WorldWideScience

Sample records for condensate polishing plant

  1. Performance test of condensate polishing system for Qinshan Nuclear Power Plant

    International Nuclear Information System (INIS)

    You Zhaojin; Qian Shijun; Lu Ruiting

    1995-11-01

    The flow chart, resin performance and water quality specifications of the condensate polishing system for Qinshan Nuclear Power Plant (QNPP) are briefly described. The initial regeneration process and the following service of the condensate polishing system are introduced. And the ability to remove corrosion products and ionic impurities of the condensate polishing system are verified during start-up, normal power operation and condenser leakage of the plant. The result shows that the performance of condensate polishing system in QNPP can completely meet the design requirements. Especially during the start-up of the unit or the leakage of the condenser, despite the inlet water quality of the polishers is far worse than the specified standard, the outlet water quality is still controlled within the indexes. Finally, several existing problems, such as 'volume ratio between resins is not optimum' and 'the inert resin and anion resin can not be stratified completely', in the condensate polishing system are also discussed. (4 refs., 1 fig., 8 tabs.)

  2. Condensate polishing guidelines for PWR and BWR plants

    International Nuclear Information System (INIS)

    Robbins, P.; Crinigan, P.; Graham, B.; Kohlmann, R.; Crosby, C.; Seager, J.; Bosold, R.; Gillen, J.; Kristensen, J.; McKeen, A.; Jones, V.; Sawochka, S.; Siegwarth, D.; Keeling, D.; Polidoroff, T.; Morgan, D.; Rickertsen, D.; Dyson, A.; Mills, W.; Coleman, L.

    1993-03-01

    Under EPRI sponsorship, an industry committee, similar in form and operation to other guideline committees, was created to develop Condensate Polishing Guidelines for both PWR and BWR systems. The committee reviewed the available utility and water treatment industry experience on system design and performance and incorporated operational and state-of-the-art information into document. These guidelines help utilities to optimize present condensate polisher designs as well as be a resource for retrofits or new construction. These guidelines present information that has not previously been presented in any consensus industry document. The committee generated guidelines that cover both deep bed and powdered resin systems as an integral part of the chemistry of PWR and BWR plants. The guidelines are separated into sections that deal with the basis for condensate polishing, system design, resin design and application, data management and performance and management responsibilities

  3. Operating power plant experience with condensate polishing units in morpholine/ammonia-OH cycle

    International Nuclear Information System (INIS)

    Kumbhar, A.G.; Padmakumari, T.V.; Narasimhan, S.V.; Mathur, P.K.

    1995-01-01

    Impurity removal efficiency of condensate polisher plant (CPP) in ammonium cycle is poor. Cost considerations demand CPP operation in amine-OH cycle. With certain precautions such as higher regeneration levels, good regenerent quality, minimized cross contamination, continuous monitoring of influent and effluent and provision for 100% standby bed, it is possible to operate CPP beyond H-OH cycle while keeping the effluent impurities within the specified limits. This paper presents problem associated with the Madras Atomic Power Station (MAPS) CPP operation in morpholine-OH form and Korba Super Thermal Power Station (KSTPS) CPP in ammonia-OH form and suggested remedial measures. (author). 3 refs., 1 fig

  4. Condensate polisher application for PWR steam generator corrosion control

    International Nuclear Information System (INIS)

    Sawochka, S.G.; Leibovitz, J.; Siegwarth, D.P.; Pearl, W.L.

    1981-01-01

    The evolution of corrosion attack modes particularly in recirculating U-tube PWR steam generators has dictated a thorough review of the advantages and disadvantages of condensate polishing. Analytical modeling techniques to qualitatively predict crevice chemistry variations resulting from steam generator bulk water variations have allowed valuable insights to be developed. Modeling results complemented by steam generator and laboratory corrosion data will be employed to set condensate demineralizer effluent specifications consistent with control of steam generator corrosion. Laboratory and plant studies are being performed to demonstrate achievability of necessary effluent specifications. (author)

  5. Advanced ion exchange resins for PWR condensate polishing

    International Nuclear Information System (INIS)

    Hoffman, B.; Tsuzuki, S.

    2002-01-01

    The severe chemical and mechanical requirements of a pressurized water reactor (PWR) condensate polishing plant (CPP) present a major challenge to the design of ion exchange resins. This paper describes the development and initial operating experience of improved cation and anion exchange resins that were specifically designed to meet PWR CPP needs. Although this paper focuses specifically on the ion exchange resins and their role in plant performance, it is also recognized and acknowledged that excellent mechanical design and operation of the CPP system are equally essential to obtaining good results. (authors)

  6. The effects of fouled anion resin on condensate polishing plant performance at Dungeness B power station

    International Nuclear Information System (INIS)

    Bates, Chris

    2008-01-01

    The return to power, after an outage, at Dungeness B Power Station was delayed because of problems in achieving an in-specification feedwater acid conductivity. Dungeness B has a full flow cation/mixed bed condensate polishing plant (CPP). Investigations showed that the acid conductivity was produced by carbon dioxide and organic impurities both by-passing the CPP and slipping through it. Resin analysis showed that the anion resin had severely impaired sulfate removal kinetics. The paper covers the work done to try and identify the nature and source of the organics and their effect on the anion resin. One significant finding was that the carbonate removal kinetics were as impaired as those for sulfate removal; this had not been previously experienced in the CPP at any British Energy plant. (orig.)

  7. The regeneration test of the secondary loop condensate polishing mixed bed resin in Qinshan NPP

    International Nuclear Information System (INIS)

    Xu Meijing; Dong Liming

    1995-12-01

    There are four condensate polishing mixed beds in the water chemical treatment plant of Qinshan NPP. 2125 kg of D001-TR type cation exchange resin, 2000 kg of D201-TR type anion exchange resin, and 375 kg of S-TR type inert resin are filled into each mixed bed. The bed height of resin is 1.2 m and the volume is about 2.7 m 3 . In order to regenerate the exhausted resin out of the bed, the pre-designed condensate polishing mixed bed regeneration process was used to regenerate the first exhausted resin. After the resin was scrubbed and separated, cation resin and anion resin were respectively regenerated, rinsed to resume the exchange capability of the resin. The regenerated mixed bed is able to keep higher efficiency for condensate polishing. The outlet water quality and the resin service-life are able to meet the design requirements or more favorable than that. During the test, some main cations and anions in the blow-off water at each procedure were analyzed. The analyzed results were used to make pre-designed regeneration process better. The test results proved that pre-designed process is reasonable and effective. (6 refs., 6 figs., 7 tabs.)

  8. Condensate-polisher resin-leakage quantification and resin-transport studies

    International Nuclear Information System (INIS)

    Stauffer, C.C.; Doss, P.L.

    1983-04-01

    The objectives of this program were to: (1) determine the extent of resin leakage from current generation condensate polisher systems, both deep bed and powdered resin design, during cut-in, steady-state and flow transient operation, (2) analyze moisture separator drains and other secondary system samples for resin fragments and (3) document the level of organics in the secondary system. Resin leakage samples were obtained from nine-power stations that have either recirculating steam generators or once through steam generators. Secondary system samples were obtained from steam generator feedwater, recirculating steam generator blowdown and moisture separator drains. Analysis included ultraviolet light examination, SEM/EDX, resin quantification and infrared analysis. Data obtained from the various plants were compared and factors affecting resin leakage were summarized

  9. New ion exchange resin designs and regeneration procedures yield improved performance for various condensate polishing applications

    International Nuclear Information System (INIS)

    Najmy, S.W.

    2002-01-01

    Condensate polishing is an application with many different design and operational aspects. The past decade has brought new challenges for improved water quality with respect to both soluble and insoluble contaminants. Nonetheless, the endeavors to understand the compositional complexities of the ion exchange resin bead and the convoluted dynamics of ion exchange chemistry and chemical engineering mechanisms occurring within the mixed bed condensate polisher have brought new ideas and expectations for ion exchange resin in deep-bed condensate polishers than ever before. The new products and procedures presented here are a collaboration of a great deal of effort on the part of researchers, consultants, system engineers, station chemists, lab technicians and others. The studies discussed in this paper unequivocally demonstrate the merits of: 1. A specially designed cation resin to achieve greater than 95% insoluble iron removal efficiency, 2. A less-separable mixed resin for improved control of reactor water sulfate in BWR primary cycles, 3. Applying increased levels of regeneration chemicals and retrofitting the service vessels with re-mixing capability to improve the operation of deep-bed condensate polishers in PWR secondary cycles. (authors)

  10. Assessing operability of a novel polisher arrangement using MMS

    International Nuclear Information System (INIS)

    Shor, S.W.W.

    1987-01-01

    A condensate polisher is intended to remove both particulate matter and ionic material from the condensate. Condensate polishers have normally been placed directly in the condensate system downstream of the condensate pumps. This inline location has certain disadvantages. These disadvantages are discussed. Placing the polisher in a sidestream location, where water is removed from the condensate system, pumped through the polisher, and then returned to the condensate system provides a solution to these disadvantages. Several possible types of sidestream installations is described. This has a polisher taking unpolished condensate from one compartment from one compartment of a divided hotwell in a specially modified condenser and returning polished condensate to the other compartment. The polisher is supplied by its own dedicated pumps, which have a head requirement sufficient only to overcome the pressure drop through the polisher circuit at a flow rate of 110% of maximum condensate flow. This concept is very attractive but has not yet been tested even though it is being installed in several new units. A simulation was, therefore, performed using MMS to provide confidence that this particular sidestream polisher arrangement was operationally viable

  11. Crud removal with deep bed type condensate demineralizer in Tokai-2 BWR

    International Nuclear Information System (INIS)

    Abe, Ayumi; Takiguchi, Hideki; Numata, Kunio; Saito, Toshihiko

    1996-01-01

    The major objective and functions for the installation of the deep bed type condensate polishers in BWR power plants is to remove both ionic impurities caused by sea water leakage and suspended impurities called crud mainly consisting of metal oxides which are produced from metal corrosion. In considering the reduction of occupational radiation exposure level, it is extremely important to remove the crud effectively. In recent Japanese BWR power plants, condensate pre-filters with powdered ion exchange resins or with hollow fiber membrane have been installed to remove the crud at the upper stream of the deep bed polishers. In such plants, the crud removal is conventionally the secondary objective for the deep bed polishers. The Japan Atomic Power Company has introduced the small particle ion exchange resin and a soak regeneration method since April 1985, and then applied the low cross-linked resin since July 1995 at Tokai-2 Power Station, to improve the crud removal performance by using only deep bed type condensate demineralizer, and as a result condensate demineralizer outlet iron level has been kept below 1 ppb since 1991

  12. Active condensation of water by plants

    Directory of Open Access Journals (Sweden)

    Prokhorov Alexey Anatolievich

    2013-10-01

    Full Text Available This paper is devoted to some peculiarities of water condensation on the surface of plants . Arguments in support of the hypothesis that in decreasing temperature of leaves and shoots below the dew point, the plant can actively condense moisture from the air, increasing the duration of dewfall are presented. Evening dewfall on plant surfaces begins before starting the formation of fog. Morning condensation continues for some time after the air temperature exceeds the dew point . The phenomenon in question is found everywhere, but it is particularly important for plants in arid ecosystems.

  13. Condensate treatment and oxygen control in power plants

    International Nuclear Information System (INIS)

    Sakai, Toshiaki; Iida, Kei; Ohashi, Shinichi.

    1997-01-01

    In thermal and nuclear power stations, the steam that operated turbines is cooled and condensed with condensers. The condensate is heated again with boilers, nuclear reactors or steam generators, but if corrosion products or impurities are contained in the condensate, corrosion and scale formation occur in boilers and others. The filtration facility and the desalting facility for condensate are installed to remove impurities, but water quality control is different in thermal, BWR and PWR plants, therefore, the treatment facilities corresponding to respective condensates have been adopted. In order to reduce the amount of clud generation, the treatment of injecting a small quantity of oxygen into condensate has been adopted. In thermal power plants, all volatile treatment is carried out, in which corrosion is prevented by the addition of ammonia and hydrazine to boiler feedwater. The condensate filters of various types and the NH 4 type condensate desalter for thermal power plants are described. In BWR power plants, steam is generated in nuclear reactors, therefore, the addition of chemicals into water is never carried out, and high purity neutral water is used. In PWR power plants, the addition of chemicals to water is done in the primary system, and AVT is adopted in the secondary system. Also the condensate treatment facilities are different for both reactors. (K.I.)

  14. Titanium application to power plant condensers

    International Nuclear Information System (INIS)

    Itoh, H.

    1987-01-01

    Recently, the growth of operating performance and construction plan of titanium-tubed condensers in thermal and unclear power plants has been very impressive. High-quality, thinner welded titanium tubes used for cooling tubes, matching design specifications of condensers, have been stably supplied through mass production. It now can be said that various technical problems for titanium-tubed condensers have been solved, but data on operating performance in large-scale commercial plants are still scarce, and site-by-site information needs be exchanged more frequently and on a larger scale. Projects to replace existing condenser cooling tubes with those of corrosion-resistant titanium have been actively furthered, with the only remaining barrier to full employment being cost effectiveness. It is hoped that condenser and tube manufacturers will conduct more joint value analyses

  15. All welded titanium condenser adopted in atomic power plants

    International Nuclear Information System (INIS)

    Iwai, Nagao; Itabashi, Yukihiko

    1980-01-01

    Condensers in power plants are shell-and-tube type heat exchangers. Most condensers use seawater as a coolant. Their tube and tube Sheets have usually been made of brass, which resists corrosion but cannot completely prevent it; as a result, tubes sometimes corrode or erode, allowing seawater to leak into the turbine cycle. As is well known, titanium has almost complete corrosion resistance against seawater; for this reason titanium tubes have replaced brass ones in some condensers operating in Europe and the USA. Even in such condensers, though, the tube plates have still been made of brass, tightly fitted to the titanium tubes, and it has proved impossible to eliminate seawater leakage at the junctions between tubes and tube Sheets. In order to eliminate such leakage completely, the tube Sheets must be made of titanium too, and the tubes and plates must be welded together. However, the welding of titanium requires an extremely celan atmosphere, a condition very difficult to fulfill at power plant construction sites, and the use of whole welded titanium tube condensers has long been considered a practical impossibility. Such all-titanium welded condensers have now been successfully constructed and installed in two 600 MW fossil power plants and one 1100 MW nuclear power plant. This paper describes the techniques used, add in addition reviews the various materials that have been used in condenser tubes. (author)

  16. Study on corrosion of thermal power plant condenser tubes

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadi, Abdolreza Rashidi; Zhaam, Ali Akbar [Niroo Research Institute, end of Poonak Bakhtari blvd., Shahrak Ghods, Tehran (Iran)

    2004-07-01

    The aim of this investigation is to study kinds of corrosion mechanisms in thermal power plant condenser tubes. Condenser is a shell and tube heat exchanger in which cooling water flows through its tubes. While the steam from low pressure turbine passes within condenser tubes, it is condensed by cooling water. The exhausted steam from low pressure turbine is condensed on external surface of condenser tubes and heat is transferred to cooling water which flow into tubes. Tubes composition is usually copper-based alloys, stainless steel or titanium. Annual damages due to corrosion cause much cost for replacement and repairing metallic equipment and installations in electric power industry. Because of existence of different contaminants in water and steam cycle, condenser tubes surfaces are exposed to corrosion. Contaminants like oxygen, carbon dioxide, chloride ion and ammonia in water and steam cycle originate several damages such as pitting and crevice corrosion, erosion, galvanic attack, SCC, condensed corrosion, de-alloying in thermal power plant condenser. The paper first states how corrosion damage takes place in condensers and then introduces types of usual alloys used in condensers and also their corrosion behavior. In continuation, a brief explanation is presented about kinds of condenser failures due to corrosion. Then, causes and locations of different mechanisms of corrosion events on condenser tubes and effects of different parameters such as composition, temperature, chloride and sulfide ion concentration, pH, water velocity and biological precipitation are examined and finally protection methods are indicated. Also some photos of tubes specimens related to power plants are studied and described in each case of mentioned mechanisms. (authors)

  17. Use of steam condensate exchange process for recovery of deuterium from condensate of ammonia plant as adopted at Heavy Water Plant, Talcher (Paper No. 2.5)

    International Nuclear Information System (INIS)

    Saha, S.; Saha, P.

    1992-01-01

    This paper highlights the use of steam-condensate exchange system for recovery of deuterium from condensate of ammonia plant, which is adopted at Heavy Water Plant, Talcher. Deuterium concentration in the condensate leaving the steam-condensate exchange column can be brought down very close to the deuterium concentration in water thereby achieving practically complete deuterium recovery. (author). 2 tabs., 1 fig

  18. Optimal design of condenser volume in nuclear power plant

    International Nuclear Information System (INIS)

    Zheng Jing; Yan Changqi; Wang Jianjun

    2011-01-01

    The condenser is an important component in the nuclear power plant,whose dimension will influence the economy and the arrangement of the nuclear power plant.In this paper, the calculation model was established according to the design experience. The corresponding codes were also developed. The sensitivity of design parameters which influence the condenser Janume was analyzed. The present optimal design of the condenser, aiming at the volume minimization, was carried out with the self-developed complex-genetic algorithm. The results show that the reference condenser design is far from the best scheme. In addition, the results also verify the feasibility of the complex-genetic algorithm. Furthermore, the results of this paper can provide reference for the design of the condenser. (authors)

  19. Corrosion-related failures in power plant condensers. Final report

    International Nuclear Information System (INIS)

    Beavers, J.A.; Agrawal, A.K.; Berry, W.E.

    1980-08-01

    A survey of the literature has been conducted for the Electric Power Research Institute on corrosion failures in surface condensers. The survey was directed toward condenser failures in pressurized water reactor (PWR) power plants but includes pertinent literature related to fossil and to other nuclear power plants. It includes literature on reported service failures and on experimental studies that impact on these failures

  20. Air condensation plants

    International Nuclear Information System (INIS)

    Kelp, F.; Pohl, H.H.

    1978-01-01

    In this plant the steam is distributed by a ventilator from the bottom to symmetrically fixed, inclined cooling elements with tubes. The upper part of the current side of the cooling elements as well as the bottom part of the outflow side can be covered by cover plates via a control circuit. This way, part of the air amount is deviated and in case of unfavourable atmospheric conditions (cold) the air is heated. This heating is enough to prevent freezing of the condensate on the cooling tubes. (DG) [de

  1. Evaluation of condensate filtration technologies in fossil plants

    Energy Technology Data Exchange (ETDEWEB)

    D' Angelo, Philip J. [JoDan Technologies Ltd., Glen Mills, PA (United States)

    2009-09-15

    Long-term protection of electric power generating station boilers depends upon the quality of their feedwater chemistry with respect to the transport and deposition of corrosion products to the boilers from various corrosion sources in the plant's condensate and feedwater cycle. It is in the utility's best interests to expand their programs to include ways to reduce the transport of corrosion products, especially those that occur during plant start-ups. Condensate filtration is a strategy employed by some utilities with demonstrable results in minimizing corrosion product transport and achieving a return on their investment. This paper provides a comparative review of available condensate filtration technologies as well as performance data from fossil plants with the new large diameter high flow filtration systems. Additionally, the paper identifies critical parameters to consider before installation as well as the necessity for agreement between utilities and suppliers on common filtration terminology definitions, to insure an ''apple-to-apple'' basis when comparing a system or technology from more than one supplier. (orig.)

  2. Condensate treatment in BWR circuits by filter demineralizer units using powdered ion exchange resin at medium and high temperature

    International Nuclear Information System (INIS)

    De Martino, R.

    1983-01-01

    Considering the radiation build-up in some BWR reactors, we make a correlation between this phenomenon and the condensate purification system applied and the point of its utilization into the circuits. The application temperature of such a plant seems to have a very important role on the equilibria of metals contained in the reactor water and on the oxide composition. The efficiency of the condensate polishing system and the corrosion control are the most interesting objectives to achieve and to maintain, to control and regulate the physical and chemical process in the feedwater and in the reactor water. Up to date the technology owns major knowledge and a consistent know-how on using chemical products in order to increase the condensate polishing system efficiency. It is also considered a typical parallel case of a conventional power station and a secondary system of BWR units. (author)

  3. Condensing and water supplying systems in an atomic power plant

    International Nuclear Information System (INIS)

    Shinmura, Akira.

    1975-01-01

    Object: To reduce heat loss and eliminate accumulation of drain in water supplying and heating units in an atomic power plant by providing a direct contact type drain cooler between a gland-exhauster vapor condenser and a condensing and de-salting means, the drain from each water supplying and heating unit being collected in said cooler for heating the condensed water. Structure: Condensed water from a condenser is fed by a low pressure condensing pump through an air ejector and gland-exhauster vapor condenser to the direct-contact type drain cooler and is condensed in each water supply heater. Next, it is heated by drain fed through a drain level adjuster valve and an orifice and then forced by a medium pressure condenser pump into the condensing and de-salting means. It is then supplied by a high pressure condensing pump into the successive water supply heater. (Kamimura, M.)

  4. W-007H B Plant Process Condensate Treatment Facility. Revision 3

    International Nuclear Information System (INIS)

    Rippy, G.L.

    1995-01-01

    B Plant Process Condensate (BCP) liquid effluent stream is the condensed vapors originating from the operation of the B Plant low-level liquid waste concentration system. In the past, the BCP stream was discharged into the soil column under a compliance plan which expired January 1, 1987. Currently, the BCP stream is inactive, awaiting restart of the E-23-3 Concentrator. B Plant Steam Condensate (BCS) liquid effluent stream is the spent steam condensate used to supply heat to the E-23-3 Concentrator. The tube bundles in the E-23-3 Concentrator discharge to the BCS. In the past, the BCS stream was discharged into the soil column. Currently, the BCS stream is inactive. This project shall provide liquid effluent systems (BCP/BCS/BCE) capable of operating for a minimum of 20 years, which does not include the anticipated decontamination and decommissioning (D and D) period

  5. W-007H B Plant Process Condensate Treatment Facility. Revision 3

    Energy Technology Data Exchange (ETDEWEB)

    Rippy, G.L.

    1995-01-20

    B Plant Process Condensate (BCP) liquid effluent stream is the condensed vapors originating from the operation of the B Plant low-level liquid waste concentration system. In the past, the BCP stream was discharged into the soil column under a compliance plan which expired January 1, 1987. Currently, the BCP stream is inactive, awaiting restart of the E-23-3 Concentrator. B Plant Steam Condensate (BCS) liquid effluent stream is the spent steam condensate used to supply heat to the E-23-3 Concentrator. The tube bundles in the E-23-3 Concentrator discharge to the BCS. In the past, the BCS stream was discharged into the soil column. Currently, the BCS stream is inactive. This project shall provide liquid effluent systems (BCP/BCS/BCE) capable of operating for a minimum of 20 years, which does not include the anticipated decontamination and decommissioning (D and D) period.

  6. Ion leakage from mixed beds in condensate polishing plants

    International Nuclear Information System (INIS)

    Venderbosch, H.W.; Overman, L.J.; Snel, A.

    1977-01-01

    In view to the interest for theoretical and practical factors, which influence the ion slip of mixed bed filters, these facts were studied in detail. It proved to be necessary that the slip shall be subdivided into kinetic - and elution slip. The kinetic slip is depending e.g. on the electrolyte concentration of the influenct condensate, as well as on the period of contact, however it does not depend on the regeneration condition; the elution slip however depends clearly on the regeneration condition. Incomplete regeneration of the exchangers, a too low excess of regenerant, incomplete separation of cation - and anion exchanger, and the contact of an exchanger layer with the wrong regenerant in the separation zone, during the internal regeneration are raising the slip. With tests on mixed bed filters, which have been well regenerated, (less than 0.1% Na in the cation exchanger) and by using filters with normal regenerated exchangers, (approx. 10% Na in the cation exchanger) the quality of the effluent was compared with values, which were expected from calculations. In order to decrease the elution leakage, the contamination of the exchangers, especially at NH 4 OH - mixed bed filters, must be limited to a very low percentage. Several possibilities to obtain this, will be discussed in the lecture. Special attention will be paid to the internal regeneration procedure. KEMA has developed a method, the so-called partial regeneration method, in order to operate internal regenerated mixed bed filters, which have been designed for the HOH cycle, also in the ammonia form, without the occurence of an undue slip of sodium or chloride. Not only extended running periods and lower operating- and regeneration costs are of advantage, but also the reducing of salt- and ammonia containing sewage were achieved. (orig.) [de

  7. Materials in flue gas condensation plants; Materialval vid roekgaskondensering

    Energy Technology Data Exchange (ETDEWEB)

    Goldschmidt, Barbara; Nordling Magnus

    2003-02-01

    This project is the first part of a larger project. In the part reported here, materials for flue gas condensers have been investigated by contact with plant owners and suppliers and by a literature review of reported failures. If it is decided to continue with another part of the project, a number of materials will be long term tested on site. The project is complementary to an earlier project, which investigated the operating experiences from flue gas condensers in biomass fired cogeneration plants. In the project materials (steel and polymeric) suitable for long term testing in existing plants are discussed. It is proposed that testing in the second part of the project is made with material coupons in one plant fired with only biomass and one plant where biomass is co fired with other fuels. In the biomass fired plant a number of steel materials should be tested. In the co fired plant, with its harsher operating conditions, the same steel materials plus a number of polymeric materials should be tested. Materials suitable for testing are summarised in the report.

  8. Delisting strategy for the Hanford Site 242-A Evaporator PUREX Plant Condensate Treatment Facility

    International Nuclear Information System (INIS)

    1992-04-01

    This document describes the strategy that the US Department of Energy, Richland Field Office intends to use in preparing the delisting petition for the 242-A Evaporator/PUREX Plant Condensate Treatment Facility. Because the 242-A Evaporator/PUREX Plant Condensate Treatment Facility will not be operational until 1994, the delisting petition will be structured as an up-front petition based on the ''multiple waste treatment facility'' approach outline in the 1985 US Environmental Protection Agency's Petitions to Delist Hazardous Waste. The 242-A evaporator/PUREX Plant Condensate Treatment Facility effluent characterization data will not be available to support the delisting petition, because the delisting petition will be submitted to the US Environmental Protection Agency before start-up of the 242-A Evaporator/PUREX Plant Condensate Treatment Facility. Therefore, the delisting petition will be based on data collected during the pilot plant testing for the 242-A Evaporator/PUREX Plant Condensate Treatment Facility. This pilot plant testing will be conducted on synthetic waste. The composition of the synthetic waste will be based on: (1) constituents of regulatory concern, and (2) on process knowledge. The pilot plant testing will be performed to determine the removal efficiencies of the process equipment at concentrations greater than reasonably could be expected in the actual waste. This strategy document also describes the logic used to develop the synthetic waste, to develop the pilot plant testing program, and to prepare the delisting petition. This strategy document also described how full-scale operating data will be collected during initial operation of the 242-A Evaporator/PUREX Plant Condensate Treatment Facility to verify information presented in the delisting petition

  9. Failure of Titanium Condenser Tubes after 24 Years Power Plant Service

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Enemark, Allan; Hangaard, Anders

    2014-01-01

    The titanium condenser has been in operation for 24 years at Amager unit 3 power plant. In February 2012, the plant was contaminated by seawater due to a failed condenser tube and some tubes were plugged. A month later, the plant tripped again. Small leaks were found again and finally approx. 200...... a plant trip. In addition, small amounts of titanium hydride were revealed to be present in the tubes within the tubesheet indicating that the carbon steel tubesheet was corroding due to ingress of salt water. Although this was not the reason for the failure, it indicated the need for repair of the epoxy...

  10. Study of flue gas condensing for biofuel fired heat and power plants; Studie av roekgaskondensering foer biobraensleeldade kraftvaermeanlaeggningar

    Energy Technology Data Exchange (ETDEWEB)

    Axby, Fredrik; Gustafsson, J O; Nystroem, Johan; Johansson, Kent

    2000-11-01

    This report considers questions regarding flue gas condensing plants connected to bio-fuelled heat and power plants. The report consists of two parts, one where nine existing plants are described regarding technical issues and regarding the experience from the different plants. Part two is a theoretical study where heat balance calculations are made to show the technical and economical performance in different plant configurations and operating conditions. Initially the different parts in the flue gas condensing plant are described. Tube, plate and scrubber condensers are described briefly. The different types of humidifiers are also described, rotor, cross-stream plate heat exchanger and scrubber. Nine flue gas-condensing plants have been visited. The plants where chosen considering it should be bio-fuel fired plant primarily heat and power plants. Furthermore we tried to get a good dissemination considering plant configuration, supplier, geographical position, operating situation and plant size. The description of the different plants focuses on the flue gas condenser and the belonging components. The fuel, flue gas and condensate composition is described as well as which materials are used in the different parts of the plant. The experience from operating the plants and the reasons of why they decided to chose the actual condenser supplier are reported.

  11. Facility for processing the condensates from nuclear power plants (BWR and PWR)

    International Nuclear Information System (INIS)

    Lucker, Georges.

    1975-01-01

    A plant for the processing of the condensates from boiling water or pressurized water nuclear power plants is presented. A series of couples of units for the processing of the condensates through mixed beds of ion exchange resins simultaneously ensures the filtration and demineralization of the condensates. When the resins are saturated, each mixed bed is transferred into a unit of regeneration of said resins. Each processing unit is a sphere made of a stainless material, and provided with a plurality of air and water pipes allowing the admission and evacuation of the various elements to be successively controlled [fr

  12. Steam generator and condenser design of WWER-1000 type of nuclear power plant

    International Nuclear Information System (INIS)

    Zare Shahneh, Abolghasem.

    1995-03-01

    Design process of steam generator and condenser at Russian nuclear power plant type WWER-1000 is identified. The four chapter of the books are organized as nuclear power plant, types of steam generators specially horizontal steam generator, process of steam generator design and the description of condenser and its process design

  13. Development of high performance condensers for thermal and nuclear power plants

    International Nuclear Information System (INIS)

    Okouchi, Isao; Takahashi, Sankichi; Tomita, Akira.

    1980-01-01

    As the trend toward the large capacity of thermal and nuclear power plants advances, condensers also become large, and from the viewpoint of energy saving in whole plants, the maintenance of high performance and reliability is strongly desired. Hitachi Ltd. responded to this demand, and repeated the basic investigation with a model condenser on the selection of condenser cooling tubes and their arrangement. As the result, balanced downflow type tube arrangement was developed, which enables smooth steam flow and the improvement of condenser performance by forming the intense flow of turbine exhaust from the upper part of tube nest downward and making the steam flow in the lower part of tube nest into radial form toward air ejecting port. This tube arrangement has been applied to actual machines, and the excellent results have been obtained. In particular, the improvement of the degree of vacuum due to the reduction of steam flow loss is advantageous for increasing the power output of turbines. Thereupon, based on the basic experiment with various models of tube arrangement and the consideration on the operational results of actual machines using this tube arrangement, the features of this technique are reported. The basic construction of tube arrangement, the steam flow in tube nest, the vacuum in condensers, the supercooling of condensate, and actual balanced downflow type condensers are described. (Kako, I.)

  14. Radioactive recontamination on mechanically polished piping at Shimane-1 Nuclear Power Plant

    International Nuclear Information System (INIS)

    Umeda, K.; Komoto, I.; Imamura, K.; Kataoka, I.; Uchida, S.

    1998-01-01

    In a series of preventive maintenance tasks for an aging plant, recirculation pipes of Shimane-1 NPP have been replaced by newly fabricated type 316 NG stainless steel pipes. Suppression of shutdown dose rate caused by 60 Co recontamination on the newly replaced piping was one of the major concerns in the recirculation pipe replacement. In order to suppress the shutdown dose rate, control of the 60 Co deposition rate coefficient as well as 60 Co radioactivity in the reactor water are essential. The deposition rate coefficient depends on surface roughness. The coefficient is suppressed by reduction of the effective surface area of pipes through mechanical polishing. Then the inner surface of the pipes was polished mechanically to reduce roughness prior to application in the plant. After measuring and evaluating radioactive recontamination, it was estimated that deposited amounts of radioactive corrosion products on the pipe inner surface would reach the saturated value in a few years, and would not exceed the level before replacement unless water chemistry is degraded. (author)

  15. Computations of steam flow and heat transfer in nuclear power plant condensers

    International Nuclear Information System (INIS)

    Yuan, A.

    1997-01-01

    To improve performance of its PWR nuclear power plants, Electricite de France has developed a performance monitoring system that checks simultaneously the operation of the components of the secondary system. The performance monitoring system is based on a computational software CITER for steady state runs. A one-dimensional condenser model has been developed. Application of this code to a nuclear power plant condenser shows that predicted values in good agreement with the design values

  16. Modelling the thermodynamic performance of a concentrated solar power plant with a novel modular air-cooled condenser

    International Nuclear Information System (INIS)

    Moore, J.; Grimes, R.; Walsh, E.; O'Donovan, A.

    2014-01-01

    This paper aims at developing a novel air-cooled condenser for concentrated solar power plants. The condenser offers two significant advantages over the existing state-of-the-art. Firstly, it can be installed in a modular format where pre-assembled condenser modules reduce installation costs. Secondly, instead of using large fixed speed fans, smaller speed controlled fans are incorporated into the individual modules. This facility allows the operating point of the condenser to change and continuously maximise plant efficiency. A thorough experimental analysis was performed on a number of prototype condenser designs. This analysis investigated the validly and accuracy of correlations from literature in predicting the thermal and aerodynamic characteristics of different designs. These measurements were used to develop a thermodynamic model to predict the performance of a 50 MW CSP (Concentrated Solar Power) plant with various condenser designs installed. In order to compare different designs with respect to the specific plant capital cost, a techno-economic analysis was performed which identified the optimum size of each condenser. The results show that a single row plate finned tube design, a four row, and a two row circular finned tube design are all similar in terms of their techno-economic performance and offer significant savings over other designs. - Highlights: • A novel air cooled condenser for CSP (Concentrated Solar Power) applications is proposed. • A thorough experimental analysis of various condenser designs was performed. • Heat transfer and flow friction correlations validated for fan generated air flow. • A thermodynamic model to calculate CSP plant output is presented. • Results show the proposed condenser design can continually optimise plant output

  17. Exergy and exergoeconomic analysis of a petroleum refinery utilities plant using the condensing to power method

    Energy Technology Data Exchange (ETDEWEB)

    Mendes da Silva, Julio Augusto; Pellegrini, Luiz Felipe; Oliveira Junior, Silvio [Polytechnic School of the University of Sao Paulo, SP (Brazil)], e-mails: jams@usp.br, luiz.pellegrini@usp.br, soj@usp.br; Plaza, Claudio; Rucker, Claudio [Petrobras - Petroleo Brasileiro S.A., Rio de Janeiro, RJ (Brazil)], e-mails: claudioplaza@petrobras.com.br, rucker@petrobras.com.br

    2010-07-01

    In this paper a brief description of the main processes present in a modern high capacity refinery is done. The methodology used to evaluate, through exergy analysis, the performance of the refinery's utilities plant since it is responsible for a very considerable amount of the total exergy destruction in a refinery is presented. The utilities plant products: steam, electricity, shaft power and high pressure water had their exergy unit cost determined using exergoeconomic approach. A simple and effective method called condensing to power was used to define the product of the condensers in exergy basis. Using this method it is possible to define the product of the condenser without the use of negentropy concept nor the aggregation of condensers to the steam turbines. By using this new approach, the costs obtained for the plant's products are exactly the same costs obtained when the condenser is aggregated to the steam turbine but with the advantage that the information about the stream between condenser and the steam turbine is not lost and the condenser can be evaluated singly. The analysis shows that the equipment where attention and resources should be focused are the boilers followed by the gas turbine, that together, are responsible for 80% of total exergy destruction in the utilities plant. The total exergy efficiency found for the utilities plant studied is 35% while more than 280 MW of exergy is destroyed in the utilities processes. (author)

  18. Flue gas condensation in straw fired CHP plants; Roeggaskondensation i halmfyrede kraftvarmeanlaeg

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-06-15

    The high price of straw and a general demand for increased use of straw in power and heat production are expected to result in an increased need for efficient fuel utilization. The use of flue gas condensation in straw fired CHP plants can contribute to a higher exploitation of energy, and at the same time open of the possibility of utilization of wet (cheaper) fuels without energy loss. Furthermore flue gas condensation can contribute to the flue gas cleaning process through removal of HCl and SO{sub 2} as well as in particle cleaning in wet cleaning processes. With starting point in a straw fired CHP plant the technical and economic consequences of installation of a flue gas condensation system are investigated. Fuel exploitation and power/heat production distribution is included in the investigation. (BA)

  19. variability in condensed tannins and bitterness in spider plant ...

    African Journals Online (AJOL)

    ACSS

    Spider plant (Cleome gynandra L.) contributes considerably to the nutrition and medicines of communities in southern Africa. However, its utilisation is limited by its bitterness caused by condensed tannins. Unfortunately, processing options that reduce the bitterness also remove nutritionally and medicinally useful ...

  20. Measures against the adverse impact of natural wind on air-cooled condensers in power plant

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The natural wind plays disadvantageous roles in the operation of air-cooled steam condensers in power plant.It is of use to take various measures against the adverse effect of wind for the performance improvement of air-cooled condensers.Based on representative 2×600 MW direct air-cooled power plant,three ways that can arrange and optimize the flow field of cooling air thus enhance the heat transfer of air-cooled condensers were proposed.The physical and mathematical models of air-cooled condensers with various flow leading measures were presented and the flow and temperature fields of cooling air were obtained by CFD simulation.The back pressures of turbine were calculated for different measures on the basis of the heat transfer model of air-cooled condensers.The results show that the performance of air-cooled condensers is improved thus the back pressure of turbine is lowered to some extent by taking measures against the adverse impact of natural wind.

  1. Project C-018H, 242-A Evaporator/PUREX Plant Process Condensate Treatment Facility, functional design criteria. Revision 3

    International Nuclear Information System (INIS)

    Sullivan, N.

    1995-01-01

    This document provides the Functional Design Criteria (FDC) for Project C-018H, the 242-A Evaporator and Plutonium-Uranium Extraction (PUREX) Plant Condensate Treatment Facility (Also referred to as the 200 Area Effluent Treatment Facility [ETF]). The project will provide the facilities to treat and dispose of the 242-A Evaporator process condensate (PC), the Plutonium-Uranium Extraction (PUREX) Plant process condensate (PDD), and the PUREX Plant ammonia scrubber distillate (ASD)

  2. The numerical and experimental study of two passes power plant condenser

    Directory of Open Access Journals (Sweden)

    Rusowicz Artur

    2017-01-01

    Full Text Available The steam condenser is one of the most important element in whole power plant installation. Their proper design and operation makes a significant contribution to the efficiency of electricity production. The purpose of this article is to propose a two-dimensional mathematical model that allows modeling condenser work. In the model, the tube bundle is treated as a porous bed. The analysis has been subjected to a two passes power condenser with a capacity of 50 MW. The mathematical analysis was compared with the results of experimental studies. The average error between the model and the experiment for difference of cooling water temperatures was 5.15% and 11.60% for the first and second pass respectively. This allows to conclude that the proposed model is good enough to optimize future work of the condenser.

  3. Condensers

    International Nuclear Information System (INIS)

    Andrieux, M.B.

    1984-01-01

    Characteristics of the condenser cooling waters of various French 900 MW nuclear power plants. Design and description of various types of condensers: condensers feeded directly with river water, condensers feeded by cooling towers, condensers feeded with sea water of brackish water. Presentation of the main problems encountered with the brass bundles (ammoniacal corrosion, erosion of the peripheral tubes, vibrations of the tubes), with the titanium bundles, with the tubular plates, the tubes-tubular plates assemblies, the coatings of the condenser water chamber (sea water), the vapor by-pass and with the air inlet. Analysis of the in service performances such as condensation pressure, oxygen content and availability [fr

  4. Reduced program of inspection by induced currents for condenser of Embalse nuclear power plant

    International Nuclear Information System (INIS)

    Obrutsky, L.; Mendonca, H.

    1986-01-01

    In this work it's presented a reduced inspection in service program by the technique of induced currents to the turbine condenser of Embalse's Power Plant (Cordoba). The authors based its elaboration on the results obtained in the exam of a small number of tubes and on experience obtained through four inspections in the condensers of Atucha I Power Plant, through mathematical models of oxygen and ammoniac distribution in both Power Plants, and its experimental verification in the case of Atucha I. This program improves the quality of inspection thereby reducing time, equipment and personnel employed. (C.M.) [pt

  5. Condensation of steam

    International Nuclear Information System (INIS)

    Prisyazhniuk, V.A.

    2002-01-01

    An equation for nucleation kinetics in steam condensation has been derived, the equation taking into account the concurrent and independent functioning of two nucleation mechanisms: the homogeneous one and the heterogeneous one. The equation is a most general-purpose one and includes all the previously known condensation models as special cases. It is shown how the equation can be used in analyzing the process of steam condensation in the condenser of an industrial steam-turbine plant, and in working out new ways of raising the efficiency of the condenser, as well as of the steam-turbine plant as a whole. (orig.)

  6. Proceedings: Condenser technology conference

    International Nuclear Information System (INIS)

    Tsou, J.L.; Mussalli, Y.G.

    1991-08-01

    Seam surface condenser and associated systems performance strongly affects availability and heat rate in nuclear and fossil power plants. Thirty-six papers presented at a 1990 conference discuss research results, industry experience, and case histories of condenser problems and solutions. This report contains papers on life extension, performance improvement, corrosion and failure analysis, fouling prevention, and recommendation for future R ampersand D. The information represents recent work on condenser problems and solutions to improve the procurement, operation, and maintenance functions of power plant personnel. Several key points follow: A nuclear and a fossil power plant report show that replacing titanium tube bundles improves condenser availability and performance. One paper reports 10 years of experience with enhanced heat transfer tubes in utility condensers. The newly developed enhanced condenser tubes could further improve condensing heat transfer. A new resistance summation method improves the accuracy of condenser performance prediction, especially for stainless steel and titanium tubed condensers. Several papers describe improved condenser fouling monitoring techniques, including a review of zebra mussel issues

  7. Wild Edible Plants Used by the Polish Community in Misiones, Argentina.

    Science.gov (United States)

    Kujawska, Monika; Łuczaj, Łukasz

    We studied the cultural significance of wild edible plants for Eastern European migrants who settled in rural subtropical areas of South America. In 50 interviews with Polish migrants and their descendants in northern Misiones, Argentina, we recorded the use of 41 botanical species and two mushroom taxa. Different cultural significance indices were applied and sociodemographic factors such as gender, age and origin were addressed. Out of the ten most salient species, nine were fruits ( Eugenia uniflora , Eugenia involucrata , Rollinia salicifolia , Campomanesia xanthocarpa , Syagrus romanzoffiana , Allophylus edulis , Plinia peruviana , Plinia rivularis , Eugenia pyriformis ) and only one was a green vegetable ( Hypochaeris chillensis ). None of our informants reported famine foods, recreational teas or condiments. Men mentioned more wild edible species than women due to their more extensive knowledge of the forest plants growing further from settlements.

  8. Some hydrogen-control considerations for ice-condenser nuclear plants

    International Nuclear Information System (INIS)

    Hubbard, H.W.; Hammond, R.P.; Zivi, S.M.

    1981-02-01

    The proposal of the Tennessee Valley Authority (TVA) for coping with the problem of accident generated hydrogen gas in its Sequoyah ice-condenser plant was to put in place glow-plug igniters so that any hydrogen that is evolved during an accident could be burnt before accumulating into a dangerously large mass. Since it was desired to install these igniters in the Sequoyah and other plants as quickly as possible, the NRC asked the Lawrence Livermore National Laboratory (LLNL) to carry out some experiments on these igniters to delineate the region of their applicability

  9. Protected air-cooled condenser for the Clinch River Breeder Reactor Plant

    International Nuclear Information System (INIS)

    Louison, R.; Boardman, C.E.

    1981-01-01

    The long term residual heat removal for the Clinch River Breeder Reactor Plant (CRBRP) is accomplished through the use of three protected air-cooled condensers (PACC's) each rated at 15M/sub t/ following a normal or emergency shutdown of the reactor. Steam is condensed by forcing air over the finned and coiled condenser tubes located above the steam drums. The steam flow is by natural convection. It is drawn to the PACC tube bundle for the steam drum by the lower pressure region in the tube bundle created from the condensing action. The concept of the tube bundle employs a unique patented configuration which has been commercially available through CONSECO Inc. of Medfore, Wisconsin. The concept provides semi-parallel flow that minimizes subcooling and reduces steam/condensate flow instabilities that have been observed on other similar heat transfer equipment such as moisture separator reheaters (MSRS). The improved flow stability will reduce temperature cycling and associated mechanical fatigue. The PACC is being designed to operate during and following the design basis earthquake, depressurization from the design basis tornado and is housed in protective building enclosure which is also designed to withstand the above mentioned events

  10. Research observation: Hydrolyzable and condensed tannins in plants of the northwest

    Science.gov (United States)

    Gonzalez-Hernandez, M. P.; Karchesy, J.; Starkey, Edward E.

    2003-01-01

    Tannins are secondary metabolites that may influence feeding by mammals on plants. We analyzed hydrolyzable and condensed tannins in 30 plant species consumed by livestock and deer, as a preliminary attempt to study their possible implications on browsing and grazing in forest ecosystems. Heathers (Ericaceae) and plants of the Rose (Rosaceae) family had tannins, while forbs, grasses and shrubs other than the heathers did not show astringency properties. We found the highest tannin content of all the species in Rubus sp., with the highest value around 180 mg TAE/g dry weight in spring. Potentilla erecta, Alnus glutinosa and Quercus robur were next with 57 to 44 mg TAE/g dw. Total tannins in heathers ranged from 22 to 36 mg TAE/g dw. Levels of condensed tannins were higher than hydrolyzable for most of the species. Only Betula alba, Calluna vulgaris, Pteridium aquilinum and Vaccinium myrtillus had 100% hydrolyzable tannins. Tannin content of the species changed seasonally with highest values during the growing season, corresponding to late winter or early spring, depending on the species.

  11. First application of hollow fiber filter for PWR condensate polishing

    International Nuclear Information System (INIS)

    Tsuda, S.; Otoha, K.; Takiguchi, H.

    2002-01-01

    In Tsuruga Unit-2 (PWR 1160 MWe commenced commercial operation in 1987), current procedure for secondary system clean-up before start-up had prolonged outage time and had consumed a huge amount of de-ionized (DI) water. In addition, iron oxide in condensate had accelerated the degradation of condensate demineralizer (CD) resin. The corrosion product of iron could also influence the secondary side corrosion of steam generator (SG) tubing if it intruded into SG through CD. To solve these problems, Japan Atomic Power Company (JAPC) decided to introduce hollow fiber filter (HFF) type condensate filter into Tsuruga-2, as the first application to PWR in the world. Because of retro-fitted HFF in Tsuruga Unit-2, limitations for installation space and flow resistance in condensate system and cost reduction required new design for compact and low differential pressure system and for long life filter module. JAPC and ORGANO assessed methodologies to achieve these goals. An advanced HFF system, including a newly developed compact HFF module design, was installed at Tsuruga Unit-2 in 1997 based on the assessment. During the 5 years since the installation, the HFF system has provided excellent crud removal that enables to shorten the outage period and to reduce DI water consumption drastically. Stable differential pressure (dP) trend of the HFF system indicates an expected module life of more than 7 years, with backwash cleaning required only 2 or 3 times per year. In addition to providing the expected operating cost reduction and improved SG tube integrity, numerous additional benefits have resulted from the retrofit. (authors)

  12. Arrangement for the analysis of feed water- and condensate samples of power plants

    International Nuclear Information System (INIS)

    Mostofin, A.A.; Sorokina, N.S.

    1979-01-01

    The analysis of the feedwater- and condensate sample of condensation heat power plants and nuclear power plants results from the determination of the concentrations of salt and NH 3 . The sample is led through a multistep concentrator with evaporators. On the outlet of the evaporator are throttles for the outlet of the steam-gas-mixture. The throttle on the first evaporator is designed in a way that carbonic acid escapes from the sample, which is measured by a conductivity transmitter. A conductivity transmitter with an outlet signal that is proportional to the NH 3 content is also located on the throttle of the second evaporator. (RW) [de

  13. Extraction of deuterium from D-rich process condensate of ammonia plants

    Energy Technology Data Exchange (ETDEWEB)

    Haldar, T K; Kumar, Manoj; Ramamurty, C B [Heavy Water Board, Department of Atomic Energy, Mumbai (India)

    1994-06-01

    Heavy water plants based on ammonia-hydrogen exchange process receives feed synthesis gas from the adjacent fertilizer plants. The production capacity of such heavy water plants is directly proportional to the deuterium-content in feed synthesis gas. The chemical process involved in gas generation section of the fertilizer plant includes catalytic steam-reforming of natural gas/naphtha/fuel oil followed by shift conversion, alternatively coal classification followed by shift conversion. Effective extraction of deuterium from the deuterium-rich process condensate can boost the production capacity of heavy water plants considerably. This paper discusses various possible methods to achieve this objective. (author). 5 refs., 1 fig., 1 tab.

  14. Fischer's Plants in folk beliefs and customs: a previously unknown contribution to the ethnobotany of the Polish-Lithuanian-Belarusian borderland.

    Science.gov (United States)

    Kujawska, Monika; Klepacki, Piotr; Łuczaj, Łukasz

    2017-03-23

    Historical ethnobotanical studies are useful starting points for further diachronic analysis. The aim of this contribution is to present archival data from the Polish-Lithuanian-Belarusian borderland, which were collected by Adam Fischer, a Polish ethnographer from Lviv, in the 1930s. These data were originally gathered for publication in the first part of the Lexicon of Slavic beliefs and customs, dedicated to plant uses in traditional Slavonic culture. It was intended to be a joint international enterprise, but was never actually fulfilled. In this article we used information from historical Lithuania (the Great Duchy of Lithuania), nowadays a border region between Poland, Lithuania and Belarus. We applied cultural importance indices such as Use Value, Relative Importance value and Sørensen similarity coefficient, in order to compare our data with a western Ukraine data set from the same research framework. In total, 153 plant taxa were registered as used in peasant culture in the Polish-Lithuanian-Belarusian borderland in the 1930s. The species which achieved the highest Use Values were: Calendula officinalis, Cyanus segetum, Helichrysum arenarium, Betula sp., Prunella vulgaris, and Nuphar lutea or Lilium sp. The most salient use categories were medicinal, followed by food and home garden plants. The overall similarity to plants recorded in western Ukraine within the same project of Fischer's is quite low (46%), which may be explained by the partly different flora found in the regions, and a cultural discontinuity, revealed by the difference in species with the highest UV. Moreover, the field collaborators were different in the two regions and may have paid attention to different cultural spheres of use. The presented ethnobotanical data are a valuable contribution to the ethnobotany of Eastern Europe as a whole. In particular, the presented list of plants may be a rich source for future studies on the ethnobotany of the Polish diaspora in Lithuania, and

  15. Materials in flue gas condensation plants. Stage 2; Materialval vid roekgaskondensering. Etapp 2

    Energy Technology Data Exchange (ETDEWEB)

    Nordling, Magnus; Bergman, Gunnar; Baeck, Gustaf; Jacobsson, Karin; Pahverk, Helen; Roemhild, Stefanie

    2004-12-01

    The corrosion resistance of some metallic and polymeric materials has been investigated in the flue gas scrubbers/condensers in the power plants at Igelsta using waste wood and Brista using bio fuel in the boilers. The materials were exposed inside the inlet part of the condenser and inside the flue gas duct after the condenser. In Brista, the polymeric materials were also exposed to the hot flue gases inside the duct before the condenser. The temperature of the gases before and after the condenser in Brista was 140 deg C and 50-60 deg C, respectively. In Igelsta, the flue gas temperature after the condenser was 45 deg C. The metallic coupons in the condenser were located in the spray-zone, both in Igelsta and Brista. That was true also for the polymeric material in Brista. In both plants, the wash-solution had a pH of 7-8, a temperature of 30 deg C, and a low content of chloride. The metallic materials investigated were stainless steels of the following grades: 17-12-2.5, 2205, SAF2507 and 254SMO. The major part of the polymeric materials investigated consisted of FRP laminates, which were made with different combinations of resin type of surface veil and type of chopped strand mat (CSM). Laminates with a new type of vinyl ester resin, Atlac E-Nova FW 1045, a new type of a stress-corrosion-resistant glass-fibre called Arcotex, and two types of surface reinforcement of carbon fibre have been compared to laminates of common type. Laminates with a special reinforcement of the type 3-D fabric were also included as well as five polypropylene materials (PP) with varying degree of stabilisation, two glass-flake materials applied on carbon steel and a butyl rubber. The corrosion resistance of the materials was evaluated after seven a months exposure at the different positions in the plants. The stainless steel materials were evaluated with respect to uniform corrosion, pitting and crevice attack. The corrosion resistance of the polymeric materials was evaluated with

  16. Analytical model for power plant condenser for transients and off-normal operating conditions

    International Nuclear Information System (INIS)

    Thangamani, I.; Dutta, Anu; Chakraborty, G.; Ghosh, A.K.

    2006-11-01

    A computer code for power plant condenser dynamic analysis has been developed based on a lumped parameter approach considering time dependent mass and energy conservation equations over the control volumes for the shell side as well as tube side fluids. Effects of heat transfer on condenser structure and hot well level transients were considered in the analysis. Suitable heat transfer coefficient recommended by various standards and codes were employed. The code was used to analyze the condenser performance during steady state as well as transient (load rejection or turbine trip) conditions. The condenser performance is predicted in terms of condenser back pressure, shell side steam temperature and tube side coolant exit temperature with respect to time. As a part of parametric studies, the effect of change in tube side coolant flow rate and inlet temperature was also studied. The analysis predicted that up to 47% of rated coolant flow rate on the tube side (for design conditions), the steam dumping can be continued without condenser isolation. The paper describes the detailed methodology adopted for the condenser modeling and presents the results obtained from the different parametric studies and code validation. (author)

  17. Medicinal Plant Diversity and Inter-Cultural Interactions between Indigenous Guarani, Criollos and Polish Migrants in the Subtropics of Argentina

    Science.gov (United States)

    Kujawska, Monika; Hilgert, Norma I.; Keller, Héctor A.; Gil, Guillermo

    2017-01-01

    Numerous studies highlight the importance of phytotherapy for indigenous and non-indigenous people in different parts of the world. In this work we analyze the richness (number of species), diversity (plant identity and the number of illnesses for which it is used) and similarity of plant species and illnesses treated with them, in order to contribute new data and insight into the importance of plant medicines to the local medical systems of people living in Misiones province, in the subtropics of Argentina. Three sympatric groups were compared: Guarani Indians, Criollos (mestizos) and Polish migrants. Quantitative scrutiny was focused on both primary and secondary sources. The similarity and diversity of medicinal plants and uses between groups was calculated by applying the Sørensen quantitative coefficient and the Shannon-Wiener index, respectively. In order to identify the characteristic plant species used by each group, the Cultural Importance and Prevalence Value (CIPV) was calculated based on the species Indicator Value (IndVal), which combines a species relative abundance with its relative frequency of occurrence in the various groups, and modified according to the type of the analyzed data. The important finding is a great variation in the number of species used by the study groups. Altogether, 509 botanical species were registered: Guarani (397), Criollos (243) and Polish migrants (137). For all groups, the use of native medicinal plants prevailed. The Guarani appear to be the local experts in use of medicinal plants. There is the significant difference in the number of treated illnesses by each taxon among three groups. Criollos and Polish migrants exhibit the greatest similarity in illnesses treated with medicinal plants. These groups share a corpus of knowledge related to illness nosology, and have a symptomatic approach to illness treatment. The Guarani have an etiological approach to illness diagnosis and healing, which may be viewed as a barrier to

  18. Medicinal Plant Diversity and Inter-Cultural Interactions between Indigenous Guarani, Criollos and Polish Migrants in the Subtropics of Argentina.

    Science.gov (United States)

    Kujawska, Monika; Hilgert, Norma I; Keller, Héctor A; Gil, Guillermo

    2017-01-01

    Numerous studies highlight the importance of phytotherapy for indigenous and non-indigenous people in different parts of the world. In this work we analyze the richness (number of species), diversity (plant identity and the number of illnesses for which it is used) and similarity of plant species and illnesses treated with them, in order to contribute new data and insight into the importance of plant medicines to the local medical systems of people living in Misiones province, in the subtropics of Argentina. Three sympatric groups were compared: Guarani Indians, Criollos (mestizos) and Polish migrants. Quantitative scrutiny was focused on both primary and secondary sources. The similarity and diversity of medicinal plants and uses between groups was calculated by applying the Sørensen quantitative coefficient and the Shannon-Wiener index, respectively. In order to identify the characteristic plant species used by each group, the Cultural Importance and Prevalence Value (CIPV) was calculated based on the species Indicator Value (IndVal), which combines a species relative abundance with its relative frequency of occurrence in the various groups, and modified according to the type of the analyzed data. The important finding is a great variation in the number of species used by the study groups. Altogether, 509 botanical species were registered: Guarani (397), Criollos (243) and Polish migrants (137). For all groups, the use of native medicinal plants prevailed. The Guarani appear to be the local experts in use of medicinal plants. There is the significant difference in the number of treated illnesses by each taxon among three groups. Criollos and Polish migrants exhibit the greatest similarity in illnesses treated with medicinal plants. These groups share a corpus of knowledge related to illness nosology, and have a symptomatic approach to illness treatment. The Guarani have an etiological approach to illness diagnosis and healing, which may be viewed as a barrier to

  19. ALSTOM supercritical steam plants meet Polish market challenges and power generator's requirements

    Energy Technology Data Exchange (ETDEWEB)

    Twardowski, A.

    2007-07-01

    From the early 1990s the age and technical performance of most of the Polish power plants required urgent investment including rehabilitation and/or replacement. This was necessary as power demand was increasing continuously in parallel with country GDP growth. Poland's joining the EU in May 2005 caused additional obligations related to limitation of emissions by Poland as a country and specifically by the Polish power sector. The first big project focussed on replacement of old equipment, improvement of electricity production efficiency and reduction of environmental impact by rehabilitation of Units 1-6 in Turow power plant. This is briefly described in the presentation. The latest and the biggest project is the construction of a new supercritical, lignite fired 833 MW unit in BOT Belchatow PP awarded to ALSTOM in December 2004 as a full term key contract. In addition to a new power block the project included: a new desulfurisation plant; a complete close circle cooling system; a new electrical system control system, and water treatment system; a coal handling system connecting the new unit with lignite transportation system from the open mine to the existing plant; hydraulic ash and slug systems; and an electrostatic precipitator. The unit has reduced NOx emissions to the level below 200 mg/Nm{sup 3} thanks to low emission burners. Particulate emissions are below 30 mg/Nm{sup 3}, SOx emissions are below 220 mg/Nm{sup 3}; CO{sub 2} emissions are lowered and cooling water consumption reduced. Special noise protection systems and special design of some systems has greatly reduced the noise level. 2 photos.

  20. Lysenko affair and Polish botany.

    Science.gov (United States)

    Köhler, Piotr

    2011-01-01

    This article describes the slight impact of Lysenkoism upon Polish botany. I begin with an account of the development of plant genetics in Poland, as well as the attitude of scientists and the Polish intelligentsia toward Marxist philosophy prior to the World War II. Next I provide a short history of the introduction and demise of Lysenkoism in Polish science, with a focus on events in botany, in context with key events in Polish science from 1939 to 1958. The article outlines the little effects of Lysenkoism upon botanists and their research, as well as how botanists for the most part rejected what was often termed the "new biology." My paper shows that though Lysenko's theories received political support, and were actively promoted by a small circle of scientists and Communist party activists, they were never accepted by most botanists. Once the political climate in Poland altered after the events of 1956, Lysenko's theories were immediately abandoned.

  1. Research observation: Hydrolyzable and condensed tannins in plants of northwest Spain forests

    Science.gov (United States)

    Gonzalez-Hernandez, M. P.; Karchesy, J.; Starkey, E.E.

    2003-01-01

    Tannins are secondary metabolites that may influence feeding by mammals on plants. We analyzed hydrolyzable and condensed tannins in 30 plant species consumed by livestock and deer, as a preliminary attempt to study their possible implications on browsing and grazing in forest ecosystems. Heathers (Ericaceae) and plants of the Rose (Rosaceae) family had tannins, while forbs, grasses and shrubs other than the heathers did not show astringency properties. We found the highest tannin content of all the species in Rubus sp., with the highest value around 180 mg TAE/g dry weight in spring. Potentilla erecta, Alnus glutinosa and Quercus robur were next with 57 to 44 mg TAE/g dw. Total tannins in heathers ranged from 22 to 36 mg TAE/g dw. Levels of condensed tannins were higher than hydrolyzable for most of the species. Only Betula alba, Calluna vulgaris, Pteridium aquilinum and Vaccinium myrtillus had 100% hydrolyzable tannins. Tannin content of the species changed seasonally with highest values during the growing season, corresponding to late winter or early spring, depending on the species.

  2. Lifespan estimation of seal welded super stainless steels for water condenser of nuclear power plants

    Science.gov (United States)

    Kim, Young Sik; Park, Sujin; Chang, Hyun Young

    2014-01-01

    When sea water was used as cooling water for water condenser of nuclear power plants, commercial stainless steels can not be applied because chloride concentration exceeds 20,000 ppm. There are many opinions for the materials selection of tube and tube sheets of a condenser. This work reviewed the application guide line of stainless steels for sea-water facilities and the estimation equations of lifespan were proposed from the analyses of both field data for sea water condenser and experimental results of corrosion. Empirical equations for lifespan estimation were derived from the pit initiation time and re-tubing time of stainless steel tubing in sea water condenser of nuclear power plants. The lifespan of seal-welded super austenitic stainless steel tube/tube sheet was calculated from these equations. Critical pitting temperature of seal-welded PRE 50 grade super stainless steel was evaluated as 60 °C. Using the proposed equation in engineering aspect, tube pitting corrosion time of seal-welded tube/tube sheet was calculated as 69.8 years and re-tubing time was estimated as 82.0 years.

  3. Innovative coatings and surface modification of titanium for sea water condenser applications

    International Nuclear Information System (INIS)

    George, R.P.; Anandkumar, B.; Vanithakumari, S.C.; Kamachi Mudali, U.

    2016-01-01

    Effectiveness of cooling water systems in various power plants to maintain highest electrical energy output per tonne of fuel is important as part of good energy management. Cooling water systems of nuclear power plants using seawater for cooling comes under constant attack from the marine and sea water environment. Many metallic components and civil structures in the cooling water systems like bridges, intake wells, intake pipes, pump house wells, water boxes, condenser pipes are subjected to severe fouling and corrosion which limits the service life and availability of power plants. The experience with a coastal water cooled power plant at Kalpakkam (MAPS), India, showed that chlorination and screening control macrofouling to a great extend by controlling protozoans, invertebrates, algae and fungi. However 90% of marine bacteria are resistant to such control measures, and they cause microfouling of condenser pipes leading to poor heat transfer and microbially influenced corrosion (MIC) failures. Titanium is used as condenser for Indian nuclear power plants employing sea water cooling, including the PFBR at Kalpakkam. Though titanium is excellent with respect to corrosion behavior under sea water conditions, its biocompatible nature results in biofouling and MIC during service. Therefore innovative antifouling coatings and surface modification techniques for titanium condenser applications in seawater and marine environments are the need of the hour. Extensive investigations were carried out by different methods including nanostructuring of surfaces for making them antibacterial. The microroughness of titanium was produced by repeated pickling and polishing which by itself reduced microbial adhesion. To utilize photocatalytic activity for antibacterial property, anodization of titanium surfaces followed by heat treatment was adopted and this also has controlled microbial fouling. Electroless plating of nanofilm of copper-nickel alloy decreased biofouling of

  4. Condensing species from flue gas in Puertollano gasification power plant, Spain

    Energy Technology Data Exchange (ETDEWEB)

    Oriol Font; Xavier Querol; Felica Plana; Pilar Coca; Silvia Burgos; Francisco Garcia Pena [Institute of Earth Sciences ' Jaume Almera' , Barcelona (Spain). Environmental Geology

    2006-10-15

    The occurrence and distribution of trace elements (Pb, Zn, As, Ge, Cd, Tl, Bi, Sn, and also Ni, Fe and V) in condensates arising from coal gasification was investigated through the study of samples physically deposited on the gas cooling system from the Puertollano IGCC 335 MW power plant. These highly metal enriched samples are suitable for a comprehensive evaluation of the mode of occurrence of these elements in IGCC fly ash. Pb, Zn, Ge, and Fe sulfides, Ni-Fe arsenides, Ge and V oxides as well as traces of K chloride and Pb, Zn and Fe sulfates were determined as the major bearing phases for these elements. Three condensation zones were differentiated as function of the condensation temperatures and metal content: 1. Pb zone (520-750{sup o}C), characterized by the dominance of galena (70-90% of the main crystalline phases), and by the condensation of pyrrhotite and nickeline. 2. Ge-Zn-Pb zone (520-470{sup o}C), with sphalerite and wurzite being the dominant crystalline phases (over 40%), and Ge compounds, GeS{sub 2} and GeO{sub 2}, reaching 30% of the bulk condensates. 3. Zn zone (300-400{sup o}C), characterized by the dominance of Zn sulfides (over 85% of the main crystalline phases). The results obtained from these highly metalliferous condensates show similar forms of occurrence for the studied elements to those obtained in the bulk Puertollano IGCC fly ash (by using XAFS spectroscopy), where the contents of these elements are much lower. Furthermore, the sequential condensation of sulfides during coal gasification is similar to that from volcanic fumaroles, and may thus promote a better understanding of volcanic deposits. 23 refs., 7 figs., 5 tabs.

  5. Secondary water chemistry control practices and results of the Japanese PWR plants

    International Nuclear Information System (INIS)

    Maeda, Akihiro; Shoda, Yasuhiko; Ishihara, Nobuo; Murata, Kazutoyo; Fujiwara, Hiroyuki; Hayakawa, Hitoshi; Matsuda, Tadashi

    2012-09-01

    In Japan, since the start of the operation of the first PWR plant, Mihama Unit-1 in 1970, 24 PWR plants have been built by 2010, and all of them are in operation. Due to the plant-specific needs of management, and by flexibly incorporating the state-of-the-art insights into the design, the system configurations of the plants vary so many as 15 types. Meanwhile, the geographical feature of Japan makes all the Japanese PWR plants to have condensers cooled by sea water, and all the plants have a common system with a full-flow Condensate Polisher System (CPS). To prevent corrosion, continued improvements of the secondary water chemistry management has been performed like other countries, and one of the major features of the Japanese PWR plants is an enhanced provision for the condenser leakage. The water quality of SG (Steam Generator) has been significantly improved by the provision for the sea water leakage, in combination with other improvements in water chemistry management. Also in Japan, almost all of the treatments of the spent polisher resin and the wastewater are performed within the power plant sites. To facilitate the treatment of the waste water and the regeneration of the spent resins, either ammonia or ETA (Ethanol Amine) is selected as the pH adjustment agent for the secondary system water. Also at the ammonia treatment, high pH accomplishes the inhibition of the piping wall thinning and the lower iron transportation into SGs. In addition, the iron transported into the SG is removed by the chemical conditioning treatment called ASCA (Advanced Scale Conditioning Agent). This provides the effective recovery of the SG heat-transfer performance, and the improved SG support plate BEC (Broached Egg Crate) hole blockage rates. Basically in Japan, the secondary water chemistry management has been improved based on a single basic specification, for the variety of the plant configurations, with the plant-specific investigations and analyses. This paper summarizes

  6. Numerical modeling of counter-current condensation in a Black Liquor Gasification plant

    International Nuclear Information System (INIS)

    Risberg, Mikael; Gebart, Rikard

    2013-01-01

    Pressurized Entrained flow High Temperature Black Liquor Gasification is a novel technique to recover the inorganic chemicals and available energy in black liquor originating from kraft pulping. The gasifier has a direct quench that quickly cools the raw syngas when it leaves the hot reactor by spraying the gas with a water solution. As a result, the raw syngas becomes saturated with steam. Typically the gasifier operates at 30 bar which corresponds to a dew point of about 235 °C and a steam concentration in the saturated syngas that is about 3 times higher than the total concentration of the other species in the syngas. After the quench cooler the syngas is passed through a counter-current condenser where the raw syngas is cooled and most of the steam is condensed. The condenser consists of several vertical tubes where reflux condensation occurs inside the tubes due to water cooling of the tubes on the shell-side. A large part of the condensation takes place inside the tubes on the wall and results in a counterflow of water driven by gravity through the counter current condenser. In this study a computational fluid dynamics model is developed for the two-phase fluid flow on the tube-side of the condenser and for the single phase flow of the shell-side. The two-phase flow was treated using an Euler–Euler formulation with closure correlations for heat flux, condensation rate and pressure drop inside the tubes. The single-phase model for the shell side uses closure correlations for the heat flux and pressure drop. Predictions of the model are compared with results from experimental measurements in a condenser used in a 3 MW Black Liquor Gasification development plant. The results are in good agreement with the limited experimental data that has been collected in the experimental gasifier. However, more validation data is necessary before a definite conclusion can be drawn about the predictive capability of the code. -- Highlights: • A multi-phase model for a

  7. Direct anthelmintic effects of condensed tannins from diverse plant sources against Ascaris suum.

    Directory of Open Access Journals (Sweden)

    Andrew R Williams

    Full Text Available Ascaris suum is one of the most prevalent nematode parasites in pigs and causes significant economic losses, and also serves as a good model for A. lumbricoides, the large roundworm of humans that is ubiquitous in developing countries and causes malnutrition, stunted growth and compromises immunity to other pathogens. New treatment options for Ascaris infections are urgently needed, to reduce reliance on the limited number of synthetic anthelmintic drugs. In areas where Ascaris infections are common, ethno-pharmacological practices such as treatment with natural plant extracts are still widely employed. However, scientific validation of these practices and identification of the active compounds are lacking, although observed effects are often ascribed to plant secondary metabolites such as tannins. Here, we extracted, purified and characterised a wide range of condensed tannins from diverse plant sources and investigated anthelmintic effects against A. suum in vitro. We show that condensed tannins can have potent, direct anthelmintic effects against A. suum, as evidenced by reduced migratory ability of newly hatched third-stage larvae and reduced motility and survival of fourth-stage larvae recovered from pigs. Transmission electron microscopy showed that CT caused significant damage to the cuticle and digestive tissues of the larvae. Furthermore, we provide evidence that the strength of the anthelmintic effect is related to the polymer size of the tannin molecule. Moreover, the identity of the monomeric structural units of tannin polymers may also have an influence as gallocatechin and epigallocatechin monomers exerted significant anthelmintic activity whereas catechin and epicatechin monomers did not. Therefore, our results clearly document direct anthelmintic effects of condensed tannins against Ascaris and encourage further in vivo investigation to determine optimal strategies for the use of these plant compounds for the prevention and

  8. Emissions from the Polish power industry

    International Nuclear Information System (INIS)

    Uliasz-Bochenczyk, Alicja; Mokrzycki, Eugeniusz

    2007-01-01

    Poland is a country where power and heat energy production is based on conventional fuel combustion, above all hard coal and lignite. In power plants and combined heat and power plants, fossil fuel combustion results in emitting to the atmosphere first of all SO 2 , NO x , CO, particulate matter, greenhouse gases for instance N 2 O and CO 2 . For many years the Polish power industry has tried to reduce the emission of air contaminants to the atmosphere. The reduction is feasible on account of various methods of emission reduction, which have been advanced and applied for many years. The paper presents conventional fuels used in the Polish professional power industry, as well as the principal emission types occurring there for the last 10 years and the undertaken reduction measures

  9. The reduction of atmospheric emissions after the implementation of first Polish nuclear power plant

    Science.gov (United States)

    Cholewiński, Maciej

    2018-04-01

    In this work the environmental benefits in the atmospheric emissions after the implementation of 3,000 MW nuclear power plants were assessed and presented. To determine the quantity of avoided emissions of CO2, NOx, SO2 and Hg compounds, harmonised stoichiometric combustion model dedicated to solid fuel fired power plant was created. To increase the credibility of the studies, future strict emission standards (Directive 2010/75/EU, BAT documents for LCP) were included as well. In conducted studies, representative samples of 3 different Polish solid fuels were examined (by comprehensive proximate and ultimate analysis) and used in assessment. It was proven that by the replacement of thermal solid fuel power plant by nuclear unit (with annual production rate of 22.4 TWh net) up to 16.4 million tonnes of lignite, 8.9 million tonnes of hard coal or 13.1 million tonnes of solid biomass can be saved. Further, for the case of lignite, the emission, at least, of 21.29 million tonnes of CO2 (6.9% of all Polish emission in 2015), 1,610 tonnes of dust (0.4%), 16,102 tonnes of NOx (2.2%), 16,102 tonnes of SO2 (2.0%) and 564 kg of mercury (5.9%) can be avoided. For selected hard coal, calculated emission savings were equal to 17.60 million tonnes of CO2 (5.7%), 1,357 tonnes of dust (0.4%), 13,566 tonnes of NOx (1.9%), 13,566 tonnes of SO2 (1.7%), 271 kg of mercury (2.9%), and for biomass - equal to 20.04 million tonnes of CO2 (6.5%), 1,471 tonnes of dust (0.4%), 14,712 tonnes of NOx (2.0%), 14,712 tonnes of SO2 (1.8%) and 294 kg of mercury (3.1%).

  10. The reduction of atmospheric emissions after the implementation of first Polish nuclear power plant

    Directory of Open Access Journals (Sweden)

    Cholewiński Maciej

    2018-01-01

    Full Text Available In this work the environmental benefits in the atmospheric emissions after the implementation of 3,000 MW nuclear power plants were assessed and presented. To determine the quantity of avoided emissions of CO2, NOx, SO2 and Hg compounds, harmonised stoichiometric combustion model dedicated to solid fuel fired power plant was created. To increase the credibility of the studies, future strict emission standards (Directive 2010/75/EU, BAT documents for LCP were included as well. In conducted studies, representative samples of 3 different Polish solid fuels were examined (by comprehensive proximate and ultimate analysis and used in assessment. It was proven that by the replacement of thermal solid fuel power plant by nuclear unit (with annual production rate of 22.4 TWh net up to 16.4 million tonnes of lignite, 8.9 million tonnes of hard coal or 13.1 million tonnes of solid biomass can be saved. Further, for the case of lignite, the emission, at least, of 21.29 million tonnes of CO2 (6.9% of all Polish emission in 2015, 1,610 tonnes of dust (0.4%, 16,102 tonnes of NOx (2.2%, 16,102 tonnes of SO2 (2.0% and 564 kg of mercury (5.9% can be avoided. For selected hard coal, calculated emission savings were equal to 17.60 million tonnes of CO2 (5.7%, 1,357 tonnes of dust (0.4%, 13,566 tonnes of NOx (1.9%, 13,566 tonnes of SO2 (1.7%, 271 kg of mercury (2.9%, and for biomass - equal to 20.04 million tonnes of CO2 (6.5%, 1,471 tonnes of dust (0.4%, 14,712 tonnes of NOx (2.0%, 14,712 tonnes of SO2 (1.8% and 294 kg of mercury (3.1%.

  11. Dynamic analysis of the condensate feedwater system in boiling water reactor plants

    International Nuclear Information System (INIS)

    Tanji, J.; Omori, T.

    1982-01-01

    The computer code, CONFAC, has been developed for dynamic analysis of the condensate feedwater system in boiling water reactor plants. This code simulates the hydrodynamics in the piping system, the pump dynamics, and the feedwater controller in order to clarify the system transient characteristics in such cases as pump trip incidents. Code verification was performed by comparison between analytical results and actual plant operational data. Satisfactory agreement was obtained. With the code, appropriate pump start/stop interlocks were estimated for preventing pump cavitation in pump trip incidents

  12. Plant-wide control of coupled distillation columns with partial condensers

    International Nuclear Information System (INIS)

    Ebrahimzadeh, Edris; Baxter, Larry L.

    2016-01-01

    Highlights: • Extractive distillation system for CO_2–ethane azeotrope separation. • Control of distillation column systems that have interconnected partial condenser and total condenser columns. • Single-end temperature control of distillation columns. • Aspen Dynamics tools applied for rigorous steady-state and dynamic simulations. - Abstract: Conventional distillation control processes use vapor distillate flowrate to control column pressure and condenser heat removal to control the reflux drum level. These intuitive control systems work well for isolated columns or columns with total condensers. However, these controls are not effective when columns with partial condensers occur in series. The pressure and reflux drum level interact in such systems in ways that defeat conventional control systems, rendering them unable to maintain product purities in the presence of large feed flowrate and composition disturbances. This investigation documents a plant-wide control structure that can address this issue by controlling pressure through reflux heat removal rate and reflux drum level by reflux flow rate. This control system demonstrates its capability to handle large disturbances in throughput and feed composition through a series of Aspen simulations. This alternative system is no more complicated than the conventional system and should work on distillation columns of nearly all designs, not just the coupled partial condenser designs for which it is essential. Common natural gas processing provides a specific example of this alternative control system. Natural gas commonly includes high concentrations of CO_2 that must be removed prior to pipeline or LNG distribution. The existence of a minimum-boiling temperature azeotrope between ethane, virtually always present in natural gas, and carbon dioxide complicates the separation of CO_2 from the hydrocarbons. This separation commonly employs extractive distillation with high-molecular-weight hydrocarbons. Our

  13. Optimal design of condenser weight

    International Nuclear Information System (INIS)

    Zheng Jing; Yan Changqi; Wang Jianjun

    2011-01-01

    The condenser is an important component in nuclear power plants, which dimension and weight will effect the economical performance and the arrangement of the nuclear power plants. In this paper, the calculation model is established according to the design experience. The corresponding codes are also developed, and the sensitivity of design parameters which influence the condenser weight is analyzed. The present design optimization of the condenser, taking the weight minimization as the objective, is carried out with the self-developed complex-genetic algorithm. The results show that the reference condenser design is far from the best scheme, and also verify the feasibility of the complex-genetic algorithm. (authors)

  14. Boilers, evaporators, and condensers

    International Nuclear Information System (INIS)

    Kakac, S.

    1991-01-01

    This book reports on the boilers, evaporators and condensers that are used in power plants including nuclear power plants. Topics included are forced convection for single-phase side heat exchangers, heat exchanger fouling, industrial heat exchanger design, fossil-fuel-fired boilers, once through boilers, thermodynamic designs of fossil fuel-first boilers, evaporators and condensers in refrigeration and air conditioning systems (with respect to reducing CFC's) and nuclear steam generators

  15. Production of rare earth polishing powders in Russia

    International Nuclear Information System (INIS)

    Kosynkin, V.D.; Ivanov, E.N.; Kotrekhov, V.A.; Shtutza, M.G.; Grabko, A.I.

    1998-01-01

    Full text: Russia is a potent producer of polishing powders made of rare earth material presented as an extensive and well developed base. Considering the reserves, the facilities predisposition and the polishing agent (cerium dioxide) content the chief mineral source is loparite, apatite and monazite. The production of rare earth polishing powders is based on specially developed continuous technological processes, corrosion-proof equipment, ensuring a high and stable production quality. A special attention is paid to the radiation safety of the powders. The initial material for the rare earth polishing powders based on loparite is the fusion cake of rare earth chlorides obtained at that mineral chlorination. The technology of the polishing powder production from the REE fusion cake includes the following stages: dissolution of the REE fusion cake chlorides; - thorough cleaning of the REE fusion cake chlorides from radioactive and non-rare-earth impurities; chemical precipitation of REE carbonates, obtaining middlings with proper material and granulometric composition, thermal treatment of precipitated carbonates followed with the operations of drying and roasting; classification of roasted oxides, obtaining end products - polishing powders. The production of fluorine-containing powders includes the stage of their fluorination after the stage of carbonate precipitation. The stabilizing doping can be introduced both into the middlings during one of the technological process of powders manufacturing and into the end product. Rare earth polishing powders are manufactured in Russia by the Share Holding Company 'Chepetz Mechanical Plant' (ChMP Co.), the city of Glasov. The plant produces a number of polishing materials, such as; polishing powder Optinol, containing at least 50% by mass of cerium dioxide, used in the mass production of optical and other articles; polishing powder Optinol-10 with doping to improve the sedimentary and aggregate stability of the solid phase

  16. Active condensation of the atmospheric moisture as a self-irrigation mechanism for the ground-covering plants

    Directory of Open Access Journals (Sweden)

    Karpun Yuriy Nikolaevich

    2015-12-01

    Full Text Available Studies conducted at the Subtropical Botanical Garden of Kuban (Utch-Dere, Sochi pretty much allow to explain the abnormally high drought resistance of Liriope graminifolia Lour. and Ophiopogon japonicus Ker.-Gawl., plants that naturally grow mostly in sufficient humidity. Quite low temperatures of the leaves’ surface allow to effectively condense the atmospheric moisture and to direct it along the leaf blade to the ground. The accumulation of condensation water leads to self-irrigation, a mechanism that ensures survival of plants in case of insufficient natural precipitation in the form of rain or fog. Combined with xeromorphic leaves with a thick cuticle and thick branch roots with fusiform bulb-shaped swellings, allowing to store water, makes the named plants extremely resistant to stress factors such as prolonged summer droughts accompanied by high daytime temperatures.

  17. Outlet from the condenser of nuclear power plant Krsko into Sava river

    International Nuclear Information System (INIS)

    Rek, Z.

    1990-01-01

    Paper deals with hot water outflow from condenser of the Nuclear power plant Krsko into river Sava. We are interested in temperature and velocity field along the river. Boundary-domain integral method is used to solve a system of conservative equations. As a result, the time development of the velocity and temperature field at nodes of discrete model is obtained. (author)

  18. Condensate cleaning systems

    International Nuclear Information System (INIS)

    Yamamoto, Michiyoshi; Oosumi, Katsumi; Takashima, Yoshie; Mitani, Shinji.

    1982-01-01

    Purpose: To decrease the frequency for the backwash and regeneration operations due to the increase in the differential pressure resulted from claddings captured in a mixed floor type desalter, and decrease the amount of radioactive liquid wastes of claddings from the condensate systems by removing claddings with electromagnetic filters. Constitution: In an existent plant, a valves is disposed between a condensate pump and a mixed floor type desalter. A pipeway is branched from a condensate pipe between the condensate pipe and the valve, through which condensates are transferred by a pump to an electromagnetic filter such as of a high gradient type electromagntic filter to remove claddings, then returned to a condensate pipe between the valve and the mixed floor type desalter and, thereafter, are removed with ionic components in the mixed floor type desalter and fed to the reactor. (Yoshino, Y.)

  19. Evaluation of ion exchange resin performance in Kuosheng nuclear power plant

    International Nuclear Information System (INIS)

    Wen, T.J.; Chen Huang, T.; Liu, W.C.; Liu, T.C.; Shen, S.C.

    2004-01-01

    Different types and brands of bead and powdered ion exchange resin have been widely used in condensate and reactor water clean-up system in Boiling Water Reactors (BWRs). The importance of primary coolant quality control has been well recognized. Recently, some measures both in promoting the conductivity of reactor water and minimizing iron crud of feed-water have been recommended by the Institute of Nuclear Energy Research. The variation of water quality between the condensate and reactor water is closely related with the performance of condensate polisher and precoat condition. In order to ensure optimization of water chemistry quality in reactor system, historical water chemistry data have been reviewed and evaluated. The most probable causes of exceeding the chemistry limits and guidelines should be identified and some reasonable corrective actions have been documented as a reference for promoting the water quality and run length extending in the plant normal operation. (author)

  20. Recovery of rare earths from used polishes by chemical vapor transport process

    International Nuclear Information System (INIS)

    Ozaki, T.; Machida, K.; Adachi, G.

    1998-01-01

    Full text: Rare earth oxide polishes are widely used in the glass industry because of its mechanical and chemical polishing action. The Japanese glass industry use 2000 tons per year of the polishes, and a large portion of them are thrown away after their polishing lifetime. A dry recovery processes for rare earths from the used polishes have been investigated by using a chemical vapor transport method via the formation of vapor complexes RAl n Cl 3+3n (R = rare earths). A flow type reactor with various temperature gradients was employed for the process. The used polishes were mixed with active carbon, and chlorinated with N 2 + Cl 2 mixture at 1273 K. Aluminium oxide were also chlorinated at lower temperature and the resulting AlCl 3 were introduced to the reactor. The rare earth chlorides and AlCl 3 were converted to the vapor complexes. These were driven along the temperature gradient, decomposed according to the reverse reaction, and regenerated RCl 3 . About 90 % of the used polish were chlorinated after 2 hours. Rare earth chlorides, AlCl 3 , and FeCl 3 were fully transported after 82 hours. The rare earth chlorides were mainly condensed over the temperature range 1263-903 K. On the other hand, AlCl 3 and FeCl 3 were deposited at the temperature range below 413 K. CaCl 2 and SrCl 2 were hardly transported and remained in the residue. When the temperature gradient with the smaller slope was used, mutual separation efficiencies among the rare earths was improved. The highest CeCl 3 purity of 80% was obtained in the process

  1. Device for the analysis of feedwater and condensation samples from power plants

    International Nuclear Information System (INIS)

    Mostofin, A.A.; Sorokina, N.S.

    1978-01-01

    An improved version of a device for automatic measurement of the salt and NH 3 contents of feedwater and condensate samples from nuclear power plants is described. Only one sample is required for determining both values. The invention proposes on the one hand to change the dimensions of a throttle opening and on the other to install a second measuring instrument (conductivity measuring instrument). (UWI) [de

  2. Polish-Bulgarian-Russian, Bulgarian-Polish-Russian or Russian-Bulgarian-Polish dictionary?

    Directory of Open Access Journals (Sweden)

    Violetta Koseska-Toszewa

    2015-11-01

    Full Text Available Polish-Bulgarian-Russian, Bulgarian-Polish-Russian or Russian-Bulgarian-Polish dictionary? The trilingual dictionary (M. Duszkin, V. Koseska, J. Satoła and A. Tzoneva is being elaborated based on a working Polish-Bulgarian-Russian electronic parallel corpus authored by Maksim Duszkin, Violetta Koseska-Toszewa and Joanna Satoła-Staśkowiak, and works by A. Tzoneva. It is the first corpus comparing languages belonging to three different Slavic language groups: western, southern and eastern. Works on the dictionary are based on Gramatyka konfrontatywna bułgarsko-polska (Bulgarian-Polish confrontative grammar and the proposed there semantic-oriented interlanguage. Two types of classifiers have been introduced into the dictionary: classic and semantic. The trilingual dictionary will present a consistent and homogeneous set of facts of grammar and semantics. The Authors point out that in a traditional dictionary it is not clear for example whether aspect should be understood as imperfective / perfective form of a verb or as its meaning. Therefore in the dictionary forms and meaning are separated in a regular way. Imperfective verb form has two meanings: state and configuration of states and events culminating in state. Also perfective verb form has two meanings: event and configuration of states and events culminating in event. These meanings are described by the semantic classifiers, respectively, state and event, state1 and event1. The way of describing language units, mentioned in the article, gives a possibility to present language material (Polish, Bulgarian, Russian in any required order, hence the article’s title.

  3. Apparatus and method for depressurizing, degassing, and affording decay of the radioactivity of weakly radioactive condensates in nuclear power plants

    International Nuclear Information System (INIS)

    Gross, R.; Plotz, J.

    1976-01-01

    Described is an apparatus for depressurizing, degassing and affording decay of weakly radioactive condensates in nuclear power plants having a turbine and a main condenser turbine wherein exhaust steam of the turbine is condensed and forms a main condensate, and includes a collecting tank for the condensate situated below the condenser. A plurality of horizontal degassing channels, each having a lateral overflow, are disposed in the upper part of the condensate collecting tank and are filled with the main condensate up to the level of the overflow. At least one feedwater preheater which is heated by bleeder steam from the turbine provides a secondary condensate. Below the overflow height of the degassing channels extend horizontal feed pipes for the secondary condensate. The feed pipes are connected to the output of pressure relieving expanding devices and are provided on their underside with discharge openings for the bubbling of the secondary condensate into the main condensate to thereby degass the main condensate. The condensate collecting tank has mutually offset partitions therein providing an adequately long path for the decay of the main and secondary condensates. The condensate which is discharged from the condensate collecting tank is returned into the cycle as feedwater. Also disclosed is a method of operating the foregoing apparatus

  4. Acetone enhances the direct analysis of total condensed tannins in plant tissues by the butanol-HCl-iron assay

    Science.gov (United States)

    The butanol-HCl spectrophotometric assay is widely used to quantify extractable and insoluble forms of condensed tannin (CT, syn. proanthocyanidin) in foods, feeds, and foliage of herbaceous and woody plants. However, this method underestimates total CT content when applied directly to plant materia...

  5. Control systems for the dissolved oxygen concentration in condensate- and feed-water systems in nuclear power plants

    International Nuclear Information System (INIS)

    Mikajiri, Motohiko; Hosaka, Seiichi.

    1981-01-01

    Purpose: To surely prevent the generation of corrosion products and contaminations in the systems thereby decreasing the exposure dose to operators in BWR type nuclear power plants. Constitution: Dissolved oxygen concentration in condensates is measured by a dissolved oxygen concentration meter disposed to the pipeway down stream of the condensator and the measured value is sent to an injection amount control mechanism for heater drain water. The control mechanism controls the injection amount from the injection mechanism that injection heater drain water from a feed-water heater to the liquid phase in the hot wall of the condensator. Thus, heater drawin water at high dissolved oxygen is injected to the condensates in the condensator which is de-airated and reduced with dissolved oxygen concentration, to maintain the dissolved oxygen concentration at a predetermined level, whereby stable oxide films are formed to the inner surface of the pipeways to prevent the generation of corrosion products such as rusts. (Furukawa, Y.)

  6. A theoretical and experimental investigation into the thermodynamic performance of a 50 MW power plant with a novel modular air-cooled condenser

    International Nuclear Information System (INIS)

    O'Donovan, Alan; Grimes, Ronan

    2014-01-01

    Economic and environmental restrictions have resulted in an increase in the installation of air-cooled condensers (ACCs) in thermoelectric power plants located in arid regions. The traditional A-frame design is installed most frequently, despite an array of empirical evidence that shows it to suffer from significant inefficiencies. As a result, there is scope for improvement in condenser design and this paper presents one such approach – a novel modular air-cooled condenser (MACC). It is suggested that the unique ability of the MACC to continually vary fan speed could result in efficiency gains over a plant operating with existing state-of-the-art fixed speed ACCs. To determine the impact of installing the MACC on plant output, the steam-side characteristics were established through a series of experimental measurements taken on a full-scale prototype. The experimental arrangement and measurement technique ensured that conditions representative of an operational ACC were maintained throughout. The steam-side characteristics are quantified in terms of temperature, pressure and thermal resistance. Predicted values of these quantities are also presented, calculated from established theory. Both the measurements and predictions were used in a thermodynamic analysis to determine the performance of a 50 MW power plant. Results show that, for a given steam flow rate, increasing fan speed leads to a reduction in condenser pressure which ultimately, results in increased plant output. This occurs up until a certain point, at which further increases in output are offset by larger fan power consumption rates. Thus, an optimum operating point is shown to exist. The results from the thermodynamic analysis demonstrate discrepancies between the plant output evaluated from the measurements and that predicted from theory. In some cases, a difference as large as 1.5% was observed, equating to a 0.8 MW over-prediction by the theory. - Highlights: • A novel modular air

  7. Sulphate issues and learning for secondary loop system at Dayabay Nuclear Power Plant

    International Nuclear Information System (INIS)

    Wang Changchun; Fang Jun; Yao Xuehong; He Yanhong; Chen Bin

    2014-01-01

    Dayabay NPP started up from 1994. There is no condensate polishing system (CPP) with initial design. Unfortunately there happened few times serious issues with sea water leakage into condensate. It was reconstructed and be added CPP from 1997. But we found sulphate concentration in SG will increased after ATE was put into operating, when CPP was out of service, then sulphate concentration decreased. Through the study and research for a few years, we found the root cause and we took these following improvements at site step by step, steam generation blow down water quality was significantly improved: Optimize feed water distribution condition in resin bed. Since the shortcomings of resin bed design, resin is moving up and down during operating. To prevent resin re-separation and broken issue, we improved the structure of feed distribution and better the resin condition in resin bed; Optimize regeneration process. Optimize mixed bed resin transferring, separation, regeneration process, re-separation and re-mixing process during regeneration; Optimize operating process. Regular clean resin beads under the water chamber and resin trap to prevent resin leak into SG system; Other actions. Check nozzles one by one in resin bed and change these nozzles with shortcomings to prevent resin leakage into resin chamber. Upgrade cation resin type from 12% DVB to 16% DVB. According to Dayabay nuclear power plant steam generator sulphate issue experience, now in China we have improved a lot for the secondary loop condensate polishing system design, equipment manufacturing, operation process, etc. We have achieved good results in our new projects such as LingAo Phase II nuclear power plant. (author)

  8. Keeping condensers clean

    Energy Technology Data Exchange (ETDEWEB)

    Wicker, K.

    2006-04-15

    The humble condenser is among the biggest contributors to a steam power plant's efficiency. But although a clean condenser can provide great economic benefit, a dirty one can raise plant heat rate, resulting in large losses of generation revenue and/or unnecessarily high fuel bills. Conventional methods for cleaning fouled tubes range form chemicals to scrapers to brushes and hydro-blasters. This article compares the available options and describes how one power station, Omaha Public Power District's 600 MW North Omaha coal-fired power station, cleaned up its act. The makeup and cooling water of all its five units comes from the Missouri River. 6 figs.

  9. Modelling of condensation phenomena

    International Nuclear Information System (INIS)

    Jeong, Jae Jun; Chang, Won Pyo

    1996-07-01

    Condensation occurs when vapor is cooled sufficiently below the saturation temperature to induce the nucleation of droplets. Such nucleation may occur homogeneously within the vapor or heterogeneously on entrained particular matter. Heterogeneous nucleation may occur on the walls of the system, where the temperature is below the saturation temperature. There are two forms of heterogeneous condensation, drop-wise and film-wise. Another form of condensation occurs when vapor directly contacts to subcooled liquid. In nuclear power plant systems, all forms of condensation may occur during normal operation or accident conditions. In this work the modelling of condensation is surveyed, including the Nusselts' laminar film condensation theory in 1916, Rohsenow's turbulent film condensation model in 1950s, and Chen's models in 1987. Major attention is paid on the film condensation models among various research results because of its importance in engineering applications. It is found that theory, experiment, and empirical correlations for film condensation are well established, but research for drop-wise and direct-contact condensation are not sufficient yet. Condensation models in the best-estimate system codes such as RELAP5/MOD3 and CATHARE2 are also investigated. 3 tabs., 11 figs., 36 refs. (Author)

  10. Polish media and public opinion on NPP Mochovce commissioning

    International Nuclear Information System (INIS)

    Latek, Stanislaw

    1999-01-01

    The so called 'Mochovce Problem' was one of the major topics in Polish media in the period from May to July 1998. The nuclear power plant commissioning caused an unexpectedly strong reaction, especially in the newspapers, slightly less so in electronic media. Faced with clearly hostile media reaction to Mochovce NPP, the National Atomic Energy Agency representatives, together with atomic and nuclear experts, undertook to change these attitudes. In numerous interviews, letters to the editors and talks with journalists, they attempted to correct the mistakes, explain the true safety situation in the nuclear power plant, by whom it was constructed, who supervised and tested the systems and so on. The completion of Mochovce NPP construction improved significantly the electricity balance in Slovakia, thus decreasing the pressure for continuing the operation of older Bohunice V1 units beyond their design lifetime. For this reason, as well as in view of striving for improvement in environmental factors beyond Polish southern border, especially after Kyoto/97 decisions on greenhouse gases emissions, the public opinion in Poland should support the Mochovce NPP construction. In 1996 Poland has signed with Slovakia a bilateral inter-governmental agreement on the prompt notification on nuclear accidents and on the cooperation in the nuclear safety and radiological protection matters. On the basis of this agreement the experts from Polish National Atomic Energy Agency are in perpetual contact with Slovakian Nuclear Regulatory Body and in each and every moment can obtain full and comprehensive information on the plant parameters iportant for nuclear safety. The experts explanations, together with the NAEA top management visit to the plant itself, brought some results. The media became less aggressive, and Polish public and authorities - contrary to the Austrians - do not protest loudly against the commissioning of this newest European NPP. Now, in December 1998, the tune of

  11. Wild vascular plants gathered for consumption in the Polish countryside: a review.

    Science.gov (United States)

    Łuczaj, Łukasz; Szymański, Wojciech M

    2007-04-15

    This paper is an ethnobotanical review of wild edible plants gathered for consumption from the end of the 18th century to the present day, within the present borders of Poland. 42 ethnographic and botanical sources documenting the culinary use of wild plants were analyzed. The use of 112 species (3.7% of the flora) has been recorded. Only half of them have been used since the 1960s. Three species: Cirsium rivulare, Euphorbia peplus and Scirpus sylvaticus have never before been reported as edible by ethnobotanical literature. The list of wild edible plants which are still commonly gathered includes only two green vegetables (Rumex acetosa leaves for soups and Oxalis acetosella as children's snack), 15 folk species of fruits and seeds (Crataegus spp., Corylus avellana, Fagus sylvatica, Fragaria vesca, Malus domestica, Prunus spinosa, Pyrus spp., Rosa canina, Rubus idaeus, Rubus sect. Rubus, Sambucus nigra, Vaccinium myrtillus, V. oxycoccos, V. uliginosum, V. vitis-idaea) and four taxa used for seasoning or as preservatives (Armoracia rusticana root and leaves, Carum carvi seeds, Juniperus communis pseudo-fruits and Quercus spp. leaves). The use of other species is either forgotten or very rare. In the past, several species were used for food in times of scarcity, most commonly Chenopodium album, Urtica dioica, U. urens, Elymus repens, Oxalis acetosella and Cirsium spp., but now the use of wild plants is mainly restricted to raw consumption or making juices, jams, wines and other preserves. The history of the gradual disappearance of the original barszcz, Heracleum sphondylium soup, from Polish cuisine has been researched in detail and two, previously unpublished, instances of its use in the 20th century have been found in the Carpathians. An increase in the culinary use of some wild plants due to media publications can be observed. Poland can be characterized as a country where the traditions of culinary use of wild plants became impoverished very early, compared to

  12. Condenser performance monitoring and cleaning

    International Nuclear Information System (INIS)

    Walden, J.V.

    1998-01-01

    The main condenser at Ginna Station was retubed from admiralty brass to 316 stainless steel. A condenser performance monitoring spreadsheet was developed using EPRI guidelines after fouling was discovered. PEPSE computer models were used to determine the power loss and confirm the spreadsheet results. Cleaning of the condenser was performed using plastic scrubbers. Condenser performance improved dramatically following the cleaning. PEPSE, condenser spreadsheet performance, and actual observed plant data correlated well together. The fouling mechanism was determined to be a common lake bacteria and fungus growth which was combined with silt. Chlorination of the circulating water system at the allowable limits is keeping the biofouling under control

  13. Optimisation of condenser design in waste immobilisation plants (WIP`s)

    Energy Technology Data Exchange (ETDEWEB)

    Rajani, G; Ozarde, P D; Gandhi, P M [Waste Management Projects Division, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    The situation under study is vertical heat exchanger with steam as the condensing vapour and NO{sub x} gases as the non condensible gas. The presence of even a small quantity of non-condensible gas in the condensible vapour has a profound influence on the resistance to heat transfer in the region of liquid-vapour heat transfer. Heat transfer coefficients go on reducing progressively, making condensers prohibitively bulky and hence optimisation of condensers is necessary for carrying out design calculations. The condenser has been divided into segments and for each segment, momentum and energy equations have been established and solved. Finally the average value for overall mass transfer coefficients has been calculated. Parametric studies giving the influence of sub cooling gases, water temperature, exit temperature etc. have been studied. (author). 5 refs., 5 figs., 2 tabs.

  14. Development of passive condensers for accident localization systems at nuclear power plants in the former USSR

    International Nuclear Information System (INIS)

    Kuznecov, M.V.

    1992-01-01

    The development is summarized of passive condensers for accident localization systems at nuclear power plants (with RBMK and WWER reactors) in the former USSR. Basic properties and criteria defining their availability are described, as are experimental tests and technical solution optimization results. (author) 2 fig

  15. Development of balanced downflow type surface condensers, (2)

    International Nuclear Information System (INIS)

    Tomida, Akira; Oshima, Yoshikuni; Okochi, Isao; Izumi, Kenkichi.

    1976-01-01

    As the size of the condensers for power generation plants grew large, the new balanced downflow type condenser was developed and completed on the basis of the experiment on steam flow according to the two-dimensional flow model, the analysis of the performance in a tube nest with a computer, and the studies on the effect of outside liquid film and the reheating deaeration of condensate. When the balanced downflow type condensers were adopted for actual plants, the construction, strength and production method were examined, and the reliability of the new condenser was confirmed by the thermal characteristic experiment with the model similar to the actual machine. The condenser comprises a condenser body, supporting plates, cooling tubes, tube plates, water chambers, and reinforcements, and the cooling tubes are arranged so as to exchange heat effectively. The arrangement of tubes is divided into three regions, namely radiation portion, densely arranged portion, and air cooling portion. In the balanced downflow type condensers, the dilution by utilizing condensate is provided against ammonia attack. The apparatuses for the thermal characteristic experiment and the experimental results, and the results of the performance test on the actual balanced downflow type condenser are reported. (Kako, I.)

  16. Functional design criteria for the 242-A evaporator and PUREX [Plutonium-Uranium Extraction] Plant condensate interim retention basin

    International Nuclear Information System (INIS)

    Cejka, C.C.

    1990-01-01

    This document contains the functional design criteria for a 26- million-gallon retention basin and 10 million gallons of temporary storage tanks. The basin and tanks will be used to store 242-A Evaporator process condensate, the Plutonium-Uranium Extraction (PUREX) Plant process distillate discharge stream, and the PUREX Plant ammonia scrubber distillate stream. Completion of the project will allow both the 242-A Evaporator and the PUREX Plant to restart. 4 refs

  17. Condensed tannins in extracts from European medicinal plants and herbal products.

    Science.gov (United States)

    Ropiak, Honorata M; Ramsay, Aina; Mueller-Harvey, Irene

    2016-03-20

    Medicinal plant materials are not usually analysed for condensed tannins (CT). Thirty commercially available European medicinal plants and herbal products were screened for CT and fourteen CT samples were analysed in detail. This is also the first comprehensive CT analysis of pine buds, walnut leaves, heather flowers and great water dock roots. Acetone/water extracts contained between 3.2 and 25.9 g CT/100g of extract, had CT with mean degrees of polymerisation of 2.9 to 13.3, procyanidin/prodelphinidin ratios of 1.6/98.4 to 100/0 and cis/trans flavan-3-ol ratios of 17.7/82.3 to 97.3/2.7. The majority of samples contained procyanidins, four contained A-type linkages (blackthorn flowers, heather flowers, bilberry leaves and cowberry leaves) and one sample also had galloylated procyanidins (great water dock roots). Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Wild vascular plants gathered for consumption in the Polish countryside: a review

    Directory of Open Access Journals (Sweden)

    Szymański Wojciech M

    2007-04-01

    Full Text Available Abstract Background This paper is an ethnobotanical review of wild edible plants gathered for consumption from the end of the 18th century to the present day, within the present borders of Poland. Methods 42 ethnographic and botanical sources documenting the culinary use of wild plants were analyzed. Results The use of 112 species (3.7% of the flora has been recorded. Only half of them have been used since the 1960s. Three species: Cirsium rivulare, Euphorbia peplus and Scirpus sylvaticus have never before been reported as edible by ethnobotanical literature. The list of wild edible plants which are still commonly gathered includes only two green vegetables (Rumex acetosa leaves for soups and Oxalis acetosella as children's snack, 15 folk species of fruits and seeds (Crataegus spp., Corylus avellana, Fagus sylvatica, Fragaria vesca, Malus domestica, Prunus spinosa, Pyrus spp., Rosa canina, Rubus idaeus, Rubus sect. Rubus, Sambucus nigra, Vaccinium myrtillus, V. oxycoccos, V. uliginosum, V. vitis-idaea and four taxa used for seasoning or as preservatives (Armoracia rusticana root and leaves, Carum carvi seeds, Juniperus communis pseudo-fruits and Quercus spp. leaves. The use of other species is either forgotten or very rare. In the past, several species were used for food in times of scarcity, most commonly Chenopodium album, Urtica dioica, U. urens, Elymus repens, Oxalis acetosella and Cirsium spp., but now the use of wild plants is mainly restricted to raw consumption or making juices, jams, wines and other preserves. The history of the gradual disappearance of the original barszcz, Heracleum sphondylium soup, from Polish cuisine has been researched in detail and two, previously unpublished, instances of its use in the 20th century have been found in the Carpathians. An increase in the culinary use of some wild plants due to media publications can be observed. Conclusion Poland can be characterized as a country where the traditions of culinary

  19. Evaluation of non-condensable gas effect during LBLOCA in an OPR1000 Plant

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seung Hun; Seul, Kwang-Won; Bang, Young-Seok; Lee, Jun Soo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-05-15

    Gas accumulation in the nuclear power plant may cause diverse safety issues such as water hammer, pump cavitation and inadvertent valve actuation. The Nuclear Regulatory Commission (NRC) has published twenty Information Notices, two Generic Letters, and one NUREG report related to the issue of the gas accumulation. It has been considered that gas accumulation occurred since the beginning of commercial nuclear power plant operation and may occur in the currently operating plants. Gas accumulation in the Emergency Core Cooling System (ECCS) is the condition that did not consider in Accident Analysis of Final Safety Analysis Report or Technical Specification and may finally result in degradation or loss of the safety functions. In this paper, the effect of gas accumulation in the ECCS has been analyzed by modeling non-condensable gas injection during the operation of Safety Injection Tank (SIT) and Low Pressure Safety Injection (LPSI) under the LBLOCA condition. Gas accumulation in the ECCS has been dealt with one of significant safety issues in the operating nuclear power plants. In order to identify the effect of the non-condensable gas in Hanul unit 3 and 4, the sensitivity studies for gas quantity, location or injection time was conducted for high or low pressure condition. At high pressure condition, the injected gas induced the reduced SIT flow rate and the reduced period of SIT injection. The reflood PCT at 5 ft''3 condition was 1150 K which was 49K higher than that at no gas condition. At low pressure condition, the reduced flow rate and the increased reflood PCT were also identified. However, the PCT deviation due to different gas quantity was not large as much as that at high pressure condition. We concluded that it is necessary to evaluate the effect of the accumulated gas with the consideration of plant- specific conditions such as system pressure, accumulated location, gas quantity and injection time.

  20. Off gas condenser performance modelling

    International Nuclear Information System (INIS)

    Cains, P.W.; Hills, K.M.; Waring, S.; Pratchett, A.G.

    1989-12-01

    A suite of three programmes has been developed to model the ruthenium decontamination performance of a vitrification plant off-gas condenser. The stages of the model are: condensation of water vapour, NO x absorption in the condensate, RuO 4 absorption in the condensate. Juxtaposition of these stages gives a package that may be run on an IBM-compatible desktop PC. Experimental work indicates that the criterion [HNO 2 ] > 10 [RuO 4 ] used to determine RuO 4 destruction in solution is probably realistic under condenser conditions. Vapour pressures of RuO 4 over aqueous solutions at 70 o -90 o C are slightly lower than the values given by extrapolating the ln K p vs. T -1 relation derived from lower temperature data. (author)

  1. Control of feedwater composition of BWR power plant

    International Nuclear Information System (INIS)

    Sturla, P.; D'Anna, A.; Borgese, D.

    1983-01-01

    Corrosion behaviour of fuel element cladding, cycle structural materials and dose rate increase are relevant to physico-chemical characteristics of process coolants and to adopted operational conditions. A careful control of cycle chemistry, during loading and shutdown periods, is necessary to verify material choices, the polishing system and chemistry specifications. For this purpose ENEL carried out some preliminary experimental tests employing continuous control system and samples for specific analytical determinations. The cycle points checked during about two months were: main condensate; condensate after polishing system; outlet of low pressure heathers; final feedwater; inlet and outlet of clean-up system; drains to condenser. The physico-chemical analysis were related to corrosion product levels (Cu, Fe, Ni, Co) and water chemistry (pH, conductivity, dissolved oxygen etc.). The preliminary results allow to express some considerations about sampling procedures, detection limits and reliability of analytical employed methods. The acquisition data time and some morphological oxide pictures are also showed. (author)

  2. Infestation of Polish Agricultural Soils by Plasmodiophora Brassicae Along The Polish-Ukrainian Border

    Directory of Open Access Journals (Sweden)

    Jędryczka Małgorzata

    2014-07-01

    Full Text Available There has been a rapid, worldwide increase in oilseed rape production that has resulted in enormous intensification of oilseed rape cultivation, leading to tight rotations. This in turn, has caused an accumulation of pests as well as foliar and soil-borne diseases. Recently, clubroot has become one of the biggest concerns of oilseed rape growers. Clubroot is caused by the soil-borne protist Plasmodiophora brassicae Woronin. The pathogen may be present in groundwater, lakes, and irrigation water used in sprinkling systems. It can be easily transmitted from one field to another not only by water, but also by soil particles and dust transmitted by wind and on machinery. The aim of our overall study was to check for P. brassicae infestation of Polish agricultural soils. This paper presents the 2012 results of a study performed along the Polish-Ukrainian border in two provinces: Lublin (Lubelskie Voivodeship and the Carpathian Foothills (Podkarpackie Voivodeship, in south-east Poland. Monitoring was done in 11 counties, including nine rural and two municipal ones. In total, 40 samples were collected, out of which 36 were collected from fields located in rural areas and four from municipal areas, with two per municipal region. Each sample was collected at 8-10 sites per field, using a soil auger. The biotest to detect the presence of P. brassicae was done under greenhouse conditions using seedlings of the susceptible Brassicas: B. rapa ssp. pekinensis and the Polish variety of oilseed rape B. napus cv. Monolit. Susceptible plants grown in heavily infested soils produced galls on their roots. A county was regarded as free from the pathogen, if none of the bait plants became infected. The pathogen was found in three out of 40 fields monitored (7.5% in the Carpathian Foothill region. The fields were located in two rural counties. The pathogen was not found in Lublin province, and was also not detected in any of the municipal counties. The detection with

  3. Condensed tannins act against cattle nematodes

    DEFF Research Database (Denmark)

    Novobilský, Adam; Mueller-Harvey, Irene; Thamsborg, Stig Milan

    2011-01-01

    The use of natural plant anthelmintics was suggested as a possible alternative control of gastrointestinal nematodes (GIN) in ruminants. Direct anthelmintic effects of tannin-containing plants have already been shown in sheep and goat GIN. These anthelmintic properties are mainly associated...... with condensed tannins. In the present study, we evaluated possible in vitro effects of three tannin-containing plants against bovine GIN. Effects of Onobrychis viciifolia, Lotus pedunculatus and Lotus corniculatus condensed tannin (CT) extracts on Cooperia oncophora and Ostertagia ostertagi were determined...... (third stage larvae) was also affected by CT extracts from all three plants. In both in vitro assays, extracts with added polyvinylpolypyrrolidone, an inhibitor of tannins, generated almost the same values as the negative control; this confirms the role of CT in the anthelmintic effect of these plant...

  4. Assessment of ISLOCA risk: Methodology and application to a Westinghouse four-loop ice condenser plant

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, D.L.; Auflick, J.L.; Haney, L.N. [EG and G Idaho, Inc., Idaho Falls, ID (United States)

    1992-04-01

    Inter-system loss-of-coolant accidents (ISLOCAs) have been identified as important contributors to offsite risk for some nuclear power plants. A methodology has been developed for identifying and evaluating plant-specific hardware designs, human factors issues, and accident consequence factors relevant to the estimation of ISLOCA core damage frequency and risk. This report presents a detailed description of the application of this analysis methodology to a Westinghouse four-loop ice condenser plant. This document also includes appendices A through I which provide: System descriptions; ISLOCA event trees; human reliability analysis; thermal hydraulic analysis; core uncovery timing calculations; calculation of system rupture probability; ISLOCA consequences analysis; uncertainty analysis; and component failure analysis.

  5. Assessment of ISLOCA risk: Methodology and application to a Westinghouse four-loop ice condenser plant

    International Nuclear Information System (INIS)

    Kelly, D.L.; Auflick, J.L.; Haney, L.N.

    1992-04-01

    Inter-system loss-of-coolant accidents (ISLOCAs) have been identified as important contributors to offsite risk for some nuclear power plants. A methodology has been developed for identifying and evaluating plant-specific hardware designs, human factors issues, and accident consequence factors relevant to the estimation of ISLOCA core damage frequency and risk. This report presents a detailed description of the application of this analysis methodology to a Westinghouse four-loop ice condenser plant. This document also includes appendices A through I which provide: System descriptions; ISLOCA event trees; human reliability analysis; thermal hydraulic analysis; core uncovery timing calculations; calculation of system rupture probability; ISLOCA consequences analysis; uncertainty analysis; and component failure analysis

  6. Organics in the power plant cycle. An EPRI perspective

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, James A. [EPRI, Charlotte, NC (United States)

    2008-11-15

    Irrespective of past practices and prejudices, the use of organic treatment chemicals to address new and ongoing concerns in the operation of power plant cycles is increasing. Electric Power Research Institute (EPRI) guidelines currently do not advocate the use of organic additives, citing that these additives should not be needed and that breakdown products pose problems with analytical measurement of cation conductivity and operation of condensate polishers. Some of the concerns about organic treatment are hidden in the association of ''organics'' with naturally occurring organic compounds from contamination sources such as cooling water, lubrication systems, or make-up water treatment and cleaning agents. However, conditions in the 2-phase fluid regions of low pressure heat recovery steam generators (HRSGs), feedwater heaters, the turbine phase transition zone (PTZ), and air-cooled condensers remain problematic and warrant investigation of conditioning with some complex amine type organic treatments. Nuclear plants have employed advanced organic amines such as ethanolamine to address concerns of low pH in condensing steam. Increasing understanding of the formation, morphology and dynamics of boiler deposits may demonstrate the capability to modify the deposit nature and restrict the accumulation of contaminants; what role potential organic treatments may have in this is unclear at this time. The aim of EPRI in the assessment of organics in the fossil power plant cycle is to accomplish a greater understanding of the role, risks and benefits of organic treatment and to more fully engage the technical community in adoption of best practices for the optimum use of these treatments. (orig.)

  7. Control systems for condensing flue-gas coolers related to natural-gas-fired heating plants

    International Nuclear Information System (INIS)

    Krighaar, M.; Paulsen, O.

    1992-01-01

    A theoretical study is made of the enthalpy-efficiency for a water-cooled heat exchanger added to a natural gas-fired boiler. Under varying conditions of both water flow and temperature and flue-gas flow and temperature, both in condensing and non-condensing mode, the efficiency seems to be constant. The result is very useful for comparison between two different working conditions. The efficiency is used to calculate the savings achieved for a district heating plant by using a heat exchanger. The energy economic calculations are also helpful for estimating the most appropriate size of heat exchanger. The annual savings are calculated by means of data regarding heat production, flue gas temperature and water return temperature. The savings achieved by using different connection principles such as bypass, reheating and controlled water temperature are also calculated. (author)

  8. Cancer morbidity among polishers.

    Science.gov (United States)

    Järvholm, B; Thiringer, G; Axelson, O

    1982-01-01

    The mortality pattern among 86 men was determined to investigate the possible hazards of polishing steel. The men had polished steel with polishing paste for at least five years. The polishing pastes had contained tallow, beeswax, carnauba wax, alundum, carborundum, ferric oxide, and chalk. A total of 18 men had died compared with 13.3 expected. Four had died of stomach cancer compared with 0.44 expected (p less than 0.005). The mortality for other causes of death was not increased. The study does not permit any definite conclusion but indicates a possible cancer hazard among polishers. PMID:7066237

  9. Polishing large NaCl windows on a continuous polisher

    International Nuclear Information System (INIS)

    Williamson, R.

    1979-01-01

    The Helios and Antares CO 2 fusion laser systems incorporate numerous large sodium chloride windows. These must be refinished periodically, making necessary a consistent and predictable polishing capability. A continuous polisher (or annular lap) which might at Kirtland's Developmental Optical Facility. Large NaCl windows had not been polished on this type of machine. The machine has proven itself capable of producing lambda/16 figures at 633 nm (HeNe) with extremely smooth surfaces on glass. Since then, we have been working exclusively on NaCl optics. Due to different polishing parameters between NaCl and glass, and the slight solubility of the pitch in the slurry, this phase presents new problems. The work on glass will be reviewed. Results on NaCl to date will be reported. The potential of this type of machine relative to prisms, thin and irregularly shaped optics will be discussed

  10. Improved methods of online monitoring and prediction in condensate and feed water system of nuclear power plant

    International Nuclear Information System (INIS)

    Wang, Hang; Peng, Min-jun; Wu, Peng; Cheng, Shou-yu

    2016-01-01

    Highlights: • Different methods for online monitoring and diagnosis are summarized. • Numerical simulation modeling of condensate and feed water system in nuclear power plant are done by FORTRAN programming. • Integrated online monitoring and prediction methods have been developed and tested. • Online monitoring module, fault diagnosis module and trends prediction module can be verified with each other. - Abstract: Faults or accidents may occur in a nuclear power plant (NPP), but it is hard for operators to recognize the situation and take effective measures quickly. So, online monitoring, diagnosis and prediction (OMDP) is used to provide enough information to operators and improve the safety of NPPs. In this paper, distributed conservation equation (DCE) and artificial immunity system (AIS) are proposed for online monitoring and diagnosis. On this basis, quantitative simulation models and interactive database are combined to predict the trends and severity of faults. The effectiveness of OMDP in improving the monitoring and prediction of condensate and feed water system (CFWS) was verified through simulation tests.

  11. Coupling of standard condensing nuclear power stations to horizontal aluminium tubes multieffect distillation plants

    International Nuclear Information System (INIS)

    Adar, J.

    1977-01-01

    No large nuclear back-pressure turbines are available to-day. Standard condensing nuclear turbines could operate continuously with a back-pressure of up to 7'' Hg, exhausting huge amounts of steam at 56degC-64degC with a loss of electricity production of only 6%-10%. The horizontal aluminium tube multieffect distillation process developed by 'Israel Desalination Engineering Ltd' is very suitable for the use of such low-grade heat. A special flash-chamber loop constitutes a positive barrier against any possible contamination being carried over by the steam exhausted from the turbine to the desalination plant. The operation is designed to be flexible so that the power plant can be operated either in conjunction with the desalination plant or as a single purpose plant. Flow sheets, heat and mass balances have been prepared for eight different combinations of plants. Only standard equipment is being used in the power plant. The desalination plant consists of 6 to 12 parallel double lines, each of them similar to a large prototype now being designed. Water production varies between 50 and 123 MGD and water cost between 90 and 137 c/1000 gallons. Costs are based on actual bids

  12. Geysers advanced direct contact condenser research

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, J.; Bahning, T.; Bharathan, D.

    1997-12-31

    The first geothermal application of the Advanced Direct Contact Condenser (ADCC) technology developed by the National Renewable Energy Laboratory (NREL) is now operational and is being tested at The Geysers Power Plant Unit 11. This major research effort is being supported through the combined efforts of NREL, The Department of Energy (DOE), and Pacific Gas and Electric (PG&E). NREL and PG&E have entered into a Cooperative Research And Development Agreement (CRADA) for a project to improve the direct-contact condenser performance at The Geysers Power Plant. This project is the first geothermal adaptation of an advanced condenser design developed for the Ocean Thermal Energy Conversion (OTEC) systems. PG&E expects this technology to improve power plant performance and to help extend the life of the steam field by using steam more efficiently. In accordance with the CRADA, no money is transferred between the contracting parties. In this case the Department of Energy is funding NREL for their efforts in this project and PG&E is contributing funds in kind. Successful application of this technology at The Geysers will provide a basis for NREL to continue to develop this technology for other geothermal and fossil power plant systems.

  13. Evolution of the feedback from experience on degradations of French nuclear power plants condensers and foreseen solutions

    Energy Technology Data Exchange (ETDEWEB)

    Mayos, M.; Chanel, F.; Copin, E.; Carlier, L. [EDF/DIN/CEIDRE, Saint-Denis (France); Coquio, N.; Garbay, E. [EDF/DIN/CEIDRE, Avoine (France); Bastian, C. [EDF/DPN/UNIE, Saint-Denis (France)

    2011-07-01

    The materials constituting the condenser tubes of French nuclear power plants display a great diversity and are subject to different degradations, known from the operational feedback from experience. Copper alloys (mainly brass), which were bound to disappear in renovated condensers, are still significantly present, due to their unique bacteriostatic ability. Brass tubes lifetime is still governed in general by steady abrasion, as evaluated by eddy current nondestructive testing. However, an atypical NDE (non-destructive evaluation) behavior has led to spot a new damage: localized under-deposit pitting corrosion on the raw water side, caused by the particular quality of water chemistry and heavy scaling of the tube surface. This damage is likely to overcome steady abrasion for tube life prediction. Prevention includes a tighter look at NDE indications and improved descaling solutions (chemical or mechanical). Other specific damages have been reported from operation feedback: the main one was accidental stress corrosion cracking, which has occurred on some recently renovated brass condenser tube bundles. Thanks to a metallurgical and mechanical study, its cause was found in the manufacturing process. This experience has resulted in tightened specifications for brass tubes manufacturing. Stainless steel and titanium still appear more damage-resistant and represent a safe solution when no microorganism issue is present. The degradation feedback, confirmed by NDE inspections, is very low in French power plants. However, titanium hydriding still represents an issue when cathodic protection is present. Furthermore, some other damages have been reported on titanium, like isolated steam erosion. Vibration fatigue damage has been observed on stainless steel tubes, but it is more in relationship with the condenser design than with the material itself. (authors)

  14. Fly ashes from Polish power plants and combined heat and power plants and conditions of their application for carbon dioxide utilization

    Energy Technology Data Exchange (ETDEWEB)

    Uliasz-Bochenczyk, A.; Mokrzycki, E. [Polish Academy of Science, Krakow (Poland). Mineral & Energy Economic Research Institute

    2006-09-15

    Poland has large resources of hard coal and brown coal. Therefore power industry is mostly based on these two original energy carriers. The power plants producing heat and electrical energy create combustion byproducts. These products include: fly ashes, slags, carbon dioxide and other gaseous compounds. In year 2003 fly ashes emission from hard coal combustion in Poland reached 37 000 tons and over 15 000 tons from brown coal combustion. Fly ashes are widely used in the economy. They are used in building materials industry, in road building and geotechnics. CO{sub 2} emission in Poland in 2003 originating from hard coal combustion was almost 91 million tons and from brown coal combustion-almost 58 million tons. High emissions of CO{sub 2} originating from power engineering processes of coal combustion are deleterious to the natural environment, contributing to the greenhouse effect. Presently there are carried out studies aimed at limiting CO{sub 2} emission coming from industrial processes. Fly ash properties are determined by qualitative characteristics of combusted coal, its chemical composition and combustion technology. Chemical composition of Polish fly ashes is very diversified. Fly ashes with high calcium oxide content can be used for carbon dioxide fixation. Fly ash carbonation is a complicated process however safe for natural environment. Polish fly ashes coming from power engineering, conditions of their use for the carbon dioxide utilization as well as their quantitative and qualitative characteristics are the subjects of this paper.

  15. Convergent Polishing: A Simple, Rapid, Full Aperture Polishing Process of High Quality Optical Flats & Spheres

    Science.gov (United States)

    Suratwala, Tayyab; Steele, Rusty; Feit, Michael; Dylla-Spears, Rebecca; Desjardin, Richard; Mason, Dan; Wong, Lana; Geraghty, Paul; Miller, Phil; Shen, Nan

    2014-01-01

    Convergent Polishing is a novel polishing system and method for finishing flat and spherical glass optics in which a workpiece, independent of its initial shape (i.e., surface figure), will converge to final surface figure with excellent surface quality under a fixed, unchanging set of polishing parameters in a single polishing iteration. In contrast, conventional full aperture polishing methods require multiple, often long, iterative cycles involving polishing, metrology and process changes to achieve the desired surface figure. The Convergent Polishing process is based on the concept of workpiece-lap height mismatch resulting in pressure differential that decreases with removal and results in the workpiece converging to the shape of the lap. The successful implementation of the Convergent Polishing process is a result of the combination of a number of technologies to remove all sources of non-uniform spatial material removal (except for workpiece-lap mismatch) for surface figure convergence and to reduce the number of rogue particles in the system for low scratch densities and low roughness. The Convergent Polishing process has been demonstrated for the fabrication of both flats and spheres of various shapes, sizes, and aspect ratios on various glass materials. The practical impact is that high quality optical components can be fabricated more rapidly, more repeatedly, with less metrology, and with less labor, resulting in lower unit costs. In this study, the Convergent Polishing protocol is specifically described for fabricating 26.5 cm square fused silica flats from a fine ground surface to a polished ~λ/2 surface figure after polishing 4 hr per surface on a 81 cm diameter polisher. PMID:25489745

  16. Review of steam jet condensation in a water pool

    International Nuclear Information System (INIS)

    Kim, Y. S.; Song, C. H.; Park, C. K.; Kang, H. S.; Jeon, H. G.; Yoon, Y. J.

    2002-01-01

    In the advanced nuclear power plants including APR1400, the SDVS is adopted to increase the plant safety using the concept of feed-and-bleed operation. In the case of the TLOFW, the POSRV located at the top of the pressurizer is expected to open due to the pressurization of the reactor coolant system and discharges steam and/or water mixture into the water pool, where the mixture is condensed. During the condensation of the mixture, thermal-hydraulic loads such as pressure and temperature variations are induced to the pool structure. For the pool structure design, such thermal-hydraulic aspects should be considered. Understanding the phenomena of the submerged steam jet condensation in a water pool is helpful for system designers to design proper pool structure, sparger, and supports etc. This paper reviews and evaluates the steam jet condensation in a water pool on the physical phenomena of the steam condensation including condensation regime map, heat transfer coefficient, steam plume, steam jet condensation load, and steam jet induced flow

  17. Internalisation of external costs in the Polish power generation sector: A partial equilibrium model

    International Nuclear Information System (INIS)

    Kudelko, Mariusz

    2006-01-01

    This paper presents a methodical framework, which is the basis for the economic analysis of the mid-term planning of development of the Polish energy system. The description of the partial equilibrium model and its results are demonstrated for different scenarios applied. The model predicts the generation, investment and pricing of mid-term decisions that refer to the Polish electricity and heat markets. The current structure of the Polish energy sector is characterised by interactions between the supply and demand sides of the energy sector. The supply side regards possibilities to deliver fuels from domestic and import sources and their conversion through transformation processes. Public power plants, public CHP plants, industry CHP plants and municipal heat plants represent the main producers of energy in Poland. Demand is characterised by the major energy consumers, i.e. industry and construction, transport, agriculture, trade and services, individual consumers and export. The relationships between the domestic electricity and heat markets are modelled taking into account external costs estimates. The volume and structure of energy production, electricity and heat prices, emissions, external costs and social welfare of different scenarios are presented. Results of the model demonstrate that the internalisation of external costs through the increase in energy prices implies significant improvement in social welfare

  18. Functional Median Polish

    KAUST Repository

    Sun, Ying

    2012-08-03

    This article proposes functional median polish, an extension of univariate median polish, for one-way and two-way functional analysis of variance (ANOVA). The functional median polish estimates the functional grand effect and functional main factor effects based on functional medians in an additive functional ANOVA model assuming no interaction among factors. A functional rank test is used to assess whether the functional main factor effects are significant. The robustness of the functional median polish is demonstrated by comparing its performance with the traditional functional ANOVA fitted by means under different outlier models in simulation studies. The functional median polish is illustrated on various applications in climate science, including one-way and two-way ANOVA when functional data are either curves or images. Specifically, Canadian temperature data, U. S. precipitation observations and outputs of global and regional climate models are considered, which can facilitate the research on the close link between local climate and the occurrence or severity of some diseases and other threats to human health. © 2012 International Biometric Society.

  19. ICECON: a computer program used to calculate containment back pressure for LOCA analysis (including ice condenser plants)

    International Nuclear Information System (INIS)

    1976-07-01

    The ICECON computer code provides a method for conservatively calculating the long term back pressure transient in the containment resulting from a hypothetical Loss-of-Coolant Accident (LOCA) for PWR plants including ice condenser containment systems. The ICECON computer code was developed from the CONTEMPT/LT-022 code. A brief discussion of the salient features of a typical ice condenser containment is presented. Details of the ice condenser models are explained. The corrections and improvements made to CONTEMPT/LT-022 are included. The organization of the code, including the calculational procedure, is outlined. The user's manual, to be used in conjunction with the CONTEMPT/LT-022 user's manual, a sample problem, a time-step study (solution convergence) and a comparison of ICECON results with the results of the NSSS vendor are presented. In general, containment pressure calculated with the ICECON code agree with those calculated by the NSSS vendor using the same mass and energy release rates to the containment

  20. Abstracts Book of 41. Scientific Assembly of Polish Chemical Society and Association of Engineers and Technicians of Chemical Industry

    International Nuclear Information System (INIS)

    1998-01-01

    Scientific Assembly of Polish Chemical Society and Association of Engineers and Technicians of Chemical Industry is the most important scientific forum of Polish Chemists. The state of the art in many basic, fundamental and applied investigations has been presented and discussed. The following scientific sessions and microsymposia have been proposed: theoretical chemistry; molecular interactions; metal compounds - chemical, physical, electronic and biological aspects; catalysis and surface physico-chemistry; polymers - radiochemistry, modifications, physics and analytical methods; organic and bioorganic chemistry; physico-chemistry of condensed matter; chemical metallurgy; environmental protection; inorganic technology; chemistry and technology of coal; radiation chemistry; analytical chemistry; chemical engineering; young scientists forum; chemical didactics; petrochemistry; energetic materials; membranes and membrane processes; medical chemistry

  1. Functional Median Polish

    KAUST Repository

    Sun, Ying; Genton, Marc G.

    2012-01-01

    polish is demonstrated by comparing its performance with the traditional functional ANOVA fitted by means under different outlier models in simulation studies. The functional median polish is illustrated on various applications in climate science

  2. Suppression/reducing method for total organic carbon in feedwater/condensate

    International Nuclear Information System (INIS)

    Maeda, Katsuharu.

    1993-01-01

    The present invention suppresses/reduces the concentration of the total organic carbon before the startup of a reactor, to decrease (TOC) which is brought into the reactor upon startup of the operation and suppress/moderate degradation of water quality of reactor water. That is, in-service period of a condensate desalting tower is shortened, to avoid concentration increase of TOC in feed water/condensate which is leached out from the condensate desalting tower. The condensate desalting towers are put to in-service for the entire towers after increasing the vacuum degree of the condensator, to suppress leaching of TOC from the condensate desalting tower. Further, upon startup of a nuclear power plant, when the condensate desalting tower is put to in-service, condensate filters of the entire towers are previously back-washed and regenerated to remove TOC efficiently. By these procedures, TOC brought from a water supply system upon startup of the plant is thermally decomposed or radiolyzed in the reactor, thereby enabling to suppress/avoid worsening of water quality of reactor water caused by generated ion impurities. (I.S.)

  3. Experience with the use of SF6 to locate condenser leakage in power plants

    International Nuclear Information System (INIS)

    Tondi, D.M.

    1988-01-01

    Condenser tube water inleakage is a prime source of contamination in power plant steam systems. Conventional techniques of leaking-tube detection require periods of reduced power operation. A new method, using sulfur hexafluoride as a tracer gas, can detect leaking tubes while the plant is operating. Sulfur hexafluoride is a gas that when entrained in the cooling water will follow the water through the leak, be volatilized by the vacuum and heat in the condenser, and be detected in the off-gas. The technique will provide positive identification of a leaking waterbox. Sulfur hexafluoride is innocuous, insoluble, thermally stable, and non-toxic. Its most important characteristic in this application is that it can be detected in very low concentration. This high sensitivity enables waterbox testing to be performed while the unit is on line and at full power. The technique has been used at more than 30 fossil and nuclear stations. Tests show that leaking waterboxes can be isolated, and that leaks of less than one gallon per day are readily detectable. There are several cost benefits associated with this technology. One which can be quantified is the cost for replacement power. The process of reducing power in order to silate a leaking waterbox can cost in excess of 30,000 dollars for even a small unit. In addition to direct cost savings, water chemistry can be improved since sensitivity to leakage is generally greater than station chemistry capabilities. Test results from service work at a range of typical plants will be discussed including: estimations of detected leak rates, injection points and rates, and approximately cost savings

  4. Diagnosis of condensation-induced waterhammer: Case studies

    International Nuclear Information System (INIS)

    Izenson, M.G.; Rothe, P.H.; Wallis, G.B.

    1988-10-01

    This guidebook provides reference material and diagnostic procedures concerning condensation-induced waterhammer in nuclear power plants. Condensation-induced waterhammer is the most damaging form of waterhammer, and its diagnosis is complicated by the complex nature of the underlying phenomena. In Volume 1, the guidebook groups condensation-induced waterhammers into five event classes which have similar phenomena and levels of damage. Diagnostic guidelines focus on locating the event center where condensation and slug acceleration take place. Diagnosis is described in three stages: an initial assessment, detailed evaluation and final confirmation. Graphical scoping analyses are provided to evaluate whether an event from one of the event classes could have occurred at the event center. Examples are provided for each type of waterhammer. Special instructions are provided for walking down damaged piping and evaluating damage due to waterhammer. To illustrate the diagnostic methods and document past experience, six case studies have been compiled in Volume 2. These case studies, based on actual condensation-induced waterhammer events at nuclear plants, present detailed data and work through the event diagnosis using the tools introduced in the first volume. 20 refs., 21 figs., 6 tabs

  5. Experimental study of condensate subcooling with the use of a model of an air-cooled condenser

    Science.gov (United States)

    Sukhanov, V. A.; Bezukhov, A. P.; Bogov, I. A.; Dontsov, N. Y.; Volkovitsky, I. D.; Tolmachev, V. V.

    2016-01-01

    Water-supply deficit is now felt in many regions of the world. This hampers the construction of new steam-turbine and combined steam-and-gas thermal power plants. The use of dry cooling systems and, specifically, steam-turbine air-cooled condensers (ACCs) expands the choice of sites for the construction of such power plants. The significance of condensate subcooling Δ t as a parameter that negatively affects the engineering and economic performance of steam-turbine plants is thereby increased. The operation and design factors that influence the condensate subcooling in ACCs are revealed, and the research objective is, thus, formulated properly. The indicated research was conducted through physical modeling with the use of the Steam-Turbine Air-Cooled Condenser Unit specialized, multipurpose, laboratory bench. The design and the combined schematic and measurement diagram of this test bench are discussed. The experimental results are presented in the form of graphic dependences of the condensate subcooling value on cooling ratio m and relative weight content ɛ' of air in steam at the ACC inlet at different temperatures of cooling air t ca ' . The typical ranges of condensate subcooling variation (4 ≤ Δ t ≤ 6°C, 2 ≤ Δ t ≤ 4°C, and 0 ≤ Δ t ≤ 2°C) are identified based on the results of analysis of the attained Δ t levels in the ACC and numerous Δ t reduction estimates. The corresponding ranges of cooling ratio variation at different temperatures of cooling air at the ACC inlet are specified. The guidelines for choosing the adjusted ranges of cooling ratio variation with account of the results of experimental studies of the dependences of the absolute pressure of the steam-air mixture in the top header of the ACC and the heat flux density on the cooling ratio at different temperatures of cooling air at the ACC inlet are given.

  6. Analytical study of condensation heat transfer on titanium tube with super-hydrophobic surface

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Dae Yun; Park, Hyun Gyu; Lee, Kwon Yeong [Handong Global University, Pohang (Korea, Republic of)

    2016-05-15

    There are many nuclear or fossil power plants which occupy more than 85% among entire power plants in the world. These plants release heat through condenser into nature. The condenser is an important component for cooling the working fluid after the turbine. Its performance is related with material and size of its tubes. To have good performance or to reduce condenser size, it is important to increase condensation heat transfer coefficient on condenser tubes. Ma et al. executed heat transfer experiment in dropwise condensation with non-condensable gas, and studied how the amount of air and pressure difference affect condensation heat transfer coefficient. The more non-condensable gas existed, the condensation heat transfer coefficient was decreased. Shen et al. studied condensation heat transfer at horizontal bundle tubes. Several variables such as coolant velocity, saturated pressure, and surface conditions were studied. As a result, surface modified brass tube and stainless tube showed higher condensation heat transfer coefficient as much as 1.3 and 1.4 times comparing with their bare tubes, in 70 kPa vacuum condition respectively. Rausch et al. studied dropwise condensation on ion-implanted titanium surface. Experimental study is performed to evaluate the performance of surface modified titanium tube in vacuum state. SAM coating is used to make super-hydrophobic surface of titanium tube. Preliminary analysis were performed considering filmwise and dropwise condensations, respectively. Experiment facility is almost prepared and the test result will be shown soon.

  7. Health Information in Polish (polski)

    Science.gov (United States)

    ... Tools You Are Here: Home → Multiple Languages → Polish (polski) URL of this page: https://medlineplus.gov/languages/polish.html Health Information in Polish (polski) To use the sharing features on this page, ...

  8. Scandinavian experience of titanium condensers

    International Nuclear Information System (INIS)

    Multer, I.; Hedstroem, M.

    1985-01-01

    The Albrass condenser tubing in Sweden and Finnish nuclear power plants has caused much concern. After the appearance of the first tube leak, the deterioration has been very rapid. A typical development is represented by the Ringhals unit 2 eddy current (EC) measurements. They are, despite the difference in salinity, almost identical with Forsmark units 1 and 2 and units 1 and 2 of the TVO power company at Olkiluoto, Finland. For instance, in summer 1984, 3000 tubes were plugged in TVO 2 after four years of operation. The cause was pitting and/or erosion-corrosion. The failure rate, although the plugging criteria have been different from the EPRI concept, has exceeded that reported in the US and UK; and it has been necessary, especially with the strict feed water chemistry requirements in the PWR's, to arrange for retubing after a very short time, approximately 3 years after the first leak. The history of the nuclear plant condensers is shown; the average condenser life span has been approximately 6.5 years

  9. Mitigation of corrosion product ingress into SG's

    International Nuclear Information System (INIS)

    Han, S.H.

    1988-01-01

    Design and operation experiences to mitigate corrosion product ingress into SGs in Korea nuclear power plants are briefly reviewed. Maintaining the feedwater pH above 9.6 with morpholine seems to contribute significantly to reduction of iron transport to SGs. Measured iron transport rates were 4.8 g/hr/100 MWe at pH 9.8 and 2.8 g/hr/100 MWe at 9.3, respectively. Removal of corrosion products through SG blowdown is very limited. Its removal efficiency at the higher pH plant was in the neighborhood of 10 %. In one of the Korea Nuclear Units, a large amount of sludge piles were found in the middle of tube bundles especially on the cold leg side. Damaged tubes were identified by the multi-frequency eddy current tests and plugged later during the refueling period. Intermittent blowdown-rate increase was tried to enhance ionic impurity removal through SG blowdown. Even though it was not effective against Na, removal other impurity was improved, resulting in prolonged condensate polisher operation periods by 1 - 2 days. Two-bed polisher design, a cation bed followed by a mixed bed, was chosen for future PWR plants to enhance corrosion product filtering capability of the polishers. Condensate pump discharge polishing and divided hot well polishing methods are currently in consideration. (Nogami, K.)

  10. Polish Cartographical Review

    Directory of Open Access Journals (Sweden)

    Nedjeljko Frančula

    2017-07-01

    Full Text Available The Polish Cartographical Review (PCR journal has been published in English four times a year since 2015. The journal is in open access and it is published by De Gruyter Open. It is edited by Polish scientists in collaboration with international experts.

  11. Improving the thermodynamic efficiency of steam turbine condensers with partial tube replacement and an advanced tube bundle design

    International Nuclear Information System (INIS)

    Drosdziok, A.; Zorner, W.

    1989-01-01

    Many different problems have been experienced with power plant condensers all over the world. It has become apparent that plant availability and cost-effectiveness are significantly influenced by the thermodynamic design of the condensers and the materials selected. This paper reports that by refitting older condensers in operating plants it has proven possible to improve thermodynamic efficiency by changing the tube bundle design. In conjunction with the replacement of the cooper-bearing tubing in these condensers, which became necessary because of the introduction of high AVT (All Volatile Treatment) conditioning in the secondary circuit, it has generally been possible to fulfil the requirements imposed on the condensers without a deterioration of plant efficiency. By experience, best results have been obtained by replacing the condenser bundle with an advanced tube bundle design. Apart from solving all problems, this further improves the thermodynamic efficiency of the condensers. In nuclear power plants constructed by the Siemens KWU Group the condensers are tailored to present-day requirements

  12. Polish-German bilingualism at school. A Polish perspective

    Directory of Open Access Journals (Sweden)

    Pulaczewska, Hanna

    2014-03-01

    Full Text Available This article presents the institutional frames for the acquisition of Polish literacy skills in Germany and the maintenance of Polish-German bilingualism after the repatriation of bilingual children to Poland. These processes are examined in the context of recent developments in the European domestic job market. While the European Union has placed proficiency in several languages among its educational objectives, and foreign languages have been made obligatory school subjects in all member countries, the potential advantages of internal European migrations for producing high-proficiency bilinguals are being ignored. Bilingualism resulting from migration and biculturalism enjoys little social prestige in the host countries. In Germany, there is significant regional variation in how school authorities react to challenges posed by the presence of minority languages. In many cases, the linguistic potential of many second-generation migrants and re-emigrants gets largely wasted because of lacking interest and incentives from German and Polish institutions alike.

  13. Plant identification credibility in ethnobotany: a closer look at Polish ethnographic studies

    Directory of Open Access Journals (Sweden)

    Łuczaj Łukasz J

    2010-12-01

    Full Text Available Abstract Background This paper is an attempt to estimate the percentage of erroneously identified taxa in ethnographic studies concerning the use of plants and to propose a code for recording credibility of identification in historical ethnobotany publications. Methods A sample of Polish-language ethnobotanical literature (45 published sources from 1874-2005 and four collections of voucher specimens (from 1894-1975 were analyzed. Errors were detected in the publications by comparing the data with existing knowledge on the distribution of plant names and species ranges. The voucher specimens were re-examined. A one-letter code was invented for quick identification of the credibility of data published in lists of species compiled from historical or ethnographic sources, according to the source of identification: voucher specimen, Latin binominal, botanical expert, obvious widespread name, folk name, mode of use, range, physical description or photograph. To test the use of the code an up-to-date list of wild food plants used in Poland was made. Results A significant difference between the ratio of mistakes in the voucher specimen collections and the ratio of detectable mistakes in the studies without herbarium documentation was found. At least 2.3% of taxa in the publications were identified erroneously (mean rate was 6.2% per publication, and in half of these mistakes even the genus was not correct. As many as 10.0% of voucher specimens (on average 9.2% per collection were originally erroneously identified, but three quarters of the identification mistakes remained within-genus. The species of the genera Thymus, Rumex and Rubus were most often confused within the genus. Not all of the invented credibility codes were used in the list of wild food plants, but they may be useful for other researchers. The most often used codes were the ones signifying identification by: voucher specimen, botanical expert and by a common name used throughout the

  14. Plant identification credibility in ethnobotany: a closer look at Polish ethnographic studies.

    Science.gov (United States)

    Łuczaj, Łukasz J

    2010-12-17

    This paper is an attempt to estimate the percentage of erroneously identified taxa in ethnographic studies concerning the use of plants and to propose a code for recording credibility of identification in historical ethnobotany publications. A sample of Polish-language ethnobotanical literature (45 published sources from 1874-2005) and four collections of voucher specimens (from 1894-1975) were analyzed. Errors were detected in the publications by comparing the data with existing knowledge on the distribution of plant names and species ranges. The voucher specimens were re-examined.A one-letter code was invented for quick identification of the credibility of data published in lists of species compiled from historical or ethnographic sources, according to the source of identification: voucher specimen, Latin binominal, botanical expert, obvious widespread name, folk name, mode of use, range, physical description or photograph. To test the use of the code an up-to-date list of wild food plants used in Poland was made. A significant difference between the ratio of mistakes in the voucher specimen collections and the ratio of detectable mistakes in the studies without herbarium documentation was found. At least 2.3% of taxa in the publications were identified erroneously (mean rate was 6.2% per publication), and in half of these mistakes even the genus was not correct. As many as 10.0% of voucher specimens (on average 9.2% per collection) were originally erroneously identified, but three quarters of the identification mistakes remained within-genus.The species of the genera Thymus, Rumex and Rubus were most often confused within the genus.Not all of the invented credibility codes were used in the list of wild food plants, but they may be useful for other researchers. The most often used codes were the ones signifying identification by: voucher specimen, botanical expert and by a common name used throughout the country. The results of this study support the rigorous use

  15. Molecular fossils in Cretaceous condensate from western India

    Science.gov (United States)

    Bhattacharya, Sharmila; Dutta, Suryendu; Dutta, Ratul

    2014-06-01

    The present study reports the biomarker distribution of condensate belonging to the early Cretaceous time frame using gas chromatography-mass spectrometry (GC-MS). The early Cretaceous palaeoenvironment was inscribed into these molecular fossils which reflected the source and conditions of deposition of the condensate. The saturate fraction of the condensate is characterized by normal alkanes ranging from n-C9 to n-C29 (CPI-1.13), cycloalkanes and C14 and C15 sesquiterpanes. The aromatic fraction comprises of naphthalene, phenanthrene, their methylated derivatives and cyclohexylbenzenes. Isohexylalkylnaphthalenes, a product of rearrangement process of terpenoids, is detected in the condensate. Several aromatic sesquiterpenoids and diterpenoids have been recorded. Dihydro- ar-curcumene, cadalene and ionene form the assemblage of sesquiterpenoids which are indicative of higher plant input. Aromatic diterpenoid fraction comprises of simonellite and retene. These compounds are also indicative of higher plants, particularly conifer source which had been a predominant flora during the Cretaceous time.

  16. Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Edward Levy; Harun Bilirgen; John DuPoint

    2011-03-31

    Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants. The report describes: (1) An expanded data base on water and acid condensation characteristics of condensing heat exchangers in coal-fired units. This data base was generated by performing slip stream tests at a power plant with high sulfur bituminous coal and a wet FGD scrubber and at a power plant firing high-moisture, low rank coals. (2) Data on typical concentrations of HCl, HNO{sub 3} and H{sub 2}SO{sub 4} in low temperature condensed flue gas moisture, and mercury capture efficiencies as functions of process conditions in power plant field tests. (3) Theoretical predictions for sulfuric acid concentrations on tube surfaces at temperatures above the water vapor dewpoint temperature and below the sulfuric acid dew point temperature. (4) Data on corrosion rates of candidate heat exchanger tube materials for the different regions of the heat exchanger system as functions of acid concentration and temperature. (5) Data on effectiveness of acid traps in reducing sulfuric acid concentrations in a heat exchanger tube bundle. (6) Condensed flue gas water treatment needs and costs. (7) Condensing heat exchanger designs and installed capital costs for full-scale applications, both for installation immediately downstream of an ESP or baghouse and for installation downstream of a wet SO{sub 2} scrubber. (8) Results of cost-benefit studies of condensing heat exchangers.

  17. Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Edward; Bilirgen, Harun; DuPont, John

    2011-03-31

    Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants. The report describes: • An expanded data base on water and acid condensation characteristics of condensing heat exchangers in coal-fired units. This data base was generated by performing slip stream tests at a power plant with high sulfur bituminous coal and a wet FGD scrubber and at a power plant firing highmoisture, low rank coals. • Data on typical concentrations of HCl, HNO{sub 3} and H{sub 2}SO{sub 4} in low temperature condensed flue gas moisture, and mercury capture efficiencies as functions of process conditions in power plant field tests. • Theoretical predictions for sulfuric acid concentrations on tube surfaces at temperatures above the water vapor dewpoint temperature and below the sulfuric acid dew point temperature. • Data on corrosion rates of candidate heat exchanger tube materials for the different regions of the heat exchanger system as functions of acid concentration and temperature. • Data on effectiveness of acid traps in reducing sulfuric acid concentrations in a heat exchanger tube bundle. • Condensed flue gas water treatment needs and costs. • Condensing heat exchanger designs and installed capital costs for full-scale applications, both for installation immediately downstream of an ESP or baghouse and for installation downstream of a wet SO{sub 2} scrubber. • Results of cost-benefit studies of condensing heat exchangers.

  18. Numerical Study of Condensation Heat Exchanger Design in a Subcooled Pool: Correlation Investigation

    International Nuclear Information System (INIS)

    Lee, Hee Joon; Ju, Yun Jae; Kang, Han Ok; Lee, Tae Ho; Park, Cheon Tae

    2012-01-01

    Generally the condensation heat exchanger has higher heat transfer coefficient compared to the single phase heat exchanger, so has been widely applied to the cooling systems of energy plant. Recently vertical or horizontal type condensation heat exchangers are being studied for the application to secondary passive cooling system of nuclear plants. Lee and Lee investigated the existing condensation correlation to the experiment for heat exchanger in saturated pool. They concluded Traviss' correlation showed most satisfactory results for the heat transfer coefficient and mass flow rate in a saturated water pool. In this study, a thermal sizing program of vertical condensation heat exchanger to design, TSCON(Thermal Sizing of CONdenser) was validated with the existing experimental data of condensation heat exchanger in a subcooled pool for pure steam condensation

  19. Sewage sludge ash (SSA) from large and small incineration plants as a potential source of phosphorus - Polish case study.

    Science.gov (United States)

    Smol, Marzena; Kulczycka, Joanna; Kowalski, Zygmunt

    2016-12-15

    The aim of this research is to present the possibility of using the sewage sludge ash (SSA) generated in incineration plants as a secondary source of phosphorus (P). The importance of issues related to P recovery from waste materials results from European Union (UE) legislation, which indicated phosphorus as a critical raw material (CRM). Due to the risks of a shortage of supply and its impact on the economy, which is greater than other raw materials, the proper management of phosphorus resources is required in order to achieve global P security. Based on available databases and literature, an analysis of the potential use of SSA for P-recovery in Poland was conducted. Currently, approx. 43,000 Mg/year of SSA is produced in large and small incineration plants and according to in the Polish National Waste Management Plan 2014 (NWMP) further steady growth is predicted. This indicates a great potential to recycle phosphorus from SSA and to reintroduce it again into the value chain as a component of fertilisers which can be applied directly on fields. The amount of SSA generated in installations, both large and small, varies and this contributes to the fact that new and different P recovery technology solutions must be developed and put into use in the years to come (e.g. mobile/stationary P recovery installations). The creation of a database focused on the collection and sharing of data about the amount of P recovered in EU and Polish installations is identified as a helpful tool in the development of an efficient P management model for Poland. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Collection of Condensate Water: Global Potential and Water Quality Impacts

    KAUST Repository

    Loveless, Kolin Joseph

    2012-12-28

    Water is a valuable resource throughout the world, especially in hot, dry climates and regions experiencing significant population growth. Supplies of fresh water are complicated by the economic and political conditions in many of these regions. Technologies that can supply fresh water at a reduced cost are therefore becoming increasingly important and the impact of such technologies can be substantial. This paper considers the collection of condensate water from large air conditioning units as a possible method to alleviate water scarcity issues. Using the results of a climate model that tested data collected from 2000 to 2010, we have identified areas in the world with the greatest collection potential. We gave special consideration to areas with known water scarcities, including the coastal regions of the Arabian Peninsula, Sub-Saharan Africa and South Asia. We found that the quality of the collected water is an important criterion in determining the potential uses for this water. Condensate water samples were collected from a few locations in Saudi Arabia and detailed characterizations were conducted to determine the quality of this water. We found that the quality of condensate water collected from various locations and types of air conditioners was very high with conductivities reaching as low as 18 μS/cm and turbidities of 0. 041 NTU. The quality of the collected condensate was close to that of distilled water and, with low-cost polishing treatments, such as ion exchange resins and electrochemical processes, the condensate quality could easily reach that of potable water. © 2012 Springer Science+Business Media Dordrecht.

  1. Polish Academy of Sciences Great Dictionary of Polish [Wielki słownik języka polskiego PAN

    Directory of Open Access Journals (Sweden)

    Piotr Žmigrodzki

    2014-12-01

    Full Text Available The paper describes a lexicographical project involving the development of the newest general dictionary of the Polish language: the Polish Academy of Sciences Great Dictionary of Polish [Wielki słownik języka polskiego PAN]. The project is coordinated by the Institute of Polish Language at the Polish Academy of Sciences and carried out in collaboration with linguists and lexicographers from several other Polish academic centres. The paper offers a brief description of the genesis of the project and the scope of information included in the dictionary, the organisation of work, the life of the dictionary on the Web as well as the plans for the future.

  2. Comparative performance analysis of ice plant test rig with TiO2-R-134a nano refrigerant and evaporative cooled condenser

    Directory of Open Access Journals (Sweden)

    Amrat Kumar Dhamneya

    2018-03-01

    Full Text Available The nanoparticle is used in chillers for increasing system performance. The increasing concentration of nanoparticles (TiO2 in refrigerant increases the performances of the system due decreasing compressor work done and enhance heat transfer rate. For hot and dry climate condition, performances of air-cooled condenser minimize, and C. O. P. decreases extensively in chillers due to heat transfer rate decreases in the condenser. In the condenser, nano-refrigerants are not cool at the desired level, and the system was faulty. These drawbacks of the nano-particles mixed refrigerator have promoted the research and improving heat rejection rate in the condenser. In this article, vapour compression refrigeration system coupled with evaporative cooling pad, and nano-refrigerant, for improving the performance of the system in hot & dry weather is proposed and compared experimentally. Combined evaporative cooling system and ice plant test rig have been proposed for the appropriate heat rejection offered in the condenser due to a faulty system run at high pressure. The experimental investigations revealed that the performance characteristics of the evaporatively-cooled condenser are significantly enhanced. Maximum C.O.P. increases by about 51% in the hot and dry climate condition than the normal system.

  3. Laboratory optimization tests of technetium decontamination of Hanford Waste Treatment Plant low activity waste melter off-gas condensate simulant

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, Kathryn M.L. [Savannah River Site (SRS), Aiken, SC (United States); McCabe, Daniel J. [Savannah River Site (SRS), Aiken, SC (United States)

    2015-11-01

    The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable simplified operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of glass waste.

  4. Diagnosis of condensation-induced waterhammer: Methods and background

    International Nuclear Information System (INIS)

    Izenson, M.G.; Rothe, P.H.; Wallis, G.B.

    1988-10-01

    This guidebook provides reference material and diagnostic procedures concerning condensation-induced waterhammer in nuclear power plants. Condensation-induced waterhammer is the most damaging form of waterhammer and its diagnosis is complicated by the complex nature of the underlying phenomena. In Volume 1, the guidebook groups condensation-induced waterhammers into five event classes which have similar phenomena and levels of damage. Diagnostic guidelines focus on locating the event center where condensation and slug acceleration take place. Diagnosis is described in three stages: an initial assessment, detailed evaluation and final confirmation. Graphical scoping analyses are provided to evaluate whether an event from one of the event classes could have occurred at the event center. Examples are provided for each type of waterhammer. Special instructions are provided for walking down damaged piping and evaluating damage due to waterhammer. To illustrate the diagnostic methods and document past experience, six case studies have been compiled in Volume 2. These case studies, based on actual condensation-induced waterhammer events at nuclear plants, present detailed data and work through the event diagnosis using the tools introduced in the first volume. 65 figs., 8 tabs

  5. Polish Higher Education: Intersectoral Distinctiveness

    Science.gov (United States)

    Musial, Joanna

    2014-01-01

    This study analyzes degrees of differences between the private and public sectors of Polish higher education. It finds them to be strong: Polish private institutions function very differently from Polish public institutions and these differences correspond with those found in the literature on higher education elsewhere in the world. Polish…

  6. In-stack condensible particulate matter measurement and permitting issues

    International Nuclear Information System (INIS)

    Corio, L.A.; Sherwell, J.

    1997-01-01

    Based on the results of recent epidemiological studies and assessments of the causes of visibility degradation, EPA is proposing to regulate PM2.5 emissions. PM can be classified as either filterable or condensible PM. Condensible PM includes sulfates, such as sulfuric acid. Sulfates typically account for at least half of the total dry fine PM mass in the atmosphere. Power plant SO x -based emissions make a significant contribution to ambient fine PM levels in the eastern US. Although much of this mass is derived from secondary chemical reactions in the atmosphere, a portion of this sulfate is emitted directly from stacks as condensible PM. The potential condensible PM fraction associated with coal-burning boiler emissions is somewhat uncertain. The characterization of PM emissions from these sources has been, until recently, based on in-stack filterable PM measurements only. To determine the relative magnitude of condensible PM emissions and better understand condensible PM measurement issues, a review and analysis of actual EPA Method 202 results and state-developed hybrid condensible PM methods were conducted. A review of available Method 202 results for several coal-burning boilers showed that the condensible PM, on average, comprises 60% of the total PM10. A review of recent results for state-developed measurement methods for condensible PM for numerous coal-burning boilers indicated that condensible PM accounted for, on average, approximately 49% of total PM. Caution should be exercised in the use of these results because of the seemingly unresolved issue of artifact formation, which may bias the Method 202 and state-developed methods results on the high side. Condensible PM10 measurement results and issues, and potential ramifications of including condensible PM10 emissions in the PSD permit review process are discussed. Selected power plants in Maryland are discussed as examples

  7. Financing aspects of nuclear power plant construction under Polish economic conditions

    International Nuclear Information System (INIS)

    Besant-Jones, John E.

    1999-01-01

    Within the framework of the new Polish Energy Law the different issues important far financing a programme to develop nuclear power power in Poland such as: economic competitiveness of nuclear power, financing options for nuclear power projects, managing the various risks for financing nuclear power as well as nuclear and business liability are considered. The importance of policy issues is stressed

  8. Surface Roughness and Gloss of Actual Composites as Polished With Different Polishing Systems.

    Science.gov (United States)

    Rodrigues-Junior, S A; Chemin, P; Piaia, P P; Ferracane, J L

    2015-01-01

    This in vitro study evaluated the effect of polishing with different polishing systems on the surface roughness and gloss of commercial composites. One hundred disk-shaped specimens (10 mm in diameter × 2 mm thick) were made with Filtek P-90, Filtek Z350 XT, Opallis, and Grandio. The specimens were manually finished with #400 sandpaper and polished by a single operator using three multistep systems (Superfix, Diamond Pro, and Sof-lex), one two-step system (Polidores DFL), and one one-step system (Enhance), following the manufacturer's instructions. The average surface roughness (μm) was measured with a surface profilometer (TR 200 Surface Roughness Tester), and gloss was measured using a small-area glossmeter (Novo-Curve, Rhopoint Instrumentation, East Sussex, UK). Data were analyzed by two-way analysis of variance and Tukey's test (α=0.05). Statistically significant differences in surface roughness were identified by varying the polishing systems (pGloss was influenced by the composites (pone-step system, Enhance, produced the lowest gloss for all composites. Surface roughness and gloss were affected by composites and polishing systems. The interaction between both also influenced these surface characteristics, meaning that a single polishing system will not behave similarly for all composites. The multistep systems produced higher gloss, while the one-step system produced the highest surface roughness and the lowest gloss of all.

  9. An investigation and analysis of safety issues in Polish small construction plants.

    Science.gov (United States)

    Dąbrowski, Andrzej

    2015-01-01

    The construction industry is a booming sector of the Polish economy; however, it is stigmatised by a lower classification due to high occupational risks and an unsatisfactory state of occupational safety. Safety on construction sites is compromised by small construction firms which dominate the market and have high accident rates. This article presents the results of studies (using a checklist) conducted in small Polish construction companies in terms of selected aspects of safety, such as co-operation with the general contractor, occupational health and safety documents, occupational risk assessment, organization of work, protective gear and general work equipment. The mentioned studies and analyses provided the grounds to establish the main directions of preventive measures decreasing occupational risk in small construction companies, e.g., an increase in engagement of investors and general contractors, improvement of occupational health and safety (OSH) documents, an increase in efficiency of construction site managers, better stability of employment and removal of opposing objectives between economic strategy and work safety.

  10. Flue gas condensing with heat pump; Roekgaskondensering med vaermepump

    Energy Technology Data Exchange (ETDEWEB)

    Axby, Fredrik; Pettersson, Camilla [Carl Bro Energikonsult AB, Malmoe (Sweden)

    2004-11-01

    Flue gas condensing is often both a technically and economically efficient method to increase the thermal efficiency in a plant using fuels with high moisture and/or high hydrogen content. The temperature of the return water in district heating systems in Sweden is normally 50 deg C, which gives quite high efficiency for a flue gas condenser. The flue gas after the flue gas condenser still contains energy that to some extent can be recovered by a combustion air humidifier or a heat pump. The object of this project is to technically and economically analyse flue gas condensing with heat pump. The aim is that plant owners get basic data to evaluate if a coupling between a flue gas condenser and a heat pump could be of interest for their plant. With a heat pump the district heating water can be 'sub cooled' to increase the heat recover in the flue gas condenser and thereby increase the total efficiency. The project is set up as a case study of three different plants that represent different types of technologies and sizes; Aabyverket in Oerebro, Amagerforbraending in Copenhagen and Staffanstorp district heating central. In this report a system with a partial flow through the condenser of the heat pump is studied. For each plant one case with the smallest heat pump and a total optimization regarding total efficiency and cost for investment has been calculated. In addition to the optimizations sensitivity analyzes has been done of the following parameters: Moisture in fuel; Type of heat pump; Temperature of the return water in the district heating system; and, Size of plant. The calculations shows that the total efficiency increases with about 6 % by the installation of the heat pump at a temperature of the return water in the district heating system of 50 deg C at Aabyverket. The cost for production of heat is just below 210 kr/MWh and the straight time for pay-off is 5,4 years at 250 kr/MWh in heat credit and at 300 kr/MWh in basic price for electricity. The

  11. Polish visit

    CERN Document Server

    2003-01-01

    On 6 October, Professor Michal Kleiber, Polish Minister of Science and Chairman of the State Committee for Scientific Research, visited CERN and met both the current and designated Director General, Luciano Maiani and Robert Aymar. Professor Kleiber visited the CMS and ATLAS detector assembly halls, the underground cavern for ATLAS, and the LHC superconducting magnet string test hall. Michal Kleiber (left), Polish minister of science and Jan Krolikowski, scientist at Warsaw University and working for CMS, who shows the prototypes of the Muon Trigger board of CMS.

  12. Development of computer program for the economic evaluation of the volume reduction system for the low-level radwaste

    International Nuclear Information System (INIS)

    Yang, Jin Yeong

    1994-02-01

    This study provides the basis for investigating the benefits of purchasing volume reduction equipment and includes the establishment of a volume reduction data base, the creation of the volume reduction cost analysis computer program PEEVR (Program of Economic Evaluation for the Volume Reduction), and a generic analysis designed to identify the major costs influencing the economics of the various equipment options. In treating the plant types and the wastes, this study considers that condensate polishing system is included or not in PWR and precoat condensate polishing system, deep bed condensate polishing system in BWR and the 5 waste streams, i.e., compatible trash (COTRASH), ion exchange resin (IXRESIN), concentrate liquid (CONCLIQ), filter sludge (FSLUDGE), non compatible trash (COTRASH). This study uses the PVRR and LRR methods to create cost analysis and performs sensitivity analysis for the each cost variable and shows that future burial costs increases are the major factors in the economic evaluation

  13. Chemical mechanical glass polishing with cerium oxide: Effect of selected physico-chemical characteristics on polishing efficiency

    Czech Academy of Sciences Publication Activity Database

    Janoš, P.; Ederer, J.; Pilařová, V.; Henych, Jiří; Tolasz, Jakub; Milde, D.; Opletal, T.

    2016-01-01

    Roč. 362, SEP (2016), s. 114-120 ISSN 0043-1648 R&D Projects: GA MŠk(CZ) LM2015073 Institutional support: RVO:61388980 Keywords : Chemical mechanical polishing * Ceria-based polishing powders * Polishing efficienc Subject RIV: CA - Inorganic Chemistry Impact factor: 2.531, year: 2016

  14. Design of condenser for 500 MWe pressurised heavy water reactors (PHWRs) - a case study

    International Nuclear Information System (INIS)

    Agarwal, N.K.; Subbarao, A.; Chaudhary, K.

    1996-01-01

    Condenser forms the major heat sink in the power plants. In recent years, power plant availability and performance have become great concern to the industry. The detailed design of the condenser and its associated cooling water (CW) system require careful optimisation of parameters which include material selection, cooling water flow rate, condenser surface areas, turbine exhaust pressures etc. This is required to produce a design offering maximum efficiency and reliability and minimum maintenance. The various parameters involved in condenser design are discussed. 5 refs., 1 fig

  15. Dry coolers and air-condensing units (Review)

    Science.gov (United States)

    Milman, O. O.; Anan'ev, P. A.

    2016-03-01

    The analysis of factors affecting the growth of shortage of freshwater is performed. The state and dynamics of the global market of dry coolers used at electric power plants are investigated. Substantial increase in number and maximum capacity of air-cooled condensers, which have been put into operation in the world in recent years, are noted. The key reasons facilitating the choice of developers of the dry coolers, in particular the independence of the location of thermal power plant from water sources, are enumerated. The main steam turbine heat removal schemes using air cooling are considered, their comparison of thermal efficiency is assessed, and the change of three important parameters, such as surface area of heat transfer, condensate pump flow, and pressure losses in the steam exhaust system, are estimated. It is shown that the most effective is the scheme of direct steam condensation in the heat-exchange tubes, but other schemes also have certain advantages. The air-cooling efficiency may be enhanced much more by using an air-cooling hybrid system: a combination of dry and wet cooling. The basic applied constructive solutions are shown: the arrangement of heat-exchange modules and the types of fans. The optimal mounting design of a fully shopassembled cooling system for heat-exchange modules is represented. Different types of heat-exchange tubes ribbing that take into account the operational features of cooling systems are shown. Heat transfer coefficients of the plants from different manufacturers are compared, and the main reasons for its decline are named. When using evaporative air cooling, it is possible to improve the efficiency of air-cooling units. The factors affecting the faultless performance of dry coolers (DC) and air-condensing units (ACU) and the ways of their elimination are described. A high velocity wind forcing reduces the efficiency of cooling systems and creates preconditions for the development of wind-driven devices. It is noted that

  16. Evaluation of growth and flowering of Chenopodium quinoa Willd. under Polish conditions

    Directory of Open Access Journals (Sweden)

    Krzysztof Gęsiński

    2012-12-01

    Full Text Available The material presented refers to the estimation of growth and the flowering (Chenopodium quinoa Willd. under Polish conditions. The species has been a South-American pseudocereal cultivated in the traditional form in the Andean region for over 5 thousand years. Its advantage, apart from low soil and climate requirements, is that it shows high nutritive value. The Chenopodium quinoa protein is especially valuable with its amino acid composition which is better balanced than that of wheat or maize. It shows a better share of egzogenic aminoacids. Field examinations were carried out in 1999-2001 at the Experiment Station of Cultivar Testing at Chrząstowo. The experiment involved two cultivars from two various growing regions: America and Europe. Analyses were made to include development stages, plant growth dynamics, inflorescences development dynamics, inflorescence habit and flowering. Differences were recorded in the growth and development models of the cultivars researched. The European cultivar had a short compact inflorescence with a short flowering period, reaching 120 cm. American cultivar plants were high (160 cm; they showed a slower continuous growth, loose big-in-size inflorescence, and a long period of flowering. The plants ended their growing season over the flowering stage or seed formation. The adequate growth, the course of flowering and, as a result, a stable yielding of the European cultivar make the group suitable for the cultivation under Polish conditions. This breeding group should also be the parent material for the cultivation of the Polish cultivar of Chenopodium quinoa.

  17. COMMIX-PPC: A three-dimensional transient multicomponent computer program for analyzing performance of power plant condensers

    International Nuclear Information System (INIS)

    Chien, T.H.; Domanus, H.M.; Sha, W.T.

    1993-02-01

    The COMMIX-PPC computer pregrain is an extended and improved version of earlier COMMIX codes and is specifically designed for evaluating the thermal performance of power plant condensers. The COMMIX codes are general-purpose computer programs for the analysis of fluid flow and heat transfer in complex Industrial systems. In COMMIX-PPC, two major features have been added to previously published COMMIX codes. One feature is the incorporation of one-dimensional equations of conservation of mass, momentum, and energy on the tube stile and the proper accounting for the thermal interaction between shell and tube side through the porous-medium approach. The other added feature is the extension of the three-dimensional conservation equations for shell-side flow to treat the flow of a multicomponent medium. COMMIX-PPC is designed to perform steady-state and transient. Three-dimensional analysis of fluid flow with heat transfer tn a power plant condenser. However, the code is designed in a generalized fashion so that, with some modification, it can be used to analyze processes in any heat exchanger or other single-phase engineering applications. Volume I (Equations and Numerics) of this report describes in detail the basic equations, formulation, solution procedures, and models for a phenomena. Volume II (User's Guide and Manual) contains the input instruction, flow charts, sample problems, and descriptions of available options and boundary conditions

  18. Mechanical vapor compression Desalination plant at Trombay

    International Nuclear Information System (INIS)

    Adak, A.K.; Kishore, G.; Srivastava, V.K.; Tewari, P.K.

    2007-01-01

    Desalination plants based on Mechanical Vapour Compression (MVC) technology are inherently the most thermodynamically efficient. The thermodynamic efficiency of the MVC process is derived from the application of the heat pump principle. A single unit of two-effect MVC desalination pilot plant of capacity 50 m3/day has recently been commissioned at Trombay, Mumbai. The desalination unit is very compact and unique of its kind in the seawater desalination technologies and is being operated by using electricity only. Horizontal tube thin film spray desalination evaporators are used for efficient heat transfer. It is suitable for a site, where feed water is highly saline and condenser cooling water is absent and where a thermal heat source is not available. The unit produces high quality water, nearly demineralized (DM) quality directly from seawater. There is no need of polishing unit and product water can be utilized directly as make up of boiler feed and for other high quality process water requirements in the industries. This paper includes the design and highlights the technical features of this unit. (author)

  19. Development of a new generation of ion exchange resin for nuclear and fossil power plant

    International Nuclear Information System (INIS)

    Tsuzuki, Shintaro; Tagawa, Hidemi; Yamashita, Futoshi; Okamoto, Ryutaro

    2008-01-01

    It is required to maintain water quality supplied to steam generator to the water designed based on its water chemistry in order to keep the sound operation of nuclear power plants or fossil power plants. Condensate Polishing Plant (CPP) is installed for removing ions in the water which uses a mixed bed of cation exchange resin and anion exchange resin. We have developed new generation of CPP resin. The product is a unique combination of super high exchange capacity cation exchange resin and high fouling resistant anion exchange resin. The CPP resin has been used in many power plants. Amberjet 1006 was developed as a cation exchange resin with high oxidative stability, high operational capacity and New IRA900CP was developed as an anion exchange resin with high fouling resistant to leachables released out of cation exchange resin by oxidative degradation over the service period. The novel CPP resin was first used in 2000 and has now been used in many power plants in Japan. The CPP resin has been giving excellent quality of water. (author)

  20. Analysis of the biological and molecular variability of the Polish isolates of Tomato black ring virus (TBRV).

    Science.gov (United States)

    Rymelska, N; Borodynko, N; Pospieszny, H; Hasiów-Jaroszewska, B

    2013-10-01

    Tomato black ring virus (TBRV) is an important pathogen infecting many plant species worldwide. The biological and molecular variability of the Polish isolates of TBRV was analyzed. The analysis was performed based on the symptoms induced by various isolates on test plant species as well as on phylogenetic relationships between isolates. Isolates differed in their host range and symptomatology. In addition, genetic variation among isolates was characterized by restriction fragment length polymorphism analysis and confirmed by sequencing. The phylogenetic analysis revealed that the Polish isolates differ from each other and do not form a monophyletic cluster. Finally, we identified and analyzed sequences of defective RNA forms arising from the TBRV genome.

  1. A CFD study of wave influence on film steam condensation in the presence of non-condensable gas

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xianmao, E-mail: xm-wang11@mails.tsinghua.edu.cn [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Chang, Huajian, E-mail: changhj@tsinghua.edu.cn [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Corradini, Michael, E-mail: corradini@engr.wisc.edu [Department of Engineering Physics, University of Wisconsin-Madison, 1500 Engineering Drive, Madison, WI 53706 (United States)

    2016-08-15

    Highlights: • A condensation model is incorporated in the ANSYS FLUENT. • Different turbulence models are evaluated for flows over wavy surfaces. • Wavy surfaces with and without moving velocities are used to model the wave. • Various wavy surfaces with different wave heights and wavelengths are selected. • Wave influence on film steam condensation is investigated. - Abstract: Steam condensation plays an important role in removing heat from the containment of a nuclear plant during postulated accidents. However, due to the presence of non-condensable gases such as air and hydrogen in the containment, the condensation rate can decrease dramatically. Under certain conditions, the condensate film on the cold containment walls can affect the overall heat transfer rate. The wavy interface of the condensate film is a factor and is usually believed to enhance the condensation rate, since the waves can both increase the interfacial area and disturb the non-condensable gas boundary layer. However, it is not clear how to properly account for this factor and what is its quantitative influence in experiments. In this work, a CFD approach is applied to study the wave effects on film condensation in the presence of non-condensable gas. Wavy surfaces with and without moving velocities are used to replace the wavy interface of the falling film. A condensation model is incorporated in the ANSYS FLUENT simulation and a realizable k–ε turbulence model is applied. Various wavy surfaces with different wave heights and wavelengths are selected to conduct numerical experiments with a wide range of gas velocities. The results show that the wave structure can enhance condensation rate up to ten percent mainly due to the alteration of local flow structures in the gas phase. The increments of the condensation rate due to the wavy interface can vary with different gas velocities. The investigation shows that a multiplication factor accounts for the wave effects on film

  2. Titanium condenser tubes--problems and their solutions for wider application to large surface condensers

    Energy Technology Data Exchange (ETDEWEB)

    Sato, S; Sugiyama, Y; Nagata, K; Namba, K; Shimono, M

    1978-01-01

    To meet the demand for high reliability condensers for thermal and nuclear power plants, especially for PWR plants, the condensers installed entirely with titanium tubes have been investigated and used. Some difficulties from conventional copper alloy tubes exist. Further investigations are necessary on three items: (1) tube vibration; (2) joining tubes to tube plate; (3) fouling (bio-fouling) control. Literature survey on the tube vibration suggests that the probability of tube vibration due to decreased stiffness of titanium tubes in comparison with conventional copper alloy tubes can be decreased by designing the proper span length between supports. Experiments on seal welding of tubes to a tube plate have successfully proved that pulsed TIG arc welding is applicable to get reliable and strong joints, even on site, by suitable countermeasures. Experiments on the fouling (bio-fouling) of titanium tubes in marine application reveal that the increased fouling of titanium tubes could be controlled by proper application of sponge ball cleaning.

  3. Condensed tannins: Quinone methide intermediates in procyanidin synthesis

    Science.gov (United States)

    Richard W. Hemingway; L. Y. Foo

    1983-01-01

    Proanthocyanidins (condensed tanruns) are widely distributed in plants and are found in sufficiently high concentration in some tree barks to encourage their industrial utilization. These polymers consist of flavanoid units linked through the C-4 of the pyran ring to the C-6 or C-8 carbons of the aromatic A-ring. Recent advances in the chemistry of condensed tannins...

  4. Condensation model for the ESBWR passive condensers

    International Nuclear Information System (INIS)

    Revankar, S. T.; Zhou, W.; Wolf, B.; Oh, S.

    2012-01-01

    In the General Electric's Economic simplified boiling water reactor (GE-ESBWR) the passive containment cooling system (PCCS) plays a major role in containment pressure control in case of an loss of coolant accident. The PCCS condenser must be able to remove sufficient energy from the reactor containment to prevent containment from exceeding its design pressure following a design basis accident. There are three PCCS condensation modes depending on the containment pressurization due to coolant discharge; complete condensation, cyclic venting and flow through mode. The present work reviews the models and presents model predictive capability along with comparison with existing data from separate effects test. The condensation models in thermal hydraulics code RELAP5 are also assessed to examine its application to various flow modes of condensation. The default model in the code predicts complete condensation well, and basically is Nusselt solution. The UCB model predicts through flow well. None of condensation model in RELAP5 predict complete condensation, cyclic venting, and through flow condensation consistently. New condensation correlations are given that accurately predict all three modes of PCCS condensation. (authors)

  5. Synchronous Condenser Allocation for Improving System Short Circuit Ratio

    DEFF Research Database (Denmark)

    Jia, Jundi; Yang, Guangya; Nielsen, Arne Hejde

    2018-01-01

    With converter-based renewable energy sources increasingly integrated into power systems and conventional power plants gradually phased out, future power systems will experience reduced short circuit strength. The deployment of synchronous condensers can serve as a potential solution. This paper...... presents an optimal synchronous condenser allocation method for improving system short circuit ratio at converter point of common coupling using a modified short circuit analysis approach. The total cost of installing new synchronous condensers is minimized while the system short circuit ratios...

  6. Drainage control and diffusion resistance in dropwise condensation in a compact heat exchanger

    NARCIS (Netherlands)

    Grooten, M.H.M.

    2011-01-01

    Condensation of a vapor in the presence of non-condensable gas occurs frequently in process industry. For example in compact condensers for heat recovery, in extraction of toxic components from exhaust gases, in cooling systems of nuclear power plants, seawater desalination systems, air conditioning

  7. The reaction of Polish market to last year's changes on international coke and steel market

    Energy Technology Data Exchange (ETDEWEB)

    Czornik, G.; Gabriel, D. [Polski Koks S.A. (Poland)

    2004-07-01

    The presentation, outlined in 16 slides/overheads, discussed the following: Poland's position in the world market; the Polish coking industry and the world coke and steel industry; the reaction of Polish coke plants; the effect of the increase in coke prices; ownership changes in Poland's coking industry scenarios for the future; the role of Polski Koks in Poland's coking industry; and sales and exports of coke by Polski Koks.

  8. Assessment of severe accident prevention and mitigation features: PWR, ice-condenser containment design

    International Nuclear Information System (INIS)

    Hsu, C.J.; Perkins, K.R.; Luckas, W.J.; Fitzpatrick, R.G.; Cho, N.; Lehner, J.R.; Pratt, W.T.; Eltawila, F.; Maly, J.A.

    1988-07-01

    Plant features and operator actions which have been found to be important in either preventing and mitigating severe accidents in PWRs with ice-condenser containments have been identified. Thus features and actions were developed from insights derived from reviews of risk assessments performed specifically for the Sequoyah plant and from assessments of other relevant studies. Accident sequences that dominate the core-damage frequency and those accident sequences that are of potentially high consequence were identified. Vulnerabilities of the ice-condenser containment to sever accident containment loads were also identified. In addition, those features of a PWR with an ice-condenser containment, which are important for preventing core damage and are available for mitigating fission-product release to the environment were identified. This report is issued to provide focus to an analyst examining an individual plant. The report calls attention to plant features and operator actions and provides a list of deterministic attributes for assessing those features and actions found to be helpful in reducing the overall risk for Sequoyah and other PWRs with ice-condenser containments. Thus, the guidance is offered as a resource in examining the subject plant to determine if the same, or similar, plant features and operator actions will be of value in reducing overall plant risk. This report is intended to serve solely as guidance. 14 tabs

  9. A Method to Preclude Moisture Condensation in Plated Tissue Cultures

    Science.gov (United States)

    Alex M. Diner

    1992-01-01

    Excessive condensate normally accumulates in in vitro-illuminated petri dishes containing plant tissue cultures, causing avariety of problems. A dark-colored rubber net-mesh placed over the petri dishes prevented such condensation, even when charcoal-supplemented media are used under high light intensity in a growth chamber.

  10. Comparison of condensation correlations in CATHARE for modelling isolation condenser experiment

    International Nuclear Information System (INIS)

    Sorjonen, J.; Kalli, H.

    1996-01-01

    CATHARE is a thermal-hydraulic computer code developed at the Centre d'Etudes Nucleaires de Grenoble (CENG) for nuclear power plant safety analysis. Behaviour of a new Cathare condensation correlation have been studied. The code has been applied to Isolation Condenser (IC) experiment conducted in PIPER-ONE facility. PIPER-ONE simulates a General Electric BWR-6 with volume and height scaling ratios 1/2200 and 1/1, respectively. The facility is installed at Dipartimento di Costruzioni Meccaniche e Nucleari of Pisa University. The facility was equipped with an once-through heat exchanger immersed in a pool of ambient temperature water, installed roughly 10 m above the core, in the aim to reproduce qualitatively the phenomenologies expected for Isolation Condenser in the Simplified BWR (SBWR). Experiment PO-IC-02 included two subsequent power levels with initial pressure of 5.1 MPa. The IC was active during the whole experiment except in the time period between the two different power levels. A previous calculation of above mentioned experiment by Cathare2 V1.3E showed some lacks in the condensation correlation of the code. A new correlation has been developed in Centre d'Etudes Nucleaires de Grenoble (CENG). The new calculation of the PO-IC-02 experiment by Cathare2 Vl.3U 1 with the new correlation gave results consistent with the experiment in the condensing zone of the IC. Also the overall pressure trend was reproduced with estimated heat losses to the environment. A comparison with previously obtained Relap5/Mod3. 1 results is also shown in the present document. (author) (18 refs.)

  11. Effect of Mixed Working Fluid Composition on Binary Cycle Condenser Heat Transfer Coefficients

    Energy Technology Data Exchange (ETDEWEB)

    Dan Wendt; Greg Mines

    2011-10-01

    Effect of Mixed Working Fluid Composition on Binary Cycle Condenser Heat Transfer Coefficients Dan Wendt, Greg Mines Idaho National Laboratory The use of mixed working fluids in binary power plants can provide significant increases in plant performance, provided the heat exchangers are designed to take advantage of these fluids non-isothermal phase changes. In the 1980's testing was conducted at DOE's Heat Cycle Research Facility (HCRF) where mixtures of different compositions were vaporized at supercritical pressures and then condensed. This testing had focused on using the data collected to verify that Heat Transfer Research Incorporated (HTRI) codes were suitable for the design of heat exchangers that could be used with mixtures. The HCRF data includes mixture compositions varying from 0% to 40% isopentane and condenser tube orientations of 15{sup o}, 60{sup o}, and 90{sup o} from horizontal. Testing was performed over a range of working fluid and cooling fluid conditions. Though the condenser used in this testing was water cooled, the working fluid condensation occurred on the tube-side of the heat exchanger. This tube-side condensation is analogous to that in an air-cooled condenser. Tube-side condensing heat transfer coefficient information gleaned from the HCRF testing is used in this study to assess the suitability of air-cooled condenser designs for use with mixtures. Results of an air-cooled binary plant process model performed with Aspen Plus indicate that that the optimal mixture composition (producing the maximum net power for the scenario considered) is within the range of compositions for which data exist. The HCRF data is used to assess the impact of composition, tube orientation, and process parameters on the condensing heat transfer coefficients. The sensitivity of the condensing coefficients to these factors is evaluated and the suitability of air-cooled condenser designs with mixtures is assessed. This paper summarizes the evaluation

  12. Contribution to the study of unsteady condensation in transonic flow

    International Nuclear Information System (INIS)

    Collignan, B.; Laali, A.R.

    1993-12-01

    The aim of this thesis is the study of transonic steam flows with condensation, especially at high pressure. This study includes a numerical part an experimental one. The modelling has consisted of introducing a spontaneous condensation model in a one-dimensional Euler code using steam-water thermodynamic tables. Calculations, performed with this code, are in good agreement with experimental results at low pressure. The experimental study has been undertaken on a high pressure experimental loop installed at the Bugey nuclear power plant. We have studied steam flows in nozzles. The results obtained show that a partial heterogeneous condensation occurs in these flows. This proportion is stronger if the expansion rate of the flow is low and if the inlet pressure is high. However, a correction factor is obtained for high pressure nucleation rate model from experimental results. No unsteady condensation has been observed for flows between 15 bars and 50 bars with the steam available at Bugey power plant. (authors). figs., 71 refs., 6 annexes

  13. Laboratory Optimization Tests of Technetium Decontamination of Hanford Waste Treatment Plant Direct Feed Low Activity Waste Melter Off-Gas Condensate Simulant

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-12-23

    The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable less integrated operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of glass waste.

  14. Condensation on Slippery Asymmetric Bumps

    Science.gov (United States)

    Park, Kyoo-Chul; Kim, Philseok; Aizenberg, Joanna

    2016-11-01

    Controlling dropwise condensation by designing surfaces that enable droplets to grow rapidly and be shed as quickly as possible is fundamental to water harvesting systems, thermal power generation, distillation towers, etc. However, cutting-edge approaches based on micro/nanoscale textures suffer from intrinsic trade-offs that make it difficult to optimize both growth and transport at once. Here we present a conceptually different design approach based on principles derived from Namib desert beetles, cacti, and pitcher plants that synergistically couples both aspects of condensation and outperforms other synthetic surfaces. Inspired by an unconventional interpretation of the role of the beetle's bump geometry in promoting condensation, we show how to maximize vapor diffusion flux at the apex of convex millimetric bumps by optimizing curvature and shape. Integrating this apex geometry with a widening slope analogous to cactus spines couples rapid drop growth with fast directional transport, by creating a free energy profile that drives the drop down the slope. This coupling is further enhanced by a slippery, pitcher plant-inspired coating that facilitates feedback between coalescence-driven growth and capillary-driven motion. We further observe an unprecedented six-fold higher exponent in growth rate and much faster shedding time compared to other surfaces. We envision that our fundamental understanding and rational design strategy can be applied to a wide range of phase change applications.

  15. A Study on Condensation Heat Transfer at the Exterior Surface of S.A.M. Coated Titanium Tube Using in Steam Condensers

    Energy Technology Data Exchange (ETDEWEB)

    Im, Sung-Gu; Lee, Sang-Hyup; Ji, Dae-Yun; Park, Hyun-Gyu; Lee, Kwon-Yeong [Handong Global University, Pohang (Korea, Republic of)

    2016-10-15

    Condensation occurs when the temperature of a steam is reduced below its saturation temperature. There exist two forms of condensation on cooling surface: dropwise, and film condensations. Usually, dropwise condensation has a better heat transfer performance than film condensation, but it has limit of short period. Ma et al. executed heat transfer experiment in dropwise condensation with non-condensable gas, and studied how the amount of air and pressure difference affect condensation heat transfer coefficient. The more non-condensable gas exist, the condensation heat transfer coefficient is decreased. As a result, surface modified brass tube and stainless tube showed higher condensation heat transfer coefficient as much as 1.3 and 1.4 times comparing with their bare tubes in 70 kPa vacuum condition respectively. Most of power plants use sea water as coolant, so the surface of metal tubes could be corroded by the coolant. We had researched an experimental study related to condensation heat transfer on surface modified titanium tube. Our experimental facility was designed to show how two kinds of tube's heat transfer performances are different in a same condition. We changed the range of saturation pressure and coolant flow rate to observe tube's performance change. When saturation pressure and coolant flow rate increase, overall heat transfer coefficients were increased. When residue of non-condensable gases was decreased, the overall heat transfer coefficients were increased. S.A.M. coated tube's overall heat transfer coefficients were lower than those of bare tube, because the droplets didn't have a tendency of frequently falling down.

  16. Disposal of aqueous condensate from high efficiency gas boilers

    Energy Technology Data Exchange (ETDEWEB)

    Hardwick, G J; Pattison, J R

    1984-01-01

    If highly efficient gas-fired condensing heating appliances are installed in Britain, the aqueous condensate produced can be conveniently run into existing sewage drains. The part of the drainage system that is most vulnerable to corrosion from the mildly acid condensate is that portion adjacent to the domestic premises. The tests described indicate that this is not at risk and the only precaution that might be considered necessary is to avoid running the condensate over galvanized drain covers in order to prevent unsightly staining. Water authorities in Britain and detailed studies in the US and Holland confirm that the condensate - after dilution by domestic waste, sewage, and rainwater - would be harmless to municipal sewage systems and would not, either in volume or chemical composition, affect the working of existing sewage treatment plants.

  17. Strength analyses of the bubbler condenser structure of WWER-440 model 213 nuclear power plants. Reference plant: Bohunice V2 (Slovakia). Report of the IAEA Technical Co-operation Project RER/9/004 on evaluation of safety aspects of WWER-440 model 213 nuclear power plants

    International Nuclear Information System (INIS)

    1995-06-01

    This publication addresses the topic of mechanical strength of the bubbler condenser applied in the WWER-440 model 213 plants and is intended to assist WWER-440/213 operators in the re-assessment of the bubbler condenser performance. It is hoped that it will also be useful to anyone working in the field of WWER safety, and in particular to experts planning, executing or reviewing studies related to the subject. Refs, figs and tabs

  18. Strength analyses of the bubbler condenser structure of WWER-440 model 213 nuclear power plants. Reference plant: Bohunice V2 (Slovakia). Report of the IAEA Technical Co-operation Project RER/9/004 on evaluation of safety aspects of WWER-440 model 213 nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-06-01

    This publication addresses the topic of mechanical strength of the bubbler condenser applied in the WWER-440 model 213 plants and is intended to assist WWER-440/213 operators in the re-assessment of the bubbler condenser performance. It is hoped that it will also be useful to anyone working in the field of WWER safety, and in particular to experts planning, executing or reviewing studies related to the subject. Refs, figs and tabs.

  19. High-power condensation turbine application to district heating

    International Nuclear Information System (INIS)

    Virchenko, M.A.; Arkad'ev, B.A.; Ioffe, V.Yu.

    1982-01-01

    In general outline the role of condensation turbines in NPP district heating is considered. The expediency of expansion of central heating loading of turbines of operating as well as newly designed condensation power plants on the basis of the WWER-1000-type reactors is shown. The principle heat flowsheet of the 1000 MW power turbine is given. An advantage in using turbines with uncontrolled steam bleeding is pointed out [ru

  20. BIOGAS - is it chance or risk for the Polish gas industry?

    International Nuclear Information System (INIS)

    Witek, M.

    2008-01-01

    This paper presents the present state and some aspects of strategy development concerning Polish biogas plants. The paper focuses on the biogas plants supplied by agricultural raw materials and its biogas production potential. A perspective of production and usage of bio methane in Poland was discussed. An example of commercial agricultural biogas plant connected with cogeneration and natural gas production in local community in Austria was presented. A possibility of financial support of bio methane projects by various programs of European Union in years 2007-2013 was analyzed. Special attention in analysis was given to perspective of possible bio methane production in Poland. (author)

  1. Radionuclide release calculations for selected severe accident scenarios. PWR, ice condenser design

    Energy Technology Data Exchange (ETDEWEB)

    Denning, R S; Gieseke, J A; Cybulskis, P; Lee, K W; Jordan, H; Curtis, L A; Kelly, R F; Kogan, V; Schumacher, P M

    1986-07-01

    This report presents results of analyses of the environmental releases of fission products (source terms) for severe accident scenarios in a pressurized water reactor with an ice-condenser containment. The analyses were performed to support the Severe Accident Risk Reduction/Risk Rebaselining Program (SARRP) which is being undertaken for the U.S. Nuclear Regulatory Commission by Sandia National Laboratories. In the SARRP program, risk estimates are being generated for a number of reference plant designs. The Sequoyah Plant has been used in this study as an example of a PWR ice-condenser plant. (author)

  2. The tourism attractiveness of Polish libraries

    OpenAIRE

    Miedzińska, Magdalena; Tanaś, Sławoj

    2009-01-01

    The aim of the article is to draw the reader's attention to the tourism attractiveness of renowned Polish libraries. These have attained a tourism function due to tourism exploration and penetration, but remain in the shadow of other Polish cultural assets. The article outlines the historical geography of Polish libraries, an analysis of tourism assets and an attempt to classify and catalogue libraries in Poland.

  3. An Experimental Study of the Dropwise Condensation on Physically Processed Surface

    International Nuclear Information System (INIS)

    Choi, Jaeyoung; Chang, Soonheung; Watanabe, N.; Sambuichi, T.; Shiota, D.; Aritomi, M.

    2013-01-01

    Recent research by Kawakubo et al. derived empirical condensation heat transfer correlation suitable for wider range of operating condition in presence of non-condensable gas. However, their proposals of PCCS are focused on plane tube surface. To design better PCCS heat exchanger with high heat transfer coefficient new treatment on condensation surface can be considered in order to maintain dropwise condensation, the heat transfer coefficient of which has an order of magnitude larger than those of film condensation. Advanced research measure dropwise condensation heat transfer coefficient of Au and Cr coated surface based on number of droplet and droplet growth rate. However, coated surface is not desirable in power plant due to its duration of few years. On the other hand, physical processing (micro holes and patterns) on stainless steel and titanium surface is expected to perform better heat transfer, also is durable for the whole reactor lifetime. Since there is no published research about dropwise condensation for physically processed surface on SUS and Ti, the purposes of this research are to measure the condensation heat transfer coefficient and analyze its mechanism of enhanced heat transfer of treated SUS and Ti commonly used to nuclear plant. In the comparison of theoretical equation and experiment, it shows same result that heat transfer coefficient is proportional to maximum droplet diameter power to -0.321. Moreover, in the comparison of bare and processed surface, heat transfer coefficient decreases in processed surface

  4. Heat transfer from a high temperature condensable mixture

    International Nuclear Information System (INIS)

    Chan, S.H.; Cho, D.H.; Condiff, D.W.

    1978-01-01

    A new development in heat transfer is reported. It is concerned with heat transfer from a gaseous mixture that contains a condensable vapor and is at very high temperature. In the past, heat transfer associated with either a condensable mixture at low temperature or a noncondensable mixture at high temperature has been investigated. The former reduces to the classical problem of fog formation in, say, atmosphere where the rate of condensation is diffusion controlled (molecular or conductive diffusions). In the presence of noncondensable gases, heat transfer to a cooler boundary by this mechanism is known to be drastically reduced. In the latter case, where the high temperature mixture is noncondensable, radiative transfer may become dominant and a vast amount of existing literature exists on this class of problem. A fundamentally different type of problem of relevance to recent advances in open cycle MHD power plants and breeder reactor safety is considered. In the advanced coal-fired power plant using MHD as a topping cycle, a condensable mixture is encountered at temperatures of 2000 to 3000 0 . Condensation of the vaporized slag and seed materials at such a high temperature can take place in the MHD generator channel as well as in the radiant boiler. Similarly, in breeder reactor accident analyses involving hypothetical core disruptive accidents, a UO 2 vapor mixture at 400 0 K or higher is often considered. Since the saturation temperature of UO 2 at one atmosphere is close to 4000 0 K, condensation is also likely at a very high temperature. Accordingly, an objective of the present work is to provide an understanding of heat transfer and condensation mechanics insystems containing a high temperature condensable mixture. The results of the study show that, when a high temperature mixture is in contact with a cooler surface, a thermal boundary layer develops rapidly because of intensive radiative cooling from the mixture

  5. Fluid selection and parametric analysis on condensation temperature and plant height for a thermogravimetric heat pump

    International Nuclear Information System (INIS)

    Najafi, Behzad; Obando Vega, Pedro; Guilizzoni, Manfredo; Rinaldi, Fabio; Arosio, Sergio

    2015-01-01

    The Thermogravimetric Heat Pump (TGHP) is a non-conventional system, implementing a reverse cycle, the main difference of which from the usual vapor compression (Rankine) cycle is a quasi-isothermal compression of the working fluid by a high heat capacity carrier fluid. Previous studies showed that employing HFC134a or PF5050 as working fluids may be promising in terms of thermodynamic performance, though the corresponding required plant heights confine its application to tall buildings (from minimum height of 10–12 storeys to skyscrapers). Accordingly, an investigation has been carried out in the present study in order to determine a group of fluids which allow lower heights under the same input conditions. In order to investigate the performance of the system and the required plant height, operation of a 100 kW TGHP has been simulated for 17 different fluids. Accordingly, the corresponding COPs and required heights are determined and based on the achieved COPs, the optimum fluid for each range of building height is selected. The resulting plant heights range from 20 m to nearly 200 m and R245ca is shown to be the most promising fluid for the lowest plant height range. A parametric study is next carried out in order to study the effect of variations in the condensation temperature and the dimensionless plant height on the performance of the system. The obtained results demonstrate that an increase in the former from 313 K to 348 K, for almost all of the analyzed fluids, causes a reduction of around 50% in the COP. It is also shown that, almost independent of the employed fluid, the maximum values of COP are reached for a dimensionless plant height of around 1.8. Moreover, all the analyzed fluids show basically the same COP trend and, at the same operating conditions, the COP values for all fluids are within a 10% range of variation. This leads to the conclusion that the thermophysical properties of the employed fluid mainly influences the required height of

  6. Detection of paint polishing defects

    Science.gov (United States)

    Rebeggiani, S.; Wagner, M.; Mazal, J.; Rosén, B.-G.; Dahlén, M.

    2018-06-01

    Surface finish plays a major role on perceived product quality, and is the first thing a potential buyer sees. Today end-of-line repairs of the body of cars and trucks are inevitably to secure required surface quality. Defects that occur in the paint shop, like dust particles, are eliminated by manual sanding/polishing which lead to other types of defects when the last polishing step is not performed correctly or not fully completed. One of those defects is known as ‘polishing roses’ or holograms, which are incredibly hard to detect in artificial light but are clearly visible in sunlight. This paper will present the first tests with a measurement set-up newly developed to measure and analyse polishing roses. The results showed good correlations to human visual evaluations where repaired panels were estimated based on the defects’ intensity, severity and viewing angle.

  7. Tooth polishing: The current status

    Directory of Open Access Journals (Sweden)

    Madhuri Alankar Sawai

    2015-01-01

    Full Text Available Healthy teeth and gums make a person feel confident and fit. As people go about their daily routines and with different eating and drinking habits, the tooth enamel turns yellowish or gets stained. Polishing traditionally has been associated with the prophylaxis procedure in most dental practices, which patients know and expect. However, with overzealous use of polishing procedure, there is wearing of the superficial tooth structure. This would lead to more accumulation of local deposits. Also, it takes a long time for the formation of the fluoride-rich layer of the tooth again. Hence, now-a-days, polishing is not advised as a part of routine oral prophylaxis procedure but is done selectively based on the patients′ need. The article here, gives an insight on the different aspects of the polishing process along with the different methods and agents used for the same.

  8. Polish Industry and Art at CERN

    CERN Multimedia

    2000-01-01

    On 17 October 2000 the second Polish industrial and technological exhibition opened at CERN. The first one was held five years ago and nine of the companies that were present then have come back again this year. Six of those companies were awarded contracts with CERN in 1995. Three Polish officials were present at the Opening Ceremony today: Mrs Malgorzata Kozlowska, Under-secretary of State in the State Committee for Scientific Research, Mr Henryk Ogryczak, Under-secretary of State in Ministry of Economy and Prof. Jerzy Niewodniczanski, President of National Atomic Energy Agency. Professor Luciano Maiani welcomed the Polish delegation to CERN and stressed the important contribution of Polish scientists and industrialists to the work of the laboratory. Director General Luciano Maiani (back left) and head of SPL division Karl-Heinz Kissler (back right) visit the Poland at CERN exhibition… The exhibition offers Polish companies the opportunity to establish professional contacts with CERN. Nineteen companies...

  9. Activities on condensation in the presence of air and simulations of innovative nuclear power plant design

    International Nuclear Information System (INIS)

    Tanrikut, A.; Aglar, F.; Guenduez, Oe; Yesin, O.

    2001-01-01

    Nuclear energy is one of the options presently available to cope with energy needs along the forthcoming century. This challenge is requiring a tremendous effort to assure nuclear energy competence in terms of economics and safety with respect to the other potential sources of energy. In the case of water cooled power reactors, new advanced designs have been proposed of either an evolutionary or a passive type, the latter being particularly appealing for using natural forces to carry out safety functions under the most adverse conditions posed by hypothetical accidents. In this regard containment of passive reactors is to be equipped with what has been called Passive Containment Cooling Systems (PCCS). PCCS's features depend on specific designs. However, most of them share their reliance on steam condensation to mitigate long-term pressure rise in containment. New boundary conditions and device geometries prompted renewed to investigate steam condensation to eventually demonstrate PCCS's capability to meet their goals. As a result, experimental and analytical programs were launched worldwide, often on the basis of a fruitful international co-operation . Concepts of passive safety systems with no active components have been investigated for new generation light water reactors . The primary objectives of the passive design features are to simplify the design, which assures the minimized demand on operator, and to improve plant safety. To accomplish these features the operating principles of passive safety systems should be well understood by an experimental validation program. Such validation programs are also important for the assessment of advanced computer codes, which are currently used for design and licensing. In an application, the proposed advanced passive boiling water reactor design, simplified boiling water reactor (SBWR), utilizes as a main component of the passive containment cooling systems (PCCS) the isolation condenser (IC). The function of the IC is

  10. Bubbler condenser related research work. Present situation

    International Nuclear Information System (INIS)

    2001-02-01

    Intensive discussions within the OECD Support Group on 'VVER-440 Bubbler Condenser Containment Research Work' between 1991 and 1994 demonstrated the need for supplementary research work to achieve an adequate level of basic knowledge. In 1994, the European Commission (EC) asked for a specific 'VVER-440/213 Bubble Condenser Qualification Feasibility Study', which was finished early in 1996, confirming the need for additional research in this field. The Feasibility study formed the basis for the Bubble Condenser Experimental Qualification Project (BCEQ) with two separate experimental activities to be executed within the frame of the PHARE/TACIS 2.13/95 project of the European Commission. A first activity served to study the thermal-hydraulic phenomena and the associated structure dynamic interactions. This part of the project was performed at EREC, in Elektrogorsk, Russia. The design of the test facility was based on the prototypical bubbler condenser configuration for the Hungarian Paks nuclear power plant. A second activity addressed the structural integrity of certain components of the bubbler condenser steel structures under DBA-typical conditions. This part of the project was performed at VUEZ, in Levice, Slovak Republic. The design of the components of this facility was based on the structural properties of the Dukovany and/or Bohunice nuclear power plants. A third component of the BCEQ project was specified later asking for analytical studies, which should be supported by a number of small-scale separate effects tests to be performed at SVUSS, in Bechovice, Czech Republic. The main experimental and analytical results of the BCEQ test campaigns have been presented and discussed within the frame of the 4. meeting of the Technical Advisory Committee to the BCEQ (Bubble Condenser Experimental Qualification) Project in Brussels in December 1999 and on occasion of the 11. OECD Support Group Meeting in Berlin in April 2000. The discussions had evidenced several

  11. Polish polar research (outline

    Directory of Open Access Journals (Sweden)

    Krzysztof Ludwik Birkenmajer

    2017-12-01

    Full Text Available The article describes Polish research and discoveries in the Arctic and the Antarctic since the 19th century. The author is a geologist and since 1956 has been engaged in scientific field research on Spitsbergen, Greenland and Antarctica (23 expeditions. For many years chairman of the Committee on Polar Research of the Polish Academy of Sciences, he is now its Honorary Chairman.

  12. Laboratory Optimization Tests of Decontamination of Cs, Sr, and Actinides from Hanford Waste Treatment Plant Low Activity Waste Off-Gas Condensate Simulant

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Nash, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-01-06

    The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable less integrated operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also substantially decrease the LAW vitrification mission duration and quantity of glass waste.

  13. Waste Treatment And Immobilization Plant U. S. Department Of Energy Office Of River Protection Submerged Bed Scrubber Condensate Disposition Project - Abstract # 13460

    Energy Technology Data Exchange (ETDEWEB)

    Yanochko, Ronald M [Washington River Protection Solutions, Richland, WA (United States); Corcoran, Connie [AEM Consulting, LLC, Richland, WA (United States)

    2012-11-15

    The Hanford Waste Treatment and Immobilization Plant (WTP) will generate an off-gas treatment system secondary liquid waste stream [submerged bed scrubber (SBS) condensate], which is currently planned for recycle back to the WTP Low Activity Waste (LAW) melter. This SBS condensate waste stream is high in Tc-99, which is not efficiently captured in the vitrified glass matrix. A pre-conceptual engineering study was prepared in fiscal year 2012 to evaluate alternate flow paths for melter off-gas secondary liquid waste generated by the WTP LAW facility. This study evaluated alternatives for direct off-site disposal of this SBS without pre-treatment, which mitigates potential issues associated with recycling.

  14. Technological investigations and efficiency analysis of a steam heat exchange condenser: Conceptual design of a hybrid steam condenser

    OpenAIRE

    Kapooria, R K; Kumar, S; Kasana, K S

    2008-01-01

    Most of the electricity being produced throughout the world today is from steam power plants. At the same time, many other competent means of generating electricity have been developed viz. electricity from natural gas, MHD generators, biogas, solar cells, etc. But steam power plants will continue to be competent because of the use of water as the main working fluid which is abundantly available and is also reusable. The condenser remains among one of the key components of a steam power plant...

  15. Assessment of the environmental impact of available options in electric power development under Polish conditions

    International Nuclear Information System (INIS)

    Cofala, Janusz; ); Jankowski, Boleslaw

    1999-01-01

    The current European initiatives limiting environmental impacts of energy production and use are presented and the proposal emission levels together with benefits are given. The role of nuclear power in achieving environmental targets in the EU countries is stressed. Then a comparison of the following 3 major electricity production options: modern coal fired power plants, gas fired combined cycle power plants and nuclear power plants is done. In the comparison Polish conditions are taken into account

  16. Conformal polishing approach: Tool footprint analysis

    Directory of Open Access Journals (Sweden)

    José A Dieste

    2016-02-01

    Full Text Available Polishing process is one of the most critical manufacturing processes during a metal part production because it determines the final quality of the product. Free-form surface polishing is a handmade process with lots of rejected parts, scrap generation and time and energy consumption. Two different research lines are being developed: prediction models of the final surface quality parameters and an analysis of the amount of material removed depending on the polishing parameters to predict the tool footprint during the polishing task. This research lays the foundations for a future automatic conformal polishing system. It is based on rotational and translational tool with dry abrasive in the front mounted at the end of a robot. A tool to part concept is used, useful for large or heavy workpieces. Results are applied on different curved parts typically used in tooling industry, aeronautics or automotive. A mathematical model has been developed to predict the amount of material removed in function of polishing parameters. Model has been fitted for different abrasives and raw materials. Results have shown deviations under 20% that implies a reliable and controllable process. Smaller amount of material can be removed in controlled areas of a three-dimensional workpiece.

  17. Improved crud iron removal efficiency for powder resin type condensate filters

    International Nuclear Information System (INIS)

    Nagai, Hiroshi; Ino, Takao

    1989-01-01

    In 1984, a precoat type condensate filtration system was delivered to The Tokyo Electric Power Co., Inc. by Ebara and stable operation of the system is reported ever since. Originally, condensate filtration systems are used to remove crud iron in condensate water. However, it has become desirable to freely control the crud iron in the outlet flow of such filtration system. The main source of radioactivity in a BWR plant, is Cobalt 60, and it is necessary to optimally control the amount of crud iron released into the reactor to match the nickel and cobalt amounts in the reactor feed water for achieving an overall reduction of the concentration of radioactivity within the BWR plant. The method of such control, developed by the authors, is outlined in the following. By this method, the radioactive level within the overall plant is significantly decreased. Consequently, the risk of radioactive exposure of personnel at time of periodical checkup is greatly reduced. (author)

  18. Test facility of the VVER-440 condensation-type pressure suppression system

    International Nuclear Information System (INIS)

    Wolff, H.; Arndt, S.

    2004-01-01

    Since the early nineties, GRS has supported regulatory authorities in Central and Eastern Europe in performing safety assessments of nuclear power plants. Especially studies of the condensation-type pressure suppression system of VVER-440/V-213-type plants have been important in this respect. Major steps in demonstrating complete functioning of the condensation-type pressure suppression system under accident conditions by experiments run in the Russian large scale test facility, BC V-213, have been completed in the past two years within the framework of various international experimental programs. The test results were used to validate specifically for power plants with VVER-400/V-213 reactors the COCOSYS GRS computer code, which is used in the safety assessments. The results of recalculations of the C02 EREC test, which simulates a break of a main steam pipe, demonstrate the present state of validation of COCOSYS for VVER condensation-type pressure suppression systems. (orig.) [de

  19. Improvement of reliability of heater and condenser

    International Nuclear Information System (INIS)

    Yamagishi, Hiroki

    1988-01-01

    Recently, the diversification of the operation modes of power plants has advanced as well as daily start and stop and weekly start and stop operations, as the result, the needs for the reliability improvement of various heat exchangers around steam turbines heighten. In newly constructed plants, the design to meet this demand is carried out, but also in existing platns, the application of the latest technology is investigated. As for the reliability of condensers, aluminum brass cooling tubes have been used by doing the optimal maintenance and taking the measures against deposit attack. In the case of requiring high reliability, the examples of adopting titanium cooling tubes increased. The technology of titanium tube condensers, completely assembled condensers, the replacement of existing brass tubes with titanium tubes and so on are discussed. In the case of feed heaters, the deterioration phenomena due to the lapse of long years, such as the attack of steel tube inlet, the drain attack on the external surfaces of steel tubes, the ammonia attack of aluminum brass tubes and the adhesion of scale to heaters, are explained, and the countermeasures are shown. (Kako, I.)

  20. Zerodur polishing process for high surface quality and high efficiency

    International Nuclear Information System (INIS)

    Tesar, A.; Fuchs, B.

    1992-08-01

    Zerodur is a glass-ceramic composite importance in applications where temperature instabilities influence optical and mechanical performance, such as in earthbound and spaceborne telescope mirror substrates. Polished Zerodur surfaces of high quality have been required for laser gyro mirrors. Polished surface quality of substrates affects performance of high reflection coatings. Thus, the interest in improving Zerodur polished surface quality has become more general. Beyond eliminating subsurface damage, high quality surfaces are produced by reducing the amount of hydrated material redeposited on the surface during polishing. With the proper control of polishing parameters, such surfaces exhibit roughnesses of < l Angstrom rms. Zerodur polishing was studied to recommend a high surface quality polishing process which could be easily adapted to standard planetary continuous polishing machines and spindles. This summary contains information on a polishing process developed at LLNL which reproducibly provides high quality polished Zerodur surfaces at very high polishing efficiencies

  1. Strategies for sustainable development of the Polish electric power system

    International Nuclear Information System (INIS)

    Janiczek, R.

    1996-01-01

    The key features of sustainable development of the Polish electric power industry are discussed. Priorities and limitations for changes and power demand forecasts are described. Results of least-cost planning for existing power plants' modernization and generation expansion with environmental impacts are presented. The least-cost strategy is given by the optimal upgrades of older plants until year 2002 and by expansion of gas-fired units. The limited availability of gas after 2010 will lead to the construction of new coal-fired plants. For the next planning process, an integrated resource planning methodology is proposed, which includes dynamic optimization of supply and demand side options. Innovative mechanisms are shown to overcome barriers of development like long-terms contracts and decentralization of the power system planning process. (author)

  2. Assessment of the anthelmintic activity of medicinal plant extracts and purified condensed tannins against free-living and parasitic stages of Oesophagostomum dentatum

    DEFF Research Database (Denmark)

    Williams, Andrew Richard; Ropiak, Honorata M.; Fryganas, Christos

    2014-01-01

    BackgroundPlant-derived condensed tannins (CT) show promise as a complementary option to treat gastrointestinal helminth infections, thus reducing reliance on synthetic anthelmintic drugs. Most studies on the anthelmintic effects of CT have been conducted on parasites of ruminant livestock. Oesop...

  3. Studies on the causes of failures in titanium tube condensers of nuclear power plants

    International Nuclear Information System (INIS)

    Kim, Uh Chul; Kim, Joung Soo; Jang, Soon Sik; Park, Su Hoon; Chung, Han Sub; Hwang, Seong Sik

    1990-03-01

    All condenser tubes in domestic nuclear power plants using sea water as condenser coolant are Ti material, while water boxes and tubesheets are, respectively, made of carbon steel and Cu-alloys. In this case, to prevent galvanic corrosion occuring between these materials, cathodic protection by an impressed direct current method is being used. Under inappropriate conditions, however, over-protection can generate hydrogen gas on Ti-tube surfaces, which may cause hydrogen embrittlement to the Ti tubes. Therefore, proper conditions for appropriate cathodic protection must be obtained through experiments. Galvanic corrosion between these three different materials was investigated, first. When SA 285 is coupled with Cu or Ti in sea water, under the same surface area, galvanic corrosion rate of SA 285 significantly increases (For example, corrosion rate increment, 2 x 10 -1 → 8 ma for SA 285 coupled with Cu). It was also affected by Cu more than by Ti. In addition, as the surface area ratio of SA 285 to Ti decreases, the corrosion rate of SA 285 increases. This is similar to SA 285-Cu couple. In this case, corrosion rate of SA 285 is higher than that of SA 285-Ti system. For Cu-Ti coulpe, as the surface area ratio of Cu to Ti increases, current density increases slightly up to 1.5 μA/cm 2 , which is very low. (author)

  4. Radwaste reduction through use of condensate non-precoat filters at Perry Nuclear Power Plant

    International Nuclear Information System (INIS)

    Hartman, J.L.

    1996-01-01

    The concept of non-precoat filtration to remove iron oxide without generating traditional resin and fiber precoat material, which is expensive to dispose of as radwaste, is rapidly becoming a trend of the 90's. In 1991, in response to escalating radwaste disposal costs, Perry Nuclear Power Plant was the first BWR to install non-precoat filters (septa) on a full scale basis in a Condensate System. To date, non-precoat septa from three vendors; including Memtec Power Generation have been installed and operated at Perry. It is important that other utilities considering this technology be given as much open-quotes real lifeclose quotes operational data as possible. This paper presents the data from three different companies and provides recommendations for consideration

  5. Chemical polishing of partially oxidized T-111 alloy

    International Nuclear Information System (INIS)

    Teaney, P.E.

    1974-01-01

    The specimens were pressure-mounted in Bakelite and ground through 600 grit on silicon carbide papers. The specimens were rough-polished on a vibratory polisher for 4 to 6 h, using a water slurry of one micron alumina on Texmet, followed by 0.3-μ alumina on Texmet overnight. Final polishing was accomplished by continuous swabbing with a chemical polish. A chemical polish consisting of ten parts lactic acid, four parts nitric acid, and four parts hydrofluoric acid worked well for the T-111 parent material specimens; however, in the partially oxidized specimens, considerable pitting and staining occurred in the oxygen-affected zone and in the transition zone between the oxygen-affected zone and the parent material. A chemical polish was developed for the partially oxidized specimens by adjusting the ratio of the acids to ten parts lactic acid, two parts nitric acid, and two parts hydrofluoric acid. This slowed the chemical attack on the oxygen-affected zone considerably and, with continuous swabbing, the pitting and stain could be avoided. The specimens were rinsed and checked occasionally on the metallograph to determine when the proper polish had been obtained. Some specimens required intermittent polishing times up to 1 / 2 hour. No relationship could be established between the oxygen content of the specimen and the time required for chemical polishing in the partially oxidized specimens. However, the microstructure of the transition zone was the most difficult to obtain, and specimens with uniform reaction zones across the width of the specimen polished quicker than those with the transition zone

  6. Extraction and quantification of "condensed tannins" as a measure of plant anti-herbivore defence? Revisiting an old problem.

    Science.gov (United States)

    Heil, Martin; Baumann, Birgit; Andary, Claude; Linsenmair, K Eduard; McKey, Doyle

    2002-11-01

    Contents of phenolic compounds in leaf extracts often serve as a measure of plant anti-herbivore defence. This method suffers from the multifunctionality of phenolics and from problems with their colorimetric quantification. Here we present further evidence for the pertinence of these problems. Contents of condensed tannins (CCT) were spectrophotometrically quantified in leaf extracts of 11 closely related mimosoid species, and Spodoptera littoralis caterpillars were reared on artificial diet containing these extracts. The relationship of CCT with caterpillar growth differed considerably among plant species, since both positive and negative correlations were detected. There was, however, a negative correlation of CCT with fungal spore germination, indicating a role of these compounds in resistance to fungi. Detailed knowledge on the structure and biological function of defensive compounds and on the overall composition of leaves is required to estimate a plant's defensive efficacy against a particular group of enemies.

  7. Graphite Composite Panel Polishing Fixture

    Science.gov (United States)

    Hagopian, John; Strojny, Carl; Budinoff, Jason

    2011-01-01

    The use of high-strength, lightweight composites for the fixture is the novel feature of this innovation. The main advantage is the light weight and high stiffness-to-mass ratio relative to aluminum. Meter-class optics require support during the grinding/polishing process with large tools. The use of aluminum as a polishing fixture is standard, with pitch providing a compliant layer to allow support without deformation. Unfortunately, with meter-scale optics, a meter-scale fixture weighs over 120 lb (.55 kg) and may distort the optics being fabricated by loading the mirror and/or tool used in fabrication. The use of composite structures that are lightweight yet stiff allows standard techniques to be used while providing for a decrease in fixture weight by almost 70 percent. Mounts classically used to support large mirrors during fabrication are especially heavy and difficult to handle. The mount must be especially stiff to avoid deformation during the optical fabrication process, where a very large and heavy lap often can distort the mount and optic being fabricated. If the optic is placed on top of the lapping tool, the weight of the optic and the fixture can distort the lap. Fixtures to support the mirror during fabrication are often very large plates of aluminum, often 2 in. (.5 cm) or more in thickness and weight upwards of 150 lb (68 kg). With the addition of a backing material such as pitch and the mirror itself, the assembly can often weigh over 250 lb (.113 kg) for a meter-class optic. This innovation is the use of a lightweight graphite panel with an aluminum honeycomb core for use as the polishing fixture. These materials have been used in the aerospace industry as structural members due to their light weight and high stiffness. The grinding polishing fixture consists of the graphite composite panel, fittings, and fixtures to allow interface to the polishing machine, and introduction of pitch buttons to support the optic under fabrication. In its

  8. Adsorption treatment of oxide chemical mechanical polishing wastewater from a semiconductor manufacturing plant by electrocoagulation

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Wei-Lung, E-mail: wlchou@sunrise.hk.edu.tw [Department of Safety, Health and Environmental Engineering, Hungkuang University, No. 34, Chung-Chie Road, Sha-Lu, Taichung 433, Taiwan (China); Wang, Chih-Ta [Department of Safety Health and Environmental Engineering, Chung Hwa University of Medical Technology, Tainan Hsien 717, Taiwan (China); Chang, Wen-Chun; Chang, Shih-Yu [Department of Safety, Health and Environmental Engineering, Hungkuang University, No. 34, Chung-Chie Road, Sha-Lu, Taichung 433, Taiwan (China)

    2010-08-15

    In this study, metal hydroxides generated during electrocoagulation (EC) were used to remove the chemical oxygen demand (COD) of oxide chemical mechanical polishing (oxide-CMP) wastewater from a semiconductor manufacturing plant by EC. Adsorption studies were conducted in a batch system for various current densities and temperatures. The COD concentration in the oxide-CMP wastewater was effectively removed and decreased by more than 90%, resulting in a final wastewater COD concentration that was below the Taiwan discharge standard (100 mg L{sup -1}). Since the processed wastewater quality exceeded the direct discharge standard, the effluent could be considered for reuse. The adsorption kinetic studies showed that the EC process was best described using the pseudo-second-order kinetic model at the various current densities and temperatures. The experimental data were also tested against different adsorption isotherm models to describe the EC process. The Freundlich adsorption isotherm model predictions matched satisfactorily with the experimental observations. Thermodynamic parameters, including the Gibbs free energy, enthalpy, and entropy, indicated that the COD adsorption of oxide-CMP wastewater on metal hydroxides was feasible, spontaneous and endothermic in the temperature range of 288-318 K.

  9. Adsorption treatment of oxide chemical mechanical polishing wastewater from a semiconductor manufacturing plant by electrocoagulation

    International Nuclear Information System (INIS)

    Chou, Wei-Lung; Wang, Chih-Ta; Chang, Wen-Chun; Chang, Shih-Yu

    2010-01-01

    In this study, metal hydroxides generated during electrocoagulation (EC) were used to remove the chemical oxygen demand (COD) of oxide chemical mechanical polishing (oxide-CMP) wastewater from a semiconductor manufacturing plant by EC. Adsorption studies were conducted in a batch system for various current densities and temperatures. The COD concentration in the oxide-CMP wastewater was effectively removed and decreased by more than 90%, resulting in a final wastewater COD concentration that was below the Taiwan discharge standard (100 mg L -1 ). Since the processed wastewater quality exceeded the direct discharge standard, the effluent could be considered for reuse. The adsorption kinetic studies showed that the EC process was best described using the pseudo-second-order kinetic model at the various current densities and temperatures. The experimental data were also tested against different adsorption isotherm models to describe the EC process. The Freundlich adsorption isotherm model predictions matched satisfactorily with the experimental observations. Thermodynamic parameters, including the Gibbs free energy, enthalpy, and entropy, indicated that the COD adsorption of oxide-CMP wastewater on metal hydroxides was feasible, spontaneous and endothermic in the temperature range of 288-318 K.

  10. Adsorption treatment of oxide chemical mechanical polishing wastewater from a semiconductor manufacturing plant by electrocoagulation.

    Science.gov (United States)

    Chou, Wei-Lung; Wang, Chih-Ta; Chang, Wen-Chun; Chang, Shih-Yu

    2010-08-15

    In this study, metal hydroxides generated during electrocoagulation (EC) were used to remove the chemical oxygen demand (COD) of oxide chemical mechanical polishing (oxide-CMP) wastewater from a semiconductor manufacturing plant by EC. Adsorption studies were conducted in a batch system for various current densities and temperatures. The COD concentration in the oxide-CMP wastewater was effectively removed and decreased by more than 90%, resulting in a final wastewater COD concentration that was below the Taiwan discharge standard (100 mg L(-1)). Since the processed wastewater quality exceeded the direct discharge standard, the effluent could be considered for reuse. The adsorption kinetic studies showed that the EC process was best described using the pseudo-second-order kinetic model at the various current densities and temperatures. The experimental data were also tested against different adsorption isotherm models to describe the EC process. The Freundlich adsorption isotherm model predictions matched satisfactorily with the experimental observations. Thermodynamic parameters, including the Gibbs free energy, enthalpy, and entropy, indicated that the COD adsorption of oxide-CMP wastewater on metal hydroxides was feasible, spontaneous and endothermic in the temperature range of 288-318 K. Copyright 2010 Elsevier B.V. All rights reserved.

  11. Dropwise condensation on hydrophobic bumps and dimples

    Science.gov (United States)

    Yao, Yuehan; Aizenberg, Joanna; Park, Kyoo-Chul

    2018-04-01

    Surface topography plays an important role in promoting or suppressing localized condensation. In this work, we study the growth of water droplets on hydrophobic convex surface textures such as bumps and concave surface textures such as dimples with a millimeter scale radius of curvature. We analyze the spatio-temporal droplet size distribution under a supersaturation condition created by keeping the uniform surface temperature below the dew point and show its relationship with the sign and magnitude of the surface curvature. In particular, in contrast to the well-known capillary condensation effect, we report an unexpectedly less favorable condensation on smaller, millimeter-scale dimples where the capillary condensation effect is negligible. To explain these experimental results, we numerically calculated the diffusion flux of water vapor around the surface textures, showing that its magnitude is higher on bumps and lower on dimples compared to a flat surface. We envision that our understanding of millimetric surface topography can be applied to improve the energy efficiency of condensation in applications such as water harvesting, heating, ventilation, and air conditioning systems for buildings and transportation, heat exchangers, thermal desalination plants, and fuel processing systems.

  12. APS 3D: a new benchmark in aspherical polishing

    Science.gov (United States)

    Gauch, Daniel; Mikulic, Dalibor; Veit, Christian

    2017-10-01

    The APS 3D system performs polishing and form correction in one step in order to reduce overall process time, reduce the number of polishing steps required and eliminate the need for highly skilled operators while providing a repeatable polishing process. This new 3D Polishing system yields better surface quality, and a better slope error, automatically determining the optimum speeds, feed rates and polish pressures to achieve a deterministic process based on the required quality parameters input by the operator. The process flow is always the same to ensure consistent quality and target quality values are defined before polishing begins.

  13. Allocation of synchronous condensers for restoration of system short-circuit power

    DEFF Research Database (Denmark)

    Marrazi, Emanuel; Yang, Guangya; Weinreich-Jensen, Peter

    2017-01-01

    Modern power systems, employing an increasing number of converter-based renewable energy sources (RES) and decreasing the usage of conventional power plants, are leading to lower levels of short-circuit power and rotational inertia. A solution to this is the employment of synchronous condensers...... in the grid, in order to provide sufficient short-circuit power. This results in the increase of the short-circuit ratio (SCR) at transmission system bus-bars serving as points of interconnection (POI) to renewable generation. Evaluation of the required capacity and grid-location of the synchronous condensers...... by renewable generation. Total cost of synchronous condenser installations in the system is minimized and the SCRs at the POIs of central renewable power plants are strengthened. The method has potential for application on larger grids, aiding grid-integration of RES....

  14. Ice condenser containment analysis with the GOTHIC code

    International Nuclear Information System (INIS)

    Yadon, T.P.

    1996-01-01

    Analytical methodologies have recently been developed by Duke Power Company (Duke) to calculate the thermodynamic response of the ice condenser containment buildings at the McGuire and Catawba Nuclear Stations to high-energy line breaks. The GOTHIC computer code (Version 4.0) was utilized for these analyses. In the ice condenser containment design, a large mass of ice stored within the containment building is used to absorb the energy released from high-energy line breaks, thereby limiting the peak pressure and temperature in the containment building to within design limits. The McGuire and Catawba Nuclear Stations (both two-unit, 3411 MWth four-loop Westinghouse plants) are of the ice condenser containment design

  15. Titanium condenser tubes. Problems and their solution for wider application to large surface condensers. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Sato, S; Sugiyama, S; Nagata, K; Nanba, K; Shimono, M [Sumitomo Light Metal Industries Ltd., Tokyo (Japan)

    1977-06-01

    The corrosion resistance of titanium in sea water is extremely excellent, but titanium tubes are expensive, and the copper alloy tubes resistant in polluted sea water were developed, therefore they were not used practically. In 1970, ammonia attack was found on the copper alloy tubes in the air-cooled portion of condensers, and titanium tubes have been used as the countermeasure. As the result of the use, the galvanic attack on copper alloy tube plates with titanium tubes as cathode and the hydrogen absorption at titanium tube ends owing to excess electrolytic protection was observed, but the corrosion resistance of titanium tubes was perfect. These problems can be controlled by the application of proper electrolytic protection. The condensers with all titanium tubes adopted recently in USA are intended to realize perfectly no-leak condensers as the countermeasure to the corrosion in steam generators of PWR plants. Regarding large condensers of nowadays, three problems are pointed out, namely the vibration of condenser tubes, the method of joining tubes and tube plates, and the tubes of no coolant leak. These three problems in case of titanium tubes were studied, and the problem of the fouling of tubes was also examined. The intervals of supporting plates for titanium tubes should be narrowed. The joining of titanium tubes and titanium tube plates by welding is feasible and promising. The cleaning with sponge balls is effective to control fouling.

  16. Polish Americans. Second, Revised Edition.

    Science.gov (United States)

    Lopata, Helen Znaniecka

    This book examines Polonia, the Polish ethnic community in America created by three giant waves of immigration between 1880 and 1990. The complicated history of this ethnic group is reflected in the lives of increasing numbers of Polish Americans, including recent immigrants brought by political and economic changes, as they achieve middle class…

  17. Experimental Polish-Lithuanian Corpus with the Semantic Annotation Elements

    Directory of Open Access Journals (Sweden)

    Danuta Roszko

    2015-06-01

    Full Text Available Experimental Polish-Lithuanian Corpus with the Semantic Annotation Elements In the article the authors present the experimental Polish-Lithuanian corpus (ECorpPL-LT formed for the idea of Polish-Lithuanian theoretical contrastive studies, a Polish-Lithuanian electronic dictionary, and as help for a sworn translator. The semantic annotation being brought into ECorpPL-LT is extremely useful in Polish-Lithuanian contrastive studies, and also proves helpful in translation work.

  18. Waste Treatment And Immobilization Plant U. S. Department Of Energy Office Of River Protection Submerged Bed Scrubber Condensate Disposition Project - Abstract no. 13460

    International Nuclear Information System (INIS)

    Yanochko, Ronald M; Corcoran, Connie

    2012-01-01

    The Hanford Waste Treatment and Immobilization Plant (WTP) will generate an off-gas treatment system secondary liquid waste stream [submerged bed scrubber (SBS) condensate], which is currently planned for recycle back to the WTP Low Activity Waste (LAW) melter. This SBS condensate waste stream is high in Tc-99, which is not efficiently captured in the vitrified glass matrix. A pre-conceptual engineering study was prepared in fiscal year 2012 to evaluate alternate flow paths for melter off-gas secondary liquid waste generated by the WTP LAW facility. This study evaluated alternatives for direct off-site disposal of this SBS without pre-treatment, which mitigates potential issues associated with recycling

  19. Effects of the selection of heat transfer fluid and condenser type on the performance of a solar thermal power plant with technoeconomic approach

    International Nuclear Information System (INIS)

    Yilmazoglu, M. Zeki

    2016-01-01

    Highlights: • The effects of the selection of HTF and condenser type on STPs were examined. • Levelized cost of energy (LCOE) for STP was investigated. • LCOE for STP compared with gas turbine and combined cycle. • CSP with thermal storage can be competitive technology with carbon tax/credits. - Abstract: Renewable electricity generation systems have an increasing trend in terms of usage due to aiming to decrease greenhouse gas emissions and energy source diversification strategies of countries. Parabolic trough, Fresnel, and solar tower systems have been used to generate solar thermal electricity around the world. In this study, the effects of the selection of collector heat transfer fluid (HTF) and condenser type on a concentrated solar thermal power plant were analyzed. Net power, net electrical efficiency, and economic analysis were carried out for the selected HTFs for different collector outlet temperature cases. In the case of condenser type selection four different systems were considered; water cooled, air cooled (dry air) and air cooled with water spraying (spraying before fan and spraying before and after fan). Levelized cost of energy (LCOE) and specific investment cost were calculated. According to the results, specific investment cost and LCOE were found to be 4000 USD/kW_e_l and 0.207 USD/kW h, respectively. Carbon tax/credit was also included to the calculations of LCOE and a comparison study was carried out for gas turbine, combined cycle and solar thermal power plant with thermal storage. Including carbon tax/credit to the LCOE shows that solar thermal power plant with heat storage can be competitive when compared to gas turbines.

  20. Numerical Study of Condensation Heat Exchanger Design in a Cooling jacket: Correlation Investigation

    International Nuclear Information System (INIS)

    Kim, Myoung Jun; Lee, Hee Joon; Kang, Han Ok; Lee, Tae Ho; Park, Cheon Tae

    2013-01-01

    In this study, condensing heat transfer correlation of TSCON is evaluated with the existing experimental data set to design condensation heat exchanger without noncondensable gas effect (pure steam condensation) in a cooling jacket. From the investigation of the existing condensation heat transfer correlation to the existing experimental data, the improved Shah's correlation showed most satisfactory result for the condensation heat transfer coefficient with experimental data of Khun in a cooling jacket, whereas the Shah's correlation with experimental data of Lee. Lee et al. reported the improved Shah correlation gave us the best predictor for the condensation heat transfer data of Kim and Henderson in a subcooled and saturated water pool. They suggested the improved Shah correlation should be adopted as condensation heat transfer module in TSCON(Thermal Sizing of CONdenser) to design condensation heat exchanger in secondary passive cooling system of nuclear plant

  1. Laser polishing of additive manufactured Ti alloys

    Science.gov (United States)

    Ma, C. P.; Guan, Y. C.; Zhou, W.

    2017-06-01

    Laser-based additive manufacturing has attracted much attention as a promising 3D printing method for metallic components in recent years. However, surface roughness of additive manufactured components has been considered as a challenge to achieve high performance. In this work, we demonstrate the capability of fiber laser in polishing rough surface of additive manufactured Ti-based alloys as Ti-6Al-4V and TC11. Both as-received surface and laser-polished surfaces as well as cross-section subsurfaces were analyzed carefully by White-Light Interference, Confocal Microscope, Focus Ion Beam, Scanning Electron Microscopy, Energy Dispersive Spectrometer, and X-ray Diffraction. Results revealed that as-received Ti-based alloys with surface roughness more than 5 μm could be reduce to less than 1 μm through laser polishing process. Moreover, microstructure, microhardness and wear resistance of laser-polished zone was investigated in order to examine the thermal effect of laser polishing processing on the substrate of additive manufactured Ti alloys. This proof-of-concept process has the potential to effectively improve the surface roughness of additive manufactured metallic alloy by local polishing method without damage to the substrate.

  2. Environmental sustainability by adoption of alternate cooling media for condenser cooling

    International Nuclear Information System (INIS)

    Gandhi, Jaymin; Patel, Nilesh

    2015-01-01

    Water having ability to dissolve most substances and to support biological life, every cooling water system in power plant is subjected to potential operational problems which are mainly corrosion, scaling and biological fouling. Control of cooling water chemistry is very critical in preventing above said problems. In view of scarcity of water and looking into the future trends in the environment protection, water media can be replaced with air. Having such concept in thermal and combined cycle power plants, use of Air-cooled condenser (ACC) for Nuclear power plant may be explored. During last decade number of installations with ACC also increased, largely in response to the growing attention being paid to environmental concerns as well of water scarcity. The rising importance of 'Save Water and Environment', calls for a broader understanding of the design and application principles involved for ACC. This paper identifies the basic configurations of air cooled condensers used in the power industry together with their merits and demerits when compared to those exhibited by traditional steam surface condensers including environmental and corrosion issues. Several factors that affect the performance of air-cooled condensers are described in detail, especially the consequences that result from the fouling of the finned-tubes. To rectify the degradations in performance that result from external tube fouling, a number of cleaning procedures are described. Due to relatively high cost of sweet water and large requirement of sea water, Air cooled condenser may become viable option in future. (author)

  3. Condensed listing of surface boreholes at the Waste Isolation Pilot Plant Project through 31 December 1995

    International Nuclear Information System (INIS)

    Hill, L.R.; Aguilar, R.; Mercer, J.W.; Newman, G.

    1997-01-01

    This report contains a condensed listing of Waste Isolation Pilot Plant (WIPP) project surface boreholes drilled for the purpose of site selection and characterization through 31 December 1995. The US Department of Energy (DOE) sponsored the drilling activities, which were conducted primarily by Sandia National Laboratories. The listing provides physical attributes such as location (township, range, section, and state-plane coordinates), elevation, and total borehole depth, as well as the purpose for the borehole, drilling dates, and information about extracted cores. The report also presents the hole status (plugged, testing, monitoring, etc.) and includes salient findings and references. Maps with borehole locations and times-of-drilling charts are included

  4. Numerical Study of Condensation Heat Exchanger Design in a Cooling jacket: Correlation Investigation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myoung Jun; Lee, Hee Joon [Kookmin Univ., Seoul (Korea, Republic of); Kang, Han Ok; Lee, Tae Ho; Park, Cheon Tae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    In this study, condensing heat transfer correlation of TSCON is evaluated with the existing experimental data set to design condensation heat exchanger without noncondensable gas effect (pure steam condensation) in a cooling jacket. From the investigation of the existing condensation heat transfer correlation to the existing experimental data, the improved Shah's correlation showed most satisfactory result for the condensation heat transfer coefficient with experimental data of Khun in a cooling jacket, whereas the Shah's correlation with experimental data of Lee. Lee et al. reported the improved Shah correlation gave us the best predictor for the condensation heat transfer data of Kim and Henderson in a subcooled and saturated water pool. They suggested the improved Shah correlation should be adopted as condensation heat transfer module in TSCON(Thermal Sizing of CONdenser) to design condensation heat exchanger in secondary passive cooling system of nuclear plant.

  5. Condensation nuclear power plants with water-cooled graphite-moderated channel type reactors and advances in their development

    International Nuclear Information System (INIS)

    Boldyrev, V.M.; Mikhaj, V.I.

    1985-01-01

    Consideration is being given to results of technical and economical investigations of advisability of increasing unit power by elevating steam generating capacity as a result of inserting numerous of stereotype sectional structural elements of the reactor with similar thermodynamic parameters. It is concluded that construction of power units of condensation nuclear power plants with water-cooled graphite-moderated channel type reactors of 2400-3200 MWe and higher unit power capacity represents the real method for sharp growth of efficiency and labour productivity in power industry. It can also provide the required increase of the rate of putting electrogenerating powers into operation

  6. Polishing ponds as tertiary treatment of municipal wastewater. Part one: Full scale experimental evaluation of effects on effluent characteristic; Stagni biologici nel trattamento terziario dei liquami urbani. Parte I: Valutazione sperimentale a scala reale degli effetti sulle caratteristiche all`effluente finale

    Energy Technology Data Exchange (ETDEWEB)

    Tatano, Fabio

    1997-04-01

    The application of polishing ponds as tertiary treatment of municipal wastewater, is quite common in Germany. Nowadays, the wastewater treatment plants in the most industrialized Countries achieve high treatment efficiencies in the biological phase; then, it seems necessary to study - in these plants - the treatment efficiencies and the improvements achievable with polishing ponds inserted as tertiary treatment. This Part One of the paper describes the results of a full scale experimental evaluation of the treatment efficiency of the polishing ponds in a wastewater treatment plant situated in the Ruhr River Region (Germany).

  7. Polishing of silicon based advanced ceramics

    Science.gov (United States)

    Klocke, Fritz; Dambon, Olaf; Zunke, Richard; Waechter, D.

    2009-05-01

    Silicon based advanced ceramics show advantages in comparison to other materials due to their extreme hardness, wear and creep resistance, low density and low coefficient of thermal expansion. As a matter of course, machining requires high efforts. In order to reach demanded low roughness for optical or tribological applications a defect free surface is indispensable. In this paper, polishing of silicon nitride and silicon carbide is investigated. The objective is to elaborate scientific understanding of the process interactions. Based on this knowledge, the optimization of removal rate, surface quality and form accuracy can be realized. For this purpose, fundamental investigations of polishing silicon based ceramics are undertaken and evaluated. Former scientific publications discuss removal mechanisms and wear behavior, but the scientific insight is mainly based on investigations in grinding and lapping. The removal mechanisms in polishing are not fully understood due to complexity of interactions. The role of, e.g., process parameters, slurry and abrasives, and their influence on the output parameters is still uncertain. Extensive technological investigations demonstrate the influence of the polishing system and the machining parameters on the stability and the reproducibility. It is shown that the interactions between the advanced ceramics and the polishing systems is of great relevance. Depending on the kind of slurry and polishing agent the material removal mechanisms differ. The observed effects can be explained by dominating mechanical or chemo-mechanical removal mechanisms. Therefore, hypotheses to state adequate explanations are presented and validated by advanced metrology devices, such as SEM, AFM and TEM.

  8. Thermodynamic effects when utilizing waste heat from condensation in cases of a reduced vacuum in steam turbine plants of thermal power stations, to provide heat at low temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Vasiljevic, N.; Savic, B.; Stojakovic, M.

    1986-01-01

    There is an interesting variant of cogeneration in the steam turbine system of a thermal power plant, i.e. the utilisation of the waste heat of condensation with a reduced vacuum without reconstruction of the thermal power plant. The thermodynamic effect in cogeneration was calculated in consideration of the dynamics of heat consumption. This cogeneration process has the advantage of saving primary energy without reconstruction of the thermal power plant.

  9. Experimental and theoretical investigations on condensation heat transfer at very low pressure to improve power plant efficiency

    International Nuclear Information System (INIS)

    Berrichon, J.D.; Louahlia-Gualous, H.; Bandelier, Ph.; Bariteau, N.

    2014-01-01

    Highlights: • Theoretical model for condensation heat transfer at very low pressure is developed using only one iterative loop. • Experimental results on steam and air steam condensation heat transfer at very low pressure are presented. • The developed model gives the good predictions for local condensation heat transfer at low pressure. • A maximal deterioration of 50% in condensation heat transfer is obtained at low pressure for air fraction of 4%. • A new correlation including effect of a wavy film surface for steam condensation at low pressure is suggested. - Abstract: This paper presents experimental investigation on the influence of very low pressure on local and average condensation heat transfer in a vertical tube. Furthermore, this paper develops an analytical study for film condensation heat transfer coefficient in the presence of non-condensable gas inside a vertical tube. The condensate film thickness is calculated for each location in a tube using mass and heat transfer analogy. The effects of interfacial shear stress and waves on condensate film surface are included in the model. The comparative studies show that the present model well predicts the experimental data of Khun et al. [1]for local condensation of steam air mixture at high pressure. Different correlations defined for condensation heat transfer are evaluated. It is found that the correlations of Cavallini and Zecchin [2] and Shah [3] are the closest to the calculated steam condensation local heat transfer coefficient. The model gives a satisfactory accuracy with the experimental results for condensation heat transfer at very low pressure. The mean deviation between the predictions of the theoretical model with the measurements for pure saturated vapor is 12%. Experimental data show that the increase of air fraction to 4% deteriorates condensation heat transfer at low pressure up to 50%

  10. Water feeding/condensating device and operation method in nuclear power plant

    International Nuclear Information System (INIS)

    Shibayama, Takashi.

    1989-01-01

    The present invention overcomes a problem in reactor water level control occurring upon operation of a water feeding/condensating system in a nuclear power plant. That is, the water feed system to a nuclear reactor is constituted with parallel circuit comprising a reactor feedwater pump driven by a steam turbine and a serial circuit composed of a reactor feedwater pump driven by an electrical motor and a pump adjusting valve for controlling the amount of feedwater at the exit of the motor driven feedwater pump. Further, a reactor feedwater control valve having a function of controlling the feedwater to the reactor is disposed to the bypass pipeway for bypassing the parallel circuit of feedwater pumps. In this constitution, water can be fed to the nuclear reactor by way of the reactor feedwater pump bypass control valve upon starting and stopping of a nuclear feedwater pump driven by electric motor upon starting and shutdown of the nuclear reactor. Accordingly, stable water level control can be conducted for the reactor core with no effect of rapid pressure fluctuation due to the starting and the stopping of the reactor feedwater pump driven by electric motor. (I.S.)

  11. Study on chemical mechanical polishing of silicon wafer with megasonic vibration assisted.

    Science.gov (United States)

    Zhai, Ke; He, Qing; Li, Liang; Ren, Yi

    2017-09-01

    Chemical mechanical polishing (CMP) is the primary method to realize the global planarization of silicon wafer. In order to improve this process, a novel method which combined megasonic vibration to assist chemical mechanical polishing (MA-CMP) is developed in this paper. A matching layer structure of polishing head was calculated and designed. Silicon wafers are polished by megasonic assisted chemical mechanical polishing and traditional chemical mechanical polishing respectively, both coarse polishing and precision polishing experiments were carried out. With the use of megasonic vibration, the surface roughness values Ra reduced from 22.260nm to 17.835nm in coarse polishing, and the material removal rate increased by approximately 15-25% for megasonic assisted chemical mechanical polishing relative to traditional chemical mechanical polishing. Average Surface roughness values Ra reduced from 0.509nm to 0.387nm in precision polishing. The results show that megasonic assisted chemical mechanical polishing is a feasible method to improve polishing efficiency and surface quality. The material removal and finishing mechanisms of megasonic vibration assisted polishing are investigated too. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. STUDY OF POLISHING AISI 316L WITH STRUCTURED ABRASIVE

    Directory of Open Access Journals (Sweden)

    François GOOSSENS

    2015-05-01

    Full Text Available Finishing process like polishing is usually used to obtain high quality mechanical surface characteristics such as texture and roughness. These operations are mainly handmade and need highly trained operators thus limiting their repeatability and profitability. To optimize the industrialization of the polishing process, it is therefore necessary to modelize the process to built efficient parameter database. The aim of this study is to characterise the polishing of 316L stainless steel with structured abrasive belts. The geometric data of the belts are given, and we then propose a model to determine material removal. An experimental test bench is set up to test this model and characterise the polishing process in terms of forces. It produces samples for different polishing conditions. The different polished surfaces are then analyzed thanks to the roughness and the wettability. Using experimental designs, we are able to validate the proposed model and identify the parameters that influence a polishing operation.

  13. Development of computer program for the economic evaluation of the volume reduction system for the low-level radioactive waste

    International Nuclear Information System (INIS)

    Yang, Jin Yeong; Lee, Kun Jai

    1994-01-01

    This study provides the basis for investigating the benefits of purchasing volume reduction equipment and includes the establishment of a volume reduction data base, the creation of the volume reduction cost analysis computer program PEEVR (Program of Economic Evaluation for the Volume Reduction), and a generic analysis designed to identify the major costs influencing the economics of the various equipment options. In treating the plant types and the wastes, this study considers that condensate polishing system is included or not in PWR and precoatcondensate polishing system, deep bed condensate polishing system in BWR and the 5 waste streams, i. e., compactibIe trash (COTRASH), ion exchange resin (IXRESIN), concentrate liquid (CONCLIQ), filter sludge (FSLUDGE), non compactible trash (COTRASH). This study uses the PVRR and LRR methods to create cost analysis and performs sensitivity analysis for the each cost variables and shows that future burial costs increases are the major factors in the economic evaluation

  14. Technological Advances of Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Lazarev, Ruslan; Top, Søren; Grønbæk, Jens

    The efficient polishing of surfaces is very important in mould and die industry. Fine abrasive processes are widely used in industry for the first steps for the production of tools of high quality in terms of finishing accuracy, form and surface integrity. While manufacturing of most components....... In this study, the influence of polishing parameters and type of polishing media on fine abrasive surface finishing is investigated. Experimental study is covering 2D rotational surfaces that is widespread used in mould and dies industry. Application of it is essential for process intelligent control, condition...... monitoring and quality inspection....

  15. Use of fundamental condensation heat transfer experiments for the development of a sub-grid liquid jet condensation model

    Energy Technology Data Exchange (ETDEWEB)

    Buschman, Francis X., E-mail: Francis.Buschman@unnpp.gov; Aumiller, David L.

    2017-02-15

    Highlights: • Direct contact condensation data on liquid jets up to 1.7 MPa in pure steam and in the presence of noncondensable gas. • Identified a pressure effect on the impact of noncondensables to suppress condensation heat transfer not captured in existing data or correlations. • Pure steam data is used to develop a new correlation for condensation heat transfer on subcooled liquid jets. • Noncondensable data used to develop a modification to the renewal time estimate used in the Young and Bajorek correlation for condensation suppression in the presence of noncondensables. • A jet injection boundary condition, using a sub-grid jet condensation model, is developed for COBRA-IE which provides a more detailed estimate of the condensation rate on the liquid jet and allows the use of jet specific closure relationships. - Abstract: Condensation on liquid jets is an important phenomenon for many different facets of nuclear power plant transients and analyses such as containment spray cooling. An experimental facility constructed at the Pennsylvania State University, the High Pressure Liquid Jet Condensation Heat Transfer facility (HPLJCHT), has been used to perform steady-state condensation heat transfer experiments in which the temperature of the liquid jet is measured at different axial locations allowing the condensation rate to be determined over the jet length. Test data have been obtained in a pure steam environment and with varying concentrations of noncondensable gas. This data extends the available jet condensation data from near atmospheric pressure up to a pressure of 1.7 MPa. An empirical correlation for the liquid side condensation heat transfer coefficient has been developed based on the data obtained in pure steam. The data obtained with noncondensable gas were used to develop a correlation for the renewal time as used in the condensation suppression model developed by Young and Bajorek. This paper describes a new sub-grid liquid jet

  16. Use of fundamental condensation heat transfer experiments for the development of a sub-grid liquid jet condensation model

    International Nuclear Information System (INIS)

    Buschman, Francis X.; Aumiller, David L.

    2017-01-01

    Highlights: • Direct contact condensation data on liquid jets up to 1.7 MPa in pure steam and in the presence of noncondensable gas. • Identified a pressure effect on the impact of noncondensables to suppress condensation heat transfer not captured in existing data or correlations. • Pure steam data is used to develop a new correlation for condensation heat transfer on subcooled liquid jets. • Noncondensable data used to develop a modification to the renewal time estimate used in the Young and Bajorek correlation for condensation suppression in the presence of noncondensables. • A jet injection boundary condition, using a sub-grid jet condensation model, is developed for COBRA-IE which provides a more detailed estimate of the condensation rate on the liquid jet and allows the use of jet specific closure relationships. - Abstract: Condensation on liquid jets is an important phenomenon for many different facets of nuclear power plant transients and analyses such as containment spray cooling. An experimental facility constructed at the Pennsylvania State University, the High Pressure Liquid Jet Condensation Heat Transfer facility (HPLJCHT), has been used to perform steady-state condensation heat transfer experiments in which the temperature of the liquid jet is measured at different axial locations allowing the condensation rate to be determined over the jet length. Test data have been obtained in a pure steam environment and with varying concentrations of noncondensable gas. This data extends the available jet condensation data from near atmospheric pressure up to a pressure of 1.7 MPa. An empirical correlation for the liquid side condensation heat transfer coefficient has been developed based on the data obtained in pure steam. The data obtained with noncondensable gas were used to develop a correlation for the renewal time as used in the condensation suppression model developed by Young and Bajorek. This paper describes a new sub-grid liquid jet

  17. Thermal stability of chloroform in the steam condensate cycle of CANDU-PHW nuclear power plant

    International Nuclear Information System (INIS)

    Lepine, Louis; Gilbert, Roland; Ouellet, Lorenzo

    1992-01-01

    Analysis of samples taken at the Gentilly 2 (Quebec) CANDU-PHW (CANadian Deuterium Uranium - Pressurized Heavy Water) plant after chlorination and demineralization revealed the presence of all four trihalomethanes (THMs) (CHCl 3 , CHBrCl 2 , CHBr 2 Cl and CHBr 3 ) and other unidentified halogenated volatile compounds. Among the THMs, chloroform was the major contaminant. A study of its thermal stability in water at different temperatures confirmed the degradation of the CHCl 3 molecule according to the equation CHCl 3 + H2O → CO + 3 HCl. The reaction follows first order kinetics and has an activation energy of 100 kJ/mol. The estimated half-life is six seconds at 260 deg C, the maximum temperature of the steam condensate cycle

  18. BWR condensate filtration studies

    International Nuclear Information System (INIS)

    Wilson, J.A.; Pasricha, A.; Rekart, T.E.

    1993-09-01

    Poor removal of particulate corrosion products (especially iron) from condensate is one of the major problems in BWR systems. The presence of activated corrosion products creates ''hot spots'' and increases piping dose rates. Also, fuel efficiency is reduced and the risk of fuel failure is increased by the deposit of corrosion products on the fuel. Because of these concerns, current EPRI guidelines call for a maximum of 2 ppb of iron in the reactor feedwater with a level of 0.5 ppb being especially desirable. It has become clear that conventional deep bed resins are incapable of meeting these levels. While installation of prefilter systems is an option, it would be more economical for plants with naked deep beds to find an improved bead resin for use in existing systems. BWR condensate filtration technologies are being tested on a condensate side stream at Hope Creek Nuclear Generating Station. After two years of testing, hollow fiber filters (HFF) and fiber matrix filters (FMF), and low crosslink cation resin, all provide acceptable results. The results are presented for pressure drop, filtration efficiency, and water quality measurements. The costs are compared for backwashable non-precoat HFF and FMF. Results are also presented for full deep bed vessel tests of the low crosslink cation resin

  19. Physical-chemistry aspects of water in steam turbines associated with material stress and electrochemical assessment of the AISI 403 to simulate real condition

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, D S; Franco, C V; Godinho, J F; Frech, W A; Sonai, G G [Univ. Federal de Santa Catarina, Florianopolis (Brazil); Torres, L A.M.; Ellwanger, A R.F. [Tractebel Energia, Capivari de Baixo (Brazil)

    2009-07-01

    This study described a methodology developed to prevent the occurrence of corrosion failure in steam turbines. The methodology was developed after the failure of a turbine blade at a plant in Brazil. Deposits were collected from various locations along the turbine blade path and analyzed. A turbine deposit collector and simulator was installed to determine the concentrations of steam impurities. Samples were collected from the low pressure turbine at the crossover point and from the polishing station and analyzed using inductive coupled plasma-mass spectrometry (ICP-MS) in order to determine if sodium levels exceeded 3 ppb. Filters were weighed in order to determine the accumulation of impurities. A 3-electrode system was used to determine the influence of chloride ions. The design of the system's condensate polisher beds was modified in order to improve condensate effluent conductivity. The condensate treatment procedure lowered the concentrations of salt impurities and established a monitoring methodology for water and steam used at the plant. It was concluded that the methodology can be used to to reduce inspection intervals and increase system reliability. 10 refs., 1 tab., 7 figs.

  20. Fiscal 1981 Sunshine Project research report. Development of hydrothermal power plant. Development of binary cycle power plant. Conceptual plant design; 1981 nendo nessui riyo hatsuden plant no kaihatsu / binary cycle hatsuden plant no kaihatsu seika hokokusho . Plant gainen sekkei

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1982-03-01

    Conceptual design was made on a 10MW class binary cycle power plant for a demonstration plant superior in reliability and profitability, under most realistic current geothermal field conditions. In the design, study was made on heat balance, main pipe system, equipment allocation, and electric system for a plant system configuration, and study was also made on preheater, evaporator, condenser, turbine and others for plant component equipment. Further study was made on optimization of mist cooling condenser, instrumentation, control, utility, and environmental measures. The following basic data were obtained through the conceptual design: plant inlet hot water temperature: 130 degrees C, plant outlet hot water temperature: 70 degrees C, hot water flow rate: 1,415t/h, working fluid: R-114, R-114 pressure in evaporator: 11.98kg/cm{sup 2} abs, R-114 evaporation temperature: 91.1 degrees C, R-114 condensation temperature: 31.0 degrees C, R- 114 flow rate: 2,265t/h, site area: 106.5m x 102.4m, building area: 48.7m x 16.8m, and building height: 13.0m. (NEDO)

  1. Bench scale experiments for the remediation of Hanford Waste Treatment Plant low activity waste melter off-gas condensate

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, Kathryn M.L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Poirier, Michael [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, Daniel J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-08-11

    The Low Activity Waste (LAW) vitrification facility at the Hanford Waste Treatment and Immobilization Plant (WTP) will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The plan for disposition of this stream during baseline operations is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. The primary reason to recycle this stream is so that the semi-volatile 99Tc isotope eventually becomes incorporated into the glass. This stream also contains non-radioactive salt components that are problematic in the melter, so diversion of this stream to another process would eliminate recycling of these salts and would enable simplified operation of the LAW melter and the Pretreatment Facilities. This diversion from recycling this stream within WTP would have the effect of decreasing the LAW vitrification mission duration and quantity of glass waste. The concept being tested here involves removing the 99Tc so that the decontaminated aqueous stream, with the problematic salts, can be disposed elsewhere.

  2. Waste Treatment and Immobilization Plant U. S. Department of Energy Office of River Protection Submerged Bed Scrubber Condensate Disposition Project - 13460

    Energy Technology Data Exchange (ETDEWEB)

    Yanochko, Ronald M. [Washington River Protection Solutions, P.O. Box 850, Richland, Washington 99352 (United States); Corcoran, Connie [AEM Consulting, LLC, 1201 Jadwin Avenue, Richland, Washington 99352 (United States)

    2013-07-01

    The Hanford Waste Treatment and Immobilization Plant (WTP) will generate an off-gas treatment system secondary liquid waste stream [submerged bed scrubber (SBS) condensate], which is currently planned for recycle back to the WTP Low Activity Waste (LAW) melter. This SBS condensate waste stream is high in Tc-99, which is not efficiently captured in the vitrified glass matrix [1]. A pre-conceptual engineering study was prepared in fiscal year 2012 to evaluate alternate flow paths for melter off-gas secondary liquid waste generated by the WTP LAW facility [2]. This study evaluated alternatives for direct off-site disposal of this SBS without pre-treatment, which mitigates potential issues associated with recycling. This study [2] concluded that SBS direct disposal is a viable option to the WTP baseline. The results show: - Off-site transportation and disposal of the SBS condensate is achievable and cost effective. - Reduction of approximately 4,325 vitrified WTP Low Activity Waste canisters could be realized. - Positive WTP operational impacts; minimal WTP construction impacts are realized. - Reduction of mass flow from the LAW Facility to the Pretreatment Facility by 66%. - Improved Double Shell Tank (DST) space management is a benefit. (authors)

  3. Transfer of gaseous iodine from atmosphere to rough rice, brown rice and polished rice

    International Nuclear Information System (INIS)

    Sumiya, Misako; Uchida, Shigeo; Muramatsu, Yasuyuki; Ohmomo, Yoichiro; Yamaguchi, Shuho; Obata, Hitoshi.

    1987-01-01

    Experiments were carried out in order to obtain information required for establishing transfer coefficients of gaseous iodine (I 2 ) to rough rice, brown rice and polished rice. The gaseous iodine deposited on young rice plants before the heading period was scarcely found in the rough rice harvested at the full ripe stage. The biological half life of iodine in hull, however, was much slower than that in leaves of 14 days. The translocation of iodine from leaves and stalks to rough rice was not clearly recognized. Therefore, it was deduced that iodine found in brown rice mainly should originate from that deposited on the hull. The distribution ratios of iodine between rough rice and brown rice, and between brown rice and polished rice were 100:4 and 100:30 on 100 grains basis, respectively. If average normalized deposition velocity (V d(m) ) or derived deposition velocity (V s ) are given, the transfer coefficients of gaseous iodine to rough rice (TF r ), brown rice (TF b ) and polished rice (TF p ) could be calculated. (author)

  4. The Polish Mother on the defensive? The transformation of the myth and its impact on the motherhood of Polish women

    Directory of Open Access Journals (Sweden)

    Agnieszka Imbierowicz

    2012-06-01

    Full Text Available The subject of this presentation is the attempt to define and to present the origins, socio-cultural content and the evolution of The Polish Mother myth, present in the polish national consciousness. The author tries to show how this myth was born, what functions it fulfilled and what forms it took in the changing historical and social reality, from the moment of loss of independence, through a period of real socialism, until the present day. The impact of this myth in the lives of real women and their motherhood is taken into consideration. Then, the author comparing the results of the latest polish sociological researches on the family and its transformation, and transformation of value systems together with theories about the specifics of life in the period of postmodernity, wonders whether it’s time to deconstruct the myth of The Polish Mother, because it does not fit the conditions of today’s world, which is characterized, above all, by the apotheosis of individuality, self-realization and freedom, or perhaps in polish society there is still strong traditionalism in thinking about motherhood, and the myth of The Polish Mother is still alive?

  5. Effect of polishing instruments and polishing regimens on surface topography and phase transformation of monolithic zirconia: An evaluation with XPS and XRD analysis.

    Science.gov (United States)

    Al-Haj Husain, Nadin; Camilleri, Josette; Özcan, Mutlu

    2016-12-01

    Polishing procedures might alter monolithic zirconia (MZ) surface resulting in phase changes that can be deleterious for clinical performance and antagonist tooth wear. This study investigated the topographical features and phase transformation in MZ after polishing with different regimens simulating the clinical workflow. ​ MZ specimens (Katana Zirconia HT, Kuraray-Noritake) (12×12×1.8 mm(3)) were grinded and polished using one of the five systems assessed: BG: Silicone carbide polishers (Brownie, Greenie, Super Greenie); CG: Diamond impregnated ceramic polisher kit (Ceragloss); EV: Synthetically bonded grinder interspersed with diamond (EVE Kit); SL: Urethane coated paper with aluminium oxide grits (Soflex Finishing and Polishing System Kit) and DB: Diamond bur (8 µm). Polished specimens were initially roughened with 220 µm diamond burs (Grinding Bur-GB) (10 s, 160.000160,000 rpm) and considered for baseline measurements. Polishing regimens were performed for 10 s using a slow-speed hand piece under water-cooling except for SL, in a custom made device (750 g; 5000 and 75,000 rpm). Surface roughnesses, phase changes (XRD) were assessed, surface characterization was performed (SEM, EDS). The highest roughness was obtained with the EV system (1.11 µm) compared to those of other systems (0.13-0.4 µm) (pθ and minor peak at 34.94°2θ. While GB, CG, EV, SL and DB exhibited a peak shift to the left, BG demonstrated a right peak shift on the 2θ scale. Monoclinic phase change was not noted in any of the groups. All polishing methods, except BG, exhibited a peak shift towards the lower angles of the 2-theta scale. Since the peak shifts were in the order of fractions of an angle they are attributed to stress formation rather than a phase change in the material. Thus, all polishing systems tested may not be detrimental for the phase transformation of MZ. EV system resulted in the highest roughness and none of the polishing regimens restored the polishability to the

  6. Near term feasibility of nuclear reactor for sea-water desalting: coupling of standard condensing nuclear power stations to low grade heat multieffect distillation plants

    International Nuclear Information System (INIS)

    Adar, J.; Manor, S.; Schaal, M.

    1977-01-01

    Commercial nuclear power reactors exist only in standard sizes and designs. No large nuclear back-pressure turbines are available today. Therefore, near term large scale nuclear desalination plants must be tailored to the NSSS sizes and available turbines and not the contrary. Standard condensing nuclear turbines could operate continuously with a back-presure of up to 5-7'' Hg (depending on the supplier). It means that they can exhaust huge amounts of steam at 56 0 C - 64 0 C with a loss of electricity production of 6% - 10% when compared to 2 1/2'' Hg normal condensing pressure. The horizontal aluminium tube multi-effect distillation process developed by ''Israel Desalination Engineering'' Ltd. is very suitable for the use of such low-grade heat: 4 to 9 effects can operate within these temperature ranges. A special flash-chamber constitutes a positive barrier against any possible contamination being carried over by the steam exhausted from the turbine to the desalination plant. Flow sheets, heat and mass balances have been prepared for two standard sizes of NSSS and turbines (1882sup(Mwth) and 2785sup(Mwth)), two ''back-pressures'' (5 1/2'' and 7'' Hg), and corresponding desalination plants. Only standard equipment is being used in the steam and electricity producing plant. The desalination plant consists of 6 to 12 parallel double lines, each of them similar to a large prototype now being designed and which is going to be coupled to an old fossil power station. Water production varies between 50 and 123 sup(us MGD) and water cost between 23 and 36 sup(cents)/M 3 . Total energy requirements of the desalination plant represent only 19 to 50% of the total water cost as against 75% for a single purpose plant. Costs are based on actual bids for the power plant and actual estimates for the desalination prototype. The operation is designed to be flexible so that the power plant can be operated either in conjunction with the desalination plant, or as a single purpose

  7. Chemical mode control in nuclear power plant decommissioning during operation of technologies in individual radioactive waste processing plants

    International Nuclear Information System (INIS)

    Horvath, J.; Dugovic, L.

    1999-01-01

    Sewage treatment of nuclear power plant decommissioning is performed by system of sewage concentration in evaporator with formation of condensed rest, it means radioactive waste concentrate and breeding steam. During sewage treatment plant operation department of chemical mode performs chemical and radiochemical analysis of sewage set for treatment, chemical and radiochemical analysis of breeding steam condensate which is after final cleaning on ionization filter and fulfilling the limiting conditions released to environment; chemical and radiochemical analysis of heating steam condensate which is also after fulfilling the limiting conditions released to environment. Condensed radioactive concentrate is stored in stainless tanks and later converted into easy transportable and chemically stable matrix from the long term storage point of view in republic storage Mochovce. The article also refer to bituminous plant, vitrification plant, swimming pool decontamination plant of long term storage and operation of waste processing plant Bohunice

  8. CONDENSATION OF WATER VAPOR IN A VERTICAL TUBE CONDENSER

    Directory of Open Access Journals (Sweden)

    Jan Havlík

    2015-10-01

    Full Text Available This paper presents an analysis of heat transfer in the process of condensation of water vapor in a vertical shell-and-tube condenser. We analyze the use of the Nusselt model for calculating the condensation heat transfer coefficient (HTC inside a vertical tube and the Kern, Bell-Delaware and Stream-flow analysis methods for calculating the shell-side HTC from tubes to cooling water. These methods are experimentally verified for a specific condenser of waste process vapor containing air. The operating conditions of the condenser may be different from the assumptions adopted in the basic Nusselt theory. Modifications to the Nusselt condensation model are theoretically analyzed.

  9. Condensate recovery by cycling at declining pressures

    Energy Technology Data Exchange (ETDEWEB)

    Havlena, Z G; Griffith, J D; Pot, R; Kiel, O G

    1967-06-05

    Cycling condensate reservoirs under conditions of declining pressure, rather than constant pressure, is advantageous from both a recovery and an economic standpoint. Wet gas displaced from the swept areas is recovered concurrently with wet gas recovered by gas expansion from the unswept portions of the reservoir. Any liquid condensed in the swept areas is revaporized by dry injection gas and recovered as an enriched gas. By this mode of operation, high condensate recovery is obtained, gas sales may be possible at an earlier stage of depletion, more flexibility in field and plant operations is feasible and reduction of 15% in investment and operating costs is achieved. Injection gas requirements are reduced by 40%. The Windfall reservoir in Canada has been successfully produced in this manner, starting in 1962. It is a typical retrograde type reservoir which in 1965 represented 15% of reservoirs exploited in North America.

  10. Best available technology equivalent controls for B Plant Process Condensate: Tank farm process technology section

    International Nuclear Information System (INIS)

    1988-11-01

    This report evaluates whether proposed controls for the B Plant Process Condensate effluent stream are equivalent to Best Available Technology (BAT) economically achievable. Methods to determine whether the proposed controls for the BCP were equivalent to BAT originated from the Guidance Document for the Hanford Site. The BAT performance standards, which originate from the Clean Water Act, are to be applied to all contaminated liquid effluent discharges currently going to the soil column at the Hanford Site. The B Plant BAT evaluation addressed pollutants that had not been regulated traditionally under Federal or State water-pollution control programs. As a result, only comparisons could be made to existing radiation and water quality standards, and a BAT determination based on the effluent guidelines method (as outlined in the BAT Guidance Document) was not possible. Due to the variability and inconsistency of factors with comparable streams, such as the effluent stream at the Savannah River Plant, a BAT determination by the technology transfer method and treatability studies method was not possible. By using the generic treatment systems method, a one-or two-stage treatment system for dissolved solids removal was concluded to be equivalent to BAT. By performing two economic achievability tests, a one-stage treatment system consisting of mixed bed ion exchange columns was considered to be cost effective and equivalent to BAT. 13 refs., 4 figs., 5 tabs

  11. Chemical Mechanical Polishing Optimization for 4H-SiC

    National Research Council Canada - National Science Library

    Neslen, Craig

    2000-01-01

    .... Preliminary chemical mechanical polishing (CMP) studies of 1 3/8" 4H-SiC wafers were performed in an attempt to identify the polishing parameter values that result in a maximum material removal rate and thus reduce substrate polishing time...

  12. Laser polishing of 3D printed mesoscale components

    International Nuclear Information System (INIS)

    Bhaduri, Debajyoti; Penchev, Pavel; Batal, Afif; Dimov, Stefan; Soo, Sein Leung; Sten, Stella; Harrysson, Urban; Zhang, Zhenxue; Dong, Hanshan

    2017-01-01

    Highlights: • Process optimisation for laser polishing novel 3D printed SS316L parts. • Evaluating the effects of key polishing parameters on SS316L surface roughness. • Detailed spectroscopic analysis of oxide layer formation due to laser polishing. • Comparative surface integrity analysis of SS parts polished in air and argon. • A maximum reduction in roughness of over 94% achieved at optimised polishing settings. - Abstract: Laser polishing of various engineered materials such as glass, silica, steel, nickel and titanium alloys, has attracted considerable interest in the last 20 years due to its superior flexibility, operating speed and capability for localised surface treatment compared to conventional mechanical based methods. The paper initially reports results from process optimisation experiments aimed at investigating the influence of laser fluence and pulse overlap parameters on resulting workpiece surface roughness following laser polishing of planar 3D printed stainless steel (SS316L) specimens. A maximum reduction in roughness of over 94% (from ∼3.8 to ∼0.2 μm S_a) was achieved at the optimised settings (fluence of 9 J/cm"2 and overlap factors of 95% and 88–91% along beam scanning and step-over directions respectively). Subsequent analysis using both X-ray photoelectron spectroscopy (XPS) and glow discharge optical emission spectroscopy (GDOES) confirmed the presence of surface oxide layers (predominantly consisting of Fe and Cr phases) up to a depth of ∼0.5 μm when laser polishing was performed under normal atmospheric conditions. Conversely, formation of oxide layers was negligible when operating in an inert argon gas environment. The microhardness of the polished specimens was primarily influenced by the input thermal energy, with greater sub-surface hardness (up to ∼60%) recorded in the samples processed with higher energy density. Additionally, all of the polished surfaces were free of the scratch marks, pits, holes, lumps

  13. Laser polishing of 3D printed mesoscale components

    Energy Technology Data Exchange (ETDEWEB)

    Bhaduri, Debajyoti, E-mail: debajyoti.bhaduri@gmail.com [Department of Mechanical Engineering, School of Engineering, University of Birmingham, Edgbaston, Birmingham, B15 2TT (United Kingdom); Penchev, Pavel; Batal, Afif; Dimov, Stefan; Soo, Sein Leung [Department of Mechanical Engineering, School of Engineering, University of Birmingham, Edgbaston, Birmingham, B15 2TT (United Kingdom); Sten, Stella; Harrysson, Urban [Digital Metal, Höganäs AB, 263 83 Höganäs (Sweden); Zhang, Zhenxue; Dong, Hanshan [School of Metallurgy and Materials, University of Birmingham, Edgbaston, Birmingham, B15 2TT (United Kingdom)

    2017-05-31

    Highlights: • Process optimisation for laser polishing novel 3D printed SS316L parts. • Evaluating the effects of key polishing parameters on SS316L surface roughness. • Detailed spectroscopic analysis of oxide layer formation due to laser polishing. • Comparative surface integrity analysis of SS parts polished in air and argon. • A maximum reduction in roughness of over 94% achieved at optimised polishing settings. - Abstract: Laser polishing of various engineered materials such as glass, silica, steel, nickel and titanium alloys, has attracted considerable interest in the last 20 years due to its superior flexibility, operating speed and capability for localised surface treatment compared to conventional mechanical based methods. The paper initially reports results from process optimisation experiments aimed at investigating the influence of laser fluence and pulse overlap parameters on resulting workpiece surface roughness following laser polishing of planar 3D printed stainless steel (SS316L) specimens. A maximum reduction in roughness of over 94% (from ∼3.8 to ∼0.2 μm S{sub a}) was achieved at the optimised settings (fluence of 9 J/cm{sup 2} and overlap factors of 95% and 88–91% along beam scanning and step-over directions respectively). Subsequent analysis using both X-ray photoelectron spectroscopy (XPS) and glow discharge optical emission spectroscopy (GDOES) confirmed the presence of surface oxide layers (predominantly consisting of Fe and Cr phases) up to a depth of ∼0.5 μm when laser polishing was performed under normal atmospheric conditions. Conversely, formation of oxide layers was negligible when operating in an inert argon gas environment. The microhardness of the polished specimens was primarily influenced by the input thermal energy, with greater sub-surface hardness (up to ∼60%) recorded in the samples processed with higher energy density. Additionally, all of the polished surfaces were free of the scratch marks, pits, holes

  14. Polish Qualitative Sociology: The General Features and Development

    OpenAIRE

    Konecki, Krzysztof Tomasz

    2005-01-01

    The article explores the development of Polish qualitative sociology in Poland by presenting its main intellectual routes and some of the general features of Polish sociology. Romanticism and inductionmethod are crucial elements for the development of this discipline in Poland and contribute to its. unigueness. The role of Florian Znaniecki in creating the Polish qualitative sociology is also underlined. Krzysztof Konecki

  15. Sensing roughness and polish direction

    DEFF Research Database (Denmark)

    Jakobsen, Michael Linde; Olesen, Anders Sig; Larsen, Henning Engelbrecht

    2016-01-01

    As a part of the work carried out in a project supported by the Danish Council for Technology and Innovation, we have investigated the option of smoothing standard CNC-machined surfaces. In the process of constructing optical prototypes, involving custom-designed optics, the development cost...... and time consumption can become prohibitive in a research budget. Machining the optical surfaces directly is expensive and time consuming. Alternatively, a more standardized and cheaper machining method can be used, calling for the object to be manually polished. During the polishing process, the operator...... needs information about the RMS-value of the surface roughness and the current direction of the scratches introduced by the polishing process. The RMS-value indicates to the operator how far he is from the final finish, and the scratch orientation is often specified by the customer in order to avoid...

  16. Morphological, Phenological And Agronomical Characterisation Of Variability Among Common Bean (Phaseolus Vulgaris L. Local Populations From The National Centre For Plant Genetic Resources: Polish Genebank

    Directory of Open Access Journals (Sweden)

    Boros Lech

    2014-12-01

    Full Text Available The main purpose of this work was to analyse the morphological, phenological and agronomical variability among common bean local populations from The National Centre for Plant Genetic Resources, Polish Genebank, in order to know the relation among them, and to identify potentially useful accessions for future production and breeding. A considerable genotypic variation for number of seeds per plant, number of pods per plant and weight of seeds per plant were found. Studied bean accessions differed significantly in terms of thousand seeds weight (TSW as well as severity of bacterial halo blight and anthracnose, the major bean diseases. The lowest genotypic diversity was found for the percentage of protein in the seeds, the length of the vegetation period and lodging. The cluster analysis allowed identification of five groups of bean accessions. Genotypes from the first cluster (POLPOD 98-77, KOS 002 and Raba cv. and from the second cluster (WUKR 06-573a, KRA 4, WUKR 06-0534 together with Prosna cv. are of the highest usefulness for breeding purposes. There was no grouping of local populations depending on region of origin.

  17. Steam condenser

    International Nuclear Information System (INIS)

    Masuda, Fujio

    1980-01-01

    Purpose: To enable safe steam condensation by providing steam condensation blades at the end of a pipe. Constitution: When high temperature high pressure steam flows into a vent pipe having an opening under water in a pool or an exhaust pipe or the like for a main steam eacape safety valve, non-condensable gas filled beforehand in the steam exhaust pipe is compressed, and discharged into the water in the pool. The non-condensable gas thus discharged from the steam exhaust pipe is introduced into the interior of the hollow steam condensing blades, is then suitably expanded, and thereafter exhausted from a number of exhaust holes into the water in the pool. In this manner, the non-condensable gas thus discharged is not directly introduced into the water in the pool, but is suitable expanded in the space of the steam condensing blades to suppress extreme over-compression and over-expansion of the gas so as to prevent unstable pressure vibration. (Yoshihara, H.)

  18. The common project for completion of Bubbler Condenser Qualification (Bohunice, Mochovce, Dukovany and Paks NPPs)

    International Nuclear Information System (INIS)

    Jaroslav, H.; Pavol, B.

    2003-01-01

    Described is the common project for completion of bubbler condenser qualification for nuclear power plants in Bohunice, Mochovice, Dukovany and Paks. Functionality of the bubbler condenser was elaborated during the simulation of the main steam line brake, medium break and small break LOCA. On this basis the appropriate operation of bubbler condenser containment under accident conditions can be positively confirmed

  19. Uptake and distributions of 90Sr and 137Cs in rice plants

    International Nuclear Information System (INIS)

    Tsukada, Hirofumi; Takeda, Akira; Hasegawa, Hidenao

    2008-01-01

    Polished rice is a staple food in Asian countries and ingestion of polished rice is one of the most important pathways of radionuclides into humans. Inedible parts of rice plants are returned to the soil as fertilizer and are used as an ingredient of feed for livestock. Strontium-90 and 137 Cs are important radionuclides for the assessment of radiation exposure to the public because of their high fission yield, long-half lives and transferability in the environment. The purpose of the present study is to obtain information on the distributions of 90 Sr and 137 Cs in rice plant components for better understanding of the fate of the radionuclides in an agricultural environment. Rice plants were cultivated in an experimental field and collected at harvest time. The concentrations of 90 Sr and 137 Cs in the soil were 5.6 and 4.4 Bq kg -1 , respectively. Rice plant samples were separated into polished rice, rice bran, hull, straw and root parts, and then the concentrations of 90 Sr and 137 Cs in the samples were determined. The concentrations of 90 Sr and 137 Cs in polished rice were 0.012 and 0.0048 Bq kg -1 dry weight, respectively. The concentrations of 90 Sr and 137 Cs varied by two and one orders of magnitudes in rice plant components, respectively. The edible component, polished rice, accounted for 32% of the total dry weight. In the entire rice plants, only 0.5% of the total 90 Sr and 10% of the total 137 Cs were found in polished rice. Contents of 90 Sr and 137 Cs in the above ground parts were 0.84 and 0.021 Bq m -2 , respectively. For each cropping, the percentages of 90 Sr and 137 Cs uptake from the upper soil layer to the aboveground biomass of rice plants were calculated as 0.094 and 0.0030% of their soil inventories, respectively. (author)

  20. Effects of polishing procedures on color stability of composite resins

    Directory of Open Access Journals (Sweden)

    Ahmet Umut Güler

    2009-04-01

    Full Text Available The purpose of this study was to investigate the effect of different polishing methods on color stability of posterior, universal and nanohybrid composite resin restorative materials upon exposure to a staining agent. Twenty-five specimens were prepared for each of 5 different composite resins (Filtek Z250, Filtek P60, Quadrant LC, Grandio and Filtek Supreme. Specimens were divided into 5 groups and different polishing procedures, including polishing discs (Pd, polishing discs then diamond polishing paste (PdP, polishing discs then a liquid polishing system (Biscover (PdB, and combinations of these (PdPB were used. Unpolished specimens served as the control (C. The specimens were stored for 48 h in a coffee solution. The color of all specimens was measured before and after exposure with a colorimeter, and total color change (DE* were calculated. The data were analyzed with a two-way ANOVA and the means were compared by Tukey HSD test (a=0.05. The lowest color difference was observed in the groups PdP and C, while the highest color difference was observed in PdPB, and PdB. When comparing the five different restorative materials, no significant difference was observed between FiltekP60 and FiltekZ250, and these materials demonstrated significantly less color change than Quadrant LC and the nanohybrid materials (Grandio, Filtek Supreme. The posterior (Filtek P60 and universal (Filtek Z250 composite resin restorative materials, which do not contain tetraethyleneglycol dimethacrylate (TEGDMA, were found to be less stainable than the nanohybrid (Grandio, Filtek Supreme and universal (Quadrant LC composite resins, which contain TEGDMA. The use of diamond polishing paste after polishing with polishing discs significantly decreased staining when compared to the groups that used polishing discs alone, for all restorative materials tested. The highest color change values were obtained for the specimens that were polished with the Biscover liquid polish

  1. Preventing freezing of condensate inside tubes of air cooled condenser

    International Nuclear Information System (INIS)

    Joo, Jeong A; Hwang, In Hwan; Lee, Dong Hwan; Cho, Young Il

    2012-01-01

    An air cooled condenser is a device that is used for converting steam into condensate by using ambient air. The air cooled condenser is prone to suffer from a serious explosion when the condensate inside the tubes of a heat exchanger is frozen; in particular, tubes can break during winter. This is primarily due to the structural problem of the tube outlet of an existing conventional air cooled condenser system, which causes the backflow of residual steam and noncondensable gases. To solve the backflow problem in such condensers, such a system was simulated and a new system was designed and evaluated in this study. The experimental results using the simulated condenser showed the occurrence of freezing because of the backflow inside the tube. On the other hand, no backflow and freezing occurred in the advanced new condenser, and efficient heat exchange occurred

  2. Condensate subcooling near tube exit during horizontal in-tube condensation

    International Nuclear Information System (INIS)

    Hashizume, K.; Abe, N.; Ozeki, T.

    1992-01-01

    In-tube condensation is encountered in various applications for heat exchangers, such as domestic air-conditioning equipment, industrial air-cooled condensers, and moisture separator reheaters (MSRs) for nuclear power pants. Numerous research work has been conducted to predict the condensation heat transfer coefficient, and we have now enough information for thermal design of heat exchangers with horizontal in-tube condensation. Most of the research is analytical and/or experimental work in the annular or stratified flow regime, or experimental work on bulk condensation, i.e., from saturated vapor to complete condensation. On the other hand, there exist few data about the heat transfer phenomena in the very lower-quality region near the tube exit. The purpose of this paper is to clarify the condensation heat transfer phenomena near the tube exit experimentally and analytically, and to predict the degree of condensate subcooling

  3. Polish Semantic Parser

    Directory of Open Access Journals (Sweden)

    Agnieszka Grudzinska

    2000-01-01

    Full Text Available Amount of information transferred by computers grows very rapidly thus outgrowing the average man's capability of reception. It implies computer programs increase in the demand for which would be able to perform an introductory classitication or even selection of information directed to a particular receiver. Due to the complexity of the problem, we restricted it to understanding short newspaper notes. Among many conceptions formulated so far, the conceptual dependency worked out by Roger Schank has been chosen. It is a formal language of description of the semantics of pronouncement integrated with a text understanding algorithm. Substantial part of each text transformation system is a semantic parser of the Polish language. It is a module, which as the first and the only one has an access to the text in the Polish language. lt plays the role of an element, which finds relations between words of the Polish language and the formal registration. It translates sentences written in the language used by people into the language theory. The presented structure of knowledge units and the shape of understanding process algorithms are universal by virtue of the theory. On the other hand the defined knowledge units and the rules used in the algorithms ure only examples because they are constructed in order to understand short newspaper notes.

  4. Microbiological flora and nail polish: a brief report.

    Science.gov (United States)

    Rayan, G M; Flournoy, D J; Schlageter, P

    1994-11-01

    Removing nail polish and prosthetic nails from operating room (OR) personnel prior to scrubbing and from patients prior to hand surgery is recommended but not practiced in many hospitals. There is concern that nail polish can act as a vehicle for the transfer of infectious agents. This study was designed to determine the incidence of microbiological flora of nail polish in a clinical setting.

  5. Smoking characteristics of Polish immigrants in Dublin.

    LENUS (Irish Health Repository)

    Kabir, Zubair

    2008-01-01

    BACKGROUND: This study examined two main hypotheses: a) Polish immigrants\\' smoking estimates are greater than their Irish counterparts (b) Polish immigrants purchasing cigarettes from Poland smoke "heavier" (>\\/= 20 cigarettes a day) when compared to those purchasing cigarettes from Ireland. The study also set out to identify significant predictors of \\'current\\' smoking (some days and everyday) among the Polish immigrants. METHODS: Dublin residents of Polish origin (n = 1,545) completed a previously validated Polish questionnaire in response to an advertisement in a local Polish lifestyle magazine over 5 weekends (July-August, 2007). The Office of Tobacco Control telephone-based monthly survey data were analyzed for the Irish population in Dublin for the same period (n = 484). RESULTS: Age-sex adjusted smoking estimates were: 47.6% (95% Confidence Interval [CI]: 47.3%; 48.0%) among the Poles and 27.8% (95% CI: 27.2%; 28.4%) among the general Irish population (p < 0.001). Of the 57% of smokers (n = 345\\/606) who purchased cigarettes solely from Poland and the 33% (n = 198\\/606) who purchased only from Ireland, 42.6% (n = 147\\/345) and 41.4% (n = 82\\/198) were "heavy" smokers, respectively (p = 0.79). Employment (Odds Ratio [OR]: 2.89; 95% CI: 1.25-6.69), lower education (OR: 3.76; 95%CI: 2.46-5.74), and a longer stay in Ireland (>24 months) were significant predictors of current smoking among the Poles. An objective validation of the self-reported smoking history of a randomly selected sub-sample immigrant group, using expired carbon monoxide (CO) measurements, showed a highly significant correlation coefficient (r = 0.64) of expired CO levels with the reported number of cigarettes consumed (p < 0.0001). CONCLUSION: Polish immigrants\\' smoking estimates are higher than their Irish counterparts, and particularly if employed, with only primary-level education, and are overseas >2 years.

  6. Laboratory Evaporation Testing Of Hanford Waste Treatment Plant Low Activity Waste Off-Gas Condensate Simulant

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, Duane J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Nash, Charles A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, Daniel J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Crawford, Charles L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Wilmarth, William R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2014-01-01

    The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream, LAW Off-Gas Condensate, from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of canistered glass waste forms. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to be within acceptable concentration ranges in the LAW glass. Diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task examines the impact of potential future disposition of this stream in the Hanford tank farms, and investigates auxiliary evaporation to enable another disposition path. Unless an auxiliary evaporator is used, returning the stream to the tank farms would require evaporation in the 242-A evaporator. This stream is expected to be unusual because it will be very high in corrosive species that are volatile in the melter

  7. Laboratory Evaporation Testing Of Hanford Waste Treatment Plant Low Activity Waste Off-Gas Condensate Simulant

    International Nuclear Information System (INIS)

    Adamson, Duane J.; Nash, Charles A.; McCabe, Daniel J.; Crawford, Charles L.; Wilmarth, William R.

    2014-01-01

    The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream, LAW Off-Gas Condensate, from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of canistered glass waste forms. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to be within acceptable concentration ranges in the LAW glass. Diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task examines the impact of potential future disposition of this stream in the Hanford tank farms, and investigates auxiliary evaporation to enable another disposition path. Unless an auxiliary evaporator is used, returning the stream to the tank farms would require evaporation in the 242-A evaporator. This stream is expected to be unusual because it will be very high in corrosive species that are volatile in the melter

  8. Reel-to-reel substrate tape polishing system

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  9. Using helical compressors for coke gas condensation

    Energy Technology Data Exchange (ETDEWEB)

    Privalov, V E; Rezunenko, Yu I; Lelyanov, N V; Zarnitzkii, G Eh; Gordienko, A A; Derebenko, I F; Venzhega, A G; Leonov, N P; Gorokhov, N N

    1982-08-01

    Coke oven gas compression is discussed. Presently used multilevel piston compressors are criticized. The paper recommends using helical machines which combine advantages of using volume condensing compressors and compact high-efficiency centrifugal machines. Two kinds of helical compressors are evaluated: dry and oil-filled; their productivities and coke oven gas chemical composition are analyzed. Experiments using helical compressors were undertaken at the Yasinovskii plant. Flowsheet of the installation is shown. Performance results are given in a table. For all operating conditions content of insolubles in oil compounds is found to be lower than the acceptable value (0.08%). Compressor productivity measurements with variable manifold pressure are evaluated. Figures obtained show that efficient condensation of raw coke oven gas is possible. Increasing oil-filled compressor productivity is recommended by decreasing amount of oil injected and simultaneously increasing rotation speed. The dry helical compressor with water seal is found to be most promising for raw coke oven gas condensation. (10 refs.)

  10. Polish Qualitative Sociology: The General Features and Development

    OpenAIRE

    Konecki, Krzysztof Tomasz; Kacperczyk, Anna; Marciniak, Łukasz

    2005-01-01

    Forum Qualitative Sozialforschung / Forum: Qualitative Social Research,2005, 6(3) The article explores the development of Polish qualitative sociology in Poland by presenting its main intellectual routes and some of the general features of Polish sociology. Romanticism and inductionmethod are crucial elements for the development of this discipline in Poland and contribute to its. unigueness. The role of Florian Znaniecki in creating the Polish qualitative sociology is also underlined.

  11. Experimental determinations of the turbine condenser operation at Cernavoda NPP Unit 1

    International Nuclear Information System (INIS)

    Romascu, Gabriel; Dragusin, Dumitru; Rogociu, Ioan; Macodean, Luminita; Marciulescu, George

    1999-01-01

    The condenser system represents one of the most important BOP (balance of plant) systems of the CANDU 700 MW Unit at Cernavoda NPP. The paper presents theoretical calculation elements, mathematical model for simulation of condenser operation and the results obtained by model implementation as compared to operation data. The model could be adapted to other turbine and operation regime types. (authors)

  12. Update on the modernization of 200 MW hard coal power plants in Poland

    International Nuclear Information System (INIS)

    Szabo, T.E.; Kopec, M.

    1993-01-01

    In June 1990, the Coalition of 200 MW, Hard Coal, Polish Power Plants representing an installed base of 10,240 MW, including 45 units of 200 MW, signed an agreement with the Westinghouse Electric Corporation, Power Generation Business Unit, based in Orlando, Florida, to cooperate on developing a modernization program for the 200 MW units. Program funding was obtained with The United States Trade Development Program (TDP) providing approximately 2/3 of the cost, and the balance provided by Westinghouse. On March 5, 1992, the Polish-American (51% Westinghouse, 49% Seven (7) Hard Coal Power Plants), Joint Venture Company, MODELPOL, Ltd. (Polish acronym for 'MODernizacja ELektrowni POLskich' or Modernization of Polish Power Plants) was established with the goal to implement not only technically but financially the recommendations of the Modernization Study. The mission given MODELPOL, Ltd. by their Polish-American Shareholders was to: develop the specific modernization programs for each hard coal power plant; assist in identifying and obtaining the financial resources required for implementation; and provide technological preventative maintenance services to improve unit availability. Within these aims was the target to reduce SO 2 , and particulate emissions. The first program is taking place at the Laziska Power Plant, followed by Rybnik. Further projects are in the planning stages. Finance is a constant problem, this should be eased by the restructuring of the power industry. Future programmes include connection to the European Community Power Grid. 5 figs

  13. 21 CFR 872.6030 - Oral cavity abrasive polishing agent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oral cavity abrasive polishing agent. 872.6030... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing agent. (a) Identification. An oral cavity abrasive polishing agent is a device in paste or powder form...

  14. Uptake and distribution of 137Cs, stable Cs and K in rice plants

    International Nuclear Information System (INIS)

    Tsukada, Hirofumi; Hasegawa, Hidenao

    2003-01-01

    The uptake and distributions of 137 Cs, stable Cs and K were determined for rice plant components, including polished rice, rice bran, hulls, leaves, stems, and roots. The distribution of 137 Cs in polished rice and rice bran was similar to that of stable Cs, while that of K was different. The concentration ratios of Cs/K in leaves increased in older leaf blade positions, which meant that the translocation rate of stable Cs, was slower than that of K. At harvest the dry weight of polished rice accounted for 34% of the entire rice plant, while the distributions of stable Cs in the polished rice and the non-edible parts were 7 and 93%, respectively. These findings suggest that the transfer and distribution of stable Cs in rice plants are different from those of K, and the behavior of stable Cs provides a useful analogue in predicting the fate of 137 Cs in an agricultural environment. (author)

  15. Analysis for a PRHRS Condensation Heat Exchanger of the SMART-P Plant

    International Nuclear Information System (INIS)

    Lee, Kwon-Yeong; Kim, Moo Hwan

    2007-01-01

    When an emergency such as the unavailability of feedwater or the loss of off-site power arises with SMART-P, the PRHRS passively removes the core decay heat via natural convection. The system is connected to the feedwater and steam pipes and consists of a heat exchanger submerged in a refueling water tank, a compensation tank, and check and isolation valves. The heat exchanger removes the heat from the reactor coolant system through a steam generator via condensation heat transfer to water in the refueling water tank. The compensating tank is pressurized using a nitrogen gas to make up the water volume change in the PRHRS. Before PRHRS operation, nitrogen may be dissolved in the cooling water of the PRHRS. Therefore, during PRHRS operation, nitrogen gas might be generated due to evaporation in the steam generator, which will act as a noncondensable gas in the condensation heat exchanger. The main objective of the present study was to assess the design of a PRHRS condensation heat exchanger (PRHRS HX) by investigating its heat transfer characteristics

  16. Field tests of 2- and 40-tube condensers at the East Mesa Geothermal Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, R.W.; Domingo, N.

    1982-05-01

    Two water-cooled isobutane condensers, one with 2 tubes and one with 40 tubes, were subjected to field tests at the East Mesa Geothermal Test Site to assess relative heat transfer performance in both surface evaporator and direct-contact evaporator modes. The five groups of tests established that field performance was below earlier laboratory-determined levels and that direct-contact evaporator mode performance was poorer than that for the surface evaporator mode. In all test situations, fluted condenser tubes performed better than smooth condenser tubes. Cooling water quality had no significant effect on performance, but brine preflash in the direct-contact mode did promote some relative performance improvement. Important implications of these results for binary geothermal power plants are that (1) working-fluid-side impurities can significantly degrade heat transfer performance of the power plant condensers and (2) provisions for minimizing such impurities may be required.

  17. 19th Polish Control Conference

    CERN Document Server

    Kacprzyk, Janusz; Oprzędkiewicz, Krzysztof; Skruch, Paweł

    2017-01-01

    This volume contains the proceedings of the KKA 2017 – the 19th Polish Control Conference, organized by the Department of Automatics and Biomedical Engineering, AGH University of Science and Technology in Kraków, Poland on June 18–21, 2017, under the auspices of the Committee on Automatic Control and Robotics of the Polish Academy of Sciences, and the Commission for Engineering Sciences of the Polish Academy of Arts and Sciences. Part 1 deals with general issues of modeling and control, notably flow modeling and control, sliding mode, predictive, dual, etc. control. In turn, Part 2 focuses on optimization, estimation and prediction for control. Part 3 is concerned with autonomous vehicles, while Part 4 addresses applications. Part 5 discusses computer methods in control, and Part 6 examines fractional order calculus in the modeling and control of dynamic systems. Part 7 focuses on modern robotics. Part 8 deals with modeling and identification, while Part 9 deals with problems related to security, fault ...

  18. On the possibility of a ''dry'' cooling tower application for the APS condensators with a dissociating coolant

    International Nuclear Information System (INIS)

    Mikhalevich, A.A.; Nesterenko, V.B.; Peslyak, V.I.

    1975-01-01

    Calculations have been carried out for a Geller cooling tower of a 1000 MW nuclear power plant aimed at investigating the possibility of using ''dry'' cooling towers to cool condensers of nuclear power plants with N 2 O 4 as coolant, and at estimating specific charges on the process water supply system. Taking into consideration commercialy produced equipment, air condenser plants are assumed to operate with an ordinary surface condenser. The main dimensional and cost parameters of a ''dry'' cooling tower for a thermal cycle version with the maximum temperature of 450 deg C are calculated using the Transelectro (Hungary) nomograms for average annual air temperature. The calculation results show the Geller cooling towers for 1000 MW nuclear power plants to be economically competitive with evaporating cooling towers; and more; besides, is this case atmosphere pollution is avoided and water flow rate for making-up the water supply system is reduced

  19. Assessing radioactive concentrates and waste vapor condensate in solidifying radioactive wastes by bituminization

    International Nuclear Information System (INIS)

    Tibensky, L.; Krejci, F.; Breza, M.; Timulak, J.; Hladky, E.

    1986-01-01

    A brief overview is presented of chemical and radiochemical methods used in the world for the analysis of the concentrate of liquid radioactive wastes from nuclear power plants destined for bituminization. Most methods are also suitable for an analysis of the condensate of waste vapors produced in bituminization. The methods of analysis of the radioactive concentrate from the V-1 nuclear power plant in Jaslovske Bohunice and of the waste vapors condensate were developed and tested in practice. Gross gamma activity was measured using a well-type Na(Tl) scintillation detector, the content of radionuclides was determined using semiconductor Ge(Li) spectrometry. The concentration of boric acid in the concentrate was determined by titration with mannite; in the condensate, using spectrophotometry with curcumine. The content of nitrates in both the concentrate and the condensate was determined spectrophotometrically using salicylic acid, the content of nitrites was determined by spectrophotometry using sulfanilic acid and α-naphthylamine. Carbonates and chlorides were determined by titration, sodium and potassium by flame photometry. The content of organic acids was measured by gravimetry of extracted methyl esters, the content of surfactants by spectrophotometry. Infrared spectrophotometry was used in determining hydrocarbons in the waste vapor condensate. The measured value range and the measurement errors are shown for each method. (A.K.)

  20. The development of air cooled condensation systems

    International Nuclear Information System (INIS)

    Bodas, J.

    1990-01-01

    EGI - Contracting/Engineering has had experience with the development of air cooled condensing systems since the 1950's. There are two accepted types of dry cooling systems,the direct and the indirect ones. Due to the fact that the indirect system has several advantages over the direct one, EGI's purpose was to develop an economic, reliable and efficient type of indirect cooling system, both for industrial and power station applications. Apart from system development, the main components of dry cooling plant have been developed as well. These are: the water-to-air heat exchangers; the direct contact (DC, or jet) condenser; the cooling water circulating pumps and recovery turbines; and the peak cooling/preheating units. As a result of this broad development work which was connected with intensive market activity, EGI has supplied about 50% of the dry cooling plants employed for large power stations all over the world. This means that today the cumulated capacity of power units using Heller type dry cooling systems supplied and contracted by EGI is over 6000 MW

  1. An Unbiased View of the History of Polish Medical Physics by a Senior Polish Medical Physicist

    International Nuclear Information System (INIS)

    Chomicki, O. A.

    2008-01-01

    Here is a story told by Maria Sklodowska-Curie at the meeting of the International Committee of Intellectual Cooperation in 1921: 'In a free literary competition on the role and importance of elephants the Englishman's story was 'My adventures while shooting elephants in South Africa', the Frenchman was more concerned with 'The sexual and erotic life of elephants', while the Polish approach was invariably 'The elephant versus Poland's national independence', which seemed quite understandable in the light of over 120 years when Poland was partitioned and lost its independence. Since then this saying has become proverbial and came to express the unmistakably Polish tendency to see everything in terms of Polish interests. In my remarks and reminiscences on the history of the Polish Society of Medical Physics you will quickly recognize the same tendency. First, I will, among other things, try to open some old cupboards to 'produce good [things] from the store of good' (Matthew 12:35), especially concerning the first few years of the activity in medical physics in Poland, and second, I will draw some conclusions and/or offer suggestions based on what a senior medical physicist has seen for more than 50 years of his activity in this field. (author)

  2. Investigation of Condensation Heat Transfer Correlation of Heat Exchanger Design in Secondary Passive Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Ju, Yun Jae; Lee, Hee Joon [Kookmin Univ., Seoul (Korea, Republic of); Kang, Hanok; Lee, Taeho; Park, Cheontae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-12-15

    Recently, condensation heat exchangers have been studied for applications to the passive cooling systems of nuclear plants. To design vertical-type condensation heat exchangers in secondary passive cooling systems, TSCON (Thermal Sizing of CONdenser), a thermal sizing program for a condensation heat exchanger, was developed at KAERI (Korea Atomic Energy Research Institute). In this study, the existing condensation heat transfer correlation of TSCON was evaluated using 1,157 collected experimental data points from the heat exchanger of a secondary passive cooling system for the case of pure steam condensation. The investigation showed that the Shah correlation, published in 2009, provided the most satisfactory results for the heat transfer coefficient with a mean absolute error of 34.8%. It is suggested that the Shah correlation is appropriate for designing a condensation heat exchanger in TSCON.

  3. Cannabinoids cases in polish athletes

    OpenAIRE

    A Pokrywka; Z Obmiński; D Kwiatkowska; R Grucza

    2009-01-01

    The aim of this study was to investigate the number of cases and the profiles of Polish athletes who had occasionally been using marijuana or hashish throughout the period of 1998-2004, with respect to: sex, age, and discipline of sport as well as the period of testing (in- and out-of-competition). Results of the study were compared with some data reported by other WADA accredited anti-doping laboratories. Totally, 13 631 urine samples taken from Polish athletes of both sexes, aged 10-67 year...

  4. Condensation of water vapour on moss-dominated biological soil ...

    Indian Academy of Sciences (India)

    plant growth chamber using an electronic balance recording the weight of condensation. There was ..... Beysens (1995) studied the control of dew for- mation and ..... Subramanian A R and Kesava-Rao A V R 1983 Dew fall in sand dune areas ...

  5. The social shaping of innovation in polish companies

    DEFF Research Database (Denmark)

    Lorentzen, Anne

    2003-01-01

    The paper deals with strategies of innovation in Polish manufacturing companies. The point of departure is a theoretical framework of enterprise level innovation, and of the factors forming strategies of innovation on enterprise level. The paper analyses evidence from 23 Polish companies and pres......The paper deals with strategies of innovation in Polish manufacturing companies. The point of departure is a theoretical framework of enterprise level innovation, and of the factors forming strategies of innovation on enterprise level. The paper analyses evidence from 23 Polish companies...... and presents two cases more in detail. The analysis shows that the Polish companies have all been quite innovative, mostly in relation to product innovation. They choose innovation strategies, which are incremental more than radical, and they tend to differentiate their product range rather than to specialise....... They consider quality development a must in the fight for market shares and they adapt equipment and organisation to this goal. The factors forming and determining the strategies of the companies count the technological knowledge and expertise of the owner/founder, the structural changes of the market...

  6. Semi-strong informational efficiency in the Polish foreign exchange market

    OpenAIRE

    Luksz Goczek

    2015-01-01

    During the financial crisis a notion that the Polish exchange rate is not determined effectively was very dominant, because of a contagion effect of the global financial crisis on the Polish economy. In addition, many foreign exchange market analysts explained developments in the Polish exchange market trough a hypothesis that the Polish zloty exchange rate follows other exchange rates. This contradicts market efficiency as this would lead to profitable arbitrage possibility based on past inf...

  7. Symmetry or asymmetry? Cross-border openness of service providers in Polish-Czech and Polish-German border towns

    Directory of Open Access Journals (Sweden)

    Dołzbłasz Sylwia

    2015-03-01

    Full Text Available The symmetry and/or asymmetry in terms of cross-border openness of service providers is examined in this article, for the cases of two border twin towns: Cieszyn/Český Těšín at the Polish-Czech border, and Gubin/Guben at the Polish-German border. To assess the level of openness of firms towards clients from the other side of the border, four trans-border categories were examined: neighbour’s language visible at store location; business offers in the language of the neighbour; the possibilities of payment in the neighbour’s currency; and the staff’s knowledge of the language. This enabled a comparison of both parts of the particular twin towns in relation to the character of cross-border openness, as well as an assessment of their symmetry/asymmetry. Comparisons of Gubin/Guben and Cieszyn/Český Těšín with respect to the analysed features were also carried out. The analysis shows significant variation in the level of cross-border openness towards clients from neighbouring countries. Whereas in the Polish-Czech town a relative symmetry was observed, in the Polish-German case, significant asymmetry was noted.

  8. Transformation of the Polish Banking Sector

    Directory of Open Access Journals (Sweden)

    Marek Stefański

    2009-07-01

    Full Text Available In the post-war period the banking system in Poland underwent two important system transitions: after 1946 and after 1989. The third transformation began after May 1, 2004, but it did not have a systemic character. The Polish banking sector started to operate on the Single European Market. The first part of the paper is devoted to the problems of the banks transformations after 1989 with a special focus on the quantitative development of banks in 19892008, and on subsequent privatisation and consolidation processes. The former intensified in 19891999, and the latter in 19992002. The consolidation process was very noticeable in the sector of cooperative banks after 1994. The second part of the paper includes an economic and financial analysis of the banks. A lot of attention was paid to the liquidity of the banking sector. It was assessed as good, which was confirmed by a short-term rating of Moodys and by the Financial Stability Report 2009, published by the National Bank of Poland in June 2009. The comparison of the net profit of the banking sector in 19972008 shows its dependence on the economic situation and policy. The number of banks with capital adequacy ratio well above the minimum required by the banking supervision is rising. The financial power ratings are not favorable for the domestic banks. The third part of the paper focuses on the development directions of the Polish banking sector. It may be concluded on the basis of the analysis that privatisation and consolidation processes will be continued. They will concentrate on the capital of foreign banks already operating in Poland. As compared with individual foreign banks, the potential of the Polish banking sector is week. The fourth part of the paper focuses on the presentation Polish banking sector in the context of European Union banking sector. The paper finishes with conclusions. Generally, Polish banks have to implement a strategy to enable them to compete on the Single

  9. Effect of Polishing Systems on Surface Roughness and Topography of Monolithic Zirconia.

    Science.gov (United States)

    Goo, C L; Yap, Auj; Tan, Kbc; Fawzy, A S

    2016-01-01

    This study evaluated the effect of different chairside polishing systems on the surface roughness and topography of monolithic zirconia. Thirty-five monolithic zirconia specimens (Lava PLUS, 3M ESPE) were fabricated and divided into five groups of seven and polished with the following: Group 1 (WZ)-Dura white stone followed by Shofu zirconia polishing kit; Group 2 (SZ)-Shofu zirconia polishing kit; Group 3 (CE)-Ceramiste porcelain polishers; Group 4 (CM)-Ceramaster porcelain polishers; and Group 5 (KZ)-Komet ZR zirconia polishers. All specimens were ground with a fine-grit diamond bur prior to polishing procedures to simulate clinical finishing. Baseline and post-polishing profilometric readings were recorded and delta Ra values (difference in mean surface roughness before and after polishing) were computed and analyzed using one-way analysis of variance and Scheffe post hoc test (pSEM) images of the ground but unpolished and polished specimens were acquired. Delta Ra values ranged from 0.146 for CE to 0.400 for KZ. Delta Ra values for KZ, WZ, and SZ were significantly greater than for CE. Significant differences in delta Ra values were also observed between KZ and CM. The SEM images obtained were consistent with the profilometric findings. Diamond-impregnated polishing systems were more effective than silica carbide-impregnated ones in reducing the surface roughness of ground monolithic zirconia.

  10. Simulation and analysis of an alternative kinematics for improving the polishing uniformity over the surface of polished tiles

    Directory of Open Access Journals (Sweden)

    Weingaertner, W. L.

    2010-10-01

    Full Text Available The present work investigates the possibility of adopting a new kinematics at the industrial polishing lines of porcelain stoneware tile. An alternative motion of the transverse oscillation of the polishing heads is proposed, in which no radical changes in the industries facilities are required. The basic idea is to replace the purely sinus motion of the polishing heads by a rather trapezoid wavelike motion. In theory this could be achieved simply by adopting regular delays at the transverse oscillation motion. Consequences of this alternative kinematics were quantitatively analyzed considering the spatial homogeneity of polishing expected for tiles. Such homogeneity was represented by the coefficient of variation of the distribution of polishing time over the surface, which was in turn determined by means of computational simulations, taking into account the effect of multiple polishing heads.

    El presente trabajo investiga la posibilidad de adoptar una nueva cinemática en las líneas de pulido industrial de baldosas de gres porcelánico. Se propone una propuesta alternativa de la oscilación transversal de los cabezales pulidores, en el que no hay cambios radicales en las instalaciones de las industrias son necesarias. La idea básica consiste en sustituir el movimiento totalmente del seno de los cabezales pulidores por un movimiento ondulatorio trapezoide. En teoría, esto podría lograrse sólo mediante la adopción de los habituales retrasos en el movimiento de oscilación transversal. las consecuencias de esta cinemática fueron analizados cuantitativamente, teniendo en cuenta la homogeneidad espacial de pulido. Tal homogeneidad fora representada por el coeficiente de variación de la distribución de lo tiempo de pulido en la superficie, determinada por medio de simulaciones computacionales, teniendo también en cuenta el efecto de pulido de las cabezas múltiples.

  11. Use of nuclear explosions to create gas condensate storage in the USSR. LLL Treaty Verification Program

    International Nuclear Information System (INIS)

    Borg, I.Y.

    1982-01-01

    The Soviet Union has described industrial use of nuclear explosions to produce underground hydrocarbon storage. To examples are in the giant Orenburg gas condensate field. There is good reason to believe that three additional cavities were created in bedded salt in the yet to be fully developed giant Astrakhan gas condensate field in the region of the lower Volga. Although contrary to usual western practice, the cavities are believed to be used to store H 2 S-rich, unstable gas condensate prior to processing in the main gas plants located tens of kilometers from the producing fields. Detonations at Orenburg and Astrakhan preceded plant construction. The use of nuclear explosions at several sites to create underground storage of highly corrosive liquid hydrocarbons suggests that the Soviets consider this time and cost effective. The possible benefits from such a plan include degasification and stabilization of the condensate before final processing, providing storage of condensate during periods of abnormally high natural gas production or during periods when condensate but not gas processing facilities are undergoing maintenance. Judging from information provided by Soviet specialists, the individual cavities have a maximum capacity on the order of 50,000 m 3

  12. Cannabinoids cases in polish athletes

    Directory of Open Access Journals (Sweden)

    A Pokrywka

    2009-07-01

    Full Text Available The aim of this study was to investigate the number of cases and the profiles of Polish athletes who had occasionally been using marijuana or hashish throughout the period of 1998-2004, with respect to: sex, age, and discipline of sport as well as the period of testing (in- and out-of-competition. Results of the study were compared with some data reported by other WADA accredited anti-doping laboratories. Totally, 13 631 urine samples taken from Polish athletes of both sexes, aged 10-67 years, performing 46 disciplines of sport were tested. Cannabinoids were detected in 267 samples. Among Polish athletes the relative number of positive THC (tetrahydrocannabinol samples was one of the highest in Europe. The group of young Polish athletes (aged 16-24 years was the most THC-positive. THC-positive cases were noted more frequently in male athletes tested during out of competitions. The so-called contact sports (rugby, ice hockey, skating, boxing, badminton, body building and acrobatic sports were those sports, where the higher risk of cannabis use was observed. The legal interpretation of some positive cannabinoids results would be difficult because of some accidental and unintentional use of the narcotics by sportsmen. It was concluded that national anti-doping organizations (NADO’s, which are competent to judge whether the anti-doping rules were violated, should take into account the possibility of non-intentional doping use of cannabinoids via passive smoking of marijuana.

  13. Water Condensation

    DEFF Research Database (Denmark)

    Jensen, Kasper Risgaard; Fojan, Peter; Jensen, Rasmus Lund

    2014-01-01

    The condensation of water is a phenomenon occurring in multiple situations in everyday life, e.g., when fog is formed or when dew forms on the grass or on windows. This means that this phenomenon plays an important role within the different fields of science including meteorology, building physics......, and chemistry. In this review we address condensation models and simulations with the main focus on heterogeneous condensation of water. The condensation process is, at first, described from a thermodynamic viewpoint where the nucleation step is described by the classical nucleation theory. Further, we address...

  14. Investigation of Interfacial Phenomena During Condensation of Humid Air on a Horizontal Substrate

    Directory of Open Access Journals (Sweden)

    Tiwari Akhilesh

    2013-12-01

    Full Text Available The condensation phenomenon of humid air on solid substrates can occur in many applications, and it is known as one of the most difficult problem to deal with for the improvement of the quality of air in a closed environment. The present study was motivated by the investigation of the coupling between ventilation and condensation inside controlled ecological life support systems (CELSS, as it has an important role for higher plants growth in greenhouses and living conditions in manned spacecraft cabins, particularly in long duration space flights or in future space bases. It is well known that the enhancement of the gas exchange with leaves and the growth of plants are dependent on the organoleptic and/or the surrounding thermo-physical factors. Insufficient air movement around plants and condensation on plant leaves generally limit their growth by suppressing the gas diffusion in the leaf boundary-layer thereby decreasing photosynthetic and transpiration rates. Thus, the optimization of a CELSS will require the control of the airflow and concomitant gas/liquid transfer at the plant surfaces. The experimental and theoretical modeling of CELSS requires a comprehensive understanding of the micro to the macro levels of liquid gas phase transfer. Hence, an experimental set-up was developed at 1-g to evaluate the mass transfer coefficients due to condensation of humid air on specific geometries in well controlled environmental conditions. The goal was to establish correlations between the fluxes of mass and heat, the relative humidity and the mean flow for the development of theoretical models based on local transfer coefficients. The experiments were performed at ambient temperature, with a relative humidity between 35-70% and for a velocity range of 1.0-3.0 m.s−1.

  15. Composite adaptive control of belt polishing force for aero-engine blade

    Science.gov (United States)

    Zhsao, Pengbing; Shi, Yaoyao

    2013-09-01

    The existing methods for blade polishing mainly focus on robot polishing and manual grinding. Due to the difficulty in high-precision control of the polishing force, the blade surface precision is very low in robot polishing, in particular, quality of the inlet and exhaust edges can not satisfy the processing requirements. Manual grinding has low efficiency, high labor intensity and unstable processing quality, moreover, the polished surface is vulnerable to burn, and the surface precision and integrity are difficult to ensure. In order to further improve the profile accuracy and surface quality, a pneumatic flexible polishing force-exerting mechanism is designed and a dual-mode switching composite adaptive control(DSCAC) strategy is proposed, which combines Bang-Bang control and model reference adaptive control based on fuzzy neural network(MRACFNN) together. By the mode decision-making mechanism, Bang-Bang control is used to track the control command signal quickly when the actual polishing force is far away from the target value, and MRACFNN is utilized in smaller error ranges to improve the system robustness and control precision. Based on the mathematical model of the force-exerting mechanism, simulation analysis is implemented on DSCAC. Simulation results show that the output polishing force can better track the given signal. Finally, the blade polishing experiments are carried out on the designed polishing equipment. Experimental results show that DSCAC can effectively mitigate the influence of gas compressibility, valve dead-time effect, valve nonlinear flow, cylinder friction, measurement noise and other interference on the control precision of polishing force, which has high control precision, strong robustness, strong anti-interference ability and other advantages compared with MRACFNN. The proposed research achieves high-precision control of the polishing force, effectively improves the blade machining precision and surface consistency, and

  16. The use of titanium for condenser tube bundles

    International Nuclear Information System (INIS)

    Dobrovitch, N.

    2002-01-01

    In a power plant, the condenser is a strategic heat exchanger with regards to the efficiency of the steam turbine and its reliability guarantees the performance and continuous operation of the plant. Until the early 1980's, copper alloys were routinely used in condenser tubes, thanks to their high heat transfer rates. Yet numerous problems arose from the use of this material, such as stress cracking corrosion, ammoniacal corrosion, fouling, erosion, dezincification, abrasion, erosion-corrosion,... and lately the problem of inadequateness of copper with nuclear steam generators (in nuclear power plant the abrasion problem of the copper alloy tubes created a deposit problem in the steam generator conducting to the replacement of all the condensers). The trend was then to consider new tube materials, such stainless steel and titanium, firstly for particular operating conditions and now for most of the projects, with several objectives, such as: 1) improve the reliability (titanium in particular can bring major improvements such as higher water velocities promoting better heat coefficients, excellent resistance to abrasion, erosion and corrosion thereby improving resistance to fouling; 2) find more cost-effective solutions. The first investment is higher but money is saved on maintenance costs and on time reliability of the material. Titanium tube manufacturing has greatly evolved for the last 20 years. Tubes are mostly welded tubes from ASTM SB 338 grade 1 made on a continuous manufacturing line. All manufacturing operations (welding, annealing, non-destructive testing) are fully automated to produce high quality tubes in large quantities. The most common way to attach tubes to a tubesheet is to roller expand them. (A.C.)

  17. Monitoring of Robot Assisted Polishing through parameters of acoustic emission

    DEFF Research Database (Denmark)

    Lazarev, Ruslan; Top, Søren; Bilberg, Arne

    The polishing process is essential for the surface generation of machine tooling components in advanced manufacturing. While robot assisted polishing is faster and more consistent than manual polishing, it can still consume a significant part of ma- chining time and operator presence time...

  18. Deuterium concentration deterioration in feed synthesis gas from ammonia plant to heavy water plant (Preprint No. ED-5)

    International Nuclear Information System (INIS)

    Sah, A.K.

    1989-04-01

    Heavy Water Plant (Thal) is designed for 110 T/ Year capacity (55 T/Year each stream), with inlet deuterium concentration of feed synthesis gas at 115 ppm and depleted to 15 ppm. During first start up of plant the inlet concentration to feed synthesis gas was about 97 ppm. At that time the rich condensate recirculation was not there. To make the effective recirculation of deuterium rich condensate and minimum posssible losses some modifications were carried out in ammonia plant. Major ones are: (i)Demineralised (DM) water export for heavy water plant and urea plant which was having deuterium rich DM water connection was connected with DM water of urea plant which is not rich in deuterium, (ii)Sample cooler pump suction was connected with raw water, (iii)Ammonia plant line No.II condensate stripper was rectified during annual shut down to avoid excessive steam venting from its top and other draining, and (iv)Stripper condensate directly connected to make up water bypassing open settler to avoid evaporation and diffusion losses. With these modifications the deuterium concentration in feed synthesis gas improved to about 105 ppm. To improve it to 115 ppm, further modifications are suggested. (author). 5 figs

  19. Transformation of Litchi Pericarp-Derived Condensed Tannin with Aspergillus awamori

    Directory of Open Access Journals (Sweden)

    Sen Lin

    2016-07-01

    Full Text Available Condensed tannin is a ubiquitous polyphenol in plants that possesses substantial antioxidant capacity. In this study, we have investigated the polyphenol extraction recovery and 2,2-diphenyl-1-picrylhydrazyl (DPPH scavenging activity of the extracted polyphenol after litchi pericarp is treated with Aspergillus awamori, Aspergillus sojae or Aspergillus oryzae. We have further explored the activity of A. awamori in the formation of condensed tannin. The treatment of A. awamori appeared to produce the highest antioxidant activity of polyphenol from litchi pericarp. Further studies suggested that the treatment of A. awamori releases the non-extractable condensed tannin from cell walls of litchi pericarp. The total extractable tannin in the litchi pericarp residue after a six-time extraction with 60% ethanol increased from 199.92 ± 14.47–318.38 ± 7.59 μg/g dry weight (DW after the treatment of A. awamori. The ESI-TOF-MS and HPLC-MS2 analyses further revealed that treatment of A. awamori degraded B-type condensed tannin (condensed flavan-3-ol via C4–C8 linkage, but exhibited a limited capacity to degrade the condensed tannin containing A-type linkage subunits (C4–C8 coupled C2–O–C7 linkage. These results suggest that the treatment of A. awamori can significantly improve the production of condensed tannin from litchi pericarp.

  20. Trace element analysis of nail polishes

    International Nuclear Information System (INIS)

    Misra, G.; Mittal, V.K.; Sahota, H.S.

    1999-01-01

    Instrumental neutron activation analysis (INAA) technique was used to measure the concentrations of various trace elements in nail polishes of popular Indian and foreign brands. The aim of the present experiment was to see whether trace elements could distinguish nail polishes of different Indian and foreign brands from forensic point of view. It was found that cesium can act as a marker to differentiate foreign and Indian brands. (author)

  1. Factors influencing the surface quality of polished tool steels

    International Nuclear Information System (INIS)

    Rebeggiani, S; Rosén, B-G

    2014-01-01

    Today’s demands on surface quality of moulds for injection moulding of plastic components involve no/low defect contents and roughness levels in the nm-range for high gloss applications. Material properties as well as operating conditions influence the mould finish, and thus the final surface of moulded products. This paper focuses on how particle content and different polishing strategies influence final surface qualities of moulds. Visual estimations of polished tool steel samples were combined with non-contact 3D-surface texture analysis in order to correlate traditional assessments to more quantitative methods, and to be able to analyse the surfaces at nanometre-level. It was found that steels with a lower proportion of particles, like carbides and oxides, gave rise to smoother polished surfaces. In a comparative study of polishers from different polishing shops, it was found that while different surface preparation strategies can lead to similar final roughness, similar preparation techniques can produce high-quality surfaces from different steel grades. However, the non-contact 3D-surface texture analysis showed that not all smooth polished surfaces have desirable functional topographies for injection moulding of glossy plastic components. (paper)

  2. New perspectives in hydrodynamic radial polishing techniques for optical surfaces

    Science.gov (United States)

    Ruiz, Elfego; Sohn, Erika; Luna, Esteban; Salas, Luis; Cordero, Alberto; González, Jorge; Núñez, Manuel; Salinas, Javier; Cruz-González, Irene; Valdés, Jorge; Cabrera, Victor; Martínez, Benjamín

    2004-09-01

    In order to overcome classic polishing techniques, a novel hydrodynamic radial polishing tool (HyDRa) is presented; it is useful for the corrective lapping and fine polishing of diverse materials by means of a low-cost abrasive flux and a hydrostatic suspension system that avoids contact of the tool with the working surface. This tool enables the work on flat or curved surfaces of currently up to two and a half meters in diameter. It has the advantage of avoiding fallen edges during the polishing process as well as reducing tool wear out and deformation. The functioning principle is based on the generation of a high-velocity, high-pressure, abrasive emulsion flux with radial geometry. The polishing process is repeatable by means of the control of the tool operational parameters, achieving high degrees of precision and accuracy on optical and semiconductor surfaces, with removal rates of up to 9 mm3/hour and promising excellent surface polishing qualities. An additional advantage of this new tool is the possibility to perform interferometric measurements during the polishing process without the need of dismounting the working surface. A series of advantages of this method, numerical simulations and experimental results are described.

  3. Municipal Waste-to-Energy plants in Poland – current projects

    Directory of Open Access Journals (Sweden)

    Cyranka Maciej

    2016-01-01

    Conclusions show why in the current situation development of Polish WtE infrastructure is right, i.e. operation of aforementioned plants that will ensure benefits associated with energy production, reduction of landfilling and informing public opinion regarding modern waste management models. Additionally, the article draws attention on the high responsibility that will be put on WtE plants operators and that experience gained during WtE implementation can be used to improve even further for future Polish Waste Management Systems.

  4. Conceptual Design of Condenser using PCM as PCCS for APR1400

    International Nuclear Information System (INIS)

    Jung, Hwa-Young; Ko, A-Reum; Lee, Jeong Ik; Yoon, Ho Joon

    2016-01-01

    In this study, the conceptual design of the condenser using the phase change material (PCM) is proposed as another PCCS concept for PWRs. It is possible to install the condenser for the existing nuclear power plants under operation without PCCS. Most of all, this condenser has to be designed to reduce the pressure and temperature in the containment until the containment spray system is available. A feature of the condenser as shown in Fig. 2 is the composition of PCM and wire mesh connected with the fins to improve heat transfer. As the first step, a preliminary study was conducted to find the optimum design of the part at which the condensation occurs under the given conditions. The results show that the fin base area as well as the total heat transfer area of fins are generally in inversely proportional to the average condensation heat transfer coefficient. Also, the point at which the gradient is changed is when the flow regime is changed from wavy flow to turbulent flow. However, the number of fins shows the different trend. Thus, in order to achieve better average condensation heat transfer coefficient under the identical heat capacity condition, the shorter the fin length and the more fins are necessary for the optimum design the condenser in wavy flow region

  5. Conceptual Design of Condenser using PCM as PCCS for APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hwa-Young; Ko, A-Reum; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of); Yoon, Ho Joon [KUSTAR, Abu Dhabi (United Arab Emirates)

    2016-10-15

    In this study, the conceptual design of the condenser using the phase change material (PCM) is proposed as another PCCS concept for PWRs. It is possible to install the condenser for the existing nuclear power plants under operation without PCCS. Most of all, this condenser has to be designed to reduce the pressure and temperature in the containment until the containment spray system is available. A feature of the condenser as shown in Fig. 2 is the composition of PCM and wire mesh connected with the fins to improve heat transfer. As the first step, a preliminary study was conducted to find the optimum design of the part at which the condensation occurs under the given conditions. The results show that the fin base area as well as the total heat transfer area of fins are generally in inversely proportional to the average condensation heat transfer coefficient. Also, the point at which the gradient is changed is when the flow regime is changed from wavy flow to turbulent flow. However, the number of fins shows the different trend. Thus, in order to achieve better average condensation heat transfer coefficient under the identical heat capacity condition, the shorter the fin length and the more fins are necessary for the optimum design the condenser in wavy flow region.

  6. Investment in new power generation under uncertainty: Benefits of CHP vs. condensing plants in a copula-based analysis

    International Nuclear Information System (INIS)

    Westner, Günther; Madlener, Reinhard

    2012-01-01

    In this paper, we apply a spread-based real options approach to analyze the decision-making problem of an investor who has the choice between an irreversible investment in a condensing power plant without heat utilization and a plant with combined heat-and-power (CHP) generation. Our investigation focuses on large-scale fossil-fueled generation technologies and is based on a stochastic model that uses copula functions to provide the input parameters of the real options model. We define the aggregated annual spread as assessment criteria for our investigation since it contains all relevant volatile input parameters that have an impact on the evaluation of investment decisions. We show that the specific characteristics of CHP plants, such as additional revenues from heat sales, promotion schemes, specific operational features, and a beneficial allocation of CO 2 allowances, have a significant impact on the option value and therefore on the optimal timing for investment. For the two fossil-fueled CHP technologies investigated (combined-cycle gas turbine and steam turbine), we conclude from our analysis that a high share of CHP generation reduces the risk exposure for the investor. The maximal possible CHP generation depends significantly on the local heat demand in the surroundings of the power plant. Considering this, the size of the heat sink available could gain more relevance in the future selection process of sites for new large-scale fossil power plants.

  7. Evaluation of Advanced Models for PAFS Condensation Heat Transfer in SPACE Code

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Byoung-Uhn; Kim, Seok; Park, Yu-Sun; Kang, Kyung Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ahn, Tae-Hwan; Yun, Byong-Jo [Pusan National University, Busan (Korea, Republic of)

    2015-10-15

    The PAFS (Passive Auxiliary Feedwater System) is operated by the natural circulation to remove the core decay heat through the PCHX (Passive Condensation Heat Exchanger) which is composed of the nearly horizontal tubes. For validation of the cooling and operational performance of the PAFS, PASCAL (PAFS Condensing Heat Removal Assessment Loop) facility was constructed and the condensation heat transfer and natural convection phenomena in the PAFS was experimentally investigated at KAERI (Korea Atomic Energy Research Institute). From the PASCAL experimental result, it was found that conventional system analysis code underestimated the condensation heat transfer. In this study, advanced condensation heat transfer models which can treat the heat transfer mechanisms with the different flow regimes in the nearly horizontal heat exchanger tube were analyzed. The models were implemented in a thermal hydraulic safety analysis code, SPACE (Safety and Performance Analysis Code for Nuclear Power Plant), and it was evaluated with the PASCAL experimental data. With an aim of enhancing the prediction capability for the condensation phenomenon inside the PCHX tube of the PAFS, advanced models for the condensation heat transfer were implemented into the wall condensation model of the SPACE code, so that the PASCAL experimental result was utilized to validate the condensation models. Calculation results showed that the improved model for the condensation heat transfer coefficient enhanced the prediction capability of the SPACE code. This result confirms that the mechanistic modeling for the film condensation in the steam phase and the convection in the condensate liquid contributed to enhance the prediction capability of the wall condensation model of the SPACE code and reduce conservatism in prediction of condensation heat transfer.

  8. Life cycle assessment study on polishing units for use of treated wastewater in agricultural reuse.

    Science.gov (United States)

    Büyükkamacı, Nurdan; Karaca, Gökçe

    2017-12-01

    A life cycle assessment (LCA) approach was used in the assessment of environmental impacts of some polishing units for reuse of wastewater treatment plant effluents in agricultural irrigation. These alternative polishing units were assessed: (1) microfiltration and ultraviolet (UV) disinfection, (2) cartridge filter and ultrafiltration (UF), and (3) just UV disinfection. Two different energy sources, electric grid mix and natural gas, were considered to assess the environmental impacts of them. Afterwards, the effluent of each case was evaluated against the criteria required for irrigation of sensitive crops corresponding to Turkey regulations. Evaluation of environmental impacts was carried out with GaBi 6.1 LCA software. The overall conclusion of this study is that higher electricity consumption causes higher environmental effects. The results of the study revealed that cartridge filter and UF in combination with electric grid mix has the largest impact on the environment for almost all impact categories. In general, the most environmentally friendly solution is UV disinfection. The study revealed environmental impacts for three alternatives drawing attention to the importance of the choice of the most appropriate polishing processes and energy sources for reuse applications.

  9. Damage-free polishing of monocrystalline silicon wafers without chemical additives

    International Nuclear Information System (INIS)

    Biddut, A.Q.; Zhang, L.C.; Ali, Y.M.; Liu, Z.

    2008-01-01

    This investigation explores the possibility and identifies the mechanism of damage-free polishing of monocrystalline silicon without chemical additives. Using high resolution electron microscopy and contact mechanics, the study concludes that a damage-free polishing process without chemicals is feasible. All forms of damages, such as amorphous Si, dislocations and plane shifting, can be eliminated by avoiding the initiation of the β-tin phase of silicon during polishing. When using 50 nm abrasives, the nominal pressure to achieve damage-free polishing is 20 kPa

  10. Survival of juvenile fishes receiving thermal and mechanical stresses in a simulated power plant condenser

    International Nuclear Information System (INIS)

    Kedl, R.J.; Coutant, C.C.

    Experiments were conducted in a water-recirculating loop to determine the effects of fluid-induced stresses (e.g., turbulence, pressure, and vacuum) on six species of larval fish and one species each of frog tadpoles and zooplankton. These stresses simulate the insults developed in the condenser portion, but not including the pump, of a steam power plant. Some experiments were conducted with thermal stresses superimposed on fluid-induced stresses. Fluid-induced stresses of the magnitude developed in these experiments were generally not fatal to the larval fish within the precision of the experiments, although some sublethal effects were noted. When thermal stress was superimposed on the fluid-induced stresses, the mortalities were equivalent to those resulting from thermal stress alone. Fluid-induced stresses of low magnitude were not fatal to Daphnia magna, but fluid-induced stresses of higher magnitude were responsible for significant mortalities. (U.S.)

  11. Computer-Controlled Cylindrical Polishing Process for Large X-Ray Mirror Mandrels

    Science.gov (United States)

    Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    We are developing high-energy grazing incidence shell optics for hard-x-ray telescopes. The resolution of a mirror shells depends on the quality of cylindrical mandrel from which they are being replicated. Mid-spatial-frequency axial figure error is a dominant contributor in the error budget of the mandrel. This paper presents our efforts to develop a deterministic cylindrical polishing process in order to keep the mid-spatial-frequency axial figure errors to a minimum. Simulation software is developed to model the residual surface figure errors of a mandrel due to the polishing process parameters and the tools used, as well as to compute the optical performance of the optics. The study carried out using the developed software was focused on establishing a relationship between the polishing process parameters and the mid-spatial-frequency error generation. The process parameters modeled are the speeds of the lap and the mandrel, the tool s influence function, the contour path (dwell) of the tools, their shape and the distribution of the tools on the polishing lap. Using the inputs from the mathematical model, a mandrel having conical approximated Wolter-1 geometry, has been polished on a newly developed computer-controlled cylindrical polishing machine. The preliminary results of a series of polishing experiments demonstrate a qualitative agreement with the developed model. We report our first experimental results and discuss plans for further improvements in the polishing process. The ability to simulate the polishing process is critical to optimize the polishing process, improve the mandrel quality and significantly reduce the cost of mandrel production

  12. Dynamic Modeling of Steam Condenser and Design of PI Controller Based on Grey Wolf Optimizer

    OpenAIRE

    Shu-Xia Li; Jie-Sheng Wang

    2015-01-01

    Shell-and-tube condenser is a heat exchanger for cooling steam with high temperature and pressure, which is one of the main kinds of heat exchange equipment in thermal, nuclear, and marine power plant. Based on the lumped parameter modeling method, the dynamic mathematical model of the simplified steam condenser is established. Then, the pressure PI control system of steam condenser based on the Matlab/Simulink simulation platform is designed. In order to obtain better performance, a new meta...

  13. Numerical study of the thermo-flow performances of novel finned tubes for air-cooled condensers in power plant

    Science.gov (United States)

    Guo, Yonghong; Du, Xiaoze; Yang, Lijun

    2018-02-01

    Air-cooled condenser is the main equipment of the direct dry cooling system in a power plant, which rejects heat of the exhaust steam with the finned tube bundles. Therefore, the thermo-flow performances of the finned tubes have an important effect on the optimal operation of the direct dry cooling system. In this paper, the flow and heat transfer characteristics of the single row finned tubes with the conventional flat fins and novel jagged fins are investigated by numerical method. The flow and temperature fields of cooling air for the finned tubes are obtained. Moreover, the variations of the flow resistance and average convection heat transfer coefficient under different frontal velocity of air and jag number are presented. Finally, the correlating equations of the friction factor and Nusselt number versus the Reynolds number are fitted. The results show that with increasing the frontal velocity of air, the heat transfer performances of the finned tubes are enhanced but the pressure drop will increase accordingly, resulting in the average convection heat transfer coefficient and friction factor increasing. Meanwhile, with increasing the number of fin jag, the heat transfer performance is intensified. The present studies provide a reference in optimal designing for the air-cooled condenser of direct air cooling system.

  14. Near-term feasibility of nuclear reactors for seawater desalting. Coupling of standard condensing nuclear power stations to low-grade heat multieffect distillation plants

    International Nuclear Information System (INIS)

    Adar, J.; Manor, S.; Schaal, M.

    1977-01-01

    The paper describes the horizontal aluminium tube, multieffect distillation process developed by Israel Desalination Engineering Ltd., which is very suitable for the use of low-grade heat from standard condensing nuclear turbines operating at increased back-pressure. A special flash-chamber constitutes a positive barrier against any possible contamination being carried over by the steam exhausted from the turbine to the desalination plant. Flow sheets, heat and mass balances have been prepared for two standard sizes of NSSS and turbines, two back-pressures, and corresponding desalination plants. Only standard equipment is being used in the steam and electricity-producing plant. The desalination plant consists of 6 to 12 parallel double lines, each of them similar to a large prototype now being designed and which will be coupled to an old fossil-fuel power station. Total energy requirements of the desalination plant represent only 19 to 50% of the total water cost as against 75% for a single-purpose plant. Costs are based on actual bids for the power plant and actual estimates for the desalination prototype. The operation is designed to be flexible so that the power plant can be operated either in conjunction with the desalination plant, or as a single-purpose plant. (author)

  15. Investigation of impingement attack mechanism of copper alloy condenser tubes

    Energy Technology Data Exchange (ETDEWEB)

    Fukumura, Takuya; Nakajima, Nobuo; Arioka, Koji; Totsuka, Nobuo; Nakagawa, Tomokazu [Institute of Nuclear Safety System Inc., Mihama, Fukui (Japan)

    2001-09-01

    In order to investigate generation and growth mechanisms of impingement attacks of sea water against copper alloy condenser tubes used in condensers of nuclear power plants, we took out condenser tubes from actual condensers, cut them into several pieces and carried out several material tests mainly for impinged spots. In addition water flow inside of a pit was analyzed. From the results of the investigation, it was found that all of impingement attacks were found in the marks left by sessile organisms and none were found in downstream of the marks as frequently proposed so far. At the pits generated inside the marks, iron coating was striped and zinc content was deficient in some cases. Combining these data and the result of flow analysis, we considered the following mechanism of the impingement attacks: sessile organisms clinging to the surface of the condenser tube and growth, occlusion of the tube, extinction and decomposition of sessile organisms, pollution corrosion under the organisms and cavity formation, occlusion removal by the cleaning, generation of impingement attacks by flow collision inside the cavity, growth of the impingement attacks. (author)

  16. Strain-free polished channel-cut crystal monochromators: a new approach and results

    Science.gov (United States)

    Kasman, Elina; Montgomery, Jonathan; Huang, XianRong; Lerch, Jason; Assoufid, Lahsen

    2017-08-01

    The use of channel-cut crystal monochromators has been traditionally limited to applications that can tolerate the rough surface quality from wet etching without polishing. We have previously presented and discussed the motivation for producing channel cut crystals with strain-free polished surfaces [1]. Afterwards, we have undertaken an effort to design and implement an automated machine for polishing channel-cut crystals. The initial effort led to inefficient results. Since then, we conceptualized, designed, and implemented a new version of the channel-cut polishing machine, now called C-CHiRP (Channel-Cut High Resolution Polisher), also known as CCPM V2.0. The new machine design no longer utilizes Figure-8 motion that mimics manual polishing. Instead, the polishing is achieved by a combination of rotary and linear functions of two coordinated motion systems. Here we present the new design of C-CHiRP, its capabilities and features. Multiple channel-cut crystals polished using the C-CHiRP have been deployed into several beamlines at the Advanced Photon Source (APS). We present the measurements of surface finish, flatness, as well as topography results obtained at 1-BM of APS, as compared with results typically achieved when polishing flat-surface monochromator crystals using conventional polishing processes. Limitations of the current machine design, capabilities and considerations for strain-free polishing of highly complex crystals are also discussed, together with an outlook for future developments and improvements.

  17. Concentrations of major and trace elements in polished rice and paddy soils collected in Aomori, Japan

    International Nuclear Information System (INIS)

    Tsukada, H.; Hasegawa, H.; Takeda, A.; Hisamatsu, S.

    2005-01-01

    Rice is a staple food in most Asian countries including Japan, and it is important to evaluate the intake of elements through polished rice ingestion in daily life. Rice grain samples and surface paddy soil samples were collected from 20 sites throughout Aomori Prefecture, Japan. Rice grains were threshed and then polished to 90% of the total weight of brown rice. The polished rice samples for the determination of the neutron activation analysis (NAA) were dried at 50 degree C and those of the inductively coupled plasma-mass spectrometer (ICP-MS) were ashed at a temperature below 450 degree C to avoid loss of alkali metals. The soil samples were dried at 50 degree C and were pulverized with an agate ball mill. The concentrations of As, Cl and I in the polished rice and As, Cl, I, Ti and Zr in the soils were determined by the NAA. The concentrations of 22 elements in the polished rice and 28 elements in the soils were determined by the ICP-MS. The mean concentrations of essential elements in the polished rice such as K, Mg, Cl, Ca, Zn, Mn, Fe, Cu and Mo were 720, 270, 160, 54, 16, 9.7, 2.3, 21 and 0.47 mg kg -1 dry weight, respectively, and the range of each element was within one order of magnitude. However, the ranges of most trace elements in the polished rice including Al, Ni, Ba, Cd, Pb, Cr, I, Ag and Cs were more than one order of magnitude. The mean concentrations of non-essential elements in the polished rice were as follows: Na, 11; Al, 3.9; Rb, 1.2; Ni, 0.11; As, Sr, Ba, Cd, V and Pb, 0.1-0.01; Cr, I, Co, Ag, Se and Cs, O.Ol-0.001 mg kg -1 dry weight. The concentration ranges of elements, except for I, in the paddy soils were within one order of magnitude. The mean concentrations of elements in the soils were as follows: Al, Fe, Ca and Na, 100000-10000; Mg, K and Ti, 10000-1000; Mn, Ba, Cl, Zr, Sr and Zn, 1000-100; V, Ce, Cr, Rb, Cu, Pb, Sc, La, As and Ni, 100-10; Co, Th, Cs, I, U, Mo and Se, 10-1; Sb, Cd and Ag, 1-0.1 mg kg -1 . The mean concentrations of

  18. Performance of evaporative condensers

    Energy Technology Data Exchange (ETDEWEB)

    Ettouney, Hisham M.; El-Dessouky, Hisham T.; Bouhamra, Walid; Al-Azmi, Bader

    2001-07-01

    Experimental investigation is conducted to study the performance of evaporative condensers/coolers. The analysis includes development of correlations for the external heat transfer coefficient and the system efficiency. The evaporative condenser includes two finned-tube heat exchangers. The system is designed to allow for operation of a single condenser, two condensers in parallel, and two condensers in series. The analysis is performed as a function of the water-to-air mass flow rate ratio (L/G) and the steam temperature. Also, comparison is made between the performance of the evaporative condenser and same device as an air-cooled condenser. Analysis of the collected data shows that the system efficiency increases at lower L/G ratios and higher steam temperatures. The system efficiency for various configurations for the evaporative condenser varies between 97% and 99%. Lower efficiencies are obtained for the air-cooled condenser, with values between 88% and 92%. The highest efficiency is found for the two condensers in series, followed by two condensers in parallel and then the single condenser. The parallel condenser configuration can handle a larger amount of inlet steam and can provide the required system efficiency and degree of subcooling. The correlation for the system efficiency gives a simple tool for preliminary system design. The correlation developed for the external heat transfer coefficient is found to be consistent with the available literature data. (Author)

  19. Can Reduced-Step Polishers Be as Effective as Multiple-Step Polishers in Enhancing Surface Smoothness?

    Science.gov (United States)

    Kemaloglu, Hande; Karacolak, Gamze; Turkun, L Sebnem

    2017-02-01

    The aim of this study was to evaluate the effects of various finishing and polishing systems on the final surface roughness of a resin composite. Hypotheses tested were: (1) reduced-step polishing systems are as effective as multiple-step systems on reducing the surface roughness of a resin composite and (2) the number of application steps in an F/P system has no effect on reducing surface roughness. Ninety discs of a nano-hybrid resin composite were fabricated and divided into nine groups (n = 10). Except the control, all of the specimens were roughened prior to be polished by: Enamel Plus Shiny, Venus Supra, One-gloss, Sof-Lex Wheels, Super-Snap, Enhance/PoGo, Clearfil Twist Dia, and rubber cups. The surface roughness was measured and the surfaces were examined under scanning electron microscope. Results were analyzed with analysis of variance and Holm-Sidak's multiple comparisons test (p One-gloss, Enamel Plus Shiny, and Venus Supra groups. (1) The number of application steps has no effect on the performance of F/P systems. (2) Reduced-step polishers used after a finisher can be preferable to multiple-step systems when used on nanohybrid resin composites. (3) The effect of F/P systems on surface roughness seems to be material-dependent rather than instrument- or system-dependent. Reduced-step systems used after a prepolisher can be an acceptable alternative to multiple-step systems on enhancing the surface smoothness of a nanohybrid composite; however, their effectiveness depends on the materials' properties. (J Esthet Restor Dent 29:31-40, 2017). © 2016 Wiley Periodicals, Inc.

  20. Ethanolamine properties and use for feedwater pH control: A pressurized water reactor case study

    International Nuclear Information System (INIS)

    Keeling, D.L.; Polidoroff, C.T.; Cortese, S.; Cushner, M.C.

    1995-01-01

    Ethanolamine (ETA) as a feedwater pH control additive has been recently used to minimize corrosion of secondary water components in the nuclear power industry pressurized water reactors (PWRs). The use of ETA is compared with ammonia. Relative volatility effects on various parts of the system are analyzed and chemistry changes are presented. Materials of construction and the use of existing plant equipment for ETA service are discussed. Properties of ETA as well as safety, storage and handling issues are compared with ammonia. Health d aquatic toxicity are reviewed. warnings, safety, handling guidelines, biodegradability an Diablo Canyon Power Plant used ammonia for pH control from 1985 until a change over to ETA in 1993/1994. Full flow condensate polishers that are required to protect the plant from saltwater cooling incursions limit the amount of pH additive. Iron levels in the secondary water systems are compared before and after changing to ETA and replacement of corrosion-susceptible piping. Iron reduction benefits are assessed along with other effects on the feedwater nozzles, low pressure turbine, polisher resin capacity and polisher regeneration system

  1. Ideal climatic conditions for condensation of atmospheric moisture on the plants’ surface

    Directory of Open Access Journals (Sweden)

    Prokhorov Alexey

    2015-12-01

    A study of the diversity of the plant adaptation mechanisms that contribute to lowering the surface temperature and the absorption of condensate will allow us in the future to carry out introduction, genetic modification or selection of plants with the most visible effect of lowering the temperature and the least dependence on insolation.

  2. Surface geometry of three packable and one hybrid composite after polishing.

    Science.gov (United States)

    Jung, Martin; Bruegger, Hilka; Klimek, Joachim

    2003-01-01

    This study evaluated the surface quality of four composite materials after polishing with six different polishing techniques. Eighty specimens were made using three packable composites (Definite/Degussa, SureFil/ Dentsply and Solitaire/Heraeus-Kulzer) and one hybrid composite (Herculite XRV/Kerr). Five specimens of each material were polished using flexible Sof-Lex discs. The remaining 75 specimens of each composite were prepared using three finishing protocols: a single 30 microm diamond (n = 25), two finishing diamonds (30/20 microm; n = 25) and a 30 microm diamond followed by a tungsten carbide finishing bur (n = 25). Final polishing of each of the three finishing groups was accomplished with SuperBuff, Diafix-oral, OneGloss, Astropol and HaWe Composite Polishers (n = 5, each). Surface roughness was evaluated quantitatively by laser-stylus profilometry. Average roughness (R(a)) was calculated; statistical analysis of the data was performed with two-way ANOVA and Scheffé post-hoc tests. The polished surfaces were examined qualitatively by SEM. The results showed significant effects on surface roughness from the different composites (p = 0.011) and polishing systems (p < 0.001). After polishing, the Solitaire surfaces (R(a) = 0.72 microm) were smoother than Definite (R(a) = 0.87 microm) and SureFil (R(a) = 0.89 microm) and significantly smoother than Herculite (R(a) = 0.92 microm; p = 0.011). Three of the polishing methods (SuperBuff, Diafix-oral and Astropol) achieved lower R(a)-values than Sof-Lex discs. The polishing quality of the one-step systems SuperBuff and Diafix-oral was strongly affected by the initial finishing protocol.

  3. Study of Profile Changes during Mechanical Polishing using Relocation Profilometry

    Science.gov (United States)

    Kumaran, S. Chidambara; Shunmugam, M. S.

    2017-10-01

    Mechanical polishing is a finishing process practiced conventionally to enhance quality of surface. Surface finish is improved by mechanical cutting action of abrasive particles on work surface. Polishing is complex in nature and research efforts have been focused on understanding the polishing mechanism. Study of changes in profile is a useful method of understanding behavior of the polishing process. Such a study requires tracing same profile at regular process intervals, which is a tedious job. An innovative relocation technique is followed in the present work to study profile changes during mechanical polishing of austenitic stainless steel specimen. Using special locating fixture, micro-indentation mark and cross-correlation technique, the same profile is traced at certain process intervals. Comparison of different parameters of profiles shows the manner in which metal removal takes place in the polishing process. Mass removal during process estimated by the same relocation technique is checked with that obtained using weight measurement. The proposed approach can be extended to other micro/nano finishing processes and favorable process conditions can be identified.

  4. Development of hybrid fluid jet/float polishing process

    Science.gov (United States)

    Beaucamp, Anthony T. H.; Namba, Yoshiharu; Freeman, Richard R.

    2013-09-01

    On one hand, the "float polishing" process consists of a tin lap having many concentric grooves, cut from a flat by single point diamond turning. This lap is rotated above a hydrostatic bearing spindle of high rigidity, damping and rotational accuracy. The optical surface thus floats above a thin layer of abrasive particles. But whilst surface texture can be smoothed to ~0.1nm rms (as measured by atomic force microscopy), this process can only be used on flat surfaces. On the other hand, the CNC "fluid jet polishing" process consists of pumping a mixture of water and abrasive particles to a converging nozzle, thus generating a polishing spot that can be moved along a tool path with tight track spacing. But whilst tool path feed can be moderated to ultra-precisely correct form error on freeform optical surfaces, surface finish improvement is generally limited to ~1.5nm rms (with fine abrasives). This paper reports on the development of a novel finishing method, that combines the advantages of "fluid jet polishing" (i.e. freeform corrective capability) with "float polishing" (i.e. super-smooth surface finish of 0.1nm rms or less). To come up with this new "hybrid" method, computational fluid dynamic modeling of both processes in COMSOL is being used to characterize abrasion conditions and adapt the process parameters of experimental fluid jet polishing equipment, including: (1) geometrical shape of nozzle, (2) position relative to the surface, (3) control of inlet pressure. This new process is aimed at finishing of next generation X-Ray / Gamma Ray focusing optics.

  5. Condition monitoring and life assessment of lake water cooled admiralty brass condenser tubes of a nuclear power plant

    International Nuclear Information System (INIS)

    De, P.K.; Ghosal, S.K.; Kutty, K.K.; Bhat, H.R.

    2000-01-01

    The present paper deals with the failure of condenser tubes in a nuclear power plant. The tubes were made of arsenical admiralty brass and were cooled using lake water. They were in service for over 25 years. So far about 1000 tubes have been plugged as they failed due to several reasons. In order to assess the remaining life of the existing tubes as well as to investigate the cause of recent tube failures, some of the tubes from the condenser were removed and examined in detail following several procedure. It was observed that in general, wall thickness of the tubes was reduced by 10- 15%. Maximum reduction in wall thickness took place near the water inlet ends. No denting type phenomenon was observed at the tube to tube-support plate crevice locations. At certain locations on ID surfaces of some tubes, small steps, 0.2 mm high, were noticed along the longitudinal direction of the tubes. ID surfaces of the tubes were covered with light gray coloured thin and adherent corrosion products decorated with red spots at places. EDAX analysis showed that these red spots were enriched with copper. While some pits were present on the ID surfaces, the OD surfaces were covered with shining black oxide film. Fracture surfaces of the tubes, which had lost much strength and broke while taking them out of the condenser, showed presence of cleavages with fatigue striations near the OD edges. Mechanical properties of the tubes as such had deteriorated significantly. The tubes were observed to have been degraded to a large extent due to localised corrosion on the ID surfaces and corrosion fatigue damage caused by flow induced vibration. Under the present operational conditions, the tubes are expected to perform satisfactorily for a limited period. (author)

  6. The use of titanium for condenser tube bundles

    International Nuclear Information System (INIS)

    Dobrowitch, Nicolas

    2003-01-01

    In a power plant, the condenser is a strategic heat exchanger with regards to the efficiency of the steam turbine and its reliability guarantees the performance and continuous operation of the plant. Until the early 1980s, copper alloys were routinely used in condenser tubes, thanks to their high heat transfer rates. Yet, numerous problems arose from the use of this material, such as stress corrosion cracking, ammoniacal corrosion, fouling, erosion, dezincification, abrasion, erosion-corrosion, etc. and lately the problem of the inadequacy of copper with nuclear steam generators. The trend was then to consider new tube materials, such as stainless steel and titanium, at first for particular operating conditions and now for most of the projects, with several objectives, such as: improving reliability (titanium in particular can bring major improvements including higher water velocities promoting better heat transfer coefficients, and excellent resistance to abrasion, erosion and corrosion thereby improving resistance to fouling); finding more cost-effective solutions. The first investment is higher but money is saved on maintenance costs and on time reliability of the material. (orig.)

  7. Improved condenser design and condenser-fan operation for air-cooled chillers

    International Nuclear Information System (INIS)

    Yu, F.W.; Chan, K.T.

    2006-01-01

    Air-cooled chillers traditionally operate under head pressure control via staging constant-speed condenser fans. This causes a significant drop in their coefficient of performance (COP) at part load or low outdoor temperatures. This paper describes how the COP of these chillers can be improved by a new condenser design, using evaporative pre-coolers and variable-speed fans. A thermodynamic model for an air-cooled screw-chiller was developed, within which the condenser component considers empirical equations showing the effectiveness of an evaporative pre-cooler in lowering the outdoor temperature in the heat-rejection process. The condenser component also contains an algorithm to determine the number and speed of the condenser fans staged at any given set point of condensing temperature. It is found that the chiller's COP can be maximized by adjusting the set point based on any given chiller load and wet-bulb temperature of the outdoor air. A 5.6-113.4% increase in chiller COP can be achieved from the new condenser design and condenser fan operation. This provides important insights into how to develop more energy-efficient air-cooled chillers

  8. Polish society attitudes towards nuclear power, ionizing radiation applications and radioactive waste management (Report on public opinion polls)

    International Nuclear Information System (INIS)

    Latek, Stanislaw

    1999-01-01

    In Poland, during parliamentary debate on Foundations for the 'Polish energy policies up to 2010', the importance of public attitudes toward nuclear power has been recalled repeatedly in the context of the future development of nuclear power in Poland. In the governmental document, accepted by Polish Parliament on 1 January 1996, it has been stated that nuclear power plant construction is not foreseen up to the year 2010; nevertheless it has been assumed that the appraisals of the economic feasibility and of the public acceptance level for such investments will be conducted. Thus, the need for such assessments of public opinions and attitudes toward nuclear power has been recognized and accepted by the highest legislative power organ in Poland

  9. Sensory factors affecting female consumers' acceptability of nail polish.

    Science.gov (United States)

    Sun, C; Koppel, K; Adhikari, K

    2015-12-01

    The objectives of this study were to determine what sensory factors impact consumers' acceptability of nail polishes, to explore how these sensory factors impact consumers' acceptability of nail polishes, to investigate whether there are any consumer segments according to their overall acceptability on different nail polishes and to scrutinize how the consumer segments are related to the sensory factors. Ninety-eight females participated in a nail polish consumer study at Kansas State University. Eight commercial products belonging to four categories - regular (REG), gel (GEL), flake (FLK) and water-based (WAT) - were evaluated. Each nail polish sample was evaluated twice by each participant in two different tasks - a task devoted to applying and evaluating the product and a task devoted to observing the appearance and evaluating the product. Pearson's correlation analysis, analysis of variance (ANOVA), external preference mapping, cluster analysis and internal preference mapping were applied for data analysis. Participants' scores of overall liking of the nail polishes were similar in the application task and in the observation task. In general, participants liked the REG and GEL product samples more than the FLK and WAT samples. Among all the sensory attributes, appearance attributes were the major factors that affected participants' overall liking. Aroma seemed to be a minor factor to participants' overall liking. Some sensory attributes, such as runny, shininess, opacity, spreadability, smoothness, coverage and wet appearance, were found to drive participants' overall acceptability positively, whereas others such as pinhole, fatty-edges, blister, brushlines, pearl-like, flake-protrusion, glittery and initial-drag impacted participants' overall acceptability negatively. Four clusters of participants were identified according to their overall liking scores from both the application task and the observation task. Participants' acceptability, based on different

  10. POLISH STUDIES OF THE MEDICAL TRADITIONS OF THE AINU.

    Science.gov (United States)

    Arabas, Iwona; Asada, Shoji

    2015-01-01

    Present knowledge of the history of Ainu culture is owed in significant part to Polish Far-East researchers Bronisław Piłsudski (1866-1918) and Wacław Sieroszewski (1858-1945). They were both exiled to Siberia for their patriotic activity at the time where Poles struggled for independence. Bronisław Piłsudski is known for using glass photographic plates and wax recording cylinders for recording the already disappearing culture of the Ainu people. It is thanks to his research that we are able today to trace back the names of over 100 plants that had therapeutic, and as believed by Ainu, also magical power. The plants with the highest therapeutic significance had common characteristics: strong effects, intensive scent and stings. Nowadays, the Ainu people constitute an ethnic minority in Japan (population of over 20 000) and are supported by the Center for Ainu and Indigenous Studies at the Hokkaido University in Sapporo.

  11. Note on the polishing of small spheres of ferrimagnetic materials

    Energy Technology Data Exchange (ETDEWEB)

    Grunberg, J. G.; Antier, G. [Centre d' etudes nucleaires de Grenoble - C.E.N.G. (France); Seiden, P. E. [Institut Fourier, Universite de Grenoble (France)

    1961-07-01

    This note describes a simple and rapid method that we have used for obtaining a high degree of polish on spheres of ferrimagnetic materials. A high surface polish is of particular importance if one desires to perform ferrimagnetic resonance experiments on very narrow linewidth materials such as Yttrium Iron Garnet. It is not possible to obtain the very narrow linewidths without polishing the sample with a very fine abrasive such as 'Linde A'. Although the methods presently used for the fine polishing of ferrite spheres give satisfactory results, the method described here is of particular interest because of its simplicity and speed. For example with the air-jet tumbling technique it can take as long as three days of polishing to obtain an acceptable surface while our method will give the same results in one to two hours. (author)

  12. Polish energy-system modernisation

    International Nuclear Information System (INIS)

    Drozdz, M.

    2003-01-01

    The Polish energy-system needs intensive investments in new technologies, which are energy efficient, clean and cost effective. Since the early 1990s, the Polish economy has had practically full access to modern technological devices, equipment and technologies. Introducing new technologies is a difficult task for project teams, constructors and investors. The author presents a set of principles for project teams useful in planning and energy modernisation. Several essential features are discussed: Energy-efficient appliances and systems; Choice of energy carriers, media and fuels; Optimal tariffs, maximum power and installed power; Intelligent, integrated, steering systems; Waste-energy recovery; Renewable-energy recovery. In practice there are several difficulties connected with planning and realising good technological and economic solutions. The author presents his own experiences of energy-system modernisation of industrial processes and building new objects. (Author)

  13. Initial polishing time affects gloss retention in resin composites.

    Science.gov (United States)

    Waheeb, Nehal; Silikas, Nick; Watts, David

    2012-10-01

    To determine the effect of finishing and polishing time on the surface gloss of various resin-composites before and after simulated toothbrushing. Eight representative resin-composites (Ceram X mono, Ceram X duo, Tetric EvoCeram, Venus Diamond, EsteliteSigma Quick, Esthet.X HD, Filtek Supreme XT and Spectrum TPH) were used to prepare 80 disc-shaped (12 mm x 2 mm) specimens. The two step system Venus Supra was used for polishing the specimens for 3 minutes (Group A) and 10 minutes (Group B). All specimens were subjected to 16,000 cycles of simulated toothbrushing. The surface gloss was measured after polishing and after brushing using the gloss meter. Results were evaluated using one way ANOVA, two ways ANOVA and Dennett's post hoc test (P = 0.05). Group B (10-minute polishing) resulted in higher gloss values (GV) for all specimens compared to Group A (3 minutes). Also Group B showed better gloss retention compared to Group A after simulated toothbrushing. In each group, there was a significant difference between the polished composite resins (P gloss after the simulated toothbrushing.

  14. Surry Power Station secondary water chemistry improvement since steam generator replacement and the unit two feedwater pipe rupture

    International Nuclear Information System (INIS)

    Swindell, E.T.

    1988-01-01

    Surry Power Station has two Westinghouse-designed three-loop PWRs of 811 MWe design rating. The start of commercial operation was in July, 1972 in No.1 plant, and May, 1973 in No.2 plant. Both plants began the operation using controlled phosphate chemistry for the steam generators. In 1975, both plants were converted to all volatile treatment on the secondary side due to the tube wall thinning corrosion in the steam generators, which was associated with the phosphate sludge that was building up on the tube sheets and created acidic condition. Thereafter, condenser and air leakage and steam generator denting occurred, and after the operation of 8 years 2 month of No.1 plant and 5 years 9 months of No.2 plant, the steam generators were replaced. A major plant improvement program was designed and implemented from 1979 to 1980. The improvement in new steam generators, the modification for preventing corrosion, the addition of a steam generator blowdown recovery system, the reconstruction of condensers, the installation of full flow, deep bed condensate polishers, the addition of Dionex 8,000 on-line ion chromatograph, a long term maintenance agreement with Westinghouse and so on are reported. (Kako, I.)

  15. Sexual Health of Polish Athletes with Disabilities

    Directory of Open Access Journals (Sweden)

    Ryszard Plinta

    2015-06-01

    Full Text Available The purpose of this study was to determine sexual functioning of Polish athletes with disabilities (including paralympians. The study encompassed 218 people with physical disabilities, aged between 18 and 45 (149 men and 69 women. The entire research population was divided into three groups: Polish paralympians (n = 45, athletes with disabilities (n = 126 and non-athletes with disabilities (n = 47. The quality of sexual life of Polish paralympians was measured by using the Polish version of Female Sexual Function Index and International Index of Erectile Function. Clinically significant erectile dysfunctions were most often diagnosed in non-athletes (83.33% with 50% result of severe erectile dysfunctions, followed by athletes and paralympians with comparable results of 56.98% and 54.17% respectively (p = 0.00388. Statistically significant clinical sexual dysfunctions concerned lubrication, orgasm as well as pain domains, and prevailed among female non-athletes (68.42%, 68.42% and 57.89%. Practising sports at the highest level has a favourable effect on the sexuality of men and women with physical disabilities. Men with physical disabilities manifest more sexual disorders than women, an aspect which should be considered by health-care professionals working with people with disabilities.

  16. State of the Art Report On Condensation Phenomena Within Tubes in the Presence of Noncondensable Gas

    International Nuclear Information System (INIS)

    Polo, J.

    1998-01-01

    Condensation phenomena play an important role in many industrial applications; in particular; the nuclear industry uses such processes in different systems for both operation and safety aspects. Thus most of the engineering safety features in the current Light Water Reactor (LWR) plants as well as in the new advanced/passive type design are based on the condensation phenomena inside tubes to reduce the system pressure and to remove the decay heat released under accidental conditions. Regarding the new advanced/passive plant designs such a systems must ensure their capabilities under severe accident conditions, that means, under the presence of non-condensable gas an even aerosol particles. The presence of even a small quantity of non condensable gas in liquid-vapour has profound influence on the resistance to heat transfer at the liquid-vapour interface leading to reduce in the heat transfer rate. In consequence, the safety analysis of the Simplified Boiling Water Reactor (SBWR) promoted in increase in the modelling, model development and experimental research on the gas mixtures condensing inside vertical tubes. This report summarises the last models developed as well as the experimental findings on such processes. (Author) 51 refs

  17. Restriction analysis of genetic variability of Polish isolates of Tomato black ring virus.

    Science.gov (United States)

    Jończyk, Magdalena; Borodynko, Natasza; Pospieszny, Henryk

    2004-01-01

    Several different isolates of Tomato black ring virus (TBRV) have been collected in Poland from cucumber, tomato, potato and black locust plants. Biological tests showed some differences in the range of infected plants and the type of symptoms, which was the basis for selection of seven the most biologically different TBRV isolates. According to the sequence of TBRV-MJ, several primer pairs were designed and almost the entire sequence of both genomic RNAs was amplified. The RT-PCR products derived from all tested TBRV isolates were digested by restriction enzymes. On the basis of the restriction patterns, the variable and the conserved regions of the TBRV genome were defined and the relationships between the Polish TBRV isolates established.

  18. Novel cavitation fluid jet polishing process based on negative pressure effects.

    Science.gov (United States)

    Chen, Fengjun; Wang, Hui; Tang, Yu; Yin, Shaohui; Huang, Shuai; Zhang, Guanghua

    2018-04-01

    Traditional abrasive fluid jet polishing (FJP) is limited by its high-pressure equipment, unstable material removal rate, and applicability to ultra-smooth surfaces because of the evident air turbulence, fluid expansion, and a large polishing spot in high-pressure FJP. This paper presents a novel cavitation fluid jet polishing (CFJP) method and process based on FJP technology. It can implement high-efficiency polishing on small-scale surfaces in a low-pressure environment. CFJP uses the purposely designed polishing equipment with a sealed chamber, which can generate a cavitation effect in negative pressure environment. Moreover, the collapse of cavitation bubbles can spray out a high-energy microjet and shock wave to enhance the material removal. Its feasibility is verified through researching the flow behavior and the cavitation results of the negative pressure cavitation machining of pure water in reversing suction flow. The mechanism is analyzed through a computational fluid dynamics simulation. Thus, its cavitation and surface removal mechanisms in the vertical CFJP and inclined CFJP are studied. A series of polishing experiments on different materials and polishing parameters are conducted to validate its polishing performance compared with FJP. The maximum removal depth increases, and surface roughness gradually decreases with increasing negative outlet pressures. The surface becomes smooth with the increase of polishing time. The experimental results confirm that the CFJP process can realize a high material removal rate and smooth surface with low energy consumption in the low-pressure environment, together with compatible surface roughness to FJP. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Condensation coefficient of water in a weak condensation state

    International Nuclear Information System (INIS)

    Kobayashi, Kazumichi; Watanabe, Shunsuke; Yamano, Daigo; Yano, Takeru; Fujikawa, Shigeo

    2008-01-01

    The condensation coefficient of water at a vapor-liquid interface is determined by combining shock tube experiments and numerical simulations of the Gaussian-BGK Boltzmann equation. The time evolution in thickness of a liquid film, which is formed on the shock tube endwall behind the shock wave reflected at the endwall, is measured with an optical interferometer consisting of the physical beam and the reference one. The reference beam is utilized to eliminate systematic noises from the physical beam. The growth rate of the film is evaluated from the measured time evolution and it is incorporated into the kinetic boundary condition for the Boltzmann equation. From a numerical simulation using the boundary condition, the condensation coefficient of water is uniquely deduced. The results show that, in a condition of weak condensation near a vapor-liquid equilibrium state, the condensation coefficient of water is almost equal to the evaporation coefficient estimated by molecular dynamics simulations near a vapor-liquid equilibrium state and it decreases as the system becomes a nonequilibrium state. The condensation coefficient of water is nearly identical with that of methanol [Mikami, S., Kobayashi, K., Ota, T., Fujikawa, S., Yano, T., Ichijo, M., 2006. Molecular gas dynamics approaches to interfacial phenomena accompanied with condensation. Exp. Therm. Fluid Sci. 30, 795-800].

  20. Condensation coefficient of water in a weak condensation state

    Science.gov (United States)

    Kobayashi, Kazumichi; Watanabe, Shunsuke; Yamano, Daigo; Yano, Takeru; Fujikawa, Shigeo

    2008-07-01

    The condensation coefficient of water at a vapor-liquid interface is determined by combining shock tube experiments and numerical simulations of the Gaussian-BGK Boltzmann equation. The time evolution in thickness of a liquid film, which is formed on the shock tube endwall behind the shock wave reflected at the endwall, is measured with an optical interferometer consisting of the physical beam and the reference one. The reference beam is utilized to eliminate systematic noises from the physical beam. The growth rate of the film is evaluated from the measured time evolution and it is incorporated into the kinetic boundary condition for the Boltzmann equation. From a numerical simulation using the boundary condition, the condensation coefficient of water is uniquely deduced. The results show that, in a condition of weak condensation near a vapor-liquid equilibrium state, the condensation coefficient of water is almost equal to the evaporation coefficient estimated by molecular dynamics simulations near a vapor-liquid equilibrium state and it decreases as the system becomes a nonequilibrium state. The condensation coefficient of water is nearly identical with that of methanol [Mikami, S., Kobayashi, K., Ota, T., Fujikawa, S., Yano, T., Ichijo, M., 2006. Molecular gas dynamics approaches to interfacial phenomena accompanied with condensation. Exp. Therm. Fluid Sci. 30, 795-800].

  1. Presentation of the verbs in Bulgarian-Polish electronic dictionary

    Directory of Open Access Journals (Sweden)

    Ludmila Dimitrova

    2014-09-01

    Full Text Available Presentation of the verbs in Bulgarian-Polish electronic dictionary This paper briefly discusses the presentation of the verbs in the first electronic Bulgarian-Polish dictionary that is currently being developed under a bilateral collaboration between IMI-BAS and ISS-PAS. Special attention is given to the digital entry classifiers that describe Bulgarian and Polish verbs. Problems related to the correspondence between natural language phenomena and their presentations are discussed. Some examples illustrate the different types of dictionary entries for verbs.

  2. "Agricultural budget" and the competitiveness of the Polish agriculture

    OpenAIRE

    Lenkiewicz, Stanisław; Rokicki, Bartłomiej

    2014-01-01

    The aim of the publication is to assess the impact of public support on the functioning of the Polish agriculture. In order to achieve this aim the publication includes an analysis of the system of direct payments and rural development policy instruments planned to be implemented in Poland within the CAP 2014-2020. The study also presents an analysis of regional diversity of the Polish agriculture and an assessment of the scale of agricultural investment made in recent years in all the Polish...

  3. Mobile polishing system of feedwater at start-up feedback from the implementation and future prospects

    International Nuclear Information System (INIS)

    Faure, Celine; Eade, Kevin; Fontan, Guillaume

    2012-09-01

    The reduction of the quantity of Steam Generator (SG) metallic oxides deposits, and maintaining a good chemical composition of the secondary side of SG tubes are some of the main objectives being looked at, in order to reduce the risk of SG corrosion, regardless of the alloy used, right from the start-up phase. For all types of outage, obtaining and maintaining sufficient chemical cleanliness at the start-up requires treatment of the water. The treatments are notably: - Water movements using the purge / make-up water method until the chemical criteria have been met. This method can be long and generate large volumes of discharge. - Using suitable resins to remove pollutants from the water. The advantage of this method is that it is selective. - Filtration, allowing for the removal of any insoluble agent. In order to optimise the start-up process, Gravelines and Blayais Nuclear Power Plants (NPPs) put trials in place towards the end of the 1980s. These trials lead to a water supply treatment installation (mobile polishing system- in French Systeme Mobile d'Epuration, SME) being put in place for the start-up phase, made up of an up-stream filter, a mixed-bed resin pollutant trap and a down-stream filter to prevent losing the fines into the feedwater. At the same time, the manifestation of cracking on the secondary side of the steam generator tubes lead EDF to roll out a water treatment for the feedwater dedicated to the start-up. The choice was made not to install a condensate polishing plant, in order to limit notably the pollution risks (resin leaks or waste from the regeneration in the backwater) following difficulties during regeneration. The positive results from the first trials validated for EDF the choice to give priority to the roll-out of the SME to the NPPs judged to be most critical due to the SG material. The SME, installed on a mobile base, can be used on different units at the same station; this reduced the investment and maintenance costs, and

  4. Maintaining steam/condensate lines

    International Nuclear Information System (INIS)

    Russum, S.A.

    1992-01-01

    Steam and condensate systems must be maintained with the same diligence as the boiler itself. Unfortunately, they often are not. The water treatment program, critical to keeping the boiler at peak efficiency and optimizing operating life, should not stop with the boiler. The program must encompass the steam and condensate system as well. A properly maintained condensate system maximizes condensate recovery, which is a cost-free energy source. The fuel needed to turn the boiler feedwater into steam has already been provided. Returning the condensate allows a significant portion of that fuel cost to be recouped. Condensate has a high heat content. Condensate is a readily available, economical feedwater source. Properly treated, it is very pure. Condensate improves feedwater quality and reduces makeup water demand and pretreatment costs. Higher quality feedwater means more reliable boiler operation

  5. Computer-Controlled Cylindrical Polishing Process for Development of Grazing Incidence Optics for Hard X-Ray Region

    Science.gov (United States)

    Khan, Gufran Sayeed; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    The presentation includes grazing incidence X-ray optics, motivation and challenges, mid spatial frequency generation in cylindrical polishing, design considerations for polishing lap, simulation studies and experimental results, future scope, and summary. Topics include current status of replication optics technology, cylindrical polishing process using large size polishing lap, non-conformance of polishin lap to the optics, development of software and polishing machine, deterministic prediction of polishing, polishing experiment under optimum conditions, and polishing experiment based on known error profile. Future plans include determination of non-uniformity in the polishing lap compliance, development of a polishing sequence based on a known error profile of the specimen, software for generating a mandrel polishing sequence, design an development of a flexible polishing lap, and computer controlled localized polishing process.

  6. Effects of Polishing Bur Application Force and Reuse on Sintered Zirconia Surface Topography.

    Science.gov (United States)

    Fischer, N G; Tsujimoto, A; Baruth, A G

    2018-03-16

    Limited information is available on how to polish and finish zirconia surfaces following computer-aided design/computer-aided manufacturing (CAD/CAM), specifically, how differing application forces and reuse of zirconia polishing systems affect zirconia topography. To determine the effect of differing, clinically relevant, polishing application forces and multiple usages of polishing burs on the surface topography of CAD/CAM zirconia. One hundred twenty 220-grit carbide finished zirconia disks were sintered according to manufacturer's directions and divided into two groups for the study of two coarse polishing bur types. Each group was divided into subgroups for polishing (15,000 rpm) at 15 seconds for 1.0 N, 4.5 N, or 11 N of force using a purpose-built fixture. Subgroups were further divided to study the effects of polishing for the first, fifth, 15th, and 30th bur use, simulating clinical procedures. Unpolished surfaces served as a control group. Surfaces were imaged with noncontact optical profilometry (OP) and atomic force microscopy (AFM) to measure average roughness values (Ra). Polishing burs were optically examined for wear. Scanning electron microscopy (SEM) was performed on burs and zirconia surfaces. One-way ANOVA with post hoc Tukey HSD (honest significant difference) tests (α=0.05) were used for statistical analyses. AFM and OP Ra values of all polished surfaces were significantly lower than those of the unpolished control. Different polishing forces and bur reuse showed no significant differences in AFM Ra. However, significant differences in OP Ra were found due to differing application forces and bur reuse between the first and subsequent uses. SEM and optical micrographs revealed notable bur wear, increasing with increasing reuse. SEM and AFM micrographs clearly showed polished, periodic zirconia surfaces. Nanoscale topography, as analyzed with kurtosis and average groove depth, was found dependent on the specific polishing bur type. These in

  7. Enhanced Condensation Heat Transfer

    Science.gov (United States)

    Rose, John Winston

    The paper gives some personal observations on various aspects of enhanced condensation heat transfer. The topics discussed are external condensation (horizontal low-finned tubes and wire-wrapped tubes), internal condensation (microfin tubes and microchannels) and Marangoni condensation of binary mixtures.

  8. The Czechoslovak-Polish Club in Brno (1925–1939)

    Czech Academy of Sciences Publication Activity Database

    Baron, Roman

    2011-01-01

    Roč. 3, č. 1 (2011), s. 43-64 ISSN 1803-6546 Institutional research plan: CEZ:AV0Z80150510 Keywords : Czechoslovak-Polish solidarity * Czechoslovak-Polish relations * Brno * associations * Interwar Period Subject RIV: AB - History

  9. Condensation induced water hammer (CIWH). Relevance in the nuclear industry and state of science and technology

    Energy Technology Data Exchange (ETDEWEB)

    Swidersky, Harald [TUeV Sued Industrie Service GmbH, Muenchen (Germany)

    2013-03-15

    Condensation-induced water hammers (CIWH) are consequences of rapid condensation of steam in partially filled pipes. They present a particular hazard potential, as they seem to occur spontaneously and out of stagnation. The entire process still eludes a secured analytical or numerical predictability and determination of the fluid dynamic loads. The simulation of these processes is one of the most difficult tasks of thermal hydraulic transient analyses. Condensation induced water hammers in plants - mostly power plants - can lead to significant costs if they result in long downtimes, detailed analyses and upgrades. In this contribution, the phenomenon CIWH is explained and the relevance for nuclear engineering will be discussed. An outlook on the actual requirements of regulatory guidelines and the state of science and technology will be given. (orig.)

  10. Condensation induced water hammer (CIWH). Relevance in the nuclear industry and state of science and technology

    International Nuclear Information System (INIS)

    Swidersky, Harald

    2013-01-01

    Condensation-induced water hammers (CIWH) are consequences of rapid condensation of steam in partially filled pipes. They present a particular hazard potential, as they seem to occur spontaneously and out of stagnation. The entire process still eludes a secured analytical or numerical predictability and determination of the fluid dynamic loads. The simulation of these processes is one of the most difficult tasks of thermal hydraulic transient analyses. Condensation induced water hammers in plants - mostly power plants - can lead to significant costs if they result in long downtimes, detailed analyses and upgrades. In this contribution, the phenomenon CIWH is explained and the relevance for nuclear engineering will be discussed. An outlook on the actual requirements of regulatory guidelines and the state of science and technology will be given. (orig.)

  11. Influence of polishing on surface roughness following toothbrushing wear of composite resins.

    Science.gov (United States)

    Dalla-Vecchia, Karine Battestin; Taborda, Talita Damas; Stona, Deborah; Pressi, Heloísa; Burnett Júnior, Luiz Henrique; Rodrigues-Junior, Sinval Adalberto

    2017-01-01

    This study aimed to evaluate the influence of different polishing systems on the surface roughness of composite resins following procedures to simulate the effects of toothbrushing over time. Four currently available commercial composites were used to make 128 cylindrical specimens. The specimens were randomly allocated to polishing with a 1-step polisher or 1 of 3 multistep polishers (n = 8 per group). The baseline surface roughness was measured, and the specimens were submitted to 5000, 10,000, and 20,000 brushing cycles to represent toothbrushing throughout 6, 12, and 24 months, respectively. Results showed that surface roughness was influenced by the type of composite and polishing system and was not influenced by the simulated toothbrushing time. However, the surface roughness, as challenged by toothbrushing wear, was affected by the interaction among the composite, the polisher, and the toothbrushing time. The 1-step polisher produced the highest surface roughness and influenced toothbrushing wear resistance of some composites.

  12. A preliminary study on HTGR with air-cooled condenser at Riyadh, Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Jonghwa; Lee, Wonjae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    N GNP reactor plant adopted a Rank in steam cycle for early deployment and for reducing R and D risk and cost. Original plant design is based on a wet cooling tower with wet bulb temperature of 34 .deg. C. This cooling environment may be sufficient for most area in North America. However, we should consider air temperature of 45 .deg. C and no available cooling water for any site near Riyadh, Saudi Arabia. A plausible option in such arid area is using an air-cooled condenser(ACC) which is widely used in a combined cycle plant in arid region. ACC is also suitable for freezing area such as northern territory or high elevation remote area. We have studied impact of the cooling method on the power generation efficiency and the annual average power production referencing N GNP steam turbine. Even though condenser split is assumed to be the same between ACC and wet cooling tower, large difference in air temperature and wet bulb temperature makes large efficiency loss in the ACC. The ACC efficiency is lower than that of the wet cooling tower by 1.12%. To make up this loss, we proposed the variable steam extraction rates operation. An air cooled condenser is a practical.

  13. Surface analysis of polished fused-silica laser lenses by ion-scattering spectrometry

    International Nuclear Information System (INIS)

    Orvek, K.; Steward, S.A.

    1982-01-01

    New advances in high-powered glass lasers, particularly the NOVA system, have resulted in a need for lenses having higher damage threshold values than those now available. It is currently thought that surface contaminants on the lenses are responsible for initiating part of the damage. These contaminants are apparently introduced during the final polishing stages. In this study, we used ion-scattering spectrometry (ISS) to identify contaminants arising through the use of different polishing techniques. Five lenses were studied, each having undergone different polishing procedures. The first lens was not polished after receiving it from the manfacturer (No. 381). Ion microprobe data were available for this lens, and they were compared to ISS results. The second lens had been polished with rouge, a polishing compound no longer in use (No. 796). This sample served as a further check on the ISS results. The third lens was studied as received from the manufacturer - with no handling or cleaning (No. 802). The final two lenses had both been polished using high-purity ceria, cerium oxide (No. 800 and No. 801). The difference between these two was that No. 800 was polished using a nylon lap, and No. 801 was polished using pitch as a lap. The 800-series lenses were all made from the same batch, and constituted the major part of the investigation

  14. The nucleotide sequence of a Polish isolate of Tomato torrado virus.

    Science.gov (United States)

    Budziszewska, Marta; Obrepalska-Steplowska, Aleksandra; Wieczorek, Przemysław; Pospieszny, Henryk

    2008-12-01

    A new virus was isolated from greenhouse tomato plants showing symptoms of leaf and apex necrosis in Wielkopolska province in Poland in 2003. The observed symptoms and the virus morphology resembled viruses previously reported in Spain called Tomato torrado virus (ToTV) and that in Mexico called Tomato marchitez virus (ToMarV). The complete genome of a Polish isolate Wal'03 was determined using RT-PCR amplification using oligonucleotide primers developed against the ToTV sequences deposited in Genbank, followed by cloning, sequencing, and comparison with the sequence of the type isolate. Phylogenetic analyses, performed on the basis of fragments of polyproteins sequences, established the relationship of Polish isolate Wal'03 with Spanish ToTV and Mexican ToMarV, as well as with other viruses from Sequivirus, Sadwavirus, and Cheravirus genera, reported to be the most similar to the new tomato viruses. Wal'03 genome strands has the same organization and very high homology with the ToTV type isolate, showing only some nucleotide and deduced amino acid changes, in contrast to ToMarV, which was significantly different. The phylogenetic tree clustered aforementioned viruses to the same group, indicating that they have a common origin.

  15. 1.06 μm 150 psec laser damage study of diamond turned, diamond turned/polished and polished metal mirrors

    International Nuclear Information System (INIS)

    Saito, T.T.; Milam, D.; Baker, P.; Murphy, G.

    1975-01-01

    Using a well characterized 1.06 μm 150 ps glass laser pulse the damage characteristics for diamond turned, diamond turned/ polished, and polished copper and silver mirrors less than 5 cm diameter were studied. Although most samples were tested with a normal angle of incidence, some were tested at 45 0 with different linear polarization showing an increase in damage threshold for S polarization. Different damage mechanisms observed will be discussed. Laser damage is related to residual surface influences of the fabrication process. First attempts to polish diamond turned surfaces resulted in a significant decrease in laser damage threshold. The importance of including the heat of fusion in the one dimensional heat analysis of the theoretical damage threshold and how close the samples came to the theoretical damage threshold is discussed. (auth)

  16. The study of optimization on process parameters of high-accuracy computerized numerical control polishing

    Science.gov (United States)

    Huang, Wei-Ren; Huang, Shih-Pu; Tsai, Tsung-Yueh; Lin, Yi-Jyun; Yu, Zong-Ru; Kuo, Ching-Hsiang; Hsu, Wei-Yao; Young, Hong-Tsu

    2017-09-01

    Spherical lenses lead to forming spherical aberration and reduced optical performance. Consequently, in practice optical system shall apply a combination of spherical lenses for aberration correction. Thus, the volume of the optical system increased. In modern optical systems, aspherical lenses have been widely used because of their high optical performance with less optical components. However, aspherical surfaces cannot be fabricated by traditional full aperture polishing process due to their varying curvature. Sub-aperture computer numerical control (CNC) polishing is adopted for aspherical surface fabrication in recent years. By using CNC polishing process, mid-spatial frequency (MSF) error is normally accompanied during this process. And the MSF surface texture of optics decreases the optical performance for high precision optical system, especially for short-wavelength applications. Based on a bonnet polishing CNC machine, this study focuses on the relationship between MSF surface texture and CNC polishing parameters, which include feed rate, head speed, track spacing and path direction. The power spectral density (PSD) analysis is used to judge the MSF level caused by those polishing parameters. The test results show that controlling the removal depth of single polishing path, through the feed rate, and without same direction polishing path for higher total removal depth can efficiently reduce the MSF error. To verify the optical polishing parameters, we divided a correction polishing process to several polishing runs with different direction polishing paths. Compare to one shot polishing run, multi-direction path polishing plan could produce better surface quality on the optics.

  17. Electrolytic polishing system for space age materials

    International Nuclear Information System (INIS)

    Coons, W.C.; Iosty, L.R.

    1976-01-01

    A simple electrolytic polishing technique was developed for preparing Cr, Co, Hf, Mo, Ni, Re, Ti, V, Zr, and their alloys for structural analysis on the optical microscope. The base electrolyte contains 5g ZnCl 2 and 15g AlCl 3 . 6H 2 O in 200 ml methyl alcohol, plus an amount of H 2 SO 4 depending on the metal being polished. Five etchants are listed

  18. Effects of different polishing techniques on the surface roughness of dental porcelains

    Directory of Open Access Journals (Sweden)

    Işil Sarikaya

    2010-02-01

    Full Text Available OBJECTIVE: The purpose of this study was to evaluate the effects of different polishing techniques on the surface roughness of dental porcelains. MATERIAL AND METHODS: Fifty-five cylindirical specimens (15x2 mm were prepared for each feldspathic (Vita VMK 95, Ceramco III and low-fusing dental porcelain (Matchmaker. Fifty-five specimens of machinable feldspathic porcelain blocks (Vitablocs Mark II, (12x14x18 mm were cut into 2-mm-thick slices (12x14 mm with low speed saw. The prepared specimens were divided into 11 groups (n=5 representing different polishing techniques including control ((C no surface treatment, glaze (G and other 9 groups that were finished and polished with polishing discs (Sof-Lex (Sl, two porcelain polishing kits (NTI (Pk, Dialite II (Di, a diamond polishing paste (Sparkle (Sp, a zirconium silicate based cleaning and polishing prophy paste (Zircate (Zr, an aluminum oxide polishing paste (Prisma Gloss (Pg, and combinations of them. The surface roughness of all groups was measured with a profilometer. The data were analyzed with a 2-way analysis of variance, and the mean values were compared by the Tukey Honestly Significant Difference test (a=0.05. RESULTS: For all porcelain material groups, the lowest Ra values were observed in Group Gl, Group Sl, Group Pk, and Group Di, which were not significantly different from each other (p>0.05.When comparing the 4 different porcelain materials, the machinable feldspathic porcelain block group (Mark II demonstrated statistically significantly less Ra values than the other porcelain materials tested (p<0.05. No significant difference was observed between the VMK 95 and Ceramco III porcelain groups (p=0.919, also these groups demonstrated the highest Ra values. CONCLUSION: Subjected to surface roughness, the surfaces obtained with polishing and/or cleaning-prophy paste materials used alone were rougher compared to the surfaces finished using Sof-lex, Dialite, and NTI polishing kit

  19. Polish Phoneme Statistics Obtained On Large Set Of Written Texts

    Directory of Open Access Journals (Sweden)

    Bartosz Ziółko

    2009-01-01

    Full Text Available The phonetical statistics were collected from several Polish corpora. The paper is a summaryof the data which are phoneme n-grams and some phenomena in the statistics. Triphonestatistics apply context-dependent speech units which have an important role in speech recognitionsystems and were never calculated for a large set of Polish written texts. The standardphonetic alphabet for Polish, SAMPA, and methods of providing phonetic transcriptions are described.

  20. Polishing compound for plastic surfaces

    Science.gov (United States)

    Stowell, M.S.

    1991-01-01

    This invention is comprised of a polishing compound for plastic materials. The compound includes approximately by approximately by weight 25 to 80 parts at least one petroleum distillate lubricant, 1 to 12 parts mineral spirits, 50 to 155 parts abrasive paste, and 15 to 60 parts water. Preferably, the compound includes approximately 37 to 42 parts at least one petroleum distillate lubricant, up to 8 parts mineral spirits, 95 to 110 parts abrasive paste, and 50 to 55 parts water. The proportions of the ingredients are varied in accordance with the particular application. The compound is used on PLEXIGLAS{trademark}, LEXAN{trademark}, LUCITE{trademark}, polyvinyl chloride (PVC), and similar plastic materials whenever a smooth, clear polished surface is desired.

  1. Pseudo-random tool paths for CNC sub-aperture polishing and other applications.

    Science.gov (United States)

    Dunn, Christina R; Walker, David D

    2008-11-10

    In this paper we first contrast classical and CNC polishing techniques in regard to the repetitiveness of the machine motions. We then present a pseudo-random tool path for use with CNC sub-aperture polishing techniques and report polishing results from equivalent random and raster tool-paths. The random tool-path used - the unicursal random tool-path - employs a random seed to generate a pattern which never crosses itself. Because of this property, this tool-path is directly compatible with dwell time maps for corrective polishing. The tool-path can be used to polish any continuous area of any boundary shape, including surfaces with interior perforations.

  2. Phonematic translation of Polish texts by the neural network

    International Nuclear Information System (INIS)

    Bielecki, A.; Podolak, I.T.; Wosiek, J.; Majkut, E.

    1996-01-01

    Using the back propagation algorithm, we have trained the feed forward neural network to pronounce Polish language, more precisely to translate Polish text into its phonematic counterpart. Depending on the input coding and network architecture, 88%-95% translation efficiency was achieved. (author)

  3. Secondary coolant purification system

    International Nuclear Information System (INIS)

    Stiteler, F.Z.; Donohue, J.P.

    1978-01-01

    The present invention combines the attributes of volatile chemical addition, continuous blowdown, and full flow condensate demineralization. During normal plant operation (defined as no primary to secondary leakage) condensate from the condenser is pumped through a full flow condensate demineralizer system by the condensate pumps. Volatile chemical additions are made. Dissolved and suspended solids are removed in the condensate polishers by ion exchange and/or filtration. At the same time a continuous blowdown of approximately 1 percent of the main steaming rate of the steam generators is maintained. Radiation detectors monitor the secondary coolant. If these monitors indicate no primary to secondary leakage, the blowdown is cooled and returned directly to the condensate pump discharge. If one of the radiation monitors should indicate a primary to secondary leak, when the temperature of the effluent exiting from the blowdown heat exchanger is compatible with the resin specifications of the ion exchangers, the bypass valve causes the blowdown flow to pass through the blowdown ion exchangers

  4. Investigation of variable compositions on the removal of technetium from Hanford Waste Treatment Plant low activity waste melter off-gas condensate simulant

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, Kathryn M. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, Daniel J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Pareizs, John M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-03-29

    The Low Activity Waste (LAW) vitrification facility at the Hanford Waste Treatment and Immobilization Plant (WTP) will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the offgas system. The plan for disposition of this stream during baseline operations is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. The primary reason to recycle this stream is so that the semi-volatile 99Tc isotope eventually becomes incorporated into the glass. This stream also contains non-radioactive salt components that are problematic in the melter, so diversion of this stream to another process would eliminate recycling of these salts and would enable simplified operation of the LAW melter and the Pretreatment Facilities. This diversion from recycling this stream within WTP would have the effect of decreasing the LAW vitrification mission duration and quantity of glass waste. The concept being tested here involves removing the 99Tc so that the decontaminated aqueous stream, with the problematic salts, can be disposed elsewhere.

  5. Measurement of liquid-liquid equilibria for condensate + glycol and condensate + glycol + water systems

    DEFF Research Database (Denmark)

    Riaz, Muhammad; Kontogeorgis, Georgios; Stenby, Erling Halfdan

    2011-01-01

    ,2-ethanediol (MEG) + condensate and MEG + water + condensate systems at temperatures from (275 to 323) K at atmospheric pressure. The condensate used in this work is a stabilized natural gas condensate from an offshore field in the North Sea. Compositional analysis of the natural gas condensate was carried out...... by gas chromatography, and detailed separation of individual condensate's components has been carried out. Approximately 85 peaks eluting before nonane were identified by their retention time. Peak areas were converted to mass fraction using 1-heptene as an internal standard. The components were divided...... into boiling range groups from hexane to nonane. Paraffinic (P), naphthenic (N), and aromatic (A) distributions were obtained for the boiling point fractions up to nonane. The average molar mass and the overall density of the condensate were measured experimentally. For the mutual solubility of MEG...

  6. Effect of Low Pressure End Conditions on Steam Power Plant Performance

    Directory of Open Access Journals (Sweden)

    Ali Syed Haider

    2014-07-01

    Full Text Available Most of the electricity produced throughout the world today is from steam power plants and improving the performance of power plants is crucial to minimize the greenhouse gas emissions and fuel consumption. Energy efficiency of a thermal power plant strongly depends on its boiler-condenser operating conditions. The low pressure end conditions of a condenser have influence on the power output, steam consumption and efficiency of a plant. Hence, the objective this paper is to study the effect of the low pressure end conditions on a steam power plant performance. For the study each component was modelled thermodynamically. Simulation was done and the results showed that performance of the condenser is highly a function of its pressure which in turn depends on the flow rate and temperature of the cooling water. Furthermore, when the condenser pressure increases both net power output and plant efficiency decrease whereas the steam consumption increases. The results can be used to run a steam power cycle at optimum conditions.

  7. Flue gas condensation in oxyfuel power plants. Heat- and mass transfer measurements and experimental validation of an efficient condensation concept; Rauchgaskondensation in Oxyfuel-Kraftwerken. Waerme- und Stoffuebergangsmessungen sowie experimentelle Validierung eines effizienten Kondensationskonzepts

    Energy Technology Data Exchange (ETDEWEB)

    Raindl, Markus

    2010-12-06

    Condensation of a steam-inert gas mixture in an Oxyfuel condenser differs significantly from condensation of pure steam: condenser pressure and rest gas content increase dramatically, heat- and mass transfer coefficients are lower and oversaturation of the steam-inert gas mixture yields to fog formation. In the context of this thesis, therefore, at first the optimal ranges of working parameters for Oxyfuel processes calculated. In the following some heat flux measurements were carried out on a horizontal, crossflow pipe to validate various heat- and mass transfer theories. Building on these results a new, efficient condensation concept was developed to reduce fog formation. The final results of the measurements with a laboratory model show great performance regarding fog reduction and condensation efficiency. (orig.)

  8. Tribological approach to study polishing of road surface under traffic

    OpenAIRE

    KANE, Malal; DO, Minh Tan

    2007-01-01

    The polishing phenomenon of road pavements under the vehicle traffic constitutes the main mechanism inherent to the loss of skid resistance over time. A better understanding of this phenomenon would allow an improvement of road safety. This study comprises a review of laboratory test and a model simulating the polishing of road surfaces. The laboratory test uses a polishing machine so called 'Wehner-Schulze' which can reproduce the evolution of the road texture from specimens taken directly f...

  9. Low pressure lithium condensation

    International Nuclear Information System (INIS)

    Wadkins, R.P.; Oh, C.H.

    1985-01-01

    A low pressure experiment to evaluate the laminar film condensation coefficients of lithium was conducted. Some thirty-six different heat transfer tests were made at system pressures ranging from 1.3 to 26 Pa. Boiled lithium was condensed on the inside of a 7.6-cm (ID), 409 stainless-steel pipe. Condensed lithium was allowed to reflux back to the pool boiling region below the condensing section. Fourteen chromel/alumel thermocouples were attached in various regions of the condensing section. The thermocouples were initially calibrated with errors of less than one degree Celsius

  10. The place of polish in the multilingual space of the European Union

    Directory of Open Access Journals (Sweden)

    T. I. Neprytska

    2015-03-01

    Full Text Available The article studies the position of the Polish language in the multilingual space of the European Union and determines the key factors which facilitate its gaining popularity and spreading in Europe. A large territory and population determine the significant presence of Polish in the European Union. Intense economic development facilitates popularization of learning and using Polish in the business medium, however, English was and still remains the dominating language of business. Active work of the state on improving the reputation of the country abroad, civilizational (value­based unity with other nations of the EU, favorable geographical position, common Indo­European roots of Germanic, Romanic and Slavonic  languages as well as usage of the Latin type create favorable conditions for the development and popularization of Polish on the territory of the EU. The article also mentions a number of concerns, which are rooted in the historical past of a dependent or semi­dependent existence of the Polish people, namely, the existence of the Polish and culture in the shade of German and Russian culture space, the negative international image of modern Poland, which was formed at the beginning of the 1990­s, the low level of Europeans’ familiarization with the Polish culture, absence of popularity and economic necessity of learning Polish abroad.

  11. SLAC synchronous condenser

    International Nuclear Information System (INIS)

    Corvin, C.

    1995-06-01

    A synchronous condenser is a synchronous machine that generates reactive power that leads real power by 90 degrees in phase. The leading reactive power generated by the condenser offsets or cancels the normal lagging reactive power consumed by inductive and nonlinear loads at the accelerator complex. The quality of SLAC's utility power is improved with the addition of the condenser. The inertia of the condenser's 35,000 pound rotor damps and smoothes voltage excursions on two 12 kilovolt master substation buses, improving voltage regulation site wide. The condenser absorbs high frequency transients and noise in effect ''scrubbing'' the electric system power at its primary distribution source. In addition, the condenser produces a substantial savings in power costs. Federal and investor owned utilities that supply electric power to SLAC levy a monthly penalty for lagging reactive power delivered to the site. For the 1993 fiscal year this totaled over $285,000 in added costs for the year. By generating leading reactive power on site, thereby reducing total lagging reactive power requirements, a substantial savings in electric utility bills is achieved. Actual savings of $150,000 or more a year are possible depending on experimental operations

  12. Research on high-efficiency polishing technology of photomask substrate

    Science.gov (United States)

    Zhao, Shijie; Xie, Ruiqing; Zhou, Lian; Liao, Defeng; Chen, Xianhua; Wang, Jian

    2018-03-01

    A method of photomask substrate fabrication is demonstrated ,that the surface figure and roughness of fused silica will converge to target precision rapidly with the full aperture polishing. Surface figure of optical flats in full aperture polishing processes is primarily dependent on the surface profile of polishing pad, therefor, a improved function of polishing mechanism was put forward based on two axis lapping machine and technology experience, and the pad testing based on displacement sensor and the active conditioning method of the pad is applied in this research. Moreover , the clamping deformation of the thin glass is solved by the new pitch dispensing method. The experimental results show that the surface figure of the 152mm×152mm×6.35mm optical glass is 0.25λ(λ=633nm) and the roughness is 0.32nm ,which has meet the requirements of mask substrate for 90 45nm nodes.

  13. Allocation of synchronous condensers for restoration of system short-circuit power

    DEFF Research Database (Denmark)

    Marrazi, Emanuel; Yang, Guangya; Weinreich-Jensen, Peter

    2017-01-01

    Modern power systems, employing an increasing number of converter-based renewable energy sources (RES) and decreasing the usage of conventional power plants, are leading to lower levels of short-circuit power and rotational inertia. A solution to this is the employment of synchronous condensers...... in the grid, in order to provide sufficient short-circuit power. This results in the increase of the short-circuit ratio (SCR) at transmission system bus-bars serving as points of interconnection (POI) to renewable generation. Evaluation of the required capacity and grid-location of the synchronous condensers......, isinherently a mixed integer non-linear optimization problem, which could not be done on manual basis considering each type of machine and all bus-bars. This study therefore proposes a method of optimal allocation of synchronous condensers in a hypothetic future scenario of a transmission system fed...

  14. Forming a health culture of future teachers in Polish educational establishments

    Directory of Open Access Journals (Sweden)

    T.S. IERMAKOVA

    2014-10-01

    Full Text Available Aim: to study the experience of the structure and system of training of future teachers in Polish schools. Material: content analysis of domestic and foreign authors. Used data from the survey of students of Polish universities. Also were used survey results through polish service ANKIETKA. For comparison, a questionnaire survey 35 students of the Faculty of Physical Education (future teachers of physical training and 30 students - the future teachers of elementary school of Ukrainian university. Results: the study of Polish teachers consider health culture of a person as the ability to assess individual and community health needs using in everyday life hygiene and health regulations. There have been some differences among Ukrainian and Polish students in their health and health culture. Among the respondents, Polish students - the future teachers of physical culture, is dominated motives such as the improvement of the physical condition, strengthen self-esteem, as well as improved health. Polish students from other disciplines believe that the most important motive for the adoption of physical activity is a concern for the physical well-being and mental health. The majority of Ukrainian students (future teachers of physical culture believe an important part of building health culture of their direct participation in various sports clubs, as well as the ability to organize physical culture, sports and educational work with students outside the classroom. Ukrainian students (other specialty noted the need to improve health, enhance knowledge in specific subjects humanities and promoting healthy lifestyles. Conclusions: It is recommended to use the experience of preparing students of Polish schools in modern Ukrainian higher education.

  15. Confocal Raman spectrocopy for the analysis of nail polish evidence.

    Science.gov (United States)

    López-López, Maria; Vaz, Joana; García-Ruiz, Carmen

    2015-06-01

    Nail polishes are cosmetic paints that may be susceptible of forensic analysis offering useful information to assist in a crime reconstruction. Although the nail polish appearance could allow a quick visual identification of the sample, this analysis is subjected to the perception and subjective interpretation of the forensic examiner. The chemical analysis of the nail polishes offers great deal of information not subjected to analyst interpretation. Confocal Raman spectroscopy is a well-suited technique for the analysis of paints due to its non-invasive and non-destructive nature and its ability to supply information about the organic and inorganic components of the sample. In this work, 77 regular and gel nail polishes were analyzed with confocal Raman spectroscopy using two laser wavelengths (532 and 780 nm). The sample behavior under the two laser wavelengths and the differences in the spectra taken at different points of the sample were studied for each nail polish. Additionally, the spectra obtained for all the nail polishes were visually compared. The results concluded that the longer laser wavelength prevents sample burning and fluorescence effects; the similarity among the spectra collected within the sample is not directly related with the presence of glitter particles; and 64% of the samples analyzed showed a characteristic spectrum. Additionally, the use of confocal Raman spectroscopy for the forensic analysis of nail polishes evidence in the form of flakes or smudges on different surfaces were studied. The results showed that both types of evidence can be analyzed by the technique. Also, two non-invasive sampling methods for the collection of the evidence from the nails of the suspect or the victim were proposed: (i) to use acetone-soaked cotton swabs to remove the nail varnishes and (ii) to scrape the nail polish from the nail with a blade. Both approaches, each exhibiting advantages and drawbacks in terms of transport and handling were appropriate

  16. Application of a power plant simplification methodology: The example of the condensate feedwater system

    International Nuclear Information System (INIS)

    Seong, P.H.; Manno, V.P.; Golay, M.W.

    1988-01-01

    A novel framework for the systematic simplification of power plant design is described with a focus on the application for the optimization of condensate feedwater system (CFWS) design. The evolution of design complexity of CFWS is reviewed with emphasis upon the underlying optimization process. A new evaluation methodology which includes explicit accounting of human as well as mechanical effects upon system availability is described. The unifying figure of merit for an operating system is taken to be net electricity production cost. The evaluation methodology is applied to the comparative analysis of three designs. In the illustrative examples, the results illustrate how inclusion in the evaluation of explicit availability related costs leads to optimal configurations. These are different from those of current system design practices in that thermodynamic efficiency and capital cost optimization are not overemphasized. Rather a more complete set of design-dependent variables is taken into account, and other important variables which remain neglected in current practices are identified. A critique of the new optimization approach and a discussion of future work areas including improved human performance modeling and different optimization constraints are provided. (orig.)

  17. Novel ceria-polymer microcomposites for chemical mechanical polishing

    International Nuclear Information System (INIS)

    Coutinho, Cecil A.; Mudhivarthi, Subrahmanya R.; Kumar, Ashok; Gupta, Vinay K.

    2008-01-01

    Abrasive particles are key components in slurries for chemical mechanical polishing (CMP). Since the particle characteristics determine surface quality of wafers during polishing, in this research, novel abrasive composite particles have been developed. These composite particles contain nanoparticles of ceria dispersed within cross-linked, polymeric microspheres such that the average mass fraction of ceria is approximately 50% in the particles. The microspheres are formed by co-polymerization of N-isopropylacrylamide (NIPAM) with 3-(trimethoxysilyl)propyl methacrylate (MPS) and contain interpenetrating (IP) chains of poly(acrylic acid) (PAAc). Infrared spectroscopy, dynamic light scattering, and transmission electron microscopy are employed to characterize the composite particles. Planarization of silicon dioxide wafers is studied on a bench-top CMP tester and the polished surfaces are characterized by ellipsometry, atomic force and optical microscopy. Slurries formed from the composite ceria-polymer particles lead to lower topographical variations and surface roughness than slurries of only ceria nanoparticles even though both slurries achieve similar removal rates of ∼100 nm/min for similar ceria content. Polishing with the novel composite particles gives surfaces devoid of scratches and particle deposition, which makes these particles suitable for the next generation slurries in CMP

  18. Novel ceria-polymer microcomposites for chemical mechanical polishing

    Energy Technology Data Exchange (ETDEWEB)

    Coutinho, Cecil A. [Department of Chemical and Biomedical Engineering, University of South Florida (United States); Mudhivarthi, Subrahmanya R.; Kumar, Ashok [Nanomaterials and Nanomanufacturing Research Center, University of South Florida (United States); Department of Mechanical Engineering, University of South Florida (United States); Gupta, Vinay K. [Department of Chemical and Biomedical Engineering, University of South Florida (United States)], E-mail: vkgupta@eng.usf.edu

    2008-12-30

    Abrasive particles are key components in slurries for chemical mechanical polishing (CMP). Since the particle characteristics determine surface quality of wafers during polishing, in this research, novel abrasive composite particles have been developed. These composite particles contain nanoparticles of ceria dispersed within cross-linked, polymeric microspheres such that the average mass fraction of ceria is approximately 50% in the particles. The microspheres are formed by co-polymerization of N-isopropylacrylamide (NIPAM) with 3-(trimethoxysilyl)propyl methacrylate (MPS) and contain interpenetrating (IP) chains of poly(acrylic acid) (PAAc). Infrared spectroscopy, dynamic light scattering, and transmission electron microscopy are employed to characterize the composite particles. Planarization of silicon dioxide wafers is studied on a bench-top CMP tester and the polished surfaces are characterized by ellipsometry, atomic force and optical microscopy. Slurries formed from the composite ceria-polymer particles lead to lower topographical variations and surface roughness than slurries of only ceria nanoparticles even though both slurries achieve similar removal rates of {approx}100 nm/min for similar ceria content. Polishing with the novel composite particles gives surfaces devoid of scratches and particle deposition, which makes these particles suitable for the next generation slurries in CMP.

  19. A REVIEW ON SEWAGE TREATMENT AND POLISHING USING MOVING BED BIOREACTOR (MBBR

    Directory of Open Access Journals (Sweden)

    JAMAL ALI KAWAN

    2016-08-01

    Full Text Available Effluent treatment and polishing using moving bed bioreactors (MBBRs are advanced technique in biological treatment operations become increasing widely and popular use all over the world to treat various types of effluents with very different operating status. It is a combination of two separate processes suspended and attached growth systems for the treatment in order to minimize the concentrations of the contaminated parameters at the required level for reuse or final destination. The MBBR has been proved to be effective in great removing biochemical oxygen demand (BOD and chemical oxygen demand (COD with nutrients (N and P from the effluent stream simultaneously. It provides additional capacity of wastewater treatment technology with high treatment efficiency; low capital, operational, maintenance and replacement cost; single reliable and robust operation procedure. This process can be used for new sewage treatment works or for modifying (upgrading existing wastewater treatment plants as it is efficient, compact and easy to operate. The efficiency of MBBR depends on the filling percent of biofilm carriers to be provided inside the tank, surface area of the biocarrier, diffused aeration supply and the organic loading. The aim of this paper is reviewing the sewage treatment and polishing using moving bed bioreactor MBB technology as an alternative and successful method. It presents the advantages of the MBBR compared to conventional waste water treatment. The review also includes many relevant researches carried out at the laboratory andpilot scales plants that could improve these systems by enhancing performance and reducing costs.

  20. In-operation testing of condensers tubes in EDF thermal power plants

    International Nuclear Information System (INIS)

    Sermadiras, P.; Cormier, J.

    1982-01-01

    Electricite de France requires manufacturers to perform a number of tests on condenser tubes, as it does itself, including eddy current tests. This article describes the worksite inspection procedures, which use internal single-frequency probes to detect the following irregularities: - in differential mode: external corrosion, impacts, foreign matter, vibrations, internal behaviour of tubes; - in absolute mode: corrosion by ammonia [fr

  1. Jewish problem in the Polish Communist Party

    Directory of Open Access Journals (Sweden)

    Cimek Henryk

    2016-12-01

    Full Text Available Jews accounted for approx. 8-10% of the population of the Second Republic and in the communist movement (Polish Communist Party and Polish Communist Youth Union the rate was approx, 30%, while in subsequent years it much fluctuated. The percentage of Jews was the highest in the authorities of the party and in the KZMP. This had a negative impact on the position of the KPP on many issues, especially in its relation to the Second Republic.

  2. Conditions for maximum isolation of stable condensate during separation in gas-condensate systems

    Energy Technology Data Exchange (ETDEWEB)

    Trivus, N.A.; Belkina, N.A.

    1969-02-01

    A thermodynamic analysis is made of the gas-liquid separation process in order to determine the relationship between conditions of maximum stable condensate separation and physico-chemical nature and composition of condensate. The analysis was made by considering the multicomponent gas-condensate fluid produced from Zyrya field as a ternary system, composed of methane, an intermediate component (propane and butane) and a heavy residue, C/sub 6+/. Composition of 5 ternary systems was calculated for a wide variation in separator conditions. At each separator pressure there is maximum condensate production at a certain temperature. This occurs because solubility of condensate components changes with temperature. Results of all calculations are shown graphically. The graphs show conditions of maximum stable condensate separation.

  3. Mercury emissions from polish pulverized coalfired boiler

    Directory of Open Access Journals (Sweden)

    Wichliński Michał

    2017-01-01

    Full Text Available The current paper presents the research results carried out at one of Polish power plants at a pulverized hard coal-fired 225 MW unit. The research was carried out at full load of the boiler (100% MCR and focused on analysis of mercury content in the input fuel and limestone sorbent for wet flue gas desulfurization (FGD system, as well as investigation of mercury content in the combustion products, i.e. fly ash, slag, FGD product (gypsum and FGD effluents (waste. Within the framework of the present study the concentration of mercury vapor in the exhaust gas was also investigated. The analysis was performed using Lumex RA-915+ spectrometer with an attachment (RP-91C. The measurements were carried out at three locations, i.e. before the electrostatic precipitator (ESP, downstream the ESP, and downstream the wet FGD plant. Design of the measurement system allowed to determine both forms of mercury in the flue gas (Hg0 and Hg2+ at all measurement locations.Based on the measurement results the balance of mercury for a pulverized coal (PC boiler was calculated and the amount of mercury was assessed both in the input solids (fuel and sorbent, as well as the gaseous and solids products (flue gas, slag, ash, gypsum and FGD waste.

  4. Mitigation of caustic stress corrosion cracking of steam generator tube materials by blowdown -a case study

    International Nuclear Information System (INIS)

    Dutta, Anu; Patwegar, I.A.; Chaki, S.K.; Venkat Raj, V.

    2000-01-01

    The vertical U-tube steam generators are among the most important equipment in nuclear power plants as they form the vital link between the reactor and the turbogenerator. Over ∼ 35 years of operating experience of water cooled reactor has demonstrated that steam generator tubes are susceptible to various forms of degradation. This degradation leads to failure and outages of the power plant. A majority of these failures have been attributed to concentrated alkali attacks in the low flow areas such as crevices in the tube to tube sheet joints, baffle plate location and the areas of sludge deposits. Free hydroxides can be produced by improper maintenance of phosphate chemical control in the secondary side of the steam generators and also by the thermal decomposition of impurities present in the condenser cooling water which may leak into the feed water through the condenser tubes. The free hydroxides concentrate in the low flow areas. This buildup of free hydroxide in combination with residual stress leads to caustic stress corrosion cracking. In order to mitigate caustic stress corrosion cracking of Inconel 600 tubes, the trend is to avoid phosphate dosing. Instead All Volatile Treatment (AVT) for secondary water is used backed by full flow condensate polishing. Sodium hydroxide concentration is now being considered as the basis for steam generator blowdown. A methodology has been established for determining the blowdown requirement in order to mitigate caustic stress corrosion cracking in the secondary side of the vertical U-tube natural circulation steam generator. A case study has been carried out for zero solid treatment (AVT coupled with full flow condensate polishing plant) water chemistry. Only continuous blowdown schemes have been studied based on maximum caustic concentration permissible in the secondary side of the steam generator. The methodology established can also be used for deciding concentration of any other impurities

  5. Borel hierarchies in infinite products of Polish spaces

    Indian Academy of Sciences (India)

    with two product topologies: (i) the product of copies of the Polish topology on X, so that H is again a Polish space and (ii) the product of copies of the discrete topology on X. Define now the Borel hierarchy in the larger topology on H. To do so, we need some notation. An element of H will be denoted by h = (x1,x2,...,xn,.

  6. Polishing Sapphire Substrates by 355 nm Ultraviolet Laser

    Directory of Open Access Journals (Sweden)

    X. Wei

    2012-01-01

    Full Text Available This paper tries to investigate a novel polishing technology with high efficiency and nice surface quality for sapphire crystal that has high hardness, wear resistance, and chemical stability. A Q-switched 355 nm ultraviolet laser with nanosecond pulses was set up and used to polish sapphire substrate in different conditions in this paper. Surface roughness Ra of polished sapphire was measured with surface profiler, and the surface topography was observed with scanning electronic microscope. The effects of processing parameters as laser energy, pulse repetition rate, scanning speed, incident angle, scanning patterns, and initial surface conditions on surface roughness were analyzed.

  7. Effect of One-Step and Multi-Steps Polishing System on Enamel Roughness

    Directory of Open Access Journals (Sweden)

    Cynthia Sumali

    2013-07-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 The final procedures of orthodontic treatment are bracket debonding and cleaning the remaining adhesive. Multi-step polishing system is the most common method used. The disadvantage of that system is long working time, because of the stages that should be done. Therefore, dental material manufacturer make an improvement to the system, to reduce several stages into one stage only. This new system is known as one-step polishing system. Objective: To compare the effect of one-step and multi-step polishing system on enamel roughness after orthodontic bracket debonding. Methods: Randomized control trial was conducted included twenty-eight maxillary premolar randomized into two polishing system; one-step OptraPol (Ivoclar, Vivadent and multi-step AstroPol (Ivoclar, Vivadent. After bracket debonding, the remaining adhesive on each group was cleaned by subjective polishing system for ninety seconds using low speed handpiece. The enamel roughness was subjected to profilometer, registering two roughness parameters (Ra, Rz. Independent t-test was used to analyze the mean score of enamel roughness in each group. Results: There was no significant difference of enamel roughness between one-step and multi-step polishing system (p>0.005. Conclusion: One-step polishing system can produce a similar enamel roughness to multi-step polishing system after bracket debonding and adhesive cleaning.DOI: 10.14693/jdi.v19i3.136

  8. Nucleation and capture of condensible airborne contaminants in an aqueous scrubbing system

    International Nuclear Information System (INIS)

    Postma, A.K.; Hilliard, R.K.

    1978-09-01

    The fate of condensible contaminants in an aqueous scrubbing system was evaluated. Knowledge of the behavior of volatile fission product compounds is important in evaluating the effectiveness of emergency air cleaning systems proposed for use in containment systems of breeder reactor plants. When a high temperature air stream passes through a spray quench chamber, very large cooling rates occur in the drop boundary layers. These large cooling rates cause large supersaturations in airborne concentrations of condensible contaminants, and one predicts that most condensation would take place through homogeneous nucleation. The very small particles formed would agglomerate, and attach to sodium aerosol particles which would be present. In the study the overall removal efficiency of volatile fission product species (typified by NaI, SeO 2 , and Sb 2 O 3 ) in an air cleaning train (quench chamber, venturi scrubber, and fibrous bed) was theoretically evaluated. The overall removal efficiency of condensible materials was found to be lower than that for sodium compound aerosols because the freshly condensed particles would be smaller in size. For a base case, a removal efficiency of 99.97 percent was predicted for condensible materials. The fibrous bed scrubber exhibited superior particle removal characteristics for small particles compared to the quench chamber and venturi scrubber. Its removal efficiency exceeded 97 percent for even the most penetrating particle size (about 0.4 micron aerodynamic diameter). Therefore, all condensible fission products would be removed with efficiencies exceeding 97 percent

  9. The View of Lithuanian Statehood Held by the Polish Underground during 1939-1944

    OpenAIRE

    Bubnys, Arūnas

    2006-01-01

    The article investigates the attitudes of Polish underground actors towards the statehood of Lithuania, its territorial integrity, and Lithuanian-Polish relations during the World War II. The author draws the conclusion that Polish underground political structures expressed a hostile and prejudiced attitude towards Lithuania. All the blame and responsibility for bad mutual relations is put on Lithuania and Lithuanians. Polish underground actors living in Vilnija were extremely hostile towards...

  10. A parametric study of condensation-induced water hammer in nuclear power plants

    International Nuclear Information System (INIS)

    Shon, Young Uk; Chun, Moon Hyun

    1990-01-01

    Condensation-induced water hammer (CIWH), which may occur in systems involving steam and water simultaneously, has a series of processes such as formation of water slug, trapping a steam cavity, depressurization due to steam condensation, accelerating slug caused pressure difference over it and final slug impact. These processes are dependent on water flow rate in a pipe, water temperature, water subcooling, steam pressure, size of slug and cavity, and heat transfer coefficient at interface between steam and water. In the present work, the prediction of conditions to initiate water hammer has been made with full scale by applying the open channel flow theory. These conditions are expressed in terms of water flow rate according to changes of steam pressure, water subcooling, and pipe diameter. Under these conditions that induce CIWH, the effect of parameters which influence on slug impact pressure and cavity collapse rate have been studied with full scale. Also, the impact loads that may be applied to piping design were evaluated under various system conditions

  11. Experimental Study on Layered Ice Bonded Abrasive Polishing of Glass-ceramics

    Directory of Open Access Journals (Sweden)

    Yuli SUN

    2014-12-01

    Full Text Available Layered ice bonded abrasive tools (LIBAT is a new kind of one which not only has the ability of lapping and polishing but also has the effect of self-dressing. In this paper, two kinds of layered ice bonded abrasive tools were designed and manufactured. Experimental studies on layered ice bonded abrasive (LIBA polishing of glass-ceramics were conducted. The results show that the surface topography of glass-ceramics polished by micro α-Al2O3-nano α-Al2O3 LIBAT is better than that of polished by micro α-Al2O3-nano SiO2 LIBAT. The surface roughness Sa of glass-ceramics polished by the two kinds of LIBAT is at the nanometer scale. The reasons of this phenomenon were analyzed. The experimental results illustrate that the LIBAT shows good effect and can be used in production practice. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.6149

  12. Energy savings in Polish buildings

    Energy Technology Data Exchange (ETDEWEB)

    Markel, L.C.; Gula, A.; Reeves, G.

    1995-12-31

    A demonstration of low-cost insulation and weatherization techniques was a part of phase 1 of the Krakow Clean Fossil Fuels and Energy Efficient Project. The objectives were to identify a cost-effective set of measures to reduce energy used for space heating, determine how much energy could be saved, and foster widespread implementation of those measures. The demonstration project focused on 4 11-story buildings in a Krakow housing cooperative. Energy savings of over 20% were obtained. Most important, the procedures and materials implemented in the demonstration project have been adapted to Polish conditions and applied to other housing cooperatives, schools, and hospitals. Additional projects are being planned, in Krakow and other cities, under the direction of FEWE-Krakow, the Polish Energie Cities Network, and Biuro Rozwoju Krakowa.

  13. Nd:YOV4 laser polishing on WC-Co HVOF coating

    Science.gov (United States)

    Giorleo, L.; Ceretti, E.; Montesano, L.; La Vecchia, G. M.

    2017-10-01

    WC/Co coatings are widely applied to different types of components due to their extraordinary performance properties including high hardness and wear properties. In industrial applications High Velocity Oxy-Fuel (HVOF) technique is extensively used to deposit hard metal coatings. The main advantage of HVOF compared to other thermal spray techniques is the ability to accelerate the melted powder particles of the feedstock material at a relatively high velocity, leading to obtain good adhesion and low porosity level. However, despite the mentioned benefits, the surface finish quality of WC-Co HVOF coatings results to be poor (Ra higher than 5 µm) thus a mechanical polishing process is often needed. The main problem is that the high hardness of coating leads the polishing process expensive in terms of time and tool wear; moreover polishing becomes difficult and not always possible in case of limited accessibility of a part, micro dimensions or undercuts. Nowadays a different technique available to improve surface roughness is the laser polishing process. The polishing principle is based on focused radiation of a laser beam that melts a microscopic layer of surface material. Compared to conventional polishing process (as grinding) it ensures the possibility of avoiding tool wear, less pollution (no abrasive or liquids), no debris, less machining time and coupled with a galvo system it results to be more suitable in case of 3D complex workpieces. In this paper laser polishing process executed with a Nd:YOV4 Laser was investigated: the effect of different process parameters as initial coating morphology, laser scan speed and loop cycles were tested. Results were compared by a statistical approach in terms of average roughness along with a morphological analysis carried out by Scanning Electron Microscope (SEM) investigation coupled with EDS spectra.

  14. Experimental Study on Abrasive Waterjet Polishing of Hydraulic Turbine Blades

    International Nuclear Information System (INIS)

    Khakpour, H; Birglenl, L; Tahan, A; Paquet, F

    2014-01-01

    In this paper, an experimental investigation is implemented on the abrasive waterjet polishing technique to evaluate its capability in polishing of surfaces and edges of hydraulic turbine blades. For this, the properties of this method are studied and the main parameters affecting its performance are determined. Then, an experimental test-rig is designed, manufactured and tested to be used in this study. This test-rig can be used to polish linear and planar areas on the surface of the desired workpieces. Considering the number of parameters and their levels, the Taguchi method is used to design the preliminary experiments. All experiments are then implemented according to the Taguchi L 18 orthogonal array. The signal-to-noise ratios obtained from the results of these experiments are used to determine the importance of the controlled polishing parameters on the final quality of the polished surface. The evaluations on these ratios reveal that the nozzle angle and the nozzle diameter have the most important impact on the results. The outcomes of these experiments can be used as a basis to design a more precise set of experiments in which the optimal values of each parameter can be estimated

  15. Environmental impact of condenser effluents into coastal marine environments: need for continuous monitoring

    International Nuclear Information System (INIS)

    Venugopal, V.P.

    2015-01-01

    Electric plants working on the principle of steam-water cycle require large amounts of water for condenser cooling purpose. Nuclear power plants require, on an average, about 3m 3 cooling water per minute per megawatt of electricity generated. Owning to the scarcity of large sources of freshwater for cooling, newer power plants, particularly in water-stressed parts of the world, tend to get located in coastal regions, where they can make use of the abundant seawater. However, this also poses a problem, in terms of the biofouling potential of coastal marine environments. Sessile benthic organism, which are generally present as part of the coastal marine ecosystem, extend their habitat into the cooling water system of the power plant. It is often observed that massive growth of such fouling organisms may endanger normal operation of the cooling water system, unless appropriate control measures are adopted. Presence of calcareous organisms such as mussels and barnacles in the pre-condenser sections of the power plant is a common sight; but these organisms, when lodged inside condenser tubes, can not only reduce the heat transfer efficiency but also can cause localized corrosion and tube leakage, leading of ingress of seawater into the steam-water system. It is, therefore, important that appropriate control measures are adopted to discourage the growth of the organisms. However, this needs to be done in an environmentally sustainable manner, as the cooling water is ultimately discharged back into the sea. The presentation aims to give and overview of the biofouling problems generally encountered in a typical tropical coastal power station operating in India and the chemical control measures adopted and their effectiveness. The talk also throws light on the more recent advances in biofouling control such as surface modification and use of nanotechnology which, in the foreseeable future, may provide more lasting and environmentally sustainable solutions. (author)

  16. Calculation and simulation on mid-spatial frequency error in continuous polishing

    International Nuclear Information System (INIS)

    Xie Lei; Zhang Yunfan; You Yunfeng; Ma Ping; Liu Yibin; Yan Dingyao

    2013-01-01

    Based on theoretical model of continuous polishing, the influence of processing parameters on the polishing result was discussed. Possible causes of mid-spatial frequency error in the process were analyzed. The simulation results demonstrated that the low spatial frequency error was mainly caused by large rotating ratio. The mid-spatial frequency error would decrease as the low spatial frequency error became lower. The regular groove shape was the primary reason of the mid-spatial frequency error. When irregular and fitful grooves were adopted, the mid-spatial frequency error could be lessened. Moreover, the workpiece swing could make the polishing process more uniform and reduce the mid-spatial frequency error caused by the fix-eccentric plane polishing. (authors)

  17. Effects of non-condensable gas on the condensation of steam

    International Nuclear Information System (INIS)

    Jackson, J.D.; An, P.; Reinert, A.; Ahmadinejad, M.

    2000-01-01

    The experimental work reported here was undertaken with the aim of extending the database currently available on the condensation of steam in the presence of non-condensable gases and thereby improving the empirical input to thermal-hydraulic codes which might be used for design and safety assessment of advanced water-cooled nuclear reactors. Heat was removed from flowing mixtures of steam and air in a test section by means of a water-cooled condensing plate. The test facility constructed for the study incorporates a degassing unit which supplies water to a boiler. This delivers steam steadily to a mixing chamber where it joins with a flow of preheated air. The mixture of steam and air is supplied to the bottom of a cylindrical test section in which it flows upwards over a double sided condensing plate which can be vertical, inclined or horizontal, The rate at which heat is removed by cooling water flowing through internal passages in the plate can de determined calorimetrically knowing the flow rate of the water and its temperature rise. After commissioning experiments had shown that reliable measurements of condensation heat transfer rate could be made using the test facility, a programme of development work followed in the course of which three different designs of condensing plate were evaluated in turn. The version eventually used in the main programme of experiments which followed was made from copper. However, its surfaces were coated with a thin layer of nickel and then with one of chromium. It was found that such a surface consistently promoted dropwise condensation and showed no signs of deterioration after lengthy periods of use. The rate of heat removal from pure steam and from mixtures of steam and air in varying proportions was measured as a function of plate sub-cooling for a variety of plate orientations. (author)

  18. Numerical analysis of transient pressure variation in the condenser of a nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xinjun; Zhou, Zijie; Song, Zhao [Xi' an Jiaotong University, Xi' an (China); Lu, Qiankui; Li, Jiafu [Dong Fang Turbine Co., Ltd, Deyang (China)

    2016-02-15

    To research the characteristics of the transient variation of pressure in a nuclear power station condenser under accident condition, a mathematical model was established which simulated the cycling cooling water, heat transfer and pressure in the condenser. The calculation program of transient variation characteristics was established in Fortran language. The pump's parameter, cooling line's organization, check valve's feature and the parameter of siphonic water-collecting well are involved in the cooling water flow's mathematical model. The initial conditions of control volume are determined by the steady state of the condenser. The transient characteristics of a 1000 MW nuclear power station's condenser and cooling water system were examined. The results show that at the condition of plant-power suspension of pump, the cooling water flow rate decreases rapidly and refluxes, then fluctuates to 0. The variation of heat transfer coefficient in the condenser has three stages: at start it decreases sharply, then increases and decreases, and keeps constant in the end. Under three conditions (design, water and summer), the condenser pressure goes up in fluctuation. The time intervals between condenser's pressure signals under three conditions are about 26.4 s, which can fulfill the requirement for safe operation of nuclear power station.

  19. Surface morphology changes of acrylic resins during finishing and polishing phases

    Directory of Open Access Journals (Sweden)

    Glaucio Serra

    2013-12-01

    Full Text Available INTRODUCTION: The finishing and polishing phases are essential to improve smoothness and shining on the surface of acrylic resins used to make removable orthodontic appliances. A good surface finishing reduces roughness, which facilitates hygiene, prevents staining and provides greater comfort to the patients. OBJECTIVE: The aim of this paper was to analyze the changes on surface morphology of acrylic resins during finishing and polishing phases. METHODS: Thirty discs (10 mm in diameter and 5 mm in length were made with acrylic resin and randomly divided into ten groups. The control group did not receive any treatment while the other groups received gradual finishing and polishing. The last group received the entire finishing and polishing procedures. Surface morphology was qualitatively analyzed through scanning electron microscopy and quantitatively analyzed through a laser profilometer test. RESULTS: The acrylic resin surfaces without treatment showed bubbles which were not observed in the subsequent phases. Wearing out with multilaminated burs, finishing with wood sandpaper and finishing with water sandpaper resulted in surfaces with decreasing irregularities. The surfaces that were polished with pumice and with low abrasive liquids showed high superficial smoothness. CONCLUSION: Highly smooth acrylic resin surfaces can be obtained after mechanical finishing and polishing performed with multilaminated burs, wood sandpaper, water sandpaper, pumice and low abrasive liquids.

  20. Purification method for condensate

    International Nuclear Information System (INIS)

    Shimoda, Akiyoshi.

    1996-01-01

    Condensates generated in secondary coolant circuits of a PWR type reactor are filtered using a hollow thread separation membranes comprising aromatic polyether ketone. Preferably, condensates after passing through a turbine are filtered at a place between a condensator and a steam generator at high temperature as close as a temperature of the steam generator. As the hollow thread membrane, partially crystalline membrane comprising aromatic polyether ketone is used. When it is used at high temperature, the crystallinity is preferably not less than 15wt%. Since a hollow thread membrane comprising the aromatic polyether ketone of excellent heat resistance is used, it can filter and purify the condensates at not lower than 70degC. Accordingly, impurities such as colloidal iron can be removed from the condensates, and the precipitation of cruds in the condensates to a steam generator and a turbine can be suppressed. (I.N.)

  1. NUCLEAR POWER PLANT

    Science.gov (United States)

    Carter, J.C.; Armstrong, R.H.; Janicke, M.J.

    1963-05-14

    A nuclear power plant for use in an airless environment or other environment in which cooling is difficult is described. The power plant includes a boiling mercury reactor, a mercury--vapor turbine in direct cycle therewith, and a radiator for condensing mercury vapor. (AEC)

  2. In-service inspection of condenser tubes by means of electrochemical methods

    International Nuclear Information System (INIS)

    Taelemans, G.

    The commissioning of an increasing number of large nuclear power plants involves an increased significance of such condenser tube problems as: - erosion on tube ends, - generalized corrosion and pitting corrosion, - deposits in the tubes. In order to solve such problems, investigations were performed especially focused on a measurement technique that enables in-service behaviour of condenser tubes to be monitored. For such a purpose, measurement of the polarization resistance has been adopted. The existing corrosion products and scaled-off iron oxides were eliminated by means of a carborundum balls processing, as clearly appears from polarization resistance reduction. Then iron sulphate was injected in order to build a new and better protective layer. In addition, the tube was kept clean by means of foam rubber balls. There is a second implementation area: fouled condenser tubes. A significant polarization resistance reduction is noted during the acid cleaning. (orig.) [de

  3. Implementation of the Bulgarian-Polish online dictionary

    Directory of Open Access Journals (Sweden)

    Ludmila Dimitrova

    2015-11-01

    Full Text Available Implementation of the Bulgarian-Polish online dictionary The paper describes the implementation of an online Bulgarian-Polish dictionary as a technological tool for applications in digital humanities. This bilingual digital dictionary is developed in the frame of the joint research project “Semantics and Contrastive Linguistics with a focus on a bilingual electronic dictionary” between IMI-BAS and ISS-PAS, supervised by L. Dimitrova (IMI-BAS and V. Koseska-Toszewa (ISS-PAS. In addition, the main software tools for web-presentation of the dictionary are described briefly.

  4. Condensation front modelling in a moisture separator reheater by application of SICLE numerical model

    International Nuclear Information System (INIS)

    Grange, J.L.; Caremoli, C.; Eddi, M.

    1988-01-01

    This paper presents improvements performed on SICLE numerical model in order to analyse the condensation front that occurs in the moisture separator reheaters (MSR) of nuclear power plants. Modifications of SICLE numerical model architecture and a fine modelling of reheater have allowed to correctly simulate the MSR thermohydraulic behaviour during a severe transient (plant islanding) [fr

  5. Lay beliefs on Polish oncology in the evaluation of healthy individuals.

    Science.gov (United States)

    Synowiec-Piłat, Małgorzata

    2017-12-23

    Poland is among the countries which reported the highest rates of mortality from cancer. The health behaviours of people are influenced, among other things, by their beliefs about cancer, but their evaluation of oncological institutions and specialists seems also to be of great importance. Objectives. 1. How the respondents evaluate Polish oncology: a) the conditions of treatment in oncology hospitals, b) access to oncological medical services, c) the competence of oncologists. 2. What are the socio-cultural factors of the assessment of Polish oncology? 3. What is the influence of the grade level of the assessment of Polish oncology on the degree of fear and the knowledge about cancer? The study was carried out with a sample of 910 adult residents of Wroclaw in south-west Poland. Quota sampling was used. An interview questionnaire was used as the method. Analysis of the data showed a negative image of Polish oncology, according to the study participants: dissatisfaction with both treatment conditions and with access to medical services. Assessment of Polish oncology depends primarily on education, age and economic situation, as well as 'family history of cancer', and attitude towards doctors. The lower the rating of Polish oncology, the lower the medical knowledge, and the higher the level of fear of cancer. Negative assessment of Polish oncology perpetuates the fear of cancer in society. There is a need for constant improvement of the quality of medical oncology services, for building public trust in physicians, to fight inequalities in health, and to take into account the lay perspectives in developing strategies to combat cancer.

  6. Prediction of Heat Removal Capacity of Horizontal Condensation Heat Exchanger submerged in Pool

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Seong-Su; Hong, Soon-Joon [FNC Tech., Yongin (Korea, Republic of); Cho, Hyoung-Kyu [Seoul National University, Seoul (Korea, Republic of); Park, Goon-Cherl [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2014-10-15

    As representative passive safety systems, there are the passive containment cooling system (PCCS) of ESBWR, the emergency condenser system (ECS) of the SWR-1000, the passive auxiliary feed-water system (PAFS) of the APR+ and etc. During the nuclear power plant accidents, these passive safety systems can cool the nuclear system effectively via the heat transfer through the steam condensation, and then mitigate the accidents. For the optimum design and the safety analysis of the passive safety system, it is essential to predict the heat removal capacity of the heat exchanger well. The heat removal capacity of the horizontal condensation heat exchanger submerged in a pool is determined by a combination of a horizontal in-tube condensation heat transfer and a boiling heat transfer on the horizontal tube. Since most correlations proposed in the previous nuclear engineering field were developed for the vertical tube, there is a certain limit to apply these correlations to the horizontal tube. Therefore, this study developed the heat transfer model for the horizontal Ushaped condensation heat exchanger submerged in a pool to predict well the horizontal in-tube condensation heat transfer, the boiling heat transfer on the horizontal tube and the overall heat removal capacity of the heat exchanger using the best-estimate system analysis code, MARS.

  7. The Profile of a Polish Mutual Fund Manager

    Directory of Open Access Journals (Sweden)

    Dariusz Filip

    2018-05-01

    Full Text Available Aim/purpose - The purpose of this paper is to identify the characteristics that are typical of mutual fund managers. Design/methodology/approach - The study concentrates on a set of socio-demographic data, such as: age, gender, education, experience, and professional qualifications of 336 portfolio managers. The applied research strategy relies on an analysis concerning a set of statistical metrics describing the population under examination. Findings - The average Polish fund manager is a 37-year-old man, a holder of a stock-broker or investment adviser license. He obtained the authorization from the Polish Financial Supervision Authority (KNF a few years after graduating from the Warsaw School of Economics (SGH. He has 11 years' experience in financial markets and 7 years' experience in the mutual fund industry. Research implications/limitations - The identification of managerial characteristics for the purpose of creating a profile of a Polish mutual fund manager will provide an important basis for further surveys and analyses aimed to evaluate the effectiveness of mutual funds. Originality/value/contribution - There are no investigations within the discussed area in Polish studies. Therefore, the identification of the characteristics that are typical of mutual fund managers will make a contribution to the finance literature.(original abstract

  8. Simple Simulations of DNA Condensation

    Energy Technology Data Exchange (ETDEWEB)

    STEVENS,MARK J.

    2000-07-12

    Molecular dynamics simulations of a simple, bead-spring model of semiflexible polyelectrolytes such as DNA are performed. All charges are explicitly treated. Starting from extended, noncondensed conformations, condensed structures form in the simulations with tetravalent or trivalent counterions. No condensates form or are stable for divalent counterions. The mechanism by which condensates form is described. Briefly, condensation occurs because electrostatic interactions dominate entropy, and the favored Coulombic structure is a charge ordered state. Condensation is a generic phenomena and occurs for a variety of polyelectrolyte parameters. Toroids and rods are the condensate structures. Toroids form preferentially when the molecular stiffness is sufficiently strong.

  9. [Lysenkoism in Polish botany].

    Science.gov (United States)

    Köhler, Piotr

    2008-01-01

    Lysenkoism in Poland was never an autonomous phenomenon. The whole array of reasons for which it appeared in Polish science would require a separate study--here it only needs to be pointed out that the major reasons included terror on the part of the security service, lawlessness, the ubiquitous atmosphere of intimidation and terror, censorship, the diminishing sphere of civil liberties, political show trials, propaganda and denunciations. An important role in facilitating the introduction of Lysenkoism was played also by the reorganization of science after World War Two, the isolation of Polish science from science in the West, as well as the damage it had suffered during the war. At first, Lysenkoism was promoted in Poland by a small group of enthusiastic and uncritical proponents. A overview of the events connected with the ten years of Lysenkoism in Poland (end of 1948--beginning of 1958) shows a two-tier picture of how the 'idea' was propagated. The first tier consisted in the activities of the Association of Marxist Naturalists [Koło Przyrodników-Marksistów], which it engaged in since the end of 1948. The Association was later transformed into a Union of Marxist Naturalists, and this in turn merged, in 1952, with the Copernican Society of Polish Naturalists [Polskie Towarzystwo Przyrodników im. Kopernika]. It was that society which promoted Lysenkoism longest, until the end of 1956. The propaganda and training activities of the circle and the society prepared ground for analogous activities of the newly formed Polish Academy of Science (PAN), which--since its very establishment in 1952--engaged in promoting Lysenkoism through its Second Division. These activities were aimed at naturalists, initially at those who were prominent scientists (eg. the conference at Kuźnice, 1950/1951), and then at those who were only starting their academic career (including national courses in new biology at Dziwnów, 1952, or Kortowo, 1953 and 1955). The end to promoting

  10. Wildfire Activity Across the Triassic-Jurassic Boundary in the Polish Basin: Evidence from New Fossil Charcoal & Carbon-isotope Data

    Science.gov (United States)

    Pointer, R.; Belcher, C.; Hesselbo, S. P.; Hodbod, M.; Pieńkowski, G.

    2017-12-01

    New fossil charcoal abundance and carbon-isotope data from two sedimentary cores provide new evidence of extreme environmental conditions in the Polish Basin during the Latest Triassic to Earliest Jurassic. Sedimentary cores from the Polish Basin provide an excellent record of terrestrial environmental conditions across the Triassic-Jurassic Boundary, a time of climatic extremes. Previous work has shown that the marine realm was affected by a large perturbation to the carbon cycle across the Triassic-Jurassic Boundary (manifested by large negative and positive carbon-isotope excursions) and limited records of charcoal abundance and organic geochemistry have indicated important changes in fire regime in the coeval ecosystems. Here we present two new carbon-isotope records generated from fossil plant matter across the Triassic-Jurassic boundary, and present new charcoal records. The charcoal abundance data confirm that there was variation in wildfire activity during the Late Triassic-Early Jurassic in the Polish Basin. Peaks in the number of fossil charcoal fragments present occur in both sedimentary cores, and increases in fossil charcoal abundance are linked to wildfires, signalling a short-lived rise in wildfire activity. Fossil charcoal abundance does not appear to be fully controlled by total organic matter content, depositional environment or bioturbation. We argue that increased wildfire activity is likely caused by an increase in ignition of plant material as a result of an elevated number of lightning strikes. Global warming (caused by a massive input of carbon into the atmosphere, as indicated by carbon-isotope data) can increase storm activity, leading to increased numbers of lightning strikes. Previous Triassic-Jurassic Boundary wildfire studies have found fossil charcoal abundance peaks at other northern hemisphere sites (Denmark & Greenland), and concluded that they represent increases in wildfire activity in the earliest Jurassic. Our new charcoal and

  11. Mechanistic, kinetic, and processing aspects of tungsten chemical mechanical polishing

    Science.gov (United States)

    Stein, David

    This dissertation presents an investigation into tungsten chemical mechanical polishing (CMP). CMP is the industrially predominant unit operation that removes excess tungsten after non-selective chemical vapor deposition (CVD) during sub-micron integrated circuit (IC) manufacture. This work explores the CMP process from process engineering and fundamental mechanistic perspectives. The process engineering study optimized an existing CMP process to address issues of polish pad and wafer carrier life. Polish rates, post-CMP metrology of patterned wafers, electrical test data, and synergy with a thermal endpoint technique were used to determine the optimal process. The oxidation rate of tungsten during CMP is significantly lower than the removal rate under identical conditions. Tungsten polished without inhibition during cathodic potentiostatic control. Hertzian indenter model calculations preclude colloids of the size used in tungsten CMP slurries from indenting the tungsten surface. AFM surface topography maps and TEM images of post-CMP tungsten do not show evidence of plow marks or intergranular fracture. Polish rate is dependent on potassium iodate concentration; process temperature is not. The colloid species significantly affects the polish rate and process temperature. Process temperature is not a predictor of polish rate. A process energy balance indicates that the process temperature is predominantly due to shaft work, and that any heat of reaction evolved during the CMP process is negligible. Friction and adhesion between alumina and tungsten were studied using modified AFM techniques. Friction was constant with potassium iodate concentration, but varied with applied pressure. This corroborates the results from the energy balance. Adhesion between the alumina and the tungsten was proportional to the potassium iodate concentration. A heuristic mechanism, which captures the relationship between polish rate, pressure, velocity, and slurry chemistry, is presented

  12. Feasibility study on the guided wave technique for condenser tube in NPP

    International Nuclear Information System (INIS)

    Choi, Sung Nam; Kim, Young Ho; Kim, Hyung Nam; Yoo, Hyun Joo; Hwang, W. G.

    2004-01-01

    The condenser tube is examined by the eddy current test (ECT) method to identify the integrity of the nuclear power plant. Because ECT probe is moved through the tube inside to identify flaws, the ECT probe should be exchanged periodically due to the wear of probe surface in order to remove the noise form the ECT signal. Moreover, it is impossible to examine the tube by ECT method because the ECT probe can not move through the inside due to the deformation such as dent. Recently, the theory of guided wave was established and the equipment applying the theory has been actively developed so as to overcome the limitation of ECT method for the tube inspection of heater exchanger in nuclear power plant. The object of this study is to know the feasibility of applying the guided wave technique to condenser tube in NPP

  13. Condensation shocks in high momentum two-phase flows in condensing injectors

    International Nuclear Information System (INIS)

    Anand, G.; Christensen, R.N.

    1993-01-01

    This study presents a phenomenological and mathematical model of condensation shocks in high momentum two-phase flows in condensing injectors. The characteristics of the shock were related to the mode of vapor bubble collapse. Using cavitation terminology, the bubble collapse can be classified as inertially controlled or thermally controlled. Inertial bubble collapse occurs rapidly whereas, a thermally controlled collapse results in a significantly longer collapse time. The interdependence between the bubble collapse mode and the momentum and pressure of the flow, was analyzed in this study. For low-temperature-high-velocity flows a steep pressure rise with complete condensation was obtained. For a high-temperature-low velocity flow with noncondensables, low pressure recovery with incomplete condensation was observed. These trends are in agreement with previous experimental observations

  14. Chemical Mechanical Polishing of Ruthenium, Cobalt, and Black Diamond Films

    Science.gov (United States)

    Peethala, Brown Cornelius

    Ta/TaN bilayer serves as the diffusion barrier as well as the adhesion promoter between Cu and the dielectric in 32 nm technology devices. A key concern of future technology devices (layer (vs. a bilayer of Ta/TaN) to act as a barrier. During patterning, they need to be planarized using conventional chemical mechanical polishing (CMP) to achieve a planar surface. However, CMP of these new barrier materials requires novel slurry compositions that provide adequate selectivity towards Cu and dielectric films, and minimize galvanic corrosion. Apart from the application as a barrier, Ru also has been proposed as a lower electrode material in metal-insulator-metal capacitors where high (> 50 nm/min) Ru removal rates (RRs) are required and as a stop layer in magnetic recording head fabrication where low (hydroxide (KOH). It was also determined that increased the ionic strength is not responsible for the observed increase in Ru removal rate. Benzotirazole (BTA) and ascorbic acid were added to the slurry to reduce the open circuit potential (Eoc) difference between Cu and Ru to ˜20 mV from about 550 mV in the absence of additives. A removal mechanism with KIO4 as the oxidizing agent is proposed based on the formation of several ruthenium oxides, some of which formed residues on the polishing pad below a pH of ˜7. Next, a colloidal silica-based slurry with hydrogen peroxide (H 2O2) as the oxidizer (1 wt%), and arginine (0.5 wt%) as the complexing agent was developed to polish Co at pH 10. The Eoc between Cu and Co at the above conditions was reduced to ˜20 mV compared to ˜250 mV in the absence of additives, suggestive of reduced galvanic corrosion during the Co polishing. The slurry also has the advantages of good post-polish surface quality at pH 10, and no dissolution rate. BTA at a concentration of 5mM in this slurry inhibited Cu dissolution rates and yielded a Cu/Co RR ratio of ˜0.8:1 while the open potential difference between Cu and Co was further reduced to ˜10

  15. Condensation in complex geometries

    International Nuclear Information System (INIS)

    Lauro, F.

    1975-01-01

    A mathematical evaluation of the condensation exchange coefficient can only succeds for well specified cases: small upright or inclined plates, horizontal tubes, small height vertical tubes. Among the main hypotheses accounted for this mathematical development in the case of the condensate, a laminar flow and uniform surface temperature are always considered. In practice certain shapes of surfaces significantly increase the heat transfer during the vapor condensation on a surface wet by the condensate. Such surfaces are rough surfaces such as the condensate is submitted to surface tension effects, negligeable for plane or large curvature surfaces, and the nature of the material may play an important role (temperature gradients). Results from tests on tubes with special shapes, performed in France or out of France, are given [fr

  16. Condensate demineralizer system for Fukushima Daiichi Nuclear Power Station, the Tokyo Electric Power Co., Inc

    International Nuclear Information System (INIS)

    Ariyoshi, Shigeki; Ikeda, Yukio; Kuramoto, Kenji; Omori, Yoshi; Yamamoto, Hiroyoshi

    1975-01-01

    This paper describes the condensate demineralizing equipment recently supplied to the second, third, and fifth power units of the Fukushima Daiichi Nuclear Power Station of the Tokyo Electric Power Company, Inc. The output of this equipment is rated as 4,900 m 3 /h each, which is currently the largest capacity for this type of equipment in Japan. The purpose of this equipment is to remove any ion components and suspended solids contained in condensate to improve its water purity. By doing so, decreasing the corrosion rate of materials used in the plant and, at the same time, decreasing the radioactivity of the condensate, thus easing the whole plant operation can be achieved. The same kind of equipment is also employed at the conventional thermal power stations, but the required functioning and operating mode are quite different. In the case of the nuclear power plant, extremely severe requirements specific with nuclear technology must be met which arise solely from dealing with radioactive substances. Not only the water treatment method, but also layout and arrangement, operation and liquid waste processing methods differ from those for the conventional power plants. The equipment for the sixth unit at Fukushima is now under designing and that for the Tokai No.2 unit of the Japan Atomic Power Company is already under shop fabrication. Both have the rated capacity of 7,300 m 3 /h each, which exceeds far up the capacity of the previously mentioned equipment. (auth.)

  17. Sedimentary condensation and authigenesis

    Science.gov (United States)

    Föllmi, Karl

    2016-04-01

    Most marine authigenic minerals form in sediments, which are subjected to condensation. Condensation processes lead to the formation of well individualized, extremely thin ( 100ky), and which experienced authigenesis and the precipitation of glaucony, verdine, phosphate, iron and manganese oxyhydroxides, iron sulfide, carbonate and/or silica. They usually show complex internal stratigraphies, which result from an interplay of sediment accumulation, halts in sedimentation, sediment winnowing, erosion, reworking and bypass. They may include amalgamated faunas of different origin and age. Hardgrounds may be part of condensed beds and may embody strongly condensed beds by themselves. Sedimentary condensation is the result of a hydrodynamically active depositional regime, in which sediment accumulation, winnowing, erosion, reworking and bypass are processes, which alternate as a function of changes in the location and intensity of currents, and/or as the result of episodic high-energy events engendered by storms and gravity flow. Sedimentary condensation has been and still is a widespread phenomenon in past and present-day oceans. The present-day distribution of glaucony and verdine-rich sediments on shelves and upper slopes, phosphate-rich sediments and phosphorite on outer shelves and upper slopes, ferromanganese crusts on slopes, seamounts and submarine plateaus, and ferromanganese nodules on abyssal seafloors is a good indication of the importance of condensation processes today. In the past, we may add the occurrence of oolitic ironstone, carbonate hardgrounds, and eventually also silica layers in banded iron formations as indicators of the importance of condensation processes. Besides their economic value, condensed sediments are useful both as a carrier of geochemical proxies of paleoceanographic and paleoenvironmental change, as well as the product of episodes of paleoceanographic and paleoenvironmental change themselves.

  18. Methods of Thermal Calculations for a Condensing Waste-Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Rączka Paweł

    2014-12-01

    Full Text Available The paper presents the algorithms for a flue gas/water waste-heat exchanger with and without condensation of water vapour contained in flue gas with experimental validation of theoretical results. The algorithms were used for calculations of the area of a heat exchanger using waste heat from a pulverised brown coal fired steam boiler operating in a power unit with a capacity of 900 MWe. In calculation of the condensing part, the calculation results obtained with two algorithms were compared (Colburn-Hobler and VDI algorithms. The VDI algorithm allowed to take into account the condensation of water vapour for flue gas temperatures above the temperature of the water dew point. Thanks to this, it was possible to calculate more accurately the required heat transfer area, which resulted in its reduction by 19 %. In addition, the influence of the mass transfer on the heat transfer area was taken into account, which contributed to a further reduction in the calculated size of the heat exchanger - in total by 28% as compared with the Colburn-Hobler algorithm. The presented VDI algorithm was used to design a 312 kW pilot-scale condensing heat exchanger installed in PGE Belchatow power plant. Obtained experimental results are in a good agreement with calculated values.

  19. Plant balance model for RELAP/SCDAPSIM

    International Nuclear Information System (INIS)

    Mendoza M, R.; Filio L, C.; Araiza M, E.; Ortiz V, J.

    2017-09-01

    In this work we developed an integral model for a nuclear power plant and have a more general picture of what happens in both the Nuclear Steam Supply System (NSSS) and the Balance of Plant (Bop) system during abnormal events that are presented in operation. RELAP/SCDAPSIM (RSS) is a computation code of the type of best estimate that can simulate the transient and accident behavior of a nuclear installation. The development of a Bop model for RSS can result in the simulation of transients such as turbine trip due to loss of vacuum in the main steam condenser. This work shows the development of models of the Bop main components for the RSS code, such as the set of high and low pressure turbines, as well as their steam extractions to the feed water heaters, the main steam condenser, a feed water heater and the condensate and water feed pumps. This new model of the Plant Balance system was then coupled to the NSSS model that is already in RSS. First, results of the steady state with this new integral model are show, to later show results of the transients simulation: 1) turbine trip due to loss of vacuum in the main steam condenser; 2) loss of condensate pumps; and 3) failure of the feed water heater. (Author)

  20. Chemical operational experiences in the Belgian nuclear power plants of Doel and Tihange

    International Nuclear Information System (INIS)

    Roofthooft, R.

    1977-01-01

    The nuclear program in Belgium started in 1962 with the commissioning of a small reactor BR3 and continued with Chooz, Doel and Tihange. This report gives a survey of the chemical experiences in Doal and Tihange. All these units are of the PWR type constructed by Westinghouse. The chemical specifications for the secondary circuit are very severe and difficult to maintain without condensate polishing system for units such as Doel 1 and 2, cooled with estuary brackish water. The condensate polishing system of Doel is described and the main results are given. The big problem of this station has been the behaviour of the condenser tubes. After 1 and 2 years of operation severe corrosion developed and a retubing became necessary. In the steam generators of Doel and Tihange deposits of a few cm are found. The denting problem has also started. Tihange has worked nearly one year with a leak in one of the steam generators. The blow down was treated on ion exchangers. The fuel elements have had a good behaviour especially in Doel 1. During shut down periods for refuelling H 2 O 2 is injected in the primary circuit. This gives a quick release of corrosion products. The activity of 58 Co increases to about 0,4 Ci/m 3 . A precoat filter with pulverised resins gives a good decontamination factor in this case. The liquid waste treatment of Doel has been modified in order to cope with the quantities of effluents. In Tihange it has been necessary to decontaminate a primary pump. This has been done with Turco products. Very good results have been obtained. (orig.) [de

  1. Wear characteristics of polished and glazed lithium disilicate ceramics opposed to three ceramic materials.

    Science.gov (United States)

    Saiki, Osamu; Koizumi, Hiroyasu; Akazawa, Nobutaka; Kodaira, Akihisa; Okamura, Kentaro; Matsumura, Hideo

    2016-01-01

    This study compared the wear characteristics of a heat-pressed lithium disilicate ceramic material opposed to feldspathic porcelain, a lithium disilicate glass ceramic, and zirconia materials. Ceramic plate specimens were prepared from feldspathic porcelain (EX-3 nA1B), lithium disilicate glass ceramics (e.max CAD MO1/C14), and zirconia (Katana KT 10) and then ground or polished. Rounded rod specimens were fabricated from heat-pressed lithium disilicate glass ceramic (e.max press LT A3) and then glazed or polished. A sliding wear testing apparatus was used for wear testing. Wear of glazed rods was greater than that of polished rods when they were abraded with ground zirconia, ground porcelain, polished porcelain, or polished lithium disilicate ceramics. For both glazed and polished rods, wear was greater when the rods were abraded with ground plates. The findings indicate that application of a polished surface rather than a glazed surface is recommended for single restorations made of heat-pressed lithium disilicate material. In addition, care must be taken when polishing opposing materials, especially those used in occlusal contact areas. (J Oral Sci 58, 117-123, 2016).

  2. High-efficiency condenser of steam from a steam-gas mixture

    Science.gov (United States)

    Milman, O. O.; Krylov, V. S.; Ptakhin, A. V.; Kondratev, A. V.; Yankov, G. G.

    2017-12-01

    The design of a module for a high-efficiency condenser of steam with a high content (up to 15%) of noncondensable gases (NCGs) with a nearly constant steam-gas mixture (SGM) velocity during the condensation of steam has been developed. This module provides the possibility to estimate the operational efficiency of six condenser zones during the motion of steam from the inlet to the SGM suction point. Some results of the experimental tests of the pilot high-efficiency condenser module are presented. The dependence of the average heat transfer coefficient k¯ on the volumetric NCG concentration v¯ has been derived. It is shown that the high-efficiency condenser module can provide a moderate decrease in k¯ from 4400-4600 to 2600-2800 W/(m2 K) at v¯ ≈ 0.5-9.0%. The heat transfer coefficient distribution over different module zones at a heat duty close to its nominal value has been obtained. From this distribution, it can be seen that the average heat transfer coefficient decreases to 2600 W/(m2 K) at an NCG concentration v¯ = 7.5%, but the first condenser sections ( 1- 3) retain high values of k¯ at a level of no lower than 3200 W/(m2 K), and the last sections operate less well, having k¯ at a level of 1700 W/(m2 K). The dependence of the average heat transfer coefficient on the water velocity in condenser tubes has been obtained at a nearly nominal duty such that the extrapolation of this dependence to the water velocity of 2 m/s may be expected to give k¯ = 5000 W/(m2 K) for relatively pure steam, but an increase in k¯ at v¯ = 8% will be smaller. The effect of the gas removal device characteristic on the operation of the high-efficiency condenser module is described. The design developed for the steam condenser of a gas-turbine plant with a power of 25 MW, a steam flow rate of 40.2 t/h, and a CO2 concentration of up to 12% with consideration for the results of performed studies is presented.

  3. Low speed turbines for nuclear power plants

    International Nuclear Information System (INIS)

    Ugol'nikov, V.V.; Kosyak, Yu.F.; Virchenko, M.A.

    1975-01-01

    Work of the Kharkov turbine plant on planning and manufacture for nuclear power plants of low-speed (1500 rpm) turbines with a power of 500-1000 MW is described. The selection of a construction diagram for the turbine assembly, determined basically by the presence or absence of parts of average pressure, is considered. Special construction features of the condenser and turbine are described. Turbine K-500, with a rate of 1500 rpm, was calculated for operation in a two-loop nuclear power plant with saturated steam with intermediate separation and two-stage steam regeneration. On the base of this turbine, three models of 1000-MW turbines were developed. The first model has a cylinder of average pressure (TsSD) and a lateral condenser. The second has no TsSD but a low location of the condensers. The third has no TsSD and the condensers are located laterally. Calculations of the heat efficiency of the three types of turbines showed that several advantages are offered by the model with a TsSD. Better aerodynamic properties of the exhaust nozzles and condensers with lateral location allows decreasing the specific heat consumption to 0.5-1% or, at the same power, a 10-20% decrease in cooling water consumption

  4. Microscopic machining mechanism of polishing based on vibrations of liquid

    International Nuclear Information System (INIS)

    Huang, Z G; Guo, Z N; Chen, X; Yu, Z Q; Yu, T M; Lee, W B

    2007-01-01

    A molecular dynamics method has been applied to study the mechanism of polishing based on vibrations of liquid. Movements of polishing particles and formations of impact dents are simulated and discussed. The abrasive effect between particle and machined substrate is evaluated empirically. Polishing qualities, including roughness and fractal character under multiple impacts, are obtained by numerical methods. Results show that the particle will vibrate and roll viscously on the substrate. Press, tear and self-organization effects will be responsible for the formation of impact dents. Simulation results are compared with experimental data to verify the conclusions

  5. Models of nanoparticles movement, collision, and friction in chemical mechanical polishing (CMP)

    Energy Technology Data Exchange (ETDEWEB)

    Ilie, Filip, E-mail: filip@meca.omtr.pub.ro [Polytechnic University of Bucharest, Department of Machine Elements and Tribology (Romania)

    2012-03-15

    Nanoparticles have been widely used in polishing slurry such as chemical mechanical polishing (CMP) process. The movement of nanoparticles in polishing slurry and the interaction between nanoparticles and solid surface are very important to obtain an atomic smooth surface in CMP process. Polishing slurry contains abrasive nanoparticles (with the size range of about 10-100 nm) and chemical reagents. Abrasive nanoparticles and hydrodynamic pressure are considered to cause the polishing effect. Nanoparticles behavior in the slurry with power-law viscosity shows great effect on the wafer surface in polishing process. CMP is now a standard process of integrated circuit manufacturing at nanoscale. Various models can dynamically predict the evolution of surface topography for any time point during CMP. To research, using a combination of individual nanoscale friction measurements for CMP of SiO{sub 2}, in an analytical model, to sum these effects, and the results scale CMP experiments, can guide the research and validate the model. CMP endpoint measurements, such as those from motor current traces, enable verification of model predictions, relating to friction and wear in CMP and surface topography evolution for different types of CMP processes and patterned chips. In this article, we explore models of the microscopic frictional force based on the surface topography and present both experimental and theoretical studies on the movement of nanoparticles in polishing slurry and collision between nanoparticles, as well as between the particles and solid surfaces in time of process CMP. Experimental results have proved that the nanoparticle size and slurry properties have great effects on the polishing results. The effects of the nanoparticle size and the slurry film thickness are also discussed.

  6. Characteristics of flow in turbine-condenser connections

    International Nuclear Information System (INIS)

    Yasugahira, Norio; Sato, Takeshi; Mukai, Yasuteru; Otake, Katsumoto; Miyai, Masahiko

    1981-01-01

    It is important to save energy in thermal and nuclear power plants, and Hitachi Ltd. has exerted efforts on this subject. The performance of condensers depends largely on the condition of steam flow into the tube nests, and is affected by the state of steam flow in the connecting parts between LP turbines and the condensers. It is desirable to give turbines low exhaust pressure by minimizing the resistance of the obstacles in the diffuser paths and increasing the restoration of static pressure. But in the connecting parts, feed water heaters, bleeding pipes and stiffeners are placed, and if these re arranged inadequately, the performance of condensers and the efficiency of turbines are lowered by pressure loss. In this study, the flow in the connecting parts was reproduced with models, and the detailed state of internal flow was grasped. Also the influence of the form of the connecting parts, feed water heaters and bleeding pipes on pressure loss was examined, and the measures to reduce the pressure loss were sought. The cases of the connecting parts containing one feed water heater and four feed water heaters were examined. The experimental setup, the structure of the tested models, and the test results are reported. The velocity distribution and flow pattern of the internal flow were obtained, and the arrangement of feed water heaters which reduces pressure loss was clarified. (Kako, I.)

  7. Effects of air-polishing powders on color stability of composite resins.

    Science.gov (United States)

    Güler, Ahmet Umut; Duran, Ibrahim; Yücel, Ali Çağin; Ozkan, Pelin

    2011-10-01

    The purpose of this study was to investigate the effect of different air-polishing powders on the color stability of different types of composite resin restorative materials. Thirty cylindrical specimens (15×2 mm) were prepared for each of 7 composite resin restorative materials. All specimens were polished with a series of aluminum oxide polishing discs (Sof-Lex). The prepared specimens of each composite resin were randomly divided into 3 groups of 10 specimens each, for control (Group-C) and two air-powder applications (Group-CP: Cavitron Prophy-Jet; Group-PS: Sirona ProSmile prophylaxis powder). A standard air-polishing unit (ProSmile Handly) was used. All specimens were air-powdered for 10 s at 4-bar pressure. The distance of the spray nosel from the specimens was approximately 10 mm and angulation of the nosel was 90°. Specimens were stored in 100 mL of coffee (Nescafe Classic) for 24 h at 37°C. Color measurement of all specimens was recorded before and after exposure to staining agent with a colorimeter (Minolta CR-300). Color differences (∆E*) between the 2 color measurements (baseline and after 24 h storage) were calculated. The data were analyzed with a 2-way ANOVA test, and mean values were compared by the Tukey HSD test (p.05) and these groups demonstrated the highest ∆E* values. For Filtek Silorane and IntenS, the highest ∆E* values were observed in Group-PS. The lowest ∆E* values for all composite resin groups were observed in Group-C. When comparing the 7 composite resin restorative materials, Aelite Aesthetic Enemal demonstrated significantly less ∆E* values than the other composite resins tested. The highest ∆E* values were observed in Quixfil. Except for Quixfil, all control groups of composite resins that were polished Sof-Lex exhibited clinically acceptable ∆E values (<3.7). Air-polishing applications increased the color change for all composite resin restorative materials tested. Composite restorations may require re-polishing

  8. Effects of air-polishing powders on color stability of composite resins

    Directory of Open Access Journals (Sweden)

    Ahmet Umut Güler

    2011-10-01

    Full Text Available OBJECTIVES: The purpose of this study was to investigate the effect of different air-polishing powders on the color stability of different types of composite resin restorative materials. MATERIAL AND METHODS: Thirty cylindrical specimens (15×2 mm were prepared for each of 7 composite resin restorative materials. All specimens were polished with a series of aluminum oxide polishing discs (Sof-Lex. The prepared specimens of each composite resin were randomly divided into 3 groups of 10 specimens each, for control (Group-C and two air-powder applications (Group-CP: Cavitron Prophy-Jet; Group-PS: Sirona ProSmile prophylaxis powder. A standard air-polishing unit (ProSmile Handly was used. All specimens were air-powdered for 10 s at 4-bar pressure. The distance of the spray nosel from the specimens was approximately 10 mm and angulation of the nosel was 90°. Specimens were stored in 100 mL of coffee (Nescafe Classic for 24 h at 37°C. Color measurement of all specimens was recorded before and after exposure to staining agent with a colorimeter (Minolta CR-300. Color differences (∆E* between the 2 color measurements (baseline and after 24 h storage were calculated. The data were analyzed with a 2-way ANOVA test, and mean values were compared by the Tukey HSD test (p.05 and these groups demonstrated the highest ∆E* values. For Filtek Silorane and IntenS, the highest ∆E* values were observed in Group-PS. The lowest ∆E* values for all composite resin groups were observed in Group-C. When comparing the 7 composite resin restorative materials, Aelite Aesthetic Enemal demonstrated significantly less ∆E* values than the other composite resins tested. The highest ∆E* values were observed in Quixfil. CONCLUSION: Except for Quixfil, all control groups of composite resins that were polished Sof-Lex exhibited clinically acceptable ∆E values (<3.7. Air-polishing applications increased the color change for all composite resin restorative materials

  9. Material removal mechanisms in electrochemical-mechanical polishing of tantalum

    International Nuclear Information System (INIS)

    Gao, F.; Liang, H.

    2009-01-01

    Material removal mechanisms in tantalum chemical-mechanical polishing (CMP) and electrochemical-mechanical polishing (ECMP) were investigated using the single frequency electrochemical impedance spectroscopy (EIS). Through measuring the impedance of the tantalum surface, the single frequency EIS scan made it possible to observe the CMP and ECMP processes in situ. The impedance results presented competing mechanisms of removal and formation of a surface oxide layer of tantalum. Analysis indicated that the thickness of the oxide layer formed during polishing was related to the mechanical power correlated to the friction force and the rotating speed. Furthermore, the rate of growth and removal of the oxide film was a function of the mechanical power. This understanding is beneficial for optimization of CMP and ECMP processes.

  10. [Polish medical ethics in the period 1945-1980].

    Science.gov (United States)

    Wichrowski, Marek

    2003-01-01

    The purpose of this article is o present that main currents of Polish medical ethics in the years 1945-1980, which the author treats as the 'prehistory' of Poland's contemporary bioethics. The author begins by ascertaining the post-war disappearance of two Polish traditions--that of the Warsaw school of philosopher-physicians (known in the West as the Polish School of Philosophy of Medicine) and the Lwów-Warsaw School of Philosophy. The political system that come into being after 1945 was not conducive to the development of medical ethics, but several clear orientations may be discerned in the utterances of physicians, lawyers, moral technologlans and academic philosophers. The analysis begins with Catholic ethics in its archaic 1950s-vintage form. The author then presents the thinking of ethicians Independent of both the Church and Marxism (the milieu of the journal 'Etyka') as well as the deontological writings of physicians.

  11. Possibility of removing condensate and scattered oil from gas-condensate field during bed flooding

    Energy Technology Data Exchange (ETDEWEB)

    Belkina, N.A.; Yagubov, M.S.

    1984-01-01

    The problem is set of evaluating the possible removal from the bed of scattered oil and condensate during flooding of the bed. For this purpose, an experimental study was made of the displacement by water from the porous medium of the oil and condensate saturating it. The obtained experimental results permit evaluation of the possible removal from the gas-condensate bed of scattered oil and condensate during flooding of the bed.

  12. Humidification Dehumidification Spray Column Direct Contact Condenser Part I: Countercurrent Flow

    International Nuclear Information System (INIS)

    Shouman, L.; Karameldin, A.; Fadel, D.

    2015-01-01

    Humidification-dehumidification (HDH) is a low grade energy desalination technology. The waste heat from power plant (such NPP) can be used as heat source to preheat water (in evaporator) and air (in condenser) . Hot humid air and cooled spray water in counter current flow with direct contact is theoretically analyzing in the present work. Direct contact spray condenser is studied to provide the effect of various parameters on its performance. A computer programme describing the theoretical model is designed to solve a one-dimensional differential equations by using Rung–Kutta method. The programme predicts the droplet radius, velocity and temperature, besides, the humidity and temperature of air. The results show that, the length of column has great effect on the performance of spray condenser. At column height of 0.762, 2, 5, 10, and 20 m the humidity of the output air decreases by 50%, 72%, 89%, 97%, and 99% respectively. The condensate increases about 35% when the length increase from 5 to 10 m at ΔT = 25°C while increase only 18% at ΔT = 30°C. Also, it is found that, at ΔT = 25°C the condensate decrease from H = 10 to 5 m about 31% and increases from 10 to 20 m about 32%. While these results for ΔT = 25°C are 32% from H = 10 to 5 m and 36% from 10 to 20 m.The increase of both water and air mass fluxes increases the condensate mass flow rate. (author)

  13. Research progress of control of condensate depression for condenser

    Science.gov (United States)

    Liu, Ying; Liang, Run; Li, Fengyu

    2017-08-01

    It is introduced that significance and structure of the condensate depression control system. In accordance with controller devised procedure, we analyze and elaborate how to construct the lumped parameter and dynamic mathematical model which possesses distinct physics significance. Neural network model being called black-box model is also introduced. We analyze and contrast the control technique of condensate depression as conventional PI control, fuzzy PI control and fuzzy control. It is indicated that if the controller of condensate depression were devised inappropriate, while the steam discharged of turbine varying by a large margin, would result in the rotation rate of cooling water circulating pump accelerating at a great lick even to trigger the galloping danger which is less impressive for the units operating safely.

  14. Universal Themes of Bose-Einstein Condensation

    Science.gov (United States)

    Proukakis, Nick P.; Snoke, David W.; Littlewood, Peter B.

    2017-04-01

    Foreword; List of contributors; Preface; Part I. Introduction: 1. Universality and Bose-Einstein condensation: perspectives on recent work D. W. Snoke, N. P. Proukakis, T. Giamarchi and P. B. Littlewood; 2. A history of Bose-Einstein condensation of atomic hydrogen T. Greytak and D. Kleppner; 3. Twenty years of atomic quantum gases: 1995-2015 W. Ketterle; 4. Introduction to polariton condensation P. B. Littlewood and A. Edelman; Part II. General Topics: Editorial notes; 5. The question of spontaneous symmetry breaking in condensates D. W. Snoke and A. J. Daley; 6. Effects of interactions on Bose-Einstein condensation R. P. Smith; 7. Formation of Bose-Einstein condensates M. J. Davis, T. M. Wright, T. Gasenzer, S. A. Gardiner and N. P. Proukakis; 8. Quenches, relaxation and pre-thermalization in an isolated quantum system T. Langen and J. Schmiedmayer; 9. Ultracold gases with intrinsic scale invariance C. Chin; 10. Berezinskii-Kosterlitz-Thouless phase of a driven-dissipative condensate N. Y. Kim, W. H. Nitsche and Y. Yamamoto; 11. Superfluidity and phase correlations of driven dissipative condensates J. Keeling, L. M. Sieberer, E. Altman, L. Chen, S. Diehl and J. Toner; 12. BEC to BCS crossover from superconductors to polaritons A. Edelman and P. B. Littlewood; Part III. Condensates in Atomic Physics: Editorial notes; 13. Probing and controlling strongly correlated quantum many-body systems using ultracold quantum gases I. Bloch; 14. Preparing and probing chern bands with cold atoms N. Goldman, N. R. Cooper and J. Dalibard; 15. Bose-Einstein condensates in artificial gauge fields L. J. LeBlanc and I. B. Spielman; 16. Second sound in ultracold atomic gases L. Pitaevskii and S. Stringari; 17. Quantum turbulence in atomic Bose-Einstein condensates N. G. Parker, A. J. Allen, C. F. Barenghi and N. P. Proukakis; 18. Spinor-dipolar aspects of Bose-Einstein condensation M. Ueda; Part IV. Condensates in Condensed Matter Physics: Editorial notes; 19. Bose

  15. The research activities on in-tube condensation in the presence of noncondensables for passive cooling applications

    Energy Technology Data Exchange (ETDEWEB)

    Tanrikut, A [Turkish Atomic Energy Authority, Ankara (Turkey)

    1996-12-01

    The introduction of nuclear power becomes an attractive solution to the problem of increasing demand for electricity power capacity in Turkey. Thus, Turkey is willing to follow the technological development trends in advanced reactor systems and to participate in joint research studies. The primary objectives of the passive design features are to simplify the design, which assures the minimized demand on operator, and to improve plant safety. To accomplish these features the operating principles of passive safety systems should be well understood by an experimental validation program. Such a validation program is also important for the assessment of advanced computer codes which are currently used for design and licensing procedures. The condensation mode of heat transfer plays an important role for the passive heat removal applications in the current nuclear power plants (e.g. decay heat removal via steam generators in case of loss of heat removal system) and advanced water-cooled reactor systems. But is well established that the presence of noncondensable gases can greatly inhibit the condensation process due to the build-up of noncondensable gas concentration at the liquid/gas interface. The isolation condenser of passive containment cooling system of the simplified boiling water reactors is a typical application area of in-tube condensation in the presence of noncondensable. This paper describes the research activities at the Turkish Atomic Energy Authority concerning condensation in the presence of air, as a noncondensable gas. (author). 9 refs, 6 figs.

  16. The research activities on in-tube condensation in the presence of noncondensables for passive cooling applications

    International Nuclear Information System (INIS)

    Tanrikut, A.

    1996-01-01

    The introduction of nuclear power becomes an attractive solution to the problem of increasing demand for electricity power capacity in Turkey. Thus, Turkey is willing to follow the technological development trends in advanced reactor systems and to participate in joint research studies. The primary objectives of the passive design features are to simplify the design, which assures the minimized demand on operator, and to improve plant safety. To accomplish these features the operating principles of passive safety systems should be well understood by an experimental validation program. Such a validation program is also important for the assessment of advanced computer codes which are currently used for design and licensing procedures. The condensation mode of heat transfer plays an important role for the passive heat removal applications in the current nuclear power plants (e.g. decay heat removal via steam generators in case of loss of heat removal system) and advanced water-cooled reactor systems. But is well established that the presence of noncondensable gases can greatly inhibit the condensation process due to the build-up of noncondensable gas concentration at the liquid/gas interface. The isolation condenser of passive containment cooling system of the simplified boiling water reactors is a typical application area of in-tube condensation in the presence of noncondensable. This paper describes the research activities at the Turkish Atomic Energy Authority concerning condensation in the presence of air, as a noncondensable gas. (author). 9 refs, 6 figs

  17. Polish adaptation of scoliosis research society-22 questionnaire.

    Science.gov (United States)

    Glowacki, Maciej; Misterska, Ewa; Laurentowska, Maria; Mankowski, Przemyslaw

    2009-05-01

    Polish adaptation of the original version of Scoliosis Research Society (SRS) instrument. The transcultural adaptation of SRS-22 and evaluation of its internal consistency. High psychometric value of the SRS-22 Questionnaire has made it an effective evaluation instrument in clinically assessing the functional status of patients with adolescent idiopathic scoliosis. First, 2 translators translated the original version into Polish. Afterwards, the translators identified differences between the translations and produced a consensus version. In the third stage, 2 native English speakers produced back translations. Finally, a team of 2 orthopedic surgeons, translators, a statistician and a psychologist reviewed all the translations to produce a prefinal version. The questionnaire was administered to 60 girls at the age of 16.6, SD 2.0 with adolescent idiopathic scoliosis treated with the Cotrel-Dubousset method in Pediatric Orthopaedics and Traumatology Clinic in Poznań. The internal consistency in the Polish version equaled 0.89 for the overall result and 0.81 for function, 0.81 for pain, 0.80 for mental health, 0.77 for self-image, and 0.69 for treatment satisfaction domains, respectively. The Polish version of SRS-22 is characterized by high internal consistency for all domains and for the overall score, which makes it an evaluation tool after surgical treatment compatible with the original SRS-22.

  18. Assessment of TRACE Condensation Model Against Reflux Condensation Tests with Noncondensable Gases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Won; Cheong, Ae Ju; Shin, Andong; Suh, Nam Duk [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-05-15

    The TRACE is the latest in a series of advanced, best-estimated reactor systems code developed by U.S. Nuclear Regulatory Commission for analyzing transient and steady-state neutronic-thermal-hydraulic behavior in light water reactors. This special model is expected to replace the default model in a future code release after sufficient testing has been completed. This study assesses the special condensation model of TRACE 5.0-patch4 against the counter-current flow configuration. For this purpose, the predicted results of special model are compared to the experimental and to those of default model. The KAST reflux condensation test with NC gases are used in this assessment. We assessed the special model for film condensation of TRACE 5.0-patch4 against the data of the reflux condensation test in the presence of NC gases. The special condensation model of TRACE provides a reasonable estimate of HTC with good agreement at the low inlet steam flow rate.

  19. Assessment of TRACE Condensation Model Against Reflux Condensation Tests with Noncondensable Gases

    International Nuclear Information System (INIS)

    Lee, Kyung Won; Cheong, Ae Ju; Shin, Andong; Suh, Nam Duk

    2015-01-01

    The TRACE is the latest in a series of advanced, best-estimated reactor systems code developed by U.S. Nuclear Regulatory Commission for analyzing transient and steady-state neutronic-thermal-hydraulic behavior in light water reactors. This special model is expected to replace the default model in a future code release after sufficient testing has been completed. This study assesses the special condensation model of TRACE 5.0-patch4 against the counter-current flow configuration. For this purpose, the predicted results of special model are compared to the experimental and to those of default model. The KAST reflux condensation test with NC gases are used in this assessment. We assessed the special model for film condensation of TRACE 5.0-patch4 against the data of the reflux condensation test in the presence of NC gases. The special condensation model of TRACE provides a reasonable estimate of HTC with good agreement at the low inlet steam flow rate

  20. SAFETY PLATFORM OF POLISH TRANSPORT

    Directory of Open Access Journals (Sweden)

    Katarzyna CHRUZIK

    2016-03-01

    Full Text Available Analyzing the level of Polish transport safety culture can be seen that it is now dependent on the culture of safety management within the organization and the requirements and recommendations of law in this field for different modes of transport (air, rail, road, water. Of the four basic types of transport requirements are widely developed in the aviation, rail, and water – the sea. In order to harmonize the requirements for transport safety so it appears advisable to develop a platform for exchange of safety information for different modes of transport, and the development of good practices multimodal offering the possibility of improving Polish transport safety. Described in the publication of the proposal in addition to the alignment platform experience and knowledge in the field of transport safety in all its kinds, it can also be a tool for perfecting new operators of public transport.

  1. Effect finishing and polishing procedures on the surface roughness of IPS Empress 2 ceramic.

    Science.gov (United States)

    Boaventura, Juliana Maria Capelozza; Nishida, Rodrigo; Elossais, André Afif; Lima, Darlon Martins; Reis, José Mauricio Santos Nunes; Campos, Edson Alves; de Andrade, Marcelo Ferrarezi

    2013-01-01

    To evaluate the surface roughness of IPS Empress 2 ceramic when treated with different finishing/polishing protocols. Sixteen specimens of IPS Empress 2 ceramic were made from wax patterns obtained using a stainless steel split mold. The specimens were glazed (Stage 0-S0, control) and divided into two groups. The specimens in Group 1 (G1) were finished/polished with a KG Sorensen diamond point (S1), followed by KG Sorensen siliconized points (S2) and final polishing with diamond polish paste (S3). In Group 2 (G2), the specimens were finished/polished using a Shofu diamond point (S1), as well as Shofu siliconized points (S2) and final polishing was performed using Porcelize paste (S3). After glazing (S0) and following each polishing procedure (S1, S2 or S3), the surface roughness was measured using TALYSURF Series 2. The average surface roughness results were analyzed using ANOVA followed by Tukey post-hoc tests (α = 0.01) RESULTS: All of the polishing procedures yielded higher surface roughness values when compared to the control group (S0). S3 yielded lower surface roughness values when compared to S1 and S2. The proposed treatments negatively affected the surface roughness of the glazed IPS Empress 2 ceramic.

  2. Nuclear power plants

    International Nuclear Information System (INIS)

    Ushijima, Susumu.

    1984-01-01

    Purpose: To enable to prevent the degradation in the quality of condensated water in a case where sea water leakage should occur in a steam condenser of a BWR type nuclear power plant. Constitution: Increase in the ion concentration in condensated water is detected by an ion concentration detector and the leaking factor of sea water is calculated in a leaking factor calculator. If the sea water leaking factor exceeds a predetermined value, a leak generation signal is sent from a judging device to a reactor power control device to reduce the reactor power. At ehe same tiem, the leak generation signal is also sent to a steam condenser selection and isolation device to interrupt the sea water pump of a specified steam condenser based on the signal from the ion concentration detector, as well as close the inlet and outlet valves while open vent and drain valves to thereby forcively discharge the sea water in the cooling water pipes. This can keep the condensate desalting device from ion breaking and prevent the degradation in the quality of the reactor water. (Horiuchi, T.)

  3. The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics

    Science.gov (United States)

    Demirci, Tevfik; Demirci, Gamze; Sagsoz, Nurdan Polat; Yildiz, Mehmet

    2016-01-01

    PURPOSE The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples (8 × 8 × 1 mm) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (α=.05). RESULTS The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (PCeramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics. PMID:28018558

  4. Report of a consultants meeting on the review of Bubbler condenser structural integrity calculations

    International Nuclear Information System (INIS)

    Andrieu, R.; Balaz, P.; Kucera, V.; Kudriashov, A.N.; Orden, A.; Strupczewski, A.; Timoshenko, V.

    1995-01-01

    The participants of the meeting on peer review were the experts who have already made their own strength calculations for WWER 440/213 bubbler condenser structures or who had experience in strength calculations of similar structures. The list of participants is given in Appendix 1. The results have confirmed that the weak points indicated in previous calculations should be strengthened. Some suggestions were given concerning possible ways of strengthening the bubbler condenser structure. However, as the required work is extensive, and the conditions of its realization are difficult, it was recommended to conduct site specific reviews of the actual situation in bubbler condenser structure in each plant before any final recommendations can be formulated. The results of this peer review are presented. 10 refs, figs, tab

  5. High voltage performance of a dc photoemission electron gun with centrifugal barrel-polished electrodes

    Science.gov (United States)

    Hernandez-Garcia, C.; Bullard, D.; Hannon, F.; Wang, Y.; Poelker, M.

    2017-09-01

    The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain work, we describe a centrifugal barrel-polishing technique commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (˜11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.

  6. Polishing and toothbrushing alters the surface roughness and gloss of composite resins.

    Science.gov (United States)

    Kamonkhantikul, Krid; Arksornnukit, Mansuang; Takahashi, Hidekazu; Kanehira, Masafumi; Finger, Werner J

    2014-01-01

    This study aimed to investigate the surface roughness and gloss of composite resins after using two polishing systems and toothbrushing. Six composite resins (Durafill VS, Filtek Z250, Filtek Z350 XT, Kalore, Venus Diamond, and Venus Pearl) were evaluated after polishing with two polishing systems (Sof-Lex, Venus Supra) and after toothbrushing up to 40,000 cycles. Surface roughness (Ra) and gloss were determined for each composite resin group (n=6) after silicon carbide paper grinding, polishing, and toothbrushing. Two-way ANOVA indicated significant differences in both Ra and gloss between measuring stages for the composite resins tested, except Venus Pearl, which showed significant differences only in gloss. After polishing, the Filtek Z350 XT, Kalore, and Venus Diamond showed significant increases in Ra, while all composite resin groups except the Filtek Z350 XT and Durafill VS with Sof-Lex showed increases in gloss. After toothbrushing, all composite resin demonstrated increases in Ra and decreases in gloss.

  7. Boiling, condensation, and gas-liquid flow

    International Nuclear Information System (INIS)

    Whalley, P.B.

    1987-01-01

    Heat transfer phenomena involving boiling and condensation are an important aspect of engineering in the power and process industries. This book, aimed at advanced first-degree and graduate students in mechanical and chemical engineering, deals with these phenomena in detail. The first part of the book describes gas-liquid two-phase flow, as a necessary preliminary to the later discussion of heat transfer and change of phase. A detailed section on calculation methods shows how theory can be put to practical use, and there are also descriptions of some of the equipment and plant used in the process and power industries

  8. Modelling of film condensation on the reactor containment walls

    International Nuclear Information System (INIS)

    Leduc, Christian

    1995-01-01

    A containment code used in nuclear plant safety analysis must be able to predict evolutions of steam, air and hydrogen concentrations and pressure in the containment of a pressurized water reactor in an accidental situation. Steam condensation on cold walls is an essential factor for these evolutions as it allows the release of an important heat flow, and locally reduces steam concentration. In this research thesis, the author proposes a film condensation model in presence of un-condensable gases. The film flow is supposed to be laminar. Three different approaches are used to model transfers in boundary layers: global correlations in which a hybrid Grashof number is used which expresses the mass and thermal nature of convection, a boundary layer calculation using wall rules for a forced convection regime, and a boundary layer calculation using a k-epsilon model with a low Reynolds number for a natural convection regime. Each approach requires very different mesh fineness at the vicinity of the wall. Models are implemented in the 3-D TRIO-VF thermo-hydraulic code. The obtained theoretical heat transfer coefficients are compared with experimental results [fr

  9. Polish students at the Académie Julian until 1919

    Directory of Open Access Journals (Sweden)

    Zgórniak, Marek

    2012-08-01

    Full Text Available The subject of the article is the presence of Polish students in the most important private artistic school in Paris in the second half of the 19thcentury. The extant records regarding the atelier for male students made it possible to compile a list of about 165 Polish painters and sculptors studying there in the period from 1880 to 1919. The text presents the criteria used when preparing the list and the diagrams show the fluctuations in registration and the number of Polish artists in particular ateliers in successive years. The observations contained in the article have a summary nature and are illustrated only with selected examples.

  10. Operative behaviour of a condenser tube under ETA chemistry

    International Nuclear Information System (INIS)

    Chocron, Mauricio; Burkart, Arturo; Rodriguez, Ivanna; Raul, Manera; Diego, Quinteros

    2012-09-01

    Among the various recommendations for the surveillance of the integrity of the materials of the Secondary Cycle (Balance of Plant) it is the periodic removal of a steam generator tube and a condenser tube and their analysis. It considers assessment of the water chemistry, corrosion and the reciprocal effect on or from other components of the cycle. Embalse N.P.P. is a CANDU 6 type, Pressurized Heavy Water Reactor, located in Cordoba Province, Argentina. Previous papers have shown results on tubes removed from the steam generators (Bordoni et al., NPC'08, September 15-18, 2008, Berlin, Germany; 6 th Canadian Nuclear Society - Steam Generators Conference, November 8-11, 2009, Toronto, Canada). Considering that the Embalse BOP has mixed metallurgy, i.e., steam generator tubes made of A800, piping made of ferrous alloys and condenser tubes made of Admiralty Brass and also taking into account that the chemistry has been modified from Morpholine control to ETA control (Fernandez et. al, NPC'2010, October 3-7, Quebec City, Canada), it has been decided to remove and analyze a condenser tube that has been placed in operation coincidently with the establishment of the ETA chemical control. The extraction is dated along with the November 2011 Plant Programmed Outage. Objectives are assessing the operative behavior of the tube performing visual and optical microscope inspection, SEM analysis of the oxides and deposits in exposed surfaces and occluded locations like tube sheet and other tests as well. Results are compared to the same analysis performed on a new tube in storage and integrated with the chemical operative figures of the cycle during the period: chemical data and corrosion products transport. (authors)

  11. Neologisms in bilingual digital dictionaries (on the example of Bulgarian-Polish dictionary

    Directory of Open Access Journals (Sweden)

    Ludmila Dimitrova

    2015-11-01

    Full Text Available Neologisms in bilingual digital dictionaries (on the example of Bulgarian-Polish dictionary The paper discusses the presentation of neologisms in the recent version of the Bulgarian-Polish digital dictionary. We also continue the discussion of important problems related to the classifiers of the verbs as headwords of the digital dictionary entries. We analyze some examples from ongoing experimental version of the Bulgarian-Polish digital dictionary.

  12. Laboratory Scoping Tests Of Decontamination Of Hanford Waste Treatment Plant Low Activity Waste Off-Gas Condensate Simulant

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, Kathryn M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Nash, Charles A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Crawford, Charles L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, Daniel J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Wilmarth, William R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2014-01-21

    The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of glass waste. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to acceptable concentrations in the LAW glass, and diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task seeks to examine the potential treatment of this stream to remove radionuclides and subsequently disposition the decontaminated stream elsewhere, such as the Effluent Treatment Facility (ETF), for example. The treatment process envisioned is very similar to that used for the Actinide Removal Process (ARP) that has been operating for years at the Savannah River Site (SRS), and focuses on using mature radionuclide removal technologies that are also

  13. Implementation of non-condensable gases condensation suppression model into the WCOBRA/TRAC-TF2 LOCA safety evaluation code

    Energy Technology Data Exchange (ETDEWEB)

    Liao, J.; Cao, L.; Ohkawa, K.; Frepoli, C. [LOCA Integrated Services I, Westinghouse Electric Company, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2012-07-01

    The non-condensable gases condensation suppression model is important for a realistic LOCA safety analysis code. A condensation suppression model for direct contact condensation was previously developed by Westinghouse using first principles. The model is believed to be an accurate description of the direct contact condensation process in the presence of non-condensable gases. The Westinghouse condensation suppression model is further revised by applying a more physical model. The revised condensation suppression model is thus implemented into the WCOBRA/TRAC-TF2 LOCA safety evaluation code for both 3-D module (COBRA-TF) and 1-D module (TRAC-PF1). Parametric study using the revised Westinghouse condensation suppression model is conducted. Additionally, the performance of non-condensable gases condensation suppression model is examined in the ACHILLES (ISP-25) separate effects test and LOFT L2-5 (ISP-13) integral effects test. (authors)

  14. IMPACT OF THE COLD END OPERATING CONDITIONS ON ENERGY EFFICIENCY OF THE STEAM POWER PLANTS

    Directory of Open Access Journals (Sweden)

    Slobodan Laković

    2010-01-01

    Full Text Available The conventional steam power plant working under the Rankine Cycle and the steam condenser as a heat sink and the steam boiler as a heat source have the same importance for the power plant operating process. Energy efficiency of the coal fired power plant strongly depends on its turbine-condenser system operation mode. For the given thermal power plant configuration, cooling water temperature or/and flow rate change generate alterations in the condenser pressure. Those changes have great influence on the energy efficiency of the plant. This paper focuses on the influence of the cooling water temperature and flow rate on the condenser performance, and thus on the specific heat rate of the coal fired plant and its energy efficiency. Reference plant is working under turbine-follow mode with an open cycle cooling system. Analysis is done using thermodynamic theory, in order to define heat load dependence on the cooling water temperature and flow rate. Having these correlations, for given cooling water temperature it is possible to determine optimal flow rate of the cooling water in order to achieve an optimal condensing pressure, and thus, optimal energy efficiency of the plant. Obtained results could be used as useful guidelines in improving existing power plants performances and also in design of the new power plants.

  15. Effect of flow velocity on the process of air-steam condensation in a vertical tube condenser

    Science.gov (United States)

    Havlík, Jan; Dlouhý, Tomáš

    2018-06-01

    This article describes the influence of flow velocity on the condensation process in a vertical tube. For the case of condensation in a vertical tube condenser, both the pure steam condensation process and the air-steam mixture condensation process were theoretically and experimentally analyzed. The influence of steam flow velocity on the value of the heat transfer coefficient during the condensation process was evaluated. For the condensation of pure steam, the influence of flow velocity on the value of the heat transfer coefficient begins to be seen at higher speeds, conversely, this effect is negligible at low values of steam velocity. On the other hand, for the air-steam mixture condensation, the influence of flow velocity must always be taken into account. The flow velocity affects the water vapor diffusion process through non-condensing air. The presence of air significantly reduces the value of the heat transfer coefficient. This drop in the heat transfer coefficient is significant at low velocities; on the contrary, the decrease is relatively small at high values of the velocity.

  16. [A study of different polishing techniques for amalgams and glass-cermet cement by scanning electron microscope (SEM)].

    Science.gov (United States)

    Kakaboura, A; Vougiouklakis, G; Argiri, G

    1989-01-01

    Finishing and polishing an amalgam restoration, is considered as an important and necessary step of the restorative procedure. Various polishing techniques have been recommended to success a smooth amalgam surface. The aim of this study was to investigate the influence of three different polishing treatments on the marginal integrity and surface smoothness of restorations made of three commercially available amalgams and a glass-cermet cement. The materials used were the amalgams, Amalcap (Vivadent), Dispersalloy (Johnson and Johnson), Duralloy (Degussa) and the glass-cermet Katac-Silver (ESPE). The occlusal surfaces of the restorations were polished by the methods: I) round bur, No4-rubber cup-zinc oxide paste in a small brush, II) round bur No 4-bur-brown, green and super green (Shofu) polishing cups and points successively and III) amalgam polishing bur of 12-blades-smooth amalgam polishing bur. Photographs from unpolished and polished surfaces of the restorations, were taken with scanning electron microscope, to evaluate the polishing techniques. An improvement of marginal integrity and surface smoothness of all amalgam restorations was observed after the specimens had been polished with the three techniques. Method II, included Shofu polishers, proved the best results in comparison to the methods I and III. Polishing of glass-cermet cement was impossible with the examined techniques.

  17. Adaptation of the ORTHO-15 test to Polish women and men.

    Science.gov (United States)

    Brytek-Matera, Anna; Krupa, Magdalena; Poggiogalle, Eleonora; Donini, Lorenzo Maria

    2014-03-01

    There is a lack of Polish tools to measure behaviour related to orthorexia nervosa. The purpose of the present study was to validate the Polish version of the ORTHO-15 test. 341 women and 59 men (N = 400) were recruited, whose age ranged from 18 to 35 years. Mean age was 23.09 years (SD = 3.14) in women and 24.02 years (SD = 3.87) in men. The ORTHO-15 test and the EAT-26 test were used in the present study. Factor analysis (exploratory and confirmatory analysis) was used in the present study. Exploratory factor analysis performed on the initial 15 items from a random split half of the study group suggested a nine-item two-factor structure. Confirmatory factor analysis performed on the second randomly selected half of the study group supported this two-factor structure of the ORTHO-15 test. The Polish version of the ORTHO-15 test demonstrated an internal consistency (Cronbach's alpha) equal to 0.644. The Polish version of the ORTHO-15 test is a reliable and valuable instrument to assess obsessive attitudes related to healthy and proper nutrition in Polish female and male population.

  18. Gloss and surface roughness produced by polishing kits on resin composites.

    Science.gov (United States)

    Sadidzadeh, Ramtin; Cakir, Deniz; Ramp, Lance C; Burgess, John O

    2010-08-01

    To compare in vitro the surface roughness (Ra) and gloss (G) produced by three conventional and one experimental polishing kits on four resin composites. 24 discs were prepared (d = 12 mm, t = 4 mm) for each resin composite: Filtek Supreme Plus Body/A2 (FSB), Yellow Translucent (FST), Heliomolar/A2 (HM), and EsthetX/A2 (EX) following the manufacturers' instructions. They were finished with 320 grit silicon carbide paper for 80 seconds each. Polishing systems: Sof-Lex, Enhance-Pogo, Astropol and Experimental Discs/EXL-695, were applied following manufacturers' instructions. Each specimen was ultrasonically cleaned with distilled water and dried. Gloss and Ra were measured with a small area glossmeter (Novo-curve) and non-contact profilometer (Proscan 2000) following ISO 4288, respectively. The results were evaluated by two-way ANOVA followed by separate one-way ANOVA and Tukey/Kramer test (P = 0.05). There was a significant interaction of surface roughness and gloss between the composites and polishing systems (P gloss was obtained for FSB composite polished with the Experimental kit. The experimental polishing system produced smoothest surfaces (P gloss (P < 0.05).

  19. [Adhesion of oral microorganisms on dental porcelain polished and glazed].

    Science.gov (United States)

    Wang, Yi-ning; Wen, Guo-jiang; Shi, Bin; Pan, Xin-hua

    2003-09-01

    This study compared the roughness of porcelain polished or glazed surfaces and the adhesion of oral streptococcus mutans to them in vitro. 30 porcelain samples were made. Porcelain samples in group A were polished with diamond paste. Porcelain samples were glazed in group B and were polished with Al2O3 (240#) bur in group C. Their roughness values were measured by profilometer. Standardized cell suspensions were incubated with test samples for one hour at 37 degrees C, then retained cells were counted by image analysis (percentage area of a microscopic field covered by cells). Roughness values of group A, B, C were respectively (0.1987 +/- 0.057) microm, (0.1990 +/- 0.091) microm, (0.4260 +/- 0.174) microm. There was no significantly difference between group A and group B. The roughness samples in group C were significantly rougher than that in the other groups. The amount of retained cells in group A, group B, group C was respectively (15.92 +/- 4.37)%, (16.39 +/- 6.31)% and (41.48 +/- 12.1)%. There was no significant difference between the cell adhesion on porcelain surface glazed and polished, but more bacteria adhered on the porcelain surface in group C. Porcelain surface polished treatment was clinically acceptable compared with its glazed. They all exhibited the least amount of bacteria adhesion. The more porcelain surface was rough, the more bacteria adhered on it.

  20. Electrochemical Polishing Applications and EIS of a Vitamin B4-Based Ionic Liquid

    International Nuclear Information System (INIS)

    Wixtrom, Alex I.; Buhler, Jessica E.; Reece, Charles E.; Abdel-Fattah, Tarek M.

    2013-01-01

    Modern particle accelerators require minimal interior surface roughness for Niobium superconducting radio frequency (SRF) cavities. Polishing of the Nb is currently achieved via electrochemical polishing with concentrated mixtures of sulfuric and hydrofluoric acids. This acid-based approach is effective at reducing the surface roughness to acceptable levels for SRF use, but due to acid-related hazards and extra costs (including safe disposal of used polishing solutions), an acid-free method would be preferable. This study focuses on an alternative electrochemical polishing method for Nb, using a novel ionic liquid solution containing choline chloride, also known as Vitamin B 4 (VB 4 ). Potentiostatic electrochemical impedance spectroscopy (EIS) was also performed on the VB4-based system. Nb polished using the VB4-based method was found to have a final surface roughness comparable to that achieved via the acid-based method, as assessed by atomic force microscopy (AFM). These findings indicate that acid-free VB 4 -based electrochemical polishing of Nb represents a promising replacement for acid-based methods of SRF cavity preparation

  1. Time-dependent protection of ground and polished Cu using graphene film

    International Nuclear Information System (INIS)

    Dong, Yuhua; Liu, Qingqing; Zhou, Qiong

    2015-01-01

    Highlights: • Graphene was deposited on polished and ground Cu sheets by CVD. • Graphene films provide better protection to polished Cu for short time. • Multilayer graphene films provide better protection for short time. - Abstract: Graphene was deposited on Cu sheets with different morphologies by chemical vapor deposition. Scanning electron microscopy (SEM) analysis indicated that the morphology of the Cu sheet affected the graphene film properties. Electrochemical impedance spectroscopy measurements showed that the graphene film did not effectively protect Cu against corrosion because of prolonged exposure to ionic environments (3.5 wt.% NaCl solution). For short durations, graphene films provided better protection to polished Cu than ground Cu. Prolonged electrolyte immersion of graphene-coated Cu samples showed that the graphene film from the polished Cu surface was detached more easily than that from ground Cu

  2. Effect of polishing time and pressure on quality characteristics of rice grain

    International Nuclear Information System (INIS)

    Karim, M.A.

    2002-01-01

    Since totally unpolished rice has poor cooking quality, a certain amount of polishing for the removal of the outermost bran layers is essential. To determine the best combination of polishing time and pressure with respect to obtaining optimum quantity/quality, the brown rice (head grains) of a rice strain 4048 was milled for 10, 20, 30 and 40 seconds against 1,2,3,4 and 5 lbs pressure in a Burrows McGill Polisher No. 3. the quality characteristics studied were: total milling recovery, head rice recovery, whiteness of milled rice, protein content of grain, grain length and bursting upon cooking. Both, total milled rice and head rice reduced while the whiteness of milled rice improved significantly with an increase in polishing time and or pressure. The protein content decreased gradually with an increase in time and pressure of milling but the effect was non significant. The cooked grain length increased with an increase in milling degree up to a stage, beyond which it declined. The increase in bursting of grains on cooking. A combination of 20 seconds polishing time with 2 lbs pressure or 20 seconds polishing time with 3 lbs pressure was found to be the best combination of obtaining the optimum quality as well as the quality of milled rice.(author)

  3. Condensation: the new deal; Condensation: la nouvelle donne

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-06-01

    The principle of condensation boilers is based on the recovery of the latent heat of the steam generated by the combustion of natural gas. This technology was introduced in France at the end of the 80's but failed in its promise because of the complexity of the equipments available at that time. Today, constructors' offer is more mature and reliable and the context has changed. This technology can conciliate three goals: a mastery of energy consumptions, the comfort of the user and the respect of environment. This meeting organized by the research center of Gaz de France (Cegibat), was a good opportunity to makes a status of the market of individual condensation systems in France and in Europe, to present the situation of this technology today and the 10 golden rules for the fitting and maintenance of individual condensation boilers, and to present some technical references, examples and results of today's offer. (J.S.)

  4. Full scaled tests of the KERENA trademark containment cooling condenser at the INKA test facility

    International Nuclear Information System (INIS)

    Leyer, Stephan; Maisberger, Fabian; Lineva, Natalia; Wagner, Thomas; Doll, Mathias; Herbst, Vasilli; Wich, Michael

    2010-01-01

    KERENA trademark is a medium-capacity boiling water reactor. It combines passive safety systems with active safety equipment of service-proven design. The passive systems utilize basic laws of physics, such as gravity and natural convection, enabling them to function without any power supply or actuation by instrumentation and control (I and C) equipment. They are designed to bring the plant to a safe and stable condition without the aid of active systems. Furthermore, the passive safety features partially replace the active systems, which reduces costs significantly and provides a safe, reliable and economically competitive plant design. At the new test facility at Karlstein called INKA (Integral Test Stand Karlstein), the key components of the KERENA trademark passive safety concept - the Emergency Condenser (EC), the Containment Cooling Condenser (CCC) and the passive core flooding system (PCFS) - are presently under full-scale testing,. Integral system tests will also be performed to show how the passive safety systems interact under various anticipated accident conditions and to demonstrate the ability of the passive systems to bring the plant to a safe and stable condition without the aid of active systems or actuation by I and C signals. The passive pressure pulse transmitter (PPPT) will be included in these integral tests. In this report the experimental setup and the first test results with the full scaled Containment Cooling Condenser will be described. (orig.)

  5. How to Investigate Polish Clusters’ Attractiveness for Inward FDI? Addressing Ambiguity Problem

    Directory of Open Access Journals (Sweden)

    Götz Marta

    2014-09-01

    Full Text Available The aim of the paper is to assess whether, and in what fashion, managers of Polish cluster organizations perceive the attractiveness of foreign direct investment in Polish clusters This research is exploratory and qualitative in nature. The complex nature of Polish clusters, which can benefit from and be competitively challenged by, FDI are identified and a conceptual framework for assessing that nature is proposed; specifically, research using the grounded theory method (GTM.

  6. Robotic Automation in Computer Controlled Polishing

    Science.gov (United States)

    Walker, D. D.; Yu, G.; Bibby, M.; Dunn, C.; Li, H.; Wu, Y.; Zheng, X.; Zhang, P.

    2016-02-01

    We first present a Case Study - the manufacture of 1.4 m prototype mirror-segments for the European Extremely Large Telescope, undertaken by the National Facility for Ultra Precision Surfaces, at the OpTIC facility operated by Glyndwr University. Scale-up to serial-manufacture demands delivery of a 1.4 m off-axis aspheric hexagonal segment with surface precision robots and computer numerically controlled ('CNC') polishing machines for optical fabrication. The objective was not to assess which is superior. Rather, it was to understand for the first time their complementary properties, leading us to operate them together as a unit, integrated in hardware and software. Three key areas are reported. First is the novel use of robots to automate currently-manual operations on CNC polishing machines, to improve work-throughput, mitigate risk of damage to parts, and reduce dependence on highly-skilled staff. Second is the use of robots to pre-process surfaces prior to CNC polishing, to reduce total process time. The third draws the threads together, describing our vision of the automated manufacturing cell, where the operator interacts at cell rather than machine level. This promises to deliver a step-change in end-to-end manufacturing times and costs, compared with either platform used on its own or, indeed, the state-of-the-art used elsewhere.

  7. Utilization of municipal wastewater for cooling in thermoelectric power plants: Evaluation of the combined cost of makeup water treatment and increased condenser fouling

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Michael E. [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Theregowda, Ranjani B. [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept of Civil and Mechanical Engineering; Safari, Iman [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Abbasian, Javad [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Arastoopour, Hamid [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Dzombak, David A. [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept of Civil and Mechanical Engineering; Hsieh, Ming-Kai [Tamkang Univ., Taipei (Taiwan). Waer Resources Management and Policy Research Center; Miller, David C. [National Energy Technology Lab. (NETL), Morgantown, WV (United States)

    2013-10-01

    A methodology is presented to calculate the total combined cost (TCC) of water sourcing, water treatment and condenser fouling in the recirculating cooling systems of thermoelectric power plants. The methodology is employed to evaluate the economic viability of using treated municipal wastewater (MWW) to replace the use of freshwater as makeup water to power plant cooling systems. Cost analyses are presented for a reference power plant and five different tertiary treatment scenarios to reduce the scaling tendencies of MWW. Results indicate that a 550 MW sub-critical coal fired power plant with a makeup water requirement of 29.3 ML/day has a TCC of $3.0 - 3.2 million/yr associated with the use of treated MWW for cooling. (All costs USD 2009). This translates to a freshwater conservation cost of $0.29/kL, which is considerably lower than that of dry air cooling technology, $1.5/kL, as well as the 2020 conservation cost target set by the U.S. Department of Energy, $0.74/kL. Results also show that if the available price of freshwater exceeds that of secondary-treated MWW by more than $0.13-0.14/kL, it can be economically advantageous to purchase secondary MWW and treat it for utilization in the recirculating cooling system of a thermoelectric power plant.

  8. ROUGHNESS ANALYSIS OF VARIOUSLY POLISHED NIOBIUM SURFACES

    Energy Technology Data Exchange (ETDEWEB)

    Ribeill, G.; Reece, C.

    2008-01-01

    Niobium superconducting radio frequency (SRF) cavities have gained widespread use in accelerator systems. It has been shown that surface roughness is a determining factor in the cavities’ effi ciency and maximum accelerating potential achievable through this technology. Irregularities in the surface can lead to spot heating, undesirable local electrical fi eld enhancement and electron multipacting. Surface quality is typically ensured through the use of acid etching in a Buffered Chemical Polish (BCP) bath and electropolishing (EP). In this study, the effects of these techniques on surface morphology have been investigated in depth. The surface of niobium samples polished using different combinations of these techniques has been characterized through atomic force microscopy (AFM) and stylus profi lometry across a range of length scales. The surface morphology was analyzed using spectral techniques to determine roughness and characteristic dimensions. Experimentation has shown that this method is a valuable tool that provides quantitative information about surface roughness at different length scales. It has demonstrated that light BCP pretreatment and lower electrolyte temperature favors a smoother electropolish. These results will allow for the design of a superior polishing process for niobium SRF cavities and therefore increased accelerator operating effi ciency and power.

  9. STUDY OF PLANT-WIDE CONTROL IMPLEMENTATION IN PRODUCTION PROCESS OF GEOTHERMAL POWER PLANT

    Directory of Open Access Journals (Sweden)

    KATHERIN INDRIAWATI

    2017-02-01

    Full Text Available The design of plant-wide control system to optimize electricity production in geothermal power plant is proposed in this research. The objective is to overcome the deficiency due to changes in the characteristics of production well and fluctuation in electricity demand load. The proposed plant-wide control system has two main tasks; to maintain production process at optimum value and to increase efficiency. The pressure in separator and condenser is maintained at the respective set points under electrical load fluctuations in order to ensure optimum efficiency. The control system also reduce the usage of auxialiary electrical power and increase efficiency. The task was performed by controlling inlet cooling water temperatures to the condenser. It was concluded that the proposed control structure was able to increase efficiency and maintain production.

  10. Multi-objective optimization of circular magnetic abrasive polishing of SUS304 and Cu materials

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, NhatTan; Yin, ShaoHui; Chen, FengJun; Yin, HanFeng [Hunan University, Changsha (China); Pham, VanThoan [Hanoi University, Hanoi (Viet Nam); Tran, TrongNhan [Industrial University of Ho Chi Minh City, HCM City (Viet Nam)

    2016-06-15

    In this paper, a Multi-objective particle swarm optimization algorithm (MOPSOA) is applied to optimize surface roughness of workpiece after circular magnetic abrasive polishing. The most important parameters of polishing model, namely current, gap between pole and workpiece, spindle speed and polishing time, were considered in this approach. The objective functions of the MOPSOA depend on the quality of surface roughness of polishing materials with both simultaneous surfaces (Ra1, Ra2), which are determined by means of experimental approach with the aid of circular magnetic field. Finally, the effectiveness of the approach is compared between the optimal results with the experimental data. The results show that the new proposed polishing optimization method is more feasible.

  11. Etymology in the Polish Academy of Sciences Great Dictionary of ...

    African Journals Online (AJOL)

    The article offers an insight into etymological information provided in the Polish Academy of Sciences Great Dictionary of Polish (Pol. Wielki słownik języka polskiego PAN, WSJP PAN). The dictionary and the rules of producing the entries are briefly presented. These rules influence the way of working on etymology within ...

  12. Antecedents of Accelerated Internationalisation of Polish and Czech Small and Medium-Sized Enterprises

    Directory of Open Access Journals (Sweden)

    Izabela Kowalik

    2017-09-01

    Full Text Available Objective: The study goal was the investigation of relationships between accelerated internationalisation descriptors and antecedent firm- and entrepreneur-related factors in Polish and Czech SMEs. Research Design & Methods: In order to compare Polish and Czech companies, the data collected in two independent studies were used. The study of 233 Polish companies was conducted with the use of CATI method in 2014; 108 Czech companies were surveyed in 2013/2014 with the use of CAWI method. In both samples half of the surveyed SME-exporters were conforming to the accelerated internationalisation criteria. Findings: In both samples the “global vision” elements and company internationalisation scale and speed were interrelated. In the Polish companies this relationship was moderated by company size. There was the lack of strong positive relationships between innovativeness and internationalisation speed and scale in both samples. Implications & Recommendations:The managerial mindset has a decisive role for accelerated internationalisation in both Czech and Polish SMEs. The innovativeness of offering is not indispensable for fast foreign expansion. Larger companies may expand abroad faster if they have internationally oriented managers. Contribution & Value Added:This work addresses a research gap concerning idiosyncrasies of internationalisation antecedents in Polish and Czech enterprises. As the results show, there is no common internationalisation pattern for Polish and Czech SMEs.

  13. Effect of grinding and polishing on roughness and strength of zirconia.

    Science.gov (United States)

    Khayat, Waad; Chebib, Najla; Finkelman, Matthew; Khayat, Samer; Ali, Ala

    2018-04-01

    The clinical applications of high-translucency monolithic zirconia restorations have increased. Chairside and laboratory adjustments of these restorations are inevitable, which may lead to increased roughness and reduced strength. The influence of grinding and polishing on high-translucency zirconia has not been investigated. The purpose of this in vitro study was to compare the roughness averages (Ra) of ground and polished zirconia and investigate whether roughness influenced strength after aging. High-translucency zirconia disks were milled, sintered, and glazed according to the manufacturer's recommendations. Specimens were randomized to 4 equal groups. Group G received only grinding; groups GPB and GPK received grinding and polishing with different polishing systems; and group C was the (unground) control group. All specimens were subjected to hydrothermal aging in an autoclave at 134°C at 200 kPa for 3 hours. Roughness average was measured using a 3-dimensional (3D) optical interferometer at baseline (Ra1), after grinding and polishing (Ra2), and after aging (Ra3). A biaxial flexural strength test was performed at a rate of 0.5 mm/min. Statistical analyses were performed using commercial software (α=.05). Group G showed a significantly higher mean value of Ra3 (1.96 ±0.32 μm) than polished and glazed groups (P.05). Compared with baseline, the roughness of groups G and GPB increased significantly after surface treatments and after aging, whereas aging did not significantly influence the roughness of groups GPK or C. Group G showed the lowest mean value of biaxial flexural strength (879.01 ±157.99 MPa), and the highest value was achieved by group C (962.40 ±113.84 MPa); no statistically significant differences were found among groups (P>.05). Additionally, no significant correlation was detected between the Ra and flexural strength of zirconia. Grinding increased the roughness of zirconia restorations, whereas proper polishing resulted in smoothness

  14. Born-Kothari Condensation for Fermions

    Directory of Open Access Journals (Sweden)

    Arnab Ghosh

    2017-09-01

    Full Text Available In the spirit of Bose–Einstein condensation, we present a detailed account of the statistical description of the condensation phenomena for a Fermi–Dirac gas following the works of Born and Kothari. For bosons, while the condensed phase below a certain critical temperature, permits macroscopic occupation at the lowest energy single particle state, for fermions, due to Pauli exclusion principle, the condensed phase occurs only in the form of a single occupancy dense modes at the highest energy state. In spite of these rudimentary differences, our recent findings [Ghosh and Ray, 2017] identify the foregoing phenomenon as condensation-like coherence among fermions in an analogous way to Bose–Einstein condensate which is collectively described by a coherent matter wave. To reach the above conclusion, we employ the close relationship between the statistical methods of bosonic and fermionic fields pioneered by Cahill and Glauber. In addition to our previous results, we described in this mini-review that the highest momentum (energy for individual fermions, prerequisite for the condensation process, can be specified in terms of the natural length and energy scales of the problem. The existence of such condensed phases, which are of obvious significance in the context of elementary particles, have also been scrutinized.

  15. Condensation in Nanoporous Packed Beds.

    Science.gov (United States)

    Ally, Javed; Molla, Shahnawaz; Mostowfi, Farshid

    2016-05-10

    In materials with tiny, nanometer-scale pores, liquid condensation is shifted from the bulk saturation pressure observed at larger scales. This effect is called capillary condensation and can block pores, which has major consequences in hydrocarbon production, as well as in fuel cells, catalysis, and powder adhesion. In this study, high pressure nanofluidic condensation studies are performed using propane and carbon dioxide in a colloidal crystal packed bed. Direct visualization allows the extent of condensation to be observed, as well as inference of the pore geometry from Bragg diffraction. We show experimentally that capillary condensation depends on pore geometry and wettability because these factors determine the shape of the menisci that coalesce when pore filling occurs, contrary to the typical assumption that all pore structures can be modeled as cylindrical and perfectly wetting. We also observe capillary condensation at higher pressures than has been done previously, which is important because many applications involving this phenomenon occur well above atmospheric pressure, and there is little, if any, experimental validation of capillary condensation at such pressures, particularly with direct visualization.

  16. Comparison of Heat Transfer Coefficients of Silver Coated and Chromium Coated Copper Tubes of Condenser in Dropwise Condensation

    OpenAIRE

    Er. Shivesh Kumar; Dr. Amit Kumar

    2016-01-01

    Since centuries steam is being used in power generating system. The steam leaving the power unit is reconverted into water in a condenser designed to transfer heat from the steam to the cooling water as rapidly and as efficiently as possible. The efficiency of condenser depends on rate of condensation and mode of condensation of steam in the condenser. The increase in efficiency of the condenser enhances the heat transfer co-efficient which in turn results in economic design of condenser and ...

  17. Bio-oil fractionation and condensation

    Science.gov (United States)

    Brown, Robert C; Jones, Samuel T; Pollard, Anthony

    2013-07-02

    A method of fractionating bio-oil vapors which involves providing bio-oil vapors comprising bio-oil constituents is described. The bio-oil vapors are cooled in a first stage which comprises a condenser having passages for the bio-oil separated by a heat conducting wall from passages for a coolant. The coolant in the condenser of the first stage is maintained at a substantially constant temperature, set at a temperature in the range of 75 to 100.degree. C., to condense a first liquid fraction of liquefied bio-oil constituents in the condenser of the first stage. The first liquid fraction of liquified bio-oil constituents from the condenser in the first stage is collected. Also described are steps for subsequently recovering further liquid fractions of liquefied bio-oil constituents. Particular compositions of bio-oil condensation products are also described.

  18. Acoustic Emission Based In-process Monitoring in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo

    The applicability of acoustic emission (AE) measurements for in-process monitoring in the Robot Assisted Polishing (RAP) process was investigated. Surface roughness measurements require interruption of the process, proper surface cleaning and measurements that sometimes necessitate removal...... improving the efficiency of the process. It also allows for intelligent process control and generally enhances the robustness and reliability of the automated RAP system in industrial applications....... of the part from the machine tool. In this study, development of surface roughness during polishing rotational symmetric surfaces by the RAP process was inferred from AE measurements. An AE sensor was placed on a polishing tool, and a cylindrical rod of Vanadis 4E steel having an initial turned surface...

  19. Surface changes of metal alloys and high-strength ceramics after ultrasonic scaling and intraoral polishing.

    Science.gov (United States)

    Yoon, Hyung-In; Noh, Hyo-Mi; Park, Eun-Jin

    2017-06-01

    This study was to evaluate the effect of repeated ultrasonic scaling and surface polishing with intraoral polishing kits on the surface roughness of three different restorative materials. A total of 15 identical discs were fabricated with three different materials. The ultrasonic scaling was conducted for 20 seconds on the test surfaces. Subsequently, a multi-step polishing with recommended intraoral polishing kit was performed for 30 seconds. The 3D profiler and scanning electron microscopy were used to investigate surface integrity before scaling (pristine), after scaling, and after surface polishing for each material. Non-parametric Friedman and Wilcoxon signed rank sum tests were employed to statistically evaluate surface roughness changes of the pristine, scaled, and polished specimens. The level of significance was set at 0.05. Surface roughness values before scaling (pristine), after scaling, and polishing of the metal alloys were 3.02±0.34 µm, 2.44±0.72 µm, and 3.49±0.72 µm, respectively. Surface roughness of lithium disilicate increased from 2.35±1.05 µm (pristine) to 28.54±9.64 µm (scaling), and further increased after polishing (56.66±9.12 µm, P scaling (from 1.65±0.42 µm to 101.37±18.75 µm), while its surface roughness decreased after polishing (29.57±18.86 µm, P scaling significantly changed the surface integrities of lithium disilicate and zirconia. Surface polishing with multi-step intraoral kit after repeated scaling was only effective for the zirconia, while it was not for lithium disilicate.

  20. Condensation on superhydrophobic surfaces: the role of local energy barriers and structure length scale.

    Science.gov (United States)

    Enright, Ryan; Miljkovic, Nenad; Al-Obeidi, Ahmed; Thompson, Carl V; Wang, Evelyn N

    2012-10-09

    Water condensation on surfaces is a ubiquitous phase-change process that plays a crucial role in nature and across a range of industrial applications, including energy production, desalination, and environmental control. Nanotechnology has created opportunities to manipulate this process through the precise control of surface structure and chemistry, thus enabling the biomimicry of natural surfaces, such as the leaves of certain plant species, to realize superhydrophobic condensation. However, this "bottom-up" wetting process is inadequately described using typical global thermodynamic analyses and remains poorly understood. In this work, we elucidate, through imaging experiments on surfaces with structure length scales ranging from 100 nm to 10 μm and wetting physics, how local energy barriers are essential to understand non-equilibrium condensed droplet morphologies and demonstrate that overcoming these barriers via nucleation-mediated droplet-droplet interactions leads to the emergence of wetting states not predicted by scale-invariant global thermodynamic analysis. This mechanistic understanding offers insight into the role of surface-structure length scale, provides a quantitative basis for designing surfaces optimized for condensation in engineered systems, and promises insight into ice formation on surfaces that initiates with the condensation of subcooled water.

  1. Chromosome condensation and segmentation

    International Nuclear Information System (INIS)

    Viegas-Pequignot, E.M.

    1981-01-01

    Some aspects of chromosome condensation in mammalians -humans especially- were studied by means of cytogenetic techniques of chromosome banding. Two further approaches were adopted: a study of normal condensation as early as prophase, and an analysis of chromosome segmentation induced by physical (temperature and γ-rays) or chemical agents (base analogues, antibiotics, ...) in order to show out the factors liable to affect condensation. Here 'segmentation' means an abnormal chromosome condensation appearing systematically and being reproducible. The study of normal condensation was made possible by the development of a technique based on cell synchronization by thymidine and giving prophasic and prometaphasic cells. Besides, the possibility of inducing R-banding segmentations on these cells by BrdU (5-bromodeoxyuridine) allowed a much finer analysis of karyotypes. Another technique was developed using 5-ACR (5-azacytidine), it allowed to induce a segmentation similar to the one obtained using BrdU and identify heterochromatic areas rich in G-C bases pairs [fr

  2. Characteristic aspects of pion-condensed phases

    International Nuclear Information System (INIS)

    Takatsuka, Tatsuyuki; Tamagaki, Ryozo; Tatsumi, Toshitaka.

    1993-01-01

    Characteristic aspects of pion-condensed phases are described in a simple model, for the system involving only nucleons and pions which interact through the π-N P-wave interaction. We consider one typical version in each of three kinds of pion condensation; the one of neutral pions (π 0 ), the one of charged pions (π C ) and the combined one in which both the π 0 and π C condensations are coexistent. Emphasis is put on the description to clarify the novel structures of the nucleon system which are realized in the pion-condensed phases. At first, it is shown that the π 0 condensation is equivalent to the particular nucleonic phase realized by a structure change of the nucleon system, where the attractive first-order effect of the one-pion-exchange (OPE) tensor force is brought about coherently. The aspects of this phase are characterized by the layered structure with a specific spin-isospin order with one-dimensional localization (named the ALS structure in short), which provides the source function for the condensed π 0 field. We utilize both descriptions with use of fields and potentials for the π 0 condensation. Next, the π C condensation realized in neutron-rich matter is described by adopting a version of the traveling condensed wave. In this phase, the nucleonic structure becomes the Fermi gas consisting of quasi-neutrons described by a superposition of neutron and proton. In this sense the structure change of the nucleon system for the π C condensation is moderate, and the field description is suitable. Finally, we describe a coexistent pion condensation, in which both the π 0 and π C condensations coexist without interference in such a manner that the π C condensation develops in the ALS structure. The model adopted here provides us with the characteristic aspects of the pion-condensed phases persisting in the realistic situation, where other ingredients affecting the pion condensation are taken into account. (author)

  3. Systematic text condensation

    DEFF Research Database (Denmark)

    Malterud, Kirsti

    2012-01-01

    To present background, principles, and procedures for a strategy for qualitative analysis called systematic text condensation and discuss this approach compared with related strategies.......To present background, principles, and procedures for a strategy for qualitative analysis called systematic text condensation and discuss this approach compared with related strategies....

  4. Social Interest in The Polish Doctrine of Monument Preservation

    Science.gov (United States)

    Antoszczyszyn, Marek

    2017-10-01

    The paper discusses a controversy surrounding the latest amendment to the text of the Polish Parliament Act Conservation and the Care of Monuments (2015). It is a common dictum that any edifice cannot exist without good foundations. In this particular case of the mentioned above Act, definition of monument appears to be such a basis. A social interest is one of the constituent elements of the definition mentioned above. In the first part of the paper the notion of the social interest expression has been discussed, particularly from national and international points of view. The second part of the paper comprises some examples from the Polish monument preservation experience with the use of comparison method supported by case study. Only three big Polish cities: Warsaw, Wroclaw and Szczecin are involved in the presented case study but it must be emphasized that many other places on Polish territory experienced the same. Basing on the faith of these cities, the results and discussion chapter proves fundamental discrepancy in social interest notion between national and international scopes using some analytical methods. Finally, in the discussion chapter some proposals for the future amendment of monument definition in the Act of Conservation and the Care of Monuments have been provided.

  5. Scope of Nursing Care in Polish Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Mariusz Wysokiński

    2013-01-01

    Full Text Available Introduction. The TISS-28 scale, which may be used for nursing staff scheduling in ICU, does not reflect the complete scope of nursing resulting from varied cultural and organizational conditions of individual systems of health care. Aim. The objective of the study was an attempt to provide an answer to the question what scope of nursing care provided by Polish nurses in ICU does the TISS-28 scale reflect? Material and Methods. The methods of working time measurement were used in the study. For the needs of the study, 252 hours of continuous observation (day-long observation and 3.697 time-schedule measurements were carried out. Results. The total nursing time was 4125.79 min. (68.76 hours, that is, 60.15% of the total working time of Polish nurses during the period analyzed. Based on the median test, the difference was observed on the level of χ2=16945.8, P<0.001 between the nurses’ workload resulting from performance of activities qualified into the TISS-28 scale and load resulting from performance of interventions within the scopes of care not considered in this scale in Polish ICUs. Conclusions. The original version of the TISS-28 scale does not fully reflect the workload among Polish nurses employed in ICUs.

  6. Polish Qualitative Sociology. Insight into the future of postdisciplinary research

    OpenAIRE

    Konecki, Krzysztof

    2014-01-01

    The paper desctibes the definitions of following concepts: multidisiplinarity, interdisciplinarity, transdysciplinarity, postdisciplinarity. MOreover it discuss the meanings of a concept of discipline. It describes the place of the Polish qualitative sociology in the context of postdisciplinary research. The main question of paper is: Does the POlish Qualitative Sociology has entered the postdisciplinary phase of research? DGS, UL Krzysztof Konecki

  7. Surface roughness of microparticulated and nanoparticulated composites after finishing and polishing procedures

    Directory of Open Access Journals (Sweden)

    Rosemary Arai Sadami Shinkai

    Full Text Available Objective: To evaluated the surface roughness of one microparticulate resin composite Durafill (Heraeus Kulzer Weihrheim, Germany andfour nanoparticulate resins 4 Seasons (Ivoclar Vivadent, Schaan, Liechtenstein Esthet x (Dentsply, Milford, DE, USA, Point 4 and Supreme (3M-ESPE, Dental Products,St. Paul, MN, USA. Methods: After finishing with a diamond bur point (F, and polishing with silicone points of gray, green and pink color Politipit (Ivoclar Vivadent,Schaan, Liechtenstein, four stages of completion were performed, simulating one of finishing and three of polishing a resin restoration. Ten samples of each composite resin were measured for surface roughness with surface profilometer (Mitutoyo Corporation, Tokyo, Japan after each of finishing and polishing sequence.Results: The results showed that nanoparticulate and microparticulate resins presented a significant difference in the surface roughness values, in all finishing and polishing steps. Conclusion: Of the the nanoparticulate resins 4 Seasons (Ivoclar Vivadent, Schaan, Liechtenstein, Point 4 (Kerr CO, Orange, CA, USA, and also microparticulate Durafill (Heraeus Kulzer Weihrheim, Germany presented significantly lower surface roughness values after completing all the finishing and polishing stages.

  8. Precision machining and polishing of scintillating crystals for large calorimeters and hodoscopes

    International Nuclear Information System (INIS)

    Wuest, C.R.; Fuchs, B.A.; Holdener, F.R.; Heck, J.L. Jr.

    1994-04-01

    New machining and polishing techniques have been developed for large scintillating crystal arrays such as the Barium Fluoride Electromagnetic Calorimeter for the GEM Detector at SSCL, the Crystal Clear Collaboration's cerium fluoride or lead tungstenate calorimeter at the proposed LHC and CERN, the PHENIX Detector at RHIC (barium fluoride), and the cesium iodide Calorimeter for the BaBar Detector at PEP-2 B Factory at SLAC. The machining and polishing methods to be presented in this paper provide crystalline surfaces without sub-surface damage or deformation as verified by Rutherford Back-scattering (RBS) analysis. Surface roughness of about 10--20 angstroms and sub-micron mechanical tolerances have been demonstrated on large barium fluoride crystal samples. Mass production techniques have also been developed for machining the proper angled surfaces and polishing up to five 50 cm long crystals at one time. These techniques utilize kinematic mount technology developed at LLNL to allow precision machining and polishing of complex surfaces. They will present this technology along with detailed surface studies of barium fluoride and cerium fluoride crystals polished with this technique

  9. The status of the Bubbler Condenser Containment System for the Reactors of the VVER-440/213 Type

    International Nuclear Information System (INIS)

    Karwat, H.; Rosinger, H.E.

    1998-01-01

    VVER-440/213 Pressurized Water Reactors have a pressure-suppression containment structure called a 'Bubbler Condenser' tower which can reduce the design pressure of the entire containment following a design basis accident (DBA), such as a loss-of-coolant accident (LOCA). The bubbler condenser pressure suppression system provides reduction of the LOCA containment pressure by the condensation of released steam in a water pool. World-wide there are 14 nuclear power plants of the VVER-440/213 type in Eastern Europe and Russia. One of the safety concerns for the VVER-440/213 reactors relates to the ability of the bubbler condenser containment system to function satisfactorily and to maintain its integrity following certain postulated accidents and thus limit the release of radioactive material to the environment. The complicated geometry of the bubbler condenser unit, and the dependence on several moving devices and interlocks are the main doubts expressed by different specialists with regard to the design. General description of the bubbler condenser containment system, the physical processes, concerns and design assessment of the bubbler condenser containment system, presentation of the OECD's Unified Bubbler Condenser Research Project (UBCRP) and the European Commission PHARE/TACIS project. Recent utility investigations are also discussed

  10. Steam generators, turbines, and condensers. Volume six

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Volume six covers steam generators (How steam is generated, steam generation in a PWR, vertical U-tube steam generators, once-through steam generators, how much steam do steam generators make?), turbines (basic turbine principles, impulse turbines, reaction turbines, turbine stages, turbine arrangements, turbine steam flow, steam admission to turbines, turbine seals and supports, turbine oil system, generators), and condensers (need for condensers, basic condenser principles, condenser arrangements, heat transfer in condensers, air removal from condensers, circulating water system, heat loss to the circulating water system, factors affecting condenser performance, condenser auxiliaries)

  11. Acoustic emission-based in-process monitoring of surface generation in robot-assisted polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo

    2016-01-01

    The applicability of acoustic emission (AE) measurements for in-process monitoring of surface generation in the robot-assisted polishing (RAP) was investigated. Surface roughness measurements require interruption of the process, proper surface cleaning and measurements that sometimes necessitate...... automatic detection of optimal process endpoint allow intelligent process control, creating fundamental elements in development of robust fully automated RAP process for its widespread industrial application....... removal of the part from the machine tool. In this study, stabilisation of surface roughness during polishing rotational symmetric surfaces by the RAP process was monitored by AE measurements. An AE sensor was placed on a polishing arm in direct contact with a bonded abrasive polishing tool...

  12. Effect of one-step polishing system on the color stability of nanocomposites.

    Science.gov (United States)

    Alawjali, S S; Lui, J L

    2013-08-01

    This study was to compare the effect of three different one-step polishing systems on the color stability of three different types of nanocomposites after immersion in coffee for one day and seven days and determine which nanocomposite material has the best color stability following polishing with each of the one-step polishing system. The nanocomposites tested were Tetric EvoCeram, Grandio and Herculite Précis. A total of 120 discs (40/nanocomposite, 8mm×2mm) were fabricated. Ten specimens for each nanocomposite cured under Mylar strips served as the control. The other specimens were polished with OptraPol, OneGloss and Occlubrush immersed in coffee (Nescafé) up to seven days. Color measurements were made with a spectrophotometer at baseline and after one and seven days. Two way repeated measure ANOVA, two way ANOVA and Bonferroni tests were used for statistical analyses (P<0.05). The immersion time was a significant factor in the discoloration of the nanocomposites. The effect of three one-step polishing systems on the color stability was also significant. The color change values of the materials cured against Mylar strips were the greatest. The lowest mean color change values were from the Occlubrush polished groups. The effect of the three different types of nanocomposite on the color change was significant. The highest color change values were with Tetric EvoCeram groups. The lowest color change values were with Herculite Précis groups. The color change of nanocomposite resins is affected by the type of composite, polishing procedure and the period of immersion in the staining agent. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Application of Evaporative Cooling for the Condensation of Water Vapors from a Flue Gas Waste Heat Boilers CCP

    Directory of Open Access Journals (Sweden)

    Galashov Nikolay

    2016-01-01

    Full Text Available The object of the study are boilers that burn organic fuel and the recovery boilers (RB of the combined cycle plant (CCP, which are al-so working on the products of the combustion of hydrocarbon fuels. The purpose of research is to find technologies that increase efficiency of the thermal power plant (TPP and technologies that reduce the environmental impact on the environment by burning fossil fuels. The paper deals with the technology of the boilers burning hydrocarbon fuel with condensation of water vapor from the exhaust flue gases. Considered the problems caused by using of this technology. Research shows that the main problem of this technology in the boilers is the lack of reliable methods of calculation of heat exchangers, condensers. Particular attention is paid to the application of this technology in the recovery boilers combined-cycle plants, which are currently gaining increasing use in the generation of electricity from the combustion of gas in power plants. It is shown that the application of technology of condensation of water vapor in RB CCP, the temperature decreases of exhaust gases from 100 to 40 °С, allows increasing the effi-ciency of the RB with 86.2 % to 99.5 %, i.e. at 12.3 %, and increase the ef-ficiency of the CCP at 2.8 %.

  14. Direct-contact condensers for open-cycle OTEC applications: Model validation with fresh water experiments for structured packings

    Energy Technology Data Exchange (ETDEWEB)

    Bharathan, D.; Parsons, B.K.; Althof, J.A.

    1988-10-01

    The objective of the reported work was to develop analytical methods for evaluating the design and performance of advanced high-performance heat exchangers for use in open-cycle thermal energy conversion (OC-OTEC) systems. This report describes the progress made on validating a one-dimensional, steady-state analytical computer of fresh water experiments. The condenser model represents the state of the art in direct-contact heat exchange for condensation for OC-OTEC applications. This is expected to provide a basis for optimizing OC-OTEC plant configurations. Using the model, we examined two condenser geometries, a cocurrent and a countercurrent configuration. This report provides detailed validation results for important condenser parameters for cocurrent and countercurrent flows. Based on the comparisons and uncertainty overlap between the experimental data and predictions, the model is shown to predict critical condenser performance parameters with an uncertainty acceptable for general engineering design and performance evaluations. 33 refs., 69 figs., 38 tabs.

  15. Evaluation of one-step micro polishers for residual resin removal after debonding on fluorosed teeth

    Directory of Open Access Journals (Sweden)

    Padmalatha Challa

    2014-01-01

    Full Text Available Aim and objectives: To evaluate the effectiveness of one step micro polishers for residual resin removal on fluorosed teeth using scanning electron microscope (SEM. Methods and Material: 55 teeth with mild to moderate fluorosis were selected with five teeth as control. Metal brackets were bonded onto 50 teeth which were divided into 5 groups. The finishing and polishing methods which were tested include tungsten carbide burs (TCB, multistep finishing system (Sof-Lex, one step polishers (PoGo and combination of TCB with multistep and one step polishing systems. After resin removal, all the samples were examined under SEM for assessment of the enamel surface. Results: The enamel surface was closest to untouched enamel in samples finished with the PoGo one step polishers followed by Sof-Lex multistep finishing system. However, they took the longest time to finish. TCB required the shortest time for residual resin removal. Conclusions: All polishing systems produce a certain degree of damage to the enamel surface with the smoothest surface being produced by one step polishers on fluorosed teeth.

  16. Power plant emissions reduction

    Science.gov (United States)

    Anand, Ashok Kumar; Nagarjuna Reddy, Thirumala Reddy

    2015-10-20

    A system for improved emissions performance of a power plant generally includes an exhaust gas recirculation system having an exhaust gas compressor disposed downstream from the combustor, a condensation collection system at least partially disposed upstream from the exhaust gas compressor, and a mixing chamber in fluid communication with the exhaust gas compressor and the condensation collection system, where the mixing chamber is in fluid communication with the combustor.

  17. Enhancement of LNG plant propane cycle through waste heat powered absorption cooling

    International Nuclear Information System (INIS)

    Rodgers, P.; Mortazavi, A.; Eveloy, V.; Al-Hashimi, S.; Hwang, Y.; Radermacher, R.

    2012-01-01

    In liquefied natural gas (LNG) plants utilizing sea water for process cooling, both the efficiency and production capacity of the propane cycle decrease with increasing sea water temperature. To address this issue, several propane cycle enhancement approaches are investigated in this study, which require minimal modification of the existing plant configuration. These approaches rely on the use of gas turbine waste heat powered water/lithium bromide absorption cooling to either (i) subcool propane after the propane cycle condenser, or (ii) reduce propane cycle condensing pressure through pre-cooling of condenser cooling water. In the second approach, two alternative methods of pre-cooling condenser cooling water are considered, which consist of an open sea water loop, and a closed fresh water loop. In addition for all cases, three candidate absorption chiller configurations are evaluated, namely single-effect, double-effect, and cascaded double- and single-effect chillers. The thermodynamic performance of each propane cycle enhancement scheme, integrated in an actual LNG plant in the Persian Gulf, is evaluated using actual plant operating data. Subcooling propane after the propane cycle condenser is found to improve propane cycle total coefficient of performance (COP T ) and cooling capacity by 13% and 23%, respectively. The necessary cooling load could be provided by either a single-effect, double-effect or cascaded and single- and double-effect absorption refrigeration cycle recovering waste heat from a single gas turbine operated at full load. Reducing propane condensing pressure using a closed fresh water condenser cooling loop is found result in propane cycle COP T and cooling capacity enhancements of 63% and 22%, respectively, but would require substantially higher capital investment than for propane subcooling, due to higher cooling load and thus higher waste heat requirements. Considering the present trend of short process enhancement payback periods in the

  18. Assessment of horizontal in-tube condensation models using MARS code. Part I: Stratified flow condensation

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Seong-Su [Department of Engineering Project, FNC Technology Co., Ltd., Bldg. 135-308, Seoul National University, Gwanak-gu, Seoul 151-744 (Korea, Republic of); Department of Nuclear Engineering, Seoul National University, Gwanak-gu, Seoul 151-744 (Korea, Republic of); Hong, Soon-Joon, E-mail: sjhong90@fnctech.com [Department of Engineering Project, FNC Technology Co., Ltd., Bldg. 135-308, Seoul National University, Gwanak-gu, Seoul 151-744 (Korea, Republic of); Park, Ju-Yeop; Seul, Kwang-Won [Korea Institute of Nuclear Safety, 19 Kuseong-dong, Yuseong-gu, Daejon (Korea, Republic of); Park, Goon-Cherl [Department of Nuclear Engineering, Seoul National University, Gwanak-gu, Seoul 151-744 (Korea, Republic of)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer This study collected 11 horizontal in-tube condensation models for stratified flow. Black-Right-Pointing-Pointer This study assessed the predictive capability of the models for steam condensation. Black-Right-Pointing-Pointer Purdue-PCCS experiments were simulated using MARS code incorporated with models. Black-Right-Pointing-Pointer Cavallini et al. (2006) model predicts well the data for stratified flow condition. Black-Right-Pointing-Pointer Results of this study can be used to improve condensation model in RELAP5 or MARS. - Abstract: The accurate prediction of the horizontal in-tube condensation heat transfer is a primary concern in the optimum design and safety analysis of horizontal heat exchangers of passive safety systems such as the passive containment cooling system (PCCS), the emergency condenser system (ECS) and the passive auxiliary feed-water system (PAFS). It is essential to analyze and assess the predictive capability of the previous horizontal in-tube condensation models for each flow regime using various experimental data. This study assessed totally 11 condensation models for the stratified flow, one of the main flow regime encountered in the horizontal condenser, with the heat transfer data from the Purdue-PCCS experiment using the multi-dimensional analysis of reactor safety (MARS) code. From the assessments, it was found that the models by Akers and Rosson, Chato, Tandon et al., Sweeney and Chato, and Cavallini et al. (2002) under-predicted the data in the main condensation heat transfer region, on the contrary to this, the models by Rosson and Meyers, Jaster and Kosky, Fujii, Dobson and Chato, and Thome et al. similarly- or over-predicted the data, and especially, Cavallini et al. (2006) model shows good predictive capability for all test conditions. The results of this study can be used importantly to improve the condensation models in thermal hydraulic code, such as RELAP5 or MARS code.

  19. Bioaccumulation of Aluminium in Hydromacrophytes in Polish Coastal Lakes

    Directory of Open Access Journals (Sweden)

    Senze Magdalena

    2015-03-01

    Full Text Available The research on aluminium content was conducted in water and on aquatic flora of Polish lakes in the central part of the coast. The study included the lakes Sarbsko, Choczewskie, Bia.e, K.odno, D.brze and Salino investigated in the summer of 2013. The examined lakes belong mainly to the direct basin of the Baltic Sea. Samples of aquatic plants and lake waters were collected. In the water samples pH and electrolytic conductivity were measured. The aluminium content was determined both in water and aquatic plants. Submerged hydromacrophyte studies included Myriophyllum alterniflorum L., Potamogeton perfoliatus L. and Ceratophyllum demersum L. Emergent hydromacrophyte studies included Phragmites australis (Cav. Trin. ex Steud., Juncus bulbosus L., Iris pseudacorus L., Eleocharis palustris (L. Roem. % Schult., Phalaris arundinacea L., Carex riparia Curt., Mentha aquatic L., Stratiotes aloides L., Alisma plantago-aquatica L., Glyceria maxima (Hartman Holmb., Sagittaria sagittifolia L., Scirpus lacustris L. and Typha angustifolia L. The purpose of this investigation was the determination of the aluminium content in submerged and emergent hydromacrophytes and also the definition of their bioaccumulative abilities. The average concentration of aluminium in water was 2.68 fęg Al dm.3. The average content of aluminium in plants was 2.8015 mg Al kg.1. The bioaccumulation factor ranged from BCF=19.74 to BCF=16619. On the basis of the analysis of the aluminium content in water and aquatic plants results show that both water and plants were characterized by a moderate level of aluminium. The recorded concentrations indicate a mid-range value and are much lower than those which are quoted for a variety of surface waters in various parts of the world.

  20. Superhydrophobicity of biological and technical surfaces under moisture condensation: stability in relation to surface structure.

    Science.gov (United States)

    Mockenhaupt, Bernd; Ensikat, Hans-Jürgen; Spaeth, Manuel; Barthlott, Wilhelm

    2008-12-02

    The stability of superhydrophobic properties of eight plants and four technical surfaces in respect to water condensation has been compared. Contact and sliding angles were measured after application of water drops of ambient temperature (20 degrees C) onto cooled surfaces. Water evaporating from the drops condensed, due to the temperature difference between the drops and the surface, on the cooled samples, forming "satellite droplets" in the vicinity of the drops. Surface cooling to 15, 10, and 5 degrees C showed a gradual decrease of superhydrophobicity. The decrease was dependent on the specific surface architecture of the sample. The least decrease was found on hierarchically structured surfaces with a combination of a coarse microstructure and submicrometer-sized structures, similar to that of the Lotus leaf. Control experiments with glycerol droplets, which show no evaporation, and thus no condensation, were carried out to verify that the effects with water were caused by condensation from the drop (secondary condensation). Furthermore, the superhydrophobic properties after condensation on cooled surfaces from a humid environment for 10 min were examined. After this period, the surfaces were covered with spherical water droplets, but most samples retained their superhydrophobicity. Again, the best stability of the water-repellent properties was found on hierarchically structured surfaces similar to that of the Lotus leaf.