its response to basal water pressure and basal sliding, which determines the water flux carried by the system under given conditions. Configurations are worked out for two idealized orifice types, step orifices that form in the lee of downglacier-facing bedrock steps, and wave orifices that form on the lee slopes of quasisinusoidal bedrock waves and are similar to transverse "N channels." The orifice configurations are obtained from the results of solutions of the basal-sliding-with-separation problem for an ice mass constituting of linear half-space of linear rheology, with nonlinearity introduced by making the viscosity stress-dependent on an intuitive basis. Modification of the orifice shapes by melting of the ice roof due to

  5. Conduits to care: call lights and patients’ perceptions of communication

    Directory of Open Access Journals (Sweden)

    Montie M

    2017-09-01

    Full Text Available Mary Montie,1 Clayton Shuman,1 Jose Galinato,1 Lance Patak,2 Christine A Anderson,1 Marita G Titler1 1Department of Systems, Populations, and Leadership, School of Nursing, University of Michigan, Ann Arbor, MI, 2Department of Anesthesiology and Pain Medicine, Seattle Children’s Hospital, Seattle, WA, USA Background: Call light systems remain the primary means of hospitalized patients to initiate communication with their health care providers. Although there is vast amounts of literature discussing patient communication with their health care providers, few studies have explored patients’ perceptions concerning call light use and communication. The specific aim of this study was to solicit patients’ perceptions regarding their call light use and communication with nursing staff. Methods: Patients invited to this study met the following inclusion criteria: proficient in English, been hospitalized for at least 24 hours, aged ≥21 years, and able to communicate verbally (eg, not intubated. Thirty participants provided written informed consent, were enrolled in the study, and completed interviews. Results: Using qualitative descriptive methods, five major themes emerged from patients’ perceptions (namely; establishing connectivity, participant safety concerns, no separation: health care and the call light device, issues with the current call light, and participants’ perceptions of “nurse work”. Multiple minor themes supported these major themes. Data analysis utilized the constant comparative methods of Glaser and Strauss. Discussion: Findings from this study extend the knowledge of patients’ understanding of not only why inconsistencies occur between the call light and their nurses, but also why the call light is more than merely a device to initiate communication; rather, it is a direct conduit to their health care and its delivery. Keywords: nurse–patient communication, medical technology, quality of care, qualitative research

  6. Results of a Seven-Year, Single-Centre Experience of the Long-Term Outcomes of Bovine Ureter Grafts Used as Novel Conduits for Haemodialysis Fistulas

    International Nuclear Information System (INIS)

    Das, Neelan; Bratby, Mark J.; Shrivastava, Vivek; Cornall, Alison J.; Darby, Christopher R.; Boardman, Philip; Anthony, Susan; Uberoi, Raman

    2011-01-01

    Purpose: To report the long-term outcomes of bovine ureter grafts as novel conduits for haemodialysis fistulas. Materials and Methods: Thirty-five patients underwent placement of a total of 40 SynerGraft 100 (SG100; CryoLife Europa ® , Guildford, UK) bovine ureter grafts between April 2002 and February 2009. Prospective data were collected on all patients, including active surveillance with blood flow studies and 6-monthly duplex ultrasound studies. Main outcome measures were primary and secondary patency rates. Results: Mean follow-up time was 97 weeks (range 4–270). Thirteen patients died from unrelated causes during the study period; 12 of these patients had a functioning graft at the time of death. Five patients underwent transplantation, and all had a functioning graft at transplantation. Twelve patients had a functioning graft at the end of the study period. One hundred and ten stenoses were detected, and 97 venoplasty procedures were performed. Of the stenoses, 41.8% were located at the venous anastomosis, 12.7% within the graft, 17.3% in the outflow veins, and 28.1% in central veins. No arterial stenoses were detected. Primary patency rates were 53% at 6 months and 14% at 1 year. Secondary patency rates were 81% at 6 months, 75% at 1 year, and 56% at 2 years. Conclusions: Active surveillance and intervention was able to achieve satisfactory long-term secondary patency for these novel conduits compared with those made of PTFE seen in other studies.

  7. Comportement comparé de conduites rigides et flexibles ensouillées au voisinage de sols gelés Comparative Behavior of Rigid and Flexible Pipes Buried in the Vicinity of Frozen Ground

    Directory of Open Access Journals (Sweden)

    Putot C.

    2006-11-01

    Full Text Available Au cours des dernières années, les activités pétrolières à terre comme en mer, tant en Alaska qu'au Canada, se sont maintenues à un niveau raisonnable. En octobre 1987, le premier champ pétrolier offshore a été mis en exploitation en mer de Beaufort (Endicott. Bien que l'industrie soit principalement dans une phase d'exploration, des besoins vont progressivement se manifester en matière de lignes de collecte et d'injection. La détermination du tracé de conduites en offshore arctique ainsi que leur dimensionnement nécessite la prise en compte de facteurs très spécifiques : le raclage des glaces dérivantes impose une profondeur minimum d'ensouillage, ce qui accroît, malgré l'isolation des conduites, la proportion de chaleur communiquée au pergélisol (ou permafrost en dégel : les tassements différentiels résultant de la variabilité de composition des sols peuvent provoquer des déformations, voire des instabilités des conduites tout à fait inacceptables. Il est assez intuitif de penser que les conduites flexibles accommoderont plus facilement les mouvements de sol que les rigides. L'objet de cet article est de proposer une méthode d'analyse assez souple permettant de jauger facilement cet avantage. In recent years, onshore and offshore petroleum activities, in both Alaska and Canada, have continued on a reasonable level. In October 1987 the first offshore oil field began production in the Beaufort Sea (Endicott. Although the industry is mainly in an exploration phase, needs will steadily appear with regard to gathering and injection line. . The determination to lay flowlines in offshore arctic areas as well as their sizing require that very specific factors be taken into consideration. Scouring by drifting ice requires a minimum depth of burial. Despite the insulation of pipes, this burial increases the proportion of heat communicated to melting permafrost. The differential compaction resulting from the variability of

  8. Ecoulements diphasiques gaz-liquide à poches et à bouchons en conduites Two-Phase Gas-Liquid Slug Flow in Pipes

    Directory of Open Access Journals (Sweden)

    Ferschneider G.

    2006-11-01

    Full Text Available Les écoulements diphasiques gaz-liquide ont été étudiés afin de contribuer à développer des modèles de calculs prédictifs des pertes de charge dans les conduites de production des bruts pétroliers. Les expériences nécessaires ont été réalisées sur la boucle diphasique de Boussens dans les conditions suivantes représentatives des conditions industrielles : diamètre 6 , longueur 120 m, disposition de la conduite horizontale ou faiblement ascendante, couple de fluide gaz naturel-huile légère. Le gradient de pression, le contenu global, et la distribution locale des phases ont été mesurés. Le traitement des équations de conservation phasique intégrées sur la section par différents types de moyennes a permis de développer un modèle cellulaire qui inclue un nombre limité d'équations constitutives nécessaires à sa fermeture. Ce modèle prédétermine convenablement le gradient de pression, le contenu gaz global et la longueur des poches et des bouchons. Two-phase gas-liquid flows were analyzed so as to develop models for prediction of pressure drops in crude-oil production lines. The experiments were performed on the two-phase loop at Boussens under the following representative industrial conditions: 6 diameter, 120 m length, horizontal or slightly rising pipe, couple of fluids natural gas and light oil. The pressure gradient, average content and local phase distribution were measured. Conservation phase equations integrated along the cross-section were processed by different time-averaged operators so as to develop a cellular model including a limited number of constitutive equations required for its closure. This model suitably predetermines the pressure gradient, the average gas content and the length of gas and liquid slug.

  9. Churn-annular flow pattern transition in a vertical upward gas-liquid two-phase flow in various conduits

    International Nuclear Information System (INIS)

    Takenaka, Nobuyuki; Ueda, Tadanobu; Asano, Hitoshi

    2008-01-01

    Void fraction was measured by neutron radiography for a vertical upward gas-water two-phase flow in a concentric annular tube with and with out a spacer, 4x4 rod bundle with and without a spacer and a tight rod bundle with and without a wrapping wire for various gas and liquid flow rates. The flow patterns of these two-phase flows were determined by the Mishima-Ishii flow pattern map and void fraction was calculated by the Ishii's drift flux model. The predicted values were compared with the experimental results. The void fraction was well predicted by the Mishima-Ishii flow pattern map and the Ishii's drift flux model except the annular flow region with void fraction lower than 0.8 for conduits with small equivalent diameter. A new churn-annular flow pattern transition condition of the void fraction equal to 0.8 was added. The void fraction for the present experimental condition was successful predicted with the new transition model. (author)

  10. Helium flow dynamics and heat transfer in a cable in conduit conductor of superconducting magnets: a review

    International Nuclear Information System (INIS)

    Vaghela, Hitensinh; Sarkar, Biswanath; Lakhera, Vikas

    2016-01-01

    Superconducting (SC) magnets with Cable in Conduit Conductor (CICC) winding, cooled by helium at 4 K temperature are employed for many applications which require high magnetic field and high current densities. The construction of CICC aims to maintain superconductivity state by optimization of various parameters, i.e., thermal stability, ratio of normal conductor to superconductor material, mechanical strength, low hydraulic impedance, current density, magnetic field, etc. The cryogenic thermal stability of the CICC is of prime importance for the safe, stable and reliable operation of SC magnets. The prediction of thermal and hydraulic behaviour of CICC in large SC magnets is difficult due to the complex geometry, variation of fluid properties, various heat in-flux incidences over the long length of CICC and a complex heat transport phenomenon. A systematic review of the thermal and hydraulic studies of CICC has been presented in the paper highlighting the challenges and opportunities for further improvement in its design and performance. (author)

  11. Kinking and Torsion Can Significantly Improve the Efficiency of Valveless Pumping in Periodically Compressed Tubular Conduits. Implications for Understanding of the Form-Function Relationship of Embryonic Heart Tubes

    Directory of Open Access Journals (Sweden)

    Florian Hiermeier

    2017-11-01

    Full Text Available Valveless pumping phenomena (peristalsis, Liebau-effect can generate unidirectional fluid flow in periodically compressed tubular conduits. Early embryonic hearts are tubular conduits acting as valveless pumps. It is unclear whether such hearts work as peristaltic or Liebau-effect pumps. During the initial phase of its pumping activity, the originally straight embryonic heart is subjected to deforming forces that produce bending, twisting, kinking, and coiling. This deformation process is called cardiac looping. Its function is traditionally seen as generating a configuration needed for establishment of correct alignments of pulmonary and systemic flow pathways in the mature heart of lung-breathing vertebrates. This idea conflicts with the fact that cardiac looping occurs in all vertebrates, including gill-breathing fishes. We speculate that looping morphogenesis may improve the efficiency of valveless pumping. To test the physical plausibility of this hypothesis, we analyzed the pumping performance of a Liebau-effect pump in straight and looped (kinked configurations. Compared to the straight configuration, the looped configuration significantly improved the pumping performance of our pump. This shows that looping can improve the efficiency of valveless pumping driven by the Liebau-effect. Further studies are needed to clarify whether this finding may have implications for understanding of the form-function relationship of embryonic hearts.

  12. The 2006 Eruption of Raoul Volcano (Kermadecs): A Phreato-magmatic Event From a Hydrothermally-Sealed Volcanic Conduit System.

    Science.gov (United States)

    Christenson, B. W.; Reyes, A. G.; Werner, C. A.

    2006-12-01

    The March 17, 2006 eruption from Raoul volcano (Kermadec Islands, NZ), which tragically claimed the life of NZ Department of Conservation staff member Mark Kearney, is being interpreted as a magmatic-hydrothermal event triggered by shaking associated with regional earthquake swarm activity. Although the eruption released ca. 200 T of SO2, thus confirming its magmatic nature, it occurred without significant precursory volcanic seismicity, and without any of the precursory responses of the volcanic hydrothermal system which were observed prior to the last eruption in 1964. Raoul Island has a long and varied eruption history dating back > 1.4 ma, and has been hydrothermally active throughout historic time. Present day fumarolic and hotspring discharges within Raoul caldera point to the existence of a small but well established, mixed meteoric - seawater hydrothermal system within the volcano. Magmatic signatures are apparent in fumarolic gas discharges, but are heavily masked by their interaction with hydrothermal system fluids (eg. near complete scrubbing of sulphur and halogen gases from the boiling point fumarolic discharges). A diffuse degassing study conducted in 2004 revealed that ca. 80 T/d CO2 is passively discharged from the volcano, suggesting that ongoing (albeit low level) convective degassing of magma occurs at depth. Interestingly, vent locations from the 2006 eruption correspond to areas of relatively low CO2 discharge on the crater floor in 2004. This, in conjunction with the preliminary findings of abundant hydrothermal mineralisation (calcite, anhydrite, quartz) in eruption ejecta, suggests that the main volcanic conduits had become effectively sealed during the interval since the last eruption. Calcite-hosted fluid inclusions are CO2 clathrate-bearing, and have relatively low homogenisation temperatures (165-180 °C), suggesting that the seal environment was both gas-charged and shallowly seated (< 200 m). Shaking associated with the regional

  13. Minimizing coupling loss by selection of twist pitch lengths in multi-stage cable-in-conduit conductors

    International Nuclear Information System (INIS)

    Rolando, G; Nijhuis, A; Devred, A

    2014-01-01

    The numerical code JackPot-ACDC (van Lanen et al 2010 Cryogenics 50 139–48, van Lanen et al 2011 IEEE Trans. Appl. Supercond. 21 1926–9, van Lanen et al 2012 Supercond. Sci. Technol. 25 025012) allows fast parametric studies of the electro-magnetic performance of cable-in-conduit conductors (CICCs). In this paper the code is applied to the analysis of the relation between twist pitch length sequence and coupling loss in multi-stage ITER-type CICCs. The code shows that in the analysed conductors the coupling loss is at its minimum when the twist pitches of the successive cabling stages have a length ratio close to one. It is also predicted that by careful selection of the stage-to-stage twist pitch ratio, CICCs cabled according to long twist schemes in the initial stages can achieve lower coupling loss than conductors with shorter pitches. The result is validated by AC loss measurements performed on prototype conductors for the ITER Central Solenoid featuring different twist pitch sequences. (paper)

  14. Enhanced peripheral nerve regeneration through asymmetrically porous nerve guide conduit with nerve growth factor gradient.

    Science.gov (United States)

    Oh, Se Heang; Kang, Jun Goo; Kim, Tae Ho; Namgung, Uk; Song, Kyu Sang; Jeon, Byeong Hwa; Lee, Jin Ho

    2018-01-01

    In this study, we fabricated a nerve guide conduit (NGC) with nerve growth factor (NGF) gradient along the longitudinal direction by rolling a porous polycaprolactone membrane with NGF concentration gradient. The NGF immobilized on the membrane was continuously released for up to 35 days, and the released amount of the NGF from the membrane gradually increased from the proximal to distal NGF ends, which may allow a neurotrophic factor gradient in the tubular NGC for a sufficient period. From the in vitro cell culture experiment, it was observed that the PC12 cells sense the NGF concentration gradient on the membrane for the cell proliferation and differentiation. From the in vivo animal experiment using a long gap (20 mm) sciatic nerve defect model of rats, the NGC with NGF concentration gradient allowed more rapid nerve regeneration through the NGC than the NGC itself and NGC immobilized with uniformly distributed NGF. The NGC with NGF concentration gradient seems to be a promising strategy for the peripheral nerve regeneration. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 52-64, 2018. © 2017 Wiley Periodicals, Inc.

  15. Time scales of foam stability in shallow conduits: Insights from analogue experiments

    Science.gov (United States)

    Spina, L.; Scheu, B.; Cimarelli, C.; Arciniega-Ceballos, A.; Dingwell, D. B.

    2016-10-01

    Volcanic systems can exhibit periodical trends in degassing activity, characterized by a wide range of time scales. Understanding the dynamics that control such periodic behavior can provide a picture of the processes occurring in the feeding system. Toward this end, we analyzed the periodicity of outgassing in a series of decompression experiments performed on analogue material (argon-saturated silicone oil plus glass beads/fibers) scaled to serve as models of basaltic magma. To define the effects of liquid viscosity and crystal content on the time scale of outgassing, we investigated both: (1) pure liquid systems, at differing viscosities (100 and 1000 Pa s), and (2) particle-bearing suspensions (diluted and semidiluted). The results indicate that under dynamic conditions (e.g., decompressive bubble growth and fluid ascent within the conduit), the periodicity of foam disruption may be up to several orders of magnitude less than estimates based on the analysis of static conditions. This difference in foam disruption time scale is inferred to result from the contribution of bubble shear and bubble growth to inter-bubble film thinning. The presence of particles in the semidiluted regime is further linked to shorter bubble bursting times, likely resulting from contributions of the presence of a solid network and coalescence processes to the relative increase in bubble breakup rates. Finally, it is argued that these experiments represent a good analogue of gas-piston activity (i.e., the periodical rise-and-fall of a basaltic lava lake surface), implying a dominant role for shallow foam accumulation as a source process for these phenomena.

  16. Computational modeling of lava domes using particle dynamics to investigate the effect of conduit flow mechanics on flow patterns

    Science.gov (United States)

    Husain, Taha Murtuza

    Large (1--4 x 106 m3) to major (> 4 x 106 m3) dome collapses for andesitic lava domes such as Soufriere Hills Volcano, Montserrat are observed for elevated magma discharge rates (6--13 m3/s). The gas rich magma pulses lead to pressure build up in the lava dome that result in structural failure of the over steepened canyon-like walls which may lead to rockfall or pyroclastic flow. This indicates that dome collapse intimately related to magma extrusion rate. Variation in magma extrusion rate for open-system magma chambers is observed to follow alternating periods of high and low activity. Periodic behavior of magma exhibits a rich diversity in the nature of its eruptive history due to variation in magma chamber size, total crystal content, linear crystal growth rate and magma replenishment rate. Distinguished patterns of growth were observed at different magma flow rates ranging from endogenous to exogenous dome growth for magma with varying strengths. Determining the key parameters that control the transition in flow pattern of the magma during its lava dome building eruption is the main focus. This dissertation examines the mechanical effects on the morphology of the evolving lava dome on the extrusion of magma from a central vent using a 2D particle dynamics model. The particle dynamics model is coupled with a conduit flow model that incorporates the kinetics of crystallization and rheological stiffening to investigate important mechanisms during lava dome building eruptions. Chapter I of this dissertation explores lava dome growth and failure mechanics using a two-dimensional particle-dynamics model. The model follows the evolution of fractured lava, with solidification driven by degassing induced crystallization of magma. The particle-dynamics model emulates the natural development of dome growth and rearrangement of the lava dome which is difficult in mesh-based analyses due to mesh entanglement effects. The deformable talus evolves naturally as a frictional

  17. Experimental and theoretical fracture mechanics applied to volcanic conduits and domes

    Science.gov (United States)

    Sammonds, P.; Matthews, C.; Kilburn, C.; Smith, R.; Tuffen, H.; Meredith, P.

    2008-12-01

    We present an integrated modelling and experimental approach to magma deformation and fracture, which we attempt to validate against field observations of seismicity. The importance of fracture processes in magma ascent dynamics and lava dome growth and collapse are apparent from the associated seismicity. Our laboratory experiments have shown that brittle fracture of magma can occur at high temperature and stress conditions prevalent in the shallow volcanic system. Here, we use a fracture mechanics approach to model seismicity preceding volcanic eruptions. Starting with the fracture mechanics concept of a crack in an elastic body, we model crack growth around the volcanic conduit through the processes of crack interactions, leading either to the propagation and linkage of cracks, or crack avoidance and the inhibition of crack propagation. The nature of that interaction is governed by the temperature and plasticity of the magma. We find that fracture mechanics rules can account for the style of seismicity preceding eruptions. We have derived the changes in seismic b-value predicted by the model and interpret these in terms of the style of fracturing, fluid flow and heat transport. We compare our model with results from our laboratory experiments where we have deformed lava at high temperatures under triaxial stresses. These experiments were conducted in dry and water saturated conditions at effective pressures up to 10 MPa, temperatures up to 1000°C and strain rates from 10-4 s-1 to 10-6 s-1. The behaviour of these magmas was largely brittle under these conditions. We monitored the acoustic emission emitted and calculate the change in micro-seismic b-value with deformation. These we find are in accord with volcano seismicity and our fracture mechanics model.

  18. Effect of Surface Pore Structure of Nerve Guide Conduit on Peripheral Nerve Regeneration

    Science.gov (United States)

    Oh, Se Heang; Kim, Jin Rae; Kwon, Gu Birm; Namgung, Uk; Song, Kyu Sang

    2013-01-01

    Polycaprolactone (PCL)/Pluronic F127 nerve guide conduits (NGCs) with different surface pore structures (nano-porous inner surface vs. micro-porous inner surface) but similar physical and chemical properties were fabricated by rolling the opposite side of asymmetrically porous PCL/F127 membranes. The effect of the pore structure on peripheral nerve regeneration through the NGCs was investigated using a sciatic nerve defect model of rats. The nerve fibers and tissues were shown to have regenerated along the longitudinal direction through the NGC with a nano-porous inner surface (Nanopore NGC), while they grew toward the porous wall of the NGC with a micro-porous inner surface (Micropore NGC) and, thus, their growth was restricted when compared with the Nanopore NGC, as investigated by immunohistochemical evaluations (by fluorescence microscopy with anti-neurofilament staining and Hoechst staining for growth pattern of nerve fibers), histological evaluations (by light microscopy with Meyer's modified trichrome staining and Toluidine blue staining and transmission electron microscopy for the regeneration of axon and myelin sheath), and FluoroGold retrograde tracing (for reconnection between proximal and distal stumps). The effect of nerve growth factor (NGF) immobilized on the pore surfaces of the NGCs on nerve regeneration was not so significant when compared with NGCs not containing immobilized NGF. The NGC system with different surface pore structures but the same chemical/physical properties seems to be a good tool that is used for elucidating the surface pore effect of NGCs on nerve regeneration. PMID:22871377

  19. The dynamics of slug trains in volcanic conduits: Evidence for expansion driven slug coalescence

    Science.gov (United States)

    Pering, T. D.; McGonigle, A. J. S.; James, M. R.; Capponi, A.; Lane, S. J.; Tamburello, G.; Aiuppa, A.

    2017-12-01

    Strombolian volcanism is a ubiquitous form of activity, driven by the ascent and bursting of bubbles of slug morphology. Whilst considerable attention has been devoted to understanding the behaviour of individual slugs in this regime, relatively little is known about how inter-slug interactions modify flow conditions. Recently, we reported on high temporal frequency strombolian activity on Etna, in which the larger erupted slug masses were followed by longer intervals before the following explosion than the smaller bursts (Pering et al., 2015). We hypothesised that this behaviour arose from the coalescence of ascending slugs causing a prolonged lag before arrival of the next distinct bubble. Here we consider the potential importance of inter-slug interactions for the dynamics of strombolian volcanism, by reporting on the first study into the behaviour of trains of ascending gas slugs, scaled to the expansion rates in volcanic conduits. This laboratory analogue study illustrates that slugs in trains rise faster than individual slugs, and can be associated with aspects of co-current flow. The work also highlights that coalescence and inter-slug interactions play an important role in modulating slug train behaviour. We also report, for the first time, on slug coalescence driven by vertical expansion of the trailing slug, a process which can occur, even where the leading slug base ascent velocity is greater than that of the trailing slug.

  20. Evasion of CO2 from streams - the dominant component of the carbon export through the aquatic conduit in a boreal landscape.

    Science.gov (United States)

    Wallin, Marcus B; Grabs, Thomas; Buffam, Ishi; Laudon, Hjalmar; Agren, Ånneli; Öquist, Mats G; Bishop, Kevin

    2013-03-01

    Evasion of gaseous carbon (C) from streams is often poorly quantified in landscape C budgets. Even though the potential importance of the capillary network of streams as C conduits across the land-water-atmosphere interfaces is sometimes mentioned, low-order streams are often left out of budget estimates due to being poorly characterized in terms of gas exchange and even areal surface coverage. We show that evasion of C is greater than all the total dissolved C (both organic and inorganic) exported downstream in the waters of a boreal landscape. In this study evasion of carbon dioxide (CO2 ) from running waters within a 67 km(2) boreal catchment was studied. During a 4 year period (2006-2009) 13 streams were sampled on 104 different occasions for dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC). From a locally determined model of gas exchange properties, we estimated the daily CO2 evasion with a high-resolution (5 × 5 m) grid-based stream evasion model comprising the entire ~100 km stream network. Despite the low areal coverage of stream surface, the evasion of CO2 from the stream network constituted 53% (5.0 (±1.8) g C m(-2)  yr(-1) ) of the entire stream C flux (9.6 (±2.4) g C m(-2)  yr(-1) ) (lateral as DIC, DOC, and vertical as CO2 ). In addition, 72% of the total CO2 loss took place already in the first- and second-order streams. This study demonstrates the importance of including CO2 evasion from low-order boreal streams into landscape C budgets as it more than doubled the magnitude of the aquatic conduit for C from this landscape. Neglecting this term will consequently result in an overestimation of the terrestrial C sink strength in the boreal landscape. © 2012 Blackwell Publishing Ltd.

  1. Surgical Anatomy and Microvascular Surgical Technique Relevant to Experimental Renal Transplant in Rat Employing Aortic and Inferior Venacaval Conduits.

    Science.gov (United States)

    Shrestha, Badri Man; Haylor, John

    2017-11-15

    Rat models of renal transplant are used to investigate immunologic processes and responses to therapeutic agents before their translation into routine clinical practice. In this study, we have described details of rat surgical anatomy and our experiences with the microvascular surgical technique relevant to renal transplant by employing donor inferior vena cava and aortic conduits. For this study, 175 rats (151 Lewis and 24 Fisher) were used to establish the Fisher-Lewis rat model of chronic allograft injury at our institution. Anatomic and technical details were recorded during the period of training and establishment of the model. A final group of 12 transplanted rats were studied for an average duration of 51 weeks for the Lewis-to-Lewis isografts (5 rats) and 42 weeks for the Fisher-to-Lewis allografts (7 rats). Functional measurements and histology confirmed the diagnosis of chronic allograft injury. Mastering the anatomic details and microvascular surgical techniques can lead to the successful establishment of an experimental renal transplant model.

  2. Electromagnetic analysis of a superconducting transformer for high current characterization of cable in conduit conductors in background magnetic field

    Science.gov (United States)

    Wu, Xiangyang; Tan, Yunfei; Fang, Zhen; Jiang, Donghui; Chen, Zhiyou; Chen, Wenge; Kuang, Guangli

    2017-10-01

    A large cable-in-conduit-conductor (CICC) test facility has been designed and fabricated at the High Magnetic Field Laboratory of the Chinese Academy of Sciences (CHMFL) in order to meet the test requirement of the conductors which are applied to the future fusion reactor. The critical component of the test facility is an 80 kA superconducting transformer which consists of a multi-turn primary coil and a minor-turn secondary coil. As the current source of the conductor samples, the electromagnetic performance of the superconducting transformer determines the stability and safety of the test facility. In this paper, the key factors and parameters, which have much impact on the performance of the transformer, are analyzed in detail. The conceptual design and optimizing principles of the transformer are discussed. An Electromagnetic-Circuit coupled model built in ANSYS Multiphysics is successfully used to investigate the electromagnetic characterization of the transformer under the dynamic operation condition.

  3. Calcite veining and feeding conduits in a hydrothermal system: Insights from a natural section across the Pleistocene Gölemezli travertine depositional system (western Anatolia, Turkey)

    Science.gov (United States)

    Capezzuoli, Enrico; Ruggieri, Giovanni; Rimondi, Valentina; Brogi, Andrea; Liotta, Domenico; Alçiçek, Mehmet Cihat; Alçiçek, Hülya; Bülbül, Ali; Gandin, Anna; Meccheri, Marco; Shen, Chuan-Chou; Baykara, Mehmet Oruç

    2018-02-01

    Linking the architecture of structural conduits with the hydrothermal fluids migrating from the reservoir up to the surface is a key-factor in geothermal research. A contribution to this achievement derives from the study of spring-related travertine deposits, but although travertine depositional systems occur widely, their feeding conduits are only rarely exposed. The integrated study carried out in the geothermal Gölemezli area, nearby the well-known Pamukkale area (Denizli Basin, western Anatolia, Turkey), focused on onyx-like calcite veins (banded travertine) and bedded travertine well exposed in a natural cross-section allowing the reconstruction of the shallower part of a geothermal system. The onyx-like veins represent the thickest vein network (> 150 m) so far known. New field mapping and structural/kinematic analyses allowed to document a partially dismantled travertine complex (bedded travertine) formed by proximal fissure ridges and distal terraced/pools depositional systems. The banded calcite veins, WNW-trending and up to 12 m thick, developed within a > 200 m thick damaged rock volume produced by parallel fault zones. Th/U dating indicates a long lasting (middle-late Pleistocene) fluids circulation in a palaeo-geothermal system that, due to its location and chemical characteristics, can be considered the analogue of the nearby, still active, Pamukkale system. The isotopic characteristics of the calcite veins together with data from fluid inclusions analyses, allow the reconstruction of some properties (i.e. temperature, salinity and isotopic composition) and processes (i.e. temperature variation and intensity of degassing) that characterized the parent fluids and the relation between degassing intensity and specific microfabric of calcite crystals (elongated/microsparite-micrite bands), controlled by changes/fluctuations of the physico-chemical fluid characteristics.

  4. Nanopatterned acellular valve conduits drive the commitment of blood-derived multipotent cells

    Directory of Open Access Journals (Sweden)

    Di Liddo R

    2016-10-01

    Full Text Available Rosa Di Liddo,1,2 Paola Aguiari,3 Silvia Barbon,1,2 Thomas Bertalot,1 Amit Mandoli,1 Alessia Tasso,1 Sandra Schrenk,1 Laura Iop,3 Alessandro Gandaglia,3 Pier Paolo Parnigotto,2 Maria Teresa Conconi,1,2 Gino Gerosa31Department of Pharmaceutical and Pharmacological Sciences, University of Padova, 2Foundation for Biology and Regenerative Medicine, Tissue Engineering and Signaling ONLUS, 3Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy Abstract: Considerable progress has been made in recent years toward elucidating the correlation among nanoscale topography, mechanical properties, and biological behavior of cardiac valve substitutes. Porcine TriCol scaffolds are promising valve tissue engineering matrices with demonstrated self-repopulation potentiality. In order to define an in vitro model for investigating the influence of extracellular matrix signaling on the growth pattern of colonizing blood-derived cells, we cultured circulating multipotent cells (CMC on acellular aortic (AVL and pulmonary (PVL valve conduits prepared with TriCol method and under no-flow condition. Isolated by our group from Vietnamese pigs before heart valve prosthetic implantation, porcine CMC revealed high proliferative abilities, three-lineage differentiative potential, and distinct hematopoietic/endothelial and mesenchymal properties. Their interaction with valve extracellular matrix nanostructures boosted differential messenger RNA expression pattern and morphologic features on AVL compared to PVL, while promoting on both matrices the commitment to valvular and endothelial cell-like phenotypes. Based on their origin from peripheral blood, porcine CMC are hypothesized in vivo to exert a pivotal role to homeostatically replenish valve cells and contribute to hetero- or allograft colonization. Furthermore, due to their high responsivity to extracellular matrix nanostructure signaling, porcine CMC could be useful for a preliminary

  5. The effects of fenoldopam on coronary conduit blood flow after coronary artery bypass graft surgery.

    LENUS (Irish Health Repository)

    Halpenny, M

    2012-02-03

    OBJECTIVE: To quantify the effects of fenoldopam, 0.1 microg\\/kg\\/min, on left internal mammary artery (LIMA) and saphenous vein blood flow after coronary anastomosis. DESIGN: Prospective, randomized, double-blind, placebo-controlled trial. SETTING: University teaching hospital, single institution. PARTICIPANTS: Thirty-one American Society of Anesthesiologists III patients undergoing elective coronary revascularization. INTERVENTIONS: A perivascular ultrasonic flow probe (Linton Instrumentation, Norfolk, UK) was placed around the LIMA and saphenous vein graft after coronary anastomosis. MEASUREMENTS AND MAIN RESULTS: Immediately before and at 5-minute intervals for 15 minutes after starting the infusion, blood flow was measured in the LIMA and one saphenous vein graft using a transit time ultrasonic flow probe. Heart rate, blood pressure, and central venous pressure were documented at these time points. Administration of fenoldopam, 0.1 microg\\/kg\\/min, did not alter heart rate or blood pressure. A small, nonsignificant increase in LIMA blood flow occurred during the 15-minute study period (30 +\\/- 12 to 35 +\\/- 10 mL\\/min) in patients who received fenoldopam. No significant changes occurred in the placebo group. CONCLUSIONS: The findings indicate that fenoldopam, 0.1 microg\\/kg\\/min, did not influence coronary conduit blood flow to a clinically significant extent. The small increase in LIMA blood flow may be of greater importance in high-risk patients or in the prevention of coronary arterial spasm.

  6. Operação de Rastelli utilizando-se conduto valvulado de pericárdio bovino: experiência inicial Rastelli operation with bovine pericardium valved conduit: early experience

    Directory of Open Access Journals (Sweden)

    Carlos R Moraes

    1988-08-01

    of the great arteries, VSD and subpulmonic stenosis, one had pulmonary atresia, VSD and a previous Waterston shunt, and one had a type II truncus arteriosus. Two patients died of causes unrelated to the type of the conduit used. The valved conduit of preserved bovine pericardium is easy to handle due to its excellent flexibility, allowing perfect adaptability inside the pericardial sac. The absence of a supporting ring abolish gradient across the conduit and turbulence which are recognized causes of calcification.

  7. Shallow conduit processes of the 1991 Hekla eruption, Iceland

    Science.gov (United States)

    Gudnason, J.; Thordarson, T.; Houghton, B. F.

    2013-12-01

    On January 17, 1991 at 17:00 hrs, the 17th eruption of Hekla since 1104AD began. Lasting for almost two months, it produced 0.02 km3 of icelandite tephra and ~0.15km3 of icelandite lava. This eruption was the third of four eruptions since 1980 with a recurrence period of approximately 10 years, as opposed to a recurrence interval of c. 55 years for the eruptions in the period 1104AD to 1947AD. [1] The last four Hekla eruptions are typified by a 0.5-2 hour-long initial phase of subplinian intensity and discharge ranging from 2900-6700 m3/s [2]. In all 4 events the inital phase was followed by a sustained and relatively low-discharge(sorted tephra fall covering >20,000 km2. Here we examine the first phase of the Hekla 1991 eruption with focus on vesiculation and fragmentation processes in the shallow conduit and ash production. Samples of the tephra fall were collected on snow immediately after the initial phase at multiple sites providing a representative spatial coverage within the 0.1mm isopach [3]. This set was augmented by samples collected in 2012 to provide tighter coverage of near vent region. Grain size of all samples has been measured down to 1 micron. Density measurements have been conducted on 4 near-vent pumice samples (100 clasts each) and the pumice vesicle size distribution has been determined in a selected subset of clasts. The reconstructed whole deposit grain size distribution exhibits a unimodal, log-normal distribution peaking at -3 phi, typical of dry, magmatic fragmentation. Pumice densities range from 520-880 kg/m3 and exhibit a tight unimodal and log-normal distribution indicating a mean vesicularity of 77% to 79% for the magma erupted during the initial phase. Along with preliminary results for bubble number density and vesicle size distribution this implies a single late-stage homogeneous bubble nucleation and very uniform conditions of magma fragmentation during this short-lived initial phase of the Hekla 1991 eruption. 1. Gudmundsson, A

  8. Effect of current imbalance on stability of a cable-in-conduit conductor consisting of chrome-plated strands

    International Nuclear Information System (INIS)

    Koizumi, Norikiyo; Takahashi, Yoshikazu; Nishi, Masataka; Isono, Takaaki; Tsuji, Hiroshi; Ono, Michitaka; Hamajima, Takataro; Fujioka, Tsutomu.

    1997-02-01

    The effect of an unbalanced current distribution in a conductor consisting of chrome plated strands on stability was investigated using a cable-in-conduit conductor (CICC) consisting of 27 NbTi chrome-plated strands. In addition, the quench behavior when a non-uniform current distribution was produced in the conductor was studied from the experimental results. Moreover, impedance of the chrome-plated strands was measured using the sample conductor. The results show that the stability is determined by the largest strand current when it is sufficiently large otherwise by the transport current when it is not high enough. It was found that it took a long time to make the conductor quench from the onset of the normal transition of the strand carrying the large current. This is explained by the good diffusivity of the coolant temperature in the conductor's cross section. Since the ramp-rate limitation cannot probably take place if the coolant temperature is diffused well in the conductor's cross section, it is expected the ramp-rate limitation can be prevented using this effect. It is also shown that the chrome-plated strands come into contact with one another with uniform transverse conductance on the order of 10 3 S/m. (author)

  9. submitter Design and Manufacturing of a 45 kA at 10 T REBCO-CORC Cable-in-Conduit Conductor for Large-Scale Magnets

    CERN Document Server

    Mulder, Tim; Mentink, Matthias; Silva, Helder; van der Laan, Danko; Dhalle, Marc; ten Kate, Herman

    2016-01-01

    The European Organization for Nuclear Research (CERN) is developing high-current ReBCO-CORC strand-based cables for use in future large-scale detector magnets. A six-around-one, forced flow gas-cooled ReBCO-CORC cable-in-conduit conductor (CICC) is envisioned for application in magnets operating in the 20-40 K temperature range. A CICC, rated for 45 kA at 4.2 K and 10 T, is designed and in production. The CICC comprises a cable of six CORC strands helically wound around a tube. The cable has an expected current density of 105 $A/mm^2$ at 10 T/4.2 K, which corresponds to an overall current density of 53 $A/mm^2$. A cable current density of 110 $A/mm^2$ can be reached when increasing the temperature to 20 K and operating in a magnetic field of 5 T.

  10. The Medial Temporal Lobe – Conduit of Parallel Connectivity: A model for Attention, Memory, and Perception.

    Directory of Open Access Journals (Sweden)

    Brian B. Mozaffari

    2014-11-01

    Full Text Available Based on the notion that the brain is equipped with a hierarchical organization, which embodies environmental contingencies across many time scales, this paper suggests that the medial temporal lobe (MTL – located deep in the hierarchy – serves as a bridge connecting supra to infra – MTL levels. Bridging the upper and lower regions of the hierarchy provides a parallel architecture that optimizes information flow between upper and lower regions to aid attention, encoding, and processing of quick complex visual phenomenon. Bypassing intermediate hierarchy levels, information conveyed through the MTL ‘bridge’ allows upper levels to make educated predictions about the prevailing context and accordingly select lower representations to increase the efficiency of predictive coding throughout the hierarchy. This selection or activation/deactivation is associated with endogenous attention. In the event that these ‘bridge’ predictions are inaccurate, this architecture enables the rapid encoding of novel contingencies. A review of hierarchical models in relation to memory is provided along with a new theory, Medial-temporal-lobe Conduit for Parallel Connectivity (MCPC. In this scheme, consolidation is considered as a secondary process, occurring after a MTL-bridged connection, which eventually allows upper and lower levels to access each other directly. With repeated reactivations, as contingencies become consolidated, less MTL activity is predicted. Finally, MTL bridging may aid processing transient but structured perceptual events, by allowing communication between upper and lower levels without calling on intermediate levels of representation.

  11. Assessment of a magnet system combining the advantages of cable-in-conduit forced-flow and pool-boiling magnets

    International Nuclear Information System (INIS)

    Slack, D.; Hassenzahl, W.; Felker, B.; Chaplin, M.

    1993-01-01

    This paper presents an idea for a magnet system that could be used to advantage in tokamaks and other fusion engineering devices. Higher performance designs, specifically newer tokamaks such as those for the international Tokamak Engineering Reactor (ITER) and Tokamak Physics Experiment (TPX) use Cable in Conduit Conductor (CICC) forced flow coils to advantage to meet field and current density requirements. Pool boiling magnets lack structural integrity to resist high magnetic forces since helium cooling areas must surround each conductor. A second problem is that any leak can threaten the voltage standoff integrity of the magnet system. This is because a leak can result in low-pressure helium gas becoming trapped by limited conductance in the magnet bundle and low-pressure helium has poor dielectric strength. The system proposed here is basically a CICC system, with it's inherent advantages, but bathed in higher pressure supercritical helium to eliminate the leak and voltage break-down problems. Schemes to simplify helium coolant plumbing with the proposed system are discussed. A brief historical review of related magnet systems is included. The advantages and disadvantages of using higher pressure, supercritical helium in combination with solid electrical insulation in a CICC system are discussed. Related electrical data from some previous works are compiled and discussed

  12. Speleogenesis, geometry, and topology of caves: A quantitative study of 3D karst conduits

    Science.gov (United States)

    Jouves, Johan; Viseur, Sophie; Arfib, Bruno; Baudement, Cécile; Camus, Hubert; Collon, Pauline; Guglielmi, Yves

    2017-12-01

    Karst systems are hierarchically spatially organized three-dimensional (3D) networks of conduits behaving as drains for groundwater flow. Recently, geostatistical approaches proposed to generate karst networks from data and parameters stemming from analogous observed karst features. Other studies have qualitatively highlighted relationships between speleogenetic processes and cave patterns. However, few studies have been performed to quantitatively define these relationships. This paper reports a quantitative study of cave geometries and topologies that takes the underlying speleogenetic processes into account. In order to study the spatial organization of caves, a 3D numerical database was built from 26 caves, corresponding to 621 km of cumulative cave passages representative of the variety of karst network patterns. The database includes 3D speleological surveys for which the speleogenetic context is known, allowing the polygenic karst networks to be divided into 48 monogenic cave samples and classified into four cave patterns: vadose branchwork (VB), water-table cave (WTC), looping cave (LC), and angular maze (AM). Eight morphometric cave descriptors were calculated, four geometrical parameters (width-height ratio, tortuosity, curvature, and vertical index) and four topological ones (degree of node connectivity, α and γ graph indices, and ramification index) respectively. The results were validated by statistical analyses (Kruskal-Wallis test and PCA). The VB patterns are clearly distinct from AM ones and from a third group including WTC and LC. A quantitative database of cave morphology characteristics is provided, depending on their speleogenetic processes. These characteristics can be used to constrain and/or validate 3D geostatistical simulations. This study shows how important it is to relate the geometry and connectivity of cave networks to recharge and flow processes. Conversely, the approach developed here provides proxies to estimate the evolution of

  13. Aortic root surgery in Marfan syndrome: Bentall procedure with the composite mechanical valved conduit versus aortic valve reimplantation with Valsalva graft.

    Science.gov (United States)

    Nardi, Paolo; Pellegrino, Antonio; Versaci, Francesco; Mantione, Ludmilla; Polisca, Patrizio; Iorio, Fiore S; Chiariello, Luigi

    2010-09-01

    The aim of the study is to compare mid-term results of Bentall aortic root replacement with composite mechanical valved conduit and aortic valve reimplantation procedure using the Valsalva graft for the treatment of aortic root aneurysm in patients with Marfan syndrome. We retrospectively compared data of 23 patients (mean age 38 + or - 14 years) who had undergone the Bentall procedure (group B) to those of 24 patients (mean age 36 + or - 12 years) who had undergone aortic valve reimplantation (group R) during a 14-year period. Follow-up (mean duration 65 + or - 44 months) was 100% complete. There were no operative deaths in either group. In group B, as compared with group R, preoperative aortic insufficiency (3.2 + or - 1.1/4 vs. 1.7 + or - 1.4/4, P Marfan patients, the Bentall procedure is associated with excellent mid-term outcome. The reimplantation technique, adopted for less dilated aortas, provides similarly satisfactory results. The Valsalva graft seems, with time, to allow a stable aortic valve function.

  14. Magmas in motion: Degassing in volcanic conduits and fabrics of pyroclastic density current

    Science.gov (United States)

    Burgisser, Alain

    Volcanoes are caused by the transport of magma batches from the Earth's crust to the surface. These magmas in motion undergo drastic changes of rheologic properties during their journey to the surface and this work explores how these changes affect volcanic eruptions. The first part of this study is devoted to the dynamic aspects of degassing and permeability in magmas with high pressure, high temperature experiments on natural volcanic rocks. Degassing is measured by the influence of decompression rate on the growth of the bubbles present in the magma while permeability is deduced from the temporal evolution of these bubbles. The parameterization of our results in a numerical model of volcanic conduit flow show that previous models based on equilibrium degassing overestimate the acceleration and the decompression rate of the magma. Assessing permeability effects derived form our results show that the transition between explosive and effusive eruptions is a strong function of the magma initial ascent rate. The second part of this work is a unification of two end-members of pyroclastic currents (highly concentrated pyroclastic flows and dilute, turbulent pyroclastic surges) using theoretical scaling arguments based on multiphase physics. Starting from the dynamics of the particle interactions with a fundamental eddy, we consider the full spectrum of eddies generated within a turbulent current. We demonstrate that the presence of particles with various sizes induces a density stratification of the current, leading to its segregation into a basal concentrated part overlain by a dilute cloud. To verify our predictions on the interactions of such a segregated pyroclastic current with its surroundings (hills and sea), we studied the products of the 2050 BP caldera-forming eruption of Okmok Volcano (Alaska). This field study allowed us to reconstruct the eruptive sequence and to validate the main aspects of our theoretical model, such as the superposition of a dense and

  15. Fibulin-4 is essential for maintaining arterial wall integrity in conduit but not muscular arteries.

    Science.gov (United States)

    Halabi, Carmen M; Broekelmann, Thomas J; Lin, Michelle; Lee, Vivian S; Chu, Mon-Li; Mecham, Robert P

    2017-05-01

    Homozygous or compound heterozygous mutations in fibulin-4 ( FBLN4 ) lead to autosomal recessive cutis laxa type 1B (ARCL1B), a multisystem disorder characterized by significant cardiovascular abnormalities, including abnormal elastin assembly, arterial tortuosity, and aortic aneurysms. We sought to determine the consequences of a human disease-causing mutation in FBLN4 (E57K) on the cardiovascular system and vascular elastic fibers in a mouse model of ARCL1B. Fbln4 E57K/E57K mice were hypertensive and developed arterial elongation, tortuosity, and ascending aortic aneurysms. Smooth muscle cell organization within the arterial wall of large conducting vessels was abnormal, and elastic fibers were fragmented and had a moth-eaten appearance. In contrast, vessel wall structure and elastic fiber integrity were normal in resistance/muscular arteries (renal, mesenteric, and saphenous). Elastin cross-linking and total elastin content were unchanged in large or small arteries, whereas elastic fiber architecture was abnormal in large vessels. While the E57K mutation did not affect Fbln4 mRNA levels, FBLN4 protein was lower in the ascending aorta of mutant animals compared to wild-type arteries but equivalent in mesenteric arteries. We found a differential role of FBLN4 in elastic fiber assembly, where it functions mainly in large conduit arteries. These results suggest that elastin assembly has different requirements depending on vessel type. Normal levels of elastin cross-links in mutant tissue call into question FBLN4's suggested role in mediating lysyl oxidase-elastin interactions. Future studies investigating tissue-specific elastic fiber assembly may lead to novel therapeutic interventions for ARCL1B and other disorders of elastic fiber assembly.

  16. Spatial resolution of transport parameters in a subtropical karst conduit system during dry and wet seasons

    Science.gov (United States)

    Ender, Anna; Goeppert, Nadine; Goldscheider, Nico

    2018-04-01

    Karst aquifers are characterized by a high degree of hydrologic variability and spatial heterogeneity of transport parameters. Tracer tests allow the quantification of these parameters, but conventional point-to-point experiments fail to capture spatiotemporal variations of flow and transport. The goal of this study was to elucidate the spatial distribution of transport parameters in a karst conduit system at different flow conditions. Therefore, six tracer tests were conducted in an active and accessible cave system in Vietnam during dry and wet seasons. Injections and monitoring were done at five sites along the flow system: a swallow hole, two sites inside the cave, and two springs draining the system. Breakthrough curves (BTCs) were modeled with CXTFIT software using the one-dimensional advection-dispersion model and the two-region nonequilibrium model. In order to obtain transport parameters in the individual sections of the system, a multi-pulse injection approach was used, which was realized by using the BTCs from one section as input functions for the next section. Major findings include: (1) In the entire system, mean flow velocities increase from 183 to 1,043 m/h with increasing discharge, while (2) the proportion of immobile fluid regions decrease; (3) the lowest dispersivity was found at intermediate discharge; (4) in the individual cave sections, flow velocities decrease along the flow direction, related to decreasing gradients, while (5) dispersivity is highest in the middle section of the cave. The obtained results provide a valuable basis for the development of an adapted water management strategy for a projected water-supply system.

  17. Performance of cable-in-conduit conductors in ITER [International Thermonuclear Experimental Reactor] toroidal field coils with varying heat loads

    International Nuclear Information System (INIS)

    Kerns, J.A.; Wong, R.L.

    1989-01-01

    The toroidal field (TF) coils in the International Thermonuclear Experimental Reactor (ITER) will operate with varying heat loads generated by ac losses and nuclear heating. The total heat load is estimated to be 2 kW per TF coil under normal operation and can be higher for different operating scenarios. Ac losses are caused by ramping the poloidal field (PF) for plasma initiation, burn, and shutdown; nuclear heating results from neutrons that penetrate into the coil past the shield. Present methods to reduce or eliminate these losses lead to larger and more expensive machines, which are unacceptable with today's budget constraints. A suitable solution is to design superconductors that operate with high heat loads. The cable-in-conduit conductor (CICC) can operate with high heat loads. One CICC design is analyzed for its thermal performance using two computer codes developed at LLNL. One code calculates the steady state flow conditions along the flow path, while the other calculates the transient conditions in the flow. We have used these codes to analyze the superconductor performance during the burn phase of the ITER plasma. The results of these analyses give insight to the choice of flow rate on superconductor performance. 4 refs., 5 figs

  18. Comparaison des conduites discursives de mères et d’enseignants dans la co-construction de récits avec des enfants

    Directory of Open Access Journals (Sweden)

    Vinel Elise

    2014-07-01

    Full Text Available Cette communication s’intéresse aux conduites discursives produites par des mères et des enseignants au cours de deux lectures conjointes d’album avec des enfants. Elle s’inscrit dans une approche dialogique et interactionniste du langage. Dans la suite des travaux de Florin (1991, Grossmann (1996, analysant les styles d’interaction des enseignants et de réception des enfants en cours de lecture, mais aussi de ceux de Vygotski (1984, Bruner (1994 ou encore Salazar Orvig et De Weck (2014, nous cherchons à comprendre de quelles manières les adultes racontent des histoires aux enfants et à quelles expériences spécifiques des récits ceux-ci sont confrontés. Dix enfants âgés de 3 à 5 ans ont été filmés au cours de ces séances de lectures d’albums, sans texte et avec texte, avec un de leur parent à leur domicile et avec des pairs et des enseignants à l’école.

  19. Quantitative Analysis of Karst Conduit Structure Parameters and Hydraulic Parameters Based on Tracer Test

    Science.gov (United States)

    Qiang, Z.; Zhiqiang, Z.; Xu, M.; Jinyu, S.; Jihong, Q.

    2017-12-01

    The Old Town of Lijiang is famous as the world cultural heritage since 1997, while characterized by its ancient buildings and natural scenery, water is the soul of the town. Around Heilongtan Springs, there are a large quantity of springs at the Old Town of Lijiang , which is an important part of the World Cultural Heritage. Heilongtan Springs is 2420m above the sea level, the annual variation of the flow rate varies greatly (0 8042 x 104 m3 / year). Recharge area Jiuzihai depressions is 6km long, 3km wide and 2800m above sea level, as main karst water recharge area karst funnel and the sink hole are developing on this planation surface, in the research area medium to thick layers of limestone made up Beiya formation (T2b) of Triassic system distributed widely, karst is strongly developed and the fissure caves water occurrence. In order to exploring the application of tracer test in karst hydrogeology, a tracer test was conducted from Jiuzihai depressions to Ganze Spring. Based on the hydrogeological conditions in the study area, tracer test was used for analysis of groundwater connectivity and flow field characteristics, quantitative analysis of Tracer Breakthrough Curves (BTC) with code Qtracer2. The results demonstated that there are hydraulic connection between Jiuzihai depressions with Ganze Spring, and there are other karst conduits in this area. The longitudinal dispersivity coefficient is 0.24 m2/s, longitudinal dispersivity is 12.06m, flow-channel volume is 3.08×104 m3, flow-channel surface area is 3.27×107m2, mean diameter is 1.42m, Reynolds number is 25187, Froude number is 0.0061, respectively. The groundwater in this area is in a slow turbulent state. The results are of great significance to understand the law of groundwater migration, establish groundwater quality prediction model and exploit karst water resources effectively.

  20. The role of external drains and peritoneal conduits in the treatment of recurrent chronic subdural hematoma.

    Science.gov (United States)

    Santarius, Thomas; Qureshi, Hammad U; Sivakumaran, Ram; Kirkpatrick, Peter J; Kirollos, Ramez W; Hutchinson, Peter J

    2010-06-01

    A considerable body of evidence supporting the use of external drainage after evacuation of primary chronic subdural hematoma (CSDH) exists in the literature. However, no systematic study of the value of postoperative drainage in the treatment of recurrent CSDH has been published. The aim of the study was to investigate external drains and subdural-to-peritoneal conduit in the treatment of recurrent CSDH. A retrospective review of cases of CSDH treated in our institution between October 2002 and October 2006 was conducted. During the study period, 408 patients had burr hole evacuation. Sixty-four patients (15.9%) had treatment for recurrence. One patient had craniotomy, and the remaining 63 had another burr hole evacuation: 36 without placement of a drain (BHO), 14 with external drainage (SED), and 13 with placement of subdural-peritoneal catheter (SPC). Fifteen patients (24%) developed a secondary recurrence requiring a third drainage procedure. Postoperative drainage (SED or SPC) was associated with a significantly lower secondary recurrence rate when compared to BHO: 3/27 (11%) versus 12/36 (33%) (χ(2), P=.040). There was no significant difference in recurrence rates between SED and SPC. Postoperative complications included acute subdural hematoma (2), subdural empyema (2), brain edema (2), pneumonia (3), and in-hospital death (2). None of the complications was associated with the use of a specific technique. The results indicate that, as in the treatment of primary CSDHs, the use of drain (SED or SPC) with burr hole evacuation is safe and is associated with lower recurrence rate. Further investigation is needed to clarify the indications of currently available surgical techniques in the treatment of recurrent CSDH. Copyright © 2010 Elsevier Inc. All rights reserved.

  1. Formation of obsidian pyroclasts by sintering of ash particles in the volcanic conduit

    Science.gov (United States)

    Gardner, James E.; Llewellin, Edward W.; Watkins, James M.; Befus, Kenneth S.

    2017-02-01

    The ranges in intensity and style of volcanic eruptions, from highly explosive Plinian eruptions to quiescent lava extrusions, depend on the style and efficiency of gas loss from ascending magma. Obsidian pyroclasts - small, glassy pieces of quenched magma found in some volcanic tephra beds - may preserve valuable information about magma degassing in their vesicle textures and volatile contents. Accurate interpretation of their textures and volatiles, however, requires understanding the mechanism of formation of the pyroclasts. Obsidian pyroclasts from the ca. 1325-1350 C.E. North Mono eruption of Mono Craters (CA, USA) were analyzed and found to have H2O and CO2 contents indicating that they were formed at pressures in the approximate range of 3-40 MPa. Many also contain domains with differing vesicle textures, separated by boundaries containing xenocrystic material, indicating that they are composed of smaller fragments that have sutured together. More than half of the pyroclasts analyzed contained small (∼10 μm), highly distorted vesicles, with multi-cuspate morphology, interpreted as the remnants of interstitial gas trapped amongst sintered fragments of melt/glass. Rounded vesicles are also common and are interpreted to result from surface tension-driven relaxation of the distorted vesicles. Calculated timescales of sintering and relaxation are consistent with timescales for pyroclast formation indicated by H2O re-equilibration within the heterogeneous pyroclasts. This sintering model for the origin of obsidian pyroclasts is further supported by the observation that spherical vesicles are found mainly in H2O-rich pyroclasts, and distorted vesicles mainly in H2O-poor pyroclasts. We conclude that obsidian pyroclasts generated during the North Mono eruption were formed by cycles of fragmentation, sintering/suturing, and relaxation, over a very wide range of depths within the conduit; we find no evidence to support pumice (foam) collapse as the formation

  2. Perioperative management of a patient with Dandy Walker malformation with tetralogy of Fallot undergoing total correction and fresh homologous pericardial pulmonary valve conduit implantation: Report of a rare case

    Directory of Open Access Journals (Sweden)

    Vishnu Datt

    2015-01-01

    Full Text Available Perioperative management of a patient with Dandy-Walker malformation (DWM with tetralogy of Fallot (TOF, patent ductus arteriosus, and pulmonary artery stenosis is a great challenge to the anesthesiologist. Anesthetic management in such patients can trigger tet spells that might rapidly increase intracranial pressure (ICP, conning and even death. The increase in ICP can precipitate tet spells and further brain hypoxia. To avoid an increase in ICP during TOF corrective surgery ventriculo-peritoneal (VP shunt should be performed before cardiac surgery. We present the first case report of a 11-month-old male baby afflicted with DWM and TOF who underwent successful TOF total corrective surgery and fresh autologous pericardial pulmonary valve conduit implantation under cardiopulmonary bypass after 1 week of VP shunt insertion.

  3. Reimplantation valve-sparing aortic root replacement in Marfan syndrome using the Valsalva conduit: an intercontinental multicenter study.

    Science.gov (United States)

    Settepani, Fabrizio; Szeto, Wilson Y; Pacini, Davide; De Paulis, Ruggero; Chiariello, Luigi; Di Bartolomeo, Roberto; Gallotti, Roberto; Bavaria, Joseph E

    2007-02-01

    Introduced by DePaulis in 2000, the Gelweave Valsalva graft (Sulzer Vascutek, Refrewshire, Scotland) is a modified Dacron conduit (DuPont, Wilmington, DE), with prefashioned sinuses of Valsalva. The aim of this study was to evaluate the mid-term results of the reimplantation valve-sparing aortic root replacement using the Gelweave Valsalva prosthesis in Marfan syndrome patients. A retrospective review was performed of 35 patients with Marfan syndrome in four centers who underwent the reimplantation valve-sparing aortic root replacement using the Gelweave Valsalva prosthesis. The patients were predominantly men, with a mean age of 36.5 +/- 12.6 years (range, 14 to 62 years). Two patients presented with acute type A dissections and underwent emergent operations. Elective hemiarch reconstruction using hypothermic circulatory arrest was required in 11 patients. Aortic valve cusp repair was performed in 2 patients. There were no operative or hospital deaths, and no patients died during follow-up. The mean follow-up was 19 months (range, 1 to 60 months). Significant (>2+) aortic insufficiency (AI), requiring aortic valve replacement, developed in 3 patients during follow-up that requiring aortic valve replacement. The 5-year freedom from reoperation owing to structural valve deterioration was 88.9% +/- 8.1%. There were no episodes of clinically significant thromboembolism. Reimplantation valve-sparing aortic root replacement with the Gelweave Valsalva prosthesis in Marfan patients provides satisfactory mid-term results, thus encouraging further use of this type of repair. However, long-term results are needed in order to define the durability of this technique.

  4. Multi-ported, internally recuperated burners for direct flame impingement heating applications

    Energy Technology Data Exchange (ETDEWEB)

    Abbasi, Hamid A. (Naperville, IL); Kurek, Harry (Dyer, IN); Chudnovsky, Yaroslav (Skokie, IL); Lisienko, Vladimir G. (Ekaterinburg, RU); Malikov, German K. (Ekaterinburg, RU)

    2010-08-03

    A direct flame impingement method and apparatus employing at least one multi-ported, internally recuperated burner. The burner includes an innermost coaxial conduit having a first fluid inlet end and a first fluid outlet end, an outermost coaxial conduit disposed around the innermost coaxial conduit and having a combustion products outlet end proximate the first fluid inlet end of the innermost coaxial conduit and a combustion products inlet end proximate the first fluid outlet end of the innermost coaxial conduit, and a coaxial intermediate conduit disposed between the innermost coaxial conduit and the outermost coaxial conduit, whereby a second fluid annular region is formed between the innermost coaxial conduit and the intermediate coaxial conduit and a combustion products annular region is formed between the intermediate coaxial conduit and the outermost coaxial conduit. The intermediate coaxial conduit has a second fluid inlet end proximate the first fluid inlet end of the innermost coaxial conduit and a second fluid outlet end proximate the combustion products inlet end of the outermost coaxial conduit.

  5. Successful performances of the EU-AltTF sample, a large size Nb{sub 3}Sn cable-in-conduit conductor with rectangular geometry

    Energy Technology Data Exchange (ETDEWEB)

    Della Corte, A; Corato, V; Di Zenobio, A; Fiamozzi Zignani, C; Muzzi, L; Polli, G M; Reccia, L; Turtu, S [Associazione EURATOM-ENEA sulla Fusione, Via E Fermi 45, 00044 Frascati, Rome (Italy); Bruzzone, P [EPFL-CRPP, Fusion Technology, 5232 Villigen PSI (Switzerland); Salpietro, E [European Fusion Development Agreement, Close Support Unit, Boltzmannstrasse 2, 85748 Garching (Germany); Vostner, A, E-mail: antonio.dellacorte@enea.i [Fusion for Energy, c/ Josep Pla 2, Edificio B3, 08019 Barcelona (Spain)

    2010-04-15

    One of the design features which yet offers interesting margins for performance optimization of cable-in-conduit conductors (CICCs), is their geometry. For relatively small size Nb{sub 3}Sn CICCs, operating at high electromagnetic pressure, such as those for the EDIPO project, it has been experimentally shown that a design based on a rectangular layout with higher aspect ratio leads to the best performance, especially in terms of degradation with electromagnetic loads. To extend this analysis to larger size Nb{sub 3}Sn CICCs, we manufactured and tested, in the SULTAN facility, an ITER toroidal field (TF) cable, inserted into a thick stainless steel tube and then compacted to a high aspect ratio rectangular shape. Besides establishing a new record in Nb{sub 3}Sn CICC performances for ITER TF type cables, the very good test results confirmed that the conductor properties improve not only by lowering the void fraction and raising the cable twist pitch, as already shown during the ITER TFPRO and the EDIPO test campaigns, but also by the proper optimization of the conductor shape with respect to the electromagnetic force distribution. The sample manufacturing steps, along with the main test results, are presented here.

  6. Magma dynamics within a basaltic conduit revealed by textural and compositional features of erupted ash: the December 2015 Mt. Etna paroxysms.

    Science.gov (United States)

    Pompilio, Massimo; Bertagnini, Antonella; Del Carlo, Paola; Di Roberto, Alessio

    2017-07-06

    In December 2015, four violent explosive episodes from Mt. Etna's oldest summit crater, the Voragine, produced eruptive columns extending up to 15 km a.s.l. and significant fallout of tephra up to a hundred km from the vent. A combined textural and compositional study was carried out on pyroclasts from three of the four tephra deposits sampled on the volcano at 6 to 14 km from the crater. Ash fractions (Φ = 1-2) were investigated because these grain sizes preserve the magma properties unmodified by post- emplacement processes. Results were used to identify processes occurring in the conduit during each single paroxysm and to understand how they evolve throughout the eruptive period. Results indicate that the magmatic column is strongly heterogeneous, mainly with respect to microlite, vescicle content and melt composition. During each episode, the heterogeneities can develop at time scales as short as a few tens of hours, and differences between distinct episodes indicate that the time scale for completely refilling the system and renewing magma is in the same order of magnitude. Our data also confirm that the number and shape of microlites, together with melt composition, have a strong control on rheological properties and fragmentation style.

  7. Dependence of the ac loss on the aspect ratio in a cable in conduit conductor

    International Nuclear Information System (INIS)

    Cau, F; Bruzzone, P

    2010-01-01

    The coupling current loss in rectangular superconducting cables is strictly dependent on their aspect ratio, which has an impact on the area linked by the field variation and consequently on the currents induced between strands. The relation between the ac loss and aspect ratio is studied with reference to the testing of three short cable in conduit conductor (CICC) samples at the SULTAN test facility. The first conductor is a 25 kA NbTi cable for the JT60-SA tokamak; the second is a 20 kA Nb 3 Sn cable for the HZB hybrid magnet. The last CICC is a 68 kA Nb 3 Sn cable with layout similar to that of the ITER toroidal field (TF) conductor (called the 'European toroidal field (EUTF) alternate'). All the samples are assembled with two conductor sections differing only in their orientation with respect to the external variable field. In the first and third samples, the cable of one leg is rotated by 90 0 , while in the HZB sample it is rotated by 45 0 with respect to the other leg. The ac loss is measured at the SULTAN test facility using a gas flow calorimetric method. A sample length of 39 cm is exposed to a sinusoidal field with an amplitude of ± 0.3 or ± 0.2 T (depending on the superconductor) and frequency variable in the range 0.1-0.8 Hz. A background field of 2 T perpendicular both to the sinusoidal field and to the sample axis is also applied. The ac loss is assessed by measuring the variation of the He enthalpy, assuming the metal enthalpy to be negligible. The loss curve for both legs is discussed in terms of the respective aspect ratios and the results, including data from former test campaigns, are compared with the aim of finding an analytical relation between the loss and the conductor dimensions.

  8. Chemistry, mineralogy and alteration intensity of hydrothermal altered Mt Unzen conduit rocks (Shimabara/Japan)

    Science.gov (United States)

    Hess, Kai-Uwe; Yilmaz, Tim; Gilg, H. Albert; Janots, Emilie; Mayer, Klaus; Nakada, Setsuya; Dingwell, Donald

    2017-04-01

    Investigations were carried out on hydrothermally altered coherent dacitic dykes samples from (USDP-4) drill core at Mt Unzen stratovolcano (Shimabara/Japan). XRF, XRD, EMPA, C-O-isotope, hot-cathode CL and SEM analysis led to insights concerning chemistry, mineralogy, and intensity and type of alteration as well as the origin of carbonate-precipitating fluids. Additionally a textural characterization of the occurring replacement features in the volcanic conduit rocks was performed. The occurrence of the main secondary phases such as chlorite, pyrite, carbonates, and R1 (Reichweite parameter) illite-smectite and kaolinite group minerals indicate a weak to moderate propylitic to phyllic hydrothermal alteration. The dacitic samples of the dykes show different hydrothermal alteration features: (i) carbonate and chlorite pseudomorphs after hornblende as well as core and zonal textures due to replacement of plagioclase by R1 illite-smectite as well as kaolinite group minerals, (ii) colloform banded fracture fillings and fillings in dissolution vugs, and (iii) chlorite, R1 illite-smectite as well as kaolinite group minerals in the groundmass. Late chlorite veins crosscut precipitates of R1 illite-smectite as well as kaolinite group minerals. Carbonates in fractures and in pseudomorphs after hornblende comprise iron-rich dolomite solid solutions ("ankerite") and calcite. Isotopic values indicate a hydrothermal-magmatic origin for the carbonate formation. The chlorite-carbonate-pyrite index (CCPI) and the Ishikawa alteration index (AI), applied to the investigated samples show significant differences (CCPI=52.7-57.8; AI=36.1-40.6) indicating their different degree of alteration. According to Nakada et al., 2005, the C13 to C16 dykes represent the feeder dyke from the latest eruption (1991-1995) whereas C8 represents an earlier dyke feeder dyke from an older eruption. Weakest alteration, which was obtained in samples C16-1-5 and C13-2-5, correlates with the alteration

  9. Energy Management Strategies for a Pneumatic-Hybrid Engine Based on Sliding Window Pattern Recognition Stratégies de gestion de l’énergie pour un moteur hybride pneumatique basées sur la reconnaissance du cycle de conduite

    Directory of Open Access Journals (Sweden)

    Ivanco A.

    2009-11-01

    recognition method is based on a correlation function. To improve analysis, all the results obtained with different energy management strategies are compared with a Dynamic Programming approach (DP considered as the optimal solution. Results show that about 40% of fuel saving can be achieved by DP. The VPC and DPR strategies give better results than the CPC strategy, not so far from the results obtained with DP. Cet article présente comparativement des stratégies de gestion de l’énergie pour un nouveau concept de moteur hybride : l’hybride pneumatique. Dans cette configuration spécifique, c’est le moteur lui-même qui est hybridé (et non le véhicule. Plusieurs stratégies de gestion d’énergie sont proposées dans cet article. La première est dite Causale (CS car basée sur des principes heuristiques de décision. La deuxième est basée sur la minimisation d’un critère d’équivalence et est appelée stratégie à Coefficient de Pénalité Constant (CPC. Dans ce cas, les flux d’énergie (depuis chaque source chimique ou pneumatique sont décrits dans des unités identiques. Ainsi, pour un même travail à produire, il est possible de faire une « balance » entre la consommation nécessaire selon chacune des deux sources d’énergie, et ceci avec un coefficient de pondération constant. La troisième stratégie utilise un coefficient de pondération variable selon la quantité d’air disponible dans le réservoir (i.e. état de charge et est appelée stratégie à Coefficient de Pénalité Variable (VPC. Dans ce cas, le coefficient de pénalité est une fonction non-linéaire de la pression dans le réservoir. Un autre raisonnement consiste à considérer qu’il est nécessaire d’adapter également le coefficient à la situation de conduite (embouteillage, urbain, routier, autoroutier..., pour cela il est impératif de reconnaître la situation de conduite. Le coefficient peut alors être adapté, selon la situation reconnue à la valeur optimale pr

  10. Volcanic risk metrics at Mt Ruapehu, New Zealand: some background to a probabilistic eruption forecasting scheme and a cost/benefit analysis at an open conduit volcano

    Science.gov (United States)

    Jolly, Gill; Sandri, Laura; Lindsay, Jan; Scott, Brad; Sherburn, Steve; Jolly, Art; Fournier, Nico; Keys, Harry; Marzocchi, Warner

    2010-05-01

    The Bayesian Event Tree for Eruption Forecasting software (BET_EF) is a probabilistic model based on an event tree scheme that was created specifically to compute long- and short-term probabilities of different outcomes (volcanic unrest, magmatic unrest, eruption, vent location and eruption size) at long-time dormant and routinely monitored volcanoes. It is based on the assumption that upward movements of magma in a closed conduit volcano will produce detectable changes in the monitored parameters at the surface. In this perspective, the goal of BET_EF is to compute probabilities by merging information from geology, models, past data and present monitoring measurements, through a Bayesian inferential method. In the present study, we attempt to apply BET_EF to Mt Ruapehu, a very active and well-monitored volcano exhibiting the typical features of open conduit volcanoes. In such conditions, current monitoring at the surface is not necessarily able to detect short term changes at depth that may occur only seconds to minutes before an eruption. This results in so-called "blue sky eruptions" of Mt Ruapehu (for example in September 2007), that are volcanic eruptions apparently not preceded by any presently detectable signal in the current monitoring. A further complication at Mt Ruapehu arises from the well-developed hydrothermal system and the permanent crater lake sitting on top of the magmatic conduit. Both the hydrothermal system and crater lake may act to mask or change monitoring signals (if present) that magma produces deeper in the edifice. Notwithstanding these potential drawbacks, we think that an attempt to apply BET_EF at Ruapehu is worthwhile, for several reasons. First, with the exception of a few "blue sky" events, monitoring data at Mt Ruapehu can be helpful in forecasting major events, especially if a large amount of magma is intruded into the edifice and becomes available for phreatomagmatic or magmatic eruptions, as for example in 1995-96. Secondly, in

  11. Can nerve regeneration on an artificial nerve conduit be enhanced by ethanol-induced cervical sympathetic ganglion block?

    Directory of Open Access Journals (Sweden)

    Yoshiki Shionoya

    Full Text Available This study aimed to determine whether nerve regeneration by means of an artificial nerve conduit is promoted by ethanol-induced cervical sympathetic ganglion block (CSGB in a canine model. This study involved two experiments-in part I, the authors examined the effect of CSGB by ethanol injection on long-term blood flow to the orofacial region; part II involved evaluation of the effect of CSGB by ethanol injection on inferior alveolar nerve (IAN repair using polyglycolic acid-collagen tubes. In part I, seven Beagles were administered left CSGB by injection of 99.5% ethanol under direct visualization by means of thoracotomy, and changes in oral mucosal blood flow in the mental region and nasal skin temperature were evaluated. The increase in blood flow on the left side lasted for 7 weeks, while the increase in average skin temperature lasted 10 weeks on the left side and 3 weeks on the right. In part II, fourteen Beagles were each implanted with a polyglycolic acid-collagen tube across a 10-mm gap in the left IAN. A week after surgery, seven of these dogs were administered CSGB by injection of ethanol. Electrophysiological findings at 3 months after surgery revealed significantly higher sensory nerve conduction velocity and recovery index (ratio of left and right IAN peak amplitudes after nerve regeneration in the reconstruction+CSGB group than in the reconstruction-only group. Myelinated axons in the reconstruction+CSGB group were greater in diameter than those in the reconstruction-only group. Administration of CSGB with ethanol resulted in improved nerve regeneration in some IAN defects. However, CSGB has several physiological effects, one of which could possibly be the long-term increase in adjacent blood flow.

  12. Can nerve regeneration on an artificial nerve conduit be enhanced by ethanol-induced cervical sympathetic ganglion block?

    Science.gov (United States)

    Sunada, Katsuhisa; Shigeno, Keiji; Nakada, Akira; Honda, Michitaka; Nakamura, Tatsuo

    2017-01-01

    This study aimed to determine whether nerve regeneration by means of an artificial nerve conduit is promoted by ethanol-induced cervical sympathetic ganglion block (CSGB) in a canine model. This study involved two experiments—in part I, the authors examined the effect of CSGB by ethanol injection on long-term blood flow to the orofacial region; part II involved evaluation of the effect of CSGB by ethanol injection on inferior alveolar nerve (IAN) repair using polyglycolic acid-collagen tubes. In part I, seven Beagles were administered left CSGB by injection of 99.5% ethanol under direct visualization by means of thoracotomy, and changes in oral mucosal blood flow in the mental region and nasal skin temperature were evaluated. The increase in blood flow on the left side lasted for 7 weeks, while the increase in average skin temperature lasted 10 weeks on the left side and 3 weeks on the right. In part II, fourteen Beagles were each implanted with a polyglycolic acid-collagen tube across a 10-mm gap in the left IAN. A week after surgery, seven of these dogs were administered CSGB by injection of ethanol. Electrophysiological findings at 3 months after surgery revealed significantly higher sensory nerve conduction velocity and recovery index (ratio of left and right IAN peak amplitudes) after nerve regeneration in the reconstruction+CSGB group than in the reconstruction-only group. Myelinated axons in the reconstruction+CSGB group were greater in diameter than those in the reconstruction-only group. Administration of CSGB with ethanol resulted in improved nerve regeneration in some IAN defects. However, CSGB has several physiological effects, one of which could possibly be the long-term increase in adjacent blood flow. PMID:29220373

  13. AC loss performance of cable-in-conduit conductor. Influence of cable mechanical property on coupling loss reduction

    International Nuclear Information System (INIS)

    Matsui, Kunihiro; Koizumi, Norikiyo; Isono, Takaaki; Hamada, Kazuya; Nunoya, Yoshihiko

    2003-01-01

    The ITER Central Solenoid (CS) model coil, CS Insert and Nb 3 Al Insert were developed and tested from 2000 to 2002. The AC loss performances of these coils were investigated in various experiments. In addition, the AC losses of the CS and Nb 3 Al Insert conductors were measured using short CS and Nb 3 Al Insert conductors before the coil tests. The coupling time constants of these conductors were estimated to be 30 and 120 ms, respectively. On the other hand, the test results of the CS and Nb 3 Al Inserts show that the coupling currents induced in these conductors had multiple decay time constants. In fact, the existence of the coupling currents with long decay time constants, the order of which was in the thousands of seconds, was directly observed with hall sensors and voltage taps. Moreover, the AC loss test results show that electromagnetic force decreases coupling losses with exponential decay constants. This is because the weak sinter among the strands, which originated during heat treatment, was broken due to the electromagnetic force, and then the contact resistance among strands increased. It was found that this exponential decay constant was the function of a gap (i.e., a mechanical property of the cable) created between the cable and conduit due to electromagnetic force. The gap can be estimated by pressure drop, measured under the electromagnetic force. The pressure drop can easily be measured at an initial trial charge, and then it is possible to estimate the exponential decay constant before normal coil operation. Accordingly, it is possible to predict promptly how many times the trial operations are necessary to decrease the coupling losses to the designed value by measuring the coupling losses and the pressure drop during the initial coil operation trial. (author)

  14. Lossless droplet transfer of droplet-based microfluidic analysis

    Science.gov (United States)

    Kelly, Ryan T [West Richland, WA; Tang, Keqi [Richland, WA; Page, Jason S [Kennewick, WA; Smith, Richard D [Richland, WA

    2011-11-22

    A transfer structure for droplet-based microfluidic analysis is characterized by a first conduit containing a first stream having at least one immiscible droplet of aqueous material and a second conduit containing a second stream comprising an aqueous fluid. The interface between the first conduit and the second conduit can define a plurality of apertures, wherein the apertures are sized to prevent exchange of the first and second streams between conduits while allowing lossless transfer of droplets from the first conduit to the second conduit through contact between the first and second streams.

  15. Wärme- und Stoffaustauschreaktor

    OpenAIRE

    Laevemann, E.; Kessling, W.; Heinzl, W.; Jung, D.; Sitzmann, R.

    1994-01-01

    The description refers to a heat and mass transfer reactor comprising two conduit systems separated from one another by mass, of which one conduit system (heat exchange conduit system) is swept by a fluid or gaseous heating or cooling medium A and the other conduit system (mass transfer conduit system) is swept by a gaseous medium B and another fluid medium C. The reactor according to the invention is characterized by the fact that the heat exchange conduit system is arranged horizontally and...

  16. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  17. Use of a Y-tube conduit after facial nerve injury reduces collateral axonal branching at the lesion site but neither reduces polyinnervation of motor endplates nor improves functional recovery.

    Science.gov (United States)

    Hizay, Arzu; Ozsoy, Umut; Demirel, Bahadir Murat; Ozsoy, Ozlem; Angelova, Srebrina K; Ankerne, Janina; Sarikcioglu, Sureyya Bilmen; Dunlop, Sarah A; Angelov, Doychin N; Sarikcioglu, Levent

    2012-06-01

    Despite increased understanding of peripheral nerve regeneration, functional recovery after surgical repair remains disappointing. A major contributing factor is the extensive collateral branching at the lesion site, which leads to inaccurate axonal navigation and aberrant reinnervation of targets. To determine whether the Y tube reconstruction improved axonal regrowth and whether this was associated with improved function. We used a Y-tube conduit with the aim of improving navigation of regenerating axons after facial nerve transection in rats. Retrograde labeling from the zygomatic and buccal branches showed a halving in the number of double-labeled facial motor neurons (15% vs 8%; P facial-facial anastomosis coaptation. However, in both surgical groups, the proportion of polyinnervated motor endplates was similar (≈ 30%; P > .05), and video-based motion analysis of whisking revealed similarly poor function. Although Y-tube reconstruction decreases axonal branching at the lesion site and improves axonal navigation compared with facial-facial anastomosis coaptation, it fails to promote monoinnervation of motor endplates and confers no functional benefit.

  18. Advanced data processing of airborne electromagnetic data for imaging hidden conduit networks in the coastal karst plain of Tulum (Mexico)

    International Nuclear Information System (INIS)

    Schiller, A.; Schattauer, I.; Ottowitz, D.

    2016-01-01

    This study is part of a series of international research cooperations which commenced in 2007 and are still ongoing. The study area is located on the east coast of the Yucatan Peninsula, Mexico, and comprises the northern most part of the Sian Kaan biosphere reserve, a coastal wetland of international importance, as well as the city of Tulum in the state of Quintana Roo, and part of the second largest barrier reef in the world some 300 metres to one kilometre off shore. Two airborne surveys, conducted in 2007 and 2008 by the Geological Survey of Austria, covered an area of some 200 square kilometres, including the well-known Ox Bel Ha cave system, already mapped by exploration divers. In order to get additional ground truth data and input for the hydrological model, extended ground geophysical campaigns have been conducted an - nually. The first processing of the airborne electromagnetic (AEM) data revealed not only a clear signature from known caves but also the image of a vast, unexplored, hidden conduit network. However, lateral and depth resolution was limited due to measurement drift and noise as well the specific behaviour of the ap - plied inversion technique. Newly developed algorithms for processing AEM data and inversion results have improved the signal-to-noise ratio significantly and enabled the imaging of well defined structures in the underground. Therefore, the AEM method is now capable of quickly deliver crucial structural information of karst-water regimes in difficult accessible areas with unique depth information compared to previous studies. (Author)

  19. Molten salt as a heat transfer fluid for heating a subsurface formation

    Science.gov (United States)

    Nguyen, Scott Vinh; Vinegar, Harold J.

    2010-11-16

    A heating system for a subsurface formation includes a conduit located in an opening in the subsurface formation. An insulated conductor is located in the conduit. A material is in the conduit between a portion of the insulated conductor and a portion of the conduit. The material may be a salt. The material is a fluid at operating temperature of the heating system. Heat transfers from the insulated conductor to the fluid, from the fluid to the conduit, and from the conduit to the subsurface formation.

  20. submitter Development of Joint Terminals for a New Six-Around-One ReBCO-CORC Cable-in-Conduit Conductor Rated 45 kA at 10T/4K

    CERN Document Server

    Mulder, Tim; Mentink, Matthias; Dhalle, Marc; Ten Kate, Herman

    2016-01-01

    The European Organization for Nuclear Research (CERN) is developing a six-around-one conductor on round core (CORC)-strand-based cable-in-conduit conductor (CICC) for use in detector and other large magnet systems. The CICC comprises six ReBCO-CORC strands helically wound around a central tube or rod and inserted in a square aluminum jacket. A major design challenge is finding a simple yet low-resistive method of injecting current homogeneously into the CORC strands of the CICC. In the production of joints for single-CORC cables, we are currently pursuing a method in which the different ReBCO layers at both ends of the CORC cable are trimmed into a staircase-like geometry. A similar trimming method is developed for joint terminals for the ReBCO-CORC-based CICC. A demonstration joint terminal is made to test the various steps of the trimming and manufacturing process before fabricating a joint terminal with real CORC strands. This paper presents an overview of CIC-joint terminal design, simulation results, and...

  1. International tax planning & prevention of abuse under domestic tax law, tax treaties & EC-law

    OpenAIRE

    De Broe, Luc

    2007-01-01

    PART ONE:THE USE OF CONDUIT & BASE COMPANIES IN INTERNATIONAL TAX PLANNING 1 1. CONDUIT COMPANIES 1 1.1. Treaty shopping 1 1.1.1. Description of the term “Treaty shopping” in relation to conduit companies 1 1.1.2. Basic features of “Treaty Shopping” in relation to conduit companies 6 1.1.2.1. Form of the conduit: company or partnership ? 6 1.1.2.2. Tax considerations in setting up the conduit 8 1.2. Directive shopping 11 1.2.1. Description of the term ...

  2. Heating systems for heating subsurface formations

    Science.gov (United States)

    Nguyen, Scott Vinh [Houston, TX; Vinegar, Harold J [Bellaire, TX

    2011-04-26

    Methods and systems for heating a subsurface formation are described herein. A heating system for a subsurface formation includes a sealed conduit positioned in an opening in the formation and a heat source. The sealed conduit includes a heat transfer fluid. The heat source provides heat to a portion of the sealed conduit to change phase of the heat transfer fluid from a liquid to a vapor. The vapor in the sealed conduit rises in the sealed conduit, condenses to transfer heat to the formation and returns to the conduit portion as a liquid.

  3. A hyaluronan-based nerve guide : in vitro cytotoxicity, subcutaneous tissue reactions, and degradation in the rat

    NARCIS (Netherlands)

    Jansen, K; van Wachem, PB; Nicolai, JPA; de Leij, LFMH; van Luyn, MJA; van der Werf, J.F.A.

    We investigated possible cytotoxic effects, biocompatibility, and degradation of a hyaluronan-based conduit for peripheral nerve repair. We subjected the conduits to an in vitro fibroblast cytotoxicity test and concluded that the conduits were not cytotoxic. Subsequently, we implanted the conduits

  4. Apparatus and method for maintaining multi-component sample gas constituents in vapor phase during sample extraction and cooling

    Science.gov (United States)

    Felix, Larry Gordon; Farthing, William Earl; Irvin, James Hodges; Snyder, Todd Robert

    2010-05-11

    A dilution apparatus for diluting a gas sample. The apparatus includes a sample gas conduit having a sample gas inlet end and a diluted sample gas outlet end, and a sample gas flow restricting orifice disposed proximate the sample gas inlet end connected with the sample gas conduit and providing fluid communication between the exterior and the interior of the sample gas conduit. A diluted sample gas conduit is provided within the sample gas conduit having a mixing end with a mixing space inlet opening disposed proximate the sample gas inlet end, thereby forming an annular space between the sample gas conduit and the diluted sample gas conduit. The mixing end of the diluted sample gas conduit is disposed at a distance from the sample gas flow restricting orifice. A dilution gas source connected with the sample gas inlet end of the sample gas conduit is provided for introducing a dilution gas into the annular space, and a filter is provided for filtering the sample gas. The apparatus is particularly suited for diluting heated sample gases containing one or more condensable components.

  5. Catalytic reactor for low-Btu fuels

    Science.gov (United States)

    Smith, Lance; Etemad, Shahrokh; Karim, Hasan; Pfefferle, William C.

    2009-04-21

    An improved catalytic reactor includes a housing having a plate positioned therein defining a first zone and a second zone, and a plurality of conduits fabricated from a heat conducting material and adapted for conducting a fluid therethrough. The conduits are positioned within the housing such that the conduit exterior surfaces and the housing interior surface within the second zone define a first flow path while the conduit interior surfaces define a second flow path through the second zone and not in fluid communication with the first flow path. The conduit exits define a second flow path exit, the conduit exits and the first flow path exit being proximately located and interspersed. The conduits define at least one expanded section that contacts adjacent conduits thereby spacing the conduits within the second zone and forming first flow path exit flow orifices having an aggregate exit area greater than a defined percent of the housing exit plane area. Lastly, at least a portion of the first flow path defines a catalytically active surface.

  6. The QBO as potential amplifier and conduit to lower altitudes of solar cycle influence

    Directory of Open Access Journals (Sweden)

    H. G. Mayr

    2007-06-01

    tapping the momentum from the upward propagating gravity waves. Influenced and amplified by wave processes, the QBO thus acts as conduit to transfer to lower altitudes the larger SC variations in the UV absorbed in the mesosphere. Our model produces in the temperature variations of the QBO and EAO measurable SC modulations at polar latitudes near the tropopause. The effects are apparently generated by the meridional circulation, and planetary waves presumably, which redistribute the energy from the equatorial region where the waves are very effective in amplifying the SC influence.

  7. Clean Sampling of an Englacial Conduit at Blood Falls, Antarctica - Some Experimental and Numerical Results

    Science.gov (United States)

    Kowalski, Julia; Francke, Gero; Feldmann, Marco; Espe, Clemens; Heinen, Dirk; Digel, Ilya; Clemens, Joachim; Schüller, Kai; Mikucki, Jill; Tulaczyk, Slawek M.; Pettit, Erin; Berry Lyons, W.; Dachwald, Bernd

    2017-04-01

    results of its deployment at Blood Falls. In contrast to conventional melting-probe applications, which can only melt vertically, the IceMole realized an oblique melting path to penetrate the englacial conduit. Experimental and numerical results on melting at oblique angles are rare. Besides reporting on the IceMole technology and the field deployment itself, we will compare and discuss the observed melting behavior with re-analysis results in the context of a recently developed numerical model. Finally, we will present our first steps in utilizing the model to infer on the ambient cryo-environment.

  8. Kinetic energy absorbing pad

    International Nuclear Information System (INIS)

    Bricmont, R.J.; Hamilton, P.A.; Ming Long Ting, R.

    1981-01-01

    Reactors, fuel processing plants etc incorporate pipes and conduits for fluids under high pressure. Fractures, particularly adjacent to conduit elbows, produce a jet of liquid which whips the broken conduit at an extremely high velocity. An enormous impact load would be applied to any stationary object in the conduit's path. The design of cellular, corrugated metal impact pads to absorb the kinetic energy of the high velocity conduits is given. (U.K.)

  9. Harmonic scalpel versus electrocautery for harvest of radial artery conduits: Reduced risk of spasm and intimal injury on optical coherence tomography

    Science.gov (United States)

    Brazio, Philip S.; Laird, Patrick C.; Xu, Chenyang; Gu, Junyan; Burris, Nicholas S.; Brown, Emile N.; Kon, Zachary N.; Poston, Robert S.

    2009-01-01

    Objective Vasospasm is the primary obstacle to widespread adoption of the radial artery as a conduit in coronary artery bypass grafting. We used optical coherence tomography, a catheter-based intravascular imaging modality, to measure the degree of radial artery spasm induced by means of harvest with electrocautery or a harmonic scalpel in patients undergoing coronary artery bypass grafting. Methods Radial arteries were harvested from 44 consecutive patients with a harmonic scalpel (n = 15) or electrocautery (n = 29). Vessels were imaged before harvesting and after removal from the arm, with saphenous vein tracts serving as internal controls. Optical coherence tomographic findings for the degree of harvesting-induced injury were validated against histologic measures. Results Optical coherence tomographic measures of endovascular dimensions and injury correlated strongly with histologic findings. Mean luminal volume, a measure of vasospasm, decreased significantly less after harvesting with a harmonic scalpel (9% ± 7%) than with electrocautery (35% ± 6%, P = .015). Completely intact intima was present in 11 (73%) of 15 radial arteries harvested with a harmonic scalpel (73%) compared with 9 of 29 arteries harvested by means of electrocautery (31%, P = .011). Intraoperative flow measurements and patency rates at 5 days postoperatively were not significantly different among groups. Conclusions Optical coherence tomography provides a level of speed and accuracy for quantifying endothelial injury and vasospasm that has not been described for any other modality, suggesting potential as an intraoperative quality assurance tool. Our optical coherence tomographic findings suggest that the harmonic scalpel induces less spasm and intimal injury compared with electrocautery. PMID:19026820

  10. ProSeal laryngeal mask airway improves oxygenation when used as a conduit prior to laryngoscope guided intubation in bariatric patients

    Directory of Open Access Journals (Sweden)

    Aparna Sinha

    2013-01-01

    Full Text Available Background: The primary objective of this study was to compare the effect of ventilation using the ProSeal TM laryngeal mask airway (PLMA with facemask and oropharyngeal airway (FM, prior to laryngoscopy, on arterial oxygenation in morbidly obese patients undergoing bariatric surgery. Methods: Forty morbidly obese patients were randomly recruited to either PLMA or FM. After pre-oxygenation (FiO 2 1.0 in the ramp position with continuous positive airway pressure of 10 cm H 2 O for 5 min, anaesthesia was induced. Following loss of jaw thrust oropharyngeal airway, the FM and PLMA were inserted. On achieving paralysis, volume control ventilation with PEEP (5 cm H 2 O was initiated. The difficulty in mask ventilation (DMV in FM, number of attempts at PLMA and laryngoscopy were graded (Cormack and Lehane in all patients. Time from onset of laryngoscopy to endotracheal tube confirmation was recorded. Hypoxia was defined as mild (SpO 2 ≤95%, moderate (SpO 2 ≤90% and severe (SpO 2 ≤85%. Results: Significant rise in pO 2 was observed within both groups ( P=0.001, and this was significantly higher in the PLMA ( P=0.0001 when compared between the groups. SpO 2 ≥ 90% ( P=0.018 was seen in 19/20 (95% patients in PLMA and 13/20 (65% in FM at confirmation of tracheal tube. A strong association was found between DMV and Cormack Lehane in the FM group and with number of attempts in the PLMA group. No adverse events were observed. Conclusion: ProSeal TM laryngeal mask airway as conduit prior to laryngoscopy in morbidly obese patients seems effective in increasing oxygen reserves, and can be suggested as a routine airway management technique when managing the airway in the morbidly obese.

  11. Combination gas-producing and waste-water disposal well. [DOE patent application

    Science.gov (United States)

    Malinchak, R.M.

    1981-09-03

    The present invention is directed to a waste-water disposal system for use in a gas recovery well penetrating a subterranean water-containing and methane gas-bearing coal formation. A cased bore hole penetrates the coal formation and extends downwardly therefrom into a further earth formation which has sufficient permeability to absorb the waste water entering the borehole from the coal formation. Pump means are disposed in the casing below the coal formation for pumping the water through a main conduit towards the water-absorbing earth formation. A barrier or water plug is disposed about the main conduit to prevent water flow through the casing except for through the main conduit. Bypass conduits disposed above the barrier communicate with the main conduit to provide an unpumped flow of water to the water-absorbing earth formation. One-way valves are in the main conduit and in the bypass conduits to provide flow of water therethrough only in the direction towards the water-absorbing earth formation.

  12. Combination gas producing and waste-water disposal well

    Science.gov (United States)

    Malinchak, Raymond M.

    1984-01-01

    The present invention is directed to a waste-water disposal system for use in a gas recovery well penetrating a subterranean water-containing and methane gas-bearing coal formation. A cased bore hole penetrates the coal formation and extends downwardly therefrom into a further earth formation which has sufficient permeability to absorb the waste water entering the borehole from the coal formation. Pump means are disposed in the casing below the coal formation for pumping the water through a main conduit towards the water-absorbing earth formation. A barrier or water plug is disposed about the main conduit to prevent water flow through the casing except for through the main conduit. Bypass conduits disposed above the barrier communicate with the main conduit to provide an unpumped flow of water to the water-absorbing earth formation. One-way valves are in the main conduit and in the bypass conduits to provide flow of water therethrough only in the direction towards the water-absorbing earth formation.

  13. Análise do tratamento cirúrgico da raiz da aorta com o tubo valvulado e com a preservação da valva aórtica Analysis of aortic root surgery with composite mechanical aortic valve conduit and valve-sparing reconstruction

    Directory of Open Access Journals (Sweden)

    Ricardo Ribeiro Dias

    2010-12-01

    Full Text Available OBJETIVO: Análise comparativa dos resultados imediatos e tardios da reconstrução da raiz da aorta com o tubo valvulado e com a preservação da valva aórtica. MÉTODOS: No período de novembro de 2002 a setembro de 2009, 164 pacientes com idade média de 54 ± 15 anos, sendo 115 do sexo masculino, foram submetidos ao tratamento cirúrgico da raiz da aorta. Foram 125 tubos valvulados e 39 reconstruções da raiz da aorta com preservação da valva aórtica. Dezesseis por cento dos pacientes eram portadores de síndrome de Marfan e 4,3% apresentavam valva aórtica bivalvulada. Cento e quarenta e quatro (88% pacientes foram acompanhados durante tempo médio de seguimento de 41,1 ± 20,8 meses. RESULTADOS: A mortalidade hospitalar total foi de 4,9%; sendo 5,6% nas operações com tubo valvulado e 2,6% nas preservações da valva aórtica (POBJECTIVE: Comparative analysis of early and late results of aortic root reconstruction with aortic valve sparing operations and the composite mechanical valve conduit replacement. METHODS: From November 2002 to September 2009, 164 consecutive patients with mean age 54 ± 15 years, 115 male, underwent the aortic root reconstruction (125 mechanical valve conduit replacements and 39 valve sparing operations. Sixteen percent of patients had Marfan syndrome and 4.3% had bicuspid aortic valve. One hundred and forty-four patients (88% were followed for a mean period of 41.1 ± 20.8 months. RESULTS: The hospital mortality was 4.9%, 5.6% in operations with valved conduits and 2.6% in the valve sparing procedures (P <0.05. There was no difference neither in survival (95% CI = 86% - 96%, P= 0.1 nor in reoperation-free survival (95% CI = 85% - 90%, P = 0.29. The survival free of complications such as bleeding, thromboembolism and endocarditis were favorable to the valve sparing operations, respectively (95% CI = 70% - 95%, P = 0.001, (95% CI = 82% - 95% P = 0.03 and (95% CI = 81% - 95%, P = 0.03. Multivariate analysis

  14. Wave energy transmission apparatus for high-temperature environments

    Science.gov (United States)

    Buckley, John D. (Inventor); Edwards, William C. (Inventor); Kelliher, Warren C. (Inventor); Carlberg, Ingrid A. (Inventor)

    2010-01-01

    A wave energy transmission apparatus has a conduit made from a refractory oxide. A transparent, refractory ceramic window is coupled to the conduit. Wave energy passing through the window enters the conduit.

  15. Flow through in situ reactors with suction lysimeter sampling capability and methods of using

    Science.gov (United States)

    Radtke, Corey W [Idaho Falls, ID; Blackwelder, D Brad [Blackfoot, ID; Hubbell, Joel M [Idaho Falls, ID

    2009-11-17

    An in situ reactor for use in a geological strata includes a liner defining a centrally disposed passageway and a sampling conduit received within the passageway. The sampling conduit may be used to receive a geological speciment derived from geological strata therein and a lysimeter is disposed within the sampling conduit in communication with the geological specimen. Fluid may be added to the geological specimen through the passageway defined by the liner, between an inside surface of the liner and an outside surface of the sampling conduit. A distal portion of the sampling conduit may be in fluid communication with the passageway.

  16. Radioactive wastes processing device

    International Nuclear Information System (INIS)

    Takamura, Yoshiyuki; Fukujoji, Seiya.

    1986-01-01

    Purpose: To exactly recognize the deposition state of mists into conduits thereby effectively conduct cleaning. Constitution: A drier for performing drying treatment of liquid wastes, a steam decontaminating tower for decontaminating the steams generated from the drier and a condenser for condensating the decontaminating steams are connected with each other by means of conduits to constitute a radioactive wastes processing apparatus. A plurality of pressure detectors are disposed to the conduits, the pressure loss within the conduits is determined based on the detector output and the clogged state in the conduits due to the deposition of mists is detected by the magnitude of the pressure loss. If the clogging exceeds a certain level, cleaning water is supplied to clean-up the conduits thereby keep the operation to continue always under sound conditions. (Sekiya, K.)

  17. Exhaust gas recirculation system for an internal combustion engine

    Science.gov (United States)

    Wu, Ko-Jen

    2013-05-21

    An exhaust gas recirculation system for an internal combustion engine comprises an exhaust driven turbocharger having a low pressure turbine outlet in fluid communication with an exhaust gas conduit. The turbocharger also includes a low pressure compressor intake and a high pressure compressor outlet in communication with an intake air conduit. An exhaust gas recirculation conduit fluidly communicates with the exhaust gas conduit to divert a portion of exhaust gas to a low pressure exhaust gas recirculation branch extending between the exhaust gas recirculation conduit and an engine intake system for delivery of exhaust gas thereto. A high pressure exhaust gas recirculation branch extends between the exhaust gas recirculation conduit and the compressor intake and delivers exhaust gas to the compressor for mixing with a compressed intake charge for delivery to the intake system.

  18. Conduit grinding apparatus

    Science.gov (United States)

    Nachbar, Henry D.; Korytkowski, Alfred S.

    1991-01-01

    A grinding apparatus for grinding the interior portion of a valve stem receiving area of a valve. The apparatus comprises a faceplate, a plurality of cams mounted to an interior face of the faceplate, a locking bolt to lock the faceplate at a predetermined position on the valve, a movable grinder and a guide tube for positioning an optical viewer proximate the area to be grinded. The apparatus can either be rotated about the valve for grinding an area of the inner diameter of a valve stem receiving area or locked at a predetermined position to grind a specific point in the receiving area.

  19. Using Integrated 2D and 3D Resistivity Imaging Methods for Illustrating the Mud-Fluid Conduits of the Wushanting Mud Volcanoes in Southwestern Taiwan

    Directory of Open Access Journals (Sweden)

    Ping-Yu Chang

    2011-01-01

    Full Text Available We conducted 2D and 3D looped resistivity surveys in the Wushanting Natural Landscape Preservation Area (WNLPA in order to understand the relationships of the mud-fluid conduits in the mud volcano system. 2D resistivity surveys were conducted along seven networked lines. Two separate C-shape looped electrode arrays surrounding the volcano craters were used in the study. First, the two 3D looped measurements were inverted separately. Yet the inverted 3D images of the mud-volcano system were inconsistent with the landscape features suggesting that artifacts perhaps appeared in the images. The 3D looped data were then combined with the 2D data for creating a global resistivity model of WNLPA. The resulting 3D image is consistent with the observed landscape features. With the resistivity model of WNLPA, we further tried to estimate the distribution of water content. The results suggest that the 3D resistivity image has the potential to resolve the dual porosity structures in the mudstone area. Last, we used a simplified WNLPA model for forward simulation in order to verify the field measurement results. We have concluded that the artifacts in the 3D looped images are in fact shadow effects from conductive objects out of the electrode loops, and that inverted images of combined 2D and 3D data provide detailed regional conductive structures in the WNLPA site.

  20. Explosive actuated valve

    International Nuclear Information System (INIS)

    Byrne, K.G.

    1983-01-01

    1. A device of the character described comprising the combination of a housing having an elongate bore and including a shoulder extending inwardly into said bore, a single elongate movable plunger disposed in said bore including an outwardly extending flange adjacent one end thereof overlying said shoulder, normally open conduit means having an inlet and an outlet perpendicularly piercing said housing intermediate said shoulder and said flange and including an intermediate portion intersecting and normally openly communicating with said bore at said shoulder, normally closed conduit means piercing said housing and intersecting said bore at a location spaced from said normally open conduit means, said elongate plunger including a shearing edge adjacent the other end thereof normally disposed intermediate both of said conduit means and overlying a portion of said normally closed conduit means, a deformable member carried by said plunger intermediate said flange and said shoulder and normally spaced from and overlying the intermediate portion of said normally open conduit means, and means on the housing communicating with the bore to retain an explosive actuator for moving said plunger to force the deformable member against the shoulder and extrude a portion of the deformable member out of said bore into portions of the normally open conduit means for plugging the same and to effect the opening of said normally closed conduit means by the plunger shearing edge substantially concomitantly with the plugging of the normally open conduit means

  1. Apparatus and method for determining the hydrogen content of a substance

    International Nuclear Information System (INIS)

    Aggour, M.A.; Banerjee, S.

    1984-01-01

    For monitoring the concentration of a hydrogenous component within a given sample or space eg steam quality within a steam conduit. A fast neutron source is positioned proximate the conduit. A moderating element equivalent to a thickness of at least 1 cm of water is situated intermediate the source and conduit for softening the neutron spectrum incident to the conduit. Two neutron detectors are positioned at opposite sides of the conduit, each being spaced an equal radial distance from the source. Means are provided for establishing from the rate of neutron detection and certain other physical properties of the sample data concerning the concentration or disposition of a hydrogenous component of the sample. The source, detectors, and conduit are surrounded by a neutron reflector of neutron moderating material. A screen may be placed around the source to remove most of thermal neutrons so that predominantly epithermal neutrons reach the conduit. To obtain the rate of thermal neutron detection signals from a detector shielded to render it sensitive only to fast and epithermal neutrons are subtracted from those from an unshielded detector. (author)

  2. Guided acoustic wave inspection system

    Science.gov (United States)

    Chinn, Diane J.

    2004-10-05

    A system for inspecting a conduit for undesirable characteristics. A transducer system induces guided acoustic waves onto said conduit. The transducer system detects the undesirable characteristics of the conduit by receiving guided acoustic waves that contain information about the undesirable characteristics. The conduit has at least two sides and the transducer system utilizes flexural modes of propagation to provide inspection using access from only the one side of the conduit. Cracking is detected with pulse-echo testing using one transducer to both send and receive the guided acoustic waves. Thinning is detected in through-transmission testing where one transducer sends and another transducer receives the guided acoustic waves.

  3. Evaluation of the Energy Efficiency of a Fleet of Electric Vehicle for Eco-Driving Application Évaluation de l’efficacité énergétique d’une flotte de véhicules électriques dédiée à une application d’éco-conduite

    Directory of Open Access Journals (Sweden)

    Dib W.

    2012-09-01

    Full Text Available In this paper, an approach to evaluate the energy efficiency of an electrical vehicle during a short trip is addressed. This approach provides metrics that can be used to evaluate the potential of improvement achievable via intelligent eco-driving techniques and the performance actually achieved by any of them. It can be the basis for an evaluation of a fleet of vehicles and of a whole city for which an energy efficiency map could be derived, depending for instance of traffic management strategy. Experimental data are provided to illustrate the approach for a fleet of electric vehicles in an urban environment. The methods proposed are intended to be the basis of a driver assistance system oriented to optimal eco-driving. Dans cet article, nous proposons une approche pour évaluer l’efficacité énergétique d’un véhicule électrique lors d’un déplacement urbain. Cette approche fournit des outils permettant d’évaluer le gain énergétique réalisable par l’intermédiaire des techniques intelligentes d’éco-conduite. Cette approche peut être utilisée pour évaluer une flotte de véhicules, ainsi que pour élaborer une cartographie énergétique d’une ville. Des données expérimentales sont fournies pour illustrer cette approche sur une flotte de véhicules électriques dans un environnement urbain. Les méthodes d’éco-conduite proposées sont destinées à constituer la base d’un système d’assistance au conducteur.

  4. Perinatal development influences mechanisms of bradykinin-induced relaxations in pulmonary resistance and conduit arteries differently.

    Science.gov (United States)

    Boels, P J; Deutsch, J; Gao, B; Haworth, S G

    2001-07-01

    As bradykinin (BYK) relaxes conduit (EPA) and resistance (RPA) pulmonary arteries from both perinatal and adult lungs, we investigated whether this vasodilator's relaxation-mechanisms were altered during perinatal development, differed between EPA and RPA and differed with other endothelium-dependent vasodilators, acetyicholine (ACH) and substance P (SP). Arteries from mature foetal (5 days), neonatal (approximately 5 min), newborn (60-84 h) and adult pigs (> or =6 months) were isolated, mounted for in vitro isometric force recording, activated with PGF(2alpha) (30 micromol/l) and relaxed with BYK (10 pmol/l-1 micromol/l), SP (10 pmol/l-0.1 micromol/l) or ACH (1 nmol/l-1 mmol/l). (i) BYK: L-NAME (100 micromol/l) attenuated relaxations in foetal EPA ( approximately 55%) but nearly abolished them in the adult ( approximately 80%). In RPA, L-NAME nearly abolished ( approximately 90%) relaxations in the foetus and this effect diminished progressively with age to approximately 20% in the adult. Indomethacin (IND, micromol/l) attenuated relaxations in neonatal (approximately 25%), new-born and adult EPA (both approximately 45%). Together, L-NAME and IND abolished relaxations in all EPA and in neonatal RPA but not in older RPA. SKF525a (100 micromol/l) attenuated relaxations in foetal RPA ( approximately 4%), diminishing in the adult RPA to approximately 10%. Together, SKF52Sa and L-NAME largely abolished relaxations in postnatal RPA (approximately 80%). Activation with K(+)=125 mmol/l attenuated relaxations in adult EPA (approximately 80%), foetal RPA ( approximately 45%) and neonatal RPA (approximately 75%) and abolished relaxations in RPA from older ages. (ii) ACH: L-NAME abolished relaxations in new-born EPA and RPA. In adult EPA, combined L-NAME and IND moderately attenuated relaxations. (iii) SP: Combined application of L-NAME and IND attenuated relaxations to a similar degree in new-born and adult EPA and RPA. In postnatal EPA, BYK-relaxations depend completely on

  5. The twisted diversion: a paralyzing complication

    OpenAIRE

    Hiew, Kenneth; Glendinning, Richard; Parr, Nigel; Kumar, Manal

    2013-01-01

    Ileal conduit remains a widely used urinary diversion performed after radical cystectomy. However, complications of ileal conduits remain an important concern in urological surgery. We report a rare case of an ileal conduit stricture, which can have grim complications if unobserved during the operation. Following an initial operation of radical cystectomy and ileal conduit formation in France in 2011, an 80-year-old male travelled back to the UK after 4 months of general weakness and limb par...

  6. Real-time airborne particle analyzer

    Science.gov (United States)

    Reilly, Peter T.A.

    2012-10-16

    An aerosol particle analyzer includes a laser ablation chamber, a gas-filled conduit, and a mass spectrometer. The laser ablation chamber can be operated at a low pressure, which can be from 0.1 mTorr to 30 mTorr. The ablated ions are transferred into a gas-filled conduit. The gas-filled conduit reduces the electrical charge and the speed of ablated ions as they collide and mix with buffer gases in the gas-filled conduit. Preferably, the gas filled-conduit includes an electromagnetic multipole structure that collimates the nascent ions into a beam, which is guided into the mass spectrometer. Because the gas-filled conduit allows storage of vast quantities of the ions from the ablated particles, the ions from a single ablated particle can be analyzed multiple times and by a variety of techniques to supply statistically meaningful analysis of composition and isotope ratios.

  7. Poly(D,L-Lactide-Co-Glycolide) Tubes With Multifilament Chitosan Yarn or Chitosan Sponge Core in Nerve Regeneration.

    Science.gov (United States)

    Wlaszczuk, Adam; Marcol, Wiesław; Kucharska, Magdalena; Wawro, Dariusz; Palen, Piotr; Lewin-Kowalik, Joanna

    2016-11-01

    The influence of different kinds of nerve guidance conduits on regeneration of totally transected rat sciatic nerves through a 7-mm gap was examined. Five different types of conduits made of chitosan and poly(D,L-lactide-co-glycolide) (PLGA) were constructed and tested in vivo. We divided 50 animals into equal groups of 10, with a different type of conduit implanted in each group: chitosan sponge core with an average molecular mass of polymer (Mv) of 287 kDa with 7 channels in a PLGA sleeve, chitosan sponge core with an Mv of 423 kDa with 7 channels in a PLGA sleeve, chitosan sponge core (Mv, 423 kDa) with 13 channels in a PLGA sleeve, chitosan multifilament yarn in a PLGA sleeve, and a PLGA sleeve only. Seven weeks after the operation, we examined the distance covered by regenerating nerve fibers, growing of nerves into the conduit's core, and intensity and type of inflammatory reaction in the conduit, as well as autotomy behavior (reflecting neuropathic pain intensity) in the animals. Two types of conduits were allowing nerve outgrowth through the gap with minor autotomy and minor inflammatory reactions. These were the conduits with chitosan multifilament yarn in a PLGA sleeve and the conduits with 13-channel microcrystalline chitosan sponge in a PLGA sleeve. The type of chitosan used to build the nerve guidance conduit influences the intensity and character of inflammatory reaction present during nerve regeneration, which in turn affects the distance crossed by regenerating nerve fibers, growing of the nerve fibers into the conduit's core, and the intensity of autotomy in the animals. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  8. NRC Information Notice No. 92-01: Cable damage caused by inadequate cable installation procedures and controls

    International Nuclear Information System (INIS)

    Rossi, C.E.

    1993-01-01

    In June 1989, the Tennessee Valley Authority (TVA) removed the cables from a conduit in the reactor protection system of the Watts Bar Nuclear Plant, Unit 2, to inspect for damage. TVA selected this conduit in response to an employee's concern that a welding arc that struck the conduit in response to an employee's concern that a welding arc that struck the conduit during construction may have damaged cables in the conduit. When the cables were removed, TVA found significant damage in the insulation of some cables. This damage was not attributed to heat generated by the alleged welding arc. The damage was principally attributed to the pulling stresses exerted during the initial installation of the cables. Some of the cables had insulation removed down to the conductors. To assess the extent of cable damage and determine the scope of its investigation, TVA removed more cables from conduits that constituted the most difficult pulls (worst case) and found varying degrees of damage that it attributed to pulling stresses. To fill a conduit at Watts Bar, personnel used pull cords to pull more cables through the conduits over the top of existing cables. This practice is called ''pull-by.'' This practice can cause damage to the existing cables from the sawing action of the pull cords and the friction of cables as they are pulled over existing cables. TVA instituted programs to assess the adequacy of cable installation at all its nuclear facilities and take appropriate corrective actions. At Watts Bar, TVA replaced cables in conduits which exceeded a calculated threshold value of side wall bearing pressure (SWBP) and performed a high-potential (hi-pot) tests on a number of other cables in conduits with SWBP below the calculated threshold value

  9. Spatially varying dispersion to model breakthrough curves.

    Science.gov (United States)

    Li, Guangquan

    2011-01-01

    Often the water flowing in a karst conduit is a combination of contaminated water entering at a sinkhole and cleaner water released from the limestone matrix. Transport processes in the conduit are controlled by advection, mixing (dilution and dispersion), and retention-release. In this article, a karst transport model considering advection, spatially varying dispersion, and dilution (from matrix seepage) is developed. Two approximate Green's functions are obtained using transformation of variables, respectively, for the initial-value problem and for the boundary-value problem. A numerical example illustrates that mixing associated with strong spatially varying conduit dispersion can cause strong skewness and long tailing in spring breakthrough curves. Comparison of the predicted breakthrough curve against that measured from a dye-tracing experiment between Ames Sink and Indian Spring, Northwest Florida, shows that the conduit dispersivity can be as large as 400 m. Such a large number is believed to imply strong solute interaction between the conduit and the matrix and/or multiple flow paths in a conduit network. It is concluded that Taylor dispersion is not dominant in transport in a karst conduit, and the complicated retention-release process between mobile- and immobile waters may be described by strong spatially varying conduit dispersion. Copyright © 2010 The Author(s). Journal compilation © 2010 National Ground Water Association.

  10. Compressive pre-strain in Nb3Sn strand by steel tube and effect on the critical current measured on standard ITER barrel

    NARCIS (Netherlands)

    Nijhuis, Arend; Wessel, Wilhelm A.J.; Knoopers, H.G.; Ilyin, Y.; ten Kate, Herman H.J.; Della Corte, A.

    2005-01-01

    The large Cable-In-Conduit Conductors (CICC) designed for the magnet coils in the International Thermonuclear Experimental Reactor (ITER), are composed of Nb/sub 3/Sn strand bundles in a Stainless Steel (SS) or Incoloy conduit. Both, the thermal contraction of the strand composite and the conduit

  11. Sampling system and method

    Science.gov (United States)

    Decker, David L.; Lyles, Brad F.; Purcell, Richard G.; Hershey, Ronald Lee

    2013-04-16

    The present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit.

  12. Ball assisted device for analytical surface sampling

    Science.gov (United States)

    ElNaggar, Mariam S; Van Berkel, Gary J; Covey, Thomas R

    2015-11-03

    A system for sampling a surface includes a sampling probe having a housing and a socket, and a rolling sampling sphere within the socket. The housing has a sampling fluid supply conduit and a sampling fluid exhaust conduit. The sampling fluid supply conduit supplies sampling fluid to the sampling sphere. The sampling fluid exhaust conduit has an inlet opening for receiving sampling fluid carried from the surface by the sampling sphere. A surface sampling probe and a method for sampling a surface are also disclosed.

  13. Secondary air injection system and method

    Science.gov (United States)

    Wu, Ko-Jen; Walter, Darrell J.

    2014-08-19

    According to one embodiment of the invention, a secondary air injection system includes a first conduit in fluid communication with at least one first exhaust passage of the internal combustion engine and a second conduit in fluid communication with at least one second exhaust passage of the internal combustion engine, wherein the at least one first and second exhaust passages are in fluid communication with a turbocharger. The system also includes an air supply in fluid communication with the first and second conduits and a flow control device that controls fluid communication between the air supply and the first conduit and the second conduit and thereby controls fluid communication to the first and second exhaust passages of the internal combustion engine.

  14. Imaging pockets and conduits of low velocity material beneath the lithosphere of the Atlas Mountains of Morocco: links to volcanism and orogenesis

    Science.gov (United States)

    Miller, M. S.; Sun, D.; O'Driscoll, L.; Holt, A.; Butcher, A.; Becker, T. W.; Diaz Cusi, J.; Thomas, C.

    2014-12-01

    The Atlas Mountains of Morocco have unusually high topography, with no apparent deep crustal root, and regions of localized Cenozoic alkaline volcanism. Previous seismic imaging and geophysical studies have implied a hot mantle upwelling as the source of the volcanism and high elevation, but the existence and physical properties of such an upwelling are debated. Recent temporary deployments of over 100 broadband seismometers that extended across Morocco as part of the PICASSO, Morocco-Münster, and IberArray experiments along with select permanent stations have provided a dataset to image the detailed mantle and lithospheric structure beneath the Atlas. We present results from S receiver functions (SRF), shear wave splitting, waveform modeling, and geodynamic models that help constrain the tectonic evolution of the Atlas and the localized alkaline volcanism. The receiver functions show that the lithosphere is thin (~65 km) beneath the Atlas, but thickens (~105 km) over a very short length scale at the flanks of the mountains and near the Quaternary volcanoes. These changes in lithospheric thickness also correspond to dramatic decreases in delay times inferred from S and SKS splitting observations. SRFs also indicate a broad, low seismic velocity anomaly (~150 km) below the shallow lithosphere that extends along much of the Atlas and beneath the Anti-Atlas and correlates with the location of Pliocene-Quaternary magmatism. Waveform analysis from the linear array across the Middle and High Atlas constrains the position, shape, and physical characteristics of a localized, low velocity conduit that extends up from the uppermost mantle (~200 km). The shape, position and temperature of the imaged low velocity anomaly, offsets in the lithosphere-asthenosphere boundary, and correlation with mantle flow inferred from shear wave splitting suggest that the unusually high topography of the Atlas Mountains is due to active mantle support.

  15. S Tank Farm SL-119 saltwell piping failure analysis report

    International Nuclear Information System (INIS)

    Carlos, W.C.

    1994-01-01

    On January 24, 1992, while pressure testing saltwell line SL-119 in the 241-S Tank Farm, water was observed spraying out of heat trace enclosure. The SL-115, SL-116, SN-215, and SN-216 saltwell lines also recently failed pressure testing because of leaks. This study documents the pertinent facts about the SL-119 line and discusses the cause of the failures. The inspection of the SL-119 failure revealed two through-the-wall holes in the top center of the pipeline. The inspection also strongly suggests that the heat tracing system is directly responsible for causing the SL-119 failure. Poor design of the heat tracing system allowed water to enter, condense, and collect in the electric metallic tubing (EMT) carbon steel conduits. Water flowed to the bottom of the elbow of the conduit and corroded out the elbow. The design also allowed drifting desert sand to enter into the conduit and fall to the bottom (elbow) of the conduit. The sand became wet and aided in the corrosion of the elbow of the conduit. After the EMT conduits corroded though, the water dripped from the corroded ends of the EMT conduits onto the top of the saltwell pipe, corroding the two holes into the top of the line. If the heat tracing hot splice box had not allowed moisture to enter the EMT conduits, the saltwell piping would not have corroded and caused SL-119 to fail

  16. Adenocarcinoma in a Koff Urinary Ileal Diversion

    Directory of Open Access Journals (Sweden)

    Bradley Sherman

    2017-07-01

    Full Text Available The use of an ileal conduit as a means of treatment for bladder cancer or dysfunction is widely used and understood. However, long term surveillance of that conduit has not been strongly established and set forth as a means of screening. We present a 76yo female with a history of neurogenic bladder secondary to paraplegia who underwent the formation of a “Koff” pouch as a conduit. Nineteen years later she presents with hematuria and was found to have adenocarcinoma originating in her conduit.

  17. Fluid pipeline leak detection and location with miniature RF tags

    Science.gov (United States)

    McIntyre, Timothy J.

    2017-05-16

    Sensors locate troublesome leaks in pipes or conduits that carry a flowing medium. These sensors, through tailored physical and geometric properties, preferentially seek conduit leaks or breaches due to flow streaming. The sensors can be queried via transceivers outside the conduit or located and interrogated inside by submersible unmanned vehicle to identify and characterize the nature of a leak. The sensors can be functionalized with other capabilities for additional leak and pipeline characterization if needed. Sensors can be recovered from a conduit flow stream and reused for future leak detection activities.

  18. Clinical Outcomes of the David V Valve-Sparing Root Replacement Compared With Bioprosthetic Valve-Conduits for Aortic Root Aneurysms.

    Science.gov (United States)

    Esaki, Jiro; Leshnower, Bradley G; Binongo, Jose N; Lasanajak, Yi; McPherson, LaRonica; Halkos, Michael E; Guyton, Robert A; Chen, Edward P

    2017-06-01

    Valve-sparing root replacement (VSRR) is an established therapy for aortic root pathology. Limited insight exists when the results of VSRR are compared with those of conventional root replacement with use of a bioprosthetic composite conduit (BIO). This study compares the operative and midterm results of VSRR and BIO. A retrospective review from 2002 to 2015 at a United States academic center identified 282 patients who underwent VSRR and 425 patients who underwent BIO. Propensity-score matching was performed based on 20 preoperative characteristics, and 123 matched pairs were identified. The mean age (VSRR 53.5 ± 11.1, BIO 53.0 ± 13.0; p = 0.74) and left ventricular ejection fraction (VSRR 54.5 ± 9.2%, BIO 54.4 ± 9.4%; p = 0.99) were equivalent in both groups. The incidence of bicuspid valves (VSRR 26.0%, BIO 27.6%; p = 0.77), Marfan syndrome (VSRR 6.5%, BIO 4.9%; p = 0.58), type A dissection (VSRR 13.0%, BIO 13.0%; p = 0.99), reoperation (VSRR 15.4%, BIO 20.3%; p = 0.32) and arch replacement (VSRR 60.2%, BIO 63.4%; p = 0.60) were similar between the groups. Operative mortality was 5.7% in VSRR and 0.8% in BIO (p = 0.07). There were no significant differences in postoperative renal failure (VSRR 0.8%, BIO 0.0%; p = 0.99) or stroke (VSRR 3.3%, BIO 0.8%; p = 0.37) between the groups. The 7-year survival (VSSR 82.4%, BIO 83.0%; p = 0.53), 7-year freedom from reoperation (VSRR 97.4%, BIO 95.8%; p = 0.48), and 7-year freedom from greater than moderate aortic insufficiency (AI) (VSRR 98.1%, BIO 100.0%; p = 0.47) were similar between groups. VSRR and BIO result in equivalent operative mortality and morbidity with similar midterm survival and valve durability. VSRR is an effective alternative to BIO for aortic root pathologic conditions; however, careful patient selection is paramount. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Prophylaxis against radiation injury. The use of elemental diet prior to and during radiotherapy for invasive bladder cancer and in early postoperative feeding following radical cystectomy and ileal conduit

    International Nuclear Information System (INIS)

    McArdle, A.H.; Reid, E.C.; Laplante, M.P.; Freeman, C.R.

    1986-01-01

    Previous studies done in animals have shown that significant prophylaxis against radiation injury could be afforded by feeding an elemental diet (ED) for three days before and during radiation. In the present study 20 patients were fed an ED for three days before and for the four days during radiotherapy (five fractions of 400 rad [4 Gy] each) prior to radical cystectomy and ileal conduit for invasive bladder cancer; ED feeding was recommenced 24 hours postoperatively via a feeding jejunostomy. The ED-fed patients exhibited positive nitrogen balance preoperatively and had an early return to positive nitrogen balance postoperatively (3.60 +/- 0.32 days). There was also prompt return of bowel sounds (3.00 +/- 0.32 days). Histologically and ultrastructurally, biopsy specimens of the ileal mucosa showed normal morphologic findings, with maintenance of normal levels of enzyme activity in the brush border. Severe or bloody diarrhea was absent in these patients. These data suggest that ED feeding provides prophylaxis against the acute phase of radiation injury in patients undergoing high-dose, short-course radiotherapy for invasive bladder cancer and that it is a safe and feasible means of postoperative nutritional support, even in the presence of a fresh bowel anastomosis

  20. Combination downflow-upflow vapor-liquid separator

    Energy Technology Data Exchange (ETDEWEB)

    Kidwell, John H. (Uniontown, OH); Prueter, William P. (Alliance, OH); Eaton, Andrew M. (Alliance, OH)

    1987-03-10

    An improved vapor-liquid separator having a vertically disposed conduit for flow of a mixture. A first, second and third plurality of curved arms penetrate and extend within the conduit. A cylindrical member is radially spaced from the conduit forming an annulus therewith and having perforations and a retaining lip at its upper end.

  1. 49 CFR 393.77 - Heaters.

    Science.gov (United States)

    2010-10-01

    ... or of any exposed portions of the heaters, inclusive of exhaust stacks, pipes, or conduits shall be... disassembly of any of its parts, including exhaust stacks, pipes, or conduits, upon overturn of the vehicle in... will never exceed 0.2 percent in the cargo space. The exhaust pipe, stack, or conduit if required shall...

  2. Auto-positioning ultrasonic transducer system

    Science.gov (United States)

    Buchanan, Randy K. (Inventor)

    2010-01-01

    An ultrasonic transducer apparatus and process for determining the optimal transducer position for flow measurement along a conduit outer surface. The apparatus includes a transmitting transducer for transmitting an ultrasonic signal, said transducer affixed to a conduit outer surface; a guide rail attached to a receiving transducer for guiding movement of a receiving transducer along the conduit outer surface, wherein the receiving transducer receives an ultrasonic signal from the transmitting transducer and sends a signal to a data acquisition system; and a motor for moving the receiving transducer along the guide rail, wherein the motor is controlled by a controller. The method includes affixing a transmitting transducer to an outer surface of a conduit; moving a receiving transducer on the conduit outer surface, wherein the receiving transducer is moved along a guide rail by a motor; transmitting an ultrasonic signal from the transmitting transducer that is received by the receiving transducer; communicating the signal received by the receiving transducer to a data acquisition and control system; and repeating the moving, transmitting, and communicating along a length of the conduit.

  3. Combination downflow-upflow vapor-liquid separator

    Energy Technology Data Exchange (ETDEWEB)

    Kidwell, J.H.; Prueter, W.P.; Eaton, A.M.

    1987-03-10

    An improved vapor-liquid separator is described having a vertically disposed conduit for flow of a mixture. A first, second and third plurality of curved arms penetrate and extend within the conduit. A cylindrical member is radially spaced from the conduit forming an annulus therewith and having perforations and a retaining lip at its upper end. 11 figs.

  4. Murray's law, the "Yarrum'" optimum, and the hydraulic architecture of compound leaves

    Science.gov (United States)

    Katherine A. McCulloh; John S. Sperry; Frederick C. Meinzer; Barbara Lachenbruch; Cristian. Atala

    2009-01-01

    There are two optima for maximizing hydraulic conductance per vasculature volume in plants. Murray's law (ML) predicts the optimal conduit taper for a fixed change in conduit number across branch ranks. The opposite, the Yarrum optimum (YO), predicts the optimal change in conduit number for a fixed taper. We derived the solution for YO and then evaluated...

  5. Percutaneous transhepatic obliteration of stomal variceal hemorrhage from an ileal conduct: Case report and brief literature review

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seung Hyun; Lee, Shin Jae; Won, Jong Yun; Park, Sung Il; Lee, Do Yun; Kim, Man Deuk [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Do Young [Institute of Gastroenterology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-11-15

    Variceal bleeding is an unusual complication of ileal conduits. We report a case in which recurrent stomal variceal hemorrhage from an ileal conduit for bladder cancer was successfully treated by percutaneous transhepatic obliteration (PTO) using microcoils and N-butyl cyanoacrylate. Therefore, PTO can be one treatment option to prevent recurrent stomal variceal bleeding from ileal conduits.

  6. 医用OB胶联合几丁聚糖-胶原导管修复兔面神经损伤的实验研究%Facial nerve repair with OB glue and chitosan-collagen conduit:An experimental study in rabbits

    Institute of Scientific and Technical Information of China (English)

    屈振宇; 曲卫国; 马卫东; 曲晓娟; 张璐; 裘罡

    2011-01-01

    PORFUSE: To explore the effect of using OB glue combined with chitosan-collagen conduit to repair rabbit facial nerve injury. METHODS: Thirty Chinese rabbits were divided into 3 groups randomly. The injury in right facial nerve of rabbits was repaired using: nerve autografts (group I ), OB glue (group Ⅱ), and OB glue with chitosan-collagen conduit (group Ⅲ) in 3 groups,respectively. Gross observation, electrophysiological study, histological study and image analysis were performed 16 weeks postoperatively .The data was subjected to one-way ANOVA with SPSS 17.0 software package to evaluate nerve regeneration. RESULTS: Nerve regeneration was obvious observed 16 weeks postoperatively and could resist certain tension . Chitosan-collagen conduit was degraded 16 weeks postoperatively and restrained the formation of neuroma. The tissue adhesions in group I and group Ⅱ was more severe than in group Ⅲ. The recovery of neuro-muscular function was good in 3 groups,and motor nerve action potential was not significantly different among 3 groups (P>0.05),but the compound muscle action potential (CMAP) of regenerated nerve was significantly higher in group Ⅲ than in group Ⅱ (P0.05).Different degree of hyperplasia of fibrous connective tissue and new formed capillaries was noted ,nrnl inflammatory cell infiltration was also found in 3 groups. The effect of chitosan - collagen ennduil in group Ⅲ was observed both under low magnification of microscope and high nullification with Gomori's silver staining.The recovery rale of myelinated fibrr cross section diameler in 3 groups was different (p0.05 ). CONCLUSION: Chitnsan-collagRn conduit has excellent biocompatibilty. It can be OB glue to repair nerves injuries with good results. Supported by Dalian Outstanding Science and Technology Talents Fund (2006J23JH016).%目的:探讨医用OB胶联合几丁聚糖--胶原导管修复兔面神经损伤的效果.方法:30只健康中国大耳白兔随机分为3

  7. Retort for distilling oil from shales and other fuels

    Energy Technology Data Exchange (ETDEWEB)

    Wood, E C

    1931-04-17

    A retort is constructed in the form of a flat shallow covered conduit through which the fuel in a pulverized form is continuously conveyed on a train of pans so loaded as to completely fill the conduit, heat being applied to an adequate central portion of the conduit to effect the distillation of the fuel. The roof or cover is sufficiently higher for the extent of such heated portion to afford space for and thereby facilitate the offtake of the distillation products while the ends of the conduit remain sealed against the escape of such products.

  8. Unbundled infrastructure firms: Competition and continuing regulation

    Science.gov (United States)

    Hogendorn, Christiaan Paul

    Unbundled infrastructure firms provide conduits for electricity transmission, residential communications, etc. but are vertically disintegrated from "content" functions such as electricity generation or world-wide-web pages. These conduits are being deregulated, and this dissertation examines whether the deregulated conduits will behave in an efficient and competitive manner. The dissertation presents three essays, each of which develops a theoretical model of the behavior of conduit firms in a market environment. The first essay considers the prospects for competition between multiple conduits in the emerging market for broadband (high-speed) residential Internet access. It finds that such competition is likely to emerge as demand for these services increase. The second essay shows how a monopoly electricity or natural gas transmission conduit can facilitate collusion between suppliers of the good. It shows that this is an inefficient effect of standard price-cap regulation. The third essay considers the supply chain of residential Internet access and evaluates proposed "open access" regulation that would allow more than one firm to serve customers over the same physical infrastructure. It shows that the amount of content available to consumers does not necessarily increase under open access.

  9. Passive filtration of air egressing from nuclear containment

    Energy Technology Data Exchange (ETDEWEB)

    Malloy, III, John D

    2017-09-26

    A nuclear reactor includes a reactor core comprising fissile material disposed in a reactor pressure vessel. A radiological containment contains the nuclear reactor. A containment compartment contains the radiological containment. A heat sink includes a chimney configured to develop an upward-flowing draft in response to heated fluid flowing into a lower portion of the chimney. A fluid conduit is arranged to receive fluid from the containment compartment and to discharge into the chimney. A filter may be provided, with the fluid conduit including a first fluid conduit arranged to receive fluid from the containment compartment and to discharge into an inlet of the filter, and a second fluid conduit arranged to receive fluid from an outlet of the filter and to discharge into the chimney. As the draft is developed passively, there is no need for a blower or pump configured to move fluid through the fluid conduit.

  10. Extended fuel cycle operation for pressurized water reactor plants

    International Nuclear Information System (INIS)

    Silvestri, G.J. Jr.

    1978-01-01

    A nuclear steam turbine power plant system having an arrangement therein for extended fuel cycle operation is described. The power plant includes a turbine connected at its inlet to a source of motive fluid having a predetermined pressure associated therewith. The turbine has also connected thereto an extraction conduit which extracts steam from a predetermined location therein for use in an associated apparatus. A bypass conduit is provided between a point upstream of the inlet and the extraction conduit. A flow control device is provided within the bypass conduit and opens when the pressure of the motive steam supply drops beneath the predetermined pressure as a result of reactivity loss within the nuclear reactor. Opening of the bypass conduit provides flow to the associated apparatus and at the same time provides an increased flow orifice to maintain fluid flow rate at a predetermined level

  11. Superconducting magnet cooling system

    Science.gov (United States)

    Vander Arend, Peter C.; Fowler, William B.

    1977-01-01

    A device is provided for cooling a conductor to the superconducting state. The conductor is positioned within an inner conduit through which is flowing a supercooled liquid coolant in physical contact with the conductor. The inner conduit is positioned within an outer conduit so that an annular open space is formed therebetween. Through the annular space is flowing coolant in the boiling liquid state. Heat generated by the conductor is transferred by convection within the supercooled liquid coolant to the inner wall of the inner conduit and then is removed by the boiling liquid coolant, making the heat removal from the conductor relatively independent of conductor length.

  12. Composition-structure-property (Zn2+ and Ca2+ ion release) evaluation of Si-Na-Ca-Zn-Ce glasses: Potential components for nerve guidance conduits

    International Nuclear Information System (INIS)

    Zhang, X.F.; Kehoe, S.; Adhi, S.K.; Ajithkumar, T.G.; Moane, S.; O'Shea, H.; Boyd, D.

    2011-01-01

    Bioactive glasses have demonstrated tailored therapeutic ion release, primarily with respect to the augmentation of hard tissues. However, controlled degradation and release of therapeutic ions from biomaterials may also play an important role in soft tissue regeneration such as repair of peripheral nerve discontinuities. In this study, three silica based glasses (0.5SiO 2 -0.2CaO-0.13ZnO-XNa 2 O-(0.17-X) CeO 2 ) where, (0.04 29 Si isotope was probed for each glass using 29 Si MAS-NMR, whilst the thermal characteristics of each glass were examined using DTA. Following these analyses, ion release profiles for Ca 2+ and Zn 2+ were evaluated; an equivalent specific surface area of 1 m 2 of each glass powder was incubated (37 deg. C) in 10 ml of citric acid buffer and TRIS-HCI buffer solution (pH 3.0 and pH 7.4 respectively) for incubation periods of up to 30 days. The Zn 2+ concentration of each filtrate was analysed using flame Atomic Absorption Spectroscopy (Varian AA240FS Fast Sequential AAS) and the Ca 2+ concentration of each filtrate was determined using Inductively Coupled Plasma-Mass Spectrometer (Varian 820 ICP-MS). Results obtained from the 29 Si MAS-NMR spectra indicated Q 2 structures pervading the network. An analytical model was proposed to analyse the ion release profiles for each glass, and indicated heterogeneous dissolution of glass networks. The ion release data demonstrates that ion release in the range (19.26-3130 ppm) for Ca 2+ and in the range (5.97-4904 ppm) for Zn 2+ occurred. Release of such elements, at appropriate levels, from peripheral nerve guidance conduits may be advantageous with respect to the repair of peripheral nerve discontinuities.

  13. Water displacement mercury pump

    Science.gov (United States)

    Nielsen, M.G.

    1984-04-20

    A water displacement mercury pump has a fluid inlet conduit and diffuser, a valve, a pressure cannister, and a fluid outlet conduit. The valve has a valve head which seats in an opening in the cannister. The entire assembly is readily insertable into a process vessel which produces mercury as a product. As the mercury settles, it flows into the opening in the cannister displacing lighter material. When the valve is in a closed position, the pressure cannister is sealed except for the fluid inlet conduit and the fluid outlet conduit. Introduction of a lighter fluid into the cannister will act to displace a heavier fluid from the cannister via the fluid outlet conduit. The entire pump assembly penetrates only a top wall of the process vessel, and not the sides or the bottom wall of the process vessel. This insures a leak-proof environment and is especially suitable for processing of hazardous materials.

  14. Shape memory polymer medical device

    Science.gov (United States)

    Maitland, Duncan [Pleasant Hill, CA; Benett, William J [Livermore, CA; Bearinger, Jane P [Livermore, CA; Wilson, Thomas S [San Leandro, CA; Small, IV, Ward; Schumann, Daniel L [Concord, CA; Jensen, Wayne A [Livermore, CA; Ortega, Jason M [Pacifica, CA; Marion, III, John E.; Loge, Jeffrey M [Stockton, CA

    2010-06-29

    A system for removing matter from a conduit. The system includes the steps of passing a transport vehicle and a shape memory polymer material through the conduit, transmitting energy to the shape memory polymer material for moving the shape memory polymer material from a first shape to a second and different shape, and withdrawing the transport vehicle and the shape memory polymer material through the conduit carrying the matter.

  15. Contribution to the study of turbulent flow in cylindrical tubing with porous walls; Contribution a l'etude de l'ecoulement turbulent dans une conduite cylindrique a paroi poreuse

    Energy Technology Data Exchange (ETDEWEB)

    Burnage, H

    1962-07-01

    A theoretical study has been made of a fully developed turbulent flow in cylindrical tubing of circular cross-section subjected to a uniform suction through the walls. This study has made it possible to find a relationship giving the friction coefficient at the wall in terms of the amount of local suction and of the longitudinal static pressure gradient. A method for calculating the Reynolds tensions from the pressure measurements has been devised. An experimental system has been developed. Pressure measurements have been made. By using experimental results it has been possible to obtain a semi empirical expression for the friction coefficient at the wall, in terms of the amount of suction of the inlet Reynolds number, and of the abscissa. (author) [French] Une etude theorique de refoulement turbulent pleinement developpe dans une conduite cylindrique de section circulaire soumise a une aspiration parietale uniforme a ete entreprise. Elle a permis de trouver une relation donnant le coefficient de frottement a la paroi en fonction du taux d'aspiration local et du gradient de pression statique longitudinal. Une methode de calcul des tensions de Reynolds a partir des mesures de pression a ete etablie. Un dispositif experimental a ete realise et mis au point. Des mesures de pression ont ete effectuees. L'utilisation des resultats experimentaux a permis d'obtenir une expression semi-empirique du coefficient de frottement a la paroi en fonction du taux d'aspiration, du nombre de Reynolds d'entree et de l'abscisse. (auteur)

  16. Early urinary diversion with ileal conduit and vesicovaginostomy in the treatment of radiation cystitis due to carcinoma cervix: a study from a tertiary care hospital in South India.

    Science.gov (United States)

    Banerji, John Samuel; Devasia, Antony; Kekre, Nitin Sudhakar; Chacko, Ninan

    2015-10-01

    To study the magnitude of radiation cystitis following radiation therapy for carcinoma cervix, and propose an algorithm to decide on early diversion, with or without vesicovaginostomy. Women who developed radiation cystitis following radiotherapy for carcinoma cervix from January 1998 to December 2011 were included in this retrospective study. Electronic hospital records were analysed to document the presence of radiation cystitis. All women who developed evidence of radiation-induced cystitis, according to the common toxicity and Radiation Therapy Oncology Group criteria, were included in the study. We looked at transfusion requirements, number of hospital admissions, quality of life and cost involved. Chi-square tests were done where applicable. SPSS version 16 was used for analysis. Of the 902 patients who received radiation for carcinoma cervix in the 13-year period, 62 (6.87%) developed grade 3/4 cystitis. Twenty-eight of them underwent ileal conduit diversion, with 18 undergoing concomitant vesicovaginostomy. When compared with the patients who did not have diversion, the transfusion requirements, number of hospital admissions and quality of life had a statistically significant difference. Cost analysis of early diversion too showed a marginal benefit with early diversion. The limitation of the study was that it was retrospective in nature. In radiation cystitis, multiple hospital admissions and consequential increase in cost is the norm. In severe disease, early diversion is a prudent, cost-effective approach with good quality of life and early return to normal activity. © 2014 Royal Australasian College of Surgeons.

  17. Adjustable extender for instrument module

    International Nuclear Information System (INIS)

    Sevec, J.B.; Stein, A.D.

    1975-01-01

    A blank extender module used to mount an instrument module in front of its console for repair or test purposes has been equipped with a rotatable mount and means for locking the mount at various angles of rotation for easy accessibility. The rotatable mount includes a horizontal conduit supported by bearings within the blank module. The conduit is spring-biased in a retracted position within the blank module and in this position a small gear mounted on the conduit periphery is locked by a fixed pawl. The conduit and instrument mount can be pulled into an extended position with the gear clearing the pawl to permit rotation and adjustment of the instrument

  18. Hypoglossal-facial anastomosis (HFA) over a 10 mm gap bridged by a Y-tube-conduit enhances neurite regrowth and reduces collateral axonal branching at the lesion site.

    Science.gov (United States)

    Ozsoy, Umut; Demirel, Bahadir Murat; Hizay, Arzu; Ozsoy, Ozlem; Ankerne, Janina; Angelova, Srebrina; Sarikcioglu, Levent; Ucar, Yasar; Angelov, Doychin N

    2011-01-01

    The outcome of severe peripheral nerve injuries requiring surgical repair (transection and suture) is usually poor. Recent work suggests that direct suture of nerves increases collagen production and provides unfavourable conditions for a proper axonal regrowth. We tested whether entubulation of the hypoglossal nerve into a Y-tube conduit connecting it with the zygomatic and buccal facial nerve branches would improve axonal pathfinding at the lesion site, quality of muscle reinnervation and recovery of vibrissal whisking. For hypoglossal-facial anastomosis (HFA) over a Y-tube (HFA-Y-tube) the proximal stump of the hypoglossal nerve was entubulated and sutured into the long arm of a Y-tube (isogeneic abdominal aorta with its bifurcation). The zygomatic and buccal facial branches were entubulated and sutured to the short arms of the Y-tube. Restoration of vibrissal motor performance, degree of collateral axonal branching at the lesion site and quality of neuro-muscular junction (NMJ) reinnervation were compared to animals receiving HFA-Coaptation (no entubulation) after 4 months. HFA-Y-tube reduced collateral axonal branching. However it failed to reduce the proportion of polyinnervated NMJ and did not improve functional outcome when compared to HFA-Coaptation. Elimination of compression by tightly opposed nerve fragments improved axonal pathfinding. However, biometric analysis of vibrissae movements did not show positive effects suggesting that polyneuronal reinnervation - rather than collateral branching - may be the critical limiting factor. Since polyinnervation of muscle fibers is activity-dependent and can be manipulated, the present findings raise hopes that clinically feasible and effective therapies after HFA could be soon designed and tested.

  19. Evaluation of upward migration around a deep injection well

    International Nuclear Information System (INIS)

    Chia, Yeeping; Chiu, J.

    1994-01-01

    The long-term containment of injected wastes in the deep subsurface is expected to be achieved under suitable geologic and hydrologic conditions and by the use of competent engineering practices. Field experiences, however, indicate that waste containment may be affected by hydrologic conduits around the injection well. To assess the potential effects of these conduits, upward migration of injected waste is examined through the use of numerical models under various conditions. Test results indicate that without any preferential hydrologic conduits, most of the injected waste moves laterally in the injection interval, whereas only a small amount of waste migrates upward into the containment interval. When vertical fractures in the disturbed zone or defects in the cement seal around the wellbore exist, the contaminant can move rapidly upward along these conduits to an overlying aquifer, from which it migrates in the lateral direction. The contamination of the overlying aquifer that results from the upward migration of injected waste through these conduits cannot be impeded by a thick, low-permeability containment interval. However, when permeable interbeds exist within the containment interval, a significant portion of the waste migrating upward can be diverted laterally before reaching the overlying aquifer. The front of built-up pressure can reach the aquifer or permeable interbed immediately overlying the injection interval through the preferential hydrologic conduits shortly after the injection starts, but it cannot move farther upward because of pressure dissipation in the permeable formation. This study suggests that the injected waste has the potential to migrate upward into overlying formations through preferential migration conduits around the wellbore

  20. Neural stem cells promote nerve regeneration through IL12-induced Schwann cell differentiation.

    Science.gov (United States)

    Lee, Don-Ching; Chen, Jong-Hang; Hsu, Tai-Yu; Chang, Li-Hsun; Chang, Hsu; Chi, Ya-Hui; Chiu, Ing-Ming

    2017-03-01

    Regeneration of injured peripheral nerves is a slow, complicated process that could be improved by implantation of neural stem cells (NSCs) or nerve conduit. Implantation of NSCs along with conduits promotes the regeneration of damaged nerve, likely because (i) conduit supports and guides axonal growth from one nerve stump to the other, while preventing fibrous tissue ingrowth and retaining neurotrophic factors; and (ii) implanted NSCs differentiate into Schwann cells and maintain a growth factor enriched microenvironment, which promotes nerve regeneration. In this study, we identified IL12p80 (homodimer of IL12p40) in the cell extracts of implanted nerve conduit combined with NSCs by using protein antibody array and Western blotting. Levels of IL12p80 in these conduits are 1.6-fold higher than those in conduits without NSCs. In the sciatic nerve injury mouse model, implantation of NSCs combined with nerve conduit and IL12p80 improves motor recovery and increases the diameter up to 4.5-fold, at the medial site of the regenerated nerve. In vitro study further revealed that IL12p80 stimulates the Schwann cell differentiation of mouse NSCs through the phosphorylation of signal transducer and activator of transcription 3 (Stat3). These results suggest that IL12p80 can trigger Schwann cell differentiation of mouse NSCs through Stat3 phosphorylation and enhance the functional recovery and the diameter of regenerated nerves in a mouse sciatic nerve injury model. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Horizontal rotation of the local stress field in response to magmatic activity: Evidence from case studies and modeling

    Science.gov (United States)

    Roman, D. C.

    2003-12-01

    A complete understanding of the initiation, evolution, and termination of volcanic eruptions requires reliable monitoring techniques to detect changes in the conduit system during periods of activity, as well as corresponding knowledge of conduit structure and of magma physical properties. Case studies of stress field orientation prior to, during, and after magmatic activity can be used to relate changes in stress field orientation to the state of the magmatic conduit system. These relationships may be tested through modeling of induced stresses. Here I present evidence from case studies and modeling that horizontal rotation of the axis of maximum compressive stress at an active volcano indicates pressurization of a magmatic conduit, and that this rotation, when observed, may also be indicative of the physical properties of the ascending magma. Changes in the local stress field orientation during the 1992 eruption sequence at Crater Peak (Mt. Spurr), Alaska were analyzed by calculating and inverting subsets of over 150 fault-plane solutions. Local stress tensors for four time periods, corresponding approximately to changes in activity at the volcano, were calculated based on the misfit of individual fault-plane solutions to a regional stress tensor. Results indicate that for nine months prior to the eruption, local maximum compressive stress was oriented perpendicular to regional maximum compressive stress. A similar horizontal rotation was observed beginning in November of 1992, coincident with an episode of elevated earthquake and tremor activity indicating intrusion of magma into the conduit. During periods of quiescence the local stress field was similar to the regional stress field. Similar horizontal rotations have been observed at Mt. Ruapehu, New Zealand (Miller and Savage 2001, Gerst 2003), Usu Volcano, Japan (Fukuyama et al. 2001), Unzen Volcano, Japan (Umakoshi et al. 2001), and Mt. St. Helens Volcano, USA (Moran 1994) in conjunction with eruptive

  2. Detection of contamination of municipal water distribution systems

    Science.gov (United States)

    Cooper, John F [Oakland, CA

    2012-01-17

    A system for the detection of contaminates of a fluid in a conduit. The conduit is part of a fluid distribution system. A chemical or biological sensor array is connected to the conduit. The sensor array produces an acoustic signal burst in the fluid upon detection of contaminates in the fluid. A supervisory control system connected to the fluid and operatively connected to the fluid distribution system signals the fluid distribution system upon detection of contaminates in the fluid.

  3. Biological detector and method

    Science.gov (United States)

    Sillerud, Laurel; Alam, Todd M; McDowell, Andrew F

    2013-02-26

    A biological detector includes a conduit for receiving a fluid containing one or more magnetic nanoparticle-labeled, biological objects to be detected and one or more permanent magnets or electromagnet for establishing a low magnetic field in which the conduit is disposed. A microcoil is disposed proximate the conduit for energization at a frequency that permits detection by NMR spectroscopy of whether the one or more magnetically-labeled biological objects is/are present in the fluid.

  4. Power generation systems and methods

    Science.gov (United States)

    Jones, Jack A. (Inventor); Chao, Yi (Inventor)

    2011-01-01

    A power generation system includes a plurality of submerged mechanical devices. Each device includes a pump that can be powered, in operation, by mechanical energy to output a pressurized output liquid flow in a conduit. Main output conduits are connected with the device conduits to combine pressurized output flows output from the submerged mechanical devices into a lower number of pressurized flows. These flows are delivered to a location remote of the submerged mechanical devices for power generation.

  5. 'Being a conduit' between hospital and home: stakeholders' views and perceptions of a nurse-led Palliative Care Discharge Facilitator Service in an acute hospital setting.

    Science.gov (United States)

    Venkatasalu, Munikumar Ramasamy; Clarke, Amanda; Atkinson, Joanne

    2015-06-01

    To explore and critically examine stakeholders' views and perceptions concerning the nurse-led Palliative Care Discharge Service in an acute hospital setting and to inform sustainability, service development and future service configuration. The drive in policy and practice is to enable individuals to achieve their preferred place of care during their last days of life. However, most people in UK die in acute hospital settings against their wishes. To facilitate individuals' preferred place of care, a large acute hospital in northeast England implemented a pilot project to establish a nurse-led Macmillan Palliative Care Discharge Facilitator Service. A pluralistic evaluation design using qualitative methods was used to seek stakeholders' views and perceptions of this service. In total, 12 participants (five bereaved carers and seven health professionals) participated in the evaluation. Semi-structured interviews were conducted with bereaved carers who used this service for their relatives. A focus group and an individual interview were undertaken with health professionals who had used the service since its inception. Individual interviews were also conducted with the Discharge Facilitator and service manager. Analysis of all data was guided by Framework Analysis. Four key themes emerged relating to the role of the Discharge Facilitator Service: achieving preferred place of care; the Discharge Facilitator as the 'conduit' between hospital and community settings; delays in hospital discharge and stakeholders' perceptions of the way forward for the service. The Discharge Facilitator Service acted as a reliable resource and support for facilitating the fast-tracking of end-of-life patients to their preferred place of care. Future planning for hospital-based palliative care discharge facilitating services need to consider incorporating strategies that include: increased profile of the service, expansion of service provision and the Discharge Facilitator's earlier

  6. A Meta-Analysis of Outcomes After In Situ Reconstructions for Aortic Graft Infection.

    Science.gov (United States)

    Batt, Michel; Feugier, Patrick; Camou, Fabrice; Coffy, Amandine; Senneville, Eric; Caillon, Jocelyne; Calvet, Brigitte; Chidiac, Christian; Laurent, Frederic; Revest, Matthieu; Daures, Jean Pierre

    2018-05-01

    To confirm the advantage of in situ reconstruction (ISR) over extra-anatomic reconstruction (EAR) for aortic graft infection and determine the most appropriate conduit including autogenous veins, cryopreserved allografts, and synthetic prosthesis (standard, rifampicin of silver polyesters). A meta-analysis was conducted with rate of mortality, graft occlusion, amputation, and reinfection. A meta-regression was performed with 4 factors: patients' age, presence of prosthetic-duodenal fistula (PDF), virulent organisms, or nonvirulent organisms. In situ reconstruction over EAR seems to favor all events. For the 5 conduits used for ISR, according to operative mortality, age of the patients looks to have a positive correlation only for silver polyester and no conduit present any advantage in the presence of PDF. Reinfection seems to be not significantly different for the 5 conduits, and only autogenous veins appear to have a positive correlation with infecting organisms. In situ reconstruction may be considered as first-line treatment. Our results suggest that silver polyesters appear to be most appropriate for older patients, and in order to limit reinfection, autogenous veins are probably the most suitable conduit.

  7. Cooling system for superconducting magnet

    Science.gov (United States)

    Gamble, Bruce B.; Sidi-Yekhlef, Ahmed

    1998-01-01

    A cooling system is configured to control the flow of a refrigerant by controlling the rate at which the refrigerant is heated, thereby providing an efficient and reliable approach to cooling a load (e.g., magnets, rotors). The cooling system includes a conduit circuit connected to the load and within which a refrigerant circulates; a heat exchanger, connected within the conduit circuit and disposed remotely from the load; a first and a second reservoir, each connected within the conduit, each holding at least a portion of the refrigerant; a heater configured to independently heat the first and second reservoirs. In a first mode, the heater heats the first reservoir, thereby causing the refrigerant to flow from the first reservoir through the load and heat exchanger, via the conduit circuit and into the second reservoir. In a second mode, the heater heats the second reservoir to cause the refrigerant to flow from the second reservoir through the load and heat exchanger via the conduit circuit and into the first reservoir.

  8. Contacting particulate solids with liquids

    International Nuclear Information System (INIS)

    Hodgson, T.D.

    1980-01-01

    Apparatus is described for contacting particulate solids with a fluid. The particular applications described are 1) an acid dissolver for dissolving plutonium from plutonium contaminated ash produced by the incineration of waste such as rubber gloves, tissue paper etc. and 2) apparatus for dissolving gel spheres of nuclear fuel material. The liquid, e.g. acid for use in a leaching process flows through a vertical conduit and past a series of baffles spaced along the axis of the conduit. Each baffle defines a mixing chamber and provides a small gap around its perimeter between the baffle and the wall of the conduit. The baffles are provided with sloping top surfaces for preventing solid particles from settling on the baffles and sloping undersurfaces to improve mixing of the liquid and the solid particles. The liquid flows upwards in the conduit but solid particles may be fed from the top or from the bottom of the conduit to mix with the liquid. Gas may be introduced to promote improved flow conditions. (U.K.)

  9. In Vivo Evaluation of Short-Term Performance of New Three-Layer Collagen-Based Vascular Graft Designed for Low-Flow Peripheral Vascular Reconstructions

    Directory of Open Access Journals (Sweden)

    Tomas Grus

    2018-01-01

    Full Text Available Aim. The aim of this study was to evaluate short-term patency of the new prosthetic graft and its structural changes after explantation. Methods. The study team developed a three-layer conduit composed of a scaffold made from polyester coated with collagen from the inner and outer side with an internal diameter of 6 mm. The conduit was implanted as a bilateral bypass to the carotid artery in 7 sheep and stenosis was created in selected animals. After a period of 161 days, the explants were evaluated as gross and microscopic specimens. Results. The initial flow rate (median ± IQR in grafts with and without artificial stenosis was 120±79 ml/min and 255±255 ml/min, respectively. Graft occlusion occurred after 99 days in one of 13 conduits (patency rate: 92%. Wall-adherent thrombi occurred only in sharp curvatures in two grafts. Microscopic evaluation showed good engraftment and preserved structure in seven conduits; inflammatory changes with foci of bleeding, necrosis, and disintegration in four conduits; and narrowing of the graft due to thickening of the wall with multifocal separation of the outer layer in two conduits. Conclusions. This study demonstrates good short-term patency rates of a newly designed three-layer vascular graft even in low-flow conditions in a sheep model.

  10. Fracture mechanics behavior of a Ni-Fe superalloy sheath for superconducting fusion magnets. Pt. 1. Property measurements

    International Nuclear Information System (INIS)

    Tobler, R.L.; Hwang, I.S.; Steeves, M.M.

    1997-01-01

    For pt.2 see ibid., p.269-79 (1997). A seamless extruded conduit for superconductor cabling was fabricated and subjected to mechanical tests. The conduit is made of a nickel-iron alloy having aging and thermal contraction characteristics comparable with Nb 3 Sn conductors. The conduit in liquid helium at 4 K retains its ductility and offers high strength, toughness, and fatigue resistance. Specimens with surface cracks in tension offer substantial fracture resistance for the practical case of crack propagation in the through-wall direction. Fatigue tests indicate that surface cracks adopt a nearly semicircular shape as they grow through the conduit wall (L-S orientation) at rates in the power-law region that are no faster than rates in the transverse direction (L-T orientation). The serviceability of this material is discussed. (orig.)

  11. Metallographic autopsies of full-scale ITER prototype cable-in-conduit conductors after full testing in SULTAN: 1. The mechanical role of copper strands in a CICC

    International Nuclear Information System (INIS)

    Sanabria, Carlos; Lee, Peter J; Starch, William; Blum, Timothy; Larbalestier, David C; Devred, Arnaud; Jewell, Matthew C; Pong, Ian; Martovetsky, Nicolai

    2015-01-01

    Cables made with Nb 3 Sn-based superconductor strands will provide the 13 T maximum peak magnetic field of the ITER central solenoid (CS) coils and they must survive up to 60 000 electromagnetic cycles. Accordingly, prototype designs of CS cable-in-conduit-conductors (CICC) were electromagnetically tested over multiple magnetic field cycles and warm-up-cool-down scenarios in the SULTAN facility at CRPP. We report here a post-mortem metallographic analysis of two CS CICC prototypes which exhibited some rate of irreversible performance degradation during cycling. The standard ITER CS CICC cable design uses a combination of superconducting and Cu strands, and because the Lorentz force on the strand is proportional to the transport current in the strand, removing the copper strands (while increasing the Cu:SC ratio of the superconducting strands) was proposed as one way of reducing the strand load. In this study we compare the two alternative CICCs, with and without Cu strands, keeping in mind that the degradation after the SULTAN test was lower for the CICC without Cu strands. The post-mortem metallographic evaluation revealed that the overall strand transverse movement was 20% lower in the CICC without Cu strands and that the tensile filament fractures found were less, both indications of an overall reduction in high tensile strain regions. It was interesting to see that the Cu strands in the mixed cable design (with higher degradation) helped reduce the contact stresses on the high pressure side of the CICC, but in either case, the strain reduction mechanisms were not enough to suppress cyclic degradation. Advantages and disadvantages of each conductor design are discussed here aimed to understand the sources of the degradation. (paper)

  12. Influence of initial heterogeneities and recharge limitations on the evolution of aperture distributions in carbonate aquifers

    Directory of Open Access Journals (Sweden)

    B. Hubinger

    2011-12-01

    Full Text Available Karst aquifers evolve where the dissolution of soluble rocks causes the enlargement of discrete pathways along fractures or bedding planes, thus creating highly conductive solution conduits. To identify general interrelations between hydrogeological conditions and the properties of the evolving conduit systems the aperture-size frequency distributions resulting from generic models of conduit evolution are analysed. For this purpose, a process-based numerical model coupling flow and rock dissolution is employed. Initial protoconduits are represented by tubes with log-normally distributed aperture sizes with a mean μ0 = 0.5 mm for the logarithm of the diameters. Apertures are spatially uncorrelated and widen up to the metre range due to dissolution by chemically aggressive waters. Several examples of conduit development are examined focussing on influences of the initial heterogeneity and the available amount of recharge. If the available recharge is sufficiently high the evolving conduits compete for flow and those with large apertures and high hydraulic gradients attract more and more water. As a consequence, the positive feedback between increasing flow and dissolution causes the breakthrough of a conduit pathway connecting the recharge and discharge sides of the modelling domain. Under these competitive flow conditions dynamically stable bimodal aperture distributions are found to evolve, i.e. a certain percentage of tubes continues to be enlarged while the remaining tubes stay small-sized. The percentage of strongly widened tubes is found to be independent of the breakthrough time and decreases with increasing heterogeneity of the initial apertures and decreasing amount of available water. If the competition for flow is suppressed because the availability of water is strongly limited breakthrough of a conduit pathway is inhibited and the conduit pathways widen very slowly. The resulting aperture distributions are found to be

  13. Verification of the karst flow model under laboratory controlled conditions

    Science.gov (United States)

    Gotovac, Hrvoje; Andric, Ivo; Malenica, Luka; Srzic, Veljko

    2016-04-01

    Karst aquifers are very important groundwater resources around the world as well as in coastal part of Croatia. They consist of extremely complex structure defining by slow and laminar porous medium and small fissures and usually fast turbulent conduits/karst channels. Except simple lumped hydrological models that ignore high karst heterogeneity, full hydraulic (distributive) models have been developed exclusively by conventional finite element and finite volume elements considering complete karst heterogeneity structure that improves our understanding of complex processes in karst. Groundwater flow modeling in complex karst aquifers are faced by many difficulties such as a lack of heterogeneity knowledge (especially conduits), resolution of different spatial/temporal scales, connectivity between matrix and conduits, setting of appropriate boundary conditions and many others. Particular problem of karst flow modeling is verification of distributive models under real aquifer conditions due to lack of above-mentioned information. Therefore, we will show here possibility to verify karst flow models under the laboratory controlled conditions. Special 3-D karst flow model (5.6*2.6*2 m) consists of concrete construction, rainfall platform, 74 piezometers, 2 reservoirs and other supply equipment. Model is filled by fine sand (3-D porous matrix) and drainage plastic pipes (1-D conduits). This model enables knowledge of full heterogeneity structure including position of different sand layers as well as conduits location and geometry. Moreover, we know geometry of conduits perforation that enable analysis of interaction between matrix and conduits. In addition, pressure and precipitation distribution and discharge flow rates from both phases can be measured very accurately. These possibilities are not present in real sites what this model makes much more useful for karst flow modeling. Many experiments were performed under different controlled conditions such as different

  14. Karst aquifer characterization using geophysical remote sensing of dynamic recharge events

    Science.gov (United States)

    Grapenthin, R.; Bilek, S. L.; Luhmann, A. J.

    2017-12-01

    Geophysical monitoring techniques, long used to make significant advances in a wide range of deeper Earth science disciplines, are now being employed to track surficial processes such as landslide, glacier, and river flow. Karst aquifers are another important hydrologic resource that can benefit from geophysical remote sensing, as this monitoring allows for safe, noninvasive karst conduit measurements. Conduit networks are typically poorly constrained, let alone the processes that occur within them. Geophysical monitoring can also provide a regionally integrated analysis to characterize subsurface architecture and to understand the dynamics of flow and recharge processes in karst aquifers. Geophysical signals are likely produced by several processes during recharge events in karst aquifers. For example, pressure pulses occur when water enters conduits that are full of water, and experiments suggest seismic signals result from this process. Furthermore, increasing water pressure in conduits during recharge events increases the load applied to conduit walls, which deforms the surrounding rock to yield measureable surface displacements. Measureable deformation should also occur with mass loading, with subsidence and rebound signals associated with increases and decreases of water mass stored in the aquifer, respectively. Additionally, geophysical signals will likely arise with turbulent flow and pore pressure change in the rock surrounding conduits. Here we present seismic data collected during a pilot study of controlled and natural recharge events in a karst aquifer system near Bear Spring, near Eyota, MN, USA as well as preliminary model results regarding the processes described above. In addition, we will discuss an upcoming field campaign where we will use seismometers, tiltmeters, and GPS instruments to monitor for recharge-induced responses in a FL, USA karst system with existing cave maps, coupling these geophysical observations with hydrologic and

  15. Analysis of the karst aquifer structure of the Lamalou area (Herault, France) with ground penetrating radar

    International Nuclear Information System (INIS)

    Al-Fares, W.; Bakalowicz, M.; Guerin, R.; Dukhan, M.

    2004-01-01

    The study site at Lamalou karst spring Hortus karst plateau) is situated 40 km north of Montpellier in France. It consists of a limestone plateau, drained by a karst conduit discharging as a spring. This conduit extends for a few dozen meters in fractured and karstified limestone rocks, 15 to 70 m below the surface. The conduit is accessible from the surface. The main goal of this study is to analyze the surface part of the karst and to highlight the karstic features and among them the conduit, and to test the performances of ground penetrating radar (GPR) in a karstic environment. This method thus appears particularly well adapted to the analysis of the near-surface (<30 m in depth) structure of a karst, especially when clayey coating or soil that absorbs and attenuates the radar is rare and discontinuous. A GPR pulse EKKO 100 (Sensors and Software) was used on the site with a 50 MHz antenna frequency. The results highlight structures characterizing the karstic environment: The epikarst, bedding planes, fractured and karstified zones, compact and massive rock and karrens, a typical karst landform. One of the sections revealed in detail the main conduit located at a depth of 20 m, and made it possible to determine its geometry. This site offers possibilities of validation of GPR data by giving direct access to the karstic conduit and through two cored boreholes. These direct observations confirm the interpretation of all the GPR sections. (author

  16. Allotransplanted DRG neurons or Schwann cells affect functional recovery in a rodent model of sciatic nerve injury.

    Science.gov (United States)

    Dayawansa, Samantha; Wang, Ernest W; Liu, Weimin; Markman, John D; Gelbard, Harris A; Huang, Jason H

    2014-11-01

    In this study, the functional recoveries of Sprague-Dawley rats following repair of a complete sciatic nerve transection using allotransplanted dorsal root ganglion (DRG) neurons or Schwann cells were examined using a number of outcome measures. Four groups were compared: (1) repair with a nerve guide conduit seeded with allotransplanted Schwann cells harvested from Wistar rats, (2) repair with a nerve guide conduit seeded with DRG neurons, (3) repair with solely a nerve guide conduit, and (4) sham-surgery animals where the sciatic nerve was left intact. The results corroborated our previous reported histology findings and measures of immunogenicity. The Wistar-DRG-treated group achieved the best recovery, significantly outperforming both the Wistar-Schwann group and the nerve guide conduit group in the Von Frey assay of touch response (P DRG and Wistar-Schwann seeded repairs showed lower frequency and severity in an autotomy measure of the self-mutilation of the injured leg because of neuralgia. These results suggest that in complete peripheral nerve transections, surgical repair using nerve guide conduits with allotransplanted DRG and Schwann cells may improve recovery, especially DRG neurons, which elicit less of an immune response.

  17. Releasable, high-pressure seal and method of forming same

    International Nuclear Information System (INIS)

    Holman, R.R.; Turkail, D.N.

    1980-01-01

    An inexpensive releaseable, high-pressure seal was developed, which can withstand pressures over 70 atm, and is particularly useful for nuclear reactors where remote-handling equipment must be used to access the flanged connections. It is smaller than existing high-pressure seals and does not require as many bolts. The fail-safe quality of the seal does not depend on close tolerances or high-quality surface finishes. The seal comprises two conduits through which the high-pressure fluid flows, each fitted with flanges. The second flange has a periphery attached to the second conduit. Each flange has a central opening for the fluid to flow through. The second flange is frustoconical in shape and is resilient so that a portion of it near its central opening can be resiliently biased towards the first flange. A seal ring between the end flanges seals the interior of the conduits from the exterior. A force is applied to the seal ring which acts nearly parallel to the axis of the conduits and varies as a function of the fluid pressure inside of the conduits. The flanges are attached to each other with peripheral collars via a circumferential clamp. (DN)

  18. Heat pipes to reduce engine exhaust emissions

    Science.gov (United States)

    Schultz, D. F. (Inventor)

    1984-01-01

    A fuel combustor is presented that consists of an elongated casing with an air inlet conduit portion at one end, and having an opposite exit end. An elongated heat pipe is mounted longitudinally in the casing and is offset from and extends alongside the combustion space. The heat pipe is in heat transmitting relationship with the air intake conduit for heating incoming air. A guide conduit structure is provided for conveying the heated air from the intake conduit into the combustion space. A fuel discharge nozzle is provided to inject fuel into the combustion space. A fuel conduit from a fuel supply source has a portion engaged in heat transfer relationship of the heat pipe for preheating the fuel. The downstream end of the heat pipe is in heat transfer relationship with the casing and is located adjacent to the downstream end of the combustion space. The offset position of the heat pipe relative to the combustion space minimizes the quenching effect of the heat pipe on the gaseous products of combustion, as well as reducing coking of the fuel on the heat pipe, thereby improving the efficiency of the combustor.

  19. Radiographic visualization of magma dynamics in an erupting volcano.

    Science.gov (United States)

    Tanaka, Hiroyuki K M; Kusagaya, Taro; Shinohara, Hiroshi

    2014-03-10

    Radiographic imaging of magma dynamics in a volcanic conduit provides detailed information about ascent and descent of magma, the magma flow rate, the conduit diameter and inflation and deflation of magma due to volatile expansion and release. Here we report the first radiographic observation of the ascent and descent of magma along a conduit utilizing atmospheric (cosmic ray) muons (muography) with dynamic radiographic imaging. Time sequential radiographic images show that the top of the magma column ascends right beneath the crater floor through which the eruption column was observed. In addition to the visualization of this magma inflation, we report a sequence of images that show magma descending. We further propose that the monitoring of temporal variations in the gas volume fraction of magma as well as its position in a conduit can be used to support existing eruption prediction procedures.

  20. Apparatus for atmospheric pressure pin-to-hole spark discharge and uses thereof

    Science.gov (United States)

    Dobrynin, Danil V.; Fridman, Alexander; Cho, Young I.; Fridman, Gregory; Friedman, Gennady

    2016-12-06

    Disclosed herein are atmospheric pressure pin-to-hole pulsed spark discharge devices and methods for creating plasma. The devices include a conduit for fluidically communicating a gas, a plasma, or both, therethrough, portion of the conduit capable of being connected to a gas supply, and a second portion of the conduit capable of emitting a plasma; a positive electrode comprising a sharp tip; and a ground plate electrode. Disclosed are methods for treating a skin ulcer using non-thermal plasma include flowing a gas through a cold spark discharge zone simultaneously with the creation of a pulsed spark discharge to give rise to a non-thermal plasma emitted from a conduit, the non-thermal plasma comprising NO; and contacting a skin ulcer with said non-thermal plasma for sufficient time and intensity to give rise to treatment of the skin ulcer.

  1. Method and apparatus for maintaining condensable constituents of a gas in a vapor phase during sample transport

    Science.gov (United States)

    Felix, Larry Gordon; Farthing, William Earl; Irvin, James Hodges; Snyder, Todd Robert

    2010-05-18

    A system for fluid transport at elevated temperatures having a conduit having a fluid inlet end and a fluid outlet end and at least one heating element disposed within the conduit providing direct heating of a fluid flowing through the conduit. The system is particularly suited for preventing condensable constituents of a high temperature fluid from condensing out of the fluid prior to analysis of the fluid. In addition, operation of the system so as to prevent the condensable constituents from condensing out of the fluid surprisingly does not alter the composition of the fluid.

  2. Heat exchanger with oscillating flow

    Science.gov (United States)

    Scotti, Stephen J. (Inventor); Blosser, Max L. (Inventor); Camarda, Charles J. (Inventor)

    1993-01-01

    Various heat exchange apparatuses are described in which an oscillating flow of primary coolant is used to dissipate an incident heat flux. The oscillating flow may be imparted by a reciprocating piston, a double action twin reciprocating piston, fluidic oscillators or electromagnetic pumps. The oscillating fluid flows through at least one conduit in either an open loop or a closed loop. A secondary flow of coolant may be used to flow over the outer walls of at least one conduit to remove heat transferred from the primary coolant to the walls of the conduit.

  3. Seismic stress analysis of feeder lines to LOFT primary coolant pump motors

    International Nuclear Information System (INIS)

    Kuehster, C.J.

    1978-01-01

    The conduit system in the LOFT Support Building was analyzed for seismic loading. The conduit itself plus its various supports were subjected to both horizontal and vertical forces. The results show the system loads or stresses to be within allowables

  4. The protection of photovoltaic power systems from lightning

    Science.gov (United States)

    Rogers, C. B.

    Lightning protection techniques at nine prototype photovoltaic power system sites with outputs from 18-225 kW are described. Noting that protection schemes are devised to fit isokeraunic data for specific sites, grounding is cited as a common feature for all systems. The grounds are, in separate instances, connected to junction boxes, frames of the solar cell panels, lead from the dc center, from the dc negative terminal, from the frames and equipment, at the array turntable, or from the building rebar frames. The dc power cables are protected by either metal conduit, metal conduit ground wire, direct burial, by rigid metal conduit, ground conductors, or by ground conductors at the ends of the conduit run. Costs run from 0.01-0.28$/W, with all the systems outfitted with bypass and blocking diodes. Direct stroke protection is viewed as less important than isokeraunic data.

  5. Collagen Conduit Versus Microsurgical Neurorrhaphy

    DEFF Research Database (Denmark)

    Boeckstyns, Michel; Sørensen, Allan Ibsen; Viñeta, Joaquin Fores

    2013-01-01

    To compare repair of acute lacerations of mixed sensory-motor nerves in humans using a collagen tube versus conventional repair.......To compare repair of acute lacerations of mixed sensory-motor nerves in humans using a collagen tube versus conventional repair....

  6. Cavitation Resistance in Seedless Vascular Plants: The Structure and Function of Interconduit Pit Membranes1[W][OPEN

    Science.gov (United States)

    Brodersen, Craig; Jansen, Steven; Choat, Brendan; Rico, Christopher; Pittermann, Jarmila

    2014-01-01

    Plant water transport occurs through interconnected xylem conduits that are separated by partially digested regions in the cell wall known as pit membranes. These structures have a dual function. Their porous construction facilitates water movement between conduits while limiting the spread of air that may enter the conduits and render them dysfunctional during a drought. Pit membranes have been well studied in woody plants, but very little is known about their function in more ancient lineages such as seedless vascular plants. Here, we examine the relationships between conduit air seeding, pit hydraulic resistance, and pit anatomy in 10 species of ferns (pteridophytes) and two lycophytes. Air seeding pressures ranged from 0.8 ± 0.15 MPa (mean ± sd) in the hydric fern Athyrium filix-femina to 4.9 ± 0.94 MPa in Psilotum nudum, an epiphytic species. Notably, a positive correlation was found between conduit pit area and vulnerability to air seeding, suggesting that the rare-pit hypothesis explains air seeding in early-diverging lineages much as it does in many angiosperms. Pit area resistance was variable but averaged 54.6 MPa s m−1 across all surveyed pteridophytes. End walls contributed 52% to the overall transport resistance, similar to the 56% in angiosperm vessels and 64% in conifer tracheids. Taken together, our data imply that, irrespective of phylogenetic placement, selection acted on transport efficiency in seedless vascular plants and woody plants in equal measure by compensating for shorter conduits in tracheid-bearing plants with more permeable pit membranes. PMID:24777347

  7. Assessment of key transport parameters in a karst system under different dynamic conditions based on tracer experiments: the Jeita karst system, Lebanon

    Science.gov (United States)

    Doummar, Joanna; Margane, Armin; Geyer, Tobias; Sauter, Martin

    2018-03-01

    Artificial tracer experiments were conducted in the mature karst system of Jeita (Lebanon) under various flow conditions using surface and subsurface tracer injection points, to determine the variation of transport parameters (attenuation of peak concentration, velocity, transit times, dispersivity, and proportion of immobile and mobile regions) along fast and slow flow pathways. Tracer breakthrough curves (TBCs) observed at the karst spring were interpreted using a two-region nonequilibrium approach (2RNEM) to account for the skewness in the TBCs' long tailings. The conduit test results revealed a discharge threshold in the system dynamics, beyond which the transport parameters vary significantly. The polynomial relationship between transport velocity and discharge can be related to the variation of the conduit's cross-sectional area. Longitudinal dispersivity in the conduit system is not a constant value (α = 7-10 m) and decreases linearly with increasing flow rate because of dilution effects. Additionally, the proportion of immobile regions (arising from conduit irregularities) increases with decreasing water level in the conduit system. From tracer tests with injection at the surface, longitudinal dispersivity values are found to be large (8-27 m). The tailing observed in some TBCs is generated in the unsaturated zone before the tracer actually arrives at the major subsurface conduit draining the system. This work allows the estimation and prediction of the key transport parameters in karst aquifers. It shows that these parameters vary with time and flow dynamics, and they reflect the geometry of the flow pathway and the origin of infiltrating (potentially contaminated) recharge.

  8. Does the Homograft for RVOT Reconstruction in Ross: Patients Fare Better than for Non-Ross Patients? A Single-Center Experience.

    Science.gov (United States)

    Ruzmetov, Mark; Geiss, Dale M; Shah, Jitendra J; Fortuna, Randall S; Welke, Karl F

    2015-07-01

    In patients undergoing the Ross procedure, the right ventricular outflow tract (RVOT) conduit is inserted in an orthotopic position rather than in the more heterotopic position used in the repair of complex congenital RVOT obstruction. The study aim was to compare the authors' institutional mid-term experience of large-sized homografts (>19 mm) in patients with Ross and non-Ross RVOT reconstructions. The outcome was reviewed of all homografts implanted for Ross (n = 72) or non-Ross (n = 64) RVOT reconstruction at a single center between 1993 and 2012. Echocardiographic data were reviewed to evaluate valve performance. Homograft dysfunction was defined as RVOT obstruction with peak echo-Doppler gradient >40 mmHg and/or grade >III/IV conduit valve regurgitation. Homograft failure was defined as the need for conduit replacement or catheter or surgical reintervention. The age, body weight, conduit diameter and previous surgery were significantly higher in patients with Ross compared to the non-Ross group (p = 0.002, 0.003 and Ross, n = 17; non-Ross, n = 18). The data acquired showed actuarial survival, freedom from conduit dysfunction and conduit failure to be similar in both cohorts. Freedom from any type of reoperation was worse for the Ross group (58%) than for the non-Ross group (72%) (p = 0.05). During the first 15 years after Ross or non-Ross pulmonary homograft implantation, the survival rate, freedom from failure and dysfunction, and RVOT gradient were statistically similar. Freedom from any type of reoperation was significantly higher in the non-Ross group, however.

  9. The David V Valve-Sparing Root Replacement Provides Improved Survival Compared With Mechanical Valve-conduits in the Treatment of Young Patients With Aortic Root Pathology.

    Science.gov (United States)

    Esaki, Jiro; Leshnower, Bradley G; Binongo, Jose N; Lasanajak, Yi; McPherson, LaRonica; Halkos, Michael E; Guyton, Robert A; Chen, Edward P

    2016-11-01

    Valve-sparing root replacement (VSRR) is an attractive therapy for aortic root aneurysms; however, there is a paucity of data comparing VSRR with conventional root replacement using a mechanical valve-conduit (MECH). This study evaluates and compares outcomes of VSRR and MECH. A retrospective review from 2002 to 2015 at a US academic center identified 444 patients who underwent VSRR (282 patients) or MECH (162 patients). Propensity score matching was performed, based on 22 preoperative and intraoperative characteristics, and 87 matched pairs were identified. There was no difference in mean age between the groups (VSRR 45.0 years, MECH 44.2 years, p = 0.59). The incidence of Marfan syndrome (VSRR 10.3%, MECH 12.6%, p = 0.63), type A acute aortic dissection (VSRR 25.3%, MECH 27.6%, p = 0.73), reoperation (VSRR 23.0%, MECH 21.8%, p = 0.86), and arch replacement (VSRR 54.0%, MECH 52.9%, p = 0.88) were similar in both groups. Ejection fraction was similar (VSRR 52.8% ± 10.9%, MECH 52.4% ± 11.7%, p = 0.83). Operative mortality was 2.3% with VSRR and 8.0% with MECH (p = 0.10). There were no significant differences in renal failure requiring dialysis (VSRR 1.1%, MECH 4.6%, p = 0.24), permanent neurologic dysfunction (VSRR 2.3%, MECH 6.9%, p = 0.16), and pacemaker implantation (VSRR 1.1%, MECH 1.1%, p = 0.99) between the groups. Survival at 7 years was significantly improved in patients who underwent VSSR (VSRR 85.5%, MECH 73.6%, p = 0.03). In comparison with patients undergoing MECH, there is improved midterm survival among patients undergoing VSRR, with similar operative mortality and morbidity. For appropriately selected patients, VSRR provides an attractive and potentially superior alternative to MECH. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Electrical resistivity investigation of fluvial geomorphology to evaluate potential seepage conduits to agricultural lands along the San Joaquin River, Merced County, California, 2012–13

    Science.gov (United States)

    Groover, Krishangi D.; Burgess, Matthew K.; Howle, James F.; Phillips, Steven P.

    2017-02-08

    Increased flows in the San Joaquin River, part of the San Joaquin River Restoration Program, are designed to help restore fish populations. However, increased seepage losses could result from these higher restoration flows, which could exacerbate existing drainage problems in neighboring agricultural lands and potentially damage crops. Channel deposits of abandoned river meanders that are hydraulically connected to the river could act as seepage conduits, allowing rapid and widespread water-table rise during restoration flows. There is a need to identify the geometry and properties of these channel deposits to assess their role in potential increased seepage effects and to evaluate management alternatives for reducing seepage. Electrical and electromagnetic surface geophysical methods have provided a reliable proxy for lithology in studies of fluvial and hyporheic systems where a sufficient electrical contrast exists between deposits of differing grain size. In this study, direct-current (DC) resistivity was used to measure subsurface resistivity to identify channel deposits and to map their subsurface geometry. The efficacy of this method was assessed by using DC resistivity surveys collected along a reach of the San Joaquin River in Merced County, California, during the summers of 2012 and 2013, in conjunction with borings and associated measurements from a hydraulic profiling tool. Modeled DC resistivity data corresponded with data from cores, hand-auger samples, a hydraulic profiling tool, and aerial photographs, confirming that DC resistivity is effective for differentiating between silt and sand deposits in this setting. Modeled DC resistivity data provided detailed two-dimensional cross-sectional resistivity profiles to a depth of about 20 meters. The distribution of high-resistivity units in these profiles was used as a proxy for identifying areas of high hydraulic conductivity. These data were used subsequently to guide the location and depth of wells

  11. Dual capillary tube / heat exchanger in combination with cycle priming for reducing charge migration

    Science.gov (United States)

    Gomes, Alberto Regio; Kuehl, Steven J.; Litch, Andrew D.; Wu, Guolian

    2017-07-04

    A refrigerator appliance including a multi-capacity compressor and a refrigerant circuit with two conduits and pressure reducing devices arranged in parallel between an evaporator and a condenser. Refrigerant can flow through one, both or none of the conduits and pressure reducing devices. The appliance also has a heat exchanger in contact with either one pressure reducing device, or one conduit between the pressure reducing device and the valve system. The appliance also includes a controller for priming the compressor above a nominal capacity for a predetermined or calculated duration at the beginning of an ON-cycle.

  12. Characterisation of karst hydrogeology in Western Ireland using geophysical and hydraulic modelling techniques

    Directory of Open Access Journals (Sweden)

    T. McCormack

    2017-04-01

    New hydrological insights for the region: Results suggest two primary pathways of northwards groundwater flow in the catchment, a fault which discharges offshore, and a ∼2 m diameter karst conduit running underneath the catchment lowlands against the prevailing geological dip. This conduit, whose existence was suspected but never confirmed, links a large ephemeral lake to the coast where it discharges intertidally. Hydraulic modelling indicates that the conduit network is a complex mixture of constrictions with multiple inlets and outlets. Two ephemeral lakes are shown to be hydraulically discontinuous, either drained separately or linked by a low pressure channel.

  13. Apparatus for consolidation of earth formations

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, H

    1968-02-08

    Earth formations are consolidated by injecting into the formation a fluid medium through vertically spaced perforations; a device lowered into the borehole permits creating chambers isolated from each other and communicating with only one, or a group of perforations. These chambers are connected through valved conduits to a reservoir of the consolidating medium. Each chamber or each group of chambers has its own supply conduit, and flow-measuring means are provided in each conduit. The valves may be magnetic valves, controlled electrically from the surface; the reservoirs for the consolidating medium may be equipped with hydraulically actuated pistons. (8 claims)

  14. Heat exchanger

    International Nuclear Information System (INIS)

    Drury, C.R.

    1988-01-01

    A heat exchanger having primary and secondary conduits in heat-exchanging relationship is described comprising: at least one serpentine tube having parallel sections connected by reverse bends, the serpentine tube constituting one of the conduits; a group of open-ended tubes disposed adjacent to the parallel sections, the open-ended tubes constituting the other of the conduits, and forming a continuous mass of contacting tubes extending between and surrounding the serpentine tube sections; and means securing the mass of tubes together to form a predetermined cross-section of the entirety of the mass of open-ended tubes and tube sections

  15. The parameters controlling the strength of soil-steel structures

    International Nuclear Information System (INIS)

    Barkhordari, M. A.; Abdel-Sayed, G.

    2001-01-01

    The present paper examines the ultimate load carrying capacity of soil-steel structures taking into consideration the sequence of the developments of plastic hinges, their location, and their sustained plastic moment. Non-linear analysis has been conducted using a micro-computer program in which a structural model is applied with the soil replaced by normal and tangential springs acting at the nodal points of a polygon representing the conduit wall. A comparative study has been conducted for the parameters which affect the load carrying capacity of soil-steel structure, leading to the following conclusions: (1) the load carrying capacity of the composite structure is significantly affected by the shear stiffness (or friction) of the surrounding soil; (2) the conduit span may be used when calculating the buckling load rather than the local radius of the conduit wall; (3) circular arches with sector angle of less than 180 d eg have higher load carrying capacity than equivalent re-entrant arches, i.e. arches with sector angle of more than 180 d eg; (4) the buckling load of the conduit is slightly affected by the rigidity of the lower zone of the conduit wall; (5) eccentric application of the load has practically little effect on its load carrying capacity

  16. Interactions of diffuse and focused allogenic recharge in an eogenetic karst aquifer (Florida, USA)

    Science.gov (United States)

    Langston, Abigail L.; Screaton, Elizabeth J.; Martin, Jonathan B.; Bailly-Comte, Vincent

    2012-06-01

    The karstic upper Floridan aquifer in north-central Florida (USA) is recharged by both diffuse and allogenic recharge. To understand how recharged water moves within the aquifer, water levels and specific conductivities were monitored and slug tests were conducted in wells installed in the aquifer surrounding the Santa Fe River Sink and Rise. Results indicate that diffuse recharge does not mix rapidly within the aquifer but instead flows horizontally. Stratification may be aided by the high matrix porosity of the eogenetic karst aquifer. Purging wells for sample collection perturbed conductivity for several days, reflecting mixing of the stratified water and rendering collection of representative samples difficult. Interpretive numerical simulations suggest that diffuse recharge impacts the intrusion of allogenic water from the conduit by increasing hydraulic head in the surrounding aquifer and thereby reducing influx to the aquifer from the conduit. In turn, the increase of head within the conduits affects flow paths of diffuse recharge by moving newly recharged water vertically as the water table rises and falls. This movement may result in a broad vertical zone of dissolution at the water table above the conduit system, with thinner and more focused water-table dissolution at greater distance from the conduit.

  17. Gas-Generator Augmented Expander Cycle Rocket Engine

    Science.gov (United States)

    Greene, William D. (Inventor)

    2011-01-01

    An augmented expander cycle rocket engine includes first and second turbopumps for respectively pumping fuel and oxidizer. A gas-generator receives a first portion of fuel output from the first turbopump and a first portion of oxidizer output from the second turbopump to ignite and discharge heated gas. A heat exchanger close-coupled to the gas-generator receives in a first conduit the discharged heated gas, and transfers heat to an adjacent second conduit carrying fuel exiting the cooling passages of a primary combustion chamber. Heat is transferred to the fuel passing through the cooling passages. The heated fuel enters the second conduit of the heat exchanger to absorb more heat from the first conduit, and then flows to drive a turbine of one or both of the turbopumps. The arrangement prevents the turbopumps exposure to combusted gas that could freeze in the turbomachinery and cause catastrophic failure upon attempted engine restart.

  18. Nuclear powerplant with closed gas-cooling circuit

    International Nuclear Information System (INIS)

    Haferkamp, D.; Hodzic, A.; Winter, U.

    1976-01-01

    Disclosed is a nuclear power plant comprising a pressure-tight safety vessel surrounding the entire plant, an inner vessel of reinforced concrete, a high-temperature reactor contained in the inner vessel, a gas turbine assembly having a turbine and a high- and low-pressure compressor located in a horizontally oriented chamber below the reactor, a plurality of heat exchange units positioned in a plurality of vertically oriented pods spaced radially symmetrically about the reactor and suitable conduits for carrying the reactive gas between the system components. The conduits are arranged in generally horizontally and vertically oriented straight lines, and the conduits for carrying low-pressure gas comprise a horizontal system positioned beneath the turbine assembly having a plurality of coaxial connecting tubes, collectors and distributors as well as normal conduits, so that high pressure gas flows in the internal passage and low-pressure gas flows in the outer passage. 22 claims, 7 figures

  19. Imaging the Flow Networks from a Harmonic Pumping in a Karstic Field with an Inversion Algorithm

    Science.gov (United States)

    Fischer, P.; Lecoq, N.; Jardani, A.; Jourde, H.; Wang, X.; Chedeville, S.; Cardiff, M. A.

    2017-12-01

    Identifying flow paths within karstic fields remains a complex task because of the high dependency of the hydraulic responses to the relative locations between the observation boreholes and the karstic conduits and interconnected fractures that control the main flows of the hydrosystem. In this context, harmonic pumping is a new investigation tool that permits to inform on the flow paths connectivity between the boreholes. We have shown that the amplitude and phase offset values in the periodic responses of a hydrosystem to a harmonic pumping test characterize three different type of flow behavior between the measurement boreholes and the pumping borehole: a direct connectivity response (conduit flow), an indirect connectivity (conduit and short matrix flows), and an absence of connectivity (matrix). When the hydraulic responses to study are numerous and complex, the interpretation of the flow paths requires an inverse modeling. Therefore, we have recently developed a Cellular Automata-based Deterministic Inversion (CADI) approach that permits to infer the spatial distribution of field hydraulic conductivities in a structurally constrained model. This method distributes hydraulic conductivities along linear structures (i.e. karst conduits) and iteratively modifies the structural geometry of this conduits network to progressively match the observed responses to the modeled ones. As a result, this method produces a conductivity model that is composed of a discrete conduit network embedded in the background matrix, capable of producing the same flow behavior as the investigated hydrologic system. We applied the CADI approach in order to reproduce, in a model, the amplitude and phase offset values of a set of periodic responses generated from harmonic pumping tests conducted in different boreholes at the Terrieu karstic field site (Southern France). This association of oscillatory responses with the CADI method provides an interpretation of the flow paths within the

  20. Reconstruction of a 10-mm-long median nerve gap in an ischemic environment using autologous conduits with different patterns of blood supply: A comparative study in the rat

    Science.gov (United States)

    Iria, Inês; Alves, Sara; Farinho, Ana; Pen, Cláudia; Lourenço-Silva, Nuno; Mascarenhas-Lemos, Luís; Silva-Ferreira, José; Ferraz-Oliveira, Mário; Vassilenko, Valentina; Videira, Paula Alexandra; Goyri-O’Neill, João; Pais, Diogo

    2018-01-01

    The aim of this study was to evaluate in the Wistar rat the efficacy of various autologous nerve conduits with various forms of blood supply in reconstructing a 10-mm-long gap in the median nerve (MN) under conditions of local ischemia. A 10-mm-long median nerve defect was created in the right arm. A loose silicone tube was placed around the nerve gap zone, in order to simulate a local ischemic environment. Rats were divided in the following experimental groups (each with 20 rats): the nerve Graft (NG) group, in which the excised MN segment was reattached; the conventional nerve flap (CNF) and the arterialized neurovenous flap (ANVF) groups in which the gap was bridged with homonymous median nerve flaps; the prefabricated nerve flap (PNF) group in which the gap was reconstructed with a fabricated flap created by leaving an arteriovenous fistula in contact with the sciatic nerve for 5 weeks; and the two control groups, Sham and Excision groups. In the latter group, the proximal stump of the MN nerve was ligated and no repair was performed. The rats were followed for 100 days. During this time, they did physiotherapy. Functional, electroneuromyographic and histological studies were performed. The CNF and ANVF groups presented better results than the NG group in the following assessments: grasping test, nociception, motor stimulation threshold, muscle weight, and histomorphometric evaluation. Radial deviation of the operated forepaw was more common in rats that presented worse results in the other outcome variables. Overall, CNFs and ANVFs produced a faster and more complete recovery than NGs in the reconstruction of a 10-mm-long median nerve gap in an ischemic environment in the Wistar rat. Although, results obtained with CNFs were in most cases were better than ANVFs, these differences were not statistically significant for most of the outcome variables. PMID:29659600

  1. Constraining the Magmatic System at Mount St. Helens (2004-2008) Using Bayesian Inversion With Physics-Based Models Including Gas Escape and Crystallization

    International Nuclear Information System (INIS)

    Wong, Ying-Qi; Segall, Paul; Bradley, Andrew; Anderson, Kyle

    2017-01-01

    Physics-based models of volcanic eruptions track conduit processes as functions of depth and time. When used in inversions, these models permit integration of diverse geological and geophysical data sets to constrain important parameters of magmatic systems. We develop a 1-D steady state conduit model for effusive eruptions including equilibrium crystallization and gas transport through the conduit and compare with the quasi-steady dome growth phase of Mount St. Helens in 2005. Viscosity increase resulting from pressure-dependent crystallization leads to a natural transition from viscous flow to frictional sliding on the conduit margin. Erupted mass flux depends strongly on wall rock and magma permeabilities due to their impact on magma density. Including both lateral and vertical gas transport reveals competing effects that produce nonmonotonic behavior in the mass flux when increasing magma permeability. Using this physics-based model in a Bayesian inversion, we link data sets from Mount St. Helens such as extrusion flux and earthquake depths with petrological data to estimate unknown model parameters, including magma chamber pressure and water content, magma permeability constants, conduit radius, and friction along the conduit walls. Even with this relatively simple model and limited data, we obtain improved constraints on important model parameters. We find that the magma chamber had low (<5 wt %) total volatiles and that the magma permeability scale is well constrained at ~10 –11.4 m 2 to reproduce observed dome rock porosities. Here, compared with previous results, higher magma overpressure and lower wall friction are required to compensate for increased viscous resistance while keeping extrusion rate at the observed value.

  2. Fluid flow modeling at the Lusi mud eruption, East java, Indonesia.

    Science.gov (United States)

    Collignon, Marine; Schmid, Daniel; Mazzini, Adriano

    2016-04-01

    The 29th of may 2006, gas water and mud breccia started to erupt at several localities along the Watukosek fault system, in the Sidoarjo Regency in East java, Indonesia. The most prominent eruption, named Lusi, is still active and covering a surface of nearly 7 km2, resulting in the displacement of ~ 30 000 people. Although the origin and the chemical composition of the erupted fluids have been documented, the mechanical and physical properties of the mud are poorly constrained, and many aspects still remain not understood. Very little is known about the internal dynamics of the Lusi conduit(s). In this study, conducted in the framework of the Lusi Lab project (ERC grant n°308126) we use both analytical and numerical methods to better understand the flow dynamics within the main conduit and to try to explain the longevity of the edifice. The 2D numerical model considers a vertical conduit with a reservoir at its base and solves the stokes equations, discretized on a finite element mesh. Although, three phases (solid, liquid and gas) are present in nature, we only consider the liquid phase. The solid phase is treated as rigid particles in suspension in the liquid. The gaseous phase (methane and carbon dioxide) is treated in an analytical manner using the equations of state of the H2O-CO2 and H2O-CH4 systems. Here, we discuss the effects of density, viscosity, gas concentration and clasts concentration and size on the dynamics of the flow in the conduit as well as implications of the conduit stability.

  3. The implications of gas slug ascent in a stratified magma for acoustic and ground deformation source mechanisms in Strombolian eruptions

    Science.gov (United States)

    Capponi, Antonio; Lane, Stephen J.; James, Mike R.

    2017-06-01

    The interpretation of geophysical measurements at active volcanoes is vital for hazard assessment and for understanding fundamental processes such as magma degassing. For Strombolian activity, interpretations are currently underpinned by first-order fluid dynamic models which give relatively straightforward relationships between geophysical signals and gas and magma flow. However, recent petrological and high-speed video evidence has indicated the importance of rheological stratification within the conduit and, here, we show that under these conditions, the straightforward relationships break down. Using laboratory analogue experiments to represent a rheologically-stratified conduit we characterise the distinct variations in the shear stress exerted on the upper sections of the flow tube and in the gas pressures measured above the liquid surface, during different degassing flow configurations. These signals, generated by varying styles of gas ascent, expansion and burst, can reflect field infrasonic measurements and ground motion proximal to a vent. The shear stress signals exhibit timescales and trends in qualitative agreement with the near-vent inflation-deflation cycles identified at Stromboli. Therefore, shear stress along the uppermost conduit may represent a plausible source of near-vent tilt, and conduit shear contributions should be considered in the interpretation of ground deformation, which is usually attributed to pressure sources only. The same range of flow processes can produce different experimental infrasonic waveforms, even for similar masses of gas escape. The experimental data resembled infrasonic waveforms acquired from different vents at Stromboli associated with different eruptive styles. Accurate interpretation of near-vent ground deformation, infrasonic signal and eruptive style therefore requires detailed understanding of: a) spatiotemporal magma rheology in the shallow conduit, and b) shallow conduit geometry, as well as bubble

  4. Metallographic autopsies of full-scale ITER prototype cable-in-conduit conductors after full cyclic testing in SULTAN: II. Significant reduction of strand movement and strand damage in short twist pitch CICCs

    International Nuclear Information System (INIS)

    Sanabria, Carlos; Lee, Peter J; Starch, William; Larbalestier, David C; Devred, Arnaud

    2015-01-01

    Prototype cable-in-conduit-conductors (CICCs) destined for use in the toroidal field and central solenoid coils of the ITER experimental fusion reactor underwent severe cyclic loading in the SULTAN facility. Their autopsies revealed significant and permanent transverse strand migration due to the large Lorentz forces of the SULTAN test. The movement resulted in a 3%–7% void fraction increase on the low pressure (LP) side of the longer twist pitch CICCs. However, short twist pitch conductors exhibited less than 1% void fraction increase in the LP side, as well as a complete absence of the Nb 3 Sn filament fractures observed in the longer twist pitch conductors. We report here a detailed strand-to-cable analysis of short and longer ‘baseline’ twist pitch CICCs. It was found that the use of internal tin (IT) strands in the longer ‘baseline’ twist pitch CICCs can be beneficial possibly because of their superior stiffness—which better resist strand movement—while the use of bronze process strands showed more movement and poorer cyclic test performance. This was not the case for the short twist pitch CICC. Such conductor design seems to work well with both strand types. But it was found that despite the absence of filament fractures, the short twist pitch CICC made from the IT strands studied here developed severe strand distortion during cabling which resulted in diffusion barrier breaks and Sn contamination of the Cu stabilizer during the heat treatment. Conversely, the short twist pitch CICC made from bronze process strands preserved diffusion barrier integrity. (paper)

  5. Impact of statin therapy on central aortic pressures and hemodynamics: principal results of the Conduit Artery Function Evaluation-Lipid-Lowering Arm (CAFE-LLA) Study.

    Science.gov (United States)

    Williams, Bryan; Lacy, Peter S; Cruickshank, J Kennedy; Collier, David; Hughes, Alun D; Stanton, Alice; Thom, Simon; Thurston, Herbert

    2009-01-06

    Statins reduce the risk of cardiovascular events in people with hypertension. This benefit could arise from a beneficial effect of statins on central aortic pressures and hemodynamics. The Conduit Artery Function Evaluation-Lipid-Lowering Arm (CAFE-LLA) study, an Anglo-Scandinavian Cardiac Outcomes Trial (ASCOT) substudy, investigated this hypothesis in a prospective placebo-controlled study of treated patients with hypertension. CAFE-LLA recruited 891 patients randomized to atorvastatin 10 mg/d or placebo from 5 centers in the United Kingdom and Ireland. Radial artery applanation tonometry and pulse-wave analysis were used to derive central aortic pressures and hemodynamic indices at repeated visits over 3.5 years of follow-up. Atorvastatin lowered low-density lipoprotein cholesterol by 32.4 mg/dL (95% confidence interval [CI], 28.6 to 36.3) and total cholesterol by 35.1 mg/dL (95% confidence interval, 30.9 to 39.4) relative to placebo. Time-averaged brachial blood pressure was similar in CAFE-LLA patients randomized to atorvastatin or placebo (change in brachial systolic blood pressure, -0.1 mm Hg [95% CI, -1.8 to 1.6], P=0.9; change in brachial pulse pressure, -0.02 mm Hg [95% CI, -1.6 to 1.6], P=0.9). Atorvastatin did not influence central aortic pressures (change in aortic systolic blood pressure, -0.5 mm Hg [95% CI, -2.3 to 1.2], P=0.5; change in aortic pulse pressure, -0.4 mm Hg [95% CI, -1.9 to 1.0], P=0.6) and had no influence on augmentation index (change in augmentation index, -0.4%; 95% CI, -1.7 to 0.8; P=0.5) or heart rate (change in heart rate, 0.25 bpm; 95% CI, -1.3 to 1.8; P=0.7) compared with placebo. The effect of statin or placebo therapy was not modified by the blood pressure-lowering treatment strategy in the factorial design. Statin therapy sufficient to significantly reduce cardiovascular events in treated hypertensive patients in ASCOT did not influence central aortic blood pressure or hemodynamics in a large representative cohort of ASCOT

  6. Overcoming challenges integrating patient-generated data into the clinical EHR: lessons from the CONtrolling Disease Using Inexpensive IT--Hypertension in Diabetes (CONDUIT-HID) Project.

    Science.gov (United States)

    Marquard, Jenna L; Garber, Lawrence; Saver, Barry; Amster, Brian; Kelleher, Michael; Preusse, Peggy

    2013-10-01

    The CONDUIT-HID intervention integrates patients' electronic blood pressure measurements directly into the clinical EHR using Microsoft HealthVault as an intermediary data store. The goal of this paper is to describe generalizable categories of patient and technical challenges encountered in the development and implementation of this inexpensive, commercial off-the-shelf consumer health informatics intervention, examples of challenges within each category, and how the example challenges were resolved prior to conducting an RCT of the intervention. The research team logged all challenges and mediation strategies during the technical development of the intervention, conducted home visits to observe patients using the intervention, and conducted telephone calls with patients to understand challenges they encountered. We then used these data to iteratively refine the intervention. The research team identified a variety of generalizable categories of challenges associated with patients uploading data from their homes, patients uploading data from clinics because they did not have or were not comfortable using home computers, and patients establishing the connection between HealthVault and the clinical EHR. Specific challenges within these categories arose because: (1) the research team had little control over the device and application design, (2) multiple vendors needed to coordinate their actions and design changes, (3) the intervention use cases were not anticipated by the device and application designers, (4) PHI accessed on clinic computers needed to be kept secure, (5) the research team wanted the data in the clinical EHR to be valid and reliable, (6) patients needed the ability to share only the data they wanted, and (7) the development of some EHR functionalities were new to the organization. While these challenges were varied and complex, the research team was able to successfully resolve each one prior to the start of the RCT. By identifying these

  7. Filter material charging apparatus for filter assembly for radioactive contaminants

    International Nuclear Information System (INIS)

    Goldsmith, J.M.; O'Nan, A. Jr.

    1977-01-01

    A filter charging apparatus for a filter assembly is described. The filter assembly includes a housing with at least one filter bed therein and the filter charging apparatus for adding filter material to the filter assembly includes a tank with an opening therein, the tank opening being disposed in flow communication with opposed first and second conduit means, the first conduit means being in flow communication with the filter assembly housing and the second conduit means being in flow communication with a blower means. Upon activation of the blower means, the blower means pneumatically conveys the filter material from the tank to the filter housing

  8. WATER HAMMER OSCILLATIONS IN THE IRRIGATION FACILITIES

    Science.gov (United States)

    Kurata, Kouichi; Sasaki, Katsuhito; Makihata, Toshiaki

    In case a gate installed at the end of discharge conduit is vibrating during discharge, or an air valve is vibrating during water-filling operation into the conduit pipe between main gate and auxiliary gate, and vibration period tv is larger than tc (water hammer propagation time) that is equivalent to the phenomenon of slow closure, there is a possibility that water hammer oscillation in the discharge conduit could be induced. In this paper, by using two case examples, vibration phenomena transmitted to each part are analyzed, on the basis of water pressure fluctuation and pressure wave propagation due to occurrence of water hammer oscillation.

  9. Composition-structure-property (Zn{sup 2+} and Ca{sup 2+} ion release) evaluation of Si-Na-Ca-Zn-Ce glasses: Potential components for nerve guidance conduits

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X.F.; Kehoe, S. [Cork Institute of Technology, Cork (Ireland); Adhi, S.K. [Department of Instrumentation Science, University of Pune, Pune 411007 (India); Ajithkumar, T.G. [Central NMR Facility, National Chemical Laboratory, Pune 411008 (India); Moane, S. [Shannon ABC Research Group, Limerick Institute of Technology, Limerick (Ireland); O' Shea, H. [Cork Institute of Technology, Cork (Ireland); Boyd, D., E-mail: d.boyd@dal.ca [Department of Applied Oral Sciences, Biomaterials, and Oral Biology, Dalhousie University, Halifax, NS, B3H 3J5 (Canada)

    2011-04-08

    Bioactive glasses have demonstrated tailored therapeutic ion release, primarily with respect to the augmentation of hard tissues. However, controlled degradation and release of therapeutic ions from biomaterials may also play an important role in soft tissue regeneration such as repair of peripheral nerve discontinuities. In this study, three silica based glasses (0.5SiO{sub 2}-0.2CaO-0.13ZnO-XNa{sub 2}O-(0.17-X) CeO{sub 2}) where, (0.04 < X < 0.14) were synthesised and characterised. The local environment of the {sup 29}Si isotope was probed for each glass using {sup 29}Si MAS-NMR, whilst the thermal characteristics of each glass were examined using DTA. Following these analyses, ion release profiles for Ca{sup 2+} and Zn{sup 2+} were evaluated; an equivalent specific surface area of 1 m{sup 2} of each glass powder was incubated (37 deg. C) in 10 ml of citric acid buffer and TRIS-HCI buffer solution (pH 3.0 and pH 7.4 respectively) for incubation periods of up to 30 days. The Zn{sup 2+} concentration of each filtrate was analysed using flame Atomic Absorption Spectroscopy (Varian AA240FS Fast Sequential AAS) and the Ca{sup 2+} concentration of each filtrate was determined using Inductively Coupled Plasma-Mass Spectrometer (Varian 820 ICP-MS). Results obtained from the {sup 29}Si MAS-NMR spectra indicated Q{sup 2} structures pervading the network. An analytical model was proposed to analyse the ion release profiles for each glass, and indicated heterogeneous dissolution of glass networks. The ion release data demonstrates that ion release in the range (19.26-3130 ppm) for Ca{sup 2+} and in the range (5.97-4904 ppm) for Zn{sup 2+} occurred. Release of such elements, at appropriate levels, from peripheral nerve guidance conduits may be advantageous with respect to the repair of peripheral nerve discontinuities.

  10. System for continuous real time air monitoring by means of gamma spectrometry with germanium dosimeter

    International Nuclear Information System (INIS)

    Montalto, M.; Giacomelli, R.; Nocente, M.; Bortoluzzi, S.; Spezzano, P.

    1990-12-01

    Design of automatic system for real time air monitoring of radioactive particulates are relate. Recommendations are made for design and operation of sampling conduits to minimize losses. By means of experimental equipment loss of particles in long sampling conduits, minimum detectable activity and efficiency of gamma radiation detectable are evaluated. (author)

  11. Reconstruction after esophagectomy for esophageal cancer: Retrosternal or posterior mediastinal route?

    Directory of Open Access Journals (Sweden)

    Mei-Lin Chan

    2011-11-01

    Conclusion: For patients with esophageal cancer who undergo an esophagectomy followed by gastric conduit reconstruction, the posterior mediastinal route is superior to the retrosternal route in regard to anastomotic leakage and hospital mortality. Adjuvant radiotherapy did not influence the postoperative functions of the gastric conduit used for reconstruction in either route.

  12. 76 FR 66899 - Certain Circular Welded Non-Alloy Steel Pipe From Brazil, Mexico, the Republic of Korea, and...

    Science.gov (United States)

    2011-10-28

    ... construction, shipbuilding, trucking, farm equipment, and related industries. Unfinished conduit pipe is also..., shipbuilding, trucking, farm-equipment, and related industries. Unfinished conduit pipe is also included in the... Steel Tube Works Co., Ltd 11.63 Pusan Steel Pipe Co., Ltd 4.91 All Others 6.37 Taiwan: Kao Hsing Chang...

  13. System for continuous real time air monitoring by means of gamma spectrometry with germanium dosimeter; Sistema di monitoraggio dell'aria in continuo mediante spettrometria gamma con rilevatore al germanio

    Energy Technology Data Exchange (ETDEWEB)

    Montalto, M; Giacomelli, R; Nocente, M; Bortoluzzi, S; Spezzano, P [ENEA - Area Energia, Ambiente e Salute, Centro Ricerche Energia Saluggia, Vercelli (Italy)

    1990-12-15

    Design of automatic system for real time air monitoring of radioactive particulates are relate. Recommendations are made for design and operation of sampling conduits to minimize losses. By means of experimental equipment loss of particles in long sampling conduits, minimum detectable activity and efficiency of gamma radiation detectable are evaluated. (author)

  14. Three dimensional rotational angiography for assessment of coronary arteries during melody valve implantation: introducing a technique that may improve outcomes.

    Science.gov (United States)

    Pockett, C R; Moore, J W; El-Said, H G

    2017-02-01

    Adverse events from Melody valve implantation may be catastrophic. To date a role for three dimensional rotational angiography of the aortic root (3DRAA) during Melody valve implantation has not been established. To describe the role of 3DRAA in the assessment of Melody valve candidacy and to demonstrate that it may improve outcomes. All patients who underwent cardiac catheterisation for Melody valve implantation and 3DRAA between August 2013 and February 2015 were reviewed. 31 patients had 3DRAA with balloon sizing. Ten were deemed not Melody candidates (5 coronary compression, 2 aortic root distortion with cusp flattening, 2 RVOT was too large, and 1 had complex branch stenosis and a short landing zone). Of the 21 patients who were Melody candidates, 12 had conduits, 6 prosthetic valves and 3 native RVOTs. In patients with conduits, the technique of stenting the conduit prior to dilation was used after measuring the distance between the conduit and the coronary arteries on 3DRAA. In the Melody patients, we had 100% procedural success and no serious adverse events (coronary compression, tears, stent fracture or endocarditis). As a tool for case selection, 3DRAA may facilitate higher procedural success and decreased risk of serious adverse events. Furthermore, 3D rotational angiography allows stenting of the conduit prior to dilation, which may prevent tears and possibly endocarditis.

  15. 77 FR 15291 - Airworthiness Directives; Airbus Airplanes

    Science.gov (United States)

    2012-03-15

    ... wiring conduit and the wing bottom skin. This proposed AD would require modifying the wiring installation... modification of the wiring installation to improve the routing and the protection of the harnesses in the zone... wiring conduit and the wing bottom skin. This condition, in the scope of published FAA SFAR88 [Special...

  16. 78 FR 68691 - Airworthiness Directives; Fokker Services B.V. Airplanes

    Science.gov (United States)

    2013-11-15

    ... a design review, which revealed that, under certain failure conditions, wiring in the main fuel tank could develop a short circuit that might cause a hot spot on the wiring conduit or puncture the wiring conduit wall. This AD requires installing fuses in the power supply wiring and/or return wiring for...

  17. 78 FR 46303 - Airworthiness Directives; Fokker Services B.V. Airplanes

    Science.gov (United States)

    2013-07-31

    ... above, this [EASA] AD requires the installation of fuses in the power supply wiring and/or return wiring... revealed that, under certain failure conditions, wiring in the main fuel tank could develop a short circuit that might cause a hot spot on the wiring conduit or puncture the wiring conduit wall. This proposed AD...

  18. Water releasing electric generating device for nuclear power plant

    International Nuclear Information System (INIS)

    Umehara, Toshihiro; Tomohara, Yasutaka; Usui, Yoshihiko.

    1994-01-01

    Warm sea water discharged after being used for cooling in an equipment of a coastal nuclear powder plant is discharged from a water discharge port to a water discharge pit, and a conduit vessel is disposed in front of the water discharge port for receiving overflown warm sea water. The warm sea water taken to the conduit vessel is converted to a fallen flow and charged to a turbine generator under water, and electric power is generated by the water head energy of the fallen flow before it is discharged to the water discharge pit. The conduit vessel incorporates a foam preventing unit having spiral flow channels therein, so that the warm sea water taken to the conduit vessel is flown into the water discharge pit after consuming the water head energy while partially branched and flown downwardly and gives lateral component to the downwarding flowing direction. Then, warm sea water is made calm when it is flown into the water discharge pit and, accordingly, generation of bubbles on the water surface of the water discharge pit is avoided. (N.H.)

  19. Plunger with simple retention valve

    International Nuclear Information System (INIS)

    Fekete, A.V.

    1987-01-01

    This patent describes a positive displacement retention valve apparatus in which the actual flow equals the theoretical maximum flow through the retention valve. The apparatus includes, in combination, a confined fluid flow conduit, a piston adapted for reciprocal movement within the fluid flow conduit between upstream and downstream limit positions, piston reciprocating means, and pressure responsive check valve means located upstream with respect to the piston in the fluid flow conduit. The pressure responsive check valve means operable to permit fluid flow therethrough in a downstream direction toward the piston, and to preclude fluid flow therethrough in an opposite direction. The piston is composed of parts which are relatively movable with respect to one another. The piston includes a simple retention valve consisting of a plug means, a cylinder having a minimum and a maximum internal cross section flow area therein and being reciprocal within the confined fluid flow conduit, and a seat on the cylinder for the plug means. The piston reciprocating means are operatively connected to the plug means

  20. Magma flow instability and cyclic activity at soufriere hills volcano, montserrat, british west indies

    Science.gov (United States)

    Voight; Sparks; Miller; Stewart; Hoblitt; Clarke; Ewart; Aspinall; Baptie; Calder; Cole; Druitt; Hartford; Herd; Jackson; Lejeune; Lockhart; Loughlin; Luckett; Lynch; Norton; Robertson; Watson; Watts; Young

    1999-02-19

    Dome growth at the Soufriere Hills volcano (1996 to 1998) was frequently accompanied by repetitive cycles of earthquakes, ground deformation, degassing, and explosive eruptions. The cycles reflected unsteady conduit flow of volatile-charged magma resulting from gas exsolution, rheological stiffening, and pressurization. The cycles, over hours to days, initiated when degassed stiff magma retarded flow in the upper conduit. Conduit pressure built with gas exsolution, causing shallow seismicity and edifice inflation. Magma and gas were then expelled and the edifice deflated. The repeat time-scale is controlled by magma ascent rates, degassing, and microlite crystallization kinetics. Cyclic behavior allows short-term forecasting of timing, and of eruption style related to explosivity potential.

  1. Pseudo-aneurisma em tubo valvulado de pericárdio bovino corrugado após reconstrução da aorta ascendente: relato de caso False aneurysm of crimped bovine pericardial conduit after reconstruction of the ascending aorta: case report

    Directory of Open Access Journals (Sweden)

    Noedir A. G. STOLF

    1999-10-01

    Full Text Available Os autores descrevem o caso de paciente que, 9 anos após a correção cirúrgica de um aneurisma de aorta ascendente com tubo valvulado de pericárdio bovino corrugado, evoluiu com a formação de um pseudo-aneurisma de aorta localizado, posteriormente, sobre a linha de sutura do tubo de pericárdio bovino. Foi realizada substituição do tubo de pericárdio bovino por tubo de Dacron valvulado (com prótese mecânica e reimplante dos óstios coronários utilizando-se a técnica de hemi-Cabrol. O tempo de seguimento pós-operatório do paciente é de 12 meses, permanecendo assintomático.The authors describe the case of a patient who had an aneurysm of the ascending aorta repaired with biologic valved crimped bovine pericardial conduit. Nine years after the surgery he presented a false aneurysm of the ascending aorta, located posteriorly on the suture line of the pericardial tube. The patient was reoperated and the pericardial tube was replaced by a valved Dacron composite graft using the hemi- Cabrol technique for the reimplantation of the coronary ostia. At 12 months follow-up the patient remains free of symptoms.

  2. Spine growth mechanisms: friction and seismicity at Mt. Unzen, Japan

    Science.gov (United States)

    Hornby, Adrian; Kendrick, Jackie; Hirose, Takehiro; Henton De Angelis, Sarah; De Angelis, Silvio; Umakoshi, Kodo; Miwa, Takahiro; Wadsworth, Fabian; Dingwell, Don; Lavallee, Yan

    2014-05-01

    The final episode of dome growth during the 1991-1995 eruption of Mt. Unzen was characterised by spine extrusion accompanied by repetitive seismicity. This type of cyclic activity has been observed at several dome-building volcanoes and recent work suggests a source mechanism of brittle failure of magma in the conduit. Spine growth may proceed by densification and closure of permeable pathways within the uppermost conduit magma, leading to sealing of the dome and inflation of the edifice. Amplified stresses on the wall rock and plug cause brittle failure near the conduit wall once static friction forces are overcome, and during spine growth these fractures may propagate to the dome surface. The preservation of these features is rare, and the conduit is typically inaccessible; therefore spines, the extruded manifestation of upper conduit material, provide the opportunity to study direct evidence of brittle processes in the conduit. At Mt. Unzen the spine retains evidence for brittle deformation and slip, however mechanical constraints on the formation of these features and their potential impact on eruption dynamics have not been well constrained. Here, we conduct an investigation into the process of episodic spine growth using high velocity friction apparatus at variable shear slip rate (0.4-1.5 m.s-1) and normal stress (0.4-3.5 MPa) on dome rock from Mt. Unzen, generating frictional melt at velocity >0.4 m.s-1 and normal stress >0.7 MPa. Our results show that the presence of frictional melt causes a deviation from Byerlee's frictional rule for rock friction. Melt generation is a disequilibrium process: initial amphibole breakdown leads to melt formation, followed by chemical homogenization of the melt layer. Ultimately, the experimentally generated frictional melts have a similar final chemistry, thickness and comminuted clast size distribution, thereby facilitating the extrapolation of a single viscoelastic model to describe melt-lubricated slip events at Mt

  3. Simulating groundwater flow in karst aquifers with distributed parameter models—Comparison of porous-equivalent media and hybrid flow approaches

    Science.gov (United States)

    Kuniansky, Eve L.

    2016-09-22

    Understanding karst aquifers, for purposes of their management and protection, poses unique challenges. Karst aquifers are characterized by groundwater flow through conduits (tertiary porosity), and (or) layers with interconnected pores (secondary porosity) and through intergranular porosity (primary or matrix porosity). Since the late 1960s, advances have been made in the development of numerical computer codes and the use of mathematical model applications towards the understanding of dual (primary [matrix] and secondary [fractures and conduits]) porosity groundwater flow processes, as well as characterization and management of karst aquifers. The Floridan aquifer system (FAS) in Florida and parts of Alabama, Georgia, and South Carolina is composed of a thick sequence of predominantly carbonate rocks. Karst features are present over much of its area, especially in Florida where more than 30 first-magnitude springs occur, numerous sinkholes and submerged conduits have been mapped, and numerous circular lakes within sinkhole depressions are present. Different types of mathematical models have been applied for simulation of the FAS. Most of these models are distributed parameter models based on the assumption that, like a sponge, water flows through connected pores within the aquifer system and can be simulated with the same mathematical methods applied to flow through sand and gravel aquifers; these models are usually referred to as porous-equivalent media models. The partial differential equation solved for groundwater flow is the potential flow equation of fluid mechanics, which is used when flow is dominated by potential energy and has been applied for many fluid problems in which kinetic energy terms are dropped from the differential equation solved. In many groundwater model codes (basic MODFLOW), it is assumed that the water has a constant temperature and density and that flow is laminar, such that kinetic energy has minimal impact on flow. Some models have

  4. Water level indicator

    International Nuclear Information System (INIS)

    Murase, Michio; Araki, Hidefumi.

    1996-01-01

    A difference of pressure between a standard pressure conduit in communication with a gas phase of a reactor pressure vessel and a water level pressure conduit in communication with a liquid phase of the pressure vessel is detected by a pressure difference gage. A communication pipe and a standard level vessel are disposed between the pressure vessel and the standard pressure conduit, and a standard liquid surface on the side of the standard pressure conduit is formed in the standard level vessel. A gas releaser is disposed to the gas phase portion of the standard level vessel. The gas releaser equipment is constituted by a porous material, a permeation membrane and a gas exhaustion hole. The gas phase of the standard level vessel is divided by a partition plate into a first gas phase being in contact with a connection portion with the communication pipe and a second gas phase in contact with the gas releaser. A gas flow channel hole and a condensate descending hole are disposed to the partition plate. Since incondensible gases accumulated to the standard level vessel are effectively exhausted, the incondensible gases are prevented from being dissolved into liquid. (I.N.)

  5. Tracheid diameter is the key trait determining the extent of freezing-induced embolism in conifers.

    Science.gov (United States)

    Pittermann, Jarmila; Sperry, John

    2003-09-01

    We tested the hypotheses that freezing-induced embolism is related to conduit diameter, and that conifers and angiosperms with conduits of equivalent diameter will exhibit similar losses of hydraulic conductivity in response to freezing. We surveyed the freeze-thaw response of conifers with a broad range of tracheid diameters by subjecting wood segments (root, stem and trunk wood) to a freeze-thaw cycle at -0.5 MPa in a centrifuge. Embolism increased as mean tracheid diameter exceeded 30 microm. Tracheids with a critical diameter greater than 43 microm were calculated to embolize in response to freezing and thawing at a xylem pressure of -0.5 MPa. To confirm that freezing-induced embolism is a function of conduit air content, we air-saturated stems of Abies lasiocarpa (Hook.) Nutt. (mean conduit diameter 13.7 +/- 0.7 microm) by pressurizing them 1 to 60 times above atmospheric pressure, prior to freezing and thawing. The air saturation method simulated the effect of increased tracheid size because the degree of super-saturation is proportional to a tracheid volume holding an equivalent amount of dissolved air at ambient pressure. Embolism increased when the dissolved air content was equivalent to a mean tracheid diameter of 30 microm at ambient air pressure. Our centrifuge and air-saturation data show that conifers are as vulnerable to freeze-thaw embolism as angiosperms with equal conduit diameter. We suggest that the hydraulic conductivity of conifer wood is maximized by increasing tracheid diameters in locations where freezing is rare. Conversely, the narrowing of tracheid diameters protects against freezing-induced embolism in cold climates.

  6. Volcanic tremor masks its seismogenic source: Results from a study of noneruptive tremor recorded at Mount St. Helens, Washington

    Science.gov (United States)

    Denlinger, Roger P.; Moran, Seth C.

    2014-01-01

    On 2 October 2004, a significant noneruptive tremor episode occurred during the buildup to the 2004–2008 eruption of Mount St. Helens (Washington). This episode was remarkable both because no explosion followed, and because seismicity abruptly stopped following the episode. This sequence motivated us to consider a model for volcanic tremor that does not involve energetic gas release from magma but does involve movement of conduit magma through extension on its way toward the surface. We found that the tremor signal was composed entirely of Love and Rayleigh waves and that its spectral bandwidth increased and decreased with signal amplitude, with broader bandwidth signals containing both higher and lower frequencies. Our modeling results demonstrate that the forces giving rise to this tremor were largely normal to conduit walls, generating hybrid head waves along conduit walls that are coupled to internally reflected waves. Together these form a crucial part of conduit resonance, giving tremor wavefields that are largely a function of waveguide geometry and velocity. We find that the mechanism of tremor generation fundamentally masks the nature of the seismogenic source giving rise to resonance. Thus multiple models can be invoked to explain volcanic tremor, requiring that information from other sources (such as visual observations, geodesy, geology, and gas geochemistry) be used to constrain source models. With concurrent GPS and field data supporting rapid rise of magma, we infer that tremor resulted from drag of nearly solid magma along rough conduit walls as magma was forced toward the surface.

  7. Nitrogen Fate in a Phreatic Fluviokarst Watershed: a Stable Isotope, Sediment Tracing, and Numerical Modeling Approach

    Science.gov (United States)

    Husic, A.; Fox, J.; Ford, W. I., III; Agouridis, C.; Currens, J. C.; Taylor, C. J.

    2017-12-01

    Sediment tracing tools provide an insight into provenance, fate, and transport of sediment and, when coupled to stable isotopes, can elucidate in-stream biogeochemical processes. Particulate nitrogen fate in fluviokarst systems is a relatively unexplored area of research partially due to the complex hydrodynamics at play in karst systems. Karst topography includes turbulent conduits that transport groundwater and contaminants at speeds more typical of open channel flows than laminar Darcian flows. While it is accepted that karst hydro-geomorphology represents a hybrid surface-subsurface system for fluid, further investigation is needed to determine whether, and to what extent, karst systems behave like surface agricultural streams or porous media aquifers with respect to their role in nitrogen cycling. Our objective is to gain an understanding of in-conduit nitrogen processes and their effect on net nitrogen-exports from karst springs to larger waterbodies. The authors apply water, sediment, carbon, and nitrogen tracing techniques to analyze water for nitrate, sediment carbon and nitrogen, and stable sediment nitrogen isotope (δ15N). Thereafter, a new numerical model is formulated that: simulates dissolved inorganic nitrogen and sediment nitrogen transformations in the phreatic karst conduit; couples carbon turnover and nitrogen transformations in the model structure; and simulates the nitrogen stable isotope mass balance for the dissolved and sediment phases. Nitrogen tracing data results show a significant increase in δ15N of sediment nitrogen at the spring outlet relative to karst inputs indicating the potential for isotope fractionation during dissolved N uptake by bed sediments in the conduit and during denitrification within bed sediments. The new numerical modeling structure is then used to reproduce the data results and provide an estimate of the relative dominance of N uptake and denitrification within the surficial sediments of the karst conduit system

  8. Allotransplanted neurons used to repair peripheral nerve injury do not elicit overt immunogenicity.

    Directory of Open Access Journals (Sweden)

    Weimin Liu

    Full Text Available A major problem hindering the development of autograft alternatives for repairing peripheral nerve injuries is immunogenicity. We have previously shown successful regeneration in transected rat sciatic nerves using conduits filled with allogeneic dorsal root ganglion (DRG cells without any immunosuppression. In this study, we re-examined the immunogenicity of our DRG neuron implanted conduits as a potential strategy to overcome transplant rejection. A biodegradable NeuraGen® tube was infused with pure DRG neurons or Schwann cells cultured from a rat strain differing from the host rats and used to repair 8 mm gaps in the sciatic nerve. We observed enhanced regeneration with allogeneic cells compared to empty conduits 16 weeks post-surgery, but morphological analyses suggest recovery comparable to the healthy nerves was not achieved. The degree of regeneration was indistinguishable between DRG and Schwann cell allografts although immunogenicity assessments revealed substantially increased presence of Interferon gamma (IFN-γ in Schwann cell allografts compared to the DRG allografts by two weeks post-surgery. Macrophage infiltration of the regenerated nerve graft in the DRG group 16 weeks post-surgery was below the level of the empty conduit (0.56 fold change from NG; p<0.05 while the Schwann cell group revealed significantly higher counts (1.29 fold change from NG; p<0.001. Major histocompatibility complex I (MHC I molecules were present in significantly increased levels in the DRG and Schwann cell allograft groups compared to the hollow NG conduit and the Sham healthy nerve. Our results confirmed previous studies that have reported Schwann cells as being immunogenic, likely due to MHC I expression. Nerve gap injuries are difficult to repair; our data suggest that DRG neurons are superior medium to implant inside conduit tubes due to reduced immunogenicity and represent a potential treatment strategy that could be preferable to the current gold

  9. Physical and Hydrological Meaning of the Spectral Information from Hydrodynamic Signals at Karst Springs

    Science.gov (United States)

    Dufoyer, A.; Lecoq, N.; Massei, N.; Marechal, J. C.

    2017-12-01

    Physics-based modeling of karst systems remains almost impossible without enough accurate information about the inner physical characteristics. Usually, the only available hydrodynamic information is the flow rate at the karst outlet. Numerous works in the past decades have used and proven the usefulness of time-series analysis and spectral techniques applied to spring flow, precipitations or even physico-chemical parameters, for interpreting karst hydrological functioning. However, identifying or interpreting the karst systems physical features that control statistical or spectral characteristics of spring flow variations is still challenging, not to say sometimes controversial. The main objective of this work is to determine how the statistical and spectral characteristics of the hydrodynamic signal at karst springs can be related to inner physical and hydraulic properties. In order to address this issue, we undertake an empirical approach based on the use of both distributed and physics-based models, and on synthetic systems responses. The first step of the research is to conduct a sensitivity analysis of time-series/spectral methods to karst hydraulic and physical properties. For this purpose, forward modeling of flow through several simple, constrained and synthetic cases in response to precipitations is undertaken. It allows us to quantify how the statistical and spectral characteristics of flow at the outlet are sensitive to changes (i) in conduit geometries, and (ii) in hydraulic parameters of the system (matrix/conduit exchange rate, matrix hydraulic conductivity and storativity). The flow differential equations resolved by MARTHE, a computer code developed by the BRGM, allows karst conduits modeling. From signal processing on simulated spring responses, we hope to determine if specific frequencies are always modified, thanks to Fourier series and multi-resolution analysis. We also hope to quantify which parameters are the most variable with auto

  10. Balance between automation and human actions in nuclear power plant operation. Results of international cooperation; Equilibre entre automatisation et action humaine dans la conduite des centrale nucleaires, resultats de la cooperation internationale

    Energy Technology Data Exchange (ETDEWEB)

    Sun, B [CEA Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. d' Analyse de Surete; Bastl, W [Gesellschaft fuer Reaktorsicherheit m.b.H. (GRS), Garching (Germany); Olmstead, R [Atomic Energy of Canada Ltd, Mississauga (Canada); Oudiz, A [Electric Power Research Inst., Palo Alto, CA (United States); Jenkinson, J [Nuclear Electric PLC, Gloucester (United Kingdom); Kossilov, A [International Atomic Energy Agency, Vienna (Austria)

    1990-07-01

    Automation has long been an established feature of power plants. In some applications, the use of automation has been the significant factor which has enabled plant technology to progress to its current state. Societal demands for increased levels of safety have led to greater use of redundancy and diversity and this, in turn, has increased levels of automation. However, possibly the greatest contributory factor in increased automation has resulted from improvements in information technology. Much recent attention has been focused on the concept of inherently safe reactors, which may simplify safety system requirements and information and control system complexity. The allocation of tasks between man and machine may be one of the most critical activity in the design of new nuclear plants and major retro-fits and it therefore warrants a design approach which is commensurate in quality with the high levels of safety and production performance sought from nuclear plants. Facing this climate, in 1989 the International Atomic Energy Agency (IAEA) formed an advisory group from member countries with extensive experience in nuclear power plant automation. The task of this group was to advise on the appropriate balance between manual and automatic actions in plant operation. (author) [French] L'automatisation a longtemps ete une caracteristique bien etablie des centrales nucleaires. Dans certaines applications, l'utilisation de l'automatisation a ete le facteur decisif qui a permis a la technologie des centrales de progresser jusqu'a son etat actuel. Les exigences de l'opinion publique en matiere de securite renforcee ont conduit a l'utilisation d'une plus grande redondance et a une plus grande diversification et ceci, en retour, a encore accru le niveau d'automatisation. Toutefois, il est possible que le facteur preponderant de cet accroissement de l'automatisation soit constitue par les progres effectues dans la technologie de l'information. Plus recemment, l'attention s

  11. Earthquake prediction using extinct monogenetic volcanoes: A possible new research strategy

    Science.gov (United States)

    Szakács, Alexandru

    2011-04-01

    Volcanoes are extremely effective transmitters of matter, energy and information from the deep Earth towards its surface. Their capacities as information carriers are far to be fully exploited so far. Volcanic conduits can be viewed in general as rod-like or sheet-like vertical features with relatively homogenous composition and structure crosscutting geological structures of far more complexity and compositional heterogeneity. Information-carrying signals such as earthquake precursor signals originating deep below the Earth surface are transmitted with much less loss of information through homogenous vertically extended structures than through the horizontally segmented heterogeneous lithosphere or crust. Volcanic conduits can thus be viewed as upside-down "antennas" or waveguides which can be used as privileged pathways of any possible earthquake precursor signal. In particular, conduits of monogenetic volcanoes are promising transmitters of deep Earth information to be received and decoded at surface monitoring stations because the expected more homogenous nature of their rock-fill as compared to polygenetic volcanoes. Among monogenetic volcanoes those with dominantly effusive activity appear as the best candidates for privileged earthquake monitoring sites. In more details, effusive monogenetic volcanic conduits filled with rocks of primitive parental magma composition indicating direct ascent from sub-lithospheric magma-generating areas are the most suitable. Further selection criteria may include age of the volcanism considered and the presence of mantle xenoliths in surface volcanic products indicating direct and straightforward link between the deep lithospheric mantle and surface through the conduit. Innovative earthquake prediction research strategies can be based and developed on these grounds by considering conduits of selected extinct monogenetic volcanoes and deep trans-crustal fractures as privileged emplacement sites of seismic monitoring stations

  12. Cyclic Activity of Mud Volcanoes: Evidences from Trinidad (SE Caribbean)

    Science.gov (United States)

    Deville, E.

    2007-12-01

    Fluid and solid transfer in mud volcanoes show different phases of activity, including catastrophic events followed by periods of relative quiescence characterized by moderate activity. This can be notably shown by historical data onshore Trinidad. Several authors have evoked a possible link between the frequencies of eruption of some mud volcanoes and seismic activity, but in Trinidad there is no direct correlation between mud eruptions and seisms. It appears that each eruptive mud volcano has its own period of catastrophic activity, and this period is highly variable from one volcano to another. The frequency of activity of mud volcanoes seems essentially controlled by local pressure regime within the sedimentary pile. At the most, a seism can, in some cases, activate an eruption close to its term. The dynamics of expulsion of the mud volcanoes during the quiescence phases has been studied notably from temperature measurements within the mud conduits. The mud temperature is concurrently controlled by, either, the gas flux (endothermic gas depressurizing induces a cooling effect), or by the mud flux (mud is a vector for convective heat transfer). Complex temperature distribution was observed in large conduits and pools. Indeed, especially in the bigger pools, the temperature distribution characterizes convective cells with an upward displacement of mud above the deep outlet, and ring-shaped rolls associated with the burial of the mud on the flanks of the pools. In simple, tube-like shaped, narrow conduits, the temperature is more regular, but we observed different types of profiles, with either downward increasing or decreasing temperatures. If the upward flow of mud would be regular, we should expect increasing temperatures and progressively decreasing gradient with depth within the conduits. However, the variable measured profiles from one place to another, as well as time-variable measured temperatures within the conduits and especially, at the base of the

  13. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  14. This Afghanistan War in the Light of America’s Post Vietnam Military Culture: The Logic of Asymmetrical Death and Commemoration

    Directory of Open Access Journals (Sweden)

    Mark Meigs

    2007-01-01

    Full Text Available Dans cet article, Mark Meigs explique les ressorts profonds des choix stratégiques américains dans la conduite de la guerre en Afghanistan. Il montre en particulier comment ceux-ci sont basés sur l'expérience américaine au Vietnam, qui a conduit à une profonde restructuration de la doctrine, et font l'originalité de la culture militaire américaine.

  15. Reduced Toxicity Fuel Satellite Propulsion System Including Fuel Cell Reformer with Alcohols Such as Methanol

    Science.gov (United States)

    Schneider, Steven J. (Inventor)

    2001-01-01

    A reduced toxicity fuel satellite propulsion system including a reduced toxicity propellant supply for consumption in an axial class thruster and an ACS class thruster. The system includes suitable valves and conduits for supplying the reduced toxicity propellant to the ACS decomposing element of an ACS thruster. The ACS decomposing element is operative to decompose the reduced toxicity propellant into hot propulsive gases. In addition the system includes suitable valves and conduits for supplying the reduced toxicity propellant to an axial decomposing element of the axial thruster. The axial decomposing element is operative to decompose the reduced toxicity propellant into hot gases. The system further includes suitable valves and conduits for supplying a second propellant to a combustion chamber of the axial thruster, whereby the hot gases and the second propellant auto-ignite and begin the combustion process for producing thrust.

  16. Nuclear reactor

    International Nuclear Information System (INIS)

    Garabedian, G.

    1988-01-01

    A liquid reactor is described comprising: (a) a reactor vessel having a core; (b) one or more satellite tanks; (c) pump means in the satellite tank; (d) heat exchanger means in the satellite tank; (e) an upper liquid metal conduit extending between the reactor vessel and the satellite tank; (f) a lower liquid metal duct extending between the reactor vessel and satellite tanks the upper liquid metal conduit and the lower liquid metal duct being arranged to permit free circulation of liquid metal between the reactor vessel core and the satellite tank by convective flow of liquid metal; (g) a separate sealed common containment vessel around the reactor vessel, conduits and satellite tanks; (h) the satellite tank having space for a volume of liquid metal that is sufficient to dampen temperature transients resulting from abnormal operating conditions

  17. Air-water two-phase flow through a pipe junction

    International Nuclear Information System (INIS)

    Suu, Tetsuo

    1991-01-01

    The distribution of the local void fraction across the section of the conduit was studied experimentally in air-water two-phase flow flowing through a pipe junction with the branching angle of 90deg and the area ratio of unity. As in the previous report, the main conduit of the junction was set up vertically and upward air-water bubbly and slug flows were arranged in the main upstream section. If the flow regime, the quality and the ratio of lateral mass flow discharge of water to total mass flow discharge of water are the same, the larger the Reynolds number is, the more violent the variety of the local void fraction distribution adjacent to the branching part in the lateral conduit is. However, the variety in the main downstream section is scarcely influenced by the Reynolds number. (author)

  18. Hermetically sealed superconducting magnet motor

    Science.gov (United States)

    DeVault, Robert C.; McConnell, Benjamin W.; Phillips, Benjamin A.

    1996-01-01

    A hermetically sealed superconducting magnet motor includes a rotor separated from a stator by either a radial gap, an axial gap, or a combined axial and radial gap. Dual conically shaped stators are used in one embodiment to levitate a disc-shaped rotor made of superconducting material within a conduit for moving cryogenic fluid. As the rotor is caused to rotate when the field stator is energized, the fluid is pumped through the conduit.

  19. Forum on unsteady flow - 1985

    International Nuclear Information System (INIS)

    Rothe, P.H.

    1985-01-01

    This book presents the papers given at a conference on fluid flow and hydraulics. Topics considered at the conference included a numerical study of pressure transients in a borehole due to pipe movement, laminar fluid transients in conduits of unconventional shape, water hammer analysis needs in nuclear power plant design, modeling blockage in unsteady slurry flow in conduits, and check valve slamming in a BWR feedwater system following a postulated pipe break

  20. Evolution of the magma feeding system during a Plinian eruption: The case of Pomici di Avellino eruption of Somma-Vesuvius, Italy

    Science.gov (United States)

    Massaro, S.; Costa, A.; Sulpizio, R.

    2018-01-01

    The current paradigm for volcanic eruptions is that magma erupts from a deep magma reservoir through a volcanic conduit, typically modelled with fixed rigid geometries such as cylinders. This simplistic view of a volcanic eruption does not account for the complex dynamics that usually characterise a large explosive event. Numerical simulations of magma flow in a conduit combined with volcanological and geological data, allow for the first description of a physics-based model of the feeding system evolution during a sustained phase of an explosive eruption. The method was applied to the Plinian phase of the Pomici di Avellino eruption (PdA, 3945 ±10 cal yr BP) from Somma-Vesuvius (Italy). Information available from volcanology, petrology, and lithology studies was used as input data and as constraints for the model. In particular, Mass Discharge Rates (MDRs) assessed from volcanological methods were used as target values for numerical simulations. The model solutions, which are non-unique, were constrained using geological and volcanological data, such as volume estimates and types of lithic components in the fall deposits. Three stable geometric configurations of the feeding system (described assuming elliptical cross-section of variable dimensions) were assessed for the Eruptive Units 2 and 3 (EU2, EU3), which form the magmatic Plinian phase of PdA eruption. They describe the conduit system geometry at time of deposition of EU2 base, EU2 top, and EU3. A 7-km deep dyke (length 2 a = 200-4 00 m, width 2 b = 10- 12 m), connecting the magma chamber to the surface, characterised the feeding system at the onset of the Plinian phase (EU2 base). The feeding system rapidly evolved into hybrid geometric configuration, with a deeper dyke (length 2 a = 600- 800 m, width 2 b = 50 m) and a shallower cylindrical conduit (diameter D = 50 m, dyke-to-cylinder transition depth ∼2100 m), during the eruption of the EU2 top. The deeper dyke reached the dimensions of 2 a = 2000 m and

  1. Total pelvic exenteration: the Albert Einstein College of Medicine/Montefiore Medical Center Experience (1987 to 2003).

    Science.gov (United States)

    Goldberg, Gary L; Sukumvanich, Paniti; Einstein, Mark H; Smith, Harriet O; Anderson, Patrick S; Fields, Abbie L

    2006-05-01

    To review the trends, modifications and results of 103 consecutive total pelvic exenterations (TPE) performed at the Montefiore Medical Center and Albert Einstein College of Medicine from 1987 to 2003. All patients who underwent TPE from January 1987 to December 2003 were included. The medical record, complications, follow-up, clinical status and demographic information were entered in a database. The procedure performed, the method of urinary diversion, colonic diversion, pelvic floor support and vaginal reconstruction were documented. Surviving patients were surveyed regarding their satisfaction with the urinary diversion, the vaginal reconstruction and their sexual function since the surgery. 103 pts were identified. Indications for TPE were recurrent cancers of the cervix (95), endometrium (2), colon and rectum (5), vulva (1). Overall 5-year survival was 47%. 5-year survival for pts with recurrent cervix cancer was 48%. Six pts (6%) recurred >5 years after the TPE. 14 pts (14%) had ureteral anastomotic leaks (no difference between ileal conduit 9/65 (14%) versus 5/38 (13%) continent conduit (P = 0.92). 34 pts (89%) with continent conduits were "continent." 14 pts (17%) had wound complications. 4 pts (4%) had parastomal hernias. 5/11 (46%) pts who had a low rectal reanastomosis developed recurrence in the pelvis. 21/39 (54%) of pts with continent conduits would choose an ileal conduit if they had the option again. Long-term renal function was similar in pts with ileal and continent conduits. Mesh of any type for pelvic floor reconstruction is associated with infection and bowel/urinary fistulas. VRAM flaps for neovagina fill the pelvic dead space, reduce the risk of fistulas and 20/36 pts (55%) are sexually active. Our overall 5-year survival is encouraging, and modifications in surgical technique have improved the reconstructive phase. Low rectal anastomoses at TPE adversely affects survival. Many of our pts with continent urinary diversions would not choose

  2. Quantifying mantle structure and dynamics using plume tracing in seismic tomography

    Science.gov (United States)

    O'Farrell, K. A.; Eakin, C. M.; Jackson, M. G.; Jones, T. D.; Lekic, V.; Lithgow-Bertelloni, C. R.

    2017-12-01

    Directly linking deep mantle processes with surface features and dynamics is a complex problem. Hotspot volcanism gives us surface observables of mantle signatures, but the depth and source of the mantle plumes feeding these hotspots are highly debated. To address these issues, it is necessary to consider the entire journey of a plume through the mantle. By analyzing the behavior of mantle plumes we can constrain the vigor of mantle convection, the net rotation of the mantle and the role of thermal versus chemical anomalies as well as the bulk physical properties such as the viscosity profile. To do this, we developed a new algorithm to trace plume-like features in shear-wave (Vs) seismic tomography models based on picking local minima in the velocity and searching for continuous features with depth. We applied this method to recent tomographic models and find 60+ continuous plume conduits that are > 750 km long. Approximately a third of these can be associated with known hotspots at the surface. We analyze the morphology of these continuous conduits and infer large scale mantle flow patterns and properties. We find the largest lateral deflections in the conduits occur near the base of the lower mantle and in the upper mantle (near the thermal boundary layers). The preferred orientation of the plume deflections show large variability at all depths and indicate no net mantle rotation. Plate by plate analysis shows little agreement in deflection below particular plates, indicating these deflected features might be long lived and not caused by plate shearing. Changes in the gradient of plume deflection are inferred to correspond with viscosity contrasts in the mantle and found below the transition zone as well as at 1000 km depth. From this inferred viscosity structure, we explore the dynamics of a plume through these viscosity jumps. We also retrieve the Vs profiles for the conduits and compare with the velocity profiles predicted for different mantle adiabat

  3. Spatial variability in degassing at Erebus volcano, Antarctica

    Science.gov (United States)

    Ilanko, Tehnuka; Oppenheimer, Clive; Kyle, Philip; Burgisser, Alain

    2015-04-01

    Erebus volcano on Ross Island, Antarctica, hosts an active phonolitic lava lake, along with a number of persistently degassing vents in its summit crater. Flank degassing also occurs through ice caves and towers. The longevity of the lake, and its stable convection, have been the subject of numerous studies, including Fourier transform infrared (FTIR) spectroscopy of the lava lake. Two distinct gas compositions were previously identified in the main lava lake plume (Oppenheimer et al., 2009; 2011): a persistent 'conduit' gas with a more oxidised signature, ascribed to degassing through a permeable magma conduit; and a H2O- and SO2- enriched 'lake' composition that increases and decreases cyclically due to shallow degassing of incoming magma batches. During the past decade of annual field seasons on Erebus, gas compositions have been measured through FTIR spectroscopy at multiple sites around Erebus volcano, including flank degassing through an ice cave (Warren Cave). We present measurements from four such vents, and compare their compositions to those emitted from the main lava lake. Summit degassing involves variable proportions of H2O, CO2, CO, SO2, HF, HCl, OCS. Cyclicity is evident in some summit vents, but with signatures indicative of shallower magmatic degassing than that of the lava lake. By contrast, flank degassing at Warren Cave is dominated by H2O, CO2, and CH4. The spatial variability in gas compositions within the summit crater suggests an alternative origin for 'conduit' and 'lake' degassing to previous models that assume permeability in the main conduit. Rather, the two compositions observed in main lake degassing may be a result of decoupled 'conduit' gas and pulses of magma rising through discrete fractures before combining in the lake floor or the main plume. Smaller vents around the crater thus emit isolated 'lake' or 'conduit' compositions while their combined signature is observed in the lava lake. We suggest that this separation between gas

  4. Laboratory Volcano Geodesy

    OpenAIRE

    Johannessen, Rikke Færøvik

    2014-01-01

    Magma transport in volcanic plumbing systems induces surface deformation, which can be monitored by geodetic techniques, such as GPS and InSAR. These geode- tic signals are commonly analyzed through geodetic models in order to constrain the shape of, and the pressure in, magma plumbing systems. These models, how- ever, suffer critical limitations: (1) the modelled magma conduit shapes cannot be compared with the real conduits, so the geodetic models cannot be tested nor validated; (2) the mod...

  5. In situ reactor

    Science.gov (United States)

    Radtke, Corey William; Blackwelder, David Bradley

    2004-01-27

    An in situ reactor for use in a geological strata, is described and which includes a liner defining a centrally disposed passageway and which is placed in a borehole formed in the geological strata; and a sampling conduit is received within the passageway defined by the liner and which receives a geological specimen which is derived from the geological strata, and wherein the sampling conduit is in fluid communication with the passageway defined by the liner.

  6. Solar fuels generator

    Science.gov (United States)

    Lewis, Nathan S.; Spurgeon, Joshua M.

    2016-10-25

    The solar fuels generator includes an ionically conductive separator between a gaseous first phase and a second phase. A photoanode uses one or more components of the first phase to generate cations during operation of the solar fuels generator. A cation conduit is positioned provides a pathway along which the cations travel from the photoanode to the separator. The separator conducts the cations. A second solid cation conduit conducts the cations from the separator to a photocathode.

  7. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  8. Article, component, and method of forming an article

    Science.gov (United States)

    Lacy, Benjamin Paul; Itzel, Gary Michael; Kottilingam, Srikanth Chandrudu; Dutta, Sandip; Schick, David Edward

    2018-05-22

    An article and method of forming an article are provided. The article includes a body portion separating an inner region and an outer region, an aperture in the body portion, the aperture fluidly connecting the inner region to the outer region, and a conduit extending from an outer surface of the body portion at the aperture and being arranged and disposed to controllably direct fluid from the inner region to the outer region. The method includes providing a body portion separating an inner region and an outer region, providing an aperture in the body portion, and forming a conduit over the aperture, the conduit extending from an outer surface of the body portion and being arranged and disposed to controllably direct fluid from the inner region to the outer region. The article is arranged and disposed for insertion within a hot gas path component.

  9. Facilitation of facial nerve regeneration using chitosan-β-glycerophosphate-nerve growth factor hydrogel.

    Science.gov (United States)

    Chao, Xiuhua; Xu, Lei; Li, Jianfeng; Han, Yuechen; Li, Xiaofei; Mao, YanYan; Shang, Haiqiong; Fan, Zhaomin; Wang, Haibo

    2016-06-01

    Conclusion C/GP hydrogel was demonstrated to be an ideal drug delivery vehicle and scaffold in the vein conduit. Combined use autologous vein and NGF continuously delivered by C/GP-NGF hydrogel can improve the recovery of facial nerve defects. Objective This study investigated the effects of chitosan-β-glycerophosphate-nerve growth factor (C/GP-NGF) hydrogel combined with autologous vein conduit on the recovery of damaged facial nerve in a rat model. Methods A 5 mm gap in the buccal branch of a rat facial nerve was reconstructed with an autologous vein. Next, C/GP-NGF hydrogel was injected into the vein conduit. In negative control groups, NGF solution or phosphate-buffered saline (PBS) was injected into the vein conduits, respectively. Autologous implantation was used as a positive control group. Vibrissae movement, electrophysiological assessment, and morphological analysis of regenerated nerves were performed to assess nerve regeneration. Results NGF continuously released from C/GP-NGF hydrogel in vitro. The recovery rate of vibrissae movement and the compound muscle action potentials of regenerated facial nerve in the C/GP-NGF group were similar to those in the Auto group, and significantly better than those in the NGF group. Furthermore, larger regenerated axons and thicker myelin sheaths were obtained in the C/GP-NGF group than those in the NGF group.

  10. Multiscale Behavior of Viscous Fluids Dynamics: Experimental Observations

    Science.gov (United States)

    Arciniega-Ceballos, Alejandra; Spina, Laura; Scheu, Bettina; Dingwell, Donald B.

    2016-04-01

    The dynamics of Newtonian fluids with viscosities of mafic to intermediate silicate melts (10-1000 Pa s) during slow decompression present multi-time scale processes. To observe these processes we have performed several experiments on silicon oil saturated with Argon gas for 72 hours, in a Plexiglas autoclave. The slow decompression, dropping from 10 MPa to ambient pressure, acting as the excitation mechanism, triggered several processes with their own distinct timescales. These processes generate complex non-stationary microseismic signals, which have been recorded with 7 high-dynamic piezoelectric sensors located along the conduit flanked by high-speed video recordings. The analysis in time and frequency of these time series and their correlation with the associated high-speed imaging enables the characterization of distinct phases and the extraction of the individual processes during the evolution of decompression of these viscous fluids. We have observed fluid-solid elastic interaction, degassing, fluid mass expansion and flow, bubble nucleation, growth, coalescence and collapse, foam building and vertical wagging. All these processes (in fine and coarse scales) are sequentially coupled in time, occur within specific pressure intervals, and exhibit a localized distribution along the conduit. Their coexistence and interactions constitute the stress field and driving forces that determine the dynamics of the conduit system. Our observations point to the great potential of this experimental approach in the understanding of volcanic conduit dynamics and volcanic seismicity.

  11. A Systematic Review of Infective Endocarditis in Patients With Bovine Jugular Vein Valves Compared With Other Valve Types.

    Science.gov (United States)

    Sharma, Ashutosh; Cote, Anita T; Hosking, Martin C K; Harris, Kevin C

    2017-07-24

    The aim of this study was to systematically evaluate the incidence of infective endocarditis (IE) in right ventricle-to-pulmonary artery conduits and valves, comparing bovine jugular vein (BJV) valves with all others. Recent evidence suggests that the incidence of IE is higher in patients with congenital heart disease who have undergone implantation of BJV valves in the pulmonary position compared with other valves. Systematic searches of published research were conducted using electronic databases (MEDLINE, Embase, and CINAHL) and citations cross-referenced current to April 2016. Included studies met the following criteria: patients had undergone right ventricle-to-pulmonary artery conduit or percutaneous pulmonary valve implantation, and investigators reported on the type of conduit or valve implanted, method of intervention (surgery or catheter based), IE incidence, and follow-up time. Fifty studies (Levels of Evidence: 2 to 4) were identified involving 7,063 patients. The median cumulative incidence of IE was higher for BJV compared with other valves (5.4% vs. 1.2%; p endocarditis with BJV valves than other types of right ventricle-to-pulmonary artery conduits. There was no difference in the incidence of endocarditis between catheter-based bovine valves and surgically implanted bovine valves, suggesting that the substrate for future infection is related to the tissue rather than the method of implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Exploiting the bead-injection approach in the integrated sequential injection Lab-on-Valve format using hydrophobic packing materials for on-line matrix removal and preconcentration of trace levels of cadmium in environmental and biological samples via formation of non-charged chelates prior

    DEFF Research Database (Denmark)

    Miró, Manuel; Jonczyk, Sylwia; Wang, Jianhua

    2003-01-01

    The concept of renewable microcolumns within the conduits of an automated single injection lab-on-valve system was exploited in a sorption/elution fashion using sorbents of hydrophobic nature. The scheme's practical applicability was demonstrated for the electrothermal atomic absorption spectrome......The concept of renewable microcolumns within the conduits of an automated single injection lab-on-valve system was exploited in a sorption/elution fashion using sorbents of hydrophobic nature. The scheme's practical applicability was demonstrated for the electrothermal atomic absorption...

  13. In Situ Corrosion and Heat Loss Assessment of Two Nonstandard Underground Heat Distribution System Piping Designs: Supplement-Appendices for Final Report on Project F07-AR01

    Science.gov (United States)

    2011-06-01

    negative mission impacts . This report documents the assessment of two similar nonstandard UHDS piping system designs — one at Fort Carson, CO, and one at...psig and monitored for 2 hours to determine whether the conduit piping system is protected from ground water infiltration and its degrading impacts ...Conduits to/from this pit were tested from adjacent pits. 2. Supply, Return drains tested on 8/15/07: All Dry N S EW MH-3N ERDC/CERL TR-11-14 H13

  14. 18 CFR 358.6 - No conduit rule.

    Science.gov (United States)

    2010-04-01

    ... of an affiliate of a transmission provider that is engaged in marketing functions, is prohibited from disclosing non-public transmission function information to any of the transmission provider's marketing... non-public transmission function information to its marketing function employees. (b) An employee...

  15. Low temperature distillation of powdered materials

    Energy Technology Data Exchange (ETDEWEB)

    1929-04-11

    In the low temperature distillation of powdered material such as coal, brown coal, or oil shale, dust carried by the gases and vapors is precipitated by supplying liquid hydrocarbons to the effluent gases, for example, to a dust remover through which the distillates pass. The material is supplied through a hopper and moved through a retort by a worm feed, and is discharged into a sump. Scavenging gases such as steam may be introduced through a pipe. Two conveyor worms moving in opposite directions are provided in an outlet conduit which may be surrounded by a cooling jacket. Heavy hydrocarbons condense on the walls of the conduit and on the conveyor worms and serve as dust catchers for the distillates, the lighted volatiles escaping through an outlet. The high boiling point oils flow back to and are cracked in the retort. Oils such as tar oils may be sprayed into the conduit or directly adjacent the entry of the material from feeding hopper.

  16. Intraluminal milrinone for dilation of the radial artery graft.

    Science.gov (United States)

    García-Rinaldi, R; Soltero, E R; Carballido, J; Mojica, J

    1999-01-01

    There is renewed interest in the use of the radial artery as a conduit for coronary artery bypass surgery. The radial artery is, however, a very muscular artery, prone to vasospasm. Milrinone, a potent vasodilator, has demonstrated vasodilatory properties superior to those of papaverine. In this report, we describe our technique of radial artery harvesting and the adjunctive use of intraluminal milrinone as a vasodilator in the preparation of this conduit for coronary artery bypass grafting. We have used these techniques in 25 patients who have undergone coronary artery bypass grafting using the radial artery. No hand ischemic complications have been observed in this group. Intraluminal milrinone appears to dilate and relax the radial artery, rendering this large conduit spasm free and very easy to use. We recommend the skeletonization technique for radial artery harvesting and the use of intraluminal milrinone as a radial artery vasodilator in routine myocardial revascularization. PMID:10524740

  17. Acellular Nerve Allografts in Peripheral Nerve Regeneration: A Comparative Study

    Science.gov (United States)

    Moore, Amy M.; MacEwan, Matthew; Santosa, Katherine B.; Chenard, Kristofer E.; Ray, Wilson Z.; Hunter, Daniel A.; Mackinnon, Susan E.; Johnson, Philip J.

    2011-01-01

    Background Processed nerve allografts offer a promising alternative to nerve autografts in the surgical management of peripheral nerve injuries where short deficits exist. Methods Three established models of acellular nerve allograft (cold-preserved, detergent-processed, and AxoGen® -processed nerve allografts) were compared to nerve isografts and silicone nerve guidance conduits in a 14 mm rat sciatic nerve defect. Results All acellular nerve grafts were superior to silicone nerve conduits in support of nerve regeneration. Detergent-processed allografts were similar to isografts at 6 weeks post-operatively, while AxoGen®-processed and cold-preserved allografts supported significantly fewer regenerating nerve fibers. Measurement of muscle force confirmed that detergent-processed allografts promoted isograft-equivalent levels of motor recovery 16 weeks post-operatively. All acellular allografts promoted greater amounts of motor recovery compared to silicone conduits. Conclusions These findings provide evidence that differential processing for removal of cellular constituents in preparing acellular nerve allografts affects recovery in vivo. PMID:21660979

  18. Tissue engineered vascular grafts: Origins, development, and current strategies for clinical application.

    Science.gov (United States)

    Benrashid, Ehsan; McCoy, Christopher C; Youngwirth, Linda M; Kim, Jina; Manson, Roberto J; Otto, James C; Lawson, Jeffrey H

    2016-04-15

    Since the development of a dependable and durable synthetic non-autogenous vascular conduit in the mid-twentieth century, the field of vascular surgery has experienced tremendous growth. Concomitant with this growth, development in the field of bioengineering and the development of different tissue engineering techniques have expanded the armamentarium of the surgeon for treating a variety of complex cardiovascular diseases. The recent development of completely tissue engineered vascular conduits that can be implanted for clinical application is a particularly exciting development in this field. With the rapid advances in the field of tissue engineering, the great hope of the surgeon remains that this conduit will function like a true blood vessel with an intact endothelial layer, with the ability to respond to endogenous vasoactive compounds. Eventually, these engineered tissues may have the potential to supplant older organic but not truly biologic technologies, which are used currently. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Pump having pistons and valves made of electroactive actuators

    Science.gov (United States)

    Bar-Cohen, Yoseph (Inventor)

    1997-01-01

    The present invention provides a pump for inducing a displacement of a fluid from a first medium to a second medium, including a conduit coupled to the first and second media, a transducing material piston defining a pump chamber in the conduit and being transversely displaceable for increasing a volume of the chamber to extract the fluid from the first medium to the chamber and for decreasing the chamber volume to force the fluid from the chamber to the second medium, a first transducing material valve mounted in the conduit between the piston and the first medium and being transversely displaceable from a closed position to an open position to admit the fluid to the chamber, and control means for changing a first field applied to the piston to displace the piston for changing the chamber volume and for changing a second field applied to the first valve to change the position of the first valve.

  20. Report on the results of the FY 1999 R and D of the medical welfare equipment technology and the development of an implantable total artificial heart system using a non-pulsatile pump. R and D of an implantable total artificial heart system using a non-pulsatile pump (R and D of the functional/cure artificial heart); Iryo fukushi kiki gijutsu no kenkyu kaihatsu tainai umekomigata jinko shinzo system 1999 nendo seika hokokusho. 5. Renzokuryu pump wo mochiita tainai umekomigata jinko shinzo system no kenkyu kaihatsu (kinoteki chiryoteki jinko shinzo no kenkyu kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The R and D of element technology were made on non-pulsatile pump, drive/controller, energy supply storage system, structural coating materials, etc., and the prescribed target was achieved. In the R and D of a total system, a blood-removing conduit with movability was designed to avoid the functional inlet obstruction, and the animal experiment was carried out. In the short-term chronic animal experiment on the implantation of a single bypass model using this artificial conduit and in the animal experiment for implantation of functional/cure artificial heart, it was confirmed that the operation was conducted easily, the flow rate of the blood of the artificial heart is extremely stable, and the blood-removing conduit functions favorably. In the R and D on Tele-TAH with the aim of future home medical treatment, it became possible to acquire via monitor the pump drive information and blood circulation state information on the animals tested in the breeding farm. The remote medical simulation was made. (NEDO)