Hasan, Mohammad; Balasubramaniam, R.; Nahra, Henry; Mackey, Jeff; Hall, Nancy; Frankenfield, Bruce; Harpster, George; May, Rochelle; Mudawar, Issam; Kharangate, Chirag R.;
2016-01-01
A ground-based experimental facility to perform flow boiling and condensation experiments is built in support of the development of the long duration Flow Boiling and Condensation Experiment (FBCE) destined for operation on board of the International Space Station (ISS) Fluid Integrated Rack (FIR). We performed tests with the condensation test module oriented horizontally and vertically. Using FC-72 as the test fluid and water as the cooling fluid, we evaluated the operational characteristics of the condensation module and generated ground based data encompassing the range of parameters of interest to the condensation experiment to be performed on the ISS. During this testing, we also evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, and the heat loss from different components. In this presentation, we discuss representative results of performance testing of the FBCE flow loop. These results will be used in the refinement of the flight system design and build-up of the FBCE which is scheduled for flight in 2019.
Design and performance evaluation of a cryogenic condenser for an in-pile experiment
Graham, R. W.; Crum, R. J.; Hsu, Y.
1972-01-01
An apparatus was designed to enable in-pile irradiation of materials in liquid hydrogen at cryogenic temperatures. One of the principal components of this apparatus was a horizontal tube condenser. The performance of the condenser was evaluated by running a liquid-nitrogen prototype of the apparatus at heat loads comparable to or greater than those expected during the irradiation. The test showed that the condenser was capable of handling the design heat load and that the design procedure was sound.
Performance of evaporative condensers
Energy Technology Data Exchange (ETDEWEB)
Ettouney, Hisham M.; El-Dessouky, Hisham T.; Bouhamra, Walid; Al-Azmi, Bader
2001-07-01
Experimental investigation is conducted to study the performance of evaporative condensers/coolers. The analysis includes development of correlations for the external heat transfer coefficient and the system efficiency. The evaporative condenser includes two finned-tube heat exchangers. The system is designed to allow for operation of a single condenser, two condensers in parallel, and two condensers in series. The analysis is performed as a function of the water-to-air mass flow rate ratio (L/G) and the steam temperature. Also, comparison is made between the performance of the evaporative condenser and same device as an air-cooled condenser. Analysis of the collected data shows that the system efficiency increases at lower L/G ratios and higher steam temperatures. The system efficiency for various configurations for the evaporative condenser varies between 97% and 99%. Lower efficiencies are obtained for the air-cooled condenser, with values between 88% and 92%. The highest efficiency is found for the two condensers in series, followed by two condensers in parallel and then the single condenser. The parallel condenser configuration can handle a larger amount of inlet steam and can provide the required system efficiency and degree of subcooling. The correlation for the system efficiency gives a simple tool for preliminary system design. The correlation developed for the external heat transfer coefficient is found to be consistent with the available literature data. (Author)
Condenser performance monitoring and cleaning
International Nuclear Information System (INIS)
Walden, J.V.
1998-01-01
The main condenser at Ginna Station was retubed from admiralty brass to 316 stainless steel. A condenser performance monitoring spreadsheet was developed using EPRI guidelines after fouling was discovered. PEPSE computer models were used to determine the power loss and confirm the spreadsheet results. Cleaning of the condenser was performed using plastic scrubbers. Condenser performance improved dramatically following the cleaning. PEPSE, condenser spreadsheet performance, and actual observed plant data correlated well together. The fouling mechanism was determined to be a common lake bacteria and fungus growth which was combined with silt. Chlorination of the circulating water system at the allowable limits is keeping the biofouling under control
Energy Technology Data Exchange (ETDEWEB)
Liao, J.; Cao, L.; Ohkawa, K.; Frepoli, C. [LOCA Integrated Services I, Westinghouse Electric Company, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)
2012-07-01
The non-condensable gases condensation suppression model is important for a realistic LOCA safety analysis code. A condensation suppression model for direct contact condensation was previously developed by Westinghouse using first principles. The model is believed to be an accurate description of the direct contact condensation process in the presence of non-condensable gases. The Westinghouse condensation suppression model is further revised by applying a more physical model. The revised condensation suppression model is thus implemented into the WCOBRA/TRAC-TF2 LOCA safety evaluation code for both 3-D module (COBRA-TF) and 1-D module (TRAC-PF1). Parametric study using the revised Westinghouse condensation suppression model is conducted. Additionally, the performance of non-condensable gases condensation suppression model is examined in the ACHILLES (ISP-25) separate effects test and LOFT L2-5 (ISP-13) integral effects test. (authors)
Off gas condenser performance modelling
International Nuclear Information System (INIS)
Cains, P.W.; Hills, K.M.; Waring, S.; Pratchett, A.G.
1989-12-01
A suite of three programmes has been developed to model the ruthenium decontamination performance of a vitrification plant off-gas condenser. The stages of the model are: condensation of water vapour, NO x absorption in the condensate, RuO 4 absorption in the condensate. Juxtaposition of these stages gives a package that may be run on an IBM-compatible desktop PC. Experimental work indicates that the criterion [HNO 2 ] > 10 [RuO 4 ] used to determine RuO 4 destruction in solution is probably realistic under condenser conditions. Vapour pressures of RuO 4 over aqueous solutions at 70 o -90 o C are slightly lower than the values given by extrapolating the ln K p vs. T -1 relation derived from lower temperature data. (author)
The impact of fouling on performance evaluation of evaporative coolers and condensers
Energy Technology Data Exchange (ETDEWEB)
Qureshi, B.A.; Zubair, S.M. [King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia). Mechanical Engineering Dept.
2005-11-15
Fouling of evaporative cooler and condenser tubes is one of the most important factors affecting their thermal performance, which reduces effectiveness and heat transfer capability with time. In this paper, the experimental data on fouling reported in the literature are used to develop a fouling model for this class of heat exchangers. The model predicts the decrease in heat transfer rate with the growth of fouling. A detailed model of evaporative coolers and condensers, in conjunction with the fouling model, is used to study the effect of fouling on the thermal performance of these heat exchangers at different air inlet wet bulb temperatures. The results demonstrate that fouling of tubes reduces gains in performance resulting from decreasing values of air inlet wet bulb temperature. It is found that the maximum decrease in effectiveness due to fouling is about 55 and 78% for the evaporative coolers and condensers, respectively, investigated in this study. For the evaporative cooler, the value of process fluid outlet temperature T{sub p,out} varies by 0.66% only at the clean condition for the ambient wet bulb temperatures considered. (author)
International Nuclear Information System (INIS)
Lu, Wei; Meng, Zhuo; Sun, Yize; Zhong, Qianwen; Zhu, Helei
2016-01-01
Highlights: • Thermodynamic models for the compressor and evaporative condenser were developed. • An evaluation index was proposed to determine the optimal set point. • An algorithm was presented to compute the optimal set point. • Strategies for operating ammonia recycling system were proposed. - Abstract: Aiming at reducing the energy-consumption of ammonia recycling system, we presented floating condensing temperature control to maximize the coefficient of performance (COP) of the system. Firstly, thermodynamic models for the compressor and evaporative condenser were developed respectively. Then, an evaluation index and a solution scheme were proposed to determine the optimal set point of condensing temperature and the corresponding compressor speed. It is found that the system COP can be maximized by controlling the compressor speed to adjust the set point based on any given operating conditions. When the wet-bulb temperature is 22 °C, the system COP could be improved by 19.2–27.6% under floating condensing temperature control.
Evaluation of Advanced Models for PAFS Condensation Heat Transfer in SPACE Code
Energy Technology Data Exchange (ETDEWEB)
Bae, Byoung-Uhn; Kim, Seok; Park, Yu-Sun; Kang, Kyung Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ahn, Tae-Hwan; Yun, Byong-Jo [Pusan National University, Busan (Korea, Republic of)
2015-10-15
The PAFS (Passive Auxiliary Feedwater System) is operated by the natural circulation to remove the core decay heat through the PCHX (Passive Condensation Heat Exchanger) which is composed of the nearly horizontal tubes. For validation of the cooling and operational performance of the PAFS, PASCAL (PAFS Condensing Heat Removal Assessment Loop) facility was constructed and the condensation heat transfer and natural convection phenomena in the PAFS was experimentally investigated at KAERI (Korea Atomic Energy Research Institute). From the PASCAL experimental result, it was found that conventional system analysis code underestimated the condensation heat transfer. In this study, advanced condensation heat transfer models which can treat the heat transfer mechanisms with the different flow regimes in the nearly horizontal heat exchanger tube were analyzed. The models were implemented in a thermal hydraulic safety analysis code, SPACE (Safety and Performance Analysis Code for Nuclear Power Plant), and it was evaluated with the PASCAL experimental data. With an aim of enhancing the prediction capability for the condensation phenomenon inside the PCHX tube of the PAFS, advanced models for the condensation heat transfer were implemented into the wall condensation model of the SPACE code, so that the PASCAL experimental result was utilized to validate the condensation models. Calculation results showed that the improved model for the condensation heat transfer coefficient enhanced the prediction capability of the SPACE code. This result confirms that the mechanistic modeling for the film condensation in the steam phase and the convection in the condensate liquid contributed to enhance the prediction capability of the wall condensation model of the SPACE code and reduce conservatism in prediction of condensation heat transfer.
International Nuclear Information System (INIS)
Zhang, Shouzhen; Chen, Ben; Shu, Peng; Luo, Maji; Xie, Changjun; Quan, Shuhai; Tu, Zhengkai; Yu, Yi
2017-01-01
Highlights: • Anode Moisture condensing is introduced into a PEMFC stack. • Performance improves at high current density and high stack temperature after AMC. • MEA is dehydrated and poor performance occurs at low current density during AMC. - Abstract: Water management is an important issue for proton exchange membrane fuel cells. Back-diffusion of water from cathode to anode often occurs due to the differences in concentration and pressure during operation of fuel cell, resulting in the flooding and severe carbon corrosion in the cathode. Herein, we report a novel method of anode moisture condensing (AMC) in which a condenser is set at the outlet of the anode to cool down the anode moisture. With the help of AMC, liquid water is condensed from the moisture due to the variation of the saturated pressure of water vapor, which can accelerate the evaporating of the liquid water inside the anode and mitigate the probability of water flooding. A ten-cell stack with a condenser at the outlet of the anode is fabricated to systematically investigate the effects of the stack temperature and flow rate on the stack performance. The result shows that the PEMFC performance can be greatly improved at high current density and high operation temperature under the condition of AMC. The stack exhibits very similar performance before and after application of AMC below 500 mA cm"−"2, whereas the output power increases from 405 W to 436 W at 600 mA cm"−"2 at 65 °C. With further increase in operation temperature to 80 °C, the average voltage increases from 0.598 V to 0.641 V even at 500 mA cm"−"2. Moreover, the application of AMC can speed up the water evaporation, leading to the dehydration of the membrane and thus poor performance of PEMFC at low current density.
EVALUATION OF SOLVENTS EFFICIENCY IN CONDENSATE BANKING REMOVAL
CORREA, TOMAS; TIAB, DJEBBAR; RESTREPO, DORA PATRICIA
2009-01-01
This work describes experimental design and tests performed to simulate gas condensate reservoir conditions below dew point in the laboratory using three different compositions of synthetic gas condensate. Methanol, propanol and methylene chloride are the solvents used to remove the condensate banking and improve the gas effective permeability near to the wellbore. Solvents are injected in Berea sandstone rock with similar petrophysical properties in order to compare the efficiency at removin...
Condensed images for evaluating gastric motility patterns
Energy Technology Data Exchange (ETDEWEB)
Tatsch, K.; Schroettle, W.; Kirsch, C.-M. (Munich Univ. (Germany, F.R.). Dept. of Radiology)
1991-04-01
A condensed imaging technique was applied to gastric emptying studies to investigate (a) whether different types of motility disorders may be distinguished by characteristic image patterns and (b) whether the findings obtained provide additional information compared to standard quantitative measurements. Condensed images and quantitative data of gastric emptying were evaluated in 75 consecutive patients with normal function and various disorders such as peptic ulcer, postvagotomy, pyloric obstruction, dumping syndrome, gastoparesis etc. Condensed images were generated from a gastric region of interest. They display the distribution and behaviour of a radioactive test meal in a space-time matrix, whose horizontal and vertical dimensions are temporal and spatial, respectively. As shown in a series of representative examples condensed images disclose a variety of well-defined image patterns reflecting different pathophysiological mechanisms. This qualitative characterization of gastric emptying patterns provided in 34 of the 75 patients (45%) important new information compared to quantitative data. The application of condensed imaging techniques to gastric emptying studies (complementary to quantitative measurements) may, therefore, enhance the diagnostic value of scintigraphic techniques. (author).
Performance characterization of isolation condenser of SBWR
International Nuclear Information System (INIS)
Khan, H.J.; Rohatgi, U.S.
1992-01-01
A systematic study of the performance of the Isolation Condenser (IC) for a conceptual design of SBWR is presented. The objective of the IC is to passively remove heat and control the pressure variation in the Reactor Pressure Vessel (RPV). According to the observed trends, the IC cooling capacity and condensate flow can independently influence the ultimate performance of the IC. The transient pressure profile for the IC reaches different equilibrium values for each of the cases analyzed. The absolute magnitude of these values are a function of the cooling capacity and flow rates. With appropriate control of the liquid flow loss coefficients, the performance of the IC can be well predicted. Due to the lack of useful data, this study is limited to the numerical simulation of the IC
International Nuclear Information System (INIS)
Bandurski, Th.; Huggenberger, M.; Dreier, J.; Aubert, C.; Putz, F.; Gamble, R.E.; Yadigaroglu, G.
2001-01-01
Recently passive cooling systems have been designed for the long-term decay heat removal from the containment of Advanced Light Water Reactors. In particular, the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric European Simplified Boiling Water Reactor (ESBWR) has been tested in the large-scale PANDA facility. The PANDA tests achieved the dual objectives of improving confidence in the performance of the passive heat removal mechanisms underlying the design of the system, and extending the database available for containment analysis code qualification. The tests conducted subject the PCCS to a variety of conditions representing design-basis and beyond-design-basis accident conditions. These include operation in the presence of both heavier and lighter than steam non-condensable gases, as well as a variety of asymmetric and challenging start-up conditions. The present paper addresses the transient distribution of non-condensables in PANDA, and their effect on (passive) condenser performance. (author)
Energy Technology Data Exchange (ETDEWEB)
Bandurski, Th.; Huggenberger, M.; Dreier, J.; Aubert, C.; Putz, F.; Gamble, R.E.; Yadigaroglu, G
2001-03-01
Recently passive cooling systems have been designed for the long-term decay heat removal from the containment of Advanced Light Water Reactors. In particular, the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric European Simplified Boiling Water Reactor (ESBWR) has been tested in the large-scale PANDA facility. The PANDA tests achieved the dual objectives of improving confidence in the performance of the passive heat removal mechanisms underlying the design of the system, and extending the database available for containment analysis code qualification. The tests conducted subject the PCCS to a variety of conditions representing design-basis and beyond-design-basis accident conditions. These include operation in the presence of both heavier and lighter than steam non-condensable gases, as well as a variety of asymmetric and challenging start-up conditions. The present paper addresses the transient distribution of non-condensables in PANDA, and their effect on (passive) condenser performance. (author)
Development and Evaluation of a Sandia Cooler-based Refrigerator Condenser
Energy Technology Data Exchange (ETDEWEB)
Johnson, Terry A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kariya, Harumichi Arthur [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Leick, Michael T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zimmerman, Mark D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Li, Manjie [Univ. of Maryland, College Park, MD (United States); Du, Yilin [Univ. of Maryland, College Park, MD (United States); Lee, Hoseong [Univ. of Maryland, College Park, MD (United States); Hwang, Yunho [Univ. of Maryland, College Park, MD (United States); Radermacher, Reinhard [Univ. of Maryland, College Park, MD (United States)
2015-07-01
This report describes the first design of a refrigerator condenser using the Sandia Cooler, i.e. air - bearing supported rotating heat - sink impeller. The project included ba seline performance testing of a residential refrigerator, analysis and design development of a Sandia Cooler condenser assembly including a spiral channel baseplate, and performance measurement and validation of this condenser system as incorporated into the residential refrigerator. Comparable performance was achieved in a 60% smaller volume package. The improved modeling parameters can now be used to guide more optimized designs and more accurately predict performance.
Performance test of condensate polishing system for Qinshan Nuclear Power Plant
International Nuclear Information System (INIS)
You Zhaojin; Qian Shijun; Lu Ruiting
1995-11-01
The flow chart, resin performance and water quality specifications of the condensate polishing system for Qinshan Nuclear Power Plant (QNPP) are briefly described. The initial regeneration process and the following service of the condensate polishing system are introduced. And the ability to remove corrosion products and ionic impurities of the condensate polishing system are verified during start-up, normal power operation and condenser leakage of the plant. The result shows that the performance of condensate polishing system in QNPP can completely meet the design requirements. Especially during the start-up of the unit or the leakage of the condenser, despite the inlet water quality of the polishers is far worse than the specified standard, the outlet water quality is still controlled within the indexes. Finally, several existing problems, such as 'volume ratio between resins is not optimum' and 'the inert resin and anion resin can not be stratified completely', in the condensate polishing system are also discussed. (4 refs., 1 fig., 8 tabs.)
EXPERIMENTAL PERFORMANCE OF R134a AND R152a USING MICROCHANNEL CONDENSER
Bhatkar, V. W.
2018-01-01
An experimental performance study on vapour compression refrigeration system with R134a and drop in substitute R152a with aluminium microchannel condenser was carried out for condensation temperature of 48°C while evaporation temperature varied from -10 to 15°C. Refrigerant charge of R152a was reduced by 40% over R134a with the microchannel condenser. Performance parameters like work input to the compressor, coefficient of performance, refrigerating capacity, condenser capacity and the produc...
Energy Technology Data Exchange (ETDEWEB)
Hajidavalloo, E.; Eghtedari, H. [Mechanical Engineering Department, Shahid Chamran University, Golestan St., Ahvaz (Iran)
2010-08-15
Increasing the coefficient of performance of air conditioner with air-cooled condenser is a challenging problem especially in area with very hot weather conditions. Application of evaporatively cooled air condenser instead of air-cooled condenser is proposed in this paper as an efficient way to solve the problem. An evaporative cooler was built and coupled to the existing air-cooled condenser of a split-air-conditioner in order to measure its effect on the cycle performance under various ambient air temperatures up to 49 C. Experimental results show that application of evaporatively cooled air condenser has significant effect on the performance improvement of the cycle and the rate of improvement is increased as ambient air temperature increases. It is also found that by using evaporatively cooled air condenser in hot weather conditions, the power consumption can be reduced up to 20% and the coefficient of performance can be improved around 50%. More improvements can be expected if a more efficient evaporative cooler is used. (author)
Development of high performance condensers for thermal and nuclear power plants
International Nuclear Information System (INIS)
Okouchi, Isao; Takahashi, Sankichi; Tomita, Akira.
1980-01-01
As the trend toward the large capacity of thermal and nuclear power plants advances, condensers also become large, and from the viewpoint of energy saving in whole plants, the maintenance of high performance and reliability is strongly desired. Hitachi Ltd. responded to this demand, and repeated the basic investigation with a model condenser on the selection of condenser cooling tubes and their arrangement. As the result, balanced downflow type tube arrangement was developed, which enables smooth steam flow and the improvement of condenser performance by forming the intense flow of turbine exhaust from the upper part of tube nest downward and making the steam flow in the lower part of tube nest into radial form toward air ejecting port. This tube arrangement has been applied to actual machines, and the excellent results have been obtained. In particular, the improvement of the degree of vacuum due to the reduction of steam flow loss is advantageous for increasing the power output of turbines. Thereupon, based on the basic experiment with various models of tube arrangement and the consideration on the operational results of actual machines using this tube arrangement, the features of this technique are reported. The basic construction of tube arrangement, the steam flow in tube nest, the vacuum in condensers, the supercooling of condensate, and actual balanced downflow type condensers are described. (Kako, I.)
Condensation in complex geometries
International Nuclear Information System (INIS)
Lauro, F.
1975-01-01
A mathematical evaluation of the condensation exchange coefficient can only succeds for well specified cases: small upright or inclined plates, horizontal tubes, small height vertical tubes. Among the main hypotheses accounted for this mathematical development in the case of the condensate, a laminar flow and uniform surface temperature are always considered. In practice certain shapes of surfaces significantly increase the heat transfer during the vapor condensation on a surface wet by the condensate. Such surfaces are rough surfaces such as the condensate is submitted to surface tension effects, negligeable for plane or large curvature surfaces, and the nature of the material may play an important role (temperature gradients). Results from tests on tubes with special shapes, performed in France or out of France, are given [fr
Gas condensate reservoir performance : part 1 : fluid characterization
Energy Technology Data Exchange (ETDEWEB)
Thomas, F.B.; Bennion, D.B. [Hycal Energy Research Laboratories Ltd., Calgary, AB (Canada); Andersen, G. [ChevronTexaco, Calgary, AB (Canada)
2006-07-01
Phase behaviour in gas condensate reservoirs is sensitive to changes in pressure and temperature, which can lead to significant errors in fluid characterization. The challenging task of characterizing in situ fluids in gas condensate reservoirs was discussed with reference to the errors that occur as a result of the complex coupling between phase behavior and geology. This paper presented techniques for reservoir sampling and characterization and proposed methods for minimizing errors. Errors are often made in the classification of dew point systems because engineering criteria does not accurately represent the phase behavior of the reservoir. For example, the fluid of a certain condensate yield may be categorized as a wet gas rather than a retrograde condensate fluid. It was noted that the liquid yield does not dictate whether the fluid is condensate or wet gas, but rather where the reservoir temperature is situated in the pressure temperature phase loop. In order to proceed with a viable field development plan and optimization, the reservoir fluid must be understood. Given that gas productivity decreases with liquid drop out in the near wellbore region, capillary pressure plays a significant role in retrograde reservoirs. It was noted that well understood parameters will lead to a better assessment of the amount of hydrocarbon in place, the rate at which the resource can be produced and optimization strategies as the reservoir matures. It was concluded that multi-rate sampling is the best method to use in sampling fluids since the liquid yield changes as a function of rate. Although bottom-hole sampling in gas condensate reservoirs may be problematic, it should always be performed to address any concerns for liquid-solid separation. Produced fluids typically reveal a specific signature that informs the operator of in situ properties. This paper presented examples that pertain to wet versus retrograde condensate behavior and the presence of an oil zone. The
Real-time monitoring energy efficiency and performance degradation of condensing boilers
International Nuclear Information System (INIS)
Baldi, Simone; Quang, Thuan Le; Holub, Ondrej; Endel, Petr
2017-01-01
Highlights: • Fully-fledged set of fault detection and diagnosis tools for condensing boilers. • Detection of boiler performance degradation in condensing and noncondensing mode. • Virtual sensing for estimation of water mass flow rate. • Optimal Kalman detection of actuator and sensor faults. • Structural properties for detection and isolation of faults. - Abstract: Condensing boilers achieve higher efficiency than traditional boilers by using waste heat in flue gases to preheat cold return water entering the boiler. Water vapor produced during combustion is condensed into liquid form, thus recovering its latent heat of vaporization, leading to around 10–12% increased efficiency. Many countries have encouraged the use of condensing boilers with financial incentives. It is thus important to develop software tools to assess the correct functioning of the boiler and eventually detect problems. Current monitoring tools are based on boiler static maps and on large sets of historical data, and are unable to assess timely loss of performance due to degradation of the efficiency curve or water leakages. This work develops a set of fault detection and diagnosis tools for dynamic energy efficiency monitoring and assessment in condensing boilers, i.e. performance degradation and faults can be detected using real-time measurements: this real-time feature is particularly relevant because of the limited amount of data that can be stored by state-of-the-art building energy management systems. The monitoring tools are organized as follows: a bimodal parameter estimator to detect deviations of the efficiency of the boiler from nominal values in both condensing and noncondensing mode; a virtual sensor for the estimation of the water mass flow rate; filters to detect actuator and sensor faults, possibly due to control and sensing problems. Most importantly, structural properties for detection and isolation of actuators and sensing faults are given: these properties are
International Nuclear Information System (INIS)
Andrieux, M.B.
1984-01-01
Characteristics of the condenser cooling waters of various French 900 MW nuclear power plants. Design and description of various types of condensers: condensers feeded directly with river water, condensers feeded by cooling towers, condensers feeded with sea water of brackish water. Presentation of the main problems encountered with the brass bundles (ammoniacal corrosion, erosion of the peripheral tubes, vibrations of the tubes), with the titanium bundles, with the tubular plates, the tubes-tubular plates assemblies, the coatings of the condenser water chamber (sea water), the vapor by-pass and with the air inlet. Analysis of the in service performances such as condensation pressure, oxygen content and availability [fr
Heat transfer performance of condenser tubes in an MSF desalination system
International Nuclear Information System (INIS)
Galal, T.; Kalendar, A.; Al Saftawi, A.; Zedan, M.
2010-01-01
The present research examines the amount of condensed fresh water off the outer-side surface of heat exchangers in an MSF system. The quantitative modeling of condensed water on the outer surface of comparable tubes, enhanced and plain, in a simulated MSF technique is investigated. An adapted simulation design on a test-rig facility, accounting for the condenser tubing in actual industrial desalination plate-form, is used with corrugated and smooth aluminum-brass material tubes 1100mm long and 23mm bore. A single phase flow of authentic brine water that typifies real fouling is utilized to simulate the actual environmental life of a multi-stage flashing desalination system, with coolant flow velocity 0.1 m/s in the two delineated types of condenser tubing. It is demonstrated that the condensate water amount from the specified enhanced tube is about 1.22 times the condensate water amount from the smooth tube, adaptive for 140 running hours under deliberated constrains. The topic covers a comparative analysis of thermal performance. Comparing results with fresh water confirm the effect of fouling on significantly lowering the value of the overall heat transfer coefficient versus time. Fouling resistance R f is reported with the critical coolant flow speed of 0.1 m/s. Comparison between the fouling resistance for both smooth and corrugated tubes versus time is performed. The fouling thermal resistance of the corrugated tube is 0.56 of the fouling thermal resistance of the smooth tube after140 running hours of the experiment are concluded. Overall, in the case of real brine, results prove that heat performance for the corrugated tube is superior to the plain tube over the studied time period (140 hrs) for the chosen range of flow speeds
Evaluation of fission product removal by an ice-condenser containment
International Nuclear Information System (INIS)
Kubis, K.
1977-01-01
Studies have been restricted to removal of iodine, a fission product significant with regard to radiation protection. Results referring to the absorption of molecular iodine in an ice bed have been obtained from model experiments. These data were the basis of evaluating iodine removal in a containment with ice condenser. Removal has been determined by use of computational models. The ice condenser reduces the iodine amount released by one order of magnitude. (author)
Statistical evaluation of steam condensation loads in pressure suppression pool, (1)
International Nuclear Information System (INIS)
Kukita, Yutaka; Takeshita, Isao; Namatame, Ken; Shiba, Masayoshi; Kato, Masami; Moriya, Kumiaki.
1981-10-01
The LOCA steam condensation loads in the BWR pressure suppression pool was evaluated with use of the test data obtained in the first eight tests of the JAERI Full-Scale Mark II CRT Program. Through this evaluation, finite desynchronization between the vent pressures during the chugging and the condensation oscillation phases was identified and quantified. The characteristics of the pressure oscillation propagation through the vent pipe and in the pool water, the fluid-structure-interaction (FSI) effects on the pool pressure loads, and the characteristics of the vent lateral loads were also investigated. (author)
Proceedings: Condenser technology conference
International Nuclear Information System (INIS)
Tsou, J.L.; Mussalli, Y.G.
1991-08-01
Seam surface condenser and associated systems performance strongly affects availability and heat rate in nuclear and fossil power plants. Thirty-six papers presented at a 1990 conference discuss research results, industry experience, and case histories of condenser problems and solutions. This report contains papers on life extension, performance improvement, corrosion and failure analysis, fouling prevention, and recommendation for future R ampersand D. The information represents recent work on condenser problems and solutions to improve the procurement, operation, and maintenance functions of power plant personnel. Several key points follow: A nuclear and a fossil power plant report show that replacing titanium tube bundles improves condenser availability and performance. One paper reports 10 years of experience with enhanced heat transfer tubes in utility condensers. The newly developed enhanced condenser tubes could further improve condensing heat transfer. A new resistance summation method improves the accuracy of condenser performance prediction, especially for stainless steel and titanium tubed condensers. Several papers describe improved condenser fouling monitoring techniques, including a review of zebra mussel issues
Traditionally, pervaporation systems have been operated using a total condenser to deliver the final permeate liquid product. Over the past two years, we have investigated the use of a condensation process called "dephlegmation" to enhance the separation performance of pervapora...
Evaluation of condensate filtration technologies in fossil plants
Energy Technology Data Exchange (ETDEWEB)
D' Angelo, Philip J. [JoDan Technologies Ltd., Glen Mills, PA (United States)
2009-09-15
Long-term protection of electric power generating station boilers depends upon the quality of their feedwater chemistry with respect to the transport and deposition of corrosion products to the boilers from various corrosion sources in the plant's condensate and feedwater cycle. It is in the utility's best interests to expand their programs to include ways to reduce the transport of corrosion products, especially those that occur during plant start-ups. Condensate filtration is a strategy employed by some utilities with demonstrable results in minimizing corrosion product transport and achieving a return on their investment. This paper provides a comparative review of available condensate filtration technologies as well as performance data from fossil plants with the new large diameter high flow filtration systems. Additionally, the paper identifies critical parameters to consider before installation as well as the necessity for agreement between utilities and suppliers on common filtration terminology definitions, to insure an ''apple-to-apple'' basis when comparing a system or technology from more than one supplier. (orig.)
International Nuclear Information System (INIS)
Moore, J.; Grimes, R.; Walsh, E.; O'Donovan, A.
2014-01-01
This paper aims at developing a novel air-cooled condenser for concentrated solar power plants. The condenser offers two significant advantages over the existing state-of-the-art. Firstly, it can be installed in a modular format where pre-assembled condenser modules reduce installation costs. Secondly, instead of using large fixed speed fans, smaller speed controlled fans are incorporated into the individual modules. This facility allows the operating point of the condenser to change and continuously maximise plant efficiency. A thorough experimental analysis was performed on a number of prototype condenser designs. This analysis investigated the validly and accuracy of correlations from literature in predicting the thermal and aerodynamic characteristics of different designs. These measurements were used to develop a thermodynamic model to predict the performance of a 50 MW CSP (Concentrated Solar Power) plant with various condenser designs installed. In order to compare different designs with respect to the specific plant capital cost, a techno-economic analysis was performed which identified the optimum size of each condenser. The results show that a single row plate finned tube design, a four row, and a two row circular finned tube design are all similar in terms of their techno-economic performance and offer significant savings over other designs. - Highlights: • A novel air cooled condenser for CSP (Concentrated Solar Power) applications is proposed. • A thorough experimental analysis of various condenser designs was performed. • Heat transfer and flow friction correlations validated for fan generated air flow. • A thermodynamic model to calculate CSP plant output is presented. • Results show the proposed condenser design can continually optimise plant output
International Nuclear Information System (INIS)
Kim, Sook Kwan; Sim, Suk Ku; Park, Ju Yeop; Seol, Kwang Won; Ryu, Yong Ho
2011-01-01
The effect of non-condensable gas on the performance of PRHRS (Passive Residual Heat Removal System) of the Small and Medium Reactor(SMR) was evaluated during a loss of flow event. Since the TMI accident in 1979, the passive systems have been considered in the advanced reactors as a feature of design improvement because the passive system simplifies the system and thus increases the reliability of the system. The Westinghouse received the design certification from the USNRC for the AP600 and AP1000 passive type pressurized water reactors. The APR+ under development by KEPCO considers the use of PAFS (Passive Auxiliary Feedwater System). And the PRHRS is adopted as a passive secondary heat removal system for the SMART (System-integrated Modular Advanced ReacTor)
Heat transfer performance during condensation of R-134a inside helicoidal tubes
International Nuclear Information System (INIS)
Al-Hajeri, M.H.; Koluib, A.M.; Mosaad, M.; Al-Kulaib, S.
2007-01-01
This paper reports an experimental investigation of condensation heat transfer and pressure drop of an ozone friendly refrigerant, R-134a, inside a helical tube for climatic conditioning of hot regions. This study concerns the condensation of R-134a flowing through annular helical tubes with different operating refrigerant saturated temperatures. The average pressure drop is measured and compared with data from relevant literature. The measurements of R-134a were performed on mass flow flux ranges from 50 to 680 kg/m 2 s. The study provides experimental data that could be used for the design and development of more efficient condensers for refrigeration and air conditioning (A/C) systems working with the same refrigerant
Millstone 3 condensate dissolved gas monitoring
International Nuclear Information System (INIS)
Burns, T.F.; Grondahl, E.E.; Snyder, D.T.
1988-01-01
Condensate dissolved oxygen problems at Millstone Point Unit 3 (MP3) were investigated using the Dissolved Gas Monitoring System developed by Radiological and Chemical Technology, Inc. under EPRI sponsorship. Argon was injected into the turbine exhaust basket tips to perform a dissolved gas transport analysis and determine steam jet air ejector gas removal efficiency. The operating configuration of the steam jet air ejector system was varied to determine the effect on gas removal efficiency. Following circulating water chlorination, the gas removal efficiency was determined to evaluate the effect of condenser tube fouling on steam jet air ejector performance
Possibility of removing condensate and scattered oil from gas-condensate field during bed flooding
Energy Technology Data Exchange (ETDEWEB)
Belkina, N.A.; Yagubov, M.S.
1984-01-01
The problem is set of evaluating the possible removal from the bed of scattered oil and condensate during flooding of the bed. For this purpose, an experimental study was made of the displacement by water from the porous medium of the oil and condensate saturating it. The obtained experimental results permit evaluation of the possible removal from the gas-condensate bed of scattered oil and condensate during flooding of the bed.
Preventing freezing of condensate inside tubes of air cooled condenser
International Nuclear Information System (INIS)
Joo, Jeong A; Hwang, In Hwan; Lee, Dong Hwan; Cho, Young Il
2012-01-01
An air cooled condenser is a device that is used for converting steam into condensate by using ambient air. The air cooled condenser is prone to suffer from a serious explosion when the condensate inside the tubes of a heat exchanger is frozen; in particular, tubes can break during winter. This is primarily due to the structural problem of the tube outlet of an existing conventional air cooled condenser system, which causes the backflow of residual steam and noncondensable gases. To solve the backflow problem in such condensers, such a system was simulated and a new system was designed and evaluated in this study. The experimental results using the simulated condenser showed the occurrence of freezing because of the backflow inside the tube. On the other hand, no backflow and freezing occurred in the advanced new condenser, and efficient heat exchange occurred
Evaluation of gastric motility by Fourier analysis of condensed images
Energy Technology Data Exchange (ETDEWEB)
Linke, R.; Muenzing, W.; Hahn, K.; Tatsch, K. [Dept. of Nuclear Medicine, Univ. of Munich, Munich (Germany)
2000-10-01
In this study Fourier analysis was applied to condensed images of gastric emptying with the aim of evaluating the amplitude and frequency of gastric contractions as well as gastric emptying in patients with various well-defined disorders. In 15 controls, 65 patients with progressive systemic sclerosis (PSS), 41 patients with diabetes mellitus type I (DM), 12 patients with pyloric stenosis and 9 patients who had undergone gastric surgery, gastric emptying was determined after ingestion of a semi-solid test meal. In addition, condensed images were generated to evaluate the amplitude and frequency of gastric contractions by means of Fourier analysis. In PSS and DM patients, gastric emptying and contraction amplitudes were significantly reduced (P<0.01). Patients with pyloric stenosis displayed regular peristalsis but significantly delayed emptying (P<0.01). Patients who had undergone gastric surgery showed normal or rapid gastric emptying associated with decreased amplitudes (P<0.01). The frequency of gastric contractions in the patient groups was not different from that in controls. This study showed Fourier analysis of condensed images to be a rapid and feasible approach for the evaluation of gastric contractions. Depending on the underlying disorder, gastric emptying and peristalsis showed both corresponding and discrepant findings. Data on gastric contractions provided additional information compared with results obtained by conventional emptying studies. Therefore, both parameters should be routinely assessed to further improve characterisation of gastric dysfunction by scintigraphy. (orig.)
Evaluation of gastric motility by Fourier analysis of condensed images
International Nuclear Information System (INIS)
Linke, R.; Muenzing, W.; Hahn, K.; Tatsch, K.
2000-01-01
In this study Fourier analysis was applied to condensed images of gastric emptying with the aim of evaluating the amplitude and frequency of gastric contractions as well as gastric emptying in patients with various well-defined disorders. In 15 controls, 65 patients with progressive systemic sclerosis (PSS), 41 patients with diabetes mellitus type I (DM), 12 patients with pyloric stenosis and 9 patients who had undergone gastric surgery, gastric emptying was determined after ingestion of a semi-solid test meal. In addition, condensed images were generated to evaluate the amplitude and frequency of gastric contractions by means of Fourier analysis. In PSS and DM patients, gastric emptying and contraction amplitudes were significantly reduced (P<0.01). Patients with pyloric stenosis displayed regular peristalsis but significantly delayed emptying (P<0.01). Patients who had undergone gastric surgery showed normal or rapid gastric emptying associated with decreased amplitudes (P<0.01). The frequency of gastric contractions in the patient groups was not different from that in controls. This study showed Fourier analysis of condensed images to be a rapid and feasible approach for the evaluation of gastric contractions. Depending on the underlying disorder, gastric emptying and peristalsis showed both corresponding and discrepant findings. Data on gastric contractions provided additional information compared with results obtained by conventional emptying studies. Therefore, both parameters should be routinely assessed to further improve characterisation of gastric dysfunction by scintigraphy. (orig.)
International Nuclear Information System (INIS)
Ding Xudong; Cai Wenjian; Jia Lei; Wen Changyun; Zhang Guiqing
2009-01-01
In this paper, a simple, yet accurate hybrid modeling technique for condensers is presented. The method starts with fundamental physical principles but captures only few key operational characteristic parameters to predict the system performances. The advantages of the methods lie that linear or non-linear least-squares methods can be directly used to determine no more than four key operational characteristic parameters in the model, which can significantly reduce the computational burden. The developed model is verified with the experimental data taken from a pilot system. The testing results confirm that the proposed model can predict accurately the performance of the real-time operating condenser with the maximum error of less than ±10%. The model technique proposed will have wide applications not only in condenser operating optimization, but also in performance assessment and fault detection and diagnosis.
Effect of Mixed Working Fluid Composition on Binary Cycle Condenser Heat Transfer Coefficients
Energy Technology Data Exchange (ETDEWEB)
Dan Wendt; Greg Mines
2011-10-01
Effect of Mixed Working Fluid Composition on Binary Cycle Condenser Heat Transfer Coefficients Dan Wendt, Greg Mines Idaho National Laboratory The use of mixed working fluids in binary power plants can provide significant increases in plant performance, provided the heat exchangers are designed to take advantage of these fluids non-isothermal phase changes. In the 1980's testing was conducted at DOE's Heat Cycle Research Facility (HCRF) where mixtures of different compositions were vaporized at supercritical pressures and then condensed. This testing had focused on using the data collected to verify that Heat Transfer Research Incorporated (HTRI) codes were suitable for the design of heat exchangers that could be used with mixtures. The HCRF data includes mixture compositions varying from 0% to 40% isopentane and condenser tube orientations of 15{sup o}, 60{sup o}, and 90{sup o} from horizontal. Testing was performed over a range of working fluid and cooling fluid conditions. Though the condenser used in this testing was water cooled, the working fluid condensation occurred on the tube-side of the heat exchanger. This tube-side condensation is analogous to that in an air-cooled condenser. Tube-side condensing heat transfer coefficient information gleaned from the HCRF testing is used in this study to assess the suitability of air-cooled condenser designs for use with mixtures. Results of an air-cooled binary plant process model performed with Aspen Plus indicate that that the optimal mixture composition (producing the maximum net power for the scenario considered) is within the range of compositions for which data exist. The HCRF data is used to assess the impact of composition, tube orientation, and process parameters on the condensing heat transfer coefficients. The sensitivity of the condensing coefficients to these factors is evaluated and the suitability of air-cooled condenser designs with mixtures is assessed. This paper summarizes the evaluation
Part load performance of air-cooled centrifugal chillers with variable speed condenser fan control
Energy Technology Data Exchange (ETDEWEB)
Yu, F.W.; Chan, K.T. [Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)
2007-11-15
Air-cooled centrifugal chillers are commonly used in commercial buildings but their performance analysis is lacking. This paper investigates the part load performance of the chillers via a thermodynamic model. The model was validated using a wide range of operating data from an existing chiller with specific settings of outdoor temperature and condensing pressure in controlling the condensing temperature. The validated model was developed specifically to ascertain the maximum coefficient of performance of chiller (COP) together with the strategy for optimizing the condensing temperature under various operating conditions. It is found that the highest COP occurs at a part load ratio (PLR) of 0.71-0.84, depending on the outdoor temperature and the control of condensing temperature, rather than at full load. Yet the chillers operating at such part load conditions will cause extra energy used for the early staging of chilled water pumps. To minimize the overall chiller plant energy consumption, it is still preferable to implement chiller sequencing based on the full load condition than on the aforementioned PLRs. The results of this paper present criteria for implementing low-energy strategies for operating air-cooled chillers satisfying a given building cooling load profile. (author)
Thu, Kyaw
2013-01-01
Energy or heat recovery schemes are keys for the performance improvement of any heat-activated cycles such as the absorption and adsorption cycles. We present two innovative heat recovery schemes between the condensing and evaporating units of an adsorption desalination (AD) cycle. By recovering the latent heat of condenser and dumping it into the evaporative process of the evaporator, it elevates the evaporating temperature and hence the adsorption pressure seen by the adsorbent. From isotherms, this has an effect of increasing the vapour uptake. In the proposed configurations, one approach is simply to have a run-about water circuit between the condenser and the evaporator and a pump is used to achieve the water circulation. This run-around circuit is a practical method for retrofitting purposes. The second method is targeted towards a new AD cycle where an encapsulated condenser-evaporator unit is employed. The heat transfer between the condensing and evaporative vapour is almost immediate and the processes occur in a fully integrated vessel, thereby minimizing the heat transfer resistances of heat exchangers. © 2013 Desalination Publications.
Energy Technology Data Exchange (ETDEWEB)
Lee, Yeon Gun; Kim, Sin [Jeju National Univ., Jeju (Korea, Republic of); Jerng, Dong Wook [Chung Ang Univ., Seoul (Korea, Republic of)
2013-10-15
In this study, the effect of the transverse curvature on the condensation HTC on a vertical tube in the presence of air is preliminarily investigated by using the analysis of boundary layer for free convective heat transfer. The results indicate that the heat transfer performance can be enhanced as the outer diameter of condenser tubes is small. To confirm this curvature effect, an experimental program to obtain the condensation heat transfer data for various values of tube diameter is indispensable. Currently, by a joint research project of Jeju National University and Chung-Ang University, a condensation test facility is being designed and constructed to acquire the condensation HTC data as shown in Fig. 3. From a series of experiment on a single vertical tube, the effects of not only the tube diameter but the inclination, the existence of fins and the local velocity of a bulk mixture by natural circulation will be evaluated precisely. An empirical correlation for the condensation heat transfer of a steam-air mixture will also be developed for design optimization and performance evaluation of the PCCS. The Passive Containment Cooling System (PCCS) provides passive means to remove the decay heat and protect the integrity of the containment during severe accidents. Korea, in which all the NPPs employ the concrete containment, may adopt a PCCS using internal condensers. In the event of the loss-of-coolant accident (LOCA), steam released from the reactor coolant system is mixed with air inside the containment and condensed on the outer surface of inclined condenser tubes. It is noted that, among previous theoretical and empirical models for condensation on outer wall in the presence of non-condensable gas, no one took into account the effect of a tube diameter. Though the condensation heat transfer coefficient may vary with transverse curvature of condenser tubes, such a curvature effect has not been reported so far. In this study, a preliminary analysis is conducted
International Nuclear Information System (INIS)
Lee, Yeon Gun; Kim, Sin; Jerng, Dong Wook
2013-01-01
In this study, the effect of the transverse curvature on the condensation HTC on a vertical tube in the presence of air is preliminarily investigated by using the analysis of boundary layer for free convective heat transfer. The results indicate that the heat transfer performance can be enhanced as the outer diameter of condenser tubes is small. To confirm this curvature effect, an experimental program to obtain the condensation heat transfer data for various values of tube diameter is indispensable. Currently, by a joint research project of Jeju National University and Chung-Ang University, a condensation test facility is being designed and constructed to acquire the condensation HTC data as shown in Fig. 3. From a series of experiment on a single vertical tube, the effects of not only the tube diameter but the inclination, the existence of fins and the local velocity of a bulk mixture by natural circulation will be evaluated precisely. An empirical correlation for the condensation heat transfer of a steam-air mixture will also be developed for design optimization and performance evaluation of the PCCS. The Passive Containment Cooling System (PCCS) provides passive means to remove the decay heat and protect the integrity of the containment during severe accidents. Korea, in which all the NPPs employ the concrete containment, may adopt a PCCS using internal condensers. In the event of the loss-of-coolant accident (LOCA), steam released from the reactor coolant system is mixed with air inside the containment and condensed on the outer surface of inclined condenser tubes. It is noted that, among previous theoretical and empirical models for condensation on outer wall in the presence of non-condensable gas, no one took into account the effect of a tube diameter. Though the condensation heat transfer coefficient may vary with transverse curvature of condenser tubes, such a curvature effect has not been reported so far. In this study, a preliminary analysis is conducted
Analytical study of condensation heat transfer on titanium tube with super-hydrophobic surface
Energy Technology Data Exchange (ETDEWEB)
Ji, Dae Yun; Park, Hyun Gyu; Lee, Kwon Yeong [Handong Global University, Pohang (Korea, Republic of)
2016-05-15
There are many nuclear or fossil power plants which occupy more than 85% among entire power plants in the world. These plants release heat through condenser into nature. The condenser is an important component for cooling the working fluid after the turbine. Its performance is related with material and size of its tubes. To have good performance or to reduce condenser size, it is important to increase condensation heat transfer coefficient on condenser tubes. Ma et al. executed heat transfer experiment in dropwise condensation with non-condensable gas, and studied how the amount of air and pressure difference affect condensation heat transfer coefficient. The more non-condensable gas existed, the condensation heat transfer coefficient was decreased. Shen et al. studied condensation heat transfer at horizontal bundle tubes. Several variables such as coolant velocity, saturated pressure, and surface conditions were studied. As a result, surface modified brass tube and stainless tube showed higher condensation heat transfer coefficient as much as 1.3 and 1.4 times comparing with their bare tubes, in 70 kPa vacuum condition respectively. Rausch et al. studied dropwise condensation on ion-implanted titanium surface. Experimental study is performed to evaluate the performance of surface modified titanium tube in vacuum state. SAM coating is used to make super-hydrophobic surface of titanium tube. Preliminary analysis were performed considering filmwise and dropwise condensations, respectively. Experiment facility is almost prepared and the test result will be shown soon.
Low pressure lithium condensation
International Nuclear Information System (INIS)
Wadkins, R.P.; Oh, C.H.
1985-01-01
A low pressure experiment to evaluate the laminar film condensation coefficients of lithium was conducted. Some thirty-six different heat transfer tests were made at system pressures ranging from 1.3 to 26 Pa. Boiled lithium was condensed on the inside of a 7.6-cm (ID), 409 stainless-steel pipe. Condensed lithium was allowed to reflux back to the pool boiling region below the condensing section. Fourteen chromel/alumel thermocouples were attached in various regions of the condensing section. The thermocouples were initially calibrated with errors of less than one degree Celsius
International Nuclear Information System (INIS)
Liu, Qiang; Duan, Yuanyuan; Yang, Zhen
2014-01-01
Highlights: • A condensation pressure determination method for ORC with zeotropic mixture is given. • The effects of condensation temperature glide on the ORC performance are analyzed. • Mixture mole fractions for the maximum power output of a geothermal ORC are identified. • The biomass ORC performance with part of the latent heat transferred in the IHE is analyzed. - Abstract: The organic Rankine cycle (ORC) has been widely used to convert low-grade ( 2 M) selected as working fluids for the cogenerative ORC driven by the biomass energy. Two optimal working fluid mole fractions maximize the cycle efficiency, exergy efficiency and net power output for cooling water temperature increases less than the maximum condensation temperature glide, while the highest net power output appears at the higher mole fraction of the more volatile component for the geothermal ORC when the condensation temperature glide of the working fluid mixture matches the cooling water temperature increase. Higher condensation temperature glides result in large thermal loss to the heat sink and exergy destruction in the condenser. There is only one optimal working fluid mole fraction that maximizes the thermal efficiency, exergy efficiency and net power output when the cooling water temperature increase is greater than the condensation temperature glide
Using helical compressors for coke gas condensation
Energy Technology Data Exchange (ETDEWEB)
Privalov, V E; Rezunenko, Yu I; Lelyanov, N V; Zarnitzkii, G Eh; Gordienko, A A; Derebenko, I F; Venzhega, A G; Leonov, N P; Gorokhov, N N
1982-08-01
Coke oven gas compression is discussed. Presently used multilevel piston compressors are criticized. The paper recommends using helical machines which combine advantages of using volume condensing compressors and compact high-efficiency centrifugal machines. Two kinds of helical compressors are evaluated: dry and oil-filled; their productivities and coke oven gas chemical composition are analyzed. Experiments using helical compressors were undertaken at the Yasinovskii plant. Flowsheet of the installation is shown. Performance results are given in a table. For all operating conditions content of insolubles in oil compounds is found to be lower than the acceptable value (0.08%). Compressor productivity measurements with variable manifold pressure are evaluated. Figures obtained show that efficient condensation of raw coke oven gas is possible. Increasing oil-filled compressor productivity is recommended by decreasing amount of oil injected and simultaneously increasing rotation speed. The dry helical compressor with water seal is found to be most promising for raw coke oven gas condensation. (10 refs.)
Energy Technology Data Exchange (ETDEWEB)
Bharathan, D.; Parsons, B.K.; Althof, J.A.
1988-10-01
The objective of the reported work was to develop analytical methods for evaluating the design and performance of advanced high-performance heat exchangers for use in open-cycle thermal energy conversion (OC-OTEC) systems. This report describes the progress made on validating a one-dimensional, steady-state analytical computer of fresh water experiments. The condenser model represents the state of the art in direct-contact heat exchange for condensation for OC-OTEC applications. This is expected to provide a basis for optimizing OC-OTEC plant configurations. Using the model, we examined two condenser geometries, a cocurrent and a countercurrent configuration. This report provides detailed validation results for important condenser parameters for cocurrent and countercurrent flows. Based on the comparisons and uncertainty overlap between the experimental data and predictions, the model is shown to predict critical condenser performance parameters with an uncertainty acceptable for general engineering design and performance evaluations. 33 refs., 69 figs., 38 tabs.
International Nuclear Information System (INIS)
Wang Shuangfeng; Chen Jinjian; Hu Yanxin; Zhang Wei
2011-01-01
Flat plate heat pipes (FPHPs) are one of the available technologies to deal with the high density electronic cooling problem due to their high thermal conductivity, reliability, and low weight penalty. A series of experiments were performed to investigate the effect of evaporation and condensation length on thermal performance of flat plate heat pipes. In the experiments, the FPHP had heat transfer length of 255 mm and width of 25 mm, and pure water was used as the working fluid. The results show that comparing to vapor chamber, the FPHP could realize long-distance heat transfer; comparing to the traditional heat pipe, the FPHP has large area contact with heat sources; the thermal resistance decreased and the heat transfer limit increased with the increase of evaporation section length; the FPHP would dry out at a lower heating power with the increase of condensation section length, which indicated that the heat transfer limit decreased, but the evaporator temperature also decreased; when the condensation section length approached to evaporation section length, the FPHP had a better thermal performance. - Highlights: → A strip sintered FPHP is proposed and tested. → The total heat transfer length reaches 255 mm → The efficiency of heat transport reaches 94.4%. → When the condensation section length approached to evaporation section length, the FPHP has better overall performance.
A model for the performance of a vertical tube condenser in the presence of noncondensable gases
Energy Technology Data Exchange (ETDEWEB)
Guentay, A.D.S.
1995-09-01
Some proposed vertical tube condensers are designed to operate at high noncondensable fractions, which warrants a simple model to predict their performance. Models developed thus far are usually non self-contained as they require the specification of the wall temperature to predict the local condensation rate. The present model attempts to fill this gap by addressing the secondary side heat transfer as well. Starting with momentum balance which includes the effect of interfacial shear stress, a Nusselt-type algebraic equation is derived for the film thickness as a function of flow and geometry parameters. The heat and mass transfer analogy relations are then invoked to deduce the condensation rate of steam onto the tube wall. Lastly, the heat transfer to the secondary side is modelled to include cooling by forced, free or mixed convection flows. The model is used for parametric simulations to determine the impact on the condenser performance of important factors such as the inlet gas fraction, the mixture inlet flowrate, the total pressure, and the molecular weight of the noncondensable gas. The model performed simulations of some experiments with pure steam and air-steam mixtures flowing down a vertical tube. The model predicts the data quite well.
Condensation coefficient of water in a weak condensation state
International Nuclear Information System (INIS)
Kobayashi, Kazumichi; Watanabe, Shunsuke; Yamano, Daigo; Yano, Takeru; Fujikawa, Shigeo
2008-01-01
The condensation coefficient of water at a vapor-liquid interface is determined by combining shock tube experiments and numerical simulations of the Gaussian-BGK Boltzmann equation. The time evolution in thickness of a liquid film, which is formed on the shock tube endwall behind the shock wave reflected at the endwall, is measured with an optical interferometer consisting of the physical beam and the reference one. The reference beam is utilized to eliminate systematic noises from the physical beam. The growth rate of the film is evaluated from the measured time evolution and it is incorporated into the kinetic boundary condition for the Boltzmann equation. From a numerical simulation using the boundary condition, the condensation coefficient of water is uniquely deduced. The results show that, in a condition of weak condensation near a vapor-liquid equilibrium state, the condensation coefficient of water is almost equal to the evaporation coefficient estimated by molecular dynamics simulations near a vapor-liquid equilibrium state and it decreases as the system becomes a nonequilibrium state. The condensation coefficient of water is nearly identical with that of methanol [Mikami, S., Kobayashi, K., Ota, T., Fujikawa, S., Yano, T., Ichijo, M., 2006. Molecular gas dynamics approaches to interfacial phenomena accompanied with condensation. Exp. Therm. Fluid Sci. 30, 795-800].
Condensation coefficient of water in a weak condensation state
Kobayashi, Kazumichi; Watanabe, Shunsuke; Yamano, Daigo; Yano, Takeru; Fujikawa, Shigeo
2008-07-01
The condensation coefficient of water at a vapor-liquid interface is determined by combining shock tube experiments and numerical simulations of the Gaussian-BGK Boltzmann equation. The time evolution in thickness of a liquid film, which is formed on the shock tube endwall behind the shock wave reflected at the endwall, is measured with an optical interferometer consisting of the physical beam and the reference one. The reference beam is utilized to eliminate systematic noises from the physical beam. The growth rate of the film is evaluated from the measured time evolution and it is incorporated into the kinetic boundary condition for the Boltzmann equation. From a numerical simulation using the boundary condition, the condensation coefficient of water is uniquely deduced. The results show that, in a condition of weak condensation near a vapor-liquid equilibrium state, the condensation coefficient of water is almost equal to the evaporation coefficient estimated by molecular dynamics simulations near a vapor-liquid equilibrium state and it decreases as the system becomes a nonequilibrium state. The condensation coefficient of water is nearly identical with that of methanol [Mikami, S., Kobayashi, K., Ota, T., Fujikawa, S., Yano, T., Ichijo, M., 2006. Molecular gas dynamics approaches to interfacial phenomena accompanied with condensation. Exp. Therm. Fluid Sci. 30, 795-800].
Improved condenser design and condenser-fan operation for air-cooled chillers
International Nuclear Information System (INIS)
Yu, F.W.; Chan, K.T.
2006-01-01
Air-cooled chillers traditionally operate under head pressure control via staging constant-speed condenser fans. This causes a significant drop in their coefficient of performance (COP) at part load or low outdoor temperatures. This paper describes how the COP of these chillers can be improved by a new condenser design, using evaporative pre-coolers and variable-speed fans. A thermodynamic model for an air-cooled screw-chiller was developed, within which the condenser component considers empirical equations showing the effectiveness of an evaporative pre-cooler in lowering the outdoor temperature in the heat-rejection process. The condenser component also contains an algorithm to determine the number and speed of the condenser fans staged at any given set point of condensing temperature. It is found that the chiller's COP can be maximized by adjusting the set point based on any given chiller load and wet-bulb temperature of the outdoor air. A 5.6-113.4% increase in chiller COP can be achieved from the new condenser design and condenser fan operation. This provides important insights into how to develop more energy-efficient air-cooled chillers
Thu, Kyaw; Kim, Youngdeuk; Myat, Aung; Chakraborty, Anutosh; Ng, K. C.
2013-01-01
Energy or heat recovery schemes are keys for the performance improvement of any heat-activated cycles such as the absorption and adsorption cycles. We present two innovative heat recovery schemes between the condensing and evaporating units
Amrat Kumar Dhamneya; S.P.S. Rajput; Alok Singh
2018-01-01
The nanoparticle is used in chillers for increasing system performance. The increasing concentration of nanoparticles (TiO2) in refrigerant increases the performances of the system due decreasing compressor work done and enhance heat transfer rate. For hot and dry climate condition, performances of air-cooled condenser minimize, and C. O. P. decreases extensively in chillers due to heat transfer rate decreases in the condenser. In the condenser, nano-refrigerants are not cool at the desired l...
Solution procedure and performance evaluation for a water–LiBr absorption refrigeration machine
International Nuclear Information System (INIS)
Wonchala, Jason; Hazledine, Maxwell; Goni Boulama, Kiari
2014-01-01
The water–lithium bromide absorption cooling machine was investigated theoretically in this paper. A detailed solution procedure was proposed and validated. A parametric study was conducted over the entire admissible ranges of the desorber, condenser, absorber and evaporator temperatures. The performance of the machine was evaluated based on the circulation ratio which is a measure of the system size and cost, the first law coefficient of performance and the second law exergy efficiency. The circulation ratio and the coefficient of performance were seen to improve as the temperature of the heat source increased, while the second law performance deteriorated. The same qualitative responses were obtained when the temperature of the refrigerated environment was increased. On the other hand, simultaneously raising the condenser and absorber temperatures was seen to result in a severe deterioration of both the circulation ratio and first law coefficient of performance, while the second law performance indicator improved significantly. The influence of the difference between the condenser and absorber exit temperatures, as well as that of the internal recovery heat exchanger on the different performance indicators was also calculated and discussed. - Highlights: • Analysis of a water–LiBr absorption machine, including detailed solution procedure. • Performance assessed using first and second law considerations, as well as flow ratio. • Effects of heat source and refrigerated environment temperatures on the performance. • Effects of the difference between condenser and absorber temperatures. • Effects of internal heat exchanger efficiency on overall cooling machine performance
Directory of Open Access Journals (Sweden)
Amrat Kumar Dhamneya
2018-03-01
Full Text Available The nanoparticle is used in chillers for increasing system performance. The increasing concentration of nanoparticles (TiO2 in refrigerant increases the performances of the system due decreasing compressor work done and enhance heat transfer rate. For hot and dry climate condition, performances of air-cooled condenser minimize, and C. O. P. decreases extensively in chillers due to heat transfer rate decreases in the condenser. In the condenser, nano-refrigerants are not cool at the desired level, and the system was faulty. These drawbacks of the nano-particles mixed refrigerator have promoted the research and improving heat rejection rate in the condenser. In this article, vapour compression refrigeration system coupled with evaporative cooling pad, and nano-refrigerant, for improving the performance of the system in hot & dry weather is proposed and compared experimentally. Combined evaporative cooling system and ice plant test rig have been proposed for the appropriate heat rejection offered in the condenser due to a faulty system run at high pressure. The experimental investigations revealed that the performance characteristics of the evaporatively-cooled condenser are significantly enhanced. Maximum C.O.P. increases by about 51% in the hot and dry climate condition than the normal system.
Simple Simulations of DNA Condensation
Energy Technology Data Exchange (ETDEWEB)
STEVENS,MARK J.
2000-07-12
Molecular dynamics simulations of a simple, bead-spring model of semiflexible polyelectrolytes such as DNA are performed. All charges are explicitly treated. Starting from extended, noncondensed conformations, condensed structures form in the simulations with tetravalent or trivalent counterions. No condensates form or are stable for divalent counterions. The mechanism by which condensates form is described. Briefly, condensation occurs because electrostatic interactions dominate entropy, and the favored Coulombic structure is a charge ordered state. Condensation is a generic phenomena and occurs for a variety of polyelectrolyte parameters. Toroids and rods are the condensate structures. Toroids form preferentially when the molecular stiffness is sufficiently strong.
International Nuclear Information System (INIS)
Cheng, Wen-long; Ding, Miao; Yuan, Xu-dong; Han, Bing-Chuan
2017-01-01
Highlights: • A novel refrigerator with both HSC and CSE is proposed. • The operational characteristics of novel refrigerator is analyzed. • The comparison of CSE, HSC and DES refrigerators is analyzed. • DES refrigerator has a largest off-time to on-time ratio of 4.3. • DES refrigerator has the best electrical energy saving performance (32%). - Abstract: The heat transfer performances of evaporators and condensers significantly affect the efficiency of household refrigerators. For enhancing heat transfer of the condensers and evaporators, a novel dual energy storage (DES) refrigerator with both heat storage condenser (HSC) and cold storage evaporator (CSE) is proposed. The performance comparison of three kinds of energy storage refrigerators: HSC refrigerator, CSE refrigerator and DES refrigerator is analyzed by establishing dynamic simulation models. According to the simulation results, the DES refrigerator combines the advantage of HSC refrigerator and CSE refrigerator, it has more balanced operational cycle and higher evaporation pressure and temperature. The DES refrigerator shows a best energy saving performance among the three energy storage refrigerators with largest off-time to on-time ratio of 4.3 and the electrical consumption saving can reach 32%, which is greater than the sum (28%) of the other two kinds of energy storage refrigerators.
Liang, Qing; Li, Yi; Wang, Qiuliang
2018-01-01
A cryogenic oscillating heat pipe (OHP) made of a bended copper capillary tube is manufactured. The lengths of the condenser section, adiabatic section and evaporator section are 100, 280 and 100 mm, respectively. Neon is used as the working fluid. Effects of liquid filling ratio and condenser temperature on the thermal performance of the OHP are studied. A correlation based on the available experimental data sets is proposed to predict the thermal performance of the neon cryogenic OHP with different filling ratios and condenser temperature. Compared with the experimental data, the average standard deviation of the correlation is about 15.0%, and approximately 92.4% of deviations are within ±30%.
Two experiments were conducted to evaluate the effects of feeding condensed distillers solubles (DS) and crude glycerin alone or in combination on performance of finishing beef cattle and in vitro fermentation. In both experiments, dietary treatments consisted of a steam flaked corn (SFC) based diet...
Performance of casting aluminum-silicon alloy condensing heating exchanger for gas-fired boiler
Cao, Weixue; Liu, Fengguo; You, Xue-yi
2018-01-01
Condensing gas boilers are widely used due to their high heat efficiency, which comes from their ability to use the recoverable sensible heat and latent heat in flue gas. The condensed water of the boiler exhaust has strong corrosion effect on the heat exchanger, which restricts the further application of the condensing gas boiler. In recent years, a casting aluminum-silicon alloy (CASA), which boasts good anti-corrosion properties, has been introduced to condensing hot water boilers. In this paper, the heat transfer performance, CO and NOx emission concentrations and CASA corrosion resistance of a heat exchanger are studied by an efficiency bench test of the gas-fired boiler. The experimental results are compared with heat exchangers produced by Honeywell and Beka. The results show that the excess air coefficient has a significant effect on the heat efficiency and CO and NOx emission of the CASA water heater. When the excess air coefficient of the CASA gas boiler is 1.3, the CO and NOx emission concentration of the flue gas satisfies the design requirements, and the heat efficiency of water heater is 90.8%. In addition, with the increase of heat load rate, the heat transfer coefficient of the heat exchanger and the heat efficiency of the water heater are increased. However, when the heat load rate is at 90%, the NOx emission in the exhaust gas is the highest. Furthermore, when the temperature of flue gas is below 57 °C, the condensation of water vapor occurs, and the pH of condensed water is in the 2.5 5.5 range. The study shows that CASA water heater has good corrosion resistance and a high heat efficiency of 88%. Compared with the heat exchangers produced by Honeywell and Beka, there is still much work to do in optimizing and improving the water heater.
The performance of a mobile air conditioning system with a water cooled condenser
International Nuclear Information System (INIS)
Di Battista, Davide; Cipollone, Roberto
2015-01-01
Vehicle technological evolution lived, in recent years, a strong acceleration due to the increased awareness of environmental issues related to pollutants and climate altering emissions. This resulted in a series of international regulations on automotive sector which put technical challenges that must consider the engine and the vehicle as a global system, in order to improve the overall efficiency of the system. The air conditioning system of the cabin, for instance, is the one of the most important auxiliaries in a vehicle and requires significant powers. Its performances can be significantly improved if it is integrated within the engine cooling circuit, eventually modified with more temperature levels.In this paper, the Authors present a mathematical model of the A/C system, starting from its single components: compressors, condenser, flush valve and evaporator and a comparison between different refrigerant fluid. In particular, it is introduced the opportunity to have an A/C condenser cooled by a water circuit instead of the external air linked to the vehicle speed, as in the actual traditional configuration. The A/C condenser, in fact, could be housed on a low temperature water circuit, reducing the condensing temperature of the refrigeration cycle with a considerable efficiency increase. (paper)
The performance of a mobile air conditioning system with a water cooled condenser
Di Battista, Davide; Cipollone, Roberto
2015-11-01
Vehicle technological evolution lived, in recent years, a strong acceleration due to the increased awareness of environmental issues related to pollutants and climate altering emissions. This resulted in a series of international regulations on automotive sector which put technical challenges that must consider the engine and the vehicle as a global system, in order to improve the overall efficiency of the system. The air conditioning system of the cabin, for instance, is the one of the most important auxiliaries in a vehicle and requires significant powers. Its performances can be significantly improved if it is integrated within the engine cooling circuit, eventually modified with more temperature levels. In this paper, the Authors present a mathematical model of the A/C system, starting from its single components: compressors, condenser, flush valve and evaporator and a comparison between different refrigerant fluid. In particular, it is introduced the opportunity to have an A/C condenser cooled by a water circuit instead of the external air linked to the vehicle speed, as in the actual traditional configuration. The A/C condenser, in fact, could be housed on a low temperature water circuit, reducing the condensing temperature of the refrigeration cycle with a considerable efficiency increase.
Energy Technology Data Exchange (ETDEWEB)
Kim, Myoung Jun; Lee, Hee Joon [Kookmin University, Seoul (Korea, Republic of); Moon, Joo Hyung; Bae, Youngmin; Kim, Young-In [KAERI, Daejeon (Korea, Republic of)
2015-05-15
In the event of a 'loss of coolant accident'(LOCA) and a non-LOCA, the secondary passive cooling system would be activated to cool the steam in a condensing heat exchanger that is immersed in an emergency cooldown tank (ECT). Currently, the capacities of these ECTs are designed to be sufficient to remove the sensible and residual heat from the reactor coolant system for 72 hours after the occurrence of an accident. After the operation of a conventional passive cooling system for an extended period, however, the water level falls as a result of the evaporation from the ECT, as steam is emitted from the open top of the tank. Therefore, the tank should be refilled regularly from an auxiliary water supply system when the system is used for more than 72 hours. Otherwise, the system would fail to dissipate heat from the condensing heat exchanger due to the loss of the cooling water. Ultimately, the functionality of the passive cooling system would be seriously compromised. As a passive means of overcoming the water depletion in the tank, Kim et al. applied for a Korean patent covering the concept of a long-term passive cooling system for an ECT even after 72 hours. This study presents transient performance of ECT with installing air-cooled condensing heat exchanger under decay heat load. The cooling capacity of an air-cooled condensing heat exchanger was evaluated to determine its practicality.
Directory of Open Access Journals (Sweden)
Yeong-Jun Jang
2017-11-01
Full Text Available This paper presents an experimental investigation on the enhancement of the heat transfer rate of steam condensation on the external surfaces of a vertical tube with annular fins. A cylindrical condenser tube, which is 40 mm in outer diameter and 1000 mm in length, with annular disks of uniform cross-sectional area is fabricated in the manner of ensuring perfect contact between the base surface and fins. A total of 13 annular fins of 80 mm diameter were installed along the tube height in order to increase the effective heat transfer area by 85%. Through a series of condensation tests for the air-steam mixture under natural convection conditions, the heat transfer data was measured in the pressure range of between 2 and 5 bar, and the air mass fraction from 0.3 to 0.7. The rates of heat transfer of the finned tube are compared to those that are measured on a bare tube to demonstrate the enhanced performance by extended surfaces. In addition, based on the experimental results and the characteristics of steam condensation, the applicability of finned tubes to a large condenser system with a bundle layout is evaluated.
Directory of Open Access Journals (Sweden)
Tzong-Shing Lee
2012-03-01
Full Text Available This study constructed a parameter analysis for improving the energy performance of air-cooled water chillers by altering the angle configuration of the condenser coils. The mathematical models for energy and exergy analyses of the individual components and overall system of air-cooled water chillers are presented. This study investigated the potential enhancement of performance efficiency in air-cooled chillers and the energy conversion efficiency of each component, in order to determine how the angle configuration of condenser coils influences chiller performance. This study found that the overall performance of an air-cooled chiller could be improved by approximately 3.4%, and the total irreversibility could be reduced by approximately 2.7%. With each 1% increase in average wind speed over the condenser coils, the overall performance of an air‑cooled chiller was found to be enhanced by approximately 0.43%, and its total irreversibility was reduced by approximately 0.35%. The results of this study can be effectively applied to air-cooled condenser units, and can provide an important basis of reference for developing and enhancing the energy efficiency of air-cooled chillers.
Limitations of the condensed history method for low-energy electrons
International Nuclear Information System (INIS)
Martin, W.R.; Ballinger, C.T.; Rathkopf, J.A.
1991-01-01
A systematic evaluation of the conventional, condensed history electron transport methodology has been performed through comparisons with more accurate single-scatter Monte Carlo calculations. These comparisons highlight the inaccuracies associated with the condensed history method and indicate its range of validity. The condensed history method is used in codes such as MCNP4, SANDYL, ETRAN, ITS, and EGS and requires a number of restrictive assumptions about the scattering characteristics to make tractable the analytical solution to the infinite-medium transport equation. Distributions describing electron characteristics after multiple collisions (multiscatter distributions) are constructed from such solutions and serve as the heart of the condensed history codes. A two-level approach is taken to quantify the errors inherent in condensed history. First, conventional condensed history multiscattering distributions in energy and angle are compared directly with analogous distributions generated with a single-scatter Monte Carlo code. This recently developed code directly simulates individual electron interactions. Second, the conventional distributions are replaced in the condensed history code by distributions constructed via a single-scatter Monte Carlo simulation
Energy Technology Data Exchange (ETDEWEB)
Abdoelatef, M. Gomaa; Rezk, Osama; Lee, YonKwan [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)
2015-10-15
• Perception of nuclear power as a convenient, economically competitive and viable source of energy which, if introduced in the country, would not only complement the traditional energy sources, but would also promote technological development and serve as an incentive for social and economic progress. In this paper we will introduce APR-1400 as the most likely selected reactor type for 1st Egyptian Nuclear Power Plant. Then we will study the optimized APR-1400 condenser performance based on El-Dabaa site conditions. As the climate conditions, especially the seawater temperatures (intake for the cooling system) having a direct effects on the condenser performance and the overall NPP Efficiency, we studied the seawater temperature change based on EL-Dabaa site conditions and it's feedback on the proposed APR-1400 condenser performance and the NPP efficiency. All of the calculations and analysis had been executed by using KINGS NPA by applying EL-Dabaa seawater temperature variations for the 2 types of APR-1400 Condensers (Shinkori, south Korea and Barakah, UAE), and the main findings were as follow: For the APR-1400 condensers (Shinkori and Barakah) performance • The average difference all over the year for saturation temperature, cooling water outlet temperature, and condenser pressure are 0.135 .deg. C, .05785 .deg. C, and 0.3948 mHgA respectively. This shows that the Barakah condenser performance is not significantly better than the shinkori condenser performance based on EL-Dabaa Conditions, especially if we considered the cost difference between the two condensers designs. For APR-1400 NPPs (Shinkori and Barakah) net efficiency • The average difference all over the year for the power productions and net efficiency are 1.4791 MWe and .00037 %, respectively.
International Nuclear Information System (INIS)
Kubota, Shintaro; Izumo, Sari; Usui, Hideo; Kawagoshi, Hiroshi; Koda, Yuya; Nanko, Takashi
2014-07-01
Japan Atomic Energy Agency (JAEA) has been developing the PRODIA code which supports to make decommissioning plan and has been preparing evaluation formulas. Manpower needs for the dismantling of the condenser that had conducted from 2010 to 2012 was analyzed and compared with existing evaluation formulas. Applicability of evaluation formulas for a large scale reactor facility was confirmed in dismantling of the heat insulating materials and reliability of unit productivity factor was improved. The evaluation formula of work for clearance was made in dismantling of pipes and supports. Unit productivity factor of dismantling of feed water heaters which is applicable for a large scale reactor facility was derived. For derivation of unit productivity factor, statistically meaningful data was provided from the dismantling of the condenser. Manpower needs for dismantling of the condenser has positive correlation to the weight of equipment and can be described in linear expression. Reliability of each unit productivity factor will be improved with accumulating actual dismantling data in future. (author)
Steam generators, turbines, and condensers. Volume six
International Nuclear Information System (INIS)
Anon.
1986-01-01
Volume six covers steam generators (How steam is generated, steam generation in a PWR, vertical U-tube steam generators, once-through steam generators, how much steam do steam generators make?), turbines (basic turbine principles, impulse turbines, reaction turbines, turbine stages, turbine arrangements, turbine steam flow, steam admission to turbines, turbine seals and supports, turbine oil system, generators), and condensers (need for condensers, basic condenser principles, condenser arrangements, heat transfer in condensers, air removal from condensers, circulating water system, heat loss to the circulating water system, factors affecting condenser performance, condenser auxiliaries)
EPA's Environmental Technology Verification Program has tested New Condensator Inc.'s Condensator Diesel Engine Retrofit Crankcase Ventilation System. Brake specific fuel consumption (BSFC), the ratio of engine fuel consumption to the engine power output, was evaluated for engine...
International Nuclear Information System (INIS)
Chien, T.H.; Domanus, H.M.; Sha, W.T.
1993-02-01
The COMMIX-PPC computer pregrain is an extended and improved version of earlier COMMIX codes and is specifically designed for evaluating the thermal performance of power plant condensers. The COMMIX codes are general-purpose computer programs for the analysis of fluid flow and heat transfer in complex Industrial systems. In COMMIX-PPC, two major features have been added to previously published COMMIX codes. One feature is the incorporation of one-dimensional equations of conservation of mass, momentum, and energy on the tube stile and the proper accounting for the thermal interaction between shell and tube side through the porous-medium approach. The other added feature is the extension of the three-dimensional conservation equations for shell-side flow to treat the flow of a multicomponent medium. COMMIX-PPC is designed to perform steady-state and transient. Three-dimensional analysis of fluid flow with heat transfer tn a power plant condenser. However, the code is designed in a generalized fashion so that, with some modification, it can be used to analyze processes in any heat exchanger or other single-phase engineering applications. Volume I (Equations and Numerics) of this report describes in detail the basic equations, formulation, solution procedures, and models for a phenomena. Volume II (User's Guide and Manual) contains the input instruction, flow charts, sample problems, and descriptions of available options and boundary conditions
Integral Reactor Containment Condensation Model and Experimental Validation
Energy Technology Data Exchange (ETDEWEB)
Wu, Qiao [Oregon State Univ., Corvallis, OR (United States); Corradini, Michael [Univ. of Wisconsin, Madison, WI (United States)
2016-05-02
This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). In the three years of investigation duration, following the original proposal, the planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). A film flow model was developed for the scaling analysis, and the results suggest that the 1/3 scaled test facility covers large portion of laminar film flow, leading to a lower average heat transfer coefficient comparing to the prototypic value. Although it is conservative in reactor safety analysis, the significant reduction of heat transfer coefficient (50%) could under estimate the prototypic condensation heat transfer rate, resulting in inaccurate prediction of the decay heat removal capability. Further investigation is thus needed to quantify the scaling distortion for safety analysis code validation. Experimental investigations were performed in the existing MASLWR test facility at OrST with minor modifications. A total of 13 containment condensation tests were conducted for pressure
Titanium application to power plant condensers
International Nuclear Information System (INIS)
Itoh, H.
1987-01-01
Recently, the growth of operating performance and construction plan of titanium-tubed condensers in thermal and unclear power plants has been very impressive. High-quality, thinner welded titanium tubes used for cooling tubes, matching design specifications of condensers, have been stably supplied through mass production. It now can be said that various technical problems for titanium-tubed condensers have been solved, but data on operating performance in large-scale commercial plants are still scarce, and site-by-site information needs be exchanged more frequently and on a larger scale. Projects to replace existing condenser cooling tubes with those of corrosion-resistant titanium have been actively furthered, with the only remaining barrier to full employment being cost effectiveness. It is hoped that condenser and tube manufacturers will conduct more joint value analyses
Condensation model for the ESBWR passive condensers
International Nuclear Information System (INIS)
Revankar, S. T.; Zhou, W.; Wolf, B.; Oh, S.
2012-01-01
In the General Electric's Economic simplified boiling water reactor (GE-ESBWR) the passive containment cooling system (PCCS) plays a major role in containment pressure control in case of an loss of coolant accident. The PCCS condenser must be able to remove sufficient energy from the reactor containment to prevent containment from exceeding its design pressure following a design basis accident. There are three PCCS condensation modes depending on the containment pressurization due to coolant discharge; complete condensation, cyclic venting and flow through mode. The present work reviews the models and presents model predictive capability along with comparison with existing data from separate effects test. The condensation models in thermal hydraulics code RELAP5 are also assessed to examine its application to various flow modes of condensation. The default model in the code predicts complete condensation well, and basically is Nusselt solution. The UCB model predicts through flow well. None of condensation model in RELAP5 predict complete condensation, cyclic venting, and through flow condensation consistently. New condensation correlations are given that accurately predict all three modes of PCCS condensation. (authors)
Effect of flow velocity on the process of air-steam condensation in a vertical tube condenser
Havlík, Jan; Dlouhý, Tomáš
2018-06-01
This article describes the influence of flow velocity on the condensation process in a vertical tube. For the case of condensation in a vertical tube condenser, both the pure steam condensation process and the air-steam mixture condensation process were theoretically and experimentally analyzed. The influence of steam flow velocity on the value of the heat transfer coefficient during the condensation process was evaluated. For the condensation of pure steam, the influence of flow velocity on the value of the heat transfer coefficient begins to be seen at higher speeds, conversely, this effect is negligible at low values of steam velocity. On the other hand, for the air-steam mixture condensation, the influence of flow velocity must always be taken into account. The flow velocity affects the water vapor diffusion process through non-condensing air. The presence of air significantly reduces the value of the heat transfer coefficient. This drop in the heat transfer coefficient is significant at low velocities; on the contrary, the decrease is relatively small at high values of the velocity.
Parametric analysis of a solar still with inverted V-shaped glass condenser
Directory of Open Access Journals (Sweden)
Rubio Eduardo
2015-01-01
Full Text Available A parametric analysis of a solar still with an inverted V-shaped glass condenser is presented. Results are based on a new mathematical model obtained from a lumped-parameter analysis of the still, with an approach that makes each glass plate of the condensing system sensitive to orientation and depicts its thermal differences. Numerical computations are made to evaluate productivity and temperature differences between the condensing plates as a function of condenser orientation, extinction coefficient and thickness. From this study it was found a significant influence of incident solar radiation on the thermal performance of each condensing plate. Large extinction coefficients and thick glass plates increase absorption losses that result in an appreciable temperature difference. An extinction coefficient of 40 m-1 produces a temperature difference of 2.5°C between both condensers. A glass thickness of 10 mm may increase this temperature difference up to 3.5°C. With respect to the production, due to the still orientation, a difference of 8.7% was found for the condensing plates facing an east-west direction. The proposed model is able to reproduce the temperature and distillate production differences that arise between both condensers in good agreement with experimental data. The overall performance of the still, studied with this new approach, was also in accordance with the widely used traditional models for solar distillation. In addition, the condensing plates parameters of the still can be used to force a differential heating such that for the whole day the temperature of one condensing plate is always higher.
Evaluation of ion exchange resin performance in Kuosheng nuclear power plant
International Nuclear Information System (INIS)
Wen, T.J.; Chen Huang, T.; Liu, W.C.; Liu, T.C.; Shen, S.C.
2004-01-01
Different types and brands of bead and powdered ion exchange resin have been widely used in condensate and reactor water clean-up system in Boiling Water Reactors (BWRs). The importance of primary coolant quality control has been well recognized. Recently, some measures both in promoting the conductivity of reactor water and minimizing iron crud of feed-water have been recommended by the Institute of Nuclear Energy Research. The variation of water quality between the condensate and reactor water is closely related with the performance of condensate polisher and precoat condition. In order to ensure optimization of water chemistry quality in reactor system, historical water chemistry data have been reviewed and evaluated. The most probable causes of exceeding the chemistry limits and guidelines should be identified and some reasonable corrective actions have been documented as a reference for promoting the water quality and run length extending in the plant normal operation. (author)
Energy Technology Data Exchange (ETDEWEB)
Im, Sung-Gu; Lee, Sang-Hyup; Ji, Dae-Yun; Park, Hyun-Gyu; Lee, Kwon-Yeong [Handong Global University, Pohang (Korea, Republic of)
2016-10-15
Condensation occurs when the temperature of a steam is reduced below its saturation temperature. There exist two forms of condensation on cooling surface: dropwise, and film condensations. Usually, dropwise condensation has a better heat transfer performance than film condensation, but it has limit of short period. Ma et al. executed heat transfer experiment in dropwise condensation with non-condensable gas, and studied how the amount of air and pressure difference affect condensation heat transfer coefficient. The more non-condensable gas exist, the condensation heat transfer coefficient is decreased. As a result, surface modified brass tube and stainless tube showed higher condensation heat transfer coefficient as much as 1.3 and 1.4 times comparing with their bare tubes in 70 kPa vacuum condition respectively. Most of power plants use sea water as coolant, so the surface of metal tubes could be corroded by the coolant. We had researched an experimental study related to condensation heat transfer on surface modified titanium tube. Our experimental facility was designed to show how two kinds of tube's heat transfer performances are different in a same condition. We changed the range of saturation pressure and coolant flow rate to observe tube's performance change. When saturation pressure and coolant flow rate increase, overall heat transfer coefficients were increased. When residue of non-condensable gases was decreased, the overall heat transfer coefficients were increased. S.A.M. coated tube's overall heat transfer coefficients were lower than those of bare tube, because the droplets didn't have a tendency of frequently falling down.
Impact of element-level static condensation on iterative solver performance
Pardo, D.
2015-10-02
This paper provides theoretical estimates that quantify and clarify the savings associated to the use of element-level static condensation as a first step of an iterative solver. These estimates are verified numerically. The numerical evidence shows that static condensation at the element level is beneficial for higher-order methods. For lower-order methods or when the number of iterations required for convergence is low, the setup cost of the elimination as well as its implementation may offset the benefits obtained during the iteration process. However, as the iteration count (e.g., above 50) or the polynomial order (e.g., above cubics) grows, the benefits of element-level static condensation are significant.
International Nuclear Information System (INIS)
Jeon, Seong Su; Lee, Byung Chul; Park, Ju Yeop; Seul, Kwang Won
2011-01-01
In South Korea, advanced power reactor plus (APR+), as a Korean specific reactor, is currently under development for the export strategy. In order to raise competitiveness of the APR+ in the world market, it is necessary to develop the original technology for the improved technology, economics, and safety features. For this purpose, a passive auxiliary feedwater system (PAFS) was adopted as an improved safety design concept of APR+: and then there have been many efforts to develop the PAFS. According to PAFS design concept, PAFS can completely replace the auxiliary feedwater system. When the design basis accident, in which feedwater is unavailable, occurs, the PAFS can remove the residual heat in the core and then prevent the core damage. In the PAFS with the horizontal type heat exchanger, two-phase natural circulation, condensation heat transfer in tube, boiling heat transfer in pool, natural convection in pool, etc. are considered as very important thermalhydraulic phenomena (see Fig. 1). Compared with the vertical heat exchanger from these phenomena, the major difference of the horizontal heat exchanger is the condensation heat transfer phenomena in the tube side. There have been many efforts to understand the condensation heat transfer with in the presence of NC gas in tube but most researches focused on the condensation heat transfer in vertical tube. Therefore the details of the condensation heat transfer in the presence of NC gas in horizontal condenser tubes are not well understood. In order to develop the safety evaluation system for APR+ PAFS, it is required to evaluate the capability and applicability of the MARS-KS code for modeling the condensation heat transfer in the horizontal tube with NC gas because many heat transfer correlations in MARS-KS are known to have much uncertainty. In particular, there is no reliable model for the condensation phenomena in horizontal tube with NC gas. In order to assess the MARS-KS code results and identify the
Energy Technology Data Exchange (ETDEWEB)
Malet, J., E-mail: jeanne.malet@irsn.fr [Institut de Radioprotection et de Surete Nucleaire (IRSN), PSN-RES, SCA, BP 68, 91192 Gif-sur-Yvette (France); Porcheron, E.; Dumay, F.; Vendel, J. [Institut de Radioprotection et de Surete Nucleaire (IRSN), PSN-RES, SCA, BP 68, 91192 Gif-sur-Yvette (France)
2012-12-15
Highlights: Black-Right-Pointing-Pointer Steam condensation on walls has been investigated in the TOSQAN vessel. Black-Right-Pointing-Pointer Experiments on 7 different tests have been performed. Black-Right-Pointing-Pointer Different steam injections and wall temperatures are used. Black-Right-Pointing-Pointer Simulations are performed in 2D using the TONUS code. Black-Right-Pointing-Pointer Code-experiments comparisons at many different locations show a good agreement. - Abstract: During the course of a severe Pressurized Water Reactor accident, pressurization of the containment occurs and hydrogen can be produced by the reactor core oxidation and distributed in the containment according to convection flows and wall condensation. Filmwise wall condensation in the presence of non-condensable gases is a subject of many interests and extensive studies have been performed in the past. Some empirical correlations have demonstrated their limit for extrapolation under different thermal-hydraulic conditions and at different geometries/scales. The French Institute for Radiological Protection and Nuclear Safety (IRSN) has developed a numerical tool and an experimental facility in order to investigate free convection flows in the presence of condensation. The objective of this paper is to present numerical results obtained on different wall condensation tests in 7 m{sup 3} volume vessel (TOSQAN facility), and to compare them with the experimental ones. Over eight tests are considered here, and code-experiment comparison is performed on many different locations, giving an extensive insight of the code assessment for air-steam mixture flows involving wall condensation in the presence of non-condensable gases.
Experimental verification of a condenser with liquid–vapor separation in an air conditioning system
International Nuclear Information System (INIS)
Chen, Xueqing; Chen, Ying; Deng, Lisheng; Mo, Songping; Zhang, Haiyan
2013-01-01
Three liquid–vapor separation condensers (LSC) were tested to evaluate their ability to automatically separate the liquid and vapor during condensation. Each was used in a split-type air conditioner to investigate the performance. The performance of the LSC system having the greatest cooling capacity and energy efficiency ratio (EER) was then compared with that of the system having a baseline fin-and-tube condenser for various ambient temperatures from 29 °C to 43 °C. The results showed that both the cooling capacity and EER of the two systems were almost the same at the three standard conditions in the Chinese standard GB/T 7725-2004, with the LSC having just 67% of the heat transfer area of the baseline condenser. In addition, the LSC system was charged with only 80% of the refrigerant in the baseline system. -- Highlights: ► We tested three liquid–vapor separation condensers in an air conditioning system. ► The best system had the most uniform wall temperature and the smallest pressure drop. ► The LSC system performance with only 67% condenser area was as good as the baseline system. ► LSC system operations are compared for various outdoor temperatures
Effects of non-condensable gas on the condensation of steam
International Nuclear Information System (INIS)
Jackson, J.D.; An, P.; Reinert, A.; Ahmadinejad, M.
2000-01-01
The experimental work reported here was undertaken with the aim of extending the database currently available on the condensation of steam in the presence of non-condensable gases and thereby improving the empirical input to thermal-hydraulic codes which might be used for design and safety assessment of advanced water-cooled nuclear reactors. Heat was removed from flowing mixtures of steam and air in a test section by means of a water-cooled condensing plate. The test facility constructed for the study incorporates a degassing unit which supplies water to a boiler. This delivers steam steadily to a mixing chamber where it joins with a flow of preheated air. The mixture of steam and air is supplied to the bottom of a cylindrical test section in which it flows upwards over a double sided condensing plate which can be vertical, inclined or horizontal, The rate at which heat is removed by cooling water flowing through internal passages in the plate can de determined calorimetrically knowing the flow rate of the water and its temperature rise. After commissioning experiments had shown that reliable measurements of condensation heat transfer rate could be made using the test facility, a programme of development work followed in the course of which three different designs of condensing plate were evaluated in turn. The version eventually used in the main programme of experiments which followed was made from copper. However, its surfaces were coated with a thin layer of nickel and then with one of chromium. It was found that such a surface consistently promoted dropwise condensation and showed no signs of deterioration after lengthy periods of use. The rate of heat removal from pure steam and from mixtures of steam and air in varying proportions was measured as a function of plate sub-cooling for a variety of plate orientations. (author)
Development of balanced downflow type surface condensers, (2)
International Nuclear Information System (INIS)
Tomida, Akira; Oshima, Yoshikuni; Okochi, Isao; Izumi, Kenkichi.
1976-01-01
As the size of the condensers for power generation plants grew large, the new balanced downflow type condenser was developed and completed on the basis of the experiment on steam flow according to the two-dimensional flow model, the analysis of the performance in a tube nest with a computer, and the studies on the effect of outside liquid film and the reheating deaeration of condensate. When the balanced downflow type condensers were adopted for actual plants, the construction, strength and production method were examined, and the reliability of the new condenser was confirmed by the thermal characteristic experiment with the model similar to the actual machine. The condenser comprises a condenser body, supporting plates, cooling tubes, tube plates, water chambers, and reinforcements, and the cooling tubes are arranged so as to exchange heat effectively. The arrangement of tubes is divided into three regions, namely radiation portion, densely arranged portion, and air cooling portion. In the balanced downflow type condensers, the dilution by utilizing condensate is provided against ammonia attack. The apparatuses for the thermal characteristic experiment and the experimental results, and the results of the performance test on the actual balanced downflow type condenser are reported. (Kako, I.)
Optimal design of condenser weight
International Nuclear Information System (INIS)
Zheng Jing; Yan Changqi; Wang Jianjun
2011-01-01
The condenser is an important component in nuclear power plants, which dimension and weight will effect the economical performance and the arrangement of the nuclear power plants. In this paper, the calculation model is established according to the design experience. The corresponding codes are also developed, and the sensitivity of design parameters which influence the condenser weight is analyzed. The present design optimization of the condenser, taking the weight minimization as the objective, is carried out with the self-developed complex-genetic algorithm. The results show that the reference condenser design is far from the best scheme, and also verify the feasibility of the complex-genetic algorithm. (authors)
Condensation in Nanoporous Packed Beds.
Ally, Javed; Molla, Shahnawaz; Mostowfi, Farshid
2016-05-10
In materials with tiny, nanometer-scale pores, liquid condensation is shifted from the bulk saturation pressure observed at larger scales. This effect is called capillary condensation and can block pores, which has major consequences in hydrocarbon production, as well as in fuel cells, catalysis, and powder adhesion. In this study, high pressure nanofluidic condensation studies are performed using propane and carbon dioxide in a colloidal crystal packed bed. Direct visualization allows the extent of condensation to be observed, as well as inference of the pore geometry from Bragg diffraction. We show experimentally that capillary condensation depends on pore geometry and wettability because these factors determine the shape of the menisci that coalesce when pore filling occurs, contrary to the typical assumption that all pore structures can be modeled as cylindrical and perfectly wetting. We also observe capillary condensation at higher pressures than has been done previously, which is important because many applications involving this phenomenon occur well above atmospheric pressure, and there is little, if any, experimental validation of capillary condensation at such pressures, particularly with direct visualization.
Energy Technology Data Exchange (ETDEWEB)
Cho, Yong Jin; Ahn, Seung Hoon; Kim, Kap; Kim, Hho Jung [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)
2009-07-01
TRACE assessment was performed to investigate local condensation heat transfer coefficients in the presence of a noncondensable gas inside a vertical tube. The data obtained from pure steam and steam/nitrogen mixture condensation experiments were compared to study the effects of noncondensable nitrogen gas on the annular film condensation phenomena. The condenser tube had a small inner diameter of 13mm (about 1/2-in.) and this experiment had been performed to prove the effectiveness of the a Passive Residual Heat Removal System (PRHRS) of SMART (System-integrated Modular Advanced ReacTor), which is a small modular integral-type pressurized water reactor that is developed for the dual purposes of seawater desalination and small-scaled power generation. In the case of nitrogen presence, TRACE results show the converged results but the prediction is different from experimental data. The candidate reasons can be focused on several models, such as the film thickness calculation, surface area, and condensation heat transfer correlations, etc. In the case of pure steam condensation case, TRACE results shows large oscillations and do not converge. This should be investigated in detail to identify the reason. Until now, the oscillation in thermal hydraulic parameters results from the film thickness calculation and surface area calculation. For future works, the whole sets of the experiment will be assessed and the improvement of TRACE will be performed.
International Nuclear Information System (INIS)
Cho, Yong Jin; Ahn, Seung Hoon; Kim, Kap; Kim, Hho Jung
2009-01-01
TRACE assessment was performed to investigate local condensation heat transfer coefficients in the presence of a noncondensable gas inside a vertical tube. The data obtained from pure steam and steam/nitrogen mixture condensation experiments were compared to study the effects of noncondensable nitrogen gas on the annular film condensation phenomena. The condenser tube had a small inner diameter of 13mm (about 1/2-in.) and this experiment had been performed to prove the effectiveness of the a Passive Residual Heat Removal System (PRHRS) of SMART (System-integrated Modular Advanced ReacTor), which is a small modular integral-type pressurized water reactor that is developed for the dual purposes of seawater desalination and small-scaled power generation. In the case of nitrogen presence, TRACE results show the converged results but the prediction is different from experimental data. The candidate reasons can be focused on several models, such as the film thickness calculation, surface area, and condensation heat transfer correlations, etc. In the case of pure steam condensation case, TRACE results shows large oscillations and do not converge. This should be investigated in detail to identify the reason. Until now, the oscillation in thermal hydraulic parameters results from the film thickness calculation and surface area calculation. For future works, the whole sets of the experiment will be assessed and the improvement of TRACE will be performed
Havens, Vance; Ragaller, Dana
1988-01-01
Management of two-phase fluid and control of the heat transfer process in microgravity is a technical challenge that must be addressed for an orbital Organic Rankine Cycle (ORC) application. A test program was performed in 1-g that satisfactorily demonstrated the two-phase management capability of the rotating fluid management device (RFMD) and shear-flow condenser. Operational tests of the RFMD and shear flow condenser in adverse gravity orientations, confirmed that the centrifugal forces in the RFMD and the shear forces in the condenser were capable of overcoming gravity forces. In a microgravity environment, these same forces would not have to compete against gravity and would therefore be dominant. The specific test program covered the required operating range of the Space Station Solar Dynamic Rankine Cycle power system. Review of the test data verified that: fluid was pumped from the RFMD in all attitudes; subcooled states in the condenser were achieved; condensate was pushed uphill against gravity; and noncondensible gases were swept through the condenser.
Diagnosis of condensation-induced waterhammer: Case studies
International Nuclear Information System (INIS)
Izenson, M.G.; Rothe, P.H.; Wallis, G.B.
1988-10-01
This guidebook provides reference material and diagnostic procedures concerning condensation-induced waterhammer in nuclear power plants. Condensation-induced waterhammer is the most damaging form of waterhammer, and its diagnosis is complicated by the complex nature of the underlying phenomena. In Volume 1, the guidebook groups condensation-induced waterhammers into five event classes which have similar phenomena and levels of damage. Diagnostic guidelines focus on locating the event center where condensation and slug acceleration take place. Diagnosis is described in three stages: an initial assessment, detailed evaluation and final confirmation. Graphical scoping analyses are provided to evaluate whether an event from one of the event classes could have occurred at the event center. Examples are provided for each type of waterhammer. Special instructions are provided for walking down damaged piping and evaluating damage due to waterhammer. To illustrate the diagnostic methods and document past experience, six case studies have been compiled in Volume 2. These case studies, based on actual condensation-induced waterhammer events at nuclear plants, present detailed data and work through the event diagnosis using the tools introduced in the first volume. 20 refs., 21 figs., 6 tabs
Real-time monitoring energy efficiency and performance degradation of condensing boilers
Baldi, S.; Le, Q.T.; Holub, O.; Endel, P
2017-01-01
Condensing boilers achieve higher efficiency than traditional boilers by using waste heat in flue gases to preheat cold return water entering the boiler. Water vapor produced during combustion is condensed into liquid form, thus recovering its latent heat of vaporization, leading to around 10–12%
Experimental and numerical study of an evaporatively-cooled condenser of air-conditioning systems
International Nuclear Information System (INIS)
Islam, M.R.; Jahangeer, K.A.; Chua, K.J.
2015-01-01
The performance of an air-conditioning unit with evaporately-cooled condenser coil is studied experimentally and numerically. An experimental setup is fabricated by retrofitting a commercially available air-conditioning unit and installing comprehensive measuring sensors and controllers. Experimental result shows that the COP (Coefficient of Performance) of the evaporately-cooled air-conditioning unit increases by about 28% compared to the conventional air cooled air-conditioning unit. To analyze the heat and mass transfer processes involved in the evaporately-cooled condenser, a detailed theoretical model has been developed based on the fluid flow characteristics of the falling film and the thermodynamic aspect of the evaporation process. Simulated results agree well with experimental data. The numerical model provides new insights into the intrinsic links between operating variables and heat transfer characteristics of water film in evaluating the performance of evaporatively-cooled condenser system. Two heat transfer coefficients, namely, wall to bulk and bulk to interface are introduced and computed from the simulation results under different operating conditions. Finally, the overall heat transfer coefficient for the water film is computed and presented as a function of dimensionless variables which can conveniently be employed by engineers to design and analyze high performance evaporatively-cooled heat exchangers. - Highlights: • Performance of evaporatively-cooled condenser is investigated. • Local convective heat transfer coefficients of water film are determined. • Thermal resistance of water film is negligible. • Heat transfer with evaporated vapor plays significant role on performance. • Better condenser performance translates to an improvement in COP
A bubble column evaporator with basic flat-plate condenser for brackish and seawater desalination.
Schmack, Mario; Ho, Goen; Anda, Martin
2016-01-01
This paper describes the development and experimental evaluation of a novel bubble column-based humidification-dehumidification system, for small-scale desalination of saline groundwater or seawater in remote regions. A bubble evaporator prototype was built and matched with a simple flat-plate type condenser for concept assessment. Consistent bubble evaporation rates of between 80 and 88 ml per hour were demonstrated. Particular focus was on the performance of the simple condenser prototype, manufactured from rectangular polyvinylchlorid plastic pipe and copper sheet, a material with a high thermal conductivity that quickly allows for conduction of the heat energy. Under laboratory conditions, a long narrow condenser model of 1500 mm length and 100 mm width achieved condensate recovery rates of around 73%, without the need for external cooling. The condenser prototype was assessed under a range of different physical conditions, that is, external water cooling, partial insulation and aspects of air circulation, via implementing an internal honeycomb screen structure. Estimated by extrapolation, an up-scaled bubble desalination system with a 1 m2 condenser may produce around 19 l of distilled water per day. Sodium chloride salt removal was found to be highly effective with condensate salt concentrations between 70 and 135 µS. Based on findings and with the intent to reduce material cost of the system, a shorter condenser length of 750 mm for the non-cooled (passive) condenser and of 500 mm for the water-cooled condenser was considered to be equally efficient as the experimentally evaluated prototype of 1500 mm length.
Reliability assessment of passive isolation condenser system of AHWR using APSRA methodology
International Nuclear Information System (INIS)
Nayak, A.K.; Jain, Vikas; Gartia, M.R.; Prasad, Hari; Anthony, A.; Bhatia, S.K.; Sinha, R.K.
2009-01-01
In this paper, a methodology known as APSRA (Assessment of Passive System ReliAbility) is used for evaluation of reliability of passive isolation condenser system of the Indian Advanced Heavy Water Reactor (AHWR). As per the APSRA methodology, the passive system reliability evaluation is based on the failure probability of the system to perform the design basis function. The methodology first determines the operational characteristics of the system and the failure conditions based on a predetermined failure criterion. The parameters that could degrade the system performance are identified and considered for analysis. Different modes of failure and their cause are identified. The failure surface is predicted using a best estimate code considering deviations of the operating parameters from their nominal states, which affect the isolation condenser system performance. Once the failure surface of the system is predicted, the causes of failure are examined through root diagnosis, which occur mainly due to failure of mechanical components. Reliability of the system is evaluated through a classical PSA treatment based on the failure probability of the components using generic data
International Nuclear Information System (INIS)
Shin, Woo-Ju; Lee, Jong-Geon; Hwang, Jae-Sang; Seong, Jae-Kyu; Lee, Bang-Wook
2013-01-01
Highlights: •The optimum design of condenser cone cryogenic bushing was investigated. •Multi-layer aluminum foils in the bushing insulation body was designed and analyzed. •The optimum electric field distribution was selected by simulation. •The 60 kV FRP condenser cone cryogenic bushing was fabricated and tested. •BIL test corresponding to IEC 60137 was successfully performed for the bushing. -- Abstract: A cryogenic bushing is an essential component to be developed for commercial applications of high voltage (HV) superconducting devices. Due to the steep temperature gradient of the ambient of cryogenic bushing, general gas bushing adopting SF6 gas as an insulating media could not be directly used due to the freezing of SF6 gas. Therefore, condenser type bushing with special material considering cryogenic environment would be better choice for superconducting equipment. Considering these circumstance, we focused on the design of condenser bushing made of fiber reinforced plastic (FRP). In case of the design of the condenser bushing, it is very important to reduce the electric field intensification on the mounted flange part of the cryostat, which is the most vulnerable part of bushings. In this paper, design factors of cryogenic bushing were analyzed, and finally 60 kV condenser bushing was fabricated and tested. In order to achieve optimal electric field configuration, the configuration of condenser cone was determined using 2D electric field simulation results. Based on the experimental and the analytical works, 60 kV FRP condenser bushing was fabricated. Finally, the fabricated condenser bushing has been tested by applying lightning impulse and AC overvoltage test. From the test results, it was possible to get satisfactory results which confirm the design of cryogenic bushing in cryogenic environment
Energy Technology Data Exchange (ETDEWEB)
Shin, Woo-Ju, E-mail: shinwooju@hanyang.ac.kr; Lee, Jong-Geon; Hwang, Jae-Sang; Seong, Jae-Kyu; Lee, Bang-Wook, E-mail: bangwook@hanyang.ac.kr
2013-11-15
Highlights: •The optimum design of condenser cone cryogenic bushing was investigated. •Multi-layer aluminum foils in the bushing insulation body was designed and analyzed. •The optimum electric field distribution was selected by simulation. •The 60 kV FRP condenser cone cryogenic bushing was fabricated and tested. •BIL test corresponding to IEC 60137 was successfully performed for the bushing. -- Abstract: A cryogenic bushing is an essential component to be developed for commercial applications of high voltage (HV) superconducting devices. Due to the steep temperature gradient of the ambient of cryogenic bushing, general gas bushing adopting SF6 gas as an insulating media could not be directly used due to the freezing of SF6 gas. Therefore, condenser type bushing with special material considering cryogenic environment would be better choice for superconducting equipment. Considering these circumstance, we focused on the design of condenser bushing made of fiber reinforced plastic (FRP). In case of the design of the condenser bushing, it is very important to reduce the electric field intensification on the mounted flange part of the cryostat, which is the most vulnerable part of bushings. In this paper, design factors of cryogenic bushing were analyzed, and finally 60 kV condenser bushing was fabricated and tested. In order to achieve optimal electric field configuration, the configuration of condenser cone was determined using 2D electric field simulation results. Based on the experimental and the analytical works, 60 kV FRP condenser bushing was fabricated. Finally, the fabricated condenser bushing has been tested by applying lightning impulse and AC overvoltage test. From the test results, it was possible to get satisfactory results which confirm the design of cryogenic bushing in cryogenic environment.
Ren, Liqiang; Qiu, Yuchen; Li, Zheng; Li, Yuhua; Zheng, Bin; Li, Shibo; Chen, Wei R.; Liu, Hong
2013-02-01
As one of the important components of optical microscopes, the condenser has a considerable impact on system performance, especially on the depth of field (DOF). DOF is a critical technical feature in cytogenetic imaging that may affect the efficiency and accuracy of clinical diagnosis. The purpose of this study is to investigate the influence of microscopic condenser on DOF using a prototype of transmitted optical microscope, based on objective and subjective evaluations. After the description of the relationship between condenser and objective lens and the theoretical analysis of the condenser impact on system numerical aperture and DOF, a standard resolution pattern and several cytogenetic samples are adopted to assess the condenser impact on DOF, respectively. The experimental results of these objective and subjective evaluations are in agreement with the theoretical analysis and show that, under the specific intermediate range of condenser numerical aperture ( NAcond ), the DOF value decreases with the increase of NAcond . Although the above qualitative results are obtained under the experimental conditions with a specific prototype system, the methods presented in this preliminary investigation could offer useful guidelines for optimizing operational parameters in cytogenetic imaging.
Design of spiral fin type condenser for hydrogen cryogenic distillation column
International Nuclear Information System (INIS)
Iwai, Yasunori; Nishi, Masataka; Yamanishi, Toshihiko
2005-08-01
The purpose of this paper is the proposal of new concept condenser for hydrogen cryogenic distillation column of Hydrogen Isotope Separation System (ISS) in a fusion reactor, and the establishment of numerical evaluation method of the hydrogen isotope inventory in the condenser. A large amount of hydrogen isotopes including high concentration of tritium, radioactive hydrogen isotope, has been handled in the cryogenic distillation column. Therefore, from the safety point of view, cryogenic coolant tube was commonly arranged to surround the condensed area to prevent the mixing of tritium into the coolant. This inevitable arrangement leads the difficulty in the minimization of the condenser. The scale of condenser has influence on the scale of the ISS and its earthquake-resistance. The spiral fin type condenser, which introduces fins inside it and in coolant tube to enhance heat exchange, is proposed as a new concept condenser for hydrogen cryogenic distillation column to miniaturize the condenser. The volume of spiral fin type condenser is estimated to become less than half of that of coil tube type condenser currently in use. Accordingly, it is found that the adoption of spiral fin type condenser realizes the significant miniaturization of the ISS. Moreover, the numerical evaluation method of the hydrogen isotope inventory in the condenser is proposed. The validity of this method was confirmed by the experimental data. The synthetic design of the condenser for the hydrogen cryogenic distillation column is achieved by the combination of the proposed new concept condenser with the numerical evaluation method of the hydrogen isotope inventory. (author)
Evaluating the effect of the space surrounding the condenser of a household refrigerator
Energy Technology Data Exchange (ETDEWEB)
Bassiouny, Ramadan [Dept. of Mech. Power Eng. and Energy, Faculty of Engineering, Minia University, Minia 61111 (Egypt)
2009-11-15
The paper presents an analytical and computational modeling of the effect of the space surrounding the condenser of a household refrigerator on the rejected heat. The driving force for rejecting the heat carried by the refrigerant from the interior of a refrigerator is the temperature difference between the condenser outer surface and surrounding air. The variation of this difference, because of having an insufficient space, increasing the room air temperature, or blocking this space, is of interest to quantify its effect The results showed that having an enough surrounding space width (s > 200 mm) leads to a decrease in the temperature of the air flowing vertically around the condenser coil. Accordingly, this would significantly increase the amount of heat rejected. Moreover, blocking this space retards the buoyant flow up the condenser surface, and hence increases the air temperature around the condenser. This would also decrease the heat rejected from the condenser. Predicted temperature contours are displayed to visualize the air plumes' variation surrounding the condenser in all cases. (author)
Diagnosis of condensation-induced waterhammer: Methods and background
International Nuclear Information System (INIS)
Izenson, M.G.; Rothe, P.H.; Wallis, G.B.
1988-10-01
This guidebook provides reference material and diagnostic procedures concerning condensation-induced waterhammer in nuclear power plants. Condensation-induced waterhammer is the most damaging form of waterhammer and its diagnosis is complicated by the complex nature of the underlying phenomena. In Volume 1, the guidebook groups condensation-induced waterhammers into five event classes which have similar phenomena and levels of damage. Diagnostic guidelines focus on locating the event center where condensation and slug acceleration take place. Diagnosis is described in three stages: an initial assessment, detailed evaluation and final confirmation. Graphical scoping analyses are provided to evaluate whether an event from one of the event classes could have occurred at the event center. Examples are provided for each type of waterhammer. Special instructions are provided for walking down damaged piping and evaluating damage due to waterhammer. To illustrate the diagnostic methods and document past experience, six case studies have been compiled in Volume 2. These case studies, based on actual condensation-induced waterhammer events at nuclear plants, present detailed data and work through the event diagnosis using the tools introduced in the first volume. 65 figs., 8 tabs
On the design of residential condensing gas boilers
Energy Technology Data Exchange (ETDEWEB)
Naeslund, M.
1997-02-01
Two main topics are dealt with in this thesis. Firstly, the performance of condensing boilers with finned tube heat exchangers and premix burners is evaluated. Secondly, ways of avoiding condensate formation in the flue system are evaluated. In the first investigation, a transient heat transfer approach is used to predict performance of different boiler configurations connected to different heating systems. The smallest efficiency difference between heat loads and heating systems is obtained when the heat exchanger gives a small temperature difference between flue gases and return water, the heat transfer coefficient is low and the thermostat hysteresis is large. Taking into account heat exchanger size, the best boiler is one with higher heat transfer per unit area which only causes a small efficiency loss. The total heating cost at part load, including gas and electricity, has a maximum at the lowest simulated heat load. The heat supplied by the circulation heat pump is responsible for this. The second investigation evaluates methods of drying the flue gases. Reheating the flue gases in different ways and water removal in an adsorbent bed are evaluated. Reheating is tested in two specially designed boilers. The necessary reheating is calculated to approximately 100-150 deg C if an uninsulated masonry chimney is used. The tested boilers show that it is possible to design a proper boiler. The losses, stand-by and convective/radiative, must be kept at a minimum in order to obtain a high efficiency. 86 refs, 70 figs, 16 tabs
International Nuclear Information System (INIS)
Huh, Seon Jeong; Lee, Hee Joon; Moon, Joo Hyung; Bae, Youngmin; Kim, Young In
2017-01-01
For the design purpose of air-cooled condensing heat exchanger of emergency cooldown tank, average condensation heat transfer coefficient inside a circular tube was reduced by a thermal sizing program using the experimental data of Kim et al. It was compared to the existing condensation heat transfer correlations. Moreover, a sensitivity analysis of both inside condensation and outside air natural convection correlations was performed. Although condensation heat transfer did not play a great role to design over 10 3 W/m 2 /K, the improved Shah's correlation gives the best prediction for the design. Consequently, air natural convection coefficient significantly affects the design of air-cooled condensing heat exchanger. (author)
A study on passive containment cooling condensers in SBWR
International Nuclear Information System (INIS)
Kuran, S.; Soekmen; C. N.
2001-01-01
The passive containment cooling condensers (PCCC) are the crucial part of several new reactor designs, like European Simplified Boiling Water Reactor (ESBWR) and the SBWR. In a hypothetical accident, the pressurised steam non-condensable mixture from drywell is condensed in PCCCs, and condensate is returned to reactor vessel while non-condensable is vented through wet well. In this study, in order to examine the performance of PCCCs, condensation with presence of noncondensable is investigated. Condensation with different noncondensable types and conditions is studied on a PCCC model, which is developed by using RELAP5 Mod3.2 computer code
Energy Technology Data Exchange (ETDEWEB)
Kim, Sang Jae; No, Hee Cheon [KAIST, Taejon (Korea, Republic of)
1998-07-01
To investigate the physical parameters of PSCS (Passive Secondary Condensation System) which is a passive residual heat removal system of CP-1300, the high pressure condensation experiments are performed in a small scale experimental facility. The experimental parameters are the local heat flux and the transfer coefficient and the pressure drop in a condensation heat trasnfer. The film condensation heat transfer coefficients in a vertical tube are calculated from the measured wall temperature difference and compared with the analytical models. A new analytical condensation model is developed based on the annular film flow model. The present model gives marginally better results than those from the Shah model in comparison with the experimental data in the database. Also, experimental data are compared with the results of the RELAP5/MOD3.2 thermal hydraulic code. The RELAP5/MOD3.2 underpredicts the condensation heat transfer coefficients of the present experiment by 50 %.
A CFD study of wave influence on film steam condensation in the presence of non-condensable gas
Energy Technology Data Exchange (ETDEWEB)
Wang, Xianmao, E-mail: xm-wang11@mails.tsinghua.edu.cn [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Chang, Huajian, E-mail: changhj@tsinghua.edu.cn [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Corradini, Michael, E-mail: corradini@engr.wisc.edu [Department of Engineering Physics, University of Wisconsin-Madison, 1500 Engineering Drive, Madison, WI 53706 (United States)
2016-08-15
Highlights: • A condensation model is incorporated in the ANSYS FLUENT. • Different turbulence models are evaluated for flows over wavy surfaces. • Wavy surfaces with and without moving velocities are used to model the wave. • Various wavy surfaces with different wave heights and wavelengths are selected. • Wave influence on film steam condensation is investigated. - Abstract: Steam condensation plays an important role in removing heat from the containment of a nuclear plant during postulated accidents. However, due to the presence of non-condensable gases such as air and hydrogen in the containment, the condensation rate can decrease dramatically. Under certain conditions, the condensate film on the cold containment walls can affect the overall heat transfer rate. The wavy interface of the condensate film is a factor and is usually believed to enhance the condensation rate, since the waves can both increase the interfacial area and disturb the non-condensable gas boundary layer. However, it is not clear how to properly account for this factor and what is its quantitative influence in experiments. In this work, a CFD approach is applied to study the wave effects on film condensation in the presence of non-condensable gas. Wavy surfaces with and without moving velocities are used to replace the wavy interface of the falling film. A condensation model is incorporated in the ANSYS FLUENT simulation and a realizable k–ε turbulence model is applied. Various wavy surfaces with different wave heights and wavelengths are selected to conduct numerical experiments with a wide range of gas velocities. The results show that the wave structure can enhance condensation rate up to ten percent mainly due to the alteration of local flow structures in the gas phase. The increments of the condensation rate due to the wavy interface can vary with different gas velocities. The investigation shows that a multiplication factor accounts for the wave effects on film
THE MODEL FOR POWER EFFICIENCY ASSESSMENT OF CONDENSATION HEATING INSTALLATIONS
Directory of Open Access Journals (Sweden)
D. Kovalchuk
2017-11-01
Full Text Available The main part of heating systems and domestic hot water systems are based on the natural gas boilers. Forincreasing the overall performance of such heating system the condensation gas boilers was developed and are used. Howevereven such type of boilers don't use all energy which is released from a fuel combustion. The main factors influencing thelowering of overall performance of condensation gas boilers in case of operation in real conditions are considered. Thestructure of the developed mathematical model allowing estimating the overall performance of condensation gas boilers(CGB in the conditions of real operation is considered. Performace evaluation computer experiments of such CGB during aheating season for real weather conditions of two regions of Ukraine was made. Graphic dependences of temperatureconditions and heating system effectiveness change throughout a heating season are given. It was proved that normal CGBdoes not completely use all calorific value of fuel, thus, it isn't effective. It was also proved that the efficiency of such boilerssignificantly changes during a heating season depending on weather conditions and doesn't reach the greatest possible value.The possibility of increasing the efficiency of CGB due to hydraulic division of heating and condensation sections and use ofthe vapor-compression heat pump for deeper cooling of combustion gases and removing of the highest possible amount ofthermal energy from them are considered. The scheme of heat pump connection to the heating system with a convenient gasboiler and the separate condensation economizer allowing to cool combustion gases deeply below a dew point and to warm upthe return heat carrier before a boiler input is provided. The technological diagram of the year-round use of the heat pump forhot water heating after the end of heating season, without gas use is offered.
Direct contact condensation induced transition from stratified to slug flow
International Nuclear Information System (INIS)
Strubelj, Luka; Ezsoel, Gyoergy; Tiselj, Iztok
2010-01-01
Selected condensation-induced water hammer experiments performed on PMK-2 device were numerically modelled with three-dimensional two-fluid models of computer codes NEPTUNE C FD and CFX. Experimental setup consists of the horizontal pipe filled with the hot steam that is being slowly flooded with cold water. In most of the experimental cases, slow flooding of the pipe was abruptly interrupted by a strong slugging and water hammer, while in the selected experimental runs performed at higher initial pressures and temperatures that are analysed in the present work, the transition from the stratified into the slug flow was not accompanied by the water hammer pressure peak. That makes these cases more suitable tests for evaluation of the various condensation models in the horizontally stratified flows and puts them in the range of the available CFD (Computational Fluid Dynamics) codes. The key models for successful simulation appear to be the condensation model of the hot vapour on the cold liquid and the interfacial momentum transfer model. The surface renewal types of condensation correlations, developed for condensation in the stratified flows, were used in the simulations and were applied also in the regions of the slug flow. The 'large interface' model for inter-phase momentum transfer model was compared to the bubble drag model. The CFD simulations quantitatively captured the main phenomena of the experiments, while the stochastic nature of the particular condensation-induced water hammer experiments did not allow detailed prediction of the time and position of the slug formation in the pipe. We have clearly shown that even the selected experiments without water hammer present a tough test for the applied CFD codes, while modelling of the water hammer pressure peaks in two-phase flow, being a strongly compressible flow phenomena, is beyond the capability of the current CFD codes.
Effect on non-condensable gas on steam injector
International Nuclear Information System (INIS)
Kawamoto, Y.; Abe, Y.; Iwaki, C.; Narabayashi, T.; Mori, M.; Ohmori, S.
2004-01-01
Next-generation reactor systems have been under development aiming at simplified system and improvement of safety and credibility. A steam injector has a function of a passive pump without large motor or turbo-machinery, and has been investigated as one of the most important component of the next-generation reactor. Its performance as a pump depends on direct contact condensation phenomena between a supersonic steam and a sub-cooled water jet. Although non-condensable gases are well known for reducing heat transfer, the effect of the non-condensable gas on the condensation of supersonic steam on high-speed water jet has not been cleared. The present paper presents an experimental study of condensation of supersonic steam around turbulent water jet with model steam injector made by transparent plastic. The experimental apparatus is described. The visual observation was carried out by using high-speed camera. The non-condensable gas effect on the pump performance and flow characteristics are clarified by the image processing technique for the jet shape and gas-liquid interface behavior. (authors)
Demonstration of Nautilus Centripetal Capillary Condenser Technology
Wheeler, RIchard; Tang, Linh; Wambolt, Spencer; Golliher, Eric; Agui, Juan
2016-01-01
This paper describes the results of a proof of concept effort for development of a Nautilus Centripetal Capillary Condenser (NCCC or NC3) used for microgravity compatible water recovery from moist air with integral passive phase separation. Removal of liquid condensate from the air stream exiting a condenser is readily performed here on Earth. In order to perform this function in space however, without gravity or mechanical action, other tactics including utilization of inertial, drag and capillary forces are required. Within the NC3, liquid water forms via condensation on cold condenser surfaces as humid air passes along multiple spiral channels, each in its own plane, all together forming a stacked plate assembly. Non-mechanical inertial forces are employed to transfer condensate, as it forms, via centripetal action to the outer perimeter of each channel. A V-shaped groove, constructed on this outer edge of the spiral channel, increases local capillary forces thereby retaining the liquid. Air drag then pulls the liquid along to a collection region near the center of the device. Dry air produced by each parallel spiral channel is combined in a common orthogonal, out-of-plane conduit passing down the axial center of the stacked device. Similarly, the parallel condensate streams are combined and removed from the condenser/separator through yet another out-of-plane axial conduit. NC3 is an integration of conventional finned condenser operation, combined with static phase separation and capillary transport phenomena. A Mars' transit mission would be a logical application for this technology where gravity is absent and the use of vibrating, energy-intensive, motor-driven centrifugal separators is undesired. Here a vapor stream from either the Heat Melt Compactor or the Carbon dioxide Reduction Assembly, for example, would be dried to a dew point of 10 deg using a passive NC3 condenser/separator with the precious water condensate recycled to the water bus.
CONDENSATION OF WATER VAPOR IN A VERTICAL TUBE CONDENSER
Directory of Open Access Journals (Sweden)
Jan Havlík
2015-10-01
Full Text Available This paper presents an analysis of heat transfer in the process of condensation of water vapor in a vertical shell-and-tube condenser. We analyze the use of the Nusselt model for calculating the condensation heat transfer coefficient (HTC inside a vertical tube and the Kern, Bell-Delaware and Stream-flow analysis methods for calculating the shell-side HTC from tubes to cooling water. These methods are experimentally verified for a specific condenser of waste process vapor containing air. The operating conditions of the condenser may be different from the assumptions adopted in the basic Nusselt theory. Modifications to the Nusselt condensation model are theoretically analyzed.
Christensen, Anders S; Kromann, Jimmy C; Jensen, Jan H; Cui, Qiang
2017-10-28
To facilitate further development of approximate quantum mechanical methods for condensed phase applications, we present a new benchmark dataset of intermolecular interaction energies in the solution phase for a set of 15 dimers, each containing one charged monomer. The reference interaction energy in solution is computed via a thermodynamic cycle that integrates dimer binding energy in the gas phase at the coupled cluster level and solute-solvent interaction with density functional theory; the estimated uncertainty of such calculated interaction energy is ±1.5 kcal/mol. The dataset is used to benchmark the performance of a set of semi-empirical quantum mechanical (SQM) methods that include DFTB3-D3, DFTB3/CPE-D3, OM2-D3, PM6-D3, PM6-D3H+, and PM7 as well as the HF-3c method. We find that while all tested SQM methods tend to underestimate binding energies in the gas phase with a root-mean-squared error (RMSE) of 2-5 kcal/mol, they overestimate binding energies in the solution phase with an RMSE of 3-4 kcal/mol, with the exception of DFTB3/CPE-D3 and OM2-D3, for which the systematic deviation is less pronounced. In addition, we find that HF-3c systematically overestimates binding energies in both gas and solution phases. As most approximate QM methods are parametrized and evaluated using data measured or calculated in the gas phase, the dataset represents an important first step toward calibrating QM based methods for application in the condensed phase where polarization and exchange repulsion need to be treated in a balanced fashion.
Christensen, Anders S.; Kromann, Jimmy C.; Jensen, Jan H.; Cui, Qiang
2017-10-01
To facilitate further development of approximate quantum mechanical methods for condensed phase applications, we present a new benchmark dataset of intermolecular interaction energies in the solution phase for a set of 15 dimers, each containing one charged monomer. The reference interaction energy in solution is computed via a thermodynamic cycle that integrates dimer binding energy in the gas phase at the coupled cluster level and solute-solvent interaction with density functional theory; the estimated uncertainty of such calculated interaction energy is ±1.5 kcal/mol. The dataset is used to benchmark the performance of a set of semi-empirical quantum mechanical (SQM) methods that include DFTB3-D3, DFTB3/CPE-D3, OM2-D3, PM6-D3, PM6-D3H+, and PM7 as well as the HF-3c method. We find that while all tested SQM methods tend to underestimate binding energies in the gas phase with a root-mean-squared error (RMSE) of 2-5 kcal/mol, they overestimate binding energies in the solution phase with an RMSE of 3-4 kcal/mol, with the exception of DFTB3/CPE-D3 and OM2-D3, for which the systematic deviation is less pronounced. In addition, we find that HF-3c systematically overestimates binding energies in both gas and solution phases. As most approximate QM methods are parametrized and evaluated using data measured or calculated in the gas phase, the dataset represents an important first step toward calibrating QM based methods for application in the condensed phase where polarization and exchange repulsion need to be treated in a balanced fashion.
Ardita, I. N.; Subagia, I. W. A.
2018-01-01
The condensate water produced by indoor a split air conditioning is usually not utilized and thrown away into the environment. The result of measurement shows that the temperature of condensate water produced by split air conditioning is quite low, that is 19-22 °C at the rate of 16-20 mL / min and it has PH balance. Under such conditions, Air Condensate produced by split air conditioning should still be recovered as an additional cooling medium on the condenser. This research will re-investigate the use of condensate water as an intermittent additional cooling of the condenser to increase the cooling capacity and performance of the air conditioning system. This research is done by experimental method whose implementation includes; designing and manufacturing of experimental equipment, mounting measuring tools, experimental data retrieval, data processing and yield analysis. The experimental results show that the use of condensate water as an intermittent additional cooling medium on split air conditioning condenser can increase the refrigeration effect about 2%, cooling capacity about 4% and 7% of COP system. Experimental results also show a decrease in power consumption in the system compressor about 3%
Condensation and frost formation in heat exchangers
International Nuclear Information System (INIS)
Rostami, A.A.
1982-01-01
The occurence of condensation and of frost formation are considered for air to heat exchangers with emphasis on how such occurrences would affect the performance of such heat exchangers when they are used in ventilating applications. The formulations which predict performance are developed for parallel, counter flow and cross flow with either formation or condensation, and for condensation the consequences for evaporation of condensate and of the effect of longitudinal conduction in the walls of the exchanger are also considered. For the prediction of the exchanger performance with frost formation there must be specified the growth of the frost layer with time and existing theories for this growth are examined, a new method of calculation of the growth is presented and this is shown to give results for the growth that are in accord with available experimental evidence. This new theory for the growth of a frost layer is used to predict the performance of a parallel flow exchanger under conditions in which frost formation occurs, by successively applying the steady state performance calculation for time increments over which the frost layer build-up is calculated for these time increments. The calculation of counter flow exchanger performance by this method, while feasible, is so time consuming that only the general aspects of the calculation are considered
Single-tube condensation experiment in Passive Auxiliary Feedwater System of APR1400+
Energy Technology Data Exchange (ETDEWEB)
Shin, Chang Wook; No, Hee Cheon; Yun, Bong Yo; Jeon, Byong Guk [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)
2012-05-15
Conventional Korean nuclear power plants, Advanced Power Reactors (APR), are characterized by an active cooling system. However, Active cooling system may not prevent significant damage without any AC power source available for its operation as vividly illustrated through the recent Fukushima incident. In the APR1400+ to be designed, an independent passive cooling system was added in order to overcome the aforementioned shortcomings. In the Passive Auxiliary Feedwater System (PAFS), gravity force and density difference between steam and water are used. The system comprises of 240 condensation tubes to efficiently remove decay heat. Before applying the PAFS to APR1400+, the system's safety and heat removal performance must be verified. The present study experimentally evaluates the heat removal performance of a single tube in the PAFS. The objectives of SCOP (Single-tube Condensation experiment facility of PAFS) are the evaluation of the heat removal performance in the tube of the PAFS and database construction under various tube designs and test conditions. Reaching these objectives, we developed advanced measurement techniques for the amount of moisture, heat flux, and water film thickness.
International Nuclear Information System (INIS)
Masuda, Fujio
1980-01-01
Purpose: To enable safe steam condensation by providing steam condensation blades at the end of a pipe. Constitution: When high temperature high pressure steam flows into a vent pipe having an opening under water in a pool or an exhaust pipe or the like for a main steam eacape safety valve, non-condensable gas filled beforehand in the steam exhaust pipe is compressed, and discharged into the water in the pool. The non-condensable gas thus discharged from the steam exhaust pipe is introduced into the interior of the hollow steam condensing blades, is then suitably expanded, and thereafter exhausted from a number of exhaust holes into the water in the pool. In this manner, the non-condensable gas thus discharged is not directly introduced into the water in the pool, but is suitable expanded in the space of the steam condensing blades to suppress extreme over-compression and over-expansion of the gas so as to prevent unstable pressure vibration. (Yoshihara, H.)
Bubbler condenser related research work. Present situation
International Nuclear Information System (INIS)
2001-02-01
Intensive discussions within the OECD Support Group on 'VVER-440 Bubbler Condenser Containment Research Work' between 1991 and 1994 demonstrated the need for supplementary research work to achieve an adequate level of basic knowledge. In 1994, the European Commission (EC) asked for a specific 'VVER-440/213 Bubble Condenser Qualification Feasibility Study', which was finished early in 1996, confirming the need for additional research in this field. The Feasibility study formed the basis for the Bubble Condenser Experimental Qualification Project (BCEQ) with two separate experimental activities to be executed within the frame of the PHARE/TACIS 2.13/95 project of the European Commission. A first activity served to study the thermal-hydraulic phenomena and the associated structure dynamic interactions. This part of the project was performed at EREC, in Elektrogorsk, Russia. The design of the test facility was based on the prototypical bubbler condenser configuration for the Hungarian Paks nuclear power plant. A second activity addressed the structural integrity of certain components of the bubbler condenser steel structures under DBA-typical conditions. This part of the project was performed at VUEZ, in Levice, Slovak Republic. The design of the components of this facility was based on the structural properties of the Dukovany and/or Bohunice nuclear power plants. A third component of the BCEQ project was specified later asking for analytical studies, which should be supported by a number of small-scale separate effects tests to be performed at SVUSS, in Bechovice, Czech Republic. The main experimental and analytical results of the BCEQ test campaigns have been presented and discussed within the frame of the 4. meeting of the Technical Advisory Committee to the BCEQ (Bubble Condenser Experimental Qualification) Project in Brussels in December 1999 and on occasion of the 11. OECD Support Group Meeting in Berlin in April 2000. The discussions had evidenced several
Condensate subcooling near tube exit during horizontal in-tube condensation
International Nuclear Information System (INIS)
Hashizume, K.; Abe, N.; Ozeki, T.
1992-01-01
In-tube condensation is encountered in various applications for heat exchangers, such as domestic air-conditioning equipment, industrial air-cooled condensers, and moisture separator reheaters (MSRs) for nuclear power pants. Numerous research work has been conducted to predict the condensation heat transfer coefficient, and we have now enough information for thermal design of heat exchangers with horizontal in-tube condensation. Most of the research is analytical and/or experimental work in the annular or stratified flow regime, or experimental work on bulk condensation, i.e., from saturated vapor to complete condensation. On the other hand, there exist few data about the heat transfer phenomena in the very lower-quality region near the tube exit. The purpose of this paper is to clarify the condensation heat transfer phenomena near the tube exit experimentally and analytically, and to predict the degree of condensate subcooling
International Nuclear Information System (INIS)
Martínez, P.; Ruiz, J.; Cutillas, C.G.; Martínez, P.J.; Kaiser, A.S.; Lucas, M.
2016-01-01
A well known strategy for improving the performance of air conditioning systems when using air-condensed units is to decrease the ambient inlet airflow temperature by means of an evaporative cooling pad. In this work experiments are conducted in a split air-conditioning system where the condensing unit is modified by coupling different evaporative cooling pads with variable thickness. The impact of the different cooling pads on the overall performance of the air-conditioning system is experimentally determined by measuring the airflow conditions and the energy consumption of the overall air conditioning system, including both the condenser fan and the feedwater recirculation pump of the cooling pads. The aim is to determine the energy efficiency improvement achieved by pre-cooling the ambient airflow compared to a common air-condensed unit and to calculate the optimal pad thickness that maximize the overall COP of the system. Experimental results indicate that the best overall COP is obtained by adding a cooling pad thickness of about 100 mm. At that point the compressor power consumption is reduced by 11.4%, the cooling capacity is increased by 1.8% and finally the overall COP is increased by 10.6%.
International Nuclear Information System (INIS)
Boo, Joon Hong
2000-01-01
The thermal performance of a flat evaporator for Capillary Pumped Loop (CPL) applications was investigated. Two to four layers of coarse wire screen wicks were placed onto the heated surface to provide irregular passages for vapor flow. The evaporator and condenser were separated by a distance of 1.2 m and connected by individual liquid and vapor lines. The wall material was copper and the working fluid was ethanol. The experimental facility utilized a combination of capillary and gravitational forces for liquid return, and distribution over the evaporator surface. The tubing used for vapor and liquid lines was 9.35 mm or less in diameter and heat was removed from the condenser by convection of air. A heat flux of up to 4.9x10 4 W/m 2 was applied to a flat evaporator having dimensions of 100 mm by 200 mm, 20 mm thick. The thermal resistance of the system as well as the temperature characteristics of the system was investigated as the evaporator heat flux and the condenser cooling capacity varied. The performance of the evaporator and effect of condenser cooling capacity were analyzed and discussed
Design analysis of a Helium re-condenser
Muley, P. K.; Bapat, S. L.; Atrey, M. D.
2017-02-01
Modern helium cryostats deploy a cryocooler with a re-condenser at its II stage for in-situ re-condensation of boil-off vapor. The present work is a vital step in the ongoing research work of design of cryocooler based 100 litre helium cryostat with in-situ re-condensation. The cryostat incorporates a two stage Gifford McMahon cryocooler having specified refrigerating capacity of 40 W at 43 K for I stage and 1 W at 4.2 K for II stage. Although design of cryostat ensures thermal load for cryocooler below its specified refrigerating capacity at the second stage, successful in-situ re-condensation depends on proper design of re-condenser which forms the objective of this work. The present work proposes design of helium re-condenser with straight rectangular fins. Fins are analyzed for optimization of thermal performance parameters such as condensation heat transfer coefficient, surface area for heat transfer, re-condensing capacity, efficiency and effectiveness. The present work provides design of re-condenser with 19 integral fins each of 10 mm height and 1.5 mm thickness with a gap of 1.5 mm between two fins, keeping in mind the manufacturing feasibility, having efficiency of 80.96 % and effectiveness of 10.34.
Energy Technology Data Exchange (ETDEWEB)
Boccardi, G.; Celata, G.P.; Marchesi Donati, F. [ENEA, Rome (Italy). Inst. of Thermal-Fluid Dynamics; Cumo, M. [Rome Univ. La Sapienza, Rome (Italy). Dept. of Nuclear Engineering and Energy Conversion; Gerosa, A. [Rome Univ. Tor Vergata, Rome (Italy). Dept. of Mechanical Engineering; Zorzin, A. [R and D Alfa Laval Artec Spa Vicenza, Vicenza (Italy)
1999-12-01
An experimental campaign on plate heat exchangers, used as evaporators and condenser in domestic refrigeration loops is presented in this paper. The research's purpose is to test the influence of some thermal-hydraulic parameters on the global overall heat transfer coefficient. R134a, R407C, R410A, and R22 are the fluids tested under reference thermal conditions. The experimental tests allows one to withdraw conclusions on the substitution effect on the thermal and global efficiency of the plant. Also, a new method for calculating the thermodynamical mixture parameters is applied to the condensation of mixtures R407C and R410A and its benefit evaluated. The refrigerant loop overall performance and the condenser global heat transfer coefficient are the parameters chosen to enlighten the characteristics of the alternative refrigerants (R134a, R407C, and R410A) with respect to the fluid that they are supposed to substitute (R22). [Italian] Scambiatori a piastre compatti impiegati come evaporatori e condensatori nei circuiti frigoriferi, sono l'oggetto della ricerca presentata in questo articolo. L'efficienza termica di tali componenti e' valutata in condizioni di riferimento commerciali. I refrigeranti utilizzati sono tre fluidi proposti per sostituire l'R22, un Hcfc, attualmente il refrigerante piu' utilizzato nel condizionamento ambientale. Una serie di prove condotte con quest'ultimo fluido consente di studiare gli effetti della sostituzione del fluido di progetto sulle prestazioni sia degli scambiatori, sia piu' in generale, dell'intero circuito frigorifero. In particolare sono state studiate le prestazioni di due coppie di evaporatori e condensatori in termini di coefficiente globale di scambio termico e di Cop dell'impianto. Nel presente lavoro e' inoltre presentato e utilizzato un metodo termodinamico per il calcolo della temperatura di saturazione per le miscele zeotropiche in bifase; uno dei refrigeranti
Modeling of Kerena Emergency Condenser
Bryk, Rafał; Schmidt, Holger; Mull, Thomas; Wagner, Thomas; Ganzmann, Ingo; Herbst, Oliver
2017-12-01
KERENA is an innovative boiling water reactor concept equipped with several passive safety systems. For the experimental verification of performance of the systems and for codes validation, the Integral Test Stand Karlstein (INKA) was built in Karlstein, Germany. The emergency condenser (EC) system transfers heat from the reactor pressure vessel (RPV) to the core flooding pool in case of water level decrease in the RPV. EC is composed of a large number of slightly inclined tubes. During accident conditions, steam enters into the tubes and condenses due to the contact of the tubes with cold water at the secondary side. The condensed water flows then back to the RPV due to gravity. In this paper two approaches for modeling of condensation in slightly inclined tubes are compared and verified against experiments. The first approach is based on the flow regime map. Depending on the regime, heat transfer coefficient is calculated according to specific semi-empirical correlation. The second approach uses a general, fully-empirical correlation. The models are developed with utilization of the object-oriented Modelica language and the open-source OpenModelica environment. The results are compared with data obtained during a large scale integral test, simulating loss of coolant accident performed at Integral Test Stand Karlstein (INKA). The comparison shows a good agreement.Due to the modularity of models, both of them may be used in the future in systems incorporating condensation in horizontal or slightly inclined tubes. Depending on his preferences, the modeller may choose one-equation based approach or more sophisticated model composed of several exchangeable semi-empirical correlations.
Emergency condensator for BWR type reactor
International Nuclear Information System (INIS)
Ubakai, Yoichi; Narumi, Yuichi; Sakata, Yuji.
1992-01-01
An emergency condensator is constituted with heat transfer pipes, a steam chamber, an upper pipe plate, a lower pipe plate and a condensate chamber. The upper pipe plate is secured by supports, and a steam pipe is connected to the upper pipe plate. A condensate pipeline and a incondensible gas vent pipe are disposed to the condensate chamber. Taking thermal expansion of the steam pipes and thermal expansion of the heat transfer pipes into consideration, the heat transfer pipe is made as an L-shaped pipe having a vertical portion and a horizontal portion so as to absorb each of the thermal expansion smoothly. The L-shaped heat transfer pipes are constituted as a bundle of pipes having the end portions thereof secured to the upper pipe plate and the lower pipe plate. The emergency condensator is disposed in a emergency condensator pool chamber. Cooling water in contact with the outer side of the L-shaped heat transfer pipes is the pool water in the pool chamber, and the condensator chamber is disposed in concrete walls of the pool chamber. With such a constitution, stress due to thermal expansion of the heat transfer pipes is mitigated, and heat transfer performance, earth quake resistance and maintenancability are improved. (I.N.)
Performance Evaluation of the ISS Water Processor Multifiltration Beds
Bowman, Elizabeth M.; Carter, Layne; Wilson, Mark; Cole, Harold; Orozco, Nicole; Snowdon, Doug
2012-01-01
The ISS Water Processor Assembly (WPA) produces potable water from a waste stream containing humidity condensate and urine distillate. The primary treatment process is achieved in the Multifiltration Bed, which includes adsorbent media and ion exchange resin for the removal of dissolved organic and inorganic contaminants. The first Multifiltration Bed was replaced on ISS in July 2010 after initial indication of inorganic breakthrough. This bed was returned to ground in July 2011 for an engineering investigation. The water resident in the bed was analyzed for various parameters to evaluate adsorbent loading, performance of the ion exchange resin, microbial activity, and generation of leachates from the ion exchange resin. Portions of the adsorbent media and ion exchange resin were sampled and subsequently desorbed to identify the primary contaminants removed at various points in the bed. In addition, an unused Multifiltration Bed was evaluated after two years in storage to assess the generation of leachates during storage. This assessment was performed to evaluate the possibility that these leachates are impacting performance of the Catalytic Reactor located downstream of the Multifiltration Bed. The results of these investigations and implications to the operation of the WPA on ISS are documented in this paper.
The shear viscosity of a trapped Bose-condensed gas
International Nuclear Information System (INIS)
Shahzamanian, M.A.; Yavary, H.
2006-01-01
By obtaining Kubo formula type and using nonequilibrium Green's functions, we calculate the shear viscosity of a trapped Bose-condensed gas below and above the Bose-Einstein condensation temperature (T BEC ). The contributions of the interactions between condensate and noncondensate atoms and between noncondensate atoms take into account to the viscous relaxation time, by evaluating second order self-energies in Beliaev approximation
International Nuclear Information System (INIS)
O'Donovan, Alan; Grimes, Ronan
2014-01-01
Economic and environmental restrictions have resulted in an increase in the installation of air-cooled condensers (ACCs) in thermoelectric power plants located in arid regions. The traditional A-frame design is installed most frequently, despite an array of empirical evidence that shows it to suffer from significant inefficiencies. As a result, there is scope for improvement in condenser design and this paper presents one such approach – a novel modular air-cooled condenser (MACC). It is suggested that the unique ability of the MACC to continually vary fan speed could result in efficiency gains over a plant operating with existing state-of-the-art fixed speed ACCs. To determine the impact of installing the MACC on plant output, the steam-side characteristics were established through a series of experimental measurements taken on a full-scale prototype. The experimental arrangement and measurement technique ensured that conditions representative of an operational ACC were maintained throughout. The steam-side characteristics are quantified in terms of temperature, pressure and thermal resistance. Predicted values of these quantities are also presented, calculated from established theory. Both the measurements and predictions were used in a thermodynamic analysis to determine the performance of a 50 MW power plant. Results show that, for a given steam flow rate, increasing fan speed leads to a reduction in condenser pressure which ultimately, results in increased plant output. This occurs up until a certain point, at which further increases in output are offset by larger fan power consumption rates. Thus, an optimum operating point is shown to exist. The results from the thermodynamic analysis demonstrate discrepancies between the plant output evaluated from the measurements and that predicted from theory. In some cases, a difference as large as 1.5% was observed, equating to a 0.8 MW over-prediction by the theory. - Highlights: • A novel modular air
International Nuclear Information System (INIS)
Macedo, Luiz Alberto
2008-01-01
The research and the development of passive emergency cooling systems are necessary for the new generation of thermo-nuclear systems. Some basic information on the operation of these systems require the research of some relative processes to the natural circulation, mainly in conditions of two-phase flow involving processes of condensation in the presence of non-condensable gases, because many found situations are new. The experimental facility called Bancada de Circulacao Natural (BCN) was used for the realization of tests with diverse concentrations of non-condensable and power levels. The non-condensable gas present in the circuit decreases the rate of heat transfer for the secondary of the heat exchanger, determining low efficiency of the heat exchanger. High concentration of non-condensable in the vapor condensation, determines negative pressure, and cause the inversion of the flow in the circuit. The initial concentration of non-condensable and the geometry of the circuit, in the inlet of the heat exchanger, determines the establishment of transitory with two-phase flow. The BCN was performed with the computational code of Analysis of Accidents and Thermal-Hydraulics RELAP5/MOD 3.3 and, the calculated values had been compared with the experimental data, presenting good agreement for small non-condensable concentrations. The values calculated for high concentrations of non-condensable had been satisfactory after the circuit to have reached the temperature of saturation in the electric heater. (author)
Enhanced Evaporation and Condensation in Tubes
Honda, Hiroshi
A state-of-the-art review of enhanced evaporation and condensation in horizontal microfin tubes and micro-channels that are used for air-conditioning and refrigeration applications is presented. The review covers the effects of flow pattern and geometrical parameters of the tubes on the heat transfer performance. Attention is paid to the effect of surface tension which leads to enhanced evaporation and condensation in the microfin tubes and micro-channels. A review of prior efforts to develop empirical correlations of the heat transfer coefficient and theoretical models for evaporation and condensation in the horizontal microfin tubes and micro-channels is also presented.
Gravitationally Driven Wicking for Enhanced Condensation Heat Transfer.
Preston, Daniel J; Wilke, Kyle L; Lu, Zhengmao; Cruz, Samuel S; Zhao, Yajing; Becerra, Laura L; Wang, Evelyn N
2018-04-17
Vapor condensation is routinely used as an effective means of transferring heat or separating fluids. Filmwise condensation is prevalent in typical industrial-scale systems, where the condensed fluid forms a thin liquid film due to the high surface energy associated with many industrial materials. Conversely, dropwise condensation, where the condensate forms discrete liquid droplets which grow, coalesce, and shed, results in an improvement in heat transfer performance of an order of magnitude compared to filmwise condensation. However, current state-of-the-art dropwise technology relies on functional hydrophobic coatings, for example, long chain fatty acids or polymers, which are often not robust and therefore undesirable in industrial conditions. In addition, low surface tension fluid condensates, such as hydrocarbons, pose a unique challenge because common hydrophobic condenser coatings used to shed water (with a surface tension of 73 mN/m) often do not repel fluids with lower surface tensions (condensation heat transfer using gravitationally driven flow through a porous metal wick, which takes advantage of the condensate's affinity to wet the surface and also eliminates the need for condensate-phobic coatings. The condensate-filled wick has a lower thermal resistance than the fluid film observed during filmwise condensation, resulting in an improved heat transfer coefficient of up to an order of magnitude and comparable to that observed during dropwise condensation. The improved heat transfer realized by this design presents the opportunity for significant energy savings in natural gas processing, thermal management, heating and cooling, and power generation.
International Nuclear Information System (INIS)
Chan, K.T.; Yu, F.W.
2006-01-01
This paper presents a thermodynamic model to evaluate the coefficient of performance (COP) of an air-cooled screw chiller under various operating conditions. The model accounts for the real process phenomena, including the capacity control of screw compressors and variations in the heat-transfer coefficients of an evaporator and a condenser at part load. It also contains an algorithm to determine how the condenser fans are staged in response to a set-point condensing temperature. The model parameters are identified, based on the performance data of chiller specifications. The chiller model is validated using a wide range of operating data of an air-cooled screw chiller. The difference between the measured and modelled COPs is within ±10% for 86% of the data points. The chiller's COP can increase by up to 115% when the set-point condensing temperature is adjusted, based on any given outdoor temperature. Having identified the variation in the chiller's COP, a suitable strategy is proposed for air-cooled screw chillers to operate at maximum efficiency as much as possible when they have to satisfy a building's cooling-load
The report gives results of an evaluation of the heat transfer performance of pure hydrofluorocarbon (HFC)-236ea for high performance enhanced tubes which had not been previously used in Navy shipboard chillers. Shell-side heat transfer coefficient data are presented for condensa...
International Nuclear Information System (INIS)
Conroy, G.; Duffy, A.; Ayompe, L.M.
2014-01-01
Highlights: • The performance of a Stirling engine MK IV micro-CHP unit was evaluated in a domestic dwelling in Ireland. • The performance of the micro-CHP was compare to that of a condensing gas boiler. • The micro-CHP unit resulted in an annual cost saving of €180 compared to the condensing gas boiler. • Electricity imported from the grid decreased by 20.8% while CO 2 emissions decreased by 16.1%. • The micro-CHP unit used 2889 kW h of gas more than the condensing gas boiler during one year of operation. - Abstract: This paper presents an assessment of the energy, economic and greenhouse gas emissions performances of a WhisperGen Mk IV Stirling engine μ-CHP unit for use in a conventional house in the Republic of Ireland. The energy performance data used in this study was obtained from a field trial carried out in Belfast, Northern Ireland during the period June 2004–July 2005 by Northern Ireland Electricity and Phoenix Gas working in collaboration with Whispertech UK. A comparative performance analysis between the μ-CHP unit and a condensing gas boiler revealed that the μ-CHP unit resulted in an annual cost saving of €180 with an incremental simple payback period of 13.8 years when compared to a condensing gas boiler. Electricity imported from the grid decreased by 20.8% while CO 2 emissions decreased by 16.1%. The μ-CHP unit used 2889 kW h of gas more than the condensing gas boiler
Steam blowdown experiments with the condensation pool test rig
International Nuclear Information System (INIS)
Purhonen, H.; Puustinen, M.; Laine, J.; Raesaenen, A.; Kyrki-Rajamaeki, R.; Vihavainen, J.
2005-01-01
During a possible loss-of-coolant accident (Local) a large amount of non-condensable (nitrogen) and condensable (steam) gas is blown from the upper drywell of the containment to the condensation pool through the blowdown pipes at the boiling water reactors (BWRs). The wet well pool serves as the major heat sink for condensation of steam. The blowdown causes both dynamic and structural loads to the condensation pool. There might also be a risk that the gas discharging to the pool could push its way to the emergency core cooling systems (ECCS) and undermine their performance. (author)
Energy Technology Data Exchange (ETDEWEB)
De Walsche, C.; Cachard, F. de
2000-07-01
Experiments have been performed in the LINX facility to investigate condensation and mixing phenomena in pressure Suppression Pools (SPs), in the context of the European Simplified Boiling Water Reactor (ESBWR) study. As a contribution to the TEPSS project of the 4th European Framework Programme, eight medium-scale, separate-effect tests were carried out in which constant steam/air flow rates were injected below the surface of a two-metre diameter water pool, maintained at constant pressure, through a large downward vent. The vessel pressure was regulated, the pool temperature rising until equilibrium conditions with the incoming gas were reached. The SP temperature distribution was measured, as well as the inlet and outlet gas flow rates, and the overall condensation rate was estimated using mass and heat balances. The test matrix was based on steam mass floret and air mass fraction of the injected gas, the vent immersion depth, and the vessel pressure. Overall, the condensation was shown to be efficient for all tests performed, even for high non-condensable gas concentrations of the injected gas. Thermal stratification above the vent outlet was shown to be moderate. The tests performed allowed a better understanding to be gained of the mechanisms of condensation and mixing in the SP and Wetwell, and results were incorporated into an ORACLE database, to be used for further model development. (authors)
Modeling of Kerena Emergency Condenser
Directory of Open Access Journals (Sweden)
Bryk Rafał
2017-12-01
Full Text Available KERENA is an innovative boiling water reactor concept equipped with several passive safety systems. For the experimental verification of performance of the systems and for codes validation, the Integral Test Stand Karlstein (INKA was built in Karlstein, Germany. The emergency condenser (EC system transfers heat from the reactor pressure vessel (RPV to the core flooding pool in case of water level decrease in the RPV. EC is composed of a large number of slightly inclined tubes. During accident conditions, steam enters into the tubes and condenses due to the contact of the tubes with cold water at the secondary side. The condensed water flows then back to the RPV due to gravity. In this paper two approaches for modeling of condensation in slightly inclined tubes are compared and verified against experiments. The first approach is based on the flow regime map. Depending on the regime, heat transfer coefficient is calculated according to specific semi-empirical correlation. The second approach uses a general, fully-empirical correlation. The models are developed with utilization of the object-oriented Modelica language and the open-source OpenModelica environment. The results are compared with data obtained during a large scale integral test, simulating loss of coolant accident performed at Integral Test Stand Karlstein (INKA. The comparison shows a good agreement.Due to the modularity of models, both of them may be used in the future in systems incorporating condensation in horizontal or slightly inclined tubes. Depending on his preferences, the modeller may choose one-equation based approach or more sophisticated model composed of several exchangeable semi-empirical correlations.
Muthukumar, Palanisamy; Naik, Bukke Kiran; Goswami, Amarendra
2018-02-01
Mechanical draft cross flow cooling towers are generally used in a large-scale water cooled condenser based air-conditioning plants for removing heat from warm water which comes out from the condensing unit. During this process considerable amount of water in the form of drift (droplets) and evaporation is carried away along with the circulated air. In this paper, the performance evaluation of a standard cross flow induced draft cooling tower in terms of water loss, range, approach and cooling tower efficiency are presented. Extensive experimental studies have been carried out in three cooling towers employed in a water cooled condenser based 1200 TR A/C plant over a period of time. Daily variation of average water loss and cooling tower performance parameters have been reported for some selected days. The reported average water loss from three cooling towers is 4080 l/h and the estimated average water loss per TR per h is about 3.1 l at an average relative humidity (RH) of 83%. The water loss during peak hours (2 pm) is about 3.4 l/h-TR corresponding to 88% of RH and the corresponding efficiency of cooling towers varied between 25% and 45%.
Energy Technology Data Exchange (ETDEWEB)
Mendes da Silva, Julio Augusto; Pellegrini, Luiz Felipe; Oliveira Junior, Silvio [Polytechnic School of the University of Sao Paulo, SP (Brazil)], e-mails: jams@usp.br, luiz.pellegrini@usp.br, soj@usp.br; Plaza, Claudio; Rucker, Claudio [Petrobras - Petroleo Brasileiro S.A., Rio de Janeiro, RJ (Brazil)], e-mails: claudioplaza@petrobras.com.br, rucker@petrobras.com.br
2010-07-01
In this paper a brief description of the main processes present in a modern high capacity refinery is done. The methodology used to evaluate, through exergy analysis, the performance of the refinery's utilities plant since it is responsible for a very considerable amount of the total exergy destruction in a refinery is presented. The utilities plant products: steam, electricity, shaft power and high pressure water had their exergy unit cost determined using exergoeconomic approach. A simple and effective method called condensing to power was used to define the product of the condensers in exergy basis. Using this method it is possible to define the product of the condenser without the use of negentropy concept nor the aggregation of condensers to the steam turbines. By using this new approach, the costs obtained for the plant's products are exactly the same costs obtained when the condenser is aggregated to the steam turbine but with the advantage that the information about the stream between condenser and the steam turbine is not lost and the condenser can be evaluated singly. The analysis shows that the equipment where attention and resources should be focused are the boilers followed by the gas turbine, that together, are responsible for 80% of total exergy destruction in the utilities plant. The total exergy efficiency found for the utilities plant studied is 35% while more than 280 MW of exergy is destroyed in the utilities processes. (author)
DEFF Research Database (Denmark)
Jensen, Kasper Risgaard; Fojan, Peter; Jensen, Rasmus Lund
2014-01-01
The condensation of water is a phenomenon occurring in multiple situations in everyday life, e.g., when fog is formed or when dew forms on the grass or on windows. This means that this phenomenon plays an important role within the different fields of science including meteorology, building physics......, and chemistry. In this review we address condensation models and simulations with the main focus on heterogeneous condensation of water. The condensation process is, at first, described from a thermodynamic viewpoint where the nucleation step is described by the classical nucleation theory. Further, we address...
Assessment of RELAP5/MOD3 with condensation experiment for pure steam condensation in a vercal tube
Energy Technology Data Exchange (ETDEWEB)
Kim, Sang Jae; No, Hee Cheon [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)
1999-12-31
The film condensation models in RELAP5/MOD3.1 and RELAP5/MOD3.2 are assessed with the data of experiment performed in the scaled down condensation experimental facility with a single vertical tube of inner diameter of 46 mm in the range of pressure 0.1 {approx} 7.5 MPa for the PSCS(Passive Secondary Condenser System). Both MOD3.1 and MOD3.2 don`t shows any reliable predictions of the experimental data. The RELAP5/MOD3.1 overpredicts the heat transfer coefficients of experiment, whereas the RELAP5/MOD3.2 underpredicts those data. It is recommended that the film condensation model in RELAP5/MOD3.2 should be modified to have a larger heat transfer coefficient than those of the present model to give the reliable predictions. 7 refs., 6 figs., 1 tab. (Author)
Assessment of RELAP5/MOD3 with condensation experiment for pure steam condensation in a vercal tube
Energy Technology Data Exchange (ETDEWEB)
Kim, Sang Jae; No, Hee Cheon [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)
1998-12-31
The film condensation models in RELAP5/MOD3.1 and RELAP5/MOD3.2 are assessed with the data of experiment performed in the scaled down condensation experimental facility with a single vertical tube of inner diameter of 46 mm in the range of pressure 0.1 {approx} 7.5 MPa for the PSCS(Passive Secondary Condenser System). Both MOD3.1 and MOD3.2 don`t shows any reliable predictions of the experimental data. The RELAP5/MOD3.1 overpredicts the heat transfer coefficients of experiment, whereas the RELAP5/MOD3.2 underpredicts those data. It is recommended that the film condensation model in RELAP5/MOD3.2 should be modified to have a larger heat transfer coefficient than those of the present model to give the reliable predictions. 7 refs., 6 figs., 1 tab. (Author)
Performance Evaluation of An Innovative-Vapor- Compression-Desalination System
Directory of Open Access Journals (Sweden)
Mirna R. Lubis
2012-04-01
Full Text Available Two dominant desalination methods are reverse osmosis (RO and multi-stage flash (MSF. RO requires large capital investment and maintenance, whereas MSF is too energy-intensive. Innovative system of vapor compression desalination is proposed in this study. Comprehensive mathematics model for evaporator is also described. From literature study, it is indicated that very high overall-heat-transfer coefficient for evaporator can be obtained at specific condition by using dropwise condensation in the steam side, and pool boiling in the liquid side. Smooth titanium surface is selected in order to increase dropwise condensation, and resist corrosion. To maximize energy efficiency, a cogeneration scheme of a combined cycle consisting of gas turbine, boiler heat recovery, and steam turbine that drivescompressor is used. The resource for combined cycle is relatively too high for the compressor requirement. Excess power can be used to generate electricity for internal and/or externalconsumptions, and sold to open market. Four evaporator stages are used. Evaporator is fed by seawater, with assumption of 3.5% salt contents. Boiling brine (7% salt is boiled in low pressure side of the heat exchanger, and condensed vapor is condensed in high pressure side of the heat exchanger. Condensed steam flows at velocity of 1.52 m/s, so that it maximize the heat transfer coefficient. This unit is designed in order to produce 10 million gallon/day, and assumed it is financed with 5%, 30 years of passive obligation. Three cases are evaluated in order to determine recommended condition to obtain the lowest fixed capital investment. Based on the evaluation, it is possible to establish four-stage unit of mechanical vapor compression distillation with capital $31,723,885.
Condenser design for AMTEC power conversion
Crowley, Christopher J.
1991-01-01
The condenser and the electrodes are the two elements of an alkali metal thermal-to-electric conversion (AMTEC) cell which most greatly affect the energy conversion performance. A condenser is described which accomplishes two critical functions in an AMTEC cell: management of the fluid under microgravity conditions and optimization of conversion efficiency. The first function is achieved via the use of a controlled surface shape, along with drainage grooves and arteries to collect the fluid. Capillary forces manage the fluid in microgravity and dominate hydrostatic effects on the ground so the device is ground-testable. The second function is achieved via a smooth film of highly reflective liquid sodium on the condensing surface, resulting in minimization of parasitic heat losses due to radiation heat transfer. Power conversion efficiencies of 25 percent to 30 percent are estimated with this condenser using present technology for the electrodes.
Re-distribution (condensation) of magnons in a ferromagnet under pumping
International Nuclear Information System (INIS)
Zvyagin, A.A.
2008-01-01
In recent years several experiments have been performed to study the Bose-Einstein condensation of quasiparticles, in particular, magnons in magnetically ordered systems. Recently the Bose-Einstein condensation of magnons was observed at room temperatures in a ferromagnetic film. A theory of the condensation (redistribution) of magnons under the conditions of pumping, which explains many features of that experiment, is presented. The use of the term 'Bose-Einstein condensation of magnons' is discussed
Confirmatory tests of full-scale condensers for SBWR
International Nuclear Information System (INIS)
Masoni, P.; Botti, S.; Fitzsimmons, G.W.
1993-01-01
A full-scale isolation condenser and a full-scale passive containment cooling condenser for the Simplified Boiling Water Reactor (SBWR) will be tested to confirm the thermal-hydraulic and structural design characteristics of these components. The condensers provide vital roles in removing heat from the reactor vessel and the containment during certain design basis events. This paper describes the condensers and the test facilities which are under construction and summarizes the test objectives, the planned instrumentation, and the conditions to be tested. The results of some pre-test performance predictions, calculated with the TRACG code are presented. The results of the testing program are expected to demonstrate that the condenser designs will provide the required heat removal capacity and will survive the design basis temperature/pressure cycles without structural damage
Heat transfer from a high temperature condensable mixture. II. Sedimentation of fog condensate
International Nuclear Information System (INIS)
Condiff, D.W.; Cho, D.H.; Chan, S.H.
1985-01-01
A kinematic wave analysis of fog sedimentation is employed to relate growth of a fog condensate deposit layer to radiation generated fog formation rates. The increase of surface radiation absorptivity with deposit layer thickness promotes a feedback mechanism for higher growth rates, which is evaluated in detail
An evaluation of thermal-hydrodynamics for condensation pool and piping system
Energy Technology Data Exchange (ETDEWEB)
Kwon, Soon Bum; Lee, B. E.; Baek, S. C.; Joo, S. Y.; Lee, D. E.; Woo, S. W. [Kyungpook National Univ., Daegu (Korea, Republic of)
2003-03-15
If the steam with high pressure and high temperature at APR-1400 is discharged into IRWST through, the spargers submerged into it to release the pressure of coolant system 10 accident. The shock wave accompanying unsteady flow motion is propagated through the various piping system, it exerts high pressure load on units and may cause the structural problems and severe vibration. From the viewpoint of nuclear power plant safety, The analysis of flow behaviors 10 the IRWST and piping system is essential to achieve the technology for the evaluation of safety. And also he evaluation methods by the analysis of thermal hydrodynamic behaviors through the sparger is established. The results obtained show that the initial shock wave experienced reflection, diffraction and interaction with shock-induced vortex. The time-dependent maximum load exerted on the wall is largest 10 the T-junction, while the smallest 10 the branch. It is found that because there is nearly no change 10 pressure at condensation pool during water clearing, the system appears to be safe. However, calculations of the air clearing for 0.2 second were performed using VOF model to analyze air that coexist with water between load reduction and sparger head. In addition, since actual POSRV opening takes finite time of 1.7 second, it is expected that the flow field will be different from the that of instant opening the valve. Therefore, now the grid generation is proceeded for the case of POSRV opening at finite time of 1.7 second consecutively. The future study alms at flow analysis of POSRV opening at finite time, changing boundary conditions for wall into pressure inlet.
Condensate cosmology: Dark energy from dark matter
International Nuclear Information System (INIS)
Bassett, Bruce A.; Parkinson, David; Kunz, Martin; Ungarelli, Carlo
2003-01-01
Imagine a scenario in which the dark energy forms via the condensation of dark matter at some low redshift. The Compton wavelength therefore changes from small to very large at the transition, unlike quintessence or metamorphosis. We study cosmic microwave background (CMB), large scale structure, supernova and radio galaxy constraints on condensation by performing a four parameter likelihood analysis over the Hubble constant and the three parameters associated with Q, the condensate field: Ω Q , w f and z t (energy density and equation of state today, and redshift of transition). Condensation roughly interpolates between ΛCDM (for large z t ) and SCDM (low z t ) and provides a slightly better fit to the data than ΛCDM. We confirm that there is no degeneracy in the CMB between H and z t and discuss the implications of late-time transitions for the Lyman-α forest. Finally we discuss the nonlinear phase of both condensation and metamorphosis, which is much more interesting than in standard quintessence models
Experimental Investigation of Flow Condensation in Microgravity
Lee, Hyoungsoon; Park, Ilchung; Konishi, Christopher; Mudawar, Issam; May, Rochelle I.; Juergens, Jeffery R.; Wagner, James D.; Hall, Nancy R.; Nahra, Henry K.; Hasan, Mohammed M.;
2013-01-01
Future manned missions to Mars are expected to greatly increase the space vehicle's size, weight, and heat dissipation requirements. An effective means to reducing both size and weight is to replace single-phase thermal management systems with two-phase counterparts that capitalize upon both latent and sensible heat of the coolant rather than sensible heat alone. This shift is expected to yield orders of magnitude enhancements in flow boiling and condensation heat transfer coefficients. A major challenge to this shift is a lack of reliable tools for accurate prediction of two-phase pressure drop and heat transfer coefficient in reduced gravity. Developing such tools will require a sophisticated experimental facility to enable investigators to perform both flow boiling and condensation experiments in microgravity in pursuit of reliable databases. This study will discuss the development of the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS), which was initiated in 2012 in collaboration between Purdue University and NASA Glenn Research Center. This facility was recently tested in parabolic flight to acquire condensation data for FC-72 in microgravity, aided by high-speed video analysis of interfacial structure of the condensation film. The condensation is achieved by rejecting heat to a counter flow of water, and experiments were performed at different mass velocities of FC-72 and water and different FC-72 inlet qualities. It is shown that the film flow varies from smooth-laminar to wavy-laminar and ultimately turbulent with increasing FC-72 mass velocity. The heat transfer coefficient is highest near the inlet of the condensation tube, where the film is thinnest, and decreases monotonically along the tube, except for high FC-72 mass velocities, where the heat transfer coefficient is enhanced downstream. This enhancement is attributed to both turbulence and increased interfacial waviness. One-ge correlations are shown to
Calculation of the emergency condenser of the indirect cycle reactor CAREM
International Nuclear Information System (INIS)
Walter, D.; Schaffrath, A.
2002-08-01
CAREM is an Argentine project to achieve the development, design and construction of an innovative, simple and small Nuclear Power Plant (NPP). This NPP has an indirect cycle reactor with some distinctive and characteristic features (e.g. integrated primary cooling system by natural circulation, self-pressurized primary system and passive safety systems, etc.). In the frame of an IAEA forwarded HUMAN RESOURCES DEVELOPMENT - 'Advice on CAREM passive emergency condenser' at the Centro Atomico in San Carlos de Bariloche (Argentina) German experimental as well as analytical investigations of passive safety systems - mainly performed at the research centers Juelich and Rossendorf - were presented. During this visit it was decided that FZR should determine the emergency condenser capacity by using the ATHLET code with and without the condensation module extension KONWAR (condensation inside horizontal tube). These results should be compared and assessed with existing RELAP calculations. The ATHLET and ATHLET/KONWAR calculations of the emergency condenser were used for minimizing the user influence performed with exactly the same nodalization scheme and the same initial and boundary conditions than the RELAP calculations. The comparison of all three computational results shows that the required condenser capacities were achieved. The magnitudes were in order of up to 12%. An additionally performed evaluation of local flow parameters show large deviations especially for the heat transfer coefficients at the inner and outer tube wall. Due to the good validation progress of KONWAR by an extensive module validation against NOKO and HORUS experiments, the focus of the further investigation were concentrated on the boiling heat transfer. A comparison of the ATHLET boiling model (according to Forster and Zuber in combination with the equation of Thom for the determination of temperature difference between wall and saturated fluid) with other models from literature (Borishansky
Scrutinizing the pion condensed phase
Energy Technology Data Exchange (ETDEWEB)
Carignano, Stefano; Mammarella, Andrea; Mannarelli, Massimo [INFN, Laboratori Nazionali del Gran Sasso, Assergi (Italy); Lepori, Luca [Universita di Padova, Dipartimento di Fisica e Astronomia, Padova (Italy); Universita dell' Aquila, Dipartimento di Scienze Fisiche e Chimiche, Coppito-L' Aquila (Italy); Pagliaroli, Giulia [INFN, Laboratori Nazionali del Gran Sasso, Assergi (Italy); Gran Sasso Science Institute, L' Aquila (Italy)
2017-02-15
When the isospin chemical potential exceeds the pion mass, charged pions condense in the zero-momentum state forming a superfluid. Chiral perturbation theory provides a very powerful tool for studying this phase. However, the formalism that is usually employed in this context does not clarify various aspects of the condensation mechanism and makes the identification of the soft modes problematic. We re-examine the pion condensed phase using different approaches within the chiral perturbation theory framework. As a first step, we perform a low-density expansion of the chiral Lagrangian valid close to the onset of the Bose-Einstein condensation. We obtain an effective theory that can be mapped to a Gross-Pitaevskii Lagrangian in which, remarkably, all the coefficients depend on the isospin chemical potential. The low-density expansion becomes unreliable deep in the pion condensed phase. For this reason, we develop an alternative field expansion deriving a low-energy Lagrangian analog to that of quantum magnets. By integrating out the ''radial'' fluctuations we obtain a soft Lagrangian in terms of the Nambu-Goldstone bosons arising from the breaking of the pion number symmetry. Finally, we test the robustness of the second-order transition between the normal and the pion condensed phase when next-to-leading-order chiral corrections are included. We determine the range of parameters for turning the second-order phase transition into a first-order one, finding that the currently accepted values of these corrections are unlikely to change the order of the phase transition. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Yamashita, K; Kumagai, M; Sekita, S [Toshiba Corp., Tokyo (Japan); Yabe, A; Taketani, T; Kikuchi, K [Mechanical Engineering Laboratory, Tsukuba (Japan)
1991-05-25
As a series of high performance heat pump R and D as requested by the NEDO, the electrohydrodynamical (EHD) effect being applied to a shell-tube type heat exchanger, experiment to put it to practical use was made under a high temperature and high pressure condition to assume the heat pump. Design and manufacture being made of a 50kW class shell-tube type EHD condenser, the use of C {sub 6} F {sub 14} at 150 centigrade in temperature had the condensation heat transfer attain in enhancement ratio, at the highest, to six times as high as conventional. At that time, the consumed power at the helical wire with-lattice electrode was 0.0001% of the converted quantity of heat so that it could be limited to a negligibly very small value. For the EHD condenser, the condensation heat transfer enhancement method with use of the helical wire with-lattice electrode had its enhancement performance known to be effective in case that the heat transfer tube was long or that the medium was small in condensation latent heat. As a heat pump use condenser, there was known not to occur degradation in condensation heat transfer performance nor large enlargement in consumed power by lubrication oil, contained in the compressor. 9 refs., 14 figs., 1 tab.
Ice condenser experimental plan
International Nuclear Information System (INIS)
Kannberg, L.D.; Piepel, G.F.; Owczarski, P.C.; Liebetrau, A.M.
1986-01-01
An experimental plan is being developed to validate the computer code ICEDF. The code was developed to estimate the extent of aerosol retention in the ice compartments of pressurized water reactor ice condenser containment systems during severe accidents. The development of the experimental plan began with review of available information on the conditions under which the code will be applied. Computer-generated estimates of thermohydraulic and aerosol conditions entering the ice condenser were evaluated and along with other information, used to generate design criteria. The design criteria have been used for preliminary test assembly design and for generation of statistical test designs. Consideration of the phenomena to be evaluated in the testing program, as well as equipment and measurement limitations, have led to changes in the design criteria and to subsequent changes in the test assembly design and statistical test design. The overall strategy in developing the experimental plan includes iterative generation and evaluation of candidate test designs using computer codes for statistical test design and ICEDF for estimation of experimental results. Estimates of experimental variability made prior to actual testing will be verified by replicate testing at preselected design points
Impact of element-level static condensation on iterative solver performance
Pardo, D.; Á lvarez-Aramberri, J.; Paszynski, M.; Dalcin, Lisandro; Calo, Victor M.
2015-01-01
that static condensation at the element level is beneficial for higher-order methods. For lower-order methods or when the number of iterations required for convergence is low, the setup cost of the elimination as well as its implementation may offset
Liquid oil production from shale gas condensate reservoirs
Sheng, James J.
2018-04-03
A process of producing liquid oil from shale gas condensate reservoirs and, more particularly, to increase liquid oil production by huff-n-puff in shale gas condensate reservoirs. The process includes performing a huff-n-puff gas injection mode and flowing the bottom-hole pressure lower than the dew point pressure.
Intermolecular interactions in the condensed phase
DEFF Research Database (Denmark)
Christensen, Anders S.; Kromann, Jimmy Charnley; Jensen, Jan Halborg
2017-01-01
To facilitate further development of approximate quantum mechanical methods for condensed phase applications, we present a new benchmark dataset of intermolecular interaction energies in the solution phase for a set of 15 dimers, each containing one charged monomer. The reference interaction energy...... and solution phases. As most approximate QM methods are parametrized and evaluated using data measured or calculated in the gas phase, the dataset represents an important first step toward calibrating QM based methods for application in the condensed phase where polarization and exchange repulsion need...
International Nuclear Information System (INIS)
Prisyazhniuk, V.A.
2002-01-01
An equation for nucleation kinetics in steam condensation has been derived, the equation taking into account the concurrent and independent functioning of two nucleation mechanisms: the homogeneous one and the heterogeneous one. The equation is a most general-purpose one and includes all the previously known condensation models as special cases. It is shown how the equation can be used in analyzing the process of steam condensation in the condenser of an industrial steam-turbine plant, and in working out new ways of raising the efficiency of the condenser, as well as of the steam-turbine plant as a whole. (orig.)
Wang, H. S.; Honda, Hiroshi
A theoretical study has been made on the effects of tube diameter and tubeside fin geometry on the heat transfer performance of air-cooled condensers. Extensive numerical calculations of overall heat transfer from refrigerant R410A flowing inside a horizontal microfin tube to ambient air were conducted for a typical operating condition of the air-cooled condenser. The tubeside heat transfer coefficient was calculated by applying a modified stratified flow model developed by Wang et al.8). The numerical results show that the effects of tube diameter, fin height, fin number and helix angle of groove are significant, whereas those of the width of flat portion at the fin tip, the radius of round corner at the fin tip and the fin half tip angle are small.
Modelling of condensation phenomena
International Nuclear Information System (INIS)
Jeong, Jae Jun; Chang, Won Pyo
1996-07-01
Condensation occurs when vapor is cooled sufficiently below the saturation temperature to induce the nucleation of droplets. Such nucleation may occur homogeneously within the vapor or heterogeneously on entrained particular matter. Heterogeneous nucleation may occur on the walls of the system, where the temperature is below the saturation temperature. There are two forms of heterogeneous condensation, drop-wise and film-wise. Another form of condensation occurs when vapor directly contacts to subcooled liquid. In nuclear power plant systems, all forms of condensation may occur during normal operation or accident conditions. In this work the modelling of condensation is surveyed, including the Nusselts' laminar film condensation theory in 1916, Rohsenow's turbulent film condensation model in 1950s, and Chen's models in 1987. Major attention is paid on the film condensation models among various research results because of its importance in engineering applications. It is found that theory, experiment, and empirical correlations for film condensation are well established, but research for drop-wise and direct-contact condensation are not sufficient yet. Condensation models in the best-estimate system codes such as RELAP5/MOD3 and CATHARE2 are also investigated. 3 tabs., 11 figs., 36 refs. (Author)
Review of steam jet condensation in a water pool
International Nuclear Information System (INIS)
Kim, Y. S.; Song, C. H.; Park, C. K.; Kang, H. S.; Jeon, H. G.; Yoon, Y. J.
2002-01-01
In the advanced nuclear power plants including APR1400, the SDVS is adopted to increase the plant safety using the concept of feed-and-bleed operation. In the case of the TLOFW, the POSRV located at the top of the pressurizer is expected to open due to the pressurization of the reactor coolant system and discharges steam and/or water mixture into the water pool, where the mixture is condensed. During the condensation of the mixture, thermal-hydraulic loads such as pressure and temperature variations are induced to the pool structure. For the pool structure design, such thermal-hydraulic aspects should be considered. Understanding the phenomena of the submerged steam jet condensation in a water pool is helpful for system designers to design proper pool structure, sparger, and supports etc. This paper reviews and evaluates the steam jet condensation in a water pool on the physical phenomena of the steam condensation including condensation regime map, heat transfer coefficient, steam plume, steam jet condensation load, and steam jet induced flow
International Nuclear Information System (INIS)
Efanov, A. D.; Kalyakin, S. G.; Morozov, A. V.; Remizov, O. V.; Tsyganok, A. A.; Generalov, V. N.; Berkovich, V. M.; Taranov, G. S.
2008-01-01
performed to investigate the effect of non-condensable gases on condensation mode of operation of SG model at the pressure 0.25-0.3 MPa, correspond to WER reactor pressure at the last stage of the beyond design basis accident. (authors)
Schröder, J; Raiber, S; Berger, T; Schmidt, A; Schmidt, J; Soares-Sello, A M; Bardshiri, E; Strack, D; Simpson, T J; Veit, M; Schröder, G
1998-06-09
Heterologous screening of a cDNA library from Pinusstrobus seedlings identified clones for two chalcone synthase (CHS) related proteins (PStrCHS1 and PStrCHS2, 87.6% identity). Heterologous expression in Escherichia coli showed that PStrCHS1 performed the typical CHS reaction, that it used starter CoA-esters from the phenylpropanoid pathway, and that it performed three condensation reactions with malonyl-CoA, followed by the ring closure to the chalcone. PstrCHS2 was completely inactive with these starters and also with linear CoA-esters. Activity was detected only with a diketide derivative (N-acetylcysteamine thioester of 3-oxo-5-phenylpent-4-enoic acid) that corresponded to the CHS reaction intermediate postulated after the first condensation reaction. PstrCHS2 performed only one condensation, with 6-styryl-4-hydroxy-2-pyrone derivatives as release products. The enzyme preferred methylmalonyl-CoA against malonyl-CoA, if only methylmalonyl-CoA was available. These properties and a comparison with the CHS from Pinus sylvestris suggested for PstrCHS2 a special function in the biosynthesis of secondary products. In contrast to P. sylvestris, P. strobus contains C-methylated chalcone derivatives, and the methyl group is at the position predicted from a chain extension with methylmalonyl-CoA in the second condensation of the biosynthetic reaction sequence. We propose that PstrCHS2 specifically contributes the condensing reaction with methylmalonyl-CoA to yield a methylated triketide intermediate. We discuss a model that the biosynthesis of C-methylated chalcones represents the simplest example of a modular polyketide synthase.
Grimmer, G; Brune, H; Deutsch-Wenzel, R; Naujack, K W; Misfeld, J; Timm, J
1983-11-01
The objective of this investigation was to identify the substances chiefly responsible for the carcinogenicity of automobile exhaust condensate using topical application onto the skin of mice. This was performed by comparing the carcinogenic effect of various fractions with that of an unseparated sample of automobile exhaust condensate, tested in 3 different doses. The probit and Weibull analysis of the result shows: (a) The condensate, emitted from a gasoline-driven automobile provokes local tumors after long-term application to the dorsal skin of mice. The tumor incidence demonstrates a clear cut dose-response relationship. (b) The fraction of polycyclic aromatic hydrocarbons (PAH) containing more than 3 rings accounts for about 84-91% of the total carcinogenicity of automobile exhaust condensate. This fraction represents only about 3.5% by wt of the condensate. (c) The content of benzo[a]pyrene (BaP) (0.414 mg/g) accounts for 6-7.6% of the total carcinogenicity of automobile exhaust condensate, 15 selected PAHs for about 41%. (d) Regarding the minor effect of the PAH-free fraction (about 83% by wt), no hints for a cocarcinogenic activity were observed.
International Nuclear Information System (INIS)
Yamamoto, Michiyoshi; Oosumi, Katsumi; Takashima, Yoshie; Mitani, Shinji.
1982-01-01
Purpose: To decrease the frequency for the backwash and regeneration operations due to the increase in the differential pressure resulted from claddings captured in a mixed floor type desalter, and decrease the amount of radioactive liquid wastes of claddings from the condensate systems by removing claddings with electromagnetic filters. Constitution: In an existent plant, a valves is disposed between a condensate pump and a mixed floor type desalter. A pipeway is branched from a condensate pipe between the condensate pipe and the valve, through which condensates are transferred by a pump to an electromagnetic filter such as of a high gradient type electromagntic filter to remove claddings, then returned to a condensate pipe between the valve and the mixed floor type desalter and, thereafter, are removed with ionic components in the mixed floor type desalter and fed to the reactor. (Yoshino, Y.)
Charef, Adil; Feddaoui, M'barek; Najim, Monssif; Meftah, Hicham
2018-04-01
A computational study of the liquid film condensation from vapour-gas mixtures of HFC refrigerants inside a vertical tube is performed. The external wall of the tube is subjected to constant temperature. The model uses an implicit finite difference method to solve the governing equations for the liquid film and gas flow together including the boundary and interfacial matching conditions. Parametric computations were realised to examine the effects of inlet Reynolds number, tube length, and inlet temperature of the gas mixtures on the condensation mechanism. A comparative study between the results obtained for studied R152 a and R134 a with presence of non-condensable gas is made. The predicted results indicate that the condensation of R152 a-air corresponds to a higher accumulated condensation m c d and local heat transfer coefficient h T when compared to R134 a-air in the same conditions. Increasing the inlet Reynolds number or the tube length improve the condensation. Additionally, lower non-condensable gas in R152 a - a i r substantially enhances the heat and mass exchanges.
Energy Technology Data Exchange (ETDEWEB)
Buschman, Francis X., E-mail: Francis.Buschman@unnpp.gov; Aumiller, David L.
2017-02-15
Highlights: • Direct contact condensation data on liquid jets up to 1.7 MPa in pure steam and in the presence of noncondensable gas. • Identified a pressure effect on the impact of noncondensables to suppress condensation heat transfer not captured in existing data or correlations. • Pure steam data is used to develop a new correlation for condensation heat transfer on subcooled liquid jets. • Noncondensable data used to develop a modification to the renewal time estimate used in the Young and Bajorek correlation for condensation suppression in the presence of noncondensables. • A jet injection boundary condition, using a sub-grid jet condensation model, is developed for COBRA-IE which provides a more detailed estimate of the condensation rate on the liquid jet and allows the use of jet specific closure relationships. - Abstract: Condensation on liquid jets is an important phenomenon for many different facets of nuclear power plant transients and analyses such as containment spray cooling. An experimental facility constructed at the Pennsylvania State University, the High Pressure Liquid Jet Condensation Heat Transfer facility (HPLJCHT), has been used to perform steady-state condensation heat transfer experiments in which the temperature of the liquid jet is measured at different axial locations allowing the condensation rate to be determined over the jet length. Test data have been obtained in a pure steam environment and with varying concentrations of noncondensable gas. This data extends the available jet condensation data from near atmospheric pressure up to a pressure of 1.7 MPa. An empirical correlation for the liquid side condensation heat transfer coefficient has been developed based on the data obtained in pure steam. The data obtained with noncondensable gas were used to develop a correlation for the renewal time as used in the condensation suppression model developed by Young and Bajorek. This paper describes a new sub-grid liquid jet
International Nuclear Information System (INIS)
Buschman, Francis X.; Aumiller, David L.
2017-01-01
Highlights: • Direct contact condensation data on liquid jets up to 1.7 MPa in pure steam and in the presence of noncondensable gas. • Identified a pressure effect on the impact of noncondensables to suppress condensation heat transfer not captured in existing data or correlations. • Pure steam data is used to develop a new correlation for condensation heat transfer on subcooled liquid jets. • Noncondensable data used to develop a modification to the renewal time estimate used in the Young and Bajorek correlation for condensation suppression in the presence of noncondensables. • A jet injection boundary condition, using a sub-grid jet condensation model, is developed for COBRA-IE which provides a more detailed estimate of the condensation rate on the liquid jet and allows the use of jet specific closure relationships. - Abstract: Condensation on liquid jets is an important phenomenon for many different facets of nuclear power plant transients and analyses such as containment spray cooling. An experimental facility constructed at the Pennsylvania State University, the High Pressure Liquid Jet Condensation Heat Transfer facility (HPLJCHT), has been used to perform steady-state condensation heat transfer experiments in which the temperature of the liquid jet is measured at different axial locations allowing the condensation rate to be determined over the jet length. Test data have been obtained in a pure steam environment and with varying concentrations of noncondensable gas. This data extends the available jet condensation data from near atmospheric pressure up to a pressure of 1.7 MPa. An empirical correlation for the liquid side condensation heat transfer coefficient has been developed based on the data obtained in pure steam. The data obtained with noncondensable gas were used to develop a correlation for the renewal time as used in the condensation suppression model developed by Young and Bajorek. This paper describes a new sub-grid liquid jet
Maintaining steam/condensate lines
International Nuclear Information System (INIS)
Russum, S.A.
1992-01-01
Steam and condensate systems must be maintained with the same diligence as the boiler itself. Unfortunately, they often are not. The water treatment program, critical to keeping the boiler at peak efficiency and optimizing operating life, should not stop with the boiler. The program must encompass the steam and condensate system as well. A properly maintained condensate system maximizes condensate recovery, which is a cost-free energy source. The fuel needed to turn the boiler feedwater into steam has already been provided. Returning the condensate allows a significant portion of that fuel cost to be recouped. Condensate has a high heat content. Condensate is a readily available, economical feedwater source. Properly treated, it is very pure. Condensate improves feedwater quality and reduces makeup water demand and pretreatment costs. Higher quality feedwater means more reliable boiler operation
Enhanced Condensation Heat Transfer
Rose, John Winston
The paper gives some personal observations on various aspects of enhanced condensation heat transfer. The topics discussed are external condensation (horizontal low-finned tubes and wire-wrapped tubes), internal condensation (microfin tubes and microchannels) and Marangoni condensation of binary mixtures.
Temporal dynamics of Bose-condensed gases
Energy Technology Data Exchange (ETDEWEB)
Trujillo Martinez, Mauricio
2014-03-19
We perform a detailed quantum dynamical study of non-equilibrium trapped, interacting Bose-condensed gases. We investigate Josephson oscillations between interacting Bose-Einstein condensates confined in a finite size double-well trap and the non-trivial time evolution of a coherent state placed at the center of a two dimensional optical lattice. For the Josephson oscillations three time scales appear. We find that Josephson junction can sustain multiple undamped oscillations up to a characteristic time scale τ{sub c} without exciting atoms out of the condensates. Beyond the characteristic time scale τ{sub c} the dynamics of the junction are governed by fast, non-condensed particles assisted Josephson tunnelling as well as the collisions between non-condensed particles. In the non-condensed particles dominated regime we observe strong damping of the oscillations due to inelastic collisions, equilibrating the system leading to an effective loss of details of the initial conditions. In addition, we predict that an initially self-trapped BEC state will be destroyed by these fast dynamics. The time evolution of a coherent state released at the center of a two dimensional optical lattice shows a ballistic expansion with a decreasing expansion velocity for increasing two-body interactions strength and particle number. Additionally, we predict that if the two-body interactions strength exceeds a certain value, a forerunner splits up from the expanding coherent state. We also observe that this system, which is prepared far from equilibrium, can evolve to a quasistationary non-equilibrium state.
Deepak Condenser Model (DeCoM)
Patel, Deepak
2013-01-01
Development of the DeCoM comes from the requirement of analyzing the performance of a condenser. A component of a loop heat pipe (LHP), the condenser, is interfaced with the radiator in order to reject heat. DeCoM simulates the condenser, with certain input parameters. Systems Improved Numerical Differencing Analyzer (SINDA), a thermal analysis software, calculates the adjoining component temperatures, based on the DeCoM parameters and interface temperatures to the radiator. Application of DeCoM is (at the time of this reporting) restricted to small-scale analysis, without the need for in-depth LHP component integrations. To efficiently develop a model to simulate the LHP condenser, DeCoM was developed to meet this purpose with least complexity. DeCoM is a single-condenser, single-pass simulator for analyzing its behavior. The analysis is done based on the interactions between condenser fluid, the wall, and the interface between the wall and the radiator. DeCoM is based on conservation of energy, two-phase equations, and flow equations. For two-phase, the Lockhart- Martinelli correlation has been used in order to calculate the convection value between fluid and wall. Software such as SINDA (for thermal analysis analysis) and Thermal Desktop (for modeling) are required. DeCoM also includes the ability to implement a condenser into a thermal model with the capability of understanding the code process and being edited to user-specific needs. DeCoM requires no license, and is an open-source code. Advantages to DeCoM include time dependency, reliability, and the ability for the user to view the code process and edit to their needs.
Optimizing condenser fan control for air-cooled centrifugal chillers
Energy Technology Data Exchange (ETDEWEB)
Yu, F.W.; Chan, K.T. [Dept. of Building Services Engineering, The Hong Kong Polytechnic Univ., Hung Hom, Hong Kong (China)
2008-07-15
The current design and operation of air-cooled condensers can cause a significant decrease in chiller performance under part load conditions. This paper demonstrates optimal condenser fan control to improve the coefficient of performance (COP) of air-cooled chillers. This control involves identifying the optimum set point of condensing temperature with the optimized power relationships of the compressors and condenser fans and enhancing the airflow and heat transfer area of the condensers. An example application of this control for an air-cooled centrifugal chiller indicated that the COP could increase by 11.4-237.2%, depending on the operating conditions. Such the increase of the COP results in a reduction of up to 14.1 kWh/m{sup 2}, or 27.3% in the annual electricity consumption per unit A/C floor area of chillers, given that the chillers serve an office building requiring an annual cooling energy per unit A/C floor area of 173.3 kWh/m{sup 2}. The simulation results of this study will give HVAC engineers a better understanding of how to optimize the design and operation of air-cooled chillers. (author)
Incorporation of Condensation Heat Transfer in a Flow Network Code
Anthony, Miranda; Majumdar, Alok
2002-01-01
Pure water is distilled from waste water in the International Space Station. The distillation assembly consists of an evaporator, a compressor and a condenser. Vapor is periodically purged from the condenser to avoid vapor accumulation. Purged vapor is condensed in a tube by coolant water prior to entering the purge pump. The paper presents a condensation model of purged vapor in a tube. This model is based on the Finite Volume Method. In the Finite Volume Method, the flow domain is discretized into multiple control volumes and a simultaneous analysis is performed.
Experimental study of EHD pseudo-dropwise condensation
International Nuclear Information System (INIS)
Yabe, A.; Taketani, T.; Yoshizawa, Y.; Sunada, K.
1991-01-01
This paper reports that in order to realize a higher performance heat pump, an electrohydrodynamical (EHD) condenser utilizing a combination of two kinds of EHD phenomena has been researched. In this study, to maximize the augmentation effect, an experimental study has been carried out to clarify the details of an EHD pseudo-dropwise condensation. The diameter of the drops has decreased with the increase of the electric field. The condensation heat transfer coefficients have increased in proportion to the electric field strength, realizing the maximum local heat transfer coefficients of over 9000 W/m 2 K for CFC113 and over 11000W/m 2 K for HCFC123. Furthermore, the heat transfer coefficients have become the same for the same electric field strength, independent of the surface temperature of the heat transfer plate, if the amount of the falling condensate is the same
Theory of laminar film condensation
Fujii, Tetsu
1991-01-01
Since the petroleum crisis in the 1970s, a lot of effort to save energy was made in industry, and remarkable achievements have been made. In the research and development concerning thermal energy, however, it was clar ified that one of the most important problems was manufacturing con densing systems with smaller size and higher performance. To solve this problem we need a method which synthesizes selections_ of the type of con denser, cooling tube and its arrangement, assessment of fouling on the cooling surfaces, consideration of transient characteristics of a condenser, etc. The majority of effort, however, has been to devise a surface element which enhances the heat transfer coefficient in condensation of a single or multicomponent vapor. Condensation phenomena are complexly affected by a lot of physical property values, and accordingly the results of theo retical research are expressed with several dimensionless parameters. On the other hand, the experimental research is limited to those with som...
International Nuclear Information System (INIS)
Wu, Jiafeng; Zhou, Jiahao; Chen, Yaping; Wang, Mingchao; Dong, Cong; Guo, Ya
2016-01-01
Highlights: • Trisection helical baffles are introduced for vertical condenser enhancement. • Condensation in short-section and intermediate drainage is applied in new schemes. • Helical baffles with liquid dam and drainage gaps can promote condenser performance. • Dual-thread baffle scheme is superior to that of single-thread one by about 19%. • Condensation enhancement ratio of helical schemes is 1.5–2.5 over segment one. - Abstract: The vertical condensers have advantages of small occupation area, convenient in assemble or dismantle tube bundle and simple structure etc. However, the low heat transfer performance limits their applications. To enhance the heat transfer, a novel type of vertical condensers was designed by introducing trisection helical baffles with liquid dams and gaps for facilitating condensate drainage. Four configurations of vertical condensers with trisection helical baffle are experimentally studied and compared to a traditional segment baffle condenser. The enhancement ratio of trisection helical baffle schemes is about 1.5–2.5 and the heat transfer coefficient of the dual-thread trisection helical baffle scheme is superior to that of the single-thread one by about 19%. Assistant by the theoretical study, the experimental data is simulated and the condensation enhancement mechanisms by applying trisection helical baffle in vertical condenser are summarized as condensate drainage, short tube construct and reduce steam dead zone functions of the helical baffles.
Nucleation and capture of condensible airborne contaminants in an aqueous scrubbing system
International Nuclear Information System (INIS)
Postma, A.K.; Hilliard, R.K.
1978-09-01
The fate of condensible contaminants in an aqueous scrubbing system was evaluated. Knowledge of the behavior of volatile fission product compounds is important in evaluating the effectiveness of emergency air cleaning systems proposed for use in containment systems of breeder reactor plants. When a high temperature air stream passes through a spray quench chamber, very large cooling rates occur in the drop boundary layers. These large cooling rates cause large supersaturations in airborne concentrations of condensible contaminants, and one predicts that most condensation would take place through homogeneous nucleation. The very small particles formed would agglomerate, and attach to sodium aerosol particles which would be present. In the study the overall removal efficiency of volatile fission product species (typified by NaI, SeO 2 , and Sb 2 O 3 ) in an air cleaning train (quench chamber, venturi scrubber, and fibrous bed) was theoretically evaluated. The overall removal efficiency of condensible materials was found to be lower than that for sodium compound aerosols because the freshly condensed particles would be smaller in size. For a base case, a removal efficiency of 99.97 percent was predicted for condensible materials. The fibrous bed scrubber exhibited superior particle removal characteristics for small particles compared to the quench chamber and venturi scrubber. Its removal efficiency exceeded 97 percent for even the most penetrating particle size (about 0.4 micron aerodynamic diameter). Therefore, all condensible fission products would be removed with efficiencies exceeding 97 percent
Performance evaluation of combined ejector LiBr/H2O absorption cooling cycle
Directory of Open Access Journals (Sweden)
Hasan Sh. Majdi
2016-03-01
Full Text Available The objective of this work is to develop a computer simulation program to evaluate the performance of solar-assited combined ejector absorption (single-effect cooling system using LiBr/H2O as a working fluid and operating under steady-state conditions. The ejector possess no moving parts and is simple and reliable, which makes it attractive for combination with single-stage absorption cycle for further improvement to the system's performance. In this research, improvement to the system is achieved by utilizing the potential kinetic energy of the ejector to enhance refrigeration efficiency. The effects of the entrainment ratio of the ejector, operating temperature, on the thermal loads, and system performance have been investigated. The results showed that the evaporator and condenser loads, post-addition of the ejector, is found to be permanently higher than that in the basic cycle, which indicates a significant enhancement of the proposed cycle and the cooling capacity of the system increasing with the increase in evaporator temperature and entrainment ratio. The COP of the modified cycle is improved by up to 60 % compared with that of the basic cycle at the given condition. This process stabilizes the refrigeration system, enhanced its function, and enabled the system to work under higher condenser temperatures.
Condensate polishing guidelines for PWR and BWR plants
International Nuclear Information System (INIS)
Robbins, P.; Crinigan, P.; Graham, B.; Kohlmann, R.; Crosby, C.; Seager, J.; Bosold, R.; Gillen, J.; Kristensen, J.; McKeen, A.; Jones, V.; Sawochka, S.; Siegwarth, D.; Keeling, D.; Polidoroff, T.; Morgan, D.; Rickertsen, D.; Dyson, A.; Mills, W.; Coleman, L.
1993-03-01
Under EPRI sponsorship, an industry committee, similar in form and operation to other guideline committees, was created to develop Condensate Polishing Guidelines for both PWR and BWR systems. The committee reviewed the available utility and water treatment industry experience on system design and performance and incorporated operational and state-of-the-art information into document. These guidelines help utilities to optimize present condensate polisher designs as well as be a resource for retrofits or new construction. These guidelines present information that has not previously been presented in any consensus industry document. The committee generated guidelines that cover both deep bed and powdered resin systems as an integral part of the chemistry of PWR and BWR plants. The guidelines are separated into sections that deal with the basis for condensate polishing, system design, resin design and application, data management and performance and management responsibilities
Modelling of a condenser-fan control for an air-cooled centrifugal chiller
International Nuclear Information System (INIS)
Yu, F.W.; Chan, K.T.
2007-01-01
There is a lack of detailed experimental and simulation studies on air-cooled centrifugal chillers. This paper investigates how to optimize the control of condenser fans within the chillers to maximize their coefficients of performance (COPs). A thermodynamic model for the chillers was developed and used to analyse the steady-state COP under various load and ambient conditions. An algorithm is introduced to compute the number of staged condenser fans based on settings of the condensing pressure and outdoor temperature. The model was validated using the experimental data and performance data of an existing chiller running under various operating conditions. It is found that the best strategy for switching condenser fans is to vary their rotating speed by the use of a set point of the condensing temperature, which is adjusted in response to the chiller load and condenser air-inlet temperature. The results of this paper provide an important insight into how to increase the COPs of air-cooled chillers
Modelling of a condenser-fan control for an air-cooled centrifugal chiller
Energy Technology Data Exchange (ETDEWEB)
Yu, F.W.; Chan, K.T. [Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)
2007-11-15
There is a lack of detailed experimental and simulation studies on air-cooled centrifugal chillers. This paper investigates how to optimize the control of condenser fans within the chillers to maximize their coefficients of performance (COPs). A thermodynamic model for the chillers was developed and used to analyse the steady-state COP under various load and ambient conditions. An algorithm is introduced to compute the number of staged condenser fans based on settings of the condensing pressure and outdoor temperature. The model was validated using the experimental data and performance data of an existing chiller running under various operating conditions. It is found that the best strategy for switching condenser fans is to vary their rotating speed by the use of a set point of the condensing temperature, which is adjusted in response to the chiller load and condenser air-inlet temperature. The results of this paper provide an important insight into how to increase the COPs of air-cooled chillers. (author)
Development of a condenser for the dual catalyst water recovery system
Budinikas, P.; Rasouli, F.; Rabadi, N.
1983-01-01
Conceptual evaporation/condensation systems suitable for integration with the catalytic water recovery method were evaluated. The primary requirements for each concept were its capability to operate under zero-gravity conditions, condense recovered water from a vapor-noncondensable gas mixture, and integrate with the catalytic system. Specific energy requirements were estimated for concepts meeting the primary requirements, and the concept most suitable for integration with the catalytic system was proposed. A three-man rate condenser capable of integration with the proposed system, condensing water vapor in presence of noncondensables and transferring the heat of condensation to feed urine was designed, fabricated, and tested. It was treated with steam/air mixtures at atmospheric and elevated pressures and integrated with an actual catalytic water recovery system. The condenser has a condensation efficiency exceeding 90% and heat transfer rate of approximately 85% of theoretical value at coolant temperature ranging from 7 to 80 deg C.
Minimum Leakage Condenser Test Program
International Nuclear Information System (INIS)
1978-05-01
This report presents the results and analysis of tests performed on four critical areas of large surface condensers: the tubes, tubesheets, tube/tubesheet joints and the water chambers. Significant changes in operation, service duty and the reliability considerations require that certain existing design criteria be verified and that improved design features be developed. The four critical areas were treated analytically and experimentally. The ANSYS finite element computer program was the basic analytical method and strain gages were used for obtaining experimental data. The results of test and analytical data are compared and recommendations made regarding potential improvement in condenser design features and analytical techniques
Utilization of air conditioner condenser as water heater in an effort to energy conservation
Sonawan, Hery; Saputro, Panji; Kurniawan, Iden Muhtar
2018-04-01
This paper presents an experimental study of utilization of air conditioner condenser as water heater. Modification of existing air conditioner system is an effort to harvest waste heat energy from condenser. Modification is conducted in order to test the system into two mode tests, first mode with one condenser and second mode with two condensers. Harvesting the waste heat from condenser needs a theoretical and practice study to see how much the AC performance changes if modifications are made. It should also be considered how the technique of harvesting waste heat for water heating purposes. From the problem, this paper presents a comparison between AC performance before and after modification. From the experiment, an increase in compressor power consumption is 4.3% after adding a new condenser. The hot water temperature is attained to 69 °C and ready for warm bath. The increase in power consumption is not too significant compared to the attainable hot water temperature. Also seen that the value of condenser Performance Factor increase from 5.8 to 6.25 or by 7.8%.
Assessment of Condenser Design in the Cooling System of PWR
International Nuclear Information System (INIS)
Sukmanto Dibyo
2008-01-01
This paper explains various cases related to the problem of condenser design principle. Condenser equipment is circuit component of cooling that is very important. Steam that goes down from the turbine, flowing to the condenser and the steam is condensate to be water. Step of design is beginning from identification of problem until mechanic design. Usually, the condenser is designed by conservative certain levels, as well as thermal aspect or mechanic. Beside that, the design analysis is also anticipated to the existing of degradation due to aging therefore safety aspect and requirement are accepted. The assessment that related to the condenser design has been discussed. Most important aspect is obtaining of performances. Beside that, the discussion is also described about design method and that complication should consider aspect of thermal design, physics, economic, aspect of corrosion and others factors. (author)
Vortices in trapped Bose-Einstein condensates
International Nuclear Information System (INIS)
Jackson, B.
2000-09-01
In this thesis we solve the Gross-Pitaevskii equation numerically in order to model the response of trapped Bose-Einstein condensed gases to perturbations by electromagnetic fields. First, we simulate output coupling of pulses from the condensate and compare our results to experiments. The excitation and separation of eigenmodes on flow through a constriction is also studied. We then move on to the main theme of this thesis: the important subject of quantised vortices in Bose condensates, and the relation between Bose-Einstein condensation and superfluidity. We propose methods of producing vortex pairs and rings by controlled motion of objects. Full three-dimensional simulations under realistic experimental conditions are performed in order to test the validity of these ideas. We link vortex formation to drag forces on the object, which in turn is connected with energy transfer to the condensate. We therefore argue that vortex formation by moving objects is intimately related to the onset of dissipation in superfluids. We discuss this idea in the context of a recent experiment, using simulations to provide evidence of vortex formation in the experimental scenario. Superfluidity is also manifest in the property of persistent currents, which is linked to vortex stability and dynamics. We simulate vortex line and ring motion, and find in both cases precessional motion and thermodynamic instability to dissipation. Strictly speaking, the Gross-Pitaevskii equation is valid only for temperatures far below the BEC transition. We end the thesis by describing a simple finite-temperature model to describe mean-field coupling between condensed and non-condensed components of the gas. We show that our hybrid Monte-Carlo/FFT technique can describe damping of the lowest energy excitations of the system. Extensions to this model and future research directions are discussed in the conclusion. (author)
International Nuclear Information System (INIS)
Kukulka, David J.; Smith, Rick; Li, Wei
2015-01-01
Results are presented here from an experimental investigation that was performed to evaluate the inside condensation and evaporation heat transfer of R410A, R22 and R32 that took place in a 12.7 mm (0.5 in) O.D. horizontal copper tube at low mass fluxes. Tubes considered in this evaluation consisted of a smooth tube (inner diameter 11.43 mm) and a newly developed enhanced surface Vipertex™ 1EHT tube. Heat transfer enhancement is an important factor in obtaining energy efficiency improvements in a variety of heat transfer applications. Utilization of enhanced heat transfer tubes is often utilized in the development of high performance air conditioning and refrigeration systems. Vipertex™ has designed and produced these surfaces through three dimensional material surface modifications which produces flow optimized, enhanced heat transfer tubes that increase heat transfer. Heat transfer enhancement plays an important role in improving energy efficiencies and developing high performance thermal systems. This study details the evaluation of the in-tube evaporation and condensation that takes place in these tubes over a wide range of conditions. The test apparatus utilized included a straight horizontal test section with an active length heated by water circulated in the surrounding annulus. Constant heat flux was maintained and refrigerant quality varied. In-tube evaporation measurements of R22, R32 and R410A are reported for evaporation at 10 °C with mass flow rates in the range of 15–40 kg h"−"1. Single phase measurements are reported for mass flow rates from 15 kg h"−"1 to 80 kg h"−"1. Condensation tests were conducted at a saturation temperature of 47 °C, with an inlet quality of 0.8 and an outlet quality of 0.1. In a comparison to smooth tubes, the average heat transfer coefficients for the Vipertex 1EHT tube exceeded those of a smooth tube. Average evaporation and condensation heat transfer coefficients for R22, R32 and R410A in the 1EHT
Bose–Einstein condensation in the Rindler space
Directory of Open Access Journals (Sweden)
Shingo Takeuchi
2015-11-01
Full Text Available Based on the Unruh effect, we calculate the critical acceleration of the Bose–Einstein condensation in a free complex scalar field at finite density in the Rindler space. Our model corresponds to an ideal gas performing constantly accelerating motion in a Minkowski space–time at zero-temperature, where the gas is composed of the complex scalar particles and it can be thought to be in a thermal-bath with the Unruh temperature. In the accelerating frame, the model will be in the Bose–Einstein condensation state at low acceleration; on the other hand, there will be no condensation at high acceleration by the thermal excitation brought into by the Unruh effect. Our critical acceleration is the one at which the Bose–Einstein condensation begins to appear in the accelerating frame when we decrease the acceleration gradually. To carry out the calculation, we assume that the critical acceleration is much larger than the mass of the particle.
Geysers advanced direct contact condenser research
Energy Technology Data Exchange (ETDEWEB)
Henderson, J.; Bahning, T.; Bharathan, D.
1997-12-31
The first geothermal application of the Advanced Direct Contact Condenser (ADCC) technology developed by the National Renewable Energy Laboratory (NREL) is now operational and is being tested at The Geysers Power Plant Unit 11. This major research effort is being supported through the combined efforts of NREL, The Department of Energy (DOE), and Pacific Gas and Electric (PG&E). NREL and PG&E have entered into a Cooperative Research And Development Agreement (CRADA) for a project to improve the direct-contact condenser performance at The Geysers Power Plant. This project is the first geothermal adaptation of an advanced condenser design developed for the Ocean Thermal Energy Conversion (OTEC) systems. PG&E expects this technology to improve power plant performance and to help extend the life of the steam field by using steam more efficiently. In accordance with the CRADA, no money is transferred between the contracting parties. In this case the Department of Energy is funding NREL for their efforts in this project and PG&E is contributing funds in kind. Successful application of this technology at The Geysers will provide a basis for NREL to continue to develop this technology for other geothermal and fossil power plant systems.
DEFF Research Database (Denmark)
Riaz, Muhammad; Kontogeorgis, Georgios; Stenby, Erling Halfdan
2011-01-01
,2-ethanediol (MEG) + condensate and MEG + water + condensate systems at temperatures from (275 to 323) K at atmospheric pressure. The condensate used in this work is a stabilized natural gas condensate from an offshore field in the North Sea. Compositional analysis of the natural gas condensate was carried out...... by gas chromatography, and detailed separation of individual condensate's components has been carried out. Approximately 85 peaks eluting before nonane were identified by their retention time. Peak areas were converted to mass fraction using 1-heptene as an internal standard. The components were divided...... into boiling range groups from hexane to nonane. Paraffinic (P), naphthenic (N), and aromatic (A) distributions were obtained for the boiling point fractions up to nonane. The average molar mass and the overall density of the condensate were measured experimentally. For the mutual solubility of MEG...
Hu, H. W.; Tang, G. H.; Niu, D.
2016-06-01
Recovery of both latent heat and condensate from boiler flue gas is significant for improving boiler efficiency and water conservation. The condensation experiments are carried out to investigate the simultaneous heat and mass transfer across the nanoporous ceramic membranes (NPCMs) which are treated to be hydrophilic and hydrophobic surfaces using the semicontinuous supercritical reactions. The effects of typical parameters including coolant flow rate, vapor/nitrogen gas mixture temperature, water vapor volume fraction and transmembrane pressure on heat and mass transfer performance are studied. The experimental results show that the hydrophilic NPCM exhibits higher performances of condensation heat transfer and condensate recovery. However, the hydrophobic modification results in remarkable degradation of heat and condensate recovery from the mixture. Molecular dynamics simulations are conducted to establish a hydrophilic/hydrophobic nanopore/water liquid system, and the infiltration characteristics of the single hydrophilic/hydrophobic nanopore is revealed.
Hu, H W; Tang, G H; Niu, D
2016-06-07
Recovery of both latent heat and condensate from boiler flue gas is significant for improving boiler efficiency and water conservation. The condensation experiments are carried out to investigate the simultaneous heat and mass transfer across the nanoporous ceramic membranes (NPCMs) which are treated to be hydrophilic and hydrophobic surfaces using the semicontinuous supercritical reactions. The effects of typical parameters including coolant flow rate, vapor/nitrogen gas mixture temperature, water vapor volume fraction and transmembrane pressure on heat and mass transfer performance are studied. The experimental results show that the hydrophilic NPCM exhibits higher performances of condensation heat transfer and condensate recovery. However, the hydrophobic modification results in remarkable degradation of heat and condensate recovery from the mixture. Molecular dynamics simulations are conducted to establish a hydrophilic/hydrophobic nanopore/water liquid system, and the infiltration characteristics of the single hydrophilic/hydrophobic nanopore is revealed.
Guo, Yonghong; Du, Xiaoze; Yang, Lijun
2018-02-01
Air-cooled condenser is the main equipment of the direct dry cooling system in a power plant, which rejects heat of the exhaust steam with the finned tube bundles. Therefore, the thermo-flow performances of the finned tubes have an important effect on the optimal operation of the direct dry cooling system. In this paper, the flow and heat transfer characteristics of the single row finned tubes with the conventional flat fins and novel jagged fins are investigated by numerical method. The flow and temperature fields of cooling air for the finned tubes are obtained. Moreover, the variations of the flow resistance and average convection heat transfer coefficient under different frontal velocity of air and jag number are presented. Finally, the correlating equations of the friction factor and Nusselt number versus the Reynolds number are fitted. The results show that with increasing the frontal velocity of air, the heat transfer performances of the finned tubes are enhanced but the pressure drop will increase accordingly, resulting in the average convection heat transfer coefficient and friction factor increasing. Meanwhile, with increasing the number of fin jag, the heat transfer performance is intensified. The present studies provide a reference in optimal designing for the air-cooled condenser of direct air cooling system.
Numerical Study of Condensation Heat Exchanger Design in a Cooling jacket: Correlation Investigation
International Nuclear Information System (INIS)
Kim, Myoung Jun; Lee, Hee Joon; Kang, Han Ok; Lee, Tae Ho; Park, Cheon Tae
2013-01-01
In this study, condensing heat transfer correlation of TSCON is evaluated with the existing experimental data set to design condensation heat exchanger without noncondensable gas effect (pure steam condensation) in a cooling jacket. From the investigation of the existing condensation heat transfer correlation to the existing experimental data, the improved Shah's correlation showed most satisfactory result for the condensation heat transfer coefficient with experimental data of Khun in a cooling jacket, whereas the Shah's correlation with experimental data of Lee. Lee et al. reported the improved Shah correlation gave us the best predictor for the condensation heat transfer data of Kim and Henderson in a subcooled and saturated water pool. They suggested the improved Shah correlation should be adopted as condensation heat transfer module in TSCON(Thermal Sizing of CONdenser) to design condensation heat exchanger in secondary passive cooling system of nuclear plant
Aldol Condensation of Citral with Acetone on Basic Solid Catalysts
Directory of Open Access Journals (Sweden)
NODA C.
1998-01-01
Full Text Available The catalytic performance of solids with basic properties, such as CaO, MgO and hydrotalcites, was evaluated in the aldol condensation of citral and acetone, the first step in the synthesis of ionones from citral. The best results were obtained with CaO and hydrotalcite with high conversions (98% and selectivities (close to 70% for the main product observed for both of the catalyst. Such pseudoionone yields were greater than those reported in the literature for the homogeneous reaction.
Cho, Jaeyong; Lee, Joonsang
2017-11-01
The condensation is the one of the efficient heat transfer phenomenon that transfers the heat along an interface between two phases. This condensation is affected by the wettability of surface. Heat transfer rate can be improved by controlling the wettability of surface. Recently, the researches with patterned wettability, which is composed by a combination of hydrophilic and hydrophobic surface, have been performed to improve the heat transfer rate of condensation. In this study, we performed numerical simulation for condensation of droplet on the patterned wettability, and we analyze condensation phenomenon on the wettability pattered surface through the kinetic energy, heat flux curve, and droplet shape in the vicinity of the droplet. When we performed numerical simulations and analyzing the condensation with patterned wettability, we used the lattice Boltzmann method for the base model, and phase change was solved by Peng-Robinson equation of sate. We can find that the droplet is generated at the bottom surface and high condensation rate can be maintained on the patterned wettability. This work was also supported by the National Research Foundation of Korea (NRF) Grant funded by the Korean Government (MSIP) (No. 2015R1A5A1037668) and BrainKorea21plus.
High-efficiency free-form condenser overcoming rotational symmetry limitations.
Miñano, Juan C; Benítez, Pablo; Blen, José; Santamaría, Asunción
2008-12-08
Conventional condensers using rotational symmetric devices perform far from their theoretical limits when transferring optical power from sources such as arc lamps or halogen bulbs to the rectangular entrance of homogenizing prisms (target). We present a free-form condenser design (calculated with the SMS method) that overcomes the limitations inherent to rotational devices and can send to the target 1.8 times the power sent by an equivalent elliptical condenser for a 4:1 target aspect ratio and 1.5 times for 16:9 target and for practical values of target etendue.
Dry coolers and air-condensing units (Review)
Milman, O. O.; Anan'ev, P. A.
2016-03-01
The analysis of factors affecting the growth of shortage of freshwater is performed. The state and dynamics of the global market of dry coolers used at electric power plants are investigated. Substantial increase in number and maximum capacity of air-cooled condensers, which have been put into operation in the world in recent years, are noted. The key reasons facilitating the choice of developers of the dry coolers, in particular the independence of the location of thermal power plant from water sources, are enumerated. The main steam turbine heat removal schemes using air cooling are considered, their comparison of thermal efficiency is assessed, and the change of three important parameters, such as surface area of heat transfer, condensate pump flow, and pressure losses in the steam exhaust system, are estimated. It is shown that the most effective is the scheme of direct steam condensation in the heat-exchange tubes, but other schemes also have certain advantages. The air-cooling efficiency may be enhanced much more by using an air-cooling hybrid system: a combination of dry and wet cooling. The basic applied constructive solutions are shown: the arrangement of heat-exchange modules and the types of fans. The optimal mounting design of a fully shopassembled cooling system for heat-exchange modules is represented. Different types of heat-exchange tubes ribbing that take into account the operational features of cooling systems are shown. Heat transfer coefficients of the plants from different manufacturers are compared, and the main reasons for its decline are named. When using evaporative air cooling, it is possible to improve the efficiency of air-cooling units. The factors affecting the faultless performance of dry coolers (DC) and air-condensing units (ACU) and the ways of their elimination are described. A high velocity wind forcing reduces the efficiency of cooling systems and creates preconditions for the development of wind-driven devices. It is noted that
International Nuclear Information System (INIS)
Corvin, C.
1995-06-01
A synchronous condenser is a synchronous machine that generates reactive power that leads real power by 90 degrees in phase. The leading reactive power generated by the condenser offsets or cancels the normal lagging reactive power consumed by inductive and nonlinear loads at the accelerator complex. The quality of SLAC's utility power is improved with the addition of the condenser. The inertia of the condenser's 35,000 pound rotor damps and smoothes voltage excursions on two 12 kilovolt master substation buses, improving voltage regulation site wide. The condenser absorbs high frequency transients and noise in effect ''scrubbing'' the electric system power at its primary distribution source. In addition, the condenser produces a substantial savings in power costs. Federal and investor owned utilities that supply electric power to SLAC levy a monthly penalty for lagging reactive power delivered to the site. For the 1993 fiscal year this totaled over $285,000 in added costs for the year. By generating leading reactive power on site, thereby reducing total lagging reactive power requirements, a substantial savings in electric utility bills is achieved. Actual savings of $150,000 or more a year are possible depending on experimental operations
Artificial neural network analysis of a refrigeration system with an evaporative condenser
Energy Technology Data Exchange (ETDEWEB)
Ertunc, H.M. [Department of Mechatronics Engineering, Kocaeli University, 41040 Kocaeli (Turkey); Hosoz, M. [Department of Mechanical Education, Kocaeli University, 41380 Kocaeli (Turkey)
2006-04-01
This paper describes an application of artificial neural networks (ANNs) to predict the performance of a refrigeration system with an evaporative condenser. In order to gather data for training and testing the proposed ANN, an experimental refrigeration system with an evaporative condenser was set up. Then, steady-state test runs were conducted varying the evaporator load, air and water flow rates passing through the condenser and both dry and wet bulb temperatures of the air stream entering the condenser. Utilizing some of the experimental data, an ANN model for the system based on standard backpropagation algorithm was developed. The ANN was used for predicting various performance parameters of the system, namely the condenser heat rejection rate, refrigerant mass flow rate, compressor power, electric power input to the compressor motor and the coefficient of performance. The ANN predictions usually agree well with the experimental values with correlation coefficients in the range of 0.933-1.000, mean relative errors in the range of 1.90-4.18% and very low root mean square errors. Results show that refrigeration systems, even complex ones involving concurrent heat and mass transfer such as systems with an evaporative condenser, can alternatively be modelled using ANNs within a high degree of accuracy. [Author].
Conditions for maximum isolation of stable condensate during separation in gas-condensate systems
Energy Technology Data Exchange (ETDEWEB)
Trivus, N.A.; Belkina, N.A.
1969-02-01
A thermodynamic analysis is made of the gas-liquid separation process in order to determine the relationship between conditions of maximum stable condensate separation and physico-chemical nature and composition of condensate. The analysis was made by considering the multicomponent gas-condensate fluid produced from Zyrya field as a ternary system, composed of methane, an intermediate component (propane and butane) and a heavy residue, C/sub 6+/. Composition of 5 ternary systems was calculated for a wide variation in separator conditions. At each separator pressure there is maximum condensate production at a certain temperature. This occurs because solubility of condensate components changes with temperature. Results of all calculations are shown graphically. The graphs show conditions of maximum stable condensate separation.
International Nuclear Information System (INIS)
Bandurski, T.; Huggenberger, M.; Dreier, J.; Aubert, C.; Putz, F.; Gamble, R.E.; Yadigaroglu, G.
2001-01-01
Recently, passive cooling systems have been designed for the long-term decay heat removal from the containment of Advanced Light Water Reactors. In particular, the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric European Simplified Boiling Water Reactor (ESBWR) has been tested in the large scale PANDA facility. The PANDA tests achieved the dual objective of improving confidence in the performance of the passive heat removal mechanisms underlying the design of the tested systems and extending the data base available for containment analysis code qualification. The tests conducted subject the PCCS to a variety of conditions representing design-basis and beyond-design-basis accident conditions. These include operation in the presence of both heavier and lighter than steam noncondensible gases as well as a variety of asymmetric conditions and challenging start-up conditions. The present paper addresses the transient distribution of noncondensibles and their effect on the passive condenser performance in PANDA
Energy Technology Data Exchange (ETDEWEB)
Bandurski, T. E-mail: thomas.bandurski@psi.ch; Huggenberger, M.; Dreier, J.; Aubert, C.; Putz, F.; Gamble, R.E. E-mail: robert.gamble@gene.ge.com; Yadigaroglu, G. E-mail: yadigaroglu@iet.mavt.ethz.ch
2001-02-01
Recently, passive cooling systems have been designed for the long-term decay heat removal from the containment of Advanced Light Water Reactors. In particular, the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric European Simplified Boiling Water Reactor (ESBWR) has been tested in the large scale PANDA facility. The PANDA tests achieved the dual objective of improving confidence in the performance of the passive heat removal mechanisms underlying the design of the tested systems and extending the data base available for containment analysis code qualification. The tests conducted subject the PCCS to a variety of conditions representing design-basis and beyond-design-basis accident conditions. These include operation in the presence of both heavier and lighter than steam noncondensible gases as well as a variety of asymmetric conditions and challenging start-up conditions. The present paper addresses the transient distribution of noncondensibles and their effect on the passive condenser performance in PANDA.
A Robust, Gravity-Insensitive, High-Temperature Condenser for Water Recovery
Chen, Weibo; Conboy, Thomas; Ewert, Michael
2016-01-01
Regenerative life support systems are vital for NASA's future long-duration human space exploration missions. A Heat Melt Compactor (HMC) system is being developed by NASA to dry and compress trash generated during space missions. The resulting water vapor is recovered and separated from the process gas flow by a gravity-insensitive condenser. Creare is developing a high-temperature condenser for this application. The entire condenser is constructed from metals that have excellent resistance to chemical attack from contaminants and is suitable for high-temperature operation. The metal construction and design configuration also offer greatest flexibility for potential coating and regeneration processes to reduce biofilm growth and thus enhancing the reliability of the condenser. The proposed condenser builds on the gravity-insensitive phase separator technology Creare developed for aircraft and spacecraft applications. This paper will first discuss the design requirements for the condenser in an HMC system that will be demonstrated on the International Space Station (ISS). Then, it will present the overall design of the condenser and the preliminary thermal test results of a subscale condenser. Finally, this paper will discuss the predicted performance of the full-size condenser and the development plan to mature the technology and enhance its long-term reliability for a flight system.
Numerical Study of Condensation Heat Exchanger Design in a Cooling jacket: Correlation Investigation
Energy Technology Data Exchange (ETDEWEB)
Kim, Myoung Jun; Lee, Hee Joon [Kookmin Univ., Seoul (Korea, Republic of); Kang, Han Ok; Lee, Tae Ho; Park, Cheon Tae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
2013-10-15
In this study, condensing heat transfer correlation of TSCON is evaluated with the existing experimental data set to design condensation heat exchanger without noncondensable gas effect (pure steam condensation) in a cooling jacket. From the investigation of the existing condensation heat transfer correlation to the existing experimental data, the improved Shah's correlation showed most satisfactory result for the condensation heat transfer coefficient with experimental data of Khun in a cooling jacket, whereas the Shah's correlation with experimental data of Lee. Lee et al. reported the improved Shah correlation gave us the best predictor for the condensation heat transfer data of Kim and Henderson in a subcooled and saturated water pool. They suggested the improved Shah correlation should be adopted as condensation heat transfer module in TSCON(Thermal Sizing of CONdenser) to design condensation heat exchanger in secondary passive cooling system of nuclear plant.
International Nuclear Information System (INIS)
Stevanovic, V.D.; Stosic, Z.V.; Stoll, U.
2005-01-01
In this paper the radiolytic gases (hydrogen and oxygen) accumulation is investigated numerically for the pipe geometry consisting of a horizontal pipe closed at one end, and connected via a downward directed elbow with a vertical pipe open at its bottom end. This configuration is a typical part of many pipeline systems or measuring lines. The steam inside the pipes is condensed due to heat losses to the surrounding atmosphere, the condensate is drained and the concentration of the remaining noncondensable radiolytic gases is increased. Three dimensional numerical simulations are performed with the thermal-hydraulic and physico-chemical code HELIO, especially developed for the simulation and analyses of radiolytic gases accumulation in pipelines. The HELIO code model is based on the mass, momentum and energy conservation equations for the gas mixture and wall condensate film flow, as well as on the transport equations for non-condensable diffusion and convection. At the liquid film surface, the phases are coupled through the no-slip velocity condition and the mass transfer due to steam condensation and non-condensable absorption and degassing. Obtained numerical results show the gas mixture and condensate liquid film flow fields. In case of here analyzed geometry, the gas mixture circulates in the elbow and the horizontal pipe due to buoyancy forces induced by concentration and related density differences. The circulation flow prevents the formation of the radiolytic gases concentration front. The non-condensable radiolytic gases are transported from the pipe through the open end by the mechanisms of diffusion and convection. The analyzed geometry is the same as in case of venting pipe mounted on the steam pipeline. The results are of practical importance since they show that radiolytic gases accumulation does not occur in the geometry of the venting pipes. (authors)
Directory of Open Access Journals (Sweden)
Ali Maisarah
2016-01-01
Full Text Available Ventilation systems play a significant role in maintaining the indoor thermal and hygric balance. Nevertheless, the systems had been implicated to result in many problems. In the tropical climate, especially for energy efficiency purposes, building spaces are operated with differential ventilation. Such spaces operate on 24-hrs basis, some on 8-hrs while others are either naturally ventilated or served with mechanical supply-exhaust fan systems with non-conditioned outdoor air. This practice had been found to result in condensation problems. This study involves a quantitative appraisal of the effect of operative conditions and hygrothermal quality of building envelopes on condensation risk. The in-situ experiment is combined with an analytical approach to assessing the hygrothermal quality of building envelopes in a tropical climate building under differential ventilation between adjacent spaces. The case-studied building is with a known history of condensation and associated damages including mould growth. The microclimate measurement and hygrothermal performance of the wall and floor against condensation and mould growth risks had been previously reported elsewhere. As a step further, the present study evaluates the effects of various envelope insulation types and configurations together with the HVAC cooling set-points on envelope hygrothermal performance. The results revealed that overcooling the air-conditioned side increases condensation risk on the non-air-conditioned side of the envelopes. The envelopes failed criteria for surface condensation at existing operative conditions irrespective of envelope hygrothermal quality improvements. However, the envelope performed well at improved cooling operative conditions even at existing envelope hygrothermal quality. It is, therefore, important to ascertain the envelope hygrothermal quality as well the cooling operative conditions while embarking on energy efficiency operations in mechanical
International Nuclear Information System (INIS)
Yılmaz, İbrahim Halil; Saka, Kenan; Kaynakli, Omer
2016-01-01
One of the parameters affecting the COP of the absorption system can be considered as the thermal balance between the high pressure condenser (HPC) and the low pressure generator (LPG) since heat rejected from the HPC is utilized as an energy source by the LPG. Condensation of the water vapor in the HPC depends on the heat removal via the LPG. This circumstance is significant for making an appropriate design and a controllable system with high performance in practical applications. For this reason, a thermodynamic analysis for the HPC of a double effect series flow water/lithium bromide absorption refrigeration system was emphasized in this study. A simulation was developed to investigate the energy transfer between the HPC and LPG. The results show that the proper designation of the HPC temperature improves the COP and ECOP due its significant impact, and its value necessarily has to be higher than the outlet temperature of the LPG based on the operating scheme. Furthermore, the COP and ECOP of the absorption system can be raised in the range of 9.72–35.09% in case of 2 °C-temperature increment in the HPC under the described conditions to be applied. - Highlights: • Thermal balance in HPC/LPG unit of a double effect absorption system was studied. • A simulation program was developed and its outputs were validated. • A parametric study was conducted for a wide range of component temperatures. • Proper designation of the HPC temperature improves the COP and ECOP. • The system performance raised 9.72–35.09% by controlling the HPC temperature.
1975-01-01
During 1975 the SC2 performance was improved among other things by redesigning some of the elements of the ROTCO (Annual Report 1975, p. 55). The photo shows an interior wiew of the housing of the rotary condenser and of the sixteen sets of shaped stator blades.
R.Hussain Vali; P.Yagnasri; S.Naresh Kumar Reddy
2016-01-01
Vapor compression machine is a refrigerator in which the heat removed from the cold by evaporation of the refrigerant is given a thermal potential so that it can gravitate to a natural sink by compressing the vapor produced. Majority of the refrigerators works on the Vapor compression refrigeration system. The system consists of components like compressor, condenser, expansion valve and evaporator. The performance of the system depends on the performance of all the components of the system. ...
Evaluation of sea water chlorine demand in condenser cooling water at TAPS 1 and 2
International Nuclear Information System (INIS)
Papachan, Deepa; Gupta, P.K.; Patil, D.P.; Save, C.B.; Anilkumar, K.R.
2008-01-01
To prevent microbiological growth in the condenser tubes, condenser cooling water chlorination is very important. For effective chlorination, chlorine dose rate and frequency of dosing has to be determined on the basis of sea water chlorine demand. TAPS 1 and 2 is located near Arabian sea and draws water from this sea for its condenser cooling. The present practice of chlorine dosing at TAPS 1 and 2, based on the analysis carried out by GE in 1969, is 2500 kg/day/CWpump and 90 kg/day/SSWpump for a contact period of 25 minutes. Normal frequency of dosing is once per 8 hour and booster dose is once in a week at the same rate for 1 hour. The criteria of effective chlorination is to get residual chlorine of 2-3 ppm at the condenser water box outlet during chlorination at water box inlet/CW pump suction header in the recommended dose rate. The other option of chlorination was continuous dosing to get 0.5 ppm residual chlorine. This option has its own limitations as it is more expensive and also that micro organisms get immune to chlorine eventually due to continuous dosing. Nevertheless higher chlorine dosing is detrimental to AI-brass condenser tubes. Therefore the second option was not adopted at TAPS 1 and 2. Tarapur Atomic Power Station-1 is in the process of replacement of condenser tubes due to frequent condenser tube failures in the recent years. It was essential to analyse the present sea water chlorine demand and re-determine the chlorine dose rate because of development of industries under Maharashtra Industrial Development Corporation (MIDC) and simultaneous population growth around this area over a period of three decades. This paper discusses the experimental observations regarding significant change in sea water chlorine demand over this period and the effect of seasonal changes on sea water chlorine demand. (author)
Purification method for condensate
International Nuclear Information System (INIS)
Shimoda, Akiyoshi.
1996-01-01
Condensates generated in secondary coolant circuits of a PWR type reactor are filtered using a hollow thread separation membranes comprising aromatic polyether ketone. Preferably, condensates after passing through a turbine are filtered at a place between a condensator and a steam generator at high temperature as close as a temperature of the steam generator. As the hollow thread membrane, partially crystalline membrane comprising aromatic polyether ketone is used. When it is used at high temperature, the crystallinity is preferably not less than 15wt%. Since a hollow thread membrane comprising the aromatic polyether ketone of excellent heat resistance is used, it can filter and purify the condensates at not lower than 70degC. Accordingly, impurities such as colloidal iron can be removed from the condensates, and the precipitation of cruds in the condensates to a steam generator and a turbine can be suppressed. (I.N.)
Prediction of BWR performance under the influence of Isolation Condenser-using RAMONA-4 code
International Nuclear Information System (INIS)
Khan, H.J.; Cheng, H.S.; Rohatgi, U.S.
1992-01-01
The purpose of the Boiling Water Reactor (BWR) Isolation Condenser (IC) is to passively control the reactor pressure by removing heat from the system. This type of control is expected to reduce the frequency of opening and closing of the Safety Relief Valves (SRV). A comparative analysis is done for a BWR operating with and without the influence of an IC under Main Steam Isolation Valve (MSIV) closure. A regular BWR, with forced flow and high thermal power, has been considered for analysis. In addition, the effect of ICs on the BWR performance is studied for natural convection flow at lower power and modified riser geometry. The IC is coupled to the steam dome for the steam inlet flow and the Reactor Pressure Vessel (RPV) near the feed water entrance for the condensate return flow. Transient calculations are performed using prescribed pressure set points for the SRVs and given time settings for MSIV closure. The effect of the IC on the forced flow is to reduce the rate of pressure rise and thereby decrease the cycling frequency ofthe SRVS. This is the primary objective of any operating IC in a BWR (e.g. Oyster Creek). The response of the reactor thermal and fission power, steam flow rate, collapsed liquid level, and core average void fraction are found to agree with the trend of pressure. The variations in the case of an active IC can be closely related to the creation of a time lag and changes in the cycling frequency of the SRVS. An analysis for natural convection flow in a BWR indicates that the effect of an IC on its transient performance is similar to that for the forced convection system. In this case, the MSIV closure, has resulted in a lower peak pressure due to the magnitude of reduced power. However, the effect of reduced cycling frequency of the SRV due to the IC, and the time lag between the events, are comparable to that for forced convection
Application of evaporative cooling on the condenser of window-air-conditioner
International Nuclear Information System (INIS)
Hajidavalloo, Ebrahim
2007-01-01
Reduction of energy consumption is a major concern in the vapor compression refrigeration cycle especially in the area with very hot weather conditions (about 50 deg. C), where window-air-conditioners are usually used to cool homes. In this weather condition performance of air condenser window-air-conditioners decrease sharply and electrical power consumption increase considerably. These problems have activated the research programs in order to improve the performance of window-air-conditioners by enhancing heat transfer rate in the condenser. In this article, a new design with high commercialization potential for incorporating of evaporative cooling in the condenser of window-air-conditioner is introduced and experimentally investigated. A real air conditioner is used to test the innovation by putting two cooling pads in both sides of the air conditioner and injecting water on them in order to cool down the air before it passing over the condenser. The experimental results show that thermodynamic characteristics of new system are considerably improved and power consumption decreases by about 16% and the coefficient of performance increases by about 55%
Application of evaporative cooling on the condenser of window-air-conditioner
Energy Technology Data Exchange (ETDEWEB)
Hajidavalloo, Ebrahim [Shahid Chamran University, Department of Mechanical Engineering, Golestan St., Ahwaz, Khoozestan 61355 (Iran, Islamic Republic of)]. E-mail: hajidae_1999@yahoo.com
2007-08-15
Reduction of energy consumption is a major concern in the vapor compression refrigeration cycle especially in the area with very hot weather conditions (about 50 deg. C), where window-air-conditioners are usually used to cool homes. In this weather condition performance of air condenser window-air-conditioners decrease sharply and electrical power consumption increase considerably. These problems have activated the research programs in order to improve the performance of window-air-conditioners by enhancing heat transfer rate in the condenser. In this article, a new design with high commercialization potential for incorporating of evaporative cooling in the condenser of window-air-conditioner is introduced and experimentally investigated. A real air conditioner is used to test the innovation by putting two cooling pads in both sides of the air conditioner and injecting water on them in order to cool down the air before it passing over the condenser. The experimental results show that thermodynamic characteristics of new system are considerably improved and power consumption decreases by about 16% and the coefficient of performance increases by about 55%.
Field tests of 2- and 40-tube condensers at the East Mesa Geothermal Test Site
Energy Technology Data Exchange (ETDEWEB)
Murphy, R.W.; Domingo, N.
1982-05-01
Two water-cooled isobutane condensers, one with 2 tubes and one with 40 tubes, were subjected to field tests at the East Mesa Geothermal Test Site to assess relative heat transfer performance in both surface evaporator and direct-contact evaporator modes. The five groups of tests established that field performance was below earlier laboratory-determined levels and that direct-contact evaporator mode performance was poorer than that for the surface evaporator mode. In all test situations, fluted condenser tubes performed better than smooth condenser tubes. Cooling water quality had no significant effect on performance, but brine preflash in the direct-contact mode did promote some relative performance improvement. Important implications of these results for binary geothermal power plants are that (1) working-fluid-side impurities can significantly degrade heat transfer performance of the power plant condensers and (2) provisions for minimizing such impurities may be required.
Energy Technology Data Exchange (ETDEWEB)
Choi, Dong jae; Jang, Yeong jun; Lee, Yeon-Gun [Jeju National University, Jeju (Korea, Republic of); Kim, Sin [Chung-Ang University, Seoul (Korea, Republic of)
2015-10-15
The Passive Containment Cooling System (PCCS) to be introduced in advanced LWRs removes released energy to an external heat sink by a naturally driven flow. Containment through the condensation heat transfer phenomenon in the event of the loss of coolant accident (LOCA) or main steam line break (MSLB). As the released steam pressurizes the containment, the PCCS will activate to transport the decay heat In this study, a numerical analysis of the condensation heat transfer coefficients on the PCCS condenser tube is conducted using the MARS-KS code. The condensation heat transfer coefficients are obtained from JNU condensation tests performed on a 1000 long and 40 mm O.D. tube. The analysis condition covers 2 and 4 bar for the air mass fraction ranging from 0.1 to 0.8. The JNU single vertical condensation experimental results, Uchida's and Dehbi's correlation compared with the MARS-KS code's results at 2 and 4 bar. Experimental results and MARS-KS predicted heat transfer coefficient is different from the thermal resistances and Wall subcooling. An average relative error is 18.8% and 15% at 2 and 4 bar, respectively. Uchida's correlation is considered the noncondensable gas mass fraction only. Therefore, that is lower than MARS-KS results at 4 bar. Dehbi's correlation affected by ratio of the height-to-diameter, so its results are higher condensation heat transfer coefficient than MARS-KS predicted results.
Effect of condensed tannins addition on the astringency of red wines.
Soares, Susana; Sousa, André; Mateus, Nuno; de Freitas, Victor
2012-02-01
Astringency has been defined as a group of sensations involving dryness, tightening, and shrinking of the oral surface. It has been accepted that astringency is due to the tannin-induced interaction and/or precipitation of the salivary proline-rich proteins (PRPs) in the oral cavity, as a result of the ingestion of food products rich in tannins, for example, red wine. The sensory evaluation of astringency is difficult, and the existence of fast and reliable methods to its study in vitro is scarce. So, in this work, the astringency of red wine supplemented with oligomeric procyanidins (condensed tannins), and the salivary proteins (SP) involved in its development were evaluated by high-performance liquid chromatography analysis of human saliva after its interaction with red wine and by sensorial evaluation. The results show that for low concentration of tannins, the decrease of acidic PRPs and statherin is correlated with astringency intensity, with these families having a high relative complexation and precipitation toward condensed tannins comparatively to the other SP. However, for higher concentrations of tannins, the relative astringency between wines seems to correlate's to the glycosylated PRPs changes. This work shows for the first time that the several families of SP could be involved in different stages of the astringency development.
International Nuclear Information System (INIS)
Pineda Gomez, Cesar Augusto; Arenas Mantilla, Oscar Armando; Santos Santos, Nicolas
2007-01-01
For transporting industry of natural gas by pipeline systems, it's vital to guarantee the integrity of their lines, in order to decrease operational costs and prevent accidents that may damaging against people's safety, the environment or the infrastructure itself. in this paper it's presented the principal compounds from o technical study about principal net and its distribution branches to municipalities of the National System Transport of Natural Gas pointed by the Colombian Natural Gas Company - ECOGAS, (specifically the Cusiana - Porvenir - La Belleza, La Belleza - Cogua, La Belleza - Vasconia, Vasconia - Neiva and Vasconia - Cali gas lines, (see Figure 1). The principal objective is evaluate the possible condensation of hydrocarbons fluids inside gas lines, due to compositional characteristics of the gas, the different topographical conditions along the gas line route and the actual and future operational conditions to be implemented in the system. The evaluation performed over this gas streams, generates transcendental information in the creation of safe operational limits that minimizing the existence of obstacle problems and damages over pipeline systems and process equipment, due to the presence of liquid hydrocarbons inside these flow lines. This article has been prepared in four sections in order to guarantee easy access to each one of the steps involved in the study. Section one presents the compositional and thermodynamic analysis of feeding gas streams; in section two, its presented the required information for modeling gas lines with definition of the gas pipeline numerical simulation model in stable state; section three presents the sensitivity analysis for gas variation upon loading gas composition at the inlet point of the system, variation of the operational conditions (flow, pressure and gas temperature) and environment temperatures for the different inlet points (branches) with verification of compliance of the Unique Transport Regulation
Energy Technology Data Exchange (ETDEWEB)
Cachard, F. de; Lomperski, S.; Monauni, G.R. [Paul Scherrer Inst. (PSI), Villigen (Switzerland). Lab. for Thermal-Hydraulics
1999-07-01
An experimental and analytical program was performed at PSI to study the performance of a finned-tube condenser in the presence of non-condensable gases at low gas mass fluxes. The model developed for this application includes mixed convection heat transfer between the vapour/non-condensable mixture and the finned-tubes, heat conduction through the fins and tubes, and evaporative heat transfer inside the tubes. The finned-tubes condenser model has been assessed against data obtained at the PSI LINX facility with two test condensers. For the 62 LINX experiments performed, the model predictions are very good, i.e., less than 10 % standard deviation between experimental and predicted results. (authors)
Analytical model for power plant condenser for transients and off-normal operating conditions
International Nuclear Information System (INIS)
Thangamani, I.; Dutta, Anu; Chakraborty, G.; Ghosh, A.K.
2006-11-01
A computer code for power plant condenser dynamic analysis has been developed based on a lumped parameter approach considering time dependent mass and energy conservation equations over the control volumes for the shell side as well as tube side fluids. Effects of heat transfer on condenser structure and hot well level transients were considered in the analysis. Suitable heat transfer coefficient recommended by various standards and codes were employed. The code was used to analyze the condenser performance during steady state as well as transient (load rejection or turbine trip) conditions. The condenser performance is predicted in terms of condenser back pressure, shell side steam temperature and tube side coolant exit temperature with respect to time. As a part of parametric studies, the effect of change in tube side coolant flow rate and inlet temperature was also studied. The analysis predicted that up to 47% of rated coolant flow rate on the tube side (for design conditions), the steam dumping can be continued without condenser isolation. The paper describes the detailed methodology adopted for the condenser modeling and presents the results obtained from the different parametric studies and code validation. (author)
Practical integrated design of a condenser-objective lens for transmission electron microscope
International Nuclear Information System (INIS)
Li Wenping; Wu Jian; Zhou Zhen; Gui Lijiang; Han Li
2009-01-01
A condenser-objective lens is designed through combination of separating and integrating to consider the effect of the front condenser field on its objective performance. A practical lens model including magnetic pole piece, magnetic circuit and coil windings is built to optimize its rear field. The front field can be integrated into the rear one by simply adjusting the position of the specimen and the excitation on the condenser-objective lens. Optical performance of the integrated lens is researched as both a condenser lens and an imaging one. The total aberrations at the specimen plane are 0.01nm under STEM operation mode and its spherical aberration coefficient is 1.5mm when being an imaging objective lens, which can meet for high resolution microanalysis and TEM imaging.
Dimensioning of emergency condensers in accordance with safety requirements
Energy Technology Data Exchange (ETDEWEB)
Palavecino, C [SIEMENS, Energieerzeugung, Offenbach (Germany)
1996-12-01
The emergency condensers are heat exchangers consisting of a parallel arrangement of horizontal U-tubes between two common heads. The tope header is connected via piping to the reactor vessel steam space, while the lower header is connected to the reactor vessel below the reactor vessel water level. The heat exchangers are located in a pool filled with cold water. The emergency condensers and the reactor vessel thus form a system of communicating pipes. At normal reactor water level, the emergency condensers are flooded with cold, non-flowing water. No heat transfer takes place in this condition. If there is a drop in the reactor water level, the heat exchanging surfaces are gradually uncovered and the incoming steam condenses on the cold surfaces. The cold condensate in returned to the reactor vessel. In this way, heat is removed from the reactor vessel and water simultaneously supplied to the reactor vessel. This means that the emergency condensers function as a heat removal system while at the same time serving as HP and LP coolant injection systems. The emergency condensers operate with the highest possible degree of passivity imaginable, namely through a drop in the reactor vessel water level alone, requiring neither control systems nor power supply. The design of the emergency condensers must meet the requirements dictated by the thermal and the hydraulic conditions. Taking into consideration a redundancy degree of N + 2, a specific thermal rating of 63 MW per emergency condenser results for a reactor with an output of 2778 MW. The total performance of the emergency condenser system in thus 252 MW, or 9.1% of reactor output. The probability of failure of the emergency condenser of Siemens SWR 1000 is approximately 10{sup -4} per demand, while that of the older emergency condenser designs is approximately 2 to 3 x 10{sup -3} per demand. (author). 7 figs, 2 tabs.
International Nuclear Information System (INIS)
Ravva, Srinivasa Rao; Iyer, Kannan N.; Gupta, S.K.; Gaikwad, Avinash J.
2014-01-01
Highlights: • A condensation model based on diffusion was implemented in FLUENT. • Validation of a condensation model for the H 2 distribution studies was performed. • Multi-component diffusion is used in the present work. • Appropriate grid and turbulence model were identified. - Abstract: This paper aims at the implementation details of a condensation model in the CFD code FLUENT and its validation so that it can be used in performing the containment hydrogen distribution studies. In such studies, computational fluid dynamics simulations are necessary for obtaining accurate predictions. While steam condensation plays an important role, commercial CFD codes such as FLUENT do not have an in-built condensation model. Therefore, a condensation model was developed and implemented in the FLUENT code through user defined functions (UDFs) for the sink terms in the mass, momentum, energy and species balance equations together with associated turbulence quantities viz., kinetic energy and dissipation rate. The implemented model was validated against the ISP-47 test of TOSQAN facility using the standard wall functions and enhanced wall treatment approaches. The best suitable grid size and the turbulence model for the low density gas (He) distribution studies are brought out in this paper
Condensation shocks in high momentum two-phase flows in condensing injectors
International Nuclear Information System (INIS)
Anand, G.; Christensen, R.N.
1993-01-01
This study presents a phenomenological and mathematical model of condensation shocks in high momentum two-phase flows in condensing injectors. The characteristics of the shock were related to the mode of vapor bubble collapse. Using cavitation terminology, the bubble collapse can be classified as inertially controlled or thermally controlled. Inertial bubble collapse occurs rapidly whereas, a thermally controlled collapse results in a significantly longer collapse time. The interdependence between the bubble collapse mode and the momentum and pressure of the flow, was analyzed in this study. For low-temperature-high-velocity flows a steep pressure rise with complete condensation was obtained. For a high-temperature-low velocity flow with noncondensables, low pressure recovery with incomplete condensation was observed. These trends are in agreement with previous experimental observations
Sedimentary condensation and authigenesis
Föllmi, Karl
2016-04-01
Most marine authigenic minerals form in sediments, which are subjected to condensation. Condensation processes lead to the formation of well individualized, extremely thin ( 100ky), and which experienced authigenesis and the precipitation of glaucony, verdine, phosphate, iron and manganese oxyhydroxides, iron sulfide, carbonate and/or silica. They usually show complex internal stratigraphies, which result from an interplay of sediment accumulation, halts in sedimentation, sediment winnowing, erosion, reworking and bypass. They may include amalgamated faunas of different origin and age. Hardgrounds may be part of condensed beds and may embody strongly condensed beds by themselves. Sedimentary condensation is the result of a hydrodynamically active depositional regime, in which sediment accumulation, winnowing, erosion, reworking and bypass are processes, which alternate as a function of changes in the location and intensity of currents, and/or as the result of episodic high-energy events engendered by storms and gravity flow. Sedimentary condensation has been and still is a widespread phenomenon in past and present-day oceans. The present-day distribution of glaucony and verdine-rich sediments on shelves and upper slopes, phosphate-rich sediments and phosphorite on outer shelves and upper slopes, ferromanganese crusts on slopes, seamounts and submarine plateaus, and ferromanganese nodules on abyssal seafloors is a good indication of the importance of condensation processes today. In the past, we may add the occurrence of oolitic ironstone, carbonate hardgrounds, and eventually also silica layers in banded iron formations as indicators of the importance of condensation processes. Besides their economic value, condensed sediments are useful both as a carrier of geochemical proxies of paleoceanographic and paleoenvironmental change, as well as the product of episodes of paleoceanographic and paleoenvironmental change themselves.
International Nuclear Information System (INIS)
Han, Kyu Il; Cho, Dong Hyun
2005-01-01
This study concerns the performance of condensing heat transfer in two-phase closed thermosyphons with various helical grooves. Distilled water, methanol, ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The type of working fluid and the numbers of grooves of the thermosyphons with various helical grooves have been used as the experimental parameters. The experimental results have been assessed and compared with existing theories. The results show that the type of working fluids are very important factors for the operation of thermosyphons. And the maximum enhancement (i.e. the ratio of the heat transfer coefficients the helical thermosyphons to plain thermosyphons) is 1.5∼2 for condensation
Evaporation and condensation at a liquid methanol surface
Matsumoto, Mitsuhiro; Yasuoka, Kenji; Kataoka, Yosuke
1994-07-01
The dynamics of evaporation and condensation at a flat liquid surface of methanol were studied under the liquidvapor equilibrium condition at room temperature with molecular dynamics computer simulation techniques. Analysis of molecular trajectories shows that the condensation coefficient is 89%. It suggests that only a tenth of incident vapor molecules are reflected at the liquid surface, contrary to a prediction of a classical transition state theory. To investigate the potential barrier of the evaporation-condensation process, a particle insertion method was applied and the local chemical potential near the surface was evaluated. The calculated chemical potential is constant in the whole region including the surface layer and no potential barrier is observed in the vincinity of the surface, which casts strong doubt on the explanation of a transition state theory.
Electret filter collects more exhaled albumin than glass condenser
Jia, Ziru; Liu, Hongying; Li, Wang; Xie, Dandan; Cheng, Ke; Pi, Xitian
2018-01-01
Abstract In recent years, noninvasive diagnosis based on biomarkers in exhaled breath has been extensively studied. The procedure of biomarker collection is a key step. However, the traditional condenser method has low efficacy in collecting nonvolatile compounds especially the protein biomarkers in breath. To solve this deficiency, here we propose an electret filter method. Exhaled breath of 6 volunteers was collected with a glass condenser and an electret filter. The amount of albumin was analyzed. Furthermore, the difference of exhaled albumin between smokers and nonsmokers was evaluated. The electret filter method collected more albumin than the glass condenser method at the same breath volume level (P albumin than nonsmokers were also observed (P albumin than nonsmokers. PMID:29384875
Heat Transfer Enhancement During Water and Hydrocarbon Condensation on Lubricant Infused Surfaces.
Preston, Daniel J; Lu, Zhengmao; Song, Youngsup; Zhao, Yajing; Wilke, Kyle L; Antao, Dion S; Louis, Marcel; Wang, Evelyn N
2018-01-11
Vapor condensation is routinely used as an effective means of transferring heat or separating fluids. Dropwise condensation, where discrete droplets form on the condenser surface, offers a potential improvement in heat transfer of up to an order of magnitude compared to filmwise condensation, where a liquid film covers the surface. Low surface tension fluid condensates such as hydrocarbons pose a unique challenge since typical hydrophobic condenser coatings used to promote dropwise condensation of water often do not repel fluids with lower surface tensions. Recent work has shown that lubricant infused surfaces (LIS) can promote droplet formation of hydrocarbons. In this work, we confirm the effectiveness of LIS in promoting dropwise condensation by providing experimental measurements of heat transfer performance during hydrocarbon condensation on a LIS, which enhances heat transfer by ≈450% compared to an uncoated surface. We also explored improvement through removal of noncondensable gases and highlighted a failure mechanism whereby shedding droplets depleted the lubricant over time. Enhanced condensation heat transfer for low surface tension fluids on LIS presents the opportunity for significant energy savings in natural gas processing as well as improvements in thermal management, heating and cooling, and power generation.
Steam condensation process in a power production cycle and heat exchanger for it
International Nuclear Information System (INIS)
Tondeur, Gerard; Andro, Jean; Marjollet, Jacques; Pouderoux, Pierre.
1982-01-01
Steam condensation process in a power production cycle by expansion in turbines, characterized by the fact that this condensation is performed by the vaporization of a coolant with a vaporization temperature at atmospheric pressure lower than that of water, and that the vaporized coolant fluid is expanded in a turbine and then condensed by heat exchange with cold water being heated, while the liquefied coolant is recompressed and used for heat exchange with the steam to be condensed [fr
Computations of steam flow and heat transfer in nuclear power plant condensers
International Nuclear Information System (INIS)
Yuan, A.
1997-01-01
To improve performance of its PWR nuclear power plants, Electricite de France has developed a performance monitoring system that checks simultaneously the operation of the components of the secondary system. The performance monitoring system is based on a computational software CITER for steady state runs. A one-dimensional condenser model has been developed. Application of this code to a nuclear power plant condenser shows that predicted values in good agreement with the design values
Numerical analysis of the influence of circuit arrangement on a fin-and-tube condenser performance
Directory of Open Access Journals (Sweden)
Cesare Maria Joppolo
2015-09-01
Full Text Available In the present paper a model for the steady-state simulation of fin-and-tube condenser is developed. The model is based on a finite volume approach that divides each tube into small elemental volumes where mass, momentum and energy conservation equations are solved using the effectiveness-NTU method and with appropriate correlations for void fraction, friction factor and heat transfer coefficient calculation. The model is validated against experimental data on two small condensers finding that the calculated heat transfer rate and refrigerant-side pressure drop agree within ±5% and ±21% respectively to the experimental values. The model is then used to numerically analyse the impact of different circuit arrangements on the condenser heat transfer rate, refrigerant-side pressure drop and refrigerant charge.
Nahra, Henry K.; Hall, Nancy R.; Hasan, Mohammad M.; Wagner, James D.; May, Rochelle L.; Mackey, Jeffrey R.; Kolacz, John S.; Butcher, Robert L.; Frankenfield, Bruce J.; Mudawar, Issam;
2013-01-01
Flow boiling and condensation have been identified as two key mechanisms for heat transport that are vital for achieving weight and volume reduction as well as performance enhancement in future space systems. Since inertia driven flows are demanding on power usage, lower flows are desirable. However, in microgravity, lower flows are dominated by forces other than inertia (like the capillary force). It is of paramount interest to investigate limits of low flows beyond which the flow is inertial enough to be gravity independent. One of the objectives of the Flow Boiling and Condensation Flight Experiment sets to investigate these limits for flow boiling and condensation. A two-phase flow loop consisting of a Flow Boiling Module and two Condensation Modules has been developed to experimentally study flow boiling condensation heat transfer in the reduced gravity environment provided by the reduced gravity platform. This effort supports the development of a flow boiling and condensation facility for the International Space Station (ISS). The closed loop test facility is designed to deliver the test fluid, FC-72 to the inlet of any one of the test modules at specified thermodynamic and flow conditions. The zero-g-aircraft tests will provide subcooled and saturated flow boiling critical heat flux and flow condensation heat transfer data over wide range of flow velocities. Additionally, these tests will verify the performance of all gravity sensitive components, such as evaporator, condenser and accumulator associated with the two-phase flow loop. We will present in this paper the breadboard development and testing results which consist of detailed performance evaluation of the heater and condenser combination in reduced and normal gravity. We will also present the design of the reduced gravity aircraft rack and the results of the ground flow boiling heat transfer testing performed with the Flow Boiling Module that is designed to investigate flow boiling heat transfer and
Condensing Unit with a Scroll Compressor (UB series)
Energy Technology Data Exchange (ETDEWEB)
Editor, [Korea Energy Management Corporation, Yongin (Korea)
2002-05-01
Condensing unit, which is selected as a heat reservoir of grocery store or refrigerating warehouse, has increased its electricity consumption due to high annual operating ratio and large-sized stores. As the requirement of temperature management on freezing and storage has become strict for maintenance of food quality, the number of companies that import HACCP has increased for a few years. Accordingly, the requirement of high performance and reliability on a condensing unit has also risen more than it did. To meet the requirement, Mitsubishi Electric developed and sold condensing unit UB series, which has high reliability in energy saving. The company also has a plan to sell UPB series for the substitute refrigerant gas from fall of 2001. 5 figs., 2 tabs.
An Efficient Implementation of Partial Condensing for Nonlinear Model Predictive Control
DEFF Research Database (Denmark)
Frison, Gianluca; Kouzoupis, Dimitris; Jørgensen, John Bagterp
2016-01-01
-horizon trade-off is investigated from a theoretical point of view (based on algorithms flop count) as well as by benchmarking (in practice, the performance of linear algebra routines for different matrix sizes plays a key role). Partial condensing can also be seen as a technique to replace many operations...... on small matrices with fewer operations on larger matrices, where linear algebra routines perform better. Therefore, in case of small-scale MPC problems, partial condensing can greatly improve performance beyond the flop count reduction....
Method and apparatus for high-efficiency direct contact condensation
Bharathan, Desikan; Parent, Yves; Hassani, A. Vahab
1999-01-01
A direct contact condenser having a downward vapor flow chamber and an upward vapor flow chamber, wherein each of the vapor flow chambers includes a plurality of cooling liquid supplying pipes and a vapor-liquid contact medium disposed thereunder to facilitate contact and direct heat exchange between the vapor and cooling liquid. The contact medium includes a plurality of sheets arranged to form vertical interleaved channels or passageways for the vapor and cooling liquid streams. The upward vapor flow chamber also includes a second set of cooling liquid supplying pipes disposed beneath the vapor-liquid contact medium which operate intermittently in response to a pressure differential within the upward vapor flow chamber. The condenser further includes separate wells for collecting condensate and cooling liquid from each of the vapor flow chambers. In alternate embodiments, the condenser includes a cross-current flow chamber and an upward flow chamber, a plurality of upward flow chambers, or a single upward flow chamber. The method of use of the direct contact condenser of this invention includes passing a vapor stream sequentially through the downward and upward vapor flow chambers, where the vapor is condensed as a result of heat exchange with the cooling liquid in the contact medium. The concentration of noncondensable gases in the resulting condensate-liquid mixtures can be minimized by controlling the partial pressure of the vapor, which depends in part upon the geometry of the vapor-liquid contact medium. In another aspect of this invention, the physical and chemical performance of a direct contact condenser can be predicted based on the vapor and coolant compositions, the condensation conditions. and the geometric properties of the contact medium.
Topflow-experiments on direct condensation and bubble entrainment. Technical report
International Nuclear Information System (INIS)
Seidel, Tobias; Lucas, Dirk; Beyer, Matthias
2016-01-01
Direct Contact Condensation between steam and water as well as bubble entrainment below the water surface play an important role in different accident scenarios for light water reactors. One example is the emergency core cooling water injection into a two-phase mixture. It has to be considered for example to evaluate potential pressurized thermal shock phenomena. This report documents experiments conducted in flat basin inside the TOPFLOW pressure chamber aiming on the generation of a database useful for CFD model development and validation. It comprises 3 different setups: condensation at a stratified flow of sub-cooled water, condensation at a sub-cooled water jet and a combination of both phenomena with steam bubble entrainment. The documentation includes all details on the experimental set up, on experimental conditions (experimental matrices), on the conduction of the experiments, on measuring techniques used and on data evaluation procedures. In addition, selected results are presented.
Evaporation and condensation heat transfer with a noncondensable gas present
International Nuclear Information System (INIS)
Murase, M.; Kataoka, Y.; Fujii, T.
1993-01-01
To evaluate the system pressure of an external water wall type containment vessel, which is one of the passive systems for containment cooling, the evaporation and condensation behavior under a noncondensable gas presence has been experimentally examined. In the system, steam evaporated from the suppression pool surface into the wetwell, filled with noncondensable gas, and condensed on the containment vessel wall. The system pressure was the sum of the noncondensable gas pressure and saturated steam pressure in the wetwell. The wetwell temperature was, however, lower than the suppression pool temperature and depended on the thermal resistance on the suppression pool surface. The evaporation and condensation heat transfer coefficients in the presence of air as noncondensable gas were measured and expressed by functions of steam/air mass ratio. The evaporation heat transfer coefficients were one order higher than the condensation heat transfer coefficients because the local noncondensable gas pressure was much lower on the evaporating pool surface than on the condensing liquid surface. Using logal properties of the heat transfer surfaces, there was a similar trend between evaporation and condensation even with a noncondensable gas present. (orig.)
Research progress of control of condensate depression for condenser
Liu, Ying; Liang, Run; Li, Fengyu
2017-08-01
It is introduced that significance and structure of the condensate depression control system. In accordance with controller devised procedure, we analyze and elaborate how to construct the lumped parameter and dynamic mathematical model which possesses distinct physics significance. Neural network model being called black-box model is also introduced. We analyze and contrast the control technique of condensate depression as conventional PI control, fuzzy PI control and fuzzy control. It is indicated that if the controller of condensate depression were devised inappropriate, while the steam discharged of turbine varying by a large margin, would result in the rotation rate of cooling water circulating pump accelerating at a great lick even to trigger the galloping danger which is less impressive for the units operating safely.
Universal Themes of Bose-Einstein Condensation
Proukakis, Nick P.; Snoke, David W.; Littlewood, Peter B.
2017-04-01
Foreword; List of contributors; Preface; Part I. Introduction: 1. Universality and Bose-Einstein condensation: perspectives on recent work D. W. Snoke, N. P. Proukakis, T. Giamarchi and P. B. Littlewood; 2. A history of Bose-Einstein condensation of atomic hydrogen T. Greytak and D. Kleppner; 3. Twenty years of atomic quantum gases: 1995-2015 W. Ketterle; 4. Introduction to polariton condensation P. B. Littlewood and A. Edelman; Part II. General Topics: Editorial notes; 5. The question of spontaneous symmetry breaking in condensates D. W. Snoke and A. J. Daley; 6. Effects of interactions on Bose-Einstein condensation R. P. Smith; 7. Formation of Bose-Einstein condensates M. J. Davis, T. M. Wright, T. Gasenzer, S. A. Gardiner and N. P. Proukakis; 8. Quenches, relaxation and pre-thermalization in an isolated quantum system T. Langen and J. Schmiedmayer; 9. Ultracold gases with intrinsic scale invariance C. Chin; 10. Berezinskii-Kosterlitz-Thouless phase of a driven-dissipative condensate N. Y. Kim, W. H. Nitsche and Y. Yamamoto; 11. Superfluidity and phase correlations of driven dissipative condensates J. Keeling, L. M. Sieberer, E. Altman, L. Chen, S. Diehl and J. Toner; 12. BEC to BCS crossover from superconductors to polaritons A. Edelman and P. B. Littlewood; Part III. Condensates in Atomic Physics: Editorial notes; 13. Probing and controlling strongly correlated quantum many-body systems using ultracold quantum gases I. Bloch; 14. Preparing and probing chern bands with cold atoms N. Goldman, N. R. Cooper and J. Dalibard; 15. Bose-Einstein condensates in artificial gauge fields L. J. LeBlanc and I. B. Spielman; 16. Second sound in ultracold atomic gases L. Pitaevskii and S. Stringari; 17. Quantum turbulence in atomic Bose-Einstein condensates N. G. Parker, A. J. Allen, C. F. Barenghi and N. P. Proukakis; 18. Spinor-dipolar aspects of Bose-Einstein condensation M. Ueda; Part IV. Condensates in Condensed Matter Physics: Editorial notes; 19. Bose
Assessment of TRACE Condensation Model Against Reflux Condensation Tests with Noncondensable Gases
Energy Technology Data Exchange (ETDEWEB)
Lee, Kyung Won; Cheong, Ae Ju; Shin, Andong; Suh, Nam Duk [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)
2015-05-15
The TRACE is the latest in a series of advanced, best-estimated reactor systems code developed by U.S. Nuclear Regulatory Commission for analyzing transient and steady-state neutronic-thermal-hydraulic behavior in light water reactors. This special model is expected to replace the default model in a future code release after sufficient testing has been completed. This study assesses the special condensation model of TRACE 5.0-patch4 against the counter-current flow configuration. For this purpose, the predicted results of special model are compared to the experimental and to those of default model. The KAST reflux condensation test with NC gases are used in this assessment. We assessed the special model for film condensation of TRACE 5.0-patch4 against the data of the reflux condensation test in the presence of NC gases. The special condensation model of TRACE provides a reasonable estimate of HTC with good agreement at the low inlet steam flow rate.
Assessment of TRACE Condensation Model Against Reflux Condensation Tests with Noncondensable Gases
International Nuclear Information System (INIS)
Lee, Kyung Won; Cheong, Ae Ju; Shin, Andong; Suh, Nam Duk
2015-01-01
The TRACE is the latest in a series of advanced, best-estimated reactor systems code developed by U.S. Nuclear Regulatory Commission for analyzing transient and steady-state neutronic-thermal-hydraulic behavior in light water reactors. This special model is expected to replace the default model in a future code release after sufficient testing has been completed. This study assesses the special condensation model of TRACE 5.0-patch4 against the counter-current flow configuration. For this purpose, the predicted results of special model are compared to the experimental and to those of default model. The KAST reflux condensation test with NC gases are used in this assessment. We assessed the special model for film condensation of TRACE 5.0-patch4 against the data of the reflux condensation test in the presence of NC gases. The special condensation model of TRACE provides a reasonable estimate of HTC with good agreement at the low inlet steam flow rate
Experimental study of condensate subcooling with the use of a model of an air-cooled condenser
Sukhanov, V. A.; Bezukhov, A. P.; Bogov, I. A.; Dontsov, N. Y.; Volkovitsky, I. D.; Tolmachev, V. V.
2016-01-01
Water-supply deficit is now felt in many regions of the world. This hampers the construction of new steam-turbine and combined steam-and-gas thermal power plants. The use of dry cooling systems and, specifically, steam-turbine air-cooled condensers (ACCs) expands the choice of sites for the construction of such power plants. The significance of condensate subcooling Δ t as a parameter that negatively affects the engineering and economic performance of steam-turbine plants is thereby increased. The operation and design factors that influence the condensate subcooling in ACCs are revealed, and the research objective is, thus, formulated properly. The indicated research was conducted through physical modeling with the use of the Steam-Turbine Air-Cooled Condenser Unit specialized, multipurpose, laboratory bench. The design and the combined schematic and measurement diagram of this test bench are discussed. The experimental results are presented in the form of graphic dependences of the condensate subcooling value on cooling ratio m and relative weight content ɛ' of air in steam at the ACC inlet at different temperatures of cooling air t ca ' . The typical ranges of condensate subcooling variation (4 ≤ Δ t ≤ 6°C, 2 ≤ Δ t ≤ 4°C, and 0 ≤ Δ t ≤ 2°C) are identified based on the results of analysis of the attained Δ t levels in the ACC and numerous Δ t reduction estimates. The corresponding ranges of cooling ratio variation at different temperatures of cooling air at the ACC inlet are specified. The guidelines for choosing the adjusted ranges of cooling ratio variation with account of the results of experimental studies of the dependences of the absolute pressure of the steam-air mixture in the top header of the ACC and the heat flux density on the cooling ratio at different temperatures of cooling air at the ACC inlet are given.
Condensation of steam in horizontal pipes: model development and validation
International Nuclear Information System (INIS)
Szijarto, R.
2015-01-01
This thesis submitted to the Swiss Federal Institute of Technology ETH in Zurich presents the development and validation of a model for the condensation of steam in horizontal pipes. Condensation models were introduced and developed particularly for the application in the emergency cooling system of a Gen-III+ boiling water reactor. Such an emergency cooling system consists of slightly inclined horizontal pipes, which are immersed in a cold water tank. The pipes are connected to the reactor pressure vessel. They are responsible for a fast depressurization of the reactor core in the case of accident. Condensation in horizontal pipes was investigated with both one-dimensional system codes (RELAP5) and three-dimensional computational fluid dynamics software (ANSYS FLUENT). The performance of the RELAP5 code was not sufficient for transient condensation processes. Therefore, a mechanistic model was developed and implemented. Four models were tested on the LAOKOON facility, which analysed direct contact condensation in a horizontal duct
Evaluation on the thermal-hydraulic behavior of condensation pool and piping system
Energy Technology Data Exchange (ETDEWEB)
Kwon, Soon Bum; Lee, B. E.; Baek, S. C.; Joo, S. Y.; Lee, D. E.; Woo, S. W. [Kyungpook National Univ., Daegu (Korea, Republic of)
2002-03-15
The In-containment Refueling Water Storage Tank (IRWST) has the function of heat sink, when steam is released from the pressurizer. The hydrodynamic behaviors occurring at the piping system and sparger are very complex because of the wide variety of operating conditions and the complex geometry. Hydrodynamic behavior when air is discharged through a sparger in a condensation pool is investigated using CFD techniques in the present study. The effect of pressure acting on the sparger header during both water and air discharge through the sparger is studied. In addition, pressure oscillation occurring in the IRWST during air discharge through the sparger is studied for a better understanding of mechanisms of air discharge md an advanced evaluation technology of reactor safety. Understanding of flow behaviors occurring m the various types of pipes when POSRV is opened are also very important because those are very complex and may damage the structures of reactor coolant system. The principle of shock tube has been applied to analyze flow behaviors occurring in the piping system and several important phenomena which can be used for the evaluation of nuclear reactor safety has been obtained.
Birbarah, Patrick; Li, Zhaoer; Pauls, Alexander; Miljkovic, Nenad
2015-07-21
Superhydrophobic micro/nanostructured surfaces for dropwise condensation have recently received significant attention due to their potential to enhance heat transfer performance by shedding positively charged water droplets via coalescence-induced droplet jumping at length scales below the capillary length and allowing the use of external electric fields to enhance droplet removal and heat transfer, in what has been termed electric-field-enhanced (EFE) jumping-droplet condensation. However, achieving optimal EFE conditions for enhanced heat transfer requires capturing the details of transport processes that is currently lacking. While a comprehensive model has been developed for condensation on micro/nanostructured surfaces, it cannot be applied for EFE condensation due to the dynamic droplet-vapor-electric field interactions. In this work, we developed a comprehensive physical model for EFE condensation on superhydrophobic surfaces by incorporating individual droplet motion, electrode geometry, jumping frequency, field strength, and condensate vapor-flow dynamics. As a first step toward our model, we simulated jumping droplet motion with no external electric field and validated our theoretical droplet trajectories to experimentally obtained trajectories, showing excellent temporal and spatial agreement. We then incorporated the external electric field into our model and considered the effects of jumping droplet size, electrode size and geometry, condensation heat flux, and droplet jumping direction. Our model suggests that smaller jumping droplet sizes and condensation heat fluxes require less work input to be removed by the external fields. Furthermore, the results suggest that EFE electrodes can be optimized such that the work input is minimized depending on the condensation heat flux. To analyze overall efficiency, we defined an incremental coefficient of performance and showed that it is very high (∼10(6)) for EFE condensation. We finally proposed mechanisms
Condensation: the new deal; Condensation: la nouvelle donne
Energy Technology Data Exchange (ETDEWEB)
NONE
2002-06-01
The principle of condensation boilers is based on the recovery of the latent heat of the steam generated by the combustion of natural gas. This technology was introduced in France at the end of the 80's but failed in its promise because of the complexity of the equipments available at that time. Today, constructors' offer is more mature and reliable and the context has changed. This technology can conciliate three goals: a mastery of energy consumptions, the comfort of the user and the respect of environment. This meeting organized by the research center of Gaz de France (Cegibat), was a good opportunity to makes a status of the market of individual condensation systems in France and in Europe, to present the situation of this technology today and the 10 golden rules for the fitting and maintenance of individual condensation boilers, and to present some technical references, examples and results of today's offer. (J.S.)
Numerical model of sprayed air cooled condenser coupled to refrigerating system
International Nuclear Information System (INIS)
Youbi-Idrissi, M.; Macchi-Tejeda, H.; Fournaison, L.; Guilpart, J.
2007-01-01
Because of technological, economic and environmental constraints, many refrigeration and air conditioning units are equipped with a simple air cooled condenser. Spraying the condenser seems to be an original solution to improve the energetic performances of such systems. To characterise this energetic benefit, a semi-local mathematical model was developed and applied to a refrigerating machine with and without spraying its air cooled condenser. It is found that, compared to a dry air cooled condenser, both the calorific capacity and machine COP increase by 13% and 55%, respectively. Furthermore, the model shows that a spray flow rate threshold occurs. It should not be exceeded to assure an effective and rational spray use
Condensation irrigation a system for desalination and irrigation
International Nuclear Information System (INIS)
Lindblom, J.; Nordell, B
2006-01-01
condensation irrigation is a system for both desalination and irrigation. The principles is that humidified air is let into an underground horizontal pipe system, where the air is cooled by the ground and humidity falls out as fresh water. The humidification could e.g. be achieved by evaporation of seawater in solar stills or any other heat source. By using drainage pipes for underground air transportation the water percolates into the soil, thereby irrigating the land. This study focuses on drinking water production, which means that humid air is led into plan pipes where the condensed water is collected at the pipe endings. Numerical simulations gave a study-state diurnal mean water production of 1.8 kg per meter of pipe over a 50 m pipe. Shorter pipes result in a greater mean production rate. Since the heat transfer of drainage pipes would be greater, current study indicates that condensation irrigation is a promising method for desalination and irrigation. Performed studies in condensation irrigation started at LTU in 2003. Current paper reports the initial theoretical work on the system.(Author)
Mathematical simulation of the process of condensing natural gas
Tastandieva G.M.
2015-01-01
Presents a two-dimensional unsteady model of heat transfer in terms of condensation of natural gas at low temperatures. Performed calculations of the process heat and mass transfer of liquefied natural gas (LNG) storage tanks of cylindrical shape. The influence of model parameters on the nature of heat transfer. Defined temperature regimes eliminate evaporation by cooling liquefied natural gas. The obtained dependence of the mass flow rate of vapor condensation gas temperature. Identified the...
Transonic flow of steam with non-equilibrium and homogenous condensation
Virk, Akashdeep Singh; Rusak, Zvi
2017-11-01
A small-disturbance model for studying the physical behavior of a steady transonic flow of steam with non-equilibrium and homogeneous condensation around a thin airfoil is derived. The steam thermodynamic behavior is described by van der Waals equation of state. The water condensation rate is calculated according to classical nucleation and droplet growth models. The current study is based on an asymptotic analysis of the fluid flow and condensation equations and boundary conditions in terms of the small thickness of the airfoil, small angle of attack, closeness of upstream flow Mach number to unity and small amount of condensate. The asymptotic analysis gives the similarity parameters that govern the problem. The flow field may be described by a non-homogeneous transonic small-disturbance equation coupled with a set of four ordinary differential equations for the calculation of the condensate mass fraction. An iterative numerical scheme which combines Murman & Cole's (1971) method with Simpson's integration rule is applied to solve the coupled system of equations. The model is used to study the effects of energy release from condensation on the aerodynamic performance of airfoils operating at high pressures and temperatures and near the vapor-liquid saturation conditions.
Born-Kothari Condensation for Fermions
Directory of Open Access Journals (Sweden)
Arnab Ghosh
2017-09-01
Full Text Available In the spirit of Bose–Einstein condensation, we present a detailed account of the statistical description of the condensation phenomena for a Fermi–Dirac gas following the works of Born and Kothari. For bosons, while the condensed phase below a certain critical temperature, permits macroscopic occupation at the lowest energy single particle state, for fermions, due to Pauli exclusion principle, the condensed phase occurs only in the form of a single occupancy dense modes at the highest energy state. In spite of these rudimentary differences, our recent findings [Ghosh and Ray, 2017] identify the foregoing phenomenon as condensation-like coherence among fermions in an analogous way to Bose–Einstein condensate which is collectively described by a coherent matter wave. To reach the above conclusion, we employ the close relationship between the statistical methods of bosonic and fermionic fields pioneered by Cahill and Glauber. In addition to our previous results, we described in this mini-review that the highest momentum (energy for individual fermions, prerequisite for the condensation process, can be specified in terms of the natural length and energy scales of the problem. The existence of such condensed phases, which are of obvious significance in the context of elementary particles, have also been scrutinized.
Er. Shivesh Kumar; Dr. Amit Kumar
2016-01-01
Since centuries steam is being used in power generating system. The steam leaving the power unit is reconverted into water in a condenser designed to transfer heat from the steam to the cooling water as rapidly and as efficiently as possible. The efficiency of condenser depends on rate of condensation and mode of condensation of steam in the condenser. The increase in efficiency of the condenser enhances the heat transfer co-efficient which in turn results in economic design of condenser and ...
Bio-oil fractionation and condensation
Brown, Robert C; Jones, Samuel T; Pollard, Anthony
2013-07-02
A method of fractionating bio-oil vapors which involves providing bio-oil vapors comprising bio-oil constituents is described. The bio-oil vapors are cooled in a first stage which comprises a condenser having passages for the bio-oil separated by a heat conducting wall from passages for a coolant. The coolant in the condenser of the first stage is maintained at a substantially constant temperature, set at a temperature in the range of 75 to 100.degree. C., to condense a first liquid fraction of liquefied bio-oil constituents in the condenser of the first stage. The first liquid fraction of liquified bio-oil constituents from the condenser in the first stage is collected. Also described are steps for subsequently recovering further liquid fractions of liquefied bio-oil constituents. Particular compositions of bio-oil condensation products are also described.
Energy Technology Data Exchange (ETDEWEB)
Metin Ertunc, H. [Department of Mechatronics Engineering, Kocaeli University, Umuttepe, 41380 Kocaeli (Turkey); Hosoz, Murat [Department of Mechanical Education, Kocaeli University, Umuttepe, 41380 Kocaeli (Turkey)
2008-12-15
This study deals with predicting the performance of an evaporative condenser using both artificial neural network (ANN) and adaptive neuro-fuzzy inference system (ANFIS) techniques. For this aim, an experimental evaporative condenser consisting of a copper tube condensing coil along with air and water circuit elements was developed and equipped with instruments used for temperature, pressure and flow rate measurements. After the condenser was connected to an R134a vapour-compression refrigeration circuit, it was operated at steady state conditions, while varying both dry and wet bulb temperatures of the air stream entering the condenser, air and water flow rates as well as pressure, temperature and flow rate of the entering refrigerant. Using some of the experimental data for training, ANN and ANFIS models for the evaporative condenser were developed. These models were used for predicting the condenser heat rejection rate, refrigerant temperature leaving the condenser along with dry and wet bulb temperatures of the leaving air stream. Although it was observed that both ANN and ANFIS models yielded a good statistical prediction performance in terms of correlation coefficient, mean relative error, root mean square error and absolute fraction of variance, the accuracies of ANFIS predictions were usually slightly better than those of ANN predictions. This study reveals that, having an extended prediction capability compared to ANN, the ANFIS technique can also be used for predicting the performance of evaporative condensers. (author)
Chromosome condensation and segmentation
International Nuclear Information System (INIS)
Viegas-Pequignot, E.M.
1981-01-01
Some aspects of chromosome condensation in mammalians -humans especially- were studied by means of cytogenetic techniques of chromosome banding. Two further approaches were adopted: a study of normal condensation as early as prophase, and an analysis of chromosome segmentation induced by physical (temperature and γ-rays) or chemical agents (base analogues, antibiotics, ...) in order to show out the factors liable to affect condensation. Here 'segmentation' means an abnormal chromosome condensation appearing systematically and being reproducible. The study of normal condensation was made possible by the development of a technique based on cell synchronization by thymidine and giving prophasic and prometaphasic cells. Besides, the possibility of inducing R-banding segmentations on these cells by BrdU (5-bromodeoxyuridine) allowed a much finer analysis of karyotypes. Another technique was developed using 5-ACR (5-azacytidine), it allowed to induce a segmentation similar to the one obtained using BrdU and identify heterochromatic areas rich in G-C bases pairs [fr
Characteristic aspects of pion-condensed phases
International Nuclear Information System (INIS)
Takatsuka, Tatsuyuki; Tamagaki, Ryozo; Tatsumi, Toshitaka.
1993-01-01
Characteristic aspects of pion-condensed phases are described in a simple model, for the system involving only nucleons and pions which interact through the π-N P-wave interaction. We consider one typical version in each of three kinds of pion condensation; the one of neutral pions (π 0 ), the one of charged pions (π C ) and the combined one in which both the π 0 and π C condensations are coexistent. Emphasis is put on the description to clarify the novel structures of the nucleon system which are realized in the pion-condensed phases. At first, it is shown that the π 0 condensation is equivalent to the particular nucleonic phase realized by a structure change of the nucleon system, where the attractive first-order effect of the one-pion-exchange (OPE) tensor force is brought about coherently. The aspects of this phase are characterized by the layered structure with a specific spin-isospin order with one-dimensional localization (named the ALS structure in short), which provides the source function for the condensed π 0 field. We utilize both descriptions with use of fields and potentials for the π 0 condensation. Next, the π C condensation realized in neutron-rich matter is described by adopting a version of the traveling condensed wave. In this phase, the nucleonic structure becomes the Fermi gas consisting of quasi-neutrons described by a superposition of neutron and proton. In this sense the structure change of the nucleon system for the π C condensation is moderate, and the field description is suitable. Finally, we describe a coexistent pion condensation, in which both the π 0 and π C condensations coexist without interference in such a manner that the π C condensation develops in the ALS structure. The model adopted here provides us with the characteristic aspects of the pion-condensed phases persisting in the realistic situation, where other ingredients affecting the pion condensation are taken into account. (author)
DEFF Research Database (Denmark)
Malterud, Kirsti
2012-01-01
To present background, principles, and procedures for a strategy for qualitative analysis called systematic text condensation and discuss this approach compared with related strategies.......To present background, principles, and procedures for a strategy for qualitative analysis called systematic text condensation and discuss this approach compared with related strategies....
Measures against the adverse impact of natural wind on air-cooled condensers in power plant
Institute of Scientific and Technical Information of China (English)
无
2010-01-01
The natural wind plays disadvantageous roles in the operation of air-cooled steam condensers in power plant.It is of use to take various measures against the adverse effect of wind for the performance improvement of air-cooled condensers.Based on representative 2×600 MW direct air-cooled power plant,three ways that can arrange and optimize the flow field of cooling air thus enhance the heat transfer of air-cooled condensers were proposed.The physical and mathematical models of air-cooled condensers with various flow leading measures were presented and the flow and temperature fields of cooling air were obtained by CFD simulation.The back pressures of turbine were calculated for different measures on the basis of the heat transfer model of air-cooled condensers.The results show that the performance of air-cooled condensers is improved thus the back pressure of turbine is lowered to some extent by taking measures against the adverse impact of natural wind.
Energy Technology Data Exchange (ETDEWEB)
Papini, Davide, E-mail: davide.papini@psi.ch; Adamsson, Carl; Andreani, Michele; Prasser, Horst-Michael
2014-10-15
Highlights: • Code comparison on the performance of a Passive Containment Condenser. • Simulation of separate effect tests with pure steam and non-condensable gases. • Role of the secondary side and accuracy of pool boiling models are discussed. • GOTHIC and TRACE predict the experimental performance with slight underestimation. • Recirculatory flow pattern with injection of light non-condensable gas is inferred. - Abstract: Typical passive safety systems for ALWRs (Advanced Light Water Reactors) rely on the condensation of steam to remove the decay heat from the core or the containment. In the present paper the three-dimensional containment code GOTHIC and the one-dimensional system code TRACE are compared on the calculation of a variety of phenomena characterizing the response of a passive condenser submerged in a boiling pool. The investigation addresses the conditions of interest for the Passive Containment Cooling System (PCCS) proposed for the ESBWR (Economic Simplified Boiling Water Reactor). The analysis of selected separate effect tests carried out on a PCC (Passive Containment Condenser) unit in the PANDA large-scale thermal-hydraulic facility is presented to assess the code predictions. Both pure steam conditions (operating pressure of 3 bar, 6 bar and 9 bar) and the effect on the condensation heat transfer of non-condensable gases heavier than steam (air) and lighter than steam (helium) are considered. The role of the secondary side (pool side) heat transfer on the condenser performance is examined too. In general, this study shows that both the GOTHIC and TRACE codes are able to reasonably predict the heat transfer capability of the PCC as well as the influence of non-condensable gas on the system. A slight underestimation of the condenser performance is obtained with both codes. For those tests where the experimental and simulated efficiencies agree better the possibility of compensating errors among different parts of the heat transfer
On nitrogen condensation in hypersonic nozzle flows: Numerical method and parametric study
Lin, Longyuan
2013-12-17
A numerical method for calculating two-dimensional planar and axisymmetric hypersonic nozzle flows with nitrogen condensation is developed. The classical nucleation theory with an empirical correction function and the modified Gyarmathy model are used to describe the nucleation rate and the droplet growth, respectively. The conservation of the liquid phase is described by a finite number of moments of the size distribution function. The moment equations are then combined with the Euler equations and are solved by the finite-volume method. The numerical method is first validated by comparing its prediction with experimental results from the literature. The effects of nitrogen condensation on hypersonic nozzle flows are then numerically examined. The parameters at the nozzle exit under the conditions of condensation and no-condensation are evaluated. For the condensation case, the static pressure, the static temperature, and the amount of condensed fluid at the nozzle exit decrease with the increase of the total temperature. Compared with the no-condensation case, both the static pressure and temperature at the nozzle exit increase, and the Mach number decreases due to the nitrogen condensation. It is also indicated that preheating the nitrogen gas is necessary to avoid the nitrogen condensation even for a hypersonic nozzle with a Mach number of 5 operating at room temperatures. © 2013 Springer-Verlag Berlin Heidelberg.
International Nuclear Information System (INIS)
Najmy, S.W.
2002-01-01
Condensate polishing is an application with many different design and operational aspects. The past decade has brought new challenges for improved water quality with respect to both soluble and insoluble contaminants. Nonetheless, the endeavors to understand the compositional complexities of the ion exchange resin bead and the convoluted dynamics of ion exchange chemistry and chemical engineering mechanisms occurring within the mixed bed condensate polisher have brought new ideas and expectations for ion exchange resin in deep-bed condensate polishers than ever before. The new products and procedures presented here are a collaboration of a great deal of effort on the part of researchers, consultants, system engineers, station chemists, lab technicians and others. The studies discussed in this paper unequivocally demonstrate the merits of: 1. A specially designed cation resin to achieve greater than 95% insoluble iron removal efficiency, 2. A less-separable mixed resin for improved control of reactor water sulfate in BWR primary cycles, 3. Applying increased levels of regeneration chemicals and retrofitting the service vessels with re-mixing capability to improve the operation of deep-bed condensate polishers in PWR secondary cycles. (authors)
Signal characteristics of guided wave for condenser tube of NPP
International Nuclear Information System (INIS)
Min, Lee Dong; Hoon, Choi Sang; Yeong, Yang Tae
2012-01-01
A Condenser is a large heat exchanger of the shell and tube type. Cooling water enters through the water box, through the tubesheet and into the tubes(about 80,000 tubes/unit). The shell side of the condenser receives steam from the low pressure turbines exhaust. The steam is cooled to a liquid by passing over the tubes where the cooling water is circulated. Because seawater is used as a coolant, condenser tubes are easily damaged. For such a reason, nondestructive testing conducted periodically. But nondestructive testing takes a lot of manpower and time. Guided wave technique can overcome these shortcomings. In this study, we made an effort evaluating a guided wave defect signal
On the performance of air conditioner with heat pipe for cooling air in the condenser
Energy Technology Data Exchange (ETDEWEB)
Naphon, Paisarn, E-mail: paisarnn@swu.ac.t [Thermo-Fluids and Heat Transfer Enhancement Laboratory (TFHT), Department of Mechanical Engineering, Faculty of Engineering, Srinakharinwirot University, 63 Rangsit-Nakhornnayok Rd., Ongkharak, Nakhorn-Nayok 26120 (Thailand)
2010-11-15
Improvement of the air conditioning system performance by using the heat pipe for cooling air before entering the condenser is presented. In the experiment, the heat pipe is fabricated from the straight copper tube with the diameter and length of 10, 600 mm, respectively. The arrangements of the heat pipe sets are arranged in the staggered layout with the tube rows of 1, 2, 3. R134a refrigerant is used as working fluid in the heat pipe set for this present study. By comparing with a conventional air conditioning system, the air conditioning system with three rows of heat pipe gives the highest COP and EER with increasing of 6.4%, 17.5%, respectively. On the global warming and environment problems, the results of this study are expected to lead to guidelines that will allow the improved performance of the air conditioning systems which reduce its energy consumption.
On the performance of air conditioner with heat pipe for cooling air in the condenser
International Nuclear Information System (INIS)
Naphon, Paisarn
2010-01-01
Improvement of the air conditioning system performance by using the heat pipe for cooling air before entering the condenser is presented. In the experiment, the heat pipe is fabricated from the straight copper tube with the diameter and length of 10, 600 mm, respectively. The arrangements of the heat pipe sets are arranged in the staggered layout with the tube rows of 1, 2, 3. R134a refrigerant is used as working fluid in the heat pipe set for this present study. By comparing with a conventional air conditioning system, the air conditioning system with three rows of heat pipe gives the highest COP and EER with increasing of 6.4%, 17.5%, respectively. On the global warming and environment problems, the results of this study are expected to lead to guidelines that will allow the improved performance of the air conditioning systems which reduce its energy consumption.
Condensed tannins act against cattle nematodes
DEFF Research Database (Denmark)
Novobilský, Adam; Mueller-Harvey, Irene; Thamsborg, Stig Milan
2011-01-01
The use of natural plant anthelmintics was suggested as a possible alternative control of gastrointestinal nematodes (GIN) in ruminants. Direct anthelmintic effects of tannin-containing plants have already been shown in sheep and goat GIN. These anthelmintic properties are mainly associated...... with condensed tannins. In the present study, we evaluated possible in vitro effects of three tannin-containing plants against bovine GIN. Effects of Onobrychis viciifolia, Lotus pedunculatus and Lotus corniculatus condensed tannin (CT) extracts on Cooperia oncophora and Ostertagia ostertagi were determined...... (third stage larvae) was also affected by CT extracts from all three plants. In both in vitro assays, extracts with added polyvinylpolypyrrolidone, an inhibitor of tannins, generated almost the same values as the negative control; this confirms the role of CT in the anthelmintic effect of these plant...
Energy Technology Data Exchange (ETDEWEB)
Ju, Yun Jae; Lee, Hee Joon [Kookmin Univ., Seoul (Korea, Republic of); Kang, Hanok; Lee, Taeho; Park, Cheontae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
2013-12-15
Recently, condensation heat exchangers have been studied for applications to the passive cooling systems of nuclear plants. To design vertical-type condensation heat exchangers in secondary passive cooling systems, TSCON (Thermal Sizing of CONdenser), a thermal sizing program for a condensation heat exchanger, was developed at KAERI (Korea Atomic Energy Research Institute). In this study, the existing condensation heat transfer correlation of TSCON was evaluated using 1,157 collected experimental data points from the heat exchanger of a secondary passive cooling system for the case of pure steam condensation. The investigation showed that the Shah correlation, published in 2009, provided the most satisfactory results for the heat transfer coefficient with a mean absolute error of 34.8%. It is suggested that the Shah correlation is appropriate for designing a condensation heat exchanger in TSCON.
Reflux condensation behavior in SBLOCA tests of ATLAS facility
International Nuclear Information System (INIS)
Kim, Yeon-Sik; Park, Hyun-Sik; Cho, Seok; Choi, Ki-Yong; Kang, Kyoung-Ho
2017-01-01
Highlights: • Behavior of a reflux condensation heat transfer was investigated for SBLOCA tests. • Behavior of the reflux condensate in HL, SG inlet plenum, and U-tubes were evaluated. • Concept of a steam moisturizing phenomenon was introduced and discussed. • Test data and MARS calculations were compared and discussed on the reflux condensate. - Abstract: The behavior of the reflux condensation heat transfer in a hot side steam generator (SG) U-tubes during a cold leg (CL) pipe and a direct vessel injection (DVI) line break in small break loss-of-coolant accident (SBLOCA) tests of the ATLAS facility was investigated including MARS code calculations. Among the SBLOCA tests, a 6″-CL pipe and 50%-DVI line break SBLOCA test were selected to investigate the behavior of the reflux condensation. A reflux condensation heat transfer seemed to occur from the time the SG U-tubes were half-empty to near the loop seal clearing (LSC). It was found that a transition regime existed between the reflux condensation heat transfer and reverse heat transfer. The remaining reflux condensate in SG U-tubes owing to the counter-current flow limit (CCFL) phenomenon and a separating effect of liquid carry-over and/or entrainment with steam moisturizing seemed to affect the thermal-hydraulic behavior of the transition regime. It was also found that the steam flowrate of the loop pipings and SG U-tubes seemed to have a strong effect on the duration time of the transition regime, e.g., a larger steam flowrate results in a longer duration. From a comparison of the reflux condensation behavior between the ATLAS tests and MARS code calculations, overall qualitative agreements were found between the two cases. The largest discrepancies were found in the SG inlet plenum water level between the two cases, and the authors suggest that the combination effects of the remaining reflux condensate in SG U-tubes and a separating effect of liquid carry-over and/or entrainment with steam
Energy Technology Data Exchange (ETDEWEB)
Jeon, Seong-Su [Department of Engineering Project, FNC Technology Co., Ltd., Bldg. 135-308, Seoul National University, Gwanak-gu, Seoul 151-744 (Korea, Republic of); Department of Nuclear Engineering, Seoul National University, Gwanak-gu, Seoul 151-744 (Korea, Republic of); Hong, Soon-Joon, E-mail: sjhong90@fnctech.com [Department of Engineering Project, FNC Technology Co., Ltd., Bldg. 135-308, Seoul National University, Gwanak-gu, Seoul 151-744 (Korea, Republic of); Park, Ju-Yeop; Seul, Kwang-Won [Korea Institute of Nuclear Safety, 19 Kuseong-dong, Yuseong-gu, Daejon (Korea, Republic of); Park, Goon-Cherl [Department of Nuclear Engineering, Seoul National University, Gwanak-gu, Seoul 151-744 (Korea, Republic of)
2013-01-15
Highlights: Black-Right-Pointing-Pointer This study collected 11 horizontal in-tube condensation models for stratified flow. Black-Right-Pointing-Pointer This study assessed the predictive capability of the models for steam condensation. Black-Right-Pointing-Pointer Purdue-PCCS experiments were simulated using MARS code incorporated with models. Black-Right-Pointing-Pointer Cavallini et al. (2006) model predicts well the data for stratified flow condition. Black-Right-Pointing-Pointer Results of this study can be used to improve condensation model in RELAP5 or MARS. - Abstract: The accurate prediction of the horizontal in-tube condensation heat transfer is a primary concern in the optimum design and safety analysis of horizontal heat exchangers of passive safety systems such as the passive containment cooling system (PCCS), the emergency condenser system (ECS) and the passive auxiliary feed-water system (PAFS). It is essential to analyze and assess the predictive capability of the previous horizontal in-tube condensation models for each flow regime using various experimental data. This study assessed totally 11 condensation models for the stratified flow, one of the main flow regime encountered in the horizontal condenser, with the heat transfer data from the Purdue-PCCS experiment using the multi-dimensional analysis of reactor safety (MARS) code. From the assessments, it was found that the models by Akers and Rosson, Chato, Tandon et al., Sweeney and Chato, and Cavallini et al. (2002) under-predicted the data in the main condensation heat transfer region, on the contrary to this, the models by Rosson and Meyers, Jaster and Kosky, Fujii, Dobson and Chato, and Thome et al. similarly- or over-predicted the data, and especially, Cavallini et al. (2006) model shows good predictive capability for all test conditions. The results of this study can be used importantly to improve the condensation models in thermal hydraulic code, such as RELAP5 or MARS code.
Energy Technology Data Exchange (ETDEWEB)
Kawamura, T; Ito, S; Miura, N [Kanagawa Institute of Technology, Kanagawa (Japan); Fujita, M [Chubu Electric Power Co. Inc., Nagoya (Japan)
1996-10-27
Comparison was made between heat pumps in cooling operation, one having two panels provided with solar cells, the second having an air-cooled heat exchanger alone, and the third having a series connection of a panel unit and air-cooled heat exchanger, all serving as condenser. The results are shown below. In the case of two-panel-unit condenser, there is a difference ({Delta}t) of 15{degree}C between the daytime free air temperature and condensing temperature but, with decreased insolation, free air temperature, and wind speed in the evening, the {Delta}t lowered to approximately 8{degree}C while the COP (coefficient of performance) increased from 2.4 to 3.3. On a cloudy day in summer, the two-panel-unit condenser had a {Delta}t of 13.9{degree}C and a COP of 3.1. In the case of the series-connection condenser, the {Delta}t was approximately 8{degree}C and the COP was 3.5. The COP of the two-panel-unit condenser was lower than that of the air-cooled heat exchanger by 9% at an insolation of 442W/m{sup 2} but it rose to 12% in the absence of insolation. The COP of the two-panel-unit condenser was higher than that of a one-panel-unit condenser by 17%. When an insulator plate was attached to the back of a panel, the {Delta}t increased but the COP decreased by 14%. In the case of the series-connection condenser, the COP increased by 6% in the absence of the insulator plate. 2 refs., 9 figs.
Donati, Ivan; Benegas, Julio C; Cesàro, Attilio; Paoletti, Sergio
2006-05-01
in the specific binding sites, sigma0, was evaluated. In particular, a remarkable decrease in the amount of condensed counterions has been pointed out in the case of sigma0 = 1/3, with respect to the value of sigma0 = 1/4, characterizing the traditional "egg-box" structure, as a result of the drop of the charge density of the polyelectrolyte induced by complete charge annihilation.
Lesson learned from the SARNET wall condensation benchmarks
International Nuclear Information System (INIS)
Ambrosini, W.; Forgione, N.; Merli, F.; Oriolo, F.; Paci, S.; Kljenak, I.; Kostka, P.; Vyskocil, L.; Travis, J.R.; Lehmkuhl, J.; Kelm, S.; Chin, Y.-S.; Bucci, M.
2014-01-01
Highlights: • The results of the benchmarking activity on wall condensation are reported. • The work was performed in the frame of SARNET. • General modelling techniques for condensation are discussed. • Results of University of Pisa and of other benchmark participants are discussed. • The lesson learned is drawn. - Abstract: The prediction of condensation in the presence of noncondensable gases has received continuing attention in the frame of the Severe Accident Research Network of Excellence, both in the first (2004–2008) and in the second (2009–2013) EC integrated projects. Among the different reasons for considering so relevant this basic phenomenon, coped with by classical treatments dated in the first decades of the last century, there is the interest for developing updated CFD models for reactor containment analysis, requiring validating at a different level the available modelling techniques. In the frame of SARNET, benchmarking activities were undertaken taking advantage of the work performed at different institutions in setting up and developing models for steam condensation in conditions of interest for nuclear reactor containment. Four steps were performed in the activity, involving: (1) an idealized problem freely inspired at the actual conditions occurring in an experimental facility, CONAN, installed at the University of Pisa; (2) a first comparison with experimental data purposely collected by the CONAN facility; (3) a second comparison with data available from experimental campaigns performed in the same apparatus before the inclusion of the activities in SARNET; (4) a third exercise involving data obtained at lower mixture velocity than in previous campaigns, aimed at providing conditions closer to those addressed in reactor containment analyses. The last step of the benchmarking activity required to change the configuration of the experimental apparatus to achieve the lower flow rates involved in the new test specifications. The
Condensation heat transfer on natural convection at the high pressure
International Nuclear Information System (INIS)
Jong-Won, Kim; Hyoung-Kyoun, Ahn; Goon-Cherl, Park
2007-01-01
The Regional Energy Research Institute for the Next Generation is to develop a small scale electric power system driven by an environment-friendly and stable small nuclear reactor. REX-10 has been developed to assure high system safety in order to be placed in densely populated region and island. REX-10 adopts the steam-gas pressurizer to assure the inherent safety. The thermal-hydraulic phenomena in the steam-gas pressurizer are very complex. Especially, the condensation heat transfer with noncondensable gas on the natural convection is important to evaluate the pressurizer behavior. However, there have been few investigations on the condensation in the presence of noncondensable gas at the high pressure. In this study, the theoretical model is developed to estimate the condensation heat transfer at the high pressure using heat and mass transfer analogy. The analysis results show good agreement with correlations and experimental data. It is found that the condensation heat transfer coefficient increases as the total pressure increases or the mass fraction of the non-condensable gas decreases. In addition, the heat transfer coefficient no more increases over the specific pressure
Design of condenser for 500 MWe pressurised heavy water reactors (PHWRs) - a case study
International Nuclear Information System (INIS)
Agarwal, N.K.; Subbarao, A.; Chaudhary, K.
1996-01-01
Condenser forms the major heat sink in the power plants. In recent years, power plant availability and performance have become great concern to the industry. The detailed design of the condenser and its associated cooling water (CW) system require careful optimisation of parameters which include material selection, cooling water flow rate, condenser surface areas, turbine exhaust pressures etc. This is required to produce a design offering maximum efficiency and reliability and minimum maintenance. The various parameters involved in condenser design are discussed. 5 refs., 1 fig
Humidification Dehumidification Spray Column Direct Contact Condenser Part I: Countercurrent Flow
International Nuclear Information System (INIS)
Shouman, L.; Karameldin, A.; Fadel, D.
2015-01-01
Humidification-dehumidification (HDH) is a low grade energy desalination technology. The waste heat from power plant (such NPP) can be used as heat source to preheat water (in evaporator) and air (in condenser) . Hot humid air and cooled spray water in counter current flow with direct contact is theoretically analyzing in the present work. Direct contact spray condenser is studied to provide the effect of various parameters on its performance. A computer programme describing the theoretical model is designed to solve a one-dimensional differential equations by using Rung–Kutta method. The programme predicts the droplet radius, velocity and temperature, besides, the humidity and temperature of air. The results show that, the length of column has great effect on the performance of spray condenser. At column height of 0.762, 2, 5, 10, and 20 m the humidity of the output air decreases by 50%, 72%, 89%, 97%, and 99% respectively. The condensate increases about 35% when the length increase from 5 to 10 m at ΔT = 25°C while increase only 18% at ΔT = 30°C. Also, it is found that, at ΔT = 25°C the condensate decrease from H = 10 to 5 m about 31% and increases from 10 to 20 m about 32%. While these results for ΔT = 25°C are 32% from H = 10 to 5 m and 36% from 10 to 20 m.The increase of both water and air mass fluxes increases the condensate mass flow rate. (author)
Energy Technology Data Exchange (ETDEWEB)
Raindl, Markus
2010-12-06
Condensation of a steam-inert gas mixture in an Oxyfuel condenser differs significantly from condensation of pure steam: condenser pressure and rest gas content increase dramatically, heat- and mass transfer coefficients are lower and oversaturation of the steam-inert gas mixture yields to fog formation. In the context of this thesis, therefore, at first the optimal ranges of working parameters for Oxyfuel processes calculated. In the following some heat flux measurements were carried out on a horizontal, crossflow pipe to validate various heat- and mass transfer theories. Building on these results a new, efficient condensation concept was developed to reduce fog formation. The final results of the measurements with a laboratory model show great performance regarding fog reduction and condensation efficiency. (orig.)
Hindle, Michael; Longest, P. Worth
2010-01-01
Purpose The objective of this study is to evaluate the effects of enhanced condensational growth (ECG), as a novel inhalation drug delivery method, on nano-aerosol deposition in a mouth-throat (MT) and upper tracheobronchial (TB) model using in vitro experiments and computational fluid dynamics (CFD) simulations. Methods Separate streams of nebulized nano-aerosols and saturated humidified air (39°C—ECG; 25°C—control) were combined as they were introduced into a realistic MT-TB geometry. Aerosol deposition was determined in the MT, generations G0–G2 (trachea—lobar bronchi) and G3–G5 and compared to CFD simulations. Results Using ECG conditions, deposition of 560 and 900 nm aerosols was low in the MT region of the MT-TB model. Aerosol drug deposition in the G0–G2 and G3–G5 regions increased due to enhanced condensational growth compared to control. CFD-predicted depositions were generally in good agreement with the experimental values. Conclusions The ECG platform appears to offer an effective method of delivering nano-aerosols through the extrathoracic region, with minimal deposition, to the tracheobronchial airways and beyond. Aerosol deposition is then facilitated as enhanced condensational growth increases particle size. Future studies will investigate the effects of physio-chemical drug properties and realistic inhalation profiles on ECG growth characteristics. PMID:20454837
Condensate from a two-stage gasifier
DEFF Research Database (Denmark)
Bentzen, Jens Dall; Henriksen, Ulrik Birk; Hindsgaul, Claus
2000-01-01
Condensate, produced when gas from downdraft biomass gasifier is cooled, contains organic compounds that inhibit nitrifiers. Treatment with activated carbon removes most of the organics and makes the condensate far less inhibitory. The condensate from an optimised two-stage gasifier is so clean...... that the organic compounds and the inhibition effect are very low even before treatment with activated carbon. The moderate inhibition effect relates to a high content of ammonia in the condensate. The nitrifiers become tolerant to the condensate after a few weeks of exposure. The level of organic compounds...... and the level of inhibition are so low that condensate from the optimised two-stage gasifier can be led to the public sewer....
Characteristics of flow in turbine-condenser connections
International Nuclear Information System (INIS)
Yasugahira, Norio; Sato, Takeshi; Mukai, Yasuteru; Otake, Katsumoto; Miyai, Masahiko
1981-01-01
It is important to save energy in thermal and nuclear power plants, and Hitachi Ltd. has exerted efforts on this subject. The performance of condensers depends largely on the condition of steam flow into the tube nests, and is affected by the state of steam flow in the connecting parts between LP turbines and the condensers. It is desirable to give turbines low exhaust pressure by minimizing the resistance of the obstacles in the diffuser paths and increasing the restoration of static pressure. But in the connecting parts, feed water heaters, bleeding pipes and stiffeners are placed, and if these re arranged inadequately, the performance of condensers and the efficiency of turbines are lowered by pressure loss. In this study, the flow in the connecting parts was reproduced with models, and the detailed state of internal flow was grasped. Also the influence of the form of the connecting parts, feed water heaters and bleeding pipes on pressure loss was examined, and the measures to reduce the pressure loss were sought. The cases of the connecting parts containing one feed water heater and four feed water heaters were examined. The experimental setup, the structure of the tested models, and the test results are reported. The velocity distribution and flow pattern of the internal flow were obtained, and the arrangement of feed water heaters which reduces pressure loss was clarified. (Kako, I.)
International Nuclear Information System (INIS)
Zhou, W.; Wolf, B.; Revankar, S.T.
2011-01-01
The passive containment condenser system (PCCS) in an ESBWR reactor consists of vertical tube bundle submerged in a large pool of water. The condensation model for the PCCS in a thermalhydraulics code RELAP5/MOD3.3 consists of the default Nusselt model and an alternate condensation model from UCB condensation correlation. An assessment of the PCCS condensation model in RELAP5/MOD3.3 was carried out using experiments conducted on a single tube and tube bundle PCCS tests at Purdue University. The experimental conditions were simulated with the default and the alternate condensation models in the REALP5/MOD3.3 beta version of the code. The default model and the UCB model (alternate model) give quite different results on condensation heat transfer for the PCCS. The default model predicts complete condensation well whereas the UCB model predicts the through flow condensation well. Based on this study it was found that none of the models in REALP5 can predict complete condensation as well as the through flow condensation well. (author)
Energy Technology Data Exchange (ETDEWEB)
Zhou, W., E-mail: wenzzhou@cityu.edu.hk [Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong (China); Wolf, B. [Purdue University, West Lafayette, IN 47907 (United States); Revankar, S. [Purdue University, West Lafayette, IN 47907 (United States); POSTECH, Pohang (Korea, Republic of)
2013-11-15
The passive containment condenser system (PCCS) in an ESBWR reactor consists of vertical tube bundle submerged in a large pool of water. The condensation model for the PCCS in a thermalhydraulics code RELAP5/MOD3.3 consists of the default Nusselt model and an alternate condensation model from UCB condensation correlation. An assessment of the PCCS condensation model in RELAP5/MOD3.3 was carried out using experiments conducted on a single tube and tube bundle PCCS tests at Purdue University. The experimental conditions were simulated with the default and the alternate condensation models in the REALP5/MOD3.3 beta version of the code. The default model and the UCB model (alternate model) give quite different results on condensation heat transfer for the PCCS. The default model predicts complete condensation well whereas the UCB model predicts the through flow condensation well. Based on this study it was found that none of the models in REALP5 can predict complete condensation as well as the through flow condensation well.
The Effect of Capillary Number on a Condensate Blockage in Gas Condensate Reservoirs
Saifon DAUNGKAEW; Alain C GRINGARTEN
2004-01-01
In the petroleum industry, gas condensate reservoirs are becoming more common as exploration targets. However, there is a lack of knowledge of the reservoir behaviour mainly due to its complexity in the near wellbore region, where two phases, i.e. reservoir gas and condensate coexist when the wellbore pressure drops below the dew point pressure. The condensation process causes a reduction of the gas productivity (1). It has been reported in the literature that there is an increasing gas mobil...
An Experimental Study of the Dropwise Condensation on Physically Processed Surface
International Nuclear Information System (INIS)
Choi, Jaeyoung; Chang, Soonheung; Watanabe, N.; Sambuichi, T.; Shiota, D.; Aritomi, M.
2013-01-01
Recent research by Kawakubo et al. derived empirical condensation heat transfer correlation suitable for wider range of operating condition in presence of non-condensable gas. However, their proposals of PCCS are focused on plane tube surface. To design better PCCS heat exchanger with high heat transfer coefficient new treatment on condensation surface can be considered in order to maintain dropwise condensation, the heat transfer coefficient of which has an order of magnitude larger than those of film condensation. Advanced research measure dropwise condensation heat transfer coefficient of Au and Cr coated surface based on number of droplet and droplet growth rate. However, coated surface is not desirable in power plant due to its duration of few years. On the other hand, physical processing (micro holes and patterns) on stainless steel and titanium surface is expected to perform better heat transfer, also is durable for the whole reactor lifetime. Since there is no published research about dropwise condensation for physically processed surface on SUS and Ti, the purposes of this research are to measure the condensation heat transfer coefficient and analyze its mechanism of enhanced heat transfer of treated SUS and Ti commonly used to nuclear plant. In the comparison of theoretical equation and experiment, it shows same result that heat transfer coefficient is proportional to maximum droplet diameter power to -0.321. Moreover, in the comparison of bare and processed surface, heat transfer coefficient decreases in processed surface
Condensation heat transfer in plate heat exchangers
International Nuclear Information System (INIS)
Panchal, C.B.
1985-01-01
An Alfa-Laval plate heat exchanger, previously tested as an evaporator, was retested as a condenser. Two series of tests with different chevron-angle plates were carried out using ammonia as a working fluid. The overall heat-transfer coefficient and pressure drop were measured, and the effects of operating parameters were determined. The experimental data were compared with theoretical predictions. In the analysis, a gravity-controlled condensation process was modeled theoretically, and the overall performance was calculated. The analysis shows that the overall heat-transfer coefficient can be predicted with an average uncertainty of about 10%. It is, however, important to consider the interfacial shear stress, because the effective friction factor is high for flow in plate heat exchangers
Ghost condensate and generalized second law
International Nuclear Information System (INIS)
Mukohyama, Shinji
2009-01-01
Dubovsky and Sibiryakov recently proposed a scenario in which particles of different species propagate with different speeds due to their direct couplings to ghost condensate. It was argued that this extended version of ghost condensate allows a gedanken experiment leading to violation of the generalized second law. However, in the original ghost condensate scenario, difference in propagation speeds is suppressed by M 2 /M Pl 2 , where M is the order parameter of spontaneous Lorentz breaking and M Pl is the Planck scale. In this case the energy transfer necessary for the gedanken experiment is so slow that the timescale of decrease of entropy, if any, is always longer than the Jeans timescale of ghost condensate. Hence the generalized second law is not violated by the gedanken experiment in the original ghost condensate scenario. This conclusion trivially extends to gauged ghost condensation by taking into account accretion of gauged ghost condensate into a black hole.
Black holes in the ghost condensate
International Nuclear Information System (INIS)
Mukohyama, Shinji
2005-01-01
We investigate how the ghost condensate reacts to black holes immersed in it. A ghost condensate defines a hypersurface-orthogonal congruence of timelike curves, each of which has the tangent vector u μ =-g μν ∂ ν φ. It is argued that the ghost condensate in this picture approximately corresponds to a congruence of geodesics. In other words, the ghost condensate accretes into a black hole just like a pressureless dust. Correspondingly, if the energy density of the ghost condensate at large distance is set to an extremely small value by cosmic expansion then the late-time accretion rate of the ghost condensate should be negligible. The accretion rate remains very small even if effects of higher derivative terms are taken into account, provided that the black hole is sufficiently large. It is also discussed how to reconcile the black-hole accretion with the possibility that the ghost condensate might behave like dark matter
Energy Technology Data Exchange (ETDEWEB)
Louahlia, H.; Panday, P.K. [Institut de Genie Energetique, 90 - Belfort (France)
1997-12-31
This paper presents a comparison between turbulence models based on Prandtl theory and applied to the problem of pure fluids condensation. A theoretical model is defined which allows to determine the physical characteristics of condensation between two vertical or horizontal flat plates. The total heat flux exchanged at the wall and the mean Nusselt number are calculated using several closure models in the liquid and vapor phases. Calculation results obtained for the R123 condensation between two vertical plates show that the Pletcher`s model or the Groenwald and Kroeger`s one applied to the vapor flow and the Von Karman`s model used for the liquid film predict thermal fluxes close to the measured ones. It has been noticed also that the condensation heat transfer is underestimated in the laminar model. In the case of the R113 condensation on an horizontal flat plate, the mean Nusselt numbers estimated in the Pletcher`s model applied to both phases are close to the measurements performed by Lu and Suryanarayana. (J.S.) 12 refs.
Misra, Prasanta K
2012-01-01
Physics of Condensed Matter is designed for a two-semester graduate course on condensed matter physics for students in physics and materials science. While the book offers fundamental ideas and topic areas of condensed matter physics, it also includes many recent topics of interest on which graduate students may choose to do further research. The text can also be used as a one-semester course for advanced undergraduate majors in physics, materials science, solid state chemistry, and electrical engineering, because it offers a breadth of topics applicable to these majors. The book be
Energy Technology Data Exchange (ETDEWEB)
De Cachard, F.; Lompersky, S.; Monauni, G.R. [Paul Scherrer Institute, Villigen (Switzerland). Thermal Hydraulic Lab.
1999-07-01
An experimental and analytical program was performed at PSI (Paul Scherrer Institute) to study the performance of a finned-tube condenser in the presence of non-condensable gases at low gas mass fluxes. The model developed for this application includes mixed convection heat transfer between the vapour/non-condensable mixture and the finned tubes, heat conduction through the fins and tubes, and evaporative heat transfer inside the tubes. On the gas, heat transfer correlations are used, and the condensation rate is calculated using the heat/mass transfer analogy. A combination of various available correlations for forced convection in staggered finned tube bundles is used, together with a correction accounting for superimposed natural convection. For the condensate heat transfer resistance, the beatty and Katz model for gravity driven liquid films on the tubes is used. The fine efficiency is accounted for using classical iterative calculations. Evaporative heat transfer inside the tubes is predicted using the Chen correlation. The finned tube condenser model has been assessed against data obtained at the PSI LINX facility with two test condensers. For the 62 LINX experiments performed, the model predictions are very good, i.e., less then 10% standard deviation between experimental and predicted results.
Heat-transfer enhancement of two-phase closed thermosyphon using a novel cross-flow condenser
Aghel, Babak; Rahimi, Masoud; Almasi, Saeed
2017-03-01
The present study reports the heat-transfer performance of a two-phase closed thermosyphon (TPCT) equipped with a novel condenser. Distillated water was used as working fluid, with a volumetric liquid filling ratio of 75 %. An increase in heat flux was used to measure the response of the TPCT, including variations in temperature distribution, thermal resistance, average temperature of each section of TPCT and overall thermal difference. Results show that for various power inputs from 71 to 960 W, the TPCT with the novel condenser had a lower wall-temperature difference between the evaporator and condenser sections than did the unmodified TPCT. Given the experimental data for heat-transfer performance, it was found that the thermal resistance in the TPCT equipped with the proposed condenser was between 10 and 17 % lower than in the one without.
Pion condensation and neutron star dynamics
International Nuclear Information System (INIS)
Kaempfer, B.
1983-01-01
The question of formation of pion condensate via a phase transition in nuclear matter, especially in the core of neutron stars is reviewed. The possible mechanisms and the theoretical restrictions of pion condensation are summarized. The effects of ultradense equation of state and density jumps on the possible condensation phase transition are investigated. The possibilities of observation of condensation process are described. (D.Gy.)
Cooling performance and evaluation of automotive refrigeration system for a passenger car
Prajitno, Deendarlianto, Majid, Akmal Irfan; Mardani, Mahardeka Dhias; Wicaksono, Wendi; Kamal, Samsul; Purwanto, Teguh Pudji; Fauzun
2016-06-01
A new design of automotive refrigeration system for a passenger car was proposed. To ensure less energy consumption and optimal thermal comfort, the performance of the system were evaluated. This current research was aimed to evaluate the refrigeration characteristics of the system for several types of cooling load. In this present study, a four-passenger wagon car with 1500 cc gasoline engine that equipped by a belt driven compressor (BDC) was used as the tested vehicle. To represent the tropical condition, a set of lamps and wind sources are installed around the vehicle. The blower capacity inside a car is varied from 0.015 m/s to 0.027 m/s and the compressor speed is varied at variable 820, 1400, and 2100 rpm at a set temperature of 22°C. A set of thermocouples that combined by data logger were used to measure the temperature distribution. The system uses R-134a as the refrigerant. In order to determine the cooling capacity of the vehicle, two conditions were presented: without passengers and full load conditions. As the results, cooling capacity from any possible heating sources and transient characteristics of temperature in both systems for the cabin, engine, compressor, and condenser are presented in this work. As the load increases, the outlet temperature of evaporator also increases due to the increase of condensed air. This phenomenon also causes the increase of compressor work and compression ratio which associated to the addition of specific volume in compressor inlet.
Natural Occurrence of Aldol Condensation Products in Valencia Orange Oil.
Abreu, Ingo; Da Costa, Neil C; van Es, Alfred; Kim, Jung-A; Parasar, Uma; Poulsen, Mauricio L
2017-12-01
Cold pressed orange oils contain predominantly d-limonene (approximately 95%) and various other lower concentration monoterpenes, sesquiterpenes, sinensals plus 3 key aliphatic aldehydes: hexanal, octanal. and decanal. The aldol self-condensation products or "dimers" for each aldehyde have been postulated as being present at low concentrations in the oil. However, to date only the hexanal dimer has been previously reported. In this paper, cold pressed Valencia orange oil was fractionally distilled/folded and analyzed by GC and high resolution GC-MS to detect these compounds on 2 different capillary column phases. Subsequently the hexanal, octanal, and decanal self-aldol condensation products, 2-butyl-2-octenal, 2-hexyl-2-decenal, and 2-octyl-2-dodecenal, respectively, were detected in the folded oil. These predominantly trans configuration isomeric compounds were synthesized, to confirm them as being present in nature and evaluated organoleptically by a panel of evaluators. To further confirm the mechanism of their formation, the enriched oil was made into a simple beverage to show the effect on the formation of these aldol compounds under acidic conditions. Finally aliphatic aldehydes from hexanal to undecanal were reacted together in various combinatorial pairs to give an additional 33 self and mixed aldol condensation products, some of which were also detected in the folded oil. This paper discloses the structural elucidation and synthesis of 8 novel aldol condensation products found at trace concentrations in citrus and leading to a further 31 mass spectrally determined aldol products. Sensory evaluations and application of some of these components were demonstrated in a model citrus beverage. © 2017 Institute of Food Technologists®.
Contribution to the study of unsteady condensation in transonic flow
International Nuclear Information System (INIS)
Collignan, B.; Laali, A.R.
1993-12-01
The aim of this thesis is the study of transonic steam flows with condensation, especially at high pressure. This study includes a numerical part an experimental one. The modelling has consisted of introducing a spontaneous condensation model in a one-dimensional Euler code using steam-water thermodynamic tables. Calculations, performed with this code, are in good agreement with experimental results at low pressure. The experimental study has been undertaken on a high pressure experimental loop installed at the Bugey nuclear power plant. We have studied steam flows in nozzles. The results obtained show that a partial heterogeneous condensation occurs in these flows. This proportion is stronger if the expansion rate of the flow is low and if the inlet pressure is high. However, a correction factor is obtained for high pressure nucleation rate model from experimental results. No unsteady condensation has been observed for flows between 15 bars and 50 bars with the steam available at Bugey power plant. (authors). figs., 71 refs., 6 annexes
International Nuclear Information System (INIS)
Choi, Y. S.; Jeong, W. T.; Shon, S. Y.; Kim, M. H.
2003-01-01
Moisture Separator Reheater is one of the most important equipment for the integrity of low pressure turbine and the total efficiency of the nuclear power plant, It supplies the dry steam to low pressure turbine after separation of moisture and reheating the wet steam out of high pressure turbine. This equipment is always operated under severe conditions, therefore it should be carefully maintained for safe operation and operating confidence. After replacement low pressure reheater of moister separator reheater on domestic nuclear power plant, there was MSR performance degradation and vibration of condensate drain line. So I found out root cause and commented a solution, site people modified the equipment. Finally I concluded the performanc of MSR was good condition, after I inspected the equipment and evaluated the performance of MSR
Mathematical simulation of the process of condensing natural gas
Tastandieva, G. M.
2015-01-01
Presents a two-dimensional unsteady model of heat transfer in terms of condensation of natural gas at low temperatures. Performed calculations of the process heat and mass transfer of liquefied natural gas (LNG) storage tanks of cylindrical shape. The influence of model parameters on the nature of heat transfer. Defined temperature regimes eliminate evaporation by cooling liquefied natural gas. The obtained dependence of the mass flow rate of vapor condensation gas temperature. Identified the possibility of regulating the process of "cooling down" liquefied natural gas in terms of its partial evaporation with low cost energy.
Chiral condensate from the twisted mass Dirac operator spectrum
International Nuclear Information System (INIS)
Cichy, Krzysztof; Jansen, Karl; Cyprus Univ., Nicosia
2013-03-01
We present the results of our computation of the chiral condensate with N f =2 and N f =2+1+1 flavours of maximally twisted mass fermions. The condensate is determined from the Dirac operator spectrum, applying the spectral projector method proposed by Giusti and Luescher. We use 3 lattice spacings and several quark masses at each lattice spacing to reliably perform the chiral and continuum extrapolations. We study the effect of the dynamical strange and charm quarks by comparing our results for N f =2 and N f =2+1+1 dynamical flavours.
Condensate polisher application for PWR steam generator corrosion control
International Nuclear Information System (INIS)
Sawochka, S.G.; Leibovitz, J.; Siegwarth, D.P.; Pearl, W.L.
1981-01-01
The evolution of corrosion attack modes particularly in recirculating U-tube PWR steam generators has dictated a thorough review of the advantages and disadvantages of condensate polishing. Analytical modeling techniques to qualitatively predict crevice chemistry variations resulting from steam generator bulk water variations have allowed valuable insights to be developed. Modeling results complemented by steam generator and laboratory corrosion data will be employed to set condensate demineralizer effluent specifications consistent with control of steam generator corrosion. Laboratory and plant studies are being performed to demonstrate achievability of necessary effluent specifications. (author)
Microbiologically influenced corrosion in condenser water boxes at Crystal River-3
International Nuclear Information System (INIS)
Hayner, G.O.; Pope, D.H.; Crane, B.E.
1988-01-01
During the spring of 1986, several welds in the lower half of the condenser inlet water boxes at Crystal River-3 (CR-3) were found to be seeping seawater. The leakage produced red-brown and black-green colored deposits on the outside surface of the water boxes. The welds in affected areas were not uniformly attacked, and the severity of attack varied between water boxes; however, there were instances of attack on each type of pressure-retaining weld in the affected regions. Weld seepage was also seen on the outside of the inlet piping to the water boxes. A few small pin holes were seen in the base metal of the water boxes not associated with welds. In this paper the authors report the results of examinations performed at both the CR-3 site and at The Babcock and Wilcox Company Lynchburt Research Center (LRC). The inside of a water box and the exterior of the condenser inlet piping were visually inspected at the Cr-3 site. Nodules inside the water box were probed and examined. Parts of nodules were collected and microscopically examined for bacteria. Two corrosion-deposit samples removed from condenser instrument piping and the condenser inlet piping were chemically analyzed at the LRC. Four pipe samples removed from the condenser instrument piping were destructively examined at the LRC. This work included visual inspection, metallographic, scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS) examinations performed on selected locations of the piping samples
The physics of exciton-polariton condensates
Lagoudakis, Konstantinos
2013-01-01
In 2006 researchers created the first polariton Bose-Einstein condensate at 19K in the solid state. Being inherently open quantum systems, polariton condensates open a window into the unpredictable world of physics beyond the “fifth state of matter”: the limited lifetime of polaritons renders polariton condensates out-of-equilibrium and provides a fertile test-bed for non-equilibrium physics. This book presents an experimental investigation into exciting features arising from this non-equilibrium behavior. Through careful experimentation, the author demonstrates the ability of polaritons to synchronize and create a single energy delocalized condensate. Under certain disorder and excitation conditions the complete opposite case of coexisting spatially overlapping condensates may be observed. The author provides the first demonstration of quantized vortices in polariton condensates and the first observation of fractional vortices with full phase and amplitude characterization. Finally, this book investigate...
Gundersen, Pål Lee
2013-01-01
Master's thesis in Petroleum engineering Gas condensate flow behaviour below the dew point in low permeable formations can make accurate fluid sampling a difficult challenge. The objective of this study was to investigate the producing oil-gas ratio behaviour in the infinite-acting period for a low permeable gas condensate reservoir. Compositional isothermal flow simulations were performed using a single-layer, radial and two-dimensional, gas condensate reservoir model with low permeabili...
Characteristics of transonic moist air flows around butterfly valves with spontaneous condensation
Directory of Open Access Journals (Sweden)
A.B.M. Toufique Hasan
2015-06-01
Full Text Available Effects of spontaneous condensation of moist air on the shock wave dynamics around butterfly valves in transonic flows are investigated by experimental and numerical simulations. Two symmetric valve disk shapes namely- a flat rectangular plate and a mid-plane cross-section of a prototype butterfly valve have been studied in the present research. Results showed that in case with spontaneous condensation, the root mean square of pressure oscillation (induced by shock dynamics is reduced significantly with those without condensation for both shapes of the valves. Moreover, local aerodynamic moments were reduced in case with condensation which is considered to be beneficial in torque requirement in case of on/off applications of valves as flow control devices. However, total pressure loss was increased with spontaneous condensation in both the valves. Furthermore, the disk shape of a prototype butterfly valve showed better aerodynamic performances compared to flat rectangular plate profile in respect of total pressure loss and vortex shedding frequency in the wake region.
Condensation heat transfer of a feed-water heater and improvement of its performance
International Nuclear Information System (INIS)
Takamori, Kazuhide; Murase, Michio; Baba, Yoshikazu; Aihara, Tsuyoshi
1995-01-01
In this study, a condensation heat transfer model, coupled with a three-dimensional two-phase flow analysis, was developed. In the heat transfer model, the liquid film flow rate on the heat transfer tubes was calculated by a mass balance equation and the liquid film thickness was calculated from the liquid film flow rate using Nusselt's laminar flow model and Fujii's equation for the steam velocity effect. The model was verified by condensation heat transfer experiments. In the experiments, 112 horizontal, staggered tubes with an outer diameter of 16mm and length of 0.55m were used. The calculated over-all heat transfer coefficients agreed with the data within ±5% under the inlet quality conditions of 13-100%. Based on a three-dimensional two-phase flow analysis, an improved feed-water heater with support plates, which have flow holes between the upper and lower tube bundles, was designed. The total heat exchange capacity of the improved feed-water heater increased about 6%. (author)
Transient direct-contact condensation on liquid droplets
International Nuclear Information System (INIS)
Pasamehmetoglu, K.O.; Nelson, R.A.
1987-01-01
In this paper, direct-contact condensation on subcooled liquid droplets is studied in two parts. In the first part, simple design correlations for the condensation in a steady environment are developed based upon a conduction model. These correlations include the convective heat-transfer coefficient, condensation rate, total condensation, and the droplet-thermalization time. In the second part of the paper, the effect of a time-dependent saturation temperature on the condensation process is investigated. A rapid decrease in saturation temperature is typical of condensation environments in which the steam-supply rate is limited and condensation-induced depressurization becomes important. Design correlations are developed for condensation in an environment in which the saturation temperature decreases linearly with time. These correlations are graphically compared to the design correlations of the first part through a quasi-steady approach. The error associated with this approach is quantified as a function of the rate of change of the saturation temperature
Computations for a condenser. Experimental results
International Nuclear Information System (INIS)
Walden, Jean.
1975-01-01
Computations for condensers are presented with experimental results. The computations are concerned with the steam flux at the condenser input, and inside the tube bundle. Experimental results are given for the flux inside the condenser sleeve and the flow passing through the tube bundle [fr
Charge Screening in a Charged Condensate
International Nuclear Information System (INIS)
Gabadadze, Gregory; Rosen, Rachel A.
2009-01-01
We consider a highly dense system of helium-4 nuclei and electrons in which the helium-4 nuclei have condensed. We present the condensation mechanism in the framework of low energy effective field theory and discuss the screening of electric charge in the condensate.
International Nuclear Information System (INIS)
Snoke, David; Littlewood, Peter
2010-01-01
Most students of physics know about the special properties of Bose-Einstein condensates (BECs) as demonstrated in the two best-known examples: superfluid helium-4, first reported in 1938, and condensates of trapped atomic gases, first observed in 1995. (See the article by Wolfgang Ketterle in PHYSICS TODAY, December 1999, page 30.) Many also know that superfluid 3 He and superconducting metals contain BECs of fermion pairs. An underlying principle of all those condensed-matter systems, known as quantum fluids, is that an even number of fermions with half-integer spin can be combined to make a composite boson with integer spin. Such composite bosons, like all bosons, have the property that below some critical temperature--roughly the temperature at which the thermal de Broglie wavelength becomes comparable to the distance between the bosons--the total free energy is minimized by having a macroscopic number of bosons enter a single quantum state and form a macroscopic, coherent matter wave. Remarkably, the effect of interparticle repulsion is to lead to quantum mechanical exchange interactions that make that state robust, since the exchange interactions add coherently.
Comparison of condensation correlations in CATHARE for modelling isolation condenser experiment
International Nuclear Information System (INIS)
Sorjonen, J.; Kalli, H.
1996-01-01
CATHARE is a thermal-hydraulic computer code developed at the Centre d'Etudes Nucleaires de Grenoble (CENG) for nuclear power plant safety analysis. Behaviour of a new Cathare condensation correlation have been studied. The code has been applied to Isolation Condenser (IC) experiment conducted in PIPER-ONE facility. PIPER-ONE simulates a General Electric BWR-6 with volume and height scaling ratios 1/2200 and 1/1, respectively. The facility is installed at Dipartimento di Costruzioni Meccaniche e Nucleari of Pisa University. The facility was equipped with an once-through heat exchanger immersed in a pool of ambient temperature water, installed roughly 10 m above the core, in the aim to reproduce qualitatively the phenomenologies expected for Isolation Condenser in the Simplified BWR (SBWR). Experiment PO-IC-02 included two subsequent power levels with initial pressure of 5.1 MPa. The IC was active during the whole experiment except in the time period between the two different power levels. A previous calculation of above mentioned experiment by Cathare2 V1.3E showed some lacks in the condensation correlation of the code. A new correlation has been developed in Centre d'Etudes Nucleaires de Grenoble (CENG). The new calculation of the PO-IC-02 experiment by Cathare2 Vl.3U 1 with the new correlation gave results consistent with the experiment in the condensing zone of the IC. Also the overall pressure trend was reproduced with estimated heat losses to the environment. A comparison with previously obtained Relap5/Mod3. 1 results is also shown in the present document. (author) (18 refs.)
Gas adsorption and capillary condensation in nanoporous alumina films
Energy Technology Data Exchange (ETDEWEB)
Casanova, Felix; Chiang, Casey E; Li, Chang-Peng; Roshchin, Igor V; Schuller, Ivan K [Physics Department, University of California-San Diego, La Jolla, CA 92093 (United States); Ruminski, Anne M; Sailor, Michael J [Department of Chemistry and Biochemistry, University of California-San Diego, La Jolla, CA 92093 (United States)], E-mail: casanova@physics.ucsd.edu
2008-08-06
Gas adsorption and capillary condensation of organic vapors are studied by optical interferometry, using anodized nanoporous alumina films with controlled geometry (cylindrical pores with diameters in the range of 10-60 nm). The optical response of the film is optimized with respect to the geometric parameters of the pores, for potential performance as a gas sensor device. The average thickness of the adsorbed film at low relative pressures is not affected by the pore size. Capillary evaporation of the liquid from the nanopores occurs at the liquid-vapor equilibrium described by the classical Kelvin equation with a hemispherical meniscus. Due to the almost complete wetting, we can quantitatively describe the condensation for isopropanol using the Cohan model with a cylindrical meniscus in the Kelvin equation. This model describes the observed hysteresis and allows us to use the adsorption branch of the isotherm to calculate the pore size distribution of the sample in good agreement with independent structural measurements. The condensation for toluene lacks reproducibility due to incomplete surface wetting. This exemplifies the relevant role of the fluid-solid (van der Waals) interactions in the hysteretic behavior of capillary condensation.
Gas adsorption and capillary condensation in nanoporous alumina films
International Nuclear Information System (INIS)
Casanova, Felix; Chiang, Casey E; Li, Chang-Peng; Roshchin, Igor V; Schuller, Ivan K; Ruminski, Anne M; Sailor, Michael J
2008-01-01
Gas adsorption and capillary condensation of organic vapors are studied by optical interferometry, using anodized nanoporous alumina films with controlled geometry (cylindrical pores with diameters in the range of 10-60 nm). The optical response of the film is optimized with respect to the geometric parameters of the pores, for potential performance as a gas sensor device. The average thickness of the adsorbed film at low relative pressures is not affected by the pore size. Capillary evaporation of the liquid from the nanopores occurs at the liquid-vapor equilibrium described by the classical Kelvin equation with a hemispherical meniscus. Due to the almost complete wetting, we can quantitatively describe the condensation for isopropanol using the Cohan model with a cylindrical meniscus in the Kelvin equation. This model describes the observed hysteresis and allows us to use the adsorption branch of the isotherm to calculate the pore size distribution of the sample in good agreement with independent structural measurements. The condensation for toluene lacks reproducibility due to incomplete surface wetting. This exemplifies the relevant role of the fluid-solid (van der Waals) interactions in the hysteretic behavior of capillary condensation
Gas adsorption and capillary condensation in nanoporous alumina films.
Casanova, Fèlix; Chiang, Casey E; Li, Chang-Peng; Roshchin, Igor V; Ruminski, Anne M; Sailor, Michael J; Schuller, Ivan K
2008-08-06
Gas adsorption and capillary condensation of organic vapors are studied by optical interferometry, using anodized nanoporous alumina films with controlled geometry (cylindrical pores with diameters in the range of 10-60 nm). The optical response of the film is optimized with respect to the geometric parameters of the pores, for potential performance as a gas sensor device. The average thickness of the adsorbed film at low relative pressures is not affected by the pore size. Capillary evaporation of the liquid from the nanopores occurs at the liquid-vapor equilibrium described by the classical Kelvin equation with a hemispherical meniscus. Due to the almost complete wetting, we can quantitatively describe the condensation for isopropanol using the Cohan model with a cylindrical meniscus in the Kelvin equation. This model describes the observed hysteresis and allows us to use the adsorption branch of the isotherm to calculate the pore size distribution of the sample in good agreement with independent structural measurements. The condensation for toluene lacks reproducibility due to incomplete surface wetting. This exemplifies the relevant role of the fluid-solid (van der Waals) interactions in the hysteretic behavior of capillary condensation.
Characterization of spacecraft humidity condensate
Muckle, Susan; Schultz, John R.; Sauer, Richard L.
1994-01-01
When construction of Space Station Freedom reaches the Permanent Manned Capability (PMC) stage, the Water Recovery and Management Subsystem will be fully operational such that (distilled) urine, spent hygiene water, and humidity condensate will be reclaimed to provide water of potable quality. The reclamation technologies currently baselined to process these waste waters include adsorption, ion exchange, catalytic oxidation, and disinfection. To ensure that the baseline technologies will be able to effectively remove those compounds presenting a health risk to the crew, the National Research Council has recommended that additional information be gathered on specific contaminants in waste waters representative of those to be encountered on the Space Station. With the application of new analytical methods and the analysis of waste water samples more representative of the Space Station environment, advances in the identification of the specific contaminants continue to be made. Efforts by the Water and Food Analytical Laboratory at JSC were successful in enlarging the database of contaminants in humidity condensate. These efforts have not only included the chemical characterization of condensate generated during ground-based studies, but most significantly the characterization of cabin and Spacelab condensate generated during Shuttle missions. The analytical results presented in this paper will be used to show how the composition of condensate varies amongst enclosed environments and thus the importance of collecting condensate from an environment close to that of the proposed Space Station. Although advances were made in the characterization of space condensate, complete characterization, particularly of the organics, requires further development of analytical methods.
46 CFR 56.50-35 - Condensate pumps.
2010-10-01
... APPURTENANCES Design Requirements Pertaining to Specific Systems § 56.50-35 Condensate pumps. Two means shall be provided for discharging the condensate from the main condenser, one of which shall be mechanically... suction from the condenser and a discharge to the feed tank, it may be accepted as an independent...
International Nuclear Information System (INIS)
Macedo, Luiz Alberto; Torres, Walmir Maximo
2009-01-01
Horizontal heat exchangers are used in advanced light water nuclear reactors in their passive cooling systems, such as residual heat removal (RHRS) and passive containment cooling system (PCCS). Condensation studies of steam and noncondensable gases mixtures in these heat exchangers are very important due to the phenomena multidimensional nature and the condensate stratification effects. This work presents a comparison between simulation results and experimental data in steady state conditions for some inlet pressure, steam and noncondensable gases (air) inlet mass fractions. The test section is three meters long and consists of two concentric tubes containing pressure, temperature and flow rate sensors. The internal tube, called condenser, contains steam-air mixture flow and external tube is a counter current cooler with water flow rate at low temperature. This test section was modeled and simulations were performed with RELAP5 code. Experimental tests were carried out for 200 to 400 kPa inlet pressure and 5, 10, 15 and 20% of inlet air mass fractions. Comparisons between experimental data and simulation results are presented for 200 and 400 kPa pressure conditions and showed good agreement. However, for 400 kPa inlet steam pressure and inlet air mass fractions above 5%, the simulated temperatures are lower than the experimental data at the final third from the inlet condenser tube, indicating a code overestimation of heat transfer coefficient. New correlations for heat transfer coefficient in these steam-air conditions must be theoretical and experimentally studied and implemented in RELAP5 code for better representing the condensation phenomena. (author)
Energy Technology Data Exchange (ETDEWEB)
Fu, Wen [Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Li, Xiaowei, E-mail: lixiaowei@tsinghua.edu.cn [Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Wu, Xinxin [Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Corradini, Michael L. [Department of Engineering Physics, University of Wisconsin-Madison, 1500 Engineering Drive, Madison, WI 53706 (United States)
2016-02-15
Highlights: • Gas mixture convective condensation in vertical tubes were simulated using FLUENT code. • The simulation results matched well with experimental data. • The detailed velocity field and species distribution were investigated. • The suction factors predicted by CFD models were compared with the classical correlations. • The effects of air and helium on steam condensation were compared. - Abstract: Steam condensation is degraded when non-condensable gases are present. Convective condensation of steam–air mixture and steam–helium mixture in vertical tubes were simulated using the CFD code FLUENT. The condensation process was modeled by defining source terms for the mass, momentum, species and energy conservation equations. Several cases with various steam mass fractions were simulated, the results matched well with the experimental data. Detailed velocity field and species distribution were investigated. The radial velocity was clearly represented, and the suction effect was modeled, which needs to be accounted for when using the heat and mass transfer analogy theory. The Nusselt and Sherwood numbers predicted by CFD models were compared with the classical correlations, and the suction effects were analyzed. The suction effect is proportional to steam mass fraction, while the suction factor is little affected by the Reynolds number. For forced convection flow in this work, the buoyant force can be neglected, so the larger diffusion coefficient of steam–helium mixture would improve the steam condensation compared to steam–air mixture. The condensation mass fluxes of steam–helium mixture and steam–air mixture are almost the same at relatively high steam inlet molar fraction (≥90%).
International Nuclear Information System (INIS)
Meloni, P.
2001-01-01
ENEA (Italy) in co-operation with CEA (France) has carried out an R and D activity aimed at increasing the reliability of Decay Heat Removal (DHR) passive systems that implement in-pool heat exchangers. The main outcome reached was the definition of a device, called Thermal Valve (TV), able to avoid the installation of mechanical valve on the primary circuit, thus reducing thermalmechanical constrains and thermal-hydraulic instabilities. This paper presents a preliminary assessment performed with CATHARE of this innovative device. In the first part the code capability to simulate in-pool heat exchangers is verified against experimental data of the PANDA facility, that are available within the frame of the ISP 42. In the second part a CATHARE calculation showing the performances of the PANDA passive condenser with TV (start-up and shutdown) is described.(author)
Preparatory studies for modelling steam condensation on soluble aerosols
International Nuclear Information System (INIS)
Dunbar, I.H.
1988-01-01
Of the fission products which would be released from the core of an LWR in the event of a severe accident, only the noble gases and possibly some of the iodine (depending on chemical form) are likely not to be in the form of aerosols when they reach the containment building atmosphere. Therefore in order to predict the extent of fission product retention on containment building internal structures, one needs to have a good understanding of aerosol deposition processes and of the factors which affect them. Following a severe accident in an LWR, a major component of the containment atmosphere will be steam. If the thermodynamic conditions allow condensation of this steam, this condensation is most likely to occur on the aerosol particles. A major component of the aerosol formed during the in-vessel release following a severe reactor accident will be fission product caesium. It is believed that much of this will enter the containment in the form of the hydroxide which has a great affinity for water, so particle growth due to steam condensation is likely to be a very important mechanism for retaining radioactive caesium within the containment builing. The author provides a systematic review of the basic chemical and physical issues which must be addressed if the phenomena are to be modelled accurately, and gives recommendations on how computer models of condensation onto soluble aerosols should be constructed. He proposes also to perform a systematic review of the existing literature and to perform small-scale thermodynamic experiments wherever important gaps in the data base are discovered
Numerical study of a double-slope solar still coupled with capillary film condenser in south Algeria
International Nuclear Information System (INIS)
Belhadj, Mohamed Mustapha; Bouguettaia, Hamza; Marif, Yacine; Zerrouki, Moussa
2015-01-01
Highlights: • This is a numerical work on solar stills in the desert of Algeria using solar energy. • Solar stills can secure fresh water to low density remote desert agglomerations. • The yield was improved by coupling a solar still with a capillary film condenser. • The distilled water production increases with the reduction in flow feed saline water. • The yield varies conversely with the distance between the two condensing plates. - Abstract: The effect of joining a condensation cell to a single-basin double slope solar still was investigated numerically. Direct solar radiation heated the saline water then evaporated. A fraction of the resulting vapor is condensed on the inner glass cover plate and the rest on the outer metal plate. Solar radiation, ambient temperature and the temperatures at different system components were monitored. The performance of the system was evaluated and compared to that of a conventional solar still under the same meteorological conditions. The proposed prototype functioned perfectly and its daily yield reached 7.15 kg m −2 d −1 . Results show that the productivity of the present system was about 60% higher than that of the conventional and capillary film types. The contributions of the glass cover, metal plate and condenser plate are 43%, 18% and 39% of the total distillate yield respectively. It was noticed that the productivity of the capillary film solar still was sensitive to the mass flow of the feeding water. It was also found that the absorptivity coefficient and the diffusion gap have significant effect on distillate production of the system
Karimi, Amir
1991-01-01
NASA's effort for the thermal environmental control of the Space Station Freedom is directed towards the design, analysis, and development of an Active Thermal Control System (ATCS). A two phase, flow through condenser/radiator concept was baselined, as a part of the ATCS, for the radiation of space station thermal load into space. The proposed condenser rejects heat through direct condensation of ATCS working fluid (ammonia) in the small diameter radiator tubes. Analysis of the condensation process and design of condenser tubes are based on the available two phase flow models for the prediction of flow regimes, heat transfer, and pressure drops. The prediction formulas use the existing empirical relationships of friction factor at gas-liquid interface. An attempt is made to study the stability of interfacial waves in two phase annular flow. The formulation is presented of a stability problem in cylindrical coordinates. The contribution of fluid viscosity, surface tension, and transverse radius of curvature to the interfacial surface is included. A solution is obtained for Kelvin-Helmholtz instability problem which can be used to determine the critical and most dangerous wavelengths for interfacial waves.
García-Hernández, Cesar; Arece-García, Javier; Rojo-Rubio, Rolando; Mendoza-Martínez, German David; Albarrán-Portillo, Benito; Vázquez-Armijo, José Fernando; Avendaño-Reyes, Leonel; Olmedo-Juárez, Agustín; Marie-Magdeleine, Carine; López-Leyva, Yoel
2017-01-01
Forty-five Pelibuey sheep were experimentally infested with nematodes to evaluate the effect of three free condensed tannin (FCT) levels of Lysiloma acapulcensis on fecal egg counts (FECs), packed cell volumes (PCV), ocular mucosa colors (OMC), average daily gain (ADG), and adult nematode count. Five treatments were used: 12.5, 25.0, and 37.5 mg of FCT kg -1 of body weight (BW); sterile water (control); and ivermectine (0.22 mg kg -1 of BW) as chemical group. The data were processed through repeated measurement analysis. Even though the three FCT doses decreased (P < 0.05) the FEC, the highest reduction was obtained with 37.5 mg kg -1 of BW. No differences were observed in PCV and OMC. Higher ADG (P < 0.05) was observed with 37.5 mg kg -1 of BW of FCT. The count of adult nematodes (females and males) in the higher dose of FCT was similar to chemical treatment. Dose of 37.5 mg kg -1 of BW decreased the parasite infection and improved the lamb performance. Therefore, this dose could be used as a nutraceutic product in sheep production.
Environmental sustainability by adoption of alternate cooling media for condenser cooling
International Nuclear Information System (INIS)
Gandhi, Jaymin; Patel, Nilesh
2015-01-01
Water having ability to dissolve most substances and to support biological life, every cooling water system in power plant is subjected to potential operational problems which are mainly corrosion, scaling and biological fouling. Control of cooling water chemistry is very critical in preventing above said problems. In view of scarcity of water and looking into the future trends in the environment protection, water media can be replaced with air. Having such concept in thermal and combined cycle power plants, use of Air-cooled condenser (ACC) for Nuclear power plant may be explored. During last decade number of installations with ACC also increased, largely in response to the growing attention being paid to environmental concerns as well of water scarcity. The rising importance of 'Save Water and Environment', calls for a broader understanding of the design and application principles involved for ACC. This paper identifies the basic configurations of air cooled condensers used in the power industry together with their merits and demerits when compared to those exhibited by traditional steam surface condensers including environmental and corrosion issues. Several factors that affect the performance of air-cooled condensers are described in detail, especially the consequences that result from the fouling of the finned-tubes. To rectify the degradations in performance that result from external tube fouling, a number of cleaning procedures are described. Due to relatively high cost of sweet water and large requirement of sea water, Air cooled condenser may become viable option in future. (author)
Chiral condensate from the twisted mass Dirac operator spectrum
Energy Technology Data Exchange (ETDEWEB)
Cichy, Krzysztof [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany). John von Neumann-Inst. fuer Computing NIC; Poznan Univ. (Poland). Faculty of Physics; Garcia-Ramos, Elena [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany). John von Neumann-Inst. fuer Computing NIC; Humboldt-Universitaet, Berlin (Germany); Jansen, Karl [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany). John von Neumann-Inst. fuer Computing NIC; Cyprus Univ., Nicosia (Cyprus). Dept. of Physics; Collaboration: European Twisted Mass Collaboration
2013-03-15
We present the results of our computation of the chiral condensate with N{sub f}=2 and N{sub f}=2+1+1 flavours of maximally twisted mass fermions. The condensate is determined from the Dirac operator spectrum, applying the spectral projector method proposed by Giusti and Luescher. We use 3 lattice spacings and several quark masses at each lattice spacing to reliably perform the chiral and continuum extrapolations. We study the effect of the dynamical strange and charm quarks by comparing our results for N{sub f}=2 and N{sub f}=2+1+1 dynamical flavours.
Mathematical simulation of the process of condensing natural gas
Directory of Open Access Journals (Sweden)
Tastandieva G.M.
2015-01-01
Full Text Available Presents a two-dimensional unsteady model of heat transfer in terms of condensation of natural gas at low temperatures. Performed calculations of the process heat and mass transfer of liquefied natural gas (LNG storage tanks of cylindrical shape. The influence of model parameters on the nature of heat transfer. Defined temperature regimes eliminate evaporation by cooling liquefied natural gas. The obtained dependence of the mass flow rate of vapor condensation gas temperature. Identified the possibility of regulating the process of “cooling down” liquefied natural gas in terms of its partial evaporation with low cost energy.
Condensing boiler applications in the process industry
International Nuclear Information System (INIS)
Chen, Qun; Finney, Karen; Li, Hanning; Zhang, Xiaohui; Zhou, Jue; Sharifi, Vida; Swithenbank, Jim
2012-01-01
Major challenging issues such as climate change, energy prices and fuel security have focussed the attention of process industries on their energy efficiency and opportunities for improvement. The main objective of this research study was to investigate technologies needed to exploit the large amount of low grade heat available from a flue gas condensing system through industrial condensing boilers. The technology and application of industrial condensing boilers in various heating systems were extensively reviewed. As the condensers require site-specific engineering design, a case study was carried out to investigate the feasibility (technically and economically) of applying condensing boilers in a large scale district heating system (40 MW). The study showed that by recovering the latent heat of water vapour in the flue gas through condensing boilers, the whole heating system could achieve significantly higher efficiency levels than conventional boilers. In addition to waste heat recovery, condensing boilers can also be optimised for emission abatement, especially for particle removal. Two technical barriers for the condensing boiler application are corrosion and return water temperatures. Highly corrosion-resistant material is required for condensing boiler manufacture. The thermal design of a 'case study' single pass shell-and-tube condensing heat exchanger/condenser showed that a considerable amount of thermal resistance was on the shell-side. Based on the case study calculations, approximately 4900 m 2 of total heat transfer area was required, if stainless steel was used as a construction material. If the heat transfer area was made of carbon steel, then polypropylene could be used as the corrosion-resistant coating material outside the tubes. The addition of polypropylene coating increased the tube wall thermal resistance, hence the required heat transfer area was approximately 5800 m 2 . Net Present Value (NPV) calculations showed that the choice of a carbon
Coating strategy for enhancing illumination uniformity in a lithographic condenser
International Nuclear Information System (INIS)
Gaines, D.P.; Vernon, S.P.; Sommargren, G.E.; Kania, D.R.
1995-01-01
A three-element Koehler condenser system has been fabricated, characterized, and integrated into an EUV lithographic system. The multilayer coatings deposited on the optics were designed to provide optimal radiation transport efficiency and illumination uniformity. Extensive EUV characterization measurements performed on the individual optics and follow-on system measurements indicated that the condenser was operating close to design goals. Multilayer d-spacings were within 0.05 nm of specifications, and reflectances were approximately 60%. Illumination uniformity was better than ±10%. The broadband transport efficiency was 11%
International Nuclear Information System (INIS)
Sakurai, Manabu; Hirayama, Fumio; Kurosawa, Setsumi; Yoshikawa, Jun; Hosaka, Seiichi.
1992-01-01
The present invention enables to separate and remove 14 C as CO 3 - ions without condensation in a vapor condensation can of a nuclear facility. That is, the vapor condensation device of the nuclear facility comprises (1) a spray pipe for spraying an acidic aqueous solution to the evaporation surface of an evaporation section, (2) a spray pump for sending the acidic aqueous solution to the spray pipe, (3) a tank for storing the acidic aqueous solution, (4) a pH sensor for detecting pH of the evaporation section, (5) a pH control section for controlling the spray pump, depending on the result of the detection of the pH sensor. With such a constitution, the pH of liquid wastes on the vaporization surface is controlled to 7 by spraying an aqueous solution of dilute sulfuric acid to the evaporation surface, thereby enabling to increase the transfer rate of 14 C to condensates to 60 to 70%. If 14 C is separated and removed as a CO 2 gas from the evaporation surface, the pH of the liquid wastes returns to the alkaline range of 9 to 10 and the liquid wastes are returned to a heating section. The amount of spraying the aqueous solution of dilute sulfuric acid can be controlled till the pH is reduced to 5. (I.S.)
Fluegas condensation of domestic fuels. Kotimaisten polttoaineiden savukaasulauhdutus
Energy Technology Data Exchange (ETDEWEB)
Kankkunen, A; Fagerholm, N E
1988-01-01
The suitability of domestic fuel for condensation heat recovery was studied. With the developed computer program, enthalpies of flue gas as function of temperature were computed and also the theoretical advandages aquired by condensation were compared with different fuels. The maximal advantages of condensation were 39 % with wooden chips and 31 % with peat. The domestic fuels were found to be useful for condensation heat recovery because of the high water content and the high dewpoint of flu egas. Condensation was found to have a purifying effect on flue gases. It was found experimentaly that 30 % the sulfur of the peat dissolved to the condensed liquid. The composition of condensed liquid of peat- and wooden chip flue gases was studied to find out the corrosion and enviromental effects. The risk of corrosion to metallic heat exhanger was concluded from the compositio of peat condensat. Chip condensate was found to be almost neutral. Normally the condensate liquids were fit for sewering without aftertreatment. Heat transfer coefficient from flue gases to the wall of the condenser was measured to be 150-170 W/Km{sup 2}. Heat transfer coefficients were three times higher compared to condensing heat transfer.
Capillary-Condenser-Pumped Heat-Transfer Loop
Silverstein, Calvin C.
1989-01-01
Heat being transferred supplies operating power. Capillary-condenser-pumped heat-transfer loop similar to heat pipe and to capillary-evaporator-pumped heat-transfer loop in that heat-transfer fluid pumped by evaporation and condensation of fluid at heat source and sink, respectively. Capillary condenser pump combined with capillary evaporator pump to form heat exchanger circulating heat-transfer fluids in both loops. Transport of heat more nearly isothermal. Thermal stress in loop reduced, and less external surface area needed in condenser section for rejection of heat to heat sink.
International Nuclear Information System (INIS)
Svensson, E.C.
1984-01-01
The Condensate Saga, now halfway through its fifth decade, is reviewed. The recent neutron-scattering work which has at last convincingly established that there is indeed a Bose Condensate in He II is described
Numerical simulation of vortex pyrolysis reactors for condensable tar production from biomass
Energy Technology Data Exchange (ETDEWEB)
Miller, R.S.; Bellan, J. [California Inst. of Tech., Pasadena, CA (United States). Jet Propulsion Lab.
1998-08-01
A numerical study is performed in order to evaluate the performance and optimal operating conditions of vortex pyrolysis reactors used for condensable tar production from biomass. A detailed mathematical model of porous biomass particle pyrolysis is coupled with a compressible Reynolds stress transport model for the turbulent reactor swirling flow. An initial evaluation of particle dimensionality effects is made through comparisons of single- (1D) and multi-dimensional particle simulations and reveals that the 1D particle model results in conservative estimates for total pyrolysis conversion times and tar collection. The observed deviations are due predominantly to geometry effects while directional effects from thermal conductivity and permeability variations are relatively small. Rapid ablative particle heating rates are attributed to a mechanical fragmentation of the biomass particles that is modeled using a critical porosity for matrix breakup. Optimal thermal conditions for tar production are observed for 900 K. Effects of biomass identity, particle size distribution, and reactor geometry and scale are discussed.
Allocation of synchronous condensers for restoration of system short-circuit power
DEFF Research Database (Denmark)
Marrazi, Emanuel; Yang, Guangya; Weinreich-Jensen, Peter
2017-01-01
Modern power systems, employing an increasing number of converter-based renewable energy sources (RES) and decreasing the usage of conventional power plants, are leading to lower levels of short-circuit power and rotational inertia. A solution to this is the employment of synchronous condensers...... in the grid, in order to provide sufficient short-circuit power. This results in the increase of the short-circuit ratio (SCR) at transmission system bus-bars serving as points of interconnection (POI) to renewable generation. Evaluation of the required capacity and grid-location of the synchronous condensers...... by renewable generation. Total cost of synchronous condenser installations in the system is minimized and the SCRs at the POIs of central renewable power plants are strengthened. The method has potential for application on larger grids, aiding grid-integration of RES....
Modelling of film condensation in presence of non condensable gases
International Nuclear Information System (INIS)
Genevieve Geffraye; Dominique Bestion; Vladimir Kalitvianski
2005-01-01
Full text of publication follows: This paper presents recent developments in the modelling of the condensation due to heat removal from a wall with a possible presence of hydrogen, nitrogen, or air. This work is mainly concerned with nuclear reactor safety with particular reference to situations related to new reactor design, cold shutdown state and severe accident analysis. Film condensation of steam in presence of nitrogen and helium in a tube has been investigated in the COTURNE experiment in a rather large range of parameters, pressure (from 0.1 to 7 Mpa), heat flux (0.1 to 6 W/cm 2 ), mass fraction of noncondensable gas (0 to 1) and also in presence of superheated steam. The experiment represents a Steam Generator tube of a Pressurised Water Reactor and can simulate both co-current or countercurrent flow of steam and water.The models are implemented in the CATHARE code used for nuclear reactor thermal-hydraulics. The code uses two mass balance equations for liquid and gas, two momentum balance equations for liquid and gas and two energy balance equations for liquid and gas. Additional mass transport equations can be added for each non condensable gas. Heat transfers from wall to liquid film, from liquid to interface and gas to interface are modelled. The liquid film heat transfer coefficient is first investigated in pure saturated steam conditions in the pressure range from 0.1 to 7 Mpa. The CATHARE film condensation model in pure steam conditions is derived from Chen's correlation. Chen proposes a general correlation for the film condensation, covering the wavy-laminar and the turbulent film regimes and taking into account the interfacial friction effect. A large data base of laminar film regime was used including COTURNE data other available data found in the literature. The analysis of these data base suggests an influence of the liquid Reynolds number, according to the Nusselt theory, and also of the Eoetvoes number, with surface tension effects. A
Doxorubicin hinders DNA condensation promoted by the protein bovine serum albumin (BSA).
Lima, C H M; de Paula, H M C; da Silva, L H M; Rocha, M S
2017-12-01
In this work, we have studied the interaction between the anticancer drug doxorubicin (doxo) and condensed DNA, using optical tweezers. To perform this task, we use the protein bovine serum albumin (BSA) in the working buffer to mimic two key conditions present in the real intracellular environment: the condensed state of the DNA and the abundant presence of charged macromolecules in the surrounding medium. In particular, we have found that, when doxo is previously intercalated in disperse DNA, the drug hinders the DNA condensation process upon the addition of BSA in the buffer. On the other hand, when bare DNA is firstly condensed by BSA, doxo is capable to intercalate and to unfold the DNA condensates at relatively high concentrations. In addition, a specific interaction between BSA and doxo was verified, which significantly changes the chemical equilibrium of the DNA-doxo interaction. Finally, the presence of BSA in the buffer stabilizes the double-helix structure of the DNA-doxo complexes, preventing partial DNA denaturation induced by the stretching forces. © 2017 Wiley Periodicals, Inc.
Lin, Yung-Hao; Lee, Ching-Ting
2017-08-01
High-quality indium gallium zinc aluminum oxide (IGZAO) thin films with various Al contents have been deposited using the vapor cooling condensation method. The electron mobility of the IGZAO films was improved by 89.4% on adding Al cation to IGZO film. The change in the electron concentration and mobility of the IGZAO films was 7.3% and 7.0%, respectively, when the temperature was changed from 300 K to 225 K. These experimental results confirm the high performance and stability of the IGZAO films. The performance stability mechanisms of IGZAO thin-film transistors (TFTs) were investigated in comparison with IGZO TFTs.
Analysis and comparison of biomass pyrolysis/gasification condensates: an interim report
Energy Technology Data Exchange (ETDEWEB)
Elliott, D.C.
1985-09-01
This report provides results of chemical and physical analysis of condensates from eleven biomass gasification and pyrolysis systems. The analyses were performed in order to provide more detailed data concerning these condensates for the different process research groups and to allow a determination of the differences in properties of the condensates as a function of reactor environment. The samples were representative of the various reactor configurations being researched within the Department of Energy, Biomass Thermochemical Conversion program. The condensates included tar phases, aqueous phases and, in some cases, both phases depending on the output of the particular reactor system. The analyses included gross compositional analysis (elemental analysis, ash, moisture), physical characterization (pour point, viscosity, density, heat of combustion, distillation), specific chemical analysis (gas chromatography/mass spectrometry, infrared spectrophotometry, proton and carbon-13 nuclear magnetic resonance spectrometry) and biological activity (Ames assay). The analytical data demonstrate the wide range of chemical composition of the organics recovered in the condensates and suggests a direct relationship between operating temperature and chemical composition of the condensates. A continuous pathway of thermal degradation of the tar components as a function of temperature is proposed. Variations in the chemical composition of the organic components in the tars are reflected in the physical properties of tars and phase stability in relation to water in the condensate. The biological activity appears to be limited to the tars produced at high temperatures as a result of formation of polycyclic aromatic hydrocarbons in high concentrations. 55 refs., 13 figs., 6 tabs.
DEFF Research Database (Denmark)
Bechi, Jacopo
2009-01-01
This paper focuses on some issues about condensates and renormalization in AdS/QCD models. In particular we consider the consistency of the AdS/QCD approach for scale dependent quantities as the chiral condensate questioned in some recent papers and the 4D meaning of the 5D cosmological constant...... in a model in which the QCD is dual to a 5D gravity theory. We will be able to give some arguments that the cosmological constant is related to the QCD gluon condensate....
Bose condensation in (random traps
Directory of Open Access Journals (Sweden)
V.A. Zagrebnov
2009-01-01
Full Text Available We study a non-interacting (perfect Bose-gas in random external potentials (traps. It is shown that a generalized Bose-Einstein condensation in the random eigenstates manifests if and only if the same occurs in the one-particle kinetic-energy eigenstates, which corresponds to the generalized condensation of the free Bose-gas. Moreover, we prove that the amounts of both condensate densities are equal. This statement is relevant for justification of the Bogoliubov approximation} in the theory of disordered boson systems.
Isihara, A
2007-01-01
More than a graduate text and advanced research guide on condensed matter physics, this volume is useful to plasma physicists and polymer chemists, and their students. It emphasizes applications of statistical mechanics to a variety of systems in condensed matter physics rather than theoretical derivations of the principles of statistical mechanics and techniques. Isihara addresses a dozen different subjects in separate chapters, each designed to be directly accessible and used independently of previous chapters. Topics include simple liquids, electron systems and correlations, two-dimensional
International Nuclear Information System (INIS)
Hillebrand, C.D.
1999-05-01
An analysis of the literature on Condensed Matter Physics, with particular emphasis on High Temperature Superconductors, was performed on the contents of the bibliographic database International Nuclear Information System (INIS). Quantitative data were obtained on various characteristics of the relevant INIS records such as subject categories, language and country of publication, publication types, etc. The analysis opens up the possibility for further studies, e.g. on international research co-operation and on publication patterns. (author)
Shams, Bilal; Yao, Jun; Zhang, Kai; Zhang, Lei
2017-08-01
Gas condensate reservoirs usually exhibit complex flow behaviors because of propagation response of pressure drop from the wellbore into the reservoir. When reservoir pressure drops below the dew point in two phase flow of gas and condensate, the accumulation of large condensate amount occurs in the gas condensate reservoirs. Usually, the saturation of condensate accumulation in volumetric gas condensate reservoirs is lower than the critical condensate saturation that causes trapping of large amount of condensate in reservoir pores. Trapped condensate often is lost due to condensate accumulation-condensate blockage courtesy of high molecular weight, heavy condensate residue. Recovering lost condensate most economically and optimally has always been a challenging goal. Thus, gas cycling is applied to alleviate such a drastic loss in resources. In gas injection, the flooding pattern, injection timing and injection duration are key parameters to study an efficient EOR scenario in order to recover lost condensate. This work contains sensitivity analysis on different parameters to generate an accurate investigation about the effects on performance of different injection scenarios in homogeneous gas condensate system. In this paper, starting time of gas cycling and injection period are the parameters used to influence condensate recovery of a five-spot well pattern which has an injection pressure constraint of 3000 psi and production wells are constraint at 500 psi min. BHP. Starting injection times of 1 month, 4 months and 9 months after natural depletion areapplied in the first study. The second study is conducted by varying injection duration. Three durations are selected: 100 days, 400 days and 900 days. In miscible gas injection, miscibility and vaporization of condensate by injected gas is more efficient mechanism for condensate recovery. From this study, it is proven that the application of gas cycling on five-spot well pattern greatly enhances condensate recovery
Dual approaches for defects condensation
Energy Technology Data Exchange (ETDEWEB)
Rougemont, Romulo; Grigorio, Leonardo de Souza; Wotzasek, Clovis [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Guimaraes, Marcelo Santos [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)
2009-07-01
Full text. Due to the fact that the QCD running coupling constant becomes larger as we go into the low energy (or large distance) limit of the theory, a perturbative treatment of its infrared (IR) region is impossible. In particular, a formal mathematical demonstration of color confinement and a complete physical understanding of the exact mechanism that confines quarks and gluons are two missing points in our current knowledge of the IR-QCD. It was known that due to the Meissner effect of expulsion of magnetic fields in a electric condensate that usual superconductors should confine magnetic monopoles. That point led to the conjecture that the QCD vacuum could be a condensate of chromomagnetic monopoles, a dual superconductor (DSC). Such a chromomagnetic condensate should be responsible for the dual Meissner effect which is expected to lead to the confinement of color charges immersed in this medium. In dual superconductor models of color confinement, magnetic monopoles appear as topological defects in points of the space where the abelian projection becomes singular. Also, condensation of other kinds of defects such as vortices in superfluids and line-like defects in solids are responsible for a great variety of phase transitions, which once more proves the relevance of the subject. In the present work we review two methods that allow us to approach the condensation of defects: the Kleinert Mechanism (KM) and the Julia-Toulouse Mechanism (JTM). We show that in the limit where the vortex gauge field goes to zero, which we identify as the signature of the condensation of defects in the dual picture, these are two equivalent dual prescriptions for obtaining an effective theory for a phase where defects are condensed, starting from the fundamental theory defined in the normal phase where defects are diluted. (author)
Growth of condensed particles at fast cooling-down of moist air in a laval nozzle
International Nuclear Information System (INIS)
Krause, B.
1980-01-01
The aim of the investigations was to clarify the uncertainty factors contained in the condensation theories as well as to examine different existing growth laws. The measuring method chosen for the study of the progress of condensation was the measurement of the static pressure along the nozzle axis. The investigation of the condensation products with respect to size and number was performed by means of intensity measurements of scattered laser light. The two parameters initial moisture and cooling speed substantially influencing condensation were varied over a wide range. As the scattering behavior of the ice particles formed as condensation products could be described by the Rayleigh-Debye theory, determination of size and number of the condensing particles at every position of the nozzle axis became possible. For the first time particle growth in the nozzle was studied in detail. The results were compared with a number of growth laws. (orig.) [de
Materials in flue gas condensation plants. Stage 2; Materialval vid roekgaskondensering. Etapp 2
Energy Technology Data Exchange (ETDEWEB)
Nordling, Magnus; Bergman, Gunnar; Baeck, Gustaf; Jacobsson, Karin; Pahverk, Helen; Roemhild, Stefanie
2004-12-01
different methods and techniques which varied depending on the type of material. The FRP and the glass-flake materials were evaluated using visual inspection, microscopic investigation of polished and dye-stained cross sections, determination of mass loss and thickness changes. The laminates were also subjected to mechanical testing. The PP materials were evaluated by so-called OIT determinations (Oxidation Induction Time) and the rubber material by determination of changes in elongation at break. The results showed that for all steel materials the uniform corrosion was very low in all positions. The corrosion rate was between 0.2 and 0.4 {mu}m/year, which suggests that they would perform well from a uniform corrosion resistance point of view. The only clear difference among the steels was that the weld of SAF2507 showed a higher frequency of pits than that in the weld of the other steels. It however ought to be pointed out that the metallic materials that were exposed in the inlet of the condenser, were not exposed in the probably most aggressive region, the so called wet-dry zone. If so, a difference regarding the degree of corrosion attack on the different materials might would have been the case. The results related to polymeric materials showed among other things that the new glass-fibre type, Arcotex, is not suitable to be used for laminates in the environments studied, because of a too low osmosis resistance which gave rise to damage in the form of microdelaminations and blistering. The new resin Atlac E-Nova FW 1045 showed a markedly less corrosion resistance to hot flue gases compared to the conventional ones based on Atlac 590 and Derakane 470. Compared to surface veil reinforcement made of glass and carbon fibre, the use of a woven fabric of carbon fibre in the surface layer seemed to generally improve the resistance of the laminate to the studied environments with respect to the retention of the mechanical properties. The glass-flake materials showed good
Fermion condensation and gapped domain walls in topological orders
Energy Technology Data Exchange (ETDEWEB)
Wan, Yidun [Department of Physics and Center for Field Theory and Particle Physics, Fudan University,Shanghai 200433 (China); Collaborative Innovation Center of Advanced Microstructures, Nanjing University,Nanjing 210093 (China); Perimeter Institute for Theoretical Physics,Waterloo N2L 2Y5, Ontario (Canada); Wang, Chenjie [Perimeter Institute for Theoretical Physics,Waterloo N2L 2Y5, Ontario (Canada)
2017-03-31
We study fermion condensation in bosonic topological orders in two spatial dimensions. Fermion condensation may be realized as gapped domain walls between bosonic and fermionic topological orders, which may be thought of as real-space phase transitions from bosonic to fermionic topological orders. This picture generalizes the previous idea of understanding boson condensation as gapped domain walls between bosonic topological orders. While simple-current fermion condensation was considered before, we systematically study general fermion condensation and show that it obeys a Hierarchy Principle: a general fermion condensation can always be decomposed into a boson condensation followed by a minimal fermion condensation. The latter involves only a single self-fermion that is its own anti-particle and that has unit quantum dimension. We develop the rules of minimal fermion condensation, which together with the known rules of boson condensation, provides a full set of rules for general fermion condensation.
UPTF-TRAM experiments for SBLOCA: Evaluation of condensation processes in TRAM tests A6 and A7
Energy Technology Data Exchange (ETDEWEB)
Sonneburg, H.G.; Tuunanen, J.; Palazov, V.V. [Gesellschaft fuer Anlagen-und Reaktorsicherheit (GRS), Muenchen (Germany)
1995-09-01
The investigation of thermal-hydraulic phenomena related to reactor transients with accident management measures is the goal of the TRansient and accident Management (TRAM) experimental programme being carried out at the Upper Plenum Test Facility (UPTF) at Mannheim (Germany). These experimental investigations and test analyses are funded by the German Federal Minister for Research and Technology (BMFT). The UPTF simulates these phenomena in a 1:1 such relative to the dimension of a PWR. Condensation of steam during Emergency Core Cooling (ECC) water injection from accumulators into the primary system is one of the phenomena studied within the accumulators into the primary system is one of the phenomena studied within the TRAM programme. This phenomenon partly controls the efficiency of accumulator injection if the high pressure safety systems fail. Beside this, the condensation within the nitrogen inside the accumulator for a certain period controls the pressure development inside the accumulator. Thus, both condensation phenomena determine the ECC flow rate delivered to the primary system. Concerning the condensation inside the primary system, this is also of safety relevance in the case of Pressurized Thermal Shock (PTS) during cold leg injection.
Heat transfer degradation during condensation of non-azeotropic mixtures
Azzolin, M.; Berto, A.; Bortolin, S.; Del, D., Col
2017-11-01
International organizations call for a reduction of the HFCs production and utilizations in the next years. Binary or ternary blends of hydroflourocarbons (HFCs) and hydrofluoroolefins (HFOs) are emerging as possible substitutes for high Global Warming Potential (GWP) fluids currently employed in some refrigeration and air-conditioning applications. In some cases, these mixtures are non-azeotropic and thus, during phase-change at constant pressure, they present a temperature glide that, for some blends, can be higher than 10 K. Such temperature variation during phase change could lead to a better matching between the refrigerant and the water temperature profiles in a condenser, thus reducing the exergy losses associated with the heat transfer process. Nevertheless, the additional mass transfer resistance which occurs during the phase change of zeotropic mixtures leads to a heat transfer degradation. Therefore, the design of a condenser working with a zeotropic mixture poses the problem of how to extend the correlations developed for pure fluids to the case of condensation of mixtures. Experimental data taken are very helpful in the assessment of design procedures. In the present paper, heat transfer coefficients have been measured during condensation of zeotropic mixtures of HFC and HFO fluids. Tests have been carried out in the test rig available at the Two Phase Heat Transfer Lab of University of Padova. During the condensation tests, the heat is subtracted from the mixture by using cold water and the heat transfer coefficient is obtained from the measurement of the heat flux on the water side, the direct measurements of the wall temperature and saturation temperature. Tests have been performed at 40°C mean saturation temperature. The present experimental database is used to assess predictive correlations for condensation of mixtures, providing valuable information on the applicability of available models.
High-efficiency condenser of steam from a steam-gas mixture
Milman, O. O.; Krylov, V. S.; Ptakhin, A. V.; Kondratev, A. V.; Yankov, G. G.
2017-12-01
The design of a module for a high-efficiency condenser of steam with a high content (up to 15%) of noncondensable gases (NCGs) with a nearly constant steam-gas mixture (SGM) velocity during the condensation of steam has been developed. This module provides the possibility to estimate the operational efficiency of six condenser zones during the motion of steam from the inlet to the SGM suction point. Some results of the experimental tests of the pilot high-efficiency condenser module are presented. The dependence of the average heat transfer coefficient k¯ on the volumetric NCG concentration v¯ has been derived. It is shown that the high-efficiency condenser module can provide a moderate decrease in k¯ from 4400-4600 to 2600-2800 W/(m2 K) at v¯ ≈ 0.5-9.0%. The heat transfer coefficient distribution over different module zones at a heat duty close to its nominal value has been obtained. From this distribution, it can be seen that the average heat transfer coefficient decreases to 2600 W/(m2 K) at an NCG concentration v¯ = 7.5%, but the first condenser sections ( 1- 3) retain high values of k¯ at a level of no lower than 3200 W/(m2 K), and the last sections operate less well, having k¯ at a level of 1700 W/(m2 K). The dependence of the average heat transfer coefficient on the water velocity in condenser tubes has been obtained at a nearly nominal duty such that the extrapolation of this dependence to the water velocity of 2 m/s may be expected to give k¯ = 5000 W/(m2 K) for relatively pure steam, but an increase in k¯ at v¯ = 8% will be smaller. The effect of the gas removal device characteristic on the operation of the high-efficiency condenser module is described. The design developed for the steam condenser of a gas-turbine plant with a power of 25 MW, a steam flow rate of 40.2 t/h, and a CO2 concentration of up to 12% with consideration for the results of performed studies is presented.
Modelling of Condensation in Vertical Tubes for Passive Safety System
International Nuclear Information System (INIS)
Papini, D.; Ricotti, M.; Santini, L.; Grgic, D.
2008-01-01
Condensation in vertical tubes plays an important role in the performance of heat exchangers in passive safety systems, widely adopted in next generation reactors. Vertical pipe condensers are implemented in the GE-SBWR1000 Isolation Condenser as well as in the Emergency Heat Removal System (EHRS) of the IRIS reactor. The transient and safety analysis is usually carried out by means of best-estimate, thermalhydraulic codes, as RELAP. Suitable heat transfer correlations are required to duly model the two-phase processes. As far as the condensation process is concerned, RELAP5/MOD3.3 adopts the Nusselt correlation to calculate the heat transfer coefficient in laminar conditions and the Shah correlation for turbulent conditions; the maximum of the predictions from laminar and turbulent regimes is used to calculate the condensation heat transfer coefficient. Shah correlation is generally considered as the best empirical correlation for turbulent annular film condensation, but suitable in proper ranges of the various parameters. Nevertheless, recent investigations have pointed out that its validity is highly questionable for high pressure and large diameter tube applications with water, as should be for the utilization for vertical tube condensers in passive safety systems. Thus, a best-estimate model, based on the theory of film condensation on a plain wall, is proposed. Condensate velocity, expressed in terms of Reynolds number, governs the development of three different regime zones: laminar, laminar wavy and turbulent. The best correlation for each regime (Nusselt's for laminar, Kutateladze's for laminar wavy and Chen's for turbulent) is considered and then implemented in RELAP code. Comparison between the Nusselt-Shah and the proposed model shows substantial differences in heat transfer coefficient prediction. Especially, a trend of increasing value of the heat transfer coefficient with tube abscissa (and quality decreasing) is predicted, when turbulence
Models of coherent exciton condensation
International Nuclear Information System (INIS)
Littlewood, P B; Eastham, P R; Keeling, J M J; Marchetti, F M; Simons, B D; Szymanska, M H
2004-01-01
That excitons in solids might condense into a phase-coherent ground state was proposed about 40 years ago, and has been attracting experimental and theoretical attention ever since. Although experimental confirmation has been hard to come by, the concepts released by this phenomenon have been widely influential. This tutorial review discusses general aspects of the theory of exciton and polariton condensates, focusing on the reasons for coherence in the ground state wavefunction, the BCS to Bose crossover(s) for excitons and for polaritons, and the relationship of the coherent condensates to standard lasers
Models of coherent exciton condensation
Energy Technology Data Exchange (ETDEWEB)
Littlewood, P B [Theory of Condensed Matter, Cavendish Laboratory, Cambridge CB3 0HE (United Kingdom); Eastham, P R [Theory of Condensed Matter, Cavendish Laboratory, Cambridge CB3 0HE (United Kingdom); Keeling, J M J [Theory of Condensed Matter, Cavendish Laboratory, Cambridge CB3 0HE (United Kingdom); Marchetti, F M [Theory of Condensed Matter, Cavendish Laboratory, Cambridge CB3 0HE (United Kingdom); Simons, B D [Theory of Condensed Matter, Cavendish Laboratory, Cambridge CB3 0HE (United Kingdom); Szymanska, M H [Theory of Condensed Matter, Cavendish Laboratory, Cambridge CB3 0HE (United Kingdom)
2004-09-08
That excitons in solids might condense into a phase-coherent ground state was proposed about 40 years ago, and has been attracting experimental and theoretical attention ever since. Although experimental confirmation has been hard to come by, the concepts released by this phenomenon have been widely influential. This tutorial review discusses general aspects of the theory of exciton and polariton condensates, focusing on the reasons for coherence in the ground state wavefunction, the BCS to Bose crossover(s) for excitons and for polaritons, and the relationship of the coherent condensates to standard lasers.
Dynamic Modeling of Steam Condenser and Design of PI Controller Based on Grey Wolf Optimizer
Shu-Xia Li; Jie-Sheng Wang
2015-01-01
Shell-and-tube condenser is a heat exchanger for cooling steam with high temperature and pressure, which is one of the main kinds of heat exchange equipment in thermal, nuclear, and marine power plant. Based on the lumped parameter modeling method, the dynamic mathematical model of the simplified steam condenser is established. Then, the pressure PI control system of steam condenser based on the Matlab/Simulink simulation platform is designed. In order to obtain better performance, a new meta...
Field, Robert; Kim, Daehyun; Kelley, Max; LeGrande, Allegra; Worden, John; Schmidt, Gavin
2014-05-01
Observational and theoretical arguments suggest that satellite retrievals of the stable isotope composition of water vapor could be useful for climate model evaluation. The isotopic composition of water vapor is controlled by the same processes that control water vapor amount, but the observed distribution of isotopic composition is distinct from amount itself . This is due to the fractionation that occurs between the abundant H216O isotopes (isotopologues) and the rare and heavy H218O and HDO isotopes during evaporation and condensation. The fractionation physics are much simpler than the underlying moist physics; discrepancies between observed and modeled isotopic fields are more likely due to problems in the latter. Isotopic measurements therefore have the potential for identifying problems that might not be apparent from more conventional measurements. Isotopic tracers have existed in climate models since the 1980s but it is only since the mid 2000s that there have been enough data for meaningful model evaluation in this sense, in the troposphere at least. We have evaluated the NASA GISS ModelE2 general circulation model over the tropics against water isotope (HDO/H2O) retrievals from the Aura Tropospheric Emission Spectrometer (TES), alongside more conventional measurements. A small ensemble of experiments was performed with physics perturbations to the cumulus and planetary boundary layer schemes, done in the context of the normal model development process. We examined the degree to which model-data agreement could be used to constrain a select group of internal processes in the model, namely condensate evaporation, entrainment strength, and moist convective air mass flux. All are difficult to parameterize, but exert strong influence over model performance. We found that the water isotope composition was significantly more sensitive to physics changes than precipitation, temperature or relative humidity through the depth of the tropical troposphere. Among the
International Nuclear Information System (INIS)
Kabeel, A.E.; Omara, Z.M.; Essa, F.A.
2014-01-01
Highlights: • The effect of using nanofluids on the solar still performance is investigated. • The solar still with external condenser increases the productivity by about 53.2%. • Using nanofluids improves the solar still water productivity by about 116%. - Abstract: The distilled water productivity of the single basin solar still is very limited. In this context, the design modification of a single basin solar still has been investigated to improve the solar still performance through increasing the productivity of distilled water. The experimental attempts are made to enhance the solar still productivity by using nanofluids and also by integrating the still basin with external condenser. The used nanofluid is the suspended nanosized solid particles of aluminum-oxide in water. Nanofluids change the transport properties, heat transfer characteristics and evaporative properties of the water. Nanofluids are expected to exhibit superior evaporation rate compared with conventional water. The effect of adding external condenser to the still basin is to decrease the heat loss by convection from water to glass as the condenser acts as an additional and effective heat and mass sink. So, the effect of drawn vapor at different speeds was investigated. The results show that integrating the solar still with external condenser increases the distillate water yield by about 53.2%. And using nanofluids improves the solar still water productivity by about 116%, when the still integrated with the external condenser
International Nuclear Information System (INIS)
Ibrahim, Oussama; Fardoun, Farouk; Younes, Rafic; Louahlia-Gualous, Hasna
2014-01-01
This paper presents a dynamic simulation model to predict the performance of an ASHPWH (air source heat pump water heater). The developed model is used to assess its performance in the Lebanese context. It is shown that for the four Lebanese climatic zones, the expected monthly values of the average COP (coefficient of performance) varies from 2.9 to 5, leading to high efficiencies compared with conventional electric water heaters. The energy savings and GHG (greenhouse gas) emissions reduction are investigated for each zone. Furthermore, it is recommended to use the ASHPWH during the period of highest daily ambient temperatures (noon or afternoon), assuming that the electricity tariff and hot water loads are constant. In addition, an optimal management model for the ASHPWH is developed and applied for a typical winter day of Beirut. Moreover, the developed dynamic model of ASHPWH is used to compare the performance of three similar systems that differ only with the condenser geometry, where results show that using mini-condenser geometries increase the COP (coefficient of performance) and consequently, more energy is saved as well as more GHG emissions are reduced. In addition, the condenser “surface compactness” is increased giving rise to an efficient compact heat exchanger. - Highlights: • Numerical modeling and experimental validation for ASHPWH (air source heat pump water heater). • Optimization of the ASHPWH-condenser length. • Comparison of the ASHPWH with conventional electric water heater according to energy efficiency and green gas house emissions. • Development of an energetic-economic optimal management model for ASHPWH. • Energetic and environmental assessment of ASHPWH with mini-tubes condensers
Quality factors to consider in condensate selection
Energy Technology Data Exchange (ETDEWEB)
Lywood, B. [Crude Quality Inc., Edmonton, AB (Canada)
2009-07-01
Many factors must be considered when assessing the feasibility of using condensates as a diluent for bitumen or heavy crude production blending. In addition to commercial issues, the effect of condensate quality is a key consideration. In general, condensate quality refers to density and viscosity. However, valuation decisions could be enhanced through the expansion of quality definitions and understanding. This presentation focused on the parameters that are important in choosing a diluent grade product. It also reviewed pipeline and industry specifications and provided additional information regarding general properties for bitumen and condensate compatibility; sampling and quality testing needs; and existing sources of information regarding condensate quality. tabs., figs.
Advances in modelling of condensation phenomena
Energy Technology Data Exchange (ETDEWEB)
Liu, W.S.; Zaltsgendler, E. [Ontario Hydro Nuclear, Toronto (Canada); Hanna, B. [Atomic Energy of Canada Limited, Pinawa, Manitoba (Canada)
1997-07-01
The physical parameters in the modelling of condensation phenomena in the CANDU reactor system codes are discussed. The experimental programs used for thermal-hydraulic code validation in the Canadian nuclear industry are briefly described. The modelling of vapour generation and in particular condensation plays a key role in modelling of postulated reactor transients. The condensation models adopted in the current state-of-the-art two-fluid CANDU reactor thermal-hydraulic system codes (CATHENA and TUF) are described. As examples of the modelling challenges faced, the simulation of a cold water injection experiment by CATHENA and the simulation of a condensation induced water hammer experiment by TUF are described.
Advances in modelling of condensation phenomena
International Nuclear Information System (INIS)
Liu, W.S.; Zaltsgendler, E.; Hanna, B.
1997-01-01
The physical parameters in the modelling of condensation phenomena in the CANDU reactor system codes are discussed. The experimental programs used for thermal-hydraulic code validation in the Canadian nuclear industry are briefly described. The modelling of vapour generation and in particular condensation plays a key role in modelling of postulated reactor transients. The condensation models adopted in the current state-of-the-art two-fluid CANDU reactor thermal-hydraulic system codes (CATHENA and TUF) are described. As examples of the modelling challenges faced, the simulation of a cold water injection experiment by CATHENA and the simulation of a condensation induced water hammer experiment by TUF are described
International Nuclear Information System (INIS)
Grooten, M.H.M.; Van der Geld, C.W.M.
2012-01-01
In this study, the effect of a partially structured Ti-coated plate surface on droplet drainage and heat transfer in dropwise condensation in a compact plate heat exchanger is investigated. In the presence of high concentrations of inert gases, heat transfer is governed by vapor diffusion and condensate drainage is of major importance. A structured coating of the condenser plates is applied to create two coexisting dropwise condensation patterns. The structured Ti-coating constrains drainage and introduces directed surface energy 'gradients', 1-D binary patterns. The condenser with the partially structured coating is compared with two equally sized condensers: a full PVDF and a fully Ti-coated PVDF condenser. It is found that drop drainage is promoted by oriented Ti-coated tracks with a width of approximately the diameter of the maximum drop size to such a degree that the heat transfer performance is practically the same as that of a fully Ti-coated exchanger. Design recommendations are given. (authors)
Condensation on Superhydrophobic Copper Oxide Nanostructures
Enright, Ryan; Miljkovic, Nenad; Dou, Nicholas; Nam, Youngsuk; Wang, Evelyn N.
2013-01-01
Condensation is an important process in both emerging and traditional power generation and water desalination technologies. Superhydrophobic nanostructures promise enhanced condensation heat transfer by reducing the characteristic size of departing droplets via a surface-tension-driven mechanism [1]. In this work, we investigated a scalable synthesis technique to produce oxide nanostructures on copper surfaces capable of sustaining superhydrophobic condensation and characterized the growth an...
Molecular equilibrium with condensation
International Nuclear Information System (INIS)
Sharp, C.M.; Huebner, W.F.
1990-01-01
Minimization of the Gibbs energy of formation for species of chemical elements and compounds in their gas and condensed phases determines their relative abundances in a mixture in chemical equilibrium. The procedure is more general and more powerful than previous abundance determinations in multiphase astrophysical mixtures. Some results for astrophysical equations of state are presented, and the effects of condensation on opacity are briefly indicated. 18 refs
Nonlocal Quantum Effects with Bose-Einstein Condensates
International Nuclear Information System (INIS)
Laloee, F.; Mullin, W. J.
2007-01-01
We study theoretically the properties of two Bose-Einstein condensates in different spin states, represented by a double Fock state. Individual measurements of the spins of the particles are performed in transverse directions, giving access to the relative phase of the condensates. Initially, this phase is completely undefined, and the first measurements provide random results. But a fixed value of this phase rapidly emerges under the effect of the successive quantum measurements, giving rise to a quasiclassical situation where all spins have parallel transverse orientations. If the number of measurements reaches its maximum (the number of particles), quantum effects show up again, giving rise to violations of Bell type inequalities. The violation of Bell-Clauser-Horne-Shimony-Holt inequalities with an arbitrarily large number of spins may be comparable (or even equal) to that obtained with two spins
Evaluation of non-condensable gas effect during LBLOCA in an OPR1000 Plant
Energy Technology Data Exchange (ETDEWEB)
Yoo, Seung Hun; Seul, Kwang-Won; Bang, Young-Seok; Lee, Jun Soo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)
2015-05-15
Gas accumulation in the nuclear power plant may cause diverse safety issues such as water hammer, pump cavitation and inadvertent valve actuation. The Nuclear Regulatory Commission (NRC) has published twenty Information Notices, two Generic Letters, and one NUREG report related to the issue of the gas accumulation. It has been considered that gas accumulation occurred since the beginning of commercial nuclear power plant operation and may occur in the currently operating plants. Gas accumulation in the Emergency Core Cooling System (ECCS) is the condition that did not consider in Accident Analysis of Final Safety Analysis Report or Technical Specification and may finally result in degradation or loss of the safety functions. In this paper, the effect of gas accumulation in the ECCS has been analyzed by modeling non-condensable gas injection during the operation of Safety Injection Tank (SIT) and Low Pressure Safety Injection (LPSI) under the LBLOCA condition. Gas accumulation in the ECCS has been dealt with one of significant safety issues in the operating nuclear power plants. In order to identify the effect of the non-condensable gas in Hanul unit 3 and 4, the sensitivity studies for gas quantity, location or injection time was conducted for high or low pressure condition. At high pressure condition, the injected gas induced the reduced SIT flow rate and the reduced period of SIT injection. The reflood PCT at 5 ft''3 condition was 1150 K which was 49K higher than that at no gas condition. At low pressure condition, the reduced flow rate and the increased reflood PCT were also identified. However, the PCT deviation due to different gas quantity was not large as much as that at high pressure condition. We concluded that it is necessary to evaluate the effect of the accumulated gas with the consideration of plant- specific conditions such as system pressure, accumulated location, gas quantity and injection time.
Allocation of synchronous condensers for restoration of system short-circuit power
DEFF Research Database (Denmark)
Marrazi, Emanuel; Yang, Guangya; Weinreich-Jensen, Peter
2017-01-01
Modern power systems, employing an increasing number of converter-based renewable energy sources (RES) and decreasing the usage of conventional power plants, are leading to lower levels of short-circuit power and rotational inertia. A solution to this is the employment of synchronous condensers...... in the grid, in order to provide sufficient short-circuit power. This results in the increase of the short-circuit ratio (SCR) at transmission system bus-bars serving as points of interconnection (POI) to renewable generation. Evaluation of the required capacity and grid-location of the synchronous condensers......, isinherently a mixed integer non-linear optimization problem, which could not be done on manual basis considering each type of machine and all bus-bars. This study therefore proposes a method of optimal allocation of synchronous condensers in a hypothetic future scenario of a transmission system fed...
The Effect of Condensing Steam Turbine Exhaust Hood Body Geometry on Exhaust Performance Efficiency
Gribin, V. G.; Paramonov, A. N.; Mitrokhova, O. M.
2018-06-01
The article presents data from combined numerical and experimental investigations of the effect that the overall dimensions of the exhaust hood of a steam turbine with an underslung condenser has on the aerodynamic losses in the hood. Owing to the properly selected minimum permissible overall dimensions of the exhaust hood, more efficient operation of this turbine component is achieved, better vibration stability of the turbine set shaft line is obtained, and lower costs are required for arranging the steam turbine plant in the turbine building. Experiments have shown that the main overall dimensions of the hood body have a determining effect on the exhaust hood flow path profile and on its aerodynamic performance. Owing to properly selected ratios between the exhaust hood body main sizes without a diffuser, a total loss coefficient equal to approximately unity has been obtained. By using an axial-radial diffuser, the energy loss can be decreased by 30-40% depending on the geometrical parameters and level of velocities in the inlet section of a hood having the optimal overall dimensions. By using the obtained results, it becomes possible to evaluate the overall dimensions necessary for achieving the maximal aerodynamic hood efficiency and, as a consequence, to obtain better technical and economic indicators of the turbine plant as a whole already at the initial stage of its designing. If a need arises to select overall dimensions smaller than their optimal values, the increase of energy loss can be estimated using the presented dependences. The cycle of investigations was carried out on the experimental setups available in the fundamental research laboratory of the Moscow Power Engineering Institute National University's Department of Steam and Gas Turbines with due regard to the operating parameters and similarity criteria.
Continuous condensation in nanogrooves
Malijevský, Alexandr
2018-05-01
We consider condensation in a capillary groove of width L and depth D , formed by walls that are completely wet (contact angle θ =0 ), which is in a contact with a gas reservoir of the chemical potential μ . On a mesoscopic level, the condensation process can be described in terms of the midpoint height ℓ of a meniscus formed at the liquid-gas interface. For macroscopically deep grooves (D →∞ ), and in the presence of long-range (dispersion) forces, the condensation corresponds to a second-order phase transition, such that ℓ ˜(μcc-μ ) -1 /4 as μ →μcc - where μc c is the chemical potential pertinent to capillary condensation in a slit pore of width L . For finite values of D , the transition becomes rounded and the groove becomes filled with liquid at a chemical potential higher than μc c with a difference of the order of D-3. For sufficiently deep grooves, the meniscus growth initially follows the power law ℓ ˜(μcc-μ ) -1 /4 , but this behavior eventually crosses over to ℓ ˜D -(μ-μc c) -1 /3 above μc c, with a gap between the two regimes shown to be δ ¯μ ˜D-3 . Right at μ =μc c , when the groove is only partially filled with liquid, the height of the meniscus scales as ℓ*˜(D3L) 1 /4 . Moreover, the chemical potential (or pressure) at which the groove is half-filled with liquid exhibits a nonmonotonic dependence on D with a maximum at D ≈3 L /2 and coincides with μc c when L ≈D . Finally, we show that condensation in finite grooves can be mapped on the condensation in capillary slits formed by two asymmetric (competing) walls a distance D apart with potential strengths depending on L . All these predictions, based on mesoscopic arguments, are confirmed by fully microscopic Rosenfeld's density functional theory with a reasonable agreement down to surprisingly small values of both L and D .
MELCOR 1.8.1 assessment: PNL Ice Condenser Aerosol Experiments
International Nuclear Information System (INIS)
Gross, R.J.
1993-06-01
The MELCOR code was used to simulate PNL's Ice Condenser Experiments 11-6 and 16-11. In these experiments, ZnS was injected into a mixing chamber, and the combined steam/air/aerosol mixture flowed into an ice condenser which was l4.7m tall. Experiment 11-6 was a low flow test; Experiment l6-1l was a high flow test. Temperatures in the ice condenser region and particle retention were measured in these tests. MELCOR predictions compared very well to the experimental data. The MELCOR calculations were also compared to CONTAIN code calculations for the same tests. A number of sensitivity studies were performed. It as found that simulation time step, aerosol parameters such as the number of MAEROS components and sections used and the particle density, and ice condenser parameters such as the energy capacity of the ice, ice heat transfer coefficient multiplier, and ice heat structure characteristic length all could affect the results. Thermal/hydraulic parameters such as control volume equilibrium assumptions, flow loss coefficients, and the bubble rise model were found to affect the results less significantly. MELCOR results were not machine dependent for this problem
Condensed Tannins from Longan Bark as Inhibitor of Tyrosinase: Structure, Activity, and Mechanism.
Chai, Wei-Ming; Huang, Qian; Lin, Mei-Zhen; Ou-Yang, Chong; Huang, Wen-Yang; Wang, Ying-Xia; Xu, Kai-Li; Feng, Hui-Ling
2018-01-31
In this study, the content, structure, antityrosinase activity, and mechanism of longan bark condensed tannins were evaluated. The findings obtained from mass spectrometry demonstrated that longan bark condensed tannins were mixtures of procyanidins, propelargonidins, prodelphinidins, and their acyl derivatives (galloyl and p-hydroxybenzoate). The enzyme analysis indicated that these mixtures were efficient, reversible, and mixed (competitive is dominant) inhibitor of tyrosinase. What's more, the mixtures showed good inhibitions on proliferation, intracellular enzyme activity and melanogenesis of mouse melanoma cells (B 16 ). From molecular docking, the results showed the interactions between inhibitors and tyrosinase were driven by hydrogen bond, electrostatic, and hydrophobic interactions. In addition, high levels of total phenolic and extractable condensed tannins suggested that longan bark might be a good source of tyrosinase inhibitor. This study would offer theoretical basis for the development of longan bark condensed tannins as novel food preservatives and medicines of skin diseases.
Direct contact condensation in packed beds
Energy Technology Data Exchange (ETDEWEB)
Li, Yi; Klausner, James F.; Mei, Renwei; Knight, Jessica [Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611 (United States)
2006-12-15
A diffusion driven desalination process was recently described where a very effective direct contact condenser with a packed bed is used to condense water vapor out of an air/vapor mixture. A laboratory scale direct contact condenser has been fabricated as a twin tower structure with two stages, co-current and countercurrent. Experiments have been operated in each stage with respective saturated air inlet temperatures of 36, 40 and 43{sup o}C. The temperature and humidity data have been collected at the inlet and exit of the packed bed for different water to air mass flow ratios that vary between 0 and 2.5. A one-dimensional model based on conservation principles has been developed, which predicts the variation of temperature, humidity, and condensation rate through the condenser stages. Agreement between the model and experiments is very good. It is observed that the countercurrent flow stage condensation effectiveness is significantly higher than that for the co-current stage. The condensation heat and mass transfer rates were found to decrease when water blockages occur within the packed bed. Using high-speed digital cinematography, it was observed that this problem can occur at any operating condition, and is dependent on the packing surface wetting characteristics. This observation is used to explain the requirement for two different empirical constants, depending on packing diameter, suggested by Onda for the air side mass transfer coefficient correlation. (author)
Directory of Open Access Journals (Sweden)
Janis IEJAVS
2016-09-01
Full Text Available Invention of light weight cellular wood material (CWM with a trade mark of Dendrolight is one of innovations in wood industry of the last decade. The aim of the research was to define the water vapour permeability properties of CWM and to analyse the condensation risk of various wall envelopes where solid wood cellular material is used. To determine the water vapour permeability of CWM, test samples were produced in the factory using routine production technology and tested according to the standard EN 12086:2014. Water vapour permeability factor (μ and other properties of six different configurations of CWM samples were determined. Using the experimental data the indicative influence of geometrical parameters such as lamella thickness, number of lamellas and material direction were investigated and evaluated. To study the condensation risk within the wall envelope containing CWM calculation method given in LVS EN ISO 13788:2012 was used. To ease the calculation process previously developed JavaScript calculation software that had only capability to calculate thermal transmittance was extended so that condensation risk in multi-layer composite walls can be analysed. Water vapour permeability factor in CWM is highly direction dependant. If parallel and perpendicular direction of CWM is compared the value of water vapour permeability factor can differentiate more than two times. Another significant factor for condensation risk analysis is overall thickness of CWM since it directly influences the equivalent air layer thickness. The influence of other factors such as lamella thickness, or groove depth is minor when water vapour permeability properties are compared. From the analysis of CWM performance in building envelope it can be concluded that uninsulated CWM panels used during winter months will pose the risk of condensation damage to structure, but the risk can be reduced or prevented if insulation layer is applied to the CWM panel wall
Energy Technology Data Exchange (ETDEWEB)
Freis, Daniel; Nachtrodt, Frederik; Sporn, Michael; Tietsch, Wolfgang; Sassen, Felix [Westinghouse Electric Germany GmbH, Mannheim (Germany)
2012-11-01
Westinghouse Electric Germany GmbH has developed a concept for passive cooling of condensate chambers of BWR-type reactors. Due to its compactness the system is feasible as retrofitting measure. The passive condensate chamber cooling system is based on a cooling module with ascending and down pipe that are connected with the evaporation condenser to form a cooling circuit. Based on the consequent use of high-effective heat transport mechanisms, as boiling, condensation without non-condensable gases and mass transport a high cooling performance and compact construction is possible. The system is completely passive and completely diverse to existing active cooling systems. In the frame of a true-scale experiment the significant cooling performance was demonstrated. RELAP5 calculations confirmed the functionality of the cooling module.
Riipinen, I.; Pierce, J. R.; Yli-Juuti, T.; Nieminen, T.; Häkkinen, S.; Ehn, M.; Junninen, H.; Lehtipalo, K.; Petäjä, T.; Slowik, J.; Chang, R.; Shantz, N. C.; Abbatt, J.; Leaitch, W. R.; Kerminen, V.-M.; Worsnop, D. R.; Pandis, S. N.; Donahue, N. M.; Kulmala, M.
2011-04-01
Atmospheric aerosol particles influence global climate as well as impair air quality through their effects on atmospheric visibility and human health. Ultrafine (<100 nm) particles often dominate aerosol numbers, and nucleation of atmospheric vapors is an important source of these particles. To have climatic relevance, however, the freshly nucleated particles need to grow in size. We combine observations from two continental sites (Egbert, Canada and Hyytiälä, Finland) to show that condensation of organic vapors is a crucial factor governing the lifetimes and climatic importance of the smallest atmospheric particles. We model the observed ultrafine aerosol growth with a simplified scheme approximating the condensing species as a mixture of effectively non-volatile and semi-volatile species, demonstrate that state-of-the-art organic gas-particle partitioning models fail to reproduce the observations, and propose a modeling approach that is consistent with the measurements. We find that roughly half of the mass of the condensing mass needs to be distributed proportional to the aerosol surface area (thus implying that the condensation is governed by gas-phase concentration rather than the equilibrium vapour pressure) to explain the observed aerosol growth. We demonstrate the large sensitivity of predicted number concentrations of cloud condensation nuclei (CCN) to these interactions between organic vapors and the smallest atmospheric nanoparticles - highlighting the need for representing this process in global climate models.
Directory of Open Access Journals (Sweden)
Xiao-Xin Chen
Full Text Available Condensed tannins from Ficus virens leaves, fruit, and stem bark were isolated and their structures characterized by 13C nuclear magnetic resonance spectrometry, high performance liquid chromatography electrospray ionization mass spectrometry, and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. The results showed that the leaves, fruit, and stem bark condensed tannins were complex mixtures of homo- and heteropolymers of B-type procyanidins and prodelphinidins with degrees of polymerization up to hexamer, dodecamer, and pentadecamer, respectively. Antityrosinase activities of the condensed tannins were studied. The results indicated that the condensed tannins were potent tyrosinase inhibitors. The concentrations for the leaves, fruit, and stem bark condensed tannins leading to 50% enzyme activity were determined to be 131.67, 99.89, and 106.22 μg/ml on monophenolase activity, and 128.42, 43.07, and 74.27 μg/ml on diphenolase activity. The inhibition mechanism, type, and constants of the condensed tannins on the diphenolase activity were further investigated. The results indicated that the condensed tannins were reversible and mixed type inhibitors. Fluorescence quenching, copper interacting, and molecular docking techniques were utilized to unravel the molecular mechanisms of the inhibition. The results showed that the hydroxyl group on the B ring of the condensed tannins could chelate the dicopper irons of the enzyme. Moreover, the condensed tannins could reduce the enzyme product o-quinones into colourless compounds. These results would contribute to the development and design of antityrosinase agents.
Zamuruyev, Konstantin O; Bardaweel, Hamzeh K; Carron, Christopher J; Kenyon, Nicholas J; Brand, Oliver; Delplanque, Jean-Pierre; Davis, Cristina E
2014-08-26
Combination of two physical phenomena, capillary pressure gradient and wettability gradient, allows a simple two-step fabrication process that yields a reliable hydrophobic self-cleaning condenser surface. The surface is fabricated with specific microscopic topography and further treatment with a chemically inert low-surface-energy material. This process does not require growth of nanofeatures (nanotubes) or hydrophilic-hydrophobic patterning of the surface. Trapezoidal geometry of the microfeatures facilitates droplet transfer from the Wenzel to the Cassie state and reduces droplet critical diameter. The geometry of the micropatterns enhances local coalescence and directional movement for droplets with diameter much smaller than the radial length of the micropatterns. The hydrophobic self-cleaning micropatterned condenser surface prevents liquid film formation and promotes continuous dropwise condensation cycle. Upon dropwise condensation, droplets follow a designed wettability gradient created with micropatterns from the most hydrophobic to the least hydrophobic end of the surface. The surface has higher condensation efficiency, due to its directional self-cleaning property, than a plain hydrophobic surface. We explain the self-actuated droplet collection mechanism on the condenser surface and demonstrate experimentally the creation of an effective wettability gradient over a 6 mm radial distance. In spite of its fabrication simplicity, the fabricated surface demonstrates self-cleaning property, enhanced condensation performance, and reliability over time. Our work enables creation of a hydrophobic condenser surface with the directional self-cleaning property that can be used for collection of biological (chemical, environmental) aerosol samples or for condensation enhancement.
Energy Technology Data Exchange (ETDEWEB)
Smith, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
2016-04-14
Ten chemical processing cell (CPC) experiments were performed using simulant to evaluate Sludge Batch 9 for sludge-only and coupled processing using the nitric-formic flowsheet in the Defense Waste Processing Facility (DWPF). Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) cycles were performed on eight of the ten. The other two were SRAT cycles only. Samples of the condensate, sludge, and off gas were taken to monitor the chemistry of the CPC experiments. The Savannah River National Laboratory (SRNL) has previously shown antifoam decomposes to form flammable organic products, (hexamethyldisiloxane (HMDSO), trimethylsilanol (TMS), and propanal), that are present in the vapor phase and condensate of the CPC vessels. To minimize antifoam degradation product formation, a new antifoam addition strategy was implemented at SRNL and DWPF to add antifoam undiluted.
Condensing species from flue gas in Puertollano gasification power plant, Spain
Energy Technology Data Exchange (ETDEWEB)
Oriol Font; Xavier Querol; Felica Plana; Pilar Coca; Silvia Burgos; Francisco Garcia Pena [Institute of Earth Sciences ' Jaume Almera' , Barcelona (Spain). Environmental Geology
2006-10-15
The occurrence and distribution of trace elements (Pb, Zn, As, Ge, Cd, Tl, Bi, Sn, and also Ni, Fe and V) in condensates arising from coal gasification was investigated through the study of samples physically deposited on the gas cooling system from the Puertollano IGCC 335 MW power plant. These highly metal enriched samples are suitable for a comprehensive evaluation of the mode of occurrence of these elements in IGCC fly ash. Pb, Zn, Ge, and Fe sulfides, Ni-Fe arsenides, Ge and V oxides as well as traces of K chloride and Pb, Zn and Fe sulfates were determined as the major bearing phases for these elements. Three condensation zones were differentiated as function of the condensation temperatures and metal content: 1. Pb zone (520-750{sup o}C), characterized by the dominance of galena (70-90% of the main crystalline phases), and by the condensation of pyrrhotite and nickeline. 2. Ge-Zn-Pb zone (520-470{sup o}C), with sphalerite and wurzite being the dominant crystalline phases (over 40%), and Ge compounds, GeS{sub 2} and GeO{sub 2}, reaching 30% of the bulk condensates. 3. Zn zone (300-400{sup o}C), characterized by the dominance of Zn sulfides (over 85% of the main crystalline phases). The results obtained from these highly metalliferous condensates show similar forms of occurrence for the studied elements to those obtained in the bulk Puertollano IGCC fly ash (by using XAFS spectroscopy), where the contents of these elements are much lower. Furthermore, the sequential condensation of sulfides during coal gasification is similar to that from volcanic fumaroles, and may thus promote a better understanding of volcanic deposits. 23 refs., 7 figs., 5 tabs.
Bose-Einstein condensation of light: general theory.
Sob'yanin, Denis Nikolaevich
2013-08-01
A theory of Bose-Einstein condensation of light in a dye-filled optical microcavity is presented. The theory is based on the hierarchical maximum entropy principle and allows one to investigate the fluctuating behavior of the photon gas in the microcavity for all numbers of photons, dye molecules, and excitations at all temperatures, including the whole critical region. The master equation describing the interaction between photons and dye molecules in the microcavity is derived and the equivalence between the hierarchical maximum entropy principle and the master equation approach is shown. The cases of a fixed mean total photon number and a fixed total excitation number are considered, and a much sharper, nonparabolic onset of a macroscopic Bose-Einstein condensation of light in the latter case is demonstrated. The theory does not use the grand canonical approximation, takes into account the photon polarization degeneracy, and exactly describes the microscopic, mesoscopic, and macroscopic Bose-Einstein condensation of light. Under certain conditions, it predicts sub-Poissonian statistics of the photon condensate and the polarized photon condensate, and a universal relation takes place between the degrees of second-order coherence for these condensates. In the macroscopic case, there appear a sharp jump in the degrees of second-order coherence, a sharp jump and kink in the reduced standard deviations of the fluctuating numbers of photons in the polarized and whole condensates, and a sharp peak, a cusp, of the Mandel parameter for the whole condensate in the critical region. The possibility of nonclassical light generation in the microcavity with the photon Bose-Einstein condensate is predicted.
Preliminary Analysis of Rapid Condensation Experiment with MARS-KS Code
Energy Technology Data Exchange (ETDEWEB)
Bae, Jae Ho; Jun, Hwang Yong; Jeong, Hae Yong [Sejong University, Seoul (Korea, Republic of)
2016-05-15
In the present study, the rapid condensation experiment performed in MANOTEA facility is analyzed with the MARS-KS code. It is known that there exists some limitation with a system code to predict this kind of a very active condensation due to direct mixing of cold injection flow and steam. Through the analysis we investigated the applicability of MARS-KS code for the design of various passive safety systems in the future. The configuration of the experimental facility MANOTEA, which has been constructed at the University of Maryland - United States Naval Academy, is described and the modeling approach using the MARS-KS code is also provided. The preliminary result shows that the MARS-KS predicts the general trend of pressure and temperature in the condensing part correctly. However, it is also found that there exist some limitations in the simulation such as an unexpected pressure peak or a sudden temperature change.
BWR Passive Containment Cooling System by condensation-driven natural circulation
International Nuclear Information System (INIS)
Vierow, K.M.; Townsend, H.E.; Fitch, J.R.; Andersen, J.G.M.; Alamgir, M.; Schrock, V.E.
1991-01-01
A method of long-term decay heat removal which is safe, reliable, and passive has been incorporated into the design of the Simplified Boiling Water Reactor (SBWR). The primary functions of the Passive Containment Cooling System (PCCS) are to remove heat and maintain the containment pressure below allowable levels following a LOCA. A key component of the PCCS is the PCC condenser unit (PCC). By natural circulation, a steam-nitrogen mixture flows into the PCC heat exchanger, condensate drains to the reactor pressure vessel (RPV), and noncondensables are vented to the suppression chamber (S/C). This analysis focuses on three significant thermal-hydraulic phenomena which occur in the system. Specifically, steam condensation in the presence of a noncondensable, the PCC noncondensable venting and the natural circulation are discussed. Results of TRACG simulations are presented which show that the PCCS performs its intended functions. (author)
Condensation Enhancement by Surface Porosity: Three-Stage Mechanism.
Yarom, Michal; Marmur, Abraham
2015-08-18
Surface defects, such as pores, cracks, and scratches, are naturally occurring and commonly found on solid surfaces. However, the mechanism by which such imperfections promote condensation has not been fully explored. In the current paper we thermodynamically analyze the ability of surface porosity to enhance condensation on a hydrophilic solid. We show that the presence of a surface-embedded pore brings about three distinct stages of condensation. The first is capillary condensation inside the pore until it is full. This provides an ideal hydrophilic surface for continuing the condensation. As a result, spontaneous condensation and wetting can be achieved at lower vapor pressure than on a smooth surface.
CO2 capture by Condensed Rotational Separation
Benthum, van R.J.; Kemenade, van H.P.; Brouwers, J.J.H.; Golombok, M.
2010-01-01
Condensed Rotational Separation (CRS) technology is a patented method to upgrade gas mixtures. A novel application is thecapture of CO2 from coal-combustion fired power stations: Condensed Contaminant Centrifugal Separation in Coal Combustion(C5sep). CRS involves partial condensation of a gas
Induction of premature chromosome condensation by calyculin A for bio dosimetry
International Nuclear Information System (INIS)
Hosseini, S.; Mozdarani, H.
2004-01-01
Background: Premature chromosome condensation is a method for interphase chromosome analysis in bio dosimetry. This study was performed to verify the usefulness of premature chromosome condensation induced by calyculin A in human peripheral blood lymphocytes for biological dosimetry and possible construction of dose-response curve. Materials and methods: Peripheral blood was obtained from a healthy donor and exposed to various doses(0.25- 4 Gy) of γ-rays. The frequency of simple breaks and dicentrics were scored in G 2/M chromosomes of Giemsa stained cells. Results:Results show that the frequency of simple chromosome breaks appears to increase linearly with dose; while the frequency of dicentrics apparently increases linear-quadratically with the dose. Conclusion: Induction of chromosome condensation by calyculin A is a powerful biodisimetric method, which provides a high number of spreads for analysis. With the use of this method, it is possible to overcome problems related to low mitotic index or cell-cycle alterations in routine metaphase analysis and low fusion rate in conventional Premature chromosome condensation technique
Critical energy barrier for capillary condensation in mesopores: Hysteresis and reversibility
International Nuclear Information System (INIS)
Hiratsuka, Tatsumasa; Tanaka, Hideki; Miyahara, Minoru T.
2016-01-01
Capillary condensation in the regime of developing hysteresis occurs at a vapor pressure, P cond , that is less than that of the vapor-like spinodal. This is because the energy barrier for the vapor-liquid transition from a metastable state at P cond becomes equal to the energy fluctuation of the system; however, a detailed mechanism of the spontaneous transition has not been acquired even through extensive experimental and simulation studies. We therefore construct accurate atomistic silica mesopore models for MCM-41 and perform molecular simulations (gauge cell Monte Carlo and grand canonical Monte Carlo) for argon adsorption on the models at subcritical temperatures. A careful comparison between the simulation and experiment reveals that the energy barrier for the capillary condensation has a critical dimensionless value, W c * = 0.175, which corresponds to the thermal fluctuation of the system and depends neither on the mesopore size nor on the temperature. We show that the critical energy barrier W c * controls the capillary condensation pressure P cond and also determines a boundary between the reversible condensation/evaporation regime and the developing hysteresis regime.
Critical energy barrier for capillary condensation in mesopores: Hysteresis and reversibility
Hiratsuka, Tatsumasa; Tanaka, Hideki; Miyahara, Minoru T.
2016-04-01
Capillary condensation in the regime of developing hysteresis occurs at a vapor pressure, Pcond, that is less than that of the vapor-like spinodal. This is because the energy barrier for the vapor-liquid transition from a metastable state at Pcond becomes equal to the energy fluctuation of the system; however, a detailed mechanism of the spontaneous transition has not been acquired even through extensive experimental and simulation studies. We therefore construct accurate atomistic silica mesopore models for MCM-41 and perform molecular simulations (gauge cell Monte Carlo and grand canonical Monte Carlo) for argon adsorption on the models at subcritical temperatures. A careful comparison between the simulation and experiment reveals that the energy barrier for the capillary condensation has a critical dimensionless value, Wc* = 0.175, which corresponds to the thermal fluctuation of the system and depends neither on the mesopore size nor on the temperature. We show that the critical energy barrier Wc* controls the capillary condensation pressure Pcond and also determines a boundary between the reversible condensation/evaporation regime and the developing hysteresis regime.
Vortex sorter for Bose-Einstein condensates
International Nuclear Information System (INIS)
Whyte, Graeme; Veitch, John; Courtial, Johannes; Oehberg, Patrik
2004-01-01
We have designed interferometers that sort Bose-Einstein condensates into their vortex components. The Bose-Einstein condensates in the two arms of the interferometer are rotated with respect to each other through fixed angles; different vortex components then exit the interferometer in different directions. The method we use to rotate the Bose-Einstein condensates involves asymmetric phase imprinting and is itself new. We have modeled rotation through fixed angles and sorting into vortex components with even and odd values of the topological charge of two-dimensional Bose-Einstein condensates in a number of states (pure or superposition vortex states for different values of the scattering length). Our scheme may have applications for quantum information processing
Condensate treatment and oxygen control in power plants
International Nuclear Information System (INIS)
Sakai, Toshiaki; Iida, Kei; Ohashi, Shinichi.
1997-01-01
In thermal and nuclear power stations, the steam that operated turbines is cooled and condensed with condensers. The condensate is heated again with boilers, nuclear reactors or steam generators, but if corrosion products or impurities are contained in the condensate, corrosion and scale formation occur in boilers and others. The filtration facility and the desalting facility for condensate are installed to remove impurities, but water quality control is different in thermal, BWR and PWR plants, therefore, the treatment facilities corresponding to respective condensates have been adopted. In order to reduce the amount of clud generation, the treatment of injecting a small quantity of oxygen into condensate has been adopted. In thermal power plants, all volatile treatment is carried out, in which corrosion is prevented by the addition of ammonia and hydrazine to boiler feedwater. The condensate filters of various types and the NH 4 type condensate desalter for thermal power plants are described. In BWR power plants, steam is generated in nuclear reactors, therefore, the addition of chemicals into water is never carried out, and high purity neutral water is used. In PWR power plants, the addition of chemicals to water is done in the primary system, and AVT is adopted in the secondary system. Also the condensate treatment facilities are different for both reactors. (K.I.)
Boilers, evaporators, and condensers
International Nuclear Information System (INIS)
Kakac, S.
1991-01-01
This book reports on the boilers, evaporators and condensers that are used in power plants including nuclear power plants. Topics included are forced convection for single-phase side heat exchangers, heat exchanger fouling, industrial heat exchanger design, fossil-fuel-fired boilers, once through boilers, thermodynamic designs of fossil fuel-first boilers, evaporators and condensers in refrigeration and air conditioning systems (with respect to reducing CFC's) and nuclear steam generators
Modeling of Pressure Drop During Refrigerant Condensation in Pipe Minichannels
Sikora, Małgorzata; Bohdal, Tadeusz
2017-12-01
Investigations of refrigerant condensation in pipe minichannels are very challenging and complicated issue. Due to the multitude of influences very important is mathematical and computer modeling. Its allows for performing calculations for many different refrigerants under different flow conditions. A large number of experimental results published in the literature allows for experimental verification of correctness of the models. In this work is presented a mathematical model for calculation of flow resistance during condensation of refrigerants in the pipe minichannel. The model was developed in environment based on conservation equations. The results of calculations were verified by authors own experimental investigations results.
Condensed matter physics in electrochemistry
International Nuclear Information System (INIS)
Kornyshev, A.A.
1991-01-01
Some topics in electrochemistry are considered from the condensed matter physics viewpoint in relation to the problems discussed in this book. Examples of the successful application of condensed matter physics to electrochemistry are discussed together with prospective problems and pressing questions. (author). 127 refs, 4 figs
Competition between Bose-Einstein Condensation and Spin Dynamics.
Naylor, B; Brewczyk, M; Gajda, M; Gorceix, O; Maréchal, E; Vernac, L; Laburthe-Tolra, B
2016-10-28
We study the impact of spin-exchange collisions on the dynamics of Bose-Einstein condensation by rapidly cooling a chromium multicomponent Bose gas. Despite relatively strong spin-dependent interactions, the critical temperature for Bose-Einstein condensation is reached before the spin degrees of freedom fully thermalize. The increase in density due to Bose-Einstein condensation then triggers spin dynamics, hampering the formation of condensates in spin-excited states. Small metastable spinor condensates are, nevertheless, produced, and they manifest in strong spin fluctuations.
21 CFR 886.1380 - Diagnostic condensing lens.
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic condensing lens. 886.1380 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1380 Diagnostic condensing lens. (a) Identification. A diagnostic condensing lens is a device used in binocular indirect ophthalmoscopy (a procedure...
The dynamics of Affleck-Dine condensate collapse
International Nuclear Information System (INIS)
Enqvist, Kari; McDonald, John
2000-01-01
In the MSSM, cosmological scalar field condensates formed along flat directions of the scalar potential (Affleck-Dine condensates) are typically unstable with respect to formation of Q-balls, a type of non-topological soliton. We consider the dynamical evolution of the Affleck-Dine condensate in the MSSM. We discuss the creation and linear growth, in F- and D-term inflation models, of the quantum seed perturbations which in the non-linear regime catalyse the collapse of the condensate to non-topological soliton lumps. We study numerically the evolution of the collapsing condensate lumps and show that the solitons initially formed are not in general Q-balls, but Q-axitons, a pseudo-breather which can have very different properties from Q-balls of the same charge. We calculate the energy and charge radiated from a spherically symmetric condensate lump as it evolves into a Q-axiton. We also discuss the implications for baryogenesis and dark matter
Amplitude oscillations in a non-equilibrium polariton condensate
Brierley, Richard; Littlewood, Peter; Eastham, Paul
2011-03-01
Like cold atomic gases, semiconductor nanostructures provide new opportunities for exploring non-equilibrium quantum dynamics. In semiconductor microcavities the strong coupling between trapped photons and excitons produces new quasiparticles, polaritons, which can undergo Bose-Einstein condensation. Quantum quenches can be realised by rapidly creating cold exciton populations with a laser [Eastham and Phillips, PRB 79 165303 (2009)]. The mean field theory of non-equilibrium polariton condensates predicts oscillations in the condensate amplitude due to the excitation of a Higgs mode. These oscillations are the analogs of those predicted in quenched cold atomic gases and may occur in the polariton system after performing a quench or by direct excitation of the amplitude mode. We have studied the stability of these oscillations beyond mean field theory. We show that homogeneous amplitude oscillations are unstable to decay into lower energy phase modes at finite wavevectors, suggesting the onset of chaotic behaviour. The resulting hierarchy of decay processes can be understood by analogy to optical parametric oscillators in microcavities. Polariton systems thus provide an interesting opportunity to study the dynamics of Higgs-like modes in a solid state system.
Directory of Open Access Journals (Sweden)
Rafał Laskowski
2016-12-01
Full Text Available The diameter and configuration of tubes are important design parameters of power condensers. If a proper tube diameter is applied during the design of a power unit, a high energy efficiency of the condenser itself can be achieved and the performance of the whole power generation unit can be improved. If a tube assembly is to be replaced, one should verify whether the chosen condenser tube diameter is correct. Using a diameter that is too large increases the heat transfer area, leading to over-dimensioning and higher costs of building the condenser. On the other hand, if the diameter is too small, water flows faster through the tubes, which results in larger flow resistance and larger pumping power of the cooling-water pump. Both simple and complex methods can be applied to determine the condenser tube diameter. The paper proposes a method of technical and economic optimisation taking into account the performance of a condenser, the low-pressure (LP part of a turbine, and a cooling-water pump as well as the profit from electric power generation and costs of building the condenser and pumping cooling water. The results obtained by this method were compared with those provided by the following simpler methods: minimization of the entropy generation rate per unit length of a condenser tube (considering entropy generation due to heat transfer and resistance of cooling-water flow, minimization of the total entropy generation rate (considering entropy generation for the system comprising the LP part of the turbine, the condenser, and the cooling-water pump, and maximization of the power unit’s output. The proposed methods were used to verify diameters of tubes in power condensers in a200-MW and a 500-MW power units.
2010-07-01
... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous emission...
Kathman, Steven J; Potts, Ryan J; Ayres, Paul H; Harp, Paul R; Wilson, Cody L; Garner, Charles D
2010-10-01
The mouse dermal assay has long been used to assess the dermal tumorigenicity of cigarette smoke condensate (CSC). This mouse skin model has been developed for use in carcinogenicity testing utilizing the SENCAR mouse as the standard strain. Though the model has limitations, it remains as the most relevant method available to study the dermal tumor promoting potential of mainstream cigarette smoke. In the typical SENCAR mouse CSC bioassay, CSC is applied for 29 weeks following the application of a tumor initiator such as 7,12-dimethylbenz[a]anthracene (DMBA). Several endpoints are considered for analysis including: the percentage of animals with at least one mass, latency, and number of masses per animal. In this paper, a relatively straightforward analytic model and procedure is presented for analyzing the time course of the incidence of masses. The procedure considered here takes advantage of Bayesian statistical techniques, which provide powerful methods for model fitting and simulation. Two datasets are analyzed to illustrate how the model fits the data, how well the model may perform in predicting data from such trials, and how the model may be used as a decision tool when comparing the dermal tumorigenicity of cigarette smoke condensate from multiple cigarette types. The analysis presented here was developed as a statistical decision tool for differentiating between two or more prototype products based on the dermal tumorigenicity. Copyright (c) 2010 Elsevier Inc. All rights reserved.
International Nuclear Information System (INIS)
Tanimoto, K.; Ishii, M.
1998-01-01
Transient characteristics of two-phase natural circulation within a Freon-113 loop with a large condenser have been examined mainly focused on the flashing phenomenon. General behavior was described and parametric studies were performed. The items observed were the period and duration of flashing, peak flow rate, amount of flow carryover per flashing, lowest-peak liquid level within the condenser, and the peak void distribution in the riser section. The parameters considered were the heater power input, valve friction at the heater inlet (simulating the loopwise friction), condenser cooling, degree of subcooling at the heater inlet, and the heat loss to the surroundings. As a whole, the heater power input, valve friction, and the rate of condenser cooling played important roles in flashing while the other effects being marginal. In general, the flow appeared to be more unstable with the larger condensing surface which causes the condensation-induced flashing. (orig.)
Condensed matter analogues of cosmology
Kibble, Tom; Srivastava, Ajit
2013-10-01
liveliest. A number of new experiments are reported here studying the dynamical evolution of domains and defects. Another phenomenon that played a key early role was the formation of vortices in the normal-to-superfluid transition in liquid helium-3. The complicated nature of the order parameter energy surface gives rise to a variety of intriguing effects. This too is still a vigorous field. Superconductivity is a special case because the symmetry that is broken is a gauge symmetry. This is also true in fundamental particle physics theories of relevance to cosmology, and for that reason experiments on superconductors are of particular interest to cosmologists. The situation in this case is more complicated because there are competing mechanisms of defect formation. Experiments in the field have not proved easy, either to perform or to interpret, but the papers in this collection show that good progress has been made of late. In recent years a new type of system has proved immensely fruitful, namely atomic Bose-Einstein or Fermi-gas condensates. Experiments on condensates with tunable parameters have in general provided broad support for the theory, and have also revealed a wide range of interesting and novel features, with intriguing possible analogues in cosmology (e.g. causal horizons and particle creation). The basic idea of the Kibble-Zurek mechanism has been shown to be relevant in this whole range of systems. But numerous complexities have also emerged, concerned for example with the role of inhomogeneity or the existence of composite defects. The field is still developing rapidly. Acknowledgments Finally, we would like to thank all the authors who have contributed to this issue, and the staff of Journal of Physics: Condensed Matter who have made it possible. Condensed matter analogues of cosmology contents Condensed matter analogues of cosmologyTom Kibble and Ajit Srivastava Symmetry breaking in nematic liquid crystals: analogy with cosmology and magnetismR Repnik, A
Exhaled Breath Condensate: Technical and Diagnostic Aspects.
Konstantinidi, Efstathia M; Lappas, Andreas S; Tzortzi, Anna S; Behrakis, Panagiotis K
2015-01-01
The aim of this study was to evaluate the 30-year progress of research on exhaled breath condensate in a disease-based approach. We searched PubMed/Medline, ScienceDirect, and Google Scholar using the following keywords: exhaled breath condensate (EBC), biomarkers, pH, asthma, gastroesophageal reflux (GERD), smoking, COPD, lung cancer, NSCLC, mechanical ventilation, cystic fibrosis, pulmonary arterial hypertension (PAH), idiopathic pulmonary fibrosis, interstitial lung diseases, obstructive sleep apnea (OSA), and drugs. We found 12600 related articles in total in Google Scholar, 1807 in ScienceDirect, and 1081 in PubMed/Medline, published from 1980 to October 2014. 228 original investigation and review articles were eligible. There is rapidly increasing number of innovative articles, covering all the areas of modern respiratory medicine and expanding EBC potential clinical applications to other fields of internal medicine. However, the majority of published papers represent the results of small-scale studies and thus current knowledge must be further evaluated in large cohorts. In regard to the potential clinical use of EBC-analysis, several limitations must be pointed out, including poor reproducibility of biomarkers and absence of large surveys towards determination of reference-normal values. In conclusion, contemporary EBC-analysis is an intriguing achievement, but still in early stage when it comes to its application in clinical practice.
Investigation of Interfacial Phenomena During Condensation of Humid Air on a Horizontal Substrate
Directory of Open Access Journals (Sweden)
Tiwari Akhilesh
2013-12-01
Full Text Available The condensation phenomenon of humid air on solid substrates can occur in many applications, and it is known as one of the most difficult problem to deal with for the improvement of the quality of air in a closed environment. The present study was motivated by the investigation of the coupling between ventilation and condensation inside controlled ecological life support systems (CELSS, as it has an important role for higher plants growth in greenhouses and living conditions in manned spacecraft cabins, particularly in long duration space flights or in future space bases. It is well known that the enhancement of the gas exchange with leaves and the growth of plants are dependent on the organoleptic and/or the surrounding thermo-physical factors. Insufficient air movement around plants and condensation on plant leaves generally limit their growth by suppressing the gas diffusion in the leaf boundary-layer thereby decreasing photosynthetic and transpiration rates. Thus, the optimization of a CELSS will require the control of the airflow and concomitant gas/liquid transfer at the plant surfaces. The experimental and theoretical modeling of CELSS requires a comprehensive understanding of the micro to the macro levels of liquid gas phase transfer. Hence, an experimental set-up was developed at 1-g to evaluate the mass transfer coefficients due to condensation of humid air on specific geometries in well controlled environmental conditions. The goal was to establish correlations between the fluxes of mass and heat, the relative humidity and the mean flow for the development of theoretical models based on local transfer coefficients. The experiments were performed at ambient temperature, with a relative humidity between 35-70% and for a velocity range of 1.0-3.0 m.s−1.
Directory of Open Access Journals (Sweden)
Z.R. Wang
2017-09-01
Full Text Available The mechanically pumped two-phase loop (MPTL has the advantages of long distance heat transport, high heat density and good temperature control. On TZ1, the MPTL technology is adopted to support a series experiments of evaporation and condensation. The main objective is to provide accurate (±0.5 ℃ temperature control from −5 ℃ to 40 ℃ and remove 80 W heat from the experimental setup. In this paper, the requirements, system design, hardware and performance of the MPTL are introduced.
Extraction and evaluation of condensed tannins from bark of eleven species of trees from Costa Rica
International Nuclear Information System (INIS)
Aguilar Lopez, Jorge; Vega Guzman, Ileana; Borbon Alpizar, Henry; Soto Fallas, Roy Mario; Jaen Jimenez, Jean Carlo; Vargas Abarca, Ana Sofia; Jimenez Bonilla, Pablo; Herrera Nunez, Jacqueline
2012-01-01
A study is made regarding the nature and the amount of condensed tannin which can extract of bark from 11 tree species present in Costa Rica: guanacaste (Enterolobium cyclocarpum), cork oak (Licania arborea), jobo (Spondias mombin), pochote (Pachira quinata), loquat (Manilkara chicle), almond (Andira inermis), oak (Tabebuia rosea), cedar (Cedrela odorata), cenizaro (Samanea saman), pine (Pinus caribaea) and cypress (Cupressus lusitanica). The cortex samples were prepared, dried and extracted with ethanol. The ethanolic extracts were analyzed for condensed tannin content through the number of Stiasny, and characterized by infrared spectroscopy (FT-IR). The species with the highest proportion of extracted material were: guanacaste (9.5841% w/w), pochote (15.0066% w/w), pine (19.3400% w/w) and cypress (10.5300% w/w). The extracts with a higher proportion of condensed tannins have been: cork oak (61.9% w/w), jobo (66.1% w/w), pochote (72.8% w/w), loquat (50.5% w/w), cedar (72.7% w/w) and pine (70.7% w/w). (author) [es
International Nuclear Information System (INIS)
Yang, Chao; Chang, Chao; Song, Chengyi; Shang, Wen; Wu, Jianbo; Tao, Peng; Deng, Tao
2016-01-01
Highlights: • A flexible and high-performance heat pipe is fabricated. • Bending effect on thermal performance of flexible heat pipes is evaluated. • Theoretical analysis is carried out to reveal the change of thermal resistance with bending. • Thermal control of foldable electronics with flexible heat pipes is demonstrated. - Abstract: In this work, we report the fabrication and thermal performance evaluation of flexible heat pipes prepared by using a fluororubber tube as the connector in the adiabatic section and using strong base treated hydrophilic copper meshes as the wick structure. Deionized water was chosen as working fluid and three different filling ratios (10%, 20%, and 30%) of working fluid were loaded into the heat pipe to investigate its impact on thermal performance. The fabricated heat pipes can be easily bended from 0"o to 180"o in the horizontal operation mode and demonstrated consistently low thermal resistances after repeated bending. It was found that with optimized amount of working fluid, the thermal resistance of flexible heat pipes increased with larger bending angles. Theoretical analysis reveals that bending disturbs the normal vapor flow from evaporator to condenser in the heat pipe, thus leads to increased liquid–vapor interfacial thermal resistance in the evaporator section. The flexible heat pipes have been successfully applied for thermal control of foldable electronic devices showing superior uniform heat-transfer performance.
Capillary condensation onto titania (TiO2) nanoparticle agglomerates.
Kim, Seonmin; Ehrman, Sheryl H
2007-02-27
A capillary condensation process was developed for the purpose of forming interconnections between nanoparticles at low temperatures. The process was performed in a temperature-controlled flow chamber on nanoparticle agglomerates deposited at submonolayer coverage on a transmission electron microscope grid. The partial pressure of the condensing species, tetraethyl orthosilicate, and the temperature of the chamber were adjusted in order to obtain the various saturation conditions for capillary condensation. The modified samples were characterized by transmission electron microscopy (TEM), X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, BET surface area method, and scanning transmission electron microscopy with electron energy-loss spectrometry. Experimental results show that bridge-shaped layers were dominantly formed in the neck region between particles and were composed of amorphous silica. The analysis of TEM micrographs verified that the coverage of the layers is strongly dependent on the saturation ratio. Image analysis of TEM micrographs shows that this dependency is qualitatively in agreement with theoretical predictions based on the classical Kelvin equation for the specific geometries in our system.
Coherence and chaos in condensed matter
International Nuclear Information System (INIS)
Bishop, A.R.
1989-01-01
This paper discusses the following topics: nonlinearity in condensed matter; coherence and chaos in spatially extended condensed matter systems; nonlinearity and magnetism; and solitons and conducting polymers. 52 refs., 7 figs
Directory of Open Access Journals (Sweden)
Wang Wei
2016-01-01
Full Text Available When searching for the optimum condenser cooling water flow in a thermal power plant with natural draft cooling towers, it is essential to evaluate the outlet water temperature of cooling towers when the cooling water flow and inlet water temperature change. However, the air outlet temperature and tower draft or inlet air velocity are strongly coupled for natural draft cooling towers. Traditional methods, such as trial and error method, graphic method and iterative methods are not simple and efficient enough to be used for plant practice. In this paper, we combine Merkel equation with draft equation, and develop the coupled description for performance evaluation of natural draft cooling towers. This model contains two inputs: the cooling water flow, the inlet cooling water temperature and two outputs: the outlet water temperature, the inlet air velocity, equivalent to tower draft. In this model, we furthermore put forward a soft-sensing algorithm to calculate the total drag coefficient instead of empirical correlations. Finally, we design an iterative approach to solve this coupling model, and illustrate three cases to prove that the coupling model and solving approach proposed in our paper are effective for cooling tower performance evaluation.
Liang, Zhi; Keblinski, Pawel
2018-02-01
Using molecular dynamics simulations, we study evaporation and condensation of fluid Ar in the presence of a non-condensable Ne gas in a nanochannel. The evaporation and condensation are driven by the temperature difference, ΔTL, between the evaporating and condensing liquid surfaces. The steady-state evaporation and condensation fluxes (JMD) are also affected by the Ne concentration, ρNe, and the nanochannel length. We find that across a wide range of ΔTL and ρNe, JMD is in good agreement with the prediction from Stefan's law and from Schrage relationships. Furthermore, for ΔTL less than ˜20% of the absolute average temperature, we find that both steady-state heat and mass fluxes are proportional to ΔTL. This allows us to determine the interfacial resistance to the heat and mass transfer and compare it with the corresponding resistances in the gas phase. In this context, we derive an analytical expression for the effective thermal conductivity of the gas region in the nanochannel and the mass transport interfacial resistance equivalent length, i.e., the length of the nanochannel for which the resistance to the mass flow is the same as the interfacial resistance to the mass flow.
Analytical methodologies for broad metabolite coverage of exhaled breath condensate.
Aksenov, Alexander A; Zamuruyev, Konstantin O; Pasamontes, Alberto; Brown, Joshua F; Schivo, Michael; Foutouhi, Soraya; Weimer, Bart C; Kenyon, Nicholas J; Davis, Cristina E
2017-09-01
Breath analysis has been gaining popularity as a non-invasive technique that is amenable to a broad range of medical uses. One of the persistent problems hampering the wide application of the breath analysis method is measurement variability of metabolite abundances stemming from differences in both sampling and analysis methodologies used in various studies. Mass spectrometry has been a method of choice for comprehensive metabolomic analysis. For the first time in the present study, we juxtapose the most commonly employed mass spectrometry-based analysis methodologies and directly compare the resultant coverages of detected compounds in exhaled breath condensate in order to guide methodology choices for exhaled breath condensate analysis studies. Four methods were explored to broaden the range of measured compounds across both the volatile and non-volatile domain. Liquid phase sampling with polyacrylate Solid-Phase MicroExtraction fiber, liquid phase extraction with a polydimethylsiloxane patch, and headspace sampling using Carboxen/Polydimethylsiloxane Solid-Phase MicroExtraction (SPME) followed by gas chromatography mass spectrometry were tested for the analysis of volatile fraction. Hydrophilic interaction liquid chromatography and reversed-phase chromatography high performance liquid chromatography mass spectrometry were used for analysis of non-volatile fraction. We found that liquid phase breath condensate extraction was notably superior compared to headspace extraction and differences in employed sorbents manifested altered metabolite coverages. The most pronounced effect was substantially enhanced metabolite capture for larger, higher-boiling compounds using polyacrylate SPME liquid phase sampling. The analysis of the non-volatile fraction of breath condensate by hydrophilic and reverse phase high performance liquid chromatography mass spectrometry indicated orthogonal metabolite coverage by these chromatography modes. We found that the metabolite coverage
Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers
Energy Technology Data Exchange (ETDEWEB)
Edward Levy; Harun Bilirgen; John DuPoint
2011-03-31
Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants. The report describes: (1) An expanded data base on water and acid condensation characteristics of condensing heat exchangers in coal-fired units. This data base was generated by performing slip stream tests at a power plant with high sulfur bituminous coal and a wet FGD scrubber and at a power plant firing high-moisture, low rank coals. (2) Data on typical concentrations of HCl, HNO{sub 3} and H{sub 2}SO{sub 4} in low temperature condensed flue gas moisture, and mercury capture efficiencies as functions of process conditions in power plant field tests. (3) Theoretical predictions for sulfuric acid concentrations on tube surfaces at temperatures above the water vapor dewpoint temperature and below the sulfuric acid dew point temperature. (4) Data on corrosion rates of candidate heat exchanger tube materials for the different regions of the heat exchanger system as functions of acid concentration and temperature. (5) Data on effectiveness of acid traps in reducing sulfuric acid concentrations in a heat exchanger tube bundle. (6) Condensed flue gas water treatment needs and costs. (7) Condensing heat exchanger designs and installed capital costs for full-scale applications, both for installation immediately downstream of an ESP or baghouse and for installation downstream of a wet SO{sub 2} scrubber. (8) Results of cost-benefit studies of condensing heat exchangers.
Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers
Energy Technology Data Exchange (ETDEWEB)
Levy, Edward; Bilirgen, Harun; DuPont, John
2011-03-31
Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants. The report describes: • An expanded data base on water and acid condensation characteristics of condensing heat exchangers in coal-fired units. This data base was generated by performing slip stream tests at a power plant with high sulfur bituminous coal and a wet FGD scrubber and at a power plant firing highmoisture, low rank coals. • Data on typical concentrations of HCl, HNO{sub 3} and H{sub 2}SO{sub 4} in low temperature condensed flue gas moisture, and mercury capture efficiencies as functions of process conditions in power plant field tests. • Theoretical predictions for sulfuric acid concentrations on tube surfaces at temperatures above the water vapor dewpoint temperature and below the sulfuric acid dew point temperature. • Data on corrosion rates of candidate heat exchanger tube materials for the different regions of the heat exchanger system as functions of acid concentration and temperature. • Data on effectiveness of acid traps in reducing sulfuric acid concentrations in a heat exchanger tube bundle. • Condensed flue gas water treatment needs and costs. • Condensing heat exchanger designs and installed capital costs for full-scale applications, both for installation immediately downstream of an ESP or baghouse and for installation downstream of a wet SO{sub 2} scrubber. • Results of cost-benefit studies of condensing heat exchangers.
Energy Technology Data Exchange (ETDEWEB)
Yoo, Ji Min; Lee, Dong Hun; Jeong, Jae Jun [Pusan National University, Busan (Korea, Republic of)
2016-05-15
Condensation heat transfer under the presence of noncondensable gases (NCGs) is an important issue in nuclear safety because the presence of even a small quantity of NC gases in the vapor largely reduces the condensation rate. The extensive assessment of the condensation model of the safety analysis codes has been also performed. When NCGs are present, the condensation phenomenon is largely reduced by accumulated NCGs near the condensing surface. Since the total pressure remains constant, the partial pressure of vapor at the liquid-vapor interface is lower than that in the bulk mixture, providing the driving force for vapor diffusion towards the liquid-vapor interface. The main objective of the present study is the assessment of the condensation heat transfer model of the severe accident code MELCOR 1.8.6 under the presence of NCGs. In this study, the condensation heat transfer model of the MELCOR 1.8.6 is assessed using various experiments which have 4 different types of geometry. Through the comparison of the results, it was shown that the MELCOR code generally under-predicts the condensation heat transfer except the condensation on outer surface of vertical pipes and improvement is needed for other geometries.
Performance evaluation of an ejector subcooled vapor-compression refrigeration cycle
International Nuclear Information System (INIS)
Xing, Meibo; Yan, Gang; Yu, Jianlin
2015-01-01
Highlights: • An ejector subcooled vapor-compression refrigeration cycle is proposed. • The performance of the cycle with ejector subcooling is evaluated theoretically. • Increase in refrigeration capacity can be achieved by the ejector subcooled cycle. • The new cycle exhibits higher COP compared to the basic single-stage cycle. • Performance of the new cycle depends on the operation pressures of the ejector. - Abstract: In this study, a novel vapor-compression refrigeration cycle with mechanical subcooling using an ejector is proposed to improve the performance of a conventional single-stage vapor-compression refrigeration cycle. In the theoretical study, a mathematical model is developed to predict the performance of the cycle by using R404A and R290, and then compared with that of the conventional refrigeration cycle. The simulation results show that the performance of the ejector subcooled cycle is better than that of the conventional cycle. When the evaporator temperature ranges from −40 to −10 °C and the condenser temperature is 45 °C, the novel cycle displays volumetric refrigeration capacity improvements of 11.7% with R404A and 7.2% with R290. And the novel cycle achieves COP improvements of 9.5% with R404A and 7.0% with R290. In addition, the improvement of the COP and cooling capacity of this novel cycle largely depends on the operation pressures of the ejector. The potential practical advantages offered by the cycle may be worth further attention in future studies
The phase transition to an inhomogeneous condensate state
International Nuclear Information System (INIS)
Voskresensky, D.N.
1984-01-01
The Lagrangian (free energy) of the model with a complex scalar order parameter in which the phase transition to an inhomogeneous condensate state exists is constructed in the coordinate representation. In the case of condensation of charged particles (for example paired electrons) interaction with the electromagnetic field is included. The excitation spectrum in the presence of the condensate is found. The oscillations are strongly anisotropic. It is shown that superfluidity is absent for an uncharged system but that the charged one has the property of superconductivity. The important role of thermal fluctuations is demonstrated. They drastically change the behaviour of the condensate system. The condensation in a finite system is considered. A study is carried out for the behaviour of an inhomogeneous condensate in magnetic field. It is shown that the inhomogeneous condensate is a type II superconductor with Ginzburg-Landau parameter kappa >> 1, but that the structure of the mixed state of the system is unusual - consisting of plane layers of the normal phase, when Hsub(c1)< H< H'sub(c2). The distribution of condensate in the strong magnetic field H'sub(c2)< H< Hsub(c2) is also studied. (Auth.)
International Nuclear Information System (INIS)
Berrichon, J.D.; Louahlia-Gualous, H.; Bandelier, Ph.; Bariteau, N.
2014-01-01
Highlights: • Theoretical model for condensation heat transfer at very low pressure is developed using only one iterative loop. • Experimental results on steam and air steam condensation heat transfer at very low pressure are presented. • The developed model gives the good predictions for local condensation heat transfer at low pressure. • A maximal deterioration of 50% in condensation heat transfer is obtained at low pressure for air fraction of 4%. • A new correlation including effect of a wavy film surface for steam condensation at low pressure is suggested. - Abstract: This paper presents experimental investigation on the influence of very low pressure on local and average condensation heat transfer in a vertical tube. Furthermore, this paper develops an analytical study for film condensation heat transfer coefficient in the presence of non-condensable gas inside a vertical tube. The condensate film thickness is calculated for each location in a tube using mass and heat transfer analogy. The effects of interfacial shear stress and waves on condensate film surface are included in the model. The comparative studies show that the present model well predicts the experimental data of Khun et al. [1]for local condensation of steam air mixture at high pressure. Different correlations defined for condensation heat transfer are evaluated. It is found that the correlations of Cavallini and Zecchin [2] and Shah [3] are the closest to the calculated steam condensation local heat transfer coefficient. The model gives a satisfactory accuracy with the experimental results for condensation heat transfer at very low pressure. The mean deviation between the predictions of the theoretical model with the measurements for pure saturated vapor is 12%. Experimental data show that the increase of air fraction to 4% deteriorates condensation heat transfer at low pressure up to 50%
Condensing and water supplying systems in an atomic power plant
International Nuclear Information System (INIS)
Shinmura, Akira.
1975-01-01
Object: To reduce heat loss and eliminate accumulation of drain in water supplying and heating units in an atomic power plant by providing a direct contact type drain cooler between a gland-exhauster vapor condenser and a condensing and de-salting means, the drain from each water supplying and heating unit being collected in said cooler for heating the condensed water. Structure: Condensed water from a condenser is fed by a low pressure condensing pump through an air ejector and gland-exhauster vapor condenser to the direct-contact type drain cooler and is condensed in each water supply heater. Next, it is heated by drain fed through a drain level adjuster valve and an orifice and then forced by a medium pressure condenser pump into the condensing and de-salting means. It is then supplied by a high pressure condensing pump into the successive water supply heater. (Kamimura, M.)
Energy Technology Data Exchange (ETDEWEB)
Wicker, K.
2006-04-15
The humble condenser is among the biggest contributors to a steam power plant's efficiency. But although a clean condenser can provide great economic benefit, a dirty one can raise plant heat rate, resulting in large losses of generation revenue and/or unnecessarily high fuel bills. Conventional methods for cleaning fouled tubes range form chemicals to scrapers to brushes and hydro-blasters. This article compares the available options and describes how one power station, Omaha Public Power District's 600 MW North Omaha coal-fired power station, cleaned up its act. The makeup and cooling water of all its five units comes from the Missouri River. 6 figs.
On the occurrence and detectability of Bose-Einstein condensation in helium white dwarfs
International Nuclear Information System (INIS)
Benvenuto, O.G.; Vito, M.A. De
2011-01-01
It has been recently proposed that helium white dwarfs may provide promising conditions for the occurrence of the Bose-Einstein condensation. The argument supporting this expectation is that in some conditions attained in the core of these objects, the typical De Broglie wavelength associated with helium nuclei is of the order of the mean distance between neighboring nuclei. In these conditions the system should depart from classical behavior showing quantum effects. As helium nuclei are bosons, they are expected to condense. In order to explore the possibility of detecting the Bose-Einstein condensation in the evolution of helium white dwarfs we have computed a set of models for a variety of stellar masses and values of the condensation temperature. We do not perform a detailed treatment of the condensation process but mimic it by suppressing the nuclei contribution to the equation of state by applying an adequate function. As the cooling of white dwarfs depends on average properties of the whole stellar interior, this procedure should be suitable for exploring the departure of the cooling process from that predicted by the standard treatment. We find that the Bose-Einstein condensation has noticeable, but not dramatic effects on the cooling process only for the most massive white dwarfs compatible with a helium dominated interior ( ≈ 0.50M s un) and very low luminosities (say, Log(L/L s un) < −4.0). These facts lead us to conclude that it seems extremely difficult to find observable signals of the Bose-Einstein condensation. Recently, it has been suggested that the population of helium white dwarfs detected in the globular cluster NGC 6397 is a good candidate for detecting signals of the Bose-Einstein condensation. We find that these stars have masses too low and are too bright to have an already condensed interior
Systematic text condensation: a strategy for qualitative analysis.
Malterud, Kirsti
2012-12-01
To present background, principles, and procedures for a strategy for qualitative analysis called systematic text condensation and discuss this approach compared with related strategies. Giorgi's psychological phenomenological analysis is the point of departure and inspiration for systematic text condensation. The basic elements of Giorgi's method and the elaboration of these in systematic text condensation are presented, followed by a detailed description of procedures for analysis according to systematic text condensation. Finally, similarities and differences compared with other frequently applied methods for qualitative analysis are identified, as the foundation of a discussion of strengths and limitations of systematic text condensation. Systematic text condensation is a descriptive and explorative method for thematic cross-case analysis of different types of qualitative data, such as interview studies, observational studies, and analysis of written texts. The method represents a pragmatic approach, although inspired by phenomenological ideas, and various theoretical frameworks can be applied. The procedure consists of the following steps: 1) total impression - from chaos to themes; 2) identifying and sorting meaning units - from themes to codes; 3) condensation - from code to meaning; 4) synthesizing - from condensation to descriptions and concepts. Similarities and differences comparing systematic text condensation with other frequently applied qualitative methods regarding thematic analysis, theoretical methodological framework, analysis procedures, and taxonomy are discussed. Systematic text condensation is a strategy for analysis developed from traditions shared by most of the methods for analysis of qualitative data. The method offers the novice researcher a process of intersubjectivity, reflexivity, and feasibility, while maintaining a responsible level of methodological rigour.
The effect of non-condensable gas on direct contact condensation of steam/air mixture
International Nuclear Information System (INIS)
Lee, H. C.; Park, S. K.; Kim, M. H.
1998-01-01
To investigate the effects of noncondensable gas on the direct contact film condensation of vapor mixture, a series of experiments has been carried out. The rectangular duct inclined 87.deg. to the horizontal plane was used for this experiment. The average heat transfer coefficient of the steam-air mixture was obtained at the atmospheric pressure with four main parameters, air-mass fraction, vapor velocity, film Reynolds number,and the degree of water film subcooling having an influence on the condensation heat transfer coefficient. With the analysis on 88 cases of experiments, a correlation of the average Nusselt number for direct contact film condensation of steam-air mixture at a vertical wall proposed as functions of film Reynolds number, mixture Reynolds number, air mass fraction, and Jacob number. The average heat transfer coefficient for steam-air mixture condensation decreased significantly while air mass fraction increases with the same inlet mixture velocity and inlet film temperature. The average heat transfer coefficients also decreased with the degree of film subcooling increasing and were scarcely affected by film Reynolds number below the mixture Reynolds number about 30,000
Some issues in the ghost condensation scenario
International Nuclear Information System (INIS)
Anisimov, A.
2004-01-01
In the recently proposed 'ghost condensation' scenario a model of consistent infrared modification of gravity was suggested. We first review the basic ideas of this scenario. We discuss various phenomenological aspects of the ghost condensation, such as stability of the condensate, bounds on the UV cut-off scale of the corresponding effective field theory and other issues. (author)
Thermodynamic entanglement of magnonic condensates
Yuan, H. Y.; Yung, Man-Hong
2018-02-01
Over the past decade, significant progress has been achieved to create Bose-Einstein condensates (BECs) of magnetic excitations, i.e., magnons, at room temperature, which is a novel quantum many-body system with a strong spin-spin correlation, and contains potential applications in magnonic spintronics. For quantum information science, the magnonic condensates can become an attractive source of quantum entanglement, which plays a central role in most of the quantum information processing tasks. Here we theoretically study the entanglement properties of a magnon gas above and below the condensation temperature. We show that the thermodynamic entanglement of the spins is a manifestation of the off-diagonal long-range order; the entanglement of the condensate does not vanish, even if the spins are separated by an infinitely long distance, which is fundamentally distinct from the normal magnetic ordering below the Curie temperature. In addition, the phase-transition point occurs when the derivative of the entanglement changes abruptly. These results provide a theoretical foundation for a future investigation of the magnon BEC in terms of quantum entanglement.
Becker, E D
2013-01-01
Recommendations for the Presentation of Infrared Absorption Spectra in Data Collections-A. Condensed Phases presents the recommendations related to the infrared spectra of condensed phase materials that are proposed for permanent retention in data collections. These recommendations are based on two reports published by the Coblentz Society. This book emphasizes the three levels of quality evaluation for infrared spectra as designated by the Coblentz Society, including critically defined physical data, research quality analytical spectra, and approved analytical spectra. This text discusses the
Entropy generation in a condenser and related correlations
Directory of Open Access Journals (Sweden)
Askowski Rafał
2015-06-01
Full Text Available The paper presents an analysis of relations describing entropy generation in a condenser of a steam unit. Connections between entropy generation, condenser ratio, and heat exchanger effectiveness, as well as relations implied by them are shown. Theoretical considerations allowed to determine limits of individual parameters which describe the condenser operation. Various relations for average temperature of the cold fluid were compared. All the proposed relations were verified against data obtained using a simulator and actual measurement data from a 200 MW unit condenser. Based on data from a simulator it was examined how the sum of entropy rates, steam condenser effectiveness, terminal temperature difference and condenser ratio vary with the change in the inlet cooling water temperature, mass flow rate of steam and the cooling water mass flow rate.
Condensational theory of stationary tornadoes
International Nuclear Information System (INIS)
Makarieva, A.M.; Gorshkov, V.G.; Nefiodov, A.V.
2011-01-01
Using the Bernoulli integral for air streamline with condensing water vapor a stationary axisymmetric tornado circulation is described. The obtained profiles of vertical, radial and tangential velocities are in agreement with observations for the Mulhall tornado, world's largest on record and longest-lived among the three tornadoes for which 3D velocity data are available. Maximum possible vortex velocities are estimated. -- Highlights: → Water vapor condensation causes a logarithmic drop of air pressure towards tornado center. → The first ever theoretical description of tornado velocities is obtained. → The maximum vortex velocity grows logarithmically with decreasing tornado eye radius. → Air motion with high velocities can only develop in sufficiently large condensation areas.
Dynamics of inhomogeneous chiral condensates
Carlomagno, Juan Pablo; Krein, Gastão; Kroff, Daniel; Peixoto, Thiago
2018-01-01
We study the dynamics of the formation of inhomogeneous chirally broken phases in the final stages of a heavy-ion collision, with particular interest on the time scales involved in the formation process. The study is conducted within the framework of a Ginzburg-Landau time evolution, driven by a free energy functional motivated by the Nambu-Jona-Lasinio model. Expansion of the medium is modeled by one-dimensional Bjorken flow and its effect on the formation of inhomogeneous condensates is investigated. We also use a free energy functional from a nonlocal Nambu-Jona-Lasinio model which predicts metastable phases that lead to long-lived inhomogeneous condensates before reaching an equilibrium phase with homogeneous condensates.
Study on corrosion of thermal power plant condenser tubes
Energy Technology Data Exchange (ETDEWEB)
Mohammadi, Abdolreza Rashidi; Zhaam, Ali Akbar [Niroo Research Institute, end of Poonak Bakhtari blvd., Shahrak Ghods, Tehran (Iran)
2004-07-01
The aim of this investigation is to study kinds of corrosion mechanisms in thermal power plant condenser tubes. Condenser is a shell and tube heat exchanger in which cooling water flows through its tubes. While the steam from low pressure turbine passes within condenser tubes, it is condensed by cooling water. The exhausted steam from low pressure turbine is condensed on external surface of condenser tubes and heat is transferred to cooling water which flow into tubes. Tubes composition is usually copper-based alloys, stainless steel or titanium. Annual damages due to corrosion cause much cost for replacement and repairing metallic equipment and installations in electric power industry. Because of existence of different contaminants in water and steam cycle, condenser tubes surfaces are exposed to corrosion. Contaminants like oxygen, carbon dioxide, chloride ion and ammonia in water and steam cycle originate several damages such as pitting and crevice corrosion, erosion, galvanic attack, SCC, condensed corrosion, de-alloying in thermal power plant condenser. The paper first states how corrosion damage takes place in condensers and then introduces types of usual alloys used in condensers and also their corrosion behavior. In continuation, a brief explanation is presented about kinds of condenser failures due to corrosion. Then, causes and locations of different mechanisms of corrosion events on condenser tubes and effects of different parameters such as composition, temperature, chloride and sulfide ion concentration, pH, water velocity and biological precipitation are examined and finally protection methods are indicated. Also some photos of tubes specimens related to power plants are studied and described in each case of mentioned mechanisms. (authors)
Energy Technology Data Exchange (ETDEWEB)
Eckels, S J; Tesene, B A
1999-07-01
Local and average heat transfer coefficients during condensation are reported for R-22, R-134a, R-410a, and R-407c in one smooth tube and three enhanced surface tubes. The test tubes included a 3/8 inch outer diameter smooth tube, a 3/8 inch outer diameter microfin tube, a 5/16 inch outer diameter microfin tube, and a 5/8 inch outer diameter microfin tube. The local and average heat transfer coefficients were measured over a mass flux range of 92,100 lb/ft{sup 2}{center_dot}h to 442,200 lb/ft{sup 2}{center_dot}h and at saturation temperatures of 104 F and 122 F. A comparison of the performance of the different refrigerants reveals that R-134a has the highest heat transfer performance followed by R-22 and R-410a, which have similar performances. In general, R-407c had the lowest performance of the refrigerants tested. The microfin tube more than doubles the heat transfer coefficient compared to the smooth tube for all refrigerants at the low mass fluxes, but only increases the heat transfer coefficients by 50% at the highest mass flux tested. The measured heat transfer coefficients are also compared with a number of correlations for condensation.
Strangeness condensation and ''clearing'' of the vacuum
International Nuclear Information System (INIS)
Brown, G.E.; Kubodera, Kuniharu; Rho, M.; State Univ. of New York, Stony Brook
1987-01-01
We show that a substantial amount of strange quark-antiquark pair condensates in the nucleon required by the πN sigma term implies that kaons could condense in nuclear matter at a density about three times that of normal nuclear matter. This phenomenon can be understood as the ''cleansing'' of qanti q condensates from the QCD vacuum by a dense nuclear matter, resulting in a (partial) restoration of the chiral symmetry explicitly broken in the vacuum. It is suggested that the condensation signals a new phase distinct from that of quark plasma and that of ordinary dense hadronic matter. (orig.)
International Nuclear Information System (INIS)
Leyer, S.; Maisberger, F.; Herbst, V.; Doll, M.; Wich, M.; Wagner, T.
2010-01-01
KERENA TM (SWR1000) is an innovative boiling water reactor concept with passive safety systems. In order to verify the functionality of the passive components required for the transient and accident management, the test facility INKA (Integral-Versuchstand Karlstein) is build in Karlstein (Germany). The key elements of the KERENA TM passive safety concept -the Emergency Condenser, the Containment Cooling Condenser, the Passive Core Flooding System and the Passive Pressure Pulse Transmitter - will be tested at INKA. The Emergency Condenser system transfers heat from the reactor pressure vessel to the core flooding pools of the containment. The heat introduced into the containment during accidents will be transferred to the main heat sink for passive accident management (Shielding/Storage Pool) via the Containment Cooling Condensers. Therefore both systems are part of the passive cooling chain connecting the heat source RPV (Reactor Pressure Vessel) with the heat sink. At the INKA test facility both condensers are tested in full scale setup, in order to determine the heat transfer capacity as function of the main input parameters. For the EC these are the RPV pressure, the RPV water level, the containment pressure and the water temperature of the flooding pools. For the Containment Cooling Condenser the heat transfer capacity is a function of the containment pressure, the water temperature of the Shielding/Storage Pool and the fraction of non -condensable gases in the containment. The status of the test program and the available test data will be presented. An outlook of the future test of the passive core flooding system and the integral system test including also the passive pressure pulse transmitter will be given. (authors)
ANALISIS PENGGUNAAN WATER COOLED CONDENSER PADA MESIN PENGKONDISIAN UDARA PAKET (AC WINDOW
Directory of Open Access Journals (Sweden)
IKG Wirawan
2012-11-01
Full Text Available One of the important aspects in thermal design is refrigeration and air conditioning. Working principle of air conditioning is absorption and thermal dissipation process. Condenser is main component to release the heat from refrigerant to the cooling medium. In the present research, water cooled condenser was used to replace the commonly air condenser. Pressure and temperature at some section of the components were observed in order to examine the performance of the air conditioning system. The results showed that the COP varied from 9.66 to 12.4; refrigerationg effect varied from 1.31 kW to 1.86 kW; cooling capacity varied from 0.38 TR to 0.53 TR; and heat transfer varied from 2.2 kW to 2.98 kW.
Directory of Open Access Journals (Sweden)
Shempelev A. G.
2017-08-01
Full Text Available The aim of the article is to analyze the influence of different factors on the oxygen content in the condensate using the example of the condenser of the steam turbine unit T-110/120-130. For the first time, the authors of the article analyze in details how the basic parameters of the condenser's operation (the condenser heat load, the flow and temperature of the cooling water, the air inflow in the condenser, the condition of the heat exchange surface influence the oxygen content of the condensate. The authors come to the conclusion that with standard air inflow in the vacuum system, the equilibrium oxygen content, which corresponds to the norms in the condensate at the condenser outlet, is only possible in its operation modes when the steam flow to the condenser is more than 50% of the nominal flow and cooling water temperatures are equal to or greater than calculated for this type of condenser. The conclusions are confirmed by the experimental material. The results of the research are the basis for the development of measures aimed to increase the deaerating capacity of condensers depending on specific operating conditions.
International Nuclear Information System (INIS)
Su Jiqiang; Sun Zhongning; Fan Guangming; Guo Zixuan
2014-01-01
In order to investigate the influence of various parameters in the steam condensation heat transfer process with non-condensable gas, and to get a more suitable empirical correlation, the wall under-cooling, pressure and the content of non-condensable gas were studied outside a vertical tube by experiments. The results showed that: at the same pressure, the relationship between wall sub-cooling and HTC is exponential, and helium stratification does not happen within the experimental range. Based on the analysis of various experimental variables, combined with a large number of experimental data, a wider scope of application of the empirical correlation associated is obtained with the experimental value of the error within ±20%. (authors)
Continuous condensation device for vapors in the atmosphere
International Nuclear Information System (INIS)
Tricot, M.
1983-01-01
The continuous condensation device for vapors from the atmosphere is such those in which this atmosphere circulates in contact with a cold source involving the condensation of these vapors. It includes a thermoelectric module using the Peltier effect; the hot side is bonded to a heat sink and the cold side is in contact with an insulated condensation chamber in which flows the atmosphere charged with vapors to be condensated. The condensation chamber has a metallic structure through which a low voltage direct current is passed; this structure has small blades with holes, through which the condensate flows under gravity in the lower part of the chamber which have a hole to evacuate this liquid. The thermoelectric module comprises an assembly of thermocouples made of an array of alloy plates. The temperature inside the condensation chamber is maintained at just above 0 0 C. This device is used for the sampling of atmosphere water especially in the determination of tritium content of the atmosphere around nuclear installations [fr
International Nuclear Information System (INIS)
Schena, E; Saccomandi, P; Cappelli, S; Silvestri, S
2013-01-01
Heated wire humidifiers (HWHs) are widely used to heat and humidify gases during mechanical ventilation. The control strategy implemented on commercial HWHs, based on maintaining constant gas temperature at the chamber outlet, shows weaknesses: humidifying performances depend on environmental temperature and ventilatory settings, and often condensation occurs. Herein, we analyzed in vitro HWH performances focusing on the condensation amount according to ventilatory settings. We used a physical model to define the parameters which mainly influence the HWH performances. In order to investigate the influence of minute volume (MV) and frequency rate (f r ) on condensation, the other influencing parameters were kept constant during experiments, and we introduced a novel approach to estimate the condensation. The method, based on measuring the condensed vapor mass (Δm), provided more objective information than the visual-based scale used in previous studies. Thanks to both the control of other influencing factors and the accurate Δm measures, the investigation showed the Δm increase with MV and f r . Substantial condensation after 7 h of ventilation and the influence of MV and f r on Δm (i.e., Δm = 3 g at MV = 1.5 L min −1 and f r = 8 bpm and Δm = 9.4 g at MV = 8 L min −1 and f r = 20 bpm) confirm the weaknesses of 'single-point temperature' control strategies. (paper)
Asymmetric condensed dark matter
Energy Technology Data Exchange (ETDEWEB)
Aguirre, Anthony; Diez-Tejedor, Alberto, E-mail: aguirre@scipp.ucsc.edu, E-mail: alberto.diez@fisica.ugto.mx [Santa Cruz Institute for Particle Physics and Department of Physics, University of California, Santa Cruz, CA, 95064 (United States)
2016-04-01
We explore the viability of a boson dark matter candidate with an asymmetry between the number densities of particles and antiparticles. A simple thermal field theory analysis confirms that, under certain general conditions, this component would develop a Bose-Einstein condensate in the early universe that, for appropriate model parameters, could survive the ensuing cosmological evolution until now. The condensation of a dark matter component in equilibrium with the thermal plasma is a relativistic process, hence the amount of matter dictated by the charge asymmetry is complemented by a hot relic density frozen out at the time of decoupling. Contrary to the case of ordinary WIMPs, dark matter particles in a condensate must be lighter than a few tens of eV so that the density from thermal relics is not too large. Big-Bang nucleosynthesis constrains the temperature of decoupling to the scale of the QCD phase transition or above. This requires large dark matter-to-photon ratios and very weak interactions with standard model particles.
Decay of non-equilibrium polariton condensate in semiconductors
International Nuclear Information System (INIS)
Beloussov, I.V.; Shvera, Y.M.
1993-08-01
Excitation dynamics of polariton quantum fluctuations arising in direct-gap semi-conductor as a result of parametric decay of non-equilibrium polariton condensate with non-zero wave vector is studied. The predominant mechanism of polariton scattering is supposed to be exciton-exciton interaction. Steady state which corresponds to the case of dynamic equilibrium between the polariton condensate and quantum fluctuations is obtained. Distribution functions of non-condensate polaritons are localized in the resonant regions, corresponding to two-particle excitation of polaritons from the condensate. The spectrum of elementary excitations in steady state coincides with usual polariton energy with the shift proportional to initial density of polariton condensate. (author). 25 refs
International Nuclear Information System (INIS)
Maheshwari, N.K.; Saha, D.; Sinha, R.K.; Aritomi, M.
2003-01-01
A passive containment cooling system with immersed condensers has been proposed as one of the alternatives for the advanced heavy water reactor (AHWR) being designed in India. The system removes residual/decay heat released into the containment through the immersed condensers kept in a pool of water following loss of coolant accident. An important aspect of the immersed condensers is the potential degradation of its performance due to the presence of noncondensable gases. Experiments are performed to obtain reliable data on condensation phenomena in presence of air. These experiments are conducted on full-scale tubes of condensers immersed in a pool of water maintaining similar conditions as in the prototype of AHWR. A method has been proposed for the determination of the local heat transfer rate using correlations given in literature. The parametric effects of air mass fraction, pressure, steam flow, etc. on condensation heat transfer in presence of noncondensable gas have been studied. The experimental results are compared with the correlations given in literature. (orig.)
Crud removal with deep bed type condensate demineralizer in Tokai-2 BWR
International Nuclear Information System (INIS)
Abe, Ayumi; Takiguchi, Hideki; Numata, Kunio; Saito, Toshihiko
1996-01-01
The major objective and functions for the installation of the deep bed type condensate polishers in BWR power plants is to remove both ionic impurities caused by sea water leakage and suspended impurities called crud mainly consisting of metal oxides which are produced from metal corrosion. In considering the reduction of occupational radiation exposure level, it is extremely important to remove the crud effectively. In recent Japanese BWR power plants, condensate pre-filters with powdered ion exchange resins or with hollow fiber membrane have been installed to remove the crud at the upper stream of the deep bed polishers. In such plants, the crud removal is conventionally the secondary objective for the deep bed polishers. The Japan Atomic Power Company has introduced the small particle ion exchange resin and a soak regeneration method since April 1985, and then applied the low cross-linked resin since July 1995 at Tokai-2 Power Station, to improve the crud removal performance by using only deep bed type condensate demineralizer, and as a result condensate demineralizer outlet iron level has been kept below 1 ppb since 1991
Energy Technology Data Exchange (ETDEWEB)
Leonardi, Tauna [Schlumberger, 14910 Airline Rd., Rosharon, TX 77583 (United States)]. E-mail: Tleonardi@slb.com; Ishii, Mamoru [School of Nuclear Engineering, Purdue University, West Lafayette, IN 47907 (United States)]. E-mail: Ishii@ecn.purdue.edu
2006-09-15
Noncondensable gases that come from the containment and the interaction of cladding and steam during a severe accident deteriorate a passive containment cooling system's performance by degrading the heat transfer capabilities of the condensers in passive containment cooling systems. This work contributes to the area of modeling condensation heat transfer with noncondensable gases in integral facilities. Previously existing correlations and models are for the through-flow of the mixture of steam and the noncondensable gases and this may not be applicable to passive containment cooling systems where there is no clear passage for the steam to escape. This work presents a condensation heat transfer model for the downward cocurrent flow of a steam/air mixture through a condenser tube, taking into account the atypical characteristics of the passive containment cooling system. An empirical model is developed that depends on the inlet conditions, including the mixture Reynolds number and noncondensable gas concentration.
Biomolecular condensates: organizers of cellular biochemistry.
Banani, Salman F; Lee, Hyun O; Hyman, Anthony A; Rosen, Michael K
2017-05-01
Biomolecular condensates are micron-scale compartments in eukaryotic cells that lack surrounding membranes but function to concentrate proteins and nucleic acids. These condensates are involved in diverse processes, including RNA metabolism, ribosome biogenesis, the DNA damage response and signal transduction. Recent studies have shown that liquid-liquid phase separation driven by multivalent macromolecular interactions is an important organizing principle for biomolecular condensates. With this physical framework, it is now possible to explain how the assembly, composition, physical properties and biochemical and cellular functions of these important structures are regulated.
Active condensation of water by plants
Directory of Open Access Journals (Sweden)
Prokhorov Alexey Anatolievich
2013-10-01
Full Text Available This paper is devoted to some peculiarities of water condensation on the surface of plants . Arguments in support of the hypothesis that in decreasing temperature of leaves and shoots below the dew point, the plant can actively condense moisture from the air, increasing the duration of dewfall are presented. Evening dewfall on plant surfaces begins before starting the formation of fog. Morning condensation continues for some time after the air temperature exceeds the dew point . The phenomenon in question is found everywhere, but it is particularly important for plants in arid ecosystems.
Landau-Migdal parameters and pion condensation
Energy Technology Data Exchange (ETDEWEB)
Tatsumi, Toshitaka [Department of Physics, Kyoto Univ., Kyoto (Japan)
1999-08-01
The possibility of pion condensation, one of the long-standing issues in nuclear physics, is reexamined in the light of the recent experimental data on the giant Gamow-Teller resonance. The experimental result tells that the coupling of nucleon particle-hole states with {delta} isobar-hole states in the spin-isospin channel should be weaker than that previously believed. It, in turn, implies that nuclear matter has the making of pion condensation at low densities. The possibility and implications of pion condensation in the heavy-ion collisions and neutron stars should be seriously reconsidered. (author)
Condensation phenomena in two-flavor scalar QED at finite chemical potential
Schmidt, Alexander; Gattringer, Christof
2014-01-01
We study condensation in two-flavored, scalar QED with non-degenerate masses at finite chemical potential. The conventional formulation of the theory has a sign problem at finite density which can be solved using an exact reformulation of the theory in terms of dual variables. We perform a Monte Carlo simulation in the dual representation and observe a condensation at a critical chemical potential $\\mu_c$. After determining the low-energy spectrum of the theory we try to establish a connection between $\\mu_c$ and the mass of the lightest excitation of the system, which are naively expected to be equal. It turns out, however, that the relation of the critical chemical potential to the mass spectrum in this case is non-trivial: Taking into account the form of the condensate and making some simplifying assumptions we suggest an adequate explanation which is supported by numerical results.
In-service inspection of condenser tubes by means of electrochemical methods
International Nuclear Information System (INIS)
Taelemans, G.
The commissioning of an increasing number of large nuclear power plants involves an increased significance of such condenser tube problems as: - erosion on tube ends, - generalized corrosion and pitting corrosion, - deposits in the tubes. In order to solve such problems, investigations were performed especially focused on a measurement technique that enables in-service behaviour of condenser tubes to be monitored. For such a purpose, measurement of the polarization resistance has been adopted. The existing corrosion products and scaled-off iron oxides were eliminated by means of a carborundum balls processing, as clearly appears from polarization resistance reduction. Then iron sulphate was injected in order to build a new and better protective layer. In addition, the tube was kept clean by means of foam rubber balls. There is a second implementation area: fouled condenser tubes. A significant polarization resistance reduction is noted during the acid cleaning. (orig.) [de
Directory of Open Access Journals (Sweden)
Egi Agustian
2015-06-01
Full Text Available Patchouli oil is an important material for aromatherapy industries and made from patchouli leaves by steam distillation. The important parts of steam distillation is condenser. The problem is process of farmer's patchouli based on experience not used chemical process of steam distillation cause not effective and efficient. The study was designed of condensers on steam distillation for patchouli leaves. Specification of condenser type is shell and tube, stainless steel material and water as coolant. Tubing sized is ¼ inch with 500 mm of length and 24 pieces. Shell measuring 2.5 inch and 600 mm of length. The performance of condenser gave the efficiency at 94.51%. The process condition of ratio stems to leaves is 5:6 and 4.5 hours was considered ideal for steam distillation. The used of energy is lowest cause the efficiency condenser and yield will be higher. Patchouli oil yield of 2.39% and patchouli alcohol content is 35.65%.
Kinetics of mineral condensation in the solar nebula
International Nuclear Information System (INIS)
Grove, T.L.
1987-01-01
A natural extension of the type of gas-mineral-melt condensation experiments is to study the gas-mineral-melt reaction process by controlling the reaction times of appropriate gas compositions with silicate materials. In a condensing and vaporizing gas-solid system, important processes that could influence the composition of and speciation in the gas phase are the kinetics of vaporization of components from silicate crystals and melts. The high vacuum attainable in the space station would provide an environment for studying these processes at gas pressures much lower than those obtainable in experimental devices operated at terrestrial conditions in which the gas phase and mineral or melt would be allowed to come to exchange equilibrium. Further experiments would be performed at variable gas flow rates to simulate disequilibrium vapor fractionation. In this type of experiment it is desirable to analyze directly the species in the gas phase in equilibrium with the condensed silicate material. This analytical method would provide a direct determination of the species present in the gas phase. Currently, the notion of gas speciation is based on calculations from thermodynamic data. The proposed experiments require similar furnace designs and use similar experimental starting compositions, pressures, and temperatures as those described by Mysen
Evaluation to Mitigate Secondary System Peak Pressure for Loss of Condenser Vacuum Event
Energy Technology Data Exchange (ETDEWEB)
Choi, Bong Oh; Park, Jong Cheol; Park, Min Soo; Lee, Gyu Cheon; Kim, Shin Whan [KEPCO E and C, Inc., Daejeon (Korea, Republic of)
2015-10-15
In this paper, countermeasures to compensate the increased secondary pressure are introduced and evaluated. From the standpoint of the secondary system pressurization, consideration of the PPCS may result in a conservative secondary system peak pressure. The control systems are generally credited for the safety analysis if the analysis produces conservative results. However, in most of all non-loss of coolant accident (non-LOCA) events, the control system helps to mitigate a transient state. Accordingly, the safety analysis of non-LOCA assumes the control systems are in the manual mode of operation. The loss of condenser vacuum event (LOCV) is a typical anticipated operational occurrence (AOO) which results in an increase in primary and secondary system pressure. The pressurizer (PZR) pressure control system (PPCS) will function to reduce the primary system pressure increase during the transient. Therefore, it is assumed to be in manual mode and credit is not taken for its functioning. However, crediting the function of PPCS has been found to be more conservative with regard to the secondary system pressure. This is due to the delay of the reactor trip on high pressurizer pressure (HPP) and results in an increase in secondary pressure.
Condenser design optimization and operation characteristics of a novel miniature loop heat pipe
International Nuclear Information System (INIS)
Wan Zhenping; Wang Xiaowu; Tang Yong
2012-01-01
Highlights: ► A novel miniature LHP (mLHP) system was presented. ► Optimal design of condenser was considered. ► The heat transfer performance was investigated experimentally. - Abstract: Loop heat pipe (LHP) is a promising means for electronics cooling since LHP is a exceptionally efficient heat transfer device. In this paper, a novel miniature LHP (mLHP) system is presented and optimal design of condenser is considered seeing that evaporators have been able to handle very high-heat fluxes with low-heat transfer resistances since most of the previous researchers focused on the evaporator of mLHP. The arrayed pins were designed and machined out on the bottom of condenser to enhance condensation heat transfer. The parameters of the arrayed pins, including layout, cross-section shape and area, were optimized by finite element analysis. Tests were carried out on the mLHP with a CPU thermal simulator using forced air convection condenser cooling to validate the optimization. The operation characteristics of the mLHP with optimal design parameters of condenser were investigated experimentally. The experimental results show that the mLHP can reject head load 200 W while maintaining the cooled object temperatures below 100 °C, and for a variable power applied to the evaporator, the system presents reliable startups and continuous operation.
Energy Technology Data Exchange (ETDEWEB)
Sato, S; Sugiyama, S; Nagata, K; Nanba, K; Shimono, M [Sumitomo Light Metal Industries Ltd., Tokyo (Japan)
1977-06-01
The corrosion resistance of titanium in sea water is extremely excellent, but titanium tubes are expensive, and the copper alloy tubes resistant in polluted sea water were developed, therefore they were not used practically. In 1970, ammonia attack was found on the copper alloy tubes in the air-cooled portion of condensers, and titanium tubes have been used as the countermeasure. As the result of the use, the galvanic attack on copper alloy tube plates with titanium tubes as cathode and the hydrogen absorption at titanium tube ends owing to excess electrolytic protection was observed, but the corrosion resistance of titanium tubes was perfect. These problems can be controlled by the application of proper electrolytic protection. The condensers with all titanium tubes adopted recently in USA are intended to realize perfectly no-leak condensers as the countermeasure to the corrosion in steam generators of PWR plants. Regarding large condensers of nowadays, three problems are pointed out, namely the vibration of condenser tubes, the method of joining tubes and tube plates, and the tubes of no coolant leak. These three problems in case of titanium tubes were studied, and the problem of the fouling of tubes was also examined. The intervals of supporting plates for titanium tubes should be narrowed. The joining of titanium tubes and titanium tube plates by welding is feasible and promising. The cleaning with sponge balls is effective to control fouling.
Condensation phenomena in a turbine blade passage
International Nuclear Information System (INIS)
Skillings, S.A.
1989-02-01
The mechanisms associated with the formation and growth of water droplets in the large low-pressure (LP) turbines used for electrical power generation are poorly understood and recent measurements have indicated that an unusually high loss is associated with the initial nucleation of these droplets. In order to gain an insight into the phenomena which arise in the turbine situation, some experiments were performed to investigate the behaviour of condensing steam flows in a blade passage. This study has revealed the fundamental significance of droplet nucleation in modifying the single-phase flow structure and results are presented which show the change in shock wave pattern when inlet superheat and outlet Mach number are varied. The trailing-edge shock wave structure appears considerably more robust towards variation of inlet superheat than purely one-dimensional considerations may suggest and the inadequacies of adopting a one-dimensional theory to analyse multi-dimensional condensing flows are demonstrated. Over a certain range of outlet Mach numbers an oscillating shock wave will establish in the throat region of the blade passage and this has been shown to interact strongly with droplet nucleation, resulting in a considerably increased mean droplet size. The possible implications of these results for turbine performance are also discussed. (author)
Aging evaluation of active components by using performance evaluation
International Nuclear Information System (INIS)
Jung, S. K.; Jin, T. E.; Kim, J. S.; Jung, I. S.; Kim, T. R.
2003-01-01
Risk analysis and performance evaluation methodology were applied to the aging evaluation of active components in the periodic safety review of Wolsung unit 1. We conclude that evaluation of performance is more effective to discriminate the aging degradation of active component than the evaluation of aging mechanism. It is essential to analyze the common cause failures of low performance components to evaluate the properness of present maintenance system. Past 10 years failure history is used for establishing the performance criteria. Past 2 years failure history is used for the evaluating the recent performance condition. We analyze the failure mode of the components to improve the maintenance system. Performance evaluation methodology is useful for the quantitative evaluation of aging degradation of active components. Analysis on the repeated failures can be useful for the feedback to maintenance plan and interval
Collapsing dynamics of attractive Bose-Einstein condensates
DEFF Research Database (Denmark)
Bergé, L.; Juul Rasmussen, J.
2002-01-01
The self-similar collapse of 3D and quasi-2D atom condensates with negative scattering length is examined. 3D condensates are shown to blow up following the scenario of weak collapse, for which 3-body recombination weakly dissipates the atoms. In contrast, 2D condensates undergo a strong collapse......, that absorbs a significant amount of particles. (C) 2002 Elsevier Science B.V. All rights reserved....
Dynamic Modeling of Steam Condenser and Design of PI Controller Based on Grey Wolf Optimizer
Directory of Open Access Journals (Sweden)
Shu-Xia Li
2015-01-01
Full Text Available Shell-and-tube condenser is a heat exchanger for cooling steam with high temperature and pressure, which is one of the main kinds of heat exchange equipment in thermal, nuclear, and marine power plant. Based on the lumped parameter modeling method, the dynamic mathematical model of the simplified steam condenser is established. Then, the pressure PI control system of steam condenser based on the Matlab/Simulink simulation platform is designed. In order to obtain better performance, a new metaheuristic intelligent algorithm, grey wolf optimizer (GWO, is used to realize the fine-tuning of PI controller parameters. On the other hand, the Z-N engineering tuning method, genetic algorithm, and particle swarm algorithm are adopted for tuning PI controller parameters and compared with GWO algorithm. Simulation results show that GWO algorithm has better control performance than other four algorithms.
Czech Academy of Sciences Publication Activity Database
Shamzhy, Mariya; Opanasenko, Maksym; Shvets, O. V.; Čejka, Jiří
2013-01-01
Roč. 1, AUG 2013 (2013), s. 1-11 ISSN 2296-2646 R&D Projects: GA ČR GBP106/12/G015 Grant - others:European Commission(XE) FP7/2007-2013, contract 228862 Institutional support: RVO:61388955 Keywords : condensation reactions * MOFs * zeolites Subject RIV: CF - Physical ; Theoretical Chemistry http://www.frontiersin.org/Journal/10.3389/fchem.2013.00011/abstract
Method and apparatus for controlled condensation isotope separation
International Nuclear Information System (INIS)
Sullivan, J.A.; Lee, J.T. Jr.; Kim, K.C.
1981-01-01
The invention provides a method for producing controlled homogeneous condensation of a molecular feed gas containing several isotopes. The feed gas flows at supersonic rates through an expansion nozzle under conditions at which the gas would normally condense. The gas is irradiated with laser radiation of a wavelength that selectively excites those molecules in the feed gas that contain a particular isotope, thus preventing their condensation. Condensate particles may be aerodynamically separated from the flowing gas stream
Yang, Xiaojian; Nath, Carissa; Doering, Alan; Goihl, John; Baidoo, Samuel Kofi
2017-01-01
The immense growth in global bioethanol production has greatly increased the supply of by-products such as whole stillage and condensed distiller's solubles, which could be potentially used for animal feeding. The objective of this study was to investigate effects of liquid feeding high levels of corn condensed distiller's solubles (CCDS) and whole stillage (CWS) on growth performance, carcass characteristics, belly firmness and meat sensory traits of pigs. A total of 256 pigs were blocked by sex and initial BW (13.5 ± 2.5 kg), and pens of pigs (8 pigs/pen) were randomly allocated to 1 of 4 dietary treatments (8 pens/treatment): 1) corn-soybean meal based diet as control, 2) 25% CWS + 5% CCDS, 3) 19.5% CWS + 10.5% CCDS, and 4) 19.5, 26, and 32.5% CWS + 10.5, 14, and 17.5% CCDS in phases 1 (28 d), 2 (38 d), and 3 (60 d), respectively. Inclusion levels of CCDS and CWS for Treatments 1, 2, and 3 were fixed during all the three phases of the experiment. Inclusion levels of CWS and CCDS were on 88% dry matter basis. The liquid feeding system delivered feed from the mixing tank to feed troughs by high-pressure air, had sensors inside feed troughs, and recorded daily feed intake on the basis of a reference feed intake curve. The pigs were fed 5 to 10 times per day with increasing frequency during the experiment. Control pigs had greater ( P 0.10) dressing percentage, loin muscle depth, and lean percentage were observed among the four treatments. Inclusion of CWS and CCDS reduced ( P 0.10) the overall like, flavor, tenderness and juiciness of loin chops when compared with the control group. In conclusion, our results indicate that including 30-50% of a mixture of whole stillage and condensed distiller's solubles in the growing-finishing diets may reduce growth performance, carcass weight and belly firmness, but does not affect pork sensory traits.
Bose-Einstein condensation and indirect excitons: a review.
Combescot, Monique; Combescot, Roland; Dubin, François
2017-06-01
We review recent progress on Bose-Einstein condensation (BEC) of semiconductor excitons. The first part deals with theory, the second part with experiments. This Review is written at a time where the problem of exciton Bose-Einstein condensation has just been revived by the understanding that the exciton condensate must be dark because the exciton ground state is not coupled to light. Here, we theoretically discuss this missed understanding before providing its experimental support through experiments that scrutinize indirect excitons made of spatially separated electrons and holes. The theoretical part first discusses condensation of elementary bosons. In particular, the necessary inhibition of condensate fragmentation by exchange interaction is stressed, before extending the discussion to interacting bosons with spin degrees of freedom. The theoretical part then considers composite bosons made of two fermions like semiconductor excitons. The spin structure of the excitons is detailed, with emphasis on the crucial fact that ground-state excitons are dark: indeed, this imposes the exciton Bose-Einstein condensate to be not coupled to light in the dilute regime. Condensate fragmentations are then reconsidered. In particular, it is shown that while at low density, the exciton condensate is fully dark, it acquires a bright component, coherent with the dark one, beyond a density threshold: in this regime, the exciton condensate is 'gray'. The experimental part first discusses optical creation of indirect excitons in quantum wells, and the detection of their photoluminescence. Exciton thermalisation is also addressed, as well as available approaches to estimate the exciton density. We then switch to specific experiments where indirect excitons form a macroscopic fragmented ring. We show that such ring provides efficient electrostatic trapping in the region of the fragments where an essentially-dark exciton Bose-Einstein condensate is formed at sub-Kelvin bath
Bahrami, Parviz A.
1996-01-01
Theoretical analysis and numerical computations are performed to set forth a new model of film condensation on a horizontal cylinder. The model is more general than the well-known Nusselt model of film condensation and is designed to encompass all essential features of the Nusselt model. It is shown that a single parameter, constructed explicitly and without specification of the cylinder wall temperature, determines the degree of departure from the Nusselt model, which assumes a known and uniform wall temperature. It is also known that the Nusselt model is reached for very small, as well as very large, values of this parameter. In both limiting cases the cylinder wall temperature assumes a uniform distribution and the Nusselt model is approached. The maximum deviations between the two models is rather small for cases which are representative of cylinder dimensions, materials and conditions encountered in practice.
Transition from condensation-induced counter-current flow to dispersed flow
International Nuclear Information System (INIS)
Gale, J.; Tiselj, I.
2004-01-01
Model of transition from the horizontally stratified condensation-induced counter-current flow to slug flow has been analyzed with computer code WAHA and compared to the experimental data obtained in the steamline of the PMK2 test facility of Hungarian Atomic Energy Institute. The experiment was performed in the steamline initially filled with hot vapor that was gradually flooded with cold liquid. Successful simulation of the condensation-induced water hammer that follows the transition, requires accurate description of the horizontally stratified and slug flow regimes and criteria for transition between both flow regimes. Current version of the WAHA code, not verified for the condensation induced type of the water hammer, predicts the water-hammer pressure peak that exceeds 600 bar, while the measured pressure is p m = 170 ± 50 bar. Sensitivity analysis of the inter-phase exchange terms and transition conditions, pointed to the most important closure relations for heat, mass and momentum transfer. The main conclusion of the analysis is large uncertainty of the simulations: minor modification of the crucial correlations can lead to a severe water-hammer in one case, or to the 'calm' transient without pressure peaks in the other case. Large uncertainty is observed in experiments. The same simulation was performed also with RELAP5 code. However, no water hammer was predicted. (author)
Hiratsuka, Tatsumasa; Tanaka, Hideki; Miyahara, Minoru T
2017-01-24
We find the rule of capillary condensation from the metastable state in nanoscale pores based on the transition state theory. The conventional thermodynamic theories cannot achieve it because the metastable capillary condensation inherently includes an activated process. We thus compute argon adsorption isotherms on cylindrical pore models and atomistic silica pore models mimicking the MCM-41 materials by the grand canonical Monte Carlo and the gauge cell Monte Carlo methods and evaluate the rate constant for the capillary condensation by the transition state theory. The results reveal that the rate drastically increases with a small increase in the chemical potential of the system, and the metastable capillary condensation occurs for any mesopores when the rate constant reaches a universal critical value. Furthermore, a careful comparison between experimental adsorption isotherms and the simulated ones on the atomistic silica pore models reveals that the rate constant of the real system also has a universal value. With this finding, we can successfully estimate the experimental capillary condensation pressure over a wide range of temperatures and pore sizes by simply applying the critical rate constant.
Exhaled Breath Condensate: Technical and Diagnostic Aspects
Directory of Open Access Journals (Sweden)
Efstathia M. Konstantinidi
2015-01-01
Full Text Available Purpose. The aim of this study was to evaluate the 30-year progress of research on exhaled breath condensate in a disease-based approach. Methods. We searched PubMed/Medline, ScienceDirect, and Google Scholar using the following keywords: exhaled breath condensate (EBC, biomarkers, pH, asthma, gastroesophageal reflux (GERD, smoking, COPD, lung cancer, NSCLC, mechanical ventilation, cystic fibrosis, pulmonary arterial hypertension (PAH, idiopathic pulmonary fibrosis, interstitial lung diseases, obstructive sleep apnea (OSA, and drugs. Results. We found 12600 related articles in total in Google Scholar, 1807 in ScienceDirect, and 1081 in PubMed/Medline, published from 1980 to October 2014. 228 original investigation and review articles were eligible. Conclusions. There is rapidly increasing number of innovative articles, covering all the areas of modern respiratory medicine and expanding EBC potential clinical applications to other fields of internal medicine. However, the majority of published papers represent the results of small-scale studies and thus current knowledge must be further evaluated in large cohorts. In regard to the potential clinical use of EBC-analysis, several limitations must be pointed out, including poor reproducibility of biomarkers and absence of large surveys towards determination of reference-normal values. In conclusion, contemporary EBC-analysis is an intriguing achievement, but still in early stage when it comes to its application in clinical practice.
Condenser Design for the Proposed AM600 NPP
Energy Technology Data Exchange (ETDEWEB)
Rahman, Md. Mizanur; Abdallah, Khaled Atya Ahmed; Field, Robert M. [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)
2015-10-15
The design goals are to make the condenser more robust and compact with a reduced component count. The AM600 condenser design also has new features as described below. Considering that the minimum heat sink temperature for potentially emergent nuclear countries is on the order of 21.deg. C or higher, a turbine design with a single low pressure rotor can be considered without sacrificing thermal efficiency. The condenser back pressure range for the considered markets is on the order of 2 to 3 in-HgA. With these boundary conditions, the AM600 condenser duty can be met with a single pressure zone design with a total of eight (8) titanium tube bundles (four (4) per pass) divided into four isolable sections. Due to the compact design (i.e., accepting exhaust from only one low pressure cylinder), both axial ends of the condenser are unobstructed and available for attachment of extended flash chambers, diverting inflows away from the tube bundles. The single shell design of this condenser then allows for an innovative design feature, namely the extended flash chambers. This permits the routing of dump, drain, vent, and bypass flows directly to these chambers, bypassing the condenser shell. Within the condenser shell, this design eliminates impingement plates, impingement boxes, and spargers. Failure of these components represents an ongoing source of condenser tube damage in operating nuclear units, requiring significant resources for outage inspections. The extended flash chamber approach also has a number of other advantages as delineated above.
Study on UF6 condensing receiving system improvement
International Nuclear Information System (INIS)
Zhang Zhenxing; Li Yingfeng; Li Zhenfeng; He Ping; Wang Yanping; Tian Yushan
2012-01-01
In order to improve receiving capacity of UF 6 condensing system, the pressure release mode is changed through modifying gas phase inlet of the first-grade condenser, thus pressure release time is reduced from 13.1 h to 8.1 h. Be- cause of improvement of utility condensers of the two product lines, both the flexibility of feeding nitrogen and the emergency capacity of condensers are improved greatly. And modification of fluid transferring and sampling system make the remains in system transfer flexibly. The practise shows that metal direct recovery rises to the extent, and capacity of the first-grade condensing receiving system improves 8.4%, which strongly guarantees fluorination production safely, continuously and stably run. (authors)
Computer-aided performance monitoring program at Diablo Canyon
International Nuclear Information System (INIS)
Nelson, T.; Glynn, R. III; Kessler, T.C.
1992-01-01
This paper describes the thermal performance monitoring program at Pacific Gas ampersand Electric Company's (PG ampersand E's) Diablo Canyon Nuclear Power Plant. The plant performance monitoring program at Diablo Canyon uses the THERMAC performance monitoring and analysis computer software provided by Expert-EASE Systems. THERMAC is used to collect performance data from the plant process computers, condition that data to adjust for measurement errors and missing data points, evaluate cycle and component-level performance, archive the data for trend analysis and generate performance reports. The current status of the program is that, after a fair amount of open-quotes tuningclose quotes of the basic open-quotes thermal kitclose quotes models provided with the initial THERMAC installation, we have successfully baselined both units to cycle isolation test data from previous reload cycles. Over the course of the past few months, we have accumulated enough data to generate meaningful performance trends and, as a result, have been able to use THERMAC to track a condenser fouling problem that was costing enough megawatts to attract corporate-level attention. Trends from THERMAC clearly related the megawatt loss to a steadily degrading condenser cleanliness factor and verified the subsequent gain in megawatts after the condenser was cleaned. In the future, we expect to rebaseline THERMAC to a beginning of cycle (BOC) data set and to use the program to help track feedwater nozzle fouling
One dimensional analysis model for condensation heat transfer in feed water heater
International Nuclear Information System (INIS)
Murase, Michio; Takamori, Kazuhide; Aihara, Tsuyoshi
1998-01-01
In order to simplify condensation heat transfer calculations for feed water heaters, one dimensional (1D) analyses were compared with three dimensional (3D) analyses. The results showed that average condensation heat transfer coefficients by 1D analyses with 1/2 rows of heat transfer tubes agreed with those by 3D analyses within 7%. Using the 1D analysis model, effects of the pitch of heat transfer tubes were evaluated. The results showed that the pitch did not affect much on heat transfer rates and that the size of heat transfer tube bundle could be decreased by a small pitch. (author)
Investigations in the problem of pion condensation using generator co-ordinate methods
International Nuclear Information System (INIS)
Chattopadhyay, P.; Providencia, J. da
1981-01-01
Pion condensation in neutron matter has been investigated using the generator coordinate methode and a simple p-wave interaction. The assumption of a condensed mode corresponding to one pion momentum (determined variationally) helps evaluate all the necessary matrix elements exactly. The technique of charge projection from a coherent state of negative pions is discussed, and calculations have been carried out for the cases of average charge conversation, charge projection before variation and for a charge conserving trial function. The ground-state energies and the lowest excitations of the system are obtained from numerical solutions of the Hill-Wheeler equation. (orig.)
Capillary Condensation in 8 nm Deep Channels.
Zhong, Junjie; Riordon, Jason; Zandavi, Seyed Hadi; Xu, Yi; Persad, Aaron H; Mostowfi, Farshid; Sinton, David
2018-02-01
Condensation on the nanoscale is essential to understand many natural and synthetic systems relevant to water, air, and energy. Despite its importance, the underlying physics of condensation initiation and propagation remain largely unknown at sub-10 nm, mainly due to the challenges of controlling and probing such small systems. Here we study the condensation of n-propane down to 8 nm confinement in a nanofluidic system, distinct from previous studies at ∼100 nm. The condensation initiates significantly earlier in the 8 nm channels, and it initiates from the entrance, in contrast to channels just 10 times larger. The condensate propagation is observed to be governed by two liquid-vapor interfaces with an interplay between film and bridging effects. We model the experimental results using classical theories and find good agreement, demonstrating that this 8 nm nonpolar fluid system can be treated as a continuum from a thermodynamic perspective, despite having only 10-20 molecular layers.
Radionuclide release calculations for selected severe accident scenarios. PWR, ice condenser design
Energy Technology Data Exchange (ETDEWEB)
Denning, R S; Gieseke, J A; Cybulskis, P; Lee, K W; Jordan, H; Curtis, L A; Kelly, R F; Kogan, V; Schumacher, P M
1986-07-01
This report presents results of analyses of the environmental releases of fission products (source terms) for severe accident scenarios in a pressurized water reactor with an ice-condenser containment. The analyses were performed to support the Severe Accident Risk Reduction/Risk Rebaselining Program (SARRP) which is being undertaken for the U.S. Nuclear Regulatory Commission by Sandia National Laboratories. In the SARRP program, risk estimates are being generated for a number of reference plant designs. The Sequoyah Plant has been used in this study as an example of a PWR ice-condenser plant. (author)
In-stack condensible particulate matter measurement and permitting issues
International Nuclear Information System (INIS)
Corio, L.A.; Sherwell, J.
1997-01-01
Based on the results of recent epidemiological studies and assessments of the causes of visibility degradation, EPA is proposing to regulate PM2.5 emissions. PM can be classified as either filterable or condensible PM. Condensible PM includes sulfates, such as sulfuric acid. Sulfates typically account for at least half of the total dry fine PM mass in the atmosphere. Power plant SO x -based emissions make a significant contribution to ambient fine PM levels in the eastern US. Although much of this mass is derived from secondary chemical reactions in the atmosphere, a portion of this sulfate is emitted directly from stacks as condensible PM. The potential condensible PM fraction associated with coal-burning boiler emissions is somewhat uncertain. The characterization of PM emissions from these sources has been, until recently, based on in-stack filterable PM measurements only. To determine the relative magnitude of condensible PM emissions and better understand condensible PM measurement issues, a review and analysis of actual EPA Method 202 results and state-developed hybrid condensible PM methods were conducted. A review of available Method 202 results for several coal-burning boilers showed that the condensible PM, on average, comprises 60% of the total PM10. A review of recent results for state-developed measurement methods for condensible PM for numerous coal-burning boilers indicated that condensible PM accounted for, on average, approximately 49% of total PM. Caution should be exercised in the use of these results because of the seemingly unresolved issue of artifact formation, which may bias the Method 202 and state-developed methods results on the high side. Condensible PM10 measurement results and issues, and potential ramifications of including condensible PM10 emissions in the PSD permit review process are discussed. Selected power plants in Maryland are discussed as examples
Cold Vacuum Drying facility condensate collection system design description
International Nuclear Information System (INIS)
PITKOFF, C.C.
1999-01-01
This document describes the Cold Vacuum Drying Facility (CVDF) condensate collection system (CCS). The function of the CCS is to collect cooling coil condensate from air-handling units in the CVDF and to isolate the condensate in collection tanks until the condensate is determined to be acceptable to drain to the effluent drain collection basin
Packaging, Transportation and Recycling of NPP Condenser Modules - 12262
Energy Technology Data Exchange (ETDEWEB)
Polley, G.M. [Perma-Fix Environmental Services, 575 Oak Ridge Turnpike, Oak Ridge, TN 37830 (United States)
2012-07-01
facility. If any of these issues were not adequately resolved prior to the start of the outage, costly delays would result and the re-start of the power plant could be impacted. The main focus of this project was to find successful methods for keeping this material out of the landfills and preserving the natural resources. In addition, this operation provided a significant cost savings to the public utility by minimizing landfill disposal. The onsite portion of the project has been completed without impact to the overall outage schedule. By the date of presentation, the majority of the waste from the condenser replacement project will have been processed and recycled. The goals for this project included helping Energy Northwest maintain the outage schedule, package and characterize waste compliantly, perform transportation activities in compliance with 49CFR (Ref-1), and minimize the waste disposal volume. During this condenser replacement project, over three millions pounds of waste was generated, packaged, characterized and transported without injury or incident. It is anticipated that 95% of the waste generated during this project will not require landfill disposal. All of the waste is scheduled to be processed, decontaminated and recycled by June of 2012. (authors)
National Research Council Canada - National Science Library
Ameel, Timothy
1999-01-01
.... Evaporators and condensers for meso-scale energy systems will most likely be constructed of microchannels due to the microfabrication constraints that limit most structures to two-dimensional planar geometries...
Condensation Analysis of Steam/Air Mixtures in Horizontal Tubes
International Nuclear Information System (INIS)
Lee, Kwon Yeong; Bae, Sung Won; Kim, Moo Hwan
2008-01-01
Perhaps the most common flow configuration in which a convective condensation occurs is a flow in a horizontal circular tube. This configuration is encountered in air-conditioning and refrigeration condensers as well as condensers in Rankine power cycles. Although a convective condensation is also sometimes contrived to occur in a co-current vertical downward flow, a horizontal flow is often preferred because the flow can be repeatedly passed through the heat exchanger core in a serpentine fashion without trapping liquid or vapor in the return bends. Many researchers have investigated a in-tube condensation for horizontal heat exchangers. However, almost all of them obtained tube section-averaged data without a noncondensable gas. Recently, Wu and Vierow have experimentally studied the condensation of steam in a horizontal heat exchanger with air present. In order to measure the condenser tube inner surface temperatures and to calculate the local heat fluxes, they developed an innovative thermocouple design that allowed for nonintrusive measurements. Here we developed a theoretical model using the heat and mass analogy to analyze a steam condensation with a noncondensable gas in horizontal tubes
Local condensate depletion at trap center under strong interactions
Yukalov, V. I.; Yukalova, E. P.
2018-04-01
Cold trapped Bose-condensed atoms, interacting via hard-sphere repulsive potentials are considered. Simple mean-field approximations show that the condensate distribution inside a harmonic trap always has the shape of a hump with the maximum condensate density occurring at the trap center. However, Monte Carlo simulations at high density and strong interactions display the condensate depletion at the trap center. The explanation of this effect of local condensate depletion at trap center is suggested in the frame of self-consistent theory of Bose-condensed systems. The depletion is shown to be due to the existence of the anomalous average that takes into account pair correlations and appears in systems with broken gauge symmetry.
Bose-Einstein condensation in real space
International Nuclear Information System (INIS)
Valencia, J.J.; Llano, M. de; Solis, M.A.
2004-01-01
We show how Bose-Einstein condensation (BEC) occurs not only in momentum space but also in coordinate (or real) space. Analogies between the isotherms of a van der Waals classical gas of extended (or finite-diameter) identical atoms and the point (or zero-diameter) particles of an ideal BE gas allow concluding that, in contrast with the classical case, the volume per particle vanishes in the pure BE condensate phase precisely because the boson diameters are zero. Thus a BE condensate forms in real space without exhibiting a liquid branch as does the classical gas. (Author)
Open string decoupling and tachyon condensation
International Nuclear Information System (INIS)
Chalmers, G.
2001-01-01
The amplitudes in perturbative open string theory are examined as functions of the tachyon condensate parameter. The boundary state formalism demonstrates the decoupling of the open string modes at the non-perturbative minima of the tachyon potential via a degeneration of open world-sheets and identifies an independence of the coupling constants g s and g YM at general values of the tachyon condensate. The closed sector is generated at the quantum level; it is also generated at the classical level through the condensation of the propagating open string modes on the D-brane degrees of freedom.
Dynamics of capillary condensation in aerogels.
Nomura, R; Miyashita, W; Yoneyama, K; Okuda, Y
2006-03-01
Dynamics of capillary condensation of liquid 4He in various density silica aerogels was investigated systematically. Interfaces were clearly visible when bulk liquid was rapidly sucked into the aerogel. Time evolution of the interface positions was consistent with the Washburn model and their effective pore radii were obtained. Condensation was a single step in a dense aerogel and two steps in a low density aerogel. Crossover between the two types of condensation was observed in an intermediate density aerogel. Variety of the dynamics may be the manifestation of the fractal nature of aerogels which had a wide range of distribution of pore radii.
Quark virtuality and QCD vacuum condensates
International Nuclear Information System (INIS)
Zhou Lijuan; Ma Weixing
2004-01-01
Based on the Dyson-Schwinger equations (DSEs) in the 'rainbow' approximation, the authors investigate the quark virtuality in the vacuum state and quantum-chromodynamics (QCD) vacuum condensates. In particular, authors calculate the local quark vacuum condensate and quark-gluon mixed condensates, and then the virtuality of quark. The calculated quark virtualities are λ u,d 2 =0.7 GeV 2 for u, d quarks, and λ s 2 =1.6 GeV 2 for s quark. The theoretical predictions are consistent with empirical values used in QCD sum rules, and also fit to lattice QCD predictions
Clark, Kevin B
2010-03-01
Fringe quantum biology theories often adopt the concept of Bose-Einstein condensation when explaining how consciousness, emotion, perception, learning, and reasoning emerge from operations of intact animal nervous systems and other computational media. However, controversial empirical evidence and mathematical formalism concerning decoherence rates of bioprocesses keep these frameworks from satisfactorily accounting for the physical nature of cognitive-like events. This study, inspired by the discovery that preferential attachment rules computed by complex technological networks obey Bose-Einstein statistics, is the first rigorous attempt to examine whether analogues of Bose-Einstein condensation precipitate learned decision making in live biological systems as bioenergetics optimization predicts. By exploiting the ciliate Spirostomum ambiguum's capacity to learn and store behavioral strategies advertising mating availability into heuristics of topologically invariant computational networks, three distinct phases of strategy use were found to map onto statistical distributions described by Bose-Einstein, Fermi-Dirac, and classical Maxwell-Boltzmann behavior. Ciliates that sensitized or habituated signaling patterns to emit brief periods of either deceptive 'harder-to-get' or altruistic 'easier-to-get' serial escape reactions began testing condensed on initially perceived fittest 'courting' solutions. When these ciliates switched from their first strategy choices, Bose-Einstein condensation of strategy use abruptly dissipated into a Maxwell-Boltzmann computational phase no longer dominated by a single fittest strategy. Recursive trial-and-error strategy searches annealed strategy use back into a condensed phase consistent with performance optimization. 'Social' decisions performed by ciliates showing no nonassociative learning were largely governed by Fermi-Dirac statistics, resulting in degenerate distributions of strategy choices. These findings corroborate
Efficient, Long-Life Biocidal Condenser, Phase I
National Aeronautics and Space Administration — Environmental control systems for manned lunar and planetary bases will require condensing heat exchangers to control humidity. Condensing surfaces must be...
21 CFR 573.200 - Condensed animal protein hydrolysate.
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Condensed animal protein hydrolysate. 573.200... ANIMALS Food Additive Listing § 573.200 Condensed animal protein hydrolysate. (a) Identity. The condensed animal protein hydrolysate is produced from the meat byproducts scraped from cured (salted) hides taken...
Theory of decoherence in Bose-Einstein condensate interferometry
Energy Technology Data Exchange (ETDEWEB)
Dalton, B J [ARC Centre for Quantum-Atom Optics and Centre for Atom Optics and Ultrafast Spectroscopy, Swinburne University of Technology, Melbourne, Victoria 3122 (Australia)
2007-05-15
A full treatment of decoherence and dephasing effects in BEC interferometry has been developed based on using quantum correlation functions for treating interferometric effects. The BEC is described via a phase space distribution functional of the Wigner type for the condensate modes and the positive P type for the non-condensate modes. Ito equations for stochastic condensate and non-condensate field functions replace the functional Fokker-Planck equation for the distribution functional and stochastic averages of field function products determine the quantum correlation functions.
Leak detection in turbo group condensers using helium
International Nuclear Information System (INIS)
Gomez Cores, C.; Lloret, J.
1997-01-01
This method allows a rapid location of leaks (small or not) in the pipelines of a turbo group condenser, before opening the condenser boxes and no need of stooping the turbo group operation. This operation can last two hours maximum depending on the volume of the box or semi box. The technique consists of injecting helium into the water side and detecting it in the steam side, in the outlet of not condensable gases of the ejector. In the same way, probable air inlet to the condenser can be proved (auxiliary systems, turbo group joints to the condenser, etc.) in order to improve the vacuum and/or reduce the quantity of oxygen dissolved in the water of the steam side. (author) [es
Test facility of the VVER-440 condensation-type pressure suppression system
International Nuclear Information System (INIS)
Wolff, H.; Arndt, S.
2004-01-01
Since the early nineties, GRS has supported regulatory authorities in Central and Eastern Europe in performing safety assessments of nuclear power plants. Especially studies of the condensation-type pressure suppression system of VVER-440/V-213-type plants have been important in this respect. Major steps in demonstrating complete functioning of the condensation-type pressure suppression system under accident conditions by experiments run in the Russian large scale test facility, BC V-213, have been completed in the past two years within the framework of various international experimental programs. The test results were used to validate specifically for power plants with VVER-400/V-213 reactors the COCOSYS GRS computer code, which is used in the safety assessments. The results of recalculations of the C02 EREC test, which simulates a break of a main steam pipe, demonstrate the present state of validation of COCOSYS for VVER condensation-type pressure suppression systems. (orig.) [de
The Dynamics of Aerosols in Condensational Scrubbers
DEFF Research Database (Denmark)
Johannessen, Jens Tue; Christensen, Jan A.; Simonsen, Ole
1997-01-01
A mathematical model for the simulation of the dynamics of aerosol change in condensational scrubbers and scrubbing condensers is proposed. The model is applicable for packed column gas/liquid contact when plug flow can be assumed. The model is compared with experimental data for particle removal...... for their estimation is proposed. The behaviour of scrubbers and condensers for some important technical applications is demonstrated by model simulations. (C) 1997 Elsevier Science Ltd....
International Nuclear Information System (INIS)
Park, Hyun Sik
1999-02-01
A database for laminar condensation heat transfer is constructed from the previous experimental data at various condensation conditions. Based on the database, the condensation models in the standard RELAP5/MOD3.2 code are assessed and improved. Two wall film condensation models, the default and the alternative, are used in RELAP5/MOD3.2. The default model of the laminar film condensation in RELAP5/MOD3.2 does not give any reliable predictions, and its alternative model always predicts higher values than the experimental data. Therefore, it is needed to develop a new correlation based on the experimental data of various operating ranges. A set of condensation experiments in the presence of noncondensable gas in a vertical tube of the passive containment cooling system of the CP-1300 are performed. The experimental results show that the heat transfer coefficients (HTCs) increase as the inlet air mass fraction decreases and the inlet saturated steam temperature decreases. However, the dependence of the inlet mixture Reynolds number on the HTC is small for the operating range. An empirical correlation is developed, and its predictions are compared with experimental data to show good agreement with the standard deviation of 22.3%. The experimental HTCs are also compared with the predictions from the default and the alternative models used in RELAP5/MOD3.2. The experimental apparatus is modeled with two wall-film condensation models in RELAP5/MOD3.2 and the empirical correlation, and simulations are performed for several subtests to be compared with the experimental results. Overall, the simulation results show that the default model of RELAP5/MOD3.2 underpredicts the HTCs, and the alternative model overpredicts them, while the empirical correlation predicts them well throughout the condensing tube. Both the nodalization study and the sensitivity study are also performed. The nodalization study shows that the variation of the node number does not change both modeling
International Nuclear Information System (INIS)
Kim, Kap; Kim, Hho Jung
1986-01-01
Some studies on direct-contact condensation in cocurrent stratified flow of steam and subcooled water were reviewed. Several approaches have been performed to develop the condensation heat transfer coefficient relationship. The local Nusselt number is correlated in terms of the local water Reynolds and Prandtl numbers as well as the steam Froude number. In addition, a turbulence-centered model, developed principally for gas absorption in several geometries, is modified by using calculated interfacial parameters for the turbulent velocity and length scales. These approaches result in a fairly good agreement with the data, whereas, the turbulence-centered model is here recommended since it is based on the turbulent properties which may be closely related to the condensation phenomena. (Author)
National Research Council Canada - National Science Library
Namani, Madhu; Geng, Hai-Ping; Lee, Andre; Blanski, Rusty L
2004-01-01
.... Experiments were performed using a nearly-monodisperse molecular weight polystyrene (PS) blended with varying amounts of two fully condensed POSS molecules surrounded with phenethyl and styrenyl groups...
Janson, Christer; Kalm-Stephens, Pia; Foucard, Tony; Norbäck, Dan; Alving, Kjell; Nordvall, S Lennart
2005-08-01
A positive relation between exhaled nitric oxide (NO) levels and allergen exposure has been found in some studies whereas there is less information on how non-allergen environmental factors influences exhaled NO. To study the relationship between exhaled NO levels in schoolchildren in relation to IgE sensitisation and allergenic and non-allergenic environmental factors. This study comprised 374 schoolchildren (13-14 years of age) who performed exhaled NO-measurements and skin prick tests. Exposure to allergens, respiratory infections, environmental tobacco smoke and home window pane condensation, the latter an indicator of high humidity and poor ventilation was evaluated through questionnaires. In IgE-sensitised children sensitisation to pets was a more important determinant of exhaled NO than sensitisation to pollen. Higher NO levels were found in cat-sensitised children with a cat or other furred pets at home compared to cat-sensitised children without pets (geometric mean, 24.0 vs. 13.9 ppb, P=0.03). Significantly higher exhaled NO levels were found in non-sensitised children that reported having a cold (5.7 vs. 3.8 ppb, P<0.001) or lived in homes with window pane condensation (7.1 vs. 4.4 ppb, P=0.01) than in non-sensitised children without a cold and window pane condensation, respectively. These associations were not found in children that were sensitised to inhalation allergens. Allergen exposure seems to be the most important determinant for exhaled NO levels in IgE-sensitised children whereas in non-sensitised children NO levels were associated with respiratory infections and home window pane condensation.
Targeted Functionalization of Nanoparticle Thin Films via Capillary Condensation
Gemici, Zekeriyya; Schwachulla, Patrick I.; Williamson, Erik H.; Rubner, Michael F.; Cohen, Robert E.
2009-01-01
Capillary condensation, an often undesired natural phenomenon in nanoporous materials, was used advantageously as a universal functionalization strategy in nanoparticle thin films assembled layer-by-layer. Judicious choice of nanoparticle (and therefore pore) size allowed targeted capillary condensation of chemical vapors of both hydrophilic and hydrophobic molecules across film thickness. Heterostructured thin films with modulated refractive index profiles produced in this manner exhibited broadband antireflection properties with an average reflectance over the visible region of the spectrum of only 0.4%. Capillary condensation was also used to modify surface chemistry and surface energy. Photosensitive capillary-condensates were UV-cross-linked in situ. Undesired adventitious condensation of humidity could be avoided by condensation of hydrophobic materials such as poly(dimethyl siloxane). © 2009 American Chemical Society.
Targeted Functionalization of Nanoparticle Thin Films via Capillary Condensation
Gemici, Zekeriyya
2009-03-11
Capillary condensation, an often undesired natural phenomenon in nanoporous materials, was used advantageously as a universal functionalization strategy in nanoparticle thin films assembled layer-by-layer. Judicious choice of nanoparticle (and therefore pore) size allowed targeted capillary condensation of chemical vapors of both hydrophilic and hydrophobic molecules across film thickness. Heterostructured thin films with modulated refractive index profiles produced in this manner exhibited broadband antireflection properties with an average reflectance over the visible region of the spectrum of only 0.4%. Capillary condensation was also used to modify surface chemistry and surface energy. Photosensitive capillary-condensates were UV-cross-linked in situ. Undesired adventitious condensation of humidity could be avoided by condensation of hydrophobic materials such as poly(dimethyl siloxane). © 2009 American Chemical Society.
Targeted functionalization of nanoparticle thin films via capillary condensation.
Gemici, Zekeriyya; Schwachulla, Patrick I; Williamson, Erik H; Rubner, Michael F; Cohen, Robert E
2009-03-01
Capillary condensation, an often undesired natural phenomenon in nanoporous materials, was used advantageously as a universal functionalization strategy in nanoparticle thin films assembled layer-by-layer. Judicious choice of nanoparticle (and therefore pore) size allowed targeted capillary condensation of chemical vapors of both hydrophilic and hydrophobic molecules across film thickness. Heterostructured thin films with modulated refractive index profiles produced in this manner exhibited broadband antireflection properties with an average reflectance over the visible region of the spectrum of only 0.4%. Capillary condensation was also used to modify surface chemistry and surface energy. Photosensitive capillary-condensates were UV-cross-linked in situ. Undesired adventitious condensation of humidity could be avoided by condensation of hydrophobic materials such as poly(dimethyl siloxane).
Investigations on the Steam Condensation in a Vertical Tube Geometry
Energy Technology Data Exchange (ETDEWEB)
Hwang, Ji-Hwan; Jerng, Dong-wook [Chung-Ang University, Seoul (Korea, Republic of)
2016-10-15
In case of accidents that threats containment integrity, such as Station Black Out (SBO), it is able to depressurize containment using exterior-surface condensation in presence of non-condensable gases, which is named as Passive Containment Cooling System (PCCS). It is very important to precisely predict heat removal capability PCCS, as it affects safety and economics. The effect of curvature is not yet experimentally and numerically studied. It is reported that the effect of curvature exists at single-phase condition, yet it is not studied that if it can applicable to two-phase condensation in presence of non-condensables. In this paper, various experimental data are collected to analyze if it is able to observe curvature effect. However, it is hard to analyze experimental data, as the geometry, experimental conditions and means of measurement differs. To check if the differences between experiments are curvature effect, each experiment is compared with CFD simulation result using a commercial CFD code, STAR-CCM+. In this paper, with correlations derived from prior studies, we found the existence of curvature effect under PCCS operating condition. However, it is unable to find out a clear curvature effect at experiment data as they scatter much. As a means of comparison reference between experiment, CFD code is used. From comparison between CFD and experiment, we could confirm the existence of curvature effect. However, measured heat transfer coefficients of Kawakubo’s experiment are relatively low, whereas Dehbi’s measurement data are relatively high. Also, considering that usage of eq. overly supplies steam to condensing shell region, heat transfer coefficients of Pan Tong’s measured relatively high, but not as much that of Dehbi’s. A further experimental identification is needed for evaluation. Currently, CFD code calculates the curvature effect. Overall trend versus air mass fraction is similar with average of experiment.
Condensation heat transfer for refrigerant-oil mixtures in microfin tube condenser
Energy Technology Data Exchange (ETDEWEB)
Cho, K N [Sungkyunkwan University, Seoul (Korea); Tae, S J [Sungkyunkwan University Graduate School, Seoul (Korea)
2000-04-01
Condensation heat transfer experiments for R-22 and R-407 C refrigerants mixed with mineral oil and POE oil respectively were performed in straight and U-bend sections of a microfin tube. Experimental parameters were an oil concentration from 0 to 5 %, a mass flux from 100 to 400 kg/m{sup 2}s and an inlet quality from 0.5 to 0.9. The enhancement factors for R-22 and R-407 C refrigerants at the first straight section decreased continuously as the oil concentration increased. They decreased rapidly as the mass maximum at the 90 deg. position. The heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33 % than the average heat transfer coefficients at the first straight section. (author). 10 refs., 6 figs., 1 tab.
Condensate growth in trapped Bose gates
Bijlsma, M.J.; Zaremba, E.; Stoof, H.T.C.
2000-01-01
We study the dynamics of condensate fromation in an inhomogeneous trapped Bose gas with a positive interatomic scattering length. We take into account both the nonequilibrium kinetics of the thermal cloud and the Hartree-Fock mean-field efects in the condensed and the noncondensed parts of the gas.
Condensate growth in trapped Bose gases
Bijlsma, M.J.; Zaremba, E.; Stoof, H.T.C.
2000-01-01
We study the dynamics of condensate formation in an inhomogeneous trapped Bose gas with a positive interatomic scattering length. We take into account both the nonequilibrium kinetics of the thermal cloud and the Hartree-Fock mean-field effects in the condensed and the noncondensed parts of the gas.
Park, Dae-Heon; Park, Jang-Woo
2011-01-01
Dew condensation on the leaf surface of greenhouse crops can promote diseases caused by fungus and bacteria, affecting the growth of the crops. In this paper, we present a WSN (Wireless Sensor Network)-based automatic monitoring system to prevent dew condensation in a greenhouse environment. The system is composed of sensor nodes for collecting data, base nodes for processing collected data, relay nodes for driving devices for adjusting the environment inside greenhouse and an environment server for data storage and processing. Using the Barenbrug formula for calculating the dew point on the leaves, this system is realized to prevent dew condensation phenomena on the crop's surface acting as an important element for prevention of diseases infections. We also constructed a physical model resembling the typical greenhouse in order to verify the performance of our system with regard to dew condensation control.