WorldWideScience

Sample records for concentracion del radon

  1. Daily fluctuations in radon concentration in a Cordoba factory complex; Fluctuaciones diurnas de la concentracion de {sup 222}Rn en el complejo fabril Cordoba

    Energy Technology Data Exchange (ETDEWEB)

    Germanier, A; Perez, R; Rubio, M [CEPROCOR, Cordoba (Argentina)

    1998-07-01

    Full text: This work shows the fluctuations of indoor radon concentration in some rooms placed inside a Cordoba Factory Complex. The measurements were performed by Victoreen Radon Monitor. The system was shaped to sample single radon concentration values after one hour integration. It utilizes a passive diffusion chamber and a silicon diffused junction detector. A portion of decay products will plate-out onto the detector and emit alpha particles into the depletion region of a diffused junction detector. The alpha energy is deposited in the detector in the form of ionization which generates a charge pulse. Only alpha pulses of an energy level similar Po-218 and Po-214 are detected. The study of the meteorological parameters shows that the daily fluctuations of the radon concentration respond to the transport and dispersion processes of radon gas through the air. Air temperature, wind's direction and speed are found to be fundamentals parameters in the observed time behavior. The meteorological data were obtained by a portable station (Davis Weathe Monitor II). The radon concentration present a maximum value (1850 Bq/m{sup 3}) at the night and a minimum value (150 Bq/m{sup 3}) at the day. (author)S. [Spanish] Texto completo: En este trabajo se estudian las fluctuaciones de la concentracion de radon 222 en aire 'indoor' en distintas habitaciones ubicadas dentro y fuera del predio del Complejo Fabril Cordoba (C.F.C.). Las determinaciones se realizaron con un detector pasivo Radon Monitor 05-418, marca Victoreen. El mismo consta de una camara de difusion electrostatica y de un detector de estado solido (Si) de juntura difundida. Este instrumento se configuro para obtener integraciones para cada una de las horas del dia. El principio de funcionamiento del detector se basa en el conteo de los decaimientos {alpha} del polonio 218 y polonio 214 atrapados dentro de la camara de difusion electrostatica. El build-up ocurrido dentro de esta camara es tenido en cuenta para

  2. Concentraciones de activador tisular del plasminógeno e inhibidor del activador del plasminógeno en pacientes con homocistinuria clásica

    Directory of Open Access Journals (Sweden)

    SA Castañeda

    2001-07-01

    Full Text Available El objetivo de este estudio fue determinar las concentraciones de homocisteína (Hcy, inhibidor del activador del plasminógeno tipo 1 (PAI-1 y activador tisular del plasminógeno (tPA en pacientes con homocistinuria clásica, en familiares de éstos y en población control sana.

  3. Radon gas inside historical buildings in the city of Cordoba; Gas {sup 222}Rn en construcciones historicas de la ciudad de Cordoba

    Energy Technology Data Exchange (ETDEWEB)

    Perez, R; Germanier, A; Rubio, M [CEPROCOR, Cordoba (Argentina); Sbarato, D; Zappino, R [Observatorio Ambiental de la Municipalidad de Cordoba, Cordoba (Argentina)

    1998-07-01

    Full text: In this work measurements of the Radon ({sup 222}Rn) concentration in the inside of historical buildings which date back to the end of the 17th and the beginning of the 18th Centuries have been carried out in the city of Cordoba (Argentina). Meteorological factors such as room temperature and atmospheric pressure have not shown to affect, to a great extent, the results obtained. By comparing the concentration of {sup 222}Rn in environments at different levels we inferred that the soil underlying the buildings does not represent an important source of {sup 222}Rn. The main occurrence of the element was found in room walls, which shows that local building materials are an important source of {sup 222}Rn. Among the materials used in these buildings are granitic rocks, and to a lesser extent, lime, sand and marble. The {sup 222}Rn concentrations recorded in some of the rooms surveyed reach values which are close to the minimum intervene level set by international standards in 4pCi/l. The study of the effects of ventilation in the concentration of {sup 222}Rn allows us to conclude that its values decrease to accepted levels by means of a natural and efficient ventilation of the rooms. (author) [Spanish] Texto completo: En este trabajo se han realizado mediciones de la concentracion de radon (radon 222) en el interior de edificios de la ciudad de Cordoba que datan de finales del siglo XVII y comienzos del siglo XVIII. Las concentraciones de radon 222 se determinaron con un detector pasivo Radon Monitor 05-418, marca Victoreen. El mismo consta de una camara de difusion electrostatica y un detector de estado solido (Si) de juntura difundida. No se observo, en los resultados obtenidos, influencias causadas por factores meteorologicos como la temperatura ambiente y la presion atmosferica. Por comparacion de la concentracion de radon 222 en ambientes ubicados en distintas plantas se dedujo que el suelo subyacente bajo los edificios representa una fuente secundaria

  4. Concentraciones del activador tisular del plasminógeno y del inhibidor del activador del plasminógeno en pacientes con homocistinuria clásica

    Directory of Open Access Journals (Sweden)

    Beatriz Meneses

    2001-04-01

    Full Text Available El aumento moderado o severo de Homocisteína (Hcy en sangre y las alteraciones en el sistema fibrinolítico, se asocian con enfermedad vascular que afecta venas y arterias de todos los calibres. Los pacientes con homocistinuria clásica padecen con mucha frecuencia eventos tromboembólicos, que son su principal causa de mortalidad. El objetivo de este estudio fue determinar las concentraciones de Hcy, Inhibidor del Activador del Plasminógeno tipo 1 (PAI-1 y Activador tisular del Plasminógeno (tPA en pacientes con homocistinuria clásica, en familiares de éstos y en población control sana.

  5. A study of radon indoor concentration; Un estudio de concentracion de radon intramuros

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Ruiz, W.; Segovia, N.; Ponciano, G. [ININ, Gerencia de Ciencias Ambientales, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    It was realized a study of radon concentration in houses of Mexico City and in a laboratory of the Nuclear Centre of Salazar, State of Mexico. The radon determination in air was realized with solid nuclear track detectors and with Honeywell and Alpha guard automatic equipment. The results show that the majority of houses have values under 148 Bq/m{sup 3} obtaining some housings with upper values located in the Lomas zone. A study in smokers houses and another of controls showed very similar distributions. It was studied the day time fluctuations finding that radon increases considerably during the dawn. Some upper values obtained in a laboratory of the Nuclear Centre were remedied with ventilation. (Author)

  6. Linear concentration system; Sistema de concentracion lineal

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Lugo, J.I; Leon Rovira, N; Aguayo Tellez, H [Instituto Tecnologico y de Estudios Superiores de Monterrey, Monterrey, Nuevo Leon (Mexico)]. E-mails: a00812662@itesm.mx; noel.leon@itesm.mx; haguayo@itesm.mx

    2013-03-15

    Solar linear concentration technologies to generate high temperatures are limited to the ranges of 200 to 500 degrees Celsius. While its performance has been tested through prototypes and pilot plants around the world, there are still areas of opportunity that can be exploited to obtain a linear concentration that achieves temperatures above this range in order to have a better use of the available solar energy. Because of this: It is possible to develop a linear concentration system that can track the sun with minimal movement of the absorber-receiver while maintaining temperatures above 850 degrees Celsius sufficient for industrial processes that require that temperature. The methodology consists of a series of stages (conceptual design, simulation, evaluation, development concept, results and validation) through which concepts are generated that allow design and evaluation of solar concentrator configurations with the help of simulation software. We have designed a linear parabolic concentrating system which comprises a set of mirrors segments with different focal lengths that works within the range of 600 degrees Celsius; however, it is advancing in the development of a double concentration to reach 850 degrees Celsius. [Spanish] Las tecnologias de concentracion lineal solar para generar altas temperaturas se ven limitadas a los rangos de 200 a 500 grados centigrados. Si bien su funcionamiento ha sido probado a traves de prototipos y plantas piloto alrededor del mundo, aun existen areas de oportunidad que pueden ser aprovechadas para obtener un sistema de concentracion lineal que permita alcanzar temperaturas mayores a este rango para asi tener un mejor aprovechamiento de la energia solar disponible. Debido a esto: Es posible desarrollar un sistema de concentracion lineal capaz de seguir la trayectoria del Sol con minimo movimiento del absorbedor-recibidor al mismo tiempo que mantiene temperaturas superiores a los 850 grados centigrados suficientes para

  7. Geographical information system for radon gas from soil measurement; Il sistema informativo territoriale per la valutazione del potenziale di esalazione di radon dal suolo

    Energy Technology Data Exchange (ETDEWEB)

    Orlando, P.; Amici, M.; Altieri, A.; Massari, P.; Miccadei, E.; Onofri, A.; Orlando, C.; Paolelli, C.; Paron, P.; Perticaroli, P.; Piacentini, T.; Silvestri, C. [Milan Univ. Sacro Cuore, Milan (Italy). Servizio Centralizzato Radioisotopi; Belli, M.; Marchetti, A.; Petrocchi, A.; Rosamilia, S.; Serva, L.; Singh, G.; Tommasino, L. [Agenzia Nazionale per la Protezione dell' Ambiente, Rome (Italy); Minach, L.; Verdi, L. [Agenzia Provinciale per la Protezione dell' Ambiente, Bolzano (Italy); Bertolo, A.; Trotti, F. [Agenzia Regionale per la Protezione dell' Ambiente, Regione Veneto (Italy)

    2000-07-01

    The working program foresees the realization of an geographical information system for the check in field of the geological parameters and determination of uranium and radium contents in various type of rocks. It is here also pointed out a measuring method for radon concentration in soil. [Italian] In questo documento viene presentato il lavoro svolto fino ad oggi: dalla definizione dei parametri geologici ritenuti piu' significativi per la presenza di radon nel suolo e dalle misure in campo e in laboratorio, fino alla realizzazione del Sistema Informativo Territoriale (SIT) per la gestione dei suddetti parametri. Nel primo capitolo sono descritte le caratteristiche del radon, dal punto di vista chimico-fisico e geologico, per introdurre i criteri adottati nella scelta dei paramentri geologici e del loro peso per la valutazione del PERS (Potenziale di Esalazione Radon dal Suolo). Il secondo capitolo descrive il progetto in generale, mentre i successivi capitoli descrivono piu' in dettaglio la parte informatica e quella delle indagini sperimentali.

  8. An Alpha spectrometer for measuring radon daughter individual activity concentration; Spettrometro Alfa per la misura delle concentrazioni individuali in attivita' della progenie del radon

    Energy Technology Data Exchange (ETDEWEB)

    Berico, M.; Formignani, M. [ENEA, Div. Protezione dell' Uomo e degli Ecosistemi, Centro Ricerche E. Clementel, Bologna (Italy); Mariotti, F. [Bologna Univ., Bologna (Italy). Dipt. di Fisica

    2001-07-01

    In the frame of the program of the Institute for Radiation Protection of ENEA, related to the evaluation of dose from radon and thoron progeny, an alpha spectrometer for the continuous air monitoring (CAM type) of radon and thoron has been realized. The constructive characteristics of the device are here presented together with energy and efficiency calibration. The device allows, by means of a screen type diffusion battery and a filter, to determinate the single radioactivity of each radionuclide of the progeny selecting them in relation to their diffusive behaviour (dichotomous particle size selection). The three-count filter method has been employed to measure the concentrations of {sup 218}Po, {sup 214}Pb and {sup 214}Bi in air. Radon and thoron effective doses using a dosimetric, instead of an epidemiologic approach, will be then evaluated. [Italian] Presso l'Istituto per la Radioprotezione, nell'ambito del programma di valutazione di dose da radon e' stato progettato e realizzato uno spettrometro alfa per il monitoraggio continuo in aria (CAM) della progenie del radon e del toron. Le caratteristiche costruttive dello strumento permettono, tramite l'utilizzo di batterie a diffusione a reti, di determinare l'attivita' individuale della progenie per diverse dimensioni granulometriche in particolare per la frazione attaccata e non al particolato amosferico con un taglio granulometrico di qualche nanometro. E' stato inoltre applicato un metodo spettrometrico a tre conteggi per il calcolo delle concentrazioni individuali della progenie del radon, {sup 218}Po, {sup 214}Pb and {sup 214}Bi, effettuando un conteggio alfa di {sup 218}Po e due conteggi alfa di {sup 214}Po. Tale informazione consentira' una valutazione della dose di radon utilizzando il modello dosimetrico in alternativa a quello epidemiologico.

  9. Indoor randon concentration. Temperature and wind effects; Concentrazione di radon indoor. Effetto del vento e della temperatura

    Energy Technology Data Exchange (ETDEWEB)

    Sesana, L.; Benigni, S. [Milan Univ., Milan (Italy). Ist. di Fisica Generale Applicata

    2000-12-01

    The present study analyses and discusses the behaviour of the indoor radon concentration in a research house. Hourly measurements were carried out in the basement of the house from November 1998 up to June 1999. In many sequences of days radon concentration in the room under analysis shows strong variation all day long with accumulation in the evening and overnight and decrease in the morning and in the afternoon. Measurements of wind velocity, indoor and outdoor temperatures and outdoor-indoor pressure difference were performed and their trend is compared with the observed radon concentration. The exhalation of radon from walls, floor and ceiling and the pressure difference driven exhalation from the soil are discussed, particularly the relation with the temperature differences. The air exchange rates between the house and the outdoor air are studied. [Italian] Si analizza e si discute il comportamento della concentrazione di radon indoor nel seminterrato di una casa di ricerca. Misure orarie sono state effettuate da novembre 1998 a giugno 1999. In molte sequenze di giorni la concentrazione del radon nel locale in analisi presenta forti variazioni nel corso della giornata con un accumulo notturno e decrescita nelle ore diurne. Sono state eseguite misure della velocita' del vento, delle temperature outdoor e indoor e della differenza di pressione outdoor-indoor e il loro andamento e' stato confrontato con quello della concentrazione del radon. Vengono discusse l'esalazione del radon dalle pareti, dal pavimento e dal soffitto e l'esalazione pressure difference driven dal suolo. Il rateo dei ricambi d'aria tra il locale e l'aria outdoor e' studiato.

  10. Determination of the radon concentration in soil and ground water and its association with the seismicity; Determinacion de la concentracion del radon en suelo y agua subterranea y su asociacion con la sismicidad

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Segovia, N. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico)

    2003-07-01

    The coast of the Mexican Pacific is one of the seismic areas more active of the world due to the subduction of the badges of Coconuts and Rivera under the badge of North America. The earthquakes that happen in this part of Mexico they are of great magnitude and they affect to the central plateau of the country where finds the biggest population density. On the other hand the coast of the Gulf of Mexico presents one relatively low seismic activity. It is in this region where it is the nuclear plant of Laguna Verde (PNLV) and the studies of seismicity of the area should be carried out for questions of nuclear security. One carries out a study of fluctuations of the concentration of the radon in floor and it dilutes underground in the mentioned areas using accustomed to detectors of nuclear appearances (LR-115). Possibly they were also used detecting automatic (Clipperton sounds out). In some cases it was analysed the gamma radiation in soil using thermoluminescent dosemeters (CaSO{sub 4}: Dy + Ptfe). The mineralogical composition of rock samples was obtained, by means of technical conventional and Electron scanning microscopy and an X-ray diffractometer. The study one carries out along the coast of Guerrero, from Guacamayas, Mich. until Marquelia, Gro., of 1993 at 1998 and in the coast of the Gulf of Mexico, in the PNLV and their surroundings, of 1994 at 1996. The fluctuations of the radon concentration and of the gamma radiation, were analysed in function of the local seismic activity, the meteorological parameters and those characteristic geologic. In the area of the PNLV, the results showed that in general the averages of those value of the radon concentration, as much in floor as in water, they were low. A station located in a flaw area (New Ranch) the one that I present the values was but high of radon concentration, corresponding those but first floor to the PNLV. The seismic activity during the one period of sampling was sporadic and of low intensity and alone

  11. Radon: risk to health? El radón: ¿riesgo para la salud?

    Directory of Open Access Journals (Sweden)

    Juan Miguel Barros Dios

    2011-12-01

    Full Text Available Radon (Rn222 is a radioactive noble gas whose origin is Radium (Ra226 when it emits an alpha particle (two protons and two neutrons or a helium nucleus. Rn222 transforms in another radioactive element (Po218 when an alpha particle is emitted. Its carcinogenic effect on the lung was discovered various decades ago, first on uranium miners and later on general population exposed at home to residential radon. The main factor influencing radon concentration in dwellings is the uranium content of the subsoil, since uranium is the first element of the radioactive disintegration chain where radon appears. Geological risk areas of Spain due to their granite and therefore uranium content are Galicia, the Northwest and the West of Spain. Numerous countries of Europe and America have enforced legislation focused to protect population and reduce radon concentration in order to prevent lung cancer appearance. These laws comprise public buildings and private homes. Since the late 80s, alpha radiation generated by radon and its short-life descendents has been classified as carcinogenic agents by the International Agency for Research on Cancer (Lyon, 1988 and the National Research Council (BEIR IV, 1988.El radón (Rn222 es un gas noble radiactivo que procede directamente del radio (Ra226 cuando este emite una partícula alfa (dos protones y dos neutrones o núcleo de helio, y que a su vez se transforma en otro elemento radiactivo (Po218 al desprenderse de otra partícula alfa. Desde hace varias décadas se conoce su efecto como factor de riesgo del cáncer primario pulmonar, primero en mineros del uranio y posteriormente en la población general expuesta al radón residencial en hogares construidos sobre suelos de rocas ricas en uranio (U238, elemento inicial de la cadena de degradación radiactiva de la que procede el radón. Áreas geológicamente constituidas por granitos o pizarras, como son las de gran parte de Galicia y todo el noroeste y oeste de la pen

  12. Measurements of the radon-222 concentration in residences of Lima - Peru; Mediciones de la concentracion de radon 222 en residencias de Lima - Peru

    Energy Technology Data Exchange (ETDEWEB)

    Pereyra, P.; Lopez, M. E.; Perez, B., E-mail: ppereyr@pucp.edu.pe [Pontificia Universidad Catolica del Peru, Seccion Fisica, Av. Universitaria 1801, Lima (Peru)

    2014-08-15

    The measurement of the Radon-222 levels was realized in the first semester of 2013 in residences corresponding to 16 districts of the metropolitan area of Lima, including to the zones North, Center and South of the city, during one period of 3 to 6 months in continuous form, with measurement periods of 1 to 2 months. The houses where the measurements were made were selected considering diverse variables as antiquity, construction materials, coatings, soil type, occupational use of the monitored rooms, etc. The measurements were realized in basements, first and second floor of the residences. For the Radon-222 measurements passive detectors of cellulose nitrate (Lr-115) were used. The procedure of data collection, dosimeters reading and the measurement results are shown in this work; this monitoring is the first one that is carried out in this city. The results are only indicators of the present radon rate, by the detectors type not is possible to discriminate the presence of the Radon-222 descendants. (Author)

  13. Determination of concentration of radon, volatile organic compounds (VOC) and water chemistry in springs near to Popocatepetl volcano; Determinacion de la concentracion de radon, VOCs y Quimica del agua en manantiales cercanos al volcan Popocatepetl

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Segovia, N.; Lopez M, B.E.; Cisniega, G. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Valdes, C.; Armienta, M.A.; Mena, M. [Instituto de Geofisica, UNAM, 04510 Mexico D.F. (Mexico)

    2004-07-01

    Popocatepetl volcano is a high-risk active volcano in Central Mexico where the highest population density in the country is settled. Radon in the soil and groundwater together with water chemistry from samples of nearby springs is analysed as a function of the 2002-2003 volcanic activity. Soil radon indicated fluctuations related both the meteorological parameters and sporadic explosive events. Groundwater radon showed essentially differences in concentration due to the specific characteristics of the studied springs. Water chemistry showed stability along the monitoring period indicating also differences between springs. No anthropogenic pollution from volatile organic compounds was observed. (Author)

  14. Concentraciones traza de metales en especies marinas de la bahía de Huarmey, Ancash, Perú

    Directory of Open Access Journals (Sweden)

    María E. Jacinto

    2013-04-01

    Full Text Available Se determinaron las concentraciones traza de cadmio, cobre, plomo y zinc, en músculos y vísceras del caracol (Stramonita T. chocolata, el cangrejo peludo (Cancer setosus, la cabrilla (Paralabrax humeralis, el chorito (Semimytilus algosus, la lapa (Fissurella sp. y el chitón (Chiton spp., indeterminado; colectados en octubre 2001 en la bahía de Huarmey, Ancash, Perú. Los órganos seleccionados fueron liofi lizados y sometidos a digestión ácida según método CEM USA 1994 y analizados por espectrofotometría de absorción atómica. Las menores concentraciones de cadmio (0,63 μg/g, cobre (1,87 μg/g y zinc (1,70 μg/g, se encontraron en el músculo de P. humeralis; mientras que valores máximos de zinc (24,16 μg/g se observaron en vísceras del T. chocolata y de cobre (28,0 μg/g en músculo de Chiton spp. Las concentraciones halladas estuvieron dentro de los límites internacionales establecidos por algunos países (Nauen, 1983.

  15. Evaluation of the open vial method in the radon measurement; Evaluacion del metodo del vial abierto en la medicion de radon

    Energy Technology Data Exchange (ETDEWEB)

    Lopez del Rio, H.; Davila R, J. I.; Mireles G, F., E-mail: hlopezdelrio@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-10-15

    The open vial method is a simple technique, under-utilized but that take advantage of the great radon solubility in organic solvents, therefore applies in the measurement of the radon concentration exhaled in soil. The method consists on the exposition to the gas radon of an open vial with scintillating solution. An integral mathematical model for indoors that describes the emanation processes and gas radon exhalation was developed, as well as the radon dissolution in the scintillation liquid, besides obtaining the characteristic parameters of the experimental system proposed for the radon concentration calculation exhaled by soils. Two experimental arrangements were designed with exposition cameras of 12 and 6 L and quantity of different soil. The open vial was prepared with a mixture of 8 ml of deionized water and 12 ml of scintillation liquid OptiPhase Hi Safe 3 in polyethylene vials; the measurements of the dissolved radon were carried out in scintillation liquid equipment. As a result, on average 2.0% of the exhaled radon is dissolved in the open vial and the dissolved fraction is independent of the experimental arrangement. Also was observed that the exposition time does not affect the radon dissolution significantly, in correspondence with the reported in the literature. (Author)

  16. Measure of exposure of short-lived radon products using an alpha spectrometer for measuring indoor aerosol activity concentration and dose evaluation; Misure di esposizione ai prodotti di decadimento del radon a breve vita tramite uno spettrometro alfa per la misura dell'attivita' del particolato atmosferico indoor e valutazioni dosimetriche

    Energy Technology Data Exchange (ETDEWEB)

    Berico, M.; Castellani, C.M.; Formignani, M. [ENEA, Divisione Protezione dell' Uomo e degli Ecosistemi, Centro Ricerche Ezio Clementel, Bologna (Italy); Mariotti, F. [Bologna Univ., Bologna (Italy). Dipt. di Fisica

    2001-07-01

    A new italian law introduces the regulation of occupational exposure to radon. To evaluate the inhalation of radon daughters by the workers a sampling device has been assembled with the aim of evaluation of unattached and aerosol attached radon daughters' fractions. The instrument, based on selection of the aerosuspended particles by means of a wire screen type battery and subsequent collection on a total filter, allows to describe the behaviour of both fractions using defined temporal pattern of collecting particles and counting them by alpha spectroscopy. A measurement campaign to test the radon daughter dichotomous spectrometer in comparison with a commercial Radon Working Level meter, has been performed in a research laboratory of central Italy affected by high radon concentrations. The radon concentration during the measurement campaign has been also measured. The equilibrium factor F{sub e}q ad the attachment factor fp have been evaluated during 3 days campaign. Using the measured mean parameters (radon concentration, F{sub e}q, f{sub p}) the dose evaluation for workers using dosimetric approach has been performed. A comparison between the epidemiologic approach, based on the radon concentration, and dosimetric approach is also presented. [Italian] L'esposizione a radon in ambiente lavorativo e la conseguente inalazione dei suoi prodotti di decadimento in forma particolata e' oggetto di una recente normativa italiana in materia di protezione dalle radiazioni ionizzanti. Per rispondere a questa necessita', presso l'Istituto per la Radioprotezione dell'ENEA di Bologna e' stato progettato e realizzato uno spettrometro alfa per la misura della progenie del radon con la finalita' di valutare, su brevi periodi di tempo, la concentrazione individuale dei suoi prodotti di decadimento e, con l'impiego di batterie a diffusione a reti, consentire inoltre la discriminazione della concentrazione della frazione attaccata e non

  17. Molecular analysis of tooth enamel by Raman spectroscopy after treatment with bleaching agents at different concentrations; Analisis molecular del esmalte dental por medio de espectroscopia Raman despues del tratamiento con agentes blanqueadores a diferentes concentraciones

    Energy Technology Data Exchange (ETDEWEB)

    Duran Sedo, Randall; Obando Rosabal, Sofia; Saenz Bonilla, Paola; Soto Aguilar, Calendy; Vasquez Rodriguez, Amaya

    2014-07-01

    The changes in the concentration of the v1 phosphate molecule of the surface of dentin enamel are treated and researched with bleaching agents of chemical activation to basis of hydrogen peroxide than 9,5% and 14% and carbamide peroxide than 38%, for a period of 28 days. Raman spectroscopy was used and 30 dental pieces extracted, of which, were to be free of blemishes and pigmentations, without possessing fractures of the enamel, decay nor any other type of defect. The Raman spectrum was obtained of each dental piece prior to the application of bleaching agents. The specimens were separated into three experimental groups according to the concentration of whitening. The concentration of the v1 phosphate molecule was measured in the tooth enamel to the second and fourth week of treatment. In addition, ANOVA was performed for respective measurements (p≤0.05). A reduction of the v1 phosphate molecule were observed during and after the bleaching process in the experimental groups that have used of hydrogen peroxide to 14% and carbamide peroxide 38%. In the group of hydrogen peroxide to 9,5% has remained unproven a significant reduction. Within the limitations of this study is concluded that the bleaching agent causes a loss of v1 phosphate. This loss has been greater in the whitening of higher concentration. In spite, that the possible effect remineralizing of the saliva on a teeth whitening process has been unevaluated, it is recommended using during and after the treatment, toothpastes, mouthwashes, chewing gums, dental floss, among others, that contain ACP to help to cushion the potential loss of phosphate from tooth enamel. (author) [Spanish] Los cambios en la concentracion de la molecula de fosfato v1 de la superficie del esmalte dental son tratados e investigados con agentes blanqueadores de activacion quimica a base de peroxido de hidrogeno al 9,5% y 14% y peroxido de carbamida al 38%, por un periodo de 28 dias. Espectroscopia Raman fue utilizada y 30 piezas

  18. CRECIMIENTO Y EFICIENCIA FOTOSINTÉTICA DE Ludwigia decurrens Walter (ONAGRACEAE BAJO DIFERENTES CONCENTRACIONES DE NITRÓGENO

    Directory of Open Access Journals (Sweden)

    MARIA ANGÉLICA SANCLEMENTE

    2008-01-01

    Full Text Available En el presente estudio se evaluó el crecimiento y la eficiencia fotosintética de Ludwigia decurrens (Onagraceae, a partir de la estimación de la fluorescencia de la clorofila bajo diferentes concentraciones de nitrógeno (0 mg/L, 465 mg/L y 930 mg/L en condiciones de laboratorio. Como parámetros de crecimiento se utilizaron la longitud total del tallo y el área foliar. Durante el periodo de estudio se observó un incremento en el crecimiento y la eficiencia quántica con el aumento en la concentración de nitrógeno. Sin embargo, no se presentaron diferencias significativas (p<0,05 en los valores de fluorescencia de la clorofila entre los tratamientos. Los resultados del comportamiento de la eficiencia fotosintética (Fv/Fm y el crecimiento de las plantas tratadas con diferentes concentraciones de nitrógeno, demuestran que la macrófita Ludwigia decurrens crece en ambientes relativamente altos de nitrógeno.

  19. Biological radiation effects of Radon in Drosophila; Efectos biologicos del radon en Drosophila

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel P, A E

    1996-12-31

    In order to contribute to the knowledge on the effects of radon and its decay products, the aim of this investigation is to study the biological effects of radon using Drosophila melanogaster throught the somatic mutation and recombination test (SMART) and the analysis of some adaptative factors exposing larvaes to controlled radon atmosphers, considering that this insect could be used as biological monitor. Using the somatic mutation test a mutagenic effect was observed proportional to radon concentration, into an interval of 1 {+-} 0.3 to 111 {+-} 7.4 KBq/m{sup 3} equivalent to doses under 0.0106 Gy. The correlation analysis gives a linear (r=0.80) relationship with a positive slope of 0.2217. The same happens when gamma rays are used in the interval of 1 to 20 Gy, given a linear dose-dependent effect (r=0.878) is obtained; nevetheless the slop is smaller (m=0.003) than for radon. Analysing the results of adaptative factors of the nine exposed generations, it was found that probably radon exposition induced dominant lethals during gametogenesis or/and a selection of the more component gamets of the treated individuals in larval state. It was reflected in the significant decrease on fecundity of the generation exposed. Nevertheless the laying eggs had an increase in egg-to-adult viability and the develop velocity was higher than in control for 3 KBq/m{sup 3}, this suggest that radon concentrations used were able to induce repair mechanisms. These data agree with the Hormesis hypothesis that says: low doses have positive effects on health. It was not possible to obtain a dose-effect relationship except with the develop velocity where it was found a dose-effect inverse proportion. In conclusion, Drosophila melanogaster could be a good system to obtain in vivo damaged induction concentration dependent of radon and its decay products, as well as to study the effects in an exposed population by the analysis of adaptative factors. (Author).

  20. Cambios en las concentraciones de compuestos organoclorados en las mujeres de Flix, Tarragona

    Directory of Open Access Journals (Sweden)

    Ribas-Fitó N.

    2003-01-01

    Full Text Available La población de Flix (comarca de la Ribera del Ebro, Tarragona se encuentra altamente expuesta a hexaclorobenceno (HCB debido a la proximidad de una empresa electroquímica. Aunque los niveles de contaminación por HCB en esta población continúan siendo elevados, se ha observado que las concentraciones en sangre venosa de las mujeres de 18-40 años en 1997-1999 fueron un 61% más bajos que en 1994 (4,1 ng/ml frente a 10,6 ng/ml. Las concentraciones de diclorodifenil dicloroetano (p,p'-DDE y betahexaclorociclohexano (ß-HCH tambiιn mostraron esta tendencia a la baja, aunque su disminuciσn no fue estadνsticamente significativa. Por el contrario, los niveles de bifenilos policlorados (PCB en 1997-1999 aumentaron con relaciσn a 1994, aunque la diferencia no fue estadísticamente significativa.

  1. The radon gas. An air pollutant El gas radón como contaminante atmosférico

    Directory of Open Access Journals (Sweden)

    José Luis Arteche

    2010-12-01

    Full Text Available In this work different aspects about the problem of the radon in dwellings are approached. This gas of natural origin is virtually present in all the soils in the earth’s crust due to the presence of uranium and radium in the composition of them. Depending on architectural factors and of occupancy habits of the house, high concentrations of this gas can be reached indoors. In these situations, there is a quantifiable increment of the risk of developing lung cancer in the inhabitants of the housing. In the last years the methodological improvements in the realization of epidemiologic studies have led to the obtaining of scientific evidences about the relationship between the presence of indoor radon and the risk of lung cancer. This relationship, found years ago in workers of uranium mines, has been corroborated in the case of the residential radon by the light of several recent meta-analysis performed on groups of epidemiologic studies. More than 6.000 radon measurements have been carried out in Spain during the last 25 years. A summary of the results obtained from the main national radon surveys are also presented, as well as the criteria recently established by the Spanish Nuclear Safety Council concerning radon action levels in dwellings and workplaces.En este trabajo se abordan distintos aspectos acerca de la problemática del radón en viviendas. Este gas de origen natural se encuentra prácticamente en la totalidad de los suelos de la corteza terrestre debido a la presencia de uranio y radio en la composición de los mismos. En función de factores arquitectónicos y de hábitos de ocupación de la vivienda pueden alcanzarse concentraciones elevadas del gas en interiores. En estas situaciones existe un incremento cuantificable del riesgo de desarrollar cáncer de pulmón en los habitantes de la vivienda. En los últimos años, las mejoras metodológicas en la realización de estudios epidemiológicos han conducido a la obtención de

  2. Biological effects of radon in Drosophila; Efectos biologicos del radon en Drosophila

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel P, A E; Tavera D, L; Cruces M, M P; Arceo M, C; Rosa D, M.E. de la

    1992-04-15

    The main objective of this investigation, is to study the biological effects of the Radon-222 at low dose in 'Drosophila melanogaster'. It is necessary to mention that these effects will analyze from the genetic point of view for: 1) To evaluate in which form the Radon-222 to low dose it influences in some genetic components of the adaptation in Drosophila, such as: fecundity, viability egg-adult and sex proportion. 2) To evaluate which is the genetic effect that induces the Radon to low dose by means of the SMART technique in Drosophila melanogaster, and this way to try of to identify which is the possible mechanism that causes the genetic damage to somatic level. The carried out investigation was divided in three stages: 1. Tests to the vacuum resistance. 2. Test of somatic mutation, and 3. Determination of the presence of radon daughters on the adult of Drosophila. It is necessary to point out that all the experiments were made by triplicate and in each one of them was placed detectors in preset places. Those obtained results are presented inside the 4 charts included in the present work. (Author)

  3. Biological effects of radon in Drosophila; Efectos biologicos del radon en Drosophila

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel P, A.E.; Tavera D, L.; Cruces M, M.P.; Arceo M, C.; Rosa D, M.E. de la

    1992-04-15

    The main objective of this investigation, is to study the biological effects of the Radon-222 at low dose in 'Drosophila melanogaster'. It is necessary to mention that these effects will analyze from the genetic point of view for: 1) To evaluate in which form the Radon-222 to low dose it influences in some genetic components of the adaptation in Drosophila, such as: fecundity, viability egg-adult and sex proportion. 2) To evaluate which is the genetic effect that induces the Radon to low dose by means of the SMART technique in Drosophila melanogaster, and this way to try of to identify which is the possible mechanism that causes the genetic damage to somatic level. The carried out investigation was divided in three stages: 1. Tests to the vacuum resistance. 2. Test of somatic mutation, and 3. Determination of the presence of radon daughters on the adult of Drosophila. It is necessary to point out that all the experiments were made by triplicate and in each one of them was placed detectors in preset places. Those obtained results are presented inside the 4 charts included in the present work. (Author)

  4. Concentraciones plasmáticas de cortisol materno secundarias al uso de betametasona para la maduración pulmonar fetal

    Directory of Open Access Journals (Sweden)

    Keibis Jiménez Castillejo

    2014-09-01

    Full Text Available Resumen (español El objetivo de la investigación fue determinar las concentraciones plasmáticas de cortisol materno secundarias al uso de betametasona para la maduración pulmonar fetal. Se realizó una investigación con un diseño tipo cuasi-experimental y una muestra no probabilística intencional de 106 pacientes que acudieron a la consulta pre-natal de alto riesgo del Hospital Central “Dr. Urquinaona". Una vez seleccionadas las pacientes se le administró inyecciones intramusculares de betametasona (12 mg por dos días consecutivos. Las mediciones se realizaron en tres ocasiones: La primera medición, antes de la administración de la primera dosis de betametasona; la segunda medición, 24 horas después de la segunda y última inyección; y la tercera medición, siete días luego de la administración de la última dosis de betametasona. Se observó que las inyecciones con betametasona producían disminuciones de las concentraciones plasmáticas de cortisol materno, ya que el valor de la primera medición fue de 30,1 +/- 9,4 picogramos/dL, las concentraciones disminuyeron a 5,6 +/- 1,9 picogramos/dL durante la segunda medición y luego aumentaron a 23,2 +/- 4,2 picogramos/dL a la tercera medición. Las variaciones de las concentraciones de cortisol de la segunda y tercera medición se consideraron estadísticamente significativas al compararlas con las concentraciones iniciales (p = 0,001. Se concluye que el uso de betametasona para inducir la maduración pulmonar fetal produce disminución significativa en las concentraciones plasmáticas de cortisol materno

  5. Concentraciones de aminoácidos maternos secundarias al uso de betametasona para la

    OpenAIRE

    Keibis Jiménez-Castillejo; Eduardo Reyna-Villasmil; Duly Torres- Cepeda; Joel Santos-Bolívar; Jorly Mejia-Montilla

    2016-01-01

    El objetivo de la investigación fue determinar las concentraciones plasmáticas de aminoácidos maternos secundarias al uso de betametasona para la maduración pulmonar fetal. Se realizó una investigación con un diseño tipo cuasi-experimental y una muestra no probabilística intencional de 106 pacientes que acudieron a la Consulta Pe-Natal de Alto Riesgo del Hospital Central “Dr. Urquinaona". A las pacientes seleccionadas se les administró betametasona intramuscular (12 mg) por dos dí...

  6. Radon risk in the house; Il rischio radon nelle abitazioni

    Energy Technology Data Exchange (ETDEWEB)

    Bressa, G. [Padua Univ., Padua (Italy). Dipt. di Farmacologia e Anestesiologia, Lab. di Tossicologia

    2001-04-01

    Radon was discovered in 1900, but its potential dangerousness for man was fully understood only in 1950. Being a radioactive natural gas - and therefore particularly dangerous - radon results from the long decay chain of radionuclides, such as thorium and radium. Some igneous rocks (granite, tufa and lava) as well as coal are considered to be the main sources of this radionuclide. A number of epidemiologic studies have shown the carcinogenicity of this element, particularly among miners and workers subjected to high level exposure in confined spaces such as basements, garages, cellars, etc. There are, however, some techniques to remove radon in order to reduce exposure to minimum values. [Italian] Il radon fu scoperto nel 1900, ma solo nel 1950 si comprese la sua potenziale pericolosita' per l'uomo. Il radon e' particolarmente pericoloso essendo un gas naturale radioattivo. Esso proviene dalla lunga catena di decadimento di radionuclidi come il torio e di radio. Sorgenti di tale radionuclide sono da considerarsi principalmente alcune rocce ignee (graniti, tufi e lave) e il carbone. Diversi studi epidemiologici hanno evidenziato la cancerogenicita' di tale elemento, specie tra i minatori e soggetti esposti ad alti livelli in ambienti confinati quali scantinati, garage sotterranei, ecc.. Esistono comunque tecniche di intervento per la rimozione del gas radon in modo tale da ridurre l'esposizione a valori minimi.

  7. Contaminación atmosférica y calidad del aire en Madrid: Análisis de las concentraciones de SO2, CO, NO2, ozono y PM10 (1980-2003

    Directory of Open Access Journals (Sweden)

    Fernández García, Felipe

    2005-12-01

    Full Text Available In this paper we analyse the limit values of the new EU air quality Directive (1999/30/EC for SO2; CO; NO2; PM10 and O3 pollutans. The annual average concentrations are decreasing from 1980 to 1990; from 1990 to 2003, NO2 and PM10 have been stable, SO2 and CO continuing downwards and the ozone has increased. Concentrations of NO2 and PM10 are higher of limit values in more of 96% of the urban stations, by contrast the highest concentrations of ozone occurs in the surronundings.[es] En este artículo analizamos la calidad del aire en Madrid a partir de los límites propuestos por la Directiva europea (1999/30/EC para el SO2, CO, NO2, ozono y PM10. Los resultados más importantes han sido: una clara tendencia descendente en las concentraciones medias entre 1980 y 1990; a partir de ese año las concentraciones de NO2 y PM10 permanecen estables, las del SO2 y del CO continúan descendiendo y el ozono aumenta. En el periodo 2001 y 2003 las medias de NO2 y PM10 superan los valores límites en más del 96% de las estaciones urbanas, mientras que los mayores valores del ozono se registran en las áreas suburbanas. [fr] Dans cet article nous avons utilisé les valeurs limites proposées par la Directive Européenne (1999/30/EC pour le SO2; CO; NO2; PM10et l'ozone. Les principaux résultats sont : les concentrations moyennes annuelles ont diminué entre 1980 et 1990 ; entre 1990 et 2003, les concentrations de NO2 et de PM10 se sont stabilisées, celles de SO2 et de CO ont continué la diminution, et la tendance de l'ozone est positive. NO2 et PM10 ont dépassé les limites dans le 96% des stations urbaines, mais l´ozone est au maximum dans les zones suburbaines prochaines.

  8. Efecto de la raza y la edad sobre las concentraciones de hormonas tiroideas T3 y T4 de bovinos en condiciones tropicales

    Directory of Open Access Journals (Sweden)

    Rómulo Campos Gaona

    2008-06-01

    Full Text Available Para estudiar el efecto en condiciones de trópico seco de la edad y del grupo racial sobre las concentraciones séricas de las hormonas tiroideas T3 y T4, se muestrearon 158 animales de los grupos raciales Holstein, Lucerna, Hartón del Valle, Cebú Brahman y mestizo F1 (Cebú Brahman x Pardo Suizo, distribuidos en cuatro grupos de edad desde el nacimiento hasta el destete (8 meses. La concentración media de T3 fue 2.25 mmol/L y la de T4, 57.37 mmol/L. La correlación entre T3 y T4 fue de 0.53. Se encontró diferencia estadísticamente significativa para el efecto grupo racial, grupo de edad (P<0.001 pero no para la interacción grupo racial x edad (p=0.286. Los grupos raciales con concentraciones más elevadas fueron Holstein y Lucerna; la concentración más baja se presentó en los bovinos mestizos. La mayor concentración de hormonas tiroideas según la edad ocurrió en recién nacidos, luego descendió progresiva y linealmente. El trabajo encontró que en condiciones de trópico seco, en zona límite de termoneutralidad según el índice ITH, los bovinos jóvenes presentanron diferencias marcadas en las concentraciones de hormonas tiroideas

  9. EVALUACIÓN DEL EFECTO DEL HIDROCARBURO FENANTRENO SOBRE EL CRECIMIENTO DE Chlorella vulgaris (CHLORELLACEAE

    Directory of Open Access Journals (Sweden)

    Angélica María Otero-Paternina

    2013-01-01

    Full Text Available Se evaluó el efecto del hidrocarburo policíclico aromático fenantreno sobre el crecimiento de la microalga Chlorella vulgaris  bajo condiciones de laboratorio. Las microalgas fueron expuestas a diferentes concentraciones de fenantreno (0, 1, 10, 100, 1000 y 10000 μg/l. El tiempo de exposición fue de 72 h, determinándose diariamente la densidad algal mediante recuento en cámara de Neubauer. Se determinó la tasa promedio de crecimiento, la biomasa total y el porcentaje de inhibición de la biomasa. También se evaluó el contenido de clorofila a, al inicio y final del experimento. Los ensayos fueron realizados en recipientes de vidrio de 0,4 l, utilizando como medio de cultivo fertilizante inorgánico del complejo NPK (REMITAL® m – 17-6-18 a razón de 1 g/l. Los resultados mostraron que el fenantreno inhibió progresivamente el crecimiento de la microalga, observándose el menor crecimiento celular en el medio con la mayor concentración de fenantreno, el cual alcanzó un porcentaje de inhibición del crecimiento del 59 %. Las tasas de crecimiento diario se mantuvieron relativamente constantes en los demás tratamientos. La concentración de clorofila a, medida mediante espectrofotometría, no se afectó por las diferentes concentraciones del hidrocarburo. En conclusión, el crecimiento de la microalga C. vulgaris  puede afectarse negativamente por la exposición a concentraciones nominales superiores a 1 μg/l de fenantreno.

  10. Genetic, dietary, and other lifestyle determinants of serum homocysteine levels in young adults in Costa Rica Factores genéticos y alimentarios y otros aspectos del estilo de vida que determinan las concentraciones séricas de homocisteína en adultos jóvenes en Costa Rica

    Directory of Open Access Journals (Sweden)

    Ileana Holst-Schumacher

    2005-04-01

    Full Text Available OBJECTIVE: Elevated serum total homocysteine (tHcy is considered an independent risk factor for cardiovascular disease. The objective of this study was to develop the first-ever information on the prevalence of hyperhomocysteinemia and its determinants in a population in Costa Rica. METHODS: A cross-sectional study was conducted to determine serum levels of tHcy, vitamin B12, folate, and creatinine, as well as the presence of the genotype TT for the methylenetetrahydrofolate reductase (MTHFR enzyme. Additionally, dietary vitamin intakes and other lifestyle risk factors were assessed. A total of 399 Costa Rican adults from the central valley of the country (where the capital city, San José, is located, aged 20 to 40 years, participated in this study in the year 2000. Analyses of variance were performed for continuous variables, and the chi-square test was used for categorical data. Spearman correlation tests were calculated to determine associations between variables. Three linear regression analyses and one binary logistic model were developed in order to determine the predictors for homocysteine levels in the population studied. RESULTS: The overall prevalence of hyperhomocysteinemia (> 15 µmol/L in the population was 6%, 31% of the population were in the range of 10 to 15 µmol/L, 29% had the genotype TT for the enzyme MTHFR, 18% presented a vitamin B12 deficiency (OBJETIVO: La elevación de las concentraciones séricas de homocisteína total (tHci se considera un factor que influye de forma independiente en el riesgo de sufrir trastornos cardiovasculares. El objetivo del presente estudio ha sido aportar los primeros datos que jamás se han reunido acerca de la prevalencia de hiperhomocisteinemia y sus factores determinantes en una población costarricense. MÉTODOS: Se llevó a cabo un estudio transversal a fin de determinar las concentraciones séricas de tHci, vitamina B12, folato y creatinina, así como la presencia del genotipo TT

  11. Study of the effects of radon in three biological systems; Estudio de los efectos del radon en tres sistemas biologicos

    Energy Technology Data Exchange (ETDEWEB)

    Tavera, L. [Instituto Mexicano del Petroleo, Av. Eje Central Lazaro Cardenas No. 152, Edif. 23, Col. San Mateo Atepehuacan, 07730 Mexico D.F. (Mexico); Balcazar, M.; Lopez, A.; Brena, M. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Rosa, M.E. De la [Facultad de Quimica, UNAM, 04510 Mexico D.F. (Mexico); Villalobos P, R. [Centro de Estudios de la Atmosfera, UNAM, 04510 Mexico D.F. (Mexico)

    2002-07-01

    The radon and its decay products are responsible of the 3/4 parts of the exposure of the persons to the environmental radiation. The discovery at the end of XIX Century of the illnesses, mainly of cancer, which appeared in the presence of radon, lead to an accelerated growing of the radon studies: monitoring, dosimetry, effects on the persons, etc. Several epidemiological studies of radon in miners and population in general have been realized; advancing in the knowledge about the concentration-lung cancer risk relationship, but with discrepancies in the results depending on the concentration levels. Therefor, studies which consuming time, efforts and money go on doing. The research of the radon effects in biological systems different to human, allows to realize studies in less time, in controlled conditions and generally at lower cost, generating information about the alpha radiation effects in the cellular field. Therefor it was decided to study the response of three biological systems exposed to radon: an unicellular bacteria Escherichia Coli which was exposed directly to alpha particles from an electrodeposited source for determining the sensitivity limit of the chose technique. A plant, Tradescantia, for studying the cytogenetic effect of the system exposed to controlled concentrations of radon. An insect, Drosophila Melanogaster, for studying the genetic effects and the accumulated effects in several generations exposed to radon. In this work the experimental settlements are presented for the expositions of the systems and the biological results commenting the importance of these. (Author)

  12. Exposure to radon in Cuban tourist caves

    International Nuclear Information System (INIS)

    Carrazana Gonzalez, Jorge; Dominguez Ley, Orlando; Gil Castillo, Reinaldo; Molerio Leon, Leslie

    2008-01-01

    With the objective of estimating the dose, due to Radon-222, received by tour guides and other people who work inside some of the most important tourist caves in the Republic of Cuba, measurements of radon concentrations were carried out in four of these caves: Santo Tomas Cave, Tapiada Cave, Del Indio Cave and Jose Miguel Cave. All these caves are located in the Vinales Valley (Pinar del Rio City), a very important tourist area in the country. The relationship among radon concentration, the concentration of natural radionuclides inside the caves and the geologic characteristics of the specific locations was analyzed. In order to select the most appropriates measurement places, different criteria were taken into account: representatives points of the geology of the caves, level of gamma radiation, exchange of air, places of work inside the caves (cafeterias, restaurants and shops) and places more frequently visited by tour guides. The maximum radon concentration was found in Jose Miguel Cave with a value of 220 Bq/m 3 . The measurement of gamma dose rate inside the caves was carried out with a scintillation detector type Scintrex BGS-3 previously calibrated at SSI, Sweden. The radon concentrations were measured with the equipment Alpha Guard PQ2000/MC50 and SARAD RM2000, both also calibrated at SSI, Sweden. The obtained results indicated that, in the studied caves, the annual dose is not greater than 1 mSv considering a work year of 2000 hours. (author)

  13. Efecto hipolipidémico del extracto acuoso de las hojas de Artocarpus altilis "árbol del pan" en Rattus norvegicus con hiperlipidemia inducida

    Directory of Open Access Journals (Sweden)

    Julio Campos Florián

    2013-01-01

    Full Text Available La presente investigación tuvo como objetivo demostrar la actividad hipolipidémica del extracto acuoso de las hojas del árbol del pan, Artocarpus altilis, en un modelo de hiperlipidemia aguda inducida con tritón X-305, utilizando como especímenes Rattus norvegicus machos, peso promedio 204,5 g, a los que se les administró por vía oral 0,05 g/100 g y 0,2 g/100 g del extracto acuoso de A. altilis; se incluyó un grupo control negativo que recibió solución salina fisiológica y un grupo control positivo hiperlipidémico. Luego de 24 horas de administrar los tratamientos, se realizaron las mediciones en suero de las concentraciones de colesterol y triglicéridos. Encontramos reducciones significativas (p < 0,01 tanto de las cifras de colesterol, como de triglicéridos en relación a las concentraciones obtenidas en el grupo control positivo. También encontramos diferencia significativa (p < 0,01 entre las concentraciones de triglicéridos de los animales tratados con las dos dosis del extracto acuoso de A. altilis. Concluimos que el extracto acuoso de las hojas de A. altilis presenta efecto hipolipidémico a las dosis ensayadas para el modelo de hiperlipidemia inducida con tritón X-305.

  14. Eficiencia del extracto de Ricinus communis para el control del mosquito Culex

    Directory of Open Access Journals (Sweden)

    Diego Tomás Corradine Mora

    2014-05-01

    Full Text Available Este artículo evaluó el efecto insecticida del extracto de Ricinus communis sobre larvas de mosquitos Culex. A las 24 h la mortalidad es de 8.33 % con dosis de 1 mL del extracto en una concentración de 500 ppm; 35 % en dosis de 1 mL de una concentración de 1000 ppm; 65 % en dosis de 5 mL de una concentración de 1000 ppm; 98.33 % con 10 mL en concentración de 1000 ppm; testigos 3.3 %. Cuando se evaluó el efecto insecticida del extracto aplicado por aspersión en concentraciones de 500, 750 y 1000 ppm, se consiguieron mortalidades de 18.33, 36.66 y 48.32 %, respectivamente. Ninguna de las concentraciones evaluadas alcanzó el cien por ciento de letalidad. En la prueba de semicampo, solo se logró una mortalidad de 9 %. Se evidenció que el extracto tiene un mejor efecto insecticida para el control de ejemplares inmaduros en estado larvario que sobre los adultos.

  15. Concentraciones de homocisteína y perfil lipídico en preeclámpticas

    OpenAIRE

    Reyna-Villasmil, Eduardo; Torres-Cepeda, Duly; Peña-Paredes, Elvia; Mejia-Montilla, Jorly; Reyna-Villasmil, Nadia; González-Rodríguez, Peggy

    2008-01-01

    El objetivo de la investigación fue comparar las concentraciones plasmáticas de homocisteína y perfil lipídico en preeclámpticas y controles además establecer la relación entre la homocisteína y las concentraciones de colesterol, triglicéridos y lipoproteínas. Setenta pacientes fueron seleccionadas y divididas en dos grupos, preeclámpticas (grupo A) y embarazadas normotensas (grupo B), consideradas como controles, estudiadas en forma consecutiva. Se midieron las concentraciones de colesterol ...

  16. Evaluación de diferentes concentraciones de algunos reguladores de crecimiento en la multiplicación y enraizamiento in vitro de Limonium var. Misty blue

    Directory of Open Access Journals (Sweden)

    Chamorro Albeiro Hernán

    2007-06-01

    Full Text Available

    Se evaluaron diferentes concentraciones de reguladores de crecimiento en las fases de multiplicación y enraizamiento in vitro de Limonium var. Misty blue, las cuales son bajas en esta especie. Se trabajó con material in vitro donado por la Empresa La Plazoleta Ltda. Se evaluaron diferentes tipos y concentraciones de citoquininas (kinetina, KIN; 6-bencilaminopurina, BAP; y thidiazuron, TDZ en la fase de multiplicación y dos tipos de auxinas (ácido indolacético, AIA; y ácido indolbutírico, AIB a diferentes concentraciones en la fase de enraizamiento in vitro. En la fase de multiplicación los mejores resultados fueron obtenidos con el uso del medio de cultivo MS (Murashige y Skoog, 1962 suplementado con KIN o BAP a 0,5 mg· L-1 durante un período de cuatro (4 semanas. Se encontró que concentraciones altas de las citoquininas evaluadas en este trabajo inducen desdiferenciación celular y reducen la tasa de multiplicación, especialmente el TDZ a 0,1 mg· L-1. En la fase de enraizamiento in vitro se obtuvieron buenos resultados manteniendo las plántulas por un período de tres (3 semanas en medio MS (1962 suplementado con AIB en concentraciones entre 0,5 y 1,0 mg· L-1, lo cual consiguió un sistema radical adecuado para su posterior endurecimiento. En presencia de AIA no se formaron raíces en ninguna de las concentraciones evaluadas.

  17. Caracterización del potencial de abuso del flunitracepam

    OpenAIRE

    Martí de la Llave, Cecilia

    1997-01-01

    Con el presente estudio se pretende caracterizar el potencial de abuso del flunitracepam. La pauta de administración del flunitracepam está ajustada para alcanzar concentraciones máximas plasmáticas similares entre los dos regímenes de administración del fármaco activo, aunque a diferente velocidad; con la dosis única se alcanza la concentración máxima plasmática más rápidamente que con la dosis dividida. Cuando el voluntario recibe el fármaco activo a dosis única toma cinco cápsulas que ...

  18. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    Science.gov (United States)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  19. Evaluación del efecto tóxico del acetato plomo y el cloruro de cromo sobre el metabolismo bacterial anaerobio

    Directory of Open Access Journals (Sweden)

    Beatriz Wills

    2004-01-01

    Full Text Available Se presentan los resultados del estudio de toxicidad del cloruro de cromo (CrCl3 y el acetato de plomo (CH3COO2Pb del lodo de un reactor anaerobio de flujo ascendente y manto de lodos (UASB, aclimatado y estabilizado en el laboratorio con una solución de suero en polvo sintético; los ensayos de toxicidad se realizaron en botellas serológicas de 60 mL, se utilizaron como sustratos soluciones de ácido fórmico y suero en polvo sintético y se ensayaron concentraciones de cloruro de cromo en el rango de 1.000 a 5.000 mg/L, y de 1.000 a 10.000 mg/L para el acetato de plomo. Durante 72 horas se valoró la producción de metano en mL y el comportamiento del potencial redox en mV.Se presentaron reducciones del 50% en la producción de metano a concentraciones de 3.322 mg/L para cloruro de cromo y 1.415 mg/L para el acetato de plomo cuando el sustrato fue ácido fórmico, y a 2.291 mg/L para el cloruro de cromo y 1.982 mg/L para el acetato de plomo cuando el sustrato fue suero en polvo sintético.En síntesis, el artículo demuestra que las bacterias metanogénicas tienen un grado de resistencia cuantificable con respecto a las diferentes concentraciones de metales aplicados

  20. Radon soil increases before volcano-tectonic earthquakes in Colombia

    International Nuclear Information System (INIS)

    Garzon, G.; Serna, D.; Diago, J.; Moran, C.

    2003-01-01

    Continuous studies of radon concentration changes in soils for the purpose of earthquake monitoring have been carried out in three colombian districts and in the edifices of Galeras and nevado del Ruiz volcanoes since 1995. In zones of active faulting have been measured radon soil emissions between 1000 and 2500 pCi/L. In an intersection of two active geological faults have been measured levels of 25 000 pCi/L. In the present work appears a compilation of examples of the registered anomalous radon emissions in several stations before earthquakes of tectonic character. Examples of registered radon increases before: (1) events of magnitudes between 2 and 4; (2) the occurrence of seismic swarms; and (3) the Quindio (Colombia) earthquake (M w = 6, 2) of January 1999, are described. A model of transport mechanism for the studied isotopes is presented. (orig.)

  1. Inhibidores de la germinación en el residuo seco del tallo del amaranto (Amaranthus hypochondriacus)

    OpenAIRE

    Tejeda-Sartorius, Olga; Escalante-Estrada, J. Alberto; Soto-Hernández, Marcos; Rodríguez-González, Ma. Teresa; Vibrans, Heike; Ramírez-Guzmán, Martha E.

    2004-01-01

    Se evaluó el efecto del extracto acuoso del residuo seco del tallo del amaranto (Amaranthus hypochondriacus L. var. Azteca) a diferentes concentraciones, en la germinación y longitud de radícula y vástago de Amaranthus hybridus L. Dicho extracto, a 108 y 54 ppm inhibió la germinación de la especie en 100% y 68.42%, respectivamente, disminuyendo significativamente la longitud del vástago y la radícula, cuando la inhibición de la germinación no fue total. Se identificaron los ácidos ferúlico (A...

  2. Control of indoor radon and radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.

    1985-05-01

    There are three general categories of techniques for the control of radon and radon progeny concentrations in indoor air - restriction of radon entry, reduction of indoor radon concentrations by ventilation or air cleaning, and removal of airborne radon progeny. The predominant radon entry process in most residences appears to be pressure driven flow of soil gas through cracks or other openings in the basement, slab, or subfloor. Sealing these openings or ventilation of the subslab or subfloor space are methods of reducing radon entry rates. Indoor radon concentrations may be reduced by increased ventilation. The use of charcoal filters for removal of radon gas in the indoor air by adsorption has also been proposed. Concentrations of radon progeny, which are responsible for most of the health risks associated with radon exposures, can be controlled by use of electrostatic or mechanical filtration. Air circulation can also reduce radon progeny concentrations in certain cases. This paper reviews the application and limitations of each of these control measures and discusses recent experimental results

  3. Efecto antibacteriano del extracto etanólico del botoncillo (ACMELLA REPENS sobre Porphyromona gingivalis: Estudio in Vitro

    Directory of Open Access Journals (Sweden)

    Andrea Lizbeth Chamorro Benalcázar

    2016-09-01

    Full Text Available Objetivo: Determinar el efecto antibacteriano del extracto etanólico de Botoncillo (Acmella repens en diferentes concentraciones sobre la cepa de Porphyromona gingivalis. Materiales y metodos: En el presente estudio experimental, fueron utilizadas 24 cajas Petri con agar sangre, se inoculó P. gingivalis, y se colocaron discos con diferentes concentraciones del extracto etanólico de Botoncillo (25%, 50% y 100%, como sustancias control Clorhexidina al 0,12% y suero fisiológico. A los 7 días de incubación se midieron con una regla milimetrada los halos de inhibición formados alrededor de los respectivos discos. Resultados: el extracto de Botoncillo al 100% mostró diferencias significativas en comparación con la concentración del 25% y 50% (0 < 0.05. Al comparar el extracto de Botoncillo al 100% con la Clorhexidina 0,12% se observó valores de inhibición más altos para Clorhexidina 0,12%. Conclusión: El extracto etanólico de Botoncillo presentó un efecto antibacteriano sobre P. gingivalis.

  4. Radon

    Energy Technology Data Exchange (ETDEWEB)

    Weigel, F [Muenchen Univ. (Germany, F.R.). Inst. fuer Anorganische Chemie

    1978-09-01

    The noble gas radon, formerly called emanation, was discovered a few years after radium. /sup 222/Rn, the longest-lived isotope, has a half-life of 3,82 days. This half life is so short that the experimental techniques available at present (1978) are not sufficient for a characterization of defined radon compounds, even though there are definite indications for the existence of such compounds, and one may expect such radon compounds to be even more stable than the numerous known xenon compounds. - The radon isotopes /sup 219/Rn (Actinon), /sup 220/Rn (Thoron), and /sup 222/Rn (Radon) occur in nature despite their rather short half-lives, because they are continously generated from their mothers /sup 223/Ra, /sup 224/Ra, and /sup 226/Ra, which are in secular equilibrium with long-lived isotopes /sup 235/U, /sup 238/U, and /sup 232/Th, and are in turn continously formed from these long-lived isotopes. Since the radon isotopes are gases, they enter the atmosphere and are carried for long distances with air currents. - Because radon is so short-lived, its practical applications are rather limited. For medical applications, small sealed glass tubes filled with radon are used as radiation sources after the radon has decayed, because the whole series of Po-, Bi-, and Pb-isotopes of the radium decay chain are formed, whose penetrating radiation is useful for therapy. When solids are spiked with Ra isotopes, radon is evolved at a constant rate. On heating such solids, phase transitions show up by sudden increased radon evolution (Hahn's emanation method). - On the basis of nuclear theoretical calculations, there is hardly a chance for the discovery of a long-lived radon species. Therefore, major progress in radon chemistry is hardly to be expected in the near future.

  5. Use of the radon gas as a natural geophysical tracer; Utilizacion del gas radon como un trazador geofisico natural

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Balcazar, M.; Flores R, J.H.; Lopez M, A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2006-07-01

    In this work it is denoted the applications of the radon gas like a natural geophysical radiotracer in the different branches of the Earth Sciences (Geology, geophysics and geochemistry). It importance resides in its employment like one additional tool to register the possible occurrence of seismic events by means of radon anomalies that are presented in land movements (volcanic eruptions and presence of geothermal areas), as well as its potential in environmental works whose purpose is the evaluation of the feather of contamination in the underground water and the porous media for spills of hydrocarbons. The measurement techniques to determine the concentration of radon was carried out by means of Solid Detectors of Nuclear tracks, as well as by Liquid scintillation, Clipperton, Honeywell, AlphaGUARD. The towns where these techniques its were applied were: Mexico City, Estado de Mexico (Toluca, ININ), Jalisco (The Spring), Guerrero coast. (Author)

  6. Niveles de fondo geoquímico e influencia del marco geológico en las concentraciones edafogeoquímicas de base de suelos seleccionados de Castilla-La Mancha

    Directory of Open Access Journals (Sweden)

    Jiménez Ballesta, R.

    2010-06-01

    Full Text Available Geochemical baselines are needed for environmental legislation and political decision-making, especially in the assessment of contaminated soil. Although the term «geochemical baseline» appears in the international geochemical studies and programs, probably it has never been well defined. A geochemical baseline for an element refers to its natural variations in concentration in the superficial environment. In order to answer questions such as «what is the natural concentration of trace elements in rocks and soils of Castilla-La Mancha region?» this work seeks to establish the geochemical background, baseline pedo-geochemical concentrations and reference values for the Castilla-La Mancha region. Trace element concentrations in the study area were similar to those analysed in other areas of Spain and the world. Their baseline concentrations depend mainly on the geochemical characteristics of the bed rocks.

    La determinación de las concentraciones geoquímicas de base es necesaria para la legislación ambiental y toma de decisiones, especialmente en la evaluación de suelos contaminados. Aunque la terminología sobre concentraciones geoquímicas (variaciones naturales en la concentración en el medio ambiente de superficie, aparece en los estudios geoquímicos y programas internacionales, probablemente, nunca ha sido bien definida. Para contestar a cuestiones como ¿cuál es la concentración natural de una serie de elementos traza en suelos y rocas de Castilla-La Mancha?, se determinan el fondo geoquímico y las concentraciones edafogeoquímicas de base, a la vez que se calculan los valores umbrales de los mismos. Todos los elementos traza muestran concentraciones promedio similares con los valores de referencia para los suelos de otras zonas de España (Galicia, Andalucía, Madrid, etc., la Unión Europea y el mundo. Los patrones de distribución de las concentraciones de los elementos son principalmente influenciados por

  7. Radon

    Science.gov (United States)

    ... radon-resistant features. These features include gravel and plastic sheeting below the foundation, along with proper sealing ... lower the radon level. Detailed information about radon reduction in your home or building can be found ...

  8. PO.RA project. An analysis on gas radon concentrations in soil versus fluctuations in the groundwater table; Progetto PO.RA.. Analisi della concentrazione di gas radon nel non saturo in relazione alla soggiacenza della falda freatica

    Energy Technology Data Exchange (ETDEWEB)

    Serentha' , C.; Torretta, M. [Agenzia Regionale per la Protezione dell' Ambiente della Lombardia, Dipartimento di Monza, Monza (Italy)

    2001-09-01

    Man is daily exposed to natural radiation, mainly due to cosmic rays and natural radioactive elements, whose most important radioactive daughters are {sup 222}Rn (radon) and {sup 220}Rn (thoron). Being these ones gaseous, they can spread through the ground, reaching the atmosphere and accumulating in rooms, where their concentrations may be very high. As radon exhalation is strongly connected with the hydrogeological features of the environment, this study tried to find a relationship between fluctuations in the groundwater table and gas radon concentrations in soil, in order to try estimates of indoor radon concentrations. [Italian] L'uomo e' quotidianamente esposto ad una radioattivita' di origine naturale, dovuta principalmente ai raggi cosmici ed alla presenza di alcuni elementi radioattivi naturali, i cui discendenti radioattivi piu' importanti sono il {sup 222}Rn (radon) e il {sup 220}Rn (thoron). Tali elementi, a causa della loro natura gassosa, si possono diffondere attraverso il terreno e raggiungere l'atmosfera sovrastante; cio' puo' provocarne l'accumulo in ambienti chiusi, dando luogo a concentrazioni anche elevate con possibili conseguenze sulla salute. Poiche' l'esalazione del gas radon e' foremente legata alle caratteristiche idrogeologiche dell'ambiente, in questo lavoro si e' cercato di definire una relazione che legasse le variazioni della soggiacenza della falda freatica alle variazioni della concentrazione del gas radon nel non saturo, al fine di verificare se sia possibile effettuare un'attivita' previsionale applicabile ai rilievi di gas radon indoor.

  9. The radon

    International Nuclear Information System (INIS)

    1998-01-01

    This booklet is intended to answer briefly the most important questions about the nature and sources of radon, its pathways from environment to organism, as well as the ways to minimize its concentration in the habitat's atmosphere. The radon is a naturally appearing radioactive gas, produced through the decay of uranium and radium present in the terrestrial crust. It can be found everywhere on the planet's surface and it is emitted particularly from the granite and volcanic underground rocks as well as from certain construction materials. It is one of the agents producing pulmonary cancer, although not so dangerous as the tobacco is. The following items are elaborated in this booklet: - the place of radon in the average exposure to ionizing radiations of the French population; - the risk; - the radon in the environment (the meteorological conditions, the nature of the rocks); - radon in dwellings (radon measurements in the French dwellings, the entrance pathways of radon, the dependence of radon concentration on the profession and way of life of the inhabitants); - radon measurements; - how to reduce the radon concentration in dwellings

  10. Radon dynamics in underwater thermal radon therapy

    International Nuclear Information System (INIS)

    Lettner, H.; Hofmann, W.; Winkler, R.; Rolle, R.; Foisner, W.

    1998-01-01

    At a facility for underwater thermal radon therapy in Bad Hofgastein, experiments were carried out with the aim of establishing radon in the air exhaled by the treated patients and of radon decay products on the skin of the patients. The time course of radon concentration in the exhaled air shows a maximum a few minutes after entering the bath, then the Rn concentration remains constant over the remaining time spent in the bath. Taking into account several simplifying assumptions, the average dose to the epidermis from radon daughters is about 50 μGy. (A.K.)

  11. Radon in Schools

    Science.gov (United States)

    ... Search Search Radon Contact Us Share Radon in Schools Related Information Managing Radon in Schools Radon Measurement ... Radon Could Be a Serious Threat to Your School Chances are you've already heard of radon - ...

  12. Radon-technical design methods based on radon classification of the soil

    International Nuclear Information System (INIS)

    Kettunen, A.V.

    1993-01-01

    Radon-technical classification of the foundation soil divides the foundation soil into four classes: negligible, normal, high and very high. Separate radon-technical designing methods and radon-technical solutions have been developed for each class. On regions of negligible class, no specific radon-technical designing methods are needed. On regions of normal radon class, there is no need for actual radon-technical designing based on calculations, whereas existing radon-technical solutions can be used. On regions of high and very high radon class, a separate radon-technical designing should be performed in each case, where radon-technical solutions are designed so that expected value for indoor radon content is lower than the maximum allowable radon content. (orig.). (3 refs., 2 figs., 2 tabs.)

  13. Radon in houses due to radon in potable water

    International Nuclear Information System (INIS)

    Hess, C.T.; Korsah, J.K.; Einloth, C.J.

    1987-01-01

    Radon concentration in the air of 10 houses has been measured as a function of water use and meterological parameters such as barometric pressure, wind velocity and direction, indoor and outdoor temperature, and rainfall. Results of calibrations and data collected in winter, spring, fall, and summer are given for selected houses. Average values of radon concentration in air are from 0.80 to 77 rhoCi/1. Water use average ranges from 70 to 240 gal/day. Average potential alpha energy concentrations in these houses range from 0.02 to 1.6 working levels. The radon level due to water use ranges from 0 to 36% of the house radon from soil and water combined. The radon level change due to use of a filter on the water supply shows a 60% reduction in radon in the house. Conclusions are that water radon can be a major fraction of the radon in houses. The ratio of airborne radon concentration due to water use to the radon concentration in water is 4.5 x 10/sup -5/ - 13 x 10/sup -5/

  14. Contribution of radon and radon daughters to respiratory cancer

    International Nuclear Information System (INIS)

    Harley, N.; Samet, J.M.; Cross, F.T.; Hess, T.; Muller, J.; Thomas, D.

    1986-01-01

    This article reviews studies on the contribution of radon and radon daughters to respiratory cancer and proposes recommendations for further research, particularly a national radon survey. The steady-state outdoor radon concentration averages 200 pCi/m3, and indoor levels are about 4 times higher. The primary source of radon in homes is the underlying soil; entry depends on multiple variables and reduced ventilation for energy conservation increases indoor radon levels. Occupational exposures are expressed in units of radon daughter potential energy concentration or working level (WL). Cumulative exposure is the product of the working level and the time exposed. The unit for cumulative exposure is the working level month (WLM). The occupational standard for radon exposure is 4 WLM/year, and 2 WLM/year has been suggested as a guideline for remedial action in homes. Epidemiologic studies show that miners with cumulative radon daughter exposures somewhat below 100 WLM have excess lung cancer mortality. Some 3% to 8% of miners studied have developed lung cancer attributable to radon daughters. All of the underground mining studies show an increased risk of lung cancer with radon daughter exposure. All cell types of lung cancer increased with radon exposure. If radon and smoking act in a multiplicative manner, then the risk for smokers could be 10 times that for nonsmokers. The potential risk of lung cancer appears to be between 1 and 2 per 10,000/WLM, which yields a significant number of lung cancers as some 220 million persons in the United States are exposed on average to 10 to 20 WLM/lifetime

  15. Levels of radon gas concentration and progeny in homes of Potosi City, Bolivia to 4000 m; Niveles de concentracion de gas radon y progenie en viviendas de la Ciudad de Potosi, Bolivia a 4000 msnm

    Energy Technology Data Exchange (ETDEWEB)

    Mamani M, R. [Universidad Autonoma Tomas Frias, Carrera de Fisica, Av. del maestro s/n, Edif. Central Potosi, Villa Imperial de Potosi (Bolivia, Plurinational State of); Claros J, J. [Universidad Autonoma Tomas Frias, Facultad de Minas Potosi, Centro de Investigacion, Av. Serrudo y Arce s/n, Villa Imperial de Potosi (Bolivia, Plurinational State of); Vasquez A, R., E-mail: raulm2k13@hotmail.com [Instituto Boliviano de Biologia de Altura, Calle Hoyos 953, La Paz (Bolivia, Plurinational State of)

    2015-10-15

    Full text: In this work the presence of radon gas was determined, which is a radioactive contaminant that comes from underground, able to penetrate the houses. The danger is that when mixed air and when inhaled can cause serious damage to the lungs, for the short life time that has radon and progeny for decay, damaging the pulmonary alveoli and reducing breathing capacity of the habitants, then causing polycythemia in some cases. The study was carried out in homes in the city of Potosi, Bolivia located at 4000 m. The quantification of radon gas and progeny was performed with the equipment Alpha-Zaeller-2 (Az-2), quantification was realized in 6 zones of the city of Potosi, chosen randomly. In each zone were carried out measurements in 40 homes (2 rooms more permanent), both day and night, for a period of 3 days in two different seasons and with concentrations of average humidity of 20, 50 and 80%. The values obtained for each period vary depending on the season and 30 to 50% of the allowable values given by the EPA and Who for housing. (Author)

  16. Radon and health

    International Nuclear Information System (INIS)

    Chobanova, Nina

    2016-01-01

    Radon is radioactive noble gas that can be found in soil, water, outdoor and indoor air. Since environmental radon on average accounts for about half of all human exposure to radiation from natural sources, increasing attention has been paid to exposure to radon and its associated health risks. Many countries have introduced regulations to protect their population from radon in dwellings and workplaces. In this article are discussed main characteristics of radon, including sources of exposure, variation in radon exposure, how managing risks from radon exposure, how to measure the concentration of radon. There are results of measurements conducted under the 'National radon programme' in Bulgaria also. Key words: radon, sources of exposure, risk, cancer, measure to decrease the concentration [bg

  17. Predicting radon/radon daughter concentrations in underground mines

    International Nuclear Information System (INIS)

    Leach, V.A.

    1984-01-01

    A detailed description of a computer programme is outlined for the calculation of radon/radon daughter concentrations in air. This computer model is used to predict the radon/radon daughter concentrations in Working Level (WL) at the workplace and at the various junctions at either end of the branches in a typical ventilation network proposed for the Jabiluka mine in the Northern Territory

  18. Determination of radon in the air of housings of the Aguascalientes municipality; Determinacion de radon en el aire en viviendas del municipio de Aguascalientes

    Energy Technology Data Exchange (ETDEWEB)

    Jasso G, M.R.; Lira P, M.G.; Bonilla P, A.; Ruvalcaba S, L.; Gutierrez S, K.M.; Sandoval A, G.E. [Instituto Tecnologico de Aguascalientes, Av. Lopez Mateos 1801, 20256 Aguascalientes (Mexico); Sanchez H, L. [CNSNS, Dr. Barragan 779, 03020 Mexico D.F. (Mexico)]. e-mail: jassogonzalezre@yahoo.com.mx

    2006-07-01

    This study reports the results of the first exploratory sampling of the radon concentration in the air in a group of housings of the Aguascalientes City, Mexico. The municipality of Aguascalientes was divided in 4 sampling areas considering a total of 179 housings. In these housings, the radon concentration in the air was monitored during a period of 10 days. The results obtained in this study indicate that the radon concentration in the air of 45% of the sampling housings overcomes the concentration limit of 250 Bq/m{sup 3} suggested by the EPA. (Author)

  19. Radon in homes of the Portland, Oregon Area: Radon data from local radon testing companies collected by CRM (Continuous Radon Measurement) machines

    Science.gov (United States)

    Whitney, H.; Lindsey, K.; Linde, T.; Burns, S. F.

    2013-12-01

    Students from the Department of Geology at Portland State University paired up with the Oregon Health Authority to better understand radon gas values in homes of the Portland metropolitan area. This study focuses on radon values collected by continuous radon measurement (CRM) machines, taken by local radon testing companies. The local companies participating in this study include Alpha Environmental Services, Inc., Cascade Radon, Environmental Works, The House Detectives, LLC, and Soil Solutions Environmental Services, Inc. In total, 2491 radon readings spanning across 77 zip codes were collected from local companies in the Portland metropolitan area. The maximum value, average value, percentage of homes greater than 4 pCi/L and total rank sum was calculated and used to determine the overall radon potential for each zip code (Burns et al., 1998). A list and four maps were produced showing the results from each category. Out of the total records, 24 zip codes resulted in high radon potential and the average reading for the entire Portland Metropolitan area was 3.7 pCi/L. High potential zip codes are thought to be a result of sand and gravel (Missoula Flood deposits) and faults present in the subsurface. The CRM data was compared with both long-term and short-term data provided by the Oregon Health Authority to validate radon potentials in each zip code. If a home is located in a zip code with high or moderate radon potential across two types of data sets, it is recommended that those homes be tested for radon gas.

  20. EFECTOS DEL MERCURIO SOBRE ALGUNAS PLANTAS ACUÁTICAS TROPICALES

    OpenAIRE

    Posada, Martha Isabel; Arroyave, María del Pilar

    2006-01-01

    El presente artículo es una descripción de los efectos del mercurio sobre algunas plantas acuáticas tropicales y sobre los ecosistemas donde habitan. Adicionalmente, se recomienda un protocolo para realizar pruebas de toxicidad con la lenteja de agua (Lemna minor) y se presentan los resultados de los preensayos con diferentes concentraciones de sales de mercurio en condiciones de laboratorio. Se encontró que la biodisponibilidad del mercurio depende de factores que facilitan la disolución del...

  1. Depuración aerobia de los efluentes resultantes del proceso de biometanización del alpechín

    Directory of Open Access Journals (Sweden)

    Borja Padilla, R.

    1992-02-01

    Full Text Available A study of aerobic treatment in batch regime of the effluents produced in the olive mill wastewater biomethanation process was carried out. An 83% of effluents organic substances was removal after the third day of fermentation. The substrate removal rate follows a zero-order kinetic for high concentrations, and a first-order kinetic for low organic matter concentration, during the last days of fermentation. The kinetic parameters (qmáx and K were obtained from Michaelis- Menten model.

    Se ha efectuado un estudio del proceso de depuración aerobia, en régimen discontinuo, de los efluentes procedentes del proceso de depuración anaerobia o biometanización del alpechín. Se comprueba que el 83% de la materia orgánica presente en este efluente se elimina a partir del tercer día de fermentación. La eliminación de sustrato sigue una cinética de orden cero para altas concentraciones del mismo y una cinética de primer orden para bajas concentraciones de materia orgánica, es decir, durante los últimos días de fermentación. Se aplica el modelo de Michaelis-Menten de eliminación de sustrato para la obtención de los parámetros cinéticos qmáx y Ks que rigen este proceso.

  2. Overview of current radon and radon daughter research at LBL

    International Nuclear Information System (INIS)

    1983-01-01

    This report provides a brief summary of radon and radon daughter research at Lawrence Berkeley Laboratory. The radon and radon daughter research program has two broad goals: (1) the study of sources of radon and its subsequent transport into houses, and (2) research on the behavior of radon daughters in indoor environments. Additional research effort is directed to several auxiliary areas, including development of instrumentation and monitoring techniques, studies of indoor air movement, and measurement and control of indoor particulate concentrations

  3. Radon analyser

    International Nuclear Information System (INIS)

    1981-01-01

    The process claimed includes the steps of transferring radon gas produced by a sample to a charcoal trap, cooled to a temperature whereby the radon is absorbed by the charcoal, heating the charcoal trap to a sufficient temperature to release the radon, and transferring the radon to a counting device where the gas particles are counted

  4. CALIDAD DEL AGUA EN EL ÁREA COSTERA DE SANTA MARTA (COLOMBIA

    Directory of Open Access Journals (Sweden)

    FRANCISCO GARCÍA

    2012-01-01

    Full Text Available Se usaron técnicas de análisis estadístico multivariado, para determinar la variación temporal y espacial de la calidad del agua en la zona costera de Santa Marta, donde se ubica un emisario submarino que descarga 1 m3/s de aguas residuales domésticas. La ANOVA de dos vías, los análisis de clúster y de componentes principales mas la interpolación de krigging, fueron considerados para este análisis. En la variación temporal se encontraron diferencias que marcan en el año dos periodos de tiempos heterogéneos, de diciembre a abril la concentración de los parámetros de calidad del agua es más alta. El resto del año (mayo, junio, agosto - noviembre, exceptuando el mes de julio donde se presentaron concentraciones altas, se registran concentraciones sensiblemente inferiores. En la variación espacial se reportan dos grupos de áreas en las cuales la calidad del agua es diferente, dicha diferencia está relacionada con la cercanía a la descarga del emisario submarino.

  5. Investigations of radon and radon daughters in surficial aquifers of florida

    International Nuclear Information System (INIS)

    1991-05-01

    The principal purpose of the investigation was to test the hypothesis that radon soil flux, considered the principal source of indoor radon contamination, has an underlying relationship to the radon content of associated shallow groundwaters. The working hypothesis was that radon build-up in both soil and shallow groundwater is basically a consequence of the same factor, radon emanation from soil grains and the solid surfaces of the aquifers. Groundwater may be advantageous as an indicator of radon potential. Another object of the project was to investigate temporal and spatial trends of radon daughter products in shallow aquifers. After analyzing all of the radon soil, flux, and groundwater measurements made over the two-year study period, it is clear that while there is no direct relationship between either radon soil concentration or flux and groundwater radon. Measurements in wells where polonium is present at very high concentrations have shown that 210Po is largely unsupported by its radioactive predecessor, and that polonium is considerably more variable, in both space and time than other parameters measured in the same wells, including radon

  6. Radon dosimetry: a review of radon and radon daughter exposure conditions in dwellings and other structures

    International Nuclear Information System (INIS)

    Ryan, M.T.; Goldsmith, W.A.; Poston, J.W.; Haywood, F.F.; Witherspoon, J.P.

    1983-07-01

    Within the past few years several situations have been brought to light which indicate an increased radiation exposure of certain segments of the general population caused by human activities. The most widely publicized activities are those associated with the mining and milling of uranium in the western United States, the phosphate industry in Florida, and those potential problems represented by former Manhattan Engineer District sites. One of the primary problems involves exposure to radon and radon daughters which are released from large waste piles or, in some cases, evolve from backfill and construction materials used in homes, schools, and other buildings. This report presents a review of the available data on radon and radon daughter concentrations in dwellings and other structures. The primary objectives were to compile and tabulate pertinent radon exposure data and to prepare a statistical summary of the data which will be useful in the prediction of normal levels of radon and radon daughter concentrations in these structures. In addition, other parameters associated with radon exposure conditions are presented and discussed

  7. State of the art of technologies thermosolar to concentration; Estado del arte de las tecnologias termosolares a concentracion

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Berume, Carlos; Huacuz Villamar, Jorge M; Medrano Vaca, M. Consolacion [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    2000-07-01

    focal (tubo metalico receptor). Por el interior de este tubo circula un fluido de trabajo (aceite termico) a temperaturas de hasta 390 grados Celsius, el cual es enviado a intercambiadores de calor para producir vapor sobrecalentado para operar una turbina y generar la energia electrica y Plato Parabolico (PP), contiene una estructura formada por segmentos de espejos que conforman un paraboloide donde en su punto focal (receptor/maquina termica) incide en la radiacion reflejada y se produce energia electrica. En este documento se presenta el estado del arte de las Tecnologias Termosolares a Concentracion (YYC) que permiten identificar sus desarrollos y problematica actual. Ademas, se incluye una descripcion de las perspectivas de mercado, costos de las TTC y las perspectivas tecnologicas.

  8. Background concentrations of radon and radon daughters in Canadian homes

    International Nuclear Information System (INIS)

    McGregor, R.G.; Vasudev, P.; Letourneau, E.G.; McCullough, R.S.; Prantl, F.A.; Taniguchi, H.

    1980-01-01

    Measurements of radon and radon daughters were carried out in 14 Canadian cities on a total of 9999 homes selected in a statistically random manner. The geometric means of the different cities varied from 0.14 to 0.88 pCi/l. for radon and 0.0009 to 0.0036 Working Levels for radon daughters. The radon originates from natural radioactivity in the soil surrounding the homes. (author)

  9. Radon in public buildings; Radon in oeffentlichen Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, H.; Flesch, K. [IAF - Radiooekologie GmbH, Dresden (Germany); Hermann, E. [B.P.S. Engineering GmbH, Zwickau (Germany); Loebner, W. [Wismut GmbH, Chemnitz (Germany); Leissring, B. [Bergtechnisches Ingenieurbuero GEOPRAX, Chemnitz (Germany)

    2009-07-01

    From the Free State of Saxony, a study was commissioned to survey how reliable measurements to characterize the radon situation in public buildings at a reasonable financial and human effort can be carried out to reduce radiation exposure in public buildings. The study approach was for 6 objects. To characterize the radon situation the time evolution measurement of radon concentrations of more than 1 to 2 weeks turned out to be sufficient. A novel data analysis enables the identification of a ''typical daily alteration of the radon concentration'' depending on the ventilation conditions and the daily use of the offices or class rooms. The identification of typical diurnal radon variations for the working time and weekends or holidays is of fundamental importance for assessing the exposure situation in public buildings. It was shown that the radon concentration during working time are in general much lower than in the times when the buildings (offices) are unused. It turned out that the long-term radon measurements with nuclear track detectors within distinct time regimes (day / night, working hours / leisure time) by utilizing switch modules are very efficient to estimate the actual exposure. (orig.)

  10. Radon in Austria

    International Nuclear Information System (INIS)

    Friedmann, H.

    2000-01-01

    Several projects in Austria deal with the problem of enhanced radon exposure to the public. The Austrian Radon Project is the largest project within this task, with the aim of investigating the radon concentrations in Austrian homes. Another project concerns mitigation methods. According to the EU directive EURATOM 96/29 it is also necessary to check working places for possibly enhanced radon concentrations. These projects are and will be funded by the government. The federal government of Upper Austria sponsored a project to test the indoor air quality in kindergartens including radon measurements. Within an EU research project, the radon concentrations in Austrian springs and groundwater were systematically listed and analyzed. Additional investigations will focus on methods to improve the radon potential maps from the Austrian Radon Project by including geological and other information. (author)

  11. Measurements of indoor radon and radon progeny in Mexico City

    International Nuclear Information System (INIS)

    Cheng, Y.S.; Rodriguez, G.P.

    1996-01-01

    Indoor radon has been a public concern associated with increased lung cancer risks. Radon decay products interact with indoor aerosols to form progeny with different size distributions, which may influence the lung dosimetry when the progeny are inhaled. Air pollution in Mexico City is a serious problems with high particulate concentrations, but there are few reports of indoor radon measurement. The purposes of this study were to measure the aerosol concentration, radon concentration, and radon activity size distribution in the living area of three houses in Mexico City. The radon concentration was monitored by a RGM-3 radon gas monitor (Eberline, Inc., Santa Fe, NM). A graded diffusion battery was used to determine the progeny concentration and activity size distribution. The concentration and size distribution of the indoor aerosols were monitored by a quartz, crystal microbalance cascade impactor. Our measurements showed high concentrations of indoor aerosols (20-180 gg m -3 ). However, the radon concentrations-were low ( -1 ), but showed a clear diurnal pattern with peak concentrations from 2-10 AM. The activity size distributions of radon progeny were trimodal, with peaks of 0.6 nm, 4-5 nm, and 100 rim. Most activities were associated with large particle sizes. Our results indicated that indoor radon concentration was not high, due in part to a relatively high air exchange with outdoor air. The high aerosol concentration may also play an important part in the activity size distribution of radon progeny

  12. Radon and radon daughters in South African underground mines

    International Nuclear Information System (INIS)

    Rolle, R.

    1980-01-01

    Radon and the radon daughters are the radionuclides which primarily determine the level of the radiation hazard in underground uranium mines and to a smaller extent in non-uranium mines. Radon is a gas, and its daughters adsorb on aerosol particles which are of respirable size. The hazard thus arises from the alpha decay of radon and its daughters in contact with lung tissue. Radon is itself part of the uranium decay chain. The major radionuclide, 238 U, decays successively through thirteen shorter-lived radionuclides to 206 Pb. Radon is the only gaseous decay product at room temperature; the other twelve are solids. The main hazard presented by the uranium decay chain is normally determined by the radon concentration because gaseous transport can bring alpha emitters close to sensitive tissue. There is no such transport route for the other alpha emitters, and the level of beta and gamma radiation caused by the uranium decay chain generally presents a far lower external radiation hazard. Radon itself is the heaviest of the noble gases, which are He, Ne, Ar, Kr, Xe and Rn. Its chemical reactions are of no concern in regard to its potential hazard in mines as it may be considered inert. It does, however, have a solubility ten times higher than oxygen in water, and this can play a significant part in assisting the movement of the gas from the rock into airways. Radon continuously emanates into mine workings from uranium ores and from the uranium present at low concentrations in practically any rock. It has been found that the control of the exposure level is most effectively achieved by sound ventilation practices. In South African mines the standard of ventilation is generally high and exposure to radon and radon daughters is at acceptably low levels

  13. La metodologia de la valoracion contingente en la evaluacion de proyectos ambientales : el caso del saneamiento del Rio Medellin

    OpenAIRE

    Zuleta D., Fredy

    1994-01-01

    Como consecuencia del crecimiento de las ciudades, se hace cada vez más sentida la necesidad de desarrollar proyectos de carácter ambiental que subsanen el efecto negativo del urbanismo y las grandes concentraciones poblacionales. Tal es el caso de los rellenos sanitarios y sistemas de alcantarillado y tratamiento de aguas residuales, entre otros. Sin embargo, los problemas de contaminación y saneamiento, a pesar de sus consecuencias, no son los únicos que aquejan a la comunidad. Es un princi...

  14. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    International Nuclear Information System (INIS)

    Baumgartner, A.; Maringer, F.J.; Michai, P.; Kreuziger, M.

    2006-01-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  15. Efecto inhibidor del ácido jasmónico sobre el crecimiento de bacterias y hongos

    OpenAIRE

    Georgina Michelena; Giselle Almeida; Beatriz Altuna; Felipe Eng; Silvano Legrá; Maité Oliveros; Silvia Armenteros

    2005-01-01

    Se determinó el efecto de inhibición del AJ sobre el crecimiento del hongo Sclerotium rolfsii y de las bacterias Leuconostoc mesenteroides, Echerichia coli y Bacillus subtilis, con la técnica de envenenamiento de medio trabajando en placa Petri. Se obtuvieron inhibiciones del 70 % del S. rolfsii a concentraciones inferiores de AJ de 200 ppm y 100 % de inhibición del L. mesenteroides. Estos resultados mostraron la actividad antimicrobiana del AJ frente al hongo Sclerotium rolfsii, abriendo pos...

  16. Indoor radon

    International Nuclear Information System (INIS)

    1997-12-01

    The radon, a natural radioactive gas, is present almost everywhere on the earth's surface. It can be accumulated at high concentration in confined spaces (buildings, mines, etc). In the last decades many studies conducted in several countries showed that inhaling important amounts of radon rises the risk of lung cancer. Although, the radon is a naturally appearing radioactive source, it may be the subject of a human 'enhancement' of concentration. The increasing radon concentration in professional housing constitutes an example of enhanced natural radioactivity which can induce health risks on workers and public. Besides, the radon is present in the dwelling houses (the domestic radon). On 13 May 1996, the European Union Council issued the new EURATOM Instruction that establishes the basic standards of health protection of population and workers against the ionizing radiation hazards (Instruction 96/29/EURATOM, JOCE L-159 of 29 June 1996). This instruction does not apply to domestic radon but it is taken into consideration by another EURATOM document: the recommendation of the Commission 90/143/EURATOM of 21 February 1990 (JOCE L-80 of 27 March 1990). The present paper aims at establishing in accordance to European Union provisions the guidelines for radon risk management in working places, as well as in dwelling houses, where the implied risk is taken into account. This document does not deal with cases of high radon concentration on sites where fabrication, handling or storage of radium sources take place. These situations must be treated by special studies

  17. EFECTOS DEL MERCURIO SOBRE ALGUNAS PLANTAS ACUÁTICAS TROPICALES

    Directory of Open Access Journals (Sweden)

    Martha Isabel Posada

    Full Text Available El presente artículo es una descripción de los efectos del mercurio sobre algunas plantas acuáticas tropicales y sobre los ecosistemas donde habitan. Adicionalmente, se recomienda un protocolo para realizar pruebas de toxicidad con la lenteja de agua (Lemna minor y se presentan los resultados de los preensayos con diferentes concentraciones de sales de mercurio en condiciones de laboratorio. Se encontró que la biodisponibilidad del mercurio depende de factores que facilitan la disolución del elemento en el agua. Algunas plantas actúan como bioindicadores de la presencia de este metal en el medio al retenerlo selectivamente; mientras que otras se comportan como bioacumuladoras al tolerar su presencia y acumularlo en su estructura, y pueden dar paso a la bioconcentración a través de la cadena trófica. De acuerdo con los preensayos de toxicidad realizados con Lemna minor se sugiere que las concentraciones de sal de mercurio adecuadas para la realización de pruebas de toxicidad deben estar entre 0,01 mg/L y 10,0 mg/L.

  18. Radon reduction and radon-resistant construction demonstrations in New York state. Final report

    International Nuclear Information System (INIS)

    1991-02-01

    A survey of radon levels in New York State homes indicates that approximately 4.4 percent of the homes have long-term living area radon concentrations above the U.S. EPA guideline of four pCi/l. The project addressed the effectiveness of techniques to reduce the radon level in existing homes and to prevent the occurrence of high radon concentrations in new homes. The goal of the project was to demonstrate the effectiveness of radon reduction techniques in homes containing indoor radon concentrations of more than the current EPA guidelines of four pCi/l. At the same time, radon-resistant construction techniques were demonstrated in homes under construction to provide guidelines for houses being built in areas with a danger of high radon levels. The project demonstrated new radon mitigation techniques in homes containing indoor radon concentrations exceeding four pCi/l; assessed the value of previously installed radon reduction procedures, and demonstrated new radon-resistant construction methods

  19. Mechanisms of radon injury

    International Nuclear Information System (INIS)

    Cross, F.T.

    1988-01-01

    In this new project, they conduct molecular, cellular and whole-animal research relevant to understanding the inhalation toxicology of radon and radon-daughter exposures. The work specifically addresses the exposure-rate effect in radon-daughter carcinogenesis; the induction-promotion relationships associated with exposure to radon and cigarette-smoke mixtures; the role of oncogenes in radon-induced cancers; the effects of radon on DNA as well as on DNA repair processes; and the involvement of growth factors and their receptors in radon-induced carcinogenesis. Preliminary experiments showed that oncogenes are activated in radon-induced lung tumors. They have therefore begun further exposures pertinent to the oncogene and growth-factor studies. An in vitro radon cellular-exposure system was designed, and cell exposures were initiated. Initiation-promotion-initiation studies with radon and cigarette-smoke mixtures have also begun; and they are compiling a radon health-effects bibliography

  20. Evaluation of experiences in long-term radon and radon-daughter measurements

    International Nuclear Information System (INIS)

    Young, J.A.; Jackson, P.O.; Thomas, V.W.

    1982-12-01

    Pacific Northwest Laboratory (PNL) is performing side-by-side measurements of radon and radon daughter concentrations using several instruments and techniques, and is comparing these measurements with side-by-side measurements made by other investigators at other locations. The standard deviation of the differences between the (natural) logarithms of the Terradex Track Etch radon concentrations and the logarithms of the Radon Progency Integrating Sampling Units (RPISU) radon daughter concentrations (S.D.-ln) measured in 50 buildings in Edgemont, South Dakota, was 0.37. Using this S.D.-ln, it can be calculated that if the Track Etch radon daughter concentration is 0.010 WL there should be only a 14% probability that the RPISU average would be greater than 0.015 WL, and only a 3% probability tht the RPISU average would be greater than 0.020 WL. If buildings had been cleared from remedial action when the Track Etch averages were less than 0.10 WL, then about 61% of the buildings would have been cleared from remedial action, and only a few percent of these buildings would have actually had average RPISU concentrations greater than 0.015 WL. The S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements made by ALARA at Grand Junction, the PERM radon measurements and the MOD-225 radon daughter measurements made by Mound Facility at Canonsburg and Middlesex, and the PERM and Track Etch radon measurements made by Mound Facility at Salt Lake City were similar to the S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements at Edgemont

  1. Construction of radon/radon daughter calibraton chamber

    International Nuclear Information System (INIS)

    Fry, J.; Gan, T.H.; Leach, V.A.; Saddlier, J.; Solomon, S.B.; Tam, K.K.; Travis, E.; Wykes, P.

    1983-01-01

    The radon/radon daughter test chamber is a copper lined room 1.65x1.75x2.75m with an effective volume of 8000 litres. The air residence time is controlled by circulating the air in the chamber through absolute filters which remove 99.9% of particulates. Radon is drawn into the chamber from a 17 μCi 226 RaCl source using the pressure differential across the blowers (<3 psi)

  2. Application of single-chip microcomputer to portable radon and radon daughters monitor

    International Nuclear Information System (INIS)

    Meng Yecheng; Huang Zhanyun; She Chengye

    1992-01-01

    Application of single-chip microcomputer to portable radon and radon daughters monitor is introduced in this paper. With the single-chip microcomputer automation comes into effect in the process from sampling to measuring of radon and radon daughters. The concentrations of radon and radon daughters can be easily shown when the conversion coefficients are pre-settled before the measurement. Moreover, the principle and design are briefly discussed according to the characteristics of the monitor

  3. Compact detector for radon and radon daughter products

    International Nuclear Information System (INIS)

    Alter, H.W.; Oswald, R.A.

    1986-01-01

    This invention provides an improved compact track registration detector for radon gas. The detector comprises a housing having an open mouth, a bottom, and side walls; track registration means, supported inside the housing, which forms damage tracks along paths traversed by alpha particles; a microporous filter positioned across the mouth of the housing to prevent entry of radon daughters and particulate matter; and a cap that may be placed on the mouth of the housing to retain the filter. The housing has internal wall surfaces dimensioned to optimize the registration of alpha particles from radon and radon daughters present in the housing

  4. The use of soil gas as radon source in radon chambers

    International Nuclear Information System (INIS)

    Al-Azmi, Darwish

    2009-01-01

    A procedure is described in which soil gas is utilized as an alternative to the 226 Ra source for the supply of the radon gas required to fill a radon chamber where radon-measuring devices are calibrated. The procedure offers opportunities to vary the radon concentration within the chamber around an average value of about 500 Bq/m 3 , which is considered to be sufficient for calibrating indoor radon detectors. The procedure is simple and the radon source does not require radiation protection certification (for import and/or use), unlike the commercially produced standard radioactive ( 226 Ra) sources.

  5. Radon in Antarctica

    International Nuclear Information System (INIS)

    Ilic, R.; Rusov, V.D.; Pavlovych, V.N.; Vaschenko, V.M.; Hanzic, L.; Bondarchuk, Y.A.

    2005-01-01

    The paper reviews results of radon measurements obtained in Antarctic research stations in the last 40 years by both active and passive radon monitors. A brief description of the radon laboratory set-up in the Ukrainian Academician Vernadsky station on the Antarctic Peninsula (W 64 o 16 ' , S 65 o 15 ' ), where radon is measured by two types of etched track Rn dosimeter and 4 types of continuous radon monitoring devices is presented. Some selected results of research work are described related to: (i) analysis of radon storms, defined as an abrupt increase of 222 Rn during the occurrence of a cyclone, and its applicability for the study of the transport of air masses of continental origin to Antarctica; (ii) a study of the correlation of changes of radon concentration and geomagnetic field induced by tectonic activity and its application to predicting tectonomagnetic anomalies, and (iii) verification of a newly developed theoretical model based on noise analysis of the measured radon signal for earthquake prediction. Suggestions for future utilization of radon for basic research in Antarctica (and not only in Antarctica) conclude the contribution. conclude the contribution

  6. Radon-Instrumentation; Radon-Instrumentacion

    Energy Technology Data Exchange (ETDEWEB)

    Moreno y Moreno, A. [Departamento de Apoyo en Ciencias Aplicadas, Benemerita Universidad Autonoma de Puebla, 4 Sur 104, Centro Historico 72000 Puebla (Mexico)

    2003-07-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  7. Contaminación de las aguas del río Itaya por las actividades portuarias en el Puerto Masusa, Iquitos, Perú

    Directory of Open Access Journals (Sweden)

    Carmen Patricia Cerdeña

    2014-06-01

    Full Text Available Las actividades portuarias generan contaminación en las aguas y los alrededores del puerto. Los parámetros físico-químicos y microbiológicos permiten determinar la presencia o no de contaminación en los cuerpos de agua. La investigación tuvo como objetivo determinar la contaminación de las aguas del río Itaya por actividades portuarias del puerto Masusa - Iquitos. Se usó el diseño pre-experimental. Se encontró que existen diferencias significativas en los indicadores: pH, aceites y grasas, DBO5, DQO; y presencia de coliformes totales, coliformes termoreguladores y Escherichia coli. Se concluye que existe altas concentraciones de aceites y grasas en el puerto (63,45 mg/L en comparación con el río Amazonas (10 mg/L. El pH del agua del puerto (5,42 es ligeramente mayor al del río Amazonas (6,93. Los resultados muestran que el DQO del puerto Masusa (187mg/L es mayor a la DQO en el río Amazonas (50 mg/L. Las altas concentraciones de DBO5 en las aguas del puerto (87,5 mgO2 con respecto a las del río Amazonas (25 mgO2, nos permiten indicar que hay contaminación orgánica.  La presencia de concentraciones importantes de coliformes totales, coliformes termotolerantes y de Escherichia coli, indica que existe contaminación microbiológica. Dichos contaminantes se dan especialmente por desechos fecales vertidos directamente a las aguas.

  8. Contaminación de las aguas del río Itaya por las actividades portuarias en el Puerto Masusa, Iquitos, Perú

    Directory of Open Access Journals (Sweden)

    Carmen Patricia Cerdeña

    2014-07-01

    Full Text Available Las actividades portuarias generan contaminación en las aguas y los alrededores del puerto. Los parámetros físico-químicos y microbiológicos permiten determinar la presencia o no de contaminación en los cuerpos de agua. La investigación tuvo como objetivo determinar la contaminación de las aguas del río Itaya por actividades portuarias del puerto Masusa - Iquitos. Se usó el diseño pre-experimental. Se encontró que existen diferencias significativas en los indicadores: pH, aceites y grasas, DBO5, DQO; y presencia de coliformes totales, coliformes termoreguladores y Escherichia coli. Se concluye que existe altas concentraciones de aceites y grasas en el puerto (63,45 mg/L en comparación con el río Amazonas (10 mg/L. El pH del agua del puerto (5,42 es ligeramente mayor al del río Amazonas (6,93. Los resultados muestran que el DQO del puerto Masusa (187mg/L es mayor a la DQO en el río Amazonas (50 mg/L. Las altas concentraciones de DBO5 en las aguas del puerto (87,5 mgO2 con respecto a las del río Amazonas (25 mgO2, nos permiten indicar que hay contaminación orgánica.  La presencia de concentraciones importantes de coliformes totales, coliformes termotolerantes y de Escherichia coli, indica que existe contaminación microbiológica. Dichos contaminantes se dan especialmente por desechos fecales vertidos directamente a las aguas.

  9. Wind direction correlated measurements of radon and radon progeny in atmosphere: a method for radon source identification

    International Nuclear Information System (INIS)

    Akber, R.A.; Pfitzner, J.; Johnston, A.

    1994-01-01

    This paper describes the basic principles and methodology of a wind direction correlated measurement technique which is used to distinguish the mine-related and background components of radon and radon progeny concentrations in the vicinity of the ERA Ranger Uranium Mine. Simultaneous measurements of atmospheric radon and radon progeny concentrations and wind speed and direction were conducted using automatic sampling stations. The data were recorded as a time series of half hourly averages and grouped into sixteen 22.5 degrees wind sectors. The sampling interval and the wind sector width were chosen considering wind direction variability (σ θ ) over the sampling time interval. The data were then analysed for radon and radon progeny concentrations in each wind sector. Information about the wind frequency wind speed seasonal and diurnal variations in wind direction and radon concentrations was required for proper data analysis and interpretation of results. A comparison with model-based estimates for an identical time period shows agreement within about a factor of two between the two methods. 15 refs., 1 tab., 5 figs

  10. Changes in environmental radon related with the day eclipse; Cambios de radon ambiental relacionados con el eclipse del dia 11 de julio 1991

    Energy Technology Data Exchange (ETDEWEB)

    Gaso P, M I; Cervantes, M L; Segovia A, N; Espindola, V H

    1992-05-15

    Systematic studies of radon and of gamma dose in air in the Nuclear Center of Mexico during a period of nine months that include the total Sun eclipse happened at July 11, 1991 were carried out. The radon concentrations were measured with an electronic equipment that measures in continuous form and the rate of gamma dose in air was obtained with a ionization chamber. The results show that the radon fluctuations in air are influenced by the meteorological changes showing behaviors different to long and short term. The variations of long term are correlated directly with the external temperature while those of short term have an inverse relationship with the temperature. These last results are discussed regarding drastic atmospheric changes happened in the period and those light changes result of the total Sun eclipse. The rate of gamma dose in air showed stability during the study. (Author)

  11. Instruments to measure radon activity concentration or exposure to radon. Interlaboratory comparison 2011

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2011-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by BfS. A radon measuring service is recognized by the competent authority if it proves its organizational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the website www.bfs.de/de/ion/radon/fachinfomessung/vergleichspruefungen.html and from the European Information System on Proficiency Testing Schemes (eptis) available in the internet. (orig.)

  12. Uncertainties of estimating average radon and radon decay product concentrations in occupied houses

    International Nuclear Information System (INIS)

    Ronca-Battista, M.; Magno, P.; Windham, S.

    1986-01-01

    Radon and radon decay product measurements made in up to 68 Butte, Montana homes over a period of 18 months were used to estimate the uncertainty in estimating long-term average radon and radon decay product concentrations from a short-term measurement. This analysis was performed in support of the development of radon and radon decay product measurement protocols by the Environmental Protection Agency (EPA). The results of six measurement methods were analyzed: continuous radon and working level monitors, radon progeny integrating sampling units, alpha-track detectors, and grab radon and radon decay product techniques. Uncertainties were found to decrease with increasing sampling time and to be smaller when measurements were conducted during the winter months. In general, radon measurements had a smaller uncertainty than radon decay product measurements. As a result of this analysis, the EPA measurements protocols specify that all measurements be made under closed-house (winter) conditions, and that sampling times of at least a 24 hour period be used when the measurement will be the basis for a decision about remedial action or long-term health risks. 13 references, 3 tables

  13. Radon programme: presence and future

    International Nuclear Information System (INIS)

    Hulka, J.

    2009-01-01

    In this presentation an overview of radon programme experiences is presented. The paper summarises national radon policy, national programmes, legislation, the role of preventive measures and interventions with respect to existing and future exposure and knowledge of radon risk, problems of remediation strategies, practical protection in dwellings, radon measurements strategies, progress in radon measurement of an individual house (radon diagnosis), radon mapping process and sense of delineation of radon prone areas, natural radioactivity of building materials and radioactivity in public water and their role in the radon programme, public awareness on radon issue and publicity campaign. Some research activities are proposed aiming at effective solutions of radon issues in future

  14. Radon

    International Nuclear Information System (INIS)

    1990-01-01

    This leaflet in the At-a-Glance Series, describes what radon is, where it is found, why it presents a risk to health, the official advice, and the remedies that are available to reduce radon levels. (author)

  15. Total concentration and speciation of heavy metals in biosolids from urban origin; Concentracion total y especiacion de metales pesados en biosolidos de origen urbano origin

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Flores, Eduardo [Laboratorio de Ingenieria Ambiental, Instituto Tecnologico de Puebla, Puebla, Puebla (Mexico)]. E-mail: egonz1962@yahoo.com.mx; Tornero Campante, Mario Alberto [Colegio de Postgraduados - Campus Puebla, San Pedro Cholula, Puebla (Mexico); Angeles Cruz, Yolanda [Laboratorio de Ingenieria Ambiental, Instituto Tecnologico de Puebla, Puebla, Puebla (Mexico); Bonilla y Fernandez, Noemi [Departamento de Agroecologia y Ambiente, Instituto de Ciencias - Benemerita Universidad Autonoma de Puebla, Puebla, Puebla (Mexico)

    2009-02-15

    The analysis of heavy metals is a very important task to asses the potential environmental and health risk associated with biosolids deposition in agricultural soil. However, it is widely accepted that determination of total concentration of heavy metals does not give an accurate estimation of the potential environmental impact. So, it is necessary to apply speciation studies to obtain suitable information about their bioavailability. This study was carried out on sewage sludge samples collected in a municipal waste-water treatment plant, located in Puebla City (Mexico). They are used for amendment agricultural soil. The speciation of heavy metals (Cd, Cr, Cu, Ni, Pb and Zn) was made using a sequential extraction procedure. The aim was to determine their concentration in bioavailability fractions. It was got the total concentration of heavy metals using acid digestion in a closed system and was determined with atomic absorption spectrometry. The total concentrations of heavy metals were lower than that established by Mexican legislation. The heavy metals are mainly associated with the mineral fraction and organic matter and consequently they show low bioavailability. [Spanish] El analisis de metales pesados es una actividad importante cuando se quiere valorar el potencial riesgo ambiental y de salud asociado con la utilizacion de biosolidos en suelos agricolas. Sin embargo, es ampliamente aceptado que la determinacion del contenido total no da una valoracion apropiada del impacto ambiental causado. Por lo tanto, es necesario realizar estudios de especiacion para obtener informacion mas detallada sobre su biodisponibilidad. Este estudio se llevo a cabo con muestras de lodos residuales producidos en una planta de tratamiento de aguas residuales ubicada en la ciudad de Puebla (Mexico). Estos biosolidos son utilizados para enmendar suelos agricolas. La especiacion de metales pesados (Cd, Cr, Cu, Ni, Pb y Zn) se realizo usando un procedimiento de extraccion secuencial

  16. Relation between "terra rossa" from the Apulia aquifer of Italy and the radon content of groundwater: Experimental results and their applicability to radon occurrence in the aquifer

    Science.gov (United States)

    Tadolini, T.; Spizzico, M.

    The radon-222 (222Rn) activity in groundwater of the Apulian karstic aquifer in southern Italy is as great as 500 Becquerel per liter (Bq/L) locally. Normal radium-226 (226Ra) activity in the limestone and calcareous dolomites of the aquifer is not enough to explain such a high level. Laboratory investigations identified high 226Ra activity in the "terra rossa," the residuum occupying fissures and cavities in the bedrock, and also the relation between (1) 226Ra-bearing bedrock and "terra rossa" and (2) 222Rn in water. The "terra rossa" is the primary source of the radon in the groundwater. The experimental results show the need to characterize the "terra rossa" of Apulia on the basis of 226Ra activity and also to study the distribution and variations in 222Rn activity over time in the aquifer. Résumé L'activité du radon-222 (222Rn) dans les eaux souterraines de l'aquifère karstique des Pouilles, dans le sud de l'Italie, atteint localement 500 Becquerel par litre (Bq/L). L'activité normale du radium-226 (226Ra) dans les calcaires et dans les calcaires dolomitiques de l'aquifère n'est pas assez élevée pour expliquer des valeurs aussi élevées. Des analyses de laboratoire ont mis en évidence une forte activité en 226Ra dans la terra rossa, remplissage de fissures et de cavités de la roche, ainsi qu'une relation entre (1) la roche et la terra rossa contenant du 226Ra et (2) le 222Rn dans l'eau. La terra rossa est la source primaire de radon dans l'eau souterraine. Les résultats expérimentaux montrent qu'il est nécessaire de caractériser la terra rossa des Pouilles par son activité en 226Ra et d'étudier la distribution et les variations de l'activité en 222Rn au cours du temps dans l'aquifère. Resumen La actividad del radon-222 (222Rn) en el agua subterránea del acuífero cárstico de Apulia, al sur de Italia, alcanza localmente los 500Bq/L. La actividad normal del radio-226 (226Ra) en las calcitas y dolomitas del acuífero no es suficiente para

  17. Radon emanation from soils

    International Nuclear Information System (INIS)

    Markkanen, M.; Arvela, H.

    1992-01-01

    The results of gamma spectrometric sample measurements of radon ( 222 Rn) emanation coefficients and radium concentrations ( 226 Ra) from about 800 Finnish soil samples are presented. The radon emanation rate was measured in about 400 soil samples, using radon-tight cans and Lucas cells. The effects of water content and temperature on radon emanation were investigated, using various samples of different soil types. Radon emanation and the effect of water content on radon emanation were investigated separately for different grain sizes (samples of till). The results provide some information on radon emanation in different soil types and relate emanation in laboratory conditions to conditions in ground soil. In routine measurements of radon emanation from soil samples, use of a 5% water content was considered advisable. The correction coefficients of radon emanation varied between 0.3 and 1.5, depending on the water content and soil type. At 5% water content, hardly any difference was found between radon emanation at temperatures of 20 and 1 o C. Radon emanation was found to be an inverse function of grain sizes larger than 0.5 mm in diameter. (author)

  18. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, A. [Vienna Univ. of Technology, Atominstitut, Wien (Austria); Maringer, F.J.; Michai, P.; Kreuziger, M. [BEV-Federal Office of Metrology and Surveying, Wien (Austria)

    2006-07-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  19. Radon in geological medium

    Energy Technology Data Exchange (ETDEWEB)

    Hricko, J [GEOCOMPLEX, a.s., Bratislava (Slovakia)

    1996-12-31

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a{sub v} has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km{sup 2}. The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a{sub v} > 50 kBq/m{sup 3}). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs.

  20. Radon in geological medium

    International Nuclear Information System (INIS)

    Hricko, J.

    1995-01-01

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a v has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km 2 . The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a v > 50 kBq/m 3 ). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs

  1. Radiation exposure due to radon and radon daughters

    International Nuclear Information System (INIS)

    Ullmann, W.

    1976-01-01

    Underground miners working over long periods of time in mines with a high content of radon and radon daughters belong to that group of occupationally exposed persons who are subject to the greatest somatic risk, with values especially high if the permissible dose limits are exceeded. Follwing an overview of the permissible limits currently in use for radon and radon daughters as well as the results of examinations performed in nationally-owned underground mining of the G.D.R., considerations are presented on the measuring quantities requisite for statistical, control and safety measurements in this field. Finally, conclusions are drawn concerning the measuring procedures and instruments to be employed for practical work. (author)

  2. BGS Radon Protective Measures GIS

    International Nuclear Information System (INIS)

    Appleton, D.; Adlam, K.

    2000-01-01

    The British Geological Survey Radon Protective Measures Geographical Information System is described. The following issues are highlighted: Identification of development sites where radon protection is required in new dwellings; Mapping radon potential on the basis of house radon and geology; Radon Protective Measures GIS; Radon site reports; and Follow-up radon protective measures sire reports

  3. Radon Measurements in Vojvodina

    International Nuclear Information System (INIS)

    Bikit, I.; Bikit, K.; Forkapic, S.; Mrda, D.; Nikolov, J.; Todorovic, N.; Veskovic, M.

    2013-01-01

    Recent analyses of epidemiological studies of lung cancer risk from residential exposures demonstrate a statistically significant increase per unit of exposure below average annual concentrations of about 200 Bq/m 3 . Indoor radon measurements performed in Novi Sad in about 400 houses and flats are presented and discussed in this paper. By measuring gamma-activity of radon daughters, radon activity concentration was determined to be 50 Bq/m 3 . In Vojvodina region indoor radon levels were measured by alpha track detectors CR-39 on about 3000 locations during the winter seasons in the period of three years (2003-2005). The main aim of the present study was to explore the critical group of population for radon exposure and to estimate maximal annual doses. Existing radon maps which identify regions with elevated radon levels will improve data collection and analysis for the future radon campaigns. Collaboration on the JRC program of European indoor radon map and implementation of grid system are also discussed.(author)

  4. Radon and cancer

    International Nuclear Information System (INIS)

    2011-01-01

    This publication proposes an overview on what is known about the carcinogenic effect of radon. It recalls the origin of radon, its presence in the environment, and its radioactivity. It comments data on the relationship between exposure to radon and lung cancer, and with other forms of cancer. It discusses the role of the exposure level, and the cases of professional and domestic exposure with respect to these risks. It indicates the hazardous areas in France which are well identified, outlines that smokers are more likely victims of risks related to radon, that this risk is still underrated and underestimated (notably by the public). It gives an overview of existing regulations regarding exposure to radon, of public health policies and national plans concerning radon, and recalls some WHO recommendations

  5. Influencia del proceso de liofilización en la estabilidad microbiológica del yogur

    Directory of Open Access Journals (Sweden)

    Geânderson dos Santos

    2015-09-01

    Full Text Available El objetivo de este estudio fue evaluar la supervivencia de las bacterias ácido lácticas en el yogur antes, durante y después del proceso de liofilización con diferentes temperaturas de congelación y diferentes concentraciones de sacarosa. La elaboración del yogur tradicional y el liofilizado, fue con concentraciones de sacarosa de 0 % y 5,0 % y se emplearon temperaturas de 5, -25 y -80 ºC. El análisis y cálculo de bacterias ácido lácticas se realizó mediante la técnica de disolución en placa, utilizando medio de cultivo Agar Base M17 y Agar Lactobacillus MRS, a pH 5 ajustado con ácido acético, para determinación de Streptococcus thermophilus y Lactobacillus bulgaricus, respectivamente. Los resultados microbiológicos mostraron que la cantidad de UFC/g fue mayor que la requerida por la legislación durante y después de la etapa de procesamiento a las 2 temperaturas. No hubo efecto de la concentración de sacarosa en la protección o mantenimiento de la microflora del yogur. El yogur liofilizado y rehidratado elaborado en este trabajo, además de cumplir con la legislación, es también una opción para el mercado debido a la conservación por un período más largo. Se mantuvo a los microorganismos viables y en cantidad superior a 107UFC/g antes, durante y después del proceso de liofilización y rehidratación.

  6. Radon awareness in Ireland: a assessment of the effectiveness of radon road shows

    International Nuclear Information System (INIS)

    Synnott, H.

    2006-01-01

    Full text: In late 2004 the Radiological Protection Institute of Ireland (R.P.I.I.) initiated a series of radon road shows in areas designated as High Radon Areas 1 in the R.P.I.I. s national radon survey of homes. The main objective of these road shows was to provide information to a local audience on the risks of exposure to radon. These road shows target both employers and householders. Each road show has the same general format. A presentation and/or meeting with a major employer representative group within the area. The purpose is to make employers aware of the risks associated with exposure to radon in the workplace and to highlight their obligations under current Irish health and safety legislation regarding radon in the workplace. An information stand on radon manned by R.P.I.I. staff members in a local shopping centre or other similar area. This provides those concerned about radon with accessible information on radon exposure risks, how to measure radon and the steps a home owner could take to reduce radon concentrations where necessary. Where possible R.P.I.I. staff members visit one or more schools in the general area. A short presentation on radon was given to students and students were given an opportunity to asks questions Maximizing media exposure to publicize our visits is vital to the success of these visits. Each visit is preceded by a Press Release whose main aim is to brief local and national media on the radon issue so as to achieve maximum publicity mainly through radio and television coverage. In general the media are very interested in the whole radon area and R.P.I.I. staff members have given 57 radio and 10 television interviews to date since the commencement of this initiative. The four road shows carried out to date have been successful in encouraging householders to carry out radon measurements. Since the start of the road shows to the present, the R.P.I.I. has seen a 44% increase in the number of householders requesting radon

  7. Project Radon

    International Nuclear Information System (INIS)

    Ekholm, S.

    1988-01-01

    The project started in March 1987. The objective is to perform radon monitoring in 2000 dwellings occupied by people employed by State Power Board and to continue to contribute to the development of radon filters. The project participates in developing methods for radon measurement and decontamination and in adapting the methods to large scale application. About 400 so called radon trace measurements (coarse measurement) and about 10 action measurements (decontamination measurement) have been made so far. Experience shows that methods are fully applicable and that the decontamination measures recommended give perfectly satisfactory results. It is also established that most of the houses with high radon levels have poor ventilation Many of them suffer from moisture and mould problems. The work planned for 1988 and 1989 will in addition to measurements be directed towards improvement of the measuring methods. An activity catalogue will be prepared in cooperation with ventilation enterprises. (O.S.)

  8. Radon in the indoor of habitable and workable zones in the Estado de Mexico; Radon en el interior de zonas habitacionales y laborables del Estado de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Segovia, N.; Gaso, M.I.; Ponciano, G. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    The levels of the radon concentration and of suspended particles in the air of the indoor house-room and of laboratories, like part of a study related with the impact of the components of the tobacco smoke in the health of the active and passive smokers. The measures of the radon concentration were carried out with Honeywell A9000A systems and the fluctuations in the concentration and particle size they were determined with a Personal Measurer for the Data Acquisition of Particles in Real Time. The average value of the radon concentration inside the house-room was of 40 Bq m{sup -3}, observing frequently radon peaks superior to 148 Bq m{sup -3}. In the offices and laboratories, especially in those with little ventilation, the radon gas concentration showed superior values to the internationally established limits. The average value in 24 hours, of the particles (PM{sub 10}) inside the houses of smokers it was of 0. 751 {+-} 0.420 mg m{sup -3}, being reached concentrations so high as 1. 6 mg m{sup -3}, which is an order of superior magnitude to the maximum permissible limit of PM{sub 10} (0.150 mg m{sup -3}), settled down by the Mexican Legislation. (Author)

  9. EVALUACIÓN DEL BIOINSUMO DE FIQUE (Furcraea gigantea EN EL CONTROL DEL TIZÓN TARDÍO DE LA PAPA

    Directory of Open Access Journals (Sweden)

    DAVID EDUARDO ÁLVAREZ S

    2013-12-01

    Full Text Available Se evaluó el efecto de un bioinsumo elaborado a partir de jugo de fique (Furcraea gigantea Vent. en el manejo de la enfermedad del tizón tardío causada por el patógeno Phytophthora infestans en dos cultivos experimentales de papa (Solanum tuberosum L..e utilizóun diseño de bloques completos al azar con arreglo factorial, en donde el factor A correspondió a las concentraciones: 5, 10 y 15 L.ha-1 y el factor B al tiempo de fermentación: 2, 4 y 6 días (a 33ºCcomparados con un testigo absoluto (agua y un testigo comercial (Cymoxanil 8% + Mancozeb 64%.Los valores de severidad, incidencia y rendimiento determinaron que la aplicación de 15 L.ha-1 bajo un tiempo de fermentación de 4 días fue el único tratamiento que mostró diferencias estadísticas (P<0,05 con respecto al testigo absoluto pero con niveles de protección muy bajos.En un segundo ensayo se incrementaron las concentraciones evaluadas a20, 30 y 40 L.ha-1.Después de analizar estadísticamente los tratamientos se determinó que no existen diferencias significativas que sustenten la acción del extracto vegetal en la protección del cultivo.

  10. A Radon Chamber without Radium Source for Detector Calibration and Radon Measurements

    International Nuclear Information System (INIS)

    Al-Azmi, D.; Karunakara, N.

    2008-01-01

    A radon chamber of volume 216 liters was designed and constructed for calibration of radon detectors and radon test measurements. The main feature of this chamber is that the active 226 Ra source, to generate the 222 Rn inside the chamber volume, is not required. Instead, 222 Rn from soil gas is utilized for this purpose. The supply of radon comes from the soil gas. Soil gas is drawn from the soil to fill the chamber with high radon concentration levels (∼ 80 kBq/m3). Desired radon concentration levels can be obtained by drawing the soil gas for different time durations and/or flow rate (author)

  11. Radon reduction in waterworks

    International Nuclear Information System (INIS)

    Raff, O.; Haberer, K.; Wilken, R.D.; Funk, H.; Stueber, J.; Wanitschek, J.; Akkermann-Kubillus, A.; Stauder, S.

    2000-01-01

    The removal of radon from water using water aeration is one of the most effective methods for reducing radon in waterworks. Therefore, this report describes investigations on packed tower columns and shallow aeration devices and a method for mathematical modelling of gas exchange processes for dimensioning packed tower columns for radon removal. Moreover, possibilities for removing radon using active carbon filtration under waterworks typical conditions and for reducing indoor radon levels in waterworks are discussed. Finally, conclusions on the necessity of radon removal in German waterworks are drawn. (orig.) [de

  12. CONDICIONES DE CULTIVO DE LA PLANTA MATRIZ Y USO DEL ÁCIDO INDOLBUTÍRICO EN LA PROPAGACIÓN DEL MANDARINO ‘SUNKI’ BAJO ESTAQUILLA

    Directory of Open Access Journals (Sweden)

    ANDRÉS IVÁN PRATO SARMIENTO

    2016-01-01

    Full Text Available RESUMEN Los patrones se obtienen tradicionalmente en la citricultura a partir de semillas, seleccionándose las plantas de origen apomíctica. Sin embargo, hay riesgo de no realizarse la selección correcta, debido a la baja apomixis y la alta heterocigocidad en algunas especies o cultivares, como el mandarino ‘Sunki’. La obtención de los mismos por estaquillas solucionaría el problema. El objetivo de este trabajo fue evaluar el potencial de enraizamiento de estaquillas del mandarino ‘Sunki’ (Citrus sunki Hort. ex Tan., colectadas de matrices cultivadas en el campo o en ambiente protegido, utilizándose diferentes concentraciones del ácido indolbutírico (AIB. Las estaquillas se colectaron en el final de la primavera y se mantuvieron por 90 días en cámara de nebulización intermitente. Se adoptó el diseño experimental de bloques completos al azar, con cuatro repeticiones, en arreglo factorial 2 x 4, referente a dos condiciones de cultivo (matrices cultivadas en campo y en ambiente protegido y cuatro concentraciones del AIB (0, 750, 1.500 y 3.000 mg L-1. El enraizamiento del mandarino ‘Sunki’ fue elevado, alcanzando el 96% en las dos condiciones. La brotación (54% y la supervivencia (95% de las estacas presentaron valores satisfactorios, independientemente del AIB. El empleo del AIB solamente es necesario en estacas provenientes de plantas mantenidas en el ambiente protegido, puesto que mejora su enraizamiento y el número de raíces.

  13. Radon house doctor

    International Nuclear Information System (INIS)

    Nitschke, I.A.; Brennan, T.; Wadach, J.B.; O'Neil, R.

    1986-01-01

    The term house doctor may be generalized to include persons skilled in the use of instruments and procedures necessary to identify, diagnose, and correct indoor air quality problems as well as energy, infiltration, and structural problems in houses. A radon house doctor would then be a specialist in radon house problems. Valuable experience in the skills necessary to be developed by radon house doctors has recently been gained in an extensive radon monitoring and mitigation program in upstate New York sponsored by Niagara Mohawk Power Corporation and the New York State Energy Research and Development Authority. These skills, to be described in detail in this paper, include: (i) the use of appropriate instruments, (ii) the evaluation of the symptoms of a radon-sick house, (iii) the diagnostic procedures required to characterize radon sources in houses, (iv) the prescription procedures needed to specify treatment of the problem, (v) the supervision of the implementation of the treatment program, (vi) the check-up procedures required to insure the house cured of radon problems. 31 references, 3 tables

  14. Reasons for increasing radon concentrations in radon remediated houses

    International Nuclear Information System (INIS)

    Clavensjoe, B.

    1997-01-01

    The study comprises 31 single-dwelling houses where remedial actions were carried out in the 1980s. In all of them the radon concentrations have increased more than 30% according to recent control measurements. Radon sources are building material as well as the soil. The remedial actions dealt with ventilation systems, leakage through the basement floor, air cushions, sub-slab suction or radon wells according to the original problems. Causes for the increase varied: In many houses with soil radon problems, the installation of a normal mechanical ventilation system is not a good remedial action. In some houses on a ground with high permeability and high radon content in the soil air, the radon concentration may increase by the lowering of the indoor air pressure. In other houses the increase was a measurement effect, where sites/rooms were confused. Living related causes were identified in a number of cases, where fan speeds were reduced for energy conservation/noise reduction purposes or different use of windows airing had occurred. Extension of the dwelling space without changing the ventilation system caused the increase in one house. 23 refs

  15. The rediscovery of the sun; El redescubrimiento del sol

    Energy Technology Data Exchange (ETDEWEB)

    Arancibia, Camilo; Estrada A, Claudio [Centro de Investigacion en Energia (CIE) de la UNAM, Temixco, Morelos (Mexico)

    2010-07-01

    Over the past five years, a revolution has begun in the solar heat concentration. The installation of electricity generation plants based on solar concentration has started in several places in the world. But, things were not always like this; the history of the solar concentration elapsed during millennia at a much slower pace. So, to concentrate sunlight to obtain heat at high temperature has been a very attractive idea to scientists from different eras. It was during the second half of the 19th century and early 20th century that man began to work seriously on the use of concentrated solar power instead of coal, to operate thermal machines. Stands out, the work of Augustin Mouchot and his assistant Abel Pifre in France, who developed the first solar steam boiler, on the basis of a conical mirror that concentrated solar radiation in a cylindrical receiver located in the axis of the cone that acted as a boiler. This document describes various technologies to concentrate the solar radiation. Each of them has its niche application depending principally on the level of temperatures that makes it possible to achieve. [Spanish] En los ultimos cinco anos ha comenzado una revolucion en la concentracion solar. Se han comenzado a instalar plantas de produccion de electricidad basadas en concentracion solar en varios lugares del mundo. Pero, las cosas no siempre fueron asi; la historia de la concentracion solar transcurrio durante milenios a un paso mucho mas pausado. Asi, concentrar la luz solar para obtener calor a alta temperatura ha sido una idea muy atractiva para cientificos de diferentes epocas. Fue en la segunda mitad del siglo XIX y principios del XX que se comenzo a trabajar seriamente sobre la utilizacion de energia solar concentrada en lugar de carbon, para mover maquinas termicas. Destacan los trabajos de Augustin Mouchot y su ayudante Abel Pifre en Francia, quienes desarrollaron la primera caldera de vapor solar, basandose en un espejo conico que concentraba

  16. Indoor radon measurements and radon prognosis for the province of Kymi, southeastern Finland

    International Nuclear Information System (INIS)

    Pennanen, M.; Maekelaeinen, I.; Voutilainen, A.

    1996-12-01

    The purpose of the regional radon prognosis is to classify areas with different levels of radon risk. The radon prognosis gives the percentages of future homes expected to have indoor radon concentrations exceeding the levels of 200 and 400 Bq/m 3 . It is assumed that no protection against the entry of radon is used in construction. In this study about 5900 indoor radon measurements made in single family houses, semi-detached houses and row houses were used. Data on the location, geology and construction of buildings were determined from maps and questionnaires. An empirical statistical model, the adjusted indoor radon measurements and geological data were used to assess the radon risk from soil and bedrock in different areas. The building sites of the province of Kymi were divided into thirteen sub-areas. The radon prognosis are calculated for the most radon-prone foundation types including 1) houses with a slab-on-grade and 2) houses with a basement or hillside houses with open stairwells between basement and first floor. The radon levels are generally greater in the western part of the area. The radon risk is highest in gravel-dominated esker areas in southwestern, western (in Pyhtaa, Kotka, Anjalankoski, litti, Valkeala) and central (Taipalsaari) parts of the area. The radon risk is also high in some bedrock and till areas, also in southwestern and western parts of the area. In these areas the level of 200 Bq/m 3 will be exceeded in 80 % of new houses. About half of the future houses in these areas will have indoor radon concentrations exceeding 400 Bq/m 3 . The radon risk is lowest in the eastern part of the province of Kymi in every soil type. In this area the level of 200 Bq/m 3 will be exceeded in 30 % of new houses. Below 10 % will exceed 400 Bq/m 3 . (orig.) (14 refs.)

  17. Instruments to measure radon-222 activity concentration or exposure to radon-222. Intercomparison 2014

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2014-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by the Bundesamt fuer Strahlenschutz (BfS). A radon measuring service is recognized by the competent authority if it proves its organisational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the European Information System on Proficiency Testing Schemes (EPTIS) and from the BfS websites.

  18. Radon in workplaces

    International Nuclear Information System (INIS)

    Reichelt, A.; Lehmann, K.-H.; Reineking, A.; Porstendoerfer, J.; Schwedt, J.; Streil, T.

    2000-01-01

    The radiological assessment of the results of radon measurements in dwellings is not automatically applicable to workplaces due to different forms of utilization, constructional conditions, time of exposure, heating and ventilation conditions, additional aerosol sources, aerosol parameters, chemical substances, etc. In order to investigate the peculiarities of the radon situation in workplaces located inside buildings compared with that in dwellings, long-time recordings of radon, attached radon progeny and unattached radon progeny concentrations ( 218 Po, 214 Pb, 214 Bi) are carried out at several categories of workplaces (e.g. offices, social establishments, schools, production rooms, workshops, kitchens, agricultural facilities). 36 workplaces have been investigated. There have been carried out at least 2-3 long-time recordings for each workplace during different seasons. At the same time the gamma dose rate, meteorological conditions, aerosol particle concentrations have been registered. Many special dates from the workplaces and the buildings have been recorded. Activity size distribution of the aerosol-attached and unattached fraction of short-lived radon decay products have been determinated in 20 workplaces. Mainly the following measurement systems were used: Radon- and Radon Progeny Monitor EQF 3020, SARAD GmbH, Germany. Alpha-Track Radon Detectors, BfS Berlin, Germany. Screen Diffusion Batteries with Different Screens, University of Goettingen, Germany. Low-Pressure Cascade Impactor, Type BERNER. Condensation Nuclei Counter, General Electric, USA. PAEC-f p -Rn-Monitor, University of Goettingen, Germany. Through the measurements, many peculiarities in the course of the radon-concentration, the equilibrium factor F, the unattached fraction f p and the activity size distribution have been determined. These amounts are influenced mainly by the working conditions and the working intervals. The influence of these peculiarities in workplaces on the dose have

  19. Public perceptions of radon risk

    International Nuclear Information System (INIS)

    Mainous, A.G. III; Hagen, M.D.

    1993-01-01

    Since 1984, a significant amount of media attention has focused on health threats from radon gas exposure. Using a probability telephone survey of adults (n = 685), we studied public perceptions of risk from radon exposure versus other environmental health risks. The results indicated that 92% of those individuals who had heard of radon believe radon to be a health risk, although only 4% believe they are currently exposed to high levels of radon gas. Perception of risk from radon was positively related to other perceptions of environmental risks. Younger and less educated individuals were more likely to perceive radon as a health risk. Women were three-and-one-half times as likely as men to perceive risk from radon. However, there was no significant relationship between perceived risk from radon and cigarette smoking. Media attention has apparently led to public awareness of radon hazards, but further attention is needed to improve smokers' awareness of their special risks from radon

  20. Radon Research Program, FY 1991

    International Nuclear Information System (INIS)

    1992-03-01

    The scientific information being sought in this program encompasses research designed to determine radon availability and transport outdoors, modeling transport into and within buildings, physics and chemistry of radon and radon progeny, dose response relationships, lung cancer risk, and mechanisms of radon carcinogenesis. The main goal of the DOE/OHER Radon Research Program is to develop information to reduce these uncertainties and thereby provide an improved health risk estimate of exposure to radon and its progeny as well as to provide information useful in radon control strategies. Results generated under the Program were highlighted in a National Research Council report on radon dosimetry. The study concluded that the risk of radon exposure is 30% less in homes than in mines. This program summary of book describes the OHER FY-1991 Radon Research Program. It is the fifth in an annual series of program books designed to provide scientific and research information to the public and to other government agencies on the DOE Radon Research Program

  1. Swiss radon programme 'RAPROS'

    International Nuclear Information System (INIS)

    Zeller, W.

    1992-03-01

    The results of the five-year radon research program RAPROS presented in this report, allow for scientifically valid statements on the origin of elevated levels of indoor radon in Switzerland. These results form a basis for recommendations and for actions to be taken. Indoor radon concentrations have been measured in more than 4000 living-rooms and 2000 basements; a sampling density of about 0.2% of the Swiss housing stock. According to these measurements radon leads to an estimated average annual effective dose of 2 milli-Sievert, although in some regions the annual dose may be much higher. Extrapolation of the existing data shows that in about 10'000 Swiss houses radon may exceed 1000 Bq/m 3 . For these houses remedial actions are recommended. There seems to be no radon problem in the large cities in the Swiss Plateau. High indoor radon concentrations in Switzerland are due to the soil beneath the buildings. Data from the study indicated that the most important soil characteristic influencing indoor radon concentrations was its gas permeability. Because natural ventilation in a heated house creates a slight underpressure in the lower levels with respect to surrounding soils, radon is driven from the soil into the building. Weatherization of the houses to reduce energy consumption had in most cases no effect on the indoor radon concentrations. Radon from tap water or from building materials does not contribute significantly to indoor radon levels in Switzerland. The high levels in the Jura Mountains are thought to be associated with karstic limestone bedrock. Several houses within Switzerland have now been modified to reduce radon levels. The most successful mitigation technique combined forced-air ventilation with tightening of the basement to decrease or prevent air infiltration from the soil. (author) figs., tabs., refs

  2. Environmental radon

    International Nuclear Information System (INIS)

    Majumdar, S.K.; Schmalz, R.F.; Miller, E.W.

    1990-01-01

    This book covers many aspects of environmental radon, including: historical perspectives; occurrence and properties; detection, measurement, and mitigation, radon and health; and political, economic, and legislative impacts

  3. Radon thematic days - Conference proceedings

    International Nuclear Information System (INIS)

    2011-03-01

    This document brings together the available presentations given at the Radon thematic days organized by the French society of radiation protection (SFRP). Twenty five presentations (slides) are compiled in the document and deal with: 1 - General introduction about radon (Sebastien Baechler, IRA); 2 - Survey of epidemiological studies (Dominique Laurier, IRSN); 3 - Dosimetric model (Eric Blanchardon, Estelle Davesne, IRSN); 4 - Radon issue in Franche-Comte: measurement of the domestic exposure and evaluation of the associated health impact (Francois Clinard, InVS); 5 - WHO's (World Health Organization) viewpoint in limiting radon exposure in homes (Ferid Shannoun, OMS); 6 - Radon measurement techniques (Roselyne Ameon, IRSN); 7 - Quality of radon measurements (Francois Bochud, IRA); 8 - International recommendations (Jean-Francois Lecomte, IRSN); 9 - Radon management strategy in Switzerland - 1994-2014 (Christophe Murith, OFSP); 10 - 2011-2015 action plan for radon risk management (Jean-Luc Godet, Eric Dechaux, ASN); 11 - Radon at work place in Switzerland (Lisa Pedrazzi, SUVA); 12 - Strategies of radiation protection optimization in radon exposure situations (Cynthia Reaud, CEPN); 13 - Mapping of the radon potential of geologic formations in France (Geraldine Ielsch, IRSN); 14 - Radon database in Switzerland (Martha Gruson, OFSP); 15 - Radon 222 in taps water (Jeanne Loyen, IRSN); 16 - Buildings protection methods (Bernard Collignan, CSTB, Roselyne Ameon, IRSN); 17 - Preventive and sanitation measures in Switzerland (Claudio Valsangiacomo, SUPSI); 18 - Training and support approach for building specialists (Joelle Goyette-Pernot, Fribourg engineers and architects' school); 19 - Status of radon bulk activity measurements performed between 2005-2010 in public areas (Cyril Pineau, ASN); 20 - Neuchatel Canton experiments (Didier Racine, SENE); 21 - Montbeliard region experience in the radon risk management (Isabelle Netillard, Pays de Montbeliard Agglomeration); 22

  4. Radon in Estonian dwellings - Results from a National Radon Survey

    Energy Technology Data Exchange (ETDEWEB)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo [Estonian Radiation Protection Centre (Kiirguskeskus), Tallinn (Spain); Aakerblom, Gustav [Swedish Radiation Protection Authority, Stockholm (Sweden)

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m{sup 3}, in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m{sup 3}. In 1% of the dwellings the radon concentration exceeded 400 Bq/m{sup 3}. The highest radon concentration found in the study was 1040 Bq/m{sup 3}. Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m{sup 3}, and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m{sup 3}. The mean value for all Estonia dwellings is calculated

  5. Radon in Estonian dwellings - Results from a National Radon Survey

    International Nuclear Information System (INIS)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo; Aakerblom, Gustav

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m 3 , in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m 3 . In 1% of the dwellings the radon concentration exceeded 400 Bq/m 3 . The highest radon concentration found in the study was 1040 Bq/m 3 . Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m 3 , and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m 3 . The mean value for all Estonia dwellings is calculated to be 60 Bq/m 3 . Using

  6. Radon-film-badges by solid radiators to complement track detector-based radon monitors

    International Nuclear Information System (INIS)

    Tommasino, L.; Tommasino, M.C.; Viola, P.

    2009-01-01

    Existing passive radon monitors, based on track detectors, present many shortcomings, such as a limited response sensitivity for one-week-indoor measurements and a limited response linearity for the assessment of large radon exposures indoors, in thermal spa, in caves, and in soil. Moreover, for in-soil measurements these monitors are too bulky and are often conducive to wrong results. For what concerns the radon-in-water measurements, they are just not suitable. A new generation of passive radon monitors is introduced in this paper, which are very similar to the compact badges used in neutron- and gamma-dosimetry and will be referred to as radon-film-badges. These film-badges are formed by thin-film radiators with suitable radon-sorption characteristics, facing track detectors. The key strategy adopted for these radiators is to exploit an equilibrium type of radon sorption in solids. Even though this new generation of passive monitors is at its infancy, it appears already clear that said monitors make it finally possible to overcome most of the shortcomings of existing passive radon monitors. These devices are uniquely simple and can be easily acquired by any existing radon service to complement their presently used passive radon monitors with little or no effort.

  7. Radon in buildings

    International Nuclear Information System (INIS)

    Connell, J.J.

    1991-01-01

    This guide is intended to inform designers, householders and other building owners about the radon problem and to help in deciding if there is need to take any action to reduce radon levels in their homes or other buildings.It explains what radon is, how it enters buildings and what effect it may have on health. Reference is made to some of the usual ways of reducing the level of radon and guidance is given on some sources of assistance

  8. Calidad del aire en galpón avícola con ventilación natural durante la fase de pollitos

    Directory of Open Access Journals (Sweden)

    Robinson Osorio H.

    Full Text Available RESUMEN Los pollos de engorde durante la primera fase deben estar protegidos del estrés por frio, especialmente en el inverno, noches y madrugadas frías. Para proteger a los animales, los avicultores han utilizado diferentes estrategias, entre ellas está el uso de varias capas de cortinas para aumentar el nivel de aislamiento térmico y disminuir las pérdidas de calor, disminuyendo también la permeabilidad con el aire externo. En este contexto, es importante dar especial atención a la calidad del aire interno de los galpones avícolas como parte de una producción bajo parámetros de bienestar animal. El presente estudio fue realizado en el municipio de Barbacena, MG, en Brasil, y tuvo como objetivo evaluar la calidad del aire al nivel de los pollos y los trabajadores, específicamente de las concentraciones de amoniaco, dióxido de carbono y monóxido de carbono, en un galpón avícola naturalmente ventilado durante la primera fase de vida de pollos de engorde en el período de inverno, y la influencia del nivel de aislamiento con cortinas laterales sobre las concentraciones de amoniaco. Durante la primera semana experimental, los niveles de amoniaco sobrepasaron los valores aceptables, y se encontró diferencia estadística entre las concentraciones de amoniaco para los diferentes niveles de aislamiento con cortinas laterales.

  9. Radon and its hazards

    International Nuclear Information System (INIS)

    Chang Guilan

    2002-01-01

    The author describes basic physical and chemical properties of radon and the emanation, introduces methods of radon measurement, expounds the hazards of non-mine radon accumulation to the health of human being and the protection, as well as the history how the human being recognizes the hazards of radon through the specific data and examples, and finally proposes protecting measures to avoid the hazards of radon to the health of human being, and to do ecologic evaluation of environments

  10. PAPEL DE LOS HEMICANALES FORMADOS POR LA PANEXINA1 Y DEL ATP EXTRACELULAR DURANTE LA ADQUISICION DEL COMPROMISO MIOGENICO Y LA POTENCIACION DE LA CONTRACCION MUSCULAR ESQUELETICA ADULTA.

    OpenAIRE

    RIQUELME PEREZ, MANUEL ANTONIO; RIQUELME PEREZ, MANUEL ANTONIO

    2010-01-01

    En la ontogenia y estado adulto del músculo esquelético numerosas funciones 2+ dependen de incrementos de la concentracion intracelular de Ca 2- libre ([Ca ]'). Concordantemente, las células C 2C 12 de reserva (CR), modelo in vitro de células precursoras 110p.

  11. Radon reduction

    International Nuclear Information System (INIS)

    Hamilton, M.A.

    1990-01-01

    During a radon gas screening program, elevated levels of radon gas were detected in homes on Mackinac Island, Mich. Six homes on foundations with crawl spaces were selected for a research project aimed at reducing radon gas concentrations, which ranged from 12.9 to 82.3 pCi/l. Using isolation and ventilation techniques, and variations thereof, radon concentrations were reduced to less than 1 pCi/l. This paper reports that these reductions were achieved using 3.5 mil cross laminated or 10 mil high density polyethylene plastic as a barrier without sealing to the foundation or support piers, solid and/or perforated plastic pipe and mechanical fans. Wind turbines were found to be ineffective at reducing concentrations to acceptable levels. Homeowners themselves installed all materials

  12. Human perception of radon risk and radon mitigation: Some remarks

    International Nuclear Information System (INIS)

    Neznal, M.; Neznal, M.

    2008-01-01

    The Radon program in the Czech Republic has a relatively long and rich history. Procedures, which enable to evaluate the risk of radon penetration from the ground, to protect new buildings, to find existing buildings with elevated indoor radon levels and to realise remedial measures in such buildings, have been developed, published and tested. In some cases, the whole system may fail due to psychological or sociological reasons. Three types of problems (conflicts) will be presented: human behaviour affecting measurement results, conflict between individual and 'all-society' points of view, interpretation of radon risk itself. (authors)

  13. Radon/radon-daughter measurement methods and instrumentation

    International Nuclear Information System (INIS)

    Rock, R.L.

    1977-01-01

    Radon-daughter measurement equipment and techniques have been continuously improved over the last 25 years. Improvements have been in the areas of accuracy, time and convenience. We now have miniaturized scalers and detectors available for measuring the alpha particle count rates from aerosol samples collected on filter papers. We also have small lightweight efficient pumps for conveniently collecting samples and we have various counting methods which allow us to choose between making very precise measurements or nominal measurements. Radon-daughter measurement methods used in uranium mines and mills are discussed including a personal radon-daughter-exposure integrating device which can be worn by miners

  14. Radon level and radon effective dose rate determination in Moroccan dwellings using SSNTDs

    International Nuclear Information System (INIS)

    Oufni, L.; Misdaq, M.A.; Amrane, M.

    2005-01-01

    Inhalation of radon ( 222 Rn) and its daughter product are a major source of natural radiation exposure. The measurement of radon activity in dwelling is assuming ever increasing importance. It is known from recent surveys in many countries that radon and its progeny contribute significantly to total inhalation dose and it is fairly established that radon when inhaled in large quantity causes lung disorder. Keeping this in view, the indoor radon activity level and radon effective dose rate were carried out in the dwellings of Beni-Mellal, Khouribgra and Ben Guerir cities, Morocco, using the solid state nuclear track detectors (SSNTD) technique. Assuming an indoor occupancy factor of 0.8 and 0.4 for the equilibrium factor of radon indoors, we found that the 222 Rn effective dose rate in the studied dwellings ranges from 1.01 to 7.90mSvy -1 . The radon activity in the corresponding dwellings was found to vary from 40 to 532Bqm -3 . The radon activity has not only been found to vary with seasonal changes, but also with the age, the construction mode of houses, the ventilation conditions and with specific sites and geological materials

  15. EML indoor radon workshop, 1982

    International Nuclear Information System (INIS)

    George, A.C.; Lowder, W.; Fisenne, I.; Knutson, E.O.; Hinchliffe, L.

    1983-07-01

    A workshop on indoor radon, held at the Environmental Measurements Laboratory (EML) on November 30 and December 1, 1982, covered recent developments in radon daughter research and development. Thirty papers were presented dealing with standardization and quality assurance measurement methods, surveys, measurements strategy, physical mechanisms of radon and radon daughter transport and development of guidance standards for indoor exposures. The workshop concluded with a planning session that identified the following needs: (1) national and international intercomparisons of techniques for measuring radon and radon daughter concentrations, working level and radon exhalation flux density; (2) development and refinement of practical measurement techniques for thoron and its daughter products; (3) quantitative definition of the sources of indoor radon and the mechanisms of transport into structures; (4) better knowledge of the physical properties of radon daughters; (5) more complete and accurate data on the population exposure to radon, which can only be met by broadly based surveys; and (6) more international cooperation and information exchange among countries with major research programs

  16. Radon therapy; Radon in der Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Spruck, Kaija [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-04-01

    Radon therapies are used since more than 100 years in human medicine. Today this method is controversially discussed due to the possible increase of ionizing radiation induced tumor risk. Although the exact mode of biological radiation effect on the cell level is still not known new studies show the efficiency of the radon therapy without side effect for instance for rheumatic/inflammatory or respiratory disorders.

  17. Radon atlas of Finland

    International Nuclear Information System (INIS)

    Voutilainen, A.; Maekelaeinen, I.; Pennanen, M.; Reisbacka, H.; Castren, O.

    1997-11-01

    The most efficient means of reducing indoor radon exposure is to locate and mitigate dwellings with radon concentration exceeding the action level of 400 Bq/m 3 and to build new houses so that radon concentrations do not exceed 200 Bq/m 3 . The maps and tables in this report are useful tools for those who plan and decide what kind of radon mitigation measures are needed in municipalities. STUK (The Radiation and Nuclear Safety Authority) has an indoor radon database of 52 000 dwellings, for which the indoor radon concentration and construction details are known. The building site soil type of about 38 000 dwellings is known. This atlas is a summary of all indoor radon measurements made by STUK in lowrise dwellings and in first-floor flats. The results are shown as arithmetic means of 5- or 10-km squares on maps of the provinces. Three radon maps have been made for each province. On one map the data consist of all measurements the position coordinates of which are known. On the two other maps the building sites of houses are classified into permeable and low-permeable soil types. The tables show statistics for all indoor radon measurements by municipality and building site soil type. (orig.)

  18. Scopingreport radon

    International Nuclear Information System (INIS)

    Blaauboer, R.O.; Vaas, L.H.; Hesse, J.M.; Slooff, W.

    1989-09-01

    This report contains general information on radon concerning the existing standards, sources and emissions, the exposure levels and effect levels. lt serves as a basis for the discussion during the exploratory melting to be held in November/December 1989, aimed at determining the contents of the Integrated Criteria Document Radon. Attention is focussd on Rn-222 (radon) and Rn-220 (thoron), presently of public interest because of radon gas pollution in private homes. In the Netherlands air quality standards nor product standards for the exhalation rate of building materials have been recommended. The major source of radon in the Netherlands is the soil gas (> 97%), minor sources are phosphate residues and building materials (> 2% in total). Hence, the major concern is the transfer through the inhalation of air, the lung being the most critical organ at risk to develop cancer. Compared to risks for humans, the risks of radon and its daughters for aquatic and terrestric organisms, as well as for agricultural crops and livestock, are assumed to be limited. In the Netherlands the average dose for man due to radon and thoron progeny is appr. 1.2 mSv per year, the estimated dose range being 0.1-3.5 mSv per year. This dose contributes for about 50% to rhe total exposure due to all sources of ionizing radiation. Of this dose respectively 80% is caused by radon and about 90% is received indoor. The estimated dose for the general population corresponds to a risk for inducing fatal cancers of about 15 x 10-6 per year, ranging from 1.2 x 10-6 to 44 x 10-6 which exceeds the risk limit of 1 x 10-6 per year -as defined in the standardization policy in the Netherlands for a single source of ionizing radiation-with a factor 15 (1- 44). Reduction of exposure is only possible in the indoor environment. Several techniques have been described to reduce the indoor dose, resulting from exhalation of the soil and building materials. )aut- hor). 37 refs.; 3 figs.; 8 tabs

  19. Evaluación de la concentración de mercurio en arroz (Oryza sativa crudo y cocido procedente del municipio de San Marcos- Sucre y zona aurífera del municipio de Ayapel - Córdoba

    Directory of Open Access Journals (Sweden)

    Marcela P. Argumedo G.

    2015-08-01

    Full Text Available Introducción: Los metales se encuentran en todos los alimentos, siendo de mayor preocupación la presencia de metales tóxicos como el mercurio, debido a los efectos adversos que causa en la salud del hombre, lo que lo ha convertido en un grave problema de salud pública. Objetivo: Evaluar la concentración de mercurio en arroz (Oryza sativa crudo y cocido procedente del municipio de San Marcos - Sucre y zona aurífera del municipio de Ayapel - Córdoba. Metodología: El presente estudio es de tipo exploratorio y experimental. La toma de muestras fue realizada en tiempo de recolección del arroz (septiembre y se tomaron tres repeticiones de cada tipo o variedad de arroz (Fedearroz 2000 - LD 473. La cocción del alimento fue realizada en el laboratorio en condiciones similares a las utilizadas por habitantes de las comunidades donde fueron recolectadas las muestras. Para los análisis de relación estadística entre los tratamientos de cocción y la concentración de mercurio total en muestras, fue realizado un análisis de correlación simple. La determinación de diferencias estadísticamente significativas entre las muestras de arroz crudo y cocido fue realizada mediante un t-test y Anova. Resultados: Se presentaron concentraciones bajas de mercurio total y metilmercurio en las muestras de arroz crudo y cocido. Además, fue detectado que el proceso de cocción del alimento disminuye las concentraciones de HgT, en los diferentes tratamientos de tiempo de cocción. Conclusiones: Los habitantes de los municipios en estudio están expuestos a concentraciones mínimas de mercurio que podrían ser perjudiciales para su salud, debido a la alta ingesta de este cereal en la dieta de las comunidades.

  20. The effect of natural ventilation on radon and radon progeny levels in houses

    International Nuclear Information System (INIS)

    Cavallo, A.; Gadsby, K.; Reddy, T.A.; Socolow, R.

    1992-01-01

    In contradiction to the widely held assumption that ventilation is ineffective as a means of reducing indoor radon concentrations, experiments in a research house have shown that the basement radon level can be reduced by a factor of 5-10 using only natural ventilation. Measurements of the outdoor-basement pressure differential and the radon entry rate show that this unexpectedly large reduction in indoor radon levels is caused by two complementary physical processes. The first mechanism is the obvious one: dilution. Radon concentrations are lowered by the addition of uncontaminated outdoor air. The second mechanism is less evident: an open basement window reduces basement depressurisation. This decreases the rate at which radon-laden soil gas is drawn into the house. It was also found that the radon entry rate is a linear function of basement depressurisation up to a differential pressure of about 4 Pa, as would be expected for laminar soil gas flow; opening two basement windows approximately doubles the building air exchange rate and reduces the radon entry rate by up to a factor of 5. (author)

  1. Evaluación de diferentes concentraciones de etanol rectificado en la producción del “bioaroma” acetato de etilo y proteína unicelular por Candida utilis var. major C.E.C.T. 1430

    Directory of Open Access Journals (Sweden)

    Carlos León Torres

    2010-01-01

    Full Text Available El trabajo tuvo como objetivo evaluar diferentes concentraciones de etanol rectificado en la producción del “bioaroma” acetato de etilo y proteína unicelular por Candida utilis var.major . Se construyó un biorreactor de 16 cm de altura tipo tanque agitado con turbina Rushton. La preparación del inóculo fue realizada a partir de la cepa Candida utilis var.major C.E.C.T. 1430. El medio de cultivo fue formulado a partir de diluciones de etanol rectificado desde 10 hasta 35 g /L en intervalos de cada 5 unidades. El bioproceso se llevó a cabo a 25 ºC, pH de 4.5 – 5.5 y durante 60 horas. Se encontró que la biomasa y la productividad aumentan progresivamente, de 4.82 a 7.90 g/L y de 0.082 a 0.108 g/L - h respectivamente. Así mismo se determinó que a medida que aumenta la concentración (g/L de etanol rectificado, la producción y la productividad disminuyen. El rendimiento de acetato de etilo, fue máximo a la concentración de 15 g/L de etanol rectificado (5.7% y mínimo a 35 g/L y ( 1.97% respectivamente. Se concluye que el incremento de la concentración de etanol rectificado no influye aumentando la producción y rendimiento del “bioaroma” acetato de etilo y de la proteína unicelular de Candida utilis var. major .

  2. Radon og boligen

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    Radon er en radioaktiv og sundhedsskadelig luftart, som ved indånding øger risikoen for lungekræft. Der er ingen dokumenteret nedre grænse for, hvornår radon er ufarligt. Derfor anbefales det, at man tilstræber et så lavt radonindhold i indeluften som muligt. Man kan hverken lugte, se, høre eller...... smage radon, så vil du vide, om du har radon i din bolig, må du måle radonindholdet i indeluften. Radon forekommer naturligt i jorden og kan suges ind sammen med jordluft, hvis der inde er et undertryk, og hvis konstruktionerne mod jord er utætte. Jordluft trænger ind gennem revner og utætte samlinger......, fx omkring rør til kloak, vand og varmeforsyning. Koncentrationen af radon i jorden varierer meget fra sted til sted, også lokalt og gennem året. Tidligere undersøgelser har vist, at der kan forekomme høje koncentrationer i Sydgrønland, specielt i området syd for Narsalik ved Paamiut, 61°30’N....

  3. Radon campaigns. Status report 2008

    International Nuclear Information System (INIS)

    Arvela, H.; Valmari, T.; Reisbacka, H.; Niemelae, H.; Oinas, T.; Maekelaeinen, I.; Laitinen-Sorvari, R.

    2008-12-01

    Radon campaigns aim at activating citizens to make indoor radon measurements and remediation as well as increasing the common awareness of indoor radon questions. Indoor radon increases the risk of lung cancer. Through radon campaigns Radiation and Nuclear Safety Authority (STUK) also promotes the attainment of those goals that the Ministry of Social Affairs and Health has set for municipal authorities in Finland for prevention of the harmful effects of radon. The Ministry of Social Affairs and Health supports this campaign. Radon campaigns were started in autumn 2003. By autumn 2008 the campaigns have been organised already in 64 regions altogether in 160 municipalities. In some municipalities they have already arranged two campaigns. Altogether 14 100 houses have been measured and in 2 100 of these the action limit of radon remediation 400 Bq / m 3 has been exceeded. When participating in radon campaigns the house owners receive a special offer on radon detectors with a reduced price. In 2008 a new practice was introduced where the campaign advertisements were distributed by mail to low-rise residential houses in a certain region. The advertisement includes an order / deposit slip with postage paid that the house owner can send directly to STUK to easily make an order for radon measurement. In the previous radon campaigns in 2003 - 2007 the municipal authorities collected the orders from house owners and distributed later the radon detectors. The radon concentrations measured in the campaign regions have exceeded the action limit of 400 Bq / m 3 in 0 - 39% of houses, depending on the region. The total of 15% of all measurements made exceeded this limit. The remediation activities have been followed by sending a special questionnaire on remedies performed to the house owners. In 2006 - 2007 a questionnaire was sent to those households where the radon concentration of 400 Bq / m 3 was exceeded during the two first campaign seasons. Among the households that replied

  4. Radon and its daughters in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Rundo, J

    1984-05-01

    Prolonged exposure to radon should build up a reservoir of radon in body fat and fluids. Movement of the subject to an environment with a lower radon concentration from an environment with a higher level of radon would result in an exhalation of radon, and the initial exhalation rate of radon should depend on the radon concentration inhaled. This paper describes the behavior of radon and its daughters in vivo and a relationship between the radon exhalation rate and the time after a meal. A major but short-lived postprandial increase in the exhalation rate of radon was observed. We report a similar effect in the exhalation rate of radon by persons containing no radium. It should be noted that the possibility exists that a large amount of radon daughters in the chest may interfere in the investigation of possible internal contamination with plutonium or other actinides by external counting. (author).

  5. Radon in balneology - measurement of radon retention by patients and radiation protection for personell

    International Nuclear Information System (INIS)

    Just, G.; Falkenbach, A.; Grunewald, W.A.; Philipsborn, H. von

    2001-01-01

    In radon balneology patients are exposed to radon either from water or air through the skin or through inhalation. Drinking radon water was not included in the study. Previously, the radon transfer has been determined for an estimate of the medically active amount of radon retained in the patient. A simpler approach of measuring radon in expiration under and after exposure has now been standardised and applied to probands under different conditions of exposure. In addition, radon decay products were measured in sweat, saliva and in the skin. Experimental parameters were evaluated for a comparison of different concentrations observed under different conditions. Results are likely to improve both therapy for patients and radiation protection for members of the personnel. (orig.) [de

  6. Alteraciones del sueño, obesidad y resistencia a la insulina

    OpenAIRE

    Casanueva García de Alvear, María Asunción

    2016-01-01

    Numerosos parámetros metabólicos, desde niveles hormonales, a concentraciones de nutrientes en plasma, oscilan a lo largo del día en relación a los ciclos de luz-oscuridad, ingesta, y comportamiento. La regulación del metabolismo corporal (metabolismo lipídico, glucídico y proteico) y las hormonas que lo regulan, se correlaciona de una forma intensa con la relación establecida entre el sueño y la ritmicidad circadiana. Por tanto alteraciones del sueño conducirán a la disrupción de los proceso...

  7. Evaluación del efecto tóxico de extractos de Eupatorium microphyllum L.F. (Asteraceae) sobre larvas de Aedes aegypti (Diptera: Culicidae) en condiciones de laboratorio

    OpenAIRE

    Bello, Felio J.; Rozo, Álvaro; Zapata, Cristina

    2010-01-01

    En el presente trabajo se evaluó la actividad tóxica de extractos de Eupatorium microphyllum L.F. sobre larvas de IV estadio del mosquito Aedes aegypti (Linneaus), bajo condiciones de laboratorio. Se utilizaron extractos acuosos en concentraciones del 500 mg L-1, 1.500 mg L-1 y 2.500 mg L-1 y acetónicos en concentraciones de 10 mg L-1, 20 mg L-1, 30 mg L-1, 40 mg L-1 y 50 mg L-1. Los bioensayos se realizaron por triplicado, cada uno con 20 larvas, expuestas durante 24 horas a 150 mL de soluci...

  8. Radon Mapping of the Osijek Town

    International Nuclear Information System (INIS)

    Radolic, V.; Faj, Z.; Smit, G.; Culo, D.; Planinic, J.

    1998-01-01

    After ten years investigation of radon seasonal variations at three very different locations, as well as radon concentration measurements in kindergartens and schools, systematical indoor radon measurements were undertaken in dwellings of Osijek. Indoor radon was measured by means of the LR-115 nuclear track detector at 48 town locations that gave the arithmetic mean of 71.6 Bq m -3 , standard deviation of 44.0 Bq m -3 and geometric mean of 60.1 Bq m -3 , for the radon concentration range from 23 to 186 Bq m -3 . The empirical frequency distribution of radon concentrations, with the class width of 20 Bq m -3 , was in accordance with the theoretical log-normal distribution which was shown with χ 2 - test. The radon map pointed out a region of higher radon concentrations (central part of the town) that was ascribed to the geological soil structure. Thus supposition was confirmed by radon measurement in the soil gas using radon emanators with the LR-115 film that showed the positive correlation between radon concentrations in the soil and indoors. Radon measurements in Osijeks primary schools pointed out a school that had the highest radon concentration (300 Bq m -3 ) considering all the former indoor radon measurements. The radon distribution in the school building was investigated afterwards radon mitigation procedures were undertaken. (author)

  9. The effect and the amendment of thermoregulation to the stability of radon concentration in radon chamber

    International Nuclear Information System (INIS)

    Zhang Xiongjie; Wang Renbo; Qu Jinhui; Tang Bin; Zhu Zhifu; Man Zaigang

    2010-01-01

    When the temperature in the airtight radon chamber was adjusted, it would induce the frequent changes of the air pressure in chamber, then the radon concentration in the radon chamber would continuously reduce, which could seriously destroy the stability of the radon concentration in radon chamber. In this paper, on the study of the effect reasons to the stability of radon concentration in airtight radon chamber due to the thermoregulation, a new amendment scheme was put forward, and the solutions of the relevant parameters were discussed. The amendment scheme had been successfully applied to HD-6 radon chamber, and achieved good results. (authors)

  10. Application of a radon model to explain indoor radon levels in a Swedish house

    International Nuclear Information System (INIS)

    Font, LL.; Baixeras, C.; Joensson, G.; Enge, W.; Ghose, R.

    1999-01-01

    Radon entry from soil into indoor air and its accumulation indoors depends on several parameters, the values of which normally depend on the specific characteristics of the site. The effect of a specific parameter is often difficult to explain from the result of indoor radon measurements only. The adaptation of the RAGENA (RAdon Generation, ENtry and Accumulation indoors) model to a Swedish house to characterise indoor radon levels and the relative importance of the different radon sources and entry mechanisms is presented. The building is a single-zone house with a naturally-ventilated crawl space in one part and a concrete floor in another part, leading to different radon levels in the two parts of the building. The soil under the house is moraine, which is relatively permeable to radon gas. The house is naturally-ventilated. The mean indoor radon concentration values measured with nuclear track detectors in the crawl-space and concrete parts of the house are respectively 75±30 and 200±80 Bq m -3 . Results of the model adaptation to the house indicate that soil constitutes the most relevant radon source in both parts of the house. The radon concentration values predicted by the model indoors fall into the same range as the experimental results

  11. CONTRIBUTION OF RADON FLOWS AND RADON SOURCES TO THE RADON CONCENTRATION IN A DWELLING

    NARCIS (Netherlands)

    DEMEIJER, RJ; STOOP, P; PUT, LW

    1992-01-01

    In this paper a model is presented for analysis of the radon concentrations in a compartment in terms of contributions from transport by flows of air between compartments and from radon sources in the compartment. Measurements were made to study the effect of increased natural ventilation of the

  12. Radon and radon daughter monitoring (including thoron daughter monitoring)

    International Nuclear Information System (INIS)

    Leach, V.A.; Grealy, G.; Gan, W.

    1982-01-01

    Radon/radon daughter and thoron daughter measurement techniques are outlined. The necessary precautions and critical assessments of each method are also presented with a view to providing a better understanding of the various measurement methods

  13. Uranium prospecting through radon detection; La prospection de l'uranium par le radon

    Energy Technology Data Exchange (ETDEWEB)

    Pradel, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    Prospecting rests on the determination of the concentration of ground air in radon. Radon diffusing from deep uranium bearing layers is detected in upper ground layers. (author) [French] La prospection est basee sur l'etude de la concentration en radon dans l'air du sol. Dans les terrains superficiels, on decele le radon qui diffuse a partir des couches profondes uraniferes. (auteur)

  14. Certain problems about radon. Pt.1

    International Nuclear Information System (INIS)

    Wu Huishan

    2005-01-01

    Discussion has been made on certain pointed out problems which presently influence the work and development of radon survey, and certain specific problems have been put forward which should be paid much attention and taken measures. Among the problems, some come from cognition, i.e. two kinds of balance and examination about radon, chief culprit of radon's daughter, multiply control and migration, the significance of radon in the water and soil, important standards for designing and evaluating the sites of construction projects, thoughts on the mechanism of the harm of radon and its daughters, diseases causing of both high and low radon, difficulty of emanation of indoor radon, normal low radon from natural marble; and others must be resolved specifically, i.e. establishment of national radon standards as quickly as possible, improvement of on-the-spot examination technique, national-wide radon survey with multiple disciplines and technology, the research on the mechanism of radon's harm and the establishment national radon study center. (authors)

  15. Radon and its daughters in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Rundo, J

    1984-05-01

    Prolonged exposure to radon should build up a reservoir of radon in body fat and fluids. If the subject moved to an environment with a lower radon concentration from an environment with a higher level of radon, the result would be an exhalation of radon, and the initial exhalation rate of radon should depend of the radon concentration inhaled. This paper describes the behavior of radon and its daughters in vivo and a relationship between the radon exhalation rate and the time after a meal. A major but short-lived postprandial increase in the exhalation rate of radon was observed. The author reports a similar effect in the exhalation rate of radon by persons containing no radium. It should be noted that the possibility exists that a large amount of radon daughters in the chest may interfere in the investigation of possible internal contamination with plutonium or other actinides by external counting. 8 figures.

  16. Measurement of exhalation rate of radon and radon concentration in air using open vial method

    International Nuclear Information System (INIS)

    Horiuchi, Kimiko; Ishii, Tadashi.

    1991-01-01

    It was recognized that more than half of total exposure dose on human subject is caused by radon and its decay products which originate from naturally occurring radioactive substances (1988 UNSCEAR). Since then the exhalation of radon from the ground surface has received increasing attention. The authors have developed a new method for the determination of radon in natural water using toluene extraction of radon and applying a liquid scintillation counter of an integral counting technique which is able to get the absolute counting of radon. During these studies, the authors found out that when a counting vial containing of Liquid scintillator (LS)-toluene solution, without a lid, is exposed to the atmosphere for a while, dissolution of radon clearly occurs due to high solubility of radon into toluene layer. To extend this finding for the determination of radon in the atmosphere, the authors devised a new method to actively collect the atmosphere containing radon in a glass bottle by discharging a definite amount of water in it, which is named as open-vial dynamic method. The radon concentration can be easily calculated after the necessary corrections such as the partition coefficient and others. Applying proposed method to measure the radon exhalation rate from the ground surface and radon concentration in air of the dwelling environment, radioactive mineral spring zone and various geological formation such as granitic or sedimentary rocks. (author)

  17. CALIDAD DEL AIRE EN EL VALLE DE ABURRÁ ANTIOQUIA -COLOMBIA

    Directory of Open Access Journals (Sweden)

    JULIAN BEDOYA

    2009-01-01

    Full Text Available Medellín y otros 9 municipios vecinos conforman un área metrópolitana densamente poblada concentrada en un hábitat geográficamente estrecho y poco ventilado. Las múltiples actividades industriales y de transporte que se realizan en la ciudad arrojan a la atmósfera cantidades de contaminantes que podrían estar afectando desfavorablemente la calidad del aire que respiran sus habitantes. Analizar la calidad del aire en Medellín y su área metropolitana período 2001-07.. Se explora el comportamiento de los contaminantes atmosféricos en el área Metropolitana del valle de Aburrá, con base en los datos primarios recolectados por la Red de Monitoreo de la Calidad del Aire. Se confirma la información con mediciones actualizadas realizadas con rigor de precisión y reproducibilidad para garantizar la calidad y consistencia de los datos. Las concentraciones de partículas en suspensión total (PST y de partículas respirables (PM10 se encuentran elevadas a niveles que exceden en 200- 400% los límites de precaución definidos por la Organización Mundial de la Salud y la tendencia es al empeoramiento a medida que crece la densidad vehicular. También hay presencia de otros gases contaminantes en concentraciones menores. La contaminación del aire por material particulado en Medellín y su área metropolitana es alta, y ha de estar generando consecuencias indeseables en la salud de sus habitantes.

  18. Risks from radon

    International Nuclear Information System (INIS)

    Doll, Richard

    1992-01-01

    The best estimate of risk to which everyone is exposed from natural radon in buildings is now obtained by extrapolation from observations on men exposed to radon in mines. The relationship between dose and effect derived by the US National Research Council implies that about 6% of the current life-time risk of developing the disease in the UK is attributable to radon, but for residents of some houses it will be much greater. This estimate is dependent on many assumptions, some of which are certainly wrong, and reliable estimates can be obtained only by direct observations on people living in different houses. It is possible that radon may also cause some risk of other cancers, notably leukaemia, but such risks, if real, are certainly small. Studies in progress should provide reliable estimates of all radon induced risks within a few years. (author)

  19. Radon: Detection and treatment

    International Nuclear Information System (INIS)

    Loken, S.; Loken, T.

    1989-01-01

    Within the last few years, natural radon exposure in non-industrial settings, primarily homes, has become a health concern. Research has demonstrated that many homes throughout the United States have radon concentrations much higher than the legal federal limits set for miners. Thousands of unsuspecting people are being exposed to high levels of radiation. It is estimated that up to 15 percent of lung cancers are caused from radon. This is a significant health risk. With basic knowledge of the current information on radon, a primary health care provider can address patients' radon concerns and make appropriate referrals

  20. Managing Radon in Schools

    Science.gov (United States)

    EPA recommends testing all schools for radon. As part of an effective IAQ management program, schools can take simple steps to test for radon and reduce risks to occupants if high radon levels are found.

  1. Radon in workplaces

    International Nuclear Information System (INIS)

    Gooding, Tracy

    1995-01-01

    The naturally occurring radioactive gas radon has been found at excessive levels in many workplaces other than mines throughout the country. Prolonged exposure to radon and its decay products increases the risk of developing lung cancer, and controls to protect employees from excessive exposure are included in the Ionising Radiations Regulations 1985. The control of occupational exposure to radon is discussed here. (author)

  2. Efectos del enriquecimiento con N y P sobre la comunidad del fitoplancton en microcosmos de un embalse tropical (La Mariposa, Venezuela

    Directory of Open Access Journals (Sweden)

    Ernesto J. González

    1998-03-01

    Full Text Available Para evaluar el efecto del enriquecimiento con nutrientes sobre la comunidad del fitoplancton del embalse La Mariposa (Venezuela, se establecieron microcosmos "in situ" durante 6 días. Los microcosmos consistieron en bolsas de polietileno con 10 l de agua epilimnética filtrada del embalse, sometidos a diferentes combinaciones de enriquecimiento con fósforo y nitrógeno, para así simular un proceso de eutroficación. Se determinaron las concentraciones de clorofila 'a', la concentración de nitrógeno total y fósforo total y la proporción numérica de los diferentes grupos del fitoplancton. Como consecuencia del enriquecimiento de nutrientes, se produjo un aumento en la biomasa del fitoplancton, siendo las respuestas más pronunciadas en los tratamientos donde ambos nutrientes estaban presentes. Los grupos Cryptophyta, Euglenophyta y Pyrrophyta desaparecieron de los microcosmos fertilizados al finalizar el período de estudio, mientras que las Chlorophyta y las Cyanobacteria aumentaron sus proporciones relativas. Las diatomeas disminuyeron su proporción relativa a altas concentraciones de nitrógeno. Aunque la técnica del microcosmos tiene limitaciones en su significado ecológico, permite obtener una valiosa aproximación para entender lo que ocurre en las situaciones naturales.The effect of nutrient enrichment (N and P on the phytoplankton community of La Mariposa reservoir (Venezuela was studied. Polyethylene bags (microcosms were filled with 10 l of filtered epilimnetic water of the reservoir, and enriched with different nutrient proportions, simulating an eutrophication process. Chlorophyll 'a', total nitrogen, total phosphorus, and phytoplankton abundance were determined. There was an increase in phytoplankton abundance because of nutrient enrichment, specially when both nutrients were present. After the experiments, Cryptophyta, Euglenophyta, and Pyrrophyta dissappeared from the microcosms, whereas Chlorophyta and Cyanobacteria

  3. Radon and radon daughter measurements at and near the former Middlesex Sampling Plant, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    Haywood, F.F.; Perdue, P.T.; Christian, D.J.; Leggett, R.W.; Dickson, H.W.; Myrick, T.E.

    1980-03-01

    The results of the radon and radon daughter measurements made to date (1978) at the Middlesex Sampling Plant in Middlesex, New Jersey, are presented in this report. These measurements were one portion of a more comprehensive radiological survey conducted at this site and the surrounding area from 1976 to 1978. The surveyed property served as a uranium ore sampling plant during the 1940's and early 1950's and as a result contains elevated levels of surface an subsurface contamination. On-site indoor radon daughter and radon concentrations exceeded both the US Surgeon General Guidelines and the Nuclear Regulatory Commission's maximum permissible concentration limits for radon (10 CFR Part 20) in all structures surveyed. Off-site structures showed concentrations of radon and radon daughters at or only slightly above background levels, except for one site where the radon levels were found to be above the 10 CFR Part 20 guidelines. Outdoor radon ad radon daughter concentrations, measured both on and off the site, were well below the guidelines, and the data give no indication of significant radon transport from the site

  4. Geographical associations between radon and cancer: is domestic radon level a marker of socioeconomic status?

    International Nuclear Information System (INIS)

    Wolff, S.P.; Stern, G.

    1991-01-01

    Previous studies showing a geographical association between radon and various cancers, particularly the leukaemias and lymphomas, appear to be confounded by the role of radon levels as a surrogate for socioeconomic status. Higher socioeconomic status (at least at the UK county level) is correlated with higher levels of domestic radon. Controlling for the relationship between socioeconomic status and radon removes the correlation between radon exposure and lymphoproliferative disease. Reported associations between radon and lymphoproliferative disease (and possibly other cancers) may be secondary to socioeconomic variables. (author)

  5. Inverse method for determining radon diffusion coefficient and free radon production rate of fragmented uranium ore

    International Nuclear Information System (INIS)

    Ye, Yong-jun; Wang, Li-heng; Ding, De-xin; Zhao, Ya-li; Fan, Nan-bin

    2014-01-01

    The radon diffusion coefficient and the free radon production rate are important parameters for describing radon migration in the fragmented uranium ore. In order to determine the two parameters, the pure diffusion migration equation for radon was firstly established and its analytic solution with the two parameters to be determined was derived. Then, a self manufactured experimental column was used to simulate the pure diffusion of the radon, the improved scintillation cell method was used to measure the pore radon concentrations at different depths of the column loaded with the fragmented uranium ore, and the nonlinear least square algorithm was used to inversely determine the radon diffusion coefficient and the free radon production rate. Finally, the solution with the two inversely determined parameters was used to predict the pore radon concentrations at some depths of the column, and the predicted results were compared with the measured results. The results show that the predicted results are in good agreement with the measured results and the numerical inverse method is applicable to the determination of the radon diffusion coefficient and the free radon production rate for the fragmented uranium ore. - Highlights: • Inverse method for determining two transport parameters of radon is proposed. • A self-made experimental apparatus is used to simulate radon diffusion process. • Sampling volume and position for measuring radon concentration are optimized. • The inverse results of an experimental sample are verified

  6. Radon exhalation rates corrected for leakage and back diffusion – Evaluation of radon chambers and radon sources with application to ceramic tile

    Directory of Open Access Journals (Sweden)

    M. Abo-Elmagd

    2014-10-01

    Full Text Available The natural radon decay, leakage and back diffusion are the main removal processes of radon from its container. Ignoring these processes leads to underestimate the measured value of radon related parameters like exhalation rate and radium content. This work is aimed to evaluate two different radon chambers through determining their leakage rate λv and evaluation of radon source by determine its back diffusion rate λb inside the evaluated radon chambers as well as a small sealed cup. Two different methods are adapted for measuring both the leakage rate and the back diffusion rate. The leakage rate can be determined from the initial slope of the radon decay curve or from the exponential fitting of the whole decay curve. This can be achieved if a continuous monitoring of radon concentration inside the chamber is available. Also, the back diffusion rate is measured by sealing the radon source in the chamber and used the initial slope of the buildup curve to determine λb and therefore the exhalation rate of the source. This method was compared with simple equation for λb based on the ratio of the source to the chamber volume. The obtained results are applied to ceramic tile as an important radon source in homes. The measurement is targeted the ceramic glaze before and after firing as well as the obtained tile after adhere the glaze on the tile main body. Also, six different tile brands from Egyptian market are subjected to the study for comparison.

  7. Mercurio en tiburón Sphyrna lewini y Carcharhinus falciformis del pacífico guatemalteco

    Directory of Open Access Journals (Sweden)

    Eduardo E. Chacón

    2017-03-01

    Full Text Available El objetivo del estudio fue determinar la presencia de mercurio en muestras de carne de dos especies de tiburón: Sphyrna lewini y Carcharhinus falciformis, acopiados por la pesca artesanal en dos puntos de la costa pacífica de Guatemala. Con el análisis de la información se verificó el estado de inocuidad de los organismos respecto a las concentraciones de mercurio, utilizando como base la normativa europea. Se recolectaron 66 muestras, durante 10 meses, las cuales fueron analizadas utilizando la técnica de espectrofotometría de absorción atómica. Posteriormente se realizó un análisis descriptivo y se aplicó la ecuación del Índice de Peligro Sistémico (IP. El análisis de resultados indicó que 16 (73% organismos de S. lewini, presentaron concentraciones de mercurio superiores al límite máximo permisible (LMP de acuerdo a la normativa europea (1 mg/kg de peso fresco, aunque el IP (1.626857143 x 10 -4 demostró que no existe riesgo potencial para la salud de los consumidores, además que esta especie no muestra correlación significativa (ρ = 0.292, entre el tamaño del organismos y la concentración de mercurio. Únicamente 4 (9% organismos de la especie C. falciformis, presentaron concentraciones de mercurio arriba del límite máximo permisible de acuerdo a la normativa europea, y el cálculo de IP (4.345714286 x 10 -5 , indicó que el músculo de dicha especie puede consumirse sin ningún riesgo potencial para las personas.

  8. La metodología de valoración contingente en la evaluación de proyectos ambientales: el caso del saneamiento del río Medellín

    OpenAIRE

    Freddy Zuleta D

    1994-01-01

    Como consecuencia del crecimiento de las ciudades, se hace cada vez más sentida la necesidad de desarrollar proyectos de carácter ambiental que subsanen el efecto negativo del urbanismo y las grandes concentraciones poblacionales, Tal es el caso de los rellenos sanitarios y sistemas de alcantarillado y tratamiento de aguas residuales, entre otros. Sin embargo, los problemas de contaminación y saneamiento, a pesar de sus consecuencias, no son los únicos que aquejan a la comunidad. Es un princi...

  9. Studies of Radon and Radon Progeny in Air Conditioned Rooms in Hospitals

    International Nuclear Information System (INIS)

    Marley, F.; Denman, A.R.; Phillips, P.S.

    1998-01-01

    A series of continuous real-time radon and radon progeny measurements together with passive etched track detector measurements were performed in hospital premises during 1996. In one small room, detailed measurements over several weeks showed that both the radon concentration and the Equilibrium Factor depended on the intermittent operation of a filtered positive pressure displacement air-conditioning system, which was designed to conform to operating theatre standards. The average radon level measured while the air-conditioning was off was almost four times higher than that recorded whilst it was on. The progeny level was over five times higher than that whilst it was on. Thus, the Equilibrium Factor (F), was significantly lower when the air-conditioning was on. Measurements in similar rooms in two hospitals, confirmed that the reduction in radon level was a general finding. Thus staff working in such environments receive significantly lower radiation dose from radon than staff working in nearby normally ventilated rooms. (author)

  10. A comparison of contemporary and retrospective radon gas measurements in high radon dwellings in Ireland

    International Nuclear Information System (INIS)

    Kelleher, K.; McLaughlin, J.P.; Fenton, D.; Colgan, P.A.

    2006-01-01

    Little correlations has been found between contemporary radon gas measurements made in the past and retrospective radon gas measurements in Irish dwellings. This would suggest that these two techniques would result in two significantly different cumulative radon exposure estimates. Contemporary radon gas measurements made a few years apart in the same room of a dwelling were found to be significantly different. None of these differences could be explained by known changes to the rooms themselves., such ventilation or structural alterations to the room. This highlights the limitations of the contemporary radon gas measurements as a surrogate measurement for use in residential radon epidemiology. The contemporary radon gas measurements made by the Radiological Protection Institute of Ireland (R.P.I.I.) and University College of Dublin (U.C.D.) do not cover the same exposure period as the retrospective estimates and so the accuracy of the retrospective measurements cannot be demonstrated. A weak correlation can be seen between the retrospective radon gas estimates and a combination of the two contemporary radon gas estimates. It is not unreasonable to expect improvement in the correlation if further contemporary radon gas measurements were made in these rooms. (N.C.)

  11. Radon in workplaces

    International Nuclear Information System (INIS)

    Markkanen, M.; Annanmaeki, M.; Oksanen, E.

    2000-01-01

    The EU Member States have to implement the new Basic Safety Standards Directive (BSS) by May 2000. The Title VII of the Directive applies in particular to radon in workplaces. The Member States are required to identify workplaces which may be of concern, to set up appropriate means for monitoring radon exposures in the identified workplaces and, as necessary, to apply all or part of the system of radiological protection for practices or interventions. The BSS provisions on natural radiation are based on the ICRP 1990 recommendations. These recommendations were considered in the Finnish radiation legislation already in 1992, which resulted in establishing controls on radon in all types of workplaces. In this paper issues are discussed on the practical implementation of the BSS concerning occupational exposures to radon basing on the Finnish experiences in monitoring radon in workplaces during the past seven years. (orig.) [de

  12. Radon Research Program, FY 1992

    International Nuclear Information System (INIS)

    1993-04-01

    The United States Department of Energy, Office of Health and Environmental Research (DOE/OHER) is the principal federal agency conducting basic research related to indoor radon. The scientific information being sought in this program encompasses research designed to determine radon availability and transport outdoors, modeling transport into and within buildings, physics and chemistry of radon and radon progeny, dose response relationships, lung cancer risk, and mechanisms of radon carcinogenesis. There still remains a significant number of uncertainties in the currently available knowledge that is used to estimate lung cancer risk from exposure to environmental levels of radon and its progeny. The main goal of the DOE/OHER Radon Research Program is to develop information to reduce these uncertainties and thereby provide an improved health risk estimate of exposure to radon and its progeny and to identify and understand biological mechanisms of lung cancer development and required copollutants at low levels of exposure. Information useful in radon control strategies is also provided by the basic science undertaken in this program

  13. Modeling of indoor radon

    International Nuclear Information System (INIS)

    Paschoa, A.S.

    1990-01-01

    This paper reports on models for radon, which are developed not only to describe the behavior of radon and daughters since the moment that radon is created in natural sources by the alpha decay of 226 Ra up to the point that doses to humans are estimated based on the inhalation of radon and its progeny. The objective of a model should be determinant in defining the model structure and boundaries. Modeling indoors radon is particularly useful when the 226 Ra concentration in building materials and soils can be known before a house will be built with such 226 Ra bearing materials and over 226 Ra rich soils. The reported concentrations of 226 Ra in building materials range from 0.3 Bq · kg -1 in wood to about 2.6 x 10 3 Bq · kg -1 in aerated concrete based on alum shale. 30 In addition, when a house is built on a soil containing a high 226 Ra concentration, radon exhalation from the soil contributes to increase radon concentration indoors. The reported radon exhalation from soils range from 3.4 Bq · m -2 · s -1 in latosolic soil from Osaka, Japan to about 53 mBq · m -2 · s -1 in chernozemic soil from Illinois

  14. Scopingsreport Radon

    NARCIS (Netherlands)

    Blaauboer RO; Vaas LH; Hesse JM; Slooff W

    1989-01-01

    Dit scopingsrapport vormt een onderdeel van de voorbereiding tot het opstellen van het basisdocument radon. Het doel van dit rapport is het algemene kennisniveau van de deelnemers aan de scopingsbijeenkomst aangaande radon op eenzelfde peil te brengen en discussie- en beslispunten inzake de

  15. Radon in dwellings

    International Nuclear Information System (INIS)

    Erikson, B.E.; Boman, C.A.; Nyblom, L.; Swedjemark, G.A.

    1980-06-01

    The report presents the function of the ventilation by natural draught in three-storey houses. In some cases also the measurement of gamma radiation, radon and radon daughters was made. The investigation took place in Uppsala. The houses were built of light weight concrete made of alum-shale. The measurements showed that the contents of radon daughters were far below the provisional limits. (G.B.)

  16. Application of a radon model to explain indoor radon levels in a Swedish house

    CERN Document Server

    Font, L; Jönsson, G; Enge, W; Ghose, R

    1999-01-01

    Radon entry from soil into indoor air and its accumulation indoors depends on several parameters, the values of which normally depend on the specific characteristics of the site. The effect of a specific parameter is often difficult to explain from the result of indoor radon measurements only. The adaptation of the RAGENA (RAdon Generation, ENtry and Accumulation indoors) model to a Swedish house to characterise indoor radon levels and the relative importance of the different radon sources and entry mechanisms is presented. The building is a single-zone house with a naturally-ventilated crawl space in one part and a concrete floor in another part, leading to different radon levels in the two parts of the building. The soil under the house is moraine, which is relatively permeable to radon gas. The house is naturally-ventilated. The mean indoor radon concentration values measured with nuclear track detectors in the crawl-space and concrete parts of the house are respectively 75+-30 and 200+-80 Bq m sup - sup 3...

  17. Comparing summer and winter indoor radon and radon daughters activity in Campinas, Brazil

    International Nuclear Information System (INIS)

    Guedes, O.S.; Hadler, N.J.C.; Iunes, P.J.; Neman, R.S.; Souza, W.F.; Tello, S.C.A.; Paulo, S.R.

    2002-01-01

    We developed a technique - based on alpha particle track detection using CR-39 - where the activity originated from indoor radon can be potentially separated into three fraction: (i) radon in the air, (ii) radon daughters (RD), 218 Po and 214 Po, in the air and (iii) RD plated-out on the detector surface during exposure. In this work only a partial separation was carried out, then our results are limited to radon plus RD in the air and RD attached to detector surface. These activities can be separated if size and gray level of the round tracks are measured using an automatic optical microscopy system.Our group carried out an indoor radon and radon daughters (RD) survey in Campinas made up by a summer (November, 96 to May, 97) and a winter (May, 97 to November, 97) exposure, where the detectors were placed in the same rooms of the same dwellings (approximately 100) in both cases. Comparing winter and summer alpha activity for the detectors analyzed up to now, approximately 45 dwellings, we observed that: i) it seems that the source of radon is the material (brick and concrete mainly) making up walls, floor and ceiling of the dwellings, ii) there is no clear relationship between intensity of aeration and the activities measured in this work, and iii) the average ratio between winter and summer activity in the air (radon plus RD) is approximately equal to similar ratios observed in other countries, but for radon only. (author)

  18. Application of the can technique and radon gas analyzer for radon exhalation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fazal-ur-Rehman E-mail: fazalr@kfupm.edu.sa; Al-Jarallah, M.I.; Musazay, M.S.; Abu-Jarad, F

    2003-12-01

    A passive 'can technique' and an active radon gas analyzer with an emanation container were applied for radon exhalation rate measurements from different construction materials, viz. five marble seven ceramic and 100 granite tiles used in Saudi Arabia. The marble and ceramic tiles did not show detectable radon exhalation using the active radon gas analyzer system. However the granite tiles showed relatively high radon exhalations, indicating a relatively high uranium content. A comparison of the radon exhalation rates measured by the two techniques showed a linear correlation coefficient of 0.57. The radon exhalation rates from the granites varied from 0.02 to 6.58 Bq m{sup -2} h{sup -1} with an average of 1.35{+-}1.40 Bq m{sup -2} h{sup -1}. The geometric mean and the geometric standard deviation of the frequency distribution were found to be 0.80 and 3.1, respectively. The track density found on the nuclear track detectors in the can technique exposed to the granites, having high exhalation rates, varied linearly with exposure time with a linear correlation coefficient of 0.99. This experimental finding agrees with the theoretical prediction. The can technique showed sensitivity to low radon exhalation rates from ceramic, marble and some granite over a period of 2 months, which were not detectable by the active radon gas analyzer system. The reproducibility of data with both measuring techniques was found to be within a 7% deviation.

  19. Indoor radon and radon daughters survey at Campinas-Brazil using CR-39: First results

    International Nuclear Information System (INIS)

    Guedes, S.; Hadler, J.C.N.; Iunes, P.J.; Navia, L.M.S.; Neman, R.S.; Paulo, S.R.; Rodrigues, V.C.; Souza, W.F.; Tello, C.A.S.; Zuniga, A.

    1999-01-01

    The first results of a radon and radon daughters (RD) survey performed at Campinas-SP, Brazil, are presented. We employed a technique that, potentially, makes possible to measure the radon and RD activity in the air and to separate from this result the activity of radon, alone. In this preliminary paper only the former activity is studied

  20. Indoor radon and radon daughters survey at Campinas-Brazil using CR-39: First results

    CERN Document Server

    Guedes, S; Iunes, P J; Navia, L M S; Neman, R S; Paulo, S R; Rodrigues, V C; Souza, W F; Tello, C A S; Zúñiga, A G

    1999-01-01

    The first results of a radon and radon daughters (RD) survey performed at Campinas-SP, Brazil, are presented. We employed a technique that, potentially, makes possible to measure the radon and RD activity in the air and to separate from this result the activity of radon, alone. In this preliminary paper only the former activity is studied.

  1. El daminozide aumenta el diámetro de inflorescencia del crisantemo (Dendranthema grandiflora Tzvelev., cultivar polaris white

    Directory of Open Access Journals (Sweden)

    Á. G. Esquivel-Pool

    2005-01-01

    Full Text Available Se probaron varias concentraciones (1,000, 2,000, 3,000, 4,000 y 5,000 mg·litro-1 de daminozide sobre plantas de crisantemo cv. Polaris White, en maceta y se midieron el incremento del diámetro del tallo, altura de la planta, número de nudos, longitud de entrenudos, diámetro de la inflorescencia, biomasa y área foliar para comparar su efecto contra un testigo. La concentración de 1,000 mg·litro-1 provocó que los tallos incrementaran su diámetro 10.08 % en comparación con el testigo en tanto que con 4,000 mg·litro-1 el diámetro del tallo se redujo 8 %. Los entrenudos disminuyeron su longitud hasta 76 % con 4,000 mg·litro-1 en comparación con el testigo. Concentraciones iguales o mayores a 2,000 mg·litro-1 redujeron hasta en 34.3 % la altura de la planta. El daminozide favoreció el crecimiento de las inflorescencias incrementando su diámetro 31.22 % en promedio

  2. Radon as a hydrological indicator

    Energy Technology Data Exchange (ETDEWEB)

    Komae, Takami [National Research Inst. of Agricultural Engineering, Tsukuba, Ibaraki (Japan)

    1997-02-01

    The radon concentration in water is measured by a liquid scintillation method. After the radioactive equilibrium between radon and the daughter nuclides was attained, the radon concentration was determined by the liquid scintillation analyzer. {alpha}-ray from radon, then two {beta}- and two {alpha}-ray from the daughter nuclei group were released, so that 500% of the apparent counting efficiency was obtained. The detector limit is about 0.03 Bq/l, the low value, which corresponds to about 5.4x10{sup -15} ppm. By determining the radon concentration in groundwater, behavior of radon in hydrological process, the groundwater exchange caused by pumping and exchange between river water and groundwater were investigated. The water circulation analysis by means of radon indicator in the environment was shown. By using the large difference of radon concentration between in river water and in groundwater, arrival of injected water to the sampling point of groundwater was detected. (S.Y.)

  3. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement; Medida de los descendientes del radon en aire por Espectrometria Alfa

    Energy Technology Data Exchange (ETDEWEB)

    Acena, M L; Crespo, M T

    1989-07-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs.

  4. Control of radon in Finnish workplaces

    International Nuclear Information System (INIS)

    Markkanen, M.

    2002-01-01

    Natural radiation in Finland is regulated in the Finnish Radiation Act from 1992. Occupational exposure to natural radiation is regulated by an amendment of the Radiation Decree in 1998. The most important issues in Finland are radon in workplaces, radioactivity in drinking water and in building materials, and mining and industrial processes. Radon levels in mines have been measured regularly since 1972. Finland has an action level for radon in workplaces of 400 Bq/m 3 . Radon prone areas have been identified primarily from measurements of radon in dwellings. Radon measurements are compulsory in workplaces in radon prone areas unless it can be shown by other means that radon levels are low. A programme focusing on radon in workplaces was initiated in 1992. To date, radon measurements have been carried out in 10,000 workplaces and remedial actions have been taken in 200 of these. The average reduction in radon concentration in remediated buildings is about 1,500 Bq/m 3 . Identification of NORM industries is based on the radionuclide content of the materials used (>1.4 Bq/g U and >0.4 Bq/g Th). The occupational exposure should not exceed 1 mSv/y (excluding radon)

  5. Lessons from radon

    International Nuclear Information System (INIS)

    Nichols, M.

    1993-01-01

    At EPA there is a public outreach program that the Office of Air and Radiation (OAR) has developed for radon. To meet the difficult challenge radon presented, OAR's Radon Division developed working relationships with national nonprofit groups who share a mission. These groups have well-established communication networks with their memberships for advancing their goals. Such diverse groups as the American Lung Association, the Advertising Council, the National Association of Counties (NACo), the Consumer Federation of America, the National Association of Homebuilders, and the National Safety Council have joined with EPA to reduce radon health risks. Through this alliance, EPA has been able to take advantage of communication channels that it could never replicate on tis own. Every group working with EPA disseminates the radon message through its own established channels to reach its constituency. These partners wield authority in their fields and are ideal for addressing the concerns of their audiences

  6. Radon mitigation in schools

    International Nuclear Information System (INIS)

    Leovic, K.W.; Craig, A.B.; Saum, D.W.

    1990-01-01

    This article reports on radon mitigation in school buildings. Subslab depressurization (SSD) has been the most successful and widely used radon reduction method in houses. Thus far, it has also substantially reduced radon levels in a number of schools. Schools often have interior footings or thickened slabs that may create barriers for subslab air flow if a SSD system is the mitigation option. Review of foundation plans and subslab air flow testing will help to determine the presence and effect of such barriers. HVAC systems in schools vary considerable and tend to have a greater influence on pressure differentials (and consequently radon levels) than do heating and air-conditioning systems encountered in the radon mitigation of houses. As part of any radon mitigation method, ASHRAE Standard 62-1989 should be consulted to determine if the installed HVAC system is designed and operated to achieve minimum ventilation standards for indoor air quality

  7. Health effects of radon

    International Nuclear Information System (INIS)

    Easterly, C.

    1994-01-01

    Exposure of people to radon has taken on increased interest during the last decade because of the understanding that buildings can serve to trap radon and its daughters, and thereby build up undesirable concentrations of these radioactive elements. Numerous studies of underground miners (often uranium miners) have shown an increased risk of lung cancer in comparison with nonexposed populations. Laboratory animals exposed to radon daughters also develop lung cancer. The abundant epidemiological and experimental data have established the carcinogenicity of radon progeny. Those observations are of considerable importance, because uranium, from which radon and its progeny arise, is ubiquitous in the earth's crust, including coal mines. Risk estimates of the health effects of long-term exposures at relatively low levels require continued development, especially to address the potential health effects of radon and radon daughters in homes and occupational settings where the exposure levels are less than levels in underground uranium and other metal mines that have been the subject of epidemiological studies. Two approaches can be used to characterize the lung-cancer risks associated with radon-daughter exposure: mathematical representations of the respiratory tract that model radiation doses to target cells and epidemiological investigation of exposed populations, mainly underground uranium miners. The mathematically-based dosimetric approach provides an estimate of lung cancer risk related to radon-daughter exposure based specifically on modeling of the dose to target cells. The various dosimetric models all require assumptions, some of which are not subject to direct verification, as to breathing rates; the deposition of radon daughters in the respiratory tract; and the type, nature, and location of the target cells for cancer induction. The most recent large committee effort drawn together to evaluate this issue was sponsored by the National Research Council

  8. Radon in Syrian houses

    International Nuclear Information System (INIS)

    Othman, I.; Hushari, M.; Raja, G.; Alsawaf, A.

    1996-01-01

    A nationwide investigation of radon levels in Syrian houses was carried out during the period 1991-1993. Passive radon diffusion dosemeters using polycarbonate detectors were distributed in houses all over Syria. Detectors were subjected to electrochemical etching to reveal latent tracks of alpha particles. The mean radon concentration in Syrian houses was found to be 45 Bq m -3 with some values several times higher. This investigation indicated that there were a few houses in Syria that require remedial action. Most houses that have high levels of radon were found in the southern area, especially in the Damascus governorate. The study also indicated that radon concentrations were higher in old houses built from mud with no tiling. (author)

  9. The therapeutic use of radon; Radon als Heilmittel

    Energy Technology Data Exchange (ETDEWEB)

    Deetjen, P [Innsbruck Univ. (Austria). Inst. fuer Physiologie und Balneologie

    1995-09-01

    Spas with a somewhat elevated concentration of Radon{sup 222} (between 300 and 3000 Bq/l) are described to achieve good clinical results in the treatment of chronic rheumatic diseases. Recently a prospective randomized doubel-blind-study proved the pain reducing efficacy of Radon therapy in patients with cervical pain. Studies in experimental animal models have accumulated remarkable data in tissues and organs that provide a rationale to explain the observed effects of Radon therapy in patients. (orig.) [Deutsch] In verschiedenen europaeischen und asiatischen Laendern werden oft schon seit vielen Jahrhunderten Quellen als besonders heilkraeftig beschrieben, die eine etwas erhoehte Aktivitaet an Radon{sup 222} aufweisen (etwas zwischen 300 und 3000 Bq/l). Neuerdings liegt auch eine prospektive randomisierte Doppelblind-Studie vor, die den klinischen Nachweis der Schmerzlinderung durch eine Radonkur erbringt. In tierexperimentellen Untersuchungen wurden unter Radonexposition zahlreiche stimulierende Effekte auf Zellstoffwechsel, Immunabwehr, Abbau toxischer Radikale, DNA-Reparatur-Systeme oder Synthese von Mediatorsubstanzen gemessen, die rationale Ansaetze fuer das Verstaendnis der Wirkung einer Radonexposition im niedrigen Dosisbereich ergeben. (orig.)

  10. Radon and its measurement

    International Nuclear Information System (INIS)

    Penzo, Silvia

    2006-03-01

    The work reviews the topics concerning the problem of the indoor radon and its measurement. The initial stage deals with the general features of radon, from the historical remarks about its discovery to the formation mechanisms in the soil, then passing to describe the transport processes that lead the radon to enter into the buildings. The mean radon concentration distribution among the Italian regions is reported and compared with the situation in the other countries of the world. A particular importance is given to present the national law concerning the radioprotection from the natural sources of ionizing radiations; a paragraph is completely devoted to this argument and to discuss the differences between the Italian approach and the regulations applied in the Test of Europe for both workplaces and dwellings. Chapter 3 describes the different detectors and methods to measure the radon and its short mean live decay products concentrations, together with the operative procedures and guides provided by the Italian law and by the international bodies. As an example of typical radon passive measurement device. the new ENEA detector developed at the Institute of Radioprotection is presented and discussed. Appendix 1 is entirely devoted to discuss the main remedial actions for decreasing the radon indoor concentration both for old and new buildings; appendix 2 reports the main quantities related to radon and radioprotection [it

  11. Concentraciones de yodo en orina y en sal de consumo en mujeres entre 12 a 49 años del Perú

    Directory of Open Access Journals (Sweden)

    Carolina Tarqui-Mamani

    Full Text Available Objetivos. Determinar las concentraciones de yodo en orina y sal de consumo en mujeres entre 12 a 49 años en Perú. Materiales y métodos. Se realizó un estudio observacional y transversal. Durante el 2012 y 2013, se incluyó mujeres entre 12 a 49 años residentes en los hogares peruanos seleccionadas mediante un muestreo probabilístico, estratificado y multietápico. La determinación de yodo en orina se realizó por espectrofotometría basada en la reacción de Sandell-Kolthoff. La evaluación cualitativa de yodo en sal se realizó por yoditest y la cuantitativa por volumetría. El procesamiento se realizó mediante muestras complejas con ponderaciones. Se obtuvo medianas, rango intercuartílico y percentiles. Resultados. La mediana de yoduria en las participantes fue 250,4 ug/L; los departamentos con medianas de yoduria elevadas fueron: Moquegua (389,3 ug/L; Tacna (320,5 ug/L; Madre de Dios (319,8 ug/L, y Ucayali (306,0 ug/L; mientras que Puno (192,9 ug/L; Piura (188,1 ug/L y Tumbes (180,5 ug/L tuvieron medianas dentro de lo recomendado por la OMS. La mediana de yoduria en gestantes fue 274,6 ug/L (RIQ: 283 ug/L. El 82,5% de las muestras de sal tuvieron yodo ≥30 ppm y 1,9% tuvo valores de 0 ppm. Conclusiones. La mediana de yoduria en las mujeres peruanas está por encima de lo recomendado por la OMS y la mayoría de las muestras de sal tuvieron concentraciones adecuadas de yodo según la OMS

  12. Evaluation of the performance characteristics of radon and radon-daughter concentration measurement devices under controlled environmental conditions

    International Nuclear Information System (INIS)

    Pearson, M.D.

    1989-04-01

    The Technical Measurements Center (TMC) conducted a study to expose 10 radon and 7 radon-daughter concentration measurement devices in the DOE/GJPO Radon/Radon-Daughter Environmental Chamber for a series of 24 controlled-environment tests. The tests evaluated the devices' response to temperature, relative humidity, dew point, condensation-nuclei concentration, radon-daughter/radon equilibrium ratio, and non-uniform radon and radon-daughter concentration. Devices were evaluated for linear response as a function of concentration. In addition to response to environmental parameters, the evaluation included determining the utility of the devices in providing reasonable assurance of compliance with the radon and radon-daughter concentration standards for DOE remedial action programs. This reasonable assurance criterion is based on a coefficient of variation of 25 percent for devices deployed for year-long measurements and a coefficient of variation of 18 percent for devices deployed for intermittent sampling. 39 refs., 65 figs., 33 tabs

  13. Radon in public buildings

    International Nuclear Information System (INIS)

    Schulz, H.; Flesch, K.; Hermann, E.; Loebner, W.; Leissring, B.

    2009-01-01

    From the Free State of Saxony, a study was commissioned to survey how reliable measurements to characterize the radon situation in public buildings at a reasonable financial and human effort can be carried out to reduce radiation exposure in public buildings. The study approach was for 6 objects. To characterize the radon situation the time evolution measurement of radon concentrations of more than 1 to 2 weeks turned out to be sufficient. A novel data analysis enables the identification of a ''typical daily alteration of the radon concentration'' depending on the ventilation conditions and the daily use of the offices or class rooms. The identification of typical diurnal radon variations for the working time and weekends or holidays is of fundamental importance for assessing the exposure situation in public buildings. It was shown that the radon concentration during working time are in general much lower than in the times when the buildings (offices) are unused. It turned out that the long-term radon measurements with nuclear track detectors within distinct time regimes (day / night, working hours / leisure time) by utilizing switch modules are very efficient to estimate the actual exposure. (orig.)

  14. Improved thomas formula for radon measurement

    International Nuclear Information System (INIS)

    Ji Changsong

    1991-06-01

    The FT 648 type portable absolute radon meter has been developed and the designing principle of this instrument is introduced. The absolute radon meter differs from relative radon meter. By using structure parameters, operating parameters and readout of this instrument, the radon content of measured gas is obtained directly without calibration in advance. Normally, the calibration is done by a standard radioactive gaseous source of which the radon concentration is known. The systematic error is removed by adding filter-efficiency Σ, α self-absorption correction β, energy spectrum correction S, geometric factor Ω of probe and gravity dropping correction factor G to the Thomas formula for radon measurement of two-filter method. The atmosphere radon content, which is given in hour-average, in Beijing area was measured by FT 648 type absolute radon meter. The measurement lasted continuously for several days and nights and a 'saddle shape' of radon content-time curve was observed. The day's average radon content was 8.5 Bq·m -3

  15. Technique and equipment for measuring volume activity of radon in the air of radon laboratories and clinics

    International Nuclear Information System (INIS)

    Vorob'ev, I.B.; Krivokhatskij, A.S.; Nekrasov, E.V.; Nikolaev, V.A.; Potapov, V.G.; Terent'ev, M.V.

    1990-01-01

    Usability of a new equipment-technique combination for measuring radon activity in the air of radon laboratories and balneological clinics is studied. The complex includes nitrate-cellulose detector, radon chamber, Aist, Istra type spark counters and technique of spark counting. The method sensitivity is 50 Bqxm 3 , the error is 30%. Usability and advisability of track method in radon laboratories and balneological clinics for simultaneous measurement in several points of integral volumetric radon activities are confirmred. The method permits to carry out rapid and accurate bulk investigations. The results of determining mean volumetric radon activity in the air in different points of radon laboratory and radon clinics are presented

  16. Influencia del tráfico en la acumulación de metales pesados sobre vías urbanas: Torrelavega (España-Soacha (Colombia

    Directory of Open Access Journals (Sweden)

    Carlos Alfonso Zafra Mejía

    2013-01-01

    Full Text Available Asociado al suelo de áreas con una alta densidad de tráfico se han detectado elevadas concentraciones de metales. Los usuarios de las vías y aquéllos que viven en ambientes cercanos están potencialmente expuestos. Este artículo presenta un estudio del comportamiento de la concentración de metales pesados asociados con el sedimento acumulado sobre superficies viales (Torrelavega-España y Soacha-Colombia. Se distinguieron dos tipos de muestras: la aspirada directamente y la recolectada tras un barrido. Se determinó su distribución granulométrica (63-2800 μm y la concentración de metales (Pb, Zn, Cu, Cr, Cd y Ba asociada con cada fracción de tamaño por medio de espectrometría de absorción atómica de llama y de plasma inductivamente acoplado con espectrometría de masas. Los resultados mostraron que el sedimento con un mayor tiempo de residencia sobre la superficie estuvo más expuesto a la trituración generada por el tráfico (i.e., granulometría más fina; de esta manera, probablemente tendió a presentar una mayor susceptibilidad a la suspensión por el viento y la turbulencia del tráfico. En este sentido, la fracción de tamaño inferior a 63 μm presentó las mayores concentraciones. A mayor tiempo de residencia del sedimento sobre la superficie, mayores concentraciones metálicas asociadas. Las zonas con una mayor densidad de tráfico tienden a presentar las mayores concentraciones. Además, las calzadas con un mayor uso como línea de aparcamiento tienden a presentar mayores concentraciones, a pesar de registrar una menor densidad de tráfico. En las ciudades de investigación, el Pb supera los límites establecidos por la legislación utilizada como de referencia.

  17. Radon in dwellings the national radon survey Cork and Kerry

    International Nuclear Information System (INIS)

    McGarry, A.T.; Fennell, S.G.; Mackin, G.M.; Madden, J.S.

    1998-07-01

    This report presents the results of the third phase of the National Radon Survey carried out by the Radiological Protection Institute of Ireland. The counties included in this phase are Cork and Kerry. The average radon concentrations for the houses measured in these counties were 76 Bq/m 3 and 70 Bq/m 3 . The measurement data were grouped on the basis of the 10 km grid squares of the Irish National Grid System and used to predict the percentage of dwellings in each grid square which exceeds the Reference Level of 200 Bq/m 3 . Grid squares where this percentage is predicted to be 10% or higher are designated High Radon Areas. The health effects of exposure to high radon levels are discussed and recommendations are made regarding both new and existing dwellings. (author)

  18. Influencia de las concentraciones de aceite y emulsionante en las propiedades reológicas de emulsiones aceite en agua del tipo salsa fina

    Directory of Open Access Journals (Sweden)

    Franco, José María

    1995-04-01

    Full Text Available The viscous and viscoelastic behaviour of food emulsions containing a mixture of egg yolk and sucrose stearate as a function of oil and sucrose stearate concentrations were studied. Oil concentrations ranged between 40- 55% w/w for emulsions containing 5% w/w sucrose stearate and sucrose ester concentrations varied between 0-10% w/w for emulsions containing 50% w/w oil. steady flow, linear oscillatory shear tests and droplet size distribution measurements were carried out. An increase in oil or emulsifier concentration produced an increase in both the steady-state viscosity and in the viscoelastic functions. The results have been explained on the basis of the relationship between the structural parameters and the rheology of the emulsions studied.

    Se ha estudiado la influencia que ejercen las concentraciones de aceite y emulsionante sobre el comportamiento viscoso y viscoelástico de emulsiones alimentarias con bajo contenido en aceite estabilizadas por una mezcla de yema de huevo y estearato de sacarosa. Se han preparado emulsiones variando la concentración de aceite entre el 40 y el 55% p/p en emulsiones con un 5% p/p en sucroéster y la concentración de sucroéster entre el 0 y el 10% p/p manteniendo un 50% p/p en aceite. Se han realizado medidas reológicas en cizalla oscilatoria dentro del intervalo de viscoelasticidad lineal, representativas de un estado imperturbado, y medidas en cizalla estacionaria, que causan una gran destrucción estructural. También se han determinado las distribuciones de tamaños de gota. Un aumento en el contenido de aceite o emulsionante produce un aumento de las funciones viscoelásticas dinámicas y de la viscosidad estacionaria. Estos resultados se explican en función de los parámetros estructurales de las emulsiones.

  19. Radon programmes and health marketing.

    Science.gov (United States)

    Fojtikova, Ivana; Rovenska, Katerina

    2011-05-01

    Being aware of negative health effects of radon exposure, many countries aim for the reduction of the radon exposure of their population. The Czech radon programme was commenced >20 y ago. Since then experts have gathered a lot of knowledge, necessary legislation has been enacted, tens of thousands of inhabitants have been offered free measurement and subsidy for the mitigation. Despite the effort, the effectiveness of the radon programme seems to be poor. Newly built houses still exhibit elevated radon concentrations and the number of houses mitigated is very low. Is it possible to enhance the effectivity of radon programme while keeping it on a voluntary basis? One possible way is to employ health marketing that draws together traditional marketing theories and science-based strategies to prevention. The potential of using marketing principles in communication and delivery of radon information will be discussed.

  20. Leukaemia risks and radon

    International Nuclear Information System (INIS)

    Wolff, S.P.

    1991-01-01

    A correlation has been established between domestic radon exposure and mutation in peripheral T lymphocytes. Some caution must be exercised, however, in interpreting this result as evidence that levels of domestically encountered radon are sufficient to cause leukaemogenic chromosomal alterations. Radon may simply be acting as a surrogate for some other mutagenic factor. Correlations with Local Authority statistics collected in the United Kingdom 1981 Census appear to show that lower domestic radon levels reflect relatively greater socioeconomic deprivation whereas higher levels reflect greater prosperity. The relative risk of lymphoproliferative disease correlates with the same factors that determine domestic radon levels at the county level. Putative relationships between domestic radon exposure and cancer thus need to be controlled for socioeconomic status and associated factors, at least at the county level. (The correlations may not apply to smaller areas.) Similarly, the causative factors underlying the relationships between higher regional socioeconomic status and leukaemia require closer examination. (author)

  1. Radon in workplaces: First results of an extensive survey and comparison with radon in homes

    International Nuclear Information System (INIS)

    Bucci, S.; Pratesi, G.; Viti, M. L.; Pantani, M.; Bochicchio, F.; Venoso, G.

    2011-01-01

    Extensive radon surveys have been carried out in many countries only in dwellings, whereas surveys in workplaces are rather sparse and generally restricted to specific workplaces/activities, e.g. schools, spas and caves. Moreover, radon-prone areas are generally defined on the basis of radon surveys in dwellings, while radon regulations use this concept to introduce specific requirements in workplaces in such areas. This approach does not take into account that work activities and workplace characteristics can significantly affect radon concentration. Therefore, an extensive survey on radon in different workplaces have been carried out in a large region of Italy (Tuscany), in order to evaluate radon distribution in workplaces over the whole territory and to identify activities and workplace characteristics affecting radon concentration. The results of this extensive survey are compared with the results of the survey carried out in dwellings in the same period. The workplaces monitored were randomly selected among the main work activities in the region, including both public and industrial buildings. The survey monitored over 3500 rooms in more than 1200 buildings for two consecutive periods of ∼6 months. Radon concentration was measured by means of passive nuclear track detectors. (authors)

  2. The significance of radon in radioactive pollution of environment. Pt. 2. Radon effect on living organism

    International Nuclear Information System (INIS)

    Kossakowski, S.; Dziura, A.; Kossakowski, A.

    1998-01-01

    Authors review the history of radon monitoring. Epidemiological studies of lung cancer and its correlation to radon concentration in mines and buildings are described. The influence of radon on animals living in the buildings built from waste materials is described. Authors review plans concerning creation of radon monitoring system in Poland. The necessity of monitoring influence of radon on animals is described

  3. Caracterización espectral y mineralógica de los suelos del valle del río Cauca por espectroscopía visible e infrarroja (400 - 2.500 nm

    Directory of Open Access Journals (Sweden)

    Bastidas Obando Ernesto

    2010-08-01

    Full Text Available Las librerías espectrales se utilizan para identificar diferentes
    tipos de suelo a partir de análisis espectrales que caracterizan su
    composición mineralógica y química. Los objetivos del presente
    trabajo consistieron en determinar si existen diferencias en el
    perfil espectral de los suelos del valle geográfico del río Cauca
    a nivel de subgrupo taxonómico; y cuantificar en sus perfiles
    espectrales la abundancia de minerales arcillosos. Por medio
    de un análisis de conglomerados se seleccionaron las muestras
    más homogéneas de cada subgrupo taxonómico para construir
    el perfil espectral de cada uno de ellos. El modelo linear spectral
    unmixing se utilizó para determinar las concentraciones de
    minerales arcillosos. A nivel de subgrupo taxonómico se observaron
    diferencias en la magnitud de los perfiles espectrales, así
    como en sus longitudes de onda a los 1.400, 1.900 y 2.200 nm.
    El modelo utilizado permite caracterizar de manera objetiva las
    concentraciones de minerales arcillosos de cada suelo a partir
    de su perfil espectral.

  4. Monitoring of radon concentration in dwellings

    International Nuclear Information System (INIS)

    Kurosawa, Ryuhei

    1991-01-01

    Radon problems in dwellings have recently received much attention. Radon concentration in dwellings, as well as in the general environment, varies with various factors such as meteorological conditions and soil components. Therefore, a long term monitoring of radon concentration is required to obtain an average concentration. This paper reviews a passive type radon monitor that is handy and allows a long term radon monitoring. It provides the structure and principle of the radon monitor, covering the type, filter function, sensitivity of diffusion collecting type (cup type), electrostatic collecting type, adsorption collecting type, and detector of radon monitor. Actual examples of the radon monitor are also given. Radon daughter nuclides will have become major foci of exposure countermeasures. In the future, the development of a passive type monitor for determining potential alpha energy concentration is required. (N.K.)

  5. Intercomparison of active and passive instruments for radon and radon progeny in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng-Wu; Knutson, E.O.

    1995-02-01

    An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- and beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within ±10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement

  6. Workshop on dosimetry for radon and radon daughters

    International Nuclear Information System (INIS)

    Turner, J.E.; Holoway, C.F.; Loebl, A.S.

    1978-05-01

    Emphasis is placed on the dosimetry for radon and daughters, rather than on monitoring and instrumentation. The objectives of the meeting were to exchange scientific information, to identify problem areas in radon-daughter dosimetry, and to make any observations or recommendations by the participants through issuance of this report. The discussion topics included the history of dosimetry for radon and daughters, human data, aerosols, deposition and movement in the respiratory tract, dose calculations, dose-to-working-level-month (WLM) conversion factors, animal experiments, and the development of regulations and remedial criteria for reducing population exposures to radon daughters. This report contains a summary of Workshop discussions plus individual statements contributed by several of the participants. The outstanding problem areas from the standpoint of dosimetry appear to involve the appropriate lung organ mass to be used (average lung-tissue dose vs. high-level local dose); recognition of the discrete, rather than continuous, structure of the mucus; lack of knowledge about lung clearance; the variability of dose with the degree of disequilibrium and the unattached fraction of radon daughters for a given WLM; and questions about the character of uranium mine atmospheres actually breathed in the older mines from which much of the epidemiological information originates. The development of criteria for taking remedial action to reduce exposures involves additional concerns of basing long-term risk assessment on short-term sampling and applying WLM data for miners to general populations

  7. Extracción del ADN de Fusarium Oxysporum f.sp. Dianthi

    OpenAIRE

    Sixta T. Martínez; Carlos Y. Soto

    2010-01-01

    Se estudia la utílización de dos métodos para la extracción del ADN del Fusarium o.xy.sporum f.sp. Dianthi. En los dos métodos la pared del hongo se rompió con nitrógeno líquido, uno de ellos empleó como solución extractora bromuro de cetiltrimetil amonio (BCTA) y el otro una solución de sacarosa con altas concentraciones de protcasa y EDTA. Para la desproteinización ambos métodos utilizaron soluciones de fcnol-clorofonno y enzimas proteolítícas. El ADN obtenido se digirió con enzimas d...

  8. The Pennsylvania radon story

    International Nuclear Information System (INIS)

    Gerusky, T.M.

    1987-01-01

    In December 1984, the Pennsylvania Bureau of Radiation Protection found itself confronted with the discovery of a home in eastern Pennsylvania having the highest level of radon daughters ever reported. The Bureau responded with a massive radon monitoring, educational, and remediation effort. As of November, 1986, over 18,000 homes had been screen for radon daughters, of which approximately 59% were found to have levels in excess of the 0.020 Working Level guideline. Pennsylvania's response to the indoor radon problem is detailed in this article

  9. Radon problems

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1985-01-01

    This chapter examines the health hazards resulting from the release of naturally occurring radioactive gas derived from the decay of uranium. It is estimated that random inhalation is now causing about 10,000 fatal lung cancers per year in the US. Radon is constantly being generated in rocks and soils (in which uranium is naturally present) and in materials produced from them (e.g., brick, stone, cement, plaster). It is emphasized that radon levels in buildings are typically 5 times higher than outdoors because radon diffusing up from the ground below or out of bricks, stone, cement, or plaster is trapped inside for a relatively long time

  10. Unattached radon daughter atoms and radon daughter equilibrium ratios in uranium mines. Final report

    International Nuclear Information System (INIS)

    Holaday, D.A.

    1972-01-01

    Uranium mines in Colorado and New Mexico were surveyed for airborne concentrations of radon (10043922) and radon daughters. A procedure for measuring individual daughters and the fraction of each existing as free atoms was developed and used for field monitoring. Samples were taken in working areas and particle counts were made. The data was analyzed to determine the ratio of radon to radon daughters as well as the ratios among the radon daughters. The author concludes that since the radon to working level ratios have not changed much in 20 years, using the ratio as the basis for estimating relative biological hazard is just as uncertain now as then. The large number of daughters present as free atoms indicate that the lung radiation doses calculated using any of the lung models need reexamination

  11. Radon Research Program, FY-1990

    International Nuclear Information System (INIS)

    1991-03-01

    The Department of Energy (DOE) Office of Health and Environmental Research (OHER) has established a Radon Research Program with the primary objectives of acquiring knowledge necessary to improve estimates of health risks associated with radon exposure and also to improve radon control. Through the Radon Research Program, OHER supports and coordinates the research activities of investigators at facilities all across the nation. From this research, significant advances are being made in our understanding of the health effects of radon. OHER publishes this annual report to provide information to interested researchers and the public about its research activities. This edition of the report summarizes the activities of program researchers during FY90. Chapter 2 of this report describes how risks associated with radon exposure are estimated, what assumptions are made in estimating radon risks for the general public, and how the uncertainties in these assumptions affect the risk estimates. Chapter 3 examines how OHER, through the Radon Research Program, is working to gather information for reducing the uncertainties and improving the risk estimates. Chapter 4 highlights some of the major findings of investigators participating in the Radon Research Program in the past year. And, finally, Chapter 5 discusses the direction in which the program is headed in the future. 20 figs

  12. Radon - The management of the risk related to radon

    International Nuclear Information System (INIS)

    2010-01-01

    This leaflet briefly explains what radon is, where it comes from, and what it becomes. It indicates and briefly comments its concentrations in French departments, describes how radon can affect our health (lung cancer), describes how the risk can be reduced in buildings, and indicates the existing regulatory provisions

  13. Radon programmes and health marketing

    International Nuclear Information System (INIS)

    Fojtikova, I.; Rovenska, K.

    2011-01-01

    Being aware of negative health effects of radon exposure, many countries aim for the reduction of the radon exposure of their population. The Czech radon programme was commenced >20 y ago. Since then experts have gathered a lot of knowledge, necessary legislation has been enacted, tens of thousands of inhabitants have been offered free measurement and subsidy for the mitigation. Despite the effort, the effectiveness of the radon programme seems to be poor. Newly built houses still exhibit elevated radon concentrations and the number of houses mitigated is very low. Is it possible to enhance the effectivity of radon programme while keeping it on a voluntary basis? One possible way is to employ health marketing that draws together traditional marketing theories and science-based strategies to prevention. The potential of using marketing principles in communication and delivery of radon information will be discussed. (authors)

  14. Radon in buildings

    International Nuclear Information System (INIS)

    Ryan, N.M.; Finn, M.

    1995-01-01

    This guide is intended to inform designers, contractors, householders and other building owners about radon in buildings and to provide guidance where it has been decided to take action to reduce radon levels. It gives some pointers to good practice insofar as it relates to non complex buildings of normal design and construction. Reference is made to the usual ways of reducing l;levels of radon and guidance is given on sources of further information. I

  15. Radon in dwellings the national radon survey Galway and Mayo

    International Nuclear Information System (INIS)

    McGarry, A.T.; Fennell, S.G.; Mackin, G.M.; Madden, J.S.; O'Colmain, M.

    1999-07-01

    This report presents the results of the final phase of the National Radon Survey carried out by the Radiological Protection Institute of Ireland. The counties included in this phase are Galway and Mayo. The average radon concentrations for the houses measured in these counties were 112 Bq/m 3 and 100 Bq/m 3 , respectively. The measurement data were grouped on the basis of the 10 km grid squares of the Irish National Grid System and used to predict the percentage of dwellings in each grid square which exceeds the Reference Level of 200 Bq/m 3 . Grid squares where this percentage is predicted to be 10% or higher are designated High Radon Areas. The health effects of exposure to high radon levels are discussed and recommendations are made regarding both new and existing dwellings. (author)

  16. The use of mechanical ventilation with heat recovery for controlling radon and radon-daughter concentrations

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Boegel, M.L.; Hollowell, C.D.; Roseme, G.D.

    1980-01-01

    An energy research house in Maryland was found to have radon concentrations far in excess of recommended guidelines. A mechanical ventilation system with heat recovery was installed in this house to test its effectiveness as an energy-efficient control technique for indoor radon. Radon concentration was monitored continuously for two weeks under varying ventilation conditions (0.07 to 0.8 air changes per hour (ach)) and radon daughter concentrations were measured by grab-sample techniques about nine times daily during this period. At ventilation rates of 0.6 ach and higher radon and radon daughter levels dropped below guidelines for indoor concentrations. Comparison with other studies indicates that indoor radon buildup may be a problem in a considerable portion of houses characterized by their low infiltration rates. The use of mechanical ventilation systems with air-to-air heat exchangers may offer a practical, cost-effective, and energy-efficient means of alleviating not only the radon problem specifically but also the general deterioration of indoor air quality in houses designed or retrofitted to achieve low infiltration

  17. Measurement of radon concentration in water using the portable radon survey meter.

    Science.gov (United States)

    Yokoyama, S; Mori, N; Shimo, M; Fukushi, M; Ohnuma, S

    2011-07-01

    A measurement method for measuring radon in water using the portable radon survey meter (RnSM) was developed. The container with propeller was used to stir the water samples and release radon from the water into the air in a sample box of the RnSM. In this method, the measurement of error would be water was >20 Bq l(-1).

  18. Radon and radiation biology of the lung

    International Nuclear Information System (INIS)

    Crameri, R.; Burkart, W.

    1989-01-01

    The main papers presented at the meeting dealt with the behaviour of radon and the indoor environment, radiation biology of the lung, lung dosis and the possible cancer risk caused by radon in homes, contamination of the room air. A series of special papers treated the radon problem in detail: sources and transport mechanisms of radon, geological aspects of the radon radiation burden in Switzerland, radon in homes, search for radon sources, and the Swiss radon-programme RAPROS. 67 figs., 13 tabs., 75 refs

  19. Multivariate signal processing in measurements of radon and radon daughters in air

    International Nuclear Information System (INIS)

    Urbanski, P.; Machaj, B.

    2000-01-01

    Extensive measurements of radon and radon daughters concentration gauge in a radon chamber were carried out. Count rate 'spectra' against time at the output of radiation detectors were measured and registered. The count rate spectra were then processed employing Principal Component Regression (PCR). A root mean square error of the count rate was estimated. It was found that PCR processing removes a great part of count rate random fluctuations originating from the radiation statistics that results in a decrease of count rate random error. The root mean square error of count rate in a radon daughter monitor is about 3 times lower, which is equivalent to the error of the gauge with a 9 times higher air flow rate if no PCR processing is used. In case of the radon concentration gauge the increase of sensitivity is even higher and amounts to 5 times. (author)

  20. Radon measurements in indoor workplaces

    International Nuclear Information System (INIS)

    Tokonami, S.; Matsumoto, M.; Furukawa, M.; Fujimoto, K.; Fujitaka, K.; Pan, J.; Kurosawa, R.

    1996-01-01

    Radon measurements in several office buildings located in Tokyo were carried out with two types of device to study the time-dependent radon concentration in indoor workplaces. Both types of device use the electrostatic field for the collection of 218 Po onto the electrode of the detector. One provides an average radon concentration throughout the day. The other, in which a weekly timer is installed in the circuit of the electrode of the device, provides an average radon concentration during working hours (9:00-17:00, Monday-Friday). Although radon concentrations in Japanese dwellings have been found to be generally low, relatively high concentrations were observed in the office buildings. No consistent seasonal variation was recognised in this study. Little difference of average radon concentrations between working hours and the whole day was found throughout the year in two offices. On the other hand, a significant difference was observed in other offices. The operation of an air conditioner might change the radon concentration during working hours. From the results of radon measurements the average effective dose in the workplace was estimated to be 0.23 mSv for 2000 working hours in a year. (Author)

  1. Radon studies in Indian dwellings

    International Nuclear Information System (INIS)

    Khan, A.J.

    2000-01-01

    The indoor radon ( 222 Rn) concentration has been measured by Solid State Nuclear Track Detectors (SSNTDs) in large number of Indian dwellings. Radon concentrations were measured in different parts of the country. In the first study, radon concentrations were measured in 143 dwellings of Udaipur, Bikaner and Banswara towns of Rajasthan province. The distributions of the time-averaged indoor radon concentration in these three towns of the Rajasthan fit an approximately log normal distribution. The geometric mean (GM) values of radon concentrations in these three places were found to be 74 Bq m -3 , 46 Bq m -3 and 66 Bq m -3 with a geometric standard deviation (GSD) of 2.2, 2.2 and 2.5 respectively. In another study, radon concentrations were measured in about 150 dwellings of hilly regions of the country. The measurements were carried out in Kohima (Nagaland), Baijnath and Palampur (Himachal Pradesh). The distribution of radon concentration in Kohima dwellings was found to be approximately log normal, however, the radon distribution in Baijnath and Palampur dwellings seems to be bimodal. The GM values of the radon concentrations for 65 dwellings in Kohima and 43 dwellings in Baijnath and Palampur were 88 Bq m -3 and 134 Bq m -3 with GSD of 1.7 and 2.5 respectively. The results are discussed in detail. (author)

  2. Radon prevention coating in hot and humid environment

    International Nuclear Information System (INIS)

    Yang Yushan; Dong Faqin; Deng Yuequan; Qu Ruixue

    2013-01-01

    The radon prevention performance of a new self-made radon prevention coating was researched in the radon contamination provided by the releasing radon modules. With coating thickness of 0.8 mm, the radon mitigation efficiency in 1 # radon module concentration is optimal when the addition of defoaming agent is 0.3% (mass fraction). The radon mitigation efficiency increases with the coating thickness when the defoaming agent of 0.3% is added, but the radon mitigation efficiency tends to be stable as the coating thickness is more than 2.0 mm. The radon mitigation efficiency of radon prevention coating appended precipitated barium sulphate decreases obviously, and the addition of ash calcium, white cement and gesso don't decrease radon mitigation efficiency. The addition of white cement and gesso addition affects the radon prevention stability, while radon mitigation efficiency of radon prevention coating with ash calcium keeps a good performance. Under the hot and humid environment, the radon prevention coating still has good radon mitigation efficiency in 2 # radon module concentration. (authors)

  3. Radon in homes: The Alaskan experience

    International Nuclear Information System (INIS)

    Seifert, R.D.

    1990-01-01

    For the past four years, since radon was first found to be a concern in Alaska in 1986, the interest and awareness of radon as a special housing and health concern has continued to grow. This paper will discuss the features of a house in Alaska which would characterize it as at risk for radon, and also those efforts at mitigation which have been most effective in reducing radon under Alaskan conditions. Clearly radon must be able to enter a home in order to be a problem. Riefenstuhl and Kline (personal communication, 1988) have analyzed the conditions for radon transport from soils to home interiors very lucidly through the following scheme: four factors must exist in a house locale for it to be a radon at risk house. Two of the factors are geological in nature: (1) there must be adequate uranium and therefore ample radon to provide a source for transport; (2) there must be enough permeability in the soil to allow rapid soil gas movement to carry radon from its origin to the interior of the home within two half-lives of time (six days) or so. The other two factors are determined by the structure of the house itself and the way in which it is operated: (3) the house must have soil contact and imperfections, holes, cracks, intentional perforations which allow movement of soil gas with radon through the envelope of the basement or crawlspace; (4) there must be a lower pressure inside the house than in the soil so that soil gas flows into the house. All four of these characteristics are required to have radon be a problem. The absence of any single characteristic will eliminate radon (in general). This presents a series of options for mitigation of radon then, since elimination of any of the four characteristics will mitigate radon

  4. A calibration facility for radon fluxmeter

    International Nuclear Information System (INIS)

    Li Xianjie; Qiu Shoukang; Zhou Jianliang; Liu Chunkui; Pan Jialin; Yang Mingli

    1998-01-01

    Calibration facilities for radon fluxmeter with three kinds of different emanation medium have been developed. The stability of radon flux is 5%, 9% (RSD) respectively. The uniformity of radon flux is 4.5%, 8.5% (RSD) respectively. These specifications fulfill the calibration requirement for radon fluxmeter. The determination of radon flux of facility takes full account of eliminating the main error source-attenuation effect (including leakage and back diffusion etc.): not only prevent attenuation and make a relevant correction. Therefore the accuracy of determination is assured. The calibration, intercomparison of radon flux meter and the quantitatively evaluation on the measurement method of radon flux are made to be possible by the successful establishment of this facility. (author)

  5. Automatically processed alpha-track radon monitor

    International Nuclear Information System (INIS)

    Langner, G.H. Jr.

    1993-01-01

    An automatically processed alpha-track radon monitor is provided which includes a housing having an aperture allowing radon entry, and a filter that excludes the entry of radon daughters into the housing. A flexible track registration material is located within the housing that records alpha-particle emissions from the decay of radon and radon daughters inside the housing. The flexible track registration material is capable of being spliced such that the registration material from a plurality of monitors can be spliced into a single strip to facilitate automatic processing of the registration material from the plurality of monitors. A process for the automatic counting of radon registered by a radon monitor is also provided

  6. The householders' guide to radon

    International Nuclear Information System (INIS)

    1988-06-01

    This guide is a follow-up to the leaflet Radon in Houses which was issued previously by the Department of the Environment. It is intended for people who live in areas with high levels of radon. It is written particularly for householders whose homes have already been tested and found to have an appreciable level of radon. It explains what radon is, how it gets into houses and what the effects on health may be. It also outlines some of the ways of reducing the level of radon and gives guidance both on how to get the work done and likely costs. (author)

  7. Radon surveys and their implications

    International Nuclear Information System (INIS)

    Miles, J.C.H.; Cliff, K.D.; Dixon, D.W.; Green, B.M.R.; Strong, J.C.

    1989-01-01

    In the UK, as in other countries, radon daughter inhalation is the most significant cause of human exposure to ionising radiation either at home or at work whether one considers the mean or the maximum dose. Substantial studies of radon are under way in the UK, and the importance of radon is recognised in several spheres. NRPB investigations of the radon levels in buildings and mines are reported, the distributions of doses presented and risk factors calculated. The bases of radon limitation for workers and members of the public are given and the means of compliance discussed. (author)

  8. Radon exposure and lung cancer

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.; Faj, Z.; Radolic, V.; Suveljak, B.

    2003-01-01

    Although studies of radon exposure have established that Rn decay products are a cause of lung cancer among miners, the lung cancer risk to the general population from indoor radon remains unclear and controversial. Our epidemiological investigation of indoor radon influence on lung cancer incidence was carried out for 201 patients from the Osijek town. Ecological method was applied by using the town map with square fields of 1 km 2 and the town was divided into 24 fields. Multiple regression study for the lung cancer rate on field, average indoor radon exposure and smoking showed a positive linear double regression for the mentioned variables. Case-control study showed that patients, diseased of lung cancer, dwelt in homes with significantly higher radon concentrations, by comparison to the average indoor radon level of control sample. (author)

  9. Radon and radon-daughter concentrations in air in the vicinity of the Anaconda Uranium Mill

    International Nuclear Information System (INIS)

    Momeni, M.H.; Lindstrom, J.B.; Dungey, C.E.; Kisieleski, W.E.

    1979-11-01

    Radon concentration, working level, and meteorological variables were measured continuously from June 1977 through June 1978 at three stations in the vicinity of the Anaconda Uranium Mill with measurements integrated to hourly intervals. Both radon and daughters show strong variations associated with low wind velocities and stable atmospheric conditions, and diurnal variations associated with thermal inversions. Average radon concentration shows seasonal dependence with highest concentrations observed during fall and winter. Comparison of radon concentrations and working levels between three stations shows strong dependence on wind direction and velocity. Radon concentrations and working-level distributions for each month and each station were analyzed. The average maximum, minimum, and modal concentration and working levels were estimated with observed frequencies. The highest concentration is 11,000 pCi/m 3 on the tailings. Working-level variations parallel radon variations but lag by less than one hour. The highest working levels were observed at night when conditions of higher secular radioactive equilibrium for radon daughters exist. Background radon concentration was measured at two stations, each located about 25 km from the mill, and the average is 408 pCi/m 3 . Average working-level background is 3.6 x 10 -3

  10. Consumer's Guide to Radon Reduction

    Science.gov (United States)

    ... Labs and Research Centers Radon Contact Us Share Consumer's Guide to Radon Reduction: How to Fix Your ... See EPA’s About PDF page to learn more. Consumer's Guide to Radon Reduction: How to Fix Your ...

  11. Standardization of radon measurements

    International Nuclear Information System (INIS)

    Matuszek, J.M.; Hutchinson, J.A.; Lance, B.H.; Virgil, M.G.; Mahoney, R.J.

    1988-01-01

    Radon escaping from soil into homes appears to present the single greatest source of radiation exposure that most people will ever face. Measurement protocols for the relatively inert gas inextricably link the method of collection with the counting of the specimen. The most commonly used methods depend on the measurement of dislocation sites on plastic α-track detectors or on the adsorption of radon onto activated charcoal for subsequent counting of the γ-rays produced by decay of the radon progeny. The uncertainties inherent to the radon-measurement methods used commercially in the United States are far greater than those for measurements of other environmental radionuclides. The results of this preliminary study raise doubts as to whether existing proficiency-testing programs can provide assurance that radon-measurement methods are representative of actual conditions in any dwelling. 17 refs., 1 figs., 4 tabs

  12. Radon programme in the Czech Republic

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.

    2003-01-01

    The framework of the Radon programme in the Czech republic includes both precautionary measures and interventions. The programme informally started in early eighties has been now incorporated in national legislation (Atomic Act, Radiation Protection Decree, etc.). Aim of precautionary measures is to avert construction of building above natural radiation guidance levels (200 Bq/m 3 for indoor radon concentration and 0.5 Sv/h for gamma dose rate) by protection of new buildings against soil radon ingress, by regulation of natural radioactivity in building materials and supplied water. Aim of interventions is to identify buildings affected by enhanced natural radioactivity and help owners to put into effect reasonable remedial measures. Two sets of intervention levels for indoor natural exposure were established: guidance intervention levels 400 Bq/m 3 (indoor radon), 1.0 Sv/h (indoor gamma dose rate) and limit values 4000 Bq/m 3 and 10 Sv/h. The radon programme is based both on governmental and private activities. The governmental activities include representative and targeted indoor radon survey, subsidy for radon mitigation, mitigation test measurements and public information on radon issue. The private activities include radon measurement (radon index of building site, indoor measurements, radon diagnosis) and remedial measures. More than 100 commercial companies were authorised by Radiation Protection Authority (SUJB) to provide these measurements

  13. Radon survey techniques

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    The report reviews radon measurement surveys in soils and in water. Special applications, and advantages and limitations of the radon measurement techniques are considered. The working group also gives some directions for further research in this field

  14. Comparison of retrospective and contemporary indoor radon measurements in a high-radon area of Serbia

    International Nuclear Information System (INIS)

    Zunic, Z.S.; Yarmoshenko, I.V.; Kelleher, K.; Paridaens, J.; Mc Laughlin, J.P.; Celikovic, I.; Ujic, P.; Onischenko, A.D.; Jovanovic, S.; Demajo, A.; Birovljev, A.; Bochicchio, F.

    2007-01-01

    In Niska Banja, Serbia, which is a high-radon area, a comparison was made between two retrospective radon measuring methods and contemporary radon measurements. The two retrospective methods derive the radon concentrations that occurred in dwellings over longer periods in the past, based on the amount of trapped 210 Po on the surface of glass objects (surface traps, ST) or in the bulk of porous materials (volume traps, VT). Both surface implanted 210 Po in glass objects and contemporary radon in air were measured in 46 rooms, distributed in 32 houses of this radon spa-town, using a dual alpha track detector configuration (CR-39 and LR115) and CR-39 track etched detectors, respectively. In addition to the use of surface trap measurements, in 18 rooms (distributed in 15 houses) VT samples of suitable material were also collected, allowing to compare ST and VT retrospective radon concentration estimates. For each room, contemporary annual radon concentrations (CONT) were measured or estimated using seasonal correction factors. The distribution of the radon concentration in all data sets was found to be close to lognormal (Chi-square test > 0.05). Geometric means (GM) are similar, ranging from 1040 to 1380 Bq m -3 , whereas geometric standard deviations (GSD) for both the retrospective methods are greater than for the CONT method, showing reasonable agreement between VT, ST and CONT measurements. A regression analysis, with respect to the lognormal distribution of each data set, shows that for VT-ST the correlation coefficient r is 0.85, for VT-CONT r is 0.82 and for ST-CONT r is 0.73. Comparison of retrospective and contemporary radon concentrations with regard to supposed long-term indoor radon changes further supports the principal agreement between the retrospective and conventional methods

  15. The use of track registration detectors to reconstruct contemporary and historical airborne radon ( sup 2 sup 2 sup 2 Rn) and radon progeny concentrations for a radon-lung cancer epidemiologic study

    CERN Document Server

    Steck, D J

    1999-01-01

    Epidemiologic studies that investigate the relationship between radon and lung cancer require accurate estimates for the long-term average concentrations of radon progeny in dwellings. Year-to-year and home-to-home variations of radon in domestic environments pose serious difficulties for reconstructing an individual's long-term radon-related exposure. The use of contemporary radon gas concentrations as a surrogate for radon-related dose introduces additional uncertainty in dose assessment. Studies of glass exposed in radon chambers and in a home show that radon progeny deposited on, and implanted in, glass hold promise for reconstructing past radon concentrations in a variety of atmospheres. We developed an inexpensive track registration detector for the Iowa Radon Lung Cancer Study (IRLCS) that simultaneously measures contemporary airborne radon concentrations, surface deposited alpha activity density, and implanted sup 2 sup 1 sup 0 Po activity density. The implanted activity is used to reconstruct the cum...

  16. Quality assurance for radon measurements in Germany

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Foerster, E.; Schmidt, V.

    2005-01-01

    Full text: Radiation protection regarding work activities at workplaces with naturally occurring radiation has been regulated in the German Radiation Protection Ordinance. Regulations refer only to workplaces where the presence of natural radiation leads to a significant increase in the exposure of workers. These workplaces were identified in the following working areas with enhanced exposures to radon-222: underground mines, including visitor mines and show caves; radon-spas and galleries; water supply and distribution industries. Presently, regulations are being initiated by the German government to limit the exposures to radon in homes. For radon measurements at workplaces passive radon devices for individual monitoring as well as active measuring systems for workplace monitoring can be used. However, passive radon devices are preferred for radon measurements in homes because of low costs and availability in large quantities. To assure the quality of radon measurements the German Federal Office for Radiation Protection (BfS) has established annual interlaboratory comparisons for passive radon devices. The comparisons are carried out in the BfS radon calibration laboratory accredited by the German Calibration Service. Passive radon devices which use solid state track detectors, electrets or activated charcoal can be submitted. Approved radon services which offer radon measurements to determine radon exposure in homes and at workplaces have to pass the comparisons successfully. (author)

  17. Metrology of the radon in air volume activity at the italian radon reference chamber

    Energy Technology Data Exchange (ETDEWEB)

    Sciocchetti, G.; Cotellessa, G.; Soldano, E.; Pagliari, M. [Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA Centro Ricerche Casaccia Roma (Italy)

    2006-07-01

    The approach of the Italian National Institute of Ionising Radiations (I.N.M.R.I.-ENEA) on radon metrology has been based on a complete and integrated system which can be used to calibrate the main types of {sup 222}Rn in air measuring instruments with international traceability. The Italian radon reference chamber is a research and calibration facility developed at the Casaccia Research Center in Roma. This facility has an inner volume of one m{sup 3}. The wall is a cylindrical stainless steel vessel coupled with an automated climate apparatus operated both at steady and dynamic conditions. The control and data acquisition equipment is based on Radotron system, developed to automate the multitasking management of different sets of radon monitors and climatic sensors. A novel approach for testing passive radon monitors with an alpha track detector exposure standard has been developed. It is based on the direct measurement of radon exposure with a set of passive integrating monitors based on the new ENEA piston radon exposure meter. This paper describes the methodological approach on radon metrology, the status-of-art of experimental apparatus and the standardization procedures. (authors)

  18. Metrology of the radon in air volume activity at the italian radon reference chamber

    International Nuclear Information System (INIS)

    Sciocchetti, G.; Cotellessa, G.; Soldano, E.; Pagliari, M.

    2006-01-01

    The approach of the Italian National Institute of Ionising Radiations (I.N.M.R.I.-ENEA) on radon metrology has been based on a complete and integrated system which can be used to calibrate the main types of 222 Rn in air measuring instruments with international traceability. The Italian radon reference chamber is a research and calibration facility developed at the Casaccia Research Center in Roma. This facility has an inner volume of one m 3 . The wall is a cylindrical stainless steel vessel coupled with an automated climate apparatus operated both at steady and dynamic conditions. The control and data acquisition equipment is based on Radotron system, developed to automate the multitasking management of different sets of radon monitors and climatic sensors. A novel approach for testing passive radon monitors with an alpha track detector exposure standard has been developed. It is based on the direct measurement of radon exposure with a set of passive integrating monitors based on the new ENEA piston radon exposure meter. This paper describes the methodological approach on radon metrology, the status-of-art of experimental apparatus and the standardization procedures. (authors)

  19. Radon survey in Metropolitan Toronto schools

    International Nuclear Information System (INIS)

    Becker, E.; Moridi, R.

    1992-01-01

    The radon testing survey in Metropolitan Toronto public schools was the most intensive project of its kind ever undertaken in Canadian schools. It also included an extensive public education program on radiation and radon-in-schools. The radon levels at 632 schools were measured using the CAIRS Radon Monitors. Ninety percent of the locations measured were found to have a radon level equal to or less than 2 mWL. Two locations in two different schools were found to have a radon level at or above the Action Level (20 mWL). The remaining results were between the two extremes. Follow-up testing in those schools where more than 10 mWL of radon was found is in progress. (author)

  20. Radon Survey in Hospitals in Slovenia

    International Nuclear Information System (INIS)

    Vaupotic, J.

    2003-01-01

    In Slovenia, several radon studies at workplaces have been carried out in last years, supported by the Ministry of Education, Science and Sport, and the Ministry of Health. After radon surveys in kindergartens, schools and homes, within which about 2600 buildings were checked for radon and which provided the level of radon problem in the country, next investigations were focused on the workplaces with potentially higher radon risk. Hence, in the Postojna Cave permanent radon monitoring was introduced in 1995 and comprehensive radon studies were performed: in 5 bigger spas during 1996-1998, in major waterworks and wine cellars in 2001, and in major Slovene hospitals in 2002. This paper reports the results of radon study in 26 major Slovene hospitals, comprising radon concentrations in 201 rooms and dose estimates for 1025 persons working in these rooms. Radon survey in 201 rooms of 26 major hospitals in Slovenia revealed only 7 rooms in which monthly average radon concentration in the indoor air exceeded 400 Bqm -3 . Generally, concentrations in basement were on average for about 30% higher than in ground floor, although exceptionally high values have also been found in the ground floor. For 966 persons (94.2%) of the total of 1025 persons working in the rooms surveyed, the annual effective dose, estimated according to the Basic Safety Standards was below 1 mSv, while for 59 it exceeded 1 mSv. In 7 rooms with more than 400 Bqm -3 in which 16 persons receive between 2.1 and 7.3 mSv per year radon monitoring is continued. (author)

  1. Radon: Residential attitudes toward the risk

    International Nuclear Information System (INIS)

    Fort, R.; Hinman, G.; Rosenman, R.; Wandschneider, P.

    1990-01-01

    Veradale, Washington (east of Spokane) is a region of high residential radon concentrations. Three hundred eighty residents of Veradale recently responded to a mail survey designed to elicit (1) their knowledge of and attitudes toward the risks of radon in their homes, (2) the actions they have taken or intend to take to identify and reduce those risks, and (3) policy preferences toward radon. Results reveal that these residents know that they live in an area with high radon levels, that radon causes lung cancer, and that radon will affect their health. However only 11% of respondents have had their homes tested for radon. This especially is puzzling because a large number of respondents claimed that (1) radon was important in home buying decisions, (2) they would test their own homes, (3) they would take action if such tests revealed problems, and (4) their willingness to pay for tests and improvements was well within the current costs of these actions. It remains a mystery why testing is at such a low level. Three other results are of note. First, subsidies for radon tests and home improvements may be having the unintended consequences of unneeded improvements and (potentially) moves without improvements. Second, individuals want radon testing required and results made known during home purchase decisions. Third, at present, weatherization programs that concentrate radon are acceptable to individuals. Of course, the future may hold different results. Administrators of weatherization programs, who are trusted by respondents according to this survey, would do well to institute weatherization programs with reduced radon concentrations in mind

  2. ERRICCA radon model intercomparison exercise

    International Nuclear Information System (INIS)

    Andersen, C.E.; Albarracin, D.; Csige, I.; Graaf, E.R. van der; Jiranek, M.; Rehs, B.; Svoboda, Z.; Toro, L.

    1999-04-01

    Numerical models based on finite-difference or finite-element methods are used by various research groups in studies of radon-222 transport through soil and building materials. Applications range from design of radon remediation systems to more fundamental studies of radon transport. To ascertain that results obtained with these models are of good quality, it is necessary that such models are tested. This document reports on a benchmark test organized by the EU project ERRICCA: European Research into Radon in Construction Concerted Action. The test comprises the following cases: 1) Steady-state diffusive radon profiles in dry and wet soils, 2) steady-state entry of soil gas and radon into a house, 3) time-dependent radon exhalation from a building-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive transport of radon, flux calculations, and partitioning of radon between air and water in soil pores. Seven groups participated in the intercomparison. All groups submitted results without knowing the results of others. For these results, relatively large group-to-group discrepancies were observed. Because of this, all groups scrutinized their computations (once more) and engaged in follow-up discussions with others. During this debugging process, problems were indeed identified (and eliminated). The accordingly revised results were in better agreement than those reported initially. Some discrepancies, however, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommended that additional exercises are carried out. (au)

  3. THE REPUBLIC OF BELARUS RADON DANGER MAP

    Directory of Open Access Journals (Sweden)

    L. A. Chunikhin

    2016-01-01

    Full Text Available Radon is the major contributor to the background exposure of the population. In the world practice, the radon risk or radon potential mapping are used for the radon dose assessment.The aim of this work was a radon danger mapping of the Republic of Belarus to assess the radiation situation and determine the radon hazard critical areas.Materials and methods: The mapping is based on measured values of radon volume activity in the living rooms of different buildings on the territory of the six regions of the Republic of Belarus. We have performed more than 4000 measurements. Integral track radon radiometers based on the polymer Kodak LR-115 film were used to evaluate radon volume activity. Exposure time ranged from 90 to 120 days. The cartogram was built with using the MAPINFO software package.Results: The low levels of radon concentrations were determined in the Brest and Gomel regions, as well as in the southern districts of Minsk and south-western districts of the Mogilev region. The high levels radon concentrations were determined in some districts of the Vitebsk and Grodno regions, as well as in the north-eastern districts of the Mogilev region. About 2–5 times nonuniformity of radon distribution in settlements of the Republic was observed. The radon hazard critical areas with radon concentrations in the range of 200–400 Bq/m3 were found in some districts of the Vitebsk, Grodno and Mogilev regions.Conclusions: The radon risk map of the Republic of Belarus gives the possibility to estimate the existing radiation risk. Taking into account the low efficiency of countermeasures long after the Chernobyl accident, it is necessary to increase the level of radiation protection through the radon mitigation activities or to change the radon normative documents.

  4. Indoor radon concentration in Poland

    International Nuclear Information System (INIS)

    Mamont-Ciesla, K.; Jagielak, J.; Rosinski, S.W.; Sosinka, A.; Bysiek, M.; Henschke, J.

    1996-01-01

    Preliminary survey of Rn concentration indoors by means of track detectors and y-ray dose rate with the use of TLD in almost 500 homes in selected areas of Poland was performed in the late 1980s. It was concluded that radon contributes 1.16 mSv i.e. about 46 per cent of the total natural environment ionizing radiation dose to the Polish population. Comparison of the average radon concentrations in 4 seasons of a year and in 3 groups of buildings: masonry, concrete and wood, revealed that the ground beneath the building structure is likely the dominant source of radon indoors. Since the National Atomic Energy Agency in its regulations of 1988-03-31 set up the permissible limit of the equilibrium equivalent concentration of radon in new buildings (equal 100 Bq/m3), the nation-scale survey project for radon in buildings has been undertaken. These regulations were supposed to take effect in 1995-01-01. The project has 3 objectives: to estimate the radiation exposure due to radon daughters received by Polish population to identify radon-prone areas in Poland to investigate dependence of the indoor radon concentrations on such parameters as: type of construction material, presence (or absence) of cellar under the building, number of floor

  5. Airborne geophysical radon hazard mapping

    International Nuclear Information System (INIS)

    Walker, P.

    1993-01-01

    Shales containing uranium pose a radon health hazard even when covered by several meters of overburden. Such an alum shale in southern Norway has been mapped with a joint helicopter borne electromagnetic (HEM) and radiometric survey. Results are compared with ground spectrometer, radon emanometer and radon gas measurements in dwellings, and a model to predict radon gas concentrations from the airborne data is developed. Since the shale is conductive, combining the HEM data with the radiometric channel allows the shale to be mapped with greater reliability than if the radiometric channel were used alone. Radiometrically more active areas which do not pose a radon gas hazard can thus be separated from the shales which do. The ground follow-up work consisted of spectrometer and radon emanometer measurements over a uranium anomaly coinciding with a conductor. The correlation between the airborne uranium channel, the ground uranium channel and emanometry is extremely good, indicating that airborne geophysics can, in this case, be used to predict areas having a high radon potential. Contingency tables comparing both radon exhalation and concentration in dwellings with the airborne uranium data show a strong relationship exists between exhalation and the airborne data and while a relationship between concentration and the airborne data is present, but weaker

  6. Vigilando la Calidad del Agua de los Grandes Rios de la Nacion: El Programa NASQAN del Rio Grande (Rio Bravo del Norte)

    Science.gov (United States)

    Lurry, Dee L.; Reutter, David C.; Wells, Frank C.; Rivera, M.C.; Munoz, A.

    1998-01-01

    La Oficina del Estudio Geologico de los Estados Unidos (U.S. Geological Survey, 0 USGS) ha monitoreado la calidad del agua de la cuenca del Rio Grande (Rio Bravo del Norte) desde 1995 como parte de la rediseiiada Red Nacional para Contabilizar la Calidad del Agua de los Rios (National Stream Quality Accounting Network, o NASOAN) (Hooper and others, 1997). EI programa NASOAN fue diseiiado para caracterizar las concentraciones y el transporte de sedimento y constituyentes quimicos seleccionados, encontrados en los grandes rios de los Estados Unidos - incluyendo el Misisipi, el Colorado y el Columbia, ademas del Rio Grande. En estas cuatro cuencas, el USGS opera actualmente (1998) una red de 40 puntos de muestreo pertenecientes a NASOAN, con un enfasis en cuantificar el flujo en masa (la cantidad de material que pasa por la estacion, expresado en toneladas por dial para cada constituyente. Aplicacando un enfoque consistente, basado en la cuantificacion de flujos en la cuenca del Rio Grande, el programa NASOAN esta generando la informacion necesaria para identificar fuentes regionales de diversos contaminantes, incluyendo sustancias qui micas agricolas y trazas elementos en la cuenca. EI efecto de las grandes reservas en el Rio Grande se puede observar segun los flujos de constituyentes discurren a 10 largo del rio. EI analisis de los flujos de constituyentes a escala de la cuenca proveera los medios para evaluar la influencia de la actividad humana sobre las condiciones de calidad del agua del Rio Grande.

  7. Accurate measurement of indoor radon concentration using a low-effective volume radon monitor

    International Nuclear Information System (INIS)

    Tanaka, Aya; Minami, Nodoka; Mukai, Takahiro; Yasuoka, Yumi; Iimoto, Takeshi; Omori, Yasutaka; Nagahama, Hiroyuki; Muto, Jun

    2017-01-01

    AlphaGUARD is a low-effective volume detector and one of the most popular portable radon monitors which is currently available. This study investigated whether AlphaGUARD can accurately measure the variable indoor radon levels. The consistency of the radon-concentration data obtained by AlphaGUARD is evaluated against simultaneous measurements by two other monitors (each ∼10 times more sensitive than AlphaGUARD). When accurately measuring radon concentration with AlphaGUARD, we found that the net counts of the AlphaGUARD were required of at least 500 counts, <25% of the relative percent difference. AlphaGUARD can provide accurate measurements of radon concentration for the world average level (∼50 Bq m -3 ) and the reference level of workplace (1000 Bq m -3 ), using integrated data over at least 3 h and 10 min, respectively. (authors)

  8. Instrumentation for a radon research house

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Revzan, K.L.; Robb, A.W.

    1981-07-01

    A highly automated monitoring and control system for studying radon and radon-daughter behavior in residences has been designed and built. The system has been installed in a research house, a test space contained in a two-story wood-framed building, which allows us to conduct controlled studies of (1) pollutant transport within and between rooms, (2) the dynamics of radon daughter behavior, and (3) techniques for controlling radon and radon daughters. The system's instrumentation is capable of measuring air-exchange rate, four-point radon concentration, individual radon daughter concentrations, indoor temerature and humidity, and outdoor weather parameters (temperature, humidity, modules, wind speed, and wind direction). It is also equipped with modules that control the injection of radon and tracer gas into the test space, the operation of the forced-air furnace, the mechanical ventilation system, and the mixing fans located in each room. A microcomputer controls the experiments and records the data on magnetic tape and on a printing terminal. The data on tape is transferred to a larger computer system for reduction and analysis. In this paper we describe the essential design and function of the instrumentation system, as a whole, singling out those components that measure ventilation rate, radon concentration, and radon daughter concentrations

  9. Contribution of waterborne radon to home air quality

    International Nuclear Information System (INIS)

    Deb, A.K.

    1994-01-01

    Radon-222 is a member of the uranium decay chain and is formed from the decay of radium-226. Radon and its decay products emit alpha particles during the decay process. If radon is inhaled, alpha particles emitted from inhaled radon and its daughters increase the risk of lung cancer. Radon is soluble in water; thus when radon comes in contact with groundwater it dissolves. The radon concentration in groundwater may range from 100 pCi/L to 1,000,000 pCi/L. When water with a high radon level is used in the home, radon is released from the water to the air and thus can increase indoor air radon concentration. Considering the estimated health risk from radon in public water supply systems, EPA has proposed a maximum contaminant level (MCL) of 300 pCi/L for radon in public drinking water supplies. To address the health risks of radon in water and the proposed regulations, the American Water Works Association Research Foundation (AWWARF) initiated a study to determine the contribution of waterborne radon to radon levels in indoor household air

  10. Radon in Croatian spas

    International Nuclear Information System (INIS)

    Radolic, V.; Vukovic, B.; Planinic, J.

    2004-01-01

    There are ten thermal spas in Croatia and all of them provide health services for patients and visitors. Radon measurements were performed since there is a lack of data concerning natural radioactivity originated from radon and its short-lived progenies in such environments. The thermal water at two different sites (the indoor swimming pool with geothermal water and the spring) in each spa was sampled and radon concentrations were measured by AlphaGUARD radon measuring system. The obtained values were in the range of 0.7 to 19 Bq.dm -3 and 2 to 94 Bq.dm -3 for indoor swimming pools and springs, respectively. Integrated measurements of radon concentration in air were performed by two solid state nuclear track detectors LR-115 II (open and diffusion one) thus enabling estimation of equilibrium factor between radon and its daughters. The annual effective doses received by spa workers were found to be about 1 mSv/y (below the lower limit value of 3 mSv/y recommended by ICRP 65). The doses of patients and visitors were one or two order of magnitude lower than that of the personnel. (author)

  11. Hidrogeoquímica y procesos naturales de ablandamiento del agua subterránea en sistemas kársticos

    OpenAIRE

    Luvina Bibiano

    2015-01-01

    Bibiano, L., Gárfias, J., & Llanos, H. (mayo-junio, 2015). Hidrogeoquímica y procesos naturales de ablandamiento del agua subterránea en sistemas kársticos. Tecnología y Ciencias del Agua, 6(3), 57-78.El agua que emerge de los manantiales kársticos contiene altas concentraciones de dureza total causadas por la disolución de formaciones geológicas carbonatadas, lo cual limita el uso doméstico e industrial del recurso en estas zonas. El enfoque aplicado con...

  12. Chemical properties of radon

    International Nuclear Information System (INIS)

    Stein, L.

    1986-01-01

    Radon is frequently regarded as a totally inert element. It is, however, a ''metalloid'' - an element which lies on the diagonal of the Periodic Table between the true metals and nonmetals and which exhibits some of the characteristics of both. It reacts with fluorine, halogen fluorides, dioxygenyl salts, fluoro-nitrogen salts, and halogen fluoride-metal fluoride complexes to form ionic compounds. Several of the solid reagents can be used to collect radon from air but must be protected from moisture, since they hydrolyze readily. Recently, solutions of nonvolatile, cationic radon have been produced in nonaqueous solvents. Ion-exchange studies have shown that the radon can be quantitatively collected on columns packed with either Nafion resins or complex salts. In its ionic state, radon is able to displace H + , Na + , K + , Cs + , Ca 2+ , and Ba 2+ ions from a number of solid materials. 27 refs., 6 figs

  13. The radon: evaluation and risk management; Le radon: evaluation et gestion du risque

    Energy Technology Data Exchange (ETDEWEB)

    Lacoste, A.C. [Direction Generale de la Surete Nucleaire et de la Radioprotection, 75 - Paris (France); Masse, R. [Academie des Technologies, 75 - Paris (France); Aurengo, A. [Hopital Pitie-Salpetriere, Service de Medecine Nucleaire, 75 - Paris (France); Erich Wichmann, H. [Neuberberg Munich Univ. (Germany); Timarche, M.; Laurier, D.; Robe, M.Ch. [Institut de Radioprotection et de Surete Nucleaire (IRSN), 92 - Clamart (France); Baubron, J.C.; Bonijoly, D. [BRGM, 75 - Paris (France); Collignan, B. [Centre Scientifique et Technique du Batiment, (CSTB), 75 - Paris (France); Berrier, H. [Direction Gle de l' Urbanisme de l' Habitat et de la Construction, 75 - Paris (France); Jaouen, J. [Direction Departementale des Affaires Sanitaires et Sociales de la Haute-Vienne (France); Caamano, D. [Direction Departementale des Affaires Sanitaires et Sociales de l' Essonne, 91 (France); Guiot, F. [Direction Departementale des Affaires Sanitaires et Sociales de la Haute-Marne (France); Grall, B. [Direction Departementale des Affaires Sanitaires et Sociales de Bretagne (France); Frutos Vasquez, B.; Olaya Adan, M. [Istituto de Ciencias de la Construction (Italy); Garcia Cadierno, J.P.; Martin Matarranz, J.L.; Serrano Renedo, J.; Suarez Mahou, E. [Consejo de Seguridad Nuclear, Madrid (Spain); Fernandez, J.A. [ENUSA Industrias Avanzadas (Spain); Mjones, L.; Pirard, P. [Institut de veille sanitaire, 94415 - Saint-Maurice (France); Godet, J.L.; Rougy, Ch. [Direction Gle de la Surete Nucleaire et de la Radioprotection, 75 - Paris (France)

    2003-06-15

    The radon exposure constitutes for the French population the first cause of natural irradiation among the different natural sources of irradiation. It is possible to have a significant action on it, either by making draught proof in order to avoid to radon to get inside houses, either by ventilating in order to dispel the radon and improve air quality. (N.C.)

  14. Radon in large buildings

    International Nuclear Information System (INIS)

    Wilson, D.L.; Dudney, C.S.; Gammage, R.B.

    1993-01-01

    Over the past several years, considerable research has been devoted by the U.S. Environmental Protection Agency (USEPA) and others to develop radon sampling protocols for single family residences and schools. However, very little research has been performed on measuring radon in the work place. To evaluate possible sampling protocols, 833 buildings throughout the United States were selected for extensive radon testing. The buildings tested (warehouses, production plants and office buildings) were representative of commercial buildings across the country both in design, size and use. Based on the results, preliminary radon sampling protocols for the work place have been developed. (orig.). (5 refs., 3 figs.)

  15. Radon dose and aerosols

    International Nuclear Information System (INIS)

    Planinic, J.; Radolic, V.; Faj, Z.; Vukovic, B.

    2000-01-01

    The equilibrium factor value (F) was measured in the NRPB radon chamber and the corresponding track density ratio (r = D/D 0 ) of bare (D) and diffusion (D 0 ) LR-115 nuclear track detectors was determined, as well as the regression equation F(r). Experiments with LR-115 nuclear track detectors and aerosol sources (burning candle and cigarette) were carried out in the Osijek University radon chamber and afterwards an empirical relationship between the equilibrium factor and aerosol concentration was derived. For the purpose of radon dose equivalent assessment, procedures for determining the unattached fraction of radon progeny were introduced using two nuclear track detectors. (author)

  16. Radon remediation of a two-storey UK dwelling by active sub-slab depressurization: observations on hourly Radon concentration variations

    International Nuclear Information System (INIS)

    Denman, A.R.

    2008-01-01

    Radon concentration levels in a two-storey detached single-family dwelling in Northamptonshire, UK, were monitored at hourly intervals throughout a 5-week period during which sub-slab depressurization remediation measures, including an active sump system, were installed. Remediation of the property was accomplished successfully, with the mean radon levels upstairs and downstairs greatly reduced and the prominent diurnal variability in radon levels present prior to remediation almost completely removed. Following remediation, upstairs and downstairs radon concentrations were 32% and 16% of their pre-remediation values respectively. The mean downstairs radon concentration was lower than that upstairs, with pre-and post-remediation values of the upstairs/downstairs concentration ratio, R U/D , of 0.93 and 1.76 respectively. Cross-correlation between upstairs and downstairs radon concentration time-series indicates a time-lag of the order of 1 hour or less, suggesting that diffusion of soil-derived radon from downstairs to upstairs either occurs within that time frame or forms a relatively insignificant contribution to the upstairs radon level. Cross-correlation between radon concentration time-series and the corresponding time-series for local atmospheric parameters demonstrated correlation between radon concentrations and internal/external pressure-difference prior to remediation. This correlation disappears following remediation, confirming the effectiveness of the remediation procedure in mitigating radon ingress from the ground via the stack-effect. Overall, these observations provide further evidence that radon emanation from building materials makes a not insignificant contribution to radon concentration levels within the building. Furthermore, since this component remains essentially unaffected by sub-slab depressurization, its proportional contribution to the total radon levels in the home increases following remediation, leading to the conclusion that where

  17. Contribution of radon in natural gas to the dose from aiborne radon-daughters in homes

    International Nuclear Information System (INIS)

    Barton, C.J.; Moore, R.E.; Rohwer, P.S.

    1973-01-01

    Data have been obtained on the radon concentration in natural gas supplied to several metropolitan areas in the United States. The average value of 20 pCi/l was selected to estimate the contribution of this source of natural radioactivity to doses from radon-daughters received by individuals in homes. Radon-daughter concentrations in the home atmosphere were calculated by use of computer programs for an 8000 ft 3 house in which 27 ft 3 of gas per day was used for cooking in an unvented kitchen range. The total estimated dose to the bronchial epithelium included contributions from radon plus daughters in the outside ventilation air, each of which was assumed to be present at a concentration of 0.13 pCi/l, and from the radon plus daughters in the natural gas. The latter contribution averaged approximately 3 percent of the total dose. There was a 3.5 percent decrease in the estimated total dose when the air change rate increased from 0.25 to 2.0 per hour. We conclude that radon and radon-daughters entering the home with natural gas produce a negligible fraction of the total dose to the respiratory system of home occupants from airborne radon-daughters

  18. Radon and radon-daughter concentrations in air in the vicinity of the Anaconda Uranium Mill

    Energy Technology Data Exchange (ETDEWEB)

    Momeni, M H; Lindstrom, J B; Dungey, C E; Kisieleski, W E

    1979-11-01

    Radon concentration, working level, and meteorological variables were measured continuously from June 1977 through June 1978 at three stations in the vicinity of the Anaconda Uranium Mill with measurements integrated to hourly intervals. Both radon and daughters show strong variations associated with low wind velocities and stable atmospheric conditions, and diurnal variations associated with thermal inversions. Average radon concentration shows seasonal dependence with highest concentrations observed during fall and winter. Comparison of radon concentrations and working levels between three stations shows strong dependence on wind direction and velocity. Radon concentrations and working-level distributions for each month and each station were analyzed. The average maximum, minimum, and modal concentration and working levels were estimated with observed frequencies. The highest concentration is 11,000 pCi/m/sup 3/ on the tailings. Working-level variations parallel radon variations but lag by less than one hour. The highest working levels were observed at night when conditions of higher secular radioactive equilibrium for radon daughters exist. Background radon concentration was measured at two stations, each located about 25 km from the mill, and the average is 408 pCi/m/sup 3/. Average working-level background is 3.6 x 10/sup -3/.

  19. An investigation into the knowledge and attitudes towards radon testing among residents in a high radon area

    International Nuclear Information System (INIS)

    Clifford, Susan; Menezes, Gerard; Hevey, David

    2012-01-01

    The aim of this study was to investigate the knowledge and attitudes of residents in the Castleisland area to radon. Castleisland in Co. Kerry was described as a high radon area following the discovery of a house in the area with radon levels 245 times that of the national reference level. Residents in this area were then asked to measure their homes for radon in the Castleisland radon survey. The uptake of this measurement was 17%. In order to investigate this response rate further, a questionnaire was designed and distributed to residents in the Castleisland area. This questionnaire measured the testing history of the participants, the reasons for testing/not testing, the factors important to them when considering having their home tested, radon knowledge and finally intentions to measure their home for radon. It was found that the main reason people do not test their home for radon is that they believe their home does not have a problem. Optimistic bias was thought to play a role here. The subjective norm component of the theory of planned behaviour was found to have a significant independent contribution in the variation in intentions to measure one’s home for radon and this in turn could be targeted to increase uptake of radon measurement in the future. (note)

  20. Radon in dwellings the national radon survey Clare, Limerick and Tipperary

    International Nuclear Information System (INIS)

    McGarry, A.T.; Fennell, S.G.; Mackin, G.M.; Madden, J.S.; O'Colmain, M.

    1998-12-01

    This report presents the results of the fourth phase of the National Radon Survey carried out by the Radiological Protection Institute of Ireland. The counties included in this phase are Clare, Limerick and Tipperary. The average radon concentrations for the houses measured in these counties were 88 Bq/m 3 , 77 Bq/m 3 and 79 Bq/m 3 . The measurement data were grouped on the basis of the 10 km grid squares of the Irish National Grid System and used to predict the percentage of dwellings in each grid square which exceeds the Reference Level of 200 Bq/m 3 . Grid squares where this percentage is predicted to be 10% or higher are designated High Radon Areas. The health effects of exposure to high radon levels are discussed and recommendations are made regarding both new and existing dwellings. (author)

  1. Environmental Concentration of Radon and Radon Progeny in a Nuclear Facility in a Decommissioning Stage

    International Nuclear Information System (INIS)

    Ramirez, M. P.; Correa, E.; Sancho, C.

    1999-01-01

    According to the new European Directive 96/29/EURATOM the radiological risk due to natural radionuclides must be consider and the pertinent periodic control must be realized. During the works performed at CIEMAT an estimation of the effective average doses due to Radon inhalation in work places of the installation have been performed. Radon and Radon progeny concentration has been measured in continuous joint whit the meteorological conditions as temperature, pressure and relative humidity. Two different equipment has been used: Alpha-guard whit ionization chamber detector and Eda-wlm-300 whit a semiconductor detector. A passive Radon detector, E-perm has been simultaneously used in the monitoring system. The results obtained during the measuring of Radon and Radon progeny concentrations indoors and estimation of doses have been analyzed and are presented in the paper. (Author) 11 refs

  2. Radon remediation in irish schools

    International Nuclear Information System (INIS)

    Synnott, H.

    2006-01-01

    Full text: Commencing in 1998, the Radiological Protection Institute of Ireland carried out radon measurements in 3826 schools in the Republic of I reland on behalf of the Irish Department of Education and Science (D.E.S.). This represents approximately 97% of all schools in the country. Approximately 25% (984) schools had radon concentrations above the Irish national schools Reference Level for radon of 200 Bq/m 3 and required remedial work. The number of individual rooms with radon concentrations above 200 Bq/m 3 was 3020. Remedial work in schools commenced in early 2000. In general schools with maximum radon concentrations in the range 200 -400 Bq/m 3 in one or more rooms were remediated through the installation of passive systems such as an increase in permanent background ventilation mainly wall vents and trickle vents in windows. Schools with maximum radon concentrations greater than 400 Bq/m 3 were usually remediated through the provision of active systems mainly fan assisted sub -slab de pressurization or where this was not possible fan assisted under floor ventilation. The cost of the remedial programme was funded by central Government. Active systems were installed by specialized remedial contractors working to the specifications of a radon remedial expert appointed by the D.E.S. to design remedial systems for affected schools. Schools requiring increased ventilation were granted aided 190 pounds per affected room and had to organize the work themselves. In most schools radon remediation was successful in reducing existing radon concentrations to below the Reference Level. Average radon concentration reduction factors for sub-slab de pressurization systems and fan assisted fan assisted under floor ventilation ranged from 5 to 40 with greater reduction rates found at higher original radon concentrations. Increasing ventilation in locations with moderately elevated radon concentrations (200 - 400 Bq/m 3 ) while not as effective as active systems produced on

  3. Determinación de metilmercurio en cabello del recién nacido como evaluación de exposición gestacional

    Directory of Open Access Journals (Sweden)

    F. Lozano-Kasten

    2015-01-01

    Conclusiones: El cabello del recién nacido es una fuente más de información para obtener datos de concentraciones de mercurio en cabello, y de interés para estudiar la carga de morbilidad ambiental por metilmercurio.

  4. Radon risk communication research: Practical lessons

    International Nuclear Information System (INIS)

    Fisher, A.; Johnson, F.R.

    1990-01-01

    Those responsible for state and local radon programs often express frustration about the small share of homes that have been tested for radon, and the small share of those with high readings that have been mitigated. There are now a number of completed studies that have examined how well alternative ways of communicating about radon risk have accomplished the goals of motivating appropriate testing and mitigation. This paper summarizes the research results that are most crucial for planning and implementing effective radon risk communication programs. We identify six reasons why people do not respond to radon as a serious threat and provide some remedies suggested by radon studies

  5. ANÁLISIS DEL ESTADO NUTRIMENTAL DEL CULTIVO DE LA PAPA EN COSTA RICA CON BASE EN INFORMACIÓN EXISTENTE

    Directory of Open Access Journals (Sweden)

    Róger Fallas

    2014-01-01

    Full Text Available Se realizó un análisis de los resultados de análisis foliares del cultivo de la papa, procesados en el Laboratorio de Suelos y Foliares del Centro de Investigaciones Agronómicas de la Universi - dad de Costa Rica (LSF-CIA/UCR durante el 2006 al 2012. También, mediante diferentes fuen - tes de la literatura, se recopilaron los niveles crí - ticos foliares (NC establecidos para el cultivo de la papa en diferentes regiones del mundo. Con esa información, se comparó el porcentaje de mues - tras analizadas en Costa Rica que se encontraban por debajo de los niveles críticos reportados. Se encontraron concentraciones por debajo del nivel crítico, en una gran cantidad de muestras, para los elementos B, Ca y Mg, según el criterio de NC utilizado en la interpretación de los resultados (mínimo o promedio de la literatura.

  6. Radon classification of building ground

    International Nuclear Information System (INIS)

    Slunga, E.

    1988-01-01

    The Laboratories of Building Technology and Soil Mechanics and Foundation Engineering at the Helsinki University of Technology in cooperation with The Ministry of the Environment have proposed a radon classification for building ground. The proposed classification is based on the radon concentration in soil pores and on the permeability of the foundation soil. The classification includes four radon classes: negligible, normal, high and very high. Depending on the radon class the radon-technical solution for structures is chosen. It is proposed that the classification be done in general terms in connection with the site investigations for the planning of land use and in more detail in connection with the site investigations for an individual house. (author)

  7. Ground-truthing predicted indoor radon concentrations by using soil-gas radon measurements

    International Nuclear Information System (INIS)

    Reimer, G.M.

    2001-01-01

    Predicting indoor radon potential has gained in importance even as the national radon programs began to wane. A cooperative study to produce radon potential maps was conducted by the Environmental Protection Agency (EPA), U.S. Geological Survey (USGS), Department of Energy (DOE), and Lawrence Berkeley Laboratory (LBL) with the latter taking the lead role. A county-wide predictive model based dominantly on the National Uranium Resource Evaluation (NURE) aerorad data and secondly on geology, both small-scale data bases was developed. However, that model breaks down in counties of complex geology and does not provide a means to evaluate the potential of an individual home or building site. Soil-gas radon measurements on a large scale are currently shown to provide information for estimating radon potential at individual sites sort out the complex geology so that the small-scale prediction index can be validated. An example from Frederick County, Maryland indicates a positive correlation between indoor measurements and soil-gas data. The method does not rely on a single measurement, but a series that incorporate seasonal and meteorological considerations. (author)

  8. Investigation of radon level in Chongqing

    International Nuclear Information System (INIS)

    Pan Chunzhen; Liu Jialie; Du Hengyan; Wang Ling; Li Yiwei

    2009-01-01

    Contents of radon in air in the urban district, building fields,diggings and hotel in Chongqing were investigated. Result shows that the mean concentration of radon is 10.8 Bq/m 3 in air in the urban district, and the mean concentration of radon is 1193 Bq/m 3 in soils on building fields. Radon level is obviously different in each of diggings, with the highest being in fluorite mine and the second in plumbum and zinc mine. The statistical mean value of radon concentration of 10 typles of diggings investigated is 65.2 Bq/m 3 , while the mean concentration of radon in fluorite mine is 369 Bq/m 3 , which is 35 times higher than in the urban area. The mean concentration of radon is 32.9 Bq/m 3 in eight hotels. (authors)

  9. Paloma-radon: atmospheric radon 222 as a geochemical probe for water in the martian subsoil

    International Nuclear Information System (INIS)

    Sabroux, J.Ch.; Michielsen, N.; Voisin, V.

    2003-01-01

    Radon exhalation from a porous soil is known to depend strongly on the soil moisture content: a minute amount of water, or water ice, in the pore space increases dramatically the possibility for radon to migrate far from its parent mineral. We propose to take advantage of this characteristic by using atmospheric radon 222 as a geochemical probe for water in the Martian soil, at least one order of magnitude deeper than the current Mars Odyssey neutron data. Strong thermal inversions during the Martian night will accumulate radon in the lowest atmospheric boundary layer, up to measurable levels despite the comparatively high environmental (cosmic and solar) background radiation and the assumed low uranium content of the upper crust of the planet. Preliminary studies and development of an instrument for the measurement of the Martian atmospheric alpha radioactivity is part of the CNES supported PALOMA experiment. Two test benches have been implemented, one of them allowing differential measurements of the diffusion of radon in the Martian soil simulant NASA JSC Mars-1, under relevant temperatures and pressures. The other, a 1 m3 radon-dedicated test bench, aims to characterize the instrument that will measure radon in the Mars environment (7 mb CO 2 ). Tests on several nuclear radiation detectors show that semiconductor alpha-particle detectors (PIPS) are the best option. In addition, the detection volume is left open in order to capitalize upon the long (ca. 4 m) alpha track at this low pressure. A stationary diffusion model was developed in order to assess the radon flux at the Mars soil surface. Diffusion of gas in Martian soil is governed by Knudsen diffusion. The radon Knudsen diffusion coefficient was estimated, depending on the soil moisture and relevant structural properties, leading to a radon diffusion length of the order of 20 m. The landed platform PALOMA-Radon instrument will consist of a set of alpha detectors connected to an electronic spectrometer, a

  10. Paloma-radon: atmospheric radon 222 as a geochemical probe for water in the martian subsoil

    Energy Technology Data Exchange (ETDEWEB)

    Sabroux, J.Ch.; Michielsen, N.; Voisin, V

    2003-07-01

    Radon exhalation from a porous soil is known to depend strongly on the soil moisture content: a minute amount of water, or water ice, in the pore space increases dramatically the possibility for radon to migrate far from its parent mineral. We propose to take advantage of this characteristic by using atmospheric radon 222 as a geochemical probe for water in the Martian soil, at least one order of magnitude deeper than the current Mars Odyssey neutron data. Strong thermal inversions during the Martian night will accumulate radon in the lowest atmospheric boundary layer, up to measurable levels despite the comparatively high environmental (cosmic and solar) background radiation and the assumed low uranium content of the upper crust of the planet. Preliminary studies and development of an instrument for the measurement of the Martian atmospheric alpha radioactivity is part of the CNES supported PALOMA experiment. Two test benches have been implemented, one of them allowing differential measurements of the diffusion of radon in the Martian soil simulant NASA JSC Mars-1, under relevant temperatures and pressures. The other, a 1 m3 radon-dedicated test bench, aims to characterize the instrument that will measure radon in the Mars environment (7 mb CO{sub 2}). Tests on several nuclear radiation detectors show that semiconductor alpha-particle detectors (PIPS) are the best option. In addition, the detection volume is left open in order to capitalize upon the long (ca. 4 m) alpha track at this low pressure. A stationary diffusion model was developed in order to assess the radon flux at the Mars soil surface. Diffusion of gas in Martian soil is governed by Knudsen diffusion. The radon Knudsen diffusion coefficient was estimated, depending on the soil moisture and relevant structural properties, leading to a radon diffusion length of the order of 20 m. The landed platform PALOMA-Radon instrument will consist of a set of alpha detectors connected to an electronic spectrometer

  11. Radon Concentration in Caves of Croatia - Assesing Effective Radon Doses for Occupational Workers and Visitors

    International Nuclear Information System (INIS)

    Radolic, V.; Miklavcic, I.; Poje, M.; Stanic, D.; Vukovic, B.; Paar, D.

    2011-01-01

    Radon monitoring at potentially highly radioactive location such as caves is important to assess the radiological hazards to occupational workers and occasional visitors. In its Publication 65 the ICRP has produced recommendations dealing with exposure to elevated background radiation, in particular, the risk associated with the inhalation of radon and radon progeny. Recommended annual effective dose from radon 222Rn and its short-lived progeny for workers should not exceed 20 mSv and for occasional users (visitors) the same recommendation is 1 mSv. Measurements were performed with series of track etched detectors (LR115 - type II) in several caves in Croatia. The obtained values for the radon concentration ranged from ambient values up to several thousand Bq m -3 . Radon concentration was measured in about 20 caves of Velebit and Zumberak mountains and the highest radon concentration was in Lubuska jama (3.8 kBq m -3 ) and cave Dolaca (21.8 kBq m -3 ), respectively. Djurovica cave is especially interesting because of its huge tourist potential due to its location bellow Dubrovnik airport. Its mean annual radon concentration of 17.6 kBq m -3 classifies Djurovica cave among caves with high radon concentration. A visitor during half an hour visit at summer time would receive an effective dose of 30.6 μSv. Calculated mean dose rate of 44 μSv/h means that workers (mainly tourist guides) should limit their time inside cave to 454 hours per year. Manita pec is the only cave open for tourists on the territory of Paklenica National Park. The preliminary radon measurements performed during summer 2010, gave an average radon concentration of 1.1 kBq m -3 . An exposure to average dose rate of 3.7 μSv/h means that the tourist guides would receive an effective dose of 0.42 mSv during summer period according to their working schedule. A visitor during half an hour visits would receive an effective dose of 1.86 μSv. (author)

  12. Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration

    International Nuclear Information System (INIS)

    Yanliang Tan; Detao Xiao

    2013-01-01

    The paper will present a method based on the accumulation chamber technique for measuring of radon exhalation from the medium surface. A radon monitor traces the change of radon concentration in the accumulation chamber, and then the radon exhalation can be obtained accurately through linear fit. Based on our recent experiments, the radon exhalation rate from the medium surface obtained from this method is in good agreement with the actual exhalation rate of our simulation facility. This method is superior to the competition method which obtains the radon exhalation through the exponential fit by an external PC-system. The calculation for the exponential fit is very easy by computer and related software. However, for portable instruments, the single chip microcomputer can't calculate the exponential fit rapidly. Thus, this method is usable for developing the new portable instrument to classify building materials, etc. (author)

  13. Radon emanometry in active volcanoes

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, J.L.; Monnin, M. (CNRS, IN2P3, BP45/F63170 Aubiere (France)); Cejudo, J. (Instituto Nacional de Investigaciones Nucleares, Mexico City)

    1984-01-01

    Radon emission measurements from active volcanoes has, since 1981, been continuously measured at monitoring stations in Mexico and in Costa Rica. Counting of etched alpha tracks on cellulose nitrate LR-115 detectors give varying results at the several stations. Radon emanation at Chichon, where an explosive eruption occurred in 1982, fell down. Radon detection at the active volcano in Colima shows a pattern of very low emission. At the Costa Rica stations located at Poas, Arenal and Irazu, the radon emanation shows regularity.

  14. Radon risk in residential buildings

    International Nuclear Information System (INIS)

    Niewiadomski, T.

    1996-01-01

    The author discusses the risk related to the inhalation of radon decay products. This products are the cause of almost the half of the doses absorbed by the people. The concentration of radon in buildings is much higher than in the open areas and its country average in Poland is 50 Bq/m 3 . It is difficult to predict the concentration of radon in the building without measurement. Author concludes that there are technical means to decrease radon concentration in buildings

  15. An investigation of radon mitigation in Pennsylvania

    International Nuclear Information System (INIS)

    Belanger, W.E.

    1990-01-01

    This paper reports that Radon mitigation contractors were contacted to obtain information on the progress of radon mitigation in Pennsylvania. Information was obtained on the beginning and ending radon concentrations, the cost of the job, the mitigation method used, and the location by zip code. Most radon mitigations achieved reductions below 90 percent, and most achieved 4 pCi/1. 65 percent achieved 2 pCi/1. There was little relationship between the cost of the job and either the percent reduction or the beginning radon. Percent reduction was strongly related to beginning radon, with lower percent reductions associated with low starting radon

  16. Effect of natural ventilation on radon and radon progeny levels in houses. Rept. for Apr 90-Sep 91

    International Nuclear Information System (INIS)

    Cavallo, A.; Gadsby, K.; Reddy, T.A.; Socolow, R.

    1991-01-01

    The paper discusses the effect of natural ventilation on radon and radon progeny levels in houses. Contradicting the widely held assumption that ventilation is ineffective in reducing indoor radon concentrations, experiments in a research house have shown that the basement radon level can be reduced by a factor of 5 to 10 using only natural ventilation. Measurement of the outdoor-basement pressure differential and the radon entry rate shows that this unexpectedly large reduction in indoor radon levels is caused by two complementary physical processes: (1) the obvious one, dilution, which lowers radon concentrations by adding uncontaminated outdoor air; and (2) although less evident, introducing a pressure break in the system through an open basement window which, in turn, reduces the outdoor-basement pressure differential and the rate at which radon-laden soil gas is drawn into the house. The radon entry rate was found to be a linear function of basement depressurization up to a differential pressure of about 4 Pa, as would be expected for laminar soil gas flow; opening two basement windows approximately doubled the building air exchange rate and reduced the radon entry rate by up to a factor of 5

  17. A perspective on risks from radon

    International Nuclear Information System (INIS)

    Higson, D. J.

    2010-10-01

    In its Statement on Radon (November 2009), the International Commission on Radiological Protection (ICRP) has reduced the upper reference level for radon gas in dwellings to 300 Bq m -3 . The recommended level for workplaces is 1000 Bq m -3 . A risk coefficient of 8 x 10 -10 per Bq h m -3 is recommended without reference to smoking habits. On the basis of these figures: 1) The estimated risk of fatal cancer from exposure to radon at home and at work could be greater than the observed risk of accidental death from travelling by car, which would be surprising if true. 2) The estimated risk of lung cancer from radon could be greater than the observed risk of lung cancer from all causes, which is actually known to be dominated by smoking. The author is not aware of any direct evidence of risks from inhaling radon in Australian dwellings, 99% of which have radon levels below 50 Bq m -3 . Evidence available from other countries shows that: 1) The effects of radon in the incidences of lung cancer are uncertain at levels less then about 50-100 Bq m -3 . 2) The estimation of risks at levels below 200 Bq m -3 depends on extrapolation from risks observed at higher levels. 3) Risks to non-smokers from radon are 25 times less than risks to smokers. Its concluded that the ICRP Statement on Radon and radon policies in the US and UK have the potential to cause unwarranted concern. Some people may be made to feel they need to spend money modifying their homes and workplaces to protect occupants from exposure to radon when there is no compelling reason to show that this is necessary. The vast majority of non-smokers do not need to be protected from radon. (Author)

  18. A perspective on risks from radon

    International Nuclear Information System (INIS)

    Higson, D.J.

    2011-01-01

    In its Statement on Radon (November 2009), the ICRP has reduced the upper reference level for radon gas in dwellings to 300 Bq m -3 . The recommended level for workplaces is 1000 Bq m -3 . A risk coefficient of 8x10 -10 per Bq h m is recommended without reference to smoking habits. On the basis of these figures,the estimated risk of fatal cancer from exposure to radon at home and at work could be greater than the observed risk of accidental death from travelling by car, which would be surprising if true. Also the estimated risk of lung cancer from radon could be greater than the observed risk of lung cancer from all causes, which is actually known to be dominated by smoking. The author is not aware of any direct evidence of risks from inhaling radon in Australian dwellings, 99% of which have radon levels below 50 Bq m -3 . Evidence available from other countries shows that: effects on the incidences of lung cancer are uncertain at radon levels below 100 Bq m -3 ; the estimation of risks at levels below 200 Bq m -3 depends on extrapolation from risks observed at higher levels, and risks to non-smokers from radon are 25 times less than risks to smokers. It is concluded that the ICRP Statement on Radon and radon policies in the US and UK have the potential to cause unwarranted concern. Some people may be made to feel they need to spend money modifying their homes and workplaces to protect occupants from exposure to radon when there is no compelling reason to show that this is necessary. The vast majority of non-smokers do not need to be protected from radon.

  19. A perspective on risks from radon

    Energy Technology Data Exchange (ETDEWEB)

    Higson, D. J., E-mail: higsond@bigpond.net.a [Australasian Radiation Protection Society, PO Box 7108, Upper Ferntree Gully, Victoria 3156 (Australia)

    2010-10-15

    In its Statement on Radon (November 2009), the International Commission on Radiological Protection (ICRP) has reduced the upper reference level for radon gas in dwellings to 300 Bq m{sup -3}. The recommended level for workplaces is 1000 Bq m{sup -3}. A risk coefficient of 8 x 10{sup -10} per Bq h m{sup -3} is recommended without reference to smoking habits. On the basis of these figures: 1) The estimated risk of fatal cancer from exposure to radon at home and at work could be greater than the observed risk of accidental death from travelling by car, which would be surprising if true. 2) The estimated risk of lung cancer from radon could be greater than the observed risk of lung cancer from all causes, which is actually known to be dominated by smoking. The author is not aware of any direct evidence of risks from inhaling radon in Australian dwellings, 99% of which have radon levels below 50 Bq m{sup -3}. Evidence available from other countries shows that: 1) The effects of radon in the incidences of lung cancer are uncertain at levels less then about 50-100 Bq m{sup -3}. 2) The estimation of risks at levels below 200 Bq m{sup -3} depends on extrapolation from risks observed at higher levels. 3) Risks to non-smokers from radon are 25 times less than risks to smokers. Its concluded that the ICRP Statement on Radon and radon policies in the US and UK have the potential to cause unwarranted concern. Some people may be made to feel they need to spend money modifying their homes and workplaces to protect occupants from exposure to radon when there is no compelling reason to show that this is necessary. The vast majority of non-smokers do not need to be protected from radon. (Author)

  20. Concentraciones de compuestos tóxicos persistentes en la población española: el rompecabezas sin piezas y la protección de la salud pública

    Directory of Open Access Journals (Sweden)

    Porta M.

    2002-01-01

    Full Text Available La contaminación por compuestos tóxicos persistentes (CTP de la población general es un hecho relevante desde una perspectiva de salud pública. Es, asimismo, importante para el sistema sanitario asistencial y para las políticas ambientales, alimentarias, industriales y económicas. Aunque en España los conocimientos sobre la contaminación de los alimentos por CTP presentan grandes vacíos temporales y geográficos, aún es menor la información sobre sus concentraciones en las personas: no existe ningún estudio representativo de una población general sana efectuado en una zona geográfica amplia. Los estudios disponibles indican que un 80-100% de la población tiene concentraciones detectables de DDE, policlorobifenilos, hexaclorobenceno o lindano. En España el número de estudios sobre los efectos que los CTP tienen en las personas es todavía más exiguo. Los estudios internacionales sugieren que dosis de algunos CTP por debajo de las que normalmente se consideran «seguras» pueden causar efectos biológicos y clínicos relevantes. Los mecanismos de acción no comprenden sólo la disrupción endocrina. La valoración de la significación clínica y social del espectro de efectos más sutiles y con períodos de latencia mayores de los CTP presenta interesantes retos y oportunidades. España y otros países europeos sufren un déficit de indicadores poblacionales sobre el impacto que los procesos ambientales tienen en la salud humana. Los distintos ámbitos de la Administración deben monitorizar los valores biológicos de los CTPs y valorar sus posibles riesgos para la salud. Junto con más de cien otros países, próximamente España intentará implementar el Tratado sobre los Contaminantes Orgánicos Persistentes (Convenio de Estocolmo. Ello constituye un nuevo motivo para desarrollar programas más eficientes de vigilancia y control de los residuos de los CTP en alimentos, humanos y medio ambiente. Como parte de la aplicación del

  1. Discussion on the source of radon in uranium exploration method using radon-released thermal effect in minerals

    International Nuclear Information System (INIS)

    Su Shoutian.

    1985-01-01

    This paper considers the problem of the source of radon in uranium exploration method using radon-released thermal effect. In minerals by means of scintillation emanometry, we have carried out the measurement on radon content in minerals at various temperature in barren and ore-bearing granites of the granite-type uranium deposit No. 752, and inclusion decrepitation method has also been used to determine the temperature of decrepitation and its relative frequency. It was found from experiments that heated samples may release most of radon prior to inclusion decrepitation, radon released from thermal effect was, on the contrary, very little at temperature intervals of inclusion decrepitation on a large scale basis. When inclusions were ground after radon releasing, it would still release from inclusions after reheating. The radon content calculated from uranium content in inclusions is lower than the sensitivity of the determination method, so it is too difficult to be determined, indicating that the radon content released is not related to inclusions. Samples were determined by uranium chemical analysis and radium radiochemical analysis and it is obvious to note that the radon content released from thermal effect in minerals is positively correlated to the uranium and radium content. Various kinds of experiments suggest that radon is not derived from inclusions but from the whole mineral

  2. Second workshop on radon and radon daughters in urban communities associated with uranium mining and processing

    International Nuclear Information System (INIS)

    1979-01-01

    A second meeting of Atomic Energy Control Board staff, federal and provincial government representatives, and consultants was held to discuss progress in reducing the concentrations of radon and its daughter products in houses in communities like Bancroft, Elliot Lake, Port Hope, and Uranium City. Participants discussed successful and unsuccessful remedial techniques, possible sources of radon, and methods of measuring radon and radon daughters in buildings

  3. Locating and limiting radon in dwellings

    International Nuclear Information System (INIS)

    Hildingson, O.; Gustafsson, J.; Nilsson, I.

    1984-01-01

    More than 3,300 Swedish dwellings have an indoor radon daughter concentration above 400 Bq.m -3 (or 0.108 WL). It is considered to be unsafe to live in any of these dwellings and the radon daughter concentration has to be reduced. Before deciding what measures to take, it is important to determine the radon sources. Possible sources are exhalation from building materials and/or radon transport from the ground into the building through cracks and joints in the slab. Different methods of locating the sources have been developed. To locate cracks and joints in slabs the ventilation rate and the air pressure difference relative to the ground are changed while monitoring radon/radon daughter concentration. The effect of five different measures to reduce the indoor radon daughter concentration have also been evaluated: increased ventilation rate by mechanical ventilation, ventilation of the small spaces between the floor and the slab, sealing the surface of radon exhaling walls, sealing joints and cracks in the slab, and ventilation of the drainage under the slab. (author)

  4. Legal issues in radon affairs

    International Nuclear Information System (INIS)

    Massuelle, M.H.

    1999-01-01

    In France, it was only recently that cases related to high radon concentrations in dwellings received substantial publicity. This irruption of radon as a public health issue came with the general progress of scientific knowledge and the availability of a research capacity in France able to develop expertise. We are interested here in the legal implications of issues that arise from the lag between the activity of experts and the regulatory activity in the domain of radon. We use the term expertise very broadly, to cover the practical application of research findings, the relation of the researchers with the community, and finally the acts by which experts provide their knowledge to the community. We first examine the course by which science developed the radon issue and the way they organized to move from research to expertise; here we try to characterize the various needs for radon expertise. We then discuss the legal difficulties associated with radon expertise

  5. Legal issues in radon affairs

    Energy Technology Data Exchange (ETDEWEB)

    Massuelle, M.H. [Inst. de Protection et de Surete Nucleaire, Fontenay aux Roses (France)

    1999-12-01

    In France, it was only recently that cases related to high radon concentrations in dwellings received substantial publicity. This irruption of radon as a public health issue came with the general progress of scientific knowledge and the availability of a research capacity in France able to develop expertise. We are interested here in the legal implications of issues that arise from the lag between the activity of expertsand the regulatory activity in the domain of radon. We use the term expertise very broadly, to cover the practical application of research findings, the relation of the researchers with the community, and finally the acts by which experts provide their knowledge to the community. We first examine the course by which science developed the radon issue and the way they organized to move from research to expertise; here we try to characterize the various needs for radon expertise. We then discuss the legal difficulties associated with radon expertise.

  6. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample.

    Science.gov (United States)

    Lee, Kil Yong; Burnett, William C

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 °C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods.

  7. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample

    International Nuclear Information System (INIS)

    Kil Yong Lee; Burnett, W.C.

    2013-01-01

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 deg C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods. (author)

  8. Radon anomalies prior to earthquakes (2). Atmospheric radon anomaly observed before the Hyogoken-Nanbu earthquake

    International Nuclear Information System (INIS)

    Ishikawa, Tetsuo; Tokonami, Shinji; Yasuoka, Yumi; Shinogi, Masaki; Nagahama, Hiroyuki; Omori, Yasutaka; Kawada, Yusuke

    2008-01-01

    Before the 1995 Hyogoken-Nanbu earthquake, various geochemical precursors were observed in the aftershock area: chloride ion concentration, groundwater discharge rate, groundwater radon concentration and so on. Kobe Pharmaceutical University (KPU) is located about 25 km northeast from the epicenter and within the aftershock area. Atmospheric radon concentration had been continuously measured from 1984 at KPU, using a flow-type ionization chamber. The radon concentration data were analyzed using the smoothed residual values which represent the daily minimum of radon concentration with the exclusion of normalized seasonal variation. The radon concentration (smoothed residual values) demonstrated an upward trend about two months before the Hyogoken-Nanbu earthquake. The trend can be well fitted to a log-periodic model related to earthquake fault dynamics. As a result of model fitting, a critical point was calculated to be between 13 and 27 January 1995, which was in good agreement with the occurrence date of earthquake (17 January 1995). The mechanism of radon anomaly before earthquakes is not fully understood. However, it might be possible to detect atmospheric radon anomaly as a precursor before a large earthquake, if (1) the measurement is conducted near the earthquake fault, (2) the monitoring station is located on granite (radon-rich) areas, and (3) the measurement is conducted for more than several years before the earthquake to obtain background data. (author)

  9. Efecto de diferentes concentraciones de ácido antranílico en el crecimiento del maíz

    Directory of Open Access Journals (Sweden)

    José Luis Hernández-Mendoza

    2010-01-01

    Full Text Available La rizobacteria Azospirillum brasilense basa su capacidad promotora del crecimiento vegetal en la producción de auxinas y otras hormonas, entre ellas el ácido antranílico (AA. En este trabajo se determinó el efecto del AA (0, 500, 1000, 3000 y 5000 ppm en el crecimiento y la acumulación de biomasa del híbrido de maíz 83G66 en condiciones de invernadero. El AA de 500 a 3000 ppm promovió un mayor crecimiento (área foliar y altura de planta, y el AA de 1000 y 3000 ppm incrementó significativamente la biomasa seca en maíz en comparación con el testigo. El 90% de la asimilación del AA en las plantas ocurrió durante los primeros 10 días después del tratamiento.

  10. Radon legislation and national guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Aakerblom, G

    1999-07-01

    The International Commission on Radiological Protection (ICRP) and The Council of the European Union have recommended the Member States to take action against radon in homes and at workplaces. Within the EU project European Research into Radon in Construction Concerted Action, ERRICCA, the Topic Group on Legal and Building Code Impact was designated to study the current radon legislation and give advice regarding future enactment of laws and recommendations. On behalf of the Group, a questionnaire on radon legislation was sent out to nearly all European states and a selection of non-European states. Questions were asked regarding reference levels for dwellings, workplaces and drinking water, and about regulations or recommendations for building materials and city planning. All 15 EU Member States, 17 non-EU European countries and 10 non-European countries responded to the questionnaire. Their answers are considered current as of the end of 1998. Most European States and many non-European countries have recommended reference levels for dwellings and workplaces, and some have guidelines for measures against radon incorporated in their building codes and guidelines for construction techniques. However, only a few countries have enforced reference levels or regulations for planning and construction. The reference levels for indoor radon concentration in existing and new dwellings or workplaces are within the range 150-1000 Bq/m{sup 3}. Sweden is the only country (Out of 15 EU member states) which has enforced limits for existing dwellings. Sweden and the UK have both enforced levels for new dwellings. 7 non-European countries (Out of 17 responding countries) have enforced levels for existing dwellings and 9 have them for new dwellings. At the end of 1998, only Finland, Sweden, the Czech Republic, Romania, Russia and the Slovak Republic had limits for radon in water, although 8 countries were planning to introduce such limits. The present limits are within the range for

  11. Radon legislation and national guidelines

    International Nuclear Information System (INIS)

    Aakerblom, G.

    1999-07-01

    The International Commission on Radiological Protection (ICRP) and The Council of the European Union have recommended the Member States to take action against radon in homes and at workplaces. Within the EU project European Research into Radon in Construction Concerted Action, ERRICCA, the Topic Group on Legal and Building Code Impact was designated to study the current radon legislation and give advice regarding future enactment of laws and recommendations. On behalf of the Group, a questionnaire on radon legislation was sent out to nearly all European states and a selection of non-European states. Questions were asked regarding reference levels for dwellings, workplaces and drinking water, and about regulations or recommendations for building materials and city planning. All 15 EU Member States, 17 non-EU European countries and 10 non-European countries responded to the questionnaire. Their answers are considered current as of the end of 1998. Most European States and many non-European countries have recommended reference levels for dwellings and workplaces, and some have guidelines for measures against radon incorporated in their building codes and guidelines for construction techniques. However, only a few countries have enforced reference levels or regulations for planning and construction. The reference levels for indoor radon concentration in existing and new dwellings or workplaces are within the range 150-1000 Bq/m 3 . Sweden is the only country (Out of 15 EU member states) which has enforced limits for existing dwellings. Sweden and the UK have both enforced levels for new dwellings. 7 non-European countries (Out of 17 responding countries) have enforced levels for existing dwellings and 9 have them for new dwellings. At the end of 1998, only Finland, Sweden, the Czech Republic, Romania, Russia and the Slovak Republic had limits for radon in water, although 8 countries were planning to introduce such limits. The present limits are within the range for 50

  12. Radon in Dwellings in the Republic of Kalmykia. Results from the National Radon Survey 2006-2007

    International Nuclear Information System (INIS)

    Aakerblom, Gustav; German, Olga; Soederman, Ann-Louise; Stamat, Ivan; Venkov, Vladimir

    2009-02-01

    The National Radon Survey in the Republic of Kalmykia, Russian Federation during 2006-2007 was carried out in a cooperation project between the Swedish Radiation Protection Authority (SSI) and the Russian Institute of Radiation Hygiene (RIRH). In August 2006 SSI, RIRH, federal and local authorities carried out a field study in Kalmykia when radon daughter measurements (equilibrium equivalent radon concentrations in the air) and gamma radiation measurements were made in 103 buildings. Gamma spectrometry measurements were made at several sites. During the visit the cooperating parties devoted some time to the education of local authorities on radon related issues. During three months in the winter season 2006-2007, long term radon trace measurements were made in 525 randomly chosen dwellings in the Republic of Kalmykia. The radon gas activity varied between 3 and 973 Bq/m 3 , with a mean value of 122 Bq/m 3 . In 19 of a total of 835 measurement points, the radon activity exceeded the maximum permitted value in Russia of 200 Bq/m 3 of EERC. The year-round radon trace measurement were made in 20 houses in Elista, the capital of the Republic of Kalmykia, for comparison with the three-month measurements. The year-round measurements showed some higher values for the radon activity, and a correction factor of 0.85 was applied. Using data on the number of people living in detached houses and apartments, and applying the radon activities measured, the number of new lung cancer cases caused by radon was calculated to be 20 to 40 of the 100 new cases reported annually. The methods of construction of the dwellings in Kalmykia is greatly influenced by the history and culture. Most of them were built after World War II and there are only a few that are newly built because of the poor economic situation and the low population growth rate in the Republic. Most people live in detached houses, one-storied with 3-5 rooms, built directly on the ground or on coquina blocks or on a cast

  13. Remedial measures in Swedish and Norwegian houses - application of radon and radon decay product measurements

    International Nuclear Information System (INIS)

    Just, G.; Philipsborn, H. von; Matolin, M.; Molzahn, D.

    1998-01-01

    Houses and apartments in Sweden and Norway with excessive indoor radon concentrations were studied in detail with a variety of methods, standard and novel ones recently developed. For suitable remediation it is necessary to distinguish soil radon and exhalation from blue (porous) concrete. Our CARBOTEST-S is a simple, sensitive, in-situ method to quantify radon exhalation from existing walls, as well as radon permeability of different protective foils and final quality control of foils applied to existing walls. (orig.) [de

  14. Radon levels in Oslo schools

    International Nuclear Information System (INIS)

    Birovlev, A.

    2004-01-01

    Radon measurements using passive CR-39 detectors have been conducted in all schools in Oslo municipality during winter 2003/2004. Results are presented and discussed in the light of qualitative and quantitative factors, some of which are specific for schools as workplaces. Analysis is conducted with respect to factors relating to building construction type, ventilation principle, age of building, building size etc. The influence of ventilation type on radon levels is studied, and problems of investigations based purely on conventional passive radon detectors are noted. Over-estimation of radon concentration by passive detectors and day-night variations of indoor radon levels in buildings with mechanical ventilation systems are discussed. Several guiding principles for planning similar investigations based on above discussions are outlined. (author)

  15. Radon measurements in hispaniola dwellings

    International Nuclear Information System (INIS)

    Gutierrez, J.; Colgan, P.A.; Cancio, D.

    1996-01-01

    The results of a national radon survey and a number of regional surveys of radon in spanish dwelling are reviewed. The best estimate of the geometric mean of indoor radon concentrations is 41.1. Bq/m -3 and single-family dwellings have been shown to be more at risk than apartments. Results need to be interpreted with some caution due to differences in survey methodologies and measurement procedures. The risks from radon exposure are put in perspective by comparison with other voluntary risks. Finally, although a number of 'high risk' areas have already been identified, it is concluded that implementation of a national programme to reduce radon exposure may await a better definition of the problem extent. (authors). 20 refs., 1 tab

  16. Ion climate and radon concentration

    International Nuclear Information System (INIS)

    Busbarna, L.

    1981-01-01

    Characteristic values of radon concentration in natural ion climate and in open air were compared and the effect of artificially produced negative ion excess on the radon concentration of air was studied. The results show that the radon concentration measurable at the rise of negative ion excess is smaller than that in the case of natural equilibrium. This effect can be utilized lowering the background of the scintillation chambers, thus increasing their sensitivity. The negative ions of the artificial ion climate lower radon concentration in closed space. The question arises whether only the ion climate is responsible for the effects on the organism and on the nervous system or the radon concentration of the air also contributes to them. (author)

  17. Contaminación por metales pesados en el sur del Ecuador asociada a la actividad minera

    Directory of Open Access Journals (Sweden)

    Rodrigo Oviedo-Anchundia

    2017-11-01

    Full Text Available En este trabajo se realizó una recopilación de la zona minera más antigua e importante del Ecuador desde su época precolombina hasta la actualidad. Se recolectaron datos que muestran las concentraciones de algunos metales pesados no esenciales (Hg, Pb, As, Mg, Zn, Cd, en los cantones Zaruma y Portovelo de la provincia de El Oro. Los resultados revelaron que los recorridos de los lugares afectados por estos metales van desde el nacimiento de los ríos Calera, Amarillo y Pindo, a lo largo de la cuenca, hasta llegar al río Puyango, donde se obtiene los valores más bajos de estos elementos, a excepción del Manganeso puesto a que su nivel vuelve a elevarse debido a la presencia mineralógica del bosque petrificado de Puyango. Los datos tomados del FONSAD fueron obtenidos del material procesado de los relaves de molienda y colas de cianuración en el año 2004, los mismos demostraron que las concentraciones de plomo y arsénico superaban los valores límites de referencia para estos metales en los suelos. En otros estudios realizados a los pobladores, se tomaron muestras biológicas (sangre, orina y cabello, y con ello se logró determinar que la mayoría de los habitantes de las poblaciones cercanas a la cuenca del río Puyango, se encuentran envenenados con Hg y Pb en pequeñas cantidades dentro de su organismo.

  18. Radon-Instrumentation

    International Nuclear Information System (INIS)

    Moreno y Moreno, A.

    2003-01-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  19. Radon mapping - Santa Barbara and Ventura counties

    International Nuclear Information System (INIS)

    Churchill, R.

    1997-01-01

    Since 1990, the Department of Conservation''s Division of Mines and Geology (DMG) has provided geologic information and conducted several research projects on geology and radon for the California Department of Health Services (DHS) Radon Program. This article provides a brief overview of radon''s occurrence and impact on human health, and summarizes a recent DMG project for DHS that used geologic, geochemical, and indoor radon measurement data to produce detailed radon potential zone maps for Santa Barbara and Ventura counties

  20. Blower door method in radon diagnostics

    International Nuclear Information System (INIS)

    Fronka, A.; Moucka, L.

    2004-01-01

    The idea of the radon transfer factor is commonly presented as the ratio of the building indoor radon concentration to the subsoil radon concentration. Ventilation and the pressure field over the whole building envelope, which varies in a time over a very wide range even in the same building, poses a major problem. Therefore a new approach based on the controlled conditions determining the soil air infiltration was developed. Radon in soil gas infiltrates into the building indoor environment particularly through cracks and other leakages in the structure providing the building contact with its subsoil. The infiltration is driven by the air pressure difference on the two sides of the structure. The pressure difference is caused by the stack effect and its value ranges from 1-2 Pa in family houses to some tens of Pa in higher buildings. Unfortunately, the pressure difference is very unstable under normal conditions, being affected by a host of parameters such as the height of the building, distribution and geometry of leakages, outdoor-indoor temperature difference, etc. Wind direction and velocity of the wind plays a major role. In our research the blower door method was applied in combination with a monitoring of the indoor radon concentration. The indoor-outdoor pressure difference and the pressure difference at the two sides of the screen shutter of the blower door fan are also measured. The blower door ensures a constant, evaluable air exchange rate. The fan power is regulated to provide a stable pressure difference within the range of roughly 5-100 Pa. This approach provides very well defined conditions allowing us to apply a constant ventilation-constant radon supply model. In such circumstances the dynamical changes of radon concentrations are very fast, and therefore a unique continual radon monitor was applied. The radon supply rate is evaluated from the radon steady state of the time course of radon concentration. The dependence of the radon supply rate on

  1. Communicating radon risk effectively: Radon testing in Maryland. Final report

    International Nuclear Information System (INIS)

    Desvousges, W.H.; Smith, V.K.; Rink, H.H.

    1988-10-01

    Two sets of materials and corresponding delivery strategies for communicating radon risk were evaluated, compared with a 'no-special-treatment' strategy in a comparison community. One community received radio public-service announcements and utility bill inserts. The second received these plus posters, local government sponsorship of a radon awareness week, and local slide presentations. The most-intensive efforts (multiple channels, multiple hits) were more effective than the less intensive effort, which had little impact compared with no special treatment. From a marketing perspective, the effort was very successful, increasing the share of homeowners who tested for radon from 5% to 15%. This may not be viewed as sufficiently effective from a public-health perspective, however

  2. Radon as a remedy - radiobiological and medical aspects, risk; Radon als Heilmittel - strahlenbiologische und medizinische Aspekte, Risiko

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, E.R.; Nuernberger, E.; Martignoni, K. [Inst. fuer Strahlenhygiene des Bundesamtes fuer Strahlenschutz, Oberschleissheim/Neuherberg (Germany)

    1995-09-01

    For years there have been controversial discussions about the benefit and risk of radon-balneo-therapy. This is particularly true where the inhalation of radon and its daughter products in curative galleries is concerned. Animal experiments and studies on uranium miners have clearly shown that the exposure with radon and its daughter products is connected with an additional risk for lung cancer. Findings on balneo-therapeutic mechanisms are, at best, incomplete and the topic of controversial discussions in radiobiology. This applies specifically to `hormesis` or `adaptive response`, as indicated in this context. Given the numerous reports of therapeutic results, there appear to be curative effects from radon-balneotherapy for special indications. (orig.) [Deutsch] Nutzen und Risiko der Radon-Balneotherapie werden seit Jahren widerspruechlich diskutiert. Dies gilt insbesondere fuer die Inhalation des Radons und seiner Folgeprodukte in Heilstollen. Tierversuche und Untersuchungen bei Uranbergleuten haben eindeutig gezeigt, dass mit der Exposition durch Radon und seinen Folgeprodukten ein zusaetzliches Lungenkrebsrisiko verbunden ist. Erkenntnisse zum Wirkungsmechanismus der Radon-Balneotherapie liegen allenfalls in Ansaetzen vor und werden in der Strahlenbiologie kontrovers diskutiert. Dies gilt insbesondere fuer die in diesem Zusammenhang angefuehrte `Hormesis` bzw. `Adaptive Response`. Geht man von den zahlreich berichteten therapeutischen Erfahrungen aus, so scheint es Hinweise auf Heileffekte der Radon-Balneotherapie fuer spezielle Indikationen zu geben. (orig.)

  3. Numerical and analytical assessment of radon diffusion in various media and potential of charcoal as radon detector

    Science.gov (United States)

    Rybalkin, Andrey

    Numerical assessments of radon diffusion together with analytical estimates for short-time and long-time exposure were the first objective of this thesis with the goal to demonstrate how radon propagates in various media. Theoretical predictions were compared to numerical simulations, and obtained values of total radon activities inside each material match quite well with the analytical estimates. These estimates, for activated and nonactivated charcoal, were then used to evaluate the possibility of designing a charcoal system to be used as a radon detector. Another objective was to use nonactivated charcoal samples and measure the level of radon accumulation, and use these data to estimate radon diffusion and adsorption coefficients. The analytical approach was developed to estimate these values. Radon adsorption coefficient in nonactivated charcoal was found to be from 0.2 to 0.4 m3/kg. Radon diffusion coefficient for nonactivated charcoal is in the range of 1.2×10-11 to 5.1×10-10 m2/s in comparison to activated charcoal with adsorption coefficient of 4 m3/kg and diffusion coefficient of 1.43×10-9 m2/s. The third objective was to use GEANT4 numerical code to simulate decay of 238U series and 222Rn in an arbitrary soil sample. Based on that model, the goal was to provide a guideline for merging GEANT4 radioactive decay modeling with the diffusion of radon in a soil sample. It is known that radon can be used as an earthquake predictor by measuring its concentration in groundwater, or if possible, along the faults. Numerical simulations of radon migration by diffusion only were made to estimate how fast and how far radon can move along the fault strands. Among the known cases of successful correlations between radon concentration anomalies and earthquake are the 1966 Tashkent and 1976 Songpan-Pingwu earthquakes. Thus, an idea of radon monitoring along the Wasatch Fault, using system of activated/nonactivated charcoals together with solid state radon detectors is

  4. Radon and its daughters in vivo

    International Nuclear Information System (INIS)

    Rundo, J.

    1983-01-01

    Some aspects of the behavior of radon and its short-lived daughters in vivo are described and a relationship between the radon exhalation rate and time after a meal is demonstrated. A major but short-lived postprandial increase in the exhalation rate of radon produced from skeletally-deposited radium was observed and a similar effect in exhalation rate of environmental radon by persons containing no radium was noted. Persons living in houses with elevated concentrations of radon may contain sufficient activity for its detection by external gamma-ray counting. Some of the activity observed is due to inhaled daughter-products in the chest, and some to daughter-products associated with and produced by the decay of radon throughout the body. 3 references, 8 figures. (MF)

  5. ERRICCA radon model intercomparison exercise

    DEFF Research Database (Denmark)

    Andersen, C.E.; Albarracín, D.; Csige, I.

    1999-01-01

    -state diffusive radon profiles in dry and wet soils, (2) steady-state entry of soil gas and radon into a house, (3) time-dependent radon exhalation from abuilding-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive......, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommendedthat additional exercises are carried out....

  6. Radon i danske lejeboliger

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Skytte Clausen, Louise

    I denne undersøgelse kortlægges radonindholdet i indeluften og det undersøges, hvordan indholdet af radon i indeluften er fordelt og spredes i en ejendom, og om det er muligt at pege på en bygningsdel eller en bygningskomponent som en spredningsvej for radon i boliger. Boligerne er lejeboliger og...... ligger i etageejendomme, kæde- og rækkehuse tilhørende bygningstyper opført fra 1850 og frem. De udvalgte ejendomme ligger i områder af landet, hvor der ved tidligere undersøgelser har vist sig at være en stor andel af huse med et højt indhold af radon i indeluften. Koncentrationen af radon er målt over...

  7. Standardised Radon Index (SRI: a normalisation of radon data-sets in terms of standard normal variables

    Directory of Open Access Journals (Sweden)

    R. G. M. Crockett

    2011-07-01

    Full Text Available During the second half of 2002, from late June to mid December, the University of Northampton Radon Research Group operated two continuous hourly-sampling radon detectors 2.25 km apart in the English East Midlands. This period included the Dudley earthquake (ML = 5, 22 September 2002 and also a smaller earthquake in the English Channel (ML = 3, 26 August 2002. Rolling/sliding windowed cross-correlation of the paired radon time-series revealed periods of simultaneous similar radon anomalies which occurred at the time of these earthquakes but at no other times during the overall radon monitoring period. Standardising the radon data in terms of probability of magnitude, analogous to the Standardised Precipitation Indices (SPIs used in drought modelling, which effectively equalises different non-linear responses, reveals that the dissimilar relative magnitudes of the anomalies are in fact closely equiprobabilistic. Such methods could help in identifying anomalous signals in radon – and other – time-series and in evaluating their statistical significance in terms of earthquake precursory behaviour.

  8. Radon problem in uranium industry

    International Nuclear Information System (INIS)

    Khan, A.H.; Raghavayya, M.

    1991-01-01

    Radon emission is invariably associated with the mining and processing of uranium ores. Radon (sup(222)Rn) enters mine atmosphere through diffusion from exposed ore body, fractures and fissures in the rocks and is also brought in by ground water. Being the progenitor of a series of short lived radioisotopes it contributes over 70% of the radiation dose to mine workers and thus accounts for nearly 30% of the total radiation doses received by workers in the whole nuclear industry. This paper summarises the data on radon emanation from the ore body, backfilled sands and mine water. Radon and its progeny concentrations in different haulage levels and stopes of the Jaduguda uranium mine are presented to emphasise the need for a well planned ventilation system to control radiation exposure of miners. Results of radon monitoring from a few exploratory uranium mines are included to indicate the need for a good ventilation system from inception of the mining operations. Relative contribution of mine exhaust and tailings surfaces to the environmental radon are also given. Some instruments developed locally for monitoring of radon and its progeny in mines and in the environment are briefly described to indicate the progress made in this field. (author). 17 refs., 2 figs., 6 tabs

  9. Radon and energy efficient homes

    International Nuclear Information System (INIS)

    Burkart, W.

    1981-09-01

    Radon and its daughters in indoor air are presently responsible for dose equivalents of about 31 mSv/year (3 rem/year) to parts of the respiratory tract. Linear extrapolation from the dose response values of uranium miners heavily exposed to radon and its decay products would suggest that almost all lung cancers in the non-smoking population are caused by environmental 222 Rn. Using epidemiological data on the types of lung cancer found in non-smokers of the general public as compared to the miners, a smaller effect of low level radon exposure is assumed, which would result in a lung cancer mortality rate due to radon of about 10 deaths per year and million or 25% of the non-smoker rate. Higher indoor radon concentrations in energy efficient homes mostly caused by reduced air exchange rates will lead to a several fold increase of the lung cancer incidence from radon. Based on the above assumption, about 100 additional lung cancer deaths/year-million will result both from an increase in radionuclide concentrations in indoor air and a concomitant rise in effectiveness of radiation to cause cancer with higher exposure levels. Possibilities to reduce indoor radon levels in existing buildings and costs involved are discussed. (Auth.)

  10. Aporte del agua de bebida a los requerimientos de calcio de la población costarricense

    OpenAIRE

    Darner Mora Alvarado; Nuria Alfaro Herrera; Carlos Felipe Portuquez

    2000-01-01

    Se presenta la primera investigación a nivel nacional, para determinar el aporte del agua de bebida a los requerimientos de calcio del costarricense, asumiendo una ingesta diaria de 2 litros de agua. Para calcular las concentraciones porcentuales de calcio iónico, se promediaron y agruparon por cantones los contenidos de Carbonato de Calcio (CACO3) de las fuentes de agua utilizadas por acueductos rurales, municipales y los administrados por Acueductos y Alcantarillados; además, como complemen...

  11. Aporte del agua de bebida a los requerimientos de magnesio de la población costarricense

    OpenAIRE

    Darner Mora Alvarado; Nuria Alfaro Herrera; Carlos Felipe Portuguez; José Pablo González

    2000-01-01

    Se presenta un estudio descriptivo en el ámbito nacional, para determinar la contribución del agua de bebida a los requerimientos de magnesio (Mg) en la dieta del costarricense, asumiendo una ingesta diaria de dos litros. Para calcular las concentraciones porcentuales de Mg iónico se promediaron y agruparon por cantones los contenidos de dureza de magnesio, expresada como carbonato de magnesio (MgCO3), de las fuentes de agua utilizadas para los acueductos rurales, municipales y los administra...

  12. Radon monitoring technique with electret collecting

    International Nuclear Information System (INIS)

    Tian Zhiheng; Zuo Fuqi; Xiao Detao; Zhao Xkiuliang

    1991-12-01

    The integrating radon monitoring technique with electret collecting is a method which collects the 218 Po + positive ions by electrostatic field produced by electret. It has greatly improved the sensitivity of radon measurement. The response factor of this method reaches to 4.7 cm -2 Bq -1 m 3 h -1 , 1000 times larger than that of common passive sampling method. The monitoring device and its principle are introduced. The measuring results of radon concentration and radon flux rate and quality assurance system by using this method in the Qinshan Nuclear Power Plant, Human Environmental Monitoring Central Station and some uranium mines are also presented. The analytical results show that the radon concentration in the Qinshan Nuclear Power Plant is affected by wind direction. When wind directs toward sea, the radon concentration is high. If the wind is to the contrary, it is low. The radon concentration ratio of both is about 2

  13. Characterizing the source of radon indoors

    International Nuclear Information System (INIS)

    Nero, A.V.; Nazaroff, W.W.

    1983-09-01

    Average indoor radon concentrations range over more than two orders of magnitude, largely because of variability in the rate at which radon enters from building materials, soil, and water supplies. Determining the indoor source magnitude requires knowledge of the generation of radon in source materials, its movement within materials by diffusion and convection, and the means of its entry into buildings. This paper reviews the state of understanding of indoor radon sources and transport. Our understanding of generation rates in and movement through building materials is relatively complete and indicates that, except for materials with unusually high radionuclide contents, these sources can account for observed indoor radon concentrations only at the low end of the range observed. Our understanding of how radon enters buildings from surrounding soil is poorer, however recent experimental and theoretical studies suggest that soil may be the predominant source in many cases where the indoor radon concentration is high. 73 references, 3 figures, 1 table

  14. Comparative study of radon in Sudan

    International Nuclear Information System (INIS)

    Gharbi, Shaza Ismail Mohammed

    2014-07-01

    This study was conducted primarily to contribute radon data for radon map in Sudan and identify regions with elevated radon levels and improve data collection and analysis for the future radon levels evaluation. This study partially covered three states of Sudan ( Red Sea - Khartoum - South Khordofan). Previous work done has been considered in this study which focused and investigated the levels of radon concentration in ( indoor radon gas and water) by using gamma spectrometry equipped with ( HPGe detector) or (Na1 (T1) detector). The results obtained are within the acceptable levels and dose not poses any risk from radiation protection point of view. Red Sea state ( port-sudan): (124.39±6.21) Bq/m 3 . Khartoum state ( Suba): (151.52) Bq/m 3 . (Omdurman): ( 127±23) Bq/m 3 . Radon in water: (59) Bq/L. South Kordofan State: (102.8) Bq/m 3 . In water (Kadugli): (3 1 39)) Bq/L.(Author)

  15. Estudio del impacto en la calidad del aire de las fuentes puntuales en la ciudad de pinar del Río A study of the impact of stationary sources on the air quality of pinar del Rio city

    Directory of Open Access Journals (Sweden)

    Mariam Fonseca Hernandez

    2013-03-01

    Full Text Available Se realizó un estudio del impacto de las fuentes fijas en la Ciudad de Pinar del Río utilizando el sistema de modelación MM5-CALMET-CALPUFF. Se simuló la dispersión de SO2, NOx, PM25, PM10 y CO emitidos por las 21 fuentes durante 15 días representativos del período lluvioso, además de la depositación húmeda de SO4(2- y NO3-. Se observó que las máximas concentraciones se producen en horarios de la mañana y noche. Se observó que producto de estas emisiones se ven afectados algunas zonas cercanas a la ciudad como Minas de Matahambre, San Juan y Martínez, Santa María, San Luis, El Corojo, Hermanos Saíz, Viñales, Pilotos, Consolación del Sur y las Ovas. Los valores de concentración medios diarios de NOx y SO2 sobrepasaron sus concentraciones máximas admisibles según la NC 39: 1999 y estuvieron por encima de los valores guías de la Organización Mundial de la Salud y los valores estándares EPA.A study of the impact of stationary sources on air quality on the city of Pinar del Rio, Cuba, using the modeling system MM5-CALMET-CALPUFF was made. The dispersion of SO2, NOx, CO, PM10 and PM25 emitted from 21 sources during 15 days is simulated by the model. This period is representative of the rainy season in Cuba (Summer. The of SO4(2- and NO3- wet deposition was also simulated. It was observed that the highest concentrations occur in the morning and evening. These emissions affected some neighboring cities as Santa Maria and Viñales. The daily average concentration values of NOx and SO2 exceeded their maximum permissible concentrations according to the Cuban standards, the guideline values of the World Health Organization and the EPA standards. The southwest area of the city is the most affected one with the highest concentration level.

  16. Utilisation of an Air-conditioning System to Control the Levels of Radon and Radon Progeny in a Workplace Environment

    International Nuclear Information System (INIS)

    Marley, F.

    2000-01-01

    From long-term real-time radon and radon progeny measurements taken in a relatively large retail store, cyclical patterns were evident, which were found to relate to the overriding influence of the timed air-conditioning system. Concentration of radon, radon progeny and the variability of F factor were found to depend significantly on the intermittent operation of this ventilation-air-conditioning system. After pressure equalisation remedial measures proved ineffective, the air-movement system was utilised to reduce the levels of radon and radon progeny to well within established norms applicable during working hours. It is demonstrated that the average levels for radon and radon progeny are reduced in absolute terms. This amounted to less than 12% of the general level, during designated work periods. Where air movement systems are already installed, as well as other circumstances, their regulation provides an economical solution to meeting legal and other standards for radon in the workplace. (author)

  17. Efecto del extracto del fruto de Physalis peruviana "tomatillo" en Mus musculus var. swis con hiperlipidemia inducida.

    Directory of Open Access Journals (Sweden)

    Julio Campos Florián

    2011-01-01

    Full Text Available El objetivo de la presente i nvestigación fue determinar la actividad hipolipidémica del fruto de Physalis peruviana “tomatillo” en un modelo de hiperlipidemia aguda inducida con tritón. Se utilizaron Mus musculus var. swis machos como animales de experimentación. Se trabajó con cuatro grupos de ratones, el grupo blanco recibió agua destilada por vía oral y solución salina fisiológica por vía intraperitoneal, el grupo control recibió agua destilada por vía oral y tritón por vía intraperitoneal, el grupo problema 1 recibió por vía oral 0.05g/100g del extracto de Physalis peruviana y tritón por vía intraperitoneal y el grupo problema 2 recibió por vía oral 0.2g/100g del extracto de Physalis peruviana y tritón por vía intraperitoneal. Luego de 24 horas de administrar los tratamientos se re alizaron las mediciones en suero de las concentraciones de colesterol y triglicéridos. Los niveles promedio de colesterol (mg/dL fueron: 58.87±11.54 (blanco, 121.71±15.00 (control, 58.08±9. 21 (problema 1 y 66.78±16.77 (problema 2. Los niveles promedio de triglicéridos (g/L fueron: 0.48±0.07 (blanco, 1.84±0.18 (control, 0.34±0.10 (problema 1 y 0.94±0.25 (problema 2. Se encontró reducciones significativas (p<0.000, tanto de las concentraciones de colesterol como de triglicéridos en relación a las o btenidas en el grupo tratado sólo con tritón.

  18. Riddle of radon

    International Nuclear Information System (INIS)

    O'Riordan, M.

    1996-01-01

    Why is the most significant source of human exposure to ionising radiation - and one that is so easy to reduce - not accorded the attention it deserves from those engaged in radiological protection nor the action it requires from those affected by it at work or at home? There are, after all, clear indications that high levels of radon exist and firm strands of evidence that radon causes cancer. Some national and international authorities have even developed regulations and recommendations to limit exposures. But radon still lies in the penumbra of protection because proponents of intervention lack conviction and opponents are full of passionate intensity. Little wonder that citizens are confused! (Author)

  19. Tracing and dealing with dwellings with high radon and radon daughter concentrations

    International Nuclear Information System (INIS)

    Ehdwall, Hans

    1980-01-01

    In the late 1970s it was found that a number of buildings in Sweden, primarily those made from alum shale-based concretes, had elevated radon and radon daughter levels. A special commission investigated the problem and established provisional limiting values for radon daughter exposures, gamma radiation from the ground, and the concentrations of radioactive materials in building materials. With regard to gamma radiation from the ground the commission proposed that no building be built in an area where outside gamma radiation exceeds 100 μR/h. For building materials a gamma index (mγ) and a radium index (mRa) are suggested: mγ = Csub(K)/10000 + Csub(Ra)/1000 + Csub(Th)/700; mRa = Csub(Ra)/200 (Csub(K), Csub(Ra) and Csub(Th) are the concentrations of potassium, radium and thorium respectively). The proposed limiting values are such that the gamma index and the radium index be less than 1. It is also suggested that action should be taken to reduce radon levels in buildings with radon daughter concentrations of 0.27 WL within two years and 0.10 WL within 5 years

  20. Environmental radon and cancer risk

    Energy Technology Data Exchange (ETDEWEB)

    Haque, A K.M.M.; Kirk, A E [South Bank Polytechnic, London (United Kingdom)

    1992-01-01

    Data collected from the office of Population Censuses and Surveys (OPCS) statistics and those published by the Leukaemia Research Fund (LRF) have been analysed with a view to examining whether radon is a possible causative agent in the induction of leukaemias. Radon concentration values have been taken from a NRPB survey. Positive correlation has been observed between radon concentration and incidence of acute myeloid leukaemia (AML), chronic myeloid leukaemia (CML), acute lymphoblastic leukaemia (ALL) and chronic lymphoid leukaemia (CLL). Employing the method of BEIR IV, the lifetime probability of leukaemia incidence, R[sub o], of a non-exposed person (zero radon concentration) has been calculated for AML, CML, ALL and CLL, which agree well with those values obtained from extrapolation of linear graphs of leukaemia deaths versus radon concentration. (author).

  1. Radon Infiltration in Rented Accommodation

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2017-01-01

    in homes was measured and the Buildings were registered for a series of variables describing upgrades, facilities, building components, Construction characteristics and used materials. In addition, the radon level was measured in the basement in 9 of the buildings. The mean year value of the indoor radon......Indoor radon levels were measured in 221 homes located in 53 buildings, including 28 multi-occupant houses and 25 single-family terraced houses. The homes consisted of rented accommodation located in buildings recorded as being constructed before 2010 and after the year 1850. The radon level...... radon levels exceeding 100 Bq/m3 in homes in multi-occupant houses was found to be very low, but the risk was highest on the ground floor in a building constructed with slab on ground....

  2. Radon availability in New Mexico

    International Nuclear Information System (INIS)

    McLemore, V.T.

    1995-01-01

    The New Mexico Bureau of Mines and Mineral Resources (NMBMMR) in cooperation with the Radiation Licensing and Registration Section of the New Mexico Environment Department (NMED) and the US Environmental Protection Agency (EPA) have been evaluating geologic and soil conditions that may contribute to elevated levels of indoor radon throughout New Mexico. Various data have been integrated and interpreted in order to determine areas of high radon availability. The purpose of this paper is to summarize some of these data for New Mexico and to discuss geologic controls on the distribution of radon. Areas in New Mexico have been identified from these data as having a high radon availability. It is not the intent of this report to alarm the public, but to provide data on the distribution of radon throughout New Mexico

  3. Behaviors of radon in indoor environment

    International Nuclear Information System (INIS)

    Mochizuki, Sadamu; Shimo, Michikuni.

    1987-01-01

    The source of radon ( 222 Rn) in the atmosphere is radioactive nuclide, uranium ( 238 U), which exists fairly common throughout the earth's crust. Radium ( 226 Ra) descended from uranium produce radon ( 222 Rn) of noble gas by decay. After formation in the ground, radon diffuses into the atmosphere. Without exception radon decay products are heavy metals which soon become attached to natural aerosols. Therefore, radon and its daughters (decay products) appear also in indoor environment, and generally, their concentration levels become higher than that of outdoor air due to build-up effects in the closed indoor environments. With the progress of the study on the influence of radon and its daughers on human health, it has become clear that they act effectively as an exciting cause of lung cancer. So, the study on the risk evaluation of them in room air has become to be very important. Concequently, the behaviors of radon and its daughters in indoor environment, first of all, should be studied in detail for the accurate estimation of the risk caused by them. In this special edition, fundamental characteristics of radon and its daughters, some measuring methods, theoretical considerations and some observational evidences obtained from various circumstances of indoor environment are described inorder to grasp and understand the behaviors of radon and its daughters in the indoor environment. (author)

  4. Ventilation influence upon indoor air radon level

    International Nuclear Information System (INIS)

    Tian Deyuan

    1995-01-01

    Levels of indoor radon in air are studied by a continuous electrostatic radon monitor under normal living conditions to evaluate the influence of air conditioned ventilation on indoor air radon level. Results show that the indoor air radon concentrations are not much more than those without household conditioner living condition, although using household conditioner requires a sealed room which should lead to a higher radon level. Turning on air conditioner helps lower indoor radon level. Therefore, the total indoor air Rn levels are normal > ventilation > exhaust or in-draft > exhaust plus in-draft

  5. Determination of equilibrium factor between radon and its progeny using surface barrier detector for various shapes of passive radon dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Jamil, K. [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group; Fazal-ur-Rehman [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group; Ali, S. [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group; Khan, H.A. [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group

    1997-03-21

    In the field of radon dosimetry, it is customary to measure radon ({sup 222}Rn) concentration while potential health hazard is due to the radon short-lived progeny. When radon is in secular equilibrium, the measured activity of radon equals the activity of radon`s progeny. However, in practical cases an inequilibrium between radon and its progeny exists which is measured in terms of the equilibrium factor. To determine the equilibrium factor between radon and its progeny in a closed environment various shapes of passive dosimeters based upon solid state nuclear track detectors (SSNTDs) are employed. In order to observe the dependence of equilibrium factor upon shapes or effective volumes, experiments have been performed replacing the SSNTDs with a surface barrier detector in Karlsruhe diffusion chamber, pen-type and box-type dosimeters. Using the collected alpha spectra, the equilibrium factor has been determined for a radon-air mixture in a custom designed radon chamber simulating a closed environment of a room. The results show that the radon equilibrium factor is about 0.20 for different shapes of dosimeters studied in this research. It is concluded that the determination of equilibrium factor between radon and its progeny does not depend upon effective volume or shape of the passive dosimeters using alpha spectroscopic data acquired by surface barrier detector. (orig.).

  6. Paloma-radon: Atmospheric radon-222 as a geochemical probe for water in the Martian subsoil.

    Science.gov (United States)

    Sabroux, J.-C.; Michielsen, N.; Voisin, V.; Ferry, C.; Richon, P.; Pineau, J.-F.; Le Roulley, J.-C.; Chassefière, E.

    2003-04-01

    Radon exhalation from a porous soil is known to depend strongly on the soil moisture content: a minute amount of water, or water ice, in the pore space increases dramatically the possibility for radon to migrate far from its parent mineral. We propose to take advantage of this characteristic by using atmospheric radon-222 as a geochemical probe for water in the Martian soil, at least one order of magnitude deeper than the current Mars Odyssey neutron data. Strong thermal inversions during the Martian night will accumulate radon in the lowest atmospheric boundary layer, up to measurable levels despite the comparatively high environmental (cosmic and solar) background radiation and the assumed low uranium content of the upper crust of the planet. Preliminary studies and development of an instrument for the measurement of the Martian atmospheric alpha radioactivity is part of the CNES-supported PALOMA experiment. Two test benches have been implemented, one of them allowing differential measurements of the diffusion of radon in the Martian soil simulant NASA JSC Mars-1, under relevant temperatures and pressures. The other, a 1 m^3 radon-dedicated test bench, aims to characterize the instrument that will measure radon in the Mars environment (7 mb CO_2). Tests on several nuclear radiation detectors show that semiconductor alpha-particle detectors (PIPS) are the best option (already on board the Mars Pathfinder Rover and other platforms). In addition, the detection volume is left open in order to capitalize upon the long (ca. 4 m) alpha track at this low pressure. A stationary diffusion model was developed in order to assess the radon flux at the Mars soil surface. Diffusion of gas in Martian soil is governed by Knudsen diffusion. The radon Knudsen diffusion coefficient was estimated, depending on the soil moisture and relevant structural properties, leading to a radon diffusion length of the order of 20 m. The landed platform PALOMA-Radon instrument will consist of a

  7. Radon: Chemical and physical states of radon progeny. Final technical report

    International Nuclear Information System (INIS)

    Castleman, A.W. Jr.

    1996-01-01

    The evolving chemical and physical form of radon progeny influence their transport to the bioreceptor and the extent to which that receptor can take up these species into various tissues. When first born following radioactive decay processes, the potentially deleterious radon progeny undergo various physical and chemical transformations as they transcend from a highly charged to a neutral state, and interact with various constituents of the environment. These transformations impact on the extent to which the radon progeny become associated with aerosol particles on the one hand, and their ultimate chemical form that is available for uptake in the biosystem, on the other. The program, which originally commenced in 1987, dealt with the basic chemistry and physics of radon progeny and hence impacted on several themes of importance to the DOE/OHER radon program. One of these is dose response, which is governed by the physical forms of the radon progeny, their transport to the bioreceptor and the chemical forms that govern their uptake. The second theme had to do with cellular responses, one of the major issues motivating the work. It is well known that various sizes of ions and molecules are selectively transported across cell membrane to differing degrees. This ultimately has to do with their chemical and physical forms, charge and size. The overall objective of the work was threefold: (1) quantifying the mechanisms and rates of the chemical and physical transformation; (2) ascertaining the ultimate chemical forms, and (3) determining the potential interactions of these chemical species with biological functional groups to ascertain their ultimate transport and incorporation within cells

  8. Radon in coal power plant areas

    International Nuclear Information System (INIS)

    Mauna, Traian; Mauna, Andriesica

    2006-01-01

    Radon, the radioactive colourless and inodorous noble gas, represents more than 55% of the natural average radioactivity. It is permanently released from the soil and majority of building materials, it builds up in the mine galleries, in dwelling houses and in other closed rooms. Radon gained increasingly in importance, particularly after 1990 when was doubtless identified as the second cause of lung cancer if a given concentration threshold is surpassed. This threshold is established differentially by each country as a function of the particular site and generally ranges between 150 Bq.m -3 and 600 Bq.m -3 . The telluric radon consists of two isotopes, 222 Rn, a daughter of radium descending from uranium, which induces 90% of the effects, and 220 Rn from thorium series which have too short a lifetime to count in the risk assessments of radon inhalation. The interest of the authorities and population for diminishing the radon effects was illustrated by specific studies which in USA were managed by the National Counsel of Research, the BEIR VI committee of which has issued a report concerning the lung cancer produced by radon and its descendants. Coal mining, the transport, processing, burning, slag and ash disposal are activities entailing radon release. The miners' dwellings are placed in areas with the high radon potential. The local building materials have a high content of radioactive elements from the uranium or thorium series so that radon can build up in the closed rooms of these buildings. Hence the social responsible authorities in the coal power industry zones should consider this aspect long time ignored in the Balkans macro zone so far. The radon issue must be differentially approached in different areas hence a zonal mapping of the radon emission should be first done. It is worth to underline that the gaseous radioactive emission from operational nuclear power plants amounts up to a few percents of the radon natural emissions what entails a

  9. Radon chamber for soil gas detectors

    International Nuclear Information System (INIS)

    Andersson, P.

    1987-01-01

    Swedish Geological Co (SGAB) has designed and constructed a chamber for the calibration of detectors and instruments intended for the measurement of radon-222 in soil gas. In the chamber radon detectors may be exposed in a model environment which simulates ground conditions with respect to radon concentration, temperature and humidity. Also included in the research project is the development of methods for calibration procedures, together with test measurements. In general, these measurements indicate that the radon detectors tested are sufficiently accurate and reliable for radon measurements in Swedish soils if they are calibrated in an environment which simulates ground conditions. (orig./HP)

  10. Radon adsorption on present activated charcoals

    International Nuclear Information System (INIS)

    Kazankin, Yu.N.; Trofimov, A.M.; Mikhajlova, L.K.

    1978-01-01

    Radon adsorption from helium and air has been studied on modern activated carbons of SKT-1, SKT-2a, SKT-3, SKT-2b, SKT-6, PAU-1 within the temperature range from 100 to 80 deg. It has been shown that PAU-1 carbon has the highest activity with respect to radon in the temperature range studied. With decreasing temperature the adsorption coefficients increase sharply. It has been found that for the case of radon adsorption from helium the logarythm of the Henry coefficient linearly depends on the inverse value of absolute temperature. Adsorption of radon from air is inhibited and the above-cited relationship is deviated from linear. The results of calculating differential heats of radon and air adsorption as well as coefficients of radon and air separation on carbons are presented

  11. NORM and radon in Austria. Status and strategy; Norm und Radon in Oesterreich. Status und Strategie

    Energy Technology Data Exchange (ETDEWEB)

    Maringer, F.J. [Bundesamt fuer Eich- und Vermessungswesen, Wien (Austria)

    2013-07-01

    The author reviews the actual radiation protection practice in Austria for NORM and radon, including possible strategies and developments. Specific topics are radiation protection technologies, metrological resources for NORM in Austria, civil engineering standards (OeNORM) for radon measurement, radon prevention for new buildings and radon cleansing for existing buildings, future assessment and legal regulation of radioactivity in construction materials. The strategic development in Austria considers the current European standard projects (EU standards) and European and international research programs.

  12. Comparative survey of outdoor, residential and workplace radon concentrations

    International Nuclear Information System (INIS)

    Barros, Nirmalla; Field, R. William; Field, Dan W.; Steck, Daniel J.

    2015-01-01

    This study investigated radon concentrations in above-ground (i.e. first floor) workplace in Missouri and compared them with above-ground radon concentrations in nearby homes and outdoor locations. This study also examined the potential utility of using home and outdoor radon concentrations to predict the radon concentration at a nearby workplace (e.g. county agencies and schools). Even though workplace radon concentrations were not statistically different from home radon concentrations, the radon concentration at a particular home, or outdoor location, was a poor predictor of the radon concentration at a nearby workplace. Overall, 9.6 and 9.9 % of homes and workplace, respectively, exhibited radon concentrations of ≥148 Bq m -3 . Because of the percentage of workplace with elevated radon concentrations, the results suggest that additional surveys of workplace radon concentrations are needed, especially in areas of high radon potential, to assess the contribution of workplace radon exposure to an individual's overall radon exposure. (authors)

  13. Reconstruction of national distribution of indoor radon concentration in Russia using results of regional indoor radon measurement programs

    International Nuclear Information System (INIS)

    Yarmoshenko, I.; Malinovsky, G.; Vasilyev, A.; Zhukovsky, M.

    2015-01-01

    The aim of the paper is a reconstruction of the national distribution and estimation of the arithmetic average indoor radon concentration in Russia using the data of official annual 4-DOZ reports. Annual 4-DOZ reports summarize results of radiation measurements in 83 regions of Russian Federation. Information on more than 400 000 indoor radon measurements includes the average indoor radon isotopes equilibrium equivalent concentration (EEC) and number of measurements by regions and by three main types of houses: wooden, one-storey non-wooden, and multi-storey non-wooden houses. To reconstruct the national distribution, all-Russian model sample was generated by integration of sub-samples created using the results of each annual regional program of indoor radon measurements in each type of buildings. According to indoor radon concentration distribution reconstruction, all-Russian average indoor radon concentration is 48 Bq/m"3. Average indoor radon concentration by region ranges from 12 to 207 Bq/m"3. The 95-th percentile of the distribution is reached at indoor radon concentration 160 Bq/m"3. - Highlights: • Reconstruction of indoor radon concentration distribution in Russia was carried out. • Data of official annual 4-DOZ reports were used. • All-Russian average indoor radon concentration is 48 Bq/m"3. • The 95-th percentile is 160 Bq/m"3.

  14. Factors influencing radon attenuation by tailing covers

    International Nuclear Information System (INIS)

    Silker, W.B.; Rogers, V.C.

    1981-07-01

    The US NRC, in its Generic Environmental Impact Statement on uranium milling has specified that the radon flux escaping a uranium mill tailings pile will be reduced to pCi/m 2 s by application of covering layers of soils and clays. These covers present a radon diffusion barrier, which sufficiently increases the time required for radon passage from the tailings to the atmosphere to allow for decay of 222 Rn within the cover. The depth of cover necessary to reduce the escaping radon flux to the prescribed level is to be determined by calculation, and requires precise knowledge of the radon diffusion coefficient in the covering media. A Radon Attenuation Test Facility was developed to determine rates of radon diffusion through candidate cover materials. This paper describes this facility and its application for determining the influence of physical properties of the soil column on the radon diffusion coefficient

  15. Application of underwater radon measurements in geology

    Energy Technology Data Exchange (ETDEWEB)

    Varhegyi, A.; Baranyi, I.; Gerzson, I. (Mecsek Ore Mining Enterprise, Pecs (Hungary)); Somogyi, G.; Hakl, J.; Hunyadi, I. (Magyar Tudomanyos Akademia, Debrecen (Hungary). Atommag Kutato Intezete)

    1988-01-01

    Based on the observed phenomenon of geogas migration in microbubble form from deeper regions, the authors have developed a new model for the vertical transport of radon released from deeper sources. The physical properties of the rock relating to the upflow of microbubbles below the groundwater level are considered and the radon transport parameter of rocks is introduced. The vertical distribution of radon concentration in the case of a multi-layered geological model is given and the penetration depth of underwater radon measurements is examined. Aspects of underwater radon detection by the nuclear track detector technique are analyzed. The radon transport model gives a new theoretical basis for several applications of radon measurements in geology. The advantages of underwater radon detection have already been proved in uranium exploration. Further geological applications are proposed in earthquake prediction, in volcanology, in the survey of active faults and thermal waters. (author).

  16. Radon: A health problem

    International Nuclear Information System (INIS)

    Pucci, J.; Gaston, S.

    1990-01-01

    Nurses can and should function as effective teachers about the potential hazards to health of radon contamination in the home as well as become activists in the development of health care policy on radon

  17. Resultados de las mejoras de la tecnología de los vehículos y de los combustibles en la atmósfera del municipio de Madrid

    OpenAIRE

    Pérez Martínez, Pedro; Monzón de Cáceres, Andrés

    2011-01-01

    El trabajo demuestra que las concentraciones de óxido de azufre y monóxido de carbono han disminuido como consecuencia de los incrementos de la calidad de los combustibles y de las normas de emisión de los vehículos desarrollados durante el periodo de estudio. Sin embargo, las concentraciones de los óxidos de nitrógeno, partículas materiales y ozono se han mantenido constantes pese a la mejora de las emisiones por vehículo, como consecuencia del aumento de la movilidad. Además, las concentra...

  18. Degradación de hidrocarburos aromáticos policíclicos en residuos de barrido de calles del centro de Lima, evaluación del riesgo tóxico y ecotoxicológico

    OpenAIRE

    Visitación Figueroa, Lizardo

    2016-01-01

    Universidad Nacional Agraria La Molina. Escuela de Posgrado. Doctorado en Ingeniería Ambiental En el presente estudio se determinó la concentración de los 16 Hidrocarburos Aromáticos Policíclicos (HAPs) potencialmente cancerígenos, en residuos de barrido de calles y material particulado PM-10 provenientes del centro de Lima-Perú, durante los meses de agosto y diciembre del 2013. Las muestras de residuos de barrido de calles presentaron concentraciones que varían entre 14.15 a 73.93 μg/g, l...

  19. Comparative study on radon effects and thermal effects on humans in radon hot spring therapy

    International Nuclear Information System (INIS)

    Yamaoka, K.; Mitsunobu, F.; Hanamoto, K.; Tanizaki, Y.; Sugita, K.; Kohima, S.

    2003-01-01

    Full text: The radon therapy is used radon ( 222 Rn) gas, which mainly emits alpha-rays, and induces a small amount of active oxygen in the body. Because most of the diseases to which the radon therapy as well as the thermal therapy is applied are related to activated oxygen, in this study the effects of the radioactivity of radon and thermal effects were compared under the room or the hot spring condition with the similar chemical component, using as the parameters which are closely involved in the clinical for radon therapy. In the results, the radon and thermal therapy enhanced the antioxidation function, such as the activities of superoxide dismutase (SOD) and catalase, which inhibit lipid peroxidation and total cholesterol produce in the body. Moreover the therapy enhanced concanavalin A (ConA)-induced mitogen response, and increased the level of CD4, which is the marker of helper T cell, and decreased the level of CD8, which is the common marker of killer T cell and supresser T cell, in the white cell differentiation antigen (CD4/CD8) assay. Furthermore, the therapy increased the levels of alpha atrial natriuretic polypeptide (alpha ANP), beta endorphin, adrenocorticotropic hormone (ACTH), insulin and glucose-phosphate dehydrogenase (G-6-PDH), and decreased the vasopression level. The results were on the whole larger in the radon group than in the thermal group. The findings suggest that the radon therapy more contributes to the prevention of life style-related diseases related to peroxidation reactions and immune depression than thermal therapy. Moreover these indicate what may be a part of the mechanism for the alleviation of hypertension, osteoarthritis (pain) and diabetes mellitus brought about more radon therapy than thermal therapy

  20. The matter of radon

    International Nuclear Information System (INIS)

    O'Riordan, M.C.; O'Riordan, C.N.

    1992-01-01

    By comparison with the radiation doses from radon, the doses to individual members of the public and to the general community from nuclear activities are quite trivial. Doses from radon in some British homes exceed the statutory dose limit for nuclear workers;the collective dose from radon is two thousand times the value for nuclear discharges. And yet, too little attention - legal or otherwise - is paid to this radioactive pollutant. An attempt is made in this paper to compensate for the neglect. The origins, properties and harmful effects of radon are described. Measurements in homes and places of work are summarised. Voluntary and regulatory controls on exposure are elucidated. Questions of public administration, confidentiality of information and sale of property are discussed. Prospects for progress are assessed. (author)

  1. Passive radon daughter dosimeters

    International Nuclear Information System (INIS)

    McElroy, R.G.C.; Johnson, J.R.

    1986-03-01

    On the basis of an extensive review of the recent literature concerning passive radon daughter dosimeters, we have reached the following conclusions: 1) Passive dosimeters for measuring radon are available and reliable. 2) There does not presently exist an acceptable passive dosimeter for radon daughters. There is little if any hope for the development of such a device in the foreseeable future. 3) We are pessimistic about the potential of 'semi-passive dosimeters' but are less firm about stating categorically that these devices cannot be developed into a useful radon daughter dosimeter. This report documents and justifies these conclusions. It does not address the question of the worker's acceptance of these devices because at the present time, no device is sufficiently advanced for this question to be meaningful. 118 refs

  2. Radon levels in Croatian spas

    International Nuclear Information System (INIS)

    Radolic, V.; Vukovic, B.; Stanic, D.; Planinic, J.

    2005-01-01

    Average radon concentrations in the air and geothermal water of spa pools in Croatia were 40.3 Bq/m 3 and 4.5 kBq/m 3 , respectively. Substantial difference between radon concentrations in pool and spring water is explained by the mixing normal and geothermal water in the pool and with radon decay. The estimated annual effective dose received by the personnel in the spa of Stubicke toplice, Croatia was 0.7 mSv. At the same location, the calculated transfer factor of radon for the air and thermal water in the pool was 4.9x10 -3 .(author)

  3. Application of CR-39 to radon measurement

    International Nuclear Information System (INIS)

    Miyake, Hiroshi

    1988-01-01

    CR-39, an ally diglycol carbonate, has recently come into wider use as material for solid-state track detector. Etching with NaOH or KOH solution allow CR-39 to develop extremely clear etch pits attributed to alpha rays. The most widely used method for measuring radon concentration employs a plastic cup with a solid-state track detector mounted at its bottom to detect alpha rays resulting from radon or its daughters that disintegrate within or on the wall of the cup. Simple in mechanism and low in cost, this method is suitable for such a case where the radon concentration distribution over a wide area has to be measured by using a large number of devices. The concentration of radon alone can be measured with the aid of a filter attached to the mouth of the cup to remove the daughters of radon and thoron. The simplest and most effective way of improving the sensitivity of a solid-state track detector for radon concentration measurement is to electrostatically collect daughters resulting from decay of radon onto the surface of the detector. Another method widely used to determine the radon concentration is to measure the concentration of the radon daughters instead of direct measurement of the concentration of radon itself. (Nogami, K.)

  4. Training and Accreditation for Radon Professionals in Sweden

    International Nuclear Information System (INIS)

    Soderman, A. L.

    2003-01-01

    Radon training courses and seminars of different kinds have been arranged in Sweden since the early 1980s. A commercial educational company initiated the first regular training courses in 1987. Up to 1990 about 400 persons had attended courses in radon measurement and radon mitigation methods. In 1991 the first in a series of courses focussed on radon from the ground and production of radon risk maps organised. From 1991 it has been possible to obtain accreditation for measurements of indoor radon in Sweden and from 1997 also for measurements of radon in water. Even if accreditation s is voluntary, in Sweden accredited laboratories perform most measurements, both for indoor air and water. A condition for accreditation in to have passed the examination following the training courses at SSI, SO far, three major companies have obtained accreditation for measurement of indoor radon and four have been accredited for measurements of radon in water. Education on radon is also given at universities and institutes of technology. A two-day course is included in the education for environmental health officers. A number of training courses aimed at real state agents have been organised by SSI through the years. During the autumn of 2001 altogether 400 authorised real estate agents attended a series of regional half-day courses. In 1995 SSI arranged an international training course, Radon Indoor Risk and Remedial Actions, in Stockholm for the European commission. About 40 scientists from all over Europe attended the course, which much appreciated by the participants. Today SSI's Radon Training Programme comprises five different courses, a Basic radon Course and four continuation courses: Radon measurements, Radon remedial measures, Radon in water and Radon investigation and risk map production. The courses are arranged twice a year, in spring and autumn, except the Radon risk map production course, which is arranged about every second year. Altogether, between 1991 and 2003

  5. El Derecho de Competencia Económica en la Constitución del Ecuador

    Directory of Open Access Journals (Sweden)

    Marcelo Marín Sevilla

    2011-12-01

    Full Text Available Este trabajo permite establecer las bases de la Constitución Económica y del Derecho de Competencia Constitucionalizado.  También analiza si las normas de Derecho de la Competencia Económica y su doctrina están acorde y son adecuadas frente a la Constitución del Ecuador. El Derecho de la Competencia Económica tiene normas para investigar y sancionar las Prácticas colusorias; los Abusos de posición de dominio; las normas  para el control de concentraciones económicas; las conductas de Abuso de dependencia económica, y las conductas  de competencia desleal.  Siempre la Autoridad de Competencia analizará estas conductas en función del bienestar del mercado y del consumidor.

  6. Evaluación de la mutagenicidad causada por metales pesados presentes en agua del río Cauca en la ciudad de Cali, Colombia

    Directory of Open Access Journals (Sweden)

    Aura H. Vivas

    2014-05-01

    Full Text Available Se evaluó la mutagenicidad del agua del río Cauca debida a la presencia de metales pesados en la zona urbana de la Ciudad de Santiago de Cali, a partir de muestras tomadas en la temporada seca y lluviosa en el año 2013. Los metales se extrajeron pasando el agua por la resina Amberlite XAD-16. Las concentraciones de los metales pesados se midieron por absorción atómica y la mutagenicidad se evaluó por medio del test de Ames, con las cepas TA98 y TA100 de Salmonella typhimurium con y sin activador enzimático S9. Los resultados mostraron índices de mutagenicidad (IM positivos (IM > 2,0 para muestras colectadas en temporada lluviosa en tres de los cinco puntos evaluados: puente El Hormiguero (IM = 3,6, desembocadura del Canal Colector Sur (IM = 2,9 y desembocadura del río Cali (IM = 2,7, todos con la cepa TA98 sin S9. Estos sitios presentaron a su vez las mayores concentraciones totales de metales pesados en sus extractos. El análisis de la variación espacio-temporal del índice mutagénico se realizó haciendo un análisis de varianza multifactorial del IM. Los resultados encontrados indican que la época de muestreo contribuye significativamente a la variabilidad del IM, mientras que los puntos de muestreo no.

  7. A statistical evaluation of the geogenic controls on indoor radon concentrations and radon risk

    Energy Technology Data Exchange (ETDEWEB)

    Appleton, J.D., E-mail: jda@bgs.ac.u [British Geological Survey, Kingsley Dunham Centre, Nicker Hill, Keyworth, Nottingham, NG12 5GG (United Kingdom); Miles, J.C.H. [Health Protection Agency (HPA), Radiation Protection Division, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom)

    2010-10-15

    ANOVA is used to show that approximately 25% of the total variation of indoor radon concentrations in England and Wales can be explained by the mapped bedrock and superficial geology. The proportion of the total variation explained by geology is higher (up to 37%) in areas where there is strong contrast between the radon potential of sedimentary geological units and lower (14%) where the influence of confounding geological controls, such as uranium mineralisation, cut across mapped geological boundaries. When indoor radon measurements are grouped by geology and 1-km squares of the national grid, the cumulative percentage of the variation between and within mapped geological units is shown to be 34-40%. The proportion of the variation that can be attributed to mapped geological units increases with the level of detail of the digital geological data. This study confirms the importance of radon maps that show the variation of indoor radon concentrations both between and within mapped geological boundaries.

  8. Comparison of calculated and measured soil-gas radon concentration and radon exhalation rate

    International Nuclear Information System (INIS)

    Neznal, Martin; Neznal, Matej; Jiranek, Martin

    2000-01-01

    The computer model RADON2D for WINDOWS, which makes it possible to estimate the radon exhalation rate from the ground surface and the distribution of soil-gas radon concentration, was tested using a large set of experimental data coming from four reference areas located in regions with different geological structure. A good agreement between calculated and experimental data was observed. In the majority of cases, a correct description of the real situation was obtained using non-modified experimental input data. (author)

  9. Field demonstrations of radon adsorption units

    International Nuclear Information System (INIS)

    Abrams, R.F.

    1989-01-01

    Four radon gas removal units have been installed in homes in the Northeast U.S. These units utilize dynamic adsorption of the radon gas onto activated charcoal to remove the radon from room air. Two beds of charcoal are used so that one bed removes radon while the second bed is regenerated using outdoor air in a unique process. The beds reverse at the end of a predetermined cycle time, providing continuous removal of radon from the room air. The process and units have undergone extensive development work in the laboratory as well as in homes and a summary of this work is discussed. This work showed that the system performs very effectively over a range of operating conditions similar to those found in a home. The field test data that is presented shows that scale up from the laboratory work was without problem and the units are functioning as expected. This unit provides homeowners and mitigation contractors with another option to solve the radon gas problem in homes, particularly in homes that it is difficult to prevent radon from entering

  10. Radon

    International Nuclear Information System (INIS)

    Holmen, R.W.

    1987-01-01

    The discovery that radon enters into residential and commercial structures and produces adverse health consequences to occupants thereof has raised issues for the real estate profession in connection with transactions involving affected structures. The legal responsibilities of real estate professionals in relation to such structures have not yet been clearly defined. Moreover, consistent and reliable testing methods and results, clear identification of circumstances where testing is necessary, and consensus as to health risks suggested by various radon levels have yet to be achieved. When these legal and technical questions are clarified, real estate buyer and sellers as well as agents and brokers will be greatly benefited

  11. Indoor radon concentrations in Vushtrri, Kosovo

    International Nuclear Information System (INIS)

    Xhafa, B.; Jonuzaj, A.; ); Bekteshi, S.; Ahmetaj, S.; Kabashi, S.; )

    2009-01-01

    Indoor air radon concentration was measured by exposing trac ketch detectors in the two elementary schools, one high school, a kindergarten and the hospital in the city of Vushtrri. Measurements were performed with the radon monitor PRM-145, which uses alpha scintillation cells and serves to determine the current concentration of radon. The results we obtained are in the range between the average values of radon for the interior spaces, and values that pose a potential risk for lung cancer. Measuring the concentration of radon was done in total of 34 rooms and came up with values which are between 28Bqm -3 and 398Bqm -3 . In order to reduce the concentration of radon, we have built a ventilation pump, then we performed repeated measurements and finally came with results between 130-145Bqm -3 .

  12. Radon reduction in crawl-space houses

    International Nuclear Information System (INIS)

    Osborne, M.C.; Moore, D.G.; Southerlan, R.E.; Brennan, T.; Pyle, B.E.

    1989-01-01

    This paper gives results of an EPA study of radon-mitigation alternatives for crawl space houses in several houses in Nashville, TN. Application of one of these alternative mitigation options, suction under a polyethylene membrane, has been successful in significantly reducing radon levels in both the crawl space and the house. The large radon concentrations measured under unvented plastic ground covers and the moisture barriers found in many crawl spaces can act as radon-rich reservoirs capable of contaminating a crawl space and house during periods of depressurization. With the exhaust components of the mitigation system in place, radon levels below the plastic decreased by more than 95% under both passive and active suction conditions. Based on the study, the design of a cost-effective subplastic suction passive radon mitigation system for crawl spaces seems promising

  13. A complete low cost radon detection system

    International Nuclear Information System (INIS)

    Bayrak, A.; Barlas, E.; Emirhan, E.; Kutlu, Ç.; Ozben, C.S.

    2013-01-01

    Monitoring the 222 Rn activity through the 1200 km long Northern Anatolian fault line, for the purpose of earthquake precursory, requires large number of cost effective radon detectors. We have designed, produced and successfully tested a low cost radon detection system (a radon monitor). In the detector circuit of this monitor, First Sensor PS100-7-CER-2 windowless PIN photodiode and a custom made transempedence/shaping amplifier were used. In order to collect the naturally ionized radon progeny to the surface of the PIN photodiode, a potential of 3500 V was applied between the conductive hemi-spherical shell and the PIN photodiode. In addition to the count rate of the radon progeny, absolute pressure, humidity and temperature were logged during the measurements. A GSM modem was integrated to the system for transferring the measurements from the remote locations to the data process center. - Author-Highlights: • Low cost radon detection. • Integrated GSM modem for early warning of radon anomalies. • Radon detection in environment

  14. Characterization of radon levels in indoor air

    International Nuclear Information System (INIS)

    George, A.C.

    1982-01-01

    The purpose is to describe the different types of monitoring and sampling techniques that can determine the radiation burden of the general public from radon and its decay products. This is accomplished by measuring the range and distribution of radon and radon decay products through broad surveys using simple and convenient integrating monitoring instruments. For in-depth studies of the behavior of radon decay products and calculation of the radiation dose to the lung, fewer and more intensive and complex measurements of the particle size distribution and respiratory deposition of the radon decay products are required. For diagnostic purposes, the paper describes measurement techniques of the sources and exhalation rate of radon and the air exchange inside buildings. Measurement results form several studies conducted in ordinary buildings in different geographical areas of the United States, using the described monitoring techniques, indicate that the occupants of these buildings are exposed to radon and radon decay product concentrations, varying by as much as a factor of 20

  15. An overview of Ireland's National Radon Policy

    International Nuclear Information System (INIS)

    Long, S.; Fenton, D.

    2011-01-01

    In Ireland radon is a significant public health issue and is linked to 150-200 lung cancer deaths each year. Irish National Radon Policy aims to reduce individual risk by identifying and remediating buildings with high radon concentrations and also to reduce collective dose through radon prevention as required by revised building regulations. Achievements to date are significant and include the completion of the National Radon Survey, the testing of every school in Ireland, the on-going testing of social housing, collaboration between the public health and radiation protection authorities and the inclusion of radon in inspections of workplaces. However, this work now needs to be drawn together centrally to comprehensively address the radon problem. The RPII and the relevant central governing department, the Dept. of Environment, Heritage and Local Government are currently working to constitute a group of key experts from relevant public authorities to drive the development of a National Radon Control Strategy. (authors)

  16. Measuring your radon risk

    International Nuclear Information System (INIS)

    Mackmurdo, R.

    1994-01-01

    In its annual report for 1992/93, the NRPB has warned that tens of thousands of UK employees may be exposed to high levels of radon at work. In addition to those who work underground, employees at risk of radon-induced lung cancer are typically those who spend long periods indoors. This article reviews the implications for all employers especially those in low or unknown levels of radon who resist taking measurements in the belief that by not measuring, they are not liable. (UK)

  17. Determination of equilibrium factor between radon and its progeny using surface barrier detector for various shapes of passive radon dosimeters

    International Nuclear Information System (INIS)

    Jamil, K.; Fazal-ur-Rehman; Ali, S.; Khan, H.A.

    1997-01-01

    In the field of radon dosimetry, it is customary to measure radon ( 222 Rn) concentration while potential health hazard is due to the radon short-lived progeny. When radon is in secular equilibrium, the measured activity of radon equals the activity of radon's progeny. However, in practical cases an inequilibrium between radon and its progeny exists which is measured in terms of the equilibrium factor. To determine the equilibrium factor between radon and its progeny in a closed environment various shapes of passive dosimeters based upon solid state nuclear track detectors (SSNTDs) are employed. In order to observe the dependence of equilibrium factor upon shapes or effective volumes, experiments have been performed replacing the SSNTDs with a surface barrier detector in Karlsruhe diffusion chamber, pen-type and box-type dosimeters. Using the collected alpha spectra, the equilibrium factor has been determined for a radon-air mixture in a custom designed radon chamber simulating a closed environment of a room. The results show that the radon equilibrium factor is about 0.20 for different shapes of dosimeters studied in this research. It is concluded that the determination of equilibrium factor between radon and its progeny does not depend upon effective volume or shape of the passive dosimeters using alpha spectroscopic data acquired by surface barrier detector. (orig.)

  18. Radon in the indoor environment

    International Nuclear Information System (INIS)

    Vanmarcke, H.

    1998-01-01

    A precise retrospective assessment of long-term radon exposures in dwellings is essential for estimating lung-cancer risks. The objectives of this research are (1) to investigate the deposition of radon progeny in the human respiratory tract by means of direct measurements as a function of aerosol conditions, (2) to assess the radon concentrations in buildings retrospectively with volume traps

  19. Radon in the indoor environment

    International Nuclear Information System (INIS)

    Vanmarcke, H.

    1998-01-01

    The objectives of R and D on radon in the indoor environment at SCK-CEN is to (1) to investigate the deposition of radon progeny in the human respiratory tract by means of direct measurements as a function of aerosol conditions; to assess the radon concentrations in buildings retrospectively with volume traps. Progress and main achievements in 1997 are reported on

  20. Emission of radon from soil

    International Nuclear Information System (INIS)

    Ahlberg, P.; Lindmark, A.; Rosen, B.

    1980-03-01

    The report deals with the measurement of radon daughters in the soil Radon migrates readily through the limestone which is superpositioned the alum shale. The level of gamma radiation is normal. Measurements have been made by the track etch technique and with Kodak film. The contents of radon daughters are shown to be due to the measuring depth. (G.B.)

  1. Measurements of radon and chemical elements: Popocatepetl volcano; Mediciones de radon y elementos quimicos: Volcan Popocatepetl

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Segovia, N.; Lopez, B.; Reyes, A.V. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Armienta, M.A.; Valdes, C.; Mena, M. [IGFUNAM, Ciudad Universitaria, 04510 Mexico D.F. (Mexico); Seidel, J.L.; Monnin, M. [UMR 5569 CNRS Hydrosciences, Montpellier (France)

    2002-07-01

    The Popocatepetl volcano is a higher risk volcano located at 60 Km from Mexico City. Radon measurements on soil in two fixed seasons located in the north slope of volcano were carried out. Moreover the radon content, major chemical elements and tracks in water samples of three springs was studied. The radon of soil was determined with solid detectors of nuclear tracks (DSTN). The radon in subterranean water was evaluated through the liquid scintillation method and it was corroborated with an Alpha Guard equipment. The major chemical elements were determined with conventional chemical methods and the track elements were measured using an Icp-Ms equipment. The radon on soil levels were lower, indicating a moderate diffusion of the gas across the slope of the volcano. The radon in subterranean water shown few changes in relation with the active scene of the volcano. The major chemical elements and tracks showed a stable behavior during the sampling period. (Author)

  2. Radon and radon daughters' concentration in spring and wells waters from Presidente Prudente: preliminary results

    International Nuclear Information System (INIS)

    Osorio, Ana Maria Araya; Saenz, Carlos Alberto Tello; Pereira, Luiz Augusto Stuani

    2009-01-01

    This work presents the preliminary results about the concentration of radon and radon daughters in wells and springs water from Presidente Prudente. Six water samples were studied: three from well-water, two from springs water and one from potable water. For the determination of α-activity the samples were placed inside plastic containers where the CR-39 tracks detectors were outside the water. The track density of α-particles were measured by using optical microscopy. The results show that one sample from well-water presented higher concentration of radon and radon daughters than the other samples. (author)

  3. Radon in dwellings the national radon survey Cavan, Dublin, Louth, Monaghan and Wicklow

    International Nuclear Information System (INIS)

    Duffy, J.T.; Mackin, G.M.; Fennell, S.G.; Madden, J.S.; McGarry, A.T.; Colgan, P.A.

    1996-10-01

    This report presents the first results of the National Radon Survey carried out by the Radiological Protection Institute of Ireland. The average radon concentrations for the houses measured in counties Cavan, Dublin, Louth, Monaghan and Wicklow ranged from 69 to 138 Bq/m 3 with individual values as high as 1000 Bq/m 3 . The measurement data were grouped on the basis of the 10 km grid squares of the Irish National Grid System and used to predict the percentage of dwellings in each grid square which exceeds the Reference Level of 200 Bq/m 3 . Grid squares where this percentage is predicted to be 10% or higher are designated High Radon Areas. The health effects of exposure to high radon levels are discussed and recommendations are made regarding both new and existing dwellings

  4. Training and accreditation for radon professionals in Sweden

    International Nuclear Information System (INIS)

    Mjoenes, L.; Soederman, A.-L.

    2004-01-01

    Radon training courses and seminars on radon have been arranged in Sweden since the early 1980s. A commercial educational company initiated the first regular training courses in 1987. Up to 1990 about 400 persons had attended courses in radon measurement and radon mitigation methods. In 1991 the training programme was taken over by the Swedish Radiation Protection Authority, SSI. Today SSI's Radon Training Programme comprises three different two-day courses, a Basic Radon Course and two continuation courses: Radon Measurements and Radon in Water. Until 2003 SSI also arranged courses about Radon Remedial Measures and Radon Investigation and Risk Map Production. The courses are arranged twice a year. Altogether, about 750 municipal environmental health officers and technicians from private companies have been educated in the SSI training programme between 1991 and 2003. The continuation courses are completed with an examination, consisting of a theoretical test. The names of the persons who pass are being published in a list that is found on the SSI web site. Since no certification system is currently in place for radon professionals in Sweden, this list helps people who need to get in contact with radon counsellors to find one in their area and is used by authorities as well as private house-owners. Since 1991 it has been possible to obtain accreditation for measurements of indoor radon in Sweden and since 1997, also for measurements of radon in water. Although accreditation is voluntary in Sweden, accredited laboratories perform most measurements, both for indoor air and water. Passing the examination in the SSI training courses is a condition for accreditation. The Swedish Board for Accreditation and Conformity Assessment, SWEDAC, is in charge of the accreditation. So far, three major companies have obtained accreditation for measurement of indoor radon and four have been accredited for measurements of radon in water

  5. Membrane barriers for radon gas flow restrictions

    International Nuclear Information System (INIS)

    Archibald, J.F.

    1984-08-01

    Research was performed to assess the feasibility of barrier membrane substances, for use within mining or associated high risk environments, in restricting the diffusion transport of radon gas quantities. Specific tests were conducted to determine permeability parameters of a variety of membrane materials with reference to radon flow capabilities. Tests were conducted both within laboratory and in-situ emanation environments where concentrations and diffusion flows of radon gas were known to exist. Equilibrium radon gas concentrations were monitored in initially radon-free chambers adjacent to gas sources, but separated by specified membrane substances. Membrane barrier effectiveness was demonstrated to result in reduced emanation concentrations of radon gas within the sampling chamber atmosphere. Minimum gas concentrations were evidenced where the barrier membrane material was shown to exhibit lowest radon permeability characteristics

  6. A survey on radon reduction efficiency of zeolite and bentonite in a chamber with artificially elevated radon concentration

    International Nuclear Information System (INIS)

    Mortazavi, S.M.J.

    2007-01-01

    Complete text of publication follows. Objective: Zeolite which is made of a special crystalline structure is a naturally occurring mineral group and can be used in radioactive waste management for site remediation /decontamination. There are a wide variety of naturally occurring and synthetic zeolites, each with a unique structure. The cations in zeolite are highly mobile and can be exchanged for other cationic species. On the other hand, bentonite forms from weathering of volcanic ash. This material may be used as an engineering barrier to enclose nuclear waste. In this study, radon reducing properties of zeolite and bentonite have been investigated. Methods: Using radioactive lantern mantle, a radon prone area with radon levels reaching the EPA's action level (200 Bq/m 3 ) was designed. Two sets of identical chambers (cylindrical chambers, diameter 10 cm, height 16 cm) were used in this study. No zeolite/bentonite was used in the 1 st set of the chambers. A thin layer of either zeolite or bentonite powder was applied to the base of the first set of chambers. An unburned radioactive lantern mantle (activity 800 Bq) was placed in all chambers (both sets) to artificially increase the radon level inside the chamber and simulate the condition of a radon prone area. Radon level monitoring was performed by using a PRASSI portable radon gas survey meter. Results: After placing the cap on its place, the radon levels inside the 1 st set of the chambers were 871.9, 770.3, 769.2 and 635.7 Bq/m 3 after 15, 30, 45 and 60 minutes respectively. Zeolite significantly decreased the radon concentration inside the chambers and radon levels were 367.9, 435.4, 399.0 and 435.4 Bq/m 3 after 15, 30, 45 and 60 minutes. The observed reduction in the radon level was statistically significant. As the radon concentrations in identical chambers with Bentonite were 550.7, 526.5, 536.2 and 479.8 Bq/m 3 after 15, 30, 45 and 60 minutes respectively, it is evident that zeolite is more efficient in

  7. Radon in the Environment: Friend or Foe?

    International Nuclear Information System (INIS)

    Hussein, A.S.

    2009-01-01

    Radon 222 is a naturally occurring radioactive gas that is part of the Uranium decay series. Its Presence in the environment is associated mainly with trace amounts of uranium and its immediate parent, radium 226 , in rocks, soil and groundwater. About one-half of the effective doses from natural sources is estimated to be delivered by inhalation of the short lived radon progeny. Owing to this fact, radon is the most popular subject of studies on environmental radioactivity. The presence of high level of radon in indoor environment constitutes a major health hazard for man. The radon progeny is well established as causative agents of lung cancer and other types of caners. Radon unique properties as a naturally radioactive gas have led to its use as a geophysical tracer for locating buried faults and geological structures, in exploring for uranium, and for predicting earthquakes. Radon has been used as a tracer in the study of atmospheric transport process. There have been several other applications of radon in meteorology, water research and medicine. This paper summarizes the health effects and the potential benefits of radon and its progeny.

  8. Mapping of groundwater radon potential

    International Nuclear Information System (INIS)

    Aekerblom, G.; Lindgren, J.

    1997-01-01

    The domestic use of water with elevated radon concentration may represent a public health hazard, partly due to the release of radon to the indoor air. While only a limited number of countries have implemented regulations with respect to radon in water, many more are considering doing so. The compulsory limits proposed by Swedish authorities are 100 Bq/1 for public water, while water from private wells is not to exceed 1000 Bq/1. Furthermore, it is recommended that water with a radon content above 500 Bq/1 should not be given to children under five years of age. In Sweden, the estimated number of wells with radon levels above 1000 Bq/1 exceeds 10,000, with a considerable amount in excess of 10,000 Bq/1. The highest radon concentration in a well supplying drinking water encountered so far is 57,000 Bq/1. Radon levels exceeding 500 Bq/1 are almost exclusively found in wells drilled into bedrock and in springs with intramontaneous water. Elevated ground water radon levels require that the water has passed through bedrock with elevated concentration of uranium, or through fractures with coatings of minerals containing enhanced concentrations of radium-226. Intramontaneous water from areas with uranium-bearing rock types (e.g. uranium-rich granites, pegmatites and vulcanites) often manifests elevated radon levels. Routines for the establishment of risk maps focusing on water are currently under development. The backbone of the process is the access to high spatial resolution radiometric information together with bedrock and soil information on a detailed scale (1:50,000). This information is available from the Geological Survey of Sweden, which is routinely carrying out airborne measurements at an altitude of 30 m and a line spacing of 200 m. While some 60% of Sweden is covered up to now, 75 % is expected to be covered within the next ten years. Other available databases utilized in the risk mapping process include radon measurements in wells, geochemical data from

  9. Radon gas as a tracer for volcanic processes

    International Nuclear Information System (INIS)

    Thomas, D.M.

    1990-01-01

    Radon emissions from volcanic systems have been under investigation for several decades. Soil gas and groundwater radon activities have been used to map faults and to characterize geothermal systems, and measurements of atmospheric radon and radon daughter concentrations have been used to estimate the volume of magma chambers feeding active eruptions. Several studies have also shown that temporal variations in radon concentration have been associated with the onset of volcanic eruptions or changes in the rates or character of an eruption. Some of these studies have been able to clearly define the cause of the radon anomalies but others have proposed models of radon emission and transport that are not well supported by the known physical and chemical processes that occur in a volcanic system. In order to better characterize the processes that control radon activities in volcanic systems, it is recommended that future radon monitoring programs attempt to maintain continuous recording of radon activities; individual radon measurements should be made over the shortest time intervals possible that are consistent with acceptable counting statistics and geophysical, meteorological, and hydrological parameters should be measured in order to better define the physical processes that affect radon activities in volcanic systems. (author). 63 refs

  10. Comparative study of radon exposure in Canadian homes and uranium mines - a discussion on the importance of national radon program

    International Nuclear Information System (INIS)

    Chen, Jing

    2017-01-01

    The history of lung cancer in uranium miners is well known for over hundreds of years when the disease was referred to as 'miner's disease' or 'mountain sickness'. Radon levels in uranium mines have decreased significantly over the past 30 years as a result of effective radiation protection measures at workplaces. For the most recent 10-year period, the average radon concentrations to underground and surface workers in Canadian uranium mines were 111 and 11 Bq m -3 , respectively. Based on the recent radon survey carried out in roughly 14 000 homes in 121 health regions across Canada and the more recent radon and thoron survey in 33 Canadian cities and 4000 homes, the average radon concentration in Canadian homes is 77 Bq m -3 . This study demonstrates that, nowadays, workers are exposed to radon in underground mines at a comparable radon level to what Canadians are exposed to at home. Since exposure to indoor radon is the main source of natural radiation exposure to the population, it is important for the National Radon Program to further increase radon awareness, and to encourage more Canadians to take appropriate actions to reduce radon exposure. (authors)

  11. Radon as a groundwater tracer in Forsmark and Laxemar

    Energy Technology Data Exchange (ETDEWEB)

    Grolander, Sara

    2009-10-15

    Radon concentrations were measured in different water types in Forsmark and Laxemar during the site investigation and within this study. From these measurements it can be concluded that large differences between surface water, near surface groundwater and deep groundwater can be found in both Laxemar and Forsmark. The differences in radon concentrations between different water types are used in this study to detect interactions between surface water, near surface water and deep groundwater. From the radon measurements it can also be concluded that radon concentration in deep groundwater varies largely with depth. These variations with depth are probably caused by groundwater flow in conductive fracture zones in the bedrock. The focus of this study has been the radon concentration of near surface groundwater and the interaction between near surface groundwater and deep groundwater. Radon measurements have been done using the RAD-7 radon detector within this study. It could be concluded that RAD-7 is a good technique for radon measurements and also easy to use in field. The radon concentrations measured in near surface groundwater in Laxemar within this study were low and homogenous. The variation in radon concentration has been analyses and compared to other parameters. Since the hypothesis of this study has been that there are differences in radon concentrations between recharging and discharging groundwater, the most important parameter to consider is the recharge/discharge field classification of the wells. No correlation between the recharge/discharge classifications of wells and the radon concentrations were found. The lack of correlation between groundwater flow patterns and radon concentration means that it is not possible to detect flow patterns in near surface groundwater using radon as a tracer in the Laxemar area. The lack of correlation can be caused by the fact that there are just a few wells located in areas classified as recharge area. It can also be

  12. Procedure for the characterization of radon potential in existing dwellings and to assess the annual average indoor radon concentration

    International Nuclear Information System (INIS)

    Collignan, Bernard; Powaga, Emilie

    2014-01-01

    Risk assessment due to radon exposure indoors is based on annual average indoor radon activity concentration. To assess the radon exposure in a building, measurement is generally performed during at least two months during heating period in order to be representative of the annual average value. This is because radon presence indoors could be very variable during time. This measurement protocol is fairly reliable but may be a limiting in the radon risk management, particularly during a real estate transaction due to the duration of the measurement and the limitation of the measurement period. A previous field study defined a rapid methodology to characterize radon entry in dwellings. The objective of this study was at first, to test this methodology in various dwellings to assess its relevance with a daily test. At second, a ventilation model was used to assess numerically the air renewal of a building, the indoor air quality all along the year and the annual average indoor radon activity concentration, based on local meteorological conditions, some building characteristics and in-situ characterization of indoor pollutant emission laws. Experimental results obtained on thirteen individual dwellings showed that it is generally possible to obtain a representative characterization of radon entry into homes. It was also possible to refine the methodology defined in the previous study. In addition, numerical assessments of annual average indoor radon activity concentration showed generally a good agreement with measured values. These results are encouraging to allow a procedure with a short measurement time to be used to characterize long-term radon potential in dwellings. - Highlights: • Test of a daily procedure to characterize radon potential in dwellings. • Numerical assessment of the annual radon concentration. • Procedure applied on thirteen dwellings, characterization generally satisfactory. • Procedure useful to manage radon risk in dwellings, for real

  13. Measurements of radon in soil gas

    International Nuclear Information System (INIS)

    Paschuk, Sergei A.; Correa, Janine Nicolosi; Schelin, Hugo R.; Barbosa, Laercio; Sadula, Tatyana; Matsuzaki, Cristiana A.

    2009-01-01

    Full text: After the decades of systematic and numerous studies performed at different countries of the World, it has been concluded that radon as well as its progeny is the main cause of lung cancer. It is well known that more than 50% of the effective annual radiation dose received by a human being is related to the radon and its progenies. Among the principle mechanisms that bring the radon inside the dwelling is the soil exhalation as well as exhalation and release from the water. Radon concentration in the soil and its transport (emanation, diffusion, advection and adsorption) to the surface depends on different physical, geological and ambient parameters such as the geology of the area, geochemical composition of the soil, its porosity and permeability, grain size, soil humidity, bottom sediments and inputs from streams, temperature, atmospheric pressure, etc. Since the main part of indoor radon originates in the soil, the measurements of radon concentration in soil gas have to be considered as an important tool and indicator of probable high levels of radon inside the dwellings. Present work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222 Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. The equipment was adjusted with air flow of 0

  14. Concentraciones de DDT/DDE y riesgo de hipospadias: un estudio piloto de casos y controles

    Directory of Open Access Journals (Sweden)

    Flores-Luévano Silvia

    2003-01-01

    Full Text Available OBJETIVO: Evaluar la asociación entre los niveles séricos maternos de DDT/DDE y el riesgo de hipospadias. MATERIAL Y MÉTODOS: Estudio de casos y controles, efectuado en la Ciudad de México durante el periodo 1997-1999, con 41 casos de hipospadias y 28 controles. La informacion obtenida por cuestionario y las muestras sanguíneas fueron evaluadas mediante modelos multivariados de regresión logística. RESULTADOS: Las concentraciones materna de DDT y DDE no mostraron asociación con el riesgo de hipospadias (RM 1.13; IC 95% 0.24-5.29 y RM 0.48; IC 95% 0.15-1.60, respectivamente. Los predictores encontrados fueron hijos de madres con mayor edad (RM 8.69; IC 95% 1.69-44.9, y la actividad laboral durante el embarazo (RM, 4.68; IC 95% 1.15-18.9. CONCLUSIONES: Dado que se cuenta con escasa información sobre los efectos endocrinos a diferentes concentraciones de DDT/DDE en humanos, la dosis pudiera ser un factor determinante sobre el tipo de efecto.

  15. Radon - To mobilise civil society

    International Nuclear Information System (INIS)

    2016-01-01

    As radon is one of the two main sources of exposure of population to ionizing radiations in France, is notably said to be responsible of 1.000 to 3.000 deaths for lung cancer per year, and could be at the origin of other cancers like child leukaemia, this set of articles evokes the different factors which promote radon transfer from soils to buildings, studies performed to better identify geological sources of radon, actions implemented to assess radon presence in dwellings (distribution of 'radon kits' in Brittany), the performance of radiological expertise by the IRSN on the request of public authorities, the project of dwelling inventory and population information. A second article reports examples of intervention by the IRSN to inform local authorities, inhabitants, academics, public utilities, building professions, and even children. Technical solutions adopted in the United Kingdom are briefly evoked

  16. Radiation and Radon Survey of Akchatau (Khazakstan) and Experience with Radon Remedial Measures

    International Nuclear Information System (INIS)

    Soroka, Y.; Molchanov, A.

    1998-01-01

    A radiation survey of the territory of Akchatau settlement has been carried out. The main factors affecting the high content of radon in dwelling houses were revealed. The experiment on isolation of under floor spaces was carried out to prevent the entry of radon-containing soil gas into living rooms. The repair works efficiency for decreasing of the radon content in hazardous houses was analysed. The survey showed a need for regulation of the value of 222 Rn exhalation on the territories planned for construction works. (author)

  17. Disolución de sílice biogénica en sedimentos de lagos utilizados como bioindicadores de calidad del agua

    Directory of Open Access Journals (Sweden)

    Hermes U. Ramírez S.

    2007-01-01

    Full Text Available El objetivo de este trabajo es mostrar que la disoluci n de s lice amorfa de origen biog nico (diatomeas y fitolitos es un bioindicador de calidad del agua de lagos, valid ndose con la determinaci n de par metros f sico-qu micos. La determinaci n de diatomeas y fitolitos se realiz sobre n cleos de sedimentos del Lago Chapala, M xico. Las diatomeas y fitolitos fueron separados, depositados en laminillas y observados con microscop a de luz polarizada y electr nica de barrido. En forma paralela se analiz la calidad del agua del lago durante la d cada de 1990-2000 monitoreando 38 par metros f sicoqu micos en 25 estaciones. El estudio de diatomeas evidenci que la mayor a de ellos presentan fr stulas no preservadas, alto grado de disoluci n, fitolitos fragmentados y/o disueltos y una importante cantidad de debris de s lice. La determinaci n de fitolitos fue deficiente, con m s diatomeas en estado de disoluci n y debris de s lice opalino que fitolitos. Los resultados del an lisis f sico-qu mico del agua muestran valores de pH de 7,20-9,45, altas concentraciones de: nitr geno org nico (1,57 mg/l, nitr geno amoniacal (0,48 mg/l, nitratos (0,18 mg/l, f sforo org nico (0,16 mg/l, ortofosfatos (0,40 mg/l, f sforo total (0,57 mg/l y conductividad (867,53 S/cm lo que refleja altas concentraciones de sales, sobresaturaci n de CaCO3 con dureza total y c lcica de 221,35 y 142,67 mg/l respectivamente; alcalinidad total y c lcica de 307,29 y 29,90 mg/l respectivamente; todos factores que influyen en la disoluci n de diatomeas y fitolitos en los lechos del lago. Los resultados del estudio micropaleontol gico del Lago de Chapala han evidenciado disoluci n de diatomeas, fitolitos y la presencia de gran cantidad de debris de s lice amorfo y baja calidad de sus aguas, lo cual ha sido verificado con los par metros fisicoqu micos de la ultima d cada. Los fen menos de disoluci n de diatomeas y fitolitos por el momento son asociados a valores de pH>9, a condiciones eutr

  18. Radon and hydrotherapy: application to French spas

    International Nuclear Information System (INIS)

    Ameon, R.

    2004-01-01

    Owing to the use of thermal water for treatments, the dissolved radon ends up, through degassing, in the atmosphere of the various spa premises. According to the type of treatments, the radon activity concentration in the air is very variable; it depends on two factors, the supply of thermal water, and therefore of radon, and the ventilation of the various premises. In unfavourable, even non-existent, ventilation conditions, it is not uncommon to measure radon concentration reaching several thousands of becquerels per air cubic meter. These high values of radon activity concentration, with or without its short-lived daughters, may lead to a staff exposure of approximately ten or several tens of mSv per year. A French spa was subject to a radon 'expertise' during which the radon source terms, 'ground in contact with the buildings' and 'thermal water' were characterized. The radon mapping in the internal atmosphere of the various spa premises and the workstations' analysis resulted in an assessment of the exposure due to radon inhalation. This study showed that on workstations, notably linked to hydrotherapy, the staff exposure to radon is in the same range as the dose assessments from foreign studies. The implementation of an appropriate ventilation of the treatment rooms and a better management of the thermal water in the spa resulted in a significant reduction of staff exposure

  19. Third workshop on radon and radon daughters in urban communities associated with uranium mining and processing. Pt. 1

    International Nuclear Information System (INIS)

    1980-01-01

    This third meeting of Atomic Energy Control Board staff, contractors, federal and provincial government representatives, and delegates from outside Canada was held to discuss progress in reducing concentrations of radon and radon daughters in houses. Speakers talked about successful and unsuccessful remedial measures, methods of measuring and monitoring thoron and radon in houses, and indoor radon concentrations in Canada, Britain and Sweden

  20. Radon reduction in wood foundation system

    International Nuclear Information System (INIS)

    Clark, R.J.

    1990-01-01

    Radon, an issue of growing concern to the building industry. Silently, invisibly, it invades existing structures as it will future foundation structures. This paper addresses the nature and causes of radon, and cost-effective prevention and retrofit techniques used for wood foundation systems. Radon also can enter homes with foundations that use the under-floor as an air distribution system. These building practices will be shown; even materials used in construction may release radon, for example, this may be a problem in a house that has a solar heating system in which its heat is stored in large beds of stone. Stone is most often used in wood foundation construction. The common radon entry points will be looked at, and the latest prevention techniques will be illustrated, such as natural and forced ventilation, sealing major radon sources and entry routes, and sub-slab and sump crock ventilations

  1. Air pollution. Actions to promote radon testing

    International Nuclear Information System (INIS)

    Guerrero, Peter F.; Adams, Charles M.; McGee, William F.; Goldsmith, Larry A.; Feldesman, Alice G.; Grissinger, Charles R.; Updegraff, William D.; Langdon, Robin S.; Bartholomew, Philip L.

    1992-12-01

    To promote radon testing, EPA initiated public information and awareness programs and provided grants to states to develop programs aimed at encouraging homeowners to test for radon. Nationwide telephone surveys, according to EPA, indicate that these efforts have raised the public awareness of radon to as high as 78 percent but that about only 9 percent of those surveyed have tested their homes for radon. Concerned about improving risk reduction through its radon program, EPA convened a review panel. The panel not only recommended in May 1992 that the current voluntary approach be continued but also called for program changes to encourage more testing. These changes include targeting public information and other resources to areas where radon levels are predicted to be high and promoting testing and mitigation at the time of real estate transactions. To support state radon efforts, the Congress authorized a grant program for yearly grants of $10 million for 3 years. Funds for this program were recently extended for a fourth year through fiscal year 1993. Information to measure states' success in promoting testing by homeowners was generally not available because (1) much of the grant funding has been used to identify the extent of the radon problem; (2) federally funded public information projects were often directed to large audiences, making it difficult to measure testing rates; and (3) EPA's evaluation process for the grant program did not contain a component to measure increases in testing. We did, however, identify some state projects that have increased radon testing by targeting program efforts to homes in areas with potentially high levels of radon. The results of the state projects would seem to support the EPA review panel's recommendations on promoting radon testing through targeting program resources. In two states we surveyed, the voluntary use of disclosure statements as part of a real estate sales contract was a frequent occurrence, and in one state

  2. Radon in schools. An elevation measurement in schools in Baden-Wuerttemberg; Radon in Schulen. Eine Erhebungsmessung in Baden-Wuerttemberg

    Energy Technology Data Exchange (ETDEWEB)

    Fesenbeck, I.; Naber, C.; Frank, G.; Wilhelm, C.; Schaller, M. [Karlsruher Institut fuer Technologie (Germany). Sicherheit und Umwelt

    2016-07-01

    With an effective dose of about 1.1 mSv per year, radon and its secondary products have the biggest share in the population's natural radiation exposure. For implementation of the new EU directive 2013/59/EURATOM dated January 17, 2014, it is now planned to adapt the limit values of the Radiation Protection Ordinance and to extend the scope of validity in the EU member states. The ''Radon at Schools'' project is to cover an area-wide survey of radon concentrations in room air of schools in Baden-Wuerttemberg. Potential hazards caused by radon-222 and secondary products of radon are to be studied. For the project, 1600 schools were selected and requested to participate by an information letter. Half of the schools is distributed over the entire area of Baden-Wuerttemberg. The other half is located in areas of increased radon potential. Radon concentration in room air is determined passively by Karlsruhe radon exposimeters. Subsequently, active radon measurements will be made at conspicuous schools and information events will be offered for municipalities, teachers, interested parents, and pupils.

  3. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    International Nuclear Information System (INIS)

    George, A.C.; Knutson, E.O.; Tu, K.W.; Fisenne, I.M.

    1995-12-01

    The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC). There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is -3

  4. AZUDES Y ACUEDUCTOS DEL SISTEMA DE RIEGO TRADICIONAL DE LA VEGA BAJA DEL SEGURA (ALICANTE, ESPAÑA

    Directory of Open Access Journals (Sweden)

    Arturo Trapote Jaume

    2015-01-01

    Full Text Available En el presente trabajo se describen y analizan las principales obras hidráulicas del sistema de riego tradicional de la comarca de la Vega Baja del Segura, concretamente, los azudes y los acueductos. Los azudes de toma, construidos en el cauce del río Segura, representan el inicio del sistema, desde donde parte una extensa y compleja red de acueductos constituida por acequias y azarbes, como elementos fundamentales, que distribuyen el agua para el regadío. En este estudio se ha llevado a cabo una amplia y profunda investigación documental, tomado datos de campo y captado imágenes in situ que, junto con los diagramas aportados, resultan imprescindibles para comprender la magnitud del sistema. Los resultados obtenidos han servido no sólo para catalogar y caracterizar los elementos que integran el sistema hidráulico del regadío tradicional de la Vega Baja del Segura, sino también para poner de manifiesto un ejemplo real de optimización de recursos hídricos en una zona del sureste peninsular español de escasa e irregular pluviometría. Asimismo, el estudio efectuado revela un sistema de riego sumamente eficiente desde un punto de vista cuantitativo y no tanto desde el cualitativo, debido a la presencia, entre otros contaminantes, de altas concentraciones de sales.

  5. The Radon Book. Preventive measures in new buildings

    International Nuclear Information System (INIS)

    Clavensjoe, Bertil; Aakerblom, Gustav

    2004-01-01

    This book describes in text and picture how one can prevent that the radon concentrations in new buildings become to high. The book's centre of gravity lies on how to build in order to prevent that radon gas from the ground enters the building. The book contains extensive information about ground radon and how to examine the ground before constructing a new building. Release of radon from ground water and construction material is treated, as well as technology for measurement of radon and gamma radiation. The book presents current threshold values/recommended values for radon and the authorities' regulations and recommendations. The book is directed to persons who professionally need knowledge about radon and how to prevent that radon is accumulated in new buildings

  6. Radon: Not so Noble

    Indian Academy of Sciences (India)

    Radon in the Environment and Associated Health Problems ... is presently working on emission of ... Radon isotope 222 has a half-life of 3.8 days, long enough to ..... 222Rn concentration of one WL for 170 working hours in one month.

  7. γ-Ray spectrometry of radon in water and the role of radon to representatively sample aquifers

    International Nuclear Information System (INIS)

    Talha, S.A.; Lindsay, R.; Newman, R.T.; Meijer, R.J. de; Maleka, P.P.; Hlatshwayo, I.N.; Mlwilo, N.A.; Mohanty, A.K.

    2008-01-01

    Measurement of radon in water by γ-ray spectrometry using a HPGe detector has been investigated to determine aquifer characteristics. The radon activity concentration is determined by taking the weighted average of the concentrations derived from γ-ray lines associated with 214 Pb and 214 Bi decay. The role of accurate radon data to representatively sample aquifers was also investigated by studying a semi-cased borehole. A simplified physical model describing the change of radon concentration with the pumping time, reproduces the data and predicts the time for representative sampling of the aquifer

  8. Radon as a groundwater tracer in Forsmark and Laxemar

    International Nuclear Information System (INIS)

    Grolander, Sara

    2009-10-01

    Radon concentrations were measured in different water types in Forsmark and Laxemar during the site investigation and within this study. From these measurements it can be concluded that large differences between surface water, near surface groundwater and deep groundwater can be found in both Laxemar and Forsmark. The differences in radon concentrations between different water types are used in this study to detect interactions between surface water, near surface water and deep groundwater. From the radon measurements it can also be concluded that radon concentration in deep groundwater varies largely with depth. These variations with depth are probably caused by groundwater flow in conductive fracture zones in the bedrock. The focus of this study has been the radon concentration of near surface groundwater and the interaction between near surface groundwater and deep groundwater. Radon measurements have been done using the RAD-7 radon detector within this study. It could be concluded that RAD-7 is a good technique for radon measurements and also easy to use in field. The radon concentrations measured in near surface groundwater in Laxemar within this study were low and homogenous. The variation in radon concentration has been analyses and compared to other parameters. Since the hypothesis of this study has been that there are differences in radon concentrations between recharging and discharging groundwater, the most important parameter to consider is the recharge/discharge field classification of the wells. No correlation between the recharge/discharge classifications of wells and the radon concentrations were found. The lack of correlation between groundwater flow patterns and radon concentration means that it is not possible to detect flow patterns in near surface groundwater using radon as a tracer in the Laxemar area. The lack of correlation can be caused by the fact that there are just a few wells located in areas classified as recharge area. It can also be

  9. The use of radon as an earthquake precursor

    International Nuclear Information System (INIS)

    Ramola, R.C.; Singh, M.; Sandhu, A.S.; Singh, S.; Virk, H.S.

    1990-01-01

    Radon monitoring for earthquake prediction is part of an integral approach since the discovery of coherent and time anomalous radon concentrations prior to, during and after the 1966 Tashkent earthquake. In this paper some studies of groundwater and soil gas radon content in relation to earthquake activities are reviewed. Laboratory experiments and the development of groundwater and soil gas radon monitoring systems are described. In addition, radon monitoring studies conducted at the Guru Nanak Dev University Campus since 1986 are presented in detail. During these studies some anomalous changes in radon concentration were recorded before earthquakes occurred in the region. The anomalous radon increases are independent of meteorological conditions and appear to be caused by strain changes, which precede the earthquake. Anomalous changes in radon concentration before an earthquake suggest that radon monitoring can serve as an additional technique in the earthquake prediction programme in India. (author)

  10. Experience from using plastic film in radon measurement

    International Nuclear Information System (INIS)

    Joensson, G.

    1999-01-01

    Plastic film is a useful detector of radon gas. The method of detection of the gas is used for several decades to measure radon concentrations both indoors and in soil. Experiences from radon measurements in Sweden indoors, in soil and in water using the plastic film Kodak LR 115-II are discussed in this report. Some examples are given from various projects. One example is taken from a large scale mapping of indoor radon levels in houses, where the building material is the main source of radon. In another example the measurements from a large scale soil radon mapping are discussed. The use of the plastic film for measurements of radon levels in water is also discussed. All the investigations are made in order to give the authorities concerned information of the radon situation and to study the connection between high indoor radon levels and various types of cancers

  11. Radon Survey in Kalamata (Greece)

    International Nuclear Information System (INIS)

    Geranios, A.; Kakoulidou, M.; Mavroidi, Ph.; Moschou, M.; Fisher, S.; Burian, I.; Holecek, J.

    2001-01-01

    A national radon survey is still lacking for Greece. Some groups have carried out several more or less local or extended radon surveys and valuable experience has been gained. After the first preliminary survey carried out by our group, where 500 Kodak LR-115 etched track detectors were placed in Greek schools and dwellings for one year, indoor radon measurements were continued by placing the same number of detectors in a restricted area, covering the city of Kalamata (a medium size city with 60,000 inhabitants), situated in the south of Peloponnese. Although Kalamata was not of special radon interest, the local authorities insisted on knowing for their citizens' sake the level of this natural radiation. At first, the intention was to use a different method of organisation and distribution of the etched-track detectors from the previous one, attempting mainly to acquire more reliable results and to collect as many detectors as possible. Secondly, it was of great importance to test the statistics of the indoor radon concentrations for a rather small area, and thirdly, to estimate independently the annual absorbed dose by children, taking into account radon concentrations measured both in their home and at school. The set of detectors' readings (about 370), revealed, in general, lower values for Kalamata, compared to the ones found in the preliminary radon survey in Greece and almost all concentrations were found to be below the NRPB action level (200 Bq.m -3 ) (author)

  12. CARACTERIZACIÓN QUÍMICA Y OBTENCIÓN DE BIOETANOL DEL RESIDUO SÓLIDO DEL PROCESAMIENTO DEL ALMIDÓN DE YUCA

    Directory of Open Access Journals (Sweden)

    Maria Yahaira Marcillo Zambrano

    2012-12-01

    Full Text Available El objetivo del trabajo fue obtener bioetanol de los residuos del material lignocelulósico de la corteza de yuca (Manihot esculenta Crantz del procesamiento de almidón, en San Pablo de Tarugo, sometidos a pre tratamiento. Se hidrolizó el material con dos concentraciones de ácido muriático (75% y 100%, tres tiempos de reacción (20, 30 y 40 min a una temperatura de 60ºC en una relación peso – volumen 1/10. Se efectuó la identificación cualitativa (ensayo de lugol, Benedict y Fehling y cuantitativa de los azúcares reductores. Con los resultados obtenidos se logró determinar el mejor tratamiento según la cantidad de azúcares reductores mediante el análisis de varianza. Obteniéndose producción de azúcares reductores de 41.73 g/L por hidrólisis con ácido muriático al 100% y tiempo de reacción de 40 minutos, fermentándose con inóculo de 7 g/L de levadura comercial Levapan (Saccharomyces cerevisae a los 30 días se obtuvo 17ºGL.

  13. Determination of exhalation rate of radon from walls and indoor radon by CR-39 detectors

    International Nuclear Information System (INIS)

    Vasidov, A.; Tillaev, T.S.

    2007-01-01

    Full text: The knowledge of true value exhalation rate of radon gas from building materials represents scientific and practical interest in environmental radiation protection. This point of view in the paper exhalation rate of radon gas from building materials and a surface of walls with different constructions were determined by detectors CR-39. The values of the exhalation rate of radon per unit area of the granite, concrete, fired and unfired bricks, sand, cement, alabaster varied 0.091 - 0.1 Bq·m -2 ·h -1 . The surface of walls of dwellings constructed from different building materials the exhalation rate of radon are within in limits of 0.083-1.12 Bq·m -2 ·h -1 . Were measurements with CR-39 detectors a level of radon within 50-520 Bq/m 3 in air of rooms constructed of the different building materials

  14. Radon-hazard potential the Beaver basin, Utah

    International Nuclear Information System (INIS)

    Bishop, C.E.

    1995-01-01

    Indoor-radon levels in the Beaver basin of southwestern Utah are the highest recorded to date in Utah, ranging from 17.5 to 495 picocuries per liter (pCi/L). Because the U.S. Environment Protection Agency considers indoor-radon levels above 4 pCi/L to represent a risk of lung cancer from long-term exposure, the Utah Geological Survey is preparing a radon-hazard-potential map for the area to help prioritize indoor testing and evaluate the need for radon-resistant construction. Radon is a chemically inert radioactive gas derived from the decay of uranium-238, which is commonly found in rocks and soils. Soil permeability, depth to ground water, and uranium/thorium content of source materials control the mobility and concentration of radon in the soil. Once formed, radon diffuses into the pore space of the soil and then to the atmosphere or into buildings by pressure-driven flow of air or additional diffusion. The Beaver basin has been a topographic and structural depression since late Miocene time. Paleocene to Miocene volcanic and igneous rocks border the basin. Uraniferous alluvial-fan, piedmont-slope, flood-plain, and lacustrine sediments derived from the surrounding volcanic rocks fill the basin. A soil-gas radon and ground radioactivity survey in the Beaver basin shows that soils have high levels of radon gas. In this survey, uranium concentrations range from 3 to 13 parts per million (ppm) and thorium concentrations range from 10 to 48 ppm. Radon concentrations in the soil gas ranged from 85 to 3,500 pCi/L. The highest concentrations of uranium, thorium, and radon gas and the highest radon-hazard-potential are in the well-drained permeable soils in the lower flood- plain deposits that underlie the city of Beaver

  15. A study on the risk from indoor radon 220 and radon 222 exposures

    International Nuclear Information System (INIS)

    Rannou, A.

    1986-12-01

    The hazards from radon (radon 220 and 222) in dwelling atmospheres have been studied. In the first part devoted to the present state of the problem, an analysis is made of the formation mechanisms and the evolution of radon and its daughters indoors. The main physical and dosimetric quantities required for the risk evaluation are defined. The theoretical and experimental analysis of the methods of measurements of radon and its daughters used in the measurement campaign are considered in the second part. The progress and the result of the national survey are developed in the third part. The effects of several factors on indoor levels are discussed. The conclusions of a particular study in the Finistere ''department'' are presented. The data collected make it possible to assess the mean exposure of man to natural radiation [fr

  16. CUANTIFICACIÓN, CARACTERIZACIÓN Y COMPOSICIÓN DEL MATERIAL PARTICULADO 2,5, PROCEDENTE DEL USO DE LA COMBARBALITA

    Directory of Open Access Journals (Sweden)

    Ricardo Zamarreño

    2015-01-01

    Full Text Available En este trabajo, se muestran los resultados del material particulado P.M. 2,5 en la ciudad de Combarbalá, por la explotación y tallado de la “Combarbalita”. Los monitoreos se realizaron entre los meses de septiembre del 2010 y mayo del 2011. Determinando P.M. 2,5 con una bomba succionadora, cuantificando la concentración de algunos metales, utilizando espectroscopia de absorción atómica. Comprobando las características morfológicas de los componentes, usando la técnica de microscopia de inmersión. El promedio del PM 2,5 es de 22,50 μg/m3, estando bajo los valores recomendados por la EPA. Los elementos con mayores concentraciones son el Hierro, el Cobre, el plomo y el Zinc, el Cadmio posee la menor concentración. Las partículas de 2.5 μm y menores bordean el 36.11% del total analizado, las que tienen dimensiones de 4 a 10 μm suman el 50%. Concluyendo que Combarbalá posee bajos niveles de contaminación de material particulado P.M. 2,5.

  17. Study of the calibration of the medical physics department - radon dosimeter in a radon facility

    International Nuclear Information System (INIS)

    Nikololpoulos, D.; Louizi, A.; Papadimitriou, D.; Proukakis, C.

    1997-01-01

    Several techniques have been developed to measure radon indoors.The use of a Solid State Nuclear Track Detector closed in a cup, has turned out to be the most appropriate for long term measurements. The Medical Physics Department of the Athens University is carrying out radon measurements in dwellings, apartments, outdoor air and mines since 1996. For this purpose a simple device, the so called Medical Physics Department radon dosimeter, has been constructed, which measures the radon concentration averaged over a long period of time. In the present paper the calibration technique introduced and the results of the calibration of the Medical Physics Department. (authors)

  18. Effects of radon in indoor air studied

    International Nuclear Information System (INIS)

    Auvinen, A.

    1994-01-01

    Radon is an odorless, tasteless and colourless radioactive noble gas that enters indoor air from the ground. Radon causes lung cancer. A committee set up to evaluate the health risks of chemical substances has been drafting a report on radon, which will compile the major research findings on the lung cancer risk posed by radon. Animal tests have shown that even small doses of radon can cause lung cancer. Smokers seem to contract radon-induced lung cancer more readily than non-smokers. Because research findings have been conflicting, however, it is not known exactly how high the risk of lung cancer caused by indoor radon exposure really is. Several major research projects are under way to obtain increasingly accurate risk assessments. An on-going European joint project brings together several studies - some already finished, some still being worked on. In this way it will be possible to get more accurate risk assessments than from individual studies. In order to prevent lung cancer, it is important to continue the work of determining and reducing radon connects and to combat smoking. (orig.)

  19. Sources and protective measures of indoor radon

    International Nuclear Information System (INIS)

    Gou Quanlu; Wang Hengde

    1993-01-01

    This paper presents the relative contribution to indoor radon 222 Rn of various sources in twenty three rooms of three kinds in Taiyuan area. The results show that the major sources in this area are radon emanation from surfaces of soil and building materials and that from outdoor air, while the contribution of water and gas consumed in the rooms is less important. These results suggest a basis for taking suitable protective measures against indoor radon. Some materials are also recommended which are effective in restraining radon exhalation and low in price, by testing more than ten kinds of materials and comparing them using cost-effectiveness analysis technique, such as painting materials, polyvinyl alcohol (CH 2 :CHOH)n, etc. Their sealing effects on radon exhalation were examined with home-made REM-89 Radon Exhalation Monitor. The deposition effects of negative ion generator and humidifier on radon progeny were also tested. The maximum deposition may reach 70-90%, which proves they are also effective and economical in radon protection. (2 tabs., 3 figs.)

  20. Radon campaigns. Status report 2008; Radontalkoot. Tilannekatsaus 2008

    Energy Technology Data Exchange (ETDEWEB)

    Arvela, H.; Valmari, T.; Reisbacka, H.; Niemelae, H.; Oinas, T.; Maekelaeinen, I.; Laitinen-Sorvari, R.

    2008-12-15

    Radon campaigns aim at activating citizens to make indoor radon measurements and remediation as well as increasing the common awareness of indoor radon questions. Indoor radon increases the risk of lung cancer. Through radon campaigns Radiation and Nuclear Safety Authority (STUK) also promotes the attainment of those goals that the Ministry of Social Affairs and Health has set for municipal authorities in Finland for prevention of the harmful effects of radon. The Ministry of Social Affairs and Health supports this campaign. Radon campaigns were started in autumn 2003. By autumn 2008 the campaigns have been organised already in 64 regions altogether in 160 municipalities. In some municipalities they have already arranged two campaigns. Altogether 14 100 houses have been measured and in 2 100 of these the action limit of radon remediation 400 Bq / m3 has been exceeded. When participating in radon campaigns the house owners receive a special offer on radon detectors with a reduced price. In 2008 a new practice was introduced where the campaign advertisements were distributed by mail to low-rise residential houses in a certain region. The advertisement includes an order / deposit slip with postage paid that the house owner can send directly to STUK to easily make an order for radon measurement. In the previous radon campaigns in 2003 - 2007 the municipal authorities collected the orders from house owners and distributed later the radon detectors. The radon concentrations measured in the campaign regions have exceeded the action limit of 400 Bq / m3 in 0 - 39% of houses, depending on the region. The total of 15% of all measurements made exceeded this limit. The remediation activities have been followed by sending a special questionnaire on remedies performed to the house owners. In 2006 - 2007 a questionnaire was sent to those households where the radon concentration of 400 Bq / m3 was exceeded during the two first campaign seasons. Among the households that replied

  1. World Health Organization's International Radon Project 2005-2008

    International Nuclear Information System (INIS)

    Carr, Zhanat; Shannoun, Ferid; Zielinski, Jan M.

    2008-01-01

    Recent epidemiological studies of people exposed to indoor radon have confirmed that radon in homes is a serious health hazard that can be easily mitigated. To address the issue at an international level, the World Health Organization (WHO) established the International Radon Project (IRP). The project was launched in January 2005 with its first meeting attended by 36 experts representing 17 countries. The project's scope and the key objectives were outlined at this meeting and later refined: 1-) To identify effective strategies for reducing the health impact of radon; 2-) To promote sound policy options, prevention and mitigation programs (including monitoring and evaluation of programs; 3-) To raise public, political and economical awareness about the consequences of exposure to radon (including financial institutions as target group); 4-) To estimate the global health impact of exposure to residential radon using available data on radon worldwide. WHO and its member states strive through the WHO-IRP to succeed in putting indoor radon on the environmental health agenda in countries with lower awareness of radon as a health problem and in strengthening local and national radon-related activities in countries with ongoing radon programs. Two subsequent working meetings were held: in March, 2006 in Geneva with 63 participants from 25 countries, along with representatives of the International Atomic Energy Agency (IAEA), the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP), and European Commission (EC); and in March 2007 in Munich with 61 participants from 27 countries. Both meetings reviewed the IRP progress and focused on the two main outputs: 'The WHO Report on the Global Burden of Disease (GBD) due to Radon' and 'The WHO Radon Handbook'. The former applies the WHO methodology for GBD assessment and considers ways to graphically map residential radon concentrations

  2. Indoor Radon Exposure in Italian Schools

    Directory of Open Access Journals (Sweden)

    Antonio Azara

    2018-04-01

    Full Text Available Background: The aim of the study was to assess radon concentration in schoolrooms in a city located in the midwest of Italy. Methods: A two-phase environmental study was carried out in 19 school buildings of 16 primary, secondary, and tertiary schools. Results: Median (interquartile range—IQR indoor radon concentration in schoolrooms was 91.6 (45.0–140.3 Bq/m3. The highest (median 952.8 Bq/m3 radon concentration was found in one (3.6% classroom, located in a building of a primary school whose median concentration was 185 Bq/m3. Radon concentration was significantly correlated with the number of students and teachers, foundation wall construction material, and with the absence of underground floors. A geopedological survey was performed close to the building with highest radon level, showing the presence of granite and tonalithic granodiorite in the soil. Conclusions: Radon levels should be routinely assessed where individuals live or work. Schools are susceptible targets, because of childhood stay and the long daily stay of occupants. Low-cost interventions, such as implementation of natural air ventilation and school maintenance, can reduce radon levels, limiting individual exposure.

  3. Predicting radon flux from uranium mill tailings

    International Nuclear Information System (INIS)

    Freeman, H.D.; Hartley, J.N.

    1983-11-01

    Pacific Northwest Laboratory (PNL), under contract to the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) office, is developing technology for the design of radon barriers for uranium mill tailings piles. To properly design a radon cover for a particular tailings pile, the radon flux emanating from the bare tailings must be known. The tailings characteristics required to calculate the radon flux include radium-226 content, emanating power, bulk density, and radon diffusivity. This paper presents theoretical and practical aspects of estimating the radon flux from an uranium tailings pile. Results of field measurements to verify the calculation methodology are also discussed. 24 references, 4 figures, 4 tables

  4. Workshop on radon and radon daughters in urban communities associated with uranium mining and processing

    International Nuclear Information System (INIS)

    1978-01-01

    This meeting of Atomic Energy Control Board staff, representatives of other government departments, and consultants was called to exchange information on steps taken to lower radiation levels in houses in communities such as Elliot Lake, Uranium City, and Port Hope. Discussions covered the sources of radon and radon daughters in these houses, radon measurement techniques, and remedial methods that worked or were not successful

  5. Measurement of radon exhalation rate and soil gas radon concentration in areas of southern Punjab (Pakistan)

    International Nuclear Information System (INIS)

    Mujahid, S. A.; Hussain, S.; Ramzan, M.

    2010-01-01

    Plastic track detectors were used to measure the radon concentration and exhalation rate from the soil samples. The samples were collected from areas of southern Punjab (Pakistan). In a laboratory experiment, passive alpha dosemeters were installed inside cylindrical bottles containing the soil samples. The radon concentrations and the radon exhalation rate were found in the ranges of 34±7 to 260±42 Bq m -3 and 38±8 to 288±46 mBq m -2 h -1 , respectively. The on-site measurements of radon in the soil gas were also carried out in these areas using a scintillation alpha counter. The concentration of radon in the soil gas was found in the range of 423±82-3565±438 Bq m -3 . (authors)

  6. Environmental radon with RAD7 detector; Radon ambiental con detector RAD7

    Energy Technology Data Exchange (ETDEWEB)

    Lopez M, A.; Balcazar, M. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Fernandez G, I. M.; Capote F, E., E-mail: arturo.lopez@inin.gob.mx [Centro de Proteccion e Higiene de las Radiaciones, Carretera La Victoria II Km 2.5 e/ Monumental y Final, Guanabacoa, La Habana (Cuba)

    2016-09-15

    Experimental results of the radon detection with the equipment RAD7 are presented. The use of a solid state detector placed in a semi-spherical chamber with an electric field allows a high sensitivity of 0.4 cpm/P Ci/l. Radon detection is achieved by the spectroscopy of its decay products. In accordance with a table of errors for various ranges of counts and radon concentrations, reported by the manufacturer, an equation was obtained that allows establishing operation criteria of the equipment. For radon detection at ambient concentrations as low as 30 Bq m{sup -3}, is shown that short counts of 10 minutes are good enough to make decisions on radiation protection matter. In places where concentrations are close to 200 Bq m{sup -3}, counting intervals of the order of 0.5 hours will have an acceptable counting error of the order of 20%. The determination of radon in soil was, according to the expected, on the order of 10 kBq m{sup -3}, and was found that even with the recommended counting times of 5 minutes, there is a risk of increased humidity inside the detector above 20% Rh, with associated reduction of detection efficiency, if the desiccant is not used properly. The equipment was subjected to a radon exposure in air of 13, 373 Bq m{sup -3} ± 3.7%, contained within a controlled chamber, with a variation in temperature of (19-21) degrees Celsius and in the relative humidity of (5-7) %, the good stability of the chamber allows to propose calibration processes of these equipment s by assessing the concentration by means of a Ge (Hp) detector. (Author)

  7. Radiological risk assessment of environmental radon

    Energy Technology Data Exchange (ETDEWEB)

    Khalid, Norafatin; Majid, Amran Ab; Yahaya, Redzuwan; Yasir, Muhammad Samudi [Nuclear Science Programme, School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Darul Ehsan (Malaysia)

    2013-11-27

    Measurements of radon gas ({sup 222}Rn) in the environmental are important to assess indoor air quality and to study the potential risk to human health. Generally known that exposure to radon is considered the second leading cause of lung cancer after smoking. The environmental radon concentration depends on the {sup 226}Ra concentration, indoor atmosphere, cracking on rocks and building materials. This study was carried out to determine the indoor radon concentration from selected samples of tin tailings (amang) and building materials in an airtight sealed homemade radon chamber. The radiological risk assessment for radon gas was also calculated based on the annual exposure dose, effective dose equivalent, radon exhalation rates and fatal cancer risk. The continuous radon monitor Sun Nuclear model 1029 was used to measure the radon concentration emanates from selected samples for 96 hours. Five types of tin tailings collected from Kampar, Perak and four samples of building materials commonly used in Malaysia dwellings or building constructions were analysed for radon concentration. The indoor radon concentration determined in ilmenite, monazite, struverite, xenotime and zircon samples varies from 219.6 ± 76.8 Bq m{sup −3} to 571.1 ± 251.4 Bq m{sup −3}, 101.0 ± 41.0 Bq m{sup −3} to 245.3 ± 100.2 Bq m{sup −3}, 53.1 ± 7.5 Bq m{sup −3} to 181.8 ± 9.7 Bq m{sup −3}, 256.1 ± 59.3 Bq m{sup −3} to 652.2 ± 222.2 Bq m{sup −3} and 164.5 ± 75.9 Bq m{sup −3} to 653.3 ± 240.0 Bq m{sup −3}, respectively. Whereas, in the building materials, the radon concentration from cement brick, red-clay brick, gravel aggregate and cement showed 396.3 ± 194.3 Bq m{sup −3}, 192.1 ± 75.4 Bq m{sup −3}, 176.1 ± 85.9 Bq m{sup −3} and 28.4 ± 5.7 Bq m{sup −3}, respectively. The radon concentration in tin tailings and building materials were found to be much higher in xenotime and cement brick samples than others. All samples in tin tailings were exceeded the

  8. Radon studies in selected workplaces

    International Nuclear Information System (INIS)

    Randle, M.W.

    2000-01-01

    Radon progeny levels were measured in coal mines, a hard rock mine and two underground hydro power stations, to indicate if there is a health problem associated with exposure to radon and radon progeny in these workplaces. The average alpha concentrations ranged from 37 to 276 Bq m -3 , with the highest levels being found in a mine with no ventillation that was being decommissioned. Average dosages were calculated to be 0.1 - 0.7 mSv y -1 . Radon progeny levels in coal mines measured in the return air circuit are indicative of levels to which a worker at the face would be exposed. They were well below international guidelines for intervention in New Zealand mines, as were the slightly higher levels in two underground hydro power stations. These results confirm that radon levels in New Zealand are low. Even in the extreme situation represented by the Sullivan mine with no ventillation the levels do not warrant concern. 11 refs., 2 tabs

  9. Study of underground radon transport

    International Nuclear Information System (INIS)

    Csige, I.; Hakl, J.; Lenart, L.

    1990-01-01

    The soil gas radon content measurements with solid state nuclear track detectors (SSNTDs) are widely used in geoscience, for instance in uranium exploration and earthquake prediction. In these applications the radon frequently is used as a natural tracer of underground fluid transport processes. Obviously, to get the soil radon measuring method more and more effective the study of these transport processes in deeper part of the Earth is fundamental. The Track Detector Group in the Institute of Nuclear Research of the Hungarian Academy of Sciences in Debrecen has been performing environmental radon activity concentration measurements since 1977 with alpha sensitive SSNTDs. These types of measurements were initiated and widely used by the late head of the group Dr. G. Somogyi, who devoted his life to better understanding of the nature. The measurements in caves, springs and drilled wells proved to be effective to study these underground radon transport processes. We are glad to present some results of our investigations. 7 refs, 7 figs

  10. Radiometers for radon concentration in air

    International Nuclear Information System (INIS)

    Bartak, J.; Machaj, B.; Pienkos, J.P.

    2002-01-01

    Constant grow of science and technology stimulates development of new improved measuring tools. New measuring demand arise also in radon concentration measurements. Varying rock stress and rock cracks influencing radon emanation encouraged research aimed at use of this phenomenon to predict crumps of mine formation among others based on variation of radon emanation. A measuring set was developed in the Institute of Nuclear Chemistry and Technology enabling long term monitoring of radon concentration in mine bore-hole. The set consists probe and probe controller. Detection threshold of the probe is 230 Bq/m 3 . The set can operate in the environment with methane explosion hazard. A radiometer employing Lucas cell as radiation detector for radon concentration in air was also developed its detection threshold is approx. 10 Bq/m 3 . Replaceable Lucas cell of the radiometer allows for measurement of high as well as low radon concentration in short time interval. (author)

  11. Radon activities in natural gases

    International Nuclear Information System (INIS)

    Sajo, B.L.; Palfalvi, J.

    1995-01-01

    Radon activities have been measured in gas samples used for residential heading, in Venezuela and in Hungary. Gas bottles were selected randomly in different regions, and radon activities were monitored with ionization clambers and solid stoke track detections. Radon concentrations in household natural gas are presented for regions in Venezuela and in Budapest, Hungary. The latter was found to be in the range of 88-135 Bq/m 3 . (R.P.)

  12. Smoking cessation programmes in radon affected areas: can they make a significant contribution to reducing radon-induced lung cancers?

    International Nuclear Information System (INIS)

    Denman, A.R.; Groves-Kirkby, C.J.; Timson, K.; Shield, G.; Rogers, S.; Phillips, P.S.

    2008-01-01

    Domestic radon levels in parts of the UK are sufficiently high to increase the risk of lung cancer in the occupants. Public health campaigns in Northamptonshire, a designated radon affected area with 6.3% of homes having average radon levels over the UK action level of 200 Bq m -3 , have encouraged householders to test for radon and then to carry out remediation in their homes, but have been only partially successful. Only 40% of Northamptonshire houses have been tested, and only 15% of householders finding raised levels proceed to remediate. Of those who did remediate, only 9% smoked, compared to a countywide average of 28.8%. This is unfortunate, since radon and smoking combine to place the individual at higher risk by a factor of around 4, and suggests that current strategies to reduce domestic radon exposure are not reaching those most at risk. During 2004-5, the NHS Stop Smoking Services in Northamptonshire assisted 2,808 smokers to quit to the 4-week stage, with some 30% of 4-week quitters remaining quitters at 1 year. We consider whether smoking cessation campaigns make significant contributions to radon risk reduction on their own, by assessing individual occupants' risk of developing lung cancer from knowledge of their age, gender, and smoking habits, together with he radon level in their house. The results demonstrate that smoking cessation programmes have significant added value in radon affected areas, and contribute a greater health benefit than reducing radon levels in the smokers' homes, whilst they remain smokers. Additionally, results are presented from a questionnaire-based survey of quitters, addressing their reasons for seeking help in quitting smoking, and whether knowledge of radon risks influenced this decision. The impact of these findings on future public health campaigns to reduce the impact of radon and smoking are discussed. (author)

  13. Carcinogenic risk associated with radon-enriched well water

    International Nuclear Information System (INIS)

    Mose, D.G.; Mushrush, G.W.

    1997-01-01

    A comparison has been made between radon in drinking water and the incidence of cancer using a set of home occupants in Virginia and Maryland. In a subset of people who drink radon-free but chlorinated drinking water from a reservoir, about 3% develop some type of cancer. In a subset of people who drink low-radon water from private water wells, about 3% develop cancer. In a subset who drink high-radon well water, about 6% develop cancer. A comparison with Environmental Protection Agency (EPA) estimates of cancer related to airborne radon indicates that for the general population, the incidence of radon-related cancer from drinking water is similar to the incidence of cancer from inhaled radon. For the 10% of the population that consumes well water and, in particular, for the 5% of the population that consumes high-radon well water, the drinking water carries a considerably higher cancer risk than inhaling airborne radon

  14. The finnish guide to radon-resistant homes

    International Nuclear Information System (INIS)

    Arvela, H.

    2006-01-01

    Full text of publication follows: New regulations of the National Finnish Building Code require consideration of radon risks and as a main rule radon technical design in the building permission documents. Slab-on-grade is the prevalent substructure in Finnish low-rise residential buildings. Building statistics show that the prevalent practices in foundation construction promote the flow of radon-bearing soil air into living spaces. Without prevention the normal practices would result in high indoor radon concentrations in Finland. In wide areas more than 50% of houses exceed the reference level of 200 Bq/m 3 given for new buildings. The new guide published in 2003 requires installation of protective sheet in the slab-on-ground foundation and a preparatory radon piping. A protective sheet of durable reinforced bitumen felt with a width of 50 - 100 cm should be installed in the slab-foundation wall joint. Careful sealing of lead-troughs plays also an important role. In the case the sealing work does not result in low indoor radon concentration, the radon piping should be activated through radon-fan installation. Careful implementation of the sealing work reduces indoor radon concentration to a level of less than 50 Bq/m 3 , also in areas where the normal building practices result in indoor radon concentrations exceeding the reference level of 200 Bq/m 3 in more than 50% of new houses. Recent experiences from the implementation of the guide will be considered. (author)

  15. Seasonal Variability in European Radon Measurements

    Science.gov (United States)

    Groves-Kirkby, C. J.; Denman, A. R.; Phillips, P. S.; Crockett, R. G. M.; Sinclair, J. M.

    2009-04-01

    In temperate climates, domestic radon concentration levels are generally seasonally dependent, the level in the home reflecting the convolution of two time-dependent functions. These are the source soil-gas radon concentration itself, and the principal force driving radon into the building from the soil, namely the pressure-difference between interior and exterior environment. While the meteorological influence can be regarded as relatively uniform on a European scale, its variability being defined largely by the influence of North-Atlantic weather systems, soil-gas radon is generally more variable as it is essentially geologically dependent. Seasonal variability of domestic radon concentration can therefore be expected to exhibit geographical variability, as is indeed the case. To compensate for the variability of domestic radon levels when assessing the long term radon health risks, the results of individual short-term measurements are generally converted to equivalent mean annual levels by application of a Seasonal Correction Factor (SCF). This is a multiplying factor, typically derived from measurements of a large number of homes, applied to the measured short-term radon concentration to provide a meaningful annual mean concentration for dose-estimation purposes. Following concern as to the universal applicability of a single SCF set, detailed studies in both the UK and France have reported location-specific SCF sets for different regions of each country. Further results indicate that SCFs applicable to the UK differ significantly from those applicable elsewhere in Europe and North America in both amplitude and phase, supporting the thesis that seasonal variability in indoor radon concentration cannot realistically be compensated for by a single national or international SCF scheme. Published data characterising the seasonal variability of European national domestic radon concentrations, has been collated and analysed, with the objective of identifying

  16. Radon and its importance for animal hygiene

    International Nuclear Information System (INIS)

    Janowski, T.M.; Tombarkiewicz, B.

    1995-01-01

    Reconnaissance studies on radon concentration were carried out for various species of animal in animal housing in the Cracow region. It was found that the level of radon inside the livestock houses depended on the type of housing and animal species. In a cow shed the concentration of radon was higher by 25% than in the atmosphere, whereas in a piggery the radon level exceeded twice that in the ambient air. However, in a poultry house the radon concentration was over 20% lower then outside. (author). 9 refs

  17. Ethanol as radon storage: applications for measurement

    International Nuclear Information System (INIS)

    Winter, I.; Philipsborn, H. von

    1997-01-01

    Ethanol as Radon Storage: Applications for Measurement Ethanol has a solubility for radon of 6 Bq/l per kBq/m 3 air, 24 times higher than water. On filtration of ethanol, radon decay products are completely adsorbed on glass fiber filters, as previously reported for water. Hence: 1. A new simple method for measuring radon in soil air, without expensive equipment. 2. The production of mailable radon calibration sources ('radonol') with 50-100 kBq/l in PET-bottles with 3.8 days half-life, using uraniferous rocks as primary source. (orig.) [de

  18. Radon investigations - Soil and commercial projects

    International Nuclear Information System (INIS)

    Goodwin, R.W.

    1987-01-01

    The liability issues of radon exposure have prompted potential purchasers of vacant land for commercial/industrial development, and commercial landlords, renting large commercial buildings, to determine the radon gas levels at such sites. This paper deals with both pre-construction sites subject to freezing conditions and to large commercial structures. A correlation of radon gas levels within a commercial building and a sister pre-construction site confirms the validity of using activated charcoal canisters as a cost effective means to combating radon in large structures

  19. Radon barrier: Method of testing airtightness

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Buch-Hansen, Thomas Cornelius

    2017-01-01

    The test method NBI 167/02 Radon membrane: Test of airtightness can be used for determining the airtightness of a radon barrier as a system solution. The test determines the air infiltration through the radon barrier for a number of levels of air pressure differences. The airflow through versus...... of the barrier with the low air pressure, through a well-defined opening, as a modification of the test method in general. Results, obtained using the improved test method, are shown for a number of radon barriers tested....

  20. Radon: implications for the health professional

    International Nuclear Information System (INIS)

    Romano, C.A.

    1990-01-01

    Radon is a colorless, odorless gas formed by radioactive decay of radium and uranium, which are naturally present in the earth's crust. When concentrated indoors, this invisible gas becomes a potential health hazard. The Environmental Protection Agency estimates that up to 20,000 lung cancer deaths annually can be attributed to prolonged radon exposure. Radon is an important health issue that should be understood by all health care professionals. This paper discusses some of the important issues regarding radon, such as the incidences of lung cancer believed to be attributable to radon, the high-risk areas in the United States, federal safety guidelines, and public apathy. These issues and their impact on the health care required by professionals, especially nurse practitioners, are discussed

  1. Metrology of radon and thoron concentrations

    International Nuclear Information System (INIS)

    Durcik, M; Vicanova, M.

    1998-01-01

    The alpha spectrometry measurements of radon (radon-222) and thoron (radon-220) concentrations by ionisation chamber, used only in laboratory conditions are described in this paper. For the measurements of radon and thoron in dwellings and work areas was proposed diffusion double chamber detector with track detector. The described dosimeter is very useful for routine measurement and would be applied in measuring of radon and thoron concentrations in caves and dwellings. Big disadvantage of the dosimeter is small holes in cover and it could not be used in dusty areas. From previous measurements of the equilibrium equivalent thoron concentrations by semiconductor detector the measured values ranged from 0.1 to 5.6 Bq m -3 in the Slovak kindergartens were obtained

  2. Radon therapy in the Soviet Union

    International Nuclear Information System (INIS)

    Sansoni, B.; Andrejew, S.V.

    1991-08-01

    In the Soviet Union approximately one million courses of radon treatment each lasting three weeks are prescribed every year. The curative application of radon used for cardiovascular diseases, including aftercare in cases of cardiac infarction, disorders of the locomotor system and joints and muscles, the male and female sexual system, diseases of the nervous system, endocrinology and metabolic diseases. Contraindication practice is similar to that in Central Europe. Radon is given to skin stimulation by wet and above all dry baths. The radiation exposure of patients from these three-week radon treatments is relatively low. The radon effect is interpreted as 'radiation flash' stimulating the nervous system. The skin plays a particular role in this process, acting as the stimulus acceptor. (orig./MG) [de

  3. Design, construction and testing of a radon experimental chamber; Diseno, construccion y pruebas de una camara experimental de radon

    Energy Technology Data Exchange (ETDEWEB)

    Chavez B, A; Balcazar G, M

    1991-10-15

    To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact it was coupled and proved a new automatic exchanger system of passive detectors of radon. The results of the new automatic exchanger system when it leave to flow the radon freely among the container and the automatic exchanger through a plastic membrane of 15 m. are shown. (Author)

  4. Radon gas measurement in Corum

    International Nuclear Information System (INIS)

    Uzbey, S.; Celebi, N.

    2009-01-01

    The existence of the natural radioactive sources in earth's crust which has long half-life and the degradation products of these in the environmental medium such as earth, rocks, foods, water, air, forms the basis of radiation which people are exposed to. Radon is the unique radioactive gas in the nature and it is made up of radium which is the result of uranium degradation. It is necessary to determine the radon concentration because of the difference in the concentration of uranium existence in different places. TAEK (Turkish Atomic Energy Authority) allows 400 Bq/m 3 of radon concentration at houses, 1000 Bq/m 3 at offices per year. In this attempt, government buildings, houses and offices were determined as the sampling places in Corum city center and towns to represent Corum. While disposing the radon measuring detectors, places which are close to the ground level were preferred. 74 radon detectors were left in those places for 60 days and in the end the detectors were collected while discontinuing the connection of environment and they were assessed. According to the results, the average radon gas concentration in 14 government buildings is 71,71 Bq/m 3 , in 15 offices 32,26 Bq/m 3 and at houses 42,34 Bq/m 3 .

  5. Radon affected areas: Scotland

    International Nuclear Information System (INIS)

    Miles, J.C.H.; Green, B.M.R.; Lomas, P.R.

    1993-01-01

    Board advice on radon in homes issued in 1990 specifies that areas of the UK where 1% or more of homes exceed the Action Level of 200 becquerels per cubic metre of air should be regarded as Affected Areas. Results of radon measurements in homes in the districts of Kincardine and Deeside and Gordon in Grampian Region and Caithness and Sutherland in Highland Region are mapped and used to delineate Affected Areas in these areas where required. The Scottish Office is advised to consider the desirability of developing guidance on precautions against radon in future homes. (author)

  6. Relaciones suelo-vegetación en una toposecuencia del Escudo Guayanés, Venezuela

    Directory of Open Access Journals (Sweden)

    José Rafael Lozada

    2014-03-01

    Full Text Available El Escudo Guayanés es uno de los territorios más antiguos del planeta; tiene millones de años sometido a procesos de lixiviación y erosión que dejan suelos oligotróficos. El objetivo de este trabajo fue hacer la caracterización de los parámetros físicos y químicos de los suelos, en diferentes comunidades boscosas de la Reserva Forestal Imataca, e identificar ciertas relaciones entre los componentes edáficos y las especies que allí se presentan. Se realizó un inventario de todos los individuos mayores a 10cm dap (diámetro a la altura del pecho en 15 parcelas (1ha; en cada una de esas parcelas se evaluaron cuatro sub-parcelas de sotobosque (100m² para contabilizar todas las espermatofitas; los suelos se evaluaron mediante una calicata por comunidad y un barreno en cada sub-parcela de sotobosque. La mayoría de los suelos tienen un pH muy ácido (3.1-4.5, los nutrientes están en concentraciones muy bajas (N: 0-0.2%; P: 0-14ppm; K: 0-0.3Cmol/kg y el Al en concentraciones tóxicas. Esto coincide con otros estudios realizados en esta región, pero en este trabajo se encontró que la relación Ca/Al con valores superiores a 1, lo que implica una neutralización del efecto tóxico del Al y permite un mejor desarrollo de las comunidades boscosas.

  7. Radon in Norwegian dwellings

    International Nuclear Information System (INIS)

    Strand, T.; Green, B.M.R.; Lomas, P.R.

    1992-01-01

    The results of a large-scale survey of radon concentrations in Norwegian dwellings are reported. Measurements of radon have been made in a total of 7500 dwellings. The dwellings were randomly selected and the number in each municipality is proportional to its population. The measurements were performed using etched track detectors from the National Radiological Protection Board in the UK. One detector was placed in the main bedroom in each dwelling for 6 months. The annual average of radon concentration in Norwegian bedrooms is calculated to be 51 Bq.m -3 . The frequency distribution is approximately log-normal with a geometric mean of 26 Bq.m -3 and about 4% of the bedrooms have concentrations above 200 Bq.m -3 . The radon concentrations are found to be about 40% higher for bedrooms in single-family houses than in blocks of flats and other multifamily houses. In a large proportion of single-family houses the living room and the kitchen are located on the ground floor and the bedrooms on the first floor. An additional factor is that the winters of 1987-1988 and 1988-1989 were much warmer than normal. Taking these factors into account, the average radon concentration in Norwegian dwellings is estimated to be between 55 and 65 Bq.m -3 . (author)

  8. Indoor radon level in schools of Shillong, Meghalaya

    International Nuclear Information System (INIS)

    Saxena, A.; Sharma, Y.; Maibam, D.; Walia, D.; Diengdoh, E.

    2010-01-01

    Radon ( 222 Rn) in the atmosphere is the most important contributor to human exposure from natural sources. Radon is a noble inert gas; and it decays to radionuclides that are chemically active and relatively short lived. Inhalation of the short lived radon progeny imparts a radiation dose to the lung, to which an increased risk of lung cancer is attributed due to the alpha particle irradiation of the secretory and basal cells of the respiratory tract. The indoor radon concentration is dependent on the texture, porosity, permeability, water content of the soil underlying the structure and the radon behaviour in soils on aspects of geology and climate. The direct cause of high radon entry rates into structures exhibiting high indoor radon concentrations are fractures in bedrock formations, cracks in the soil, and similar inhomogeneities in the materials of the foundation of the structures. Other factors influencing indoor radon concentration includes exhalations from the walls and ceilings, building design and material, cracks and openings in the foundation of the buildings. The geological factors in the study area promote radon accumulation especially in buildings and dwellings. The world average annual effective dose in the indoor environments is 1.01 mSv.y -1 . The importance of radon level measurements in school buildings is of interest as children are more sensitive to radon exposure than adults. Hence, radon measurements in 10 schools have been undertaken in the present study

  9. Psychosocial aspects of Czech Radon Programme

    International Nuclear Information System (INIS)

    Fojtikova, I.; Neznal, M.; Hrdy, L.

    2004-01-01

    In November 1999 a radon awareness survey was conducted among Czech republic residents to evaluate their general awareness and the factual knowledge about radon, radon measurements and radon mitigation. This survey, however, did not provide any detailed information on whether the respondents' knowledge is deep and structured or it is just a chaotic mixture of impressions. Therefore, a new survey was conducted from May to November 2001. About 20 respondents, in whose houses the long term testing for radon levels had just been finished, were interviewed. The in-depth interviews had several main aims: a) to obtain a more detailed understanding of their general awareness and factual knowledge about radon; b) to learn more about the sources of their knowledge and of their perception of the radon risk; c) to get information as to whether householders accept radon remediation, and to identify any personal, attitudinal or other variables that can influence the householder's decision; and d) to experience the direct risk communication and conceive its effectiveness. The interviews confirmed some results of the former quantitative study, e.g. increasing knowledge correlating with increasing education level. They showed that the public, overloaded with information, is not disposed to search actively for other information sources (e.g. on the Internet). People perceive their knowledge as adequate and sufficient. Their approach to gathering information is very passive. Therefore, to enhance public understanding of radiation phenomena it is necessary to make efforts, including the use of public media, otherwise radioactivity will remain shrouded in myths. These myths often lead to underestimation of the radon risk. A typical example of such underestimation is a contention that there exist long-aged healthy people who live in extreme radon concentrations. Together with the interviews, a questionnaire describing 11 presumably risky situations or practices was used. Among other

  10. Radon concentration of waters in Greece and Cyprus

    Science.gov (United States)

    Nikolopoulos, D.; Vogiannis, E.; Louizi, A.

    2009-04-01

    Radon (222Rn) is a radioactive gas generated by the decay of the naturally occurring 238U series. It is considered very important from radiological point of view, since it is the most significant natural source of human radiation exposure (approximately 50% from all natural sources). Radon is present in soil, rocks, building materials and waters. Through diffusion and convection, radon migrates and emanates to the atmosphere. Outdoors, radon concentrates at low levels (in the order of 10 Bq/m3). However indoors, radon accumulates significantly. It is trivial to observe indoor environments with high radon levels (in the order of 400 Bq/m3 or higher). Radon accumulation indoors, depends on the composition of the underlying soil and rock formation, on building materials, meteorological parameters, ventilation, heating and water use. Although soil and building materials are the most significant radon sources, there have been reported elevated radon concentrations in building structures due to entering water. It is the radon concentrations in the entering water, the volume and the way of water usage, separated or in combination, that result in large amounts of radon in indoor air. Moreover, radon is a factor of stomach radiation burden due to water consumption. This burden is estimated by measurements of radon concentrations in waters. Due to the health impact of radon exposure, the reporting team continuously measures radon. This work focused on the radon concentrations exposure due to water consumption and use in Greece and Cyprus. Various locations in Greece and Cyprus were accessed taking into consideration existing natural radioactivity data (mainly radon in water), however under the restriction of the capability of movement. Radon in water was measured by Alpha Guard (Genitron Ltd) via a special unit (Aqua Kit). This unit consists of a vessel used for forced degassing of radon diluted in water samples, a security vessel used for water drop deposition. Vessels and

  11. Radon diagnostics and tracer gas measurements

    International Nuclear Information System (INIS)

    Jilek, K.; Brabec, M.

    2004-01-01

    An outline is presented of the tracer gas technique, which is used for continuous measurements of air ventilation rate (generally time-varying) and for simultaneous estimation of air ventilation rate and radon entry rate, and some of its limitations are discussed. The performance of this technique in the calculation of the air ventilation rate is demonstrated on real data from routine measurements. The potential for air ventilation rate estimation based on radon measurements only is discussed. A practical application is described of the tracer gas technique to a simultaneous estimation of the air ventilation rate and radon entry rate in a real house where the effectiveness of radon remedy was tested. The following main advantages of the CO tracer gas techniques are stressed: (i) The averaging method continuous determination of the ventilation rate with good accuracy (≤ 20 %). (ii) The newly presented and verified method based on simultaneous measurements of radon concentration and CO gas concentration enables separate continuous measurements of the radon entry rate and ventilation rate. The results of comparative measurements performed with the aim to estimate the inaccuracy in determination of radon entry rate showed acceptable and good agreement up to approximately 10 %. The results of comparative measurements performed with the aim to estimate the mutual commensuration of the method to the determination of the ventilation rate confirmed the expected unreliability the two parametric non-linear regression method, which is the most frequently used method in radon diagnostic in the Czech Republic

  12. Control borroso para la valoración del impacto ambiental generado por contaminantes emergentes en aguas residuales hospitalarias

    Directory of Open Access Journals (Sweden)

    Leadina Sánchez Barboza

    2015-06-01

    Full Text Available La valoración de impactos ambientales está sujeta a imprecisión, vaguedad y subjetividad. Estas características son extensivas al impacto generado por la presencia de contaminantes emergentes -fármacos- en aguas residuales hospitalarias, por lo que este trabajo propone valorar el impacto de dichos contaminantes mediante un sistema de inferencia borrosa, utilizando el toolbox fuzzy logic de MATLAB®, aplicando el sistema experto Mamdani. Los conjuntos borrosos de entrada se establecieron a partir de las concentraciones de los fármacos mediante variables lingüísticas definidas por medio de funciones de pertenencia trapezoidales, y el conjunto borroso de salida comprende la magnitud del impacto definida a través de una función de pertenencia triangular. Posteriormente, se obtuvo una valoración (en escala de 0 a 100 para concentraciones de fármacos máximas y promedios presentes en el agua residual, y por último, con estos valores se determina la magnitud del impacto ambiental a través del sistema de inferencia borrosa diseñado. El tratamiento borroso es útil para valorar los impactos ambientales en aguas residuales de contaminantes emergentes como los compuestos farmacéuticos.

  13. Radon exposures in the UK

    International Nuclear Information System (INIS)

    O'Riordan, M.C.

    1992-01-01

    Public and occupational health protection against radon is provided in the UK. Protection is advised where geological conditions cause high concentrations in domestic and commercial buildings. These circumstances are described and the resulting exposures reviewed. An account is given of the limitation scheme for radon in the home and the regulatory scheme for radon at work, the manner in which they are implemented, and the degree to which they are successful. (author)

  14. The Department of Energy's radon testing program

    International Nuclear Information System (INIS)

    Scott, H.L.; Dudney, C.S.; Wilson, D.L.; Gammage, R.B.

    1993-01-01

    The US Department of Energy recently completed an initial survey of indoor radon in its buildings in response to Public Law 100--551, the Indoor Radon Abatement Act of 1988. Other federal agencies have also conducted radon surveys. This paper presents an overview of the results from radon testing of several thousand buildings ranging from 100 m 2 to over 10,000 M 2 in size. In addition, we have examined results from groups of buildings, classified according to ventilation and usage characteristics. So far, there is no apparent difference among building classes. The paper also discusses our proposal for phased radon surveys. We suggest that first-phase results can be used to identify facilities with radon problems. In the second phase, we suggest measurements be made at a much higher sampling density at facilities with radon problems. The results of the second phase are expected to identify all buildings in need of mitigation

  15. Interaction of radon progeny with atmospheric aerosols

    International Nuclear Information System (INIS)

    Morawska, Lidia

    1994-01-01

    The radiological health hazard due to the airborne radon progeny depends on three factors (i) radon concentration in the air, (ii) radon progeny concentration, and (iii) active particle size distribution. Conclusions as to the health hazard cannot be drawn without full understanding of the interaction mechanisms between radon progeny and atmospheric aerosols. The aim of this work was to study the interaction mechanisms between radon progeny, natural environmental aerosols and environmental tobacco smoke (ETS). The experiments were performed under controlled laboratory conditions of radon concentration (1.85 and 3.70 Bq m -3 ), relative humidity (35, 50, 75 and 95%) and ETS generation. The size distribution of radioactivity carrying aerosols was measured using a wire screen diffusion battery system and size distribution of all airborne aerosols using a differential mobility particle sizer. The paper presents and discusses the results of activity size distribution and radon progeny concentration measurements for different environmental conditions. 7 refs., 2 tabs

  16. The control of radon levels in houses

    International Nuclear Information System (INIS)

    Al-Jarallah, M. B. I.

    2007-01-01

    The article speaks about radon entry ways to houses, the technologies of controlling the level of radon in indoors and four possible ways to solve the problem of high concentration of radon gas in housing and protection from being gathered to a certain extent that is harmful to health. These methods are: removal of the radon source, modifying the radon source, ventilation and air filtration. The article also addresses the impact of reducing the consumption of heating energy in homes and buildings using thermal insulators in floors, walls, ceilings and doors and making double glazed windows that confine the air. It has been proven that there is a steady relationship between energy conservation measures in housing and the increase of radon concentration by two to three times. In a lot of buildings, where conservation measures have been taken, materials to conserve heat are used, which themselves launch radon and this may lead to increased levels of the gas in the housing.

  17. A law of removing radon by ventilation and air requirement calculation for eliminating radon daughters in uranium mines

    International Nuclear Information System (INIS)

    Wu Gang

    1988-06-01

    In accordance with testing data of removing radon and its daughters by ventilation from shrinkage and filling stopes of uranium mines, a law of removing radon by ventilation from the stopes is analyzed and summed. According to the decay law of radon and its daughters, an accumulation equation of potential alpha energy from radon daughters is presented with hyperbolic regression equation. the calculating formulae of ventilation flow are derived from the accumulation equation for eliminating radon daughters in inlet flow with or without contamination. It has been proved that the amount of ventilation air calcuated could meet the requirements of radiation safety rationally and economically

  18. A passive radon dosemeter suitable for workplaces

    International Nuclear Information System (INIS)

    Orlando, C.; Orlando, P.; Patrizii, L.; Tommasino, L.; Tonnarini, S.; Trevisi, R.; Viola, P.

    2002-01-01

    The results obtained in different international intercomparisons on passive radon monitors have been analysed with the aim of identifying a suitable radon monitoring device for workplaces. From this analysis, the passive radon device, first developed for personal dosimetry in mines by the National Radiation Protection Board, UK (NRPB), has shown the most suitable set of characteristics. This radon monitor consists of a diffusion chamber, made of conductive plastic with less than 2 cm height, containing a CR-39 film (Columbia Resin 1939), as track detector. Radon detectors in workplaces may be exposed only during the working hours, thus requiring the storage of the detectors in low-radon zones when not exposed. This paper describes how this problem can be solved. Since track detectors are also efficient neutron dosemeters, care should be taken when radon monitors are used in workplaces, where they may be exposed to neutrons, such as on high altitude mountains, in the surroundings of high energy X ray facilities (where neutrons are produced by (gamma, n) reactions) or around high energy particle accelerators. To this end, the response of these passive radon monitors to high energy neutron fields has been investigated. (author)

  19. Final survey reports on radon concentration in Japan

    International Nuclear Information System (INIS)

    1997-03-01

    In order to grasp the present state of indoor radon concentration all over Japan, this survey was conducted in five years from Heisei 4 FY to 8 FY. Measurements were conducted using a radon and thoron separation apparatus so as to enable to develop radon and thoron separately. This was only one survey all over Japan obtained the only radon concentration by removing thoron perfectly. However, it was planned to obtain the mean indoor radon concentration all over Japan by limiting 20 houses for measurement aim because of limitation on numbers of the apparatus. In this survey, no extremely high region of the radon concentration was found. However, it was comparatively higher in Chugoku, Kinki and Kyushu-Okinawa areas, but was comparatively low in Kanto area. These results showed the same tendency as those of γ-ray level from the ground, and the radon concentration also showed temperature difference of a tendency of higher west and lower east. In this survey, seasonal variation of the radon concentration was found. In the third quarter (from October to December) maximum radon concentration (mean value: 15 Bq/cu m) and in the second quarter, the minimum concentration (mean value: 9 Bq/cu m) were observed, respectively. On comparing the indoor radon concentration of each housing structure used in enquete survey, concrete block house showed higher radon concentration. On its arithmetic mean, the radon concentration was high in order of concrete, steel frame, and wood constructions, and lowest in prefabricated house. The radon concentration of the concrete construction showed about 1.8 times higher than that of the wood construction. (G.K.)

  20. Methodology developed to make the Quebec indoor radon potential map

    International Nuclear Information System (INIS)

    Drolet, Jean-Philippe; Martel, Richard; Poulin, Patrick; Dessau, Jean-Claude

    2014-01-01

    This paper presents a relevant approach to predict the indoor radon potential based on the combination of the radiogeochemical data and the indoor radon measurements in the Quebec province territory (Canada). The Quebec ministry of health asked for such a map to identify the radon-prone areas to manage the risk for the population related to indoor radon exposure. Three radiogeochemical criteria including (1) equivalent uranium (eU) concentration from airborne surface gamma-ray surveys, (2) uranium concentration measurements in sediments, (3) bedrock and surficial geology were combined with 3082 basement radon concentration measurements to identify the radon-prone areas. It was shown that it is possible to determine thresholds for the three criteria that implied statistically significant different levels of radon potential using Kruskal–Wallis one way analyses of variance by ranks. The three discretized radiogeochemical datasets were combined into a total predicted radon potential that sampled 98% of the studied area. The combination process was also based on Kruskal–Wallis one way ANOVA. Four statistically significant different predicted radon potential levels were created: low, medium, high and very high. Respectively 10 and 13% of the dwellings exceed the Canadian radon guideline of 200 Bq/m 3 in low and medium predicted radon potentials. These proportions rise up to 22 and 45% respectively for high and very high predicted radon potentials. This predictive map of indoor radon potential based on the radiogeochemical data was validated using a map of confirmed radon exposure in homes based on the basement radon measurements. It was shown that the map of predicted radon potential based on the radiogeochemical data was reliable to identify radon-prone areas even in zones where no indoor radon measurement exists. - Highlights: • 5 radiogeochemical datasets were used to map the geogenic indoor radon potential. • An indoor radon potential was determined for each

  1. The Norwegian information campaign on radon

    International Nuclear Information System (INIS)

    Thommesen, G.; Strand, T.

    1999-01-01

    The responsibility for providing an overview of 'all factors in the environment which are or may be having a direct or indirect influence on the health - -' rests with the municipal health authorities. In order to enable the municipal staff throughout Norway to accomplish local radon surveys, an information campaign on radon, including printed information material and training courses, was carried out in 1998-99, primarily directed towards municipal civil servants. The two-day training courses comprised of lectures and a compendium covering basic knowledge on ionizing radiation, sources of radon, measurement techniques, health risk, prophylactic and remedial measures, design and accomplishment of survey projects, and information strategy. The printed information material includes booklets providing general information on radon (health risks, measurements, and mitigation), methods for measuring radon in indoor air and construction sites, action levels, and design of municipal radon surveys. Two posters have been issued, one mainly intended for public offices and waiting rooms to motivate the public for radon measurements, the other one intended for municipal personnel and governmental offices, the latter also issued as a collection of fact sheets intended for schools etc. the booklets are displayed on the Internet (www.nrpa.no). The site also contains links to further information on mitigation techniques and economic support to remedial measures. (au)

  2. Indoor radon survey in Eastern Sicily

    International Nuclear Information System (INIS)

    Catalano, R.; Immè, G.; Mangano, G.; Morelli, D.; Tazzer, A. Rosselli

    2012-01-01

    Inhalation of radon (Rn-222) and its progeny is one of the most significant sources of natural radiation exposure of the population. Nowadays, high radon exposures have been shown to cause lung cancer and many governments all over the world have therefore recommended that radon exposures in dwellings and indoor workplaces should be limited. Radon levels in buildings vary widely from area to area depending on local geology. This paper presents the results of a long-term survey of radon concentrations carried out from 2005 till 2010 in schools and dwellings of Eastern Sicily, using the solid-state nuclear track detector (SSNTD) technique. The investigated area shows medium-high indoor radon concentrations, higher than the Italian average of about 70 Bq/m 3 , with peaks of 500 Bq/m 3 or more in buildings near active faults. Fortunately, only a small fraction of the measurements, about 1.5% of total, was found greater than EU and Italian action limits for indoor and workplaces. - Highlights: ► In this paper we report radon monitoring survey carried out in the east Sicily in schools and dwellings. ► The detection methodology was the solid-state nuclear track detector one. ► The work was supported by a national projects financed by the National Institute of Nuclear Physics.

  3. Efecto del aceite esencial de Cymbopogon citratus sobre propiedades fisicoquímicas en películas de quitosano

    Directory of Open Access Journals (Sweden)

    María del Carmen Vázquez - Briones

    2017-01-01

    Full Text Available Se investigó el efecto de la incorporación de aceite esencial de zacate limón ( Cymbopogon citratus , en concentraciones de 0, 200 y 400 ppm, en las propiedades fisicoquímicas (espesor, humedad, solubilidad, permeabilidad al vapor de agua, color, transparencia y mecánicas (resistencia a la tensión y elongación de películas de quitosano a dos concentraciones (1 y 3%. Los resultados mostraron un efecto significativo (p ≤ 0,05 en los valores del espesor de las películas a las dos concentraciones de quitosano. Se observó un efecto significativo (p ≤ 0,05 en los valores de humedad a concentraciones de 0, 200 y 400 ppm de aceite esencial. La adición de aceite esencial en películas de quitosano mostró un efecto significativo (p ≤ 0,05 en los valores de permeabili dad al vapor de agua. La concentración de quitosano mostró un efecto significativo (p ≤ 0,05 en transparencia y en los parámetros de color L* , a* , b* . Al variar la concentración de quitosano se observó un incremento significativo (p ≤ 0,05 en los valores de resistencia a la tensión de las películas de quitosano.

  4. Radon in the workplace

    International Nuclear Information System (INIS)

    Scivyer, C.R.; Gregory, T.J.

    1995-01-01

    This Guide has been prepared for the Health and Safety Executive (HSE) by the Building Research Establishment (BRE). Following the guidance is not compulsory and you are free to take other action. However if you do follow the guidance you will normally be doing enough to comply with the law. Health and Safety Inspectors seek to secure compliance with the law and may refer to this guidance as illustrating good practice. In the past, concern about exposure of employees to radon has largely centred on the mining environment. In recent times, with increased knowledge and mapping of radon levels in homes, attention has increasingly turned to radon exposure in buildings used for work purposes. Now there is a considerable fund of information to show that employees in some buildings can receive very significant radiation doses from radon. Surveys show that levels of radon tend to be higher in buildings with small rooms, such as offices rather than larger factory and warehouse constructions. The particular problem is that the nature of the work process gives no clue as to the radon hazard that may exist, and the employer may be unaware of its presence and how to deal with it. This Guide is aimed principally at employers and those who control buildings used for work purposes, or their representatives. It offers guidance on practical measures for reducing radon levels in workplaces. The guidance should also be of interest and assistance to those, such as surveyors and builders, concerned with specifying and carrying out the necessary remedial measures. Advice is provided for the majority of building types and construction situations likely to be encountered in larger non-domestic buildings. For buildings where construction is similar to that found in dwellings the guidance published by BRE on remedial measures for dwellings should be used. BRE prepared this Guide with assistance from the National Radiological Protection Board (NRPB) and Cornwall County Council under contract

  5. Development of a small-sized radon data logger

    International Nuclear Information System (INIS)

    Tasaka, Shigeki; Sasaki, Yoshimi

    1996-01-01

    A small-sized radon data logger and a electrostatic collecting radon monitor were developed for the continuous monitoring of environmental radon and radon daughters. A PIN photodiode (PD), an alpha particle defector, installed inside a container attracts radon daughters when charged electrostatically. Alpha particles are completely separated from each other according to the energy level. New logger has made it possible 10 analysts and save the radon data. Alpha particle count data from radon daughters are automatically integrated over preset time intervals and the energy regions. The desiccant P 2 O 5 was placed in the bottom of the monitor, since the collection efficiency of 218 Po atoms depends on the humidity of the air. We can get the 30 days continuous data logging at 30 min sampling frequency at any place with the car battery. We observed the radon concentration of the air inside the Super-Kamiokande dome from Jan-30 to Feb-8-1996. The average of radon concentration was found to be (46±13) Bq/m 3 . (author)

  6. Indoor radon levels in coastal Karnataka

    International Nuclear Information System (INIS)

    Narayana, Y.; Radhakrishna, A.P.; Somashekarappa, H.M.; Karunakara, N.; Balakrishna, K.M.; Siddappa, K.

    1995-01-01

    Indoor radon levels have been measured in selected dwellings of coastal Karnataka using LR-115 type II peelable films and it is found to vary from 28.4 to 45.6 Bq m -3 with a geometric mean value of 35.7 Bq m -3 . The annual effective dose equivalent to the population of the region due to inhalation of radon was estimated from the measured data on radon level and is found to be in the range 1.9 - 3.1 mSv y -1 with a mean value 2.4 mSv y -1 . The correlation between indoor radon level and radium content in the underlying soil were studied. No definite correlation was observed to exist between indoor radon level and radium content in soil. (author). 24 refs., 2 tabs

  7. Measurements of radon concentrations in dwelling houses

    International Nuclear Information System (INIS)

    Birkholz, W.; Klink, T.

    1993-01-01

    Radon and its daughter products gain in importance in health protection and radiation safety. Especially in the southern region of Saxony radon concentrations in dwellings may be high by former silver and uranium mines. We found radon contents of about 20.000 Bq/m 3 in dwellings. To redevelop such houses it is necessary to know intrude path of radon. In present work we studied different measuring systems, active and passive detectors, short and long term integrating devices. By means of investigation of radon sources several redeveloping methods are rates as well from radiological as from civil engineering point of view. (author)

  8. Communicating the risk from radon

    International Nuclear Information System (INIS)

    Fisher, A.; McClelland, G.H.; Schulze, W.D.; Doyle, J.K.

    1991-01-01

    A prominent television station developed a special series of newscasts and public service announcements about radon. This was combined with their advertising of the availability of reduced-price radon test kits in a local supermarket chain. The large number of test kits sold was a success from a marketing perspective, but not from a public health perspective - especially because of the very small share of high readings that were mitigated. In contrast, a study of housing sales showed a much higher testing rate and corresponding mitigation when risk communication accompanied the housing transaction, rather than being directed toward the general public. This paper examined the relative effectiveness of these alternative approaches to radon risk communication, emphasizing the implications for developing and implementing radon programs

  9. Radon in dwellings and shelters in Zagreb

    International Nuclear Information System (INIS)

    Lokobauer, N.; Franic, Z.; Sencar, J.; Bauman, A.

    1994-01-01

    Since 1990, radon activity was measured in dwellings of Zagreb. In only small number of dwellings radon activity exceeded 100 Bq.m -3 . Since the inhabitants of Croatia have to stay in the facilities below the ground due to the war against Croatia, the paper gives also data on radon activity measured in the shelters and cellars in 1991. Measurements were performed using Kodak LR-115 detectors, type II. At several locations radon activity was measured with a silicon detector (Radhome). Radon values obtained for the shelters, cellars and dwellings at all locations were compared. With respect to children as most susceptable population group the paper gives data on radon activity for kindergartens and elementary schools (and its shelters) where children usually spend almost one-third to the day. (orig.)

  10. High indoor radon concentrations in some Swedish waterworks

    International Nuclear Information System (INIS)

    Aakerblom, G.; Hagberg, N.; Mjoenes, L.; Heiberg, A.

    2002-01-01

    High indoor radon concentrations in buildings used for water treatment are not uncommon. When raw water is processed in an open system radon escapes from the water to the indoor air of the premises. It is not unusual that the staff of the waterworks have their offices in the building where the water is processed. If large volumes of water are processed and the evaporated radon can reach the workplaces the indoor radon concentration can be very high even if the radon concentration of the raw water is moderate. Groundwaters from aquifers in bedrock and soil and surface water that has been infiltrated through deposits of sand or gravel have the potential to cause high indoor radon levels. In surface water emanating directly from a lake or a river the radon concentrations are normally too low to cause problems. Three waterworks in central Sweden have been studied, Ludvika, Fredriksberg and Kolbaeck. The radon concentrations in the raw water of these waterworks are from 85 Bq/l to 300 Bq/l. Average indoor radon concentrations exceeding 17,000 Bq/m 3 have been measured in Ludvika with peaks of almost 37,000 Bq/m 3 . In Kolbaeck radon concentrations up to 56,000 Bq/m 3 have been measured. It is quite possible that employees of waterworks can receive doses exceeding 20 mSv per year (calculated according to ICRP:s dose conversion convention). Measurements of radon and gamma radiation from the waterworks are reported and methods to lower the indoor radon concentrations are discussed. (author)

  11. Estudio bioquímico del veneno de la serpiente Bothrops hyoprorus

    Directory of Open Access Journals (Sweden)

    César Bonilla

    1997-07-01

    Full Text Available Se describe la purificación parcial de la enzima Fosfolipasa A del veneno de Bothrops hyoprorus y la caracterización de sus actividades hemolítica y citotóxica. La actividad fosfolipásica se detectó en dos fracciones de 23 y 12 Kd por cromatografía en Sephadex G-100 y G-50. Las actividades fosfolipásica y hemolítica fueron detectadas en las mismas fracciones. Los ensayos de Western-blot, sugieren que la fracción con 12 Kd es un producto de degradación, in-vitro, del polipéptido mayor. La actividad citotóxica de la fracción fue evidente sólo a elevadas concentraciones, sugiriéndose que moléculas diferentes a Fosfolipasa A serián responsables del efecto citotóxico del veneno

  12. Measuring radon in the workplace

    International Nuclear Information System (INIS)

    Boyd, M.

    1990-01-01

    The Environmental Protection Agency (EPA) has issued guidance for testing for radon in homes and interim guidance for testing in schools. Information on testing for radon in the workplace is the next initiative and this paper describes the current status of this effort. The results of measurements made in several buildings in the Washington, DC area are discussed. In this paper a discussion of preliminary guidance on radon survey design that has been offered to Federal agencies is presented

  13. Proceedings of radon and radon progeny measurements in Australia symposium

    International Nuclear Information System (INIS)

    Akber, R.A.; Harris, F.

    1994-01-01

    This publication contain papers presented at a symposium on radon and radon progeny measurements in Australia, held in Canberra on 18 February 1994. The emphasis was on results of measurements in different exposure situations, however information on methodology and techniques was also included. The scope of the symposium expanded through participation by scientists from China, French Polynesia and New Zealand. A list of participants and their organizations is included at the end of the proceedings. refs., tabs., figs

  14. Project radon final report

    International Nuclear Information System (INIS)

    Ekholm, S.; Rossby, U.

    1990-01-01

    The main radiation problem in Sweden is due to radon in dwellings. At the Swedish State Power Board, R, D and D about radon has been going on since 1980. The work has concentrated on the important questions: How to find building with enhanced radon levels?; How to accurately decide on measures that will give adequate cleaning-up results, using appropriate measurement procedures; What cleaning-up effect is possible to achieve with an electro-filter?; and What cleaning-up effects are possible to achieve with different types of ventilation systems? The R, D and D-work, has been pursued in cooperation with universities of technology in Denmark and Finland, equipment manufacturers, consultants and authorities concerned. It was decided in December 1986 to give an offer to some SSPB-employees to investigate the radon situation of their dwellings, in order to test methods of measurement and cleaning-up under realistic conditions and to develop the methods to commercial maturity. The investigation was named 'Project Radon' and was carried out in three years with costs amounting to 1 M dollars. During the project less comprehensive radon measurements, named 'trace-measurements' were undertaken in about 1300 dwellings and more elaborate measurements, leading to suggestions of actions to be taken, in about 400 dwellings. Out of the suggestions, about 50 are carried out including control measurement after actions taken. The control measurement have shown that the ability to suggest appropriate actions is very successful - in just one case was a minor additional action necessary. The high reliability is achieved by always doing elaborate measurements before suggested mitigation method is decided on. (authors)

  15. Effect of fresh air ventilation on indoor radon concentration

    International Nuclear Information System (INIS)

    Sun Hao; Wu Jianhua; Fu Shi

    2012-01-01

    The radon concentration of laboratory for radon simulation (LRS) was measured by the RAD7 radon monitor, and the effect of the different fresh air ventilations on indoor radon concentration was studied and analyzed. The indoor radon concentration of LRS can be accumulated up to 2000 Bq/m 3 and the average radon exhalation rate of the LRS is 14.5 Bq · m -2 . h -1 . Furthermore, when the fresh air enters into the LRS continuously, the indoor radon concentration decreases exponentially with the increase of time. The equilibrium radon concentration and equilibrium time of LRS decrease exponentially with the increase of the rate of fresh air ventilation. In addition, the indoor radon concentration increases by accumulation with the decrease of the rate of fresh air ventilation. (authors)

  16. A radon progeny deposition model

    International Nuclear Information System (INIS)

    Rielage, Keith; Elliott, Steven R.; Hime, Andrew; Guiseppe, Vincent E.; Westerdale, S.

    2010-01-01

    The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly 222 Rn) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of 210 Pb on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.

  17. A Radon Progeny Deposition Model

    International Nuclear Information System (INIS)

    Guiseppe, V. E.; Elliott, S. R.; Hime, A.; Rielage, K.; Westerdale, S.

    2011-01-01

    The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly 222 Rn) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of 210 Pb on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.

  18. Radon in buildings: instrumentation of an experimental house

    International Nuclear Information System (INIS)

    Ameon, R.; Diez, O.; Dupuis, M.; Merle-Szeremeta, A.

    2004-01-01

    IRSN decided to develop a code called RADON 2 for conducting simple and methodical studies of indoor radon concentrations. Since a validity check must be performed of the phenomenological model on which the code is based, an experimental program was initiated in 2002, within which a house in Brittany, located on a well-characterized uranium-bearing geological formation, was fitted with special instruments. After characterizing the soil underlying the house, the instrumentation implemented on site continuously monitors a number of parameters to characterize: the radon source term in the building (exhalation rate of 222 Rn at the ground/building interface and at soil surface, radon concentration in the soil and in outdoor air); radon penetration by advection (differential pressure in the house basement); the driving mechanisms for natural ventilation in the house (weather conditions, indoor temperature and relative humidity); radon distribution throughout the house by air flow and radon diffusion (indoor radon concentration at each floor of the house). Using the experimental data acquired over the past two years, the phenomena governing radon penetration inside the house (wind and stack effect) and radon extraction (fresh air supply rate) have been characterized to lay down the bases for validating the newly developed code

  19. Determination of radon in soil and water in parts of Accra, and generation of preliminary radon map for Ghana

    International Nuclear Information System (INIS)

    Osei, Peter

    2016-07-01

    The research was focused on determining the radon levels in soil and water in parts of Accra, generate a preliminary radon map for Ghana and estimate a pilot reference level for the country, using the data obtained from this research and collated data from other researchers. The radon gas measurement was done with the passive method, using the SSNTDs which are sensitive to alpha particles emitted by radon. Cellulose nitrate LR – 115 type II alpha particle detectors were used. The detectors were chemically etched in a 2.5 M NaOH solution at a temperature of 60 °C for 90 minutes, after two weeks and two months of exposure to soil and water respectively. The images of the etched detectors were acquired by means of a scanner and then tracks counted with ImageJ software. Inverse Distance Weighing (IDW) method of ArcGIS 10.2 was used to spatially distribute the radon concentration on a map. The average soil radon concentration in the study area ranges from 0.191 kBqm"-"3 to 3.416 kBqm"-"3 with a mean of 1.193 kBqm"-"3. The radon concentration in water from the study area ranges from 0.00346 BqL"-"1 to 0.00538 BqL"-"1 with an average of 0.00456 BqL"-"1. A strong negative correlation has been established between radon in soil and water in the study area. The preliminary national average indoor, water and soil radon concentrations are 137 Bqm"-"3, 361.93 Bqm"-"3 and 3716.74 Bqm"-"3 respectively. The average levels of water and indoor radon exceeded WHO’s reference level of 100 Bqm"-"3. Accordingly, the pilot national indoor radon reference level for Ghana is set as 200 Bqm"-"3. (au)

  20. Observaciones histopatologicas de juveniles penaeus vannamei sometidos a dietas artificiales con diferentes concentraciones de una sal de ácido ascórbico (vitamina c)

    OpenAIRE

    Vera Muñoz, L.

    1995-01-01

    Observaciones histopatologicas de juveniles Penaeus Vannamei sometidos a dietas artificiales con diferentes concentraciones de una sal de ácido ascórbico (vitamina C) Se realizaron análisis histológicos y comprobación mediante métodos histoquímicos de la presencia de melanina, a juveniles Penaeus vannamei sometidos a cinco dietas experimentales con diferentes concentraciones de una sal de L-Ascorbato-2-Fosfato de Mg (APM) usada como fuente de ácido ascórbico (AA).

  1. Comparison of radon and radon-daughter grab samples obtained during the winter and summer

    International Nuclear Information System (INIS)

    Karp, K.E.

    1987-08-01

    The Technical Measurements Center (TMC), under the auspices of the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) program, is investigating short-term methods for estimating annual average indoor radon-daughter concentrations (RDC). A field study at 40 sample locations in 26 residential structures in Grand Junction, Colorado, was conducted once in the winter and once in the summer. The short-term methods investigated as part of this study include ten-minute radon and radon-daughter grab sampling and hourly RDC measurements. The results of the field study indicate that ten-minute radon grab samples from basement locations are reproducible over different seasons during controlled sampling conditions. Nonbasement radon and RDC grab samples are highly variable even when the use of the location by the occupant is controlled and the ventilation rate is restricted. The grab sampling was performed under controlled occupied conditions. These results confirm that a short-term radon or RDC measurement in a nonbasement location in a house is not a standardized measurement that can be used to infer an annual average concentration. The hourly RDC measurements were performed under three sets of conditions over a 72-hour period. The three sets of conditions were uncontrolled occupied, controlled occupied, and controlled unoccupied. These results indicate that it is not necessary to relocate the occupants during the time of grab sampling. 8 refs., 8 figs., 10 tabs

  2. Assessment of radiation exposure to miners due to radon and radon daughters

    International Nuclear Information System (INIS)

    Przyborowski, S.

    1979-01-01

    An overview is given of the basic considerations regarding the establishment of lung limits for miners exposed to radon and radon daughters. Problems associated with the practical conduct of radiation protection monitoring are also dealt with, for example, the implications of temporal and local variations in activity levels to the mode of sampling and the interpretation of results. (author)

  3. Indoor radon concentrations and radon doses at three districts of Ankara, Turkey and raising public awareness on the issue

    International Nuclear Information System (INIS)

    Mehmet Kildir; Inci Goekmen; Ali Goekmen

    2016-01-01

    Indoor radon concentrations at METU, CIGDEM and DOSTLAR in Ankara were measured using electrets. The statistical analysis of the data indicated a lognormal distribution of radon concentrations, with no significant difference between CIGDEM and DOSTLAR with geometric means of GM = 87.5 and 54.5 Bq m -3 , respectively. Radon concentrations did not change seasonally at CIGDEM which contain modern buildings, but at the slum district DOSTLAR, with poor insulation of houses a seasonal variation was observed. Annual effective radon doses were estimated (0.4-8.4 mSv). Public awareness about indoor radon was raised. (author)

  4. Canadian population risk of radon induced lung cancer variation range assessment based on various radon risk models

    International Nuclear Information System (INIS)

    Chen, Jing

    2017-01-01

    To address public concerns regarding radon risk and variations in risk estimates based on various risk models available in the literature, lifetime lung cancer risks were calculated with five well-known risk models using more recent Canadian vital statistics (5-year averages from 2008 to 2012). Variations in population risk estimation among various models were assessed. The results showed that the Canadian population risk of radon induced lung cancer can vary from 5.0 to 17% for men and 5.1 to 18% for women based on different radon risk models. Averaged over the estimates from various risk models with better radon dosimetry, 13% of lung cancer deaths among Canadian males and 14% of lung cancer deaths among Canadian females were attributable to long-term indoor radon exposure. (authors)

  5. Application of nuclear track detectors for radon related measurments

    International Nuclear Information System (INIS)

    Abu-Jarad, F.A.

    1988-01-01

    The application of nuclear track detectors for radon related measurements is discussed. The ''Can Technique'', used for measuring radon emanation from building materials, walls and soil; the ''Working Level Monitor'', used for measuring short period working levels of radon daughters in houses; and ''Passive Radon Dosimeters'', used to measure radon levels in houses for long term (few months) periods are described. Application of nuclear track detectors for measuring the radon daughters plate-out on the surface of mixing fan blades and walls are discussed. The uranium content of some wall papers was found to be 6 ppm. The variation of radon progeny concentration in the same room was measured and supported by another study through Gas Chromatograph measurements. The independence of radon concentration on room level in high-rise buildings was established. The effect of sub-floor radon emanation on radon concentration in houses is dependent on whether there is sub-floor ventilation or not. (author)

  6. Fluid-based radon mitigation technology development for industrial applications

    International Nuclear Information System (INIS)

    Liu, K.V.; Gabor, J.D.; Holtz, R.E.; Gross, K.C.

    1996-01-01

    The objective of the radon mitigation technology development effort is to develop an efficient and economical radon gas removal technology based on a fluid absorption process. The technology must be capable of cleaning up a wide range of radon gas stream concentrations to a level that meets EPA gas emission standards for residential and industrial applications. Argonne has recently identified a phenomenon that offers the possibility of radon recovery from the atmosphere with high efficiency at room temperature, and radon release at slightly elevated temperatures (50-60 degrees C.) such a device would offer numerous substantial advantages over conventional cryogenic charcoal systems for the removal of radon. Controlled sources of radon in Argonne's radon research facility are being used to quantitatively assess the performance of a selected class of absorbing fluids over a range of radon concentrations. This paper will discuss the design of laboratory- and engineering-scale radon absorption units and present some preliminary experimental test results

  7. The risks from radon in homes

    International Nuclear Information System (INIS)

    Duggan, M.J.

    1990-01-01

    A report has been proposed by a Working group of the Institute of Radiation Protection on the risks from radon in homes. The report includes a historical perspective, properties and behavior of radon and its daughters, measurement of radon exposure in UK homes, remedial action, quantification of the risk and lifetime risks from other causes. (UK)

  8. RADON AND CARCINOGENIC RISK IN MOSCOW

    Directory of Open Access Journals (Sweden)

    S. M. Golovanev

    2015-01-01

    Full Text Available Objective: comparative evaluation of carcinogenic risk inMoscowfrom radon in indoor and atmospheric pollutants.Materials and methods: the lung cancer incidence in Moscow; radiation-hygienic passport of the territory; .U.S. EPA estimated average age at all and radon induced deaths, years of life lost; Report of UNSCEAR 2006 and WHO handbook on indoor radon, 2009. Trend analysis of incidence; evaluation of the excess relative risk; assessment of ratio radon-induced population risk and published values оf total population carcinogenic risk from chemical carcinogens.Results: it is shown that the 304 cases of lung cancer per year (1. 85 10-3 on average from 2006 to 2011 (21280diseases for 70 years in addition to background level induced by radon; the differences in average trends of all lungcancer incidence in the districts can exceed 25%.Conclusion. The potential of risk reduction by measures of mitigation radon concentration exceeds 5 times the cost efficiency to reduce emissions from vehicles and can reduce cancer incidence, on average 236 cases per year; population risk 16520 cases over 70 years or save not less than 2832 person-years of life per year. The annual effect of reducing losses from not-survival of 12 years as a result of radon-induced lung cancer deaths exceeds 14160000 dollars. The evaluating of the carcinogenic risk from radon in accordance with the definition of population risk increases the predictive evaluation of the effectiveness of preventive measures more than twice.

  9. Concentration variation of radon in the room

    International Nuclear Information System (INIS)

    Komaruzaman Mohd Noor; Haziman Hassan; Rosli Mahat; Yusof Md Amin

    1995-01-01

    The study was carried out to determine the variation of radon concentration in the room. Radon detector used was solid nuclear tracks detector (SSNTD) LR-115. From this result, suitable points to make radon measurement was determined

  10. Environmental Radon Gas and Degenerative Conditions An Overview

    International Nuclear Information System (INIS)

    Groves-Kirkby, C.J.; Denman, A.R.; Woolridge, A.C.; Phillips, P.S.; Phillips, C.

    2006-01-01

    Radon, a naturally occurring radioactive gas, has variable distribution in the environment as a decay product of uranium occurring in a wide range of rocks, soils and building materials. Although radon dissipates rapidly in outdoor air, it concentrates in the built environment, and inhalation of 222 Rn and its progeny 218 Po and 214 Po is believed to provide the majority of the radioactive dose to the respiratory system. While the connection between radon and lung cancer has long been recognised and investigated, recent studies have highlighted potential links between radon and other conditions, among them Multiple Sclerosis, Alzheimer and Parkinson Diseases, and Paget Disease of Bone. A strong case exists for clarifying the relationship between radon and these other conditions, not least since radon remediation to reduce lung cancer may conceivably have additional benefits hitherto unrecognized. The present status of the postulated links between environmental radon gas and degenerative conditions is reviewed, and recommendations for further research into levering current anti-radon campaigns are made. (authors)

  11. Radon removal from gaseous xenon with activated charcoal

    Energy Technology Data Exchange (ETDEWEB)

    Abe, K.; Hieda, K.; Hiraide, K.; Hirano, S.; Kishimoto, Y.; Kobayashi, K.; Koshio, Y. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Liu, J.; Martens, K. [Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Moriyama, S. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Nakahata, M. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Nishiie, H.; Ogawa, H.; Sekiya, H.; Shinozaki, A. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Suzuki, Y. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Takachio, O.; Takeda, A.; Ueshima, K.; Umemoto, D. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); and others

    2012-01-01

    Many low background experiments using xenon need to remove radioactive radon to improve their sensitivities. However, no method of continually removing radon from xenon has been described in the literature. We studied a method to remove radon from xenon gas through an activated charcoal trap. From our measurements we infer a linear relationship between the mean propagation velocity v{sub Rn} of radon and v{sub Xe} of xenon in the trap with v{sub Rn}/v{sub Xe}=(0.96{+-}0.10) Multiplication-Sign 10{sup -3} at -85 Degree-Sign C. As the mechanism for radon removal in this charcoal trap is its decay, knowledge of this parameter allows us to design an efficient radon removal system for the XMASS experiment. The verification of this system found that it reduces radon by a factor of 0.07, which is in line with its expected average retention time of 14.8 days for radon.

  12. Intercomparison 2003 for Radon measurement services at PSI

    CERN Document Server

    Butterweck, G

    2003-01-01

    Twelve radon measurement services participated in the 2003 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut (PSI) during March 13th to 24th, 2003. Ten of these laboratories were approved by the Swiss Federal Office of Public Health and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas detectors (etched-track and electret ionisation chambers) and instruments (ionisation chambers and electrostatic precipitation) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 1950 Bqm sup - sup 3 leading to a radon gas exposure of 517 kBqhm sup - sup 3. Additional five electret-detectors of an approved measuring service were purchased by the Swiss Federal Office of Public Health for a spot check. Two of these were exposed as described above, two had an exposure of 247 kBqhm sup - sup 3 at an average radon concen...

  13. Methodology developed to make the Quebec indoor radon potential map

    Energy Technology Data Exchange (ETDEWEB)

    Drolet, Jean-Philippe, E-mail: jean-philippe.drolet@ete.inrs.ca [Institut national de la recherche scientifique, Eau Terre Environnement Research Centre (ETE-INRS), 490 de la Couronne, G1K 9A9 Quebec (Canada); Martel, Richard [Institut national de la recherche scientifique, Eau Terre Environnement Research Centre (ETE-INRS), 490 de la Couronne, G1K 9A9 Quebec (Canada); Poulin, Patrick [Institut national de santé publique du Québec (INSPQ), 945 avenue Wolfe, G1V 5B3 Quebec (Canada); Dessau, Jean-Claude [Agence de la santé et des services sociaux des Laurentides, 1000 rue Labelle, J7Z 5 N6 Saint-Jérome (Canada)

    2014-03-01

    This paper presents a relevant approach to predict the indoor radon potential based on the combination of the radiogeochemical data and the indoor radon measurements in the Quebec province territory (Canada). The Quebec ministry of health asked for such a map to identify the radon-prone areas to manage the risk for the population related to indoor radon exposure. Three radiogeochemical criteria including (1) equivalent uranium (eU) concentration from airborne surface gamma-ray surveys, (2) uranium concentration measurements in sediments, (3) bedrock and surficial geology were combined with 3082 basement radon concentration measurements to identify the radon-prone areas. It was shown that it is possible to determine thresholds for the three criteria that implied statistically significant different levels of radon potential using Kruskal–Wallis one way analyses of variance by ranks. The three discretized radiogeochemical datasets were combined into a total predicted radon potential that sampled 98% of the studied area. The combination process was also based on Kruskal–Wallis one way ANOVA. Four statistically significant different predicted radon potential levels were created: low, medium, high and very high. Respectively 10 and 13% of the dwellings exceed the Canadian radon guideline of 200 Bq/m{sup 3} in low and medium predicted radon potentials. These proportions rise up to 22 and 45% respectively for high and very high predicted radon potentials. This predictive map of indoor radon potential based on the radiogeochemical data was validated using a map of confirmed radon exposure in homes based on the basement radon measurements. It was shown that the map of predicted radon potential based on the radiogeochemical data was reliable to identify radon-prone areas even in zones where no indoor radon measurement exists. - Highlights: • 5 radiogeochemical datasets were used to map the geogenic indoor radon potential. • An indoor radon potential was determined for

  14. [The methods of assessment of health risk from exposure to radon and radon daughters].

    Science.gov (United States)

    Demin, V F; Zhukovskiy, M V; Kiselev, S M

    2014-01-01

    The critical analysis of existing models of the relationship dose-effect (RDE) for radon exposure on human health has been performed. Conclusion about the necessity and possibility of improving these models has been made. A new improved version ofthe RDE has been developed. A technique for assessing the human health risk of exposure to radon, including the method for estimating of exposure doses of radon, an improved model of RDE, proper methodology risk assessment has been described. Methodology is proposed for the use in the territory of Russia.

  15. Physics underlying the searching for radon sources in houses

    International Nuclear Information System (INIS)

    Thomas, J.

    1992-01-01

    The radon diagnostics of houses is briefly outlined. The aim of radon diagnostics consists in the identification of radon sources (subsoil, building material, water), location of the main and side pathways of radon inlet in the building, quantification of the amounts of radon passing through the pathways and spreading through the house. The stack effect of radon suction from the subsoil into the building due to the temperature difference or underpressure caused by wind is described. The radon risk is different in the different seasons of the year and also varies throughout the day. Good diagnosis of radon transfer into a house requires a great deal of skill. (M.D.). 1 fig

  16. Low-Cost Radon Reduction Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Rose, William B. [Partnership for Advanced Residential Retrofit, Champaign, IL (United States); Francisco, Paul W. [Partnership for Advanced Residential Retrofit, Champaign, IL (United States); Merrin, Zachary [Partnership for Advanced Residential Retrofit, Champaign, IL (United States)

    2015-09-01

    The aim of the research was to conduct a primary scoping study on the impact of air sealing between the foundation and the living space on radon transport reduction across the foundation-living space floor assembly. Fifteen homes in the Champaign, Illinois area participated in the study. These homes were instrumented for hourly continuous radon measurements and simultaneous temperature and humidity the foundation was improved. However, this improved isolation did not lead to significant reductions in radon concentration in the living space. Other factors such as outdoor temperature were shown to have an impact on radon concentration.

  17. Establishment of a radon test chamber

    International Nuclear Information System (INIS)

    Chen Chingjiang; Liu Chichang; Lin Yuming

    1993-01-01

    A walk-in type radon test chamber of 23 m 3 has been built for testing and calibration of radon measurement instruments. The environmental conditions of the test chamber can be varied within a wide range of values. The design objectives specification, monitoring instruments and testing results of this chamber are discussed. This test chamber is available for domestic radon researchers and its accuracy can be traced to the international standard. A routine intercomparison study will be held annually by using this chamber. Other tests like radon progeny and thoron standard may also be performed in this chamber. (1 fig.)

  18. Modeled atmospheric radon concentrations from uranium mines

    Energy Technology Data Exchange (ETDEWEB)

    Droppo, J.G.

    1985-04-01

    Uranium mining and milling operations result in the release of radon from numerous sources of various types and strengths. The US Environmental Protection Agency (EPA) under the Clean Air Act, is assessing the health impact of air emissions of radon from underground uranium mines. In this case, the radon emissions may impact workers and residents in the mine vicinity. To aid in this assessment, the EPA needs to know how mine releases can affect the radon concentrations at populated locations. To obtain this type of information, Pacific Northwest Laboratory used the radon emissions, release characteristics and local meterological conditions for a number of mines to model incremental radon concentrations. Long-term, average, incremental radon concentrations were computed based on the best available information on release rates, plume rise parameters, number and locations of vents, and local dispersion climatology. Calculations are made for a model mine, individual mines, and multiple mines. Our approach was to start with a general case and then consider specific cases for comparison. A model underground uranium mine was used to provide definition of the order of magnitude of typical impacts. Then computations were made for specific mines using the best mine-specific information available for each mine. These case study results are expressed as predicted incremental radon concentration contours plotted on maps with local population data from a previous study. Finally, the effect of possible overlap of radon releases from nearby mines was studied by calculating cumulative radon concentrations for multiple mines in a region with many mines. The dispersion model, modeling assumptions, data sources, computational procedures, and results are documented in this report. 7 refs., 27 figs., 18 tabs.

  19. Modeled atmospheric radon concentrations from uranium mines

    International Nuclear Information System (INIS)

    Droppo, J.G.

    1985-04-01

    Uranium mining and milling operations result in the release of radon from numerous sources of various types and strengths. The US Environmental Protection Agency (EPA) under the Clean Air Act, is assessing the health impact of air emissions of radon from underground uranium mines. In this case, the radon emissions may impact workers and residents in the mine vicinity. To aid in this assessment, the EPA needs to know how mine releases can affect the radon concentrations at populated locations. To obtain this type of information, Pacific Northwest Laboratory used the radon emissions, release characteristics and local meterological conditions for a number of mines to model incremental radon concentrations. Long-term, average, incremental radon concentrations were computed based on the best available information on release rates, plume rise parameters, number and locations of vents, and local dispersion climatology. Calculations are made for a model mine, individual mines, and multiple mines. Our approach was to start with a general case and then consider specific cases for comparison. A model underground uranium mine was used to provide definition of the order of magnitude of typical impacts. Then computations were made for specific mines using the best mine-specific information available for each mine. These case study results are expressed as predicted incremental radon concentration contours plotted on maps with local population data from a previous study. Finally, the effect of possible overlap of radon releases from nearby mines was studied by calculating cumulative radon concentrations for multiple mines in a region with many mines. The dispersion model, modeling assumptions, data sources, computational procedures, and results are documented in this report. 7 refs., 27 figs., 18 tabs

  20. Controlling exposure to radon, France, December 2006

    International Nuclear Information System (INIS)

    Godet, J.L.; Perrin, M.L.; Dechaux, E.; Pineau, C.

    2007-01-01

    Controlling exposure to radon, France, December 2006 Exposure to radon, along with medical exposure, is the leading source of the French population exposure to ionizing radiation. Radon is a confirmed cause of lung cancer in man (classified in group I by the international Agency for research on Cancer (I.A.R.C.)). According to available estimates, the numbers of lung cancers attributable to radon exposure in France are far fewer than those caused by tobacco. However, according to a recent European study, around 9% of lung cancers in Europe may be caused by radon. Thus, due to the number of people exposed, radon has become a public health issue which calls for action, considering that exposure can be significantly reduced by implementing measures which are often simple. Since 2002, the Nuclear Safety Authority (Asn) has proceeded in implementing a new regulatory framework for the risk management related to the presence of radon in public places. The new system is now fully operational. In addition, based on the initiatives adopted by the government in June 2004 in the context of the National Health and Environment Plan (P.N.S.E.), the Asn drew up a plan in 2005, in collaboration with the Ministry for Urban Planning and Construction, to coordinate the actions of various national bodies involved in this field. This three-pronged strategy is as follows: - Creation of a new risk management policy related to the presence of radon in existing homes and in new buildings; - Supporting and controlling the implementation of regulations for managing radon related risks in public places; - Improvement and dissemination of knowledge on radon exposure and its related risks. (author)

  1. Assessment of indoor radon gas concentration change of college

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hoon Hee; Jeong, Eui Hwan; Kim, Hak Jae; Lyu, Kang Yeul [Dept. of of Radiological Technology, Shingu College, Seongnam (Korea, Republic of); Lee, Ju Young [Dept. of Radiological Technology, Songho College, Hoengseong (Korea, Republic of)

    2017-03-15

    The purpose of this study was to assess the impact by comparing the concentration of indoor radon and look for ways to lower the concentration of indoor radon gas measurements of three variables, the year of completion, volume of the building and ventilation. Measurement target is six classrooms on the sixth floor of building that was constructed in 1973 and was extended in 2011. Selected classroom's volume is different. Four classrooms were selected to compare the radon concentration in accordance with the year of completion, Classrooms that is same year of completion were selected to compare the radon concentration in accordance with the volume, six classroom was performed closure and ventilation to compare radon concentration according to ventilation. Radon concentrations in accordance with the year of building completion showed a high concentration of radon in a building recently built. Also, Radon concentration in volume is high the smaller the volume. Radon concentration change according to ventilation showed a reduction of about 80% when the ventilation than during closing. Especially, The radon concentrations were high detected while the recently year of building completion and the smaller volume. Ventilation of the three variables is considered that can be expected to exposure reduction effect by radon affecting the greatest radon concentration reduction.

  2. Assessment of indoor radon gas concentration change of college

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Jeong, Eui Hwan; Kim, Hak Jae; Lyu, Kang Yeul; Lee, Ju Young

    2017-01-01

    The purpose of this study was to assess the impact by comparing the concentration of indoor radon and look for ways to lower the concentration of indoor radon gas measurements of three variables, the year of completion, volume of the building and ventilation. Measurement target is six classrooms on the sixth floor of building that was constructed in 1973 and was extended in 2011. Selected classroom's volume is different. Four classrooms were selected to compare the radon concentration in accordance with the year of completion, Classrooms that is same year of completion were selected to compare the radon concentration in accordance with the volume, six classroom was performed closure and ventilation to compare radon concentration according to ventilation. Radon concentrations in accordance with the year of building completion showed a high concentration of radon in a building recently built. Also, Radon concentration in volume is high the smaller the volume. Radon concentration change according to ventilation showed a reduction of about 80% when the ventilation than during closing. Especially, The radon concentrations were high detected while the recently year of building completion and the smaller volume. Ventilation of the three variables is considered that can be expected to exposure reduction effect by radon affecting the greatest radon concentration reduction

  3. Radon in schools. Report for May 1988-September 1989

    International Nuclear Information System (INIS)

    Leovic, K.W.

    1989-01-01

    The paper discusses radon entry into schools, radon mitigation approaches for schools, and school characteristics (e.g., HVAC system design and operation) that influence radon entry and mitigation system design. It also discusses mitigation systems installed by the U.S. EPA in four schools. The primary source of radon entry into a school with significantly elevated radon levels is normally soil gas that is drawn in by pressure differentials between the soil surrounding the substructure and the building interior. If the building interior is at a lower pressure than the soil surrounding the substructure and radon is present in the soil, the radon can be pulled in through cracks and other openings that are in contact with the soil. The amount of radon in a given classroom depends on the level of radon in the underlying material, the ease with which the radon moves as a component of the soil gas through the soil, the magnitude and direction of the pressure differentials, the number and size of the radon entry routes, and dilution and mixing of the room air. HVAC systems in schools vary considerably and tend to have greater impact on pressure differentials--and consequently radon levels--than do heating and air-conditioning (HAC) systems in houses

  4. Reduction of radon from household water supplies

    International Nuclear Information System (INIS)

    Shapiro, P.S.; Sorg, T.J.

    1988-01-01

    Groundwater can be a major source of indoor radon in homes that use individual wells or are served by very small community water supply systems. In the United States, several wells have been found to contain more than 37,000,000 Bq.m -3 of radon dissolved in the water. This radon can be released in the indoor air in the course of using water for normal household activities. A measurement of the radon in the drinking water can be made when an indoor radon problem is suspected. While ventilation may reduce indoor radon levels that result from household water usage, the most common control technique presently applied is removing the radon from the water using a granular activated carbon (GAC) treatment system. Aeration methods are also effective and have been proven to be economical for small community water supplies. Some of the issues faced in using GAC are sizing and maintaining the unit and shielding and disposing of the GAC to prevent exposure from gamma radiation. (author)

  5. Radon: a bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Lepman, S.R.; Boegel, M.L.; Hollowell, C.D.

    1981-01-01

    The Lawrence Berkeley Laboratory, with the support of the Department of Energy, has developed a computerized database to manage research information in the area of building ventilation and indoor air quality. This literature survey contains references pertaining to the physical properties of radon and its daughters, instrumentation for their measurement, health effects, surveys and measurements, and regulatory information. The references in the bibliography are sequenced in alphabetical order and abstracts are included when supplied by the author. The objective of this report is to disseminate the bibliographic references compiled at the laboratory relating to radon research portion of the program. Interested database users are encouraged to contact the laboratory to receive instructions for direct database acess. A flyer describing the database is supplied at the end of the bibliography and a brief overview of the Radon Research porgram is given.

  6. Radon: a bibliography

    International Nuclear Information System (INIS)

    Lepman, S.R.; Boegel, M.L.; Hollowell, C.D.

    1981-01-01

    The Lawrence Berkeley Laboratory, with the support of the Department of Energy, has developed a computerized database to manage research information in the area of building ventilation and indoor air quality. This literature survey contains references pertaining to the physical properties of radon and its daughters, instrumentation for their measurement, health effects, surveys and measurements, and regulatory information. The references in the bibliography are sequenced in alphabetical order and abstracts are included when supplied by the author. The objective of this report is to disseminate the bibliographic references compiled at the laboratory relating to radon research portion of the program. Interested database users are encouraged to contact the laboratory to receive instructions for direct database acess. A flyer describing the database is supplied at the end of the bibliography and a brief overview of the Radon Research porgram is given

  7. Radon depth migration

    International Nuclear Information System (INIS)

    Hildebrand, S.T.; Carroll, R.J.

    1993-01-01

    A depth migration method is presented that used Radon-transformed common-source seismograms as input. It is shown that the Radon depth migration method can be extended to spatially varying velocity depth models by using asymptotic ray theory (ART) to construct wavefield continuation operators. These operators downward continue an incident receiver-array plane wave and an assumed point-source wavefield into the subsurface. The migration velocity model is constrain to have longer characteristic wavelengths than the dominant source wavelength such that the ART approximations for the continuation operators are valid. This method is used successfully to migrate two synthetic data examples: (1) a point diffractor, and (2) a dipping layer and syncline interface model. It is shown that the Radon migration method has a computational advantage over the standard Kirchhoff migration method in that fewer rays are computed in a main memory implementation

  8. SELECCIÓN DE BACTERIAS CON CAPACIDAD DEGRADADORA DE HIDROCARBUROS AISLADAS A PARTIR DE SEDIMENTOS DEL CARIBE COLOMBIANO

    OpenAIRE

    Narváez-Flórez, Silvia; L. Gómez, Martha; Martínez, María M.

    2008-01-01

    A partir de sedimentos del Caribe colombiano se realizaron 31 aislamientos bacterianos en medio mínimo de sales suplementado con hidrocarburos (ACPM o petróleo crudo) como única fuente de carbono. Las cepas aisladas se sometieron a pruebas de selección en diferentes concentraciones de hidrocarburos y se escogieron once de ellas tolerantes al crudo y ACPM en un ámbito del 1-8% v/v. Posteriormente, con las cepas seleccionadas, se conformó un cultivo bacteriano mixto y se evaluó su capacidad de ...

  9. Radon -- an environmental hazard

    International Nuclear Information System (INIS)

    Faheem, M.; Rahman, R.; Rahman, S.; Matiullah

    2005-01-01

    Humans have always been exposed throughout its period of experience to naturally occurring sources of ionizing radiation or natural background radiation, It is an established fact that even these low background doses are harmful to man and cause increased cancer risk. About half of our radiation comes from radon, a radioactive gas coming from normal materials in the ground. Several building materials such as granite, bricks, sand, cement etc., contain uranium in various amounts. The radioactive gas /sup 222/Rn produced in these materials due to decay of 226Ra is transported to indoor air through diffusion and convective flow. It seeps out of soil and rocks, well water, building materials and other sources at a varied rate. Amongst the naturally occurring radioisotopes, radon is the most harmful one that can be a cause of lung cancer. Radon isotopes are born by the decay of radium and radium production in turns comes from uranium or thorium decay. For humans the greatest importance among Radon isotopes is attributed to /sup 222/Rn because it is the longest lived of the three naturally produced isotopes. Drinking water also poses a threat. Radon gas is dissolved in water and is released into the air via water faucets, showerheads, etc. the lack of understanding has so far lead to speculative estimates of pollutant related health hazards. (author)

  10. Cost and effectiveness of radon barrier systems

    International Nuclear Information System (INIS)

    Baker, E.G.; Freeman, H.D.; Hartley, J.N.; Gee, G.W.

    1982-12-01

    Earthen, asphalt, and multilayer radon barrier systems can all provide reduction in the amount of radon gas released from uranium mill tailings. Pacific Northwest Laboratory field tested all three types of covers at Grand Junction, Colorado during the summer of 1981. All nine individual radon barrier systems tested currently meet the EPA standard for radon flux of 20 pCi m - 2 s - 1 . The cost of the asphalt and 3m earthen covers were about the same at the field test. Multilayer covers were significantly more costly. Cost estimates for three high priority western sites indicate 3m of earthen cover is the least costly radon barrier when earthen material is available at or near the disposal site. If earthen material must be imported more than 8 to 10 km asphalt and possibly multilayer radon barriers can be cost effective

  11. The 1996 Radon Intercomparison Exercise at PSI

    International Nuclear Information System (INIS)

    Schuler, C.; Butterweck-Dempewolf, G.

    1997-05-01

    The 1996 Radon Intercomparison Exercise at PSI was organized by the PSI Reference Laboratory for Radon Gas Activity Concentration Measurements. A total of 14 laboratories, companies and institutions participated with radon gas detectors and measuring instruments. The detectors and instruments were exposed in the PSI radon chamber during seven days in a reference atmosphere with an average radon gas concentration of about 6000 Bqm -3 . Comparison of the results of electret ionization chambers, track etch detectors and measuring instruments with the PSI target value showed the criteria for traceability and reproducibility demanded by the Federal Office for Health for the acknowledgement of Swiss Radon Gas Measurement Laboratories to be fulfilled for all participants. Exposure of track etch detectors stored for more than one year demonstrated that this detector type can suffer sensitivity loss by a too long storage period. (author) figs., tabs., refs

  12. Deterministic Chaos in Radon Time Variation

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.; Radolic, V.; Faj, Z.; Stanic, D.

    2003-01-01

    Radon concentrations were continuously measured outdoors, in living room and basement in 10-minute intervals for a month. The radon time series were analyzed by comparing algorithms to extract phase-space dynamical information. The application of fractal methods enabled to explore the chaotic nature of radon in the atmosphere. The computed fractal dimensions, such as Hurst exponent (H) from the rescaled range analysis, Lyapunov exponent (λ ) and attractor dimension, provided estimates of the degree of chaotic behavior. The obtained low values of the Hurst exponent (0< H<0.5) indicated anti-persistent behavior (non random changes) of the time series, but the positive values of the λ pointed out the grate sensitivity on initial conditions and appearing deterministic chaos by radon time variations. The calculated fractal dimensions of attractors indicated more influencing (meteorological) parameters on radon in the atmosphere. (author)

  13. Radon time variations and deterministic chaos

    Energy Technology Data Exchange (ETDEWEB)

    Planinic, J. E-mail: planinic@pedos.hr; Vukovic, B.; Radolic, V

    2004-07-01

    Radon concentrations were continuously measured outdoors, in the living room and in the basement at 10 min intervals for a month. Radon time series were analyzed by comparing algorithms to extract phase space dynamical information. The application of fractal methods enabled exploration of the chaotic nature of radon in atmosphere. The computed fractal dimensions, such as the Hurst exponent (H) from the rescaled range analysis, Lyapunov exponent ({lambda}) and attractor dimension, provided estimates of the degree of chaotic behavior. The obtained low values of the Hurst exponent (0radon time variations. The calculated fractal dimensions of attractors indicated more influencing (meteorological) parameters on radon in the atmosphere.

  14. Radon time variations and deterministic chaos

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.; Radolic, V.

    2004-01-01

    Radon concentrations were continuously measured outdoors, in the living room and in the basement at 10 min intervals for a month. Radon time series were analyzed by comparing algorithms to extract phase space dynamical information. The application of fractal methods enabled exploration of the chaotic nature of radon in atmosphere. The computed fractal dimensions, such as the Hurst exponent (H) from the rescaled range analysis, Lyapunov exponent (λ) and attractor dimension, provided estimates of the degree of chaotic behavior. The obtained low values of the Hurst exponent (0< H<0.5) indicated anti-persistent behavior (non-random changes) of the time series, but the positive values of λ pointed out the grate sensitivity on initial conditions and the deterministic chaos that appeared due to radon time variations. The calculated fractal dimensions of attractors indicated more influencing (meteorological) parameters on radon in the atmosphere

  15. Radon programme in Czech Republic. Results, experience and future

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.; Fojtikova, I.; Vlcek, J.; Moucka, L.; Fronka, A.; Jilek, K.; Heribanova, A.; Slovak, J.; Barnet, I.; Burian, I.; Jiranek, M.; Cechak, T.

    2004-01-01

    The beginning of the radon programme in the Czech republic dates back to the early 1980s. Incorporated in national legislation (Atomic Act, Radiation Protection Decree), the programme includes now both preventive measures and interventions. Preventive measures are based on the control of major potential radon sources (soil gas, building material and supplied water) to prevent construction of new houses where the recommended indoor radon level of 200 Bq/m 3 would be exceeded. Radon risk (index) assessment of the individual building site bedrock in the case of new house siting and building protection as stipulated by the technical building code are obligatory. The estimation of the radon-related index of building sites is based on a standard method involving a set of radon soil and soil permeability measurements. In addition, producers of building materials are obligated to monitor natural radioactivity in their products. The activity index (including 40 K, 226 Ra and 232 Th) is used as a screening level for regulation of the potential indoor gamma dose rate, and the 226R a mass activity is used as a limiting value for radon exhalation. A similar regulatory system is in place for public water supplies based on obligatory radon, total alpha and total beta measurements. A survey of effectiveness of the preventive measures was carried out during the past years. It appeared, however, that the indoor radon level of 200 Bq/m 3 is exceeded in some 20 % of new houses. An unexpectedly low air exchange rate in modern energy-saving houses seems to be among the reasons. Remedial actions are aimed at promoting targeted indoor radon survey in existing buildings and helping owners to put reasonable remedial measures into effect. Governmental activities include representative and targeted indoor radon survey, subsidies for remediation measures and test measurements, and improving the level of public awareness of the radon issue. Indoor radon survey is targeted on radon-prone areas

  16. Large-scale radon hazard evaluation in the Oslofjord region of Norway utilizing indoor radon concentrations, airborne gamma ray spectrometry and geological mapping

    International Nuclear Information System (INIS)

    Smethurst, Mark Andrew; Strand, Terje; Sundal, Aud Venke; Rudjord, Anne Liv

    2008-01-01

    We test whether airborne gamma ray spectrometer measurements can be used to estimate levels of radon hazard in the Oslofjord region of Norway. We compile 43,000 line kilometres of gamma ray spectrometer data from 8 airborne surveys covering 10,000 km 2 and compare them with 6326 indoor radon measurements. We find a clear spatial correlation between areas with elevated concentrations of uranium daughters in the near surface of the ground and regions with high incidence of elevated radon concentrations in dwellings. This correlation permits cautious use of the airborne data in radon hazard evaluation where direct measurements of indoor radon concentrations are few or absent. In radon hazard evaluation there is a natural synergy between the mapping of radon in indoor air, bedrock and drift geology mapping and airborne gamma ray surveying. We produce radon hazard forecast maps for the Oslofjord region based on a spatial union of hazard indicators from all four of these data sources. Indication of elevated radon hazard in any one of the data sets leads to the classification of a region as having an elevated radon hazard potential. This approach is inclusive in nature and we find that the majority of actual radon hazards lie in the assumed elevated risk regions

  17. Working towards residential Radon survey in South America

    International Nuclear Information System (INIS)

    Zielinski, Jan M.; University of Ottawa, ON; Canoba, Analia C.; Shilnikova, Natalia S.; Veiga, Lene H. S.

    2008-01-01

    Information about residential radon levels in low and middle income countries is very sparse. In response to the World Health Organization initiative in the International Radon Project, we propose a research project that will address this knowledge gap in South America by conducting a residential radon survey. Following initial in vitro and in vivo studies of radon and studies of uranium miners exposed to radon, over twenty large case-control studies of lung cancer risk from exposure to residential radon have been completed worldwide by year 2004. Recently pooled data from these individual studies have been analyzed. These collaborative analyses of the indoor studies in Europe, North America, and China provide strong direct evidence that radon is causing a substantial number of lung cancers in the general population. To reduce radon lung cancer risk, national authorities must have methods and tools based on solid scientific evidence to develop sound public health policies. We propose to conduct a survey in ten South American countries using the distribution and analysis of passive alpha tracking detectors in houses selected at random in pre-selected cities in each participating country. We also present an approach to estimate the cost of carrying out such a survey and the radon laboratory infrastructure needed. The results of the proposed survey will allow to conduct assessment of the exposure to residential radon in the populations of South American countries and to assess the health impact of this exposure. The results of the project will also help national health authorities in developing national residential radon action levels and regulations, as well as provide public health guidance for radon awareness and mitigation. (author)

  18. Draft of „National Radon Programme” 2013-2017

    International Nuclear Information System (INIS)

    Ivanova, K.; Badulin, V.; Georgieva, R.

    2013-01-01

    The World Health Organization defines radon as the second most important causal factor for lung cancer after smoking and the number one factor for people who have never smoked. The draft of the new European Directive takes accounts the latest ICRP Recommendations for reducing radon exposure in buildings. The Directive requires Member States to bring into force the laws, regulations and administrative provisions. The main goal of „National Radon Programme” is establishment and implementation of long-term policy to reduce and prevent risks of public health resulting from exposure to high concentrations of indoor radon in buildings. To achieve this are required: – to establish an appropriate system; – to carry out national survey and mapping of areas with radon background; – to establish radon prevention strategies in newly constructed buildings and radon mitigation strategies in existing buildings; – to improve public awareness; – to lay down a system for protection against radon in workplaces. The implementation of the program will contribute to reducing the public exposure due to indoors due to radon. Along with the reduction of smoking, it will directly and indirectly improve the prevention of lung cancer risks. (author)

  19. Health hazards due to radon and its daughters

    International Nuclear Information System (INIS)

    Khan, H.A.; Qureshi, I.E.; Tufail, M.

    1993-01-01

    The health hazards liked to radon and its daughters have become a matter of great public concern. When inhaled, a fraction of radon is dissolved into the lung fluid, from where it is transported to other parts of the body. The radiation damage is caused to the lungs due to alpha decay of radon during its transit time within the respiratory tract. Radon daughters are found to be even more dangerous than radon itself. These daughters attach themselves to dust particles present in the air. Some of the aerosols so produced enter the lungs and enter the blood stream. It has now been confirmed that radon and its daughters contribute about 70% of the internal dose received by an individual from natural radiation sources. The danger of indoor radon and its daughters is even higher for energy-saving houses and those having poor ventilation systems. This paper briefly describes the health hazards due to radon and its daughters. Different methods employed for the measurement of concentrations of radon and their daughters are described. The experience gained from the nation-wide surveys carried out in different countries is also given. (author). 18 refs, 3 figs, 1 tab

  20. Radon concentration in a house of Calvados

    International Nuclear Information System (INIS)

    Leleyter, L.; Riffault, B.; Mazenc, B.

    2010-01-01

    Recent studies indicate a link between the risk of lung cancer and residential radon exposure. However, in France, awareness of this problem was made relatively late. Accordingly this study examines the radon concentration in a private home in Calvados (Normandy region). Findings show that the presence of a fireplace in a house can accelerate radon convective transfer, and that simple adjustments to interior and exterior accommodation can significantly reduce radon concentrations in the home. (authors)