WorldWideScience

Sample records for conditional transposon-based insertional

  1. The construction and preliminary analysis of a Tn5 transposon based random mutant library of baculovirus

    Institute of Scientific and Technical Information of China (English)

    Li Hui; Zhao Minglei; Yin Juan; Zhong Jiang

    2006-01-01

    A transposon-based random mutation library of AcMNPV,the type species of baculovirus,was constructed using a Tn5 transposon.The green fluorescence protein gene under the control of the Drosophila hsp70 promoter was inserted into the transposon for easy tracking in insect cells.In vitro transposition was carried out using the transposon and AcMNPV genomic DNA to allow the random insertion of the transposon into the virus genome.The transposed genome was then used to transfect Sf21 insect cells,and a library of mutant viruses capable of expressing green fluorescence protein was obtained.Two mutant viruses,B9F and Li6A were isolated,and the sites of transposon insertion were determined to be within the coding regions of the 94k and p10 genes,respectively.Both genes were determined to be nonessential in viral replication and infection.This technique will be very useful in the functional study of baculovirus genes.

  2. Jaw thrust as a predictor of insertion conditions for the proseal laryngeal mask airway.

    Science.gov (United States)

    Townsend, Russell; Brimacombe, Joseph; Keller, Christian; Wenzel, Volker; Herff, Holger

    2009-02-01

    We test the hypothesis that the response to jaw thrust is an effective predictor of insertion conditions for the ProSeal laryngeal mask airway (ProSeal LMA). One hundred and sixty patients (ASA grade 1-3, aged >18 yr) were studied. Five anesthetists blinded to the response to jaw thrust participated in the study, each performed >30 insertions. Induction of anesthesia was with propofol titrated to loss of lash reflex and apnea. A standard amount of jaw thrust was applied and any motor response noted by three observers. The ProSeal LMA was inserted using the standard digital technique. Insertion conditions were considered optimal if there was no motor or upper airway reflex response to insertion. There was no response to jaw thrust in 86% (137/160) of patients and insertion was optimal in 76% (121/160) of patients. A response to jaw thrust predicted suboptimal insertion conditions in 74% (17/23) and a lack of response predicted optimal insertion conditions in 84% (115/137). The accuracy, sensitivity and specificity were 0.82, 0.95 and 0.44, respectively. We conclude thatjaw thrust is a reliable predictor of insertion conditions for the ProSeal LMA with the digital insertion technique after induction of anesthesia with propofol. We suggest that clinicians learn how to apply the correct amount of jaw thrust and perform this test routinely.

  3. A transposon-based chromosomal engineering method to survey a large cis-regulatory landscape in mice.

    Science.gov (United States)

    Kokubu, Chikara; Horie, Kyoji; Abe, Koichiro; Ikeda, Ryuji; Mizuno, Sumi; Uno, Yoshihiro; Ogiwara, Sanae; Ohtsuka, Masato; Isotani, Ayako; Okabe, Masaru; Imai, Kenji; Takeda, Junji

    2009-08-01

    A large cis-regulatory landscape is a common feature of vertebrate genomes, particularly at key developmental gene loci with finely tuned expression patterns. Existing genetic tools for surveying large genomic regions of interest spanning over hundreds of kilobases are limited. Here we propose a chromosomal engineering strategy exploiting the local hopping trait of the Sleeping Beauty transposon in the mouse genome. We generated embryonic stem cells with a targeted integration of the transposon vector, carrying an enhancer-detecting lacZ reporter and loxP cassette, into the developmentally critical Pax1 gene locus, followed by efficient local transpositions, nested deletion formation and derivation of embryos by tetraploid complementation. Comparative reporter expression analysis among different insertion/deletion embryos substantially facilitated long-range cis-regulatory element mapping in the genomic neighborhood and demonstrated the potential of the transposon-based approach as a versatile tool for exploration of defined genomic intervals of functional or clinical relevance, such as disease-associated microdeletions.

  4. Inserting central venous catheter in emergency conditions in coagulopathic patients in comparison to noncoagulopathic patients

    Directory of Open Access Journals (Sweden)

    Mohammad Nasr-Esfahani

    2016-01-01

    Full Text Available Background: The current study was designed to compare the complications and adverse effects of central venous catheter (CVC insertion under ultrasound guidance in patients with and without coagulopathy. Materials and Methods: In this clinical trial, 59 patients who needed CVC for various reasons were enrolled. Patients were divided into two groups of those with and without coagulopathy based on complete blood count, prothrombin time, partial thromboplastin time, and international normalized ratio test results, and then, CVC was inserted with ultrasound guidance in both groups. The CVC inserting site was examined for hematoma and hemorrhage in four stages at different times. Results: There was no significant difference in the terms of demographic features, catheter lumen size (P = 0.43, and number of attempting for CVC placement (odds ratio [OR] =2.35, 95% confidence interval [CI] = 0.36–15.3, P = 0.39 between two groups. Seven out of 59 patients suffered from complications (11.9% that the complications in coagulopathic patients were oozing (5.7% and superficial hematoma (8.6% while in noncoagulopathic patients were 4.2% for both complications (OR = 0.54, 95% CI = 0.09–3.07, P = 0.767. Conclusion: According to our results, it can be concluded that inserting CVC with ultrasound guidance under emergency conditions causes no serious and life-threatening complications in coagulopathic patients.

  5. High-throughput semiquantitative analysis of insertional mutations in heterogeneous tumors

    NARCIS (Netherlands)

    Koudijs, M.J.; Klijn, C.; van der Weyden, L.; Kool, J.; ten Hoeve, J.; Sie, D.; Prasetyanti, P.R.; Schut, E.; Kas, S.; Whipp, T.; Cuppen, E.; Wessels, L.; Adams, D.J.; Jonkers, J.

    2011-01-01

    Retroviral and transposon-based insertional mutagenesis (IM) screens are widely used for cancer gene discovery in mice. Exploiting the full potential of IM screens requires methods for high-throughput sequencing and mapping of transposon and retroviral insertion sites. Current protocols are based on

  6. Measurement of impulse peak insertion loss for four hearing protection devices in field conditions.

    Science.gov (United States)

    Murphy, William J; Flamme, Gregory A; Meinke, Deanna K; Sondergaard, Jacob; Finan, Donald S; Lankford, James E; Khan, Amir; Vernon, Julia; Stewart, Michael

    2012-02-01

    In 2009, the U.S. Environmental Protection Agency (EPA) proposed an impulse noise reduction rating (NRR) for hearing protection devices based upon the impulse peak insertion loss (IPIL) methods in the ANSI S12.42-2010 standard. This study tests the ANSI S12.42 methods with a range of hearing protection devices measured in field conditions. The method utilizes an acoustic test fixture and three ranges for impulse levels: 130-134, 148-152, and 166-170 dB peak SPL. For this study, four different models of hearing protectors were tested: Bilsom 707 Impact II electronic earmuff, E·A·R Pod Express, E·A·R Combat Arms version 4, and the Etymotic Research, Inc. Electronic BlastPLG™ EB1. Five samples of each protector were fitted on the fixture or inserted in the fixture's ear canal five times for each impulse level. Impulses were generated by a 0.223 caliber rifle. The average IPILs increased with peak pressure and ranged between 20 and 38 dB. For some protectors, significant differences were observed across protector examples of the same model, and across insertions. The EPA's proposed methods provide consistent and reproducible results. The proposed impulse NRR rating should utilize the minimum and maximum protection percentiles as determined by the ANSI S12.42-2010 methods.

  7. Feasibility and speed of insertion of seven supraglottic airway devices under simulated airway conditions

    National Research Council Canada - National Science Library

    Robak, Oliver; Leonardelli, Marco; Zedtwitz-Liebenstein, Konstantin; Rützler, Kurt; Schuster, Ernst; Vaida, Sonia; Salem, Ramez; Frass, Michael

    2012-01-01

    .... The main goals of our study were to evaluate the success rate and speed of insertion of different supraglottic airway devices and to determine whether the devices could be properly inserted under...

  8. Intronic T-DNA insertion in Arabidopsis NBR1 conditionally affects wild-type transcript level

    OpenAIRE

    Rodríguez, Milagros Collados; Wawrzyńska, Anna; Sirko, Agnieszka

    2014-01-01

    Abstract The SALK_135513 line of Arabidopsis thaliana is annotated by GenBank to have the T-DNA insertion in the fourth exon of NBR1 (At4g24690). Careful molecular analyses of the homozygous plants of SALK_135513 line indicated the place of T-DNA insertion in the fourth intron. Unexpectedly, 2 kinds of NBR1 transcripts, the wild-type and the mutated, resulting from alternative splicing events, were detected in those plants. Our findings explain the problems encountered by us with phenotypic e...

  9. Heat transfer characteristics of Al2O3/water nanofluid in laminar flow conditions with circular ring insert

    Directory of Open Access Journals (Sweden)

    Mala Dharmalingam

    2016-01-01

    Full Text Available In this experimental investigation convective heat transfer, friction factor, and thermal enhancement characteristics of straight circular duct fitted with circular ring insert of constant heat flux boundary condition under fully developed laminar flow is presented. Tests have been conducted by using 0.1% volume concentration of Al2O3 nanofluid and water. Inserts of different pitch to diameter ratios of 6.25, 8.33, 12.5, and 16.67 with center core rod were used for this investigation. The circular ring insert shows a superior thermal performance than plain tube. The experimental results demonstrated that the Nusselt number, friction factor, and thermal enhancement factor increases with decrease in pitch to diameter ratio. The circular ring inserts of lower pitch to diameter ratio of 6.25 with nanofluid increases the Nusselt number by 165.38% compared to pure water and the friction factor, found to be 7.89 times higher than that of water. Empirical correlations are develope for Nusselt number and friction factor in terms of Reynolds number, volume concentration, and pitch ratio. The thermal performance factor was found to be greater than unity for all pitch to diameter ratios.

  10. A Transposon-based Analysis Reveals RASA1 Is Involved in Triple-Negative Breast Cancer.

    Science.gov (United States)

    Suárez-Cabrera, Cristian; Quintana, Rita M; Bravo, Ana; Casanova, M Llanos; Page, Angustias; Alameda, Josefa P; Paramio, Jesús M; Maroto, Alicia; Salamanca, Javier; Dupuy, Adam J; Ramírez, Angel; Navarro, Manuel

    2017-03-15

    RAS genes are mutated in 20% of human tumors, but these mutations are very rare in breast cancer. Here, we used a mouse model to generate tumors upon activation of a mutagenic T2Onc2 transposon via expression of a transposase driven by the keratin K5 promoter in a p53(+/-) background. These animals mainly developed mammary tumors, most of which had transposon insertions in one of two RASGAP genes, neurofibromin1 (Nf1) and RAS p21 protein activator (Rasa1). Immunohistochemical analysis of a collection of human breast tumors confirmed that low expression of RASA1 is frequent in basal (triple-negative) and estrogen receptor negative tumors. Bioinformatic analysis of human breast tumors in The Cancer Genome Atlas database showed that although RASA1 mutations are rare, allelic loss is frequent, particularly in basal tumors (80%) and in association with TP53 mutation. Inactivation of RASA1 in MCF10A cells resulted in the appearance of a malignant phenotype in the context of mutated p53. Our results suggest that alterations in the Ras pathway due to the loss of negative regulators of RAS may be a common event in basal breast cancer. Cancer Res; 77(6); 1357-68. ©2017 AACR.

  11. Effects of addition of ketamine, fentanyl and saline with Propofol induction on hemodynamics and laryngeal mask airway insertion conditions in oral clonidine premedicated children

    Directory of Open Access Journals (Sweden)

    Tanmoy Ghatak

    2012-01-01

    Full Text Available Background: The aim of this double-blind, prospective, randomized, controlled study was to compare the effect of addition of ketamine; fentanyl and saline with propofol anesthesia on hemodynamic profile and laryngeal mask airway (LMA insertion conditions in oral clonidine premedicated children. Methods: 180 children (age 2 - 10 years were at first given oral clonidine (4 μg/kg 90 minutes before operation, and then were randomly allocated to receive either ketamine 0.5 mg/kg (n=60, fentanyl 1 μg/kg (n=60 or 0.9% normal saline (n=60 before induction with propofol 3.0 mg/kg. Insertion of LMA was performed within 1 minute of injection of propofol. Heart rate and mean blood pressure were noted 1 min before induction (baseline, immediately after induction, before and after insertion of LMA for up to 3 min. Following LMA insertion, 6 subjective end points were noted-mouth opening, coughing, swallowing, patient′s movement, laryngospasm, and ease of an insertion. LMA insertion summed score was prepared depending upon these variables. Results: LMA insertion summed score was nearly similar in ketamine and fentanyl group, which were significantly better than saline group (P120 secs. was higher in fentanyl group compared to ketamine and saline group. Conclusion: Even in oral clonidine premedicated children, addition of ketamine with propofol provides hemodynamic stability and comparable conditions for LMA insertion like fentanyl propofol with significantly less prolonged apnea.

  12. Easi-CRISPR: a robust method for one-step generation of mice carrying conditional and insertion alleles using long ssDNA donors and CRISPR ribonucleoproteins.

    Science.gov (United States)

    Quadros, Rolen M; Miura, Hiromi; Harms, Donald W; Akatsuka, Hisako; Sato, Takehito; Aida, Tomomi; Redder, Ronald; Richardson, Guy P; Inagaki, Yutaka; Sakai, Daisuke; Buckley, Shannon M; Seshacharyulu, Parthasarathy; Batra, Surinder K; Behlke, Mark A; Zeiner, Sarah A; Jacobi, Ashley M; Izu, Yayoi; Thoreson, Wallace B; Urness, Lisa D; Mansour, Suzanne L; Ohtsuka, Masato; Gurumurthy, Channabasavaiah B

    2017-05-17

    Conditional knockout mice and transgenic mice expressing recombinases, reporters, and inducible transcriptional activators are key for many genetic studies and comprise over 90% of mouse models created. Conditional knockout mice are generated using labor-intensive methods of homologous recombination in embryonic stem cells and are available for only ~25% of all mouse genes. Transgenic mice generated by random genomic insertion approaches pose problems of unreliable expression, and thus there is a need for targeted-insertion models. Although CRISPR-based strategies were reported to create conditional and targeted-insertion alleles via one-step delivery of targeting components directly to zygotes, these strategies are quite inefficient. Here we describe Easi-CRISPR (Efficient additions with ssDNA inserts-CRISPR), a targeting strategy in which long single-stranded DNA donors are injected with pre-assembled crRNA + tracrRNA + Cas9 ribonucleoprotein (ctRNP) complexes into mouse zygotes. We show for over a dozen loci that Easi-CRISPR generates correctly targeted conditional and insertion alleles in 8.5-100% of the resulting live offspring. Easi-CRISPR solves the major problem of animal genome engineering, namely the inefficiency of targeted DNA cassette insertion. The approach is robust, succeeding for all tested loci. It is versatile, generating both conditional and targeted insertion alleles. Finally, it is highly efficient, as treating an average of only 50 zygotes is sufficient to produce a correctly targeted allele in up to 100% of live offspring. Thus, Easi-CRISPR offers a comprehensive means of building large-scale Cre-LoxP animal resources.

  13. Sleeping Beauty transposon insertional mutagenesis based mouse models for cancer gene discovery

    Science.gov (United States)

    Moriarity, Branden S; Largaespada, David A

    2016-01-01

    Large-scale genomic efforts to study human cancer, such as the cancer gene atlas (TCGA), have identified numerous cancer drivers in a wide variety of tumor types. However, there are limitations to this approach, the mutations and expression or copy number changes that are identified are not always clearly functionally relevant, and only annotated genes and genetic elements are thoroughly queried. The use of complimentary, nonbiased, functional approaches to identify drivers of cancer development and progression is ideal to maximize the rate at which cancer discoveries are achieved. One such approach that has been successful is the use of the Sleeping Beauty (SB) transposon-based mutagenesis system in mice. This system uses a conditionally expressed transposase and mutagenic transposon allele to target mutagenesis to somatic cells of a given tissue in mice to cause random mutations leading to tumor development. Analysis of tumors for transposon common insertion sites (CIS) identifies candidate cancer genes specific to that tumor type. While similar screens have been performed in mice with the PiggyBac (PB) transposon and viral approaches, we limit extensive discussion to SB. Here we discuss the basic structure of these screens, screens that have been performed, methods used to identify CIS. PMID:26051241

  14. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube

    OpenAIRE

    Murphy, William J.; Cameron J Fackler; Berger, Elliott H.; Peter B Shaw; Mike Stergar

    2015-01-01

    Impulse peak insertion loss (IPIL) was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF). Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL) were evaluated with high-level acoustic impulses created by an a...

  15. Testing of porous SiC with dense coating under relevant conditions for Flow Channel Insert application

    Energy Technology Data Exchange (ETDEWEB)

    Ordás, N., E-mail: nordas@ceit.es [CEIT and Tecnun (University of Navarra), Manuel de Lardizábal 15, 20018 San Sebastián (Spain); Bereciartu, A.; García-Rosales, C. [CEIT and Tecnun (University of Navarra), Manuel de Lardizábal 15, 20018 San Sebastián (Spain); Moroño, A.; Malo, M.; Hodgson, E.R. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain); Abellà, J.; Colominas, S. [Institut Químic de Sarrià, University Ramon Llull, Via Augusta 390, 08017 Barcelona (Spain); Sedano, L. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain)

    2014-10-15

    Highlights: • Porous SiC coated by CVD with a dense coating was developed for Flow Channel Inserts (FCI) in dual-coolant blanket concept. • Porous SiC was obtained following the sacrificial template technique, using Al{sub 2}O{sub 3} and Y{sub 2}O{sub 3} as sintering additives. • Flexural strength, thermal and electrical conductivity, and microstructure of uncoated and coated porous SiC are presented. • Adhesion of coating to porous SiC and its corrosion behavior under Pb-17.5Li at 700 °C are shown. - Abstract: Thermally and electrically insulating porous SiC ceramics are attractive candidates for Flow Channel Inserts (FCI) in dual-coolant blanket concepts thanks to its relatively inexpensive manufacturing route. To prevent tritium permeation and corrosion by Pb-15.7 a dense coating has to be applied on the porous SiC. Despite not having structural function, FCI must exhibit sufficient mechanical strength to withstand strong thermal gradients and thermo-electrical stresses during operation. This work summarizes the results on the development of coated porous SiC for FCI. Porous SiC was obtained following the sacrificial template technique, using Al{sub 2}O{sub 3} and Y{sub 2}O{sub 3} as sintering additives and a carbonaceous phase as pore former. Sintering was performed in inert gas at 1850–1950 °C during 15 min to 3 h, followed by oxidation at 650 °C to eliminate the carbonaceous phase. The most promising bulk materials were coated with a ∼30 μm thick dense SiC by CVD. Results on porosity, bending tests, thermal and electrical conductivity are presented. The microstructure of the coating, its adhesion to the porous SiC and its corrosion behavior under Pb-17.5Li are also shown.

  16. Insertion devices

    CERN Document Server

    Bahrdt, J

    2006-01-01

    The interaction of an insertion device with the electron beam in a storage ring is discussed. The radiation property including brightness, ux and polarization of an ideal and real planar and helical / elliptical device is described. The magnet design of planar, helical, quasiperiodic devices and of devices with a reduced on axis power density are resumed.

  17. Calorimeter insertion

    CERN Multimedia

    2006-01-01

    Calorimeter insertion between toroids in the ATLAS experiment detector Calorimeters are surrounding the inner detector. Calorimeters will absorb and measure the energies of the most charged and neutral particles after the collisions. The saved energy in the calorimeter is detected and converted to signals that are taken out with data taking electronics.

  18. Optimizing Cutting Conditions for Minimum Surface Roughness in Face Milling of High Strength Steel Using Carbide Inserts

    Directory of Open Access Journals (Sweden)

    Adel Taha Abbas

    2016-01-01

    Full Text Available A full factorial design technique is used to investigate the effect of machining parameters, namely, spindle speed (N, depth of cut (ap, and table feed rate (Vf, on the obtained surface roughness (Ra and Rt during face milling operation of high strength steel. A second-order regression model was built using least squares method depending on the factorial design results to approximate a mathematical relationship between the surface roughness and the studied process parameters. Analysis of variance was conducted to estimate the significance of each factor and interaction with respect to the surface roughness. For Ra, the results show that spindle speed, depth of cut, and table feed rate have a significant effect on the surface roughness in both linear and quadratic terms. There is also an interaction between depth of cut and feed rate. It also appears that feed rate has the greatest effect on the data variation followed by depth of cut. For Rt, the results show that the table feed rate is the most effective factor followed by the depth of cut, while the spindle speed had a significant small effect only in its quadratic term. The conditions of minimum Ra and Rt are identified through least square optimization. Moreover, multiobjective optimization for minimizing Ra and maximizing metal removal rate Q is conducted and the results are presented.

  19. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube

    Directory of Open Access Journals (Sweden)

    William J Murphy

    2015-01-01

    Full Text Available Impulse peak insertion loss (IPIL was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF. Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL were evaluated with high-level acoustic impulses created by an acoustic shock tube at levels of 134 decibels (dB, 150 dB, and 168 dB. The fixtures were identical except that the E-A-RCAL ISL fixture had ear canals that were 3 mm longer than the National Institute for Occupational Safety and Health (NIOSH ISL fixture. Four hearing protection conditions were tested: Combat Arms earplug with the valve open, ETYPlugs ® earplug, TacticalPro headset, and a dual-protector ETYPlugs earplug with TacticalPro earmuff. The IPILs measured for the E-A-RCAL fixture were 1.4 dB greater than the National Institute for Occupational Safety and Health (NIOSH ISL ATF. For the E-A-RCAL ISL ATF, the left ear IPIL was 2.0 dB greater than the right ear IPIL. For the NIOSH ATF, the right ear IPIL was 0.3 dB greater than the left ear IPIL.

  20. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube.

    Science.gov (United States)

    Murphy, William J; Fackler, Cameron J; Berger, Elliott H; Shaw, Peter B; Stergar, Mike

    2015-01-01

    Impulse peak insertion loss (IPIL) was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF). Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL) were evaluated with high-level acoustic impulses created by an acoustic shock tube at levels of 134 decibels (dB), 150 dB, and 168 dB. The fixtures were identical except that the E-A-RCAL ISL fixture had ear canals that were 3 mm longer than the National Institute for Occupational Safety and Health (NIOSH) ISL fixture. Four hearing protection conditions were tested: Combat Arms earplug with the valve open, ETYPlugs ® earplug, TacticalPro headset, and a dual-protector ETYPlugs earplug with TacticalPro earmuff. The IPILs measured for the E-A-RCAL fixture were 1.4 dB greater than the National Institute for Occupational Safety and Health (NIOSH) ISL ATF. For the E-A-RCAL ISL ATF, the left ear IPIL was 2.0 dB greater than the right ear IPIL. For the NIOSH ATF, the right ear IPIL was 0.3 dB greater than the left ear IPIL.

  1. Non-insertional Achilles tendinopathy

    Science.gov (United States)

    Pearce, Christopher J.; Tan, Audrey

    2016-01-01

    Non-insertional Achilles tendinopathy is a degenerative condition characterised by pain on activity. Eccentric stretching is the most effective treatment. Surgical treatment is reserved for recalcitrant cases. Minimally-invasive and tendinoscopic treatments are showing promising results. Cite this article: Pearce CJ, Tan A. Non-insertional Achilles tendinopathy. EFORT Open Rev 2016;1:383-390. DOI: 10.1302/2058-5241.1.160024. PMID:28461917

  2. Insertional mutagenesis by a hybrid piggyBac and sleeping beauty transposon in the rat.

    Science.gov (United States)

    Furushima, Kenryo; Jang, Chuan-Wei; Chen, Diane W; Xiao, Ningna; Overbeek, Paul A; Behringer, Richard R

    2012-12-01

    A hybrid piggyBac/Sleeping Beauty transposon-based insertional mutagenesis system that can be mobilized by simple breeding was established in the rat. These transposons were engineered to include gene trap sequences and a tyrosinase (Tyr) pigmentation reporter to rescue the albinism of the genetic background used in the mutagenesis strategy. Single-copy transposon insertions were transposed into the rat genome by co-injection of plasmids carrying the transposon and RNA encoding piggyBac transposase into zygotes. The levels of transgenic Tyr expression were influenced by chromosomal context, leading to transgenic rats with different pigmentation that enabled visual genotyping. Transgenic rats designed to ubiquitously express either piggyBac or Sleeping Beauty transposase were generated by standard zygote injection also on an albino background. Bigenic rats carrying single-copy transposons at known loci and transposase transgenes exhibited coat color mosaicism, indicating somatic transposition. PiggyBac or Sleeping Beauty transposase bigenic rats bred with wild-type albino rats yielded offspring with pigmentation distinct from the initial transposon insertions as a consequence of germline transposition to new loci. The germline transposition frequency for Sleeping Beauty and piggyBac was ∼10% or about one new insertion per litter. Approximately 50% of the insertions occurred in introns. Chimeric transcripts containing endogenous and gene trap sequences were identified in Gabrb1 mutant rats. This mutagenesis system based on simple crosses and visual genotyping can be used to generate a collection of single-gene mutations in the rat.

  3. Chest tube insertion

    Science.gov (United States)

    ... tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Kirsch TD, Sax J. Tube thoracostomy. In: Roberts JR, ed. Roberts and ... . 6th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap 10.

  4. Feeding tube insertion - gastrostomy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002937.htm Feeding tube insertion - gastrostomy To use the sharing features on this page, please enable JavaScript. A gastrostomy feeding tube insertion is the placement of a feeding ...

  5. A new way to rapidly create functional, fluorescent fusion proteins: random insertion of GFP with an in vitro transposition reaction

    Directory of Open Access Journals (Sweden)

    Jakobsdottir Klara B

    2002-06-01

    Full Text Available Abstract Background The jellyfish green fluorescent protein (GFP can be inserted into the middle of another protein to produce a functional, fluorescent fusion protein. Finding permissive sites for insertion, however, can be difficult. Here we describe a transposon-based approach for rapidly creating libraries of GFP fusion proteins. Results We tested our approach on the glutamate receptor subunit, GluR1, and the G protein subunit, αs. All of the in-frame GFP insertions produced a fluorescent protein, consistent with the idea that GFP will fold and form a fluorophore when inserted into virtually any domain of another protein. Some of the proteins retained their signaling function, and the random nature of the transposition process revealed permissive sites for insertion that would not have been predicted on the basis of structural or functional models of how that protein works. Conclusion This technique should greatly speed the discovery of functional fusion proteins, genetically encodable sensors, and optimized fluorescence resonance energy transfer pairs.

  6. Tie rod insertion test

    CERN Multimedia

    B. LEVESY

    2002-01-01

    The superconducting coil is inserted in the outer vaccum tank and supported by a set of tie rods. These tie rods are made of titanium alloy. This test reproduce the final insertion of the tie rods inside the outer vacuum tank.

  7. Chest tube insertion - slideshow

    Science.gov (United States)

    ... presentations/100008.htm Chest tube insertion - series—Normal anatomy To use the sharing features ... pleural space is the space between the inner and outer lining of the lung. It is normally very thin, and lined only ...

  8. Ear tube insertion - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100045.htm Ear tube insertion - series—Normal anatomy To use the ... 4 Overview The eardrum (tympanic membrane) separates the ear canal from the middle ear. Review Date 8/ ...

  9. Growth condition optimization and mobility enhancement through inserting AlAs monolayer in the InP-based InxGa1-xAs/In0.52Al0.48As HEMT structures

    Science.gov (United States)

    Zhou, Shu-Xing; Qi, Ming; Ai, Li-Kun; Xu, An-Huai

    2016-09-01

    The structure of InP-based InxGa1-xAs/In0.52Al0.48As pseudomorphic high electron mobility transistor (PHEMT) was optimized in detail. Effects of growth temperature, growth interruption time, Si δ-doping condition, channel thickness and In content, and inserted AlAs monolayer (ML) on the two-dimensional electron gas (2DEG) performance were investigated carefully. It was found that the use of the inserted AlAs monolayer has an enhancement effect on the mobility due to the reduction of interface roughness and the suppression of Si movement. With optimization of the growth parameters, the structures composed of a 10 nm thick In0.75Ga0.25As channel layer and a 3 nm thick AlAs/In0.52Al0.48As superlattices spacer layer exhibited electron mobilities as high as 12500 cm2·V-1·s-1 (300 K) and 53500 cm2·V-1·s-1 (77 K) and the corresponding sheet carrier concentrations (Ns) of 2.8 × 1012 cm-2 and 2.9 × 1012 cm-2, respectively. To the best of the authors’ knowledge, this is the highest reported room temperature mobility for InP-based HEMTs with a spacer of 3 nm to date. Project supported by the National Natural Science Foundation of China (Grant No. 61434006).

  10. Comparing Leaf and Root Insertion

    Directory of Open Access Journals (Sweden)

    Jaco Geldenhuys

    2010-07-01

    Full Text Available We consider two ways of inserting a key into a binary search tree: leaf insertion which is the standard method, and root insertion which involves additional rotations. Although the respective cost of constructing leaf and root insertion binary search trees trees, in terms of comparisons, are the same in the average case, we show that in the worst case the construction of a root insertion binary search tree needs approximately 50% of the number of comparisons required by leaf insertion.

  11. One-step generation of mice carrying a conditional allele together with an HA-tag insertion for the delta opioid receptor

    Science.gov (United States)

    Su, Dongru; Wang, Min; Ye, Chenli; Fang, Jiahui; Duan, Yanhui; Zhang, Zhenghong; Hua, Qiuhong; Shi, Changjie; Zhang, Lihong; Zhang, Ru; Xie, Xin

    2017-01-01

    G protein-coupled receptors (GPCRs) are important modulators of many physiological functions and excellent drug targets for many diseases. However, to study the functions of endogenous GPCRs is still a challenging task, partially due to the low expression level of GPCRs and the lack of highly potent and selective GPCR antibodies. Overexpression or knock-in of tagged GPCRs, or knockout of specific GPCRs in mice, are common strategies used to study the in vivo functions of these receptors. However, generating separate mice carrying tagged GPCRs or conditional alleles for GPCRs is labor intensive, and requires additional breeding costs. Here we report the generation of mice carrying an HA-tagged DOR (delta opioid receptor) flanked by LoxP sequences at the endogenous DOR locus using a single recombination step, aided by the TALEN system. These animals can be used directly to study the expression, localization, protein-protein interaction and signal transduction of endogenous DOR using anti-HA antibodies. By crossing with mice expressing tissue-specific Cre, these mice can also generate offspring with DOR knockout within specific tissues. These mice are powerful tools to study the in vivo functions of DOR. Furthermore, the gene modification strategy could also be used to study the functions of many other GPCRs. PMID:28300205

  12. Pixel detector insertion

    CERN Multimedia

    CMS

    2015-01-01

    Insertion of the Pixel Tracker, the 66-million-channel device used to pinpoint the vertex of each colliding proton pair, located at the heart of the detector. The geometry of CMS is a cylinder lying on its side (22 meters long and 15 meters high in dia

  13. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    The specific energy obtainable by discharge of porous insertion electrodes is limited by electrolyte depletion in thepores. This can be overcome using a solid ion conductor as electrolyte. The term "composite" is used to distinguishthese electrodes from porous electrodes with liquid electrolyte...

  14. Inserting the CMS solenoid

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    The huge superconducting solenoid for CMS is inserted into the cryostat barrel. CMS uses the world's largest thin solenoid, in terms of energy stored, and is 12 m long, with a diameter of 6 m and weighing 220 tonnes. When turned on the magnet will produce a field strength of 4 T using superconducting niobium-titanium material at 4.5 K.

  15. High Speed Video Insertion

    Science.gov (United States)

    Janess, Don C.

    1984-11-01

    This paper describes a means of inserting alphanumeric characters and graphics into a high speed video signal and locking that signal to an IRIG B time code. A model V-91 IRIG processor, developed by Instrumentation Technology Systems under contract to Instrumentation Marketing Corporation has been designed to operate in conjunction with the NAC model FHS-200 High Speed Video Camera which operates at 200 fields per second. The system provides for synchronizing the vertical and horizontal drive signals such that the vertical sync precisely coincides with five millisecond transitions in the IRIG time code. Additionally, the unit allows for the insertion of an IRIG time message as well as other data and symbols.

  16. ENDOSCOPIC GROMMET INSERTION OUR EXPERIENCE

    Directory of Open Access Journals (Sweden)

    Balasubramanian Thiagarajan

    2012-03-01

    Full Text Available Grommet insertion the commonest surgical procedure next only to circumcision is usually performed using an operating microscope 1. Authors have been using 4 mm 0 degree nasalendoscopes to perform this procedure during the last 5 years. This is a report of their experience in using endoscope inlieu of microscope in performing this surgery. This study makes a comparative analysis of Endoscopic Grommet insertion viz a viz Microscopic Grommet insertion. For this comparative analysis one year (2009 data base of Government Stanley Medical College Chennai India was used. This study reveals that Endoscopic Grommet insertion compared favorably with Microscopic Grommet insertion in all aspects with certain obvious advantages.

  17. Conditional gene expression in the mouse using a Sleeping Beauty gene-trap transposon

    Directory of Open Access Journals (Sweden)

    Hackett Perry B

    2006-06-01

    Full Text Available Abstract Background Insertional mutagenesis techniques with transposable elements have been popular among geneticists studying model organisms from E. coli to Drosophila and, more recently, the mouse. One such element is the Sleeping Beauty (SB transposon that has been shown in several studies to be an effective insertional mutagen in the mouse germline. SB transposon vector studies have employed different functional elements and reporter molecules to disrupt and report the expression of endogenous mouse genes. We sought to generate a transposon system that would be capable of reporting the expression pattern of a mouse gene while allowing for conditional expression of a gene of interest in a tissue- or temporal-specific pattern. Results Here we report the systematic development and testing of a transposon-based gene-trap system incorporating the doxycycline-repressible Tet-Off (tTA system that is capable of activating the expression of genes under control of a Tet response element (TRE promoter. We demonstrate that the gene trap system is fully functional in vitro by introducing the "gene-trap tTA" vector into human cells by transposition and identifying clones that activate expression of a TRE-luciferase transgene in a doxycycline-dependent manner. In transgenic mice, we mobilize gene-trap tTA vectors, discover parameters that can affect germline mobilization rates, and identify candidate gene insertions to demonstrate the in vivo functionality of the vector system. We further demonstrate that the gene-trap can act as a reporter of endogenous gene expression and it can be coupled with bioluminescent imaging to identify genes with tissue-specific expression patterns. Conclusion Akin to the GAL4/UAS system used in the fly, we have made progress developing a tool for mutating and revealing the expression of mouse genes by generating the tTA transactivator in the presence of a secondary TRE-regulated reporter molecule. A vector like the gene

  18. Prenatal diagnosis of abnormal umbilical cord insertion: a rare case of furcate insertion.

    Science.gov (United States)

    Fujita, Yasuyuki; Yumoto, Yasuo; Kato, Kiyoko

    2017-04-01

    Furcate insertion (FI) is an extremely rare abnormality of umbilical cord insertion. One of the complications associated with FI is hemorrhage from the umbilical vein at the site of FI of the umbilical cord, which can cause sudden intrauterine fetal death. Because of its rarity, no prenatal diagnosis of FI has been reported. A 31-year-old woman at 34 weeks' gestation was referred to us for suspected abnormal cord insertion. Ultrasonography showed normal fetal growth and amniotic fluid volume, with no fetal anomalies. Although the umbilical cord contained three vessels inserted at the center of the placenta, the umbilical vessels separated from the cord substance before their insertion to the placenta. Based on these findings, the patient was diagnosed with FI. During labor at 37 weeks' gestation, fetal heart rate was normal and a healthy neonate was delivered. At macroscopic examination, the umbilical cord was inserted in the middle of the placenta, and the placental parenchymal tissue just under the cord insertion was deficient and had been changed to white, elastic hard tissue. Pathological examination of the white tissue revealed fibrin deposition and focal infarction. Although FI is a very rare condition, prenatal diagnosis can be achieved through detailed color Doppler ultrasound studies. Therefore, taking precautions and keeping in mind the poor fetal outcome associated with FI are preferred.

  19. Facility target insert shielding assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-06

    Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In the present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.

  20. Impedance calculation for ferrite inserts

    Energy Technology Data Exchange (ETDEWEB)

    Breitzmann, S.C.; Lee, S.Y.; /Indiana U.; Ng, K.Y.; /Fermilab

    2005-01-01

    Passive ferrite inserts were used to compensate the space charge impedance in high intensity space charge dominated accelerators. They study the narrowband longitudinal impedance of these ferrite inserts. they find that the shunt impedance and the quality factor for ferrite inserts are inversely proportional to the imaginary part of the permeability of ferrite materials. They also provide a recipe for attaining a truly passive space charge impedance compensation and avoiding narrowband microwave instabilities.

  1. A single-center experience of 2153 tunneled-cuffed catheter insertions radiologically placed via the internal jugular vein: An evaluation of technical success and complication rates relative to underlying disease conditions

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan; Yim, Nm Yeol; Kim, Yong Tae; Noh, Hoon; Ki, So Yeon; Kim Jae Kyu; Kim, Hyoung Ook; Chang, Nam Kyu [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2015-01-15

    To evaluate the technical success and complication rates of tunneled-cuffed catheter insertions radiologically placed via the internal jugular vein in patients with different types of underlying diseases. A total of 2153 tunneled-cuffed catheter insertions performed in 1926 patients between January 2008 and December 2012 were retrospectively reviewed. All procedures were conducted using sonography and fluoroscopy. The number of catheter maintenance days, technical success rates, and complication rates were analyzed based on radiologic and medical records. A total of 204809 catheter maintenance days (mean, 95.35 days; range, 0-1710 days) were recorded. Technical success was achieved in 2148 insertions (99.77%). A total of 185 complications (8.61%, 0.903/1000 catheter days) were observed, including 22 procedure-related complications (1.02%). A total of 143 catheters (6.66%) were removed due to complications. Significant differences in complication rates were observed between patients with or without underlying hematologic diseases (11.65% vs. 7.02%, respectively; p = 0.000). Significant differences in catheter thrombosis were observed between patients in which right-sided or left-sided venous approaches were used (0.81% vs. 2.70%, respectively; p = 0.010). The very high technical success rates and very low procedure-related complication rates indicate insertion of a tunneled-cuffed catheter radiologically placed via the internal jugular vein is safe and effective.

  2. Insertion device and method for accurate and repeatable target insertion

    Energy Technology Data Exchange (ETDEWEB)

    Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.; Dillon-Townes, Lawrence; Neil, George R.

    2017-07-04

    The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.

  3. Transposon insertion mapping with PIMMS – Pragmatic Insertional Mutation Mapping System.

    Directory of Open Access Journals (Sweden)

    Adam eBlanchard

    2015-04-01

    Full Text Available The PIMMS (Pragmatic Insertional Mutation Mapping System pipeline has been developed for simple conditionally essential genome discovery experiments in bacteria. Capable of using raw sequence data files alongside a FASTA sequence of the reference genome and GFF file, PIMMS will generate a tabulated output of each coding sequence with corresponding mapped insertions accompanied with normalised results enabling streamlined analysis. This allows for a quick assay of the genome to identify conditionally essential genes on a standard desktop computer prioritising results for further investigation.Availability: The PIMMS script, manual and accompanying test data is freely available at https://github.com/ADAC-UoN/PIMMS

  4. Lithium insertion in nanostructured titanates

    NARCIS (Netherlands)

    Borghols, W.J.H.

    2010-01-01

    Upon nano-sizing of insertion compounds several significant changes in Li-insertion behavior have been observed for sizes below approximately 50 nm. Although the origins of the phenomena are interrelated, the changes can be divided in three main observations. (1) The formation of new phases, leading

  5. conditions

    Directory of Open Access Journals (Sweden)

    M. Venkatesulu

    1996-01-01

    Full Text Available Solutions of initial value problems associated with a pair of ordinary differential systems (L1,L2 defined on two adjacent intervals I1 and I2 and satisfying certain interface-spatial conditions at the common end (interface point are studied.

  6. Gas turbine vane cooling air insert

    Energy Technology Data Exchange (ETDEWEB)

    North, W.E.; Hultgren, K.G.; Dishman, C.D.; Van Heusden, G.S.

    1992-09-08

    This patent describes a gas turbine. It comprises turbine vanes, each of the vanes supplied with cooling air and having: an airfoil portion forming a first cavity having an insert disposed therein for directing the flow of the cooling air, the insert having first and second insert ends; a shroud portion from which the airfoil portion extends, the insert attached to the shroud portion at the first insert end; an insert extension extending through a portion of the insert and extending beyond the first insert end, the insert extension and the insert forming an annular gap therebetween separating the insert from the insert extension; a plate covering at least a portion of the shroud, the plate having a first hole formed therein through which the insert extension extends; and at least a first seal extending between the insert extension and the insert, and sealing the annular gap therebetween. This patent also describes a method of making a gas turbine. It comprises welding a first tubular insert adjacent its first end to a vane outer shroud; partially inserting a second tubular insert into the first tubular member and attaching the second tubular insert thereto; placing a plate having a hole formed therein on the outer shroud so that the hole surrounds the second tubular insert; and attaching the second tubular insert to the plate by placing a first seal between the first and second tubular inserts and attaching the first seal to each of the first and second tubular inserts, and placing a second seal between the second tubular insert and the plate and welding the second seal to the second tubular insert and the plate.

  7. Central Solenoid Insert Technical Specification

    Energy Technology Data Exchange (ETDEWEB)

    Martovetsky, Nicolai N [ORNL; Smirnov, Alexandre [ORNL

    2011-09-01

    The US ITER Project Office (USIPO) is responsible for the ITER central solenoid (CS) contribution to the ITER project. The Central Solenoid Insert (CSI) project will allow ITER validation the appropriate lengths of the conductors to be used in the full-scale CS coils under relevant conditions. The ITER Program plans to build and test a CSI to verify the performance of the CS conductor. The CSI is a one-layer solenoid with an inner diameter of 1.48 m and a height of 4.45 m between electric terminal ends. The coil weight with the terminals is approximately 820 kg without insulation. The major goal of the CSI is to measure the temperature margin of the CS under the ITER direct current (DC) operating conditions, including determining sensitivity to load cycles. Performance of the joints, ramp rate sensitivity, and stability against thermal or electromagnetic disturbances, electrical insulation, losses, and instrumentation are addressed separately and therefore are not major goals in this project. However, losses and joint performance will be tested during the CSI testing campaign. The USIPO will build the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at the Japan Atomic Energy Agency (JAEA), Naka, Japan. The industrial vendors (the Suppliers) will report to the USIPO (the Company). All approvals to proceed will be issued by the Company, which in some cases, as specified in this document, will also require the approval of the ITER Organization. Responsibilities and obligations will be covered by respective contracts between the USIPO, called Company interchangeably, and the industrial Prime Contractors, called Suppliers. Different stages of work may be performed by more than one Prime Contractor, as described in this specification. Technical requirements of the contract between the Company and the Prime Contractor will be covered by the Fabrication Specifications developed by the Prime Contractor based on this document and approved by

  8. Post-CTS Delay Insertion

    Directory of Open Access Journals (Sweden)

    Jianchao Lu

    2010-01-01

    clock skew operation is performed only at the clock sinks in order to preserve the structure and the optimizations implemented in the clock tree synthesis stage. The methodology is implemented as a linear programming model amenable to two design objectives: fixing timing violations or optimizing the clock period. Experimental results show that the clock networks of the largest ISCAS'89 circuits can be corrected post-CTS to resolve the timing conflicts in approximately 90% of the circuits with minimal delay insertion (0.159  ×  clock period per clock path on average. It is also shown that the majority of the clock period improvement achievable through unrestricted clock skew scheduling are obtained through very limited insertion (≈43% average improvement through 10% of max insertion.

  9. Gene Insertion Patterns and Sites

    Science.gov (United States)

    Vain, Philippe; Thole, Vera

    During the past 25 years, the molecular analysis of transgene insertion patterns and sites in plants has greatly contributed to our understanding of the mechanisms underlying transgene integration, expression, and stability in the nuclear genome. Molecular characterization is also an essential step in the safety assessment of genetically modified crops. This chapter describes the standard experimental procedures used to analyze transgene insertion patterns and loci in cereals and grasses transformed using Agrobacterium tumefaciens or direct transfer of DNA. Methods and protocols enabling the determination of the number and configuration of transgenic loci via a combination of inheritance studies, polymerase chain reaction, and Southern analyses are presented. The complete characterization of transgenic inserts in plants is, however, a holistic process relying on a wide variety of experimental approaches. In this chapter, these additional approaches are not detailed but references to relevant bibliographic records are provided.

  10. Mechanism for electrochemical hydrogen insertion in carbonaceous materials

    Science.gov (United States)

    Qu, Deyang

    The mechanism for safe and reversible storage of hydrogen in porous carbonaceous materials by electrochemical decomposition of water in alkaline electrolyte is proposed. Atomic H was found to be inserted into the microdomains of defective graphene layers. Hydrogen storage capacity increases with increasing interlayer distance between carbon sheets. Hydrogen insertion in carbonaceous materials occurs at ambient conditions. Static potential acts as an electrochemical valve which can retain the hydrogen in the carbon structure, thus preventing leakage during storage.

  11. An insertion algorithm for catabolizability

    CERN Document Server

    Blasiak, Jonah

    2009-01-01

    Motivated by our recent work relating canonical bases to combinatorics of Garsia-Procesi modules \\cite{B}, we give an insertion algorithm that computes the catabolizability of the insertion tableau of a standard word. This allows us to characterize catabolizability as the statistic on words invariant under Knuth transformations, certain (co)rotations, and a new operation called a catabolism transformation. We also prove a Greene's Theorem-like characterization of catabolizability, and a result about how cocyclage changes catabolizability, strengthening a similar result in \\cite{SW}.

  12. Concepts for stereoselective acrylate insertion

    KAUST Repository

    Neuwald, Boris

    2013-01-23

    Various phosphinesulfonato ligands and the corresponding palladium complexes [{((PaO)PdMeCl)-μ-M}n] ([{( X1-Cl)-μ-M}n], (PaO) = κ2- P,O-Ar2PC6H4SO2O) with symmetric (Ar = 2-MeOC6H4, 2-CF3C6H4, 2,6-(MeO)2C6H3, 2,6-(iPrO)2C 6H3, 2-(2′,6′-(MeO)2C 6H3)C6H4) and asymmetric substituted phosphorus atoms (Ar1 = 2,6-(MeO)2C6H 3, Ar2 = 2′-(2,6-(MeO)2C 6H3)C6H4; Ar1 = 2,6-(MeO)2C6H3, Ar2 = 2-cHexOC 6H4) were synthesized. Analyses of molecular motions and dynamics by variable temperature NMR studies and line shape analysis were performed for the free ligands and the complexes. The highest barriers of ΔGa = 44-64 kJ/mol were assigned to an aryl rotation process, and the flexibility of the ligand framework was found to be a key obstacle to a more effective stereocontrol. An increase of steric bulk at the aryl substituents raises the motional barriers but diminishes insertion rates and regioselectivity. The stereoselectivity of the first and the second methyl acrylate (MA) insertion into the Pd-Me bond of in situ generated complexes X1 was investigated by NMR and DFT methods. The substitution pattern of the ligand clearly affects the first MA insertion, resulting in a stereoselectivity of up to 6:1 for complexes with an asymmetric substituted phosphorus. In the consecutive insertion, the stereoselectivity is diminished in all cases. DFT analysis of the corresponding insertion transition states revealed that a selectivity for the first insertion with asymmetric (P aO) complexes is diminished in the consecutive insertions due to uncooperatively working enantiomorphic and chain end stereocontrol. From these observations, further concepts are developed. © 2012 American Chemical Society.

  13. Insertion device calculations with mathematica

    Energy Technology Data Exchange (ETDEWEB)

    Carr, R. [Stanford Synchrotron Radiation Lab., CA (United States); Lidia, S. [Univ. of California, Davis, CA (United States)

    1995-02-01

    The design of accelerator insertion devices such as wigglers and undulators has usually been aided by numerical modeling on digital computers, using code in high level languages like Fortran. In the present era, there are higher level programming environments like IDL{reg_sign}, MatLab{reg_sign}, and Mathematica{reg_sign} in which these calculations may be performed by writing much less code, and in which standard mathematical techniques are very easily used. The authors present a suite of standard insertion device modeling routines in Mathematica to illustrate the new techniques. These routines include a simple way to generate magnetic fields using blocks of CSEM materials, trajectory solutions from the Lorentz force equations for given magnetic fields, Bessel function calculations of radiation for wigglers and undulators and general radiation calculations for undulators.

  14. The first LHC insertion quadrupole

    CERN Multimedia

    2004-01-01

    An important milestone was reached in December 2003 at the CERN Magnet Assembly Facility. The team from the Accelerator Technology - Magnet and Electrical Systems group, AT-MEL, completed the first special superconducting quadrupole for the LHC insertions which house the experiments and major collider systems. The magnet is 8 metres long and contains two matching quadrupole magnets and an orbit corrector, a dipole magnet, used to correct errors in quadrupole alignment. All were tested in liquid helium and reached the ultimate performance criteria required for the LHC. After insertion in the cryostat, the superconducting magnet will be installed as the Q9 quadrupole in sector 7-8, the first sector of the LHC to be put in place in 2004. Members of the quadrupole team, from the AT-MEL group, gathered around the Q9 quadrupole at its inauguration on 12 December 2003 in building 181.

  15. Inserting Agility in System Development

    Science.gov (United States)

    2012-07-01

    Agile IT Acquisition, IT Box, Scrum Inserting Agility in System Development Matthew R. Kennedy and Lt Col Dan Ward, USAF With the fast-paced nature...1,700 individuals and 71 countries, found Scrum and eXtreme Programming to be the most widely followed method- ologies (VersionOne, 2007). Other...University http://www.dau.mil 259 Defense ARJ, July 2012, Vol. 19 No. 3 : 249–264 Scrum Scrum is a framework used for project management, which is

  16. HTS Insert Magnet Design Study

    CERN Document Server

    Devaux, M; Fleiter, J; Fazilleau, P; Lécrevisse, T; Pes, C; Rey, J-M; Rifflet, J-M; Sorbi, M; Stenvall, A; Tixador, P; Volpini, G

    2011-01-01

    Future accelerator magnets will need to reach higher field in the range of 20 T. This field level is very difficult to reach using only Low Temperature Superconductor materials whereas High Temperature Superconductors (HTS) provide interesting opportunities. High current densities and stress levels are needed to design such magnets. YBCO superconductor indeed carries large current densities under high magnetic field and provides good mechanical properties especially when produced using the IBAD approach. The HFM EUCARD program studies the design and the realization of an HTS insert of 6 T inside a Nb3Sn dipole of 13T at 4.2 K. In the2HTS insert, engineering current densities higher than 250 MA/m under 19 T are required to fulfill the specifications. The stress level is also very severe. YBCO IBAD tapes theoretically meet these challenges from presented measurements. The insert protection is also a critical because HTS materials show low quench propagation velocities and the coupling with the Nb3Sn magnet make...

  17. Field errors in hybrid insertion devices

    Energy Technology Data Exchange (ETDEWEB)

    Schlueter, R.D. [Lawrence Berkeley Lab., CA (United States)

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed.

  18. JT/LJT connector insert material evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Baca, J.R.F.

    1991-10-01

    Different insert (insulator) materials are undergoing evaluation to replace the Fiberite E-3938 BE96 material currently used. Also being evaluated is the reconfiguration of the insert and metal shell-edge geometries for the purpose of reducing the alleged interference principally responsible for insert damage.

  19. THEORETICAL ANALYSIS ON THE DEPTH OF NEEDLE-INSERTION

    Institute of Scientific and Technical Information of China (English)

    LIN Wen-jian

    2005-01-01

    In the present paper, the author sums up and analyzes descriptions about needle-insertion depth in Chinese classical medical book Huang Di Nei Jing (The Yellow Emperor's Internal Classic). In many chapters of Nei Jing, the needle-insertion depth is stressed to be various according to 1) the deficiency or excess of syndromes, 2) the patients' constitution, 3) the severity of disease, 4) the duration of disease, 5) the location of disease, 6) the patient's age, 7) the location of the needled acupoint, 8) the season, 9) the patient's temperament, 10) the pulse condition, 11) the state of "Deqi", and 12) the location of the running course of meridians. In addition, different kinds of diseases and different stages of diseases also need different depths of needle insertion, different manipulating skills and different stimulating quantity.

  20. Sequential cooling insert for turbine stator vane

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Russel B

    2017-04-04

    A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.

  1. Analysis of C60 insertion into single wall carbon nanotube by molecular dynamics simulation

    Science.gov (United States)

    Ishii, Takafumi; Esfarjani, Keivan; Hashi, Yuichi; Kawazoe, Yoshiyuki; Iijima, Sumio

    2001-10-01

    Classical molecular dynamics is used to simulate the insertion of C60 into a (10, 10) single wall nano tube (SWNT). We propose that the insertion process occurs through the open end of the tube. After insertion, the energy exchange between the C60 and the nanotube causes the kinetic energy of the former to decrease as it moves inside the tube. This kinetic energy loss is due to a "friction force" which we calculated for several insertion conditions. The binding energy of the C60 with the SWNT is due to Van der Waals interaction, and is found to be about 3.5 eV.

  2. Teleoperated master-slave needle insertion.

    Science.gov (United States)

    Abolhassani, Niki; Patel, Rajni V

    2009-12-01

    Accuracy of needle tip placement and needle tracking in soft tissue are of particular importance in many medical procedures. In recent years, developing autonomous and teleoperated systems for needle insertion has become an active area of research. In this study, needle insertion was performed using a master-slave set-up with multi-degrees of freedom. The effect of force feedback on the accuracy of needle insertion was investigated. In addition, this study compared autonomous, teleoperated and semi-autonomous needle insertion. The results of this study show that incorporation of force feedback can improve teleoperated needle insertion. However, autonomous and semi-autonomous needle insertions, which use feedback from a deflection model, provide significantly better performance. Development of a haptic master-slave needle insertion system, which is capable of performing some autonomous tasks based on feedback from tissue deformation and needle deflection models, can improve the performance of autonomous robotics-based insertions as well as non-autonomous teleoperated manual insertions. Copyright (c) 2009 John Wiley & Sons, Ltd.

  3. A HTS dipole insert coil constructed

    CERN Document Server

    Ballarino, A; Rey, J M; Stenvall, A; Sorbi, M; Tixador, P

    2013-01-01

    This report is the deliverable report 7.4.1 “A HTS dipole insert coil constructed“. The report has three parts: “Design report for the HTS dipole insert”, “One insert pancake prototype coil constructed with the setup for a high field test”, and “All insert components ordered”. The three report parts show that, although the insert construction will be only completed by end 2013, all elements are present for a successful completion and that, given the important investments done by the participants, there is a full commitment of all of them to finish the project

  4. Multipurpose Transposon-Insertion Libraries in Yeast.

    Science.gov (United States)

    Kumar, Anuj

    2016-06-01

    Libraries of transposon-insertion alleles constitute powerful and versatile tools for large-scale analysis of yeast gene function. Transposon-insertion libraries are constructed most simply through mutagenesis of a plasmid-based genomic DNA library; modification of the mutagenizing transposon by incorporation of yeast selectable markers, recombination sites, and an epitope tag enables the application of insertion alleles for phenotypic screening and protein localization. In particular, yeast genomic DNA libraries have been mutagenized with modified bacterial transposons carrying the URA3 marker, lox recombination sites, and sequence encoding multiple copies of the hemagglutinin (HA) epitope. Mutagenesis with these transposons has yielded a large resource of insertion alleles affecting nearly 4000 yeast genes in total. Through well-established protocols, these insertion libraries can be introduced into the desired strain backgrounds and the resulting insertional mutants can be screened or systematically analyzed. Relative to alternative methods of UV irradiation or chemical mutagenesis, transposon-insertion alleles can be easily identified by PCR-based approaches or high-throughput sequencing. Transposon-insertion libraries also provide a cost-effective alternative to targeted deletion approaches, although, in contrast to start-codon to stop-codon deletions, insertion alleles might not represent true null-mutants. For protein-localization studies, transposon-insertion alleles can provide encoded epitope tags in-frame with internal codons; in many cases, these transposon-encoded epitope tags can provide a more accurate localization for proteins in which terminal sequences are crucial for intracellular targeting. Thus, overall, transposon-insertion libraries can be used quickly and economically and have a particular utility in screening for desired phenotypes and localization patterns in nonstandard genetic backgrounds.

  5. HOW TO REDUCE NEEDLE INSERTION INDUCED PAIN

    Institute of Scientific and Technical Information of China (English)

    王斌; 董莉

    2001-01-01

    Acupuncture needle insertion always results in pain in the local area due to stimulating the free nerve endings—algesireceptors of the skin. In spite of mildness, this pain may induce many patients' fright, and thus, hinders more extensive application of acupuncture. In the present paper, the author introduces some methods for reducing needle insertion induced pain.

  6. Marginal adaptation of ceramic inserts after cementation

    NARCIS (Netherlands)

    Ozcan, M; Pfeiffer, P; Nergiz, [No Value

    2002-01-01

    The advantage of using ceramic inserts is to prevent major drawbacks of composite resins such as polymerization shrinkage, wear and microleakage. This in vitro study evaluated the marginal adaptation of two approximal ceramic insert systems after cementation to the cavities opened with ultrasonic ti

  7. An Elementary Account of Needle Insertion

    Institute of Scientific and Technical Information of China (English)

    张文兵; 霍则军

    2004-01-01

    @@ Based on the authors' clinical and personal experiences, several pain-inducing factors easily to be ignored by the operators when quick needle insertion is applied, and the authors' first invented slow painless needle insertion method are introduced in the article.

  8. Intradermal normal saline solution, self-selected music, and insertion difficulty effects on intravenous insertion pain.

    Science.gov (United States)

    Jacobson, A F

    1999-01-01

    To examine the effect of listening to self-selected music versus an intradermal injection of normal saline solution on the intensity and distress of intravenous (IV) catheter insertion pain. Prospective, randomized, controlled study. Inpatient and outpatient units in 2 university-affiliated southwestern medical centers. One hundred ten adult inpatients and outpatients undergoing IV therapy. Pain intensity, pain distress, and IV insertion difficulty visual analog scales. Patients were randomly assigned to receive an intradermal injection of normal saline solution, listen with headphones to self-selected music, or be in a control group for IV insertion. A MANOVA revealed no statistically significant multivariate or univariate differences in pain by treatment group, but significantly higher pain distress scores with failed IV insertions. The pain intensity and distress scores were significantly higher in the saline solution group when compared with the music and control groups combined. Insertion difficulty was significantly positively correlated with pain intensity and distress for the entire sample, with weak, nonsignificant correlations in the music group. Intradermal unpreserved saline solution contributes to greater pain intensity and distress, greater insertion difficulty, and a higher failure rate than the use of music or routine IV insertion. Listening to preferred music attenuates the effect of insertion difficulty on IV insertion pain. Intravenous insertion attempts were unsuccessful in more than one third of the subjects, resulting in higher pain distress scores. Further research is needed on interventions to reduce IV insertion pain and on factors contributing to IV insertion failure.

  9. Long-distance effects of insertional mutagenesis.

    Directory of Open Access Journals (Sweden)

    Ruchi Singhal

    Full Text Available BACKGROUND: Most common systems of genetic engineering of mammalian cells are associated with insertional mutagenesis of the modified cells. Insertional mutagenesis is also a popular approach to generate random alterations for gene discovery projects. A better understanding of the interaction of the structural elements within an insertional mutagen and the ability of such elements to influence host genes at various distances away from the insertion site is a matter of considerable practical importance. METHODOLOGY/PRINCIPAL FINDINGS: We observed that, in the context of a lentiviral construct, a transcript, which is initiated at an internal CMV promoter/enhancer region and incorporates a splice donor site, is able to extend past a collinear viral LTR and trap exons of host genes, while the polyadenylation signal, which is naturally present in the LTR, is spliced out. Unexpectedly, when a vector, which utilizes this phenomenon, was used to produce mutants with elevated activity of NF-κB, we found mutants, which owed their phenotype to the effect of the insert on a gene located tens or even hundreds of kilobases away from the insertion site. This effect did not result from a CMV-driven transcript, but was sensitive to functional suppression of the insert. Interestingly, despite the long-distance effect, expression of loci most closely positioned to the insert appeared unaffected. CONCLUSIONS/SIGNIFICANCE: We concluded that a polyadenylation signal in a retroviral LTR, when occurring within an intron, is an inefficient barrier against the formation of a hybrid transcript, and that a vector containing a strong enhancer may selectively affect the function of genes far away from its insertion site. These phenomena have to be considered when experimental or therapeutic transduction is performed. In particular, the long-distance effects of insertional mutagenesis bring into question the relevance of the lists of disease-associated retroviral integration

  10. Insertion sequences enrichment in extreme Red sea brine pool vent

    KAUST Repository

    Elbehery, Ali H. A.

    2016-12-03

    Mobile genetic elements are major agents of genome diversification and evolution. Limited studies addressed their characteristics, including abundance, and role in extreme habitats. One of the rare natural habitats exposed to multiple-extreme conditions, including high temperature, salinity and concentration of heavy metals, are the Red Sea brine pools. We assessed the abundance and distribution of different mobile genetic elements in four Red Sea brine pools including the world’s largest known multiple-extreme deep-sea environment, the Red Sea Atlantis II Deep. We report a gradient in the abundance of mobile genetic elements, dramatically increasing in the harshest environment of the pool. Additionally, we identified a strong association between the abundance of insertion sequences and extreme conditions, being highest in the harshest and deepest layer of the Red Sea Atlantis II Deep. Our comparative analyses of mobile genetic elements in secluded, extreme and relatively non-extreme environments, suggest that insertion sequences predominantly contribute to polyextremophiles genome plasticity.

  11. The insertion of human apolipoprotein H into phospholipid membranes: a monolayer study.

    Science.gov (United States)

    Wang, S X; Cai, G P; Sui, S F

    1998-10-15

    Apolipoprotein H (ApoH) is a plasma glycoprotein isolated from human serum. The interactions of ApoH with lipid membrane were reported to be essential for its physiological and pathogenic roles. In this paper we studied the ability of ApoH to insert into phospholipid membranes using the monolayer approach. The results show that ApoH is surface active and can insert into the lipid monolayers. The insertion ability of ApoH is stronger when a higher content of negatively charged lipids is present in the membrane. The acidic-pH and low-ionic-strength conditions will also enhance ApoH insertion, but these factors may not have much influence on the final insertion ability of ApoH, suggesting that, in the mechanism of ApoH insertion, not only electrostatic forces, but also hydrophobic interactions, are evidently involved. Modification by heat inactivation and reduction/alkylation does not change the critical insertion pressure (pic) of ApoH, suggesting a stable domain, maybe a linear sequence motif, but not the native three-dimensional structure of ApoH, is responsible for its insertion. The extent to which insertion of ApoH into phospholipid membranes may facilitate the 'immune cleaning' of plasma liposomes is discussed.

  12. Spectral analysis of hearing protector impulsive insertion loss.

    Science.gov (United States)

    Fackler, Cameron J; Berger, Elliott H; Murphy, William J; Stergar, Michael E

    2017-01-01

    To characterise the performance of hearing protection devices (HPDs) in impulsive-noise conditions and to compare various protection metrics between impulsive and steady-state noise sources with different characteristics. HPDs were measured per the impulsive test methods of ANSI/ASA S12.42- 2010 . Protectors were measured with impulses generated by both an acoustic shock tube and an AR-15 rifle. The measured data were analysed for impulse peak insertion loss (IPIL) and impulsive spectral insertion loss (ISIL). These impulsive measurements were compared to insertion loss measured with steady-state noise and with real-ear attenuation at threshold (REAT). Tested HPDs included a foam earplug, a level-dependent earplug and an electronic sound-restoration earmuff. IPIL for a given protector varied between measurements with the two impulse noise sources, but ISIL agreed between the two sources. The level-dependent earplug demonstrated level-dependent effects both in IPIL and ISIL. Steady-state insertion loss and REAT measurements tended to provide a conservative estimate of the impulsively-measured attenuation. Measurements of IPIL depend strongly on the source used to measure them, especially for HPDs with less attenuation at low frequencies. ISIL provides an alternative measurement of impulse protection and appears to be a more complete description of an HPD's performance.

  13. The insertion loss of screens under the influence of wind

    DEFF Research Database (Denmark)

    Rasmussen, Karsten Bo; Arranz, Marta Galindo

    1998-01-01

    in the vertical wind speed profile when the wind field passes the screen. Theinfluence of turbulence is also implemented. The experimental part of the investigation relieson a scale model technique based upon a 1:25 scaling ratio and a triggered spark source. Themain results relate to the size of the insertion...... loss of a screen under windy conditions and tothe acoustic importance of the redirection of the flow before and after the screen....

  14. Study of Uranium Oxide Insertion Compounds

    Science.gov (United States)

    1993-01-01

    05 0-6 0-7 08 0.9 x in LiU03 Figure 1.6 Equilibrium discharge curve for lithium insertion into Y-U0 3 at approximately 25’C in 1 M LiBF4 in propylene...insertion into a-U 30 8 at - 25"C in 1M LiBF4 in propylene carbonate/1,2- dimethoxyethane Lithium insertion into a-U 30 8 causes very little change in

  15. Sequential cooling insert for turbine stator vane

    Science.gov (United States)

    Jones, Russell B; Krueger, Judson J; Plank, William L

    2014-04-01

    A sequential impingement cooling insert for a turbine stator vane that forms a double impingement for the pressure and suction sides of the vane or a triple impingement. The insert is formed from a sheet metal formed in a zigzag shape that forms a series of alternating impingement cooling channels with return air channels, where pressure side and suction side impingement cooling plates are secured over the zigzag shaped main piece. Another embodiment includes the insert formed from one or two blocks of material in which the impingement channels and return air channels are machined into each block.

  16. Insertions and the emergence of novel protein structure: a structure-based phylogenetic study of insertions

    Directory of Open Access Journals (Sweden)

    Blouin Christian

    2007-11-01

    Full Text Available Abstract Background In protein evolution, the mechanism of the emergence of novel protein domain is still an open question. The incremental growth of protein variable regions, which was produced by stochastic insertions, has the potential to generate large and complex sub-structures. In this study, a deterministic methodology is proposed to reconstruct phylogenies from protein structures, and to infer insertion events in protein evolution. The analysis was performed on a broad range of SCOP domain families. Results Phylogenies were reconstructed from protein 3D structural data. The phylogenetic trees were used to infer ancestral structures with a consensus method. From these ancestral reconstructions, 42.7% of the observed insertions are nested insertions, which locate in previous insert regions. The average size of inserts tends to increase with the insert rank or total number of insertions in the variable regions. We found that the structures of some nested inserts show complex or even domain-like fold patterns with helices, strands and loops. Furthermore, a basal level of structural innovation was found in inserts which displayed a significant structural similarity exclusively to themselves. The β-Lactamase/D-ala carboxypeptidase domain family is provided as an example to illustrate the inference of insertion events, and how the incremental growth of a variable region is capable to generate novel structural patterns. Conclusion Using 3D data, we proposed a method to reconstruct phylogenies. We applied the method to reconstruct the sequences of insertion events leading to the emergence of potentially novel structural elements within existing protein domains. The results suggest that structural innovation is possible via the stochastic process of insertions and rapid evolution within variable regions where inserts tend to be nested. We also demonstrate that the structure-based phylogeny enables the study of new questions relating to the

  17. Bulkhead insert for an internal combustion engine

    Energy Technology Data Exchange (ETDEWEB)

    Maki, Clifford E.; Chottiner, Jeffrey Eliot; Williams, Rick L.; Thibault, Mark W.; Ervin, James Douglas; Boileau, James Maurice; McKeough, Bryan

    2017-08-01

    An engine includes a cylinder block defining at least one main bearing bulkhead adjacent to a cylinder, and a crankshaft rotatably housed within the block by a main bearing. A bulkhead insert has a cap portion, and an insert portion provided within the bulkhead. The insert portion has having first and second end regions connected by first and second straps. Each strap having a flanged beam cross section. The first and second ends of the insert portion are configured to connect a main bearing cap column to a cylinder head column. Each of the first and second end regions define at least one protrusion having a surface substantially normal to engine combustion and reactive loads. The cap portion is configured to mate with the first end region at the main bearing cap column and support the main bearing.

  18. HB+ inserted into the CMS Solenoid

    CERN Multimedia

    Tejinder S. Virdee, CERN

    2006-01-01

    The first half of the barrel hadron calorimeter (HB+) has been inserted into the superconducting solenoid of CMS, in preparation for the magnet test and cosmic challenge. The operation went smoothly, lasting a couple of days.

  19. Shrink-Fit Solderable Inserts Seal Hermetically

    Science.gov (United States)

    Croucher, William C.

    1992-01-01

    Shrink-fit stainless-steel insert in aluminum equipment housing allows electrical connectors to be replaced by soldering, without degrading hermeticity of housing or connector. Welding could destroy electrostatic-sensitive components and harm housing and internal cables. Steel insert avoids problems because connector soldered directly to it rather than welded to housing. Seals between flange and housing, and between connector and flange resistant to leaks, even after mechanical overloading and thermal shocking.

  20. Transhepatic insertion of vascular dialysis catheters in children: a safe, life-prolonging procedure

    Energy Technology Data Exchange (ETDEWEB)

    Bergey, E.A.; Kaye, R.D.; Reyes, J.; Towbin, R.B. [Department of Radiology, Children`s Hospital of Pittsburgh, PA (United States)

    1999-01-01

    Introduction. Central venous catheters (CVC) have been inserted percutaneously since 1989. This technique has been adapted for transhepatic insertion of large-bore catheters in children with occluded central veins. Materials and methods. Three children aged 5, 11, and 12 years required hemodialysis or plasmaphoresis for treatment of life-threatening conditions. All central veins were occluded, thus transhepatic insertion of a large-bore catheter was necessary. All children underwent successful placement using a combination of ultrasound guidance and fluoroscopy. No complications occurred. Discussion. Transhepatic insertion of large-bore catheters can be performed safely in children. Catheter removal should be accompanied by track embolization to prevent exsanguinating hemorrhage. Conclusion. Transhepatic insertion of dialysis catheters is a safe alternative in children with occluded central veins. (orig.) With 2 figs., 7 refs.

  1. ANALYSIS OF FORCES, ROUGHNESS, WEAR AND TEMPERATURE IN TURNING CAST IRON USING CRYOTREATED CARBIDE INSERTS

    Directory of Open Access Journals (Sweden)

    B.R. Ramji,

    2010-07-01

    Full Text Available The aim of this research was to examine the effect of cryogenic treatment of the coated carbide inserts on their performance in turning gray cast iron work pieces. The cryogenic treatment cycle consisted of cooling the test samples from room temperature to cryogenic temperature of -178.9 C in three hours, soaking at cryogenictemperature around 24 hours and warming to room temperature in about five hours. Cutting forces, surface roughness, flank wear and tool tip temperature were studied for both coated and coated-treated inserts. ANOVA was performed to identify the effect of the parameters on the response variables. Cryogenically treated inserts proved superior to the non-treated in all the test conditions in terms of lesser flank wear of the inserts and reduced surface roughness of the specimens. The after turned inserts were examined using Scanning Electron Microscopy for studying the flank wear mechanism.

  2. Comparison of trapezius squeeze test and jaw thrust as clinical indicators for laryngeal mask airway insertion in spontaneously breathing children.

    Science.gov (United States)

    Dinesh Kumar, K K; Bhardwaj, Neerja; Yaddanapudi, Sandhya

    2017-01-01

    It is not known whether trapezius squeeze test (TPZ) is a better clinical test than jaw thrust (JT) to assess laryngeal mask airway (LMA) insertion conditions in children under sevoflurane anesthesia. After the Institutional Ethics Committee approval and written informed parental consent, 124 American Society of Anesthesiologists I and II children of 2-8 years of age undergoing minor surgical procedures were randomized into TPZ and JT groups. The children were induced with 8% sevoflurane in oxygen at a fresh gas flow of 4 L/min. TPZ or JT was performed after 1 min of start of sevoflurane and then every 20 s till the test was negative, when end-tidal (ET) sevoflurane concentration was noted. Classic LMA of requisite size was inserted by a blinded anesthetist and conditions at the insertion of LMA, insertion time, and the number of attempts of LMA insertion were recorded. The mean LMA insertion time was significantly longer (P < 0.001) for TPZ (145 ± 28.7 sec) compared to JT group (111.8 ± 31.0 sec). ET sevoflurane concentration at the time of LMA insertion was comparable in the two groups. LMA insertion conditions were similar in the two groups. There was no difference between the two groups regarding total number of attempts of LMA insertion. Heart rate (HR) decreased in both groups after LMA insertion (P < 0.001) but TPZ group had significantly lower HR compared with the JT group up to 5 min after LMA insertion (P = 0.03). Both JT and TPZ are equivalent clinical indicators in predicting the optimal conditions of LMA insertion in spontaneously breathing children; however, it takes a longer time to achieve a negative TPZ squeeze test.

  3. Hamstring tendons insertion - an anatomical study

    Directory of Open Access Journals (Sweden)

    Cristiano Antonio Grassi

    2013-09-01

    Full Text Available OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT, tibial plateau (TP and tibial tuberosity (TT. A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the medial border of the patellar tendon and tibial tuberosity to the insertion of the flexor tendons of the knee. The angle between tibial plateau and the insertion of the flexor tendons of the knee (A-TP-FT was calculated using Image Pro Plus software. RESULTS: The mean distance TP-FT was 41 ± 4.6 mm. The distance between the TT-FT was 6.88 ± 1 mm. The (A-TP-FT was 20.3 ± 4.9°. CONCLUSION: In the anterior tibial flexor tendons are about 40 mm from the plateau with an average of 20°.

  4. RERTR-12 Insertion 2 Irradiation Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    D. M. Perez; G. S. Chang; D. M. Wachs; G. A. Roth; N. E. Woolstenhulme

    2012-09-01

    The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications.1 RERTR-12 insertion 2 includes the capsules irradiated during the last three irradiation cycles. These capsules include Z, Y1, Y2 and Y3 type capsules. The following report summarizes the life of the RERTR-12 insertion 2 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.

  5. Compact insert design for cryogenic pressure vessels

    Science.gov (United States)

    Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco; Petitpas, Guillaume; Switzer, Vernon A.

    2017-06-14

    A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.

  6. On the Insertion Time of Cuckoo Hashing

    CERN Document Server

    Fountoulakis, Nikolaos; Steger, Angelika

    2010-01-01

    Cuckoo hashing is an efficient technique for creating large hash tables with high space utilization and guaranteed constant access times. There, each item can be placed in a location given by any one out of k different hash functions. In this paper we investigate further the random walk heuristic for inserting in an online fashion new items into the hash table. Provided that k > 2 and that the number of items in the table is below (but arbitrarily close) to the theoretically achievable load threshold, we show a polylogarithmic bound for the maximum insertion time that holds with high probability.

  7. Insertional Achilles tendinitis and Haglund's deformity.

    Science.gov (United States)

    Kang, Steve; Thordarson, David B; Charlton, Timothy P

    2012-06-01

    Haglund's deformity is an enlargement of the posterosuperior prominence of the calcaneus, which is frequently associated with insertional Achilles tendinitis. To our knowledge, no study has been done successfully correlating the characteristics of a Haglund's deformity with insertional Achilles tendinitis. The purpose of our study was to analyze the characteristics of a Haglund's deformity in patients with and without insertional Achilles tendinitis to see if there was a correlation. The study was a retrospective radiographic review of a single surgeon's patients with insertional Achilles tendinitis from 2005 to 2008. Our study population consisted of 44 patients, 48 heels (22 male, 22 female) with insertional Achilles tendinitis, with a mean age of 52 (range, 23 to 79) years. Our control population consisted of 50 patients (25 males, 25 females) and 50 heels without insertional Achilles tendinitis with a mean age of 55.6 (range, 18 to 89) years. We introduced two new measurements of the Haglund's deformity in this study: the Haglund's deformity height and peak angle. A standing lateral foot or ankle radiograph was analyzed for each patient and the following measurements were made: Haglund deformity height and peak angle; Bohler's angle; Fowler-Philip angle; and parallel pitch sign. We also looked for the presence of calcification in the study group and the length and width of the calcification. Unpaired t-test was used to analyze the measurements between the groups. Ten patients' radiographs were re-measured and correlation coefficients were obtained to assess the reliability of the measuring techniques. For the insertional Achilles tendinitis group, the mean Haglund's deformity height was 9.6 (range, 5.3 to 15.3) mm and the mean Haglund's deformity peak angle was 105 (range, 87 to 123) degrees. Calcification was present in 35 of 48 or (73%) of patients with a mean length of 13.3 (range, 3.2 to 41.9) mm and mean width of 4.5 (range, 1.0 to 10.4) mm. In the control

  8. Thermal Performance of the XRS Helium Insert

    Science.gov (United States)

    Breon, Susan R.; DiPirro, Michael J.; Tuttle, James G.; Shirron, Peter J.; Warner, Brent A.; Boyle, Robert F.; Canavan, Edgar R.

    1999-01-01

    The X-Ray Spectrometer (XRS) is an instrument on the Japanese Astro-E satellite, scheduled for launch early in the year 2000. The XRS Helium Insert comprises a superfluid helium cryostat, an Adiabatic Demagnetization Refrigerator (ADR), and the XRS calorimeters with their cold electronics. The calorimeters are capable of detecting X-rays over the energy range 0.1 to 10 keV with a resolution of 12 eV. The Helium Insert completed its performance and verification testing at Goddard in January 1999. It was shipped to Japan, where it has been integrated with the neon dewar built by Sumitomo Heavy Industries. The Helium Insert was given a challenging lifetime requirement of 2.0 years with a goal of 2.5 years. Based on the results of the thermal performance tests, the predicted on-orbit lifetime is 2.6 years with a margin of 30%. This is the result of both higher efficiency in the ADR cycle and the low temperature top-off, more than compensating for an increase in the parasitic heat load. This paper presents a summary of the key design features and the results of the thermal testing of the XRS Helium Insert.

  9. Methidium intercalator inserted into synthetic oligonucleotides.

    Energy Technology Data Exchange (ETDEWEB)

    Timofeev, E. N.; Smirnov, I. P.; Haff, L. A.; Tishchenko, E. I.; Mirzabekov, A. D.; Florentiev, V. L.; Center for Mechanistic Biology and Biotechnology; Engelhardt Inst. of Molecular Biology; PerSeptive BioSystems Inc.

    1996-01-01

    A new methidium intercalator phosphoramidite has been synthesized. Methidium incorporation into an oligonucleotide during the synthesis was confirmed by UV and MALDI TOF MS data. UV melting experiments showed enhanced stability of a duplex, containing internal methidium. Methidium phosphoramidite has been synthesized and used for insertion of intercalator into the deoxyoligonucleotides.

  10. Aspects of insertion in random trees

    NARCIS (Netherlands)

    Bagchi, Arunabha; Reingold, E.M.

    1982-01-01

    A method formulated by Yao and used by Brown has yielded bounds on the fraction of nodes with specified properties in trees bult by a sequence of random internal nodes in a random tree built by binary search and insertion, and show that in such a tree about bounds better than those now known. We the

  11. Aspects of insertion in random trees

    NARCIS (Netherlands)

    Bagchi, Arunabha; Reingold, E.M.

    1982-01-01

    A method formulated by Yao and used by Brown has yielded bounds on the fraction of nodes with specified properties in trees bult by a sequence of random internal nodes in a random tree built by binary search and insertion, and show that in such a tree about bounds better than those now known. We

  12. The design and analysis of transposon insertion sequencing experiments.

    Science.gov (United States)

    Chao, Michael C; Abel, Sören; Davis, Brigid M; Waldor, Matthew K

    2016-02-01

    Transposon insertion sequencing (TIS) is a powerful approach that can be extensively applied to the genome-wide definition of loci that are required for bacterial growth under diverse conditions. However, experimental design choices and stochastic biological processes can heavily influence the results of TIS experiments and affect downstream statistical analysis. In this Opinion article, we discuss TIS experimental parameters and how these factors relate to the benefits and limitations of the various statistical frameworks that can be applied to the computational analysis of TIS data.

  13. Insertion loads and forearm muscle activity during flexible hose insertion tasks.

    Science.gov (United States)

    Grieshaber, D Christian; Armstrong, Thomas J

    2007-10-01

    To quantify the physical demands of hose insertion tasks in automotive assembly operations and how they are affected by method and the mechanical interference between the hose and the flange. Insertion tasks were identified by workers as physically demanding and can often lead to fatigue or losses in production attributable to pain or injury. Six male and 6 female participants pushed a 25.4-mm flexible rubber hose onto a stationary flange during simulated insertions. Three insertion methods -- rock, straight, and twist -- were examined in the study. Muscle activity of the finger flexors was recorded to estimate grip effort during the simulated insertions. The twist method (114.8 N) resulted in a 26% reduction in axial force compared with the straight method (155.7 N). Average muscle activity ranged from a low of 14% maximum voluntary contraction (MVC; men, straight method) to a high of 67% MVC (women, twist method). Hose resultant forces ranged from a low of 52.2 N to a high of 461.1 N for all participants. Men exerted 6% higher resultant forces with 37% less muscle activity than women. There are situations when the 26% reduction in the axial force attributable to twisting may be helpful during an insertion, despite the fact that forearm muscle activity was highest for both male and female participants during twisting insertions. The results of this study can be applied to the future design of tasks that involve the joining of two parts such as a hose and flange.

  14. A critical appraisal of medication package inserts

    Directory of Open Access Journals (Sweden)

    Pranjit Narzaree

    2015-10-01

    Full Text Available Introduction: Package Inserts (PIs refers to officially specified document that accompanies a drug for relevant, updated and unbiased information for rational drug use based on regulatory guidelines as per section 6.2 and 6.3 of schedule D of Indian Drug and cosmetic Act 1945. But some studies had shown non-uniformity with suboptimal level of informations which frequently can lead to medication errors. Hence this study was conducted to evaluate the completeness of PIs.Aim: To critically evaluate package inserts of allopathic medicines.Material and Methods: 100 allopathic drug PIs were collected from pharmacies in Rohtak and were checked for the presence of each heading as per schedule D criteria, followed by scrutiny of the information included under the heading. Indian guidelines were also compared with US FDA guidelines for PIs.Scoring of package inserts: The informations were evaluated for completeness and scored as 1 if present otherwise scored as zero for no information or partial information. Scores for each heading were calculated by totaling the scores of all the package inserts. The total scores were expressed as absolute numbers and percentages.Results:  On an average PIs analyzed for the completeness of the criteria scored 10 (Mean± SD = 9.73±2.48 out of 16. Absence of common layout and headings caused inconvenience. In comparison to US FDA guidelines it lacked, disclaimer statement, boxed warning, revision date, approval date, toll-free number etc.Conclusion: PIs don’t seem to be serving effectively because of multiple deficiencies like completeness, uniformity, absence of headings.Keywords: Critical appraisal, package inserts.

  15. COMPARATIVE STUDY OF EARLY POSTPARTUM IUCD INSERTION TO INTERVAL IUCD INSERTION

    Directory of Open Access Journals (Sweden)

    Shibani Devi

    2016-07-01

    Full Text Available INTRODUCTION According to National Family Health Survey-3, Indian women have 13% unmet need for contraception and according to District Level Household & Facility Survey-3, it is 21.3% in the postpartum period. Postpartum intrauterine contraceptive device insertion - both immediately post-placental delivery and somewhat later, but within 48 hours after delivery are options which merit consideration as the woman is likely to have a high motivation for accepting contraception and the healthcare centre provides a convenient setting for insertion of IUCD. AIM Comparison of efficacy and complications of IUCD insertions in post-placental with interval period: 6-month followup. METHOD This perspective study was conducted among 100 women: - 50 women had IUCD inserted within 10 minutes of placental delivery and 50 had insertion more than 6 weeks after delivery. They were followed till 6 months post insertion and were compared regarding early and late complications, continuation rates and expulsion rates. RESULT At the end of six months, we found higher occurrence of lower abdominal pain, heavy menstrual bleeding in case of interval insertion as compared to post-placental insertion which was statistically significant (p value-0.04 & 0.007 respectively. However, the expulsion rates of post-placental IUCD were somewhat elevated (14% compared to interval insertions (2%. Continuation rates at the end of 6 months in both the groups were 82% and 86% respectively which is comparable. CONCLUSION Post-placental IUCD is thus found to be an ideal method to meet the unmet need of postpartum women as it is easily accessible and convenient for both women and their health care providers, is associated with less discomfort and fewer side effects and allow women to obtain safe, long acting, highly effective contraception while still in the health care system.

  16. Comparison of conventional Injection Mould Inserts to Additively Manufactured Inserts using Life Cycle Assessment

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Bey, Niki; Mischkot, Michael

    2016-01-01

    Polymer Additive Manufacturing can be used to produce soft tooling inserts for injection moulding. Compared to conventional tooling, the energy and time consumption during production are significantly lower. As the life time of such inserts is significantly shorter than the life time of traditional...... of their potential environmental impact and yield throughout the development and pilot phase. Insert geometry is particularly advantageous for pilot production and small production sizes. In this research, Life Cycle Assessment is used to compare the environmental impact of soft tooling by Additive Manufacturing...... (using Digital Light Processing) and three traditional methods for the manufacture of inserts (milling of brass, steel, and aluminium) for injection moulds during the pre-production phase....

  17. Comparison of conventional Injection Mould Inserts to Additively Manufactured Inserts using Life Cycle Assessment

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Bey, Niki; Mischkot, Michael

    2016-01-01

    Polymer Additive Manufacturing can be used to produce soft tooling inserts for injection moulding. Compared to conventional tooling, the energy and time consumption during production are significantly lower. As the life time of such inserts is significantly shorter than the life time of traditional...... of their potential environmental impact and yield throughout the development and pilot phase. Insert geometry is particularly advantageous for pilot production and small production sizes. In this research, Life Cycle Assessment is used to compare the environmental impact of soft tooling by Additive Manufacturing...... (using Digital Light Processing) and three traditional methods for the manufacture of inserts (milling of brass, steel, and aluminium) for injection moulds during the pre-production phase....

  18. Development of ocular inserts for cattle.

    Science.gov (United States)

    Greer, R T; Ryoo, J P

    1987-06-01

    Ring shaped ocular inserts have been developed to administer a therapeutic level of tylosin tartrate throughout a five day period to treat pinkeye in cattle. The inserts are based on polyvinyl chloride rings which are dip coated with a copolymer containing the antibiotic (tylosin tartrate). Scanning electron microscope (SEM) characterization of surfaces has been of value to evaluate the presence and extent of surface flaws in the hydrogel coating, and to contribute to improvement in fabrication of the rings to insure the establishment of satisfactory seals at joints, uniformity of microporosity and cross sections, and the absence of significant cracking or flaking. In vitro release rates were determined using thin layer chromatography techniques, and rates were seen to be above a few micrograms of antibiotic per hour for experiments as long as nine days at simulated tear rates as high as 2 milliliters per hour.

  19. Perception and Action in Teleoperated Needle Insertion.

    Science.gov (United States)

    Nisky, I; Pressman, A; Pugh, C M; Mussa-Ivaldi, F A; Karniel, A

    2011-01-01

    We studied the effect of delay on perception and action in contact with a force field that emulates elastic soft tissue with a rigid nonlinear boundary. Such a field is similar to forces exerted on a needle during teleoperated needle insertion. We found that delay causes motor underestimation of the stiffness of this nonlinear soft tissue, without perceptual change. These experimental results are supported by simulation of a simplified mechanical model of the arm and neural controller, and a model for perception of stiffness, which is based on regression in the force-position space. In addition, we show that changing the gain of the teleoperation channel cancels the motor effect of delay without adding perceptual distortion. We conclude that it is possible to achieve perceptual and motor transparency in virtual one-dimensional remote needle insertion task.

  20. Complex central venous catheter insertion for hemodialysis.

    Science.gov (United States)

    Powell, Steven; Belfield, Jane

    2014-01-01

    Despite the introduction of payment by results in the UK, there has been no decrease in central venous catheter (CVC) use. In part, this may relate to a requirement to dialyse through a CVC while autogenous access matures. Mortality data have improved in parallel and patients on hemodialysis live longer, which may lead to an increased exposure to CVCs.Exposure to CVCs carries a significant risk of infection and occlusion requiring their repositioning or exchange. The mid to long-term sequelae of CVC use is central venous occlusion leaving clinical teams with an ever increasing challenge to find adequate venous access.In this article, we will discuss the challenges faced by operators inserting CVCs into the hemodialysis-dependent patient who has exhausted more tradition insertion sites. These include translumbar caval catheters, transocclusion and transcollateral catheters, transjugular Inferior Vena Cava catheter positioning, and transhepatic catheters. We will demonstrate the techniques employed, complications, and anticipated longevity of function.

  1. Comparison of insertional RNA editing in Myxomycetes.

    Directory of Open Access Journals (Sweden)

    Cai Chen

    Full Text Available RNA editing describes the process in which individual or short stretches of nucleotides in a messenger or structural RNA are inserted, deleted, or substituted. A high level of RNA editing has been observed in the mitochondrial genome of Physarum polycephalum. The most frequent editing type in Physarum is the insertion of individual Cs. RNA editing is extremely accurate in Physarum; however, little is known about its mechanism. Here, we demonstrate how analyzing two organisms from the Myxomycetes, namely Physarum polycephalum and Didymium iridis, allows us to test hypotheses about the editing mechanism that can not be tested from a single organism alone. First, we show that using the recently determined full transcriptome information of Physarum dramatically improves the accuracy of computational editing site prediction in Didymium. We use this approach to predict genes in the mitochondrial genome of Didymium and identify six new edited genes as well as one new gene that appears unedited. Next we investigate sequence conservation in the vicinity of editing sites between the two organisms in order to identify sites that harbor the information for the location of editing sites based on increased conservation. Our results imply that the information contained within only nine or ten nucleotides on either side of the editing site (a distance previously suggested through experiments is not enough to locate the editing sites. Finally, we show that the codon position bias in C insertional RNA editing of these two organisms is correlated with the selection pressure on the respective genes thereby directly testing an evolutionary theory on the origin of this codon bias. Beyond revealing interesting properties of insertional RNA editing in Myxomycetes, our work suggests possible approaches to be used when finding sequence motifs for any biological process fails.

  2. Comparison of Insertional RNA Editing in Myxomycetes

    Science.gov (United States)

    Chen, Cai; Frankhouser, David; Bundschuh, Ralf

    2012-01-01

    RNA editing describes the process in which individual or short stretches of nucleotides in a messenger or structural RNA are inserted, deleted, or substituted. A high level of RNA editing has been observed in the mitochondrial genome of Physarum polycephalum. The most frequent editing type in Physarum is the insertion of individual Cs. RNA editing is extremely accurate in Physarum; however, little is known about its mechanism. Here, we demonstrate how analyzing two organisms from the Myxomycetes, namely Physarum polycephalum and Didymium iridis, allows us to test hypotheses about the editing mechanism that can not be tested from a single organism alone. First, we show that using the recently determined full transcriptome information of Physarum dramatically improves the accuracy of computational editing site prediction in Didymium. We use this approach to predict genes in the mitochondrial genome of Didymium and identify six new edited genes as well as one new gene that appears unedited. Next we investigate sequence conservation in the vicinity of editing sites between the two organisms in order to identify sites that harbor the information for the location of editing sites based on increased conservation. Our results imply that the information contained within only nine or ten nucleotides on either side of the editing site (a distance previously suggested through experiments) is not enough to locate the editing sites. Finally, we show that the codon position bias in C insertional RNA editing of these two organisms is correlated with the selection pressure on the respective genes thereby directly testing an evolutionary theory on the origin of this codon bias. Beyond revealing interesting properties of insertional RNA editing in Myxomycetes, our work suggests possible approaches to be used when finding sequence motifs for any biological process fails. PMID:22383871

  3. Comparison of insertional RNA editing in Myxomycetes.

    Science.gov (United States)

    Chen, Cai; Frankhouser, David; Bundschuh, Ralf

    2012-01-01

    RNA editing describes the process in which individual or short stretches of nucleotides in a messenger or structural RNA are inserted, deleted, or substituted. A high level of RNA editing has been observed in the mitochondrial genome of Physarum polycephalum. The most frequent editing type in Physarum is the insertion of individual Cs. RNA editing is extremely accurate in Physarum; however, little is known about its mechanism. Here, we demonstrate how analyzing two organisms from the Myxomycetes, namely Physarum polycephalum and Didymium iridis, allows us to test hypotheses about the editing mechanism that can not be tested from a single organism alone. First, we show that using the recently determined full transcriptome information of Physarum dramatically improves the accuracy of computational editing site prediction in Didymium. We use this approach to predict genes in the mitochondrial genome of Didymium and identify six new edited genes as well as one new gene that appears unedited. Next we investigate sequence conservation in the vicinity of editing sites between the two organisms in order to identify sites that harbor the information for the location of editing sites based on increased conservation. Our results imply that the information contained within only nine or ten nucleotides on either side of the editing site (a distance previously suggested through experiments) is not enough to locate the editing sites. Finally, we show that the codon position bias in C insertional RNA editing of these two organisms is correlated with the selection pressure on the respective genes thereby directly testing an evolutionary theory on the origin of this codon bias. Beyond revealing interesting properties of insertional RNA editing in Myxomycetes, our work suggests possible approaches to be used when finding sequence motifs for any biological process fails.

  4. Guided pedicle screw insertion: techniques and training.

    Science.gov (United States)

    Manbachi, Amir; Cobbold, Richard S C; Ginsberg, Howard J

    2014-01-01

    In spinal fusion surgery, the accuracy with which screws are inserted in the pedicle has a direct effect on the surgical outcome. Accurate placement generally involves considerable judgmental skills that have been developed through a lengthy training process. Because the impact of misaligning one or more pedicle screws can directly affect patient safety, a number of navigational and trajectory verification approaches have been described and evaluated in the literature to provide some degree of guidance to the surgeon. To provide a concise review to justify the need and explore the current state of developing navigational or trajectory verification techniques for ensuring proper pedicle screw insertion along with simulation methods for better educating the surgical trainees. Recent literature review. To justify the need to develop new methods for optimizing pedicle screw paths, we first reviewed some of the recent publications relating to the statistical outcomes for different types of navigation along with the conventional freehand (unassisted) screw insertion. Second, because of the importance of providing improved training in the skill of accurate screw insertion, the training aspects of relevant techniques are considered. The third part is devoted to the description of specific navigational assist methods or trajectory verification techniques and these include computer-assisted navigation, three-dimensional simulations, and also electric impedance and optical and ultrasonic image-guided methods. This article presents an overview of the need and the current status of the guidance methods available for improving the surgical outcomes in spinal fusion procedures. It also describes educational aids that have the potential for reducing the training process. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Anionic phospholipids modulate peptide insertion into membranes.

    Science.gov (United States)

    Liu, L P; Deber, C M

    1997-05-06

    While the insertion of a hydrophobic peptide or membrane protein segment into the bilayer can be spontaneous and driven mainly by the hydrophobic effect, anionic lipids, which comprise ca. 20% of biological membranes, provide a source of electrostatic attractions for binding of proteins/peptides into membranes. To unravel the interplay of hydrophobicity and electrostatics in the binding of peptides into membranes, we designed peptides de novo which possess the typical sequence Lys-Lys-Ala-Ala-Ala-X-Ala-Ala-Ala-Ala-Ala-X-Ala-Ala-Trp-Ala-Ala-X-Ala-Al a-Ala-Lys-Lys-Lys-Lys-amide, where X residues correspond to "guest" residues which encompass a range of hydrophobicity (Leu, Ile, Gly, and Ser). Circular dichroism spectra demonstrated that peptides were partially (40-90%) random in aqueous buffer but were promoted to form 100% alpha-helical structures by anionic lipid micelles. In neutral lipid micelles, only the relatively hydrophobic peptides (X = L and I) spontaneously adopted the alpha-helical conformation, but when 25% of negatively charged lipids were mixed in to mimic the content of anionic lipids in biomembranes, the less hydrophobic (X = S and G) peptides then formed alpha-helical conformations. Consistent with these findings, fluorescence quenching by the aqueous-phase quencher iodide indicated that in anionic (dimyristoylphosphatidylglycerol) vesicles, the peptide Trp residue was buried in the lipid vesicle hydrophobic core, while in neutral (dimyristoylphosphatidylcholine) vesicles, only hydrophobic (X = L and I) peptides were shielded from the aqueous solution. Trp emission spectra of peptides in the presence of phospholipids doxyl-labeled at the 5-, 7-, 10-, 12-, and 16-fatty acid positions implied not only a transbilayer orientation for inserted peptides but also that mixed peptide populations (transbilayer + surface-associated) may arise. Overall results suggest that for hydrophobic peptides with segmental threshold hydrophobicity below that which

  6. Thought insertion, cognitivism, and inner space.

    Science.gov (United States)

    Thornton, Tim

    2002-08-01

    Whatever its underlying causes, even the description of the phenomenon of thought insertion, of the content of the delusion, presents difficulty. It may seem that the best hope of a description comes from a broadly cognitivist approach to the mind which construes content-laden mental states as internal mental representations within what is literally an inner space: the space of the brain or nervous system. Such an approach objectifies thoughts in a way which might seem to hold out the prospect of describing the ''alienated'' relation to one's own thoughts that seems to be present in thought insertion.1 Firstly, I examine the general structure of cognitivist accounts of intentional or content-laden mental states. I raise the general difficulty of explaining how free-standing, and thus world-independent, inner states can still have bearing on the outer world. Secondly, I briefly examine Frith's model for explaining thought insertion and other passivity phenomena by postulating a failure of an internal monitoring mechanism of inner states. I question what account can be given of non-pathological cases and raise two specific objects. Cognitivist accounts of the mind face a general, and possibly insuperable, challenge: explaining the intentionality of mental states in non-intentional, nonquestion-begging terms. There have so far been no satisfactory solutions. Cognitivist accounts of passivity phenomena in terms of a failure of internal monitoring face two objections. Firstly, accounting for non-pathological cases generates an infinite regress. Secondly, no account can be given of the paradoxical nature of utterances of the form of Moore's paradox: ''it is raining but I do not believe it''. A cognitivist approach presents an alienated account of thought in normal, non-pathological cases and is no help in accounting for thought insertion.

  7. Pericardial Effusion and Cardiac Tamponade Following Percutaneously Inserted Central Line Insertion in an Extremely Low-birth-weight Baby: Case Report and Successful Management

    Science.gov (United States)

    Desai, Avinash V.; Kumar, Abnish; Shanbhag, Praful; Shah, Forum

    2017-01-01

    Pericardial effusion and cardiac tamponade are rare complications of percutaneously inserted central lines (PICLs), in extremely low-birth-weight babies. This particular complication carries a high degree of mortality, if not suspected and diagnosed. Bedside echocardiography proves not only diagnostic but also can be lifesaving in these conditions. Here, we wish to report such a baby who suddenly deteriorated and showed cardiovascular instability 2 days after the insertion of PICL. Immediate bedside echocardiography helped pick up the effusion which was drained using a subxiphoid percutaneous approach. PMID:28197055

  8. App-assisted external ventricular drain insertion.

    Science.gov (United States)

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  9. [Historical evolution of package inserts in Brazil].

    Science.gov (United States)

    Caldeira, Telma Rodrigues; Neves, Eugênio Rodrigo Zimmer; Perini, Edson

    2008-04-01

    In Brazil, package inserts provide key information on pharmaceuticals. The current study analyzes the evolution of package inserts and the impact on this process by scientific research and development, globalization of information, and various health policies. The study began with a retrospective review of Brazilian health legislation until 1920, the year when the National Public Health Department was created. The analysis of documents on the evolution of health regulation in Brazil began with the Brazilian Pharmaceutical Collection-Health Rulings. The second stage of the study involved a search of standards and norms in VISALEGIS: Health Surveillance Legislation, Portal for Legislation from the National Congressional Information System and the Health Legislation System. Package inserts became an important vehicle for information in the country and underwent important regulatory changes in the latter half of the 20th century. From 1946 to 2006, the number of mandatory items increased, with more in-depth description. However, the standardization of information for medicines with the same active ingredient failed to materialize, despite its importance and the various legal initiatives in this direction.

  10. Beamline Insertions Manager at Jefferson Lab

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Michael C. [Jefferson Lab., Newport News, VA (United States)

    2015-09-01

    The beam viewer system at Jefferson Lab provides operators and beam physicists with qualitative and quantitative information on the transverse electron beam properties. There are over 140 beam viewers installed on the 12 GeV CEBAF accelerator. This paper describes an upgrade consisting of replacing the EPICS-based system tasked with managing all viewers with a mixed system utilizing EPICS and high-level software. Most devices, particularly the beam viewers, cannot be safely inserted into the beam line during high-current beam operations. Software is partly responsible for protecting the machine from untimely insertions. The multiplicity of beam-blocking and beam-vulnerable devices motivates us to try a data-driven approach. The beamline insertions application components are centrally managed and configured through an object-oriented software framework created for this purpose. A rules-based engine tracks the configuration and status of every device, along with the beam status of the machine segment containing the device. The application uses this information to decide on which device actions are allowed at any given time.

  11. A coated electrode carrier for cochlear implantation reduces insertion forces.

    Science.gov (United States)

    Radeloff, Andreas; Unkelbach, Marc H; Mack, Martin G; Settevendemie, Claudia; Helbig, Silke; Mueller, Joachim; Hagen, Rudolf; Mlynski, Robert

    2009-05-01

    To assess the insertion forces and feasibility of insertion of a prototype electrode carrier coated with a flexible and biodegradable coating developed for lubrication and drug delivery. Experimental study. Eight coated and eight uncoated electrode carriers were inserted into a scala tympani model by means of an insertion device, and forces produced during insertion were determined in near real time. The maximum insertion depths and insertion angle were determined. To test the handling and operability, five coated electrode carriers were implanted into human temporal bones. Additionally, the bones were processed undecalcified and the distribution of the coating material within the cochlea evaluated. Insertion forces were markedly reduced in the group of coated electrode carriers for insertion depths above 15 mm. The insertions were less fitful and led to a higher maximum insertion angle. The insertion of the coated electrode carrier was feasible, and the coating material was evident up to the apical parts of the cochlea postimplantation. Coating of a cochlear implant electrode carrier may reduce insertion forces responsible for the surgical trauma. Loaded with active substances, the coating may help to deliver drugs to the apical parts of the cochlear where hair cells reside in patients with residual hearing.

  12. Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J. [Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States); Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, State College, Pennsylvania 16802 (United States); Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 and Mechanical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2012-04-15

    Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

  13. Heat Transfer Behavior in a Square Duct with Tandem Wire Coil Element Insert

    Institute of Scientific and Technical Information of China (English)

    Smith Eiamsa-ard; Narin Koolnapadol; Pongjet Promvonge

    2012-01-01

    Effects of insertion of tandem wire coil elements used as turbulator on heat transfer and turbulent flow friction characteristics in a uniform heat-flux square duct are experimentally investigated in this work. The experiment is conducted for turbulent flow with the Reynolds number from 4000 to 25000. The wire coil element is inserted into the duct with a view to generating a swirl flow that assists to wash up the flow trapped in the duct corners and then increase the heat transfer rate of the test duct. Apart from the full-length coil, 1D and 2D length coil elements placed in tandem inside the duct with various free-space lengths are introduced to reduce the friction loss. The results obtained from these wire coil element inserts are also compared with those from the smooth duct. The experimental results reveal that the use of wire coil inserts for the full-length coil, 1D and 2D coil elements with a short free-space length leads to a considerable increase in heat transfer and friction loss over the smooth duct with no insert. The full-length wire coil provides higher heat transfer and friction factor than the tandem wire coil elements under the same operating conditions. Also, performance evaluation criteria to assess the real benefits in using the wire coil insert into the square duct are determined.

  14. Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy.

    Science.gov (United States)

    McGill, Carl S; Schwartz, Jonathon A; Moore, Jason Z; McLaughlin, Patrick W; Shih, Albert J

    2012-04-01

    In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Needle insertion experiments into phantom were performed using a 2(2) factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

  15. New cardiac retractor for epicardial electrode insertion via subxiphoid approach.

    Science.gov (United States)

    Sakamoto, T; Arai, H; Suzuki, A

    1993-04-01

    A new retractor for the insertion of epicardial screw-in electrodes is described. We have found that this instrument can be easily applied to the heart and gives excellent exposure for electrode insertion.

  16. Experimental testing of exchangeable cutting inserts cutting ability

    OpenAIRE

    Čep, Robert; Janásek, Adam; Čepová Lenka; Petrů, Jana; Ivo HLAVATÝ; Car, Zlatan; Hatala, Michal

    2013-01-01

    The article deals with experimental testing of the cutting ability of exchangeable cutting inserts. Eleven types of exchangeable cutting inserts from five different manufacturers were tested. The tested cutting inserts were of the same shape and were different especially in material and coating types. The main aim was both to select a suitable test for determination of the cutting ability of exchangeable cutting inserts and to design such testing procedure that could make it possible...

  17. Noise reduction in supersonic jets by nozzle fluidic inserts

    Science.gov (United States)

    Morris, Philip J.; McLaughlin, Dennis K.; Kuo, Ching-Wen

    2013-08-01

    Professor Philip Doak spent a very productive time as a consultant to the Lockheed-Georgia Company in the early 1970s. The focus of the overall research project was the prediction and reduction of noise from supersonic jets. Now, 40 years on, the present paper describes an innovative methodology and device for the reduction of supersonic jet noise. The goal is the development of a practical active noise reduction technique for low bypass ratio turbofan engines. This method introduces fluidic inserts installed in the divergent wall of a CD nozzle to replace hard-wall corrugation seals, which have been demonstrated to be effective by Seiner (2005) [1]. By altering the configuration and operating conditions of the fluidic inserts, active noise reduction for both mixing and shock noise has been obtained. Substantial noise reductions have been achieved for mixing noise in the maximum noise emission direction and in the forward arc for broadband shock-associated noise. To achieve these reductions (on the order of greater than 4 and 2 dB for the two main components respectively), practically achievable levels of injection mass flow rates have been used. The total injected mass flow rates are less than 4% of the core mass flow rate and the effective operating injection pressure ratio has been maintained at or below the same level as the nozzle pressure ratio of the core flow.

  18. Bonding of ceramic insert to a laboratory particle filler composite.

    Science.gov (United States)

    Kienanen, Pietari; Alander, Pasi; Lassila, Lippo V J; Vallittu, Pekka K

    2005-10-01

    The push-out bond strength of cylindrical ceramic inserts (CI) to particulate filler resin composite (VC) was evaluated in this study. Various surface treatments to improve the adhesion of CI to resin composite were tested. Additionally, the effect of fiber-reinforced composite (FRC) laminate encapsulation around CI was tested. Feldspathic porcelain CI with a diameter of 3.1 mm was bonded to VC. Adhesive resin was used for bonding. In group 1, no surface treatment of CI was done. In group 2, CI was encapsulated with a thin layer of woven glass FRC. In group 3, the surface of the CI was tribochemically silica coated and silanized. In group 4, the surface of the CI was grit-blasted with 50 microm aluminum oxide and etched with hydrofluoric acid. In group 5, the grit-blasted CI was encapsulated with a layer of FRC. The specimens (n = 6/group) were either dry stored or thermocycled in water (6000 x 5-55 degrees C). The push-out test was carried out with a universal material testing machine. The highest push-out strength was achieved in group 5 (20.4 MPa) and the lowest in group 2 (11.5 MPa). ANOVA revealed that both surface treatment and storage condition had a significant effect on push-out strength (p < 0.05). We conclude that the additional glass FRC encapsulation can be used to increase the bond strength of insert to composite.

  19. Compiler-assisted static checkpoint insertion

    Science.gov (United States)

    Long, Junsheng; Fuchs, W. K.; Abraham, Jacob A.

    1992-01-01

    This paper describes a compiler-assisted approach for static checkpoint insertion. Instead of fixing the checkpoint location before program execution, a compiler enhanced polling mechanism is utilized to maintain both the desired checkpoint intervals and reproducible checkpoint 1ocations. The technique has been implemented in a GNU CC compiler for Sun 3 and Sun 4 (Sparc) processors. Experiments demonstrate that the approach provides for stable checkpoint intervals and reproducible checkpoint placements with performance overhead comparable to a previously presented compiler assisted dynamic scheme (CATCH) utilizing the system clock.

  20. Commercial Generic Bioprocessing Apparatus Science Insert - 03

    Science.gov (United States)

    Moreno, Nancy; Stodieck, Louis; Cushing, Paula; Stowe, Mark; Hamilton, Mary Ann; Werner, Ken

    2008-01-01

    Commercial Generic Bioprocessing Apparatus Science Insert - 03 (CSI-03) is the third set of investigations in the CSI program series. The CSI program provides the K-12 community opportunities to utilize the unique microgravity environment of the International Space Station as part of the regular classroom to encourage learning and interest in science, technology, engineering and math. CSI-03 will examine the complete life cycle of the painted lady butterfly and the ability of an orb weaving spider to spin a web, eat and remain healthy in space.

  1. Phoenix's Probe Inserted in Martian Soil

    Science.gov (United States)

    2008-01-01

    The Phoenix Mars lander's robotic-arm camera took this image of the spacecraft's thermal and electrical-conductivity probe (TECP) inserted into Martian soil on day 149 of the mission. Phoenix landed on Mars' northern plains on May 25, 2008, landing. The robotic-arm camera acquired this image at 16:02:41 local solar time. The camera pointing was elevation -72.6986 degrees and azimuth 2.1093 degrees. The Phoenix mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  2. T-tube insertion for sclerotic subglottic stenosis.

    Science.gov (United States)

    Goto, Taichiro; Kato, Ryoichi

    2014-02-01

    T-tube insertion is effective treatment for subglottic stenosis, but it is generally difficult due to bending of the T-tube. In a 52-year-old woman with relapsing polychondritis, a T-tube was inserted after predilatation using Hegar dilators. We describe the details of our T-tube insertion methods for sclerotic subglottic stenosis.

  3. Effect of medial arch-heel support in inserts on reducing ankle eversion: a biomechanics study

    Directory of Open Access Journals (Sweden)

    Yung Patrick SH

    2008-02-01

    Full Text Available Abstract Background Excessive pronation (or eversion at ankle joint in heel-toe running correlated with lower extremity overuse injuries. Orthotics and inserts are often prescribed to limit the pronation range to tackle the problem. Previous studies revealed that the effect is product-specific. This study investigated the effect of medial arch-heel support in inserts on reducing ankle eversion in standing, walking and running. Methods Thirteen pronators and 13 normal subjects participated in standing, walking and running trials in each of the following conditions: (1 barefoot, and shod condition with insert with (2 no, (3 low, (4 medium, and (5 high medial arch-heel support. Motions were captured and processed by an eight-camera motion capture system. Maximum ankle eversion was calculated by incorporating the raw coordinates of 15 anatomical positions to a self-compiled Matlab program with kinematics equations. Analysis of variance with repeated measures with post-hoc Tukey pairwise comparisons was performed on the data among the five walking conditions and the five running conditions separately. Results Results showed that the inserts with medial arch-heel support were effective in dynamics trials but not static trials. In walking, they successfully reduced the maximum eversion by 2.1 degrees in normal subjects and by 2.5–3.0 degrees in pronators. In running, the insert with low medial arch support significantly reduced maximum eversion angle by 3.6 and 3.1 degrees in normal subjects and pronators respectively. Conclusion Medial arch-heel support in inserts is effective in reducing ankle eversion in walking and running, but not in standing. In walking, there is a trend to bring the over-pronated feet of the pronators back to the normal eversion range. In running, it shows an effect to restore normal eversion range in 84% of the pronators.

  4. Microbial colonization of tailed and tailless intrauterine contraceptive devices: influence of the mode of insertion in the rabbit.

    Science.gov (United States)

    Jacques, M; Olson, M E; Costerton, J W

    1986-03-01

    An experimental rabbit model was developed to study the microbial colonization of intrauterine contraceptive devices. Tailed and tailless devices were surgically inserted into into the uterus by two different routes: surgically, directly into the uterine horn, thus avoiding contact with the vaginal and cervical microfloras, or via the vagina and cervix. After 1 to 8 weeks the devices were recovered and prepared for scanning electron microscopy. The surfaces of surgically inserted devices remained uncolonized all through the experiment whereas in those inserted via the cervix microorganisms colonized the core surface as early as 2 weeks after insertion. Our data suggest that in our experimental conditions the mode of insertion appears to be the major factor influencing the microbial colonization of intrauterine contraceptive devices and that the presence of a tail does not seem to play a significant role.

  5. Acoustic Emission Detection of Macro-Cracks on Engraving Tool Steel Inserts during the Injection Molding Cycle Using PZT Sensors

    Directory of Open Access Journals (Sweden)

    Aleš Hančič

    2013-05-01

    Full Text Available This paper presents an improved monitoring system for the failure detection of engraving tool steel inserts during the injection molding cycle. This system uses acoustic emission PZT sensors mounted through acoustic waveguides on the engraving insert. We were thus able to clearly distinguish the defect through measured AE signals. Two engraving tool steel inserts were tested during the production of standard test specimens, each under the same processing conditions. By closely comparing the captured AE signals on both engraving inserts during the filling and packing stages, we were able to detect the presence of macro-cracks on one engraving insert. Gabor wavelet analysis was used for closer examination of the captured AE signals’ peak amplitudes during the filling and packing stages. The obtained results revealed that such a system could be used successfully as an improved tool for monitoring the integrity of an injection molding process.

  6. Phoenix Conductivity Probe Inserted in Martian Soil

    Science.gov (United States)

    2008-01-01

    This series of six images from the Robotic Arm Camera on NASA's Phoenix Mars Lander records the first time that the four spikes of the lander's thermal and electrical conductivity probe were inserted into Martian soil. The images were taken on July 8, 2008, during the Phoenix mission's 43rd Martian day, or sol, since landing. The insertion visible from the shadows cast on the ground on that sol was a validation test of the procedure. The spikes on the probe are about 1.5 centimeters or half an inch long. The science team will use the probe tool to assess how easily heat and electricity move through the soil from one spike to another. Such measurements can provide information about frozen or unfrozen water in the soil. The probe is mounted on the 'knuckle' of Phoenix's Robotic Arm. It has already been used for assessing water vapor in the atmosphere when it is held above the ground. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is led by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  7. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  8. Insertion of coherence requests for debugging a multiprocessor

    Science.gov (United States)

    Blumrich, Matthias A.; Salapura, Valentina

    2010-02-23

    A method and system are disclosed to insert coherence events in a multiprocessor computer system, and to present those coherence events to the processors of the multiprocessor computer system for analysis and debugging purposes. The coherence events are inserted in the computer system by adding one or more special insert registers. By writing into the insert registers, coherence events are inserted in the multiprocessor system as if they were generated by the normal coherence protocol. Once these coherence events are processed, the processing of coherence events can continue in the normal operation mode.

  9. A buffer insertion and simultaneous sizing timing optimization algorithm

    Institute of Scientific and Technical Information of China (English)

    Yin Guoli; Lin Zhenghui

    2006-01-01

    A path-based timing optimization algorithm for buffer insertion and simultaneous sizing is proposed.Firstly, candidate buffer insertion location and buffer size for each branch in a given routing path were obtained via localized timing optimization. Then, through evaluating each potential insertion against design objectives, potential optimal buffer insertion locations and sizes for the whole routing tree were determined. At last, by removing redundant buffer insertion operations which do not maximize S ( so ), given timing requirements are finally fulfilled through minimum number of buffers.

  10. Insertion-Sequence-Mediated Mutations Isolated During Adaptation to Growth and Starvation in Lactococcus lactis.

    NARCIS (Netherlands)

    Visser, de J.A.G.M.; Akkermans, A.D.L.; Hoekstra, R.F.; Vos, de W.M.

    2004-01-01

    We studied the activity of three multicopy insertion sequence (IS) elements in 12 populations of Lactococcus lactis IL1403 that evolved in the laboratory for 1000 generations under various environmental conditions (growth or starvation and shaken or stationary). Using RFLP analysis of single-clone r

  11. [Drug package inserts and the adequacy of patient's drug information].

    Science.gov (United States)

    da Silva, T; Dal-Pizzol, F; Bello, C M; Mengue, S S; Schenkel, E P

    2000-04-01

    To investigate the adequacy of the content and format of the patient information section in package inserts of commonly prescribed drugs at the internal medicine service of a school hospital. Forty eight package inserts were collected from six pharmacies of the city of Porto Alegre in June 1998. The presence of mandatory notification and other information required by Brazilian laws that regulate inserts content was examined. No one package inserts contained all the notification required by law. Warnings about medication storage and expiration date were the most frequently information found in package inserts analyzed. Important information for the drug user was not presented in package inserts analyzed, limiting the purpose of inserts as an instrument for patient education.

  12. Polymorphic Alu insertions among Mayan populations.

    Science.gov (United States)

    Herrera, R J; Rojas, D P; Terreros, M C

    2007-01-01

    The Mayan homeland within Mesoamerica spans five countries: Belize, El Salvador, Guatemala, Honduras and Mexico. There are indications that the people we call the Maya migrated from the north to the highlands of Guatemala as early as 4000 B.C. Their existence was village-based and agricultural. The culture of these Preclassic Mayans owes much to the earlier Olmec civilization, which flourished in the southern portion of North America. In this study, four different Mayan groups were examined to assess their genetic variability. Ten polymorphic Alu insertion (PAI) loci were employed to ascertain the genetic affinities among these Mayan groups. North American, African, European and Asian populations were also examined as reference populations. Our results suggest that the Mayan groups examined in this study are not genetically homogeneous.

  13. Stabilization of insertion electrodes for lithium batteries.

    Energy Technology Data Exchange (ETDEWEB)

    Thackeray, M. M.

    1998-09-03

    This paper discusses the techniques that are being employed to stabilize LiMn{sub 2}O{sub 4} spinel and composite Li{sub x}MnO{sub 2} positive electrodes. The critical role that spinel domains play in stabilizing these electrodes for operation at both 4 V and 3 V is highlighted. The concept of using an intermetallic electrode MM{prime} where M is an active alloying element and M{prime} is an inactive element (or elements) is proposed as an alternative negative electrode (to carbon) for lithium-ion cells. An analogy to metal oxide insertion electrodes, such as MnO{sub 2}, in which Mn is the electrochemically active ion and O is the inactive ion, is made. Performance data are given for the copper-tin electrode system, which includes the intermetallic phases eta-Cu{sub 6}Sn{sub 5} and Li{sub 2}CuSn.

  14. Phoenix Conductivity Probe Inserted into Martian Soil

    Science.gov (United States)

    2008-01-01

    NASA's Phoenix Mars Lander inserted the four needles of its thermal and conductivity probe into Martian soil during the 98th Martian day, or sol, of the mission and left it in place until Sol 99 (Sept. 4, 2008). The Robotic Arm Camera on Phoenix took this image on the morning of Sol 99 while the probe's needles were in the ground. The science team informally named this soil target 'Gandalf.' The thermal and conductivity probe measures how fast heat and electricity move from one needle to an adjacent one through the soil or air between the needles. Conductivity readings can be indicators about water vapor, water ice and liquid water. The probe is part of Phoenix's Microscopy, Electrochemistry and Conductivity suite of instruments. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  15. Impact of Orthodontic Decompensation on Bone Insertion

    Directory of Open Access Journals (Sweden)

    Fabio Pinto Guedes

    2014-01-01

    Full Text Available There has always been concern in determining the relationship between orthodontic tooth movement and the consequent biological costs to the periodontium and tooth root. The possibility of evaluating the tooth and bone morphology by CBCT allows more accurate analysis of qualitative and quantitative aspects of these processes. This paper presents a case report of a 20-year-old male patient with Class III malocclusion and hyperdivergent facial pattern, who was surgically treated. A significant amount of labial movement of mandibular incisors was performed during orthodontic treatment before surgery. CBCT was used for evaluation of buccal and lingual bone plates before and after tooth decompensation. The changes in the bone insertion level of maxillary and mandibular incisors in the present case encourage a reflection on the treatment protocol in individuals with dentoskeletal discrepancies.

  16. Intramolecular hydroxycarbene C–H-insertion: The curious case of (o-methoxyphenylhydroxycarbene

    Directory of Open Access Journals (Sweden)

    Dennis Gerbig

    2010-11-01

    Full Text Available The first C–H insertion of a hydroxycarbene species in the gas phase has been observed experimentally by means of high vacuum flash pyrolysis (HVFP and subsequent matrix isolation: (o-Methoxyphenylglyoxylic acid gives non-isolable (o-methoxyphenylhydroxycarbene upon pyrolysis at 600 °C, which rapidly inserts into the methyl C–H bond. The insertion product, 2,3-dihydrobenzofuran-3-ol, was trapped in an excess of Ar at 11 K and characterized by infrared spectroscopy. The insertion process kinetically outruns the alternative [1,2]H-tunneling reaction to o-anisaldehyde, a type of reaction observed for other hydroxycarbenes. Traces of the dehydration product, benzo[b]furan, were also detected. The potential energy hypersurface including the insertion and hydrogen migration processes was computed at the all-electron coupled-cluster level of theory encompassing single and double substitutions and perturbatively included triple excitations [AE-CCSD(T] in conjunction with a correlation-consistent double-ζ basis set (cc-pVDZ by utilizing density functional theory (DFT optimized geometries (M06-2X/cc-pVDZ with zero-point vibrational energy (ZPVE corrections. Exchange of the methoxy for a trifluoromethoxy group successfully prevents insertion and (o-trifluoromethoxybenzaldehyde is produced instead; however, the carbene cannot be observed under these conditions. Thermal decomposition of (o-methoxyphenylglyoxylic acid in refluxing xylenes does not give the insertion product but yields o-anisaldehyde. This unanticipated outcome can be rationalized by protonation of the hydroxycarbene intermediate leading to the tautomeric formyl group. Thermochemical computations at M06-2X/cc-pVDZ in conjunction with a self-consistent solvent reaction field model support this suggested reaction pathway.

  17. Regulatory perspective on incomplete control rod insertions

    Energy Technology Data Exchange (ETDEWEB)

    Chatterton, M.

    1997-01-01

    The incomplete control rod insertions experienced at South Texas Unit 1 and Wolf Creek are of safety concern to the NRC staff because they represent potential precursors to loss of shutdown margin. Even before it was determined if these events were caused by the control rods or by the fuel there was an apparent correlation of the problem with high burnup fuel. It was determined that there was also a correlation between high burnup and high drag forces as well as with rod drop time histories and lack of rod recoil. The NRC staff initial actions were aimed at getting a perspective on the magnitude of the problem as far as the number of plants and the amount of fuel that could be involved, as well as the safety significance in terms of shutdown margin. As tests have been performed and data has been analyzed the focus has shifted more toward understanding the problem and the ways to eliminate it. At this time the staff`s understanding of the phenomena is that it was a combination of factors including burnup, power history and temperature. The problem appears to be very sensitive to these factors, the interaction of which is not clearly understood. The model developed by Westinghouse provides a possible explanation but there is not sufficient data to establish confidence levels and sensitivity studies involving the key parameters have not been done. While several fixes to the problem have been discussed, no definitive fixes have been proposed. Without complete understanding of the phenomena, or fixes that clearly eliminate the problem the safety concern remains. The safety significance depends on the amount of shutdown margin lost due to incomplete insertion of the control rods. Were the control rods to stick high in the core, the reactor could not be shutdown by the control rods and other means such as emergency boration would be required.

  18. Insertion Testing of Polyethylene Glycol Microneedle Array into Cultured Human Skin with Biaxial Tension

    Science.gov (United States)

    Takano, Naoki; Tachikawa, Hiroto; Miyano, Takaya; Nishiyabu, Kazuaki

    Aiming at the practical use of polyethylene glycol (PEG) microneedles for transdermal drug delivery system (DDS), a testing apparatus for their insertion into cultured human skin has been developed. To simulate the variety of conditions of human skin, biaxial tension can be applied to the cultured human skin. An adopted testing scheme to apply and control the biaxial tension is similar to the deep-draw forming technique. An attention was also paid to the short-time setup of small, thin and wet cultured skin. One dimensional array with four needles was inserted and influence of tension was discussed. It was found that tension, deflection of skin during insertion and original curvature of skin are the important parameters for microneedles array design.

  19. Computational study of alkynes insertion into metal-hydride bonds catalyzed by bimetallic complexes.

    Science.gov (United States)

    Di Tommaso, Stefania; Tognetti, Vincent; Sicilia, Emilia; Adamo, Carlo; Russo, Nino

    2010-11-01

    Density Functional Theory investigations on the insertion mechanism of phenylacetylene into metal-hydride bonds in bimetallic (Pt,Os) catalysts have been carried out. The results obtained have been also compared with the non-reactive monometallic (Os-based) system, to elucidate the cooperative effects and to explain the observed absence of reactivity. The identified reaction path involves phenylacetylene coordination followed by the insertion into the metal-hydride bond, leading to the formation of the experimentally observed products. Both steps do not require large energies compatible with the experimental conditions. The comparison with the reaction path for the monometallic species gives some hints on the cooperative effects due to the presence of the second metal which is related to its role in the CO release for creating a coordination site for phenylacetylene and not in the insertion energetics. The calculations provide a detailed analysis of the reaction complexity and provide a rationale for the efficiency of the process.

  20. Posterior cruciate ligament's tibial insertions: topographic anatomy and morphometric study

    Directory of Open Access Journals (Sweden)

    Julio Cesar Gali

    2013-06-01

    Full Text Available OBJECTIVE: To provide anatomical and morphometric basis of the posterior cruciate ligament's tibial insertions in order to assist the creation of anatomical tibial tunnels, in the ligament surgical reconstruction. MATERIAL AND METHODS: The topographic anatomy and morphometry of the posterior cruciate ligament's anterolateral and posteromedial bundles' tibial insertions were analyzed in 24 anatomical knee pieces. The pieces were photographed by a digital camera and the images obtained were studied by the software ImageJ, where the bundles' insertion areas were measured in square millimeters, and the length of structures and the distances between significant points were measured in millimeters. RESULTS: In 54.2% of the knees the insertion' shape was concave; in most pieces (41.6% the form of insertion was oval. The average posterior cruciate ligament's tibial insertion total area was 88.33 ± 21.66 mm2; the average anterolateral bundle's tibial insertion area was 46.79 ± 14.10 mm2 and it was 41.54 ± 9.75 mm2 for the posteromedial bundle. CONCLUSIONS: The anterolateral bundle has a tibial insertion area larger than the posteromedial bundle; the insertion areas of those bundles in our study, were smaller than the ones found in the literature. The variations in the posterior cruciate ligament's tibial insertion area suggest that there should be an indication for anatomical reconstructions of this ligament using single or double tibial tunnels according to individual characteristics.

  1. Test of the ITER TF Insert and Central Solenoid Model Coil

    Energy Technology Data Exchange (ETDEWEB)

    Martovetsky, N; Takayasu, M; Minervini, J; Isono, T; Sugimoto, M; Kato, T; Kawano, K; Koisumi, N; Nakajima, H; Nunova, Y; Okuno, K; Tsuji, H; Oshikiri, M; Mitchell, N; Takahashi, Y; Egorov, S; Rodin, I; Zanino, R; Savoldi, L

    2002-07-29

    The Central Solenoid Model Coil (CSMC) was designed and built by ITER collaboration between the European Union, Japan, Russian Federation and the United States in 1993-2001. Three heavily instrumented insert coils have been also built for testing in the background field of the CSMC to cover a wide operational space. The TF Insert was designed and built by the Russian Federation to simulate the conductor performance under the ITER TF coil conditions. The TF Insert Coil was tested in the CSMC Test Facility at the Japan Atomic Energy Research Institute, Naka, Japan in September-October 2001. Some measurements were performed also on the CSMC to study effects of electromagnetic and cooldown cycles. The TF Insert coil was charged successfully, without training, in the background field of the CSMC to the design current of 46 kA at 13 T peak field. The TF Insert met or exceeded all design objectives, however some interesting results require thorough analyses. This paper presents the overview of main results of the testing--magnet critical parameters, ac losses, joint performance, effect of cycles on performance, quench and thermo-hydraulic characteristics and some results of the post-test analysis.

  2. Nerve distributions in insertional Achilles tendinopathy - a comparison of bone, bursae and tendon.

    Science.gov (United States)

    Andersson, Gustav; Backman, Ludvig J; Christensen, Jens; Alfredson, Håkan

    2017-03-01

    In a condition of pain in the Achilles tendon insertion there are multiple structures involved, such as the Achilles tendon itself, the retrocalcaneal bursa and a bony protrusion at the calcaneal tuberosity called Haglund's deformity. The innervation patterns of these structures are scarcely described, and the subcutaneous calcaneal bursa is traditionally not considered to be involved in the pathology. This study aimed at describing the innervation patterns of the four structures described above to provide a better understanding of possible origins of pain at the Achilles tendon insertion. Biopsies were taken from 10 patients with insertional Achilles tendinopathy, which had pathological changes in the subcutaneous and retrocalcaneal bursae, a Haglund deformity and Achilles tendon tendinopathy as verified by ultrasound. The biopsies were stained using immunohistochemistry in order to delineate the innervation patterns in the structures involved in insertional Achilles tendinopathy. Immunohistochemical examinations found that the subcutaneous bursa scored the highest using a semi-quantitative evaluation of the degree of innervation when compared to the retrocalcaneal bursa, the Achilles tendon, and the calcaneal bone. These findings suggest that the subcutaneous bursa, which is traditionally not included in surgical treatment, may be a clinically important factor in insertional Achilles tendinopathy.

  3. The Effect of Windings on ADSL Transformer Insertion Losses

    Institute of Scientific and Technical Information of China (English)

    JIANG Xiao-na; LAN Zhong-wen; CHEN Sheng-ming; ZHANG Huai-wu; SU Hua

    2007-01-01

    Insertion loss (IL) is one of the important parameters of asymmetrical digital subscriber loop (ADSL) transformers. In different frequency bands, the factors that affect insertion loss are different. Windings mainly affect insertion loss in mid and high frequency bands.The effects of winding ways, winding wire diameter and winding turns on insertion loss were discussed. The presented experiment shows that the insertion loss of an ADSL transformer could be under 0.4 dB in mid frequency band when the winding is 30 turns, in which the ADSL transformer satisfies the requirement of total harmonic distortion (THD). Our experiments also show that the sandwich winding structure is better than the side by side winding structure and the twisted-pair winding structure, and the increase of winding diameter is one means to reduce insertion losses of an ADSL transformer in mid frequency band.

  4. Ocular inserts - Advancement in therapy of eye diseases

    Directory of Open Access Journals (Sweden)

    Anita Kumari

    2010-01-01

    Full Text Available The ocular insert represents a significant advancement in the therapy of eye disease. Ocular inserts are defined as sterile, thin, multilayered, drug-impregnated, solid or semisolid consistency devices placed into the cul-de-sac or conjuctival sac, whose size and shape are especially designed for ophthalmic application. They are composed of a polymeric support that may or may not contain a drug. The drug can later be incorporated as dispersion or a solution in the polymeric support. They offer several advantages as increased ocular residence and sustained release of medication into the eye. The insert includes a body portion sized to position within a lachrymal canaliculus of the eyelid. The inserts are classified according to their solubility as insoluble, soluble, or bioerodible inserts. The release of drug from the insert depends upon the diffusion, osmosis, and bioerosion of the drug, and this article is an attempt to present a brief about this newer drug delivery system.

  5. Comparison of large-insert, small-insert and pyrosequencing libraries for metagenomic analysis

    OpenAIRE

    2012-01-01

    The development of DNA sequencing methods for characterizing microbial communities has evolved rapidly over the past decades. To evaluate more traditional, as well as newer methodologies for DNA library preparation and sequencing, we compared fosmid, short-insert shotgun and 454 pyrosequencing libraries prepared from the same metagenomic DNA samples. GC content was elevated in all fosmid libraries, compared with shotgun and 454 libraries. Taxonomic composition of the different libraries sugge...

  6. Modeling of Porous Insertion Electrodes with Liquid Electrolyte

    DEFF Research Database (Denmark)

    West, Keld; Jacobsen, Torben; Atlung, Sven

    1982-01-01

    The dynamics of porous insertion electrodes during charge or discharge is described by a simplified mathematicalmodel, accounting for the coupled transport in electrode and electrolyte phases. A numerical method to evaluate theresponse of this model to either controlled potential or controlled cu...... is a consequence of the mobility of the ions not inserted, hence the performance of this type of electrode isoptimized by choosing electrolytes with transport number as close to unity as possible for the inserted ion....

  7. A CRITICAL APPRAISAL OF PACKAGE INSERTS IN INDIA

    Directory of Open Access Journals (Sweden)

    Makbool Ali M.

    2016-06-01

    Full Text Available formation is a Package Insert. It is a printed leaflet that contains information based on regulatory guidelines for the safe and effective use of a drug. Incomplete and incorrect product information may have serious consequences including disability or death. In India, the concept of package insert is governed by the Drugs and Cosmetics Act (1940 and Rules (1945. Keeping this in mind, this study was designed to assess the presentation and completeness of drug information provided in the currently available package inserts for allopathic drugs in India. AIM To evaluate the presentation and completeness of drug information provided in the currently available package inserts for allopathic drugs in India. OBJECTIVES To evaluate drug information in package inserts according to headings mentioned in Section 6.2 and 6.3 of Schedule D, Drugs and Cosmetics Rules, 1945. MATERIAL AND METHODS Package inserts accompanying allopathic medicines were obtained from a drug store and three pharmacies around a tertiary care centre in Western India on request over a 1-month period. The package inserts were included in the study and analysed for the presentation and completeness of information according to the headings mentioned in Section 6.2 and Section 6.3 of Schedule D, The Drugs and Cosmetics Rules, 1945. RESULTS 110 package inserts were analysed in the study. None of the reviewed package insert contained all the sections as required by the Drugs and Cosmetic Rules. CONCLUSION To avoid medication errors due to deficits in drug information in package inserts, tighter monitoring of package inserts by regulatory authorities is recommended. Steps should be taken to ensure that the information in the package inserts follows a standard layout for easy and convenient comprehension.

  8. Risk factors for development of complication following peripherally inserted central

    OpenAIRE

    Hakan Aydın; Gülsen Korfalı; Suna Gören; Esra Mercanoğlu Efe; Bachri Ramadan Moustafa; Tolga Yazıcı

    2014-01-01

    Objectives: Peripherally inserted central venous catheters (PICCs) are inserted into central veins through the upper extremity veins. In this retrospective study, we aimed to evaluate PICC procedures, related complications, their causes and factors influencing the success of the procedure during anaesthesia Methods: ‘Central Venous Catheterization Forms’ filled out for 850 patients in whom a PICC was inserted by residents during general anaesthesia between November 2009 and March 2013 in t...

  9. Insertion torque versus mechanical resistance of mini-implants inserted in different cortical thickness

    Science.gov (United States)

    Santos, Renata de Faria; Ruellas, Antonio Carlos de Oliveira; Fernandes, Daniel Jogaib; Elias, Carlos Nelson

    2014-01-01

    Objective This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI) (Conexão Sistemas de PróteseT), as well as to analyze surface morphology. Methods Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal neck of MIs. Surface morphology was assessed by scanning electron microscopy (SEM) before and after the mechanical tests. Results Values of mechanical resistance to fracture (22.14 N.cm and 54.95 N.cm) were higher and statistically different (P 0.05) to torsional fracture in the tip of MI (22.14 N.cm) when 3 mm cortical thickness (16.11 N.cm) and dense bone (23.95 N.cm) were used. Torsional fracture of the transmucosal neck (54.95 N.cm) was higher and statistically different (P implants tested presented adequate surface morphology. The resistance of mini-implants to fracture safely allows placement in 1 and 2-mm cortical thickness. However, in 3-mm cortical thickness and dense bones, pre-drilling with a bur is recommended before insertion. PMID:25162571

  10. Threaded insert for compact cryogenic-capable pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa-Loza, Francisco; Ross, Timothy O.; Switzer, Vernon A.; Aceves, Salvador M.; Killingsworth, Nicholas J.; Ledesma-Orozco, Elias

    2015-06-16

    An insert for a cryogenic capable pressure vessel for storage of hydrogen or other cryogenic gases at high pressure. The insert provides the interface between a tank and internal and external components of the tank system. The insert can be used with tanks with any or all combinations of cryogenic, high pressure, and highly diffusive fluids. The insert can be threaded into the neck of a tank with an inner liner. The threads withstand the majority of the stress when the fluid inside the tank that is under pressure.

  11. Threaded insert for compact cryogenic-capable pressure vessels

    Science.gov (United States)

    Espinosa-Loza, Francisco; Ross, Timothy O.; Switzer, Vernon A.; Aceves, Salvador M.; Killingsworth, Nicholas J.; Ledesma-Orozco, Elias

    2015-06-16

    An insert for a cryogenic capable pressure vessel for storage of hydrogen or other cryogenic gases at high pressure. The insert provides the interface between a tank and internal and external components of the tank system. The insert can be used with tanks with any or all combinations of cryogenic, high pressure, and highly diffusive fluids. The insert can be threaded into the neck of a tank with an inner liner. The threads withstand the majority of the stress when the fluid inside the tank that is under pressure.

  12. Insertional protein engineering for analytical molecular sensing

    Directory of Open Access Journals (Sweden)

    Arís Anna

    2006-04-01

    Full Text Available Abstract The quantitative detection of low analyte concentrations in complex samples is becoming an urgent need in biomedical, food and environmental fields. Biosensors, being hybrid devices composed by a biological receptor and a signal transducer, represent valuable alternatives to non biological analytical instruments because of the high specificity of the biomolecular recognition. The vast range of existing protein ligands enable those macromolecules to be used as efficient receptors to cover a diversity of applications. In addition, appropriate protein engineering approaches enable further improvement of the receptor functioning such as enhancing affinity or specificity in the ligand binding. Recently, several protein-only sensors are being developed, in which either both the receptor and signal transducer are parts of the same protein, or that use the whole cell where the protein is produced as transducer. In both cases, as no further chemical coupling is required, the production process is very convenient. However, protein platforms, being rather rigid, restrict the proper signal transduction that necessarily occurs through ligand-induced conformational changes. In this context, insertional protein engineering offers the possibility to develop new devices, efficiently responding to ligand interaction by dramatic conformational changes, in which the specificity and magnitude of the sensing response can be adjusted up to a convenient level for specific analyte species. In this report we will discuss the major engineering approaches taken for the designing of such instruments as well as the relevant examples of resulting protein-only biosensors.

  13. Polyembolokoilamania: Self-insertion of transistor radio antenna in male urethra

    Directory of Open Access Journals (Sweden)

    Jibril Oyekunle Bello

    2013-01-01

    Full Text Available Though self-insertion of a foreign body in the male urethra is an infrequent urologic emergency, a weird variety of self-inserted foreign bodies have been reported. Most of these are attributed to autoerotic stimulation, a consequence of mental illness or the result of drug intoxication. We report an unusual case of a 65-year-old African man who self-inserted a broken transistor radio antenna into his urethra to serve as an improvised ′itchstick′ to ease a bothersome itchy urethral condition. The foreign body subsequently migrated proximally out of reach. He presented a week after with urethral bleeding following nocturnal penile erections and we describe his evaluation and the challenge of retrieval. The reasons for self-inserting objects into the urethra may be as varied as the foreign bodies themselves and may include objects being used as an improvised ′itchstick′ for itchy urethral conditions. The urologist′s creative tendencies will often be required in safely removing these objects.

  14. Characterization of vibration and acoustic noise in a gradient-coil insert.

    Science.gov (United States)

    Yao, G Z; Mechefske, C K; Rutt, B K

    2004-09-01

    High-speed switching of current in gradient coils within high magnetic field strength magnetic resonance imaging (MRI) scanners results in high acoustic sound pressure levels (SPL) in and around these machines. To characterize the vibration properties as well as the acoustic noise properties of the gradient coil, a finite-element (FE) model was developed using the dimensional design specifications of an available gradient-coil insert and the concentration of the copper windings in the coil. This FE model was then validated using experimentally collected vibration data. A computational acoustic noise model was then developed based on the validated FE model. The validation of the finite-element analysis results was done using experimental modal testing of the same gradient coil in a free-free state (no boundary constraints). Based on the validated FE model, boundary conditions (supports) were added to the model to simulate the operating condition when the gradient-coil insert is in place in an MRI machine. Vibration analysis results from the FE model were again validated through experimental vibration testing with the gradient-coil insert installed in the MRI scanner and excited using swept sinusoidal time waveforms. The simulation results from the computational acoustic noise model were also validated through experimental noise measurement from the gradient-coil insert in the MRI scanner using swept sinusoidal time waveform inputs. Comparisons show that the FE model predicts the vibration properties and the computational acoustic noise model predicts the noise characteristic properties extremely accurately.

  15. Clinical information in drug package inserts in India

    Directory of Open Access Journals (Sweden)

    Shivkar Y

    2009-01-01

    Full Text Available Background: It is widely recognized that accurate and reliable product information is essential for the safe and effective use of medications. Pharmaceutical companies are the primary source of most drug information, including package inserts. Package inserts are printed leaflets accompanying marketed drug products and contain information approved by the regulatory agencies. Studies on package inserts in India, in 1996, had shown that crucial information was often missing and they lacked uniformity. Aim: To assess the presentation and completeness of clinically important information provided in the currently available package inserts in India. Materials and Methods: Package inserts accompanying allopathic drug products marketed by pharmaceutical companies in India were collected. These package inserts were analyzed for the content of clinically important information in various sections. Statistical Analysis: The results were expressed as absolute numbers and percentages. Results: Preliminary analyses revealed that most package inserts did contain information under headings, such as, therapeutic indications, contraindications, undesirable effects, etc., listed in the Drugs and Cosmetics Rules 1945. The findings indicated considerable improvement in package inserts since 1996. However, on critical evaluation it was revealed that clinically important information was not well presented and was often incomplete. Information with regard to pediatric and geriatric use was present in only 44% and 13% of the package inserts, respectively. Only five of the inserts had information on the most frequent adverse drug reactions associated with the drug. Also, information on interactions and overdosage was often missing. Conclusion: Although the package inserts appear to have improved over the past decade there is still a definite need to further refine the clinical information contained, to minimize the risks to patients. This could be brought about by self

  16. Simultaneous PET/MR imaging with a radio frequency-penetrable PET insert.

    Science.gov (United States)

    Grant, Alexander M; Lee, Brian J; Chang, Chen-Ming; Levin, Craig S

    2017-01-01

    A brain sized radio frequency (RF)-penetrable PET insert has been designed for simultaneous operation with MRI systems. This system takes advantage of electro-optical coupling and battery power to electrically float the PET insert relative to the MRI ground, permitting RF signals to be transmitted through small gaps between the modules that form the PET ring. This design facilitates the use of the built-in body coil for RF transmission and thus could be inserted into any existing MR site wishing to achieve simultaneous PET/MR imaging. The PET detectors employ nonmagnetic silicon photomultipliers in conjunction with a compressed sensing signal multiplexing scheme, and optical fibers to transmit analog PET detector signals out of the MRI room for decoding, processing, and image reconstruction. The PET insert was first constructed and tested in a laboratory benchtop setting, where tomographic images of a custom resolution phantom were successfully acquired. The PET insert was then placed within a 3T body MRI system, and tomographic resolution/contrast phantom images were acquired both with only the B0 field present, and under continuous pulsing from different MR imaging sequences. The resulting PET images have comparable contrast-to-noise ratios (CNR) under all MR pulsing conditions: The maximum percent CNR relative difference for each rod type among all four PET images acquired in the MRI system has a mean of 14.0 ± 7.7%. MR images were successfully acquired through the RF-penetrable PET shielding using only the built-in MR body coil, suggesting that simultaneous imaging is possible without significant mutual interference. These results show promise for this technology as an alternative to costly integrated PET/MR scanners; a PET insert that is compatible with any existing clinical MRI system could greatly increase the availability, accessibility, and dissemination of PET/MR. © 2016 American Association of Physicists in Medicine.

  17. J-tube technique for double-j stent insertion during laparoscopic upper urinary tract surgical procedures.

    Science.gov (United States)

    Kim, Hyung Suk; Lee, Byung Ki; Jung, Jin-Woo; Lee, Jung Keun; Byun, Seok-Soo; Lee, Sang Eun; Jeong, Chang Wook

    2014-11-01

    Double-J stent insertion has been generally performed during laparoscopic upper urinary tract (UUT) surgical procedures to prevent transient urinary tract obstruction and postoperative flank pain from ureteral edema and blood clots. Several restrictive conditions that make this procedure difficult and time consuming, however, include the coiled distal ends of the flexible Double-J stent and the limited bending angle of the laparoscopic instruments. To overcome these limitations, we devised a Double-J stent insertion method using the new J-tube technique. Between July 2011 and May 2013, Double-J stents were inserted using the J-tube technique in 33 patients who underwent a laparoscopic UUT surgical procedure by a single surgeon. The mean stent placement time was 4.8±2.7 minutes, and there were no intraoperative complications. In conclusion, the J-tube technique is a safe and time-saving method for Double-J stent insertion during laparoscopic surgical procedures.

  18. Velamentous Cord Insertion in a Singleton Pregnancy: An Obscure Cause of Emergency Cesarean—A Case Report

    Directory of Open Access Journals (Sweden)

    Juliana Rocha

    2012-01-01

    Full Text Available Approximately 2% of low-risk pregnant women still require an emergency Cesarean section after the onset of labor. Because it is likely that half of these cases are associated with placental and umbilical cord abnormalities, it is thought that prenatal detection of such abnormalities would reduce the number of emergency cesarean sections in low-risk women. Velamentous cord insertion is an abnormal cord insertion in which the umbilical vessels diverge as they traverse between the amnion and chorion before reaching the placenta. With a reported incidence of 1% in singleton pregnancies, it has been associated with several obstetric complications. This condition has been diagnosed by ultrasonography with a sensitivity of 67% and specificity of 100% in the second trimester. The present case highlights the importance of the systematic assessment of the placental cord insertion site at routine obstetric ultrasound and the potential of identifying pregnancies with velamentous insertion and, therefore, those at risk for obstetric complications.

  19. Load beam unit replaceable inserts for dry coal extrusion pumps

    Science.gov (United States)

    Saunders, Timothy; Brady, John D.

    2012-11-13

    A track assembly for a particulate material extrusion pump according to an exemplary aspect of the present disclosure includes a link assembly with a roller bearing. An insert mounted to a load beam located such that the roller bearing contacts the insert.

  20. Enhanced citrate production through gene insertion in Aspergillus niger

    DEFF Research Database (Denmark)

    Jongh, Wian de; Nielsen, Jens

    2007-01-01

    The effect of inserting genes involved in the reductive branch of the tricarboxylic acid (TCA) cycle on citrate production by Aspergillus niger was evaluated. Several different genes were inserted individually and in combination, i.e. malate dehydrogenase (mdh2) from Saccharomyces cerevisiae, two...

  1. 17 CFR 240.12b-14 - Riders; inserts.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Riders; inserts. 240.12b-14 Section 240.12b-14 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED... Exchange Act of 1934 Formal Requirements § 240.12b-14 Riders; inserts. Riders shall not be used. If...

  2. 17 CFR 270.8b-14 - Riders; inserts.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Riders; inserts. 270.8b-14 Section 270.8b-14 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) RULES AND REGULATIONS, INVESTMENT COMPANY ACT OF 1940 § 270.8b-14 Riders; inserts. Riders shall not be...

  3. 17 CFR 260.7a-20 - Riders; inserts.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Riders; inserts. 260.7a-20...) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Formal Requirements § 260.7a-20 Riders; inserts. Riders shall not be used. If the application, statement or report is typed on a printed form, and...

  4. Tube thoracostomy: Increased angle of insertion is associated with complications.

    Science.gov (United States)

    Hernandez, Matthew C; Laan, Danuel V; Zimmerman, Stacey L; Naik, Nimesh D; Schiller, Henry J; Aho, Johnathon M

    2016-08-01

    Tube thoracostomy (TT), considered a routine procedure, has significant complications. Current recommendations for placement rely on surface anatomy. There is no information to guide operators regarding angle of insertion relative to chest wall. We aim to determine if angle of insertion is associated with complications of TT. We performed a retrospective review of adult trauma patients who necessitated TT at a Level I trauma center over a 2-year period (January 2012 to December 2013). Tube thoracostomies performed intraoperatively or using radiological guidance were excluded. Thoracic anteroposterior or posteroanterior radiographs were reviewed to determine the angle of insertion of TT relative to the thoracic wall. A previously validated classification method was used to categorize complications. Descriptive and univariate statistics were used to compare angle of insertion and complicated versus uncomplicated TT. Review identified 154 patients who underwent a total of 246 TT placed for emergent trauma. All patients had a postprocedural chest x-ray. We identified 90 complications (37%) over the study period. One hundred forty-four of the TTs reviewed had an angle of insertion less than 45 degrees of which there were 27 complications (19%). One hundred two of the TTs had an angle greater than 45 degrees and 63 complications (62%); p thoracostomy insertion is inherently dangerous. Placement of TT using a higher angle of insertion greater than 45 degrees is associated with increased complications. Further prospective studies quantifying TT angle of insertion on outcomes are needed. Therapeutic study, level IV.

  5. Macroscopic and microscopic observations of needle insertion into gels

    NARCIS (Netherlands)

    Veen, van Youri R.J.; Jahya, Alex; Misra, Sarthak

    2012-01-01

    Needle insertion into soft tissue is one of the most common medical interventions. This study provides macroscopic and microscopic observations of needle–gel interactions. A gelatin mixture is used as a soft-tissue simulant. For the macroscopic studies, system parameters, such as insertion velocity,

  6. Analysis of the Sherlock II tip location system for inserting peripherally inserted central venous catheters.

    Science.gov (United States)

    Lelkes, Valdis; Kumar, Abhishek; Shukla, Pratik A; Contractor, Sohail; Rutan, Thomas

    2013-01-01

    Peripherally inserted central catheters (PICCs) are frequently placed at the bedside. The purpose of our study was to evaluate the efficacy of the Sherlock II tip location system (Bard Access Systems, Salt Lake City, UT), which offers electromagnetic detection of the PICC tip to assist the operator in guiding the tip to a desired location. We performed a retrospective review of patients who had a bedside PICC using the Sherlock II tip location system. Three hundred seventy-five of 384 patients (97.7%) had the catheter tip positioned appropriately. Our results suggest that the Sherlock II tip location system is an efficacious system for bedside PICC placement.

  7. Turbine airfoil having near-wall cooling insert

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Jr., Nicholas F.; Wiebe, David J.

    2017-09-12

    A turbine airfoil is provided with at least one insert positioned in a cavity in an airfoil interior. The insert extends along a span-wise extent of the turbine airfoil and includes first and second opposite faces. A first near-wall cooling channel is defined between the first face and a pressure sidewall of an airfoil outer wall. A second near-wall cooling channel is defined between the second face and a suction sidewall of the airfoil outer wall. The insert is configured to occupy an inactive volume in the airfoil interior so as to displace a coolant flow in the cavity toward the first and second near-wall cooling channels. A locating feature engages the insert with the outer wall for supporting the insert in position. The locating feature is configured to control flow of the coolant through the first or second near-wall cooling channel.

  8. Welding of titanium and stainless steel using the composite insert

    Science.gov (United States)

    Cherepanov, A. N.; Mali, V. I.; Orishich, A. M.; Malikov, A. G.; Drozdov, V. O.; Malyutina, Y. N.

    2016-11-01

    The paper concerns the possibility of obtaining a lasting permanent joint of dissimilar metals: technically pure titanium and stainless steel using laser welding and an intermediate composite insert. The insert was a four-layer composition of plates of steel, copper, niobium, and titanium welded by explosion. The material layers used in the insert prevented the molten steel and titanium from mixing, which excluded the formation of brittle intermetallic compounds, such as FeTi and Fe2Ti. The optimization of explosion welding parameters provided a high quality of the four-layer composition and the absence of defects in the area of the joint of insert plates. The results of strength tests showed that values of the ultimate strength and yield of the permanent joint with the composite insert welded by explosion are comparable to the strength characteristics of titanium.

  9. Smart structures for shock wave attenuation using ER inserts

    Science.gov (United States)

    Kim, Jaehwan; Kim, Jung-Yup; Choi, Seung-Bok; Kim, Kyung-Su

    2001-08-01

    This Paper demonstrates the possibility of shock wave attenuation propagating through a smart structure that incorporates ER insert. The wave transmission of ER inserted beam is theoretically derived using Mead & Markus model and the theoretical results are compared with the finite element analysis results. To experimentally verify the shock wave attenuation, ER insert in an aluminum plate is made and two piezoceramic disks are used as transmitter and receiver of the wave. The transmitter sends a sine pulse signal such that a component of shock wave travels through the plate structure and the receiver gets the transmitted wave signal. Wave propagation of the ER insert can be adjusted by changing the applied electric field on the ER insert. Details of the experiment are addressed and the possibility of shock wave attenuation is experimentally verified. This kind of smart structure can be used for warship and submarine hull structures to protect fragile and important equipment.

  10. Experimental investigation of the noise reduction of supersonic exhaust jets with fluidic inserts

    Science.gov (United States)

    Powers, Russell William Walter

    The noise produced by the supersonic, high temperature jets that exhaust from military aircraft is becoming a hazard to naval personnel and a disturbance to communities near military bases. Methods to reduce the noise produced from these jets in a practical full-scale environment are difficult. The development and analysis of distributed nozzle blowing for the reduction of radiated noise from supersonic jets is described. Model scale experiments of jets that simulate the exhaust jets from typical low-bypass ratio military jet aircraft engines during takeoff are performed. Fluidic inserts are created that use distributed blowing in the divergent section of the nozzle to simulate mechanical, hardwall corrugations, while having the advantage of being an active control method. This research focuses on model scale experiments to better understand the fluidic insert noise reduction method. Distributed blowing within the divergent section of the military-style convergent divergent nozzle alters the shock structure of the jet in addition to creating streamwise vorticity for the reduction of mixing noise. Enhancements to the fluidic insert design have been performed along with experiments over a large number of injection parameters and core jet conditions. Primarily military-style round nozzles have been used, with preliminary measurements of hardwall corrugations and fluidic inserts in rectangular nozzle geometries also performed. It has been shown that the noise reduction of the fluidic inserts is most heavily dependent upon the momentum flux ratio between the injector and core jet. Maximum reductions of approximately 5.5 dB OASPL have been observed with practical mass flow rates and injection pressures. The first measurements with fluidic inserts in the presence of a forward flight stream have been performed. Optimal noise reduction occurs at similar injector parameters in the presence of forward flight. Fluidic inserts in the presence of a forward flight stream were

  11. Comparison of dexmedetomidine combined with propofol Vs fentanyl combined with propofol for laryngeal mask insertion

    Directory of Open Access Journals (Sweden)

    A. Sowmya Jayaram

    2014-10-01

    Full Text Available Background: Few studies have assessed adequacy of anaesthesia provided by propofol in combination with dexmedetomidine and propofol in combination with fentanyl for laryngeal mask airway (LMA insertion for minor to moderate elective surgical procedures. Methods: Sixty patients admitted for lower abdominal and lower limb surgery were randomized into Group F (n=30 and Group D (n=30. Thirty seconds  after the study drug (fentanyl1 µg/kg in Group F and dexmedetomidine 1 µg/kg in Group D diluted in 10 mL normal saline over 2 min was administered, induction was done with i.v. propofol 2 mg/kg in both groups. Ninety seconds after propofol injection, jaw relaxation was assessed and LMA of appropriate size was inserted. If the first attempt failed, another attempt was tried after an additional dose of i.v. propofol (0.5 mg/kg. Haemodynamic parameters, namely, heart rate, systolic blood pressure (SBP, mean blood pressure (MBP, diastolic blood pressure (DBP, arterial oxygen saturation measured with pulse oximeter and respiratory rate were recorded before and at the end of 1st, 2nd, 3rd, 5th and 10th minutes after insertion of LMA. Results: Both the groups were comparable in age weight, sex, age wise distribution and insertion conditions. The reductions in SBP, DBP, MAP were greater in Group F (p < 0.001. More patients developed apnoea in Group F than in Group D (p < 0.05. Conclusions: Dexmedetomidine combined with propofol provides the same conditions for LMA insertion as fentanylpropofol combinations with advantage of better maintainance of haemodynamic parameters.

  12. Numerical analysis of modified Central Solenoid insert design

    Energy Technology Data Exchange (ETDEWEB)

    Khodak, Andrei, E-mail: akhodak@pppl.gov [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Martovetsky, Nicolai; Smirnov, Aleksandre [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Titus, Peter [Princeton Plasma Physics Laboratory, Princeton, NJ (United States)

    2015-10-15

    Highlights: • Modified design of coil for testing ITER superconducting cable is presented. • Numerical analysis allowed design verification. • Three-dimensional current sharing temperature distributions are obtained from the results. - Abstract: The United States ITER Project Office (USIPO) is responsible for fabrication of the Central Solenoid (CS) for ITER project. The ITER machine is currently under construction by seven parties in Cadarache, France. The CS Insert (CSI) project should provide a verification of the conductor performance in relevant conditions of temperature, field, currents and mechanical strain. The US IPO designed the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at JAEA, Naka. To validate the modified design three-dimensional numerical simulations were performed using coupled solver for simultaneous structural, thermal and electromagnetic analysis. Thermal and electromagnetic simulations supported structural calculations providing necessary loads and strains. According to current analysis design of the modified coil satisfies ITER magnet structural design criteria for the following conditions: (1) room temperature, no current, (2) temperature 4 K, no current, (3) temperature 4 K, current 60 kA direct charge, and (4) temperature 4 K, current 60 kA reverse charge. Fatigue life assessment analysis is performed for the alternating conditions of: temperature 4 K, no current, and temperature 4 K, current 45 kA direct charge. Results of fatigue analysis show that parts of the coil assembly can be qualified for up to 1 million cycles. Distributions of the Current Sharing Temperature (TCS) in the superconductor were obtained from numerical results using parameterization of the critical surface in the form similar to that proposed for ITER. Special ADPL scripts were developed for ANSYS allowing one-dimensional representation of TCS along the cable, as well as three-dimensional fields of TCS in superconductor

  13. SEQUENCING OF FLAX LIS-1 INSERTION SITE IN THE ALBIDUM GENOTYPE

    Directory of Open Access Journals (Sweden)

    Jana Žiarovská

    2012-12-01

    Full Text Available The paper presents a methodology of identifying the insertion site of LIS-1-1 (Linum Insertion Sequence 1 element in flax Albidum variety when growing under the in vitro combined with environmental stress conditions. Abiotic stress was induced by a reduced nutrient content in a growth medium. The LIS-1 insertion site amplification was reaLIS-1ed using the forward LIS-L: 5'-GGG CAG TTT AAC TGT AAC GAA - 3 'and revers LIS-R: 5'-GCT TGG ATT TAG ACT TGG CAA C - 3' primers by PCR. PCR product was sequenced by direct sequencing method to proove the nucleotide sequence for matching with database LIS-1 sequence. A comparison has been matched with the sequence of the amplified segment in the database for all nucleotides except the 11-position in the 5'-3 ' direction, where instead of the three adenine pair is a couple in the Albidum variety. Changes caused by mobile elements or insertion sequences result in common flax in variability that can be used for the purposes of development of effective marker identification or environment based markers development.

  14. Glycine insertion makes yellow fluorescent protein sensitive to hydrostatic pressure.

    Directory of Open Access Journals (Sweden)

    Tomonobu M Watanabe

    Full Text Available Fluorescent protein-based indicators for intracellular environment conditions such as pH and ion concentrations are commonly used to study the status and dynamics of living cells. Despite being an important factor in many biological processes, the development of an indicator for the physicochemical state of water, such as pressure, viscosity and temperature, however, has been neglected. We here found a novel mutation that dramatically enhances the pressure dependency of the yellow fluorescent protein (YFP by inserting several glycines into it. The crystal structure of the mutant showed that the tyrosine near the chromophore flipped toward the outside of the β-can structure, resulting in the entry of a few water molecules near the chromophore. In response to changes in hydrostatic pressure, a spectrum shift and an intensity change of the fluorescence were observed. By measuring the fluorescence of the YFP mutant, we succeeded in measuring the intracellular pressure change in living cell. This study shows a new strategy of design to engineer fluorescent protein indicators to sense hydrostatic pressure.

  15. Insertion Sequences show diverse recent activities in Cyanobacteria and Archaea

    Directory of Open Access Journals (Sweden)

    Xu Ying

    2008-01-01

    Full Text Available Abstract Background Mobile genetic elements (MGEs play an essential role in genome rearrangement and evolution, and are widely used as an important genetic tool. Results In this article, we present genetic maps of recently active Insertion Sequence (IS elements, the simplest form of MGEs, for all sequenced cyanobacteria and archaea, predicted based on the previously identified ~1,500 IS elements. Our predicted IS maps are consistent with the NCBI annotations of the IS elements. By linking the predicted IS elements to various characteristics of the organisms under study and the organism's living conditions, we found that (a the activities of IS elements heavily depend on the environments where the host organisms live; (b the number of recently active IS elements in a genome tends to increase with the genome size; (c the flanking regions of the recently active IS elements are significantly enriched with genes encoding DNA binding factors, transporters and enzymes; and (d IS movements show no tendency to disrupt operonic structures. Conclusion This is the first genome-scale maps of IS elements with detailed structural information on the sequence level. These genetic maps of recently active IS elements and the several interesting observations would help to improve our understanding of how IS elements proliferate and how they are involved in the evolution of the host genomes.

  16. Toward automated cochlear implant insertion using tubular manipulators

    Science.gov (United States)

    Granna, Josephine; Rau, Thomas S.; Nguyen, Thien-Dang; Lenarz, Thomas; Majdani, Omid; Burgner-Kahrs, Jessica

    2016-03-01

    During manual cochlear implant electrode insertion the surgeon is at risk to damage the intracochlear fine-structure, as the electrode array is inserted through a small opening in the cochlea blindly with little force-feedback. This paper addresses a novel concept for cochlear electrode insertion using tubular manipulators to reduce risks of causing trauma during insertion and to automate the insertion process. We propose a tubular manipulator incorporated into the electrode array composed of an inner wire within a tube, both elastic and helically shaped. It is our vision to use this manipulator to actuate the initially straight electrode array during insertion into the cochlea by actuation of the wire and tube, i.e. translation and slight axial rotation. In this paper, we evaluate the geometry of the human cochlea in 22 patient datasets in order to derive design requirements for the manipulator. We propose an optimization algorithm to automatically determine the tube set parameters (curvature, torsion, diameter, length) for an ideal final position within the cochlea. To prove our concept, we demonstrate that insertion can be realized in a follow-the-leader fashion for 19 out of 22 cochleas. This is possible with only 4 different tube/wire sets.

  17. Design and characterisation of a polyethylene oxide matrix with the potential use as a teat insert for prevention/treatment of bovine mastitis.

    Science.gov (United States)

    Bhattarai, Sushila; Alany, Raid G; Bunt, Craig R; Abdelkader, Hamdy; Rathbone, Michael J

    2015-01-01

    This manuscript reports (for the first time) on antibiotic-free polymeric inserts for the prevention and/or treatment of bovine mastitis. Polyethylene oxide (PEO)-based inserts were prepared using different concentrations of various hydrophilic polymers and water-soluble and water-insoluble drug-release-modifying excipients. A simple and scalable melt-extrusion method was employed to prepare the inserts. The prepared inserts were characterised for their dimension, rheological and mechanical properties. The in vitro release of a model bacteriostatic drug (salicylic acid) from the prepared inserts was studied to demonstrate the effectiveness and reproducibility of the melt-extrusion manufacturing method. Further, the in vitro stability of the inserts was evaluated using gel permeation chromatography (GPC) to monitor any change in molecular weight under real-time and accelerated storage conditions. The investigated inserts were stable at accelerated storage conditions over a period of 6 months. PEO inserts have the potential to serve a dual purpose, act as a physical barrier against pathogens invading the teat canal of cows and possibly control the release of a drug.

  18. Industrial stator vane with sequential impingement cooling inserts

    Science.gov (United States)

    Jones, Russell B; Fedock, John A; Goebel, Gloria E; Krueger, Judson J; Rawlings, Christopher K; Memmen, Robert L

    2013-08-06

    A turbine stator vane for an industrial engine, the vane having two impingement cooling inserts that produce a series of impingement cooling from the pressure side to the suction side of the vane walls. Each insert includes a spar with a row of alternating impingement cooling channels and return air channels extending in a radial direction. Impingement cooling plates cover the two sides of the insert and having rows of impingement cooling holes aligned with the impingement cooling channels and return air openings aligned with the return air channel.

  19. Study on Visually Design of Indexable Insert Tip

    Institute of Scientific and Technical Information of China (English)

    YAO Ji-quan; ZHAO Shu-qiang; ZHANG Shen-hou; CHEN Xin; GUO Xian-yang

    2013-01-01

    In order to improve the development efficiency of the indexable insert tip, three-dimensional parametric and visualization applications program of indexable insert tip was developed in AutoCAD VBA (Visual Basic for Applications). The software could significantly improve the modeling efficiency of indexable insert tip and the model could also be used to static analysis, dynamic analysis and thermodynamic analysis. All aspects of performance could be fully understood by the finite element analysis. The ref-erence for the blade parameters preferred is also provided.

  20. Insertion of short transmembrane helices by the Sec61 translocon.

    Science.gov (United States)

    Jaud, Simon; Fernández-Vidal, Mónica; Nilsson, Ingmarie; Meindl-Beinker, Nadja M; Hübner, Nadja C; Tobias, Douglas J; von Heijne, Gunnar; White, Stephen H

    2009-07-14

    The insertion efficiency of transmembrane (TM) helices by the Sec61 translocon depends on helix amino acid composition, the positions of the amino acids within the helix, and helix length. We have used an in vitro expression system to examine systematically the insertion efficiency of short polyleucine segments (L(n), n = 4 ... 12) flanked at either end by 4-residue sequences of the form XXPX-L(n)-XPXX with X = G, N, D, or K. Except for X = K, insertion efficiency (p) is snorkeling) and by partial unfolding.

  1. Clinical significance of the morphological distribution of the vastus medialis insertion for selection of subvastus approach in total knee arthroplasty

    Institute of Scientific and Technical Information of China (English)

    Huang Baohua; Hou Zhiqi; Chen Yuanming; Qin Jian

    2015-01-01

    Objective To survey and analyze the relationship between the vastus medialis( VM) insertion on the patella and the body projection so as to provide an innovative path to the preoperative evaluation in selecting the subvastus approach in total knee arthroplasty( TKA) . Methods Body-surface projection of the VM patellar insertion was surveyed and the anatomic shape was observed in 20 sides of lower limb specimens. The body-surface projection of the VM patellar insertion was also measured on 80 sides of lower limbs in healthy adults. The distribution results of the VM patellar insertion in the three conditions were compared. Results The ratio of the vastus medialis body length to the patellar length was 40% to 60% in 55. 0% specimens (11 cases). The ratios were (47. 8 ± 15. 1)%, (48. 7 ± 15. 4)% and (46. 7 ± 14. 8)% in the cadaver-surface-observation group, autopsy group and in vivo surface group, respectively. There was no statistical difference (P>0. 05). Conclusions There was no statistical difference in the ratios of the VM patellar insertion length to the patellar length calculated by the observed body-surface-projection values and by the measurements after anatomy. Preoperative evaluation of the body-surface-projection of the VM patellar insertion may play a referential role in the selection of the TKA approach.

  2. The ATRX cDNA is prone to bacterial IS10 element insertions that alter its structure.

    Science.gov (United States)

    Valle-García, David; Griffiths, Lyra M; Dyer, Michael A; Bernstein, Emily; Recillas-Targa, Félix

    2014-01-01

    The SWI/SNF-like chromatin-remodeling protein ATRX has emerged as a key factor in the regulation of α-globin gene expression, incorporation of histone variants into the chromatin template and, more recently, as a frequently mutated gene across a wide spectrum of cancers. Therefore, the availability of a functional ATRX cDNA for expression studies is a valuable tool for the scientific community. We have identified two independent transposon insertions of a bacterial IS10 element into exon 8 of ATRX isoform 2 coding sequence in two different plasmids derived from a single source. We demonstrate that these insertion events are common and there is an insertion hotspot within the ATRX cDNA. Such IS10 insertions produce a truncated form of ATRX, which significantly compromises its nuclear localization. In turn, we describe ways to prevent IS10 insertion during propagation and cloning of ATRX-containing vectors, including optimal growth conditions, bacterial strains, and suggested sequencing strategies. Finally, we have generated an insertion-free plasmid that is available to the community for expression studies of ATRX.

  3. Effect of insertion speed on tissue response and insertion mechanics of a chronically implanted silicon-based neural probe.

    Science.gov (United States)

    Welkenhuysen, M; Andrei, A; Ameye, L; Eberle, W; Nuttin, B

    2011-11-01

    In this study, the effect of insertion speed on long-term tissue response and insertion mechanics was investigated. A dummy silicon parylene-coated probe was used in this context and implanted in the rat brain at 10 μm/s (n = 6) or 100 μm/s (n = 6) to a depth of 9 mm. The insertion mechanics were assessed by the dimpling distance, and the force at the point of penetration, at the end of the insertion phase, and after a 3-min rest period in the brain. After 6 weeks, the tissue response was evaluated by estimating the amount of gliosis, inflammation, and neuronal cell loss with immunohistochemistry. No difference in dimpling, penetration force, or the force after a 3-min rest period in the brain was observed. However, the force at the end of the insertion phase was significantly higher when inserting the probes at 100 μm/s compared to 10 μm/s. Furthermore, an expected tissue response was seen with an increase of glial and microglial reactivity around the probe. This reaction was similar along the entire length of the probe. However, evidence for a neuronal kill zone was observed only in the most superficial part of the implant. In this region, the lesion size was also greatest. Comparison of the tissue response between insertion speeds showed no differences.

  4. The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion.

    Science.gov (United States)

    Deng, Ting; Jiang, Minghui; Lei, Qing; Cai, Lihong; Chen, Li

    2016-12-01

    Clinical trial for cervical screw insertion by using individualized 3-dimensional (3D) printing screw insertion templates device. The objective of this study is to evaluate the safety and accuracy of the individualized 3D printing screw insertion template in the cervical spine. Ten patients who underwent posterior cervical fusion surgery with cervical pedicle screws, laminar screws or lateral mass screws between December 2014 and December 2015 were involved in this study. The patients were examined by CT scan before operation. The individualized 3D printing templates were made with photosensitive resin by a 3D printing system to ensure the screw shafts entered the vertebral body without breaking the pedicle or lamina cortex. The templates were sterilized by a plasma sterilizer and used during the operation. The accuracy and the safety of the templates were evaluated by CT scans at the screw insertion levels after operation. The accuracy of this patient-specific template technique was demonstrated. Only one screw axis greatly deviated from the planned track and breached the cortex of the pedicle because the template was split by rough handling and then we inserted the screws under the fluoroscopy. The remaining screws were inserted in the track as preoperative design and the screw axis deviated by less than 2 mm. Vascular or neurologic complications or injuries did not happen. And no infection, broken nails, fracture of bone structure, or screw pullout occurred. This study verified the safety and the accuracy of the individualized 3D printing screw insertion templates in the cervical spine as a kind of intraoperative screw navigation. This individualized 3D printing screw insertion template was user-friendly, moderate cost, and enabled a radiation-free cervical screw insertion.

  5. A study to investigate needle insertion atShenshu (BL23) to puncture psoas major muscle

    Institute of Scientific and Technical Information of China (English)

    Kwan Leung Chia; Rainer Viktor Haberberger

    2016-01-01

    OBJECTIVE: It is unknown whether the psoas major muscle, thought to be a key muscle for treatment of lower back pain, can be punctured at Shenshu (BL23). METHODS: Twelve dissected specimens were used for studying the needling pathway of BL23 by perpendicularly inserting the depth-measuring blade of a vernier caliper at BL23. Dimensions of psoas muscle were measured. Correlation studies were conducted. In addition, our samples were grouped by gender and underlying medical conditions for analysis. RESULTS:Half (50%) of the needle insertions successfully punctured psoas muscle. The mean depth of needle insertion to puncture psoas muscle (Dmin) in the group with short-term underlying medical conditions was 38.0 mm (interquartile range 29.0–51.8 mm), approximately 6 mm deeper than 32.0 (29.3–42.5) mm in the group with long-term health problems (P = 0.041). The cross-sectional area (CSA) of psoas muscle in the former group was on average approximately 1.5 times that of the latter group (P = 0.04). When the data were analysed by gender, the thickness of psoas muscle in the male group was 19.0 (6.5–24.0) mm compared to 19.5 (5.8–34.8) mm in the female group (P = 0.02). The age in the female group (P = 0.04) and the body length of the total group (P = 0.04) negatively correlated to Dmin. CONCLUSION: Needle insertion at BL23 might be able to puncture psoas muscle. Differences in the CSA of psoas muscle and Dmin were observed in groups with short-term and long-term underlying medical conditions.

  6. The use of dimorphic Alu insertions in human DNA fingerprinting

    Energy Technology Data Exchange (ETDEWEB)

    Novick, G.E.; Gonzalez, T.; Garrison, J.; Novick, C.C.; Herrera, R.J. [Florida International Univ., Miami, FL (United States). Dept. of Biological Sciences; Batzer, M.A. [Lawrence Livermore National Lab., CA (United States); Deininger, P.L. [Louisiana State Univ., New Orleans, LA (United States). Medical Center

    1992-12-04

    We have characterized certain Human Specific Alu Insertions as either dimorphic (TPA25, PV92, APO), sightly dimorphic (C2N4 and C4N4) or monomorphic (C3N1, C4N6, C4N2, C4N5, C4N8), based on studies of Caucasian, Asian, American Black and African Black populations. Our approach is based upon: (1) PCR amplification using primers directed to the sequences that flank the site of insertion of the different Alu elements studied; (2) gel electrophoresis and scoring according to the presence or absence of an Alu insertion in one or both homologous chromosomes; (3) allelic frequencies calculated and compared according to Hardy-Weinberg equilibrium. Our DNA fingerprinting procedure using PCR amplification of dimorphic Human Specific Alu insertions, is stable enough to be used not only as a tool for genetic mapping but also to characterize populations, study migrational patterns and track the inheritance of human genetic disorders.

  7. Membrane protein insertion: mixing eukaryotic and prokaryotic concepts.

    Science.gov (United States)

    Schleiff, Enrico; Soll, Jürgen

    2005-11-01

    Proteins are translocated across or inserted into membranes by machines that are composed of soluble and membrane-anchored subunits. The molecular action of these machines and their evolutionary origin are at present the focus of intense research. For instance, our understanding of the mode of insertion of beta-barrel membrane proteins into the outer membrane of endosymbiotically derived organelles has increased rapidly during the past few years. In particular, the identification of the Omp85/YaeT-involving pathways in Neisseria meningitidis, Escherichia coli and cyanobacteria, and homologues of Omp85/YaeT in chloroplasts and mitochondria, has provided new clues about the ancestral beta-barrel protein insertion pathway. This review focuses on recent advances in the elucidation of the evolutionarily conserved concepts that underlie the translocation and insertion of beta-barrel membrane proteins.

  8. A new insertion sequence for incremental Delaunay triangulation

    Institute of Scientific and Technical Information of China (English)

    Jian-Fei Liu; Jin-Hui Yan; S.H.Lo

    2013-01-01

    Incremental algorithm is one of the most popular procedures for constructing Delaunay triangulations (DTs).However,the point insertion sequence has a great impact on the amount of work needed for the construction of DTs.It affects the time for both point location and structure update,and hence the overall computational time of the triangulation algorithm.In this paper,a simple deterministic insertion sequence is proposed based on the breadth-first-search on a Kd-tree with some minor modifications for better performance.Using parent nodes as search-hints,the proposed insertion sequence proves to be faster and more stable than the Hilbert curve order and biased randomized insertion order (BRIO),especially for non-uniform point distributions over a wide range of benchmark examples.

  9. Aseptic insertion of central venous lines to reduce bacteraemia.

    Science.gov (United States)

    Burrell, Anthony R; McLaws, Mary-Louise; Murgo, Margherita; Calabria, Eda; Pantle, Annette C; Herkes, Robert

    2011-06-06

    To reduce the rate of central line-associated bacteraemia (CLAB). A collaborative quality improvement project in intensive care units (ICUs) to promote aseptic insertion of central venous lines (CVLs). A checklist was used to record compliance with all aspects of aseptic CVL insertion, with maximal sterile barrier precautions for clinicians ("clinician bundle") and patients ("patient bundle"). CLAB was identified and reported using a standard surveillance definition. Patients and clinicians in 37 ICUs in New South Wales, July 2007-December 2008. Compliance with aseptic CVL insertion; rates of CLAB. 10 890 CVL checklists were reviewed for compliance with the clinician and patient bundles: compliance with aseptic CVL insertion improved significantly (P improvement and audit.

  10. Spontaneous Radiation Emission from Short, High Field Strength Insertion Devices

    Energy Technology Data Exchange (ETDEWEB)

    Geoffrey Krafft

    2005-09-15

    Since the earliest papers on undulaters were published, it has been known how to calculate the spontaneous emission spectrum from ''short'' undulaters when the magnetic field strength parameter is small compared to unity, or in ''single'' frequency sinusoidal undulaters where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulater. Fewer general results have been obtained in the case where the insertion device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the insertion device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In this paper a general method is presented for calculating the radiation spectrum for short, high-field insertion devices. It is used to calculate the emission from some insertion device designs of recent interest.

  11. Use of a Nasal Speculum for Chest-Drain Insertion

    Science.gov (United States)

    Saxena, Pankaj; Konstantinov, Igor E.; Newman, Mark A.J.

    2006-01-01

    Tube thoracostomy is a very commonly performed procedure in cardiothoracic surgery. Insertion of a chest drain requires expertise to minimize complications. We describe a simple technique of using a nasal speculum to perform this procedure. PMID:17041709

  12. Optimal trajectory and insertion accuracy of sacral alar iliac screws

    Directory of Open Access Journals (Sweden)

    Katsutaka Yamada

    2017-07-01

    Conclusion: The optimal trajectories of SAISs in a Japanese patient population are more lateral in males and more caudal in females. This study examines the clinical safety and accuracy of SAIS insertion on these optimal trajectories.

  13. Fireplace insert and its parameters depend on the used glazing

    Science.gov (United States)

    Papučík, Štefan; Čaja, Alexander

    2016-06-01

    The contribution deals with the analysis of the impact of using double glass to change the performance and emission parameters of the fireplace insert. Conventional fireplace inserts are equipped with heat-resistant glass, which is resistant to high temperatures. For this type of inserts are required to be radiant constituent maximized. Prevailing part of heat is into the interior gets just by radiation through the glazed part. The hot water fireplace inserts is the requirement that the radiant constituent to the environment to a minimum. Therefore, instead of a single glass using double glazing which is intended to reduce this part of heat transfer. The temperature in the furnace is increased, and transmitted most of the heat into the water.

  14. Modified Seldinger technique for the insertion of standard chest tubes.

    Science.gov (United States)

    Altman, E; Ben-Nun, A; Curtis, W; Best, L A

    2001-04-01

    Closed tube thoracostomy is a standard procedure for the evacuation of air, blood, or other materials from the pleural space. This paper describes a modification of the Seldinger technique that facilitates chest tube insertion. Either a Nelaton or Thieman catheter is threaded into the side drainage hole and out the tip of a standard Argyle-type chest tube. After using the clamp to insert the catheter into the pleural space through a previously dissected tract, the catheter serves as a guide over which the chest tube is inserted. The technique is simple to use, effective, and safe. It employs standard, inexpensive materials to insert chest tubes in such a way as to minimize the potential traumatic complications inherent in other techniques.

  15. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    They reported that friction factor rise due to inclusion of inserts was ... Dasmahapatra and Rao (1991) studied augmentation of heat transfer to viscous non- .... constant throughout the tube length by brazing metal pins to the edges of the tape.

  16. Trajectory generation for robotic needle insertion in soft tissue.

    Science.gov (United States)

    Abolhassani, Niki; Patel, Rajni; Moallem, Mehrdad

    2004-01-01

    Accurate needle insertion in soft, inhomogeneous tissue has been a major concern in several recent studies involving robot-assisted percutaneous therapies. In procedures that involve multiple needle insertions such as transrectal ultrasound guided prostate brachytherapy, it is important to reduce tissue deformation before puncture and during insertion. In order to reduce this deformation, we have studied the effect of different trajectories for a 2-DOF robot performing needle insertion in soft tissue. We have compared tissue deformation and infinitesimal force per tissue displacement for different trajectories. According to the results of our experiments, infinitesimal force per displacement is a useful parameter for online trajectory update. Our proposed position/force controller is shown to provide considerable improvement in performance with regard to tissue deformation before puncture.

  17. Bougie insertion: A common practice with underestimated dangers

    Science.gov (United States)

    Theodorou, D.; Doulami, G.; Larentzakis, A.; Almpanopoulos, K.; Stamou, K.; Zografos, G.; Menenakos, E.

    2011-01-01

    Introduction Esophageal perforation after bariatric operations is rare. We report two cases of esophageal perforation after bariatric operations indicating the dangers of a common practice – like insertion of esophageal tubes – and we describe our management of that complication. Presentation of case A 56 year old woman who underwent laparoscopic sleeve gastrectomy and a 41 year old woman who underwent laparoscopic adjustable gastric banding respectively. In both operations a bougie has been used and led to esophageal perforation. Discussion The insertion of bougie and especially of inflated bougie is a common practice. It is an invasive procedure that in most cases is performed by the anesthesiologist team. Conclusion Bougie insertion is an invasive procedure with risks and should always be attempted under direct supervision of surgical team or should be inserted by a surgeon. PMID:22288051

  18. Lithium Insertion In Silicon Nanowires: An ab Initio Study

    KAUST Repository

    Zhang, Qianfan

    2010-09-08

    The ultrahigh specific lithium ion storage capacity of Si nanowires (SiNWs) has been demonstrated recently and has opened up exciting opportunities for energy storage. However, a systematic theoretical study on lithium insertion in SiNWs remains a challenge, and as a result, understanding of the fundamental interaction and microscopic dynamics during lithium insertion is still lacking. This paper focuses on the study of single Li atom insertion into SiNWs with different sizes and axis orientations by using full ab initio calculations. We show that the binding energy of interstitial Li increases as the SiNW diameter grows. The binding energies at different insertion sites, which can be classified as surface, intermediate, and core sites, are quite different. We find that surface sites are energetically the most favorable insertion positions and that intermediate sites are the most unfavorable insertion positions. Compared with the other growth directions, the [110] SiNWs with different diameters always present the highest binding energies on various insertion locations, which indicates that [110] SiNWs are more favorable by Li doping. Furthermore, we study Li diffusion inside SiNWs. The results show that the Li surface diffusion has a much higher chance to occur than the surface to core diffusion, which is consistent with the experimental observation that the Li insertion in SiNWs is layer by layer from surface to inner region. After overcoming a large barrier crossing surface-to-intermediate region, the diffusion toward center has a higher possibility to occur than the inverse process. © 2010 American Chemical Society.

  19. Equilibrium insertion of nanoscale objects into phospholipid bilayers

    CERN Document Server

    Pogodin, Sergey

    2011-01-01

    Certain membrane proteins, peptides, nanoparticles and nanotubes have rigid structure and fixed shape. They are often viewed as spheres and cylinders with certain surface properties. Single Chain Mean Field theory is used to model the equilibrium insertion of nanoscale spheres and rods into the phospholipid bilayer. The equilibrium structures and the resulting free energies of the nano-objects in the bilayer allow to distinguish different orientations in the bilayer and estimate the energy barrier of insertion.

  20. Hollow polymer microneedles array resistance and insertion tests

    OpenAIRE

    2015-01-01

    Microneedles are developed in order to become the transdermal administration method of the future. They however still face numerous challenges. This paper addresses the challenge to effectively insert the microneedle arrays into membranes. A recently proposed model membrane and test method for microneedles insertion, published in International Journal of Pharmaceutics, is used in this aim. A moulded 4 by 4 hollow polymer microneedle array developed at the Université Libre de Bruxelles is test...

  1. Histological Analysis of the Tibial Anterior Cruciate Ligament Insertion

    OpenAIRE

    Siebold, Rainer; Oka, Shinya; Traut, Ulrike; Schuhmacher, Peter; Kirsch, Joachim

    2017-01-01

    Objective: To describe the morphology of the tibial ACL insertion by histological assessment in the sagittal plane. Methods: For histology the native (undissected) tibial ACL insertion of 6 fresh-frozen cadaveric knees was cut into 4 sagittal sections parallel to the long axis of the medial tibial spine. The slices were stained with hematoxylin and eosin, Safranin O and Russell-Movat pentachrome. All slices were digitalized and analyzed at a magnification of ?20. Results: From medial to later...

  2. Histological analysis of the tibial anterior cruciate ligament insertion.

    Science.gov (United States)

    Oka, Shinya; Schuhmacher, Peter; Brehmer, Axel; Traut, Ulrike; Kirsch, Joachim; Siebold, Rainer

    2016-03-01

    This study was performed to investigate the morphology of the tibial anterior cruciate ligament (ACL) by histological assessment. The native (undissected) tibial ACL insertion of six fresh-frozen cadaveric knees was cut into four sagittal sections parallel to the long axis of the medial tibial spine. For histological evaluation, the slices were stained with haematoxylin and eosin, Safranin O and Russell-Movat pentachrome. All slices were digitalized and analysed at a magnification of 20×. The anterior tibial ACL insertion was bordered by a bony anterior ridge. The most medial ACL fibres inserted from the medial tibial spine and were adjacent to the articular cartilage of the medial tibial plateau. Parts of the bony insertions of the anterior and posterior horns of the lateral meniscus were in close contact with the lateral part of the tibial ACL insertion. A small fat pad was located just posterior to the functional ACL fibres. The anterior-posterior length of the medial ACL insertion was an average of 10.8 ± 1.1 mm compared with the lateral, which was only 6.2 ± 1.1 mm (p flat and 'c-shaped' way. The most anterior part of the tibial ACL insertion was bordered by a bony anterior ridge and the most medial by the medial tibial spine. No posterolateral fibres nor ACL bundles have been found histologically. This histological investigation may improve our understanding of the tibial ACL insertion and may provide important information for anatomical ACL reconstruction.

  3. Blind bedside insertion of small bowel feeding tubes.

    LENUS (Irish Health Repository)

    Duggan, SN

    2009-12-01

    The use of Naso-Jejunal (NJ) feeding is limited by difficulty in feeding tube placement. Patients have traditionally required transfer to Endoscopy or Radiology for insertion of small bowel feeding tubes, with clear resource implications. We hypothesised that the adoption of a simple bedside procedure would be effective and reduce cost. Clinical nutrition and nurse specialist personnel were trained in the 10\\/10\\/10 method of blind bedside NJ insertion.

  4. Modeling Amyloid Beta Peptide Insertion into Lipid Bilayers

    CERN Document Server

    Mobley, D L; Singh, R R P; Maddox, M W; Longo, M J; Mobley, David L.; Cox, Daniel L.; Singh, Rajiv R. P.; Maddox, Michael W.; Longo, Marjorie L.

    2003-01-01

    Inspired by recent suggestions that the Alzheimer's amyloid beta peptide (A-beta), can insert into cell membranes and form harmful ion channels, we model insertion of the peptide into cell membranes using a Monte Carlo code which is specific at the amino acid level. We examine insertion of the regular A-beta peptide as well as mutants causing familial Alzheimer's disease. We present our results and develop the hypothesis that partial insertion into the membrane, leaving the peptide in one leaflet, increases the probability of harmful channel formation. This hypothesis can partly explain why these mutations are neurotoxic simply due to peptide insertion behavior, and also explains why, normally, A-beta 42 is more toxic to some cultured cells than A-beta 40, but the E22Q mutation reverses this effect. We further apply this model to various artificial A-beta mutants which have been examined experimentally, and offer testable experimental predictions contrasting the roles of aggregation and insertion with regard ...

  5. Polyubiquitin insertions and the phylogeny of Cercozoa and Rhizaria.

    Science.gov (United States)

    Bass, David; Moreira, David; López-García, Purificación; Polet, Stephane; Chao, Ema E; von der Heyden, Sophie; Pawlowski, Jan; Cavalier-Smith, Thomas

    2005-08-01

    A single or double amino acid insertion at the monomer-monomer junction of the universal eukaryotic protein polyubiquitin is unique to Cercozoa and Foraminifera, closely related 'core' phyla in the protozoan infrakingdom Rhizaria. We screened 11 other candidate rhizarians for this insertion: Radiozoa (polycystine and acantharean radiolaria), a 'microheliozoan', and Apusozoa; all lack it, supporting suggestions that Foraminifera are more closely related to Cercozoa than either is to other eukaryotes. The insertion's size was ascertained for 12 additional Cercozoa to help resolve their basal branching order. The earliest branching Cercozoa generally have a single amino acid insertion, like all Foraminifera, but a large derived clade consisting of all Monadofilosa except Metopion, Helk-esimastix, and Cercobodo agilis has two amino acids, suggesting one doubling event and no reversions to a single amino acid. Metromonas and Sainouron, cercozoans of uncertain position, have a double insertion, suggesting that they belong in Monadofilosa. An alternative interpretation, suggested by the higher positions for Metopion and Cercobodo on Bayesian trees compared with most distance trees, cannot be ruled out, i.e. that the second insertion took place earlier, in the ancestral filosan, and was followed by three independent reversions to a single amino acid in Chlorarachnea, Metopion and Cercobodo.

  6. Templated sequence insertion polymorphisms in the human genome

    Science.gov (United States)

    Onozawa, Masahiro; Aplan, Peter

    2016-11-01

    Templated Sequence Insertion Polymorphism (TSIP) is a recently described form of polymorphism recognized in the human genome, in which a sequence that is templated from a distant genomic region is inserted into the genome, seemingly at random. TSIPs can be grouped into two classes based on nucleotide sequence features at the insertion junctions; Class 1 TSIPs show features of insertions that are mediated via the LINE-1 ORF2 protein, including 1) target-site duplication (TSD), 2) polyadenylation 10-30 nucleotides downstream of a “cryptic” polyadenylation signal, and 3) preference for insertion at a 5’-TTTT/A-3’ sequence. In contrast, class 2 TSIPs show features consistent with repair of a DNA double-strand break via insertion of a DNA “patch” that is derived from a distant genomic region. Survey of a large number of normal human volunteers demonstrates that most individuals have 25-30 TSIPs, and that these TSIPs track with specific geographic regions. Similar to other forms of human polymorphism, we suspect that these TSIPs may be important for the generation of human diversity and genetic diseases.

  7. Drug transport in HEMA conjunctival inserts containing precipitated drug particles.

    Science.gov (United States)

    Gupta, Chhavi; Chauhan, Anuj

    2010-07-01

    This paper focuses on exploring the mechanism of cyclosporine A transport in hydroxyethyl methacrylate (HEMA) rods to develop conjunctival inserts for extended ocular delivery. Cylindrical conjunctival HEMA inserts were prepared by thermal polymerization in presence of drug at high loadings to create rods containing particles of drug dispersed in the matrix. The drug release rates were measured to explore the effect of length, drug loading, crosslinking, and mixing in the release medium. Also microstructure of the inserts was characterized by SEM imaging. The inserts release the drug for a period of about a month at therapeutic rates. The rates of drug release are zero order and independent of drug loading and crosslinking for certain period of time. These effects were shown to arise due to a mass-transfer boundary layer in the fluid and a mathematical model was developed by coupling mass transfer in the insert with that in the boundary layer in the surrounding fluid. The model with diffusivity in the insert and boundary layer thickness as parameters fits the experimental data and explains all trends in release kinetics. The fitted diffusivity is about twice that obtained by direct measurements, which agreed well with the value obtained by using the Brinkman's equation but only after accounting for drug binding to the polymer.

  8. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  9. Carbon dioxide insertion into diamines: a computational study of solvent effects.

    Science.gov (United States)

    Eger, Wilhelm A; Genest, Alexander; Rieger, Bernhard; Rösch, Notker

    2012-10-01

    We studied computationally, on the model compound ethylenediamine, the insertion of carbon dioxide into diamines, yielding cyclic urea compounds. Two mechanisms were elaborated, depending on the value of the dielectric constant (DC) of the solvent. Accordingly, reaction mixtures with a high DC lead to carbamates, whereas lower DC values result in the preferred product cyclic urea. Additives behaving as "proton shuttles" act as catalysts, significantly reducing the activation barriers of insertion and ring closure to surmountable values. CO(2) insertion into diamines may also occur by autocatalysis, even without further additives, but under less favorable conditions, for example, lower yields. Amine reagents are most efficient at proton shuttling, followed by alcohols. The activation barrier of the rate-limiting step is lowered in a reaction mixture with higher values of DC, up to a critical value ε(cr) ≈ 18. Hence, in a suitably optimized reaction mixture, ring closure is suggested to occur under milder conditions than those previously applied experimentally. The two roles of the additive, that is, acting as proton shuttling agent and adjusting the effective DC of the reaction mixture, do not have to be assigned to a single compound, possibly affording a handle on process optimization.

  10. Gene expression pattern after insertion of dexamethasone-eluting electrode into the guinea pig cochlea.

    Directory of Open Access Journals (Sweden)

    Yutaka Takumi

    Full Text Available A cochlear implant is an indispensable apparatus for a profound hearing loss patient. But insertion of the electrode entails a great deal of stress to the cochlea, and may cause irreversible damage to hair cells and related nerve structure. Although damage prevention effects of dexamethasone have been reported, long-term administration is difficult. In this study, we used a dexamethasone-eluting electrode in the guinea pig cochlea, and compared the gene expression after 7 days insertion with that of a normal electrode and non-surgically treated control by microarray. 40 genes were up-regulated 2-fold or more in the normal electrode group compared to the non-surgically treated group. Most of the up-regulated genes were associated with immune response and inflammation. In the dexamethasone-eluting group, compared to the normal electrode group, 7 of the 40 genes were further up-regulated, while 12 of them were down-regulated and there was a tendency to return to the non-surgical condition. 9 genes were down-regulated 2-fold or less with normal electrode insertion, and 4 of the 9 tended to return to the non-surgical condition in the dexamethasone-eluting group. These genes are certainly involved in the maintenance of the physiological functions of the cochlea. Our results indicate that the dexamethasone-eluting electrode will have an effect on the normalization of homeostasis in the cochlea.

  11. Reactivity Insertion Accident (RIA) Capability Status in the BISON Fuel Performance Code

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, Richard L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Folsom, Charles Pearson [Idaho National Lab. (INL), Idaho Falls, ID (United States); Pastore, Giovanni [Idaho National Lab. (INL), Idaho Falls, ID (United States); Veeraraghavan, Swetha [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-05-01

    One of the Challenge Problems being considered within CASL relates to modelling and simulation of Light Water Reactor LWR) fuel under Reactivity Insertion Accident (RIA) conditions. BISON is the fuel performance code used within CASL for LWR fuel under both normal operating and accident conditions, and thus must be capable of addressing the RIA challenge problem. This report outlines required BISON capabilities for RIAs and describes the current status of the code. Information on recent accident capability enhancements, application of BISON to a RIA benchmark exercise, and plans for validation to RIA behavior are included.

  12. Adequacy of the device intrauterine by ultrasound evaluation: postpartum and post-abortion insertion versus insertion during the menstrual cycle

    National Research Council Canada - National Science Library

    de Holanda, Antônio Arildo Reginaldo; Pessoa, Aline de Melo; Holanda, Julita de Campos Pipolo; de Melo, Maria Helena Vieira; Maranhão, Técia Maria de Oliveira

    2013-01-01

    To compare by transvaginal ultrasound the position of the intrauterine device (IUD) inside the uterine cavity, depending on the time of insertion, postpartum and post-abortion, and during the menstrual cycle...

  13. Comparison study of the pullout strength of conventional spinal pedicle screws and a novel design in full and backed-out insertions using mechanical tests.

    Science.gov (United States)

    Amaritsakul, Yongyut; Chao, Ching-Kong; Lin, Jinn

    2014-03-01

    Recently, new pedicle screw designs have been developed. However, these designs' performances are still unclear, especially when backed out after insertion. The objective of this study was to investigate the performances of different screw designs when backed out from full insertion. Seven conventional designs of the pedicle screw and one novel design were inserted into polyurethane foam (0.32 g/cm(3)). All screws were first fully inserted (43 mm) and were backed out 360°. Axial pullout tests were performed and the reaction force was measured. The results showed that the conical screw of type 1 with a small inner diameter provided the highest pullout strength in both full insertion and backed-out insertion (2401.85 and 2169.82 N, respectively). However, this screw's pullout strength significantly decreased (9.7%) when backed out from full insertion. There was no significant difference between the conical screw of type 1 with a small inner diameter and double duo core screw (p > 0.01) in backed-out insertion. The cylindrical screw with a small diameter, dual inner core screw and double dual core screw also provided good results in both full insertion (2115.44, 2182.99 and 2226.93 N, respectively) and backed-out conditions (2065.80, 2014.28 and 1941.29 N, respectively). The increased pullout strength of the conical design could be due to the effect of bone compaction. However, the screw exhibited less consistent pullout strength when backed out when compared with the other designs. The conical screw should be inserted to the precise position without turning back, especially in osteoporosis patients. The dual inner core screw and double dual core screw could provide greater stability in both conditions. Care should be taken when using both the cylindrical screw with a small thread depth and the dual outer core screw.

  14. Does hard insertion and space improve shock absorption ability of mouthguard?

    Science.gov (United States)

    Takeda, Tomotaka; Ishigami, Keiichi; Handa, Jun; Naitoh, Kaoru; Kurokawa, Katsuhide; Shibusawa, Mami; Nakajima, Kazunori; Kawamura, Shintaro

    2006-04-01

    Mouthguards are expected to reduce sports-related orofacial injuries. Numerous studies have been conduced to improve the shock absorption ability of mouthguards using air cells, sorbothane, metal wire, or hard material insertion. Most of these were shown to be effective; however, the result of each study has not been applied to clinical use. The aim of this study was to develop mouthguards that have sufficient prevention ability and ease of clinical application with focus on a hard insertion and space. Ethylene vinyl acetate (EVA) mouthguard blank used was Drufosoft and the acrylic resin was Biolon (Dreve-Dentamid GMBH, Unna, Germany). Three types of mouthguard samples tested were constructed by means of a Dreve Drufomat (Type SO, Dreve-Dentamid) air pressure machine: the first was a conventional laminated type of EVA mouthguard material; the second was a three layer type with acrylic resin inner layer (hard-insertion); the third was the same as the second but with space that does not come into contact with tooth surfaces (hard + space). As a control, without any mouthguard condition (NOMG) was measured. A pendulum type impact testing machine with interchangeable impact object (steel ball and baseball) and dental study model (D17FE-NC.7PS, Nissin, Tokyo, Japan) with the strain gages (KFG-1-120-D171-11N30C2: Kyowa, Tokyo, Japan) applied to teeth and the accelerometer to the dentition (AS-A YG-2768 100G, Kyowa) were used to measure transmitted forces. Statistical analysis (anova, P shock absorption ability of about 40% was shown with conventional EVA and hard-insertion and about 50% with hard + space. In a baseball that was softer compared with steel ball, a decrease rate is smaller, reduction (EVA = approximately 4%, hard-insertion = approximately 12%, hard + space = approximately 25%) was admitted in the similar order. A significant difference was found with all the combinations except for between EVA and hard-insertion with steel ball (Tukey test). About

  15. Effects on behaviour and rein tension on horses ridden with or without martingales and rein inserts.

    Science.gov (United States)

    Heleski, C R; McGreevy, P D; Kaiser, L J; Lavagnino, M; Tans, E; Bello, N; Clayton, H M

    2009-07-01

    Unsteady hand position can cause discomfort to the horse, potentially leading to conflict behaviours (CB) such as head tossing or tail lashing. Some instructors feel that martingales or elastic rein inserts can reduce discomfort caused by inexperienced and unsteady hands. Others consider these devices to be inappropriate 'crutches'. Four horses and nine riders were tested under three conditions in random order: plain reins, adjustable training martingales (TM), and elasticised rein inserts (RI). Rein-tension data (7s) and behavioural data (30s) were collected in each direction. Rein-tension data were collected via strain-gauge transducers. Behavioural data were assessed using an ethogram of defined behaviours. No differences in the number of CB were observed. Mean rein tension for TM was higher than that of RI or controls. Relative to the withers, the head was lower for horses ridden with martingales. Carefully fitted martingales may have a place in riding schools that teach novices.

  16. Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector

    Directory of Open Access Journals (Sweden)

    Jafar M. Hassan

    2015-09-01

    Full Text Available In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5. The collectors are connected in parallel mode (Z-Configuration and are exposed to the same conditions (solar radiation and ambient temperature .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3 .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at different flow rate used (60,100 and 150 ℓ /hr. were 49 %, 57% and 63% respectively.

  17. Controlling Posture and Vergence Eye Movements in Quiet Stance: Effects of Thin Plantar Inserts.

    Directory of Open Access Journals (Sweden)

    A Foisy

    Full Text Available The purpose of this study was to assess properties of vergence and saccade eye movements as well as posture in quiet stance, and the effects of thin plantar inserts upon postural and oculomotor control. The performances of 36 young healthy subjects were recorded by a force platform and an eye tracker in three testing conditions: without plantar stimulation, with a 3 millimetre-thick plantar insert, either a Medial or a Lateral Arch Support (MAS/LAS. The results showed a decrease of the Surface and Variance of Speed and a more posterior position of the CoP with either stimulation compared with the control condition. The fractal analysis showed a decrease with MAS. Wavelet analysis in the time-frequency domain revealed an increase in the Cancelling Time of the low frequency band with MAS. These results suggest a better stability for a lower energy cost. Concerning eye movements, the inserts influenced only vergence (not saccades: MAS caused an increase of the phasic amplitude of divergence, and conversely a decrease of the tonic amplitude. In contrast, LAS caused an increase of the tonic amplitude of convergence. Thus, MAS renders divergence less visually driven, while LAS renders convergence more visually driven. We conclude that the CNS uses the podal signal for both postural and vergence control via specific mechanisms. Plantar inserts have an influence upon posture and vergence movements in a different way according to the part of the foot sole being stimulated. These results can be useful to clinicians interested in foot or eye.

  18. Manufacture of the poloidal field conductor insert coil (PFCI)

    Energy Technology Data Exchange (ETDEWEB)

    Baker, W. [EFDA CSU Garching, Boltzmannstrasse 2, 85748 Garching bei Muenchen (Germany); Keefe, C. [Tesla Engineering, Storrington, Sussex (United Kingdom); Rajainmaeki, H. [EFDA CSU Garching, Boltzmannstrasse 2, 85748 Garching bei Muenchen (Germany)], E-mail: hannu.rajainmaki@tech.efda.org; Salpietro, E. [EFDA CSU Garching, Boltzmannstrasse 2, 85748 Garching bei Muenchen (Germany)

    2007-10-15

    Within the framework of the R and D programme for international thermonuclear experimental reactor (ITER) the European team European Fusion Development Agreement (EFDA) has been charged with the design and manufacture of the poloidal field conductor insert coil (PFCI). The purpose of the PFCI is to test and demonstrate the performance of long-length full-scale NbTi conductors in ITER-relevant conditions. The PFCI will be tested in the central solenoid model coil test facility at the JAEA, Naka, Japan. This paper details the complete manufacturing of the PFCI including development, forming machining, pre-assembly, impregnation, final assembly and testing. The PFCI is a single-layered wound solenoid of nine turns with a transition joggle in the centre section of the winding and an intermediate joint connection between the upper termination and the main coil winding. To give the required overall dimensions to fit in the testing facility, preformed and machined glass resin composite filler pieces are assembled with the winding and is finally vacuum pressure impregnated (VPI) to create a single assembly unit. The PFCI is enclosed for assembly in a support structure, which consists of an upper and lower flange, each made up of four electrically insulated machined stainless steel castings, and 12 tie rods preloading the complete assembly in the vertical direction. The upper flange is equipped with four radial restraining jacks and the lower flange is equipped with four sets of studs and shear keys to withstand the net vertical and lateral electromagnetic forces. The PFCI is equipped with inductive heaters, voltage taps, temperature transducers, strain gauges and other instrumentation as diagnostics to monitor the performance. The current status of the manufacture is that the coil has passed the final acceptance tests and it is in the support structure assembly stage.

  19. Urethral catheter insertion forces: a comparison of experience and training

    Directory of Open Access Journals (Sweden)

    Benjamin K. Canales

    2009-02-01

    Full Text Available Purpose: This study was undertaken to evaluate the insertion forces utilized during simulated placement of a urethral catheter by healthcare individuals with a variety of catheter experience. Materials and Methods: A 21F urethral catheter was mounted to a metal spring. Participants were asked to press the tubing spring against a force gauge and stop when they met a level of resistance that would typically make them terminate a catheter placement. Simulated catheter insertion was repeated fives times, and peak compression forces were recorded. Healthcare professionals were divided into six groups according to their title: urology staff, non-urology staff, urology resident/ fellow, non-urology resident/ fellow, medical student, and registered nurse. Results: A total of fifty-seven healthcare professionals participated in the study. Urology staff (n = 6 had the lowest average insertion force for any group at 6.8 ± 2.0 Newtons (N. Medical students (n = 10 had the least amount of experience (1 ± 0 years and the highest average insertion force range of 10.1 ± 3.7 N. Health care workers with greater than 25 years experience used significantly less force during catheter insertions (4.9 ± 1.8 N compared to all groups (p < 0.01. Conclusions: We propose the maximum force that should be utilized during urethral catheter insertion is 5 Newtons. This force deserves validation in a larger population and should be considered when designing urethral catheters or creating catheter simulators. Understanding urethral catheter insertion forces may also aid in establishing competency parameters for health care professionals in training.

  20. Development of the needle insertion robot for percutaneous vertebroplasty.

    Science.gov (United States)

    Onogi, S; Morimoto, K; Sakuma, I; Nakajima, Y; Koyama, T; Sugano, N; Tamura, Y; Yonenobu, S; Momoi, Y

    2005-01-01

    Percutaneous Vertebroplasty (PVP) is an effective and less invasive medical treatment for vertebral osteoporotic compression fractures. However, this operative procedure is quite difficult because an arcus vertebra, which is narrow, is needled with accuracy, and an operator's hand is exposed to X-ray continuously. We have developed a needle insertion robot for Percutaneous Vertebroplasty. Its experimental evaluation on the basic performance of the system and needle insertion accuracy are presented. A needle insertion robot is developed for PVP. This robot can puncture with accuracy and an operator does not need to be exposed to X-ray. The mechanism of the robot is compact in size (350 mm x D 400 mm x H270 mm, weight: 15 kg) so that the robot system can be inserted in the space between C-arm and the patient on the operating table. The robot system is controlled by the surgical navigation system where the appropriate needle trajectory is planned based on pre-operative three-dimensional CT images. The needle holding part of the robot is X-ray lucent so that the needle insertion process can be monitored by fluoroscopy. The position of the needle during insertion process can be continuously monitored. In vitro evaluation of the system showed that average position and orientation errors were less than 1.0 mm and 1.0 degree respectively. Experimental results showed that the safety mechanism called mechanical fuse released the needle holding disk properly when excessive force was applied to the needle. These experimental results demonstrated that the developed system has the satisfactory basic performance as needle insertion robot for PVP.

  1. Preprocedural ultrasound examination versus manual palpation for thoracic epidural catheter insertion

    Directory of Open Access Journals (Sweden)

    Ahmed M Hasanin

    2017-01-01

    Conclusion: Preprocedural ultrasound imaging increased the incidence of first pass success in thoracic epidural catheter insertion and reduced the catheter insertion time compared to manual palpation method.

  2. Patterns of transposable element expression and insertion in cancer

    Directory of Open Access Journals (Sweden)

    Evan A Clayton

    2016-11-01

    Full Text Available Human transposable element (TE activity in somatic tissues causes mutations that can contribute to tumorigenesis. Indeed, TE insertion mutations have been implicated in the etiology of a number of different cancer types. Nevertheless, the full extent of somatic TE activity, along with its relationship to tumorigenesis, have yet to be fully explored. Recent developments in bioinformatics software make it possible to analyze TE expression levels and TE insertional activity directly from transcriptome (RNA-seq and whole genome (DNA-seq next-generation sequence data. We applied these new sequence analysis techniques to matched normal and primary tumor patient samples from the Cancer Genome Atlas (TCGA in order to analyze the patterns of TE expression and insertion for three cancer types: breast invasive carcinoma, head and neck squamous cell carcinoma, and lung adenocarcinoma. Our analysis focused on the three most abundant families of active human TEs: Alu, SVA and L1. We found evidence for high levels of somatic TE activity for these three families in normal and cancer samples across diverse tissue types. Abundant transcripts for all three TE families were detected in both normal and cancer tissues along with an average of ~80 unique TE insertions per individual patient/tissue. We observed an increase in L1 transcript expression and L1 insertional activity in primary tumor samples for all three cancer types. Tumor-specific TE insertions are enriched for private mutations, consistent with a potentially causal role in tumorigenesis. We used genome feature analysis to investigate two specific cases of putative cancer-causing TE mutations in further detail. An Alu insertion in an upstream enhancer of the CBL tumor suppressor gene is associated with down-regulation of the gene in a single breast cancer patient, and an L1 insertion in the first exon of the BAALC gene also disrupts its expression in head and neck squamous cell carcinoma. Our results are

  3. Transposable element insertions have strongly affected human evolution.

    Science.gov (United States)

    Britten, Roy J

    2010-11-16

    Comparison of a full collection of the transposable element (TE) sequences of vertebrates with genome sequences shows that the human genome makes 655 perfect full-length matches. The cause is that the human genome contains many active TEs that have caused TE inserts in relatively recent times. These TE inserts in the human genome are several types of young Alus (AluYa5, AluYb8, AluYc1, etc.). Work in many laboratories has shown that such inserts have many effects including changes in gene expression, increases in recombination, and unequal crossover. The time of these very effective changes in the human lineage genome extends back about 4 million years according to these data and very likely much earlier. Rapid human lineage-specific evolution, including brain size is known to have also occurred in the last few million years. Alu insertions likely underlie rapid human lineage evolution. They are known to have many effects. Examples are listed in which TE sequences have influenced human-specific genes. The proposed model is that the many TE insertions created many potentially effective changes and those selected were responsible for a part of the striking human lineage evolution. The combination of the results of these events that were selected during human lineage evolution was apparently effective in producing a successful and rapidly evolving species.

  4. Some physical and chemical indices of clique-inserted lattices

    Science.gov (United States)

    Zhang, Zuhe

    2013-10-01

    The operation of replacing every vertex of an r-regular lattice H by a complete graph of order r is called clique-insertion, and the resulting lattice is called the clique-inserted lattice of H. For any given r-regular lattice, applying this operation iteratively, an infinite family of r-regular lattices is generated. Some interesting lattices including the 3-12-12 lattice can be constructed this way. In this paper, we recall the relationship between the spectra of an r-regular lattice and that of its clique-inserted lattice, and investigate the graph energy and resistance distance statistics. As an application, the asymptotic energy per vertex and average resistance distance of the 3-12-12 and 3-6-24 lattices are computed. We also give formulae expressing the numbers of spanning trees and dimer coverings of the kth iterated clique-inserted lattices in terms of those of the original one. Moreover, we show that new families of expander graphs can be constructed from the known ones by clique-insertion.

  5. Recombination of an intrachromosomal paracentric insertion of chromosome 3

    Energy Technology Data Exchange (ETDEWEB)

    Best, R.G.; Burnett, W.J.; Brock, J.K. [Univ. of South Carolina School of Medicine, Columbia, SC (United States)] [and others

    1994-09-01

    Cytogenetic studies were initiated on a newborn female due to multiple congenital anomalies including microcephaly, clinodactyly, abnormal positioning of hands, left facial palsy, heart defect, sacral dimple, and facial dysmorphic features. Facial features were described as low set rotated ears, nystagmus, and a small, flattened nose. A structural rearrangement of the long arm of chromosome 3 was observed with a complex banding pattern. Study of parental chromosomes revealed a normal male pattern for the father, and an intrachromosomal insertion on the long arm of chromosome 3 for the mother described as 46,XX,dir ins(3)(q21q23q26.2). Further characterization of the proband`s structurally abnormal chromosome 3 revealed a karyotype best described as: 46,XX,rec(3),dupq23{r_arrow}q26.2::q21{r_arrow}q23,dir ins(3)(q21q23q26.2), which is a partial duplication of both the inserted segment as well as the intervening segment between the inserted segment and the insertion site. This would appear to be the result of a three-strand double cross-over within the insertion loop. Molecular cytogenetic studies are presently underway to further elucidate chromosome structure of the proband and her mother.

  6. Seamless lesion insertion in digital mammography: methodology and reader study

    Science.gov (United States)

    Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman

    2016-03-01

    Collection of large repositories of clinical images containing verified cancer locations is costly and time consuming due to difficulties associated with both the accumulation of data and establishment of the ground truth. This problem poses a significant challenge to the development of machine learning algorithms that require large amounts of data to properly train and avoid overfitting. In this paper we expand the methods in our previous publications by making several modifications that significantly increase the speed of our insertion algorithms, thereby allowing them to be used for inserting lesions that are much larger in size. These algorithms have been incorporated into an image composition tool that we have made publicly available. This tool allows users to modify or supplement existing datasets by seamlessly inserting a real breast mass or micro-calcification cluster extracted from a source digital mammogram into a different location on another mammogram. We demonstrate examples of the performance of this tool on clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM). Finally, we report the results of a reader study evaluating the realism of inserted lesions compared to clinical lesions. Analysis of the radiologist scores in the study using receiver operating characteristic (ROC) methodology indicates that inserted lesions cannot be reliably distinguished from clinical lesions.

  7. Customizable engineered blood vessels using 3D printed inserts.

    Science.gov (United States)

    Pinnock, Cameron B; Meier, Elizabeth M; Joshi, Neeraj N; Wu, Bin; Lam, Mai T

    2016-04-15

    Current techniques for tissue engineering blood vessels are not customizable for vascular size variation and vessel wall thickness. These critical parameters vary widely between the different arteries in the human body, and the ability to engineer vessels of varying sizes could increase capabilities for disease modeling and treatment options. We present an innovative method for producing customizable, tissue engineered, self-organizing vascular constructs by replicating a major structural component of blood vessels - the smooth muscle layer, or tunica media. We utilize a unique system combining 3D printed plate inserts to control construct size and shape, and cell sheets supported by a temporary fibrin hydrogel to encourage cellular self-organization into a tubular form resembling a natural artery. To form the vascular construct, 3D printed inserts are adhered to tissue culture plates, fibrin hydrogel is deposited around the inserts, and human aortic smooth muscle cells are then seeded atop the fibrin hydrogel. The gel, aided by the innate contractile properties of the smooth muscle cells, aggregates towards the center post insert, creating a tissue ring of smooth muscle cells. These rings are then stacked into the final tubular construct. Our methodology is robust, easily repeatable and allows for customization of cellular composition, vessel wall thickness, and length of the vessel construct merely by varying the size of the 3D printed inserts. This platform has potential for facilitating more accurate modeling of vascular pathology, serving as a drug discovery tool, or for vessel repair in disease treatment.

  8. LMA Supreme insertion by novices in manikins and patients.

    Science.gov (United States)

    Howes, B W; Wharton, N M; Gibbison, B; Cook, T M

    2010-04-01

    The LMA Supreme has been suggested for use in emergency situations by medical personnel with no experience in endotracheal intubation. We evaluated the LMA Supreme when inserted by non-anaesthetists, firstly in a manikin and then in patients. Fifty airway novices inserted a LMA Supreme in a manikin without any complications so we proceeded to the patient phase. Fifty airway novices inserted the LMA Supreme in anaesthetised patients undergoing elective surgery. First time insertion success rate was 86% and overall insertion success rate was 100%. Mechanical ventilation was successful in all cases. Median (IQR [range]) time to establish an airway was 34 s (26-40 [18-145] s). Median (IQR [range]) pharyngeal seal pressure was 23 cmH(2)O (19-28 [13-40] cmH(2)O). There were no important complications. Results are consistent with previous studies of use of the LMA Supreme by airway experts. We conclude that the LMA supreme is suitable for use by airway novices. Further research is needed before it may be recommended for cardiopulmonary resuscitation and emergency airway use.

  9. Measurement of trocar insertion force using a piezoelectric transducer.

    Science.gov (United States)

    Ng, Pui Shan; Sahota, Daljit Singh; Yuen, Pong Mo

    2003-11-01

    We attempted to establish a model to measure the force required for trocar insertion at laparoscopy. A 3-cm, circular transducer was constructed from piezoresistive material that changes its impedance as force is exerted on its surface. The transducer is connected by an interface box to a personal computer to record surface contact pressure digitally (pressure = force/area) profile continuously during trocar insertion. Each subject had three trocars inserted: a 10-mm trocar at the umbilicus after creation of pneumoperitoneum, and 5-mm trocars at corresponding sites on the left and right sides of the lower abdomen. All insertions were performed by the same operator using reusable trocar with a conical tip. Each subject acted as her own control. Recordings were successfully obtained from eight women. There was no instance of transducer failure. The mean (SE) peak contact surface pressure for the 10-mm and 5-mm left and right trocars were 5.3 (0.32), 6.4 (0.51), and 6.81 (0.27) pounds/square inch, respectively. Placement of the 10-mm trocar required less insertion force than placement of the 5-mm trocars. There was a strong negative correlation (r = -0.97, p trocar.

  10. Heat Transfer Enhancement by Using Different Types of Inserts

    Directory of Open Access Journals (Sweden)

    S. Tabatabaeikia

    2014-07-01

    Full Text Available Heat transfer enhancement has been always a significantly interesting topic in order to develop high efficient, low cost, light weight, and small heat exchangers. The energy cost and environmental issue are also encouraging researchers to achieve better performance than the existing designs. Two of the most effective ways to achieve higher heat transfer rate in heat exchangers are using different kinds of inserts and modifying the heat exchanger tubes. There are different kinds of inserts employed in the heat exchanger tubes such as helical/twisted tapes, coiled wires, ribs/fins/baffles, and winglets. This paper presents an overview about the early studies on the improvement of the performance of thermal systems by using different kinds of inserts. Louvered strip insert had better function in backward flow compared to forward one. Modifying the shape of twisted tapes led to a higher efficiency in most of the cases excpet for perforated twisted tape and notched twisted tape. Combination of various inserts and tube with artificial roughness provided promising results. In case of using various propeller types, heat transfer enhancement was dependent on higher number of blades and blade angle and lower pitch ratio.

  11. Optimized production and concentration of lentiviral vectors containing large inserts.

    Science.gov (United States)

    al Yacoub, Nadya; Romanowska, Malgorzata; Haritonova, Natalie; Foerster, John

    2007-07-01

    Generation of high titer lentiviral stocks and efficient virus concentration are central to maximize the utility of lentiviral technology. Here we evaluate published protocols for lentivirus production on a range of transfer vectors differing in size (7.5-13.2 kb). We present a modified virus production protocol robustly yielding useful titers (up to 10(7)/ml) for a range of different transfer vectors containing packaging inserts up to 7.5 kb. Moreover, we find that virus recovery after concentration by ultracentrifugation depends on the size of the packaged inserts, heavily decreasing for large packaged inserts. We describe a fast (4 h) centrifugation protocol at reduced speed allowing high virus recovery even for large and fragile lentivirus vectors. The protocols outlined in the current report should be useful for many labs interested in producing and concentrating high titer lentiviral stocks.

  12. Reliable communication over non-binary insertion/deletion channels

    CERN Document Server

    Yazdani, Raman

    2012-01-01

    We consider the problem of reliable communication over non-binary insertion/deletion channels where symbols are randomly deleted from or inserted in the transmitted sequence and all symbols are corrupted by additive white Gaussian noise. To this end, we utilize the inherent redundancy achievable in non-binary symbol sets by first expanding the symbol set and then allocating part of the bits associated with each symbol to watermark symbols. The watermark sequence, known at the receiver, is then used by a forward-backward algorithm to provide soft information for an outer code which decodes the transmitted sequence. Through numerical results and discussions, we evaluate the performance of the proposed solution and show that it leads to significant system ability to detect and correct insertions/deletions. We also provide estimates of the maximum achievable information rates of the system, compare them with the available bounds, and construct practical codes capable of approaching these limits.

  13. The strategic use of inserts in the Brazilian presidential elections

    Directory of Open Access Journals (Sweden)

    Felipe Borba

    2012-01-01

    Full Text Available The aim of this article is to analyze the communication strategies of presidential candidates during the elections held in 2006 and 2010. The focus is on the strategic component of electoral inserts and the methodology consists of investigating how candidates choose to distribute these inserts in the programming of television networks. The results indicate that the candidates pursue different strategies influenced basically by three variables: electoral legislation, their standing in polls and the difference of resources available. In parallel, the article debates the role of the regulation of electoral advertising and how this set of rules influences the level of information of campaigns, the occurrence of attacks, and party strategies. Overall, 2,993 electoral inserts were examined.

  14. ADDITIONAL TENDINOUS INSERTION OF BICEPS BRACHII: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Daimi S.R

    2010-03-01

    Full Text Available In view of the variable presentations of biceps brachii, a proper understanding of the anatomy of the muscle, and possible anatomical variants is a pre-requisite in managing distal biceps injury. We present the case of a 65 years old male cadaver showing variationin the insertion pattern of biceps brachii muscle unilaterally on the left arm. Although the origin of the muscle was normal, its insertion was by two separate tendons; a common and an accessory; both inserting on diverse regions of the radial tuberosity. The common tendon was formed by the tendons from short head and long head. The accessory tendon was the extension of the fleshy belly on the lateral side of the main muscle (Accessory Muscle Belly towards its lower third. Knowledge of the accessory tendon of the biceps iscrucial while performing tendon reconstruction and repair and it may also lead to unusual displacement of the bone fragment, subsequent to fracture.

  15. Polyglutamine expansion in huntingtin increases its insertion into lipid bilayers.

    Science.gov (United States)

    Kegel, Kimberly B; Schewkunow, Vitali; Sapp, Ellen; Masso, Nicholas; Wanker, Erich E; DiFiglia, Marian; Goldmann, Wolfgang H

    2009-09-25

    An expanded polyglutamine (Q) tract (>37Q) in huntingtin (htt) causes Huntington disease. Htt associates with membranes and polyglutamine expansion in htt may alter membrane function in Huntington disease through a mechanism that is not known. Here we used differential scanning calorimetry to examine the effects of polyQ expansion in htt on its insertion into lipid bilayers. We prepared synthetic lipid vesicles composed of phosphatidylcholine and phosphatidylethanolamine and tested interactions of htt amino acids 1-89 with 20Q, 32Q or 53Q with the vesicles. GST-htt1-89 with 53Q inserted into synthetic lipid vesicles significantly more than GST-htt1-89 with 20Q or 32Q. We speculate that by inserting more into cell membranes, mutant huntingtin could increase disorder within the lipid bilayer and thereby disturb cellular membrane function.

  16. Genetic aspects of targeted insertion mutagenesis in yeasts.

    Science.gov (United States)

    Klinner, U; Schäfer, B

    2004-05-01

    Targeted insertion mutagenesis is a main molecular tool of yeast science initially applied in Saccharomyces cerevisiae. The method was extended to fission yeast Schizosaccharomyces pombe and to "non-conventional" yeast species, which show specific properties of special interest to both basic and applied research. Consequently, the behaviour of such non-Saccharomyces yeasts is reviewed against the background of the knowledge of targeted insertion mutagenesis in S. cerevisiae. Data of homologous integration efficiencies obtained with circular, ends-in or ends-out vectors in several yeasts are compared. We follow details of targeted insertion mutagenesis in order to recognize possible rate-limiting steps. The route of the vector to the target and possible mechanisms of its integration into chromosomal genes are considered. Specific features of some yeast species are discussed. In addition, similar approaches based on homologous recombination that have been established for the mitochondrial genome of S. cerevisiae are described.

  17. Isolation of sequences flanking Ac insertion sites by Ac casting.

    Science.gov (United States)

    Wang, Dafang; Peterson, Thomas

    2013-01-01

    Localizing Ac insertions is a fundamental task in studying Ac-induced mutation and chromosomal rearrangements involving Ac elements. Researchers may sometimes be faced with the situation in which the sequence flanking one side of an Ac/Ds element is known, but the other flank is unknown. Or, a researcher may have a small sequence surrounding the Ac/Ds insertion site and needs to obtain additional flanking genomic sequences. One way to rapidly clone unknown Ac/Ds flanking sequences is via a PCR-based method termed Ac casting. This approach utilizes the somatic transposition activity of Ac during plant development, and provides an efficient means for short-range genome walking. Here we describe the principle of Ac casting, and show how it can be applied to isolate Ac macrotransposon insertion sites.

  18. Experimental Study on Heat Transfer Characteristics of Shell and Tube Heat Exchanger Using Hitran Wire Matrix Turbulators As Tube Inserts.

    Directory of Open Access Journals (Sweden)

    Manoj

    2014-06-01

    Full Text Available Shell and tube heat exchangers are extensively used in boilers, oil coolers, pre-heaters, condensers etc. They are also having special importance in process application as well as refrigeration and air conditioning industries. The present paper emphasizes on heat transfer characteristics of shell and tube heat exchangers with the aid of hiTRAN wire matrix inserts is been studied. Investigations were made on effect of mass flow rate of water on heat transfer characteristics in case of plain tube without inserts. When hiTRAN wire matrix tube inserts are used, which effectively increases the turbulence of tube side flow due to the hydrodynamic and thermal agitation of boundary layer in turns increases additional pressure drop is available in the system. This results in increase in the wall shear, reduced wall temperature which enhances substantial increase in tube side heat transfer characteristics. Heat and cooling processes streams is a standard operation in many industries this operation is often performed in heat exchangers where the heated or cold fluid flows under laminar conditions inside the tubes the mechanisms of under those flow conditions are complex poorly understood since they can involve both forced and natural convection making accurate prediction for heat exchanger. Heat transfer in laminar flow regimes is low by default but can be greatly increased by the use of passive heat transfer enhancement such as tube inserts. The present analysis the hiTRAN wire matrix turbulators were used and increased heat transfer characteristics as expected outcomes.

  19. INSERTING STIPULATION PERTAINING TO POLYGAMY IN A MARRIAGE CONTRACT IN MUSLIM COUNTRIES

    Directory of Open Access Journals (Sweden)

    Raihanah Abdullah

    2008-02-01

    Full Text Available Generally, Islam permits a wife to stipulate any conditions in a marriage contract. The Muslim jurists however differed in determining the validity of certain conditions and terms upon which their marriage is to take place. One of the controversial conditions is that the wife includes a condition pertaining to polygamy in the marriage contract. It is interesting to note that the practice of inserting stipulations pertaining to polygamy is not a new practice or unusual among many Muslims in the Middle East. Therefore, this article seeks to discuss the possibilities to adopt the Hanbalite’s principles on this matter in muslim countries where the Shafi’ite school of thought is predominantly followed. This article argued that by allowing the wife to insert stipulations pertaining to polygamy in a marriage contract does not go against Islam. This is because stipulations in the marriage contract are often aimed at preventing such eventuality and also protecting the position of women should it come to prevent.

  20. Bedside prediction of right subclavian venous catheter insertion length

    Directory of Open Access Journals (Sweden)

    Yoon Ji Choi

    2014-12-01

    Full Text Available Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC, via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively. Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89. The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm = -0.037 + 0.036 × Height (cm + 0.903 × I-T-IC (cm (adjusted r2 =0.64. Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation.

  1. Effect of Light Conducting Cylindrical Inserts on Gingival Microleakage

    Directory of Open Access Journals (Sweden)

    SM. Moazzami

    2007-03-01

    Full Text Available Objective: Microleakage in the gingival floor of class II composite restorations can compromise the marginal adaptation of the filling material to the cavity edges. The aim of this study was to evaluate the effect of light conducting cylindrical inserts in decreasing the microleakage of the gingival floor in cavities 1mm below the CEJ.Materials and Methods: Eighty maxillary first molars were randomly divided into eight groups according to use of glass inserts, type of resin (Coltene unfilled resin versus Scotchbond multi purpose and filling technique (one-unit versus incremental. Proximal class II cavities were prepared in all samples with the gingival floor one millimeter below the CEJ. Etched and silan-treated glass inserts were made from 2mm cylindrical bioglass material and cavities were restored according to research protocol. The samples were subjected to 2500 thermal cycles (5-55oC, immersed in 0.5% basic fuchsin solution, embedded in epoxy resin and cut centrally and laterally (buccally or lingually in a mesiodistal direction. Microleakage was scored and collected data were statistically analyzed using Kruskal-Wallis and Mann-Whitney tests.Results: Minimal dye penetration was observed in the group that employed the incre-mental technique along with Scotchbond, with or without glass inserts. A significant difference was observed between the eight groups. In addition the use of the incremental technique and glass inserts had a significant effect on the microleakage of lateral and central sections, respectively. Application of dentin bonding agent signifi-cantly affected both sections.Conclusion: Glass inserts were effective in decreasing cervical microleakage of class II cavities restored with composite resin.

  2. Comparison of sevoflurane concentration for insertion of proseal laryngeal mask airway and tracheal intubation in children (correlation with BIS).

    Science.gov (United States)

    Mudakanagoudar, Mahantesh S; Santhosh, M C B

    2016-01-01

    Sevoflurane is an inhalational agent of choice in paediatric anaesthesia. For management of airways in children a suitable alternative to ETT is a paediatric proseal laryngeal mask airway (benchmark second generation SAD). Various studies have shown that less sevoflurane concentration is required for LMA insertion in comparison to TI. BIS is a useful monitor of depth of anaesthesia. To compare concentration of sevoflurane (end tidal and MAC value) required for proseal laryngeal mask airway insertion and tracheal intubation in correlation with BIS index. The prospective randomised single blind study was done in children between 2 and 9 years of ASA I and II and they were randomly allocated to Group P (proseal laryngeal mask airway insertion) and Group TI (tracheal intubation). No sedative premedication was given. Induction was done with 8% sevoflurane and then predetermined concentration was maintained for 10 min. Airway was secured either by proseal laryngeal mask airway or endotracheal tube without using muscle relaxant. End tidal sevoflurane concentration, MAC, BIS, and other vital parameters were monitored every minute till insertion of an airway device. Insertion conditions were observed. Statistical analysis was done by ANOVA and Students t test. Difference between ETLMI (2.49 ± 0.44) and ETTI (2.81 ± 0.65) as well as MACLMI (1.67 ± 0.13) and MACTI (1.77 ± 0.43) was statistically very significant, while BISLMI (49.05 ± 10.76) and BISTI (41.25 ± 3.25) was significant. Insertion conditions were comparable in both the groups. We can conclude that in children airway can be secured safely with proseal laryngeal mask airway using less sevoflurane concentration in comparison to tracheal intubation and this was supported by BIS index. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  3. [Comparison of sevoflurane concentration for insertion of proseal laryngeal mask airway and tracheal intubation in children (correlation with BIS)].

    Science.gov (United States)

    Mudakanagoudar, Mahantesh S; Santhosh, M C B

    2016-01-01

    Sevoflurane is an inhalational agent of choice in paediatric anaesthesia. For management of airways in children a suitable alternative to ETT is a paediatric proseal laryngeal mask airway (benchmark second generation SAD). Various studies have shown that less sevoflurane concentration is required for LMA insertion in comparison to TI. BIS is a useful monitor of depth of anaesthesia. To compare concentration of sevoflurane (end tidal and MAC value) required for proseal laryngeal mask airway insertion and tracheal intubation in correlation with BIS index. The prospective randomised single blind study was done in children between 2 and 9 years of ASA I and II and they were randomly allocated to Group P (proseal laryngeal mask airway insertion) and Group TI (tracheal intubation). No sedative premedication was given. Induction was done with 8% sevoflurane and then predetermined concentration was maintained for 10min. Airway was secured either by proseal laryngeal mask airway or endotracheal tube without using muscle relaxant. End tidal sevoflurane concentration, MAC, BIS, and other vital parameters were monitored every minute till insertion of an airway device. Insertion conditions were observed. Statistical analysis was done by Anova and Student's t test. Difference between ETLMI (2.49±0.44) and ETTI (2.81±0.65) as well as MACLMI (1.67±0.13) and MACTI (1.77±0.43) was statistically very significant, while BISLMI (49.05±10.76) and BISTI (41.25±3.25) was significant. Insertion conditions were comparable in both the groups. We can conclude that in children airway can be secured safely with proseal laryngeal mask airway using less sevoflurane concentration in comparison to tracheal intubation and this was supported by BIS index. Copyright © 2014. Publicado por Elsevier Editora Ltda.

  4. Comparison of sevoflurane concentration for insertion of proseal laryngeal mask airway and tracheal intubation in children (correlation with BIS

    Directory of Open Access Journals (Sweden)

    Mahantesh S. Mudakanagoudar

    2016-02-01

    Full Text Available BACKGROUND: Sevoflurane is an inhalational agent of choice in paediatric anaesthesia. For management of airways in children a suitable alternative to ETT is a paediatric proseal laryngeal mask airway (benchmark second generation SAD. Various studies have shown that less sevoflurane concentration is required for LMA insertion in comparison to TI. BIS is a useful monitor of depth of anaesthesia. AIMS: To compare concentration of sevoflurane (end tidal and MAC value required for proseal laryngeal mask airway insertion and tracheal intubation in correlation with BIS index. METHOD: The prospective randomised single blind study was done in children between 2 and 9 years of ASA I and II and they were randomly allocated to Group P (proseal laryngeal mask airway insertion and Group TI (tracheal intubation. No sedative premedication was given. Induction was done with 8% sevoflurane and then predetermined concentration was maintained for 10 min. Airway was secured either by proseal laryngeal mask airway or endotracheal tube without using muscle relaxant. End tidal sevoflurane concentration, MAC, BIS, and other vital parameters were monitored every minute till insertion of an airway device. Insertion conditions were observed. Statistical analysis was done by ANOVA and Students t test. RESULTS: Difference between ETLMI (2.49 ± 0.44 and ETTI (2.81 ± 0.65 as well as MACLMI (1.67 ± 0.13 and MACTI (1.77 ± 0.43 was statistically very significant, while BISLMI (49.05 ± 10.76 and BISTI (41.25 ± 3.25 was significant. Insertion conditions were comparable in both the groups. CONCLUSION: We can conclude that in children airway can be secured safely with proseal laryngeal mask airway using less sevoflurane concentration in comparison to tracheal intubation and this was supported by BIS index.

  5. Forward and reverse genetics: The LORE1 retrotransposon insertion mutants

    DEFF Research Database (Denmark)

    Fukai, Eigo; Malolepszy, Anna; Sandal, Niels Nørgaard

    2014-01-01

    The endogenous Lotus retrotransposon 1 (LORE1) transposes in the germ line of Lotus japonicus plants that carry an active element. This feature of LORE1 has been exploited for generation of a large non-transgenic insertion mutant population, where insertions have been annotated using next......-generation sequencing approaches. The LORE1 mutant lines are freely available and can be ordered online. Endogenous retrotransposons are also active in many other plant species. Based on the methods developed for LORE1 mutagenesis, it should be simple to establish similar systems in other species, once an appropriate...

  6. Tension Pneumothorax and Subcutaneous Emphysema Complicating Insertion of Nasogastric Tube

    Directory of Open Access Journals (Sweden)

    Narjis AL Saif

    2015-01-01

    Full Text Available Nasogastric tube has a key role in the management of substantial number of hospitalized patients particularly the critically ill. In spite of the apparent simple insertion technique, nasogastric tube placement has its serious perhaps fatal complications which need to be carefully assessed. Pulmonary misplacement and associated complications are commonplace during nasogastric tube procedure. We present a case of tension pneumothorax and massive surgical emphysema in critically ill ventilated patient due to inadvertent nasogastric tube insertion and also discussed the risk factors, complication list, and arrays of techniques for safer tube placement.

  7. Technology Insertion and Management: Options for the Canadian Forces

    Science.gov (United States)

    2010-01-01

    L’insertion technologique et la gestion de la technologie : Options pour les Forces canadiennes », est une analyse documentaire qualitative de niveau...l’insertion technologique et son utilisation parmi les alliés du Canada et fournira certaines méthodes qui sont nécessaires pour faire une analyse ...technologique. Enfin, elle a fourni une gamme de méthodes nécessaires à une analyse coûts-avantages fondée sur l’optimisation des options en matière

  8. Ultrasonic airborne insertion loss measurements at normal incidence (L).

    Science.gov (United States)

    Farley, Jayrin; Anderson, Brian E

    2010-12-01

    Transmission loss and insertion loss measurements of building materials at audible frequencies are commonly made using plane wave tubes or as a panel between reverberant rooms. These measurements provide information for noise isolation control in architectural acoustics and in product development. Airborne ultrasonic sound transmission through common building materials has not been fully explored. Technologies and products that utilize ultrasonic frequencies are becoming increasingly more common, hence the need to conduct such measurements. This letter presents preliminary measurements of the ultrasonic insertion loss levels for common building materials over a frequency range of 28-90 kHz using continuous-wave excitation.

  9. Insertion of lithium into electrochromic devices after completion

    Energy Technology Data Exchange (ETDEWEB)

    Berland, Brian Spencer; Lanning, Bruce Roy; Frey, Jonathan Mack; Barrett, Kathryn Suzanne; DuPont, Paul Damon; Schaller, Ronald William

    2015-12-22

    The present disclosure describes methods of inserting lithium into an electrochromic device after completion. In the disclosed methods, an ideal amount of lithium can be added post-fabrication to maximize or tailor the free lithium ion density of a layer or the coloration range of a device. Embodiments are directed towards a method to insert lithium into the main device layers of an electrochromic device as a post-processing step after the device has been manufactured. In an embodiment, the methods described are designed to maximize the coloration range while compensating for blind charge loss.

  10. Insertion of lithium into electrochromic devices after completion

    Energy Technology Data Exchange (ETDEWEB)

    Berland, Brian Spencer; Lanning, Bruce Roy; Frey, Jonathan Mack; Barrett, Kathryn Suzanne; DuPont, Paul Damon; Schaller, Ronald William

    2015-12-22

    The present disclosure describes methods of inserting lithium into an electrochromic device after completion. In the disclosed methods, an ideal amount of lithium can be added post-fabrication to maximize or tailor the free lithium ion density of a layer or the coloration range of a device. Embodiments are directed towards a method to insert lithium into the main device layers of an electrochromic device as a post-processing step after the device has been manufactured. In an embodiment, the methods described are designed to maximize the coloration range while compensating for blind charge loss.

  11. Tension Pneumothorax and Subcutaneous Emphysema Complicating Insertion of Nasogastric Tube.

    Science.gov (United States)

    Al Saif, Narjis; Hammodi, Adel; Al-Azem, M Ali; Al-Hubail, Rasheed

    2015-01-01

    Nasogastric tube has a key role in the management of substantial number of hospitalized patients particularly the critically ill. In spite of the apparent simple insertion technique, nasogastric tube placement has its serious perhaps fatal complications which need to be carefully assessed. Pulmonary misplacement and associated complications are commonplace during nasogastric tube procedure. We present a case of tension pneumothorax and massive surgical emphysema in critically ill ventilated patient due to inadvertent nasogastric tube insertion and also discussed the risk factors, complication list, and arrays of techniques for safer tube placement.

  12. Fabrication of Functional Plastic Parts Using Nanostructured Steel Mold Inserts

    Directory of Open Access Journals (Sweden)

    Nicolas Blondiaux

    2017-06-01

    Full Text Available We report on the fabrication of sub-micro and nanostructured steel mold inserts for the replication of nanostructured immunoassay biochips. Planar and microstructured stainless steel inserts were textured at the sub-micron and nanoscale by combining nanosphere lithography and electrochemical etching. This allowed the fabrication of structures with lateral dimensions of hundreds of nanometers and aspect ratios of up to 1:2. Nanostructured plastic parts were produced by means of hot embossing and injection molding. Surface nanostructuring was used to control wettability and increase the sensitivity of an immunoassay.

  13. Design and resistive inserts for NHMFL 45-T hybrid magnet

    Energy Technology Data Exchange (ETDEWEB)

    Bird, M.D.; Bole, S.; Eyssa, Y.M.; Gao, B.J.; Zhang, H.; Schneider-Muntau, H.J. [National High Magnetic Field Lab., Tallahassee, FL (United States)

    1994-07-01

    The authors present conceptual designs for 24--27 MW hybrid magnet inserts generating more than 31 T in a warm bore of 32 mm to be installed at the new National High Magnetic Field Laboratory (NHMFL). The insert housing is designed to accommodate both axially and radially cooled magnets although here they only present axially cooled designs. The magnet coils are radially partitioned (poly-Bitter) to provide high fields at moderate stress and cooling levels. GlidCop, Cu-Be and Cu-Ag conductors are considered providing resistive fields at high as 34 T in a background field of 14 T.

  14. Imaging of the complications of peripherally inserted central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Amerasekera, S.S.H. [Department of Radiology, Good Hope Hospital, Sutton Coldfield, Birmingham (United Kingdom)], E-mail: steve.amerasekera@nhs.net; Jones, C.M.; Patel, R.; Cleasby, M.J. [Department of Radiology, Good Hope Hospital, Sutton Coldfield, Birmingham (United Kingdom)

    2009-08-15

    Peripherally inserted central catheters (PICC) are widely used to provide central venous access, often in chronically ill patients with long-term intravenous access requirements. There are a number of significant complications related to both insertion and maintenance of PICC lines, including catheter malposition, migration, venous thrombosis, and line fracture. The incidence of these complications is likely to rise as the number of patients undergoing intravenous outpatient therapy increases, with a corresponding rise in radiologist input. This paper provides an overview of the relevant peripheral and central venous anatomy, including anatomical variations, and outlines the complications of PICC lines. Imaging examples demonstrate the range of radiological findings seen in these complications.

  15. Imaging of the complications of peripherally inserted central venous catheters.

    Science.gov (United States)

    Amerasekera, S S H; Jones, C M; Patel, R; Cleasby, M J

    2009-08-01

    Peripherally inserted central catheters (PICC) are widely used to provide central venous access, often in chronically ill patients with long-term intravenous access requirements. There are a number of significant complications related to both insertion and maintenance of PICC lines, including catheter malposition, migration, venous thrombosis, and line fracture. The incidence of these complications is likely to rise as the number of patients undergoing intravenous outpatient therapy increases, with a corresponding rise in radiologist input. This paper provides an overview of the relevant peripheral and central venous anatomy, including anatomical variations, and outlines the complications of PICC lines. Imaging examples demonstrate the range of radiological findings seen in these complications.

  16. Direct Synthesis of Telechelic Polyethylene by Selective Insertion Polymerization

    KAUST Repository

    Jian, Zhongbao

    2016-10-14

    A single-step route to telechelic polyethylene (PE) is enabled by selective insertion polymerization. PdII-catalyzed copolymerization of ethylene and 2-vinylfuran (VF) generates α,ω-di-furan telechelic polyethylene. Orthogonally reactive exclusively in-chain anhydride groups are formed by terpolymerization with carbic anhydride. Combined experimental and theoretical DFT studies reveal the key for this direct approach to telechelics to be a match of the comonomers’ different electronics and bulk. Identified essential features of the comonomer are that it is an electron-rich olefin that forms an insertion product stabilized by an additional interaction, namely a π–η3 interaction for the case of VF.

  17. Can femoral dialysis catheter insertion cause a life threatening complication?

    Directory of Open Access Journals (Sweden)

    Nurkay Katrancıoğlu

    2014-09-01

    Full Text Available Venous catheter (VC insertion may be necessary for the patients with renal failure facing vascular access problem. Femoral VCs are commonly used for their lower complication rates especially in emergency clinics. The incidence of bleeding associated with VC is reported 0.5-1.6%, however, life threatening hemorrhage and complications requiring surgical intervention are very rare. In this manuscript, we aimed to present a case with hemolytic uremic syndrome complicated with retroperitoneal hematoma after femoral VC insertion. J Clin Exp Invest 2014; 5 (3: 472-474

  18. Removable partial dentures with rotational paths of insertion: problem analysis.

    Science.gov (United States)

    Firtell, D N; Jacobson, T E

    1983-07-01

    Removable partial dentures designed to use a rotational path of insertion are technique sensitive. When indicated and when the principles discussed are followed, a denture that uses a rotational path can be highly successful. Tooth coverage can be decreased, which is an advantage in plaque control, caries reduction, and periodontal support. Esthetics can be improved without resorting to intracoronal retainers, and the number of components subject to distortion is reduced. When properly designed and constructed, use of a rotational path of insertion can result in a removable partial denture that is strong, hygienic, and esthetic.

  19. Shield Insertion to Minimize Noise Amplitude in Global Interconnects

    Directory of Open Access Journals (Sweden)

    Kalpana.A.B

    2012-09-01

    Full Text Available Shield insertion is an effective technique for minimise crosstalk noise and signal delay uncertainty .To reduce the effects of coupling uniform or simultaneous shielding may be used on either or both sides of a signal line. Shields are ground or power lines placed between two signal wires to prevent direct coupling between them as the shield width increases, the noise amplitude decreases, in this paper inserting a shield line between two coupled interconnects is shown to be more effective in reducing crosstalk noise for different technology nodes .

  20. Definition of Metrics to Evaluate Cochlear Array Insertion Forces Performed with Forceps, Insertion Tool, or Motorized Tool in Temporal Bone Specimens

    Directory of Open Access Journals (Sweden)

    Yann Nguyen

    2014-01-01

    Full Text Available Introduction. In order to achieve a minimal trauma to the inner ear structures during array insertion, it would be suitable to control insertion forces. The aim of this work was to compare the insertion forces of an array insertion into anatomical specimens with three different insertion techniques: with forceps, with a commercial tool, and with a motorized tool. Materials and Methods. Temporal bones have been mounted on a 6-axis force sensor to record insertion forces. Each temporal bone has been inserted, with a lateral wall electrode array, in random order, with each of the 3 techniques. Results. Forceps manual and commercial tool insertions generated multiple jerks during whole length insertion related to fits and starts. On the contrary, insertion force with the motorized tool only rose at the end of the insertion. Overall force momentum was 1.16 ± 0.505 N (mean ± SD, n=10, 1.337 ± 0.408 N (n=8, and 1.573 ± 0.764 N (n=8 for manual insertion with forceps and commercial and motorized tools, respectively. Conclusion. Considering force momentum, no difference between the three techniques was observed. Nevertheless, a more predictable force profile could be observed with the motorized tool with a smoother rise of insertion forces.

  1. Microwave-assisted chemical insertion: a rapid technique for screening cathodes for Mg-ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Kaveevivitchai, Watchareeya; Huq, Ashfia; Manthiram, Arumugam

    2016-12-19

    We report an ultrafast microwave-assisted solvothermal method for chemical insertion of Mg2+ ions into host materials using magnesium acetate [Mg(CH3COO)2] as a metal-ion source and diethylene glycol (DEG) as a reducing agent. For instance, up to 3 Mg ions per formula unit of a microporous host framework Mo2.5+yVO9+z could be inserted in as little as 30 min at 170–195 °C in air. This process is superior to the traditional method which involves the use of organometallic reagents, such as di-n-butylmagnesium [(C4H9)2Mg] and magnesium bis(2,6-di-tert-butylphenoxide) [Mg-(O-2,6-But2C6H3)2], and requires an inert atmosphere with extremely long reaction times. Considering the lack of robust electrolytes for Mg-ion batteries, this facile approach can be readily used as a rapid screening technique to identify potential Mg-ion electrode hosts without the necessity of fabricating electrodes and assembling electrochemical cells. Due to the mild reaction conditions, the overall structure and morphology of the Mg-ion inserted products are maintained and the compounds can be used successfully as a cathode in Mg-ion batteries. The combined synchrotron X-ray and neutron diffraction Rietveld analysis reveals the structure of the Mg-inserted compounds and gives an insight into the interactions between the Mg ions and the open-tunnel host framework.

  2. The supermodule insertion tool of the CMS electromagnetic calorimeter and the first trial insertion of a supermodule.

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The first trial insertion of a complete Electromagnetic Calorimeter (ECAL) "supermodule" (1700 lead-tungstate crystals, with support structures, light detectors (avalanche photodiodes), readout electronics and cooling system) was performed on 1st March. This delicate operation - sliding a 2-tonne 3m-long object onto support rails (in real life these are attached to the barrel hadron calorimeter (HCAL)) - made use of a custom designed "squirrel cage". The rotatable squirrel cage allows the insertion of any supermodule into any of the 18 positions, including very fine (sub-mm) adjustments. The first supermodule will be inserted into the real HCAL later this month in preparation for the "magnet test and cosmic-ray challenge" (MTCC). In the first image the supermodule is in the centre and the alignment disks are highlighted by the flash.

  3. [Adequacy of the device intrauterine by ultrasound evaluation: postpartum and post-abortion insertion versus insertion during the menstrual cycle].

    Science.gov (United States)

    de Holanda, Antônio Arildo Reginaldo; Pessoa, Aline de Melo; Holanda, Julita de Campos Pipolo; de Melo, Maria Helena Vieira; Maranhão, Técia Maria de Oliveira

    2013-08-01

    To compare by transvaginal ultrasound the position of the intrauterine device (IUD) inside the uterine cavity, depending on the time of insertion, postpartum and post-abortion, and during the menstrual cycle. Epidemiologic, observational and cross-sectional study carried out between February and July, 2013. A total of 290 women were included, 205 of them with insertion during the menstrual cycle and 85 during the postpartum and post-abortion periods. The independent variables were: age, parity, time of use, insertion time, number of returns to family planning, satisfaction with the method, wish to continue using the device, symptoms and complications. The dependent variable was the adequate position of the IUD inside the uterine cavity. The χ² test with Pearson's correction and the Fisher exact test were used for statistical analysis, with the level of significance set at 5%. The average age was 29.4 years and the average time of IUD use was 2.7 years; 39.3% of the women had symptoms associated with the method, the most frequent being menorrhagia (44.7%). The degree of satisfaction was 85% and 61.4% of the women returned two or more times for consultation about family planning. Age, parity and the position of the uterus in the pelvic cavity was not associated with a poor position of the IUD inside the uterine cavity (p>0.05). Insertion during the menstrual cycle was significantly more associated with a correct position of the IUD than postpartum and post-abortion insertion (pabortion insertion showed worse results regarding the adequacy of IUD position, a fact that was not observed regarding age, parity or position of the uterus in the pelvic cavity.

  4. How does the Shift-insertion sort behave when the sorting elements follow a Normal distribution?

    CERN Document Server

    Pal, Mita; Mahanti, N C

    2012-01-01

    The present paper examines the behavior of Shift-insertion sort (insertion sort with shifting) for normal distribution inputs and is in continuation of our earlier work on this new algorithm for discrete distribution inputs, namely, negative binomial. Shift insertion sort is found more sensitive for main effects but not for all interaction effects compared to conventional insertion sort.

  5. Automatic needle insertion diminishes pain during growth hormone injection

    DEFF Research Database (Denmark)

    Main, K M; Jørgensen, J T; Hertel, N T

    1995-01-01

    prototype pens for GH administration, providing either manual or automatic sc needle insertion, using a combined visual analogue/facial scale and a five-item scale in 18 children. With the automatic pen there was a significantly lower maximum pain score compared with the manual pen (median 28.5 versus 52...

  6. Meningococcal septic shock after IUD insertion, a case presentation.

    Science.gov (United States)

    Romosan, Gina; Blidisel, A; Grigoras, D; Houtsios, A; Ionac, M

    2013-01-01

    Neisseria meningitidis is a normal commensal of human mucous membranes that is no longer considered to be restricted to the nasopharynx. Due to the practice of oral sex, the mucous membranes of the cervix, urethra or anus have become a potential infection site for this bacterium. Inserting an intrauterine device (IUD), can alter the protective barrier of the endocervical mucosa, allowing for bacterial infection and systemic spread. We present a case report of a 40-year-old woman who presented with abdominal pain, spotting and fever after inserting an IUD and developed a fulminant septic shock. Blood cultures and cultures from ascites showed the presence of Neisseria meningitidis group Y. From our knowledge, there are a few cases presented in the literature of toxic shock syndrome after IUD insertion, caused by Staphylococcus aureus or Streptococcus group A, but this is the first case of meningococcal sepsis after IUD insertion described. So, even though IUDs rarely cause significant infection, physicians should consider this device as a possible source in reproductive-age women with the clinical features of sepsis.

  7. ArcGIS Tool: Inserts file name into attribute table

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This ArcGIS model inserts a file name into a feature class attribute table. The tool allows an user to identify features by a field that reference the name of the...

  8. Folding and insertion thermodynamics of the transmembrane WALP peptide

    Energy Technology Data Exchange (ETDEWEB)

    Bereau, Tristan, E-mail: bereau@mpip-mainz.mpg.de [Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz (Germany); Bennett, W. F. Drew [Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1 (Canada); Pfaendtner, Jim [Department of Chemical Engineering, University of Washington, Seattle, Washington 98195 (United States); Deserno, Markus [Department of Physics, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Karttunen, Mikko [Department of Mathematics and Computer Science & Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, MetaForum, 5600 MB Eindhoven (Netherlands)

    2015-12-28

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA){sub n} (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide’s insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum—in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence.

  9. Observations on rotating needle insertions using a brachytherapy robot

    Energy Technology Data Exchange (ETDEWEB)

    Meltsner, M A [Department of Medical Physics, University of Wisconsin, Madison, WI 53706 (United States); Ferrier, N J [Department of Mechanical Engineering, University of Wisconsin, Madison, WI 53706 (United States); Thomadsen, B R [Department of Medical Physics, University of Wisconsin, Madison, WI 53706 (United States)

    2007-09-21

    A robot designed for prostate brachytherapy implantations has the potential to greatly improve treatment success. Much of the research in robotic surgery focuses on measuring accuracy. However, there exist many factors that must be optimized before an analysis of needle placement accuracy can be determined. Some of these parameters include choice of the needle type, insertion velocity, usefulness of the rotating needle and rotation speed. These parameters may affect the force at which the needle interacts with the tissue. A reduction in force has been shown to decrease the compression of the prostate and potentially increase the accuracy of seed position. Rotating the needle as it is inserted may reduce frictional forces while increasing accuracy. However, needle rotations are considered to increase tissue damage due to the drilling nature of the insertion. We explore many of the factors involved in optimizing a brachytherapy robot, and the potential effects each parameter may have on the procedure. We also investigate the interaction of rotating needles in gel and suggest the rotate-cannula-only method of conical needle insertion to minimize any tissue damage while still maintaining the benefits of reduced force and increased accuracy.

  10. Proper Angle of Sono-guided Central Venous Line Insertion

    Science.gov (United States)

    Barzegari, Hassan; Forouzan, Arash; Fahimi, Mohammad Ali; Zohrevandi, Behzad; Ghanavati, Mandana

    2016-01-01

    Introduction: Determining the proper angle for inserting central venous catheter (CV line) is of great importance for decreasing the complications and increasing success rate. The present study was designed to determine the proper angle of needle insertion for internal jugular vein catheterization. Methods: In the present case series study, candidate patients for catheterization of the right internal jugular vein under guidance of ultrasonography were studied. At the time of proper placing of the catheter, photograph was taken and Auto Cad 2014 software was used to measure the angles of the needle in the sagittal and axial planes, as well as patient’s head rotation. Result: 114 patients with the mean age of 56.96 ± 14.71 years were evaluated (68.4% male). The most common indications of catheterization were hemodialysis (55.3%) and shock state (24.6%). The mean angles of needle insertion were 102.15 ± 6.80 for axial plane, 36.21 ± 3.12 for sagittal plane and the mean head rotation angle was 40.49 ± 5.09. Conclusion: Based on the results of the present study it seems that CV line insertion under the angles 102.15 ± 6.80 degrees in the axial plane, 36.21 ± 3.12 in the sagittal plane and 40.49 ± 5.09 head rotation yield satisfactory results. PMID:27299146

  11. Astronaut Scott Carpenter inserted into Aurora 7 spacecraft

    Science.gov (United States)

    1962-01-01

    Astronaut M. Scott Carpenter, pilot of the Mercury-Atlas 7 space flight, is inserted into Aurora 7 spacecraft during the prelaunch countdown. Carpenter is assisted into the spacecraft by Astronaut John Glenn and Gunter Vendt, McDonnell Douglas pad capsule test conducter.

  12. INSULATING CERAMIC INSERTS FOR CASTING PRODUCTS FROM ALUMINUM ALLOYS

    OpenAIRE

    2015-01-01

    The paper analyses production of reusable ceramic insulating inserts applied in permanent mold casting of aluminum alloys. It presents results of manufacturing of ceramic products from synthesized materials based on wollastonite, secondary grog, aluminum slag, etc. The paper demonstrates prospects of their applying.

  13. INSULATING CERAMIC INSERTS FOR CASTING PRODUCTS FROM ALUMINUM ALLOYS

    Directory of Open Access Journals (Sweden)

    A. T. Volochko

    2015-01-01

    Full Text Available The paper analyses production of reusable ceramic insulating inserts applied in permanent mold casting of aluminum alloys. It presents results of manufacturing of ceramic products from synthesized materials based on wollastonite, secondary grog, aluminum slag, etc. The paper demonstrates prospects of their applying.

  14. Contrast-free endoscopic stent insertion in malignant biliary obstruction

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    AIM: To present a case series of MRCP-guided endoscopic biliary stent placement, performed entirely without contrast injection.METHODS: Contrast-free endoscopic biliary drainage was attempted in 20 patients with malignant obstruction,unsuitable for resection on the basis of tumor extent or medical illness. MRCP images were used to confirm the diagnosis of tumor, to exclude other biliary diseases and to demonstrate the stenoses as well as dilation of proximal liver segments. The procedure was carried out under conscious sedation. Patients were placed in the left lateral decubitus position. The endoscope was inserted, the papilla identified and cannulated by a papillotome. A guide wire was inserted and guided deeply into the biliary tree, above the stenosis, by fluoroscopy. A papillotomy approximately 1 cm. long was performed and the papillotome was exchanged with a guiding-catheter. A 10 Fr, Amsterdam-type plastic stent,7 to 15 cm long, was finally inserted over the guide wire/guiding catheter by a pusher tube system.RESULTS: Successful stent insertion was achieved in all patients. There were no major complications. Successful drainage, with substantial reduction in bilirubin levels,was achieved in all patients.CONCLUSION: This new method of contrast-free endoscopic stenting in malignant biliary obstruction is a safe and effective method of palliation. However, a larger, randomized study comparing this new approach with the standard procedure is needed to confirm the findings of the present study.

  15. Prototype ISR Superconducting Quadrupole for the low beta insertion.

    CERN Multimedia

    1976-01-01

    The four coils are provisionally kept together by aluminium clamps while epoxy-glass bands are wrapped around them to form a number of spacer rings.Stainless steel spacers were then inserted between these rings and the yoke quadrants. The persons are Michel Bouvier(left) and Pierre Pugin. See also7702690X.

  16. Eustachian tube function in children after insertion of ventilation tubes.

    NARCIS (Netherlands)

    Heerbeek, N. van; Ingels, K.J.A.O.; Snik, A.F.M.; Zielhuis, G.A.

    2001-01-01

    This study was performed to assess the effect of the insertion of ventilation tubes and the subsequent aeration of the middle ear on eustachian tube (ET) function in children. Manometric ET function tests were performed repeatedly for 3 months after the placement of ventilation tubes in 83 children

  17. Insertion DNA Accelerates Meiotic Interchromosomal Recombination in Arabidopsis thaliana.

    Science.gov (United States)

    Sun, Xiao-Qin; Li, Ding-Hong; Xue, Jia-Yu; Yang, Si-Hai; Zhang, Yan-Mei; Li, Mi-Mi; Hang, Yue-Yu

    2016-08-01

    Nucleotide insertions/deletions are ubiquitous in eukaryotic genomes, and the resulting hemizygous (unpaired) DNA has significant, heritable effects on adjacent DNA. However, little is known about the genetic behavior of insertion DNA. Here, we describe a binary transgenic system to study the behavior of insertion DNA during meiosis. Transgenic Arabidopsis lines were generated to carry two different defective reporter genes on nonhomologous chromosomes, designated as "recipient" and "donor" lines. Double hemizygous plants (harboring unpaired DNA) were produced by crossing between the recipient and the donor, and double homozygous lines (harboring paired DNA) via self-pollination. The transfer of the donor's unmutated sequence to the recipient generated a functional β-glucuronidase gene, which could be visualized by histochemical staining and corroborated by polymerase chain reaction amplification and sequencing. More than 673 million seedlings were screened, and the results showed that meiotic ectopic recombination in the hemizygous lines occurred at a frequency  >6.49-fold higher than that in the homozygous lines. Gene conversion might have been exclusively or predominantly responsible for the gene correction events. The direct measurement of ectopic recombination events provided evidence that an insertion, in the absence of an allelic counterpart, could scan the entire genome for homologous counterparts with which to pair. Furthermore, the unpaired (hemizygous) architectures could accelerate ectopic recombination between itself and interchromosomal counterparts. We suggest that the ectopic recombination accelerated by hemizygous architectures may be a general mechanism for interchromosomal recombination through ubiquitously dispersed repeat sequences in plants, ultimately contributing to genetic renovation and eukaryotic evolution.

  18. Otological Findings Ten Years after Myringotomy with Tympanostomy Tube Insertion

    Directory of Open Access Journals (Sweden)

    Ali Goljanian Tabrizi

    2011-01-01

    Full Text Available Introduction: To study the long-term complications of tympanostomy tube insertion in young children 10 years after surgery.   Materials and Methods: In September 2011, the medical records of all patients who had undergone myringotomy with tympanostomy tube insertion between February 2000 and March 2001 at the two general hospitals of Isfahan University of Medical Sciences were studied. Of the 98 patients who fulfilled the inclusion criteria, 82 patients agreed to participate and were enrolled in the study. The complications of the operation were evaluated in these patients.   Results: Of the 164 ears that were operated on, myringosclerosis was found in 17.1%, atrophy of the tympanic membrane in 1.2%, permanent perforation of the tympanic membrane in 0.6% and tympanic membrane atelectasis in 0.6%. None of the patients developed cholesteatoma as a complication of tympanostomy tube insertion.   Conclusion:  Considering the low risk of serious complications after 10 years, tympanostomy tube insertion is a safe and effective treatment option in the treatment of otitis media with effusion.

  19. Root cause of incomplete control rod insertions at Westinghouse reactors

    Energy Technology Data Exchange (ETDEWEB)

    Ray, S. [Westinghouse, Monroeville, PA (United States)

    1997-01-01

    Within the past year, incomplete RCCA insertions have been observed on high burnup fuel assemblies at two Westinghouse PWRs. Initial tests at the Wolf Creek site indicated that the direct cause of the incomplete insertions observed at Wolf Creek was excessive fuel assembly thimble tube distortion. Westinghouse committed to the NRC to perform a root cause analysis by the end of August, 1996. The root cause analysis process used by Westinghouse included testing at ten sites to obtain drag, growth and other characteristics of high burnup fuel assemblies. It also included testing at the Westinghouse hot cell of two of the Wolf Creek incomplete insertion assemblies. A mechanical model was developed to calculate the response of fuel assemblies when subjected to compressive loads. Detailed manufacturing reviews were conducted to determine if this was a manufacturing related issue. In addition, a review of available worldwide experience was performed. Based on the above, it was concluded that the thimble tube distortion observed on the Wolf Creek incomplete insertion assemblies was caused by unusual fuel assembly growth over and above what would typically be expected as a result of irradiation exposure. It was determined that the unusual growth component is a combination of growth due to oxide accumulation and accelerated growth, and would only be expected in high temperature plants on fuel assemblies that see long residence times and high power duties.

  20. PRODUCTION OF CAST DIE INSERTS FOR HOT STRAINING

    Directory of Open Access Journals (Sweden)

    L. R. Dudetskaja

    2009-01-01

    Full Text Available The paper discusses distinctive design features of casting molds and technological aspects of producing cast inserts from 5ХНМЛ pressed steel. The designs of long-life metal shell molds are described. They ensure saving of molding material, increase of accepted material and improvement of quality of castings.

  1. Insertion and deletion mutagenesis of the human cytomegalovirus genome

    Energy Technology Data Exchange (ETDEWEB)

    Spaete, R.R.; Mocarski, E.S.

    1987-10-01

    Studies on human cytomegalovirus (CMV) have been limited by a paucity of molecular genetic techniques available for manipulating the viral genome. The authors have developed methods for site-specific insertion and deletion mutagenesis of CMV utilizing a modified Escherichia coli lacZ gene as a genetic marker. The lacZ gene was placed under the control of the major ..beta.. gene regulatory signals and inserted into the viral genome by homologous recombination, disrupting one of two copies of this ..beta.. gene within the L-component repeats of CMV DNA. They observed high-level expression of ..beta..-galactosidase by the recombinant in a temporally authentic manner, with levels of this enzyme approaching 1% of total protein in infected cells. Thus, CMV is an efficient vector for high-level expression of foreign gene products in human cells. Using back selection of lacZ-deficient virus in the presence of the chromogenic substrate 5-bromo-4-chloro-3-indolyl ..beta..-D-galactoside, they generated random endpoint deletion mutants. Analysis of these mutant revealed that CMV DNA sequences flanking the insert had been removed, thereby establishing this approach as a means of determining whether sequences flanking a lacZ insertion are dispensable for viral growth. In an initial test of the methods, they have shown that 7800 base pairs of one copy of L-component repeat sequences can be deleted without affecting viral growth in human fibroblasts.

  2. Folding and insertion thermodynamics of the transmembrane WALP peptide.

    Science.gov (United States)

    Bereau, Tristan; Bennett, W F Drew; Pfaendtner, Jim; Deserno, Markus; Karttunen, Mikko

    2015-12-28

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA)n (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide's insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum-in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence.

  3. Allelic prevalence of intron 3 insertion/deletion genetic ...

    African Journals Online (AJOL)

    Leila Fallahzadeh-Abarghooei

    2015-03-18

    Mar 18, 2015 ... genetic polymorphism of DNA double-strand break repair gene ..... [12] Amirshahi P, Sunderland E, Farhud DD, Tavakoli SH, · Daneshmand P ... [17] Saadat M. Distribution of ACE insertion/deletion (I/D) · polymorphism in ...

  4. Engine valve and seat insert wear study with a simulator

    Institute of Scientific and Technical Information of China (English)

    Y.S.Wang; S.Narasimhan

    2001-01-01

    The demands on higher performance and the increasing use of alternative fuels chal-lenge engine valves now with greater wear problems than before. A seat wear simulator was builtto evaluate the compatibility and wear of valve and seat insert. The rig test results have been suc-cessfully correlated with engine test results. In this study, intake valves made from Sil 1 materialwere treated with salt bath nitride processes and tested against six different insert materials. Wearresistance of these combinations was ranked and compared to the Sil 1 valve without nitriding.The test results demonstrate that nitriding improved valve seat wear resistance. In the total valveseat recession ranking, the combination of nitrided Sil 1 valve against T 400 insert exhibited theleast total recession among the nineteen combinations of valve and insert tested. The results indi-cate that the valve seat wear mechanisms are a complex combination of adhesion and shearstrain. The nitrides in the compound layer of nitrided valves gave strong atomic bonding, higherhardness, compressive residual stresses, and possible low friction, thus resulted in the superiorwear performance.

  5. Mitochondrial DNA insertions in the nuclear horse genome.

    Science.gov (United States)

    Nergadze, S G; Lupotto, M; Pellanda, P; Santagostino, M; Vitelli, V; Giulotto, E

    2010-12-01

    The insertion of mitochondrial DNA in the nuclear genome generates numts, nuclear sequences of mitochondrial origin. In the horse reference genome, we identified 82 numts and showed that the entire horse mitochondrial DNA is represented as numts without gross bias. Numts were inserted in the horse nuclear genome at random sites and were probably generated during the repair of DNA double-strand breaks. We then analysed 12 numt loci in 20 unrelated horses and found that null alleles, lacking the mitochondrial DNA insertion, were present at six of these loci. At some loci, the null allele is prevalent in the sample analysed, suggesting that, in the horse population, the number of numt loci may be higher than 82 present in the reference genome. Contrary to humans, the insertion polymorphism of numts is extremely frequent in the horse population, supporting the hypothesis that the genome of this species is in a rapidly evolving state. © 2010 The Authors, Journal compilation © 2010 Stichting International Foundation for Animal Genetics.

  6. Surgical insertion of transmitters and telemetry methods in fisheries research

    DEFF Research Database (Denmark)

    Rub, A. Michelle Wargo; Jepsen, Niels; Liedtke, Theresa L.

    2014-01-01

    ) will be described. Effects of surgical insertion of transmitters (ie, tagging) and aspects of the surgical implantation process where collaboration and professional exchanges among nonveterinarian researchers and veterinarians may be most fruitful will be discussed. Although this report focuses on surgical...

  7. Selective insertion of sulfur dioxide reduction intermediates on graphene oxide.

    Science.gov (United States)

    Humeres, Eduardo; Debacher, Nito A; Smaniotto, Alessandra; de Castro, Karen M; Benetoli, Luís O B; de Souza, Eduardo P; Moreira, Regina de F P M; Lopes, Cristiane N; Schreiner, Wido H; Canle, Moisés; Santaballa, J Arturo

    2014-04-22

    Graphite microparticles (d50 6.20 μm) were oxidized by strong acids, and the resultant graphite oxide was thermally exfoliated to graphene oxide sheets (MPGO, C/O 1.53). Graphene oxide was treated with nonthermal plasma under a SO2 atmosphere at room temperature. The XPS spectrum showed that SO2 was inserted only as the oxidized intermediate at 168.7 eV in the S 2p region. Short thermal shocks at 600 and 400 °C, under an Ar atmosphere, produced reduced sulfur and carbon dioxide as shown by the XPS spectrum and TGA analysis coupled to FTIR. MPGO was also submitted to thermal reaction with SO2 at 630 °C, and the XPS spectrum in the S 2p region at 164.0 eV showed that this time only the nonoxidized episulfide intermediate was inserted. Plasma and thermal treatment produced a partial reduction of MPGO. The sequence of thermal reaction followed by plasma treatment inserted both sulfur intermediates. Because oxidized and nonoxidized intermediates have different reactivities, this selective insertion would allow the addition of selective types of organic fragments to the surface of graphene oxide.

  8. Tool life of diamond inserts after laser assisted turning of cemented carbides

    Directory of Open Access Journals (Sweden)

    Kieruj Piotr

    2017-01-01

    Full Text Available The paper presents results and discussion on parameters influence on tool life when turning laser cladded cemented carbides under laser assisted machining (LAM conditions. The layers are known as Technolase 30S. This material is widely recognized as hard-to-cut. The experimental investigation was carried out with diamond inserts. The laser power density, feed rate and laser scanning speed were analysed. Flank wear (VBc indicator was measured and cutting tool life was calculated. It was proved that Technolase 30S can be machined with LAM technology. The laser enhanced turning is more efficient than conventional turning and grinding.

  9. SU-E-T-64: A Programmable Moving Insert for the ArcCHECK Phantom for Dose Verification of Respiratory-Gated VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Gaede, S; Jordan, K [London Regional Cancer Program, London, ON (United Kingdom); Western University, London, ON (United Kingdom); Young, H [University of Waterloo, Waterloo, ON (Canada); Mulligan, M [London Regional Cancer Program, London, ON (United Kingdom)

    2015-06-15

    Purpose: To present a customized programmable moving insert for the ArcCHECK™ phantom that can, in a single delivery, check both entrance dosimetry, while simultaneously verifying the delivery of respiratory-gated VMAT. Methods: The cylindrical motion phantom uses a computer-controlled stepping motor to move an insert inside a stationery sleeve. Insert motion is programmable and can include rotational motion in addition to linear motion along the axis of the cylinder. The sleeve fits securely in the bore of the ArcCHECK™. Interchangeable inserts, including an A1SL chamber, optically-stimulated luminescence dosimeters, radiochromic film, or 3D gels, allow this combination to be used for commissioning, routine quality assurance, and patient-specific dosimetric verification of respiratory-gated VMAT. Before clinical implementation, the effect of a moving insert on the ArcCHECK™ measurements was considered. First, the measured dose to the ArcCHECK™ containing multiple inserts in the static position was compared to the calculated dose during multiple VMAT treatment deliveries. Then, dose was measured under both sinusoidal and real-patient motion conditions to determine any effect of the moving inserts on the ArcCHECK™ measurements. Finally, dose was measured during gated VMAT delivery to the same inserts under the same motion conditions to examine any effect of various beam “on-and-off” and dose rate ramp “up-and-down”. Multiple comparisons between measured and calculated dose to different inserts were also considered. Results: The pass rate for the static delivery exceeded 98% for all measurements (3%/3mm), suggesting a valid setup for entrance dosimetry. The pass rate was not altered for any measurement delivered under motion conditions. A similar Result was observed under gated VMAT conditions, including agreement of measured and calculated dose to the various inserts. Conclusion: Incorporating a programmable moving insert within the Arc

  10. Cochlear implant insertion forces in microdissected human cochlea to evaluate a prototype array.

    Science.gov (United States)

    Nguyen, Yann; Miroir, Mathieu; Kazmitcheff, Guillaume; Sutter, Jasmine; Bensidhoum, Morad; Ferrary, Evelyne; Sterkers, Olivier; Bozorg Grayeli, Alexis

    2012-01-01

    Cochlear implant array insertion forces are potentially related to cochlear trauma. We compared these forces between a standard (Digisonic SP; Neurelec, Vallauris, France) and an array prototype (Neurelec) with a smaller diameter. The arrays were inserted by a mechatronic tool in 23 dissected human cochlea specimens exposing the basilar membrane. The array progression under the basilar membrane was filmed together with dynamic force measurements. Insertion force profiles and depth of insertion were compared. The recordings showed lower insertion forces beyond 270° of insertion and deeper insertions with the thin prototype array. This will potentially allow larger cochlear coverage with less trauma.

  11. Experimental investigation on flank wear and tool life, cost analysis and mathematical model in turning hardened steel using coated carbide inserts

    Directory of Open Access Journals (Sweden)

    Ashok Kumar Sahoo

    2013-10-01

    Full Text Available Turning hardened component with PCBN and ceramic inserts have been extensively used recently and replaces traditional grinding operation. The use of inexpensive multilayer coated carbide insert in hard turning is lacking and hence there is a need to investigate the potential and applicability of such tools in turning hardened steels. An attempt has been made in this paper to have a study on turning hardened AISI 4340 steel (47 ± 1 HRC using coated carbide inserts (TiN/TiCN/Al2O3/ZrCN under dry environment. The aim is to assess the tool life of inserts and evolution of flank wear with successive machining time. From experimental investigations, the gradual growth of flank wear for multilayer coated insert indicates steady machining without any premature tool failure by chipping or fracturing. Abrasion is found to be the dominant wear mechanisms in hard turning. Tool life of multilayer coated carbide inserts has been found to be 31 minute and machining cost per part is Rs.3.64 only under parametric conditions chosen i.e. v = 90 m/min, f = 0.05 mm/rev and d = 0.5 mm. The mathematical model shows high determination coefficient, R2 (99% and fits the actual data well. The predicted flank wear has been found to lie very close to the experimental value at 95% confidence level. This shows the potential and effectiveness of multilayer coated carbide insert used in hard turning applications.

  12. Mos1 transposon-based transformation of fish cell lines using baculoviral vectors

    Energy Technology Data Exchange (ETDEWEB)

    Yokoo, Masako [Laboratory of Applied Molecular Entomology, Division of Applied Bioscience, Research Faculty of Agriculture, Hokkaido University, Sapporo 060-8589 (Japan); Fujita, Ryosuke [Laboratory of Applied Molecular Entomology, Division of Applied Bioscience, Research Faculty of Agriculture, Hokkaido University, Sapporo 060-8589 (Japan); Innate Immunity Laboratory, Graduate School of Life Science and Creative Research Institution, Hokkaido University, Sapporo 001-0021 (Japan); Nakajima, Yumiko [Functional Genomics Group, COMB, Tropical Biosphere Research Center, University of the Ryukyus, Okinawa 903-0213 (Japan); Yoshimizu, Mamoru; Kasai, Hisae [Faculty of Fisheries Sciences, Hokkaido University, Hakodate 041-8611 (Japan); Asano, Shin-ichiro [Laboratory of Applied Molecular Entomology, Division of Applied Bioscience, Research Faculty of Agriculture, Hokkaido University, Sapporo 060-8589 (Japan); Bando, Hisanori, E-mail: hban@abs.agr.hokudai.ac.jp [Laboratory of Applied Molecular Entomology, Division of Applied Bioscience, Research Faculty of Agriculture, Hokkaido University, Sapporo 060-8589 (Japan)

    2013-09-13

    Highlights: •The baculovirus vector infiltrates the cells of economic important fishes. •Drosophila Mos1 transposase expressed in fish cells maintains its ability to localize to the nucleus. •The baculoviral vector carrying Mos1 is a useful tool to stably transform fish cells. -- Abstract: Drosophila Mos1 belongs to the mariner family of transposons, which are one of the most ubiquitous transposons among eukaryotes. We first determined nuclear transportation of the Drosophila Mos1-EGFP fusion protein in fish cell lines because it is required for a function of transposons. We next constructed recombinant baculoviral vectors harboring the Drosophila Mos1 transposon or marker genes located between Mos1 inverted repeats. The infectivity of the recombinant virus to fish cells was assessed by monitoring the expression of a fluorescent protein encoded in the viral genome. We detected transgene expression in CHSE-214, HINAE, and EPC cells, but not in GF or RTG-2 cells. In the co-infection assay of the Mos1-expressing virus and reporter gene-expressing virus, we successfully transformed CHSE-214 and HINAE cells. These results suggest that the combination of a baculovirus and Mos1 transposable element may be a tool for transgenesis in fish cells.

  13. A transposon-based analysis of gene mutations related to skin cancer development.

    Science.gov (United States)

    Quintana, Rita M; Dupuy, Adam J; Bravo, Ana; Casanova, M Llanos; Alameda, Josefa P; Page, Angustias; Sánchez-Viera, Miguel; Ramírez, Angel; Navarro, Manuel

    2013-01-01

    Nonmelanoma skin cancer (NMSC) is by far the most frequent type of cancer in humans. NMSC includes several types of malignancies with different clinical outcomes, the most frequent being basal and squamous cell carcinomas. We have used the Sleeping Beauty transposon/transposase system to identify somatic mutations associated with NMSC. Transgenic mice bearing multiple copies of a mutagenic Sleeping Beauty transposon T2Onc2 and expressing the SB11 transposase under the transcriptional control of regulatory elements from the keratin K5 promoter were treated with TPA, either in wild-type or Ha-ras mutated backgrounds. After several weeks of treatment, mice with transposition developed more malignant tumors with decreased latency compared with control mice. Transposon/transposase animals also developed basal cell carcinomas. Genetic analysis of the transposon integration sites in the tumors identified several genes recurrently mutated in different tumor samples, which may represent novel candidate cancer genes. We observed alterations in the expression levels of some of these genes in human tumors. Our results show that inactivating mutations in Notch1 and Nsd1, among others, may have an important role in skin carcinogenesis.

  14. Sleeping Beauty transposon-based system for rapid generation of HBV-replicating stable cell lines.

    Science.gov (United States)

    Wu, Yong; Zhang, Tian-Ying; Fang, Lin-Lin; Chen, Zi-Xuan; Song, Liu-Wei; Cao, Jia-Li; Yang, Lin; Yuan, Quan; Xia, Ning-Shao

    2016-08-01

    The stable HBV-replicating cell lines, which carry replication-competent HBV genome stably integrated into the genome of host cell, are widely used to evaluate the effects of antiviral agents. However, current methods to generate HBV-replicating cell lines, which are mostly dependent on random integration of foreign DNA via plasmid transfection, are less-efficient and time-consuming. To address this issue, we constructed an all-in-one Sleeping Beauty transposon system (denoted pTSMP-HBV vector) for robust generation of stable cell lines carrying replication-competent HBV genome of different genotype. This vector contains a Sleeping Beauty transposon containing HBV 1.3-copy genome with an expression cassette of the SV40 promoter driving red fluorescent protein (mCherry) and self-cleaving P2A peptide linked puromycin resistance gene (PuroR). In addition, a PGK promoter-driven SB100X hyperactive transposase cassette is placed in the outside of the transposon in the same plasmid.The HBV-replicating stable cells could be obtained from pTSMP-HBV transfected HepG2 cells by red fluorescence-activated cell sorting and puromycin resistant cell selection within 4-week. Using this system, we successfully constructed four cell lines carrying replication-competent HBV genome of genotypes A-D. The replication and viral protein expression profiles of these cells were systematically characterized. In conclusion, our study provides a high-efficiency strategy to generate HBV-replicating stable cell lines, which may facilitate HBV-related virological study.

  15. A large format in operando wound cell for analysing the structural dynamics of lithium insertion materials

    Science.gov (United States)

    Brant, William R.; Roberts, Matthew; Gustafsson, Torbjörn; Biendicho, Jordi Jacas; Hull, Stephen; Ehrenberg, Helmut; Edström, Kristina; Schmid, Siegbert

    2016-12-01

    This paper presents a large wound cell for in operando neutron diffraction (ND) from which high quality diffraction patterns are collected every 15 min while maintaining conventional electrochemical performance. Under in operando data collection conditions the oxygen atomic displacement parameters (ADPs) and cell parameters were extracted for Li0.18Sr0.66Ti0.5Nb0.5O3. Analysis of diffraction data collected under in situ conditions revealed that the lithium is located on the (0.5 0.5 0) site, corresponding to the 3c Wyckoff position in the cubic perovskite unit cell, after the cell is discharged to 1 V. When the cell is discharged under potentiostatic conditions the quantity of lithium on this site increases, indicating a potential position where lithium becomes pinned in the thermodynamically stable phase. During this potentiostatic step the oxygen ADPs reduce significantly. On discharge, however, the oxygen ADPs were observed to increase gradually as more lithium is inserted into the structure. Finally, the rate of unit cell expansion changed by ∼44% once the lithium content approached ∼0.17 Li per formula unit. A link between lithium content and degree of mobility, disorder of the oxygen positions and changing rate of unit cell expansion at various stages during lithium insertion and extraction is thus presented.

  16. Surface Roughness Prediction Model using Zirconia Toughened Alumina (ZTA) Turning Inserts: Taguchi Method and Regression Analysis

    Science.gov (United States)

    Mandal, Nilrudra; Doloi, Biswanath; Mondal, Biswanath

    2016-01-01

    In the present study, an attempt has been made to apply the Taguchi parameter design method and regression analysis for optimizing the cutting conditions on surface finish while machining AISI 4340 steel with the help of the newly developed yttria based Zirconia Toughened Alumina (ZTA) inserts. These inserts are prepared through wet chemical co-precipitation route followed by powder metallurgy process. Experiments have been carried out based on an orthogonal array L9 with three parameters (cutting speed, depth of cut and feed rate) at three levels (low, medium and high). Based on the mean response and signal to noise ratio (SNR), the best optimal cutting condition has been arrived at A3B1C1 i.e. cutting speed is 420 m/min, depth of cut is 0.5 mm and feed rate is 0.12 m/min considering the condition smaller is the better approach. Analysis of Variance (ANOVA) is applied to find out the significance and percentage contribution of each parameter. The mathematical model of surface roughness has been developed using regression analysis as a function of the above mentioned independent variables. The predicted values from the developed model and experimental values are found to be very close to each other justifying the significance of the model. A confirmation run has been carried out with 95 % confidence level to verify the optimized result and the values obtained are within the prescribed limit.

  17. Open Surgical Insertion of Tenkchoff Straight Catheter Without Guide Wire

    Institute of Scientific and Technical Information of China (English)

    Shi-feng Yang; Wu-jun Xue; Ai-ping Yin; Li-yi Xie; Wan-hong Lu

    2013-01-01

    Objective To compare the clinical outcomes of open surgical peritoneal dialysiscatheter(PDC) insertion with guide wireand the outcomesof PDC insertion without guide wire.Methods Data of the patients receiving open surgical Tenkchoff straight catheter insertion in our department from January 2005 to January 2011 were retrospectively analyzed.The 117 patients in whom PDC insertion was conducted with the guidance of guide wire were enrolled into group A, and the 121 cases receiving PDC insertion without guide wire wereenrolled into group B.The incidences of post-operative complications (catheter obstruction,catheter displacement, bloody dialysate, and dialysate leakage), catheter survival, and patientsurvival rates were compared between the 2 groups.Results The baseline characteristics (gender, age, body mass index, prothrombin time,activated partialthromboplastin time,platelet count,serum creatinine,follow-up time,primarydiseases, and outcomes) of the 2 groups were comparable (allP>0.05). In post-operativecomplications, only the incidence of early bloody dialysate showed significant difference, being16.2% in groupA and 7.4% in group B (P=0.04). Catheter and patient survival rates werenot significantly different between the two groups. Overweight patientsshowed a higherincidence of catheter obstruction compared with normal weight patients [16.0% (4/25) vs. 3.3% (7/213),P=0.02], but no differencesin post-operative complications werefound among overweight patientsbetween the 2 groups.Conclusions Open surgical Tenkchoff straightcatheterinsertion without guide wire does not lead to higher risk of post-operative complications and catheter removal. It may be an alternativeoption when guide wire is not available.

  18. Is calcaneal inclination higher in patients with insertional Achilles tendinosis? A case-controlled, cross-sectional study.

    Science.gov (United States)

    Shibuya, Naohiro; Thorud, Jakob C; Agarwal, Monica R; Jupiter, Daniel C

    2012-01-01

    Insertional Achilles tendinosis is a condition where a patient complains of isolated pain at the Achilles tendon insertion site due to intratendinous degeneration. It has been suggested that this condition is associated with cavus foot deformity. However, to our knowledge, there is no study that has confirmed this observation. We carried out a cross-sectional, case-controlled study to explore the association of increased calcaneal inclination-a surgically important characteristic of cavus foot deformity-with insertional Achilles tendinosis. Patients with Achilles tendinosis and matched controls without the pathology were compared. Although a statistically significant difference was detected in calcaneal inclination angle between these 2 groups (p = .038), we felt that the difference was not clinically significant (calcaneal inclination angle = 20.9 vs. 18.9, respectively). Within the limitations of the study, we conclude that there is no clinically significant difference in calcaneal inclination between those with or without insertional Achilles tendinosis. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Analysis of Primary Stability of Dental Implants Inserted in Different Substrates Using the Pullout Test and Insertion Torque

    Directory of Open Access Journals (Sweden)

    Nathalia Ferraz Oliscovicz

    2013-01-01

    Full Text Available The aim of the study was to evaluate mechanical behavior of implants inserted in three substrates, by measuring the pullout strength and the relative stiffness. 32 implants (Master Porous-Conexao, cylindrical, external hexagon, and surface treatment were divided into 4 groups (n=8: pig rib bone, polyurethane Synbone, polyurethane Nacional 40 PCF, and pinus wood. Implants were installed with the exact distance of 5 mm of another implant. The insertion torque (N·cm was quantified using the digital Kratos torque meter and the pullout test (N was performed by an axial traction force toward the long axis of the implant (2 min/mm through mount implant devices attached to a piece adapted to a load cell of 200 Kg of a universal testing machine (Emic DL10000. Data of insertion torque and maximum pullout force were submitted to one-way ANOVA and Bonferroni tests (α=0.05. Polyurethane Nacional 40 PCF and pinus wood showed the highest values of insertion torque and pullout force, with significant statistical difference (P<0.05 with other groups. The analysis showed stiffness materials with the highest values for primary stability.

  20. Controlling the electronic and geometric structures of 2D insertions to realize high performance metal/insertion-MoS2 sandwich interfaces.

    Science.gov (United States)

    Su, Jie; Feng, Liping; Zeng, Wei; Liu, Zhengtang

    2017-06-08

    Metal/insertion-MoS2 sandwich interfaces are designed to reduce the Schottky barriers at metal-MoS2 interfaces. The effects of geometric and electronic structures of two-dimensional (2D) insertion materials on the contact properties of metal/insertion-MoS2 interfaces are comparatively studied by first-principles calculations. Regardless of the geometric and electronic structures of 2D insertion materials, Fermi level pinning effects and charge scattering at the metal/insertion-MoS2 interface are weakened due to weak interactions between the insertion and MoS2 layers, no gap states and negligible structural deformations for MoS2 layers. The Schottky barriers at metal/insertion-MoS2 interfaces are induced by three interface dipoles and four potential steps that are determined by the charge transfers and structural deformations of 2D insertion materials. The lower the electron affinities of 2D insertion materials, the more are the electrons lost from the Sc surface, resulting in lower n-type Schottky barriers at Sc/insertion-MoS2 interfaces. The larger the ionization potentials and the thinner the thicknesses of 2D insertion materials, the fewer are the electrons that accumulate at the Pt surface, leading to lower p-type Schottky barriers at Pt/insertion-MoS2 interfaces. All Sc/insertion-MoS2 interfaces exhibited ohmic characters. The Pt/BN-MoS2 interface exhibits the lowest p-type Schottky barrier of 0.52 eV due to the largest ionization potential (∼6.88 eV) and the thinnest thickness (single atomic layer thickness) of BN. These results in this work are beneficial to understand and design high performance metal/insertion-MoS2 interfaces through 2D insertion materials.

  1. Assessment of Insertion Sequence Mobilization as an Adaptive Response to Oxidative Stress in Acinetobacter baumannii Using IS-seq.

    Science.gov (United States)

    Wright, Meredith S; Mountain, Stephanie; Beeri, Karen; Adams, Mark D

    2017-05-01

    Insertion sequence (IS) elements are found throughout bacterial genomes and contribute to genome variation by interrupting genes or altering gene expression. Few of the more than 30 IS elements described in Acinetobacter baumannii have been characterized for transposition activity or expression effects. A targeted sequencing method, IS-seq, was developed to efficiently map the locations of new insertion events in A. baumannii genomes and was used to identify novel IS sites following growth in the presence of hydrogen peroxide, which causes oxidative stress. Serial subculture in the presence of subinhibitory concentrations of hydrogen peroxide led to rapid selection of cells carrying an ISAba1 element upstream of the catalase-peroxidase gene katG Several additional sites for the elements ISAba1, ISAba13, ISAba25, ISAba26, and ISAba125 were found at low abundance after serial subculture, indicating that each element is active and contributes to genetic variation that may be subject to selection. Following hydrogen peroxide exposure, rapid changes in gene expression were observed in genes related to iron homeostasis. The IS insertions adjacent to katG resulted in more than 20-fold overexpression of the gene and increased hydrogen peroxide tolerance.IMPORTANCE Insertion sequences (IS) contribute to genomic and phenotypic variation in many bacterial species, but little is known about how transposition rates vary among elements or how selective pressure influences this process. A new method for identifying new insertion locations that arise under experimental growth conditions in the genome, termed IS-seq, was developed and tested with cells grown in the presence of hydrogen peroxide, which causes oxidative stress. Gene expression changes in response to hydrogen peroxide exposure are similar to those observed in other species and include genes that control free iron concentrations. New IS insertions adjacent to a gene encoding a catalase enzyme confirm that IS elements

  2. The insert region of the Rac GTPases is dispensable for activation of superoxide-producing NADPH oxidases.

    Science.gov (United States)

    Miyano, Kei; Koga, Hirofumi; Minakami, Reiko; Sumimoto, Hideki

    2009-08-13

    Rac1 and Rac2, which belong to the Rho subfamily of Ras-related GTPases, play an essential role in activation of gp91phox/Nox2 (cytochrome b-245, beta polypeptide; also known as Cybb), the catalytic core of the superoxide-producing NADPH oxidase in phagocytes. Rac1 also contributes to activation of the non-phagocytic oxidases Nox1 (NADPH oxidase 1) and Nox3 (NADPH oxidase 3), each related closely to gp91phox/Nox2. It has remained controversial whether the insert region of Rac (amino acids 123-135), unique to the Rho subfamily proteins, is involved in gp91phox/Nox2 activation. In the present study we show that removal of the insert region from Rac1 neither affects activation of gp91phox/Nox2, which is reconstituted under cell-free and whole-cell conditions, nor blocks its localization to phagosomes during ingestion of IgG-coated beads by macrophage-like RAW264.7 cells. The insert region of Rac2 is also dispensable for gp91phox/Nox2 activation at the cellular level. Although Rac2, as well as Rac1, is capable of enhancing superoxide production by Nox1 and Nox3, the enhancements by the two GTPases are both independent of the insert region. We also demonstrate that Rac3, a third member of the Rac family in mammals, has an ability to activate the three oxidases and that the activation does not require the insert region. Thus the insert region of the Rac GTPases does not participate in regulation of the Nox family NADPH oxidases.

  3. Lesion insertion in the projection domain: Methods and initial results

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia, E-mail: mccollough.cynthia@mayo.edu [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2015-12-15

    Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically

  4. GBLHT: a GPU-Accelerated Linear Hash Table with Batch Insertion%GBLHT:—种GPU加速的批量插入线性哈希表

    Institute of Scientific and Technical Information of China (English)

    黄玉龙; 奚建清; 张平健; 方晓霖; 刘勇

    2012-01-01

    In order to improve the insertion performance of linear Hash table known as an effective index structure, the existing insertion methods are analyzed, and a linear Hash table GBLHT with batch records insertion, which is combined with the CUDA parallel programming model, is designed and implemented. With the help of the atomic function atomic Add, GBLHT takes full advantage of the high parallel throughput of graphic processing unit (GPU) to implement the lock-free batch insertion of massive records. Some experiments are then carried out to compare the insertion performances of the traditional serial insertion method, the CPU-based batch insertion method and GBLHT. The results show that, under various parameter conditions, the insertion performance of GBLHT is 7 ~ 14 times higher than that of the traditional serial method, and is 3 ~ 6 times higher than that of the CPU-based batch insertion method with four threads.%为改善线性哈希表这一有效索引结构的插入性能,在分析现有方法的基础上,结合CUDA并行编程模型,设计并实现了一种基于GPU的批量插入线性哈希表GBLHT;借助原子函数atomicAdd,GBLHT可以充分利用GPU强大的并行吞吐量来实现大规模记录的无锁批量插入;通过实验对比传统串行插入方法、CPU批量插入方法以及GBLHT的插入性能,发现在不同参数设置条件下,GBLHT的插入性能比传统串行方式提升了7~14倍,与4线程的CPU批量插入方法相比则提升了3~6倍.

  5. Theoretical Prediction on the Germylenoid HB=GeLiF and Its Insertion Reaction with R-H(R = F,OH,NH_2)

    Institute of Scientific and Technical Information of China (English)

    李文佐; 杨凤霞; 程建波; 李庆忠; 宫宝安

    2012-01-01

    In the present work we investigated a novel triplet ground-state germylenoid HB=GeLiF as well as its insertion reactions with RH(R = F,OH and NH2) using the DFT B3LYP and QCISD methods for the first time.Geometry optimization calculations show that the triplet HB=GeLiF has three equilibrium structures,in which the four-membered ring structure is the most stable with the lowest energy.All mechanisms of the three insertion reactions of germylenoid HB=GeLiF with RH(R = F,OH,and NH2) are identical to each other.Based on the calculated results,it is concluded that under the same conditions the insertion reactions should occur easily in the order of H-F H-OH H-NH2.In THF solvent the insertion reactions get more difficult than in the gas phase.

  6. Identification of new IS711 insertion sites in Brucella abortus field isolates

    Directory of Open Access Journals (Sweden)

    Moriyón Ignacio

    2011-08-01

    Full Text Available Abstract Background Brucellosis is a zoonosis caused by Brucella spp., a group of highly homogeneous bacteria. The insertion sequence IS711 is characteristic of these bacteria, and occurs in variable numbers and positions, but always constant within a given species. This species-associated polymorphism is used in molecular typing and identification. Field isolates of B. abortus, the most common species infecting cattle, typically carry seven IS711 copies (one truncated. Thus far, IS711 transposition has only been shown in vitro and only for B. ovis and B. pinnipedialis, two species carrying a high number of IS711 copies, but never in other Brucella species, neither in vitro nor in field strains. Results We found several B. abortus strains isolated from milk and aborted fetuses that carried additional IS711 copies in two hitherto undescribed insertion sites: one in an intergenic region near to the 3' end of a putative lactate permease gene and the other interrupting the sequence of a marR transcriptional regulator gene. Interestingly, the second type of insertion was identified in isolates obtained repeatedly from the same herd after successive brucellosis outbreaks, an observation that proves the stability and virulence of the new genotype under natural conditions. Sequence analyses revealed that the new copies probably resulted from the transposition of a single IS711 copy common to all Brucella species sequenced so far. Conclusions Our results show that the replicative transposition of IS711 can occur under field conditions. Therefore, it represents an active mechanism for the emergence of genetic diversity in B. abortus thus contributing to intra-species genetic polymorphism.

  7. Functional hearing in noise: insert earphones vs. supra-aural headphones.

    Science.gov (United States)

    Ribera, John E

    2007-12-01

    Aviators and aircrew members work in hostile listening environments on a routine basis and rely on their hearing for crew coordination, a critical component of rotary-wing aviation. New technology may assist in this endeavor, but will require aviators to have the ability to not only hear in noise, but also to localize warning and other signals. The Hearing in Noise Test (HINT) assesses functional hearing in noise, but has only been normalized using sound field speakers or supra-aural headphones. There were 60 normal hearing students (30 men and 30 women) from Utah State University who were equally partitioned into 3 groups. Each group was administered the HINT in three test conditions with one of three transducers: 1) THD-39 supra-aural; 2) ER-3A foam inserts; or 3) the communications earplug. Analysis of the data revealed there was no gender difference and no significant differences between scores obtained using the transducers under test in any of the test conditions. Insert-type earphones should be considered for administration of the HINT.

  8. HACRE1, a recently inserted copia-like retrotransposon of sunflower (Helianthus annuus L.).

    Science.gov (United States)

    Buti, M; Giordani, T; Vukich, M; Gentzbittel, L; Pistelli, L; Cattonaro, F; Morgante, M; Cavallini, A; Natali, L

    2009-11-01

    In this paper we report on the isolation and characterization, for the first time, of a complete 6511 bp retrotransposon of sunflower. Considering its protein domain order and sequence similarity to other copia elements of dicotyledons, this retrotransposon was assigned to the copia retrotransposon superfamily and named HACRE1 (Helianthus annuus copia-like retroelement 1). HACRE1 carries 5' and 3' long terminal repeats (LTRs) flanking an internal region of 4661 bp. The LTRs are identical in their sequence except for two deletions of 7 and 5 nucleotides in the 5' LTR. Based on the sequence identity of the LTRs, HACRE1 was estimated to have inserted within the last approximately 84 000 years. The isolated sequence contains a complete open reading frame with only one complete reading frame. The absence of nonsense mutations agrees with the very high sequence identity between LTRs, confirming that HACRE1 insertion is recent. The haploid genome of sunflower (inbred line HCM) contains about 160 copies of HACRE1. This retrotransposon is expressed in leaflets from 7-day-old plantlets under different light conditions, probably in relation to the occurrence of many putative light-related regulatory cis-elements in the LTRs. However, sequenced cDNAs show less variability than HACRE1 genomic sequences, indicating that only a subset of this family is expressed under these conditions.

  9. Insertional hypermutation in mineral oil-induced plasmacytomas.

    Science.gov (United States)

    Knittel, Gero; Metzner, Mirjam; Beck-Engeser, Gabriele; Kan, Ada; Ahrends, Tomasz; Eilat, Dan; Huppi, Konrad; Wabl, Matthias

    2014-09-01

    Unless stimulated by a chronic inflammatory agent, such as mineral oil, plasma cell tumors are rare in young BALB/c mice. This raises the questions: What do inflammatory tissues provide to promote mutagenesis? And what is the nature of mutagenesis? We determined that mineral oil-induced plasmacytomas produce large amounts of endogenous retroelements--ecotropic and polytropic murine leukemia virus and intracisternal A particles. Therefore, plasmacytoma formation might occur, in part, by de novo insertion of these retroelements, induced or helped by the inflammation. We recovered up to ten de novo insertions in a single plasmacytoma, mostly in genes with common retroviral integration sites. Additional integrations accompany tumor evolution from a solid tumor through several generations in cell culture. The high frequency of de novo integrations into cancer genes suggests that endogenous retroelements are coresponsible for plasmacytoma formation and progression in BALB/c mice.

  10. Phase transitions in insertion electrodes for lithium batteries

    Energy Technology Data Exchange (ETDEWEB)

    Thackeray, M. M.

    2000-02-02

    Phase transitions that occur during lithium insertion into layered and framework structures are discussed in the context of their application as positive and negative electrodes in lithium-ion batteries. The discussion is focused on the two-dimensional structures of graphite, LiNi{sub 1{minus}x}M{sub x}O{sub 2} (M = Co, Ti and Mg), and Li{sub 1.2}V{sub 3}O{sub 8}; examples of framework structures with a three-dimensional interstitial space for Li{sup +}-ion transport include the spinel oxides and intermetallic compounds with zinc-blende-type structures. The phase transitions are discussed in terms of their tolerance to lithium insertion and extraction and to the chemical stability of the electrodes in the cell environment.

  11. An overview of the insertion device development at SRRC

    CERN Document Server

    Hwang, C S; Fan, T C; Wang, C; Chen, J R; Chen, C T

    2001-01-01

    Five high performance insertion devices, namely W20, U10, U5, U9 and EPU5.6, have been constructed and installed in the storage ring of the Synchrotron Radiation Research Center (SRRC). Among them, the 2-m-long conventional undulator U10 and the 4-m-long elliptically polarized undulator EPU5.6 were designed and built in-house. These two devices have achieved high magnetic field quality and high spectral performance. To facilitate hard-X-ray experiments, the project of building a superconducting wavelength shifter (SWLS) and a superconducting multi-pole wiggler (SMPW) is ongoing. These two superconducting insertion devices were designed to be cryogen-free.

  12. Amyloid protein unfolding and insertion kinetics on neuronal membrane mimics

    Science.gov (United States)

    Qiu, Liming; Buie, Creighton; Vaughn, Mark; Cheng, Kwan

    2010-03-01

    Atomistic details of beta-amyloid (Aβ ) protein unfolding and lipid interaction kinetics mediated by the neuronal membrane surface are important for developing new therapeutic strategies to prevent and cure Alzheimer's disease. Using all-atom MD simulations, we explored the early unfolding and insertion kinetics of 40 and 42 residue long Aβ in binary lipid mixtures with and without cholesterol that mimic the cholesterol-depleted and cholesterol-enriched lipid nanodomains of neurons. The protein conformational transition kinetics was evaluated from the secondary structure profile versus simulation time plot. The extent of membrane disruption was examined by the calculated order parameters of lipid acyl chains and cholesterol fused rings as well as the density profiles of water and lipid headgroups at defined regions across the lipid bilayer from our simulations. Our results revealed that both the cholesterol content and the length of the protein affect the protein-insertion and membrane stability in our model lipid bilayer systems.

  13. Destabilization of the human epigenome: consequences of foreign DNA insertions.

    Science.gov (United States)

    Weber, Stefanie; Hofmann, Andrea; Herms, Stefan; Hoffmann, Per; Doerfler, Walter

    2015-08-01

    We previously reported changes of DNA methylation and transcription patterns in mammalian cells that carry integrated foreign DNA. Experiments were now designed to assess the epigenetic consequences of inserting a 5.6 kbp plasmid into the human genome. Differential transcription and CpG methylation patterns were compared between transgenomic and nontransgenomic cell clones by using gene chip microarray systems. In 4.7% of the 28.869 gene segments analyzed, transcriptional activities were up- or downregulated in the transgenomic cell clones. Genome-wide profiling revealed differential methylation in 3791 of > 480,000 CpG's examined in transgenomic versus nontransgenomic clones. The data document genome-wide effects of foreign DNA insertions on the epigenetic stability of human cells. Many fields in experimental biology and medicine employ transgenomic or otherwise genome-manipulated cells or organisms without considering the epigenetic consequences for the recipient genomes.

  14. First two barrel ECAL supermodules inserted in CMS HCAL

    CERN Multimedia

    K.Bell

    2006-01-01

    The first two barrel "supermodules" for the CMS Electromagnetic Calorimeter (ECAL) have been inserted into the barrel hadron calorimeter (HCAL) in the experimental hall (called SX5) in Cessy in preparation for the forthcoming magnet test and cosmic challenge (MTCC). Each of the two supermodules contains 1700 lead tungstate crystals in glass-fibre alveolar support structures, with associated avalanche photodiodes (APDs, for scintillation light detection), electronics and cooling system. The barrel ECAL will consist of 36 supermodules, many of which have already been produced (see CERN Bulletin 17-18, 2006). Team from CMS ECAL, CMS Integration and CEA-DAPNIA were involved in the insertion, with the production/integration of the supermodules themselves involving many technicians, engineers and physicists from many institutes. From left to right: Olivier Teller, Maf Alidra and Lucien Veillet.

  15. A morphophonological analysis of the velar insert in Italian verbs

    Directory of Open Access Journals (Sweden)

    Nicola Lampitelli

    2017-05-01

    Full Text Available This paper analyzes a particular group of Italian irregular verbs that are characterized by the insertion of [g] between the root and the inflectional markers. Despite the apparent unetymological status of such a velar insert (Rohlfs 1968, it is shown that the allomorphy of the root depends on the internal organization of the segmental material with respect to a fixed template made of a strict alternation of onsets (C and nuclei (V. The analyses are couched within the CVCV framework (Lowenstamm 1996; Scheer 2004 and are consistent with a syntactic approach to word- formation such as Distributed Morphology (Halle & Marantz 1993; Embick 2010. This article is part of the special collection: Motivating Form in Morpho-Syntax

  16. Convective heat transfer enhancement inside tubes using inserted helical coils

    Science.gov (United States)

    Ali, R. K.; Sharafeldeen, M. A.; Berbish, N. S.; Moawed, M. A.

    2016-01-01

    Convective heat transfer was experimentally investigated in tubes with helical coils inserts in turbulent flow regime within Reynolds number range of 14400 ≤ Re ≤ 42900. The present work aims to extend the experimental data available on wire coil inserts to cover wire diameter ratio from 0.044 to 0.133 and coil pitch ratio from 1 to 5. Uniform heat flux was applied to the external surface of the tube and air was selected as fluid. The effects of Reynolds number and wire diameter and coil pitch ratios on the Nusselt number and friction factor were studied. The enhancement efficiency and performance criteria ranges are of (46.9-82.6%) and (100.1-128%) within the investigated range of the different parameters, respectively. Correlations are obtained for the average Nusselt number and friction factor utilizing the present measurements within the investigated range of geometrical parameters and Re.

  17. [Neonatology nurses' knowledge about Peripherally Inserted Central Venous Catheter].

    Science.gov (United States)

    Belo, Marcela Patricia Macêdo; Silva, Roberta Albuquerque Mello de Castro; Nogueira, Isis Larissa Maia; Mizoguti, Daniele Pereira; Ventura, Claudiane Maria Urbano

    2012-01-01

    The Peripherally Inserted Central Catheter (PICC) has been used as a safe venous access for infants at risk. The aim of this study was to describe the knowledge and practice of nurses from the five public Neonatal Intensive Care Units, of Recife-PE, Brazil, about the use of the PICC. The sample was comprised by 52 nurses; data were collected from January to February/2010. It was found that 64,8% of nurses did not have license for insertion of the PICC. Only two units routinely used the PICC. About the indication of the access, the accuracy was above 70%. In unit B only 8,3% of nurses reported adequate initial location of the catheter tip. It was concluded that is necessary greater incentives to train nurses to use the PICC.

  18. Challenges for Insertion of Structural Nanomaterials in Aerospace Applications

    Science.gov (United States)

    Sochi, Emilie J.

    2012-01-01

    In the two decades since Iijima's report on carbon nanotubes (CNT), there has been great interest in realizing the benefits of mechanical properties observed at the nanoscale in large-scale structures. The weight savings possible due to dramatic improvements in mechanical properties relative to state-of-the-art material systems can be game changing for applications like aerospace vehicles. While there has been significant progress in commercial production of CNTs, major aerospace applications that take advantage of properties offered by this material have yet to be realized. This paper provides a perspective on the technical challenges and barriers for insertion of CNTs as an emerging material technology in aerospace applications and proposes approaches that may reduce the typical timeframe for technology maturation and insertion into aerospace structures.

  19. Invariant Quantum Algorithms for Insertion into an Ordered List

    CERN Document Server

    Farhi, E; Gutmann, S; Sipser, M; Farhi, Edward; Goldstone, Jeffrey; Gutmann, Sam; Sipser, Michael

    1999-01-01

    We consider the problem of inserting one item into a list of N-1 ordered items. We previously showed that no quantum algorithm could solve this problem in fewer than log N/(2 log log N) queries, for N large. We transform the problem into a "translationally invariant" problem and restrict attention to invariant algorithms. We construct the "greedy" invariant algorithm and show numerically that it outperforms the best classical algorithm for various N. We also find invariant algorithms that succeed exactly in fewer queries than is classically possible, and iterating one of them shows that the insertion problem can be solved in fewer than 0.53 log N quantum queries for large N (where log N is the classical lower bound). We don't know whether a o(log N) algorithm exists.

  20. pH-(low)-insertion-peptide (pHLIP) translocation of membrane impermeable phalloidin toxin inhibits cancer cell proliferation.

    Science.gov (United States)

    An, Ming; Wijesinghe, Dayanjali; Andreev, Oleg A; Reshetnyak, Yana K; Engelman, Donald M

    2010-11-23

    We find that pH-(low)-insertion-peptide (pHLIP)-facilitated translocation of phalloidin, a cell-impermeable polar toxin, inhibits the proliferation of cancer cells in a pH-dependent fashion. The monomeric pHLIP inserts its C terminus across a membrane under slightly acidic conditions (pH 6-6.5), forming a transmembrane helix. The delivery construct carries phalloidin linked to its inserting C terminus via a disulfide bond that is cleaved inside cells, releasing the toxin. To facilitate delivery of the polar agent, a lipophilic rhodamine moiety is also attached to the inserting end of pHLIP. After a 3 h incubation at pH 6.1-6.2 with 2-4 μM concentrations of the construct, proliferation in cultures of HeLa, JC, and M4A4 cancer cells is severely disrupted (> 90% inhibition of cell growth). Treated cells also show signs of cytoskeletal immobilization and multinucleation, consistent with the expected binding of phalloidin to F actin, stabilizing the filaments against depolymerization. The antiproliferative effect was not observed without the hydrophobic facilitator (rhodamine). The biologically active delivery construct inserts into 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine lipid bilayers with an apparent pK(a) of ∼6.15, similar to that of the parent pHLIP peptide. Sedimentation velocity experiments show that the delivery construct is predominantly monomeric (> 90%) in solution under the conditions employed to treat cells (pH 6.2, 4 μM). These results provide a lead for antitumor agents that would selectively destroy cells in acidic tumors. Such a targeted approach may reduce both the doses needed for cancer chemotherapy and the side effects in tissues with a normal pH.

  1. Insertion devices at the Swiss Light Source (phase I)

    CERN Document Server

    Schmidt, T; Imhof, A; Patterson, B D; Patthey, L; Quitmann, C; Schulze-Briese, C; Abela, R

    2001-01-01

    The insertion devices under construction for phase I of the Swiss Light Source (SLS) are described. Five undulators and one wiggler will be installed in four straight sections of the third generation 2.4 GeV SLS storage ring, under construction at the Paul Scherrer Institute. To provide undulator radiation in the energy range from 10 eV to 18 keV, both long period and short period, small gap undulators will be installed.

  2. Insertion force in manual and robotic corneal suturing.

    Science.gov (United States)

    Yang, Yang; Xu, Cunliang; Deng, Shijing; Xiao, Jingjing

    2012-03-01

    Due to differences in corneal grafting microsurgery between manual and robotic suturing, new challenges have arisen in testing the insertion force and torque of corneal tissue acting on suturing needles in order to guarantee successful completion of surgical procedures. In order to measure the force during the insertion operation, from the needle entering the cornea through the entry point until the puncturing of the exit point along the circular trajectory, a force measurement system was established, including fresh porcine cornea, a corneal-suturing robot, a circular needle, a micro-forceps manipulator with a force transducer, a computer with a data acquisition board and a medical microscope. The force values in the needle coordinate frames were obtained on the basis of a sensor coordinate frame through D-H coordinate transformation, and an index is proposed here to evaluate the insertion performance. Experiments on both manual and robotic suturing were carried out for comparison. The scale and changes of the needle insertion force were obtained using two different suturing methods. The maximal tangent force in robotic suturing is a little larger than in manual suturing, and the maximal resultant force in robotic suturing is somewhat smaller. Although the difference is not very significant, robotic suturing performs in a more stable way. Moreover, the performance evaluation index M(dmax) (the maximum of square root of the quadratic sum of torque components M(OX) and M(OY)) in robotic suturing is much smaller than that in manual suturing. The force measurement system has been verified to be feasible through experimentation. Compared with conventional manual surgery, robotic suturing has some advantages: more stable suturing, smaller distortion torque and fewer invasions to the corneal tissue, showing that its application in minimally invasive surgery is practical. Copyright © 2011 John Wiley & Sons, Ltd.

  3. Magnetic resonance urography in duplex kidney with ectopic ureteral insertion

    Science.gov (United States)

    Thambidorai, Conjeevaram Rajendrarao; Anuar, Zulfiqar

    2011-01-01

    This is a report on the use of magnetic resonance urography (MRU) in a 6-year-old girl who presented with urinary incontinence. She had a left duplex kidney with poorly functioning upper moiety and ectopic insertion of the dilated upper pole ureter. MRU has been shown to be superior to conventional imaging techniques in delineating poorly functioning moieties of duplex kidneys and ectopic ureters. PMID:21897576

  4. Magnetic resonance urography in duplex kidney with ectopic ureteral insertion

    Directory of Open Access Journals (Sweden)

    Conjeevaram Rajendrarao Thambidorai

    2011-01-01

    Full Text Available This is a report on the use of magnetic resonance urography (MRU in a 6-year-old girl who presented with urinary incontinence. She had a left duplex kidney with poorly functioning upper moiety and ectopic insertion of the dilated upper pole ureter. MRU has been shown to be superior to conventional imaging techniques in delineating poorly functioning moieties of duplex kidneys and ectopic ureters.

  5. The Evolution of Insertion Sequences within Enteric Bacteria

    OpenAIRE

    Lawrence, J G; Ochman, H.; Hartl, D. L.

    1992-01-01

    To identify mechanisms that influence the evolution of bacterial transposons, DNA sequence variation was evaluated among homologs of insertion sequences IS1, IS3 and IS30 from natural strains of Escherichia coli and related enteric bacteria. The nucleotide sequences within each class of IS were highly conserved among E. coli strains, over 99.7% similar to a consensus sequence. When compared to the range of nucleotide divergence among chromosomal genes, these data indicate high turnover and ra...

  6. Epigenetic Suppression of T-DNA Insertion Mutants in Arabidopsis

    Institute of Scientific and Technical Information of China (English)

    Yangbin Gao; Yunde Zhao

    2013-01-01

    T-DNA insertion mutants have been widely used to define gene functions in Arabidopsis and in other plants.Here,we report an unexpected phenomenon of epigenetic suppression of T-DNA insertion mutants in Arabidopsis.When the two T-DNA insertion mutants,yucl-1 and ag-TD,were crossed together,the defects in all of the ag-TD plants in the F2 population were partially suppressed regardless of the presence of yucl-1.Conversion of ag-TD to the suppressed ag-TD (named as ag-TD*) did not follow the laws of Mendelian genetics.The ag-TD* could be stably transmitted for many generations without reverting to ag-TD,and ag-TD* had the capacity to convert ag-TD to ag-TD*.We show that epigenetic suppression of T-DNA mutants is not a rare event,but certain structural features in the T-DNA mutants are needed in order for the suppression to take place.The suppressed T-DNA mutants we observed were all intronic T-DNA mutants and the T-DNA fragments in both the trigger T-DNA as well as in the suppressed T-DNA shared stretches of identical sequences.We demonstrate that the suppression of intronic T-DNA mutants is mediated by trans-interactions between two ToDNA insertions.This work shows that caution is needed when intronic T-DNA mutants are used.

  7. Reverse genetics in Chlamydomonas: a platform for isolating insertional mutants

    OpenAIRE

    de Montaigu Amaury; Magneschi Leonardo; Catalanotti Claudia; Yang Wenqiang; Mus Florence; Pootakham Wirulda; Gonzalez-Ballester David; Higuera Jose J; Prior Matthew; Galván Aurora; Fernandez Emilio; Grossman Arthur R

    2011-01-01

    Abstract A method was developed to identify insertional mutants of Chlamydomonas reinhardtii disrupted for selected target genes. The approach relies on the generation of thousands of transformants followed by PCR-based screenings that allow for identification of strains harboring the introduced marker gene within specific genes of interest. Our results highlight the strengths and limitations of two independent screens that differed in the nature of the marker DNA used (PCR-amplified fragment...

  8. Training on hearing protector insertion improves noise attenuation

    OpenAIRE

    Samelli, Alessandra Giannella; Rocha,Clayton Henrique; Theodósio,Patrícia; Moreira,Renata Rodrigues; Neves-Lobo,Ivone Ferreira

    2015-01-01

    ABSTRACT Purpose: To determine the efficacy of hearing protector insertion by comparing attenuation values measured by objective (MIRE) and subjective (REAT) methods in groups with and without training. Methods: The study included 80 male subjects assigned to experimental (with training) and control (without training) groups. The following procedures were performed: occupational history, objective and subjective assessment of hearing protectors. Only subjects in the experimental group rece...

  9. Evolution of implantable and insertable drug delivery systems.

    Science.gov (United States)

    Kleiner, Lothar W; Wright, Jeremy C; Wang, Yunbing

    2014-05-10

    The paper describes the development of implantable and insertable drug delivery systems (IDDS) from their early stage in the 1960s until the current stage in the 2010s. It gives a detailed summary of non-degradable and biodegradable systems and their applications in different areas such as vascular disease treatment, birth control, cancer treatment, and eye disease treatment. It also describes the development of various implantable pump systems and some other atypical IDDS, the challenges and the future of IDDS.

  10. Accurate Insertion Loss Measurements of the Juno Patch Array Antennas

    Science.gov (United States)

    Chamberlain, Neil; Chen, Jacqueline; Hodges, Richard; Demas, John

    2010-01-01

    This paper describes two independent methods for estimating the insertion loss of patch array antennas that were developed for the Juno Microwave Radiometer instrument. One method is based principally on pattern measurements while the other method is based solely on network analyzer measurements. The methods are accurate to within 0.1 dB for the measured antennas and show good agreement (to within 0.1dB) of separate radiometric measurements.

  11. Non-harmful insertion of data mimicking computer network attacks

    Science.gov (United States)

    Neil, Joshua Charles; Kent, Alexander; Hash, Jr, Curtis Lee

    2016-06-21

    Non-harmful data mimicking computer network attacks may be inserted in a computer network. Anomalous real network connections may be generated between a plurality of computing systems in the network. Data mimicking an attack may also be generated. The generated data may be transmitted between the plurality of computing systems using the real network connections and measured to determine whether an attack is detected.

  12. Removable partial denture with a lateral rotational path of insertion.

    Science.gov (United States)

    Baharav, H; Ben-Ur, Z; Laufer, B Z; Cardash, H S

    1995-08-01

    A removable partial denture with a lateral path of insertion is useful when unsightly facial clasps are objectional to the patient. Rounded rest seat preparations allow extensions of the minor connector to rotate laterally into embrasure undercuts, providing retention. Guiding planes on the contralateral side ensure a different path of withdrawal from the retentive elements. A Kennedy Class IV arch with a long edentulous span is used to illustrate the denture design.

  13. The endometrial bacterial flora following insertion of intrauterine contraceptive device.

    Science.gov (United States)

    Kamar, R; Wajntraub, G; Godfried, L; Czazkes, E; Aloni, T A

    1980-01-01

    Bacteriological cultures of material were collected from the endometrium and cervix of 150 women using the IUD, 75 control women and transfundally from 20 uteri of women who had undergone abdominal hysterectomy. The results show that the IUD does not alter the endometrial flora unless it is left in situ for a period exceeding two years. The transfundal cultures yielded the lowest positive cultures. The relationship of positive culture to the cycle and the period of insertion of IUD is discussed.

  14. The first insertion devices at SSRL - some personal recollections

    Energy Technology Data Exchange (ETDEWEB)

    Winick, H. [Stanford Linear Accelerator Center, CA (United States)

    1995-02-01

    The author recounts his experiences with insertion devices at the Stanford Synchrotron Radiation Laboratory. His first experiences with wigglers occured at the Cambridge Electron Accelerator, and was carried over to SSRL with the proposal for a six pole electromagnetic wiggler. Most modern undulators, and many wigglers are now designed around permanent magnets, and the origin of this transition at SSRL was rather fortuitous and humorous. It reflects some of the personality characteristics of Klaus Halbach.

  15. Sacroiliac secure corridor: analysis for safe insertion of iliosacral screws

    Directory of Open Access Journals (Sweden)

    Henrique Alves Cruz

    2013-08-01

    Full Text Available OBJECTIVE: Posterior pelvic lesions, especially of the sacral-iliac joint, have high mortality and morbidity risks. Definitive fixation is necessary for the joint stabilization, and one option is the sacral percutaneous pinning with screws. Proximity to important structures to this region brings risks to the fixation procedure; therefore, it is important to know the tridimensional anatomy of the pelvis posterior region. Deviations of the surgeon's hand of four degrees may target the screws to those structures; dimorphisms of the upper sacrum and a poor lesion reduction may redound in a screw malpositioning. This study is aimed to evaluate the dimensions of a safe surgical corridor for safe sacroiliac screw insertion and relations with age and sex of the patients. METHOD: One hundred randomly selected pelvis CTs of patients with no pelvic diseases, seen at a tertiary care teaching Hospital. Measurements were made by computer and the safest area for screw insertion was calculated by two methods. The results were expressed in mm (not in degrees, in order to be a further surgical reference. RESULTS: There was a significant size difference in the analyzed sacral vertebra, differing on a wider size in men than in women. There was no significant statistical difference between vertebral size and age. By both methods, a safe area for screw insertion could be defined. CONCLUSION: Age does not influence the width of the surgical corridor. The surgeon has a safe corridor considered narrower when inserting screws in a female pelvis than when in a male one. However, as the smallest vertebra found (feminine was considered for statics, it was concluded that this corridor is 20 mm wide in any direction, taking as a reference the centrum of the vertebra.

  16. Thermodynamic study of benzocaine insertion into different lipid bilayers

    Science.gov (United States)

    Cascales, J. J. López; Costa, S. D. Oliveira; Porasso, R. D.

    2011-10-01

    Despite the general consensus concerning the role played by sodium channels in the molecular mechanism of local anesthetics, the potency of anaesthetic drugs also seems to be related with their solubility in lipid bilayers. In this respect, this work represents a thermodynamic study of benzocaine insertion into lipid bilayers of different compositions by means of molecular dynamics simulation. Thus, the free energy profiles associated with benzocaine insertion into symmetric lipid bilayers composed of different proportions of dipalmitoylphosphatidylcholine and dipalmitoylphosphatidylserine were studied. From the simulation results, a maximum in the free energy (ΔG) profile was measured in the region of the lipid/solution interface. This free energy barrier appears to be very much dependent on the lipid composition of the membrane. On the other hand, the minimum free energy (ΔG) within the bilayer remained almost independent of the lipid composition of the bilayer. By repeating the study at different temperatures, it was seen how the spontaneity of benzocaine insertion into the lipid bilayer is due to an increase in the entropy associated with the process.

  17. Enhancement of Selection, Bubble and Insertion Sorting Algorithm

    Directory of Open Access Journals (Sweden)

    Muhammad Farooq Umar

    2014-07-01

    Full Text Available In everyday life there is a large amount of data to arrange because sorting removes any ambiguities and make the data analysis and data processing very easy, efficient and provides with cost less effort. In this study a set of improved sorting algorithms are proposed which gives better performance and design idea. In this study five new sorting algorithms (Bi-directional Selection Sort, Bi-directional bubble sort, MIDBiDirectional Selection Sort, MIDBidirectional bubble sort and linear insertion sort are presented. Bi-directional Selection Sort and MIDBiDirectional Selection Sort are the enhancement on basic selection sort while Bidirectional bubble sort and MIDBidirectional bubble sort are the enhancement on basic bubble sort by changing the selection and swapping mechanism of data for sorting. Enhanced sorting algorithms reduced the iteration by half and quarter times respectively. Asymptotically complexities of these algorithms are reduced to O (n2/2 and O (n2/4 from O (n2. Linear insertion sort is the enhancement of insertion sort by changing the design of algorithm (convert two loops to one loop. So asymptotically this algorithm is converted to linear time complexity from quadratic complexity. These sorting algorithms are described using C. The proposed algorithms are analyzed using asymptotic analysis and also using machine-running time and compared with their basic sorting algorithms. In this study we also discuss how the performance and complexity can be improved by optimizing the code and design.

  18. Modeling and characterization of partially inserted electrical connector faults

    Science.gov (United States)

    Tokgöz, ćaǧatay; Dardona, Sameh; Soldner, Nicholas C.; Wheeler, Kevin R.

    2016-03-01

    Faults within electrical connectors are prominent in avionics systems due to improper installation, corrosion, aging, and strained harnesses. These faults usually start off as undetectable with existing inspection techniques and increase in magnitude during the component lifetime. Detection and modeling of these faults are significantly more challenging than hard failures such as open and short circuits. Hence, enabling the capability to locate and characterize the precursors of these faults is critical for timely preventive maintenance and mitigation well before hard failures occur. In this paper, an electrical connector model based on a two-level nonlinear least squares approach is proposed. The connector is first characterized as a transmission line, broken into key components such as the pin, socket, and connector halves. Then, the fact that the resonance frequencies of the connector shift as insertion depth changes from a fully inserted to a barely touching contact is exploited. The model precisely captures these shifts by varying only two length parameters. It is demonstrated that the model accurately characterizes a partially inserted connector.

  19. NURSING CARE IN PATIENTS NEONATES WITH PERIPHERALLY INSERTED CENTRAL CATHETER

    Directory of Open Access Journals (Sweden)

    Anacilda Oliveira Vieira

    2013-12-01

    Full Text Available Introduction: The PICC (peripherally inserted central catheter is a long flexible catheter which is inserted through a peripheral vein, progresses through a needle introducer until the final portion of the vena cava, acquiring characteristics of a central catheter. Objective: To point out the main theoretical and scientific ideas that demonstrate the reliability, competence and ability of nurses to perform the PICC. Methodology: Systematic review of articles, which were found by searching the database scientific journals and bibliographies area. Results: The success of integration depends on the patient assessment and choice of venous access where the catheter will be positioned, and its tip should be in the middle third of the superior vena cava, or the middle third of the inferior vena cava. In neonates, which are used more frequently, proper positioning of the catheter is through nursing care in making the dressing, and the first 24 hours it should be compressive. Ideally, the PICC remains in the vein for periods longer than seven days or until the end of treatment, thus decreasing invasive procedures. Conclusion: According to the Federal Board of Nursing (COFEN, it is lawful for the insertion of PICC nurses, provided it has undergone professional training.

  20. [Peripherally inserted central catheter antibiotic therapy for cystic fibrosis patients].

    Science.gov (United States)

    Betegnie, A-L; Cracowski, C; Bedouch, P; Segond, C; Robein-Dobremez, M-J; Pin, I; Allenet, B

    2014-11-01

    Peripherally inserted central catheters (PICC) are more and more used for intravenous antibiotic infusions in cystic fibrosis (CF) patients in the Grenoble area (France). The aim of this study was to assess the use of this technique in this indication. 1. Retrospective evaluation of 102 consecutive PICC insertions over 3years and the incidence of adverse events during the therapy. 2. Prospective evaluation of 12 patient's satisfaction and their nurses over a 3-month period. 3. Comparative analysis of single domiciliary treatment costs using PICC versus peripheral catheter (PC). 102 PICC insertions were attempted in 31 patients. Seven failures and 7 complications occurred during the treatment requiring removal of the PICC, i.e. an overall success rate of 86.2% (88/102). Pain during PICC introduction was 4.2/10 (visual analogical scale). Mean satisfaction levels during therapy were 9.3/10 for patients and 8.7/10 for nurses. Compared with PC, all the patients said that PICC was "more comfortable". Differential costs of treatment with PC and with PICC at home were estimated at 57.15€ and 590.16€ respectively. PICC is an alternative to CP for intravenous antibiotherapy in CF patients, providing better safety and comfort. PICC use should be promoted in this indication. Copyright © 2013 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  1. Insertion of pedagogical activities mediated by ICT in literacy

    Directory of Open Access Journals (Sweden)

    Lúcia Margarete Santos da Costa

    2016-12-01

    Full Text Available This article is cut out of a research dissertation entitled "Educational activities insertion mediated by ICT literacy. This study aimed to implement such activities promoting the integration of ICT as an aid in the literacy process in a primary education school (EF of Santa Maria and had as participants the students of the 3rd year. In this survey we present results of the activities of insertion mediated by E-book technology. Therefore we sought theoretical foundation in authors like Ferreira and Teberoscky (1999, Freire (1989, 1996, Mendonça and Mendonça (2008 and other authors who contribute to the theme. The methodology used was action research that enables the construction of knowledge through practice, reflection-action and intervention in school reality. This study is linked to the line of research "Educational Technologies in Management Network", Federal University of Santa Maria. The results showed that the ICT e-book inserted in literacy contributed significantly to the advancement of learning reading, writing and the development of various skills as well as to build the autonomy of collaboration and cooperation among students considering the teacher as an important articulator and mediator interactions.

  2. Effects of Tools Inserted through Snake-like Surgical Manipulators

    Science.gov (United States)

    Murphy, Ryan J.; Otake, Yoshito; Wolfe, Kevin C.; Taylor, Russell H.; Armand, Mehran

    2015-01-01

    Snake-like manipulators with a large, open lumen can offer improved treatment alternatives for minimally- and less-invasive surgeries. In these procedures, surgeons use the manipulator to introduce and control flexible tools in the surgical environment. This paper describes a predictive algorithm for estimating manipulator configuration given tip position for nonconstant curvature, cable-driven manipulators using energy minimization. During experimental bending of the manipulator with and without a tool inserted in its lumen, images were recorded from an overhead camera in conjunction with actuation cable tension and length. To investigate the accuracy, the estimated manipulator configuration from the model and the ground-truth configuration measured from the image were compared. Additional analysis focused on the response differences for the manipulator with and without a tool inserted through the lumen. Results indicate that the energy minimization model predicts manipulator configuration with an error of 0.24 ± 0.22mm without tools in the lumen and 0.24 ± 0.19mm with tools in the lumen (no significant difference, p = 0.81). Moreover, tools did not introduce noticeable perturbations in the manipulator trajectory; however, there was an increase in requisite force required to reach a configuration. These results support the use of the proposed estimation method for calculating the shape of the manipulator with an tool inserted in its lumen when an accuracy range of at least 1mm is required. PMID:25571571

  3. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  4. Folding and insertion thermodynamics of the transmembrane WALP peptide

    CERN Document Server

    Bereau, Tristan; Pfaendtner, Jim; Deserno, Markus; Karttunen, Mikko

    2015-01-01

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA)$_n$(L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide's insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum---in contrast to both atomistic simulations and the alternative PLUM force field. Even tho...

  5. Comparing Intravenous Insertion Instructional Methods with Haptic Simulators.

    Science.gov (United States)

    McWilliams, Lenora A; Malecha, Ann

    2017-01-01

    Objective. The objective of this review was to compare traditional intravenous (IV) insertion instructional methods with the use of haptic IV simulators. Design. An integrative research design was used to analyze the current literature. Data Sources. A search was conducted using key words intravenous (IV) insertion or cannulation or venipuncture and simulation from 2000 to 2015 in the English language. The databases included Academic Search Complete, CINAHL Complete, Education Resource Information Center, and Medline. Review Methods. Whittemore and Knafl's (2005) strategies were used to critique the articles for themes and similarities. Results. Comparisons of outcomes between traditional IV instructional methods and the use of haptic IV simulators continue to show various results. Positive results indicate that the use of the haptic IV simulator decreases both band constriction and total procedure time. While students are satisfied with practicing on the haptic simulators, they still desire faculty involvement. Conclusion. Combining the haptic IV simulator with practical experience on the IV arm may be the best practice for learning IV insertion. Research employing active learning strategies while using a haptic IV simulator during the learning process may reduce cost and faculty time.

  6. Internal carotid artery rupture caused by carotid shunt insertion.

    Science.gov (United States)

    Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco

    2015-01-01

    Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Comparing Intravenous Insertion Instructional Methods with Haptic Simulators

    Science.gov (United States)

    Malecha, Ann

    2017-01-01

    Objective. The objective of this review was to compare traditional intravenous (IV) insertion instructional methods with the use of haptic IV simulators. Design. An integrative research design was used to analyze the current literature. Data Sources. A search was conducted using key words intravenous (IV) insertion or cannulation or venipuncture and simulation from 2000 to 2015 in the English language. The databases included Academic Search Complete, CINAHL Complete, Education Resource Information Center, and Medline. Review Methods. Whittemore and Knafl's (2005) strategies were used to critique the articles for themes and similarities. Results. Comparisons of outcomes between traditional IV instructional methods and the use of haptic IV simulators continue to show various results. Positive results indicate that the use of the haptic IV simulator decreases both band constriction and total procedure time. While students are satisfied with practicing on the haptic simulators, they still desire faculty involvement. Conclusion. Combining the haptic IV simulator with practical experience on the IV arm may be the best practice for learning IV insertion. Research employing active learning strategies while using a haptic IV simulator during the learning process may reduce cost and faculty time.

  8. Pneumothorax as a complication of central venous catheter insertion.

    Science.gov (United States)

    Tsotsolis, Nikolaos; Tsirgogianni, Katerina; Kioumis, Ioannis; Pitsiou, Georgia; Baka, Sofia; Papaiwannou, Antonis; Karavergou, Anastasia; Rapti, Aggeliki; Trakada, Georgia; Katsikogiannis, Nikolaos; Tsakiridis, Kosmas; Karapantzos, Ilias; Karapantzou, Chrysanthi; Barbetakis, Nikos; Zissimopoulos, Athanasios; Kuhajda, Ivan; Andjelkovic, Dejan; Zarogoulidis, Konstantinos; Zarogoulidis, Paul

    2015-03-01

    The central venous catheter (CVC) is a catheter placed into a large vein in the neck [internal jugular vein (IJV)], chest (subclavian vein or axillary vein) or groin (femoral vein). There are several situations that require the insertion of a CVC mainly to administer medications or fluids, obtain blood tests (specifically the "central venous oxygen saturation"), and measure central venous pressure. CVC usually remain in place for a longer period of time than other venous access devices. There are situations according to the drug administration or length of stay of the catheter that specific systems are indicated such as; a Hickman line, a peripherally inserted central catheter (PICC) line or a Port-a-Cath may be considered because of their smaller infection risk. Sterile technique is highly important here, as a line may serve as a port of entry for pathogenic organisms, and the line itself may become infected with organisms such as Staphylococcus aureus and coagulase-negative Staphylococci. In the current review we will present the complication of pneumothorax after CVC insertion.

  9. A RETROSPECTIVE STUDY ON ACCEPTABILITY AND COMPLICATIONS OF PPIUCD INSERTION

    Directory of Open Access Journals (Sweden)

    Runjun

    2016-04-01

    Full Text Available BACKGROUND Purpose: To study the acceptance level of Post-Partum Intrauterine Contraceptive Device (PPIUCD insertion among women attending tertiary level hospital for delivery between January 2013 to July 2015 in relation to age, parity and mode of delivery, safety and their complaints/complications during followup visit. METHOD This is a retrospective study done in a tertiary care centre, Jorhat Medical College and Hospital, Assam, between January 2013 to July 2015. Women who had accepted PPIUCD after delivery (Vaginally or by Lower Segment Caesarean section were included in this study. The entire PPIUCD inserted patients were followed up to 6 weeks and 6 months after delivery. With the help of data collected, relevant parameters and data are critically analysed in our study. RESULTS Acceptance of PPIUCD showed an increasing trend, acceptance was more among patients undergoing caesarean section; 43.86% of the acceptors were in the age group of 21-25 years. More than 50% of the total acceptors in the study came for followup. The main complaints at followup were missing thread and bleeding. The main causes of removal were bleeding and pressure from family. CONCLUSION The acceptance of PPIUCD was high in this study. The PPIUCD was demonstrably safe having no serious complication reported after insertion or during followup and low rates of expulsion. The method may be particularly beneficial in our setting where women do not come for postnatal contraception counselling and usage.

  10. Risk factors for development of complication following peripherally inserted central

    Directory of Open Access Journals (Sweden)

    Hakan Aydın

    2014-03-01

    Full Text Available Objectives: Peripherally inserted central venous catheters (PICCs are inserted into central veins through the upper extremity veins. In this retrospective study, we aimed to evaluate PICC procedures, related complications, their causes and factors influencing the success of the procedure during anaesthesia Methods: ‘Central Venous Catheterization Forms’ filled out for 850 patients in whom a PICC was inserted by residents during general anaesthesia between November 2009 and March 2013 in the operating room of Uludag University Medical Faculty Hospital were retrospectively analysed. Results: A total of 1174 procedures were evaluated. The most preferred vein for the first attempt was the right basilic vein (32.7%. Difficulty (more than two attempts with the PICC procedure was correlated with the patient’s age (p30 kg/m² (p<0.05, resident with less than 4 years of training (p=0.001, number of PICC attempts ≥2 (p<0.001, more than one resident involved in the catheterization procedure (p<0.001 and previous failed PICC procedures (p<0.001. Conclusion: We conclude that catheterization should be performed under the surveillance of a staff keeping in mind the risks of complications. In the case of failure following 2 attempts, the procedure should be handed over to a more experienced staff member. J Clin Exp Invest 2014; 5 (1: 29-35

  11. Mechanisms of ovipositor insertion and steering of a parasitic wasp.

    Science.gov (United States)

    Cerkvenik, Uroš; van de Straat, Bram; Gussekloo, Sander W S; van Leeuwen, Johan L

    2017-09-12

    Drilling into solid substrates with slender beam-like structures is a mechanical challenge, but is regularly done by female parasitic wasps. The wasp inserts her ovipositor into solid substrates to deposit eggs in hosts, and even seems capable of steering the ovipositor while drilling. The ovipositor generally consists of three longitudinally connected valves that can slide along each other. Alternative valve movements have been hypothesized to be involved in ovipositor damage avoidance and steering during drilling. However, none of the hypotheses have been tested in vivo. We used 3D and 2D motion analysis to quantify the probing behavior of the fruit-fly parasitoid Diachasmimorpha longicaudata (Braconidae) at the levels of the ovipositor and its individual valves. We show that the wasps can steer and curve their ovipositors in any direction relative to their body axis. In a soft substrate, the ovipositors can be inserted without reciprocal motion of the valves. In a stiff substrate, such motions were always observed. This is in agreement with the damage avoidance hypothesis of insertion, as they presumably limit the overall net pushing force. Steering can be achieved by varying the asymmetry of the distal part of the ovipositor by protracting one valve set with respect to the other. Tip asymmetry is enhanced by curving of ventral elements in the absence of an opposing force, possibly due to pretension. Our findings deepen the knowledge of the functioning and evolution of the ovipositor in hymenopterans and may help to improve man-made steerable probes.

  12. Optimising daytime deliveries when inducing labour using prostaglandin vaginal inserts.

    Science.gov (United States)

    Miller, Hugh; Goetzl, Laura; Wing, Deborah A; Powers, Barbara; Rugarn, Olof

    2016-01-01

    To determine induction start time(s) that would maximise daytime deliveries when using prostaglandin vaginal inserts. Women enrolled into the Phase III trial, EXPEDITE (clinical trial registration: NCT01127581), had labour induced with either a misoprostol or dinoprostone vaginal insert (MVI or DVI). A secondary analysis was conducted to determine the optimal start times for induction by identifying the 12-h period with the highest proportion of deliveries by parity and treatment. Optimal start times for achieving daytime deliveries when using MVI appear to be 19:00 in nulliparae and 23:00 in multiparae. Applying these start times, the median time of onset of active labour would be approximately 08:30 for both parities and the median time of delivery would be the following day at approximately 16:30 for nulliparae and 12:00 (midday) for multiparae. Optimal start times when using DVI appear to be 07:00 for nulliparae and 23:00 for multiparae. Using these start times, the median time of onset of active labour would be the following day at approximately 04:00 and 11:50, and the median time of delivery would be approximately 13:40 and 16:10, respectively. When optimising daytime deliveries, different times to initiate induction of labour may be appropriate depending on parity and the type of retrievable prostaglandin vaginal insert used.

  13. ANATOMICAL VARIATION OF PALMARIS LONGUS: TENDINOUS ORIGIN AND FLESHY INSERTION

    Directory of Open Access Journals (Sweden)

    Buddhadeb Ghosh

    2015-03-01

    Full Text Available A tendinous origin and fleshy insertion of palmaris longus muscle was observed in the left forearm during routine dissection which was performed on adult male cadaver in the department of Anatomy, Dr. Rajendra Prasad Government Medical College. It was having long tendinous origin from the medial epicondyle of the humerus and the surrounding deep fascia. It was fusiform at the lower middle of the forearm. The fleshy muscular insertion was noted to the flexor retinaculum and few muscular fibers interdigitate with flexor carpi ulnaris muscle and palmar aponeurosis. The length of tendon was 19 inches and fleshy muscular length was 11inches. The median nerve and ulnar nerve was covered by this fleshy insertion. This palmaris longus variation is helpful for the surgeon and the radiologist, orthopaedic, plastic surgeon during any diagnosis of the forearm because this fleshy part of muscle can compress the median nerve and ulnar nerve or it can be mistaken as a tumor or ganglion during radiological or clinical examination.

  14. Effects of tools inserted through snake-like surgical manipulators.

    Science.gov (United States)

    Murphy, Ryan J; Otake, Yoshito; Wolfe, Kevin C; Taylor, Russell H; Armand, Mehran

    2014-01-01

    Snake-like manipulators with a large, open lumen can offer improved treatment alternatives for minimally-and less-invasive surgeries. In these procedures, surgeons use the manipulator to introduce and control flexible tools in the surgical environment. This paper describes a predictive algorithm for estimating manipulator configuration given tip position for nonconstant curvature, cable-driven manipulators using energy minimization. During experimental bending of the manipulator with and without a tool inserted in its lumen, images were recorded from an overhead camera in conjunction with actuation cable tension and length. To investigate the accuracy, the estimated manipulator configuration from the model and the ground-truth configuration measured from the image were compared. Additional analysis focused on the response differences for the manipulator with and without a tool inserted through the lumen. Results indicate that the energy minimization model predicts manipulator configuration with an error of 0.24 ± 0.22mm without tools in the lumen and 0.24 ± 0.19mm with tools in the lumen (no significant difference, p = 0.81). Moreover, tools did not introduce noticeable perturbations in the manipulator trajectory; however, there was an increase in requisite force required to reach a configuration. These results support the use of the proposed estimation method for calculating the shape of the manipulator with an tool inserted in its lumen when an accuracy range of at least 1mm is required.

  15. Numerical simulation of the insertion process of an uncemented hip prosthesis in order to evaluate the influence of residual stress and contact distribution on the stem initial stability.

    Science.gov (United States)

    Monea, Aida Georgeta; Pastrav, Leonard Cezar; Mulier, Michiel; Van der Perre, Georges; Jaecques, Siegfried V

    2014-01-01

    The long-term success of a cementless total hip arthroplasty depends on the implant geometry and interface bonding characteristics (fit, coating and ingrowth) and on stem stiffness. This study evaluates the influence of stem geometry and fitting conditions on the evolution and distribution of the bone-stem contact, stress and strain during and after the hip stem insertion, by means of dynamic finite element techniques. Next, the influence of the mechanical state (bone-stem contact, stress and strain) resulted from the insertion process on the stem initial resistance to subsidence is investigated. In addition, a study on the influence of bone-stem interface conditions (friction) on the insertion process and on the initial stem stability under physiological loading is performed. The results indicate that for a stem with tapered shape the contact in the proximal part of the stem was improved, but contact in the calcar region was achieved only when extra press-fit conditions were considered. Changes in stem geometry towards a more tapered shape and extra press fit and variation in the bone-stem interface conditions (contact amount and high friction) led to a raise in the total insertion force. A direct positive relationship was found between the stem resistance to subsidence and stem geometry (tapering and press fit), bone-stem interface conditions (bone-stem contact and friction interface) and the mechanical status at the end of the insertion (residual stress and strain). Therefore, further studies on evaluating the initial performance of different stem types should consider the parameters describing the bone-stem interface conditions and the mechanical state resulted from the insertion process.

  16. Role of the import motor in insertion of transmembrane segments by the mitochondrial TIM23 complex.

    Science.gov (United States)

    Popov-Čeleketić, Dušan; Waegemann, Karin; Mapa, Koyeli; Neupert, Walter; Mokranjac, Dejana

    2011-06-01

    The TIM23 complex mediates translocation of proteins across, and their lateral insertion into, the mitochondrial inner membrane. Translocation of proteins requires both the membrane-embedded core of the complex and its ATP-dependent import motor. Insertion of some proteins, however, occurs in the absence of ATP, questioning the need for the import motor during lateral insertion. We show here that the import motor associates with laterally inserted proteins even when its ATPase activity is not required. Furthermore, our results suggest a role for the import motor in lateral insertion. Thus, the import motor is involved in ATP-dependent translocation and ATP-independent lateral insertion.

  17. Ease of insertion of the laryngeal mask airway in pediatric surgical patients: Predictors of failure and outcome.

    Science.gov (United States)

    Asida, S M; Ahmed, S S

    2016-01-01

    Laryngeal mask airway (LMA) is an useful alternative to endotracheal tube for airway management. The risk of life-threatening adverse respiratory events during its use is rare, but we need to know about the risk-adjusted prediction of its insertion failure requiring rescue tracheal intubation and its impact on patient outcome. Five hundred patients; 6 months to 12-year-old, American Society of Anesthesiologists I and II scheduled to undergo elective surgical procedures that require general anesthesia were included in this study. LMA was inserted after induction of anesthesia. The insertion conditions, intra, and postoperative events were recorded. Our primary outcome variable was trial success from the first time. We recorded 426 cases (85.2%) of first trial success with clear airway compared to 46 case (9.2%) of second trial success (P ≤ 0.001). Predictors of failure of first attempt of LMA insertion include abnormal airway anatomy (91%), body weight Predictors of LMA failure in the pediatric surgical population should be independently considered. The study is registered in the Australian and New Zealand clinical trial registry with the allocated trial number: ACTRN12614000994684. Web address of trial: http://www.ANZCTR.org.au/A CTRN12614000994684.aspx.

  18. Silver(i)-promoted insertion into X-H (X = Si, Sn, and Ge) bonds with N-nosylhydrazones.

    Science.gov (United States)

    Liu, Zhaohong; Li, Qiangqiang; Yang, Yang; Bi, Xihe

    2017-02-21

    Silver(i)-promoted carbene insertion into X-H (X = Si, Sn, and Ge) bonds has been realized by using unstable diazo compounds, which are generated in situ from N-nosylhydrazones as carbene precursors. The reaction tolerates a wide range of functional groups and delivers a number of valuable silicon-containing compounds in very high yields (up to 96%). Moreover, organostannanes and organogermanes were as well effectively obtained in very good yields under optimal conditions.

  19. Lithium Insertion in Poly (ethylene oxide)/MoO3 Xerogel Nanocomposite Films

    Institute of Scientific and Technical Information of China (English)

    HU Yong-sheng; CHEN Wen; XU Qing; YUAN Run-zhang

    2002-01-01

    The nanocomposite films were prepared by direct intercalation of poly ( ethylene oxide ) and PEO into MoO3 xerogel via sol-gel route. The electrochromic behavior and the chemical conditions of Li + ions were investigated by cyclic voltammograms, UV-visible spectral transmittance and XPS. The results show that the cycling efficiency and the reversibility of insertion/extraction of Li+ ins in (PEO)1MoO3·nH2O nanocomposite film were improved. The intercalation of PEO into MoO3 xerogel modulated the wavelength range of electrochromism and enhanced the electrochromic efficiency. Two different chemical conditions of Li + ions existing in the interlayer and interstitial positions of MoO3 lattice were observed in MoO3 xerogel and (PEO)1 MoO3·nH2O nanocomposite films.

  20. Insertion of operation-and-indicate instructions for optimized SIMD code

    Science.gov (United States)

    Eichenberger, Alexander E; Gara, Alan; Gschwind, Michael K

    2013-06-04

    Mechanisms are provided for inserting indicated instructions for tracking and indicating exceptions in the execution of vectorized code. A portion of first code is received for compilation. The portion of first code is analyzed to identify non-speculative instructions performing designated non-speculative operations in the first code that are candidates for replacement by replacement operation-and-indicate instructions that perform the designated non-speculative operations and further perform an indication operation for indicating any exception conditions corresponding to special exception values present in vector register inputs to the replacement operation-and-indicate instructions. The replacement is performed and second code is generated based on the replacement of the at least one non-speculative instruction. The data processing system executing the compiled code is configured to store special exception values in vector output registers, in response to a speculative instruction generating an exception condition, without initiating exception handling.

  1. Palladium(II)-catalyzed intramolecular carboxypalladation-olefin insertion cascade: direct access to indeno[1,2-b]furan-2-ones.

    Science.gov (United States)

    Vinoth, Perumal; Vivekanand, Thavaraj; Suryavanshi, Padmakar A; Menéndez, J Carlos; Sasai, Hiroaki; Sridharan, Vellaisamy

    2015-05-14

    A catalytic, atom-economical, domino 5-endo-dig cyclization-intramolecular olefin insertion sequence was developed under mild conditions. Aryl alkynoic acids bearing a tethered enone partner afforded the indeno[1,2-b]furan-2-ones, the core skeleton present in a number of biologically significant molecules including the natural product solanacol, under ligand-free, palladium-catalyzed reaction conditions in high yields. The competitive β-hydride elimination in the final step leading to the conjugated analogs was avoided by the addition of lithium bromide. A plausible mechanism for this domino sequence is proposed involving intramolecular carboxypalladation and olefin insertion steps.

  2. Ultrasound-guided central line insertion and standard peripherally inserted catheter placement in preterm infants: Comparing results from prospective study in a single-center

    Directory of Open Access Journals (Sweden)

    Dany Antanios Al Hamod

    2016-01-01

    Full Text Available Background: Among preterm infants, the peripherally inserted central catheter (PICC is the standard line for central venous access; however, its placement exposes them to hypothermia and pain. Ultrasound (US-guided central line insertion may be less morbid than standard PICC line. Aims: To determine the ease, success rate, and morbidity associated with US-guided central line insertion in the internal jugular vein (IJV by comparing it to the standard PICC line placement. Materials and Methods: This is a single-center nonrandomized prospective study evaluating preterm infants between October 2013 and June 2014. Patients were allocated into two groups: The standard group (control group who underwent blind PICC line insertion and the intervention group who underwent a percutaneous US-guided central line insertion in the IJV. The epicutaneo-cava-catheter was used in both groups. Results: Fifty neonates were enrolled on study. A statistically difference in favor of US-IJV insertion was noted concerning the rate of successful first attempt (P < 0.001, insertion (P = 0.001, and procedure duration (P < 0.001 and number of trials (P < 0.001 compared to PICC. No difference in complications (P = 1.000 was noted. Conclusion: US guided catheterization of the IJV technique is faster than PICC line insertion with higher rates of successful first attempt and insertion, less procedure duration and fewer number of trials compared to PICC line insertion. There were no differences in complications.

  3. Isolation of acetate auxotrophs of the methane-producing archaeon Methanococcus maripaludis by random insertional mutagenesis.

    Science.gov (United States)

    Kim, W; Whitman, W B

    1999-01-01

    To learn more about autotrophic growth of methanococci, we isolated nine conditional mutants of Methanococcus maripaludis after transformation of the wild type with a random library in pMEB.2, a suicide plasmid bearing the puromycin-resistance cassette pac. These mutants grew poorly in mineral medium and required acetate or complex organic supplements such as yeast extract for normal growth. One mutant, JJ104, was a leaky acetate auxotroph. A plasmid, pWDK104, was recovered from this mutant by electroporation of a plasmid preparation into Escherichia coli. Transformation of wild-type M. maripaludis with pWDK104 produced JJ104-1, a mutant with the same phenotype as JJ104, thus establishing that insertion of pWDK104 into the genome was responsible for the phenotype. pWDK104 contained portions of the methanococcal genes encoding an ABC transporter closely related to MJ1367-MJ1368 of M. jannaschii. Because high levels of molybdate, tungstate, and selenite restored growth to wild-type levels, this transporter may be specific for these oxyanions. A second acetate auxotroph, JJ117, had an absolute growth requirement for either acetate or cobalamin, and wild-type growth was observed only in the presence of both. Cobinamide, 5', 6'-dimethylbenzimidazole, and 2-aminopropanol did not replace cobalamin. This phenotype was correlated with tandem insertions in the genome but not single insertions and appeared to have resulted from an indirect effect on cobamide metabolism. Plasmids rescued from other mutants contained portions of ORFs denoted in M. jannaschii as endoglucanase (MJ0555), transketolase (MJ0681), thiamine biosynthetic protein thiI (MJ0931), and several hypothetical proteins (MJ1031, MJ0835, and MJ0835.1). PMID:10430573

  4. Maxillary reconstruction to enable implant insertion: a retrospective study of 181 patients

    Directory of Open Access Journals (Sweden)

    Carneiro José Mario

    2008-12-01

    Full Text Available Abstract Background The purpose of the present study was to evaluate different types of maxillary pre-prosthetic surgery using autogenous bone graft and suggest a guideline for maxillary reconstruction to place implant. Methods 181 patients (125 females and 56 males, age range from 16 to 76 years old, were operated at the Maxillo-Facial Service of the Lille's 2 Universitary Hospital Center (Chairman Pr Joël Ferri. Different techniques were used, but always with autogenous bone grafting. 21 patients underwent a Lefort 1 procedure, 139 underwent sinus graft with or without vestibular onlay graft and 21 underwent onlay graft. This surgical procedure was made to allow the insertion of 685 implants. Results The patients were evaluated by clinical and radiological assessment. In the cases of Lefort 1, the rate of successful osteointegration was higher when the implants were placed in the second part of a two stages procedure: 92%, against 81% for one stage. In cases of sinus lift procedure, the rate of implant success was 98%. The infection rate was 3.5%. There was no significant resorption and the type of prosthesis used was a denture retained by a bar or fixed bridge. In cases of onlay graft, the implant insertion success was 97% and there was no infection. The amount of resorption was more significant in the pre-maxilla than in the other areas and the type of prosthesis used was fixed dentures. Conclusion These observations demonstrate that: the aetiology of the bone defect indicate the type and number of the surgical procedures to re-established good jaws relationship and give the bone conditions to implant insertion successful. Clinical Relevance A guideline for surgical decision in the maxillary reconstruction for oral rehabilitation by implants may help to prevent failures of osseous resorption disorders and to foresee the investment of the bone in quality and necessary quantity.

  5. Overlap Between Anterior Cruciate Ligament and Anterolateral Meniscal Root Insertions: A Scanning Electron Microscopy Study.

    Science.gov (United States)

    Steineman, Brett D; Moulton, Samuel G; Haut Donahue, Tammy L; Fontboté, Cristián A; LaPrade, Christopher M; Cram, Tyler R; Dean, Chase S; LaPrade, Robert F

    2017-02-01

    The anterolateral meniscal root (ALMR) has been reported to intricately insert underneath the tibial insertion of the anterior cruciate ligament (ACL). Previous studies have begun to evaluate the relationship between the insertion areas and the risk of iatrogenic injuries; however, the overlap of the insertions has yet to be quantified in the sagittal and coronal planes. To investigate the insertions of the human tibial ACL and ALMR using scanning electron microscopy (SEM) and to quantify the overlap of the ALMR insertion in the coronal and sagittal planes. Descriptive laboratory study. Ten cadaveric knees were dissected to isolate the tibial ACL and ALMR insertions. Specimens were prepared and imaged in the coronal and sagittal planes. After imaging, fiber directions were examined to identify the insertions and used to calculate the percentage of the ACL that overlaps with the ALMR instead of inserting into bone. Four-phase insertion fibers of the tibial ACL were identified directly medial to the ALMR insertion as they attached onto the tibial plateau. The mean percentage of ACL fibers overlapping the ALMR insertion instead of inserting into subchondral bone in the coronal and sagittal planes was 41.0% ± 8.9% and 53.9% ± 4.3%, respectively. The percentage of insertion overlap in the sagittal plane was significantly higher than in the coronal plane ( P = .02). This study is the first to quantify the ACL insertion overlap of the ALMR insertion in the coronal and sagittal planes, which supplements previous literature on the insertion area overlap and iatrogenic injuries of the ALMR insertion. Future studies should determine how much damage to the ALMR insertion is acceptable to properly restore ACL function without increasing the risk for tears of the ALMR. Overlap of the insertion areas on the tibial plateau has been previously reported; however, the results of this study demonstrate significant overlap of the insertions superior to the insertion sites on the

  6. Immediate versus delayed postpartum insertion of contraceptive implant for contraception.

    Science.gov (United States)

    Sothornwit, Jen; Werawatakul, Yuthapong; Kaewrudee, Srinaree; Lumbiganon, Pisake; Laopaiboon, Malinee

    2017-04-22

    The spacing of pregnancies has a positive impact on maternal and newborn health. The progestin contraceptive implant, which is a long-acting, reversible method of contraception, has a well-established low failure rate that is compatible with tubal sterilization. The standard provision of contraceptive methods on the first postpartum visit may put some women at risk of unintended pregnancy, either due to loss to follow-up or having sexual intercourse prior to receiving contraception. Therefore, the immediate administration of contraception prior to discharge from the hospital that has high efficacy may improve contraceptive prevalence and prevent unintended pregnancy. To compare the initiation rate, effectiveness, and side effects of immediate versus delayed postpartum insertion of implant for contraception. We searched for eligible studies up to 28 October 2016 in the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, and POPLINE. We examined review articles and contacted investigators. We also checked registers of ongoing clinical trials, citation lists of included studies, key textbooks, grey literature, and previous systematic reviews for potentially relevant studies. We sought randomised controlled trials (RCTs) that compared immediate postpartum versus delayed insertion of contraceptive implant for contraception. Two review authors (JS, YW) independently screened titles and abstracts of the search results, and assessed the full-text articles of potentially relevant studies for inclusion. They extracted data from the included studies, assessed risk of bias, compared results, and resolved disagreements by consulting a third review author (PL or SK). We contacted investigators for additional data, where possible. We computed the Mantel-Haenszel risk ratio (RR) with 95% confidence interval (CI) for binary outcomes and the mean difference (MD) with 95% CI for continuous variables. Three studies that included 410 participants met the

  7. Lithium Insertion in LixMn2O4, 0

    DEFF Research Database (Denmark)

    West, Keld; Zachau-Christiansen, Birgit; Skaarup, Steen

    1996-01-01

    The electrochemical lithium insertion properties of highly crystalline LixMn2O4 are investigated in the approximate lithium insertion range 0 ... of the lithium insertion/extraction reactions is better at the higher voltages (versus Li/Li+), and particularly at the 4 V plateau. The lithium insertion/extraction reaction at the 1 V plateau although essentially reversible is associated with a significant voltage hysteresis....

  8. Micropore closure kinetics are delayed following microneedle insertion in elderly subjects.

    Science.gov (United States)

    Kelchen, Megan N; Siefers, Kyle J; Converse, Courtney C; Farley, Matthew J; Holdren, Grant O; Brogden, Nicole K

    2016-03-10

    Transdermal delivery is an advantageous method of drug administration, particularly for an elderly population. Microneedles (MNs) allow transdermal delivery of otherwise skin-impermeable drugs by creating transient micropores that bypass the barrier function of the skin. The response of aging skin to MNs has not been explored, and we report for the first time that micropore closure is delayed in elderly subjects in a manner that is dependent upon MN length, number, and occlusion of the micropores. Twelve control subjects (25.6±2.8years) and 16 elderly subjects (77.3±6.8years) completed the study. Subjects were treated with MNs of 500μm or 750μm length, in arrays containing 10 or 50 MNs. Impedance measurements made at baseline, post-MN insertion, and at predetermined time points demonstrated that restoration of the skin barrier is significantly slower in elderly subjects under both occluded and non-occluded conditions. This was confirmed via calculation of the total permeable area created by the micropores (which would approximate the area available for drug delivery), as well as calculation of the micropore half-life. This pilot study demonstrates that longer timeframes are required to restore the barrier function of aged skin following MN insertion, suggesting that drug delivery windows could be longer following one treatment with a MN array.

  9. Management of fecal incontinence - focus on a vaginal insert for bowel control

    Directory of Open Access Journals (Sweden)

    Sokol ER

    2016-05-01

    Full Text Available Eric R Sokol Department of Obstetrics and Gynecology, Stanford University School of Medicine, Stanford, CA, USA Abstract: Fecal incontinence, also referred to as accidental bowel leakage, is a debilitating condition that impacts quality of life in a significant number of women. Current treatments for fecal incontinence include behavioral modification, biofeedback, drug therapy, and invasive surgical procedures. However, these treatments have suboptimal efficacy due to patient adherence, variability of presentation across patients, cost, and additional health risks. A vaginal bowel control system (EclipseTM System was developed to offer a low-risk, effective, and patient-managed approach to treating accidental bowel leakage. The vaginal bowel control system consists of a vaginal insert and user-controlled, pressure-regulated pump. Once inflated, the balloon of the vaginal insert is directed posteriorly to occlude the rectum, allowing the woman to immediately regain control of bowel function. This article will introduce the design evolution and feasibility studies of the Eclipse System. In addition, this review will discuss the results from a recent clinical trial that demonstrated the safety and efficacy of the vaginal bowel control system in managing fecal incontinence and other symptoms of bowel dysfunction. Keywords: accidental bowel leakage, fecal urgency, vaginal bowel control system, Eclipse System, bowel function

  10. JOINT MOBILIZATION IN THE MANAGEMENT OF PERSISTENT INSERTIONAL ACHILLES TENDINOPATHY: A CASE REPORT.

    Science.gov (United States)

    Jayaseelan, Dhinu J; Post, Andrew A; Mischke, John J; Sault, Josiah D

    2017-02-01

    Insertional Achilles tendinopathy (IAT) can be a challenging condition to manage conservatively. Eccentric exercise is commonly used in the management of chronic tendinopathy; however, it may not be as helpful for insertional tendon problems as compared to mid-portion dysfunction. While current evidence describing the physical therapy management of IAT is developing, gaps still exist in descriptions of best practice. The purpose of this case report is to describe the management of a patient with persistent IAT utilizing impairment-based joint mobilization, self-mobilization, and exercise. A 51-year-old male was seen in physical therapy for complaints of posterior heel pain and reduced running capacity. He was seen by multiple physical therapists previously, but reported continued impairment, and functional restriction. Joint-based non-thrust mobilization and self-mobilization exercise were performed to enhance his ability to run and reduce symptoms. The subject was seen for four visits over the course of two months. He made clinically significant improvements on the Foot and Ankle Activity Measure and Victorian Institute of Sport Assessment-Achilles tendon outcomes, was asymptomatic, and participated in numerous marathons. Improvements were maintained at one-year follow-up. Mobility deficits can contribute to the development of tendinopathy, and without addressing movement restrictions, symptoms and functional decline related to tendinopathy may persist. Joint-directed manual therapy may be a beneficial intervention in a comprehensive plan of care in allowing patients with chronic tendon changes to optimize function. Therapy, Level 4.

  11. Comparison of insertional trauma between suprapatellar and infrapatellar portals for tibial nailing.

    Science.gov (United States)

    Gaines, Robert J; Rockwood, Jason; Garland, Joshua; Ellingson, Christopher; Demaio, Marlene

    2013-09-01

    The purpose of this study was to determine differences in insertional articular trauma in infrapatellar tibial portal and suprapatellar portal intramedullary tibial nail insertion techniques. A cadaveric study was performed on 10 matched pairs of fresh-frozen adult cadaver lower extremities with intact extensor mechanisms. Two study groups with 10 limbs each were created: left lower limbs were treated with a standard medial parapatellar nailing portal and right lower limbs were treated with a suprapatellar tibial nailing portal. Start points were created under fluoroscopic guidance in anteroposterior and mediolateral planes. A start wire was placed and opening reaming was performed on the specimens using instrumentation specific to the nailing portal. Specimens were then dissected by medial parapatellar arthrotomy, revealing the intra-articular condition of the knee structures. The border of the tibial entry reamer hole was measured to the anterior horns of the menisci, anterior cruciate ligament root, and intermeniscal ligament using a digital caliper accurate to 0.02 mm. The structure was considered damaged if the structure was obviously damaged on visual inspection or if a measurement was less than 1 mm. Impact to intra-articular structures was numerically lower in the suprapatellar group (2/10) compared with the infrapatellar group (4/10), but the difference was not statistically significant between the 2 groups (P=.629). The suprapatellar portal approach to the tibial start point demonstrated a lower overall incidence of damage to intra-articular structures, but no significant statistical difference existed between the 2 treatment groups.

  12. Insertion of occupational therapists in the support centers for family health of Fortaleza

    Directory of Open Access Journals (Sweden)

    Fernanda Reis

    2013-08-01

    Full Text Available Today, Family Health Support Centers (FHSC characterize new environment for the activity of occupational therapists in Primary Health Care. Aiming to understand this new insertion we carried out a descriptive study of qualitative nature. Through a focus group, we obtained data on the subject from 13 occupation therapists that have worked in FHSCs in the municipality of Fortaleza, Ceará state, Brazil. The material obtained was categorized by thematic analysis and interpreted based on collective health and occupation therapy frameworks. The results and discussion converged to the categories of (1 Insertion of occupational therapists in the FHSNs studied, and (2 Working conditions: a place characterized by fragilities and overcoming. Our findings point to the need to establish a common agenda between FHSN professionals and Family Health Strategy teams; difficulties in establishing bonds between the supporters and the supported in the work process; working precariousness and material shortage. The encounter of such professionals potentiated reflections about the working processes and the exchange of experiences, raising awareness to new perspectives for occupational therapy in Primary Health Care and to the need to make these professionals’ performances in this specific context more public.

  13. Stabilization of Bio-Oil Fractions for Insertion into Petroleum Refineries

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Robert C. [Iowa State Univ., Ames, IA (United States); Smith, Ryan [Iowa State Univ., Ames, IA (United States); Wright, Mark [Iowa State Univ., Ames, IA (United States); Elliott, Douglas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Resasco, Daniel [Univ. of Oklahoma, Norman, OK (United States); Crossley, Steven [Univ. of Oklahoma, Norman, OK (United States)

    2014-09-28

    This project is part of a collaboration effort between Iowa State University (ISU), University of Oklahoma (OK) and Pacific Northwest National Laboratory (PNNL). The purpose of this project is to stabilize bio-oil fractions and improve their suitability for insertion into petroleum refineries. Bio-oil from fast pyrolysis of biomass is a complex mixture of unstable organic compounds. These organic compounds react under standard room conditions resulting in increases in bio-oil viscosity and water content – both detrimental for bio-oil storage and transportation. This study employed fractionation and upgrading systems to improve the stability of bio-oil. The fractionation system consists of a series of condensers, and electrostatic precipitators designed to separate bio-oil into five fractions: soluble carbohydrates (SF1&2), clean phenolic oligomers (CPO) and middle fraction (SF3&4), light oxygenates (SF5). A two-stage upgrading process was designed to process bio-oil stage fractions into stable products that can be inserted into a refinery. In the upgrading system, heavy and middle bio-oil fractions were upgraded into stable oil via cracking and subsequent hydrodeoxygenation. The light oxygenate fraction was steam reformed to provide a portion of requisite hydrogen for hydroprocessing. Hydrotreating and hydrocracking employed hydrogen from natural gas, fuel gas and light oxygenates reforming. The finished products from this study consist of gasoline- and diesel-blend stock fuels.

  14. Enhancement of Hole Confinement by Monolayer Insertion in Asymmetric Quantum-Barrier UVB Light Emitting Diodes

    KAUST Repository

    Janjua, Bilal

    2014-04-01

    We study the enhanced hole confinement by having a large bandgap AlGaN monolayer insertion (MLI) between the quantum well (QW) and the quantum barrier (QB). The numerical analysis examines the energy band alignment diagrams, using a self-consistent 6 × 6 k ·p method and, considering carrier distribution, recombination rates (Shockley-Reed-Hall, Auger, and radiative recombination rates), under equilibrium and forward bias conditions. The active region is based on AlaGa1-aN (barrier)/AlbGa1-bN (MLI)/AlcGa1-cN (well)/AldGa1-dN (barrier), where b > d > a > c. A large bandgap AlbGa1-bN mono layer, inserted between the QW and QB, was found to be effective in providing stronger hole confinement. With the proposed band engineering scheme, an increase of more than 30% in spatial overlap of carrier wavefunction was obtained, with a considerable increase in carrier density and direct radiative recombination rates. The single-QW-based UV-LED was designed to emit at 280 nm, which is an effective wavelength for water disinfection.

  15. The New Layout of the LHC Cleaning Insertions

    CERN Document Server

    Assmann, R W; Brüning, Oliver Sim; Chemli, S; Gasser, D; Jeanneret, J B; Jiménez, J M; Kain, V; Métral, Elias; Peón-Hernández, G; Ramberger, S; Rathjen, C; Risselada, Thys; Ruggiero, F; Vos, L; Kaltchev, D I

    2004-01-01

    The improved LHC collimation system required significant changes in the layout and design of the warm insertions. Requirements for collimation, optics, impedance, vacuum, and additional infrastructure are described and the adopted layout is presented. Various design principles have been explored during the re-design. Magnet positions and collimators were moved significantly, such that a good cleaning efficiency was maintained while impedance was reduced by almost a factor of two. Space for upgrades of the collimation system was reserved (metallic phase 2 collimators would allow for a better efficiency than originally achievable). Scrapers were allocated for beam shaping and diagnostics. The required infrastructure was specified, including a powerful cooling system for the collimators.

  16. ITER CS Model Coil and CS Insert Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Martovetsky, N; Michael, P; Minervina, J; Radovinsky, A; Takayasu, M; Thome, R; Ando, T; Isono, T; Kato, T; Nakajima, H; Nishijima, G; Nunoya, Y; Sugimoto, M; Takahashi, Y; Tsuji, H; Bessette, D; Okuno, K; Ricci, M

    2000-09-07

    The Inner and Outer modules of the Central Solenoid Model Coil (CSMC) were built by US and Japanese home teams in collaboration with European and Russian teams to demonstrate the feasibility of a superconducting Central Solenoid for ITER and other large tokamak reactors. The CSMC mass is about 120 t, OD is about 3.6 m and the stored energy is 640 MJ at 46 kA and peak field of 13 T. Testing of the CSMC and the CS Insert took place at Japan Atomic Energy Research Institute (JAERI) from mid March until mid August 2000. This paper presents the main results of the tests performed.

  17. Calibration aspects of binaural sound reproduction over insert earphones

    DEFF Research Database (Denmark)

    Hoffmann, Pablo F.; Markovic, Milos; Olesen, Søren Krarup

    2012-01-01

    in earphone-based reproduction, binaural reproduction can be applied directly. This paper is concerned with the theoretical and practical aspects relevant to the correct reproduction of binaural signals over insert earphones. To this purpose, a theoretical model originally developed to explain the acoustic......Earphones are nowadays widely adopted for the reproduction of audio material in mobile multimedia and communication platforms, e.g. smartphones. Reproduction of high-quality spatial sound on such platforms can dramatically improve their applicability, and since two channels are always available...

  18. Monoblock versus modular polyethylene insert in uncemented total knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Mikkel Rathsach; Winther, Nikolaj; Lind, Thomas;

    2016-01-01

    Background and purpose - Backside wear of the polyethylene insert in total knee arthroplasty (TKA) can produce clinically significant levels of polyethylene debris, which can lead to loosening of the tibial component. Loosening due to polyethylene debris could theoretically be reduced in tibial...... as maximum total point motion (MTPM)) of the 2 different implant designs. Results - We did not find any statistically significant difference in MTPM between the groups at 3 months (p = 0.2) or at 6 months (p = 0.1), but at 12 and 24 months of follow-up there was a significant difference in MTPM of 0.36 mm (p...

  19. The ATLAS Insertable B-Layer: from construction to operation

    Science.gov (United States)

    La Rosa, A.

    2016-12-01

    The ATLAS Insertable B-Layer (IBL) is the innermost layer of pixel detectors, and was installed in May 2014 at a radius of 3.3 cm from the beam axis, between the existing Pixel detector and a new smaller radius beam-pipe. The new detector, built to cope with high radiation and occupancy, is the first large scale application of 3D sensors and CMOS 130 nm technology. The IBL detector construction was completed within about two years (2012 – 2014), and the key features and challenges met during the IBL project are presented, as well as its commissioning and operational experience at the LHC.

  20. TRACKER INSERTED INTO YB0 & HEAVY LOWERING COMPLETED

    CERN Multimedia

          The Tracker travelled very smoothly from Meyrin to Point 5 during the early hours of December 13th. Lowered later the same day, insertion was completed 18th December. The intense campaign of Tracker connections, involving 980 pipes, 2330 cables and 3623 fibre ribbons, has since begun and is making good progress. The final large element of CMS YE-1 was lowered gently into the cavern on January 22nd. This marks the end of fourteen months of heavy lowering operations.  

  1. The ATLAS Insertable B-Layer: from construction to operation

    CERN Document Server

    La Rosa, Alessandro; The ATLAS collaboration

    2016-01-01

    The ATLAS Insertable B-Layer (IBL) is the innermost layer of pixel detectors, and was installed in May 2014 at a radius of 3.3 cm from the beam axis, between the existing Pixel detector and a new smaller radius beam-pipe. The new detector, built to cope with high radiation and occupancy, is the first large scale application of 3D sensors and CMOS 130 nm technology. The IBL detector construction was completed within about two years (2012-2014), and the key features and challenges met during the IBL project are presented, as well as its commissioning and operational experience at the LHC

  2. Late sensory changes following chest drain insertion during thoracotomy

    DEFF Research Database (Denmark)

    Wildgaard, K; Ringsted, T K; Ravn, J

    2013-01-01

    ) patients, in regard to pain and sensory dysfunction. METHODS: We quantified thermal and pressure thresholds on both the chest drain side and the contralateral side in 11 PTPS patients and 10 pain-free post-thoracotomy patients 33 months after the thoracotomy. On average, each patient had two chest drains...... inserted during surgery. RESULTS: At follow up, two patients experienced pain at the chest drain sites, but had maximal pain near or at the thoracotomy scar. Comparison between chest drain side and control side for all 21 patients demonstrated significantly elevated thresholds for warmth detection and heat...

  3. Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH) program

    Science.gov (United States)

    Fayette, Daniel F.; Speicher, Patricia; Stoklosa, Mark J.; Evans, Jillian V.; Evans, John W.; Gentile, Mike; Pagel, Chuck A.; Hakim, Edward

    1993-01-01

    A joint military-commercial effort to evaluate multichip module (MCM) structures is discussed. The program, Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH), has been designed to identify the failure mechanisms that are possible in MCM structures. The RELTECH test vehicles, technical assessment task, product evaluation plan, reliability modeling task, accelerated and environmental testing, and post-test physical analysis and failure analysis are described. The information obtained through RELTECH can be used to address standardization issues, through development of cost effective qualification and appropriate screening criteria, for inclusion into a commercial specification and the MIL-H-38534 general specification for hybrid microcircuits.

  4. Reverse genetics in Chlamydomonas: a platform for isolating insertional mutants

    Directory of Open Access Journals (Sweden)

    de Montaigu Amaury

    2011-07-01

    Full Text Available Abstract A method was developed to identify insertional mutants of Chlamydomonas reinhardtii disrupted for selected target genes. The approach relies on the generation of thousands of transformants followed by PCR-based screenings that allow for identification of strains harboring the introduced marker gene within specific genes of interest. Our results highlight the strengths and limitations of two independent screens that differed in the nature of the marker DNA used (PCR-amplified fragment containing the plasmid-free marker versus entire linearized plasmid with the marker and in the strategies used to maintain and store transformants.

  5. Calibration aspects of binaural sound reproduction over insert earphones

    DEFF Research Database (Denmark)

    Hoffmann, Pablo F.; Markovic, Milos; Olesen, Søren Krarup

    2012-01-01

    Earphones are nowadays widely adopted for the reproduction of audio material in mobile multimedia and communication platforms, e.g. smartphones. Reproduction of high-quality spatial sound on such platforms can dramatically improve their applicability, and since two channels are always available...... in earphone-based reproduction, binaural reproduction can be applied directly. This paper is concerned with the theoretical and practical aspects relevant to the correct reproduction of binaural signals over insert earphones. To this purpose, a theoretical model originally developed to explain the acoustic...

  6. Flexor Hallucis Longus Tendon Transfer for Calcific Insertional Achilles Tendinopathy.

    Science.gov (United States)

    Howell, Michael A; Catanzariti, Alan R

    2016-01-01

    Calcific insertional Achilles tendinopathy can result in significant pain and disability. Although some patients respond to nonoperative therapy, many patients are at risk for long-term morbidity and unpredictable clinical outcomes. There is no evidence-based data to support the timing of operative invention, choice of procedures, or whether equinus requires treatment. This article suggests the need for a classification system based on physical examination and imaging to help guide treatment. There is an obvious need for evidence-based studies evaluating outcomes and for properly conducted scientific research to establish appropriate treatment protocols. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. A new gap separation mechanism for APS insertion devices.

    Energy Technology Data Exchange (ETDEWEB)

    Trakhtenberg, E. M.; Tcheskidov, V.; Den Hartog, P. K.; Deriy, B.; Erdmann, M.; Makarov, O.; Moog, E. R.

    1999-10-25

    A new gap separation mechanism for use with the standard Advanced Photon Source (APS) 3.3-cm-period undulator magnetic structures has been designed and built and the first system has been installed in the APS storage ring. The system allows a minimum magnetic gap of 10 mm for use with the APS 8-mm insertion device vacuum chambers. The mechanism is a bolted steel frame structure with a simple 4-motor mechanical drive train. The control system uses servomotors with incremental rotary encoders and virtual absolute linear encoders.

  8. Design and implementation of the medium-beta insert of the Fermilab recycler ring

    Energy Technology Data Exchange (ETDEWEB)

    Weishi Wan et al.

    2001-08-15

    The design of the newly installed medium-{beta} insert of the Fermilab Recycler Ring is presented. The design philosophy is outlined. The stringent optical and physical constraints, as well as their influence on the design, are discussed. The impact of the medium-{beta} insert on the Recycler Ring is shown. Engineering design and installation of the new insert is presented.

  9. Insertion Test of the Inner Vacuum Tank inside the Outer Vacuum Tank

    CERN Multimedia

    B. LEVESY

    2002-01-01

    Photos of the insertion test held on 13th of june 2002. The CMS Magnet inner Vacuum Tank is inserted inside the outer vacuum tank. False thermal shield have been placed on the inner vaccum tank to simulated the coil outer thermal shield. This test is a training for the 2 final insertions.

  10. The effect of insertion angle on orthodontic mini-screw torque

    Directory of Open Access Journals (Sweden)

    Seyed Hamid Raji

    2014-01-01

    Full Text Available Background: Primary stability is an important factor for the clinical success of orthodontic mini-screws. The present study made an attempt to evaluate the effect of insertion angle changes on the maximum insertion and removal torque of orthodontic mini-screws. Materials and Methods: In this experimental study, 72 mini-screws (Dual Top Anchor System, Jeil, 1.6 mm diameter, 8 mm length were used. They were randomly divided into four equal groups and inserted in poly-carbonate plates with 3 mm thickness. Then, their maximum insertion torque (MIT and maximum removal torque (MRT were recorded using a digital torque tester/screwdriver. Each group had a different insertion angle (90°, 75°, 60° and 45°. The data were analyzed by SPSS software (version 18 using one-way ANOVA and post-hoc Tukey′s tests. The level of significance was set at 0.05. Results: The maximum MIT was observed in 45° insertion angle (14.84 Ncm and the minimum MIT was reported in 75° insertion angle (12.66 Ncm. The maximum MRT was observed in 45° insertion angle (23.21 Ncm and the minimum MRT was reported in the 90° insertion angle (17.43 Ncm. Conclusion: Oblique insertion of the mini-screws results in higher insertion and removal torques and probably more primary stability compared to the vertical insertion.

  11. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Science.gov (United States)

    2010-04-01

    ... comparing the effectiveness of oral contraceptives to other methods of contraception. (4) A boxed warning... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Patient package inserts for oral contraceptives... Patient package inserts for oral contraceptives. (a) Requirement for a patient package insert. The...

  12. An adverse event of suprapubic catheter SPC insertion. A call for updating the existing guidelines.

    Science.gov (United States)

    Jalil, Rozh; Mukundan, Chandrika; Bhatti, Tahir S

    2012-11-15

    The suprapubic catheter (SPC) is a useful and widely used tool in urological practice. However, complications can arise from its insertion or ongoing care. We add to the literature a case of an adverse event of its insertion where it has gone through a vascular graft and recommending updating the SPC insertion guidelines.

  13. Bonding of SiC and Ti by means of aluminum alloy (6063) insert metal; Aluminium gokin (6063) wo insert zai to shita SiC to Ti no setsugo

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchitori, I. [Hiroshima Industrial Research Institute, Hiroshima (Japan); Kikuchi, Y.; Ozawa, M. [Osaka University, Osaka (Japan). Joining and Welding Research Institute; Haji, A. [Seishin Tetrpack, Co., Kobe (Japan)

    1998-03-20

    The high bonding strength was obtained when SiC ceramic was joined with Titanium under vacuum by using the insert metal of 6063 alloy. The ultimate tensile strength of the bonded specimen of SiC to Ti by 6063 insert alloy showed up to 125 MPa. It was bonded under the conditions of 813K-60 min by diffusion bonding method in vacuum. Pure aluminum was used to as the stress relieving of joint interface. The fractured surfaces between SiC and 6063 alloy was observed and analyzed by SEM-EDX, Mg was enriched on the surface. The enriched regions were near the boundary between 6063 alloy and SiC. Then Oxygen is enriched in any place. It was found by TEM-EDX investigation that the region of the oxide of aluminum existed at the interface. 18 refs., 10 figs., 3 tabs.

  14. ERROR CORRECTION METHOD FOR SEQUENCING DATA WITH INSERTIONS AND DELETIONS

    Directory of Open Access Journals (Sweden)

    A. V. Alexandrov

    2016-01-01

    Full Text Available Subject of Research.A method for error correction for sequencing reads of a haploid organism with insertions and deletions was developed. It was tested on two libraries: a synthesized dataset for Escherichia coli bacterium and a real dataset of reads for Pseudomonas stutzeri. Method. The method is based on using k-mers but only for finding reads that are close to each other. For the close reads a consensus string is created which is then used for correcting errors in the initial reads. Main Results. The algorithm is implemented as a separated program. The program has been tested on both real and synthesized data. The method performance is higher than that of the other known methods (N50 metric was used as well as total contig length and maximal contig length as metrics for comparison. Practical Relevance. The method can be used together with known genome assembly methods not suitable for application with the reads containing insertion and deletion errors.

  15. Investigation on Composite Throat Insert For Cryogenic Engines

    Science.gov (United States)

    Ayyappan, G.; Tiwari, S. B.; Praveen, RS; Mohankumar, L.; Jathaveda, M.; Ganesh, P.

    2017-02-01

    Injector element testing is an important step in the development and qualification of the cryogenic rocket engines. For the purpose of characterising the injectors, sub scale chambers are used. In order to assess the performance of the injectors, different configurations of the injectors are tested using a combustion chamber and a convergent-divergent nozzle. Pressure distribution along the wall of the chamber and throat insert is obtained from the CFD analysis and temperature distribution is obtained from thermal analysis. Thermo-structural analysis is carried out for the sub-scale model of throat inert using temperature dependent material properties. For the experiments a sub-scale model of the thrust chamber is realised. Injector element tests are carried out for the studies. The objective of the present study is to investigate the behaviour of different throat inserts, mainly graphite, 2-D Carbon-Carbon(2D C-C), 4-D Carbon-Carbon (4D C-C) and Silica Phenolic (SP), under pressure and thermal load for repeated operation of the engine. Analytical results are compared with the test results. The paper gives the results of theoretical studies and experiments conducted with all the four type of throat material. It is concluded that 2D C-C is superior in terms of throat erosion being the least under specified combustion environment.

  16. Pyoderma gangrenosum after totally implanted central venous access device insertion

    Directory of Open Access Journals (Sweden)

    Hagen Monica E

    2008-03-01

    Full Text Available Abstract Background Pyoderma gangrenosum is an aseptic skin disease. The ulcerative form of pyoderma gangrenosum is characterized by a rapidly progressing painful irregular and undermined bordered necrotic ulcer. The aetiology of pyoderma gangrenosum remains unclear. In about 70% of cases, it is associated with a systemic disorder, most often inflammatory bowel disease, haematological disease or arthritis. In 25–50% of cases, a triggering factor such as recent surgery or trauma is identified. Treatment consists of local and systemic approaches. Systemic steroids are generally used first. If the lesions are refractory, steroids are combined with other immunosuppressive therapy or to antimicrobial agents. Case presentation A 90 years old patient with myelodysplastic syndrome, seeking regular transfusions required totally implanted central venous access device (Port-a-Cath® insertion. Fever and inflammatory skin reaction at the site of insertion developed on the seventh post-operative day, requiring the device's explanation. A rapid progression of the skin lesions evolved into a circular skin necrosis. Intravenous steroid treatment stopped the necrosis' progression. Conclusion Early diagnosis remains the most important step to the successful treatment of pyoderma gangrenosum.

  17. The ATLAS Insertable B-Layer Pixel Detector

    CERN Document Server

    Pernegger, H; The ATLAS collaboration

    2011-01-01

    ATLAS currently develops a new pixel detector for the first upgrade of its tracking system: The ATLAS Insertable B-Layer Pixel detector (IBL). The new layer will be inserted between the inner most layer of the current pixel detector and a new beam pipe. The sensors are placed at a radius of 3.4 cm. The expected high radiation levels and high hit occupancy require new developments for front-end chip and sensors which can stand radiation levels beyond 5$ imes$10$^{15}$ n$_{eq}$/cm$^{2}$ . ATLAS has developed the new FEI4 chip and new silicon sensors to be used as pixel modules. Furthermore a new lightweight support and cooling structure was developed, which minimizes the overall radiation length and allows detector cooling with CO$_{2}$ at -40 $^{circ}$C coolant temperature. Currently the overall integration and installation procedure is being developed and tested ready for installation in 2013. The paper summarizes the current state of development of IBL modules, first preliminary test results of the new chip ...

  18. Overview of the ATLAS Insertable B-Layer Pixel Detector

    CERN Document Server

    Pernegger, H; The ATLAS collaboration

    2011-01-01

    ATLAS currently develops a new pixel detector for the first upgrade of its tracking system: The ATLAS Insertable B-Layer Pixel detector (IBL). The new layer will be inserted between the inner most layer of the current pixel detector and a new beam pipe. The sensors are placed at a radius of 3.4cm. The expected high radiation levels and high hit occupancy require new developments for front-end chip and the sensor which can stand radiation levels beyond 5E15 neq/cm2. ATLAS has developed the new FEI4 and new silicon sensors to be used as pixel modules. Furthermore a new lightweight support and cooling structure was developed, which minimizes the overall radiation and allows detector cooling with CO2 at -40C coolant temperature. Currently the overall integration and installation procedure is being developed and test ready for installation in ATLAS in 2013. The presentation summarizes the current state of development of IBL modules, first preliminary test results of the new chip with new sensors, the construction ...

  19. Gastrostomy insertion: comparing the options - PEG, RIG or PIG?

    Energy Technology Data Exchange (ETDEWEB)

    Laasch, H.-U. E-mail: hul@smtr.nhs.uk; Wilbraham, L.; Bullen, K.; Marriott, A.; Lawrance, J.A.L.; Johnson, R.J.; Lee, S.H.; England, R.E.; Gamble, G.E.; Martin, D.F

    2003-05-01

    AIM: To compare percutaneous endoscopic gastrostomy (PEG) with radiologically inserted gastrostomy (RIG) and assess a hybrid gastrostomy technique (per-oral image-guided gastrostomy, PIG). MATERIALS AND METHODS: Fifty PEGs and 50 RIGs performed in three centres were prospectively compared and the endoscopic findings of 200 PEGs reviewed. A fluoroscopy-guided technique was modified to place 20 F over-the-wire PEG-tubes in 60 consecutive patients. RESULTS: Technical success was 98%, 100% and 100% for PEG, RIG and PIG, respectively. Antibiotic prophylaxis significantly reduced stoma infection for orally placed tubes (p=0.02). Ten out of 50 (20%) small-bore RIG tubes blocked. Replacement tubes were required in six out of 50 PEGs (12%), 10 out of 50 RIGs (20%), but no PIGs (p<0.001). No procedure-related complications occurred. The function of radiologically placed tubes was significantly improved with the larger PIG (p<0.001), with similar wound infection rates. PIG was successful in 24 patients where endoscopic insertion could not be performed. Significant endoscopic abnormalities were found in 42 out of 200 PEG patients (21%), all related to peptic disease. Insignificant pathology was found in 8.5%. CONCLUSION: PIG combines advantages of both traditional methods with a higher success and lower re-intervention rate. Endoscopy is unlikely to detect clinically relevant pathology other than peptic disease. PIG is a very effective gastrostomy method; it has better long-term results than RIG and is successful where conventional PEG has failed.

  20. Damping insert materials for settling chambers of supersonic wind tunnels

    Science.gov (United States)

    Wu, Jie; Radespiel, Rolf

    2017-03-01

    This study describes the application of a novel damping insert material for reducing the flow fluctuations in a tandem nozzle supersonic wind tunnel. This new damping material is composed of multi-layer stainless steel wired meshes. The influences of the multi-layer mesh, such as the quantity of the mesh layer and the installed location in the settling chamber, to the freestream quality have been investigated. A Pitot probe instrumented with a Kulite pressure sensor and a hot-wire probe are employed to monitor the flow fluctuation in the test section of the wind tunnel. Thereafter, a combined modal analysis is applied for the disturbance qualification. Additionally, the transient Mach number in the test section is measured. The disturbance qualification indicates that the multi-layer mesh performs well in providing reduction of vorticity reduction and acoustic fluctuations. Comparable flow quality of the freestream was also obtained using a combination of flexible damping materials. However, the life-span of the new damping materials is much longer. The time transient of the Mach number measured in the test section indicates that the mean flow is rather constant over run time. Furthermore, the time-averaged pressure along the settling chamber is recorded and it shows the distribution of pressure drop by settling chamber inserts.

  1. Inserting Stress Analysis of Combined Hexagonal Aluminum Honeycombs

    Directory of Open Access Journals (Sweden)

    Xiangcheng Li

    2016-01-01

    Full Text Available Two kinds of hexagonal aluminum honeycombs are tested to study their out-of-plane crushing behavior. In the tests, honeycomb samples, including single hexagonal aluminum honeycomb (SHAH samples and two stack-up combined hexagonal aluminum honeycombs (CHAH samples, are compressed at a fixed quasistatic loading rate. The results show that the inserting process of CHAH can erase the initial peak stress that occurred in SHAH. Meanwhile, energy-absorbing property of combined honeycomb samples is more beneficial than the one of single honeycomb sample with the same thickness if the two types of honeycomb samples are completely crushed. Then, the applicability of the existing theoretical model for single hexagonal honeycomb is discussed, and an area equivalent method is proposed to calculate the crushing stress for nearly regular hexagonal honeycombs. Furthermore, a semiempirical formula is proposed to calculate the inserting plateau stress of two stack-up CHAH, in which structural parameters and mechanics properties of base material are concerned. The results show that the predicted stresses of three kinds of two stack-up combined honeycombs are in good agreement with the experimental data. Based on this study, stress-displacement curve of aluminum honeycombs can be designed in detail, which is very beneficial to optimize the energy-absorbing structures in engineering fields.

  2. Fracture of crystalline silicon nanopillars during electrochemical lithium insertion

    KAUST Repository

    Lee, S. W.

    2012-02-27

    From surface hardening of steels to doping of semiconductors, atom insertion in solids plays an important role in modifying chemical, physical, and electronic properties of materials for a variety of applications. High densities of atomic insertion in a solid can result in dramatic structural transformations and associated changes in mechanical behavior: This is particularly evident during electrochemical cycling of novel battery electrodes, such as alloying anodes, conversion oxides, and sulfur and oxygen cathodes. Silicon, which undergoes 400% volume expansion when alloying with lithium, is an extreme case and represents an excellent model system for study. Here, we show that fracture locations are highly anisotropic for lithiation of crystalline Si nanopillars and that fracture is strongly correlated with previously discovered anisotropic expansion. Contrary to earlier theoretical models based on diffusion-induced stresses where fracture is predicted to occur in the core of the pillars during lithiation, the observed cracks are present only in the amorphous lithiated shell. We also show that the critical fracture size is between about 240 and 360 nm and that it depends on the electrochemical reaction rate.

  3. Spiral family implants inserted in postextraction bone sites.

    Science.gov (United States)

    Danza, Matteo; Guidi, Riccardo; Carinci, Francesco

    2009-06-01

    In the last 2 decades, several investigators have reported immediate placement of dental implants into extraction sockets achieving excellent results with a 2-stage surgical procedure. Recently, immediate loading has become an emerging technique as it has been documented to be a successful and a time saving procedure. As regard, few reports are available for the possibility of immediate/early loading of implants placed in fresh extraction sockets. In addition, they are based on limited series with short follow-up. Thus, we decided to perform a retrospective study on a series of postextractive spiral family implants (SFIs). In the period May 2004 to November 2007, 133 SFIs were inserted in fresh extraction sockets. The mean follow-up was 12 months. Several host-, surgery-, and implant-related factors were investigated and Kaplan-Meier algorithm and Cox regression were used to detect those variables associated with the clinical outcome. Because only 7 of 133 implants were lost (i.e., survival rate, 94.7%) and no statistical differences were detected among the studied variables, no, or reduced, marginal bone loss was considered as an indicator of success rate to evaluate the effect of several host-, surgery-, and implants-related factors. Also, in this case no variable has impact on clinical outcome. It was demonstrated that postextractive SFIs have a high survival and success rate that are similar to those reported in previous studies of 2-stage procedures or in immediate loading implants inserted in healed bone.

  4. Placement peripherally inserted central catheters (PICC): the upper arm approach

    Energy Technology Data Exchange (ETDEWEB)

    Choo, In Wook; Choo, Sung Wook; Choi, Dong Il; Yoon, Jung Hwan; Hwang, Jae Woong; Lim, Jae Hoon [Samsung Medical Center, Seoul (Korea, Republic of); Andrews, James C. [Mayo Clinic, Lansing (United States); Williams, David M.; Cho, Kyung J. [University of Michigan Hospital, Lansing (United States)

    1995-10-15

    To evaluate a recently developed technique to place a medium-duration (weeks to months) central venous access. Within three-year period, 635 patients were referred to interventional radiology suite for placement of peripherally inserted central catheter (PICC). Contrast medium was injected into the peripheral intravenous line and a puncture was made into the opacified vein near the junction of the middle and upper thirds of the upper arm, either the brachial or basilic vein under fluoroscopic guidance. A 5.5-French peel-away sheath was inserted into the vein and a 5-French silicone catheter was introduced with its distal tip to the junction of the right atrium and superior vena cava. Catheter placement was successful in all patients unless there was a central venous obstruction. Catheters were maintained from 2 days to 5 months with a mean of 3 weeks. Complications included infection requiring removal of the PICC in 16 patients (2.5%), acute thrombosis of the subclavian vein in 3 (0.5%). Occluded catheters in 4 patients were easily cleared with urokinase in place. The PICC system is an excellent option for medium-duration central venous access. Patients were able to carry on normal activities with the catheters in place.

  5. End of the EM Barrel Presampler Construction and Insertion

    CERN Multimedia

    Hostachy, J.Y.

    The liquid argon barrel presampler is a thin detector placed in front of the electromagnetic barrel calorimeter, made up of two half barrels also, but with 32 sectors per half barrel instead of 16. Each of these 64 sectors is 3.1 m long, 28 cm large and 2.9 cm thick. Three countries took part in its construction: France (LPSC-Grenoble), Sweden (KTH-Stockholm) and Morocco (Hassan II Ain Chock-Casablanca and Mohamed V-Rabat universities, and CNESTEN-Rabat). The design of the presampler started 11 years ago and the series production began at the end of 2000. Cabling, mechanical and electronic tests of the anodes were achieved in Morocco. Forty-one sectors were assembled and validated at the LPSC-Grenoble and 25 at the KTH-Stockholm. In November 2002, the first half was inserted on the inner face of the first EM calorimeter wheel. The insertion of the other 32 sectors in the second EM calorimeter wheel was achieved in July 2003 (see pictures). The production of two additional sectors will allow us to study the p...

  6. An Incremental High-Utility Mining Algorithm with Transaction Insertion

    Directory of Open Access Journals (Sweden)

    Jerry Chun-Wei Lin

    2015-01-01

    Full Text Available Association-rule mining is commonly used to discover useful and meaningful patterns from a very large database. It only considers the occurrence frequencies of items to reveal the relationships among itemsets. Traditional association-rule mining is, however, not suitable in real-world applications since the purchased items from a customer may have various factors, such as profit or quantity. High-utility mining was designed to solve the limitations of association-rule mining by considering both the quantity and profit measures. Most algorithms of high-utility mining are designed to handle the static database. Fewer researches handle the dynamic high-utility mining with transaction insertion, thus requiring the computations of database rescan and combination explosion of pattern-growth mechanism. In this paper, an efficient incremental algorithm with transaction insertion is designed to reduce computations without candidate generation based on the utility-list structures. The enumeration tree and the relationships between 2-itemsets are also adopted in the proposed algorithm to speed up the computations. Several experiments are conducted to show the performance of the proposed algorithm in terms of runtime, memory consumption, and number of generated patterns.

  7. A minimalist technique for insertion of intrauterine devices

    Directory of Open Access Journals (Sweden)

    Norman David Goldstuck

    2015-05-01

    Full Text Available The world’s population is approaching 7 billion. As a general rule, the countries with the highest population have the least available healthcare resources, the most notable exception being the United States of America (USA. Most of these countries have an urgent need to reduce their populations. The intrauterine device (IUD is used by the largest number of contraceptives world-wide and it has a proven record in reducing unwanted pregnancies. Its efficacy rate as a long-acting reversible contraceptive is matched only by subdermal implants which are not as cost effective. Although the rates of pelvic infection are elevated in many countries with low-resource health care systems, we now know that pelvic infection rates are independent of IUD usage. This is therefore no longer a contraindication for using IUDs on a large scale in family planning programs. The technique of IUD insertion as described in most textbooks and journals is unnecessarily complex and based on ritual rather than good clinical evidence. This is particularly interesting in that at a time where we prefer evidence based medicine there are still so many clinical practice sacred cows. This article advocates a simplification of the technique for inserting IUDs. The scientific rationale for simplifying the technique is presented, as well as evidence that it is as safe if not safer than the currently suggested methods, if used for the correct type of IUD acceptors.

  8. Seamless insertion of real pulmonary nodules in chest CT exams

    Science.gov (United States)

    Pezeshk, Aria; Sahiner, Berkman; Zeng, Rongping; Wunderlich, Adam; Chen, Weijie; Petrick, Nicholas

    2014-03-01

    The availability of large medical image datasets is critical in many applications such as training and testing of computer aided diagnosis (CAD) systems, evaluation of segmentation algorithms, and conducting perceptual studies. However, collection of large repositories of clinical images is hindered by the high cost and difficulties associated with both the accumulation of data and establishment of the ground truth. To address this problem, we are developing an image blending tool that allows users to modify or supplement existing datasets by seamlessly inserting a real lesion extracted from a source image into a different location on a target image. In this study we focus on the application of this tool to pulmonary nodules in chest CT exams. We minimize the impact of user skill on the perceived quality of the blended image by limiting user involvement to two simple steps: the user first draws a casual boundary around the nodule of interest in the source, and then selects the center of desired insertion area in the target. We demonstrate examples of the performance of the proposed system on samples taken from the Lung Image Database Consortium (LIDC) dataset, and compare the noise power spectrum (NPS) of blended nodules versus that of native nodules in simulated phantoms.

  9. Improvement in field uniformity of the hybrid insert magnet

    Energy Technology Data Exchange (ETDEWEB)

    Asano, T; Yoshioka, H; Matsumoto, S; Kiyoshi, T [Tsukuba Magnet Laboratory, National Institute for Materials Science, Sakura 3-13, Tsukuba, Ibaraki 305-0003 (Japan)

    2006-11-15

    The hybrid magnet (HM) at the Tsukuba Magnet Laboratory (TML) generates 35 T in a 52-mm warm bore with a field uniformity of about 6500 ppm in a 10 mm diameter sphere volume (DSV). A new resistive insert magnet with the same bore was designed to provide the higher field uniformity in the HM operation and the construction was started. This e-magnet is composed of three concentric Bitter coils. The height of the outer coil is almost equal to that of present insert, . Tand the middle coil is made of a split-paired winding; . Tthe split gap is 53 mm. The A uniformity better than 10 ppm in a 10 mm DSV will be achieved at a themagnetic field of 34.0 T in a backup field of 14 T. This eimprovement in uniformity, in conjuncllaboration with the improvements of the DC power supply already in progress at the TML, will make it possible to expand the application fields of the HM of the TML.

  10. Mechanics of dynamic needle insertion into a biological material.

    Science.gov (United States)

    Mahvash, Mohsen; Dupont, Pierre E

    2010-04-01

    During needle-based procedures, transitions between tissue layers often lead to rupture events that involve large forces and tissue deformations and produce uncontrollable crack extensions. In this paper, the mechanics of these rupture events is described, and the effect of insertion velocity on needle force, tissue deformation, and needle work is analyzed. Using the J integral method from fracture mechanics, rupture events are modeled as sudden crack extensions that occur when the release rate J of strain energy concentrated at the tip of the crack exceeds the fracture toughness of the material. It is shown that increasing the velocity of needle insertion will reduce the force of the rupture event when it increases the energy release rate. A nonlinear viscoelastic Kelvin model is then used to predict the relationship between the deformation of tissue and the rupture force at different velocities. The model predicts that rupture deformation and work asymptotically approach minimum values as needle velocity increases. Consequently, most of the benefit of using a higher needle velocity can be achieved using a finite velocity that is inversely proportional to the relaxation time of the tissue. Experiments confirm the analytical predictions with multilayered porcine cardiac tissue.

  11. Comparison of three peripherally-inserted central catheters: pilot study.

    Science.gov (United States)

    Di Giacomo, Michele

    Peripherally-inserted central catheters (PICCS) are non-tunnelled, central catheters inserted through a peripheral vein of the arm. They are 50-60 cm long and are usually made of either silicone or second-third generation polyurethane. PICCs can be used for prolonged, continuous or intermittent infusion therapies (up to 3 months) both in hospitalized patients and in patients treated as outpatients, in a hospice, or at home. When establishing a vascular service it is key to select a PICC that meets the requirements of safety, cost-effectiveness, high resistance (ability to take increasing fluid volumes with high pressure devices) and durability, and low complications rate. The complications and dwell times of three different PICCs were studied: coated polyurethane, valved silicone and power-injectable. The study was conducted at the chemotherapy suite at the author's hospital with the aim of selecting the right PICC based on low incidence of complications, resistance and enhanced dwell time. Results show a low incidence of complications and long dwell time among patients with the power-injectable PICC. Furthermore, this study demonstrated a reduction on the rate of occlusion and rupture with power-injectable PICCs, which makes them safer to use for administration of chemotherapy and other vesicant agents, as well as for the management of patients in critical care.

  12. Single gene insertion drives bioalcohol production by a thermophilic archaeon

    Energy Technology Data Exchange (ETDEWEB)

    Basen, M; Schut, GJ; Nguyen, DM; Lipscomb, GL; Benn, RA; Prybol, CJ; Vaccaro, BJ; Poole, FL; Kelly, RM; Adams, MWW

    2014-12-09

    Bioethanol production is achieved by only two metabolic pathways and only at moderate temperatures. Herein a fundamentally different synthetic pathway for bioalcohol production at 70 degrees C was constructed by insertion of the gene for bacterial alcohol dehydrogenase (AdhA) into the archaeon Pyrococcus furiosus. The engineered strain converted glucose to ethanol via acetate and acetaldehyde, catalyzed by the host-encoded aldehyde ferredoxin oxidoreductase (AOR) and heterologously expressed AdhA, in an energy-conserving, redox-balanced pathway. Furthermore, the AOR/AdhA pathway also converted exogenously added aliphatic and aromatic carboxylic acids to the corresponding alcohol using glucose, pyruvate, and/or hydrogen as the source of reductant. By heterologous coexpression of a membrane-bound carbon monoxide dehydrogenase, CO was used as a reductant for converting carboxylic acids to alcohols. Redirecting the fermentative metabolism of P. furiosus through strategic insertion of foreign genes creates unprecedented opportunities for thermophilic bioalcohol production. Moreover, the AOR/AdhA pathway is a potentially game-changing strategy for syngas fermentation, especially in combination with carbon chain elongation pathways.

  13. The ATLAS Insertable B-Layer Detector (IBL)

    CERN Document Server

    Huegging, F; The ATLAS collaboration

    2010-01-01

    The upgrade for the ATLAS detector will undergo different phases towards SLHC. The first upgrade for the Pixel Detector will consist in the construction of a new pixel layer which will be installed during a longer shutdown of the LHC machine, the so-called Phase I Upgrade. The new detector, called Insertable B-Layer (IBL), will be inserted between the existing pixel detector and a new (smaller radius) beam-pipe at a radius of about 3.2 cm. The IBL requires the development of several new technologies to cope with the increase of radiation and pixel occupancy as well as to improve the physics performance of the existing pixel detector. In order to achieve these goals the pixel size is reduced and the material budget is minimized by using new lightweight mechanical support materials and a CO2 based cooling system. Main component of the module development for the IBL is the new ATLAS pixel readout chip, FE-I4, designed in 130 nm technology which features an array of 80 by 336 pixels with a pixel size of 50x250 µ...

  14. In-office insertion of a miniaturized insertable cardiac monitor: Results from the Reveal LINQ In-Office 2 randomized study.

    Science.gov (United States)

    Rogers, John D; Sanders, Prashanthan; Piorkowski, Christopher; Sohail, M Rizwan; Anand, Rishi; Crossen, Karl; Khairallah, Farhat S; Kaplon, Rachelle E; Stromberg, Kurt; Kowal, Robert C

    2017-02-01

    Recent miniaturization of an insertable cardiac monitor (ICM) may make it possible to move device insertion from a hospital to office setting. However, the safety of this strategy is unknown. The primary objective was to compare the safety of inserting the Reveal LINQ ICM in an office vs a hospital environment. Ancillary objectives included summarizing device- and procedure-related adverse events and responses to a physician questionnaire. Five hundred twenty-one patients indicated for an ICM were randomized (1:1 ratio) to undergo ICM insertion in a hospital or office environment at 26 centers in the United States in the Reveal LINQ In-Office 2 study (ClinicalTrials.gov identifier NCT02395536). Patients were followed for 90 days. ICM insertion was successful in all 482 attempted patients (office: 251; hospital: 231). The untoward event rate (composite of unsuccessful insertion and ICM- or insertion-related complications) was 0.8% (2 of 244) in the office and 0.9% (2 of 227) in the hospital (95% confidence interval, -3.0% to 2.9%; 5% noninferiority: P office and 4.4% (10 of 227) of hospital insertions (95% confidence interval [office minus inhospital rates], -5.8% to 1.9%; 5% noninferiority: P office vs a hospital, there were fewer delays >15 minutes (16% vs 35%; P office location "very convenient" more frequently than the hospital location (85% vs 27%; P < .001). The safety profile for the insertion of the Reveal LINQ ICM is excellent irrespective of insertion environment. These results may expand site of service options for LINQ insertion. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  15. Current status of frameless anchored IUD for immediate intracesarean insertion.

    Science.gov (United States)

    Wildemeersch, Dirk; Goldstuck, Norman D; Hasskamp, Thomas

    2016-01-01

    Immediate postpartum intrauterine device (IUD) insertion deserves great attention as it can provide immediate, timely and convenient contraception plus the added benefit of preventing repeat unintended pregnancies. Although women post vaginal delivery can benefit from immediate post-placenta contraception, women undergoing Cesarean section clearly need contraception, as an inter-delivery interval shorter than 18 months places them at a high risk for uterine rupture. The main drawback of currently available framed IUD devices for immediate postpartum insertion of an IUD is their high expulsion and displacement rates when inserted immediately postpartum after both vaginal and Cesarean delivery. Current research suggests that a brief window of opportunity exists of 10 minutes for insertion of conventional IUDs after which time expulsion rates both immediately and over time are greatly enhanced. This paper summarizes the current research conducted to overcome the expulsion problems associated with conventional T-shaped devices as well as through the use of an anchored frameless device. In the 1970s and 1980s, attempts were made to solve the expulsion problem by modifying existing devices, such as adding absorbable sutures (Delta-T) or additional appendages. These attempts proved to be clinically unsuccessful as the catgut suture added to the transverse arms did not provide sufficient resistance to prevent downward displacement and expulsion. An anchoring technique to suspend a copper IUD to the fundus of the uterus was developed in Belgium in the 1980s and has been the subject of extensive ongoing clinical research since 1985. Recently the frameless copper releasing anchor IUD, GyneFix, has been tested for postplacental insertion. Initially, the anchor was modified by the inclusion of a biodegradable cone which was added below the anchoring knot. Clinical studies confirmed the adequacy of this approach suggesting that it was technically possible to anchor an IUD

  16. Research on the Influence of Orthopaedic Inserts on Pressure Distribution in the Foot

    Directory of Open Access Journals (Sweden)

    Ignas Rutulys

    2011-02-01

    Full Text Available The article examines the influence of individual orthopaedic inserts on pressure distribution in the foot. Feet deformations, types of orthopaedic inserts, materials and pressure in the foot testing methods are discussed. Experimental computer measurements of pressure in the foot before and after the use of inserts have been done. During research, the inserts made of different kinds of materials selected according to human weight, pathology, skin sensitivity and many other reasons has been used. It has been determinated that orthopaedic inserts have a more noticeable impact on children whose feet is adjusted easier if compared with those of adults.Article in Lithuanian

  17. One-dimensional Array Grammars and P Systems with Array Insertion and Deletion Rules

    Directory of Open Access Journals (Sweden)

    Rudolf Freund

    2013-09-01

    Full Text Available We consider the (one-dimensional array counterpart of contextual as well as insertion and deletion string grammars and consider the operations of array insertion and deletion in array grammars. First we show that the emptiness problem for P systems with (one-dimensional insertion rules is undecidable. Then we show computational completeness of P systems using (one-dimensional array insertion and deletion rules even of norm one only. The main result of the paper exhibits computational completeness of one-dimensional array grammars using array insertion and deletion rules of norm at most two.

  18. Effects of cutting parameters on tool insert wear in end milling of titanium alloy Ti6Al4V

    Science.gov (United States)

    Luo, Ming; Wang, Jing; Wu, Baohai; Zhang, Dinghua

    2016-06-01

    Titanium alloy is a kind of typical hard-to-cut material due to its low thermal conductivity and high strength at elevated temperatures, this contributes to the fast tool wear in the milling of titanium alloys. The influence of cutting conditions on tool wear has been focused on the turning process, and their influence on tool wear in milling process as well as the influence of tool wear on cutting force coefficients has not been investigated comprehensively. To fully understand the tool wear behavior in milling process with inserts, the influence of cutting parameters on tool wear in the milling of titanium alloys Ti6Al4V by using indexable cutters is investigated. The tool wear rate and trends under different feed per tooth, cutting speed, axial depth of cut and radial depth of cut are analyzed. The results show that the feed rate per tooth and the radial depth of cut have a large influence on tool wear in milling Ti6Al4V with coated insert. To reduce tool wear, cutting parameters for coated inserts under experimental cutting conditions are set as: feed rate per tooth less than 0.07 mm, radial depth of cut less than 1.0 mm, and cutting speed sets between 60 and 150 m/min. Investigation on the relationship between tool wear and cutting force coefficients shows that tangential edge constant increases with tool wear and cutter edge chipping can lead to a great variety of tangential cutting force coefficient. The proposed research provides the basic data for evaluating the machinability of milling Ti6Al4V alloy with coated inserts, and the recommend cutting parameters can be immediately applied in practical production.

  19. Combination of thrombolytic therapy and angioplastic stent insertion in a patient with Budd-Chiari syndrome

    Institute of Scientific and Technical Information of China (English)

    Fatemi Reza; Daryani E Naser; Ganaati Hossein; Zahmatkesh Mehrdad

    2007-01-01

    A 31-year-old female who had well-established polycythemia vera one year before, presented with the sudden onset. She had severe ascites and hepatic encephalopathy 12 d prior to admission. Real-time ultrasonography revealed a supra hepatic thrombosis extending toward the inferior vena cava (IVC).Thrombolytic therapy with systemic streptokinase (250000 IU loading + 100000 IU/h infusion) was started. At the end of 72 h infusion, the patient's general condition improved. A color Doppler ultrasonography then showed complete and partial resolution of the thrombosis in the supra hepatic vein and IVC,respectively. Despite this good response, 12 d later, the symptoms recurred. Venography detected complete obstruction of the IVC. Percutanous balloon angioplasty with stent insertion was performed successfully and the patient was discharged without any evidence of liver disease. A combination of systemic streptokinase and radiological intervention was effective in our patient.

  20. Reduction of insertion loss after annealing of silicon oxynitride optical waveguides

    Institute of Scientific and Technical Information of China (English)

    He De-Yan(贺德衍); K.A.Mc-Greer

    2002-01-01

    The insertion losses of silicon oxynitride (SiON) waveguides have been measured in the 1550 nm wavelength region.The waveguide structure consisted of a 2.0μm SiON waveguide core with a refractive index of 1.50, a 0.5μm SiO2 uppercladding and a 5.0μm SiO2 lower cladding with a refractive index of 1.45. It was found that the wavelength-dependentinsertion losses of the waveguide were greatly reduced by annealing, and the loss was decreased more than 5.7 dB/cm at1550 nm after annealing at optimum conditions. The former was attributed to the reduction of the absorption caused by N-H and Si-H vibration modes, and the latter was due to the improvement of the interface roughness and homogeneity in the waveguides after annealing.

  1. Performance of Silicon carbide whisker reinforced ceramic inserts on Inconel 718 in end milling process

    Science.gov (United States)

    Reddy, M. M.; Joshua, C. X. H.

    2016-03-01

    An experimental investigation is planned in order to study the machinability of Inconel 718 with silicon carbide whisker reinforced ceramic inserts in end milling process. The relationship between the cutting speed, feed rate, and depth of cut against the response factors are studied to show the level of significance of each parameter. The cutting parameters are optimized by using Taguchi method. Implementing analysis of variance, the parameter which influences the surface roughness the most is determined to be the cutting speed, followed by the feed rate and depth of cut. Meanwhile, the optimal cutting condition is determined to have high cutting speed, low feed rate, and high depth of cut in the range of selected parameters.

  2. Respiratory Complications Associated with Insertion of Small-Bore Feeding Tube in Critically Ill Patients

    Directory of Open Access Journals (Sweden)

    Jeong Am Ryu

    2014-05-01

    Full Text Available Small-bore flexible feeding tubes decrease the risk of ulceration of the nose, pharynx, and stomach compared with large-bore and more rigid tubes. However, small-bore feeding tubes have more respiratory system complications, such as pneumothorax, hydropneumothorax, bronchopleural fistula, and pneumonia, which are associated with significant morbidity and mortality. Thus, it is important to confirm the correct position of feeding tubes. Chest X-ray is the gold standard to detect tracheal malpositioning of the feeding tube. We present three cases in which intubated patients exhibited an altered mental state. An assistant guide wire was used at the insertion of small-bore feeding tubes. These conditions are thought to be potential risk factors for tracheobronchial malpositioning of feeding tubes.

  3. Field Quality and Alignment of the Series Produced Superconducting Matching Quadrupoles for the LHC Insertions

    CERN Document Server

    Catalan-Lasheras, Nuria; Kirby, Glyn; Ostojic, Ranko; Perez, Juan C; Prin, Herve

    2005-01-01

    The production of the superconducting quadrupoles for the LHC insertions is advancing well and about half of the magnets have been produced. The coil size and field measurements performed on individual magnets both in warm and cold conditions are yielding significant results. In this paper we present the procedures and results of steering the series production at the magnet manufacturers and the assembly of cold masses at CERN. In particular, we present the correlation between coil sizes and geometrical field errors, the effect of permeability of magnet collars, and the analysis of warm-cold correlations and hysteresis of the main field multipoles. The results are compared with the target values for field multipoles and quadrupole alignment.

  4. Insertion of an electron beam ionizer in a quadrupole spectrometer for secondary neutral mass analysis

    CERN Document Server

    Ameziane, O; Serrano, J; Guzman, B; Aguilar, M A

    2003-01-01

    An insertable electron beam ionizer into a quadrupole-based secondary ion mass spectrometer instrument has been designed and installed to analyze sputtered neutrals. The optimum design conditions of the ionizer have been obtained by modeling various configurations of the system using a simulation program developed by us. The program has allowed us to compute the potentials and ion trajectories inside the system to test the performance of the ion optics design. We have investigated the advantages of using a large ionization volume with low electron current to minimize the space charge effect in the ionizer, as this is the major problem in this type of instrument. In addition, we have used the simulations to obtain' all electrodes voltages which provide an efficient suppression of residual gas and secondary ions. A good useful yield was obtained, even with low electron densities, thanks to the high geometrical acceptance of the ionizer and its large active volume. This configuration implies less thermal radiati...

  5. Comparison of Three Methods for Laryngeal Mask Airway Insertion in Adults: Standard, Lateral and Rotational

    Directory of Open Access Journals (Sweden)

    Ata Mahmoodpoor

    2014-03-01

    Full Text Available Determination of an optimal Laryngeal Mask Airway (LMA insertion technique is of great importance as unsuccessful prolonged insertion and multiple attempts are associated with adverse respiratory effects and trauma. The purpose of this study was to compare the ease of insertion of LMA using the standard approach with lateral and rotational techniques. 150 adult patients undergoing general anesthesia using LMA were randomized into one of the three mentioned techniques: standard, rotational and lateral. The time for LMA insertion, number of LMA insertion attempts and LMA insertion success rate were noted for all patients. Demographic characteristic of patients between three groups did not have significant difference. Patients irritation and time for LMA insertion was significantly less in lateral technique (P

  6. A novel approach to an automated needle insertion in brachytherapy procedures.

    Science.gov (United States)

    Buzurovic, Ivan M; Salinic, Slavisa; Orio, Peter F; Nguyen, Paul L; Cormack, Robert A

    2017-07-15

    One of the most challenging phases in interstitial brachytherapy is the placement of the needles. In these medical procedures, the needles are inserted inside the tissue to guide the positioning of the radioactive sources. The low-dose-rate radioactive sources are placed inside the tissue permanently, whereas a radioactive source in the high-dose-rate brachytherapy is temporarily placed in the desired positions so that the delivery of the prescription dose to the clinical targets can be achieved. Consequently, the precise needle placement directly influences the radiation dose delivery and the treatment outcomes of patients. Any deviation from the desired position of the radioactive sources can cause a suboptimal dose distribution and inadequate tumor coverage. Therefore, it is of significant importance to develop a robust and sophisticated tool that can perform the automatic needle placement with a high level of accuracy for different medical procedures and conditions. In this study, we propose a novel concept for the automatic needle insertion using a new miniature automated robotic system. The mathematical model of this system was presented in detail, allowing the implementation of the model predictive control that can be used to govern the mechanism. The purpose of this approach was to minimize the lateral components of the generalized reactive force which is responsible for the tissue displacement and, consequently, for the needle deflection. The proposed approach was designed to predict and to compensate for the unmeasured disturbances, such as needle deflection or tissue resistance and reactive force, and it was capable of correcting them without waiting until the effect appears at the output of the system causing the needle deviation from the desired positions. The extensive simulation of the system was presented to evaluate the feasibility of the method and the parameters of interest including displacements, system errors and system responses to the change

  7. Supercritical Water Mixture (SCWM) Experiment in the High Temperature Insert-Reflight (HTI-R)

    Science.gov (United States)

    Hicks, Michael C.; Hegde, Uday G.; Garrabos, Yves; Lecoutre, Carole; Zappoli, Bernard

    2013-01-01

    Current research on supercritical water processes on board the International Space Station (ISS) focuses on salt precipitation and transport in a test cell designed for supercritical water. This study, known as the Supercritical Water Mixture Experiment (SCWM) serves as a precursor experiment for developing a better understanding of inorganic salt precipitation and transport during supercritical water oxidation (SCWO) processes for the eventual application of this technology for waste management and resource reclamation in microgravity conditions. During typical SCWO reactions any inorganic salts present in the reactant stream will precipitate and begin to coat reactor surfaces and control mechanisms (e.g., valves) often severely impacting the systems performance. The SCWM experiment employs a Sample Cell Unit (SCU) filled with an aqueous solution of Na2SO4 0.5-w at the critical density and uses a refurbished High Temperature Insert, which was used in an earlier ISS experiment designed to study pure water at near-critical conditions. The insert, designated as the HTI-Reflight (HTI-R) will be deployed in the DECLIC (Device for the Study of Critical Liquids and Crystallization) Facility on the International Space Station (ISS). Objectives of the study include measurement of the shift in critical temperature due to the presence of the inorganic salt, assessment of the predominant mode of precipitation (i.e., heterogeneously on SCU surfaces or homogeneously in the bulk fluid), determination of the salt morphology including size and shapes of particulate clusters, and the determination of the dominant mode of transport of salt particles in the presence of an imposed temperature gradient. Initial results from the ISS experiments will be presented and compared to findings from laboratory experiments on the ground.

  8. Enhanced electrical transparency by ultra-thin LaAlO3 insertion at oxide metal/semiconductor heterointerfaces

    Energy Technology Data Exchange (ETDEWEB)

    Yajima, Takeaki [SLAC National Accelerator Lab., Menlo Park, CA (United States); The Univ. of Tokyo, Tokyo (Japan); Minohara, Makoto [SLAC National Accelerator Lab., Menlo Park, CA (United States); Stanford Univ., Stanford, CA (United States); Bell, Christopher [SLAC National Accelerator Lab., Menlo Park, CA (United States); ; Kumigashira, Hiroshi [Stanford Univ., Stanford, CA (United States); Oshima, Masaharu [The Univ. of Tokyo, Tokyo (Japan); Hwang, Harold Y. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Stanford Univ., Stanford, CA (United States); Hikita, Yasuyuki [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-02-05

    We demonstrate that the electrical conductivity of metal/semiconductor oxide heterojunctions can be increased over 7 orders of magnitude by inserting an ultrathin layer of LaAlO3. This counterintuitive result, that an interfacial barrier can be driven transparent by inserting a wide-gap insulator, arises from the large internal electric field between the two polar LaAlO3 surfaces. In conclusion, this field modifies the effective band offset in the device, highlighting the ability to design the electrostatic boundary conditions with atomic precision.

  9. Conductivity Probe Inserted in Martian Soil, Sol 46

    Science.gov (United States)

    2008-01-01

    This image taken by the Surface Stereo Imager on NASA's Phoenix Mars Lander shows the lander's Thermal and Electrical Conductivity Probe (TECP), at the end of the Robotic Arm, on the 46th Martian day, or sol, of the mission (July 11, 2008). The TECP is inserted at a site called Vestri, which was monitored several times over the course of the mission. The probe's measurements at this site yielded evidence that water was exchanged, daily and seasonally, between the soil and atmosphere. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  10. Collimator design for a multipinhole brain SPECT insert for MRI

    Energy Technology Data Exchange (ETDEWEB)

    Van Audenhaege, Karen; Van Holen, Roel; Vanhove, Christian; Vandenberghe, Stefaan [Department of Electronics and Information Systems, Ghent University-iMinds Medical IT, MEDISIP-IBiTech, De Pintelaan 185 block B/5, Ghent B-9000 (Belgium)

    2015-11-15

    Purpose: Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolution, they have a low soft-tissue contrast, which is an important disadvantage for brain imaging. Magnetic resonance imaging (MRI), on the other hand, has a very high soft-tissue contrast and does not involve extra ionizing radiation. Therefore, the authors designed a brain SPECT insert that can operate inside a clinical MRI. Methods: The authors designed and simulated a compact stationary multipinhole SPECT insert based on digital silicon photomultiplier detector modules, which have shown to be MR-compatible and have an excellent intrinsic resolution (0.5 mm) when combined with a monolithic 2 mm thick LYSO crystal. First, the authors optimized the different parameters of the SPECT system to maximize sensitivity for a given target resolution of 7.2 mm in the center of the field-of-view, given the spatial constraints of the MR system. Second, the authors performed noiseless simulations of two multipinhole configurations to evaluate sampling and reconstructed resolution. Finally, the authors performed Monte Carlo simulations and compared the SPECT insert with a clinical system with ultrahigh-resolution (UHR) fan beam collimators, based on contrast-to-noise ratio and a visual comparison of a Hoffman phantom with a 9 mm cold lesion. Results: The optimization resulted in a stationary multipinhole system with a collimator radius of 150.2 mm and a detector radius of 172.67 mm, which corresponds to four rings of 34 diSPM detector modules. This allows the authors to include eight rings of 24 pinholes, which results in a system volume sensitivity of 395 cps/MBq. Noiseless simulations

  11. Combined heart-kidney transplantation after total artificial heart insertion.

    Science.gov (United States)

    Ruzza, A; Czer, L S C; Ihnken, K A; Sasevich, M; Trento, A; Ramzy, D; Esmailian, F; Moriguchi, J; Kobashigawa, J; Arabia, F

    2015-01-01

    We present the first single-center report of 2 consecutive cases of combined heart and kidney transplantation after insertion of a total artificial heart (TAH). Both patients had advanced heart failure and developed dialysis-dependent renal failure after implantation of the TAH. The 2 patients underwent successful heart and kidney transplantation, with restoration of normal heart and kidney function. On the basis of this limited experience, we consider TAH a safe and feasible option for bridging carefully selected patients with heart and kidney failure to combined heart and kidney transplantation. Recent FDA approval of the Freedom driver may allow outpatient management at substantial cost savings. The TAH, by virtue of its capability of providing pulsatile flow at 6 to 10 L/min, may be the mechanical circulatory support device most likely to recover patients with marginal renal function and advanced heart failure.

  12. Radiation regression patterns after cobalt plaque insertion for retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Buys, R.J.; Abramson, D.H.; Ellsworth, R.M.; Haik, B.

    1983-08-01

    An analysis of 31 eyes of 30 patients who had been treated with cobalt plaques for retinoblastoma disclosed that a type I radiation regression pattern developed in 15 patients; type II, in one patient, and type III, in five patients. Nine patients had a regression pattern characterized by complete destruction of the tumor, the surrounding choroid, and all of the vessels in the area into which the plaque was inserted. This resulting white scar, corresponding to the sclerae only, was classified as a type IV radiation regression pattern. There was no evidence of tumor recurrence in patients with type IV regression patterns, with an average follow-up of 6.5 years, after receiving cobalt plaque therapy. Twenty-nine of these 30 patients had been unsuccessfully treated with at least one other modality (ie, light coagulation, cryotherapy, external beam radiation, or chemotherapy).

  13. The ATLAS Insertable B-Layer: from construction to operation

    CERN Document Server

    La Rosa, Alessandro; The ATLAS collaboration

    2016-01-01

    The ATLAS Insertable B-Layer (IBL) is a fourth layer of pixel detectors, and has been installed in May 2014 at a radius of 3.3 cm between the existing Pixel Detector and a new smaller radius beam-pipe. The new detector, built to cope with high radiation and occupancy, is the first large scale application of 3D detectors and CMOS 130nm technology. The IBL detector construction was achieved within about two years starting from mid-2012 to the May 2014 installation in ATLAS, a very tight schedule to meet the ATLAS installation and detector closure before starting the Run2 in Spring 2015. The key features and challenges met during the IBL project will be presented, as well as its commissioning and operational experience in LHC.

  14. Overview of the ATLAS Insertable B-Layer (IBL) Project

    CERN Document Server

    Djama, F; The ATLAS collaboration

    2012-01-01

    The upgrades for the ATLAS Pixel Detector will be staged in preparation for high luminosity LHC. The first upgrade for the Pixel Detector will be the construction of a new pixel layer which will be installed during the first shutdown of the LHC machine, foreseen in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beampipe at a radius of 3.3 cm. The IBL will require the development of several new technologies to cope with increased radiation and pixel occupancy and also to improve the physics performance through reduction of the pixel size and a more stringent material budget. Two different and promising silicon sensor technologies, planar n-in-n and 3D, are currently under investigation for the IBL. An overview of the IBL project, of the module design and qualification with particular emphasis on irradiation tests will be presented.

  15. Text Steganography using LSB insertion method along with Chaos Theory

    CERN Document Server

    S., Bhavana

    2012-01-01

    The art of information hiding has been around nearly as long as the need for covert communication. Steganography, the concealing of information, arose early on as an extremely useful method for covert information transmission. Steganography is the art of hiding secret message within a larger image or message such that the hidden message or an image is undetectable; this is in contrast to cryptography, where the existence of the message itself is not disguised, but the content is obscure. The goal of a steganographic method is to minimize the visually apparent and statistical differences between the cover data and a steganogram while maximizing the size of the payload. Current digital image steganography presents the challenge of hiding message in a digital image in a way that is robust to image manipulation and attack. This paper explains about how a secret message can be hidden into an image using least significant bit insertion method along with chaos.

  16. The microstructure and micromechanics of the tendon-bone insertion

    Science.gov (United States)

    Rossetti, L.; Kuntz, L. A.; Kunold, E.; Schock, J.; Müller, K. W.; Grabmayr, H.; Stolberg-Stolberg, J.; Pfeiffer, F.; Sieber, S. A.; Burgkart, R.; Bausch, A. R.

    2017-06-01

    The exceptional mechanical properties of the load-bearing connection of tendon to bone rely on an intricate interplay of its biomolecular composition, microstructure and micromechanics. Here we identify that the Achilles tendon-bone insertion is characterized by an interface region of ~500 μm with a distinct fibre organization and biomolecular composition. Within this region, we identify a heterogeneous mechanical response by micromechanical testing coupled with multiscale confocal microscopy. This leads to localized strains that can be larger than the remotely applied strain. The subset of fibres that sustain the majority of loading in the interface area changes with the angle of force application. Proteomic analysis detects enrichment of 22 proteins in the interfacial region that are predominantly involved in cartilage and skeletal development as well as proteoglycan metabolism. The presented mechanisms mark a guideline for further biomimetic strategies to rationally design hard-soft interfaces.

  17. Collimator design for a multipinhole brain SPECT insert for MRI.

    Science.gov (United States)

    Van Audenhaege, Karen; Van Holen, Roel; Vanhove, Christian; Vandenberghe, Stefaan

    2015-11-01

    Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolution, they have a low soft-tissue contrast, which is an important disadvantage for brain imaging. Magnetic resonance imaging (MRI), on the other hand, has a very high soft-tissue contrast and does not involve extra ionizing radiation. Therefore, the authors designed a brain SPECT insert that can operate inside a clinical MRI. The authors designed and simulated a compact stationary multipinhole SPECT insert based on digital silicon photomultiplier detector modules, which have shown to be MR-compatible and have an excellent intrinsic resolution (0.5 mm) when combined with a monolithic 2 mm thick LYSO crystal. First, the authors optimized the different parameters of the SPECT system to maximize sensitivity for a given target resolution of 7.2 mm in the center of the field-of-view, given the spatial constraints of the MR system. Second, the authors performed noiseless simulations of two multipinhole configurations to evaluate sampling and reconstructed resolution. Finally, the authors performed Monte Carlo simulations and compared the SPECT insert with a clinical system with ultrahigh-resolution (UHR) fan beam collimators, based on contrast-to-noise ratio and a visual comparison of a Hoffman phantom with a 9 mm cold lesion. The optimization resulted in a stationary multipinhole system with a collimator radius of 150.2 mm and a detector radius of 172.67 mm, which corresponds to four rings of 34 diSPM detector modules. This allows the authors to include eight rings of 24 pinholes, which results in a system volume sensitivity of 395 cps/MBq. Noiseless simulations show sufficient axial

  18. Overview of the ATLAS Insertable B-Layer (IBL) Project

    CERN Document Server

    Grinstein, S; The ATLAS collaboration

    2012-01-01

    The upgrades for the ATLAS Pixel Detector will be staged in preparation for high luminosity LHC. The first upgrade will be the construction of a new pixel layer which will be installed during the first shutdown of the LHC machine, foreseen in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beam-pipe at a radius of 3.3 cm. The IBL will require the development of several new technologies to cope with increased radiation and pixel occupancy and also to improve the physics performance through reduction of the pixel size and a more stringent material budget. Two silicon sensor technologies, planar and 3D, are currently under investigation for the IBL. An overview of the IBL project, of the module design and the qualification for these sensor technologies will be presented.

  19. Overview of the ATLAS Insertable B-Layer (IBL) Project

    CERN Document Server

    Djama, F; The ATLAS collaboration

    2012-01-01

    The upgrades for the ATLAS Pixel Detector will be staged in preparation for high luminosity LHC. The first upgrade for the Pixel Detector will be the construction of a new pixel layer which will be installed during the first shutdown of the LHC machine, foreseen in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beam-pipe at a radius of 3.3 cm. The IBL will require the development of several new technologies to cope with increased radiation and pixel occupancy and also to improve the physics performance through reduction of the pixel size and a more stringent material budget. Two different and promising silicon sensor technologies, planar n-in-n and 3D, are currently under investigation for the IBL. An overview of the IBL project, of the module design and qualification with particular emphasis on irradiation tests will be presented.

  20. Humanized Care: insertion of obstetric nurses in a teaching hospital.

    Science.gov (United States)

    Medeiros, Renata Marien Knupp; Teixeira, Renata Cristina; Nicolini, Ana Beatriz; Alvares, Aline Spanevello; Corrêa, Áurea Christina de Paula; Martins, Débora Prado

    2016-01-01

    to evaluate the care provided at an Antepartum, Intrapartum, Postpartum (AIP) unit at a teaching hospital following the inclusion of obstetric nurses. transversal study, performed at a AIP unit at a teaching hospital in the capital of the Brazilian state of Mato Grosso. The sample comprised data regarding the 701 childbirths that took place between 2014 and 2016. The data were organized using Excel and analyzed using version 7 of Epi Info software. the results suggest that including obstetric nurses contributed towards qualifying the care provided during labor and childbirth, followed by a reduction in the number of interventions, such as episiotomy caesareans sections, and resulting in encouragement to employ practices that do not interfere in the physiology of the parturition process, which in turn generate good perinatal results. inserting these nurses collaborated towards humanizing obstetric and neonatal care.

  1. Prototype of Superconducting Quadrupole for ISR Low-Beta Insertion

    CERN Multimedia

    1977-01-01

    In colliders, smaller beam cross-section means higher luminosity. Beam-size being proportional to the square-root of the "beta function" value, a small beta means small beam size, hence high luminosity. The first p-p collision in the ISR occurred in January 1971 and in 1973 a study was launched on low-beta insertions, which focus beams to even smaller sizes at the beam crossing points. In 1976 the first prototype of a superconducting quadrupole was tested. Here we see Theodor Tortschanoff with a prototype of 1.25 m magnetic length. Manufacture of 8 quadrupoles (4 of L=1.15 m, 4 of L=0.65 m) began at Alsthom in 1978. They were installed at point 8 of the ISR, enhancing luminosity there until final low-beta operation in December 1983. For details see "Yellow Report" CERN 76-16.

  2. Alu polymorphic insertions reveal genetic structure of north Indian populations.

    Science.gov (United States)

    Tripathi, Manorama; Tripathi, Piyush; Chauhan, Ugam Kumari; Herrera, Rene J; Agrawal, Suraksha

    2008-10-01

    The Indian subcontinent is characterized by the ancestral and cultural diversity of its people. Genetic input from several unique source populations and from the unique social architecture provided by the caste system has shaped the current genetic landscape of India. In the present study 200 individuals each from three upper-caste and four middle-caste Hindu groups and from two Muslim populations in North India were examined for 10 polymorphic Alu insertions (PAIs). The investigated PAIs exhibit high levels of polymorphism and average heterozygosity. Limited interpopulation variance and genetic flow in the present study suggest admixture. The results of this study demonstrate that, contrary to common belief, the caste system has not provided an impermeable barrier to genetic exchange among Indian groups.

  3. [IUD insertion during cesarean section and its most frequent complications].

    Science.gov (United States)

    Alvarez Pelayo, J; Borbolla Sala, M E

    1994-11-01

    A prospective and cooperative study was done in 152 patients that were submitted to cesarean section. Seventy eight patients received intrauterine device (IUD) T CU 220 during cesarean section, and the other 74 patients only got the cesarean section without IUD. The events that were analyzed during the puerperium were pain, bleeding and infection. We didn't find any difference in the results between both groups, these were analyzed with the help of the square chi (X2). These results suggest that with an adequate selection of the patients, the insertion of the IUD during the cesarean section is a secure and helpful method for the fertility control for patients with high risk of reproduction.

  4. Overview of the ATLAS Insertable B-Layer (IBL) Project

    CERN Document Server

    Kagan, M; The ATLAS collaboration

    2013-01-01

    The upgrades for the ATLAS Pixel Detector will be staged in preparation for high luminosity LHC. The first upgrade for the Pixel Detector will be the construction of a new pixel layer which is currently under construction and will be installed during the first shutdown of the LHC machine, in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beam-pipe at a radius of 3.3 cm. The IBL required the development of several new technologies to cope with increased radiation and pixel occupancy and also to improve the physics performance through reduction of the pixel size and a more stringent material budget. Two different silicon sensor technologies, planar n-in-n and 3D, will be used, connected with the new generation 130nm IBM CMOS FE-I4 readout chip via solder bump-bonds. 32 \

  5. Overview and expected Performance of the Insertable B-Layer

    CERN Document Server

    Heim, Timon; The ATLAS collaboration

    2014-01-01

    For Run 2 of the LHC a fourth, innermost Pixel Detector layer on a smaller radius beam pipe has been installed in the ATLAS Detector to add redundancy against radiation damage of the current Pixel Detector and to ensure a high quality tracking and b-tagging performance of the Inner Detector over the coming years until the High Luminosity Upgrade. State of the art components have been produced and assembled onto support structures known as staves over the last two years. In total, 20 staves have been built and qualified in a designated Quality Assurance setup at CERN of which 14 have been integrated onto the beam pipe. Results from the testing are presented and represent the performance of the detector before insertion into the ATLAS Detector.

  6. Assessment of a percutaneous iliosacral screw insertion simulator

    CERN Document Server

    Tonetti, J; Girard, P; Dubois, M; Merloz, P; Troccaz, Jocelyne; 10.1016/j.otsr.2009.07.005

    2009-01-01

    BACKGROUND: Navigational simulator use for specialized training purposes is rather uncommon in orthopaedic and trauma surgery. However, it reveals providing a valuable tool to train orthopaedic surgeons and help them to plan complex surgical procedures. PURPOSE: This work's objective was to assess educational efficiency of a path simulator under fluoroscopic guidance applied to sacroiliac joint percutaneous screw fixation. MATERIALS AND METHODS: We evaluated 23 surgeons' accuracy inserting a guide-wire in a human cadaver experiment, following a pre-established procedure. These medical trainees were defined in three prospective respects: novice or skilled; with or without theoretical knowledge; with or without surgical procedure familiarity. Analysed criteria for each tested surgeon included the number of intraoperative X-rays taken in order to achieve the surgical procedure as well as an iatrogenic index reflecting the surgeon's ability to detect any hazardous trajectory at the time of performing said procedu...

  7. The ATLAS Insertable B-Layer: from construction to operation

    CERN Document Server

    La Rosa, Alessandro

    2016-01-01

    The ATLAS Insertable B-Layer (IBL) is a fourth layer of pixel detectors, and has been installed in May 2014 at a radius of 3.3 cm from the beam axis and between the existing Pixel detector and a new smaller radius beam-pipe. The new detector, built to cope with high radiation and occupancy, is the first large scale application of 3D detectors and CMOS 130 nm technology. The IBL detector construction was achieved within about two years starting from mid-2012 to the May 2014 installation in ATLAS, a very tight schedule to meet the ATLAS installation and detector closure before starting the Run2 in Spring 2015. The key features and challenges met during the IBL project will be presented, as well as its commissioning and operational experience at the LHC.

  8. [Visual functions' detailed evaluating in patients with Sjögren's syndrome before and after intracanalicular implants' (Smart Plug) insertion--(first results)].

    Science.gov (United States)

    Hejcmanová, D; Nemcová, I; Slezák, R

    2006-05-01

    The aim of the study was to determine exact visual functions (log MAR [minimal angle of resolution] and CS [contrast sensitivity]) and to evaluate corneal topographic maps in patients with established (by means of laboratory and biopsy examinations) Sjogren's Syndrome, and to determine the difference in subjective symptoms before and after insertion of the intracanalicular implants as well. Twelve eyes (1 man, 6 women) with established Sjogren's syndrome were examined before and during two months after the insertion of the plugs. The best-corrected visual acuity (BCVA) was assessed on Landolt C rings optotypes. CS was measured on computer-controlled device (Neuroscientific Corp., U.S.A.) in 6 space-frequencies (0.74-29.55 c/deg). The corneal topographic changes (Keraton Opticon) were established by means of comparing total aberrations values before and after the intracanalicular implants' (Smart Plugs type) insertion. The control group for visual functions assessment consisted of 10 woman (20 eyes) of similar middle age. The BCVA on log MAR optotypes was 0.84 (0.69-0.95) before and 0.88 (0.52-1.23) after the insertion, on both occasions, it was lower than in the control group. The CS was before the insertion in all of the spatial frequencies lower, the largest differences were in the frequencies range 1.97-7.29 c/deg (p visual functions in "dry eyes". The measurement of the corneal topography is useful in differential diagnosis and helps to distinguish mild and more serious conditions of dry eye. The improvement of BCVA and CS values after insertion corresponds with patients' subjective evaluating. The best value of the treatment is improvement of the patients' comfort; furthermore, after insertion of the permanent plugs they feel pronounced subjective relief and lowering of the frequency of drops application.

  9. Prevalence, risk factors and outcomes of velamentous and marginal cord insertions: a population-based study of 634,741 pregnancies.

    Directory of Open Access Journals (Sweden)

    Cathrine Ebbing

    Full Text Available OBJECTIVES: To determine the prevalence of, and risk factors for anomalous insertions of the umbilical cord, and the risk for adverse outcomes of these pregnancies. DESIGN: Population-based registry study. SETTING: Medical Birth Registry of Norway 1999-2009. POPULATION: All births (gestational age >16 weeks to <45 weeks in Norway (623,478 singletons and 11,263 pairs of twins. METHODS: Descriptive statistics and odds ratios (ORs for risk factors and adverse outcomes based on logistic regressions adjusted for confounders. MAIN OUTCOME MEASURES: Velamentous or marginal cord insertion. Abruption of the placenta, placenta praevia, pre-eclampsia, preterm birth, operative delivery, low Apgar score, transferral to neonatal intensive care unit (NICU, malformations, birthweight, and perinatal death. RESULTS: The prevalence of abnormal cord insertion was 7.8% (1.5% velamentous, 6.3% marginal in singleton pregnancies and 16.9% (6% velamentous, 10.9% marginal in twins. The two conditions shared risk factors; twin gestation and pregnancies conceived with the aid of assisted reproductive technology were the most important, while bleeding in pregnancy, advanced maternal age, maternal chronic disease, female foetus and previous pregnancy with anomalous cord insertion were other risk factors. Velamentous and marginal insertion was associated with an increased risk of adverse outcomes such as placenta praevia (OR = 3.7, (95% CI = 3.1-4.6, and placental abruption (OR = 2.6, (95% CI = 2.1-3.2. The risk of pre-eclampsia, preterm birth and delivery by acute caesarean was doubled, as was the risk of low Apgar score, transferral to NICU, low birthweight and malformations. For velamentous insertion the risk of perinatal death at term was tripled, OR = 3.3 (95% CI = 2.5-4.3. CONCLUSION: The prevalence of velamentous and marginal insertions of the umbilical cord was 7.8% in singletons and 16.9% in twin gestations, with marginal insertion being more

  10. Insertion torque, resonance frequency, and removal torque analysis of microimplants.

    Science.gov (United States)

    Tseng, Yu-Chuan; Ting, Chun-Chan; Du, Je-Kang; Chen, Chun-Ming; Wu, Ju-Hui; Chen, Hong-Sen

    2016-09-01

    This study aimed to compare the insertion torque (IT), resonance frequency (RF), and removal torque (RT) among three microimplant brands. Thirty microimplants of the three brands were used as follows: Type A (titanium alloy, 1.5-mm × 8-mm), Type B (stainless steel, 1.5-mm × 8-mm), and Type C (titanium alloy, 1.5-mm × 9-mm). A synthetic bone with a 2-mm cortical bone and bone marrow was used. Each microimplant was inserted into the synthetic bone, without predrilling, to a 7 mm depth. The IT, RF, and RT were measured in both vertical and horizontal directions. One-way analysis of variance and Spearman's rank correlation coefficient tests were used for intergroup and intragroup comparisons, respectively. In the vertical test, the ITs of Type C (7.8 Ncm) and Type B (7.5 Ncm) were significantly higher than that of Type A (4.4 Ncm). The RFs of Type C (11.5 kHz) and Type A (10.2 kHz) were significantly higher than that of Type B (7.5 kHz). Type C (7.4 Ncm) and Type B (7.3 Ncm) had significantly higher RTs than did Type A (4.1 Ncm). In the horizontal test, both the ITs and RTs were significantly higher for Type C, compared with Type A. No significant differences were found among the groups, and the study hypothesis was accepted. Type A had the lowest inner/outer diameter ratio and widest apical facing angle, engendering the lowest IT and highest RF values. However, no significant correlations in the IT, RF, and RT were observed among the three groups.

  11. DPEJ placement in cases of PEG insertion failure.

    Science.gov (United States)

    Del Piano, M; Ballarè, M; Carmagnola, S; Orsello, M; Garello, E; Pagliarulo, M; Sartori, M; Montino, F

    2008-02-01

    PEG placement is routinely used for enteral feeding; in some cases PEG is not feasible or indicated due to technical difficulties, such as gastric herniation, organ interposition, or presence of gastroparesis. In these cases, surgical gastrostomy or jejunostomy are possible alternatives; more recently, direct percutaneous jejunostomy (DPEJ) has been proposed to avoid surgical intervention. The aim of the study was to evaluate the necessity, technical feasibility and outcome of DPEJ in a group of patients consecutively proposed for PEG placement. In each patient proposed for PEG placement, an upper gastrointestinal endoscopy was performed, and then a pull traction removal gastrostomy tube (18-20 F) was inserted. When PEG was not feasible or contraindicated, a variable stiffness pediatric videocolonscope was used to reach the jejunum: then DPEJ was performed with the same technique and materials as PEG. In both groups enteral feeding was started 24h after the endoscopic procedure, using an enteral feeding pump and the same nutritional schedules. In a 1-year period 90 patients were proposed for PEG placement; PEG could not be performed for technical reasons in 8 (gastric herniation in 1; organ interposition in 7) and gastroparesis in 1. In one patient both PEG and DPEJ were not feasible for organ interposition. The duration of the endoscopic procedure was slightly longer in DPEJ (mean 20 min versus 15 min). No complications related to the endoscopic procedure were observed in both DPEJ and PEG patients. No nutritional complication were observed in the DPEJ group. In our experience, PEG was not feasible or contraindicated in about 10% of patients proposed for. In these patients, DPEJ was placed: the procedure resulted to be feasible and safe with the use of a pediatric videocolonscope to easily reach the jejunum. The insertion of DPEJ did not change the nutritional management of enteral feeding. However, long-term effects or complications remain to be evaluated in

  12. Insertion device operating experience at the Advanced Photon Source

    Science.gov (United States)

    Grimmer, John; Ramanathan, Mohan; Smith, Martin; Merritt, Michael

    2002-03-01

    The Advanced Photon Source has 29 insertion devices (IDs) installed in the 7 GeV electron storage ring; 28 of these devices, most of which are 3.3 cm period undulators, use two horizontal permanent magnet structures positioned over a straight vacuum chamber. A support and drive mechanism allows the vertical gap between the magnet structures to be varied, thus changing the x-ray energy produced by the ID [J. Viccaro, Proc. SPIE 1345, 28 (1990); E. Gluskin, J. Synchrotron Radiat. 5, 189 (1998)]. Most of these IDs use a drive scheme with two stepper motors, one driving each end through a mechanism synchronizing the upper and lower magnet structures. Our experience in almost 5 yr of operating this system will be discussed. All of the IDs are in continuous operation for approximately 10 weeks at a time. Reliability of operation is of paramount importance, as access to the storage ring for servicing of a single ID inhibits operation for all users. Our experience in achieving highly reliable ID operation is reviewed. Accuracy of operation and repeatability over time are also vital. To this end, these devices use absolute optical linear encoders with submicron resolution for primary position feedback. Absolute rotary encoders are used as a backup to the linear encoders. The benefits and limitations of each type of encoder, and our experience dealing with radiation and electrical noise are reviewed. The insertion devices operate down to gaps as small as 8.5 mm, with clearance over the vacuum chamber as small as 200 μm. The vacuum chamber has a minimum wall thickness of only 1 mm. A number of levels of safeguards are used to prevent contact between the magnet structure and the vacuum chamber. These safeguards and their evolution after gaining operational experience are presented.

  13. A comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery

    Directory of Open Access Journals (Sweden)

    Mohsen Ziyaeifard

    2012-01-01

    Full Text Available Background: The aim of this study was to evaluate intraocular pressure (IOP and hemodynamic responses following insertion of laryngeal mask airway (LMA or endotracheal tube (ETT after anesthesia induction with propofol and remifentanil in cataract surgery. Materials and Methods: In a randomized controlled study, 50 adults scheduled for elective cataract extraction procedure under general anesthesia were allocated to LMA insertion (n = 25 or ETT (n = 25 groups. IOP, systolic blood pressure (SBP, diastolic blood pressure (DBP, and heart rate (HR were measured after insertion of the airway device every minute up to 5 min. Results: There were no significant differences between LMA and ETT groups in SBP, DBP, HR, and IOP immediately after airway instrumentation up to 5 min, except in 4th min in DBP, 2nd min in HR, and 5th min in IOP (7.9 ± 2.3 mmHg in LMA and 9.4 ± 2.5 mmHg in ETT group; P = 0.030. There was good surgeon satisfaction for providing acceptable surgical field in both groups (88% in LMA and 80% in ETT group; P = 0.702. Conclusion: Propofol combined with remifentanil provides good and excellent conditions for insertion of LMA or ETT with minimal hemodynamic disturbances in cataract surgery. Considering LMA insertion is less traumatic than ETT, using LMA may be better than ETT for airway securing in these patients.

  14. Reconstructions of the axial muscle insertions in the occipital region of dinosaurs: evaluations of past hypotheses on marginocephalia and tyrannosauridae using the extant phylogenetic bracket approach.

    Science.gov (United States)

    Tsuihiji, Takanobu

    2010-08-01

    The insertions of the cervical axial musculature on the occiput in marginocephalian and tyrannosaurid dinosaurs have been reconstructed in several studies with a view to their functional implications. Most of the past reconstructions on marginocephalians, however, relied on the anatomy of just one clade of reptiles, Lepidosauria, and lack phylogenetic justification. In this study, these past reconstructions were evaluated using the Extant Phylogenetic Bracket approach based on the anatomy of various extant diapsids. Many muscle insertions reconstructed in this study were substantially different from those in the past studies, demonstrating the importance of phylogenetically justified inferences based on the conditions of Aves and Crocodylia for reconstructing the anatomy of non-avian dinosaurs. The present reconstructions show that axial muscle insertions were generally enlarged in derived marginocephalians, apparently correlated with expansion of their parietosquamosal shelf/frill. Several muscle insertions on the occiput in tyrannosaurids reconstructed in this study using the Extant Phylogenetic Bracket approach were also rather different from recent reconstructions based on the same, phylogenetic and parsimony-based method. Such differences are mainly due to differences in initial identifications of muscle insertion areas or different hypotheses on muscle homologies in extant diapsids. This result emphasizes the importance of accurate and detailed observations on the anatomy of extant animals as the basis for paleobiological inferences such as anatomical reconstructions and functional analyses.

  15. Effect of Insertion Site and Metabolic Load on the Environmental Fitness of a Genetically Modified Pseudomonas fluorescens Isolate

    Science.gov (United States)

    De Leij, Frans A. A. M.; Thomas, Catherine E.; Bailey, Mark J.; Whipps, John M.; Lynch, James M.

    1998-01-01

    An isolate of Pseudomonas fluorescens (SBW25) was modified with different marker genes (lacZY, aph-1, and xylE). These marker genes were inserted singly or in combination into two separate (1 Mbp apart) and presumably nonessential sites (-6- and Ee) on the chromosome of SBW25. This allowed the production of a range of genetically modified SBW25 variants that differed with respect to insertion site of the marker genes and metabolic burden. The environmental fitness of the different SBW25 variants was tested in soil, in the rhizosphere of wheat and pea, and on the phylloplane of wheat. Reduced environmental fitness of the different variants was mainly attributed to the extra metabolic burden of novel gene expression, whereas choice of insertion site was of little significance. Changes in environmental fitness were dependent on the environmental conditions; an environment, such as soil, with a low microbial carrying capacity had a negative effect on the environmental fitness of variants with a large metabolic load. In environments with a larger carrying capacity, such as the rhizosphere of pea, environmental fitness of variants with a large metabolic load was not significantly different from that of variants with a smaller metabolic burden. PMID:9647841

  16. Protein switches identified from diverse insertion libraries created using S1 nuclease digestion of supercoiled-form plasmid DNA.

    Science.gov (United States)

    Tullman, Jennifer; Guntas, Gurkan; Dumont, Matthew; Ostermeier, Marc

    2011-11-01

    We demonstrate that S1 nuclease converts supercoiled plasmid DNA to unit-length, linear dsDNA through the creation of a single, double-stranded break in a plasmid molecule. These double-stranded breaks occur not only in the origin of replication near inverted repeats but also at a wide variety of locations throughout the plasmid. S1 nuclease exhibits this activity under conditions typically employed for the nuclease's single-stranded nuclease activity. Thus, S1 nuclease digestion of plasmid DNA, unlike analogous digestion with DNaseI, effectively halts after the first double-stranded break. This property makes easier the construction of large domain insertion libraries in which the goal is to insert linear DNA at a variety of locations throughout a plasmid. We used this property to create a library in which a circularly permuted TEM1 β-lactamase gene was inserted throughout a plasmid containing the gene encoding Escherichia coli ribose binding protein. Gene fusions that encode allosteric switch proteins in which ribose modulates β-lactamase catalytic activity were isolated from this library using a combination of a genetic selection and a screen.

  17. IUD in first-trimester abortion: immediate intrauterine contraceptive devices insertion vs delayed insertion following the next menstruation bleeding.

    Science.gov (United States)

    Tsikouras, Panagiotis; Vrachnis, Nikolaos; Grapsa, Anastasia; Tsagias, Nikolaos; Pinidis, Petros; Liberis, Anastasios; Ammari, Alexandros; Grapsas, Xenofon; Galazios, Georgios; Liberis, Vasileios

    2014-07-01

    Approximately 21 days after an abortion, ovulation occurs in 50 % of women. Installation of an IUD directly after induced or spontaneous abortion offers immediate contraceptive protection. The purpose of the present study was to weigh up contraceptive safety and adverse reactions of IUD inserted directly after first-trimester abortion under general or paracervical anesthesia as against the fitting of IUD in the days of the next menstrual cycle without anesthesia. During the period May 1987 to October 2010, 73 women (Group A) underwent an immediate post-abortion insertion IUD after a first-trimester spontaneous or induced abortion under general or local paracervical anesthesia and 69 participants (Group B) received IUD during the next menstrual cycle without anesthesia. Questionnaires were completed by all the women of the study with respect to the effects of IUD. The women were examined every 3 months for 1 year after the fitting of the IUD in the out-patient department of the University Obstetrics Gynecological Department of Alexandroupolis, Democritus University of Thrace, Greece. The demographic characteristics of the women of the two groups were similar. The age of the women ranged between 19 and 44 years, while 61.98 % were women with one or two children and 38.02 % were women with three or more children. During the first menstrual cycles, with the exception of vaginal hemorrhages (5 %) and adnexitis (1 %), no serious adverse reactions were noted. During the transvaginal ultrasonography checks in both groups, no observation was made of any dislocation of the IUD, except for two cases in the subgroup of those women with paracervical anesthesia and one case in the women of Group B. As concerns the questionnaire with regard to the women's subjective evaluation of IUD, satisfactory answers were given. There were no differences between the two groups either with respect to the security of the supplied contraceptive methods or to the development of side effects.

  18. A novel reverse-genetic approach (SIMF) identifies Mutator insertions in new Myb genes.

    Science.gov (United States)

    Rabinowicz, P D; Grotewold, E

    2000-11-01

    We have developed a new strategy designated SIMF (Systematic Insertional Mutagenesis of Families), to identify DNA insertions in many members of a gene family simultaneously. This method requires only a short amino acid sequence conserved in all members of the family to make a degenerate oligonucleotide, and a sequence from the end of the DNA insertion. The SIMF strategy was successfully applied to the large maize R2R3 Myb family of regulatory genes, and Mutator insertions in several novel Myb genes were identified. Application of this technique to identify insertions in other large gene families could significantly decrease the effort involved in screening at the same time for insertions in all members of groups of genes that share a limited sequence identity.

  19. Mechanism of lithium insertion into NiSi2 anode material for lithium ion batteries

    Institute of Scientific and Technical Information of China (English)

    WEN Zhongsheng; JI Shijun; SUN Juncai; TIAN Feng; TIAN Rujin; XIE Jingying

    2006-01-01

    As a promising high capacity anode material for lithium ion batteries, the lithium insertion performance and possible insertion mechanism of binary alloy of NiSi2 were discussed. The initial lithium insertion of crystal NiSi2 can reach up to 600 mAh·g-1 , but large irreversible capacity occurrs simultaneously for serious structure transformation and the irreversible phase forms. XRD and XPS were employed to detect the crystal structure and composition changes produced by lithium insertion. The lithium insertion-extraction behavior of NiSi2 electrode is similar to that of silicon after the first discharge. The structure stability seems related to the non-stoichimometric Ni-Si compound formed by lithium insertion into NiSi2.

  20. Using ΦC31 integrase to mediate insertion of DNA in Xenopus embryos.

    Science.gov (United States)

    Li, You E; Allen, Bryan G; Weeks, Daniel L

    2012-01-01

    The two most common methods used to generate transgenic Xenopus embryos, restriction enzyme-mediated insertion, and I-SceI meganuclease take advantage of relatively common but spatially unpredictable double-stranded breaks in sperm, egg, or early embryo genomes. These methods also tend to insert multimeric copies of the transgene. An alternative is to use bacteriophage- or transposon-derived integrase or recombinase to mediate more site-specific insertion of the transgene. The use of phiC31 integrase requires a defined sequence for insertion and is compatible with insertion of a single copy of the transgene. We describe the protocol we use to facilitate phiC31 integrase transgene insertion including the use of insulator sequences to reduce position effect disruption of transgene activity.

  1. Nelaton catheter assisted versus standard nasogastric tube insertion: a randomized, clinical trial.

    Science.gov (United States)

    Ghaemi, M; Mousavinasab, N; Jalili, S

    2014-01-09

    It is sometimes difficult to insert a nasogastric tube in an anaesthetized patient. We evaluated the benefit of reinforcing the distal portion of the nasogastric tube with a Nelaton catheter: 8 and 10 French Nelaton catheters were inserted into 16 and 18 French nasogastric tubes respectively through the first proximal holes of tubes up to their tips. The patients anaesthetized were randomly allocated into either the control or the Nelaton groups, and nasogastric tube was inserted as deeply as the catheter length, then the catheter was withdrawn and the tube was inserted farther to reach the stomach. Eighty patients (40 in each group) were included in this study. The success rate of nasogastric tube insertion was 90% in the Nelaton group and 57% in the control group (P = 0.001). The mean insertion time was 80 (SD 43) and 92 (SD 35) seconds in the Nelaton and the control groups respectively.

  2. Structural and biophysical analysis of sequence insertions in the Venezuelan Equine Encephalitis Virus macro domain.

    Science.gov (United States)

    Guillén, Jaime; Lichière, Julie; Rabah, Nadia; Beitzel, Brett F; Canard, Bruno; Coutard, Bruno

    2015-04-01

    Random transposon insertions in viral genomes can be used to reveal genomic regions important for virus replication. We used these genomic data to evaluate at the protein level the effect of such insertions on the Venezuelan Equine Encephalitis Virus nsP3 macro domain. The structural analysis showed that transposon insertions occur mainly in loops connecting the secondary structure elements. Some of the insertions leading to a temperature sensitive viral phenotype (ts) are close to the cleavage site between nsP2 and nsP3 or the ADP-ribose binding site, two important functions of the macro domain. Using four mutants mimicking the transposon insertions, we confirmed that these insertions can affect the macro domain properties without disrupting the overall structure of the protein.

  3. JOINT MOBILIZATION IN THE MANAGEMENT OF PERSISTENT INSERTIONAL ACHILLES TENDINOPATHY: A CASE REPORT

    Science.gov (United States)

    Post, Andrew A.; Mischke, John J.; Sault, Josiah D.

    2017-01-01

    Background & Purpose Insertional Achilles tendinopathy (IAT) can be a challenging condition to manage conservatively. Eccentric exercise is commonly used in the management of chronic tendinopathy; however, it may not be as helpful for insertional tendon problems as compared to mid-portion dysfunction. While current evidence describing the physical therapy management of IAT is developing, gaps still exist in descriptions of best practice. The purpose of this case report is to describe the management of a patient with persistent IAT utilizing impairment-based joint mobilization, self-mobilization, and exercise. Case description A 51-year-old male was seen in physical therapy for complaints of posterior heel pain and reduced running capacity. He was seen by multiple physical therapists previously, but reported continued impairment, and functional restriction. Joint-based non-thrust mobilization and self-mobilization exercise were performed to enhance his ability to run and reduce symptoms. Outcomes The subject was seen for four visits over the course of two months. He made clinically significant improvements on the Foot and Ankle Activity Measure and Victorian Institute of Sport Assessment-Achilles tendon outcomes, was asymptomatic, and participated in numerous marathons. Improvements were maintained at one-year follow-up. Discussion Mobility deficits can contribute to the development of tendinopathy, and without addressing movement restrictions, symptoms and functional decline related to tendinopathy may persist. Joint-directed manual therapy may be a beneficial intervention in a comprehensive plan of care in allowing patients with chronic tendon changes to optimize function. Level of Evidence Therapy, Level 4 PMID:28217424

  4. Analysis of the cooldown of the ITER central solenoid model coil and insert coil

    Science.gov (United States)

    Bonifetto, R.; Brighenti, A.; Isono, T.; Martovetsky, N.; Kawano, K.; Savoldi, L.; Zanino, R.

    2017-01-01

    A series of superconducting insert coils (ICs) made of different materials has been tested since 2000 at JAEA Naka in the bore of the central solenoid model coil at fields up to 13 T and currents up to several tens of kA, fully representative of the ITER operating conditions. Here we focus on the 2015 test of the presently last IC of the series, the central solenoid (CS) insert coil, which was aimed at confirming the performance and properties of the Nb3Sn conductor, manufactured in Japan and used to wind the ITER CS modules in the US. As typical for these large scale applications, the cooldown (CD) from ambient to supercritical He temperature may take a long time, of the order of several weeks, so that it should be useful, also in the perspective of future IC tests, to optimize it. To that purpose, a comprehensive CD model implemented in the 4C code is developed and presented in this paper. The model is validated against the experimental data of an actual CD scenario, showing a very good agreement between simulation and measurements, from 300 to 4.5 K. The maximum temperature difference across the coil, which can only be roughly estimated from the measurements, is then extracted from the results of the simulation and shown to be much larger than the maximum value of 50 K, prescribed on the basis of the allowable thermal stress on the materials. An optimized CD scenario is finally designed using the model for the initial phase of the CD between 300 and 80 K, which allows reducing the needed time by ∼20%, while still satisfying the major constraints. Recommendations are also given for a better location/choice of the thermometers to be used for the monitoring of the maximum temperature difference across the coil.

  5. A prototype MR insertable brain PET using tileable GAPD arrays.

    Science.gov (United States)

    Hong, Key Jo; Choi, Yong; Jung, Jin Ho; Kang, Jihoon; Hu, Wei; Lim, Hyun Keong; Huh, Yoonsuk; Kim, Sangsu; Jung, Ji Woong; Kim, Kyu Bom; Song, Myung Sung; Park, Hyun-Wook

    2013-04-01

    The aim of this study was to develop a prototype magnetic resonance (MR)-compatible positron emission tomography (PET) that can be inserted into a MR imager and that allows simultaneous PET and MR imaging of the human brain. This paper reports the initial results of the authors' prototype brain PET system operating within a 3-T magnetic resonance imaging (MRI) system using newly developed Geiger-mode avalanche photodiode (GAPD)-based PET detectors, long flexible flat cables, position decoder circuit with high multiplexing ratio, and digital signal processing with field programmable gate array-based analog to digital converter boards. A brain PET with 72 detector modules arranged in a ring was constructed and mounted in a 3-T MRI. Each PET module was composed of cerium-doped lutetium yttrium orthosilicate (LYSO) crystals coupled to a tileable GAPD. The GAPD output charge signals were transferred to preamplifiers using 3 m long flat cables. The LYSO and GAPD were located inside the MR bore and all electronics were positioned outside the MR bore. The PET detector performance was investigated both outside and inside the MRI, and MR image quality was evaluated with and without the PET system. The performance of the PET detector when operated inside the MRI during MR image acquisition showed no significant change in energy resolution and count rates, except for a slight degradation in timing resolution with an increase from 4.2 to 4.6 ns. Simultaneous PET/MR images of a hot-rod and Hoffman brain phantom were acquired in a 3-T MRI. Rods down to a diameter of 3.5 mm were resolved in the hot-rod PET image. The activity distribution patterns between the white and gray matter in the Hoffman brain phantom were well imaged. The hot-rod and Hoffman brain phantoms on the simultaneously acquired MR images obtained with standard sequences were observed without any noticeable artifacts, although MR image quality requires some improvement. These results demonstrate that the

  6. Hot Machining of Hardened Steels with Coated Carbide Inserts

    Directory of Open Access Journals (Sweden)

    M. A. Lajis

    2009-01-01

    Full Text Available Problem statement: The benefits of easier manufacture of hardened steel components can be substantial in terms of reduced machining costs and lead times compared to the traditional route involving machining of the annealed state followed by heat treatment, grinding/EDM and manual finishing. But machinability of hard material through conventional machining is hindered due to excessive wear of the cutting tools and differently in achieving desired quality of the machined surface. In end milling the cutting tool is not in constant operation and so undergoes a heat cycle during the intermittent cutting. This alternate heating and cooling of the inserts lead to the thermal cracks and subsequently failure of the tool. Approach: This study was conducted to investigate the effect of preheating through inductive heating mechanism in end milling (vertical milling center of AISI D2 hardened steel (56-62 HRC by using coated carbide tool inserts. Apart from preheating, two other machining parameters such as cutting speed and feed were varied while the depth of cut was kept constant. Results: Tool wear phenomenon and machined surface finish were found to be significantly affected by preheating temperature and other two variables. Preheating temperature of 335°C coupled with cutting speed of 40 m min-1, depth of cut of 1.0 mm and feed of 0.02 mm/tooth resulted in a noticeable reduction in tool wear rate leading to a maximum tool life 188.55 min. In addition, cutting speed of 56.57 m min-1 together with feed of 0.044 mm/tooth and depth of cut 1.0 mm at which maximum VMR (9500 mm3 was secured provides a better surface finish with minimum surface roughness 0.25µm leaving a possibility of skipping the grinding and polishing operations for certain applications. Conclusion/Recommendation: Through the end milling of preheated AISI D2 hardened steel by using TiAlN coated carbide cutting tool it can be concluded that an overall enhanced machinability is achievable by

  7. Early versus Delayed Insertion of Intrauterine Contraception after Medical Abortion — A Randomized Controlled Trial

    Science.gov (United States)

    Sääv, Ingrid; Stephansson, Olof; Gemzell-Danielsson, Kristina

    2012-01-01

    Background Today, a large proportion of early abortions are medical terminations, in accordance to the woman's choice. Intrauterine contraceptives (IUC) provide highly effective, reversible, long-acting contraception. However, the effects of timing of IUC insertion after medical abortion are not known. Methods Women undergoing medical abortion with mifepristone and misoprostol up to 63 days gestation and opting for IUC were randomised to early insertion (day 5–9 after mifepristone) or delayed (routine) insertion (at 3–4 weeks after mifepristone). The primary outcome was the rate of IUC expulsion at six months after IUC insertion. Results A total of 129 women were randomized, and 116 women had a successful IUC insertion. There was no difference in expulsion rate between early (9.7%) vs. delayed (7.4%) IUC insertion (risk difference −9.2–13.4). Furthermore, 1.5% of women randomized to early and 11.5% to delayed insertion did not attend the follow up (proportion difference 10.0%, 95% CI: 1.8–20.6%, p = 0.015), and a higher proportion of women (41%) had had unprotected intercourse prior to returning for insertion in the delayed group compared with the early group (16%) (p = 0.015). Adverse events were rare and did not differ between the groups. Conclusions Early insertion of IUC after medical abortion was safe and well tolerated with no increased incidence for expulsions or complications. Women were more likely to return for the IUC insertion if scheduled early after the abortion, and less likely to have had an unprotected intercourse prior to the IUC insertion. Early insertion should be offered as a routine for women undergoing first trimester medical abortion. Trial Registration ClinicalTrials.gov NCT01537562 PMID:23155432

  8. Exponential megapriming PCR (EMP) cloning--seamless DNA insertion into any target plasmid without sequence constraints.

    Science.gov (United States)

    Ulrich, Alexander; Andersen, Kasper R; Schwartz, Thomas U

    2012-01-01

    We present a fast, reliable and inexpensive restriction-free cloning method for seamless DNA insertion into any plasmid without sequence limitation. Exponential megapriming PCR (EMP) cloning requires two consecutive PCR steps and can be carried out in one day. We show that EMP cloning has a higher efficiency than restriction-free (RF) cloning, especially for long inserts above 2.5 kb. EMP further enables simultaneous cloning of multiple inserts.

  9. Early versus delayed insertion of intrauterine contraception after medical abortion - a randomized controlled trial.

    Directory of Open Access Journals (Sweden)

    Ingrid Sääv

    Full Text Available BACKGROUND: Today, a large proportion of early abortions are medical terminations, in accordance to the woman's choice. Intrauterine contraceptives (IUC provide highly effective, reversible, long-acting contraception. However, the effects of timing of IUC insertion after medical abortion are not known. METHODS: Women undergoing medical abortion with mifepristone and misoprostol up to 63 days gestation and opting for IUC were randomised to early insertion (day 5-9 after mifepristone or delayed (routine insertion (at 3-4 weeks after mifepristone. The primary outcome was the rate of IUC expulsion at six months after IUC insertion. RESULTS: A total of 129 women were randomized, and 116 women had a successful IUC insertion. There was no difference in expulsion rate between early (9.7% vs. delayed (7.4% IUC insertion (risk difference -9.2-13.4. Furthermore, 1.5% of women randomized to early and 11.5% to delayed insertion did not attend the follow up (proportion difference 10.0%, 95% CI: 1.8-20.6%, p = 0.015, and a higher proportion of women (41% had had unprotected intercourse prior to returning for insertion in the delayed group compared with the early group (16% (p = 0.015. Adverse events were rare and did not differ between the groups. CONCLUSIONS: Early insertion of IUC after medical abortion was safe and well tolerated with no increased incidence for expulsions or complications. Women were more likely to return for the IUC insertion if scheduled early after the abortion, and less likely to have had an unprotected intercourse prior to the IUC insertion. Early insertion should be offered as a routine for women undergoing first trimester medical abortion. TRIAL REGISTRATION: ClinicalTrials.gov NCT01537562.

  10. Radiological insertion of Tenckhoff catheters for peritoneal dialysis: a 1-year single-centre experience

    OpenAIRE

    Quach, Trung; Tregaskis, Peter; Menahem, Solomon; Koukounaras, Jim; Mott, Nigel; Walker, Rowan G

    2013-01-01

    Background Peritoneal dialysis (PD) is an important home-based dialysis modality for patients with end-stage kidney disease (ESKD). The initiation of PD requires timely and skilled insertion of a Tenckhoff catheter (TC). At most centres, TCs are inserted laparoscopically by surgeons under general anaesthetic. This requires access to increasingly scarce surgical, anaesthetic and hospital inpatient resources. Radiological insertion of TCs performed as a day procedure under local anaesthetic all...

  11. Rotational path of insertion for removable partial dentures with an anterior saddle.

    Science.gov (United States)

    Yip, Kevin H-K; Fang, Daniel T-S; Smales, Roger J; Newsome, Philip R H; Chow, Tak W

    2003-01-01

    The provision of removable partial dentures remains a viable treatment modality for many partially dentate patients. Replacing missing anterior teeth with a removable partial denture using a rotational path of insertion provides improved retention and appearance. The use of a rotational path of insertion also provides additional retention for a removable partial denture restoring combined anterior and posterior bounded saddles. Two case reports demonstrate the use of the rotational path of insertion for partial denture design.

  12. Exponential megapriming PCR (EMP cloning--seamless DNA insertion into any target plasmid without sequence constraints.

    Directory of Open Access Journals (Sweden)

    Alexander Ulrich

    Full Text Available We present a fast, reliable and inexpensive restriction-free cloning method for seamless DNA insertion into any plasmid without sequence limitation. Exponential megapriming PCR (EMP cloning requires two consecutive PCR steps and can be carried out in one day. We show that EMP cloning has a higher efficiency than restriction-free (RF cloning, especially for long inserts above 2.5 kb. EMP further enables simultaneous cloning of multiple inserts.

  13. A Glutamic Acid-Rich Protein Identified in Verticillium dahliae from an Insertional Mutagenesis Affects Microsclerotial Formation and Pathogenicity

    Science.gov (United States)

    Li, Guo-Ying; Jia, Pei-Song; Li, Hui; Zhao, Yun-Long; Zhao, Pan; Xia, Gui-Xian; Guo, Hui-Shan

    2010-01-01

    Verticillium dahliae Kleb. is a phytopathogenic fungus that causes wilt disease in a wide range of crops, including cotton. The life cycle of V. dahliae includes three vegetative phases: parasitic, saprophytic and dormant. The dormant microsclerotia are the primary infectious propagules, which germinate when they are stimulated by root exudates. In this study, we report the first application of Agrobacterium tumefaciens-mediated transformation (ATMT) for construction of insertional mutants from a virulent defoliating isolate of V. dahliae (V592). Changes in morphology, especially a lack of melanized microsclerotia or pigmentation traits, were observed in mutants. Together with the established laboratory unimpaired root dip-inoculation approach, we found insertional mutants to be affected in their pathogenicities in cotton. One of the genes tagged in a pathogenicity mutant encoded a glutamic acid-rich protein (VdGARP1), which shared no significant similarity to any known annotated gene. The vdgarp1 mutant showed vigorous mycelium growth with a significant delay in melanized microsclerotial formation. The expression of VdGARP1 in the wild type V529 was organ-specific and differentially regulated by different stress agencies and conditions, in addition to being stimulated by cotton root extract in liquid culture medium. Under extreme infertile nutrient conditions, VdGARP1 was not necessary for melanized microsclerotial formation. Taken together, our data suggest that VdGARP1 plays an important role in sensing infertile nutrient conditions in infected cells to promote a transfer from saprophytic to dormant microsclerotia for long-term survival. Overall, our findings indicate that insertional mutagenesis by ATMT is a valuable tool for the genome-wide analysis of gene function and identification of pathogenicity genes in this important cotton pathogen. PMID:21151869

  14. Development and comparison of projection and image space 3D nodule insertion techniques

    Science.gov (United States)

    Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Samei, Ehsan

    2016-04-01

    This study aimed to develop and compare two methods of inserting computerized virtual lesions into CT datasets. 24 physical (synthetic) nodules of three sizes and four morphologies were inserted into an anthropomorphic chest phantom (LUNGMAN, KYOTO KAGAKU). The phantom was scanned (Somatom Definition Flash, Siemens Healthcare) with and without nodules present, and images were reconstructed with filtered back projection and iterative reconstruction (SAFIRE) at 0.6 mm slice thickness using a standard thoracic CT protocol at multiple dose settings. Virtual 3D CAD models based on the physical nodules were virtually inserted (accounting for the system MTF) into the nodule-free CT data using two techniques. These techniques include projection-based and image-based insertion. Nodule volumes were estimated using a commercial segmentation tool (iNtuition, TeraRecon, Inc.). Differences were tested using paired t-tests and R2 goodness of fit between the virtually and physically inserted nodules. Both insertion techniques resulted in nodule volumes very similar to the real nodules (<3% difference) and in most cases the differences were not statistically significant. Also, R2 values were all <0.97 for both insertion techniques. These data imply that these techniques can confidently be used as a means of inserting virtual nodules in CT datasets. These techniques can be instrumental in building hybrid CT datasets composed of patient images with virtually inserted nodules.

  15. Recent CR1 non-LTR retrotransposon activity in coscoroba reveals an insertion site preference

    Directory of Open Access Journals (Sweden)

    Quinn Thomas W

    2008-11-01

    Full Text Available Abstract Background Chicken repeat 1 (CR1 is a taxonomically widespread non-LTR retrotransposon. Insertion site bias, or lack thereof, has not been demonstrated for CR1. Recent CR1 retrotranspositions were used to examine flanking regions for GC content and nucleotide bias at the insertion site. Results Elucidation of the exact octomer repeat sequence (TTCTGTGA allowed for the identification of younger insertion events. The number of octomer repeats associated with a CR1 element increases after insertion with CR1s having one octomer being youngest. These young CR1s are flanked by regions of low GC content (38%. Furthermore, a bias for specific bases within the first four positions at the site of insertion was revealed. Conclusion This study focused on those loci where the insertion event has been most recent, as this would tend to minimize noise introduced by post-integration mutational events. Our data suggest that CR1 is not inserting into regions of higher GC content within the coscoroba genome; but rather, preferentially inserting into regions of lower GC content. Furthermore, there appears to be a base preference (TTCT for the insertion site. The results of this study increase the current level of understanding regarding the elusive CR1 non-LTR retrotransposon.

  16. [A comparative study of T Cu-200 insertions by medical doctors and midwives].

    Science.gov (United States)

    Marangoni, P; Pozo, A; Faundes, A

    1976-01-01

    The Asociacion Pro Bienestar de la Familia Ecuadoriana has employed since 1965 midwives to perform clinical services. This comparative study investigates 310 insertions of T Cu-200 done by physicians, and 297 insertions of the same IUD type done by midwives. Age and parity of acceptors were comparable in both groups. Insertions were executed by midwives with as much skill and knowledge as the doctors, and termination rates for medical reasons were almost similar in both groups. Several authors have confirmed the fact that experienced midwives can be successfully trained in performing IUD insertions.

  17. Insertional translocations: report of two new families and review of the literature.

    Science.gov (United States)

    Abuelo, D N; Barsel-Bowers, G; Richardson, A

    1988-10-01

    We describe two families with insertional translocations. In the first, a large family ascertained because of repeated pregnancy loss, the insertional translocation, ins(1;3)(q32;p13pter), was found to be segregating through three generations. In the second family, ascertained through a proposita with congenital malformations, multiple spontaneous abortions also occurred. The father had an insertional translocation, inv 4(p14,q21.1)ins(7,4)(q32;q21.1 q23). These cases illustrate that recurrent fetal wastage may be caused by insertional translocations and in fact may be the only clinical manifestation of this unusual type of chromosome rearrangement.

  18. Exchange of peripherally inserted central catheters is associated with an increased risk for bloodstream infection.

    Science.gov (United States)

    McCoy, Michael; Bedwell, Susan; Noori, Shahab

    2011-06-01

    It is not uncommon that the peripherally inserted central catheter (PICC) needs to be replaced either due to blockage or migration to a peripheral position. In such circumstances, there are two methods of PICC placement: new-site insertion and exchange by using the old PICC as a guide wire. Our objective was to investigate risk of infection associated with the exchange method. In this retrospective study, data on all PICC insertions in the neonatal intensive care unit in 2004 to 2008 were obtained. In the population who needed removal of existing PICC and insertion of a new one, we compared central line-associated bloodstream infection (CLABSI) within 1 week of insertion between the two insertion methods. Of 1148 PICC insertions reviewed, 164 (103 new-site and 61 exchange insertions) were performed after removal of a blocked/malpositioned PICC and therefore comprised the study population. The rate of CLABSI was higher in the exchange method (9.8% versus 1%, P exchange method (odds ratio 25.2, 95% confidence interval: 2.17 to 292.98; P = 0.01). In infants, insertion of PICCs using the exchange method carries an increased risk of bloodstream infection.

  19. A new modified Seldinger technique for 2- and 3-French peripherally inserted central venous catheters.

    Science.gov (United States)

    Wald, Martin; Happel, Christoph M; Kirchner, Lieselotte; Jeitler, Valerie; Sasse, Michael; Wessel, Armin

    2008-11-01

    This study describes a modified Seldinger technique for 2- and 3-French peripherally inserted central venous catheters: A device similar to that used in heart catherisation with a standard micro-introducer serving as sheath and an arterial catheter serving as inner dilator was pushed forward over a wire guide that had before been inserted via a peripheral venous catheter. With this method 2-and 3-French catheters could be safely inserted into peripheral veins of 14 paediatric patients. In conclusion successful insertion of a small peripheral venous catheter offers in most cases a possibility for the placement of a central venous line.

  20. Insertion Polymorphisms of Mobile Genetic Elements in Sexual and Asexual Populations of Daphnia pulex

    Science.gov (United States)

    Ye, Zhiqiang; Lynch, Michael

    2017-01-01

    Transposable elements (TEs) constitute a substantial portion of many eukaryotic genomes, and can in principle contribute to evolutionary innovation as well as genomic deterioration. Daphnia pulex serves as a useful model for studying TE dynamics as a potential cause and/or consequence of asexuality. We analyzed insertion polymorphisms of TEs in 20 sexual and 20 asexual isolates of D. pulex across North American from their available whole-genome sequencing data. Our results show that the total fraction of the derived sequences of TEs is not substantially different between asexual and sexual D. pulex isolates. However, in general, sexual clones contain fewer fixed TE insertions but more total insertion polymorphisms than asexual clones, supporting the hypothesis that sexual reproduction facilitates the spread and elimination of TEs. We identified nine asexual-specific fixed TE insertions, eight long terminal repeat retrotransposons, and one DNA transposon. By comparison, no sexual-specific fixed TE insertions were observed in our analysis. Furthermore, except one TE insertion located on a contig from chromosome 7, the other eight asexual-specific insertion sites are located on contigs from chromosome 9 that is known to be associated with obligate asexuality in D. pulex. We found that all nine asexual-specific fixed TE insertions can also be detected in some Daphnia pulicaria isolates, indicating that a substantial number of TE insertions in asexual D. pulex have been directly inherited from D. pulicaria during the origin of obligate asexuals. PMID:28057730

  1. Insertion polymorphisms of mobile genetic elements in sexual and asexual populations of Daphnia pulex.

    Science.gov (United States)

    Jiang, Xiaoqian; Tang, Haixu; Ye, Zhiqiang; Lynch, Michael

    2017-01-04

    Transposable elements (TEs) constitute a substantial portion of many eukaryotic genomes, and can in principle contribute to evolutionary innovation as well as genomic deterioration. Daphnia pulex serves as a useful model for studying TE dynamics as a potential cause and/or consequence of asexuality. We analyzed insertion polymorphisms of TEs in 20 sexual and 20 asexual isolates of D. pulex across North American from their available whole-genome sequencing data. Our results show that the total fraction of the derived sequences of TEs is not substantially different between asexual and sexual D. pulex isolates. However, in general, sexual clones contain fewer fixed TE insertions but more total insertion polymorphisms than asexual clones, supporting the hypothesis that sexual reproduction facilitates the spread and elimination of TEs. We identified 9 asexual-specific fixed TE insertions, 8 LTR retrotransposons and 1 DNA transposon. By comparison, no sexual-specific fixed TE insertions were observed in our analysis. Furthermore, except 1 TE insertion located on a contig from chromosome 7, the other 8 asexual-specific insertion sites are located on contigs from chromosome 9 that is known to be associated with obligate asexuality in D. pulex. We found that all 9 asexual-specific fixed TE insertions can also be detected in some D. pulicaria isolates, indicating that a substantial number of TE insertions in asexual D. pulex have been directly inherited from D. pulicaria during the origin of obligate asexuals.

  2. Insertion trauma of a cochlear implant electrode array with Nitinol inlay.

    Science.gov (United States)

    Rau, Thomas S; Harbach, Lenka; Pawsey, Nick; Kluge, Marcel; Erfurt, Peter; Lenarz, Thomas; Majdani, Omid

    2016-11-01

    The integration of a shape memory actuator is a potential mechanism to achieve a consistent perimodiolar position after electrode insertion during cochlear implant surgery. After warming up, and therefore activation of the shape memory effect, the electrode array will change from a straight configuration into a spiral shaped one leading to a final position close to the modiolus. The aim of this study was to investigate whether the integration of an additional thin wire (referred to as an "inlay") made of Nitinol, a well-established shape memory alloy, in a conventional hearing preservation electrode array will affect the insertion behaviour in terms of increased risk of insertion trauma. Six conventional Hybrid-L electrode arrays (Cochlear Ltd., Sydney, Australia) were modified to incorporate a wire inlay made of Nitinol. The diameter of the wires was 100 µm with a tapered tip region. Electrodes were inserted into human temporal bone specimens using a standard surgical approach. After insertion and embedding in epoxy resin, histological sections were prepared to evaluate insertion trauma. Insertion was straightforward and no difficulties were observed. The addition of a shape memory wire, thin but also strong enough to curl the electrode array, does not result in histologically detectable insertion trauma. Atraumatic insertion seems possible.

  3. Insert size of YAC clones - RGP physicalmap | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available [ Credits ] BLAST Search Image Search Home About Archive Update History Contact us RGP physical...a contents Insert size of YAC clones in the physical map Data file File name: rgp_physicalmap_insert_size.zi...p File URL: ftp://ftp.biosciencedbc.jp/archive/rgp-physicalmap/LATEST/rgp_physical...map_insert_size.zip File size: 3.4 KB Simple search URL http://togodb.biosciencedbc.jp/togodb/view/rgp_physical...ase Description Download License Update History of This Database Site Policy | Contact Us Insert size of YAC clones - RGP physicalmap | LSDB Archive ...

  4. Heat transfer enhancement in smooth tube with wire coil insert in laminar and transitional non-newtonian flow

    OpenAIRE

    García Pinar, Alberto; Solano Fernández, Juan Pedro; Viedma Robles, Antonio; Martínez Hernández, David Sebastián

    2010-01-01

    This work presents an experimental study on the heat transfer enhancement by means of a tube with wire-coil insert,for non-Newtonian laminar and transitional flow. The dimensionless pitch and wire diameter (based on the plain tube inner diameter) were chosen as p/D= 1 and e/D=0.09. Two pseudoplastic test fluids have been used: 1% by weight aqueous solutions of carboxymethyl cellulose (CMC) with high viscosity and medium viscosity. A wide range of flow conditions has been covered: Reynolds ...

  5. Electron mobility enhancement in (100) oxygen-inserted silicon channel

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Nuo; King Liu, Tsu-Jae [Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720 (United States); Takeuchi, Hideki; Hytha, Marek; Cody, Nyles W.; Stephenson, Robert J.; Mears, Robert J. [Mears Technologies, Inc., Wellesley Hills, Massachusetts 02481 (United States); Kwak, Byungil; Cha, Seon Yong [SK Hynix, Icheon-si, Gyeonggi-do 467-701 (Korea, Republic of)

    2015-09-21

    High performance improvement (+88% in peak G{sub m} and >30% in linear and saturation region drain currents) was observed for N-MOSFETs with Oxygen-Inserted (OI) Si channel. From TCAD analysis of the C-V measurement data, the improvement was confirmed to be due to electron mobility enhancement of the OI Si channel (+75% at N{sub inv} = 4.0 × 10{sup 12} cm{sup −2} and +25% at N{sub inv} = 8.0 × 10{sup 12} cm{sup −2}). Raman and high-resolution Rutherford backscattering measurements confirmed that negligible strain is induced in the OI Si layer, and hence, it cannot be used to explain the origin of mobility improvement. Poisson-Schrödinger based quantum mechanical simulation was performed, taking into account phonon, surface roughness and Coulomb scatterings. The OI layer was modeled as a “quasi barrier” region with reference to the Si conduction band edge to confine inversion electrons. Simulation explains the measured electron mobility enhancement as the confinement effect of inversion electrons while the formation of an super-steep retrograde well doping profile in the channel (as a result of dopant diffusion blocking effect accompanied by introduction of the OI layer) also contributes 50%–60% of the mobility improvement.

  6. Design Challenges for a Wide-Aperture Insertion Quadrupole Magnet

    CERN Document Server

    Russenschuck, S; Perez, J C; Ramos, D; Fessia, P; Karppinen, M; Kirby, G; Sahner, T; Schwerg, N

    2011-01-01

    The design and development of a superconducting (Nb-Ti) quadrupole with 120 mm aperture, for an upgrade of the LHC insertion region, faces challenges arising from the LHC beam optics requirements and the heat-deposition. The first triggered extensive studies of coil alternatives with four and six coil-blocks in view of field quality and operation margins. The latter requires more porous insulation schemes for both the cables and the ground-plane. This in turn necessitates extensive heatpropagation and quench-velocity studies, as well as more efficient quench heaters. The engineering design of the magnet includes innovative features such as self-locking collars, which will enable the collaring to be performed with the coils on a horizontal assembly bench, a spring-loaded and collapsible assembly mandrel, tuning-shims for field quality, porous collaring-shoes, and coil end-spacer design based on differential geometry methods. The project also initiated code extensions in the quench-simulation and CAD/CAM module...

  7. Insertion of tetracysteine motifs into dopamine transporter extracellular domains.

    Directory of Open Access Journals (Sweden)

    Deanna M Navaroli

    Full Text Available The neuronal dopamine transporter (DAT is a major determinant of extracellular dopamine (DA levels and is the primary target for a variety of addictive and therapeutic psychoactive drugs. DAT is acutely regulated by protein kinase C (PKC activation and amphetamine exposure, both of which modulate DAT surface expression by endocytic trafficking. In order to use live imaging approaches to study DAT endocytosis, methods are needed to exclusively label the DAT surface pool. The use of membrane impermeant, sulfonated biarsenic dyes holds potential as one such approach, and requires introduction of an extracellular tetracysteine motif (tetraCys; CCPGCC to facilitate dye binding. In the current study, we took advantage of intrinsic proline-glycine (Pro-Gly dipeptides encoded in predicted DAT extracellular domains to introduce tetraCys motifs into DAT extracellular loops 2, 3, and 4. [(3H]DA uptake studies, surface biotinylation and fluorescence microscopy in PC12 cells indicate that tetraCys insertion into the DAT second extracellular loop results in a functional transporter that maintains PKC-mediated downregulation. Introduction of tetraCys into extracellular loops 3 and 4 yielded DATs with severely compromised function that failed to mature and traffic to the cell surface. This is the first demonstration of successful introduction of a tetracysteine motif into a DAT extracellular domain, and may hold promise for use of biarsenic dyes in live DAT imaging studies.

  8. PNEUMOPERITO NEUM BY DIRECT TROCAR INSERTION : SAFE LAPAROSCOPIC ACCESS

    Directory of Open Access Journals (Sweden)

    Rajneesh

    2015-02-01

    Full Text Available Purpose of this study is to access the safety and efficacy of direct trocar insertion (DTI for accessing the abdominal cavity for operative laparoscopy without prior pneumoperitoneum. DTI is one of the safe and effective alternative to veress needle inser tion , open access (Hassan’s technique and visual entry systems (disposable optic trocars and endotip visual cannula in laparoscopic surgery. METHODS: The study included 2480 patients who has undergone laparoscopic procedures at civil hospital , Jalandhar from Nov . 2003 to Sept . 2012 and at Punjab Institu t e of Medical Sciences ( PIMS Jalandhar from S ept . 2012 to June 2014. Procedures include 2310 laparoscopic cholecystectomies , 148 laparoscopic appendectomies , 10 cases of TAPP Groin hernia repairs and 12 cases of simple ovarian cysts. For DTI , abdominal wall was lifted and trocar was pushed through the fascia and muscle layer. The surgeon felt click when the trocar had pierced the peritoneum and entered the abdominal cavity. RESULTS: Direct trocar insertio n was feasible in 100% of patients. There was no evidence of intestinal or vascular injury during trocar placement. Peritoneal access and creation of laparoscopic workspace were attained faster and more efficiently by the DTI technique. CONCLUSIONS: DTI is a fast , safe and reliable alternative to traditional techniques of primary port placement in laparoscopic procedures for creation of pnuemoperitoneum.

  9. MENTAL DISORDER AFFECTS THE LABORAL INSERTION AND THE INFORMAL SECTOR?

    Directory of Open Access Journals (Sweden)

    M. M. F Léo

    2017-08-01

    Full Text Available The study characterized the insertion in the labor market, scholar degree and economic status of people with mental disorders. It is a descriptive cross-sectional study, conducted in 2014, in two open psychosocial care services in Mato Grosso. A structured questionnaire with demographic data and school/ work functioning during the years of mental disorderwas applied in a random sample of 73 patients (universe = 300. Of the 61 (83.6% who worked before the mental disorder, 26 (35.6% are still active. There was a decrease of 38.5% in formality with informality rise. Licenses (19.0% and pensions (28.6% were prevalent male, and 57.1% of absences are related to mental disorder. Unemployment reached 37%, especially those over 55 years (41.7%. Mental disorder damagescause exclusion from the labor market, increasing informality, affectssocial pension and reinforce the vulnerability of this population, constituting topic to be included in the nursing SingularTherapeutic Project

  10. Theory of electromagnetic insertion devices and the corresponding synchrotron radiation

    Science.gov (United States)

    Shumail, Muhammad; Tantawi, Sami G.

    2016-07-01

    Permanent magnet insertion devices (IDs), which are the main radiation generating devices in synchrotron light sources and free-electron lasers, use a time-invariant but space-periodic magnetic field to wiggle relativistic electrons for short-wavelength radiation generation. Recently, a high power microwave based undulator has also been successfully demonstrated at SLAC which promises the advantage of dynamic tunability of radiation spectrum and polarization. Such IDs employ transverse elecromagnetic fields which are periodic in both space and time to undulate the electrons. In this paper we develop a detailed theory of the principle of electromagnetic IDs from first principles for both linear and circular polarization modes. The electromagnetic equivalent definitions of undulator period (λu) and undulator deflection parameter (K ) are derived. In the inertial frame where the average momentum of the electron is zero, we obtain the figure-8-like trajectory for the linear polarization mode and the circular trajectory for the circular polarization mode. The corresponding radiation spectra and the intensity of harmonics is also calculated.

  11. Insertions/deletions-associated nucleotide polymorphism in Arabidopsis thaliana

    Directory of Open Access Journals (Sweden)

    Changjiang Guo

    2016-11-01

    Full Text Available Although high levels of within-species variation are commonly observed, a general mechanism for the origin of such variation is still lacking. Insertions and deletions (indels are a widespread feature of genomes and we hypothesize that there might be an association between indels and patterns of nucleotide polymorphism. Here, we investigate flanking sequences around 18 indels (>100bp among a large number of accessions of the plant, Arabidopsis thaliana. We found two distinct haplotypes, i.e. a nucleotide dimorphism, present around each of these indels and dimorphic haplotypes always corresponded to the indel-present/-absent patterns. In addition, the peaks of nucleotide diversity between the two divergent alleles were closely associated with these indels. Thus, there exists a close association between indels and dimorphisms. Further analysis suggests that indel-associated substitutions could be an important component of genetic variation shaping nucleotide polymorphism in Arabidopsis. Finally, we suggest a mechanism by which indels might generate these highly divergent haplotypes. This study provides evidence that nucleotide dimorphisms, which are frequently regarded as evidence of frequency-dependent selection, could be explained simply by structural variation in the genome.

  12. Mitochondrial DNA insertions in the nuclear Capra hircus genome.

    Science.gov (United States)

    Ning, F Y; Fu, J; Du, Z H

    2017-01-23

    Nuclear mitochondrial pseudogenes (numts), originating from mtDNA insertions into the nuclear genome, have been detected in many species. However, the distribution of numts in the newly published nuclear genome of domestic goat (Capra hircus) has not yet been explored. We used the entire goat mtDNA sequence and nuclear genome, to identify 118 numts using BLAST. Of these, 79 were able to map sequences to the genome. Further analysis showed that the size of the numts ranged from 318 to 9608 bp, and the homologous identity between numts and their respective corresponding mtDNA fragments varied between 65 and 99%. The identified Yunnan black goat numts covered nearly all the mitochondrial genes including mtDNA control region, and were distributed over all chromosomes with the exception of chromosomes 18, 21, and 25. The Y chromosome was excluded from our analysis, as sequence data are currently not available. Among the discovered 79 numts that we were able to map to the genome, 26 relatively complete mitochondrial genes were detected. Our results constitute valuable information for subsequent studies related to mitochondrial genes and goat evolution.

  13. Inserting epidural patient controlled analgesia into a peripheral venous line.

    Science.gov (United States)

    2016-01-01

    A case is reported from the Safety Reporting System in Anaesthesia and Resuscitation database. The event occurred in a patient undergoing abdominal surgery in whom an epidural catheter was inserted for analgesia. After the intervention, the patient was transferred to the recovery unit where the patient controlled analgesia (PCA) is programmed. Due to an error, the PCA was connected to a peripheral venous line, which was detected early without harm to the patient. Communication and analysis of this incident served to introduce a new drug delivery protocol through PCA pumps, including the obligation to prescribe the PCA in the electronic system, a dual computerised check immediately before connecting PCA, labelling the medication bag as well as the proximal and distal lines, standardisation of daily visits to patients, and monthly monitoring of results. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Overview of the ATLAS Insertable B-Layer (IBL) Project

    CERN Document Server

    Grosse-Knetter, J; The ATLAS collaboration

    2011-01-01

    The upgrades for the ATLAS Pixel Detector will be staged in preparation for high luminosity LHC. The first upgrade for the Pixel Detector will be the construction of a new pixel layer which will be installed during the first shutdown of the LHC machine, foreseen in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beam-pipe at a radius of 3.2 cm. The IBL will require the development of several new technologies to cope with increased radiation and pixel occupancy and also to improve the physics performance through reduction of the pixel size and a more stringent material budget. Two different and promising silicon sensor technologies, planar n-in-n and 3D, are currently under investigation for the IBL. An overview of the IBL project, of the module design and the qualification for these sensor technologies with particular emphasis on irradiation and beam tests will be presented.

  15. Overview of the ATLAS Insertable B-Layer (IBL) Project

    CERN Document Server

    Gallrapp, C; The ATLAS collaboration

    2012-01-01

    The upgrades for the ATLAS Pixel Detector will be staged in preparation for high luminosity LHC. The first upgrade for the Pixel Detector will be the construction of a new pixel layer which will be installed during the first shutdown of the LHC machine, foreseen in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beam-pipe at a radius of 3.3 cm. The IBL will require the development of several new technologies to cope with increased radiation and pixel occupancy and also to improve the physics performance through reduction of the pixel size and a more stringent material budget. Two different and promising silicon sensor technologies, planar n-in-n and 3D, are currently under investigation for the IBL. An overview of the IBL project, of the module design and their qualification with particular emphasis on irradiation tests will be presented.

  16. Overview of the ATLAS Insertable B-Layer (IBL) Project

    CERN Document Server

    Kagan, M; The ATLAS collaboration

    2014-01-01

    The first upgrade for the Pixel Detector will be a new pixel layer which is currently under construction and will be installed during the first shutdown of the LHC machine, in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beam-pipe. Two different silicon sensor technologies, planar n-in-n and 3D, will be used, connected with the new generation 130nm IBM CMOS FE-I4 readout chip via solder bump-bonds. A production quality control test bench was setup in the ATLAS inner detector assembly clean room to verify and rate the performance of the detector elements before integration around the beam pipe. An overview of the IBL project, of the module design, the qualification for these sensor technologies, the integration quality control setups and recent results in the construction of this full scale new concept detector is discussed.

  17. Overview of the ATLAS Insertable B-Layer (IBL) Project

    CERN Document Server

    Giordani, M; The ATLAS collaboration

    2012-01-01

    The upgrades for the ATLAS Pixel Detector will be staged in preparation for high luminosity LHC. The first upgrade for the Pixel Detector will be the construction of a new pixel layer which will be installed during the first shutdown of the LHC machine, foreseen in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beam-pipe at a radius of 3.3cm. The IBL will require the development of several new technologies to cope with increased radiation and pixel occupancy and also to improve the physics performance through reduction of the pixel size and a more stringent material budget. Two different and promising silicon sensor technologies, planar n-in-n and 3D, are currently under investigation for the IBL. An overview of the IBL project, of the module design and their qualification with particular emphasis on irradiation tests will be presented.

  18. Test Results for LHC Insertion Region Dipole Magnets

    CERN Document Server

    Muratore, Joseph F; Cozzolino, John P; Ganetis, George; Ghosh, Arup; Gupta, Ramesh C; Harrison, Michael; Kumar-Jain, Animesh; Marone, Andrew; Richard-Plate, Stephen; Schmalzle, Jesse D; Thomas, Richard A; Wanderer, Peter; Willen, Erich; Wu, Kuo-Chen

    2005-01-01

    The Superconducting Magnet Division at Brookhaven National Laboratory (BNL) has made 20 insertion region dipoles for the Large Hadron Collider (LHC) at CERN. These 9.45 m-long, 8 cm aperture magnets have the same coil design as the arc dipoles now operating in the Relativistic Heavy Ion Collider (RHIC) at BNL and are of single aperture, twin aperture, and double cold mass configurations. They produce fields up to 3.8 T for operation at 7.56 TeV. Eighteen of these magnets have been tested at 4.5 K using either forced flow supercritical helium or liquid helium. The testing was especially important for the twin aperture models, which have the most challenging design. In these, the dipole fields in both apertures point in the same direction, unlike LHC arc dipoles. This paper reports on the results of these tests, including spontaneous quench performance, verification of quench protection heater operation, and magnetic field quality. Magnetic field measurements were done at 4.5K and at room temperature, and warm-...

  19. Effects of insertion device on SSRF storage ring

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Shanghai Synchrotron Radiation Facility (SSRF), one of the third generation light sources, aims to produce high brightness and/or high flux X-ray source for users; therefore insertion devices (IDs) are important magnetic elements for SSRF. In this paper, the linear perturbations due to IDs toward its storage ring lattice, such as beta function distortions, tune shifts, emittance growths, and energy spreads are estimated by using analytical formulae, and the nonlinear effects from IDs, especially dynamic aperture, are simulated by using Racetrack code. The results show that (a) the reduction of dynamic aperture from single undulator is negligible, since electron beam energy of 3.5 GeV is high and ID's magnetic field is low, and the beta functions in the middle of straight sections, where ID is located, are well optimized; (b) however, the reduction from single wigglers, especially super-conducting wiggler, is visible, because of its higher magnetic field; (c) effects of each ID on emittance growths and energy spreads are less than 7%.

  20. Using multiple sensors for printed circuit board insertion

    Science.gov (United States)

    Sood, Deepak; Repko, Michael C.; Kelley, Robert B.

    1989-01-01

    As more and more activities are performed in space, there will be a greater demand placed on the information handling capacity of people who are to direct and accomplish these tasks. A promising alternative to full-time human involvement is the use of semi-autonomous, intelligent robot systems. To automate tasks such as assembly, disassembly, repair and maintenance, the issues presented by environmental uncertainties need to be addressed. These uncertainties are introduced by variations in the computed position of the robot at different locations in its work envelope, variations in part positioning, and tolerances of part dimensions. As a result, the robot system may not be able to accomplish the desired task without the help of sensor feedback. Measurements on the environment allow real time corrections to be made to the process. A design and implementation of an intelligent robot system which inserts printed circuit boards into a card cage are presented. Intelligent behavior is accomplished by coupling the task execution sequence with information derived from three different sensors: an overhead three-dimensional vision system, a fingertip infrared sensor, and a six degree of freedom wrist-mounted force/torque sensor.