WorldWideScience

Sample records for conditioning facility electrorefiner

  1. Fuel Conditioning Facility Electrorefiner Model Predictions versus Measurements

    Energy Technology Data Exchange (ETDEWEB)

    D Vaden

    2007-10-01

    Electrometallurgical treatment of spent nuclear fuel is performed in the Fuel Conditioning Facility (FCF) at the Idaho National Laboratory (INL) by electrochemically separating uranium from the fission products and structural materials in a vessel called an electrorefiner (ER). To continue processing without waiting for sample analyses to assess process conditions, an ER process model predicts the composition of the ER inventory and effluent streams via multicomponent, multi-phase chemical equilibrium for chemical reactions and a numerical solution to differential equations for electro-chemical transport. The results of the process model were compared to the electrorefiner measured data.

  2. Developing a Signature Based Safeguards Approach for the Electrorefiner and Salt Cleanup Unit Operations in Pyroprocessing Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Chantell Lynne-Marie [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-01-27

    Traditional nuclear materials accounting does not work well for safeguards when applied to pyroprocessing. Alternate methods such as Signature Based Safeguards (SBS) are being investigated. The goal of SBS is real-time/near-real-time detection of anomalous events in the pyroprocessing facility as they could indicate loss of special nuclear material. In high-throughput reprocessing facilities, metric tons of separated material are processed that must be accounted for. Even with very low uncertainties of accountancy measurements (<0.1%) the uncertainty of the material balances is still greater than the desired level. Novel contributions of this work are as follows: (1) significant enhancement of SBS development for the salt cleanup process by creating a new gas sparging process model, selecting sensors to monitor normal operation, identifying safeguards-significant off-normal scenarios, and simulating those off-normal events and generating sensor output; (2) further enhancement of SBS development for the electrorefiner by simulating off-normal events caused by changes in salt concentration and identifying which conditions lead to Pu and Cm not tracking throughout the rest of the system; and (3) new contribution in applying statistical techniques to analyze the signatures gained from these two models to help draw real-time conclusions on anomalous events.

  3. Electrorefining cell evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bronson, M.C.; Thomas, R.L. (ed.)

    1989-04-14

    Operational characteristics of the LANL electrorefining cell, a modified LANL electrorefining cell, and an advanced electrorefining cell (known as the CRAC cell) were determined. Average process yields achieved were: 75% for the LANL cell, 82% for the modified LANL cell, and 86% for the CRAC cell. All product metal from the LANL and modified LANL cells was within foundry specifications. Metal from one run in the CRAC cell exceeded foundry specifications for tantalum. The LANL and modified LANL cells were simple in design and operation, but product separation was more labor intensive than with the CRAC cell. The CRAC cell was more complicated in design but remained relatively simple in operation. A decision analysis concluded that the modified LANL cell was the preferred cell. It was recommended that the modified LANL cell be implemented by the Plutonium Recovery Project at Rocky Flats and that development of the CRAC cell continue. 8 refs., 22 figs., 12 tabs.

  4. Energetics Conditioning Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Energetics Conditioning Facility is used for long term and short term aging studies of energetic materials. The facility has 10 conditioning chambers of which 2...

  5. Retrieving Historical Electrorefining Data

    Energy Technology Data Exchange (ETDEWEB)

    Wheeler, Meagan Daniella [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-18

    Pyrochemical Operations began at Los Alamos National Laboratory (LANL) during 1962 (1). Electrorefining (ER) has been implemented as a routine process since the 1980’s. The process data that went through the ER operation was recorded but had never been logged in an online database. Without a database new staff members are hindered in their work by the lack of information. To combat the issue a database in Access was created to collect the historical data. The years from 2000 onward were entered and queries were created to analyze trends. These trends will aid engineering and operations staff to reach optimal performance for the startup of the new lines.

  6. Inpatient Rehabilitation Facility - Conditions

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of inpatient rehabilitation facilities with data on the number of times people with Medicare who had certain medical conditions were treated in the last year.

  7. Bus bar electrical feedthrough for electrorefiner system

    Science.gov (United States)

    Williamson, Mark; Wiedmeyer, Stanley G; Willit, James L; Barnes, Laurel A; Blaskovitz, Robert J

    2013-12-03

    A bus bar electrical feedthrough for an electrorefiner system may include a retaining plate, electrical isolator, and/or contact block. The retaining plate may include a central opening. The electrical isolator may include a top portion, a base portion, and a slot extending through the top and base portions. The top portion of the electrical isolator may be configured to extend through the central opening of the retaining plate. The contact block may include an upper section, a lower section, and a ridge separating the upper and lower sections. The upper section of the contact block may be configured to extend through the slot of the electrical isolator and the central opening of the retaining plate. Accordingly, relatively high electrical currents may be transferred into a glovebox or hot-cell facility at a relatively low cost and higher amperage capacity without sacrificing atmosphere integrity.

  8. Continuous recovery system for electrorefiner system

    Science.gov (United States)

    Williamson, Mark A.; Wiedmeyer, Stanley G.; Willit, James L.; Barnes, Laurel A.; Blaskovitz, Robert J.

    2014-06-10

    A continuous recovery system for an electrorefiner system may include a trough having a ridge portion and a furrow portion. The furrow portion may include a first section and a second section. An inlet and exit pipe may be connected to the trough. The inlet pipe may include an outlet opening that opens up to the first section of the furrow portion of the trough. The exit pipe may include an entrance opening that opens up to the second section of the furrow portion of the trough. A chain may extend through the inlet and exit pipes and along the furrow portion of the trough. The chain may be in a continuous loop form. A plurality of flights may be secured to the chain. Accordingly, the desired product may be continuously harvested from the electrorefiner system without having to halt the electrical power and/or remove the cathode and anode assemblies.

  9. FY-16 Technology Gap Study Technical Report: Analysis of Undissolved Anode Materials of Mark-IV Electrorefiner

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Tae-Sic [Idaho National Lab. (INL), Idaho Falls, ID (United States); Vaden, DeeEarl [Idaho National Lab. (INL), Idaho Falls, ID (United States); Westphal, Brian Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-01-01

    The Experimental Breeder Reactor II (EBR-II) is a sodium cooled fast reactor developed at Argonne National Laboratory (ANL). The used fuels from the EBR-II are currently being treated in the Fuel Conditioning Facility (FCF) at the Idaho National Laboratory (INL). The Mark IV (Mk-IV) electrorefiner (ER) is a unit process in the FCF, which is primarily assigned to treating the used driver fuels. The stainless steel anode baskets hold the chopped spent driver fuel segments. During electrorefining, the anode baskets are immersed into the electrolyte and the used fuel is dissolved electrochemically. Perforated sides and bottoms allow the flow of the electrolyte into and out of the anode baskets. The steel cathode is also immersed into the electrolyte and collects the reduced products. The active metal contents in the used fuel (e.g., Cs, Sr, lanthanides, Pu, etc.) reacts with uranium cations in the electrolyte and progressively reports to the electrolyte. Noble metals are mostly retained in the cladding hulls. Varying quantities of zirconium are retained in the cladding hulls depending on the operational conditions of the Mk-IV ER. The undissolved anode materials are removed from the anode baskets and stored for subsequent metal waste form processing. These undissolved materials typically include undissolved fuels, stainless steel cladding, and adhering electrolyte. A couple of hulls are retrieved for chemical analysis and used for estimating the composition of the entire undissolved anode materials. The mass balance attempt based on this practice of estimating the undissolved anode materials has been a challenge due to inherently high sampling errors associated with heterogeneous undissolved material compositions. Responding to the prescribed challenge, this report investigates chemical analysis data as a whole and finds noticeable trends in the compositions of undissolved anode material samples with respect to the mass of the whole undissolved anode materials. Based

  10. School Facility Conditions and Student Academic Achievement

    OpenAIRE

    Earthman, Glen I.

    2002-01-01

    This paper shows that the condition of school facilities has an important impact on student performance and teacher effectiveness. In particular, research demonstrates that comfortable classroom temperature and noise level are very important to efficient student performance. The age of school buildings is a useful proxy in this regard, since older facilities often have problems with thermal environment and noise level. A number of studies have measured overall building condition and its conne...

  11. Electrorefining of uranium and plutonium from liquid cadmium

    Energy Technology Data Exchange (ETDEWEB)

    Tomczuk, Z.; Poa, D.S.; Miller, W.E.; Steunenberg, R.K.

    1985-01-01

    Feasibility of electrorefining of U, Pu, and mixtures thereof using a liquid Cd anode and a molten-salt electrolyte was investigated for the proposed pyrometallurgical process for the Integral Fast Reactor fuel. (DLC)

  12. 42 CFR 493.1100 - Condition: Facility administration.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Facility administration. 493.1100 Section 493.1100 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Facility Administration for Nonwaived Testing § 493.1100 Condition: Facility...

  13. Characterization of a ceramic waste form encapsulating radioactive electrorefiner salt

    Energy Technology Data Exchange (ETDEWEB)

    Moschetti, T. L.; Sinkler, W.; DiSanto, T.; Noy, M.; Warren, A. R.; Cummings, D. G.; Johnson, S. G.; Goff, K. M.; Bateman, K. J.; Frank, S. M.

    1999-11-11

    Argonne National Laboratory has developed a ceramic waste form to immobilize radioactive waste salt produced during the electrometallurgical treatment of spent fuel. This study presents the first results from electron microscopy and durability testing of a ceramic waste form produced from that radioactive electrorefiner salt. The waste form consists of two primary phases: sodalite and glass. The sodalite phase appears to incorporate most of the alkali and alkaline earth fission products. Other fission products (rare earths and yttrium) tend to form a separate phase and are frequently associated with the actinides, which form mixed oxides. Seven-day leach test results are also presented.

  14. Electrochemical concentration measurements for multianalyte mixtures in simulated electrorefiner salt

    Science.gov (United States)

    Rappleye, Devin Spencer

    The development of electroanalytical techniques in multianalyte molten salt mixtures, such as those found in used nuclear fuel electrorefiners, would enable in situ, real-time concentration measurements. Such measurements are beneficial for process monitoring, optimization and control, as well as for international safeguards and nuclear material accountancy. Electroanalytical work in molten salts has been limited to single-analyte mixtures with a few exceptions. This work builds upon the knowledge of molten salt electrochemistry by performing electrochemical measurements on molten eutectic LiCl-KCl salt mixture containing two analytes, developing techniques for quantitatively analyzing the measured signals even with an additional signal from another analyte, correlating signals to concentration and identifying improvements in experimental and analytical methodologies. (Abstract shortened by ProQuest.).

  15. I-NERI ANNUAL TECHNICAL PROGRESS REPORT: 2006-002-K, Separation of Fission Products from Molten LiCl-KCl Salt Used for Electrorefining of Metal Fuels

    Energy Technology Data Exchange (ETDEWEB)

    S. Frank

    2009-09-01

    An attractive alternative to the once-through disposal of electrorefiner salt is to selectively remove the active fission products from the salt and recycle the salt back to the electrorefiner (ER). This would allow salt reuse for some number of cycles before ultimate disposal of the salt in a ceramic waste form. Reuse of ER salt would, thus, greatly reduce the volume of ceramic waste produced during the pyroprocessing of spent nuclear fuel. This final portion of the joint I-NERI research project is to demonstrate the separation of fission products from molten ER salt by two methods previously selected during phase two (FY-08) of this project. The two methods selected were salt/zeolite contacting and rare-earth fission product precipitation by oxygen bubbling. The ER salt used in these tests came from the Mark-IV electrorefiner used to anodically dissolved driver fuel from the EBR-II reactor on the INL site. The tests were performed using the Hot Fuel Dissolution Apparatus (HFDA) located in the main cell of the Hot Fuels Examination Facility (HFEF) at the Materials and Fuels complex on the INL site. Results from these tests were evaluated during a joint meeting of KAERI and INL investigators to provide recommendations as to the future direction of fission product removal from electrorefiner salt that accumulate during spent fuel treatment. Additionally, work continued on kinetic measurements of surrogate quaternary salt systems to provide fundamental kinetics on the ion exchange system and to expand the equilibrium model system developed during the first two phases of this project. The specific objectives of the FY09 I-NERI research activities at the INL include the following: • Perform demonstration tests of the selected KAERI precipitation and INL salt/zeolite contacting processes for fission product removal using radioactive, fission product loaded ER salt • Continue kinetic studies of the quaternary Cs/Sr-LiCl-KCl system to determine the rate of ion

  16. Sufficient conditions for optimal facility locations to coincide

    DEFF Research Database (Denmark)

    Juel, Henrik; Love, Robert F.

    1980-01-01

    In some cases multifacility location problems may be solved by verifying a few simple inequalities involving the interfacility weights. The authors develop certain inequalities which are sufficient conditions for optimality in some multifacility problems. In the problems considered, distances are...... are represented by a symmetric metric and there are no constraints on the location of the new facilities......In some cases multifacility location problems may be solved by verifying a few simple inequalities involving the interfacility weights. The authors develop certain inequalities which are sufficient conditions for optimality in some multifacility problems. In the problems considered, distances...

  17. Roadmap for disposal of Electrorefiner Salt as Transuranic Waste.

    Energy Technology Data Exchange (ETDEWEB)

    Rechard, Robert P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Trone, Janis R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kalinina, Elena Arkadievna [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wang, Yifeng [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hadgu, Teklu [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sanchez, Lawrence C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-12-01

    The experimental breeder reactor (EBR-II) used fuel with a layer of sodium surrounding the uranium-zirconium fuel to improve heat transfer. Disposing of EBR-II fuel in a geologic repository without treatment is not prudent because of the potentially energetic reaction of the sodium with water. In 2000, the US Department of Energy (DOE) decided to treat the sodium-bonded fuel with an electrorefiner (ER), which produces metallic uranium product, a metallic waste, mostly from the cladding, and the salt waste in the ER, which contains most of the actinides and fission products. Two waste forms were proposed for disposal in a mined repository; the metallic waste, which was to be cast into ingots, and the ER salt waste, which was to be further treated to produce a ceramic waste form. However, alternative disposal pathways for metallic and salt waste streams may reduce the complexity. For example, performance assessments show that geologic repositories can easily accommodate the ER salt waste without treating it to form a ceramic waste form. Because EBR-II was used for atomic energy defense activities, the treated waste likely meets the definition of transuranic waste. Hence, disposal at the Waste Isolation Pilot Plant (WIPP) in southern New Mexico, may be feasible. This report reviews the direct disposal pathway for ER salt waste and describes eleven tasks necessary for implementing disposal at WIPP, provided space is available, DOE decides to use this alternative disposal pathway in an updated environmental impact statement, and the State of New Mexico grants permission.

  18. Understanding Functional Adequacy and Facility Condition for Strategic Decision Making

    Science.gov (United States)

    Dufresne, Ray

    2012-01-01

    At colleges and universities today, the increasing number of students is putting new pressure on facilities--and on facility staff. Student needs are also increasingly different, and most campus facilities have not kept up with the changing times. Facilities are expensive to build, maintain, and renovate, and costs are on the rise. Funds for…

  19. Thermal Analysis of Surrogate Simulated Molten Salts with Metal Chloride Impurities for Electrorefining Used Nuclear Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Toni Y. Gutknecht; Guy L. Fredrickson; Vivek Utgikar

    2012-04-01

    This project is a fundamental study to measure thermal properties (liquidus, solidus, phase transformation, and enthalpy) of molten salt systems of interest to electrorefining operations, which are used in both the fuel cycle research & development mission and the spent fuel treatment mission of the Department of Energy. During electrorefining operations the electrolyte accumulates elements more active than uranium (transuranics, fission products and bond sodium). The accumulation needs to be closely monitored because the thermal properties of the electrolyte will change as the concentration of the impurities increases. During electrorefining (processing techniques used at the Idaho National Laboratory to separate uranium from spent nuclear fuel) it is important for the electrolyte to remain in a homogeneous liquid phase for operational safeguard and criticality reasons. The phase stability of molten salts in an electrorefiner may be adversely affected by the buildup of fission products in the electrolyte. Potential situations that need to be avoided are: (i) build up of fissile elements in the salt approaching the criticality limits specified for the vessel (ii) freezing of the salts due to change in the liquidus temperature and (iii) phase separation (non-homogenous solution) of elements. The stability (and homogeneity) of the phases can potentially be monitored through the thermal characterization of the salts, which can be a function of impurity concentration. This work describes the experimental results of typical salts compositions, consisting of chlorides of strontium, samarium, praseodymium, lanthanum, barium, cerium, cesium, neodymium, sodium and gadolinium (as a surrogate for both uranium and plutonium), used in the processing of used nuclear fuels. Differential scanning calorimetry was used to analyze numerous salt samples providing results on the thermal properties. The property of most interest to pyroprocessing is the liquidus temperature. It was

  20. Arc Jet Facility Test Condition Predictions Using the ADSI Code

    Science.gov (United States)

    Palmer, Grant; Prabhu, Dinesh; Terrazas-Salinas, Imelda

    2015-01-01

    The Aerothermal Design Space Interpolation (ADSI) tool is used to interpolate databases of previously computed computational fluid dynamic solutions for test articles in a NASA Ames arc jet facility. The arc jet databases are generated using an Navier-Stokes flow solver using previously determined best practices. The arc jet mass flow rates and arc currents used to discretize the database are chosen to span the operating conditions possible in the arc jet, and are based on previous arc jet experimental conditions where possible. The ADSI code is a database interpolation, manipulation, and examination tool that can be used to estimate the stagnation point pressure and heating rate for user-specified values of arc jet mass flow rate and arc current. The interpolation is performed in the other direction (predicting mass flow and current to achieve a desired stagnation point pressure and heating rate). ADSI is also used to generate 2-D response surfaces of stagnation point pressure and heating rate as a function of mass flow rate and arc current (or vice versa). Arc jet test data is used to assess the predictive capability of the ADSI code.

  1. Analysis of Cadmium in Undissolved Anode Materials of Mark-IV Electrorefiner

    Energy Technology Data Exchange (ETDEWEB)

    Tae-Sic Yoo; Guy L. Fredrickson; DeeEarl Vaden; Brian R. Westphal

    2013-10-01

    The Mark-IV electrorefiner (Mk-IV ER) contains an electrolyte/molten cadmium system for refining uranium electrochemically. Typically, the anode of the Mk-IV ER consists of the chopped sodium-bonded metallic driver fuels, which have been primarily U-10Zr binary fuels. Chemical analysis of the residual anode materials after electrorefining indicates that a small amount of cadmium is removed from the Mk-IV ER along with the undissolved anode materials. Investigation of chemical analysis data indicates that the amount of cadmium in the undissolved anode materials is strongly correlated with the anode rotation speeds and the residence time of the anode in the Mk-IV ER. Discussions are given to explain the prescribed correlation.

  2. 42 CFR 483.450 - Condition of participation: Client behavior and facility practices.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition of participation: Client behavior and... Retarded § 483.450 Condition of participation: Client behavior and facility practices. (a) Standard: Facility practices—Conduct toward clients. (1) The facility must develop and implement written policies and...

  3. 42 CFR 494.120 - Condition: Special purpose renal dialysis facilities.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Special purpose renal dialysis... RENAL DISEASE FACILITIES Patient Care § 494.120 Condition: Special purpose renal dialysis facilities. A special purpose renal dialysis facility is approved to furnish dialysis on a short-term basis at special...

  4. RELAP5 Simulation of PKL Facility Experiments under Midloop Conditions

    Directory of Open Access Journals (Sweden)

    J. F. Villanueva

    2017-01-01

    Full Text Available Nuclear power plant risk has to be quantified in full power and in other modes of operation. This latter situation corresponds to low power and shutdown modes of operation in which the residual heat removal (RHR system is required to extract the heat generated in the core. These accidental sequences are great contributors to the total plant risk. Thus, it is important to analyze the plant behavior to establish the accident mitigation measures required. In this way, PKL facility experimental series were undertaken to analyze the plant behavior in other modes of operation when the RHR is lost. In these experiments, the plant configurations were changed to analyze the influence of steam generators secondary side configurations, the temperature inside the pressurizer, and the inventory level on the plant behavior. Moreover, different accident management measures were proposed in each experiment to reach the conditions to restart the RHR. To understand the physical phenomena that takes place inside the reactor, the experiments are simulated with thermal-hydraulic codes, and this makes it possible to analyze the code capabilities to predict the plant behavior. This work presents the simulation results of four experiments included in PKL experimental series obtained using RELAP5/Mod3.3.

  5. The application of electrorefining for recovery and purification of fuel discharged from the Integral Fast Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Burris, L.; Steunenberg, R.K.; Miller, W.E.

    1986-01-01

    An electrorefining process employing a molten salt electrolyte and a molten cadmium anode is proposed for the separation of uranium and plutonium from fission products and cladding material in discharged IFR driver fuel. The use of a liquid cadmium anode, which is the unique feature of the process, permits selective dissolution of the fuel from the cladding and prevents electrolytic corrosion of the steel container and contamination of the product by noble metal fission products.

  6. Transient modeling of spent nuclear fuel electrorefining with liquid metal electrode

    Science.gov (United States)

    Seo, Seungjin; Choi, Sungyeol; Park, Byung Gi

    2017-08-01

    During the molten salt electrorefining of spent nuclear fuel, multiple phases such as oxide, solid metal, liquid metal, and molten salt often co-exist. Computational modeling can be a useful tool for understanding the reaction mechanism across the multiple phases. The new model has been developed and applied to a lab-scale electrorefining with liquid metal anode and solid cathode LiCl-KCl molten salt. The benchmark study predicts anodic dissolution and cathodic deposition of U and Pu with minor disagreements. In particular, the on-set of Pu deposition on the surface of the solid cathode is well estimated, which is important for the quality of U ingot and the safeguards of process. The underestimation of U deposition (∼6%) and the overestimation of Pu dissolution (∼7%) at the end of simulation are explained by unconsidered reaction species such as Np and Am from the liquid Cd anode, which overestimates the dissolution of Pu from the anode compared to the measured data. The sensitivity study also reveals the transition behaviors of electrochemical reactions for U and Pu on the solid cathode are changed by diffusion boundary layer thickness, transfer coefficients, and the difference of electrochemical potentials more sensitively than those of the liquid metal anode. For this specific experiment case, the thinner diffusion boundary layer improves the prediction of cathodic reactions particularly at the end of electrorefining.

  7. 40 CFR 86.161-00 - Air conditioning environmental test facility ambient requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Air conditioning environmental test... conditioning environmental test facility ambient requirements. The goal of an air conditioning test facility is... elements that are discussed are ambient air temperature and humidity, minimum test cell size, solar heating...

  8. Facilities Condition and Hazards Assessment for Materials and Fuel Complex Facilities MFC-799, 799A, and 770C

    Energy Technology Data Exchange (ETDEWEB)

    Gary Mecham; Don Konoyer

    2009-11-01

    The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these facilities. This information will document conditions at time of transfer of the facilities from Nuclear Energy to Environmental Management and serve as the basis for disposition planning. The process used in obtaining this information included document searches, interviews and facility walk-downs. A copy of the facility walk-down checklist is included in this report as Appendix A. MFC-799/799A/770C are all structurally sound and associated hazardous or potentially hazardous conditions are well defined and well understood. All installed equipment items (tanks, filters, etc.) used to process hazardous materials remain in place and appear to have maintained their integrity. There is no evidence of leakage and all openings are properly sealed or closed off and connections are sound. The pits appear clean with no evidence of cracking or deterioration that could lead to migration of contamination. Based upon the available information/documentation reviewed and the overall conditions observed during the facilities walk-down, it is concluded that these facilities may be disposed of

  9. Evaluation of the electrorefining technique for the processing of radioactive scrap metals

    Energy Technology Data Exchange (ETDEWEB)

    Kessinger, G.F.

    1993-10-01

    This report presents the results of a literature study performed to identify applications of the electrorefining technique to the decontamination of radioactively-contaminated scrap metal (RSM). Upon the completion of the literature search and the review of numerous references, it was concluded that there were applications of this technique that were appropriate for the decontamination of some types of RSM, especially when the desired product is a pure elemental metal of high purity. It was also concluded that this technique was not well-suited for the decontamination of RSM stainless steels and other alloys, when it was desired that the metallurgical characteristics of the alloy be present in the decontaminated product.

  10. Conceptual design study of an integrated pyro-process facility at KAERI

    Energy Technology Data Exchange (ETDEWEB)

    You, Gil-Sung; Choung, Won-Myung; Lee, Eun-Pyo; Cho, Il-Je; Kwon, Kie-Chan; Hong, Dong-Hee; Lee, Won-Kyung; Ku, Jeong-Hoe [Korea Atomic Energy Research Institute, 1045 Daedeok-daero, Yuseong-gu, Daejeon, 305-353 (Korea, Republic of)

    2009-06-15

    KAERI has been developing pyro-process facilities for a dry processing research of spent fuel about ten years since 1997. A hot cell facility, named the ACPF-Advanced spent fuel Conditioning Process Facility, for the demonstration of a head-end part of pyro-process was developed at November 2005. An inactive demonstration facility for the integrated pyro-process, named PRIDE-pyro-process Integrated inactive Demonstration, has been developing since 2007. The PRIDE facility consists of two cells: one is an air environment cell and another one is an argon environment cell. This facility includes several pyro-process equipment, such as a decladding/voloxidation device, a powder mixing device, an electro-reduction equipment, an electro-refining equipment, an electro-winning equipment, a Cd distillation equipment, a waste salt regeneration and solidification equipment, a salt distillation equipment, etc. In the cell and on the wall, some cell equipment, such as one cell crane, one BTDSM (Bridge Transported Dual arm Servo Manipulator), two HMSM (Horizontally Moving dual arm Servo Manipulator) will be also installed. This facility will be utilized to obtain the basic requirements for an engineering scale pyro-process facility in which the spent fuels from power reactors can be treated. (authors)

  11. Electrorefining of High Carbon Ferromanganese in Molten Salts to Produce Pure Ferromanganese

    Directory of Open Access Journals (Sweden)

    Xiao S. J.

    2017-09-01

    Full Text Available High carbon ferromanganese is used as a starting material to prepare pure ferromanganese by electrorefining in molten salts. High carbon ferromanganese was applied as the anode, molybdenum was the cathode and Ag/AgCl was the reference electrode. The anodic dissolution was investigated by linear polarization in molten NaCl-KCl system. Then potentiostatic electrolysis was carried out to produce pure ferromanganese from high carbon ferromanganese. The cathodic product was determined to be a mixture of manganese and iron by x-ray diffraction (XRD. The content of carbon in the product was analyzed by carbon and sulfur analyzer. The post-electrolysis anode was characterized by scanning electron microscope (SEM. The mechanism of the anode dissolution and the distribution of the main impurity of carbon and silicon after electrolysis were discussed.

  12. Adverse Condition and Critical Event Prediction in Cranfield Multiphase Flow Facility

    DEFF Research Database (Denmark)

    Egedorf, Søren; Shaker, Hamid Reza

    2017-01-01

    alarm and missed detection rates. While ACCEPT has shown to be an effective tool in some applications, its performance has not yet been evaluated on practical well-known benchmark examples. In this paper, ACCEPT is used for adverse condition and critical event prediction in a multiphase flow facility....... Cranfield multiphase flow facility is known to be an interesting benchmark which has been used to evaluate different methods from statistical process monitoring. In order to allow for the data from the flow facility to be used in ACCEPT, methods such as Kernel Density Estimation (KDE), PCA-and CVA...

  13. A PROBABILISTIC INVENTORY MODEL FOR CONDITIONAL CREDIT PERIOD AND LEAD TIME WITH MULTIPLE STORAGE FACILITIES

    OpenAIRE

    Mishra, S.S.; Himanshu Pandey; Singh, R.S.

    2008-01-01

    A probabilistic inventory model for conditional credit period with exponential demand, non-zero lead time and multiple storage facility has been developed. The behaviour of total expected cost (TEC) has been examined and the use and application of the model is demonstrated with the help of a numerical example.

  14. 48 CFR 970.5215-3 - Conditional payment of fee, profit, and other incentives-facility management contracts

    Science.gov (United States)

    2010-10-01

    ..., profit, and other incentives-facility management contracts 970.5215-3 Section 970.5215-3 Federal....5215-3 Conditional payment of fee, profit, and other incentives—facility management contracts As... Incentives—Facility Management Contracts (AUG 2009) (a) General. (1) The payment of earned fee, fixed fee...

  15. Synthesis and casting of a lithium-bismuth compound for an ion-replacement electrorefiner.

    Energy Technology Data Exchange (ETDEWEB)

    McDeavitt, S. M.

    1998-11-23

    The intermetallic compound Li{sub 3}Bi played an integral part in the demonstration of an ion replacement electrorefining method developed at Argonne National Laboratory. The Li{sub 3}Bi compound was generated in a tilt-pour casting furnace using high-purity lithium and bismuth metals as the initial charge. At first, small-scale ({approximately}20 g) experiments were conducted to determine the materials synthesis parameters. In the end, four larger-scale castings (500 g to 1250 g) were completed in a tantalum crucible. The metals were heated slowly to melt the charge, and the formation reaction proceeded vigorously above the melting point of bismuth ({approximately}270 C). For the large-scale melts, the furnace power was temporarily turned off at this point. After several minutes, the tantalum crucible stopped glowing, and the furnace power was turned on. The temperature was then increased to {approximately}1200 C to melt and homogenize the compound, and liquid Li{sub 3}Bi was cast into cold stainless steel molds. Approximately 3.7 kg of Li{sub 3}Bi was generated by this method.

  16. [Technical and sanitary conditions of food service facilities in nurseries in Poland 1975-1985].

    Science.gov (United States)

    Wojdon-Machała, H

    1990-01-01

    In the years 1975-1985 three times at intervals of 5 years the technical and hygienic condition was checked of the catering facilities of nurseries+ in a 40% randomly selected sample. The aim of the study was establishing whether in the years of increasing economic crisis, despite protective measures introduced by the authorities, detectable changes have taken place ot the advantage or disadvantage in the catering facilities, since a proper standard of this part of the nurseries is indispensable for a normal growth and health of children raised in institutions. In the first analysed 5-year period (1975-1980) some improvement was noted, especially in the technical equipment of these facilities. This was connected with greater investments provided for building of nurseries , resulting in a rise in the proportion of nurseries built according to the accepted building standard to 56%. In this way the number of nurseries with normal functional parameters increased. In the following 5-year period this condition was maintained owing to building of new nurseries although in lower number, while at the same time the worst crêches were liquidated in areas where the requirements for places in crêches have dropped. It was noted that in every third crêche the catering facilities were below the accepted hygienic standard for such institutions, and this situation continued since several years. The quality and timing of meals were incompatible with the principles of rational nutrition already at the stage of menu planning. Activities should be taken for ensuring proper hygienic conditions in the catering facilities in crêches and for improving the nutrition by correct composition of menu.

  17. The relationship between science classroom facility conditions and ninth grade students' attitudes toward science

    Science.gov (United States)

    Ford, Angela Y.

    Over half of the school facilities in America are in poor condition. Unsatisfactory school facilities have a negative impact on teaching and learning. The purpose of this correlational study was to identify the relationship between high school science teachers' perceptions of the school science environment (instructional equipment, demonstration equipment, and physical facilities) and ninth grade students' attitudes about science through their expressed enjoyment of science, importance of time spent on science, and boredom with science. A sample of 11,523 cases was extracted, after a process of data mining, from a databank of over 24,000 nationally representative ninth graders located throughout the United States. The instrument used to survey these students was part of the High School Longitudinal Study of 2009 (HSLS:2009). The research design was multiple linear regression. The results showed a significant relationship between the science classroom conditions and students' attitudes. Demonstration equipment and physical facilities were the best predictors of effects on students' attitudes. Conclusions based on this study and recommendations for future research are made.

  18. Projected Salt Waste Production from a Commercial Pyroprocessing Facility

    OpenAIRE

    Simpson, Michael F.

    2013-01-01

    Pyroprocessing of used nuclear fuel inevitably produces salt waste from electrorefining and/or oxide reduction unit operations. Various process design characteristics can affect the actual mass of such waste produced. This paper examines both oxide and metal fuel treatment, estimates the amount of salt waste generated, and assesses potential benefit of process options to mitigate the generation of salt waste. For reference purposes, a facility is considered in which 100 MT/year of fuel is pro...

  19. Prediction of the radiation situation during conditioned radioactive waste storage in hangar-type storage facilities

    Science.gov (United States)

    Rosnovskii, S. V.; Bulka, S. K.

    2014-02-01

    An original technology for the conditioning of solidified radioactive waste was developed by the Novovoronezh nuclear power plant (NPP) staff. The technology provides for waste placement inside NZK-150-1.5P containers with their further storage at light hangar-type storage facilities. A number of technical solutions were developed that allow for reducing the gamma-radiation dose rate from the package formed. A methodology for prediction of the radiation situation around hangars, depending on the radiation characteristics of irrecoverable shielding containers (ISCs) located in the peripheral row of a storage facility, was developed with the purpose of assuring safe storage. Based on empirical data, the field background gamma-radiation dose rate at an area as a function of the average dose rate at the hangar surface and the average dose rate close packages, placed in the peripheral row of the storage facility, was calculated. The application of the developed methodology made it possible to reduce by ten times the expenditures for the conditioning and holding of solidified radioactive waste (SRW) while unconditionally providing storage safety.

  20. Facile route to multi-walled carbon nanotubes under ambient conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Hyunchul; Jeong, Soo-Hwan [Kyungpook National University, Daegu (Korea, Republic of)

    2016-02-15

    A facile and practical route is demonstrated to prepare multi-walled carbon nanotubes (MWCNTs) by a sonochemical method. By applying ultrasonic irradiation to the mixture of ferrocene and xylene with small amount of water, crystalline MWCNTs were selectively synthesized under ambient conditions, allowing MWCNTs with diameter of 25-40 nm to be obtained. A control experiment revealed that a small amount of water was essential for producing MWCNTs. The analysis of Raman spectra of MWCNTs showed that the intensity of the D-band relative to the G-band was 0.98, indicating relatively good crystallinity of these MWCNTs. This result was consistent with that of TEM observation.

  1. Electrorefining of U-Pu-Zr-alloy fuel onto solid aluminium cathodes in molten LiCl-KCl

    Energy Technology Data Exchange (ETDEWEB)

    Soucek, P.; Malmbeck, R.; Mendes, E.; Jardin, R.; Glatz, J.P. [European Commission, JRC, Karlsruhe (Germany). Inst. for Transuranium Elements; Cassayre, L. [Lab. de Genie Chimique (LGC), Univ. Paul Sabatier, UMR CNRS 5503, Toulouse (France)

    2008-07-01

    An electrorefining process in molten chloride salts using solid aluminium cathodes is being developed at ITU to recover actinides (An) from the spent nuclear fuel. The maximum possible loading of aluminium electrodes with actinides was investigated during the electrorefining of U-Pu-Zr alloy in a LiCl-KCl eutectic at 450 C. Two different electrolytic techniques were applied during the experiment and almost 6000 C has been passed, corresponding to 3.7 g of deposited actinides. A very high capacity of aluminium to retain actinides has been proven as the average Al: An mass ratio was 1: 1.58 for galvanostatic and 1: 2.25 for potentiostatic mode. The obtained deposits were characterized by XRD and SEM-EDX analysis and alloys composed of (U,Pu)Al{sub 3} were detected. The influence of zirconium co-oxidation during the process was also investigated and the presence of dissolved Zr ions in the melt yielded a significant deterioration of the quality of the deposit. (orig.)

  2. Preoperational Subsurface Conditions at the Idaho Nuclear Technology and Engineering Center Service Waste Disposal Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ansley, Shannon Leigh

    2002-02-01

    The Idaho Nuclear Technology and Engineering Center (INTEC) Service Wastewater Discharge Facility replaces the existing percolation ponds as a disposal facility for the INTEC Service Waste Stream. A preferred alternative for helping decrease water content in the subsurface near INTEC, closure of the existing ponds is required by the INTEC Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Record of Decision (ROD) for Waste Area Group 3 Operable Unit 3-13 (DOE-ID 1999a). By August 2002, the replacement facility was constructed approximately 2 miles southwest of INTEC, near the Big Lost River channel. Because groundwater beneath the Idaho National Engineering and Environmental Laboratory (INEEL) is protected under Federal and State of Idaho regulations from degradation due to INEEL activities, preoperational data required by U.S. Department of Energy (DOE) Order 5400.1 were collected. These data include preexisting physical, chemical, and biological conditions that could be affected by the discharge; background levels of radioactive and chemical components; pertinent environmental and ecological parameters; and potential pathways for human exposure or environmental impact. This document presents specific data collected in support of DOE Order 5400.1, including: four quarters of groundwater sampling and analysis of chemical and radiological parameters; general facility description; site specific geology, stratigraphy, soils, and hydrology; perched water discussions; and general regulatory requirements. However, in order to avoid duplication of previous information, the reader is directed to other referenced publications for more detailed information. Documents that are not readily available are compiled in this publication as appendices. These documents include well and borehole completion reports, a perched water evaluation letter report, the draft INEEL Wellhead Protection Program Plan, and the Environmental Checklist.

  3. A comparative study on the metering accuracy for given installation conditions of metering facility

    Energy Technology Data Exchange (ETDEWEB)

    Her, Jae Young; Lee, Seung Jun; Ha, Young Cheol; Ahn, Seung Hee; Lee, Cheol Gu [R and D Center, Korea Gas Co., (Korea)

    1999-12-01

    The object of this study is to improve metering facilities of Korea Gas Corporation(KOGAS) metering station which are being operated in unfavorable straight pipe length condition (metropolitan area). For experiment, a test facilities was modeled based on Dogsan metering station (one of KOGAS metering stations) which has the most unfavorable conditions in metropolitan area. The test facilities was set up in Jungdong metering station (one of KOGAS metering stations) supplying natural gas to a power plant and city gas companies. The tests were performed with flowconditioner which was installed in the former straight pipe of a turbine meter and an Orifice meter, and the tests keep going with changing both diameter ratio({beta} = d/D) and flowrate(Q{sub v}). In other words, the tests were performed according to flowrate change for fixed diameter ratio. After the test was completed, the diameter ratio was increased by 0.1 and the same procedures were conducted again. The test was conducted for diameter ratio from 0.3 to 0.7. For Orifice meter, the error showed 0.4 %(Test maximum flowrate=3,030 Nm{sup 3}/h) and 0.8 %(Test maximum flowrate=9,204 Nm{sup 3}/h) for {beta}=0.3 and 0.7, respectively. For Turbine meter, the error showed -0.5 %(Test maximum flowrate=3,030 Nm{sup 3}/h) and -0.1 %(Test maximum flowrate=9,204 Nm{sup 3}/h) for {beta}=0.3 and 0.7, respectively. 44 refs., 32 figs., 27 tabs.

  4. How to improve the irradiation conditions for the International Fusion Materials Irradiation Facility

    CERN Document Server

    Daum, E

    2000-01-01

    The accelerator-based intense D-Li neutron source International Fusion Materials Irradiation Facility (IFMIF) provides very suitable irradiation conditions for fusion materials development with the attractive option of accelerated irradiations. Investigations show that a neutron moderator made of tungsten and placed in the IFMIF test cell can further improve the irradiation conditions. The moderator softens the IFMIF neutron spectrum by enhancing the fraction of low energy neutrons. For displacement damage, the ratio of point defects to cascades is more DEMO relevant and for tritium production in Li-based breeding ceramic materials it leads to a preferred production via the sup 6 Li(n,t) sup 4 He channel as it occurs in a DEMO breeding blanket.

  5. Radio-Ecological Conditions of Groundwater in the Area of Uranium Mining and Milling Facility - 13525

    Energy Technology Data Exchange (ETDEWEB)

    Titov, A.V.; Semenova, M.P.; Seregin, V.A.; Isaev, D.V.; Metlyaev, E.G. [FSBU SRC A.I.Burnasyan Federal Medical Biophysical Center of FMBA of Russia, Zhivopisnaya Street, 46, Moscow (Russian Federation); Glagolev, A.V.; Klimova, T.I.; Sevtinova, E.B. [FSESP ' Hydrospecgeologiya' (Russian Federation); Zolotukhina, S.B.; Zhuravleva, L.A. [FSHE ' Centre of Hygiene and Epidemiology no. 107' under FMBA of Russia (Russian Federation)

    2013-07-01

    Manmade chemical and radioactive contamination of groundwater is one of damaging effects of the uranium mining and milling facilities. Groundwater contamination is of special importance for the area of Priargun Production Mining and Chemical Association, JSC 'PPMCA', because groundwater is the only source of drinking water. The paper describes natural conditions of the site, provides information on changes of near-surface area since the beginning of the company, illustrates the main trends of contaminators migration and assesses manmade impact on the quality and mode of near-surface and ground waters. The paper also provides the results of chemical and radioactive measurements in groundwater at various distances from the sources of manmade contamination to the drinking water supply areas. We show that development of deposits, mine water discharge, leakages from tailing dams and cinder storage facility changed general hydro-chemical balance of the area, contributed to new (overlaid) aureoles and flows of scattering paragenetic uranium elements, which are much smaller in comparison with natural ones. However, increasing flow of groundwater stream at the mouth of Sukhoi Urulyungui due to technological water infiltration, mixing of natural water with filtration streams from industrial reservoirs and sites, containing elevated (relative to natural background) levels of sulfate-, hydro-carbonate and carbonate- ions, led to the development and moving of the uranium contamination aureole from the undeveloped field 'Polevoye' to the water inlet area. The aureole front crossed the southern border of water inlet of drinking purpose. The qualitative composition of groundwater, especially in the southern part of water inlet, steadily changes for the worse. The current Russian intervention levels of gross alpha activity and of some natural radionuclides including {sup 222}Rn are in excess in drinking water; regulations for fluorine and manganese

  6. Fuel Performance Characterisation under Various PWR Conditions: Description of the Annealing Test Facilities available at the LECA-STAR laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Pontillon, Y.; Cornu, B.; Clement, S.; Ferroud-Plattet, M.P.; Malgouyres, P.P. [Commissariat a l' Energie Atomique, CEA/DEN/DEC/SA3C - Centre d' Etudes de Cadarache, BP1, 13108 Saint Paul Lez Durance (France)

    2008-07-01

    The aim to improve LWR fuel behaviour has led Cea to improve its post-irradiation examination capacities in term of test facilities and characterization techniques in the shielded hot cells of the LECA-STAR facility, located in Cadarache Cea center. as far as the annealing test facilities are concerned, fuel qualification and improvement of knowledge require a set of furnaces which are already used or will be used. The main characteristics of these furnaces strongly depend on the experimental objectives. The aim of this paper is to review the main aspects of these specific experiments concerning: (i) fission gas release from high burn up fuel, (ii) global fission product release in severe-accident conditions and (iii) fuel microstructural changes, potential cladding failure, radionuclide source terms... under conditions representative of long term dry storage and geological disposal. (authors)

  7. A Guide for Developing Standard Operating Job Procedures for the Sludge Conditioning & Dewatering Process Wastewater Treatment Facility. SOJP No. 11.

    Science.gov (United States)

    Schwing, Carl M.

    This guide describes standard operating job procedures for the sludge conditioning and dewatering process of wastewater treatment facilities. In this process, sludge is treated with chemicals to make the sludge coagulate and give up its water more easily. The treated sludge is then dewatered using a vacuum filter. The guide gives step-by-step…

  8. [Preoperational study for the improvement of hygiene conditions in long-term care facilities].

    Science.gov (United States)

    Adler, A C; Spegel, H; Kolb, S; Hierl, W; Müller, C; Höller, C; Liebl, B; Rudolph, P; Herr, C

    2014-12-01

    Hygiene is becoming more and more important in long-term care facilities. Long-term care facilities are subject to monitoring by the Public Health Service (PHS) and other authorities. For the PHS in Bavaria the Bavarian Health and Food Safety Authority (Landesamt für Gesundheit und Lebensmittelsicherheit, LGL) published a hygiene monitoring concept and there exists an inspection guide developed by a specialist department for nursing homes and institutions for the handicapped (Fachstelle für Pflege und Behinderteneinrichtungen, FQA). Because inspections are performed in multiprofessional teams, it makes sense to use a coordinated inspection catalog. The aim was to integrate hygienic requirements specified in the Bavarian guidelines for hygiene by the LGL into the inspection guide published by the FQA to obtain a quality assured surveillance. The involved parties were questioned about the inspection guide and their hygiene management and then the hygiene criteria of the LGL were implemented into the inspection guide. Questions dealing with hygiene requirements concerning intensive care, management of multidrug resistant bacteria and interviews with the person responsible for infection control in the facility itself were developed for the first time and were integrated into the inspection guide. The revised inspection guide was tested for its applicability. With the revised inspection guide there now exists a tool which allows not only comprehensive inspections of the facilities including hygiene issues but also a good cooperation of the various parties involved. There are many actions which have to be conveyed into the future, especially programs to train staff to apply the inspection guide and to enhance the ability of all participants to act in cooperation. The guide will also allow the facilities to cooperate more easily and more closely, as the guide takes the respective problems and challenges of the different facilities into consideration. Additionally the

  9. Facile synthesis of symmetrical bis(benzhydryl)ethers using p-toluenesulfonyl chloride under solvent-free conditions

    Science.gov (United States)

    2013-01-01

    Background The benzhydryl ether moiety is widely distributed in nature and constitutes a key structural motif in numerous molecules of significant biological potential and of prospective clinical uses. Solvent-free and cost-effective facile synthesis of symmetrical bis(benzhydryl)ethers is, thus, much desirable. Results A simple and efficient method for the facile synthesis of symmetrical bis(benzhydryl)ethers directly from the corresponding benzhydrols has been developed using a catalytic amount of p-toluenesulfonyl chloride (5 mol%) at an oil bath temperature of 110°C under solvent-free conditions. Conclusions Operational simplicity, low reagent loading, high product yields, short reaction time, and solvent-free conditions are the notable advantages of the present method. PMID:23414667

  10. University of the Witwatersrand physiotherapy undergraduate curriculum alignment to medical conditions of patients within Gauteng state health facilities

    Directory of Open Access Journals (Sweden)

    Mokgobadibe V. Ntsiea

    2017-02-01

    Full Text Available Background: The healthcare sector requires graduates with the ability to confidently assess and manage the majority of the medical conditions seen in hospitals.Objective: To establish whether the most prevalent medical conditions treated by physiotherapists in Gauteng (South Africa state health facilities align with the University of the Witwatersrand (Wits physiotherapy curriculum.Methods: This was a retrospective review of condition-related statistics from physiotherapy departments within the Gauteng province state health facilities. Data from all Gauteng government hospitals that had submitted at least 75% of their physiotherapy condition–related statistics to the provincial statistics coordinator from January 2012 to December 2014 were considered and compared to medical conditions covered in the Wits 2015 physiotherapy curriculum to check if all conditions listed in the Gauteng statistics appeared within the Wits curriculum document. The number of teaching hours for the common conditions was noted to check the emphasis given to these conditions in the curriculum.Results: Eighty-three per cent of the hospitals submitted 75% of their monthly statistics. Overall, the most common conditions treated were lower limb fractures (13% followed by stroke (7.6% (n = 705 597. Within the neuro-musculoskeletal category, the most common conditions after lower limb fractures were soft tissue injuries (15.1% (n = 330 511. The most common cardiopulmonary conditions were tuberculosis (24.9%, followed by pneumonia (13.8% (n = 94 895. The most common neurological conditions were stroke (30.9% followed by cerebral palsy (17% (n = 174 024. Within the non-specified categories, the number of intensive care unit (ICU patients was the highest (23%, followed by sputum induction (21% (n = 138 187. The most common conditions that were emphasised within the Wits curriculum as indicated by the teaching hours: fractures, 14.5 (66% of 22 third-year orthopaedics hours

  11. Facile synthesis of -C[double bond, length as m-dash]N- linked covalent organic frameworks under ambient conditions.

    Science.gov (United States)

    Ding, San-Yuan; Cui, Xiao-Hui; Feng, Jie; Lu, Gongxuan; Wang, Wei

    2017-10-20

    We reported herein a facile approach for the synthesis of -C[double bond, length as m-dash]N- linked covalent organic frameworks under ambient conditions. Three known (COF-42, COF-43, and COF-LZU1) and one new (Pr-COF-42) COF materials were successfully synthesized using this method. Furthermore, this simple synthetic approach makes the large-scale synthesis of -C[double bond, length as m-dash]N- linked COFs feasible.

  12. Pre-feasibility analysis of powering a remote research facility under arid conditions in Kazakhstan

    Directory of Open Access Journals (Sweden)

    Sagimbayev Sagi

    2017-01-01

    Full Text Available This study evaluates the feasibility of using photovoltaic solar cells and solar water heating in a remote off-grid research facility for scientists in the steppe of Kazakhstan. The objective of the facility is to observe wildlife in this region, especially saiga antelope, whose population has been drastically reduced in recent years. The analysis is conducted using RETScreen software and includes energy, cost, emissions, and financial assessment. The proposed energy model is compared with a traditional base case scenario (based on a diesel boiler and reciprocating engine. Despite the challenges and constraints, the project pays off within its lifespan. It eliminates greenhouse gas emissions and reduces human interference with local wildlife.

  13. End State Condition Report for Materials and Fuels Complex Facilities MFC-799, 799A, and 770C

    Energy Technology Data Exchange (ETDEWEB)

    Gary Mecham

    2010-10-01

    The Materials and Fuels Complex (MFC) facilities MFC-799, “Sodium Processing Facility” (a single building consisting of two areas: the Sodium Process Area and the Carbonate Process Area); MFC-799A, “Caustic Storage Area;” and MFC-770C, “Nuclear Calibration Laboratory,” have been declared excess to future Department of Energy (DOE) Office of Nuclear Energy(NE) mission requirements. Transfer of these facilities from NE to the DOE Office of Environmental Management (EM), and an associated schedule for doing so, have been agreed upon by the two offices. This report documents the completion of pre-transfer stabilization actions, as identified in DOE Guide 430.1-5, “Transition Implementation Guide,” for buildings MFC-799/799A and 770C, and indicates that these facilities are ready for transfer from NE to EM. The facilities are in a known, safe condition and information is provided to support efficient decommissioning and demolition (D&D) planning while minimizing the possibility of encountering unforeseen circumstances during the D&D activities.

  14. Influence of facilities of ski preparation on the bodily condition of teenagers 11-12 years.

    Directory of Open Access Journals (Sweden)

    Vorona V.V.

    2011-04-01

    Full Text Available The indexes of bodily condition of teenagers were determined. A dynamics and increase of the explored indexes were analyzed in the process of ski preparation in the system of lessons of the physical culture of schoolchildren. The 156 teenagers at the age 11-12 years old took part in the experiment. The positive effect of ski training in the bodily condition of the investigated teenagers is proved. Reliable intercommunication was determined between the ski movements and indexes of bodily condition, which characterize work of the cardiovascular system.

  15. PROBLEMS OF DESIGN AND CONSTRUCTION OF UNDERGROUND AND TRANSPORT FACILITIES IN THE CONDITIONS OF BELARUS

    Directory of Open Access Journals (Sweden)

    V. A. Sernov

    2010-03-01

    Full Text Available The experience of design and erecting of underground and transport structures, fencing deep excavations in cramped urban conditions on the examples of various projects in the Republic of Belarusis presented in the paper.

  16. A Method for Monitoring Deposition at a Solid Cathode in an Electrorefiner for a Two-Species System Using Electrode Potentials

    Energy Technology Data Exchange (ETDEWEB)

    D.S. Rappleye; M.-S. Yim; M.F. Simpson; R.M. Cumberland

    2013-10-01

    Currently, process monitoring of spent nuclear fuel electrorefining relies upon sampling and destructive analysis methods coupled with extrapolative thermodynamic process models for non-interrupted operations. Corrections to those models are performed infrequently, jeopardizing both the control of the process and safeguarding of nuclear material. Furthermore, the timeliness of obtaining the results is inadequate for application of international safeguards protocol. Alternatively, a system that dynamically utilizes electrical data such as electrode potentials and cell current can hypothetically be used to achieve real-time process monitoring and more robust control as well as improved safeguards. Efforts to develop an advanced model of the electrorefiner to date have focused on a forward modeling approach by using feed and salt compositions to determine the product composition, cell current and electrode potential response. Alternatively, an inverse model was developed, and reported here, to predict the product deposition rates on a cathode using the cell current, cathode potential, and fundamental relations of electrochemistry. The model was applied to the following cases: pure uranium deposition, co-deposition of uranium and plutonium, and co-deposition of uranium and zirconium. The deposition rates predicted by the inverse model were compared to those of a forward model, ERAD.

  17. Electrorefining of copper from a cuprous ion complexing electrolyte. II. Experimental comparison of possible alternative electrolytes and preliminary cost engineering analysis

    Energy Technology Data Exchange (ETDEWEB)

    Brown, A.P.; Loutfy, R.O.; Cook, G.M.

    1980-04-01

    The energy saving potential and refining capability of three copper(I)/electrolyte systems for the electrorefining of copper were compared experimentally. The alternative electrolyte systems studied were copper(I)/acid chloride, copper(I)/acetonitrile and sulfuric acid, and copper(I)/ammonia solutions. These were compared to the conventional copper(II)/sulfuric acid electrolyte. All of the alternative electrolyte systems demonstrated at least some potential for saving energy when run at an equal deposition rate to the conventional process; the chloride electrolyte showed the greatest energy saving potential, about 70%, and the ammonia electrolyte showed the least, about 25%. All of the alternative electrolyte systems, however, exhibited performance problems, primarily with regard to inadequate separation of impurities. A preliminary capital cost estimate was made for the copper(I)/chloride system. This estimate showed that, for the alternative electrolyte system to be cost competitive (that is, a reduction of capital cost of about 15 to 20%) with the conventional electrorefining process, the refining cells would have to be operated at a current density of about 25 to 30 mA-cm/sup -2/. At this current density, the estimated energy saving potential for the copper(I)/chloride system was still about 50%.

  18. Feasibility Assessment of an ISS Artificial Gravity Conditioning Facility by Means of Multi-Body Approach

    Science.gov (United States)

    Toso, Mario; Baldesi, Gianluigi; Moratto, Claudio; De Wilde, Don; Bureo Dacal, Rafael; Castellsaguer, Joaquim

    2012-07-01

    Even though human exploration of Mars is a distant objective, it is well understood that, for human space voyages of several years duration, crews would be at risk of catastrophic consequences should any of the systems that provide adequate air, water, food, or thermal protection fail. Moreover, crews will face serious health and/or safety risks resulting from severe physiologic deconditioning associated with prolonged weightlessness. The principal ones are related to physical and functional deterioration of the regulation of the blood circulation, decreased aerobic capacity, impaired musculo-skeletal systems, and altered sensory- motor system performance. As the reliance of future space programmes on virtual modelling, simulation and justification has substantially grown together with the proto-flight hardware development approach, a range of simulation capabilities have become increasingly important in the requirements specification, design, verification, testing, launch and operation of new space systems. In this frame, multibody software is a key tool in providing a more coordinated and consistent approach from the preliminary development phases of the most complex systems. From a scientific prospective, an artificial gravity facility, such as the one evaluated in this paper, would be the first in-flight testing of the effectiveness and acceptability of short radius centrifuge as a countermeasure to human deconditioning on orbit. The ISS represents a unique opportunity to perform this research. From an engineering point of view, the preliminary assessment described in this paper, highlights the difficult engineering challenges of such a facility. The outcome proves that a human can be accommodated in the available volume, while respecting the human ergonomic basic requirements and preserving the global structural integrity of the hosting ISS module. In particular, analysis shows that, although the load capacity of the structural interfaces imposes a very low

  19. Validity of the RAI-MDS for ascertaining diabetes and comorbid conditions in long-term care facility residents.

    Science.gov (United States)

    Lix, Lisa M; Yan, Lin; Blackburn, David; Hu, Nianping; Schneider-Lindner, Verena; Teare, Gary F

    2014-01-15

    This study assessed the validity of the Resident Assessment Instrument Minimum Data Set (RAI-MDS) Version 2.0 for diagnoses of diabetes and comorbid conditions in residents of long-term care facilities (LTCFs). Hospital inpatient, outpatient physician billing, RAI-MDS, and population registry data for 1997 to 2011 from Saskatchewan, Canada were used to ascertain cases of diabetes and 12 comorbid conditions. Prevalence estimates were calculated for both RAI-MDS and administrative health data. Sensitivity, specificity, and positive and negative predictive values (PPV and NPV) were calculated using population-based administrative health data as the validation data source. Cohen's κ was used to estimate agreement between the two data sources. 23,217 LTCF residents were in the diabetes case ascertainment cohort. Diabetes prevalence was 25.3% in administrative health data and 21.9% in RAI-MDS data. Overall sensitivity of a RAI-MDS diabetes diagnoses was 0.79 (95% CI: 0.79, 0.80) and the PPV was 0.92 (95% CI: 0.91, 0.92), when compared to administrative health data. Sensitivity of the RAI-MDS for ascertaining comorbid conditions ranged from 0.21 for osteoporosis to 0.92 for multiple sclerosis; specificity was high for most conditions. RAI-MDS clinical assessment data are sensitive to ascertain diabetes cases in LTCF populations when compared to administrative health data. For many comorbid conditions, RAI-MDS data have low validity when compared to administrative data. Risk-adjustment measures based on these comorbidities might not produce consistent results for RAI-MDS and administrative health data, which could affect the conclusions of studies about health outcomes and quality of care across facilities.

  20. Testing facility for hydrogen storage materials designed to simulate application based conditions

    NARCIS (Netherlands)

    Westerwaal, R.J.; Nyqvist, R.G.; Haije, W.G.

    2011-01-01

    For the daily use of hydrogen storage materials, not only their intrinsic storage properties are important, but also equally important is the performance under practical conditions. Besides the techniques already available for the fundamental characterization of storage materials, there is a growing

  1. [Working conditions and professional risk for operational personnel of energy facilities].

    Science.gov (United States)

    Amirov, N Kh; Ilyukhin, N E; Rusin, M N; Krasnoshchekova, V N

    2013-01-01

    Features of working conditions and a state of health of operation personnel of the network companies of power industry were studied for the purpose of justification and introduction of preventive actions for the decrease in influence of factors of professional risk.

  2. Stratosphere Conditions Inactivate Bacterial Endospores from a Mars Spacecraft Assembly Facility

    Science.gov (United States)

    Khodadad, Christina L.; Wong, Gregory M.; James, Leandro M.; Thakrar, Prital J.; Lane, Michael A.; Catechis, John A.; Smith, David J.

    2017-04-01

    Every spacecraft sent to Mars is allowed to land viable microbial bioburden, including hardy endospore-forming bacteria resistant to environmental extremes. Earth's stratosphere is severely cold, dry, irradiated, and oligotrophic; it can be used as a stand-in location for predicting how stowaway microbes might respond to the martian surface. We launched E-MIST, a high-altitude NASA balloon payload on 10 October 2015 carrying known quantities of viable Bacillus pumilus SAFR-032 (4.07 × 107 spores per sample), a radiation-tolerant strain collected from a spacecraft assembly facility. The payload spent 8 h at ˜31 km above sea level, exposing bacterial spores to the stratosphere. We found that within 120 and 240 min, spore viability was significantly reduced by 2 and 4 orders of magnitude, respectively. By 480 min, <0.001% of spores carried to the stratosphere remained viable. Our balloon flight results predict that most terrestrial bacteria would be inactivated within the first sol on Mars if contaminated spacecraft surfaces receive direct sunlight. Unfortunately, an instrument malfunction prevented the acquisition of UV light measurements during our balloon mission. To make up for the absence of radiometer data, we calculated a stratosphere UV model and conducted ground tests with a 271.1 nm UVC light source (0.5 W/m2), observing a similarly rapid inactivation rate when using a lower number of contaminants (640 spores per sample). The starting concentration of spores and microconfiguration on hardware surfaces appeared to influence survivability outcomes in both experiments. With the relatively few spores that survived the stratosphere, we performed a resequencing analysis and identified three single nucleotide polymorphisms compared to unexposed controls. It is therefore plausible that bacteria enduring radiation-rich environments (e.g., Earth's upper atmosphere, interplanetary space, or the surface of Mars) may be pushed in evolutionarily consequential directions.

  3. Stratosphere Conditions Inactivate Bacterial Endospores from a Mars Spacecraft Assembly Facility.

    Science.gov (United States)

    Khodadad, Christina L; Wong, Gregory M; James, Leandro M; Thakrar, Prital J; Lane, Michael A; Catechis, John A; Smith, David J

    2017-04-01

    Every spacecraft sent to Mars is allowed to land viable microbial bioburden, including hardy endospore-forming bacteria resistant to environmental extremes. Earth's stratosphere is severely cold, dry, irradiated, and oligotrophic; it can be used as a stand-in location for predicting how stowaway microbes might respond to the martian surface. We launched E-MIST, a high-altitude NASA balloon payload on 10 October 2015 carrying known quantities of viable Bacillus pumilus SAFR-032 (4.07 × 10 7 spores per sample), a radiation-tolerant strain collected from a spacecraft assembly facility. The payload spent 8 h at ∼31 km above sea level, exposing bacterial spores to the stratosphere. We found that within 120 and 240 min, spore viability was significantly reduced by 2 and 4 orders of magnitude, respectively. By 480 min, Mars if contaminated spacecraft surfaces receive direct sunlight. Unfortunately, an instrument malfunction prevented the acquisition of UV light measurements during our balloon mission. To make up for the absence of radiometer data, we calculated a stratosphere UV model and conducted ground tests with a 271.1 nm UVC light source (0.5 W/m 2 ), observing a similarly rapid inactivation rate when using a lower number of contaminants (640 spores per sample). The starting concentration of spores and microconfiguration on hardware surfaces appeared to influence survivability outcomes in both experiments. With the relatively few spores that survived the stratosphere, we performed a resequencing analysis and identified three single nucleotide polymorphisms compared to unexposed controls. It is therefore plausible that bacteria enduring radiation-rich environments (e.g., Earth's upper atmosphere, interplanetary space, or the surface of Mars) may be pushed in evolutionarily consequential directions. Key Words: Planetary protection-Stratosphere-Balloon-Mars analog environment-E-MIST payload-Bacillus pumilus SAFR-032. Astrobiology 17, 337-350.

  4. Defense Facility Condition: Revised Guidance Needed to Improve Oversight of Assessments and Ratings

    Science.gov (United States)

    2016-06-01

    and repair amounts could change in future financial statements as the services complete implementation of the standardized process. Separate from...and financial reports; interviewed installation officials; and held 16 focus groups at a non-generalizable sample of eight U.S. installations...are to implement the standardized process in part by assessing the condition of buildings, pavement, and rail using the same set of software tools

  5. Replenishment policy for non-instantaneous deteriorating items in a two storage facilities under inflationary conditions

    Directory of Open Access Journals (Sweden)

    Chandra K. Jaggi

    2016-06-01

    Full Text Available The present study investigates an inventory model for non-instantaneous deteriorating items under inflationary conditions with partially backlogged shortages. In today’s market structure consumers are looking for goods for which there is a delay in deterioration. At the same time, the consumers’ willingness to wait has been decreased over time, which leads to lost sales. Moreover in financial decision-making, the effects of inflation and time value of money cannot be oblivious to an inventory system. In this scenario, managing inventory of goods remains a challenging task for the decision makers, who may also have to rent warehouse under different prevailing factors such as, bulk discount, limited space in the retail outlet, or increasing inflation rates. With a focus on reduction of costs and increasing customer service, warehouse decision models are crucial for an organization’s profitability. Hence a mathematical model has been developed in the view of above scenario, in order to determine the optimal policy for the decision maker, by minimizing the present worth of total cost. The optimization procedure has been illustrated by a numerical example and detailed sensitivity analysis of the optimal solution has been performed to showcase the effect of various parameters. Managerial implications has also been presented to aid the decision making process.

  6. Modeling Stimulated Raman Scattering in Direct-Drive Inertial Confinement Fusion Plasmas for National Ignition Facility Conditions

    Science.gov (United States)

    Maximov, A. V.; Shaw, J. G.; Myatt, J. F.; Short, R. W.

    2017-10-01

    In the plasmas of direct-drive inertial confinement fusion (ICF), the coupling of laser power to the target plasma is strongly influenced by the laser-plasma interaction (LPI) processes driven by multiple crossing laser beams. For the plasma parameters relevant to the conditions of the experiments at the National Ignition Facility (NIF), the threshold of the stimulated Raman scattering (SRS) is usually well exceeded because of the large scale length of the plasma density, making the study of SRS vital for the NIF ICF program. The SRS evolution starts as a convective or absolute instability, and the nonlinear saturation is determined by the ion-acoustic perturbations and kinetic effects. The LPI processes of cross-beam energy transfer and two-plasmon decay also drive the ion-acoustic modes and their interplay with SRS is analyzed. This work was supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  7. Infection control assessment after an influenza outbreak in a residential care facility for children and young adults with neurologic and neurodevelopmental conditions.

    Science.gov (United States)

    Azofeifa, Alejandro; Yeung, Lorraine F; Peacock, Georgina; Moore, Cynthia A; Rodgers, Loren; DiOrio, Mary; Page, Shannon L; Fowler, Brian; Stone, Nimalie D; Finelli, Lyn; Jhung, Michael A

    2013-07-01

    To assess the knowledge, attitudes, and practices of infection control among staff in a residential care facility for children and young adults with neurologic and neurodevelopmental conditions. Self-administered survey. Residential care facility (facility A). Facility A staff ([Formula: see text]). We distributed a survey to staff at facility A. We classified staff with direct care responsibilities as clinical (ie, physicians, nurses, and therapists) or nonclinical (ie, habilitation assistants, volunteers, and teachers) and used χ(2) tests to measure differences between staff agreement to questions. Of 248 surveys distributed, 200 (81%) were completed; median respondent age was 36 years; 85% were female; and 151 were direct care staff (50 clinical, 101 nonclinical). Among direct care staff respondents, 86% agreed they could identify residents with respiratory symptoms, 70% stayed home from work when ill with respiratory infection, 64% agreed that facility administration encouraged them to stay home when ill with respiratory infection, and 72% reported that ill residents with respiratory infections were separated from well residents. Clinical and nonclinical staff differed in agreement about using waterless hand gel as a substitute for handwashing (96% vs 78%; [Formula: see text]) and whether handwashing was done after touching residents (92% vs 75%; [Formula: see text]). Respondents' knowledge, attitudes, and practices regarding infection control could be improved, especially among nonclinical staff. Facilities caring for children and young adults with neurologic and neurodevelopmental conditions should encourage adherence to infection control best practices among all staff having direct contact with residents.

  8. Study of the influence of the operation of the unloading facility on the hydraulic conditions in the installation for dry quenching of coke

    Energy Technology Data Exchange (ETDEWEB)

    Grishchenko, A.I.; Ereskovskii, O.S.; Lavrishchev, V.I.

    1981-01-01

    Theoretical studies are presented elucidating the occurrence of a dislocation of the normal pressure distribution along the circuit of the installation for dry quenching of coke in dependence on the conditions of operation of the unloading facility. An electrical model is proposed for the hydraulic conditions in the installation for dry quenching of coke, allowing a study of the aerodynamic conditions of operation of the installation to be performed on an analog computer with sufficient accuracy.

  9. Analysis of the process main variables influence in the rejection of the cathodes during copper electrorefining; Analisis de las principales variables de proceso que influyen en el rechazo de los catodos durante el electrorrefino del cobre

    Energy Technology Data Exchange (ETDEWEB)

    Cifuentes, G.; Vargas, C.; Simpson, J.

    2009-07-01

    An experimental circuit of copper electrorefining using three types of anodes coming from three different Chilean foundries: Hernan Videla Lira, Las Ventanas and El Teniente was used to simulate the electrorefining process. In this circuit the problem of the cathode rejection and the influence of some process variables in this phenomenon were studied. The variables analyzed were: electrolyte cell flow, solids in suspension, current density, lead doping in the anodes and density and particle size of the anodic slimes generated. The main results obtained from the experimental circuit were the following: the electrolyte flow doesn't affect significantly the cathodic rejection, an increase of current density produces a decrease of cathodic rejections, the presence of the solids in suspension causes cathodes outside of norm, and to bigger quantity of lead in the anodes smallest were the rejections. (Author) 20 refs.

  10. Sanitation facilities, hygienic conditions, and prevalence of acute diarrhea among under-five children in slums of Addis Ababa, Ethiopia: Baseline survey of a longitudinal study.

    Science.gov (United States)

    Adane, Metadel; Mengistie, Bezatu; Kloos, Helmut; Medhin, Girmay; Mulat, Worku

    2017-01-01

    In developing countries, children under the age of five years who live in slums are highly vulnerable to diarrhea. However, there is a paucity of information on the relationship between sanitation facilities and hygienic conditions to acute diarrhea among under-five children in slum areas of Addis Ababa, Ethiopia. Therefore, this study examines the sanitation facilities and hygienic conditions in the slums of Addis Ababa and identifies the main factors significantly associated with acute diarrhea among children aged 0-50 months in those slums. A community-based cross-sectional household survey was carried out between September and November 2014, that then served as the baseline survey of a longitudinal study. For this survey, 697 children aged 0-50 months were recruited from two slum districts in Addis Ababa. A pre-tested structured questionnaire and an observational checklist were used for data collection. Multivariable logistic regression analysis was used to identify sanitation facilities and hygiene-related factors that were significantly associated with acute diarrhea by controlling potential confounding effects of selected socio-demographic factors. Adjusted odds ratio (AOR) with corresponding 95% confidence interval (CI) was used to quantify the strength of association. The prevalence of acute diarrhea among children aged 0-50 months in the study area was 11.9% and 94.6% of the sanitation facilities were unimproved. Sharing of a sanitation facility by six or more households (AOR = 4.7; 95% CI: 2.4-9.4), proximity of sanitation facilities within 15 meters of homes (AOR = 6.6; 95% CI: 2.5-17.0), presence of feces (AOR = 3.9; 95% CI: 1.5-10.3) and flies (AOR = 2.5; 95% CI: 1.3-5.0) on the floor of and/or around sanitation facilities, and presence of uncollected garbage inside house compounds (AOR = 3.2; 95% CI: 1.2-8.4) were significantly associated with acute diarrhea. This study reveals the slum environment to be high risk for diarrhea due to close proximity

  11. Assessment of activity-based pyroprocess costs for an engineering-scale facility in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Ki; Ko, Won Il [Nuclear Fuel Cycle Analysis Department, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Bang, Sung Sig [Dept. of Business and Technology Management, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2015-12-15

    This study set the pyroprocess facility at an engineering scale as a cost object, and presented the cost consumed during the unit processes of the pyroprocess. For the cost calculation, the activity based costing (ABC) method was used instead of the engineering cost estimation method, which calculates the cost based on the conceptual design of the pyroprocess facility. The calculation results demonstrate that the pyroprocess facility's unit process cost is $194/kgHM for pretreatment, $298/kgHM for electrochemical reduction, $226/kgHM for electrorefining, and $299/kgHM for electrowinning. An analysis demonstrated that the share of each unit process cost among the total pyroprocess cost is as follows: 19% for pretreatment, 29% for electrochemical reduction, 22% for electrorefining, and 30% for electrowinning. The total unit cost of the pyroprocess was calculated at $1,017/kgHM. In the end, electrochemical reduction and the electrowinning process took up most of the cost, and the individual costs for these two processes was found to be similar. This is because significant raw material cost is required for the electrochemical reduction process, which uses platinum as an anode electrode. In addition, significant raw material costs are required, such as for Li3PO4, which is used a lot during the salt purification process.

  12. Assessment of activity-based pyroprocess costs for an engineering-scale facility in Korea

    Directory of Open Access Journals (Sweden)

    Sungki Kim

    2015-12-01

    Full Text Available This study set the pyroprocess facility at an engineering scale as a cost object, and presented the cost consumed during the unit processes of the pyroprocess. For the cost calculation, the activity based costing (ABC method was used instead of the engineering cost estimation method, which calculates the cost based on the conceptual design of the pyroprocess facility. The calculation results demonstrate that the pyroprocess facility's unit process cost is $194/kgHM for pretreatment, $298/kgHM for electrochemical reduction, $226/kgHM for electrorefining, and $299/kgHM for electrowinning. An analysis demonstrated that the share of each unit process cost among the total pyroprocess cost is as follows: 19% for pretreatment, 29% for electrochemical reduction, 22% for electrorefining, and 30% for electrowinning. The total unit cost of the pyroprocess was calculated at $1,017/kgHM. In the end, electrochemical reduction and the electrowinning process took up most of the cost, and the individual costs for these two processes was found to be similar. This is because significant raw material cost is required for the electrochemical reduction process, which uses platinum as an anode electrode. In addition, significant raw material costs are required, such as for Li3PO4, which is used a lot during the salt purification process.

  13. Future and present condition of waste treatment facilities for foundry; Chuzo kojo haikibutsu shori setsubi no genjo to shorai

    Energy Technology Data Exchange (ETDEWEB)

    Takada, M. [Shinto Kogyo Co. Ltd., Tokyo (Japan)

    1997-12-25

    The current state of waste disposal facilities in foundries is introduced, and the future way that it should be is investigated from the viewpoint of environmental management of manufacturing plants which is shifting from taking countermeasures for environmental conservation to giving priority to environmental conservation. As the methods for waste disposal, there are a case of reusing it to decrease the quantity of waste as far as possible and a case of converting it into valuable material for reuse by other industries as valuable material. In connection with the facilities for decreasing the quantity of generated waste, outlines are given on the recovery system for spilled sand, classifiers (sieve, air classifier), separators (magnetic separator, shot separator), sand reproducing system, humidifier, and granulators (briquette of turning, granulation of dust). As regards future disposal facilities, investigation must be made on the support facility for production so as to reduce waste generation as far as possible, facility which sort generated waste reliably for easy disposal, facility for material recycling, and facility for realizing zero emission. 5 refs., 5 figs., 5 tabs.

  14. The time-resolved and extreme conditions XAS (TEXAS) facility at the European Synchrotron Radiation Facility: the general-purpose EXAFS bending-magnet beamline BM23.

    Science.gov (United States)

    Mathon, O; Beteva, A; Borrel, J; Bugnazet, D; Gatla, S; Hino, R; Kantor, I; Mairs, T; Munoz, M; Pasternak, S; Perrin, F; Pascarelli, S

    2015-11-01

    BM23 is the general-purpose EXAFS bending-magnet beamline at the ESRF, replacing the former BM29 beamline in the framework of the ESRF upgrade. Its mission is to serve the whole XAS user community by providing access to a basic service in addition to the many specialized instruments available at the ESRF. BM23 offers high signal-to-noise ratio EXAFS in a large energy range (5-75 keV), continuous energy scanning for quick-EXAFS on the second timescale and a micro-XAS station delivering a spot size of 4 µm × 4 µm FWHM. It is a user-friendly facility featuring a high degree of automation, online EXAFS data reduction and a flexible sample environment.

  15. Methods, forms and facilities of professional preparation of teachers-tutors in the conditions of the controlled from distance form of teaching

    Directory of Open Access Journals (Sweden)

    Osadchiy V.V.

    2010-06-01

    Full Text Available The problems of professional preparation of teachers-tutors are studied. The features of application of methods are considered, forms and facilities of professional preparation of teachers-tutors in the conditions of the controlled from distance form of teaching. As expedient methods are selected: method of lecture, video trainings, interactive methods (role-playing, case studies, brainstorming, methods of reflection, control methods, exercises, laboratory method. By the forms of organization are electronic seminars, web-seminars, videos-seminars. By teaching facilities are electronic educational resources and services of network the Internet.

  16. Liquid Methane Conditioning Capabilities Developed at the NASA Glenn Research Center's Small Multi- Purpose Research Facility (SMiRF) for Accelerated Lunar Surface Storage Thermal Testing

    Science.gov (United States)

    Bamberger, Helmut H.; Robinson, R. Craig; Jurns, John M.; Grasl, Steven J.

    2011-01-01

    Glenn Research Center s Creek Road Cryogenic Complex, Small Multi-Purpose Research Facility (SMiRF) recently completed validation / checkout testing of a new liquid methane delivery system and liquid methane (LCH4) conditioning system. Facility checkout validation was conducted in preparation for a series of passive thermal control technology tests planned at SMiRF in FY10 using a flight-like propellant tank at simulated thermal environments from 140 to 350K. These tests will validate models and provide high quality data to support consideration of LCH4/LO2 propellant combination option for a lunar or planetary ascent stage.An infrastructure has been put in place which will support testing of large amounts of liquid methane at SMiRF. Extensive modifications were made to the test facility s existing liquid hydrogen system for compatibility with liquid methane. Also, a new liquid methane fluid conditioning system will enable liquid methane to be quickly densified (sub-cooled below normal boiling point) and to be quickly reheated to saturation conditions between 92 and 140 K. Fluid temperatures can be quickly adjusted to compress the overall test duration. A detailed trade study was conducted to determine an appropriate technique to liquid conditioning with regard to the SMiRF facility s existing infrastructure. In addition, a completely new roadable dewar has been procured for transportation and temporary storage of liquid methane. A new spherical, flight-representative tank has also been fabricated for integration into the vacuum chamber at SMiRF. The addition of this system to SMiRF marks the first time a large-scale liquid methane propellant test capability has been realized at Glenn.This work supports the Cryogenic Fluid Management Project being conducted under the auspices of the Exploration Technology Development Program, providing focused cryogenic fluid management technology efforts to support NASA s future robotic or human exploration missions.

  17. Development and use of a new burner rig facility to mimic service loading conditions of Ni-based single crystal superalloys

    Directory of Open Access Journals (Sweden)

    Mauget Florent

    2014-01-01

    Full Text Available Performing representative experiments of in-service operating conditions of Ni-based superalloys used as high pressure turbine blades in aeroengines is a challenging issue due to the complex environmental, mechanical and thermal solicitations encountered by those components. A new burner rig test facility called MAATRE (French acronym for Mechanics and Aerothermics of Cooled Turbine Blades has been developed at ENSMA – Pprime Institute to mimic as close as possible those operating conditions. This new test bench has been used to perform complex non-isothermal creep tests representative of thermomechanical solicitations seen by some sections of HP turbine blades during engine certification procedure.

  18. The Potential and Utilization of Unused Energy Sources for Large-Scale Horticulture Facility Applications under Korean Climatic Conditions

    Directory of Open Access Journals (Sweden)

    In Tak Hyun

    2014-07-01

    Full Text Available As the use of fossil fuel has increased, not only in construction, but also in agriculture due to the drastic industrial development in recent times, the problems of heating costs and global warming are getting worse. Therefore, introduction of more reliable and environmentally-friendly alternative energy sources has become urgent and the same trend is found in large-scale horticulture facilities. In this study, among many alternative energy sources, we investigated the reserves and the potential of various different unused energy sources which have infinite potential, but are nowadays wasted due to limitations in their utilization. In addition, we utilized available unused energy as a heat source for a heat pump in a large-scale horticulture facility and analyzed its feasibility through EnergyPlus simulation modeling. Accordingly, the discharge flow rate from the Fan Coil Unit (FCU in the horticulture facility, the discharge air temperature, and the return temperature were analyzed. The performance and heat consumption of each heat source were compared with those of conventional boilers. The result showed that the power load of the heat pump was decreased and thus the heat efficiency was increased as the temperature of the heat source was increased. Among the analyzed heat sources, power plant waste heat which had the highest heat source temperature consumed the least electric energy and showed the highest efficiency.

  19. conditions

    Directory of Open Access Journals (Sweden)

    M. Venkatesulu

    1996-01-01

    Full Text Available Solutions of initial value problems associated with a pair of ordinary differential systems (L1,L2 defined on two adjacent intervals I1 and I2 and satisfying certain interface-spatial conditions at the common end (interface point are studied.

  20. The Time-resolved and Extreme-conditions XAS (TEXAS) facility at the European Synchrotron Radiation Facility: the energy-dispersive X-ray absorption spectroscopy beamline ID24

    Science.gov (United States)

    Pascarelli, S.; Mathon, O.; Mairs, T.; Kantor, I.; Agostini, G.; Strohm, C.; Pasternak, S.; Perrin, F.; Berruyer, G.; Chappelet, P.; Clavel, C.; Dominguez, M. C.

    2016-01-01

    The European Synchrotron Radiation Facility has recently made available to the user community a facility totally dedicated to Time-resolved and Extreme-conditions X-ray Absorption Spectroscopy – TEXAS. Based on an upgrade of the former energy-dispersive XAS beamline ID24, it provides a unique experimental tool combining unprecedented brilliance (up to 1014 photons s−1 on a 4 µm × 4 µm FWHM spot) and detection speed for a full EXAFS spectrum (100 ps per spectrum). The science mission includes studies of processes down to the nanosecond timescale, and investigations of matter at extreme pressure (500 GPa), temperature (10000 K) and magnetic field (30 T). The core activities of the beamline are centered on new experiments dedicated to the investigation of extreme states of matter that can be maintained only for very short periods of time. Here the infrastructure, optical scheme, detection systems and sample environments used to enable the mission-critical performance are described, and examples of first results on the investigation of the electronic and local structure in melts at pressure and temperature conditions relevant to the Earth’s interior and in laser-shocked matter are given. PMID:26698085

  1. The Time-resolved and Extreme-conditions XAS (TEXAS) facility at the European Synchrotron Radiation Facility: the energy-dispersive X-ray absorption spectroscopy beamline ID24.

    Science.gov (United States)

    Pascarelli, S; Mathon, O; Mairs, T; Kantor, I; Agostini, G; Strohm, C; Pasternak, S; Perrin, F; Berruyer, G; Chappelet, P; Clavel, C; Dominguez, M C

    2016-01-01

    The European Synchrotron Radiation Facility has recently made available to the user community a facility totally dedicated to Time-resolved and Extreme-conditions X-ray Absorption Spectroscopy--TEXAS. Based on an upgrade of the former energy-dispersive XAS beamline ID24, it provides a unique experimental tool combining unprecedented brilliance (up to 10(14) photons s(-1) on a 4 µm × 4 µm FWHM spot) and detection speed for a full EXAFS spectrum (100 ps per spectrum). The science mission includes studies of processes down to the nanosecond timescale, and investigations of matter at extreme pressure (500 GPa), temperature (10000 K) and magnetic field (30 T). The core activities of the beamline are centered on new experiments dedicated to the investigation of extreme states of matter that can be maintained only for very short periods of time. Here the infrastructure, optical scheme, detection systems and sample environments used to enable the mission-critical performance are described, and examples of first results on the investigation of the electronic and local structure in melts at pressure and temperature conditions relevant to the Earth's interior and in laser-shocked matter are given.

  2. Recalculating the steady state conditions of the V-1000 zero-power facility at Kurchatov Institute using Monte Carlo and nodal diffusion codes

    Energy Technology Data Exchange (ETDEWEB)

    Sahlberg, Ville [VTT Technical Research Centre of Finland Ltd, VTT (Finland)

    2017-09-15

    Continuous-energy Monte Carlo reactor physics code Serpent 2 was used to model the critical steady state conditions measured in V-1000 zero-power critical facility at Kurchatov Institute (KI), Moscow in 1990-1992. The Serpent 2 results were compared to measurements and Serpent 2 was used to generate group constants for reactor dynamics code HEXTRAN. The results of a HEXTRAN calculation of the steady state were compared to Serpent 2. The relative power density distribution of the SERPENT2 calculations compared with the measurements was within the statistical accuracy. The comparison of HEXTRAN and Serpent 2 node-wise relative power density distributions showed an accuracy of ±10%.

  3. [The modular strategy for the informational support of medical activities based at the spa and health resort facilities under conditions of infrastructure deficit].

    Science.gov (United States)

    Yezhov, V V; Goldberg, D L; Grigorev, P E; Mizin, V I; Olenchuk, A V; Vasilieva, I V

    2017-12-05

    The Crimean peninsula, by virtue of its unique geographical conditions, has a variety of natural resources providing a basis for the maintenance of the health resort activities in the region. However, most local health centers suffer from the chronic and difficultly avoidable in the short term problems with logistical support, including the shortage of computers and the lack of modern network infrastructure. This circumstance limits the deployment capabilities of high-grade medical information systems for the automation of all components of the activity of health resorts and the significant improvement of the performance of other aspects of their work, such as efficient patient routing, workflow optimization, limiting the opportunities for the realization of certain corruption schemes by the staff. We have studied the routing of patients and the associated document flow in a number of Crimean spa and health resort facilities (sanatoriums). As a result, the basic work places at which information contained in the documents is undergoing changes were identified. Based on these data, the basic (modular) concept of the development of medical information system was formulated. According to the principle of modularity, the structure of the information system has been modified and optimized. The stages of implementation of this approach at various levels of logistic facilities were described, defined and justified. The key feature of the proposed system consists in that even the minimal equipment of computing infrastructure units (starting from a single workplace, such as a «medical receptionist») may be sufficient to achieve the significant degree of automation in the workflow, provide monitoring and analysis of the medical records of the spa and health resort facilities. By gradually increasing the number of related automated workplaces and modules, it is possible to expand the capabilities of the system up to the full automation of a given health resort facility.

  4. Selective N-alkylation of amines using nitriles under hydrogenation conditions: facile synthesis of secondary and tertiary amines.

    Science.gov (United States)

    Ikawa, Takashi; Fujita, Yuki; Mizusaki, Tomoteru; Betsuin, Sae; Takamatsu, Haruki; Maegawa, Tomohiro; Monguchi, Yasunari; Sajiki, Hironao

    2012-01-14

    Nitriles were found to be highly effective alkylating reagents for the selective N-alkylation of amines under catalytic hydrogenation conditions. For the aromatic primary amines, the corresponding secondary amines were selectively obtained under Pd/C-catalyzed hydrogenation conditions. Although the use of electron poor aromatic amines or bulky nitriles showed a lower reactivity toward the reductive alkylation, the addition of NH(4)OAc enhanced the reactivity to give secondary aromatic amines in good to excellent yields. Under the same reaction conditions, aromatic nitro compounds instead of the aromatic primary amines could be directly transformed into secondary amines via a domino reaction involving the one-pot hydrogenation of the nitro group and the reductive alkylation of the amines. While aliphatic amines were effectively converted to the corresponding tertiary amines under Pd/C-catalyzed conditions, Rh/C was a highly effective catalyst for the N-monoalkylation of aliphatic primary amines without over-alkylation to the tertiary amines. Furthermore, the combination of the Rh/C-catalyzed N-monoalkylation of the aliphatic primary amines and additional Pd/C-catalyzed alkylation of the resulting secondary aliphatic amines could selectively prepare aliphatic tertiary amines possessing three different alkyl groups. According to the mechanistic studies, it seems reasonable to conclude that nitriles were reduced to aldimines before the nucleophilic attack of the amine during the first step of the reaction.

  5. Effects of wastewater effluent discharge and treatment facility upgrades on environmental and biological conditions of Indian Creek, Johnson County, Kansas, June 2004 through June 2013

    Science.gov (United States)

    Graham, Jennifer L.; Stone, Mandy L.; Rasmussen, Teresa J.; Foster, Guy M.; Poulton, Barry C.; Paxson, Chelsea R.; Harris, Theodore D.

    2014-01-01

    Indian Creek is one of the most urban drainage basins in Johnson County, Kansas, and environmental and biological conditions of the creek are affected by contaminants from point and other urban sources. The Johnson County Douglas L. Smith Middle Basin (hereafter referred to as the “Middle Basin”) and Tomahawk Creek Wastewater Treatment Facilities (WWTFs) discharge to Indian Creek. In summer 2010, upgrades were completed to increase capacity and include biological nutrient removal at the Middle Basin facility. There have been no recent infrastructure changes at the Tomahawk Creek facility; however, during 2009, chemically enhanced primary treatment was added to the treatment process for better process settling before disinfection and discharge with the added effect of enhanced phosphorus removal. The U.S. Geological Survey, in cooperation with Johnson County Wastewater, assessed the effects of wastewater effluent on environmental and biological conditions of Indian Creek by comparing two upstream sites to four sites located downstream from the WWTFs using data collected during June 2004 through June 2013. Environmental conditions were evaluated using previously and newly collected discrete and continuous data and were compared with an assessment of biological community composition and ecosystem function along the upstream-downstream gradient. This study improves the understanding of the effects of wastewater effluent on stream-water and streambed sediment quality, biological community composition, and ecosystem function in urban areas. After the addition of biological nutrient removal to the Middle Basin WWTF in 2010, annual mean total nitrogen concentrations in effluent decreased by 46 percent, but still exceeded the National Pollutant Discharge Elimination System (NPDES) wastewater effluent permit concentration goal of 8.0 milligrams per liter (mg/L); however, the NPDES wastewater effluent permit total phosphorus concentration goal of 1.5 mg/L or less was

  6. Uniform, stable, and efficient planar-heterojunction perovskite solar cells by facile low-pressure chemical vapor deposition under fully open-air conditions.

    Science.gov (United States)

    Luo, Paifeng; Liu, Zhaofan; Xia, Wei; Yuan, Chenchen; Cheng, Jigui; Lu, Yingwei

    2015-02-04

    Recently, hybrid perovskite solar cells (PSCs) have attracted extensive attention due to their high efficiency and simple preparing process. Herein, a facile low-pressure chemical vapor deposition (LPCVD) technology is first developed to fabricate PSCs, which can effectively reduce the over-rapid intercalating reaction rate and easily overcome this blocking issue during the solution process. As a result, the prepared uniform perovskite films exhibit good crystallization, strong absorption, and long carrier diffusion length. More strikingly, CH3NH3PbI3 absorbers by LPCVD demonstrate excellent moisture-resistant feature even under laser illumination and high-temperature conditions, which indicates that our proprietary method is very suitable for the future low-cost, nonvacuum production of the new generation photovoltaic devices. Finally, high efficiency of 12.73% is successfully achieved under fully open-air conditions. To the best of our knowledge, this is the first report of efficient PSCs with such a high humidity above 60%.

  7. A Facile Synthesis of N-H- and N-Substituted Acridine-1,8-diones under Sonic Condition

    Directory of Open Access Journals (Sweden)

    S. Sudha

    2013-01-01

    Full Text Available Synthesis of an assembly of structurally important N-H- and N-substituted acridine-1,8-diones by CAN (ceric ammonium nitrate catalysed one-pot four-component reaction of electron-deficient and electron-rich aromatic aldehydes and aromatic amines or ammonium acetate and dimedone or cyclohexyl-1,3-diones at 26°C under sonic condition is reported. The method is clean and energy efficient as it uses a greener method and an eco-friendly catalyst.

  8. Efficient and facile one pot carboxylation of multiwalled carbon nanotubes by using oxidation with ozone under mild conditions

    Science.gov (United States)

    Naeimi, Hossein; Mohajeri, Ali; Moradi, Leila; Rashidi, Ali Morad

    2009-11-01

    In this study, oxidation of carbon nanotubes with ozone in the presence of hydrogen peroxide was investigated. The reaction was performed under clean and mild conditions and oxidized products with high concentration of oxygenated groups were yielded. The reaction products were characterized with attenuated total reflectance (ATR), Raman spectroscopy, scanning electron microscopy (SEM), X-ray diffractometry (XRD), back titration, X-ray photoelectron spectroscopy (XPS) and the dispersion behavior of the oxidized multiwalled carbon nanotubes (MWCNTs) was also studied. The results confirmed the presence of high concentrations of oxidative groups on the carbon nanotubes (CNTs) treated by the method of the present work.

  9. Efficient and facile one pot carboxylation of multiwalled carbon nanotubes by using oxidation with ozone under mild conditions

    Energy Technology Data Exchange (ETDEWEB)

    Naeimi, Hossein, E-mail: naeimi@kashanu.ac.ir [Department of Chemistry, Faculty of Science, University of Kashan, 87317 Kashan (Iran, Islamic Republic of); Mohajeri, Ali [West Blvd. Olympic Village Blvd. Azadi Sports Complex, Gas Division, Research Institute of Petroleum Industry (RIPI), P.O. Box 14665-1998, Tehran (Iran, Islamic Republic of); Moradi, Leila [Department of Chemistry, Faculty of Science, University of Kashan, 87317 Kashan (Iran, Islamic Republic of); Rashidi, Ali Morad [West Blvd. Olympic Village Blvd. Azadi Sports Complex, Gas Division, Research Institute of Petroleum Industry (RIPI), P.O. Box 14665-1998, Tehran (Iran, Islamic Republic of)

    2009-11-15

    Graphical abstract: In this work, oxidation of carbon nanotubes with ozone in the presence of hydrogen peroxide was studied. The reactions were performed under clean and mild conditions and oxidized products with high concentration of oxygenated groups were yielded. The reaction products were characterized with attenuated total reflectance (ATR), Raman spectroscopy, scanning electron microscopy (SEM), X-ray diffractometry (XRD), back titration, X-ray photoelectron spectroscopy (XPS) and the dispersion behavior of the oxidized multiwalled carbon nanotubes (MWCNTs) was also studied. The results confirmed the presence of high concentrations of oxidative groups on the carbon nanotubes (CNTs) treated by the method of the present work.

  10. Investigation of Thermal Comfort Conditions in Higher Education Facilities: A Case Study for Engineering Faculty in Edirne

    Directory of Open Access Journals (Sweden)

    E. Mıhlayanlar

    2017-02-01

    Full Text Available In this study, a higher education institution in Edirne (Trakya University Engineering Faculty is investigated for indoor thermal comfort conditions of the classrooms (indoor temperature, relative humidity, average radiant temperature, “Satisfaction from thermal environment” (PMV and “Dissatisfaction from thermal environment” (PPD. The classrooms in the institution are heated by a central heating system and utilise natural ventilation system. Measurements were taken with the proper devices at the same time of the weekdays during lecture times in winter (heating season in December. The results obtained from measurements are given in graphics and compared with the values given in ASHRAE 55 and ISO 7730 standards.

  11. A new experimental facility for investigating the formation and properties of gas hydrates under simulated seafloor conditions

    Energy Technology Data Exchange (ETDEWEB)

    Phelps, Tommy J.; Peters, David J.; Marshall, Simon L.; West, Olivia R.; Liang, Liyuan; Blencoe, James G.; Alexiades, Vasilios; Jacobs, Gary K.; Naney, Michael T.; Heck, Jack L.

    2001-02-01

    A seafloor process simulator (SPS) has been developed for experimental investigations of the physical, geochemical, and microbiological processes affecting the formation and stability of methane and carbon dioxide hydrates at temperatures and pressures corresponding to ocean depths of 2 km. The SPS is a corrosion-resistant pressure vessel whose salient characteristics are: (i) an operating range suitable for study of methane and carbon dioxide hydrates; (ii) numerous access and observation ports, and (iii) a large (0.0722 m3) internal volume. Initial experiments have shown that the SPS can be used to produce large amounts of high-purity methane hydrate over a wide range of experimental conditions.

  12. Facile synthesis of 1-naphthol azo dyes with nano SiO2/HIO4 under solvent-free conditions

    Directory of Open Access Journals (Sweden)

    A.R. Pourali

    2013-09-01

    Full Text Available Nano-silica supported periodic acid (nano-SPIA has been utilized as a heterogeneous reagent for a highly efficient and one pot synthesis of azo dyes based on 1-naphthol under solvent-free conditions at room temperature. This method has some advantages, the reaction workup is very easy and the catalyst can be easily separated from the reaction mixture and one-pot procedure. The related products have been obtained in good to excellent yields, high purity and short reaction times. The structures of the products have been characterized by several techniques using UV-Vis, FT-IR, 1H NMR, 13C NMR and mass spectra.DOI: http://dx.doi.org/10.4314/bcse.v27i3.13

  13. Analysis of Unit Process Cost for an Engineering-Scale Pyroprocess Facility Using a Process Costing Method in Korea

    Directory of Open Access Journals (Sweden)

    Sungki Kim

    2015-08-01

    Full Text Available Pyroprocessing, which is a dry recycling method, converts spent nuclear fuel into U (Uranium/TRU (TRansUranium metal ingots in a high-temperature molten salt phase. This paper provides the unit process cost of a pyroprocess facility that can process up to 10 tons of pyroprocessing product per year by utilizing the process costing method. Toward this end, the pyroprocess was classified into four kinds of unit processes: pretreatment, electrochemical reduction, electrorefining and electrowinning. The unit process cost was calculated by classifying the cost consumed at each process into raw material and conversion costs. The unit process costs of the pretreatment, electrochemical reduction, electrorefining and electrowinning were calculated as 195 US$/kgU-TRU, 310 US$/kgU-TRU, 215 US$/kgU-TRU and 231 US$/kgU-TRU, respectively. Finally the total pyroprocess cost was calculated as 951 US$/kgU-TRU. In addition, the cost driver for the raw material cost was identified as the cost for Li3PO4, needed for the LiCl-KCl purification process, and platinum as an anode electrode in the electrochemical reduction process.

  14. Determination of Fissile Loadings onto Monosodium Titanate (MST) under Conditions Relevant to the Actinide Removal Process Facility

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T

    2005-11-15

    This report describes the results of an experimental study to measure the sorption of fissile actinides on monosodium titanate (MST) at conditions relevant to operation of the Actinide Removal Process (ARP). The study examined the effect of a single contact of a large volume of radionuclide-spiked simulant solution with a small mass of MST. The volume of simulant to MST (8.5 L to 0.2 g of MST solids) was designed to mimic the maximum phase ratio that occurs between the multiple contacts of MST and waste solution and washing of the accumulated solids cycle of ARP. This work provides the following results. (1) After a contact time of {approx}2 weeks, we measured the following actinide loadings on the MST (average of solution and solids data), Pu: 2.79 {+-} 0.197 wt %, U: 14.0 {+-} 1.04 wt %, and Np: 0.839 {+-} 0.0178 wt %. (2) The plutonium and uranium loadings reported above are considerably higher than previously reported values. The higher loading result from the very high phase ratio and the high initial mass concentrations of uranium and plutonium. A separate upcoming document details the predicted values for this system versus the results. (3) The strontium DF values measured in these tests proved much lower than those reported previously with simulants having the same bulk chemical composition. The low strontium DF values reflect the very low initial mass concentration of strontium in this simulant (<100 {micro}g/L) compared to that in previous testing (> 600 {micro}g/L).

  15. Test of divertor materials under simulated ITER plasma disruption conditions using the hot plasma stream of the 2MK-200 facility

    Energy Technology Data Exchange (ETDEWEB)

    Arkhipov, N.I.; Bakhtin, V.; Konkashbaev, I. [Troitsk Inst. for Innovation and Fusion Research (Russian Federation)] [and others

    1994-12-31

    The high divertor heat load during tokamak plasma disruption results in sudden evaporation of a thin layer of divertor plate material, which acts as vapor shield and protects the target from further excessive evaporation. Formation and effectiveness of the vapor shield and material erosion are experimentally investigated at the 2MK-200 facility under conditions simulating the thermal quench phase of ITER tokamak plasma disruptions. Material samples from graphite, tungsten, boron nitrite and quartz were exposed to deuterium plasma streams with the following parameters: density < 10{sup 16}cm{sup {minus}3}, temperature T{sub e}+T{sub i} < 0.8 keV, plasma beta 0.25, plasma flow width 2 cm, power density 10 MW/cm{sup 2} and time duration of the pulse 20 {mu}s.

  16. Large-scale experimental facility for emergency condition investigation of a new generation NPP WWER-640 reactor with passive safety systems

    Energy Technology Data Exchange (ETDEWEB)

    Aniskevich, Y.N.; Vasilenko, V.A.; Zasukha, V.K.; Migrov, Y.A.; Khabensky, V.B. [Research Inst. of Technology NITI (Russian Federation)

    1997-12-31

    The creation of the large-scale integral experimental facility (KMS) is specified by the programme of the experimental investigations to justify the engineering decisions on the safety of the design of the new generation NPP with the reactor WWER-640. The construction of KMS in a full volume will allow to conduct experimental investigations of all physical phenomena and processes, practically, occurring during the accidents on the NPPs with the reactor of WWER type and including the heat - mass exchange processes with low rates of the coolant, which is typical during the utilization of the passive safety systems, process during the accidents with a large leak, and also the complex intercommunicated processes in the reactor unit, passive safety systems and in the containment with the condition of long-term heat removal to the final absorber. KMS is being constructed at the Research Institute of Technology (NITI), Sosnovy Bor, Leningrad region, Russia. (orig.). 5 refs.

  17. Heated Tube Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Heated Tube Facility at NASA GRC investigates cooling issues by simulating conditions characteristic of rocket engine thrust chambers and high speed airbreathing...

  18. Don't ask me what's the matter, ask me what matters: Acute mental health facility experiences of people living with autism spectrum conditions.

    Science.gov (United States)

    Maloret, P; Scott, T

    2017-10-27

    WHAT IS KNOWN ON THE SUBJECT?: There is a growing body of evidence that many people with an autism spectrum condition suffer anxiety in their daily life and a realization among practitioners that admission to a mental health unit for this population is usually a negative anxiety-inducing experience. Anxiety is driven by the intolerance of uncertainty that is being unsure of what is going to happen, how long the uncertainty will exist and the insistence of sameness which, when compromised, can be anxiety provoking. Equally, confusion in understanding personal emotional responses and those of others is a source of anxiety. WHAT THIS PAPER ADDS TO EXISTING KNOWLEDGE?: This paper builds upon existing understanding of anxiety as a causative factor of mental ill-health for people with an autism spectrum condition. Specifically, this paper explores the potentially anxiety-inducing experience of mental health unit admission; how anxiety is felt, triggered, expressed and managed. WHAT ARE THE IMPLICATIONS FOR PRACTICE?: As many different anxiety responses could be exhibited during hospitalization, including violent acts and self-harming, for mental health practitioners working in the inpatient units, it is essential that the thoughts, feelings and responses of the patient with an autistic spectrum condition (ASC) are better understood and that support offered during their stay in a mental health facility is from an informed position. Background This qualitative study explored how mental health inpatients with autistic spectrum conditions (ASCs) experience and cope with anxiety when admitted to an acute mental health inpatient facility in the United Kingdom. Anxiety is a common characteristic for people who live with ASCs and whilst a plethora of studies on anxiety in this population is published which correlate anxiety with mental health service experience, little is known about the actual triggers of anxiety and its manifestations. This study adds to a body of evidence

  19. The Utilization of Plant Facilities on the International Space Station—The Composition, Growth, and Development of Plant Cell Walls under Microgravity Conditions

    Directory of Open Access Journals (Sweden)

    Ann-Iren Kittang Jost

    2015-01-01

    Full Text Available In the preparation for missions to Mars, basic knowledge of the mechanisms of growth and development of living plants under microgravity (micro-g conditions is essential. Focus has centered on the g-effects on rigidity, including mechanisms of signal perception, transduction, and response in gravity resistance. These components of gravity resistance are linked to the evolution and acquisition of responses to various mechanical stresses. An overview is given both on the basic effect of hypergravity as well as of micro-g conditions in the cell wall changes. The review includes plant experiments in the US Space Shuttle and the effect of short space stays (8–14 days on single cells (plant protoplasts. Regeneration of protoplasts is dependent on cortical microtubules to orient the nascent cellulose microfibrils in the cell wall. The space protoplast experiments demonstrated that the regeneration capacity of protoplasts was retarded. Two critical factors are the basis for longer space experiments: a. the effects of gravity on the molecular mechanisms for cell wall development, b. the availability of facilities and hardware for performing cell wall experiments in space and return of RNA/DNA back to the Earth. Linked to these aspects is a description of existing hardware functioning on the International Space Station.

  20. Use of chlorofluorocarbon-based refrigerants in USArmy facility air-conditioning and refrigeration systems: Recommendations for the interim period 1994-2000

    Science.gov (United States)

    Sohn, Chang W.; Homan, Kelly O.; Herring, Nancy

    1994-11-01

    Production of chlorofluorocarbons (CFC's) and hydrochlorofluorocarbons (HCFC's) has been scheduled for phaseout because of the contribution of these chemicals to the depletion of the stratospheric ozone layer. CFC production is scheduled for phaseout by January 1, 1996; HCFC production will halt by the year 2020. The next generation of refrigerants is expected to be tested and widely available by the turn of the century. As a large-scale end user of CFC-based refrigerants, the U.S. Army is faced with a significant challenge by the phaseout of these chemicals. This report makes recommendations for refrigerant use in U.S. Army facility air-conditioning and refrigeration applications for the interim period from the present to the year 2000. Only equipment using CFC refrigerants is addressed since the lifetime of equipment using CFC's will expire before HCFC refrigerants are phased out. Available options to run as-is, convert, or replace CFC-based machines should be examined in cooperation with reputable contractors representing the original equipment manufacturers (OEM's). Only refrigerants approved by the U.S. Environmental Protection Agency (USEPA) should be considered for use in retrofitted or replaced equipment. As a part of the equipment evaluation, opportunities to improve system efficiency and reliability should also be sought.

  1. An experimental station for advanced research on condensed matter under extreme conditions at the European Synchrotron Radiation Facility - BM29 beamline

    Science.gov (United States)

    Filipponi, Adriano; Borowski, Michael; Bowron, Daniel T.; Ansell, Stuart; Di Cicco, Andrea; De Panfilis, Simone; Itiè, Jean-Paul

    2000-06-01

    We describe state-of-the-art experimental techniques using the beamline BM29 of the European Synchrotron Radiation Facility (ESRF). This station exploits the unique characteristics of an ESRF bending magnet source to provide a tunable, collimated, x-ray beam to perform high quality x-ray absorption spectroscopy within the energy range of E=5-75 keV using Si(111), Si(311), and Si(511) crystal pairs. Energy scans can be performed over this wide energy range with excellent reproducibility, stability and resolution, usually better than ΔE/E≃5×10-5. The experimental setup has been exploited to study condensed matter under extreme conditions. We describe here two sample environment devices; the L' Aquila-Camerino oven for high-temperature studies up to 3000 K in high vacuum and the Paris-Edinburgh press suitable for high-pressure high-temperature studies in the range 0.1-7 GPa and temperatures up to 1500 K. These devices can be integrated in an experimental setup which combines various control and detection systems suitable to perform x-ray absorption spectroscopy, x-ray absorption temperature scans, and energy scanning x-ray diffraction (ESXD). The ESXD setup is based on a scintillator detector behind a fixed angle collimator aligned to the sample. The combination of these three measurements, which can be performed in rapid sequence on the sample during the experiment, provides an essential tool for structural investigations and in situ sample characterization.

  2. Facilities & Leadership

    Data.gov (United States)

    Department of Veterans Affairs — The facilities web service provides VA facility information. The VA facilities locator is a feature that is available across the enterprise, on any webpage, for the...

  3. Biochemistry Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Biochemistry Facility provides expert services and consultation in biochemical enzyme assays and protein purification. The facility currently features 1) Liquid...

  4. On the physical conditions for arising a controlled fusion chain reaction supported by neutrons in fusion facilities with magnetic plasma confinement

    Directory of Open Access Journals (Sweden)

    A.N. Shmelyov

    2015-11-01

    The fusion neutron source is considered to be the “richest”: neutron generation is accompanied by relatively small-scale processes. The thermonuclear facility with low neutron absorption blanket under consideration here could create a high density neutron flux in the blanket. It can be concluded from the above that such thermonuclear facilities could be used for fast transmutation of long-lived fission products with low neutron absorption cross-section, and perhaps even without their preliminary isotopic separation.

  5. TNO HVAC facilities

    NARCIS (Netherlands)

    Hammink, H.A.J.

    2015-01-01

    TNO has extensive knowledge of heating, ventilation and air conditioning (HVAC), and can offer its services through theoretical studies, laboratory experiments and field measurements. This complete scope, made possible through our test facilities, enables the effective development of new products,

  6. Frost Effects Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Full-scale study in controlled conditionsThe Frost Effects Research Facility (FERF) is the largest refrigerated warehouse in the United States that can be used for a...

  7. Effects of wastewater effluent discharge and treatment facility upgrades on environmental and biological conditions of the upper Blue River, Johnson County, Kansas and Jackson County, Missouri, January 2003 through March 2009

    Science.gov (United States)

    Graham, Jennifer L.; Stone, Mandy L.; Rasmussen, Teresa J.; Poulton, Barry C.

    2010-01-01

    The Johnson County Blue River Main Wastewater Treatment Facility discharges into the upper Blue River near the border between Johnson County, Kansas and Jackson County, Missouri. During 2005 through 2007 the wastewater treatment facility underwent upgrades to increase capacity and include biological nutrient removal. The effects of wastewater effluent on environmental and biological conditions of the upper Blue River were assessed by comparing an upstream site to two sites located downstream from the wastewater treatment facility. Environmental conditions were evaluated using previously and newly collected discrete and continuous data, and were compared with an assessment of biological community composition and ecosystem function along the upstream-downstream gradient. This evaluation is useful for understanding the potential effects of wastewater effluent on water quality, biological community structure, and ecosystem function. In addition, this information can be used to help achieve National Pollution Discharge Elimination System (NPDES) wastewater effluent permit requirements after additional studies are conducted. The effects of wastewater effluent on the water-quality conditions of the upper Blue River were most evident during below-normal and normal streamflows (about 75 percent of the time), when wastewater effluent contributed more than 20 percent to total streamflow. The largest difference in water-quality conditions between the upstream and downstream sites was in nutrient concentrations. Total and inorganic nutrient concentrations at the downstream sites during below-normal and normal streamflows were 4 to 15 times larger than at the upstream site, even after upgrades to the wastewater treatment facility were completed. However, total nitrogen concentrations decreased in wastewater effluent and at the downstream site following wastewater treatment facility upgrades. Similar decreases in total phosphorus were not observed, likely because the biological

  8. Projected Salt Waste Production from a Commercial Pyroprocessing Facility

    Directory of Open Access Journals (Sweden)

    Michael F. Simpson

    2013-01-01

    Full Text Available Pyroprocessing of used nuclear fuel inevitably produces salt waste from electrorefining and/or oxide reduction unit operations. Various process design characteristics can affect the actual mass of such waste produced. This paper examines both oxide and metal fuel treatment, estimates the amount of salt waste generated, and assesses potential benefit of process options to mitigate the generation of salt waste. For reference purposes, a facility is considered in which 100 MT/year of fuel is processed. Salt waste estimates range from 8 to 20 MT/year from considering numerous scenarios. It appears that some benefit may be derived from advanced processes for separating fission products from molten salt waste, but the degree of improvement is limited. Waste form production is also considered but appears to be economically unfavorable. Direct disposal of salt into a salt basin type repository is found to be the most promising with respect to minimizing the impact of waste generation on the economic feasibility and sustainability of pyroprocessing.

  9. Waste Facilities

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset was developed from the Vermont DEC's list of certified solid waste facilities. It includes facility name, contact information, and the materials...

  10. Fabrication Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Fabrication Facilities are a direct result of years of testing support. Through years of experience, the three fabrication facilities (Fort Hood, Fort Lewis, and...

  11. Validation of the RELAP5 code for the modeling of flashing-induced instabilities under natural-circulation conditions using experimental data from the CIRCUS test facility

    Energy Technology Data Exchange (ETDEWEB)

    Kozmenkov, Y. [Helmholtz-Zentrum Dresden-Rossendorf e.V. (FZD), Institute of Safety Research, P.O.B. 510119, D-01324 Dresden (Germany); Institute of Physics and Power Engineering, Obninsk (Russian Federation); Rohde, U., E-mail: U.Rohde@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf e.V. (FZD), Institute of Safety Research, P.O.B. 510119, D-01324 Dresden (Germany); Manera, A. [Paul Scherrer Institute (Switzerland)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer We report about the simulation of flashing-induced instabilities in natural circulation systems. Black-Right-Pointing-Pointer Flashing-induced instabilities are of relevance for operation of pool-type reactors of small power at low pressure. Black-Right-Pointing-Pointer The RELAP5 code is validated against measurement data from natural circulation experiments. Black-Right-Pointing-Pointer The magnitude and frequency of the oscillations were reproduced in good agreement with the measurement data. - Abstract: This paper reports on the use of the RELAP5 code for the simulation of flashing-induced instabilities in natural circulation systems. The RELAP 5 code is intended to be used for the simulation of transient processes in the Russian RUTA reactor concept operating at atmospheric pressure with forced convection of coolant. However, during transient processes, natural circulation with flashing-induced instabilities might occur. The RELAP5 code is validated against measurement data from natural circulation experiments performed within the framework of a European project (NACUSP) on the CIRCUS facility. The facility, built at the Delft University of Technology in The Netherlands, is a water/steam 1:1 height-scaled loop of a typical natural-circulation-cooled BWR. It was shown that the RELAP5 code is able to model all relevant phenomena related to flashing induced instabilities. The magnitude and frequency of the oscillations were reproduced in a good agreement with the measurement data. The close correspondence to the experiments was reached by detailed modeling of all components of the CIRCUS facility including the heat exchanger, the buffer vessel and the steam dome at the top of the facility.

  12. Geohydrologic conditions at the nuclear-fuels reprocessing plant and waste-management facilities at the Western New York Nuclear Service Center, Cattaraugus County, New York

    Science.gov (United States)

    Bergeron, M.P.; Kappel, W.M.; Yager, R.M.

    1987-01-01

    A nuclear-fuel reprocessing plant, a high-level radioactive liquid-waste tank complex, and related waste facilities occupy 100 hectares (ha) within the Western New York Nuclear Service Center near West Valley, N.Y. The facilities are underlain by glacial and postglacial deposits that fill an ancestrial bedrock valley. The main plant facilities are on an elevated plateau referred to as the north plateau. Groundwater on the north plateau moves laterally within a surficial sand and gravel from the main plant building to areas northeast, east, and southeast of the facilities. The sand and gravel ranges from 1 to 10 m thick and has a hydraulic conductivity ranging from 0.1 to 7.9 m/day. Two separate burial grounds, a 4-ha area for low-level radioactive waste disposal and a 2.9-ha area for disposal of higher-level waste are excavated into a clay-rich till that ranges from 22 to 28 m thick. Migration of an organic solvent from the area of higher level waste at shallow depth in the till suggests that a shallow, fractured, oxidized, and weathered till is a significant pathway for lateral movement of groundwater. Below this zone, groundwater moves vertically downward through the till to recharge a lacustrine silt and fine sand. Within the saturated parts of the lacustrine unit, groundwater moves laterally to the northeast toward Buttermilk Creek. Hydraulic conductivity of the till, based on field and laboratory analyses , ranges from 0.000018 to 0.000086 m/day. (USGS)

  13. Conceptual design report: Nuclear materials storage facility renovation. Part 5, Structural/seismic investigation. Section A report, existing conditions calculations/supporting information

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-14

    The Nuclear Materials Storage Facility (NMSF) at the Los Alamos National Laboratory (LANL) was a Fiscal Year (FY) 1984 line-item project completed in 1987 that has never been operated because of major design and construction deficiencies. This renovation project, which will correct those deficiencies and allow operation of the facility, is proposed as an FY 97 line item. The mission of the project is to provide centralized intermediate and long-term storage of special nuclear materials (SNM) associated with defined LANL programmatic missions and to establish a centralized SNM shipping and receiving location for Technical Area (TA)-55 at LANL. Based on current projections, existing storage space for SNM at other locations at LANL will be loaded to capacity by approximately 2002. This will adversely affect LANUs ability to meet its mission requirements in the future. The affected missions include LANL`s weapons research, development, and testing (WRD&T) program; special materials recovery; stockpile survelliance/evaluation; advanced fuels and heat sources development and production; and safe, secure storage of existing nuclear materials inventories. The problem is further exacerbated by LANL`s inability to ship any materials offsite because of the lack of receiver sites for mate rial and regulatory issues. Correction of the current deficiencies and enhancement of the facility will provide centralized storage close to a nuclear materials processing facility. The project will enable long-term, cost-effective storage in a secure environment with reduced radiation exposure to workers, and eliminate potential exposures to the public. Based upon US Department of Energy (DOE) Albuquerque Operations (DOE/Al) Office and LANL projections, storage space limitations/restrictions will begin to affect LANL`s ability to meet its missions between 1998 and 2002.

  14. A facile sol-gel strategy for the scalable synthesis of CuFe2O4 nanoparticles with enhanced infrared radiation property: Influence of the synthesis conditions

    Science.gov (United States)

    Hou, Haili; Xu, Guoyue; Tan, Shujuan; Zhu, Yongmei

    2017-09-01

    CuFe2O4 particles were successfully engineered by a facile sol-gel method. The synthesized products were characterized physically by X-ray diffraction (XRD), scanning electron microscopy (SEM). Besides, the effects of the sintering temperature and the molar ration of citric acid/the total metal cations (CA/MC) on their infrared radiant properties were investigated at the wavelength of 3-5 μm. The highest infrared emission value ca. 0.911 was obtained when the test temperature was conducted at 800 °C, indicating its potential application in infrared heating, infrared coating and drying fields.

  15. Do umbilical outpouchings affect the behaviour or clinical condition of pigs during 6 h housing in a pre-transport pick-up facility?

    Science.gov (United States)

    Schild, Sarah-Lina Aa; Rousing, Tine; Jensen, Henrik E; Barington, Kristiane; Herskin, Mette S

    2015-08-01

    This study focused on behavioural and clinical effects of umbilical outpouchings (UOs) in pigs. Matched pairs of pigs with UOs (diameter 12 cm; range 4-20; diagnosed p.m. as hernia or non-hernia) and controls (N=28) were compared during a 6-h stay in a pick-up facility. Overall, skin lesion scores were increased after the 6-h stay. Behaviour of the UO-pigs differed from the controls (a shorter latency to lie down (Pumbilical hernia showed e.g. increased sitting (Phernia UOs. No effects of the size of the OUs were found. These results are among the first to establish knowledge about UO-pigs and suggest that a stay in a pick-up facility can be challenging for pig welfare. The behavioural findings suggest that UO-pigs, and especially pigs with hernia, may be less fit for mixing and housing in barren environments. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Ultrasound promoted facile one pot synthesis of triazole derivatives catalyzed by functionalized graphene oxide Cu(I) complex under mild conditions.

    Science.gov (United States)

    Naeimi, Hossein; Shaabani, Rahele

    2017-01-01

    A facile one pot three component reaction of alkyl halides, sodium azide with terminal alkynes can be catalyzed by functionalized graphene oxide copper (I) complex under ultrasonic irradiation at room temperature. In this protocol, the 1,4-disubstituted 1,2,3-triazoles were afforded as target pure products in excellent yields and short reaction times. The prepared catalyst has been characterized by Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction spectroscopy (XRD), Energy Dispersive X-ray (EDX) and field emission scanning electron microscopy (FE-SEM) techniques. Also, the catalyst is chemoselective and stable and can be reused several times without any appreciable loss of its catalytic activity. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Novel test-bed facility for PSI issues in fusion reactor conditions on the base of next generation QSPA plasma accelerator

    Science.gov (United States)

    Garkusha, I. E.; Chebotarev, V. V.; Herashchenko, S. S.; Makhlaj, V. A.; Kulik, N. V.; Ladygina, M. S.; Marchenko, A. K.; Petrov, Yu. V.; Staltsov, V. V.; Shevchuk, P. V.; Solyakov, D. G.; Yelisyeyev, D. V.

    2017-11-01

    In this report a concept of a new generation QSPA with external B-field up to 2 T has been discussed. A novel test-bed facility, which was recently constructed in Kharkov IPP NSC KIPT, has been described. It allows for a new level of plasma stream parameters and its wide variation in new QSPA-M device, as well as possible combination of steady-state and pulsed plasma loads to the materials during the exposures. First plasma is recently obtained. Careful optimization of the operational regimes of the plasma accelerator’s functional components and plasma dynamics in the magnetic system of QSPA-M device has started approaching step by step the necessary level of plasma parameters and their effective variation. The relevant results on plasma stream characterization are presented. Energy density distributions in plasma stream have been measured with calorimetry. Spectroscopy and probe technique have also been applied for plasma parameters measurements. The obtained results demonstrate the ability of QSPA-M to reproduce the ELM impacts in fusion reactor, both in terms of heat load and particle flux to the surface.

  18. The Maintenance of Heating, Ventilating and Air-Conditioning Systems and Indoor Air Quality in Schools: A Guide for School Facility Managers. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.

    To help maintain good indoor air quality (IAQ) in schools, guidance for the development and implementation of an effective program for maintenance and operation of heating, ventilating, and air-conditioning (HVAC) systems are discussed. Frequently, a building's occupants will complain about IAQ when the temperature or humidity are at uncomfortable…

  19. Mammography Facilities

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Mammography Facility Database is updated periodically based on information received from the four FDA-approved accreditation bodies: the American College of...

  20. Canyon Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — B Plant, T Plant, U Plant, PUREX, and REDOX (see their links) are the five facilities at Hanford where the original objective was plutonium removal from the uranium...

  1. Health Facilities

    Science.gov (United States)

    Health facilities are places that provide health care. They include hospitals, clinics, outpatient care centers, and specialized care centers, such as birthing centers and psychiatric care centers. When you ...

  2. Synthesis of Sensor Fish Data for Assessment of Fish Passage Conditions at Turbines, Spillways, and Bypass Facilities – Phase 1: The Dalles Dam Spillway Case Study

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Zhiqun; Serkowski, John A.; Fu, Tao; Carlson, Thomas J.; Richmond, Marshall C.

    2007-12-31

    This report summarizes the characterization of spillway passage conditions at The Dalles Dam in 2006 and the effort to complete a comprehensive database for data sets from The Dalles Dam spillway Sensor Fish and balloon-tagged live fish experiments. Through The Dalles Dam spillway case study, Pacific Northwest National Laboratory (PNNL) researchers evaluated the database as an efficient means for accessing and retrieving system-wide data for the U.S Army Corps of Engineers (USACE).

  3. Facile synthesis of 1-naphthol azo dyes with nano SiO2/HIO4 under solvent-free conditions

    OpenAIRE

    A.R. Pourali; A. Bamoniri; S.M.R. Nazifi

    2013-01-01

    Nano-silica supported periodic acid (nano-SPIA) has been utilized as a heterogeneous reagent for a highly efficient and one pot synthesis of azo dyes based on 1-naphthol under solvent-free conditions at room temperature. This method has some advantages, the reaction workup is very easy and the catalyst can be easily separated from the reaction mixture and one-pot procedure. The related products have been obtained in good to excellent yields, high purity and short reaction times. The structure...

  4. Mound facility physical characterization

    Energy Technology Data Exchange (ETDEWEB)

    Tonne, W.R.; Alexander, B.M.; Cage, M.R.; Hase, E.H.; Schmidt, M.J.; Schneider, J.E.; Slusher, W.; Todd, J.E.

    1993-12-01

    The purpose of this report is to provide a baseline physical characterization of Mound`s facilities as of September 1993. The baseline characterizations are to be used in the development of long-term future use strategy development for the Mound site. This document describes the current missions and alternative future use scenarios for each building. Current mission descriptions cover facility capabilities, physical resources required to support operations, current safety envelope and current status of facilities. Future use scenarios identify potential alternative future uses, facility modifications required for likely use, facility modifications of other uses, changes to safety envelope for the likely use, cleanup criteria for each future use scenario, and disposition of surplus equipment. This Introductory Chapter includes an Executive Summary that contains narrative on the Functional Unit Material Condition, Current Facility Status, Listing of Buildings, Space Plans, Summary of Maintenance Program and Repair Backlog, Environmental Restoration, and Decontamination and Decommissioning Programs. Under Section B, Site Description, is a brief listing of the Site PS Development, as well as Current Utility Sources. Section C contains Site Assumptions. A Maintenance Program Overview, as well as Current Deficiencies, is contained within the Maintenance Program Chapter.

  5. Facile and rapid synthesis of divers xanthene derivatives using lanthanum(III chloride/chloroacetic acid as an efficient and reusable catalytic system under solvent-free conditions

    Directory of Open Access Journals (Sweden)

    Pouramiri Behjat

    2017-01-01

    Full Text Available LaCl3/ClCH2COOH was used as an efficient, and recyclable catalytic system for synthesis of 11H-benzo[a]xanthene-11-one, hexahydro-1H-xanthene- 1,8(2H-dione and 11-aryl-10H-diindeno[1,2-b:2′,1′-e]pyran-10,12(11H-dione derivatives via a one-pot three-component reaction of aldehydes, 2-naphthol, and cyclic 1,3-dicarbonyl compounds. The reactions proceeded rapidly at 70°C under solvent-free conditions and the desired products were obtained in good to excellent yields.

  6. Aqueous hydrodechlorination of 4-chlorophenol over an Rh/reduced graphene oxide synthesized by a facile one-pot solvothermal process under mild conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Yanlin [Chemical Synthesis and Pollution Control, Key Laboratory of Sichuan Province, College of Chemistry and Chemical Industry, China West Normal University, Nanchong 637002 (China); Fan, Guangyin, E-mail: fanguangyin@cwnu.edu.cn [Chemical Synthesis and Pollution Control, Key Laboratory of Sichuan Province, College of Chemistry and Chemical Industry, China West Normal University, Nanchong 637002 (China); Wang, Chenyu [Department of Chemistry, State University of New York at Binghamton, Binghamton, NY 13902 (United States)

    2014-06-01

    Graphical abstract: The Rh nanoparticles/reduced graphene oxide (Rh NPs/RGO) nanocatalyst synthesized by a solvothermal technique showed high activity and stability for the hydrodechlorination of 4-chlorophenol under mild conditions. - Highlights: • Rh/RGO was synthesized through a one-pot polyol reduction of GO and RhCl{sub 3}. • Complete HDC of 4-chlorophenol was obtained in aqueous phase without any additive. • The Rh/RGO exhibited an excellent catalytic performance for HDC reaction. - Abstract: Reduced graphene oxide (RGO) supported rhodium nanoparticles (Rh-NPs/RGO) was synthesized through one-pot polyol co-reduction of graphene oxide (GO) and rhodium chloride. The catalytic property of Rh-NPs/RGO was investigated for the aqueous phase hydrodechlorination (HDC) of 4-chlorophenol (4-CP). A complete conversion of 4-CP into high valued products of cyclohexanone (selectivity: 23.2%) and cyclohexanol (selectivity: 76.8%) was successfully achieved at 303 K and balloon hydrogen pressure in a short reaction time of 50 min when 1.5 g/L of 4-CP was introduced. By comparing with Rh-NPs deposited on the other supports, Rh-NPs/RGO delivered the highest initial rate (111.4 mmol/g{sub Rh} min) for 4-CP HDC reaction under the identical conditions. The substantial catalytic activity of Rh-NPs/RGO can be ascribed to the small and uniform particle size of Rh (average particle size was 1.7 ± 0.14 nm) on the surface of the RGO sheets and an electron-deficient state of Rh in the catalyst as a result of the strong interaction between the active sites and the surface function groups of RGO.

  7. A facile method to establish human induced pluripotent stem cells from adult blood cells under feeder-free and xeno-free culture conditions: a clinically compliant approach.

    Science.gov (United States)

    Chou, Bin-Kuan; Gu, Haihui; Gao, Yongxing; Dowey, Sarah N; Wang, Ying; Shi, Jun; Li, Yanxin; Ye, Zhaohui; Cheng, Tao; Cheng, Linzhao

    2015-04-01

    Reprogramming human adult blood mononuclear cells (MNCs) cells by transient plasmid expression is becoming increasingly popular as an attractive method for generating induced pluripotent stem (iPS) cells without the genomic alteration caused by genome-inserting vectors. However, its efficiency is relatively low with adult MNCs compared with cord blood MNCs and other fetal cells and is highly variable among different adult individuals. We report highly efficient iPS cell derivation under clinically compliant conditions via three major improvements. First, we revised a combination of three EBNA1/OriP episomal vectors expressing five transgenes, which increased reprogramming efficiency by ≥10-50-fold from our previous vectors. Second, human recombinant vitronectin proteins were used as cell culture substrates, alleviating the need for feeder cells or animal-sourced proteins. Finally, we eliminated the previously critical step of manually picking individual iPS cell clones by pooling newly emerged iPS cell colonies. Pooled cultures were then purified based on the presence of the TRA-1-60 pluripotency surface antigen, resulting in the ability to rapidly expand iPS cells for subsequent applications. These new improvements permit a consistent and reliable method to generate human iPS cells with minimal clonal variations from blood MNCs, including previously difficult samples such as those from patients with paroxysmal nocturnal hemoglobinuria. In addition, this method of efficiently generating iPS cells under feeder-free and xeno-free conditions allows for the establishment of clinically compliant iPS cell lines for future therapeutic applications. ©AlphaMed Press.

  8. Risk Analysis of Flare Flame-out Condition in a Gas Process Facility Analyse des risques des conditions d’extinction de torche au sein d’une installation de traitement de gaz

    Directory of Open Access Journals (Sweden)

    Zadakbar O.

    2011-02-01

    Full Text Available Flaring is a common method of disposal of flammable waste gases in the downstream industries. Flare flame out (flame lift-off or blow-outs often occurs causing toxic vapors to discharge. The toxic gases released may have hazardous effects on the surrounding environment. To study the effect of inhalation exposure of these toxic gases on human health, the four steps of the EPA (Environmental Protection Agency framework with the field data to quantify the cancer and non-cancer health risks are integrated in this paper. As a part of exposure assessment, gas dispersion modeling using AERMOD and UDM-PHAST is applied in two different conditions of normal flaring and flare flame out during a particular climate condition in Khangiran region. Recommendations to avoid flare flame out conditions are also presented here. Le torchage est un procédé courant d’élimination des gaz résiduaires inflammables dans les industries de traitement. L’extinction de la torche (par décollage ou soufflage de flamme provoque souvent une émission de vapeurs toxiques. Ces gaz toxiques libérés peuvent présenter des effets dangereux sur le milieu environnant. Pour étudier l’effet d’une exposition par inhalation de ces gaz toxiques sur la santé, cet article croise les quatre étapes de la démarche de l’EPA (Environmental Protection Agency, Agence de protection de l’environnement avec les données d’exploitation afin de quantifier le risque sanitaire cancérologique et non cancérologique. Dans le cadre de l’estimation d’exposition, une modélisation de dispersion des gaz utilisant AERMOD et UDM-PHAST est évaluée dans deux configurations différentes de torchage normal et d’extinction de torche à l’occasion de conditions climatiques particulières dans la région du Khangiran. L’article propose également des recommandations destinées à éviter les conditions d’une extinction de flamme de torche.

  9. The Impact of Biofilms upon Surfaces Relevant to an Intermediate Level Radioactive Waste Geological Disposal Facility under Simulated Near-Field Conditions

    Directory of Open Access Journals (Sweden)

    Christopher J. Charles

    2017-07-01

    Full Text Available The ability of biofilms to form on a range of materials (cementious backfill (Nirex Reference Vault Backfill (NRVB, graphite, and stainless steel relevant to potential UK intermediate level radioactive waste (ILW disposal concepts was investigated by exposing these surfaces to alkaliphilic flocs generated by mature biofilm communities. Flocs are aggregates of biofilm material that are able to act as a transport vector for the propagation of biofilms. In systems where biofilm formation was observed there was also a decrease in the sorption of isosaccharinic acids to the NRVB. The biofilms were composed of cells, extracellular DNA (eDNA, proteins, and lipids with a smaller polysaccharide fraction, which was biased towards mannopyranosyl linked carbohydrates. The same trend was seen with the graphite and stainless steel surfaces at these pH values, but in this case the biofilms associated with the stainless steel surfaces had a distinct eDNA basal layer that anchored the biofilm to the surface. At pH 13, no structured biofilm was observed, rather all the surfaces accumulated an indistinct organic layer composed of biofilm materials. This was particularly the case for the stainless steel coupons which accumulated relatively large quantities of eDNA. The results demonstrate that there is the potential for biofilm formation in an ILW-GDF provided an initiation source for the microbial biofilm is present. They also suggest that even when conditions are too harsh for biofilm formation, exposed surfaces may accumulate organic material such as eDNA.

  10. Planning Facilities.

    Science.gov (United States)

    Flynn, Richard B., Ed.; And Others

    1983-01-01

    Nine articles give information to help make professionals in health, physical education, recreation, dance, and athletics more knowledgeable about planning facilities. Design of natatoriums, physical fitness laboratories, fitness trails, gymnasium lighting, homemade play equipment, indoor soccer arenas, and dance floors is considered. A…

  11. [Daily living activities and oral condition among care facility residents with severe intellectual disabilities. Comparative analyses between residents receiving tooth-brushing assistance and those not receiving tooth-brushing assistance].

    Science.gov (United States)

    Chiwata, Kaoru; Takeda, Fumi

    2007-06-01

    To clarify 1) differences in daily living activities and oral condition among care facility residents with severe intellectual disabilities and 2) chronological changes in daily living activities and oral condition for residents receiving tooth-brushing assistance and those never receiving tooth-brushing assistance. Subjects were 44 residents at a care facility for individuals with severe intellectual disabilities, who underwent dental screening in July 1994 and October 2003. At each time point, daily living activities, behavior during oral health guidance, behavior during dental health screening and oral condition were compared between residents receiving tooth-brushing assistance (assistance group) and those not receiving tooth-brushing assistance (independent group). Furthermore, chronological changes were analyzed for residents requiring assistance at both screenings, those requiring assistance only at the second screening, and those not requiring assistance at either screening. 1) In the assistance group, 100% and 36.4% of residents were unable to brush their teeth independently in 1994 and 2003, respectively. Significant differences between the assistance and independent groups were observed in all items of behavior during dental health screening in 1994, but not in 2003. No significant intergroup differences in oral condition were observed in 1994, but differences were seen in 2003; when compared to the assistance group, the number of lost teeth was significantly higher in the independent group, while the number of remaining teeth was lower. 2) Regarding changes over the nine-year period, a significantly greater proportion of residents not requiring assistance at either screening and those requiring assistance only at the second screening finally required assistance in bathing. As for oral condition, no significant changes in healthy teeth were observed in residents requiring assistance at both screening time points, while significant increases in dental

  12. Behavior of a VVER fuel element tested under severe accident conditions in the CORA facility. Test results of experiment CORA-W1

    Energy Technology Data Exchange (ETDEWEB)

    Hagen, S.; Hofmann, P.; Noack, V.; Schanz, G.; Schumacher, G.; Sepold, L.

    1994-01-01

    Test bundle CORA-W1 was without absorber material. As in the earlier CORA tests the test bundles were subjected to temperature transients of a slow heatup rate in a steam environment. The transient phases of the test were initiated with a temperature ramp rate of 1 K/s. With these conditions a so-called small-break LOCA was simulated. The temperature escalation due to the exothermal zirconium/niobium-steam reaction started at about 1200 C, leading the bundle to a maximum temperature of approximately 1900 C. With the movement of the melt also heat is transported to the lower region. Below 300 mm elevation the test bundle remained intact due to the axial temeprature distribution. W2 ist characterized by a strong oxidation above 300 mm elevation. Besides the severe oxidation the test bundle resulted in considerable fuel dissolution by ZrNb1/UO{sub 2} interaction in the upper part, complete spacer destruction at 600 mm due to chemical interactions between steel and the ZSrNb1 cladding. Despite some specific features the material behavior of the VVER-1000 bundle is comparable to that observed in the PWR and BWR test using fuel elements typical for Western countries. (orig./HP) [Deutsch] Versuchsbuendel CORA-W1 hatte kein Absorberelement. Wie in den CORA-Versuchen zuvor wurden die Testbuendel in Dampfatmosphaere Temperaturtransienten mit langsamer Aufheizrate ausgesetzt. Damit wurde ein Unfallablauf fuer einen LWR simuliert, der sich aus einem Kuehlmittelverluststoerfall durch Auftreten eines sogenannten kleinen Lecks entwickeln kann. Die Temperatureskalation - aufgrund der exothermen Zirkon/Niob-Wasserdampfreaktion - setzte ab ca. 1100 C ein. Die Hoechsttemperaturen im Buendel betrugen 2000 C. Die Versuchsdaten des Experiments CORA-W1 werden zusammen mit ersten Ergebnissen der Nachuntersuchung dargelegt. Das Versuchsbuendel weist eine starke Oxidation im oberen Bereich auf. Der untere Buendelabschnitt (bis 400 mm) blieb aufgrund der niedrigen Temperaturen in diesem

  13. Hanford Facility RCRA permit handbook

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    Purpose of this Hanford Facility (HF) RCRA Permit Handbook is to provide, in one document, information to be used for clarification of permit conditions and guidance for implementing the HF RCRA Permit.

  14. Modernizing sports facilities

    Energy Technology Data Exchange (ETDEWEB)

    Dustin, R. [McKenney`s, Inc., Atlanta, GA (United States)

    1996-09-01

    Modernization and renovation of sports facilities challenge the design team to balance a number of requirements: spectator and owner expectations, existing building and site conditions, architectural layouts, code and legislation issues, time constraints and budget issues. System alternatives are evaluated and selected based on the relative priorities of these requirements. These priorities are unique to each project. At Alexander Memorial Coliseum, project schedules, construction funds and facility usage became the priorities. The ACC basketball schedule and arrival of the Centennial Olympics dictated the construction schedule. Initiation and success of the project depended on the commitment of the design team to meet coliseum funding levels established three years ago. Analysis of facility usage and system alternative capabilities drove the design team to select a system that met the project requirements and will maximize the benefits to the owner and spectators for many years to come.

  15. Emission Facilities - Erosion & Sediment Control Facilities

    Data.gov (United States)

    NSGIC Education | GIS Inventory — An Erosion and Sediment Control Facility is a DEP primary facility type related to the Water Pollution Control program. The following sub-facility types related to...

  16. Air Quality Facilities

    Data.gov (United States)

    Iowa State University GIS Support and Research FacilityFacilities with operating permits for Title V of the Federal Clean Air Act, as well as facilities required to submit an air emissions inventory, and other facilities...

  17. Facility Modernization Report

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, D; Ackley, R

    2007-05-10

    Modern and technologically up-to-date facilities and systems infrastructure are necessary to accommodate today's research environment. In response, Lawrence Livermore National Laboratory (LLNL) has a continuing commitment to develop and apply effective management models and processes to maintain, modernize, and upgrade its facilities to meet the science and technology mission. The Facility Modernization Pilot Study identifies major subsystems of facilities that are either technically or functionally obsolete, lack adequate capacity and/or capability, or need to be modernized or upgraded to sustain current operations and program mission. This study highlights areas that need improvement, system interdependencies, and how these systems/subsystems operate and function as a total productive unit. Although buildings are 'grandfathered' in and are not required to meet current codes unless there are major upgrades, this study also evaluates compliance with 'current' building, electrical, and other codes. This study also provides an evaluation of the condition and overall general appearance of the structure.

  18. Hanford surplus facilities programs facilities listings and descriptions. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Kiser, S.K.; Witt, T.L.

    1994-01-01

    On the Hanford Site, many surplus facilities exist (including buildings, stacks, tanks, cribs, burial grounds, and septic systems) that are scheduled to be decommissioned. Many of these facilities contain large inventories of radionuclides, which present potential radiological hazards on and off the Hanford Site. Some structures with limited structural deterioration present potential radiological and industrial safety hazards to personnel. Because of the condition of these facilities, a systematic surveillance and maintenance program is performed to identify and correct potential hazards to personnel and the environment until eventual decommissioning operations are completed.

  19. Breadboard Facility

    Science.gov (United States)

    1977-01-01

    In the sixties, Chrysler was NASA's prime contractor for the Saturn I and IB test launch vehicles. The company installed and operated at Huntsville what was known as the Saturn I/IB Development Breadboard Facility. "Breadboard," means an array of electrical and electronic equipment for performing a variety of development and test functions. This work gave Chrysler a broad capability in computerized testing to assure quality control in development of solid-state electronic systems. Today that division is manufacturing many products not destined for NASA, most of them being associated with the company's automotive line. A major project is production and quality-control testing of the "lean-burn" engine, one that has a built-in Computer to control emission timing, and allow the engine to run on a leaner mixture of fuel and air. Other environment-related products include vehicle emission analyzers. The newest of the line is an accurate, portable solid state instrument for testing auto exhaust gases. The exhaust analyzers, now being produced for company dealers and for service

  20. Irradiation Facilities at CERN

    CERN Document Server

    Gkotse, Blerina; Carbonez, Pierre; Danzeca, Salvatore; Fabich, Adrian; Garcia, Alia, Ruben; Glaser, Maurice; Gorine, Georgi; Jaekel, Martin, Richard; Mateu,Suau, Isidre; Pezzullo, Giuseppe; Pozzi, Fabio; Ravotti, Federico; Silari, Marco; Tali, Maris

    2017-01-01

    CERN provides unique irradiation facilities for applications in many scientific fields. This paper summarizes the facilities currently operating for proton, gamma, mixed-field and electron irradiations, including their main usage, characteristics and information about their operation. The new CERN irradiation facilities database is also presented. This includes not only CERN facilities but also irradiation facilities available worldwide.

  1. North Slope, Alaska ESI: FACILITY (Facility Points)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for oil field facilities for the North Slope of Alaska. Vector points in this data set represent oil field facility locations. This data...

  2. Jupiter Laser Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Jupiter Laser Facility is an institutional user facility in the Physical and Life Sciences Directorate at LLNL. The facility is designed to provide a high degree...

  3. Basic Research Firing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Basic Research Firing Facility is an indoor ballistic test facility that has recently transitioned from a customer-based facility to a dedicated basic research...

  4. Aperture area measurement facility

    Data.gov (United States)

    Federal Laboratory Consortium — NIST has established an absolute aperture area measurement facility for circular and near-circular apertures use in radiometric instruments. The facility consists of...

  5. Facility Registry Service (FRS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Facility Registry Service (FRS) provides an integrated source of comprehensive (air, water, and waste) environmental information about facilities across EPA,...

  6. Licensed Healthcare Facilities

    Data.gov (United States)

    California Department of Resources — The Licensed Healthcare Facilities point layer represents the locations of all healthcare facilities licensed by the State of California, Department of Health...

  7. High Throughput Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Argonne?s high throughput facility provides highly automated and parallel approaches to material and materials chemistry development. The facility allows scientists...

  8. Characterization of the 309 fuel examination facility

    Energy Technology Data Exchange (ETDEWEB)

    Greenhalgh, W.O.; Cornwell, B.C.

    1997-07-09

    This document identifies radiological, chemical and physical conditions inside the Fuel Examination Facility. It is located inside the Plutonium Recycle Test Reactor containment structure (309 Building.) The facility was a hot cell used for examination of PRTR fuel and equipment during the 1960`s. Located inside the cell is a PRTR shim rod assembly, reported are radiological conditions of the sample. The conditions were assessed as part of overall 309 Building transition.

  9. Guide to research facilities

    Energy Technology Data Exchange (ETDEWEB)

    1993-06-01

    This Guide provides information on facilities at US Department of Energy (DOE) and other government laboratories that focus on research and development of energy efficiency and renewable energy technologies. These laboratories have opened these facilities to outside users within the scientific community to encourage cooperation between the laboratories and the private sector. The Guide features two types of facilities: designated user facilities and other research facilities. Designated user facilities are one-of-a-kind DOE facilities that are staffed by personnel with unparalleled expertise and that contain sophisticated equipment. Other research facilities are facilities at DOE and other government laboratories that provide sophisticated equipment, testing areas, or processes that may not be available at private facilities. Each facility listing includes the name and phone number of someone you can call for more information.

  10. Chemical facility preparedness a comprehensive approach

    OpenAIRE

    Pennington, Daniel

    2006-01-01

    CHDS State/Local Experts agree that the nation's chemical facilities are attractive targets for terrorists. This consensus is due to several conditions. First, there are thousands of facilities scattered across the country that use, manufacture or store large stockpiles of toxic and/or flammable substances. Many sites are clustered together in densely populated areas and are poorly protected. If terrorists cause catastrophic chemical releases or explosions at these key facilities, large nu...

  11. Subsurface Facility System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    Eric Loros

    2001-07-31

    The Subsurface Facility System encompasses the location, arrangement, size, and spacing of the underground openings. This subsurface system includes accesses, alcoves, and drifts. This system provides access to the underground, provides for the emplacement of waste packages, provides openings to allow safe and secure work conditions, and interfaces with the natural barrier. This system includes what is now the Exploratory Studies Facility. The Subsurface Facility System physical location and general arrangement help support the long-term waste isolation objectives of the repository. The Subsurface Facility System locates the repository openings away from main traces of major faults, away from exposure to erosion, above the probable maximum flood elevation, and above the water table. The general arrangement, size, and spacing of the emplacement drifts support disposal of the entire inventory of waste packages based on the emplacement strategy. The Subsurface Facility System provides access ramps to safely facilitate development and emplacement operations. The Subsurface Facility System supports the development and emplacement operations by providing subsurface space for such systems as ventilation, utilities, safety, monitoring, and transportation.

  12. Sports Facility Management.

    Science.gov (United States)

    Walker, Marcia L., Ed.; Stotlar, David K., Ed.

    The numbers of both sports facility management college courses and sport and exercise facilities are increasing, along with the need for an understanding of the trends and management concepts of these facilities. This book focuses exclusively on managing facilities where sporting events occur and includes examples in physical education, athletics,…

  13. Reliable Facility Location Problem with Facility Protection.

    Science.gov (United States)

    Tang, Luohao; Zhu, Cheng; Lin, Zaili; Shi, Jianmai; Zhang, Weiming

    2016-01-01

    This paper studies a reliable facility location problem with facility protection that aims to hedge against random facility disruptions by both strategically protecting some facilities and using backup facilities for the demands. An Integer Programming model is proposed for this problem, in which the failure probabilities of facilities are site-specific. A solution approach combining Lagrangian Relaxation and local search is proposed and is demonstrated to be both effective and efficient based on computational experiments on random numerical examples with 49, 88, 150 and 263 nodes in the network. A real case study for a 100-city network in Hunan province, China, is presented, based on which the properties of the model are discussed and some managerial insights are analyzed.

  14. Reliable Facility Location Problem with Facility Protection.

    Directory of Open Access Journals (Sweden)

    Luohao Tang

    Full Text Available This paper studies a reliable facility location problem with facility protection that aims to hedge against random facility disruptions by both strategically protecting some facilities and using backup facilities for the demands. An Integer Programming model is proposed for this problem, in which the failure probabilities of facilities are site-specific. A solution approach combining Lagrangian Relaxation and local search is proposed and is demonstrated to be both effective and efficient based on computational experiments on random numerical examples with 49, 88, 150 and 263 nodes in the network. A real case study for a 100-city network in Hunan province, China, is presented, based on which the properties of the model are discussed and some managerial insights are analyzed.

  15. Shapley Facility Location Games

    OpenAIRE

    Ben-Porat, Omer; Tennenholtz, Moshe

    2017-01-01

    Facility location games have been a topic of major interest in economics, operations research and computer science, starting from the seminal work by Hotelling. Spatial facility location models have successfully predicted the outcome of competition in a variety of scenarios. In a typical facility location game, users/customers/voters are mapped to a metric space representing their preferences, and each player picks a point (facility) in that space. In most facility location games considered i...

  16. REMEDIATION FACILITY WORKER DOSE ASSESSMENT

    Energy Technology Data Exchange (ETDEWEB)

    V. Arakali; E. Faillace

    2004-02-27

    The purpose of this design calculation is to estimate radiation doses received by personnel in the Remediation Facility performing operations to receive, prepare, open, repair, recover, disposition, and correct off-normal and non-standard conditions with casks, canisters, spent nuclear fuel (SNF) assemblies, and waste packages (WP). The specific scope of work contained in this calculation covers both collective doses and individual worker group doses on an annual basis, and includes the contributions due to external and internal radiation. The results of this calculation will be used to support the design of the Remediation Facility and provide occupational dose estimates for the License Application.

  17. DKIST facility management system integration

    Science.gov (United States)

    White, Charles R.; Phelps, LeEllen

    2016-07-01

    The Daniel K. Inouye Solar Telescope (DKIST) Observatory is under construction at Haleakalā, Maui, Hawai'i. When complete, the DKIST will be the largest solar telescope in the world. The Facility Management System (FMS) is a subsystem of the high-level Facility Control System (FCS) and directly controls the Facility Thermal System (FTS). The FMS receives operational mode information from the FCS while making process data available to the FCS and includes hardware and software to integrate and control all aspects of the FTS including the Carousel Cooling System, the Telescope Chamber Environmental Control Systems, and the Temperature Monitoring System. In addition it will integrate the Power Energy Management System and several service systems such as heating, ventilation, and air conditioning (HVAC), the Domestic Water Distribution System, and the Vacuum System. All of these subsystems must operate in coordination to provide the best possible observing conditions and overall building management. Further, the FMS must actively react to varying weather conditions and observational requirements. The physical impact of the facility must not interfere with neighboring installations while operating in a very environmentally and culturally sensitive area. The FMS system will be comprised of five Programmable Automation Controllers (PACs). We present a pre-build overview of the functional plan to integrate all of the FMS subsystems.

  18. FRACTURING FLUID CHARACTERIZATION FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    Subhash Shah

    2000-08-01

    Hydraulic fracturing technology has been successfully applied for well stimulation of low and high permeability reservoirs for numerous years. Treatment optimization and improved economics have always been the key to the success and it is more so when the reservoirs under consideration are marginal. Fluids are widely used for the stimulation of wells. The Fracturing Fluid Characterization Facility (FFCF) has been established to provide the accurate prediction of the behavior of complex fracturing fluids under downhole conditions. The primary focus of the facility is to provide valuable insight into the various mechanisms that govern the flow of fracturing fluids and slurries through hydraulically created fractures. During the time between September 30, 1992, and March 31, 2000, the research efforts were devoted to the areas of fluid rheology, proppant transport, proppant flowback, dynamic fluid loss, perforation pressure losses, and frictional pressure losses. In this regard, a unique above-the-ground fracture simulator was designed and constructed at the FFCF, labeled ''The High Pressure Simulator'' (HPS). The FFCF is now available to industry for characterizing and understanding the behavior of complex fluid systems. To better reflect and encompass the broad spectrum of the petroleum industry, the FFCF now operates under a new name of ''The Well Construction Technology Center'' (WCTC). This report documents the summary of the activities performed during 1992-2000 at the FFCF.

  19. Decree no. 2010-402 from April 23, 2010, giving permission to Electricite de France to create, on the territory of the town of Saint-Vulbas (Ain, France), a basic nuclear facility named activated waste conditioning and storage facility (ICEDA); Decret no. 2010-402 du 23 avril 2010 autorisant Electricite de France a creer, sur le territoire de la commune de Saint-Vulbas (departement de l'Ain), une installation nucleaire de base denommee Installation de conditionnement et d'entreposage de dechets actives (ICEDA)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    The purpose of the nuclear facility named 'activated waste conditioning and storage facility' (ICEDA) is to process and store the wastes generated by the dismantlement of the Creys-Malville nuclear power plant (Superphenix reactor), and those generated by the exploitation, maintenance and modification of the PWR power plants of Electricite de France (EdF). The facility comprises a reception/evacuation hall, a processing unit, a waste storage building, an effluent treatment plant and some annexe buildings with offices and technical workshops. Wastes are of 3 type: medium activity/long living, low to medium activity/short living, and low activity/long living. The facility ensures the storage of the Chooz A power plant source rods as well. This decree defines the specifications of the facility in the following domains: confinement of radioactive or toxic compounds, protection against internal and external risks (fire hazards, explosions, earthquakes, other environmental risks), exploitation of the facility, management of liquid and gaseous effluents and other wastes generated by the facility. (J.S.)

  20. KONTEC 2011. 10{sup th} international symposium on 'Conditioning of radioactive operational and decommissioning waste' and 10{sup th} BMBF status report on 'Decommissioning and demolition of nuclear facilities'; KONTEC 2011. 10. Internationales Symposium 'Konditionierung radioaktiver Betriebs- und Stilllegungsabfaelle' einschliesslich 10. Statusbericht des BMBF 'Stilllegung und Rueckbau kerntechnischer Anlagen'

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2011-12-15

    KONTEC 2011 was held in Dresden on April 6-8, 2011. The tenth event organized under this heading dealt with the subjects of 'Conditioning of Radioactive Operational and Decommissioning Waste' and 'Decommissioning and Demolition of Nuclear Facilities' including the R and D Status Report by the Federal Ministry of Education and Research (BMBF) on the same subject. The conference was attended by an international audience. The program included plenary sessions on these four key topics: - Disposal of Radioactive Residues from Nuclear Facilities' Operation and Decommissioning. - Decommissioning and Dismantling of Nuclear Facilities. - Facilities and Systems for the Conditioning of Operational and Decommissioning Wastes. - Transport, Interim and Final Storage of Non-heat Generating Wastes (i.e. Konrad). These sessions were accompanied by poster sessions and short presentations under the heading of 'Kontec Direct.' (orig.)

  1. PSL Icing Facility Upgrade Overview

    Science.gov (United States)

    Griffin, Thomas A.; Dicki, Dennis J.; Lizanich, Paul J.

    2014-01-01

    The NASA Glenn Research Center Propulsion Systems Lab (PSL) was recently upgraded to perform engine inlet ice crystal testing in an altitude environment. The system installed 10 spray bars in the inlet plenum for ice crystal generation using 222 spray nozzles. As an altitude test chamber, the PSL is capable of simulating icing events at altitude in a groundtest facility. The system was designed to operate at altitudes from 4,000 to 40,000 ft at Mach numbers up to 0.8M and inlet total temperatures from -60 to +15 degF. This paper and presentation will be part of a series of presentations on PSL Icing and will cover the development of the icing capability through design, developmental testing, installation, initial calibration, and validation engine testing. Information will be presented on the design criteria and process, spray bar developmental testing at Cox and Co., system capabilities, and initial calibration and engine validation test. The PSL icing system was designed to provide NASA and the icing community with a facility that could be used for research studies of engine icing by duplicating in-flight events in a controlled ground-test facility. With the system and the altitude chamber we can produce flight conditions and cloud environments to simulate those encountered in flight. The icing system can be controlled to set various cloud uniformities, droplet median volumetric diameter (MVD), and icing water content (IWC) through a wide variety of conditions. The PSL chamber can set altitudes, Mach numbers, and temperatures of interest to the icing community and also has the instrumentation capability of measuring engine performance during icing testing. PSL last year completed the calibration and initial engine validation of the facility utilizing a Honeywell ALF502-R5 engine and has duplicated in-flight roll back conditions experienced during flight testing. This paper will summarize the modifications and buildup of the facility to accomplish these tests.

  2. Materiel Evaluation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — CRREL's Materiel Evaluation Facility (MEF) is a large cold-room facility that can be set up at temperatures ranging from −20°F to 120°F with a temperature change...

  3. Integrated Disposal Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Located near the center of the 586-square-mile Hanford Site is the Integrated Disposal Facility, also known as the IDF.This facility is a landfill similar in concept...

  4. Environmental Toxicology Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Fully-equipped facilities for environmental toxicology researchThe Environmental Toxicology Research Facility (ETRF) located in Vicksburg, MS provides over 8,200 ft...

  5. Explosive Components Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The 98,000 square foot Explosive Components Facility (ECF) is a state-of-the-art facility that provides a full-range of chemical, material, and performance analysis...

  6. Dialysis Facility Compare

    Data.gov (United States)

    U.S. Department of Health & Human Services — Dialysis Facility Compare helps you find detailed information about Medicare-certified dialysis facilities. You can compare the services and the quality of care that...

  7. Armament Technology Facility (ATF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Armament Technology Facility is a 52,000 square foot, secure and environmentally-safe, integrated small arms and cannon caliber design and evaluation facility....

  8. Cold Vacuum Drying Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Located near the K-Basins (see K-Basins link) in Hanford's 100 Area is a facility called the Cold Vacuum Drying Facility (CVDF).Between 2000 and 2004, workers at the...

  9. Lesotho - Health Facility Survey

    Data.gov (United States)

    Millennium Challenge Corporation — The main objective of the 2011 Health Facility Survey (HFS) was to establish a baseline for informing the Health Project performance indicators on health facilities,...

  10. Ouellette Thermal Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Thermal Test Facility is a joint Army/Navy state-of-the-art facility (8,100 ft2) that was designed to:Evaluate and characterize the effect of flame and thermal...

  11. Projectile Demilitarization Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Projectile Wash Out Facility is US Army Ammunition Peculiar Equipment (APE 1300). It is a pilot scale wash out facility that uses high pressure water and steam...

  12. Wastewater Treatment Facilities

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Individual permits for municipal, industrial, and semi-public wastewater treatment facilities in Iowa for the National Pollutant Discharge Elimination System (NPDES)...

  13. Robustness in facility location

    OpenAIRE

    Van Lokven, Sander W.M.

    2009-01-01

    Facility location concerns the placement of facilities, for various objectives, by use of mathematical models and solution procedures. Almost all facility location models that can be found in literature are based on minimizing costs or maximizing cover, to cover as much demand as possible. These models are quite efficient for finding an optimal location for a new facility for a particular data set, which is considered to be constant and known in advance. In a real world situation, input da...

  14. CLEAR test facility

    CERN Multimedia

    Ordan, Julien Marius

    2017-01-01

    A new user facility for accelerator R&D, the CERN Linear Electron Accelerator for Research (CLEAR), started operation in August 2017. CLEAR evolved from the former CLIC Test Facility 3 (CTF3) used by the Compact Linear Collider (CLIC). The new facility is able to host and test a broad range of ideas in the accelerator field.

  15. Office of Science User Facilities Summary Report, Fiscal Year 2015

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-01-01

    The U.S. Department of Energy Office of Science provides the Nation’s researchers with worldclass scientific user facilities to propel the U.S. to the forefront of science and innovation. A user facility is a federally sponsored research facility available for external use to advance scientific or technical knowledge under the following conditions: open, accessible, free, collaborative, competitive, and unique.

  16. Analysis of conditions to safety and radiological protection of Brazilian research particle accelerators facilities; Analise das condicoes de protecao e seguranca radiologicas das instalacoes com aceleradores de particulas na area de pesquisa no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Lourenco, Manuel Jacinto Martins

    2010-07-01

    Eleven institutions of education and research in Brazil use particle accelerators, which fulfill different functions and activities. Currently, these institutions employ a total of fifteen accelerators. In this paper, the object of study is the radiological protection of occupationally exposed individuals, the general public and the radiation safety of particle accelerators. Research facilities with accelerators are classified in categories I and II according to the International Atomic Energy Agency or groups IX and X in accordance with the Brazilian National Commission of Nuclear Energy. Of the 15 accelerators in use for research in Brazil, four belong to category I or group X and eleven belong to category II or group IX. The methodology presented and developed in this work was made through the inspection and assessment of safety and radiological protection of thirteen particle accelerators facilities, and its main purpose was to promote safer use of this practice by following established guidelines for safety and radiological protection. The results presented in this work showed the need to create a program, in our country, for the control of safety and radiological protection of this ionizing radiation practice. (author)

  17. POWER SYSTEMS DEVELOPMENT FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2002-11-01

    This report discusses test campaign GCT4 of the Kellogg Brown & Root, Inc. (KBR) transport reactor train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The transport reactor is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using one of two possible particulate control devices (PCDs). The transport reactor was operated as a pressurized gasifier during GCT4. GCT4 was planned as a 250-hour test run to continue characterization of the transport reactor using a blend of several Powder River Basin (PRB) coals and Bucyrus limestone from Ohio. The primary test objectives were: Operational Stability--Characterize reactor loop and PCD operations with short-term tests by varying coal-feed rate, air/coal ratio, riser velocity, solids-circulation rate, system pressure, and air distribution. Secondary objectives included the following: Reactor Operations--Study the devolatilization and tar cracking effects from transient conditions during transition from start-up burner to coal. Evaluate the effect of process operations on heat release, heat transfer, and accelerated fuel particle heat-up rates. Study the effect of changes in reactor conditions on transient temperature profiles, pressure balance, and product gas composition. Effects of Reactor Conditions on Synthesis Gas Composition--Evaluate the effect of air distribution, steam/coal ratio, solids-circulation rate, and reactor temperature on CO/CO{sub 2} ratio, synthesis gas Lower Heating Value (LHV), carbon conversion, and cold and hot gas efficiencies. Research Triangle Institute (RTI) Direct Sulfur Recovery Process (DSRP) Testing--Provide syngas in support of the DSRP commissioning. Loop Seal Operations--Optimize loop seal operations and investigate increases to previously achieved maximum solids-circulation rate.

  18. Urban School Facilities: An A-Z Primer. IssueTrak: A CEFPI Brief on Educational Facility Issues

    Science.gov (United States)

    DeJong, William S.

    2004-01-01

    This "IssueTrak" addresses the condition of urban school facilities as a matter of great urgency. Facility planners, are committed to working with urban school districts to develop and implement a systematic approach for modernizing aging urban school facilities. The next generation of school children is far too important and valuable to be forced…

  19. Facility Process Conditional Suspension in Domestic Violence Cases Against Women From The Change of Maria Da Penha Law : Why an Alternative Less Rigorous Based Reconciliation to face this evil

    Directory of Open Access Journals (Sweden)

    Márcia Haydée Porto de Carvalho

    2016-06-01

    Full Text Available This paper studies the conditional studies the conditional suspension of the penal process. This institute consist in the suspension of the procedural course by judicial decision for a certain period, provided accused, with the agreement of his defender, accept to fulfil some conditions, due to proposal from the public prosecutor if there are requirements established in the law and after finished the probation period, the process is archived. It shows that Brazilian Court Supreme forbidden application of this institute to domestic violence against the woman cases in 2012. However, it defends that is important create a law establishing that is possible apply the conditional suspension of the process to this cases as an option to the formal punishment, when the victim is living with the accused or she is her friend, with the monitoring of the aggressor for considerable period, when his reeducation will be observed.

  20. Remote oil and gas facility construction--

    Energy Technology Data Exchange (ETDEWEB)

    Wyrick, D.A.; Eschenbach, T.G. (Missouri Univ., Rolla, MO (USA). Dept. of Engineering Management)

    1989-06-01

    The construction of oil and gas facilities on integrated barge units (IBUs) is presented. This technique of construction could be useful in remote wilderness locations. The function of the facilities, alternate construction techniques, and the effects of location and terrain conditions are discussed. Construction costs using the IBU method are estimated to represent a 16% savings in capitol costs over modular construction, and facility startup can be advanced by up to five months. Using an IBU instead of a stickbuilt facility may represent a 44% savings in cost. In addition, maintenance, abandonment, and site rehabilitation are discussed and compared. For every aspect of cost presented, the integrated barge unit offers a less costly alternative. Depending on the specific location, this technique could also represnt less of an impact to the surrounding environment than the more traditional techniques of oil and gas facility construction.

  1. NWFSC OA facility water chemistry - Ocean acidification species exposure experimental facility

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — We have developed a unique facility for conducting high-quality experiments on marine organisms in seawater with controlled carbon chemistry conditions. The...

  2. Facility Measures Magnetic Fields

    Science.gov (United States)

    Honess, Shawn B.; Narvaez, Pablo; Mcauley, James M.

    1991-01-01

    Partly automated facility measures and computes steady near magnetic field produced by object. Designed to determine magnetic fields of equipment to be installed on spacecraft including sensitive magnetometers, with view toward application of compensating fields to reduce interfernece with spacecraft-magnetometer readings. Because of its convenient operating features and sensitivity of its measurements, facility serves as prototype for similar facilities devoted to magnetic characterization of medical equipment, magnets for high-energy particle accelerators, and magnetic materials.

  3. Synchrotron radiation facilities

    CERN Multimedia

    1972-01-01

    Particularly in the past few years, interest in using the synchrotron radiation emanating from high energy, circular electron machines has grown considerably. In our February issue we included an article on the synchrotron radiation facility at Frascati. This month we are spreading the net wider — saying something about the properties of the radiation, listing the centres where synchrotron radiation facilities exist, adding a brief description of three of them and mentioning areas of physics in which the facilities are used.

  4. Composite Structures Manufacturing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Composite Structures Manufacturing Facility specializes in the design, analysis, fabrication and testing of advanced composite structures and materials for both...

  5. GPS Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Global Positioning System (GPS) Test Facility Instrumentation Suite (GPSIS) provides great flexibility in testing receivers by providing operational control of...

  6. Flexible Electronics Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Flexible Electronics Research Facility designs, synthesizes, tests, and fabricates materials and devices compatible with flexible substrates for Army information...

  7. Nonlinear Materials Characterization Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Nonlinear Materials Characterization Facility conducts photophysical research and development of nonlinear materials operating in the visible spectrum to protect...

  8. Mobile Solar Tracker Facility

    Data.gov (United States)

    Federal Laboratory Consortium — NIST's mobile solar tracking facility is used to characterize the electrical performance of photovoltaic panels. It incorporates meteorological instruments, a solar...

  9. Imagery Data Base Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Imagery Data Base Facility supports AFRL and other government organizations by providing imagery interpretation and analysis to users for data selection, imagery...

  10. Universal Drive Train Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This vehicle drive train research facility is capable of evaluating helicopter and ground vehicle power transmission technologies in a system level environment. The...

  11. Proximal Probes Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Proximal Probes Facility consists of laboratories for microscopy, spectroscopy, and probing of nanostructured materials and their functional properties. At the...

  12. Catalytic Fuel Conversion Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility enables unique catalysis research related to power and energy applications using military jet fuels and alternative fuels. It is equipped with research...

  13. Textiles Performance Testing Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Textiles Performance Testing Facilities has the capabilities to perform all physical wet and dry performance testing, and visual and instrumental color analysis...

  14. Manufacturing Demonstration Facility (MDF)

    Data.gov (United States)

    Federal Laboratory Consortium — The U.S. Department of Energy Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory (ORNL) provides a collaborative, shared infrastructure to...

  15. Magnetics Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetics Research Facility houses three Helmholtz coils that generate magnetic fields in three perpendicular directions to balance the earth's magnetic field....

  16. Neutron Therapy Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Neutron Therapy Facility provides a moderate intensity, broad energy spectrum neutron beam that can be used for short term irradiations for radiobiology (cells)...

  17. Target Assembly Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Target Assembly Facility integrates new armor concepts into actual armored vehicles. Featuring the capability ofmachining and cutting radioactive materials, it...

  18. Engine Test Facility (ETF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Air Force Arnold Engineering Development Center's Engine Test Facility (ETF) test cells are used for development and evaluation testing of propulsion systems for...

  19. Pavement Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Comprehensive Environmental and Structural AnalysesThe ERDC Pavement Testing Facility, located on the ERDC Vicksburg campus, was originally constructed to provide an...

  20. Geospatial Data Analysis Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Geospatial application development, location-based services, spatial modeling, and spatial analysis are examples of the many research applications that this facility...

  1. Transonic Experimental Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Transonic Experimental Research Facility evaluates aerodynamics and fluid dynamics of projectiles, smart munitions systems, and sub-munitions dispensing systems;...

  2. DUPIC facility engineering

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. J.; Lee, H. H.; Kim, K. H. and others

    2000-03-01

    The objectives of this study are (1) the refurbishment for PIEF(Post Irradiation Examination Facility) and M6 hot-cell in IMEF(Irradiated Material Examination Facility), (2) the establishment of the compatible facility for DUPIC fuel fabrication experiments which is licensed by government organization, and (3) the establishment of the transportation system and transportation cask for nuclear material between facilities. The report for this project describes following contents, such as objectives, necessities, scope, contents, results of current step, R and D plan in future and etc.

  3. Facility Environmental Management System

    Data.gov (United States)

    Federal Laboratory Consortium — This is the Web site of the Federal Highway Administration's (FHWA's) Turner-Fairbank Highway Research Center (TFHRC) facility Environmental Management System (EMS)....

  4. Materials Characterization Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Materials Characterization Facility enables detailed measurements of the properties of ceramics, polymers, glasses, and composites. It features instrumentation...

  5. Samarbejdsformer og Facilities Management

    DEFF Research Database (Denmark)

    Storgaard, Kresten

    Resultater fra en surveyundersøgelse om fordele og ulemper ved forskellige samarbejdsformer indenfor Facilities Management fremlægges.......Resultater fra en surveyundersøgelse om fordele og ulemper ved forskellige samarbejdsformer indenfor Facilities Management fremlægges....

  6. DUPIC facility engineering

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. S.; Choi, J. W.; Go, W. I.; Kim, H. D.; Song, K. C.; Jeong, I. H.; Park, H. S.; Im, C. S.; Lee, H. M.; Moon, K. H.; Hong, K. P.; Lee, K. S.; Suh, K. S.; Kim, E. K.; Min, D. K.; Lee, J. C.; Chun, Y. B.; Paik, S. Y.; Lee, E. P.; Yoo, G. S.; Kim, Y. S.; Park, J. C.

    1997-09-01

    In the early stage of the project, a comprehensive survey was conducted to identify the feasibility of using available facilities and of interface between those facilities. It was found out that the shielded cell M6 interface between those facilities. It was found out that the shielded cell M6 of IMEF could be used for the main process experiments of DUPIC fuel fabrication in regard to space adequacy, material flow, equipment layout, etc. Based on such examination, a suitable adapter system for material transfer around the M6 cell was engineered. Regarding the PIEF facility, where spent PWR fuel assemblies are stored in an annex pool, disassembly devices in the pool are retrofitted and spent fuel rod cutting and shipping system to the IMEF are designed and built. For acquisition of casks for radioactive material transport between the facilities, some adaptive refurbishment was applied to the available cask (Padirac) based on extensive analysis on safety requirements. A mockup test facility was newly acquired for remote test of DUPIC fuel fabrication process equipment prior to installation in the M6 cell of the IMEF facility. (author). 157 refs., 57 tabs., 65 figs.

  7. Biotechnology Facility: An ISS Microgravity Research Facility

    Science.gov (United States)

    Gonda, Steve R.; Tsao, Yow-Min

    2000-01-01

    The International Space Station (ISS) will support several facilities dedicated to scientific research. One such facility, the Biotechnology Facility (BTF), is sponsored by the Microgravity Sciences and Applications Division (MSAD) and developed at NASA's Johnson Space Center. The BTF is scheduled for delivery to the ISS via Space Shuttle in April 2005. The purpose of the BTF is to provide: (1) the support structure and integration capabilities for the individual modules in which biotechnology experiments will be performed, (2) the capability for human-tended, repetitive, long-duration biotechnology experiments, and (3) opportunities to perform repetitive experiments in a short period by allowing continuous access to microgravity. The MSAD has identified cell culture and tissue engineering, protein crystal growth, and fundamentals of biotechnology as areas that contain promising opportunities for significant advancements through low-gravity experiments. The focus of this coordinated ground- and space-based research program is the use of the low-gravity environment of space to conduct fundamental investigations leading to major advances in the understanding of basic and applied biotechnology. Results from planned investigations can be used in applications ranging from rational drug design and testing, cancer diagnosis and treatments and tissue engineering leading to replacement tissues.

  8. Sn-PILC: A novel Efficient and Recyclable Catalyst for One-pot Three Component Povarov’s Inverse-electron-demand Hetero Diels-Alder Reaction for a Facile Synthesis of Tetrahydropyranoquinoline Derivatives under Neat Conditions

    Directory of Open Access Journals (Sweden)

    Megha Rai

    2016-07-01

    Full Text Available The Povarov’s inverse-electron-demand hetero Diels–Alder one-pot three components reaction of aromatic aldehyde, aromatic amine with DHF has been developed using Sn-PILC as a catalyst under a neat condition which may helpful to society to get pharmacologically more active compounds. In the present study a novel series of tetrahydroquinoline 4(a-f were synthesized and characterized by IR, 1HNMR, 13CNMR, Mass spectral analysis and elemental analysis. The synthetic details and characterization results are discussed. DOI: http://dx.doi.org/10.17807/orbital.v8i3.801

  9. EPM - The European Facility for human physiology research on ISS.

    Science.gov (United States)

    Rieschel, Mats; Nasca, Rosario; Junk, Peter; Gerhard, Ingo

    2002-07-01

    The European Physiology Modules (EPM) Facility is one of the four major Space Station facilities being developed within the framework of ESA's Microgravity Facilities for Columbus (MFC) programme. In order to allow a wide spectrum of physiological studies in weightlessness conditions, the facility provides the infrastructure to accommodate a variable set of scientific equipment. The initial EPM configuration supports experiments in the fields of neuroscience, bone & muscle research, cardiovascular research and metabolism. The International Space Life Science Working Group (ISLSWG) has recommended co-locating EPM with the 2 NASA Human Research Facility racks.

  10. Wind Energy Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Office of Energy Efficiency and Renewable Energy

    2017-02-01

    This book takes readers inside the places where daily discoveries shape the next generation of wind power systems. Energy Department laboratory facilities span the United States and offer wind research capabilities to meet industry needs. The facilities described in this book make it possible for industry players to increase reliability, improve efficiency, and reduce the cost of wind energy -- one discovery at a time. Whether you require blade testing or resource characterization, grid integration or high-performance computing, Department of Energy laboratory facilities offer a variety of capabilities to meet your wind research needs.

  11. Sustainable Facilities Management

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev; Elle, Morten; Hoffmann, Birgitte

    2004-01-01

    The Danish public housing sector has more than 20 years of experience with sustainable facilities management based on user involvement. The paper outlines this development in a historical perspective and gives an analysis of different approaches to sustainable facilities management. The focus...... is on the housing departments and strateies for the management of the use of resources. The research methods used are case studies based on interviews in addition to literature studies. The paper explores lessons to be learned about sustainable facilities management in general, and points to a need for new...

  12. Facility Modeling Capability Demonstration Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Key, Brian P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sadasivan, Pratap [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fallgren, Andrew James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Demuth, Scott Francis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Aleman, Sebastian E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); de Almeida, Valmor F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Chiswell, Steven R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hamm, Larry [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Tingey, Joel M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-02-01

    A joint effort has been initiated by Los Alamos National Laboratory (LANL), Oak Ridge National Laboratory (ORNL), Savanah River National Laboratory (SRNL), Pacific Northwest National Laboratory (PNNL), sponsored by the National Nuclear Security Administration’s (NNSA’s) office of Proliferation Detection, to develop and validate a flexible framework for simulating effluents and emissions from spent fuel reprocessing facilities. These effluents and emissions can be measured by various on-site and/or off-site means, and then the inverse problem can ideally be solved through modeling and simulation to estimate characteristics of facility operation such as the nuclear material production rate. The flexible framework called Facility Modeling Toolkit focused on the forward modeling of PUREX reprocessing facility operating conditions from fuel storage and chopping to effluent and emission measurements.

  13. FY11 Facility Assessment Study for Aeronautics Test Program

    Science.gov (United States)

    Loboda, John A.; Sydnor, George H.

    2013-01-01

    This paper presents the approach and results for the Aeronautics Test Program (ATP) FY11 Facility Assessment Project. ATP commissioned assessments in FY07 and FY11 to aid in the understanding of the current condition and reliability of its facilities and their ability to meet current and future (five year horizon) test requirements. The principle output of the assessment was a database of facility unique, prioritized investments projects with budgetary cost estimates. This database was also used to identify trends for the condition of facility systems.

  14. Powder Metallurgy Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The facility is uniquely equipped as the only laboratory within DA to conduct PM processing of refractory metals and alloys as well as the processing of a wide range...

  15. Ballistic Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Ballistic Test Facility is comprised of two outdoor and one indoor test ranges, which are all instrumented for data acquisition and analysis. Full-size aircraft...

  16. Laser Guidance Analysis Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility, which provides for real time, closed loop evaluation of semi-active laser guidance hardware, has and continues to be instrumental in the development...

  17. Waste Water Facilities

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset contains the locations of municipal and industrial direct discharge wastewater treatment facilities throughout the state of Vermont. Spatial data is not...

  18. Dialysis Facility Compare Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — These are the official datasets used on the Medicare.gov Dialysis Facility Compare Website provided by the Centers for Medicare and Medicaid Services. These data...

  19. Mark 1 Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Mark I Test Facility is a state-of-the-art space environment simulation test chamber for full-scale space systems testing. A $1.5M dollar upgrade in fiscal year...

  20. Advanced Microanalysis Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Advanced Microanalysis Facility fully integrates capabilities for chemical and structural analysis of electronic materials and devices for the U.S. Army and DoD....

  1. Air Data Calibration Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility is for low altitude subsonic altimeter system calibrations of air vehicles. Mission is a direct support of the AFFTC mission. Postflight data merge is...

  2. Concrete Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This is a 20,000-sq ft laboratory that supports research on all aspects of concrete and materials technology. The staff of this facility offer wide-ranging expertise...

  3. Coastal Harbors Modeling Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Coastal Harbors Modeling Facility is used to aid in the planning of harbor development and in the design and layout of breakwaters, absorbers, etc.. The goal is...

  4. Coastal Inlet Model Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Coastal Inlet Model Facility, as part of the Coastal Inlets Research Program (CIRP), is an idealized inlet dedicated to the study of coastal inlets and equipped...

  5. Field Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Field Research Facility (FRF) located in Duck, N.C. was established in 1977 to support the U.S. Army Corps of Engineers' coastal engineering mission. The FRF is...

  6. Geophysical Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Geophysical Research Facility (GRF) is a 60 ft long × 22 ft wide × 7 ft deep concrete basin at CRREL for fresh or saltwater investigations and can be temperature...

  7. VT Telecommunication Facilities

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The UtilityTelecom_TELEFAC data layer contains points which are intended to represent the location of telecommunications facilities (towers and/or...

  8. GPS Satellite Simulation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The GPS satellite simulation facility consists of a GPS satellite simulator controlled by either a Silicon Graphics Origin 2000 or PC depending upon unit under test...

  9. Skilled Nursing Facility PPS

    Data.gov (United States)

    U.S. Department of Health & Human Services — Section 4432(a) of the Balanced Budget Act (BBA) of 1997 modified how payment is made for Medicare skilled nursing facility (SNF) services. Effective with cost...

  10. Joint Computing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Raised Floor Computer Space for High Performance ComputingThe ERDC Information Technology Laboratory (ITL) provides a robust system of IT facilities to develop and...

  11. Environmental Test Facility (ETF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Environmental Test Facility (ETF) provides non-isolated shock testing for stand-alone equipment and full size cabinets under MIL-S-901D specifications. The ETF...

  12. Urban Test Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — RTTC has access to various facilities for use in urban testing applications,including an agreement with the Hazardous Devices School (HDS): a restrictedaccess Urban...

  13. Electra Laser Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: The Electra Laser Facility is used to develop the science and technology needed to develop a reliable, efficient, high-energy, repetitively pulsed krypton...

  14. Robotics Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This 60 feet x 100 feet structure on the grounds of the Fort Indiantown Gap Pennsylvania National Guard (PNG) Base is a mixed-use facility comprising office space,...

  15. The Birmingham Irradiation Facility

    CERN Document Server

    Dervan, P; Hodgson, P; Marin-Reyes, H; Wilson, J

    2013-01-01

    At the end of 2012 the proton irradiation facility at the CERN PS [1] will shut down for two years. With this in mind, we have been developing a new ATLAS scanning facility at the University of Birmingham Medical Physics cyclotron. With proton beams of energy approximately 30 MeV, fluences corresponding to those of the upgraded Large Hadron Collider (HL-LHC) can be reached conveniently. The facility can be used to irradiate silicon sensors, optical components and mechanical structures (e.g. carbon fibre sandwiches) for the LHC upgrade programme. Irradiations of silicon sensors can be carried out in a temperature controlled cold box that can be scanned through the beam. The facility is described in detail along with the first tests carried out with mini (1 x 1 cm^2 ) silicon sensors.

  16. Climatic Environmental Test Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — RTTC has an extensive suite of facilities for supporting MIL-STD-810 testing, toinclude: Temperature/Altitude, Rapid Decompression, Low/High Temperature,Temperature...

  17. Hypersonic Tunnel Facility (HTF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Hypersonic Tunnel Facility (HTF) is a blow-down, non-vitiated (clean air) free-jet wind tunnel capable of testing large-scale, propulsion systems at Mach 5, 6,...

  18. Wind Tunnel Testing Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — NASA Ames Research Center is pleased to offer the services of our premier wind tunnel facilities that have a broad range of proven testing capabilities to customers...

  19. Chemical Facility Security

    National Research Council Canada - National Science Library

    Schierow, Linda-Jo

    2006-01-01

    .... Because few terrorist attacks have been attempted against chemical facilities in the United States, the risk of death and injury in the near future is estimated to be low, relative to the likelihood...

  20. Liquid Effluent Retention Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Liquid Effluent Retention Facility (LERF) is located in the central part of the Hanford Site. LERF is permitted by the State of Washington and has three liquid...

  1. Airborne & Field Sensors Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — RTTC facilities include an 800' x 60' paved UAV operational area, clearapproach/departure zone, concrete pads furnished with 208VAC, 3 phase,200 amp power, 20,000 sq...

  2. Structural Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides a wide variety of testing equipment, fixtures and facilities to perform both unique aviation component testing as well as common types of materials testing...

  3. Treated Effluent Disposal Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Treated non-hazardous and non-radioactive liquid wastes are collected and then disposed of through the systems at the Treated Effluent Disposal Facility (TEDF). More...

  4. Advanced Microscopy Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides a facility for high-resolution studies of complex biomolecular systems. The goal is an understanding of how to engineer biomolecules for various...

  5. Pit Fragment Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility contains two large (20 foot high by 20 foot diameter) double walled steel tubs in which experimental munitions are exploded while covered with sawdust....

  6. Wind Tunnel Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This ARDEC facility consists of subsonic, transonic, and supersonic wind tunnels to acquire aerodynamic data. Full-scale and sub-scale models of munitions are fitted...

  7. Space Power Facility (SPF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Space Power Facility (SPF) houses the world's largest space environment simulation chamber, measuring 100 ft. in diameter by 122 ft. high. In this chamber, large...

  8. Corrosion Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Corrosion Testing Facility is part of the Army Corrosion Office (ACO). It is a fully functional atmospheric exposure site, called the Corrosion Instrumented Test...

  9. Combustion Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — For more than 30 years The Combustion Research Facility (CRF) has served as a national and international leader in combustion science and technology. The need for a...

  10. Airborne Evaluation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — AFRL's Airborne Evaluation Facility (AEF) utilizes Air Force Aero Club resources to conduct test and evaluation of a variety of equipment and concepts. Twin engine...

  11. Indoor Ground Ejection Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This climate controlled facility is used to evaluate air stores and equipment to determine ejection velocities, store pitch rates, and arming wire and device system...

  12. Hygiene Condition of Water Use and Sanitation Facilities at Urban Slums: Analysis of Port City Chittagong, Bangladesh / Wyposażenie Sanitarne W Slamsach Miejskich - Analiza Na Podstawie Miasta Portowego Chittagong, Bangladesh

    Science.gov (United States)

    Muhit, I. B.; Chowdhury, S. Tasneem; Nahid, Nurangir; Zaman, M. F.

    2015-03-01

    Low income community development is the prerequisite for the overall development of a society. There are different kinds of parameters to widen community development, such as health, economic, social, a living pattern, etc. Sanitation condition is the crucial aspect that is directly or indirectly inter bond with all the parameters. To see the exact reasons behind brutal unhygienic sanitation conditions of water supply and latrine system in a low cost community, the Chittagong City Corporation area has been picked. Relevant data have been collected from field survey, consultancy with inhabitants, Chittagong City Corporation, Power Development Board, and WASA. To know the possible reasons behind the water supply and germ-infested sanitation, state of a low cost community, this paper attempts to shed some light on the tribulations behind the scarcity of safe drinking water, dirt free as well as sustainable latrine and drainage system and offensive water management. Obszary takie jak rozwój gospodarczy, bariery społeczne, standard życia i zdrowie, ściśle związane są ze stanem wyposażenia sanitarnego. W artykule dokonano analizy warunków sanitarnych związanych z zaopatrzeniem w wodę i odprowadzeniem ścieków dla społeczności o niskich dochodach w obszarze Chittagong City Corporation. Dane zostały zebrane podczas ankietowych badań terenowych, rozmów z mieszkańcami, z bazy Chittagong City Corporation, Power Development Board i WASA.

  13. Skilled nursing or rehabilitation facilities

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000435.htm Skilled nursing or rehabilitation facilities To use the sharing features ... facility. Who Needs to go to a Skilled Nursing or Rehabilitation Facility? Your health care provider may ...

  14. National Solar Thermal Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The National Solar Thermal Test Facility (NSTTF) is the only test facility in the United States of its type. This unique facility provides experimental engineering...

  15. Distributed Energy Resources Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — NREL's Distributed Energy Resources Test Facility (DERTF) is a working laboratory for interconnection and systems integration testing. This state-of-the-art facility...

  16. Hanford Facility Dangerous Waste Permit Application, 200 Area Effluent Treatment Facility

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    The 200 Area Effluent Treatment Facility Dangerous Waste Permit Application documentation consists of both Part A and a Part B permit application documentation. An explanation of the Part A revisions associated with this treatment and storage unit, including the current revision, is provided at the beginning of the Part A section. Once the initial Hanford Facility Dangerous Waste Permit is issued, the following process will be used. As final, certified treatment, storage, and/or disposal unit-specific documents are developed, and completeness notifications are made by the US Environmental Protection Agency and the Washington State Department of Ecology, additional unit-specific permit conditions will be incorporated into the Hanford Facility Dangerous Waste Permit through the permit modification process. All treatment, storage, and/or disposal units that are included in the Hanford Facility Dangerous Waste Permit Application will operate under interim status until final status conditions for these units are incorporated into the Hanford Facility Dangerous Waste Permit. The Hanford Facility Dangerous Waste Permit Application, 200 Area Effluent Treatment Facility contains information current as of May 1, 1993.

  17. POWER SYSTEMS DEVELOPMENT FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2002-05-01

    This report discusses test campaign GCT3 of the Halliburton KBR transport reactor train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The transport reactor is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using one of two possible particulate control devices (PCDs). The transport reactor was operated as a pressurized gasifier during GCT3. GCT3 was planned as a 250-hour test run to commission the loop seal and continue the characterization of the limits of operational parameter variations using a blend of several Powder River Basin coals and Bucyrus limestone from Ohio. The primary test objectives were: (1) Loop Seal Commissioning--Evaluate the operational stability of the loop seal with sand and limestone as a bed material at different solids circulation rates and establish a maximum solids circulation rate through the loop seal with the inert bed. (2) Loop Seal Operations--Evaluate the loop seal operational stability during coal feed operations and establish maximum solids circulation rate. Secondary objectives included the continuation of reactor characterization, including: (1) Operational Stability--Characterize the reactor loop and PCD operations with short-term tests by varying coal feed, air/coal ratio, riser velocity, solids circulation rate, system pressure, and air distribution. (2) Reactor Operations--Study the devolatilization and tar cracking effects from transient conditions during transition from start-up burner to coal. Evaluate the effect of process operations on heat release, heat transfer, and accelerated fuel particle heat-up rates. Study the effect of changes in reactor conditions on transient temperature profiles, pressure balance, and product gas composition. (3) Effects of Reactor Conditions on Syngas Composition--Evaluate the effect of air distribution, steam

  18. KONTEC 2013. 11{sup th} international symposium on 'Conditioning of radioactive operational and decommissioning waste' and 11{sup th} BMBF status report on 'Decommissioning and demolition of nuclear facilities'; KONTEC 2013. 11. internationales Symposium 'Konditionierung radioaktiver Betriebs- und Stilllegungsabfaelle' einschliesslich 11. Statusbericht des BMBF 'Stilllegung und Rueckbau kerntechnischer Anlagen'. Veranstaltungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2013-06-15

    KONTEC 2013 was held in Dresden on 13 to 15 March 2013. The 11{sup th} event organized under this heading dealt with the subjects of 'Conditioning of Radioactive Operational and Decommissioning Waste' and 'Decommissioning and Demolition of Nuclear Facilities' including the R and D Status Report by the Federal Ministry of Education and Research (BMBF) on the same subject. The conference was attended by an international audience from 19 countries. The program included plenary sessions on these 4 key topics: - Disposal of Radioactive Residues from Nuclear Facilities' Operation and Decommissioning. - Decommissioning and Dismantling of Nuclear Facilities. - Facilities and Systems for the Conditioning of Operational and Decommissioning Wastes. - Transport, Interim and Final Storage of Non-heat Generating Wastes (i.e. Konrad). These sessions were accompanied by poster sessions and short presentations under the heading of 'Kontec Direct.' The best presentations of the categories Plenary Session Presentation, Poster Presentation and Kontec-Direct have been awarded. In detail, 'Dismantling of Russian nuclear powered submarines' by Detlef Mietann, 'Requalification of 'Old Packages' for the Konrad Repository Described for the Model Case of Packages from Storage Annex A and Repackaging of Containers Holding Compacts in Hall 2 of the GNS Plant' by Martina Koessler, Sebastian Schwall and Pascal Budriks, and 'Electrochemical process development for cleaning organic, C-14-labelled waste solutions' by Hans-Juergen Friedrich. (orig.)

  19. 29 CFR 1917.17 - Railroad facilities.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) MARINE TERMINALS Marine Terminal Operations § 1917.17 Railroad facilities. (a) Work shall be performed in railcars only if floors of the railcars are in visibly safe condition for the work activity... and from places of employment without passing under, over or through railcars, or between cars less...

  20. Comprehensive facilities plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    The Ernest Orlando Lawrence Berkeley National Laboratory`s Comprehensive Facilities Plan (CFP) document provides analysis and policy guidance for the effective use and orderly future development of land and capital assets at the Berkeley Lab site. The CFP directly supports Berkeley Lab`s role as a multiprogram national laboratory operated by the University of California (UC) for the Department of Energy (DOE). The CFP is revised annually on Berkeley Lab`s Facilities Planning Website. Major revisions are consistent with DOE policy and review guidance. Facilities planing is motivated by the need to develop facilities for DOE programmatic needs; to maintain, replace and rehabilitate existing obsolete facilities; to identify sites for anticipated programmatic growth; and to establish a planning framework in recognition of site amenities and the surrounding community. The CFP presents a concise expression of the policy for the future physical development of the Laboratory, based upon anticipated operational needs of research programs and the environmental setting. It is a product of the ongoing planning processes and is a dynamic information source.

  1. Legal regime of water management facilities

    Directory of Open Access Journals (Sweden)

    Salma Jožef

    2013-01-01

    Full Text Available The paper analyzes the legal regime of water management facilities in the light of Serbian, foreign and European law. Different divisions of water management facilities are carried out (to public and private ones, natural and artificial ones, etc., with determination of their legal relevance. Account is taken of the issue of protection from harmful effects of waters to such facilities, as well. The paper points also to rules on the water management facilities, from acts of planning, to individual administrative acts and measures for maintenance of required qualitative and quantitative condition of waters, depending on their purpose (general use or special, commercial use o waters. Albeit special rules on water management facilities exist, due to the natural interlocking between all the components of the environment (water, air and soil, a comprehensive approach is required. A reference is made to other basic principles of protection of water management facilities as well, such as the principle of prevention, principle of sustainable development and the principle "polluter pays". The last one represents the achievement of contemporary law, which deviates from the idea accepted in the second half of 20th century that supported the socialization of risk from harmful effects of waters.

  2. Kauai Test Facility hazards assessment document

    Energy Technology Data Exchange (ETDEWEB)

    Swihart, A

    1995-05-01

    The Department of Energy Order 55003A requires facility-specific hazards assessment be prepared, maintained, and used for emergency planning purposes. This hazards assessment document describes the chemical and radiological hazards associated with the Kauai Test Facility, Barking Sands, Kauai, Hawaii. The Kauai Test Facility`s chemical and radiological inventories were screened according to potential airborne impact to onsite and offsite individuals. The air dispersion model, ALOHA, estimated pollutant concentrations downwind from the source of a release, taking into consideration the toxicological and physical characteristics of the release site, the atmospheric conditions, and the circumstances of the release. The greatest distance to the Early Severe Health Effects threshold is 4.2 kilometers. The highest emergency classification is a General Emergency at the {open_quotes}Main Complex{close_quotes} and a Site Area Emergency at the Kokole Point Launch Site. The Emergency Planning Zone for the {open_quotes}Main Complex{close_quotes} is 5 kilometers. The Emergency Planning Zone for the Kokole Point Launch Site is the Pacific Missile Range Facility`s site boundary.

  3. FACILITIES MANAGEMENT AT CERN

    CERN Multimedia

    2002-01-01

    Recently we have been confronted with difficulties concerning services which are part of a new contract for facilities management. Please see below for some information about this contract. Following competitive tendering and the Finance Committee decision, the contract was awarded to the Swiss firm 'Facilities Management Network (FMN)'. The owners of FMN are two companies 'M+W Zander' and 'Avireal', both very experienced in this field of facilities management. The contract entered into force on 1st July 2002. CERN has grouped together around 20 different activities into this one contract, which was previously covered by separate contracts. The new contract includes the management and execution of many activities, in particular: Guards and access control; cleaning; operation and maintenance of heating plants, cooling and ventilation equipment for buildings not related to the tunnel or the LHC; plumbing; sanitation; lifts; green areas and roads; waste disposal; and includes a centralised helpdesk for these act...

  4. Preliminary design for a maglev development facility

    Energy Technology Data Exchange (ETDEWEB)

    Coffey, H.T.; He, J.L.; Chang, S.L.; Bouillard, J.X.; Chen, S.S.; Cai, Y.; Hoppie, L.O.; Lottes, S.A.; Rote, D.M. (Argonne National Lab., IL (United States)); Zhang, Z.Y. (Polytechnic Univ., Brooklyn, NY (United States)); Myers, G.; Cvercko, A. (Sterling Engineering, Westchester, IL (United States)); Williams, J.R. (Alfred Benesch and Co., Chicago, IL (United States))

    1992-04-01

    A preliminary design was made of a national user facility for evaluating magnetic-levitation (maglev) technologies in sizes intermediate between laboratory experiments and full-scale systems. A technical advisory committee was established and a conference was held to obtain advice on the potential requirements of operational systems and how the facility might best be configured to test these requirements. The effort included studies of multiple concepts for levitating, guiding, and propelling maglev vehicles, as well as the controls, communications, and data-acquisition and -reduction equipment that would be required in operating the facility. Preliminary designs for versatile, dual 2-MVA power supplies capable of powering attractive or repulsive systems were developed. Facility site requirements were identified. Test vehicles would be about 7.4 m (25 ft) long, would weigh form 3 to 7 metric tons, and would operate at speeds up to 67 m/s (150 mph) on a 3.3-km (2.05-mi) elevated guideway. The facility would utilize modular vehicles and guideways, permitting the substitution of levitation, propulsion, and guideway components of different designs and materials for evaluation. The vehicle would provide a test cell in which individual suspension or propulsion components or subsystems could be tested under realistic conditions. The system would allow economical evaluation of integrated systems under varying weather conditions and in realistic geometries.

  5. Competitive facility location models

    Science.gov (United States)

    Kononov, A. V.; Kochetov, Yu. A.; Plyasunov, A. V.

    2009-06-01

    Two classes of competitive facility location models are considered, in which several persons (players) sequentially or simultaneously open facilities for serving clients. The first class consists of discrete two-level programming models. The second class consists of game models with several independent players pursuing selfish goals. For the first class, its relationship with pseudo-Boolean functions is established and a novel method for constructing a family of upper and lower bounds on the optimum is proposed. For the second class, the tight PLS-completeness of the problem of finding Nash equilibriums is proved.

  6. Robust facility location

    OpenAIRE

    Carrizosa Priego, Emilio José; Nickel, Stefan

    2003-01-01

    Let A be a nonempty finite subset of the plane representing the geographical coordinates of a set of demand points (towns, …), to be served by a facility, whose location within a given region S is sought. Assuming that the unit cost for a∈A if the facility is located at x∈S is proportional to dist(x,a) — the distance from x to a — and that demand of point a is given by ωa, minimizing the total transportation cost TC(ω,x) amounts to solving the Weber problem. In practice, it may be the case, h...

  7. Features of changes periglacial formation in the zone of transport facilities (for example Dneprodzerzhinsk.

    Directory of Open Access Journals (Sweden)

    Mokritskaya T.

    2013-09-01

    Full Text Available The regularities of variability geological conditions in the zone of transport facilities in the areas of technological soaking and strains.The criteria of disorders of the array in the zone of influence of the transport facilities.

  8. The two-level uncapacitated facility location problem

    Energy Technology Data Exchange (ETDEWEB)

    Leung, J.; Aardal, K.; Labbe, M.; Queyranne, M.

    1994-12-31

    We study the problem of locating facilities and depots, and assigning clients to facility-depot pairs. We characterize the extreme points of the LP-relaxation and discuss different initial formulations. Conditions whereby facets for the one-level problem define facets for the two-level problem are given and several new classes of facets are introduced.

  9. Coincident optima for two-facility Weber problems

    DEFF Research Database (Denmark)

    Juel, Henrik

    1983-01-01

    The location problem with two new facilities in continuous space is considered, with distance measured by arbitrary norms. Necessary and sufficient conditions for a proposed solution to be optimal are given for several cases. These cases include situations where the cost function...... is nondifferentiable because facilities coincide...

  10. Facility overview for commercial application of selected Rocky Flats facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    The purpose of this Facility Overview is to support the Rocky Flats Local Impacts Initiative`s Request for Interest, to solicit interest from commercial corporations for utilizing buildings 865 and 883, and the equipment contained within each building, for a commercial venture. In the following sections, this document describes the Rocky Flats Site, the buildings available for lease, the equipment within these buildings, the site services available to a tenant, the human resources available to support operations in buildings 865 and 883, and the environmental condition of the buildings and property. In addition, a brief description is provided of the work performed to date to explore the potential products that might be manufactured in Buildings 865 and 883, and the markets for these products.

  11. National geothermal test facility

    Energy Technology Data Exchange (ETDEWEB)

    1976-03-01

    A brief description of the East Mesa test site is given. The test facility is supplied by brines from three of the existing production wells, each brine having distinctive physical characteristics. Some of the experimental programs involving heat exchangers and power cycles are briefly discussed. These include binary fluid cycles, two-phase expansion cycles, and combination cycles. (MOW)

  12. Mineral facilities of Europe

    Science.gov (United States)

    Almanzar, Francisco; Baker, Michael S.; Elias, Nurudeen; Guzman, Eric

    2010-01-01

    This map displays over 1,700 records of mineral facilities within the countries of Europe and western Eurasia. Each record represents one commodity and one facility type at a single geographic location. Facility types include mines, oil and gas fields, and plants, such as refineries, smelters, and mills. Common commodities of interest include aluminum, cement, coal, copper, gold, iron and steel, lead, nickel, petroleum, salt, silver, and zinc. Records include attributes, such as commodity, country, location, company name, facility type and capacity (if applicable), and latitude and longitude geographical coordinates (in both degrees-minutes-seconds and decimal degrees). The data shown on this map and in table 1 were compiled from multiple sources, including (1) the most recently available data from the U.S. Geological Survey (USGS) Minerals Yearbook (Europe and Central Eurasia volume), (2) mineral statistics and information from the USGS Minerals Information Web site (http://minerals.usgs.gov/minerals/pubs/country/europe.html), and (3) data collected by the USGS minerals information country specialists from sources, such as statistical publications of individual countries, annual reports and press releases of operating companies, and trade journals. Data reflect the most recently published table of industry structure for each country at the time of this publication. Additional information is available from the country specialists listed in table 2.

  13. Facilities of Environmental Distinction

    Science.gov (United States)

    Pascopella, Angela

    2011-01-01

    Three of nine school buildings that have won the latest Educational Facility Design Awards from the American Institute of Architects (AIA) Committee on Architecture for Education stand out from the crowd of other school buildings because they are sustainable and are connected to the nature that surrounds them. They are: (1) Thurston Elementary…

  14. Facility effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gleckler, B.P.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the facility effluent monitoring programs and provides an evaluation of effluent monitoring data. These evaluations are useful in assessing the effectiveness of effluent treatment and control systems, as well as management practices.

  15. Variable gravity research facility

    Science.gov (United States)

    Allan, Sean; Ancheta, Stan; Beine, Donna; Cink, Brian; Eagon, Mark; Eckstein, Brett; Luhman, Dan; Mccowan, Daniel; Nations, James; Nordtvedt, Todd

    1988-01-01

    Spin and despin requirements; sequence of activities required to assemble the Variable Gravity Research Facility (VGRF); power systems technology; life support; thermal control systems; emergencies; communication systems; space station applications; experimental activities; computer modeling and simulation of tether vibration; cost analysis; configuration of the crew compartments; and tether lengths and rotation speeds are discussed.

  16. SHORT COMMUNICATION FACILE ENANTIOSELECTIVE ...

    African Journals Online (AJOL)

    FACILE ENANTIOSELECTIVE PALLADIUM CATALYSED TRANSFER. HYDROGENATION OF α-METHYLCINNAMIC ACID IN THE PRESENCE OF. OPTICAL PURE ORGANIC ACIDS. Reginah N. Bwire, Runner R. T. Majinda and Ishmael B. Masesane*. Chemistry Department, University of Botswana, P/Bag UB00704, ...

  17. Optimal Facility-Location.

    Science.gov (United States)

    Goldman, A J

    2006-01-01

    Dr. Christoph Witzgall, the honoree of this Symposium, can count among his many contributions to applied mathematics and mathematical operations research a body of widely-recognized work on the optimal location of facilities. The present paper offers to non-specialists a sketch of that field and its evolution, with emphasis on areas most closely related to Witzgall's research at NBS/NIST.

  18. Platinum recovery from used auto catalytic converters in electrorefining process

    Directory of Open Access Journals (Sweden)

    A. Fornalczyk

    2013-04-01

    Full Text Available This paper presents possibility of removing platinum from the used catalytic converters applying copper as a metal collector in pyrometallurgical methods. The catalytic converter carrier was grinded and melted with copper. During the research obtained Cu-Pt alloy was casted as an anode. Such anode was electrically refined in order to recover platinum. Obtained results were discussed.

  19. Technical Safety Requirements for the Gamma Irradiation Facility (GIF)

    CERN Document Server

    Mahn, J A E M J G

    2003-01-01

    This document provides the Technical Safety Requirements (TSR) for the Sandia National Laboratories Gamma Irradiation Facility (GIF). The TSR is a compilation of requirements that define the conditions, the safe boundaries, and the administrative controls necessary to ensure the safe operation of a nuclear facility and to reduce the potential risk to the public and facility workers from uncontrolled releases of radioactive or other hazardous materials. These requirements constitute an agreement between DOE and Sandia National Laboratories management regarding the safe operation of the Gamma Irradiation Facility.

  20. High-field conductor testing at the FENIX facility

    Science.gov (United States)

    Shen, S. S.; Chaplin, M. R.; Felker, B.; Hassenzahl, W. V.; Kishiyama, K. I.; Parker, J. M.

    1993-04-01

    The Fusion Engineering International experiments (FENIX) Test Facility, which was commissioned at the end of 1991, is the first facility in the world capable of testing prototype conductors for the International Thermonuclear Experimental Reactor (ITER) superconducting magnets. The FENIX facility provides test conditions that simulate the ITER magnet operating environment; more importantly, it also accommodates specific experiments to determine the operational margins for the prototype conductors. The FENIX facility generates magnetic fields close to 14 T, and transport currents over 40 kA for testing the prototype conductors. This paper describes an experimental program that measures critical currents, current-sharing temperatures, forced-flow properties, and cyclic effects.

  1. 42 CFR 483.430 - Condition of participation: Facility staffing.

    Science.gov (United States)

    2010-10-01

    ... in psychology from an accredited school. (vi) To be designated as a social worker, an individual must...: sociology, special education, rehabilitation counseling, and psychology). (xi) If the client's individual... psychotic-like behavior, the staff to client ratio is 1 to 3.2. (ii) For each defined residential living...

  2. Fast Flux Test Facility project plan. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    Hulvey, R.K.

    1995-11-01

    The Fast Flux Test Facility (FFTF) Transition Project Plan, Revision 2, provides changes to the major elements and project baseline for the deactivation activities necessary to transition the FFTF to a radiologically and industrially safe shutdown condition.

  3. Operational Safety Requirements Neutron Multiplier Facility in 329 Building

    Energy Technology Data Exchange (ETDEWEB)

    EA. Lepel

    1992-10-01

    The operational safety requirements (OSRs) presented in this report define the conditions, safe boundaries and management control needed for safely operating the Neutron Multiplier Facility in the 329 Building Annex.

  4. Direct Connect Supersonic Combustion Facility (Research Cell 22)

    Data.gov (United States)

    Federal Laboratory Consortium — Description: RC22 is a continuous-flow, direct-connect supersonic-combustion research facility that is capable of simulating flight conditions from Mach 3.0 to Mach...

  5. EBR-II Breached Fuel Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Lehto, W K; Koenig, J F; Seim, O S; Olp, R H; Strain, R V; Colburn, R P

    1979-01-01

    The Breached Fuel Test Facility (BFTF) is a multipurpose experimental facility, designed to provide the capability to conduct and monitor safety and fuel behavior experiments under move severe conditions than previously allowed in EBR-II. The facility consists of an outer thimble assembly with an internal instrument stalk which extends from the reactor floor through the primary tank cover to the top of the core. Coolant from a breached element test is directed upward to the instrument train above the core. The BFTF has the capability to measure flow, temperature, particle size distribution and deposition, and delayed neutron levels for breach site characterization. This paper describes the design, the instrumentation, the operational safety concerns and the initial experiments.

  6. Wireless remote monitoring of critical facilities

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, Hanchung; Anderson, John T.; Liu, Yung Y.

    2016-12-13

    A method, apparatus, and system are provided for monitoring environment parameters of critical facilities. A Remote Area Modular Monitoring (RAMM) apparatus is provided for monitoring environment parameters of critical facilities. The RAMM apparatus includes a battery power supply and a central processor. The RAMM apparatus includes a plurality of sensors monitoring the associated environment parameters and at least one communication module for transmitting one or more monitored environment parameters. The RAMM apparatus is powered by the battery power supply, controlled by the central processor operating a wireless sensor network (WSN) platform when the facility condition is disrupted. The RAMM apparatus includes a housing prepositioned at a strategic location, for example, where a dangerous build-up of contamination and radiation may preclude subsequent manned entrance and surveillance.

  7. EPA Facility Registry Service (FRS): Facility Interests Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in...

  8. EPA Facility Registry Service (FRS): Facility Interests Dataset - Intranet

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in...

  9. EPA Facility Registry Service (FRS): Facility Interests Dataset Download

    Data.gov (United States)

    U.S. Environmental Protection Agency — This downloadable data package consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are...

  10. EPA Facility Registry Service (FRS): AIRS_AFS Sub Facilities

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Facility System (AFS) contains compliance and permit data for stationary sources regulated by EPA, state and local air pollution agencies. The sub facility...

  11. EPA Facility Registry Service (FRS): Facility Interests Dataset - Intranet Download

    Data.gov (United States)

    U.S. Environmental Protection Agency — This downloadable data package consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are...

  12. Safeguards Approaches for Black Box Processes or Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Diaz-Marcano, Helly; Gitau, Ernest TN; Hockert, John; Miller, Erin; Wylie, Joann

    2013-09-25

    The objective of this study is to determine whether a safeguards approach can be developed for “black box” processes or facilities. These are facilities where a State or operator may limit IAEA access to specific processes or portions of a facility; in other cases, the IAEA may be prohibited access to the entire facility. The determination of whether a black box process or facility is safeguardable is dependent upon the details of the process type, design, and layout; the specific limitations on inspector access; and the restrictions placed upon the design information that can be provided to the IAEA. This analysis identified the necessary conditions for safeguardability of black box processes and facilities.

  13. Universal Test Facility

    Science.gov (United States)

    Laughery, Mike

    A universal test facility (UTF) for Space Station Freedom is developed. In this context, universal means that the experimental rack design must be: automated, highly marketable, and able to perform diverse microgravity experiments according to NASA space station requirements. In order to fulfill these broad objectives, the facility's customers, and their respective requirements, are first defined. From these definitions, specific design goals and the scope of the first phase of this project are determined. An examination is first made into what types of research are most likely to make the UTF marketable. Based on our findings, the experiments for which the UTF would most likely be used included: protein crystal growth, hydroponics food growth, gas combustion, gallium arsenide crystal growth, microorganism development, and cell encapsulation. Therefore, the UTF is designed to fulfill all of the major requirements for the experiments listed above. The versatility of the design is achieved by taking advantage of the many overlapping requirements presented by these experiments.

  14. World Class Facilities Management

    DEFF Research Database (Denmark)

    Malmstrøm, Ole Emil; Jensen, Per Anker

    2013-01-01

    Alle der med entusiasme arbejder med Facilities Management drømmer om at levere World Class. DFM drømmer om at skabe rammer og baggrund for, at vi i Danmark kan bryste os at være blandt de førende på verdensplan. Her samles op på, hvor tæt vi er på at nå drømmemålet.......Alle der med entusiasme arbejder med Facilities Management drømmer om at levere World Class. DFM drømmer om at skabe rammer og baggrund for, at vi i Danmark kan bryste os at være blandt de førende på verdensplan. Her samles op på, hvor tæt vi er på at nå drømmemålet....

  15. The ISOLDE facility

    Science.gov (United States)

    Catherall, R.; Andreazza, W.; Breitenfeldt, M.; Dorsival, A.; Focker, G. J.; Gharsa, T. P.; J, Giles T.; Grenard, J.-L.; Locci, F.; Martins, P.; Marzari, S.; Schipper, J.; Shornikov, A.; Stora, T.

    2017-09-01

    The ISOLDE facility has undergone numerous changes over the last 17 years driven by both the physics and technical community with a common goal to improve on beam variety, beam quality and safety. Improvements have been made in civil engineering and operational equipment while continuing developments aim to ensure operations following a potential increase in primary beam intensity and energy. This paper outlines the principal technical changes incurred at ISOLDE by building on a similar publication of the facility upgrades by Kugler (2000 Hyperfine Interact. 129 23–42). It also provides an insight into future perspectives through a brief summary issues addressed in the HIE-ISOLDE design study Catherall et al (2013 Nucl. Instrum. Methods Phys. Res. B 317 204–207).

  16. The NASA Lewis Research Center Internal Fluid Mechanics Facility

    Science.gov (United States)

    Porro, A. R.; Hingst, W. R.; Wasserbauer, C. A.; Andrews, T. B.

    1991-01-01

    An experimental facility specifically designed to investigate internal fluid duct flows is described. It is built in a modular fashion so that a variety of internal flow test hardware can be installed in the facility with minimal facility reconfiguration. The facility and test hardware interfaces are discussed along with design constraints of future test hardware. The plenum flow conditioning approach is also detailed. Available instrumentation and data acquisition capabilities are discussed. The incoming flow quality was documented over the current facility operating range. The incoming flow produces well behaved turbulent boundary layers with a uniform core. For the calibration duct used, the boundary layers approached 10 percent of the duct radius. Freestream turbulence levels at the various operating conditions varied from 0.64 to 0.69 percent of the average freestream velocity.

  17. Facility decontamination technology workshop

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-10-01

    Purpose of the meeting was to provide a record of experience at nuclear facilities, other than TMI-2, of events and incidents which have required decontamination and dose reduction activities, and to furnish GPU and others involved in the TMI-2 cleanup with the results of that decontamination and dose reduction technology. Separate abstracts were prepared for 24 of the 25 papers; the remaining paper had been previously abstracted. (DLC)

  18. Japan hadron facility

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Tokushi [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    1998-03-01

    JHF aims at promoting the variety of research fields using various secondary beams produced by high-intensity proton beams. The accelerator of JHF will be an accelerator complex of a 200 MeV LINAC, a 3 GeV booster proton synchrotron, and a 50 GeV proton synchrotron. The four main experimental facilities of K-Arena, M-Arena, N-Arena, and E-Arena are planed. The outline of the project is presented. (author)

  19. Facility Response Plan

    Science.gov (United States)

    1992-10-06

    otherwise described in specialized publications. Identifying and delineating these ESAU will require professional judgment. Categories of...consistent with these broader plans. Also, ensure that the ESAU identified in the ACP are considered in the FRP. Place emphasis on ensuring that the following...section 4.1 requires the identification of Environmentally Sensitive Areas (ESAs). If ESAU are located near the facility, more stringent protective

  20. Future Facilities Summary

    CERN Document Server

    De Roeck, Albert

    2009-01-01

    For the session on future facilities at DIS09 discussions were organized on DIS related measurements that can be expected in the near and medium - or perhaps far - future, including plans from JLab, CERN and FNAL fixed target experiments, possible measurements and detector upgrades at RHIC, as well as the plans for possible future electron proton/ion colliders such as the EIC and the LHeC project.

  1. Future Facilities Summary

    Energy Technology Data Exchange (ETDEWEB)

    Albert De Roeck, Rolf Ent

    2009-10-01

    For the session on future facilities at DIS09 discussions were organized on DIS related measurements that can be expected in the near and medium –or perhaps far– future, including plans from JLab, CERN and FNAL fixed target experiments, possible measurements and detector upgrades at RHIC, as well as the plans for possible future electron proton/ion colliders such as the EIC and the LHeC project.

  2. Optimal Facility-Location

    OpenAIRE

    Goldman, A. J.

    2006-01-01

    Dr. Christoph Witzgall, the honoree of this Symposium, can count among his many contributions to applied mathematics and mathematical operations research a body of widely-recognized work on the optimal location of facilities. The present paper offers to non-specialists a sketch of that field and its evolution, with emphasis on areas most closely related to Witzgall?s research at NBS/NIST.

  3. INTEGRATION OF FACILITY MODELING CAPABILITIES FOR NUCLEAR NONPROLIFERATION ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    Gorensek, M.; Hamm, L.; Garcia, H.; Burr, T.; Coles, G.; Edmunds, T.; Garrett, A.; Krebs, J.; Kress, R.; Lamberti, V.; Schoenwald, D.; Tzanos, C.; Ward, R.

    2011-07-18

    Developing automated methods for data collection and analysis that can facilitate nuclear nonproliferation assessment is an important research area with significant consequences for the effective global deployment of nuclear energy. Facility modeling that can integrate and interpret observations collected from monitored facilities in order to ascertain their functional details will be a critical element of these methods. Although improvements are continually sought, existing facility modeling tools can characterize all aspects of reactor operations and the majority of nuclear fuel cycle processing steps, and include algorithms for data processing and interpretation. Assessing nonproliferation status is challenging because observations can come from many sources, including local and remote sensors that monitor facility operations, as well as open sources that provide specific business information about the monitored facilities, and can be of many different types. Although many current facility models are capable of analyzing large amounts of information, they have not been integrated in an analyst-friendly manner. This paper addresses some of these facility modeling capabilities and illustrates how they could be integrated and utilized for nonproliferation analysis. The inverse problem of inferring facility conditions based on collected observations is described, along with a proposed architecture and computer framework for utilizing facility modeling tools. After considering a representative sampling of key facility modeling capabilities, the proposed integration framework is illustrated with several examples.

  4. Hot Hydrogen Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    W. David Swank

    2007-02-01

    The core in a nuclear thermal rocket will operate at high temperatures and in hydrogen. One of the important parameters in evaluating the performance of a nuclear thermal rocket is specific impulse, ISp. This quantity is proportional to the square root of the propellant’s absolute temperature and inversely proportional to square root of its molecular weight. Therefore, high temperature hydrogen is a favored propellant of nuclear thermal rocket designers. Previous work has shown that one of the life-limiting phenomena for thermal rocket nuclear cores is mass loss of fuel to flowing hydrogen at high temperatures. The hot hydrogen test facility located at the Idaho National Lab (INL) is designed to test suitability of different core materials in 2500°C hydrogen flowing at 1500 liters per minute. The facility is intended to test non-uranium containing materials and therefore is particularly suited for testing potential cladding and coating materials. In this first installment the facility is described. Automated Data acquisition, flow and temperature control, vessel compatibility with various core geometries and overall capabilities are discussed.

  5. Cryogenic Fluid Management Facility

    Science.gov (United States)

    Eberhardt, R. N.; Bailey, W. J.

    1985-01-01

    The Cryogenic Fluid Management Facility is a reusable test bed which is designed to be carried within the Shuttle cargo bay to investigate the systems and technologies associated with the efficient management of cryogens in space. Cryogenic fluid management consists of the systems and technologies for: (1) liquid storage and supply, including capillary acquisition/expulsion systems which provide single-phase liquid to the user system, (2) both passive and active thermal control systems, and (3) fluid transfer/resupply systems, including transfer lines and receiver tanks. The facility contains a storage and supply tank, a transfer line and a receiver tank, configured to provide low-g verification of fluid and thermal models of cryogenic storage and transfer processes. The facility will provide design data and criteria for future subcritical cryogenic storage and transfer system applications, such as Space Station life support, attitude control, power and fuel depot supply, resupply tankers, external tank (ET) propellant scavenging, and ground-based and space-based orbit transfer vehicles (OTV).

  6. Tier II Chemical Storage Facilities

    Data.gov (United States)

    Iowa State University GIS Support and Research FacilityFacilities that store hazardous chemicals above certain quantities must submit an annual emergency and hazardous chemical inventory on a Tier II form. This is a...

  7. New Ideas on Facilities Management.

    Science.gov (United States)

    Grimm, James C.

    1986-01-01

    Examines trends in facilities management relating to products and people. Reviews new trends in products, including processes, techniques, and programs that are being expounded by business and industry. Discusses the "people factors" involved in facilities management. (ABB)

  8. Arc Heated Scramjet Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Arc Heated Scramjet Test Facility is an arc heated facility which simulates the true enthalpy of flight over the Mach number range of about 4.7 to 8 for free-jet...

  9. Emission Facilities - Air Emission Plants

    Data.gov (United States)

    NSGIC Education | GIS Inventory — Represents the Primary Facility type Air Emission Plant (AEP) point features. Air Emissions Plant is a DEP primary facility type related to the Air Quality Program....

  10. IPFQR FUH Quality Measures Facility

    Data.gov (United States)

    U.S. Department of Health & Human Services — Psychiatric facilities that are eligible for the Inpatient Psychiatric Facility Quality Reporting (IPFQR) program are required to meet all program requirements,...

  11. Carbon Fiber Technology Facility (CFTF)

    Data.gov (United States)

    Federal Laboratory Consortium — Functionally within the MDF, ORNL operates DOE’s unique Carbon Fiber Technology Facility (CFTF)—a 42,000 ft2 innovative technology facility and works with leading...

  12. Environmentally Regulated Facilities in Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — A unique record for each facility site with an environmental interest by DNR (such as permits). This brings together core environmental information in one place for...

  13. Tandem Van de Graaff facility

    Data.gov (United States)

    Federal Laboratory Consortium — Completed in 1970, the Tandem Van de Graaff facility was for many years the world's largest electrostatic accelerator facility. It can provide researchers with beams...

  14. Shock Thermodynamic Applied Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Shock Thermodynamic Applied Research Facility (STAR) facility, within Sandia’s Solid Dynamic Physics Department, is one of a few institutions in the world with a...

  15. Nitramine Drying & Fine Grinding Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Nitramine Drying and Fine Grinding Facility provides TACOM-ARDEC with a state-of-the-art facility capable of drying and grinding high explosives (e.g., RDX and...

  16. Indoor Lighting Facilities

    Science.gov (United States)

    Matsushima, Koji; Saito, Yoshinori; Ichikawa, Shigenori; Kawauchi, Takao; Tanaka, Tsuneo; Hirano, Rika; Tazuke, Fuyuki

    According to the statistics by the Ministry of Land, Infrastructure and Transport, the total floor space of all building construction started was 188.87 million m2 (1.5% increase y/y), marking the fourth straight year of increase. Many large-scale buildings under construction in central Tokyo become fully occupied by tenants before completion. As for office buildings, it is required to develop comfortable and functional office spaces as working styles are becoming more and more diversified, and lighting is also an element of such functionalities. The total floor space of construction started for exhibition pavilions, multipurpose halls, conference halls and religious architectures decreased 11.1% against the previous year. This marked a decline for 10 consecutive years and the downward trend continues. In exhibition pavilions, the light radiation is measured and adjusted throughout the year so as not to damage the artworks by lighting. Hospitals, while providing higher quality medical services and enhancing the dwelling environment of patients, are expected to meet various restrictions and requirements, including the respect for privacy. Meanwhile, lighting designs for school classrooms tend to be homogeneous, yet new ideas are being promoted to strike a balance between the economical and functional aspects. The severe economic environment continues to be hampering the growth of theaters and halls in both the private and public sectors. Contrary to the downsizing trend of such facilities, additional installations of lighting equipment were conspicuous, and the adoption of high efficacy lighting appliances and intelligent function control circuits are becoming popular. In the category of stores/commercial facilities, the construction of complex facilities is a continuing trend. Indirect lighting, high luminance discharge lamps with excellent color rendition and LEDs are being effectively used in these facilities, together with the introduction of lighting designs

  17. The Francium facility at TRIUMF

    Science.gov (United States)

    Aubin, S.; Behr, J. A.; Chen, G.; Collister, R.; Flambaum, V. V.; Gomez, E.; Gwinner, G.; Jackson, K. P.; Melconian, D.; Orozco, L. A.; Pearson, M. R.; Ruiz, M. C.; Sheng, D.; Shin, Y. H.; Sprouse, G. D.; Tandecki, M.; Zhang, J.; Zhao, Y.

    2013-04-01

    We present the current status of the Francium Trapping Facility at ISAC at TRIUMF. The facility will enable future experiments on the weak interaction with measurements of atomic parity non-conservation laser-cooled samples of artificially produced francium. These experiments require a precisely controlled environment, which the facility is designed to provide. The facility has been constructed and is being prepared for a series of commissioning runs.

  18. Instrumentation Design and Development Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — RTTC has facilities for design, development and fabrication of: custominstrumentation, mobile instrumentation, miniaturized instrumentation, wirelessinstrumentation,...

  19. Capital Ideas for Facilities Management.

    Science.gov (United States)

    Golding, Stephen T.; Gordon, Janet; Gravina, Arthur

    2001-01-01

    Asserting that just like chief financial officers, higher education facilities specialists must maximize the long-term performance of assets under their care, describes strategies for strategic facilities management. Discusses three main approaches to facilities management (insourcing, cosourcing, and outsourcing) and where boards of trustees fit…

  20. Facilities removal working group

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This working group`s first objective is to identify major economic, technical, and regulatory constraints on operator practices and decisions relevant to offshore facilities removal. Then, the group will try to make recommendations as to regulatory and policy adjustments, additional research, or process improvements and/or technological advances, that may be needed to improve the efficiency and effectiveness of the removal process. The working group will focus primarily on issues dealing with Gulf of Mexico platform abandonments. In order to make the working group sessions as productive as possible, the Facilities Removal Working Group will focus on three topics that address a majority of the concerns and/or constraints relevant to facilities removal. The three areas are: (1) Explosive Severing and its Impact on Marine Life, (2) Pile and Conductor Severing, and (3) Deep Water Abandonments This paper will outline the current state of practice in the offshore industry, identifying current regulations and specific issues encountered when addressing each of the three main topics above. The intent of the paper is to highlight potential issues for panel discussion, not to provide a detailed review of all data relevant to the topic. Before each panel discussion, key speakers will review data and information to facilitate development and discussion of the main issues of each topic. Please refer to the attached agenda for the workshop format, key speakers, presentation topics, and panel participants. The goal of the panel discussions is to identify key issues for each of the three topics above. The working group will also make recommendations on how to proceed on these key issues.

  1. Test Track Facilities

    Science.gov (United States)

    1979-12-01

    Gradients 48 16/19 3.17 Offset Towing Course 52 20 3.18 Straight and Level course 56 22 3.19 Suspension Courses 589a. Mrv 58 8 b. Boulder 59 8I c. Camera...Track 59 d. Setts 59 5/6t 3.20 Wading Pool 66 34 3.21 Field Dynamometer 68 39 3.22 Winch Test Facility 70 10 3.23 General Vehicle ( Dynamometer ) 73 4...PERCENT GRADE (1 IN 2) 18 TEST GRADIENT 33.3 PERCENT GRAD (1 IN 3) 19 TEST GRADIENT 25 PERCENT GRADE (I IN 4) 20 OFFSET TOWING SUSPENSION COURSE 21 OUTER

  2. The ESO Spectroscopic facility

    OpenAIRE

    Pasquini, Luca; Delabre, B.; Ellis, R. S.; Marrero, J.; L. Cavaller; de Zeeuw, Tim

    2017-01-01

    We present the concept of a novel facility dedicated to massively-multiplexed spectroscopy. The telescope has a very wide field Cassegrain focus optimised for fibre feeding. With a Field of View (FoV) of 2.5 degrees diameter and a 11.4m pupil, it will be the largest etendue telescope. The large focal plane can easily host up to 16.000 fibres. In addition, a gravity invariant focus for the central 10 arc-minutes is available to host a giant integral field unit (IFU). The 3 lenses corrector inc...

  3. CLIC Test Facility 3

    CERN Multimedia

    Kossyvakis, I; Faus-golfe, A; Nguyen, F

    2007-01-01

    The design of CLIC is based on a two-beam scheme, where short pulses of high power 30 GHz RF are extracted from a drive beam running parallel to the main beam. The 3rd generation CLIC Test Facility (CTF3) will demonstrate the generation of the drive beam with the appropriate time structure, the extraction of 30 GHz RF power from this beam, as well as acceleration of a probe beam with 30 GHz RF cavities. The project makes maximum use of existing equipment and infrastructure of the LPI complex, which became available after the closure of LEP.

  4. Technical Merits and Leadership in Facility Management

    National Research Council Canada - National Science Library

    Shoemaker, Jerry

    1997-01-01

    .... The document is divided into six chapters; the introduction, facility management and leadership, building systems, facility operations, facility maintenance strategies, and the conclusion and final analysis...

  5. Chimerical conditionals

    Directory of Open Access Journals (Sweden)

    Itamar Francez

    2015-01-01

    Full Text Available This paper introduces and analyzes chimerical conditionals, a class of conditionals that are puzzling vis-à-vis the distinction between so-called 'biscuit' and hypothetical conditionals. An analysis of this distinction is developed which draws on the pragmatic account of Franke 2009. Building on this analysis, chimericity is then shown to derive from a systematic ambiguity of a definite and often implicit argument in the consequent of chimerical conditionals, between a rigid designator and an individual concept reading. This ambiguity is argued to arise from different ways in which context can resolve familiarity presuppositions. One consequence of the inquiry is that the notion of (independence employed in much work on conditionals cannot be viewed as a relation between propositions, but must be made sensitive to the dynamics of information flow. http://dx.doi.org/10.3765/sp.8.2 BibTeX info

  6. Technical Safety Requirements for the Waste Storage Facilities May 2014

    Energy Technology Data Exchange (ETDEWEB)

    Laycak, D. T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-04-16

    This document contains the Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 625 (A625) and the Building 693 (B693) Yard Area of the Decontamination and Waste Treatment Facility (DWTF) at LLNL. The TSRs constitute requirements for safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the Documented Safety Analyses for the Waste Storage Facilities (DSA) (LLNL 2011). The analysis presented therein concluded that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts of waste from other DOE facilities, as described in the DSA. In addition, several minor treatments (e.g., size reduction and decontamination) are carried out in these facilities.

  7. Underground Facilities, Technological Challenges

    CERN Document Server

    Spooner, N

    2010-01-01

    This report gives a summary overview of the status of international under- ground facilities, in particular as relevant to long-baseline neutrino physics and neutrino astrophysics. The emphasis is on the technical feasibility aspects of creating the large underground infrastructures that will be needed in the fu- ture to house the necessary detectors of 100 kton to 1000 kton scale. There is great potential in Europe to build such a facility, both from the technical point of view and because Europe has a large concentration of the necessary engi- neering and geophysics expertise. The new LAGUNA collaboration has made rapid progress in determining the feasibility for a European site for such a large detector. It is becoming clear in fact that several locations are technically fea- sible in Europe. Combining this with the possibility of a new neutrino beam from CERN suggests a great opportunity for Europe to become the leading centre of neutrino studies, combining both neutrino astrophysics and neutrino beam stu...

  8. SPHERES National Lab Facility

    Science.gov (United States)

    Benavides, Jose

    2014-01-01

    SPHERES is a facility of the ISS National Laboratory with three IVA nano-satellites designed and delivered by MIT to research estimation, control, and autonomy algorithms. Since Fall 2010, The SPHERES system is now operationally supported and managed by NASA Ames Research Center (ARC). A SPHERES Program Office was established and is located at NASA Ames Research Center. The SPHERES Program Office coordinates all SPHERES related research and STEM activities on-board the International Space Station (ISS), as well as, current and future payload development. By working aboard ISS under crew supervision, it provides a risk tolerant Test-bed Environment for Distributed Satellite Free-flying Control Algorithms. If anything goes wrong, reset and try again! NASA has made the capability available to other U.S. government agencies, schools, commercial companies and students to expand the pool of ideas for how to test and use these bowling ball-sized droids. For many of the researchers, SPHERES offers the only opportunity to do affordable on-orbit characterization of their technology in the microgravity environment. Future utilization of SPHERES as a facility will grow its capabilities as a platform for science, technology development, and education.

  9. Geothermal energy conversion facility

    Energy Technology Data Exchange (ETDEWEB)

    Kutscher, C.F.

    1997-12-31

    With the termination of favorable electricity generation pricing policies, the geothermal industry is exploring ways to improve the efficiency of existing plants and make them more cost-competitive with natural gas. The Geothermal Energy Conversion Facility (GECF) at NREL will allow researchers to study various means for increasing the thermodynamic efficiency of binary cycle geothermal plants. This work has received considerable support from the US geothermal industry and will be done in collaboration with industry members and utilities. The GECF is being constructed on NREL property at the top of South Table Mountain in Golden, Colorado. As shown in Figure 1, it consists of an electrically heated hot water loop that provides heating to a heater/vaporizer in which the working fluid vaporizes at supercritical or subcritical pressures as high as 700 psia. Both an air-cooled and water-cooled condenser will be available for condensing the working fluid. In order to minimize construction costs, available equipment from the similar INEL Heat Cycle Research Facility is being utilized.

  10. The LLNL AMS facility

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, M.L.; Bench, G.S.; Brown, T.A. [Lawrence Livermore National Lab., CA (United States). Center for Accelerator Mass Spectrometry] [and others

    1996-05-01

    The AMS facility at Lawrence Livermore National Laboratory (LLNL) routinely measures the isotopes {sup 3}H, {sup 7}Be, {sup 10}Be, {sup 14}C, {sup 26}Al, {sup 36}Cl, {sup 41}Ca, {sup 59,63}Ni, and {sup 129}I. During the past two years, over 30,000 research samples have been measured. Of these samples, approximately 30% were for {sup 14}C bioscience tracer studies, 45% were {sup 14}C samples for archaeology and the geosciences, and the other isotopes constitute the remaining 25%. During the past two years at LLNL, a significant amount of work has gone into the development of the Projectile X-ray AMS (PXAMS) technique. PXAMS uses induced characteristic x-rays to discriminate against competing atomic isobars. PXAMS has been most fully developed for {sup 63}Ni but shows promise for the measurement of several other long lived isotopes. During the past year LLNL has also conducted an {sup 129}I interlaboratory comparison exercise. Recent hardware changes at the LLNL AMS facility include the installation and testing of a new thermal emission ion source, a new multianode gas ionization detector for general AMS use, re-alignment of the vacuum tank of the first of the two magnets that make up the high energy spectrometer, and a new cryo-vacuum system for the AMS ion source. In addition, they have begun design studies and carried out tests for a new high-resolution injector and a new beamline for heavy element AMS.

  11. The emergence of care facilities in Thailand for older German-speaking people: structural backgrounds and facility operators as transnational actors.

    Science.gov (United States)

    Bender, Désirée; Hollstein, Tina; Schweppe, Cornelia

    2017-12-01

    This paper presents findings from an ethnographic study of old age care facilities for German-speaking people in Thailand. It analyses the conditions and processes behind the development and specific designs of such facilities. It first looks at the intertwinement, at the socio-structural level, of different transborder developments in which the facilities' emergence is embedded. Second, it analyses the processes that accompany the emergence, development and organisation of these facilities at the local level. In this regard, it points out the central role of the facility operators as transnational actors who mediate between different frames of reference and groups of actors involved in these facilities. It concludes that the processes of mediation and intertwining are an important and distinctive feature of the emergence of these facilities, necessitated by the fact that, although the facilities are located in Thailand, their 'markets' are in the German-speaking countries of their target groups.

  12. Prizes awarded in fiscal 1999 by the Minister for International Trade and Industry on factories having applied excellent energy management. Energy conservation by installing fuel cell power generation facilities utilizing methane gas generated from waste water treatment plants / Improvements toward a clean room and energy saving air conditioning system; 1999 nendo energy kanri yuryo kojo tsusho sangyo daijin hyosho jusho. 1999 nendo shigen energy sho chokan hyosho jusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-04-01

    In order to achieve energy conservation in a waste water treatment plant in a brewery factories, an anaerobic treatment facility was introduced, and a fuel cell power generation facility effectively utilizing methane gas generated from the anaerobic waste water treatment plant was installed. This has resulted in large reduction in the operating number of blowers in the waste water treatment facility of activated sludge system. In addition, electric power, steam, and hot water generated from the fuel cells are effectively utilized as the factory utility. In energy conservation in an optical communication device manufacturing factory, the fan filter unit system was adopted, having been changed from the circulation air conditioner, a conventional type air conditioning system. The present system is a circulation system integrating the fan with the filter, making it possible to circulate air in the room to perform control of temperature, humidity, and dust in a clean room. Thus, the system has eliminated the circulating air conditioner, and reduced the air conditioner capacity by 42% and power consumption by 58.6% compared with those in the conventional circulation system. (NEDO)

  13. Liquid Effluent Retention Facility/Effluent Treatment Facility Hazards Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Simiele, G.A.

    1994-09-29

    This document establishes the technical basis in support of Emergency Planning activities for the Liquid Effluent Retention Facility and Effluent Treatment Facility the Hanford Site. The document represents an acceptable interpretation of the implementing guidance document for DOE ORDER 5500.3A. Through this document, the technical basis for the development of facility specific Emergency Action Levels and the Emergency Planning Zone is demonstrated.

  14. Indoor Lighting Facilities

    Science.gov (United States)

    Matsushima, Koji; Saito, Yoshinori; Ichikawa, Shigenori; Kawauchi, Takao; Tanaka, Tsuneo; Hirano, Rika; Tazuke, Fuyuki

    According to the statistics on building construction floor area from the Ministry of Land, Infrastructure, Transport and Tourism, the total floor area of building construction started in Japan in 2007 was 160,991 thousand square meters, or 14.8% less than the area of the previous year, and the reduction was the first reduction in the past five years. The office markets in Tokyo and Nagoya were active, as represented by the supplies of skyscrapers, and energy saving measures, such as the adoption of high efficiency lighting equipment, the control for initial stage illuminance, daylight harvesting, and the use of occupancy sensors, were well established. In the field of public construction, including museums, multi-purpose halls, and religious buildings, the total area of the new construction was 10.8% less than the total for the previous year, and this reduction was a continuation of an eleven-year trend. In spaces with high ceiling, the innovation for easy replacement of light sources used with reflection mirror systems and optical fibers was noted. Hospitals adapted to the expectation for improved services in their selection of lighting facilities to improve the residential environment for patients while taking into consideration the needs of the aging population, by their use of devices in corridors to help maintain a continuity of light. In libraries, a pendant system was developed to illuminate both ceilings and book shelves. In the field of theaters and halls, the time limit for repairing existing systems had come for the large facilities that were opened during the theater and hall construction boom of the 1960s through 1980s, and around 26 renovations were done. Almost all the renovations were conversions to intelligent dimming systems and lighting control desks. In the field of stores and commercial facilities, the atmosphere and glitter of the selling floor was produced by new light sources, such as ceramic metal halide lamps and LEDs, which have high

  15. Preliminary Design of the AEGIS Test Facility

    CERN Document Server

    Dassa, Luca; Cambiaghi, Danilo

    2010-01-01

    The AEGIS experiment is expected to be installed at the CERN Antiproton Decelerator in a very close future, since the main goal of the AEGIS experiment is the measurement of gravity impact on antihydrogen, which will be produced on the purpose. Antihydrogen production implies very challenging environmental conditions: at the heart of the AEGIS facility 50 mK temperature, 1e-12 mbar pressure and a 1 T magnetic field are required. Interfacing extreme cryogenics with ultra high vacuum will affect very strongly the design of the whole facility, requiring a very careful mechanical design. This paper presents an overview of the actual design of the AEGIS experimental facility, paying special care to mechanical aspects. Each subsystem of the facility – ranging from the positron source to the recombination region and the measurement region – will be shortly described. The ultra cold region, which is the most critical with respect to the antihydrogen formation, will be dealt in detail. The assembly procedures will...

  16. Environmental assessment: South microwave communication facilities

    Energy Technology Data Exchange (ETDEWEB)

    1989-06-01

    Western Area Power Administration (Western) is proposing to construct, operate, and maintain eight microwave repeater stations in southwestern Colorado, southeastern Utah, and northern Arizona, in order to meet the minimum fade criteria established by the Western Systems Coordinating Council (WSCC) for the operation and protection of electric power systems. The proposed microwave facilities would increase the reliability of communication. This environmental assessment (EA) describes the existing environmental conditions and the impacts from construction of the eight microwave communication facilities. The EA was prepared in compliance with the National Environmental Policy Act of 1969, the Council on Environmental Quality Regulations (40 CFR 1500-1508), and the Department of Energy Guidelines (52 FR 47662, December 15, 1987). The proposed project would consist of constructing eight microwave facilities, each of which would include a self-supported lattice tower, an equipment building, a propane tank, distribution lines to provide electric power to the sites, and access roads to the sites. The facilities would be constructed in San Miguel and Montezuma Counties in Colorado, San Juan County, Utah, and Navajo, Apache, Coconino, and Yavapai Counties in Arizona. 20 refs., 2 figs., 2 tabs.

  17. Power Systems Development Facility

    Energy Technology Data Exchange (ETDEWEB)

    Southern Company Services

    2009-01-31

    In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF), located in Wilsonville, Alabama, has routinely demonstrated gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a Transport Gasifier, a hot gas particulate control device, advanced syngas cleanup systems, and high-pressure solids handling systems. This final report summarizes the results of the technology development work conducted at the PSDF through January 31, 2009. Twenty-one major gasification test campaigns were completed, for a total of more than 11,000 hours of gasification operation. This operational experience has led to significant advancements in gasification technologies.

  18. Regulatory facility guide for Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, S.S.; Bock, R.E.; Francis, M.W.; Gove, R.M.; Johnson, P.E.; Kovac, F.M.; Mynatt, J.O. [Oak Ridge National Lab., TN (United States); Rymer, A.C. [Transportation Consulting Services, Knoxville, TN (United States)

    1994-02-28

    The Regulatory Facility Guide (RFG) has been developed for the DOE and contractor facilities located in the state of Ohio. It provides detailed compilations of international, federal, and state transportation-related regulations applicable to shipments originating at destined to Ohio facilities. This RFG was developed as an additional resource tool for use both by traffic managers who must ensure that transportation operations are in full compliance with all applicable regulatory requirements and by oversight personnel who must verify compliance activities.

  19. Construction and commissioning test report of the CEDM test facility

    Energy Technology Data Exchange (ETDEWEB)

    Chung, C. H.; Kim, J. T.; Park, W. M.; Youn, Y. J.; Jun, H. G.; Choi, N. H.; Park, J. K.; Song, C. H.; Lee, S. H.; Park, J. K

    2001-02-01

    The test facility for performance verification of the control element drive mechanism (CEDM) of next generation power plant was installed at the site of KAERI. The CEDM was featured a mechanism consisting of complicated mechanical parts and electromagnetic control system. Thus, a new CEDM design should go through performance verification tests prior to it's application in a reactor. The test facility can simulate the reactor operating conditions such as temperature, pressure and water quality and is equipped with a test chamber to accomodate a CEDM as installed in the power plant. This test facility can be used for the following tests; endurance test, coil cooling test, power measurement and reactivity rod drop test. The commissioning tests for the test facility were performed up to the CEDM test conditions of 320 C and 150 bar, and required water chemistry was obtained by operating the on-line water treatment system.

  20. Los Alamos National Laboratory corregated metal pipe saw facility preliminary safety analysis report. Volume I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-09-19

    This Preliminary Safety Analysis Report addresses site assessment, facility design and construction, and design operation of the processing systems in the Corrugated Metal Pipe Saw Facility with respect to normal and abnormal conditions. Potential hazards are identified, credible accidents relative to the operation of the facility and the process systems are analyzed, and the consequences of postulated accidents are presented. The risk associated with normal operations, abnormal operations, and natural phenomena are analyzed. The accident analysis presented shows that the impact of the facility will be acceptable for all foreseeable normal and abnormal conditions of operation. Specifically, under normal conditions the facility will have impacts within the limits posted by applicable DOE guidelines, and in accident conditions the facility will similarly meet or exceed the requirements of all applicable standards. 16 figs., 6 tabs.

  1. Materials Engineering Research Facility (MERF)

    Data.gov (United States)

    Federal Laboratory Consortium — Argonne?s Materials Engineering Research Facility (MERF) enables engineers to develop manufacturing processes for producing advanced battery materials in sufficient...

  2. Electronic Combat Integrated Test Facilities

    National Research Council Canada - National Science Library

    1992-01-01

    ... and evaluating weapons systems hardware and software in a controlled ground test environment. These facilities consist of anechoic chambers connected to various simulation and instrumentation laboratories...

  3. Agency Data on User Facilities

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of the Aerospace Technical Facility Inventory is to facilitate the sharing of specialized capabilities within the aerospace research/engineering...

  4. Low background infrared (LBIR) facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Low background infrared (LBIR) facility was originally designed to calibrate user supplied blackbody sources and to characterize low-background IR detectors and...

  5. Weapons Neutron Research Facility (WNR)

    Data.gov (United States)

    Federal Laboratory Consortium — The Weapons Neutron Research Facility (WNR) provides neutron and proton beams for basic, applied, and defense-related research. Neutron beams with energies ranging...

  6. Engine Environment Research Facility (EERF)

    Data.gov (United States)

    Federal Laboratory Consortium — Description: This facility supports research and development testing of the behavior of turbine engine lubricants, fuels and sensors in an actual engine environment....

  7. Poultry Slaughtering and Processing Facilities

    Data.gov (United States)

    Department of Homeland Security — Agriculture Production Poultry Slaughtering and Processing in the United States This dataset consists of facilities which engage in slaughtering, processing, and/or...

  8. Electronic Warfare Signature Measurement Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Electronic Warfare Signature Measurement Facility contains specialized mobile spectral, radiometric, and imaging measurement systems to characterize ultraviolet,...

  9. Service quality in contracted facilities.

    Science.gov (United States)

    Rabbani, Fauziah; Pradhan, Nousheen Akber; Zaidi, Shehla; Azam, Syed Iqbal; Yousuf, Farheen

    2015-01-01

    The purpose of this paper is to explore the readiness of contracted and non-contracted first-level healthcare facilities in Pakistan to deliver quality maternal and neonatal health (MNH) care. A balanced scorecard (BSC) was used as the assessment framework. Using a cross-sectional study design, two rural health centers (RHCs) contracted out to Aga Khan Health Service, Pakistan were compared with four government managed RHCs. A BSC was designed to assess RHC readiness to deliver good quality MNH care. In total 20 indicators were developed, representing five BSC domains: health facility functionality, service provision, staff capacity, staff and patient satisfaction. Validated data collection tools were used to collect information. Pearson χ2, Fisher's Exact and the Mann-Whitney tests were applied as appropriate to detect significant service quality differences among the two facilities. Contracted facilities were generally found to be better than non-contracted facilities in all five BSC domains. Patients' inclination for facility-based delivery at contracted facilities was, however, significantly higher than non-contracted facilities (80 percent contracted vs 43 percent non-contracted, p=0.006). The study shows that contracting out initiatives have the potential to improve MNH care. This is the first study to compare MNH service delivery quality across contracted and non-contracted facilities using BSC as the assessment framework.

  10. Radio Frequency Anechoic Chamber Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Supports the design, manufacture, and test of antenna systems. The facility is also used as an electromagnetic compatibility/radio frequency interference...

  11. National Ignition Facility system design requirements conventional facilities SDR001

    Energy Technology Data Exchange (ETDEWEB)

    Hands, J.

    1996-04-09

    This System Design Requirements (SDR) document specifies the functions to be performed and the minimum design requirements for the National Ignition Facility (NIF) site infrastructure and conventional facilities. These consist of the physical site and buildings necessary to house the laser, target chamber, target preparation areas, optics support and ancillary functions.

  12. Criticality Safety Evaluation of Hanford Tank Farms Facility

    Energy Technology Data Exchange (ETDEWEB)

    WEISS, E.V.

    2000-12-15

    Data and calculations from previous criticality safety evaluations and analyses were used to evaluate criticality safety for the entire Tank Farms facility to support the continued waste storage mission. This criticality safety evaluation concludes that a criticality accident at the Tank Farms facility is an incredible event due to the existing form (chemistry) and distribution (neutron absorbers) of tank waste. Limits and controls for receipt of waste from other facilities and maintenance of tank waste condition are set forth to maintain the margin subcriticality in tank waste.

  13. Characterization of the National Low-Temperature Neutron Irradiation Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kerchner, H.R.; Coltman, R.R. Jr.; Klabunde, C.E.; Young, F.W. Jr.

    1986-02-01

    The National Low-Temperature Neutron Irradiation Facility (NLTNIF) is now operating at the Bulk Shielding Reactor at ORNL. The facility provides high radiation intensities and special environmental and testing conditions for qualified experiments at no cost to users. A general description and major specifications of the NLTNIF are presented along with the results of performance tests. In addition, the hardware and other considerations required to perform experiments in the NLTNIF are described.

  14. Berhting Facilities Development Design for Makassar Main Naval VI Indonesian Navy

    OpenAIRE

    Rachman, Taufiqur

    2016-01-01

    In agenda of preparing Makassar Main Naval Base VI upgrading to be Middle Region Fleet Command and Military Sealift Command Position as homeport for KRI Ahmad Yani class frigate and KRI Makassar class LPD has berthing facilities llimited condition. Therefore, they propose a berthing facilities development program to Naval Headquarters to build a new facilities in Makassar. To get a maximum result from limited site with enviromental design condition, in designing lay out of development, an...

  15. Optimization of preventive health care facility locations

    Directory of Open Access Journals (Sweden)

    McGregor S

    2010-03-01

    Full Text Available Abstract Background Preventive health care programs can save lives and contribute to a better quality of life by diagnosing serious medical conditions early. The Preventive Health Care Facility Location (PHCFL problem is to identify optimal locations for preventive health care facilities so as to maximize participation. When identifying locations for preventive health care facilities, we need to consider the characteristics of the preventive health care services. First, people should have more flexibility to select service locations. Second, each preventive health care facility needs to have a minimum number of clients in order to retain accreditation. Results This paper presents a new methodology for solving the PHCFL problem. In order to capture the characteristics of preventive health care services, we define a new accessibility measurement that combines the two-step floating catchment area method, distance factor, and the Huff-based competitive model. We assume that the accessibility of preventive health care services is a major determinant for participation in the service. Based on the new accessibility measurement, the PHCFL problem is formalized as a bi-objective model based on efficiency and coverage. The bi-objective model is solved using the Interchange algorithm. In order to accelerate the solving process, we implement the Interchange algorithm by building two new data structures, which captures the spatial structure of the PHCFL problem. In addition, in order to measure the spatial barrier between clients and preventive health care facilities accurately and dynamically, this paper estimates travelling distance and travelling time by calling the Google Maps Application Programming Interface (API. Conclusions Experiments based on a real application for the Alberta breast cancer screening program show that our work can increase the accessibility of breast cancer screening services in the province.

  16. Optimization of preventive health care facility locations.

    Science.gov (United States)

    Gu, Wei; Wang, Xin; McGregor, S Elizabeth

    2010-03-18

    Preventive health care programs can save lives and contribute to a better quality of life by diagnosing serious medical conditions early. The Preventive Health Care Facility Location (PHCFL) problem is to identify optimal locations for preventive health care facilities so as to maximize participation. When identifying locations for preventive health care facilities, we need to consider the characteristics of the preventive health care services. First, people should have more flexibility to select service locations. Second, each preventive health care facility needs to have a minimum number of clients in order to retain accreditation. This paper presents a new methodology for solving the PHCFL problem. In order to capture the characteristics of preventive health care services, we define a new accessibility measurement that combines the two-step floating catchment area method, distance factor, and the Huff-based competitive model. We assume that the accessibility of preventive health care services is a major determinant for participation in the service. Based on the new accessibility measurement, the PHCFL problem is formalized as a bi-objective model based on efficiency and coverage. The bi-objective model is solved using the Interchange algorithm. In order to accelerate the solving process, we implement the Interchange algorithm by building two new data structures, which captures the spatial structure of the PHCFL problem. In addition, in order to measure the spatial barrier between clients and preventive health care facilities accurately and dynamically, this paper estimates travelling distance and travelling time by calling the Google Maps Application Programming Interface (API). Experiments based on a real application for the Alberta breast cancer screening program show that our work can increase the accessibility of breast cancer screening services in the province.

  17. Low-power arcjet test facility impacts

    Science.gov (United States)

    Morren, W. E.; Lichon, Paul J.

    1992-01-01

    Performance characterizations of a flight-type 1.4 kW arcjet system were conducted. Performance and thruster temperature distributions were measured at thruster input power levels and propellant mass flow rates ranging from 1274 to 1370 W and from 3.2 x 10 exp -5 to 5.1 x 10 exp -5 kg/s, respectively. Specific impulses measured at the two facilities, at comparable test cell pressures, using gaseous hydrogen-nitrogen propellant mixtures agreed to within 1 percent over the range of operating conditions tested. The specific impulses measured using hydrazine propellant were higher than that for the cold hydrogen/nitrogen mixtures. Agreement between the hydrazine and gas mixture data was good, however, when the differences in propellant ethalpies at the thruster inlet were considered. Specific impulse showed a strong dependence on test facility pressure, and was 3 to 4 percent higher below 0.1 Pa than for test cell pressures above 5 Pa.

  18. Renovating animal facilities to withstand disasters.

    Science.gov (United States)

    Cartwright, Jim; Contratto, Jim; Gould, Nathan; Freeman, William

    2013-10-01

    In the aftermath of Superstorm Sandy, new attention has been drawn to planning for and mitigating the effects of disasters on laboratory animal facilities. A number of design approaches and solutions can be easily incorporated into a new vivarium, enhancing its ability to withstand and recover from a disaster. Renovating a vivarium poses special challenges, however. Existing conditions in the project area may dictate which approaches or solutions are feasible, and retrofitting is often more complex and expensive than incorporating the same features into new construction. The authors explain how project design teams can evaluate the types of disasters that a renovated facility will need to address and develop a design strategy that responds to these disasters in the most effective way.

  19. Related Conditions

    Science.gov (United States)

    ... diseases; starting first with eczema, then followed by food allergy, asthma, and allergic rhinitis. Researchers don’t yet know whether the Atopic March conditions merely coexist in people with overactive immune systems, or ... with eczema and food allergy in early childhood. However, the diseases don’ ...

  20. 78 FR 78402 - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving...

    Science.gov (United States)

    2013-12-26

    ... Analysis Report (UFSAR), nor does it adversely alter design assumptions, conditions, or configurations of... initiators nor alter design assumptions, or conditions of the facility. The proposed amendment does not... COMMISSION Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving...

  1. Power Systems Development Facility

    Energy Technology Data Exchange (ETDEWEB)

    None

    2003-07-01

    This report discusses Test Campaign TC12 of the Kellogg Brown & Root, Inc. (KBR) Transport Gasifier train with a Siemens Westinghouse Power Corporation (SW) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Gasifier is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using a particulate control device (PCD). While operating as a gasifier, either air or oxygen can be used as the oxidant. Test run TC12 began on May 16, 2003, with the startup of the main air compressor and the lighting of the gasifier start-up burner. The Transport Gasifier operated until May 24, 2003, when a scheduled outage occurred to allow maintenance crews to install the fuel cell test unit and modify the gas clean-up system. On June 18, 2003, the test run resumed when operations relit the start-up burner, and testing continued until the scheduled end of the run on July 14, 2003. TC12 had a total of 733 hours using Powder River Basin (PRB) subbituminous coal. Over the course of the entire test run, gasifier temperatures varied between 1,675 and 1,850 F at pressures from 130 to 210 psig.

  2. Simulation Facilities and Test Beds for Galileo

    Science.gov (United States)

    Schlarmann, Bernhard Kl.; Leonard, Arian

    2002-01-01

    Galileo is the European satellite navigation system, financed by the European Space Agency (ESA) and the European Commission (EC). The Galileo System, currently under definition phase, will offer seamless global coverage, providing state-of-the-art positioning and timing services. Galileo services will include a standard service targeted at mass market users, an augmented integrity service, providing integrity warnings when fault occur and Public Regulated Services (ensuring a continuity of service for the public users). Other services are under consideration (SAR and integrated communications). Galileo will be interoperable with GPS, and will be complemented by local elements that will enhance the services for specific local users. In the frame of the Galileo definition phase, several system design and simulation facilities and test beds have been defined and developed for the coming phases of the project, respectively they are currently under development. These are mainly the following tools: Galileo Mission Analysis Simulator to design the Space Segment, especially to support constellation design, deployment and replacement. Galileo Service Volume Simulator to analyse the global performance requirements based on a coverage analysis for different service levels and degrades modes. Galileo System Simulation Facility is a sophisticated end-to-end simulation tool to assess the navigation performances for a complete variety of users under different operating conditions and different modes. Galileo Signal Validation Facility to evaluate signal and message structures for Galileo. Galileo System Test Bed (Version 1) to assess and refine the Orbit Determination &Time Synchronisation and Integrity algorithms, through experiments relying on GPS space infrastructure. This paper presents an overview on the so called "G-Facilities" and describes the use of the different system design tools during the project life cycle in order to design the system with respect to

  3. Thomas Jefferson National Accelerator Facility

    Energy Technology Data Exchange (ETDEWEB)

    Grames, Joseph; Higinbotham, Douglas; Montgomery, Hugh

    2010-09-08

    The Thomas Jefferson National Accelerator Facility (Jefferson Lab) in Newport News, Virginia, USA, is one of ten national laboratories under the aegis of the Office of Science of the U.S. Department of Energy (DOE). It is managed and operated by Jefferson Science Associates, LLC. The primary facility at Jefferson Lab is the Continuous Electron Beam Accelerator Facility (CEBAF) as shown in an aerial photograph in Figure 1. Jefferson Lab was created in 1984 as CEBAF and started operations for physics in 1995. The accelerator uses superconducting radio-frequency (srf) techniques to generate high-quality beams of electrons with high-intensity, well-controlled polarization. The technology has enabled ancillary facilities to be created. The CEBAF facility is used by an international user community of more than 1200 physicists for a program of exploration and study of nuclear, hadronic matter, the strong interaction and quantum chromodynamics. Additionally, the exceptional quality of the beams facilitates studies of the fundamental symmetries of nature, which complement those of atomic physics on the one hand and of high-energy particle physics on the other. The facility is in the midst of a project to double the energy of the facility and to enhance and expand its experimental facilities. Studies are also pursued with a Free-Electron Laser produced by an energy-recovering linear accelerator.

  4. Accreditation for Indoor Climbing Facilities.

    Science.gov (United States)

    Mayfield, Peter

    To ensure that the rapidly growing climbing gym industry maintains the excellent safety record established so far, the Climbing Gym Association (CGA) has developed the Peer Review and Accreditation Program, a process of review between qualified and experienced CGA reviewers and a climbing facility operator to assess the facility's risk management…

  5. Designing Facilities for Collaborative Operations

    Science.gov (United States)

    Norris, Jeffrey; Powell, Mark; Backes, Paul; Steinke, Robert; Tso, Kam; Wales, Roxana

    2003-01-01

    A methodology for designing operational facilities for collaboration by multiple experts has begun to take shape as an outgrowth of a project to design such facilities for scientific operations of the planned 2003 Mars Exploration Rover (MER) mission. The methodology could also be applicable to the design of military "situation rooms" and other facilities for terrestrial missions. It was recognized in this project that modern mission operations depend heavily upon the collaborative use of computers. It was further recognized that tests have shown that layout of a facility exerts a dramatic effect on the efficiency and endurance of the operations staff. The facility designs (for example, see figure) and the methodology developed during the project reflect this recognition. One element of the methodology is a metric, called effective capacity, that was created for use in evaluating proposed MER operational facilities and may also be useful for evaluating other collaboration spaces, including meeting rooms and military situation rooms. The effective capacity of a facility is defined as the number of people in the facility who can be meaningfully engaged in its operations. A person is considered to be meaningfully engaged if the person can (1) see, hear, and communicate with everyone else present; (2) see the material under discussion (typically data on a piece of paper, computer monitor, or projection screen); and (3) provide input to the product under development by the group. The effective capacity of a facility is less than the number of people that can physically fit in the facility. For example, a typical office that contains a desktop computer has an effective capacity of .4, while a small conference room that contains a projection screen has an effective capacity of around 10. Little or no benefit would be derived from allowing the number of persons in an operational facility to exceed its effective capacity: At best, the operations staff would be underutilized

  6. Facility effluent monitoring plan for the 325 Facility

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    The Applied Chemistry Laboratory (325 Facility) houses radiochemistry research, radioanalytical service, radiochemical process development, and hazardous and mixed hazardous waste treatment activities. The laboratories and specialized facilities enable work ranging from that with nonradioactive materials to work with picogram to kilogram quantities of fissionable materials and up to megacurie quantities of other radionuclides. The special facilities include two shielded hot-cell areas that provide for process development or analytical chemistry work with highly radioactive materials, and a waste treatment facility for processing hazardous, mixed, low-level, and transuranic wastes generated by Pacific Northwest Laboratory. Radioactive material storage and usage occur throughout the facility and include a large number of isotopes. This material is in several forms, including solid, liquid, particulate, and gas. Some of these materials are also heated during testing which can produce vapors. The research activities have been assigned to the following activity designations: High-Level Hot Cell, Hazardous Waste Treatment Unit, Waste Form Development, Special Testing Projects, Chemical Process Development, Analytical Hot Cell, and Analytical Chemistry. The following summarizes the airborne and liquid effluents and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterization of effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements.

  7. Gas cooled fast breeder reactor design for a circulator test facility (modified HTGR circulator test facility)

    Energy Technology Data Exchange (ETDEWEB)

    1979-10-01

    A GCFR helium circulator test facility sized for full design conditions is proposed for meeting the above requirements. The circulator will be mounted in a large vessel containing high pressure helium which will permit testing at the same power, speed, pressure, temperature and flow conditions intended in the demonstration plant. The electric drive motor for the circulator will obtain its power from an electric supply and distribution system in which electric power will be taken from a local utility. The conceptual design decribed in this report is the result of close interaction between the General Atomic Company (GA), designer of the GCFR, and The Ralph M. Parson Company, architect/engineer for the test facility. A realistic estimate of total project cost is presented, together with a schedule for design, procurement, construction, and inspection.

  8. Hanford Site Near-Facility Environmental Monitoring Data Report for Calendar Year 2008

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, Craig J.; Dorsey, Michael C.; Mckinney, Stephen M.; Wilde, Justin W.; Poston, Ted M.

    2009-09-15

    Near-facility environmental monitoring is defined as monitoring near facilities that have the potential to discharge or have discharged, stored, or disposed of radioactive or hazardous materials. Monitoring locations are associated with nuclear facilities such as the Plutonium Finishing Plant, Canister Storage Building, and the K Basins; inactive nuclear facilities such as N Reactor and the Plutonium-Uranium Extraction (PUREX) Facility; and waste storage or disposal facilities such as burial grounds, cribs, ditches, ponds, tank farms, and trenches. Much of the monitoring consists of collecting and analyzing environmental samples and methodically surveying areas near facilities. The program is also designed to evaluate acquired analytical data, determine the effectiveness of facility effluent monitoring and controls, assess the adequacy of containment at waste disposal units, and detect and monitor unusual conditions.

  9. 42 CFR 494.180 - Condition: Governance.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Governance. 494.180 Section 494.180... Administration § 494.180 Condition: Governance. The ESRD facility is under the control of an identifiable governing body, or designated person(s) with full legal authority and responsibility for the governance and...

  10. Facility effluent monitoring plan for the plutonium uranium extraction facility

    Energy Technology Data Exchange (ETDEWEB)

    Wiegand, D.L.

    1994-09-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years.

  11. 33 CFR 154.1216 - Facility classification.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Facility classification. 154.1216... Vegetable Oils Facilities § 154.1216 Facility classification. (a) The Coast Guard classifies facilities that... classification of a facility that handles, stores, or transports animal fats or vegetable oils. The COTP may...

  12. Technical merits and leadership in facility management

    OpenAIRE

    Shoemaker, Jerry J

    1997-01-01

    After almost ten years of experience and formal education in design, construction, and facility operations and maintenance, the challenges and complexity of facility management still seem overwhelming and intangible. This document explores those complexities and challenges, and presents several philosophies and strategies practiced in facility management. The document is divided into six chapters; the introduction, facility management and leadership, building systems, facility operations, fac...

  13. Window Observational Research Facility (WORF)

    Science.gov (United States)

    Pelfrey, Joseph; Sledd, Annette

    2007-01-01

    This viewgraph document concerns the Window Observational Research Facility (WORF) Rack, a unique facility designed for use with the US Lab Destiny Module window. WORF will provide valuable resources for Earth Science payloads along with serving the purpose of protecting the lab window. The facility can be used for remote sensing instrumentation test and validation in a shirt sleeve environment. WORF will also provide a training platform for crewmembers to do orbital observations of other planetary bodies. WORF payloads will be able to conduct terrestrial studies utilizing the data collected from utilizing WORF and the lab window.

  14. Design Integration of Facilities Management

    DEFF Research Database (Denmark)

    Jensen, Per Anker

    2009-01-01

    One of the problems in the building industry is a limited degree of learning from experiences of use and operation of existing buildings. Development of professional facilities management (FM) can be seen as the missing link to bridge the gap between building operation and building design....... Involvement of professional facilities managers in the design process is an obvious strategy, but increased competences are needed among building clients, designers and the operational staff. More codification of operational knowledge is also needed, for instance in IT systems. The paper is based...... of considerations for facilities management....

  15. TREAT neutron-radiography facility

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, L.J.

    1981-01-01

    The TREAT reactor was built as a transient irradiation test reactor. By taking advantage of built-in system features, it was possible to add a neutron-radiography facility. This facility has been used over the years to radiograph a wide variety and large number of preirradiated fuel pins in many different configurations. Eight different specimen handling casks weighing up to 54.4 t (60 T) can be accommodated. Thermal, epithermal, and track-etch radiographs have been taken. Neutron-radiography service can be provided for specimens from other reactor facilities, and the capacity for storing preirradiated specimens also exists.

  16. PLANS FOR FUTURE MEGAWATT FACILITIES.

    Energy Technology Data Exchange (ETDEWEB)

    ROSER,T.

    2004-10-13

    Proton accelerators producing beam powers of up to 1 MW are presently either operating or under construction and designs for Multi-Megawatt facilities are being developed. High beam power has applications in the production of high intensity secondary beams of neutrons, muons, kaons and neutrinos as well as in nuclear waste transmutation and accelerator-driven sub-critical reactors. Each of these applications has additional requirements on beam energy and duty cycle. This paper will review how present designs for future Multi-Megawatt facilities meet these requirements and will also review the experience with present high power facilities.

  17. Low power arcjet test facility impacts

    Science.gov (United States)

    Morren, W. Earl; Lichon, Paul J.

    1992-01-01

    Performance characterization of a flight-type 1.4 kW arcjet system were conducted at the Rocket Research Company (RRC) in Redmond, WA, and at the NASA LeRC in Cleveland, OH. The objectives of these tests were as follows: to compare low-power arcjet performance at two different test facilities; to compare arcjet performance obtained with a 2:1 mixture of gaseous hydrogen and nitrogen and hydrazine; and to quantify the effects of test cell pressure on thruster operating characteristics. Performance and thruster temperature distributions were measured at thruster input power levels and propellant mass flow rates ranging from 1274 to 1370 W and from 3.2 x 10(exp -5) to 5.1 x 10(exp -5) kg/s, respectively. Specific impulses measured at the two facilities, at comparable test cell pressures, using gaseous hydrogen-nitrogen propellant mixtures agreed to within 1 percent over the range of operating conditions tested. The specific impulses measured using hydrazine propellant were higher than that for the cold hydrogen-nitrogen mixtures. Agreement between by hydrazine and gas mixture data was good, however, when the differences in propellant enthalpies at the thruster inlet were considered. Specific impulse showed a strong dependence on test facility pressure, and was 3 to 4 percent higher below 0.1 Pa than for test cell pressures above 5 Pa.

  18. Facility effluent monitoring plan for 242-A evaporator facility

    Energy Technology Data Exchange (ETDEWEB)

    Crummel, G.M.; Gustavson, R.D.

    1995-02-01

    A facility effluent monitoring plan is required by the U.S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation showed the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-1. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated, as a minimum, every three years.

  19. The Institute for Rock Magnetism Facility Database

    Science.gov (United States)

    Jackson, M. J.; Sølheid, P.; Bowles, J. A.; Moskowitz, B. M.; Feinberg, J. M.

    2012-12-01

    The Institute for Rock Magnetism (IRM) is one of 19 National Multi-User Facilities supported by the Instruments and Facilities program of NSF for geoscience research that requires complex, expensive and advanced instrumentation. Visiting and in-house researchers at the IRM have access to sensitive laboratory instruments for magnetometry, magnetic microscopy and Mössbauer spectroscopy, for carrying out a wide variety of experiments under a range of applied field and temperature conditions. Results are used to gain insight into a very diverse assortment of natural materials and phenomena including biomagnetism, environmental magnetism, petrofabrics, nanophase materials, shocked materials, and paleomagnetism of terrestrial and extraterrestrial materials. A comprehensive laboratory database has been in operation since 2004, storing detailed experimental data and metadata for more than 250 facility users, with measurements on over 50,000 specimens, including over one million remanence measurements and 45,000 hysteresis loops. Custom software tools provide consistent and reliable handling of basic data processing (e.g., mass normalization and unit conversion), as well as more advanced interactive analysis (e.g., deconvolution of u-channel paleomagnetic data; filtering and statistical tests for high-field nonlinearity in calculating hysteresis loop parameters; thermal fluctuation tomography using T-dependent switching-field distributions from backfield remanence measurements or hysteresis loops). Users are also able to access their data and the custom software tools remotely once they leave the IRM for their home institutions. A key advantage of an integrated database/software system for a facility like the IRM is that it provides a rapid and automatic means of combining different kinds of data measured on different instruments. An important design consideration in the development of the facility database has been structural compatibility with the community-wide Mag

  20. Hot conditioning equipment conceptual design report

    Energy Technology Data Exchange (ETDEWEB)

    Bradshaw, F.W., Westinghouse Hanford

    1996-08-06

    This report documents the conceptual design of the Hot Conditioning System Equipment. The Hot conditioning System will consist of two separate designs: the Hot Conditioning System Equipment; and the Hot Conditioning System Annex. The Hot Conditioning System Equipment Design includes the equipment such as ovens, vacuum pumps, inert gas delivery systems, etc.necessary to condition spent nuclear fuel currently in storage in the K Basins of the Hanford Site. The Hot Conditioning System Annex consists of the facility of house the Hot Conditioning System. The Hot Conditioning System will be housed in an annex to the Canister Storage Building. The Hot Conditioning System will consist of pits in the floor which contain ovens in which the spent nuclear will be conditioned prior to interim storage.

  1. Facilities for Development of Modified Nitride-Based Fuel Pellets

    Energy Technology Data Exchange (ETDEWEB)

    Meier, T; Ebbinghaus, B; Choi, J

    2003-10-22

    Facilities to support development of modified nitride-based reactor fuel pellets have been activated and are now in operation at Lawrence Livermore National Laboratory. These facilities provide the controls and monitored laboratory conditions required to produce, evaluate, and verify quality of the nitride-based product required for this fuel application. By preserving the high melting point, high thermal conductivity, and high actinide density properties of nitride fuel while enhancing stoichiometry, density, and grain structure, and by applying inert matrix (ZrN) and neutron absorbing (HfN) additives for improved stability and burn-up characteristics, the requirements for a long-life fuel to support sealed core reactor applications may be met. This paper discusses requirements for producing the modified nitride powders for sintering of fuel pellets, translation of these requirements into facility specifications, and implementation of these specifications as facility capabilities.

  2. Winning market positioning strategies for long term care facilities.

    Science.gov (United States)

    Higgins, L F; Weinstein, K; Arndt, K

    1997-01-01

    The decision to develop an aggressive marketing strategy for its long term care facility has become a priority for the management of a one-hundred bed facility in the Rocky Mountain West. Financial success and lasting competitiveness require that the facility in question (Deer Haven) establish itself as the preferred provider of long term care for its target market. By performing a marketing communications audit, Deer Haven evaluated its present market position and created a strategy for solidifying and dramatizing this position. After an overview of present conditions in the industry, we offer a seven step process that provides practical guidance for positioning a long term care facility. We conclude by providing an example application.

  3. Optimal location of a mine facility by genetic algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Kumral, M. [Inonu University, Malatya (Turkey). School of Engineering

    2004-06-01

    When raw material is extracted from multiple mines or faces and when the construction of a mine facility is being planned, the selection for the optimal location of the facility is an important consideration because of high transportation costs. This paper presents an approach for the selection of optimal location of a mining facility based on the genetic algorithms which is a directed random search technique. The technique, simple and easy to apply, is demonstrated for the case of the location of a coal washery plant, whose supply comes from five mines with varying reserves and coal qualities, topographical conditions and mine status. The result shows that the solution produced by the proposed algorithm can be used to find the optimal location of any mining facility.

  4. Experimental Fuels Facility Re-categorization Based on Facility Segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Reiss, Troy P.; Andrus, Jason

    2016-07-01

    The Experimental Fuels Facility (EFF) (MFC-794) at the Materials and Fuels Complex (MFC) located on the Idaho National Laboratory (INL) Site was originally constructed to provide controlled-access, indoor storage for radiological contaminated equipment. Use of the facility was expanded to provide a controlled environment for repairing contaminated equipment and characterizing, repackaging, and treating waste. The EFF facility is also used for research and development services, including fuel fabrication. EFF was originally categorized as a LTHC-3 radiological facility based on facility operations and facility radiological inventories. Newly planned program activities identified the need to receive quantities of fissionable materials in excess of the single parameter subcritical limit in ANSI/ANS-8.1, “Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors” (identified as “criticality list” quantities in DOE-STD-1027-92, “Hazard Categorization and Accident Analysis Techniques for Compliance with DOE Order 5480.23, Nuclear Safety Analysis Reports,” Attachment 1, Table A.1). Since the proposed inventory of fissionable materials inside EFF may be greater than the single parameter sub-critical limit of 700 g of U-235 equivalent, the initial re-categorization is Hazard Category (HC) 2 based upon a potential criticality hazard. This paper details the facility hazard categorization performed for the EFF. The categorization was necessary to determine (a) the need for further safety analysis in accordance with LWP-10802, “INL Facility Categorization,” and (b) compliance with 10 Code of Federal Regulations (CFR) 830, Subpart B, “Safety Basis Requirements.” Based on the segmentation argument presented in this paper, the final hazard categorization for the facility is LTHC-3. Department of Energy Idaho (DOE-ID) approval of the final hazard categorization determined by this hazard assessment document (HAD) was required per the

  5. Welding and Production Metallurgy Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This 6000 square foot facility represents the only welding laboratory of its kind within DA. It is capable of conducting investigations associated with solid state...

  6. Multi-Directional Experimental Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The ATLSS Multi-directional Experimental Laboratory was constructed in 1987 under funding from the National Science Foundation to be a major facility for large-scale...

  7. The radioactive beam facility ALTO

    Energy Technology Data Exchange (ETDEWEB)

    Essabaa, Saïd, E-mail: essabaa@ipno.in2p3.fr; Barré-Boscher, Nicole; Cheikh Mhamed, Maher; Cottereau, Evelyne; Franchoo, Serge; Ibrahim, Fadi; Lau, Christophe; Roussière, Brigitte; Saïd, Abdelhakim; Tusseau-Nenez, Sandrine; Verney, David

    2013-12-15

    Highlights: • Research at the ALTO TNA-facility. • R and D on radioactive ion sources. • R and D on the lanthanide beam production by fluorination. • Recent developments on uranium carbide targets. -- Abstract: The Transnational Access facility ALTO (TNA07-ENSAR/FP7) has been commissioned and received from the French safety authorities, the operation license. It is allowed to run at nominal intensity to produce 10{sup 11} fissions/s in a thick uranium carbide target by photo-fission using a 10 μA, 50 MeV electron beam. In addition the recent success in operating the selective laser ion source broadens the physics program with neutron-rich nuclear beams possible at this facility installed at IPN Orsay. The facility also aims at being a test bench for the SPIRAL2 project. In that framework an ambitious R and D program on the target ion source system is being developed.

  8. Hot Fuel Examination Facility (HFEF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Hot Fuel Examination Facility (HFEF) is one of the largest hot cells dedicated to radioactive materials research at Idaho National Laboratory (INL). The nation's...

  9. Reverse Ballistic Air Gun Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This custom-designed facility houses a suite of three air guns capable of generating accelerations up to 100,000 Gs and velocities up to 2,000 ft/s. In addition to a...

  10. Elevated Fixed Platform Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Elevated Fixed Platform (EFP) is a helicopter recovery test facility located at Lakehurst, NJ. It consists of a 60 by 85 foot steel and concrete deck built atop...

  11. Knowledge Map of Facilities Management

    DEFF Research Database (Denmark)

    Nenonen, Suvi; Jensen, Per Anker; Lindahl, Göran

    2014-01-01

    Purpose This paper aims to draft a knowledge map of the fragmented and multidisciplinary research of and relevant to FM. Facilities management knowledge map is a tool for presenting what relevant data and knowledge, a.k.a. knowledge, resides in different disciplines. Knowledge mapping is a step...... in creating an inventory of knowledge (i.e. the knowledge base) and developing/improving the processes of knowledge sharing in research, education and practice. Theory Knowledge mapping is discussed in terms of knowledge management. The research is connected to knowledge mapping in the facilities management...... profession, research and education. The knowledge map aims to contrast perspectives on how to map interdisciplinary research. Design/methodology/approach The Knowledge map is based on classification of 83 articles, including volume 2013 of Facilities (40 articles) and of Journal of Facilities Management (21...

  12. CLAIMS OF SUSTAINABLE FACILITIES MANAGEMENT

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev

    Purpose: The purpose of the paper is to provide an overview of current practices within the emergent management discipline: Sustainable Facilities Management (SFM). Background: To develop a sustainable society, facilities managers must become change agents for sustainability in the built...... environment. Facilities Management (FM) is contributing to the environmental, social and economical problems, but can at the same time also be a part of the solution. However, to integrate sustainability in FM is still an emergent niche within FM, and the examples of SFM so far seems to come out of very......-creating of new socio-technical services and technologies These SFM understandings are concluded to be coexisting claims of SFM definitions. Practical Implications: Facilities managers will be able to identify the mindset behind different services and technologies that are promoted as SFM. But maybe just...

  13. Nursing Facility Initiative Annual Report

    Data.gov (United States)

    U.S. Department of Health & Human Services — This annual report summarizes impacts from the Initiative to Reduce Avoidable Hospitalizations among Nursing Facility Residents in 2014. This initiative is designed...

  14. Ion Cyclotron Resonance Facility (ICR)

    Data.gov (United States)

    Federal Laboratory Consortium — his facility is charged with developing and exploiting the unique capabilities of Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry, and leads the...

  15. Reverberant Acoustic Test Facility (RATF)

    Data.gov (United States)

    Federal Laboratory Consortium — The very large Reverberant Acoustic Test Facility (RATF) at the NASA Glenn Research Center (GRC), Plum Brook Station, is currently under construction and is due to...

  16. Color and appearance metrology facility

    Data.gov (United States)

    Federal Laboratory Consortium — The NIST Physical Measurement Laboratory has established the color and appearance metrology facility to support calibration services for 0°/45° colored samples, 20°,...

  17. Design & layout of recreation facilities

    Science.gov (United States)

    Howard R. Orr

    1971-01-01

    Design and layout of recreation facilities is a problem solving process that must be divorced from the emotionalism that has shrouded outdoor recreation and must deal deliberately with the growing information concerning people and natural resources.

  18. Detonation Engine Research Facility (DERF)

    Data.gov (United States)

    Federal Laboratory Consortium — Description: This facility is configured to safely conduct experimental pressuregain combustion research. The DERF is capable of supporting up to 60,000 lbf thrust...

  19. Regulatory Facility Guide for Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, S.S.; Bock, R.E.; Francis, M.W.; Gove, R.M.; Johnson, P.E.; Kovac, F.M.; Mynatt, J.O. [Oak Ridge National Lab., TN (United States); Rymer, A.C. [Transportation Consulting Services, Knoxville, TN (United States)

    1994-02-28

    This guide provides detailed compilations of international, federal, and state transportation related regulations applicable to shipments originating at or destined to Tennessee facilities. Information on preferred routes is also given.

  20. Production Facility SCADA Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Holloway, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Baily, Scott A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wheat, Robert Mitchell Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-03-23

    The following report covers FY 14 activities to develop supervisory control and data acquisition (SCADA) system for the Northstar Moly99 production facility. The goal of this effort is to provide Northstar with a baseline system design.

  1. Region 7 Title V facilities

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web map shows the Region 7 Title V facilities (Clean Air Act major sources), any Class I areas within 300 km of R7 States, and any Tribal areas within 50 miles...

  2. Indonesia - Green Prosperity - Grant Facility

    Data.gov (United States)

    Millennium Challenge Corporation — The evaluation is designed to assess the design and operations of the GP Facility, which consists of Activities 2-3 of the GP Project. It is a performance evaluation...

  3. Freshwater Treatment and Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Freshwater Treatment and Test Facility, located at SANGB, has direct year-round access to water from Lake St. Clair and has a State of Michigan approved National...

  4. Aircraft Horizontal Thrust Measurement Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility is designed to support the DoD mission by providing unique air vehicle installed engine performance (thrust output) measurements. This system consists...

  5. Biomass Feedstock National User Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Bioenergy research at the Biomass Feedstock National User Facility (BFNUF) is focused on creating commodity-scale feed-stocks from native biomass that meet the needs...

  6. Critical Facilities for Coastal Geographies

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The critical facilities data are derived from the USGS Structures Inventory Database (June, 2016). The structures in the derived dataset displays aggregated totals...

  7. URAM-2 Cryogenic Irradiation Facility

    CERN Document Server

    Shabalin, E P; Kulikov, S A; Kulagin, E N; Melihov, V V; Belyakov, A A; Golovanov, L B; Borzunov, Yu T; Konstantinov, V I; Androsov, A V

    2002-01-01

    The URAM-2 irradiation facility has been built and mounted at the channel No. 3 of the IBR-2 reactor. It was constructed for study of radiolysis effects by fast neutron irradiation in some suitable for effective cold neutron production materials (namely: solid methane, methane hydrate, water ice, etc.). The facility cooling system is based on using liquid helium as a coolant material. The original charging block of the rig allows the samples to be loaded by condensing gas into irradiation cavity or by charging beads of ice prepared before. Preliminary tests for each facility block and assembling them at the working position were carried out. Use of the facility for study accumulation of chemical energy under irradiation at low temperature in materials mentioned above and its spontaneous release was started.

  8. Critical Facilities for Coastal Geographies

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The critical facilities data are derived from the USGS Structures Inventory Database (June, 2015). The structures in the derived dataset displays aggregated totals...

  9. Standoff Detection Technology Evaluation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Standoff Detection Technology Evaluation facility is the only one of its kind in the country and allows researchers to release a known amount of material while...

  10. Space Station Furnace Facility. Experiment/Facility Requirements Document (E/FRD), volume 2, appendix 5

    Science.gov (United States)

    Kephart, Nancy

    1992-01-01

    The function of the Space Station Furnace Facility (SSFF) is to support materials research into the crystal growth and solidification processes of electronic and photonic materials, metals and alloys, and glasses and ceramics. To support this broad base of research requirements, the SSFF will employ a variety of furnace modules operated, regulated, and supported by a core of common subsystems. Furnace modules may be reconfigured or specifically developed to provide unique solidifcation conditions for each set of experiments. The SSFF modular approach permits the addition of new or scaled-up furnace modules to support the evolution of the facility as new science requirements are identified. The SSFF Core is of modular design to permit augmentation for enhanced capabilities. The fully integrated configuration of the SSFF will consist of three racks with the capability of supporting up to two furnace modules per rack. The initial configuration of the SSFF will consist of two of the three racks and one furnace module. This Experiment/Facility Requirements Document (E/FRD) describes the integrated facility requirements for the Space Station Freedom (SSF) Integrated Configuration-1 (IC1) mission. The IC1 SSFF will consist of two racks: the Core Rack, with the centralized subsystem equipment, and the Experiment Rack-1, with Furnace Module-1 and the distributed subsystem equipment to support the furnace.

  11. Thermodynamic analysis of spent pyrochemical salts in the stored condition and in viable accident scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Axler, K.M.

    1994-03-01

    This study involves examining ``spent`` electrorefining (ER) salts in the form present after usage (as stored), and then after exposure to water in a proposed accident scenario. Additionally, the equilibrium composition of the salt after extended exposure to air was also calculated by computer modeling and those results are also presented herein. It should be noted that these salts are extremely similar to spent MSE salts from the Rocky Flats MSE campaigns using NaCl-KCl- MgCl{sub 2}.

  12. EPA Facility Registry Service (FRS): TRI

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  13. EPA Facility Registry Service (FRS): BIA

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  14. Aircraft Test & Evaluation Facility (Hush House)

    Data.gov (United States)

    Federal Laboratory Consortium — The Aircraft Test and Evaluation Facility (ATEF), or Hush House, is a noise-abated ground test sub-facility. The facility's controlled environment provides 24-hour...

  15. EPA Facility Registry Service (FRS): RADINFO

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  16. EPA Facility Registry Service (FRS): OIL

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Oil...

  17. EPA Facility Registry Service (FRS): RMP

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  18. EPA Facility Registry Service (FRS): SDWIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  19. Skilled nursing and rehabilitation facilities - choosing

    Science.gov (United States)

    ... gov/ency/patientinstructions/000436.htm Choosing a skilled nursing and rehabilitation facility To use the sharing features ... you may need to go to a skilled nursing or rehabilitation facility . Skilled nursing facilities provide care ...

  20. 48 CFR 970.3770 - Facilities management.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Facilities management. 970... REGULATIONS DOE MANAGEMENT AND OPERATING CONTRACTS Facilities Management Contracting 970.3770 Facilities management. ...

  1. EPA Facility Registry System (FRS): NCES

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  2. EPA Facility Registry Service (FRS): NEI

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  3. EPA Facility Registry Service (FRS): ICIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  4. EPA Facility Registry Service (FRS): CAMDBS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  5. Bidding strategy for an energy storage facility

    DEFF Research Database (Denmark)

    Nasrolahpour, Ehsan; Zareipour, Hamidreza; Rosehart, William D.

    2016-01-01

    This paper studies operation decisions of energy storage facilities in perfectly and imperfectly competitive markets. In a perfectly competitive market, the storage facility is operated to maximize the social welfare. However, in a imperfectly competitive market, the storage facility operates...

  6. EPA Facility Registry Service (FRS): RBLC

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  7. EPA Facility Registry System (FRS): NEPT

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  8. EPA Facility Registry Service (FRS): NCDB

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  9. EPA Facility Registry Service (FRS): BRAC

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  10. LAMPF: a nuclear research facility

    Energy Technology Data Exchange (ETDEWEB)

    Livingston, M.S.

    1977-09-01

    A description is given of the recently completed Los Alamos Meson Physics Facility (LAMPF) which is now taking its place as one of the major installations in this country for the support of research in nuclear science and its applications. Descriptions are given of the organization of the Laboratory, the Users Group, experimental facilities for research and for applications, and procedures for carrying on research studies.

  11. Two-sided Facility Location

    OpenAIRE

    Alijani, Reza; Banerjee, Siddhartha; Gollapudi, Sreenivas; Kollias, Kostas; Munagala, Kamesh

    2017-01-01

    Recent years have witnessed the rise of many successful e-commerce marketplace platforms like the Amazon marketplace, AirBnB, Uber/Lyft, and Upwork, where a central platform mediates economic transactions between buyers and sellers. Motivated by these platforms, we formulate a set of facility location problems that we term Two-sided Facility location. In our model, agents arrive at nodes in an underlying metric space, where the metric distance between any buyer and seller captures the quality...

  12. Plant Growth Facility (PGF)

    Science.gov (United States)

    1998-01-01

    In a microgravity environment aboard the Space Shuttle Columbia Life and Microgravity Mission STS-78, compression wood formation and hence altered lignin deposition and cell wall structure, was induced upon mechanically bending the stems of the woody gymnosperms, Douglas fir (Pseudotsuga menziesii) and loblolly pine (Pinus taeda). Although there was significant degradation of many of the plant specimens in space-flight due to unusually high temperatures experienced during the mission, it seems evident that gravity had little or no effect on compression wood formation upon bending even in microgravity. Instead, it apparently results from alterations in the stress gradient experienced by the plant itself during bending under these conditions. This preliminary study now sets the stage for long-term plant growth experiments to determine whether compression wood formation can be induced in microgravity during phototropic-guided realignment of growing woody plant specimens, in the absence of any externally provided stress and strain.

  13. Development of a fault test experimental facility model using Matlab

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Iraci Martinez; Moraes, Davi Almeida, E-mail: martinez@ipen.br, E-mail: dmoraes@dk8.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The Fault Test Experimental Facility was developed to simulate a PWR nuclear power plant and is instrumented with temperature, level and pressure sensors. The Fault Test Experimental Facility can be operated to generate normal and fault data, and these failures can be added initially small, and their magnitude being increasing gradually. This work presents the Fault Test Experimental Facility model developed using the Matlab GUIDE (Graphical User Interface Development Environment) toolbox that consists of a set of functions designed to create interfaces in an easy and fast way. The system model is based on the mass and energy inventory balance equations. Physical as well as operational aspects are taken into consideration. The interface layout looks like a process flowchart and the user can set the input variables. Besides the normal operation conditions, there is the possibility to choose a faulty variable from a list. The program also allows the user to set the noise level for the input variables. Using the model, data were generated for different operational conditions, both under normal and fault conditions with different noise levels added to the input variables. Data generated by the model will be compared with Fault Test Experimental Facility data. The Fault Test Experimental Facility theoretical model results will be used for the development of a Monitoring and Fault Detection System. (author)

  14. Analysis of material and energy flow in sewage treatment facilities in Japan.

    Science.gov (United States)

    Goto, N; Hu, H Y; Lim, B R; Fujie, K

    2001-05-01

    Energy consumption in sewage treatment facilities in Japan has increased due to increasing tap water consumption. To reduce the resource/energy consumption in sewage treatment facilities, measures such as the selection of optimum treatment processes and operating conditions should be considered. The objective of this study is to gather information necessary for the determination of optimum sewage treatment processes and optimum operating conditions. The energy consumption and material flow in sewage treatment facilities in Japan are analyzed using statistical data. In 1994, reuse rate of treated sewage outside the treatment facilities in Japan was 18% of the amount of domestic treated water. In this regard, reuse of water outside facilities should be encouraged. Average electric power consumption per unit volume of wastewater in sewage treatment facilities varies widely from facility to facility and closely correlates with the facility scale. For example, the smaller the facility scale, the larger the electric power consumption. Treatment volume of sewage in smaller facilities is much less than their capacity. 3.7 million t year-1 of dehydration cake is incinerated and 0.1 million t year-1 of it is converted by composting. The recycle rate of the cake was low. Developing a new sludge treatment process other than incineration is necessary.

  15. The Integral Test Facility Karlstein

    Directory of Open Access Journals (Sweden)

    Stephan Leyer

    2012-01-01

    Full Text Available The Integral Test Facility Karlstein (INKA test facility was designed and erected to test the performance of the passive safety systems of KERENA, the new AREVA Boiling Water Reactor design. The experimental program included single component/system tests of the Emergency Condenser, the Containment Cooling Condenser and the Passive Core Flooding System. Integral system tests, including also the Passive Pressure Pulse Transmitter, will be performed to simulate transients and Loss of Coolant Accident scenarios at the test facility. The INKA test facility represents the KERENA Containment with a volume scaling of 1 : 24. Component heights and levels are in full scale. The reactor pressure vessel is simulated by the accumulator vessel of the large valve test facility of Karlstein—a vessel with a design pressure of 11 MPa and a storage capacity of 125 m3. The vessel is fed by a benson boiler with a maximum power supply of 22 MW. The INKA multi compartment pressure suppression Containment meets the requirements of modern and existing BWR designs. As a result of the large power supply at the facility, INKA is capable of simulating various accident scenarios, including a full train of passive systems, starting with the initiating event—for example pipe rupture.

  16. Status of the SXFEL Facility

    Directory of Open Access Journals (Sweden)

    Zhentang Zhao

    2017-06-01

    Full Text Available The Shanghai soft X-ray Free-Electron Laser facility (SXFEL is being developed in two steps; the SXFEL test facility (SXFEL-TF, and the SXFEL user facility (SXFEL-UF. The SXFEL-TF is a critical development step towards the construction a soft X-ray FEL user facility in China, and is under commissioning at the Shanghai Synchrotron Radiation Facility (SSRF campus. The test facility is going to generate 8.8 nm FEL radiation using an 840 MeV electron linac passing through the two-stage cascaded HGHG-HGHG or EEHG-HGHG (high-gain harmonic generation, echo-enabled harmonic generation scheme. The construction of the SXFEL-TF started at the end of 2014. Its accelerator tunnel and klystron gallery were ready for equipment installation in April 2016, and the installation of the SXFEL-TF linac and radiator undulators were completed by the end of 2016. In the meantime, the SXFEL-UF, with a designated wavelength in the water window region, began construction in November 2016. This was based on upgrading the linac energy to 1.5 GeV, and the building of a second undulator line and five experimental end-stations. Construction status and the future plans of the SXFEL are reported in this paper.

  17. Site maps and facilities listings

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    In September 1989, a Memorandum of Agreement among DOE offices regarding the environmental management of DOE facilities was signed by appropriate Assistant Secretaries and Directors. This Memorandum of Agreement established the criteria for EM line responsibility. It stated that EM would be responsible for all DOE facilities, operations, or sites (1) that have been assigned to DOE for environmental restoration and serve or will serve no future production need; (2) that are used for the storage, treatment, or disposal of hazardous, radioactive, and mixed hazardous waste materials that have been properly characterized, packaged, and labelled, but are not used for production; (3) that have been formally transferred to EM by another DOE office for the purpose of environmental restoration and the eventual return to service as a DOE production facility; or (4) that are used exclusively for long-term storage of DOE waste material and are not actively used for production, with the exception of facilities, operations, or sites under the direction of the DOE Office of Civilian Radioactive Waste Management. As part of the implementation of the Memorandum of Agreement, Field Offices within DOE submitted their listings of facilities, systems, operation, and sites for which EM would have line responsibility. It is intended that EM facility listings will be revised on a yearly basis so that managers at all levels will have a valid reference for the planning, programming, budgeting and execution of EM activities.

  18. Space facilities: Meeting future needs for research, development, and operations

    Science.gov (United States)

    1994-01-01

    The National Facilities Study (NFS) represents an interagency effort to develop a comprehensive and integrated long-term plan for world-class aeronautical and space facilities that meet current and projected needs for commercial and government aerospace research and development and space operations. At the request of NASA and the DOD, the National Research Council's Committee on Space Facilities has reviewed the space related findings of the NFS. The inventory of more than 2800 facilities will be an important resource, especially if it continues to be updated and maintained as the NFS report recommends. The data in the inventory provide the basis for a much better understanding of the resources available in the national facilities infrastructure, as well as extensive information on which to base rational decisions about current and future facilities needs. The working groups have used the inventory data and other information to make a set of recommendations that include estimates of cast savings and steps for implementation. While it is natural that the NFS focused on cost reduction and consolidations, such a study is most useful to future planning if it gives equal weight to guiding the direction of future facilities needed to satisfy legitimate national aspirations. Even in the context of cost reduction through facilities closures and consolidations, the study is timid about recognizing and proposing program changes and realignments of roles and missions to capture what could be significant savings and increased effectiveness. The recommendations of the Committee on Space Facilities are driven by the clear need to be more realistic and precise both in recognizing current incentives and disincentives in the aerospace industry and in forecasting future conditions for U.S. space activities.

  19. Oil Pollution Act (OPA) and Federal Facilities

    Science.gov (United States)

    The Oil Pollution Prevention regulation sets forth requirements for prevention of, preparedness for, and response to oil discharges at specific non-transportation-related facilities, including federal facilities.

  20. Millimeter-wave Instrumentation Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Millimeter-wave Instrumentation Test Facility conducts basic research in propagation phenomena, remote sensing, and target signatures. The facility has a breadth...

  1. Thorium-U Recycle Facility (7930)

    Data.gov (United States)

    Federal Laboratory Consortium — The Thorium-U Recycle Facility (7930), along with the Transuranic Processing Facility (7920). comprise the Radiochemical Engineering Development Complex. 7930 is a...

  2. Commercial Light Water Reactor Tritium Extraction Facility

    Energy Technology Data Exchange (ETDEWEB)

    McHood, M D

    2000-10-12

    A geotechnical investigation program has been completed for the Commercial Light Water Reactor - Tritium Extraction Facility (CLWR-TEF) at the Savannah River Site (SRS). The program consisted of reviewing previous geotechnical and geologic data and reports, performing subsurface field exploration, field and laboratory testing, and geologic and engineering analyses. The purpose of this investigation was to characterize the subsurface conditions for the CLWR-TEF in terms of subsurface stratigraphy and engineering properties for design and to perform selected engineering analyses. The objectives of the evaluation were to establish site-specific geologic conditions, obtain representative engineering properties of the subsurface and potential fill materials, evaluate the lateral and vertical extent of any soft zones encountered, and perform engineering analyses for slope stability, bearing capacity and settlement, and liquefaction potential. In addition, provide general recommendations for construction and earthwork.

  3. The IPE facility in the ISS

    Science.gov (United States)

    Orr, Astrid

    IPE is a micro-gravity experiment that addresses planetary science. It is an ESA study in phase B and is intended to be installed on the Internaional Space Station. The goals of IPE are to: 1) understand the formation of planetesimals, or planet precursors, by studying the mutual interactions of micron-sized dust particles and their agglomeration in conditions representative of pre-planetary conditions 2) study the light scattering behavior of proto-planterary dust aggregates IPE (= ICAPS Precursor Experiment) is linked to a scientific program of ESA to study the Interactions in Cosmic and Atmospheric Particle systems under microgravity: ICAPS. The IPE collaboration includes an international Facility Science Team composed of leading scientists from France, Germany, Belgium, Canada and Spain. It also envolves a European industrial consortium. This paper will present the current status of the IPE project, the scientific objectives and the current payload configuration.

  4. EPA Facility Registry Service (FRS): Facility Interests Dataset

    Science.gov (United States)

    This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in the FRS individual feature layers. The layers comprise the FRS major program databases, including:Assessment Cleanup and Redevelopment Exchange System (ACRES) : brownfields sites ; Air Facility System (AFS) : stationary sources of air pollution ; Air Quality System (AQS) : ambient air pollution data from monitoring stations; Bureau of Indian Affairs (BIA) : schools data on Indian land; Base Realignment and Closure (BRAC) facilities; Clean Air Markets Division Business System (CAMDBS) : market-based air pollution control programs; Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) : hazardous waste sites; Integrated Compliance Information System (ICIS) : integrated enforcement and compliance information; National Compliance Database (NCDB) : Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and the Toxic Substances Control Act (TSCA); National Pollutant Discharge Elimination System (NPDES) module of ICIS : NPDES surface water permits; Radiation Information Database (RADINFO) : radiation and radioactivity facilities; RACT/BACT/LAER Clearinghouse (RBLC) : best available air pollution technology requirements; Resource Conservation and Recovery Act Information System (RCRAInfo) : tracks generators, transporters, treaters, storers, and disposers of haz

  5. Manual for operation of the multipurpose thermalhydraulic test facility TOPFLOW (Transient Two Phase Flow Test Facility); Betriebshandbuch fuer die Mehrzweck-Thermohydraulikversuchsanlage TOPFLOW

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, M.; Carl, H.; Schuetz, H.; Pietruske, H.; Lenk, S. [SAAS Systemanalyse und Automatisierungsservice GmbH, Possendorf (Germany)

    2004-07-01

    The Forschungszentrum Rossendorf (FZR) e. V. is constructing a new large-scale test facility, TOPFLOW, for thermalhydraulic single effect tests. The acronym stands for transient two phase flow test facility. It will mainly be used for the investigation of generic and applied steady state and transient two phase flow phenomena and the development and validation of models of computational fluid dynamic (CFD) codes. The manual of the test facility must always be available for the staff in the control room and is restricted condition during operation of personnel and also reconstruction of the facility. (orig./GL)

  6. Facility effluent monitoring plan for the tank farms facilities

    Energy Technology Data Exchange (ETDEWEB)

    Bachand, D.D.; Crummel, G.M.

    1995-05-01

    A facility effluent monitoring plan is required by the US Department of Energy for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using specific guidelines. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years.

  7. Potable Water Treatment Facility General Permit (PWTF GP) ...

    Science.gov (United States)

    2017-08-28

    The Final PWTF GP establishes permit eligibility conditions, Notice of Intent (NOI) requirements, effluent limitations, standards, prohibitions, and best management practices for facilities that discharge to waters in the Commonwealth of Massachusetts (including both Commonwealth and Indian country lands) and the State of New Hampshire.

  8. Facile synthesis of monodisperse thermally immiscible Ag–Ni alloy ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 37; Issue 6. Facile synthesis of monodisperse thermally ... Using Tetrakis hydroxymethyl phosphonium chloride resulted in construction of near-uniform ANPs in the easily controllable conditions of the present alloying procedure. Nanoparticles having up to 65% Ni were ...

  9. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    Energy Technology Data Exchange (ETDEWEB)

    Coenenberg, J.G.

    1997-08-15

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, `operating` treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit application guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating

  10. Integrated Facilities and Infrastructure Plan.

    Energy Technology Data Exchange (ETDEWEB)

    Reisz Westlund, Jennifer Jill

    2017-03-01

    Our facilities and infrastructure are a key element of our capability-based science and engineering foundation. The focus of the Integrated Facilities and Infrastructure Plan is the development and implementation of a comprehensive plan to sustain the capabilities necessary to meet national research, design, and fabrication needs for Sandia National Laboratories’ (Sandia’s) comprehensive national security missions both now and into the future. A number of Sandia’s facilities have reached the end of their useful lives and many others are not suitable for today’s mission needs. Due to the continued aging and surge in utilization of Sandia’s facilities, deferred maintenance has continued to increase. As part of our planning focus, Sandia is committed to halting the growth of deferred maintenance across its sites through demolition, replacement, and dedicated funding to reduce the backlog of maintenance needs. Sandia will become more agile in adapting existing space and changing how space is utilized in response to the changing requirements. This Integrated Facilities & Infrastructure (F&I) Plan supports the Sandia Strategic Plan’s strategic objectives, specifically Strategic Objective 2: Strengthen our Laboratories’ foundation to maximize mission impact, and Strategic Objective 3: Advance an exceptional work environment that enables and inspires our people in service to our nation. The Integrated F&I Plan is developed through a planning process model to understand the F&I needs, analyze solution options, plan the actions and funding, and then execute projects.

  11. AGING FACILITY WORKER DOSE ASSESSMENT

    Energy Technology Data Exchange (ETDEWEB)

    R.L. Thacker

    2005-03-24

    The purpose of this calculation is to estimate radiation doses received by personnel working in the Aging Facility performing operations to transfer aging casks to the aging pads for thermal and logistical management, stage empty aging casks, and retrieve aging casks from the aging pads for further processing in other site facilities. Doses received by workers due to aging cask surveillance and maintenance operations are also included. The specific scope of work contained in this calculation covers both collective doses and individual worker group doses on an annual basis, and includes the contributions due to external and internal radiation from normal operation. There are no Category 1 event sequences associated with the Aging Facility (BSC 2004 [DIRS 167268], Section 7.2.1). The results of this calculation will be used to support the design of the Aging Facility and to provide occupational dose estimates for the License Application. The calculations contained in this document were developed by Environmental and Nuclear Engineering of the Design and Engineering Organization and are intended solely for the use of the Design and Engineering Organization in its work regarding facility operation. Yucca Mountain Project personnel from the Environmental and Nuclear Engineering should be consulted before use of the calculations for purposes other than those stated herein or use by individuals other than authorized personnel in Environmental and Nuclear Engineering.

  12. Security culture for nuclear facilities

    Science.gov (United States)

    Gupta, Deeksha; Bajramovic, Edita

    2017-01-01

    Natural radioactive elements are part of our environment and radioactivity is a natural phenomenon. There are numerous beneficial applications of radioactive elements (radioisotopes) and radiation, starting from power generation to usages in medical, industrial and agriculture applications. But the risk of radiation exposure is always attached to operational workers, the public and the environment. Hence, this risk has to be assessed and controlled. The main goal of safety and security measures is to protect human life, health, and the environment. Currently, nuclear security considerations became essential along with nuclear safety as nuclear facilities are facing rapidly increase in cybersecurity risks. Therefore, prevention and adequate protection of nuclear facilities from cyberattacks is the major task. Historically, nuclear safety is well defined by IAEA guidelines while nuclear security is just gradually being addressed by some new guidance, especially the IAEA Nuclear Security Series (NSS), IEC 62645 and some national regulations. At the overall level, IAEA NSS 7 describes nuclear security as deterrence and detection of, and response to, theft, sabotage, unauthorized access, illegal transfer or other malicious acts involving nuclear, other radioactive substances and their associated facilities. Nuclear security should be included throughout nuclear facilities. Proper implementation of a nuclear security culture leads to staff vigilance and a high level of security posture. Nuclear security also depends on policy makers, regulators, managers, individual employees and members of public. Therefore, proper education and security awareness are essential in keeping nuclear facilities safe and secure.

  13. Decision-making factors affecting different family members regarding the placement of relatives in long-term care facilities

    OpenAIRE

    Huang, Ying-Chia; Chu, Chiao-Lee; Ho, Ching-Sung; Lan, Shou-Jen; Hsieh, Chen-Hsi; Hsieh, Yen-Ping

    2014-01-01

    Background The aim of this research was to investigate factors affecting different family members’ decisions regarding the placement of relatives in long-term car (LTC) facilities in Taiwan. The objective was to investigate the correlations between family members’ personal traits, the living conditions of residents in the LTC facilities, and family members’ experiences with LTC facilities. Methods This study selected family members visiting residents in LTC facilities as research subjects and...

  14. Experiment/facility requirements document for the Space Station Furnace Facility. Section 1: Integrated configuration

    Science.gov (United States)

    1992-01-01

    The function of the Space Station Furnace Facility (SSFF) is to support materials research into the crystal growth and solidification processes of electronic and photonic materials, metals and alloys, and glasses and ceramics. To support this broad base of research requirements, the SSFF will employ a variety of furnace modules which will be operated, regulated, and supported by a core of common subsystems. Furnace modules may be reconfigured or specifically developed to provide unique solidification conditions for each set of experiments. The SSFF modular approach permits the addition of new or scaled-up furnace modules to support the evolution of the facility as new science requirements are identified. The SSFF Core is of modular design to permit augmentation for enhanced capabilities. The fully integrated configuration of the SSFF will consist of three racks with the capability of supporting up to two furnace modules per rack. The initial configuration of the SSFF will consist of two of the three racks and one furnace module. This Experiment/Facility Requirements Document (E/FRD) describes the integrated facility requirements for the Space Station Freedom (SSF) Integrated Configuration-1 (IC1) mission. The IC1 SSFF will consist of two racks: the Core Rack, with the centralized subsystem equipment; and the Experiment Rack-1, with Furnace Module-1 and the distributed subsystem equipment to support the furnace. The SSFF support functions are provided by the following Core subsystems: power conditioning and distribution subsystem (SSFF PCDS); data management subsystem (SSFF DMS); thermal control Subsystem (SSFF TCS); gas distribution subsystem (SSFF GDS); and mechanical structures subsystem (SSFF MSS).

  15. Aggregation and non aggregation techniques for large facility location problems: A survey

    Directory of Open Access Journals (Sweden)

    Irawan Chandra Ade

    2015-01-01

    Full Text Available A facility location problem is concerned with determining the location of some useful facilities in such a way so to fulfil one or a few objective functions and constraints. We survey those problems where, in the presence of a large number of customers, some form of aggregation may be required. In addition, a review on conditional location problems where some (say q facilities already exist in the study area is presented.

  16. HANFORD FACILITY ANNUAL DANGEROUS WASTE REPORT CY2005

    Energy Technology Data Exchange (ETDEWEB)

    SKOLRUD, J.O.

    2006-02-15

    The Hanford Facility Annual Dangerous Waste Report (ADWR) is prepared to meet the requirements of Washington Administrative Code Sections 173-303-220, Generator Reporting, and 173-303-390, Facility Reporting. In addition, the ADWR is required to meet Hanford Facility RCR4 Permit Condition I.E.22, Annual Reporting. The ADWR provides summary information on dangerous waste generation and management activities for the Calendar Year for the Hanford Facility EPA ID number assigned to the Department of Energy for RCRA regulated waste, as well as Washington State only designated waste and radioactive mixed waste. An electronic database is utilized to collect and compile the large array of data needed for preparation of this report. Information includes details of waste generated on the Hanford Facility, waste generated offsite and sent to Hanford for management, and other waste management activities conducted at Hanford, including treatment, storage, and disposal. Report details consist of waste descriptions and weights, waste codes and designations, and waste handling codes, In addition, for waste shipped to Hanford for treatment and/or disposal, information on manifest numbers, the waste transporter, the waste receiving facility, and the original waste generators are included. In addition to paper copies, the report is also transmitted electronically to a web site maintained by the Washington State Department of Ecology.

  17. Documented Safety Analysis for the Waste Storage Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Laycak, D

    2008-06-16

    This documented safety analysis (DSA) for the Waste Storage Facilities was developed in accordance with 10 CFR 830, Subpart B, 'Safety Basis Requirements', and utilizes the methodology outlined in DOE-STD-3009-94, Change Notice 3. The Waste Storage Facilities consist of Area 625 (A625) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area portion of the DWTF complex. These two areas are combined into a single DSA, as their functions as storage for radioactive and hazardous waste are essentially identical. The B695 Segment of DWTF is addressed under a separate DSA. This DSA provides a description of the Waste Storage Facilities and the operations conducted therein; identification of hazards; analyses of the hazards, including inventories, bounding releases, consequences, and conclusions; and programmatic elements that describe the current capacity for safe operations. The mission of the Waste Storage Facilities is to safely handle, store, and treat hazardous waste, transuranic (TRU) waste, low-level waste (LLW), mixed waste, combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL (as well as small amounts from other DOE facilities).

  18. Documented Safety Analysis for the Waste Storage Facilities March 2010

    Energy Technology Data Exchange (ETDEWEB)

    Laycak, D T

    2010-03-05

    This Documented Safety Analysis (DSA) for the Waste Storage Facilities was developed in accordance with 10 CFR 830, Subpart B, 'Safety Basis Requirements,' and utilizes the methodology outlined in DOE-STD-3009-94, Change Notice 3. The Waste Storage Facilities consist of Area 625 (A625) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area portion of the DWTF complex. These two areas are combined into a single DSA, as their functions as storage for radioactive and hazardous waste are essentially identical. The B695 Segment of DWTF is addressed under a separate DSA. This DSA provides a description of the Waste Storage Facilities and the operations conducted therein; identification of hazards; analyses of the hazards, including inventories, bounding releases, consequences, and conclusions; and programmatic elements that describe the current capacity for safe operations. The mission of the Waste Storage Facilities is to safely handle, store, and treat hazardous waste, transuranic (TRU) waste, low-level waste (LLW), mixed waste, combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL (as well as small amounts from other DOE facilities).

  19. A Bioinformatics Facility for NASA

    Science.gov (United States)

    Schweighofer, Karl; Pohorille, Andrew

    2006-01-01

    Building on an existing prototype, we have fielded a facility with bioinformatics technologies that will help NASA meet its unique requirements for biological research. This facility consists of a cluster of computers capable of performing computationally intensive tasks, software tools, databases and knowledge management systems. Novel computational technologies for analyzing and integrating new biological data and already existing knowledge have been developed. With continued development and support, the facility will fulfill strategic NASA s bioinformatics needs in astrobiology and space exploration. . As a demonstration of these capabilities, we will present a detailed analysis of how spaceflight factors impact gene expression in the liver and kidney for mice flown aboard shuttle flight STS-108. We have found that many genes involved in signal transduction, cell cycle, and development respond to changes in microgravity, but that most metabolic pathways appear unchanged.

  20. High Power RF Test Facility at the SNS

    CERN Document Server

    Kang, Yoon W; Campisi, Isidoro E; Champion, Mark; Crofford, Mark; Davis, Kirk; Drury, Michael A; Fuja, Ray E; Gurd, Pamela; Kasemir, Kay-Uwe; McCarthy, Michael P; Powers, Tom; Shajedul Hasan, S M; Stirbet, Mircea; Stout, Daniel; Tang, Johnny Y; Vassioutchenko, Alexandre V; Wezensky, Mark

    2005-01-01

    RF Test Facility has been completed in the SNS project at ORNL to support test and conditioning operation of RF subsystems and components. The system consists of two transmitters for two klystrons powered by a common high voltage pulsed converter modulator that can provide power to two independent RF systems. The waveguides are configured with WR2100 and WR1150 sizes for presently used frequencies: 402.5 MHz and 805 MHz. Both 402.5 MHz and 805 MHz systems have circulator protected klystrons that can be powered by the modulator capable of delivering 11 MW peak and 1 MW average power. The facility has been equipped with computer control for various RF processing and complete dual frequency operation. More than forty 805 MHz fundamental power couplers for the SNS superconducting linac (SCL) cavitites have been RF conditioned in this facility. The facility provides more than 1000 ft2 floor area for various test setups. The facility also has a shielded cave area that can support high power tests of normal conducti...

  1. Facility Management's Role in Organizational Sustainability

    Science.gov (United States)

    Adams, Gregory K.

    2013-01-01

    Facility managers have questions about sustainability. How do an organization's physical facilities--its built environment--and the management of them, influence the sustainability of the organization or institution as a whole? How important is Facility Management (FM) to the overall sustainability profile of an organization? Facility managers…

  2. An Information Framework for Facility Operators

    Science.gov (United States)

    1991-01-01

    Information Organization ................................................................................. 82 6.2.2. Identifying Facility Operators Information...overview of facility operations. The chapter identified information organization as the topic of the thesis and addressed a major problem facing...below. 82 6.2.1. Defining Facility Operations and Information Organization The first objective involved defining the role of the facility operator and

  3. 30 CFR 57.20008 - Toilet facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Toilet facilities. 57.20008 Section 57.20008....20008 Toilet facilities. (a) Toilet facilities shall be provided at locations that are compatible with... kept clean and sanitary. Separate toilet facilities shall be provided for each sex except where toilet...

  4. 30 CFR 56.20008 - Toilet facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Toilet facilities. 56.20008 Section 56.20008... Toilet facilities. (a) Toilet facilities shall be provided at locations that are compatible with the mine... sanitary. Separate toilet facilities shall be provided for each sex except where toilet rooms will be...

  5. The Biological Flight Research Facility

    Science.gov (United States)

    Johnson, Catherine C.

    1993-01-01

    NASA Ames Research Center (ARC) is building a research facility, the Biological Flight Research Facility (BFRF), to meet the needs of life scientists to study the long-term effects of variable gravity on living systems. The facility will be housed on Space Station Freedom and is anticipated to operate for the lifetime of the station, approximately thirty years. It will allow plant and animal biologists to study the role of gravity, or its absence, at varying gravity intensities for varying periods of time and with various organisms. The principal difference between current Spacelab missions and those on Space Station Freedom, other than length of mission, will be the capability to perform on-orbit science procedures and the capability to simulate earth gravity. Initially the facility will house plants and rodents in habitats which can be maintained at microgravity or can be placed on a 2.5 meter diameter centrifuge. However, the facility is also being designed to accommodate future habitats for small primates, avian, and aquatic specimens. The centrifuge will provide 1 g for controls and will also be able to provide gravity from 0.01 to 2.0 g for threshold gravity studies as well as hypergravity studies. Included in the facility are a service unit for providing clean chambers for the specimens and a glovebox for manipulating the plant and animal specimens and for performing experimental protocols. The BFRF will provide the means to conduct basic experiments to gain an understanding of the effects of microgravity on the structure and function of plants and animals, as well as investigate the role of gravity as a potential countermeasure for the physiological changes observed in microgravity.

  6. Hot Fuel Examination Facility/North Facility safety report

    Energy Technology Data Exchange (ETDEWEB)

    Adams, R.M.; Hampson, D.C.; Ferguson, K.R.; Hylsky, E.

    1975-02-01

    Design and safety-related construction features of the Hot Fuel Examination Facility/North, located on the Argonne--West site at the Idaho National Engineering Laboratory are described. The proposed operations, the organizational structure, and emergency plans are given. Evaluations of potential accident situations are presented and it is concluded that HFEF/N can be operated safely and without undue hazard.

  7. Tandem mirror technology demonstration facility

    Energy Technology Data Exchange (ETDEWEB)

    1983-10-01

    This report describes a facility for generating engineering data on the nuclear technologies needed to build an engineering test reactor (ETR). The facility, based on a tandem mirror operating in the Kelley mode, could be used to produce a high neutron flux (1.4 MW/M/sup 2/) on an 8-m/sup 2/ test area for testing fusion blankets. Runs of more than 100 h, with an average availability of 30%, would produce a fluence of 5 mW/yr/m/sup 2/ and give the necessary experience for successful operation of an ETR.

  8. Laundry monitor for nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Ishibashi, Mitsuo (Toshiba Corp., Fuchu (Japan). Fuchu Works)

    1984-06-01

    A laundry monitor has been developed for the detection and cleansification of radiation contamination on the clothes, headgear, footgear, etc. of workers in nuclear facilities. With this monitor, measurement is made irrespective of the size and shape of the objects; a large-area plastic scintillation detector is incorporated; it has stable and highly sensitive characteristics, with the merits of swift measurement, economical operation and easy maintenance. Connected with a folding machine, automatic carrying and storing compartment through a conveyor, it is capable of saving energy and man power, contributing to scheduled operation, and improving the efficiency of the facilities.

  9. Fire detection in warehouse facilities

    CERN Document Server

    Dinaburg, Joshua

    2013-01-01

    Automatic sprinklers systems are the primary fire protection system in warehouse and storage facilities. The effectiveness of this strategy has come into question due to the challenges presented by modern warehouse facilities, including increased storage heights and areas, automated storage retrieval systems (ASRS), limitations on water supplies, and changes in firefighting strategies. The application of fire detection devices used to provide early warning and notification of incipient warehouse fire events is being considered as a component of modern warehouse fire protection.Fire Detection i

  10. NIST display colorimeter calibration facility

    Science.gov (United States)

    Brown, Steven W.; Ohno, Yoshihiro

    2003-07-01

    A facility has been developed at the National Institute of Standards and Technology (NIST) to provide calibration services for color-measuring instruments to address the need for improving and certifying the measurement uncertainties of this type of instrument. While NIST has active programs in photometry, flat panel display metrology, and color and appearance measurements, these are the first services offered by NIST tailored to color-measuring instruments for displays. An overview of the facility, the calibration approach, and associated uncertainties are presented. Details of a new tunable colorimetric source and the development of new transfer standard instruments are discussed.

  11. 42 CFR 485.62 - Condition of participation: Physical environment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition of participation: Physical environment... of participation: Physical environment. The facility must provide a physical environment that...) Standard: Sanitary environment. The facility must maintain a sanitary environment and establish a program...

  12. A new lab facility for measuring bidirectional reflectance/emittance distribution functions of soils and canopies

    NARCIS (Netherlands)

    Clevers, J.G.P.W.; Bartholomeus, H.; Schaepman, M.E.; Schaepman-Strub, G.; Jalink, H.; Schoor, van der R.; Jong, de A.; Uiterwijk, M.

    2011-01-01

    Recently, a laboratory measurement facility has been realized for assessing the anisotropic reflectance and emittance behaviour of soils, leaves and small canopies under controlled illumination conditions. The facility consists of an ASD FieldSpec 3 spectroradiometer covering the spectral range from

  13. Establishing Links Between U.S. Army Facility Attributes and Mission Requirements

    Science.gov (United States)

    1992-06-01

    Logistics WarehouseC Storage Fac Services Soldier/Family Hospital Dental Soldier Indirect Relations Figure 1. Facility/Mission Relationships. Historical...To Determine the Extent of Social Support and Burnout Among Nurses at Womack Army Community Hospital , 105-98/ADA220170 (Womack General Hospital , Fort...Amount Adequacy Condition ability Flexibility Appearance Pmxinity Ranges & Training Grounds * Classrom Facilities Maintenance Facilites * Medical

  14. The Pain in Storage: Work Safety in a High-Density Shelving Facility

    Science.gov (United States)

    Atkins, Stephanie A.

    2005-01-01

    An increasing number of academic and research libraries have built high-density shelving facilities to address overcrowding conditions in their regular stacks. However, the work performed in these facilities is physically strenuous and highly repetitive in nature and may require the use of potentially dangerous equipment. This article will examine…

  15. Measuring relative humidity in the radioactive environment of the IRRAD proton facility

    CERN Document Server

    Paerg, Marten

    2017-01-01

    The aim of the project was to obtain information on relative humidity conditions at different locations in the IRRAD proton facility. Due to high radiation levels inside the facility, different sensors had to be qualified and dedicated electronics had to be built to transfer the data of the sensors over long wires to a less radioactive area, where it could be collected.

  16. El Cabril Facilities; Instalaciones de El Cabril

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, A.; Zuloaga, P. [ENRESA. Madrid (Spain)

    2000-07-01

    The El Cabril facilities have been designed such that they may be used for the long-term disposal of low and intermediate level radioactive wastes. For this purpose, the design has been carried out in accordance with general criteria of: Ensuring the immediate and deferred protection for people and the environment. Allowing for the free use of the site following a period of at most 300 years, without radiological limitations. Furthermore, a basic objective sought in the design of El Cabril has been the possibility of recovering the wastes if circumstances were to make this advisable. The disposal system is based on the creation of barriers around the materials to be treated, for which the 220-liter drums containing the wastes are stored inside concrete containers, which are located in the disposal cells. The main core of the facilities consists of the disposal zone and the buildings area. Twenty-eight cells have been constructed in the first of these zones, grouped into two areas or platforms: the north platform, with 16 structures, and the south platform, with 12 (To date the ninth cell has been completed and closed and the tenth is now being filled). The buildings area contains the auxiliary installations for the treatment and conditioning of the wastes and for their control, along with the auxiliary services required for the operation and maintenance of the Facility. The installation is equipped with a verification laboratory supporting the waste acceptance and characterization activities and for technical verification of the waste packages. This laboratory is fitted with the equipment required for sampling, mechanical testing, the extraction of dry test pieces, etc. The laboratory is completed with a waste package radiological characterization system (non-destructive characterization by gamma spectrometry). a system for the leach testing of drums (decorticated) and test pieces, a radiochemistry laboratory and a counting room. (Author)

  17. Mobile terawatt laser propagation facility (Conference Presentation)

    Science.gov (United States)

    Shah, Lawrence; Roumayah, Patrick; Bodnar, Nathan; Bradford, Joshua D.; Maukonen, Douglas; Richardson, Martin C.

    2017-03-01

    This presentation will describe the design and construction status of a new mobile high-energy femtosecond laser systems producing 500 mJ, 100 fs pulses at 10 Hz. This facility is built into a shipping container and includes a cleanroom housing the laser system, a separate section for the beam director optics with a retractable roof, and the environmental control equipment necessary to maintain stable operation. The laser system includes several innovations to improve the utility of the system for "in field" experiments. For example, this system utilizes a fiber laser oscillator and a monolithic chirped Bragg grating stretcher to improve system robustness/size and employs software to enable remote monitoring and system control. Uniquely, this facility incorporates a precision motion-controlled gimbal altitude-azimuth mount with a coudé path to enable aiming of the beam over a wide field of view. In addition to providing the ability to precisely aim at multiple targets, it is also possible to coordinate the beam with separate tracking/diagnostic sensing equipment as well as other laser systems. This mobile platform will be deployed at the Townes Institute Science and Technology Experimental Facility (TISTEF) located at the Kennedy Space Center in Florida, to utilize the 1-km secured laser propagation range and the wide array of meteorological instrumentation for atmospheric and turbulence characterization. This will provide significant new data on the propagation of high peak power ultrashort laser pulses and detailed information on the atmospheric conditions in a coastal semi-tropical environment.

  18. Reliability centered maintenance in astronomical infrastructure facilities

    Science.gov (United States)

    Ansorge, W. R.

    2006-06-01

    Hundreds of mirror segment, thousands of high precision actuators, highly complex mechanical, hydraulic, electrical and other technology subsystems, and highly sophisticated control systems: an ELT system consists of millions of individual parts and components, each of them may fail and lead to a partial or complete system breakdown. The traditional maintenance concepts characterized by predefined preventive maintenance activities and rigid schedules are not suitable for handling this large number of potential failures and malfunctions and the extreme maintenance workload. New maintenance strategies have to be found suitable to increase reliability while reducing the cost of needless maintenance services. The Reliability Centred Maintenance (RCM) methodology is already used extensively by airlines, and in industrial and marine facilities and even by scientific institutions like NASA. Its application increases the operational reliability while reducing the cost of unnecessary maintenance activities and is certainly also a solution for current and future ELT facilities. RCM is a concept of developing a maintenance scheme based on the reliability of the various components of a system by using "feedback loops between instrument / system performance monitoring and preventive/corrective maintenance cycles." Ideally RCM has to be designed within a system and should be located in the requirement definition, the preliminary and final design phases of new equipment and complicated systems. However, under certain conditions, an implementation of RCM into the maintenance management strategy of already existing astronomical infrastructure facilities is also possible. This presentation outlines the principles of the RCM methodology, explains the advantages, and highlights necessary changes in the observatory development, operation and maintenance philosophies. Presently, it is the right time to implement RCM into current and future ELT projects and to save up to 50% maintenance

  19. Universal Design for Academic Facilities

    Science.gov (United States)

    Salmen, John P. S.

    2011-01-01

    Universal design (UD) can play a role in many aspects of academic life and is often thought of in the context of learning. However, this chapter focuses on the impact of UD on the design of facilities in a university or campus setting. Universal design has the potential for transforming universities into truly egalitarian institutions that…

  20. Holifield heavy ion research facility

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.M.; Alton, G.D.; Ball, J.B.; Biggerstaff, J.A.; Dowling, D.T.; Erb, K.A.; Haynes, D.L.; Hoglund, D.E.; Hudson, E.D.; Juras, R.C.

    1988-05-20

    Development of the Holifield facility has continued with resulting improvements in the number of ion species provided, in the ion energy for tandem-only operations, and in utilization efficiency. In this report, we describe our recent operational experience, development activities, and future development plans.

  1. The Facilities Management Value Map

    DEFF Research Database (Denmark)

    Jensen, Per Anker

    2008-01-01

    The paper is based on research from 21 cases studies on Facilities Management (FM) in the Nordic countries. The work also relates to a working group on “Highlighting the Added Value of FM” under Nordic FM. The aim has been to establish a conceptual framework to discuss, understand and explain...

  2. Utilizing Interns in Facilities Management

    Science.gov (United States)

    Judkins, Clarissa; Morris, John P.; Molocznik, Chuck

    2011-01-01

    Facilities management is rapidly changing and developing from a position an individual stumbles into--or work one's way up through--to a discipline and vocation all of its own. There is a need for a collaborative strategy among leaders in practice, education, and research to share knowledge and experience and to establish professional and ethical…

  3. Weapons engineering tritium facility overview

    Energy Technology Data Exchange (ETDEWEB)

    Najera, Larry [Los Alamos National Laboratory

    2011-01-20

    Materials provide an overview of the Weapons Engineering Tritium Facility (WETF) as introductory material for January 2011 visit to SRS. Purpose of the visit is to discuss Safety Basis, Conduct of Engineering, and Conduct of Operations. WETF general description and general GTS program capabilities are presented in an unclassified format.

  4. (ICSID) ADDITIONAL FACILITY IN INTERNA

    African Journals Online (AJOL)

    Fr. Ikenga

    Traditionally, ICSID is. “a forum for investor-state arbitration and conciliation”2, which focuses on settlement of legal disputes arising directly out of investment between “contracting” states or state entities and nationals of other. “Contracting” states which the parties consent in writing to submit to the centre.3 Additional facility.

  5. Medical facility statistics in Japan.

    Science.gov (United States)

    Hamajima, Nobuyuki; Sugimoto, Takuya; Hasebe, Ryo; Myat Cho, Su; Khaing, Moe; Kariya, Tetsuyoshi; Mon Saw, Yu; Yamamoto, Eiko

    2017-11-01

    Medical facility statistics provide essential information to policymakers, administrators, academics, and practitioners in the field of health services. In Japan, the Health Statistics Office of the Director-General for Statistics and Information Policy at the Ministry of Health, Labour and Welfare is generating these statistics. Although the statistics are widely available in both Japanese and English, the methodology described in the technical reports are primarily in Japanese, and are not fully described in English. This article aimed to describe these processes for readers in the English-speaking world. The Health Statistics Office routinely conduct two surveys called the Hospital Report and the Survey of Medical Institutions. The subjects of the former are all the hospitals and clinics with long-term care beds in Japan. It comprises a Patient Questionnaire focusing on the numbers of inpatients, admissions, discharges, and outpatients in one month, and an Employee Questionnaire, which asks about the number of employees as of October 1. The Survey of Medical Institutions consists of the Dynamic Survey, which focuses on the opening and closing of facilities every month, and the Static Survey, which focuses on staff, facilities, and services as of October 1, as well as the number of inpatients as of September 30 and the total number of outpatients during September. All hospitals, clinics, and dental clinics are requested to submit the Static Survey questionnaire every three years. These surveys are useful tools for collecting essential information, as well as providing occasions to implicitly inform facilities of the movements of government policy.

  6. Facilities Management and Added Value

    DEFF Research Database (Denmark)

    Jensen, Per Anker

    2010-01-01

    Aim: This paper aims to present different models of the concept of the added value of Facilities Management (FM), including the FM Value Map, which forms the basis of research group in EuroFM, and to present some of the results of this research collaboration. Approach and methodology: The paper i...

  7. Refining the W1 and SE1 Facilities

    Science.gov (United States)

    Chambers, Rodney D.

    2004-01-01

    The Engine Research Building (ERB) houses more than 60 test rigs that study all aspects of engine development. By working with Mary Gibson in the SE1 and W1A Turbine Facilities, I became aware of her responsibilities and better acquainted with the inner workings of the ERB. The SE1 Supersonic/Subsonic Wind Tunnel Facility contains 2 small wind tunnels. The first tunnel uses an atmospheric inlet, while the second uses treated 40-psig air. Both of the tunnels are capable of subsonic and supersonic operation. An auxiliary air supply and exhaust piping providing both test sections with suction, blowing, and crossfire capabilities. The current configuration of SE1 consists of a curved diffuser that studies the blockage along the endwalls. The W1A Low Speed Compressor Facility provides insight for the complex flow phenomena within its 4-stage axial compressor, sand the data obtained from W 1A is used to develop advanced models for fluid dynamic assessment. W1A is based off of a low speed research compressor developed by GE in the 1950's. This compressor has a removable casing treatment under rotor 1, which allows for various tip treatment studies. The increased size and low speed allows instrumentation to be located in the compressor s complex flow paths. Air enters the facility through a filtered roof vent, conditioned for temperature and turbulence, and then passed through the compressor W1A is described as a dynamic facility with many projects taking place simultaneously. This current environment makes it challenging to follow the various affairs that are taking place within the area. During my first 4 weeks at the NASA Glenn Research Center, I have assisted Mary Gibson in multiple tasks such as facility documents, record keeping, maintenance and upgrades. The facility has lube systems for its gearbox and compressor. These systems are critical in the successful operation of the facility. I was assigned the task of creating a facility estimate list, which included the

  8. PROJECTIZING AN OPERATING NUCLEAR FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    Adams, N

    2007-07-08

    This paper will discuss the evolution of an operations-based organization to a project-based organization to facilitate successful deactivation of a major nuclear facility. It will describe the plan used for scope definition, staff reorganization, method estimation, baseline schedule development, project management training, and results of this transformation. It is a story of leadership and teamwork, pride and success. Workers at the Savannah River Site's (SRS) F Canyon Complex (FCC) started with a challenge--take all the hazardous byproducts from nearly 50 years of operations in a major, first-of-its-kind nuclear complex and safely get rid of them, leaving the facility cold, dark, dry and ready for whatever end state is ultimately determined by the United States Department of Energy (DOE). And do it in four years, with a constantly changing workforce and steadily declining funding. The goal was to reduce the overall operating staff by 93% and budget by 94%. The facilities, F Canyon and its adjoined sister, FB Line, are located at SRS, a 310-square-mile nuclear reservation near Aiken, S.C., owned by DOE and managed by Washington Group International subsidiary Washington Savannah River Company (WSRC). These facilities were supported by more than 50 surrounding buildings, whose purpose was to provide support services during operations. The radiological, chemical and industrial hazards inventory in the old buildings was significant. The historical mission at F Canyon was to extract plutonium-239 and uranium-238 from irradiated spent nuclear fuel through chemical processing. FB Line's mission included conversion of plutonium solutions into metal, characterization, stabilization and packaging, and storage of both metal and oxide forms. The plutonium metal was sent to another DOE site for use in weapons. Deactivation in F Canyon began when chemical separations activities were completed in 2002, and a cross-functional project team concept was implemented to

  9. Europlanet Research Infrastructure: Planetary Simulation Facilities

    Science.gov (United States)

    Davies, G. R.; Mason, N. J.; Green, S.; Gómez, F.; Prieto, O.; Helbert, J.; Colangeli, L.; Srama, R.; Grande, M.; Merrison, J.

    2008-09-01

    EuroPlanet The Europlanet Research Infrastructure consortium funded under FP7 aims to provide the EU Planetary Science community greater access for to research infrastructure. A series of networking and outreach initiatives will be complimented by joint research activities and the formation of three Trans National Access distributed service laboratories (TNA's) to provide a unique and comprehensive set of analogue field sites, laboratory simulation facilities, and extraterrestrial sample analysis tools. Here we report on the infrastructure that comprises the second TNA; Planetary Simulation Facilities. 11 laboratory based facilities are able to recreate the conditions found in the atmospheres and on the surfaces of planetary systems with specific emphasis on Martian, Titan and Europa analogues. The strategy has been to offer some overlap in capabilities to ensure access to the highest number of users and to allow for progressive and efficient development strategies. For example initial testing of mobility capability prior to the step wise development within planetary atmospheres that can be made progressively more hostile through the introduction of extreme temperatures, radiation, wind and dust. Europlanet Research Infrastructure Facilties: Mars atmosphere simulation chambers at VUA and OU These relatively large chambers (up to 1 x 0.5 x 0.5 m) simulate Martian atmospheric conditions and the dual cooling options at VUA allows stabilised instrument temperatures while the remainder of the sample chamber can be varied between 220K and 350K. Researchers can therefore assess analytical protocols for instruments operating on Mars; e.g. effect of pCO2, temperature and material (e.g., ± ice) on spectroscopic and laser ablation techniques while monitoring the performance of detection technologies such as CCD at low T & variable p H2O & pCO2. Titan atmosphere and surface simulation chamber at OU The chamber simulates Titan's atmospheric composition under a range of

  10. The Automation of the Transonic Experimental Facility (TEF) and the Aerodynamic Experimental Facility (AEF)

    Science.gov (United States)

    2015-10-01

    Aerodynamic Experimental Facility (AEF) by Charith R Ranawake Approved for public release; distribution is unlimited...Laboratory The Automation of the Transonic Experimental Facility (TEF) and the Aerodynamic Experimental Facility (AEF) by Charith R Ranawake Weapons...To) 05/2015–08/2015 4. TITLE AND SUBTITLE The Automation of the Transonic Experimental Facility (TEF) and the Aerodynamic Experimental Facility

  11. Facility design, construction, and operation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    France has been disposing of low-level radioactive waste (LLW) at the Centre de Stockage de la Manche (CSM) since 1969 and now at the Centre de Stockage de l`Aube (CSA) since 1992. In France, several agencies and companies are involved in the development and implementation of LLW technology. The Commissariat a l`Energie Atomic (CEA), is responsible for research and development of new technologies. The Agence National pour la Gestion des Dechets Radioactifs is the agency responsible for the construction and operation of disposal facilities and for wastes acceptance for these facilities. Compagnie Generale des Matieres Nucleaires provides fuel services, including uranium enrichment, fuel fabrication, and fuel reprocessing, and is thus one generator of LLW. Societe pour les Techniques Nouvelles is an engineering company responsible for commercializing CEA waste management technology and for engineering and design support for the facilities. Numatec, Inc. is a US company representing these French companies and agencies in the US. In Task 1.1 of Numatec`s contract with Martin Marietta Energy Systems, Numatec provides details on the design, construction and operation of the LLW disposal facilities at CSM and CSA. Lessons learned from operation of CSM and incorporated into the design, construction and operating procedures at CSA are identified and discussed. The process used by the French for identification, selection, and evaluation of disposal technologies is provided. Specifically, the decisionmaking process resulting in the change in disposal facility design for the CSA versus the CSM is discussed. This report provides` all of the basic information in these areas and reflects actual experience to date.

  12. CERN n_TOF facility Performance report

    CERN Document Server

    Abbondanno, U; Cennini, P; Chiaveri, Enrico; Dario, M; Mengoni, A; Pavlopoulos, P; Saldaña, F; Vlachoudis, V; Wendler, H; CERN. Geneva; CERN. Geneva. ISOLDE and Neutron Time-of-Flight Experiments Committee; INTC

    2002-01-01

    An innovative neutron Time-of-Flight facility (n_TOF) has recently become operative at CERN. The high neutron flux is obtained by the spallation of 20 GeV/c protons onto a solid lead target. The proton beam is delivered by the Proton Synchrotron (PS) at CERN capable of providing up to four sharp bunches (RMS 6 ns) with an intensity of 7x10^12 protons per bunch within a 14.4s supercycle. The present report describes the outstanding characteristics of this facility: high neutron flux of 10^6 n/cm^2/7x10^12 p at 185 m, wide spectral function from 1 eV up to 250 MeV, low repetition rates, an excellent energy resolution of 2x10^-4 in the resonance region and low background conditions. These unique features open new possibilities for high precision neutron induced cross section measurements relevant to Nuclear Technology, Nuclear Astrophysics and fundamental Nuclear Physics.

  13. Modular Robot System for Maintenance Tasks in Large Scientific Facilities

    Directory of Open Access Journals (Sweden)

    Prithvi Sekhar Pagala

    2013-11-01

    Full Text Available Large scientific facilities such as particle accelerators are scenarios that require continuous maintenance and specific type of interventions. The intervening personnel are sometimes required to work exposed to residual radiation. The inclusion of robotic systems into these environmental conditions are being encouraged to increase the availability of the facility and reduce personal radiation doses. However, this scenario presents challenging conditions for robotic systems in terms of structural, equipment and environmental conditions. This paper addresses the design of a modular robotic system as an alternative to conventional robots to overcome the challenges. This work also explores the various capabilities of the design along with its future possibilities. The SMART heterogeneous modular robot systems, prototype and simulation results are presented.

  14. Spatial analysis to identify disparities in Philippine public school facilities

    Directory of Open Access Journals (Sweden)

    Ligaya Leah Figueroa

    2016-01-01

    Full Text Available This paper addresses the issues that affect school building conditions as a case study of the Philippines. Geographic information systems were utilized to investigate the allocation of public school resources and the extent of disparity in education facilities among 75 Philippine provinces. Four clusters of the provinces were identified by applying spatial statistics and regionalization techniques to the public school data. Overall, the building conditions are of high quality in the northern provinces. The greater region of the capital is overcrowded but well maintained. The eastern seaboard region and the southern provinces have poor conditions due to frequent natural calamities and the prolonged civil unrest, respectively. Since the spatial analysis result shows that the school building requirements are largely unmet, some recommendations are proposed so that they can be implemented by the government in order to improve the school facilities and mitigate the existing disparities among the four clusters of the Philippines.

  15. 42 CFR 494.140 - Condition: Personnel qualifications.

    Science.gov (United States)

    2010-10-01

    ... SERVICES (CONTINUED) STANDARDS AND CERTIFICATION CONDITIONS FOR COVERAGE FOR END-STAGE RENAL DISEASE... experience in clinical nutrition as a registered dietitian. (d) Standard: Social worker. The facility must...

  16. Facile solvent-free one-pot synthesis of pyranobenzopyrans and ...

    Indian Academy of Sciences (India)

    The condensation of hydroxyl coumarins in a facile one-pot procedure with active methylene esters to afford novel benzopyrans under solventless conditions is described. The products underwent further condensation and cyclization reactions to form novel heterocycles.

  17. Sub-scale Direct Connect Supersonic Combustion Facility (Research Cell 18)

    Data.gov (United States)

    Federal Laboratory Consortium — Description: RC18 is a continuous-flow, direct-connect, supersonic-combustion research facility that is capable of simulating flight conditions from Mach 3.0 to Mach...

  18. Research notes : drainage facility asset management : more than an inventory of pipes.

    Science.gov (United States)

    2007-04-01

    The primary objectives for the research project were twofold: 1) To develop and implement an Oregon-specific system for inventorying and evaluating the condition of pipes, culverts, and stormwater facilities based on the FHWA Culvert Management Syste...

  19. Safeguards in Pyroprocessing: an Integrated Model Development and Measurement Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jinsuo [The Ohio State Univ., Columbus, OH (United States). Nuclear Engineering Program, Dept. of Mechanical and Aerospace Engineering

    2017-10-01

    Pyroprocessing is an electrochemical method based on the molten salt electrolyte, mainly the LiCl-KCl eutectic molten salt, to recycle the used nuclear fuel. For a conceptual design of commercial pyroprocessing facility, tons of special nuclear materials, namely U and Pu, may be involved, which could be used for non-peaceful purposes if they are diverted. Effective safeguards approaches have to be developed prior to the development and construction of a pyroprocessing facility. Present research focused on two main objectives, namely calculating the properties of nuclear species in LiCl-KCl molten salt and developing integrated model to safeguard a pyroprocessing facility. Understanding the characteristics of special nuclear materials in LiCl-KCl eutectic salt is extremely important to understand their behaviors in an electrorefiner. The model development for the separation processes in the pyroprocessing, including electrorefining, actinide drawdown, and rare earth drawdown benefits the understanding of material transport and separation performance of these processes under various conditions. The output signals, such as potential, current, and species concentration contribute to the material balance closure and provide safeguards signatures to detect the scenarios of diversion. U and Pu are the two main elements concerned in this study due to our interest in safeguards.

  20. Sanford Underground Research Facility - The United State's Deep Underground Research Facility

    Science.gov (United States)

    Vardiman, D.

    2012-12-01

    The 2.5 km deep Sanford Underground Research Facility (SURF) is managed by the South Dakota Science and Technology Authority (SDSTA) at the former Homestake Mine site in Lead, South Dakota. The US Department of Energy currently supports the development of the facility using a phased approach for underground deployment of experiments as they obtain an advanced design stage. The geology of the Sanford Laboratory site has been studied during the 125 years of operations at the Homestake Mine and more recently as part of the preliminary geotechnical site investigations for the NSF's Deep Underground Science and Engineering Laboratory project. The overall geology at DUSEL is a well-defined stratigraphic sequence of schist and phyllites. The three major Proterozoic units encountered in the underground consist of interbedded schist, metasediments, and amphibolite schist which are crosscut by Tertiary rhyolite dikes. Preliminary geotechnical site investigations included drift mapping, borehole drilling, borehole televiewing, in-situ stress analysis, laboratory analysis of core, mapping and laser scanning of new excavations, modeling and analysis of all geotechnical information. The investigation was focused upon the determination if the proposed site rock mass could support the world's largest (66 meter diameter) deep underground excavation. While the DUSEL project has subsequently been significantly modified, these data are still available to provide a baseline of the ground conditions which may be judiciously extrapolated throughout the entire Proterozoic rock assemblage for future excavations. Recommendations for facility instrumentation and monitoring were included in the preliminary design of the DUSEL project design and include; single and multiple point extensometers, tape extensometers and convergence measurements (pins), load cells and pressure cells, smart cables, inclinometers/Tiltmeters, Piezometers, thermistors, seismographs and accelerometers, scanners (laser