WorldWideScience

Sample records for conditioning system pcs

  1. Adding PCs to SLC Control System

    International Nuclear Information System (INIS)

    Lahey, T.; Levitt, S.; MacKenzie, R.; Spencer, N.; Underwood, K.

    1993-05-01

    The SLAC Controls Department has interfaced IBM-Compatible PCs to the SLC Control System, for use by the Final Focus Test Beam (FFTB) experimenters, who are building new accelerator equipment and developing and testing it at their home institutions. They will bring the equipment to SLAC and integrate it into the control system using a new software package. The machine physicists and operators will use the existing SLC control system applications and database device types to control and monitor the equipment. The PCs support a limited control environment: they run DOS and exchange messages with the existing control system via TCP/IP over ethernet, using the new SLC Area Message Service. This mechanism will also allow SLC to implement other commercial device controllers that can communicate over ethernet and run the same software interface code

  2. An XML-based configuration system for MAST PCS

    International Nuclear Information System (INIS)

    Storrs, J.; McArdle, G.

    2008-01-01

    MAST PCS, a port of General Atomics' generic Plasma Control System, is a large software system comprising many source files in C and IDL. Application parameters can affect multiple source files in complex ways, making code development and maintenance difficult. The MAST PCS configuration system aims to make the task of the application developer easier, through the use of XML-based configuration files and a configuration tool which processes them. It is presented here as an example of a useful technique with wide application

  3. A novel personal cooling system (PCS) incorporated with phase change materials (PCMs) and ventilation fans: An investigation on its cooling efficiency.

    Science.gov (United States)

    Lu, Yehu; Wei, Fanru; Lai, Dandan; Shi, Wen; Wang, Faming; Gao, Chuansi; Song, Guowen

    2015-08-01

    Personal cooling systems (PCS) have been developed to mitigate the impact of severe heat stress for humans working in hot environments. It is still a great challenge to develop PCSs that are portable, inexpensive, and effective. We studied the performance of a new hybrid PCS incorporating both ventilation fans and phase change materials (PCMs). The cooling efficiency of the newly developed PCS was investigated on a sweating manikin in two hot conditions: hot humid (HH, 34°C, 75% RH) and hot dry (HD, 34°C, 28% RH). Four test scenarios were selected: fans off with no PCMs (i.e., Fan-off, the CONTROL), fans on with no PCMs (i.e., Fan-on), fans off with fully solidified PCMs (i.e., PCM+Fan-off), and fans on with fully solidified PCMs (i.e., PCM+Fan-on). It was found that the addition of PCMs provided a 54∼78min cooling in HH condition. In contrast, the PCMs only offered a 19-39min cooling in HD condition. In both conditions, the ventilation fans greatly enhanced the evaporative heat loss compared with Fan-off. The hybrid PCS (i.e., PCM+Fan-on) provided a continuous cooling effect during the three-hour test and the average cooling rate for the whole body was around 111 and 315W in HH and HD conditions, respectively. Overall, the new hybrid PCS may be an effective means of ameliorating symptoms of heat stress in both hot-humid and hot-dry environments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. WRAP module 1 DMS/PCS interface definition document

    International Nuclear Information System (INIS)

    Weidert, J.R.

    1994-01-01

    This document has been developed to define the computer software interfaces between Waste Receiving ampersand Processing Module 1 (WRAP 1) computer systems. The interfaces include those data interfaces which exist between the Plant Control System (PCS) and Data Management System (DMS), between the DMS and Non-Destructive Assay (NDA) equipment, and between the DMS and Boxed Waste Assay System (BWAS) equipment. In addition to the data interfaces between the various WRAP computer systems; there are also a number of control functions between WRAP 1 equipment. These control function interfaces have been specified in WRAP Construction specification 13462 and the associated equipment specifications. The PCS vendor has been listed in the equipment specifications as the responsible party for establishing the final control system interface between the PCS and Non-Destructive Examination (NDE) Equipment, the PCS and Non-Destructive Assay (NDA) Equipment, and the PCS and BWAS equipment. The primary interface requirements between these systems are addressed in Specification Sections 13462, 13532, 13533, 13026, 13537, and 13538. Additional requirements may be found in other specification sections such as the Automatic Stacker Retriever System (AS/RS) Technical Specification 14520 and the WRAP 1 Data Management System Software Requirements Specification

  5. PCs The Missing Manual

    CERN Document Server

    Karp, David

    2005-01-01

    Your vacuum comes with one. Even your blender comes with one. But your PC--something that costs a whole lot more and is likely to be used daily and for tasks of far greater importance and complexity--doesn't come with a printed manual. Thankfully, that's not a problem any longer: PCs: The Missing Manual explains everything you need to know about PCs, both inside and out, and how to keep them running smoothly and working the way you want them to work. A complete PC manual for both beginners and power users, PCs: The Missing Manual has something for everyone. PC novices will appreciate the una

  6. PCs in the factory

    CERN Document Server

    2013-01-01

    Please note this is a short discount publication.PCs have become as essential to the factory environment as they are to the office environment. This in-depth report examines how specially adapted PCs and peripherals are being established in Factory Process Control and Reporting. The report covers: * Hardware and Software* Typical Applications* Implementation Issues* Case Studies and Real Applications

  7. PCS a code system for generating production cross section libraries

    International Nuclear Information System (INIS)

    Cox, L.J.

    1997-01-01

    This document outlines the use of the PCS Code System. It summarizes the execution process for generating FORMAT2000 production cross section files from FORMAT2000 reaction cross section files. It also describes the process of assembling the ASCII versions of the high energy production files made from ENDL and Mark Chadwick's calculations. Descriptions of the function of each code along with its input and output and use are given. This document is under construction. Please submit entries, suggestions, questions, and corrections to (ljc at sign llnl.gov) 3 tabs

  8. The evolution and impact of PCS technology

    Science.gov (United States)

    Lawson, John R.

    1994-09-01

    In today's mobile society, communications services that focus on location (wired) are increasingly inadequate. But services that center around the individual (wireless) are being developed to serve society in a way that only recently could consumers have imagined. People-oriented communications tools will make life simpler and more productive. The essence of this concept is captured in a family of wireless services and devices that allow the user to communicate independent of location--Personal Communications Services, known as PCS. First generation PCS devices such a pagers and cellular phones were the instruments of the first wireless revolution, but they will soon be forced to relinquish the spotlight to the new generation of PCS and what should be a dazzling variety of individualized advanced telecommunications services and devices. Within the next two years, these new PCS models, recently described as 'the most exciting development in telecommunications since the breakup of AT&T,' should hit the marketplace, changing the way we communicate and, in turn, the way we live. This paper explores the status and likely development of PCS generally, including 'new PCS.'

  9. Proposal for the award of blanket contracts for the supply of Intel-based desktop PCs, display monitors and portable PCs

    CERN Document Server

    2000-01-01

    This document concerns the award of blanket contracts for the supply of the three following categories of equipment for the period 2001-2004: a) desktop PCs (complete PC systems but without display monitors), b) display monitors (conventional CRTs or flat screen LCDs) and c) portable PCs (also called notebooks or laptops). Following a market survey carried out among 41 firms in fourteen Member States, an invitation to tender (IT-2692/IT) was sent on 19 May 2000 to 12 firms and three consortia, each consisting of two firms, in five Member States. By the closing date, CERN had received seven tenders, all from the Swiss subsidiaries of the firms and consortia. The Finance Committee is invited to agree to the negotiation of - blanket contracts with VOBIS (CH), ELONEX (CH) and FUJITSU-SIEMENS (CH), the three lowest bidders complying with the specification, for the supply of Desktop PCs; - blanket contracts with VOBIS (CH), SYNOPTIC (CH) and ELONEX (CH), the three lowest bidders offering display monitors manufactur...

  10. Make Projects Small Form Factor PCs

    CERN Document Server

    Wessels, Duane

    2006-01-01

    Shoebox sized and smaller, small-form-factor PCs can pack as much computing muscle as a full-sized desktop computer. They consumer less power, have few or no moving parts, and are very quiet. Whether you plan to use one as a standalone PC or want to embed it in your next hacking project, a small-form-factor PC can be a lot of fun to build. Make Projects: Small Form Factor PCs is the only book available that shows you how to build small-form-factor PCs -- from kits and from scratch -- that are more interesting and more personalized than what a full-sized PC can give you. Included in the book

  11. Use case driven approach to develop simulation model for PCS of APR1400 simulator

    International Nuclear Information System (INIS)

    Dong Wook, Kim; Hong Soo, Kim; Hyeon Tae, Kang; Byung Hwan, Bae

    2006-01-01

    The full-scope simulator is being developed to evaluate specific design feature and to support the iterative design and validation in the Man-Machine Interface System (MMIS) design of Advanced Power Reactor (APR) 1400. The simulator consists of process model, control logic model, and MMI for the APR1400 as well as the Power Control System (PCS). In this paper, a use case driven approach is proposed to develop a simulation model for PCS. In this approach, a system is considered from the point of view of its users. User's view of the system is based on interactions with the system and the resultant responses. In use case driven approach, we initially consider the system as a black box and look at its interactions with the users. From these interactions, use cases of the system are identified. Then the system is modeled using these use cases as functions. Lower levels expand the functionalities of each of these use cases. Hence, starting from the topmost level view of the system, we proceeded down to the lowest level (the internal view of the system). The model of the system thus developed is use case driven. This paper will introduce the functionality of the PCS simulation model, including a requirement analysis based on use case and the validation result of development of PCS model. The PCS simulation model using use case will be first used during the full-scope simulator development for nuclear power plant and will be supplied to Shin-Kori 3 and 4 plant. The use case based simulation model development can be useful for the design and implementation of simulation models. (authors)

  12. Study on operation of a research reactor during one PCS pump failure accident

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kyoung Woo; Yoon, Hyu Ngi; Kim, Seong Hoon; Chi, Dae Young; Yoon, Juh Yeon [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    The Primary cooling system (PCS) of a research reactor is designed to provide adequate cooling to the reactor core with a reasonable margin during all operation modes. The PCS consists of pumps, heat exchangers, and all necessary interconnecting pipes, valves, and instruments. The number of pumps is determined from a safety and economic point of view. As the number of pump trains increase, the cost increases according to the increase in safety class equipment. However, it is impossible to install one pump for a PCS because a zero flow can instantaneously occur during a pump failure such as a pump seizure. Thus, a PCS frequently consists of two parallel 50% capacity pumps and heat exchangers. In addition, check valves are generally installed to prevent a reversal flow when multiple pumps are designed to operate. However, if a swing type check valve is used, it should be estimated whether the slam due to instantaneous closing of the valve affects the system vibration. To reduce the vibration by a slam phenomenon, additional equipment such as a damper will be installed in the valve. The purpose of the check valve in PCS is to prevent the flow path when a reverse flow occurs. The installation of additional equipment will make it difficult to perform this function. In this study, it is estimated whether the PCS can operate without check valves. First, a flow analysis using Flowmaster was compared and verified by the calculation employing a empirical correlation. Second, the simulation for a one pump failure accident was performed and analyzed.

  13. Study on operation of a research reactor during one PCS pump failure accident

    International Nuclear Information System (INIS)

    Seo, Kyoung Woo; Yoon, Hyu Ngi; Kim, Seong Hoon; Chi, Dae Young; Yoon, Juh Yeon

    2012-01-01

    The Primary cooling system (PCS) of a research reactor is designed to provide adequate cooling to the reactor core with a reasonable margin during all operation modes. The PCS consists of pumps, heat exchangers, and all necessary interconnecting pipes, valves, and instruments. The number of pumps is determined from a safety and economic point of view. As the number of pump trains increase, the cost increases according to the increase in safety class equipment. However, it is impossible to install one pump for a PCS because a zero flow can instantaneously occur during a pump failure such as a pump seizure. Thus, a PCS frequently consists of two parallel 50% capacity pumps and heat exchangers. In addition, check valves are generally installed to prevent a reversal flow when multiple pumps are designed to operate. However, if a swing type check valve is used, it should be estimated whether the slam due to instantaneous closing of the valve affects the system vibration. To reduce the vibration by a slam phenomenon, additional equipment such as a damper will be installed in the valve. The purpose of the check valve in PCS is to prevent the flow path when a reverse flow occurs. The installation of additional equipment will make it difficult to perform this function. In this study, it is estimated whether the PCS can operate without check valves. First, a flow analysis using Flowmaster was compared and verified by the calculation employing a empirical correlation. Second, the simulation for a one pump failure accident was performed and analyzed

  14. A simulation environment for ITER PCS development

    International Nuclear Information System (INIS)

    Walker, M.L.; Ambrosino, G.; De Tommasi, G.; Humphreys, D.A.; Mattei, M.; Neu, G.; Raupp, G.; Treutterer, W.; Winter, A.

    2014-01-01

    Highlights: • Describes task to develop simulation tool to aid development/testing of ITER PCS. • Requirements and use cases and preliminary architecture have been delivered. • Detailed design is now being developed. • Provides overview of use cases and requirements. • Provides overview of architecture and status of development. - Abstract: A simulation environment known as the Plasma Control System Simulation Platform (PCSSP), specifically designed to support development of the ITER Plasma Control System (PCS), is currently under construction by an international team encompassing a cross-section of expertise in simulation and exception handling for plasma control. The proposed design addresses the challenging requirements of supporting the PCS design. This paper provides an overview of the PCSSP project and a discussion of some of the major features of its design. Plasma control for the ITER tokamak will be significantly more challenging than for existing fusion devices. An order of magnitude greater performance (e.g. [1,2]) is needed for some types of control, which together with limited actuator authority, implies that optimized individual controllers and nonlinear saturation logic are required. At the same time, consequences of control failure are significantly more severe, which implies a conflicting requirement for robust control. It also implies a requirement for comprehensive and robust exception handling. Coordinated control of multiple competing objectives with significant interactions, together with many shared uses of actuators to control multiple variables, implies that highly integrated control logic and shared actuator management will be required. It remains a challenge for the integrated technologies to simultaneously address these multiple and often competing requirements to be demonstrated on existing fusion devices and adapted for ITER in time to support its operational schedule. We describe ways in which the PCSSP will help address

  15. Superior integrin activating capacity and higher adhesion to fibrinogen matrix in buffy coat-derived platelet concentrates (PCs) compared to PRP-PCs.

    Science.gov (United States)

    Beshkar, Pezhman; Hosseini, Ehteramolsadat; Ghasemzadeh, Mehran

    2018-02-01

    Regardless of different sources, methods or devices which are applied for preparation of therapeutic platelets, these products are generally isolated from whole blood by the sedimentation techniques which are based on PRP or buffy coat (BC) separation. As a general fact, platelet preparation and storage are also associated with some deleterious changes that known as platelet storage lesion (PSL). Although these alternations in platelet functional activity are aggravated during storage, whether technical issues within preparation can affect integrin activation and platelet adhesion to fibrinogen were investigated in this study. PRP- and BC-platelet concentrates (PCs) were subjected to flowcytometry analysis to examine the expression of platelet activation marker, P-selectin as well as active confirmation of the GPIIb/IIIa (α IIb β 3 ) on day 0, 1, 3 and 5 post-storage. Platelet adhesion to fibrinogen matrix was evaluated by fluorescence microscopy. Glucose concentration and LDH activity were also measured by colorimetric methods. The increasing P-selectin expression during storage was in a reverse correlation with PAC-1 binding (r = -0.67; p = .001). PRP-PCs showed the higher level of P-selectin expression than BC-PCs, whereas the levels of PAC-1 binding and platelet adhesion to fibrinogen matrix were significantly lower in PRP-PCs. Higher levels of active confirmation of the GPIIb/IIIa in BC-PCs were also associated with greater concentration of glucose in these products. We demonstrated the superior capacities of integrin activation and adhesion to fibrinogen for BC-PCs compared to those of PRP-PCs. These findings may provide more advantages for BC method of platelet preparation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Results from the Veterans Health Administration ICD-10-CM/PCS Coding Pilot Study.

    Science.gov (United States)

    Weems, Shelley; Heller, Pamela; Fenton, Susan H

    2015-01-01

    The Veterans Health Administration (VHA) of the US Department of Veterans Affairs has been preparing for the October 1, 2015, conversion to the International Classification of Diseases, Tenth Revision, Clinical Modification and Procedural Coding System (ICD-10-CM/PCS) for more than four years. The VHA's Office of Informatics and Analytics ICD-10 Program Management Office established an ICD-10 Learning Lab to explore expected operational challenges. This study was conducted to determine the effects of the classification system conversion on coding productivity. ICD codes are integral to VHA business processes and are used for purposes such as clinical studies, performance measurement, workload capture, cost determination, Veterans Equitable Resource Allocation (VERA) determination, morbidity and mortality classification, indexing of hospital records by disease and operations, data storage and retrieval, research purposes, and reimbursement. The data collection for this study occurred in multiple VHA sites across several months using standardized methods. It is commonly accepted that coding productivity will decrease with the implementation of ICD-10-CM/PCS. The findings of this study suggest that the decrease will be more significant for inpatient coding productivity (64.5 percent productivity decrease) than for ambulatory care coding productivity (6.7 percent productivity decrease). This study reveals the following important points regarding ICD-10-CM/PCS coding productivity: 1. Ambulatory care ICD-10-CM coding productivity is not expected to decrease as significantly as inpatient ICD-10-CM/PCS coding productivity. 2. Coder training and type of record (inpatient versus outpatient) affect coding productivity. 3. Inpatient coding productivity is decreased when a procedure requiring ICD-10-PCS coding is present. It is highly recommended that organizations perform their own analyses to determine the effects of ICD-10-CM/PCS implementation on coding productivity.

  17. An Enlisted Personnel Permanent Change of Station (PCS) Policy Analysis Model.

    Science.gov (United States)

    1996-08-15

    When the first Patriot system engaged, fired and destroyed the first Scud missile over Riyadh, the effectiveness of the system became legendary - and...simulation to a monorail system. After leaving the location processing, the simulation analyzes the PCS_CODE attribute of the entity. The entity is then

  18. User guide to power management for PCs and monitors

    Energy Technology Data Exchange (ETDEWEB)

    Nordman, B.; Piette, M.A.; Kinney, K.; Webber, C. [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technologies Div.

    1997-01-01

    Power management of personal computers (PCs) and monitors has the potential to save significant amounts of electricity as well as deliver other economic and environmental benefits. The Environmental Protection Agency`s ENERGY STAR{reg_sign} program has transformed the PC market so that equipment capable of power management is now widely available. However, previous studies have found that many Energy Star compliant computer systems are not accomplishing energy savings. The principal reasons for this are systems not being enabled for power management or a circumstance that prevents power management from operating. This guide is intended to provide information to computer support workers to increase the portion of systems that successfully power manage. The guide introduces power management concepts and the variety of benefits that power management can bring. It then explains how the parts of a computer system work together to enter and leave power management states. Several common computer system types are addressed, as well as the complications that networks bring to power management. Detailed instructions for checking and configuring several system types are provided, along with trouble shooting advice. The guide concludes with a discussion of how to purchase Energy Star compliant systems and future directions for power management of PCs and related equipment.

  19. Consistency of variables in PCS and JASTRO great area database

    International Nuclear Information System (INIS)

    Nishino, Tomohiro; Teshima, Teruki; Abe, Mitsuyuki

    1998-01-01

    To examine whether the Patterns of Care Study (PCS) reflects the data for the major areas in Japan, the consistency of variables in the PCS and in the major area database of the Japanese Society for Therapeutic Radiology and Oncology (JASTRO) were compared. Patients with esophageal or uterine cervical cancer were sampled from the PCS and JASTRO databases. From the JASTRO database, 147 patients with esophageal cancer and 95 patients with uterine cervical cancer were selected according to the eligibility criteria for the PCS. From the PCS, 455 esophageal and 432 uterine cervical cancer patients were surveyed. Six items for esophageal cancer and five items for uterine cervical cancer were selected for a comparative analysis of PCS and JASTRO databases. Esophageal cancer: Age (p=.0777), combination of radiation and surgery (p=.2136), and energy of the external beam (p=.6400) were consistent for PCS and JASTRO. However, the dose of the external beam for the non-surgery group showed inconsistency (p=.0467). Uterine cervical cancer: Age (p=.6301) and clinical stage (p=.8555) were consistent for the two sets of data. However, the energy of the external beam (p<.0001), dose rate of brachytherapy (p<.0001), and brachytherapy utilization by clinical stage (p<.0001) showed inconsistencies. It appears possible that the JASTRO major area database could not account for all patients' backgrounds and factors and that both surveys might have an imbalance in the stratification of institutions including differences in equipment and staffing patterns. (author)

  20. From Novice to Expert: Problem Solving in ICD-10-PCS Procedural Coding

    Science.gov (United States)

    Rousse, Justin Thomas

    2013-01-01

    The benefits of converting to ICD-10-CM/PCS have been well documented in recent years. One of the greatest challenges in the conversion, however, is how to train the workforce in the code sets. The International Classification of Diseases, Tenth Revision, Procedure Coding System (ICD-10-PCS) has been described as a language requiring higher-level reasoning skills because of the system's increased granularity. Training and problem-solving strategies required for correct procedural coding are unclear. The objective of this article is to propose that the acquisition of rule-based logic will need to be augmented with self-evaluative and critical thinking. Awareness of how this process works is helpful for established coders as well as for a new generation of coders who will master the complexities of the system. PMID:23861674

  1. An approach to effective UHF (S/L band) data communications for satellite Personal Communication Service (PCS)

    Science.gov (United States)

    Hayase, Joshua Y.

    1995-01-01

    Reliable signaling information transfer is fundamental in supporting the needs of data communication PCS via LMS (Land Mobile Service) SSs (satellite systems). The needs of the system designer can be satisfied only through the collection of media information that can be brought to bear on the pertinent design issues. We at ISI hope to continue our dialogue with fading media experts to address the unique data communications needs of PCS via LMS SSs.

  2. Pricing the property claim service (PCS) catastrophe insurance options using gamma distribution

    Science.gov (United States)

    Noviyanti, Lienda; Soleh, Achmad Zanbar; Setyanto, Gatot R.

    2017-03-01

    The catastrophic events like earthquakes, hurricanes or flooding are characteristics for some areas, a properly calculated annual premium would be closely as high as the loss insured. From an actuarial perspective, such events constitute the risk that are not insurable. On the other hand people living in such areas need protection. In order to securitize the catastrophe risk, futures or options based on a loss index could be considered. Chicago Board of Trade launched a new class of catastrophe insurance options based on new indices provided by Property Claim Services (PCS). The PCS-option is based on the Property Claim Service Index (PCS-Index). The index are used to determine and payout in writing index-based insurance derivatives. The objective of this paper is to price PCS Catastrophe Insurance Option based on PCS Catastrophe index. Gamma Distribution is used to estimate PCS Catastrophe index distribution.

  3. Thermogravimetric study of a Phase Change Slurry: Effect of variable conditions

    International Nuclear Information System (INIS)

    Giro-Paloma, J.; Valle-Zermeño, R. del; Fernández, A.I.; Chimenos, J.M.; Formosa, J.

    2016-01-01

    Highlights: • Dry or wet PCS present differences in their thermal behavior. • The optimum conditions of dry PCS were determined by TGA. • Type of atmosphere and heating rate were the variables under consideration. • T peak can be accurately determined at 1 °C·min −1 in N 2. • Fusion/latent heat can be best determined at 10 °C·min −1 . - Abstract: Microcapsules containing Phase Change Materials (MPCM) are widely used for passive systems in energy storage. When MPCM are mixed with a carrier fluid, Phase Change Slurries (PCS) are used for heat transfer fluids in active systems or heat transport systems. The thermal behavior of PCS can be measured as dry or wet basis, resulting in important differences in weight losses. This study explores the optimum conditions for analyzing the thermal behavior of dried PCS by thermogravimetric analysis (TGA) varying the parameter conditions for obtaining peak temperature and heat flow (latent heat). The factors that were taken into account were the atmosphere of study (air and nitrogen) and the heating rate (0.5, 1, 5, and 10 °C·min −1 ). The best conditions to determine peak temperature are at 1 °C·min −1 and in N 2 atmosphere, whereas the decomposition fusion/latent heat of the sample is improved at higher heating velocities towards 10 °C·min −1 .

  4. Workshop Engages PCs in Accelerator Controls

    International Nuclear Information System (INIS)

    Matthew Bickley

    2006-01-01

    To discuss the rapidly growing and changing use of personal computers (PCs) in accelerator control systems, 80 accelerator controls specialists from 26 institutions in North America, Europe and Asia attended the 6. International Workshop on Personal Computers and Particle Accelerator Controls, PCaPAC2006, held October 24-27 at Jefferson Lab in Newport News, Virginia. PCs have become increasingly applicable to the control of accelerators as their computing capacities have increased exponentially over the last 10 years. Capabilities that once required the power available only from expensive, small-market systems offered by DEC, Sun or IBM can now be obtained with commodity hardware offered by many vendors. The price/performance ratio presented by any standard PC makes a compelling case for using PC hardware in accelerator controls wherever possible. The PCaPAC meeting underscored the importance of collaborative control system development. Several talks focused on additions to three such systems, TINE, TANGO and EPICS. The diverse contributions to these toolkits, both in content and source, demonstrate the power of leveraged software development across a number of facilities. TINE originated in DESY's desire to give users a unified software bus above disparate underlying platforms. TINE discussions at PCaPAC centered on the toolkit's interface layers, including address redirection and integration with other control systems. TANGO has been a collaborative effort from its inception. Based on CORBA, this open-source controls toolkit is a registered project in the source forge system. The workshop TANGO presentation discussed contributions from four TANGO institutions, and mentioned a broad range of new tools, from user interface applications to code generators and database integration software. EPICS, which was started at LANL in the 1980s, includes contributions from dozens of institutions around the world. EPICS-related PCaPAC discussions included virtual machines at

  5. Introducing an electronic Palliative Care Summary (ePCS) in Scotland: patient, carer and professional perspectives.

    Science.gov (United States)

    Hall, Susan; Murchie, Peter; Campbell, Christine; Murray, Scott A

    2012-10-01

    An electronic Palliative Care Summary (ePCS) is currently being implemented throughout Scotland to provide out-of-hours (OOH) staff with up-to-date summaries of medical history, patient understanding and wishes, medications and decisions regarding treatment of patients requiring palliative care: automatic twice daily updates of information from GP records to a central electronic repository are available to OOH services. To identify key issues related to the introduction of ePCS from primary care and OOH staff, to identify facilitators and barriers to their use, to explore the experiences of patients and carers and to make recommendations for improvements. Twenty-two semi-structured interviews were carried out with a purposive sample of health professionals [practice nurses (3 interviews), GPs (12 interviews), a practice manager (1 interview) from practices using different computing software systems] and patients and/or carers (6 interviews for whom an ePCS had been completed). Interviews were digitally recorded, transcribed and analysed thematically. Patients and carers were reassured that OOH staff were informed about their current circumstances. OOH staff considered the ePCS allowed them to be better informed in decision making and in carrying out home visits. GPs viewed the introduction of ePCSs to have benefits for in-hours structures of care including advance care planning. No interviewee expressed concern about confidentiality. Barriers raised related to the introduction of new technology including unfamiliarity with the process, limited time and information technology skills. The ePCS has clear potential to improve patient care although several implementation issues and technical problems require to be addressed first to enable this. GPs and community nurses should identify more patients with malignant and non-malignant illnesses for completion of the ePCS.

  6. Comparison of neural network applications for channel assignment in cellular TDMA networks and dynamically sectored PCS networks

    Science.gov (United States)

    Hortos, William S.

    1997-04-01

    The use of artificial neural networks (NNs) to address the channel assignment problem (CAP) for cellular time-division multiple access and code-division multiple access networks has previously been investigated by this author and many others. The investigations to date have been based on a hexagonal cell structure established by omnidirectional antennas at the base stations. No account was taken of the use of spatial isolation enabled by directional antennas to reduce interference between mobiles. Any reduction in interference translates into increased capacity and consequently alters the performance of the NNs. Previous studies have sought to improve the performance of Hopfield- Tank network algorithms and self-organizing feature map algorithms applied primarily to static channel assignment (SCA) for cellular networks that handle uniformly distributed, stationary traffic in each cell for a single type of service. The resulting algorithms minimize energy functions representing interference constraint and ad hoc conditions that promote convergence to optimal solutions. While the structures of the derived neural network algorithms (NNAs) offer the potential advantages of inherent parallelism and adaptability to changing system conditions, this potential has yet to be fulfilled the CAP for emerging mobile networks. The next-generation communication infrastructures must accommodate dynamic operating conditions. Macrocell topologies are being refined to microcells and picocells that can be dynamically sectored by adaptively controlled, directional antennas and programmable transceivers. These networks must support the time-varying demands for personal communication services (PCS) that simultaneously carry voice, data and video and, thus, require new dynamic channel assignment (DCA) algorithms. This paper examines the impact of dynamic cell sectoring and geometric conditioning on NNAs developed for SCA in omnicell networks with stationary traffic to improve the metrics

  7. Mobile geographic information system solution for pavement condition surveys [summary].

    Science.gov (United States)

    2012-01-01

    The State Materials Office (SMO) of the Florida : Department of Transportation (FDOT) performs : annual Pavement Condition Surveys (PCS) of : the Departments extensive pavement network. : This work is performed by single-person crews in : inertial...

  8. Second-Order Harmonic Reduction Technique for Photovoltaic Power Conditioning Systems Using a Proportional-Resonant Controller

    Directory of Open Access Journals (Sweden)

    Hae-Gwang Jeong

    2013-01-01

    Full Text Available This paper proposes a second-order harmonic reduction technique using a proportional-resonant (PR controller for a photovoltaic (PV power conditioning system (PCS. In a grid-connected single-phase system, inverters create a second-order harmonic at twice the fundamental frequency. A ripple component unsettles the operating points of the PV array and deteriorates the operation of the maximum power point tracking (MPPT technique. The second-order harmonic component in PV PCS is analyzed using an equivalent circuit of the DC/DC converter and the DC/AC inverter. A new feed-forward compensation technique using a PR controller for ripple reduction is proposed. The proposed algorithm is advantageous in that additional devices are not required and complex calculations are unnecessary. Therefore, this method is cost-effective and simple to implement. The proposed feed-forward compensation technique is verified by simulation and experimental results.

  9. SiC Coating Process Development Using H-PCS in Supercritical CO2

    International Nuclear Information System (INIS)

    Park, Kwangheon; Jung, Wonyoung

    2013-01-01

    We tried SiC coating using supercritical fluids. Supercritical fluids are the substance exists over critical temperature and critical pressure. It is hard to expect that there would be a big change as single-solvent as the fluid is incompressible and the space between the molecules is almost steady. But the fluid which is being supercritical can bring a great change when it is changed its pressure near its critical point, showing its successive change in the density, viscosity, diffusion coefficient and the polarity. We have tested the 'H-PCS into SiC' coating experiment with supercritical CO 2 which has the high penetration, low viscosity as well as the high density and the high solubility that shows the property of the fluid. This experiment is for SiC coating using H-PCS in supercritical CO 2 . It shows the clear difference that the penetration of H-PCS into the SiC between dip coating method and using the supercritical CO 2 If we can make a metal cladding with SiC composites as a protective layer, the use of the cladding will be very broad and diverse. Inherent safe nuclear fuels can be possible that can stand under severe accident conditions. SiC is known to be one of a few materials that maintain very corrosion-resistant properties under tough corrosive environments. The metal cladding with SiC composites as a protective layer will be a high-tech product that can be used in many applications including chemical, material, and nuclear engineering and etc

  10. Mobile geographic information system (GIS) solution for pavement condition surveys.

    Science.gov (United States)

    2012-06-28

    This report discusses the design and implementation of a software-based solution that will improve the data collection processes during the Pavement Condition Surveys (PCS) conducted by the State Materials Office (SMO) of the Florida Department of Tr...

  11. PCs all-in-one desk reference for dummies

    CERN Document Server

    Chambers, Mark L

    2013-01-01

    Need the scoop on Windows Vista? How about Office 2007? Anything you need to know about using your PC can probably be found in PCs All-In-One Desk Reference for Dummies, 4th Edition. This handy guide is made up of eight convenient minibooks, so you can find what you need in a hurry. And in case you think you've seen it before, this fourth edition is fully updated for all the newest, coolest stuff. Want a guided tour of the Vista operating system and how it differs from XP? Check out minibook #2. Have you heard about Microsoft Works but aren't sure what it's about? Find out

  12. Using Linux PCs in DAQ applications

    CERN Document Server

    Ünel, G; Beck, H P; Cetin, S A; Conka, T; Crone, G J; Fernandes, A; Francis, D; Joosb, M; Lehmann, G; López, J; Mailov, A A; Mapelli, Livio P; Mornacchi, Giuseppe; Niculescu, M; Petersen, J; Tremblet, L J; Veneziano, Stefano; Wildish, T; Yasu, Y

    2000-01-01

    ATLAS Data Acquisition/Event Filter "-1" (DAQ/EF1) project provides the opportunity to explore the use of commodity hardware (PCs) and Open Source Software (Linux) in DAQ applications. In DAQ/EF-1 there is an element called the LDAQ which is responsible for providing local run-control, error-handling and reporting for a number of read- out modules in front end crates. This element is also responsible for providing event data for monitoring and for the interface with the global control and monitoring system (Back-End). We present the results of an evaluation of the Linux operating system made in the context of DAQ/EF-1 where there are no strong real-time requirements. We also report on our experience in implementing the LDAQ on a VMEbus based PC (the VMIVME-7587) and a desktop PC linked to VMEbus with a Bit3 interface both running Linux. We then present the problems encountered during the integration with VMEbus, the status of the LDAQ implementation and draw some conclusions on the use of Linux in DAQ applica...

  13. Exploring the use of tablet PCs in veterinary medical education: opportunity or obstacle?

    Science.gov (United States)

    Wang, Hong; Rush, Bonnie R; Wilkerson, Melinda; van der Merwe, Deon

    2014-01-01

    A tablet PC is a laptop computer with a touch screen and a digital pen or stylus that can be used for handwritten notes and drawings. The use of tablet PCs has been investigated in many disciplines such as engineering, mathematics, science, and education. The purpose of this article is to explore student and faculty attitudes toward and experiences with tablet PCs 6 years after the implementation of a tablet PC program in the College of Veterinary Medicine (CVM) at Kansas State University (K-State). This study reports that the use of tablet PCs has enhanced students' learning experiences through learner-interface interaction, learner-content interaction, learner-instructor interaction, and learner-learner interaction. This study also identifies digital distraction as the major negative experience with tablet PCs during class time. The tablet PC program provides CVM faculty the potential to pursue technology integration strategies that support expected learning outcomes and provides students the potential to develop self-monitoring and self-discipline skills that support learning with digital technologies.

  14. Cross-cultural adaptation and validation of the South African Pain Catastrophizing Scale (SA-PCS among patients with fibromyalgia

    Directory of Open Access Journals (Sweden)

    Morris Linzette D

    2012-11-01

    Full Text Available Abstract Background Pain catastrophization has recently been recognized as a barrier to the healthy development of physical functioning among chronic pain patients. Levels of pain catastrophization in chronic pain patients are commonly measured using the Pain Catastrophizing Scale (PCS. Objective To cross-culturally adapt and validate the South African PCS (SA-PCS among English-, Afrikaans- and Xhosa-speaking patients with fibromyalgia living in the Cape Metropole area, Western Cape, South Africa. Methods The original PCS was cross-culturally adapted in accordance with international standards to develop an English, Afrikaans and Xhosa version of the SA-PCS using a repeated measures study design. Psychometric testing included face/content validity, internal consistency (Cronbach’s alpha-α, test-retest reliability (intraclass coefficient correlations-ICC, sensitivity-to-change and cross-sectional convergent validity (by comparing the adapted SA-PCS to related constructs. Results The cross-culturally adapted English, Afrikaans and Xhosa SA-PCS showed good face and content validity, excellent internal consistency (with Chronbach’s α = 0.98, 0.98 and 0.97 for the English, Afrikaans and Xhosa SA-PCS, as a whole, respectively, excellent test-retest reliability (with ICC’s of 0.90, 0.91 and 0.89 for the English, Afrikaans and Xhosa SA-PCS, respectively; as well as satisfactory sensitivity-to-change (with a minimum detectable change of 8.8, 9.0 and 9.3 for the English, Afrikaans and Xhosa SA-PCS, respectively and cross-sectional convergent validity (when compared to pain severity as well as South African versions of the Tampa scale for Kinesiophobia and the revised Fibromyalgia Impact Questionnaire. Conclusion The SA-PCS can therefore be recommended as simple, efficient, valid and reliable tool which shows satisfactory sensitivity-to-change and cross-sectional convergent validity, for use among English, Afrikaans and Xhosa-speaking patients with

  15. FANTM: The First Article NIF Test Module for the Laser Power Conditioning System

    International Nuclear Information System (INIS)

    Hammon, Jud; Harjes, Henry C.; Moore, William B.S.; Smith, David L.; Wilson, J. Michael

    1999-01-01

    Designing and developing the 1.7 to 2. 1-MJ Power Conditioning System (PCS) that powers the flashlamps for the National Ignition Facility (NIF), currently being constructed at Lawrence Livermore National Labs (LLNL), is one of several responsibilities assumed by Sandia National Labs (SNL) in support of the NIF Project. The test facility that has evolved over the last three years to satisfy the project requirements is called FANTM. It was built at SNL and has operated for about 17,000 shots to demonstrate component performance expectations over the lifetime of NIF. A few modules similar to the one shown in Fig. 1 will be used initially in the amplifier test phase of the project. The final till NIF system will require 192 of them (48 in each of four capacitor bays). This paper briefly summarizes the final design of the FANTM facility and compares its performance with the predictions of circuit simulations for both normal operation and fault-mode response. Applying both the measured and modeled power pulse waveforms as input to a physics-based, semi-empirical amplifier gain code indicates that the 20-capacitor PCS can satisfy the NIF requirement for an average gain coefficient of 5.00 %/cm and can exceed 5.20%/cm with 24 capacitors

  16. 77 FR 32975 - AHRQ Workgroups on ICD-10-CM/PCS Conversion of Quality Indicators (QIs)

    Science.gov (United States)

    2012-06-04

    ... on ICD-10-CM/PCS Conversion of Quality Indicators (QIs) AGENCY: Agency for Healthcare Research and... workgroups, to be convened by AHRQ's contractor, on ICD-10-CM/PCS conversion of the AHRQ Quality Indicators..., please visit the AHRQ Web site at http://www.QUALITYindicators.AHRQ.gov . Specifically, each Workgroup on...

  17. Design and Test of a Thermal Triggered Persistent Current System using High Temperature Superconducting Tapes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Keun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Kang, Hyoungku [Electro-Mechanical Research Institute, Hyundai Heavy Industries, Yongin (Korea, Republic of); Ahn, Min Cheol [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yang, Seong Eun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yoon, Yong Soo [Department of Electrical Engineering, Ansan College of Technology, 671 Choji-Dong, Danwon-Gu, Ansan, 425-792 (Korea, Republic of); Lee, Sang Jin [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Ko, Tae Kuk [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of)

    2006-06-01

    A superconducting magnet which is operated in persistent current mode in SMES, NMR, MRI and MAGLEV has many advantages such as high uniformity of magnetic field and reduced thermal loss. A high temperature superconducting (HTS) persistent current switch (PCS) system was designed and tested in this research. The HTS PCS was optimally designed using two different HTS tapes, second generation coated conductor (CC) HTS tape and Bi-2223 HTS tape by the finite element method (FEM) in thermal quench characteristic view. The CC tape is more prospective applicable wire in these days for its high n value and critical current independency from external magnetic field than Bi-2223 tape. Also a prototype PCS system using Bi-2223 tape was manufactured and tested. The PCS system consists of a PCS part, a heater which induces the PCS to quench, and a superconducting magnet. The test was performed in various conditions of transport current. An initial current decay appeared when the superconducting magnet was energized in a PCS system was analyzed. This paper would be foundation of HTS PCS researches.

  18. 47 CFR Appendix I to Subpart E of... - A Procedure for Calculating PCS Signal Levels at Microwave Receivers (Appendix E of the...

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false A Procedure for Calculating PCS Signal Levels...—A Procedure for Calculating PCS Signal Levels at Microwave Receivers (Appendix E of the Memorandum... receiver from the PCS operation. This appendix describes a procedure for computing this PCS level. In...

  19. Eleanor McElwee and the Formation of IEEE PCS

    Science.gov (United States)

    Malone, Edward A.

    2015-01-01

    This article examines the historical professional project that created the Institute of Radio Engineers' Professional Group on Engineering Writing an Speech (IRE PGEWS)--now called the Institute of Electrical and Electronics Engineers' Professional Communication Society (IEEE PCS)--and recounts the group's early history in detail. It also traces…

  20. PCs All-in-One For Dummies

    CERN Document Server

    Chambers, Mark L

    2010-01-01

    One-stop shopping for everything you need to know about PCs!. If you're a PC owner, you have a pretty good idea of just how much there is to discover about your PC, whether you use it for work or play. Comprised of eight minibooks, this All-in-One guide covers essential PC topics from soup through nuts, including the latest updates to PC hardware, Windows 7, the Internet, Office 2010, digital media, upgrading and troubleshooting, social media, and home networking. This new edition features expanded coverage of using popular social media such as Twitter, Facebook, WordPress, and blogging. Plus,

  1. Cloning expression and analysis of phytochelatin synthase (pcs) gene from Anabaena sp. PCC 7120 offering multiple stress tolerance in Escherichia coli

    International Nuclear Information System (INIS)

    Chaurasia, Neha; Mishra, Yogesh; Rai, Lal Chand

    2008-01-01

    Phytochelatin synthase (PCS) is involved in the synthesis of phytochelatins (PCs), plays role in heavy metal detoxification. The present study describes for first time the functional expression and characterization of pcs gene of Anabaena sp. PCC 7120 in Escherichia coli in terms of offering protection against heat, salt, carbofuron (pesticide), cadmium, copper, and UV-B stress. The involvement of pcs gene in tolerance to above abiotic stresses was investigated by cloning of pcs gene in expression vector pGEX-5X-2 and its transformation in E. coli BL21 (DE3). The E. coli cells transformed with pGEX-5X-pcs showed better growth than control cells (pGEX-5X-2) under temperature (47 deg. C), NaCl (6% w/v), carbofuron (0.025 mg ml -1 ), CdCl 2 (4 mM), CuCl 2 (1 mM), and UV-B (10 min) exposure. The enhanced expression of pcs gene revealed by RT-PCR analysis under above stresses at different time intervals further advocates its role in tolerance against above abiotic stresses

  2. Fabrication of a Sludge-Conditioning System for processing legacy wastes from the Gunite and Associated Tanks

    International Nuclear Information System (INIS)

    Randolph, J.D.; Lewis, B.E.; Farmer, J.R.; Johnson, M.A.

    2000-01-01

    The Sludge Conditioning System (SCS) for the Gunite and Associated Tanks (GAATs) is designed to receive, monitor, characterize and process legacy waste materials from the South Tank Farm tanks in preparation for final transfer of the wastes to the Melton Valley Storage Tanks (MVSTs), which are located at Oak Ridge National Laboratory. The SCS includes (1) a Primary Conditioning System (PCS) Enclosure for sampling and particle size classification, (2) a Solids Monitoring Test Loop (SMTL) for slurry characterization, (3) a Waste Transfer Pump to retrieve and transfer waste materials from GAAT consolidation tank W-9 to the MVSTs, (4) a PulsAir Mixing System to provide mixing of consolidated sludges for ease of retrieval, and (5) the interconnecting piping and valving. This report presents the design, fabrication, cost, and fabrication schedule information for the SCS

  3. Dynamical system analysis of unstable flow phenomena in centrifugal blower

    Directory of Open Access Journals (Sweden)

    Garcia David

    2015-09-01

    Full Text Available Methods of dynamical system analysis were employed to analyze unsteady phenomena in a centrifugal blower. Pressure signals gathered at different control points were decomposed into their Principal Components (PCs by means of Singular Spectrum Analysis (SSA. Certain number of PCs was considered in the analysis based on their statistical correlation. Projection of the original signal onto its PCs allowed to draw the phase trajectory that clearly separated non-stable blower working conditions from its regular operation.

  4. Intra-operative Patient-Controlled Sedation (PCS:Propofol versus Midazolam Supplementation During Epidural Analgesia (Clinical and Hormonal Study

    Directory of Open Access Journals (Sweden)

    Hassan S Al-khayat

    2008-01-01

    Full Text Available This study was done on sixty adult males scheduled to have an epidural analgesia for elective inguinal hernia repair. The study was designed to compare propofol and midazolam with regard to their suitability for the patient-controlled sedation (PCS technique during epidural analgesia. Patients were divided into three equal groups and premedicated with 0.2mg.kg -1 oral midazolam. Group I (G1 served as control. Using PCS technique, the pump was programmed to deliver on demand a bolus dose of 0.5 mg.kg- 1 of propofol in Group II (G2 or 0.1mg.kg -1 midazolam in Group III(G3. Patient′s sedation status was assessed by sedation score, comfort scale and by psychometric testing. The total delivered dose of each tested drug was calculated. Serum concentrations of propfol and midazolam, plasma cortisol and free fatty acids were measured. Propofol and midazolam PCS technique produced excellent and easily controllable sedation. The dose needed to produce steady state sedation was 2.8±1.42 and 0.11±0.6 mg.kg -1 .h- 1 for propofol and midazolam respectively. Propofol was more suitable than midazolam for PCS because of its rapid onset, favorable recovery profile and low side effects. PCS proved to be a stress-free and acceptable technique.

  5. Waste receiving and processing plant control system; system design description

    Energy Technology Data Exchange (ETDEWEB)

    LANE, M.P.

    1999-02-24

    The Plant Control System (PCS) is a heterogeneous computer system composed of numerous sub-systems. The PCS represents every major computer system that is used to support operation of the Waste Receiving and Processing (WRAP) facility. This document, the System Design Description (PCS SDD), includes several chapters and appendices. Each chapter is devoted to a separate PCS sub-system. Typically, each chapter includes an overview description of the system, a list of associated documents related to operation of that system, and a detailed description of relevant system features. Each appendice provides configuration information for selected PCS sub-systems. The appendices are designed as separate sections to assist in maintaining this document due to frequent changes in system configurations. This document is intended to serve as the primary reference for configuration of PCS computer systems. The use of this document is further described in the WRAP System Configuration Management Plan, WMH-350, Section 4.1.

  6. Waste receiving and processing plant control system; system design description

    International Nuclear Information System (INIS)

    LANE, M.P.

    1999-01-01

    The Plant Control System (PCS) is a heterogeneous computer system composed of numerous sub-systems. The PCS represents every major computer system that is used to support operation of the Waste Receiving and Processing (WRAP) facility. This document, the System Design Description (PCS SDD), includes several chapters and appendices. Each chapter is devoted to a separate PCS sub-system. Typically, each chapter includes an overview description of the system, a list of associated documents related to operation of that system, and a detailed description of relevant system features. Each appendice provides configuration information for selected PCS sub-systems. The appendices are designed as separate sections to assist in maintaining this document due to frequent changes in system configurations. This document is intended to serve as the primary reference for configuration of PCS computer systems. The use of this document is further described in the WRAP System Configuration Management Plan, WMH-350, Section 4.1

  7. Using Tablet PCs for Active Learning: Learning from Others' Mistakes

    Science.gov (United States)

    Robson, Daphne; Kennedy, Dave

    2013-01-01

    Tablet PCs were used interactively in a Discrete Mathematics course in the first year of a Computing degree. The main benefit expected was an improvement in student engagement, but peer instruction was very evident and the ability to display many student answers led to very effective and immediate feedback, particularly when incorrect answers were…

  8. 77 FR 40620 - AHRQ Workgroups on ICD-10-CM/PCS Conversion of Quality Indicators (QIs) - Extension Date for...

    Science.gov (United States)

    2012-07-10

    ... on ICD-10-CM/PCS Conversion of Quality Indicators (QIs) -- Extension Date for Nominations AGENCY... AHRQ QIs, please visit the AHRQ Web site at http://www.QUALITYindicators.AHRQ.gov . Specifically, each Workgroup on ICD-10-CM/PCS Conversion of Quality Indicators will consist of: --At least three individuals...

  9. Quantitative EEG Neurometric Analysis-Guided Neurofeedback Treatment in Postconcussion Syndrome (PCS): Forty Cases. How Is Neurometric Analysis Important for the Treatment of PCS and as a Biomarker?

    Science.gov (United States)

    Surmeli, Tanju; Eralp, Emin; Mustafazade, Ilham; Kos, Ismet Hadi; Özer, Gül Elif; Surmeli, Orkun H

    2017-05-01

    Postconcussion syndrome (PCS) has been used to describe a range of residual symptoms that persist 12 months or more after the injury, often despite a lack of evidence of brain abnormalities on magnetic resonance imaging and computed tomography scans. In this clinical case series, the efficacy of quantitative EEG-guided neurofeedback in 40 subjects diagnosed with PCS was investigated. Overall improvement was seen in all the primary (Symptom Assessment-45 Questionnaire, Clinical Global Impressions Scale, Hamilton Depression Scale) and secondary measures (Minnesota Multiphasic Personality Inventory, Test of Variables for Attention). The Neuroguide Traumatic Brain Index for the group also showed a decrease. Thirty-nine subjects were followed up long term with an average follow-up length of 3.1 years (CI = 2.7-3.3). All but 2 subjects were stable and were off medication. Overall neurofeedback treatment was shown to be effective in this group of subjects studied.

  10. Quantifying the potential export flows of used electronic products in Macau: a case study of PCs.

    Science.gov (United States)

    Yu, Danfeng; Song, Qingbin; Wang, Zhishi; Li, Jinhui; Duan, Huabo; Wang, Jinben; Wang, Chao; Wang, Xu

    2017-12-01

    The used electronic product (UEP) has attracted the worldwide attentions because part of e-waste may be exported from developed countries to developing countries in the name of UEP. On the basis of large foreign trade data of electronic products (e-products), this study adopted the trade data approach (TDA) to quantify the potential exports of UEP in Macau, taking a case study of personal computers (PCs). The results show that the desktop mainframes, LCD monitors, and CRT monitors have more low-unit-value trades with higher trade volumes in the past 10 years, while the laptop and tablet PCs, as the newer technologies, owned the higher ratios of the high-unit-value trades. During the period of 2005-2015, the total mean exports for used laptop and tablet PCs, desktop mainframes, and LCD monitors were approximately 18,592, 79,957, and 43,177 units, respectively, while the possible export volume of used CRT monitors was higher, up to 430,098 units in 2000-2010. Noticed that these potential export volumes could be the lower bound because not all used PCs may be shipped using the PC trade code. For all the four kinds of used PCs, the majority (61.6-98.82%) of the export volumes have gone to Hong Kong, followed by Mainland China and Taiwan. Since 2011, there was no CRT monitor export; however, the other kinds of used PC exports will still exist in Macau in the future. The outcomes are helpful to understand and manage the current export situations of used products in Macau, and can also provide a reference for other countries and regions.

  11. Architecture of WEST plasma control system

    International Nuclear Information System (INIS)

    Ravenel, N.; Nouailletas, R.; Barana, O.; Brémond, S.; Moreau, P.; Guillerminet, B.; Balme, S.; Allegretti, L.; Mannori, S.

    2014-01-01

    To operate advanced plasma scenario (long pulse with high stored energy) in present and future tokamak devices under safe operation conditions, the control requirements of the plasma control system (PCS) leads to the development of advanced feedback control and real time handling exceptions. To develop these controllers and these exceptions handling strategies, a project aiming at setting up a flight simulator has started at CEA in 2009. Now, the new WEST (W Environment in Steady-state Tokamak) project deals with modifying Tore Supra into an ITER-like divertor tokamak. This upgrade impacts a lot of systems including Tore Supra PCS and is the opportunity to improve the current PCS architecture to implement the previous works and to fulfill the needs of modern tokamak operation. This paper is dealing with the description of the architecture of WEST PCS. Firstly, the requirements will be presented including the needs of new concepts (segments configuration, alternative (or backup) scenario, …). Then, the conceptual design of the PCS will be described including the main components and their functions. The third part will be dedicated to the proposal RT framework and to the technologies that we have to implement to reach the requirements

  12. Neural signature of tDCS, tPCS and their combination: Comparing the effects on neural plasticity

    Science.gov (United States)

    Thibaut, Aurore; Russo, Cristina; Morales-Quezada, Leon; Hurtado-Puerto, Aura; Deitos, Alícia; Freedman, Steven; Carvalho, Sandra; Fregni, Felipe

    2017-01-01

    Transcranial pulsed current stimulation (tPCS) and transcranial direct current stimulation (tDCS) are two noninvasive neuromodulatory brain stimulation techniques whose effects on human brain and behavior have been studied individually. In the present study we aimed to quantify the effects of tDCS and tPCS, individually and in combination, on cortical activity, sensitivity and pain-related assessments in healthy individuals in order to understand their neurophysiological mechanisms and potential applications in clinical populations. A total of 48 healthy individuals participated in this randomized double blind sham controlled study. Participants were randomized to receive a single stimulation session of either: active or sham tPCS and active or sham tDCS. Quantitative electroencephalography (qEEG), sensitivity and pain assessments were used before and after each stimulation session. We observed that tPCS had a higher effect on power, as compared to tDCS, in several bandwidths on various cortical regions: the theta band in the parietal region (p = 0.021), the alpha band in the temporal (p = 0.009), parietal (p = 0.0063), and occipital (p tDCS significantly decreased power in the low beta bandwidth of the frontal (p = 0.0006), central (p = 0.0001), and occipital (p = 0.0003) regions, when compared to sham stimulation. Additionally, tDCS significantly increased power in high beta over the temporal (p = 0.0015) and parietal (p = 0.0007) regions, as compared to sham. We found no effect on sensitivity or pain-related assessments. We concluded that tPCS and tDCS have different neurophysiological mechanisms, elicit distinct signatures, and that the combination of the two leads to no effect or a decrease on qEEG power. Further studies are required to examine the effects of these techniques on clinical populations in which EEG signatures have been found altered. PMID:27765610

  13. Removal or transport of office furniture and PCs

    CERN Multimedia

    TS Department

    2008-01-01

    The TS/FM Group wishes to remind users that requests for the removal or transport of office furniture must be made using the EDH ‘Transport request’ form. Please select the "Removals" category from the drop-down menu to indicate the nature of the request. Requests for the transport of PCs from your office to Bldg. 513 or back must also be made using the EDH ‘Transport request’ form. In this case select the "PC transport" category from the drop-down menu. TS/FM Group Tel. 160239

  14. Are recommendations from carcinoma of the cervix Patterns of Care studies (PCS) in the United States of America (USA) applicable to centers in developing countries?

    International Nuclear Information System (INIS)

    Craighead, Peter S.; Smulian, Hubert G.; Groot, Henk J. de; Toit, Pierre F.M. du

    1997-01-01

    Purpose: To compare patient demographics, treatment resources, practice patterns, and outcome results for squamous cell carcinoma of the uterine cervix (SCC) between the 1978 and 1983 Patterns of Care studies (PCS) in the United States of America (USA) and a nonacademic center within a developing country. Methods and Materials: Patient details (race, age, stage, and number per year), treatment used, and treatment outcome were retrieved from the charts of the 1160 cases registered at this center with SCC of the cervix between 1976 and 1985. Demographic variables and Kaplan-Meier survival estimates were calculated and compared with results from published PCS reviews. Results: There is a significant difference in the racial group presentation of cervix cancer at this center compared with the PCS reviews (p < 0.005), and median ages are significantly lower at this center (t = p < 0.001). The proportion of patients with Stage III or more was significantly higher at this center than the PCS centers (24 vs. 47%, p < 0.001). There were also vast differences in facility resources. Fewer cases at this center underwent intracavitary insertions than at PCS centers. Mean Point A doses were significantly reduced for this center compared with the PCS reviews. Kaplan-Meier estimates were similar for Stage I and II in PCS centers and this center, but were inferior for this center in Stage III patients (p < 0.05 for OS and p < 0.01 for LC). Late morbidity rates were similar for both PCS centers and this center. Conclusion: PCS recommendations may be applicable to nonacademic centers within developing countries, if the latter use staging techniques that are consistent with the PCS staging guidelines

  15. Use of Tablet PCs to Enhance Instruction and Promote Group Collaboration in a Course to Prepare Future Mathematics Specialists

    Science.gov (United States)

    Ellington, Aimee J.; Wilson, Jill H.; Nugent, Jeffrey S.

    2011-01-01

    This article details the use of tablet PCs in a mathematics content course for future Mathematics Specialists. Instructors used tablet PCs instead of a traditional whiteboard to capture demonstration and discussion. Students were grouped for collaborative problem solving and exploration exercises. Each group was provided with a tablet PC for…

  16. Seismic attenuation in the African LLSVP estimated from PcS phases

    Science.gov (United States)

    Liu, Chujie; Grand, Stephen P.

    2018-05-01

    Seismic tomography models have revealed two broad regions in the lowermost mantle marked by ∼3% slower shear velocity than normal beneath the south central Pacific and southern Africa. These two regions are known as large-low-shear-velocity provinces (LLSVP). There is debate over whether the LLSVPs can be explained by purely thermal variations or whether they must be chemically distinct from normal mantle. Elastic properties alone, have been unable to distinguish the thermal from chemical interpretations. Anelastic structure, however, can help discriminate among models of the LLSVPs since intrinsic attenuation is more sensitive to temperature than to chemical variations. Here we estimate Qμ (the shear wave quality factor) in the African LLSVP using PcS waves generated from a Scotia Arc earthquake, recorded by broadband seismometers deployed in Southern Africa during the Kaapvaal experiment. The upward leg of the PcS waves sweeps from normal mantle into the African LLSVP across the array. We use the spectral ratio (SR) and instantaneous frequency matching (IFM) techniques to measure the differential attenuation (Δt*) between waves sampling the African LLSVP and the waves that sample normal lower mantle. Using both methods for estimating Δt* we find that PcS waves sampling the LLSVP are more attenuated than the waves that miss the LLSVP yielding a Δt* difference of more than 1 s. Using the Δt* measurements we estimate the average Qμ in the LLSVP to be about 110. Using a range of activation enthalpy (H*) estimates, we find an average temperature anomaly within the LLSVP ranging from +250 to +800 K. Our estimated temperature anomaly range overlaps previous isochemical geodynamic studies that explain the LLSVP as a purely thermal structure although the large uncertainties cannot rule out chemical variations as well.

  17. Safety evaluation for communication network software modifications of PCS in Ulchin NPP unit 3

    International Nuclear Information System (INIS)

    Ji, S. H.; Koh, J. S.; Kim, B. R.; Oh, S. H.

    1999-01-01

    On February 2, 1999, an incident occurred at the Ulchin Nuclear Power Plant Unit 3 which resulted in the corruption of data on Perform Net of Plant Control System. This incident was caused by the ASIC (Application Specific Integrated Circuit) chip on the Rehostable Module which is a part of Network Interface Module. Regarding this incident, we required that the utility should propose new algorithms to detect the hardware failure of ASIC chip and evaluated the appropriateness of network software modifications. As a result of this evaluation process, we required that the safety related interlock signals using data communication path be hardwired to make up for the vulnerability of the system architecture. In this paper, we will discuss the system architecture of PCS and fault analysis and evaluation findings

  18. Practical Considerations Informing Teachers' Technology Integration Decisions: The Case of Tablet PCs

    Science.gov (United States)

    Pareja Roblin, Natalie; Tondeur, Jo; Voogt, Joke; Bruggeman, Bram; Mathieu, Griet; van Braak, Johan

    2018-01-01

    The unique characteristics of tablet PCs promise important benefits for education. Yet, little is known about the rationale underlying teachers' decisions concerning their educational uses within the constraints of daily classroom practice. The current multiple case study investigated the practical considerations informing nine secondary school…

  19. Effects assessment of 10 functioning years on the main components of the molten salt PCS experimental facility of ENEA

    Science.gov (United States)

    Gaggioli, Walter; Di Ascenzi, Primo; Rinaldi, Luca; Tarquini, Pietro; Fabrizi, Fabrizio

    2016-05-01

    In the frame of the Solar Thermodynamic Laboratory, ENEA has improved CSP Parabolic Trough technologies by adopting new advanced solutions for linear tube receivers and by implementing a binary mixture of molten salt (60% NaNO3 and 40% KNO3) [1] as both heat transfer fluid and heat storage medium in solar field and in storage tanks, thus allowing the solar plants to operate at high temperatures up to 550°C. Further improvements have regarded parabolic mirror collectors, piping and process instrumentation. All the innovative components developed by ENEA, together with other standard parts of the plant, have been tested and qualified under actual solar operating conditions on the PCS experimental facility at the ENEA Casaccia Research Center in Rome (Italy). The PCS (Prova Collettori Solari, i.e. Test of Solar Collectors) facility is the main testing loop built by ENEA and it is unique in the world for what concerns the high operating temperature and the fluid used (mixture of molten salt). It consists in one line of parabolic trough collectors (test section of 100 m long life-size solar collectors) using, as heat transfer fluid, the aforesaid binary mixture of molten salt up to 10 bar, at high temperature in the range 270° and 550°C and a flow rate up to 6.5 kg/s. It has been working since early 2004 [2] till now; it consists in a unique closed loop, and it is totally instrumented. In this paper the effects of over ten years qualification tests on the pressurized tank will be presented, together with the characterization of the thermal losses of the piping of the molten salt circuit, and some observations performed on the PCS facility during its first ten years of operation.

  20. Isolation and sequence analysis of pCS36-4CPA, a small plasmid from Citrobacter sp. 36-4CPA.

    Science.gov (United States)

    Zharikova, Natalia V; Iasakov, Timur R; Bumazhkin, Boris K; Patutina, Ekaterina O; Zhurenko, Evgeniia I; Korobov, Vladislav V; Sagitova, Alina I; Kuznetsov, Boris B; Markusheva, Tatiana V

    2018-05-01

    A small plasmid designated pCS36-4CPA with a size of 5217 base pairs and G-C content of 50.74% was isolated from Citrobacter sp. 36-4CPA. The origin of replication ( ori ) of the plasmid was identified as a region of about 800 bp in length with an identity of 67.1% to the ColE1 plasmid at the nucleotide level. The replication region contained typical elements of ColE1-like plasmids: RNA I and RNA II with their corresponding -10 and -35 boxes, a single-strand initiation site ( ssi ), and a lagging-strand termination site ( terH ). As seen in other ColE1-like plasmids, pCS36-4CPA carried mobilisation machinery that include mobABCD genes but it did not possess the rom gene. Analysis of the multimer resolution site ( mrs ) was performed and XerC and XerD binding sites were identified. Also, the 70-nt transcript Rcd of pCS36-4CPA was predicted and similarity of the transcript's secondary structure with those of the ColE1-family was shown. The cargo module of pCS36-4CPA contained three open reading frames (ORFs). Two of them (ORF5 and ORF6) showed no significant homology to any known gene sequences but contained putative THAP DNA-binding (DBD) and type II restriction endonuclease Eco O109I domains. The seventh open reading frame (ORF7) encodes YhdJ-like DNA modification methylase. The region highly homologous to pCS36-4CPA was found in the Salmonella phage SE2 genome.

  1. InfiniBand-based real-time simulation of HVDC, STATCOM and SVC devices with commercial-off-the-shelf PCs and FPGAs

    Energy Technology Data Exchange (ETDEWEB)

    Dufour, C.; Abourida, S.; Belanger, J.; Lapointe, V. [OPAL-RT Technologies Inc., Montreal, PQ (Canada)

    2006-07-01

    Details of a real-time simulator for large power networks using commercial-off-the-shelf products and an RT-LAB platform were presented. The simulator was designed to realistically simulate bipolar high voltage DC (HVDC) networks transmission systems and to meet large grid simulation challenges. The system was also designed to cope with complex power grid design and validation tests as well as to interface with modern power electronic controllers and protection systems. The platform used Pentium, Xeon or Opteron based PCs and InfiniBand communication fabric for fast inter-PC communications. The real-time PC ran under well-known operating systems while the main control interface used Simulink software. Grid circuits were designed using an SPS interface using an ARTEMIS plug-in. Various model performances were reported. The results of several simulations suggested that InfiniBand communication was slower than shared-memory communication, while STATCOM timing was difficult to compare with the Opteron benchmarks. Results also suggested that XEON CPUs were slower than Opteron counterparts. Hardware-in-the-loop (HIL) testing was also performed with a prototype controller and with a real production controller. It was concluded that a communication time of 5 microseconds was obtained across the 2 PCs. The paper also discussed recent advances in HIL simulation and programming devices. 10 refs., 15 figs.

  2. 47 CFR 1.20007 - Additional assistance capability requirements for wireline, cellular, and PCS telecommunications...

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Additional assistance capability requirements for wireline, cellular, and PCS telecommunications carriers. 1.20007 Section 1.20007 Telecommunication... telecommunications carriers. (a) Definition—(1) Call-identifying information. Call identifying information means...

  3. Using Tablet PCs and Interactive Software in IC Design Courses to Improve Learning

    Science.gov (United States)

    Simoni, M.

    2011-01-01

    This paper describes an initial study of using tablet PCs and interactive course software in integrated circuit (IC) design courses. A rapidly growing community is demonstrating how this technology can improve learning and retention of material by facilitating interaction between faculty and students via cognitive exercises during lectures. While…

  4. Differential Expression Analysis by RNA-Seq Reveals Perturbations in the Platelet mRNA Transcriptome Triggered by Pathogen Reduction Systems

    OpenAIRE

    Osman, Abdimajid; Hitzler, Walter E.; Ameur, Adam; Provost, Patrick

    2015-01-01

    Platelet concentrates (PCs) are prepared at blood banks for transfusion to patients in certain clinical conditions associated with a low platelet count. To prevent transfusion-transmitted infections via PCs, different pathogen reduction (PR) systems have been developed that inactivate the nucleic acids of contaminating pathogens by chemical cross-linking, a mechanism that may also affect platelets' nucleic acids. We previously reported that treatment of stored platelets with the PR system Int...

  5. AN INVESTIGATION TO RESOLVE THE INTERACTION BETWEEN FUEL CELL, POWER CONDITIONING SYSTEM AND APPLICATION LOADS

    Energy Technology Data Exchange (ETDEWEB)

    Sudip K. Mazumder; Chuck McKintyre; Dan Herbison; Doug Nelson; Comas Haynes; Michael von Spakovsky; Joseph Hartvigsen; S. Elangovan

    2003-11-03

    nonlinear models of the SOFC stack subsystem (SOFCSS), the power-electronics subsystem (PES), and the BOPS. Such an approach leads to robust and comprehensive electrical, electrochemical, thermodynamic, kinetic, chemical, and geometric models of the SOFSS, PES and application loads, and BOPS. A comprehensive methodology to resolve interactions among SOFCSS, PES and application loads and to investigate the impacts of the fast- and slow-scale dynamics of the power-conditioning system (PCS) on the SOFCSS has been developed by this team. Parametric studies on SOFCSS have been performed and the effects of current ripple and load transients on SOFC material properties are investigated. These results are used to gain insights into the long-term performance and reliability of the SOFCSS. Based on this analysis, a novel, efficient, and reliable PES for SOFC has been developed. Impacts of SOFC PCS control techniques on the transient responses, flow parameters, and current densities have also been studied and a novel nonlinear hybrid controller for single/parallel DC-DC converter has been developed.

  6. Clusters of PCS for high-speed computation for modelling of the climate

    International Nuclear Information System (INIS)

    Pabon C, Jose Daniel; Eslava R, Jesus Antonio; Montoya G, Gerardo de Jesus

    2001-01-01

    In order to create high speed computing capability, the Program of Post grade in Meteorology of the Department of Geosciences, National University of Colombia installed a cluster of 8 PCs for parallel processing. This high-speed processing machine was tested with the Climate Community Model (CCM3). In this paper, the results related to the performance of this machine are presented

  7. Tablet PCs in a Paperless Classroom: Student and Teacher Perceptions on Screen Size

    Science.gov (United States)

    Runnels, Judith; Rutson-Griffiths, Arthur

    2013-01-01

    A paperless classroom, when all materials required to complete a class are available in an electronic form, has been shown to have positive impacts on student and teacher motivation, engagement, productivity, and efficiency. Recent trends suggest that of all of the technological tools available, tablet PCs can support many aspects of a paperless…

  8. Disk cloning program 'Dolly+' for system management of PC Linux cluster

    International Nuclear Information System (INIS)

    Atsushi Manabe

    2001-01-01

    The Dolly+ is a Linux application program to clone files and disk partition image from a PC to many others. By using several techniques such as logical ring connection, multi threading and pipelining, it could achieve high performance and scalability. For example, in typical condition, installations to a hundred PCs takes almost equivalent time for two PCs. Together with the Intel PXE and the RedHat kickstart, automatic and very fast system installation and upgrading could be performed

  9. Improvements in balance control in individuals with PCS detected following vestibular training: A case study.

    Science.gov (United States)

    Prangley, Alyssa; Aggerholm, Mathew; Cinelli, Michael

    2017-10-01

    Concussed individuals have been found to experience balance deficits in the anterior-posterior (AP) direction as indicated by greater Center of Pressure (COP) displacement and velocity. One possible reason for this change in balance control could be due to damage to the lateral vestibulospinal tract which sends signals to control posterior muscles, specifically ankle extensors leading to compensatory torques about the ankle. The purpose of the study was to quantify balance assessments in individuals experiencing persistent post-concussion symptoms (PCS) to determine balance control changes following a vestibular training intervention. Participants (N=6,>26days symptomatic), were tested during their first appointment with a registered physiotherapist (PT) and during each follow up appointment. Participants were prescribed balance, visual, and neck strengthening exercises by the PT that were to be completed daily between bi-weekly appointments. Balance assessments were quantified using a Nintendo Wii board to record ground reaction forces. Participants completed 4 balance assessments: 1) Romberg stance eyes open (REO); 2) Romberg stance eyes closed (REC); 3) single leg stance eyes open (SEO); and 4) single leg stance eyes closed (SEC). The balance assessments were conducted on both a firm and compliant surfaces. Significant improvements in balance control were noted in ML/AP displacement and velocity of COP for both SEC and Foam REC conditions, with additional improvements in AP velocity of COP for Foam REC and in ML displacement of COP during Foam SEC. Overall, findings indicate that objectively quantifying balance changes for individuals experiencing persistent PCS allows for a more sensitive measure of balance and detects changes unrecognizable to the naked eye. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Instructor Use of Tablet PCs in a College Pre-Calculus Course: Implementation & Assessment

    Science.gov (United States)

    Connelly Stockton, Julianna; Gregory, Peter

    2012-01-01

    A group of six math instructors used tablet PCs to teach their individual sections of a high enrollment gateway Pre-Calculus course in a diverse urban four-year college. Student performance in the experimental sections were compared to those in 31 other sections in terms of student retention, pass rates, and score on the department-wide…

  11. The web-based user interface for EAST plasma control system

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, R.R., E-mail: rrzhang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Anhui (China); Xiao, B.J. [Institute of Plasma Physics, Chinese Academy of Sciences, Anhui (China); School of Nuclear Science and Technology, University of Science and Technology of China, Anhui (China); Yuan, Q.P. [Institute of Plasma Physics, Chinese Academy of Sciences, Anhui (China); Yang, F. [Institute of Plasma Physics, Chinese Academy of Sciences, Anhui (China); Department of Computer Science, Anhui Medical University, Anhui (China); Zhang, Y. [Institute of Plasma Physics, Chinese Academy of Sciences, Anhui (China); Johnson, R.D.; Penaflor, B.G. [General Atomics, DIII-D National Fusion Facility, San Diego, CA (United States)

    2014-05-15

    The plasma control system (PCS) plays a vital role at EAST for fusion science experiments. Its software application consists of two main parts: an IDL graphical user interface for setting a large number of plasma parameters to specify each discharge, several programs for performing the real-time feedback control and managing the whole control system. The PCS user interface can be used from any X11 Windows client with privileged access to the PCS computer system. However, remote access to the PCS system via the IDL user interface becomes an extreme inconvenience due to the high network latency to draw or operate the interfaces. In order to realize lower latency for remote access to the PCS system, a web-based system has been developed for EAST recently. The setup data are retrieved from the PCS system and client-side JavaScript draws the interfaces into the user's browser. The user settings are also sent back to the PCS system for controlling discharges. These technologies allow the web-based user interface to be viewed by authorized users with a web browser and have it communicate with PCS server processes directly. It works together with the IDL interface and provides a new way to aid remote participation.

  12. The web-based user interface for EAST plasma control system

    International Nuclear Information System (INIS)

    Zhang, R.R.; Xiao, B.J.; Yuan, Q.P.; Yang, F.; Zhang, Y.; Johnson, R.D.; Penaflor, B.G.

    2014-01-01

    The plasma control system (PCS) plays a vital role at EAST for fusion science experiments. Its software application consists of two main parts: an IDL graphical user interface for setting a large number of plasma parameters to specify each discharge, several programs for performing the real-time feedback control and managing the whole control system. The PCS user interface can be used from any X11 Windows client with privileged access to the PCS computer system. However, remote access to the PCS system via the IDL user interface becomes an extreme inconvenience due to the high network latency to draw or operate the interfaces. In order to realize lower latency for remote access to the PCS system, a web-based system has been developed for EAST recently. The setup data are retrieved from the PCS system and client-side JavaScript draws the interfaces into the user's browser. The user settings are also sent back to the PCS system for controlling discharges. These technologies allow the web-based user interface to be viewed by authorized users with a web browser and have it communicate with PCS server processes directly. It works together with the IDL interface and provides a new way to aid remote participation

  13. An ORIGEN-2 update for PCs and mainframes

    International Nuclear Information System (INIS)

    Ludwig, S.B.

    1992-01-01

    This paper reports that an updated version of the ORIGEN2 code package has been prepared by Oak Ridge National Laboratory. ORIGEN2 is used extensively by the DOE office of Civilian Radioactive Waste Management (OCRWM) and its contractors to determine the characteristics of spent fuel and high-level radioactive waste due to irradiation, decay, and processing. Included in this update are revised ORIGEN2 cross-section libraries for standard- and extended-burnup PWRs and BWRs. This update also includes improvements to the ORIGEN2 computer code (designated as ORIGEN2, Version 2.1 8-1-91 release). This version of ORIGEN2 provides a single source code that may be executed on both mainframes and 80386 or 80486 PCs, effectively smashing the 640 KB barrier that limited previous PC implementations

  14. Using PWE/FE method to calculate the band structures of the semi-infinite beam-like PCs: Periodic in z-direction and finite in x–y plane

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Denghui, E-mail: qdhsd318@163.com; Shi, Zhiyu, E-mail: zyshi@nuaa.edu.cn

    2017-05-03

    This paper couples the plane wave expansion (PWE) and finite element (FE) methods to calculate the band structures of the semi-infinite beam-like phononic crystals (PCs) with the infinite periodicity in z-direction and finiteness in x–y plane. Explicit matrix formulations are developed for the calculation of band structures. In order to illustrate the applicability and accuracy of the proposed coupled plane wave expansion and finite element (PWE/FE) method to beam-like PCs, several examples are displayed. At first, PWE/FE method is applied to calculate the band structures of the Pb/rubber beam-like PCs with circular and rectangular cross sections, respectively. Then, it is used to calculate the band structures of steel/epoxy and steel/aluminum beam-like PCs with the same geometric parameters. Last, the band structure of the three-component beam-like PC is also calculated by the proposed method. Moreover, all the results calculated by PWE/FE method are compared with those calculated by finite element (FE) method, and the corresponding results are in good agreement. - Highlights: • The concept of the semi-infinite beam-like phononic crystals (PCs) is proposed. • The PWE/FE method is proposed and formulized to calculate the band structures of the semi-infinite beam-like PCs. • The strong applicability and high accuracy of PWE/FE method are verified.

  15. Theoretical and experimental evaluation of an indirect-fired GAX cycle cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, V.H.; Vidal, A. [Posgrado en Ingenieria, Energia, Universidad Nacional Autonoma de Mexico, Privada Xochicalco S/N, Apdo. Postal 34, 62580 Temixco Morelos (Mexico); Best, R.; Garcia-Valladares, O. [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Privada Xochicalco S/N, Apdo. Postal 34, 62580 Temixco Morelos (Mexico); Velazquez, N. [Instituto de Ingenieria, Universidad Autonoma de Baja California, Calle de la Normal S/N, Insurgentes Este, 21280 Mexicali, BC (Mexico)

    2008-06-15

    A theoretical and experimental evaluation of an indirect-fired GAX-Prototype Cooling System (GAX-PCS), using ammonia-water as the working fluid, is presented. The GAX-PCS was designed for a cooling capacity of 10.6 kW (3 tons). A simulation model was developed, calibrated and validated with experimental values in order to predict the performance of the system outside the design parameters. Experimental results were obtained using thermal oil, at temperatures from 180 to 195 C, as heating source. An internal heat recovery in the system of {proportional_to}55% with respect to the total heat supplied in the generator was obtained. Also the performance of the GAX absorption system, integrated to a micro gas turbine (MGT) as a cogeneration system was simulated. Overall efficiencies for the cogeneration system from 29% to 49% were obtained for cooling loads from 5 kW to 20 kW, respectively. With the theoretical and experimental study of the proposed cycle, it is concluded that the GAX-PCS presents potential to compete technically in the Mexican air conditioning market. (author)

  16. Physics of the conceptual design of the ITER plasma control system

    Energy Technology Data Exchange (ETDEWEB)

    Snipes, J.A., E-mail: Joseph.Snipes@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Bremond, S. [CEA-IRFM, 13108 St Paul-lez-Durance (France); Campbell, D.J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Casper, T. [1166 Bordeaux St, Pleasanton, CA 94566 (United States); Douai, D. [CEA-IRFM, 13108 St Paul-lez-Durance (France); Gribov, Y. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Humphreys, D. [General Atomics, San Diego, CA 92186 (United States); Lister, J. [Association EURATOM-Confédération Suisse, Ecole Polytechnique Fédérale de Lausanne (EPFL), CRPP, Lausanne CH-1015 (Switzerland); Loarte, A.; Pitts, R. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Sugihara, M., E-mail: Sugihara_ma@yahoo.co.jp [Japan (Japan); Winter, A.; Zabeo, L. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France)

    2014-05-15

    Highlights: • ITER plasma control system conceptual design has been finalized. • ITER's plasma control system will evolve with the ITER research plan. • A sophisticated actuator sharing scheme is being developed to apply multiple coupled control actions simultaneously with a limited set of actuators. - Abstract: The ITER plasma control system (PCS) will play a central role in enabling the experimental program to attempt to sustain DT plasmas with Q = 10 for several hundred seconds and also support research toward the development of steady-state operation in ITER. The PCS is now in the final phase of its conceptual design. The PCS relies on about 45 diagnostic systems to assess real-time plasma conditions and about 20 actuator systems for overall control of ITER plasmas. It will integrate algorithms required for active control of a wide range of plasma parameters with sophisticated event forecasting and handling functions, which will enable appropriate transitions to be implemented, in real-time, in response to plasma evolution or actuator constraints. In specifying the PCS conceptual design, it is essential to define requirements related to all phases of plasma operation, ranging from early (non-active) H/He plasmas through high fusion gain inductive plasmas to fully non-inductive steady-state operation, to ensure that the PCS control functionality and architecture will be capable of satisfying the demands of the ITER research plan. The scope of the control functionality required of the PCS includes plasma equilibrium and density control commonly utilized in existing experiments, control of the plasma heat exhaust, control of a range of MHD instabilities (including mitigation of disruptions), and aspects such as control of the non-inductive current and the current profile required to maintain stable plasmas in steady-state scenarios. Control areas are often strongly coupled and the integrated control of the plasma to reach and sustain high plasma

  17. Physics of the conceptual design of the ITER plasma control system

    International Nuclear Information System (INIS)

    Snipes, J.A.; Bremond, S.; Campbell, D.J.; Casper, T.; Douai, D.; Gribov, Y.; Humphreys, D.; Lister, J.; Loarte, A.; Pitts, R.; Sugihara, M.; Winter, A.; Zabeo, L.

    2014-01-01

    Highlights: • ITER plasma control system conceptual design has been finalized. • ITER's plasma control system will evolve with the ITER research plan. • A sophisticated actuator sharing scheme is being developed to apply multiple coupled control actions simultaneously with a limited set of actuators. - Abstract: The ITER plasma control system (PCS) will play a central role in enabling the experimental program to attempt to sustain DT plasmas with Q = 10 for several hundred seconds and also support research toward the development of steady-state operation in ITER. The PCS is now in the final phase of its conceptual design. The PCS relies on about 45 diagnostic systems to assess real-time plasma conditions and about 20 actuator systems for overall control of ITER plasmas. It will integrate algorithms required for active control of a wide range of plasma parameters with sophisticated event forecasting and handling functions, which will enable appropriate transitions to be implemented, in real-time, in response to plasma evolution or actuator constraints. In specifying the PCS conceptual design, it is essential to define requirements related to all phases of plasma operation, ranging from early (non-active) H/He plasmas through high fusion gain inductive plasmas to fully non-inductive steady-state operation, to ensure that the PCS control functionality and architecture will be capable of satisfying the demands of the ITER research plan. The scope of the control functionality required of the PCS includes plasma equilibrium and density control commonly utilized in existing experiments, control of the plasma heat exhaust, control of a range of MHD instabilities (including mitigation of disruptions), and aspects such as control of the non-inductive current and the current profile required to maintain stable plasmas in steady-state scenarios. Control areas are often strongly coupled and the integrated control of the plasma to reach and sustain high plasma

  18. Design of improved fuel cell controller for distributed generation systems

    Energy Technology Data Exchange (ETDEWEB)

    Olsen Berenguer, F.A. [Instituto de Energia Electrica, Universidad Nacional de San Juan, Av. Libertador San Martin Oeste, 1109, J5400ARL San Juan (Argentina); Molina, M.G. [CONICET, Instituto de Energia Electrica, Universidad Nacional de San Juan, Av. Libertador San Martin Oeste, 1109, J5400ARL San Juan (Argentina)

    2010-06-15

    The world has been undergoing a deregulation process which allowed competition in the electricity generation sector. This situation is bringing the opportunity for electricity users to generate power by using small-scale generation systems with emerging technologies, allowing the development of distributed generation (DG). A fuel cell power plant (FCPP) is a distributed generation technology with a rapid development because it has promising characteristics, such as low pollutant emissions, silent operation, high efficiency and long lifetime because of its small number of moving parts. The power conditioning system (PCS) is the interface that allows the effective connection to the electric power system. With the appropriate topology of the PCS and its control system design, the FCPP unit is capable of simultaneously performing both instantaneous active and reactive power flow control. This paper describes the design and implementation of a novel high performance PCS of an FCPP and its controller, for applications in distributed generation systems. A full detailed model of the FCPP is derived and a new three-level control scheme is designed. The dynamic performance of the proposed system is validated by digital simulation in SimPowerSystems (SPS) of MATLAB/Simulink. (author)

  19. Information Technologies Pre-Service Teachers' Acceptance of Tablet PCs as an Innovative Learning Tool

    Science.gov (United States)

    Cuhadar, Cem

    2014-01-01

    The current study is aimed to determine if Turkish IT pre-service teachers' acceptance of tablet PCs is within the framework of the Technology Acceptance Model. The research was patterned as a phenomenological study which is among the qualitative research methods. Participants were eight pre-service teachers studying in Trakya University, Faculty…

  20. Designing Applications for Physics Learning: Facilitating High School Students' Conceptual Understanding by Using Tablet PCs

    Science.gov (United States)

    Wang, June-Yi; Wu, Hsin-Kai; Chien, Sung-Pei; Hwang, Fu-Kwun; Hsu, Ying-Shao

    2015-01-01

    So far relatively little research in education has explored the pedagogical and learning potentials of applications (Apps) on tablet PCs (TPCs). Drawing upon research on learning technologies and taking an embodied perspective, this study first identified educational functionalities of TPCs and generated guidelines to design educational Apps for…

  1. Public PCs: Log Out or Lose Out

    CERN Multimedia

    Computer Security Team

    2013-01-01

    Do you regularly use one of the public Windows or Linux terminals in the CERN library or in front of the Users' Office? Or do you often give presentations or run meetings, workshops or conferences? Did you recently attend a training session in the CERN Training Centre? If you answered at least once with “yes”, we have a plea for you: LOG OUT when done in order to protect your data!   You might recall that CERN considers that “Your Privacy is Paramount”. But this does not come for free. In the few past months, we have received several reports from vigilant people who have spotted open user sessions on public PCs at CERN. Those users simply forgot to log out once their work, training or meeting was over. Their session continued without them being present. Worse, with CERN using a central Single Sign-On (SSO) portal, their login credentials would allow a malicious person at CERN to use those credentials to access that user’s mailbox, DFS ...

  2. Meta-Analysis of the Associations of p-Cresyl Sulfate (PCS) and Indoxyl Sulfate (IS) with Cardiovascular Events and All-Cause Mortality in Patients with Chronic Renal Failure.

    Science.gov (United States)

    Lin, Cheng-Jui; Wu, Vincent; Wu, Pei-Chen; Wu, Chih-Jen

    2015-01-01

    Indoxyl sulfate (IS) and p-cresyl sulfate (PCS) are protein-bound uremic toxins that increase in the sera of patients with chronic kidney disease (CKD), and are not effectively removed by dialysis. The purpose of this meta-analysis was to investigate the relationships of PCS and IS with cardiovascular events and all-cause mortality in patients with CKD stage 3 and above. Medline, Cochrane, and EMBASE databases were searched until January 1, 2014 with combinations of the following keywords: chronic renal failure, end-stage kidney disease, uremic toxin, uremic retention, indoxyl sulfate, p-cresyl sulfate. Inclusion criteria were: 1) Patients with stage 1 to 5 CKD; 2) Prospective study; 3) Randomized controlled trial; 4) English language publication. The associations between serum levels of PCS and IS and the risks of all-cause mortality and cardiovascular events were the primary outcome measures. Of 155 articles initially identified, 10 prospective and one cross-sectional study with a total 1,572 patients were included. Free PCS was significantly associated with all-cause mortality among patients with chronic renal failure (pooled OR = 1.16, 95% CI = 1.03 to 1.30, P = 0.013). An elevated free IS level was also significantly associated with increased risk of all-cause mortality (pooled OR = 1.10, 95% CI = 1.03 to 1.17, P = 0.003). An elevated free PCS level was significantly associated with an increased risk of cardiovascular events among patients with chronic renal failure (pooled OR = 1.28, 95% CI = 1.10 to 1.50, P = 0.002), while free IS was not significantly associated with risk of cardiovascular events (pooled OR = 1.05, 95% CI = 0.98 to 1.13, P = 0.196). Elevated levels of PCS and IS are associated with increased mortality in patients with CKD, while PCS, but not IS, is associated with an increased risk of cardiovascular events.

  3. TALEN-mediated single-base-pair editing identification of an intergenic mutation upstream of BUB1B as causative of PCS (MVA) syndrome

    Science.gov (United States)

    Ochiai, Hiroshi; Miyamoto, Tatsuo; Kanai, Akinori; Hosoba, Kosuke; Sakuma, Tetsushi; Kudo, Yoshiki; Asami, Keiko; Ogawa, Atsushi; Watanabe, Akihiro; Kajii, Tadashi; Yamamoto, Takashi; Matsuura, Shinya

    2014-01-01

    Cancer-prone syndrome of premature chromatid separation with mosaic variegated aneuploidy [PCS (MVA) syndrome] is a rare autosomal recessive disorder characterized by constitutional aneuploidy and a high risk of childhood cancer. We previously reported monoallelic mutations in the BUB1B gene (encoding BUBR1) in seven Japanese families with the syndrome. No second mutation was found in the opposite allele of any of the families studied, although a conserved BUB1B haplotype and a decreased transcript were identified. To clarify the molecular pathology of the second allele, we extended our mutational search to a candidate region surrounding BUB1B. A unique single nucleotide substitution, G > A at ss802470619, was identified in an intergenic region 44 kb upstream of a BUB1B transcription start site, which cosegregated with the disorder. To examine whether this is the causal mutation, we designed a transcription activator-like effector nuclease–mediated two-step single-base pair editing strategy and biallelically introduced this substitution into cultured human cells. The cell clones showed reduced BUB1B transcripts, increased PCS frequency, and MVA, which are the hallmarks of the syndrome. We also encountered a case of a Japanese infant with PCS (MVA) syndrome carrying a homozygous single nucleotide substitution at ss802470619. These results suggested that the nucleotide substitution identified was the causal mutation of PCS (MVA) syndrome. PMID:24344301

  4. The renewed HT-7 plasma control system based on real-time Linux cluster

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Q.P., E-mail: qpyuan@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Xiao, B.J.; Zhang, R.R. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Walker, M.L.; Penaflor, B.G.; Piglowski, D.A.; Johnson, R.D. [General Atomics, DIII-D National Fusion Facility, San Diego, CA (United States)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer The hardware and software structure of the new HT-7 plasma control system (HT-7 PCS) is reported. Black-Right-Pointing-Pointer All original systems were integrated in the new HT-7 PCS. And the implementation details of the control algorithms are given in the paper. Black-Right-Pointing-Pointer Different from EAST PCS, the AC operation mode is realized in HT-7 PCS. Black-Right-Pointing-Pointer The experiment results are discussed. Good control performance has been obtained. - Abstract: In order to improve the synchronization, flexibility and expansibility of the plasma control on HT-7, a new plasma control system (HT-7 PCS) was constructed. The HT-7 PCS was based on a real-time Linux cluster with a well-defined, robust and flexible software infrastructure which was adapted from DIII-D PCS. In this paper, the hardware structure and system customization details for HT-7 PCS are reported. The plasma position and current control, plasma density control and off-normal event detection, which were realized in separated systems originally, have been integrated and implemented in such HT-7 PCS. All these control algorithms have been successfully validated in the last several HT-7 experiment campaigns. Good control performance has been achieved and the experiment results are discussed in the paper.

  5. iRadioactivity — Possibilities and Limitations for Using Smartphones and Tablet PCs as Radioactive Counters

    Science.gov (United States)

    Kuhn, Jochen; Molz, Alexander; Gröber, Sebastian; Frübis, Jan

    2014-09-01

    A study conducted in 2013 showed that about 70-80% of teens and young adults in the United States own a smartphone.1 Furthermore the number of tablet PC users in the United States will increase up to more than 80% by 2015.2 As a result, these devices have increasingly become everyday tools, particularly for the younger generation. In recent years, various articles have been published about the use of smartphones and tablet PCs as experimental tools especially in the physics classroom. This is possible because today's smartphones and tablet PCs are equipped with many sensors, which can be used to perform quantitative measurements of sound, acceleration, magnetic flux density, air pressure, light intensity, humidity, angular velocity, temperature, or position on Earth (GPS). While previous articles mainly present experiments on mechanics or acoustics, in which the acceleration sensor or the microphone is used (for a synopsis of different examples, see Ref. 3; for recent papers, see Refs.), in this article we focus on experiments for studying radioactivity using the camera sensor.

  6. Interprocess communication within the DIII-D plasma control system

    International Nuclear Information System (INIS)

    Piglowski, D.A.; Penaflor, B.G.; Ferron, J.R.

    1999-06-01

    The DIII-D tokamak fusion research experiment's real-time digital plasma control system (PCS) is a complex and ever evolving system. During a plasma experiment, it is tasked with some of the most crucial functions at DIII-D. Key responsibilities of the PCS involve sub-system control, data acquisition/storage, and user interface. To accomplish these functions, the PCS is broken down into individual components (both software and hardware), each capable of handling a specific duty set. Constant interaction between these components is necessary prior, during and after a standard plasma cycle. Complicating the matter even more is that some components, mostly those which deal with user interaction, may exist remotely, that is to say they are not part of the immediate hardware which makes up the bulk of the PCS. The four main objectives of this paper are to (1) present a brief outline of the PCS hardware/software and how they relate to each other; (2) present a brief overview of a standard DIII-D plasma cycle (a shot); (3) using three sets of PCS sub-systems, describe in more detail the communication processes; and (4) evaluate the benefits and drawbacks of said systems

  7. Hyperbaric Oxygen Therapy in the Treatment of Chronic Mild-Moderate Blast-Induced Traumatic Brain Injury Post-Concussion Syndrome (PCS) and Post Traumatic Stress Disorder (PTSD)

    Science.gov (United States)

    2017-10-01

    Post-Concussion Syndrome (PCS) and Post Traumatic Stress Disorder (PTSD) PRINCIPAL INVESTIGATOR: Paul G. Harch, M.D. CONTRACTING ORGANIZATION...Traumatic Brain Injury Post-Concussion Syndrome (PCS) and Post Traumatic Stress Disorder (PTSD) 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR...injury (TBI) and post-traumatic stress disorder (PTSD) affect 11-28% and 13-17%, respectively, of U.S. combat troops returning from Iraq and

  8. Using Tablet PCs in Social Work Practice Education

    Directory of Open Access Journals (Sweden)

    Diane M. Hodge

    2008-06-01

    Full Text Available Within social work practice courses, video recording has been used to record and evaluate the clinical practice skills of students. This process has been limited by labor-intensive, tapebased video equipment, non-digital means of organizing and assessing specific scenes and events within the video, and paper evaluation forms. As an interdisciplinary project, professors from professional disciplines (education, social work, and counseling worked with information technology students from computer science to design and develop Table PC-based One- Note EVAs (Extended Video Application that would provide a more effective way of evaluating clinical practice skills for professional program students. This case study presents how one interdisciplinary team was able to create an EVA for use with digital recordings of clinical practice skills so that these demonstrations could be recorded, organized, and evaluated more effectively. The issues of working through communication differences, design difficulties, and the additional steps toward implementation are explored. The lessons learned from working as an interdisciplinary team and the impact of Tablet PCs in social work practice courses is also presented.

  9. Design of simulated nuclear electronics laboratory experiments based on IAEA-TECDOC-530 on pcs

    International Nuclear Information System (INIS)

    Ghousia, S.F.; Nadeem, M.; Khaleeq, M.T.

    2002-05-01

    In this IAEA project, PK-11089 (Design of Simulated Nuclear Electronics Laboratory Experiments based on IAEA-TECDOC-530 on PCs), a software package consisting of Computer-Simulated Laboratory Experiments on Nuclear Electronics compatible with the IAEA-TECDOC-530 (Nuclear Electronics Laboratory Manual) has been developed in OrCAD 9.0 (an electronic circuit simulation software environment) as a self-training aid. The software process model employed in this project is the Feedback Waterfall model with some Rapid Application Model. The project work is completed in the five phases of the SDLC, (all of them have been fully completed) which includes the Requirement Definition, Phase, System and Software Design, Implementation and Unit testing, Integration and System-testing phase and the Operation and Maintenance phase. A total of 125 circuits are designed in 39 experiments from Power Supplies, Analog circuits, Digital circuits and Multi-channel analyzer sections. There is another set of schematic designs present in the package, which contains faulty circuits. This set is designed for the learners to exercise the troubleshooting. The integration and system-testing phase was carried out simultaneously. The Operation and Maintenance phase has been implemented by accomplishing it through some trainees and some undergraduate engineering students by allowing them to play with the software independently. (author)

  10. Tablet PCs in Elementary Education A Pilot Project at the Practice Primary School of the KPH at Campus Vienna/Krems

    Directory of Open Access Journals (Sweden)

    Anton Reiter

    2015-09-01

    Full Text Available Am Beginn des Schuljahrs 2011/2012 wurde eine Volksschulklasse der im 21. Wiener Gemeindebezirk gelegenen Praxisschule der katholischen Pädagogischen Hochschule Wien/Krems mit Tablet-PCs ausgestattet. Die Geräte wurden von der Institution und den Eltern finanziert und allen SchülerInnen einer dritten Klasse zur Verfügung gestellt. Evaluation und Dokumentation des Projekts wurde vom österreichische Ministerium für Unterricht und Frauen finanziert. Wie aktuelle internationale Studien zeigen, gewöhnen sich neunjährige SchülerInnen schnell an solche Geräte. Das war auch in der hier vorgelegten Studie zu beobachten. Die SchülerInnen waren sehr motiviert und haben verschiedene Anwendungen erprobt. Die Tablets wurden auch außerhalb des Klassenraums verwendet, was als wesentlicher Vorteil mobiler Computer gesehen werden kann. Tablet-PCs ermöglichen individuelles Lernen und können für kooperative, soziale und interaktive Lernformen während des Unterrichts und in der Freizeit verwendet werden. Als persönliche mobile Geräte katalysieren die Tablet-PCs selbstgesteuertes “just-in-time” Lernen. Alle SchülerInnen sollten daher im 21. Jahrhundert solche Geräte zur Verfügung haben. One class of the practice primary school at the church-affilated former pedagogical college (KPH at Campus Vienna/Krems located in the 21st district of the capital of Austria was equipped with Tablet PCs at the beginning of the school year 2011/2012. These devices for all students of a third class were financed by the institution and partly the parents. The Austrian Federal Ministry of Education and Women's Affairs funded the evaluation and documentation of this two-year project. As recent international studies on the use of tablets (mostly iPads in primary and secondary education confirm, also these nine years old kids quickly got familiar with the used Pearl Touchlet tablets. The pupils were highly motivated and tried out different applications. The tablets

  11. Fatigue analysis of HANARO primary cooling system piping

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo

    1998-05-01

    A main form of piping failure which occurring leak before break (LBB) is fatigue failure. The fatigue analysis of HANARO primary cooling system (PCS) piping was performed. The PCS piping had been designed in accordance with ASME Class 3 for service conditions. However fatigue analysis is not required in Class 3. In this study the quantitative fatigue analysis was carried out according to ASME Class 1. The highest stress points which have the largest possibility of ASME class 1. The highest stress points which have the largest possibility of the fatigue were determined from the piping stress analysis for each subsection piping. The fatigue analysis was performed for 3 highest stress points, i.e., branch connection, anchor point and butt welding joint. After calculating the peak stress intensity range the fatigue usage factors were evaluated considering operating cycles and S-N curve. The cumulative usage factors for 3 highest stress points were much less than 1. The results show that the possibility of fatigue failure for PCS piping subjected to thermal expansion and seismic loads is very small. The structural integrity of the HANARO PCS piping for fatigue failure was proved to apply the LBB. (author). 11 tabs., 6 figs

  12. Upgrade of a control system for the JAERI ERL-FEL

    International Nuclear Information System (INIS)

    Kikuzawa, Nobuhiro

    2004-01-01

    The accelerator control system used for the JAERI ERL-FEL is a PC-based distributed control system that has been in operation since 1992. Since an interface bus of the PCs is obsolete, interface boards for the PCs are difficult to obtain in recent years. Thus we have been developing the CAMAC controller with μITRON operating system to replace the old PCs connected with CAMAC. We will introduce a Java and CORBA environment in the new control system. The control system upgrade, including hardware upgrading and applications rewriting, is described in this paper. (author)

  13. Product Configuration Systems - Implications for Product Innovation and Development

    DEFF Research Database (Denmark)

    Edwards, Kasper; Pedersen, Jørgen Lindgaard

    2004-01-01

    configurations. However, costs are but one parameter on which firms compete and firms must continually innovate new and develop existing products. This paper presents original empirical insights on implementation and use of product configuration systems in a number of Danish industrial firms. The paper discusses...... the organisational changes associated with PCS and how this affects product innovation and development. The paper begins by introducing product configuration systems, which are then placed in context to the firm as a process technology which coordinate different processes: product development, order acquisition......Product Configuration Systems (PCS) is a step in the direction of mass customization in the sense that PCS allows a firm to significantly lower the unit cost of configuration. Thus PCS is a valuable technology for lowering operating costs while retaining a high number of possible product...

  14. A web-based 'patterns of care study' system for clinical radiation oncology in Korea: development, launching, and characteristics

    International Nuclear Information System (INIS)

    Kim, II Han; Chie, Eui Kyu; Oh, Do Hoon

    2003-01-01

    We report upon a web-based system for Patterns of Care Study (PCS) devised for Korean radiation oncology, This PCS was designed to establish standard tools for clinical quality assurance, to determine basic parameters for radiation oncology processes, to offer a solid system for cooperative clinical studies and a useful standard database for comparisons with other national databases. The system consisted of a main server with two back-ups in other locations. The program uses a Linux operating system and a MySQL database. Cancers with high frequencies in radiotherapy departments in Korea from 1998 to 1999 were chosen to have a developmental priority. The web-based clinical PCS system for radiotherapy in www.pcs.re.kr was developed in early 2003 for cancers of the breast, rectum, esophagus, larynx and lung, and for brain metastasis. The total number of PCS study items exceeded one thousand. Our PCS system features user-friendliness, double entry checking, data security, encryption, hard disc mirroring, double back-up, and statistical analysis. Alphanumeric data can be input as well as image data. In addition, programs were constructed for IRB submission, random sampling of data, and departmental structure. For the first time in the field of PCS, we have developed a web-based system and associated working programs. With this system, we can gather sample data in a short period and thus save, cost, effort and time. Data should be performed to validate input data. We propose that this system should be considered as a standard method for PCS or similar types of data collection systems

  15. Impact of thermal energy storage properties on solar dynamic space power conversion system mass

    Science.gov (United States)

    Juhasz, Albert J.; Coles-Hamilton, Carolyn E.; Lacy, Dovie E.

    1987-01-01

    A 16 parameter solar concentrator/heat receiver mass model is used in conjunction with Stirling and Brayton Power Conversion System (PCS) performance and mass computer codes to determine the effect of thermal energy storage (TES) material property changes on overall PCS mass as a function of steady state electrical power output. Included in the PCS mass model are component masses as a function of thermal power for: concentrator, heat receiver, heat exchangers (source unless integral with heat receiver, heat sink, regenerator), heat engine units with optional parallel redundancy, power conditioning and control (PC and C), PC and C radiator, main radiator, and structure. Critical TES properties are: melting temperature, heat of fusion, density of the liquid phase, and the ratio of solid-to-liquid density. Preliminary results indicate that even though overall system efficiency increases with TES melting temperature up to 1400 K for concentrator surface accuracies of 1 mrad or better, reductions in the overall system mass beyond that achievable with lithium fluoride (LiF) can be accomplished only if the heat of fusion is at least 800 kJ/kg and the liquid density is comparable to that of LiF (1800 kg/cu m).

  16. Development and implementation of product configuration systems - a change management perspective

    DEFF Research Database (Denmark)

    Møldrup, Morten; Møller, Niels

    2004-01-01

    Product configuration systems (PCS) are IT-based expert systems, which contain product information and knowledge and in turn provide the basis for automating the decision-making processes in the order acquisition phase. Thereby PCS support and streamline the efforts of an organisations sales force...... in translating customer demands into customized products within a bounded range of product variation. Supported by a PCS the sales representatives are empowered to configure products without having to consult experts about product specific dependencies. Although several research projects have been carried out...... within the field of PCS, these efforts have primarily been focused on technical aspects. Based on experiences gained from twelve case studies in the context of the PETO (*) project, this article therefore sets out to broaden the scope of the PCS field to embrace managerial and organizational aspects...

  17. New achievements in the EAST plasma control system

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Q.P., E-mail: qpyuan@ipp.ac.c [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Xiao, B.J. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Penaflor, B.G.; Piglowski, D.A. [General Atomics, DIII-D National Fusion Facility, San Diego, CA (United States); Liu, L.Z. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Johnson, R.D.; Walker, M.L.; Humphreys, D.A. [General Atomics, DIII-D National Fusion Facility, San Diego, CA (United States)

    2010-07-15

    In order to realize the low latency and distortion-free signal transmission between the plasma control system (PCS) and servo systems, the digital output structure configured with reflective memory board (RFM) was adopted in EAST PCS. And the enhanced performances are reported. Another achievement made in the latest EAST PCS was the implementation of density control algorithm, which controlled the line average density in either voltage or width modulation mode. The new integrated algorithm improved the precision of density calculation and control performance greatly. The details and experiment results are presented in this paper.

  18. Synbiotic functional drink from Jerusalem artichoke juice fermented by probiotic Lactobacillus plantarum PCS26.

    Science.gov (United States)

    Dimitrovski, Darko; Velickova, Elena; Dimitrovska, Maja; Langerholc, Tomaz; Winkelhausen, Eleonora

    2016-01-01

    A probiotic strain Lactobacillus plantarum PCS26 was used to ferment Jerusalem artichoke juice. Growth kinetics of the bacterial strain was followed during juice fermentation both in flask and in laboratory fermentor. Jerusalem artichoke showed to be an excellent source of nutrients for L. plantarum PCS26 growth. The culture grew very well reaching more than 10(10) cfu/ml in just 12 h. The pH changed from the initial 6.5 to 4.6 at the end of fermentation. The culture hydrolyzed fructooligosaccharides present in the Jerusalem artichoke juice, yielding fructose which was presumably consumed along with the malic acid as energy and carbon source. Lactic acid was the main metabolite produced in concentration of 4.6 g/L. Acetic and succinic acid were also identified. Sensory evaluation of the fermented Jerusalem artichoke juice and its mixtures with blueberry juice showed that the 50/50 % v/v mixture would be very well accepted by the consumers. Above 80 % of the panelists would buy this drink, and over 60 % were willing to pay more for it. Culture survivability in the fermented juices during storage at 4-7 °C was assayed by the Weibullian model. The product shelf-life was extended from 19.70 ± 0.50 days of pure Jerusalem artichoke juice to 35.7 ± 6.4 days of the mixture containing 30 % blueberry juice.

  19. An overview of control system for the ITER electron cyclotron system

    International Nuclear Information System (INIS)

    Purohit, D.; Bigelow, T.; Billava, D.; Bonicelli, T.; Caughman, J.; Darbos, C.; Denisov, G.; Gandini, F.; Gassmann, T.; Henderson, M.; Journeux, J.Y.; Kajiwara, K.; Kobayashi, N.; Nazare, C.; Oda, Y.; Omori, T.; Rao, S.L.; Rasmussen, D.; Ronden, D.; Saibene, G.

    2011-01-01

    The ITER electron cyclotron (EC) system having capability of up to 26 MW generated power at 170 GHz is being procured by 5 domestic agencies via 10 procurement arrangements. This implies diverse types of equipment and complex interface management. It also places a challenge on control system architecture to entertain the constraints of procurement slicing and meeting the overall functional requirement. The envisioned architecture is to use the local control units (supplied with each procurement) and a supervisory plant controller (by ITER). This offers a reliable control configuration for such delicate and complex EC plant system. The control system is envisioned to monitor the whole plant and perform automated tasks that are today performed via direct human intervention. For example, the automated gyrotron conditioning and active control of the EC plant to respond to requests from the plasma control system (PCS). This later aspect requires rapid shut down of the gyrotrons and power supplies, deviation of the actuators to direct the power from an equatorial to upper launcher and then restart of the power generation for rapid stabilization of the magneto hydrodynamic (MHD) instabilities that occur in high performance plasma operation. The plant controller will be designed for optimized performance with the PCS and the feedback control system used to actively control the power (with modulation capability up to 5 kHz) and launching direction for MHD stabilization.

  20. An ORIGEN2 update for PCs and mainframes

    International Nuclear Information System (INIS)

    Ludwig, S.B.

    1991-01-01

    The ORIGEN2 computer code was developed by Oak Ridge National Laboratory (ORNL) in the late 1970s and made available to users worldwide in 1980 through the Radiation Shielding Information Center (RSIC). The purpose of ORIGEN2 is to calculate the buildup, decay, and processing of radioactive materials. Since 1980, more than 500 users have acquired the ORIGEN2 code from RSIC. ORIGEN2 is often the starting point for many analyses involving the shielding, criticality, safety, performance assessment, accident analysis, risk assessment, and design of reactors, transportation casks, reprocessing plants, and waste disposal facilities. An updated version of the ORIGEN2 code package has been prepared by ORNL. This new version of the ORIGEN2 package (called ORIGEN2, Version 2.1 (8-1-91)) includes revised ORIGEN2 cross-section libraries for standard- and extended-burnup pressurized-water and boiling-water reactors (PWRs and BWRs). These libraries were used in the preparation of Revision 1 of the Characteristic Data Base (CDB). The ORIGEN2 code has also been revised to include numerous maintenance fixes and to consolidate various hardware versions into a single source code capable of execution of both 80386/80486 PCs as well as most mainframe computers; these improvements are part of Version 2.1. 6 refs., 2 tabs

  1. Transient behavior of ASTRID with a gas power conversion system

    Energy Technology Data Exchange (ETDEWEB)

    Bertrand, F., E-mail: frederic.bertrand@cea.fr; Mauger, G.; Bensalah, M.; Gauthé, P.

    2016-11-15

    Highlights: • CATHARE2 transient calculations have been performed for ASTRID with a gas PCS. • The behavior of the reactor is close for gas and for water PCS in case of LOOP. • The gas PCS enables to cool the core for at least 10 h for pressurized transients. • The depressurization of the PCS induces an over-cooling for breaches on low pressure pipes. • The spurious opening of a by-pass line of the turbomachine can be controlled without scram. - Abstract: The present article is dedicated to preliminary transient studies carried out for the analysis of the system overall behavior of the ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration) demonstrator developed in France by CEA and its industrial partners. ASTRID is foreseen to demonstrate the progress made in SFR technology at an industrial scale by qualifying innovative options, some of which still remain open in the areas requiring improvements, especially safety and operability. Among the innovative options, a gas power conversion systems (PCS) is envisaged. In this innovative PCS, the working gas is nitrogen whose flow rate delivers power to a turbine driving with the same shaft two compressors (low and high pressure) separated by an intercooler. The other part of the work delivered by the gas is used to drive the alternator that produces electricity. The main objective of such a PCS consists in avoiding physically the possibility of a sodium/water reaction with the secondary circuit but the impact of this PCS on the control of incidental and accidental transients has also been studied. The main purpose of the studies presented in the paper is to assess the dynamic behavior of ASTRID including a gas PCS with the CATHARE2 code. The first transient presented deals with a loss of off-site power and has been calculated for the gas PCS but also for a classical steam/water PCS for comparison purpose. Then typical transients of gas system have been investigated. Several families of

  2. Transient behavior of ASTRID with a gas power conversion system

    International Nuclear Information System (INIS)

    Bertrand, F.; Mauger, G.; Bensalah, M.; Gauthé, P.

    2016-01-01

    Highlights: • CATHARE2 transient calculations have been performed for ASTRID with a gas PCS. • The behavior of the reactor is close for gas and for water PCS in case of LOOP. • The gas PCS enables to cool the core for at least 10 h for pressurized transients. • The depressurization of the PCS induces an over-cooling for breaches on low pressure pipes. • The spurious opening of a by-pass line of the turbomachine can be controlled without scram. - Abstract: The present article is dedicated to preliminary transient studies carried out for the analysis of the system overall behavior of the ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration) demonstrator developed in France by CEA and its industrial partners. ASTRID is foreseen to demonstrate the progress made in SFR technology at an industrial scale by qualifying innovative options, some of which still remain open in the areas requiring improvements, especially safety and operability. Among the innovative options, a gas power conversion systems (PCS) is envisaged. In this innovative PCS, the working gas is nitrogen whose flow rate delivers power to a turbine driving with the same shaft two compressors (low and high pressure) separated by an intercooler. The other part of the work delivered by the gas is used to drive the alternator that produces electricity. The main objective of such a PCS consists in avoiding physically the possibility of a sodium/water reaction with the secondary circuit but the impact of this PCS on the control of incidental and accidental transients has also been studied. The main purpose of the studies presented in the paper is to assess the dynamic behavior of ASTRID including a gas PCS with the CATHARE2 code. The first transient presented deals with a loss of off-site power and has been calculated for the gas PCS but also for a classical steam/water PCS for comparison purpose. Then typical transients of gas system have been investigated. Several families of

  3. Application of Product Configuration Systems in Engineering Companies

    DEFF Research Database (Denmark)

    Kristjansdottir, Katrin

    Engineering companies increasingly face the challenge of delivering highly customized products where time, cost, and quality are critical factors. To provide customized products efficiently, a product configuration system (PCS) is commonly implemented. A PCS supports the product configuration...... process, which consists of activities that involve gathering requirements from customers and generating the required product-related specifications. The application of a PCS in the industry has revealed benefits that include shorter lead-times, improved quality of specifications and products, and lower...... overall cost of the product. However, many PCS projects do encounter failure. With an increased focus on customized and personalized products, there is a growing need for the automation of business processes. For this reason, a PCS is becoming an essential part of IT strategy in different industries...

  4. The documentation of product configuration systems: A framework and an IT solution

    DEFF Research Database (Denmark)

    Shafiee, Sara; Hvam, Lars; Haug, Anders

    2017-01-01

    for maintenance, further development, system quality and communication with domain experts. Product models are the main communication and documentation tools used in PCS projects. Recent studies have shown that up-to-date documentation for the PCS is often lacking due to the significant amount of work required...... system is proposed that is capable of retrieving knowledge from the PCS and thus generating the product model. Our framework and IT documentation system were developed and tested at a case company on five different projects. The results confirm that benefits can be achieved by using the proposed...

  5. Energetic and economic evaluation of solar thermal and photovoltaic cooling system in Cuban hotel

    International Nuclear Information System (INIS)

    Díaz Torres, Yamile; Valdivia Nodal, Yarelis; Castellanos Molina, Luis Miguel; Torres del Toro, Migdalia; Monteagudo Llanes, José

    2015-01-01

    The present paper discusses the energetic and economic feasibility of using two configurations of solar cooling in a Cuban Hotel. The air conditioning hybrid system schemes are: conventional system (Chiller) interconnected in parallel with a solar- powered absorption cooling system (SACS); and a photovoltaic cooling system (PCS). There were analyzed by methodologies and thermodynamic principles governing these technologies. The results show that their uses are alternatives for reducing energy consumption and environmental impact. (full text)

  6. Analysis on Single Point Vulnerabilities of Plant Control System

    International Nuclear Information System (INIS)

    Chi, Moon Goo; Lee, Eun Chan; Bae, Yeon Kyoung

    2011-01-01

    The Plant Control System (PCS) is a system that controls pumps, valves, dampers, etc. in nuclear power plants with an OPR-1000 design. When there is a failure or spurious actuation of the critical components in the PCS, it can result in unexpected plant trips or transients. From this viewpoint, single point vulnerabilities are evaluated in detail using failure mode effect analyses (FMEA) and fault tree analyses (FTA). This evaluation demonstrates that the PCS has many vulnerable components and the analysis results are provided for OPR-1000 plants for reliability improvements that can reduce their vulnerabilities

  7. Analysis on Single Point Vulnerabilities of Plant Control System

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Moon Goo; Lee, Eun Chan; Bae, Yeon Kyoung [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2011-08-15

    The Plant Control System (PCS) is a system that controls pumps, valves, dampers, etc. in nuclear power plants with an OPR-1000 design. When there is a failure or spurious actuation of the critical components in the PCS, it can result in unexpected plant trips or transients. From this viewpoint, single point vulnerabilities are evaluated in detail using failure mode effect analyses (FMEA) and fault tree analyses (FTA). This evaluation demonstrates that the PCS has many vulnerable components and the analysis results are provided for OPR-1000 plants for reliability improvements that can reduce their vulnerabilities.

  8. Resource Allocation in a Frequency Hopping PCS1900/GSM/DCS1800 Type of Network

    DEFF Research Database (Denmark)

    Nielsen, Thomas Toftegaard; Wigard, Jeroen; Michaelsen, Per-Henrik

    1999-01-01

    Resource allocation in a frequency hopping network is even more problematic than in a traditional network. The combined effect from all serving frequencies has to be considered directly in the allocation process. An algorithm doing this for a PCS1900/GSM/DCS1800 type of network is presented. The ....... A graphical visualisation tool has been developed as well. This tool uses a network quality measure tightly linked to the FER rather than the traditional C/I or BER. Using these statistics an increase in network quality is shown...

  9. NSTX-U Control System Upgrades

    International Nuclear Information System (INIS)

    Erickson, K.G.; Gates, D.A.; Gerhardt, S.P.; Lawson, J.E.; Mozulay, R.; Sichta, P.; Tchilinguirian, G.J.

    2014-01-01

    The National Spherical Tokamak Experiment (NSTX) is undergoing a wealth of upgrades (NSTX-U). These upgrades, especially including an elongated pulse length, require broad changes to the control system that has served NSTX well. A new fiber serial Front Panel Data Port input and output (I/O) stream will supersede the aging copper parallel version. Driver support for the new I/O and cyber security concerns require updating the operating system from Redhat Enterprise Linux (RHEL) v4 to RedHawk (based on RHEL) v6. While the basic control system continues to use the General Atomics Plasma Control System (GA PCS), the effort to forward port the entire software package to run under 64-bit Linux instead of 32-bit Linux included PCS modifications subsequently shared with GA and other PCS users. Software updates focused on three key areas: (1) code modernization through coding standards (C99/C11), (2) code portability and maintainability through use of the GA PCS code generator, and (3) support of 64-bit platforms. Central to the control system upgrade is the use of a complete real time (RT) Linux platform provided by Concurrent Computer Corporation, consisting of a computer (iHawk), an operating system and drivers (RedHawk), and RT tools (NightStar). Strong vendor support coupled with an extensive RT toolset influenced this decision. The new real-time Linux platform, I/O, and software engineering will foster enhanced capability and performance for NSTX-U plasma control

  10. NSTX-U Control System Upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, K.G., E-mail: kerickso@pppl.gov; Gates, D.A.; Gerhardt, S.P.; Lawson, J.E.; Mozulay, R.; Sichta, P.; Tchilinguirian, G.J.

    2014-06-15

    The National Spherical Tokamak Experiment (NSTX) is undergoing a wealth of upgrades (NSTX-U). These upgrades, especially including an elongated pulse length, require broad changes to the control system that has served NSTX well. A new fiber serial Front Panel Data Port input and output (I/O) stream will supersede the aging copper parallel version. Driver support for the new I/O and cyber security concerns require updating the operating system from Redhat Enterprise Linux (RHEL) v4 to RedHawk (based on RHEL) v6. While the basic control system continues to use the General Atomics Plasma Control System (GA PCS), the effort to forward port the entire software package to run under 64-bit Linux instead of 32-bit Linux included PCS modifications subsequently shared with GA and other PCS users. Software updates focused on three key areas: (1) code modernization through coding standards (C99/C11), (2) code portability and maintainability through use of the GA PCS code generator, and (3) support of 64-bit platforms. Central to the control system upgrade is the use of a complete real time (RT) Linux platform provided by Concurrent Computer Corporation, consisting of a computer (iHawk), an operating system and drivers (RedHawk), and RT tools (NightStar). Strong vendor support coupled with an extensive RT toolset influenced this decision. The new real-time Linux platform, I/O, and software engineering will foster enhanced capability and performance for NSTX-U plasma control.

  11. The Linux based distributed data acquisition system for the ISTRA+ experiment

    International Nuclear Information System (INIS)

    Filin, A.; Inyakin, A.; Novikov, V.; Obraztsov, V.; Smirnov, N.; Vlassov, E.; Yuschenko, O.

    2001-01-01

    The DAQ hardware of the ISTRA+ experiment consists of the VME system crate that contains two PCI-VME bridges interfacing two PCs with VME, external interrupts receiver, the readout controller for dedicated front-end electronics, the readout controller buffer memory module, the VME-CAMAC interface, and additional control modules. The DAQ computing consist of 6 PCs running the Linux operating system and linked into LAN. The first PC serves the external interrupts and acquires the data from front-end electronic. The second one is the slow control computer. The remaining PCs host the monitoring and data analysis software. The Linux based DAQ software provides the external interrupts processing, the data acquisition, recording, and distribution between monitoring and data analysis tasks running at DAQ PCs. The monitoring programs are based on two packages for data visualization: home-written one and the ROOT system. MySQL is used as a DAQ database

  12. [Quality of buffy-coat-derived platelet concentrates prepared using automated system terumo automated centrifuge and separator integration (TACSI)].

    Science.gov (United States)

    Zebrowska, Agnieszka; Lipska, Alina; Rogowska, Anna; Bujno, Magdalena; Nedzi, Marta; Radziwon, Piotr

    2011-03-01

    Platelet recovery, and viability, and function is strongly dependent on the method of the preparation of platelet concentrate (PC). The glucose consumption, decrease of pH, release of alpha granules during storage in platelet concentrate impair their clinical effectiveness. To compare of the quality of buffy-coat-derieved platelet concentrates prepared using automatic system terumo automated centrifuge and separator integration (TACSI) and stored over 7 days. PCs were prepared from buffy coats using manual method (group I), or automatic system TACSI (group II). Fifteen PCs prepared from the 5 buffy coats each were stored over 7 days in 22-24 degrees C and tested. Samples were taken from the PCs container on days 1 and 7. The following laboratory tests were performed: number of platelets, platelets derived microparticles, CD62P expression, platelet adhesion, pH, glucose, lactate dehydrogenase activity. We have observed higher expression of CD62P in PCs prepared using manual method compared to the PCs produced automatically Platelet recovery was significantly higher in PCs prepared using automatic systems compare to manual method. Compared to manual methods, automatic system for preparation of buffy coats, is more efficient and enable production of platelets concentrates of higher quality.

  13. Condition Indicators for Gearbox Condition Monitoring Systems

    Directory of Open Access Journals (Sweden)

    P. Večeř

    2005-01-01

    Full Text Available Condition monitoring systems for manual transmissions based on vibration diagnostics are widely applied in industry. The systems deal with various condition indicators, most of which are focused on a specific type of gearbox fault. Frequently used condition indicators (CIs are described in this paper. The ability of a selected condition indicator to describe the degree of gearing wear was tested using vibration signals acquired during durability testing of manual transmission with helical gears. 

  14. Current status and prospect of plasma control system for steady-state operation on QUEST

    International Nuclear Information System (INIS)

    Hasegawa, Makoto; Nakamura, Kazuo; Zushi, Hideki; Hanada, Kazuaki; Fujisawa, Akihide; Tokunaga, Kazutoshi; Idei, Hiroshi; Nagashima, Yoshihiko; Kawasaki, Shoji; Nakashima, Hisatoshi; Higashijima, Aki

    2016-01-01

    Highlights: • Overall configuration of plasma control system on QUEST are presented. • Multi core system and reflective memories are used for the real-time control. • Hall sensors are used for the identification of plasma current and its position. • Repetitive gas fueling with the feed-back control of Hα signal is implemented. - Abstract: The plasma control system (PCS) of QUEST is developed according to the progress of QUEST project. Since one of the critical goals of the project is to achieve the steady-state operation with high temperature vacuum vessel wall, the PCS is also required to have the capability to control the plasma for a long period. For the increase of the loads to processing power of the PCS, the PCS is decentralized with the use of reflective memories (RFMs). The PCS controls the plasma edge position with the real-time identification of plasma current and its position. This identification is done with not only flux loops but also hall sensors. The gas fueling method by piezo valve with monitoring the Hα signal filtered by a digital low-pass filter are proposed and suitable for the steady-state operation on QUEST. The present status and prospect of the PCS are presented with recent topics.

  15. Current status and prospect of plasma control system for steady-state operation on QUEST

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Makoto, E-mail: hasegawa@triam.kyushu-u.ac.jp; Nakamura, Kazuo; Zushi, Hideki; Hanada, Kazuaki; Fujisawa, Akihide; Tokunaga, Kazutoshi; Idei, Hiroshi; Nagashima, Yoshihiko; Kawasaki, Shoji; Nakashima, Hisatoshi; Higashijima, Aki

    2016-11-15

    Highlights: • Overall configuration of plasma control system on QUEST are presented. • Multi core system and reflective memories are used for the real-time control. • Hall sensors are used for the identification of plasma current and its position. • Repetitive gas fueling with the feed-back control of Hα signal is implemented. - Abstract: The plasma control system (PCS) of QUEST is developed according to the progress of QUEST project. Since one of the critical goals of the project is to achieve the steady-state operation with high temperature vacuum vessel wall, the PCS is also required to have the capability to control the plasma for a long period. For the increase of the loads to processing power of the PCS, the PCS is decentralized with the use of reflective memories (RFMs). The PCS controls the plasma edge position with the real-time identification of plasma current and its position. This identification is done with not only flux loops but also hall sensors. The gas fueling method by piezo valve with monitoring the Hα signal filtered by a digital low-pass filter are proposed and suitable for the steady-state operation on QUEST. The present status and prospect of the PCS are presented with recent topics.

  16. How to Identify Possible Applications of Product Configuration Systems in Engineer-to-Order Companies

    DEFF Research Database (Denmark)

    Kristjansdottir, Katrin; Shafiee, Sara; Hvam, Lars

    2017-01-01

    -toorder (ETO) companies that support gradual implementation of PCS due to large product variety and, several times, higher complexity of products and processes. The overall PCS process can thereby be broken down, and the risk minimised. This paper provides a three-step framework to identify different......Product configuration systems (PCS) play an essential role when providing customised and engineered products efficiently. Literature in the field describes numerous strategies to develop PCS but neglects to identify different application areas. This topic is particularly important for engineer...

  17. High-Quality Learning Environments for Engineering Design: Using Tablet PCs and Guidelines from Research on How People Learn

    OpenAIRE

    Enrique Palou; Lourdes Gazca; Juan Antonio Díaz García; José Andrés Rojas Lobato; Luis Geraldo Guerrero Ojeda; José Francisco Tamborero Arnal; María Teresa Jiménez Munguía; Aurelio López-Malo; Juan Manuel Garibay

    2012-01-01

    A team of several faculty members and graduate students at Universidad de las Amricas Puebla is improving engineering design teaching and learning by creating richer learning environments that promote an interactive classroom while integrating formative assessment into classroom practices by means of Tablet PCs and associated technologies. Learning environments that are knowledge-, learner-, community-, and assessment-centered as highlighted by the How People Learn framework, have been devel...

  18. Conceptual Modelling for Product Configuration Systems

    DEFF Research Database (Denmark)

    Shafiee, Sara

    Individual customization of goods and processes in different industries leads to complexity due to a growing mix of products both regarding characteristics of products and support services. In order to eliminate complexity and challenges in product/process customizing, smart IT systems called...... Product Configuration Systems (PCS), have been proposed as the solution both by researchers and practitioners and various benefits are mentioned from utilizing PCSs. Based on the latest literature, there are challenges reported in all phases of PCS projects including planning, development......, and documentation. Moreover, the challenges become more serious when it involves complicated products/processes in engineer-to-order (ETO) companies. The purpose of this thesis is to contribute to the existing knowledge of managing PCS projects by proposing frameworks and tools to address some of the main...

  19. Plasma FITC-dextran exchange between the primary and secondary circulatory systems in the Atlantic cod, Gadus Morhua

    DEFF Research Database (Denmark)

    Fischer, Claes; Steffensen, John Fleng

    2008-01-01

    Fluorescein isothiocyanate dextran (FITC-dextran) exchange between the primary (PCS) and secondary (SCS) circulatory systems in the Atlantic cod, Gadus morhua (Linnaeus, 1752), were studied using 20-kDa (n = 4) and 500-kDa (n = 4) FITC-dextran. In order to give a qualitative perspective...... of the general connection between the PCS and SCS, distribution of plasma-borne tracers (FITC-dextran) in the PCS and SCS were examined. In this study, a total of eight cod were cannulated in the ventral aorta (PCS) and dorsal cutaneous vessel (SCS), for investigation of FITC-dextran disappearance in the PCS...... and its subsequent appearance in the SCS. FITC-dextran of both sizes was found to be in equilibrium between the PCS and SCS in less than 20 min. This indicates a profound connection between the PCS and SCS in the Atlantic cod, and rapid mixing of tracers between the PCS and SCS. The destination...

  20. Plasma control system for 'Day-One' operation of KSTAR tokamak

    International Nuclear Information System (INIS)

    Hahn, Sang-hee; Walker, M.L.; Kim, Kukhee; Ahn, H.S.; Penaflor, B.G.; Piglowski, D.A.; Johnson, R.D.; Choi, Jaehoon; Lee, Dong-keun; Kim, Jayhyun; Yoon, S.W.; Seo, Seong-Heon; Kim, H.T.; Kim, K.P.; Lee, T.G.; Park, M.K.; Bak, J.G.; Lee, S.G.; Nam, Y.U.; Eidietis, N.W.

    2009-01-01

    A complete plasma control system (PCS) has been developed for KSTAR's first plasma campaign as a collaborative project with the DIII-D team. The KSTAR real time plasma control system is based on a conceptual design by Jhang and Choi [Hogun Jhang, I.S. Choi, Fusion Engineering and Design 73 (2005) 35-49] and consists of a fast real-time computer/communication cluster and software derived from the GA-PCS [Penaflor, B.G., et.al., Fusion Engineering and Design, 83 (2) (2008) 176]. The system has been used for simulation testing, poloidal field (PF) coil power supply commissioning and first plasma control. The seven sets of up-down symmetric, superconducting PF coil/power supply systems have been successfully tested. Reflective memory (RFM) is utilized as the primary actuator/PCS real-time communication layer and PCS synchronization with KSTAR timing system and slower control devices is achieved through an EPICS implementation. Consistent feedback loop times of 100 microseconds has been achieved during PF coil power supply testing and first plasma commissioning. Here we present the 'Day-One' plasma control system in its final form for the first plasma experimental campaign of KSTAR and describe how the system has been utilized during magnet commissioning and plasma startup experiments.

  1. Millisecond timing on PCs and Macs.

    Science.gov (United States)

    MacInnes, W J; Taylor, T L

    2001-05-01

    A real-time, object-oriented solution for displaying stimuli on Windows 95/98, MacOS and Linux platforms is presented. The program, written in C++, utilizes a special-purpose window class (GLWindow), OpenGL, and 32-bit graphics acceleration; it avoids display timing uncertainty by substituting the new window class for the default window code for each system. We report the outcome of tests for real-time capability across PC and Mac platforms running a variety of operating systems. The test program, which can be used as a shell for programming real-time experiments and testing specific processors, is available at http://www.cs.dal.ca/~macinnwj. We propose to provide researchers with a sense of the usefulness of our program, highlight the ability of many multitasking environments to achieve real time, as well as caution users about systems that may not achieve real time, even under optimal conditions.

  2. Bus Accessing Performance Evaluation for Plant Control System

    International Nuclear Information System (INIS)

    Chung, Yang Mook

    2005-01-01

    The PCS system with 44 communication masters(CM) which process more than 30000 input and output signals, designed and manufactured by HF Contorols Corporation, is applied to UCN No. 5,6 nuclear power plant for the first time. In the process of system operation, the numerous problems have been issued and investigated and fixed so far. To share a understanding for digital communication system, UCN PCS communication methods are described herein through comparisons between the different priority techniques as well as the results of performance tests

  3. Remote mobile communication in safety support system

    International Nuclear Information System (INIS)

    Inagaki, Kanji; Kobayashi, Hiroyuki; Hatanaka, Takahiro; Sakuma, Akira; Fukumoto, Akira; Ikeda, Jun

    1999-01-01

    Safety Support System (SSS) is a computerized operator support system for nuclear power plants, which is now under development. The concept of SSS covers 1) earlier detection of failure symptom and prediction of its influence to the plant operation, 2) improved transparency and robustness of plant control systems, 3) advanced human-machine interface and communication. The authors have been working on the third concept and proposed a remote mobile communication system called Plant Communication System (PCS). PCS aims to realize convenient communication between main control room and other areas such as plant local areas and site offices, using Personal Handyphone System (PHS) and wireless LAN (Local Area Network). PCS can transmit not only data but also graphic displays and dynamic video displays between the main control room and plant local areas. MPEG4 (Moving Picture Experts Group 4) technology is utilized in video data compression and decompression. The authors have developed the special multiplexing unit that connects PHS Cell Stations (CSs) and exiting coaxial cables. Voice recognition and announcement capability is also realized in the system, which enables verbal retrieval of information in the computer systems in the main control room from local areas. (author)

  4. Study on the power control system for NPP power unit with the WWER-440 reactor

    International Nuclear Information System (INIS)

    Aleksandrova, N.D.; Naumov, A.V.

    1981-01-01

    Results of model investigations into basic version of the power control systems (PCS) conformably to the WWER-440 NPP power unit are stated. Transient processes in the power unit system when being two PCS versions during perturbations of different parameters: unit power, vapour pressure or position of control rods have been simulated. Investigations into the different PCS versions show that quality of operation of a traditional scheme with a turbine power controller and reactor pressure controller can be significantly improved with the introduction of a high-speed signal of pressure into the reactor controller. The PCS version with the compensation of interrelations between the turbine and reactor controllers constructed according to the same principles as the standard schemes of power units of thermal electric power plant is perspective as well [ru

  5. Which Teaching Strategy Is Better for Enhancing Anti-Phishing Learning Motivation and Achievement? The Concept Maps on Tablet PCs or Worksheets?

    Science.gov (United States)

    Sun, Jerry Chih-Yuan; Lee, Kuan-Hsien

    2016-01-01

    The purpose of this study is to evaluate the feasibility of the integration of concept maps and tablet PCs in anti-phishing education for enhancing students' learning motivation and achievement. The subjects were 155 students from grades 8 and 9. They were divided into an experimental group (77 students) and a control group (78 students). To begin…

  6. Process Information System - Nuclear Power Plant Krsko

    International Nuclear Information System (INIS)

    Mandic, D.; Barbic, B.; Linke, B.; Colak, I.

    1998-01-01

    Original NEK design was using several Process Computer Systems (PCS) for both process control and process supervision. PCS were built by different manufacturers around different hardware and software platforms. Operational experience and new regulatory requirements imposed new technical and functional requirements on the PCS. Requirements such as: - Acquisition of new signals from the technological processes and environment - Implementation of new application programs - Significant improvement of MMI (Man Machine Interface) - Process data transfer to other than Main Control Room (MCR) locations - Process data archiving and capability to retrieve same data for future analysis were impossible to be implemented within old systems. In order to satisfy new requirements, NEK has decided to build new Process Information System (PIS). During the design and construction of the PIS Project Phase I, in addition to the main foreign contractor, there was significant participation of local architect engineering and construction companies. This paper presents experience of NEK and local partners. (author)

  7. Evaluation of the nucledyne passive containment system

    International Nuclear Information System (INIS)

    1981-04-01

    This reports contains: (1) an evaluation by Gilbert/Commonwealth (G/C) of the NucleDyne passive Containment System (PCS) as that conceptual design is applied to a Westinghouse, two loop, Pressurized Water Reactor; (2) an evaluation by Westinghouse of two questions about the impact of the PCS on the Nuclear Steam Supply System (NSSS), which were posed by G/C and best answered by an NSSS vendor; and (3) replies to both the Gilbert/Commonwealth report and the Westinghoue report by NucleDyne Engineering Corporation

  8. Summary of the Control System Cyber-Security (CS)2/HEP Workshop

    CERN Document Server

    Lüders, S

    2007-01-01

    Over the last few years modern accelerator and experiment control systems have increasingly been based on commercial-off-the-shelf products (VME crates, PLCs, SCADA systems, etc.), on Windows or Linux PCs, and on communication infrastructures using Ethernet and TCP/IP. Despite the benefits coming with this (r)evolution, new vulnerabilities are inherited, too: Worms and viruses spread within seconds via the Ethernet cable, and attackers are becoming interested in control systems. Unfortunately, control PCs cannot be patched as fast as office PCs. Even worse, vulnerability scans at CERN using standard IT tools have shown that commercial automation systems lack fundamental security precautions: Some systems crashed during the scan, others could easily be stopped or their process data be altered. The (CS)2/HEP workshop held the weekend before ICALEPCS2007 was intended to present, share, and discuss countermeasures deployed in HEP laboratories in order to secure control systems. This presentation will give a summa...

  9. Summary of The 3rd Control System Cyber-Security (CS)2/HEP Workshop

    CERN Document Server

    Lüders, S

    2011-01-01

    Over the last decade modern accelerator and experiment control systems have increasingly been based on commercial-off-the-shelf products (VME crates, programmable logic controllers (PLCs), supervisory control and data acquisition (SCADA) systems, etc.), on Windows or Linux PCs, and on communication infrastructures using Ethernet and TCP/IP. Despite the benefits coming with this (r)evolution, new vulnerabilities are inherited, too: Worms and viruses spread within seconds via the Ethernet cable, and attackers are becoming interested in control systems. The Stuxnet worm of 2010 against a particular Siemens PLC is a unique example for a sophisticated attack against control systems [1]. Unfortunately, control PCs cannot be patched as fast as office PCs. Even worse, vulnerability scans at CERN using standard IT tools have shown that commercial automation systems lack fundamental security precautions: Some systems crashed during the scan, others could easily be stopped or their process data being ...

  10. Potential Occupant Injury Reduction in Pre-Crash System Equipped Vehicles in the Striking Vehicle of Rear-end Crashes.

    Science.gov (United States)

    Kusano, Kristofer D; Gabler, Hampton C

    2010-01-01

    To mitigate the severity of rear-end and other collisions, Pre-Crash Systems (PCS) are being developed. These active safety systems utilize radar and/or video cameras to determine when a frontal crash, such as a front-to-back rear-end collisions, is imminent and can brake autonomously, even with no driver input. Of these PCS features, the effects of autonomous pre-crash braking are estimated. To estimate the maximum potential for injury reduction due to autonomous pre-crash braking in the striking vehicle of rear-end crashes, a methodology is presented for determining 1) the reduction in vehicle crash change in velocity (ΔV) due to PCS braking and 2) the number of injuries that could be prevented due to the reduction in collision severity. Injury reduction was only performed for belted drivers, as unbelted drivers have an unknown risk of being thrown out of position. The study was based on 1,406 rear-end striking vehicles from NASS / CDS years 1993 to 2008. PCS parameters were selected from realistic values and varied to examine the effect on system performance. PCS braking authority was varied from 0.5 G's to 0.8 G's while time to collision (TTC) was held at 0.45 seconds. TTC was then varied from 0.3 second to 0.6 seconds while braking authority was held constant at 0.6 G's. A constant braking pulse (step function) and ramp-up braking pulse were used. The study found that automated PCS braking could reduce the crash ΔV in rear-end striking vehicles by an average of 12% - 50% and avoid 0% - 14% of collisions, depending on PCS parameters. Autonomous PCS braking could potentially reduce the number of injured drivers who are belted by 19% to 57%.

  11. Status of the new WEST plasma control system

    International Nuclear Information System (INIS)

    Ravene, Nathalie; Nouailletas, Rémy; Signoret, Jacqueline; Guillerminet, Bernard; Treutterrer, Wolfgang; Spring, Anett; Masand, Harish; Dhongde, Jasraj; Bhandarkar, Manisha; Rapson, Chris; Laqua, Heike; Lewerentz, Marc; Moreau, Philippe; Brémond, Sylvain; Allegretti, Ludovic; Raupp, Gerhard; Werner, Andreas; Laurent, François Saint; Nardon, Eric

    2016-01-01

    The WEST (W – for Tungsten – Environment in Steady state Tokamak) project is aiming at minimizing technology and operational risks of a full tungsten actively cooled divertor on ITER. It was started in 2013 and consists in transforming the Tore Supra tokamak into an X point divertor device, while taking advantage of its long discharge capability. To operate the next coming operations of WEST, new controllers are required. These developments are an opportunity to develop a new Plasma Control System (PCS) architecture featuring build-in real time handling of both plasma and plants events, thus addressing key ITER needs. The Tore Supra PCS will be refurbished including a new Pulse Schedule Editor (PSE). The main idea is to use a time segmented approach to describe the pulse schedule with a full integration of event handling both on PCS and PSE. Further to detailed requirement specifications and architecture design, two software tools were selected to define and execute a whole plasma discharge defined as a set of time segments. The PCS real-time framework (RTF) is based on an upgraded version of the AUG framework, called DCS (Discharge Control System). The PSE is the Xedit application used on WEGA and under further development for W7-X facility. This paper reports on the status of the new WEST PCS developments. The on-going developments to adapt DCS to the Tore Supra Control infrastructure networks (new real-time network, chronology system and pulse supervision) will be reported. The required preparations for the use of Xedit will be presented, mainly the appropriate formal description of the WEST control system and the implementation of the mapping between the Xedit experiment configuration and DCS configuration files.

  12. Status of the new WEST plasma control system

    Energy Technology Data Exchange (ETDEWEB)

    Ravene, Nathalie, E-mail: nathalie.ravenel@gmail.com [IRFM, CEA, F-13108 Saint Paul lez Durance (France); Nouailletas, Rémy; Signoret, Jacqueline; Guillerminet, Bernard [IRFM, CEA, F-13108 Saint Paul lez Durance (France); Treutterrer, Wolfgang [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany); Spring, Anett [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Masand, Harish; Dhongde, Jasraj; Bhandarkar, Manisha [Institute for Plasma Research (IPR), Near Indira Bridge, Bhat, Gandhinagar, 382 428 Gujarat (India); Rapson, Chris [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany); Laqua, Heike; Lewerentz, Marc [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Moreau, Philippe; Brémond, Sylvain; Allegretti, Ludovic [IRFM, CEA, F-13108 Saint Paul lez Durance (France); Raupp, Gerhard [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany); Werner, Andreas [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Laurent, François Saint; Nardon, Eric [IRFM, CEA, F-13108 Saint Paul lez Durance (France)

    2016-11-15

    The WEST (W – for Tungsten – Environment in Steady state Tokamak) project is aiming at minimizing technology and operational risks of a full tungsten actively cooled divertor on ITER. It was started in 2013 and consists in transforming the Tore Supra tokamak into an X point divertor device, while taking advantage of its long discharge capability. To operate the next coming operations of WEST, new controllers are required. These developments are an opportunity to develop a new Plasma Control System (PCS) architecture featuring build-in real time handling of both plasma and plants events, thus addressing key ITER needs. The Tore Supra PCS will be refurbished including a new Pulse Schedule Editor (PSE). The main idea is to use a time segmented approach to describe the pulse schedule with a full integration of event handling both on PCS and PSE. Further to detailed requirement specifications and architecture design, two software tools were selected to define and execute a whole plasma discharge defined as a set of time segments. The PCS real-time framework (RTF) is based on an upgraded version of the AUG framework, called DCS (Discharge Control System). The PSE is the Xedit application used on WEGA and under further development for W7-X facility. This paper reports on the status of the new WEST PCS developments. The on-going developments to adapt DCS to the Tore Supra Control infrastructure networks (new real-time network, chronology system and pulse supervision) will be reported. The required preparations for the use of Xedit will be presented, mainly the appropriate formal description of the WEST control system and the implementation of the mapping between the Xedit experiment configuration and DCS configuration files.

  13. Implementing the theories: A fully integrated project control system that's implemented and works

    International Nuclear Information System (INIS)

    Harris, R.E.

    1994-01-01

    Using the theories presented in DOE Orders 4700.1, 1332.1A, and Notice 4700.5 as the basis for system design, the Fernald Environmental Restoration Management Corporation (FERMCO) has developed and implemented a Project Control System (PCS) that complies with requirements and provides DOE and FERMCO management with timely performance measurement information. To this extent, the FERMCO PCS probably is similar to the systems of the majority of the contractors in the DOE complex. In fact. this facet of the FERMCO PCS generally mirrors those used on projects around the world by FERMCO's parent company, Fluor Daniel. Starting with this open-quotes platformclose quotes, the vision and challenge of creating a fully integrated system commenced. An open-architecture systems approach is the factor that most greatly influenced and enabled the successful development and implementation of the Project Control System for the Fernald Environmental Management Project. All aspects of a fully integrated system were considered during the design phase. The architecture of the FERMCO system enables seamless, near real-time, transfer of data both from and to the Project Control System with all other related systems. The primary systems that provide and share data with the Project Control System include those used by the Payroll, Accounting, Procurement, and Human Resources organizations. To enable data linking with these organizations, the resource codes were designed to map many-to-one from their detailed codes to the summarized codes used in the PCS

  14. Summary of State-of-the-Art Power Conversion Systems for Energy Storage Applications

    Energy Technology Data Exchange (ETDEWEB)

    Atcitty, S.; Gray-Fenner, A.; Ranade, S.

    1998-09-01

    The power conversion system (PCS) is a vital part of many energy storage systems. It serves as the interface between the storage device, an energy source, and an AC load. This report summarizes the results of an extensive study of state-of-the-art power conversion systems used for energy storage applications. The purpose of the study was to investigate the potential for cost reduction and performance improvement in these power conversion systems and to provide recommendations for fiture research and development. This report provides an overview of PCS technology, a description of several state-of-the-art power conversion systems and how they are used in specific applications, a summary of four basic configurations for l:he power conversion systems used in energy storage applications, a discussion of PCS costs and potential cost reductions, a summary of the stancku-ds and codes relevant to the technology, and recommendations for future research and development.

  15. FFTF control system experience

    International Nuclear Information System (INIS)

    Warrick, R.P.

    1981-01-01

    The FFTF control systems provide control equipment for safe and efficient operation of the plant. For convenience, these systems will be divided into three parts for discussions: (1) Plant Protection System (PPS); (2) Plant Control System (PCS); and (3) General Observations. Performance of each of these systems is discussed

  16. Extending the capabilities of the DIII-D Plasma Control System for worldwide fusion research collaborations

    International Nuclear Information System (INIS)

    Penaflor, B.G.; Ferron, J.R.; Walker, M.L.; Humphreys, D.A.; Leuer, J.A.; Piglowski, D.A.; Johnson, R.D.; Xiao, B.J.; Hahn, S.H.; Gates, D.A.

    2009-01-01

    This paper will discuss the recent enhancements which have been made to the DIII-D Plasma Control System (PCS) in order to further extend its usefulness as a shared tool for worldwide fusion research. The PCS developed at General Atomics is currently being used in a number of fusion research experiments worldwide, including the DIII-D Tokamak Facility in San Diego, and most recently the KSTAR Tokamak in South Korea. A number of enhancements have been made to support the ongoing needs of the DIII-D Tokamak in addition to meeting the needs of other PCS users worldwide. Details of the present PCS hardware and software architecture along with descriptions of the latest enhancements will be given.

  17. Product Configuration Systems and Consequences for Productivity and Quality

    DEFF Research Database (Denmark)

    Pedersen, Jørgen Lindgaard; Edwards, Kasper

    2004-01-01

    with informations about expected and realised costs and benefits in implemented PCS's we have the following results: the three highest aggregated scoring expected benefits are: 1)improved quality in specifications, 2)lower turnaround time, and 3)using less resources.The results achieved are in accordance......Product Configuration Systems (PCS) are systems to produce quotations to potential buyers of the products an enterprise produces. Typically the products are complex and will first be produced according to specific needs from the customers. From twelve case studies in Danish industry...

  18. Job coding (PCS 2003): feedback from a study conducted in an Occupational Health Service

    Science.gov (United States)

    Henrotin, Jean-Bernard; Vaissière, Monique; Etaix, Maryline; Malard, Stéphane; Dziurla, Mathieu; Lafon, Dominique

    2016-10-19

    Aim: To examine the quality of manual job coding carried out by occupational health teams with access to a software application that provides assistance in job and business sector coding (CAPS). Methods: Data from a study conducted in an Occupational Health Service were used to examine the first-level coding of 1,495 jobs by occupational health teams according to the French job classification entitled “PSC- Professions and socio-professional categories” (INSEE, 2003 version). A second level of coding was also performed by an experienced coder and the first and second level codes were compared. Agreement between the two coding systems was studied using the kappa coefficient (κ) and frequencies were compared by Chi2 tests. Results: Missing data or incorrect codes were observed for 14.5% of social groups (1 digit) and 25.7% of job codes (4 digits). While agreement between the first two levels of PCS 2003 appeared to be satisfactory (κ=0.73 and κ=0.75), imbalances in reassignment flows were effectively noted. The divergent job code rate was 48.2%. Variation in the frequency of socio-occupational variables was as high as 8.6% after correcting for missing data and divergent codes. Conclusions: Compared with other studies, the use of the CAPS tool appeared to provide effective coding assistance. However, our results indicate that job coding based on PSC 2003 should be conducted using ancillary data by personnel trained in the use of this tool.

  19. Cerebellar cortex development in the weaver condition presents regional and age-dependent abnormalities without differences in Purkinje cells neurogenesis.

    Science.gov (United States)

    Martí, Joaquín; Santa-Cruz, María C; Hervás, José P; Bayer, Shirley A; Villegas, Sandra

    2016-01-01

    Ataxias are neurological disorders associated with the degeneration of Purkinje cells (PCs). Homozygous weaver mice (wv/wv) have been proposed as a model for hereditary cerebellar ataxia because they present motor abnormalities and PC loss. To ascertain the physiopathology of the weaver condition, the development of the cerebellar cortex lobes was examined at postnatal day (P): P8, P20 and P90. Three approaches were used: 1) quantitative determination of several cerebellar features; 2) qualitative evaluation of the developmental changes occurring in the cortical lobes; and 3) autoradiographic analyses of PC generation and placement. Our results revealed a reduction in the size of the wv/wv cerebellum as a whole, confirming previous results. However, as distinguished from these reports, we observed that quantified parameters contribute differently to the abnormal growth of the wv/wv cerebellar lobes. Qualitative analysis showed anomalies in wv/wv cerebellar cytoarchitecture, depending on the age and lobe analyzed. Such abnormalities included the presence of the external granular layer after P20 and, at P90, ectopic cells located in the molecular layer following several placement patterns. Finally, we obtained autoradiographic evidence that wild-type and wv/wv PCs presented similar neurogenetic timetables, as reported. However, the innovative character of this current work lies in the fact that the neurogenetic gradients of wv/wv PCs were not modified from P8 to P90. A tendency for the accumulation of late-formed PCs in the anterior and posterior lobes was found, whereas early-generated PCs were concentrated in the central and inferior lobes. These data suggested that wv/wv PCs may migrate properly to their final destinations. The extrapolation of our results to patients affected with cerebellar ataxias suggests that all cerebellar cortex lobes are affected with several age-dependent alterations in cytoarchitectonics. We also propose that PC loss may be regionally

  20. Does pelvicaliceal system anatomy affect success of percutaneous nephrolithotomy?

    Science.gov (United States)

    Binbay, Murat; Akman, Tolga; Ozgor, Faruk; Yazici, Ozgur; Sari, Erhan; Erbin, Akif; Kezer, Cem; Sarilar, Omer; Berberoglu, Yalcın; Muslumanoglu, Ahmet Yaser

    2011-10-01

    To investigate the effect of the pelvicaliceal system (PCS) anatomy on the percutaneous nephrolithotomy (PCNL) success rate. Although the caliceal anatomy is effective for stone clearance after shock wave lithotripsy and retrograde intrarenal lithotripsy, the effect of the caliceal anatomy after PCNL has not been evaluated to date. A total of 498 patients who had undergone PCNL and preoperative intravenous urography were enrolled in our study. Kidney-related anatomic factors, such as the PCS surface area and type, degree of hydronephrosis, infundibulopelvic angle, upper-lower calix angle, infundibular length, and infundibular width were calculated using intravenous urography. The association between the PCNL success rate and kidney-related anatomic factors was retrospectively analyzed using chi-square tests, Fisher's exact test, Mann-Whitney U test, and forward stepwise regression analysis. A success rate of 78.1% was achieved. No difference was seen the success rates among the PCS types. The mean PCS surface area was 20.1 ± 9.7 cm(2) in patients with successful outcomes and 24.5 ± 10.2 cm(2) in patients with remaining stones (P = .001). The mean infundibulopelvic angle, upper-lower calix angle, infundibular length, and infundibular width were similar in both groups. Multivariate binary logistic regression analysis showed that stone configuration and PCS surface area were independent factors affecting the PCNL success rates. The results of our study have shown that the PCS surface area is the only anatomic factor that affects the PCNL success rate and patients with a PCS surface area <20.5 cm(2) have greater PCNL success. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Geographical National Condition and Complex System

    Directory of Open Access Journals (Sweden)

    WANG Jiayao

    2016-01-01

    Full Text Available The significance of studying the complex system of geographical national conditions lies in rationally expressing the complex relationships of the “resources-environment-ecology-economy-society” system. Aiming to the problems faced by the statistical analysis of geographical national conditions, including the disunity of research contents, the inconsistency of range, the uncertainty of goals, etc.the present paper conducted a range of discussions from the perspectives of concept, theory and method, and designed some solutions based on the complex system theory and coordination degree analysis methods.By analyzing the concepts of geographical national conditions, geographical national conditions survey and geographical national conditions statistical analysis, as well as investigating the relationships between theirs, the statistical contents and the analytical range of geographical national conditions are clarified and defined. This investigation also clarifies the goals of the statistical analysis by analyzing the basic characteristics of the geographical national conditions and the complex system, and the consistency between the analysis of the degree of coordination and statistical analyses. It outlines their goals, proposes a concept for the complex system of geographical national conditions, and it describes the concept. The complex system theory provides new theoretical guidance for the statistical analysis of geographical national conditions. The degree of coordination offers new approaches on how to undertake the analysis based on the measurement method and decision-making analysis scheme upon which the complex system of geographical national conditions is based. It analyzes the overall trend via the degree of coordination of the complex system on a macro level, and it determines the direction of remediation on a micro level based on the degree of coordination among various subsystems and of single systems. These results establish

  2. Plant inspection tours with mobile data logging system

    International Nuclear Information System (INIS)

    Roesser, U.

    2006-01-01

    The MDE Mobile Data Logging System has been introduced in a number of German power plants for efficient logging, evaluation, and quality-assured documentation of data recorded on plant inspection tours by means of pocket PCs instead of slips of paper. It will be installed in other nuclear power plants in the near future. The MDE system is composed of the pocket PCs for logging data during plant inspection tours, the associated docking stations installed in the respective areas of application, one PC or, if necessary, several PCs with the appropriate user software, and the associated network links. To install the software in the power plant, lists of rooms and measurement stations as well as other positions on an inspection course are transmitted to the MDE system. When the system has been commissioned, inspection tours are planned in accordance with past experience and optimized in the computer. User experience is taken into account in program updates. New functions improve user comfort and ease of evaluation. Additions to the MDE software, and applications in other areas, are tentatively planned and will be implemented as the need arises. (orig.)

  3. Identification and Optimal Growth Conditions of Actinomycetes Isolated From Mangrove Environment

    International Nuclear Information System (INIS)

    Ameerah Abdul Hamid; Suhaidi Ariffin; Sharifah Aminah Syed Mohamad

    2015-01-01

    Actinomycetes are classified as saprophytes that play a significant role in the breakdown of organic matters into more readily assimilable nutrients. They are also known to produce a variety of secondary metabolites, which are useful for human, veterinary medicine and agriculture applications. The optimum growth conditions of actinomycetes isolated from mangrove environment at different temperature, pH and sodium chloride (NaCl) concentration were studied. The identification of the isolates by both biochemical test and 16S rRNA analysis was also done. All isolates were grown in ISP1 medium at different temperature (25, 30, 37 and 40 degree Celsius); pH (3.5, 5, 7 and 9); and salt concentration (0, 3, 5 and 7 % w/v). The optimum temperature for KMS1 and KMH2 isolates was at 25 degree Celsius. However, the optimum temperature for PCS1 and PMH1A was at 30 and 37 degree Celsius respectively. The optimum pH was pH 7 and the most preferred NaCl concentration of all isolates was at 3 % (w/v). All isolates showed negative result for carbohydrate fermentation except for KMS1 which showed utilisation of D-Fructose sugar with acid production. Only KMS1 and PCS1 exhibited amylolytic and proteolytic activity. The isolates were successfully identified as Streptomyces variables (KMS1), Streptomyces rubrolavendulae (KMH2), Streptomyces spp. CPE333 (PCS1) and Actinomycetales bacterium (PMH1A). (author)

  4. Progress in Development of the ITER Plasma Control System Simulation Platform

    Science.gov (United States)

    Walker, Michael; Humphreys, David; Sammuli, Brian; Ambrosino, Giuseppe; de Tommasi, Gianmaria; Mattei, Massimiliano; Raupp, Gerhard; Treutterer, Wolfgang; Winter, Axel

    2017-10-01

    We report on progress made and expected uses of the Plasma Control System Simulation Platform (PCSSP), the primary test environment for development of the ITER Plasma Control System (PCS). PCSSP will be used for verification and validation of the ITER PCS Final Design for First Plasma, to be completed in 2020. We discuss the objectives of PCSSP, its overall structure, selected features, application to existing devices, and expected evolution over the lifetime of the ITER PCS. We describe an archiving solution for simulation results, methods for incorporating physics models of the plasma and physical plant (tokamak, actuator, and diagnostic systems) into PCSSP, and defining characteristics of models suitable for a plasma control development environment such as PCSSP. Applications of PCSSP simulation models including resistive plasma equilibrium evolution are demonstrated. PCSSP development supported by ITER Organization under ITER/CTS/6000000037. Resistive evolution code developed under General Atomics' Internal funding. The views and opinions expressed herein do not necessarily reflect those of the ITER Organization.

  5. Economic analysis of coal-based polygeneration system for methanol and power production

    International Nuclear Information System (INIS)

    Lin, Hu; Jin, Hongguang; Gao, Lin; Han, Wei

    Polygeneration system for chemical and power co-production has been regarded as one of promising technologies to use fossil fuel more efficiently and cleanly. In this paper the thermodynamic and economic performances of three types of coal-based polygeneration system were investigated and the influence of energy saving of oxygenation systems on system economic performance was revealed. The primary cost saving ratio (PCS) is presented as a criterion, which represents the cost saving of polygeneration system compared with the single-product systems with the same products outputs, to evaluate economic advantages of polygeneration system. As a result, the system, adopting un-reacted syngas partly recycled to the methanol synthesis reactor and without the shift process, can get the optimal PCS of 11.8%, which results from the trade-off between the installed capital cost saving and the energy saving effects on the cost saving, and represents the optimal coupling relationship among chemical conversion, energy utilization and economic performance. And both of fuel price and the level of equipment capital cost affect on PCS faintly. This paper provides an evaluation method for polygeneration systems based on both technical and economic viewpoints. (author)

  6. The Personal Hearing System—A Software Hearing Aid for a Personal Communication System

    Directory of Open Access Journals (Sweden)

    Giso Grimm

    2009-01-01

    Full Text Available A concept and architecture of a personal communication system (PCS is introduced that integrates audio communication and hearing support for the elderly and hearing-impaired through a personal hearing system (PHS. The concept envisions a central processor connected to audio headsets via a wireless body area network (WBAN. To demonstrate the concept, a prototype PCS is presented that is implemented on a netbook computer with a dedicated audio interface in combination with a mobile phone. The prototype can be used for field-testing possible applications and to reveal possibilities and limitations of the concept of integrating hearing support in consumer audio communication devices. It is shown that the prototype PCS can integrate hearing aid functionality, telephony, public announcement systems, and home entertainment. An exemplary binaural speech enhancement scheme that represents a large class of possible PHS processing schemes is shown to be compatible with the general concept. However, an analysis of hardware and software architectures shows that the implementation of a PCS on future advanced cell phone-like devices is challenging. Because of limitations in processing power, recoding of prototype implementations into fixed point arithmetic will be required and WBAN performance is still a limiting factor in terms of data rate and delay.

  7. The Personal Hearing System—A Software Hearing Aid for a Personal Communication System

    Science.gov (United States)

    Grimm, Giso; Guilmin, Gwénaël; Poppen, Frank; Vlaming, Marcel S. M. G.; Hohmann, Volker

    2009-12-01

    A concept and architecture of a personal communication system (PCS) is introduced that integrates audio communication and hearing support for the elderly and hearing-impaired through a personal hearing system (PHS). The concept envisions a central processor connected to audio headsets via a wireless body area network (WBAN). To demonstrate the concept, a prototype PCS is presented that is implemented on a netbook computer with a dedicated audio interface in combination with a mobile phone. The prototype can be used for field-testing possible applications and to reveal possibilities and limitations of the concept of integrating hearing support in consumer audio communication devices. It is shown that the prototype PCS can integrate hearing aid functionality, telephony, public announcement systems, and home entertainment. An exemplary binaural speech enhancement scheme that represents a large class of possible PHS processing schemes is shown to be compatible with the general concept. However, an analysis of hardware and software architectures shows that the implementation of a PCS on future advanced cell phone-like devices is challenging. Because of limitations in processing power, recoding of prototype implementations into fixed point arithmetic will be required and WBAN performance is still a limiting factor in terms of data rate and delay.

  8. A Retrospective 2D Morphometric Analysis of Adult Female Chiari Type I Patients with Commonly Reported and Related Conditions

    Directory of Open Access Journals (Sweden)

    Maggie S. Eppelheimer

    2018-01-01

    Full Text Available Purpose: Researchers have sought to better understand Chiari type I malformation (CMI through morphometric measurements beyond tonsillar position (TP. Soft tissue and bone structures within the brain and craniocervical junction have been shown to be different for CMI patients compared to healthy controls. Yet, several morphological characteristics have not been consistently associated with CMI. CMI is also associated with different prevalent conditions (PCs such as syringomyelia, pseudotumor, Ehlers-Danlos syndrome (EDS, scoliosis, and craniocervical instability. The goal of this study was two-fold: (1 to identify unique morphological characteristics of PCs, and (2 to better explain inconsistent results from case-control comparisons of CMI.Methods: Image, demographic, and PC information was obtained through the Chiari1000, a self-report web-accessed database. Twenty-eight morphometric measurements (MMs were performed on the cranial MR images of 236 pre-surgery adult female CMI participants and 140 female healthy control participants. Custom software was used to measure 28 structures within the posterior cranial fossa (PCF compartment, craniocervical junction, oral cavity, and intracranial area on midsagittal MR images for each participant.Results: Morphometric analysis of adult females indicated a smaller McRae line length in CMI participants with syringomyelia compared to those without syringomyelia. TP was reduced in CMI participants with EDS than those without EDS. Basion to posterior axial line was significantly longer in CMI participants with scoliosis compared to those without scoliosis. No additional MMs were found to differ between CMI participants with and without a specific PC. Four morphometric differences were found to be consistently different between CMI participants and healthy controls regardless of PC: larger TP and a smaller clivus length, fastigium, and corpus callosum height in CMI participants.Conclusion: Syringomyelia, EDS

  9. Experiment data report for Loft anticipated transient experiments 16-1, 16-2, and 16-3

    International Nuclear Information System (INIS)

    Batt, D.L.; Carpenter, J.M.

    1980-12-01

    This report presents uninterpreted experimental data from the second, third, and fourth anticipated transient experiments (Experiments L6-2, L6-1, and L6-3), conducted in the Loss-of-Fluid Test (LOFT) facility. Experiment L6-2 simulated a loss of forced primary coolant flow in a large PWR by tripping power to primary coolant pump motor generator sets, allowing the pumps to coast down under the influence of the flywheel system. Reactor scram initiated on indication of low flow in the primary coolant system (PCS). Experiment L6-1 simulated a loss of steam load in a large PWR by closing the steam flow control valve which reduced heat removal from the secondary coolant system and caused the PCS temperature and pressure to increase until reactor scram initiated on indication on high PCS pressure. Experiment L6-3 simulated an excessive load increase in a large PWR by opening the steam flow control valve at its maximum rate. PCS temperature and pressure decreased, causing the reactor to scram on indication of low PCS pressure. All experiments were complete when the plant was returned to a hot-standby condition

  10. Feedback control systems for non-linear simulation of operational transients in LMFBRs

    International Nuclear Information System (INIS)

    Khatib-Rahbar, M.; Agrawal, A.K.; Srinivasan, E.S.

    Adequate modeling of Plant Control Systems (PCS) for the study of Anticipated Transients Without Scram (ATWS) is of considerable significance in the design, operation and safety evaluation of Liquid-Metal-Cooled Fast Breeder Reactor (LMFBR) systems. To assess the system response to high frequency, low consequence events, the plant needs to be dynamically simulated. The description of analytical and numerical models for PCS that have been developed and incorporated into the loop version of the Super System Code (SSC-L) are described. The importance of detailed modeling of control systems is discussed. Sample transient results obtained for a 10% ramp change of load in 40 s in the Clinch River Breeder Reactor Plant (CRBRP) are also shown

  11. Synaptic responses evoked by tactile stimuli in Purkinje cells in mouse cerebellar cortex Crus II in vivo.

    Directory of Open Access Journals (Sweden)

    Chun-Ping Chu

    Full Text Available Sensory stimuli evoke responses in cerebellar Purkinje cells (PCs via the mossy fiber-granule cell pathway. However, the properties of synaptic responses evoked by tactile stimulation in cerebellar PCs are unknown. The present study investigated the synaptic responses of PCs in response to an air-puff stimulation on the ipsilateral whisker pad in urethane-anesthetized mice.Thirty-three PCs were recorded from 48 urethane-anesthetized adult (6-8-week-old HA/ICR mice by somatic or dendritic patch-clamp recording and pharmacological methods. Tactile stimulation to the ipsilateral whisker pad was delivered by an air-puff through a 12-gauge stainless steel tube connected with a pressurized injection system. Under current-clamp conditions (I = 0, the air-puff stimulation evoked strong inhibitory postsynaptic potentials (IPSPs in the somata of PCs. Application of SR95531, a specific GABA(A receptor antagonist, blocked IPSPs and revealed stimulation-evoked simple spike firing. Under voltage-clamp conditions, tactile stimulation evoked a sequence of transient inward currents followed by strong outward currents in the somata and dendrites in PCs. Application of SR95531 blocked outward currents and revealed excitatory postsynaptic currents (EPSCs in somata and a temporal summation of parallel fiber EPSCs in PC dendrites. We also demonstrated that PCs respond to both the onset and offset of the air-puff stimulation.These findings indicated that tactile stimulation induced asynchronous parallel fiber excitatory inputs onto the dendrites of PCs, and failed to evoke strong EPSCs and spike firing in PCs, but induced the rapid activation of strong GABA(A receptor-mediated inhibitory postsynaptic currents in the somata and dendrites of PCs in the cerebellar cortex Crus II in urethane-anesthetized mice.

  12. Operational experience with the Sizewell B integrated plant computer system

    International Nuclear Information System (INIS)

    Ladner, J.E.J.; Alexander, N.C.; Fitzpatrick, J.A.

    1997-01-01

    The Westinghouse Integrated System for Centralised Operation (WISCO) is the primary plant control system at the Sizewell B Power Station. It comprises three subsystems; the High Integrity Control System (HICS), the Process Control System (PCS) and the Distributed Computer system (DCS). The HICS performs the control and data acquisition of nuclear safety significant plant systems. The PCS uses redundant data processing unit pairs. The workstations and servers of the DCS communicate with each other over a standard ethernet. The maintenance requirements for every plant system are covered by a Maintenance Strategy Report. The breakdown of these reports is listed. The WISCO system has performed exceptionally well. Due to the diagnostic information presented by the HICS, problems could normally be resolved within 24 hours. There have been some 200 outstanding modifications to the system. The procedure of modification is briefly described. (A.K.)

  13. Overview of the preliminary design of the ITER plasma control system

    Science.gov (United States)

    Snipes, J. A.; Albanese, R.; Ambrosino, G.; Ambrosino, R.; Amoskov, V.; Blanken, T. C.; Bremond, S.; Cinque, M.; de Tommasi, G.; de Vries, P. C.; Eidietis, N.; Felici, F.; Felton, R.; Ferron, J.; Formisano, A.; Gribov, Y.; Hosokawa, M.; Hyatt, A.; Humphreys, D.; Jackson, G.; Kavin, A.; Khayrutdinov, R.; Kim, D.; Kim, S. H.; Konovalov, S.; Lamzin, E.; Lehnen, M.; Lukash, V.; Lomas, P.; Mattei, M.; Mineev, A.; Moreau, P.; Neu, G.; Nouailletas, R.; Pautasso, G.; Pironti, A.; Rapson, C.; Raupp, G.; Ravensbergen, T.; Rimini, F.; Schneider, M.; Travere, J.-M.; Treutterer, W.; Villone, F.; Walker, M.; Welander, A.; Winter, A.; Zabeo, L.

    2017-12-01

    An overview of the preliminary design of the ITER plasma control system (PCS) is described here, which focusses on the needs for 1st plasma and early plasma operation in hydrogen/helium (H/He) up to a plasma current of 15 MA with moderate auxiliary heating power in low confinement mode (L-mode). Candidate control schemes for basic magnetic control, including divertor operation and kinetic control of the electron density with gas puffing and pellet injection, were developed. Commissioning of the auxiliary heating systems is included as well as support functions for stray field topology and real-time plasma boundary reconstruction. Initial exception handling schemes for faults of essential plant systems and for disruption protection were developed. The PCS architecture was also developed to be capable of handling basic control for early commissioning and the advanced control functions that will be needed for future high performance operation. A plasma control simulator is also being developed to test and validate control schemes. To handle the complexity of the ITER PCS, a systems engineering approach has been adopted with the development of a plasma control database to keep track of all control requirements.

  14. Progress and plan of KSTAR plasma control system upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Sang-hee, E-mail: hahn76@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Kim, Y.J. [National Fusion Research Institute, Daejeon (Korea, Republic of); Penaflor, B.G. [General Atomics, San Diego, CA (United States); Bak, J.G.; Han, H.; Hong, J.S.; Jeon, Y.M.; Jeong, J.H.; Joung, M.; Juhn, J.W.; Kim, J.S.; Kim, H.S.; Lee, W.R.; Woo, M.H. [National Fusion Research Institute, Daejeon (Korea, Republic of); Eidietis, N.W.; Ferron, J.R.; Humphreys, D.A.; Hyatt, A.; Johnson, R.D.; Piglowski, D.A. [General Atomics, San Diego, CA (United States); and others

    2016-11-15

    Highlights: • Recent achievements of the KSTAR plasma control system are described. • Requirements and results of the testbed system for the future upgrade of the KSTAR plasma control system are presented. • An overview of the upgrade layout based is given. - Abstract: The plasma control system (PCS) has been one of essential systems in annual KSTAR plasma campaigns: starting from a single-process version in 2008, extensive upgrades are done through the previous 7 years in order to achieve major goals of KSTAR performance enhancement. Major implementations are explained in this paper. In consequences of successive upgrades, the present KSTAR PCS is able to achieve ∼48 s of 500 kA plasma pulses with full real-time shaping controls and real-time NB power controls. It has become a huge system capable of dealing with 8 separate categories of algorithms, 26 actuators directly controllable during the shot, and real-time data communication units consisting of +180 analog channels and +600 digital input/outputs through the reflective memory (RFM) network. The next upgrade of the KSTAR PCS is planned in 2015 before the campaign. An overview of the upgrade layout will be given for this paper. The real-time system box is planned to use the CERN MRG-Realtime OS, an ITER-compatible standard operating system. New hardware is developed for faster real-time streaming system for future installations of actuators/diagnostics.

  15. The ISOLDE control system

    International Nuclear Information System (INIS)

    Deloose, I.; Pace, A.

    1994-01-01

    The two CERN isotope separators named ISOLDE have been running on the new Personal Computer (PC) based control system since April 1992. The new architecture that makes heavy use of the commercial software and hardware of the PC market has been implemented on the 1700 geographically distributed control channels of the two separators and their experimental area. Eleven MSDOS Intel-based PCs with approximately 80 acquisition and control boards are used to access the equipment and are controlled from three PCs running Microsoft Windows used as consoles through a Novell Local Area Network. This paper describes the interesting solutions found and discusses the reduced programming workload and costs that have been obtained. ((orig.))

  16. The ISOLDE control system

    Science.gov (United States)

    Deloose, I.; Pace, A.

    1994-12-01

    The two CERN isotope separators named ISOLDE have been running on the new Personal Computer (PC) based control system since April 1992. The new architecture that makes heavy use of the commercial software and hardware of the PC market has been implemented on the 1700 geographically distributed control channels of the two separators and their experimental area. Eleven MSDOS Intel-based PCs with approximately 80 acquisition and control boards are used to access the equipment and are controlled from three PCs running Microsoft Windows used as consoles through a Novell Local Area Network. This paper describes the interesting solutions found and discusses the reduced programming workload and costs that have been obtained.

  17. Comparative performance of precommercial cellulases hydrolyzing pretreated corn stover

    Science.gov (United States)

    2011-01-01

    Background Cellulases and related hydrolytic enzymes represent a key cost factor for biochemical conversion of cellulosic biomass feedstocks to sugars for biofuels and chemicals production. The US Department of Energy (DOE) is cost sharing projects to decrease the cost of enzymes for biomass saccharification. The performance of benchmark cellulase preparations produced by Danisco, DSM, Novozymes and Verenium to convert pretreated corn stover (PCS) cellulose to glucose was evaluated under common experimental conditions and is reported here in a non-attributed manner. Results Two hydrolysis modes were examined, enzymatic hydrolysis (EH) of PCS whole slurry or washed PCS solids at pH 5 and 50°C, and simultaneous saccharification and fermentation (SSF) of washed PCS solids at pH 5 and 38°C. Enzymes were dosed on a total protein mass basis, with protein quantified using both the bicinchoninic acid (BCA) assay and the Bradford assay. Substantial differences were observed in absolute cellulose to glucose conversion performance levels under the conditions tested. Higher cellulose conversion yields were obtained using washed solids compared to whole slurry, and estimated enzyme protein dosages required to achieve a particular cellulose conversion to glucose yield were extremely dependent on the protein assay used. All four enzyme systems achieved glucose yields of 90% of theoretical or higher in SSF mode. Glucose yields were reduced in EH mode, with all enzymes achieving glucose yields of at least 85% of theoretical on washed PCS solids and 75% in PCS whole slurry. One of the enzyme systems ('enzyme B') exhibited the best overall performance. However in attaining high conversion yields at lower total enzyme protein loadings, the relative and rank ordered performance of the enzyme systems varied significantly depending upon which hydrolysis mode and protein assay were used as the basis for comparison. Conclusions This study provides extensive information about the

  18. Comparative performance of precommercial cellulases hydrolyzing pretreated corn stover

    Directory of Open Access Journals (Sweden)

    Mohagheghi Ali

    2011-09-01

    Full Text Available Abstract Background Cellulases and related hydrolytic enzymes represent a key cost factor for biochemical conversion of cellulosic biomass feedstocks to sugars for biofuels and chemicals production. The US Department of Energy (DOE is cost sharing projects to decrease the cost of enzymes for biomass saccharification. The performance of benchmark cellulase preparations produced by Danisco, DSM, Novozymes and Verenium to convert pretreated corn stover (PCS cellulose to glucose was evaluated under common experimental conditions and is reported here in a non-attributed manner. Results Two hydrolysis modes were examined, enzymatic hydrolysis (EH of PCS whole slurry or washed PCS solids at pH 5 and 50°C, and simultaneous saccharification and fermentation (SSF of washed PCS solids at pH 5 and 38°C. Enzymes were dosed on a total protein mass basis, with protein quantified using both the bicinchoninic acid (BCA assay and the Bradford assay. Substantial differences were observed in absolute cellulose to glucose conversion performance levels under the conditions tested. Higher cellulose conversion yields were obtained using washed solids compared to whole slurry, and estimated enzyme protein dosages required to achieve a particular cellulose conversion to glucose yield were extremely dependent on the protein assay used. All four enzyme systems achieved glucose yields of 90% of theoretical or higher in SSF mode. Glucose yields were reduced in EH mode, with all enzymes achieving glucose yields of at least 85% of theoretical on washed PCS solids and 75% in PCS whole slurry. One of the enzyme systems ('enzyme B' exhibited the best overall performance. However in attaining high conversion yields at lower total enzyme protein loadings, the relative and rank ordered performance of the enzyme systems varied significantly depending upon which hydrolysis mode and protein assay were used as the basis for comparison. Conclusions This study provides extensive

  19. Study of CD69 antigen expression and integrity of leukocyte cellular membrane in stored platelet concentrates following irradiation and treatment with Mirasol® PRT System.

    Science.gov (United States)

    Lachert, Elżbieta; Woźniak, Jolanta; Antoniewicz-Papis, Jolanta; Krzywdzińska, Agnieszka; Kubis, Jolanta; Mikołowska, Agata; Letowska, Magdalena

    2017-01-01

    Leukocytes in transfused blood components, particularly residual lymphocytes, have been shown to contribute to the occurrence of various adverse reactions. One of the most severe is transfusionassociated graft versus host disease (TA-GvHD) following transfusion of blood components contaminated with immunocompetent T lymphocytes. Irradiation is a routine method for protection against TA-GvHD. According to the literature, some pathogen reduction methods have also been proven effective for the inactivation of T lymphocytes, and so they may be considered as an alternative to irradiation. Comparison of CD69 antigen expression and the integrity of the leukocyte cellular membrane in stored platelet concentrates (PCs) following irradiation with the Gammacell 3000 Elan (Nordion Inc., Ottawa, Canada) and treatment with the Mirasol® Pathogen Reduction Technology (PRT) System (Terumo BCT, Lakewood, USA). The study included seven experiments. For each experiment we used 3 PCs, for Mirasol® PRT System treatment (M), for Gammacell 3000 Elan irradiation (R), and for the control (C). 7-amino-actinomycin D (7-AAD, Becton Dickinson, Franklin Lakes, USA) permeability was used to determine lymphocyte viability while CD69 antigen expression was the marker of lymphocyte activation. Analyses of 7-AAD and CD69 antigen expression were performed in a FACS Canto I flow cytometer (Becton Dickinson, USA). During 6 storage days, viable lymphocyte count decreased to 28% (p = 0.001) in the Mirasol® PRT System treated PCs and to 65% (p = 0.004) in the irradiated PCs. A statistically significant increase in CD69 expression in the irradiated PCs was observed; 1.3-fold on day 3 and 1.5-fold on day 6. In the Mirasol ® PRT System treated PCs, no statistically significant increase was observed. The in vitro results suggest that the Mirasol® PRT System is as effective as irradiation due to donor leukocyte inactivation capacity.

  20. Systemic conditions affecting the breast

    International Nuclear Information System (INIS)

    Abbitt, P.L.; DeParedes, E.S.

    1987-01-01

    While the mammogram is most often used in the evaluation of diseases specific to the breast, manifestations of systemic conditions may also be recognized. Congenital systemic conditions such as neurofibromatosis and ectodermal dysplasia have graphic mammographic findings. The effects of diet, hormonal, and medication therapy can also have a dramatic impact on the appearance of the mammogram, as can common clinical states such as congestive heart failure or renal failure. Metastases to the breast from extramammary primaries may be seen mammographically as discrete masses, as causing diffusely increased density of the breast or as abnormal axillary adenopathy. The authors review a variety of conditions and their mammographic appearance

  1. On conditional residual lifetime and conditional inactivity time of k-out-of-n systems

    International Nuclear Information System (INIS)

    Tavangar, Mahdi; Bairamov, Ismihan

    2015-01-01

    In designing structures of technical systems, the reliability engineers often deal with the reliability analysis of coherent systems. Coherent system has monotone structure function and all components of the system are relevant. This paper considers some particular models of coherent systems having identical components with independent lifetimes. The main purpose of the paper is to study conditional residual lifetime of coherent system, given that at a fixed time certain number of components have failed but still there are some functioning components. Different aging and stochastic properties of variables connected with the conditional residual lifetimes of the coherent systems are obtained. An expression for the parent distribution in terms of conditional mean residual lifetime is provided. The similar result is obtained for the conditional mean inactivity time of the failed components of coherent system. The conditional mean inactivity time of failed components presents an interest in many engineering applications where the reliability of system structure is important for designing and constructing of systems. Some illustrative examples with given particular distributions are also presented. - Highlights: • Comparisons of conditional residual lifetime of k-out-of-n systems are derived. • The behavior of the coherent system is explored for IHR distributions. • The parent distribution is expressed in terms of conditional MRL and MIT. • Some illustrative examples are given to clarify the results of the paper.

  2. Performance of desiccant air conditioning system with geothermal energy under different climatic conditions

    International Nuclear Information System (INIS)

    El-Agouz, S.A.; Kabeel, A.E.

    2014-01-01

    Highlights: • The performance of the hybrid air conditioning system is studied. • The influence of important operating parameters are estimated. • The ventilation, makeup and mix cycles are investigated at different climate. • The highest COP of the hybrid air conditioning system is 1.03. • The hybrid system provides a human thermal comfort at different climates. - Abstract: Energy saving still and continue a major seek in our life, due to the continuous increase in energy consumptions. So, a desiccant air conditioning system with geothermal energy is conducted in the current study. The thermal analysis of air conditioning system with its different components desiccant wheel, solar collector, heat exchanger, ground heat exchanger and water spray evaporative cooler is presented. Three different air conditioning cycles are simulated in the current study for different zones like: hot-dry zone, warm-dry zone, hot-humid zone and the warm-humid zone. The results show that the desiccant air conditioning system successfully provides a better thermal comfort condition in different climates. This hybrid system significantly decreases the supplied air temperature from 12.7 to 21.7 °C at different climate zones. When ω in , air and T Reg increasing, COP decreases and the ventilation cycle provides the better COP. The highest COP value of the desiccant air conditioning system is about 1.03 while the lowest value is about 0.15. The SHR of makeup cycle is higher than that ventilation cycle at warm and hot-humid zone and vice versa at warm and hot-dry zone. The highest SHR value of the desiccant air conditioning system is about 0.99 while the lowest value is about 0.2. The T sup,air , ω sup,air , COP and SHR isolines may easily be used for pre-evaluating of various cooling cycles in different climates. The hybrid system provides a human thermal comfort at different climates

  3. Controls in new construction reactors-factory testing of the non-safety portion of the Lungmen nuclear power plant distributed control system

    International Nuclear Information System (INIS)

    Wu, Y. S.; Dick, J. W.; Tetirick, C. W.

    2006-01-01

    /O database is installed on the DCIS and is physically addressed correctly. Test process is injecting a signal at each DCIS hard I/O terminal boundary and verifying correct receipt on the DCIS. b) DCIS Network Stress Test - Confirms system viability under extreme high load conditions beyond the plant could ever experience. Load conditions include alarm showers on the DCIS system to emulate plant upsets. c) System Hardware Configuration Test - These are typical checks of the DCIS system hardware including fault reporting, redundancy, and normal computer functions. d) Performance Test - Test confirms high level hardware and system capability attributes such as control system time response, 'cold start' reboots, and processor loading e) Electromagnetic compatibility tests - To verify the electromagnetic viability of the system and individual components 2. Implementation of Plant Systems and Systems Integration a) MPL Logic Tests -To confirm control functions implemented to system logic performs as expected, and that parameters are passed correctly between system control schemes. b) Data Link (Gateway) Tests- To verify third party interfaces to the DCIS. c) Plant Computer System (PCS) Logic Tests- Tests to verify that higher-level PCS logic is correctly implemented, performs as expected, and parameters are passed correctly between PCS sub-systems and MPL systems. Included the PCS sub-systems, Safety Parameter Display System, Historian, Alarms, Maintenance monitoring etc. 3. Unique Third Party Interfacing and Integration into the DCIS The set of controls for Automatic Power Regulation, Feedwater, and Recirculation Flow are specific in that these systems are implemented on third party Triple Modular Redundant (TMR) hardware, which was connected to the DCIS and are tested via full simulation. The TMR system is supplied by GE Control Solutions on the Mark Vie platform. (authors)

  4. Controls in new construction reactors-factory testing of the non-safety portion of the Lungmen nuclear power plant distributed control system

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Y. S. [Taiwan Power Company, 242, Roosevelt Road, Sec. 3, Taipei 100, Taiwan (China); Dick, J. W. [Invensys System Inc., 33 Commercial St., Foxboro, MA 02035 (United States); Tetirick, C. W. [GE Energy, 1989 Little Orchard Street, San Jose, CA 95125-1030 (United States)

    2006-07-01

    I/O database is installed on the DCIS and is physically addressed correctly. Test process is injecting a signal at each DCIS hard I/O terminal boundary and verifying correct receipt on the DCIS. b) DCIS Network Stress Test - Confirms system viability under extreme high load conditions beyond the plant could ever experience. Load conditions include alarm showers on the DCIS system to emulate plant upsets. c) System Hardware Configuration Test - These are typical checks of the DCIS system hardware including fault reporting, redundancy, and normal computer functions. d) Performance Test - Test confirms high level hardware and system capability attributes such as control system time response, 'cold start' reboots, and processor loading e) Electromagnetic compatibility tests - To verify the electromagnetic viability of the system and individual components 2. Implementation of Plant Systems and Systems Integration a) MPL Logic Tests -To confirm control functions implemented to system logic performs as expected, and that parameters are passed correctly between system control schemes. b) Data Link (Gateway) Tests- To verify third party interfaces to the DCIS. c) Plant Computer System (PCS) Logic Tests- Tests to verify that higher-level PCS logic is correctly implemented, performs as expected, and parameters are passed correctly between PCS sub-systems and MPL systems. Included the PCS sub-systems, Safety Parameter Display System, Historian, Alarms, Maintenance monitoring etc. 3. Unique Third Party Interfacing and Integration into the DCIS The set of controls for Automatic Power Regulation, Feedwater, and Recirculation Flow are specific in that these systems are implemented on third party Triple Modular Redundant (TMR) hardware, which was connected to the DCIS and are tested via full simulation. The TMR system is supplied by GE Control Solutions on the Mark Vie platform. (authors)

  5. Impact of product configuration systems on product profitability and costing accuracy

    DEFF Research Database (Denmark)

    Myrodia, Anna; Kristjansdottir, Katrin; Hvam, Lars

    2017-01-01

    in control of their product assortment, making the right decisions in the sales phase and increasing sales of optimal products. These benefits should have an impact on the company's ability to make more accurate cost estimations in the sales phase, which can positively affect the products’ profitability......This article aims at analyzing the impact of implementing a product configuration system (PCS) on the increased accuracy of the cost calculations and the increased profitability of the products. Companies that have implemented PCSs have achieved substantial benefits in terms of being more...... and after a PCS was implemented. The comparison in the case study revealed that increased accuracy of the cost calculations in the sales phase and consequently increased profitability can be achieved by implementing a PCS....

  6. Occupational dose for the water cooling system of the SEAFP project

    International Nuclear Information System (INIS)

    Sandri, S.; Di Pace, L.

    1996-01-01

    The Occupational Radiation Exposure (ORE) for the water primary cooling system (PCS) of the SEAFP was assessed taking into account the first wall/blanket section only. All the potential radiological sources were considered and the analysis was restricted to the most important source at the PCS, the activated corrosion products (ACP). The relevant dose rate was evaluated using the computer code MCNP. Comparison of the results with the respective values measured at the fission PWR plants made it possible to transfer the parameters relevant to the working activities to the SEAFP PCS. Maintenance and inspection were found to be the only working tasks applicable to the SEAFP circuit and the worker access was considered to be allowed 24 h after the plant shut down only. 12 refs., 11 tabs

  7. ASTRID power conversion system: Assessment on steam and gas options

    International Nuclear Information System (INIS)

    Laffont, Guy; Cachon, Lionel; Jourdain, Vincent; Fauque, Jean Marie

    2013-01-01

    Conclusion: ◆ Two power conversion systems have been investigated for the ASTRID prototype. ◆ Steam PCS: • Most mature system based on a well-developed turbomachinery technology. • High plant efficiency. • Studies on steam generators designs and leak detection systems in progress with the aim of reducing the risk of large SWRs and of limiting its consequences. • Design and licensing safety assessment of a SFR must deal with the Sodium Water Air reaction (SWAR). ◆ Gas PCS: • Strong advantage as it inherently eliminates the SWR and SWAR risks. • Very innovative option: major breakthroughs but feasibility and viability not yet demonstrated. • Remaining technological challenges but no showstopper indentified. • General architecture: investigations in progress to improve performances, operability and maintainability

  8. Product Configuration Systems and Productivity

    DEFF Research Database (Denmark)

    Pedersen, Jørgen Lindgaard; Edwards, Kasper

    2004-01-01

    Twelve companies have been interviewed with the purpose to get information about technical, economic and organisational matters in respect of Product Configuration Systems (PCS).Combinations of qualitative interviews and quantitative scoring have been used in ranking expected and realized results...

  9. A Modular Integrated RFID System for Inventory Control Applications

    Directory of Open Access Journals (Sweden)

    Ross Bunker

    2017-01-01

    Full Text Available Recent advances in single-board computer technology have allowed for lightweight, power-efficient devices, such as the Raspberry Pi, to take the place of desktop PCs in certain applications. This has the potential to disrupt the way many current systems are structured, particularly for inventory management and control applications. In this paper, we explore the design and topology of a modular Radio frequency identification (RFID system for inventory management comprised of self-contained, autonomous scanning, and stationary control PCs in a handheld/portable configuration. While similar solutions for such a system may exist on the commercial market, this proposed development provides a template for an open source flexible, low-cost solution that can be easily expanded to meet the needs of businesses with large and small inventories.

  10. Importance Of Penetration Testing For Legacy Operating System

    Directory of Open Access Journals (Sweden)

    Poorvi Bhatt

    2017-12-01

    Full Text Available Penetration testing is very important technique to find vulnerabilities in commercial networks. There are various techniques for ethical hacking via penetration testing. This report explains a white hat hacker approach of penetration testing. I have performed this test on private network where three PCs are connected through LAN via switch and without firewall. This network is not connected with Internet. All the PCs have windows operating system. The attacker host has windows server 2003 with Service Pack1 second host has windows XP with Service Pack 2 and third host has windows 2000 with service pack 4.

  11. State of the art on phase change material slurries

    International Nuclear Information System (INIS)

    Youssef, Ziad; Delahaye, Anthony; Huang Li; Trinquet, François; Fournaison, Laurence; Pollerberg, Clemens; Doetsch, Christian

    2013-01-01

    Highlights: ► A bibliographic study on PCM slurries. ► Clathrate Hydrate slurry, Microencapsulated PCM Slurry, shape-stabilized PCM slurries and Phase Change Material Emulsions. ► Formation, thermo-physical, rheological, heat transfers properties and applications of these four PCS systems. ► The use of thermal energy storage and distribution based on PCM slurries can improve the refrigerating machine performances. - Abstract: The interest in using phase change slurry (PCS) media as thermal storage and heat transfer fluids is increasing and thus leading to an enhancement in the number of articles on the subject. In air-conditioning and refrigeration applications, PCS systems represent a pure benefit resulting in the increase of thermal energy storage capacity, high heat transfer characteristics and positive phase change temperatures which can occur under low pressures. Hence, they allow the increase of energy efficiency and reduce the quantity of thermal fluids. This review describes the formation, thermo-physical, rheological, heat transfer properties and applications of four PCS systems: Clathrate hydrate slurry (CHS), Microencapsulated Phase Change Materials Slurry (MPCMS), shape-stabilized PCM slurries (SPCMSs) and Phase Change Material Emulsions (PCMEs). It regroups a bibliographic summary of important information that can be very helpful when such systems are used. It also gives interesting and valuable insights on the choice of the most suitable PCS media for laboratory and industrial applications.

  12. Expected and Realized Costs and Benefits from Implementing Product Configuration Systems

    DEFF Research Database (Denmark)

    Edwards, Kasper

    2010-01-01

    Product configuration systems (PCS) are a technology well suited for mass customization and support the task of configuring the product to the individual customer’s needs. PCS are at the same time complex software systems that may be tailored to solve a variety of problems for a firm, e.......g. supporting the quotation process or validating the structure of a product. This paper reports findings from a study of 12 Danish firms, which at the time of the study have implemented or are in the process of implementing product configuration systems. 12 costs and 12 benefits are identified in literature...... organization. It is observed that product configuration projects are treated as simple technical projects although they should be regarded as organizational change projects....

  13. Analysis and simulation of mobile air conditioning system coupled with engine cooling system

    International Nuclear Information System (INIS)

    Qi, Zhao-gang; Chen, Jiang-ping; Chen, Zhi-jiu

    2007-01-01

    Many components of the mobile air conditioning system and engine cooling system are closely interrelated and make up the vehicle climate control system. In the present paper, a vehicle climate control system model including air conditioning system and engine cooling system has been proposed under different operational conditions. All the components have been modeled on the basis of experimental data. Based on the commercial software, a computer simulation procedure of the vehicle climate control system has been developed. The performance of the vehicle climate control system is simulated, and the calculational data have good agreement with experimental data. Furthermore, the vehicle climate control simulation results have been compared with an individual air conditioning system and engine cooling system. The influences between the mobile air conditioning system and the engine cooling system are discussed

  14. Estimation on the Pressure Loss of the Conceptual Primary Cooling System and Design of the Primary Cooling Pump for a Research Reactor

    International Nuclear Information System (INIS)

    Seo, Kyoung Woo; Oh, Jae Min; Park, Jong Hark; Chae, Hee Taek; Seo, Jae Kwang; Park, Cheon Tae; Yoon, Ju Hyeon; Lee, Doo Jeong

    2009-01-01

    A new conceptual primary cooling system (PCS) for a research reactor has been designed for an adequate cooling to the reactor core which has various powers ranging from 30MW through 80MW. The developed primary cooling system consisted of decay tanks, pumps, heat exchangers, vacuum breakers, some isolation and check valves, connection piping, and instruments. Because the system flow rate should be determined by the thermal hydraulic design analysis for the core, the heads to design the primary cooling pumps (PCPs) in a PCS will be estimated by the variable system flow rates. The heads of the part of a research reactor vessel was evaluated by the previous study. The various pressure losses of the PCS can be calculated by the dimensional analysis of the pipe flow and the head loss coefficient of the components. The purpose of this research is to estimate the various pressure losses and to design the PCPs

  15. RAMI analysis for DEMO HCPB blanket concept cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Dongiovanni, Danilo N., E-mail: danilo.dongiovanni@enea.it [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati (Italy); Pinna, Tonio [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati (Italy); Carloni, Dario [KIT, Institute of Neutron Physics and Reactor Technology (INR) – KIT (Germany)

    2015-10-15

    Highlights: • RAMI (reliability, availability, maintainability and inspectability) preliminary assessment for HCPB blanket concept cooling system. • Reliability block diagram (RBD) modeling and analysis for HCPB primary heat transfer system (PHTS), coolant purification system (CPS), pressure control system (PCS), and secondary cooling system. • Sensitivity analysis on system availability performance. • Failure models and repair models estimated on the base of data from the ENEA fusion component failure rate database (FCFRDB). - Abstract: A preliminary RAMI (reliability, availability, maintainability and inspectability) assessment for the HCPB (helium cooled pebble bed) blanket cooling system based on currently available design for DEMO fusion power plant is presented. The following sub-systems were considered in the analysis: blanket modules, primary cooling loop including pipework and steam generators lines, pressure control system (PCS), coolant purification system (CPS) and secondary cooling system. For PCS and CPS systems an extrapolation from ITER Test Blanket Module corresponding systems was used as reference design in the analysis. Helium cooled pebble bed (HCPB) system reliability block diagrams (RBD) models were implemented taking into account: system reliability-wise configuration, operating schedule currently foreseen for DEMO, maintenance schedule and plant evolution schedule as well as failure and corrective maintenance models. A simulation of plant activity was then performed on implemented RBDs to estimate plant availability performance on a mission time of 30 calendar years. The resulting availability performance was finally compared to availability goals previously proposed for DEMO plant by a panel of experts. The study suggests that inherent availability goals proposed for DEMO PHTS system and Tokamak auxiliaries are potentially achievable for the primary loop of the HCPB concept cooling system, but not for the secondary loop. A

  16. Utilization of Solar Energy for Air Conditioning System

    Directory of Open Access Journals (Sweden)

    Sutikno Juwari Purwo

    2018-01-01

    Full Text Available The purposes of this research are to do a system simulation of air conditioning utilizing solar energy with single effect absorption refrigeration method, analyze the coefficient of performance (COP for each absorbent-refrigerant variable and compare the effectivity of every absorbent-refrigerant variable used. COP is a constant that denotes the effeciency of a refrigeration system, that is ratio of work or useful output to the amount of work or energy input. The higher the number of COP, the more efficient the system is. Absorbent-refrigerant (working fluids variables used in this research depend on its chemical and thermodynamics properties. Steps in this research are including data collection and tabulation from literature and do a simulation of air conditioning system both commercial air conditioning system (using electrical energy and solar energy air conditioning system with Aspen Plus software. Next, run the simulation for each working fluid variables used and calculate the COP for each variable. Subsequently, analyze and compare the effectivity of all variables used from COP value and economical point of view with commercial air conditioning system. From the result of the simulation, can be concluded that solar air conditioning can achieve 98,85 % of energy savings than commercial air conditioning. Furthermore, from the calculation of COP, the highest COP value is achieved by solar conditioning system with LiNO3-NH3 as working fluid where 55% of the composition is the refrigerant and 45% of absorbent.

  17. A RADIANT AIR-CONDITIONING SYSTEM USING SOLAR-DRIVEN

    Directory of Open Access Journals (Sweden)

    S. A. ABDALLA

    2006-12-01

    Full Text Available Every air-conditioning system needs some fresh air to provide adequate ventilation air required to remove moisture, gases like ammonia and hydrogen sulphide, disease organisms, and heat from occupied spaces. However, natural ventilation is difficult to control because urban areas outside air is often polluted and cannot be supplied to inner spaces before being filtered. Besides the high electrical demand of refrigerant compression units used by most air-conditioning systems, and fans used to transport the cool air through the thermal distribution system draw a significant amount of electrical energy in comparison with electrical energy used by the building thermal conditioning systems. Part of this electricity heats the cooled air; thereby add to the internal thermal cooling peak load. In addition, refrigerant compression has both direct and indirect negative effects on the environment on both local and global scales. In seeking for innovative air-conditioning systems that maintain and improve indoor air quality under potentially more demanding performance criteria without increasing environmental impact, this paper presents radiant air-conditioning system which uses a solar-driven liquid desiccant evaporative cooler. The paper describes the proposed solar-driven liquid desiccant evaporative cooling system and the method used for investigating its performance in providing cold water for a radiant air-conditioning system in Khartoum (Central Sudan. The results of the investigation show that the system can operate in humid as well as dry climates and that employing such a system reduces air-conditioning peak electrical demands as compared to vapour compression systems.

  18. Fungal colonization of air-conditioning systems

    Directory of Open Access Journals (Sweden)

    Ljaljević-Grbić Milica

    2008-01-01

    Full Text Available Fungi have been implicated as quantitatively the most important bioaerosol component of indoor air associated with contaminated air-conditioning systems. rarely, indoor fungi may cause human infections, but more commonly allergenic responses ranging from pneumonitis to asthma-like symptoms. From all air conditioner filters analyzed, 16 fungal taxa were isolated and identified. Aspergillus fumigatus causes more lethal infections worldwide than any other mold. Air-conditioning filters that adsorb moisture and volatile organics appear to provide suitable substrates for fungal colonization. It is important to stress that fungal colonization of air-conditioning systems should not be ignored, especially in hospital environments.

  19. Framework for Integrating Science Data Processing Algorithms Into Process Control Systems

    Science.gov (United States)

    Mattmann, Chris A.; Crichton, Daniel J.; Chang, Albert Y.; Foster, Brian M.; Freeborn, Dana J.; Woollard, David M.; Ramirez, Paul M.

    2011-01-01

    A software framework called PCS Task Wrapper is responsible for standardizing the setup, process initiation, execution, and file management tasks surrounding the execution of science data algorithms, which are referred to by NASA as Product Generation Executives (PGEs). PGEs codify a scientific algorithm, some step in the overall scientific process involved in a mission science workflow. The PCS Task Wrapper provides a stable operating environment to the underlying PGE during its execution lifecycle. If the PGE requires a file, or metadata regarding the file, the PCS Task Wrapper is responsible for delivering that information to the PGE in a manner that meets its requirements. If the PGE requires knowledge of upstream or downstream PGEs in a sequence of executions, that information is also made available. Finally, if information regarding disk space, or node information such as CPU availability, etc., is required, the PCS Task Wrapper provides this information to the underlying PGE. After this information is collected, the PGE is executed, and its output Product file and Metadata generation is managed via the PCS Task Wrapper framework. The innovation is responsible for marshalling output Products and Metadata back to a PCS File Management component for use in downstream data processing and pedigree. In support of this, the PCS Task Wrapper leverages the PCS Crawler Framework to ingest (during pipeline processing) the output Product files and Metadata produced by the PGE. The architectural components of the PCS Task Wrapper framework include PGE Task Instance, PGE Config File Builder, Config File Property Adder, Science PGE Config File Writer, and PCS Met file Writer. This innovative framework is really the unifying bridge between the execution of a step in the overall processing pipeline, and the available PCS component services as well as the information that they collectively manage.

  20. Feasibility evaluation of two solar cooling systems applied to a cuban hotel. Comparative analysis

    International Nuclear Information System (INIS)

    Díaz Torres, Yamile; Valdivia Nodal, Yarelis; Monteagudo Yanes, José Pedro; Miranda Torres, Yudit

    2016-01-01

    The article presents an analysis of technical and economic feasibility of using two configurations of solar cooling in a Cuban hotel. HVAC hybrid schemes are: a cooler of ice water vapor compression (chiller) interconnected in parallel with a smaller capacity chiller, first with a solar-powered absorption cooling system (SACS), and then with a photovoltaic cooling system(PSC). Both were simulated taking into account the weather conditions in the region, thermodynamic calculation methodologies and principles that govern these technologies. The results show that the use of these alternatives contributes to reducing energy consumption and the environmental impact of heating, ventilation and air conditioning systems (HVAC). Economic analysis highlights that PCS is more favorable than the SACS taking into account the cooling cost generation (CCG) but energy assessment indicates that SACS has higher thermal performance for the case study to which it is applied. (author)

  1. Evaluation of FSO System Availability in Haze Condition

    Science.gov (United States)

    Anis, A. A.; Rashidi, C. B. M.; Aljunid, S. A.; Rahman, A. K.

    2018-03-01

    In this paper, we proposed the evaluation of FSO system availability in haze condition. The atmospheric attenuation by weather conditions in the atmosphere as the most challenging problem of FSO system as the system performance is severely degraded and causing the signal optic to be transmitted poorly. The effects of haze condition on the performance of FSO system is stressed out and focused in this paper. From the evaluation of the analysis, designs of FSO system are proposed to obtain a system with improved link performance in haze conditions. The scattering coefficient and the atmospheric attenuation are determined using Beer’s Lambert equation. From the research, the link performance of the system is greatly improved using Design 2 with minimum BER of 10-127127 and maximu m Q Factor of 23.98. The FSO system using Design 2 has better performance compared to Design 1 in haze condition as the optical signals could penetrate the dense haze better without losing much optical power during the transmission to the scattering.

  2. Development of a high-performance control system by decentralization with reflective memory on QUEST

    International Nuclear Information System (INIS)

    Hasegawa, Makoto; Nakamura, Kazuo; Zushi, Hideki; Hanada, Kazuaki; Fujisawa, Akihide; Mitarai, Osamu; Tokunaga, Kazutoshi; Idei, Hiroshi; Nagashima, Yoshihiko; Kawasaki, Shoji; Nakashima, Hisatoshi; Higashijima, Aki

    2015-01-01

    Graphical abstract: - Highlights: • The plasma control system of QUEST is decentralized by a reflective memory. • The latency due to RFM transaction is 250 μs with the data sharing of 1 kB. • The time synchronization of systems is done by referring to its time difference. • Core occupancy due to RFM is usually 60%, and 90% intermittently. - Abstract: The plasma control system (PCS) of QUEST was a centralized system, which lost its scalability because of the overload imposed on its central processing unit (CPU) of the PCS, making it impossible to add new functions. Thus, the PCS is distributed into a main workstation (WS) and subsystem (SS) with a reflective memory (RFM) in order to share data between these systems so as to mitigate the load on each system. As a result, 128 double-precision floating-point numbers (DBLs) can be transferred from the SS to the WS with a maximum latency of 250 μs. The WS and the SS each have quad-core CPUs, and tasks are executed in parallel. Although one of the four cores is intermittently occupied by up to 90% by this transaction, the occupation is normally 60%. A time correction procedure is used to map the recorded data sets on the WS and the SS to a common time base by referring to the time difference between two systems.

  3. Development of a high-performance control system by decentralization with reflective memory on QUEST

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Makoto, E-mail: hasegawa@triam.kyushu-u.ac.jp [RIAM, Kyushu University, Kasuga, Fukuoka (Japan); Nakamura, Kazuo; Zushi, Hideki; Hanada, Kazuaki; Fujisawa, Akihide [RIAM, Kyushu University, Kasuga, Fukuoka (Japan); Mitarai, Osamu [Tokai University, Toroku, Kumamoto (Japan); Tokunaga, Kazutoshi; Idei, Hiroshi; Nagashima, Yoshihiko; Kawasaki, Shoji; Nakashima, Hisatoshi; Higashijima, Aki [RIAM, Kyushu University, Kasuga, Fukuoka (Japan)

    2015-10-15

    Graphical abstract: - Highlights: • The plasma control system of QUEST is decentralized by a reflective memory. • The latency due to RFM transaction is 250 μs with the data sharing of 1 kB. • The time synchronization of systems is done by referring to its time difference. • Core occupancy due to RFM is usually 60%, and 90% intermittently. - Abstract: The plasma control system (PCS) of QUEST was a centralized system, which lost its scalability because of the overload imposed on its central processing unit (CPU) of the PCS, making it impossible to add new functions. Thus, the PCS is distributed into a main workstation (WS) and subsystem (SS) with a reflective memory (RFM) in order to share data between these systems so as to mitigate the load on each system. As a result, 128 double-precision floating-point numbers (DBLs) can be transferred from the SS to the WS with a maximum latency of 250 μs. The WS and the SS each have quad-core CPUs, and tasks are executed in parallel. Although one of the four cores is intermittently occupied by up to 90% by this transaction, the occupation is normally 60%. A time correction procedure is used to map the recorded data sets on the WS and the SS to a common time base by referring to the time difference between two systems.

  4. Ventilation-air conditioning system

    International Nuclear Information System (INIS)

    Kubokoya, Takashi.

    1991-01-01

    Heretofore, in ventilation-air conditioning systems in a nuclear power plant, exhaust gases from each of the ventilation-air conditioning systems of a reactor building, a turbine building, a waste processing building are joined and they are released into atmosphere from the top of a high main exhaustion stack. In order to build such a high main exhaustion stack, a considerable construction cost is required and, in addition, there is a worry of lacking balance with surrounding scenery. Then, in the present invention, exhaust gases are heated by waste heat in a turbine during their introduction from the ventilation-air conditioning facility in the building of a power plant to the main exhaust stack. With such a constitution, since the exhaust gases are heated and their temperature is elevated, they uprise by natural convection when they are released from the top of the main exhaustion stack to the atmosphere. Accordingly, they are released to a level higher than the conventional case in view of the volume of the blower which sends the exhaust gases under pressure, to diffuse them to the atmosphere more sufficiently compared with a conventional case. Further, the height of the main exhaustion stack can be reduced, enabling to minimize the cost for moving the blower. (T.M.)

  5. The ITER Plasma Control System Simulation Platform

    International Nuclear Information System (INIS)

    Walker, M.L.; Ambrosino, G.; De Tommasi, G.; Humphreys, D.A.; Mattei, M.; Neu, G.; Rapson, C.J.; Raupp, G.; Treutterer, W.; Welander, A.S.; Winter, A.

    2015-01-01

    Highlights: • A development and test environment called PCSSP has been constructed for the ITER PCS. • A description of requirements and use cases, a final design and software architecture design, users guide, and a prototype implementation have been delivered. • The prototype implementation was demonstrated at IO in December of 2013. • PCSSP will be deployed for alpha testing to the IO, the development group, and selected other ITER partners upon completion of the next development phase. - Abstract: The Plasma Control System Simulation Platform (PCSSP) is a highly flexible, modular, time-dependent simulation environment developed primarily to support development of the ITER Plasma Control System (PCS). It has been under development since 2011 and is scheduled for first release to users in the ITER Organization (IO) and at selected additional sites in 2015. Modules presently implemented in PCSSP enable exploration of axisymmetric evolution and control, basic kinetic control, and tearing mode suppression. A basic capability for generation of control-relevant events is included, enabling study of exception handling in the PCS, continuous controllers, and PCS architecture. While the control design focus of PCSSP applications tends to require only a moderate level of accuracy and complexity in modules, more complex codes can be embedded or connected to access higher accuracy if needed. This paper describes the background and motivation for PCSSP, provides an overview of the capabilities, architecture, and features of PCSSP, and discusses details of the PCSSP vision and its intended goals and application. Completed work, including architectural design, prototype implementation, reference documents, and IO demonstration of PCSSP, is summarized and example use of PCSSP is illustrated. Near-term high-level objectives are summarized and include preparation for release of an “alpha” version of PCSSP and preparation for the next development phase. High

  6. The ITER Plasma Control System Simulation Platform

    Energy Technology Data Exchange (ETDEWEB)

    Walker, M.L., E-mail: walker@fusion.gat.com [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Ambrosino, G.; De Tommasi, G. [CREATE/Università di Napoli Federico II, Napoli (Italy); Humphreys, D.A. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Mattei, M. [CREATE/Seconda Università di Napoli, Napoli (Italy); Neu, G.; Rapson, C.J.; Raupp, G.; Treutterer, W. [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Welander, A.S. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Winter, A. [ITER Organization, Route de Vinon-sur-Verdon, 13115 St. Paul-lez-Durance (France)

    2015-10-15

    Highlights: • A development and test environment called PCSSP has been constructed for the ITER PCS. • A description of requirements and use cases, a final design and software architecture design, users guide, and a prototype implementation have been delivered. • The prototype implementation was demonstrated at IO in December of 2013. • PCSSP will be deployed for alpha testing to the IO, the development group, and selected other ITER partners upon completion of the next development phase. - Abstract: The Plasma Control System Simulation Platform (PCSSP) is a highly flexible, modular, time-dependent simulation environment developed primarily to support development of the ITER Plasma Control System (PCS). It has been under development since 2011 and is scheduled for first release to users in the ITER Organization (IO) and at selected additional sites in 2015. Modules presently implemented in PCSSP enable exploration of axisymmetric evolution and control, basic kinetic control, and tearing mode suppression. A basic capability for generation of control-relevant events is included, enabling study of exception handling in the PCS, continuous controllers, and PCS architecture. While the control design focus of PCSSP applications tends to require only a moderate level of accuracy and complexity in modules, more complex codes can be embedded or connected to access higher accuracy if needed. This paper describes the background and motivation for PCSSP, provides an overview of the capabilities, architecture, and features of PCSSP, and discusses details of the PCSSP vision and its intended goals and application. Completed work, including architectural design, prototype implementation, reference documents, and IO demonstration of PCSSP, is summarized and example use of PCSSP is illustrated. Near-term high-level objectives are summarized and include preparation for release of an “alpha” version of PCSSP and preparation for the next development phase. High

  7. Status of the CMS Detector Control System

    CERN Document Server

    Bauer, Gerry; Bouffet, Olivier; Bowen, Matthew; Branson, James G; Bukowiec, Sebastian; Ciganek, Marek; Cittolin, Sergio; Jose Antonio Coarasa; Deldicque, Christian; Dobson, Marc; Dupont, Aymeric; Erhan, Samim; Flossdorf, Alexander; Gigi, Dominique; Glege, Frank; Gomez-Reino, Robert; Hartl, Christian; Hegeman, Jeroen; Holzner, André; Yi Ling Hwong; Masetti, Lorenzo; Meijers, Frans; Meschi, Emilio; Mommsen, Remigius K; O'Dell, Vivian; Orsini, Luciano; Paus, Christoph; Petrucci, Andrea; Pieri, Marco; Polese, Giovanni; Racz, Attila; Raginel, Olivier; Sakulin, Hannes; Sani, Matteo; Schwick, Christoph; Shpakov, Dennis; Simon, Michal; Andrei Cristian Spataru; Sumorok, Konstanty

    2012-01-01

    The Compact Muon Solenoid (CMS) is a CERN multi-purpose experiment that exploits the physics of the Large Hadron Collider (LHC). The Detector Control System (DCS) ensures a safe, correct and efficient experiment operation, contributing to the recording of high quality physics data. The DCS is programmed to automatically react to the LHC operational mode. CMS sub-detectors' bias voltages are set depending on the machine mode and particle beam conditions. An operator provided with a small set of screens supervises the system status summarized from the approximately 6M monitored parameters. Using the experience of nearly two years of operation with beam the DCS automation software has been enhanced to increase the system efficiency by minimizing the time required by sub detectors to prepare for physics data taking. From the infrastructure point of view the DCS will be subject to extensive modifications in 2012. The current rack mounted control PCs will be exchanged by a redundant pair of DELL Blade systems. Thes...

  8. A fault tolerant system by using distributed RTOS

    International Nuclear Information System (INIS)

    Ge Yingan; Liu Songqiang; Wang Yanfang

    1999-01-01

    The author describes the design and implementation of a prototypal distributed fault tolerant system, which is developed under QNX RTOS by networking two standard PCs. By using a watchdog timer for error detection, the system can be tolerant for fail silent and transient fault of a single node

  9. Unexpected emergence of a Community of Practice when implementing Product Configuration Systems

    DEFF Research Database (Denmark)

    Edwards, Kasper; Møldrup, Morten

    2004-01-01

    of products. Sales staff copes by specializing in particular products and becomes increasingly fragmented. Product configuration systems (PCS) are a technology, which is designed to manage product variety by automating parts of the work performed by sales staff. PCS is also seen by management as a tool......Customers are increasingly demanding customised products tailored to their specific needs, and many firms are faced with the challenge of delivering such goods. Over time the number of product variants increases with consequences for sales staff, as they must know an increasingly larger number...

  10. A Semi-Preemptive Computational Service System with Limited Resources and Dynamic Resource Ranking

    Directory of Open Access Journals (Sweden)

    Fang-Yie Leu

    2012-03-01

    Full Text Available In this paper, we integrate a grid system and a wireless network to present a convenient computational service system, called the Semi-Preemptive Computational Service system (SePCS for short, which provides users with a wireless access environment and through which a user can share his/her resources with others. In the SePCS, each node is dynamically given a score based on its CPU level, available memory size, current length of waiting queue, CPU utilization and bandwidth. With the scores, resource nodes are classified into three levels. User requests based on their time constraints are also classified into three types. Resources of higher levels are allocated to more tightly constrained requests so as to increase the total performance of the system. To achieve this, a resource broker with the Semi-Preemptive Algorithm (SPA is also proposed. When the resource broker cannot find suitable resources for the requests of higher type, it preempts the resource that is now executing a lower type request so that the request of higher type can be executed immediately. The SePCS can be applied to a Vehicular Ad Hoc Network (VANET, users of which can then exploit the convenient mobile network services and the wireless distributed computing. As a result, the performance of the system is higher than that of the tested schemes.

  11. Air conditioning for data processing system areas

    Directory of Open Access Journals (Sweden)

    Hernando Camacho García

    1996-09-01

    Full Text Available The appropiate selection of air conditioners for data processing system areas requires the knowledge of the environmental desing conditions, the air conditioning systems succssfully used computer and the cooling loads to handle. This work contains information about a wide variety of systems designed for computer room applications. a complete example of calculation to determine the amount of heat to be removed for satisfactory operation, is also included.

  12. The design of remote discharge scenario management system on EAST

    Energy Technology Data Exchange (ETDEWEB)

    Chai, W.T, E-mail: wtchai@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); University of Science and Technology of China, Hefei, Anhui (China); Xiao, B.J [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); University of Science and Technology of China, Hefei, Anhui (China); Yuan, Q.P; Zhang, R.R. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China)

    2016-11-15

    Highlights: • The remote discharge scenario management system is established on EAST, it provides some useful function for operators to manage discharge scenarios and formulate discharge schedule. • Operators can use this system to formulate discharge schedule on account of it can electing optimal scenarios automatically. • The system is not only for local user but also for remote user. • In the future, we can combine with actual discharge data and data mining technology to acquire optimal configuration, which to generate expert database and guiding experiment. - Abstract: The discharge scenarios on EAST plasma control system (PCS), characterized by different waveform parameters and different hardware requirements, will need a systematic discharge scenario management system for remote and local operators, in order to optimize storage structure and rationally manage discharge time. The remote management of discharge scenarios will require extending the functionalities of the present PCS “future shot” and “next shot” modules. Taking advantage of database technique, the operators can acquire detail information of all discharge scenarios directly without PCS user interface and search the specified scenarios by key words. In addition, the system can elect optimal scenarios automatically based on discharge schedule and plasma pulse setting for later artificial selection. To this purpose, a new remote discharge scenario management system (RDSMS) basis for Web is being conceived on EAST. The system contains a database with functions of “user management”, “scenario verification”, “prepared scenario management”, “actual discharge scenario management” and “discharge schedule management”. This paper will present the relevant conceptual design and give an account of the test results for implementation on EAST discharges.

  13. The design of remote discharge scenario management system on EAST

    International Nuclear Information System (INIS)

    Chai, W.T; Xiao, B.J; Yuan, Q.P; Zhang, R.R.

    2016-01-01

    Highlights: • The remote discharge scenario management system is established on EAST, it provides some useful function for operators to manage discharge scenarios and formulate discharge schedule. • Operators can use this system to formulate discharge schedule on account of it can electing optimal scenarios automatically. • The system is not only for local user but also for remote user. • In the future, we can combine with actual discharge data and data mining technology to acquire optimal configuration, which to generate expert database and guiding experiment. - Abstract: The discharge scenarios on EAST plasma control system (PCS), characterized by different waveform parameters and different hardware requirements, will need a systematic discharge scenario management system for remote and local operators, in order to optimize storage structure and rationally manage discharge time. The remote management of discharge scenarios will require extending the functionalities of the present PCS “future shot” and “next shot” modules. Taking advantage of database technique, the operators can acquire detail information of all discharge scenarios directly without PCS user interface and search the specified scenarios by key words. In addition, the system can elect optimal scenarios automatically based on discharge schedule and plasma pulse setting for later artificial selection. To this purpose, a new remote discharge scenario management system (RDSMS) basis for Web is being conceived on EAST. The system contains a database with functions of “user management”, “scenario verification”, “prepared scenario management”, “actual discharge scenario management” and “discharge schedule management”. This paper will present the relevant conceptual design and give an account of the test results for implementation on EAST discharges.

  14. Quaternion Based Thermal Condition Monitoring System

    Science.gov (United States)

    Wong, Wai Kit; Loo, Chu Kiong; Lim, Way Soong; Tan, Poi Ngee

    In this paper, we will propose a new and effective machine condition monitoring system using log-polar mapper, quaternion based thermal image correlator and max-product fuzzy neural network classifier. Two classification characteristics namely: peak to sidelobe ratio (PSR) and real to complex ratio of the discrete quaternion correlation output (p-value) are applied in the proposed machine condition monitoring system. Large PSR and p-value observe in a good match among correlation of the input thermal image with a particular reference image, while small PSR and p-value observe in a bad/not match among correlation of the input thermal image with a particular reference image. In simulation, we also discover that log-polar mapping actually help solving rotation and scaling invariant problems in quaternion based thermal image correlation. Beside that, log-polar mapping can have a two fold of data compression capability. Log-polar mapping can help smoother up the output correlation plane too, hence makes a better measurement way for PSR and p-values. Simulation results also show that the proposed system is an efficient machine condition monitoring system with accuracy more than 98%.

  15. Hacking control systems, switching lights off!

    CERN Multimedia

    Computer Security Team

    2013-01-01

    Have you ever heard about “Stuxnet”? “Stuxnet” was a very sophisticated cyber-attack against the Iranian nuclear programme. Like in a spy movie, the attackers infiltrated the uranium enrichment plant at Natanz, arranged for infected USB sticks to be inserted into local PCs, and then the USB viruses did the rest.   Not only did the virus employ four distinct - so far unknown - weaknesses in the Windows operating system, but each weakness could have been sold on the underground market for up to $250,000 each. The virus was targeted to disrupt Iran's uranium production. At first, it scanned the infected PCs for dedicated SCADA (Supervisory Control and Data Acquisition) software from Siemens. Once the virus hit upon that software, it tried to identify any control system components, i.e. so-called PLCs (programmable logic controllers), attached to that PC. If the PLC matched a certain brand (Siemens S7) and configuration, the virus downloaded additi...

  16. High-Quality Learning Environments for Engineering Design: Using Tablet PCs and Guidelines from Research on How People Learn

    Directory of Open Access Journals (Sweden)

    Enrique Palou

    2012-04-01

    Full Text Available A team of several faculty members and graduate students at Universidad de las Amricas Puebla is improving engineering design teaching and learning by creating richer learning environments that promote an interactive classroom while integrating formative assessment into classroom practices by means of Tablet PCs and associated technologies. Learning environments that are knowledge-, learner-, community-, and assessment-centered as highlighted by the How People Learn framework, have been developed. To date, the redesign of the undergraduate course entitled Introduction to Engineering Design has signicantly (p<0.05 increased student participation; formative assessment and feedback are more common and rapid; and instructors are utilizing the information gained through real-time formative assessments to tailor instruction to meet student needs. Particularly important have been opportunities to make student thinking visible and to give them chances to revise, as well as opportunities for "what if" thinking.

  17. Changing tides: increasing evidence to embrace a patient classification system.

    Science.gov (United States)

    Malloch, Kathy

    2012-01-01

    The effective use of a patient classification system (PCS) in a way that provides value to all health care organizations has yet to be realized given the challenging developmental pathway of these systems. As the science and technology of workforce management emerges along with evidence to support the relationships between nurse work and patient care needs, it is no longer appropriate to rely on systems that provide aggregated and minimal data to address the need for safer patient care and retention of nurses. Specificity about patient care needs in a valid and reliable PCS is essential on our pathway to improved resource utilization, improved decision making, integration of nurse cognitive and knowledge work, and management of variances from planned resource use. Advancements with technology, the ability to create and monitor equitable nurse-patient assignments, conceptual clarity, evidence, regulatory requirements, and professional role development point to a new receptiveness for PCSs.

  18. A PC based control system for the CERN ISOLDE separators

    International Nuclear Information System (INIS)

    Billinge, R.; Bret, A.; Deloose, I.; Pace, A.; Shering, G.

    1992-01-01

    The control system of the two isotope separators of CERN, named ISOLDE, is being completely redesigned with the goal of having a flexible, high performance and inexpensive system. A new architecture that makes heavy use of the commercial software and hardware available for the huge Personal Computer (PC) market is being implemented on the 1700 geographically distributed control channels of the separators. 8 MS-DOS TM i386-based PCs with about 80 acquisition/control boards are used to access the equipments while 3 other PCs running Microsoft Windows TM and Microsoft Excel TM are used as consoles, the whole through a Novell TM Local Area Network with a PC Disk Server used as a database. This paper describes the interesting solutions found and discusses the reduced programming work load and costs that are expected to build the system before the start of the separators in March 1992. (author)

  19. Product configuration system and its impact on product’s life cycle complexity

    DEFF Research Database (Denmark)

    Myrodia, Anna; Kristjansdottir, Katrin; Shafiee, Sara

    2016-01-01

    The purpose of this paper is to identify areas throughout a product's lifecycle processes where complexity can be reduced by implementing a product configuration system (PCS). As discussed in the literature, several benefits are realized by using a PCS in terms of product and process standardizat...... for the company in several life cycle processes....... standardization. This also leads to control and reduce of complexity both in products and processes. To this end, this research attempts to quantify and assess these benefits and is supported by empirical evidence. A case study of an engineering company is used and the results indicate significant improvements...

  20. Increased accuracy of cost-estimation using product configuration systems

    DEFF Research Database (Denmark)

    Rasmussen, Jeppe Bredahl; Hvam, Lars; Mortensen, Niels Henrik

    This article describes an approach for utilizing Product Configuration Systems (PCS) for quantifying project costs in project-based companies. It presents a case study demonstrating a method of quantifying costs in a way that makes it possible to configure cost- and time estimates. Piecework costs......, material costs and sub-supplier costs are used as principle cost elements and linked to structural and process elements to facilitate configuration. The cost data are used by the PCS to generate fast and accurate cost-estimates, quotations, time estimates and cost summaries. The described cost...... quantification principles have been used in a Scandinavian SME (Small and Medium-sized Enterprise) since the 90’s, but have since 2011 been adopted to be used in a configuration system. A longitudinal case study was conducted to compare cost and time-estimation accuracy before and after implementation. We...

  1. Economic analysis of condition monitoring systems for offshore wind turbine sub-systems

    DEFF Research Database (Denmark)

    May, Allan; MacMillan, David; Thöns, Sebastian

    2015-01-01

    The use of condition monitoring systems on offshore wind turbines has increased dramatically in recent times. However, their use is mostly restricted to vibration based monitoring systems for the gearbox, generator and drive train. A survey of commercially available condition monitoring systems...... year life cycle. The model uses Hidden Markov Models to represent both the actual system state and the observed condition monitoring state. The CM systems are modelled to include reduced failure types, false alarms, detection rates and 6 month failure warnings. The costs for system failures are derived...... and their associated costs has been completed for the blades, drive train, tower and foundation. This paper considers what value can be obtained from integrating these additional systems into the maintenance plan. This is achieved by running simulations on an operations and maintenance model for a wind farm over a 20...

  2. The optimum operating conditions of the phased double-rotor facility at the ET-RR-1 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Naguib, K.; Habib, N.; Wahba, M.; Kilany, M.; Adib, M. [National Research Centre, Cairo (Egypt). Reactor and Neutron Physics Dept.

    1997-02-07

    A pulsed neutron polyenergetic thermal beam at ET-RR-1 is produced by a phased double-rotor facility. One of the rotors has two diametrically opposite curved slots, while the second is designed to operate as a rotating collimator. The dimensions of the phased rotating collimator are selected to match the curved slot rotor. The calculated collimator transmissions at different operating conditions are found to be in good agreement with the experimental ones. The optimum operating conditions of the double-rotor facility are deduced. The calculations were carried out using a computer program RCOL. The RCOL was designed in FORTRAN-77 to operate on PCs. (author).

  3. The optimum operating conditions of the phased double-rotor facility at the ET-RR-1 reactor

    International Nuclear Information System (INIS)

    Naguib, K.; Habib, N.; Wahba, M.; Kilany, M.; Adib, M.

    1997-01-01

    A pulsed neutron polyenergetic thermal beam at ET-RR-1 is produced by a phased double-rotor facility. One of the rotors has two diametrically opposite curved slots, while the second is designed to operate as a rotating collimator. The dimensions of the phased rotating collimator are selected to match the curved slot rotor. The calculated collimator transmissions at different operating conditions are found to be in good agreement with the experimental ones. The optimum operating conditions of the double-rotor facility are deduced. The calculations were carried out using a computer program RCOL. The RCOL was designed in FORTRAN-77 to operate on PCs. (author)

  4. Federal Emergency Management Information System (FEMIS) System Administration Guide for FEMIS Version 1.4.6

    Energy Technology Data Exchange (ETDEWEB)

    Arp, J.A.; Bower, J.C.; Burnett, R.A.; Carter, R.J.; Downing, T.R.; Fangman, P.M.; Gerhardstein, L.H.; Homer, B.J.; Johnson, D.M.; Johnson, R.L.; Johnson, S.M.; Loveall, R.M.; Martin, T.J.; Millard, W.D.; Schulze, S.A.; Stoops, L.R.; Tzemos, S.; Wood, B.M.

    1999-06-29

    The Federal Emergency Management Information System (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the U.S. Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are corrected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication data distribution and notification functionality necessary to operate FEMIS in a networked, client/server environment.

  5. HEADPLAY Personal Cinema System Facilitates Intravenous Cannulation in Children: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Evangeline Lim

    2013-01-01

    Full Text Available HEADPLAY personal cinema system (PCS is a portable visual headset/visor through which movie clips may be viewed. We studied the use of HEADPLAY PCS as a distraction tool in facilitating intravenous cannulation in children undergoing anaesthesia. 60 children were enrolled into the study and randomized into 2 groups. EMLA local anaesthetic cream was used to reduce the pain associated with intravenous cannulation. Children in group 1 wore the HEADPLAY visor whereas children in group 2 were subject to conventional distraction therapy. Children were asked to rate their anxiety, pain, and satisfaction scores after intravenous cannulation. Periprocedural anxiety was also determined using the modified Yale Preoperative Anxiety Scale (mYPAS. There were no statistically significant differences in terms of pain and anxiety scores between the 2 groups. Although the satisfaction score of the children in the HEADPLAY PCS group was marginally higher compared to the conventional group, this did not hit statistical significance. 86.6% of children in group 1 reported that they would want to use the visor again for their next intravenous cannulation. We conclude that HEADPLAY PCS is a distraction tool that is acceptable to most children and can contribute towards satisfaction of the intravenous cannulation process in children.

  6. The Effect of a Ceramic Coating on Zr Alloys in Terms of Corrosion

    International Nuclear Information System (INIS)

    Kim, Kyung Tae; Park, Kwangheon; Park, Joo Young; Noh, Seonho

    2013-01-01

    It is very important to analyze fuel cladding mechanical properties. Polycarbosilane(PCS) is a special ceramic whose protection films inhibit oxidation chemical resistance and strength at high temperatures. The PCS coating was carried out under various reaction conditions. The results showed that the supercritical process tries to moderate oxidation conditions such as temperature, time, and solution amount. In this study, we used specimens of the types currently used in nuclear reactors(zry-4, zirlo), as well as their corresponding coating specimens (PCS, CrN and CrN + Tungsten), to conduct an oxidation analysis four type of conditions(water, LiOH, LiOH + Boron, and steam) over the course of a month. CrN coating layers were successfully formed with good protection on metal surface and without any defect. CrN coated specimen formed protective coating layers, inhibiting oxidized layers. However, both Zry-4 and Zirlo PCS coated specimens experience suddenly high oxidation rates in all kinds of conditions. As a result, the specimens supported the acceleration of oxidation by PCS

  7. Consistency conditions for data base systems: a new problem of systems analysis

    International Nuclear Information System (INIS)

    Schlageter, G.

    1976-01-01

    A data base can be seen as a model of a system in the real world. During the systems analysis conditions must be derived which guarantee a close correspondence between the real system and the data base. These conditions are called consistency constraints. The notion of consistency is analyzed; different types of consistency constraints are presented. (orig.) [de

  8. Conditional density matrix: systems and subsystems in quantum mechanics

    International Nuclear Information System (INIS)

    Belokurov, V.V.; Khrustalev, O.A.; Sadovnichij, V.A.; Timofeevskaya, O.D.

    2003-01-01

    A new quantum mechanical notion - Conditional Density Matrix - is discussed and is applied to describe some physical processes. This notion is a natural generalization of von Neumann density matrix for such processes as divisions of quantum systems into subsystems and reunifications of subsystems into new joint systems. Conditional Density Matrix assigns a quantum state to a subsystem of a composite system on condition that another part of the composite system is in some pure state

  9. Passive containment system in high earthquake motion

    International Nuclear Information System (INIS)

    Kleimola, F.W.; Falls, O.B. Jr.

    1977-01-01

    High earthquake motion necessitates major design modifications in the complex of plant structures, systems and components in a nuclear power plant. Distinctive features imposed by seismic category, safety class and quality classification requirements for the high seismic ground acceleration loadings significantly reflect in plant costs. The design features in the Passive Containment System (PCS) responding to high earthquake ground motion are described

  10. Summary of the third control system cyber-security (CS)2/HEP workshop

    International Nuclear Information System (INIS)

    Lueders, S.

    2012-01-01

    Over the last decade modern accelerator and experiment control systems have increasingly been based on commercial-off-the-shelf products (VME crates, programmable logic controllers (PLCs), supervisory control and data acquisition (SCADA) systems, etc.), on Windows or Linux PCs, and on communication infrastructures using Ethernet and TCP/IP. Despite the benefits coming with this (r)evolution, new vulnerabilities are inherited, too: Worms and viruses spread within seconds via the Ethernet cable, and attackers are becoming interested in control systems. The Stuxnet worm of 2010 against a particular Siemens PLC is a unique example for a sophisticated attack against control systems. Unfortunately, control PCs cannot be patched as fast as office PCs. Even worse, vulnerability scans at CERN using standard IT tools have shown that commercial automation systems lack fundamental security precautions: Some systems crashed during the scan, others could easily be stopped or their process data being altered. The third (CS)2/HEP workshop was intended to raise awareness; exchange good practices, ideas, and implementations; discuss what works and what not as well as their pros and cons; report on security events, lessons learned and successes; and update on progresses made at HEP laboratories around the world in order to secure control systems. It appears that deploying a 'Defense-in-depth approach is mandatory and corresponds to good practice while the full compliance to ISO-27000 standard is definitely both an ultimate goal and a very difficult challenge. There was a broad consensus to state that developing a 'security culture' among the players whatever they are: system experts, administrators, vendors or operators is the first step to do

  11. Necessary conditions for super-integrability of Hamiltonian systems

    Energy Technology Data Exchange (ETDEWEB)

    Maciejewski, Andrzej J. [Institute of Astronomy, University of Zielona Gora, Podgorna 50, PL-65-246 Zielona Gora (Poland)], E-mail: maciejka@astro.ia.uz.zgora.pl; Przybylska, Maria [Torun Centre for Astronomy, N. Copernicus University, Gagarina 11, PL-87-100 Torun (Poland)], E-mail: maria.przybylska@astri.uni.torun.pl; Yoshida, Haruo [National Astronomical Observatory, 2-21-1 Osawa, Mitaka, 181-8588 Tokyo (Japan)], E-mail: h.yoshida@nao.ac.jp

    2008-08-18

    We formulate a general theorem which gives a necessary condition for the maximal super-integrability of a Hamiltonian system. This condition is expressed in terms of properties of the differential Galois group of the variational equations along a particular solution of the considered system. An application of this general theorem to natural Hamiltonian systems of n degrees of freedom with a homogeneous potential gives easily computable and effective necessary conditions for the super-integrability. To illustrate an application of the formulated theorems, we investigate: three known families of integrable potentials, and the three body problem on a line.

  12. Surface free energy for systems with integrable boundary conditions

    International Nuclear Information System (INIS)

    Goehmann, Frank; Bortz, Michael; Frahm, Holger

    2005-01-01

    The surface free energy is the difference between the free energies for a system with open boundary conditions and the same system with periodic boundary conditions. We use the quantum transfer matrix formalism to express the surface free energy in the thermodynamic limit of systems with integrable boundary conditions as a matrix element of certain projection operators. Specializing to the XXZ spin-1/2 chain we introduce a novel 'finite temperature boundary operator' which characterizes the thermodynamical properties of surfaces related to integrable boundary conditions

  13. Air conditioning system with supplemental ice storing and cooling capacity

    Science.gov (United States)

    Weng, Kuo-Lianq; Weng, Kuo-Liang

    1998-01-01

    The present air conditioning system with ice storing and cooling capacity can generate and store ice in its pipe assembly or in an ice storage tank particularly equipped for the system, depending on the type of the air conditioning system. The system is characterized in particular in that ice can be produced and stored in the air conditioning system whereby the time of supplying cooled air can be effectively extended with the merit that the operation cycle of the on and off of the compressor can be prolonged, extending the operation lifespan of the compressor in one aspect. In another aspect, ice production and storage in great amount can be performed in an off-peak period of the electrical power consumption and the stored ice can be utilized in the peak period of the power consumption so as to provide supplemental cooling capacity for the compressor of the air conditioning system whereby the shift of peak and off-peak power consumption can be effected with ease. The present air conditioning system can lower the installation expense for an ice-storing air conditioning system and can also be applied to an old conventional air conditioning system.

  14. Computer Model to Estimate Reliability Engineering for Air Conditioning Systems

    International Nuclear Information System (INIS)

    Afrah Al-Bossly, A.; El-Berry, A.; El-Berry, A.

    2012-01-01

    Reliability engineering is used to predict the performance and optimize design and maintenance of air conditioning systems. Air conditioning systems are expose to a number of failures. The failures of an air conditioner such as turn on, loss of air conditioner cooling capacity, reduced air conditioning output temperatures, loss of cool air supply and loss of air flow entirely can be due to a variety of problems with one or more components of an air conditioner or air conditioning system. Forecasting for system failure rates are very important for maintenance. This paper focused on the reliability of the air conditioning systems. Statistical distributions that were commonly applied in reliability settings: the standard (2 parameter) Weibull and Gamma distributions. After distributions parameters had been estimated, reliability estimations and predictions were used for evaluations. To evaluate good operating condition in a building, the reliability of the air conditioning system that supplies conditioned air to the several The company's departments. This air conditioning system is divided into two, namely the main chilled water system and the ten air handling systems that serves the ten departments. In a chilled-water system the air conditioner cools water down to 40-45 degree F (4-7 degree C). The chilled water is distributed throughout the building in a piping system and connected to air condition cooling units wherever needed. Data analysis has been done with support a computer aided reliability software, this is due to the Weibull and Gamma distributions indicated that the reliability for the systems equal to 86.012% and 77.7% respectively. A comparison between the two important families of distribution functions, namely, the Weibull and Gamma families was studied. It was found that Weibull method performed for decision making.

  15. Secure Data Exchange in Environmental Health Monitoring System through Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Amang Sudarsono

    2016-04-01

    Full Text Available Recently, disseminating latest sensory information regarding the status of environmental health in the surroundings of human life is one of very important circumstances which must be known by everyone. These circumstances should be accessible at anytime and anywhere by everyone through any type of end-user devices, both fixed and mobile devices, i.e., Desktop PCs, Laptop PCs, and Smartphones. Wireless Sensor Network (WSN is one of the networks which deals with data sensors distribution from sensor nodes to the gateway node toward a Data Center Server. However, there is a big possibility for many adversaries to intercept and even manipulate data sensors crossing the network. Hence, a secure data sensor exchange in the system would be strongly desirable. In this research, we propose an environmental health conditions monitoring system through WSN and its implementation with considering secure data sensor exchange within the network and secure data sensor access. This work may contribute to support a part of smart cities and take in part the Internet of Thing (IoT technology. In our proposed system, we collect some environmental health information such as temperature, humidity, luminosity, noise, carbon monoxide (CO and carbon dioxide (CO2 from sensor nodes. We keep the confidentiality and integrity of transmitted data sensors propagating through IEEE802.15.4-based communication toward a gateway node. Further, the collected data sensors in the gateway are synchronized to the Data Center Server through a secure TCP/IP connection for permanently storing. At anytime and anywhere, only legitimated users who successfully pass-through an attribute-based authentication system are able to access the data sensors.

  16. The pCS20 PCR assay for Ehrlichia ruminantium does not cross-react with the novel deer ehrlichial agent found in white-tailed deer in the United States of America

    Directory of Open Access Journals (Sweden)

    S.M. Mahan

    2004-11-01

    Full Text Available White-tailed deer are susceptible to heartwater (Ehrlichia [Cowdria] ruminantium infection and are likely to suffer high mortality if the disease spreads to the United States. It is vital, therefore, to validate a highly specific and sensitive detection method for E. ruminantium infection that can be reliably used in testing white-tailed deer, which are reservoirs of antigenically or genetically related agents such as Ehrlichia chaffeensis, Anaplasma (Ehrlichia phagocytophilum (HGE agent and Ehrlichia ewingii. Recently, a novel but as yet unnamed ehrlichial species, the white-tailed deer ehrlichia (WTDE, has been discovered in deer populations in the United States. Although the significance of WTDE as a pathogen is unknown at present, it can be distinguished from other Ehrlichia spp. based on 16S rRNA gene sequence analysis. In this study it was differentiated from E. ruminantium by the use of the pCS20 PCR assay which has high specificity and sensitivity for the detection of E. ruminantium. This assay did not amplify DNA from the WTDE DNA samples isolated from deer resident in Florida, Georgia and Missouri, but amplified the specific 279 bp fragment from E. ruminantium DNA. The specificity of the pCS20 PCR assay for E. ruminantium was confirmed by Southern hybridization. Similarly, the 16S PCR primers (nested that amplify a specific 405-412 bp fragment from the WTDE DNA samples, did not amplify any product from E. ruminantium DNA. This result demonstrates that it would be possible to differentiate between E. ruminantium and the novel WTDE agent found in white tailed deer by applying the two respective PCR assays followed by Southern hybridizations. Since the pCS20 PCR assay also does not amplify any DNA products from E. chaffeensis or Ehrlichia canis DNA, it is therefore the method of choice for the detection of E. ruminantium in these deer and other animal hosts.

  17. Ventilation and air-conditioning system for PWR nuclear power plant

    International Nuclear Information System (INIS)

    Ohmoto, Kenji

    1987-01-01

    This report outlines the ventilation and air conditioning facilities for PWR nuclear power plant as well as design re-evaluation and optimization of ventilation and air-conditioning. The primary PWR installations are generally housed in the nuclear reactor building, auxiliary buildings and control building, which are equipped with their own ventilation and air-conditioning systems to serve for their specific purposes. A ventilation/air-conditioning system should be able to work effectively not only for maintaining the ordinary reactor operation but also for controlling the environmental temperature in the event of an accident. Designing of a ventilation/air-conditioning system relied on empirical data in the past, but currently it is performed based on information obtained from various analyses to optimize the system configuration and ventilation capacity. Design re-evaluation of ventilation/air-conditioning systems are conducted widely in various areas, aiming at the integration of safety systems, optimum combination of air-cooling and water-cooling systems, and optimization of the ventilation rate for controlling the concentrations of radioactive substances in the atmosphere in the facilities. It is pointed out that performance evaluation of ventilation/air-conditioning systems, which has been conducted rather macroscopically, should be carried out more in detal in the future to determine optimum air streams and temperature distribution. (Nogami, K.)

  18. The condition monitoring system of turbine system components for nuclear power plants

    International Nuclear Information System (INIS)

    Ono, Shigetoshi

    2013-01-01

    The thermal and nuclear power plants have been imposed a stable supply of electricity. To certainly achieve this, we built the plant condition monitoring system based on the heat and mass balance calculation. If there are some performance changes on the turbine system components of their power plants, the heat and mass balance of the turbine system will change. This system has ability to detect the abnormal signs of their components by finding the changes of the heat and mass balance. Moreover we note that this system is built for steam turbine cycle operating with saturated steam conditions. (author)

  19. Asset Condition, Information Systems and Decision Models

    CERN Document Server

    Willett, Roger; Brown, Kerry; Mathew, Joseph

    2012-01-01

    Asset Condition, Information Systems and Decision Models, is the second volume of the Engineering Asset Management Review Series. The manuscripts provide examples of implementations of asset information systems as well as some practical applications of condition data for diagnostics and prognostics. The increasing trend is towards prognostics rather than diagnostics, hence the need for assessment and decision models that promote the conversion of condition data into prognostic information to improve life-cycle planning for engineered assets. The research papers included here serve to support the on-going development of Condition Monitoring standards. This volume comprises selected papers from the 1st, 2nd, and 3rd World Congresses on Engineering Asset Management, which were convened under the auspices of ISEAM in collaboration with a number of organisations, including CIEAM Australia, Asset Management Council Australia, BINDT UK, and Chinese Academy of Sciences, Beijing University of Chemical Technology, Chin...

  20. Lack of predictive power of trait fear and anxiety for conditioned pain modulation (CPM).

    Science.gov (United States)

    Horn-Hofmann, Claudia; Priebe, Janosch A; Schaller, Jörg; Görlitz, Rüdiger; Lautenbacher, Stefan

    2016-12-01

    In recent years the association of conditioned pain modulation (CPM) with trait fear and anxiety has become a hot topic in pain research due to the assumption that such variables may explain the low CPM efficiency in some individuals. However, empirical evidence concerning this association is still equivocal. Our study is the first to investigate the predictive power of fear and anxiety for CPM by using a well-established psycho-physiological measure of trait fear, i.e. startle potentiation, in addition to two self-report measures of pain-related trait anxiety. Forty healthy, pain-free participants (female: N = 20; age: M = 23.62 years) underwent two experimental blocks in counter-balanced order: (1) a startle paradigm with affective picture presentation and (2) a CPM procedure with hot water as conditioning stimulus (CS) and contact heat as test stimulus (TS). At the end of the experimental session, pain catastrophizing (PCS) and pain anxiety (PASS) were assessed. PCS score, PASS score and startle potentiation to threatening pictures were entered as predictors in a linear regression model with CPM magnitude as criterion. We were able to show an inhibitory CPM effect in our sample: pain ratings of the heat stimuli were significantly reduced during hot water immersion. However, CPM was neither predicted by self-report of pain-related anxiety nor by startle potentiation as psycho-physiological measure of trait fear. These results corroborate previous negative findings concerning the association between trait fear/anxiety and CPM efficiency and suggest that shifting the focus from trait to state measures might be promising.

  1. Uncommon combinations of ICD10-PCS or ICD-9-CM operative procedure codes account for most inpatient surgery at half of Texas hospitals.

    Science.gov (United States)

    O'Neill, Liam; Dexter, Franklin; Park, Sae-Hwan; Epstein, Richard H

    2017-09-01

    Recently, there has been interest in activity-based cost accounting for inpatient surgical procedures to facilitate "value based" analyses. Research 10-20years ago, performed using data from 3 large teaching hospitals, found that activity-based cost accounting was practical and useful for modeling surgeons and subspecialties, but inaccurate for individual procedures. We hypothesized that these older results would apply to hundreds of hospitals, currently evaluable using administrative databases. Observational study. State of Texas hospital discharge abstract data for 1st quarter of 2016, 4th quarter of 2015, 1st quarter of 2015, and 4th quarter of 2014. Discharged from an acute care hospital in Texas with at least 1 major therapeutic ("operative") procedure. Counts of discharges for each procedure or combination of procedures, classified by ICD-10-PCS or ICD-9-CM. At the average hospital, most surgical discharges were for procedures performed at most once a month at the hospital (54%, 95% confidence interval [CI] 51% to 55%). At the average hospital, approximately 90% of procedures were performed at most once a month at the hospital (93%, CI 93% to 94%). The percentages were insensitive to the quarter of the year. The percentages were 3% to 6% greater with ICD-10-PCS than for the superseded ICD 9 CM. There are many different procedure codes, and many different combinations of codes, relative to the number of different hospital discharges. Since most procedures at most hospitals are performed no more than once a month, activity-based cost accounting with a sample size sufficient to be useful is impractical for the vast majority of procedures, in contrast to analysis by surgeon and/or subspecialty. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Impact of the utilization of a product configuration system on product’s life cycle complexity

    DEFF Research Database (Denmark)

    Myrodia, Anna; Kristjansdottir, Katrin; Shafiee, Sara

    The purpose of this paper is to identify areas throughout a product’s lifecycle processes where complexity can be reduced by implementing a product configuration system (PCS). As discussed in the literature, several benefits are realized by using a PCS in terms of product and process standardizat...... for the company in several life cycle processes....... standardization. This also leads to control and reduce of complexity both in products and processes. To this end, this research attempts to quantify and assess these benefits and is supported by empirical evidence. A case study of an engineering company is used and the results indicate significant improvements...

  3. Conditional symmetries for systems of PDEs: new definitions and their application for reaction-diffusion systems

    International Nuclear Information System (INIS)

    Cherniha, Roman

    2010-01-01

    New definitions of Q-conditional symmetry for systems of PDEs are presented, which generalize the standard notation of non-classical (conditional) symmetry. It is shown that different types of Q-conditional symmetry of a system generate a hierarchy of conditional symmetry operators. A class of two-component nonlinear reaction-diffusion systems is examined to demonstrate the applicability of the definitions proposed and it is shown when different definitions of Q-conditional symmetry lead to the same operators.

  4. Impact of demographic and comorbid conditions on quality of life of hemodialysis patients: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Qusay Mohammed Mandoorah

    2014-01-01

    Full Text Available To assess the quality of life (QOL of Saudi Arabian patients undergoing hemo-dialysis (HD and to determine the impact of gender, age, education and comorbidities on the QOL of these patients, we conducted a cross-sectional study and used the short form-36 (SF-36 questionnaire, a generic instrument for measuring QOL. This questionnaire is composed of eight scales that summarize the physical component scale (PCS and mental component scale (MCS of health status. We calculated the PCS and MCS scores for each patient. We studied 205 HD patients (123 men; ages 18-75 years from the King Fahd General Hospital, Jeddah, Saudi Arabia. The mean SF-36 score was 59.4 ± 21.7 in men and 41.9 ± 20.9 in women (P <0.0001. Patients older than 60 years had the worst score (41.5 ± 21.2, followed by patients aged 40-59 years (53.6 ± 22.8; patients aged 18-39 years had the best SF-36 score (57.5 ± 22.5; P <0.0001. Education had a positive impact on QOL (P <0.0001, whereas comorbid conditions had a nega-tive impact. Peripheral vascular disease was associated with the worst outcome (SF-36 score, 40.4 ± 23.0; P <0.0001, followed by dyslipidemia (42.9 ± 22.4; P = 0.001 and diabetes mellitus (45.0 ± 22.0; P = 0.012. Among the comorbid conditions, hypertension was associated with the best SF-36 score (50.6 ± 22.7; P = 0.034. We conclude that old age, female gender, poor education and comorbid conditions have a negative impact on the QOL of HD patients in Saudi Arabia. These findings indicate a general need for social support for female patients on HD and early diagnosis and management of comorbid conditions.

  5. Center conditions and limit cycles for BiLienard systems

    Directory of Open Access Journals (Sweden)

    Jaume Gine

    2017-03-01

    Full Text Available In this article we study the center problem for polynomial BiLienard systems of degree n. Computing the focal values and using Grobner bases we find the center conditions for such systems for n=6. We also establish a conjecture about the center conditions for polynomial BiLienard systems of arbitrary degree.

  6. Analysis on a hybrid desiccant air-conditioning system

    International Nuclear Information System (INIS)

    Jia, C.X.; Dai, Y.J.; Wu, J.Y.; Wang, R.Z.

    2006-01-01

    Hybrid desiccant-assisted preconditioner and split cooling coil system, which combines the merits of moisture removal by desiccant and cooling coil for sensible heat removal, is a potential alternative to conventional vapor compression cooling systems. In this paper, experiments on a hybrid desiccant air-conditioning system, which is actually an integration of a rotary solid desiccant dehumidification and a vapor compression air-conditioning unit, had been carried out. It is found that, compared with the conventional VC (vapor compression) system, the hybrid desiccant cooling system economizes 37.5% electricity powers when the process air temperature and relative humidity are maintained at 30 o C, and 55% respectively. The reason why the hybrid desiccant cooling system features better performance relative to the VC system lies in the improvement brought about in the performance of the evaporator in VC unit due to desiccant dehumidification. A thermodynamic model of the hybrid desiccant system with R-22 as the refrigerant has been developed and the impact of operating parameters on the sensible heat ratio of the evaporator and the electric power saving rate has been analyzed. It is found that a majority of evaporators can operate in the dry condition even if the regeneration temperature is lower (i.e. 80 o C)

  7. PCR method for the rapid detection and discrimination of Legionella spp. based on the amplification of pcs, pmtA, and 16S rRNA genes.

    Science.gov (United States)

    Janczarek, Monika; Palusińska-Szysz, Marta

    2016-05-01

    Legionella bacteria are organisms of public health interest due to their ability to cause pneumonia (Legionnaires' disease) in susceptible humans and their ubiquitous presence in water supply systems. Rapid diagnosis of Legionnaires' disease allows the use of therapy specific for the disease. L. pneumophila serogroup 1 is the most common cause of infection acquired in community and hospital environments. The non-L. pneumophila infections are likely under-detected because of a lack of effective diagnosis. In this work, simplex and duplex PCR assays with the use of new molecular markers pcs and pmtA involved in phosphatidylcholine synthesis were specified for rapid and cost-efficient identification and distinguishing Legionella species. The sets of primers developed were found to be sensitive and specific for reliable detection of Legionella belonging to the eight most clinically relevant species. Among these, four primer sets I, II, VI, and VII used for duplex-PCRs proved to have the highest identification power and reliability in the detection of the bacteria. Application of this PCR-based method should improve detection of Legionella spp. in both clinical and environmental settings and facilitate molecular typing of these organisms.

  8. Towards the conceptual design of the ITER real-time plasma control system

    International Nuclear Information System (INIS)

    Winter, A.; Makijarvi, P.; Simrock, S.; Snipes, J.A.; Wallander, A.; Zabeo, L.

    2014-01-01

    Highlights: • We describe the main control areas and interfaces for the ITER real-time plasma control system and the current state of their design. • An overview is given for the implementation strategy for the plasma control system as part of the ITER control, data access and communication system. • Current efforts on the creation of simulation and development tools are presented. - Abstract: ITER will be the world's largest magnetic confinement tokamak fusion device and is currently under construction in southern France. The ITER Plasma Control System (PCS) is a fundamental component of the ITER Control, Data Access and Communication system (CODAC). It will control the evolution of all plasma parameters that are necessary to operate ITER throughout all phases of the discharge. The design and implementation of the PCS poses a number of unique challenges. The timescales of phenomena to be controlled spans three orders of magnitude, ranging from a few milliseconds to seconds. Novel control schemes, which have not been implemented at present-day machines need to be developed, and control schemes that are only done as demonstration experiments today will have to become routine. In addition, advances in computing technology and available physics models make the implementation of real-time or faster-than-real-time predictive calculations to forecast and subsequently to avoid disruptions or undesired plasma regimes feasible. This requires the PCS design to be adaptable in real-time to the results of these forecasting algorithms. A further novel feature is a sophisticated event handling system, which provides a means to deal with plasma related events (such as MHD instabilities or L-H transitions) or component failure. Finally, the schedule for design and implementation poses another challenge. The beginning of ITER operation will be in late 2020, but the conceptual design activity of the PCS has already commenced as required by the on-going development of

  9. The optimum operating conditions of the phased double-rotor facility at the et-R R-1 reactor. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Naguib, K; Habib, N; Kilany, M; Adib, M [Reactor and Neutron Physics Department, Nuclear Research Center, AEA., Cairo (Egypt); Wahba, M [Dept. of Engineering Physics and Mathematics, Faculty of Engineering, Ain Shams University, Cairo (Egypt)

    1996-03-01

    The pulsed neutron polyenergetic thermal beam at ET-R R-1 is produced by a phased double-rotor facility. One of the rotors has two diametrically opposite curved slots, while the second is designed to operate as a rotating collimator, the dimensions of the phased rotating collimator are selected to match the curved slot rotor. The calculated collimator transmissions at different operating conditions are found to be in good agreement with the experimental ones. The optimum operating conditions of double-rotor facility are deduced. The calculations were carried out using a computer programme RCOL. The RCOL was designed in Fortran-77 to operate on PCs. 6 figs.

  10. The optimum operating conditions of the phased double-rotor facility at the et-R R-1 reactor. Vol. 2

    International Nuclear Information System (INIS)

    Naguib, K.; Habib, N.; Kilany, M.; Adib, M.; Wahba, M.

    1996-01-01

    The pulsed neutron polyenergetic thermal beam at ET-R R-1 is produced by a phased double-rotor facility. One of the rotors has two diametrically opposite curved slots, while the second is designed to operate as a rotating collimator, the dimensions of the phased rotating collimator are selected to match the curved slot rotor. The calculated collimator transmissions at different operating conditions are found to be in good agreement with the experimental ones. The optimum operating conditions of double-rotor facility are deduced. The calculations were carried out using a computer programme RCOL. The RCOL was designed in Fortran-77 to operate on PCs. 6 figs

  11. Principal Component Analysis Coupled with Artificial Neural Networks—A Combined Technique Classifying Small Molecular Structures Using a Concatenated Spectral Database

    Directory of Open Access Journals (Sweden)

    Mihail Lucian Birsa

    2011-10-01

    Full Text Available In this paper we present several expert systems that predict the class identity of the modeled compounds, based on a preprocessed spectral database. The expert systems were built using Artificial Neural Networks (ANN and are designed to predict if an unknown compound has the toxicological activity of amphetamines (stimulant and hallucinogen, or whether it is a nonamphetamine. In attempts to circumvent the laws controlling drugs of abuse, new chemical structures are very frequently introduced on the black market. They are obtained by slightly modifying the controlled molecular structures by adding or changing substituents at various positions on the banned molecules. As a result, no substance similar to those forming a prohibited class may be used nowadays, even if it has not been specifically listed. Therefore, reliable, fast and accessible systems capable of modeling and then identifying similarities at molecular level, are highly needed for epidemiological, clinical, and forensic purposes. In order to obtain the expert systems, we have preprocessed a concatenated spectral database, representing the GC-FTIR (gas chromatography-Fourier transform infrared spectrometry and GC-MS (gas chromatography-mass spectrometry spectra of 103 forensic compounds. The database was used as input for a Principal Component Analysis (PCA. The scores of the forensic compounds on the main principal components (PCs were then used as inputs for the ANN systems. We have built eight PC-ANN systems (principal component analysis coupled with artificial neural network with a different number of input variables: 15 PCs, 16 PCs, 17 PCs, 18 PCs, 19 PCs, 20 PCs, 21 PCs and 22 PCs. The best expert system was found to be the ANN network built with 18 PCs, which accounts for an explained variance of 77%. This expert system has the best sensitivity (a rate of classification C = 100% and a rate of true positives TP = 100%, as well as a good selectivity (a rate of true negatives TN

  12. Air-conditioning and ventilation systems and components of nuclear facilities

    International Nuclear Information System (INIS)

    2006-01-01

    The Guide defines the requirements for the design, implementation and operation of the air-conditioning and ventilation systems of nuclear facilities belonging to safety classes 3 and 4, and for the related documents to be submitted to STUK (Radiation and Nuclear Safety Authority, Finland). Furthermore, the Guide describes the inspections of air-conditioning and ventilation systems to be conducted by STUK during construction and operation of the facilities. As far as systems and components belonging to safety class 2 are concerned, STUK sets additional requirements case by case. In general, air-conditioning systems refer to systems designed to manage the indoor air cleanness, temperature, humidity and movement. In some rooms of a nuclear power plant, ventilation systems are also used to prevent radioactive materials from spreading outside the rooms. Guide YVL1.0 defines the safety principles concerning the air-conditioning and ventilation of nuclear power plants. Guide YVL2.0 gives the requirements for the design of nuclear power plant systems. In addition, YVLGuide groups 3, 4, 5 and 7 deal with the requirements for air-conditioning and ventilation systems with regard to the mechanical equipment, fire prevention, electrical systems, instrumentation and control technology, and the restriction of releases. The rules and regulations issued by the Ministry of the Environment and the Ministry of the Interior (RakMK, the Finnish building code) concerning the design and operation of air-conditioning and ventilation systems and the related fire protection design bases also apply to nuclear facilities. Exhaust gas treatment systems, condenser vacuum systems of boiling water reactor plants and leak collection systems are excluded from the scope of this Guide

  13. Robustness analysis of pull strategies in multi-product systems

    Directory of Open Access Journals (Sweden)

    Chukwunonyelum Emmanuel Onyeocha

    2015-09-01

    Full Text Available Purpose: This paper examines the behaviour of shared and dedicated Kanban allocation policies of Hybrid Kanban-CONWIP and Basestock-Kanban-CONWIP control strategies in multi-product systems; with considerations to robustness of optimal solutions to environmental and system variabilities. Design/methodology/approach: Discrete event simulation and evolutionary multi-objective optimisation approach were utilised to develop Pareto-frontier or sets of non-dominated optimal solutions and for selection of an appropriate decision set for the control parameters in the shared Kanban allocation policy (S-KAP and dedicated Kanban allocation policy (D-KAP. Simulation experiments were carried out via ExtendSim simulation application software. The outcomes of PCS+KAP performances were compared via all pairwise comparison and Nelson’s screening and selection procedure for superior PCS+KAP under negligible environmental and system stability. To determine superior PCS+KAP under systems’ and environmental variability, the optimal solutions were tested for robustness using Latin hypercube sampling technique and stochastic dominance test. Findings: The outcome of this study shows that under uncontrollable environmental variability, dedicated Kanban allocation policy outperformed shared Kanban allocation policy in serial manufacturing system with negligible and in complex assembly line with setup times. Moreover, the BK-CONWIP is shown as superior strategy to HK-CONWIP. Research limitations/implications: Future research should be conducted to verify the level of flexibility of BK-CONWIP with respect to product mix and product demand volume variations in a complex multi-product system Practical implications: The outcomes of this work are applicable to multi-product manufacturing industries with significant setup times and systems with negligible setup times. The multi-objective optimisation provides decision support for selection of control-parameters such that

  14. Periodic solutions of asymptotically linear Hamiltonian systems without twist conditions

    Energy Technology Data Exchange (ETDEWEB)

    Cheng Rong [Coll. of Mathematics and Physics, Nanjing Univ. of Information Science and Tech., Nanjing (China); Dept. of Mathematics, Southeast Univ., Nanjing (China); Zhang Dongfeng [Dept. of Mathematics, Southeast Univ., Nanjing (China)

    2010-05-15

    In dynamical system theory, especially in many fields of applications from mechanics, Hamiltonian systems play an important role, since many related equations in mechanics can be written in an Hamiltonian form. In this paper, we study the existence of periodic solutions for a class of Hamiltonian systems. By applying the Galerkin approximation method together with a result of critical point theory, we establish the existence of periodic solutions of asymptotically linear Hamiltonian systems without twist conditions. Twist conditions play crucial roles in the study of periodic solutions for asymptotically linear Hamiltonian systems. The lack of twist conditions brings some difficulty to the study. To the authors' knowledge, very little is known about the case, where twist conditions do not hold. (orig.)

  15. Signal conditioning circuitry design for instrumentation systems.

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Cory A.

    2012-01-01

    This report details the current progress in the design, implementation, and validation of the signal conditioning circuitry used in a measurement instrumentation system. The purpose of this text is to document the current progress of a particular design in signal conditioning circuitry in an instrumentation system. The input of the signal conditioning circuitry comes from a piezoresistive transducer and the output will be fed to a 250 ksps, 12-bit analog-to-digital converter (ADC) with an input range of 0-5 V. It is assumed that the maximum differential voltage amplitude input from the sensor is 20 mV with an unknown, but presumably high, sensor bandwidth. This text focuses on a specific design; however, the theory is presented in such a way that this text can be used as a basis for future designs.

  16. ADVANCED TOKAMAK OPERATION USING THE DIII-D PLASMA CONTROL SYSTEM

    International Nuclear Information System (INIS)

    HUMPHREYS, DA; FERRON, JR; GAROFALO, AM; HYATT, AW; JERNIGAN, TC; JOHNSON, RD; LAHAYE, RJ; LEUER, JA; OKABAYASHI, M; PENAFLOR, BG; SCOVILLE, JT; STRAIT, EJ; WALKER, ML; WHYTE, DG

    2002-01-01

    A271 ADVANCED TOKAMAK OPERATION USING THE DIII-D PLASMA CONTROL SYSTEM. The principal focus of experimental operations in the DIII-D tokamak is the advanced tokamak (AT) regime to achieve, which requires highly integrated and flexible plasma control. In a high performance advanced tokamak, accurate regulation of the plasma boundary, internal profiles, pumping, fueling, and heating must be well coordinated with MHD control action to stabilize such instabilities as tearing modes and resistive wall modes. Sophisticated monitors of the operational regime must provide detection of off-normal conditions and trigger appropriate safety responses with acceptable levels of reliability. Many of these capabilities are presently implemented in the DIII-D plasma control system (PCS), and are now in frequent or routine operational use. The present work describes recent development, implementation, and operational experience with AT regime control elements for equilibrium control, MHD suppression, and off-normal event detection and response

  17. ACTIVE FILTER HARDWARE DESIGN and PERFORMANCE FOR THE DIII-D PLASMA CONTROL SYSTEM

    International Nuclear Information System (INIS)

    SELLERS, D.; FERRON, J.R; WALKER, M.L; BROESCH, J.D

    2004-03-01

    OAK-B135 The digital plasma control system (PCS), currently in operation on the DIII-D tokamak, requires inputs from a large number of sensors. Due to the nature of the digitizers and the relative noisy environment from which these signals are derived, each of the 32 signals must be conditioned via an active filter. Two different types of filters, Chebyshev and Bessel with fixed frequencies: 100 Hz Bessel was used for filtering the motional Stark effect diagnostic data. 800 Hz Bessel was designed to filter plasma control data and 1200 Hz Chebyshev is used with closed loop control of choppers. The performance of the plasma control system is greatly influenced by how well the actual filter responses match the software model used in the control system algorithms. This paper addresses the various issues facing the designer in matching the electrical design with the theoretical

  18. Research and Development of Rapid Design Systems for Aerospace Structure

    Science.gov (United States)

    Schaeffer, Harry G.

    1999-01-01

    This report describes the results of research activities associated with the development of rapid design systems for aerospace structures in support of the Intelligent Synthesis Environment (ISE). The specific subsystems investigated were the interface between model assembly and analysis; and, the high performance NASA GPS equation solver software system in the Windows NT environment on low cost high-performance PCs.

  19. 42 CFR 493.1240 - Condition: Preanalytic systems.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Preanalytic systems. 493.1240 Section 493.1240 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... of the preanalytic systems and correct identified problems as specified in § 493.1249 for each...

  20. An Automatic Control System for Conditioning 30 GHz Accelerating Structures

    CERN Document Server

    Dubrovskiy, A

    2008-01-01

    A software application programme has been developed to allow fast and automatic high-gradient conditioning of accelerating structures at 30 GHz in CTF3. The specificity of the application is the ability to control the high-power electron beam which produces the 30 GHz RF power used to condition the accelerating structures. The programme permits operation round the clock with minimum manpower requirements. In this paper the fast control system, machine control system, logging system, graphical user control interface and logging data visualization are described. An outline of the conditioning control system itself and of the feedback controlling peak power and pulse length is given. The software allows different types of conditioning strategies to be programmed

  1. High average power solid state laser power conditioning system

    International Nuclear Information System (INIS)

    Steinkraus, R.F.

    1987-01-01

    The power conditioning system for the High Average Power Laser program at Lawrence Livermore National Laboratory (LLNL) is described. The system has been operational for two years. It is high voltage, high power, fault protected, and solid state. The power conditioning system drives flashlamps that pump solid state lasers. Flashlamps are driven by silicon control rectifier (SCR) switched, resonant charged, (LC) discharge pulse forming networks (PFNs). The system uses fiber optics for control and diagnostics. Energy and thermal diagnostics are monitored by computers

  2. Muscular condition monitoring system using fiber bragg grating sensors

    International Nuclear Information System (INIS)

    Kim, Heon Young; Lee, Jin Hyuk; Kim, Dae Hyun

    2014-01-01

    Fiber optic sensors (FOS) have advantages such as electromagnetic interference (EMI) immunity, corrosion resistance and multiplexing capability. For these reasons, they are widely used in various condition monitoring systems (CMS). This study investigated a muscular condition monitoring system using fiber optic sensors (FOS). Generally, sensors for monitoring the condition of the human body are based on electro-magnetic devices. However, such an electrical system has several weaknesses, including the potential for electro-magnetic interference and distortion. Fiber Bragg grating (FBG) sensors overcome these weaknesses, along with simplifying the devices and increasing user convenience. To measure the level of muscle contraction and relaxation, which indicates the muscle condition, a belt-shaped FBG sensor module that makes it possible to monitor the movement of muscles in the radial and circumferential directions was fabricated in this study. In addition, a uniaxial tensile test was carried out in order to evaluate the applicability of this FBG sensor module. Based on the experimental results, a relationship was observed between the tensile stress and Bragg wavelength of the FBG sensors, which revealed the possibility of fabricating a muscular condition monitoring system based on FBG sensors.

  3. Muscular condition monitoring system using fiber bragg grating sensors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heon Young; Lee, Jin Hyuk; Kim, Dae Hyun [Seoul National University of Technology, Seoul (Korea, Republic of)

    2014-10-15

    Fiber optic sensors (FOS) have advantages such as electromagnetic interference (EMI) immunity, corrosion resistance and multiplexing capability. For these reasons, they are widely used in various condition monitoring systems (CMS). This study investigated a muscular condition monitoring system using fiber optic sensors (FOS). Generally, sensors for monitoring the condition of the human body are based on electro-magnetic devices. However, such an electrical system has several weaknesses, including the potential for electro-magnetic interference and distortion. Fiber Bragg grating (FBG) sensors overcome these weaknesses, along with simplifying the devices and increasing user convenience. To measure the level of muscle contraction and relaxation, which indicates the muscle condition, a belt-shaped FBG sensor module that makes it possible to monitor the movement of muscles in the radial and circumferential directions was fabricated in this study. In addition, a uniaxial tensile test was carried out in order to evaluate the applicability of this FBG sensor module. Based on the experimental results, a relationship was observed between the tensile stress and Bragg wavelength of the FBG sensors, which revealed the possibility of fabricating a muscular condition monitoring system based on FBG sensors.

  4. Impact on cost accuracy and profitability from implementing product configuration system – A case-study

    DEFF Research Database (Denmark)

    Myrodia, Anna; Kristjansdottir, Katrin; Hvam, Lars

    2015-01-01

    This article aims at analyzing the impacts from implementing a product configuration system (PCS) on company profitability and improved cost estimations in the sales phase. Companies that have implemented PCSs have achieved substantial benefits in terms of being more in control of their product...... assortment, making the right decisions in the sales phase and increased sales of optimal products. Those benefits should have direct impact on improved profitability in terms of increased contribution ratios and more accurate cost estimations used to determine the price in the budgetary quotations...... and accuracy of the cost estimation in the sales phase can be achieved from implementing a PCS....

  5. Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices

    DEFF Research Database (Denmark)

    Bako-Biro, Zsolt; Wargocki, Pawel; Weschler, Charles J.

    2004-01-01

    In groups of six, 30 female subjects were exposed for 4.8 h in a low-polluting office to each of two conditions the presence or absence of 3-month-old personal computers (PCs). These PCs were placed behind a screen so that they were not visible to the subjects. Throughout the exposure the outdoor...... air supply was maintained at 10 l/s per person. Under each of the two conditions the subjects performed simulated office work using old low-polluting PCs. They also evaluated the air quality and reported Sick Building Syndrome (SBS) symptoms. The PCs were found to be strong indoor pollution sources......, even after they had been in service for 3 months. The sensory pollution load of each PC was 3.4 olf, more than three times the pollution of a standard person. The presence of PCs increased the percentage of people dissatisfied with the perceived air quality from 13 to 41% and increased by 9% the time...

  6. Small photovoltaic setup for the air conditioning system

    Directory of Open Access Journals (Sweden)

    Masiukiewicz Maciej

    2017-01-01

    Full Text Available The increasing interest in air conditioning systems for residential applications in Poland will certainly increase the demand for electricity during the summer period. Due to this fact a growing interest in solutions that help to lower the electricity consumption in this sector is observed. The problem of increased energy demand for air conditioning purposes can be solved by transfer the consumption of electricity from the grid system to renewable energy sources (RES. The greatest demand for cooling occurs during the biggest sunlight. This is the basis for the analysis of technical power system based on photovoltaic cells (PV to power the split type air conditioner. The object of the study was the commercial residential airconditioning inverter units with a capacity of 2.5kW. A network electricity production system for their own use with the possibility of buffering energy in batteries (OFF-GRID system. Currently, on the Polish market, there are no developed complete solutions dedicated to air conditioning systems based on PV. In Poland, solar energy is mainly used for heat production in solar collectors. The proposed solution will help to increase the popularity of PV systems in the Polish market as an alternative to other RES. The basic conclusion is that the amount of PV energy generated was sufficient to cover the daily energy requirement of the air conditioner.

  7. Small photovoltaic setup for the air conditioning system

    Science.gov (United States)

    Masiukiewicz, Maciej

    2017-10-01

    The increasing interest in air conditioning systems for residential applications in Poland will certainly increase the demand for electricity during the summer period. Due to this fact a growing interest in solutions that help to lower the electricity consumption in this sector is observed. The problem of increased energy demand for air conditioning purposes can be solved by transfer the consumption of electricity from the grid system to renewable energy sources (RES). The greatest demand for cooling occurs during the biggest sunlight. This is the basis for the analysis of technical power system based on photovoltaic cells (PV) to power the split type air conditioner. The object of the study was the commercial residential airconditioning inverter units with a capacity of 2.5kW. A network electricity production system for their own use with the possibility of buffering energy in batteries (OFF-GRID system). Currently, on the Polish market, there are no developed complete solutions dedicated to air conditioning systems based on PV. In Poland, solar energy is mainly used for heat production in solar collectors. The proposed solution will help to increase the popularity of PV systems in the Polish market as an alternative to other RES. The basic conclusion is that the amount of PV energy generated was sufficient to cover the daily energy requirement of the air conditioner.

  8. 42 CFR 493.1290 - Condition: Postanalytic systems.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Postanalytic systems. 493.1290 Section 493.1290 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... systems and correct identified problems as specified in § 493.1299 for each specialty and subspecialty of...

  9. 42 CFR 493.1250 - Condition: Analytic systems.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Analytic systems. 493.1250 Section 493.1250 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... quality testing. The laboratory must monitor and evaluate the overall quality of the analytic systems and...

  10. Usage Frequency of Product Configuration Systems Relative to Integrations and Fields of Application

    DEFF Research Database (Denmark)

    Shafiee, Sara; Kristjansdottir, Katrin; Hvam, Lars

    2017-01-01

    Product Configuration Systems (PCS) are automatic solutions that can support and facilitate the sales and engineering processes. PCSs have recently attracted increased attention both from the researches and practitioners. There are variety of challenges reported in the literature as consequences...

  11. Entrepreneurial actions in public management: analysis of the Programme “Crédito Solidário” (PCS in a southern town of Minas Gerais State [doi: 10.21529/RECADM.2016005

    Directory of Open Access Journals (Sweden)

    Camila Assis Silva

    2017-01-01

    Full Text Available One of the current trends in the Campo de Públicas is the inclusion of entrepreneurship subject in the discussion on the public policy formulation and implementation. This kind of thinking came from the understanding that with the globalization process it was necessary for the public sector to adapt to changes through a more flexible management that could respond to society’s demands. This research aims to analyze, from the beneficiaries’s point of view of the Programme “Programa Crédito Solidário” (PCS in a town in the southern of Minas Gerais State, in levels of economic, social and political emancipation of those who benefit from this public policy. It becomes clear how this type of action represents a process of implementation and formulation of public projects in a paradoxical condition, because at the same time it promotes new alternatives for the development of small business from the Economia Solidária (Solidarity Economy, it alters to be rather weak in a context of economical, social and political emancipation of beneficiaries.   Keywords Public entrepreneurship; Solidarity economy; Emancipation.

  12. Operational experience of air washer based ventilation system for power conditioning system of Indus-2

    International Nuclear Information System (INIS)

    Pandey, R.M.; Baghel, S.L.; Parate, J.K.; Ahlawat, Sandeep; Rawlani, B.K.; Chouksey, Sanjay

    2015-01-01

    Indus-2 Synchrotron Accelerator requires high quality conditioned uninterrupted AC mains power for their smooth and reliable operation. Three units of 1670 kVA and one unit of 1100 kVA capacity rotary uninterruptible power conditioning systems (UPS) were installed and commissioned. These UPS units require dust free and cool ambient conditions for smooth operation. In order to meet the ventilation requirements, an evaporative cooling system of 80000 cubic meter/hour capacity with filtration units was designed, installed and commissioned in February 2011 and is operational on round-the-clock basis. Evaporative cooling scheme was chosen as has various advantages over a refrigerated system like lower initial capital costs, lower energy usage, lower running costs, less greenhouse gas and it does not contribute to ozone depletion. The ventilation system filters the environment air in stages up to 5 micron level and being conditioned with an automatic controlled soft water circulating system with cooling pads. An instrumentation and control scheme is included in the system to provide the automation requirements for operating 24 x 7 through the year. All the mechanical, hydraulic and electrical devices are maintained by providing preventive maintenance work without affecting the accelerator machine operation. Availability and reliability of the system was analysed based on the failure data. In Year 2014, the ventilation system was upgraded to accommodate standby blower unit, coupling unit and improved quality of supply air with new air conditioning devices. The control panel monitors the condition of air in the UPS hall and maintainsup to 28°C air temperature and 85% maximum relative humidity in round-the clock shift with more than 98% operational reliability. In this paper, we present design philosophy, installation, instrumentation, testing, operation experience and availability of the ventilation system for Power Conditioning System, Indus complex. (author)

  13. LHCb Conditions database operation assistance systems

    International Nuclear Information System (INIS)

    Clemencic, M; Shapoval, I; Cattaneo, M; Degaudenzi, H; Santinelli, R

    2012-01-01

    The Conditions Database (CondDB) of the LHCb experiment provides versioned, time dependent geometry and conditions data for all LHCb data processing applications (simulation, high level trigger (HLT), reconstruction, analysis) in a heterogeneous computing environment ranging from user laptops to the HLT farm and the Grid. These different use cases impose front-end support for multiple database technologies (Oracle and SQLite are used). Sophisticated distribution tools are required to ensure timely and robust delivery of updates to all environments. The content of the database has to be managed to ensure that updates are internally consistent and externally compatible with multiple versions of the physics application software. In this paper we describe three systems that we have developed to address these issues. The first system is a CondDB state tracking extension to the Oracle 3D Streams replication technology, to trap cases when the CondDB replication was corrupted. Second, an automated distribution system for the SQLite-based CondDB, providing also smart backup and checkout mechanisms for the CondDB managers and LHCb users respectively. And, finally, a system to verify and monitor the internal (CondDB self-consistency) and external (LHCb physics software vs. CondDB) compatibility. The former two systems are used in production in the LHCb experiment and have achieved the desired goal of higher flexibility and robustness for the management and operation of the CondDB. The latter one has been fully designed and is passing currently to the implementation stage.

  14. Methodology for quantitative assessment of technical condition in industrial systems

    Energy Technology Data Exchange (ETDEWEB)

    Steinbach, C [Marintek AS (Norway); Soerli, A [Statoil (Norway)

    1999-12-31

    As part of the Eureka project Ageing Management a methodology has been developed to assess the technical condition of industrial systems. The first part of the presentation argues for the use of technical condition parameters in the context of maintenance strategies. Thereafter the term `technical condition` is defined more thoroughly as it is used within the project. It is claimed that the technical condition of a system - such as a feed water system of a nuclear power plant, or a water injection system on an oil platform - may be determined by aggregating the condition of its smaller components using a hierarchic approach. The hierarchy has to be defined in co-operation with experienced personnel and reflects the impact of degradation of elements on a lower level to nodes higher in the hierarchy. The impact is divided into five categories with respect to safety, environment, availability, costs and man-hours. To determine the technical condition of the bottom elements of the hierarchy, available data is used from both an on-line condition monitoring system and maintenance history. The second part of the presentation introduces the prototype software tool TeCoMan which utilises the theory and applies it to installations of the participating companies. First results and gained experiences with the method and tool are discussed. (orig.)

  15. Methodology for quantitative assessment of technical condition in industrial systems

    Energy Technology Data Exchange (ETDEWEB)

    Steinbach, C. [Marintek AS (Norway); Soerli, A. [Statoil (Norway)

    1998-12-31

    As part of the Eureka project Ageing Management a methodology has been developed to assess the technical condition of industrial systems. The first part of the presentation argues for the use of technical condition parameters in the context of maintenance strategies. Thereafter the term `technical condition` is defined more thoroughly as it is used within the project. It is claimed that the technical condition of a system - such as a feed water system of a nuclear power plant, or a water injection system on an oil platform - may be determined by aggregating the condition of its smaller components using a hierarchic approach. The hierarchy has to be defined in co-operation with experienced personnel and reflects the impact of degradation of elements on a lower level to nodes higher in the hierarchy. The impact is divided into five categories with respect to safety, environment, availability, costs and man-hours. To determine the technical condition of the bottom elements of the hierarchy, available data is used from both an on-line condition monitoring system and maintenance history. The second part of the presentation introduces the prototype software tool TeCoMan which utilises the theory and applies it to installations of the participating companies. First results and gained experiences with the method and tool are discussed. (orig.)

  16. Recent results on cleaning and conditioning the ATF vacuum system

    International Nuclear Information System (INIS)

    Langley, R.A.; Clark, T.L.; Glowienka, J.C.; Goulding, R.H.; Mioduszewski, P.K.; Rasmussen, D.A.; Rayburn, T.F.; Schaich, C.R.; Shepard, T.D.; Simpkins, J.E.; Yarber, J.L.

    1990-01-01

    Techniques for cleaning and conditioning the vacuum vessel of the Advanced Toroidal Facility (ATF) and its internal components are described. The vacuum vessel cleaning technique combines baking to 150 degree C and glow discharges with hydrogen gas. Chromium gettering is used to further condition the system. The major internal components are the anodized aluminum baffles in the Thomson scattering system, a graphite-shielded ICRF antenna, two graphite limiters, and a diagnostic graphite plate. Three independent heating systems are used to bake some of the major components of the system. The major characteristics used for assessing cleanliness and conditioning progress are the maximum pressure attained during bakeout, the results of gas analysis, and revelant plasma parameters (e.g., time to radiative decay). Details of the various cleaning and conditioning procedures and results are presented

  17. Operational characteristic analysis of PV generation system for grid connection by using a senseless MPPT control

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.-J.; Kim, K.-H.; Park, H.-Y.; Seo, H.-R.; Park, M.; Yu, I.-K. [Changwon National Univ., SarimDong (Korea, Republic of). Dept. of Electrical Engineering

    2007-07-01

    In photovoltaics, the sun's light energy is captured to create electricity. One of the key issues about a photovoltaic (PV) generation system is to keep the output power of photovoltaic cells maximized under any weather conditions. In a conventional maximum power point tracking (MPPT) control method, both voltage and current coming out from PV array require feedback. The system may fail to track the MPP of a PV array when unexpected weather conditions happen. This paper proposed a novel PV output senseless (POS) control method to solve the problem. The proposed POS MPPT control method only had one factor to consider, the load current. To verify this theory, a POS MPPT control was applied to a manufactured PV generation system, and the results of the the simulated and experimental data under real weather conditions were compared and analyzed. Several tables and diagrams were presented, including the circuit diagram of a manufactured PV generation system connected to grid as well as the the specifications of the PV array and PCS used for the experiment. Reasonable results were obtained in this study. In addition, the scheme was found to be very useful in maximizing power from PV array to load with feedback of only the load current. 8 refs., 3 tabs., 15 figs.

  18. Development of condition monitoring and diagnosis system for standby diesel generator

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kwang Hee; Park, Jong Hyuck; Park, Jong Eun [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The emergency diesel generator (EDG) of the nuclear power plant is designed to supply the power to the nuclear on Station Black Out (SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a condition monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developed the online condition monitoring and diagnosis system for the wolsong unit 3 and 4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring and diagnosis system (SDG MDS) for the wolsong standby diesel generator are described. By using the condition monitoring module of the SDG MDS, performance monitoring function for major operating parameters of EDG reliability program required by Reg. guide 1.155 can be operated as on line monitoring system.

  19. Development of condition monitoring and diagnosis system for standby diesel generator

    International Nuclear Information System (INIS)

    Choi, Kwang Hee; Park, Jong Hyuck; Park, Jong Eun

    2009-01-01

    The emergency diesel generator (EDG) of the nuclear power plant is designed to supply the power to the nuclear on Station Black Out (SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a condition monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developed the online condition monitoring and diagnosis system for the wolsong unit 3 and 4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring and diagnosis system (SDG MDS) for the wolsong standby diesel generator are described. By using the condition monitoring module of the SDG MDS, performance monitoring function for major operating parameters of EDG reliability program required by Reg. guide 1.155 can be operated as on line monitoring system

  20. The application of gas ejector for road transport air conditioning system

    Science.gov (United States)

    Sumeru, Nasution, Henry; Ani, Farid Nasir

    2012-06-01

    The depletion of fossil fuel supply requires fuel and energy saving in energy utilization system. Therefore, these required the development of new and efficient technologies as to reduce fuel consumption especially in air conditioning of road vehicles. Currently, the air conditioning for road vehicles uses vapor compression system. Although the vapor compression system has high COP, the compressor is driven by vehicle engines, which take additional fuel consumption when the air conditioning system is in operation. In this study, the waste heat of radiator drives the ejector refrigeration for air conditioning. Although the ejector refrigeration system has low COP, the use of heat driven air conditioning will reduce the fuel consumption as compared with conventional system. This is because the systems do not use the mechanical engine load. The analysis of this study is based on the ejector refrigeration system using natural refrigerant (isobutene). The evaporation temperature is 10°C, condensation temperature is 35°C, generator temperature is 90°C with ejector isentropic efficiency of 0.7, and the COP system is 0.25. The heat released by the radiator of typical small road vehicles is between 60 to 100 kW and if the generator absorbs 20% of the heat, the heat contained in the generator is 12 to 20 kW. When the ejector air conditioning system has a COP 0.25, it will generate cooling capacity between 3 to 5 kW, compared with the conventional air conditioning of similar vehicles, which is approximately 2 to 4.4 kW.

  1. Thermal energy recovery of air conditioning system--heat recovery system calculation and phase change materials development

    International Nuclear Information System (INIS)

    Gu Zhaolin; Liu Hongjuan; Li Yun

    2004-01-01

    Latent heat thermal energy storage systems can be used to recover the rejected heat from air conditioning systems, which can be used to generate low-temperature hot water. It decreases not only the consumption of primary energy for heating domestic hot water but also the calefaction to the surroundings due to the rejection of heat from air conditioning systems. A recovery system using phase change materials (PCMs) to store the rejected (sensible and condensation) heat from air conditioning system has been developed and studied, making up the shortage of other sensible heat storage system. Also, PCMs compliant for heat recovery of air conditioning system should be developed. Technical grade paraffin wax has been discussed in this paper in order to develop a paraffin wax based PCM for the recovery of rejected heat from air conditioning systems. The thermal properties of technical grade paraffin wax and the mixtures of paraffin wax with lauric acid and with liquid paraffin (paraffin oil) are investigated and discussed, including volume expansion during the phase change process, the freezing point and the heat of fusion

  2. Development of control and data processing system for JAERI ERL-FEL

    International Nuclear Information System (INIS)

    Kikuzawa, Nobuhiro

    2005-03-01

    A personal computer (PC) based distributed control system has been developed for Free Electron Laser (FEL) at Japan Atomic Energy Research Institute (JAERI) and operated since 1992. The control system was implemented on Ethernet LAN of PCs, Nippon Electric Company (NEC Corp.) PC-9800 series 32 bit personal computers. It became troublesome to maintain the control system, because many application programs did not work on outdated hardware interfaces and operating system. Furthermore, since security updates of the operating system (OS) were no longer provided, the problem was in network security when many PCs were connected with the LAN. We have to solve these problems and to improve the reliability and the safety of the control system, an ITRON-based controller was developed. In Japan, the ITRON is very popular and embedded in many products such as industrial instruments or household appliances that are demanded of its high reliability. When the local controller was installed, a new control program was developed by Java language which had high compatibility on many platforms so that replacement of the computer for consoles might become easy in future. High reliability and interchangeability have been successfully realized by them, and the control system made long continuous operation possible. (author)

  3. Wire system aging assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Fantoni, P.F.

    2007-04-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains some test results of a method for wire system condition monitoring, developed at the Halden Reactor Project, called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. (au)

  4. Thermodynamic analysis of the two-phase ejector air-conditioning system for buses

    International Nuclear Information System (INIS)

    Ünal, Şaban; Yilmaz, Tuncay

    2015-01-01

    Air-conditioning compressors of the buses are usually operated with the power taken from the engine of the buses. Therefore, an improvement in the air-conditioning system will reduce the fuel consumption of the buses. The improvement in the coefficient of performance (COP) of the air-conditioning system can be provided by using the two-phase ejector as an expansion valve in the air-conditioning system. In this study, the thermodynamic analysis of bus air-conditioning system enhanced with a two-phase ejector and two evaporators is performed. Thermodynamic analysis is made assuming that the mixing process in ejector occurs at constant cross-sectional area and constant pressure. The increase rate in the COP with respect to conventional system is analyzed in terms of the subcooling, condenser and evaporator temperatures. The analysis shows that COP improvement of the system by using the two phase ejector as an expansion device is 15% depending on design parameters of the existing bus air-conditioning system. - Highlights: • Thermodynamic analysis of the two-phase ejector refrigeration system. • Analysis of the COP increase rate of bus air-conditioning system. • Analysis of the entrainment ratio of the two-phase ejector refrigeration system

  5. A prototype nuclear emergency response decision making expert system

    International Nuclear Information System (INIS)

    Chang, C.; Shih, C.; Hong, M.; Yu, W.; Su, M.; Wang, S.

    1990-01-01

    A prototype of emergency response expert system developed for nuclear power plants, has been fulfilled by Institute of Nuclear Energy Research. Key elements that have been implemented for emergency response include radioactive material dispersion assessment, dynamic transportation evacuation assessment, and meteorological parametric forecasting. A network system consists of five 80386 Personal Computers (PCs) has been installed to perform the system functions above. A further project is still continuing to achieve a more complicated and fanciful computer aid integral emergency response expert system

  6. Linearizability conditions for Lotka-Volterra planar complex cubic systems

    International Nuclear Information System (INIS)

    Gine, Jaume; Romanovski, Valery G

    2009-01-01

    In this paper, we investigate the linearizability problem for the two-dimensional planar complex system x-dot=x(1-a 10 x-a 01 y-a 20 x 2 -a 11 xy-a 02 y 2 ), y-dot=(1-b 10 x-b 01 y-b 20 x 2 -b 11 xy-b 02 y 2 ). The necessary and sufficient conditions for the linearizability of this system are found. From them the conditions for isochronicity of the corresponding real system can be derived

  7. Dynamic simulation of variable capacity refrigeration systems under abnormal conditions

    International Nuclear Information System (INIS)

    Liang Nan; Shao Shuangquan; Tian Changqing; Yan Yuying

    2010-01-01

    There are often abnormal working conditions at evaporator outlet of a refrigeration system, such as two-phase state in transient process, and it is essential to investigate such transient behaviours for system design and control strategy. In this paper, a dynamic lumped parameter model is developed to simulate the transient behaviours of refrigeration system with variable capacity in both normal and abnormal working conditions. The appropriate discriminant method is adopted to switch the normal and abnormal conditions smoothly and to eliminate the simulated data oscillation. In order to verify the dynamic model, we built a test system with variable frequency compressor, water-cooling condenser, evaporator and electronic expansion valve. Calculated values from the mathematical model show reasonable agreement with the experimental data. The simulation results show that the transient behaviours of the variable capacity refrigeration system in the abnormal working conditions can be calculated reliably with the dynamic model when the compressor rotary speed or the opening of electronic expansion valve changes abruptly.

  8. Remaining useful life estimation for deteriorating systems with time-varying operational conditions and condition-specific failure zones

    Directory of Open Access Journals (Sweden)

    Li Qi

    2016-06-01

    Full Text Available Dynamic time-varying operational conditions pose great challenge to the estimation of system remaining useful life (RUL for the deteriorating systems. This paper presents a method based on probabilistic and stochastic approaches to estimate system RUL for periodically monitored degradation processes with dynamic time-varying operational conditions and condition-specific failure zones. The method assumes that the degradation rate is influenced by specific operational condition and moreover, the transition between different operational conditions plays the most important role in affecting the degradation process. These operational conditions are assumed to evolve as a discrete-time Markov chain (DTMC. The failure thresholds are also determined by specific operational conditions and described as different failure zones. The 2008 PHM Conference Challenge Data is utilized to illustrate our method, which contains mass sensory signals related to the degradation process of a commercial turbofan engine. The RUL estimation method using the sensor measurements of a single sensor was first developed, and then multiple vital sensors were selected through a particular optimization procedure in order to increase the prediction accuracy. The effectiveness and advantages of the proposed method are presented in a comparison with existing methods for the same dataset.

  9. Accelerator optimization using a network control and acquisition system

    International Nuclear Information System (INIS)

    Geddes, Cameron G.R.; Catravas, P.E.; Faure, Jerome; Toth, Csaba; Tilborg, J. van; Leemans, Wim P.

    2002-01-01

    Accelerator optimization requires detailed study of many parameters, indicating the need for remote control and automated data acquisition systems. A control and data acquisition system based on a network of commodity PCs and applications with standards based inter-application communication is being built for the l'OASIS accelerator facility. This system allows synchronous acquisition of data at high (> 1 Hz) rates and remote control of the accelerator at low cost, allowing detailed study of the acceleration process

  10. Recent results on cleaning and conditioning the ATF vacuum system

    International Nuclear Information System (INIS)

    Langley, R.A.; Clark, T.L.; Glowienka, J.C.

    1989-01-01

    Techniques for cleaning and conditioning the vacuum vessel of the Advanced Toroidal Facility (ATF) and its internal components are described. The vacuum vessel cleaning technique combines baking to 150/degree/C and glow discharges with hydrogen gas. Chromium gettering is used to further condition the system. The major internal components are the anodized aluminum baffles in the Thomson scattering system, a graphite-shielded ICRF antenna, two graphite limiters, and a diagnostic graphite plate. Three independent heating systems are used to bake some of the major components of the system. The major characteristics used for assessing cleanliness and conditioning progress are the maximum pressure attained during bakeout, the results of gas analysis, and relevant plasma parameters (e.g., time to radiative decay). Details of the various cleaning and conditioning procedures and results are presented. 5 refs., 8 figs., 3 tabs

  11. Onboard power line conditioning system for an electric or hybrid vehicle

    Science.gov (United States)

    Kajouke, Lateef A.; Perisic, Milun

    2016-06-14

    A power line quality conditioning system for a vehicle includes an onboard rechargeable direct current (DC) energy storage system and an onboard electrical system coupled to the energy storage system. The energy storage system provides DC energy to drive an electric traction motor of the vehicle. The electrical system operates in a charging mode such that alternating current (AC) energy from a power grid external to the vehicle is converted to DC energy to charge the DC energy storage system. The electrical system also operates in a vehicle-to-grid power conditioning mode such that DC energy from the DC energy storage system is converted to AC energy to condition an AC voltage of the power grid.

  12. Quality assurance of radiotherapy and its clinical assessment

    International Nuclear Information System (INIS)

    Inoue, Toshihiko

    2002-01-01

    We investigated the clinical quality assurance (QA) of radiotherapy in Japan since 1981. The aim of this study was to establish the QA of a radiotherapy system and its clinical assessment in Japan. We introduced the Patterns of Care Study (PCS) into Japan to perform this study in 1996. The PCS is a retrospective study designed to establish the national practice for cancer patients during a specific period and should be a complementary study to a prospective randomized controlled study. We collected precise data for 4399 patients with carcinomas of the breast, cervix, esophagus, lung and prostate by means of external audits for 96 institutes from 1998 through 2001. Patients were randomly sampled with two-stage cluster sampling. We stratified 556 institutes into four categories according to the academic condition and annual number of radiotherapy patients. National and regional averages of various factors of radiotherapy could be calculated and were used to measure QA of radiotherapy. Using a standard score, we could compare the process of individual institutions with national averages and feed back the evaluation score to each institution. With a PCS process survey, we could observe the dissemination of the treatment method under evidence-based medicine from the prospective randomized controlled study. We proposed future prediction of the number of radiotherapy patients and a counter plan for equipment and personnel. The first US-Japan PCS Workshop was held at San Francisco in 2001. We could establish QA of a radiotherapy system using PCS 1995-97 in Japan. (author)

  13. The effects of system configuration and operating condition on the MCFC system efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Kang, B.S. [Korea Electric Power Research Institute, Taejeon (Korea)

    2001-07-01

    The process simulation model of an externally reformed molten carbonate fuel cell (MCFC) system is used to analyze quantitatively the parametric effect on the system efficiency. In order to verify the MCFC process simulation model, the 25-kW system was analyzed on the basis of the experimental data and its calculated efficiency showed reasonable. The overall system efficiency of high-temperature fuel cell system, especially MCFC, can not be increased without the proper thermal integration between heat recovery units and additional power generation from auxiliary power generating units such as turbines. The simulation results show that the configuration of unit operators in a given system has great effect on the system efficiency while the system size and operating condition have slightly lower effect on it. Based on the system configuration, optimal operating condition including fuel, oxidant utilization, and recycle ratio can be specified to maximize the system efficiency. (author). 12 refs., 10 figs., 2 tabs.

  14. Thermal Environment for Classrooms. Central System Approach to Air Conditioning.

    Science.gov (United States)

    Triechler, Walter W.

    This speech compares the air conditioning requirements of high-rise office buildings with those of large centralized school complexes. A description of one particular air conditioning system provides information about the system's arrangement, functions, performance efficiency, and cost effectiveness. (MLF)

  15. Potential Evaluation of Solar Heat Assisted Desiccant Hybrid Air Conditioning System

    Science.gov (United States)

    Tran, Thien Nha; Hamamoto, Yoshinori; Akisawa, Atsushi; Kashiwagi, Takao

    The solar thermal driven desiccant dehumidification-absorption cooling hybrid system has superior advantage in hot-humid climate regions. The reasonable air processing of desiccant hybrid air conditioning system and the utility of clean and free energy make the system environment friendly and energy efficient. The study investigates the performance of the desiccant dehumidification air conditioning systems with solar thermal assistant. The investigation is performed for three cases which are combinations of solar thermal and absorption cooling systems with different heat supply temperature levels. Two solar thermal systems are used in the study: the flat plate collector (FPC) and the vacuum tube with compound parabolic concentrator (CPC). The single-effect and high energy efficient double-, triple-effect LiBr-water absorption cooling cycles are considered for cooling systems. COP of desiccant hybrid air conditioning systems are determined. The evaluation of these systems is subsequently performed. The single effect absorption cooling cycle combined with the flat plate collector solar system is found to be the most energy efficient air conditioning system.

  16. Dynamics of Peregrine combs and Peregrine walls in an inhomogeneous Hirota and Maxwell-Bloch system

    Science.gov (United States)

    Wang, Lei; Wang, Zi-Qi; Sun, Wen-Rong; Shi, Yu-Ying; Li, Min; Xu, Min

    2017-06-01

    Under investigation in this paper is an inhomogeneous Hirota-Maxwell-Bloch (IHMB) system which can describe the propagation of optical solitons in an erbium-doped optical fiber. The breather multiple births (BMBs) are derived with periodically varying group velocity dispersion (GVD) coefficients. Under large periodic modulations in the GVD coefficient of IHMB system, the Peregrine comb (PC) solution is produced, which can be viewed as the limiting case of the BMBs. When the amplitude of the modulation satisfies a special condition, the Peregrine wall (PW) that can be regarded as an intermediate state between rogue wave and PC is obtained. The effects of the third-order dispersion on the spatiotemporal characteristics of PCs and PWs are studied. Our results may be useful for the experimental control and manipulation of the formation of generalized Peregrine rogue waves in inhomogeneous erbium-doped optical fiber.

  17. DEVELOPMENT OF AUTOMATED SYSTEM OF CLIMATE CONDITIONS MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Novikova L.V.

    2017-12-01

    Full Text Available The scientific work is devoted to the analysis and development of the automated control system of the climatic conditions of the minites. The analysis of existing automated control systems is carried out, in particular attention is paid to the systems of climate control of greenhouses. The technical means of the control system are determined. As a platform, Arduino®Uno is selected.

  18. Automotive hexband antenna for AM/FM/GPS/SDARS and AMPS/PCS1900 cell phone in an only 65 mm high housing

    International Nuclear Information System (INIS)

    Kammerer, J; Reiter, L; Lindenmeier, S

    2013-01-01

    Nowadays cars are equipped frequently with typical 400 mm long active AM/FM antennas mounted on top close to the rear windshield. In [1], we presented a novel capacitive coupled helical antenna with a height of only 140 mm which performs equivalent to such an 400 mm long antenna. In the next step the antenna height has been reduced to only 56 mm in order to be placed in a low 65 mm housing in combination with other decoupled antennas. The measured results for AM/FM are close to the performance of a whip antenna of 900 mm length. The GPS and SDARS antennas are realized in a combination of two table-formed ring structures with a maximum gain for LHCP at 2339 MHz with 2.9 dBi in zenith and with 5.2 dBi in zenith for RHCP at 1575 MHz with GPS. The VSWR of the cell phone antenna is below 3 for AMPS and PCS1900.

  19. Differential Expression Analysis by RNA-Seq Reveals Perturbations in the Platelet mRNA Transcriptome Triggered by Pathogen Reduction Systems.

    Directory of Open Access Journals (Sweden)

    Abdimajid Osman

    Full Text Available Platelet concentrates (PCs are prepared at blood banks for transfusion to patients in certain clinical conditions associated with a low platelet count. To prevent transfusion-transmitted infections via PCs, different pathogen reduction (PR systems have been developed that inactivate the nucleic acids of contaminating pathogens by chemical cross-linking, a mechanism that may also affect platelets' nucleic acids. We previously reported that treatment of stored platelets with the PR system Intercept significantly reduced the level of half of the microRNAs that were monitored, induced platelet activation and compromised the platelet response to physiological agonists. Using genome-wide differential expression (DE RNA sequencing (RNA-Seq, we now report that Intercept markedly perturbs the mRNA transcriptome of human platelets and alters the expression level of >800 mRNAs (P<0.05 compared to other PR systems and control platelets. Of these, 400 genes were deregulated with DE corresponding to fold changes (FC ≥ 2. At the p-value < 0.001, as many as 147 genes were deregulated by ≥ 2-fold in Intercept-treated platelets, compared to none in the other groups. Finally, integrated analysis combining expression data for microRNA (miRNA and mRNA, and involving prediction of miRNA-mRNA interactions, disclosed several positive and inverse correlations between miRNAs and mRNAs in stored platelets. In conclusion, this study demonstrates that Intercept markedly deregulates the platelet mRNA transcriptome, concomitant with reduced levels of mRNA-regulatory miRNAs. These findings should enlighten authorities worldwide when considering the implementation of PR systems, that target nucleic acids and are not specific to pathogens, for the management of blood products.

  20. Design of a fast runback feature for PRISM control

    International Nuclear Information System (INIS)

    Wagner, W.K.; Rhow, S.K.; Daniel, W.R.; Dayal, Y.; Gaubatz, D.C.

    1988-01-01

    The nine power reactor inherently safe modules (PRISM) are controlled and their operation coordinated by a hierarchical, distributed, digital plant control system (PCS). This paper describes the fast runback features of the PCS. Fast runback consists of PCS directed reactor module shutdown with accompanying reductions of coolant flows. Analyses have shown that the PCS fast runback adequately terminates duty cycle events initiated in the balance of plant and the steam generating system, results in lower thermal shock to the reactor than scram, and reduces the number of scrams by approximately a factor of five

  1. New Fast Beam Conditions Monitoring (BCM1F) system for CMS

    Science.gov (United States)

    Zagozdzinska, A. A.; Bell, A. J.; Dabrowski, A. E.; Hempel, M.; Henschel, H. M.; Karacheban, O.; Przyborowski, D.; Leonard, J. L.; Penno, M.; Pozniak, K. T.; Miraglia, M.; Lange, W.; Lohmann, W.; Ryjov, V.; Lokhovitskiy, A.; Stickland, D.; Walsh, R.

    2016-01-01

    The CMS Beam Radiation Instrumentation and Luminosity (BRIL) project is composed of several systems providing the experiment protection from adverse beam conditions while also measuring the online luminosity and beam background. Although the readout bandwidth of the Fast Beam Conditions Monitoring system (BCM1F—one of the faster monitoring systems of the CMS BRIL), was sufficient for the initial LHC conditions, the foreseen enhancement of the beams parameters after the LHC Long Shutdown-1 (LS1) imposed the upgrade of the system. This paper presents the new BCM1F, which is designed to provide real-time fast diagnosis of beam conditions and instantaneous luminosity with readout able to resolve the 25 ns bunch structure.

  2. Integrability and boundary conditions of supersymmetric systems

    International Nuclear Information System (INIS)

    Yue Ruihong; Liang Hong

    1996-01-01

    By studying the solutions of the reflection equations, we find out a series of integrable supersymmetric systems with different boundary conditions. The Hamiltonian contains four free parameters which describe the contribution of the boundary terms

  3. The System-Synergetic Approach to Development of Banking Systems under Conditions of Financial Instability

    Directory of Open Access Journals (Sweden)

    Karcheva Ganna T.

    2015-03-01

    Full Text Available The aim of the article is to study the theoretical and practical aspects of using the system-synergetic approach to the development and functioning of banking systems under conditions of financial instability. It has been grounded that the theoretical foundations for the development of banking systems are based on the system approach, according to which the banking systems belong to a class of special complex dynamic, self-motivated and open systems with an integrated structure of subsystems and functions. The study of such systems should include two aspects — system-cybernetic and system-synergetic ones. It has been proved that under stationary conditions the banking system development goes on in accordance with the systemcybernetic model, which suggests the presence of a management subsystem, which functions are performed by the central bank. Under conditions of financial instability, in the pre-crisis, crisis and post-crisis periods to study the development of banking systems the system-synergetic approach taking into account the multi-variant and alternative development of the banking system at bifurcation points is used. The criteria of the banking system entering the phase of bifurcation based on assessing the volatility of the current liabilities and possibility of building an analytical trend have been determined. The methodical approaches to evaluating the synergistic effects and level of financial stability of the banking system have been suggested, experimental calculations have been made.

  4. Systemic conditions and treatments as risk for therapy with dental implants

    International Nuclear Information System (INIS)

    Arguedas Vega, Natalia; Alfaro Mayorga, Erika

    2013-01-01

    The possible risks for osseointegration are described in patients with specific systemic conditions, medical treatment such as radiation, cardiovascular diseases, HIV and smoking habit. The principal complications for osseointegration of diseases and systemic treatments are exposed. The review and search of the available literature are realized in databases. The scientific literature obtained from human studies has reported the survival of patients with dental implants. The implants are placed in patients with at least one of the conditions studied. The risks of the surgical procedures required for the placement of implants are analyzed in systemically compromised patients. Comparisons of patients with and without systemic conditions in controlled form have remained without analyzing. The level of evidence of absolute and relative contraindications has been low for the therapy with implants in patients with systemic diseases. The revised information is detailed according the systemic conditions, and each of them are evaluated separately [es

  5. Evolution of the ReadOut System of the ATLAS experiment

    CERN Document Server

    Borga, A; The ATLAS collaboration; Joos, M; Schumacher, J; Tremblet, L; Vandelli, W; Vermeulen, J; Werner, P; Wickens, F

    2014-01-01

    The ReadOut System (ROS) is a central and essential part of the ATLAS data-acquisition system. It receives and buffers event data accepted from all sub-detectors and first-level trigger subsystems. Event data are subsequently forwarded to the High-Level Trigger system and Event Builder via a GbE-based network. The ATLAS ROS will be completely renewed in view of the demanding conditions expected during LHC Run 2 and Run 3. The new ROS will consist of roughly 100 Linux-based 2U-high rack-mounted server PCs, each equipped with 2 PCIe I/O cards and four 10GbE interfaces. The FPGA-based PCIe I/O cards, developed by the ALICE collaboration, will be configured with ATLAS-specific firmware, called RobinNP. They will provide connectivity to about 2000 point-to-point optical links conveying the ATLAS event data. This dense configuration provides an excellent test bench for studying I/O efficiency and challenges in current COTS PC architectures with non-uniform memory and I/O access paths. In this paper the requirements...

  6. Evolution of the ReadOut System of the ATLAS experiment

    CERN Document Server

    Borga, A; The ATLAS collaboration; Green, B; Kugel, A; Joos, M; Panduro Vazquez, W; Schumacher, J; Teixeira-Dias, P; Tremblet, L; Vandelli, W; Vermeulen, J; Werner, P; Wickens, F

    2014-01-01

    The ReadOut System (ROS) is a central and essential part of the ATLAS DAQ system. It receives and buffers data of events accepted by the first-level trigger from all subdetectors and first-level trigger subsystems. Event data are subsequently forwarded to the High-Level Trigger system and Event Builder via a 1 GbE-based network. The ATLAS ROS is completely renewed in view of the demanding conditions expected during LHC Run 2 and Run 3, to replace obsolete technologies and space constraints require it to be compact. The new ROS will consist of roughly 100 Linux-based 2U high rack mounted server PCs, each equipped with 2 PCIe I/O cards and two four 10 GbE interfaces. The FPGA-based PCIe I/O cards, developed by the ALICE collaboration, will be configured with ATLAS-specific firmware, the so-called RobinNP firmware. They will provide the connectivity to about 2000 optical point-to-point links conveying the ATLAS event data. This dense configuration provides an excellent test bench for studying I/O efficiency and ...

  7. Weather conditions influence the number of psychiatric emergency room patients

    Science.gov (United States)

    Brandl, Eva Janina; Lett, Tristram A.; Bakanidze, George; Heinz, Andreas; Bermpohl, Felix; Schouler-Ocak, Meryam

    2017-12-01

    The specific impact of weather factors on psychiatric disorders has been investigated only in few studies with inconsistent results. We hypothesized that meteorological conditions influence the number of cases presenting in a psychiatric emergency room as a measure of mental health conditions. We analyzed the number of patients consulting the emergency room (ER) of a psychiatric hospital in Berlin, Germany, between January 1, 2008, and December 31, 2014. A total of N = 22,672 cases were treated in the ER over the study period. Meteorological data were obtained from a publicly available data base. Due to collinearity among the meteorological variables, we performed a principal component (PC) analysis. Association of PCs with the daily number of patients was analyzed with autoregressive integrated moving average model. Delayed effects were investigated using Granger causal modeling. Daily number of patients in the ER was significantly higher in spring and summer compared to fall and winter (p psychiatric patients consulting the emergency room. In particular, our data indicate lower patient numbers during very cold temperatures.

  8. Air conditioning systems as non-infectious health hazards inducing acute respiratory symptoms.

    Science.gov (United States)

    Gerber, Alexander; Fischer, Axel; Willig, Karl-Heinz; Groneberg, David A

    2006-04-01

    Chronic and acute exposure to toxic aerosols belongs to frequent causes of airway diseases. However, asthma attacks due to long-distance inhalative exposure to organic solvents, transmitted via an air condition system, have not been reported so far. The present case illustrates the possibility of air conditioning systems as non-infectious health hazards in occupational medicine. So far, only infectious diseases such as legionella pneumophila pneumonia have commonly been associated to air-conditioning exposures but physicians should be alert to the potential of transmission of toxic volatile substances via air conditioning systems. In view of the events of the 11th of September 2001 with a growing danger of large building terrorism which may even use air conditioning systems to transmit toxins, facility management security staff should be alerted to possible non-infectious toxic health hazards arising from air-conditioning systems.

  9. Stuxnet. Lessons learned?; Stuxnet. Lessons learned? Angriff auf die Leittechnik

    Energy Technology Data Exchange (ETDEWEB)

    Beirer, Stephan [GAI Netconsult GmbH, Berlin (Germany). Fach IT-Sicherheit in Prozesssteuerungsumgebungen

    2011-01-10

    Stuxnet, a malware developed to attack Siemens PCS7 process control systems has caused a stir in the last months. Further investigations revealed that this malware was targeted on a specific PCS7 control system installation and that all other other PCS7 systems are not threatened. It is, however, the question what long-term impacts for the information security of modern process control systems result from the Stuxnet worm and which security measures control system operators will have to implement after this incident. (orig.)

  10. Power conditioning system for a nuclear reactor

    International Nuclear Information System (INIS)

    Higashigawa, Yuichi; Joge, Toshio.

    1981-01-01

    Purpose: To provide a power conditioning system for a BWR type reactor which has a function to be automatically operated within a range that the relationship between the heat power of the reactor and the electric power of an electric generator does not lose the safety of fuel by eliminating the unnecessary fluctuation of the power of the reactor. Constitution: A load request error signal fed from a conventional turbine control system to recirculation flow regulator is eliminated, and a reactor power conditioning system is newly provided, to which an electric generator power signal, a reactor average power area monitor signal and a load request signal are inputted. Thus, the load request signal is compared directly with the electric power of the electric generator, the recirculation flow rate is controlled by the compared result, and whether the correlation between the heat power of the reqctor and the electric power of the generator satisfies the correlation determined to prove the safety of fuel or not is checked. If this correlation is satisfied, the recirculation flow rate is merely automatically controlled. (Yoshino, Y.)

  11. An expert fault diagnosis system for vehicle air conditioning product development

    NARCIS (Netherlands)

    Tan, C.F.; Tee, B.T.; Khalil, S.N.; Chen, W.; Rauterberg, G.W.M.

    2015-01-01

    The paper describes the development of the vehicle air-conditioning fault diagnosis system in automotive industries with expert system shell. The main aim of the research is to diagnose the problem of new vehicle air-conditioning system development process and select the most suitable solution to

  12. Outsourcing e geração de valor na indústria de computadores pessoais (PCs: estudo de múltiplos casos The disruption of the Brazilian Personal Computer (PC industry: a multiple case study

    Directory of Open Access Journals (Sweden)

    Fernando José Barbin Laurindo

    2003-12-01

    Full Text Available Apesar de o conceito de computador pessoal (personal computer - PC ter surgido nos anos 70, essa indústria realmente deslanchou somente após o lançamento do IBM PC, em 1981. Por meio de uma agressiva estratégia de outsourcing, a IBM rapidamente conquistou o mercado, mas esta estratégia também causou perda de competências internas para seus principais parceiros, Intel e Microsoft, bem como outros revendedores autônomos. No Brasil, atualmente, a indústria de PCs está relegada à montagem de kits importados e também à manufatura das etapas finais do processo de produção de componentes, com pouco valor agregado localmente. Após o término da reserva de mercado, marcado pela súbita abertura aos concorrentes externos, houve desmantelamento da indústria brasileira de PCs e de semicondutores, nos elos de maior valor agregado dessa cadeia. Para obter inserção nas cadeias globais, as empresas brasileiras precisam atingir qualificação nos critérios de desempenho, a fim de participar dos processos de outsourcing. Este artigo visa, por meio de um aparato teórico que relaciona aspectos de outsourcing, inovação, valor e evolução da indústria de PCs, a investigar os impactos desses aspectos na competitividade da indústria de PCs do Brasil e as repercussões para seu crescimento e inserção no mercado global. A abordagem metodológica adotada foi estudo de múltiplos casos, com os seguintes critérios de seleção: diferentes papéis na cadeia de valor, grau de verticalização, principal mercado visado e tamanho da empresa.Although the personal computer (PC appeared in the seventies, this industry really boomed only after IBM launched its PC, in 1981. Through an aggressive outsourcing strategy, IBM rapidly conquered the market, but this strategy also caused lost of internal competences to its main partners, Intel and Microsoft and also to autonomous vendors. Many PC manufacturers have appeared since then. In Brazil, nowadays, PC

  13. Digital image display system for emergency room

    International Nuclear Information System (INIS)

    Murry, R.C.; Lane, T.J.; Miax, L.S.

    1989-01-01

    This paper reports on a digital image display system for the emergency room (ER) in a major trauma hospital. Its objective is to reduce radiographic image delivery time to a busy ER while simultaneously providing a multimodality capability. Image storage, retrieval, and display will also be facilitated with this system. The system's backbone is a token-ring network of RISC and personal computers. The display terminals are higher- function RISC computers with 1,024 2 color or gray-scale monitors. The PCs serve as administrative terminals. Nuclear medicine, CT, MR, and digitized film images are transferred to the image display system

  14. Methionine metabolism after portacaval shunt in the rat

    International Nuclear Information System (INIS)

    Benjamin, L.E.; Steele, R.D.

    1985-01-01

    The effect of portacaval shunt (PCS) on methionine metabolism in the rat was investigated. Male Sprague-Dawley rats were subjected to PCS and maintained on an 18% casein diet. Growth curves of operated rats were similar to controls. PCS rats excreted more urinary 35 SO 4 and less [ 35 S]taurine than controls after intraperitoneal injection of 0.3 mmol/100 g [ 35 S]methionine or [ 35 S]cysteine. Total urinary taurine excretion was similar in PCS and control rats after a methionine or cysteine load; however, under basal conditions PCS rats had higher urinary taurine levels than controls, indicating that PCS may cause the taurine pool to be expanded. Hepatic methionine, S-adenosylmethionine, and cysteine pools were significantly decreased in PCS rats, while S-adenosylhomocysteine levels were unchanged. Relative rates of transsulfuration in PCS and control rats were studied by following the decrease in the 3 H-to- 35 S ratio in liver protein after injection of [methyl-3H]methionine and [ 35 S]methionine, and no difference in flux of 35 S from [ 35 S]methionine to [ 35 S]cysteine was found. Similarly, total hepatic activities of methionine adenosyltransferase, cystathionine synthase, and cystathionine gamma-lyase were unchanged in PCS rats. These results indicate that altered methionine metabolism in PCS rats is not explained by changes in conversion of methionine to cysteine via the transsulfuration pathway

  15. Exergy characteristics of a ceiling-type residential air conditioning system operating under different climatic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Arif [Dept. of Mechanical Engineering, Ceyhan Engineering Faculty, Cukurova University, Adana (Turkmenistan)

    2016-11-15

    In this study an energy and exergy analysis of a Ceiling-type residential air conditioning (CTRAC) system operating under different climatic conditions have been investigated for provinces within the different geographic regions of Turkey. Primarily, the hourly cooling load capacities of a sample building (Q{sub evap}) during the months of April, May, June, July, August and September were determined. The hourly total heat gain of the sample building was determined using the Hourly analysis program (HAP). The Coefficient of performance (COP), exergy efficiency (η) and exergy destruction (Ex{sub dest}) values for the whole system and for each component were obtained. The results showed that lower atmospheric temperature (T{sub atm}) influenced the performance of the system and each of its components.

  16. [An Exploration of Working Conditions and Flexible System for Hospital Nurses].

    Science.gov (United States)

    Huang, Chung-I; Yu, Chien; Yu, Chin-Cheh

    2016-04-01

    The lack of sufficient numbers of professional nurses in the healthcare system in Taiwan is an issue that affects the sustainability of this system and that relates closely to working conditions. The present study explores the expectations that nurses hold with regard to working conditions and the operation of a flexible system in hospitals. A literature review and focus-group interviews were used to develop the questionnaire Working Conditions and Flexible System. A total of 1,150 copies of this questionnaire were distributed to practicing nurses using stratified random sampling, with 1,146 valid copies returned for a valid recovery rate of 99.65%. The results show that the expectations of participants concerning working conditions and a flexible system focus on the 6 factors of task, numerical, divisional, temporal, wages, and leading flexibility. The total mean was 4.35 (SD=0.42). The means for the 6 types of flexibility were all greater than 4.0. Participants deemed flexibility to be of high importance. The demographic variables hospital, work location, age, education level, work position, work unit, and total work years all affected the 6 types of flexibility significantly. The present study supports that the retention of nurses is significantly associated with working conditions and the operation of a flexible system. Administrators and mangers must create positive working conditions and a flexible system in order to enhance the retention and career development of nurses.

  17. Telemetric measurement system of beehive environment conditions

    Science.gov (United States)

    Walendziuk, Wojciech; Sawicki, Aleksander

    2014-11-01

    This work presents a measurement system of beehive environmental conditions. The purpose of the device is to perform measurements of parameters such as ambient temperature, atmospheric pressure, internal temperature, humidity and sound level. The measured values were transferred to the MySQL database, which is located on an external server, with the use of GPRS protocol. A website presents the measurement data in the form of tables and graphs. The study also shows exemplary results of environmental conditions measurements recorded in the beehive by hour cycle.

  18. Spontaneous emission of semiconductor quantum dots in inverse opal SiO2 photonic crystals at different temperatures.

    Science.gov (United States)

    Yang, Peng; Yang, Yingshu; Wang, Yinghui; Gao, Jiechao; Sui, Ning; Chi, Xiaochun; Zou, Lu; Zhang, Han-Zhuang

    2016-02-01

    The photoluminescence (PL) characteristics of CdSe quantum dots (QDs) infiltrated into inverse opal SiO2 photonic crystals (PCs) are systemically studied. The special porous structure of inverse opal PCs enhanced the thermal exchange rate between the CdSe QDs and their surrounding environment. Finally, inverse opal SiO2 PCs suppressed the nonlinear PL enhancement of CdSe QDs in PCs excited by a continuum laser and effectively modulated the PL characteristics of CdSe QDs in PCs at high temperatures in comparison with that of CdSe QDs out of PCs. The final results are of benefit in further understanding the role of inverse opal PCs on the PL characteristics of QDs. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Calibrated photostimulated luminescence is an effective approach to identify irradiated orange during storage

    Science.gov (United States)

    Jo, Yunhee; Sanyal, Bhaskar; Chung, Namhyeok; Lee, Hyun-Gyu; Park, Yunji; Park, Hae-Jun; Kwon, Joong-Ho

    2015-06-01

    Photostimulated luminescence (PSL) has been employed as a fast screening method for various irradiated foods. In this study the potential use of PSL was evaluated to identify oranges irradiated with gamma ray, electron beam and X-ray (0-2 kGy) and stored under different conditions for 6 weeks. The effects of light conditions (natural light, artificial light, and dark) and storage temperatures (4 and 20 °C) on PSL photon counts (PCs) during post-irradiation periods were studied. Non-irradiated samples always showed negative values of PCs, while irradiated oranges exhibited intermediate results after first PSL measurements. However, the irradiated samples had much higher PCs. The PCs of all the samples declined as the storage time increased. Calibrated second PSL measurements showed PSL ratio <10 for the irradiated samples after 3 weeks of irradiation confirming their irradiation status in all the storage conditions. Calibrated PSL and sample storage in dark at 4 °C were found out to be most suitable approaches to identify irradiated oranges during storage.

  20. Design Guideline for Primary Heat Exchanger in a Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sunil; Seo, Kyoung-Woo; Kim, Seong-Hoon; Chi, Dae-Young; Park, Cheol [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this paper, analytical study is conducted to track the variation of the PCS outlet temperature in conditions of the constant core power and constant SCS inlet temperature. The PCS circulates demineralized water to remove the heat generated in reactor core. The heat is transferred to the cold water of the SCS through the primary heat exchanger. In JRTR, Plate-type Heat Exchanger (PHE) was used as the primary heat exchanger. The cooling tower automatically sets the SCS inlet temperature constant by fan speed control. The flow rate of SCS is adjusted to be identical with the PCS flow rate. To design the PHE, the inlet and outlet temperatures and the flow rates for both systems should be determined. The flow rate has the allowable band for the safe operation from the lower limit to upper limit resulting in different temperature distribution in the PHE. Specially, the PCS outlet temperature which is the core inlet temperature is used for a safety parameter for the reactor shutdown. Therefore, we need to figure out which limit for the flow rate should be used from the conservative point of view. At 200 kg/s of PCS and SCS flow rates, the inlet and outlet temperatures are 41.3℃and 34℃, respectively. With increase of the flow rate, both of PCS inlet and outlet temperatures decrease to 33.6℃ and 39.9℃. This result means the low limit of the allowable flow band should be used for the conservative design of primary heat exchanger. If the upper limit of the allowable flow band is used, the PCS outlet temperature which is the safety parameter used for the reactor shutdown increases with decrease of the flow rate.

  1. Design Guideline for Primary Heat Exchanger in a Research Reactor

    International Nuclear Information System (INIS)

    Lee, Sunil; Seo, Kyoung-Woo; Kim, Seong-Hoon; Chi, Dae-Young; Park, Cheol

    2016-01-01

    In this paper, analytical study is conducted to track the variation of the PCS outlet temperature in conditions of the constant core power and constant SCS inlet temperature. The PCS circulates demineralized water to remove the heat generated in reactor core. The heat is transferred to the cold water of the SCS through the primary heat exchanger. In JRTR, Plate-type Heat Exchanger (PHE) was used as the primary heat exchanger. The cooling tower automatically sets the SCS inlet temperature constant by fan speed control. The flow rate of SCS is adjusted to be identical with the PCS flow rate. To design the PHE, the inlet and outlet temperatures and the flow rates for both systems should be determined. The flow rate has the allowable band for the safe operation from the lower limit to upper limit resulting in different temperature distribution in the PHE. Specially, the PCS outlet temperature which is the core inlet temperature is used for a safety parameter for the reactor shutdown. Therefore, we need to figure out which limit for the flow rate should be used from the conservative point of view. At 200 kg/s of PCS and SCS flow rates, the inlet and outlet temperatures are 41.3℃and 34℃, respectively. With increase of the flow rate, both of PCS inlet and outlet temperatures decrease to 33.6℃ and 39.9℃. This result means the low limit of the allowable flow band should be used for the conservative design of primary heat exchanger. If the upper limit of the allowable flow band is used, the PCS outlet temperature which is the safety parameter used for the reactor shutdown increases with decrease of the flow rate

  2. Fiber optic neutron imaging system: calibration

    International Nuclear Information System (INIS)

    Malone, R.M.; Gow, C.E.; Thayer, D.R.

    1981-01-01

    Two neutron imaging experiments using fiber optics have been performed at the Nevada Test Site. In each experiment, an array of scintillator fluor tubes is exposed to neutrons. Light is coupled out through radiation resistant PCS fibers (8-m long) into high-bandwidth, graded index fibers. For image reconstruction to be accurate, common timing differences and transmission variations between fiber optic channels are needed. The calibration system featured a scanning pulsed dye laser, a specially designed fiber optic star coupler, a tektronix 7912AD transient digitizer, and a DEC PDP 11/34 computing system

  3. Conditional Toxin Splicing Using a Split Intein System.

    Science.gov (United States)

    Alford, Spencer C; O'Sullivan, Connor; Howard, Perry L

    2017-01-01

    Protein toxin splicing mediated by split inteins can be used as a strategy for conditional cell ablation. The approach requires artificial fragmentation of a potent protein toxin and tethering each toxin fragment to a split intein fragment. The toxin-intein fragments are, in turn, fused to dimerization domains, such that addition of a dimerizing agent reconstitutes the split intein. These chimeric toxin-intein fusions remain nontoxic until the dimerizer is added, resulting in activation of intein splicing and ligation of toxin fragments to form an active toxin. Considerations for the engineering and implementation of conditional toxin splicing (CTS) systems include: choice of toxin split site, split site (extein) chemistry, and temperature sensitivity. The following method outlines design criteria and implementation notes for CTS using a previously engineered system for splicing a toxin called sarcin, as well as for developing alternative CTS systems.

  4. Initial surface film on magnesium metal: A characterization by X-ray photoelectron spectroscopy (XPS) and photocurrent spectroscopy (PCS)

    International Nuclear Information System (INIS)

    Santamaria, M.; Di Quarto, F.; Zanna, S.; Marcus, P.

    2007-01-01

    A detailed investigation of the initial film grown on mechanically polished Mg electrodes has been carried out by ex situ X-ray Photoelectron Spectroscopy (XPS) and in situ Photocurrent Spectroscopy (PCS), allowing to reach a detailed picture of the passive layer structure. The XPS data show that the films formed soon after mechanical treatment and immersion in aqueous electrolyte have a bilayer structure, consisting of an ultra-thin MgO inner layer (∼2.5 nm) and a Mg(OH) 2 external layer. The thickness of the Mg(OH) 2 layer is a function of immersion time and solution temperature. After mechanical treatment and immersion in aqueous solution at room temperature, the MgO/Mg(OH) 2 layer in some area of electrodes is so thin to allow an electron photoemission process from the Mg Fermi level to the electrolyte conduction band. Only internal photoemission processes are evidenced for Mg electrodes aged in NaOH at 80 deg. C, due the formation of a thicker Mg(OH) 2 layer. From anodic photocurrent spectra an optical band gap of ∼4.25 eV has been estimated for Mg(OH) 2 , lower with respect to the optical gap of the corresponding anhydrous counterpart

  5. MoZis: mobile zoo information system: a case study for the city of Osnabrueck

    Science.gov (United States)

    Michel, Ulrich

    2007-10-01

    This paper describes a new project of the Institute for Geoinformatics and Remote Sensing, funded by the German Federal Foundation for the Environment (DBU, Deutsche Bundesstiftung Umwelt www.dbu.de). The goal of this project is to develop a mobile zoo information system for Pocket PCs and Smart phones. Visitors of the zoo will be able to use their own mobile devices or use Pocket PCs, which could be borrowed from the zoo to navigate around the zoo's facilities. The system will also provide additional multimedia based information such as audio-based material, animal video clips, and maps of their natural habitat. People could have access to the project at the zoo via wireless local area network or by downloading the necessary files using a home internet connection. Our software environment consists of proprietary and non-proprietary software solutions in order to make it as flexible as possible. Our first prototype was developed with Visual Studio 2003 and Visual Basic.Net.

  6. Modern Embedded Computing Designing Connected, Pervasive, Media-Rich Systems

    CERN Document Server

    Barry, Peter

    2012-01-01

    Modern embedded systems are used for connected, media-rich, and highly integrated handheld devices such as mobile phones, digital cameras, and MP3 players. All of these embedded systems require networking, graphic user interfaces, and integration with PCs, as opposed to traditional embedded processors that can perform only limited functions for industrial applications. While most books focus on these controllers, Modern Embedded Computing provides a thorough understanding of the platform architecture of modern embedded computing systems that drive mobile devices. The book offers a comprehen

  7. OPSAID improvements and capabilities report.

    Energy Technology Data Exchange (ETDEWEB)

    Halbgewachs, Ronald D.; Chavez, Adrian R.

    2011-08-01

    Process Control System (PCS) and Industrial Control System (ICS) security is critical to our national security. But there are a number of technological, economic, and educational impediments to PCS owners implementing effective security on their systems. Sandia National Laboratories has performed the research and development of the OPSAID (Open PCS Security Architecture for Interoperable Design), a project sponsored by the US Department of Energy Office of Electricity Delivery and Energy Reliability (DOE/OE), to address this issue. OPSAID is an open-source architecture for PCS/ICS security that provides a design basis for vendors to build add-on security devices for legacy systems, while providing a path forward for the development of inherently-secure PCS elements in the future. Using standardized hardware, a proof-of-concept prototype system was also developed. This report describes the improvements and capabilities that have been added to OPSAID since an initial report was released. Testing and validation of this architecture has been conducted in another project, Lemnos Interoperable Security Project, sponsored by DOE/OE and managed by the National Energy Technology Laboratory (NETL).

  8. Boundary conditions for open quantum systems driven far from equilibrium

    Science.gov (United States)

    Frensley, William R.

    1990-07-01

    This is a study of simple kinetic models of open systems, in the sense of systems that can exchange conserved particles with their environment. The system is assumed to be one dimensional and situated between two particle reservoirs. Such a system is readily driven far from equilibrium if the chemical potentials of the reservoirs differ appreciably. The openness of the system modifies the spatial boundary conditions on the single-particle Liouville-von Neumann equation, leading to a non-Hermitian Liouville operator. If the open-system boundary conditions are time reversible, exponentially growing (unphysical) solutions are introduced into the time dependence of the density matrix. This problem is avoided by applying time-irreversible boundary conditions to the Wigner distribution function. These boundary conditions model the external environment as ideal particle reservoirs with properties analogous to those of a blackbody. This time-irreversible model may be numerically evaluated in a discrete approximation and has been applied to the study of a resonant-tunneling semiconductor diode. The physical and mathematical properties of the irreversible kinetic model, in both its discrete and its continuum formulations, are examined in detail. The model demonstrates the distinction in kinetic theory between commutator superoperators, which may become non-Hermitian to describe irreversible behavior, and anticommutator superoperators, which remain Hermitian and are used to evaluate physical observables.

  9. Application of solar energy to air conditioning systems

    Science.gov (United States)

    Nash, J. M.; Harstad, A. J.

    1976-01-01

    The results of a survey of solar energy system applications of air conditioning are summarized. Techniques discussed are both solar powered (absorption cycle and the heat engine/Rankine cycle) and solar related (heat pump). Brief descriptions of the physical implications of various air conditioning techniques, discussions of status, proposed technological improvements, methods of utilization and simulation models are presented, along with an extensive bibliography of related literature.

  10. The Conditional Entropy Power Inequality for Bosonic Quantum Systems

    DEFF Research Database (Denmark)

    de Palma, Giacomo; Trevisan, Dario

    2018-01-01

    We prove the conditional Entropy Power Inequality for Gaussian quantum systems. This fundamental inequality determines the minimum quantum conditional von Neumann entropy of the output of the beam-splitter or of the squeezing among all the input states where the two inputs are conditionally...... independent given the memory and have given quantum conditional entropies. We also prove that, for any couple of values of the quantum conditional entropies of the two inputs, the minimum of the quantum conditional entropy of the output given by the conditional Entropy Power Inequality is asymptotically...... achieved by a suitable sequence of quantum Gaussian input states. Our proof of the conditional Entropy Power Inequality is based on a new Stam inequality for the quantum conditional Fisher information and on the determination of the universal asymptotic behaviour of the quantum conditional entropy under...

  11. Robust Road Condition Detection System Using In-Vehicle Standard Sensors

    Directory of Open Access Journals (Sweden)

    Juan Jesús Castillo Aguilar

    2015-12-01

    Full Text Available The appearance of active safety systems, such as Anti-lock Braking System, Traction Control System, Stability Control System, etc., represents a major evolution in road safety. In the automotive sector, the term vehicle active safety systems refers to those whose goal is to help avoid a crash or to reduce the risk of having an accident. These systems safeguard us, being in continuous evolution and incorporating new capabilities continuously. In order for these systems and vehicles to work adequately, they need to know some fundamental information: the road condition on which the vehicle is circulating. This early road detection is intended to allow vehicle control systems to act faster and more suitably, thus obtaining a substantial advantage. In this work, we try to detect the road condition the vehicle is being driven on, using the standard sensors installed in commercial vehicles. Vehicle models were programmed in on-board systems to perform real-time estimations of the forces of contact between the wheel and road and the speed of the vehicle. Subsequently, a fuzzy logic block is used to obtain an index representing the road condition. Finally, an artificial neural network was used to provide the optimal slip for each surface. Simulations and experiments verified the proposed method.

  12. Robust Road Condition Detection System Using In-Vehicle Standard Sensors.

    Science.gov (United States)

    Castillo Aguilar, Juan Jesús; Cabrera Carrillo, Juan Antonio; Guerra Fernández, Antonio Jesús; Carabias Acosta, Enrique

    2015-12-19

    The appearance of active safety systems, such as Anti-lock Braking System, Traction Control System, Stability Control System, etc., represents a major evolution in road safety. In the automotive sector, the term vehicle active safety systems refers to those whose goal is to help avoid a crash or to reduce the risk of having an accident. These systems safeguard us, being in continuous evolution and incorporating new capabilities continuously. In order for these systems and vehicles to work adequately, they need to know some fundamental information: the road condition on which the vehicle is circulating. This early road detection is intended to allow vehicle control systems to act faster and more suitably, thus obtaining a substantial advantage. In this work, we try to detect the road condition the vehicle is being driven on, using the standard sensors installed in commercial vehicles. Vehicle models were programmed in on-board systems to perform real-time estimations of the forces of contact between the wheel and road and the speed of the vehicle. Subsequently, a fuzzy logic block is used to obtain an index representing the road condition. Finally, an artificial neural network was used to provide the optimal slip for each surface. Simulations and experiments verified the proposed method.

  13. Nontrivial Solution of Fractional Differential System Involving Riemann-Stieltjes Integral Condition

    Directory of Open Access Journals (Sweden)

    Ge-Feng Yang

    2012-01-01

    differential system involving the Riemann-Stieltjes integral condition, by using the Leray-Schauder nonlinear alternative and the Banach contraction mapping principle, some sufficient conditions of the existence and uniqueness of a nontrivial solution of a system are obtained.

  14. Federal Emergency Management Information System (FEMIS) system administration guide, version 1.4.5

    Energy Technology Data Exchange (ETDEWEB)

    Arp, J.A.; Burnett, R.A.; Carter, R.J. [and others

    1998-06-26

    The Federal Emergency Management Information Systems (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the US Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are connected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication, data distribution, and notification functionality necessary to operate FEMIS in a networked, client/server environment. The UNIX server provides an Oracle relational database management system (RDBMS) services, ARC/INFO GIS (optional) capabilities, and basic file management services. PNNL developed utilities that reside on the server include the Notification Service, the Command Service that executes the evacuation model, and AutoRecovery. To operate FEMIS, the Application Software must have access to a site specific FEMIS emergency management database. Data that pertains to an individual EOC`s jurisdiction is stored on the EOC`s local server. Information that needs to be accessible to all EOCs is automatically distributed by the FEMIS

  15. The opinion of Turkish cardiologists on current malpractice system and an alternative patient compensation system proposal: PCS study group.

    Science.gov (United States)

    Olcay, Ayhan; Emren, Sadık Volkan; Babür Güler, Gamze; Güler, Ekrem; Ertunç, Vedat; Berilgen, Rida; Aslan, Abdullah; Şimşek, Ersin Çağrı; Gölcük, Şükriye Ebru; Yalın, Kıvanç

    2017-10-01

    Cardiologists participate in the diagnosis and interventional treatment of numerous high-risk patients. The goal of this study was to investigate how the current malpractice system in Turkey influences cardiologists' diagnostic and interventional behavior and to obtain their opinions about an alternative patient compensation system. The present cross-sectional study assessed the practice of defensive medicine among cardiologists who are actively working in various types of workplace within the Turkish healthcare system. A 24-item questionnaire was distributed to cardiology residents, specialists, and academics in Turkey in print format, by electronic mail, or via cell phone message. A total of 253 cardiologists responded to the survey. Among them, 29 (11.6%) had been sued for malpractice claims in the past. Of the cardiologists who had been sued, 2 (6.9%) had been ordered to pay financial compensation, and 1 (3.4%) was given a sentence of imprisonment due to negligence. In all, 132 (52.8%) of the surveyed cardiologists reported that they had changed their practices due to fear of litigation, and 232 (92.8%) reported that they would prefer the new proposed patient compensation system to the current malpractice system. Among the cardiologists surveyed, 78.8% indicated that malpractice fear had affected their decision-making with regard to requesting computed tomography angiography or thallium scintigraphy, 71.6% for coronary angiography, 20% for stent implantation, and 83.2% for avoiding treating high-risk patients. The results of this survey demonstrated that cardiologists may request unnecessary tests and perform unneeded interventions due to the fear of malpractice litigation fear. Many also avoid high-risk patients and interventions. The majority indicated that they would prefer the proposed alternative patient compensation system to the current malpractice system.

  16. Air conditioning systems to clean radioactive air

    International Nuclear Information System (INIS)

    Ganz, G.

    1987-01-01

    The author reports a study by the Institutes fuer Klimatechnik and Umweltschutz Giessen that shows that air conditioning systems not only make the atmosphere more comfortable, they also extract dust particles. This cleaning action is also valid for radioactively contaminated air. (G.T.H./Auth.)

  17. Sensory evaluation of heating and air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Evin, F.; Siekierski, E. [Electricite de France, Research and Development Division, Les Renardieres, Moret Sur Loing (France)

    2002-07-01

    Existing standards and models, such as ISO 7730 or the work of Fanger [Thermal Comfort], are not sufficient to characterise the satisfaction and pleasantness of end-users provided by heating or air conditioning systems. For this reason Electricite de France (EDF) has initiated a project with the aim of using sensory evaluation techniques in the design of HVAC systems. Sensory evaluation has been used for more than 30 years in the food industry, and now involves the cosmetics, the phone and the automotive industries. It is based on a dual evaluation: sensation measurements carried out by a small panel of trained expert assessors; preference studies performed by a large panel of representative consumers. A correlation between the data of both studies is then used to explain the preferences in terms of sensations (preference mapping). The first experiments performed in 1999 and 2000 have provided lists of descriptors of thermal sensation and acoustic sensation associated with heating and air conditioning appliances. They show that it is possible to define discriminative descriptors, to train a panel and to reliably quantify these descriptors. It is then possible to draw the sensory profiles of different heating, ventilation and air conditioning (HVAC) systems. The future experimental laboratory that EDF has decided to build is also presented, where the trained panels and end-users will evaluate the sensations and the preferences of real systems in eight 'realistic environmental chambers' designed, furnished and decorated like offices and flats. (author)

  18. Performance study of desiccant coated heat exchanger air conditioning system in winter

    International Nuclear Information System (INIS)

    Ge, T.S.; Dai, Y.J.; Wang, R.Z.

    2016-01-01

    Highlights: • Performance of desiccant coated heat exchanger AC system is predicted. • Effects of main operation parameters and climatic conditions are discussed. • Regeneration temperature of 30 °C is recommended under simulation condition. • Higher ambient humidity ratio results in increased humidity ratio of supply air. • Temperature of ambient air has neglectable effect on supply air. - Abstract: Conventional air source heat pump system faces several challenges when adopted in winter season. Solid desiccant air conditioning system can provide humidification and heating power simultaneously and can be driven by low grade thermal energy; it provides a good alternative for air source heat pump systems. However, conventional solid desiccant air conditioning system adopts desiccant wheel with high cost as core component, which hinders the development of such system. Recently, desiccant coated heat exchanger (DCHE) with low initial cost and high efficiency was developed and this paper aims to investigate performance of DCHE air conditioning system adopted in Shanghai winter season. Performance of the system is predicted by a developed mathematical model where supply air states, mass of humidification and coefficient of performance (COP) are adopted as performance indices to evaluate the feasibility and energy utilization ratio of the system. Effects of regeneration water temperature on system performance are analyzed. It is found that under the simulation condition, relatively low regeneration temperature (such as 20 °C) cannot meet the designed standard and relatively high regeneration temperature (such as 40 °C) provides too much extra heating power, thus moderate regeneration temperature around 30 °C is recommended. Meanwhile, switch time is a crucial operation parameter for the system to obtain satisfied supply air, switch time from 40 s to 80 s and from 70 s to 240 s are recommended for transient and average supply air states, respectively. Both

  19. A VME-based accumulation, control and supervising system for neutron texture measurements

    International Nuclear Information System (INIS)

    Kirilov, A.S.; Heinitz, J.; Korobchenko, M.L.; Rezaev, V.E.; Sirotin, A.P.

    1997-01-01

    Nowadays VME-based systems to control neutron measurement instruments are forcing out those built with PC and CAMAC. One of several alternative solutions is presented here. Its main feature is the implementation of the entire system on the VME site. Both the hardware and the software parts are considered. The instrument can be controlled locally or remotely via local network (even from PCs) with a modern-styled graphical user interface

  20. Fault trees for diagnosis of system fault conditions

    International Nuclear Information System (INIS)

    Lambert, H.E.; Yadigaroglu, G.

    1977-01-01

    Methods for generating repair checklists on the basis of fault tree logic and probabilistic importance are presented. A one-step-ahead optimization procedure, based on the concept of component criticality, minimizing the expected time to diagnose system failure is outlined. Options available to the operator of a nuclear power plant when system fault conditions occur are addressed. A low-pressure emergency core cooling injection system, a standby safeguard system of a pressurized water reactor power plant, is chosen as an example illustrating the methods presented

  1. Alterations in sulfur and nitrogen metabolism in rats with portacaval shunts

    International Nuclear Information System (INIS)

    Benjamin, L.E.

    1985-01-01

    The effect of portacaval shunt (PCS) on methionine and cysteine metabolism was investigated. PCS rats excreted more urinary [ 35 S]sulfate and less [ 35 S]taurine than controls after injection of [ 35 S]methionine of [ 35 S]cysteine. Total urinary taurine excretion was unchanged. Under basal conditions PCS rats excreted more taurine than controls. Relative rates of transsulfuration in PCS and control rats were studied, and no difference in flux of 35 S from methionine to cysteine was found. Total hepatic activities of three transsulfuration pathway enzymes were also unchanged after PCS. In contrast, hepatic activities of three cysteine-oxidizing enzymes were depressed after PCS, suggesting that changes in hepatic metabolism after PCS are selective. PCS rats fed a high (60%) casein diet ate less and took longer to recover their preoperative body weight than controls. All PCS rats had higher plasma ammonia and urinary orotic acid levels than controls. Increasing dietary protein elevated plasma ammonia and urinary orotic acid to a greater extent in PCS rats. After injection of [ 35 S]methionine or [ 35 S]cysteine, urinary 35 S and [ 35 S]sulfate excretion increased and [ 35 S]taurine an total taurine excretion decreased in all rats fed 60% casein, but the effect was greater in PCS rats. Changes in cysteine sulfinate decarboxylase activity in rats fed a high protein diet was examined. Activity decreased 95% in rats fed diets containing between 18 and 75% casein. The effect was observed after feeding a 60% casein diet for 2 days and was reversed when rats were refed an 18% casein diet

  2. Evolution of the SOFIA tracking control system

    Science.gov (United States)

    Fiebig, Norbert; Jakob, Holger; Pfüller, Enrico; Röser, Hans-Peter; Wiedemann, Manuel; Wolf, Jürgen

    2014-07-01

    The airborne observatory SOFIA (Stratospheric Observatory for Infrared Astronomy) is undergoing a modernization of its tracking system. This included new, highly sensitive tracking cameras, control computers, filter wheels and other equipment, as well as a major redesign of the control software. The experiences along the migration path from an aged 19" VMbus based control system to the application of modern industrial PCs, from VxWorks real-time operating system to embedded Linux and a state of the art software architecture are presented. Further, the concept is presented to operate the new camera also as a scientific instrument, in parallel to tracking.

  3. Switching conditions in the electric power system

    International Nuclear Information System (INIS)

    Tsukushi, M.; Hirasawa, K.; Kurosawa, Y.

    1991-01-01

    This paper reports that a circuit breaker must be capable of making, carrying, and interrupting the current under both normal and abnormal conditions, especially in the case of a short-circuit fault. Before installing a circuit breaker, it is necessary to estimate the maximum short-circuit current that can occur in the electric power system and then select a circuit breaker that can interrupt and make the estimated current. Many types of short-circuit faults occur in electric power systems

  4. Engineering development of an HTS floating coil for the Mini-RT project

    International Nuclear Information System (INIS)

    Yanagi, Nagato; Mito, Toshiyuki; Morikawa, Junji

    2004-01-01

    A magnetically-levitated superconducting coil device, Mini-RT, has been constructed using a high temperature superconductor (HTS) for the purpose of examining a new magnetic confinement scheme of high-beta non-neutral plasmas. The floating coil is wound with silver-sheathed Bi-2223 tapes, and it is operated in the temperature range of 20-40 K. A number of studies and experiments were carried out in order to realize the necessary system. One of them was to demonstrate magnetic levitation using a miniature HTS floating coil having a diameter of 80 mm. The coil was fabricated using Bi-2223/Ag tapes of 12 m and excited by field cooling with liquid nitrogen. The magnetic levitation was examined using a real-time feedback control system with laser displacement gauges. Additionally, a persistent current switch (PCS) has been developed using Bi-2223/Ag tapes of 21 m, and a prototype HTS-PCS was tested in a cryostat. After construction of the floating coil and HTS-PCS for the Mini-RT device was completed, excitation tests were carried out in the cryostat and the basic properties up to the nominal operation condition were examined. (author)

  5. Coordinated responses of phytochelatin synthase and metallothionein genes in black mangrove, Avicennia germinans, exposed to cadmium and copper

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Mendoza, Daniel [Departamento de Recursos del Mar, Cinvestav-Unidad Merida, Merida, Yucatan (Mexico); Moreno, Adriana Quiroz [Unidad de biotecnologia, CICY, Merida, Yucatan (Mexico); Zapata-Perez, Omar [Departamento de Recursos del Mar, Cinvestav-Unidad Merida, Merida, Yucatan (Mexico)]. E-mail: ozapata@mda.cinvestav.mx

    2007-08-01

    To evaluate the role of phytochelatins and metallothioneins in heavy metal tolerance of black mangrove Avicennia germinans, 3-month-old seedlings were exposed to cadmium or copper for 30 h, under hydroponic conditions. Degenerate Mt2 and PCS primers were synthesized based on amino acid and nucleotide alignment sequences reported for Mt2 and PCS in other plant species found in GenBank. Total RNA was isolated from A. germinans leaves and two partial fragments of metallothionein and phytochelatin synthase genes were isolated. Gene expression was evaluated with reverse transcripatase-polymerase chain reaction (RT-PCR) amplification technique. Temporal analysis showed that low Cd{sup 2+} and Cu{sup 2+} concentrations caused a slight (but not significant) increase in AvMt2 expression after a 16 h exposure time, while AvPCS expression showed a significant increase under the same conditions but only after 4 h. Results strongly suggest that the rapid increase in AvPCS expression may contribute to Cd{sup 2+} and Cu{sup 2+} detoxification. Moreover, we found that A. germinans has the capacity to over-express both genes (AvMt2 and AvPCS), which may constitute a coordinated detoxification response mechanism targeting non-essential metals. Nonetheless, our results confirm that AvPCS was the most active gene involved in the regulation of essential metals (e.g., Cu{sup 2+}) in A. germinans leaves.

  6. Intelligent energy management control of vehicle air conditioning system coupled with engine

    International Nuclear Information System (INIS)

    Khayyam, Hamid; Abawajy, Jemal; Jazar, Reza N.

    2012-01-01

    Vehicle Air Conditioning (AC) systems consist of an engine powered compressor activated by an electrical clutch. The AC system imposes an extra load to the vehicle's engine increasing the vehicle fuel consumption and emissions. Energy management control of the vehicle air conditioning is a nonlinear dynamic system, influenced by uncertain disturbances. In addition, the vehicle energy management control system interacts with different complex systems, such as engine, air conditioning system, environment, and driver, to deliver fuel consumption improvements. In this paper, we describe the energy management control of vehicle AC system coupled with vehicle engine through an intelligent control design. The Intelligent Energy Management Control (IEMC) system presented in this paper includes an intelligent algorithm which uses five exterior units and three integrated fuzzy controllers to produce desirable internal temperature and air quality, improved fuel consumption, low emission, and smooth driving. The three fuzzy controllers include: (i) a fuzzy cruise controller to adapt vehicle cruise speed via prediction of the road ahead using a Look-Ahead system, (ii) a fuzzy air conditioning controller to produce desirable temperature and air quality inside vehicle cabin room via a road information system, and (iii) a fuzzy engine controller to generate the required engine torque to move the vehicle smoothly on the road. We optimised the integrated operation of the air conditioning and the engine under various driving patterns and performed three simulations. Results show that the proposed IEMC system developed based on Fuzzy Air Conditioning Controller with Look-Ahead (FAC-LA) method is a more efficient controller for vehicle air conditioning system than the previously developed Coordinated Energy Management Systems (CEMS). - Highlights: ► AC interacts: vehicle, environment, driver components, and the interrelationships between them. ► Intelligent AC algorithm which uses

  7. Digital control system of advanced reactor

    International Nuclear Information System (INIS)

    Peng Huaqing; Zhang Rui; Liu Lixin

    2001-01-01

    This article produced the Digital Control System For Advanced Reactor made by NPIC. This system uses Siemens SIMATIC PCS 7 process control system and includes five control system: reactor power control system, pressurizer level control system, pressurizer pressure control system, steam generator water level control system and dump control system. This system uses three automatic station to realize the function of five control system. Because the safety requisition of reactor is very strict, the system is redundant. The system configuration uses CFC and SCL. the human-machine interface is configured by Wincc. Finally the system passed the test of simulation by using RETRAN 02 to simulate the control object. The research solved the key technology of digital control system of reactor and will be very helpful for the nationalization of digital reactor control system

  8. Development of the operational information processing platform

    International Nuclear Information System (INIS)

    Shin, Hyun Kook; Park, Jeong Seok; Baek, Seung Min; Kim, Young Jin; Joo, Jae Yoon; Lee, Sang Mok; Jeong, Young Woo; Seo, Ho Jun; Kim, Do Youn; Lee, Tae Hoon

    1996-02-01

    The Operational Information Processing Platform(OIPP) is platform system which was designed to provide the development and operation environments for plant operation and plant monitoring. It is based on the Plant Computer Systems (PCS) of Yonggwang 3 and 4, Ulchin 3 and 4, and Yonggwang 5 and 6 Nuclear Power Plants (NPP). The UNIX based workstation, real time kernel and graphics design tool are selected and installed through the reviewing the function of PCS. In order to construct the development environment for open system architecture and distributed computer system, open computer system architecture was adapted both in hardware and software. For verification of system design and evaluation of technical methodologies, the PCS running under the OIPP is being designed and implemented. In this system, the man-machine interface and system functions are being designed and implemented to evaluate the differences between the UCN 3, 4 PCS and OIPP. 15 tabs., 32 figs., 11 refs. (Author)

  9. Clinical outcome of ovarian vein embolization in pelvic congestion ...

    African Journals Online (AJOL)

    Introduction: Pelvic congestion syndrome (PCS), is a condition associated with ovarian vein (OV) incompetence among other causes. It is manifested by chronic pelvic pain with associated dyspareunia and dysmenorrhea. The diagnosis of PCS is often overlooked and the management can be difficult. Traditional therapy for ...

  10. Availability analysis of mechanical systems with condition-based maintenance using semi-Markov and evaluation of optimal condition monitoring interval

    Science.gov (United States)

    Kumar, Girish; Jain, Vipul; Gandhi, O. P.

    2018-03-01

    Maintenance helps to extend equipment life by improving its condition and avoiding catastrophic failures. Appropriate model or mechanism is, thus, needed to quantify system availability vis-a-vis a given maintenance strategy, which will assist in decision-making for optimal utilization of maintenance resources. This paper deals with semi-Markov process (SMP) modeling for steady state availability analysis of mechanical systems that follow condition-based maintenance (CBM) and evaluation of optimal condition monitoring interval. The developed SMP model is solved using two-stage analytical approach for steady-state availability analysis of the system. Also, CBM interval is decided for maximizing system availability using Genetic Algorithm approach. The main contribution of the paper is in the form of a predictive tool for system availability that will help in deciding the optimum CBM policy. The proposed methodology is demonstrated for a centrifugal pump.

  11. Quadratic measurement and conditional state preparation in an optomechanical system

    DEFF Research Database (Denmark)

    A. Brawley, George; Vanner, Michael A.; Bowen, Warwick P.

    2014-01-01

    We experimentally demonstrate, for the first time, quadratic measurement of mechanical motion in an optomechanical system. We use this nonlinear easurement to conditionally prepare classical non-Gaussian states of motion of a micro-mechanical oscillator.......We experimentally demonstrate, for the first time, quadratic measurement of mechanical motion in an optomechanical system. We use this nonlinear easurement to conditionally prepare classical non-Gaussian states of motion of a micro-mechanical oscillator....

  12. Wire system aging assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Fantoni, P.F.; Nordlund, A.

    2006-04-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report describes a method for wire system condition monitoring, developed at the Halden Reactor Project, which is based on Frequency Domain Reflectometry. This method resulted in the development of a system called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. LIRA is composed of a signal generator, a signal analyser and a simulator that can be used to simulate several failure/degradation scenarios and assess the accuracy and sensitivity of the LIRA system. Chapter 5 of this report describes an complementary approach based on positron measurement techniques, used widely in defect physics due to the high sensitivity to micro defects, in particular open volume defects. This report describes in details these methodologies, the results of field experiments and the proposed future work. (au)

  13. Wire system aging assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. [Institutt for energiteknikk (Norway); Nordlund, A. [Chalmers Univ. of Technology (Sweden)

    2006-04-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report describes a method for wire system condition monitoring, developed at the Halden Reactor Project, which is based on Frequency Domain Reflectometry. This method resulted in the development of a system called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. LIRA is composed of a signal generator, a signal analyser and a simulator that can be used to simulate several failure/degradation scenarios and assess the accuracy and sensitivity of the LIRA system. Chapter 5 of this report describes an complementary approach based on positron measurement techniques, used widely in defect physics due to the high sensitivity to micro defects, in particular open volume defects. This report describes in details these methodologies, the results of field experiments and the proposed future work. (au)

  14. Abbreviated psychologic questionnaires are valid in patients with hand conditions

    NARCIS (Netherlands)

    Bot, Arjan G. J.; Becker, Stéphanie J. E.; van Dijk, C. Niek; Ring, David; Vranceanu, Ana-Maria

    2013-01-01

    The Pain Catastrophizing Scale (PCS) and Short Health Anxiety Inventory (SHAI) can help hand surgeons identify opportunities for psychologic support, but they are time consuming. If easier-to-use tools were available and valid, they might be widely adopted. We tested the validity of shorter versions

  15. Design of energy efficient ventilation and air-conditioning systems

    CERN Document Server

    Seppänen, Olli; Bertilsson, Thore; Maripuu, Mari-Liis; Lamy, Hervé; Vanden Borre, Alex

    2012-01-01

    This guidebook covers numerous system components of ventilation and air-conditioning systems and shows how they can be improved by applying the latest technology products. Special attention is paid to details, which are often overlooked in the daily design practice, resulting in poor performance of high quality products once they are installed in the building system.

  16. Mirasol PRT system inactivation efficacy evaluated in platelet concentrates by bacteria-contamination model

    Directory of Open Access Journals (Sweden)

    Jocić Miodrag

    2011-01-01

    Full Text Available Background/Aim. Bacterial contamination of blood components, primarily platelet concentrates (PCs, has been identified as one of the most frequent infectious complications in transfusion practice. PC units have a high risk for bacterial growth/multiplication due to their storage at ambient temperature (20 ± 2°C. Consequences of blood contamination could be effectively prevented or reduced by pathogen inactivation systems. The aim of this study was to determine the Mirasol pathogen reduction technology (PRT system efficacy in PCs using an artificial bacteria-contamination model. Methods. According to the ABO blood groups, PC units (n = 216 were pooled into 54 pools (PC-Ps. PC-Ps were divided into three equal groups, with 18 units in each, designed for an artificial bacteria-contamination. Briefly, PC-Ps were contaminated by Staphylococcus epidermidis, Staphylococcus aureus or Escherichia coli in concentrations 102 to 107 colony forming units (CFU per unit. Afterward, PC-Ps were underwent to inactivation by Mirasol PRT system, using UV (l = 265-370 nm activated riboflavin (RB. All PC-Ps were assayed by BacT/Alert Microbial Detection System for CFU quantification before and after the Mirasol treatment. Samples from non-inactivated PC-P units were tested after preparation and immediately following bacterial contamination. Samples from Mirasol treated units were quantified for CFUs one hour, 3 days and 5 days after inactivation. Results. A complete inactivation of all bacteria species was obtained at CFU concentrations of 102 and 103 per PC-P unit through storage/ investigation period. The most effective inactivation (105 CFU per PC-P unit was obtained in Escherichia coli setting. Contrary, inactivation of all the three tested bacteria species was unworkable in concentrations of ≥ 106 CFU per PC-P unit. Conclusion. Efficient inactivation of investigated bacteria types with a significant CFU depletion in PC-P units was obtained - 3 Log for all

  17. Lie and conditional symmetries of the three-component diffusive Lotka–Volterra system

    International Nuclear Information System (INIS)

    Cherniha, Roman; Davydovych, Vasyl’

    2013-01-01

    Lie and Q-conditional symmetries of the classical three-component diffusive Lotka–Volterra system in the case of one space variable are studied. The group-classification problems for finding Lie symmetries and Q-conditional symmetries of the first type are completely solved. Notably, non-Lie symmetries (Q-conditional symmetry operators) for a multi-component nonlinear reaction–diffusion system are constructed for the first time. The results are compared with those derived for the two-component diffusive Lotka–Volterra system. The conditional symmetry obtained for the non-Lie reduction of the three-component system used for modeling competition between three species in population dynamics is applied and the relevant exact solutions are found. Particularly, the exact solution describing different scenarios of competition between three species is constructed. (paper)

  18. Energy savings potential of a hybrid desiccant dehumidification air conditioning system in Beirut

    International Nuclear Information System (INIS)

    Ghali, Kamel

    2008-01-01

    In this work, the transient performance of a hybrid desiccant vapor compression air conditioning system is numerically simulated for the ambient conditions of Beirut. The main feature of this hybrid system is that the regenerative heat needed by the desiccant wheel is partly supplied by the condenser dissipated heat while the rest is supplied by an auxiliary gas heater. The hybrid air conditioning system of the present study replaces a 23 kW vapor compression unit for a typical office in Beirut characterized by a high latent load. The vapor compression subsystem size in the hybrid air conditioning system is reduced to 15 kW at the peak load when the regeneration temperature was fixed at 75 deg. C. Also the sensible heat ratio of the combined hybrid system increased from 0.47 to 0.73. Based on hour by hour simulation studies for a wide range of recorded ambient conditions of Beirut city, this paper predicts the annual energy consumption of the hybrid system in comparison with the conventional vapor compression system for the entire cooling season. The annual running costs savings for the hybrid system is 418.39 USD for a gas cost price of 0.141 USD/kg. The pay back period of the hybrid system is less than five years when the initial cost of the hybrid air conditioning system priced an additional 1712.00 USD. Hence, for a 20-year life cycle, the life cycle savings of the hybrid air conditioning system are 4295.19 USD

  19. The Use of High Performance Computing (HPC) to Strengthen the Development of Army Systems

    Science.gov (United States)

    2011-11-01

    changes in what the warfighter wants – in the middle of an acquisition cycle such changes create havoc in terms of delays, recycling of the research...A little bit later the first personal computers (PCs) came on the market, mostly as curiosities . The operating systems were either ms-dos or cp/m

  20. Operating data documentation system for a research reactor

    International Nuclear Information System (INIS)

    Kasparec, F.; Hammer, J.

    1988-01-01

    The documentation system developed for the reactor to replace the automatic data logger is described in the paper. It is based on former experiences with the data logger which had led to a selection of representative data and useful data formats, but also made clear that the paper reports produced by the hardcopy terminal were not useful for further evaluation. A special pre-buffer hardware was provided to connect the data logger to the VAX. Because of its proven reliability an Epson-HX20 microcomputer was selected for this purpose. The documentation system hardware and the software are presented. The system has been operational for about ten months, collecting a daily average of 30kByte of data, and overcome a number of VAX system crashes, maintenance days and VAX/VMS updates. Various software extensions have been developed for processing the daily reports. Among these extensions there are programs for convenient tape backup, procedures for formatted printer output, and other. It is especially helpful to use commercial personal computer software for further data processing, in particular when PCs are connected in a network with the VAX or, on the other hand, emulate VAX terminals. There is a vast number of spread-sheet or database programs with excellent computational and graphic support available for PCs. Most of them allow data import, though format conversion programs will be necessary in most of the cases

  1. Modeling and simulation for cyber-physical system security research, development and applications.

    Energy Technology Data Exchange (ETDEWEB)

    Pollock, Guylaine M.; Atkins, William Dee; Schwartz, Moses Daniel; Chavez, Adrian R.; Urrea, Jorge Mario; Pattengale, Nicholas; McDonald, Michael James; Cassidy, Regis H.; Halbgewachs, Ronald D.; Richardson, Bryan T.; Mulder, John C.

    2010-02-01

    This paper describes a new hybrid modeling and simulation architecture developed at Sandia for understanding and developing protections against and mitigations for cyber threats upon control systems. It first outlines the challenges to PCS security that can be addressed using these technologies. The paper then describes Virtual Control System Environments (VCSE) that use this approach and briefly discusses security research that Sandia has performed using VCSE. It closes with recommendations to the control systems security community for applying this valuable technology.

  2. An efficient water conditioning system for land-based abalone aquaculture

    Energy Technology Data Exchange (ETDEWEB)

    Davis, C.P. [University of Edinburgh (United Kingdom). School of GeoSciences; Carrington, C.G. [University of Otago, Dunedin (New Zealand). Dept. of Physics

    2005-07-01

    Data collected from a single grow-out tank in an abalone farm in southern New Zealand has highlighted hygiene maintenance problems in the use of semi-closed water conditioning systems for the aquaculture of New Zealand black foot abalone Haliotis iris. The data shows that semi-closed systems can have high concentrations of un-ionized ammonia, which is harmful to the animals. In this paper an alternative open flow-through system is suggested where energy demand is limited by heat recovery at the grow-out tank outlet. Using temperature data collected over 1 year, and a previously obtained expression for standing losses, a simple energy model is presented for an open system with heat recovery. To compliment the energy model, a function has been established for abalone production with respect to the concentration of un-ionized ammonia and water temperature. The energy model and production function are combined to determine the impact of plant design and tank conditions on the economics of the operation for the southern New Zealand climate. It is demonstrated that temperature control is financially preferable to an open system with no temperature control, and estimates of optimum operating conditions are given. (author)

  3. Expert system based radionuclide identification

    International Nuclear Information System (INIS)

    Aarnio, P.A.; Ala-Heikkil, J.J.; Hakulinen, T.T.; Nikkinen, M.T.

    1998-01-01

    An expert system coupled with the gamma spectrum analysis system SAMPO has been developed for automating the qualitative identification of radionuclides as well as for determining the quantitative parameters of the spectrum components. The program is written in C-language and runs in various environments ranging from PCs to UNIX workstations. The expert system utilizes a complete gamma library with over 2600 nuclides and 80,000 lines, and a rule base of about fifty criteria including energies, relative peak intensities, genesis modes, half lives, parent-daughter relationships, etc. The rule base is furthermore extensible by the user. This is not an original contribution but a somewhat updated version of papers and reports previously published elsewhere. (author)

  4. Prioritization Assessment for Capability Gaps in Weapon System of Systems Based on the Conditional Evidential Network

    Directory of Open Access Journals (Sweden)

    Dong Pei

    2018-02-01

    Full Text Available The prioritization of capability gaps for weapon system of systems is the basis for design and capability planning in the system of systems development process. In order to address input information uncertainties, the prioritization of capability gaps is computed in two steps using the conditional evidential network method. First, we evaluated the belief distribution of degree of required satisfaction for capabilities, and then calculated the reverse conditional belief function between capability hierarchies. We also provided verification for the feasibility and effectiveness of the proposed method through a prioritization of capability gaps calculation using an example of a spatial-navigation-and-positioning system of systems.

  5. A modern diagnostic approach for automobile systems condition monitoring

    Science.gov (United States)

    Selig, M.; Shi, Z.; Ball, A.; Schmidt, K.

    2012-05-01

    An important topic in automotive research and development is the area of active and passive safety systems. In general, it is grouped in active safety systems to prevent accidents and passive systems to reduce the impact of a crash. An example for an active system is ABS while a seat belt tensioner represents the group of passive systems. Current developments in the automotive industry try to link active with passive system components to enable a complete event sequence, beginning with the warning of the driver about a critical situation till the automatic emergency call after an accident. The cross-linking has an impact on the current diagnostic approach, which is described in this paper. Therefore, this contribution introduces a new diagnostic approach for automotive mechatronic systems. The concept is based on monitoring the messages which are exchanged via the automotive communication systems, e.g. the CAN bus. According to the authors' assumption, the messages on the bus are changing between faultless and faulty vehicle condition. The transmitted messages of the sensors and control units are different depending on the condition of the car. First experiments are carried and in addition, the hardware design of a suitable diagnostic interface is presented. Finally, first results will be presented and discussed.

  6. A modern diagnostic approach for automobile systems condition monitoring

    International Nuclear Information System (INIS)

    Selig, M; Ball, A; Shi, Z; Schmidt, K

    2012-01-01

    An important topic in automotive research and development is the area of active and passive safety systems. In general, it is grouped in active safety systems to prevent accidents and passive systems to reduce the impact of a crash. An example for an active system is ABS while a seat belt tensioner represents the group of passive systems. Current developments in the automotive industry try to link active with passive system components to enable a complete event sequence, beginning with the warning of the driver about a critical situation till the automatic emergency call after an accident. The cross-linking has an impact on the current diagnostic approach, which is described in this paper. Therefore, this contribution introduces a new diagnostic approach for automotive mechatronic systems. The concept is based on monitoring the messages which are exchanged via the automotive communication systems, e.g. the CAN bus. According to the authors' assumption, the messages on the bus are changing between faultless and faulty vehicle condition. The transmitted messages of the sensors and control units are different depending on the condition of the car. First experiments are carried and in addition, the hardware design of a suitable diagnostic interface is presented. Finally, first results will be presented and discussed.

  7. From the conceptual design to the first simulation of the new WEST plasma control system

    Energy Technology Data Exchange (ETDEWEB)

    Nouailletas, R., E-mail: remy.nouailletas@cea.fr [IRFM, CEA, F-13108 Saint Paul lez Durance (France); Ravenel, N.; Signoret, J. [IRFM, CEA, F-13108 Saint Paul lez Durance (France); Treutterer, W. [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Spring, A.; Lewerentz, M. [Max Planck Institute for Plasma Physics, Wendeksteinstr. 1, 17491 Greifswald (Germany); Rapson, C.J. [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Masand, H.; Dhongde, J. [Institute for Plasma Research (IPR), Near Indira Bridge, Bhat, Gandhinagar 382 428, Gujarat (India); Moreau, P.; Guillerminet, B.; Brémond, S.; Allegretti, L. [IRFM, CEA, F-13108 Saint Paul lez Durance (France); Raupp, G. [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Werner, A. [Max Planck Institute for Plasma Physics, Wendeksteinstr. 1, 17491 Greifswald (Germany); Saint Laurent, F.; Nardon, E. [IRFM, CEA, F-13108 Saint Paul lez Durance (France); Bhandarkar, M. [Institute for Plasma Research (IPR), Near Indira Bridge, Bhat, Gandhinagar 382 428, Gujarat (India)

    2015-10-15

    Highlights: • We propose an overview of the future control system of the Tore Supra in WEST configuration. • The control system will be based on DCS (Discharge Control System) of ASDEX Upgrade. • The Pulse Schedule Editor will be based on the experiment program editor of the future W7X facility. • The operation of this new system is illustrated by an example based on a simple plasma current/loop voltage control. - Abstract: The configuration of the Tore Supra WEST project leads to control challenges and event handling close to those of ITER from a plasma scenario point of view (X-point configuration, H mode, long duration pulse) and from a machine protection point of view (metallic environment). Based on previous conceptual studies and to meet the WEST requirements, a sub-project will implement a new plasma control system (PCS) and a new pulse schedule editor (PSE). The main idea is to use a segment approach to describe the pulse scheduling with a full integration of event handling both on the PCS and on the PSE. After detailed specification work, it has been shown that the real-time framework called DCS (Discharge Control System) which is currently used on ASDEX upgrade fulfills the requirements and could be integrated into the WEST global control infrastructure. For the PSE, the Xedit tool, developed for the future W7X facility, has been chosen. This contribution will begin by a short explanation of the concepts proposed for the control of the plasma and the handling of events during the plasma discharge. Then it will focus on the new centralized architecture of the new Tore Supra PCS and an operating principle example showing the efficiency of the approach to handle normal and off-normal events. This later point will illustrate the required modifications of DCS and Xedit to fit with the Tore Supra Control infrastructure.

  8. Response of Simple, Model Systems to Extreme Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ewing, Rodney C. [Univ. of Michigan, Ann Arbor, MI (United States); Lang, Maik [Univ. of Michigan, Ann Arbor, MI (United States)

    2015-07-30

    The focus of the research was on the application of high-pressure/high-temperature techniques, together with intense energetic ion beams, to the study of the behavior of simple oxide systems (e.g., SiO2, GeO2, CeO2, TiO2, HfO2, SnO2, ZnO and ZrO2) under extreme conditions. These simple stoichiometries provide unique model systems for the analysis of structural responses to pressure up to and above 1 Mbar, temperatures of up to several thousands of kelvin, and the extreme energy density generated by energetic heavy ions (tens of keV/atom). The investigations included systematic studies of radiation- and pressure-induced amorphization of high P-T polymorphs. By studying the response of simple stoichiometries that have multiple structural “outcomes”, we have established the basic knowledge required for the prediction of the response of more complex structures to extreme conditions. We especially focused on the amorphous state and characterized the different non-crystalline structure-types that result from the interplay of radiation and pressure. For such experiments, we made use of recent technological developments, such as the perforated diamond-anvil cell and in situ investigation using synchrotron x-ray sources. We have been particularly interested in using extreme pressures to alter the electronic structure of a solid prior to irradiation. We expected that the effects of modified band structure would be evident in the track structure and morphology, information which is much needed to describe theoretically the fundamental physics of track-formation. Finally, we investigated the behavior of different simple-oxide, composite nanomaterials (e.g., uncoated nanoparticles vs. core/shell systems) under coupled, extreme conditions. This provided insight into surface and boundary effects on phase stability under extreme conditions.

  9. Fault tolerance of the NIF power conditioning system

    International Nuclear Information System (INIS)

    Larson, D.W.; Anderson, R.; Boyes, J.

    1995-01-01

    The tolerance of the circuit topology proposed for the National Ignition Facility (NIF) power conditioning system to specific fault conditions is investigated. A new pulsed power circuit is proposed for the NIF which is simpler and less expensive than previous ICF systems. The inherent fault modes of the new circuit are different from the conventional approach, and must be understood to ensure adequate NIF system reliability. A test-bed which simulates the NIF capacitor module design was constructed to study the circuit design. Measurements from test-bed experiments with induced faults are compared with results from a detailed circuit model. The model is validated by the measurements and used to predict the behavior of the actual NIF module during faults. The model can be used to optimize fault tolerance of the NIF module through an appropriate distribution of circuit inductance and resistance. The experimental and modeling results are presented, and fault performance is compared with the ratings of pulsed power components. Areas are identified which require additional investigation

  10. LHCb Conditions Database Operation Assistance Systems

    CERN Multimedia

    Shapoval, Illya

    2012-01-01

    The Conditions Database of the LHCb experiment (CondDB) provides versioned, time dependent geometry and conditions data for all LHCb data processing applications (simulation, high level trigger, reconstruction, analysis) in a heterogeneous computing environment ranging from user laptops to the HLT farm and the Grid. These different use cases impose front-end support for multiple database technologies (Oracle and SQLite are used). Sophisticated distribution tools are required to ensure timely and robust delivery of updates to all environments. The content of the database has to be managed to ensure that updates are internally consistent and externally compatible with multiple versions of the physics application software. In this paper we describe three systems that we have developed to address these issues: - an extension to the automatic content validation done by the “Oracle Streams” replication technology, to trap cases when the replication was unsuccessful; - an automated distribution process for the S...

  11. Stochastic simulations of conditional states of partially observed systems, quantum and classical

    International Nuclear Information System (INIS)

    Gambetta, Jay; Wiseman, H M

    2005-01-01

    In a partially observed quantum or classical system the information that we cannot access results in our description of the system becoming mixed, even if we have perfect initial knowledge. That is, if the system is quantum the conditional state will be given by a state matrix ρ r (t), and if classical, the conditional state will be given by a probability distribution P r (x,t), where r is the result of the measurement. Thus to determine the evolution of this conditional state, under continuous-in-time monitoring, requires a numerically expensive calculation. In this paper we demonstrate a numerical technique based on linear measurement theory that allows us to determine the conditional state using only pure states. That is, our technique reduces the problem size by a factor of N, the number of basis states for the system. Furthermore we show that our method can be applied to joint classical and quantum systems such as arise in modelling realistic (finite bandwidth, noisy) measurement

  12. Load Distribution of Semi-Central Evaporative Cooling Air-Conditioning System Based on the TRNSYS Platform

    Directory of Open Access Journals (Sweden)

    Ji Li

    2018-05-01

    Full Text Available Evaporative cooling is a green, energy-efficient cooling technology adopted in hot and dry regions, which has wider application in the field of air-conditioning systems. Outdoor meteorological parameters have a great influence on the operation mode and control strategy of evaporative cooling air-conditioning systems, and the system load distribution and system configuration will be affected. This paper aims at investigating the load distribution of semi-central evaporative cooling air-conditioning systems under the condition of hourly outdoor meteorological parameters. Firstly, this paper introduced the design partition, operation mode, controlling strategy and load distribution method on semi-central evaporative cooling air-conditioning system. Then, taking an office building in Lanzhou (China as an example, the evaporative cooling air-conditioning system was divided into five regions and the load distribution was simulated by TRNSYS (The Transient Energy System Simulation Tool under the condition of hourly outdoor meteorological parameters. Finally, the results have shown that the evaporative cooling air-conditioning system can provide 25.46% of the building loads, which was of great significance to reduce the energy consumption of air-conditioning system.

  13. Influence of changes in initial conditions for the simulation of dynamic systems

    Energy Technology Data Exchange (ETDEWEB)

    Kotyrba, Martin [Department of Informatics and Computers, University of Ostrava, 30 dubna 22, Ostrava (Czech Republic)

    2015-03-10

    Chaos theory is a field of study in mathematics, with applications in several disciplines including meteorology, sociology, physics, engineering, economics, biology, and philosophy. Chaos theory studies the behavior of dynamical systems that are highly sensitive to initial conditions—a paradigm popularly referred to as the butterfly effect. Small differences in initial conditions field widely diverging outcomes for such dynamical systems, rendering long-term prediction impossible in general. This happens even though these systems are deterministic, meaning that their future behavior is fully determined by their initial conditions, with no random elements involved. In this paperinfluence of changes in initial conditions will be presented for the simulation of Lorenz system.

  14. Performance evaluation of an integrated automotive air conditioning and heat pump system

    International Nuclear Information System (INIS)

    Hosoz, M.; Direk, M.

    2006-01-01

    This study deals with the performance characteristics of an R134a automotive air conditioning system capable of operating as an air-to-air heat pump using ambient air as a heat source. For this aim, an experimental analysis has been performed on a plant made up of original components from an automobile air conditioning system and some extra equipment employed to operate the system in the reverse direction. The system has been tested in the air conditioning and heat pump modes by varying the compressor speed and air temperatures at the inlets of the indoor and outdoor coils. Evaluation of the data gathered in steady state test runs has shown the effects of the operating conditions on the capacity, coefficient of performance, compressor discharge temperature and the rate of exergy destroyed by each component of the system for both operation modes. It has been observed that the heat pump operation provides adequate heating only in mild weather conditions, and the heating capacity drops sharply with decreasing outdoor temperature. However, compared with the air conditioning operation, the heat pump operation usually yields a higher coefficient of performance and a lower rate of exergy destruction per unit capacity. It is also possible to improve the heating mode performance of the system by redesigning the indoor coil, using another refrigerant with a higher heat rejection rate in the condenser and employing a better heat source such as the engine coolant or exhaust gases

  15. Federal Emergency Management Information System (FEMIS) Data Management Guide for FEMIS Version 1.4.6

    Energy Technology Data Exchange (ETDEWEB)

    Angel, L.K.; Bower, J.C.; Burnett, R.A.; Downing, T.R.; Fangman, P.M.; Hoza, M.; Johnson, D.M.; Johnson, S.M.; Loveall, R.M.; Millard, W.D.; Schulze, S.A.; Wood, B.M.

    1999-06-29

    The Federal Emergency Management Information System (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the U.S. Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are corrected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication data distribution and notification functionality necessary to operate FEMIS in a networked, client/server environment.

  16. Hybrid centralized-distributed power conditioning system for thermoelectric generator with high energy efficiency

    DEFF Research Database (Denmark)

    Wu, Hongfei; Sun, Kai; Chen, Min

    2013-01-01

    the proposed system, which benefits for implementing high MPPT efficiency and high conversion efficiency simultaneously. A hybrid MPPT control strategy is proposed for this HCD power conditioning system. The characteristics, circuit implementation and operation principles of the proposed system are presented......-distributed (HCD) power conditioning system for TEG and its control strategy are proposed in this paper. The HCD power conditioning system is composed by a centralized power conversion stage and multiple distributed power conversion stages. Most of the power is processed by the centralized power conversion stage...

  17. Physical disability contributes to caregiver stress in dementia caregivers.

    Science.gov (United States)

    Bruce, David G; Paley, Glenys A; Nichols, Pamela; Roberts, David; Underwood, Peter J; Schaper, Frank

    2005-03-01

    Previous findings of studies on the impact of physical illness on caregiver health have been inconsistent. The authors wanted to determine whether physical disability, as determined by the SF-12 survey that provides information on both physical and mental health problems, contributes to caregiver stress. The authors interviewed 91 primary caregivers (aged 38-85 years) of persons with dementia who had been referred by their family physicians for the first time for formal support services or memory evaluation. Caregivers completed the SF-12 version of the Medical Outcomes Study Short Form Health Survey that generates Mental Component Summary (MCS) and Physical Component Summary (PCS) scores and reported on caregiver stress and concurrent medical conditions and medications. Most caregivers reported stress (76.9%), having medical conditions (72.4%), or taking medications (67%). The MCS but not the PCS scores were significantly lower than community norms, indicating an excess of disability due to mental health problems. Nevertheless, 40.7% had PCS scores indicating some degree of physical disability. Using multiple logistic regression analysis, PCS scores but not the presence of medical problems were independently associated with caregiver stress. Chronic disability as assessed by SF-12 PCS scores is independently associated with caregiver stress. These data suggest that caregivers of persons with dementia should be assessed for disabling physical conditions and mental health problems. In addition, reducing the impact of physical disability could ameliorate caregiver stress.

  18. Experimental Study on Intelligent Control Scheme for Fan Coil Air-Conditioning System

    Directory of Open Access Journals (Sweden)

    Yanfeng Li

    2013-01-01

    Full Text Available An intelligent control scheme for fan coil air-conditioning systems has been put forward in order to overcome the shortcomings of the traditional proportion-integral-derivative (PID control scheme. These shortcomings include the inability of anti-interference and large inertia. An intelligent control test rig of fan coil air-conditioning system has been built, and MATLAB/Simulink dynamics simulation software has been adopted to implement the intelligent control scheme. A software for data exchange has been developed to combine the intelligence control system and the building automation (BA system. Experimental tests have been conducted to investigate the effectiveness of different control schemes including the traditional PID control, fuzzy control, and fuzzy-PID control for fan coil air-conditioning system. The effects of control schemes have been compared and analyzed in robustness, static and dynamic character, and economy. The results have shown that the developed data exchange interface software can induce the intelligent control scheme of the BA system more effectively. Among the proposed control strategies, fuzzy-PID control scheme which has the advantages of both traditional PID and fuzzy schemes is the optimal control scheme for the fan coil air-conditioning system.

  19. Two-Stage Battery Energy Storage System (BESS in AC Microgrids with Balanced State-of-Charge and Guaranteed Small-Signal Stability

    Directory of Open Access Journals (Sweden)

    Bing Xie

    2018-02-01

    Full Text Available In this paper, a two-stage battery energy storage system (BESS is implemented to enhance the operation condition of conventional battery storage systems in a microgrid. Particularly, the designed BESS is composed of two stages, i.e., Stage I: integration of dispersed energy storage units (ESUs using parallel DC/DC converters, and Stage II: aggregated ESUs in grid-connected operation. Different from a conventional BESS consisting of a battery management system (BMS and power conditioning system (PCS, the developed two-stage architecture enables additional operation and control flexibility in balancing the state-of-charge (SoC of each ESU and ensures the guaranteed small-signal stability, especially in extremely weak grid conditions. The above benefits are achieved by separating the control functions between the two stages. In Stage I, a localized power sharing scheme based on the SoC of each particular ESU is developed to manage the SoC and avoid over-charge or over-discharge issues; on the other hand, in Stage II, an additional virtual impedance loop is implemented in the grid-interactive DC/AC inverters to enhance the stability margin with multiple parallel-connected inverters integrating at the point of common coupling (PCC simultaneously. A simulation model based on MATLAB/Simulink is established, and simulation results verify the effectiveness of the proposed BESS architecture and the corresponding control diagram.

  20. The Conditional Entropy Power Inequality for Bosonic Quantum Systems

    Science.gov (United States)

    De Palma, Giacomo; Trevisan, Dario

    2018-06-01

    We prove the conditional Entropy Power Inequality for Gaussian quantum systems. This fundamental inequality determines the minimum quantum conditional von Neumann entropy of the output of the beam-splitter or of the squeezing among all the input states where the two inputs are conditionally independent given the memory and have given quantum conditional entropies. We also prove that, for any couple of values of the quantum conditional entropies of the two inputs, the minimum of the quantum conditional entropy of the output given by the conditional Entropy Power Inequality is asymptotically achieved by a suitable sequence of quantum Gaussian input states. Our proof of the conditional Entropy Power Inequality is based on a new Stam inequality for the quantum conditional Fisher information and on the determination of the universal asymptotic behaviour of the quantum conditional entropy under the heat semigroup evolution. The beam-splitter and the squeezing are the central elements of quantum optics, and can model the attenuation, the amplification and the noise of electromagnetic signals. This conditional Entropy Power Inequality will have a strong impact in quantum information and quantum cryptography. Among its many possible applications there is the proof of a new uncertainty relation for the conditional Wehrl entropy.

  1. Reliability analysis of emergency decay heat removal system of nuclear ship under various accident conditions

    International Nuclear Information System (INIS)

    Matsuoka, Takeshi

    1984-01-01

    A reliability analysis is given for the emergency decay heat removal system of the Nuclear Ship ''Mutsu'' and the emergency sea water cooling system of the Nuclear Ship ''Savannah'', under ten typical nuclear ship accident conditions. Basic event probabilities under these accident conditions are estimated from literature survey. These systems of Mutsu and Savannah have almost the same reliability under the normal condition. The dispersive arrangement of a system is useful to prevent the reduction of the system reliability under the condition of an accident restricted in one room. As for the reliability of these two systems under various accident conditions, it is seen that the configuration and the environmental condition of a system are two main factors which determine the reliability of the system. Furthermore, it was found that, for the evaluation of the effectiveness of safety system of a nuclear ship, it is necessary to evaluate its reliability under various accident conditions. (author)

  2. Does the air condition system in busses spread allergic fungi into driver space?

    Science.gov (United States)

    Sowiak, Małgorzata; Kozajda, Anna; Jeżak, Karolina; Szadkowska-Stańczyk, Irena

    2018-02-01

    The aim of this study was to establish whether the air-conditioning system in buses constitutes an additional source of indoor air contamination with fungi, and whether or not the fungi concentration depends on the period from the last disinfection of the system, combined with replacement of the cabin dust particle filter. The air samples to fungi analysis using impact method were taken in 30 buses (20 with an air-conditioning system, ACS; 10 with a ventilation system, VS) in two series: 1 and 22 weeks after cabin filter replacement and disinfection of the air-conditioning system. During one test in each bus were taken two samples: before the air-conditioning or ventilation system switched on and 6 min after operating of these systems. The atmospheric air was the external background (EB). After 1 week of use of the system, the fungi concentrations before starting of the ACS and VS system were 527.8 and 1053.0 cfu/m 3 , respectively, and after 22 weeks the concentrations were 351.9 and 1069.6 cfu/m 3 , respectively. While in the sample after 6 min of ACS and VS system operating, the fungi concentration after 1 week of use was 127.6 and 233.7 cfu/m 3 , respectively, and after 22 weeks it was 113.3 and 324.9 cfu/m 3 , respectively. Results do not provide strong evidence that air-conditioning system is an additional source of indoor air contamination with fungi. A longer operation of the system promoted increase of fungi concentration in air-conditioned buses only.

  3. New oil condition monitoring system, Wearsens® enables continuous, online detection of critical operating conditions and wear damage

    Directory of Open Access Journals (Sweden)

    Manfred Mauntz

    2015-12-01

    Full Text Available A new oil sensor system is presented for the continuous, online measurement of the wear in turbines, industrial gears, generators, hydraulic systems and transformers. Detection of change is much earlier than existing technologies such as particle counting, vibration measurement or recording temperature. Thus targeted, corrective procedures and/or maintenance can be carried out before actual damage occurs. Efficient machine utilization, accurately timed preventive maintenance, increased service life and a reduction of downtime can all be achieved. The presented sensor system effectively controls the proper operation conditions of bearings and cogwheels in gears. The online diagnostics system measures components of the specific complex impedance of oils. For instance, metal abrasion due to wear debris, broken oil molecules, forming acids or oil soaps, result in an increase of the electrical conductivity, which directly correlates with the degree of contamination of the oil. For additivated lubricants, the stage of degradation of the additives can also be derived from changes in the dielectric constant. The determination of impurities or reduction in the quality of the oil and the quasi continuous evaluation of wear and chemical aging follow the holistic approach of a real-time monitoring of an alteration in the condition of the oil-machine system. Once the oil condition monitoring sensors are installed on the wind turbine, industrial gearbox and test stands, the measuring data can be displayed and evaluated elsewhere. The signals are transmitted to a web-based condition monitoring system via LAN, WLAN or serial interfaces of the sensor unit. Monitoring of the damage mechanisms during proper operation below the tolerance limits of the components enables specific preventive maintenance independent of rigid inspection intervals.

  4. An equivalent condition for stability properties of Lotka-Volterra systems

    International Nuclear Information System (INIS)

    Chu Tianguang

    2007-01-01

    We give a solvable Lie algebraic condition for the equivalence of four typical stability notions (asymptotic stability, D-stability, total stability, and Volterra-Lyapunov stability) concerning Lotka-Volterra systems. Our approach makes use of the decomposition of the interaction matrix into symmetric and skew-symmetric parts, which may be related to the cooperative and competitive interaction pattern of a Lotka-Volterra system. The present result covers a known condition and can yield a larger set of interaction matrices for equivalence of the stability properties

  5. Sex differences in the stability of conditioned pain modulation (CPM) among patients with chronic pain.

    Science.gov (United States)

    Martel, Marc O; Wasan, Ajay D; Edwards, Robert R

    2013-11-01

    To examine the temporal stability of conditioned pain modulation (CPM), formerly termed diffuse noxious inhibitory controls, among a sample of patients with chronic pain. The study also examined the factors that might be responsible for the stability of CPM. In this test-retest study, patients underwent a series of standardized psychophysical pain-testing procedures designed to assess CPM on two separate occasions (i.e., baseline and follow up). Patients also completed self-report measures of catastrophizing (Pain Catastrophizing Scale [PCS] and negative affect [NA]). Overall, results provided evidence for the stability of CPM among patients with chronic pain. Results, however, revealed considerable sex differences in the stability of CPM. For women, results revealed a significant test-retest correlation between baseline and follow-up CPM scores. For men, however, the test-retest correlation between baseline and follow-up CPM scores was not significant. Results of a Fisher's Z-test revealed that the stability of CPM was significantly greater for women than for men. Follow-up analyses revealed that the difference between men and women in the stability of CPM could not be accounted for by any demographic (e.g., age) and/or psychological factors (PCS and NA). Our findings suggest that CPM paradigms possess sufficient reliability to be incorporated into bedside clinical evaluation of patients with chronic pain, but only among women. The lack of CPM reproducibility/stability observed among men places limits on the potential use of CPM paradigms in clinical settings for the assessment of men's endogenous pain-inhibitory function. Wiley Periodicals, Inc.

  6. Development of Fuzzy Logic Control for Vehicle Air Conditioning System

    Directory of Open Access Journals (Sweden)

    Henry Nasution

    2008-08-01

    Full Text Available A vehicle air conditioning system is experimentally investigated. Measurements were taken during the experimental period at a time interval of one minute for a set point temperature of 22, 23 and 24oC with internal heat loads of 0, 1 and 2 kW. The cabin temperature and the speed of the compressor were varied and the performance of the system, energy consumption and energy saving ware analyzed. The main objective of the experimental work is to evaluate the energy saving obtained when the fuzzy logic control (FLC algorithm, through an inverter, continuously regulates the compressor speed. It demonstrates better control of the compressor operation in terms of energy consumption as compared to the control by using a thermostat imposing On/Off cycles on the compressor at the nominal frequency of 50 Hz. The experimental set-up consists of original components from the air conditioning system of a compact passenger vehicle. The experimental results indicate that the proposed technique can save energy and improve indoor comfort significantly for vehicle air conditioning systems compared to the conventional (On/Off control technique.

  7. Rapid Conditioning for the Next Generation Melting System

    Energy Technology Data Exchange (ETDEWEB)

    Rue, David M. [Gas Technology Institute, Des Plaines, IL (United States)

    2015-06-17

    This report describes work on Rapid Conditioning for the Next Generation Melting System under US Department of Energy Contract DE-FC36-06GO16010. The project lead was the Gas Technology Institute (GTI). Partners included Owens Corning and Johns Manville. Cost share for this project was provided by NYSERDA (the New York State Energy Research and Development Authority), Owens Corning, Johns Manville, Owens Illinois, and the US natural gas industry through GTI’s SMP and UTD programs. The overreaching focus of this project was to study and develop rapid refining approaches for segmented glass manufacturing processes using high-intensity melters such as the submerged combustion melter. The objectives of this project were to 1) test and evaluate the most promising approaches to rapidly condition the homogeneous glass produced from the submerged combustion melter, and 2) to design a pilot-scale NGMS system for fiberglass recycle.

  8. Operating conditions of batteries in off-grid renewable energy systems

    DEFF Research Database (Denmark)

    Svoboda, V.; Wenzl, H.; Kaiser, R.

    2007-01-01

    for batteries. Categories are defined in such a way that batteries belonging to the same category are subjected to similar operating conditions and a similar combination of stress factors. The results provide a comprehensive overview of battery operating conditions in existing off-grid renewable energy systems...

  9. Interleukin-17 Promotes Neutrophil-Mediated Immunity by Activating Microvascular Pericytes and Not Endothelium

    Science.gov (United States)

    Liu, Rebecca; Lauridsen, Holly M.; Amezquita, Robert A.; Pierce, Richard W.; Jane-wit, Dan; Fang, Caodi; Pellowe, Amanda S.; Kirkiles-Smith, Nancy C.; Gonzalez, Anjelica L.; Pober, Jordan S.

    2016-01-01

    A classical hallmark of acute inflammation is neutrophil infiltration of tissues, a multi-step process that involves sequential cell-cell interactions of circulating leukocytes with interleukin (IL)-1- or tumor necrosis factor-α (TNF)-activated microvascular endothelial cells (ECs) and pericytes (PCs) that form the wall of the postcapillary venules. The initial infiltrating cells accumulate perivascularly in close proximity to PCs. IL-17, a pro-inflammatory cytokine that acts on target cells via a heterodimeric receptor formed by IL-17RA and IL-17RC subunits, also promotes neutrophilic inflammation but its effects on vascular cells are less clear. We report that both cultured human ECs and PCs strongly express IL-17RC and, while neither cell type expresses much IL-17RA, PCs express significantly more than ECs. IL-17, alone or synergistically with TNF, significantly alters inflammatory gene expression in cultured human PCs but not ECs. RNA-seq analysis identifies many IL-17-induced transcripts in PCs encoding proteins known to stimulate neutrophil-mediated immunity. Conditioned media (CM) from IL-17-activated PCs, but not ECs, induce pertussis toxin-sensitive neutrophil polarization, likely mediated by PC-secreted chemokines, and also stimulate neutrophil production of pro-inflammatory molecules, including TNF, IL-1α, IL-1β, and IL-8. Furthermore, IL-17-activated PCs but not ECs can prolong neutrophil survival by producing G-CSF and GM-CSF, delaying the mitochondria outer membrane permeabilization and caspase 9 activation. Importantly, neutrophils exhibit enhanced phagocytic capacity after activation by CM from IL-17-treated PCs. We conclude that PCs, not ECs, are the major target of IL-17 within the microvessel wall and that IL-17-activated PCs can modulate neutrophil functions within the perivascular tissue space. PMID:27534549

  10. Continuous mercury monitors conditioning/conversion systems : what we have learned

    Energy Technology Data Exchange (ETDEWEB)

    Laudal, D.L.; Dunham, G.E.; Thompson, J.S. [North Dakota Univ., Grand Forks, ND (United States). Energy and Environmental Research Center

    2006-07-01

    The challenges of continuous mercury monitoring (CMM) in flue gas were discussed with reference to conditioning/conversion systems where a sample of gas of an unknown composition is conditioned to elemental mercury. Flue gas composition varies greatly depending on coal type and plant configuration. The widely used wet-chemistry systems remove interfering gas constituents by bubbling the sample gas through reactive solutions. Some concerns with the wet systems are the amount of chemicals used and the volume of the waste generated; capture of CO{sub 2} which affects the sample volume; mercury hang-up; condensation of flue gas constituents; and, potential for unidentified chemical reactions. The advantages of dry systems were discussed, such as the ability to convert all of the mercury present in the flue gas to elemental mercury. Some of the main concerns with dry systems are that some systems will require a correction for moisture, which means installing a moisture monitor. Dry systems can also be prone to mercury hang-up and calibration of some of the dilution systems remains a concern. The systems can also be susceptible a significant decrease in catalyst life. figs.

  11. Control system for BARC-TIFR Pelletron

    International Nuclear Information System (INIS)

    Singh, S.; Singh, P.; Gore, J.; Kulkarni, S.

    2012-01-01

    BARC-TIFR Pelletron is a 14 MV tandem accelerator in operation from more than 20 years. It was having a DOS based control system software which was running on a 486 PC and it was not possible to port it on new PCs. It was based on serial highway and Uport adapter based CAMAC crate controller which are now not available and all spares were used. Hence we have changed CAMAC controller with in house developed Ethernet based CAMAC controller and new software has been developed. New Control system software is based on LINUX operating system with graphical user interface developed using Trolltech's QT API, but can be easily ported on MS windows. (author)

  12. Comparison of desiccant air conditioning systems with different indirect evaporative air coolers

    International Nuclear Information System (INIS)

    Pandelidis, Demis; Anisimov, Sergey; Worek, William M.; Drąg, Paweł

    2016-01-01

    Highlights: • A numerical study of desiccant air conditioning systems is presented. • The ε-NTU model is used for the analysis. • Different arrangements of the desiccant systems were compared. • The systems were compared under different operating conditions. - Abstract: This paper presents a numerical analysis of three desiccant air-conditioning systems equipped with different indirect evaporative air coolers: (1) the cross-flow Maisotsenko cycle heat and mass exchanger (HMX), (2) the regenerative counter-flow Maisotsenko cycle heat and mass exchanger and (3) the standard cross-flow evaporative air cooler. To analyze the desiccant wheel and the indirect evaporative air coolers, the modified ε-NTU-model was used. The simulations were performed under assumption that the desiccant wheel is regenerated with air heated to relatively low temperature values (50–60 °C), which can be produced with solar panels in typical moderate climatic conditions. It was established that the main advantage of the presented solutions is that they can provide comfort conditions even with less effective dehumidification. The different systems were compared under variable selected operational factors (i.e. inlet air temperature, humidity and regeneration air temperature). The analysis allowed establishing the advantages and disadvantages of presented solutions and allowed estimating their application potential.

  13. [Microbial air purity in hospitals. Operating theatres with air conditioning system].

    Science.gov (United States)

    Krogulski, Adam; Szczotko, Maciej

    2010-01-01

    The aim of this study was to show the influence of air conditioning control for microbial contamination of air inside the operating theatres equipped with correctly working air-conditioning system. This work was based on the results of bacteria and fungi concentration in hospital air obtained since 2001. Assays of microbial air purity conducted on atmospheric air in parallel with indoor air demonstrated that air filters applied in air-conditioning systems worked correctly in every case. To show the problem of fluctuation of bacteria concentration more precisely, every sequences of single results from successive measure series were examined independently.

  14. Natural circulation under variable primary mass inventories at BETHSY facility

    International Nuclear Information System (INIS)

    Bazin, P.; Clement, P.; Deruaz, R.

    1989-01-01

    BETHSY is a high pressure integral test facility which models a 3 loop Framatome PWR with the intent of studying PWR accidents. The BETHSY programme includes both accident transients and tests under successive steady state conditions. So far, tests of the latter type have been especially devoted to situations where natural circulation takes place in the primary coolant system (PCS). Tests 4.1a and 4.1a TC, the results of which are introduced, deal with PCS natural circulation patterns and related heat transport mechanisms under two different core power levels (2 and 5% of nominal power), variable primary mass inventory (100% to 30-40% according to core power) and at two different steam generator liquid levels (standard value and 1 meter). (orig.)

  15. Interactive Check System for Facilitating Self-awareness of Dorm Students in Upper Secondary Education

    OpenAIRE

    Akamatsu , Shigenori; Yoshida , Masanobu; Satoh , Hironobu; Yamaguchi , Takumi

    2015-01-01

    International audience; We describe a new interactive system using a social learning platform to provide dormitory students with the ability to communicate with teachers/advisors in a timely manner to promote self-active awareness of the dormitory environment. Our system comprises tablet PCs, cloud computing services, and application and server software to enable collaboration over a high-speed wireless local area network that covers the campus, dormitory, and teachers’ homes. The purpose of ...

  16. NASA-Langley Research Center's Aircraft Condition Analysis and Management System Implementation

    Science.gov (United States)

    Frye, Mark W.; Bailey, Roger M.; Jessup, Artie D.

    2004-01-01

    This document describes the hardware implementation design and architecture of Aeronautical Radio Incorporated (ARINC)'s Aircraft Condition Analysis and Management System (ACAMS), which was developed at NASA-Langley Research Center (LaRC) for use in its Airborne Research Integrated Experiments System (ARIES) Laboratory. This activity is part of NASA's Aviation Safety Program (AvSP), the Single Aircraft Accident Prevention (SAAP) project to develop safety-enabling technologies for aircraft and airborne systems. The fundamental intent of these technologies is to allow timely intervention or remediation to improve unsafe conditions before they become life threatening.

  17. Platelet storage lesion in interim platelet unit concentrates: A comparison with buffy-coat and apheresis concentrates.

    Science.gov (United States)

    Singh, Sukhi; Shams Hakimi, Caroline; Jeppsson, Anders; Hesse, Camilla

    2017-12-01

    Platelet storage lesion is characterized by morphological changes and impaired platelet function. The collection method and storage medium may influence the magnitude of the storage lesion. The aim of this study was to compare the newly introduced interim platelet unit (IPU) platelet concentrates (PCs) (additive solution SSP+, 40% residual plasma content) with the more established buffy-coat PCs (SSP, 20% residual plasma content) and apheresis PCs (autologous plasma) in terms of platelet storage lesions. Thirty PCs (n=10 for each type) were assessed by measuring metabolic parameters (lactate, glucose, and pH), platelet activation markers, and in vitro platelet aggregability on days 1, 4, and 7 after donation. The expression of platelet activation markers CD62p (P-selectin), CD63 (LAMP-3), and phosphatidylserine was measured using flow cytometry and in vitro aggregability was measured with multiple electrode aggregometry. Higher platelet activation and lower in vitro aggregability was observed in IPU than in buffy-coat PCs on day 1 after donation. In contrast, metabolic parameters, expression of platelet activation markers, and in vitro aggregability were better maintained in IPU than in buffy-coat PCs at the end of the storage period. Compared to apheresis PCs, IPU PCs had higher expression of activation markers and lower in vitro aggregability throughout storage. In conclusion, the results indicate that there are significant differences in platelet storage lesions between IPU, buffy-coat, and apheresis PCs. The quality of IPU PCs appears to be at least comparable to buffy-coat preparations. Further studies are required to distinguish the effect of the preparation methods from storage conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Power conditioning for space nuclear reactor systems

    Science.gov (United States)

    Berman, Baruch

    1987-01-01

    This paper addresses the power conditioning subsystem for both Stirling and Brayton conversion of space nuclear reactor systems. Included are the requirements summary, trade results related to subsystem implementation, subsystem description, voltage level versus weight, efficiency and operational integrity, components selection, and shielding considerations. The discussion is supported by pertinent circuit and block diagrams. Summary conclusions and recommendations derived from the above studies are included.

  19. Safe and efficient method for cryopreservation of human induced pluripotent stem cell-derived neural stem and progenitor cells by a programmed freezer with a magnetic field.

    Science.gov (United States)

    Nishiyama, Yuichiro; Iwanami, Akio; Kohyama, Jun; Itakura, Go; Kawabata, Soya; Sugai, Keiko; Nishimura, Soraya; Kashiwagi, Rei; Yasutake, Kaori; Isoda, Miho; Matsumoto, Morio; Nakamura, Masaya; Okano, Hideyuki

    2016-06-01

    Stem cells represent a potential cellular resource in the development of regenerative medicine approaches to the treatment of pathologies in which specific cells are degenerated or damaged by genetic abnormality, disease, or injury. Securing sufficient supplies of cells suited to the demands of cell transplantation, however, remains challenging, and the establishment of safe and efficient cell banking procedures is an important goal. Cryopreservation allows the storage of stem cells for prolonged time periods while maintaining them in adequate condition for use in clinical settings. Conventional cryopreservation systems include slow-freezing and vitrification both have advantages and disadvantages in terms of cell viability and/or scalability. In the present study, we developed an advanced slow-freezing technique using a programmed freezer with a magnetic field called Cells Alive System (CAS) and examined its effectiveness on human induced pluripotent stem cell-derived neural stem/progenitor cells (hiPSC-NS/PCs). This system significantly increased cell viability after thawing and had less impact on cellular proliferation and differentiation. We further found that frozen-thawed hiPSC-NS/PCs were comparable with non-frozen ones at the transcriptome level. Given these findings, we suggest that the CAS is useful for hiPSC-NS/PCs banking for clinical uses involving neural disorders and may open new avenues for future regenerative medicine. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  20. Prevalence of chronic medical conditions among inmates in the Texas prison system.

    Science.gov (United States)

    Harzke, Amy J; Baillargeon, Jacques G; Pruitt, Sandi L; Pulvino, John S; Paar, David P; Kelley, Michael F

    2010-05-01

    Given the rapid growth and aging of the US prison population in recent years, the disease profile and health care needs of inmates portend to have far-reaching public health implications. Although numerous studies have examined infectious disease prevalence and treatment in incarcerated populations, little is known about the prevalence of non-infectious chronic medical conditions in US prison populations. The purpose of this study was to estimate the prevalence of selected non-infectious chronic medical conditions among inmates in the Texas prison system. The study population consisted of the total census of inmates who were incarcerated in the Texas Department of Criminal Justice for any duration from September 1, 2006 through August 31, 2007 (N=234,031). Information on medical diagnoses was obtained from a system-wide electronic medical record system. Overall crude prevalence estimates for the selected conditions were as follows: hypertension, 18.8%; asthma, 5.4%; diabetes, 4.2%; ischemic heart disease, 1.7%; chronic obstructive pulmonary disease, 0.96%; and cerebrovascular disease, 0.23%. Nearly one quarter (24.5%) of the study population had at least one of the selected conditions. Except for asthma, crude prevalence estimates of the selected conditions increased monotonically with age. Nearly two thirds (64.6%) of inmates who were >or=55 years of age had at least one of the selected conditions. Except for diabetes, crude prevalence estimates for the selected conditions were lower among Hispanic inmates than among non-Hispanic White inmates and African American inmates. Although age-standardized prevalence estimates for the selected conditions did not appear to exceed age-standardized estimates from the US general population, a large number of inmates were affected by one or more of these conditions. As the prison population continues to grow and to age, the burden of these conditions on correctional and community health care systems can be expected to increase.

  1. Federal Emergency Management Information System (FEMIS) data management guide, version 1.4.5

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, R.A.; Downing, T.R.; Gaustad, K.L. [and others

    1998-06-26

    The Federal Emergency Management Information System (FEMIS) information resources are described in this FEMIS Data Management Guide. To comprehend what types of data are present, where the data is located, and how it is managed during the life span of the system, a basic understanding of the FEMIS architecture is necessary. The system is being developed by Pacific Northwest National Laboratory (PNNL) and is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). The capability to connect to remote CSEPP sites and share information will be present in a future release. Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are connected via a local area network (LAN) to servers that provide efficient EOC-wide services. Each EOC is interconnected to other EOCs via telecommunications links. FEMIS is a client/server system where much of the application software is located in the client PC. This client software integrates the FEMIS application, government furnished dispersion and evacuation models, and Commercial-Off-The-Shelf (COTS) software tools such as the ArcView geographic information system (GIS) and Microsoft Project (electron planning). A UNIX server provides data management services, ARC/INFO GIS capabilities, evacuation (Evac) modeling, electron main (E-mail), and meteorological (Met) input processing. A PC communication utility is available to interface with external subsystems. At this time, the weather collection system (Handar Met System) is the only external subsystem.

  2. System for monitoring microclimate conditions in greenhouse

    Directory of Open Access Journals (Sweden)

    Marković Dušan B.

    2014-01-01

    Full Text Available Monitoring microclimate parameters in different kind of environments has significant contribution to many areas of human activity and production processes. One of them is vegetable production in greenhouses where measurement of its microclimate parameters may influence the decision on taking appropriate action and protect crops. It is also important to preserve optimal condition in greenhouses to facilitate the process of transpiration, plant mineral nutrition and prevent of a variety physiological damage caused by a deficit of some specific nutrients. Systems for monitoring have wide application in the last years thanks to development of modern computer technology. In this paper model of the monitoring system based on smart transducer concept was introduced. Within the system components are based on MSP430 ultra low power micro controllers. They are using wireless communication to exchange data within the system that was structured according to smart transducer concept. User applications from the network could access to system interface using HTTP protocol where web server could be running on the computer or it could be an embedded web server running on micro controller based device.

  3. A ORACLE-based system for data collection, storage and analysis of main equipment load factors in NPPs and TPPs

    International Nuclear Information System (INIS)

    Ivanova, L.

    1993-01-01

    This data base is developed by the National Electricity Company, Sofia (BG) as an aid to supervision, analysis and administration decision making in a variety of operational situations in NPPs and TPPs. As major indicators of the equipment condition the following primary data are stored: steam or electricity production per month; operation hours per month; equipment stand-by outages; planned outages; unplanned permitted maintenance outages; unplanned emergency maintenance outages; number of outages of the unit per month. These data cover the period from the putting of the corresponding equipment into operation till the present moment, i.e. or about 32 years. The data up to 1990 are annual and for the last three years - monthly. Based on these primary data, the following quantities are calculated: average capacity; average load factors; operation time factors - total and accounting for the planned and the permitted unplanned outages; unpermitted outages factors - total and accounting for the planned and the permitted outages. All the factors are calculated on user's request for a chosen time period, by summing up correspondingly the major indicators (production, operation hours and various outages) for the given period. The system operates on an IBM 4341 under VM/SP and DB ORACLE V.5. The input is entered directly from the TPP and NPP by telex lines from PCs, operating also as telex machines, into the mainframe of Energokibernetika Ltd. They are available to all authorised users from local terminals or PCs, connected to the computer by synchronous or asynchronous lines. A system for data transmission to remote users along commutated telephone lines is also developed. (R. Ts.)

  4. Personal computers pollute indoor air: effects on perceived air quality, SBS symptoms and productivity in offices

    DEFF Research Database (Denmark)

    Bako-Biro, Zsolt; Wargocki, Pawel; Weschler, Charles J.

    2002-01-01

    was reduced and air freshness increased; all effects were significant. In the presence of PCs the performance of text typing significantly decreased. The sensory pollution load of the PCs was found to be 3 olf per PC, i.e. three times the load of the occupants. Present results indicate negative effects of PCs......Perceived air quality and Sick Building Syndrome (SBS) symptoms were studied in a low-polluting office space ventilated at an air change rate of 2 h-1 (10 L/s per person with 6 people present) with and without personal computers (PCs). Other environmental parameters were kept constant. Thirty...... female subjects were exposed for 4.8 h to each of the two conditions in the office and performed simulated office work. They remained thermally neutral by adjusting their clothing and were blind to the interventions. In the absence of PCs in the office the perceived air quality improved, odour intensity...

  5. Thermo economical evaluation of retrofitting strategies in air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Tribess, Arlindo; Fiorelli, Flavio Augusto Sanzogo; Hernandez Neto, Alberto [Sao Paulo Univ., SP (Brazil). Escola Politecnica. Dept. de Engenharia Mecanica]. E-mail: atribess@usp.br; fiorelli@usp.br; ahneto@usp.br

    2000-07-01

    In a building project, several subsystems are designed, among them the air conditioning system. Electrical energy consumption profiles show that this subsystem is responsible for 40 to 50% of total consumption in a commercial building. Besides the study of technical aspects that should be considered in order to assure the thermal comfort of the occupants as well the temperature and humidity conditions for an efficient equipment operation, an economical evaluation of this subsystem should be also made. In retrofit projects, the economical aspect is also critical for such projects in order to assure bigger efficiency in an economically attractive way. This paper analyses some strategies that might be adopted in retrofitting an air conditioning system installed in a commercial building with mixed occupation. By mixed we mean that some floors have a typical office occupation profile and other floors are mainly occupied by electronic equipment. This analysis includes both technical and economical evaluation. The proposed solutions performance are compared to the old system, which allows to verify the retrofitting impact in energy consumption reduction and its economical feasibility. (author)

  6. DESIGN OF WATER-COOLED PACKAGED AIR-CONDITIONING SYSTEMS BASED ON RELIABILITY ASSESSMENT

    OpenAIRE

    関口, 圭輔; 中尾, 正喜; 藁谷, 至誠; 植草, 常雄; 羽山, 広文

    2007-01-01

    Water-cooled packaged air-conditioning systems are reevaluated in terms of alleviating the heat island phenomenon in cities and effectively utilizing building rooftops. Up to now, such reliability assessment has been insufficient, and this has limited the use of this kind of air-conditioning system in the information and communications sectors that demand a high reliability. This work has led to the development of a model for evaluating the reliability of water-cooled package air-conditioning...

  7. Concepts and technologies used in contemporary DAQ systems

    CERN Multimedia

    CERN. Geneva

    2004-01-01

    based trigger processor and event building farms. We have also seen a shift from standard or proprietary bus systems used in event building to GigaBit networks and commodity components, such as PCs. With the advances in processing power, network throughput, and storage technologes, today's data rates in large experiments routinely reach hundreds of MegaBytes/s. We will present examples of contemporary DAQ systems from different experiments, try to identify or categorize new approaches, and will compare the performance and throughput of existing DAQ systems with the projected data rates of the LHC experiments to see how close we have come to accomplish these goals. We will also tr...

  8. Performance enhancement of a subcooled cold storage air conditioning system

    International Nuclear Information System (INIS)

    Hsiao, M.-J.; Cheng, C.-H.; Huang, M.-C.; Chen, S.-L.

    2009-01-01

    This article experimentally investigates the enhancement of thermal performance for an air conditioning system utilizing a cold storage unit as a subcooler. The cold storage unit is composed of an energy storage tank, liquid-side heat exchanger, suction-side heat exchanger and energy storage material (ESM), water. When the cooling load is lower than the nominal cooling capacity of the system, the cold storage unit can store extra cold energy of the system to subcool the condenser outlet refrigerant. Hence, both the cooling capacity and coefficient of performance (COP) of the system will be increased. This experiment tests the two operation modes: subcooled mode with energy storage and non-subcooled mode without energy storage. The results show that for fixed cooling loads at 3.05 kW, 3.5 kW and 3.95 kW, the COP of the subcooled mode are 16.0%, 15.6% and 14.1% higher than those of the non-subcooled mode, respectively. In the varied cooling load experiments, the COP of the subcooled cold storage air conditioning system is 15.3% higher than the conventional system.

  9. OPSAID Initial Design and Testing Report.

    Energy Technology Data Exchange (ETDEWEB)

    Hurd, Steven A.; Stamp, Jason Edwin [Sandia National Laboratories, Albuquerque, NM; Chavez, Adrian R. [Sandia National Laboratories, Albuquerque, NM

    2007-11-01

    Process Control System (PCS) security is critical to our national security. Yet, there are a number of technological, economic, and educational impediments to PCS owners implementing effective security on their systems. OPSAID (Open PCS Security Architecture for Interoperable Design), a project sponsored by the US Department of Energy's Office of Electricity Delivery and Reliability, aims to address this issue through developing and testing an open source architecture for PCS security. Sandia National Laboratories, along with a team of PCS vendors and owners, have developed and tested this PCS security architecture. This report describes their progress to date.2 AcknowledgementsThe authors acknowledge and thank their colleagues for their assistance with the OPSAID project.Sandia National Laboratories: Alex Berry, Charles Perine, Regis Cassidy, Bryan Richardson, Laurence PhillipsTeumim Technical, LLC: Dave TeumimIn addition, the authors are greatly indebted to the invaluable help of the members of the OPSAID Core Team. Their assistance has been critical to the success and industry acceptance of the OPSAID project.Schweitzer Engineering Laboratory: Rhett Smith, Ryan Bradetich, Dennis GammelTelTone: Ori Artman Entergy: Dave Norton, Leonard Chamberlin, Mark AllenThe authors would like to acknowledge that the work that produced the results presented in this paper was funded by the U.S. Department of Energy/Office of Electricity Delivery and Energy Reliability (DOE/OE) as part of the National SCADA Test Bed (NSTB) Program. Executive SummaryProcess control systems (PCS) are very important for critical infrastructure and manufacturing operations, yet cyber security technology in PCS is generally poor. The OPSAID (Open PCS (Process Control System) Security Architecture for Interoperable Design) program is intended to address these security shortcomings by accelerating the availability and deployment of comprehensive security technology for PCS, both for existing PCS

  10. Open-Phase Condition Detecting System for Transformers in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Ha, Che-Wung; Lee, Do-Hwan

    2015-01-01

    Recently, several events involving the loss of one of the three phases of the offsite power circuit occurred in the US nuclear power plants (NPPs).. In some cases, the open-phase condition existed undetected for an extended period and in other case, was not properly responded to. Accordingly, the Nuclear Regulatory Commission (NRC) requested all license holders to take corrective actions to address the open-phase condition. It was also requested that all holders or applicant for a standard design certification (DC) include a description of a protection system to detect and separate the open circuit into design control document (DCD). Currently, NPPs including Duke Energy, Exelon, and institutes including Electric Power Research Institute (EPRI) are working together to resolve issues associated with detecting an open-phase condition. This paper, using Electromagnetic Transients Program (EMTP), presents a system to detect and address the loss of one of three phases of the offsite power circuit connected to main, auxiliary and standby transformers, which is hard to be detected in the current protection system. This paper, using EMTP, presents a system to detect and address the loss of one of three phases of the offsite power circuit running to MT, UAT or SAT which is hard to be detected in the current protection system. The system presented in this paper will be useful not only for the KHNP to meet the NRC requirement, but also for nuclear power plants at home and abroad to take corrective actions to provide protection from a single phase open circuit condition for offsite power sources

  11. Open-Phase Condition Detecting System for Transformers in Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Che-Wung; Lee, Do-Hwan [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Recently, several events involving the loss of one of the three phases of the offsite power circuit occurred in the US nuclear power plants (NPPs).. In some cases, the open-phase condition existed undetected for an extended period and in other case, was not properly responded to. Accordingly, the Nuclear Regulatory Commission (NRC) requested all license holders to take corrective actions to address the open-phase condition. It was also requested that all holders or applicant for a standard design certification (DC) include a description of a protection system to detect and separate the open circuit into design control document (DCD). Currently, NPPs including Duke Energy, Exelon, and institutes including Electric Power Research Institute (EPRI) are working together to resolve issues associated with detecting an open-phase condition. This paper, using Electromagnetic Transients Program (EMTP), presents a system to detect and address the loss of one of three phases of the offsite power circuit connected to main, auxiliary and standby transformers, which is hard to be detected in the current protection system. This paper, using EMTP, presents a system to detect and address the loss of one of three phases of the offsite power circuit running to MT, UAT or SAT which is hard to be detected in the current protection system. The system presented in this paper will be useful not only for the KHNP to meet the NRC requirement, but also for nuclear power plants at home and abroad to take corrective actions to provide protection from a single phase open circuit condition for offsite power sources.

  12. Step response and frequency response of an air conditioning system

    NARCIS (Netherlands)

    Crommelin, R.D.; Jackman, P.J.

    1978-01-01

    A system of induction units of an existing air conditioning system has been analyzed with respect to its dynamic properties. Time constants were calculated and measured by analogue models. Comparison with measurements at the installation itself showed a reasonable agreement. Frequency responses were

  13. Experimental investigation of a novel configuration of desiccant based evaporative air conditioning system

    International Nuclear Information System (INIS)

    Uçkan, İrfan; Yılmaz, Tuncay; Hürdoğan, Ertaç; Büyükalaca, Orhan

    2013-01-01

    Highlights: ► A novel desiccant based evaporative cooling system is developed and tested. ► Cooling capacity, COP and energy consumption of the system are evaluated. ► Indoor air conditions are in the range of thermal comfort zone and expanded comfort zone. ► Designing of the system have considerable effect on the energy consumption. - Abstract: A novel configuration of desiccant based evaporative cooling system for air conditioning application is developed and tested. At the beginning of the design stage of the system, an analysis is carried out in order to maximize the performance of the system. It is found based on configuration that outdoor air must be used for regeneration to increase performance of the system and so three air channels are used. Experiments are carried out to investigate the total performance of the system and performance of the components used during summer season in a hot and humid climate. Effectiveness values for both heat exchangers and evaporative coolers are calculated through this work. In addition to the cooling capacity, coefficient of performance (COP) and energy consumption of the system are also evaluated. Results show that the effectiveness for the heat exchangers and evaporative coolers are very high under different outdoor conditions. It is also shown from the results that indoor air conditions are in the range of thermal comfort zone defined by ASHRAE and expanded comfort zone for evaporative air conditioning applications.

  14. ANALYSIS OF OPERATING INSTRUMENT LANDING SYSTEM ACCURACY UNDER SIMULATED CONDITIONS

    Directory of Open Access Journals (Sweden)

    Jerzy MERKISZ

    2017-03-01

    Full Text Available The instrument landing system (ILS is the most popular landing aid in the world. It is a distance-angled support system for landing in reduced visibility, while its task is the safe conduct of the aircraft from the prescribed course landing on the approach path. The aim of this study is to analyse the correctness of the ILS in simulated conditions. The study was conducted using a CKAS MotionSim5 flight simulator in the Simulation Research Laboratory of the Institute of Combustion Engines and Transport at Poznan University of Technology. With the advancement of technical equipment, it was possible to check the operation of the system in various weather conditions. Studies have shown that the impact of fog, rain and snow on the correct operation of the system is marginal. Significant influence has been observed, however, during landing in strong winds.

  15. System for stress corrosion conditions tests on PWR reactors

    International Nuclear Information System (INIS)

    Castro, Andre Cesar de Jesus

    2007-01-01

    The study of environmentally assisted cracking (EAC) involves the consideration and evaluation of the inherent compatibility between a material and the environment under conditions of either applied or residual stress. EAC is a critical problem because equipment, components and structure are subject to the influence of mechanical stress, water environment of different composition, temperature and different material history. Testing for resistance to EAC is one of the most effective ways to determine the interrelationships among this variables on the process of EAC. Up to now, several experimental techniques have been developed worldwide, which address different aspects of environmental caused damage. Constant loading of CT specimens test is a typical example of test, which is used for the estimation of parameters of stress corrosion cracking. To assess the initiation stages and kinetics of crack growth, the testing facility should allow active loading of specimens in the environment that is close to the actual operation conditions of assessed component. This paper presents a testing facility for stress corrosion cracking to be installed at CDTN, which was designed and developed at CDTN. The facility is used to carry out constant load tests under simulated PWR environment, where temperature, water pressure and chemistry are controlled, which are considered the most important factors in SCC. Also, the equipment operational conditions, its applications, and restrictions are presented. The system was developed to operate at temperature until 380 degree C and pressure until 180 bar. It consists in a autoclave stuck at a mechanical system, responsible of producing load , a water treatment station, and a data acquisition system. This testing facility allows the evaluation of cracking progress, especially at PWR reactor. (author) operational conditions. (author)

  16. Monitoring and analysis of an absorption air-conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Perez de Vinaspre, M.; Bourouis, M.; Coronas, A. [Centro de Innovacion Tecnologica en Revalorizacion Energetica y Refrigeracion, Tarragona (Spain); Garcia, A.; Soto, V.; Pinazo, J.M. [E.T.S. Ingenieros Industriales, Valencia (Spain)

    2004-09-01

    In the last few years, high-energy consumption due to air-conditioning has led to a growing interest in the efficient use of energy in buildings. Although simulation programs have always been the main tools for analyzing energy in buildings, the reliability of their results is often compromised by a lack of certainty to reflect real conditions. The aim of this work is to monitorize and analyze the thermal behavior of an absorption-based air-conditioning installation of a university building in Tarragona, Spain. The existing monitoring system of the installation has been improved by implementing additional sensors and flow meters. The data has been stored during summer 2002 and used to assess the energy balance of the air-conditioning installation and the operational regime of the absorption chiller. [Author].

  17. Assessing the reliability of the short form 12 (SF-12) health survey in adults with mental health conditions: a report from the wellness incentive and navigation (WIN) study.

    Science.gov (United States)

    Huo, Tianyao; Guo, Yi; Shenkman, Elizabeth; Muller, Keith

    2018-02-13

    Although Short Form (SF)-12 × 2® has been extensively studied and used as a valid measure of health-related quality of life in a variety of population groups, no systematic studies have described the reliability of the measure in patients with behavioral conditions or serious mental illness (SMI). We assessed the internal consistency, split-half reliability and annual test-retest correlations in a sample of 1587 participants with either a combination of physical and behavioral conditions or SMI. The Mosier's alpha was 0.70 for the Physical Composite Scale (PCS) and 0.69 for the Mental Health Composite Scale (MCS), indicating good internal consistency. We observed strong correlations between physical functioning, physical role and body pain scales (r = 0.55-0.56), and between social functioning, emotional role, and mental health (r = 0.53-0.58). We calculated split-half reliabilities to be 0.74 for physical functioning, 0.75 for physical role, 0.73 for emotional role and 0.65 for mental health respectively. We assessed the annual test-retest correlation using intraclass correlation (ICC) and found an ICC of 0.61 for PCS and 0.57 for MCS composite scores, adjusting for age, sex, race/ethnicity, and CRG. We found no decline in the correlations between baseline and the following study years until year 3. Our results encourage using SF-12v2® to assess health-related quality of life in the Medicaid population with combined physical and behavioral conditions or similar cohorts. The WIN study was registered with clinicaltrials.gov on April 22, 2015. NCT02440906 . Retrospectively registered.

  18. Assessment of MPPT Techniques During the Faulty Conditions of PV System

    Directory of Open Access Journals (Sweden)

    Bhukya Krishna Naick

    2018-01-01

    Full Text Available The contribution of Distributed Generation (DG systems like wind energy systems and solar Photovoltaic (PV systems on the generation of electricity has increased. Out of these DG systems, the PV systems have gained wide popularity, because of the availability of solar energy throughout the day. Depending on the size of PV installations, a large number of PV modules can be interconnected in the form of series and parallel connection. Since a large number of modules are interconnected, it is possible for the faults in a PV array to occur due to the failure of protection system, which can cause damage to the PV module and also the decrease in the output power. This paper presents the tracking of a maximum power point under the faulty conditions of 12x5 PV array. The fault conditions that have been considered in the PV array are open circuit fault, line to ground, line to line and failure of bypass diodes. Perturb and observe, incremental conductance and fuzzy logic controller are the maximum power point tracking techniques that have been implemented. For each of the fault conditions, the results have been presented in terms of the maximum power tracked, tracking time and tracking efficiency.

  19. A simulation Model of the Reactor Hall Ventilation and air Conditioning Systems of ETRR-2

    International Nuclear Information System (INIS)

    Abd El-Rahman, M.F.

    2004-01-01

    Although the conceptual design for any system differs from one designer to another. each of them aims to achieve the function of the system required. the ventilation and air conditioning system of reactors hall is one of those systems that really differs but always dose its function for which it is designed. thus, ventilation and air conditioning in some reactor hall constitute only one system whereas in some other ones, they are separate systems. the Egypt Research Reactor-2 (ETRR-2)represents the second type. most studies conducted on ventilation and air conditioning simulation models either in traditional building or for research rectors show that those models were not designed similarly to the model of the hall of ETRR-2 in which ventilation and air conditioning constitute two separate systems.besides, those studies experimented on ventilation and air conditioning simulation models of reactor building predict the temperature and humidity inside these buildings at certain outside condition and it is difficult to predict when the outside conditions are changed . also those studies do not discuss the influences of reactor power changes. therefore, the present work deals with a computational study backed by infield experimental measurements of the performance of the ventilation and air conditioning systems of reactor hall during normal operation at different outside conditions as well as at different levels of reactor power

  20. Distributed mass data acquisition system based on PCs and windows NT for LHD fusion plasma experiment

    International Nuclear Information System (INIS)

    Nakanishi, H.; Kojima, M.; Ohsuna, M.; Komada, S.; Emoto, M.; Sugisaki, H.; Sudo, S.

    2000-12-01

    A new data acquisition and management system has been developed for the LHD experiment. It has the capability to process 100 MB - 1 GB raw data within a few tens seconds after every plasma discharge. It employs wholly distributed and loosely-tied parallel tasking structure through a fast network, and the cluster of the distributed database severs seems to be a virtual macro-machine as a whole. A PC/Windows NT computer is installed for each diagnostics data acquisition of about 30 kinds, and it controls CAMAC digitizers through the optical SCSI extenders. The diagnostic timing system consists of some kinds of VME modules that are installed to remotely control the diagnostic devices in real-time. They can, as a whole system, distribute the synchronous sampling clocks and programmable triggers for measurement digitizers. The data retrieving terminals can access database as application service clients, and are functionally separated from the data acquisition severs by way of the switching Ethernet. (author)

  1. GPU acceleration of preconditioned solvers for ill-conditioned linear systems

    NARCIS (Netherlands)

    Gupta, R.

    2015-01-01

    In this work we study the implementations of deflation and preconditioning techniques for solving ill-conditioned linear systems using iterative methods. Solving such systems can be a time-consuming process because of the jumps in the coefficients due to large difference in material properties. We

  2. System design and analysis of the trans-critical carbon-dioxide automotive air-conditioning system.

    Science.gov (United States)

    Mu, Jing-Yang; Chen, Jiang-Ping; Chen, Zhi-Jiu

    2003-01-01

    As an environmentally harmless and feasible alternate refrigerant, CO2 has attracted worldwide attention, especially in the area of automobile air-conditioning (AAC). The thermal property of CO2 and its trans-critical refrigeration cycle is very different from that of the traditional CFC or HCFC system. The detailed process of CO2 system thermal cycle design and optimization is described in this paper. System prototype and performance test bench were developed to analyze the performance of the CO2 AAC system.

  3. Worldwide collaborative efforts in plasma control software development

    International Nuclear Information System (INIS)

    Penaflor, B.G.; Ferron, J.R.; Walker, M.L.; Humphreys, D.A.; Leuer, J.A.; Piglowski, D.A.; Johnson, R.D.; Xiao, B.J.; Hahn, S.H.; Gates, D.A.

    2008-01-01

    This presentation will describe the DIII-D collaborations with various tokamak experiments throughout the world which have adapted custom versions of the DIII-D plasma control system (PCS) software for their own use. Originally developed by General Atomics for use on the DIII-D tokamak, the PCS has been successfully installed and used for the NSTX experiment in Princeton, the MAST experiment in Culham UK, the EAST experiment in China, and the Pegasus experiment in the University of Wisconsin. In addition to these sites, a version of the PCS is currently being developed for use by the KSTAR tokamak in Korea. A well-defined and robust PCS software infrastructure has been developed to provide a common foundation for implementing the real-time data acquisition and feedback control codes. The PCS infrastructure provides a flexible framework that has allowed the PCS to be easily adapted to fulfill the unique needs of each site. The software has also demonstrated great flexibility in allowing for different computing, data acquisition and real-time networking hardware to be used. A description of the current PCS software architecture will be given along with experiences in developing and supporting the various PCS installations throughout the world

  4. Peculiarities of the risk management system organization in current conditions

    OpenAIRE

    MIKHIN P.O.

    2014-01-01

    Risk-management system organization problem is topical nowadays. The innovation activity is defined as an activity vulnerable to risk and needs more attention. The basic approaches and elements of organization structure development in risk-management system are considered to find out the best structure for business modelling usage. Balance and combination of risk-management system types are required in current conditions.

  5. Instrumentation of air conditioning and ventilation system - R-5 project

    International Nuclear Information System (INIS)

    Kulkarni, P.B.; Naik, C.D.; Narasingha Rao, S.N.

    1977-01-01

    A detailed account of instrumentation proposed for airconditioning and ventilation system in the R-5, 100 MW thermal research reactor, under construction is presented. Controls and instrumentation provided in this system are electronic, pneumatic and hydraulic in nature depending on the application. They cater to the accurate operation of the system and maintain the conditions strictly within desired tolerances. (S.K.K.)

  6. Global stability and tumor clearance conditions for a cancer chemotherapy system

    Science.gov (United States)

    Valle, Paul A.; Starkov, Konstantin E.; Coria, Luis N.

    2016-11-01

    In this paper we study the global dynamics of a cancer chemotherapy system presented by de Pillis et al. (2007). This mathematical model describes the interaction between tumor cells, effector-immune cells, circulating lymphocytes and chemotherapy treatment. By applying the localization method of compact invariant sets, we find lower and upper bounds for these three cells populations. Further, we define a bounded domain in R+,04 where all compact invariant sets of the system are located and provide conditions under which this domain is positively invariant. We apply LaSalle's invariance principle and one result concerning two-dimensional competitive systems in order to derive sufficient conditions for tumor clearance and global asymptotic stability of the tumor-free equilibrium point. These conditions are computed by using bounds of the localization domain and they are given in terms of the chemotherapy treatment. Finally, we perform numerical simulations in order to illustrate our results.

  7. Ice Storage Air-Conditioning System Simulation with Dynamic Electricity Pricing: A Demand Response Study

    Directory of Open Access Journals (Sweden)

    Chi-Chun Lo

    2016-02-01

    Full Text Available This paper presents an optimal dispatch model of an ice storage air-conditioning system for participants to quickly and accurately perform energy saving and demand response, and to avoid the over contact with electricity price peak. The schedule planning for an ice storage air-conditioning system of demand response is mainly to transfer energy consumption from the peak load to the partial-peak or off-peak load. Least Squares Regression (LSR is used to obtain the polynomial function for the cooling capacity and the cost of power consumption with a real ice storage air-conditioning system. Based on the dynamic electricity pricing, the requirements of cooling loads, and all technical constraints, the dispatch model of the ice-storage air-conditioning system is formulated to minimize the operation cost. The Improved Ripple Bee Swarm Optimization (IRBSO algorithm is proposed to solve the dispatch model of the ice storage air-conditioning system in a daily schedule on summer. Simulation results indicate that reasonable solutions provide a practical and flexible framework allowing the demand response of ice storage air-conditioning systems to demonstrate the optimization of its energy savings and operational efficiency and offering greater energy efficiency.

  8. Open system architecture for condition based maintenance applied to a hydroelectric power plant

    Energy Technology Data Exchange (ETDEWEB)

    Amaya, E.J.; Alvares, A.J. [University of Brasilia (UnB), DF (Brazil). Mechanical and Mechatronic Dept.], Emails: eamaya@unb.br, alvares@AlvaresTech.com; Gudwin, R.R. [State University of Campinas (UNICAMP), SP (Brazil). Computer Engineering and Industrial Automation Dept.], E-mail: gudwin@dca.fee.unicamp.br

    2009-07-01

    The hydroelectric power plant of Balbina is implementing a condition based maintenance system applying an open, modular and scalable integrated architecture to provide comprehensive solutions and support to the end users like operational and maintenance team. The system called SIMPREBAL (Predictive Maintenance System of Balbina) is advocate of open standards, in particular through collaborative research programmers. In the developing is clearly understands the need for both, industry standards and a simple to use software development tool chain, supporting the development of complex condition based maintenance systems with multiple partners. The Open System Architecture for Condition Based Maintenance (OSA-CBM) is a standard that consider seven hierarchic layers that represent a logic transition or performed data flow from the data acquisition layer, through the intermediates layers as signal processing, condition monitor, health assessment, prognostics and decision support, to arrive to the presentation layer. SIMPREBAL is being implementing as an OSA-CBM software framework and tool set that allows the creation of truly integrated, comprehensive maintenance solutions through the internet. This paper identifies specific benefits of the application of the OSA-CBM in comprehensive solutions of condition based maintenance for a hydroelectric power plant. (author)

  9. Multi-kanban mechanism for personal computer disassembly

    Science.gov (United States)

    Udomsawat, Gun; Gupta, Surendra M.; Kamarthi, Sagar V.

    2004-12-01

    The use of personal computers (PCs) continues to increase every year. According to a 1999 figure, 50 percent of all US households owned PCs, a figure that continues to rise every year. With continuous development of sophisticated software, PCs are becoming increasingly powerful. In addition, the price of a PC continues to steadily decline. Furthermore, the typical life of a PC in the workplace is approximately two to three years while in the home it is three to five years. As these PCs become obsolete, they are replaced and the old PCs are disposed of. It is estimated that between 14 and 20 million PCs are retired annually in the US. While 20 to 30% of the units may be resold, the others are discarded. These discards represent a significant potential source of lead for the waste stream. In some communities, waste cathode ray tubes (CRTs) represent the second largest source of lead in the waste stream after vehicular lead acid batteries. PCs are, therefore, not suitable for dumping in landfills. Besides, several components of a PC can be reused and then there are other valuable materials that can also be harvested. And with the advent of product stewardship, product recovery is the best solution for manufacturers. Disassembly line is perhaps the most suitable set up for disassembling PCs. However, planning and scheduling of disassembly on a disassembly line is complicated. In this paper, we discuss some of the complications including product arrival, demand arrival, inventory fluctuation and production control mechanisms. We then show how to overcome them by implementing a multi-kanban mechanism in the PC disassembly line setting. The multi-kanban mechanism relies on dynamic routing of kanbans according to the state of the system. We investigate the multi-kanban mechanism using simulation and demonstrate that this mechanism is superior to the traditional push system in terms of controlling the system"s inventory while maintaining a decent customer service level.

  10. Management of air-conditioning systems in residential buildings by using fuzzy logic

    Directory of Open Access Journals (Sweden)

    Sohair F. Rezeka

    2015-06-01

    Full Text Available There has been a rising concern in reducing the energy consumption in buildings. Heating, ventilation and air-conditioning system is the biggest consumer of energy in buildings. In this study, management of the air-conditioning system of a building for efficient energy operation and comfortable environment is investigated. The strategy used in this work depends on classifying the rooms to three different groups: very important rooms, important rooms and normal rooms. The total mass flow rate is divided between all rooms by certain percentage using a fuzzy-logic system to get the optimum performance for each room. The suggested Building Management System (BMS was found capable of keeping errors in both temperature and humidity within the acceptable limits at different operating conditions. The BMS can save the chilled/hot water flow rate and the cooling/heating capacity of rooms.

  11. Performance advancement of solar air-conditioning through integrated system design for building

    International Nuclear Information System (INIS)

    Fong, K.F.; Lee, C.K.

    2014-01-01

    This study is to advance the energy performance of solar air-conditioning system through appropriate component integration from the absorption refrigeration cycle and proper high-temperature cooling. In the previous studies, the solar absorption air-conditioning using the working pair of water – lithium bromide (H 2 O–LiBr) is found to have prominent primary energy saving than the conventional compression air-conditioning for buildings in the hot-humid climate. In this study, three integration strategies have been generated for solar cooling, namely integrated absorption air-conditioning; integrated absorption-desiccant air-conditioning; and integrated absorption-desiccant air-conditioning for radiant cooling. To realize these ideas, the working pair of ammonia – water (NH 3 –H 2 O) was used in the absorption cycle, rather than H 2 O–LiBr. As such, the evaporator and the condenser can be separate from the absorption refrigeration cycle for the new configuration of various integrated design alternatives. Through dynamic simulation, the year-round primary energy saving of the proposed integration strategies for solar NH 3 –H 2 O absorption air-conditioning systems could be up to 50.6% and 25.5%, as compared to the conventional compression air-conditioning and the basic solar H 2 O–LiBr absorption air-conditioning respectively. Consequently, carbon reduction of building air-conditioning can be achieved more effectively through the integrated system design in the hot and humid cities. - Highlights: • Three integration strategies, IAAU, IADAU and IADAU-RC, are proposed to advance solar air-conditioning. • NH 3 –H 2 O is adopted for absorption refrigeration instead of H 2 O–LiBr. • Separate evaporator and condenser, desiccant cooling and radiant cooling are designed for IADAU-RC. • IADAU-RC can have 50.6% primary energy saving against the conventional air-conditioning

  12. Component and system simulation models for High Flux Isotope Reactor

    International Nuclear Information System (INIS)

    Sozer, A.

    1989-08-01

    Component models for the High Flux Isotope Reactor (HFIR) have been developed. The models are HFIR core, heat exchangers, pressurizer pumps, circulation pumps, letdown valves, primary head tank, generic transport delay (pipes), system pressure, loop pressure-flow balance, and decay heat. The models were written in FORTRAN and can be run on different computers, including IBM PCs, as they do not use any specific simulation languages such as ACSL or CSMP. 14 refs., 13 figs

  13. Turning challenges into design principles: Telemonitoring systems for patients with multiple chronic conditions.

    Science.gov (United States)

    Sultan, Mehwish; Kuluski, Kerry; McIsaac, Warren J; Cafazzo, Joseph A; Seto, Emily

    2018-01-01

    People with multiple chronic conditions often struggle with managing their health. The purpose of this research was to identify specific challenges of patients with multiple chronic conditions and to use the findings to form design principles for a telemonitoring system tailored for these patients. Semi-structured interviews with 15 patients with multiple chronic conditions and 10 clinicians were conducted to gain an understanding of their needs and preferences for a smartphone-based telemonitoring system. The interviews were analyzed using a conventional content analysis technique, resulting in six themes. Design principles developed from the themes included that the system must be modular to accommodate various combinations of conditions, reinforce a routine, consolidate record keeping, as well as provide actionable feedback to the patients. Designing an application for multiple chronic conditions is complex due to variability in patient conditions, and therefore, design principles developed in this study can help with future innovations aimed to help manage this population.

  14. Intelligent condition monitoring of railway catenary systems : A Bayesian Network approach

    NARCIS (Netherlands)

    Wang, H.; Nunez Vicencio, Alfredo; Dollevoet, R.P.B.J.; Liu, Zhigang; Chen, Junwen; Spiryagin, Maksym; Gordon, Timothy; Cole, Colin; McSweeney, Tim

    2017-01-01

    This study proposes a Bayesian network (BN) dedicated for the intelligent condition monitoring of railway catenary systems. It combines five types of measurements related to catenary condition, namely the contact wire stagger, contact wire height, pantograph head displacement, pantograph head

  15. Business cases for product configuration systems

    DEFF Research Database (Denmark)

    Shafiee, Sara; Kristjansdottir, Katrin; Hvam, Lars

    In the recent years, product configuration systems (PCSs) have received greater attention from industries providing customized products as a response to increased demand to fulfil diverse customers’ needs for customized products. Before developing a PCS, a well-established business case has...... to be made in order to secure the success and delivery of the project as it will increase the commitment from the business side. This paper presents a framework for supporting the development of business cases for PCSs and discusses the experiences from multiple case studies benefiting from the suggested...

  16. A computational model of conditioning inspired by Drosophila olfactory system.

    Science.gov (United States)

    Faghihi, Faramarz; Moustafa, Ahmed A; Heinrich, Ralf; Wörgötter, Florentin

    2017-03-01

    Recent studies have demonstrated that Drosophila melanogaster (briefly Drosophila) can successfully perform higher cognitive processes including second order olfactory conditioning. Understanding the neural mechanism of this behavior can help neuroscientists to unravel the principles of information processing in complex neural systems (e.g. the human brain) and to create efficient and robust robotic systems. In this work, we have developed a biologically-inspired spiking neural network which is able to execute both first and second order conditioning. Experimental studies demonstrated that volume signaling (e.g. by the gaseous transmitter nitric oxide) contributes to memory formation in vertebrates and invertebrates including insects. Based on the existing knowledge of odor encoding in Drosophila, the role of retrograde signaling in memory function, and the integration of synaptic and non-synaptic neural signaling, a neural system is implemented as Simulated fly. Simulated fly navigates in a two-dimensional environment in which it receives odors and electric shocks as sensory stimuli. The model suggests some experimental research on retrograde signaling to investigate neural mechanisms of conditioning in insects and other animals. Moreover, it illustrates a simple strategy to implement higher cognitive capabilities in machines including robots. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Improving reliability of state estimation programming and computing suite based on analyzing a fault tree

    Directory of Open Access Journals (Sweden)

    Kolosok Irina

    2017-01-01

    Full Text Available Reliable information on the current state parameters obtained as a result of processing the measurements from systems of the SCADA and WAMS data acquisition and processing through methods of state estimation (SE is a condition that enables to successfully manage an energy power system (EPS. SCADA and WAMS systems themselves, as any technical systems, are subject to failures and faults that lead to distortion and loss of information. The SE procedure enables to find erroneous measurements, therefore, it is a barrier for the distorted information to penetrate into control problems. At the same time, the programming and computing suite (PCS implementing the SE functions may itself provide a wrong decision due to imperfection of the software algorithms and errors. In this study, we propose to use a fault tree to analyze consequences of failures and faults in SCADA and WAMS and in the very SE procedure. Based on the analysis of the obtained measurement information and on the SE results, we determine the state estimation PCS fault tolerance level featuring its reliability.

  18. High-level trigger system for the LHC ALICE experiment

    CERN Document Server

    Bramm, R; Lien, J A; Lindenstruth, V; Loizides, C; Röhrich, D; Skaali, B; Steinbeck, T M; Stock, Reinhard; Ullaland, K; Vestbø, A S; Wiebalck, A

    2003-01-01

    The central detectors of the ALICE experiment at LHC will produce a data size of up to 75 MB/event at an event rate less than approximately equals 200 Hz resulting in a data rate of similar to 15 GB/s. Online processing of the data is necessary in order to select interesting (sub)events ("High Level Trigger"), or to compress data efficiently by modeling techniques. Processing this data requires a massive parallel computing system (High Level Trigger System). The system will consist of a farm of clustered SMP-nodes based on off- the-shelf PCs connected with a high bandwidth low latency network.

  19. Ice thermal storage air conditioning system for electric load leveling; Denryoku heijunka to hyochikunetsu system

    Energy Technology Data Exchange (ETDEWEB)

    Shigenaga, Y. [Daikin Industries Ltd., Osaka (Japan)

    1998-08-15

    Thermal storage air conditioning system is the one to use energy stored into thermal storing materials by using night electric power and to operate effective air conditioning. Therefore, as load can be treated by the stored energy, volume of the apparatus can be reduced. And, by reduction of the consumed power at day time, it can contribute to leveling of electric power demand. In general, there are two types in the thermal storage method: one is a method to store as thermal energy, and the other is that to store as chemical energy. For conditions required for the storing materials, important elements on their actual uses are not only physical properties such as large thermal storage per unit and easy thermal in- and out-puts, but also safety, long-term reliability, and easy receiving and economics containing future. The ice thermal storage air conditioning system is classified at the viewpoint of type of ice, kind of thermal storing medium, melting method on using cooling and heating, kinds of thermal medium on cooling and heating. 3 refs., 5 figs., 2 tabs.

  20. Arsenic-induced stress activates sulfur metabolism in different organs of garlic (Allium sativum L.) plants accompanied by a general decline of the NADPH-generating systems in roots.

    Science.gov (United States)

    Ruíz-Torres, Carmelo; Feriche-Linares, Rafael; Rodríguez-Ruíz, Marta; Palma, José M; Corpas, Francisco J

    2017-04-01

    Arsenic (As) contamination is a major environmental problem which affects most living organisms from plants to animals. This metalloid poses a health risk for humans through its accumulation in crops and water. Using garlic (Allium sativum L.) plants as model crop exposed to 200μM arsenate, a comparative study among their main organs (roots and shoots) was made. The analysis of arsenic, glutathione (GSH), phytochelatins (PCs) and lipid peroxidation contents with the activities of antioxidant enzymes (catalase, superoxide dismutase, ascorbate-glutathione cycle), and the main components of the NADPH-generating system, including glucose-6-phosphate dehydrogenase (G6PDH), 6-phosphogluconate dehydrogenase (6PGDH), NADP-malic enzyme (NADP-ME) and NADP-isocitrate dehydrogenase (NADP-ICDH) was carried out. Data showed a correlation among arsenic accumulation in the different organs, PCs content and the antioxidative response, with a general decline of the NADPH-generating systems in roots. Overall, our results demonstrate that there are clear connections between arsenic uptake, increase of their As-chelating capacity in roots and a decline of antioxidative enzyme activities (catalase and the ascorbate peroxidase) whose alteration provoked As-induced oxidative stress. Thus, the data suggest that roots act as barrier of arsenic mediated by a prominent sulfur metabolism which is characterized by the biosynthesis of high amount of PCs. Copyright © 2017 Elsevier GmbH. All rights reserved.

  1. 76 FR 39763 - Special Conditions: Boeing Model 787-8 Airplane; Interaction of Systems and Structures...

    Science.gov (United States)

    2011-07-07

    ... Conditions No. 25-354A-SC] Special Conditions: Boeing Model 787-8 Airplane; Interaction of Systems and..., electronic flight control system control surface awareness, HIRF protection, limit engine torque loads for... standards. A special condition is needed to require consideration of the effects of systems on the...

  2. Functional approach to the problem of self-gravitating systems: Conditions of integrability

    International Nuclear Information System (INIS)

    Filippi, Simonetta; Ruffini, Remo; Sepulveda, Alonso

    2002-01-01

    Using a functional method based on the introduction of a velocity potential to solve the Euler, continuity and Poisson equations, a new analytic study of the equilibrium of self-gravitating rotating systems with a polytropic equation of state has permitted the formulation of the conditions of integrability. For the polytropic index n=1 in the incompressible case (∇·v(vector sign)=0), we are able to find the conditions for solving the problem of the equilibrium of polytropic self-gravitating systems that rotate and have nonuniform vorticity. This work contains the conditions which give analytic and quasi-analytic solutions for the equilibrium of polytropic stars and galactic systems in Newtonian gravity. In special cases, explicit analytic solutions are presented

  3. SSYST, Modular System for Transient Fuel Rod Behaviour Under Accident Condition

    International Nuclear Information System (INIS)

    Gulden, W.; Meyder, R.; Borgwaldt, H.

    1987-01-01

    1 - Description of problem or function: SSYST is a code system for analyzing transient fuel rod behaviour under off-normal conditions, developed jointly by the Institut fuer Kernenergetik und Energie-systeme (IKE), Stuttgart, and Kernforschungszentrum Karlsruhe (KfK) under contract for the Projekt Nukleare Sicherheit (PNS) at KfK. Main differences versus codes with similar applications are: (1) an open-ended modular code organisation; (2) a preference for simple models, wherever possible. While feature (1) makes SSYST a very flexible tool, easily adapted to changing requirements, feature (2) leads to short execution times. The analysis of transient rod behaviour under LOCA boundary conditions takes 2 minutes CPU time on IBM 3033, so that extensive parametric studies are feasible. Main differences between SSYST-3 and previous versions are related to a general clean-up of the code system, which reduces the implementation effort: - advanced modules for cladding deformation and oxidation and reflooding conditions are included; - an input processor thoroughly checks all input data

  4. Correlation functions for Hermitian many-body systems: Necessary conditions

    International Nuclear Information System (INIS)

    Brown, E.B.

    1994-01-01

    Lee [Phys. Rev. B 47, 8293 (1993)] has shown that the odd-numbered derivatives of the Kubo autocorrelation function vanish at t=0. We show that this condition is based on a more general property of nondiagonal Kubo correlation functions. This general property provides that certain functional forms (e.g., simple exponential decay) are not admissible for any symmetric or antisymmetric Kubo correlation function in a Hermitian many-body system. Lee's result emerges as a special case of this result. Applications to translationally invariant systems and systems with rotational symmetries are also demonstrated

  5. Multiplex conditional mutagenesis in zebrafish using the CRISPR/Cas system.

    Science.gov (United States)

    Yin, L; Maddison, L A; Chen, W

    2016-01-01

    The clustered regularly interspaced short palindromic repeat (CRISPR)/CRISPR-associated protein (Cas) system is a powerful tool for genome editing in numerous organisms. However, the system is typically used for gene editing throughout the entire organism. Tissue and temporal specific mutagenesis is often desirable to determine gene function in a specific stage or tissue and to bypass undesired consequences of global mutations. We have developed the CRISPR/Cas system for conditional mutagenesis in transgenic zebrafish using tissue-specific and/or inducible expression of Cas9 and U6-driven expression of sgRNA. To allow mutagenesis of multiple targets, we have isolated four distinct U6 promoters and designed Golden Gate vectors to easily assemble transgenes with multiple sgRNAs. We provide experimental details on the reagents and applications for multiplex conditional mutagenesis in zebrafish. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Study for Determining the Testing Condition of Compressor and Turbine System

    International Nuclear Information System (INIS)

    Sri Sudadiyo

    2009-01-01

    Study for Determining the Testing Condition of Compressor and Turbine System. From the viewpoint of energy system and environment, the concept for nuclear reactors of the generation IV have good potential for electricity and heat generation devices in producing hydrogen. These gas cooled nuclear reactors employ turbine cycle in transferring the heat. To analyses that coolant system, it is proposed a model of compressor and turbine system with power 3 kW. The used working fluid was hydrogen that be burnt with air within combustion chamber, then be expanded through a turbine for getting shaft work that will be used in driving compressor and generator. This study is aimed to determine the optimum testing conditions of gas turbine system. The used method is by applying the balance equations of energy, mass, and momentum. Gas turbine and compressor were placed at the single shaft, in which it was about 55 percent of power output for running the compressor. Under the testing condition for the speed of 20305 rpm, it was obtained thermal efficiency of the turbine cycle approximate 18 % (equal to the Carnot efficiency ratio 65 %), so that it is properly developed for the development of nuclear power installation in supporting the electricity energy demand and it will be very promising for the future facility. (author)

  7. Multiprocessor systems for real-time data acquisition on the Asdex upgrade and future plasma experiments

    International Nuclear Information System (INIS)

    Zilker, M.; Hallatschek, K.; Heimann, P.; Hertweck, F.

    1999-01-01

    In this paper we present our transputer-based multitop multiprocessor systems for data acquisition, which are currently used on the Asdex upgrade experiment. The bandwidth of these systems goes from low-speed like the calorimetry diagnostic up to highspeed and large data volume systems like the soft-X-ray and Mirnov diagnostics, which collect several hundreds of megabytes of data during a plasma discharge of ∼8 s. Further, we present the multitop-MX, a newly developed system based on transputers and powerPCs, which provides real-time facilities for analysing the acquired data, to generate necessary information for the dynamic adaptation of sample rates, and to deliver triggers when certain events in the plasma are detected. The algorithm running on the powerPCs performs a wavelet like time-frequency transform. In the last part we give an outlook how to build the next generation of data acquisition systems to be used on the future plasma experiments W7-X and ITER, but also on Asdex upgrade. The hardware of these new distributed systems should be mainly based on established industry standards like the VME-bus, PCI-bus and FiberChannel, but also emerging technologies like SCI (scalable coherent interconnect) should be considered. The systems software should be well designed with object oriented methods to simplify the maintenance process and to enable further expansions and adaptations to new problems in an easy way. (orig.)

  8. Windows Security patch required

    CERN Multimedia

    3004-01-01

    This concerns Windows PCs (XP, 2000, NT) which are NOT centrally managed at CERN for security patches, e.g. home PCs, experiment PCs, portables,... A security hole which can give full privileges on Windows systems needs to be URGENTLY patched. Details of the security hole and hotfix are at: http://cern.ch/it-div/news/hotfix-MS03-026.asp http://www.microsoft.com/technet/security/bulletin/MS03-026.asp

  9. Efficient derivation of multipotent neural stem/progenitor cells from non-human primate embryonic stem cells.

    Directory of Open Access Journals (Sweden)

    Hiroko Shimada

    Full Text Available The common marmoset (Callithrix jacchus is a small New World primate that has been used as a non-human primate model for various biomedical studies. We previously demonstrated that transplantation of neural stem/progenitor cells (NS/PCs derived from mouse and human embryonic stem cells (ESCs and induced pluripotent stem cells (iPSCs promote functional locomotor recovery of mouse spinal cord injury models. However, for the clinical application of such a therapeutic approach, we need to evaluate the efficacy and safety of pluripotent stem cell-derived NS/PCs not only by xenotransplantation, but also allotransplantation using non-human primate models to assess immunological rejection and tumorigenicity. In the present study, we established a culture method to efficiently derive NS/PCs as neurospheres from common marmoset ESCs. Marmoset ESC-derived neurospheres could be passaged repeatedly and showed sequential generation of neurons and astrocytes, similar to that of mouse ESC-derived NS/PCs, and gave rise to functional neurons as indicated by calcium imaging. Although marmoset ESC-derived NS/PCs could not differentiate into oligodendrocytes under default culture conditions, these cells could abundantly generate oligodendrocytes by incorporating additional signals that recapitulate in vivo neural development. Moreover, principal component analysis of microarray data demonstrated that marmoset ESC-derived NS/PCs acquired similar gene expression profiles to those of fetal brain-derived NS/PCs by repeated passaging. Therefore, marmoset ESC-derived NS/PCs may be useful not only for accurate evaluation by allotransplantation of NS/PCs into non-human primate models, but are also applicable to analysis of iPSCs established from transgenic disease model marmosets.

  10. In vitro study of platelet function confirms the contribution of the ultraviolet B (UVB) radiation in the lesions observed in riboflavin/UVB-treated platelet concentrates.

    Science.gov (United States)

    Abonnenc, Mélanie; Sonego, Giona; Crettaz, David; Aliotta, Alessandro; Prudent, Michel; Tissot, Jean-Daniel; Lion, Niels

    2015-09-01

    Platelet inactivation technologies (PITs) have been shown to increase platelet storage lesions (PSLs). This study investigates amotosalen/ultraviolet (UV)A- and riboflavin/UVB-induced platelet (PLT) lesions in vitro. Particular attention is given to the effect of UVB alone on PLTs. Buffy coat-derived PLT concentrates (PCs) were treated with amotosalen/UVA, riboflavin/UVB, or UVB alone and compared to untreated PCs throughout storage. In vitro PLT function was assessed by blood gas and metabolite analyses, flow cytometry-based assays (CD62P, JC-1, annexin V, PAC-1), hypotonic shock response, and static adhesion to fibrinogen-coated wells. In our experimental conditions, riboflavin/UVB-treated PCs showed the most pronounced differences compared to untreated and amotosalen/UVA-treated PCs. The riboflavin/UVB treatment led to a significant increase of anaerobic glycolysis rate despite functional mitochondria, a significant increase of CD62P on Day 2, and a decrease of JC-1 aggregates and increase of annexin V on Day 7. The expression of active GPIIbIIIa (PAC-1) and the adhesion to fibrinogen was significantly increased from Day 2 of storage in riboflavin/UVB-treated PCs. Importantly, we showed that these lesions were caused by the UVB radiation alone, independently of the presence of riboflavin. The amotosalen/UVA-treated PCs confirmed previously published results with a slight increase of PSLs compared to untreated PCs. Riboflavin/UVB-treated PCs present significant in vitro PSLs compared to untreated PCs. These lesions are caused by the UVB radiation alone and probably involve the generation of reactive oxygen species. The impact of these observations on clinical use must be investigated. © 2015 AABB.

  11. 76 FR 8316 - Special Conditions: Gulfstream Model GVI Airplane; Interaction of Systems and Structures

    Science.gov (United States)

    2011-02-14

    ... system reliability. These special conditions establish a level of safety that neither raises nor lowers... airplane flight conditions following an in-flight occurrence and that are included in the flight manual (e... conditions may be required by other sections of 14 CFR part 25 regardless of calculated system reliability...

  12. Developing wearable bio-feedback systems: a general-purpose platform.

    Science.gov (United States)

    Bianchi, Luigi; Babiloni, Fabio; Cincotti, Febo; Arrivas, Marco; Bollero, Patrizio; Marciani, Maria Grazia

    2003-06-01

    Microprocessors, even those in PocketPCs, have adequate power for many real-time biofeedback applications for disabled people. This power allows design of portable or wearable devices that are smaller and lighter, and that have longer battery life compared to notebook-based systems. In this paper, we discuss a general-purpose hardware/software solution based on industrial or consumer devices and a C++ framework. Its flexibility and modularity make it adaptable to a wide range of situations. Moreover, its design minimizes system requirements and programming effort, thus allowing efficient systems to be built quickly and easily. Our design has been used to build two brain computer interface systems that were easily ported from the Win32 platform.

  13. Scattering from correlations in colloidal systems

    International Nuclear Information System (INIS)

    Hayter, J.B.

    1984-01-01

    Colloidal suspensions typically exhibit spatial correlations over distances of order 10-10 4 A, corresponding either to the size of individual particles (e.g., polymer chains, surfactant micelles) or to the range of interaction between particles (e.g., charged polymer lattices at low ionic strength). Apart from having fundamental intrinsic interest, such systems are also extremely useful as model systems with which to study, for example, non-Newtonian hydrodynamics, since temporal correlations are generally much longer lived (10 -8 -10 -3 sec) than those found in simple atomic or small molecular systems (10 -13 -10 -10 sec). Colloids have long been the subject of macroscopic phenomenological research (on rheological properties, for example), but it is only recently that microscopic light, x-ray and neutron scattering techniques have been applied to their study, in large part because of theoretical difficulties in understanding the scattering from dense liquid-like systems of interacting particles. For spherical colloids, such theoretical problems have now been largely overcome, and for anisotropic colloids experimental techniques are being developed which circumvent the intractable theoretical areas. This paper will first review some static light and small-angle neutron scattering (SANS) results on colloidal suspensions, both at equilibrium and in steady-state non-equilibrium situations, and will then discuss some dynamic measurements on polymer solutions and melts made using the neutron spin-echo (NSE) technique. Emphasis is placed on experiments which have a possible counterpart in synchrotron radiation studies. In particular, NSE extends the results of photon correlation spectroscopy (PCS) to larger momentum transfers and shorter time-scales than are available with visible light, and the extension of PCS to short wavelength on a synchrotron source would be of similar fundamental interest

  14. Power conditioning system topology for grid integration of wind and fuell cell energy

    Directory of Open Access Journals (Sweden)

    Marian GAICEANU

    2006-12-01

    Full Text Available This paper shows the topology of the hybrid grid-connected power system and the performances of the front-end three-phase power inverter. The renewable sources of the hybrid power system consist of a solid oxide fuel cell and a wind-turbine. This type of combination is the most efficient one. The proposed topology benefits of the one common DC-AC inverter which injects the generated power into the grid. The architecture diminishes the cost of the power conditioning system. Moreover, due to the power balance control of the entire power conditioning system the bulk dc link electrolytic capacitor is replaced with a small plastic film one. The final power conditioning system has the following advantages: independent control of the reactive power, minimize harmonic current distortion offering a nearly unity power factor operation (0,998 operation capability, dc link voltage regulation (up to 5% ripple in the dc-link voltage in any operated conditions, fast disturbance compensation capability, high reliability, and low cost. The experimental test has been performed and the performances of the grid power inverter are shown.

  15. Full integrated system of real-time monitoring based on distributed architecture for the high temperature engineering test reactor (HTTR)

    International Nuclear Information System (INIS)

    Subekti, Muhammad; Ohno, Tomio; Kudo, Kazuhiko; Takamatsu, Kuniyoshi; Nabeshima, Kunihiko

    2005-01-01

    A new monitoring system scheme based on distributed architecture for the High Temperature Engineering Test Reactor (HTTR) is proposed to assure consistency of the real-time process of expanded system. A distributed monitoring task on client PCs as an alternative architecture maximizes the throughput and capabilities of the system even if the monitoring tasks suffer a shortage of bandwidth. The prototype of the on-line monitoring system has been developed successfully and will be tested at the actual HTTR site. (author)

  16. Traffic supervisory/control system for Kobe-Awaji- Naruto expressway of Honshu-Shikoku Bridge Authority; Honshu Shikoku Renrakukyo Kodan nonyu no Kobe Awaji Naruto jidoshado kotsu kansei shisetsu seigyo system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Toshiba delivered the traffic supervisory/control system for Kobe-Awaji-Naruto expressway of Honshu-Shikoku Bridge Authority opened in May 1998. This traffic supervisory system rapidly exactly collects and services the information on the expressway of 89km including Akashi Kaikyo bridge and O-Naruto bridge. The facility control system totally efficiently maintains and controls various facilities for lighting and air circulation of tunnels on the expressway. The previous control system transmitted road information on traffic volume and traffic congestion to offices by using specific lines and terminals, while this system with a monitoring function using intranet can easily service such information by existing PCs. (translated by NEDO)

  17. Traffic supervisory/control system for Kobe-Awaji- Naruto expressway of Honshu-Shikoku Bridge Authority. Honshu Shikoku Renrakukyo Kodan nonyu no Kobe Awaji Naruto jidoshado kotsu kansei shisetsu seigyo system

    Energy Technology Data Exchange (ETDEWEB)

    1999-03-01

    Toshiba delivered the traffic supervisory/control system for Kobe-Awaji-Naruto expressway of Honshu-Shikoku Bridge Authority opened in May 1998. This traffic supervisory system rapidly exactly collects and services the information on the expressway of 89km including Akashi Kaikyo bridge and O-Naruto bridge. The facility control system totally efficiently maintains and controls various facilities for lighting and air circulation of tunnels on the expressway. The previous control system transmitted road information on traffic volume and traffic congestion to offices by using specific lines and terminals, while this system with a monitoring function using intranet can easily service such information by existing PCs. (translated by NEDO)

  18. Liquid over-feeding air conditioning system and method

    Science.gov (United States)

    Mei, Viung C.; Chen, Fang C.

    1993-01-01

    A refrigeration air conditioning system utilizing a liquid over-feeding operation is described. A liquid refrigerant accumulator-heat exchanger is placed in the system to provide a heat exchange relationship between hot liquid refrigerant discharged from condenser and a relatively cool mixture of liquid and vaporous refrigerant discharged from the evaporator. This heat exchange relationship substantially sub-cools the hot liquid refrigerant which undergoes little or no evaporation across the expansion device and provides a liquid over-feeding operation through the evaporator for effectively using 100 percent of evaporator for cooling purposes and for providing the aforementioned mixture of liquid and vaporous refrigerant.

  19. Analysis of Fukushima unit 2 accident considering the operating conditions of RCIC system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Il, E-mail: sikim@kaeri.re.kr; Park, Jong Hwa; Ha, Kwang Soon; Cho, Song-Won; Song, JinHo

    2016-03-15

    Highlights: • Fukushima unit 2 accident was analyzed using MELCOR 1.8.6. • RCIC operating conditions were assumed and best case was selected. • Effect of RCIC operating condition on accident scenario was found. - Abstract: A severe accident in Fukushima occurred on March 11, 2011 and units 1, 2 and 3 were damaged severely. A tsunami following an earthquake made the supply of electricity power stop, and the safety systems, which use AC or DC power in plants could not operate properly. It is supposed that the degree of core degradation of unit 2 is less serious than in the other plants, and it was estimated that the operation of reactor core isolation cooling (RCIC) system at the initial stage of the accident minimized the core damage through decay heat removal. Although the operating conditions of the RCIC system are not known clearly, it can be important to analyze the accident scenario of unit 2. In this study, best case of the Fukushima unit 2 accident was presented considering the operating conditions of the RCIC system. The effects of operating condition on core degradation and fission product release rate to environment were also examined. In addition, importance of torus room flooding level in the accident analysis was discussed. MELCOR 1.8.6 was used in this research, and the geometries of plant and operating conditions of safety system were obtained from TEPCO through OECD/NEA BSAF Project.

  20. Estimating the Impact of Workplace Bullying: Humanistic and Economic Burden among Workers with Chronic Medical Conditions.

    Science.gov (United States)

    Fattori, A; Neri, L; Aguglia, E; Bellomo, A; Bisogno, A; Camerino, D; Carpiniello, B; Cassin, A; Costa, G; De Fazio, P; Di Sciascio, G; Favaretto, G; Fraticelli, C; Giannelli, R; Leone, S; Maniscalco, T; Marchesi, C; Mauri, M; Mencacci, C; Polselli, G; Quartesan, R; Risso, F; Sciaretta, A; Vaggi, M; Vender, S; Viora, U

    2015-01-01

    Although the prevalence of work-limiting diseases is increasing, the interplay between occupational exposures and chronic medical conditions remains largely uncharacterized. Research has shown the detrimental effects of workplace bullying but very little is known about the humanistic and productivity cost in victims with chronic illnesses. We sought to assess work productivity losses and health disutility associated with bullying among subjects with chronic medical conditions. Participants (N = 1717) with chronic diseases answered a self-administered survey including sociodemographic and clinical data, workplace bullying experience, the SF-12 questionnaire, and the Work Productivity Activity Impairment questionnaire. The prevalence of significant impairment was higher among victims of workplace bullying as compared to nonvictims (SF-12 PCS: 55.5% versus 67.9%, p bullying ranged from 13.9% to 17.4%, corresponding to Italian Purchase Power Parity (PPP) 2010 US$ 4182-5236 yearly. Association estimates were independent and not moderated by concurrent medical conditions. Our findings demonstrate that the burden on workers' quality of life and productivity associated with workplace bullying is substantial. This study provides key data to inform policy-making and prioritize occupational health interventions.

  1. Estimating the Impact of Workplace Bullying: Humanistic and Economic Burden among Workers with Chronic Medical Conditions

    Science.gov (United States)

    Fattori, A.; Neri, L.; Aguglia, E.; Bellomo, A.; Bisogno, A.; Camerino, D.; Carpiniello, B.; Cassin, A.; Costa, G.; De Fazio, P.; Di Sciascio, G.; Favaretto, G.; Fraticelli, C.; Giannelli, R.; Leone, S.; Maniscalco, T.; Marchesi, C.; Mauri, M.; Mencacci, C.; Polselli, G.; Quartesan, R.; Risso, F.; Sciaretta, A.; Vaggi, M.; Vender, S.; Viora, U.

    2015-01-01

    Background. Although the prevalence of work-limiting diseases is increasing, the interplay between occupational exposures and chronic medical conditions remains largely uncharacterized. Research has shown the detrimental effects of workplace bullying but very little is known about the humanistic and productivity cost in victims with chronic illnesses. We sought to assess work productivity losses and health disutility associated with bullying among subjects with chronic medical conditions. Methods. Participants (N = 1717) with chronic diseases answered a self-administered survey including sociodemographic and clinical data, workplace bullying experience, the SF-12 questionnaire, and the Work Productivity Activity Impairment questionnaire. Results. The prevalence of significant impairment was higher among victims of workplace bullying as compared to nonvictims (SF-12 PCS: 55.5% versus 67.9%, p bullying ranged from 13.9% to 17.4%, corresponding to Italian Purchase Power Parity (PPP) 2010 US$ 4182–5236 yearly. Association estimates were independent and not moderated by concurrent medical conditions. Conclusions. Our findings demonstrate that the burden on workers' quality of life and productivity associated with workplace bullying is substantial. This study provides key data to inform policy-making and prioritize occupational health interventions. PMID:26557692

  2. The new ENSDF search system NESSY: IBM/PC nuclear spectroscopy database

    International Nuclear Information System (INIS)

    Boboshin, I.N.; Varlamov, V.V.

    1996-01-01

    The universal relational nuclear structure and decay database NESSY (New ENSDF Search SYstem) developed for the IBM/PC and compatible PCs, and based on the international file ENSDF (Evaluated Nuclear Structure Data File), is described. The NESSY provides the possibility of high efficiency processing (the search and retrieval of any kind of physical data) of the information from ENSDF. The principles of the database development are described and examples of applications are presented. (orig.)

  3. New data acquisition system for the lujan center

    International Nuclear Information System (INIS)

    Nelson, R.; Bowling, P.S.; Cooper, G.M.; Kozlowski, T.

    2001-01-01

    To meet the data acquisition requirements for six new neutron scattering instruments at the Los Alamos Science Center (LANSCE), we are building systems using Web tools, commercial hardware and software, software developed by the controls community, and custom hardware developed by the neutron scattering community. To service these new instruments as well as seven existing instruments, our data acquisition system needs common software and hardware core capabilities and the means to flexibly integrate them while differentiating the needs of the diverse instrument suite. Neutron events are captured and processed in VXI modules while controls for sample environment and beam line setup are processed with PCs. Typically users access the system through web browsers. (author)

  4. New data acquisition system for the lujan center

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, R.; Bowling, P.S.; Cooper, G.M.; Kozlowski, T. [Los Alamos National Loboratory, Los Alamos, NM (United States)

    2001-03-01

    To meet the data acquisition requirements for six new neutron scattering instruments at the Los Alamos Science Center (LANSCE), we are building systems using Web tools, commercial hardware and software, software developed by the controls community, and custom hardware developed by the neutron scattering community. To service these new instruments as well as seven existing instruments, our data acquisition system needs common software and hardware core capabilities and the means to flexibly integrate them while differentiating the needs of the diverse instrument suite. Neutron events are captured and processed in VXI modules while controls for sample environment and beam line setup are processed with PCs. Typically users access the system through web browsers. (author)

  5. Power system security enhancement with unified power flow controller under multi-event contingency conditions

    Directory of Open Access Journals (Sweden)

    S. Ravindra

    2017-03-01

    Full Text Available Power system security analysis plays key role in enhancing the system security and to avoid the system collapse condition. In this paper, a novel severity function is formulated using transmission line loadings and bus voltage magnitude deviations. The proposed severity function and generation fuel cost objectives are analyzed under transmission line(s and/or generator(s contingency conditions. The system security under contingency conditions is analyzed using optimal power flow problem. An improved teaching learning based optimization (ITLBO algorithm has been presented. To enhance the system security under contingency conditions in the presence of unified power flow controller (UPFC, it is necessary to identify an optimal location to install this device. Voltage source based power injection model of UPFC, incorporation procedure and optimal location identification strategy based on line overload sensitivity indexes are proposed. The entire proposed methodology is tested on standard IEEE-30 bus test system with supporting numerical and graphical results.

  6. Evaluation of Rankine cycle air conditioning system hardware by computer simulation

    Science.gov (United States)

    Healey, H. M.; Clark, D.

    1978-01-01

    A computer program for simulating the performance of a variety of solar powered Rankine cycle air conditioning system components (RCACS) has been developed. The computer program models actual equipment by developing performance maps from manufacturers data and is capable of simulating off-design operation of the RCACS components. The program designed to be a subroutine of the Marshall Space Flight Center (MSFC) Solar Energy System Analysis Computer Program 'SOLRAD', is a complete package suitable for use by an occasional computer user in developing performance maps of heating, ventilation and air conditioning components.

  7. Dynamics of the plasma current sheath in plasma focus discharges in different gases

    Energy Technology Data Exchange (ETDEWEB)

    Vinogradov, V. P.; Krauz, V. I., E-mail: krauz-vi@nrcki.ru [National Research Center Kurchatov Institute (Russian Federation); Mokeev, A. N. [Project Center ITER (Russian Federation); Myalton, V. V.; Kharrasov, A. M. [National Research Center Kurchatov Institute (Russian Federation)

    2016-12-15

    The shape of the plasma current sheath (PCS) in the final stage of its radial compression, the dynamics of pinching, and the subsequent pinch decay in plasma focus (PF) discharges in different gases are studied using an improved multichannel system of electron-optical plasma photography and a newly elaborated synchronization system. The PCS structure in discharges in heavy gases (Ne, Ar) is found to differ significantly from that in discharges in hydrogen and deuterium. The influence of a heavy gas (Xe) additive to hydrogen and deuterium on the structure and compression dynamics of the PCS is investigated.

  8. Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Wetter, Michael

    2009-06-17

    This paper presents a freely available Modelica library for building heating, ventilation and air conditioning systems. The library is based on the Modelica.Fluid library. It has been developed to support research and development of integrated building energy and control systems. The primary applications are controls design, energy analysis and model-based operation. The library contains dynamic and steady-state component models that are applicable for analyzing fast transients when designing control algorithms and for conducting annual simulations when assessing energy performance. For most models, dimensional analysis is used to compute the performance for operating points that differ from nominal conditions. This allows parameterizing models in the absence of detailed geometrical information which is often impractical to obtain during the conceptual design phase of building systems. In the first part of this paper, the library architecture and the main classes are described. In the second part, an example is presented in which we implemented a model of a hydronic heating system with thermostatic radiator valves and thermal energy storage.

  9. The analytical solution for drug delivery system with nonhomogeneous moving boundary condition

    Science.gov (United States)

    Saudi, Muhamad Hakimi; Mahali, Shalela Mohd; Harun, Fatimah Noor

    2017-08-01

    This paper discusses the development and the analytical solution of a mathematical model based on drug release system from a swelling delivery device. The mathematical model is represented by a one-dimensional advection-diffusion equation with nonhomogeneous moving boundary condition. The solution procedures consist of three major steps. Firstly, the application of steady state solution method, which is used to transform the nonhomogeneous moving boundary condition to homogeneous boundary condition. Secondly, the application of the Landau transformation technique that gives a significant impact in removing the advection term in the system of equation and transforming the moving boundary condition to a fixed boundary condition. Thirdly, the used of separation of variables method to find the analytical solution for the resulted initial boundary value problem. The results show that the swelling rate of delivery device and drug release rate is influenced by value of growth factor r.

  10. Computer Simulation of Complex Power System Faults under various Operating Conditions

    International Nuclear Information System (INIS)

    Khandelwal, Tanuj; Bowman, Mark

    2015-01-01

    A power system is normally treated as a balanced symmetrical three-phase network. When a fault occurs, the symmetry is normally upset, resulting in unbalanced currents and voltages appearing in the network. For the correct application of protection equipment, it is essential to know the fault current distribution throughout the system and the voltages in different parts of the system due to the fault. There may be situations where protection engineers have to analyze faults that are more complex than simple shunt faults. One type of complex fault is an open phase condition that can result from a fallen conductor or failure of a breaker pole. In the former case, the condition is often accompanied by a fault detectable with normal relaying. In the latter case, the condition may be undetected by standard line relaying. The effect on a generator is dependent on the location of the open phase and the load level. If an open phase occurs between the generator terminals and the high-voltage side of the GSU in the switchyard, and the generator is at full load, damaging negative sequence current can be generated. However, for the same operating condition, an open conductor at the incoming transmission lines located in the switchyard can result in minimal negative sequence current. In 2012, a nuclear power generating station (NPGS) suffered series or open phase fault due to insulator mechanical failure in the 345 kV switchyard. This resulted in both reactor units tripping offline in two separate incidents. Series fault on one of the phases resulted in voltage imbalance that was not detected by the degraded voltage relays. These under-voltage relays did not initiate a start signal to the emergency diesel generators (EDG) because they sensed adequate voltage on the remaining phases exposing a design vulnerability. This paper is intended to help protection engineers calculate complex circuit faults like open phase condition using computer program. The impact of this type of

  11. Experiment data report for LOFT Boron dilution Experiment L6-6

    International Nuclear Information System (INIS)

    Stitt, B.D.; Divine, J.M.

    1982-06-01

    Selected pertinent and uninterpreted data from the sixth anticipated transient experiment (Experiment L6-6) conducted in the Loss-of-Fluid Test (LOFT) facility are presented. Experiment L6-6 simulated a boron dilution accident by injecting demineralized water into the primary coolant system (PCS) at a rate of 0.47 L/s while the reactor was in a cold shutdown condition with the control rods withdrawn. System pressure was maintained at approximately 285 kPa throughout the experiment. The experiment was divided into two parts. In the first part, L6-6A, a recirculation flow of 4.7 L/s was maintained through the PCS and criticality was achieved 7416 +- 10 s after the initiation of the dilution flow. The second part, L6-6B, was identical to L6-6A except that a recirculation flow of 9.5 L/s was maintained and criticality occurred at 8058 +- 10 s

  12. Testing and design of a passive container for the optimisation of highbush blueberries (Vaccinium corymbosum L. cold chain

    Directory of Open Access Journals (Sweden)

    Roberto Beghi

    2016-06-01

    Full Text Available The aim of this work is to test a passive cooling system (PCS on highbush blueberry (Vaccinium corymbosum L. to verify cooling performances soon after harvest. Based on experimental results the cooling trend was modelled and a dedicated system was designed for the optimisation of blueberries cold chain. The evolution of qualitative characteristics of stored fruits was evaluated analysing the percentage of damaged berries, the weight loss, the texture, the titratable acidity and the total soluble solids content. The analysis of temperature profiles during transport using PCS shows how this device is not fast enough in tearing down the blueberries field heat. A computer simulation, using finite elements method modelling, considering the thermo-physical properties of materials used and the boundary conditions arising from experimental data collected was carried out. Computer modelling has provided the characteristics of geometry, thickness, type and density of the material to obtain the desired cooling performance.

  13. Aircraft Abnormal Conditions Detection, Identification, and Evaluation Using Innate and Adaptive Immune Systems Interaction

    Science.gov (United States)

    Al Azzawi, Dia

    Abnormal flight conditions play a major role in aircraft accidents frequently causing loss of control. To ensure aircraft operation safety in all situations, intelligent system monitoring and adaptation must rely on accurately detecting the presence of abnormal conditions as soon as they take place, identifying their root cause(s), estimating their nature and severity, and predicting their impact on the flight envelope. Due to the complexity and multidimensionality of the aircraft system under abnormal conditions, these requirements are extremely difficult to satisfy using existing analytical and/or statistical approaches. Moreover, current methodologies have addressed only isolated classes of abnormal conditions and a reduced number of aircraft dynamic parameters within a limited region of the flight envelope. This research effort aims at developing an integrated and comprehensive framework for the aircraft abnormal conditions detection, identification, and evaluation based on the artificial immune systems paradigm, which has the capability to address the complexity and multidimensionality issues related to aircraft systems. Within the proposed framework, a novel algorithm was developed for the abnormal conditions detection problem and extended to the abnormal conditions identification and evaluation. The algorithm and its extensions were inspired from the functionality of the biological dendritic cells (an important part of the innate immune system) and their interaction with the different components of the adaptive immune system. Immunity-based methodologies for re-assessing the flight envelope at post-failure and predicting the impact of the abnormal conditions on the performance and handling qualities are also proposed and investigated in this study. The generality of the approach makes it applicable to any system. Data for artificial immune system development were collected from flight tests of a supersonic research aircraft within a motion-based flight

  14. Medical Signal-Conditioning and Data-Interface System

    Science.gov (United States)

    Braun, Jeffrey; Jacobus, charles; Booth, Scott; Suarez, Michael; Smith, Derek; Hartnagle, Jeffrey; LePrell, Glenn

    2006-01-01

    A general-purpose portable, wearable electronic signal-conditioning and data-interface system is being developed for medical applications. The system can acquire multiple physiological signals (e.g., electrocardiographic, electroencephalographic, and electromyographic signals) from sensors on the wearer s body, digitize those signals that are received in analog form, preprocess the resulting data, and transmit the data to one or more remote location(s) via a radiocommunication link and/or the Internet. The system includes a computer running data-object-oriented software that can be programmed to configure the system to accept almost any analog or digital input signals from medical devices. The computing hardware and software implement a general-purpose data-routing-and-encapsulation architecture that supports tagging of input data and routing the data in a standardized way through the Internet and other modern packet-switching networks to one or more computer(s) for review by physicians. The architecture supports multiple-site buffering of data for redundancy and reliability, and supports both real-time and slower-than-real-time collection, routing, and viewing of signal data. Routing and viewing stations support insertion of automated analysis routines to aid in encoding, analysis, viewing, and diagnosis.

  15. A bottom-up approach to automatically configured Tango control systems

    International Nuclear Information System (INIS)

    Rubio-Manrique, S.; Beltran, D.; Costa, I.; Fernandez-Carreiras, D.; Gigante, J.V.; Klora, J.; Matilla, O.; Ranz, R.; Ribas, J.; Sanchez, O.

    2012-01-01

    Alba is the first synchrotron light source built in Spain. Most of Alba control system has been developed on top of Tango control system. An amount of 5531 devices are controlled in Alba accelerators (linac, booster and storage ring) using 150 Linux PCs. Alba maintains a central repository, so called 'Cabling and Controls database' (CCDB), which keeps the inventory of equipment, cables, connections and their configuration and technical specifications. The valuable information kept in this MySQL database enables some tools to automatically create and configure Tango devices and other software components of the control systems of Accelerators, beamlines and laboratories. This paper describes the process involved in this automatic setup

  16. Equipment Qualification and Environment Establishment for COTS Dedication of Safety Grade PC

    International Nuclear Information System (INIS)

    Ahn, Kwang Chul; Bin, Chang Sun; Kwon, Yoon Kwang; Kang, Shin Woo; Koh, Sung Won; Shon, Eui Chan; Jang, Hyun Doo; Song, Il Sup; Lee, Hyun Noh

    2010-08-01

    Safety grade PCs are required for protection systems of SKN 3 and 4 nuclear power plant and subsequent plants. Commercial grade item (CGI) dedication should be carried out to utilize a commercial PC as a safety grade PC of nuclear power plants. This project is aimed to perform the equipment qualification of the commercial PC, and review and improve the quality system of the PC supplier. As a result of the EQ for the CGI dedication, selected military PCs have passed the environment test, the seismic test, and the EMI test required for the digital controllers of nuclear plants. In addition, a walk-through of the quality system of the PC supplier, ISO 9001, was carried out and the quality system was improved. History data for the PC was gathered. As the analysis of the history data showed that operating experience time of the PC is longer than the plant life time, the history data could be used as an evidence of acceptance. After dedicated according to the CGI dedication process, military rugged PCs could be used for safety grade PCs

  17. Artificial intelligence tools decision support systems in condition monitoring and diagnosis

    CERN Document Server

    Galar Pascual, Diego

    2015-01-01

    Artificial Intelligence Tools: Decision Support Systems in Condition Monitoring and Diagnosis discusses various white- and black-box approaches to fault diagnosis in condition monitoring (CM). This indispensable resource: Addresses nearest-neighbor-based, clustering-based, statistical, and information theory-based techniques Considers the merits of each technique as well as the issues associated with real-life application Covers classification methods, from neural networks to Bayesian and support vector machines Proposes fuzzy logic to explain the uncertainties associated with diagnostic processes Provides data sets, sample signals, and MATLAB® code for algorithm testing Artificial Intelligence Tools: Decision Support Systems in Condition Monitoring and Diagnosis delivers a thorough evaluation of the latest AI tools for CM, describing the most common fault diagnosis techniques used and the data acquired when these techniques are applied.

  18. High Power laser power conditioning system new discharge circuit research

    CERN Document Server

    Li Yi; Peng Han Sheng; Zhou Pei Zhang; Zheng Wan Guo; Guo Lang Fu; Chen Li Hua; Chen De Hui; Lai Gui You; Luan Yong Ping

    2002-01-01

    The new discharge circuit of power conditioning system for high power laser is studied. The theoretical model of the main discharge circuit is established. The pre-ionization circuit is studied in experiment. In addition, the explosion energy of the new large xenon lamp is successfully measured. The conclusion has been applied to 4 x 2 amplifier system

  19. Experimental performance study of a proposed desiccant based air conditioning system.

    Science.gov (United States)

    Bassuoni, M M

    2014-01-01

    An experimental investigation on the performance of a proposed hybrid desiccant based air conditioning system referred as HDBAC is introduced in this paper. HDBAC is mainly consisted of a liquid desiccant dehumidification unit integrated with a vapor compression system (VCS). The VCS unit has a cooling capacity of 5.27 kW and uses 134a as refrigerant. Calcium chloride (CaCl2) solution is used as the working desiccant material. HDBAC system is used to serve low sensible heat factor applications. The effect of different parameters such as, process air flow rate, desiccant solution flow rate, evaporator box and condenser box solution temperatures, strong solution concentration and regeneration temperature on the performance of the system is studied. The performance of the system is evaluated using some parameters such as: the coefficient of performance (COPa), specific moisture removal and energy saving percentage. A remarkable increase of about 54% in the coefficient of performance of the proposed system over VCS with reheat is achieved. A maximum overall energy saving of about 46% is observed which emphasizes the use of the proposed system as an energy efficient air conditioning system.

  20. Physiological and subjective responses in the elderly when using floor heating and air conditioning systems.

    Science.gov (United States)

    Hashiguchi, Nobuko; Tochihara, Yutaka; Ohnaka, Tadakatsu; Tsuchida, Chiaki; Otsuki, Tamio

    2004-11-01

    The purpose of this study was to investigate the effects of a floor heating and air conditioning system on thermal responses of the elderly. Eight elderly men and eight university students sat for 90 minutes in a chair under the following 3 conditions: air conditioning system (A), floor heating system (F) and no heating system (C). The air temperature of sitting head height for condition A was 25 degrees C, and the maximum difference in vertical air temperature was 4 degrees C. The air and floor temperature for condition F were 21 and 29 degrees C, respectively. The air temperature for condition C was 15 degrees C. There were no significant differences in rectal temperature and mean skin temperature between condition A and F. Systolic blood pressure of the elderly men in condition C significantly increased compared to those in condition A and F. No significant differences in systolic blood pressure between condition A and F were found. The percentage of subjects who felt comfortable under condition F was higher than that of those under condition A in both age groups, though the differences between condition F and A was not significant. Relationships between thermal comfort and peripheral (e.g., instep, calf, hand) skin temperature, and the relationship between thermal comfort and leg thermal sensation were significant for both age groups. However, the back and chest skin temperature and back thermal sensation for the elderly, in contrast to that for the young, was not significantly related to thermal comfort. These findings suggested that thermal responses and physiological strain using the floor heating system did not significantly differ from that using the air conditioning system, regardless of the subject age and despite the fact that the air temperature with the floor heating system was lower. An increase in BP for elderly was observed under the condition in which the air temperature was 15 degrees C, and it was suggested that it was necessary for the elderly

  1. Calibrated photostimulated luminescence is an effective approach to identify irradiated orange during storage

    International Nuclear Information System (INIS)

    Jo, Yunhee; Sanyal, Bhaskar; Chung, Namhyeok; Lee, Hyun-Gyu; Park, Yunji; Park, Hae-Jun; Kwon, Joong-Ho

    2015-01-01

    Photostimulated luminescence (PSL) has been employed as a fast screening method for various irradiated foods. In this study the potential use of PSL was evaluated to identify oranges irradiated with gamma ray, electron beam and X-ray (0–2 kGy) and stored under different conditions for 6 weeks. The effects of light conditions (natural light, artificial light, and dark) and storage temperatures (4 and 20 °C) on PSL photon counts (PCs) during post-irradiation periods were studied. Non-irradiated samples always showed negative values of PCs, while irradiated oranges exhibited intermediate results after first PSL measurements. However, the irradiated samples had much higher PCs. The PCs of all the samples declined as the storage time increased. Calibrated second PSL measurements showed PSL ratio <10 for the irradiated samples after 3 weeks of irradiation confirming their irradiation status in all the storage conditions. Calibrated PSL and sample storage in dark at 4 °C were found out to be most suitable approaches to identify irradiated oranges during storage. - Highlights: • Photostimulatedluminescence (PSL) was studied to identify irradiated orange for quarantine application. • PSL detection efficiency was compared amonggamma,electron, and X irradiation during shelf-life of oranges • PSL properties of samples were characterized by standard samples • Calibrated PSL gave a clear verdict on irradiation extending potential of PSL technique

  2. Changes in working conditions and physical health functioning among midlife and ageing employees.

    Science.gov (United States)

    Mänty, Minna; Kouvonen, Anne; Lallukka, Tea; Lahti, Jouni; Lahelma, Eero; Rahkonen, Ossi

    2015-11-01

    The aim this study was to examine the effect of changes in physical and psychosocial working conditions on physical health functioning among ageing municipal employees. Follow-up survey data were collected from midlife employees of the City of Helsinki, Finland, at three time points: wave 1 (2000-2002), wave 2 (2007), and wave 3 (2012). Changes in physical and psychosocial working conditions were assessed between waves 1 and 2. Physical health functioning was measured by the physical component summary (PCS) of the Short-Form 36 questionnaire at each of the three waves. In total, 2784 respondents (83% women) who remained employed over the follow-up were available for the analyses. Linear mixed-effect models were used to assess the associations and adjust for key covariates (age, gender, obesity, chronic diseases, and health behaviors). Repeated and increased exposure to adverse physical working conditions was associated with greater decline in physical health functioning over time. In contrast, decrease in exposures reduced the decline. Of the psychosocial working conditions, changes in job demands had no effects on physical health functioning. However, decreased job control was associated with greater decline and repeated high or increased job control reduced the decline in physical health functioning over time. Adverse changes in physical working conditions and job control were associated with greater decline in physical health functioning over time, whereas favorable changes in these exposures reduced the decline. Preventing deterioration and promoting improvement of working conditions are likely to help maintain better physical health functioning among ageing employees.

  3. Study of Noise Canceling Performance of Feedforward Fuzzy-Based ANC System under Non-Causal Condition

    DEFF Research Database (Denmark)

    Mojallali, Hamed; Izadi-Zamanabadi, Roozbeh; Amini, Rouzbeh

    of noise canceling performance of feed-forward fuzzy-based ANC systems for ducts under non-causal condition is presented. For this purpose, we use fuzzy filtered-x algorithm as an adaptive filter and the results are compared with classical filteredx algorithm which is employed under the same conditions......Feed-forward active noise control (ANC) systems act as adaptive systems to control and cancel undesired signals and noises. If the delay in the noise canceling subsystems increases more than the delays in the primary path, non-causal condition will occur in these systems. In this paper, study....... Analysis shows that ANC systems using fuzzy algorithm has better efficiency for noise cancellation in non-causal condition....

  4. Groundwater detection monitoring system design under conditions of uncertainty

    NARCIS (Netherlands)

    Yenigül, N.B.

    2006-01-01

    Landfills represent a wide-spread and significant threat to groundwater quality. In this thesis a methodology was developed for the design of optimal groundwater moni-toring system design at landfill sites under conditions of uncertainty. First a decision analysis approach was presented for optimal

  5. Improvement of optical imaging resolution by a negative refraction photonic crystal with a solid immersion lens

    International Nuclear Information System (INIS)

    Tseng, M.-C.; Chen, L.-W.; Liu, C.-Y.

    2008-01-01

    Photonic crystals (PCs) have many potential applications because of their ability to control light-wave propagation. We have investigated the solid immersion lens (SIL) technology in imaging system based on negative refraction PCs and analyzed the influence of refractive index and geometric parameters of SIL on imaging resolution. In the finite element method calculation, the resolution of our optical system has improved greatly. The high performance of imaging resolution was achieved with shorter radius and larger refractive index of SIL. Furthermore, the effects of the three kinds of SILs at the same radius were analyzed. Such a mechanism of negative refraction PCs and SILs should open up a new application for designing components in optical imaging systems

  6. Parametric analysis of a combined dew point evaporative-vapour compression based air conditioning system

    Directory of Open Access Journals (Sweden)

    Shailendra Singh Chauhan

    2016-09-01

    Full Text Available A dew point evaporative-vapour compression based combined air conditioning system for providing good human comfort conditions at a low cost has been proposed in this paper. The proposed system has been parametrically analysed for a wide range of ambient temperatures and specific humidity under some reasonable assumptions. The proposed system has also been compared from the conventional vapour compression air conditioner on the basis of cooling load on the cooling coil working on 100% fresh air assumption. The saving of cooling load on the coil was found to be maximum with a value of 60.93% at 46 °C and 6 g/kg specific humidity, while it was negative for very high humidity of ambient air, which indicates that proposed system is applicable for dry and moderate humid conditions but not for very humid conditions. The system is working well with an average net monthly power saving of 192.31 kW h for hot and dry conditions and 124.38 kW h for hot and moderate humid conditions. Therefore it could be a better alternative for dry and moderate humid climate with a payback period of 7.2 years.

  7. Potential electricity savings by variable speed control of compressor for air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Nasution, Henry [Bung Hatta University, Department of Mechanical Engineering, Faculty of Industrial Engineering, Padang, West Sumatera (Indonesia); Wan Hassan, Mat Nawi [Universiti Teknologi Malaysia, Faculty of Mechanical Engineering, Skudai, Johor Bahru-Darul Ta' zim (Malaysia)

    2006-05-15

    The potential of a variable-speed compressor running on a controller to provide enhanced load-matching capability, energy saving and thermal comfort for application in air-conditioning system is demonstrated. An air-conditioning system, originally operated on a constant speed mode, is retrofitted with an inverter and a PID controller. The system was installed to a thermal environmental room together with a data acquisition system to monitor energy consumption and temperature of the room. Measurements were taken 2 h daily at a time interval of 5 min for an on/off and an inverter variable-speed conditions. The results indicate that thermal comfort of the room together with energy saving can be obtained through a proper selection of K for the controller. At a temperature setting of 22 C, the energy saving for the system is estimated to reach 25.3% for PID controllers. (orig.)

  8. 30 CFR 260.111 - What conditions apply to the bidding systems that MMS uses?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What conditions apply to the bidding systems that MMS uses? 260.111 Section 260.111 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE... What conditions apply to the bidding systems that MMS uses? (a) For each of the bidding systems in...

  9. Ventilation and air conditioning system in waste treatment and storage facilities

    International Nuclear Information System (INIS)

    Kinoshita, Hirotsugu; Sugawara, Kazushige.

    1987-01-01

    So far, the measures concerning the facilities for treating and storing radioactive wastes in nuclear fuel cycle in Japan were in the state which cannot be said to be sufficient. In order to cope with this situation, electric power companies constructed and operated radioactive waste concentration and volume reduction facilities, solid waste storing facilities for drums, high level solid waste storing facilities, spent fuel cask preserving facilities and so on successively in the premises of nuclear power stations, and for the wastes expected in future, the research and the construction plan of the facilities for treating and storing low, medium and high level wastes have been advanced. The ventilation and air conditioning system for these facilities is the important auxiliary system which has the mission of maintaining safe and pleasant environment in the facilities and lowering as far as possible the release of radioactive substances to outside. The outline of waste treatment and storage facilities is explained. The design condition, ventilation and air conditioning method, the features of respective waste treatment and storage facilities, and the problems for the future are described. Hereafter, mechanical ventilation system continues to be the main system, and filters become waste, while the exchange of filters is accompanied by the radiation exposure of workers. (Kako, I.)

  10. The Architecture of the CMS Level-1 Trigger Control and Monitoring System

    CERN Document Server

    Magrans de Abril, Marc; Hammer, Josef; Hartl, Christian; Xie, Zhen

    2011-01-01

    The architecture of the Level-1 Trigger Control and Monitoring system for the CMS experiment is presented. This system has been installed and commissioned on the trigger online computers and is currently used for data taking at the LHC. This is a medium-size distributed system that runs over 40 PCs and 200 processes that control about 4000 electronic boards. It has been designed to handle the trigger configuration and monitoring during data taking as well as all communications with the main run control of CMS. Furthermore its design has foreseen the provision of the software infrastructure for detailed testing of the trigger system during beam down time.

  11. Liquid over-feeding air conditioning system and method

    Science.gov (United States)

    Mei, V.C.; Chen, F.C.

    1993-09-21

    A refrigeration air conditioning system utilizing a liquid over-feeding operation is described. A liquid refrigerant accumulator-heat exchanger is placed in the system to provide a heat exchange relationship between hot liquid refrigerant discharged from condenser and a relatively cool mixture of liquid and vaporous refrigerant discharged from the evaporator. This heat exchange relationship substantially sub-cools the hot liquid refrigerant which undergoes little or no evaporation across the expansion device and provides a liquid over-feeding operation through the evaporator for effectively using 100 percent of evaporator for cooling purposes and for providing the aforementioned mixture of liquid and vaporous refrigerant. 1 figure.

  12. Simulation of Artificial Intelligence for Automotive Air-conditioning System

    Institute of Scientific and Technical Information of China (English)

    YUAN Xiao-mei; CHEN You-hua; CHEN Zhi-jiu

    2002-01-01

    The artificial intelligence is applied to the simulation of the automotive air-conditioning system ( AACS )According to the system's characteristics a model of AACS, based on neural network, is developed. Different control methods of AACS are discussed through simulation based on this model. The result shows that the neural- fuzzy control is the best one compared with the on-off control and conventional fuzzy control method.It can make the compartment's temperature descend rapidly to the designed temperature and the fluctuation is small.

  13. Fuzzy Based Decision Support System for Condition Assessment and Rating of Bridges

    Science.gov (United States)

    Srinivas, Voggu; Sasmal, Saptarshi; Karusala, Ramanjaneyulu

    2016-09-01

    In this work, a knowledge based decision support system has been developed to efficiently handle the issues such as distress diagnosis, assessment of damages and condition rating of existing bridges towards developing an exclusive and robust Bridge Management System (BMS) for sustainable bridges. The Knowledge Based Expert System (KBES) diagnoses the distresses and finds the cause of distress in the bridge by processing the data which are heuristic and combined with site inspection results, laboratory test results etc. The coupling of symbolic and numeric type of data has been successfully implemented in the expert system to strengthen its decision making process. Finally, the condition rating of the bridge is carried out using the assessment results obtained from the KBES and the information received from the bridge inspector. A systematic procedure has been developed using fuzzy mathematics for condition rating of bridges by combining the fuzzy weighted average and resolution identity technique. The proposed methodologies and the decision support system will facilitate in developing a robust and exclusive BMS for a network of bridges across the country and allow the bridge engineers and decision makers to carry out maintenance of bridges in a rational and systematic way.

  14. In situ conditioning for proton storage ring vacuum systems

    International Nuclear Information System (INIS)

    Blechschmidt, D.

    1978-01-01

    Average pressure and vacuum-stability limit as expected in the presence of a proton beam were measured after in situ treatments such as bakeout under various conditions, argon glow-discharge cleaning and sputter deposition of titanium. Measurements were carried out for test pipes made of stainless steel (untreated, electropolished, or cooled to 77 K), pure titanium and aluminum alloy. The measurement method used to obtain the vacuum-stability limit in the laboratory and in a prototype system is described. The results can be applied also to other systems of different geometry by use of scaling laws. In situ conditioning generally has a stronger influence on vacuum performance than a particular choice of material. Bakeout gives low average pressures and rather good vacuum stability. Glow discharges also increase the vacuum stability but have only a small effect on the static pressure. Coating the beam-pipe wall with titanium by in situ sputtering provides large linear pumping, thus a lower pressure and an extremely good vacuum stability

  15. The Burden of Peristomal Skin Complications on an Ostomy Population as Assessed by Health Utility and the Physical Component Summary of the SF-36v2®.

    Science.gov (United States)

    Nichols, Thom R; Inglese, Gary W

    2018-01-01

    Body-altering surgery may affect perceptions of one's self. For those with abdominal stoma surgeries, altered perceptions amplified by peristomal skin condition can increase health burdens. To assess health utility and health-related quality of life in an adult US ostomy sample in the presence of three levels of peristomal skin condition: intact, moderately compromised, and severely compromised. The short form 36 health survey version 2, a generic health survey incorporating the six-dimensional health state short form preference-based utility index, was chosen to assess the sample. Analysis of covariance adjusted for age and time from surgery was used. The six-dimensional health state short form utilities for those with intact skin and physical component summary (PCS) levels indicating no physical limitations varied significantly from those with severely compromised skin and indicating the greatest degree of physical limitation (0.833 vs. 0.527). Peristomal skin condition decreases were associated with health utility decreases across all levels of the PCS. Because peristomal skin conditions are intermittent, the analysis presents quality-adjusted life-days (QALDs) per month. Ostomates with intact skin and PCS levels indicating no physical limitations demonstrated significant differences from those with severe skin condition and indicating the greatest degree of physical limitations (26.5 d/mo vs. 15.8 d/mo). As peristomal skin condition worsened, QALDs decreased across all levels of the PCS. A minimally important expected value of health was estimated to be an increase of 2.18 QALDs/mo. Successful treatment from a clinical perspective is more than the elimination of conditions-it is also a return of quality time to an individual. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  16. Criteria for evaluating the condition of a tropical cyclone warning system.

    Science.gov (United States)

    Parker, D

    1999-09-01

    This paper evaluates the condition (i.e. health) of a tropical cyclone warning system (TCWS) during a 'quiet period' between infrequent intense cyclones. Capacity to make pre-disaster evaluations is important--disaster warning systems need to be in sound condition before, not after, disaster. The research--part of the UK's International Decade of Natural Disaster Reduction Flagship Programme--focuses upon an evaluatory method first used on flood warning systems. The Criteria-development Matrix comprises social, organisational and institutional criteria by which a TCWS may be assessed using a five-stage development scale. This method is used to evaluate Mauritius's TCWS using in-depth interview data. Ways to enhance the method and apply it to other disaster warning systems are discussed. The TCWS in Mauritius is a relatively sound one from which others can learn. Weaknesses requiring attention for Mauritius's TCWS to progress to an advanced level of development are identified.

  17. Fault diagnosis of air conditioning systems based on qualitative bond graph

    International Nuclear Information System (INIS)

    Ghiaus, C.

    1999-01-01

    The bond graph method represents a unified approach for modeling engineering systems. The main idea is that power transfer bonds the components of a system. The bond graph model is the same for both quantitative representation, in which parameters have numerical values, and qualitative approach, in which they are classified qualitatively. To infer the cause of faults using a qualitative method, a system of qualitative equations must be solved. However, the characteristics of qualitative operators require specific methods for solving systems of equations having qualitative variables. This paper proposes both a method for recursively solving the qualitative system of equations derived from bond graph, and a bond graph model of a direct-expansion, mechanical vapor-compression air conditioning system. Results from diagnosing two faults in a real air conditioning system are presented and discussed. Occasionally, more than one fault candidate is inferred for the same set of qualitative values derived from measurements. In these cases, additional information is required to localize the fault. Fault diagnosis is initiated by a fault detection mechanism which also classifies the quantitative measurements into qualitative values; the fault detection is not presented here. (author)

  18. Probabilistic-numerical assessment of pyroclastic current hazard at Campi Flegrei and Naples city: Multi-VEI scenarios as a tool for "full-scale" risk management.

    Science.gov (United States)

    Mastrolorenzo, Giuseppe; Palladino, Danilo M; Pappalardo, Lucia; Rossano, Sergio

    2017-01-01

    The Campi Flegrei volcanic field (Italy) poses very high risk to the highly urbanized Neapolitan area. Eruptive history was dominated by explosive activity producing pyroclastic currents (hereon PCs; acronym for Pyroclastic Currents) ranging in scale from localized base surges to regional flows. Here we apply probabilistic numerical simulation approaches to produce PC hazard maps, based on a comprehensive spectrum of flow properties and vent locations. These maps are incorporated in a Geographic Information System (GIS) and provide all probable Volcanic Explosivity Index (VEI) scenarios from different source vents in the caldera, relevant for risk management planning. For each VEI scenario, we report the conditional probability for PCs (i.e., the probability for a given area to be affected by the passage of PCs in case of a PC-forming explosive event) and related dynamic pressure. Model results indicate that PCs from VEIextreme event) would affect a large part of the Campanian Plain to the north and the city of Naples to the east. Thus, in case of renewal of eruptive activity at Campi Flegrei, up to 3 million people will be potentially exposed to volcanic hazard, pointing out the urgency of an emergency plan. Considering the present level of uncertainty in forecasting the future eruption type, size and location (essentially based on statistical analysis of previous activity), we suggest that appropriate planning measures should face at least the VEI 5 reference scenario (at least 2 occurrences documented in the last 10 ka).

  19. Designing the lithium bromide air conditioning absorption system for a bus

    International Nuclear Information System (INIS)

    Yusoff Ali; Kamaruzzaman Sopian; Hariadi

    2006-01-01

    A system of air-conditioning using Lithium Bromide absorption system is used as an alternative refrigerant that will not pollute the atmosphere. Lithium Bromide is a chemical salt soluble in water. There is a big difference between vapour compression system and LiBr 2 absorption system. The absorption air conditioning system is made of a generator, a condenser, an evaporator and an absorber with necessary pumps and piping. When LiBr 2 solution is heated under low pressure, water will evaporate first, while LiBr 2 will remain in the solution and will become more concentrated. The water is the refrigerant in this system. The generator, where the water is vapourised, is heated using an electric heater or solar energy. The LiBr 2 weak solution under low pressure in the generator is heated and the water evaporate into vapour. The vapour produced is then cooled in the condenser and then expanded into the evaporator. The refrigerant (water) in evaporator change phase from liquid to vapour by absorbing heat from cooling water, which flow in the coil in the evaporator. The chilled water obtained is then pumped into the fan coil, which will be used in conditioning the passenger area of the bus. The water vapour from the evaporator is absorbed into LiBr 2 solution in the absorber, forming a weak solution of LiBr 2 . the weak solution from the absorber is then pumped back to the generator to regenerate. The absorption system does not use compressor, but requires pumps that need lower input power compared to that of a compressor. The system is considered as a new application for the bus. This will have great potential and will be environmentally friendly. The model in this study will be used for calculation of the cooling load for the bus

  20. Real-time data acquisition and feedback control using Linux Intel computers

    International Nuclear Information System (INIS)

    Penaflor, B.G.; Ferron, J.R.; Piglowski, D.A.; Johnson, R.D.; Walker, M.L.

    2006-01-01

    This paper describes the experiences of the DIII-D programming staff in adapting Linux based Intel computing hardware for use in real-time data acquisition and feedback control systems. Due to the highly dynamic and unstable nature of magnetically confined plasmas in tokamak fusion experiments, real-time data acquisition and feedback control systems are in routine use with all major tokamaks. At DIII-D, plasmas are created and sustained using a real-time application known as the digital plasma control system (PCS). During each experiment, the PCS periodically samples data from hundreds of diagnostic signals and provides these data to control algorithms implemented in software. These algorithms compute the necessary commands to send to various actuators that affect plasma performance. The PCS consists of a group of rack mounted Intel Xeon computer systems running an in-house customized version of the Linux operating system tailored specifically to meet the real-time performance needs of the plasma experiments. This paper provides a more detailed description of the real-time computing hardware and custom developed software, including recent work to utilize dual Intel Xeon equipped computers within the PCS

  1. Probabilistic-numerical assessment of pyroclastic current hazard at Campi Flegrei and Naples city: Multi-VEI scenarios as a tool for "full-scale" risk management.

    Directory of Open Access Journals (Sweden)

    Giuseppe Mastrolorenzo

    Full Text Available The Campi Flegrei volcanic field (Italy poses very high risk to the highly urbanized Neapolitan area. Eruptive history was dominated by explosive activity producing pyroclastic currents (hereon PCs; acronym for Pyroclastic Currents ranging in scale from localized base surges to regional flows. Here we apply probabilistic numerical simulation approaches to produce PC hazard maps, based on a comprehensive spectrum of flow properties and vent locations. These maps are incorporated in a Geographic Information System (GIS and provide all probable Volcanic Explosivity Index (VEI scenarios from different source vents in the caldera, relevant for risk management planning. For each VEI scenario, we report the conditional probability for PCs (i.e., the probability for a given area to be affected by the passage of PCs in case of a PC-forming explosive event and related dynamic pressure. Model results indicate that PCs from VEI<4 events would be confined within the Campi Flegrei caldera, PC propagation being impeded by the northern and eastern caldera walls. Conversely, PCs from VEI 4-5 events could invade a wide area beyond the northern caldera rim, as well as part of the Naples metropolitan area to the east. A major controlling factor of PC dispersal is represented by the location of the vent area. PCs from the potentially largest eruption scenarios (analogous to the ~15 ka, VEI 6 Neapolitan Yellow Tuff or even the ~39 ka, VEI 7 Campanian Ignimbrite extreme event would affect a large part of the Campanian Plain to the north and the city of Naples to the east. Thus, in case of renewal of eruptive activity at Campi Flegrei, up to 3 million people will be potentially exposed to volcanic hazard, pointing out the urgency of an emergency plan. Considering the present level of uncertainty in forecasting the future eruption type, size and location (essentially based on statistical analysis of previous activity, we suggest that appropriate planning measures should

  2. Work with Apple's Rhapsody Operating System which Allows Simultaneous UNIX Program Development, UNIX Program Execution, and PC Application Execution

    OpenAIRE

    Summers, Don; Riley, Chris; Cremaldi, Lucien; Sanders, David

    2001-01-01

    Over the past decade, UNIX workstations have provided a very powerful program development environment. However, workstations are more expensive than PCs and Macintoshes and require a system manager for day-to-day tasks such as disk backup, adding users, and setting up print queues. Native commercial software for system maintenance and "PC applications" has been lacking under UNIX. Apple's new Rhapsody operating system puts the current MacOS on a NeXT UNIX foundation and adds an enhanced NeXTS...

  3. Dynamische Programm-Code-Verwaltung und -Optimierung für eingebettete Systeme

    OpenAIRE

    Schell, Dominic

    2009-01-01

    Bei Desktop-PCs ist ein großer Hauptspeicherausbau im Bereich jenseits von 1 GB dank gesunkener Speicherpreise und auf Grund gestiegener Anforderungen keine Seltenheit mehr. Es existiert jedoch eine Unmenge Kleinstrechner, wie z.B. im Automobilbereich eingesetzte Steuergeräte, die sich einen großen Speicherausbau wegen des Platzbedarfs der Speicherchips, deren Energiekonsum und den zusätzlichen Kosten nicht leisten können. Ein wichtiges Ziel beim Erzeugen der Software für eingebettete Systeme...

  4. IVVS actuating system compatibility test to ITER gamma radiation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Paolo, E-mail: paolo.rossi@enea.it [Associazione EURATOM-ENEA sulla Fusione, 45 Via Enrico Fermi, 00044 Frascati, Rome (Italy); Collibus, M. Ferri de; Florean, M.; Monti, C.; Mugnaini, G.; Neri, C.; Pillon, M.; Pollastrone, F. [Associazione EURATOM-ENEA sulla Fusione, 45 Via Enrico Fermi, 00044 Frascati, Rome (Italy); Baccaro, S.; Piegari, A. [ENEA CR Casaccia, 301 Via Anguillarese, 00123 Santa Maria di Galeria, Rome (Italy); Damiani, C.; Dubus, G. [Fusion For Energy c/Josep Pla, n° 2 Torres Diagonal Litoral, 08019 Barcelona (Spain)

    2013-10-15

    Highlights: • ENEA developed and tested a prototype of a laser In Vessel Viewing and ranging System (IVVS) for ITER. • One piezo-motor prototype has been tested on the ENEA Calliope gamma irradiation facility to verify its compatibility to ITER gamma radiation conditions. • After a total dose of more than 4 MGy the piezo-motor maintained almost the same working parameters monitored before test without any evident and significant degradation of functionality. • After the full gamma irradiation test, the same piezo-motor assembly will be tested with 14 MeV neutrons irradiation using ENEA FNG facility. -- Abstract: The In Vessel Viewing System (IVVS) is a fundamental remote handling equipment, which will be used to make a survey of the status of the blanket first wall and divertor plasma facing components. A design and testing activity is ongoing, in the framework of a Fusion for Energy (F4E) grant agreement, to make the IVVS probe design compatible with ITER operating conditions and in particular, but not only, with attention to neutrons and gammas fluxes and both space constraints and interfaces. The paper describes the testing activity performed on the customized piezoelectric motors and the main components of the actuating system of the IVVS probe with reference to ITER gamma radiation conditions. In particular the test is performed on the piezoelectric motor, optical encoder and small scale optical samples .The test is carried out on the ENEA Calliope gamma irradiation facility at ITER relevant gamma fields at rate of about 2.5 kGy/h and doses of 4 MGy. The paper reports in detail the setup arrangement of the test campaign in order to verify significant working capability of the IVVS actuating components and the results are shown in terms of functional performances and parameters. The overall test campaign on IVVS actuating system will be completed on other ENEA testing facilities in order to verify compatibility to Magnetic field, neutrons and thermal

  5. IVVS actuating system compatibility test to ITER gamma radiation conditions

    International Nuclear Information System (INIS)

    Rossi, Paolo; Collibus, M. Ferri de; Florean, M.; Monti, C.; Mugnaini, G.; Neri, C.; Pillon, M.; Pollastrone, F.; Baccaro, S.; Piegari, A.; Damiani, C.; Dubus, G.

    2013-01-01

    Highlights: • ENEA developed and tested a prototype of a laser In Vessel Viewing and ranging System (IVVS) for ITER. • One piezo-motor prototype has been tested on the ENEA Calliope gamma irradiation facility to verify its compatibility to ITER gamma radiation conditions. • After a total dose of more than 4 MGy the piezo-motor maintained almost the same working parameters monitored before test without any evident and significant degradation of functionality. • After the full gamma irradiation test, the same piezo-motor assembly will be tested with 14 MeV neutrons irradiation using ENEA FNG facility. -- Abstract: The In Vessel Viewing System (IVVS) is a fundamental remote handling equipment, which will be used to make a survey of the status of the blanket first wall and divertor plasma facing components. A design and testing activity is ongoing, in the framework of a Fusion for Energy (F4E) grant agreement, to make the IVVS probe design compatible with ITER operating conditions and in particular, but not only, with attention to neutrons and gammas fluxes and both space constraints and interfaces. The paper describes the testing activity performed on the customized piezoelectric motors and the main components of the actuating system of the IVVS probe with reference to ITER gamma radiation conditions. In particular the test is performed on the piezoelectric motor, optical encoder and small scale optical samples .The test is carried out on the ENEA Calliope gamma irradiation facility at ITER relevant gamma fields at rate of about 2.5 kGy/h and doses of 4 MGy. The paper reports in detail the setup arrangement of the test campaign in order to verify significant working capability of the IVVS actuating components and the results are shown in terms of functional performances and parameters. The overall test campaign on IVVS actuating system will be completed on other ENEA testing facilities in order to verify compatibility to Magnetic field, neutrons and thermal

  6. Energy managemant through PCM based thermal storage system for building air-conditioning: Tidel Park, Chennai

    International Nuclear Information System (INIS)

    Nallusamy, N.; Sampath, S.; Velraj, R.

    2006-01-01

    Many modern building are designed for air-conditioning and the amount of electrical energy required for providing air-conditioning can be very significant especially in the tropics. Conservation of energy is major concern to improve the overall efficiency of the system. Integration is energy storage with the conventional system gives a lot of potential for energy saving and long-term economics. Thermal energy storage systems can improve energy management and help in matching supply and demand patterns. In the present work, a detailed study has been done on the existing thermal energy storage system used in the air-conditioning system in Tidel Park, Chennai. The present study focuses on the cool energy storage system. The modes of operation and advantages of such a system for energy management are highlighted. The reason for the adoption of combined storage system and the size of the storage medium in the air-conditioning plant are analyzed. The possibility of using this concept in other cooling and heating applications, such as storage type solar water heating system, has been explored

  7. Characterization of a thermoelectric cooler based thermal management system under different operating conditions

    International Nuclear Information System (INIS)

    Russel, M.K.; Ewing, D.; Ching, C.Y.

    2013-01-01

    The performance of a thermoelectric cooler (TEC) based thermal management system for an electronic packaging design that operates under a range of ambient conditions and system loads is examined using a standard model for the TEC and a thermal resistance network for the other components. Experiments were performed and it was found that the model predictions were in good agreement with the experimental results. An operating envelope is developed to characterize the TEC based thermal management system for peak and off peak operating conditions. Parametric studies were performed to analyze the effect of the number of TEC module(s) in the system, geometric factor of the thermo-elements and the cold to hot side thermal resistances on the system performance. The results showed that there is a tradeoff between the extent of off peak heat fluxes and ambient temperatures when the system can be operated at a low power penalty region and the maximum capacity of the system. - Highlights: ► A model was developed for thermal management systems using thermoelectric coolers. ► Model predictions were in good agreement with experimental results. ► An operating envelope was developed for peak and off peak conditions. ► The effect of the number of thermoelectric coolers on the system was determined.

  8. Research on ration selection of mixed absorbent solution for membrane air-conditioning system

    International Nuclear Information System (INIS)

    Li, Xiu-Wei; Zhang, Xiao-Song; Wang, Fang; Zhao, Xiao; Zhang, Zhuo

    2015-01-01

    Highlights: • We derive models of the membrane air-conditioning system with mixed absorbents. • We make analysis on system COP, cost-effectiveness and economy. • The paper provides a new method for ideal absorbent selection. • The solutes concentration of 50% achieves the best cost-effectiveness and the economy. - Abstract: Absorption air-conditioning system is a good alternative to vapor compression system for developing low carbon society. To improve the performance of the traditional absorption system, the membrane air-conditioning system is configured and its COP can reach as high as 6. Mixed absorbents are potential for cost reduction of the membrane system while maintaining a high COP. On the purpose of finding ideal mixed absorbent groups, this paper makes analysis on COP, cost-effectiveness and economy of the membrane system with mixed LiBr–CaCl 2 absorbent solution. The models of the system have been developed for the analysis. The results show the COP is higher for the absorbent groups with lower concentration of the total solute and higher concentration ratio of LiBr. It also reveals when the total solutes concentration is about 50%, it achieves the best cost-effectiveness and the economy. The process of the analysis provides a useful method for mixed absorbents selection

  9. Thermal Conditions in a Simulated Office Environment with Convective and Radiant Cooling Systems

    DEFF Research Database (Denmark)

    Mustakallio, Panu; Bolashikov, Zhecho Dimitrov; Kostov, Kalin

    2013-01-01

    velocity and turbulent intensity were measured and draft rate levels calculated in the room. Manikin-based equivalent temperature (MBET) was determined by two thermal manikins to identify the impact of the local thermal conditions generated by the studied systems on occupants’ thermal comfort. The results......The thermal conditions in a two person office room were measured with four air conditioning systems: chilled beam (CB), chilled beam with radiant panel (CBR), chilled ceiling with ceiling installed mixing ventilation (CCMV) and four desk partition mounted local radiant cooling panels with mixing...

  10. Thermodynamic analysis of an innovative liquid desiccant air conditioning system to supply potable water

    International Nuclear Information System (INIS)

    Ahmed, M.A.; Gandhidasan, P.; Zubair, Syed M.; Bahaidarah, Haitham M.

    2017-01-01

    Highlights: • The study objective is to reduce the energy consumption of desiccant AC system. • Heat and mass losses are recovered in the proposed system using a condenser. • The conventional and the proposed systems are compared in terms of COP. • The proposed system performance is better than the conventional system. • The proposed system produces freshwater in addition to space cooling. - Abstract: Liquid desiccant air conditioning systems are cost-effective, environmentally friendly and energy efficient techniques, especially in coastal areas. In the conventional liquid desiccant air conditioning system, the scavenging air is expelled into the atmosphere carrying a considerable amount of energy and water vapor. Thus, there is plenty of room to improve the system performance by recovering these losses. The proposed system consists of a conventional liquid desiccant air conditioning system plus a condenser. The aim of this study is to reduce the energy consumption by recovering the heat from the scavenging air using the condenser while also producing freshwater in addition to space cooling. Lithium chloride (LiCl) is used as the liquid desiccant for this study. The mathematical formulation for simultaneous heat and mass transfer between the condenser and the regenerator was developed to establish a comparison between the performance of the conventional and modified systems. Using the generated model, it is found that the modified system performance is 11.25% better than the conventional system and that it produces 86.4 kg of freshwater per hour as a by-product under the given conditions.

  11. An intelligent condition monitoring system for on-line classification of machine tool wear

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Fu; Hope, A D; Javed, M [Systems Engineering Faculty, Southampton Institute (United Kingdom)

    1998-12-31

    The development of intelligent tool condition monitoring systems is a necessary requirement for successful automation of manufacturing processes. This presentation introduces a tool wear monitoring system for milling operations. The system utilizes power, force, acoustic emission and vibration sensors to monitor tool condition comprehensively. Features relevant to tool wear are drawn from time and frequency domain signals and a fuzzy pattern recognition technique is applied to combine the multisensor information and provide reliable classification results of tool wear states. (orig.) 10 refs.

  12. An intelligent condition monitoring system for on-line classification of machine tool wear

    Energy Technology Data Exchange (ETDEWEB)

    Fu Pan; Hope, A.D.; Javed, M. [Systems Engineering Faculty, Southampton Institute (United Kingdom)

    1997-12-31

    The development of intelligent tool condition monitoring systems is a necessary requirement for successful automation of manufacturing processes. This presentation introduces a tool wear monitoring system for milling operations. The system utilizes power, force, acoustic emission and vibration sensors to monitor tool condition comprehensively. Features relevant to tool wear are drawn from time and frequency domain signals and a fuzzy pattern recognition technique is applied to combine the multisensor information and provide reliable classification results of tool wear states. (orig.) 10 refs.

  13. MATHEMATICAL MODEL FOR ESTIMATION OF MECHANICAL SYSTEM CONDITION IN DYNAMICS

    Directory of Open Access Journals (Sweden)

    D. N. Mironov

    2011-01-01

    Full Text Available The paper considers an estimation of a complicated mechanical system condition in dynamics with due account of material degradation and accumulation of micro-damages. An element of continuous medium has been simulated and described with the help of a discrete element. The paper contains description of a model for determination of mechanical system longevity in accordance with number of cycles and operational period.

  14. Commissioning of the Cryogenic System for the ATLAS Superconducting Magnets

    CERN Document Server

    Delruelle, N; Bradshaw, T; Haug, F; ten Kate, H H J; Passardi, Giorgio; Pengo, R; Pezzetti, M; Pirotte, O; Rochford, J

    2006-01-01

    The paper describes the test results of the helium cryoplant for the superconducting magnets of the ATLAS particle detector at CERN. It consists of two refrigerators used in common by all the magnets and of two proximity cryogenic systems (PCS) interfacing respectively the toroids and the central solenoid. Emphasis is given to the commissioning of the refrigerators: the main unit of 6 kW equivalent capacity at 4.5 K and the thermal shield refrigerator providing 20 kW between 40 K and 80 K. The first unit is used for refrigeration at 4.5 K and for the cooling of three sets of 20 kA current leads, while the second one provides, in addition to the 20 kW refrigeration of the thermal shields, 60 kW for the cool-down to 100 K of the 660 ton cold mass of the magnets. The tests, carried out with the equipment in the final underground configuration, are extended to the PCS that includes the large liquid helium centrifugal pumps (each providing 1.2 kg/s) for forced-flow cooling of the magnets and the complex distributi...

  15. Digital microwave communication engineering point-to-point microwave systems

    CERN Document Server

    Kizer, George

    2013-01-01

    The first book to cover all engineering aspects of microwave communication path design for the digital age Fixed point-to-point microwave systems provide moderate-capacity digital transmission between well-defined locations. Most popular in situations where fiber optics or satellite communication is impractical, it is commonly used for cellular or PCS site interconnectivity where digital connectivity is needed but not economically available from other sources, and in private networks where reliability is most important. Until now, no book has adequately treated all en

  16. Turbulence Visualization at the Terascale on Desktop PCs

    KAUST Repository

    Treib, M.

    2012-12-01

    Despite the ongoing efforts in turbulence research, the universal properties of the turbulence small-scale structure and the relationships between small-and large-scale turbulent motions are not yet fully understood. The visually guided exploration of turbulence features, including the interactive selection and simultaneous visualization of multiple features, can further progress our understanding of turbulence. Accomplishing this task for flow fields in which the full turbulence spectrum is well resolved is challenging on desktop computers. This is due to the extreme resolution of such fields, requiring memory and bandwidth capacities going beyond what is currently available. To overcome these limitations, we present a GPU system for feature-based turbulence visualization that works on a compressed flow field representation. We use a wavelet-based compression scheme including run-length and entropy encoding, which can be decoded on the GPU and embedded into brick-based volume ray-casting. This enables a drastic reduction of the data to be streamed from disk to GPU memory. Our system derives turbulence properties directly from the velocity gradient tensor, and it either renders these properties in turn or generates and renders scalar feature volumes. The quality and efficiency of the system is demonstrated in the visualization of two unsteady turbulence simulations, each comprising a spatio-temporal resolution of 10244. On a desktop computer, the system can visualize each time step in 5 seconds, and it achieves about three times this rate for the visualization of a scalar feature volume. © 1995-2012 IEEE.

  17. An optimized power conversion system concept of the integral, inherently-safe light water reactor

    International Nuclear Information System (INIS)

    Memmott, Matthew J.; Wilding, Paul R.; Petrovic, Bojan

    2017-01-01

    Highlights: • Three power conversion systems (PCS) for the I"2S-LWR are presented. • An optimization analyses was performed to evaluate these PCS alternatives. • The ideal PCS consists of 5 turbines, and obtains an overall efficiency of 35.7%. - Abstract: The integral, inherently safe light water reactor (I"2S-LWR) has been developed to significantly enhance passive safety capabilities while maintaining cost competitiveness relative to the current light water reactor (LWR) fleet. The compact heat exchangers of the I"2S-LWR preclude boiling of the secondary fluid, which decreases the probability of heat exchanger failure, but this requires the addition of a flash drum, which negatively affects the overall plant thermodynamic efficiency. A state of the art Rankine cycle is proposed for the I"2S-LWR to increase the thermodynamic efficiency by utilizing a flash drum with optimized operational parameters. In presenting this option for power conversion in the I"2S-LWR power plant, the key metric used in rating the performance is the overall net thermodynamic efficiency of the cycle. In evaluating the flash-Rankine cycle, three basic industrial concepts are evaluated, one without an intermediate pressure turbine, one with an intermediate turbine and one reheat stream, and one with an intermediate turbine and two reheat streams. For each configuration, a single-path multi-variable optimization is undertaken to maximize the thermal efficiency. The third configuration with an intermediate turbine and 2 reheat streams is the most effective concept, with an optimized efficiency of 35.7%.

  18. 2-regularity and 2-normality conditions for systems with impulsive controls

    Directory of Open Access Journals (Sweden)

    Pavlova Natal'ya

    2007-01-01

    Full Text Available In this paper a controlled system with impulsive controls in the neighborhood of an abnormal point is investigated. The set of pairs (u,μ is considered as a class of admissible controls, where u is a measurable essentially bounded function and μ is a finite-dimensional Borel measure, such that for any Borel set B, μ(B is a subset of the given convex closed pointed cone. In this article the concepts of 2-regularity and 2-normality for the abstract mapping Ф, operating from the given Banach space into a finite-dimensional space, are introduced. The concepts of 2-regularity and 2-normality play a great role in the course of derivation of the first and the second order necessary conditions for the optimal control problem, consisting of the minimization of a certain functional on the set of the admissible processes. These concepts are also important for obtaining the sufficient conditions for the local controllability of the nonlinear systems. The convenient criterion for 2-regularity along the prescribed direction and necessary conditions for 2-normality of systems, linear in control, are introduced in this article as well.

  19. The microbiological quality of air improves when using air conditioning systems in cars.

    Science.gov (United States)

    Vonberg, Ralf-Peter; Gastmeier, Petra; Kenneweg, Björn; Holdack-Janssen, Hinrich; Sohr, Dorit; Chaberny, Iris F

    2010-06-01

    Because of better comfort, air conditioning systems are a common feature in automobiles these days. However, its impact on the number of particles and microorganisms inside the vehicle--and by this its impact on the risk of an allergic reaction--is yet unknown. Over a time period of 30 months, the quality of air was investigated in three different types of cars (VW Passat, VW Polo FSI, Seat Alhambra) that were all equipped with a automatic air conditioning system. Operation modes using fresh air from outside the car as well as circulating air from inside the car were examined. The total number of microorganisms and the number of mold spores were measured by impaction in a high flow air sampler. Particles of 0.5 to 5.0 microm diameter were counted by a laser particle counter device. Overall 32 occasions of sampling were performed. The concentration of microorganisms outside the cars was always higher than it was inside the cars. Few minutes after starting the air conditioning system the total number of microorganisms was reduced by 81.7%, the number of mold spores was reduced by 83.3%, and the number of particles was reduced by 87.8%. There were no significant differences neither between the types of cars nor between the types of operation mode of the air conditioning system (fresh air vs. circulating air). All parameters that were looked for in this study improved during utilization of the car's air conditioning system. We believe that the risk of an allergic reaction will be reduced during use also. Nevertheless, we recommend regular maintenance of the system and replacement of older filters after defined changing intervals.

  20. Effects of intestinal bacteria-derived p-cresyl sulfate on Th1-type immune response in vivo and in vitro

    International Nuclear Information System (INIS)

    Shiba, Takahiro; Kawakami, Koji; Sasaki, Takashi; Makino, Ikuyo; Kato, Ikuo; Kobayashi, Toshihide; Uchida, Kazumi; Kaneko, Kimiyuki

    2014-01-01

    Protein fermentation by intestinal bacteria generates various compounds that are not synthesized by their hosts. An example is p-cresol, which is produced from tyrosine. Patients with chronic kidney disease (CKD) accumulate high concentrations of intestinal bacteria-derived p-cresyl sulfate (pCS), which is the major metabolite of p-cresol, in their blood, and this accumulation contributes to certain CKD-associated disorders. Immune dysfunction is a CKD-associated disorder that frequently contributes to infectious diseases among CKD patients. Although some studies imply pCS as an etiological factor, the relation between pCS and immune systems is poorly understood. In the present study, we investigated the immunological effects of pCS derived from intestinal bacteria in mice. For this purpose, we fed mice a tyrosine-rich diet that causes the accumulation of pCS in their blood. The mice were shown to exhibit decreased Th1-driven 2, 4-dinitrofluorobenzene-induced contact hypersensitivity response. The concentration of pCS in blood was negatively correlated with the degree of the contact hypersensitivity response. In contrast, the T cell-dependent antibody response was not influenced by the accumulated pCS. We also examined the in vitro cytokine responses by T cells in the presence of pCS. The production of IFN-γ was suppressed by pCS. Further, pCS decreased the percentage of IFN-γ-producing Th1 cells. Our results suggest that intestinal bacteria-derived pCS suppressesTh1-type cellular immune responses. - Highlights: • Mice fed a tyrosine-rich diet accumulated p-cresyl sulfate in their blood. • p-Cresyl sulfate negatively correlated with contact hypersensitivity response. • The in vitro production of IFN-γ was suppressed by p-cresyl sulfate. • p-Cresyl sulfate decreased the percentage of IFN-γ-producing Th1 cells in vitro