UOBPRM: A uniformly distributed obstacle-based PRM
Yeh, Hsin-Yi
2012-10-01
This paper presents a new sampling method for motion planning that can generate configurations more uniformly distributed on C-obstacle surfaces than prior approaches. Here, roadmap nodes are generated from the intersections between C-obstacles and a set of uniformly distributed fixed-length segments in C-space. The results show that this new sampling method yields samples that are more uniformly distributed than previous obstacle-based methods such as OBPRM, Gaussian sampling, and Bridge test sampling. UOBPRM is shown to have nodes more uniformly distributed near C-obstacle surfaces and also requires the fewest nodes and edges to solve challenging motion planning problems with varying narrow passages. © 2012 IEEE.
Determining irrigation distribution uniformity and efficiency for nurseries
R. Thomas Fernandez
2010-01-01
A simple method for testing the distribution uniformity of overhead irrigation systems is described. The procedure is described step-by-step along with an example. Other uses of distribution uniformity testing are presented, as well as common situations that affect distribution uniformity and how to alleviate them.
Impact of uniform electrode current distribution on ETF
Bents, D. J.
1982-01-01
The design impacts on the ETF electrode consolidation network associated with uniform channel electrode current distribution are examined and the alternate consolidation design which occur are presented compared to the baseline (non-uniform current) design with respect to performance, and hardware requirements. A rational basis is given for comparing the requirements for the different designs and the savings that result from uniform current distribution. Performance and cost impacts upon the combined cycle plant are discussed.
Measurement of fuel importance distribution in non-uniformly distributed fuel systems
International Nuclear Information System (INIS)
Yamane, Yoshihiro; Hirano, Yasushi; Yasui, Hazime; Izima, Kazunori; Shiroya, Seiji; Kobayashi, Keiji.
1995-01-01
A reactivity effect due to a spatial variation of nuclear fuel concentration is an important problem for nuclear criticality safety in a reprocessing plant. As a theory estimating this reactivity effect, the Goertzel and fuel importance theories are well known. It has been shown that the Goertzel's theory is valid in the range of our experiments based on measurements of reactivity effect and thermal neutron flux in non-uniformly distributed fuel systems. On the other hand, there have been no reports concerning systematic experimental studies on the flatness of fuel importance which is a more general index than the Goertzel's theory. It is derived from the perturbation theory that the fuel importance is proportional to the reactivity change resulting from a change of small amount of fuel mass. Using a uniform and three kinds of nonuniform fuel systems consisting of 93.2% enriched uranium plates and polyethylene plates, the fuel importance distributions were measured. As a result, it was found experimentally that the fuel importance distribution became flat, as its reactivity effect became large. Therefore it was concluded that the flatness of fuel importance distribution is the useful index for estimating reactivity effect of non-uniformly distributed fuel system. (author)
On a Generalisation of Uniform Distribution and its Properties
Directory of Open Access Journals (Sweden)
K. Jayakumar
2016-03-01
Full Text Available Nadarajah et al.(2013 introduced a family life time models using truncated negative binomial distribution and derived some properties of the family of distributions. It is a generalization of Marshall-Olkin family of distributions. In this paper, we introduce Generalized Uniform Distribution (GUD using the approach of Nadarajah et al.(2013. The shape properties of density function and hazard function are discussed. The expression for moments, order statistics, entropies are obtained. Estimation procedure is also discussed.The GDU introduced here is a generalization of the Marshall-Olkin extended uniform distribution studied in Jose and Krishna(2011.
On the burnout in annular channels at non-uniform heat release distribution in length
International Nuclear Information System (INIS)
Ornatskij, A.P.; Chernobaj, V.A.; Vasil'ev, A.F.; Struts, G.V.
1982-01-01
The effect of axial heat release non-uniformity on the conditions of the burnout in annular channels is investigated. The investigation is carried out in annular channels with different laws of heat flux density distribution by channel length. The heat release non-uniformity coefficient was varied from 4.4 to 10, the pressure from 9.8 to 17.6 MPa, mass rate from 500 to 1700 kg (m 2 xS), liquid temperature (chemically desalted water) at the channel inlet constituted 30-300 deg C. The experiments have been performed at the test bench with a closed circulation circuit. The data obtained testify to the fact that under non-uniform heat release the influence of main operating parameters on the value of critical power is of the same character as under uniform heat release. The character of wall temperature variation by channel length before the burnout is determined by the form of heat supply temperature profile. The temperature maximum is observed in the region lying behind the cross section with maximum heat flux. The conclusion is drawn that the dominant influence on the position of the cross section in which the burnout arises is exerted by the form of heat flux density distribution by length. Independently of this distribution form the burnout developes when the vapour content near the wall reaches a limiting value
UOBPRM: A uniformly distributed obstacle-based PRM
Yeh, Hsin-Yi; Thomas, Shawna; Eppstein, David; Amato, Nancy M.
2012-01-01
This paper presents a new sampling method for motion planning that can generate configurations more uniformly distributed on C-obstacle surfaces than prior approaches. Here, roadmap nodes are generated from the intersections between C
Effect of sprinkler structure on water distribution uniformity
International Nuclear Information System (INIS)
Xu, M; Li, H; Chen, C; Tu, Q; Liu, J P
2012-01-01
Structures of sprinklers play important roles in the uniformity of water distribution. The advances and achievements to improve the distribution uniformity through the innovation in the sprinkler structures at home and abroad were presented in details. Analyses showed that three types of structure can ameliorate the water distribution efficiently. First, novel nozzle structures were applied, including the application of non-circle nozzle and special spread nozzles. Second, new structures of flow channel were used. Third, assistant device was added so as to improve the uneven water distribution, such as an assistant stream interrupter, pressure or flow rate regulator and so on. Compared to domestic sprinklers, sprinklers produced abroad have novel and special structures with better hydraulic performance. Basic theoretical researches should be strengthened and new materials, new manufacturing processes and new technique should be applied. Then new kinds of sprinkler will be produced and the hydraulic performance of sprinklers will be promoted to a higher level.
Impact of uniform electrode current distribution on ETF. [Engineering Test Facility MHD generator
Bents, D. J.
1982-01-01
A basic reason for the complexity and sheer volume of electrode consolidation hardware in the MHD ETF Powertrain system is the channel electrode current distribution, which is non-uniform. If the channel design is altered to provide uniform electrode current distribution, the amount of hardware required decreases considerably, but at the possible expense of degraded channel performance. This paper explains the design impacts on the ETF electrode consolidation network associated with uniform channel electrode current distribution, and presents the alternate consolidation designs which occur. They are compared to the baseline (non-uniform current) design with respect to performance, and hardware requirements. A rational basis is presented for comparing the requirements for the different designs and the savings that result from uniform current distribution. Performance and cost impacts upon the combined cycle plant are discussed.
Modeling of parallel-plate regenerators with non-uniform plate distributions
DEFF Research Database (Denmark)
Jensen, Jesper Buch; Engelbrecht, Kurt; Bahl, Christian Robert Haffenden
2010-01-01
plate spacing distributions are presented in order to understand the impact of spacing non-uniformity. Simulations of more realistic distributions where the plate spacings follow normal distributions are then discussed in order to describe the deviation of the performance of a regenerator relative...
Directory of Open Access Journals (Sweden)
X. Ning
2012-08-01
To resolve the above-mentioned registration difficulties, a parallel and adaptive uniform-distributed registration method for CE-1 lunar remote sensed imagery is proposed in this paper. Based on 6 pairs of randomly selected images, both the standard SIFT algorithm and the parallel and adaptive uniform-distributed registration method were executed, the versatility and effectiveness were assessed. The experimental results indicate that: by applying the parallel and adaptive uniform-distributed registration method, the efficiency of CE-1 lunar remote sensed imagery registration were increased dramatically. Therefore, the proposed method in the paper could acquire uniform-distributed registration results more effectively, the registration difficulties including difficult to obtain results, time-consuming, non-uniform distribution could be successfully solved.
Curved-straight neutron guide system with uniform spatial intensity distribution
International Nuclear Information System (INIS)
Mildner, D.F.R.; Cook, J.C.
2008-01-01
The spatial intensity distribution of neutrons emerging from a curved guide is asymmetric, and straight guide sections are sometimes appended to curved guides to make the intensity distribution more nearly uniform. For idealized uniform illumination and in the perfect reflectivity approximation, the spatial-angular acceptance at the exit of the combination can be made exactly uniform for a range of long wavelengths by using a sufficiently long straight section, together with a curved guide whose outer wall coating has a critical angle slightly greater than those of the other guide walls. We refer to this as a 'phase space tailoring guide' where the coatings on the inner wall and straight section are used to define the required divergence at the end of the guide. Increasing the critical angle of the outer wall of the curved section reduces the characteristic wavelength of the curved guide as well as the wavelength at which ideal uniformity can be obtained. The outer wall coating need only be of sufficiently high critical angle to fill the transmittable phase space area of the straight guide uniformly to adequately short wavelength
Study of the distribution of maxima and minima in multiple sequential images of uniformity
International Nuclear Information System (INIS)
Llacer Martos, S.; Puchal Ane, R.
2011-01-01
To characterize the uniformity of a gamma camera extrinsic used integral uniformity coefficient is calculated with the value of two pixels, the maximum and minimum, single source acquisition of a flat and uniform. This method does not take into account the fact that if a gamma camera having a uniform response, the distribution of these items should be random. In this paper we study how these points are distributed in a succession of large numbers of uniform images.
Tumour control probability (TCP) for non-uniform activity distribution in radionuclide therapy
International Nuclear Information System (INIS)
Uusijaervi, Helena; Bernhardt, Peter; Forssell-Aronsson, Eva
2008-01-01
Non-uniform radionuclide distribution in tumours will lead to a non-uniform absorbed dose. The aim of this study was to investigate how tumour control probability (TCP) depends on the radionuclide distribution in the tumour, both macroscopically and at the subcellular level. The absorbed dose in the cell nuclei of tumours was calculated for 90 Y, 177 Lu, 103m Rh and 211 At. The radionuclides were uniformly distributed within the subcellular compartment and they were uniformly, normally or log-normally distributed among the cells in the tumour. When all cells contain the same amount of activity, the cumulated activities required for TCP = 0.99 (A-tilde TCP=0.99 ) were 1.5-2 and 2-3 times higher when the activity was distributed on the cell membrane compared to in the cell nucleus for 103m Rh and 211 At, respectively. TCP for 90 Y was not affected by different radionuclide distributions, whereas for 177 Lu, it was slightly affected when the radionuclide was in the nucleus. TCP for 103m Rh and 211 At were affected by different radionuclide distributions to a great extent when the radionuclides were in the cell nucleus and to lesser extents when the radionuclides were distributed on the cell membrane or in the cytoplasm. When the activity was distributed in the nucleus, A-tilde TCP=0.99 increased when the activity distribution became more heterogeneous for 103m Rh and 211 At, and the increase was large when the activity was normally distributed compared to log-normally distributed. When the activity was distributed on the cell membrane, A-tilde TCP=0.99 was not affected for 103m Rh and 211 At when the activity distribution became more heterogeneous. A-tilde TCP=0.99 for 90 Y and 177 Lu were not affected by different activity distributions, neither macroscopic nor subcellular
Problem of uniqueness in the renewal process generated by the uniform distribution
Directory of Open Access Journals (Sweden)
D. Ugrin-parac
1992-01-01
Full Text Available The renewal process generated by the uniform distribution, when interpreted as a transformation of the uniform distribution into a discrete distribution, gives rise to the question of uniqueness of the inverse image. The paper deals with a particular problem from the described domain, that arose in the construction of a complex stochastic test intended to evaluate pseudo-random number generators. The connection of the treated problem with the question of a unique integral representation of Gamma-function is also mentioned.
Continuous-variable quantum key distribution in uniform fast-fading channels
Papanastasiou, Panagiotis; Weedbrook, Christian; Pirandola, Stefano
2018-03-01
We investigate the performance of several continuous-variable quantum key distribution protocols in the presence of uniform fading channels. These are lossy channels whose transmissivity changes according to a uniform probability distribution. We assume the worst-case scenario where an eavesdropper induces a fast-fading process, where she chooses the instantaneous transmissivity while the remote parties may only detect the mean statistical effect. We analyze coherent-state protocols in various configurations, including the one-way switching protocol in reverse reconciliation, the measurement-device-independent protocol in the symmetric configuration, and its extension to a three-party network. We show that, regardless of the advantage given to the eavesdropper (control of the fading), these protocols can still achieve high rates under realistic attacks, within reasonable values for the variance of the probability distribution associated with the fading process.
Energy Technology Data Exchange (ETDEWEB)
Suphanit, B. [Department of Chemical Engineering, Faculty of Engineering, King Mongkut' s University of Technology Thonburi, Pracha Utit Rd., Tungkru, Bangkok 10140 (Thailand)
2010-03-15
The internally heat-integrated distillation column (HIDiC) is a complex column configuration which is more energy efficient than the equivalent conventional column or the distillation column with direct vapor recompression scheme (VRC). Exploiting the heat integration between two diabatic sections operating at different pressures of the HIDiC can greatly enhance the energy performance of the system. On the other hand, the design and optimization of HIDiC is more difficult than those of the conventional distillation column or the column with VRC. The former involves many design parameters, and the most critical one is the pressure ratio between both diabatic sections. However, the heat distribution along the diabatic sections is also another significant factor not yet thoroughly investigated. In this work, two typical distribution schemes, i.e. uniform heat transfer area and uniform heat distribution, are studied by applying a novel approach to solve the simulation problem in Aspen Plus 2004.1. The comparison of both distributing schemes is discussed via two widely-used case studies, namely benzene-toluene separation and propylene-propane splitter. (author)
Directory of Open Access Journals (Sweden)
Christopher Martinez
2007-02-01
Full Text Available Hashing algorithms long have been widely adopted to design a fast address look-up process which involves a search through a large database to find a record associated with a given key. Hashing algorithms involve transforming a key inside each target data to a hash value hoping that the hashing would render the database a uniform distribution with respect to this new hash value. The close the final distribution is to uniform, the less search time would be required when a query is made. When the database is already key-wise uniformly distributed, any regular hashing algorithm, such as bit-extraction, bit-group XOR, etc., would easily lead to a statistically perfect uniform distribution after the hashing. On the other hand, if records in the database are instead not uniformly distributed as in almost all known practical applications, then even different regular hash functions would lead to very different performance. When the target database has a key with a highly skewed distributed value, performance delivered by regular hashing algorithms usually becomes far from desirable. This paper aims at designing a hashing algorithm to achieve the highest probability in leading to a uniformly distributed hash result from a non-uniformly distributed database. An analytical pre-process on the original database is first performed to extract critical information that would significantly benefit the design of a better hashing algorithm. This process includes sorting on the bits of the key to prioritize the use of them in the XOR hashing sequence, or in simple bit extraction, or even a combination of both. Such an ad hoc hash design is critical to adapting to all real-time situations when there exists a changing (and/or expanding database with an irregular non-uniform distribution. Significant improvement from simulation results is obtained in randomly generated data as well as real data.
Uniform convergence of the empirical spectral distribution function
Mikosch, T; Norvaisa, R
1997-01-01
Let X be a linear process having a finite fourth moment. Assume F is a class of square-integrable functions. We consider the empirical spectral distribution function J(n,X) based on X and indexed by F. If F is totally bounded then J(n,X) satisfies a uniform strong law of large numbers. If, in
Directory of Open Access Journals (Sweden)
Sutrisno Wahyuniarsih
2017-01-01
Full Text Available Uniform corrosion still widely used by a lot of researchers and engineers to analyze the corrosion induced cracking. However, in practice, corrosion process occurred non-uniformly. The part nearest to the exposed surface is more likely to have faster corrosion initiation compared with other regions. This research is mainly focused on investigating the effect of non-uniform rust distribution to cover cracking in reinforced concrete. An experimental test performed using accelerated corrosion test by using 5% NaCl solution and applied a constant electric current to the concrete samples. The rust distribution and measurement were observed by using a digital microscope. Based on the experimental result, it was found that the rust was distributed in a non-uniform pattern. As a result, the cracks also formed non-uniformly along the perimeter of steel bar. At the last part of this paper, a simulation result of concrete cracking induced by non-uniform corrosion is presented. The result compared with a simulation using uniform corrosion assumption to investigate the damage pattern of each model. The simulation result reveals stress evolution due to rust expansion which leads to concrete cracking. Furthermore, a comparison of stresses induced by non-uniform corrosion and uniform corrosion indicates that non-uniform corrosion could lead to earlier damage to the structure which is specified by the formation and propagation of the crack.
Uniform distribution of TiCp in TiCp/Zn-Al composites prepared by XDTM
Institute of Scientific and Technical Information of China (English)
王香; 马旭梁; 李庆芬; 曾松岩
2002-01-01
The prefabricated Al/TiC alloy with high TiC particle content was prepared by XDTM process. The uniform distribution process of TiC particles in the stationary zinc melt was studied and analyzed using self-made experimental equipment, and the model of the uniform distribution process was built. The results show that zinc diffuses into the prepared Al/TiC alloy after it is placed in the zinc melt at temperatures below the melting point of aluminum, which leads to the decrease of the liquidus temperature of Al-Zn alloy in the surface layer of Al/TiC alloy. When the liquidus temperature of Al-Zn alloy is equal to or below the temperature of zinc melt, Al-Zn alloy melts and TiC particles drop with it from the Al/TiC alloy and then transfer into the zinc melt and finally distribute uniformly in it.
Malevergne, Yannick; Pisarenko, Vladilen; Sornette, Didier
2011-03-01
Fat-tail distributions of sizes abound in natural, physical, economic, and social systems. The lognormal and the power laws have historically competed for recognition with sometimes closely related generating processes and hard-to-distinguish tail properties. This state-of-affair is illustrated with the debate between Eeckhout [Amer. Econ. Rev. 94, 1429 (2004)] and Levy [Amer. Econ. Rev. 99, 1672 (2009)] on the validity of Zipf's law for US city sizes. By using a uniformly most powerful unbiased (UMPU) test between the lognormal and the power-laws, we show that conclusive results can be achieved to end this debate. We advocate the UMPU test as a systematic tool to address similar controversies in the literature of many disciplines involving power laws, scaling, "fat" or "heavy" tails. In order to demonstrate that our procedure works for data sets other than the US city size distribution, we also briefly present the results obtained for the power-law tail of the distribution of personal identity (ID) losses, which constitute one of the major emergent risks at the interface between cyberspace and reality.
High density, uniformly distributed W/UO2 for use in Nuclear Thermal Propulsion
Tucker, Dennis S.; Barnes, Marvin W.; Hone, Lance; Cook, Steven
2017-04-01
An inexpensive, quick method has been developed to obtain uniform distributions of UO2 particles in a tungsten matrix utilizing 0.5 wt percent low density polyethylene. Powders were sintered in a Spark Plasma Sintering (SPS) furnace at 1600 °C, 1700 °C, 1750 °C, 1800 °C and 1850 °C using a modified sintering profile. This resulted in a uniform distribution of UO2 particles in a tungsten matrix with high densities, reaching 99.46% of theoretical for the sample sintered at 1850 °C. The powder process is described and the results of this study are given below.
Temperature distribution in a uniformly moving medium
International Nuclear Information System (INIS)
Mitchell, Joseph D; Petrov, Nikola P
2009-01-01
We apply several physical ideas to determine the steady temperature distribution in a medium moving with uniform velocity between two infinite parallel plates. We compute it in the coordinate frame moving with the medium by integration over the 'past' to account for the influence of an infinite set of instantaneous point sources of heat in past moments as seen by an observer moving with the medium. The boundary heat flux is simulated by appropriately distributed point heat sources on the inner side of an adiabatically insulating boundary. We make an extensive use of the Green functions with an emphasis on their physical meaning. The methodology used in this paper is of great pedagogical value as it offers an opportunity for students to see the connection between powerful mathematical techniques and their physical interpretation in an intuitively clear physical problem. We suggest several problems and a challenging project that can be easily incorporated in undergraduate or graduate courses
International Nuclear Information System (INIS)
Scherpelz, R.I.; MacLellan, J.A.
1987-09-01
The Pacific Northwest Laboratory (PNL) is sending a torso phantom with radioactive material uniformly distributed in the lungs to in vivo bioassay laboratories for analysis. Although the radionuclides ultimately chosen for the studies had relatively long half-lives, future accreditation testing will require repeated tests with short half-life test nuclides. Computer modeling was used to simulate the major components of the phantom. Radiation transport calculations were then performed using the computer models to calculate dose rates either 15 cm from the chest or at its surface. For 144 Ce and 60 Co, three configurations were used for the lung comparison tests. Calculations show that, for most detector positions, a single plug containing 40 K located in the back of the heart provides a good approximation to a uniform distribution of 40 K. The approximation would lead, however, to a positive bias for the detector reading if the detector were located at the chest surface near the center. Loading the 40 K in a uniform layer inside the chest wall is not a good approximation of the uniform distribution in the lungs, because most of the radionuclides would be situated close to the detector location and the only shielding would be the thickness of the chest wall. The calculated dose rates for 60 Co and 144 Ce were similar at all calculated reference points. 3 refs., 5 figs., 10 tabs
Zemlyanaya, N. V.; Gulyakin, A. V.
2017-11-01
The uniformity of flow distribution in perforated manifolds is a relevant task. The efficiency of water supply, sewerage and perflation systems is determined by hydraulics of the flow with a variable mass. The extensive study of versatile available information showed that achieving a uniform flow distribution through all of the outlets is almost impossible. The analysis of the studies conducted by other authors and our numerical experiments performed with the help of the software package ANSYS 16.1 were made in this work. The results allowed us to formulate the main causes of non-uniform flow distribution. We decided to suggest a hypothesis to explain the static pressure rise problem at the end of a perforated manifold.
Uniform distribution and quasi-Monte Carlo methods discrepancy, integration and applications
Kritzer, Peter; Pillichshammer, Friedrich; Winterhof, Arne
2014-01-01
The survey articles in this book focus on number theoretic point constructions, uniform distribution theory, and quasi-Monte Carlo methods. As deterministic versions of the Monte Carlo method, quasi-Monte Carlo rules enjoy increasing popularity, with many fruitful applications in mathematical practice, as for example in finance, computer graphics, and biology.
Electron Beam Dose Distribution in the Presence of Non-Uniform Magnetic Field
Directory of Open Access Journals (Sweden)
Mohamad Javad Tahmasebi-Birgani
2014-04-01
Full Text Available Introduction Magnetic fields are capable of altering the trajectory of electron beams andcan be used in radiation therapy.Theaim of this study was to produce regions with dose enhancement and reduction in the medium. Materials and Methods The NdFeB permanent magnets were arranged on the electron applicator in several configurations. Then, after the passage of the electron beams (9 and 15 MeV Varian 2100C/D through the non-uniform magnetic field, the Percentage Depth Dose(PDDs on central axis and dose profiles in three depths for each energy were measured in a 3D water phantom. Results For all magnet arrangements and for two different energies, the surface dose increment and shift in depth of maximum dose (dmax were observed. In addition, the pattern of dose distribution in buildup region was changed. Measurement of dose profile showed dose localization and spreading in some other regions. Conclusion The results of this study confirms that using magnetic field can alter the dose deposition patterns and as a result can produce dose enhancement as well as dose reduction in the medium using high-energy electron beams. These effects provide dose distribution with arbitrary shapes for use in radiation therapy.
Schmitz, Max; Dähler, Fabian; Elvinger, François; Pedretti, Andrea; Steinfeld, Aldo
2017-04-10
We introduce a design methodology for nonimaging, single-reflection mirrors with polygonal inlet apertures that generate a uniform irradiance distribution on a polygonal outlet aperture, enabling a multitude of applications within the domain of concentrated photovoltaics. Notably, we present single-mirror concentrators of square and hexagonal perimeter that achieve very high irradiance uniformity on a square receiver at concentrations ranging from 100 to 1000 suns. These optical designs can be assembled in compound concentrators with maximized active area fraction by leveraging tessellation. More advanced multi-mirror concentrators, where each mirror individually illuminates the whole area of the receiver, allow for improved performance while permitting greater flexibility for the concentrator shape and robustness against partial shading of the inlet aperture.
Modelling non-uniform strain distributions in aerospace composites using fibre Bragg gratings
Rajabzadehdizaji, Aydin; Groves, R.M.; Hendriks, R.C.; Heusdens, R.; Chung, Y.; Jin, W.; Lee, B.; Canning, J.; Nakamura, K.; Yuan, L.
2017-01-01
In this paper the behaviour of fibre Bragg grating (FBG) sensors under non-uniform strain distributions was analysed. Using the fundamental matrix approach, the length of the FBG sensor was discretised, with each segment undergoing different strain values. FBG sensors that are embedded inside
Environmental radionuclide concentrations: statistical model to determine uniformity of distribution
International Nuclear Information System (INIS)
Cawley, C.N.; Fenyves, E.J.; Spitzberg, D.B.; Wiorkowski, J.; Chehroudi, M.T.
1980-01-01
In the evaluation of data from environmental sampling and measurement, a basic question is whether the radionuclide (or pollutant) is distributed uniformly. Since physical measurements have associated errors, it is inappropriate to consider the measurements alone in this determination. Hence, a statistical model has been developed. It consists of a weighted analysis of variance with subsequent t-tests between weighted and independent means. A computer program to perform the calculations is included
High density, uniformly distributed W/UO{sub 2} for use in Nuclear Thermal Propulsion
Energy Technology Data Exchange (ETDEWEB)
Tucker, Dennis S., E-mail: dr.dennis.tucker@nasa.gov [EM32, MSFC, Al 35812 (United States); Barnes, Marvin W. [EM32, MSFC, Al 35812 (United States); Hone, Lance; Cook, Steven [Center for Space Nuclear Research, Idaho Falls, ID 83401 (United States)
2017-04-01
An inexpensive, quick method has been developed to obtain uniform distributions of UO{sub 2} particles in a tungsten matrix utilizing 0.5 wt percent low density polyethylene. Powders were sintered in a Spark Plasma Sintering (SPS) furnace at 1600 °C, 1700 °C, 1750 °C, 1800 °C and 1850 °C using a modified sintering profile. This resulted in a uniform distribution of UO{sub 2} particles in a tungsten matrix with high densities, reaching 99.46% of theoretical for the sample sintered at 1850 °C. The powder process is described and the results of this study are given below.
International Nuclear Information System (INIS)
Rosales, J.; Perez, J.; Garcia, C.; Munnoz, A.; Lira, C. A. B. O.
2015-01-01
TRISO particles are the specific features of HTR-10 and generally HTGR reactors. Their heterogeneity and random arrangement in graphite matrix of these reactors create a significant modeling challenge. In the simulation of spherical fuel elements using MCNPX are usually created repetitive structures using uniform distribution models. The use of these repetitive structures introduces two major approaches: the non-randomness of the TRISO particles inside the pebbles and the intersection of the pebble surface with the TRISO particles. These approaches could affect significantly the multiplicative properties of the core. In order to study the influence of these approaches in the multiplicative properties was estimated the K inf value in one pebble with white boundary conditions using 4 different configurations regarding the distribution of the TRISO particles inside the pebble: uniform hexagonal model, cubic uniform model, cubic uniform without the effect of cutting and a random distribution model. It was studied the impact these models on core scale solving the problem B1, from the Benchmark Problems presented in a Coordinated Research Program of the IAEA. (Author)
Jing, Haiquan; He, Xuhui; Zou, Yunfeng; Wang, Hanfeng
2018-03-01
Stay cables are important load-bearing structural elements of cable-stayed bridges. Suppressing the large vibrations of the stay cables under the external excitations is of worldwide concern for the bridge engineers and researchers. Over the past decade, the use of crosstie has become one of the most practical and effective methods. Extensive research has led to a better understanding of the mechanics of cable networks, and the effects of different parameters, such as length ratio, mass-tension ratio, and segment ratio on the effectiveness of the crosstie have been investigated. In this study, uniformly distributed elastic crossties serve to replace the traditional single, or several cross-ties, aiming to delay "mode localization." A numerical method is developed by replacing the uniformly distributed, discrete elastic cross-tie model with an equivalent, continuously distributed, elastic cross-tie model in order to calculate the modal frequencies and mode shapes of the cable-crosstie system. The effectiveness of the proposed method is verified by comparing the elicited results with those obtained using the previous method. The uniformly distributed elastic cross-ties are shown to significantly delay "mode localization."
The importance of non-uniform dose-distribution in an organ
International Nuclear Information System (INIS)
Richmond, C.R.
1975-01-01
The recent revival of interest in the 'hot particle' problem, especially as regards particulate plutonium and other actinide elements in the lung, stimulated the preparation of this paper. Non-uniformity of dose-distribution has been of concern to standards-setting bodies and other groups such as the National Academy of Sciences and to health protectionists for many years. This paper reviews data from animal experiments that are used by some to implicate particulate plutonium as being especially hazardous to man. Other relevant biological data are also discussed. (author)
Design of a collector shape for uniform flow distribution in microchannels
International Nuclear Information System (INIS)
Siddique, Ayyaz; Agrawal, Amit; Saha, Sandip K; Medhi, Bhaskar J; Singh, Anugrah
2017-01-01
The focus of this study is the design of a collector with the objective of achieving uniform flow in multiple parallel microchannels. This objective is achieved by understanding the limitations of current designs and a novel design is proposed, which is further carefully optimized. The existing collector shape considered is U-type, which is investigated numerically. The creation of a stagnation zone, growth of a boundary layer along the collector wall and low/high velocity zones in the collector are identified as the prime causes of flow maldistribution. A novel design, a dumbbell shape collector, is proposed to overcome the limitations of the earlier designs. The dumbbell shape is evaluated quantitatively and is found to perform better than all existing shapes. This dumbbell shape collector provides a uniform flow distribution with less than 0.4% relative difference from the average flow rate in different channels, which is substantially better than existing collectors with 2.3% relative difference from the average flow rate for Re ch = 32. The uniformity is further confirmed using micro-particle image velocimetry measurements. The dumbbell shape collector is generalized and optimized to cater to heat sinks of different dimensions and to broaden its applicability in both micro and macro dimensions. (paper)
Reactivity effect of non-uniformly distributed fuel in fuel solution systems
International Nuclear Information System (INIS)
Hirano, Yasushi; Yamane, Yoshihiro; Nishina, Kojiro; Mitsuhashi, Ishi.
1991-01-01
A numerical method to determine the optimal fuel distribution for minimum critical mass, or maximum k-effective, is developed using the Maximum Principle in order to evaluate the maximum effect of non-uniformly distributed fuel on reactivity. This algorithm maximizes the Hamiltonian directly by an iterative method under a certain constraint-the maintenance of criticality or total fuel mass. It ultimately reaches the same optimal state of a flattened fuel importance distribution as another algorithm by Dam based on perturbation theory. This method was applied to two kinds of spherical cores with water reflector in the simulating reprocessing facility. In the slightly-enriched uranyl nitrate solution core, the minimum critical mass decreased by less than 1% at the optimal moderation state. In the plutonium nitrate solution core, the k-effective increment amounted up to 4.3% Δk within the range of present study. (author)
Strain distributions in nano-onions with uniform and non-uniform compositions
International Nuclear Information System (INIS)
Duan, H L; Karihaloo, B L; Wang, J; Yi, X
2006-01-01
Nano-onions are ellipsoidal or spherical particles consisting of a core surrounded by concentric shells of nanometre size. Nano-onions produced by self-assembly and colloidal techniques have different structures and compositions, and thus differ in the state of strains. The mismatch of the thermal expansion coefficients and lattice constants between neighbouring shells induces stress/strain fields in the core and shells, which in turn affect their physical/mechanical properties and/or the properties of the composites containing them. In this paper, the strains in embedded and free-standing nano-onions with uniform and non-uniform compositions are studied in detail. It is found that the strains in the nano-onions can be modified by adjusting their compositions and structures. The results are useful for the band structure engineering of semiconductor nano-onions
International Nuclear Information System (INIS)
Diaz, J.E.
1982-01-01
The non-invasive, fully three-dimensional reconstruction of a radionuclide distribution is studied. The problem is considered in ideal form. Several solutions, ranging from the completely analytical to the completely graphical, are presented for both the non-attenuated and uniformly attenuated cases. A function is defined which, if enacted as a response to each detected photon, will yield, upon superposition, a faithful reconstruction of the radionuclide density. Two and three-dimensional forms of this functions are defined for both the non-attenuated and uniformly attenuated case
International Nuclear Information System (INIS)
Shuchi, S.; Shimada, K.; Kamiyama, S.; Yamaguchi, H.
2002-01-01
We clarify numerically the wall friction coefficient, the distributions of velocity and shear rate, and the number of aggregated particles on steady magnetic fluid flow in a straight tube by taking into account the non-uniform distribution of mass concentration (DMC). Also the effect of DMC is clarified under the uniform and non-uniform transverse steady magnetic field. In comparison with the published data, the numerical results show good agreement with the experimental data
Age-dependent effective doses for radionuclides uniformly distributed in air
International Nuclear Information System (INIS)
Hung, Tran Van
2014-01-01
Age-dependent effective doses for external exposure to photons emitted by radionuclides uniformly distributed in air are reported. The calculations were performed for 160 radionuclides, which are important for safety assessment of nuclear facilities. The energies and intensities of photons emitted from radionuclides were taken from the decay data DECDC used for dose calculations. The results are tabulated in the form of effective dose per unit concentration and time (Sv per Bq s m -3 ) for 6 age groups: newborn, 1, 5, 10 and 15 years-old and adult. The effective doses for the adult are also compared to values given in the literature.
Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei
2015-01-01
A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.
Uniform-related infection control practices of dental students
Directory of Open Access Journals (Sweden)
Aljohani Y
2017-04-01
Full Text Available Yazan Aljohani,1 Mohammed Almutadares,1 Khalid Alfaifi,1 Mona El Madhoun,1 Maysoon H Albahiti,2 Nadia Al-Hazmi3 1Internship Program, Faculty of dentistry, King Abdulaziz University, 2Department of Endodontics, King Abdulaziz University, 3Department of Oral Biology, King Abdulaziz University, Faculty of Dentistry, Jeddah, Saudi Arabia Background: Uniform-related infection control practices are sometimes overlooked and underemphasized. In Saudi Arabia, personal protective equipment must meet global standards for infection control, but the country’s Islamic legislature also needs to be taken into account. Aim: To assess uniform-related infection control practices of a group of dental students in a dental school in Saudi Arabia and compare the results with existing literature related to cross-contamination through uniforms in the dental field. Method: A questionnaire was formulated and distributed to dental students at King Abdulaziz University Faculty of Dentistry in Jeddah, Saudi Arabia, which queried the students about their uniform-related infection control practices and their methods and frequency of laundering and sanitizing their uniforms, footwear, and name tags. Results: There is a significant difference between genders with regard to daily uniform habits. The frequency of uniform washing was below the standard and almost 30% of students were not aware of how their uniforms are washed. Added to this, there is no consensus on a unified uniform for male and female students. Conclusion: Information on preventing cross-contamination through wearing uniforms must be supplied, reinforced, and emphasized while taking into consideration the cultural needs of the Saudi society. Keywords: cross-contamination, infection control, dental students, uniforms
Skin carcinogenesis following uniform and non-uniform β irradiation
International Nuclear Information System (INIS)
Charles, M.W.; Williams, J.P.; Coggle, J.E.
1989-01-01
Where workers or the general public may be exposed to ionising radiation, the irradiation is rarely uniform. The risk figures and dose limits recommended by the International Commission on Radiological Protection (ICRP) are based largely on clinical and epidemiological studies of reasonably uniform irradiated organs. The paucity of clinical or experimental data for highly non-uniform exposures has prevented the ICRP from providing adequate recommendations. This weakness has led on a number of occasions to the postulate that highly non-uniform exposures of organs could be 100,000 times more carcinogenic than ICRP risk figures would predict. This so-called ''hot-particle hypothesis'' found little support among reputable radiobiologists, but could not be clearly and definitively refuted on the basis of experiment. An experiment, based on skin tumour induction in mouse skin, is described which was developed to test the hypothesis. The skin of 1200 SAS/4 male mice has been exposed to a range of uniform and non-uniform sources of the β emitter 170 Tm (E max ∼ 1 MeV). Non-uniform exposures were produced using arrays of 32 or 8 2-mm diameter sources distributed over the same 8-cm 2 area as a uniform control source. Average skin doses varied from 2-100 Gy. The results for the non-uniform sources show a 30% reduction in tumour incidence by the 32-point array at the lower mean doses compared with the response from uniform sources. The eight-point array showed an order-of-magnitude reduction in tumour incidence compared to uniform irradiation at low doses. These results, in direct contradiction to the ''hot particle hypothesis'', indicate that non-uniform exposures produce significantly fewer tumours than uniform exposures. (author)
Novel Composite Powders with Uniform TiB2 Nano-Particle Distribution for 3D Printing
Directory of Open Access Journals (Sweden)
Mengxing Chen
2017-03-01
Full Text Available It is reported that the ductility and strength of a metal matrix composite could be concurrently improved if the reinforcing particles were of the size of nanometers and distributed uniformly. In this paper, we revealed that gas atomization solidification could effectively disperse TiB2 nanoparticles in the Al alloy matrix due to its fast cooling rate and the coherent orientation relationship between TiB2 particles and α-Al. Besides, nano-TiB2 led to refined equiaxed grain structures. Furthermore, the composite powders with uniformly embedded nano-TiB2 showed improved laser absorptivity. The novel composite powders are well suited for selective laser melting.
Roles of ethylene glycol solvent and polymers in preparing uniformly distributed MgO nanoparticles
Directory of Open Access Journals (Sweden)
Chunxi Hai
2017-06-01
Full Text Available This study focus on specifying the roles of solvent ethylene glycol (EG and polymers for synthesis of uniformly distributed magnesium oxide (MgO nanoparticles with average crystallite size of around 50 nm through a modified polyol method. Based on different characterization results, it was concluded that, Mg2+ ions was precipitated by the −OH and CO32− ions decomposed from urea in ethylene glycol (EG medium (CO(NH22 → NH3 + HNCO, HNCO + H2O → NH3 + CO2, thus forming well crystallized Mg5(CO34(OH2 (H2O4 precursor which could be converted to MgO by calcination. Surface protectors PEG and PVP have no obvious influences on cyrtsal structure, morphology and size uniformity of as-prepared precursors and target MgO nanoparticles. In comparison with polymers PEG and PVP, solvent EG plays an important role in controlling the morphology and diameter uniformity of MgO nanoparticles.
International Nuclear Information System (INIS)
Qian Libo; Qiu Suizheng; Zhang Dalin; Su Guanghui; Tian Wenxi
2010-01-01
Molten salt reactor is one of the six Generation IV systems capable of breeding and transmutation of actinides and long-lived fission products, which uses the liquid molten salt as the fuel solvent, coolant and heat generation simultaneously. The present work presents a numerical investigation on natural convection with non-uniform heat generation through which the heat generated by the fluid fuel is removed out of the core region when the reactor is under post-accident condition or zero-power condition. The two-group neutron diffusion equation is applied to calculated neutron flux distribution, which leads to non-uniform heat generation. The SIMPLER algorithm is used to calculate natural convective heat transfer rate with isothermal or adiabatic rigid walls. These two models are coupled through the temperature field and heat sources. The peculiarities of natural convection with non-uniform heat generation are investigated in a range of Ra numbers (10 3 ∼ 10 7 ) for the laminar regime of fluid motion. In addition, the numerical results are also compared with those containing uniform heat generation.
Size Distribution Imaging by Non-Uniform Oscillating-Gradient Spin Echo (NOGSE MRI.
Directory of Open Access Journals (Sweden)
Noam Shemesh
Full Text Available Objects making up complex porous systems in Nature usually span a range of sizes. These size distributions play fundamental roles in defining the physicochemical, biophysical and physiological properties of a wide variety of systems - ranging from advanced catalytic materials to Central Nervous System diseases. Accurate and noninvasive measurements of size distributions in opaque, three-dimensional objects, have thus remained long-standing and important challenges. Herein we describe how a recently introduced diffusion-based magnetic resonance methodology, Non-Uniform-Oscillating-Gradient-Spin-Echo (NOGSE, can determine such distributions noninvasively. The method relies on its ability to probe confining lengths with a (length6 parametric sensitivity, in a constant-time, constant-number-of-gradients fashion; combined, these attributes provide sufficient sensitivity for characterizing the underlying distributions in μm-scaled cellular systems. Theoretical derivations and simulations are presented to verify NOGSE's ability to faithfully reconstruct size distributions through suitable modeling of their distribution parameters. Experiments in yeast cell suspensions - where the ground truth can be determined from ancillary microscopy - corroborate these trends experimentally. Finally, by appending to the NOGSE protocol an imaging acquisition, novel MRI maps of cellular size distributions were collected from a mouse brain. The ensuing micro-architectural contrasts successfully delineated distinctive hallmark anatomical sub-structures, in both white matter and gray matter tissues, in a non-invasive manner. Such findings highlight NOGSE's potential for characterizing aberrations in cellular size distributions upon disease, or during normal processes such as development.
Energy Technology Data Exchange (ETDEWEB)
Llacer Martos, S.; Puchal Ane, R.
2011-07-01
To characterize the uniformity of a gamma camera extrinsic used integral uniformity coefficient is calculated with the value of two pixels, the maximum and minimum, single source acquisition of a flat and uniform. This method does not take into account the fact that if a gamma camera having a uniform response, the distribution of these items should be random. In this paper we study how these points are distributed in a succession of large numbers of uniform images.
Directory of Open Access Journals (Sweden)
Dafen Chen
2016-10-01
Full Text Available A battery model that has the capability of analyzing the internal non-uniformity of local state variables, including the state of charge (SOC, temperature and current density, is proposed in this paper. The model is built using a set of distributed parameter equivalent circuits. In order to validate the accuracy of the model, a customized battery with embedded T-type thermocouple sensors inside the battery is tested. The simulated temperature conforms well with the measured temperature at each test point, and the maximum difference is less than 1 °C. Then, the model is applied to analyze the evolution processes of local state variables’ distribution inside the battery during the discharge process. The simulation results demonstrate drastic distribution changes of the local state variables inside the battery during the discharge process. The internal non-uniformity is originally caused by the resistance of positive and negative foils, while also influenced by the change rate of open circuit voltage and the total resistance of the battery. Hence, the factors that affect the distribution of the local state variables are addressed.
Mirbozorgi, S Abdollah; Bahrami, Hadi; Sawan, Mohamad; Gosselin, Benoit
2016-04-01
This paper presents a novel experimental chamber with uniform wireless power distribution in 3D for enabling long-term biomedical experiments with small freely moving animal subjects. The implemented power transmission chamber prototype is based on arrays of parallel resonators and multicoil inductive links, to form a novel and highly efficient wireless power transmission system. The power transmitter unit includes several identical resonators enclosed in a scalable array of overlapping square coils which are connected in parallel to provide uniform power distribution along x and y. Moreover, the proposed chamber uses two arrays of primary resonators, facing each other, and connected in parallel to achieve uniform power distribution along the z axis. Each surface includes 9 overlapped coils connected in parallel and implemented into two layers of FR4 printed circuit board. The chamber features a natural power localization mechanism, which simplifies its implementation and ease its operation by avoiding the need for active detection and control mechanisms. A single power surface based on the proposed approach can provide a power transfer efficiency (PTE) of 69% and a power delivered to the load (PDL) of 120 mW, for a separation distance of 4 cm, whereas the complete chamber prototype provides a uniform PTE of 59% and a PDL of 100 mW in 3D, everywhere inside the chamber with a size of 27×27×16 cm(3).
Controlling of density uniformity of polyacrylate foams
International Nuclear Information System (INIS)
Shan Wenwen; Yuan Baohe; Wang Yanhong; Xu Jiayun; Zhang Lin
2010-01-01
The density non-uniformity existing in most low-density foams will affect performance of the foams. The trimethylolpropane trimethacrylate (TMPTA) foam targets were prepared and controlling methods of the foams, density uniformity were explored together with its forming mechanism. It has been found that the UV-light with high intensity can improve the distribution uniformity of the free radicals induced by UV photons in the solvents, thus improve the density uniformity of the foams. In addition, container wall would influence the concentration distribution of the solution, which affects the density uniformity of the foams. Thus, the UV-light with high intensity was chosen together with polytetrafluoroethylene molds instead of glass molds to prepare the foams with the density non-uniformity less than 10%. β-ray detection technology was used to measure the density uniformity of the TMPTA foams with the density in the range of 10 to 100 mg · cm -3 , and the results show that the lower the foam density is, the worse the density uniformity is. (authors)
International Nuclear Information System (INIS)
Barnett, P.G.
1964-11-01
The practice of using burnout data for uniformly heated round tubes to predict burnout in non-uniformly heated reactor channels having complex cross sections is examined. At least two hypotheses are involved: (i) a relationship exists between uniform and non-uniform heat flux distributions and (ii) a relationship exists between simple and complex channel cross sections. Use of two such hypotheses each accurate to ± 15% and a correlation of uniformly heated round tube data having an R.M.S. error of 5%, could yield errors of ± 40% in any predicted value; this figure of ± 40% is regarded as a realistic upper limit for design purposes. It is shown that no method can exist for relating different channel cross sections to within ± 15% and existing methods for relating different heat flux distributions incur some errors exceeding 20%. Furthermore, any suggested method for relating different heat flux distributions can be adequately checked only when a sufficiently large number of results are available and then the preferable alternative of correlating the data is possible. It is concluded that no reliable method can exist for predicting burnout in rod bundles from uniformly heated round tube data with sufficient accuracy for design purposes. (author)
Directory of Open Access Journals (Sweden)
D. V. Duhopel'nikov
2014-01-01
Full Text Available Cathodic arc evaporators are used for coating with functional films. Prolonged or buttend evaporators may be used for this purposes. In butt-end evaporator the cathode spots move continuously on the cathode work surface and evaporate cathode material. High depth excavation profile forms on the cathode work surface while the thick coating precipitation (tens or hundreds of microns. The cathode excavation profile is shaped like a “cup” with high walls for electrostatic discharge stabilization systems with axial magnetic fields. Cathode spots move on the bottom of the “cup”. It is very likely that high “cup” walls are formed as a result of lasting work time influence on the uniformity of precipitated films.In the present work the influence of excavation profile walls height on the uniformity of precipitated coating was carried out. The high profile walls are formed due to lasting work of DC vacuum arc evaporator. The cathode material used for tests was 3003 aluminum alloy. The extended substrate was placed parallel to the cathode work surface. Thickness distribution along the substrate length with the new cathode was obtained after 6 hours and after 12 hours of continuous operation.The thickness distribution of precipitated coating showed that the cathode excavation has an influence on the angular distribution of the matter escaping the cathode. It can be clearly seen from the normalized dependence coating thickness vs the distance from the substrate center. Also the angular distribution of the matter flow from the cathode depending on the cathode working time was obtained. It was shown that matter flow from the cathode differs from the LambertKnudsen law. The more the cathode excavation the more this difference.So, cathode excavation profile has an influence on the uniformity of precipitated coating and it is necessary to take in account the cathode excavation profile while coating the thick films.
International Nuclear Information System (INIS)
Medin, Paul M.; Foster, Ryan D.; Kogel, Albert J. van der; Sayre, James W.; McBride, William H.; Solberg, Timothy D.
2013-01-01
Background and purpose: This study was performed to test the hypothesis that spinal cord radiosensitivity is significantly modified by uniform versus laterally non-uniform dose distributions. Materials and methods: A uniform dose distribution was delivered to a 4.5–7.0 cm length of cervical spinal cord in 22 mature Yucatan minipigs for comparison with a companion study in which a laterally non-uniform dose was given [1]. Pigs were allocated into four dose groups with mean maximum spinal cord doses of 17.5 ± 0.1 Gy (n = 7), 19.5 ± 0.2 Gy (n = 6), 22.0 ± 0.1 Gy (n = 5), and 24.1 ± 0.2 Gy (n = 4). The study endpoint was motor neurologic deficit determined by a change in gait within one year. Spinal cord sections were stained with a Luxol fast blue/periodic acid Schiff combination. Results: Dose–response curves for uniform versus non-uniform spinal cord irradiation were nearly identical with ED 50 ’s (95% confidence interval) of 20.2 Gy (19.1–25.8) and 20.0 Gy (18.3–21.7), respectively. No neurologic change was observed for either dose distribution when the maximum spinal cord dose was ⩽17.8 Gy while all animals experienced deficits at doses ⩾21.8 Gy. Conclusion: No dose-volume effect was observed in pigs for the dose distributions studied and the endpoint of motor neurologic deficit; however, partial spinal cord irradiation resulted in less debilitating neurologic morbidity and histopathology
Uniform irradiation of irregularly shaped cavities for photodynamic therapy.
Rem, A I; van Gemert, M J; van der Meulen, F W; Gijsbers, G H; Beek, J F
1997-03-01
It is difficult to achieve a uniform light distribution in irregularly shaped cavities. We have conducted a study on the use of hollow 'integrating' moulds for more uniform light delivery of photodynamic therapy in irregularly shaped cavities such as the oral cavity. Simple geometries such as a cubical box, a sphere, a cylinder and a 'bottle-neck' geometry have been investigated experimentally and the results have been compared with computed light distributions obtained using the 'radiosity method'. A high reflection coefficient of the mould and the best uniform direct irradiance possible on the inside of the mould were found to be important determinants for achieving a uniform light distribution.
Kannojiya, Vikas; Sharma, Riya; Gaur, Rahul; Jangra, Anil; Yadav, Pushpender; Prajapati, Pooja
2018-03-01
The overheating of an industrial component sometimes may leads to system failure. The convection heat transfer from a heated surface can be effectively enhanced by employing fins on that surface. This Paper emphasizes on the experimental investigation of temperature distribution along the length of pin shaped fin. The analysis is performed on a 100 mm long fin made up of brass with 19.6 mm diameter having thermal conductivity as 111 W/m.K. Temperature at different section of the fin along its length is evaluated experimentally and theoretically. The influence of convection mode viz natural & forced convection and variable heat input on the temperature distribution is evaluated. The result outcomes are then compared with the widely accepted analytical relations. A comparison of convective heat transfer coefficient for uniform and non-uniform area fin is also presented. The results by experimental and analytical method are found to be in good agreement for free convection phenomenon.
Uniform irradiation system using beam scanning method for cyclotron
International Nuclear Information System (INIS)
Agematsu, Takashi; Okumura, Susumu; Arakawa, Kazuo
1994-03-01
JAERI AVF-cyclotron is equipped with an ion beam scanner for large area irradiation. The two-dimensional fluence distribution of ion beam obtained using cellulose triacetate film dosimeter was not uniform. This is resulted from the distortion of excitation current for electromagnet of the scanner. So, the beam scanning condition, i.e., the relation between the ion species, the beam profile and the scanning width, was extremely limited to make a good uniformity. We have developed a beam scanning simulator to get fluence distributions by calculation and then compared the simulated distributions with the measured ones. It was revealed that the both of them are in good agreement and the beam scanning condition to get good uniformity was led by using this simulator. On the basis of these results, the power supply of scanner was improved. A good uniformity of beam distribution was available. (author)
International Nuclear Information System (INIS)
Ishitani, Kazuki; Yamane, Yoshihiro
1999-01-01
In nuclear fuel reprocessing plants, monitoring the spatial profile of neutron flux to infer subcriticality and distribution of fuel concentration using detectors such as PSPC, is very beneficial in sight of criticality safety. In this paper a method of subcriticality and fuel concentration estimation which is supposed to use under non-uniformed system is proposed. Its basic concept is the pattern matching between measured neutron flux distribution and beforehand calculated one. In any kind of subcriticality estimation, we can regard that measured neutron counts put any kind of black box, and then this black box outputs subcriticality. We proposed the use of artificial neural network or 'pattern matching' as black box which have no theoretical clear base. These method are wholly based on the calculated value as recently advancement of computer code accuracy for criticality safety. The most difference between indirect bias estimation method and our method is that our new approach target are the unknown non-uniform system. (J.P.N.)
Ultrasonic transducer design for uniform insonation
International Nuclear Information System (INIS)
Harrison, G.H.; Balcer-Kubiczek, E.K.; McCulloch, D.
1984-01-01
Techniques used in transducer development for acoustical imaging have been evaluated for the purpose of producing broad, uniform ultrasonic fields from planar radiators. Such fields should be useful in hyperthermia, physical therapy, and ultrasonic bioeffects studies. Fourier inversion of the circ function yielded a source velocity distribution proportional to (P/r) exp ((-ik/2Z) (2Z/sup 2/+r/sup 2/)) J/sub 1/(krP/Z), where r is the radial source coordinate, k is the wave number, and P is the desired radius of uniform insonation at a depth Z in water. This source distribution can be truncated without significantly degrading the solution. A simpler solution consists of exponentially shading the edge of an otherwise uniformly excited disk transducer. This approach was successfully approximated experimentally
Probability distribution of distance in a uniform ellipsoid: Theory and applications to physics
International Nuclear Information System (INIS)
Parry, Michelle; Fischbach, Ephraim
2000-01-01
A number of authors have previously found the probability P n (r) that two points uniformly distributed in an n-dimensional sphere are separated by a distance r. This result greatly facilitates the calculation of self-energies of spherically symmetric matter distributions interacting by means of an arbitrary radially symmetric two-body potential. We present here the analogous results for P 2 (r;ε) and P 3 (r;ε) which respectively describe an ellipse and an ellipsoid whose major and minor axes are 2a and 2b. It is shown that for ε=(1-b 2 /a 2 ) 1/2 ≤1, P 2 (r;ε) and P 3 (r;ε) can be obtained as an expansion in powers of ε, and our results are valid through order ε 4 . As an application of these results we calculate the Coulomb energy of an ellipsoidal nucleus, and compare our result to an earlier result quoted in the literature. (c) 2000 American Institute of Physics
International Nuclear Information System (INIS)
Coleman, P.; Rauch, J.; Rix, W.; Thompson, J.; Wilson, R.
1997-01-01
Hammer (1996) and Velikovich (1996) have discussed ways to mitigate the growth of the magneto-Rayleigh-Taylor (MRT) instability in z-pinch (PRS) implosions. They predict that initial mass distributions more complex than a simple annular shell will reduce instability development. Sanford (1996) reported experimental data showing a benefit for a uniform mass distribution compared to a shell; those tests used ''conventional'' load radii of 2.25 and 1.25 cm respectively, and implosion times under 100 ns. However, the instability problem is expected to grow exponentially as the implosion time, or alternatively the initial radius, increases. Thus we made a comparison of a uniform fill load with a shell but at larger radii, 3.6 and 2.5 cm respectively, and at implosion times well above 100 ns. We see nearly a factor of 10X improvement in peak K-shell power and 2X increase in K-shell yield for the uniform mass load. Hence it appears that suitable tailoring of the imploding mass distribution can significantly limit the instability growth
School Uniform Policies in Public Schools
Brunsma, David L.
2006-01-01
The movement for school uniforms in public schools continues to grow despite the author's research indicating little if any impact on student behavior, achievement, and self-esteem. The author examines the distribution of uniform policies by region and demographics, the impact of these policies on perceptions of school climate and safety, and…
UMAPRM: Uniformly sampling the medial axis
Yeh, Hsin-Yi Cindy
2014-05-01
© 2014 IEEE. Maintaining clearance, or distance from obstacles, is a vital component of successful motion planning algorithms. Maintaining high clearance often creates safer paths for robots. Contemporary sampling-based planning algorithms That utilize The medial axis, or The set of all points equidistant To Two or more obstacles, produce higher clearance paths. However, They are biased heavily Toward certain portions of The medial axis, sometimes ignoring parts critical To planning, e.g., specific Types of narrow passages. We introduce Uniform Medial Axis Probabilistic RoadMap (UMAPRM), a novel planning variant That generates samples uniformly on The medial axis of The free portion of Cspace. We Theoretically analyze The distribution generated by UMAPRM and show its uniformity. Our results show That UMAPRM\\'s distribution of samples along The medial axis is not only uniform but also preferable To other medial axis samplers in certain planning problems. We demonstrate That UMAPRM has negligible computational overhead over other sampling Techniques and can solve problems The others could not, e.g., a bug Trap. Finally, we demonstrate UMAPRM successfully generates higher clearance paths in The examples.
Directory of Open Access Journals (Sweden)
Vladimir Višacki
2017-01-01
Full Text Available Timely and high-quality application of pesticides contributes to environmental protection, economical production and production of healthy food. The efficacy of pesticide application depends not only on the quality of pesticides but also the quality of the application. One of the factor that most influences the quality of applications, from the standpoint of mechanization, are nozzles. They working liquid applied on the surface the plant resulting in the same volume of pesticide is applied to the entire surface of the plants. To achieve this goal, nozzles must be performed uniform application of working liquid per unit area, or tractor sprayer working width. The variable factor in the application of pesticides may be nozzle and operating pressure. With increasing working pressure obtained smaller droplets. The paper presents test of three different nozzles. Each nozzle is characterized by a flat jet with an angle of 110° and a flow rate of 1.6 l∙min−1 at a pressure of 3 bar. Differ from each other are by the way of disintegration of the jet. Exactly this characteristic causes that with pressure change coming to changes in the uniformity of nozzles transverse distribution. So the best distribution has nozzle with a flat jet. The coefficient of variation is between roughly from 4 to 6 % at the pressure application of 2 to 4 bar. Obtained mathematical model that describes changes in the coefficient of variation depending on pressure applications can be a good basis for easy harmonization parameters in the pesticide application.
Bachegowda, Lohith S; Cheng, Yan H; Long, Thomas; Shaz, Beth H
2017-01-01
-Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. -To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. -Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. -A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. -Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.
Probabilistic uniformities of uniform spaces
Energy Technology Data Exchange (ETDEWEB)
Rodriguez Lopez, J.; Romaguera, S.; Sanchis, M.
2017-07-01
The theory of metric spaces in the fuzzy context has shown to be an interesting area of study not only from a theoretical point of view but also for its applications. Nevertheless, it is usual to consider these spaces as classical topological or uniform spaces and there are not too many results about constructing fuzzy topological structures starting from a fuzzy metric. Maybe, H/{sup o}hle was the first to show how to construct a probabilistic uniformity and a Lowen uniformity from a probabilistic pseudometric /cite{Hohle78,Hohle82a}. His method can be directly translated to the context of fuzzy metrics and allows to characterize the categories of probabilistic uniform spaces or Lowen uniform spaces by means of certain families of fuzzy pseudometrics /cite{RL}. On the other hand, other different fuzzy uniformities can be constructed in a fuzzy metric space: a Hutton $[0,1]$-quasi-uniformity /cite{GGPV06}; a fuzzifiying uniformity /cite{YueShi10}, etc. The paper /cite{GGRLRo} gives a study of several methods of endowing a fuzzy pseudometric space with a probabilistic uniformity and a Hutton $[0,1]$-quasi-uniformity. In 2010, J. Guti/'errez Garc/'{/i}a, S. Romaguera and M. Sanchis /cite{GGRoSanchis10} proved that the category of uniform spaces is isomorphic to a category formed by sets endowed with a fuzzy uniform structure, i. e. a family of fuzzy pseudometrics satisfying certain conditions. We will show here that, by means of this isomorphism, we can obtain several methods to endow a uniform space with a probabilistic uniformity. Furthermore, these constructions allow to obtain a factorization of some functors introduced in /cite{GGRoSanchis10}. (Author)
Directory of Open Access Journals (Sweden)
Sara Bardestani
2017-09-01
Full Text Available Triangular channels have different applications in many water and wastewater engineering problems. For this purpose investigating hydraulic characteristics of flow in these sections has great importance. Researchers have presented different prediction methods for the velocity contours in prismatic sections. Most proposed methods are not able to consider the effect of walls roughness, the roughness distribution and secondary flows. However, due to complexity and nonlinearity of velocity contours in open channel flow, there is no simple relationship that can be fully able to exactly draw the velocity contours. In this paper an efficient approach for modeling velocity contours in triangular open channels with non-uniform roughness distributions by Adaptive Neuro-Fuzzy Inference System (ANFIS has been suggested. For training and testing model, the experimental data including 1703 data in triangular channels with geometric symmetry and non-uniform roughness distributions have been used. Comparing experimental results with predicted values by model indicates that ANFIS model is capable to be used in simulation of local velocity and determining velocity contours and the independent evaluation showed that the calculated values of discharge and depth-averaged velocity from model information are precisely in conformity with experimental values.
A method for generating skewed random numbers using two overlapping uniform distributions
International Nuclear Information System (INIS)
Ermak, D.L.; Nasstrom, J.S.
1995-02-01
The objective of this work was to implement and evaluate a method for generating skewed random numbers using a combination of uniform random numbers. The method provides a simple and accurate way of generating skewed random numbers from the specified first three moments without an a priori specification of the probability density function. We describe the procedure for generating skewed random numbers from unifon-n random numbers, and show that it accurately produces random numbers with the desired first three moments over a range of skewness values. We also show that in the limit of zero skewness, the distribution of random numbers is an accurate approximation to the Gaussian probability density function. Future work win use this method to provide skewed random numbers for a Langevin equation model for diffusion in skewed turbulence
International Nuclear Information System (INIS)
Bai, Xue; Zhang, Xiaoyuan; Hua, Zulin; Ma, Wenqiang; Dai, Zhangyan; Huang, Xin; Gu, Haixin
2014-01-01
Highlights: • Uniform distributed TiO 2 nanoparticles on graphene by a modified method. • Reduced recombination rate of photogenerated electron–hole pairs. • Effective charge transfer from TiO 2 to graphene. • Better photocatalytic activity upon UV and visible irradiation. • A mechanism of bisphenol A degradation process is proposed. - Abstract: Graphene (GR)/TiO 2 nanocomposites are successfully synthesized using a simple and efficient hydrothermal method. Even-sized anatase TiO 2 nanoparticles are uniformly distributed on GR. The GR/TiO 2 nanocomposites exhibit an extended light absorption range and decreased electron–hole recombination rates. The photocatalytic activity of the as-prepared GR/TiO 2 nanocomposites for bisphenol A (BPA) degradation is investigated under UV (λ = 365 nm) and visible (λ ⩾ 400 nm) light irradiation. The results show that GR/TiO 2 nanocomposites have significantly higher photocatalytic activity than P25 (pure TiO 2 ). The large increase in photocatalytic activity is mostly attributed to effective charge transfer from TiO 2 nanoparticles to GR, which suppresses charge recombination during the photocatalytic process. After five successive cycles, the photodegradation activity of the GR/TiO 2 nanocomposites shows no significant decrease, which indicates that the nanocomposites are stable under UV and visible light. X-ray photoelectron spectroscopy (XPS) is used to investigate the chemical bonds of GR/TiO 2 nanocomposites before and after degradation to determine the degradation intermediate products of BPA under irradiation. A proposed degradation reaction pathway of BPA is also established. This study provides new insights into the fabrication and practical application of high-performance photocatalysts in wastewater treatment
DEFF Research Database (Denmark)
Hviid, Christian Anker; Lessing, Julian
2016-01-01
suspended ceiling to uniformly distribute the supply air to the occupied zone. This, in effect, increases the thermal mass of the room because the upper slab of the room no longer is isolated from the occupied zone. In this study, the cooling potential of a diffuse ceiling ventilation system is i...
Ideal flood field images for SPECT uniformity correction
International Nuclear Information System (INIS)
Oppenheim, B.E.; Appledorn, C.R.
1984-01-01
Since as little as 2.5% camera non-uniformity can cause disturbing artifacts in SPECT imaging, the ideal flood field images for uniformity correction would be made with the collimator in place using a perfectly uniform sheet source. While such a source is not realizable the equivalent images can be generated by mapping the activity distribution of a Co-57 sheet source and correcting subsequent images of the source with this mapping. Mapping is accomplished by analyzing equal-time images of the source made in multiple precisely determined positions. The ratio of counts detected in the same region of two images is a measure of the ratio of the activities of the two portions of the source imaged in that region. The activity distribution in the sheet source is determined from a set of such ratios. The more source positions imaged in a given time, the more accurate the source mapping, according to results of a computer simulation. A 1.9 mCi Co-57 sheet source was shifted by 12 mm increments along the horizontal and vertical axis of the camera face to 9 positions on each axis. The source was imaged for 20 min in each position and 214 million total counts were accumulated. The activity distribution of the source, relative to the center pixel, was determined for a 31 x 31 array. The integral uniformity was found to be 2.8%. The RMS error for such a mapping was determined by computer simulation to be 0.46%. The activity distribution was used to correct a high count flood field image for non-uniformities attributable to the Co-57 source. Such a corrected image represents camera plus collimator response to an almost perfectly uniform sheet source
Directory of Open Access Journals (Sweden)
Shih-Hao Chan
2013-01-01
Full Text Available Uniformly distributed graphene domains were synthesized on standing copper foil by a low-pressure chemical vapor deposition system. This method improved the distribution of the graphene domains at different positions on the same piece of copper foil along the forward direction of the gas flow. Scanning electron microscopy (SEM showed the average size of the graphene domains to be about ~20 m. This results show that the sheet resistance of monolayer graphene on a polyethylene terephthalate (PET substrate is about ~359 /□ whereas that of the four-layer graphene films is about ~178 /□, with a transmittance value of 88.86% at the 550 nm wavelength. Furthermore, the sheet resistance can be reduced with the addition of HNO3 resulting in a value of 84 /□. These values meet the absolute standard for touch sensor applications, so we believe that this method can be a candidate for some transparent conductive electrode applications.
Murtomaeki, Jaako; Kirby, Glen; Rossi, Lucio; Ruuskanen, Janne; Stenvall, Antti; Murtomaeki, Jaako
2017-01-01
Future high-energy accelerators will need very high magnetic fields in the range of 20 T. The EuCARD-2 WP10 Future Magnets collaboration is aiming at testing HTS-based Roebel cables in an accelerator magnet. The demonstrator should produce around 17 T, when inserted into the 100 mm aperture of Feather-M2 13 T outsert magnet. HTS Roebel cables are assembled from meander shaped REBCO coated conductor tapes. In comparison with fair level of uniformity of current distribution in cables made out of round Nb-Ti or Nb$_{3}$Sn strands, current distribution within the coils wound from Roebel cables is highly non-homogeneous. It results in nonuniform electromagnetic force distribution over the cable that could damage the very thin REBCO superconducting layer. This paper focuses on the numerical models to describe the effect of the non-homogenous current distribution on stress distribution in the demonstrator magnet designed for the EuCARD-2 project. Preliminary results indicate that the impregnation bonding betweenthe...
Energy Technology Data Exchange (ETDEWEB)
Chen, Z.D.; Li, Y.; Mahoney, J. [CSIRO Building, Construction and Engineering, Advanced Thermo-Fluids Technologies Lab., Highett, VIC (Australia)
2001-05-01
A simple multi-layer stratification model is suggested for displacement ventilation in a single-zone building driven by a heat source distributed uniformly over a vertical wall. Theoretical expressions are obtained for the stratification interface height and ventilation flow rate and compared with those obtained by an existing model available in the literature. Experiments were also carried out using a recently developed fine-bubble modelling technique. It was shown that the experimental results obtained using the fine-bubble technique are in good agreement with the theoretical predictions. (Author)
Oliveira, C
2001-01-01
A systematic study of isodose distributions and dose uniformity in sample carriers of the Portuguese Gamma Irradiation Facility was carried out using the MCNP code. The absorbed dose rate, gamma flux per energy interval and average gamma energy were calculated. For comparison purposes, boxes filled with air and 'dummy' boxes loaded with layers of folded and crumpled newspapers to achieve a given value of density were used. The magnitude of various contributions to the total photon spectra, including source-dependent factors, irradiator structures, sample material and other origins were also calculated.
Beam uniformity of flat top lasers
Chang, Chao; Cramer, Larry; Danielson, Don; Norby, James
2015-03-01
Many beams that output from standard commercial lasers are multi-mode, with each mode having a different shape and width. They show an overall non-homogeneous energy distribution across the spot size. There may be satellite structures, halos and other deviations from beam uniformity. However, many scientific, industrial and medical applications require flat top spatial energy distribution, high uniformity in the plateau region, and complete absence of hot spots. Reliable standard methods for the evaluation of beam quality are of great importance. Standard methods are required for correct characterization of the laser for its intended application and for tight quality control in laser manufacturing. The International Organization for Standardization (ISO) has published standard procedures and definitions for this purpose. These procedures have not been widely adopted by commercial laser manufacturers. This is due to the fact that they are unreliable because an unrepresentative single-pixel value can seriously distort the result. We hereby propose a metric of beam uniformity, a way of beam profile visualization, procedures to automatically detect hot spots and beam structures, and application examples in our high energy laser production.
Mishra, Pawan; Janjua, Bilal; Ng, Tien Khee; Shen, Chao; Salhi, Abdelmajid; Alyamani, Ahmed; El-Desouki, Munir; Ooi, Boon S.
2015-01-01
We investigated the design and growth of compositionally-graded InGaN multiple quantum wells (MQW) based light-emitting diode (LED) without an electron-blocking layer (EBL). Numerical investigation showed uniform carrier distribution in the active region, and higher radiative recombination rate for the optimized graded-MQW design, i.e. In0→xGa1→(1-x)N / InxGa(1-x)N / Inx→0Ga(1-x)→1N, as compared to the conventional stepped-MQW-LED. The composition-grading schemes, such as linear, parabolic, and Fermi-function profiles were numerically investigated for comparison. The stepped- and graded-MQW-LED were then grown using plasma assisted molecular beam epitaxy (PAMBE) through surface-stoichiometry optimization based on reflection high-energy electron-diffraction (RHEED) in-situ observations. Stepped- and graded-MQW-LED showed efficiency roll over at 160 A/cm2 and 275 A/cm2, respectively. The extended threshold current density roll-over (droop) in graded-MQW-LED is due to the improvement in carrier uniformity and radiative recombination rate, consistent with the numerical simulation.
Mishra, Pawan
2015-05-06
We investigated the design and growth of compositionally-graded InGaN multiple quantum wells (MQW) based light-emitting diode (LED) without an electron-blocking layer (EBL). Numerical investigation showed uniform carrier distribution in the active region, and higher radiative recombination rate for the optimized graded-MQW design, i.e. In0→xGa1→(1-x)N / InxGa(1-x)N / Inx→0Ga(1-x)→1N, as compared to the conventional stepped-MQW-LED. The composition-grading schemes, such as linear, parabolic, and Fermi-function profiles were numerically investigated for comparison. The stepped- and graded-MQW-LED were then grown using plasma assisted molecular beam epitaxy (PAMBE) through surface-stoichiometry optimization based on reflection high-energy electron-diffraction (RHEED) in-situ observations. Stepped- and graded-MQW-LED showed efficiency roll over at 160 A/cm2 and 275 A/cm2, respectively. The extended threshold current density roll-over (droop) in graded-MQW-LED is due to the improvement in carrier uniformity and radiative recombination rate, consistent with the numerical simulation.
International Nuclear Information System (INIS)
Henry, L.J.; Rosenthal, M.S.
1992-01-01
We report results of scatter simulations for both point and distributed sources of 99m Tc in symmetrical non-uniform attenuating media. The simulations utilized Monte Carlo techniques and were tested against experimental phantoms. Both point and ring sources were used inside a 10.5 cm radius acrylic phantom. Attenuating media consisted of combinations of water, ground beef (to simulate muscle mass), air and bone meal (to simulate bone mass). We estimated/measured energy spectra, detector efficiencies and peak height ratios for all cases. In all cases, the simulated spectra agree with the experimentally measured spectra within 2 SD. Detector efficiencies and peak height ratios also are in agreement. The Monte Carlo code is able to properly model the non-uniform attenuating media used in this project. With verification of the simulations, it is possible to perform initial evaluation studies of scatter correction algorithms by evaluating the mechanisms of action of the correction algorithm on the simulated spectra where the magnitude and sources of scatter are known. (author)
Uniform random number generators
Farr, W. R.
1971-01-01
Methods are presented for the generation of random numbers with uniform and normal distributions. Subprogram listings of Fortran generators for the Univac 1108, SDS 930, and CDC 3200 digital computers are also included. The generators are of the mixed multiplicative type, and the mathematical method employed is that of Marsaglia and Bray.
Evaluation model development for sprinkler irrigation uniformity ...
African Journals Online (AJOL)
A new evaluation method with accompanying software was developed to precisely calculate uniformity from catch-can test data, assuming sprinkler distribution data to be a continuous variable. Two interpolation steps are required to compute unknown water application depths at grid distribution points from radial ...
Energy Technology Data Exchange (ETDEWEB)
Ferrouk, M. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria)], E-mail: m_ferrouk@yahoo.fr; Aissani, S. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria); D' Auria, F.; DelNevo, A.; Salah, A. Bousbia [Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Universita di Pisa (Italy)
2008-10-15
The present article covers the evaluation of the performance of twelve critical heat flux methods/correlations published in the open literature. The study concerns the simulation of an axially non-uniform heat flux distribution with the RELAP5 computer code in a single boiling water reactor channel benchmark problem. The nodalization scheme employed for the considered particular geometry, as modelled in RELAP5 code, is described. For this purpose a review of critical heat flux models/correlations applicable to non-uniform axial heat profile is provided. Simulation results using the RELAP5 code and those obtained from our computer program, based on three type predictions methods such as local conditions, F-factor and boiling length average approaches were compared.
Synthetic approaches to uniform polymers.
Ali, Monzur; Brocchini, Steve
2006-12-30
Uniform polymers are characterised by a narrow molecular weight distribution (MWD). Uniformity is also defined by chemical structure in respect of (1) monomer orientation, sequence and stereo-regularity, (2) polymer shape and morphology and (3) chemical functionality. The function of natural polymers such as polypeptides and polynucleotides is related to their conformational structure (e.g. folded tertiary structure). This is only possible because of their high degree of uniformity. While completely uniform synthetic polymers are rare, polymers with broad structure and MWD are widely used in medicine and the biomedical sciences. They are integral components in final dosage forms, drug delivery systems (DDS) and in implantable devices. Increasingly uniform polymers are being used to develop more complex medicines (e.g. delivery of biopharmaceuticals, enhanced formulations or DDS's for existing actives). In addition to the function imparted by any new polymer it will be required to meet stringent specifications in terms of cost containment, scalability, biocompatibility and performance. Synthetic polymers with therapeutic activity are also being developed to exploit their polyvalent properties, which is not possible with low molecular weight molecules. There is need to utilise uniform polymers for applications where the polymer may interact with the systemic circulation, tissues or cellular environment. There are also potential applications (e.g. stimuli responsive coatings) where uniform polymers may be used for their more defined property profile. While it is not yet practical to prepare synthetic polymers to the same high degree of uniformity as proteins, nature also effectively utilises many polymers with lower degrees of uniformity (e.g. polysaccharides, poly(amino acids), polyhydroxyalkanoates). In recent years it has become possible to prepare with practical experimental protocols sufficient quantities of polymers that display many aspects of uniformity. This
Lahanas, M; Baltas, D; Giannouli, S; Milickovic, N; Zamboglou, N
2000-05-01
We have studied the accuracy of statistical parameters of dose distributions in brachytherapy using actual clinical implants. These include the mean, minimum and maximum dose values and the variance of the dose distribution inside the PTV (planning target volume), and on the surface of the PTV. These properties have been studied as a function of the number of uniformly distributed sampling points. These parameters, or the variants of these parameters, are used directly or indirectly in optimization procedures or for a description of the dose distribution. The accurate determination of these parameters depends on the sampling point distribution from which they have been obtained. Some optimization methods ignore catheters and critical structures surrounded by the PTV or alternatively consider as surface dose points only those on the contour lines of the PTV. D(min) and D(max) are extreme dose values which are either on the PTV surface or within the PTV. They must be avoided for specification and optimization purposes in brachytherapy. Using D(mean) and the variance of D which we have shown to be stable parameters, achieves a more reliable description of the dose distribution on the PTV surface and within the PTV volume than does D(min) and D(max). Generation of dose points on the real surface of the PTV is obligatory and the consideration of catheter volumes results in a realistic description of anatomical dose distributions.
Downsampling Non-Uniformly Sampled Data
Directory of Open Access Journals (Sweden)
Fredrik Gustafsson
2007-10-01
Full Text Available Decimating a uniformly sampled signal a factor D involves low-pass antialias filtering with normalized cutoff frequency 1/D followed by picking out every Dth sample. Alternatively, decimation can be done in the frequency domain using the fast Fourier transform (FFT algorithm, after zero-padding the signal and truncating the FFT. We outline three approaches to decimate non-uniformly sampled signals, which are all based on interpolation. The interpolation is done in different domains, and the inter-sample behavior does not need to be known. The first one interpolates the signal to a uniformly sampling, after which standard decimation can be applied. The second one interpolates a continuous-time convolution integral, that implements the antialias filter, after which every Dth sample can be picked out. The third frequency domain approach computes an approximate Fourier transform, after which truncation and IFFT give the desired result. Simulations indicate that the second approach is particularly useful. A thorough analysis is therefore performed for this case, using the assumption that the non-uniformly distributed sampling instants are generated by a stochastic process.
Analytical examination of a spiral beam scanning method for uniform irradiation
Energy Technology Data Exchange (ETDEWEB)
Fukuda, Mitsuhiro; Okumura, Susumu; Arakawa, Kazuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment
1997-03-01
A new circular beam scanning method for uniform irradiation of high-energy, intense ion beams over a large area has been developed. A sweeping speed and a trajectory density in a radial direction are kept constant to obtain uniform fluence distribution. A radial position of a beam spot on a target and an angular frequency of the circular motion are expressed by an irrational function of time. The beam is swept continuously, and a beam trajectory becomes spiral. More than 90 % uniformity of the fluence distribution can been achieved over a large area. (author)
Uniform irradiation of irregularly shaped cavities for photodynamic therapy
Rem, A. I.; van Gemert, M. J.; van der Meulen, F. W.; Gijsbers, G. H.; Beek, J. F.
1997-01-01
It is difficult to achieve a uniform light distribution in irregularly shaped cavities. We have conducted a study on the use of hollow 'integrating' moulds for more uniform light delivery of photodynamic therapy in irregularly shaped cavities such as the oral cavity. Simple geometries such as a
International Nuclear Information System (INIS)
Chen, Deshen; Qian, Hongliang; Wang, Huajie; Zhang, Gang; Fan, Feng; Shen, Shizhao
2017-01-01
Highlights: • Solar non-uniform temperature field test of a telescope’s reflector is conducted initially. • Time-varying distribution regularities are analyzed contrastively. • Simulation methods are proposed involving environmental factors and self-shadowing. • Refined discrimination method for the shadow distribution is put forward. • Validity of simulation methods is evaluated with the experimental data. - Abstract: To improve the ability of deep-space exploration, many astronomers around the world are actively engaged in the construction of large-aperture and high-precision radio telescopes. The temperature effect is one of three main factors affecting the reflector accuracy of radio telescopes. To study the daily non-uniform temperature field of the main reflector, experimental studies are first carried out with a 3-m-aperture radio telescope model. According to the test results for 16 working conditions, the distribution rule and time-varying regularity of the daily temperature field are summarized initially. Next, theoretical methods for the temperature field of the main reflector are studied considering multiple environmental parameters and self-shadows. Finally, the validity of the theoretical methods is evaluated with test results. The experimental study demonstrates that the non-uniform temperature distribution of the main reflector truly exists and should not be overlooked, and that the theoretical methods for the reflector temperature field proposed in this paper are effective. The research methods and conclusions can provide valuable references for thermal design, monitoring and control of similar high-precision radio telescopes.
Production of titanium alloys with uniform distribution of heat resisting metals
International Nuclear Information System (INIS)
Reznichenko, V.A.; Goncharenko, T.V.; Khalimov, F.B.; Vojtechova, E.A.
1976-01-01
Consideration is given to the process of the formation of a titanium sponge alloyed with niobium or tantalum, in the joint metallic reduction of titanium, niobium and tantanum chlorides. A percentage composition of the phases observed and the structure of the alloyed sponge have been studied. It is shown that after one remelting operation of the alloyed sponge the alloys of titanium with niobium and tantalum have a uniform component distribution. At the stage of chloride reduction there appear solid solutions based on titanium and an alloying component. The stage of vacuum separation of the reaction mass is associated with a mutual dissolution of the primary phases and the formation of the solid solutions of the alloyed titanium sponge, which, by their composition, are close to the desired alloy composition. The principal features of the formation of a titanium sponge alloyed with niobium and tantalum are in a perfect agreemet with those typical of Ti-Mo and Ti-W sponges, therefore it can be assumed that these features will be also common to the other cases of the metallic reduction of titanium and refractory metals chlorides
Production of titanium alloys with uniform distribution of heat resisting metals
Energy Technology Data Exchange (ETDEWEB)
Reznichenko, V A; Goncharenko, T V; Khalimov, F B; Voitechova, E A
1976-01-01
Consideration is given to the process of the formation of a titanium sponge alloyed with niobium or tantalum, in the joint metallic reduction of titanium, niobium and tantanum chlorides. A percentage composition of the phases observed and the structure of the alloyed sponge have been studied. It is shown that after one remelting operation of the alloyed sponge the alloys of titanium with niobium and tantalum have a uniform component distribution. At the stage of chloride reduction there appear solid solutions based on titanium and an alloying component. The stage of vacuum separation of the reaction mass is associated with a mutual dissolution of the primary phases and the formation of the solid solutions of the alloyed titanium sponge, which, by their composition, are close to the desired alloy composition. The principal features of the formation of a titanium sponge alloyed with niobium and tantalum are in a perfect agreemet with those typical of Ti-Mo and Ti-W sponges, therefore it can be assumed that these features will be also common to the other cases of the metallic reduction of titanium and refractory metals chlorides.
Experimental study on the CHF in uniformly and non-uniformly heated vertical annuli
Energy Technology Data Exchange (ETDEWEB)
Chun, Se Young; Moon, Sang Ki; Chung, Heung June; Park, Jong Kuk; Kim, Bok Deuk; Youn, Young Jung; Chung, Moon Ki
2001-09-01
Up to now, KAERI has performed critical heat flux experiments in water under zero-flow and low-flow conditions using a RCS CHF loop facility with uniformly and non-uniformly heated vertical annulus. Since the existing CHF experiments were mainly performed under low-pressure conditions, we performed the CHF experiment to investigate the pressure effect on the CHF under zero-flow and low-flow conditions for a wide range of system pressures. Also, two vertical annuli with the same geometry have been used to investigate the axial heat flux distributions on the CHF. This report summarizes the experimental results and provides the CHF data that can be used for the development for CHF correlation and a thermal hydraulic analysis code. The CHF data have been collected for system pressures ranging from 0.57 to 15.15 MPa, mass flux 0 and from 200 to 650 kg/m2s, inlet subcooling from 75 to 360 kJ/kg and exit quality from 0.07 to 0.57. At low-flow conditions, the total number of data are 242 and 290 with uniformly heated- and non-uniformly heated test sections, respectively. 41 and 94 CHF data are generated with uniformly heated- and non-uniformly heated test sections, respectively, in zero-flow CHF experiments that are performed by blocking test section bottoms. The CHF experiment result shows that the effects of system pressure, mass flux and inlet subcooling are consistent with conventional understandings and similar to those for round tubes. The behavior of the CHF is relatively complex at low pressures. Also, the effects of axial heat flux profile are large at low-pressure conditions.
Experimental study on the CHF in uniformly and non-uniformly heated vertical annuli
International Nuclear Information System (INIS)
Chun, Se Young; Moon, Sang Ki; Chung, Heung June; Park, Jong Kuk; Kim, Bok Deuk; Youn, Young Jung; Chung, Moon Ki
2001-09-01
Up to now, KAERI has performed critical heat flux experiments in water under zero-flow and low-flow conditions using a RCS CHF loop facility with uniformly and non-uniformly heated vertical annulus. Since the existing CHF experiments were mainly performed under low-pressure conditions, we performed the CHF experiment to investigate the pressure effect on the CHF under zero-flow and low-flow conditions for a wide range of system pressures. Also, two vertical annuli with the same geometry have been used to investigate the axial heat flux distributions on the CHF. This report summarizes the experimental results and provides the CHF data that can be used for the development for CHF correlation and a thermal hydraulic analysis code. The CHF data have been collected for system pressures ranging from 0.57 to 15.15 MPa, mass flux 0 and from 200 to 650 kg/m2s, inlet subcooling from 75 to 360 kJ/kg and exit quality from 0.07 to 0.57. At low-flow conditions, the total number of data are 242 and 290 with uniformly heated- and non-uniformly heated test sections, respectively. 41 and 94 CHF data are generated with uniformly heated- and non-uniformly heated test sections, respectively, in zero-flow CHF experiments that are performed by blocking test section bottoms. The CHF experiment result shows that the effects of system pressure, mass flux and inlet subcooling are consistent with conventional understandings and similar to those for round tubes. The behavior of the CHF is relatively complex at low pressures. Also, the effects of axial heat flux profile are large at low-pressure conditions
ACORN—A new method for generating sequences of uniformly distributed Pseudo-random Numbers
Wikramaratna, R. S.
1989-07-01
A new family of pseudo-random number generators, the ACORN ( additive congruential random number) generators, is proposed. The resulting numbers are distributed uniformly in the interval [0, 1). The ACORN generators are defined recursively, and the ( k + 1)th order generator is easily derived from the kth order generator. Some theorems concerning the period length are presented and compared with existing results for linear congruential generators. A range of statistical tests are applied to the ACORN generators, and their performance is compared with that of the linear congruential generators and the Chebyshev generators. The tests show the ACORN generators to be statistically superior to the Chebyshev generators, while being statistically similar to the linear congruential generators. However, the ACORN generators execute faster than linear congruential generators for the same statistical faithfulness. The main advantages of the ACORN generator are speed of execution, long period length, and simplicity of coding.
International Nuclear Information System (INIS)
Chen Liang; Zhang Wan-Rong; Jin Dong-Yue; Shen Pei; Xie Hong-Yun; Ding Chun-Bao; Xiao Ying; Sun Bo-Tao; Wang Ren-Qing
2011-01-01
A method of non-uniform finger spacing is proposed to enhance thermal stability of a multiple finger power SiGe heterojunction bipolar transistor under different power dissipations. Temperature distribution on the emitter fingers of a multi-finger SiGe heterojunction bipolar transistor is studied using a numerical electro-thermal model. The results show that the SiGe heterojunction bipolar transistor with non-uniform finger spacing has a small temperature difference between fingers compared with a traditional uniform finger spacing heterojunction bipolar transistor at the same power dissipation. What is most important is that the ability to improve temperature non-uniformity is not weakened as power dissipation increases. So the method of non-uniform finger spacing is very effective in enhancing the thermal stability and the power handing capability of power device. Experimental results verify our conclusions. (interdisciplinary physics and related areas of science and technology)
Long GRBs sources population non-uniformity
Arkhangelskaja, Irene
Long GRBs observed in the very wide energy band. It is possible to separate two subsets of GRBs with high energy component (E > 500 MeV) presence. First type events energy spectra in low and high energy intervals are similar (as for GRB 021008) and described by Band, power law or broken power law models look like to usual bursts without emission in tens MeV region. For example, Band spectrum of GRB080916C covering 6 orders of magnitude. Second ones contain new additional high energy spectral component (for example, GRB 050525B and GRB 090902B). Both types of GRBs observed since CGRO mission beginning. The low energy precursors existence are typical for all types bursts. Both types of bursts temporal profiles can be similar in the various energy regions during some events or different in other cases. The absence of hard to soft evolution in low energy band and (or) presence of high energy precursors for some events are the special features of second class of GRBs by the results of preliminary data analysis and this facts gives opportunities to suppose differences between these two GRBs subsets sources. Also the results of long GRB redshifts distribution analysis have shown its shape contradiction to uniform population objects one for our Metagalaxy to both total and various redshifts definition methods GRBs sources samples. These evidences allow making preliminary conclusion about non-uniformity of long GRBs sources population.
Nurses' uniform color and feelings/emotions in school-aged children receiving health care.
Albert, Nancy M; Burke, Jane; Bena, James F; Morrison, Shannon M; Forney, Jennifer; Krajewski, Susan
2013-04-01
Children may fear nurses wearing white uniforms. When emotions and uniform color were studied in 233 children, many positive emotions were most often associated with blue, bold pink-patterned, or yellow-patterned tops (all p ≤ .002). Negative emotions were not associated with uniform top colors (all p uniform color does not matter," 8 negative emotions were most often associated with white uniform color (p uniform tops were preferred. In conclusion, children's emotions were associated with nurse uniform color. Copyright © 2013 Elsevier Inc. All rights reserved.
Han, Xifeng; Zhou, Wen
2018-03-01
Optical vector radio-frequency (RF) signal generation based on optical carrier suppression (OCS) in one Mach-Zehnder modulator (MZM) can realize frequency-doubling. In order to match the phase or amplitude of the recovered quadrature amplitude modulation (QAM) signal, phase or amplitude pre-coding is necessary in the transmitter side. The detected QAM signals usually have one non-uniform phase distribution after square-law detection at the photodiode because of the imperfect characteristics of the optical and electrical devices. We propose to use optimal threshold of error decision for non-uniform phase contribution to reduce the bit error rate (BER). By employing this scheme, the BER of 16 Gbaud (32 Gbit/s) quadrature-phase-shift-keying (QPSK) millimeter wave signal at 36 GHz is improved from 1 × 10-3 to 1 × 10-4 at - 4 . 6 dBm input power into the photodiode.
Lee, Min Sun; Kim, Joong Hyun; Paeng, Jin Chul; Kang, Keon Wook; Jeong, Jae Min; Lee, Dong Soo; Lee, Jae Sung
2017-12-14
organ-based dosimetry. Errors at the organ-level were -6.71%, 2.17%, and 227.46% for the single VSV, multiple VSV, and organ-based dosimetry, respectively. Conclusion: The multiple VSV approach for heterogeneous media with non-uniform activity distributions offers fast personalized dosimetry at whole-body level, yielding results comparable to those of the direct Monte Carlo approach. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Uniform access to clinical data in a distributed environment. Radiology
International Nuclear Information System (INIS)
Adelhard, K.; Swoboda, N.; Nissen-Meyer, S.; Reiser, M.
1999-01-01
Purpose: Providing medical reports on wards and ambulatory settings in electronic form can improve the quality of health care delivery. Radiology was chosen as an example to demonstrate how to implement uniform access to clinical data in a hospital. Method: Medical professionals at the university hospital in Munich, Grosshadern, have access to all radiological reports of their patients. Web browsers are used as a front end. A centralized administration of users and patients is in place. Results: Centralized access control and patient selection guarantee uniform access to all applicable data via intranet and controls access rights. The high acceptance of this service is reflected by the high number of 150 requests per day. Discussion: Access to radiological reports within the Grosshadern University Clinics was enabled via web browsers in a short time. The high acceptance of the system also proves its easy use. Integration of the system in a centralized user and patient identification system supports the unified access to clinical data. (orig.) [de
International Nuclear Information System (INIS)
Ganeshan, B.; Miles, K.A.; Young, R.C.D.; Chatwin, C.R.
2007-01-01
Aim: To determine how hepatic entropy and uniformity of computed tomography (CT) images of the liver change after the administration of contrast material and to assess whether these additional parameters are more sensitive to tumour-related changes in the liver than measurements of hepatic attenuation or perfusion. Materials and methods: Hepatic attenuation, entropy, uniformity, and perfusion were measured using multi-phase CT following resection of colorectal cancer. Based on conventional CT and fluorodeoxyglucose positron emission tomography, 12 patients were classified as having no evidence of malignancy, eight with extra-hepatic tumours only, and eight with metastatic liver disease. Results: Hepatic attenuation and entropy increased after CM administration whereas uniformity decreased. Unlike hepatic attenuation, entropy and uniformity changed maximally in the arterial phase. No significant differences in hepatic perfusion or attenuation were found between patient groups, whereas arterial-phase entropy was lower (p = 0.034) and arterial-phase uniformity was higher (p = 0.034) in apparently disease-free areas of liver in patients with hepatic metastases compared with those with no metastases. Conclusion: Temporal changes in hepatic entropy and uniformity differ from those for hepatic attenuation. By reflecting the distribution of hepatic enhancement, these additional parameters are more sensitive to tumour-related changes in the liver than measurements of hepatic attenuation or perfusion
International Nuclear Information System (INIS)
Manglos, S.H.; Jaszczak, R.J.; Floyd, C.E.
1988-01-01
A method is developed to improve quantitation in SPECT imaging by using an attenuation compensation method which includes the correct non-uniform attenuation spatial distribution (''map''). The method is based on the technique of weighted back projection, previously developed for uniform attenuation. The method is tested by imaging a non-uniform phantom, reconstructing with the known attenuation map, and quantitatively comparing the resultant image with the known activity distribution. Reconstructed image profiles are dramatically improved in comparison to reconstructions without compensation or with an assumed uniform attenuation map. Contrast measurements further quantify the improvement. Line spread function distortions seen previously in non-uniform geometries are essentially eliminated by the method. Therefore, the method appears to be appropriate for these geometries, if the non-uniform map can be determined. Some additional image distortions introduced by the compensation method are noted and will require further study
Modelling refrigerant distribution in minichannel evaporators
DEFF Research Database (Denmark)
Brix, Wiebke
of the liquid and vapour in the inlet manifold. Combining non-uniform airflow and non-uniform liquid and vapour distribution shows that a non-uniform airflow distribution to some degree can be compensated by a suitable liquid and vapour distribution. Controlling the superheat out of the individual channels...... to be equal, results in a cooling capacity very close to the optimum. A sensitivity study considering parameter changes shows that the course of the pressure gradient in the channel is significant, considering the magnitude of the capacity reductions due to non-uniform liquid and vapour distribution and non......This thesis is concerned with numerical modelling of flow distribution in a minichannel evaporator for air-conditioning. The study investigates the impact of non-uniform airflow and non-uniform distribution of the liquid and vapour phases in the inlet manifold on the refrigerant mass flow...
International Nuclear Information System (INIS)
Soussaline, F.; Bidaut, L.; Raynaud, C.; Le Coq, G.
1983-06-01
An analytical solution to the SPECT reconstruction problem, where the actual attenuation effect can be included, was developped using a regularizing iterative method (RIM). The potential of this approach in quantitative brain studies when using a tracer for cerebrovascular disorders is now under evaluation. Mathematical simulations for a distributed activity in the brain surrounded by the skull and physical phantom studies were performed, using a rotating camera based SPECT system, allowing the calibration of the system and the evaluation of the adapted method to be used. On the simulation studies, the contrast obtained along a profile, was less than 5%, the standard deviation 8% and the quantitative accuracy 13%, for a uniform emission distribution of mean = 100 per pixel and a double attenuation coefficient of μ = 0.115 cm -1 and 0.5 cm -1 . Clinical data obtained after injection of 123 I (AMPI) were reconstructed using the RIM without and with cerebrovascular diseases or lesion defects. Contour finding techniques were used for the delineation of the brain and the skull, and measured attenuation coefficients were assumed within these two regions. Using volumes of interest, selected on homogeneous regions on an hemisphere and reported symetrically, the statistical uncertainty for 300 K events in the tomogram was found to be 12%, the index of symetry was of 4% for normal distribution. These results suggest that quantitative SPECT reconstruction for brain distribution is feasible, and that combined with an adapted tracer and an adequate model physiopathological parameters could be extracted
Rolling Force Prediction in Heavy Plate Rolling Based on Uniform Differential Neural Network
Directory of Open Access Journals (Sweden)
Fei Zhang
2016-01-01
Full Text Available Accurate prediction of the rolling force is critical to assuring the quality of the final product in steel manufacturing. Exit thickness of plate for each pass is calculated from roll gap, mill spring, and predicted roll force. Ideal pass scheduling is dependent on a precise prediction of the roll force in each pass. This paper will introduce a concept that allows obtaining the material model parameters directly from the rolling process on an industrial scale by the uniform differential neural network. On the basis of the characteristics that the uniform distribution can fully characterize the solution space and enhance the diversity of the population, uniformity research on differential evolution operator is made to get improved crossover with uniform distribution. When its original function is transferred with a transfer function, the uniform differential evolution algorithms can quickly solve complex optimization problems. Neural network structure and weights threshold are optimized by uniform differential evolution algorithm, and a uniform differential neural network is formed to improve rolling force prediction accuracy in process control system.
Irradiation uniformity of spherical targets by multiple uv beams from OMEGA
International Nuclear Information System (INIS)
Beich, W.; Dunn, M.; Hutchison, R.
1984-01-01
Direct-drive laser fusion demands extremely high levels of irradiation uniformity to ensure uniform compression of spherical targets. The assessment of illumination uniformity of targets irradiated by multiple beams from the OMEGA facility is made with the aid of multiple beams spherical superposition codes, which take into account ray tracing and absorption and a detailed knowledge of the intensity distribution of each beam in the target plane. In this report, recent estimates of the irradiation uniformity achieved with 6 and 12 uv beams of OMEGA will be compared with previous measurements in the IR, and predictions will be made for the uv illumination uniformity achievable with 24 beams of OMEGA
Divergence from, and Convergence to, Uniformity of Probability Density Quantiles
Directory of Open Access Journals (Sweden)
Robert G. Staudte
2018-04-01
Full Text Available We demonstrate that questions of convergence and divergence regarding shapes of distributions can be carried out in a location- and scale-free environment. This environment is the class of probability density quantiles (pdQs, obtained by normalizing the composition of the density with the associated quantile function. It has earlier been shown that the pdQ is representative of a location-scale family and carries essential information regarding shape and tail behavior of the family. The class of pdQs are densities of continuous distributions with common domain, the unit interval, facilitating metric and semi-metric comparisons. The Kullback–Leibler divergences from uniformity of these pdQs are mapped to illustrate their relative positions with respect to uniformity. To gain more insight into the information that is conserved under the pdQ mapping, we repeatedly apply the pdQ mapping and find that further applications of it are quite generally entropy increasing so convergence to the uniform distribution is investigated. New fixed point theorems are established with elementary probabilistic arguments and illustrated by examples.
International Nuclear Information System (INIS)
Oka, Tetsuo; Ichiju, Kana; Higa, Kazuya; Fukui, Satoshi; Ogawa, Jun; Sato, Takao; Yokoyama, Kazuya; Nakamura, Takashi
2017-01-01
Various experimental attempts have been made to obtain a uniform magnetic field in the space between face-to-face HTS bulk magnets that could possibly be utilized as NMR magnets. In general, the magnetic fields emitted from the magnetic pole surfaces containing HTS bulk magnets are characterized as non-uniform field distributions. Since the NMR magnets require highly uniform magnetic-field spaces, it has been assumed to be difficult to form uniform magnetic-field spaces between magnetic poles placed face-to-face. The authors modified the shapes of the magnetic-field distribution from convex to concave by attaching ferromagnetic iron plates to the pole surfaces. The magnets were then set face-to-face with various gaps of 30-70 mm, and the experimental data on magnetic-field uniformity was precisely measured in the space. In order to detect the NMR signals, the target performance for uniformity was set as 1,500 ppm throughout the 4-mm span on the x-axis, which is equivalent to performance in the past when the world's first detection of NMR signals was observed in the bore of hollow-type HTS bulk magnets. When we combined the concave and convex field distributions to compensate the uneven field distributions, the data of the best uniformity reached 358 ppm and 493 ppm in the 30 mm and 50 mm gaps, respectively, which exceeded the target value for the purpose of detecting the NMR signals within the space. Furthermore, it was shown that the field distributions change from concave to convex shape without any change at 1.1 T in the range from 7 to 11 mm in the 30-mm gap, indicating that the distributions are uniform. This suggests the possibility that the uniform magnetic-field space between the HTS bulk magnets set face-to-face expands. (author)
Preparation of uniform porous hydroxyapatite biomaterials by a new method
International Nuclear Information System (INIS)
Tang Yuejun; Tang Yuefeng; Lv Chuntang; Zhou Zhonghua
2008-01-01
In this paper, a new method of preparation of uniform porous hydroxyapatite biomaterials was reported. In order to obtain uniform porous biomaterials, disk samples were formed by the mixture of hydroxyapatite (HAP) powders and monodispersed polystyrene microspheres, and then HAP uniform porous materials with different diameter and different porosity (diameter: 436 ± 25 nm, 892 ± 20 nm and 1890 ± 20 nm, porosity: 46.5%, 41.3% and 34.7%, respectively) were prepared by sintering these disk samples at 1250 deg. C for 5 h. The pure phase of HAP powders fabricated by the hydrothermal technology was confirmed by X-ray diffraction (XRD). The surface and size distribution of pores in HAP biomaterials were observed by scanning electron microscopy (SEM), and the pore size distribution in porous HAP biomaterials was tested by mercury intrusion method
Two-dimensional hydrodynamics of uniform ion plasma in electrostatic field
International Nuclear Information System (INIS)
Mahdieh, M. H.; Gavili, A.
2005-01-01
Two-dimensional hydrodynamics of ion extraction from uniform quasi-neutral plasma, in electrostatic field has been simulated numerically. Experimentally, tunable pulsed lasers produce non-uniform plasma through stepwise photo-excitation and photo-ionization or multi-photo-ionization processes. Poisson's equation was solved simultaneously with the equations of mass, and momentum, assuming the Maxwell-Boltzmann distribution for electrons. In the calculation, the initial density profile at the boundaries has been assumed to be very steep for the ion plasma. In these calculations dynamics of electric potential and the ions density were assessed. The ion extraction time was also estimated from the calculation. The knowledge of spatial distribution of the ions across the cathode is very important for the practical purposes. In this simulation, the spatial distribution of the ion current density across the cathode as well as its temporal distribution was calculated
DEFF Research Database (Denmark)
Risager, Morten S.; Rudnick, Zeev
We study a variant of a problem considered by Dinaburg and Sinai on the statistics of the minimal solution to a linear Diophantine equation. We show that the signed ratio between the Euclidean norms of the minimal solution and the coefficient vector is uniformly distributed modulo one. We reduce ...
Non-uniform temperature gradients and thermal stresses produced ...
Indian Academy of Sciences (India)
thermally-induced stress distributions in a hollow steel sphere heated by a moving uniform ... models to evaluate temperatures according to the frictional heat generation, ... of these thermal effects include thermal stress, strain and deformation.
Grabner, Peter
2017-01-01
This volume is dedicated to Robert F. Tichy on the occasion of his 60th birthday. Presenting 22 research and survey papers written by leading experts in their respective fields, it focuses on areas that align with Tichy’s research interests and which he significantly shaped, including Diophantine problems, asymptotic counting, uniform distribution and discrepancy of sequences (in theory and application), dynamical systems, prime numbers, and actuarial mathematics. Offering valuable insights into recent developments in these areas, the book will be of interest to researchers and graduate students engaged in number theory and its applications.
Dynamic Uniform Scaling for Multiobjective Genetic Algorithms
DEFF Research Database (Denmark)
Pedersen, Gerulf; Goldberg, David E.
2004-01-01
Before Multiobjective Evolutionary Algorithms (MOEAs) can be used as a widespread tool for solving arbitrary real world problems there are some salient issues which require further investigation. One of these issues is how a uniform distribution of solutions along the Pareto non-dominated front c...
Dynamic Uniform Scaling for Multiobjective Genetic Algorithms
DEFF Research Database (Denmark)
Pedersen, Gerulf; Goldberg, D.E.
2004-01-01
Before Multiobjective Evolutionary Algorithms (MOEAs) can be used as a widespread tool for solving arbitrary real world problems there are some salient issues which require further investigation. One of these issues is how a uniform distribution of solutions along the Pareto non-dominated front can...
Stable and efficient retrospective 4D-MRI using non-uniformly distributed quasi-random numbers
Breuer, Kathrin; Meyer, Cord B.; Breuer, Felix A.; Richter, Anne; Exner, Florian; Weng, Andreas M.; Ströhle, Serge; Polat, Bülent; Jakob, Peter M.; Sauer, Otto A.; Flentje, Michael; Weick, Stefan
2018-04-01
The purpose of this work is the development of a robust and reliable three-dimensional (3D) Cartesian imaging technique for fast and flexible retrospective 4D abdominal MRI during free breathing. To this end, a non-uniform quasi random (NU-QR) reordering of the phase encoding (k y –k z ) lines was incorporated into 3D Cartesian acquisition. The proposed sampling scheme allocates more phase encoding points near the k-space origin while reducing the sampling density in the outer part of the k-space. Respiratory self-gating in combination with SPIRiT-reconstruction is used for the reconstruction of abdominal data sets in different respiratory phases (4D-MRI). Six volunteers and three patients were examined at 1.5 T during free breathing. Additionally, data sets with conventional two-dimensional (2D) linear and 2D quasi random phase encoding order were acquired for the volunteers for comparison. A quantitative evaluation of image quality versus scan times (from 70 s to 626 s) for the given sampling schemes was obtained by calculating the normalized mutual information (NMI) for all volunteers. Motion estimation was accomplished by calculating the maximum derivative of a signal intensity profile of a transition (e.g. tumor or diaphragm). The 2D non-uniform quasi-random distribution of phase encoding lines in Cartesian 3D MRI yields more efficient undersampling patterns for parallel imaging compared to conventional uniform quasi-random and linear sampling. Median NMI values of NU-QR sampling are the highest for all scan times. Therefore, within the same scan time 4D imaging could be performed with improved image quality. The proposed method allows for the reconstruction of motion artifact reduced 4D data sets with isotropic spatial resolution of 2.1 × 2.1 × 2.1 mm3 in a short scan time, e.g. 10 respiratory phases in only 3 min. Cranio-caudal tumor displacements between 23 and 46 mm could be observed. NU-QR sampling enables for stable 4D
Improvement of illumination uniformity for LED flat panel light by using micro-secondary lens array.
Lee, Hsiao-Wen; Lin, Bor-Shyh
2012-11-05
LED flat panel light is an innovative lighting product in recent years. However, current flat panel light products still contain some drawbacks, such as narrow lighting areas and hot spots. In this study, a micro-secondary lens array technique was proposed and applied for the design of the light guide surface to improve the illumination uniformity. By using the micro-secondary lens array, the candela distribution of the LED flat panel light can be adjusted to similar to batwing distribution to improve the illumination uniformity. The experimental results show that the enhancement of the floor illumination uniformity is about 61%, and that of the wall illumination uniformity is about 20.5%.
International Nuclear Information System (INIS)
Reynolds, W.D.; Gillham, R.W.; Cherry, J.A.
1982-01-01
The validity of using a distribution coefficient (Ksub(d)) in the mathematical prediction of strontium and cesium transport through uniform saturated sand was investigated by comparing measured breakthrough curves with curves of simulations using the advection-dispersion and the advection equations. Values for Ksub(d) were determined by batch equilibration tests and, indirectly, by fitting the mathematical model to breakthrough data from column experiments. Although the advection-dispersion equation accurately represented the breakthrough curves for two nonreactive solutes (chloride and tritium), neither it nor the advection equation provided close representations of the strontium and cesium curves. The simulated breakthrough curves for strontium and cesium were nearly symmetrical, whereas the data curves were very asymmetrical, with long tails. Column experiments with different pore-water velocities indicated that the shape of the normalized breakthrough curves was not sensitive to velocity. This suggests that the asymmetry of the measured curves was the result of nonlinear partitioning of the cations between the solid and liquid phases, rather than nonequilibrium effects. The results indicate that the distribution coefficient, when used in advection-dispersion models for prediction of the migration of strontium and cesium in field situations, can result in significant error
International Nuclear Information System (INIS)
Hung, Tran Van; Satoh, Daiki; Takahashi, Fumiaki; Tsuda, Shuichi; Endo, Akira; Saito, Kimiaki; Yamaguchi, Yasuhiro
2005-02-01
Age-dependent dose conversion coefficients for external exposure to photons emitted by radionuclides uniformly distributed in air were calculated. The size of the source region in the calculation was assumed to be effectively semi-infinite in extent. Firstly, organ doses were calculated with a series of age-specific MIRD-5 type phantoms using MCNP code, a Monte Carlo transport code. The calculations were performed for mono-energetic photon sources of twelve energies from 10 keV to 5 MeV and for phantoms of newborn, 1, 5, 10 and 15 years, and adult. Then, the effective doses to the different age-phantoms from the mono-energetic photon sources were estimated based on the obtained organ doses. The calculated effective doses were used to interpolate the conversion coefficients of the effective doses for 160 radionuclides, which are important for dose assessment of nuclear facilities. In the calculation, energies and intensities of emitted photons from radionuclides were taken from DECDC, a recent compilation of decay data for radiation dosimetry developed at JAERI. The results are tabulated in the form of effective dose per unit concentration and time (Sv per Bq s m -3 ). (author)
Verweij, A P
1998-01-01
Electrical measurements on samples of superconducting cables are usually performed in order to determine the critical current $I_c$ and the n-value, assuming that the voltage U at the transition from the superconducting to the normal state follows the power law, U\\sim($I/I_c$)$^n$. An accurate measurement of $I_c$ and n demands, first of all, good control of temperature and field, and precise measurement of current and voltage. The critical current and n-value of a cable are influenced by the self-field of the cable, an effect that has to be known in order to compare the electrical characteristics of the cable with those of the strands from which it is made. The effect of the self-field is dealt with taking into account the orientation and magnitude of the applied field and the n-value of the strands. An important source of inaccuracy is related to the distribution of the currents among the strands. Non-uniform distributions, mainly caused by non-equal resistances of the connections between the strands of the...
Mrazek, F.C.; Smaga, J.A.; Battles, J.E.
1981-01-19
A positive electrode for a secondary electrochemical cell is described wherein an electrically conductive current collector is in electrical contact with a particulate mixture of gray cast iron and an alkali metal sulfide and an electrolyte including alkali metal halides or alkaline earth metal halides. Also present may be a transition metal sulfide and graphite flakes from the conversion of gray cast iron to iron sulfide. Also disclosed is a method of distributing carbon flakes in a cell wherein there is formed an electrochemical cell of a positive electrode structure of the type described and a suitable electrolyte and a second electrode containing a material capable of alloying with alkali metal ions. The cell is connected to a source of electrical potential to electrochemically convert gray cast iron to an iron sulfide and uniformly to distribute carbon flakes formerly in the gray cast iron throughout the positive electrode while forming an alkali metal alloy in the negative electrode. Also disclosed are compositions useful in preparing positive electrodes.
International Nuclear Information System (INIS)
Golota, V.I.; Zavada, L.M.; Kotyukov, O.V.; Kudin, D.V.; Rodionov, S.V.; Pis'menetskoj, A.S.; Dotsenko, Yu.V.
2010-01-01
The barrierless gas discharge of negative polarity with strongly non-uniform distribution of electrical field in the methanol and ethanol vapour was studied. It is shown that level of methanol and ethanol conversion depended from power consumed by the discharge and exposition time for gas mixture in discharge zone. The condition for deep conversion of the methanol and ethanol vapours were determined. The water and carbon dioxide are the end products for the methanol and ethanol conversion. Formaldehyde and formic acid are the intermediates products in the conversion of methanol. And ethanol has a number of different compounds, including acetic acid, acetaldehyde, etc.
Assessment indices for uniform and non-uniform thermal environments
Institute of Scientific and Technical Information of China (English)
2008-01-01
Different assessment indices for thermal environments were compared and selected for proper assessment of indoor thermal environments.30 subjects reported their overall thermal sensation,thermal comfort,and thermal acceptability in uniform and non-uniform conditions.The results show that these three assessment indices provide equivalent evaluations in uniform environments.However,overall thermal sensation differs from the other two indices and cannot be used as a proper index for the evaluation of non-uniform environments.The relationship between the percentage and the mean vote for each index is established.
An analysis of the uniform core experiment
Energy Technology Data Exchange (ETDEWEB)
Waterson, R H
1973-10-15
This report describes an analysis of the Uniform Core of HITREX using the WIMS E codes, and presents the results of theory/experiment comparisons. The overall picture is one of good agreement for core reaction rate distributions, but theory umderestimating k{sub eff} by about 1.5% {delta}k/k.
Non-uniformly sampled grids in double pole coordinate system for freeform reflector construction
Ma, Donglin; Pacheco, Shaun; Feng, Zexin; Liang, Rongguang
2015-08-01
We propose a new method to design freeform reflectors by nonuniformly sampling the source intensity distribution in double pole coordinate system. In double pole coordinate system, there is no pole for the whole hemisphere because both poles of the spherical coordinate system are moved to southernmost point of the sphere and overlapped together. With symmetric definition of both angular coordinates in the modified double pole coordinate system, a better match between the source intensity distribution and target irradiance distribution can be achieved for reflectors with large acceptance solid angle, leading to higher light efficiency and better uniformity on the target surface. With non-uniform sampling of the source intensity, we can design circular freeform reflector to obtain uniform rectangular illumination pattern. Aided by the feedback optimization, the freeform reflector can achieve the collection efficiency for ideal point source over 0.7 and relative standard deviation (RSD) less than 0.1.
Analysis and Optimization for Uniformity of Magnetic Field Driving the Giant Magnetostriction
International Nuclear Information System (INIS)
Wang, L; Ye, H; Liu, Y T; Yao, S M
2006-01-01
Giant magnetostriction actuator based on material Tb0.27Dy0.73Fe2 and electromagnetic transform has characteristics of high frequency response, large output power and etc, but it has a high demand for the uniformity of magnetic field driver and magnetic intensity. Object to the problem, a multi-scale external concavity structure is proposed, by means of inducting the hollow column coil structure, building the model of coil magnetic distribution and analyzing by finite element analysis method. The analysis results show that uniformity of the model magnetic field is dependent upon magnetic intensity and scales, and the boundary condition of material. As the scale increases, magnetic uniformity is enhanced, but the magnetic intensity is decreased. Taking consideration both of magnetic field distribution and magnetic intensity, threescale structure is determined as optimum structure
Distribution uniformity of laser-accelerated proton beams
Zhu, Jun-Gao; Zhu, Kun; Tao, Li; Xu, Xiao-Han; Lin, Chen; Ma, Wen-Jun; Lu, Hai-Yang; Zhao, Yan-Ying; Lu, Yuan-Rong; Chen, Jia-Er; Yan, Xue-Qing
2017-09-01
Compared with conventional accelerators, laser plasma accelerators can generate high energy ions at a greatly reduced scale, due to their TV/m acceleration gradient. A compact laser plasma accelerator (CLAPA) has been built at the Institute of Heavy Ion Physics at Peking University. It will be used for applied research like biological irradiation, astrophysics simulations, etc. A beamline system with multiple quadrupoles and an analyzing magnet for laser-accelerated ions is proposed here. Since laser-accelerated ion beams have broad energy spectra and large angular divergence, the parameters (beam waist position in the Y direction, beam line layout, drift distance, magnet angles etc.) of the beamline system are carefully designed and optimised to obtain a radially symmetric proton distribution at the irradiation platform. Requirements of energy selection and differences in focusing or defocusing in application systems greatly influence the evolution of proton distributions. With optimal parameters, radially symmetric proton distributions can be achieved and protons with different energy spread within ±5% have similar transverse areas at the experiment target. Supported by National Natural Science Foundation of China (11575011, 61631001) and National Grand Instrument Project (2012YQ030142)
Estimation of current density distribution under electrodes for external defibrillation
Directory of Open Access Journals (Sweden)
Papazov Sava P
2002-12-01
Full Text Available Abstract Background Transthoracic defibrillation is the most common life-saving technique for the restoration of the heart rhythm of cardiac arrest victims. The procedure requires adequate application of large electrodes on the patient chest, to ensure low-resistance electrical contact. The current density distribution under the electrodes is non-uniform, leading to muscle contraction and pain, or risks of burning. The recent introduction of automatic external defibrillators and even wearable defibrillators, presents new demanding requirements for the structure of electrodes. Method and Results Using the pseudo-elliptic differential equation of Laplace type with appropriate boundary conditions and applying finite element method modeling, electrodes of various shapes and structure were studied. The non-uniformity of the current density distribution was shown to be moderately improved by adding a low resistivity layer between the metal and tissue and by a ring around the electrode perimeter. The inclusion of openings in long-term wearable electrodes additionally disturbs the current density profile. However, a number of small-size perforations may result in acceptable current density distribution. Conclusion The current density distribution non-uniformity of circular electrodes is about 30% less than that of square-shaped electrodes. The use of an interface layer of intermediate resistivity, comparable to that of the underlying tissues, and a high-resistivity perimeter ring, can further improve the distribution. The inclusion of skin aeration openings disturbs the current paths, but an appropriate selection of number and size provides a reasonable compromise.
Errors due to non-uniform distribution of fat in dual X-ray absorptiometry of the lumbar spine
International Nuclear Information System (INIS)
Tothill, P.; Pye, D.W.
1992-01-01
Errors in spinal dual X-ray absorptiometry (DXA) were studied by analysing X-ray CT scans taken for diagnostic purposes on 20 patients representing a wide range of fat content. The mean difference between the fat thickness over the vertebral bodies and that over a background area in antero-posterior (AP) scanning was 6.7 ± 8.1 mm for men and 13.4 ± 4.7 mm for women. For AP scanning a non-uniform fat distribution leads to a mean overestimate of 0.029 g/cm 2 for men and 0.057 g/cm 2 for women. The error exceeded 0.1 g/cm 2 in 10% of slices. For lateral scanning the error exceeded 0.1 g/cm 2 (about 15% of normal) in a quarter of slices. (author)
Cybulski, Olgierd; Jakiela, Slawomir; Garstecki, Piotr
2015-12-01
The simplest microfluidic network (a loop) comprises two parallel channels with a common inlet and a common outlet. Recent studies that assumed a constant cross section of the channels along their length have shown that the sequence of droplets entering the left (L) or right (R) arm of the loop can present either a uniform distribution of choices (e.g., RLRLRL...) or long sequences of repeated choices (RRR...LLL), with all the intermediate permutations being dynamically equivalent and virtually equally probable to be observed. We use experiments and computer simulations to show that even small variation of the cross section along channels completely shifts the dynamics either into the strong preference for highly grouped patterns (RRR...LLL) that generate system-size oscillations in flow or just the opposite-to patterns that distribute the droplets homogeneously between the arms of the loop. We also show the importance of noise in the process of self-organization of the spatiotemporal patterns of droplets. Our results provide guidelines for rational design of systems that reproducibly produce either grouped or homogeneous sequences of droplets flowing in microfluidic networks.
Velocity Distributions in Inelastic Granular Gases with Continuous Size Distributions
International Nuclear Information System (INIS)
Li Rui; Li Zhi-Hao; Zhang Duan-Ming
2011-01-01
We study by numerical simulation the property of velocity distributions of granular gases with a power-law size distribution, driven by uniform heating and boundary heating. It is found that the form of velocity distribution is primarily controlled by the restitution coefficient η and q, the ratio between the average number of heatings and the average number of collisions in the system. Furthermore, we show that uniform and boundary heating can be understood as different limits of q, with q ≫ 1 and q ≤ 1, respectively. (general)
Effect of non-uniform surface resistance on the quality factor of superconducting niobium cavity
Tan, Weiwei; Lu, Xiangyang; Yang, Ziqin; Zhao, Jifei; Yang, Deyu; Yang, Yujia
2016-08-01
The formula Rs = G /Q0 is commonly used in the calculation of the surface resistance of radio frequency niobium superconducting cavities. The applying of such equation is under the assumption that surface resistance is consistent over the cavity. However, the distribution of the magnetic field varies over the cavity. The magnetic field in the equator is much higher than that in the iris. According to Thermal Feedback Theory, it leads non-uniform distribution of the density of heat flux, which results in a different temperature distribution along the cavity inter surface. The BCS surface resistance, which depends largely on the temperature, is different in each local inner surface. In this paper, the effect of surface non-uniform resistance on the quality factor has been studied, through the calculation of Q0 in the original definition of it. The results show that it is necessary to consider the non-uniform distribution of magnetic field when the accelerating field is above 20 MV/m for TESLA cavities. Also, the effect of inhomogeneity of residual resistance on the quality factor is discussed. Its distribution barely affects the quality factor.
Alternative methods for evaluation of non-uniformity in nuclear medicine images
International Nuclear Information System (INIS)
Rasaneh, S.; Rajabi, H.; Hajizadeh, E.
2005-01-01
Non-uniformity test is the most essential in daily quality control procedures of nuclear medicine equipment's. However, the calculation of non-uniformity is hindered due to high level of noise in nuclear medicine data. Non-uniformity may be considered as a type of systematic error while noise is certainly a random error. The present methods of uniformity evaluation are not able to distinguish between systematic and random error and therefore produce incorrect results when noise is significant. In the present study, two hypothetical methods have been tested for evaluation of non-uniformity in nuclear medicine images. Materials and Methods: Using the Monte Carlo method, uniform and non-uniform flood images of different matrix sizes and different counts were generated. The uniformity of the images was calculated using the conventional method and proposed methods. The results were compared with the known non-uniformity data of simulated images. Results: It was observed that the value of integral uniformity never went below the recommended values except in small matrix size of high counts (more than 80 millions counts). The differential uniformity was quite insensitive to the degree of non-uniformity in large matrix size. Matrix size of 64*64 was only found to be suitable for the calculation of differential uniformity. It was observed that in uniform images, a small amount of non-uniformity changes the p-value of Kolmogorov-Smirnov test and noise amplitude of fast fourier transformation test significantly while the conventional methods failed to detect the nonuniformity. Conclusion: The conventional methods do not distinguish noise, which is always present in the data and occasional non-uniformity at low count density. In a uniform intact flood image, the difference between maximum and minimum pixel count (the value of integral uniformity) is much more than the recommended values for non-uniformity. After filtration of image, this difference decreases, but remains high
Directory of Open Access Journals (Sweden)
Marcus V. A. M. de Oliveira
2008-03-01
nitrogen (NO3- + NH4+. According to obtained results, the conclusions were as follows: there is no significant variation on distribution uniformity of nitrogen and potassium in the trickle irrigation system studied; longer periods of irrigation when in fertigation operation, improve uniformity distribution of the fertilizer, and the irrigation period after the fertilizer injection is finalized should be calculated to improve fertilizer distribution uniformity.
Planned studies of charge collection in non-uniformly irradiated Si and GaAs detectors
International Nuclear Information System (INIS)
Rosenfeld, A.; Reinhard, M.; Carolan, M.; Kaplan, G.; Lerch, M.; Alexiev, D.
1995-01-01
The aim of this project is to study the time and amplitude characteristics of silicon ion-implanted detectors non-uniformly irradiated with fast neutrons in order to predict their radiation behaviour in the LHC and space. It is expected in such detectors increases of the charge deficit due to trapping by large scale traps and transient time increases due to the reduction of the mobility. The theoretical model will be modified to describe the charge kinetics in the electrical field of the detector created by a non uniform space charge distribution. Experimental confirmation techniques are needed to develop non uniform predictable damage of silicon detectors using fast neutron sources (accelerators, reactors) and to study peculiarities of the charge transport in different parts of the detector. In parallel to experimental research will be started the theoretical development of the charge transport model for non-uniform distribution of space charge in the depletion layer (Neff). The model will include the linear distribution of Neff(y) along the detector as well as the change of sign of Neff (conversion from n to p type of silicon) inside the detector
Fiber optic based optical tomography sensor for monitoring plasma uniformity
International Nuclear Information System (INIS)
Benck, Eric C.; Etemadi, Kasra
2001-01-01
A new type of fiber optic based optical tomography sensor has been developed for in situ monitoring of plasma uniformity. Optical tomography inverts optical emission measurements into the actual plasma distribution without assuming radial symmetry. The new sensor is designed to operate with only two small windows and acquire the necessary data in less than a second. Optical tomography is being tested on an ICP-GEC RF plasma source. Variations in plasma uniformity are measured as a function of different plasma conditions
Directory of Open Access Journals (Sweden)
Yan Wei
2015-10-01
Full Text Available The uniform distribution and experimental design is employed to study the thermo-hydraulic characteristics of a heat exchanger, which consists of the rotor-assembled strands mounted in circular smooth tubes. The uniform distribution and experimental design parameters include multiple rotor parameters such as rotor diameters, rotor lead, and height of blade, with the aim of studying their influence on the PEC, that is, ( ( Nu z / Nu g / ( f g / f z 1 / 3 , which stands for the heat transfer and friction characteristics. The best matching schemes of rotor-assembled strand, which significantly improves PEC to 2.01, are given by the regression analysis of uniform distribution and experimental design table. The single-factor experiments are performed to compare a tube installed with different kinds of rotor-assembled strands with a smooth tube without any strands when the Reynolds number changes between 20,000 and 60,000. The experimental result is in good agreement with the result obtained by the regression analysis of uniform distribution and experimental design. It is shown that the rotor diameters play important role in the heat transfer, and the optimal PEC value is obtained under the case that the rotor diameter is 21 mm. The rotor lead also contributes to the improvement of heat transfer and its optimal value is 700 mm in this study. The Nusselt number, friction factor and PEC increase with the increase in blade height. It shows that the uniform distribution and experimental design is an efficient method to find out the optimal parameters.
Cooling water distribution system
Orr, Richard
1994-01-01
A passive containment cooling system for a nuclear reactor containment vessel. Disclosed is a cooling water distribution system for introducing cooling water by gravity uniformly over the outer surface of a steel containment vessel using an interconnected series of radial guide elements, a plurality of circumferential collector elements and collector boxes to collect and feed the cooling water into distribution channels extending along the curved surface of the steel containment vessel. The cooling water is uniformly distributed over the curved surface by a plurality of weirs in the distribution channels.
International Nuclear Information System (INIS)
Bhattacharyya, Pratip; Chakrabarti, Bikas K
2008-01-01
We study different ways of determining the mean distance (r n ) between a reference point and its nth neighbour among random points distributed with uniform density in a D-dimensional Euclidean space. First, we present a heuristic method; though this method provides only a crude mathematical result, it shows a simple way of estimating (r n ). Next, we describe two alternative means of deriving the exact expression of (r n ): we review the method using absolute probability and develop an alternative method using conditional probability. Finally, we obtain an approximation to (r n ) from the mean volume between the reference point and its nth neighbour and compare it with the heuristic and exact results
Uniformity testing: assessment of a centralized web-based uniformity analysis system.
Klempa, Meaghan C
2011-06-01
Uniformity testing is performed daily to ensure adequate camera performance before clinical use. The aim of this study is to assess the reliability of Beth Israel Deaconess Medical Center's locally built, centralized, Web-based uniformity analysis system by examining the differences between manufacturer and Web-based National Electrical Manufacturers Association integral uniformity calculations measured in the useful field of view (FOV) and the central FOV. Manufacturer and Web-based integral uniformity calculations measured in the useful FOV and the central FOV were recorded over a 30-d period for 4 cameras from 3 different manufacturers. These data were then statistically analyzed. The differences between the uniformity calculations were computed, in addition to the means and the SDs of these differences for each head of each camera. There was a correlation between the manufacturer and Web-based integral uniformity calculations in the useful FOV and the central FOV over the 30-d period. The average differences between the manufacturer and Web-based useful FOV calculations ranged from -0.30 to 0.099, with SD ranging from 0.092 to 0.32. For the central FOV calculations, the average differences ranged from -0.163 to 0.055, with SD ranging from 0.074 to 0.24. Most of the uniformity calculations computed by this centralized Web-based uniformity analysis system are comparable to the manufacturers' calculations, suggesting that this system is reasonably reliable and effective. This finding is important because centralized Web-based uniformity analysis systems are advantageous in that they test camera performance in the same manner regardless of the manufacturer.
Pattern optimization of compound optical film for uniformity improvement in liquid-crystal displays
Huang, Bing-Le; Lin, Jin-tang; Ye, Yun; Xu, Sheng; Chen, En-guo; Guo, Tai-Liang
2017-12-01
The density dynamic adjustment algorithm (DDAA) is designed to efficiently promote the uniformity of the integrated backlight module (IBLM) by adjusting the microstructures' distribution on the compound optical film (COF), in which the COF is constructed in the SolidWorks and simulated in the TracePro. In order to demonstrate the universality of the proposed algorithm, the initial distribution is allocated by the Bezier curve instead of an empirical value. Simulation results maintains that the uniformity of the IBLM reaches over 90% only after four rounds. Moreover, the vertical and horizontal full width at half maximum of angular intensity are collimated to 24 deg and 14 deg, respectively. Compared with the current industry requirement, the IBLM has an 85% higher luminance uniformity of the emerging light, which demonstrate the feasibility and universality of the proposed algorithm.
Cohn, Carl A.
1996-01-01
Shortly after implementing a mandatory school uniform policy, the Long Beach (California) Public Schools can boast 99% compliance and a substantial reduction in school crime. The uniforms can't be confused with gang colors, save parents money, and help identify outsiders. A sidebar lists ingredients for a mandatory uniform policy. (MLH)
Uniform risk functionals for characterization of strong earthquake ground motions
International Nuclear Information System (INIS)
Anderson, J.G.; Trifunac, M.D.
1978-01-01
A uniform risk functional (e.g., Fourier spectrum, response spectrum, duration, etc.) is defined so that the probability that it is exceeded by some earthquake during a selected period of time is independent of the frequency of seismic waves. Such a functional is derived by an independent calculation, at each frequency, for the probability that the quantity being considered will be exceeded. Different aspects of the seismicity can control the amplitude of a uniform risk functional in different frequency ranges, and a uniform risk functional does not necessarily describe the strong shaking from any single earthquake. To be useful for calculating uniform risk functionals, a scaling relationship must provide an independent estimate of amplitudes of the functional in several frequency bands. The scaling relationship of Trifunac (1976) for Fourier spectra satisfies this requirement and further describes the distribution of spectral amplitudes about the mean trend; here, it is applied to find uniform risk Fourier amplitude spectra. In an application to finding the uniform risk spectra at a realistic site, this method is quite sensitive to the description of seismicity. Distinct models of seismicity, all consistent with our current level of knowledge of an area, can give significantly different risk estimates
Dowling-Sendor, Benjamin
2002-01-01
Reviews a recent decision in "Littlefield" by the 5th Circuit upholding a school uniform policy. Advises board member who wish to adopt a school uniform policy to solicit input from parents and students, research the experiences of other school districts with uniform policies, and articulate the interests they wish to promote through uniform…
Dynamics of leaching a uniformly fissured ore body
International Nuclear Information System (INIS)
Ignatov, A.A.; Proskurin, S.A.
1987-01-01
Mathematical simulation was used to study the dynamics of mass transfer during the percolation of a reagent solution through a packing of coarse ore particles. The uniformly fissured ore body was represented by a cubic packing of spherical particles of constant radius, formed from a chemically inert silicate cement with a uniformly distributed soluble mineral component. The rate of percolation of the reagent through the packing was constant. The proposed model can be used to find the conditions for underground hydrodynamic leaching. The rate of non-catalytic solid-liquid reaction was deduced on the basis of both the kinetics of dissolution of the mineral component of the ore and the rate of diffusion of the dissolved substance
Non-uniform current distribution in a force-cooled superconductor under changing magnetic field
International Nuclear Information System (INIS)
Koizumi, Norikiyo
2000-02-01
Strands in a large current force-cooled superconductor, referred to a CICC (cable-in-conduit conductor) hereafter, are coated with formvar (insulated layer) or chrome plating (high resistive layer) to reduce coupling current loss due to magnetic field variation. The author first carried out an experiment of the large superconducting coil consisting of such CICCs for demonstration of their applicability to a large superconducting coil. These CICCs exhibited instability, i.e. the normal zone propagation with thermal runaway (quench), at 1/20 and 1/5 of the expected conductor critical currents, respectively. The author constructed the database of this instability and studies its reason through experimental and theoretical investigations and then finds such instability is caused as a result of non-uniform current distribution in the conductor. Joule heating loss at electrical connections at the ends of the conductor should be small. Therefore, the strands in the CICC are electrically connected from each other with low resistance there. Circulation current is induced in the loop composed of the strands electrically connected at the ends of the conductor if its leakage magnetic flux is not completely vanished. The non-uniform current distribution is caused as a result of superimposition of the circulation and transport currents. The strand carrying large current becomes the normal state when it reaches or approaches to its critical current. Thus, the strands are twisted in order to vanish the leakage magnetic flux. The instability due to the current imbalance was not observed in the middle-scale coil (an element coil, such as a single double-pancake, of a large superconducting coil) consisting of the conductor in which the formvar-coated strands were twisted as above-mentioned. Consequently, it was believed that the leakage magnetic flux could be vanished by the normal twisting. However, the magnetic field increases in a large coil as a result of piling element coils
International Nuclear Information System (INIS)
Maciejewski, B.; Rodney Withers, H.
2004-01-01
The exploitation of a number of current clinical trials and reports on outcomes after radiation therapy (i.e. breast, head and neck, prostate) in clinical practice reflects many limitations for conventional techniques and dose-fractionation schedules and for 'average' conclusions. Even after decades of evolution of radiation therapy we still do not know how to optimize treatment for the individual patient and only have 'averages' and ill-defined 'probabilities' to guide treatment prescription. Wide clinical and biological heterogeneity within the groups of patients recruited into clinical trials with a few-fold variation in tumour volume within one stage of disease is obvious. Basic radiobiological guidelines concerning average cell killing of uniformly distributed and equally radiosensitive tumour cells arose from elegant but idealistic in vitro experiments and seem to be of uncertain validity. Therefore, we are confronted with more dilemmas than dogmas. Nonlinearity and in homogeneity of human tumour pattern and response to irradiation are discussed. The purpose of this paper is to present and discuss various aspects of non-uniform tumour cell targeted radiotherapy using conformal and dose intensity modulated techniques. (author)
Directory of Open Access Journals (Sweden)
Manli Wang
2015-05-01
Full Text Available The present study establishes a visualization method for the measurement of the distribution and localization of protein/peptide constituents within a single poly-lactide-co-glycolide (PLGA microsphere using synchrotron radiation–based Fourier-transform infrared spectromicroscopy (SR-FTIR. The representative infrared wavenumbers specific for protein/peptide (Exenatide and excipient (PLGA were identified and chemical maps at the single microsphere level were generated by measuring and plotting the intensity of these specific bands. For quantitative analysis of the distribution within microspheres, Matlab software was used to transform the map file into a 3D matrix and the matrix values specific for the drug and excipient were extracted. Comparison of the normalized SR-FTIR maps of PLGA and Exenatide indicated that PLGA was uniformly distributed, while Exenatide was relatively non-uniformly distributed in the microspheres. In conclusion, SR-FTIR is a rapid, nondestructive and sensitive detection technology to provide the distribution of chemical constituents and functional groups in microparticles and microspheres.
Feng Sheng Qin; LianShouLiu
2002-01-01
The non-uniform longitudinal flow model (NUFM) proposed recently is extended to include also the transverse flow. The resulting longitudinally non-uniform collective expansion model (NUCEM) is applied to the calculation of rapidity distribution of kaons, lambdas and protons in relativistic heavy ion collisions at CERN-SPS energies. The model results are compared with the 200 A GeV/c S-S and 158 A GeV/c Pb-Pb collision data. The central dips observed in experiments are reproduced in a natural way. It is found that the depth of the central dip depends on the magnitude of the parameter e and the mass of produced particles, i.e. the non-uniformity of the longitudinal flow which is described by the parameter e determines the depth of the central dip for produced particles. Comparing with one-dimensional non-uniform longitudinal flow model, the rapidity distribution of lighter strange particle kaon also shows a dip due to the effect of transverse flow
The analysis of colour uniformity for a volumetric display based on a rotating LED array
International Nuclear Information System (INIS)
Wu, Jiang; Liu, Xu; Yan, Caijie; Xia, XinXing; Li, Haifeng
2011-01-01
There is a colour nonuniformity zone existing in three-dimensional (3D) volumetric displays which is based on the rotating colour light-emitting diode (LED) array. We analyse the reason for the colour nonuniformity zone by measuring the light intensity distribution and chromaticity coordinates of the LED in the volumetric display. Two boundaries of the colour nonuniformity zone are calculated. We measure the colour uniformities for a single cuboid of 3*3*4 voxels to display red, green, blue and white colour in different horizontal viewing angles, and for 64 cuboids distributed in the whole cylindrical image space with a fixed viewpoint. To evaluate the colour uniformity of a 3D image, we propose three evaluation indices of colour uniformity: the average of colour difference, the maximum colour difference and the variance of colour difference. The measurement results show that the character of colour uniformity is different for the 3D volumetric display and the two-dimensional display
High-voltage electrode optimization towards uniform surface treatment by a pulsed volume discharge
International Nuclear Information System (INIS)
Ponomarev, A V; Pedos, M S; Scherbinin, S V; Mamontov, Y I; Ponomarev, S V
2015-01-01
In this study, the shape and material of the high-voltage electrode of an atmospheric pressure plasma generation system were optimised. The research was performed with the goal of achieving maximum uniformity of plasma treatment of the surface of the low-voltage electrode with a diameter of 100 mm. In order to generate low-temperature plasma with the volume of roughly 1 cubic decimetre, a pulsed volume discharge was used initiated with a corona discharge. The uniformity of the plasma in the region of the low-voltage electrode was assessed using a system for measuring the distribution of discharge current density. The system's low-voltage electrode - collector - was a disc of 100 mm in diameter, the conducting surface of which was divided into 64 radially located segments of equal surface area. The current at each segment was registered by a high-speed measuring system controlled by an ARM™-based 32-bit microcontroller. To facilitate the interpretation of results obtained, a computer program was developed to visualise the results. The program provides a 3D image of the current density distribution on the surface of the low-voltage electrode. Based on the results obtained an optimum shape for a high-voltage electrode was determined. Uniformity of the distribution of discharge current density in relation to distance between electrodes was studied. It was proven that the level of non-uniformity of current density distribution depends on the size of the gap between electrodes. Experiments indicated that it is advantageous to use graphite felt VGN-6 (Russian abbreviation) as the material of the high-voltage electrode's emitting surface. (paper)
A universal algorithm to generate pseudo-random numbers based on uniform mapping as homeomorphism
International Nuclear Information System (INIS)
Fu-Lai, Wang
2010-01-01
A specific uniform map is constructed as a homeomorphism mapping chaotic time series into [0,1] to obtain sequences of standard uniform distribution. With the uniform map, a chaotic orbit and a sequence orbit obtained are topologically equivalent to each other so the map can preserve the most dynamic properties of chaotic systems such as permutation entropy. Based on the uniform map, a universal algorithm to generate pseudo random numbers is proposed and the pseudo random series is tested to follow the standard 0–1 random distribution both theoretically and experimentally. The algorithm is not complex, which does not impose high requirement on computer hard ware and thus computation speed is fast. The method not only extends the parameter spaces but also avoids the drawback of small function space caused by constraints on chaotic maps used to generate pseudo random numbers. The algorithm can be applied to any chaotic system and can produce pseudo random sequence of high quality, thus can be a good universal pseudo random number generator. (general)
A universal algorithm to generate pseudo-random numbers based on uniform mapping as homeomorphism
Wang, Fu-Lai
2010-09-01
A specific uniform map is constructed as a homeomorphism mapping chaotic time series into [0,1] to obtain sequences of standard uniform distribution. With the uniform map, a chaotic orbit and a sequence orbit obtained are topologically equivalent to each other so the map can preserve the most dynamic properties of chaotic systems such as permutation entropy. Based on the uniform map, a universal algorithm to generate pseudo random numbers is proposed and the pseudo random series is tested to follow the standard 0-1 random distribution both theoretically and experimentally. The algorithm is not complex, which does not impose high requirement on computer hard ware and thus computation speed is fast. The method not only extends the parameter spaces but also avoids the drawback of small function space caused by constraints on chaotic maps used to generate pseudo random numbers. The algorithm can be applied to any chaotic system and can produce pseudo random sequence of high quality, thus can be a good universal pseudo random number generator.
Even distribution/dividing of single-phase fluids by symmetric bifurcation of flow channels
International Nuclear Information System (INIS)
Liu, Hong; Li, Peiwen
2013-01-01
Highlights: ► We addressed an issue of distributing a flow to a number of flow channels uniformly. ► The flow distribution is accomplished through bifurcation of channels. ► Some key parameters to the flow distribution uniformity have been identified. ► Flow uniformity was studied for several versions of flow distributor designs. ► A novel fluid packaging device of high efficiency was provided. -- Abstract: This study addresses a fundamental issue of distributing a single-phase fluid flow into a number of flow channels uniformly. A basic mechanism of flow distribution is accomplished through bifurcation of channels that symmetrically split one flow channel into two downstream channels. Applying the basic mechanism, cascades flow distributions are designed to split one flow into a large number of downstream flows uniformly. Some key parameters decisive to the flow distribution uniformity in such a system have been identified, and the flow distribution uniformity of air was studied for several versions of flow distributor designs using CFD analysis. The effect of the key parameters of the flow channel designs to the flow distribution uniformity was investigated. As an example of industrial application, a novel fluid packaging device of high efficiency was proposed and some CFD analysis results for the device were provided. The optimized flow distributor makes a very good uniform flow distribution which will significantly improve the efficiency of fluid packaging. The technology is expected to be of great significance to many industrial devices that require high uniformity of flow distribution
Activation rate uniformity in a bilateral IVNAA facility for two anthropomorphic phantoms
Directory of Open Access Journals (Sweden)
Miri Hakimabad Hashem
2010-01-01
Full Text Available Activation rate uniformity is the first property which is considered in the design of a prompt γ-ray in vivo neutron activation analysis facility. Preliminary studies on the activation rate distribution in the body can be done by use of Monte Carlo codes, such as the MCNP. In this paper, different bilateral configurations of an IVNAA system are considered in order to improve the activation rate uniformity in a water phantom measuring 32 cm x 100 cm x 16 cm. In the best case, uniformity parameters are U = 1.003 and R = 1.67, with the mean activation rate of 1.85×10-6 cm-3. In more accurate calculations, the water phantom is replaced by a body model. The model in question is a 5 year-old ORNL phantom filled with just soft tissue. For uniformity studies, the internal organs are not simulated. Finally, uniformity parameters in this case are U = 1.005 and R = 12.2.
International Nuclear Information System (INIS)
Zheng, Y; Rana, S; Larson, G
2016-01-01
Purpose: To analyze the toxicity of uniform scanning proton therapy for lung cancer patients and its correlation with dose distribution. Methods: In this study, we analyzed the toxicity of 128 lung cancer patients, including 18 small cell lung cancer and 110 non small cell lung cancer patients. Each patient was treated with uniform scanning proton beams at our center using typically 2–4 fields. The prescription was typically 74 Cobalt gray equivalent (CGE) at 2 CGE per fraction. 4D Computerized Tomography (CT) scans were used to evaluate the target motion and contour the internal target volume, and repeated 3 times during the course of treatment to evaluate the need for plan adaptation. Toxicity data for these patients were obtained from the proton collaborative group (PCG) database. For cases of grade 3 toxicities or toxicities of interest such as esophagitis and radiation dermatitis, dose distributions were reviewed and analyzed in attempt to correlate the toxicity with radiation dose. Results: At a median follow up time of about 21 months, none of the patients had experienced Grade 4 or 5 toxicity. The most common adverse effect was dermatitis (81%: 52%-Grade 1, 28%-Grade 2, and 1% Grade 3), followed by fatigue (48%), Cough (46%), and Esophagitis (45%), as shown in Figure 1. Severe toxicities, such as Grade 3 dermatitis or pain of skin, had a clear correlation with high radiation dose. Conclusion: Uniform scanning proton therapy is well tolerated by lung cancer patients. Preliminary analysis indicates there is correlation between severe toxicity and high radiation dose. Understanding of radiation resulted toxicities and careful choice of beam arrangement are critical in minimizing toxicity of skin and other organs.
Energy Technology Data Exchange (ETDEWEB)
Zheng, Y; Rana, S; Larson, G [Procure Proton Therapy Center, Oklahoma City, OK (United States)
2016-06-15
Purpose: To analyze the toxicity of uniform scanning proton therapy for lung cancer patients and its correlation with dose distribution. Methods: In this study, we analyzed the toxicity of 128 lung cancer patients, including 18 small cell lung cancer and 110 non small cell lung cancer patients. Each patient was treated with uniform scanning proton beams at our center using typically 2–4 fields. The prescription was typically 74 Cobalt gray equivalent (CGE) at 2 CGE per fraction. 4D Computerized Tomography (CT) scans were used to evaluate the target motion and contour the internal target volume, and repeated 3 times during the course of treatment to evaluate the need for plan adaptation. Toxicity data for these patients were obtained from the proton collaborative group (PCG) database. For cases of grade 3 toxicities or toxicities of interest such as esophagitis and radiation dermatitis, dose distributions were reviewed and analyzed in attempt to correlate the toxicity with radiation dose. Results: At a median follow up time of about 21 months, none of the patients had experienced Grade 4 or 5 toxicity. The most common adverse effect was dermatitis (81%: 52%-Grade 1, 28%-Grade 2, and 1% Grade 3), followed by fatigue (48%), Cough (46%), and Esophagitis (45%), as shown in Figure 1. Severe toxicities, such as Grade 3 dermatitis or pain of skin, had a clear correlation with high radiation dose. Conclusion: Uniform scanning proton therapy is well tolerated by lung cancer patients. Preliminary analysis indicates there is correlation between severe toxicity and high radiation dose. Understanding of radiation resulted toxicities and careful choice of beam arrangement are critical in minimizing toxicity of skin and other organs.
Uniform deposition of size-selected clusters using Lissajous scanning
International Nuclear Information System (INIS)
Beniya, Atsushi; Watanabe, Yoshihide; Hirata, Hirohito
2016-01-01
Size-selected clusters can be deposited on the surface using size-selected cluster ion beams. However, because of the cross-sectional intensity distribution of the ion beam, it is difficult to define the coverage of the deposited clusters. The aggregation probability of the cluster depends on coverage, whereas cluster size on the surface depends on the position, despite the size-selected clusters are deposited. It is crucial, therefore, to deposit clusters uniformly on the surface. In this study, size-selected clusters were deposited uniformly on surfaces by scanning the cluster ions in the form of Lissajous pattern. Two sets of deflector electrodes set in orthogonal directions were placed in front of the sample surface. Triangular waves were applied to the electrodes with an irrational frequency ratio to ensure that the ion trajectory filled the sample surface. The advantages of this method are simplicity and low cost of setup compared with raster scanning method. The authors further investigated CO adsorption on size-selected Pt n (n = 7, 15, 20) clusters uniformly deposited on the Al 2 O 3 /NiAl(110) surface and demonstrated the importance of uniform deposition.
Uniform deposition of size-selected clusters using Lissajous scanning
Energy Technology Data Exchange (ETDEWEB)
Beniya, Atsushi; Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan); Hirata, Hirohito [Toyota Motor Corporation, 1200 Mishuku, Susono, Shizuoka 410-1193 (Japan)
2016-05-15
Size-selected clusters can be deposited on the surface using size-selected cluster ion beams. However, because of the cross-sectional intensity distribution of the ion beam, it is difficult to define the coverage of the deposited clusters. The aggregation probability of the cluster depends on coverage, whereas cluster size on the surface depends on the position, despite the size-selected clusters are deposited. It is crucial, therefore, to deposit clusters uniformly on the surface. In this study, size-selected clusters were deposited uniformly on surfaces by scanning the cluster ions in the form of Lissajous pattern. Two sets of deflector electrodes set in orthogonal directions were placed in front of the sample surface. Triangular waves were applied to the electrodes with an irrational frequency ratio to ensure that the ion trajectory filled the sample surface. The advantages of this method are simplicity and low cost of setup compared with raster scanning method. The authors further investigated CO adsorption on size-selected Pt{sub n} (n = 7, 15, 20) clusters uniformly deposited on the Al{sub 2}O{sub 3}/NiAl(110) surface and demonstrated the importance of uniform deposition.
Effect of scandia doping method on the emission uniformity of scandate cathode with Sc2O3–W matrix
International Nuclear Information System (INIS)
Wang, Jinshu; Lai, Chen; Liu, Wei; Yang, Fan; Zhang, Xizhu; Cui, Yuntao; Zhou, Meiling
2013-01-01
Graphical abstract: Emission uniformity of the cathodes prepared by mechanical mixing (a) and spray drying method (b). - Highlights: • The emission uniformity of scandate cathodes has been quantitively obtained. • The nanoparticles on the cathode surface lead to the electric field enhancement. • The cathode prepared by spray drying method exhibits good emission uniformity. - Abstract: Scandia doped tungsten matrix dispenser cathodes were manufactured using scandia doped tungsten powder prepared by mechanical mixing, liquid–solid doping and a spray drying method. It is found the macrostructure of the cathode depended on the powder preparation method. The cathode prepared using the powder prepared by spray drying method had a homogenous and porous matrix characterized with grains with a diameter of less than 1 μm and with many nanoparticles distributing uniformly around these grains. The cathode with submicron structure and uniform distribution of scandia exhibited good emission uniformity. The emission uniformity ΔJ/J of the cathode prepared by spray drying method was 0.17, about 6 times lower than that of the cathode prepared by mechanical mixing method. The calculation results showed that the nanoparticles led to electric field enhancement. A Ba–Sc–O multilayer on the cathode surface and nanoparticles distributing mainly on W grains contributed to the emission property of the cathode
Uniform magnetic targeting of magnetic particles attracted by a new ferromagnetic biological patch.
Pei, Ning; Cai, Lanlan; Yang, Kai; Ma, Jiaqi; Gong, Yongyong; Wang, Qixin; Huang, Zheyong
2018-02-01
A new non-toxic ferromagnetic biological patch (MBP) was designed in this paper. The MBP consisted of two external layers that were made of transparent silicone, and an internal layer that was made of a mixture of pure iron powder and silicon rubber. Finite-element analysis showed that the local inhomogeneous magnetic field (MF) around the MBP was generated when MBP was placed in a uniform MF. The local MF near the MBP varied with the uniform MF and shape of the MBP. Therefore, not only could the accumulation of paramagnetic particles be adjusted by controlling the strength of the uniform MF, but also the distribution of the paramagnetic particles could be improved with the different shape of the MBP. The relationship of the accumulation of paramagnetic particles or cells, magnetic flux density, and fluid velocity were studied through in vitro experiments and theoretical considerations. The accumulation of paramagnetic particles first increased with increment in the magnetic flux density of the uniform MF. But when the magnetic flux density of the uniform MF exceeded a specific value, the magnetic flux density of the MBP reached saturation, causing the accumulation of paramagnetic particles to fall. In addition, the adsorption morphology of magnetic particles or cells could be improved and the uniform distribution of magnetic particles could be achieved by changing the shape of the MBP. Also, MBP may be used as a new implant to attract magnetic drug carrier particles in magnetic drug targeting. Bioelectromagnetics. 39:98-107, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
International Nuclear Information System (INIS)
Zavgorodni, S.F.; Beckham, W.A.; Roos, D.E.
1996-01-01
The planning problems presented by abutting electron fields are well recognised. Junctioning electron fields with large hinge angle compounds the problems because of the creation of closely situated 'hot' and 'cold' spots. The technique involving a compensated superficial x-ray (SXR) field to treat the junction region between electron fields was developed and used in a particular clinical case (treatment of a squamous cell carcinoma of the forehead/scalp). The SXR beam parameters were chosen and the compensator was designed to make the SXR field complementary to the electron fields. Application of a compensated SXR field eliminated 'cold' spots in the junction region and minimised 'hot' spots to (110%). In the clinical case discusses the 'hot' spots due to the SXR field would not appear because of increased attenuation of the soft x-rays in bone. The technique proposed produces uniform dose distribution up to 3 cm deep and can be considered as an additional tool for dealing with electron fields junctioning problems. (author)
Directory of Open Access Journals (Sweden)
Christos F. Markides
2017-04-01
Full Text Available A recently introduced solution for the stress- and displacement-fields, developed in a multi-layered circular ring, composed of a finite number of linearly elastic concentric layers, subjected to a parabolic distribution of ra-dial stresses, is here extended to encompass a more general loading scheme, closer to actual conditions. The loading scheme includes, besides the para¬-bolic radial stresses, a combination of uniform pressures acting along the outer- and inner- most boundaries of the layered ring. The analytic solution of the problem is achieved by adopting Savin’s pioneering approach for an infinite plate with a hole strengthened by rings. Taking advantage of the results provided by the ana¬lytic solution, a numerical model, simulating the configuration of a three-layered ring (quite commonly encountered in practic¬al applications is validated. The numerical model is then used for a parametric analysis enlightening some crucial aspects of the overall response of the ring.
LED Uniform Illumination Using Double Linear Fresnel Lenses for Energy Saving
Directory of Open Access Journals (Sweden)
Ngoc Hai Vu
2017-12-01
Full Text Available We present a linear Fresnel lens design for light-emitting diode (LED uniform illumination applications. The LED source is an array of LEDs. An array of collimating lens is applied to collimate output from the LED array. Two linear Fresnel lenses are used to redistribute the collimated beam along two dimensions in the illumination area. Collimating lens and linear Fresnel lens surfaces are calculated by geometrical optics and nonimaging optics. The collimated beam output from the collimating lens array is divided into many fragments. Each fragment is refracted by a segment of Fresnel lens and distributed over the illumination area, so that the total beam can be distributed to the illumination target uniformly. The simulation results show that this design has a compact structure, high optical efficiency of 82% and good uniformity of 76.9%. Some consideration of the energy savings and optical performance are discussed by comparison with other typical light sources. The results show that our proposed LED lighting system can reduce energy consumption five-times in comparison to using a conventional fluorescent lamp. Our research is a strong candidate for low cost, energy savings for indoor and outdoor lighting applications.
You, Shihu; Xu, Yun; Wu, Zhangwen; Hou, Qing; Guo, Chengjun
2014-12-01
In the present work, Monte Carlo simulations were employed to study the characteristics of the dose distribution of high energy electron beam in the presence of uniform transverse magnetic field. The simulations carried out the transport processes of the 30 MeV electron beam in the homogeneous water phantom with different magnetic field. It was found that the dose distribution of the 30 MeV electron beam had changed significantly because of the magnetic field. The result showed that the range of the electron beam was decreased obviously and it formed a very high dose peak at the end of the range, and the ratio of maximum dose to the dose of the surface was greatly increased. The results of this study demonstrated that we could change the depth dose distribution of electron beam which is analogous to the heavy ion by modulating the energy of the electron and magnetic field. It means that using magnetic fields in conjunction with electron radiation therapy has great application prospect, but it also has brought new challenges for the research of dose algorithm.
Wu, Ping; Sun, Jun; Teng, Yan
2017-12-01
The emission uniformity of explosive emission cathodes is important to the operation of high power microwave generators. Although this concept seems to be widely accepted, the concrete influence of cathode emission uniformity on microwave generation has not been researched in detail and many conclusions on this matter are ambiguous due to the lack of solid evidence. This paper makes an effort to research this issue with particle-in-cell simulations about an X-band relativistic backward wave oscillator. To keep the diode impedance unchanged, an emission model in which each emission cell is artificially assigned a specific current density is adopted. The emission non-uniformity is simulated in three ways: spaced emission, large-area no-emission, and local enhanced emission. The simulation results uncover three phenomena: first, no significant influence is found for the cathode emission uniformity on the microwave starting time as long as no obvious mode competition is excited by emission non-uniformity; second, bad emission uniformity may bring about reduction of microwave power, but this may not happen when the emission non-uniformity is just localized to a few discrete strong emission points; third, under specific circumstances, the emission non-uniformity may lead to the excitation of mode competition, which can significantly delay the starting time and lower the microwave power.
Auction design for the allocation of carbon emission allowances: uniform or discriminatory price?
DEFF Research Database (Denmark)
Cong, Ronggang; wei, yi-ming
2010-01-01
Only four states used auction in Phase Ⅰ (2005-2007) of the European Union Emission Trading System, of which four used a uniform-price sealed auction format. Here we discuss whether the auction should adopt a uniform-price or discriminatory-price format using an agent-based carbon allowances...... auction model established for the purpose. The main conclusions are as follows: (1) when carbon allowances are relatively scarce, the government should use a discriminatory-price auction; when carbon allowances are relatively abundant, the government should use a uniform-price auction. (2) Uncertainty......) The uniform-price auction is relatively insensitive to market structure. However, a monopoly market is more likely to develop under the discriminatory-price auction format. The results of the model have some policy implications for designing carbon market mechanisms in the future....
Coghetto Roland
2016-01-01
In this article, using mostly Pervin [9], Kunzi [6], [8], [7], Williams [11] and Bourbaki [3] works, we formalize in Mizar [2] the notions of quasiuniform space, semi-uniform space and locally uniform space.
Filippov, Alexander E; Gorb, Stanislav N
2015-02-06
One of the important problems appearing in experimental realizations of artificial adhesives inspired by gecko foot hair is so-called clusterization. If an artificially produced structure is flexible enough to allow efficient contact with natural rough surfaces, after a few attachment-detachment cycles, the fibres of the structure tend to adhere one to another and form clusters. Normally, such clusters are much larger than original fibres and, because they are less flexible, form much worse adhesive contacts especially with the rough surfaces. Main problem here is that the forces responsible for the clusterization are the same intermolecular forces which attract fibres to fractal surface of the substrate. However, arrays of real gecko setae are much less susceptible to this problem. One of the possible reasons for this is that ends of the seta have more sophisticated non-uniformly distributed three-dimensional structure than that of existing artificial systems. In this paper, we simulated three-dimensional spatial geometry of non-uniformly distributed branches of nanofibres of the setal tip numerically, studied its attachment-detachment dynamics and discussed its advantages versus uniformly distributed geometry.
Energy Technology Data Exchange (ETDEWEB)
Pazirandeh, Ali [Islamic Azad Univ., Tehran (Iran, Islamic Republic of). Science and Research Branch; Hooshyar Mobaraki, Almas
2017-07-15
The safe operation of a reactor is based on feedback models. In this paper we attempted to discuss the influence of a non-uniform radial temperature distribution on the fuel rod temperature coefficient of reactivity. The paper demonstrates that the neutron properties of a reactor core is based on effective temperature of the fuel to obtain the correct fuel temperature feedback. The value of volume-averaged temperature being used in the calculations of neutron physics with feedbacks would result in underestimating the probable event. In the calculation it is necessary to use the effective temperature of the fuel in order to provide correct accounting of the fuel temperature feedback. Fuel temperature changes in different zones of the core and consequently reactivity coefficient change are an important parameter for analysis of transient conditions. The restricting factor that compensates the inserted reactivity is the temperature reactivity coefficient and effective delayed neutron fraction.
Directory of Open Access Journals (Sweden)
Coghetto Roland
2016-09-01
Full Text Available In this article, using mostly Pervin [9], Kunzi [6], [8], [7], Williams [11] and Bourbaki [3] works, we formalize in Mizar [2] the notions of quasiuniform space, semi-uniform space and locally uniform space.
White, Kerry A.
2000-01-01
In 1994, Long Beach (California) Unified School District began requiring uniforms in all elementary and middle schools. Now, half of all urban school systems and many suburban schools have uniform policies. Research on uniforms' effectiveness is mixed. Tightened dress codes may be just as effective and less litigious. (MLH)
High quality uniform YBCO film growth by the metalorganic deposition using trifluoroacetates
Energy Technology Data Exchange (ETDEWEB)
Wang, S.S., E-mail: wangssh@tsinghua.edu.cn [Key Laboratory of Micro-nano Measurement, Manipulation and Physics (Beihang University), Ministry of Education, Beijing 100191 (China); Beijing Dingchen Superconducting Technology Co., Ltd., Beijing 100084 (China); Zhang, Z.L. [Key Laboratory of Micro-nano Measurement, Manipulation and Physics (Beihang University), Ministry of Education, Beijing 100191 (China); Wang, L. [Applied superconductivity research center, Department of Physics, Tsinghua University, Beijing 100084 (China); Gao, L.K.; Liu, J. [Beijing Dingchen Superconducting Technology Co., Ltd., Beijing 100084 (China)
2017-03-15
Highlights: • High quality double-sided YBCO films are fabricated on LaAlO3 substrates by TFA-MOD method with diameters up to 2 in. • Large area YBCO films were very uniform in microstructure and thickness distribution, an average inductive Jc in excess of 6 MA/cm{sup 2} and low R{sub s} (10 GHz) of 0.3 mΩ at 77 K were obtained. • It will greatly promoted the research and applications of large-area YBCO films by chemical solution method. - Abstract: A need exists for the large-area superconducting YBa{sub 2}Cu{sub 3}O{sub 7-x} (YBCO) films with high critical current density for microwave communication and/or electric power applications. Trifluoroacetic metalorganic (TFA-MOD) method is a promising low cost technique for large-scale production of YBCO films, because it does not need high vacuum device and is easily applicable to substrates of various shape and size. In this paper, double-sided YBCO films with maximum 2 in diameter were prepared on LaAlO{sub 3} substrates by TFA-MOD method. Inductive critical current densitiy J{sub c}, microwave surface resistance R{sub s}, as well as the microstructure were characterized. A newly homemade furnace system was used to epitaxially grown YBCO films, which can improve the uniformity of YBCO film significantly by gas supply and temperature distribution proper design. Results showed that the large area YBCO films were very uniform in microstructure and thickness distribution, an average inductive J{sub c} in excess of 6 MA/cm{sup 2} with uniform distribution, and low R{sub s} (10 GHz) below 0.3 mΩ at 77 K were obtained. Andthe film filter may be prepared to work at temperatures lower than 74 K. These results are very close to the highest value of YBCO films made by conventional vacuum method, so we show a very promising route for large-scale production of high quality large-area YBCO superconducting films at a lower cost.
International Nuclear Information System (INIS)
Hurd, E.N.; Bitten, E.J.
1985-03-01
Fourteen tasks were identified by UNC Nuclear Industries for evaluating the life expectancy of N Reactor structures, systems and components in the Balance of Plant portion of the Production Assurance Program. A Westinghouse Hanford Company (WHC) evaluation team was assigned to each of these fourteen tasks. A uniform set of criteria was used by all teams in evaluating the problems that may be encountered during the extended plant operating lifetime. The overall conclusion is that extended life to those Balance of Plant components and systems studied can be achieved. Problems with the potential for compromising that conclusion are identified, and feasible solutions are provided
Passive containment cooling water distribution device
Conway, Lawrence E.; Fanto, Susan V.
1994-01-01
A passive containment cooling system for a nuclear reactor containment vessel. Disclosed is a cooling water distribution system for introducing cooling water by gravity uniformly over the outer surface of a steel containment vessel using a series of radial guide elements and cascading weir boxes to collect and then distribute the cooling water into a series of distribution areas through a plurality of cascading weirs. The cooling water is then uniformly distributed over the curved surface by a plurality of weir notches in the face plate of the weir box.
Directory of Open Access Journals (Sweden)
Xin Su
2015-01-01
Full Text Available There have been many studies regarding antenna polarization; however, there have been few publications on the analysis of the channel capacity for polarized antenna systems using the beamforming technique. According to Chung et al., the channel capacity is determined by the density of scatterers and the transmission power, which is obtained based on the assumption that scatterers are uniformly distributed on a 3D spherical scattering model. However, it contradicts the practical scenario, where scatterers may not be uniformly distributed under outdoor environment, and lacks the consideration of fading channel gain. In this study, we derive the channel capacity of polarized uniform linear array (PULA systems using the beamforming technique in a practical scattering environment. The results show that, for PULA systems, the channel capacity, which is boosted by beamforming diversity, can be determined using the channel gain, beam radiation pattern, and beamforming diversity order (BDO, where the BDO is dependent on the antenna characteristics and array configurations.
Non-uniformity measurements of PbWO4 crystals
International Nuclear Information System (INIS)
Depasse, P.; Ernenwein, J.P.; Ille, B.; Martin, F.; Rosset, C.; Zach, F.
1998-11-01
Two independent methods have been used to measure the longitudinal non-uniformity scintillation response of 3 different (23-cm long) PbWO 4 crystals. The first one is the classical 60 Co source method. The source is collimated along the crystal, each 1,5-cm, and the scintillation signal is measured with a photomultiplier (a hybrid photomultiplier in our case). The second one is the use of cosmic particles (Minimum Ionizing Particles). A cosmic bench allows reconstructing the track of the MIP's and thus the energy deposit with the help of a full GEANT simulation of the setup. Variations of E along the crystal artificially cut in 1,5-cm divisions, leads to determine the non-uniformity. The conclusion is that both methods agree quite well. Furthermore, a good estimation of crystal light yield can be obtained. (author)
On natural frequencies of non-uniform beams modulated by finite periodic cells
International Nuclear Information System (INIS)
Xu, Yanlong; Zhou, Xiaoling; Wang, Wei; Wang, Longqi; Peng, Fujun; Li, Bin
2016-01-01
It is well known that an infinite periodic beam can support flexural wave band gaps. However, in real applications, the number of the periodic cells is always limited. If a uniform beam is replaced by a non-uniform beam with finite periodicity, the vibration changes are vital by mysterious. This paper employs the transfer matrix method (TMM) to study the natural frequencies of the non-uniform beams with modulation by finite periodic cells. The effects of the amounts, cross section ratios, and arrangement forms of the periodic cells on the natural frequencies are explored. The relationship between the natural frequencies of the non-uniform beams with finite periodicity and the band gap boundaries of the corresponding infinite periodic beam is also investigated. Numerical results and conclusions obtained here are favorable for designing beams with good vibration control ability. - Highlights: • The transfer matrix method to study the natural frequencies of the finite periodic non-uniform beams is derived. • The transfer matrix method to study the band gaps of the infinite periodic non-uniform beams is derived. • The effects of the periodic cells on the natural frequencies are explored. • The relationships of the natural frequencies and band gap boundaries are investigated.
On natural frequencies of non-uniform beams modulated by finite periodic cells
Energy Technology Data Exchange (ETDEWEB)
Xu, Yanlong, E-mail: xuyanlong@nwpu.edu.cn [School of Aeronautics, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Zhou, Xiaoling [Shanghai Institute of Aerospace System Engineering, Shanghai 201109 (China); Wang, Wei [School of Aeronautics, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Wang, Longqi [School of Civil & Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Peng, Fujun [Shanghai Institute of Aerospace System Engineering, Shanghai 201109 (China); Li, Bin [School of Aeronautics, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China)
2016-09-23
It is well known that an infinite periodic beam can support flexural wave band gaps. However, in real applications, the number of the periodic cells is always limited. If a uniform beam is replaced by a non-uniform beam with finite periodicity, the vibration changes are vital by mysterious. This paper employs the transfer matrix method (TMM) to study the natural frequencies of the non-uniform beams with modulation by finite periodic cells. The effects of the amounts, cross section ratios, and arrangement forms of the periodic cells on the natural frequencies are explored. The relationship between the natural frequencies of the non-uniform beams with finite periodicity and the band gap boundaries of the corresponding infinite periodic beam is also investigated. Numerical results and conclusions obtained here are favorable for designing beams with good vibration control ability. - Highlights: • The transfer matrix method to study the natural frequencies of the finite periodic non-uniform beams is derived. • The transfer matrix method to study the band gaps of the infinite periodic non-uniform beams is derived. • The effects of the periodic cells on the natural frequencies are explored. • The relationships of the natural frequencies and band gap boundaries are investigated.
Dynamics beyond uniform hyperbolicity a global geometric and probabilistic perspective
Bonatti, Christian; Viana, Marcelo
2005-01-01
The notion of uniform hyperbolicity, introduced by Steve Smale in the early sixties, unified important developments and led to a remarkably successful theory for a large class of systems: uniformly hyperbolic systems often exhibit complicated evolution which, nevertheless, is now rather well understood, both geometrically and statistically.Another revolution has been taking place in the last couple of decades, as one tries to build a global theory for "most" dynamical systems, recovering as much as possible of the conclusions of the uniformly hyperbolic case, in great generality. This book aims to put such recent developments in a unified perspective, and to point out open problems and likely directions for further progress. It is aimed at researchers, both young and senior, willing to get a quick, yet broad, view of this part of dynamics. Main ideas, methods, and results are discussed, at variable degrees of depth, with references to the original works for details and complementary information.
Improvement of Pulping Uniformity by Measurement of Single Fiber Kappa Number
Energy Technology Data Exchange (ETDEWEB)
Richard R. Gustafson; James B. Callis
2001-11-20
A method to measure the kappa of single fibers by staining with a fluorescent dye, Acridine Orange (AO), has been developed. This method is now applied to develop and automated flow-through instrument that permits routine kappa analysis on thousands of images of AO stained fibers to give the fiber kappa number distribution of a pulp sample in a few minutes. The design and operation of the instrument are similar to that of a flow cytometer but with the addition of extensive fiber imaging capability. Fluorescence measurements in the flow-through instrument are found to be consistent with those made with fluorescence microscope provided the signal processing in the flow-thou instrument is handled propertly. The kappa distributions of pulps that were analyzed by means of a density gradient column are compared to those measured with the flow-through instrument with good results. The kappa distributions of various laboratory pulps and commercial pulps have been measured. It has been found that all pulps are non-uniform but that ommercial pulps generally have broader kappa distributions thatn their laboratory counterparts. The effects of different pulping methods and chip pretreatments on pulp uniformity are discussed in the report. Finally, the application of flow-through fluorescence technology to other single fiber measurements are presented.
Liquid jets injected into non-uniform crossflow
Tambe, Samir
An experimental study has been conducted with liquid jets injected transversely into a crossflow to study the effect of non-uniformities in the crossflow velocity distribution to the jet behavior. Two different non-uniform crossflows were created during this work, a shear-laden crossflow and a swirling crossflow. The shear-laden crossflow was generated by merging two independent, co-directional, parallel airstreams creating a shear mixing layer at the interface between them. The crossflow exhibited a quasi-linear velocity gradient across the height of the test chamber. By varying the velocities of the two airstreams, the sense and the slope of the crossflow velocity gradient could be changed. Particle Image Velocimetry (PIV) studies were conducted to characterize the crossflow. The parameter, UR, is defined as the ratio of the velocities of the two streams and governs the velocity gradient. A positive velocity gradient was observed for UR > 1 and a negative velocity gradient for UR Phase Doppler Particle Anemometry (PDPA) studies were conducted to study the penetration and atomization of 0.5 mm diameter water jets injected into this crossflow. The crossflow velocity gradient was observed to have a significant effect on jet penetration as well as the post breakup spray. For high UR (> 1), jet penetration increased and the Sauter Mean Diameter (SMD) distribution became more uniform. For low UR (Doppler Velocimetry (LDV) was used to study the crossflow velocities. The axial (Ux) and the tangential (Utheta) components of the crossflow velocity were observed to decrease with increasing radial distance away from the centerbody. The flow angle of the crossflow was smaller than the vane exit angle, with the difference increasing with the vane exit angle. Water jets were injected from a 0.5 mm diameter orifice located on a cylindrical centerbody. Multi-plane PIV measurements were conducted to study the penetration and droplet velocity distribution of the jets. The jets were
Energy Technology Data Exchange (ETDEWEB)
Wang, Jinshu, E-mail: wangjsh@bjut.edu.cn; Lai, Chen; Liu, Wei; Yang, Fan; Zhang, Xizhu; Cui, Yuntao; Zhou, Meiling
2013-09-01
Graphical abstract: Emission uniformity of the cathodes prepared by mechanical mixing (a) and spray drying method (b). - Highlights: • The emission uniformity of scandate cathodes has been quantitively obtained. • The nanoparticles on the cathode surface lead to the electric field enhancement. • The cathode prepared by spray drying method exhibits good emission uniformity. - Abstract: Scandia doped tungsten matrix dispenser cathodes were manufactured using scandia doped tungsten powder prepared by mechanical mixing, liquid–solid doping and a spray drying method. It is found the macrostructure of the cathode depended on the powder preparation method. The cathode prepared using the powder prepared by spray drying method had a homogenous and porous matrix characterized with grains with a diameter of less than 1 μm and with many nanoparticles distributing uniformly around these grains. The cathode with submicron structure and uniform distribution of scandia exhibited good emission uniformity. The emission uniformity ΔJ/J of the cathode prepared by spray drying method was 0.17, about 6 times lower than that of the cathode prepared by mechanical mixing method. The calculation results showed that the nanoparticles led to electric field enhancement. A Ba–Sc–O multilayer on the cathode surface and nanoparticles distributing mainly on W grains contributed to the emission property of the cathode.
Institute of Scientific and Technical Information of China (English)
Linda
2008-01-01
The uniforms for Beijing Olympics’ workers, technical staff and volunteers have been unveiled to mark the 200-day countdown to the Games. The uniforms feature the key element of the clouds of promise and will be in three colors:red for Beijing Olympic Games Committee staff, blue
Highly ordered uniform single-crystal Bi nanowires: fabrication and characterization
International Nuclear Information System (INIS)
Bisrat, Y; Luo, Z P; Davis, D; Lagoudas, D
2007-01-01
A mechanical pressure injection technique has been used to fabricate uniform bismuth (Bi) nanowires in the pores of an anodic aluminum oxide (AAO) template. The AAO template was prepared from general purity aluminum by a two-step anodization followed by heat treatment to achieve highly ordered nanochannels. The nanowires were then fabricated by an injection technique whereby the molten Bi was injected into the AAO template using a hydraulic pressure method. The Bi nanowires prepared by this method were found to be dense and continuous with uniform diameter throughout the length. Electron diffraction experiments using the transmission electron microscope on cross-sectional and free-standing longitudinal Bi nanowires showed that the majority of the individual nanowires were single crystalline, with preferred orientation of growth along the [011] zone axis of the pseudo-cubic structure. The work presented here provides an inexpensive and effective way of fabricating highly ordered single-crystalline Bi nanowires, with uniform size distributions
International Nuclear Information System (INIS)
Wadayama, Y.; Koizumi, N.; Takahashi, Y.; Matsui, K.; Tsuji, H.; Shimamoto, S.
1996-01-01
30kA-NbTi Demo Poloidal Coil (DPC-U) exhibited instability such as the conductor quenches at 40% of the rated current which is still much smaller than the expected conductor critical current. It was found that this instability was caused by the non-uniform current distribution in the DPC-U conductor whose strands were insulated from each other. To investigate the instability of the DPC-U conductor, a stability experiment of a subsize conductor consisting of 27 strands was performed and the effect of the current imbalance on the stability was investigated. The current imbalance was forcibly established in the conductor using two current sources in this experiment. The experimental results indicate that the stability margin decreases as the current imbalance becomes larger and that the stability margin of the conductor is governed by the stability of the strand with the highest current in the conductor. Also, it is confirmed from the experimental results that the instability of DPC-U has to be attributed to the current imbalance in the conductor
Analysis of single blow effectiveness in non-uniform parallel plate regenerators
DEFF Research Database (Denmark)
Jensen, Jesper Buch; Bahl, Christian Robert Haffenden; Engelbrecht, Kurt
2011-01-01
Non-uniform distributions of plate spacings in parallel plate regenerators have been found to induce loss of performance. In this paper, it has been investigated how variations of three geometric parameters (the aspect ratio, the porosity, and the standard deviation of the plate spacing) affects...
A poloidal non-uniformity of the collisionless parallel current in a tokamak plasma
Energy Technology Data Exchange (ETDEWEB)
Romannikov, A.; Fenzi-Bonizec, C
2005-07-01
The collisionless distortion of the ion (electron) distribution function at certain points on a magnetic surface is studied in the framework of a simple model of a large aspect ratio tokamak plasma. The flow velocity driven by this distortion is calculated. The possibility of an additional non-uniform collisionless parallel current density on a magnetic surface, other than the known neo-classical non-uniformity is shown. The difference between the parallel current density on the low and high field side of a magnetic surface is close to the neoclassical bootstrap current density. The first Tore-Supra experimental test indicates the possibility of the poloidal non-uniformity of the parallel current density. (authors)
Directory of Open Access Journals (Sweden)
Zhi Liu
Full Text Available DNA microarray analysis is an effective method to detect unintended effects by detecting differentially expressed genes (DEG in safety assessment of genetically modified (GM crops. With the aim to reveal the distribution of DEG of GM crops under different conditions, we performed DNA microarray analysis using transgenic rice Huahui 1 (HH1 and its non-transgenic parent Minghui 63 (MH63 at different developmental stages and environmental conditions. Considerable DEG were selected in each group of HH1 under different conditions. For each group of HH1, the number of DEG was different; however, considerable common DEG were shared between different groups of HH1. These findings suggested that both DEG and common DEG were adequate for investigation of unintended effects. Furthermore, a number of significantly changed pathways were found in all groups of HH1, indicating genetic modification caused everlasting changes to plants. To our knowledge, our study for the first time provided the non-uniformly distributed pattern for DEG of GM crops at different developmental stages and environments. Our result also suggested that DEG selected in GM plants at specific developmental stage and environment could act as useful clues for further evaluation of unintended effects of GM plants.
Large-scale syntheses of uniform ZnO nanorods and ethanol gas sensors application
International Nuclear Information System (INIS)
Chen Jin; Li Jin; Li Jiahui; Xiao Guoqing; Yang Xiaofeng
2011-01-01
Research highlights: → The uniform ZnO nanorods could be synthesized by a low temperature, solution-based method. → The results showed that the sample had uniform rod-like morphology with a narrow size distribution and highly crystallinity. → Room-temperature photoluminescence spectra of these nanorods show an exciton emission around 382 nm and a weak deep level emission, indicating the nanorods have high quality. → The sensor exhibited high sensitivity and fast response to ethanol gas at a work temperature of 400 deg. C. - Abstract: Uniform ZnO nanorods with a gram scale were prepared by a low temperature and solution-based method. The samples are characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and photoluminescence (PL). The results showed that the sample had uniform rod-like morphology with a narrow size distribution and highly crystallinity. Room-temperature PL spectra of these nanorods show an exciton emission around 382 nm and a negligible deep level emission, indicating the nanorods have high quality. The gas-sensing properties of the materials have been investigated. The results indicate that the as-prepared nanorods show much better sensitivity and stability. The n-type semiconductor gas sensor exhibited high sensitivity and fast response to ethanol gas at a work temperature of 400 deg. C. ZnO nanorods are excellent potential candidates for highly sensitive gas sensors and ultraviolet laser.
Design and testing of a uniformly solar energy TIR-R concentration lenses for HCPV systems.
Shen, S C; Chang, S J; Yeh, C Y; Teng, P C
2013-11-04
In this paper, total internal reflection-refraction (TIR-R) concentration (U-TIR-R-C) lens module were designed for uniformity using the energy configuration method to eliminate hot spots on the surface of solar cell and increase conversion efficiency. The design of most current solar concentrators emphasizes the high-power concentration of solar energy, however neglects the conversion inefficiency resulting from hot spots generated by uneven distributions of solar energy concentrated on solar cells. The energy configuration method proposed in this study employs the concept of ray tracing to uniformly distribute solar energy to solar cells through a U-TIR-R-C lens module. The U-TIR-R-C lens module adopted in this study possessed a 76-mm diameter, a 41-mm thickness, concentration ratio of 1134 Suns, 82.6% optical efficiency, and 94.7% uniformity. The experiments demonstrated that the U-TIR-R-C lens module reduced the core temperature of the solar cell from 108 °C to 69 °C and the overall temperature difference from 45 °C to 10 °C, and effectively relative increased the conversion efficiency by approximately 3.8%. Therefore, the U-TIR-R-C lens module designed can effectively concentrate a large area of sunlight onto a small solar cell, and the concentrated solar energy can be evenly distributed in the solar cell to achieve uniform irradiance and effectively eliminate hot spots.
Voltage uniformity study in large-area reactors for RF plasma deposition
Energy Technology Data Exchange (ETDEWEB)
Sansonnens, L.; Pletzer, A.; Magni, D.; Howling, A.A.; Hollenstein, C. [Ecole Polytechnique Federale, Lausanne (Switzerland). Centre de Recherche en Physique des Plasma (CRPP); Schmitt, J.P.M. [Balzers Process Systems, Palaiseau (France)
1996-09-01
Non-uniform voltage distribution across the electrode area results in inhomogeneous thin-film RF plasma deposition in large area reactors. In this work, a two-dimensional analytic model for the calculation of the voltage distribution across the electrode area is presented. The results of this model are in good agreement with measurements performed without plasma at 13.56 MHz and 70 MHz in a large area reactor. The principal voltage inhomogeneities are caused by logarithmic singularities in the vicinity of RF connections and not by standing waves. These singularities are only described by a two-dimensional model and cannot be intuitively predicted by analogy to a one-dimensional case. Plasma light emission measurements and thickness homogeneity studies of a-Si:H films show that the plasma reproduces these voltage inhomogeneities. Improvement of the voltage uniformity is investigated by changing the number and position of the RF connections. (author) 13 figs., 20 refs.
Liel, Y
1999-01-01
Relatively little is known about the cytological characteristics of hyperfunctioning (hot) thyroid nodules. Concern has been expressed that fine-needle aspiration (FNA) identifies hot nodules as follicular tumors or indeterminate, and as a consequence patients could be unnecessarily referred for surgery. Between 1979 and 1996, thyroid FNA was performed on 829 patients. Result of thyroid scan was available in 326; 69 (21%) patients had hot, and 257 (79%) had warm or cold thyroid nodules. Nodules in each of these major groups were divided into 2 subgroups: clinically solitary nodules and dominant nodules in multinodular goiters (MNG). The frequencies of adequate versus inadequate FNA samples, and of conclusive versus indeterminate FNA results were determined separately for each of the groups and subgroups. In addition, patients with hot nodules and overt hyperthyroidism were identified and evaluated separately. Bivariate analyses were performed for the frequency of adequate versus inadequate smears and conclusive versus indeterminate results between hot, toxic, and cold-warm nodules, and between solitary nodules and MNG. The frequency of adequate aspirations and conclusive results in the various groups and subgroups was found to be statistically indistinguishable. In conclusion, the yield of adequate samples and the rate of conclusive results of FNA in thyroid nodules is similar, irrespective of the functional state or of goiter presentation. Hot thyroid nodules do not seem to produce an increase in the rate of inadequate or indeterminate FNA results, and therefore, do not affect the overall performance of thyroid FNA.
Widyawan, A.; Pasaribu, U. S.; Henintyas, Permana, D.
2015-12-01
Nowadays some firms, including insurer firms, think that customer-centric services are better than product-centric ones in terms of marketing. Insurance firms will try to attract as many new customer as possible while maintaining existing customer. This causes the Customer Lifetime Value (CLV) becomes a very important thing. CLV are able to put customer into different segments and calculate the present value of a firm's relationship with its customer. Insurance customer will depend on the last service he or she can get. So if the service is bad now, then customer will not renew his contract though the service is very good at an erlier time. Because of this situation one suitable mathematical model for modeling customer's relationships and calculating their lifetime value is Markov Chain. In addition, the advantages of using Markov Chain Modeling is its high degree of flexibility. In 2000, Pfeifer and Carraway states that Markov Chain Modeling can be used for customer retention situation. In this situation, Markov Chain Modeling requires only two states, which are present customer and former ones. This paper calculates customer lifetime value in an insurance firm with two distinctive interest rates; the constant interest rate and uniform distribution of interest rates. The result shows that loyal customer and the customer who increase their contract value have the highest CLV.
Indian Academy of Sciences (India)
First page Back Continue Last page Overview Graphics. Conclusion. Problems of an Under-developed Economy. Geographical Location. Terrain. Change in attitude of mainstream India required. Using Technology to overcome problems.
Additive non-uniform random sampling in superimposed fiber Bragg grating strain gauge
Ma, Y. C.; Liu, H. Y.; Yan, S. B.; Yang, Y. H.; Yang, M. W.; Li, J. M.; Tang, J.
2013-05-01
This paper demonstrates an additive non-uniform random sampling and interrogation method for dynamic and/or static strain gauge using a reflection spectrum from two superimposed fiber Bragg gratings (FBGs). The superimposed FBGs are designed to generate non-equidistant space of a sensing pulse train in the time domain during dynamic strain gauge. By combining centroid finding with smooth filtering methods, both the interrogation speed and accuracy are improved. A 1.9 kHz dynamic strain is measured by generating an additive non-uniform randomly distributed 2 kHz optical sensing pulse train from a mean 500 Hz triangular periodically changing scanning frequency.
Nazir, Habiba; Lv, Piping; Wang, Lianyan; Lian, Guoping; Zhu, Shiping; Ma, Guanghui
2011-12-01
Emulsions are commonly used in foods, pharmaceuticals and home-personal-care products. For emulsion based products, it is highly desirable to control the droplet size distribution to improve storage stability, appearance and in-use property. We report preparation of uniform-sized silicone oil microemulsions with different droplets diameters (1.4-40.0 μm) using SPG membrane emulsification technique. These microemulsions were then added into model shampoos and conditioners to investigate the effects of size, uniformity, and storage stability on silicone oil deposition on hair surface. We observed much improved storage stability of uniform-sized microemulsions when the droplets diameter was ≤22.7 μm. The uniform-sized microemulsion of 40.0 μm was less stable but still more stable than non-uniform sized microemulsions prepared by conventional homogenizer. The results clearly indicated that uniform-sized droplets enhanced the deposition of silicone oil on hair and deposition increased with decreasing droplet size. Hair switches washed with small uniform-sized droplets had lower values of coefficient of friction compared with those washed with larger uniform and non-uniform droplets. Moreover the addition of alginate thickener in the shampoos and conditioners further enhanced the deposition of silicone oil on hair. The good correlation between silicone oil droplets stability, deposition on hair and resultant friction of hair support that droplet size and uniformity are important factors for controlling the stability and deposition property of emulsion based products such as shampoo and conditioner. Copyright © 2011 Elsevier Inc. All rights reserved.
Li, Wei; Yang, Zhen; Hu, Haifeng
2014-01-01
Graphical models have been widely applied in solving distributed inference problems in wireless networks. In this paper, we formulate the cooperative localization problem in a mobile network as an inference problem on a factor graph. Using a sequential schedule of message updates, a sequential uniformly reweighted sum-product algorithm (SURW-SPA) is developed for mobile localization problems. The proposed algorithm combines the distributed nature of belief propagation (BP) with the improved p...
Coral, W.; Rossi, C.; Curet, O. M.
2015-12-01
This paper presents a Differential Quadrature Element Method for free transverse vibration of a robotic fish based on a continuous and non-uniform flexible backbone with distributed masses (fish ribs). The proposed method is based on the theory of a Timoshenko cantilever beam. The effects of the masses (number, magnitude and position) on the value of natural frequencies are investigated. Governing equations, compatibility and boundary conditions are formulated according to the Differential Quadrature rules. The convergence, efficiency and accuracy are compared to other analytical solution proposed in the literature. Moreover, the proposed method has been validate against the physical prototype of a flexible fish backbone. The main advantages of this method, compared to the exact solutions available in the literature are twofold: first, smaller computational cost and second, it allows analysing the free vibration in beams whose section is an arbitrary function, which is normally difficult or even impossible with other analytical methods.
Energy Technology Data Exchange (ETDEWEB)
Jiang, Wei; Wang, Langping, E-mail: aplpwang@hit.edu.cn; Zhou, Guangxue; Wang, Xiaofeng
2017-02-01
Highlights: • The transmission process of electrons and irradiation uniformity was simulated. • Influence of the irradiation parameters on irradiation uniformity are discussed. • High irradiation uniformity can be obtained in a wide processing window. - Abstract: In order to study electron trajectories in an annular cathode high current pulsed electron beam (HCPEB) source based on carbon fiber bunches, the transmission process of electrons emitted from the annular cathode was simulated using a particle-in-cell model with Monte Carlo collisions (PIC-MCC). The simulation results show that the intense flow of the electrons emitted from the annular cathode are expanded during the transmission process, and the uniformity of the electron distribution is improved in the transportation process. The irradiation current decreases with the irradiation distance and the pressure, and increases with the negative voltage. In addition, when the irradiation distance and the cathode voltage are larger than 40 mm and −15 kV, respectively, a uniform irradiation current distribution along the circumference of the anode can be obtained. The simulation results show that good irradiation uniformity of circular components can be achieved by this annular cathode HCPEB source.
Hsu, Ya-Chu; Hung, Yu-Chen; Wang, Chiu-Yen
2017-09-15
High uniformity Au-catalyzed indium selenide (In 2 Se 3) nanowires are grown with the rapid thermal annealing (RTA) treatment via the vapor-liquid-solid (VLS) mechanism. The diameters of Au-catalyzed In 2 Se 3 nanowires could be controlled with varied thicknesses of Au films, and the uniformity of nanowires is improved via a fast pre-annealing rate, 100 °C/s. Comparing with the slower heating rate, 0.1 °C/s, the average diameters and distributions (standard deviation, SD) of In 2 Se 3 nanowires with and without the RTA process are 97.14 ± 22.95 nm (23.63%) and 119.06 ± 48.75 nm (40.95%), respectively. The in situ annealing TEM is used to study the effect of heating rate on the formation of Au nanoparticles from the as-deposited Au film. The results demonstrate that the average diameters and distributions of Au nanoparticles with and without the RTA process are 19.84 ± 5.96 nm (30.00%) and about 22.06 ± 9.00 nm (40.80%), respectively. It proves that the diameter size, distribution, and uniformity of Au-catalyzed In 2 Se 3 nanowires are reduced and improved via the RTA pre-treated. The systemic study could help to control the size distribution of other nanomaterials through tuning the annealing rate, temperatures of precursor, and growth substrate to control the size distribution of other nanomaterials. Graphical Abstract Rapid thermal annealing (RTA) process proved that it can uniform the size distribution of Au nanoparticles, and then it can be used to grow the high uniformity Au-catalyzed In 2 Se 3 nanowires via the vapor-liquid-solid (VLS) mechanism. Comparing with the general growth condition, the heating rate is slow, 0.1 °C/s, and the growth temperature is a relatively high growth temperature, > 650 °C. RTA pre-treated growth substrate can form smaller and uniform Au nanoparticles to react with the In 2 Se 3 vapor and produce the high uniformity In 2 Se 3 nanowires. The in situ annealing TEM is used to realize the effect of heating
Uniform competency-based local feature extraction for remote sensing images
Sedaghat, Amin; Mohammadi, Nazila
2018-01-01
Local feature detectors are widely used in many photogrammetry and remote sensing applications. The quantity and distribution of the local features play a critical role in the quality of the image matching process, particularly for multi-sensor high resolution remote sensing image registration. However, conventional local feature detectors cannot extract desirable matched features either in terms of the number of correct matches or the spatial and scale distribution in multi-sensor remote sensing images. To address this problem, this paper proposes a novel method for uniform and robust local feature extraction for remote sensing images, which is based on a novel competency criterion and scale and location distribution constraints. The proposed method, called uniform competency (UC) local feature extraction, can be easily applied to any local feature detector for various kinds of applications. The proposed competency criterion is based on a weighted ranking process using three quality measures, including robustness, spatial saliency and scale parameters, which is performed in a multi-layer gridding schema. For evaluation, five state-of-the-art local feature detector approaches, namely, scale-invariant feature transform (SIFT), speeded up robust features (SURF), scale-invariant feature operator (SFOP), maximally stable extremal region (MSER) and hessian-affine, are used. The proposed UC-based feature extraction algorithms were successfully applied to match various synthetic and real satellite image pairs, and the results demonstrate its capability to increase matching performance and to improve the spatial distribution. The code to carry out the UC feature extraction is available from href="https://www.researchgate.net/publication/317956777_UC-Feature_Extraction.
SYVAC3 parameter distribution package
Energy Technology Data Exchange (ETDEWEB)
Andres, T; Skeet, A
1995-01-01
SYVAC3 (Systems Variability Analysis Code, generation 3) is a computer program that implements a method called systems variability analysis to analyze the behaviour of a system in the presence of uncertainty. This method is based on simulating the system many times to determine the variation in behaviour it can exhibit. SYVAC3 specializes in systems representing the transport of contaminants, and has several features to simplify the modelling of such systems. It provides a general tool for estimating environmental impacts from the dispersal of contaminants. This report describes a software object type (a generalization of a data type) called Parameter Distribution. This object type is used in SYVAC3, and can also be used independently. Parameter Distribution has the following subtypes: beta distribution; binomial distribution; constant distribution; lognormal distribution; loguniform distribution; normal distribution; piecewise uniform distribution; Triangular distribution; and uniform distribution. Some of these distributions can be altered by correlating two parameter distribution objects. This report provides complete specifications for parameter distributions, and also explains how to use them. It should meet the needs of casual users, reviewers, and programmers who wish to add their own subtypes. (author). 30 refs., 75 tabs., 56 figs.
International Nuclear Information System (INIS)
Xia, Huanxiong; Xiang, Dong; Yang, Wang; Mou, Peng
2014-01-01
Low-temperature plasma technique is one of the critical techniques in IC manufacturing process, such as etching and thin-film deposition, and the uniformity greatly impacts the process quality, so the design for the plasma uniformity control is very important but difficult. It is hard to finely and flexibly regulate the spatial distribution of the plasma in the chamber via controlling the discharge parameters or modifying the structure in zero-dimensional space, and it just can adjust the overall level of the process factors. In the view of this problem, a segmented non-uniform dielectric module design solution is proposed for the regulation of the plasma profile in a CCP chamber. The solution achieves refined and flexible regulation of the plasma profile in the radial direction via configuring the relative permittivity and the width of each segment. In order to solve this design problem, a novel simulation-based auto-design approach is proposed, which can automatically design the positional sequence with multi independent variables to make the output target profile in the parameterized simulation model approximate the one that users preset. This approach employs an idea of quasi-closed-loop control system, and works in an iterative mode. It starts from initial values of the design variable sequences, and predicts better sequences via the feedback of the profile error between the output target profile and the expected one. It never stops until the profile error is narrowed in the preset tolerance
46 CFR 310.11 - Cadet uniforms.
2010-10-01
... for State, Territorial or Regional Maritime Academies and Colleges § 310.11 Cadet uniforms. Cadet uniforms shall be supplied at the school in accordance with the uniform regulations of the School. Those... 46 Shipping 8 2010-10-01 2010-10-01 false Cadet uniforms. 310.11 Section 310.11 Shipping MARITIME...
Directory of Open Access Journals (Sweden)
Juan Manuel García-Guendulain
2018-04-01
Full Text Available Flow maldistribution represents a problem of particular interest in the engineering field for several thermal systems. In flat plate solar collectors, the thermal efficiency strongly depends on the flow distribution through the riser tubes, where a uniform distribution causes a uniform temperature distribution and therefore a higher efficiency. In this work, a Computational Fluid Dynamics (CFD numerical analysis has been carried out using the commercial software FLUENT®, in order to determine the flow distribution, pressure drop and hence the thermal efficiency of a solar collector with distribution flow plates inside the manifolds. The obtained numerical solution for this type of thermal systems has been validated with experimental results available in literature for laminar and turbulent flow. Four distribution plate configurations were analyzed. Results show that using two distribution plates in each of both manifolds improves the flow uniformity up to 40% under the same operating conditions when distribution plates are not used. Besides, it is shown that there exists an increase in the overall pressure drop which is practically negligible for the tilt angles commonly employed in the installation of flat plate solar collectors in Mexico. The use of closed end distribution plates on the dividing and combining manifolds allows the thermal efficiency to become close to the ideal thermal efficiency which is obtained with a uniform flow distribution.
Shirley, Britt M.; Wooldridge, Barbara Ross; Camp, Kerri M.
2012-01-01
Jen Harrington is the owner and pastry chef of Sweet Conclusion, a bakery in Tampa, Florida. Most of Harrington's business comes from baking wedding cakes, but she has been attempting to attract customers to her retail bakery, where she sells cupcakes, pies, ice cream, and coffee. Nearly four years she opened Sweet Conclusion, the retail part of…
Should School Nurses Wear Uniforms?
Journal of School Health, 2001
2001-01-01
This 1958 paper questions whether school nurses should wear uniforms (specifically, white uniforms). It concludes that white uniforms are often associated with the treatment of ill people, and since many people have a fear reaction to them, they are not necessary and are even undesirable. Since school nurses are school staff members, they should…
Efficient SPECT scatter calculation in non-uniform media using correlated Monte Carlo simulation
International Nuclear Information System (INIS)
Beekman, F.J.
1999-01-01
Accurate simulation of scatter in projection data of single photon emission computed tomography (SPECT) is computationally extremely demanding for activity distribution in non-uniform dense media. This paper suggests how the computation time and memory requirements can be significantly reduced. First the scatter projection of a uniform dense object (P SDSE ) is calculated using a previously developed accurate and fast method which includes all orders of scatter (slab-derived scatter estimation), and then P SDSE is transformed towards the desired projection P which is based on the non-uniform object. The transform of P SDSE is based on two first-order Compton scatter Monte Carlo (MC) simulated projections. One is based on the uniform object (P u ) and the other on the object with non-uniformities (P ν ). P is estimated by P-tilde=P SDSE P ν /P u . A tremendous decrease in noise in P-tilde is achieved by tracking photon paths for P ν identical to those which were tracked for the calculation of P u and by using analytical rather than stochastic modelling of the collimator. The method was validated by comparing the results with standard MC-simulated scatter projections (P) of 99m Tc and 201 Tl point sources in a digital thorax phantom. After correction, excellent agreement was obtained between P-tilde and P. The total computation time required to calculate an accurate scatter projection of an extended distribution in a thorax phantom on a PC is a only few tens of seconds per projection, which makes the method attractive for application in accurate scatter correction in clinical SPECT. Furthermore, the method removes the need of excessive computer memory involved with previously proposed 3D model-based scatter correction methods. (author)
Energy Technology Data Exchange (ETDEWEB)
Cho, Hyuksu; Yi, Kunwoo; Choe, Yoonjae; Jang, Hocheol; Yune, Seokjeong; Park, Seongchan [KEPCO Engineering and Construction, Daejeon (Korea, Republic of)
2016-10-15
In this study, a computational analysis is performed to predict the deviation in the temperature distribution in the hot leg pipe according to the flow rate variation in RCS. In the hot leg pipes of Reactor Coolant System (RCS) of APR1400, four Resistance Temperature Detectors (RTDs), to obtain the average hot leg temperature, are installed at each hot leg pipe (two in the upper region and the other two in the lower region around the wall of the hot leg pipe). There is a deviation in temperature distribution in the hot leg pipe due to the sudden changes in the flow direction and area from the reactor core exit to the hot leg pipe. The non-uniform temperature distribution in the hot leg pipe can affect the measurement of the plant parameters such as the reactor power and the reactor coolant flow rate. The following conclusions are reached 1) The non-uniform temperature distribution in the core exit is sustained to some extent through the entire region of hot leg pipe. 2) The temperature ranges having a uniform pattern are 45 - 120° and 240 - 315°. The sensor positions of RTDs are located in this interval (45 - 120° and 240 - 315°) and this sensor positions of RTDs show the appropriate temperature measurement. Also, the temperature distribution shows the similar pattern without reference to the flow rate variation in RCS.
International Nuclear Information System (INIS)
Coppe, Jean-Philippe; Xu Zhida; Chen Yi; Logan Liu, G
2011-01-01
Molecular probe arrays printed on solid surfaces such as DNA, peptide, and protein microarrays are widely used in chemical and biomedical applications especially genomic and proteomic studies (Pollack et al 1999 Nat. Genet. 23 41-6, Houseman et al 2002 Nat. Biotechnol. 20 270-4, Sauer et al 2005 Nat. Rev. Genet. 6 465-76) as well as surface imaging and spectroscopy (Mori et al 2008 Anal. Biochem. 375 223-31, Liu et al 2006 Nat. Nanotechnol. 1 47-52, Liu 2010 IEEE J. Sel. Top. Quantum Electron. 16 662-71). Unfortunately the printed molecular spots on solid surfaces often suffer low distribution uniformity due to the lingering 'coffee stain' (Deegan et al 1997 Nature 389 827-9) problem of molecular accumulations and blotches, especially around the edge of deposition spots caused by solvent evaporation and convection processes. Here we present, without any surface chemistry modification, a unique solid surface of high-aspect-ratio silver-coated silicon nanocone arrays that allows highly uniform molecular deposition and thus subsequent uniform optical imaging and spectroscopic molecular detection. Both fluorescent Rhodamine dye molecules and unlabeled oligopeptides are printed on the metallic nanocone photonic substrate surface as circular spot arrays. In comparison with the printed results on ordinary glass slides and silver-coated glass slides, not only high printing density but uniform molecular distribution in every deposited spot is achieved. The high-uniformity and repeatability of molecular depositions on the 'coffee stain'-free nanocone surface is confirmed by laser scanning fluorescence imaging and surface enhanced Raman imaging experiments. The physical mechanism for the uniform molecular deposition is attributed to the superhydrophobicity and localized pinned liquid-solid-air interface on the silver-coated silicon nanocone surface. The unique surface properties of the presented nanocone surface enabled high-density, high-uniformity probe spotting beneficial
Inverse analysis of non-uniform temperature distributions using multispectral pyrometry
Fu, Tairan; Duan, Minghao; Tian, Jibin; Shi, Congling
2016-05-01
Optical diagnostics can be used to obtain sub-pixel temperature information in remote sensing. A multispectral pyrometry method was developed using multiple spectral radiation intensities to deduce the temperature area distribution in the measurement region. The method transforms a spot multispectral pyrometer with a fixed field of view into a pyrometer with enhanced spatial resolution that can give sub-pixel temperature information from a "one pixel" measurement region. A temperature area fraction function was defined to represent the spatial temperature distribution in the measurement region. The method is illustrated by simulations of a multispectral pyrometer with a spectral range of 8.0-13.0 μm measuring a non-isothermal region with a temperature range of 500-800 K in the spot pyrometer field of view. The inverse algorithm for the sub-pixel temperature distribution (temperature area fractions) in the "one pixel" verifies this multispectral pyrometry method. The results show that an improved Levenberg-Marquardt algorithm is effective for this ill-posed inverse problem with relative errors in the temperature area fractions of (-3%, 3%) for most of the temperatures. The analysis provides a valuable reference for the use of spot multispectral pyrometers for sub-pixel temperature distributions in remote sensing measurements.
Development of the systems for uniform target irradiation
International Nuclear Information System (INIS)
Voronin, A.Yu.; Garanin, S.G.; Derkach, V.N.; Zhidkov, N.V.; Kravchenko, A.G.; Petrazhitskaya, N.A.; Starodubtsev, K.V.; Sukharev, S.A.; Shnyagin, R.A.
2010-01-01
Complete text of publication follows. The new devices have been developed for laser beams homogenizing in the focal spot - multi-component lens raster and raster with the edges smoothing phase mask. The envelope non-uniformity of -4 radians. Investigation into the temporary-spatial smoothing with the use of low-density foams with the density less than the critical one is still in progress. Experiments on the foams with the density of 1-2.3 mg/cm 3 , thickness of 100-200 μm, and the cells' sizes up to the tens of micrometers were carried out with the radiation wavelength of 0.657 μm. The RMS non-uniformity < 5% has been found for the beam passed through the foam. The non-uniformity is evenly distributed over the spatial frequency spectrum. The induced divergence of radiation is measured to be 0.35 radian. The frequency of the rearranged speckled field of about 2 THz was obtained. The beam smoothing was recorded from the start of pulse of radiation, had the duration up to 1 ns, and the width of the radiation spectrum was about 30 A. The work was performed in part under the sponsorship of the RFFI (grants No. 09-02-12157-ofi-m and No. 09-02-97095-r-povolzh'ye-a) and grant of the President of the RF to leading scientific schools No. 65192.2010.2.
Distribution of elements in human spinal cord
International Nuclear Information System (INIS)
Yukawa, Masae; Kobayashi, T.; Qiu, Y.; Kameda, N.; Ito, Y.; Otomo, E.
1992-01-01
The distribution of elements in human spinal cord was investigated on unfixed frozen cord material using PIXE technique. Distribution of Cu, Zn and Fe were not uniform in the cross section of the spinal cord and concentrations of these elements were higher in the anterior gray horn than in the other areas, while K and Cl distributed uniformly. The content of K changed along the spinal cord from the cervical to the lumbar level. These findings are discussed in relation to current understanding of the physiology of the spinal cord. (author)
International Nuclear Information System (INIS)
Riera, S; Barrau, J; Rosell, J I; Omri, M; Fréchette, L G
2013-01-01
In this work, an experimental study of a novel microfabricated heat sink configuration that tends to uniform the wall temperature, even with increasing flow temperature, is presented. The design consists of a series of microchannel sections with stepwise varying width. This scheme counteracts the flow temperature increase by reducing the local thermal resistance along the flow path. A test apparatus with uniform heat flux and distributed wall temperature measurements was developed for microchannel heat exchanger characterisation. The energy balance is checked and the temperature distribution is analysed for each test. The results show that the wall temperature decreases slightly along the flow path while the fluid temperature increases, highlighting the strong impact of this approach. For a flow rate of 16 ml/s, the mean thermal resistance of the heat sink is 2,35·10 −5 m 2 ·K/W which enhances the results compared to the millimeter scale channels nearly three-fold. For the same flow rate and a heat flux of 50 W/cm 2 , the temperature uniformity, expressed as the standard deviation of the wall temperature, is around 6 °C
Additive non-uniform random sampling in superimposed fiber Bragg grating strain gauge
International Nuclear Information System (INIS)
Ma, Y C; Liu, H Y; Yan, S B; Li, J M; Tang, J; Yang, Y H; Yang, M W
2013-01-01
This paper demonstrates an additive non-uniform random sampling and interrogation method for dynamic and/or static strain gauge using a reflection spectrum from two superimposed fiber Bragg gratings (FBGs). The superimposed FBGs are designed to generate non-equidistant space of a sensing pulse train in the time domain during dynamic strain gauge. By combining centroid finding with smooth filtering methods, both the interrogation speed and accuracy are improved. A 1.9 kHz dynamic strain is measured by generating an additive non-uniform randomly distributed 2 kHz optical sensing pulse train from a mean 500 Hz triangular periodically changing scanning frequency. (paper)
Non-uniform approximations for sums of discrete m-dependent random variables
Vellaisamy, P.; Cekanavicius, V.
2013-01-01
Non-uniform estimates are obtained for Poisson, compound Poisson, translated Poisson, negative binomial and binomial approximations to sums of of m-dependent integer-valued random variables. Estimates for Wasserstein metric also follow easily from our results. The results are then exemplified by the approximation of Poisson binomial distribution, 2-runs and $m$-dependent $(k_1,k_2)$-events.
Devaney's chaos on uniform limit maps
International Nuclear Information System (INIS)
Yan Kesong; Zeng Fanping; Zhang Gengrong
2011-01-01
Highlights: → The transitivity may not been inherited even if the sequence functions mixing. → The sensitivity may not been inherited even if the iterates of sequence have some uniform convergence. → Some equivalence conditions for the transitivity and sensitivity for uniform limit function are given. → A non-transitive sequence may converge uniformly to a transitive map. - Abstract: Let (X, d) be a compact metric space and f n : X → X a sequence of continuous maps such that (f n ) converges uniformly to a map f. The purpose of this paper is to study the Devaney's chaos on the uniform limit f. On the one hand, we show that f is not necessarily transitive even if all f n mixing, and the sensitive dependence on initial conditions may not been inherited to f even if the iterates of the sequence have some uniform convergence, which correct two wrong claims in . On the other hand, we give some equivalence conditions for the uniform limit f to be transitive and to have sensitive dependence on initial conditions. Moreover, we present an example to show that a non-transitive sequence may converge uniformly to a transitive map.
Theoretical impact of insecticide-impregnated school uniforms on dengue incidence in Thai children
Directory of Open Access Journals (Sweden)
Eduardo Massad
2013-03-01
Full Text Available Background: Children carry the main burden of morbidity and mortality caused by dengue. Children spend a considerable amount of their day at school; hence strategies that reduce human–mosquito contact to protect against the day-biting habits of Aedes mosquitoes at schools, such as insecticide-impregnated uniforms, could be an effective prevention strategy. Methodology: We used mathematical models to calculate the risk of dengue infection based on force of infection taking into account the estimated proportion of mosquito bites that occur in school and the proportion of school time that children wear the impregnated uniforms. Principal findings: The use of insecticide-impregnated uniforms has efficacy varying from around 6% in the most pessimistic estimations, to 55% in the most optimistic scenarios simulated. Conclusions: Reducing contact between mosquito bites and human hosts via insecticide-treated uniforms during school time is theoretically effective in reducing dengue incidence and may be a valuable additional tool for dengue control in school-aged children. The efficacy of this strategy, however, is dependent on the compliance of the target population in terms of proper and consistent wearing of uniforms and, perhaps more importantly, the proportion of bites inflicted by the Aedes population during school time.
Bridge density functional approximation for non-uniform hard core repulsive Yukawa fluid
International Nuclear Information System (INIS)
Zhou Shiqi
2008-01-01
In this work, a bridge density functional approximation (BDFA) (J. Chem. Phys. 112, 8079 (2000)) for a non-uniform hard-sphere fluid is extended to a non-uniform hard-core repulsive Yukawa (HCRY) fluid. It is found that the choice of a bulk bridge functional approximation is crucial for both a uniform HCRY fluid and a non-uniform HCRY fluid. A new bridge functional approximation is proposed, which can accurately predict the radial distribution function of the bulk HCRY fluid. With the new bridge functional approximation and its associated bulk second order direct correlation function as input, the BDFA can be used to well calculate the density profile of the HCRY fluid subjected to the influence of varying external fields, and the theoretical predictions are in good agreement with the corresponding simulation data. The calculated results indicate that the present BDFA captures quantitatively the phenomena such as the coexistence of solid-like high density phase and low density gas phase, and the adsorption properties of the HCRY fluid, which qualitatively differ from those of the fluids combining both hard-core repulsion and an attractive tail. (condensed matter: structure, thermal and mechanical properties)
Zhao, Zhili; Zhang, Honghai; Zheng, Huai; Liu, Sheng
2018-03-01
In light-emitting diode (LED) array illumination (e.g. LED backlighting), obtainment of high uniformity in the harsh condition of the large distance height ratio (DHR), extended source and near field is a key as well as challenging issue. In this study, we present a new reversing freeform lens design algorithm based on the illuminance distribution function (IDF) instead of the traditional light intensity distribution, which allows uniform LED illumination in the above mentioned harsh conditions. IDF of freeform lens can be obtained by the proposed mathematical method, considering the effects of large DHR, extended source and near field target at the same time. In order to prove the claims, a slim direct-lit LED backlighting with DHR equal to 4 is designed. In comparison with the traditional lenses, illuminance uniformity of LED backlighting with the new lens increases significantly from 0.45 to 0.84, and CV(RMSE) decreases dramatically from 0.24 to 0.03 in the harsh condition. Meanwhile, luminance uniformity of LED backlighting with the new lens is obtained as high as 0.92 at the condition of extended source and near field. This new method provides a practical and effective way to solve the problem of large DHR, extended source and near field for LED array illumination.
International Nuclear Information System (INIS)
Guskova, A.; Barabanova, A
1996-01-01
Experience in diagnosis and treatment of radiation accident victims undergone to radiation expose with non-uniform distribution of the dose within a body is presented and the most significant features of medical management of such patients are discussed. The term 'compound radiation injure' is proposed to use for this form of radiation disease. Treatment of compound radiation injure demands a participation of very qualified specialists. The first medical aid and management should include careful body surface monitoring. Beside daily haematological observation and cytogenetic study with corresponding treatment, careful observation and registration of skin reaction are necessary. Some features of treatment are the following: more early administration of anti infection means, including isolation in sterile room, timely surgical intervention, prophylacsis and treatment of endorganic intoxication improving of microcirculation, long time follow up study with pathogenic therapy. (author)
International Nuclear Information System (INIS)
Tian, C.; Shan, L.; Zhang, B.; Zhou, W.; Liu, D.; Bi, B.; Zhang, F.; Wang, W.; Zhang, B.; Giu, Y.
2015-01-01
The direct drive irradiation uniformity during the initial imprinting phase at the SG-III prototype laser facility is analyzed and optimized with different methods. At first, the polar direct drive technique is applied to reduce the root mean square deviation σ from 16.1% to 6.4%. To further reduce the non-uniformity, we propose a new method by adjusting the intensity distribution of the laser spot. The overlap of laser beams on the capsule surface is studied and a factor is introduced to adjust the intensity of the laser spot for achieving absolute irradiation uniformity while bringing wild intensity change at laser spot edges. Noting that the overlapping region at the capsule surface is symmetrically distributed, the contribution of light from the edge of a spot can be transferred to its own internal. The newly adjusted intensity distributes at two main regions and the intensity varies slowly and continuously in each, further reducing σ to about 0.35%. Taken into account that the adjusted intensity has very sharp steps, super-Gaussian spatial profiles are used to approximate the required intensity to make it more practicable, which leads σ to 0.94%. Furthermore, sensitivity analysis to beam errors is performed and results show that this scheme can tolerate a certain amount of uncertainties. (authors)
Many-junction photovoltaic device performance under non-uniform high-concentration illumination
Valdivia, Christopher E.; Wilkins, Matthew M.; Chahal, Sanmeet S.; Proulx, Francine; Provost, Philippe-Olivier; Masson, Denis P.; Fafard, Simon; Hinzer, Karin
2017-09-01
A parameterized 3D distributed circuit model was developed to calculate the performance of III-V solar cells and photonic power converters (PPC) with a variable number of epitaxial vertically-stacked pn junctions. PPC devices are designed with many pn junctions to realize higher voltages and to operate under non-uniform illumination profiles from a laser or LED. Performance impacts of non-uniform illumination were greatly reduced with increasing number of junctions, with simulations comparing PPC devices with 3 to 20 junctions. Experimental results using Azastra Opto's 12- and 20-junction PPC illuminated by an 845 nm diode laser show high performance even with a small gap between the PPC and optical fiber output, until the local tunnel junction limit is reached.
Effect of bed configuration on pebble flow uniformity and stagnation in the pebble bed reactor
International Nuclear Information System (INIS)
Gui, Nan; Yang, Xingtuan; Tu, Jiyuan; Jiang, Shengyao
2014-01-01
Highlights: • Pebble flow uniformity and stagnation characteristics are very important for HTR-PM. • Arc- and brachistochrone-shaped configuration effects are studied by DEM simulation. • Best bed configurations with uniform flow and no stagnated pebbles are suggested. • Detailed quantified characteristics of bed configuration effects are shown for explanation. - Abstract: Pebble flow uniformity and stagnation characteristics are very important for the design of pebble bed high temperature gas-cooled reactor. Pebble flows inside some specifically designed contraction configurations of pebble bed are studied by discrete element method. The results show the characteristics of stagnation rates, recycling rates, radial distribution of pebble velocity and residence time. It is demonstrated clearly that the bed with a brachistochrone-shaped configuration achieves optimum levels of flow uniformity and recycling rate concentration, and almost no pebbles are stagnated in the bed. Moreover, the optimum choice among the arc-shaped bed configurations is demonstrated too. Detailed information shows the quantified characteristics of bed configuration effects on flow uniformity. In addition, a good design of the pebble bed configuration is suggested
A uniform approach for programming distributed heterogeneous computing systems.
Grasso, Ivan; Pellegrini, Simone; Cosenza, Biagio; Fahringer, Thomas
2014-12-01
Large-scale compute clusters of heterogeneous nodes equipped with multi-core CPUs and GPUs are getting increasingly popular in the scientific community. However, such systems require a combination of different programming paradigms making application development very challenging. In this article we introduce libWater, a library-based extension of the OpenCL programming model that simplifies the development of heterogeneous distributed applications. libWater consists of a simple interface, which is a transparent abstraction of the underlying distributed architecture, offering advanced features such as inter-context and inter-node device synchronization. It provides a runtime system which tracks dependency information enforced by event synchronization to dynamically build a DAG of commands, on which we automatically apply two optimizations: collective communication pattern detection and device-host-device copy removal. We assess libWater's performance in three compute clusters available from the Vienna Scientific Cluster, the Barcelona Supercomputing Center and the University of Innsbruck, demonstrating improved performance and scaling with different test applications and configurations.
Influence of carbon black distribution on performance of oxide cathodes for Li ion batteries
International Nuclear Information System (INIS)
Dominko, Robert; Gaberscek, Miran; Drofenik, Jernej; Bele, Marjan; Jamnik, Janez
2003-01-01
The influence of carbon black content and carbon black distribution on performance of oxide-based cathodes, such as LiCoO 2 and LiMn 2 O 4 , is investigated. The electronic conductivity of oxide material/carbon black composites is compared with electrochemical characteristics of the same composites. Uniformity of carbon black distribution in cathode composites is achieved using novel coating technology in cathode preparation. In this technology, the active particles are first pretreated in a gelatin solution. The adsorbed gelatin then controls the deposition of carbon black so that carbon black particles are uniformly distributed in the final composite. The influence of various parameters, such as pH of gelatin, amount of gelatin and concentration of carbon black on the uniformity of carbon black distribution is investigated. It is shown that the conventional technology of cathode preparation yields quite non-uniform distribution of carbon black in cathode material. At the end, we demonstrate that uniformity of carbon black distribution has a crucial impact on reversible capacity, especially at high current densities
Wang, Lei; Qiu, Feng; Ouyang, Licheng; Wang, Huiyuan; Zha, Min; Shu, Shili; Zhao, Qinglong; Jiang, Qichuan
2015-12-17
Nano-sized TiC x /2009Al composites (with 5, 7, and 9 vol% TiC x ) were fabricated via the combustion synthesis of the 2009Al-Ti-CNTs system combined with vacuum hot pressing followed by hot extrusion. In the present study, CNTs were used as the carbon source to synthesize nano-sized TiC x particles. An attempt was made to correlate the effect of ground CNTs by milling and the distribution of synthesized nano-sized TiC x particles in 2009Al as well as the tensile properties of nano-sized TiC x /2009Al composites. Microstructure analysis showed that when ground CNTs were used, the synthesized nano-sized TiC x particles dispersed more uniformly in the 2009Al matrix. Moreover, when 2 h-milled CNTs were used, the 5, 7, and 9 vol% nano-sized TiC x /2009Al composites had the highest tensile properties, especially, the 9 vol% nano-sized TiC x /2009Al composites. The results offered a new approach to improve the distribution of in situ nano-sized TiC x particles and tensile properties of composites.
International Nuclear Information System (INIS)
Mu Qinghui; Li Yaogang; Zhang Qinghong; Wang Hongzhi
2011-01-01
Graphical abstract: - Abstract: High-density arrays of vertically oriented TiO 2 nanorods with uniform distribution on Ti foil have been formed through template-free oxidation of Ti in hydrogen peroxide solutions. Subsequent thermal treatment was applied for growing mixed crystal structures to pursue higher performance. Morphology characterization using field emission scanning electron microscopy (FESEM) shows a nanorod diameter in the range of 20-50 nm with a length of 1.5 μm. X-ray diffraction (XRD) measurement demonstrates the crystallization of the TiO 2 nanorods prior to thermal treatment and the formation of anatase and rutile mixed phase after thermal treatment. The mixed crystal TiO 2 nanorods show a much higher performance than pure anatase in photoelectrochemical experiments. Steady-state photocurrent resulted from photocatalytic oxidation of organic compounds by TiO 2 nanorods is employed as response signal in determination of the organics to yield a linear range of 0-1.1 mM for glucose. For other organics, an excellent linear relationship between the net steady-state photocurrent and the concentration of electrons transferred in exhaustive oxidation for these organics is obtained, which empowers the mixed crystal TiO 2 nanorods to serve as versatile material in organics-sensing application.
Indian Academy of Sciences (India)
First page Back Continue Last page Overview Graphics. Conclusions: Extended objects – “D-branes” – appear naturally in theories of strings. They manifest themselves as new types of physical particles in string models. They provide a powerful handle on the symmetries and dynamics of strings. Branes will play a key role ...
Indian Academy of Sciences (India)
First page Back Continue Last page Overview Graphics. Conclusions. Be it 2G or 4G, networks are vulnerable to unwanted access and thus should be protected. 4G networks would be more sensitive as its core network will be TCP/IP based. Accordingly, resource and security management schemes with seamless ...
Photoionization microscopy of Rydberg hydrogen atom in a non-uniform electrical field
International Nuclear Information System (INIS)
Cheng Shao-Hao; Wang De-Hua; Chen Zhao-Hang; Chen Qiang
2016-01-01
In this paper, we investigate the photoionization microscopy of the Rydberg hydrogen atom in a gradient electric field for the first time. The observed oscillatory patterns in the photoionization microscopy are explained within the framework of the semiclassical theory, which can be considered as a manifestation of interference between various electron trajectories arriving at a given point on the detector plane. In contrast with the photoionization microscopy in the uniform electric field, the trajectories of the ionized electron in the gradient electric field will become chaotic. An infinite set of different electron trajectories can arrive at a given point on the detector plane, which makes the interference pattern of the electron probability density distribution extremely complicated. Our calculation results suggest that the oscillatory pattern in the electron probability density distribution depends sensitively on the electric field gradient, the scaled energy and the position of the detector plane. Through our research, we predict that the interference pattern in the electron probability density distribution can be observed in an actual photoionization microscopy experiment once the external electric field strength and the position of the electron detector plane are reasonable. This study provides some references for the future experimental research on the photoionization microscopy of the Rydberg atom in the non-uniform external fields. (paper)
International Nuclear Information System (INIS)
MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.
2000-01-01
also the high dose volume. The optimization on dose points and geometry provides the most uniform dose distribution. The dose non-uniformity ratio can be minimized by selecting the isodose line of the midpoints between the catheters in the whole volume for the dose prescription, but the dose coverage may not be adequate. For a clinically acceptable plan, a compromise should be made between dose non-uniformity and coverage. (author)
School Uniforms. Research Brief
Walker, Karen
2007-01-01
Does clothing make the person or does the person make the clothing? How does what attire a student wears to school affect their academic achievement? In 1996, President Clinton cited examples of school violence and discipline issues that might have been avoided had the students been wearing uniforms ("School uniforms: Prevention or suppression?").…
Indian Academy of Sciences (India)
First page Back Continue Last page Overview Graphics. Conclusions : No dramatic difference in the dynamics of anion-water and water-water hydrogen bonds are found for Cl- and Br- ions. Solvation shells of these ions are not rigid. For OH- in water, HB dynamics in the hydration shell determines the rate of proton transfer.
Optimal distribution of temperature points in μSR measurement of local field
International Nuclear Information System (INIS)
Pełka, R.; Zieliński, P.M.; Konieczny, P.; Wasiutyński, T.
2013-01-01
Three possible distributions of temperature points in the μSR measurement of local field (order parameter) are discussed. The least square method is applied to estimate the scale of the deviations of the fitted parameters from the true values. It indicates that the distribution corresponding to a uniform section of the order parameter values (uniform-in-signal) incurs the smallest errors. The distribution constructed on the basis of the zeros of the Chebyshev polynomials yields comparable uncertainties, while the uniform-in-temperature distribution turns out to be least effective incurring considerably larger errors. These findings can be useful while planning an order parameter measurement in the μSR experiment
Directory of Open Access Journals (Sweden)
Sygut P.
2016-06-01
Full Text Available The paper presents the results of theoretical studies influence of non-uniform temperature distribution along the feedstock length to the unit friction force working on the metal contact surface with the roll change during the round bars 70 mm in diameter continuous rolling process. This value is one of the major factors affecting the grooves wear during the rolling process. The studies were carried out based on the actual engineering data for 160 × 160 mm square cross-section feedstock of steel S355J0. Numerical modelling of the rolling process was performed using Forge2008®, a finite-element based computer program.
Effective electrodiffusion equation for non-uniform nanochannels.
Marini Bettolo Marconi, Umberto; Melchionna, Simone; Pagonabarraga, Ignacio
2013-06-28
We derive a one-dimensional formulation of the Planck-Nernst-Poisson equation to describe the dynamics of a symmetric binary electrolyte in channels whose section is nanometric and varies along the axial direction. The approach is in the spirit of the Fick-Jacobs diffusion equation and leads to a system of coupled equations for the partial densities which depends on the charge sitting at the walls in a non-trivial fashion. We consider two kinds of non-uniformities, those due to the spatial variation of charge distribution and those due to the shape variation of the pore and report one- and three-dimensional solutions of the electrokinetic equations.
Flow distribution in the inlet plenum of steam generator
International Nuclear Information System (INIS)
Khadamakar, H.P.; Patwardhan, A.W.; Padmakumar, G.; Vaidyanathan, G.
2011-01-01
Highlights: → Various flow distribution devices have been studied to make the flow distribution uniform in axial as well as tangential direction. → Experiments were performed using Ultrasonic Velocity Profiler (UVP) and Particle Image Velocimetry (PIV). → CFD modeling has been carried out to give more insights. → Various flow distribution devices have been compared. - Abstract: The flow distribution in a 1/5th and 1/8th scale models of inlet plenum of steam generator (SG) has been studied by a combination of experiments and Computational Fluid Dynamics (CFD) simulations. The distribution of liquid sodium in the inlet plenum of the SG strongly affects the thermal as well as mechanical performance of the steam generator. Various flow distribution devices have been used to make the flow distribution uniform in axial as well as tangential direction in the window region. Experiments have been conducted to measure the radial velocity distribution using Ultrasonic Velocity Profiler (UVP) and Particle Image Velocimetry (PIV) under a variety of conditions. CFD modeling has been carried out for various configurations to give more insight into the flow distribution phenomena. The various flow distribution devices have been compared on the basis of a non-uniformity index parameter.
The mathematical description of uniformity and related theorems
International Nuclear Information System (INIS)
Luo Chuanwen; Yi Chundi; Wang Gang; Li Longsuo; Wang Chuncheng
2009-01-01
Uniform index is a conception that can describe the uniformity of a finite point set in a polyhedron, and is closely related to chaos. In order to study uniform index, the concept of contained uniform index is defined, which is similar to uniform index and has good mathematical properties. In this paper, we prove the convergence of the contained uniform index, and develop the base of proving the convergence of uniform index.
Bone-Marrow Stem-Cell Survival in the Non-Uniformly Exposed Mammal
Energy Technology Data Exchange (ETDEWEB)
Bond, V. P.; Robinson, C. V. [Brookhaven National Laboratory, Medical Research Center, Upton, Long Island, NY (United States)
1967-07-15
For comparison of the effectiveness of non-uniform versus uniform irradiations in causing haematological death in mammals, a model of the irradiated haemopoietic system has been proposed. The essential features of this model are: (1) that different parts of the haemopoietic system have numbers of stem cells which are proportioned to the amounts of active marrow in those parts as measured by {sup 59}Fe uptake, (2) that stem cells in the different parts are subject to the, same dose-survival relationship, and (3) that survival of the animal depends on survival of a critical fraction of the total number of stem cells independent of their distribution among the parts of the total marrow mass. To apply this model one needs to know: (a) the relative {sup 59}Fe uptakes of the different parts of the haemopoietic system, (b) the doses delivered to those parts by each of the exposures to be compared, and (c) the dose-survival curve applicable to the stem cells. From these one can calculate the fraction of stem cells surviving each exposure. In a preliminary communication the applicability of the model was investigated using data obtained entirely from the literature. Additional data, particularly on bone-marrow distribution, have since been obtained and are included here. The primary object of the present paper is to test further the validity of the above 'stem-cell survival model'. Data on bilateral (essentially uniform) versus unilateral and non-uniform rotational exposures in mammals are examined with respect to the surviving fraction of stem cells at the LD{sub 50/30} day dose level. Although an adequate test is not possible at present for lack of a full set of data in any one species, a partial test indicates compatibility with data for dogs and rats. Other possible mortality determinants such as doses or exposures at entrance, midline or exit, or the gram-rads or average dose to the marrow, appear to be less useful than the critical stem-cell survival fraction.
Flexural torsional buckling of uniformly compressed beam-like structures
Ferretti, M.
2018-02-01
A Timoshenko beam model embedded in a 3D space is introduced for buckling analysis of multi-store buildings, made by rigid floors connected by elastic columns. The beam model is developed via a direct approach, and the constitutive law, accounting for prestress forces, is deduced via a suitable homogenization procedure. The bifurcation analysis for the case of uniformly compressed buildings is then addressed, and numerical results concerning the Timoshenko model are compared with 3D finite element analyses. Finally, some conclusions and perspectives are drawn.
Uniform Gauss-Weight Quadratures for Discrete Ordinate Transport Calculations
International Nuclear Information System (INIS)
Carew, John F.; Hu, Kai; Zamonsky, Gabriel
2000-01-01
Recently, a uniform equal-weight quadrature set, UE n , and a uniform Gauss-weight quadrature set, UG n , have been derived. These quadratures have the advantage over the standard level-symmetric LQ n quadrature sets in that the weights are positive for all orders,and the transport solution may be systematically converged by increasing the order of the quadrature set. As the order of the quadrature is increased,the points approach a uniform continuous distribution on the unit sphere,and the quadrature is invariant with respect to spatial rotations. The numerical integrals converge for continuous functions as the order of the quadrature is increased.The numerical characteristics of the UE n quadrature set have been investigated previously. In this paper, numerical calculations are performed to evaluate the application of the UG n quadrature set in typical transport analyses. A series of DORT transport calculations of the >1-MeV neutron flux have been performed for a set of pressure-vessel fluence benchmark problems. These calculations employed the UG n (n = 8, 12, 16, 24, and 32) quadratures and indicate that the UG n solutions have converged to within ∼0.25%. The converged UG n solutions are found to be comparable to the UE n results and are more accurate than the level-symmetric S 16 predictions
Uniform Statistical Convergence on Time Scales
Directory of Open Access Journals (Sweden)
Yavuz Altin
2014-01-01
Full Text Available We will introduce the concept of m- and (λ,m-uniform density of a set and m- and (λ,m-uniform statistical convergence on an arbitrary time scale. However, we will define m-uniform Cauchy function on a time scale. Furthermore, some relations about these new notions are also obtained.
Effects of fixture rotation on coating uniformity for high-performance optical filter fabrication
Rubin, Binyamin; George, Jason; Singhal, Riju
2018-04-01
Coating uniformity is critical in fabricating high-performance optical filters by various vacuum deposition methods. Simple and planetary rotation systems with shadow masks are used to achieve the required uniformity [J. B. Oliver and D. Talbot, Appl. Optics 45, 13, 3097 (2006); O. Lyngnes, K. Kraus, A. Ode and T. Erguder, in `Method for Designing Coating Thickness Uniformity Shadow Masks for Deposition Systems with a Planetary Fixture', 2014 Technical Conference Proceedings, Optical Coatings, August 13, 2014, DOI: 10.14332/svc14.proc.1817.]. In this work, we discuss the effect of rotation pattern and speed on thickness uniformity in an ion beam sputter deposition system. Numerical modeling is used to determine statistical distribution of random thickness errors in coating layers. The relationship between thickness tolerance and production yield are simulated theoretically and demonstrated experimentally. Production yields for different optical filters produced in an ion beam deposition system with planetary rotation are presented. Single-wavelength and broadband optical monitoring systems were used for endpoint monitoring during filter deposition. Limitations of thickness tolerances that can be achieved in systems with planetary rotation are shown. Paths for improving production yield in an ion beam deposition system are described.
Directory of Open Access Journals (Sweden)
Stefan Leger
2017-10-01
Conclusion: The proposed PCM algorithm led to a significantly improved image quality compared to the originally acquired images, suggesting that it is applicable to the correction of MRI data. Thus it may help to reduce intensity non-uniformity which is an important step for advanced image analysis.
The Influence of nonuniform activity distribution on cellular dosimetry
International Nuclear Information System (INIS)
Naling, Song; Yuan, Tian; Liangan, Zhang; Guangfu, Dai
2008-01-01
S value is an important parameter in determination of absorbed dose in nuclear medicine and radiobiology. The distribution of radioactivity shows significant influence on the S value especially in microdosimetry. In present work, a semi Monte Carlo Model is developed to calculate the microdosimetric cellular S value for different micro-distributions of radioactivity, i.e. uniform, linear increase, linear decrease, exponential increase, exponential decrease and centroid distribution. Emission of alpha particles is simulated by Monte Carlo model and the energy imparted to the target volume is calculated by the analytical Continuous Slowing Down Approximation (CSDA) model and the spline interpolation of range-energy relationship. We calculate tables of S values for 213 Po and 210 Po with various dimensions and most important with various possible micro-distributions of radioactivity, such as linear increase, linear decrease, exponential increase and exponential decrease. Then we compare the S values from cell to cell of uniform distribution with the Hamacher's results to test the feasibility of our model. S values of some nonuniform micro-distributions are compared to the corresponding data of the uniform distribution. The possible sources of these differences are theoretical analyzed. (author)
Park, Jinil; Shin, Taehoon; Yoon, Soon Ho; Goo, Jin Mo; Park, Jang-Yeon
2016-05-01
The purpose of this work was to develop a 3D radial-sampling strategy which maintains uniform k-space sample density after retrospective respiratory gating, and demonstrate its feasibility in free-breathing ultrashort-echo-time lung MRI. A multi-shot, interleaved 3D radial sampling function was designed by segmenting a single-shot trajectory of projection views such that each interleaf samples k-space in an incoherent fashion. An optimal segmentation factor for the interleaved acquisition was derived based on an approximate model of respiratory patterns such that radial interleaves are evenly accepted during the retrospective gating. The optimality of the proposed sampling scheme was tested by numerical simulations and phantom experiments using human respiratory waveforms. Retrospectively, respiratory-gated, free-breathing lung MRI with the proposed sampling strategy was performed in healthy subjects. The simulation yielded the most uniform k-space sample density with the optimal segmentation factor, as evidenced by the smallest standard deviation of the number of neighboring samples as well as minimal side-lobe energy in the point spread function. The optimality of the proposed scheme was also confirmed by minimal image artifacts in phantom images. Human lung images showed that the proposed sampling scheme significantly reduced streak and ring artifacts compared with the conventional retrospective respiratory gating while suppressing motion-related blurring compared with full sampling without respiratory gating. In conclusion, the proposed 3D radial-sampling scheme can effectively suppress the image artifacts due to non-uniform k-space sample density in retrospectively respiratory-gated lung MRI by uniformly distributing gated radial views across the k-space. Copyright © 2016 John Wiley & Sons, Ltd.
7 CFR 1006.61 - Computation of uniform prices.
2010-01-01
..., the market administrator shall compute a uniform butterfat price, a uniform skim milk price, and a... section. (b) Uniform skim milk price. The uniform skim milk price per hundredweight, rounded to the... paragraph (a) of this section times 3.5 pounds of butterfat; and (2) Multiply the uniform skim milk price...
7 CFR 1131.61 - Computation of uniform prices.
2010-01-01
..., the market administrator shall compute a uniform butterfat price, a uniform skim milk price, and a... section. (b) Uniform skim milk price. The uniform skim milk price per hundredweight, rounded to the... paragraph (a) of this section times 3.5 pounds of butterfat; and (2) Multiply the uniform skim milk price...
7 CFR 1007.61 - Computation of uniform prices.
2010-01-01
..., the market administrator shall compute a uniform butterfat price, a uniform skim milk price, and a... section. (b) Uniform skim milk price. The uniform skim milk price per hundredweight, rounded to the... paragraph (a) of this section times 3.5 pounds of butterfat; and (2) Multiply the uniform skim milk price...
7 CFR 1005.61 - Computation of uniform prices.
2010-01-01
... month, the market administrator shall compute a uniform butterfat price, a uniform skim milk price, and...) and (a)(2) of this section. (b) Uniform skim milk price. The uniform skim milk price per hundredweight... paragraph (a) of this section times 3.5 pounds of butterfat; and (2) Multiply the uniform skim milk price...
Measurement of reactivity effect caused by nonuniform fuel distribution
International Nuclear Information System (INIS)
Yamane, Yoshihiro; Hirano, Yasushi; Yasui, Hazime; Nishina, Kojiro; Shiroya, Seiji
1991-01-01
A reactivity effect due to a spatial variation of nuclear fuel concentration is an important problem in a reprocessing plant. To estimate this reactivity effect theoretically, the ''Goertzel's necessary condition, and th Fuel Importance'' theory have been proposed. In order to verify these theories, we have performed systematic measurements of reactivity effect due to the nonuniformity in the fuel distribution within the Kyoto University Critical Assembly. Neutron flux distribution and Fuel Importance distribution were also determined. A nonuniform assembly whose fuel concentration in the center region was 40% higher than the uniform one was found to have an excess reactivity of 0.3%Δk/k, with the same total uranium mass for which the uniform assembly was just critical. Moreover, its spatial distribution of thermal neutron flux and of Fuel Importance were more flat than those of the uniform assembly, as expected by the Goertzel's condition and the Fuel Importance theory. (Author)
The ciliate Paramecium shows higher motility in non-uniform chemical landscapes.
Directory of Open Access Journals (Sweden)
Carl Giuffre
Full Text Available We study the motility behavior of the unicellular protozoan Paramecium tetraurelia in a microfluidic device that can be prepared with a landscape of attracting or repelling chemicals. We investigate the spatial distribution of the positions of the individuals at different time points with methods from spatial statistics and Poisson random point fields. This makes quantitative the informal notion of "uniform distribution" (or lack thereof. Our device is characterized by the absence of large systematic biases due to gravitation and fluid flow. It has the potential to be applied to the study of other aquatic chemosensitive organisms as well. This may result in better diagnostic devices for environmental pollutants.
Spacetime transformations from a uniformly accelerated frame
International Nuclear Information System (INIS)
Friedman, Yaakov; Scarr, Tzvi
2013-01-01
We use the generalized Fermi–Walker transport to construct a one-parameter family of inertial frames which are instantaneously comoving to a uniformly accelerated observer. We explain the connection between our approach and that of Mashhoon. We show that our solutions of uniformly accelerated motion have constant acceleration in the comoving frame. Assuming the weak hypothesis of locality, we obtain local spacetime transformations from a uniformly accelerated frame K′ to an inertial frame K. The spacetime transformations between two uniformly accelerated frames with the same acceleration are Lorentz. We compute the metric at an arbitrary point of a uniformly accelerated frame. (paper)
The effect of increased irradiation uniformity on imprinting by 351-nm laser light
International Nuclear Information System (INIS)
Boehly, T.R.; Smalyuk, V.A.; Meyerhofer, D.D.; Knauer, J.P.; Bradley, D.K.; Verdon, C.P.; Kalantar, D.
1997-01-01
The acceleration-driven growth of perturbations initially seeded (or imprinted) by irradiation nonuniformities is a major concern for direct-drive ICF. We report on experiments where unperturbed, CH 2 targets were irradiated with 3-ns square pulses at 2x10 14 W/cm 2 using five overlapped UV beams. The uniformity of these beams was varied and subsequent unstable growth of irradiation imprinting was observed using time-gated x-radiography. We demonstrate that increased irradiation uniformity reduces imprinting, and we show the beneficial effects of distributed polarization rotators a new beam-smoothing device. In addition, we discuss experiments using a ' perturbing beam' to study the time dependence of imprinting. copyright 1997 American Institute of Physics
Cellular- and micro-dosimetry of heterogeneously distributed tritium.
Chao, Tsi-Chian; Wang, Chun-Ching; Li, Junli; Li, Chunyan; Tung, Chuan-Jong
2012-01-01
The assessment of radiotoxicity for heterogeneously distributed tritium should be based on the subcellular dose and relative biological effectiveness (RBE) for cell nucleus. In the present work, geometry-dependent absorbed dose and RBE were calculated using Monte Carlo codes for tritium in the cell, cell surface, cytoplasm, or cell nucleus. Penelope (PENetration and Energy LOss of Positrins and Electrons) code was used to calculate the geometry-dependent absorbed dose, lineal energy, and electron fluence spectrum. RBE for the intestinal crypt regeneration was calculated using a lineal energy-dependent biological weighting function. RBE for the induction of DNA double strand breaks was estimated using a nucleotide-level map for clustered DNA lesions of the Monte Carlo damage simulation (MCDS) code. For a typical cell of 10 μm radius and 5 μm nuclear radius, tritium in the cell nucleus resulted in much higher RBE-weighted absorbed dose than tritium distributed uniformly. Conversely, tritium distributed on the cell surface led to trivial RBE-weighted absorbed dose due to irradiation geometry and great attenuation of beta particles in the cytoplasm. For tritium uniformly distributed in the cell, the RBE-weighted absorbed dose was larger compared to tritium uniformly distributed in the tissue. Cellular- and micro-dosimetry models were developed for the assessment of heterogeneously distributed tritium.
Classical understanding of electron vortex beams in a uniform magnetic field
Energy Technology Data Exchange (ETDEWEB)
Han, Yeong Deok [Department of Computer Science and Engineering, Woosuk University, Wanju, Cheonbuk, 565-701 (Korea, Republic of); Choi, Taeseung, E-mail: tschoi@swu.ac.kr [Division of Applied Food System, College of Natural Science, Seoul Women' s University, Seoul 139-774 (Korea, Republic of); School of Computational Sciences, Korea Institute for Advanced Study, Seoul 130-012 (Korea, Republic of)
2017-04-25
Recently, interesting observations on electron vortex beams have been made. We propose a classical model that shows vortex-like motion due to suitably-synchronized motion of each electron's cyclotron motion in a uniform magnetic field. It is shown that some basic features of electron vortex beams in a uniform magnetic field, such as azimuthal currents, the relation between energy and kinetic angular momentum, and the parallel-axis theorem are understandable by using this classical model. We also show that the time-dependence of kinetic angular momentum of electron vortex beams could be understood as an effect of a specific nonuniform distribution of classical electrons. - Highlights: • A classical model for electron vortex beams is proposed. • The basic features of azimuthal currents could be understood by using this model. • The kinetic angular momentum of electron vortex beams is intuitively understandable.
Lu, Jennifer Q; Yi, Sung Soo
2006-04-25
A monolayer of gold-containing surface micelles has been produced by spin-coating solution micelles formed by the self-assembly of the gold-modified polystyrene-b-poly(2-vinylpyridine) block copolymer in toluene. After oxygen plasma removed the block copolymer template, highly ordered and uniformly sized nanoparticles have been generated. Unlike other published methods that require reduction treatments to form gold nanoparticles in the zero-valent state, these as-synthesized nanoparticles are in form of metallic gold. These gold nanoparticles have been demonstrated to be an excellent catalyst system for growing small-diameter silicon nanowires. The uniformly sized gold nanoparticles have promoted the controllable synthesis of silicon nanowires with a narrow diameter distribution. Because of the ability to form a monolayer of surface micelles with a high degree of order, evenly distributed gold nanoparticles have been produced on a surface. As a result, uniformly distributed, high-density silicon nanowires have been generated. The process described herein is fully compatible with existing semiconductor processing techniques and can be readily integrated into device fabrication.
Effects of deltamethrin treated uniform on malaria prophylaxis in troops of Bahawalpur garrison
International Nuclear Information System (INIS)
Younis, M.; Murtaza, G.; Nasir
2017-01-01
Objective: To determine the efficacy of deltamethrin treated uniforms on repellant action against mosquitos in serving soldiers. Study Design: Randomized control trial. Place and Duration of Study: Bahawalpur Garrison, from 18 Aug to 24 Aug 2014. Patient and Methods: Two groups were selected for the study, one group comprising of 100 x soldiers wearing deltamethrin treated uniforms and other group comprising 100 x soldiers wearing non-treated (normal working) uniforms-control group. All soldiers were males, their age ranged from 20 years to 41 year. Uniforms were issued centrally with no group knowing which group has been issued treated uniforms, (double blind study was carried out to eliminate subject bias). Coding system was evolved while issuing the uniforms which were only known to the main researchers, president of the study board. Both the groups were made to sit for one hour in a large training ground of the formation in two separate groups at a distance of 50-60 feet between the groups and 10-15 feet between the individuals. All the individuals were asked to count the number of mosquitos attracted towards them, whether sitting/biting on their uniforms or on their bodies. Mosquito counting was also facilitated by the organizing/conducting staff. The study continued for a week from 18-24 Aug 2014. All soldiers were given 2 x tabs Chloroquine stat as prophylaxis for malaria prior to the study. Mean and SD of no of bites of both groups were compared and analyzed. Student t-test was applied to note the statistical significance among the study groups. Results: Out of the two groups the individuals wearing deltamethrin treated uniforms showed about overall 90 percent protection from mosquitos as compared to the control group. The average number of bites by mosquitoes in the control group was 7/person in one hour, whereas it was less than one bite/person in the case group. Conclusion: This study confirmed that the deltamethrin treated uniform is highly effective in
Energy Technology Data Exchange (ETDEWEB)
Zupančič, Matevž, E-mail: matevz.zupancic@fs.uni-lj.si; Može, Matic; Gregorčič, Peter; Golobič, Iztok
2017-03-31
Highlights: • Surfaces with periodically changed wettability were produced by a ns marking laser. • Heat transfer was investigated on uniformly and non-uniformly wettable surfaces. • Microporous surfaces with non-uniform wettability enhance boiling heat transfer. • The most bubble nucleations were observed in the vicinity of the microcavities. • Results agree with the predictions of the nucleation criteria. - Abstract: Microstructured uniformly and non-uniformly wettable surfaces were created on 25-μm-thin stainless steel foils by laser texturing using a marking nanosecond Nd:YAG laser (λ = 1064 nm) and utilizing various laser fluences and scan line separations. High-speed photography and high-speed IR thermography were used to investigate nucleate boiling heat transfer on the microstructured surfaces. The most pronounced results were obtained on a surface with non-uniform microstructure and non-uniform wettability. The obtained results show up to a 110% higher heat transfer coefficients and 20–40 times higher nucleation site densities compared to the untextured surface. We show that the number of active nucleation sites is significantly increased in the vicinity of microcavities that appeared in areas with the smallest (10 μm) scan line separation. Furthermore, this confirms the predictions of nucleation criteria and proves that straightforward, cost-effective nanosecond laser texturing allows the production of cavities with diameters of up to a few micrometers and surfaces with non-uniform wettability. Additionally, this opens up important possibilities for a more deterministic control over the complex boiling process.
Temperature Uniformity of Wafer on a Large-Sized Susceptor for a Nitride Vertical MOCVD Reactor
International Nuclear Information System (INIS)
Li Zhi-Ming; Jiang Hai-Ying; Han Yan-Bin; Li Jin-Ping; Yin Jian-Qin; Zhang Jin-Cheng
2012-01-01
The effect of coil location on wafer temperature is analyzed in a vertical MOCVD reactor by induction heating. It is observed that the temperature distribution in the wafer with the coils under the graphite susceptor is more uniform than that with the coils around the outside wall of the reactor. For the case of coils under the susceptor, we find that the thickness of the susceptor, the distance from the coils to the susceptor bottom and the coil turns significantly affect the temperature uniformity of the wafer. An optimization process is executed for a 3-inch susceptor with this kind of structure, resulting in a large improvement in the temperature uniformity. A further optimization demonstrates that the new susceptor structure is also suitable for either multiple wafers or large-sized wafers approaching 6 and 8 inches
24 CFR 5.801 - Uniform financial reporting standards.
2010-04-01
... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Uniform financial reporting... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Uniform Financial Reporting Standards § 5.801 Uniform financial reporting standards. (a) Applicability. This subpart H implements uniform...
Decidability of uniform recurrence of morphic sequences
Durand , Fabien
2012-01-01
We prove that the uniform recurrence of morphic sequences is decidable. For this we show that the number of derived sequences of uniformly recurrent morphic sequences is bounded. As a corollary we obtain that uniformly recurrent morphic sequences are primitive substitutive sequences.
Projection-based Bayesian recursive estimation of ARX model with uniform innovations
Czech Academy of Sciences Publication Activity Database
Kárný, Miroslav; Pavelková, Lenka
2007-01-01
Roč. 56, 9/10 (2007), s. 646-655 ISSN 0167-6911 R&D Projects: GA AV ČR 1ET100750401; GA MŠk 2C06001; GA MDS 1F43A/003/120 Institutional research plan: CEZ:AV0Z10750506 Keywords : ARX model * Bayesian recursive estimation * Uniform distribution Subject RIV: BC - Control Systems Theory Impact factor: 1.634, year: 2007 http://dx.doi.org/10.1016/j.sysconle.2007.03.005
School uniforms: tradition, benefit or predicament?
Van Aardt, Annette Marie; Wilken, Ilani
2012-01-01
This article focuses on the controversies surrounding school uniforms. Roleplayers in this debate in South Africa are parents, learners and educators, and arguments centre on aspects such as identity, economy and the equalising effect of school uniforms, which are considered in the literature to be benefits. Opposing viewpoints highlight the fact that compulsory uniforms infringe on learners’ constitutional rights to self-expression. The aim of this research was to determine the perspectives ...
El-Amin, Mohamed; Sun, Shuyu
2010-01-01
In most of real-world applications, such as the case of heat stores, inlet is not kept at a constant temperature but it may vary with time during charging process. In this paper, a vertical water jet injected into a rectangular storage tank is measured experimentally and simulated numerically. Two cases of study are considered; one is a hot water jet with uniform inlet temperature (UIT) injected into a cold water tank, and the other is a cold water jet with non-uniform inlet temperature (NUIT) injected into a hot water tank. Three different temperature differences and three different flow rates are studied for the hot water jet with UIT which is injected into a cold water tank. Also, three different initial temperatures with constant flow rate as well as three different flow rates with constant initial temperature are considered for the cold jet with NUIT which is injected into a hot water tank. Turbulence intensity at the inlet as well as Reynolds number for the NUIT cases are therefore functions of inlet temperature and time. Both experimental measurements and numerical calculations are carried out for the same measured flow and thermal conditions. The realizable k-ε model is used for modeling the turbulent flow. Numerical solutions are obtained for unsteady flow while pressure, velocity, temperature and turbulence distributions inside the water tank are analyzed. The simulated results are compared to the measured results, and they show a good agreement at low temperatures. © 2010 IEEE.
El-Amin, Mohamed
2010-12-01
In most of real-world applications, such as the case of heat stores, inlet is not kept at a constant temperature but it may vary with time during charging process. In this paper, a vertical water jet injected into a rectangular storage tank is measured experimentally and simulated numerically. Two cases of study are considered; one is a hot water jet with uniform inlet temperature (UIT) injected into a cold water tank, and the other is a cold water jet with non-uniform inlet temperature (NUIT) injected into a hot water tank. Three different temperature differences and three different flow rates are studied for the hot water jet with UIT which is injected into a cold water tank. Also, three different initial temperatures with constant flow rate as well as three different flow rates with constant initial temperature are considered for the cold jet with NUIT which is injected into a hot water tank. Turbulence intensity at the inlet as well as Reynolds number for the NUIT cases are therefore functions of inlet temperature and time. Both experimental measurements and numerical calculations are carried out for the same measured flow and thermal conditions. The realizable k-ε model is used for modeling the turbulent flow. Numerical solutions are obtained for unsteady flow while pressure, velocity, temperature and turbulence distributions inside the water tank are analyzed. The simulated results are compared to the measured results, and they show a good agreement at low temperatures. © 2010 IEEE.
Directory of Open Access Journals (Sweden)
Anupam Pathak
2014-11-01
Full Text Available Abstract: Problem Statement: The two-parameter exponentiated Rayleigh distribution has been widely used especially in the modelling of life time event data. It provides a statistical model which has a wide variety of application in many areas and the main advantage is its ability in the context of life time event among other distributions. The uniformly minimum variance unbiased and maximum likelihood estimation methods are the way to estimate the parameters of the distribution. In this study we explore and compare the performance of the uniformly minimum variance unbiased and maximum likelihood estimators of the reliability function R(t=P(X>t and P=P(X>Y for the two-parameter exponentiated Rayleigh distribution. Approach: A new technique of obtaining these parametric functions is introduced in which major role is played by the powers of the parameter(s and the functional forms of the parametric functions to be estimated are not needed. We explore the performance of these estimators numerically under varying conditions. Through the simulation study a comparison are made on the performance of these estimators with respect to the Biasness, Mean Square Error (MSE, 95% confidence length and corresponding coverage percentage. Conclusion: Based on the results of simulation study the UMVUES of R(t and ‘P’ for the two-parameter exponentiated Rayleigh distribution found to be superior than MLES of R(t and ‘P’.
International Nuclear Information System (INIS)
Li Liuhe; Li Jianhui; Kwok, Dixon T. K.; Chu, Paul K.; Wang Zhuo
2009-01-01
Based on the multiple-grid particle-in-cell code, an advanced simulation model is established to study the sheath physics and dose uniformity along the sample stage in order to provide the theoretical basis for further improvement of enhanced glow discharge plasma immersion ion implantation and deposition. At t=7.0 μs, the expansion of the sheath in the horizontal direction is hindered by the dielectric cage. The electron focusing effect is demonstrated by this model. Most of the ions at the inside wall of the cage are implanted into the edge of the sample stage and a relatively uniform ion fluence distribution with a large peak is observed at the end. Compared to the results obtained from the previous model, a higher implant fluence and larger area of uniformity are disclosed.
Lücken, Leonhard; Yanchuk, Serhiy; Popovych, Oleksandr V.; Tass, Peter A.
2013-01-01
Several brain diseases are characterized by abnormal neuronal synchronization. Desynchronization of abnormal neural synchrony is theoretically compelling because of the complex dynamical mechanisms involved. We here present a novel type of coordinated reset (CR) stimulation. CR means to deliver phase resetting stimuli at different neuronal sub-populations sequentially, i.e., at times equidistantly distributed in a stimulation cycle. This uniform timing pattern seems to be intuitive and actually applies to the neural network models used for the study of CR so far. CR resets the population to an unstable cluster state from where it passes through a desynchronized transient, eventually resynchronizing if left unperturbed. In contrast, we show that the optimal stimulation times are non-uniform. Using the model of weakly pulse-coupled neurons with phase response curves, we provide an approach that enables to determine optimal stimulation timing patterns that substantially maximize the desynchronized transient time following the application of CR stimulation. This approach includes an optimization search for clusters in a low-dimensional pulse coupled map. As a consequence, model-specific non-uniformly spaced cluster states cause considerably longer desynchronization transients. Intriguingly, such a desynchronization boost with non-uniform CR stimulation can already be achieved by only slight modifications of the uniform CR timing pattern. Our results suggest that the non-uniformness of the stimulation times can be a medically valuable parameter in the calibration procedure for CR stimulation, where the latter has successfully been used in clinical and pre-clinical studies for the treatment of Parkinson's disease and tinnitus. PMID:23750134
Instruction sequence based non-uniform complexity classes
Bergstra, J.A.; Middelburg, C.A.
2013-01-01
We present an approach to non-uniform complexity in which single-pass instruction sequences play a key part, and answer various questions that arise from this approach. We introduce several kinds of non-uniform complexity classes. One kind includes a counterpart of the well-known non-uniform
School Uniforms: Esprit de Corps.
Ryan, Rosemary P.; Ryan, Thomas E.
1998-01-01
The benefits of school uniforms far outweigh their short-term costs. School uniforms not only keep students safe, but they increase their self-esteem, promote a more positive attitude toward school, lead to improved student behavior, and help blur social-class distinctions. Students are allowed to wear their own political or religious messages,…
Comments on Beckmann's Uniform Reducts
Cook, Stephen
2006-01-01
Arnold Beckmann defined the uniform reduct of a propositional proof system f to be the set of those bounded arithmetical formulas whose propositional translations have polynomial size f-proofs. We prove that the uniform reduct of f + Extended Frege consists of all true bounded arithmetical formulas iff f + Extended Frege simulates every proof system.
Pellicle transmission uniformity requirements
Brown, Thomas L.; Ito, Kunihiro
1998-12-01
Controlling critical dimensions of devices is a constant battle for the photolithography engineer. Current DUV lithographic process exposure latitude is typically 12 to 15% of the total dose. A third of this exposure latitude budget may be used up by a variable related to masking that has not previously received much attention. The emphasis on pellicle transmission has been focused on increasing the average transmission. Much less, attention has been paid to transmission uniformity. This paper explores the total demand on the photospeed latitude budget, the causes of pellicle transmission nonuniformity and examines reasonable expectations for pellicle performance. Modeling is used to examine how the two primary errors in pellicle manufacturing contribute to nonuniformity in transmission. World-class pellicle transmission uniformity standards are discussed and a comparison made between specifications of other components in the photolithographic process. Specifications for other materials or parameters are used as benchmarks to develop a proposed industry standard for pellicle transmission uniformity.
Analyses of the Impact of School Uniforms on Violence in North Carolina Public High Schools
Johnson, Wesley Scott
2010-01-01
This study incorporated a multiple-methods design utilizing both quantitative and qualitative data. The quantitative portion investigated several annual reports distributed by the North Carolina Department of Public Instruction (NCDPI) to explore the impact of school uniform policies on incidents of crime and violence and occurrences of…
Weak completeness of the Bourbaki quasi-uniformity
Directory of Open Access Journals (Sweden)
M.A. Sánchez Granero
2001-04-01
Full Text Available The concept of semicompleteness (weaker than half-completeness is defined for the Bourbaki quasi-uniformity of the hyperspace of a quasi-uniform space. It is proved that the Bourbaki quasi-uniformity is semicomplete in the space of nonempty sets of a quasi-uniform space (X,U if and only if each stable filter on (X,U* has a cluster point in (X,U. As a consequence the space of nonempty sets of a quasi-pseudometric space is semicomplete if and only if the space itself is half-complete. It is also given a characterization of semicompleteness of the space of nonempty U*-compact sets of a quasi-uniform space (X,U which extends the well known Zenor-Morita theorem.
Krupiński, Michał; Bareła, Jaroslaw; Firmanty, Krzysztof; Kastek, Mariusz
2013-10-01
Uneven response of particular detectors (pixels) to the same incident power of infrared radiation is an inherent feature of microbolometer focal plane arrays. As a result an image degradation occurs, known as Fixed Pattern Noise (FPN), which distorts the thermal representation of an observed scene and impairs the parameters of a thermal camera. In order to compensate such non-uniformity, several NUC correction methods are applied in digital data processing modules implemented in thermal cameras. Coefficients required to perform the non-uniformity correction procedure (NUC coefficients) are determined by calibrating the camera against uniform radiation sources (blackbodies). Non-uniformity correction is performed in a digital processing unit in order to remove FPN pattern in the registered thermal images. Relevant correction coefficients are calculated on the basis of recorded detector responses to several values of radiant flux emitted from reference IR radiation sources (blackbodies). The measurement of correction coefficients requires specialized setup, in which uniform, extended radiation sources with high temperature stability are one of key elements. Measurement stand for NUC correction developed in Institute of Optoelectronics, MUT, comprises two integrated extended blackbodies with the following specifications: area 200×200 mm, stabilized absolute temperature range +15 °C÷100 °C, and uniformity of temperature distribution across entire surface +/-0.014 °C. Test stand, method used for the measurement of NUC coefficients and the results obtained during the measurements conducted on a prototype thermal camera will be presented in the paper.
Effect of transverse power distribution on the ONB location in the subcooled boiling flow
International Nuclear Information System (INIS)
Al-Yahia, Omar S.; Lee, Yong Joong; Jo, Daeseong
2017-01-01
Highlights: • Effect of transverse power distribution on ONB incipient. • Uniform and non-uniform heat distribution is simulated in a narrow rectangular channel. • Simulations are performed using CFX and TMAP codes. • For uniform heating, ONB incipient by CFX occurs between predictions by TMAP analyses. • For non-uniform heating, ONB incipient by CFX occurs at a higher power than that by TMAP analysis. - Abstract: This study investigates the effect of transverse power distribution on the ONB (Onset of Nucleate Boiling) incipient. For this purpose, a subcooled boiling model with uniform and non-uniform heat flux distribution is simulated in a narrow vertical rectangular channel heated from both sides by applying a wide range of thermal power (8–16 kW). The simulations are performed using the CFX and TMAP codes. The CFX code incorporates both a two-fluid model and RPI wall boiling model to investigate coolant and wall temperature distributions along the heated channel. The TMAP code implements two different sets of heat transfer correlations to evaluate the wall temperature. The results obtained from the TMAP analyses show that the wall temperatures predicted by the Jo et al. heat transfer correlation are higher than the ones predicted by the Dittus and Boelter heat transfer correlation. The wall temperatures predicted by the CFX analyses lie between the predicted wall temperatures obtained by the TMAP analyses. Based on the superheated temperature on the heated surface, the ONB incipient is determined. The axial locations of the ONB incipient are predicted differently by the CFX and TMAP analyses. For uniform heating, the ONB incipient predicted by the CFX analysis occurs between the predictions made by the TMAP analyses. For non-uniform heating, the ONB incipient by the CFX analysis occurs at a higher power than the power required by the TMAP analyses.
Heterogeneous analysis of non-uniform neutron field formation
International Nuclear Information System (INIS)
Zagrebaev, A.M.; Fedosov, A.M.
1979-01-01
Investigated are the specific features of spatial-energy neutron distribution formation in the transient zone between regions, operating at different levels of energy release with accounting for the real structure of fuel element lattice and control elements in the channel reactors of high power. Presented are the calculation results, obtained by heterogeneous method in the two-group monopole approximation by means of the HETLAT code. The analysis, based on the homogeneous model shows, that the efficiency of the transient zone in forming neutron flux qradient can be increased by introducing an additional interlayer of moderator between the layers with extreme multiplying properties. It is stressed, that the most favourable from the point of view of energy release uniformity in zones and width of the transient zone is the variant in which neutron flux gradient is carried out by moving the control elements on the boundaries of regions while the internal rows of control elements create the conditions for flattening the energy release in the zones. The result obtained corresponds to the recommendation on optimal control, coming from the Pontryagin maximum principle. The analysis of neutron field formation using heterogeneous models mainly proves the conclusions following from homogeneous calculations using the maximum principle. At the same time quantitative results for the zones of small dimensions (less than 10 migration lengths) with a vividly expressed heterogeneous structure essentially differ from the forecast, obtained on the basis of the simplified homogeneous one-group model. The heterogeneous analysis shows possibilities for further optimization of the transient zone structure with account of the control element location
The distribution on trees of dry deposited material from the Chernobyl accident
International Nuclear Information System (INIS)
Roed, J.
1988-01-01
The distribution of material from the Chernobyl accident that has been dry deposited on forest trees near Roskilde (Denmark) and on trees in a suburban area of Roskilde are investigated. The dry deposition velocities on the plan-projected area covered by the trees are found and compared with those on paved surfaces. The conclusion is that the deposited material is distributed fairly uniformly on the trees, and that the deposition velocities on trees are more than 10 times higher than on paved surfaces. A bulk deposition constant is defined and proposed to be used for modelling the deposition on trees in an urban environment. This work was supported by the EEC Radiation Protection Programme under contract No. B16-107-DK and by NKA, the Nordic Liaison Committee for Atomic Energy
46 CFR 310.63 - Uniforms and textbooks.
2010-10-01
... 46 Shipping 8 2010-10-01 2010-10-01 false Uniforms and textbooks. 310.63 Section 310.63 Shipping MARITIME ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRAINING MERCHANT MARINE TRAINING Admission and Training of Midshipmen at the United States Merchant Marine Academy § 310.63 Uniforms and textbooks. The Academy shall supply midshipmen uniforms an...
Energy Technology Data Exchange (ETDEWEB)
Blue, C.A.; Sikka, V.K. [Oak Ridge National Lab., TN (United States); Chun, Jung-Hoon [Massachusetts Institute of Technology, Cambridge, MA (United States); Ando, T. [Tufts Univ., Medford, MA (United States)
1997-04-01
The uniform-droplet process is a new method of liquid-metal atomization that results in single droplets that can be used to produce mono-size powders or sprayed-on to substrates to produce near-net shapes with tailored microstructure. The mono-sized powder-production capability of the uniform-droplet process also has the potential of permitting engineered powder blends to produce components of controlled porosity. Metal and alloy powders are commercially produced by at least three different methods: gas atomization, water atomization, and rotating disk. All three methods produce powders of a broad range in size with a very small yield of fine powders with single-sized droplets that can be used to produce mono-size powders or sprayed-on substrates to produce near-net shapes with tailored microstructures. The economical analysis has shown the process to have the potential of reducing capital cost by 50% and operating cost by 37.5% when applied to powder making. For the spray-forming process, a 25% savings is expected in both the capital and operating costs. The project is jointly carried out at Massachusetts Institute of Technology (MIT), Tuffs University, and Oak Ridge National Laboratory (ORNL). Preliminary interactions with both finished parts and powder producers have shown a strong interest in the uniform-droplet process. Systematic studies are being conducted to optimize the process parameters, understand the solidification of droplets and spray deposits, and develop a uniform-droplet-system (UDS) apparatus appropriate for processing engineering alloys.
Uniform Suspension of the Clustered Triamcinolone Acetonide Particle
Directory of Open Access Journals (Sweden)
Masahiko Sugimoto
2013-01-01
Full Text Available Purpose. MaQaid (MaQ is a new triamcinolone acetonide commercialised in Japan to visualize the vitreous. Because MaQ is preservative-free, it has a lower risk of ocular toxicities. However, since MaQ is only available as a powder, it needs suspenssion. Suspension does not always result uniformally, which causes poor visibility. This study reports a new MaQ suspension for better visibility. Methods. After medium addition to a MaQ vial, various methods were used. These included the use of (1 vortex mixer, (2 two syringes and a three-way stopcock, and (3 ultrasonic washer. We calculated suspended MaQ concentration (. To evaluate the reproducibility, we estimated the coefficient of variance (CV, . We used this MaQ for pig eyes, and vitreous visualization was simulated. Subsequently, we used this MaQ suspension for humans. Results. MaQ suspensions were sucessfull, and the concentrations of single particles increased significantly (. The CV was 36.1% for the routine method and 9.03% ffor the new method. Administration of a suspended MaQ made it possible to clearly visualize the vitreous in both pig and human eyes. Conclusions. We devised new techniques for uniformal MaQ suspension. These new methods can compensate for the MaQ disadvantages and ensure a safety surgery.
Discrete method for design of flow distribution in manifolds
International Nuclear Information System (INIS)
Wang, Junye; Wang, Hualin
2015-01-01
Flow in manifold systems is encountered in designs of various industrial processes, such as fuel cells, microreactors, microchannels, plate heat exchanger, and radial flow reactors. The uniformity of flow distribution in manifold is a key indicator for performance of the process equipment. In this paper, a discrete method for a U-type arrangement was developed to evaluate the uniformity of the flow distribution and the pressure drop and then was used for direct comparisons between the U-type and the Z-type. The uniformity of the U-type is generally better than that of the Z-type in most of cases for small ζ and large M. The U-type and the Z-type approach each other as ζ increases or M decreases. However, the Z-type is more sensitive to structures than the U-type and approaches uniform flow distribution faster than the U-type as M decreases or ζ increases. This provides a simple yet powerful tool for the designers to evaluate and select a flow arrangement and offers practical measures for industrial applications. - Highlights: • Discrete methodology of flow field designs in manifolds with U-type arrangements. • Quantitative comparison between U-type and Z-type arrangements. • Discrete solution of flow distribution with varying flow coefficients. • Practical measures and guideline to design of manifold systems.
DEFF Research Database (Denmark)
Sandøy, Helge; Kristiansen, Tore
2010-01-01
1. Comparing empirical findings with the “mountain peak model” In the introduction to this volume, we presented a “mountain peak model” of Nordic purism based on evidence showing that language scholars and lay people are very much in agreement as to where we find the more purist languages......-speaking Finland to Finnish-speaking Finland. In this conclusion to the volume, we will summarize the empirical findings presented in the volume, findings for use and attitudes alike, and compare them with the mountain peak model. That way, we may be able to estimate the nature of the cross-national ideological...
Uniform Single Valued Neutrosophic Graphs
Directory of Open Access Journals (Sweden)
S. Broumi
2017-09-01
Full Text Available In this paper, we propose a new concept named the uniform single valued neutrosophic graph. An illustrative example and some properties are examined. Next, we develop an algorithmic approach for computing the complement of the single valued neutrosophic graph. A numerical example is demonstrated for computing the complement of single valued neutrosophic graphs and uniform single valued neutrosophic graph.
Uniform field loop-gap resonator and rectangular TEU02 for aqueous sample EPR at 94 GHz
Sidabras, Jason W.; Sarna, Tadeusz; Mett, Richard R.; Hyde, James S.
2017-09-01
In this work we present the design and implementation of two uniform-field resonators: a seven-loop-six-gap loop-gap resonator (LGR) and a rectangular TEU02 cavity resonator. Each resonator has uniform-field-producing end-sections. These resonators have been designed for electron paramagnetic resonance (EPR) of aqueous samples at 94 GHz. The LGR geometry employs low-loss Rexolite end-sections to improve the field homogeneity over a 3 mm sample region-of-interest from near-cosine distribution to 90% uniform. The LGR was designed to accommodate large degassable Polytetrafluorethylen (PTFE) tubes (0.81 mm O.D.; 0.25 mm I.D.) for aqueous samples. Additionally, field modulation slots are designed for uniform 100 kHz field modulation incident at the sample. Experiments using a point sample of lithium phthalocyanine (LiPC) were performed to measure both the uniformity of the microwave magnetic field and 100 kHz field modulation, and confirm simulations. The rectangular TEU02 cavity resonator employs over-sized end-sections with sample shielding to provide an 87% uniform field for a 0.1 × 2 × 6 mm3 sample geometry. An evanescent slotted window was designed for light access to irradiate 90% of the sample volume. A novel dual-slot iris was used to minimize microwave magnetic field perturbations and maintain cross-sectional uniformity. Practical EPR experiments using the application of light irradiated rose bengal (4,5,6,7-tetrachloro-2‧,4‧,5‧,7‧-tetraiodofluorescein) were performed in the TEU02 cavity. The implementation of these geometries providing a practical designs for uniform field resonators that continue resonator advancements towards quantitative EPR spectroscopy.
Springett, J. C.
1982-01-01
The technique outlined in this paper is intended to eliminate the problems of cochannel interference and uniform geographic distribution of user channels which arise in conventional designs for a multiple spot beam communication satellite to serve mobile telephony users across the CONUS. By time multiplexing FM/FDMA signal ensembles so that only those beams operating on distinct frequency subbands are allowed to transmit concurrently, cochannel interference arising from simultaneous frequency subband reuse is precluded. Thus, time disjoint frequency reuse is accomplished over a repetitive sequence of fixed time slots. By assigning different size subbands to each time slot, a market of nonuniform users can be accommodated. The technique results in a greatly simplified antenna feed system design for the satellite, at a cost of imposing the need for time slot synchronization on the mobile FM receivers whose ability for rejecting adjacent channel interference is somewhat diminished.
Springett, J. C.
The technique outlined in this paper is intended to eliminate the problems of cochannel interference and uniform geographic distribution of user channels which arise in conventional designs for a multiple spot beam communication satellite to serve mobile telephony users across the CONUS. By time multiplexing FM/FDMA signal ensembles so that only those beams operating on distinct frequency subbands are allowed to transmit concurrently, cochannel interference arising from simultaneous frequency subband reuse is precluded. Thus, time disjoint frequency reuse is accomplished over a repetitive sequence of fixed time slots. By assigning different size subbands to each time slot, a market of nonuniform users can be accommodated. The technique results in a greatly simplified antenna feed system design for the satellite, at a cost of imposing the need for time slot synchronization on the mobile FM receivers whose ability for rejecting adjacent channel interference is somewhat diminished.
Energy Technology Data Exchange (ETDEWEB)
Nikitin, V I
1961-07-01
In this chapter of book are present conclusions about work done by author, in particular that he found comparatively simple and available ways of synthesis of glycerin of acetylene line and glycerin of ethylen line which before was unknown or almost unknown in the chemical literature.
Dynamic thermoelectricity in uniform bipolar semiconductor
Energy Technology Data Exchange (ETDEWEB)
Volovichev, I.N., E-mail: vin@ire.kharkov.ua
2016-07-01
The theory of the dynamic thermoelectric effect has been developed. The effect lies in an electric current flowing in a closed circuit that consists of a uniform bipolar semiconductor, in which a non-uniform temperature distribution in the form of the traveling wave is created. The calculations are performed for the one-dimensional model in the quasi-neutrality approximation. It was shown that the direct thermoelectric current prevails, despite the periodicity of the thermal excitation, the circuit homogeneity and the lack of rectifier properties of the semiconductor system. Several physical reasons underlining the dynamic thermoelectric effect are found. One of them is similar to the Dember photoelectric effect, its contribution to the current flowing is determined by the difference in the electron and hole mobilities, and is completely independent of the carrier Seebeck coefficients. The dependence of the thermoelectric short circuit current magnitude on the semiconductor parameters, as well as on the temperature wave amplitude, length and velocity is studied. It is shown that the magnitude of the thermoelectric current is proportional to the square of the temperature wave amplitude. The dependence of the thermoelectric short circuit current on the temperature wave length and velocity is the nonmonotonic function. The optimum values for the temperature wave length and velocity, at which the dynamic thermoelectric effect is the greatest, have been deduced. It is found that the thermoelectric short circuit current changes its direction with decreasing the temperature wave length under certain conditions. The prospects for the possible applications of the dynamic thermoelectric effect are also discussed.
International Nuclear Information System (INIS)
Yang Min; Li Xiaoping; Xie Kai; Liu Donglin; Liu Yanming
2013-01-01
A large volume uniform plasma generator is proposed for the experiments of electromagnetic (EM) wave propagation in plasma, to reproduce a “black out” phenomenon with long duration in an environment of the ordinary laboratory. The plasma generator achieves a controllable approximate uniform plasma in volume of 260 mm× 260 mm× 180 mm without the magnetic confinement. The plasma is produced by the glow discharge, and the special discharge structure is built to bring a steady approximate uniform plasma environment in the electromagnetic wave propagation path without any other barriers. In addition, the electron density and luminosity distributions of plasma under different discharge conditions were diagnosed and experimentally investigated. Both the electron density and the plasma uniformity are directly proportional to the input power and in roughly reverse proportion to the gas pressure in the chamber. Furthermore, the experiments of electromagnetic wave propagation in plasma are conducted in this plasma generator. Blackout phenomena at GPS signal are observed under this system and the measured attenuation curve is of reasonable agreement with the theoretical one, which suggests the effectiveness of the proposed method.
Dulin, Charles Dewitt
2016-01-01
The purpose of this research is to evaluate the impact of uniform dress codes on a school's climate for student behavior and learning in four middle schools in North Carolina. The research will compare the perceptions of parents, teachers, and administrators in schools with uniform dress codes against schools without uniform dress codes. This…
International Nuclear Information System (INIS)
Hajmohammadi, M.R.; Poozesh, S.; Rahmani, M.; Campo, A.
2013-01-01
This paper explores the bearing that a non-uniform distribution of heat flux used as a wall boundary condition exerts on the heat transfer improvement in a round pipe. Because the overall heat load is considered fixed, the heat transfer improvement is viewed through a reduction in the maximum temperature (‘hot spot’) by imposing optimal distribution of heat flux. Two cases are studied in detail 1) fully developed and 2) developing flow. Peak temperatures in the heated pipe wall are calculated via an analytical approach for the fully developed case, while a numerical simulation based on CFD is employed for the developing case. By relaxing the heat flux distribution on the pipe wall, the numerical results imply that the optimum distribution of heat flux, which minimizes the peak temperatures corresponds with the ‘descending’ distribution. Given that the foregoing approach is quite different from the ‘ascending’ heat flux distribution recommended in the literature by means of the entropy generation minimization (EGM) method, it is inferred that the optimization of heat transfer and fluid flow, in comparison with the thermodynamic optimization, may bring forth quite different guidelines for the designs of thermal systems under the same constraints and circumstances. -- Highlights: • Considered the bearing of non-uniform distribution of heat flux on the hot spots. • Determined the optimal distribution of heat flux that minimizes the hot spots. • Results are compared with those obtained by EGM method
Energy Technology Data Exchange (ETDEWEB)
Sadeghi-Goughari, Moslem [Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Hosseini, Mohammad [Sirjan University of Technology, Sirjan (Iran, Islamic Republic of)
2015-02-15
The vibrational behavior of a viscous nanoflow-conveying single-walled carbon nanotube (SWCNT) was investigated. The nonuniformity of the flow velocity distribution caused by the viscosity of fluid and the small-size effects on the flow field was considered. Euler-Bernoulli beam model was used to investigate flow-induced vibration of the nanotube, while the non-uniformity of the flow velocity and the small-size effects of the flow field were formulated through Knudsen number (Kn), as a discriminant parameter. For laminar flow in a circular nanotube, the momentum correction factor was developed as a function of Kn. For Kn = 0 (continuum flow), the momentum correction factor was found to be 1.33, which decreases by the increase in Kn may even reach near 1 for the transition flow regime. We observed that for passage of viscous flow through a nanotube with the non-uniform flow velocity, the critical continuum flow velocity for divergence decreased considerably as opposed to those for the uniform flow velocity, while by increasing Kn, the difference between the uniform and non-uniform flow models may be reduced. In the solution part, the differential transformation method (DTM) was used to solve the governing differential equations of motion.
International Nuclear Information System (INIS)
Sadeghi-Goughari, Moslem; Hosseini, Mohammad
2015-01-01
The vibrational behavior of a viscous nanoflow-conveying single-walled carbon nanotube (SWCNT) was investigated. The nonuniformity of the flow velocity distribution caused by the viscosity of fluid and the small-size effects on the flow field was considered. Euler-Bernoulli beam model was used to investigate flow-induced vibration of the nanotube, while the non-uniformity of the flow velocity and the small-size effects of the flow field were formulated through Knudsen number (Kn), as a discriminant parameter. For laminar flow in a circular nanotube, the momentum correction factor was developed as a function of Kn. For Kn = 0 (continuum flow), the momentum correction factor was found to be 1.33, which decreases by the increase in Kn may even reach near 1 for the transition flow regime. We observed that for passage of viscous flow through a nanotube with the non-uniform flow velocity, the critical continuum flow velocity for divergence decreased considerably as opposed to those for the uniform flow velocity, while by increasing Kn, the difference between the uniform and non-uniform flow models may be reduced. In the solution part, the differential transformation method (DTM) was used to solve the governing differential equations of motion.
Temperature distributions of a conductively heated filament
International Nuclear Information System (INIS)
Tamura, Koji; Ohba, Hironori; Shibata, Takemasa
1999-07-01
Temperature distributions of a heated filament were measured. A W-Re(5%) filament (0.25 mm in diameter, 24.7 mm in length) was conductively heated by currents between 5A and 7A with a DC power supply, and the surface of the filament was imaged with a charge coupled device (CCD) camera through a monochromatic filter. The spectral radiation intensity at the filament center region was almost uniform. Since the temperature distribution was also uniform and the energy loss by thermal conduction was negligible, temperature in this region was determined from the energy balance between applied power and radiation loss. Temperature distribution of the filament was determined based on the Planck's law of radiation from the spectral radiation intensity ratio of the filament surface using obtained temperature as a reference. It was found that temperature distribution of a filament was easily measured by this method. (author)
Uniform hexagonal graphene flakes and films grown on liquid copper surface.
Geng, Dechao; Wu, Bin; Guo, Yunlong; Huang, Liping; Xue, Yunzhou; Chen, Jianyi; Yu, Gui; Jiang, Lang; Hu, Wenping; Liu, Yunqi
2012-05-22
Unresolved problems associated with the production of graphene materials include the need for greater control over layer number, crystallinity, size, edge structure and spatial orientation, and a better understanding of the underlying mechanisms. Here we report a chemical vapor deposition approach that allows the direct synthesis of uniform single-layered, large-size (up to 10,000 μm(2)), spatially self-aligned, and single-crystalline hexagonal graphene flakes (HGFs) and their continuous films on liquid Cu surfaces. Employing a liquid Cu surface completely eliminates the grain boundaries in solid polycrystalline Cu, resulting in a uniform nucleation distribution and low graphene nucleation density, but also enables self-assembly of HGFs into compact and ordered structures. These HGFs show an average two-dimensional resistivity of 609 ± 200 Ω and saturation current density of 0.96 ± 0.15 mA/μm, demonstrating their good conductivity and capability for carrying high current density.
Fumigant distribution in forest nursery soils
Dong Wang; Stephen W. Fraedrich; Jennifer Juzwik; Kurt Spokas; Yi Zhang; William C. Koskinen
2006-01-01
Adequate concentration, exposure time and distribution uniformity of activated fumigant gases are prerequisites for successful soil fumigation. Field experiments were conducted to evaluate gas phase distributions of methyl isothiocyanate (MITC) and chloropicrin (CP) in two forest-tree nurseries. Concentrations of MITC and CP in soil air were measured from replicated...
A Uniform Syntax and Discourse Structure
DEFF Research Database (Denmark)
Hardt, Daniel
2013-01-01
I present arguments in favor of the Uniformity Hypothesis: the hypothesis that discourse can extend syntax dependencies without conflicting with them. I consider arguments that Uniformity is violated in certain cases involving quotation, and I argue that the cases presented in the literature...
Aging transition in systems of oscillators with global distributed-delay coupling.
Rahman, B; Blyuss, K B; Kyrychko, Y N
2017-09-01
We consider a globally coupled network of active (oscillatory) and inactive (nonoscillatory) oscillators with distributed-delay coupling. Conditions for aging transition, associated with suppression of oscillations, are derived for uniform and gamma delay distributions in terms of coupling parameters and the proportion of inactive oscillators. The results suggest that for the uniform distribution increasing the width of distribution for the same mean delay allows aging transition to happen for a smaller coupling strength and a smaller proportion of inactive elements. For gamma distribution with sufficiently large mean time delay, it may be possible to achieve aging transition for an arbitrary proportion of inactive oscillators, as long as the coupling strength lies in a certain range.
Non-uniform dispersion of the source-sink relationship alters wavefront curvature.
Directory of Open Access Journals (Sweden)
Lucia Romero
Full Text Available The distribution of cellular source-sink relationships plays an important role in cardiac propagation. It can lead to conduction slowing and block as well as wave fractionation. It is of great interest to unravel the mechanisms underlying evolution in wavefront geometry. Our goal is to investigate the role of the source-sink relationship on wavefront geometry using computer simulations. We analyzed the role of variability in the microscopic source-sink relationship in driving changes in wavefront geometry. The electrophysiological activity of a homogeneous isotropic tissue was simulated using the ten Tusscher and Panfilov 2006 action potential model and the source-sink relationship was characterized using an improved version of the Romero et al. safety factor formulation (SFm2. Our simulations reveal that non-uniform dispersion of the cellular source-sink relationship (dispersion along the wavefront leads to alterations in curvature. To better understand the role of the source-sink relationship in the process of wave formation, the electrophysiological activity at the initiation of excitation waves in a 1D strand was examined and the source-sink relationship was characterized using the two recently updated safety factor formulations: the SFm2 and the Boyle-Vigmond (SFVB definitions. The electrophysiological activity at the initiation of excitation waves was intimately related to the SFm2 profiles, while the SFVB led to several counterintuitive observations. Importantly, with the SFm2 characterization, a critical source-sink relationship for initiation of excitation waves was identified, which was independent of the size of the electrode of excitation, membrane excitability, or tissue conductivity. In conclusion, our work suggests that non-uniform dispersion of the source-sink relationship alters wavefront curvature and a critical source-sink relationship profile separates wave expansion from collapse. Our study reinforces the idea that the
Private Uniform Contamination Used by Nursing Staff in Intensive Care Units.
Directory of Open Access Journals (Sweden)
Bruno Dos Santos Valadares
2017-01-01
Full Text Available Background and Objectives: The study aimed to verify the presence of pathogens in private uniform professionals with access to the Intensive Care Unit (ICU and analyze the sensitivity profile of the samples positive for Staphylococcus aureus. Methods: Samples were collected before and after the work day and later performed microbiological analyzes. Results: There was a percentage change in the total growth of 154%, with a predominance of coagulase-negative Staphylococcus (72.8% followed by Staphylococcus aureus (38.4%. The latter showed considerable resistance to some specific antibiotic used for treatment. Conclusions: In this study it was possible to identify the presence of various potentially pathogenic micro-organisms in private uniform used by professionals in the ICU, verifying that the colonization of these bacteria has a progressive increase over the use of time. Strains of Staphylococcus aureus tested against the antimicrobial had a high profile susceptibility to drugs such as vancomycin and medium to oxacillin. With the large number of infections caused by bacteria resistant to different antibiotics, one should not rule out any possible means of dissemination of these microorganisms. However, more studies should be developed so that there is a confirmation that the bacteria found on the uniforms are the same that cause IRHs. KEYWORDS: Contamination. Protective clothing. Cross Infection. Intensive care unit.
Directory of Open Access Journals (Sweden)
Nguyen Xuan Tien
2016-09-01
Full Text Available This paper proposes a novel concentrator photovoltaic (CPV system with improved irradiation uniformity and system efficiency. CPV technology is very promising its for highly efficient solar energy conversion. A conventional CPV system usually uses only one optical component, such as a refractive Fresnel lens or a reflective parabolic dish, to collect and concentrate solar radiation on the solar cell surface. Such a system creates strongly non-uniform irradiation distribution on the solar cell, which tends to cause hot spots, current mismatch, and degrades the overall efficiency of the system. Additionally, a high-concentration CPV system is unable to collect diffuse solar radiation. In this paper, we propose a novel CPV system with improved irradiation uniformity and collection of diffuse solar radiation. The proposed system uses a Fresnel lens as a primary optical element (POE to concentrate and focus the sunlight and a plano-concave lens as a secondary optical element (SOE to uniformly distribute the sunlight over the surface of multi-junction (MJ solar cells. By using the SOE, the irradiance uniformity is significantly improved in the system. Additionally, the proposed system also captures diffuse solar radiation by using an additional low-cost solar cell surrounding MJ cells. In our system, incident direct solar radiation is captured by MJ solar cells, whereas incident diffuse solar radiation is captured by the low-cost solar cell. Simulation models were developed using a commercial optical simulation tool (LightTools™. The irradiance uniformity and efficiency of the proposed CPV system were analyzed, evaluated, and compared with those of conventional CPV systems. The analyzed and simulated results show that the CPV system significantly improves the irradiance uniformity as well as the system efficiency compared to the conventional CPV systems. Numerically, for our simulation models, the designed CPV with the SOE and low-cost cell provided
DEFF Research Database (Denmark)
Kohlenbach, Ulrich
2002-01-01
The so-called weak Konig's lemma WKL asserts the existence of an infinite path b in any infinite binary tree (given by a representing function f). Based on this principle one can formulate subsystems of higher-order arithmetic which allow to carry out very substantial parts of classical mathematics...... which-relative to PRA -implies the schema of 10-induction). In this setting one can consider also a uniform version UWKL of WKL which asserts the existence of a functional which selects uniformly in a given infinite binary tree f an infinite path f of that tree. This uniform version of WKL...
RELIABLE COGNITIVE DIMENSIONAL DOCUMENT RANKING BY WEIGHTED STANDARD CAUCHY DISTRIBUTION
Directory of Open Access Journals (Sweden)
S Florence Vijila
2017-04-01
Full Text Available Categorization of cognitively uniform and consistent documents such as University question papers are in demand by e-learners. Literature indicates that Standard Cauchy distribution and the derived values are extensively used for checking uniformity and consistency of documents. The paper attempts to apply this technique for categorizing question papers according to four selective cognitive dimensions. For this purpose cognitive dimensional keyword sets of these four categories (also termed as portrayal concepts are assumed and an automatic procedure is developed to quantify these dimensions in question papers. The categorization is relatively accurate when checked with manual methods. Hence simple and well established term frequency / inverse document frequency ‘tf/ IDF’ technique is considered for automating the categorization process. After the documents categorization, standard Cauchy formula is applied to rank order the documents that have the least differences among Cauchy value, (according to Cauchy theorem so as obtain consistent and uniform documents in an order or ranked. For the purpose of experiments and social survey, seven question papers (documents have been designed with various consistencies. To validate this proposed technique social survey is administered on selective samples of e-learners of Tamil Nadu, India. Results are encouraging and conclusions drawn out of the experiments will be useful to researchers of concept mining and categorizing documents according to concepts. Findings have also contributed utility value to e-learning system designers.
Cui, J; Lv, Y; Yang, X J; Fan, Y L; Zhong, Z; Jiang, Z M
2011-03-25
The size uniformity of self-assembled SiGe quantum rings, which are formed by capping SiGe quantum dots with a thin Si layer, is found to be greatly influenced by the growth temperature and the areal density of SiGe quantum dots. Higher growth temperature benefits the size uniformity of quantum dots, but results in low Ge concentration as well as asymmetric Ge distribution in the dots, which induces the subsequently formed quantum rings to be asymmetric in shape or even broken somewhere in the ridge of rings. Low growth temperature degrades the size uniformity of quantum dots, and thus that of quantum rings. A high areal density results in the expansion and coalescence of neighboring quantum dots to form a chain, rather than quantum rings. Uniform quantum rings with a size dispersion of 4.6% and an areal density of 7.8×10(8) cm(-2) are obtained at the optimized growth temperature of 640°C.
Vu, Lien T; Chen, Chao-Chang A; Yu, Chia-Wei
2018-02-05
This study aims to develop a new optical design method of soft multifocal contact lens (CLs) to obtain uniform optical power in large center-distance zone with optimized Non-Uniform Rational B-spline (NURBS). For the anterior surface profiles of CLs, the NURBS design curves are optimized to match given optical power distributions. Then, the NURBS in the center-distance zones are fitted in the corresponding spherical/aspheric curves for both data points and their centers of curvature to achieve the uniform power. Four cases of soft CLs have been manufactured by casting in shell molds by injection molding and then measured to verify the design specifications. Results of power profiles of these CLs are concord with the given clinical requirements of uniform powers in larger center-distance zone. The developed optical design method has been verified for multifocal CLs design and can be further applied for production of soft multifocal CLs.
A School Uniform Program That Works.
Loesch, Paul C.
1995-01-01
According to advocates, school uniforms reduce gang influence, decrease families' clothing expenditures, and help mitigate potentially divisive cultural and economic differences. Aiming to improve school climate, a California elementary school adopted uniforms as a source of pride and affiliation. This article describes the development of the…
Uniform, stable supply of medium for in vitro cell culture using a robust chamber
Wei, Juan; Liu, Chong; Jiang, Yang; Liu, Tao; Chen, Li; Liu, Bo; Li, Jingmin
2018-06-01
A uniform, stable supply of medium is important for in vitro cell culture. In this paper, a microfluidic device is presented for culturing cells inside a robust chamber with continuous perfusion of medium. The device consists of a main channel, two bifurcated channels and a culture chamber. The culture chamber connects to the bifurcated channels via multiple paths, and distributes symmetrically on the main channel, to improve the efficiency of medium exchange. Furthermore, regular polygonal chambers with various numbers of edges have been designed, to study the effects of chamber shape on flow fields. The finite element method has been employed to predict the effects of multiple paths on the uniformity and stability of flow fields in the culture chamber. Particle tracking technology has been used to evaluate the flow fields in the chambers, and PC-12 cells have been cultured using the microfluidic device, to test its validity. The results of simulation and experiment indicate that the microfluidic design could provide a continuous interstitial-like flow microenvironment, with a relatively stable and uniform supply of medium.
Nonlinear periodic wavetrains in thin liquid films falling on a uniformly heated horizontal plate
Issokolo, Remi J. Noumana; Dikandé, Alain M.
2018-05-01
A thin liquid film falling on a uniformly heated horizontal plate spreads into fingering ripples that can display a complex dynamics ranging from continuous waves, nonlinear spatially localized periodic wave patterns (i.e., rivulet structures) to modulated nonlinear wavetrain structures. Some of these structures have been observed experimentally; however, conditions under which they form are still not well understood. In this work, we examine profiles of nonlinear wave patterns formed by a thin liquid film falling on a uniformly heated horizontal plate. For this purpose, the Benney model is considered assuming a uniform temperature distribution along the film propagation on the horizontal surface. It is shown that for strong surface tension but a relatively small Biot number, spatially localized periodic-wave structures can be analytically obtained by solving the governing equation under appropriate conditions. In the regime of weak nonlinearity, a multiple-scale expansion combined with the reductive perturbation method leads to a complex Ginzburg-Landau equation: the solutions of which are modulated periodic pulse trains which amplitude and width and period are expressed in terms of characteristic parameters of the model.
Non-uniform Mutation Rates for Problems with Unknown Solution Lengths
DEFF Research Database (Denmark)
Cathabard, Stephan; Lehre, Per Kristian; Yao, Xin
2011-01-01
Many practical optimisation problems allow candidate solu- tions of varying lengths, and where the length of the opti- mal solution is thereby a priori unknown. We suggest that non-uniform mutation rates can be beneficial when solving such problems. In particular, we consider a mutation oper- ator...... that flips each bit with a probability that is inversely proportional to the bit position, rather than the bitstring length. The runtime of the (1+1) EA using this mutation operator is analysed rigorously on standard example func- tions. Furthermore, the behaviour of the new mutation op- erator...... distribution, and show that the new operator can yield exponentially faster runtimes for some parameters of this distribution. The experimental results show that the new mutation operator leads to dramatically shorter runtimes on a class of instances of the software engi- neering problem that is conjectured...
A stability criterion for HNFDE with non-uniform delays
International Nuclear Information System (INIS)
Liu Xingwen; Zhong Shouming; Zhang Fengli
2005-01-01
Stability of functional differential equations (FDE) is an increasingly important problem in both science and engineering. Delays, whether uniform or non-uniform, play an important role in the dynamics of a system. Since non-uniform delay is more general and less focused than uniform delay, this paper concentrates on the stability of high-order neutral functional differential equations (HNFDE) with non-uniform delay, and proposes a sufficient condition for it. This result may be widely helpful, thanks to the frequent emergence of a HNFDE with non-uniform delay in various fields. Its effectiveness is illustrated by some examples
Liouville theory and uniformization of four-punctured sphere
Hadasz, Leszek; Jaskolski, Zbigniew
2006-01-01
Few years ago Zamolodchikov and Zamolodchikov proposed an expression for the 4-point classical Liouville action in terms of the 3-point actions and the classical conformal block. In this paper we develop a method of calculating the uniformizing map and the uniformizing group from the classical Liouville action on n-punctured sphere and discuss the consequences of Zamolodchikovs conjecture for an explicit construction of the uniformizing map and the uniformizing group for the sphere with four ...
School Uniforms and Discourses on Childhood.
Bodine, Ann
2003-01-01
This ethnographic study examined the introduction of school uniforms in the public schools of one California city. Findings indicated that the uniform issue intersected with issues such as student safety and violence, family stress, egalitarianism, competitive dressing, and a power struggle over shaping the childhood environment. It was concluded…
Study of device for precompaction and uniform supply of materials to working bodies of aggregate
Romanovich, A. A.; Kolesnikov, R. S.; Romanovich, M. A.
2018-03-01
The article considers perspective ways of increase of reliability and durability of the press roller grinder due to the uniform supply of crushed materials across the width of the rolls. The mechanism of distribution and pre- compaction of materials in a roller arrangement has been analytically studied, an equation has been derived for calculating the effort expended. The materials of the article are devoted to increasing the reliability of the press roller grinder due to the uniform supply of grindable materials along the width of the rolls and may be of interest to Russian and foreign organizations that carry out their activities in the field of exploitation, designing and manufacturing of crushing and grinding equipment.
An Artificial Neural Network for Analyzing Overall Uniformity in Outdoor Lighting Systems
Directory of Open Access Journals (Sweden)
Antonio del Corte-Valiente
2017-02-01
Full Text Available Street lighting installations are an essential service for modern life due to their capability of creating a welcoming feeling at nighttime. Nevertheless, several studies have highlighted that it is possible to improve the quality of the light significantly improving the uniformity of the illuminance. The main difficulty arises when trying to improve some of the installation’s characteristics based only on statistical analysis of the light distribution. This paper presents a new algorithm that is able to obtain the overall illuminance uniformity in order to improve this sort of installations. To develop this algorithm it was necessary to perform a detailed study of all the elements which are part of street lighting installations. Because classification is one of the most important tasks in the application areas of artificial neural networks, we compared the performances of six types of training algorithms in a feed forward neural network for analyzing the overall uniformity in outdoor lighting systems. We found that the best algorithm that minimizes the error is “Levenberg-Marquardt back-propagation”, which approximates the desired output of the training pattern. By means of this kind of algorithm, it is possible to help to lighting professionals optimize the quality of street lighting installations.
On The Dynamic Analysis of Non-Uniform Beams Under Uniformly ...
African Journals Online (AJOL)
... the non-uniform continuous beam was replaced by a non-continuous (discrete) system made up of beam elements. The modified elemental and overall stiffness, and mass matrices, the elemental and overall centripetal acceleration matrices as well as the load vector were derived. Next, the Newmark's direct integration ...
International Nuclear Information System (INIS)
Szoke, Istvan; Balashazy, Imre; Farkas, Arpad; Hofmann, Werner
2007-01-01
The human tracheobronchial system has a very complex structure including cylindrical airway ducts connected by airway bifurcation units. The deposition of the inhaled aerosols within the airways exhibits a very inhomogeneous pattern. The formation of deposition hot spots near the carinal ridge has been confirmed by experimental and computational fluid and particle dynamics (CFPD) methods. In spite of these observations, current radon lung dosimetry models apply infinitely long cylinders as models of the airway system and assume uniform deposition of the inhaled radon progenies along the airway walls. The aim of this study is to investigate the effect of airway geometry and non-uniform activity distributions within bronchial bifurcations on cellular dose distributions. In order to answer these questions, the nuclear doses of the bronchial epithelium were calculated in three different irradiation situations. (1) First, CFPD methods were applied to calculate the distribution of the deposited alpha-emitting nuclides in a numerically constructed idealized airway bifurcation. (2) Second, the deposited radionuclides were randomly distributed along the surface of the above-mentioned geometry. (3) Finally, calculations were made in cylindrical geometries corresponding to the parent and daughter branches of the bifurcation geometry assuming random nuclide activity distribution. In all three models, the same 218 Po and 214 Po surface activities per tissue volumes were assumed. Two conclusions can be drawn from this analysis: (i) average nuclear doses are very similar in all three cases (minor differences can be attributed to differences in the linear energy transfer (LET) spectra) and (ii) dose distributions are significantly different in all three cases, with the highest doses at the carinal ridge in case 3. (authors)
Scale-free behavior of networks with the copresence of preferential and uniform attachment rules
Pachon, Angelica; Sacerdote, Laura; Yang, Shuyi
2018-05-01
Complex networks in different areas exhibit degree distributions with a heavy upper tail. A preferential attachment mechanism in a growth process produces a graph with this feature. We herein investigate a variant of the simple preferential attachment model, whose modifications are interesting for two main reasons: to analyze more realistic models and to study the robustness of the scale-free behavior of the degree distribution. We introduce and study a model which takes into account two different attachment rules: a preferential attachment mechanism (with probability 1 - p) that stresses the rich get richer system, and a uniform choice (with probability p) for the most recent nodes, i.e. the nodes belonging to a window of size w to the left of the last born node. The latter highlights a trend to select one of the last added nodes when no information is available. The recent nodes can be either a given fixed number or a proportion (αn) of the total number of existing nodes. In the first case, we prove that this model exhibits an asymptotically power-law degree distribution. The same result is then illustrated through simulations in the second case. When the window of recent nodes has a constant size, we herein prove that the presence of the uniform rule delays the starting time from which the asymptotic regime starts to hold. The mean number of nodes of degree k and the asymptotic degree distribution are also determined analytically. Finally, a sensitivity analysis on the parameters of the model is performed.
Philosophy, design and testing of a uniform applied load flat plate testing machine
International Nuclear Information System (INIS)
Quirk, A.; Crook, C.
1976-08-01
The presence of a central crack, and its associated plastic zones may significantly affect distribution of the stress applied by a loading machine, to a test plate. As a result the fracture stress may be affected, usually optimistically. Examples of these effects are discussed. The design of a machine in which the load is uniformly applied to the test specimen is described and preliminary test data presented. (author)
An Assessment of the Uniform Funding Policy of DoD Directive 3200.11.
1980-09-01
34 Unpublished master’s thesis. GSM/SM/73-10, AFIT/EN, Wright-Patterson AFB OH 45433, 7 January 1974. Horngren , Charles T. Cost Accounting : A Management...reverse side if noceeeary aid identify by block number) Uniform Funding Policy Test Facilities Test and Evaluation Cost Accounting Accounting 20...segregated from overhead as a cost accounting device in both Government and industry. Historically, this distinc- tion has merely aided distribution of total
Current use of medical eponyms – a need for global uniformity in scientific publications
Directory of Open Access Journals (Sweden)
Arora Nalini
2009-03-01
Full Text Available Abstract Background Although eponyms are widely used in medicine, they arbitrarily alternate between the possessive and nonpossessive forms. As very little is known regarding extent and distribution of this variation, the present study was planned to assess current use of eponymous term taking "Down syndrome" and "Down's syndrome" as an example. Methods This study was carried out in two phases – first phase in 1998 and second phase in 2008. In the first phase, we manually searched the terms "Down syndrome" and "Down's syndrome" in the indexes of 70 medical books, and 46 medical journals. In second phase, we performed PubMed search with both the terms, followed by text-word search for the same. Results In the first phase, there was an overall tilt towards possessive form – 62(53.4% "Down's syndrome" versus 54(46.6% "Down syndrome." However, the American publications preferred the nonpossesive form when compared with their European counterpart (40/50 versus 14/66; P Conclusion Inconsistency in the use of medical eponyms remains a major problem in literature search. Because of linguistic simplicity and technical advantages, the nonpossessive form should be used uniformly worldwide.
Uniform topology on EQ-algebras
Directory of Open Access Journals (Sweden)
Yang Jiang
2017-04-01
Full Text Available In this paper, we use filters of an EQ-algebra E to induce a uniform structure (E, , and then the part induce a uniform topology in E. We prove that the pair (E, is a topological EQ-algebra, and some properties of (E, are investigated. In particular, we show that (E, is a first-countable, zero-dimensional, disconnected and completely regular space. Finally, by using convergence of nets, the convergence of topological EQ-algebras is obtained.
Non-uniform versus uniform attenuation correction in brain perfusion SPET of healthy volunteers
International Nuclear Information System (INIS)
Van Laere, K.; Versijpt, J.; Dierckx, R.; Koole, M.
2001-01-01
Although non-uniform attenuation correction (NUAC) can supply more accurate absolute quantification, it is not entirely clear whether NUAC provides clear-cut benefits in the routine clinical practice of brain SPET imaging. The aim of this study was to compare the effect of NUAC versus uniform attenuation correction (UAC) on volume of interest (VOI)-based semi-quantification of a large age- and gender-stratified brain perfusion normal database. Eighty-nine healthy volunteers (46 females and 43 males, aged 20-81 years) underwent standardised high-resolution single-photon emission tomography (SPET) with 925 MBq 99m Tc-ethyl cysteinate dimer (ECD) on a Toshiba GCA-9300A camera with 153 Gd or 99m Tc transmission CT scanning. Emission images were reconstructed by filtered back-projection and scatter corrected using the triple-energy window correction method. Both non-uniform Chang attenuation correction (one iteration) and uniform Sorenson correction (attenuation coefficient 0.09 cm -1 ) were applied. Images were automatically re-oriented to a stereotactic template on which 35 predefined VOIs were defined for semi-quantification (normalisation on total VOI counts). Small but significant differences between relative VOI uptake values for NUAC versus UAC in the infratentorial region were found. VOI standard deviations were significantly smaller for UAC, 4.5% (range 2.6-7.5), than for NUAC, 5.0% (2.3-9.0) (P 99m Tc-ECD uptake values in healthy volunteers to those obtained with NUAC, although values for the infratentorial region are slightly lower. NUAC produces a slight increase in inter-subject variability. Further study is necessary in various patient populations to establish the full clinical impact of NUAC in brain perfusion SPET. (orig.)
Yuan, Cheng-song; Chen, Wan; Chen, Chen; Yang, Guang-hua; Hu, Chao; Tang, Kang-lai
2015-01-01
We investigated the effects on subtalar joint stress distribution after cannulated screw insertion at different positions and directions. After establishing a 3-dimensional geometric model of a normal subtalar joint, we analyzed the most ideal cannulated screw insertion position and approach for subtalar joint stress distribution and compared the differences in loading stress, antirotary strength, and anti-inversion/eversion strength among lateral-medial antiparallel screw insertion, traditional screw insertion, and ideal cannulated screw insertion. The screw insertion approach allowing the most uniform subtalar joint loading stress distribution was lateral screw insertion near the border of the talar neck plus medial screw insertion close to the ankle joint. For stress distribution uniformity, antirotary strength, and anti-inversion/eversion strength, lateral-medial antiparallel screw insertion was superior to traditional double-screw insertion. Compared with ideal cannulated screw insertion, slightly poorer stress distribution uniformity and better antirotary strength and anti-inversion/eversion strength were observed for lateral-medial antiparallel screw insertion. Traditional single-screw insertion was better than double-screw insertion for stress distribution uniformity but worse for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion was slightly worse for stress distribution uniformity than was ideal cannulated screw insertion but superior to traditional screw insertion. It was better than both ideal cannulated screw insertion and traditional screw insertion for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion is an approach with simple localization, convenient operation, and good safety. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Liouville theory and uniformization of four-punctured sphere
Hadasz, Leszek; Jaskólski, Zbigniew
2006-08-01
A few years ago Zamolodchikov and Zamolodchikov proposed an expression for the four-point classical Liouville action in terms of the three-point actions and the classical conformal block [Nucl. Phys. B 477, 577 (1996)]. In this paper we develop a method of calculating the uniformizing map and the uniformizing group from the classical Liouville action on n-punctured sphere and discuss the consequences of Zamolodchikovs conjecture for an explicit construction of the uniformizing map and the uniformizing group for the sphere with four punctures.
Green Design and Sustainable Development of School Uniforms
Cui, Yumei; Fang, Xuemeng; Zhou, Honglei
2018-01-01
Since the 1990s, the school uniform has gradually become an integral part of campus culture construction. A school uniform is not only an iconic symbol of students and a school, but also the carrier of campus culture, with special education function and cultural connotation. However in the same time, many problems exist in the design, making and material selection of school uniforms, in which, substandard fabric quality is the most serious problem. To ensure the quality, health and safety of school uniforms, in my opinion, priority should be given to green design and sustainable development in the design process of school uniforms, which will be more conducive to promoting the sound development of school uniforms. In today’s economic development, the globalization of mass production is no longer just a symbol of challenging the limits of human beings, but to explore the unlimited potential of human spiritual collaboration. If we want to have a better future on this planet, we need to completely redefine the key issue we need to address, that is, green design. The rise of green products is a great progress of human understanding and solving environmental problems. It is the inevitable development trend of commodity production, and will have a profound impact on human survival and development in the future. School uniform is an important part of campus culture construction. In order to not damage the health of primary and secondary school students, in the school uniform design and production process should follow the concept of “green design” to achieve the school uniform style, color, material design, a comprehensive “green” positioning.
Conclusions and recommendations
International Nuclear Information System (INIS)
1984-01-01
The FAO/IAEA/GSF/SIDA Co-ordinated Research Programme on Cereal Grain Protein Improvement by Nuclear Techniques was a follow-up to the FAO/IAEA/GSF Co-ordinated Research Programme on the Use of Nuclear Techniques for Seed Protein Improvement. It was initiated in 1969 and ended in 1981. The objectives of the meeting were to review and evaluate the achievements of the current and previous programmes in order to draw conclusions on the possibility of genetic improvement of cereal grain protein using nuclear techniques, to identify unsolved problems and to discuss and propose possible approaches for their solution. Through reviews and discussions, conclusions and recommendations were made by the participants
Dose sculpting with generalized equivalent uniform dose
International Nuclear Information System (INIS)
Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan
2005-01-01
With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to
High-uniformity centimeter-wide Si etching method for MEMS devices with large opening elements
Okamoto, Yuki; Tohyama, Yukiya; Inagaki, Shunsuke; Takiguchi, Mikio; Ono, Tomoki; Lebrasseur, Eric; Mita, Yoshio
2018-04-01
We propose a compensated mesh pattern filling method to achieve highly uniform wafer depth etching (over hundreds of microns) with a large-area opening (over centimeter). The mesh opening diameter is gradually changed between the center and the edge of a large etching area. Using such a design, the etching depth distribution depending on sidewall distance (known as the local loading effect) inversely compensates for the over-centimeter-scale etching depth distribution, known as the global or within-die(chip)-scale loading effect. Only a single DRIE with test structure patterns provides a micro-electromechanical systems (MEMS) designer with the etched depth dependence on the mesh opening size as well as on the distance from the chip edge, and the designer only has to set the opening size so as to obtain a uniform etching depth over the entire chip. This method is useful when process optimization cannot be performed, such as in the cases of using standard conditions for a foundry service and of short turn-around-time prototyping. To demonstrate, a large MEMS mirror that needed over 1 cm2 of backside etching was successfully fabricated using as-is-provided DRIE conditions.
Uniform approximation is more appropriate for Wilcoxon Rank-Sum Test in gene set analysis.
Directory of Open Access Journals (Sweden)
Zhide Fang
Full Text Available Gene set analysis is widely used to facilitate biological interpretations in the analyses of differential expression from high throughput profiling data. Wilcoxon Rank-Sum (WRS test is one of the commonly used methods in gene set enrichment analysis. It compares the ranks of genes in a gene set against those of genes outside the gene set. This method is easy to implement and it eliminates the dichotomization of genes into significant and non-significant in a competitive hypothesis testing. Due to the large number of genes being examined, it is impractical to calculate the exact null distribution for the WRS test. Therefore, the normal distribution is commonly used as an approximation. However, as we demonstrate in this paper, the normal approximation is problematic when a gene set with relative small number of genes is tested against the large number of genes in the complementary set. In this situation, a uniform approximation is substantially more powerful, more accurate, and less intensive in computation. We demonstrate the advantage of the uniform approximations in Gene Ontology (GO term analysis using simulations and real data sets.
DEFF Research Database (Denmark)
Jørgensen, Christian Helms; Wallo, Andreas; Toiviainen, Hanna
2015-01-01
Work in times of globalisation and uncertainty is undergoing considerable changes, which has strengthened the importance of work as a site of learning. New trends in production, such as digitalisation, challenge traditional modes of producing goods and services. Emerging forms of flexible...... production and knowledge-work offer growing learning opportunities to people throughout their active working life. In contrast to the stable and standardised modes of Fordist production, modern working life is characterised by rapid changes and employees interacting across globally distributed professional...... explores the challenges of working and learning on the boundaries between education and working life. Globalisation affects the transition patterns from vocational education to the labour market in many ways (Schoon & Silbereisen, 2009), even though the specific challenges to national-level policies vary...
Hameren, Andreas Ferdinand Willem van
2001-01-01
Discrepancies play an important role in the study of uniformity properties of point sets. Their probability distributions are a help in the analysis of the efficiency of the Quasi Monte Carlo method of numerical integration, which uses point sets that are distributed more uniformly than sets of
Directory of Open Access Journals (Sweden)
Jeom Kee Paik
2012-01-01
Full Text Available The Galerkin method is applied to analyze the elastic large deflection behavior of metal plates subject to a combination of in-plane loads such as biaxial loads, edge shear and biaxial inplane bending moments, and uniformly or nonuniformly distributed lateral pressure loads. The motive of the present study was initiated by the fact that metal plates of ships and ship-shaped offshore structures at sea are often subjected to non-uniformly distributed lateral pressure loads arising from cargo or water pressure, together with inplane axial loads or inplane bending moments, but the current practice of the maritime industry usually applies some simplified design methods assuming that the non-uniform pressure distribution in the plates can be replaced by an equivalence of uniform pressure distribution. Applied examples are presented, demonstrating that the current plate design methods of the maritime industry may be inappropriate when the non-uniformity of lateral pressure loads becomes more significant.
The effect of Au amount on size uniformity of self-assembled Au nanoparticles
Energy Technology Data Exchange (ETDEWEB)
Chen, S-H; Wang, D-C; Chen, G-Y; Chen, K-Y [Graduate School of Engineering Science and Technology, National Yunlin University of Science and Technology, Taiwan (China)
2008-03-15
The self-assembled fabrication of nanostructure, a dreaming approach in the area of fabrication engineering, is the ultimate goal of this research. A finding was proved through previous research that the size of the self-assembled gold nanoparticles could be controlled with the mole ratio between AuCl{sub 4}{sup -} and thiol. In this study, the moles of Au were fixed, only the moles of thiol were adjusted. Five different mole ratios of Au/S with their effect on size uniformity were investigated. The mole ratios were 1:1/16, 1:1/8, 1:1, 1:8, 1:16, respectively. The size distributions of the gold nanoparticles were analyzed by Mac-View analysis software. HR-TEM was used to derive images of self-assembled gold nanoparticles. The result reached was also the higher the mole ratio between AuCl{sub 4}{sup -} and thiol the bigger the self-assembled gold nanoparticles. Under the condition of moles of Au fixed, the most homogeneous nanoparticles in size distribution derived with the mole ratio of 1:1/8 between AuCl{sub 4}{sup -} and thiol. The obtained nanoparticles could be used, for example, in uniform surface nanofabrication, leading to the fabrication of ordered array of quantum dots.
The influence of density distribution on the stability of beams
International Nuclear Information System (INIS)
Guy, F.W.; Lapostolle, P.M.; Wangler, T.P.
1987-01-01
We examine the effect of various density distributions in four-dimensional phase space and their projections in real and velocity space on the stability of continuous beams in alternating-gradient transport lines using particle-following computer simulations. We discuss the susceptibility of three different distributions (Kapchinskii-Vladimirskii, bicylinder, and thermal) to third- and higher-order mode instabilities. These distributions are all uniform in real space, but their velocity distributions are different; they also react differently to structure resonances. Velocity distributions of high-current beams tend to evolve to a peaked Gaussian-like form. Is there a specific velocity distribution that is stable and, therefore, the preferred injection distribution for minimizing emittance growth? Forced smoothness or uniformity in real space is necessary for setting up particle simulations of high-current beams so that spurious charge-redistribution emittance growth can be avoided. Is forced smoothness also desirable in four dimensions for continuous beams and possibly in six dimensions for bunched beams? We consider these and related questions
A new correlation of non-uniformly heated round tube burnout data
International Nuclear Information System (INIS)
Kirby, G.J.
1966-07-01
A new correlation of non-uniformly heated round tube burnout data is presented. This fits the available data better than any previously published correlation - the root-mean-square deviation being 5.7% for all data at 1000 p.s.i.a. and the worst fit being to data at 2000 p.s.i.a. where the r.m.s. error is 6.6%. The correlation is used to investigate the effect of flux profile changes and no significant increase in burnout power is obtained by modifying the present chopped cosine distribution. (author)
Evaluation of concave dose distributions created using an inverse planning system
International Nuclear Information System (INIS)
Hunt, Margie A.; Hsiung, C.-Y.; Spirou, Spirodon V.; Chui, C.-S.; Amols, Howard I.; Ling, Clifton C.
2002-01-01
Purpose: To evaluate and develop optimum inverse treatment planning strategies for the treatment of concave targets adjacent to normal tissue structures. Methods and Materials: Optimized dose distributions were designed using an idealized geometry consisting of a cylindrical phantom with a concave kidney-shaped target (PTV) and cylindrical normal tissues (NT) placed 5-13 mm from the target. Targets with radii of curvature from 1 to 2.75 cm were paired with normal tissues with radii between 0.5 and 2.25 cm. The target was constrained to a prescription dose of 100% and minimum and maximum doses of 95% and 105% with relative penalties of 25. Maximum dose constraint parameters for the NT varied from 10% to 70% with penalties from 10 to 1000. Plans were evaluated using the PTV uniformity index (PTV D max /PTV D 95 ) and maximum normal tissue doses (NT D max /PTV D 95 ). Results: In nearly all situations, the achievable PTV uniformity index and the maximum NT dose exceeded the corresponding constraints. This was particularly true for small PTV-NT separations (5-8 mm) or strict NT dose constraints (10%-30%), where the achievable doses differed from the requested by 30% or more. The same constraint parameters applied to different PTV-NT separations yielded different dose distributions. For most geometries, a range of constraints could be identified that would lead to acceptable plans. The optimization results were fairly independent of beam energy and radius of curvature, but improved as the number of beams increased, particularly for small PTV-NT separations or strict dose constraints. Conclusion: Optimized dose distributions are strongly affected by both the constraint parameters and target-normal tissue geometry. Standard site-specific constraint templates can serve as a starting point for optimization, but the final constraints must be determined iteratively for individual patients. A strategy whereby NT constraints and penalties are modified until the highest
Highly Uniform Carbon Nanotube Field-Effect Transistors and Medium Scale Integrated Circuits.
Chen, Bingyan; Zhang, Panpan; Ding, Li; Han, Jie; Qiu, Song; Li, Qingwen; Zhang, Zhiyong; Peng, Lian-Mao
2016-08-10
Top-gated p-type field-effect transistors (FETs) have been fabricated in batch based on carbon nanotube (CNT) network thin films prepared from CNT solution and present high yield and highly uniform performance with small threshold voltage distribution with standard deviation of 34 mV. According to the property of FETs, various logical and arithmetical gates, shifters, and d-latch circuits were designed and demonstrated with rail-to-rail output. In particular, a 4-bit adder consisting of 140 p-type CNT FETs was demonstrated with higher packing density and lower supply voltage than other published integrated circuits based on CNT films, which indicates that CNT based integrated circuits can reach to medium scale. In addition, a 2-bit multiplier has been realized for the first time. Benefitted from the high uniformity and suitable threshold voltage of CNT FETs, all of the fabricated circuits based on CNT FETs can be driven by a single voltage as small as 2 V.
DEFF Research Database (Denmark)
Johansson, Jens; Nielsen, Mogens Peter
The uniform flow around a circular cylinder at Reynolds number 1e5 is simulated in a three dimensional domain by means of the newly developed Self-induced angular Moment Method, SMoM, turbulence model. The global force coefficients, Strouhal number, pressure distributions and wall shear stress...... distributions are compared to experimental findings reported in literature. The SMoM turbulence model is found to provide maximum, minimum and time-mean pressure coefficient distributions in very good agreement with experimental findings....
International Nuclear Information System (INIS)
Lameiras, F.S.
1991-01-01
Two fundamental principles were assumed to govern the restructuring of microparticles: minimization and uniformization in space of the interface energy. Five fundamental ways, independent of each other and acting simultaneously, were identified, through which a microparticle set can be restructured according to the fundamental principles: a) decrease of the number of microparticles; b) modification of the microparticle size distribution; c) modification of the microparticles from tending to an equiaxial one; d) tendency to the distribution of microparticles uniform in space; e) tendency to the distribution of the interface energy uniform per microparticle. This presents an analytical derivation of the steady-state microparticle size distribution due to the simultaneous action of the fundamental ways b) and e). (author)
Flow distribution in the accelerator-production-of-tritium target
International Nuclear Information System (INIS)
Siebe, D.A.; Spatz, T.L.; Pasamehmetoglu, K.O.; Sherman, M.P.
1999-01-01
Achieving nearly uniform flow distributions in the accelerator production of tritium (APT) target structures is an important design objective. Manifold effects tend to cause a nonuniform distribution in flow systems of this type, although nearly even distribution can be achieved. A program of hydraulic experiments is underway to provide a database for validation of calculational methodologies that may be used for analyzing this problem and to evaluate the approach with the most promise for achieving a nearly even flow distribution. Data from the initial three tests are compared to predictions made using four calculational methods. The data show that optimizing the ratio of the supply-to-return-manifold areas can produce an almost even flow distribution in the APT ladder assemblies. The calculations compare well with the data for ratios of the supply-to-return-manifold areas spanning the optimum value. Thus, the results to date show that a nearly uniform flow distribution can be achieved by carefully sizing the supply and return manifolds and that the calculational methods available are adequate for predicting the distributions through a range of conditions
Energy Technology Data Exchange (ETDEWEB)
Kim, Ho Chul; Lee, Young Jin [Dept. of Radiological Science, Eulji University, Seongnam (Korea, Republic of); Kim, Hee Joung; Kim, Kyuseok; Lee, Min Hee [Yonsei University, Wonju (Korea, Republic of)
2017-06-15
To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a {sup 99m}Tc gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.
International Nuclear Information System (INIS)
Booth, J.T.; Zavgorodni, S.F.; Royal Adelaide Hospital, SA
2001-01-01
Uncertainty in the precise quantity of radiation dose delivered to tumours in external beam radiotherapy is present due to many factors, and can result in either spatially uniform (Gaussian) or spatially non-uniform dose errors. These dose errors are incorporated into the calculation of tumour control probability (TCP) and produce a distribution of possible TCP values over a population. We also study the effect of inter-patient cell sensitivity heterogeneity on the population distribution of patient TCPs. This study aims to investigate the relative importance of these three uncertainties (spatially uniform dose uncertainty, spatially non-uniform dose uncertainty, and inter-patient cell sensitivity heterogeneity) on the delivered dose and TCP distribution following a typical course of fractionated external beam radiotherapy. The dose distributions used for patient treatments are modelled in one dimension. Geometric positioning uncertainties during and before treatment are considered as shifts of a pre-calculated dose distribution. Following the simulation of a population of patients, distributions of dose across the patient population are used to calculate mean treatment dose, standard deviation in mean treatment dose, mean TCP, standard deviation in TCP, and TCP mode. These parameters are calculated with each of the three uncertainties included separately. The calculations show that the dose errors in the tumour volume are dominated by the spatially uniform component of dose uncertainty. This could be related to machine specific parameters, such as linear accelerator calibration. TCP calculation is affected dramatically by inter-patient variation in the cell sensitivity and to a lesser extent by the spatially uniform dose errors. The positioning errors with the 1.5 cm margins used cause dose uncertainty outside the tumour volume and have a small effect on mean treatment dose (in the tumour volume) and tumour control. Copyright (2001) Australasian College of
A quantitative experimental phantom study on MRI image uniformity.
Felemban, Doaa; Verdonschot, Rinus G; Iwamoto, Yuri; Uchiyama, Yuka; Kakimoto, Naoya; Kreiborg, Sven; Murakami, Shumei
2018-05-02
Our goal was to assess MR image uniformity by investigating aspects influencing said uniformity via a method laid out by the National Electrical Manufacturers Association (NEMA). Six metallic materials embedded in a glass phantom were scanned (i.e., Au, Ag, Al, Au-Ag-Pd alloy, Ti and Co-Cr alloy) as well as a reference image. Sequences included Spin Echo (SE) and gradient echo (GRE) scanned in three planes (i.e., Axial, Coronal, and Sagittal). Moreover, three surface coil types (i.e., Head and Neck or HN, Brain, and TMJ coils) and two image correction methods (i.e., Surface Coil Intensity Correction or SCIC, Phased array Uniformity Enhancement or PURE) were employed to evaluate their effectiveness on image uniformity. Image uniformity was assessed using the NEMA peak-deviation non-uniformity method. Results showed that TMJ coils elicited the least uniform image and Brain coils outperformed HN coils when metallic materials were present. Additionally, when metallic materials were present, SE outperformed GRE especially for Co-Cr (particularly in the axial plane). Furthermore, both SCIC and PURE improved image uniformity compared to uncorrected images, and SCIC slightly surpassed PURE when metallic metals were present. Lastly, Co-Cr elicited the least uniform image while other metallic materials generally showed similar patterns (i.e., no significant deviation from images without metallic metals). Overall, a quantitative understanding of the factors influencing MR image uniformity (e.g., coil type, imaging method, metal susceptibility, and post-hoc correction method) is advantageous to optimize image quality, assists clinical interpretation, and may result in improved medical and dental care.
Internal electric-field-lines distribution in CdZnTe detectors measured using X-ray mapping
International Nuclear Information System (INIS)
Bolotnikov, A.E.; Camarda, G.S.; Cui, Y.; Hossain, A.; Yang, G.; Yao, H.W.; James, R.B.
2009-01-01
The ideal operation of CdZnTe devices entails having a uniformly distributed internal electric field. Such uniformity especially is critical for thick long-drift-length detectors, such as large-volume CPG and 3-D multi-pixel devices. Using a high-spatial resolution X-ray mapping technique, we investigated the distribution of the electric field in real devices. Our measurements demonstrate that in thin detectors, 1 cm, with a large aspect ratio (thickness-to-width ratio), we observed two effects: the electric field lines bending away from or towards the side surfaces, which we called, respectively, the focusing field-line distribution and the defocusing field-line distribution. In addition to these large-scale variations, the field-line distributions were locally perturbed by the presence of extended defects and residual strains existing inside the crystals. We present our data clearly demonstrating the non-uniformity of the internal electric field
MAPI: a software framework for distributed biomedical applications
Directory of Open Access Journals (Sweden)
Karlsson Johan
2013-01-01
Full Text Available Abstract Background The amount of web-based resources (databases, tools etc. in biomedicine has increased, but the integrated usage of those resources is complex due to differences in access protocols and data formats. However, distributed data processing is becoming inevitable in several domains, in particular in biomedicine, where researchers face rapidly increasing data sizes. This big data is difficult to process locally because of the large processing, memory and storage capacity required. Results This manuscript describes a framework, called MAPI, which provides a uniform representation of resources available over the Internet, in particular for Web Services. The framework enhances their interoperability and collaborative use by enabling a uniform and remote access. The framework functionality is organized in modules that can be combined and configured in different ways to fulfil concrete development requirements. Conclusions The framework has been tested in the biomedical application domain where it has been a base for developing several clients that are able to integrate different web resources. The MAPI binaries and documentation are freely available at http://www.bitlab-es.com/mapi under the Creative Commons Attribution-No Derivative Works 2.5 Spain License. The MAPI source code is available by request (GPL v3 license.
School Dress Codes and Uniform Policies.
Anderson, Wendell
2002-01-01
Opinions abound on what students should wear to class. Some see student dress as a safety issue; others see it as a student-rights issue. The issue of dress codes and uniform policies has been tackled in the classroom, the boardroom, and the courtroom. This Policy Report examines the whole fabric of the debate on dress codes and uniform policies…
Uniforms, status and professional boundaries in hospital.
Timmons, Stephen; East, Linda
2011-11-01
Despite their comparative neglect analytically, uniforms play a key role in the delineation of occupational boundaries and the formation of professional identity in healthcare. This paper analyses a change to the system of uniforms in one UK hospital, where management have required all professions (with the exception of doctors) to wear the same 'corporate' uniform. Focus groups were conducted with the professionals and patients. We analyse this initiative as a kind of McDonaldisation, seeking to create a new 'corporate' worker whose allegiance is principally to the organisation, rather than a profession. Our findings show how important uniforms are to their wearers, both in terms of the defence of professional boundaries and status, as well as the construction of professional identity. © 2011 The Authors. Sociology of Health & Illness © 2011 Foundation for the Sociology of Health & Illness/Blackwell Publishing Ltd.
Non-uniform sampling of NMR relaxation data
DEFF Research Database (Denmark)
Schwarz-Linnet, Troels; Teilum, Kaare
2016-01-01
The use of non-uniform sampling of NMR spectra may give significant reductions in the data acquisition time. For quantitative experiments such as the measurement of spin relaxation rates, non-uniform sampling is however not widely used as inaccuracies in peak intensities may lead to errors...... in the extracted dynamic parameters. By systematic reducing the coverage of the Nyquist grid of (15)N Carr-Purcell-Meiboom-Gill (CPMG) relaxation dispersion datasets for four different proteins and performing a full data analysis of the resulting non-uniform sampled datasets, we have compared the performance...... of the multi-dimensional decomposition and iterative re-weighted least-squares algorithms in reconstructing spectra with accurate peak intensities. As long as a single fully sampled spectrum is included in a series of otherwise non-uniform sampled two-dimensional spectra, multi-dimensional decomposition...
Dijk, Peter H.; Heikamp, A; Bambang Oetomo, Sidarto
1997-01-01
Objective: Surfactant nebulisation is a promising alternative to surfactant instillation in newborns with the respiratory distress syndrome. Although less surfactant is deposited in the lung, it improves gas exchange, probably due to a superior distribution. We hypothesize that a more uniform
Study on effects of mixing vane grids on coolant temperature distribution by subchannel analysis
Energy Technology Data Exchange (ETDEWEB)
Mao, H.; Yang, B.W.; Han, B. [Xi' an Jiaotong Univ., Shaanxi (China). Science and Technology Center for Advanced Nuclear Fuel Research
2016-07-15
Mixing vane grids (MVG) have great influence on coolant temperature field in the rod bundle. The MVG could enhance convective heat transfer between the fuel rod wall and the coolant, and promote inter-subchannel mixing at the same time. For the influence of the MVG on convective heat transfer enhancement, many experiments have been done and several correlations have been developed based on the experimental data. However, inter-subchannel mixing promotion caused by the MVG is not well estimated in subchannel analysis because the information of mixing vanes is totally missing in most subchannel codes. This paper analyzes the influence of mixing vanes on coolant temperature distribution using the improved MVG model in subchannel analysis. The coolant temperature distributions with the MVG are analyzed, and the results show that mixing vanes lead to a more uniform temperature distribution. The performances of split vane grids under different power conditions are evaluated. The results are compared with those of spacer grids without mixing vanes and some conclusions are obtained.
Study on effects of mixing vane grids on coolant temperature distribution by subchannel analysis
International Nuclear Information System (INIS)
Mao, H.; Yang, B.W.; Han, B.
2016-01-01
Mixing vane grids (MVG) have great influence on coolant temperature field in the rod bundle. The MVG could enhance convective heat transfer between the fuel rod wall and the coolant, and promote inter-subchannel mixing at the same time. For the influence of the MVG on convective heat transfer enhancement, many experiments have been done and several correlations have been developed based on the experimental data. However, inter-subchannel mixing promotion caused by the MVG is not well estimated in subchannel analysis because the information of mixing vanes is totally missing in most subchannel codes. This paper analyzes the influence of mixing vanes on coolant temperature distribution using the improved MVG model in subchannel analysis. The coolant temperature distributions with the MVG are analyzed, and the results show that mixing vanes lead to a more uniform temperature distribution. The performances of split vane grids under different power conditions are evaluated. The results are compared with those of spacer grids without mixing vanes and some conclusions are obtained.
Uniform excitations in magnetic nanoparticles
Directory of Open Access Journals (Sweden)
Steen Mørup
2010-11-01
Full Text Available We present a short review of the magnetic excitations in nanoparticles below the superparamagnetic blocking temperature. In this temperature regime, the magnetic dynamics in nanoparticles is dominated by uniform excitations, and this leads to a linear temperature dependence of the magnetization and the magnetic hyperfine field, in contrast to the Bloch T3/2 law in bulk materials. The temperature dependence of the average magnetization is conveniently studied by Mössbauer spectroscopy. The energy of the uniform excitations of magnetic nanoparticles can be studied by inelastic neutron scattering.
Uniform excitations in magnetic nanoparticles
DEFF Research Database (Denmark)
Mørup, Steen; Frandsen, Cathrine; Hansen, Mikkel Fougt
2010-01-01
We present a short review of the magnetic excitations in nanoparticles below the superparamagnetic blocking temperature. In this temperature regime, the magnetic dynamics in nanoparticles is dominated by uniform excitations, and this leads to a linear temperature dependence of the magnetization...... and the magnetic hyperfine field, in contrast to the Bloch T3/2 law in bulk materials. The temperature dependence of the average magnetization is conveniently studied by Mössbauer spectroscopy. The energy of the uniform excitations of magnetic nanoparticles can be studied by inelastic neutron scattering....
IOOS Data Portals and Uniform On-line Browse Capabilities
Howard, M.; Currier, R. D.; Kobara, S.; Gayanilo, F.
2015-12-01
The Gulf of Mexico Coastal Ocean Observing System Regional Association (GCOOS-RA) is one of eleven Regional Associations organized under the NOAA-led U.S. Integrated Ocean Observing System (IOOS) Program Office. Each of the RAs operate standards-based regional data portals designed to aggregate near real-time and historical observed data and modeled outputs from distributed providers and to offer these and derived products in standardized ways to a diverse set of users. The RA's portals are based on the IOOS Data and Communications Plan which describes the functional elements needed for an interoperable system. One of these elements is called "Uniform On-line Browse" which is an informational service designed primarily to visualize the inventory of a portal. An on-line browse service supports the end user's need to discover what parameters are available, to learn the spatial and temporal extend of the holdings, and to examine the character of the data (e.g, variability, gappiness, etc). These pieces of information help the end user decide if the data are fit for his/her purpose and to construct valid data requests. Note that on-line browse is a distinctly different activity than data analysis because it seeks to yield knowledge about the inventory and not about what the data mean. "Uniform" on-line browse is a service that takes advantage of the standardization of the data portal's data access points. Most portals represent station locations on a map. This is a view of the data inventory but these plots are rarely generated by pulling data through the standards-based services offered to the end users but through methods only available to the portal programmers. This work will present results of Uniform On-line browse tools developed within GCOOS-RA and their applicability to other RA portals.
Energy Technology Data Exchange (ETDEWEB)
Vitaly Osmachkin [Russian Research Center ' Kurchatov Institute' 1, Kurchatov sq, Moscow 123182 (Russian Federation)
2005-07-01
Full text of publication follows: The influence of power transient, changes of flow rate, inlet temperatures or pressure in cores of nuclear reactors on heat transfer and burnout conditions in channels depend on rate of such violations. Non-uniform distribution of the heat flux is also important factor for heat transfer and development of crisis phenomenon. Such effects may be significant for NPPs safety. But they have not yet generally accepted interpretation. Steady state approach is often recommended for use in calculations. In the paper a review of experimental observed so-called non-equilibrium effects is presented. The effects of space and time factors are displaying due delay in reformation turbulence intensity, velocity, temperatures or void fraction profiles, water film flow on the surface of heated channels. For estimation of such effect different methods are used. Modern computer codes based on two or three fluids approaches are considered as most effective. But simple and clear correlations may light up the mechanics of effects on heat transfer and improve general understanding of scale and significance of the transient events. In the paper the simplified methods for assessment the influence of lags in the development of distributions of parameters of flow, the relaxation of temporal or space violations are considered. They are compared with more sophisticated approaches. Velocities of disturbance fronts moving along the channels are discussed also. (author)
Modelling of temperature distribution and pulsations in fast reactor units
International Nuclear Information System (INIS)
Ushakov, P.A.; Sorokin, A.P.
1994-01-01
Reasons for the occurrence of thermal stresses in reactor units have been analyzed. The main reasons for this analysis are: temperature non-uniformity at the output of reactor core and breeder and the ensuing temperature pulsation; temperature pulsations due to mixing of sodium jets of a different temperature; temperature nonuniformity and pulsations resulting from the part of loops (circuits) un-plug; temperature nonuniformity and fluctuations in transient and accidental shut down of reactor or transfer to cooling by natural circulation. The results of investigating the thermal hydraulic characteristics are obtained by modelling the processes mentioned above. Analysis carried out allows the main lines of investigation to be defined and conclusions can be drawn regarding the problem of temperature distribution and fluctuation in fast reactor units
International Nuclear Information System (INIS)
Wen Xiaoqiong; Li Qiang; Zhou Guangming; Li Wenjian; Wei Zengquan
2001-01-01
In order to estimate the influence of the un-uniform dose distribution on the clinical treatment result, the Influence of dose distribution homogeneity on the tumor control probability was investigated. Basing on the formula deduced previously for survival fraction of cells irradiated by the un-uniform heavy-ion irradiation field and the theory of tumor control probability, the tumor control probability was calculated for a tumor mode exposed to different dose distribution homogeneity. The results show that the tumor control probability responding to the same total dose will decrease if the dose distribution homogeneity gets worse. In clinical treatment, the dose distribution homogeneity should be better than 95%
Investigation of uniformity field generated from freeform lens with UV LED exposure system
Ciou, F. Y.; Chen, Y. C.; Pan, C. T.; Lin, P. H.; Lin, P. H.; Hsu, F. T.
2015-03-01
In the exposure process, the intensity and uniformity of light in the exposure area directly influenced the precision of products. UV-LED (Ultraviolet Light-Emitting Diode) exposure system was established to reduce the radiation leakage and increase the energy efficiency for energy saving. It is a trend that conventional mercury lamp could be replaced with UV-LED exposure system. This study was based on the law of conservation of energy and law of refraction of optical field distributing on the target plane. With these, a freeform lens with uniform light field of main exposure area could be designed. The light outside the exposure area could be concentrated into the area to improve the intensity of light. The refraction index and UV transmittance of Polydimethylsiloxane (PDMS) is 1.43 at 385 nm wavelength and 85-90%, respectively. The PDMS was used to fabricate the optics lens for UV-LEDs. The average illumination and the uniformity could be obtained by increasing the number of UV-LEDs and the spacing of different arrangement modes. After exposure process with PDMS lens, about 5% inaccuracy was obtained. Comparing to 10% inaccuracy of general exposure system, it shows that it is available to replace conventional exposure lamp with using UV-LEDs.
Design and validation of a uniform flow microreactor
Energy Technology Data Exchange (ETDEWEB)
Yi, Seung Jae; Kim, Kyung Chun; Chang, Seung Cheol [Pusan National University, Busan (Korea, Republic of); Park, Ji Min [Global HQ, Hankook Tire Co., Daejeon (Korea, Republic of)
2014-01-15
We present a design method to characterize uniform flows in a microreactor for high performance surface plasmon resonance (SPR) a general-purpose biosensor chips. The shape of the microreactor is designed based on an approximate pressure drop model. The number of micro-pillars and the slopes of the inlet and outlet linear chambers are two dominant parameters used to minimize the velocity difference in the microreactor. The flow uniformity was examined quantitatively by numerical and experimental visualization methods. A computational fluid dynamics (CFD) analysis demonstrates that the designed microreactor has a fairly uniform velocity profile in the reaction zone for a wide range of flow rates. The velocity field in the fabricated microreactor was measured using the micro-particle image velocimetry (μ-PIV) method, and the flow uniformity was confirmed experimentally. The performance of the uniform flow microreactor was verified using the fluorescence antibody technique.
Temperature distribution of a simplified rotor due to a uniform heat source
Welzenbach, Sarah; Fischer, Tim; Meier, Felix; Werner, Ewald; kyzy, Sonun Ulan; Munz, Oliver
2018-03-01
In gas turbines, high combustion efficiency as well as operational safety are required. Thus, labyrinth seal systems with honeycomb liners are commonly used. In the case of rubbing events in the seal system, the components can be damaged due to cyclic thermal and mechanical loads. Temperature differences occurring at labyrinth seal fins during rubbing events can be determined by considering a single heat source acting periodically on the surface of a rotating cylinder. Existing literature analysing the temperature distribution on rotating cylindrical bodies due to a stationary heat source is reviewed. The temperature distribution on the circumference of a simplified labyrinth seal fin is calculated using an available and easy to implement analytical approach. A finite element model of the simplified labyrinth seal fin is created and the numerical results are compared to the analytical results. The temperature distributions calculated by the analytical and the numerical approaches coincide for low sliding velocities, while there are discrepancies of the calculated maximum temperatures for higher sliding velocities. The use of the analytical approach allows the conservative estimation of the maximum temperatures arising in labyrinth seal fins during rubbing events. At the same time, high calculation costs can be avoided.
International Nuclear Information System (INIS)
Son, Soon Yong; Lee, Hee Jeong; Lee, Won Hong; Cho, Cheong Chan; Ryu, Meung Sun; Jung, Hong Ryang
2001-01-01
Over-density of pancreatic duct tail part on the endoscopic retrograde pancreatogram results from patient's position and inserted air during the study. The aim of this paper is to decide the filter angle to obtain an uniform density. Endoscopic retrograde pancratography was performed to 234 patients, and angled wedge filter was used differently. They are 10 deg (47), 20 deg (45), 30 deg (50). We also did not use wedge filter to 42 patients. We decided reliance degree in 95%. The statistical difference was p<0.05. The patients' sex rate was 1.8:1 between 18 and 87 years old(average age 58 years). Their body girth was 18.71 cm on the average. Of total 234 patients, difference of right and left average density was 0.01 by 30 deg wedge filter, -0.08 40 deg wedge filter and 0.27 non-wedge filter. These average values of difference density were very significant statistically, and standard deviation also was close to regular distribution. In conclusion, there is a usefulness of angled wedge filter for increasing diagnostic value of pancreatic duct tail part on the endoscopic retrograde pancreatogram
Thermal interaction effect on nucleation site distribution in subcooled boiling
International Nuclear Information System (INIS)
Zou, Ling; Jones, Barclay
2012-01-01
An experimental work on subcooled boiling of refrigerant, R134a, to examine nucleation site distributions on both copper and stainless steel heating surfaces was performed. In order to obtain high fidelity active nucleation site density and distribution data, a high-speed digital camera was utilized to record bubble emission images from a view normal to heating surfaces. Statistical analyses on nucleation site data were done and their statistical distributions were obtained. Those experimentally observed nucleation site distributions were compared to the random spatial Poisson distribution. The comparisons showed that, rather than purely random, active nucleation site distributions on boiling surfaces are relatively more uniform. Experimental results also showed that on the copper heating surface, nucleation site distributions are slightly more uniform than on the stainless steel surface. This was concluded as the results of thermal interactions between nucleation sites with different solid thermal conductivities. A two dimensional thermal interaction model was then developed to quantitatively examine the thermal interactions between nucleation sites. The results give a reasonable explanation to the experimental observation on nucleation site distributions.
International Nuclear Information System (INIS)
Xia, Min; Yan, Qingzhi; Xu, Lei; Guo, Hongyan; Zhu, Lingxu; Ge, Changchun
2013-01-01
Graphical abstract: La 2 O 3 doped La 2 O 3 /W nanoparticles with high-purity and uniform diameters have been fabricated by a co-precipitation process. The as-prepared nanoparticles demonstrate the potential of this method for fabricating uniformly structured bulk tungsten materials. -- Abstract: We report the preparation of 1 wt% La 2 O 3 doped La 2 O 3 /W nanoparticles by a co-precipitation process, using ammonium metatungstate (AMT) and lanthanum nitrate as raw materials. The as-synthesized nanoparticles were characterized by X-ray diffraction, Filed-emission scanning electron microscopy, Transmission electron microscopy (TEM), energy dispersive spectroscopy. Our results reveal that the as-synthesized particles possess uniform diameters of about 70 nm, and are of high purity. The TEM and the corresponding fast Fourier transform images demonstrated that La 2 O 3 precipitates were homogeneously doped into the nano-sized tungsten particles. When the as-synthesized nanoparticles were sintered by spark plasma sintering, the electron backscatter diffraction images of the bulk material reveal that La 2 O 3 nanoparticles were homogenously distributed in both the tungsten grains and the grain boundaries, and the sample exhibit a narrow micro-hardness distribution
On Uniform Exponential Trichotomy in Banach Spaces
Directory of Open Access Journals (Sweden)
Kovacs Monteola Ilona
2014-06-01
Full Text Available In this paper we consider three concepts of uniform exponential trichotomy on the half-line in the general framework of evolution operators in Banach spaces. We obtain a systematic classification of uniform exponential trichotomy concepts and the connections between them.
ELECTRONIC CIRCUIT BOARDS NON-UNIFORM COOLING SYSTEM MODEL
Directory of Open Access Journals (Sweden)
D. V. Yevdulov
2016-01-01
Full Text Available Abstract. The paper considers a mathematical model of non-uniform cooling of electronic circuit boards. The block diagram of the system implementing this approach, the method of calculation of the electronic board temperature field, as well as the principle of its thermal performance optimizing are presented. In the considered scheme the main heat elimination from electronic board is produced by the radiator system, and additional cooling of the most temperature-sensitive components is produced by thermoelectric batteries. Are given the two-dimensional temperature fields of the electronic board during its uniform and non-uniform cooling, is carried out their comparison. As follows from the calculations results, when using a uniform overall cooling of electronic unit there is a waste of energy for the cooling 0f electronic board parts which temperature is within acceptable temperature range without the cooling system. This approach leads to the increase in the cooling capacity of used thermoelectric batteries in comparison with the desired values. This largely reduces the efficiency of heat elimination system. The use for electronic boards cooling of non-uniform local heat elimination removes this disadvantage. The obtained dependences show that in this case, the energy required to create a given temperature is smaller than when using a common uniform cooling. In this approach the temperature field of the electronic board is more uniform and the cooling is more efficient.
Effects of shape and size of agar gels on heating uniformity during pulsed microwave treatment.
Soto-Reyes, Nohemí; Temis-Pérez, Ana L; López-Malo, Aurelio; Rojas-Laguna, Roberto; Sosa-Morales, María Elena
2015-05-01
Model gel systems with different shape (sphere, cylinder, and slab) and size (180 and 290 g) were prepared with agar (5%) and sucrose (5%). Dielectric constant (ε'), loss factor (ε"), thermophysical properties, and temperature distribution of the model system were measured. Each agar model system was immersed and suspended in water, and then, heated in a microwave oven with intermittent heating until the core temperature reached 50 °C. The ε' and ε" of agar gels decreased when frequency increased. The density and thermal conductivity values of the agar gels were 1033 kg/m(3) and 0.55 W/m °C, respectively. The temperature distribution of sphere, cylinder, and slab was different when similar power doses were applied. The slab reached 50 °C in less time (10 min) and showed a more uniform heating than spheres and cylinders in both sizes. Agar model systems of 180 g heated faster than those of 290 g. The coldest point was the center of the model systems in all studied cases. Shape and size are critical food factors that affect the heating uniformity during microwave heating processes. © 2015 Institute of Food Technologists®
7 CFR 51.2085 - Fairly uniform color.
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Fairly uniform color. 51.2085 Section 51.2085 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... color. Fairly uniform color means that the shells do not show excessive variation in color, whether...
International Nuclear Information System (INIS)
Miyahara, Hiroshi; Yoshida, Makoto; Watanabe, Tamaki
1977-01-01
The α-ray thickness gauge is used to measure non-destructively the thicknesses of thin films, and up to the present day, a thin film with uniform thickness is only taken up as the object of α-ray thickness gauge. When the thickness is determined from the displacement between the absorption curves in the presence and absence of thin film, the absorption curve must be displaced in parallel. When many uniform particles were dispersed as sample, the shape of the absorption curve was calculated as the sum of many absorption curves corresponding to the thin films with different thicknesses. By the comparison of the calculated and measured absorption curves, the number of particles, or the mean superficial density can be determined. This means the extension of thickness measurement from uniform to non-uniform films. Furthermore, these particle models being applied to non-uniform thin film, the possibility of measuring the mean thickness and non-uniformity was discussed. As the result, if the maximum difference of the thickness was more than 0.2 mg/cm 2 , the nonuniformity was considered to distinguish by the usual equipment. In this paper, an α-ray thickness gauge using the absorption curve method was treated, but one can apply this easily to an α-ray thickness gauge using α-ray energy spectra before and after the penetration of thin film. (auth.)
ESPRIT And Uniform Linear Arrays
Roy, R. H.; Goldburg, M.; Ottersten, B. E.; Swindlehurst, A. L.; Viberg, M.; Kailath, T.
1989-11-01
Abstract ¬â€?ESPRIT is a recently developed and patented technique for high-resolution estimation of signal parameters. It exploits an invariance structure designed into the sensor array to achieve a reduction in computational requirements of many orders of magnitude over previous techniques such as MUSIC, Burg's MEM, and Capon's ML, and in addition achieves performance improvement as measured by parameter estimate error variance. It is also manifestly more robust with respect to sensor errors (e.g. gain, phase, and location errors) than other methods as well. Whereas ESPRIT only requires that the sensor array possess a single invariance best visualized by considering two identical but other-wise arbitrary arrays of sensors displaced (but not rotated) with respect to each other, many arrays currently in use in various applications are uniform linear arrays of identical sensor elements. Phased array radars are commonplace in high-resolution direction finding systems, and uniform tapped delay lines (i.e., constant rate A/D converters) are the rule rather than the exception in digital signal processing systems. Such arrays possess many invariances, and are amenable to other types of analysis, which is one of the main reasons such structures are so prevalent. Recent developments in high-resolution algorithms of the signal/noise subspace genre including total least squares (TLS) ESPRIT applied to uniform linear arrays are summarized. ESPRIT is also shown to be a generalization of the root-MUSIC algorithm (applicable only to the case of uniform linear arrays of omni-directional sensors and unimodular cisoids). Comparisons with various estimator bounds, including CramerRao bounds, are presented.
Mehta, Shraddha; Bastero-Caballero, Rowena F; Sun, Yijun; Zhu, Ray; Murphy, Diane K; Hardas, Bhushan; Koch, Gary
2018-04-29
Many published scale validation studies determine inter-rater reliability using the intra-class correlation coefficient (ICC). However, the use of this statistic must consider its advantages, limitations, and applicability. This paper evaluates how interaction of subject distribution, sample size, and levels of rater disagreement affects ICC and provides an approach for obtaining relevant ICC estimates under suboptimal conditions. Simulation results suggest that for a fixed number of subjects, ICC from the convex distribution is smaller than ICC for the uniform distribution, which in turn is smaller than ICC for the concave distribution. The variance component estimates also show that the dissimilarity of ICC among distributions is attributed to the study design (ie, distribution of subjects) component of subject variability and not the scale quality component of rater error variability. The dependency of ICC on the distribution of subjects makes it difficult to compare results across reliability studies. Hence, it is proposed that reliability studies should be designed using a uniform distribution of subjects because of the standardization it provides for representing objective disagreement. In the absence of uniform distribution, a sampling method is proposed to reduce the non-uniformity. In addition, as expected, high levels of disagreement result in low ICC, and when the type of distribution is fixed, any increase in the number of subjects beyond a moderately large specification such as n = 80 does not have a major impact on ICC. Copyright © 2018 John Wiley & Sons, Ltd.
Energy Technology Data Exchange (ETDEWEB)
Zhang, Hualin, E-mail: hualin.zhang@northwestern.edu; Donnelly, Eric D.; Strauss, Jonathan B. [Department of Radiation Oncology, Robert H. Lurie Comprehensive Cancer Center, Northwestern University Feinberg School of Medicine, Northwestern Memorial Hospital, Chicago, Illinois 60611 (United States); Qi, Yujin [Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)
2016-01-15
.4){sup 4} for the radiosensitive normal tissue depending on the cylinder size, treatment lengths, prescription depth, and dose as well. However, for a uniform cancer cell distribution, the EUDs were between 6.3 Gy × 4 and 7.1 Gy × 4, and the TRs were found to be between (1.4){sup 4} and (1.7){sup 4}. For the uniformly interspersed cancer and radio-resistant normal cells, the TRs were less than 1. The two VCBT prescription regimens were found to be equivalent in terms of EUDs and TRs. Conclusions: HDR VCBT strongly favors cylindrical target volume with the cancer cell distribution following its dosimetric trend. Assuming a half-Gaussian distribution of cancer cells, the HDR VCBT provides a considerable radiobiological advantage over the external beam radiotherapy (EBRT) in terms of sparing more normal tissues while maintaining the same level of cancer cell killing. But for the uniform cancer cell distribution and radio-resistant normal tissue, the radiobiology outcome of the HDR VCBT does not show an advantage over the EBRT. This study strongly suggests that radiation therapy design should consider the cancer cell distribution inside the target volume in addition to the shape of target.
International Nuclear Information System (INIS)
Tubiana, M.
1993-01-01
In conclusion, a general consensus of a number of points which the author endeavours to summarize in this article: -doctors are an excellent channel for passing on information to the public -doctors feel that they do not know enough about the subject and a training on radiobiology and radiation protection is a necessity for them -communication between doctors and the general public is poor in this field -research should be encouraged in numerous areas such as: carcinogenic effect of low doses of radiation, pedagogy and risk perception
Quasiparticles in non-uniformly magnetized plasma
International Nuclear Information System (INIS)
Sosenko, P.P.
1994-01-01
A quasiparticle concept is generalized for the case of non-uniformly magnetized plasma. Exact and reduced continuity equations for the microscopic density in the quasiparticle phase space are derived, and the nature of quasiparticles is analyzed. The theory is developed for the general case of relativistic particles in electromagnetic fields, besides non-uniform but stationary magnetic fields. Effects of non-stationary magnetic fields are briefly investigated also. 26 refs
On the Invariant Uniform Roe Algebra as Crossed Product
Kankeyanathan Kannan
2013-01-01
The uniform Roe C*-algebra (also called uniform translation)C^*- algebra provides a link between coarse geometry and C^*- algebra theory. The uniform Roe algebra has a great importance in geometry, topology and analysis. We consider some of the elementary concepts associated with coarse spaces.
International Nuclear Information System (INIS)
Stevens, G.F.; Elliott, D.F.; Wood, R.W.
1965-05-01
Some correlations of forced convection burn-out data are based on the approximate linearity of the relationship between burn-out heat flux and the channel-averaged quality at the burn-out point. These correlations perform satisfactorily on data obtained from uniformly heated configurations. Therefore the further inference is sometimes made that the burn-out heat flux is uniquely related to the quality, and that the burn-out in non-uniformly heated configurations can be calculated from measurements made with uniform heating. This report presents burn-out data for Freon 12 flowing vertically upwards through both uniformly and non-uniformly heated round tubes. This data shows that the quality at burn-out does depend on the heat flux profile, and that the inference mentioned above is not justified. (author)
School Uniform Policies: Students' Views of Effectiveness.
McCarthy, Teresa M.; Moreno, Josephine
2001-01-01
Focus-group interviews of New York City middle-school students about their perceptions of the effectiveness of the school-uniform policy. Finds that students' perceptions of the effects of school-uniform policy on school culture varied considerably with those intended by the principal. (Contains 40 references.) (PKP)
44 CFR 12.18 - Uniform pay guidelines.
2010-10-01
... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Uniform pay guidelines. 12.18 Section 12.18 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY GENERAL ADVISORY COMMITTEES § 12.18 Uniform pay guidelines. (a) Members. Subject to the...
A scanning point source for quality control of FOV uniformity in GC-PET imaging
International Nuclear Information System (INIS)
Bergmann, H.; Minear, G.; Dobrozemsky, G.; Nowotny, R.; Koenig, B.
2002-01-01
Aim: PET imaging with coincidence cameras (GC-PET) requires additional quality control procedures to check the function of coincidence circuitry and detector zoning. In particular, the uniformity response over the field of view needs special attention since it is known that coincidence counting mode may suffer from non-uniformity effects not present in single photon mode. Materials and methods: An inexpensive linear scanner with a stepper motor and a digital interface to a PC with software allowing versatile scanning modes was developed. The scanner is used with a source holder containing a Sodium-22 point source. While moving the source along the axis of rotation of the GC-PET system, a tomographic acquisition takes place. The scan covers the full axial field of view of the 2-D or 3-D scatter frame. Depending on the acquisition software, point source scanning takes place continuously while only one projection is acquired or is done in step-and-shoot mode with the number of positions equal to the number of gantry steps. Special software was developed to analyse the resulting list mode acquisition files and to produce an image of the recorded coincidence events of each head. Results: Uniformity images of coincidence events were obtained after further correction for systematic sensitivity variations caused by acquisition geometry. The resulting images are analysed visually and by calculating NEMA uniformity indices as for a planar flood field. The method has been applied successfully to two different brands of GC-PET capable gamma cameras. Conclusion: Uniformity of GC-PET can be tested quickly and accurately with a routine QC procedure, using a Sodium-22 scanning point source and an inexpensive mechanical scanning device. The method can be used for both 2-D and 3-D acquisition modes and fills an important gap in the quality control system for GC-PET
Numerical Investigations on a Distributed Fiber-Optic Lighting System with an End Reflector
International Nuclear Information System (INIS)
Li Shuhua; Gong Huaping; Tu Yumeng; Meng Ying
2011-01-01
A novel distributed fiber-optic decorative lighting system with the reflection coating on the extremity of fiber-optic is designed, which used the multi-mold optical fiber made up of large core diameter(Diameter of core and cladding is 105μm and 125μm, respectly). After introducing the distributional optical fiber decorative lighting system briefly, the ralationship between corrosion depth of the optical fiber core and the leakage of fiber-optic has been analyzed with the Rsoft, and then the relationship of the lighting power and the uniformity of lighting power with the leakage rate of optical fiber lamp, the reflective of reflection coating has been discussed.The simulation analysis shows that, when the core diameter is corroded to 80∼85 μm, the leakage rate of optical fiber may achieve 5.0%, which suits the optical fiber decorative lighting. Considering all kinds of factors, when optical fiber lamp's quantity is 20, the coating index of reflection is 95%, optical fiber lamp's leakage of light rate is 5.0%, and the optical fiber lamp's distance is 1 meter, the quite high illuminating power may be achieved, as well as the good lighting uniformity.Finally the experimental study of decorative lighting system is given. And the experimental result is in keeping well with the theory simulation conclusion.
DEFF Research Database (Denmark)
Kouchaki, Alireza; Iman-Eini, H.; Asaei, B.
2012-01-01
This paper presents a new algorithm based on characteristic equation of solar cells to determine the Maximum Power Point (MPP) of PV modules under partially shaded conditions (PSC). To achieve this goal, an analytic condition is introduced to determine uniform or non-uniform atmospheric condition...
Directory of Open Access Journals (Sweden)
Luwei Zhou
2014-01-01
Full Text Available This study demonstrated that near infrared chemical imaging (NIR-CI was a rapid and nondestructive technique for discrimination of chlorpheniramine maleate (CPM and assessment of its surface content uniformity (SCU in a pharmaceutical formulation. The characteristic wavenumber method was used for discriminating CPM distribution on the tablet surface. To assess the surface content uniformity of CPM, binary image and statistical measurement were proposed. Furthermore, high-performance liquid chromatography (HPLC was used as reference method for accurately determining volume content of CPM in the sample. Moreover, HPLC was performed to assess volume content uniformity (VCU of CPM in whole region and part region of the tablets. The NIR-CI result showed that the spatial distribution of CPM was heterogeneous on the tablet surface. Through the comparison of content uniformity of CPM determined by NIR-CI and HPLC, respectively, it demonstrated that a high degree of VCU did not imply a high degree of SCU of the samples. These results indicate that HPLC method is not suitable for testing SCU, and this has been verified by NIR-CI. This study proves the feasibility of NIR-CI for rapid discrimination of CPM and assessment of its SCU, which is helpful for the quality control of commercial CPM tablets.
Energy Technology Data Exchange (ETDEWEB)
Zeng Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A.; Trofimov, Alexei [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)
2013-05-15
control probability (TCP) and normal tissue complication probability (NTCP). To assess potential local RBE variations, LET distributions were calculated with Monte Carlo, and compared for different plans. The results were assessed in terms of their sensitivity to uncertainties in model parameters and delivery. Results: IFD courses included equal number of fractions boosting either hemisphere, thus, the combined physical dose was close to uniform throughout the prostate. However, for the entire course, the prostate EUD in IFD was higher than in conventional FTP by up to 14%, corresponding to the estimated increase in TCP to 96% from 88%. The extent of gain depended on the mixing factor, i.e., relative weights used to combine FTP and STP spot weights. Increased weighting of STP typically yielded a higher target EUD, but also led to increased sensitivity of dose to variations in the proton's range. Rectal and bladder EUD were same or lower (per normalization), and the NTCP for both remained below 1%. The LET distributions in IFD also depended strongly on the mixing weights: plans using higher weight of STP spots yielded higher LET, indicating a potentially higher local RBE. Conclusions: In proton therapy delivered by pencil beam scanning, improved therapeutic outcome can potentially be expected with delivery of IFD distributions, while administering the prescribed quasi-uniform dose to the target over the entire course. The biological effectiveness of IFD may be further enhanced by optimizing the LET distributions. IFD distributions are characterized by a dose gradient located in proximity of the prostate's midplane, thus, the fidelity of delivery would depend crucially on the precision with which the proton range could be controlled.
International Nuclear Information System (INIS)
Zeng Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A.; Trofimov, Alexei
2013-01-01
control probability (TCP) and normal tissue complication probability (NTCP). To assess potential local RBE variations, LET distributions were calculated with Monte Carlo, and compared for different plans. The results were assessed in terms of their sensitivity to uncertainties in model parameters and delivery. Results: IFD courses included equal number of fractions boosting either hemisphere, thus, the combined physical dose was close to uniform throughout the prostate. However, for the entire course, the prostate EUD in IFD was higher than in conventional FTP by up to 14%, corresponding to the estimated increase in TCP to 96% from 88%. The extent of gain depended on the mixing factor, i.e., relative weights used to combine FTP and STP spot weights. Increased weighting of STP typically yielded a higher target EUD, but also led to increased sensitivity of dose to variations in the proton's range. Rectal and bladder EUD were same or lower (per normalization), and the NTCP for both remained below 1%. The LET distributions in IFD also depended strongly on the mixing weights: plans using higher weight of STP spots yielded higher LET, indicating a potentially higher local RBE. Conclusions: In proton therapy delivered by pencil beam scanning, improved therapeutic outcome can potentially be expected with delivery of IFD distributions, while administering the prescribed quasi-uniform dose to the target over the entire course. The biological effectiveness of IFD may be further enhanced by optimizing the LET distributions. IFD distributions are characterized by a dose gradient located in proximity of the prostate's midplane, thus, the fidelity of delivery would depend crucially on the precision with which the proton range could be controlled.
Production of high energy, uniform focal profiles with the Nike laser
Lehecka, T.; Lehmberg, R. H.; Deniz, A. V.; Gerber, K. A.; Obenschain, S. P.; Pawley, C. J.; Pronko, M. S.; Sullivan, C. A.
1995-02-01
Nike, a KrF laser facility at the Naval Research Laboratory, is designed to produce high intensity, ultra-uniform focal profiles for experiments relating to direct drive inertial confinement fusion. We present measurements of focal profiles through the next-to-last amplifier, a 20 × 20 cm 2 aperture electron beam pumped amplifier capable of producing more than 120 J of output in a 120 ns pulse. Using echelon free induced spatial incoherence beam smoothing this system has produced focal profiles with less than 2% tilt and curvature and less than 2% rms variation from a flat top distribution.
Fouad Fanous; Jeremy May; Terry Wipf; Michael Ritter
2010-01-01
Over the past few years the United States Department of Agriculture (USDA), Forest Products Laboratory (FPL), and the Federal Highway Administration (FHWA) have supported several research programs. This paper is a result of a study sponsored by FPL, with the objective of determining how truckloads are distributed to the deck panels of a longitudinal glued-laminated...
Modelling refrigerant distribution in microchannel evaporators
DEFF Research Database (Denmark)
Brix, Wiebke; Kærn, Martin Ryhl; Elmegaard, Brian
2009-01-01
of the refrigerant distribution is carried out for two channels in parallel and for two different cases. In the first case maldistribution of the inlet quality into the channels is considered, and in the second case a non-uniform airflow on the secondary side is considered. In both cases the total mixed superheat...... out of the evaporator is kept constant. It is shown that the cooling capacity of the evaporator is reduced significantly, both in the case of unevenly distributed inlet quality and for the case of non-uniform airflow on the outside of the channels.......The effects of refrigerant maldistribution in parallel evaporator channels on the heat exchanger performance are investigated numerically. For this purpose a 1D steady state model of refrigerant R134a evaporating in a microchannel tube is built and validated against other evaporator models. A study...
The FEL-TNO uniform open systems model
Luiijf, H.A.M.; Overbeek, P.L.
1989-01-01
The FEL-TNO Uniform Open Systems Model is based upon the IS0/0SI Basic Reference Model and integrates operating systems, (OSI) networks, equipment and media into one single uniform nodel. Usage of the model stimulates the development of operating systen and network independent applications and puts
Flood field uniformity testing - effects of crystal hydration
International Nuclear Information System (INIS)
Dimcheva, M.; Sergieva, S.; Doldurova, M.; Jovanovska, A.
2012-01-01
The most basic and sensitive routine quality control (QC) of gamma camera is that of intrinsic flood-field uniformity. The routine QC test must be assessed daily and any nonuniformity must be eliminated before patient testing to eliminate artifacts and false positive or false-negative patient results. The purpose of this study was to compare uniformity analysis results for scintillation crystal hydration with symmetric and asymmetric energy window on the Siemens Symbia T2 SPECTCT camera. Integral and differential uniformity analysis was performed by placing a point source 99m Tc in front of the detector with removed collimator to measure the effect of correction matrix, a count rate and activity volume on intrinsic uniformity. A 15% energy window set symmetrically over the 99m Tc photo peak is equivalent to 140±10% keV or a window spanning 126-154 keV. The results, received from Detector 2 gave the following uniformity parameter values: Both asymmetric energy window images show clearly multiple focal spots due to crystal hydration: discrete hot spots in the asymmetric low window image and discrete cold spots in the asymmetric high window image. The above results are not seen yet on the symmetric window image. We had replaced Detector 2 in order to avoid spots become visible in flood images obtained with the clinical energy window. The uniformity of a gamma camera is maybe the most important parameter that expresses the quality of the camera's performance. Non uniform areas in the field of view can result in misdiagnosed patients and low quality of clinical services. (authors)
Distribution of dose within the body from a photon emitter present in an organ
International Nuclear Information System (INIS)
Snyder, W.S.; Ford, M.R.; Warner, G.G.
1977-01-01
A dosimetric system was developed which provides estimates of mean radiation dose to organs from photon sources distributed uniformly in one or more organs. Although the sources of photons are assumed to be distributed uniformly, it is not true that dose from these photons is uniformly distributed. In particular, when a source of photons is located in a particular organ, nearby tissues will be irradiated at doses which decrease markedly with distance from the source. The mean dose may give a poor approximation to the actual dose if the tissues over which dose is averaged are extensive, for example, the remainder of the body. A set of enveloping organs was devised for liver, lungs, etc., which give mean dose at distances from zero to one centimeter from the source organ, from one to two centimeters, etc. These can be used to yield estimates of the extent of inhomogeneity of the dose distribution from a source of photons located in the source organ
Statistical distributions of avalanche size and waiting times in an inter-sandpile cascade model
Batac, Rene; Longjas, Anthony; Monterola, Christopher
2012-02-01
Sandpile-based models have successfully shed light on key features of nonlinear relaxational processes in nature, particularly the occurrence of fat-tailed magnitude distributions and exponential return times, from simple local stress redistributions. In this work, we extend the existing sandpile paradigm into an inter-sandpile cascade, wherein the avalanches emanating from a uniformly-driven sandpile (first layer) is used to trigger the next (second layer), and so on, in a successive fashion. Statistical characterizations reveal that avalanche size distributions evolve from a power-law p(S)≈S-1.3 for the first layer to gamma distributions p(S)≈Sαexp(-S/S0) for layers far away from the uniformly driven sandpile. The resulting avalanche size statistics is found to be associated with the corresponding waiting time distribution, as explained in an accompanying analytic formulation. Interestingly, both the numerical and analytic models show good agreement with actual inventories of non-uniformly driven events in nature.
Li, Hongye; Wan, Hongdan; Zhang, Zuxing; Sun, Bing; Zhang, Lin
2016-10-01
This paper investigates optical properties of few-mode fiber with non-uniform refractive index, namely: the few mode fiber with U-shape refractive index and the two-mode and four-mode few-mode fiber with bent radius. Finite element method is used to analyze the mode distributions based on their non-uniform refractive index. Effective mode control can be achieved through these few mode fibers to achieve vector beam generation. Finally, reflection spectra of a few-mode fiber Bragg grating are calculated theoretically and then measured under different bending conditions. Experimental results are in good accordance with the theoretical ones. These few mode fibers show potential applications in generation of cylindrical vector beam both for optical lasing and sensing systems.
Xia, Yongfang; Shi, Junrui; Xu, Youning; Ma, Rui
2018-03-01
Filtration combustion (FC) is one style of porous media combustion with inert matrix, in which the combustion wave front propagates, only downstream or reciprocally. In this paper, we investigate the FC flame front inclinational instability of lean methane/air mixtures flowing through a packed bed as a combustion wave front perturbation of the initial preheating temperature non-uniformity is assumed. The predicted results show that the growth rate of the flame front inclinational angle is proportional to the magnitude of the initial preheating temperature difference. Additionally, depending on gas inlet gas velocity and equivalence ratio, it is demonstrated that increase of gas inlet gas velocity accelerates the FC wave front deformation, and the inclinational instability evolves faster at lower equivalence ratio. The development of the flame front inclinational angle may be regarded as a two-staged evolution, which includes rapid increase, and approaching maximum value of inclinational angle due to the quasi-steady condition of the combustion system. The hydrodynamic and thermal mechanisms of the FC inclinational instability are analyzed. Consequently, the local propagation velocity of the FC wave front is non-uniform to result in the development of inclinational angle at the first stage of rapid increase.
International Nuclear Information System (INIS)
Wang, Haiqiang; Wang, Penglu; Chen, Xiongbo; Wu, Zhongbiao
2017-01-01
Highlights: • VOSO_4 exhibited better synergistic effect with titanate nanotubes than NH_4VO_3. • Ion-exchange reaction occurs between VOSO_4 and titanate nanotubes. • Ion-exchange resulting in uniformly vanadium distribution on titanate nanotubes. • VOSO_4-based catalyst exhibited impressive SCR activity and alkaline resistance. - Abstract: In this work, protonated titanate nanotubes was performed as a potential useful support and different vanadium precursors (NH_4VO_3 and VOSO_4) were used to synthesize deNO_x catalysts. The results showed that VOSO_4 exhibited better synergistic effect with titanate nanotubes than NH_4VO_3, which was caused by the ion-exchange reaction. Then high loading content of vanadium, uniformly active phase distribution, better dispersion of vanadium, more acid sites, better V"5"+/V"4"+ redox cycles and superior oxygen mobility were achieved. Besides, VOSO_4-based titanate nanotubes catalysts also showed enhanced alkaline resistance than particles (P25) based catalysts. It was strongly associated with its abundant acid sites, large surface area, flexible redox cycles and oxygen transfer ability. For the loading on protonated titanate nanotubes, active metal with cation groups was better precursors than anion ones. V_2O_5/TNTs catalyst was a promising substitute for the commercial vanadium catalysts and the work conducted herein provided a useful idea to design uniformly active phase loaded catalyst.
Growth functions for some uniformly amenable groups
Directory of Open Access Journals (Sweden)
Dronka Janusz
2017-04-01
Full Text Available We present a simple constructive proof of the fact that every abelian discrete group is uniformly amenable. We improve the growth function obtained earlier and find the optimal growth function in a particular case. We also compute a growth function for some non-abelian uniformly amenable group.
International Nuclear Information System (INIS)
Zhang, Hualin; Donnelly, Eric D.; Strauss, Jonathan B.; Qi, Yujin
2016-01-01
the radiosensitive normal tissue depending on the cylinder size, treatment lengths, prescription depth, and dose as well. However, for a uniform cancer cell distribution, the EUDs were between 6.3 Gy × 4 and 7.1 Gy × 4, and the TRs were found to be between (1.4)"4 and (1.7)"4. For the uniformly interspersed cancer and radio-resistant normal cells, the TRs were less than 1. The two VCBT prescription regimens were found to be equivalent in terms of EUDs and TRs. Conclusions: HDR VCBT strongly favors cylindrical target volume with the cancer cell distribution following its dosimetric trend. Assuming a half-Gaussian distribution of cancer cells, the HDR VCBT provides a considerable radiobiological advantage over the external beam radiotherapy (EBRT) in terms of sparing more normal tissues while maintaining the same level of cancer cell killing. But for the uniform cancer cell distribution and radio-resistant normal tissue, the radiobiology outcome of the HDR VCBT does not show an advantage over the EBRT. This study strongly suggests that radiation therapy design should consider the cancer cell distribution inside the target volume in addition to the shape of target
Linking of uniform random polygons in confined spaces
International Nuclear Information System (INIS)
Arsuaga, J; Blackstone, T; Diao, Y; Karadayi, E; Saito, M
2007-01-01
In this paper, we study the topological entanglement of uniform random polygons in a confined space. We derive the formula for the mean squared linking number of such polygons. For a fixed simple closed curve in the confined space, we rigorously show that the linking probability between this curve and a uniform random polygon of n vertices is at least 1-O(1/√n). Our numerical study also indicates that the linking probability between two uniform random polygons (in a confined space), of m and n vertices respectively, is bounded below by 1-O(1/√(mn)). In particular, the linking probability between two uniform random polygons, both of n vertices, is bounded below by 1-O(1/n)
The influence of nonuniform micro-distribution of alpha emitter on microdosimetry in cells
International Nuclear Information System (INIS)
Tian Yuan; Zhang Liang'an; Dai Guangfu
2007-01-01
Objective: To study the influence of nonuniform micro-distribution of alpha emitter on cellular S values(in the radioimmunotherapy). Methods: Emission of alpha particles is randomly simulated by Monte Carlo method; the incident energy and exit energy are calculated with interpolation technique based on the relationship between range and energy of alpha particle and the analytical Continuous Slowing Down Approximation (CSDA) model. So energy deposited in the target area can be obtained. To take 213 Po as an example, cellular S values with various cell dimensions and possible micro-distributions of radioactivity are calculated, such as linear increase, linear decrease, exponential increase and exponential decrease. Results: S values from cell to cell of uniform distribution showed no difference with the Hamacher's results. S values of different micro-distributions are distinguishing with each other. It is indicated that different micro-distributions of radioactivity will result in significant change of average chord length of alpha particles traveling in the target area, as well as the change of average stopping power over the chord, which is primary reason for differences of S values. Conclusions: The nonuniform micro-distributions show remarkable influence on cellular S values and hence should be taken consideration in cellular absorbed dose estimation, especially in microdosimetry. (authors)
Automatic diagnosis and control of distributed solid state lighting systems
Dong, J.; van Driel, W.D.; Zhang, G.Q.
2011-01-01
This paper describes a new design concept of automatically diagnosing and compensating LED degradations in distributed solid state lighting (SSL) systems. A failed LED may significantly reduce the overall illumination level, and destroy the uniform illumination distribution achieved by a nominal
Barriers to Implementing a Single Joint Combat Camouflage Uniform
2017-12-01
opportunities, threats (SWOT), and political, economic, social, and technological (PEST) analyses; examines the requirements and role of each of the...SUBJECT TERMS ground combat uniform, combat camouflage uniform history , combat camouflage uniform pattern, camouflage pattern testing 15. NUMBER...methodology applies strengths, weaknesses, opportunities, threats (SWOT), and political, economic, social, and technological (PEST) analyses
Student Dress Codes and Uniforms. Research Brief
Johnston, Howard
2009-01-01
According to an Education Commission of the States "Policy Report", research on the effects of dress code and school uniform policies is inconclusive and mixed. Some researchers find positive effects; others claim no effects or only perceived effects. While no state has legislatively mandated the wearing of school uniforms, 28 states and…
50 CFR 510.9 - Uniform pay guidelines.
2010-10-01
... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Uniform pay guidelines. 510.9 Section 510... ACT § 510.9 Uniform pay guidelines. (a) Compensation of members and staff of, and consultants to the... accordance with guidelines established by the Director of the Office of Management and Budget pursuant to...
Uniformly accelerating charged particles. A threat to the equivalence principle
International Nuclear Information System (INIS)
Lyle, Stephen N.
2008-01-01
There has been a long debate about whether uniformly accelerated charges should radiate electromagnetic energy and how one should describe their worldline through a flat spacetime, i.e., whether the Lorentz-Dirac equation is right. There are related questions in curved spacetimes, e.g., do different varieties of equivalence principle apply to charged particles, and can a static charge in a static spacetime radiate electromagnetic energy? The problems with the LD equation in flat spacetime are spelt out in some detail here, and its extension to curved spacetime is discussed. Different equivalence principles are compared and some vindicated. The key papers are discussed in detail and many of their conclusions are significantly revised by the present solution. (orig.)
The influence of x-ray energy on lung dose uniformity in total-body irradiation
International Nuclear Information System (INIS)
Ekstrand, Kenneth; Greven, Kathryn; Wu Qingrong
1997-01-01
Purpose: In this study we examine the influence of x-ray energy on the uniformity of the dose within the lung in total-body irradiation treatments in which partial transmission blocks are used to control the lung dose. Methods and Materials: A solid water phantom with a cork insert to simulate a lung was irradiated by x-rays with energies of either 6, 10, or 18 MV. The source to phantom distance was 3.9 meters. The cork insert was either 10 cm wide or 6 cm wide. Partial transmission blocks with transmission factors of 50% were placed anterior to the cork insert. The blocks were either 8 or 4 cm in width. Kodak XV-2 film was placed in the midline of the phantom to record the dose. Midplane dose profiles were measured with a densitometer. Results: For the 10 cm wide cork insert the uniformity of the dose over 80% of the block width varied from 6.6% for the 6 MV x-rays to 12.2% for the 18 MV x-rays. For the 6 cm wide cork insert the uniformity was comparable for all three x-ray energies, but for 18 MV the central dose increased by 9.4% compared to the 10 cm wide insert. Conclusion: Many factors must be considered in optimizing the dose for total-body irradiation. This study suggests that for AP/PA techniques lung dose uniformity is superior with 6 MV irradiation. The blanket recommendation that the highest x-ray energy be used in TBI is not valid for all situations
On Uniformly finitely extensible Banach spaces
Castillo, Jesús M. F.; Ferenczi, Valentin; Moreno, Yolanda
2013-01-01
We continue the study of Uniformly Finitely Extensible Banach spaces (in short, UFO) initiated in Moreno-Plichko, \\emph{On automorphic Banach spaces}, Israel J. Math. 169 (2009) 29--45 and Castillo-Plichko, \\emph{Banach spaces in various positions.} J. Funct. Anal. 259 (2010) 2098-2138. We show that they have the Uniform Approximation Property of Pe\\l czy\\'nski and Rosenthal and are compactly extensible. We will also consider their connection with the automorphic space problem of Lindenstraus...
On the distribution of DDO galaxies
International Nuclear Information System (INIS)
Sharp, N.A.; Jones, B.J.T.; Jones, J.E.
1978-01-01
The distribution of DDO galaxies on the sky and their relationship to normal galaxies have been examined. The results appear to contradict the universality of the luminosity function for galaxies. They also indicate that DDO galaxies are preferentially found in the vicinity of normal galaxies, but not uniformly in that they tend to avoid clusters. This may be due to the dependence of distribution upon morphological type. (author)
Directory of Open Access Journals (Sweden)
Runjun Phookun
2013-04-01
Full Text Available The renewal process has been formulated on the basis of hazard rate of time between two consecutive occurrences of depressive episodes. The probabilistic analysis of depressive episodes can be performed under various forms of hazard rate viz. constant, linear etc. In this paper we are considering a particular form of hazard rate which is h(x=(b-x^- where b is a constant, x is the time between two consecutive episodes of depression. As a result time between two consecutive occurrences of depressive episodes follows uniform distribution in (a,b The distribution of range i.e. the difference between the longest and the shortest occurrence time to a depressive episode, and the expected number of depressive episodes in a random interval of time are obtained for the distribution under consideration. If the closed form of expression for the waiting time distribution is not available, then the Laplace transformation is used for the study of probabilistic analysis. Hazard rate of occurrence and expected number of depressive episodes have been presented graphically
22 CFR 214.42 - Uniform pay guidelines.
2010-04-01
... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Uniform pay guidelines. 214.42 Section 214.42... Advisory Committees § 214.42 Uniform pay guidelines. (a) A.I.D. follows OMB/CSC guidelines in section 11 of... experts, their compensation shall be fixed in accordance with CSC guidelines and regulations, and the...
Influence of ventilation structure on air flow distribution of large turbo-generator
Zhang, Liying; Ding, Shuye; Zhao, Zhijun; Yang, Jingmo
2018-04-01
For the 350 MW air - cooled turbo—generator, the rotor body is ventilated by sub -slots and 94 radial ventilation ducts and the end adopts arc segment and the straight section to acquire the wind. The stator is ventilated with five inlets and eight outlet air branches. In order to analyze the cooling effect of different ventilation schemes, a global physical model including the stator, rotor, casing and fan is established, and the assumptions and boundary conditions of the solution domain are given. the finite volume method is used to solve the problem, and the air flow distribution characteristics of each part of the motor under different ventilation schemes are obtained. The results show that the baffle at the end of the rotor can eliminate the eddy current at the end of the rotor, and make the flow distribution of cooling air more uniform and reasonable. The conclusions can provide reference for the design of motor ventilation structure.
Linking of uniform random polygons in confined spaces
Arsuaga, J.; Blackstone, T.; Diao, Y.; Karadayi, E.; Saito, M.
2007-03-01
In this paper, we study the topological entanglement of uniform random polygons in a confined space. We derive the formula for the mean squared linking number of such polygons. For a fixed simple closed curve in the confined space, we rigorously show that the linking probability between this curve and a uniform random polygon of n vertices is at least 1-O\\big(\\frac{1}{\\sqrt{n}}\\big) . Our numerical study also indicates that the linking probability between two uniform random polygons (in a confined space), of m and n vertices respectively, is bounded below by 1-O\\big(\\frac{1}{\\sqrt{mn}}\\big) . In particular, the linking probability between two uniform random polygons, both of n vertices, is bounded below by 1-O\\big(\\frac{1}{n}\\big) .
International Nuclear Information System (INIS)
Peters, V.G.
2000-01-01
Purpose: The vertex of the scalp is always tangentially irradiated during total skin electron therapy (TSET). This study was conducted to determine the dose distribution at the vertex for a commonly used irradiation technique and to evaluate the use of an electron reflector, positioned above the head, as a means of improving the dose uniformity. Methods and Materials: Phantoms, simulating the head of a patient, were irradiated using our standard procedure for TSET. The technique is a six-field irradiation using dual angled electron beams at a treatment distance of 3.6 meters. Vertex dosimetry was performed using ionization methods and film. Measurements were made for an unmodified 6 MeV electron beam and for a 4 MeV beam obtained by placing an acrylic scattering plate in the beam line. Studies were performed to examine the effect of electron scattering on vertex dose when a lead reflector, 50 x 50 cm in area, was positioned above the phantom. Results: The surface dose at the vertex, in the absence of the reflector, was found to be less than 40% of the prescribed skin dose. Use of the lead reflector increased this value to 73% for the 6 MeV beam and 99% for the degraded 4 MeV beam. Significant improvements in depth dose were also observed. The dose enhancement is not strongly dependent on reflector distance or angulation since the reflector acts as a large source of broadly scattered electrons. Conclusion: The vertex may be significantly underdosed using standard techniques for total skin electron therapy. Use of an electron reflector improves the dose uniformity at the vertex and may reduce or eliminate the need for supplemental irradiation
Adding muscle where you need it: non-uniform hypertrophy patterns in elite sprinters.
Handsfield, G G; Knaus, K R; Fiorentino, N M; Meyer, C H; Hart, J M; Blemker, S S
2017-10-01
Sprint runners achieve much higher gait velocities and accelerations than average humans, due in part to large forces generated by their lower limb muscles. Various factors have been explored in the past to understand sprint biomechanics, but the distribution of muscle volumes in the lower limb has not been investigated in elite sprinters. In this study, we used non-Cartesian MRI to determine muscle sizes in vivo in a group of 15 NCAA Division I sprinters. Normalizing muscle sizes by body size, we compared sprinter muscles to non-sprinter muscles, calculated Z-scores to determine non-uniformly large muscles in sprinters, assessed bilateral symmetry, and assessed gender differences in sprinters' muscles. While limb musculature per height-mass was 22% greater in sprinters than in non-sprinters, individual muscles were not all uniformly larger. Hip- and knee-crossing muscles were significantly larger among sprinters (mean difference: 30%, range: 19-54%) but only one ankle-crossing muscle was significantly larger (tibialis posterior, 28%). Population-wide asymmetry was not significant in the sprint population but individual muscle asymmetries exceeded 15%. Gender differences in normalized muscle sizes were not significant. The results of this study suggest that non-uniform hypertrophy patterns, particularly large hip and knee flexors and extensors, are advantageous for fast sprinting. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cold-Water Immersion for Hyperthermic Humans Wearing American Football Uniforms.
Miller, Kevin C; Swartz, Erik E; Long, Blaine C
2015-08-01
Current treatment recommendations for American football players with exertional heatstroke are to remove clothing and equipment and immerse the body in cold water. It is unknown if wearing a full American football uniform during cold-water immersion (CWI) impairs rectal temperature (Trec) cooling or exacerbates hypothermic afterdrop. To determine the time to cool Trec from 39.5°C to 38.0°C while participants wore a full American football uniform or control uniform during CWI and to determine the uniform's effect on Trec recovery postimmersion. Crossover study. Laboratory. A total of 18 hydrated, physically active, unacclimated men (age = 22 ± 3 years, height = 178.8 ± 6.8 cm, mass = 82.3 ± 12.6 kg, body fat = 13% ± 4%, body surface area = 2.0 ± 0.2 m(2)). Participants wore the control uniform (undergarments, shorts, crew socks, tennis shoes) or full uniform (control plus T-shirt; tennis shoes; jersey; game pants; padding over knees, thighs, and tailbone; helmet; and shoulder pads). They exercised (temperature approximately 40°C, relative humidity approximately 35%) until Trec reached 39.5°C. They removed their T-shirts and shoes and were then immersed in water (approximately 10°C) while wearing each uniform configuration; time to cool Trec to 38.0°C (in minutes) was recorded. We measured Trec (°C) every 5 minutes for 30 minutes after immersion. Time to cool from 39.5°C to 38.0°C and Trec. The Trec cooled to 38.0°C in 6.19 ± 2.02 minutes in full uniform and 8.49 ± 4.78 minutes in control uniform (t17 = -2.1, P = .03; effect size = 0.48) corresponding to cooling rates of 0.28°C·min(-1) ± 0.12°C·min(-1) in full uniform and 0.23°C·min(-1) ± 0.11°C·min(-1) in control uniform (t17 = 1.6, P = .07, effect size = 0.44). The Trec postimmersion recovery did not differ between conditions over time (F1,17 = 0.6, P = .59). We speculate that higher skin temperatures before CWI, less shivering, and greater conductive cooling explained the faster cooling
International Nuclear Information System (INIS)
Herve, Patrick
1975-01-01
This is a theoretical study of an electrically viscous fluid flowing in a straight rectangular cross section channel, a wall of which, infinitely conducting, is placed perpendicularly to the direction of a uniform magnetic induction field. The three other walls of the channel being electrically insulating, remain motionless. Formulas giving velocity distribution law in the straight section of the flow in relation to the Hartmann's number, curves illustrating the accelerating effect produced across the whole section, by the application of the magnetic induction field, and example for the distribution of the electric current lines in case of a square section are given [fr
Energy Technology Data Exchange (ETDEWEB)
Han, Seung Hak; Nam, Seok Ho; Lee, Je Yull; Song, Seung Hyun; Jeon, Hae Ryong; Baek, Geon Woo; Ko, Tae Kuk [Yonsei University, Seoul (Korea, Republic of); Kang, Hyoung Ku [Korea National University of Transportation, Chungju (Korea, Republic of)
2017-09-15
Current lead is a device that connects the power supply and superconducting magnets. High temperature superconductor (HTS) has lower thermal conductivity and higher current density than normal metal. For these reasons, the heat load can be reduced by replacing the normal metal of the current lead with the HTS. Conventional HTS current lead has same cross-sectional area in the axial direction. However, this is over-designed at the cold-end (4.2 K) in terms of current. The heat load can be reduced by reducing this part because the heat load is proportional to the cross-sectional area. Therefore, in this paper, heat load was calculated from the heat diffusion equation of HTS current leads with uniform and non-uniform cross-sectional areas. The cross-sectional area of the warm-end (65K) is designed considering burnout time when cooling system failure occurs. In cold-end, Joule heat and heat load due to current conduction occurs at the same time, so the cross-sectional area where the sum of the two heat is minimum is obtained. As a result of simulation, current leads for KSTAR TF coils with uniform and non-uniform cross-sectional areas were designed, and it was confirmed that the non-uniform cross-sectional areas could further reduce the heat load.
CFD analysis of flow distribution at the core inlet of SMART
Energy Technology Data Exchange (ETDEWEB)
Bae, Youngmin, E-mail: ybae@kaeri.re.kr [Korea Atomic Energy Research Institute, 150 Deokjin-dong, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Kim, Young In; Park, Cheon Tae [Korea Atomic Energy Research Institute, 150 Deokjin-dong, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)
2013-05-15
Highlights: ► Core inlet flow distribution of system-integrated modular advanced reactor (SMART) is numerically investigated. ► Effects of mesh resolution, turbulence model, Reynolds number, and inflow condition are examined. ► Numerical results show that lower core support plate effectively distributes the flow at the core inlet of SMART. -- Abstract: This study numerically investigates the flow distribution at the core inlet region of the system-integrated modular advanced reactor (SMART). The single-phase turbulent flow is computed by the commercial CFD code, Fluent 12.0 on the computational domain consisting of three main parts: fuel assemblies, a lower core support plate, and a flow skirt. Simulations are carried out with different mesh resolutions, turbulence models, and upstream boundary conditions. The CFD results show that the flow distribution at the core inlet is almost identical for the two Reynolds numbers and turbulence models tested here, and the effect of mesh refinement on the flow distribution at the core inlet is negligible. It is also found that under a uniform upstream boundary condition, the maximum difference in mass flow rate between the fuel assemblies is less than 2%, while it slightly increases to 2.3% under a non-uniform condition. These results consequently indicate that the present design of the lower core support plate effectively distributes the flow at the core inlet of SMART, even when the flow discharged from the upstream has a certain degree of non-uniformity.
Real-time definition of non-randomness in the distribution of genomic events.
Directory of Open Access Journals (Sweden)
Ulrich Abel
Full Text Available Features such as mutations or structural characteristics can be non-randomly or non-uniformly distributed within a genome. So far, computer simulations were required for statistical inferences on the distribution of sequence motifs. Here, we show that these analyses are possible using an analytical, mathematical approach. For the assessment of non-randomness, our calculations only require information including genome size, number of (sampled sequence motifs and distance parameters. We have developed computer programs evaluating our analytical formulas for the real-time determination of expected values and p-values. This approach permits a flexible cluster definition that can be applied to most effectively identify non-random or non-uniform sequence motif distribution. As an example, we show the effectivity and reliability of our mathematical approach in clinical retroviral vector integration site distribution.
The Ciliate Paramecium Shows Higher Motility in Non-Uniform Chemical Landscapes
Giuffre, Carl; Hinow, Peter; Vogel, Ryan; Ahmed, Tanvir; Stocker, Roman; Consi, Thomas R.; Strickler, J. Rudi
2011-01-01
We study the motility behavior of the unicellular protozoan Paramecium tetraurelia in a microfluidic device that can be prepared with a landscape of attracting or repelling chemicals. We investigate the spatial distribution of the positions of the individuals at different time points with methods from spatial statistics and Poisson random point fields. This makes quantitative the informal notion of “uniform distribution” (or lack thereof). Our device is characterized by the absence of large systematic biases due to gravitation and fluid flow. It has the potential to be applied to the study of other aquatic chemosensitive organisms as well. This may result in better diagnostic devices for environmental pollutants. PMID:21494596
Effect of Heterogeneity in Initial Geographic Distribution on Opinions’ Competitiveness
Directory of Open Access Journals (Sweden)
Alexander S. Balankin
2015-05-01
Full Text Available Spin dynamics on networks allows us to understand how a global consensus emerges out of individual opinions. Here, we are interested in the effect of heterogeneity in the initial geographic distribution of a competing opinion on the competitiveness of its own opinion. Accordingly, in this work, we studied the effect of spatial heterogeneity on the majority rule dynamics using a three-state spin model, in which one state is neutral. Monte Carlo simulations were performed on square lattices divided into square blocks (cells. Accordingly, one competing opinion was distributed uniformly among cells, whereas the spatial distribution of the rival opinion was varied from the uniform to heterogeneous, with the median-to-mean ratio in the range from 1 to 0. When the size of discussion group is odd, the uncommitted agents disappear completely after 3.30 ± 0.05 update cycles, and then the system evolves in a two-state regime with complementary spatial distributions of two competing opinions. Even so, the initial heterogeneity in the spatial distribution of one of the competing opinions causes a decrease of this opinion competitiveness. That is, the opinion with initially heterogeneous spatial distribution has less probability to win, than the opinion with the initially uniform spatial distribution, even when the initial concentrations of both opinions are equal. We found that although the time to consensus , the opinion’s recession rate is determined during the first 3.3 update cycles. On the other hand, we found that the initial heterogeneity of the opinion spatial distribution assists the formation of quasi-stable regions, in which this opinion is dominant. The results of Monte Carlo simulations are discussed with regard to the electoral competition of political parties.
International Nuclear Information System (INIS)
Higdon, J.C.; Schmidt, M.
1990-01-01
The V/Vmax test is applied to gamma-ray bursts of duration longer than 1 sec recorded by the Konus experiment, to examine quantitatively the uniformity of the burst source population. A sample of 123 bursts detected on Venera 11 and Venera 12, gives mean V/Vmax = 0.45 + or - 0.03, consistent with 0.5, the value expected for a uniform distribution in space of the parent population of burst sources. It is argued that experimenters give careful attention to the detection limit for each recorded gamma-ray burst, and that quantitative data for burst properties and detection limits should be published. 28 refs
Computer simulation of structures and distributions of particles in MAGIC fluid
International Nuclear Information System (INIS)
Zhu Yongsheng; Umehara, Noritsugu; Ido, Yasushi; Sato, Atsushi
2006-01-01
MAGIC (MAG-netic Intelligent Compound) is a solidified magnetic ferrofluid (MF) containing both magnetic particles (MPs) and abrasive particles (APs, nonmagnetic) of micron size. The distribution of APs in MAGIC can be controlled by applying a magnetic field during cooling process of MAGIC fluid. In this paper, the influences of magnetic field, size and concentration of particles on the final structures of MPs and the distributions of APs in MAGIC fluid are preliminarily investigated using Stokesian dynamic (SD) simulation method. Simulation results show that MPs prefer to form strip-like structures in MAGIC fluid, the reason for this phenomenon is mainly attributed to the strong dipolar interactions between them. It is also found that MPs prefer to form big agglomerations in weak magnetic field while chains and strip-like structures in strong magnetic field; no long chains or strip-like structures of MPs are observed in low-concentration MAGIC fluid; and for big-size MPs, pure wall-like structures are formed. Evaluation on the distribution of APs with uniformity coefficient shows that strong magnetic field, high concentration and small-size particles can induce more uniform distribution of APs in MAGIC fluid, the uniformity of APs in MAGIC is about 10% higher than that in normal grinding tools
Analysis of stationary power/amplitude distributions for multiple channels of sampled FBGs.
Xing, Ya; Zou, Xihua; Pan, Wei; Yan, Lianshan; Luo, Bin; Shao, Liyang
2015-08-10
Stationary power/amplitude distributions for multiple channels of the sampled fiber Bragg grating (SFBG) along the grating length are analyzed. Unlike a uniform FBG, the SFBG has multiple channels in the reflection spectrum, not a single channel. Thus, the stationary power/amplitude distributions for these multiple channels are analyzed by using two different theoretical models. In the first model, the SFBG is regarded as a set of grating sections and non-grating sections, which are alternately stacked. A step-like distribution is obtained for the corresponding power/amplitude of each channel along the grating length. While, in the second model, the SFBG is decomposed into multiple uniform "ghost" gratings, and a continuous distribution is obtained for each ghost grating (i.e., each channel). After a comparison, the distributions obtained in the two models are identical, and the equivalence between the two models is demonstrated. In addition, the impacts of the duty cycle on the power/amplitude distributions of multiple channels of SFBG are presented.
Non-Uniformity Correction Using Nonlinear Characteristic Performance Curves for Calibration
Lovejoy, McKenna Roberts
Infrared imaging is an expansive field with many applications. Advances in infrared technology have lead to a greater demand from both commercial and military sectors. However, a known problem with infrared imaging is its non-uniformity. This non-uniformity stems from the fact that each pixel in an infrared focal plane array has its own photoresponse. Many factors such as exposure time, temperature, and amplifier choice affect how the pixels respond to incoming illumination and thus impact image uniformity. To improve performance non-uniformity correction (NUC) techniques are applied. Standard calibration based techniques commonly use a linear model to approximate the nonlinear response. This often leaves unacceptable levels of residual non-uniformity. Calibration techniques often have to be repeated during use to continually correct the image. In this dissertation alternates to linear NUC algorithms are investigated. The goal of this dissertation is to determine and compare nonlinear non-uniformity correction algorithms. Ideally the results will provide better NUC performance resulting in less residual non-uniformity as well as reduce the need for recalibration. This dissertation will consider new approaches to nonlinear NUC such as higher order polynomials and exponentials. More specifically, a new gain equalization algorithm has been developed. The various nonlinear non-uniformity correction algorithms will be compared with common linear non-uniformity correction algorithms. Performance will be compared based on RMS errors, residual non-uniformity, and the impact quantization has on correction. Performance will be improved by identifying and replacing bad pixels prior to correction. Two bad pixel identification and replacement techniques will be investigated and compared. Performance will be presented in the form of simulation results as well as before and after images taken with short wave infrared cameras. The initial results show, using a third order
Uniformly irradiated polymer film
International Nuclear Information System (INIS)
Fowler, S.L.
1979-01-01
Irradiated film having substantial uniformity in the radiation dosage profile is produced by irradiating the film within a trough having lateral deflection blocks disposed adjacent the film edges for deflecting electrons toward the surface of the trough bottom for further deflecting the electrons toward the film edge
Sequence-indexed mutations in maize using the UniformMu transposon-tagging population
Directory of Open Access Journals (Sweden)
Baier John
2007-05-01
Full Text Available Abstract Background Gene knockouts are a critical resource for functional genomics. In Arabidopsis, comprehensive knockout collections were generated by amplifying and sequencing genomic DNA flanking insertion mutants. These Flanking Sequence Tags (FSTs map each mutant to a specific locus within the genome. In maize, FSTs have been generated using DNA transposons. Transposable elements can generate unstable insertions that are difficult to analyze for simple knockout phenotypes. Transposons can also generate somatic insertions that fail to segregate in subsequent generations. Results Transposon insertion sites from 106 UniformMu FSTs were tested for inheritance by locus-specific PCR. We confirmed 89% of the FSTs to be germinal transposon insertions. We found no evidence for somatic insertions within the 11% of insertion sites that were not confirmed. Instead, this subset of insertion sites had errors in locus-specific primer design due to incomplete or low-quality genomic sequences. The locus-specific PCR assays identified a knockout of a 6-phosphogluconate dehydrogenase gene that co-segregates with a seed mutant phenotype. The mutant phenotype linked to this knockout generates novel hypotheses about the role for the plastid-localized oxidative pentose phosphate pathway during grain-fill. Conclusion We show that FSTs from the UniformMu population identify stable, germinal insertion sites in maize. Moreover, we show that these sequence-indexed mutations can be readily used for reverse genetic analysis. We conclude from these data that the current collection of 1,882 non-redundant insertion sites from UniformMu provide a genome-wide resource for reverse genetics.
Laser investigation of the non-uniformity of fluorescent species in dental enamel
Tran, Stephanie U.; Ridge, Jeremy S.; Nelson, Leonard Y.; Seibel, Eric J.
In the present study, artificial type I and type II erosions were created on dental specimen using acetic acid and EDTA respectively. Specimens were prepared by etching extracted teeth samples in acid to varying degrees, after which the absolute fluorescence intensity ratio of the etched enamel relative to sound enamel was recorded for each specimen using 405 and 532 nm laser excitation. Results showed differences in the fluorescence ratio of etched to sound enamel for type I and II erosions. These findings suggest a non-uniform distribution of fluorescent species in the interprismatic region as compared to the prismatic region.
Uniform color space is not homogeneous
Kuehni, Rolf G.
2002-06-01
Historical data of chroma scaling and hue scaling are compared and evidence is shown that we do not have a reliable basis in either case. Several data sets indicate explicitly or implicitly that the number of constant sized hue differences between unique hues as well as in the quadrants of the a*, b* diagram differs making what is commonly regarded as uniform color space inhomogeneous. This problem is also shown to affect the OSA-UCS space. A Euclidean uniform psychological or psychophysical color space appears to be impossible.
75 FR 78155 - Uniform Compliance Date for Food Labeling Regulations
2010-12-15
.... FDA-2000-N-0011] Uniform Compliance Date for Food Labeling Regulations AGENCY: Food and Drug... 1, 2014, as the uniform compliance date for food labeling regulations that are issued between... established January 2, 2012, as the uniform compliance date for food labeling regulations issued between...
International Nuclear Information System (INIS)
Shen Pei; Zhang Wanrong; Huang Lu; Jin Dongyue; Xie Hongyun
2011-01-01
An improved inductor layout with non-uniform metal width and non-uniform spacing is proposed to increase the quality factor (Q factor). For this inductor layout, from outer coil to inner coil, the metal width is reduced by an arithmetic-progression step, while the metal spacing is increased by a geometric-progression step. An improved layout with variable width and changed spacing is of benefit to the Q factor of RF spiral inductor improvement (approximately 42.86%), mainly due to the suppression of eddy-current loss by weakening the current crowding effect in the center of the spiral inductor. In order to increase the Q factor further, for the novel inductor, a patterned ground shield is used with optimized layout together. The results indicate that, in the range of 0.5 to 16 GHz, the Q factor of the novel inductor is at an optimum, which improves by 67% more than conventional inductors with uniform geometry dimensions (equal width and equal spacing), is enhanced by nearly 23% more than a PGS inductor with uniform geometry dimensions, and improves by almost 20% more than an inductor with an improved layout. (semiconductor devices)
77 FR 70885 - Uniform Compliance Date for Food Labeling Regulations
2012-11-28
.... FDA-2000-N-0011] Uniform Compliance Date for Food Labeling Regulations AGENCY: Food and Drug... January 1, 2016, as the uniform compliance date for food labeling regulations that are issued between... established January 1, 2014, as the uniform compliance date for food labeling regulations issued between...
International Nuclear Information System (INIS)
Miller, G.; Martz, H.; Bertelli, L.; Melo, D.
2008-01-01
A simplified biokinetic model for 137 Cs has six parameters representing transfer of material to and from various compartments. Using a Bayesian analysis, the joint probability distribution of these six parameters is determined empirically for two cases with quite a lot of bioassay data. The distribution is found to be a multivariate log-normal. Correlations between different parameters are obtained. The method utilises a fairly large number of pre-determined forward biokinetic calculations, whose results are stored in interpolation tables. Four different methods to sample the multidimensional parameter space with a limited number of samples are investigated: random, stratified, Latin Hypercube sampling with a uniform distribution of parameters and importance sampling using a lognormal distribution that approximates the posterior distribution. The importance sampling method gives much smaller sampling uncertainty. No sampling method-dependent differences are perceptible for the uniform distribution methods. (authors)
A non-uniform expansion mechanical safety model of the stent.
Yang, J; Huang, N; Du, Q
2009-01-01
Stents have a serial unstable structure that readily leads to non-uniform expansion. Non-uniform expansion in turn creates a stent safety problem. We explain how a stent may be simplified to a serial unstable structure, and present a method to calculate the non-uniform expansion of the stent on the basis of the serial unstable structure. We propose a safety criterion based on the expansion displacement instead of the strain, and explain that the parameter Rd, the ratio of the maximum displacement of the elements to normal displacement, is meaningful to assess the safety level of the stent. We also examine how laser cutting influences non-uniform expansion. The examples illustrate how to calculate the parameter Rd to assess non-uniform expansion of the stent, and demonstrate how the laser cutting offset and strengthening coefficient of the material influence the stent expansion behaviour. The methods are valuable for assessing stent safety due to non-uniform expansion.
Performance of water distribution systems in a pilot cooling tower
International Nuclear Information System (INIS)
Tognotti, L.; Giacomelli, A.; Zanelli, S.; Bellagamba, B.; Lotti, G.; Mattachini, F.
1990-01-01
An experimental study has been carried out on the water distribution system of a Pilot cooling tower of 160 m 3 /hr The performances of different industrial water distributors have been evaluated by changing the operative conditions of the pilot tower. In particular, the efficiency and the uniformity of the water distribution have been investigated and compared with the results obtained in a small-scale loop, in which the single nozzles were tested. Measurements in both systems, pilot tower and small scale loop, included the geometric characteristics of the jet umbrella by ensemble photography, the wetted zone by measuring the specific flowrate, the drop-size distribution and liquid concentration by high-speed photography. The results show that correlations exist between the nozzle behaviour in single and pilot tower configuration. The uniformity of water distribution in the pilot tower is strongly related to the nozzle installation pattern and to the operative conditions. Coalescence plays an important role on the drop size distribution in the pilot-tower. Comments upon the influence of these parameters on tower behaviour are also included
Vertical uniformity of cells and nuclei in epithelial monolayers.
Neelam, Srujana; Hayes, Peter Robert; Zhang, Qiao; Dickinson, Richard B; Lele, Tanmay P
2016-01-22
Morphological variability in cytoskeletal organization, organelle position and cell boundaries is a common feature of cultured cells. Remarkable uniformity and reproducibility in structure can be accomplished by providing cells with defined geometric cues. Cells in tissues can also self-organize in the absence of directing extracellular cues; however the mechanical principles for such self-organization are not understood. We report that unlike horizontal shapes, the vertical shapes of the cell and nucleus in the z-dimension are uniform in cells in cultured monolayers compared to isolated cells. Apical surfaces of cells and their nuclei in monolayers were flat and heights were uniform. In contrast, isolated cells, or cells with disrupted cell-cell adhesions had nuclei with curved apical surfaces and variable heights. Isolated cells cultured within micron-sized square wells displayed flat cell and nuclear shapes similar to cells in monolayers. Local disruption of nuclear-cytoskeletal linkages resulted in spatial variation in vertical uniformity. These results suggest that competition between cell-cell pulling forces that expand and shorten the vertical cell cross-section, thereby widening and flattening the nucleus, and the resistance of the nucleus to further flattening results in uniform cell and nuclear cross-sections. Our results reveal the mechanical principles of self-organized vertical uniformity in cell monolayers.
Conclusions and recommendations
International Nuclear Information System (INIS)
Carrette, M.
1997-01-01
The paper presents conclusions and recommendations at the closing session of the NEA/OECD Workshop held at Fontenay-aux-Roses on 12-14 June 1995. The conclusions refer to issues like: public reaction to foodstuffs containing radioisotope concentrations under the danger standards, possible non-adherence of manufacturers, processors, distributors, et al, to the instructions and guidance from radiation protection specialists, integration of all the food chain factors in the elaboration of the emergency intervention programs, etc. Among the most significant recommendations the following may be mentioned: 1. Differences between different intervention levels and the maximum admissible levels agreed upon by national, regional or international nutrition authorities should be further studied; 2. Problems created by the Chernobyl accident (as for instance, the methods of treatment of food chain products containing unacceptable radioactivity concentrations) are still present and must be solved; 3. Further studies should be done on the socio-cultural aspects of the communication, particularly on the information in rural environment; 4. The preventive measures in agriculture should be implemented as rapidly as possible; 5. In elaborating programmes of agriculture countermeasures, the management of contaminated media, particularly, of forests and their effect on agriculture
2008-11-13
ABSTRACT (Maximum 200 Words) The DLA and DSCP sponsored Customer Driven Uniform Manufacturing (CDUM) program’s primary goals are to reduce total...functions that make decisions or consume apparel items. PDIT’s CDUM assignments were to create the web accessible database, create decision support tools...Manufacturing Monitoring Processes ....................................................40 Figure 32 – Assign Contract to Buyer
Ultra-broadband and planar sound diffuser with high uniformity of reflected intensity
Fan, Xu-Dong; Zhu, Yi-Fan; Liang, Bin; Yang, Jing; Yang, Jun; Cheng, Jian-Chun
2017-09-01
Schroeder diffusers, as a classical design of acoustic diffusers proposed over 40 years ago, play key roles in many practical scenarios ranging from architectural acoustics to noise control to particle manipulation. Despite the great success of conventional acoustic diffusers, it is still worth pursuing ideal acoustic diffusers that are essentially expected to produce perfect sound diffuse reflection within the unlimited bandwidth. Here, we propose a different mechanism for designing acoustic diffusers to overcome the basic limits in intensity uniformity and working bandwidth in the previous designs and demonstrate a practical implementation by acoustic metamaterials with dispersionless phase-steering capability. In stark contrast to the existing production of diffuse fields relying on random scattering of sound energy by using a specific mathematical number sequence of periodically distributed unit cells, we directly mold the reflected wavefront into the desired shape by precisely manipulating the local phases of individual subwavelength metastructures. We also benchmark our design via numerical simulation with a commercially available Schroeder diffuser, and the results verify that our proposed diffuser scatters incident acoustic energy into all directions more uniformly within an ultra-broad band regardless of the incident angle. Furthermore, our design enables further improvement of the working bandwidth just by simply downscaling each individual element. With ultra-broadband functionality and high uniformity of reflected intensity, our metamaterial-based production of the diffusive field opens a route to the design and application of acoustic diffusers and may have a significant impact on various fields such as architectural acoustics and medical ultrasound imaging/treatment.
International Nuclear Information System (INIS)
Ikegawa, Masato; Kobayashi, Jun'ichi; Fukuyama, Ryoji
2001-01-01
To achieve high etch rate, uniformity, good selectivity, and etch profile control across large diameter wafers, the distributions of ions, radicals, and etch products in magnetomicrowave high-etch-rate plasma etching reactors must be accurately controlled. In this work the effects of chamber heights, a focus ring around the wafer, and gas supply structures (or gas flow structures) on the radicals and etch products flux distribution onto the wafer were examined using the direct simulation Monte Carlo method and used to determine the optimal reactor geometry. The pressure uniformity on the wafer was less than ±1% when the chamber height was taller than 60 mm. The focus ring around the wafer produced uniform radical and etch-product fluxes but increased the etch-product flux on the wafer. A downward-flow gas-supply structure (type II) produced a more uniform radical distribution than that produced by a radial gas-supply structure (type I). The impact flow of the type II structure removed etch products from the wafer effectively and produced a uniform etch-product distribution even without the focus ring. Thus the downward-flow gas-supply structure (type II) was adopted in the design for the second-generation of a magnetomicrowave plasma etching reactor with a higher etching rate
Chen, Xiaowei; Wang, Wenping; Wan, Min
2013-12-01
It is essential to calculate magnetic force in the process of studying electromagnetic flat sheet forming. Calculating magnetic force is the basis of analyzing the sheet deformation and optimizing technical parameters. Magnetic force distribution on the sheet can be obtained by numerical simulation of electromagnetic field. In contrast to other computing methods, the method of numerical simulation has some significant advantages, such as higher calculation accuracy, easier using and other advantages. In this paper, in order to study of magnetic force distribution on the small size flat sheet in electromagnetic forming when flat round spiral coil, flat rectangular spiral coil and uniform pressure coil are adopted, the 3D finite element models are established by software ANSYS/EMAG. The magnetic force distribution on the sheet are analyzed when the plane geometries of sheet are equal or less than the coil geometries under fixed discharge impulse. The results showed that when the physical dimensions of sheet are less than the corresponding dimensions of the coil, the variation of induced current channel width on the sheet will cause induced current crowding effect that seriously influence the magnetic force distribution, and the degree of inhomogeneity of magnetic force distribution is increase nearly linearly with the variation of induced current channel width; the small size uniform pressure coil will produce approximately uniform magnetic force distribution on the sheet, but the coil is easy to early failure; the desirable magnetic force distribution can be achieved when the unilateral placed flat rectangular spiral coil is adopted, and this program can be take as preferred one, because the longevity of flat rectangular spiral coil is longer than the working life of small size uniform pressure coil.
Non-uniform velocity profile mechanism for flame stabilization in a porous radiant burner
Energy Technology Data Exchange (ETDEWEB)
Catapan, R.C.; Costa, M. [Mechanical Engineering Department, Instituto Superior Tecnico, Technical University of Lisbon, Avenida Rovisco Pais, 1049-001 Lisbon (Portugal); Oliveira, A.A.M. [Mechanical Engineering Department, Federal University of Santa Catarina, Campus Universitario Professor Joao David Ferreira Lima, 88040-900 Florianopolis, SC (Brazil)
2011-01-15
Industrial processes where the heating of large surfaces is required lead to the possibility of using large surface porous radiant burners. This causes additional temperature uniformity problems, since it is increasingly difficult to evenly distribute the reactant mixture over a large burner surface while retaining its stability and keeping low pollutant emissions. In order to allow for larger surface area burners, a non-uniform velocity profile mechanism for flame stabilization in a porous radiant burner using a single large injection hole is proposed and analyzed for a double-layered burner operating in open and closed hot (laboratory-scale furnace, with temperature-controlled, isothermal walls) environments. In both environments, local mean temperatures within the porous medium have been measured. For lower reactant flow rate and ambient temperature the flame shape is conical and anchored at the rim of the injection hole. As the volumetric flow rate or furnace temperature is raised, the flame undergoes a transition to a plane flame stabilized near the external burner surface. However, the stability range envelope remains the same in both regimes. (author)
Uniform emergency codes: will they improve safety?
2005-01-01
There are pros and cons to uniform code systems, according to emergency medicine experts. Uniformity can be a benefit when ED nurses and other staff work at several facilities. It's critical that your staff understand not only what the codes stand for, but what they must do when codes are called. If your state institutes a new system, be sure to hold regular drills to familiarize your ED staff.
Restricting uniformly open surjections
Czech Academy of Sciences Publication Activity Database
Kania, Tomasz; Rmoutil, M.
2017-01-01
Roč. 355, č. 9 (2017), s. 925-928 ISSN 1631-073X Institutional support: RVO:67985840 Keywords : Banach space * uniform spaces Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.396, year: 2016 http://www.sciencedirect.com/science/article/pii/S1631073X17302261?via%3Dihub
Transient well flow in layered aquifer systems: the uniform well-face drawdown solution
Hemker, C. J.
1999-11-01
Previously a hybrid analytical-numerical solution for the general problem of computing transient well flow in vertically heterogeneous aquifers was proposed by the author. The radial component of flow was treated analytically, while the finite-difference technique was used for the vertical flow component only. In the present work the hybrid solution has been modified by replacing the previously assumed uniform well-face gradient (UWG) boundary condition in such a way that the drawdown remains uniform along the well screen. The resulting uniform well-face drawdown (UWD) solution also includes the effects of a finite diameter well, wellbore storage and a thin skin, while partial penetration and vertical heterogeneity are accommodated by the one-dimensional discretization. Solutions are proposed for well flow caused by constant, variable and slug discharges. The model was verified by comparing wellbore drawdowns and well-face flux distributions with published numerical solutions. Differences between UWG and UWD well flow will occur in all situations with vertical flow components near the well, which is demonstrated by considering: (1) partially penetrating wells in confined aquifers, (2) fully penetrating wells in unconfined aquifers with delayed response and (3) layered aquifers and leaky multiaquifer systems. The presented solution can be a powerful tool for solving many well-hydraulic problems, including well tests, flowmeter tests, slug tests and pumping tests. A computer program for the analysis of pumping tests, based on the hybrid analytical-numerical technique and UWG or UWD conditions, is available from the author.
7 CFR 51.1447 - Fairly uniform in color.
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Fairly uniform in color. 51.1447 Section 51.1447... color. Fairly uniform in color means that 90 percent or more of the kernels in the lot have skin color within the range of one or two color classifications. ...
7 CFR 51.1407 - Fairly uniform in color.
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Fairly uniform in color. 51.1407 Section 51.1407 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... in color. Fairly uniform in color means that the shells do not show sufficient variation in color to...
Stress distributions of coils for toroidal magnetic field
International Nuclear Information System (INIS)
Kajita, Tateo; Miyamoto, Kenro.
1976-01-01
The stress distributions of a D shaped coil and a circular coil are computed by the finite element method. The dependences of the stress distribution on the geometrical parameters of the stress distribution on the geometrical parameters of the coils and supporting methods are examined. The maximum amount of the stress in the D shaped coil is not much smaller than that of the circular one. However, the stress distribution of the D shaped coil becomes much more uniform. The supporting method has as much effect as the geometrical parameters of the coil on the stress distribution. (auth.)
Koudela, Jindřich
2014-01-01
This work describes a practical and easy way to grasp the steps that must be taken at state (public) elementary school in implementing school uniforms, which are becoming essential tool changes the quality of school culture. Also briefly summarizes the theoretical background and the history of school uniforms not only in Czech Republic but in part also abroad. Submitted known reasons for and against the introduction of school uniforms in elementary schools. It gives examples of public opinion...
Tumor and normal tissue responses to fractioned non-uniform dose delivery
Energy Technology Data Exchange (ETDEWEB)
Kaellman, P; Aegren, A; Brahme, A [Karolinska Inst., Stockholm (Sweden). Dept. of Radiation Physics
1996-08-01
The volume dependence of the radiation response of a tumor is straight forward to quantify because it depends primarily on the eradication of all its clonogenic cells. A tumor therefore has a parallel organization as any surviving clonogen in principle can repopulate the tumor. The difficulty with the response of the tumor is instead to know the density and sensitivity distribution of the most resistant clonogenic cells. The increase in the 50% tumor control dose and the decrease in the maximum normalized slope of the dose response relation, {gamma}, in presence of small compartments of resistant tumor cells have therefore been quantified to describe their influence on the dose response relation. Injury to normal tissue is a much more complex and gradual process. It depends on earlier effects induced long before depletion of the differentiated and clonogenic cells that in addition may have a complex structural and functional organization. The volume dependence of the dose response relation of normal tissues is therefore described here by the relative seriality, s, of the infrastructure of the organ. The model can also be generalized to describe the response of heterogeneous tissues to non uniform dose distributions. The new model is compared with clinical and experimental data on normal tissue response, and shows good agreement both with regard to the shape of dose response relation and the volume dependence of the isoeffect dose. The response of tumors and normal tissues are quantified for arbitrary dose fractionations using the linear quadratic cell survival parameters {alpha} and {beta}. The parameters of the dose response relation are derived both for a constant dose per fraction and a constant number of dose fractions, thus in the latter case accounting also for non uniform dose delivery. (author). 26 refs, 4 figs.
International Nuclear Information System (INIS)
Thieke, Christian; Bortfeld, Thomas; Niemierko, Andrzej; Nill, Simeon
2003-01-01
Optimization algorithms in inverse radiotherapy planning need information about the desired dose distribution. Usually the planner defines physical dose constraints for each structure of the treatment plan, either in form of minimum and maximum doses or as dose-volume constraints. The concept of equivalent uniform dose (EUD) was designed to describe dose distributions with a higher clinical relevance. In this paper, we present a method to consider the EUD as an optimization constraint by using the method of projections onto convex sets (POCS). In each iteration of the optimization loop, for the actual dose distribution of an organ that violates an EUD constraint a new dose distribution is calculated that satisfies the EUD constraint, leading to voxel-based physical dose constraints. The new dose distribution is found by projecting the current one onto the convex set of all dose distributions fulfilling the EUD constraint. The algorithm is easy to integrate into existing inverse planning systems, and it allows the planner to choose between physical and EUD constraints separately for each structure. A clinical case of a head and neck tumor is optimized using three different sets of constraints: physical constraints for all structures, physical constraints for the target and EUD constraints for the organs at risk, and EUD constraints for all structures. The results show that the POCS method converges stable and given EUD constraints are reached closely
Below-threshold harmonic generation from strong non-uniform fields
Yavuz, I.
2017-10-01
Strong-field photoemission below the ionization threshold is a rich/complex region where atomic emission and harmonic generation may coexist. We studied the mechanism of below-threshold harmonics (BTH) from spatially non-uniform local fields near the metallic nanostructures. Discrete harmonics are generated due to the broken inversion symmetry, suggesting enriched coherent emission in the vuv frequency range. Through the numerical solution of the time-dependent Schrödinger equation, we investigate wavelength and intensity dependence of BTH. Wavelength dependence identifies counter-regular resonances; individual contributions from the multi-photon emission and channel-closing effects due to quantum path interferences. In order to understand the underlying mechanism of BTH, we devised a generalized semi-classical model, including the influence of Coulomb and non-uniform field interactions. As in uniform fields, Coulomb potential in non-uniform fields is the determinant of BTH; we observed that the generation of BTH are due to returning trajectories with negative energies. Due to large distance effectiveness of the non-uniformity, only long trajectories are noticeably affected.
Random distribution of nucleoli in metabolic cells
Energy Technology Data Exchange (ETDEWEB)
Beckman, R.J.; Waterman, M.S.
1977-01-01
Hasofer (1974) has studied a probabilistic model for the fusion of nucleoli in metabolic cells. The nucleoli are uniformly distributed at points in the nucleus, assumed to be a sphere. The nucleoli grow from a point to a maximum size during interphase, and fusion is said to occur if the nucleoli touch. For this model, Hasofer calculated the probability of fusion and found it much smaller than experimental data would indicate. Experimental data of this type is taken by use of a microscope where a two-dimensional view or projection of the three-dimensional cell is obtained. Hasofer implicitly assumes that actual fusion can be distinguished from the case where the two nucleoli do not touch but their two-dimensional projections overlap. It is assumed, in this letter, that these two cases cannot be distinguished. The probability obtained by Beckman and Waterman is larger than Hasofer's and a much better fit to the experimental data is obtained. Even if true fusion can be unfailingly distinguished from overlap of the two-dimensional projections, it is hoped that these calculations will allow someone to propose the correct (non-uniform) model. It is concluded, for the assumptions used, that there is not sufficient evidence to reject the hypothesis of uniform distribution of the nucleoli.
International Nuclear Information System (INIS)
Bhattacharyya Krishnendu
2013-01-01
In this paper, the effect of non-uniform heat flux on heat transfer in boundary layer stagnation-point flow over a shrinking sheet is studied. The variable boundary heat fluxes are considered of two types: direct power-law variation with the distance along the sheet and inverse power-law variation with the distance. The governing partial differential equations (PDEs) are transformed into non linear self-similar ordinary differential equations (ODEs) by similarity transformations, and then those are solved using very efficient shooting method. The direct variation and inverse variation of heat flux along the sheet have completely different effects on the temperature distribution. Moreover, the heat transfer characteristics in the presence of non-uniform heat flux for several values of physical parameters are also found to be interesting
DEFF Research Database (Denmark)
Melikov, Arsen Krikor
2011-01-01
The aim of total volume air distribution (TVAD) involves achieving uniform temperature and velocity in the occupied zone and environment designed for an average occupant. The supply of large amounts of clean and cool air are needed to maintain temperature and pollution concentration at acceptable...... levels in the entire space, leading to increased energy consumption and the use of large and costly HVAC and duct systems. The performance of desk installed PV combined with background TVAD used for room temperature control has been studied in an office building located in a hot and humid climate....... Ventilation in hospitals is essential to decrease the risk of airborne cross-infection. At present, mixing air distribution at a minimum of 12 ach is used in infection wards. Advanced air distribution has the potential to aid in achieving healthy, comfortable and productive indoor environments at levels...
A Program to Generate a Particle Distribution from Emittance Measurements
Bouma, DS; Lallement, JB
2010-01-01
We have written a program to generate a particle distribution based on emittance measurements in x-x’ and y-y’. The accuracy of this program has been tested using real and constructed emittance measurements. Based on these tests, the distribution generated by the program can be used to accurately simulate the beam in multi-particle tracking codes, as an alternative to a Gaussian or uniform distribution.
Directory of Open Access Journals (Sweden)
Thomas J. Dean
2018-06-01
Full Text Available According to the uniform-stress principle of stem formation, the amount of leaf area a tree carries and the leverage it exerts on the stem determine the stem dimensions. Within an even-aged monoculture, the leaf area per tree and the leverage placed on the stem are functions of tree density and tree height. The uniform-stress principle presents the means to translate density effects on crown characteristics into stem dimensions and total standing volume. This approach is truly a top-down method of simulating growth tree and stand growth because leaf area and other crown properties must be determined before stem size and taper can be calculated. Each crown property influences either the sail area or the leverage placed on the stem, but the degree to which a specific crown property affects these parameters changes with stand density and height. Leverage is the more complicated of the two variables, being a function of the height to the base of the live crown and the vertical distribution of leaf area. The purpose of this brief review is to summarize the effects of stand density on the height to the base of the live tree and the vertical distribution of leaf area and the various ways these variables have been quantified.
Shape and fission instabilities of ferrofluids in non-uniform magnetic fields
Vieu, Thibault; Walter, Clément
2018-04-01
We study static distributions of ferrofluid submitted to non-uniform magnetic fields. We show how the normal-field instability is modified in the presence of a weak magnetic field gradient. Then we consider a ferrofluid droplet and show how the gradient affects its shape. A rich phase transitions phenomenology is found. We also investigate the creation of droplets by successive splits when a magnet is vertically approached from below and derive theoretical expressions which are solved numerically to obtain the number of droplets and their aspect ratio as function of the field configuration. A quantitative comparison is performed with previous experimental results, as well as with our own experiments, and yields good agreement with the theoretical modeling.
The effect of the volumetric heat source distribution of the fuel pellet on the minimum DNBR ratio
International Nuclear Information System (INIS)
Hordosy, G.; Kereszturi, A.; Maroti, L.; Trosztel, I.
1995-01-01
The radial power distribution in a VVER-440 type fuel assembly is strongly non-uniform as a result of the water-gap between the shrouds and the moderator filled central tube. Consequently, it can be expected that the power density inside a single fuel rod is inhomogeneous, as well. In the paper the methodology and the results of coupled thermohydraulic and neutronic calculations are presented. The objective of the analysis was the investigation of the heat source distribution and the determination of the possible extent of the power non-uniformity in a corner rod which has always the highest peaking factor in a VVER-440 type assembly. The results of the analysis revealed that there can be a strong non-uniformity of power distribution inside a fuel pellet, and the effect depends first of all on the general assembly conditions, while the local subchannel parameters have only a slight influence on the pellet heat source distribution. (author)
A method to measure depth distributions of implanted ions
International Nuclear Information System (INIS)
Arnesen, A.; Noreland, T.
1977-04-01
A new variant of the radiotracer method for depth distribution determinations has been tested. Depth distributions of radioactive implanted ions are determined by dissolving thin, uniform layers of evaporated material from the surface of a backing and by measuring the activity before and after the layer removal. The method has been used to determine depth distributions for 25 keV and 50 keV 57 Co ions in aluminium and gold. (Auth.)
Equivalent (uniform) square field sizes of flattening filter free photon beams
Lechner, Wolfgang; Kuess, Peter; Georg, Dietmar; Palmans, Hugo
2017-10-01
Various types of treatment units, such as CyberKnife, TomoTherapy and C-arm linear accelerators (LINACs) are operated using flattening filter free (FFF) photon beams. Their reference dosimetry, however, is currently based on codes of practice that provide data which were primarily developed and tested for high-energy photon beams with flattening filter (WFF). The aim of this work was to introduce equivalent uniform square field sizes of FFF beams to serve as a basis of a unified reference dosimetry procedure applicable to all aforementioned FFF machines. For this purpose, in-house determined experimental data together with published data of the ratio of doses at depths of 20 cm and 10 cm in water (D 20,10) were used to characterize the depth dose distribution of 6 and 10 MV WFF and FFF beams. These data were analyzed for field sizes ranging from 2 × 2 cm2 to 40 × 40 cm2. A scatter function that takes the lateral profiles of the individual beams into account was fitted to the experimental data. The lateral profiles of the WFF beams were assumed to be uniform, while those of the FFF beams were approximated using fourth or sixth order polynomials. The scatter functions of the FFF beams were recalculated using a uniform lateral profile (the same as the physical profile of the WFF beams), and are henceforth denoted as virtual uniform FFF beams (VUFFF). The field sizes of the VUFFF beams having the same scatter contribution as the corresponding FFF beams at a given field size were defined as the equivalent uniform square field (EQUSF) size. Data from four different LINACs with 18 different beams in total, as well as a CyberKnife beam, were analyzed. The average values of EQUSFs over all investigated LINACs of the conventional 10 × 10 cm2 reference fields of 6 MV and 10 MV FFF beams for C-arm LINACs and machine-specific reference fields for CyberKnife and TomoTherapy were 9.5 cm, 9 cm, 5.0 cm and 6.5 cm respectively. The
Distribution of nutrients in the Periyar river estuary
Digital Repository Service at National Institute of Oceanography (India)
Devi, K.S.; Sankaranarayanan, V.N.; Venugopal, P.
higher values compared to the surface and bottom water. Irregular pattern of distribution of ammonia was recorded at all stations. Early monsoon season showed uniform conditions in this section. Subsequently a build up of nutrients in the mid...
Energy Technology Data Exchange (ETDEWEB)
Periyadurai, K. [Department of Mathematics, Bharathiar University, Coimbatore 641046, Tamil Nadu (India); Muthtamilselvan, M., E-mail: muthtamill@yahoo.co.in [Department of Mathematics, Bharathiar University, Coimbatore 641046, Tamil Nadu (India); Doh, Deog-Hee [Division of Mechanical Engineering, College of Engineering,Korea Maritime Ocean University, Busan 606781 (Korea, Republic of)
2016-12-15
In the present study, the effect of inclined magnetic field on natural convection of micro-polar fluid in a square cavity with uniform and nonuniform heated thin plate built in centrally is investigated numerically. The vertical walls are cooled while the top and bottom walls are insulated. The thin plate is assumed to be isothermal with a linearly varying temperature. The governing equations were solved by finite volume method using second order central difference scheme and upwind differencing scheme. The numerical investigation is carried out for different governing parameters namely, the Hartmann number, inclination angle of magnetic field, Rayleigh number, vortex viscosity and source non-uniformity parameters. The result shows that the heat transfer rate is decreased when increasing Hartmann number, inclination angle of magnetic field and vortex viscosity parameter. It is found that the non-uniformity parameter affects the fluid flow and temperature distribution especially for the high Rayleigh numbers. Finally, the overall heat transfer rate of micro-polar fluids is found to be smaller than that of Newtonian fluid. - Highlights: • We investigate the effect of inclined magnetic field on micropolar fluid in a cavity. • The effects of uniform and non-uniform heated plate are studied. • The present numerical results are compared with the experimental results. • The addition of vortex viscosity parameter declines the heat transfer performance. • The high heat transfer rate occurs in the vertical plate compared to the horizontal one.
Das materialidades da escola: o uniforme escolar On the materialities of school: the school uniform
Directory of Open Access Journals (Sweden)
Ivanir Ribeiro
2012-09-01
Full Text Available Este texto dedica-se a situar o uniforme escolar como objeto histórico e como importante fonte do e no universo escolar. Para tanto, empreende-se uma revisão da literatura que aborda a temática e investe-se em uma reflexão que concebe esse artefato como uma das expressões da materialidade que dá contornos à forma escolar, tomando-o na perspectiva da cultura material. Alguns autores servem aqui de referência: Richard Bucaille, Jean-Marie Pesez e Ulpiano Bezerra de Meneses, nos estudos em que se dedicam à cultura material; Agustín Benito Escolano e Rosa Fátima de Souza, nos trabalhos em que voltam o olhar para cultura material escolar; Inês Dussel e Katiene Nogueira da Silva, autoras que abordam diretamente a questão dos uniformes escolares. Não menos importantes para efeitos deste artigo são os trabalhos que tratam do movimento higienista, particularmente aqueles levados a cabo por José Gondra. Os dados levantados e as reflexões efetuadas indiciam dois movimentos (ou tensões nada desprezíveis. Por um lado, são evidentes as dificuldades encontradas para adoção dos uniformes escolares por todos os alunos, tanto por parte do Estado quanto por parte das famílias, devido ao fato de eles representarem um custo elevado, principalmente os calçados, artigos pouco utilizados pela maioria da população até, no mínimo, meados do século XX. Por outro lado, há indícios de que esse traje desempenhava uma função niveladora importante. Por meio dele, criava-se uma ideia de padronização e democratização do ensino, mesmo que em aparência, além de se dar visibilidade pública a uma instituição social cada vez mais importante: a escola.This text is devoted to situate the school uniform as a historical object, and as an important source on and in the school universe. For that, a literature survey is carried out on this theme, and a reflection is conducted envisaging this artifact as one of the expressions of materiality that
Non-uniform Solar Temperature Field on Large Aperture, Fully-Steerable Telescope Structure
Liu, Yan
2016-09-01
In this study, a 110-m fully steerable radio telescope was used as an analysis platform and the integral parametric finite element model of the antenna structure was built in the ANSYS thermal analysis module. The boundary conditions of periodic air temperature, solar radiation, long-wave radiation shadows of the surrounding environment, etc. were computed at 30 min intervals under a cloudless sky on a summer day, i.e., worstcase climate conditions. The transient structural temperatures were then analyzed under a period of several days of sunshine with a rational initial structural temperature distribution until the whole set of structural temperatures converged to the results obtained the day before. The non-uniform temperature field distribution of the entire structure and the main reflector surface RMS were acquired according to changes in pitch and azimuth angle over the observation period. Variations in the solar cooker effect over time and spatial distributions in the secondary reflector were observed to elucidate the mechanism of the effect. The results presented here not only provide valuable realtime data for the design, construction, sensor arrangement and thermal deformation control of actuators but also provide a troubleshooting reference for existing actuators.
Directory of Open Access Journals (Sweden)
Gabrielle A. Jacquet
2013-01-01
Full Text Available Background. There are currently 34 International Emergency Medicine (IEM fellowship programs. Applicants and programs are increasing in number and diversity. Without a standardized application, applicants have a difficulty approaching programs in an informed and an organized method; a streamlined application system is necessary. Objectives. To measure fellows’ knowledge of their programs’ curricula prior to starting fellowship and to determine what percent of fellows and program directors would support a universal application system. Methods. A focus group of program directors, recent, and current fellows convened to determine the most important features of an IEM fellowship application process. A survey was administered electronically to a convenience sample of 78 participants from 34 programs. Respondents included fellowship directors, fellows, and recent graduates. Results. Most fellows (70% did not know their program’s curriculum prior to starting fellowship. The majority of program directors and fellows support a uniform application service (81% and 67%, resp. and deadline (85% for both. A minority of program directors (35% and fellows (30% support a formal match. Conclusions. Program directors and fellows support a uniform application service and deadline, but not a formalized match. Forums for disseminating IEM fellowship information and for administering a uniform application service and deadline are currently in development to improve the process.
Spatial oxygen distribution and nitrous oxide emissions from soil after manure application
DEFF Research Database (Denmark)
Zhu, Kun; Bruun, Sander; Larsen, Morten
2014-01-01
The availability and spatial distribution of oxygen (O2) in agricultural soil are controlling factors in the production and emission of nitrous oxide (N2O) to the atmosphere, but most experiments investigating the effects of various factors on N2O emissions in soil have been conducted without...... to interpret data on N2O emissions following a uniform or layered amendment of manure to agricultural soil. The spatial distribution of O2 and gas emission rates were monitored for 12 h. An anoxic layer formed rapidly around the layered manure, whereas the uniformly distributed manure led to a more widespread...... anoxia. Nitrous oxide emissions increased immediately after depletion of O2 in the manure-amended treatments. Greater understanding and improved knowledge of the spatial distribution of O2 is clearly beneficial and can be used to devise improved application strategies for mitigating N2O emissions from...
Washing and changing uniforms: is guidance being adhered to?
Potter, Yvonne Camilla; Justham, David
To allay public apprehension regarding the risk of nurses' uniforms transmitting healthcare-associated infections (HCAI), national and local guidelines have been issued to control use, laundry and storage. This paper aims to measure the knowledge of registered nurses (RNs) and healthcare assistants (HCAs) working within a rural NHS foundation Trust and their adherence to the local infection prevention and control (IPC) standard regarding uniforms through a Trust-wide audit. Stratified random sampling selected 597 nursing staff and 399 responded (67%) by completing a short questionnaire based on the local standard. Responses were coded and transferred to SPSS (v. 17) for analysis. The audit found that nursing staff generally adhere to the guidelines, changing their uniforms daily and immediately upon accidental soiling, and wearing plastic aprons where indicated. At home, staff normally machine-wash and then iron their uniforms at the hottest setting. Nevertheless, few observe the local direction to place their newly-laundered uniforms in protective covers. This paper recommends a re-audit to compare compliance rates with baseline figures and further research into the reasons why compliance is lacking to sanction interventions for improvement, such as providing relevant staff education and re-introducing appropriate changing facilities.
Leader propagation in uniform background fields in SF6
International Nuclear Information System (INIS)
Seeger, M; Niemeyer, L; Bujotzek, M
2009-01-01
The breakdown mechanism of compressed SF 6 in gas insulation is known to be controlled by stepped leader propagation. This process is still not well understood in uniform and weakly non-uniform background fields with small electrode protrusions, such as particles or surface roughness. In a previous publication an investigation of partial discharges and breakdown in uniform background fields that focused on streamer and leader inception mechanisms was presented (Seeger et al 2008 J. Phys. D: Appl. Phys. 41 185204). In this paper we present for the first time a physical leader propagation model that consistently describes the observed phenomena in uniform background fields in SF 6 . The model explains two different types of leader breakdown; these can be associated with the precursor and the stem mechanisms. It also yields the parameters of stepped leader propagation, which include step lengths, associated step charges, step times and fields and temperatures in the leader channel. Further, it explains the features of arrested leaders in uniform background fields. The model predicts the range of parameters under which arrested and breakdown leaders occur in good agreement with the experimental data.
HIROSE,Hideo
1998-01-01
TYPES OF THE DISTRIBUTION:13;Normal distribution (2-parameter)13;Uniform distribution (2-parameter)13;Exponential distribution ( 2-parameter)13;Weibull distribution (2-parameter)13;Gumbel Distribution (2-parameter)13;Weibull/Frechet Distribution (3-parameter)13;Generalized extreme-value distribution (3-parameter)13;Gamma distribution (3-parameter)13;Extended Gamma distribution (3-parameter)13;Log-normal distribution (3-parameter)13;Extended Log-normal distribution (3-parameter)13;Generalized ...
Weak value distributions for spin 1/2
Berry, M. V.; Dennis, M. R.; McRoberts, B.; Shukla, P.
2011-05-01
The simplest weak measurement is of a component of spin 1/2. For this observable, the probability distributions of the real and imaginary parts of the weak value, and their joint probability distribution, are calculated exactly for pre- and postselected states uniformly distributed over the surface of the Poincaré-Bloch sphere. The superweak probability, that the real part of the weak value lies outside the spectral range, is 1/3. This case, with just two eigenvalues, complements our previous calculation (Berry and Shukla 2010 J. Phys. A: Math. Theor. 43 354024) of the universal form of the weak value probability distribution for an operator with many eigenvalues.
Weak value distributions for spin 1/2
International Nuclear Information System (INIS)
Berry, M V; Dennis, M R; McRoberts, B; Shukla, P
2011-01-01
The simplest weak measurement is of a component of spin 1/2. For this observable, the probability distributions of the real and imaginary parts of the weak value, and their joint probability distribution, are calculated exactly for pre- and postselected states uniformly distributed over the surface of the Poincare-Bloch sphere. The superweak probability, that the real part of the weak value lies outside the spectral range, is 1/3. This case, with just two eigenvalues, complements our previous calculation (Berry and Shukla 2010 J. Phys. A: Math. Theor. 43 354024) of the universal form of the weak value probability distribution for an operator with many eigenvalues.
International Nuclear Information System (INIS)
Badirkhan, Z.; Pastore, G.; Tosi, M.P.
1991-06-01
Calculations of the thermodynamic properties and pair distribution function of a one-component classical fluid of charged hard spheres in a uniform neutralizing background are reported and compared with Monte Carlo results of Hansen and Weis. Thermodynamic selfconsistence between the virial pressure and the fluctuations formula for the isothermal compressibility is enforced in the calculations by various alternative approaches. The role of thermodynamic selfconsistence is crucial to obtain a satisfactory quantitative description of this model fluid, in view of its applications in the theory of liquid metals and of dispersions of charged colloidal particles. (author). 23 refs, 4 figs, 3 tabs
Detka, Małgorzata
2017-08-01
The paper presents results of numerical analyses of the response of a uniform fiber Bragg grating subjected to a strain with non-smooth profile. Results of measurements of the response of the grating to a compressive strain correspond well with results of the simulation and show, that the induced strain profile of the grating causes a widening of its reflection spectrum with a considerable shape irregularity, dependent on the location of the point where slope of the strain profile changes abruptly, and on the maximum value of the strain.
Dynamically assisted Schwinger effect beyond the spatially-uniform-field approximation
Aleksandrov, I. A.; Plunien, G.; Shabaev, V. M.
2018-06-01
We investigate the phenomenon of electron-positron pair production from vacuum in the presence of a strong electric field superimposed by a weak but fast varying pulse which substantially increases the total particle yield. We employ a nonperturbative numerical technique and perform the calculations beyond the spatially-uniform-field approximation, i.e., dipole approximation, taking into account the coordinate dependence of the fast component. The analysis of the main characteristics of the pair-production process (momentum spectra of particles and total amount of pairs) reveals a number of important features which are absent within the previously used approximation. In particular, the structure of the momentum distribution is modified both qualitatively and quantitatively, and the total number of pairs created as well as the enhancement factor due to dynamical assistance become significantly smaller.
Energy Technology Data Exchange (ETDEWEB)
Qiu, J; Zheng, X; Liu, H; Chen, B; Zhuo, W [FuDan University HuaDong Hospital, Institute of Radiation Medicine Fudan University Shanghai, Shanghai (China)
2016-06-15
Purpose: This study is to evaluate the feasibility of simultaneously integrated boost (SIB) to hypoxic subvolume (HTV) in nasopharyngeal carcinomas under the guidance of 18F-Fluoromisonidazole (FMISO) PET/CT using a novel non-uniform volumetric modulated arc therapy (VMAT)technique. Methods: Eight nasopharyngeal carcinoma patients treated with conventional uniform VMAT were retrospectively analyzed. For each treatment, actual conventional uniform VMAT plan with two or more arcs (2–2.5 arcs, totally rotating angle < 1000o) was designed with dose boost to hopxic subvolume (total dose, 84Gy) in the gross tumor volme (GTV) under the guidance of 18F- FMISO PET/CT. Based on the same dataset, experimental single arc non-uniform VAMT plans were generated with the same dose prescription using customized software tools. Dosimetric parameters, quality assurance and the efficiency of the treatment delivery were compared between the uniform and non-uniform VMAT plans. Results: To develop the non-uniform VMAT technique, a specific optimization model was successfully established. Both techniques generate high-quality plans with pass rate (>98%) with the 3mm, 3% criterion. HTV received dose of 84.1±0.75Gy and 84.1±1.2Gy from uniform and non-uniform VMAT plans, respectively. In terms of target coverage and dose homogeneity, there was no significant statistical difference between actual and experimental plans for each case. However, for critical organs at risk (OAR), including the parotids, oral cavity and larynx, dosimetric difference was significant with better dose sparing form experimental plans. Regarding plan implementation efficiency, the average machine time was 3.5 minutes for the actual VMAT plans and 3.7 minutes for the experimental nonuniform VMAT plans (p>0.050). Conclusion: Compared to conventional VMAT technique, the proposed non-uniform VMAT technique has the potential to produce efficient and safe treatment plans, especially in cases with complicated anatomical
Constantinides, E. D.; Marhefka, R. J.
1994-01-01
A uniform geometrical optics (UGO) and an extended uniform geometrical theory of diffraction (EUTD) are developed for evaluating high frequency electromagnetic (EM) fields within transition regions associated with a two and three dimensional smooth caustic of reflected rays and a composite shadow boundary formed by the caustic termination or the confluence of the caustic with the reflection shadow boundary (RSB). The UGO is a uniform version of the classic geometrical optics (GO). It retains the simple ray optical expressions of classic GO and employs a new set of uniform reflection coefficients. The UGO also includes a uniform version of the complex GO ray field that exists on the dark side of the smooth caustic. The EUTD is an extension of the classic uniform geometrical theory of diffraction (UTD) and accounts for the non-ray optical behavior of the UGO reflected field near caustics by using a two-variable transition function in the expressions for the edge diffraction coefficients. It also uniformly recovers the classic UTD behavior of the edge diffracted field outside the composite shadow boundary transition region. The approach employed for constructing the UGO/EUTD solution is based on a spatial domain physical optics (PO) radiation integral representation for the fields which is then reduced using uniform asymptotic procedures. The UGO/EUTD analysis is also employed to investigate the far-zone RCS problem of plane wave scattering from two and three dimensional polynomial defined surfaces, and uniform reflection, zero-curvature, and edge diffraction coefficients are derived. Numerical results for the scattering and diffraction from cubic and fourth order polynomial strips are also shown and the UGO/EUTD solution is validated by comparison to an independent moment method (MM) solution. The UGO/EUTD solution is also compared with the classic GO/UTD solution. The failure of the classic techniques near caustics and composite shadow boundaries is clearly
Wada, D.; Murayama, H.
2014-01-01
When Fiber Bragg gratings (FBGs) are used as strain sensors, both longitudinal and lateral strain can be applied uniformly or non-uniformly over the length of the FBGs. In order for the demodulation of such FBG signal, this paper investigates the response of birefringent FBGs which are monitored by distributed measurement system based on optical frequency domain reflectometry. A numerical model of the distributed measurement system is built based on piece-wise uniform approach, which considers polarization states of propagating lights. The numerical model simulates analytical response of birefringent FBGs especially when birefringence induces power fluctuations in the distributed spectra, which can be noise or new opportunity for sensitive monitoring of birefringence. Simulation results show the relationships between the power fluctuations and the polarization states of the propagating lights. Consequently, appropriate methods of polarization control for sensitive distributed birefringent FBG monitoring are discussed.
Optimization of equivalent uniform dose using the L-curve criterion
International Nuclear Information System (INIS)
Chvetsov, Alexei V; Dempsey, James F; Palta, Jatinder R
2007-01-01
Optimization of equivalent uniform dose (EUD) in inverse planning for intensity-modulated radiation therapy (IMRT) prevents variation in radiobiological effect between different radiotherapy treatment plans, which is due to variation in the pattern of dose nonuniformity. For instance, the survival fraction of clonogens would be consistent with the prescription when the optimized EUD is equal to the prescribed EUD. One of the problems in the practical implementation of this approach is that the spatial dose distribution in EUD-based inverse planning would be underdetermined because an unlimited number of nonuniform dose distributions can be computed for a prescribed value of EUD. Together with ill-posedness of the underlying integral equation, this may significantly increase the dose nonuniformity. To optimize EUD and keep dose nonuniformity within reasonable limits, we implemented into an EUD-based objective function an additional criterion which ensures the smoothness of beam intensity functions. This approach is similar to the variational regularization technique which was previously studied for the dose-based least-squares optimization. We show that the variational regularization together with the L-curve criterion for the regularization parameter can significantly reduce dose nonuniformity in EUD-based inverse planning
Optimization of equivalent uniform dose using the L-curve criterion
Energy Technology Data Exchange (ETDEWEB)
Chvetsov, Alexei V; Dempsey, James F; Palta, Jatinder R [Department of Radiation Oncology, University of Florida, Gainesville, FL 32610-0385 (United States)
2007-09-21
Optimization of equivalent uniform dose (EUD) in inverse planning for intensity-modulated radiation therapy (IMRT) prevents variation in radiobiological effect between different radiotherapy treatment plans, which is due to variation in the pattern of dose nonuniformity. For instance, the survival fraction of clonogens would be consistent with the prescription when the optimized EUD is equal to the prescribed EUD. One of the problems in the practical implementation of this approach is that the spatial dose distribution in EUD-based inverse planning would be underdetermined because an unlimited number of nonuniform dose distributions can be computed for a prescribed value of EUD. Together with ill-posedness of the underlying integral equation, this may significantly increase the dose nonuniformity. To optimize EUD and keep dose nonuniformity within reasonable limits, we implemented into an EUD-based objective function an additional criterion which ensures the smoothness of beam intensity functions. This approach is similar to the variational regularization technique which was previously studied for the dose-based least-squares optimization. We show that the variational regularization together with the L-curve criterion for the regularization parameter can significantly reduce dose nonuniformity in EUD-based inverse planning.
Optimization of equivalent uniform dose using the L-curve criterion.
Chvetsov, Alexei V; Dempsey, James F; Palta, Jatinder R
2007-10-07
Optimization of equivalent uniform dose (EUD) in inverse planning for intensity-modulated radiation therapy (IMRT) prevents variation in radiobiological effect between different radiotherapy treatment plans, which is due to variation in the pattern of dose nonuniformity. For instance, the survival fraction of clonogens would be consistent with the prescription when the optimized EUD is equal to the prescribed EUD. One of the problems in the practical implementation of this approach is that the spatial dose distribution in EUD-based inverse planning would be underdetermined because an unlimited number of nonuniform dose distributions can be computed for a prescribed value of EUD. Together with ill-posedness of the underlying integral equation, this may significantly increase the dose nonuniformity. To optimize EUD and keep dose nonuniformity within reasonable limits, we implemented into an EUD-based objective function an additional criterion which ensures the smoothness of beam intensity functions. This approach is similar to the variational regularization technique which was previously studied for the dose-based least-squares optimization. We show that the variational regularization together with the L-curve criterion for the regularization parameter can significantly reduce dose nonuniformity in EUD-based inverse planning.
International Nuclear Information System (INIS)
Quan Ji; Wang Xianjia
2013-01-01
Traditional evolutionary games assume uniform interaction rate, which means that the rate at which individuals meet and interact is independent of their strategies. But in some systems, especially biological systems, the players interact with each other discriminately. Taylor and Nowak (2006) were the first to establish the corresponding non-uniform interaction rate model by allowing the interaction rates to depend on strategies. Their model is based on replicator dynamics which assumes an infinite size population. But in reality, the number of individuals in the population is always finite, and there will be some random interference in the individuals' strategy selection process. Therefore, it is more practical to establish the corresponding stochastic evolutionary model in finite populations. In fact, the analysis of evolutionary games in a finite size population is more difficult. Just as Taylor and Nowak said in the outlook section of their paper, ''The analysis of non-uniform interaction rates should be extended to stochastic game dynamics of finite populations''. In this paper, we are exactly doing this work. We extend Taylor and Nowak's model from infinite to finite case, especially focusing on the infiuence of non-uniform connection characteristics on the evolutionary stable state of the system. We model the strategy evolutionary process of the population by a continuous ergodic Markov process. Based on the limit distribution of the process, we can give the evolutionary stable state of the system. We make a complete classification of the symmetric 2 × 2 games. For each case game, the corresponding limit distribution of the Markov-based process is given when noise intensity is small enough. In contrast with most literatures in evolutionary games using the simulation method, all our results obtained are analytical. Especially, in the dominant-case game, coexistence of the two strategies may become evolutionary stable states in our model. This result can be
Donovan, J.; Jordan, T. H.
2012-12-01
Forecasting the rupture directivity of large earthquakes is an important problem in probabilistic seismic hazard analysis (PSHA), because directivity is known to strongly influence ground motions. We describe how rupture directivity can be forecast in terms of the "conditional hypocenter distribution" or CHD, defined to be the probability distribution of a hypocenter given the spatial distribution of moment release (fault slip). The simplest CHD is a uniform distribution, in which the hypocenter probability density equals the moment-release probability density. For rupture models in which the rupture velocity and rise time depend only on the local slip, the CHD completely specifies the distribution of the directivity parameter D, defined in terms of the degree-two polynomial moments of the source space-time function. This parameter, which is zero for a bilateral rupture and unity for a unilateral rupture, can be estimated from finite-source models or by the direct inversion of seismograms (McGuire et al., 2002). We compile D-values from published studies of 65 large earthquakes and show that these data are statistically inconsistent with the uniform CHD advocated by McGuire et al. (2002). Instead, the data indicate a "centroid biased" CHD, in which the expected distance between the hypocenter and the hypocentroid is less than that of a uniform CHD. In other words, the observed directivities appear to be closer to bilateral than predicted by this simple model. We discuss the implications of these results for rupture dynamics and fault-zone heterogeneities. We also explore their PSHA implications by modifying the CyberShake simulation-based hazard model for the Los Angeles region, which assumed a uniform CHD (Graves et al., 2011).
Beam energy distribution influences on density modulation efficiency in seeded free-electron lasers
Directory of Open Access Journals (Sweden)
Guanglei Wang
2015-06-01
Full Text Available The beam energy spread at the entrance of an undulator system is of paramount importance for efficient density modulation in high-gain seeded free-electron lasers (FELs. In this paper, the dependences of high harmonic bunching efficiency in high-gain harmonic generation (HGHG, echo-enabled harmonic generation (EEHG and phase-merging enhanced harmonic generation (PEHG schemes on the electron beam energy spread distribution are studied. Theoretical investigations and multidimensional numerical simulations are applied to the cases of uniform and saddle beam energy distributions and compared to a traditional Gaussian distribution. It shows that the uniform and saddle electron energy distributions significantly enhance the bunching performance of HGHG FELs, while they almost have no influence on EEHG and PEHG schemes. A further start-to-end simulation example demonstrated that, with the saddle distribution of sliced beam energy spread controlled by a laser heater, the 30th harmonic can be directly generated by a single-stage HGHG scheme for a soft x-ray FEL facility.
Giovannini, Massimo
2015-01-01
Cosmological singularities are often discussed by means of a gradient expansion that can also describe, during a quasi-de Sitter phase, the progressive suppression of curvature inhomogeneities. While the inflationary event horizon is being formed the two mentioned regimes coexist and a uniform expansion can be conceived and applied to the evolution of spatial gradients across the protoinflationary boundary. It is argued that conventional arguments addressing the preinflationary initial conditions are necessary but generally not sufficient to guarantee a homogeneous onset of the conventional inflationary stage.
X-ray radiographic technique for measuring density uniformity of silica aerogel
International Nuclear Information System (INIS)
Tabata, Makoto; Hatakeyama, Yoshikiyo; Adachi, Ichiro; Morita, Takeshi; Nishikawa, Keiko
2013-01-01
This paper proposes a new X-ray radiographic technique for measuring density uniformity of silica aerogels used as radiator in proximity-focusing ring-imaging Cherenkov detectors. To obtain high performance in a large-area detector, a key characteristic of radiator is the density (i.e. refractive index) uniformity of an individual aerogel monolith. At a refractive index of n=1.05, our requirement for the refractive index uniformity in the transverse plane direction of an aerogel tile is |δ(n−1)/(n−1)|<4% in a focusing dual layer radiator (with different refractive indices) scheme. We applied the radiographic technique to evaluate the density uniformity of our original aerogels from a trial production and that of Panasonic products (SP-50) as a reference, and to confirm they have sufficient density uniformity within ±1% along the transverse plane direction. The measurement results show that the proposed technique can quantitatively estimate the density uniformity of aerogels.
Huang, Zhi; Marra, Francesco; Subbiah, Jeyamkondan; Wang, Shaojin
2018-04-13
Radio frequency (RF) heating has great potential for achieving rapid and volumetric heating in foods, providing safe and high-quality food products due to deep penetration depth, moisture self-balance effects, and leaving no chemical residues. However, the nonuniform heating problem (usually resulting in hot and cold spots in the heated product) needs to be resolved. The inhomogeneous temperature distribution not only affects the quality of the food but also raises the issue of food safety when the microorganisms or insects may not be controlled in the cold spots. The mathematical modeling for RF heating processes has been extensively studied in a wide variety of agricultural products recently. This paper presents a comprehensive review of recent progresses in computer simulation for RF heating uniformity improvement and the offered solutions to reduce the heating nonuniformity. It provides a brief introduction on the basic principle of RF heating technology, analyzes the applications of numerical simulation, and discusses the factors influencing the RF heating uniformity and the possible methods to improve heating uniformity. Mathematical modeling improves the understanding of RF heating of food and is essential to optimize the RF treatment protocol for pasteurization and disinfestation applications. Recommendations for future research have been proposed to further improve the accuracy of numerical models, by covering both heat and mass transfers in the model, validating these models with sample movement and mixing, and identifying the important model parameters by sensitivity analysis.
The European Food Consumption Validation Project: conclusions and recommendations
DEFF Research Database (Denmark)
de Boer, E. J.; Slimani, N.; van 't Veer, P.
2011-01-01
Background/Objectives: To outline and discuss the main results and conclusions of the European Food Consumption Validation (EFCOVAL) Project. Subjects/Methods: The EFCOVAL Project was carried out within the EU Sixth Framework Program by researchers in 11 EU countries. The activities focused on (1...... showed that two non-consecutive EPIC-Soft 24-HDRs are suitable to estimate the usual intake distributions of protein and potassium of European adult populations. The 2-day non-consecutive 24-HDRs in combination with a food propensity questionnaire also appeared to be appropriate to rank individuals...... according to their fish and fruit and vegetable intake in a comparable way in five European centers. Dietary intake of (young) children can be assessed by the combination of EPIC-Soft 24-HDRs and food recording booklets. The EPIC-Soft-standardized method of describing foods is useful to estimate dietary...
Liu, Chong; Dobrynin, Danil; Fridman, Alexander
2014-06-25
In this study, we report experimental results on fast ICCD imaging of development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of electric field in the discharge. Uniformity of the discharge images obtained with nanosecond exposure times were analyzed using chi-square test. The results indicate that DBD uniformity strongly depends on applied (global) electric field in the discharge gap, and is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is transition from filamentary to uniform DBD mode which correlates to the corresponding decrease of maximum local electric field in the discharge.
Device for flattening statistically distributed pulses
International Nuclear Information System (INIS)
Il'kanaev, G.I.; Iskenderov, V.G.; Rudnev, O.V.; Teller, V.S.
1976-01-01
The description is given of a device that converts the series of statistically distributed pulses into a pseudo-uniform one. The inlet pulses switch over the first counter, and the second one is switched over by the clock pulses each time the uniformity of the counters' states is violated. This violation is recorded by the logic circuit which passes to the output the clock pulses in the amount equal to that of the pulses that reached the device inlet. Losses at the correlation between the light velocity and the sampling rate up to 0.3 do not exceed 0.7 per cent for the memory of pulse counters 3, and 0.035 per cent for memory 7
Theoretical method for determining particle distribution functions of classical systems
International Nuclear Information System (INIS)
Johnson, E.
1980-01-01
An equation which involves the triplet distribution function and the three-particle direct correlation function is obtained. This equation was derived using an analogue of the Ornstein--Zernike equation. The new equation is used to develop a variational method for obtaining the triplet distribution function of uniform one-component atomic fluids from the pair distribution function. The variational method may be used with the first and second equations in the YBG hierarchy to obtain pair and triplet distribution functions. It should be easy to generalize the results to the n-particle distribution function
2013-08-19
... Organization (HMO) Benefit--Prime Enrollment Fee Exemption for Survivors of Active Duty Deceased Sponsors and... Enrollment Fee Exemption for Survivors of Active Duty Deceased Sponsors and Medically Retired Uniformed Services [[Page 50360
International Nuclear Information System (INIS)
Pastor, G.; Dominguez, C.; Lora-Tamayo, E.; Dominguez, E.
1987-01-01
The present work is a study about the uniformity of the silicon deposition in the LPCVD system starting out from the pure silane. It is concluded that it is necessary to take account of all the parameters involved (pressure, temperature, gas flow, number, position and spacing between wafers). From the point of view of the uniformity, three kinds of depositions are observed: poly uniform zone, poly non-uniform zone and amorphous precipitates zone. In the non-uniform zone the increase of the non-uniformity obeys an exponential low when only one of the parameters of the system changes. However, in the amorphous precipitates zone the non-uniformity tends to a constant value. By drawing the values of pressure (P) and gas flow (C), for a fixed temperature, that separates both the uniform/non-uniform and amorphous/policrystalline zones, the equation P n C m #alpha # K(T) are fulfilled where K is a function of temperature. 10 refs
Energy Technology Data Exchange (ETDEWEB)
Wang, Haiqiang; Wang, Penglu [Key Laboratory of Environment Remediation and Ecological Health, Ministry of Education, College of Environmental & Resources Science, Zhejiang University, 310058 Hangzhou (China); Zhejiang Provincial Engineering Research Center of Industrial Boiler & Furnace Flue Gas Pollution Control, Hangzhou 310027 (China); Chen, Xiongbo [South China Institute of Environmental Sciences, Ministry of Environmental Protection, Guangzhou 510655 (China); Wu, Zhongbiao, E-mail: zbwu@zju.edu.cn [Key Laboratory of Environment Remediation and Ecological Health, Ministry of Education, College of Environmental & Resources Science, Zhejiang University, 310058 Hangzhou (China); Zhejiang Provincial Engineering Research Center of Industrial Boiler & Furnace Flue Gas Pollution Control, Hangzhou 310027 (China)
2017-02-15
Highlights: • VOSO{sub 4} exhibited better synergistic effect with titanate nanotubes than NH{sub 4}VO{sub 3}. • Ion-exchange reaction occurs between VOSO{sub 4} and titanate nanotubes. • Ion-exchange resulting in uniformly vanadium distribution on titanate nanotubes. • VOSO{sub 4}-based catalyst exhibited impressive SCR activity and alkaline resistance. - Abstract: In this work, protonated titanate nanotubes was performed as a potential useful support and different vanadium precursors (NH{sub 4}VO{sub 3} and VOSO{sub 4}) were used to synthesize deNO{sub x} catalysts. The results showed that VOSO{sub 4} exhibited better synergistic effect with titanate nanotubes than NH{sub 4}VO{sub 3}, which was caused by the ion-exchange reaction. Then high loading content of vanadium, uniformly active phase distribution, better dispersion of vanadium, more acid sites, better V{sup 5+}/V{sup 4+} redox cycles and superior oxygen mobility were achieved. Besides, VOSO{sub 4}-based titanate nanotubes catalysts also showed enhanced alkaline resistance than particles (P25) based catalysts. It was strongly associated with its abundant acid sites, large surface area, flexible redox cycles and oxygen transfer ability. For the loading on protonated titanate nanotubes, active metal with cation groups was better precursors than anion ones. V{sub 2}O{sub 5}/TNTs catalyst was a promising substitute for the commercial vanadium catalysts and the work conducted herein provided a useful idea to design uniformly active phase loaded catalyst.
Strange distributionally chaotic triangular maps II
International Nuclear Information System (INIS)
Paganoni, L.; Smital, J.
2006-01-01
The notion of distributional chaos was introduced by Schweizer and Smital [Measures of chaos and a spectral decomposition of dynamical systems on the interval, Trans Am Math Soc 1994;344:737-854] for continuous maps of the interval. For continuous maps of a compact metric space three mutually non-equivalent versions of distributional chaos, DC1-DC3, can be considered. In this paper we study distributional chaos in the class T m of triangular maps of the square which are monotone on the fibres. The main results: (i) If F-bar T m has positive topological entropy then F is DC1, and hence, DC2 and DC3. This result is interesting since similar statement is not true for general triangular maps of the square [Smital and Stefankova, Distributional chaos for triangular maps, Chaos, Solitons and Fractals 2004;21:1125-8]. (ii) There are F 1 ,F 2 -bar T m which are not DC3, and such that not every recurrent point of F 1 is uniformly recurrent, while F 2 is Li and Yorke chaotic on the set of uniformly recurrent points. This, along with recent results by Forti et al. [Dynamics of homeomorphisms on minimal sets generated by triangular mappings, Bull Austral Math Soc 1999;59:1-20], among others, make possible to compile complete list of the implications between dynamical properties of maps in T m , solving a long-standing open problem by Sharkovsky
Single-server queues with spatially distributed arrivals
Kroese, Dirk; Schmidt, Volker
1994-01-01
Consider a queueing system where customers arrive at a circle according to a homogeneous Poisson process. After choosing their positions on the circle, according to a uniform distribution, they wait for a single server who travels on the circle. The server's movement is modelled by a Brownian motion
Spatial distribution sampling and Monte Carlo simulation of radioactive isotopes
Krainer, Alexander Michael
2015-01-01
This work focuses on the implementation of a program for random sampling of uniformly spatially distributed isotopes for Monte Carlo particle simulations and in specific FLUKA. With FLUKA it is possible to calculate the radio nuclide production in high energy fields. The decay of these nuclide, and therefore the resulting radiation field, however can only be simulated in the same geometry. This works gives the tool to simulate the decay of the produced nuclide in other geometries. With that the radiation field from an irradiated object can be simulated in arbitrary environments. The sampling of isotope mixtures was tested by simulating a 50/50 mixture of $Cs^{137}$ and $Co^{60}$. These isotopes are both well known and provide therefore a first reliable benchmark in that respect. The sampling of uniformly distributed coordinates was tested using the histogram test for various spatial distributions. The advantages and disadvantages of the program compared to standard methods are demonstrated in the real life ca...
Digital Repository Service at National Institute of Oceanography (India)
Yamazaki, T.; Sharma, R.
that many locations have high crust coverages with highly undulating microtopography. High nodule coverages occur on relatively flat seafloor, and the nodule size distribution varies from uniform to inhomogeneous among different locations. Distribution...
Buttoned down: Are School Uniform Policies a Perfect Fit for All Students?
Messitt, Maggie
2013-01-01
In the 1999-2000 school year, only about 12 percent of U.S. public schools required their students to wear uniforms. Since then, the number of schools requiring uniforms has risen. Uniform policies are now in place at about a fifth of all public schools in the United States--but do school uniforms really level the playing field? New research has…