WorldWideScience

Sample records for con eco-doppler color

  1. Análisis de perforantes de la epigástrica inferior profunda con Angio TC 3D, Eco Doppler color y Doppler simple de ultrasonidos en colgajo DIEP: resultados preliminares Analysis of deep inferior epigastric perforating vessels with 3D CT angiography, color Doppler ultrasonography and Doppler in diep flaps: preliminary results

    Directory of Open Access Journals (Sweden)

    J. Castro García

    2008-09-01

    Full Text Available Nuestro objetivo es la validación de la Angio TC tridimensional como herramienta de planificación de los colgajos DIEP, comparándolo con el Doppler de ultrasonidos (US y eco Doppler color. Entre enero de 2006 y marzo de 2007 se realiza en 11 pacientes (13 DIEP un estudio comparativo prospectivo entre el Doppler de US, eco Doppler color y Angio TC con reconstrucción tridimensional, utilizando como dato de referencia los hallazgos intraoperatorios. En dicho proceso se localiza la mejor perforante que pueda servir como pedículo al colgajo DIEP en función de su localización, calibre, trayecto y relaciones anatómicas con respecto al músculo. La Angio TC con reconstrucción tridimensional, demuestra una especificidad del 100% (IC 95% 75.3-100 lo que le convierte en una prueba con un alto valor predictivo positivo y una excelente herramienta en la planificación de los colgajos de perforantes. El eco Doppler color determinó, que tan sólo en un 46,1% (IC 95% 19,2-74,9 de los pacientes, la perforante seleccionada por la prueba de forma preoperatoria, coincidía con la perforante elegida en quirófano. Con el Doppler de US, en un 30,8 % (IC 95% 9,1-61,4 de los colgajos estudiados, coincidía la mejor perforante escogida de forma preoperatoria, con los hallazgos obtenidos tras la disección del colgajo. En el presente estudio, la Angio TC tridimensional se ha mostrado como una técnica con una gran especificidad que proporciona valiosa información, sólo comparable con la disección anatómica y por delante de pruebas como el Doppler de ultrasonidos y el eco Doppler color.The aim of this report, is to validate the Angio-CT technique with three-dimentional reconstruction as a preoperative planning tool, after comparison with Doppler ultrasound and color- Duplex. Between january 2006 and march 2007, we studied 11 consecutive patients (13 DIEP in whom a prospective comparative followed up was performed comparing, the findings observed using

  2. Identificação pelo eco-Doppler colorido de fístula arteriovenosa na trombose venosa profunda Arteriovenous fistula in deep venous thrombosis identified by color-flow Doppler ultrasonography

    Directory of Open Access Journals (Sweden)

    Fanilda Souto Barros

    2006-09-01

    Full Text Available Os três casos são referentes a pacientes em tratamento para trombose venosa profunda encaminhados ao laboratório vascular para avaliação da recanalização e/ou progressão do processo trombótico. Durante o estudo pelo eco-Doppler colorido, foram identificados sinais ecográficos compatíveis com fístula arteriovenosa no interior do trombo e adjacente à parede venosa.We report on a case series of three patients undergoing treatment for deep venous thrombosis, referred to our vascular laboratory for evaluation of recanalization and/or progression of the thrombotic process. During the color-flow Doppler ultrasonography, we identified ultrasound signs typical of arteriovenous fistula flow pattern within the thrombus and adjacent to the venous wall.

  3. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  4. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  5. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  6. Mismatch paciente-prótesis aórtica. Comparación alejada por eco-Doppler transtorácico versus el estimado en el preoperatorio

    Directory of Open Access Journals (Sweden)

    Gabriel Converso

    2008-01-01

    Full Text Available Introducción:El mismatch paciente-prótesis (MPP aórtica se asocia con peor evolución posoperatoria.La utilización del área del orificio aórtico efectivo (AOE para cada tipo de prótesis, indexado por la superficie corporal (SC en el momento quirúrgico, puede permitir la elección de un tamaño de prótesis adecuado para cada paciente y así evitar el MPP.ObjetivoComparar la estimación de MPP por las AOE tabuladas con la diagnosticada en el posoperatorio alejado por eco-Doppler.Material y métodosSe analizaron retrospectivamente 57 pacientes, 43 hombres, con prótesis aórtica, operados más de 6 meses antes del estudio. Se calculó la SC del parte quirúrgico y el AOE indexada tabulada, el AOE posquirúrgica con eco-Doppler transtorácico por la ecuación de continuidad y se comparó el MPP prequirúrgico y posquirúrgico. Se consideró MPP aórtico un AOE indexada < 0,75 cm2/m2.ResultadosSe observó una prevalencia de MPP preoperatorio del 29,8% y posoperatorio del 54,4% (p = 0,029, con el 31% de MMP grave. La prevalencia de sobrepeso en la muestra estudiada fue del 80%.ConclusionesEn este grupo de pacientes con alta prevalencia de sobrepeso, la estimación del AOE preoperatoria indexada por SC de cada tipo de prótesis para predecir el MPP posoperatorio mostró diferencias significativas entre el diagnóstico del MPP estimado en el preoperatorio y el calculado por eco-Doppler en el posoperatorio. En futuros estudios es necesaria la inclusión de un grupo poblacional mayor, así como la revisión del método de cálculo del área valvular (p. ej., del tracto de salida del ventrículo izquierdo.

  7. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  8. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  9. Temporal enhancement of two-dimensional color doppler echocardiography

    Science.gov (United States)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  10. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  11. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  12. Spectral color Doppler in the diagnosis and follow-up of Graves` disease; Ruolo dell`eco color Doppler e dell`analisi flussimetrica nella diagnosi e nel follow-up della malattia dei Graves

    Energy Technology Data Exchange (ETDEWEB)

    Sponza, Massimo; Bertolotto, Michele; Ricci, Claudio [Ospedale di Cattinara, Trieste (Italy). Istituto di Medicina Clinica; Fabris, Bruno; Armini, Lorenzo [Ospedale di Cattinara, Trieste (Italy). Istituto di Radiologia

    1997-04-01

    Hyperthyroidism in Graves` disease is caused by the presence of circulating autoantibodies to the THS receptors on the thyroid cells. Thyroid-suppression therapy prevents hormone production directly, without affecting the pathogenetic process. They performed color Doppler US of the thyroid gland and pulsed Doppler analysis of thyroid artery flow in 21 patients with Graves` disease before and during medical treatment. US results were compared with those of a control group of 40 healthy subjects and correlated with the values of thyroid hormones, TSH and thyroid microsomal and thyroglobulin antibodies. The thyroid gland was hypo vascularized in the control group. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity of PSV 20 {+-} 4 cm/s, diastolic velocity of 8 {+-} 1 cm/s, and resistive index of 0.60 {+-} 0.04. The thyroid gland of Graves` disease patients was hyper vascularized. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity (PSV = 51 {+-} 12 cm/s), end diastolic velocity (VD = 15 {+-} 4 cm/s) and resistive index (RI = 0.71 {+-} 0.04) significantly higher than in normal subjects (p < 0.001). Circulating thyroid hormones and flow parameters normalized after 6-8 months of medical therapy (PSV = 20 {+-} 6 cm/s, VD = 9 {+-} 3 cm/s, RI = 0.58 {+-} 0.07). The color Doppler patterns normalized only in a patient with normal TSH and antibodies. Sampling of the thyroid arteries proved more repeatable than sampling of parenchymal vessels.

  13. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Sam Soo [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2009-12-15

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  14. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    International Nuclear Information System (INIS)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee; Kim, Sam Soo

    2009-01-01

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  15. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  16. Acute intrascrotal pathology in childhood: color Doppler study

    International Nuclear Information System (INIS)

    Cinta Sanguesa, C.; Muro, D.; Cortina, H.; Moreno, A.

    1997-01-01

    To asses the utility of color Doppler ultrasound in the study of acute intrascrotal pathology in childhood. Seventy-five boys with evidence of an acute intrascrotal abnormality were studied by means of color Doppler ultrasound. A 7.5 MHz linear transducer was used. The most common findings was inflammatory disease (60%) which was indicated by the presence of hyperemia in color Doppler. Of the nine boys with testicular torsion (12%) two presented extravaginal torsion, with a complete absence of intratesticular vascularization. Intravaginal torsion was observed in seven patients, six of whom presented reduced vascularization in the abnormal testicle with respect to the healthy testicle. There was one false negative in which testicular vascularization was normal but 360 degree centigree torsion was found at surgery. In addition, there were seven cases of hydatid torsion (9.33%), four of idiopathic scrotal swelling (5.3%). two cases of intermittent torsion (2.6%) and one case of Shcolein-Henoch purpura (1.3%). The ultrasound findings were completely nornal in seven boys. Color Doppler is a rapid, noninvasive method for assessing testicular blood flow. The elevated sensitivity and specificity (85.7 and 100%, respectively, in our series) for testicular torsion make Doppler ultrasound a highly reliable method for the study of this disorder. (Author) 18 refs

  17. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of); Hwang, Hee Yong [Choong Ang Gil Hospital, Incheon (Korea, Republic of)

    1995-06-15

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  18. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    International Nuclear Information System (INIS)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan; Hwang, Hee Yong

    1995-01-01

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  19. Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.

    Science.gov (United States)

    Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P

    1995-01-01

    Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.

  20. Evaluating Peripheral Vascular Injuries: Is Color Doppler Enough for Diagnosis?

    Directory of Open Access Journals (Sweden)

    Mohd Lateef Wani

    2014-03-01

    Full Text Available Background:: Vascular injury poses a serious threat to limb and life. Thus, diagnosis should be made immediately with minimally invasive methods. Doppler is a good aid in diagnosis of vascular injury. Methods:: The present prospective study was conducted on 150 patients who presented with soft signs (the signs which are suggestive but not confirmatory of vascular injury. They were subjected to color Doppler examination before exploration. The patients with the features of vascular injury on color Doppler were subjected to exploration. On the other hand, those who had normal Doppler were subjected to CT- angiography. Then, the findings of the exploration were matched with those of color Doppler. The data were analyzed using the SPSS statistical software. Results:: Out of the 150 Doppler examinations, 110 (73.33% were reported as positive, while 40 were reported as negative for vascular injury. These were subjected to CT-angiography and seven of them had the features of vascular injury on CT-angiography. All the patients with positive Doppler or CT angiography findings were subjected to exploration. Doppler had a sensitivity of 94% and specificity of 82.5% in diagnosis of vascular injury using Binary classification test. Conclusions:: Color Doppler is an easily available, reliable, and handy method of diagnosing a vascular injury. It has a very high sensitivity and specificity in diagnosis of vascular injuries.

  1. Contrast-enhanced power Doppler US in the characterization of renal masses; Power Doppler con mezzo di contrasto nella caratterizzazione delle masse renali

    Energy Technology Data Exchange (ETDEWEB)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E. [Messina Univ., Messina (Italy). Ist. di Scienze Radiologiche

    2000-09-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts. [Italian] Scopo di questo articolo e' quello di riportare i risultati di uno studio prospettico finalizzato ad individuare le potenzialita' del power Doppler con mdc ecografico nella caratterizzazione delle lesioni espansive del rene. Dal 1997 al 30 ottobre 1999 sono state studiate 59 lesioni renali (28 maligne, 31 benigne) in 48 pazienti (eta' media 55 anni, intervallo 10

  2. Magnetic angioresonance of the carotid artery: correlation with color Doppler ultrasound

    International Nuclear Information System (INIS)

    Cotilla, J.; Miralles, M.; Cairols, M.C.; Dolz, J.L.; Vilanova, J.C.; Capdevila, A.

    1998-01-01

    To determine the value of magnetic angioresonance (MAR) in grading carotid stenosis, comparing it with color Doppler and intraarterial digital subtraction angiography (IADSA). A comparative study using color Doppler and MAR was carried out in 84 patients with coratid lesions. Fifty-two of the patients underwent angiographic study as well. The comparison of MAR versus arteriography in discriminating stenosis of more than 70%, expressed in terms of sensitivity specificity, overall precision and the kappa concordance index, gave values of 87.2, 90.8, 89.4 and 0.78%, respectively. When MAR was compared with color Doppler, the results were 86.8, 85.9, 86.3 and 0.72%, respectively. The results of the comparison between color Doppler and arteriography were 82.2, 86.2, 84.6 and 0.68%, respectively. The better correlation of MAR, as compares with angiography and color Doppler, with the grade of carotid stenosis indicates the high degree of reliability. The better correlation of MAR, as compares with angiography and color Doppler, with the grade of carotid stenosis indicates the high degree of reliability of this imaging technique. (Author) 29 refs

  3. Gestational trophoblastic neoplasia: efficacy of color doppler ultrasound

    International Nuclear Information System (INIS)

    Song, Sun Wha; Jee, Won Hee; Choe, Bo Young; Byun, Jae Young; Choi, Byung Gil; Shinn, Kyung Sub

    1997-01-01

    To evaluate the efficacy of color Doppler ultrasound (US) in the diagnosis of gestational trophoblastic neoplasia (GTN). Intralesional color flows and resistive index (RI) on color Doppler US were prospectively analyzed in 21 consecutive suspected GTN cases. RI of the intralesional artery was investigated on the basis of the presence or absence of mass and metastasis. Correlation between RI of intralesional artery and urinary β-hCG was also investigated. Intralesional color flows were identified in 15 patients with GTN. On operation, intralesional color flows were observed in one of two patients in whom the presence of completely necrotic tissue was confirmed. Intralesional color flows, however, were not detected in four patients who were proved not to be GTN sufferers. Sensitivity, specificity, accuracy, positive and negative predictive values, and accuracy were 100%, 83%, 95%, 94% and 100%, respectively. Significant correlation between RI of the intralesional artery and urinary β-hCG was not established (p=0.49, r=0.19). RI of this artery was not substantially different between groups with and without mass, and between groups with and without metastasis (p=0.32, p=0.82). The current study demonstrates that color Doppler US is a sensitive and useful method for the diagnosis of GTN

  4. Color doppler ultrasound diagonosis in cesarean scar pregnancy

    International Nuclear Information System (INIS)

    Chen Shanshan; Xia Fei; Shen Zongji; Xu Jianyin; Gu Xinxian

    2010-01-01

    Objective: To study the sonographic characteristics of cesarean scar pregnancy(CSP), and the value of color Doppler in the diagnosis of CSP. Methods: Twelve cases of CSP were all confirmed by transabdominal and transvaginal ultrasound. Results: The ultrasonogram of CSP could be divided into gestational sac type and mixed mass type. Conclusion: Color Doppler can give guidance to the early diagnosis, treatment and following-up of CSP because of the sonographic specifity of CSP. (authors)

  5. Color Doppler flow mapping of stenotic and regurgitant natural heart valves

    International Nuclear Information System (INIS)

    Nanda, N.C.

    1986-01-01

    Color Doppler echocardiography has found widest application in reliable detection and assessment of severity of both atrio-ventricular and semi-lunar valve incompetence. The authors believe both the sensitivity and specificity of color Doppler for the detection of mitral and aortic regurgitation is very high in patients with adequate acoustic windows. In 82 patients with proven mitral regurgitation studied, the best correlations with angiography were noted when the maximum or average regurgitant jet are obtained by color Doppler from three standard 2-D echo planes (parasternal long and short axis and apical four chamber view) and expressed as a percentage of the left atrial area were considered. The criteria the authors used for assessment of tricuspid and pulmonary valve incompetence are similar to those used for mitral and aortic valve incompetence, but the lack of a good ''gold'' standard has hampered validation. The color Doppler technique also supplements conventional Doppler in the assessment of severity of stenotic lesions by facilitating parallel alignment of the continuous wave Doppler cursor line with the stenotic jet for accurate recording of maximal velocities and pressure gradients. The authors have found this method especially useful in the assessment of aortic stenosis. In conclusion, color Doppler flow mapping combined with conventional echocardiography provides, for the first time, a comprehensive noninvasive assessement of the severity of regurgitant and stenotic lesions

  6. Endosonographic and color doppler flow imaging alterations observed within irradiated rectal cancer

    International Nuclear Information System (INIS)

    Alexander, Archie A.; Palazzo, Juan P.; Ahmad, Neelofur R.; Liu, J.-B.; Forsberg, Flemming; Marks, John

    1996-01-01

    Purpose: To correlate the endosonographic and color Doppler flow imaging alterations observed in irradiated rectal cancers with the pathologic features of radiation response, and to evaluate the potential impact of altered blood flow on the integrity of the surgical anastamosis. Methods and Materials: Endosonography with color and pulsed wave Doppler was performed on 20 rectal cancer masses before and after high dose preoperative radiation (XRT). Pre- and post-XRT observations included comparing alterations in tumor size, sonographic echotexture, color Doppler flow, and pulsatility indices. Comparisons were made with pathologic findings in the irradiated specimens and with the incidence of anastomotic failure. Results: Compared to pre-XRT observations, irradiated rectal cancers decreased in size and became either mixed in echogenicity with less apparent color Doppler flow (16 of 20) or unchanged in color Doppler flow and echotexture (4 of 20). Those with less flow (16 of 20) were imaged later (mean = 90.2 ± 12.1 days) than those without change in color Doppler flow (mean = 21.7 ± 2.7 days). Pathologically, the group of four without change in color Doppler signal had features of acute inflammation which were not observed in 16 of 20 imaged later. Based on pulsatility index measurements, both high and low resistance vessels were detected and confirmed by immunohistochemical staining, and features of postradiation obliterative vasculitis were observed. Only one primary anastomosis in 14 patients with decreased flow failed. Conclusions: The sonographic and color Doppler flow imaging alterations observed within irradiated rectal cancer correlated with changes of postradiation obliterative vasculitis. The apparent diminished local blood flow within high and low resistance vessels post-XRT did not result in an increased incidence of anastomotic failures

  7. Phylloedes tumor of breast: findings at mammography, sonography and color Doppler imaging

    International Nuclear Information System (INIS)

    Park, Kun Choon; Ahn, Sei Hyun; Kim, Young Hwan; Choi, Hye Yong; Baek, Seung Yon; Yoon, Jeong Hyun

    1994-01-01

    The phylloides tumor of the breast is rare. the purposes of this study were to find the characteristic findings at mammography, sonography, and color Doppler imaging and to evaluate the usefulness of color Doppler study as an additional modality in the diagnosis of phylloides tumor and differentiation between benign and malignant varieties. Eight cases, who were pathologically proven as pylloides tumors, were retrospectively studied. The findings at histologic examination suggested benign in five, malignantin two, and borderline in one. We analyzed the mammograms of all eight patients and sonogram and color Doppler images of four patients. Phylloides tumors were seen as dense masses with lobulated margins in mammograms. On sonography, they showed relatively well-defined masses with in homogenous internal echo pattern and central echogenic areas. They were characterized by the presence of arterial and venous flows in the center and periphery of the lesion on color Doppler imaging and spectral analysis. We conclude that mammographic, sonographic and even color Doppler findings are not predictive of benign or malignant nature of the phylloides tumor. However, mammography and sonography with color Doppler interrogation are helpful in the diagnosis of phylloides tumor

  8. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  9. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of); Hwang, Hee Yong [Choong Ang Gil Hospital, Incheon (Korea, Republic of)

    1995-06-15

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  10. The Role of Color Doppler Ultrasonography in Characterization of Thyroid Tumors

    International Nuclear Information System (INIS)

    Kim, Hee Soo; Jeon, Pyong; Won, Jong Yoon; Na, Jae Beom; Lee, Hyang Mee; Yoo, Hyung Sik; Lee, Jong Tae; Park, Jeong Soo; Cho, Nam Hoon

    1995-01-01

    To assess the usefulness of color Doppler ultrasonography in the characterization of thyroid tumors, surgically proven 88 nodules in 85 patients were evaluated. Using 10 MHz linear array transducer, gray scale images were initially evaluated. Then, distribution pattern of color signals (marginal, intra-tumoral, mixed) and graded internal vascularity according to morphology of color signal (0:absence of internal signal, 1: spotty, 2: linear,3: branching) were observed on color doppler imaging. Pulsed doppler waves were analyzed with parameters including peak systolic velocity(PSV), resistive index(RI), and pulsatile index(PI). Significantly larger numbers of intra-tumoral type, 20 cases(62.5%), were observed in malignant nodules, whereas mixed forms were predominant in benign group, 37 cases (66%) In graded internal vascularity, malignant nodules tended to have grade 2 or 3 signals, whereas benign nodules tended to have grade 0 or 1 signals. Spectral wave analysis show no significant difference in the value of PSV, RI, and PI between malignancy and benignity group. In conclusion, color Doppler imaging has a potential role in the characterization of thyroid nodules as a supportive method for gray scale diagnosis

  11. Vesico-ureteral reflux: diagnosis and staging with voiding color doppler US Preliminary experience

    International Nuclear Information System (INIS)

    Farina, Renato; Arena, Carmela; Pennisi, Francesco; Di Benedetto, Vincenzo; Politi, Guido; Di Benedetto, Aurelio

    2000-01-01

    Introduction: The aim of this study is to assess the accuracy of a new US examination: 'voiding color Doppler US ' in the early diagnosis and staging of vesico-ureteral reflux (VUR). The contrast agent US was SH U 508A (Levovist, Schering, Berlin), which produces a chromatic accentuation of the signals picked up by the color Doppler US. Eighteen patients (10 females, eight males) were recruited for the study. In two patients a second examination was performed for follow-up after a VUR conservative therapy. All patients were taken under examination for the evaluation of possible VUR. In all patients the voiding color Doppler US was followed by voiding cystourethrography (VCUG) and the data obtained were compared. Materials and methods: A total of 18 patients aged between 3 months and 10 years, were recruited for the study. The results of the examination were the following: urinary tract infections, follow-up of VUR after conservative or surgical therapy, miscellaneous indications. Voiding color Doppler US was performed, followed by a VCUG. The voiding color Doppler US consists in the trans-catheter introduction of a contrast agent SHU 508 A (Levovist, Schering, Ag. Berlin) into the bladder and a subsequent test with the color Doppler US to show or exclude the presence of reflux into the ureters and/or into the pyelo-caliceal cavity of the kidneys. After the introduction of the contrast agent US the ultrasound scanning of the bladder, the ureters and the pyelo-caliceal cavity was performed to examine the reflux degree. The ultrasonographic investigations were perfomed with AU 590 asyncronus US (Esaote Biomedica, Genova) with a 3.5 MHz convex probe. Results: After the trans-catheter introduction of the contrast agent US, vesico-ureteral reflux occured in 13 patients (77.2%). The reflux degree was also measured by means of ultrasound and was later confirmed by VCUG. The mean times of each examination were as follows: initial US, 10 min; catheterization, 8 min; voiding

  12. The color Doppler ultrasonography in in the diagnosis of deep vein thrombosis

    International Nuclear Information System (INIS)

    Ameneiro Perez, Santiago; Alvarez Sanchez, Jose A.; Rodriguez Villalonga, Luis; Borras Migues, Marisela; Quinnones Castro, Mayda

    2004-01-01

    The paper was aimed at evaluating the accuracy of color Doppler ultrasonography, a noninvasive method, in the diagnosis of deep vein thrombosis of the lower limbs, comparing it to the results of the cruel and costly diagnostic g olden rule , that is, phlebography. Methods: Color Doppler ultrasonography served to assess 102 patients clinically suspected of deep vein thrombosis of the lower limbs, taking into account the following criteria: vein compressibility, echographic images, color, Vein Doppler signal modulation after several maneuvers and distal compression. Sensitivity, specificity, positive and negative predictive values and diagnostic efficacy were estimated for each criteria, taking the phlebography as a reference. Results: Total or partial lack of vein compressibility combined with the vein flow evaluation is the ultrasonographic criterion that reveals higher degree of sensitivity, specificity and efficacy (0,98; 0,95 and 0,97 respectively. Color Doppler ultrasonography is a highly effective noninvasive diagnostic method that detects deep vein thrombosis in proximal areas of the lower limbs

  13. Ultrasonographic investigation of the Achilles tendon in elite badminton players using color Doppler.

    Science.gov (United States)

    Boesen, Morten Ilum; Boesen, Anders; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren

    2006-12-01

    The most frequent injuries in badminton players are in the lower extremities, especially in the Achilles tendon. The game of badminton may be related to abnormal intratendinous flow in the Achilles tendon as detected by color Doppler ultrasound. To a certain extent, this blood flow might be physiological, especially when examined after match. Cohort study (prevalence); Level of evidence, 3. Seventy-two elite badminton players were interviewed regarding Achilles tendon pain (achillodynia) in the preceding 3 years. Color Doppler was used to examine the tendons of 64 players before their matches and 46 players after their matches. Intratendinous color Doppler flow was graded from 0 to 4. The Achilles tendon was divided into dominant (eg, right side for right-handed players and vice versa) and nondominant side and classified as midtendon, preinsertional, and calcaneal areas. Of 72 players, 26 had experienced achillodynia in 34 tendons, 18 on the dominant side and 16 on the nondominant side. In 62% of the players with achillodynia, the problems had begun slowly, and the median duration of symptoms was 4 months (range, 0-36 months). Thirty-five percent had ongoing pain in their tendons for a median duration of 12 months (range, 0-12 months). Achillodynia was not associated with the self-reported training load or with sex, age, weight, singles or doubles players, or racket side. Forty-six players were scanned before and after match. At baseline, color Doppler flow was present in the majority of players, and only 7 (16%) players had no color Doppler flow in either tendon. After match, all players had some color Doppler flow in 1 or both tendons. Achillodynia and color Doppler flow were related in the nondominant Achilles tendon (chi-square, P = .008). The grades of Doppler flow also increased significantly after match in the preinsertional area in both the nondominant (P = .0002) and dominant (P = .005) side tendons. A large proportion of the players had experienced

  14. The use of contrast-enhanced color doppler ultrasound in the differentiation of retinal detachment from vitreous membrane

    International Nuclear Information System (INIS)

    Han, Sang Suk; Chang, Seung Kook; Yoon, Jung Hee; Lee, Young Joon

    2001-01-01

    To compare the clinical utility of contrast-enhanced color Doppler US in the differentiation of retinal detachment (RD) from vitreous membrane (VM) with that of various conventional US modalities, and to analyze the enhancement patterns in cases showing an enhancement effect. In 32 eyes examined over a recent two-year period, RD (n=14) and VM (n=18) were confirmed by surgery (n=28) or clinical follow-up (n=4). In all cases, gray-scale, color Doppler, and power Doppler US were performed prior to contrast injection, and after the intravenous injection of Levovist (Schering, Berlin) by hand for 30 seconds at a dose of 2.5 g and a concentration of 300 mg/mL via an antecubital vein, contrast-enhanced color Doppler US was performed. At Doppler US, the diagnostic criterion for RD and VM was whether or not color signals were visualized in membranous structures. Diagnostic accuracy was 78% at gray-scale US, 81% at color Doppler US, 59% at power Doppler US, and 97% at contrast-enhanced color Doppler US. The sensitivity of color Doppler US to color signals in RD increased from 57% to 93% after contrast enhancement. The enhancement patterns observed were signal accentuation (n=3), signal extension (n=2), signal addition (n=3), and new signal visualization (n=5). Contrast-enhanced color Doppler US was the most accurate US modality for differentiating RD from VM, showing a significantly increased signal detection rate in RD

  15. Discrimination between pleural thickening and minimal pleural effusion using color Doppler chest ultrasonography

    Directory of Open Access Journals (Sweden)

    Ali A. Hasan

    2013-07-01

    Conclusions: Application of color Doppler examination increases the accuracy of real time chest ultrasound to discriminate pleural thickening from minimal pleural effusion and hence color Doppler examination proved to be a useful diagnostic tool to real-time gray-scale ultrasound for diagnosis of minimal pleural effusion.

  16. Color Doppler Score: A New Approach for Monitoring a Large Placental Chorioangioma

    Directory of Open Access Journals (Sweden)

    Maria Angelica Zoppi

    2014-01-01

    Full Text Available We employed color Doppler score as an innovative approach for the prenatal diagnosis and monitoring of a large placental chorioangioma case diagnosed at 26 weeks and the subjective semiquantitative assessment of the vascularization. The blood flow was assessed by a color Doppler score based on the intensity of the color signal with the following value ranges: (1 no flow, (2 minimal flow, (3 moderate flow, and (4 high vascular flow. Weekly examinations were programmed. Initially, a color Doppler score 3 was assigned, remaining unchanged at the following two exams and decreasing to Score 2 in the following 2 exams and to Score 1 thereafter. The ultrasonographic scan showed an increase of the mass size at the second and third exams and was followed by an arrest of the growth persisting for the rest of the pregnancy. Some hyperechogenic spots inside the mass appeared at the end. Expectant management was opted for, and the delivery was at 39, 2 weeks and maternal and fetal outcomes were favourable. The color Doppler score employed for assessment of vascularization in successive examinations proved to be an important tool for the prediction of the chorioangioma involution, and this new approach of monitoring allowed effective surveillance and successful tailored management.

  17. Ultrasonic Doppler color in glaucoma: Concordance study

    International Nuclear Information System (INIS)

    Uriza, Felipe; Useche, Nicolas

    2005-01-01

    Our study demonstrates that US color Doppler is a non invasive, reliable and reproducible method for the evaluation of the orbitary flow in normal and glaucomatous patients. However is suggested that every group evaluates the inter and intraobserver variability because of the lack of universal reference velocity measurements

  18. Color Doppler Ultrasonography-Targeted Perforator Mapping and Angiosome-Based Flap Reconstruction

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Tei, Troels; Thomsen, Jørn Bo

    2016-01-01

    Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap reconstr......Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap...

  19. Alveolar Echinococcosis of the Liver: Correlative Color Doppler US, CT, and MRI Study

    International Nuclear Information System (INIS)

    Cokun, A.; Oeztuerk, M.; Karahan, O.I.; Erdogan, N.; Ikin, S.; Guelec, M.

    2004-01-01

    Purpose: To determine and compare the imaging features of hepatic alveolar Echinococcosis using color Doppler US, CT, and MRI. Material and Methods: Abdominal CT and MRI with and without contrast agents and color Doppler US were performed on seven patients with hepatic alveolar Echinococcosis. The lesions were evaluated for location, features of echogenicity, intensity and density, calcification, and vascular, hilar, and perihepatic involvement. The diagnosis was confirmed histopathologically in all patients. Results: Six patients had solitary lesions, and one displayed multiple lesions. The lesions were generally seen as heterogeneous and hyper- or hypoechoic when imaged with color Doppler US, hypodense with CT, and hypointense with MRI, in comparison with the liver parenchyma. Calcification, central necrosis, and small peripheral cysts were observed in six, seven, and four patients, respectively. Vascular flow or contrast enhancement was not observed in any of the cases. A look at the respective advantages of each method reveals that calcification was best rendered visible via CT, small peripheral cysts with T2-weighted MRI, central necrosis with CT and MRI, and perihepatic invasion with multiplanar MRI. Vascular involvement was revealed by all methods. Conclusion: Color Doppler US, CT, and MR imaging function extremely well as complementary methods in the diagnosis of HAE. Color Doppler US should be performed in these patients owing to its ability to efficiently detect the disease. Knowledge of imaging characteristics makes it possible to radiologically ascertain an early diagnosis

  20. Color doppler findings of gastric varices compared with findings on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Suga, Toshihiro [Sapporo Kosei General Hospital (Japan)

    2002-08-01

    The aim of this study was to evaluate the hemodynamics of gastric varices. We evaluated the detection rates of gastric varices, inflowing vessels to gastric varices, and outflowing vessels from gastric varices in 24 patients with gastric varices, using color Doppler sonography, and compared these findings with computed tomography findings. Eighteen patients had F2-type varices and 6 had F3-type, classified according to the Japanese Research Society for Portal Hypertension. Fourteen patients had fundal varices, and 10 had cardiac and fundal varices. The detection rates of collateral veins using color Doppler sonography were as follows: gastric varices were detected in all 24 patients (100%); inflowing vessels, in 21 of the 24 patients (87.5%); and outflowing vessels, in 18 of the 24 patients (75.0%). The detection rates of collateral veins, using computed tomography, were: gastric varices were detected in all 24 patients (100%); inflowing vessels, in all 24 patients (100%); and outflowing vessles, in 21 of the 24 patients (87.5%). The color Doppler findings agreed perfectly with the computed tomography findings in 13 of the 24 patients (54.2%). Although color Doppler sonography is a useful, noninvasive modality for evaluating the hemodynamics of gastric varices, it falls short in visualizing the detailed hemodynamics of the inflowing and outflowing vessels of gastric varices in half of the patients when compared with computed tomography. (author)

  1. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2011-01-01

    hypertrophy, effusion) and by color Doppler (synovial hyperemia) before and 4 weeks after US-guided steroid injection. Results US detected 121 compartments with active disease (joints, tendon sheaths and 1 ganglion cyst). Multiple compartments were involved in 80% of the ankle regions. The talo-crural joint...

  2. Doppler color flow mapping of peripheral vessels: Comparison of angiodynography with conventional duplex US

    International Nuclear Information System (INIS)

    Merritt, C.R.B.; Bluth, E.I.; Sullivan, M.A.

    1986-01-01

    A new Doppler color flow imager was compared to duplex US in the evaluation of carotid and peripheral vessels in 50 patients. A 7.5-MHz transducer permitted simultaneous high-resolution real-time imaging of Doppler flow and tissue. The system was found to have excellent image quality and Doppler sensitivity. Flow characteristics and velocity measurements obtained with this system correlated well with those obtained using the duplex scanner and were obtained more quickly than with the conventional system, allowing more complete assessment of flow characteristics. Color Doppler flow imaging appears to be an extremely promising method for the rapid and effective evaluation of peripheral vascular flow

  3. Prenatal color Doppler ultrasonographic diagnosis of fetal tetralogy of Fallot

    International Nuclear Information System (INIS)

    Tan Buqiao

    2009-01-01

    Objective: To investigate the sonographic findings of tetralogy of Fallot in fetuses. Methods: The data of color Doppler ultrasonography and follow-up results of 5 fetal tetralogy of Fallot were analyzed retrospectively, and their abnormal ultrasound imaging characteristic were summarized. Results: Two cases were proved tetralogy of Fallot by autopsy, and three cases were confirmed to be tetralogy of Fallot by echocardiography after birth. The image features were the main aorta situated above the ventricular septal defect, pulmonary stenosis, no obvious thickening of the right wall. Conclusion: Fetal tetralogy of Fallot have characteristic ultrasound images, prenatal color Doppler ultrasonographic can diagnoses fetal tetralogy of Fallot correctly and has important clinical value. (authors)

  4. Study of retrobulbar hemodynamics in diabetes via color doppler ultrasound

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2014-09-01

    Full Text Available AIM: To explore the changes of retrobulbar hemodynamics in diabetes via color doppler ultrasound. METHODS: Totally 80 patients(160 eyeswith eye diseases in type 2 diabetes from June 2010 to May 2013 in our hospital were enrolled as research group. By fundus photography and direct ophthalmoscopy, patients were assigned to diabetes without retinopathy group(DNR subgroup, non-proliferative diabetic retinopathy group(NPDR subgroupand proliferative diabetic retinopathy group(PDR subgroup. Of 60 healthy patients(120 eyesover the same period were chosen as control group. The doppler parameters of central retinal artery(CRA, posterior ciliary artery(PCAand ophthalmic artery(OAwere measured.RESULTS: There were significant differences on circulatory parameters of CRA, PCA and OA between both groups(PPPCONCLUSION: The monitoring of retinal blood flow and analysis of blood spectrum morphology via color doppler ultrasound can effectively evaluate the degree of diabetic retinopathy lesions, especially before DR vascular disease. Early detection can reveal the hemodynamic change pattern of DR, facilitating the prevention of diabetic eye complications and improvement of the quality of life.

  5. Color doppler energy (CDE) : initial ten-months experience

    International Nuclear Information System (INIS)

    Ro, Young Jin; Son, Hyun Ju; Lee, Suck Hong; Kim, Byung Soo; Han, Kook Sang; Nam, SAng Hwa; Lee, Keum Seob; Shin Se Kwon

    1996-01-01

    Color Doppler imaging(CDI) has shortcomings, including random noise, aliasing, and angle dependence. To overcome these, a method using CD US, termed power doppler or Color Doppler Energy(CDE), has recently been introduced. The purpose of this study was to show the clinical usefulness of CDE. We retrospectively analyzed the CDI and CDE of 61 cases(20 renal pseudotumors, 8 musculoskeletal inflammations, 17 epididymitis or epididymo-orchitis, 3 varicoceles, 1 normal testis, 1 hepatocellualr carcinoma, 7 renal cell carcinoma, 1 renal angiomyolipoma, and 3 splenic varices). CDI and CDE scans were obtained at the same region with constant scan plane. The color gain was increased until noise first became perceptible, and scans were always obtained in such a way that the maximum amount of vascularity was shown. Thereafter, the vascularity, vascular displacement, and the vascular relationship between CDI and CDE were compared. In 17 of 20 cases of pseudotumor in the kidney, normal vascularity was identified in CDI and CDE, but was more cleary visible in CDE. In three cases, there was no visible vascularity in CDI, but normal vascularity in CDE. In eight cases of musculoskeletal inflammation and 17 cases of epididymitis with or without orchitis, the vascularity was increased due to hyperemia, which was more prominently seen in CDE than in CDI. In three varicoceles, CDE appeared to be better in demonstrating low velocity flow. In one patient who was suspected of having acute testicular torsion, CDE was helpful in excluding this suspicion. In one case of hepatocellualr carcinoma, seven cases of renal cell carcinoma, one case of renal angiomyolipoma, and three cases of splenic varices, CDE was better than CDI in showing the vascularity, vascular relationship, and vascular displacement

  6. Analysis on correlation between overall classification on color doppler ultrasound and clinical stages of atherosclerosis obliterans

    International Nuclear Information System (INIS)

    Zhang Dongmei; Liu Meihan; Shi Weidong; Chen Enqi; Li Xinying; Lin Yu

    2010-01-01

    Objective: To investigate the correlation and the clinical significance between the overall classification on color Doppler ultrasound and the clinical stages of atherosclerosis obliterans (ASO), and evaluate the extent of arterial lesions comprehensively. Methods: 125 patients of ASO, who were divided into three groups of mild, moderate and severe with Color Doppler ultrasound according to differences of occlusion, quantity, degree of stenosis and collateral number, were analyzed with clinical stages, then their associations were studied with Spearman rank analysis. Results: The clinical manifestations of ASO patients who were divided into three groups of mild, moderate and severe according to overall classification on color Doppler ultrasound were respectively gradually serious, which had positive correlations with the stages of I, II and III according to clinical stages. Spearman rank analysis showed that the correlation coefficients (rs)was 0.797 2 between two groups (P<0.01), there was good consistency between the overall classification on color Doppler ultrasound and the clinical stagesof ASO. Conclusion: The overall classification of ASO on color Doppler ultrasound has considered impact of many other factors on the clinical symptoms,such as the level of the local narrow, narrow scope, segments of occlusion and collateral arteries, which divides the lesions more objectively, shows good consistency with the clinical stages. (authors)

  7. Diagnostic agreement between panoramic radiographs and color doppler images of carotid atheroma

    Directory of Open Access Journals (Sweden)

    Claudia Maria Romano-Sousa

    2009-02-01

    Full Text Available The aim of this study was to investigate the agreement between diagnoses of calcified atheroma seen on panoramic radiographs and color Doppler images. Our interest stems from the fact that panoramic images can show the presence of atheroma regardless of the level of obstruction detected by color Doppler images. Panoramic and color Doppler images of 16 patients obtained from the archives of the Health Department of the city of Valença, RJ, Brazil, were analyzed in this study. Both sides of each patient were observed on the images, with a total of 32 analyzed cervical regions. The level of agreement between diagnoses was analyzed using the Kappa statistics. There was a high level of agreement, with a Kappa value of 0.78. In conclusion, panoramic radiographs can help detecting calcifications in the cervical region of patients susceptible to vascular diseases predisposing to myocardial infarction and cerebrovascular accidents. If properly trained and informed, dentists can refer their patients to a physician for a cardiovascular evaluation in order to receive proper and timely medical treatment.

  8. Power and color Doppler ultrasound settings for inflammatory flow: impact on scoring of disease activity in patients with rheumatoid arthritis.

    Science.gov (United States)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin; Ellegaard, Karen; D'Agostino, Maria Antonietta; Iagnocco, Annamaria; Naredo, Esperanza; Balint, Peter; Wakefield, Richard J; Torp-Pedersen, Arendse; Terslev, Lene

    2015-02-01

    To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. Six different types of ultrasound machines were used. On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. Power Doppler was more sensitive on half of the machines, whereas color Doppler was more sensitive on the other half, using both factory settings and study settings. There was an average increase in Doppler sensitivity, despite modality, of 78% when study settings were applied. Over the 6 machines, 2 Doppler modalities, and 2 settings, the grades for each of 7 of the patients varied between 0 and 3, while the grades for each of the other 4 patients varied between 0 and 2. The effect of using different machines, Doppler modalities, and settings has a considerable influence on the quantification of inflammation by ultrasound in RA patients, and this must be taken into account in multicenter studies. Copyright © 2015 by the American College of Rheumatology.

  9. Studi Penentuan Kecepatan Aliran Darah dan Frekuensi Terimaan Pasien Atherosclerosis Menggunakan USG Color Doppler

    OpenAIRE

    Mulyani, Emba

    2014-01-01

    Jurnal Fisika Medik Studi Penentuan Kecepatan Aliran Darah dan Frekuensi Terimaan Pasien Atherosclerosis Menggunakan USG Color Doppler Mulyani H211 08 507 Pembimbing Utama Sri Dewi Astuty Ilyas,Ssi, Msi Nip.19750513 199903 2 001 Pembimbing Pertama Dahlang Tahir, Msi, Ph.D Nip.19750907 200003 1 001 ABSTRACT Research about Study of determination blood speed of current and freq uency give patient atherosclero sis uses plane USG Color Doppler had be...

  10. Vascular response to ischemia in the feet of falanga torture victims and normal controls--color and spectral Doppler findings

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Amris, Kirstine; Holm, Christian Cato

    2009-01-01

    to controls. On color Doppler this would be seen as less color after ischemia and on spectral Doppler as elevated resistive index (RI). METHODS: Ten male torture victims from the Middle East and nine age, sex and ethnically matched controls underwent Doppler examination of the abductor hallucis and flexor...... digitorum brevis muscles before and after two minutes ischemia induced with a pressure cuff over the malleoli. The color Doppler findings were quantified with the color fraction (CF) before and after ischemia. On spectral Doppler the resistive index was measured once before and three consecutive times after....... However, the trend in RI still supports the hypothesis. The negative findings may be due to inadequate design where the CF and RI were measured in one setting, perhaps resulting in both methods being applied imperfectly. The response to ischemia seems short-lived and we suggest that the Doppler methods...

  11. Color M-mode and pulsed wave tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 month...

  12. Diagnosis of Cervical Abortion by TransvaginaI Color Doppler Sonography : A Case Report

    International Nuclear Information System (INIS)

    Lee, Eun Ju; Ryu, Hee Sug; Ji, Hoon; Suh, Jung Ho

    1995-01-01

    Cervical abortion is a spontaneous abortion of an intrauterine pregnancy into the cervical canal where the abortus is retained by a closed external os, causing distension of the cervical canal. Cervical abortion should be distinguished from the cervical pregnancy. We present a case of cervical abortion diagnosed preoperatively by transvaginal sonography and color doppler imaging, and treated by dilatation and curettage. Charateristic transvaginal sonographic findings and identification of subtrophoblastic blood flow by color doppler imaging could allow differentiation of the cevical aborition from the cervical pregnancy

  13. Clinical study of color Doppler sonography in Graves' disease blood flow changes after thyroid arteries embolization

    International Nuclear Information System (INIS)

    Zhuang Wenquan; Li Weiduo; Yang Jianyong; Chen Wei; Huang Yonghui; Guo Wenbo; Li Jiaping

    2003-01-01

    Objective: To study the color doppler image characteristics of thyroid arteries pre- and post-interventional procedure and to assess the clinical efficacy in Gnaves' disease. Methods: 11 from 31 patients diagnosed as Graves' disease undertaken thyroid arteries embolization, were analyzed. Color Doppler sonography was applied to monitor the pre-and post- procedure thyroid size and diameters of thyroid arteries. Power Doppler was used to detect the Vmax, Vmin, RI and blood flow. Results: After thyroid arteries embolization, the size and vascularity of thyroids were reduced. The thyroid arteries showed shrinkage and stoppage blood flow at the embolized site. The changes of RI, blood parameters of Vmax, Vmin and diameters of the thyroid arteries pre- and post-procedure turned out to be statistically significant for clinical restriction. Conclusion: The color Doppler sonography plays an important role for preoperative diagnosis and predicting the prognosis

  14. Reducción de color con cloruro de magnesio en soluciones con colorantes comerciales

    Directory of Open Access Journals (Sweden)

    Mercedes Lucero Chávez

    2017-01-01

    Full Text Available Se experimentó con diferentes concentraciones de cloruro de magnesio (MgCl2 como coagulante para reducir el color en soluciones con colorantes comerciales: negro, azul y café. Los parámetros analizados fueron pH, color, demanda química de oxígeno ( dqo y sólidos suspendidos totales (sst de acuerdo con las Normas Mexicanas. Como prueba complementaria se agregó carbón activado a las muestras para reducir el color residual después de la coagulación-floculación. La reducción de los valores de color y dqo fue mayor cuando se adicionó más cantidad de MgCl2 (1.8 g/L. Los porcentajes de reducción fueron ≥90% para el color y >50% para la dqo. Los sst aumentaron con la adición de MgCl2. El carbón activado eliminó el color residual.

  15. Características cinefluoroscópicas de ocho modelos de prótesis mecánicas bivalvas implantadas en la República Argentina: su valor complementario al ecocardiograma Doppler color

    Directory of Open Access Journals (Sweden)

    Tomás F. Cianciulli

    2008-01-01

    Full Text Available Los diferentes modelos de prótesis valvulares mecánicas son numerosos y su reconocimiento por ecocardiografía es difícil. La cinefluoroscopia (CF puede complementar su identificación y su evaluación.Objetivos1 Describir las características cinefluoroscópicas de cada prótesis para su identificación. 2 Evaluar su función mediante la comparación de los gradientes del eco-Doppler con el ángulo de apertura de los discos basculantes en la CF. 3 Reconocer la capacidad de la CF para diferenciar prótesis normales de prótesis disfuncionantes.Material y métodosSe evaluaron prospectivamente 219 prótesis implantadas en 191 pacientes. Se excluyeron 14 prótesis debido a la coexistencia de disfunción sistólica ventricular izquierda grave. El análisis se realizó sobre 205 prótesis (142 aórticas y 63 mitrales.ResultadosA través de las características del anillo y de los discos, mediante la CF se logró identificar el modelo de la prótesis en el 100% de las válvulas. La movilidad de los discos permitió diferenciar prótesis normales de disfuncionantes (ángulo de apertura 79,3° ± 5,4° versus 58,7° ± 15°, respectivamente. En la CF no se pudieron perfilar los discos y/o el anillo en el 3,9% de las prótesis aórticas y en el 19,2% de las mitrales.De las 142 prótesis aórticas, el eco-Doppler identificó 112 normales y 30 disfuncionantes y de las 63 prótesis mitrales identificó 52 normales y 11 disfuncionantes.Al correlacionar ambos métodos, la sensibilidad, la especificidad, el valor predictivo positivo y el valor predictivo negativo de la fluoroscopia para diferenciar prótesis normales de disfuncionantes fueron del 71%, 93%, 67% y 94%, respectivamente.Conclusiones1 Cada modelo de prótesis valvular tiene características cinefluoroscópicas que permiten su identificación. 2 La cinefluoroscopia evalúa el funcionamiento de las prótesis mecánicas y distingue una normal de una disfuncionante. 3 Cuando hay gradientes altos y

  16. High resolution compression elastography and color doppler sonography in characterization of breast fibroadenoma.

    Science.gov (United States)

    Rjosk-Dendorfer, D; Reu, S; Deak, Z; Hetterich, H; Kolben, T; Reiser, M; Clevert, D A

    2014-01-01

    To evaluate the use of color Doppler sonography and free hand sonoelastography in the assessment of breast fibroadenomas according to their size and shape. From December 2012 to March 2013 women with 16 solid breast masses, classified as BI-RADS category 3 or 4 were examined with B-mode ultrasound, sonoelastography and color Doppler sonography. Lesions were subdivided according to their shape in round, ovoid or macrolobulated and according to their size (fibroadenomas in B-mode sonography could be shown (p = 0.91) and also comparison of Tsukuba-scores and size of masses revealed no significant differences (p = 1.0). Sizes of fibroadenomas ≥2 cm were significantly associated with an increased vascularization of the lesions (p = 0.04) and a macrolobulated appearance in B-mode sonography (p = 0.04). The combination of color Doppler sonography and sonoelastography in addition to B-mode sonography leads to an increased accuracy in distinguishing benign from malignant breast masses and to an improvement in characterization of fibroadenomas independent of their shape or size.

  17. Role of color Doppler in differentiation of Graves' disease and thyroiditis in thyrotoxicosis

    Science.gov (United States)

    Donkol, Ragab Hani; Nada, Aml Mohamed; Boughattas, Sami

    2013-01-01

    AIM: To evaluate the role of thyroid blood flow assessment by color-flow Doppler ultrasonography in the differential diagnosis of thyrotoxicosis and compare it to technetium pertechnetate thyroid scanning. METHODS: Twenty-six patients with thyrotoxicosis were included in the study. Clinical history was taken and physical examination and thyroid function tests were performed for all patients. Thyroid autoantibodies were measured. The thyroid glands of all patients were evaluated by gray scale ultrasonography for size, shape and echotexture. Color-flow Doppler ultrasonography of the thyroid tissue was performed and spectral flow analysis of both inferior thyroid arteries was assessed. Technetium99 pertechnetate scanning of the thyroid gland was done for all patients. According to thyroid scintigraphy, the patients were divided into two groups: 18 cases with Graves’ disease and 8 cases with Hashimoto’s thyroiditis. All patients had suppressed thyrotropin. The diagnosis of Graves’ disease and Hashimoto’s thyroiditis was supported by the clinical picture and follow up of patients. RESULTS: Peak systolic velocities of the inferior thyroid arteries were significantly higher in patients with Graves’ disease than in patients with thyroiditis (P = 0.004 in the right inferior thyroid artery and P = 0.001 in left inferior thyroid artery). Color-flow Doppler ultrasonography parameters demonstrated a sensitivity of 88.9% and a specificity of 87.5% in the differential diagnosis of thyrotoxicosis. CONCLUSION: Color Doppler flow of the inferior thyroid artery can be used in the differential diagnosis of thyrotoxicosis, especially when there is a contraindication of thyroid scintigraphy by radioactive material in some patients. PMID:23671754

  18. Spectral color Doppler in the diagnosis and follow-up of Graves' disease

    International Nuclear Information System (INIS)

    Sponza, Massimo; Bertolotto, Michele; Ricci, Claudio; Fabris, Bruno; Armini, Lorenzo

    1997-01-01

    Hyperthyroidism in Graves' disease is caused by the presence of circulating autoantibodies to the THS receptors on the thyroid cells. Thyroid-suppression therapy prevents hormone production directly, without affecting the pathogenetic process. They performed color Doppler US of the thyroid gland and pulsed Doppler analysis of thyroid artery flow in 21 patients with Graves' disease before and during medical treatment. US results were compared with those of a control group of 40 healthy subjects and correlated with the values of thyroid hormones, TSH and thyroid microsomal and thyroglobulin antibodies. The thyroid gland was hypo vascularized in the control group. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity of PSV 20 ± 4 cm/s, diastolic velocity of 8 ± 1 cm/s, and resistive index of 0.60 ± 0.04. The thyroid gland of Graves' disease patients was hyper vascularized. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity (PSV = 51 ± 12 cm/s), end diastolic velocity (VD = 15 ± 4 cm/s) and resistive index (RI = 0.71 ± 0.04) significantly higher than in normal subjects (p < 0.001). Circulating thyroid hormones and flow parameters normalized after 6-8 months of medical therapy (PSV = 20 ± 6 cm/s, VD = 9 ± 3 cm(s, RI = 0.58 ± 0.07). The color Doppler patterns normalized only in a patient with normal TSH and antibodies. Sampling of the thyroid arteries proved more repeatable than sampling of parenchymal vessels

  19. Role of color Doppler ultrasound in the diagnosis of nonpalpable ...

    African Journals Online (AJOL)

    excluded from the study. Color Doppler was performed in all cases, followed by laparoscopy. Further, findings on laparoscopy were compared with those of CDUS. A 95% confidence interval for the sensitivity of CDUS was estimated considering a positive result on CDUS as the binomial variable. Results. Out of 25 patients, ...

  20. Color Doppler Echocardiographic Assessment of Valvular Regurgitation in Normal Infants

    Directory of Open Access Journals (Sweden)

    Shu-Ting Lee

    2010-01-01

    Conclusion: The prevalence of inaudible valvular regurgitation is high in infants with structurally normal hearts. Multiple-valve involvement with regurgitation is not uncommon. Mild severity and low velocity on color Doppler, and the structural information provided by 2D imaging strongly suggest that these regurgitant flows are physiologically normal in infancy.

  1. 99m-Tc DMSA scintigraphy and color/power doppler sonography for children pyelonephritis diagnosis and follow-up

    International Nuclear Information System (INIS)

    Hitzel, A.; Manrique, A.; Gardin, I.; Vera, P.; Hitzel, A.; Dacher, J.N.; Manrique, A.; Menard, J.F.; Gardin, I.; Vera, P.; Dacher, J.N.; Liard, A.; Menard, J.F.

    2004-01-01

    Early diagnosis of acute pyelonephritis is essential to avoid scarring development. This study was performed to evaluate capabilities of color/doppler sonography to detect pyelonephritis and to predict scarring when compared with 99m Tc-DMSA scintigraphy. Fifty-seven children were evaluated during pyelonephritis: biology (CRP, creatinine, blood formula), color/power doppler sonography and 99m Tc-DMSA scintigraphy (DMSA1). 7 ± 2 months later, follow-up consisted in biological tests and a 99m 'Tc-DMSA scintigraphy (DMSA2). During pyelonephritis, body temperature, CRP value and neutrophil counts were significantly higher in patients with an abnormal DMSA1 but not in patients with abnormal doppler sonography. When compared with DMSA1, doppler sonography sensitivity and specificity were 80% and 81% respectively. DMSA1 and doppler sonography were concordant in 86% of children with a pyelonephritis. At follow-up, all clinical et biological parameters were normalized. DMSA2 was abnormal in 51% of children. When compared with DMSA2, positive and negative predictive values for scarring of doppler sonography were 57% and 75% respectively. DMSA 1, positive and negative predictive values for scarring were 62% and 100%. In conclusion, color/power doppler sonography is a reliable tool for pyelonephritis diagnosis, but its predictive value for scarring is poor. Negative predictive value of DMSA scintigraphy is excellent. (author)

  2. [Current role of color Doppler ultrasound in acute renal failure].

    Science.gov (United States)

    Bertolotto, M; Quaia, E; Rimondini, A; Lubin, E; Pozzi Mucelli, R

    2001-01-01

    Acute Renal Failure (ARF) is characterized by a rapid decline of the glomerular filtration rate, due to hypotension (prerenal ARF), obstruction of the urinary tract (post-renal ARF) or renal parenchymal disease (renal ARF). The differential diagnosis among different causes of ARF is based on anamnesis, clinical symptoms and laboratory data. Usually ultrasound (US) is the only imaging examination performed in these patients, because it is safe and readily available. In patients with ARF gray scale US is usually performed to rule out obstruction since it is highly sensitive to recognize hydronephrosis. Patients with renal ARF have no specific changes in renal morphology. The size of the kidneys is usually normal or increased, with smooth margins. Detection of small kidneys suggests underlying chronic renal pathology and worse prognosis. Echogenicity and parenchymal thickness are usually normal, but in some cases there are hyperechogenic kidneys, increased parenchymal thickness and increased cortico-medullary differentiation. Evaluation of renal vasculature with pulsed Doppler US is useful in the differential diagnosis between prerenal ARF and acute tubular necrosis (ATN), and in the diagnosis of renal obstruction. Latest generation US apparatus allow color Doppler and power Doppler evaluation of renal vasculature up to the interlobular vessels. A significant, but non specific, reduction in renal perfusion is usually appreciable in the patients with ARF. There are renal pathologic conditions presenting with ARF in which color Doppler US provides more specific morphologic and functional information. In particular, color Doppler US often provides direct or indirect signs which can lead to the right diagnosis in old patients with chronic renal insufficiency complicated with ARF, in patients with acute pyelonephritis, hepatic disease, vasculitis, thrombotic microangiopathies, and in patients with acute thrombosis of the renal artery and vein. Contrast enhanced US is

  3. Color/power Doppler transrectal US in prostate cancer: Correlation with Gleason score

    International Nuclear Information System (INIS)

    Kim, Hyo Cheol; Kim, Seung Hyup; Moon, Min Hoan; Park, Byung Kwan; Kim, Keon Ha; Choi, Hyuck Jae; Yoon, Chang Jin

    2002-01-01

    To evaluate the relationship between hypervascularity on color/power Doppler transrectal ultrasonography and the Gleason score of corresponding biopsied specimen in patients with prostatic cancer. From July 1998 to March 2002, one hundred fifty seven patients with pathologically proven prostate cancer at this institution were included, and all of them underwent transrectal ultrasonographic examination. Initially, ultrasonographic findings and pathologic data of 129 patients were retrospectively reviewed and excluded 28 patients whose sonographic images were either unavailable or inconclusive. The presence of hypoechoic lesion on transrectal sonography and hypervascularity on color/power Doppler sonography in the peripheral zone of the prostate was first evaluated, and these sonographic findings and Gleason score of the corresponding biopsied specimen were then compared. Statistical analysis was done by Student t-test using SPSS package. Among one hundred twenty nine patients, ninety four patients had a hypoechoic lesion on gray scale sonography while sixty one showed a hypervascular lesion on color/power Doppler sonography. Fifty seven of 61 patients (93.4%) had hypoechoic lesion on gray scale sonography. The mean Gleason score of patients with hypervascular lesion was 7.9 ± 0.98 whereas that of the patients without hypervascular lesion, 6.9 ± 1.22, showing a statistically significant difference (p<0.01). Prostate cancer with hypervascularity on transrectal sonography appears to have a higher Gleason score on pathologic examination than that without hypervascularity.

  4. Bio-inspired color sketch for eco-friendly printing

    Science.gov (United States)

    Safonov, Ilia V.; Tolstaya, Ekaterina V.; Rychagov, Michael N.; Lee, Hokeun; Kim, Sang Ho; Choi, Donchul

    2012-01-01

    Saving of toner/ink consumption is an important task in modern printing devices. It has a positive ecological and social impact. We propose technique for converting print-job pictures to a recognizable and pleasant color sketches. Drawing a "pencil sketch" from a photo relates to a special area in image processing and computer graphics - non-photorealistic rendering. We describe a new approach for automatic sketch generation which allows to create well-recognizable sketches and to preserve partly colors of the initial picture. Our sketches contain significantly less color dots then initial images and this helps to save toner/ink. Our bio-inspired approach is based on sophisticated edge detection technique for a mask creation and multiplication of source image with increased contrast by this mask. To construct the mask we use DoG edge detection, which is a result of blending of initial image with its blurred copy through the alpha-channel, which is created from Saliency Map according to Pre-attentive Human Vision model. Measurement of percentage of saved toner and user study proves effectiveness of proposed technique for toner saving in eco-friendly printing mode.

  5. Acute scrotal pathology in Schonlein-Henoch purpura: management by color Doppler ultrasound. A case report

    International Nuclear Information System (INIS)

    Jornet, J.; Cervera, J.; Marco, S.F.; Gonzalez, M.

    1998-01-01

    Schonlein-Henoch purpura is the most common form of purpura in children. It can affect a number of organs, but scrotal involvement is rare. We present a case of scrotal hemorrhage and epidymo-orchitis, diagnosed by color Doppler ultrasound, in which conservative treatment was employed. The differential diagnosis involves testicular torsion, which is also, although less frequently, associated with Schonlein-Henoch purpura. color Doppler ultrasound results in the correct diagnosis, ruling out testicular torsion and avoiding surgical exploration of the testicles. (Author) 8 refs

  6. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Giuseppe; Attard, Marco; Caronia, Aurelio; Lagalla, Roberto

    2000-10-01

    Purpose: The aim of the study is to find out whether the measurement of peak systolic velocity in the inferior thyroid artery (ITA) is a valuable parameter to differentiate autoimmune thyroid diseases (hyper-, normo- or hypofunctional) and to evaluate the efficacy of medical treatment. Material and methods: The ITA of 31 patients (eight with Graves' disease, 23 with subclinical hypothyroidism) was examined with color Doppler and pulsed Doppler. The final diagnosis was obtained by citology and by hormonal and antibodies assays. The patients were monitorized by ultrasound for a period of 8 months. Results: In all the patients with Graves' disease the peak systolic velocity was always over 150 cm/s, while in other autoimmune thyroiditis the peak systolic velocity was within the normal range, and never exceeding 65 cm/s. In the first group, the measurement taken in the ITA showed also the efficacy of the pharmacological treatment earlier and more reliably than the color Doppler pattern obtained in the parenchyma. Conclusions: The color Doppler measurement of the ITA seems to be a promising technique with low-cost and easy approach. In our experience, the color Doppler of the ITA could have a clinical role in the differential diagnosis of diffuse thyroid diseases and in the follow-up of the Graves' disease during medical treatment.

  7. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases

    International Nuclear Information System (INIS)

    Caruso, Giuseppe; Attard, Marco; Caronia, Aurelio; Lagalla, Roberto

    2000-01-01

    Purpose: The aim of the study is to find out whether the measurement of peak systolic velocity in the inferior thyroid artery (ITA) is a valuable parameter to differentiate autoimmune thyroid diseases (hyper-, normo- or hypofunctional) and to evaluate the efficacy of medical treatment. Material and methods: The ITA of 31 patients (eight with Graves' disease, 23 with subclinical hypothyroidism) was examined with color Doppler and pulsed Doppler. The final diagnosis was obtained by citology and by hormonal and antibodies assays. The patients were monitorized by ultrasound for a period of 8 months. Results: In all the patients with Graves' disease the peak systolic velocity was always over 150 cm/s, while in other autoimmune thyroiditis the peak systolic velocity was within the normal range, and never exceeding 65 cm/s. In the first group, the measurement taken in the ITA showed also the efficacy of the pharmacological treatment earlier and more reliably than the color Doppler pattern obtained in the parenchyma. Conclusions: The color Doppler measurement of the ITA seems to be a promising technique with low-cost and easy approach. In our experience, the color Doppler of the ITA could have a clinical role in the differential diagnosis of diffuse thyroid diseases and in the follow-up of the Graves' disease during medical treatment

  8. Evaluation of diagnosis of small breast cancer with high frequency and color doppler ultrasound

    International Nuclear Information System (INIS)

    Xia Guobing; Hu Chunhong; Jing Qiulong

    2008-01-01

    Objective: To probe the features of high frequency ultrasonography (HFU) and color Doppler ultrasound (CDU) in the case of small breast cancers in order to evaluate the diagnostic value for small breast cancer with CDU. Methods: The features of HFU and CDU were respective analyzed in 67 small breast masses, the biggest diameter of which was under 2cm identified with pathology. Results Partially characteristic changes of small breast cancers were displayed, and micro-calcification within the mass was an important characteristic, in addition, the Resistant Index (RI) ≥ 0.70 on Pulsed Doppler (PD) and the grade of blood flow on Color Doppler Flow Imaging (CDFI)≥T2 implied much more positive malignancy prediction. Conclusion: HFU integrated with CDU can be used for the early and accurate diagnosis of the small breast cancer. (authors)

  9. A feasability study of color flow doppler vectorization for automated blood flow monitoring.

    Science.gov (United States)

    Schorer, R; Badoual, A; Bastide, B; Vandebrouck, A; Licker, M; Sage, D

    2017-12-01

    An ongoing issue in vascular medicine is the measure of the blood flow. Catheterization remains the gold standard measurement method, although non-invasive techniques are an area of intense research. We hereby present a computational method for real-time measurement of the blood flow from color flow Doppler data, with a focus on simplicity and monitoring instead of diagnostics. We then analyze the performance of a proof-of-principle software implementation. We imagined a geometrical model geared towards blood flow computation from a color flow Doppler signal, and we developed a software implementation requiring only a standard diagnostic ultrasound device. Detection performance was evaluated by computing flow and its determinants (flow speed, vessel area, and ultrasound beam angle of incidence) on purposely designed synthetic and phantom-based arterial flow simulations. Flow was appropriately detected in all cases. Errors on synthetic images ranged from nonexistent to substantial depending on experimental conditions. Mean errors on measurements from our phantom flow simulation ranged from 1.2 to 40.2% for angle estimation, and from 3.2 to 25.3% for real-time flow estimation. This study is a proof of concept showing that accurate measurement can be done from automated color flow Doppler signal extraction, providing the industry the opportunity for further optimization using raw ultrasound data.

  10. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    International Nuclear Information System (INIS)

    Ayaz, Tunahan; Akansel, Gur.; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-01-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia

  11. A rare case of OEIS complex –newer approach to diagnosis of exstrophy bladder by color doppler and its differentiation from simple omphalocele

    Directory of Open Access Journals (Sweden)

    Kavita Aneja

    2017-01-01

    Full Text Available The objective of this article is to present a new approach to diagnose and differentiate similar ventral masses by color Doppler. Two cases of ventral masses, a rare case of OEIS complex (Omphalocele-exstrophy-imperforate anus-spinal defects with unusual presentation of exstrophy bladder and another of simple omphalocele, were studied by color Doppler for diagnosis and differentiation between the nature of similar masses. Ventral mass with absent bladder, normal kidneys, and normal amniotic fluid index raised the suspicion of exstrophy bladder. Color Doppler depicting altered intrafetal course of umbilical arteries and umbilical arteries coursing along the sides of ventral mass substantiated the diagnosis. The spatial relation between umbilical artery and aorta (which has no mention in the current literature in sagittal view has been identified as an acute angle in a normal fetus and coined as “K angle” arbitrarily by the author. Color Doppler reveals altered (widened “K angle” in exstrophy bladder compared to normal fetuses. Other combined anomalies pointed to the diagnosis of OEIS complex. The second case of simple omphalocele depicts normal intrafetal course of umbilical arteries and normal acute umbilical artery–aorta angle (K angle on color Doppler. Color Doppler aids the early diagnosis of ventral defects. New method by umbilical artery-aorta angle (K angle assessment on color Doppler helps differentiate exstrophy bladder from omphalocele.

  12. Usefulness of color and pulsed Doppler's in the evaluation of surgical portosystemic shunts in pediatric patients; Utilidad del Doppler color y pulsado en la valoracion de los shunts portosistemicos quirurgicos en la edad pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Berrocal, T.; Prieto, C.; Cortes, P.; Rodriguez, R.; Pastor, I. [Hospital Universitario La Paz. Madrid (Spain)

    2003-07-01

    Portosystemic shunts are performed to relieve symptomatic portal hypertension symptomatic or removal pressure in hepatic vascularisation in patients with Budd-Chiari's syndrome. Most surgical portosystemic shunts can be suitably studied by means of ultrasound scan complemented by color and pulsed Dopplers, proved one understands the hemodynamics of the surgical procedures involved. This article demonstrates the usefulness and limitations of the ultrasound scan Duplex Doppler in the evaluation of portosystemic shunts performed on pediatric patients. Pulsed Doppler provides information regarding the nature and direction of blood flow. Color doppler is capable of directly revealing the shunt and, in most cases, permits the anastomosis to be located. The types of shunts that appear include proximal and distal spleno-renal, portocaval and mesocaval. Types of vascular connections are illustrated,s well as expected post-surgical blood flow direction in affected vessels. The ultrasound scanning technique is discussed, as well as the criteria for determining vascular permeability. Also highlighted are the advantages, limitations and diagnostic difficulties associated with the different forms of Doppler. (Author) 17 refs.

  13. Two-dimensional intraventricular flow mapping by digital processing conventional color-Doppler echocardiography images.

    Science.gov (United States)

    Garcia, Damien; Del Alamo, Juan C; Tanne, David; Yotti, Raquel; Cortina, Cristina; Bertrand, Eric; Antoranz, José Carlos; Perez-David, Esther; Rieu, Régis; Fernandez-Aviles, Francisco; Bermejo, Javier

    2010-10-01

    Doppler echocardiography remains the most extended clinical modality for the evaluation of left ventricular (LV) function. Current Doppler ultrasound methods, however, are limited to the representation of a single flow velocity component. We thus developed a novel technique to construct 2D time-resolved (2D+t) LV velocity fields from conventional transthoracic clinical acquisitions. Combining color-Doppler velocities with LV wall positions, the cross-beam blood velocities were calculated using the continuity equation under a planar flow assumption. To validate the algorithm, 2D Doppler flow mapping and laser particle image velocimetry (PIV) measurements were carried out in an atrio-ventricular duplicator. Phase-contrast magnetic resonance (MR) acquisitions were used to measure in vivo the error due to the 2D flow assumption and to potential scan-plane misalignment. Finally, the applicability of the Doppler technique was tested in the clinical setting. In vitro experiments demonstrated that the new method yields an accurate quantitative description of the main vortex that forms during the cardiac cycle (mean error for vortex radius, position and circulation). MR image analysis evidenced that the error due to the planar flow assumption is close to 15% and does not preclude the characterization of major vortex properties neither in the normal nor in the dilated LV. These results are yet to be confirmed by a head-to-head clinical validation study. Clinical Doppler studies showed that the method is readily applicable and that a single large anterograde vortex develops in the healthy ventricle while supplementary retrograde swirling structures may appear in the diseased heart. The proposed echocardiographic method based on the continuity equation is fast, clinically-compliant and does not require complex training. This technique will potentially enable investigators to study of additional quantitative aspects of intraventricular flow dynamics in the clinical setting by

  14. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    Energy Technology Data Exchange (ETDEWEB)

    Ayaz, Tunahan; Akansel, Gur. E-mail: gakansel@superonline.com; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-06-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia.

  15. Usefulness of color and pulsed Doppler's in the evaluation of surgical portosystemic shunts in pediatric patients

    International Nuclear Information System (INIS)

    Berrocal, T.; Prieto, C.; Cortes, P.; Rodriguez, R.; Pastor, I.

    2003-01-01

    Portosystemic shunts are performed to relieve symptomatic portal hypertension symptomatic or removal pressure in hepatic vascularisation in patients with Budd-Chiari's syndrome. Most surgical portosystemic shunts can be suitably studied by means of ultrasound scan complemented by color and pulsed Dopplers, proved one understands the hemodynamics of the surgical procedures involved. This article demonstrates the usefulness and limitations of the ultrasound scan Duplex Doppler in the evaluation of portosystemic shunts performed on pediatric patients. Pulsed Doppler provides information regarding the nature and direction of blood flow. Color doppler is capable of directly revealing the shunt and, in most cases, permits the anastomosis to be located. The types of shunts that appear include proximal and distal spleno-renal, portocaval and mesocaval. Types of vascular connections are illustrated,s well as expected post-surgical blood flow direction in affected vessels. The ultrasound scanning technique is discussed, as well as the criteria for determining vascular permeability. Also highlighted are the advantages, limitations and diagnostic difficulties associated with the different forms of Doppler. (Author) 17 refs

  16. Digital storage and analysis of color Doppler echocardiograms

    Science.gov (United States)

    Chandra, S.; Thomas, J. D.

    1997-01-01

    Color Doppler flow mapping has played an important role in clinical echocardiography. Most of the clinical work, however, has been primarily qualitative. Although qualitative information is very valuable, there is considerable quantitative information stored within the velocity map that has not been extensively exploited so far. Recently, many researchers have shown interest in using the encoded velocities to address the clinical problems such as quantification of valvular regurgitation, calculation of cardiac output, and characterization of ventricular filling. In this article, we review some basic physics and engineering aspects of color Doppler echocardiography, as well as drawbacks of trying to retrieve velocities from video tape data. Digital storage, which plays a critical role in performing quantitative analysis, is discussed in some detail with special attention to velocity encoding in DICOM 3.0 (medical image storage standard) and the use of digital compression. Lossy compression can considerably reduce file size with minimal loss of information (mostly redundant); this is critical for digital storage because of the enormous amount of data generated (a 10 minute study could require 18 Gigabytes of storage capacity). Lossy JPEG compression and its impact on quantitative analysis has been studied, showing that images compressed at 27:1 using the JPEG algorithm compares favorably with directly digitized video images, the current goldstandard. Some potential applications of these velocities in analyzing the proximal convergence zones, mitral inflow, and some areas of future development are also discussed in the article.

  17. Pulsed and Color Doppler Sonographic Findings of Penile Mondor' Disease

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hye Yeon; Chung, Dong Jin; Kim, Kum Won; Hwang, Cheol Mog [University of Konyang School of Medicine, Daejeon (Korea, Republic of)

    2008-04-15

    Penile Mondor's disease is a rare disease that's characterized by thrombosis in the dorsal vein of the penis. Doppler ultrasonography (US) clearly visualizes dorsal vein thrombosis and the associated hemodynamic alterations. Previous studies have demonstrated the typical color Doppler US findings of superficial dorsal vein thrombosis without the flow signals in this area, yet this is insufficient to understand the hemodynamics in penile Mondor's disease. We report here for the first time a cavernosal artery flow signal pattern in a penile Mondor's disease patient, in addition to its previously reported classic US findings. In conclusion, the Doppler US findings of thrombus without blood flow in the superficial dorsal vein and the low-flow, high resistance in the cavernosal artery may be suggestive of penile Mondor's disease.

  18. Cow's milk allergy: color Doppler ultrasound findings in infants with hematochezia.

    Science.gov (United States)

    Epifanio, Matias; Spolidoro, Jose Vicente; Missima, Nathalia Guarienti; Soder, Ricardo Bernardi; Garcia, Pedro Celiny Ramos; Baldisserotto, Matteo

    2013-01-01

    ultrasound (US) has been an important diagnostic tool to identify several causes of gastrointestinal bleeding. Infants with cow's milk allergy (CMA) may present hematochezia and the confirmation of the diagnosis can be difficult. The aim of this study is to describe grayscale and color Doppler ultrasound findings in patients with CMA. we retrospectively studied 13 infants with CMA. All infants presented severe hematochezia and abdominal pain. All underwent an US study with the diagnosis of allergic colitis. This diagnosis was based on clinical findings, recovery after infant or mother exclusion diets in the case of exclusive breastfeeding and positive oral challenge test. the mean age ranged from 1 to 6 months (mean=3.53). Seven out of 13 infants (53.8%) had grayscale and color Doppler sonographic repeated after exclusion diet. Twelve out of 13 (92,3%) showed abnormalities at US and CDUS at beginning. The positive findings suggesting colitis were thickened bowel walls and increased vascularity, especially in the descending and sigmoid colon. Colonoscopy and histopathological findings were compatible with allergic colitis. After a diet change the 13 infants recovered and their oral challenge tests were positive. Doppler US may be very useful in diagnosing secondary colitis, such as CMA, and to exclude several other abdominal diseases that can emulate this disease. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  19. Validation of color Doppler sonography for evaluating relative displacement between the flexor tendon and subsynovial connective tissue.

    Science.gov (United States)

    Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J

    2015-04-01

    A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.

  20. Comparative study of multi-slice spiral CT angiography and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity

    International Nuclear Information System (INIS)

    Li Wanjun; Lai Zhenhui; Cui Dong; Lin Xiupeng; Du Muxuan

    2010-01-01

    Objective: To compare the difference between multi-slice spiral CT angiography (MSCTA) and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity. Methods: Patients with arteriosclerosis occlusion were assessed by color doppler ultrasound, multi-slice spiral CT angiography and digital subtraction angiography (DSA). The image information of color doppler ultrasound and MSCTA were compared with that of DSA. Results: Color doppler ultrasound showed the anatomical shape and hemodynamics of the arteries of lower extremity. The sensitivity, specificity, and accuracy for diagnosis arteriosclerotic occlusive disease of lower extremity were 88.04%, 90.69% and 88.77% respectively. MSCTA showed the three dimensional structure of the arteries of lower extremity as well as the collateral arteries and the distal arterials. The sensitivity, specificity and accuracy of MSCTA were 97.69%, 96.90% and 97.66%, respectively. Conclusion: Multi-slice spiral CT angiography is an ideal imaging method for the diagnosis of arteriosclerotic occlusive disease of lower extremity. (authors)

  1. The Efficacy of Magnetic Resonance Imaging and Color Doppler Ultrasonography in Diagnosis of Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    Behrooz Davachi

    2014-12-01

    Full Text Available Background and aims. Although salivary gland tumors are not very common, early diagnosis and treatment is crucial because of their proximity to vital organs, and therefore, determining the efficacy of new imaging procedures becomes important. This study aimed to evaluate the efficacy of magnetic resonance imaging (MRI and color doppler ultrasonography parameters in the diagnosis and differentiation of benign and malignant salivary gland tumors. Materials and methods. In this cross-sectional study, color doppler ultrasonography and MRI were performed for 22 patients with salivary gland tumor. Demographic data as well as MRI, color doppler ultrasonography, and surgical parameters including tumor site, signal in MRI images, ultrasound echo, tumor border, lymphadenopathy, invasion, perfusion, vascular resistance index (RI, vascular pulse index (PI were analyzed using Chi-square test, Fisher’s exact test, and independent ttest. Results. The mean age of patients was 46.59±13.97 years (8 males and 14 females. Patients with malignant tumors were older (P < 0.01. The most common tumors were pleomorphic adenoma (36.4%, metastasis (36.4%, and mucoepidermoid carcinoma (9%. Nine tumors (40.9% were benign and 13 (59.1% were malignant. The overall accuracy of MRI and color doppler ultrasonography in determining tumor site was 100% and 95%, respectively. No significant difference observed between RI and PI and the diagnosis of tumor. Conclusion. Both MRI and ultrasonography have high accuracy in the localization of tumors. Well-identified border was a sign of benign tumors. Also, invasion to adjacent structures was a predictive factor for malignancy.

  2. Prevalência do refluxo na veia safena parva em varizes primárias não complicadas dos membros inferiores pelo eco-Doppler colorido Prevalence of short saphenous vein reflux in primary uncomplicated varicose veins by Doppler ultrasonography

    Directory of Open Access Journals (Sweden)

    Fabio Secchi

    2006-03-01

    Full Text Available OBJETIVO: Determinar a prevalência de refluxo venoso na veia safena parva em membros inferiores com varizes primárias não complicadas pelo eco-Doppler colorido. MÉTODO: No período de 18 meses, 1.953 pacientes foram submetidos ao eco-Doppler colorido de membros inferiores por doença venosa. Destes, 1.631 com varizes primárias não complicadas foram selecionados para esta análise, sendo que 1.383 eram do sexo feminino (84,79% e 248 (15,21% do sexo masculino. A média de idade dos pacientes foi de 42,89 (± 0,48 anos, variando de 13 a 85 anos. Dos 1.631 pacientes, 1.323 foram submetidos a exame bilateral e 308 a exame unilateral, totalizando 2.954 membros inferiores com varizes primárias não complicadas avaliados. Desse total, 1.461 eram membros inferiores direitos e 1.493, esquerdos. Todos os exames foram realizados seguindo o mesmo protocolo. RESULTADO: Dos 2.954 membros inferiores avaliados, 372 (12,59% apresentaram refluxo em veia safena parva. A prevalência nos homens foi de 14,08% e, nas mulheres, de 12,35%. O refluxo da safena parva foi maior no membro inferior esquerdo (13.13% do que no direito (12,05%. A prevalência do refluxo foi significativamente maior nos pacientes acima de 60 anos. CONCLUSÃO: O refluxo da veia safena parva é relativamente comum, e sua pesquisa deve ser sempre realizada em pacientes com varizes primárias de membros inferiores.OBJECTIVE: To determine the prevalence of small saphenous vein reflux (SSVR in patients with uncomplicated varicose veins, using color-flow Doppler ultrasonography. METHOD: Over an 18-month period, a total of 1,953 patients underwent color-flow Doppler ultrasonography for evaluation of venous disease. Out of the total, 1,631 patients with primary uncomplicated varicose veins were selected for this study: 1,383 (84.79% patients were female and 248 (15.21% were male. Mean age was 42.9 (± 0.48 years, ranging from 13 to 85 years. Of the 1,631 patients, 1,323 underwent bilateral

  3. Visualization of the Origin of the Vertebral Arteries with Color Doppler Sonography

    International Nuclear Information System (INIS)

    Yoon, Seok Hwan; Lee, Won Hong; Lee, Dae Hyung

    2009-01-01

    Atherosclerotic disease at the origin of the vertebral arteries is one of the risk factors for vertebrobasilar ischemic disease. Assessment and visualization of the origin of the vertebral arteries with color doppler sonography is a non-trivial task. The aim of this study is to increase the visualization rate of the origin of the vertebral arteries with color doppler sonography. Color doppler sonography for the vertebral arteries included carotid arteries was performed to 198 patients. We first examined the vertebral artery in the upper neck in the direction of the subclavian artery to distinguish its origin more easily. If the vertebral artery origin was not visualized in natural position, the examiner pushed the transducer toward a clavicle or pushed the shoulder of patient by the other hand. The technical methods for visualization of the vertebral artery origin were classified into three grades: natural position, pushing the transducer, and pushing the shoulder of patient according to the depth (3.0 cm and shallower, deeper than 3.0 cm) of the origin. The origin of the vertebral arteries could be visualized in 97% on the right and in 92% on the left. The origin of the vertebral arteries could be visualized in 98.6%, 1.4%, and 0.0% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 81.2%, 14.6%, and 4.2% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 85.4%, 10.7%, and 3.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the left side. The origin of the vertebral arteries could be visualized in 55.7%, 30.4%, and 13.9% in natural position, pushing the transducer, and pushing the shoulder of

  4. Contrast-enhanced color Doppler ultrasound characteristics in hypervascular breast tumors: comparison with MRI

    International Nuclear Information System (INIS)

    Alamo, L.; Fischer, U.

    2001-01-01

    The aim of this study was to evaluate the accuracy of contrast-enhanced color Doppler ultrasound (CE-US) in comparison with contrast-enhanced MR imaging (CE-MRI) in the discrimination of hypervascularized breast tumors. An additional CE-US of the breast was preoperatively performed in 40 patients with a hypervascular breast lesion detected on CE-MRI. The presence of blood flow signals and the morphological characteristics of the vessels in the breast lesions were evaluated pre- and post-contrast administration, as well as the dynamic aspects of the Doppler signal, including time interval to maximum signal enhancement and persistence of the signal enhancement. Twenty-three carcinomas and 17 fibroadenomas were explored. Considering initial signal enhancement > 100 % after the administration of contrast material as a criterion suggesting malignancy, CE-MRI showed a sensitivity of 100 % and a specificity of 76.5 % in the detection of malignant breast tumors. Color Doppler signals were consistently demonstrated in all carcinomas and in 68.7 % of fibroadenomas after the administration of Levovist, with CE-US showing a sensitivity of 95.6 % and a specificity of 5.9 %. Neither the mean number of vessels per tumor, nor the location of vessels, the time to maximum increase of the Doppler signal or the persistence of signal enhancement showed significant differences between benign and malignant lesions. Additional CE-US does not increase the low specificity of MRI in patients with hypervascularized breast tumors. (orig.)

  5. Choroid metastasis of papillary thyroid carcinoma. Color doppler ultrasound study

    International Nuclear Information System (INIS)

    Ganado, T.; Torre, S. de la; Contreras, E.; Hernandez, J.

    1997-01-01

    The most common causes of intraocular metastases are breast and lung cancers, although many other neoplasms can metastasize to the eye. Most of the metastases are located in the posterior pole and the choroid is more often involved than the retina. We present a case of a choroidal metastasis from a papillary carcinoma of the thyroid, associated with a massive subretinal hemorrhage. Findings with color Doppler ultrasound are emphasized. (Author) 9 refs

  6. The Diagnostic Value of Transvaginal Sonograph (TVS), Color Doppler, and Serum Tumor Marker CA125, CEA, and AFP in Ovarian Cancer.

    Science.gov (United States)

    Zhang, Fang; Zhang, Zhou-Long

    2015-06-01

    The purpose of this study is to investigate the diagnostic value of transvaginal sonograph (TVS), color Doppler, and serum tumor marker CA125, CEA, and AFP in ovarian cancer. From June, 2011 to May, 2013, 102 cases with adnexal mass were recruited in this study (32 cases of malignant ovarian cancer and 70 cases of benign ovarian tumor according to pathological diagnosis). TVS, color Doppler, and serum tumor markers were used for tumor diagnosis. The sensitivity, specifity, positive prediction, negative prediction, and Youden's index were analyzed. Of the 102 patients, 32 were diagnosed with malignant ovarian cancer and 70 were diagnosed with benign ovarian tumor according to pathological diagnosis. Based on TVS results, 37 cases were malignant while 65 cases were benign. Based on color Doppler results, 34 cases were malignant while 68 cases were benign. Based on TVS and color Doppler results, 35 cases were malignant while 65 were benign. Based on CA125 test results, 34 cases were malignant while 68 cases were benign. Based on CEA test results, 8 cases were malignant and 94 cases were benign. Bases on AFP test results, 9 cases were malignant while 93 cases were benign. Based on the results of combination tumor marker test, 38 cases were malignant while 64 cases were benign. The combination of TVS, color Doppler, and tumor marker test showed optimal diagnostic value with a sensitivity of 90.63 %, specificity of 97.14 %, positive prediction of 93.94 %, negative prediction of 98.55 %, and Youden's index of 94.02 %. The combination of TVS, color Doppler, and tumor marker test is of great diagnostic value, which should be widely used in clinical practice.

  7. Contrast-enhanced color Doppler US in breast cancer: Tumoral vascularity correlated with angiogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun A; Yoon, Kwon Ha; Yun, Ki Jung; Lee, Kwang Man; Park, Ki Han; Juhng, Seon Kwan; Won, Jong Jin [Wonkwang University School of Medicine, Seoul (Korea, Republic of)

    2000-12-15

    To evaluate the effects of contrast-enhanced color Doppler ultrasonography (CDUS) on the depiction of vascularity and flow pattern in breast cancer and to determine the relationship between tumoral vascularity and angiogenesis. Twenty-one patients with breast cancer were prospectively evaluated with CDUS before and after injection of the contrast agent (SH U 508A, 2.5g, 300 mg/ml ). The tumoral vascularity was expressed as percentage of color Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The flow pattern (four-patterns; spotty, linear, branching, marginal) of the vascularity was analyzed. After surgery, tumor angiogenesis was assessed by microvessel density. The relationship between the vascularity on CDUS and microvessel density was statistically analyzed. At unenhanced CDUS, tumoral flow signals were detected in 12 lesions (48%); at contrast-enhanced CDUS, 18 lesions (86%). All These 18 lesions showed increased signals, compared with those at unenhanced CDUS. The percentage color Doppler area was 1.86 {+-} 0.48% at unenhanced CDUS and 5.23 {+-} 1.18% at contrast-enhanced CDUS. The flow patterns before contrast injection were spotty pattern in 11 tumors and linear pattern in one; after contrast injection, spotty in 8, linear in 4, branching in 5, and marginal in one. The tumoral vascularity at contrast-enhanced CDUS showed no significant correlation with microvessel density. Contrast-enhanced CDUS seems to be a valuable tool in the depiction of vascularity and characterization of flow pattern in breast cancer. However, tumoral vascularity on CDUS may not reflect tumoral angiogenesis.

  8. Color-flow Doppler imaging in suspected extremity venous thrombosis

    International Nuclear Information System (INIS)

    Foley, W.D.; Middleton, W.D.; Lawson, T.L.; Hinson, G.W.; Puller, D.R.

    1987-01-01

    Color-flow Doppler imaging (CFDI) (Quanatum, 5 and 7.5 MHz, linear array) has been performed on 23 extremities (nine positive for venous thrombosis, 14 negative) with venographic correlation. CFDI criteria evaluated were venous color-flow respiratory variation, augmentation, compressibility, valve competence, and intraluminal echogenic filling defects. Both CFDI and venography were evaluated independently and prospectively. CFDI and venography agreed in all six cases of femoral vein thrombosis and eight of nine cases of popliteal vein thrombosis. CFDI was negative in one instance of recanalized popliteal vein thrombosis. Recanalized femoral vein thrombosis was documented in three patients by CFDI when the vein was nonopacified on conventional venography. CFDI provides a rapid and accurate assessment of the femoral popliteal venous system and can distinguish an occluded from a recanalized thrombus. Initial experience with auxiliary subclavian venous thrombus has produced equally accurate results

  9. Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs

    Directory of Open Access Journals (Sweden)

    Elzivânia G. Silva

    Full Text Available ABSTRACT: B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1, anterior chamber depth (M2, lens thickness (M3, lens length (M4, vitreous chamber depth (M5, optical disc length (M6 and optic nerve diameter (M7. Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS, final diastolic velocity (VDF, resistivity index (IR and pulse index (IP. No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05. The vitreous chamber depth (M5 was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05. The mean resistivity index (RI showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities

  10. [Vascular complications following kidney transplant: the role of color-Doppler imaging].

    Science.gov (United States)

    Granata, Antonio; Floccari, Fulvio; Lentini, Paolo; Vittoria, Salvatore; Di Pietro, Fabio; Zamboli, Pasquale; Fiorini, Fulvio; Fatuzzo, Pasquale

    2012-01-01

    The progressive decline in the incidence of graft rejection has made urological, surgical, parenchymal and vascular complications of kidney transplant more frequent. The latter, although accounting for only 5-10% of all post-transplant complications, are a frequent cause of graft loss. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of parenchymal and surgical complications of the transplanted kidney, its role is not fully understood in case of vascular complications of the graft. The specificity of Doppler ultrasound is very important in case of stenosis of the transplanted renal artery, pseudoaneurysms, arteriovenous fistulas, and thrombosis with complete or partial artery or vein occlusion. Doppler and color determinations present high diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of vascular complications of the transplanted kidney, planted kidney.

  11. Usefulness of hemodynamically distribution of intranodal vessels in differentiating metastatic neck lymph nodes-value of color doppler and spectral wave sonogram

    International Nuclear Information System (INIS)

    Mumtaz, U.

    2017-01-01

    Objective: To evaluate the diagnostic assessment of enlarged lymph nodes, based on its perfusion pattern by taking tissue diagnosis as gold standard. Study Design: Analytical study. Place and Duration of Study: Departments of Radiology and Pathology, PIMS Hospital, Islamabad, from February to May 2016. Methodology: Color sonography of patients with clinically, palpable cervical lymph nodes were carried by senior trainee under the supervision of senior radiologist. Ultrasound guided tissue diagnosis was obtained in all suspected malignant cases. Histopathology was taken as the gold standard for determining accuracy. Results: Accuracy, sensitivity and specificity, positive and negative predictive values of color Doppler ultrasound in detecting malignant cervical lymphadenopathy was found to be 88.46%, 86.05%, 79.31% and 92.50%, respectively with diagnostic accuracy of 86.95%, when intranodal vascular pattern on color Doppler imaging was analyzed. Using spectral wave indexes, the same values were 92.31%, 90.70%, 85.71%, 95.12%, respectively with overall diagnostic accuracy of 91.30%. Conclusion: Color Doppler sonography is much sensitive borderline than grey scale findings alone. Furthermore, lymph nodes appearing in the detection of malignant nodes on grey scale images can be reliably diagnosed on Doppler scan. (author)

  12. TORSION TESTIS : ROLE OF COLOR DOPPLER : A STUDY OF 50 CASES

    Directory of Open Access Journals (Sweden)

    Anand

    2015-09-01

    Full Text Available BACKGROUND: T orsion testis is one of the catast r ophic conditions in children and young a d u lts. Traditionally the diagnosis was made clinical presentation and suspicion. Critical decision making is essential to save the testis . OBJECTIVE: To study the usefu lness and efficacy of Doppler ultrasound in correctly diagnosing acute scrotal conditions in children and young adults to save the testis and to avoid negative explorations. METHODS: Over a period of two years 50 patients with acute scrotum were admitted i n general surgery department who underwent Doppler ultrasound scrotum and its efficacy in correctly diagnosing the pathology was analysed. RESULTS: 50 patients with age group <25 years were included in study. Scrotal pain was the most frequent presenting s ymptom of acute scrotum (98% followed by Swelling of the hemiscrolum on the involved side present in 86% of the patients. Doppler ultrasound showed torsion of testis in 18 patients. On Scrotal exploration, torsion of spermatic cord was confirmed in 16 pat ients, one patient had torsion of appendix of testis and the other had Epididymo - orchitis. Thus the sensitivity and specificity of Doppler ultrasonography for testicular torsion was 86.9% and 92.6% respectively. 2 patients with equivocal Doppler findings, but strong clinical suspicion of testicular torsion were explored, and testis was found to be torsed in both two patients. Doppler ultrasonography showed Epididymo - orchitis in 22 patients, torsion of testicular appendage in 2 patients, Idiopathic scrotal edema in one, and in 5 pts no significant pathology found. All twenty patients of epididymo - orchitis, two patients of torsion of testicular appendage, and one patient of idiopathic scrotal edema were managed conservatively. At three weeks follow up, all th e patients were free of symptoms. The sensitivity and specificity of Doppler ultrasonography for epididymo - orchitis was 95% and 100% respectively. CONCLUSIONS: color

  13. Bubble-Induced Color Doppler Feedback for Histotripsy Tissue Fractionation.

    Science.gov (United States)

    Miller, Ryan M; Zhang, Xi; Maxwell, Adam D; Cain, Charles A; Xu, Zhen

    2016-03-01

    Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high-intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with two-cycle histotripsy pulses at [Formula: see text] using a 500-kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression.

  14. Twinkling artifact on color Doppler ultrasound: an advantage or a pitfall?

    Science.gov (United States)

    Ozan, Ebru; Atac, Gokce Kaan; Gundogdu, Sadi

    2016-07-01

    The twinkling artifact (TA) or color comet-tail artifact is characterized by a rapidly changing mixture of red and blue color Doppler signals. Even though many diseases and clinical conditions have been shown to produce this artifact, its source is not clearly understood yet. The TA may provide additional information to gray-scale ultrasound findings in several clinical situations. However, there may be pitfalls to keep in mind. We must first be aware of the TA to benefit from the advantages and avoid the pitfalls. In this review, we aim to give practicing radiologists an overview of the mechanisms and clinical applications of the TA by illustrating sample cases we have encountered.

  15. Corpus luteum blood flow in normal and abnormal early pregnancy: evaluation and analysis with transvaginal color and pulsed doppler sonography

    International Nuclear Information System (INIS)

    Tang Xiaoyi; Lin Meifang; Zheng Meirong; Liang Xiaoxian; Liu Jianfeng

    2005-01-01

    Objective: Detecting and assessment the corpus luteum blood flow in normal and abnormal early pregnancy. Methods: Using transvaginal color and pulse Doppler sonography, we detected 215 pregnant women including 150 normal intrauterine pregnancies, 25 abortion, 29 ectopic pregnancies, and then recorded corpus luteum blood flow feature and the blood flow indexes (Vmax, RI and PI). Results: 1) Corpus luteum was successfully identified in 148 cases out of 150 of normal early pregnancies, 25 cases out of 26 of threatened abortion; 22 cases out of 29 of ectopic pregnancy. 2) Three groups shared the same feature of Color Doppler imaging: a circumferential rim around the entire corpus luteum. 3) The flow index revealed mean PVS, RI and PI had no statistical difference in normal and abnormal early pregnancy; The mean PVS was lower in ectopic pregnancy than in normal pregnancy (P<0.05), while PI and PR had no characteristic in ectopic pregnancy group compared with the indexes obtained in normal pregnancy group. Conclusion: The corpus luteum can be precisely identified in most pregnancy using transvaginal color Doppler and manifests a characterized rim Doppler imaging. PVS may help in differentiating the ectopic pregnancy from normal early pregnancy. (authors)

  16. Color Doppler ultrasound evaluation of asphyxial neonatal left ventricular function and its correlation with target organ damage

    Directory of Open Access Journals (Sweden)

    Cheng-Cai Chen

    2017-01-01

    Full Text Available Objective: To study the color Doppler ultrasound parameters of asphyxial neonatal left ventricular function and the correlation with target organ damage. Methods: Normal neonates, mildly asphyxial neonates and severely asphyxial neonates born in our hospital between January 2014 and December 2015 were selected as the control group (n = 46, mild asphyxia group (n = 37 and severe asphyxia group (n = 23 respectively. On the 1st day after birth, color Doppler ultrasound was used to evaluate left ventricular function, and serum was collected to determine myocardial tissue injury, brain tissue injury and brain tissue metabolism indexes. Results: Color Doppler ultrasound parameters cardiac output (CO, ejection fraction (EF and left ventricular fraction shortening (FS as well as serum folate and vitamin B12 content of mild asphyxia group and severe asphyxia group were significantly lower than those of control group (P<0.05 while serum creatine kinase isoenzyme (CK-MB, troponin I (cTnI, troponin T (cTnT, S100B, neuron-specific enolase (NSE, creatine kinase BB (CK-BB, glycogen phosphorylase BB (GPBB, and homocysteine (Hcy content were significantly higher than those of control group (P<0.05; CO, FS and EF as well as serum folate and vitamin B12 content of severe asphyxia group were significantly lower than those of mild asphyxia group (P<0.05 while serum CK-MB, cTnT, cTnI, S100B, NSE, CK-BB, GPBB and Hcy content were significantly higher than those of mild asphyxia group (P<0.05. Conclusions: Color Doppler ultrasound can accurately assess asphyxial neonatal left ventricular function damage degree and is closely related to myocardial tissue injury and brain tissue injury degree.

  17. Color doppler flow imaging in evaluation of uterine arterial embolization of leiomyoma with KMG

    International Nuclear Information System (INIS)

    Li Furong; Guo Yunhuai; Liu Lifang; Liu Jianhua; Guo Yunhuai

    2006-01-01

    Objective: To explore the effectiveness of a new kind of embolization agent-sodium alginate(KMG), and to evaluate the clinical value of 2D color Doppler ultrasound in assessing the therapeutic effect of uterine arterial embolization (UAE) in leiomyomas. Methods: Forty nine patients with symptomatic leiomyomas were undertaken UAE with KMG for the treatment. Sonography was performed at 3-7 days before and, 1, 3, 6 months after UAE with 2D color Doppler for evaluating the 2D echograms and hemodynamics. Results: Forty nine leiomyomas were studied after UAE, showing a marked reduction in the size (35%-90%). No blood flow was demonstrated in the leiomyomas either 3-7 days or 1 month or 3 months after the procedure. The reappearance of blood flow could be seen in only one case. Conclusion: KMG is an efficient embolization agent for the treatment of symptomatic leiomyomas with UAE, and ultrasonography is a useful tool to assess the effectiveness. (authors)

  18. Diagnosis of post-partum ovarian vein thrombophlebitis by color Doppler ultrasonography: about 10 cases.

    Science.gov (United States)

    Giraud, J R; Poulain, P; Renaud-Giono, A; Darnault, J P; Proudhon, J F; Grall, J Y; Mocquet, P Y

    1997-09-01

    Post-partum ovarian vein thrombosis is often overlooked or mistaken for other complications such as endometritis. Color Doppler ultrasonography is a very good diagnostic method when properly indicated and correctly interpreted according to clinical data. This study reports ten cases that were retrospectively studied, during which color Doppler ultrasonography was used. The clinical signs and the results are reviewed. The lesions were clearly visualized in eight of the ten cases; one of the two failures resulted from a methodological fault (uninterpretable result); the other one was due to the lack of experience of the operator and nonrecognition of the clinical signs. Thrombosis appears as a hypoechogenic and tubular image. This type of examination is particularly indicated in the presence of certain clinical signs that were observed in our cases: fever and iliac pain are the main precursor signs, often associated with abdominal meteorism and slow digestive transit; provoked cul-de-sac pain during vaginal probing was the only constant sign, sometimes associated with painful swelling.

  19. Value of downstream circulation in renal artery stenosis with arterial hypertension: comparison between color Doppler flow and digital renal angiography in 123 patients

    International Nuclear Information System (INIS)

    Grataloup, C.; Challande, P.; Plainfosse, M.C.; Girerd, X.; Belattar, K.; Plouin, P.F.

    1996-01-01

    Digital renal angiography and color Doppler flow were compared for diagnosis of renal artery stenosis in 123 hypertensive patients with a prevalence of renal artery stenosis ≥75% of 21 %. Only color Doppler flow signs found downstream from the stenosis could be quantified. A rising time (RT) >0.07 s was the best marker for renal artery stenosis ≥ 75 % according to a receiver operating characteristic curve with a specificity of 97 %, a sensitivity of 88 %, a positive predictive value of 86 %, a negative predictive value of 98 % and an accuracy of 96 %. Digital renal angiography and color Doppler flow findings for renal artery lesions were classified into 4 degrees with agreement for 86 % of the kidneys. (authors). 13 refs., 5 figs., 8 tabs

  20. [Usefulness of transvaginal Doppler color in ovarian neoplasms diagnosis].

    Science.gov (United States)

    Muñoz, H; Martínez, L; Parra, M; Cunill, E; Polanco, M; Leible, S; Romero, C

    1993-01-01

    The vascular resistant evaluation by Doppler waveform is a method used in clinic and research. The neoplastic malignant has an increased growth with an increased amount of neomalignant vessels. The presence of these vessels produce an increase of the transversal section area from the tumoral vascular system, therefore there is a decrease in the vascular resistance. The main objective of this work is to show the usefulness of Doppler waveform as predictor factor of malignity in ovary tumors. Eighteen patients with tumoral mass in the ovary were studied. They were between 21 and 67 years old (mean = 43). The tumoral volume and the flow resistance of blood vessels which irrigated those tumoral mass were evaluated by transvaginal ultrasound with color and pulsed Doppler. The pulsatility index (SD/media) was used. The Chi cuadrado test was used to evaluate the results. The results show the presence of six malignant tumors, three of them with low malignicity and the presence of twelve benign tumors. The age of the patients between both groups (malignant and benign tumors) were significant different (40.7 versus 52 years old, p < 0.001). The mean tumoral volume was 65 ml, with a range of 17 to 225 ml in the group of patients with benign tumors and the mean tumoral volume from patients with malignant tumors was 951 ml with a range of 141 to 3142 ml. The difference in the tumoral in both groups was significative with p < 0.001.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Preload dependence of color M-mode Doppler flow propagation velocity in controls and in patients with left ventricular dysfunction

    DEFF Research Database (Denmark)

    Møller, J E; Poulsen, S H; Søndergaard, E

    2000-01-01

    The purpose of this study was to assess the effects of preload alterations on color M-mode flow propagation velocity (Vp) in volunteers with normal left ventricular (LV) function and in patients with depressed LV function. Color M-mode Doppler echocardiography was performed during Valsalva maneuv...

  2. Assessment of ureterovesical jet dynamics in obstructed ureter by urinary stone with color Doppler and duplex Doppler examinations.

    Science.gov (United States)

    Jandaghi, Ali Babaei; Falahatkar, Siavash; Alizadeh, Ahmad; Kanafi, Alireza Rajabzadeh; Pourghorban, Ramin; Shekarchi, Babak; Zirak, Amin Keshavarz; Esmaeili, Samaneh

    2013-04-01

    This study was designed to evaluate ureterovesical jet dynamics in obstructed ureter and to compare it with those of contralateral unobstructed side. Forty-six patients with diagnosis of ureteral stone, based on imaging findings in computed tomography were enrolled in this study. The gray-scale ultrasound exam from both kidneys and urinary bladder was performed. Then, ureterovesical jet characteristics including ureteral jet frequency, duration and peak velocity were assessed by color Doppler and duplex Doppler studies in both obstructed and unobstructed ureters by a radiologist, 15-30 min after oral hydration with 750-1,000 mL of water. When compared with contralateral normal side, the ureterovesical jet in obstructed ureter showed less frequency (0.59 vs. 3.04 jets/min; P < 0.05), shorter duration (1.24 vs. 5.26 s; P < 0.05) and lower peak velocity (5.41 vs. 32.09 cm/s; P < 0.05). The cut-off points of 1.5 jets/min, 2.5 s and 19.5 cm/s for difference of ureteral jet frequency, duration and peak velocity between obstructed and contralateral normal ureters yielded sensitivities of 97.8, 95.6 and 100 % and specificities of 87, 87.9 and 97.8 %, respectively for diagnosis of ureteral obstruction. Given the safety of Doppler study and significant differences in flow dynamics of obstructed versus unobstructed ureters, our findings demonstrated the utility of Doppler ultrasound examination as a useful adjunct to gray-scale ultrasound by improving the accuracy of ultrasound exam in diagnosis of ureteral obstruction.

  3. High-flow-velocity and shear-rate imaging by use of color Doppler optical coherence tomography

    NARCIS (Netherlands)

    van Leeuwen, T. G.; Kulkarni, M. D.; Yazdanfar, S.; Rollins, A. M.; Izatt, J. A.

    1999-01-01

    Color Doppler optical coherence tomography (CDOCT) is capable of precise velocity mapping in turbid media. Previous CDOCT systems based on the short-time Fourier transform have been limited to maximum flow velocities of the order of tens of millimeters per second. We describe a technique, based on

  4. [The diagnostic performance of color Doppler ultrasonography for newborn four cases of midgut volvulus accompanied by intestinal malrotation].

    Science.gov (United States)

    Ikeshima, Yukari; Hisano, Katsuya; Morisawa, Takeshi; Inoue, Kozue; Shimamoto, Masahiro; Koujitani, Toshiaki; Yonetani, Masahiko; Yasufuku, Masao

    2014-03-01

    Midgut volvulus accompanied by intestinal malrotation is classified as a surgical emergency disease of the newborn, which emerges with the bilious vomiting or melena. This report presents four patients of this disease in our hospital, evaluated by color Doppler ultrasonography before surgical operation. All four patients were presented by bilious vomiting at the onset. By color Doppler ultrasonography method, the whirlpool sign which is the view of intestine and superior mesenteric vein rotated around with the axis of superior mesenteric artery, were shown in all cases. This whirlpool sign led to the diagnosis of midgut volvulus accompanied by intestinal malrotation. Intestinal contrast imaging was tested in three patients for the purpose of confirming the diagnosis. Repair of the volvulus and a ladd operation was performed in all four patients, without the excision of intestine because of no intestinal ischemic change. The clinical courses of four cases were good, and all patients were discharged within 17 days. Early diagnosis and timely surgical operation are essential for decreasing the possibility of occurring intestinal ischemic changes and improving clinical outcome after surgical operation. We propose that color Doppler ultrasonography is the powerful tool for the diagnosis of this disease, especially for the newborn, for whom the available diagnostic tests are limited.

  5. Association of maternal and umbilical cord blood leptin concentrations and abnormal color Doppler indices of umbilical artery with fetal growth restriction

    Directory of Open Access Journals (Sweden)

    Elahe Zareaan

    2017-08-01

    Full Text Available Background: Fetal growth restriction (FGR is a condition with heterogeneous pathophysiology which characterized by fetal weight less than the tenth percentile for gestational age. Several factors have impact on maternal, placental and fetal due to growth restriction. Objective: The aim of this study was to investigate the relationship between levels of leptin in the cord, and serum leptin of mothers also abnormal color Doppler indices of umbilical artery with fetal growth restriction. Materials and Methods: This is a cross sectional study conducted in Isfahan, Iran, 2015-2016. We recruited 40 women with singleton pregnancies complicated by fetal growth restriction (Group I and 40 pregnant women with normal fetal growth (Group II with matched age. Maternal serum and umbilical artery leptin levels were determined with Enzyme-Linked immunosorben method. Also, color Doppler ultrasound of umbilical artery was performed. Results: Mean maternal and fetal leptin levels were lower in the FGR group compared to the normal group (36.58±(20.99 and 7.42 ±(4.08vs. 47.32±(22.50 and 30.49±(14.50 respectively. Also, mean fetal leptin level was lower in the group with abnormal color Doppler sonographic indices compared to the normal group (7. 40 ±(4.10vs 27.06±(15.80, respectively. Conclusion: This study indicated that maternal and fetal leptin levels are correlated with FGR originating from damaged placental function; also fetal leptin level can indicate changes in color Doppler sonographic indices.

  6. Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

    Science.gov (United States)

    Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.; hide

    2001-01-01

    Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

  7. Cavernous hemangioma of liver: a comparative study of MRI and color Doppler ultrasound (with 58 case report)

    International Nuclear Information System (INIS)

    Luan Zhiyong; Xu Weidong; Wang Jiazhong

    2006-01-01

    Objective: To evaluate MRI and the color Doppler ultrasound in the diagnosis of cavernous hemangioma of liver. Methods: In total 58 patients with hemangioma of liver underwent dynamic enhanced MRI and the color Doppler ultrasound examination. The imaging manifestations obtained by both modalities were comparatively studied. Result: Highly echoic lesions were revealed in 36 cases out of 58; low echoic lesions were noted in 8; and in 14 cases the tumors were of mixed echoic. On T 1 WI the lesions were hypo- or slightly hypo-intense; while on T 2 WI they were hyper- or slightly hyper-intense. The nidi were hyper-intense on T 2 WI of CRE array. On enhanced scan the lesions were quickly fully enhanced in 25 cases out of 58. Peripheral nodular enhancement was seen in 19 cases, and centered spreading enhancement was demon- strated in 14 cases. On delayed scan remarkable homogenous enhancement was observed in all cases. Conclusion: The bigger size has the hemangioma, the smaller highly echoic proportion and bigger mixed echoic or poorly echoic proportion will be found within the lesions. More peripheral nodular enhancement will be revealed on enhanced MRI scan when the tumor size is getting larger, in which the proportion of quickly fully enhancement will decrease gradually. Ultrasound is better than MRI in the evaluation of the liver hemangioma smaller than 3 cm in diameter. MRI is superior to color Doppler ultrasound in diagnosing the lesion larger' than 3 cm in diameter. (authors)

  8. Color M-mode Doppler flow propagation velocity is a preload insensitive index of left ventricular relaxation: animal and human validation.

    Science.gov (United States)

    Garcia, M J; Smedira, N G; Greenberg, N L; Main, M; Firstenberg, M S; Odabashian, J; Thomas, J D

    2000-01-01

    To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.

  9. Experimental study on blood flow patterns through the phantoms of the intracranial arterial aneurysms using color Doppler imaging

    International Nuclear Information System (INIS)

    Chung, Tae Sub; Jeong, Eun Kee; Rhim, Yoon Chul; Kim, Sung Bin; Lee, Dong Hoon; Kim, Dae In

    1994-01-01

    The occurrence, growth, thrombosis, and rupture of intracranial saccular aneurysms can be directly related to the effect of hemodynamic forces. We developed the phantom flow models and compared with the computer simulation program to analyse the flow pattern and hemodynamics that might be responsible for the intracranial arterial aneurysms. We designed the arterial phantoms of three major sites of intracranial arterial aneurysm ; 1) basilar artery tip, 2) internal carotid artery bifurcation, 3) curved area of internal carotid artery. Flow patterns in the aneurysmal portion of phantoms were evaluated with color Doppler system on the connection with automatic closed type of circulation system. Then, we compared the results with computer simulation. The hemodynamic characteristics of the phantoms were identical with those obtained by computerisation's. Three distinct zones of flow were identified by color Doppler studies on the aneurysm of the curved area of an internal carotid artery : 1) an inflow zone entering the aneurysm at the distal aspect of its orifice, 2) an outflow zone exiting the aneurysm at the proximal aspect of its orifice, 3) a central slow vortex.However, the phantoms of basilar artery tip and artery bifurcation showed a direct inflow stream at the dome of an aneurysm. Flow dynamics in the various phantoms of the aneurysms can be successfully evaluated with color Doppler imaging, and were consistent with those predicted by computer simulations

  10. Pulsed-wave tissue Doppler and color tissue Doppler echocardiography: calibration with M-mode, agreement, and reproducibility in a clinical setting

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; Jons, Christian; Fritz-Hansen, Thomas

    2009-01-01

    BACKGROUND: Myocardial velocities can be measured with both pulsed-wave tissue Doppler (PWTD) and color tissue Doppler (CTD) echocardiography. We aimed to (A) to explore which of the two methods better approximates true tissue motion and (B) to examine the agreement and the reproducibility...... of the two methods in a routine clinical setting. METHODS: For Study A, the displacements of 63 basal myocardial segments from 13 patients were examined with M-mode and compared with the velocity-time integral of PWTD and CTD velocities. For Study B, the basal lateral segments from 58 patients were examined...... with PWTD and CTD, and the peak myocardial velocities during systole (Sm), early diastole (Em), and late diastole (Am) were measured. RESULTS: Study A: CTD-based measurements of displacement were 12% lower than M-mode measurements (95% CI: -18%; -6%). PWTD velocity-time integrals measured at the outer edge...

  11. Discrimination between pleural thickening and minimal pleural effusion using color Doppler chest ultrasonography

    OpenAIRE

    Hasan, Ali A.; Makhlouf, Hoda A.; Mohamed, Alaa R.M.

    2013-01-01

    Background: The discrimination of pleural thickening from minimal pleural effusion may be difficult as both lesions appear as anechoic on grayscale ultrasound, hence, free of “echoes” does not confirm the presence of pleural fluid. Aim of this study: To evaluate the value of color Doppler ultrasound in differentiating minimal pleural effusion that could be aspirated from pleural thickening and to compare it with grayscale ultrasound. Patients and methods: This analytic cross-sectional s...

  12. The diagnosis value of color doppler ultrasound in evaluating small renal carcinoma

    International Nuclear Information System (INIS)

    Chen Gaiyi

    2009-01-01

    Objective: To characterize the ultrasound and color doppler imaging of small renal carcinoma. Methods: Ultrasound and color doppler images by convex-probe and high frequency-probe of 24 patients with renal carcinoma confirmed by surgery and histology were analyzed retrospectively. Tumor echo, halo, internal blood flow and peripheral tumor blood flow were observed. Results: Tumor echo in 9 lesions was hyper-echo, in 4 was iso-echoic, in 10 was hypo-echo, and in 1 was echoless. Halo was detected in 9 tumors, and small cyst was detected in 5 tumors. By using the convex-probe, peripheral and internal blood flow signal in 24 tumors were observed. Spot blood follow was detected in 6 tumors, half-circularity blood follow in 18 tumors and no circularity blood follow. Detection rate of internal blood flow was 20.83%. By using the high frequency-probe in 21 tumors, spot blood was detected in 1 tumor, half-circularity blood follow in 14 tumors, circularity blood follow in 6 tumors. Detection rate of internal blood flow was 90.48%. It was not satisfied for high frequency-probe in 3 patients because of obesity. Accordance of the diagnosis by high frequency-probe ultrasound was 90.48% and 91.67% by CT (P > 0.05). Conclusion: Detection of renal carcinoma is sensitive by ultrasound. The high frequency-probe is significant sensitive to detect blood follow in renal carcinoma and is helpful to correct diagnosis of renal carcinoma. (authors)

  13. The application of color Doppler flow imaging in the diagnosis and therapeutic effect evaluation of erectile dysfunction

    Directory of Open Access Journals (Sweden)

    Xu-Jun Xuan

    2016-01-01

    Full Text Available We aim to investigate the correlations between hemodynamic parameters, penile rigidity grading, and the therapeutic effects of phosphodiesterase type 5 inhibitors using color Doppler flow imaging after intracavernosal injection in patients with erectile dysfunction. This study involved 164 patients. After intracavernosal injection with a mixture of papaverine (60 mg, prostaglandin E 1 (10 mg, and lidocaine (2%, 0.5-1 ml, the penile vessels were assessed using color Doppler flow imaging. Penile rigidity was classified based on the Erection Hardness Score system as Grades 4, 3, 2 or 1 (corresponding to Schramek Grades V to II. Then, the patients were given oral sildenafil (50-100 mg and scored according to the International Index of Erectile Function (IIEF-5 questionnaire. The number of patients with penile rigidities of Schramek Grades II to V was 14, 18, 21, and 111, respectively. The IIEF-5 score was positively correlated with the refilling index of the penile cavernosal artery (r = 0.79, P< 0.05, the peak systolic velocity (r = 0.45, P< 0.05, and penile rigidity (r = 0.75, P< 0.05, and was negatively correlated with the end diastolic velocity (r = −0.74, P< 0.05. For patients with erectile dysfunction, both the IIEF-5 score after sildenafil administration, which is correlated with penile rigidity, and the hemodynamic parameters detected using color Doppler flow imaging may predict the effects of phosphodiesterase type 5 inhibitor treatment and could provide a reasonable model for the targeted-treatment of erectile dysfunction.

  14. In-vivo imaging of blood flow in human retinal vessels using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    1999-04-01

    Quantification of retinal blood flow may lead to a better understanding of the progression and treatment of several ocular disorders, including diabetic retinopathy, age- related macular degeneration, and glaucoma. Current techniques, such as fluorescein angiography and laser Doppler velocimetry are limited, failing to provide sufficient information to the clinician. Color Doppler optical coherence tomography (CDOCT) is a novel technique using coherent heterodyne detection for simultaneous cross- sectional imaging of tissue microstructure and blood flow. This technique is capable of high spatial and velocity resolution imaging in highly scattering media. We implemented CDOCT for retinal blood flow mapping in human subjects. No dilation of the pupil was necessary. CDOCT is demonstrated for determining bidirectional flow in sub- 100micrometers diameter vessels in the retina. Additionally, we calculated Doppler broadening using the variance of depth- resolved spectra to identify regions with large velocity gradients within the Xenopus heart. This technique may be useful in quantifying local tissue perfusion in highly vascular retinal tissue.

  15. Color-flow Doppler US usefulness in upper-extremity venous thrombosis

    International Nuclear Information System (INIS)

    Grassi, C.J.; Polak, J.F.

    1988-01-01

    Compared with its application in the leg veins, US has been used infrequently in the axillary-subclavian veins. Using color-flow Doppler US (CFDUS) as the primary means of follow-up, seven patients from a consecutive 120 venograms in the subgroup of effort thrombosis were restudied to compare CFDUS with venography in blinded fashion. In all seven patients, CFDUS allowed prediction of the thrombus location and the collateral veins; swirl (turbulent venous flow) was detected in two patients, asymmetric jugular distention was seen in three, and the normal response on inspiration was vein collapse, The authors experience indicates the CFDUS shows good correlation with axillary-subclavian venography, that blind areas behind the clavicle can be overcome, and that CFDUS may be preferable in follow-up to avoid patient discomfort or contrast material-induced phlebitis

  16. In-vivo imaging of blood flow dynamics using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    2000-04-01

    Noninvasive quantitation of blood flow in the retinal micro circulation may elucidate the progression and treatment of ocular disorders including diabetic retinopathy, age-related degeneration, and glaucoma. Color Doppler optical coherence tomography was recently introduced as a technique allowing simultaneous micron-scale resolution cross-sectional imaging of tissue micro structure and blood flow in the human retina. Here, time-resolved imaging of dynamics of blood flow profiles was performed to measure cardiac pulsatility within retinal vessels. Retinal pulsatility has been shown to decrease throughout the progression of diabetic retinopathy.

  17. Basal ganglia perfusion using dynamic color Doppler sonography in infants with hypoxic ischemic encephalopathy receiving therapeutic hypothermia: a pilot study.

    Science.gov (United States)

    Faingold, Ricardo; Cassia, Guilherme; Morneault, Linda; Saint-Martin, Christine; Sant'Anna, Guilherme

    2016-10-01

    The objective of this study was to evaluate the cerebral perfusion of the basal ganglia in infants with hypoxic-ischemic encephalopathy (HIE) receiving hypothermia using dynamic color Doppler sonography (CDS) and investigate for any correlation between these measurements and survival. Head ultrasound (HUS) was performed with a 9S4 MHz sector transducer in HIE infants submitted to hypothermia as part of their routine care. Measurements of cerebral perfusion intensity (CPI) with an 11LW4 MHz linear array transducer were performed to obtain static images and DICOM color Doppler videos of the blood flow in the basal ganglia area. Clinical and radiological data were evaluated retrospectively. The video images were analyzed by two radiologists using dedicated software, which allows automatic quantification of color Doppler data from a region of interest (ROI) by dynamically assessing color pixels and flow velocity during the heart cycle. CPI is expressed in cm/sec and is calculated by multiplying the mean velocity of all pixels divided by the area of the ROI. Three videos of 3 seconds each were obtained of the ROI, in the coronal plane, and used to calculate the CPI. Data are presented as mean ± SEM or median (quartiles). A total of 28 infants were included in this study: 16 male, 12 female. HUS was performed within the first 48 hours of therapeutic hypothermia treatment. CPI values were significantly higher in the seven non-survivors when compared to survivors (0.226±0.221 vs . 0.111±0.082 cm/sec; P=0.02). Increased perfusion intensity of the basal ganglia area within the first 48 of therapeutic hypothermia treatment was associated with poor outcome in neonates with HIE.

  18. Role of color Doppler US in the evaluation of uterine leiomyoma treated with gonadotrophin-releasing hormone (GnRH) agonist (Zoladex)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Sik; Sohn, Cheol Ho; Lee, Tae Sung [Keimyung University Dongsan Medical Center, Taegu (Korea, Republic of)

    1999-03-15

    To access the role of color Doppler US in the evaluation of uterine leiomyoma treated with GnRH agonist (Zoladex). Out of 25 patients with uterine leiomyoma treated with Zoladex, nineteen cases of leiomyoma in 18 women who had US examination before and after medication were included in this study. Zoladex was injected subcutaneously three times within three months. Both gray scale and color Doppler US were obtained before and 1-3 months after the medication. The size, volume, location and internal echoes of the leiomyoma were recorded with gray scale US. Changes in the amount of color signal within leiomyomas were recorded. Pulsatility index (PI), resistive index (RI), peak systolic velocity (PSV) of both uterine artery and arteries within leiomyomas were also recorded. The image findings of good response group and poor response group in which the volume reduction of the leiomyoma was above or below 50% respectively were compared with each other. The reduction of the volume of leiomyoma was compared between a group with decrease in the amount of color signals during follow-up US and a group with increase or no change. Mean reduction of the volume of leiomyomas was 52%. Changes in the amount of color signals of the leiomyoma, PI, RI, PSV obtained from the arteries within leiomyomas were not correlated with the change of the volume of leiomyomas. PSV of uterine artery in one month follow-up and PI of two month follow-up were correlated with the changes of the volume of leiomyomas (p<0.05). RI of uterine artery in two month follow-up was useful in prediction of the good response group and the poor response group (p<0.05). The prediction of the volume reduction of leiomyoma following Zoladex medication might be possible by obtaining RI of uterine artery in two month follow-up. Doppler US of the arteries within the leiomyoma was not useful.

  19. Role of color Doppler US in the evaluation of uterine leiomyoma treated with gonadotrophin-releasing hormone (GnRH) agonist (Zoladex)

    International Nuclear Information System (INIS)

    Kim, Jung Sik; Sohn, Cheol Ho; Lee, Tae Sung

    1999-01-01

    To access the role of color Doppler US in the evaluation of uterine leiomyoma treated with GnRH agonist (Zoladex). Out of 25 patients with uterine leiomyoma treated with Zoladex, nineteen cases of leiomyoma in 18 women who had US examination before and after medication were included in this study. Zoladex was injected subcutaneously three times within three months. Both gray scale and color Doppler US were obtained before and 1-3 months after the medication. The size, volume, location and internal echoes of the leiomyoma were recorded with gray scale US. Changes in the amount of color signal within leiomyomas were recorded. Pulsatility index (PI), resistive index (RI), peak systolic velocity (PSV) of both uterine artery and arteries within leiomyomas were also recorded. The image findings of good response group and poor response group in which the volume reduction of the leiomyoma was above or below 50% respectively were compared with each other. The reduction of the volume of leiomyoma was compared between a group with decrease in the amount of color signals during follow-up US and a group with increase or no change. Mean reduction of the volume of leiomyomas was 52%. Changes in the amount of color signals of the leiomyoma, PI, RI, PSV obtained from the arteries within leiomyomas were not correlated with the change of the volume of leiomyomas. PSV of uterine artery in one month follow-up and PI of two month follow-up were correlated with the changes of the volume of leiomyomas (p<0.05). RI of uterine artery in two month follow-up was useful in prediction of the good response group and the poor response group (p<0.05). The prediction of the volume reduction of leiomyoma following Zoladex medication might be possible by obtaining RI of uterine artery in two month follow-up. Doppler US of the arteries within the leiomyoma was not useful.

  20. Magnetic resonance angiography in renal grafts. Comparison with color Doppler echography

    International Nuclear Information System (INIS)

    Yanagisawa, Takayoshi; Otsubo, Osamu; Nozaki, Harushige

    1995-01-01

    We studied relationship between magnetic resonance angiography (MRA) of renal graft and renal graft function in 14 renal transplantations (10 from living donors, 4 from cadaveric donors). MRA was performed on 0.3-T permanent magnet system (MRP 7000, HITACHI, JAPAN) using 2 dimensional time of flight technique (FOV: 350 mm 2 , RT: 60 msec, ET: 10 msec, FA: 90deg, Slice: volumes 60, thickness 4 mm, overlap 1 mm). As for parameters of renal graft function, we evaluated color doppler echography (CD) of transplanted renal artery, renal blood flow (RBF), velocity of interlobar artery (ILA) and serum creatinine level (S-Cr). CD, RBF and velocity of ILA were visualized and measured by duplex color doppler echosystem (EUB-565A, HITACHI, JAPAN). Depending on visualization of transplanted renal artery, MRA was graded into 3 groups (MA Grade 3: visualization of ILA, MA Grade 2: visualization of segmental artery and the first branch but no visualization of ILA, MA Grade 1: visualization of main renal artery only). Likewise, visualization of CD was graded into 3 groups (CD Grade 3: good visualization of arcuate artery (AA) and ILA, CD Grade 2: poor visualization of AA but good visualization of ILA, CD Grade 1: poor visualization of ILA). The MRA grading had a very significant correlation (r=0.79, p<0.001) with the CD grading. As for RBF and velocity of ILA, the RBF of MA Grade 3 group (n=8) was significantly (p<0.05) higher than the MA Grade 2 group (n=4) and the MA Grade 1 group (n=2), and the velocity of ILA of MA Grade 3 group was also higher than the above groups but not significantly. Furthermore, the S-Cr of MA Grade 3 was significantly (p<0.05) lower than the others. These results showed that MRA of renal graft had a qualitative index of renal graft function. (author)

  1. Does color Doppler sonography improve the clinical assessment of patients with acute scrotum?

    International Nuclear Information System (INIS)

    Pepe, Pietro; Panella, Paolo; Pennisi, Michele; Aragona, Francesco

    2006-01-01

    Introduction and objectives: Our experience concerning the use of color Doppler sonography (CDS) in the differential diagnosis of acute scrotum is reported. Material and methods: From July 2000 to July 2005, 155 patients (median 17.2 years) were admitted with a diagnosis of acute scrotum (unilateral in 150 cases, bilateral in 5). Along with a careful anamnesis and the physical exam, all patients underwent a CDS study of the scrotal content using a sonograph GE Logiq 500 with a multifrequency (7.5-10 MHz) linear probe Small Part. The following CDS parameters were evaluated: intensity of the color-power signal on the testicular parenchyma and on the epididymis; systolic peak velocity (SPV) and telediastolic velocity (TDV) in correspondence of the gonadal hilum. Ultrasound and flowmetry parameters registered on the painful testis were compared with those registered on the healthy controlateral testis. The reduction/absence versus the increase of color-power signal in the parenchyma and the reduction/absence versus the increase of SPV and TDV in the centripetal intratesticular arteries were considered presumptive of testicular torsion versus orchiepididymitis. Results: The results only refer to the 150 patients (300 testis) with acute monolateral scrotum. The clinical picture and the physical exam suggested a torsion of the spermatic cord in 40 cases, a spontaneous de-torsion in 5, an orchiepididymitis in 80, a blunt scrotal trauma in 15, a bulky epididymal cyst or a hydrocele in 4 and a testicular pain of unknown etiology in the remaining 6 cases. Standard US was pathological in 95 patients (63.3%); CDS was pathologic in 70 patients and in 42 of them suggested a testicular torsion. Fifty-three patients underwent surgical exploration: among 42 patients with a presumptive diagnosis of testicular torsion, the diagnosis was confirmed in 22 cases, no anomaly was found in 16 cases and in 4 patients a torsion of testicular appendix was found. The rupture of the tunica

  2. Incertidumbres en Mediciones de Caudal con Perfiladores de Corriente Acústicos Doppler desde Plataformas Móviles

    OpenAIRE

    Tarrab, Leticia

    2014-01-01

    Tesis (DCI)--FCEFN-UNC, 2013 Determina la incertidumbre en las mediciones de caudal con Perfiladores de Corriente Acústicos Doppler (ADCP) desde plataformas móviles a los fines de optimizar las técnicas de medición y elaborar recomendaciones para minimizar los errores (sesgo e incertidumbre aleatoria) en el uso de las técnicas de medición de caudales.

  3. Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors

    International Nuclear Information System (INIS)

    Kettenbach, Joachim; Helbich, Thomas H.; Huber, Sabine; Zuna, Ivan; Dock, Wolfgang

    2005-01-01

    Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound

  4. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    OpenAIRE

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in f...

  5. Intra and interobserver variability of renal allograft ultrasound volume and resistive index measurements; Variabilita' intra- ed interoperatore delle misure ecografiche del volume e dell'indice di resistenza del rene trapiantato

    Energy Technology Data Exchange (ETDEWEB)

    Mancini, Marcello; Liuzzi, Raffaele [CNR, Napoli (Italy). Istituto di biostrutture e bioimmagini; Daniele, Stefania; Raffio, Teresa; Salvatore, Marco [Napoli Univ., Napoli (Italy). Dipartimento di diagnostica per immagini; Sabbatini, Massimo; Cianciaruso, Bruno [Napoli Univ., Napoli (Italy). Istituto di nefrologia medica; Ferrara, Liberato Aldo [Napoli Univ., Napoli (Italy). Dipartimento di medicina clinica e sperimentale

    2005-04-01

    Purpose: Aim of the presents study was to evaluate the repeatability and reproducibility of the Doppler Resistive Index (R.I.) and the Ultrasound renal volume measurement in renal transplants. Materials and methods: Twenty -six consecutive patients (18 men, 8 women) mean age of 42,8{+-}12,4 years (M{+-}SD)(range 22-65 years) were studied twice by each of two trained sonographers using a color Doppler ultrasound scanner. Twelve of them had a normal allograft function (defined as stable serum creatinine levels {<=}123,76 {mu}mol/L), whilst the remaining 14 had decreased allograft function (serum creatinine 132.6-265.2 {mu}mol/L). Results were given as mean of 6 measurements performed at upper, middle and lower pole of the kidney. Intra- and interobserver variability was assessed by the repeatability coefficient and coefficient of variation (CV). Results: Regarding Resistive Index measurement, repeatability coefficient was between 0.04 and 0.06 and the coefficient of variation was <5%. The analysis of the Student's test did not show any significant difference between the measurements (t=0.15; p=0.87 n.s.). A good reproducibility was also detected in US measurements of renal length and volume. Conclusions: These results suggest that Color Doppler Resistive Index measurements of renal allograft and Ultrasound renal volume measurements are repeatable and reproducible. [Italian] Scopo: Valutare la ripetibilit� e la riproducibilit� delle misurazioni ecografiche dell'Indice di Resistenza (I.R.) e del volume del rene trapiantato. Materiale e metodi: Ventisei pazienti (18 uomini, 8 donne) con et� media di 42,8{+-}12,4 anni (M{+-}SD)(range 22-65 anni) sono stati studiati consecutivamente due volte con eco-color-Doppler da due ecografisti esperti. Dodici pazienti avevano funzione renale normale (livello serico di creatina stabilmente {<=}123,76 {mu}mol/L, i rimanenti 14 avevano una lieve e stabile disfunzione del rene trapiantato (creatina serica 132.6-265.2 {mu

  6. Contribution of spiral artery blood flow changes assessed by transvaginal color Doppler sonography for predicting endometrial pathologies

    Directory of Open Access Journals (Sweden)

    Suna Kabil Kucur

    2013-01-01

    Full Text Available ive: To investigate the diagnostic value of blood flow measurements in spiral artery by transvaginal color Doppler sonography (CDS in predicting endometrial pathologies.Methods: Ninety-seven patients presenting with abnormal uterine bleeding and requiring endometrial assessment were included in this prospective observational study. Endometrial thickness, structure and echogenicity were recorded. Pulsatility index (PI and resistive index (RI of the spiral artery were measured by transvaginal CDS. Endometrial sampling was performed for all subjects. Sonographic and hystopathologic findings were compared.Results: The histopathological diagnoses were as follows; 39 cases (40.2% endometrial polyp, 9 cases (9.3% endometrial hyperplasia, 10 cases (10.3 submucous myoma, 7 cases (7.2% endometrium cancer, and 32 cases (33% nonspecific findings. The spiral artery PI in endometrium cancer group was highly significantly lower than other groups (p<0.01. The spiral artery RI was also significantly lower in the patients with malignant histology (p<0.05. Conclusion: Endometrial pathologies are associated significantly with endometrial spiral artery Doppler changes.Key words: Spiral artery, Doppler ultrasonography, endometrium

  7. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  8. ZETA POTENTIAL AND COLOR INVESTIGATIONS OF VEGETABLE OIL BASED EMULSIONS AS ECO-FRIENDLY LUBRICANTS

    Directory of Open Access Journals (Sweden)

    ROMICĂ CREŢU

    2017-06-01

    Full Text Available In the past 10 years, the need for biodegradable lubricants has been more and more emphasized. The use of vegetable oils as lubricants offers several advantages. The vegetable oils are biodegradable; thus, the environmental pollution is minimal either during or after their use. The aim of this paper is to presents a preliminary study concerning the influence of some preparation conditions on the stability of vegetable oil-in-water (O/W emulsions as eco-friendly lubricants stabilized by nonionic surfactant. In this context, vegetable oil-in-water emulsions characteristics where assessed using microscopically observation and zeta potential. In addition, the color of these emulsions can be evaluated. It can be observed that the emulsions tend to stabilize in time.

  9. Tumor vascularity evaluated by transrectal color Doppler US in predicting therapy outcome for low-lying rectal cancer

    International Nuclear Information System (INIS)

    Barbaro, Brunella; Valentini, Vincenzo; Coco, Claudio; Mancini, Anna Paola; Gambacorta, Maria Antonietta; Vecchio, Fabio Maria; Bonomo, Lorenzo

    2005-01-01

    Purpose: To evaluate the impact on T downstaging of the vasculature supplying blood flow to rectal cancer evaluated by color Doppler ultrasound. Methods and Materials: Color Doppler images were graded in 29 T3-staged rectal carcinoma patients sonographically just before chemoradiation. Any arterial vessels detected in rectal masses were assigned one of two grades: vascularity was considered as grade 1 for vessels feeding the periphery and as grade 2 for vessels coursing in all rectal masses within its peripheral and central portions. The pulsatility indices (PI = peak systolic velocity - end-diastolic velocity/time-averaged maximum velocity) were calculated in the central and peripheral portions. Results: The pathologic observations showed a change in stage in 15 of the 23 patients graded 2, positive predictive value 65.2% (p = 0.047), and in one of the six rectal cancers graded 1 (negative predictive value, 83.3%). The minimal peripheral PI values in rectal cancer graded 2 were higher in nonresponding (2.2 ± 1.3) than in responding lesions (1.6 ± 0.7) p = 0.01. Conclusion: Vascularity graded 2 associated with low peripheral PI values are indicators of therapy outcome. Vascularity graded 1 and high peripheral PI values in graded 2 have negative predictive value

  10. Gender-related asymmetric brain vasomotor response to color stimulation: a functional transcranial Doppler spectroscopy study.

    Science.gov (United States)

    Njemanze, Philip C

    2010-11-30

    The present study was designed to examine the effects of color stimulation on cerebral blood mean flow velocity (MFV) in men and women. The study included 16 (8 men and 8 women) right-handed healthy subjects. The MFV was recorded simultaneously in both right and left middle cerebral arteries in Dark and white Light conditions, and during color (Blue, Yellow and Red) stimulations, and was analyzed using functional transcranial Doppler spectroscopy (fTCDS) technique. Color processing occurred within cortico-subcortical circuits. In men, wavelength-differencing of Yellow/Blue pairs occurred within the right hemisphere by processes of cortical long-term depression (CLTD) and subcortical long-term potentiation (SLTP). Conversely, in women, frequency-differencing of Blue/Yellow pairs occurred within the left hemisphere by processes of cortical long-term potentiation (CLTP) and subcortical long-term depression (SLTD). In both genders, there was luminance effect in the left hemisphere, while in men it was along an axis opposite (orthogonal) to that of chromatic effect, in women, it was parallel. Gender-related differences in color processing demonstrated a right hemisphere cognitive style for wavelength-differencing in men, and a left hemisphere cognitive style for frequency-differencing in women. There are potential applications of fTCDS technique, for stroke rehabilitation and monitoring of drug effects.

  11. Ecocardiografia por Doppler tecidual no diagnóstico de rejeição após transplante cardíaco Ecocardiografía con Doppler tisular en el diagnóstico de rechazo después de transplante cardíaco Tissue doppler echocardiography in the diagnosis of heart transplantation rejection

    Directory of Open Access Journals (Sweden)

    Marcos Valério Coimbra Resende

    2011-07-01

    Full Text Available FUNDAMENTO: A biópsia endomiocárdica (BEM é o método padrão-ouro para o diagnóstico de rejeição celular (RC após transplante cardíaco (TC. OBJETIVO: Testar a hipótese de que o exame de imagem por Doppler tecidual (IDT pode detectar RC > 3A e agregar informação diagnóstica, comparado ao Doppler convencional. MÉTODOS: Cinquenta e quatro pacientes com TC foram submetidos à BEM e estudo ecocardiográfico através de IDT em até 24 horas. Comparamos os pacientes com TC e RC > 3A com pacientes com TC e RC 3A em 39/129 (30,2% das BEM. O melhor preditor isolado para o diagnóstico de RC foi a a'LAT, com sensibilidade de 76,3%, especificidade de 73,8% (p = 0,001. Na análise multivariada, a a'LAT (p = 0,001, a'SEP (p = 0,002, relação e'/a' LAT (p = 0,006, relação e'Mitral/ e'LAT (p = 0,014, SINF (p = 0,009 foram preditores de RC > 3A. Obtivemos um escore com sensibilidade de 88,2%, acurácia de 79,6%, e valor preditivo negativo de 92,9% para diagnosticar RC > 3A. O Doppler convencional (fluxo mitral e pulmonar venoso não foi relevante para predizer a RC > 3A. CONCLUSÃO: O estudo de IDT agregou informação diagnóstica para predizer RC > 3A quando comparado ao Doppler convencional. O modelo baseado em IDT pode ser tornar um método em potencial para detectar RC > 3A após TC.FUNDAMENTO: La biopsia endomiocárdica (BEM es el método gold standard para el diagnóstico de rechazo celular (RC después de transplante cardíaco (TC. OBJETIVO: Testear la hipótesis de que el examen de imagen con Doppler tisular (IDT puede detectar RC > 3A y agregar información diagnóstica, comparado al Doppler convencional. MÉTODOS: Cincuenta y cuatro pacientes con TC fueron sometidos a BEM y estudio ecocardiográfico a través de IDT en hasta 24 horas. Comparamos los pacientes con TC y RC > 3A con pacientes con TC y RC 3A en 39/129 (30,2% de las BEM. El mejor predictor aislado para el diagnóstico de RC fue la a'LAT, con sensibilidad de 76

  12. Assessment of the fetomaternal circulation in threatened abortion by transvaginal color Doppler.

    Science.gov (United States)

    Kurjak, A; Zudenigo, D; Predanic, M; Kupesic, S; Funduk, B

    1994-01-01

    Transvaginal color Doppler was used to investigate blood flow in the fetomaternal circulation of 60 women with threatened abortion and 90 women with normal intrauterine pregnancy. The obtained Doppler sonograms were analyzed and the resistance index (RI) was calculated in the maternal circulation, while in the fetal circulation the pulsatility index (PI) was used. There was no significant difference in the RI values of the maternal circulation between women with normal pregnancies and pregnancies complicated by bleeding, but with normal pregnancy outcome (p > 0.05). No differences in RI values of the uterine, arcuate and radial arteries were found between pregnancies with threatened abortion and normal pregnancy outcome and women with abnormal outcome (p > 0.05). In 9 of 21 women with visible retrochorionic hematoma, the RI of the spiral arteries was higher on the hematoma side in comparison to the opposite side (p abortion, the RI of the spiral arteries was lower in comparison to the control group. Such findings could be caused by the vasodilatating products of inflammation which probably exist in such areas. There was no significant difference in terms of the PI of fetal blood vessels between normal pregnancy and threatened abortions with normal outcome, as well as between threatened abortions with normal outcome and subsequent abortions of live fetuses (p > 0.05).

  13. Riesgo de ictus isquémico en niños con Sβ talasemia. Estudio con Doppler transcraneal Risks of ischemic stroke in children suffering Sβ-thalassemia. Transcranial Doppler study

    Directory of Open Access Journals (Sweden)

    Claudio Enrique Scherle-Matamoros

    2012-06-01

    Full Text Available En niños con anemia por células falciformes, el riesgo de ictus isquémico varía según el genotipo de la hemoglobinopatía. En estos casos, la determinación de la velocidad de flujo sanguíneo mediante Doppler transcraneal (DTC puede predecir la ocurrencia de isquemia cerebral. Con el objetivo de describir las características del DTC en la Sβ talasemia, se estudiaron 32 enfermos menores de 18 años atendidos en el Instituto de Hematología e Inmunología y remitidos para su evaluación con ultrasonido. La edad media de los niños fue de 10,5 años. Se estudió la misma cantidad de enfermos con cada genotipo Sβ; solamente en un paciente la ventana temporal no fue útil. En el 97 % de los enfermos la velocidad media de flujo en las arterias cerebrales medias era inferior a 170 cm/s y solo en un niño estaban en el rango del grupo condicional. Se registraron asimetrías interhemisféricas en la velocidad media de flujo de las arterias cerebrales anteriores en el 29 % de los casos; en el 19,6 % en las arterias cerebrales medias; y en el 6,4 % en las carótidas internas extracraneales. Los niveles más altos de velocidad media de flujo se registraron en los enfermos con Sβ0 talasemia y en las arterias cerebrales medias. Existió una correlación inversa entre la edad y los niveles de hemoglobina con la velocidad de flujo de los 3 vasos estudiados. El riesgo de ictus isquémico en la Sβ talasemia es bajo, sin diferencia entre los 2 genotipos evaluados.In children with sickle cell anemia, the risk of ischemic stroke varies according to genotype of hemoglobinopathy. In these cases, determining the velocity of blood flow by transcranial Doppler (TCD can predict the occurrence of cerebral ischemia. In order to describe the characteristics of DTC in Sβ thalassemia, we studied 32 patients younger than 18 treated at the Institute of Hematology and Immunology, who were referred for ultrasound assessment. The age rate of children was 10.5 years old

  14. Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD-CT angiography

    International Nuclear Information System (INIS)

    Clevert, D.A.; Johnson, T.; Flach, P.M.; Strautz, T.I.; Becker, C.; Reiser, M.; Jung, E.M.; Ritter, G.; Gallegos, M.T.; Kubale, R.

    2007-01-01

    The purpose of this study is to investigate the diagnostic potential of color-coded Doppler sonography (CCDS), power-Doppler (PD) and B-flow ultrasound in assessing the degree of extracranial internal carotid artery (ICA) stenosis in comparison to CT-angiography (MD-CTA). Thirty-two consecutive patients referred for CTA with 41 ICA-stenoses were included in this prospective study. MD-CTA was performed using a 64 row scanner with a CTDIvol of 13.1 mGy/cm. In CTA, CCDS, PD and B-flow, the degree of stenosis was evaluated by the minimal intrastenotic diameter in comparison to the poststenotic diameter. Two radiologists performed a quantitative evaluation of the stenoses in consensus blinded to the results of ultrasound. These were correlated to CTA, CCDS, PD and B-flow, intraoperative findings and clinical follow-up. Grading of the stenoses in B-flow ultrasound outperformed the other techniques in terms of accuracy with a correlation coefficient to CTA of 0.88, while PD and CCDS measurements yield coefficients of 0.74 and 0.70. Bland-Altman analysis additionally shows a very little bias of the three US methods between 0.5 and 3.2 %. There is excellent correlation (coefficient 0.88, CI 0.77-0.93) with 64-MD-CTA and B-flow ultrasound in terms of accuracy for intrastenotic and poststenotic diameter. Duplex sonography is useful for screening purposes. (orig.)

  15. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  16. Mitral valve coaptation and its relationship to late diastolic flow: A color Doppler and vector flow map echocardiographic study in normal subjects.

    Science.gov (United States)

    Sherrid, Mark V; Kushner, Josef; Yang, Georgiana; Ro, Richard

    2017-04-01

    Three competing theories about the mechanism of mitral coaptation in normal subjects were evaluated by color Doppler and vector flow mapping (VFM): (1) beginning of ventricular (LV) ejection, (2) "breaking of the jet" of diastolic LV inflow, and (3) returning diastolic vortices impacting the leaflets on their LV surfaces. We analyzed 80 color Doppler frames and 320 VFM measurements. In all 20 normal subjects, coaptation occurred before LV ejection, 78±16 ms before onset. On color Doppler frames the larger anterior, and smaller posterior vortices circle back and, in all cases, strike the ventricular surfaces of the leaflets. On the first closing-begins frame, for the first time, vortex velocity normal to the ventricular surface of the anterior leaflet (AML) is greater than that in the mitral orifice, and the angle of attack of LV vortical flow onto the AML is twice as high as the angle of flow onto the valve in orifice. Thus, at the moment coaptation begins, vortical flow strikes the mitral leaflet with higher velocity, and higher angle of attack than orifice flow, and thus with greater force. According to the "breaking of the jet" theory, one would expect to see de novo LV flow perpendicular to the leaflets beginning after transmitral flow terminates. Instead, the returning continuous LV vortical flow that impacts the valve builds continuously after the P-wave. Late diastolic vortices strike the ventricular surfaces of the mitral leaflets and contribute to valve coaptation, permitted by concomitant decline in transmitral flow. © 2017, Wiley Periodicals, Inc.

  17. “Focal thyroid inferno” on color Doppler ultrasonography: A specific feature of focal Hashimoto's thyroiditis

    International Nuclear Information System (INIS)

    Fu, Xianshui; Guo, Limei; Zhang, Huabin; Ran, Weiqiang; Fu, Peng; Li, Zhiqiang; Chen, Wen; Jiang, Ling; Wang, Jinrui; Jia, Jianwen

    2012-01-01

    Purpose: To evaluate color-Doppler features predictive of focal Hashimoto's thyroiditis. Materials and methods: A total of 521 patients with 561 thyroid nodules that underwent surgeries or gun biopsies were included in this study. These nodules were divided into three groups: focal Hashimoto's thyroiditis (104 nodules in 101 patients), benignity other than focal Hashimoto's thyroiditis (73 nodules in 70 patients), and malignancy (358 nodules in 350 patients). On color Doppler sonography, four vascularity types were determined as: hypovascularity, marked internal flow, marked peripheral flow and focal thyroid inferno. The χ 2 test was performed to seek the potential vascularity type with the predictive ability of certain thyroid pathology. Furthermore, the gray-scale features of each nodule were also studied. Results: The vascularity type I (hypovascularity) was more often seen in focal Hashimoto's thyroiditis than other benignity and malignancy (46% vs. 20.5% and 19%). While the type II (marked internal flow) showed the opposite tendency (26.9% [focal Hashimoto's thyroiditis] vs. 45.2% [other benignity] and 52.8% [malignancy]). However, type III (marked peripheral flow) was unable to predict any thyroid pathology. Importantly, type IV (focal thyroid inferno) was exclusive to focal Hashimoto's thyroiditis. All 8 type IV nodules appeared to be solid, hypoechoic, and well-defined. Using “focal thyroid inferno” as an indicator of FHT, the diagnostic sensitivity and specificity were 7.7% and 100% respectively. Conclusions: The vascularity type of “focal thyroid inferno” is specific for focal Hashimoto thyroiditis. Recognition of this particular feature may avoid unnecessary interventional procedures for some solid hypoechoic thyroid nodules suspicious of malignancy.

  18. A comparison of cell-free placental messenger ribonucleic acid and color Doppler ultrasound for the prediction of placental invasion in patients with placenta accreta

    OpenAIRE

    Naghshineh, Elham; Khorvash, Elahe; Kamali, Sara

    2015-01-01

    Background: The aim of the present study was to comparison between cell-free placental messenger ribonucleic acid (mRNA) and Doppler ultrasound for the prediction of placental invasion in women with placenta accreta. Materials and Methods: In this cross-sectional study, 50 pregnant women at risk for placenta accreta underwent color Doppler and assessment of cell-free placental mRNA. Real-time reverse-transcription polymerase chain reaction was used for measurement of cell-free placental m...

  19. Associations between abnormal ultrasound color Doppler measures and tendon pain symptoms in badminton players during a season: a prospective cohort study.

    Science.gov (United States)

    Boesen, Anders Ploug; Boesen, Morten Ilum; Torp-Pedersen, Soren; Christensen, Robin; Boesen, Lars; Hölmich, Per; Nielsen, Michael Bachmann; Koenig, Merete Juhl; Hartkopp, Andreas; Ellegaard, Karen; Bliddal, Henning; Langberg, Henning

    2012-03-01

    Color Doppler ultrasound is widely used to examine intratendinous flow in individuals with overuse tendon problems, but the association between color Doppler and pain is still unclear. Intratendinous flow is present and associated with pain in badminton players, and intratendinous flow and pain increase during a badminton season. Cohort study (prognosis); Level of evidence, 2. Ninety-five semiprofessional badminton players were included in the study at a tournament at the start of the badminton season. All players were interviewed regarding pain. The anterior knee tendons and Achilles tendons were studied. Each tendon was scored using a quantitative grading system (grades 0-5) and a qualitative scoring system (color fraction) using color Doppler ultrasound. Eight months later, 86 of the players (91%) were retested by the same investigators during an equivalent badminton tournament (including 1032 tendon regions; 86 players with 4 tendons each with 3 regions), thus forming the study group. At the start of the season, 24 players (28%) experienced pain in 37 tendons (11%), and at the end of the season, 31 players (36%) experienced pain in 51 tendons (15%), which was a statistically significant increase (P = .0002). Abnormal flow was found in 230 tendon regions in 71 players (83%) at the start of the season compared with 78 tendon regions in 41 players (48%) at the follow-up. The decrease in abnormal flow was statistically significant (P < .0001). Of the 37 painful tendons at the start of the season, 25 had abnormal flow (68%). In contrast, 131 tendons (85%) with abnormal flow at the start of the season were pain free. At the end of the season, 18 of the 51 painful tendons (35%) had abnormal flow. Ninety-six of the 131 pain-free tendons (73%) with abnormal flow at the start of the season were normalized (no pain and normal flow) at the end of the season. It was not possible to verify any association between intratendinous flow and pain at the start of the season or at

  20. Endoscopic Color Doppler Ultrasonographic Evaluation of GastricVarices Secondary to Left-Sided Portal Hypertension

    Science.gov (United States)

    Sato, Takahiro; Yamazaki, Katsu; Kimura, Mutsuumi; Toyota, Jouji; Karino, Yoshiyasu

    2014-01-01

    Gastric varices that arise secondary to the splenic vein occlusion can result in gastrointestinal hemorrhaging. Endoscopic color Doppler ultrasonography (ECDUS) was performed in 16 patients with gastric varices secondary to splenic vein occlusion. This study retrospectively evaluated the role of ECDUS in the diagnosis of gastric varices secondary to splenic vein occlusion. Thirteen patients had co-existing pancreatic diseases: 8 with chronic pancreatitis, 4 with cancer of the pancreatic body or tail and 1 with severe acute pancreatitis. Of the remaining 3 patients, 1 had myeloproliferative disease, 1 had advanced gastric cancer, and the third had splenic vein occlusion due to an obscure cause. The endoscopic findings of gastric varices were: variceal form (F) classified as enlarged tortuous (F2) in 12 cases and large, coil-shaped (F3) in 4 cases, and positive for erosion or red color sign of the variceal surface in 4 cases and negative in 12 cases. ECDUS color flow images of gastric variceal flow clearly depicted a round fundal region at the center, with varices expanding to the curvatura ventriculi major of the gastric body in all 16 cases. The velocities of F3 type gastric varices were significantly higher than those of the F2 type. The wall thickness of varices positive for erosion or red color sign was significantly less than the negative cases. I conclude that ECDUS color flow images of gastric variceal flow depicted specific findings of gastric varices secondary to splenic vein occlusion at the round fundal region at the center, with varices expanding to the curvatura ventriculi major of the gastric body. PMID:26852679

  1. Evaluation the index of ophthalmic arteries in diabetic patients with retinopathy compared to diabetic patients without retinopathy using color Doppler ultrasound

    Directory of Open Access Journals (Sweden)

    Mohammad Ghasem Hanafi

    2016-12-01

    Full Text Available Diabetic retinopathy is the most common eye complication in diabetic patients that early detection of this complication is essential. The aim of this study was to evaluate ophthalmic artery index in diabetic retinopathy by Doppler ultrasound. . In this cross-sectional study, 64 patients were studied in 4 groups (healthy, diabetic without retinopathy, background retinopathy and proliferative retinopathy. Resistance index (RI and Pulsatile Index (PI were assessed by color Doppler ultrasound. The obtained data were analyzed by ANOVA and chi-square test and ROC curve. RI in diabetic patients with proliferative retinopathy has the highest mean (0.83 and the lowest mean was observed in healthy subjects (0.54 (P <0.001 as well as in PI, the highest rate was in diabetic patients with proliferative retinopathy (1.41 and the lowest was in healthy subjects (0.92 (P <0.001. The results of our study showed that the sensitivity, specificity, positive and negative predictive values and overall accuracy of RI and PI in diabetic patients with proliferative retinopathy in the best cut-off points (0.645 and 1.0175 respectively were 100%.Ophthalmic artery index RI and PI was significantly increased in patients with diabetic retinopathy and the sensitivity and specificity for detection retinopathy was 100%. Color Doppler ultrasound method is more efficient for screening diabetic patients with retinopathy.

  2. Color Doppler imaging of the retrobulbar circulation in progressive glaucoma optic neuropathy.

    Science.gov (United States)

    Magureanu, Marineta; Stanila, Adriana; Bunescu, Liviu Valentin; Armeanu, Cristina

    2016-01-01

    It is known that elevated intraocular pressure (IOP) is the primary risk factor for glaucoma. Recently, more and more evidences have shown that the vascular deficit also plays an important role in the pathogenesis and progressions of glaucomatous optic neuropathy. This issue is backed up by glaucomatous optic neuropathy (GON) cases drug compensated in which the progression of the disease in one or both eyes is ascertained despite a normal and relatively constant IOP. The present study evaluated the hemodynamic parameters in the retrobulbar circulation in patients with progressive glaucomatous optic neuropathy in one eye, who received compensated medication. The hemodynamic parameters (PSV, EDV, IR) were measured by using color Doppler ultrasound and progression was evaluated by a repeated automated perimetry. The obtained values were statistically analyzed and compared with those obtained for the stable eye.

  3. Ratio of left ventricular peak E-wave velocity to flow propagation velocity assessed by color M-mode Doppler echocardiography in first myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Seward, J B

    2000-01-01

    OBJECTIVES: To determine the ability of the ratio of peak E-wave velocity to flow propagation velocity (E/Vp) measured with color M-mode Doppler echocardiography to predict in-hospital heart failure and cardiac mortality in an unselected consecutive population with first myocardial infarction (MI...

  4. Doppler ultrasound imaging techniques for assessment of synovial inflammation

    Directory of Open Access Journals (Sweden)

    Filippucci E

    2013-09-01

    Full Text Available Emilio Filippucci,1 Fausto Salaffi,1 Marina Carotti,2 Walter Grassi1 1Rheumatology Department, Polytechnic University of the Marche, Ancona, Italy; 2Department of Radiology, Polytechnic University of the Marche, Ancona, Italy Abstract: Ultrasound is an evolving technique, and the rapid progress made in ultrasound technology over the past ten years has dramatically increased its range of applications in rheumatology. One of the most exciting advances is the use of Doppler ultrasound imaging in the assessment of blood flow abnormalities at the synovial tissue level in patients with chronic inflammatory arthritis. This review describes the Doppler techniques available and their main applications in patients with inflammatory arthritis, discusses the evidence supporting their use, and outlines the latest advances in hardware and software. Spectral, color, and power Doppler allow sensitive assessment of vascular abnormalities at the synovial tissue level. Use of contrast agents enhances visualization of the small synovial vessels using color or power Doppler ultrasound and allows for accurate characterization of the rheumatoid pannus. Doppler techniques represent a unique method for assessment of synovial inflammation, showing blood flow characteristics in real time. They are safe, noninvasive, cost-effective, and have high sensitivity in revealing and monitoring synovitis. However, several questions still need to be answered. In the near future, the Doppler techniques described here, together with upcoming hardware and software facilities, will be investigated further and a consensus will be reached on their feasibility and appropriate use in daily rheumatologic practice. Keywords: power and color Doppler techniques, ultrasound, contrast media, synovitis, rheumatoid arthritis

  5. Color Doppler US of normal cerebral venous sinuses in neonates: a comparison with MR venography

    International Nuclear Information System (INIS)

    Miller, Elka; Daneman, Alan; Doria, Andrea S.; Blaser, Susan; Traubici, Jeffrey; Jarrin, Jose; Shroff, Manohar; Moineddin, Rahim; Moore, Aideen

    2012-01-01

    Color Doppler US (CDUS) has been used for evaluation of cerebral venous sinuses in neonates. However, there is very limited information available regarding the appearance of superficial and deep normal cerebral venous sinuses using CDUS and the specificity of the technique to rule out disease. To determine the specificity, inter-modality and inter-reader agreement of color Doppler US (CDUS). To evaluate normal cerebral venous sinuses in neonates in comparison to MR venography (MRV). Newborns undergoing a clinically indicated brain MRI were prospectively evaluated. All underwent a dedicated CDUS of the cerebral venous sinuses within 10 h (mean, 3.5 h, range, and 2-7.6 h) of the MRI study using a standard protocol. Fifty consecutive neonates participated in the study (30 males [60%]; 25-41 weeks old; mean, 37 weeks). The mean time interval between the date of birth and the CDUS study was 19.1 days. No cases showed evidence of thrombosis. Overall agreement for US reading was 97% (range, 82-100%), for MRV reading, 99% (range, 96-100%) and for intermodality, 100% (range, 96-100%). Excellent US-MRI agreement was noted for superior sagittal sinus, cerebral veins, straight sinus, torcular Herophili, sigmoid sinus, superior jugular veins (94-98%) and transverse sinuses (82-86%). In 10 cases (20%), MRV showed flow gaps whereas normal flow was demonstrated with US. Visualization of the inferior sagittal sinus was limited with both imaging techniques. Excellent reading agreement was noted for US, MRV and intermodality. CDUS is highly specific to rule out cerebral venous thrombosis in neonates and holds potential for clinical application as part of clinical-laboratory-imaging algorithms of pre/post-test probabilities of disease. (orig.)

  6. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  7. [Ultrasound and color Doppler applications in nephrology. The normal kidney: anatomy, vessels and congenital anomalies].

    Science.gov (United States)

    Meola, Mario; Petrucci, Ilaria; Giovannini, Lisa; Samoni, Sara; Dellafiore, Carolina

    2012-01-01

    Gray-scale ultrasound is the diagnostic technique of choice in patients with suspected or known renal disease. Knowledge of the normal and abnormal sonographic morphology of the kidney and urinary tract is essential for a successful diagnosis. Conventional sonography must always be complemented by Doppler sampling of the principal arterial and venous vessels. B-mode scanning is performed with the patient in supine, prone or side position. The kidney can be imaged by the anterior, lateral or posterior approach using coronal, transverse and oblique scanning planes. Morphological parameters that must be evaluated are the coronal diameter, the parenchymal thickness and echogenicity, the structure and state of the urinary tract, and the presence of congenital anomalies that may mimic a pseudomass. The main renal artery and the hilar-intraparenchymal branches of the arterial and venous vessels should be accurately evaluated using color Doppler. Measurement of intraparenchymal resistance indices (IP, IR) provides an indirect and quantitative parameter of the stiffness and eutrophic or dystrophic remodeling of the intrarenal microvasculature. These parameters differ depending on age, diabetic and hypertensive disease, chronic renal glomerular disease, and interstitial, vascular and obstructive nephropathy.

  8. Renal venous thrombosis in an infant with predisposing thrombotic factors: color Doppler ultrasound and MR evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Argyropoulou, Maria I.; Papadopoulou, Frederica; Nikolopoulos, Pangiotis [Department of Radiology, Medical School, University of Ioannina, 45110, Ioannina (Greece); Giapros, Vassilios I.; Drougia, Aikaterini A.; Andronikou, Styliani [Neonatology Clinic, Medical School, University of Ioannina, 45110, Ioannina (Greece); Vartholomatos, Georgios A. [Department of Haematology, Medical School, University of Ioannina, 45110, Ioannina (Greece)

    2003-08-01

    We report a case of a neonate with hereditary thrombophilia presenting with renal venous thrombosis (RVT). Early color Doppler findings of RVT were lacking venous flow, and the arterial diastolic flow was reversed. This very high-resistance arterial flow is for the first time described in neonatal RVT. Magnetic resonance imaging showed low signal intensity of the renal pyramids on T1- and T2-weighted images, suggesting acute hemorrhage. After intravenous contrast injection, persistent cortical enhancement was observed along with lack of medullary enhancement. Despite the progressive reestablishment of some venous drainage, the kidney showed atrophy and loss of function. (orig.)

  9. Renal venous thrombosis in an infant with predisposing thrombotic factors: color Doppler ultrasound and MR evaluation

    International Nuclear Information System (INIS)

    Argyropoulou, Maria I.; Papadopoulou, Frederica; Nikolopoulos, Pangiotis; Giapros, Vassilios I.; Drougia, Aikaterini A.; Andronikou, Styliani; Vartholomatos, Georgios A.

    2003-01-01

    We report a case of a neonate with hereditary thrombophilia presenting with renal venous thrombosis (RVT). Early color Doppler findings of RVT were lacking venous flow, and the arterial diastolic flow was reversed. This very high-resistance arterial flow is for the first time described in neonatal RVT. Magnetic resonance imaging showed low signal intensity of the renal pyramids on T1- and T2-weighted images, suggesting acute hemorrhage. After intravenous contrast injection, persistent cortical enhancement was observed along with lack of medullary enhancement. Despite the progressive reestablishment of some venous drainage, the kidney showed atrophy and loss of function. (orig.)

  10. Absence of Doppler signal in transcranial color-coded ultrasonography may be confirmatory for brain death: A case report

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Topçuoğlu

    2015-08-01

    Full Text Available Transcranial Doppler ultrasonography (TCD is a valuable tool for demonstrating cerebral circulatory arrest (CCA in the setting of brain death. Complete reversal of diastolic flow (to-and-fro flow and systolic spikes in bilateral terminal internal carotid arteries and vertebrobasilar circulation are considered as specific sonogram configurations supporting the diagnosis of CCA. Because of the possibility of sonic bone window impermeability, absence of any waveform in TCD is not confirmatory for CCA unless there is documentation of disappearance of a previously well detected signal by the same recording settings. Transcranial color-coded sonography (TCCS with B-mode imaging can reliably detect adequacy of bone windows with clarity contralateral skull and ipsilateral planum temporale visualization. Therefore, absence of detectable intracranial Doppler signal along with available ultrasound window in TCCS can confirm clinical diagnosis of brain death. We herein discuss this entity from the frame of a representative case.

  11. Printing of cotton with eco-friendly, red algal pigment from Gracilaria sp.

    Science.gov (United States)

    Moldovan, S.; Ferrandiz, M.; Franco, E.; Mira, E.; Capablanca, L.; Bonet, Mª

    2017-10-01

    Natural dyes represent an emerging trend in the textile industry and eco-fashion due to the increasing awareness of the sustainability concept, which must be applied to the surrounding environment. In the light of the stated problem, the search for alternative sources of dyes, revealed the new, eco-friendly, biodegradable, non-carcinogenic and sustainable colorant matter, the algal biomass. In the present work, the suitability and viability of printing cotton fabrics with pigments obtained from the red macroalgae Gracilaria sp., has been investigated. For this aim, phycoerythrin, the red pigment, was extracted from fresh algal biomass, and used in a laboratory pigment-printing process, employing a natural and synthetic printing paste, for process efficiency comparison. The color values and the rubbing and laundering fastness of the printed substrates were evaluated. Results show that a light pink color can be obtained when applying both tested printing processes, and in terms of color fastness, both printing pastes show good behavior. In conclusion, the algal pigments show a high printing capacity on cotton substrates, either when employing the synthetic conventional paste and; moreover, when applying the more sustainable and eco-friendly natural paste.

  12. Diagnostic accuracy of color Doppler flow imaging and Duplex US in peripheral arterial disease

    International Nuclear Information System (INIS)

    Karmel, M.I.; Polak, J.F.; Whittemore, A.D.; Mannick, J.A.; Donaldson, M.C.; O'Leary, D.H.

    1988-01-01

    Color Doppler flow imaging (5 MHz) and Duplex US were used in a prospective examination of 154 arterial segments in the lower extremities of 11 symptomatic patients. Each extremity was divided into seven arterial segments (common femoral, profunda femoral, proximal, middle, and distal superficial femoral, and proximal and distal popliteal arteries). Arterial maps were drawn for each patient and compared with the arteriograms. Seventeen significant stenoses and 18 complete occlusions were predicted and confirmed by means of arteriography. Four significant stenoses and four occlusions were predicted and not confirmed. One hundred nine normal arterial segments were correctly predicted. No significant stenoses or occlusions were missed. Prospective identification of the severity and location of disease can help to optimize both the angiographic approach and hospital services utilization

  13. B-mode for thyroid nodule characterization at 7.5 MHz versus 13 MHz; Attualita' dell'ecografia nel modo B nella caratterizzazione delle malattie nodulari tiroidee: studio ecografiaco di confronto con sonde da 7.5 e da 13 MHz

    Energy Technology Data Exchange (ETDEWEB)

    Amodio, F.; Carbone, M.; Rossi, E.; Brunese, L.; Vallone, G. [Neaples Univ., Neaples (Italy). Dipt. di Scienze Biomorfologiche, Ist. di Scienze Radiologiche; Pisano, G.; Iorio, S. [Neaples Univ., Neaples (Italy). Dipt. di Scienze Biomorfologiche, Sez. di Anatomia Patologica e Citopatologica; Benincasa, G. [Neaples Univ., Neaples (Italy). Dipt. di Scienze Biomorfologiche, Ist. di Endocrinologia, Medicina Interna e Malattie della Nutrizione

    1999-09-01

    The paper investigates B-mode ultrasonography capabilities in diagnosis and characterizing thyroid nodules and compared the personal experience findings with those of few analytical studies in the literature. It is also compared the diagnostic accuracy of conventional 7.5 MHz versus more recent 13 MHz transducers. [Italian] Lo studio presenta i dati sull'accuratezza diagnostica dell'ecografia nel modo B con trasduttore da 7.5 MHz con quella di un trasduttore di piu' recente commercializzazione da 13 MHz. E' una tappa fondamentale nell'iter diagnostico del nodulo tiroideo, se integrata con lo studio qualitativo (color e power Doppler) e semiquantitativo (Doppler pulsato) della vascolarizzazione nodulare.

  14. Granulomatous Prostatitis: Gray-scale Transrectal Ultrasonography and Color Doppler Ultrasonography Findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Jung; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae; Kim, Eui Jong [Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2007-12-15

    We report here three cases of granulomatous prostatitis. All cases were confirmed by a transrectal ultrasonography (TRUS)-guided core biopsy of the prostate. Two cases received intravesical BCG therapy for a bladder tumor, and one case had no known predisposing condition. Gray-scale TRUS showed low echoic nodules in the outer gland in all cases. Color Doppler ultrasonography (CDUS) showed several dot-like blood flows within the low echoic nodules in two cases and several dot-like blood flows and short linear blood flows within the low echoic nodules in one case. Gray-scale TRUS findings of granulomatous prostatitis are similar to findings of prostate cancer. On CDUS, several dot-like blood flows or short linear blood flows were noted within the low echoic nodules in patients with granulomatous prostatitis. If low echoic nodules with dot-like or short linear blood flows are noted in patients with genitourinary tract tuberculosis or previous BCG therapy, granulomatous prostatitis should be included in the differential diagnosis. However, a prostatic biopsy is required for a final diagnosis

  15. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    International Nuclear Information System (INIS)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo; Kim, Jung Sik

    2002-01-01

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  16. [Elective lymph node dissection in malignant melanoma--status of color Doppler findings].

    Science.gov (United States)

    Omlor, G; Dill-Müller, D; Gross, G; Kautz, G; Schüder, G; Zaun, H; Feifel, G

    1996-01-01

    Since there is still a controversial discussion about the ELND in melanoma patients, the purpose of this prospective study was to optimize the indication concerning ELND by ultrasound examinations. 144 patients with primary melanomas were checked every 3 months after excision. Echomorphologic pattern and intranodal vascularisation in the color-flow Doppler modus provide essential information for differential diagnosis. We found 47 patients (32.6%) with suspicious ultrasound lesions. 50% of these patients had no pathological clinical findings, the histological findings of excised lymph nodes were positive in all cases. It must be emphasized, however, that the group with lymph node metastases included 12 patients with low-risk-melanomas (2 x Tis, 10 x T1 historical control group (141 patients), where ELND was performed routinely in high-risk-patients ( > T2), the incidence of ELND in our hospital decreased more than 50%; at the same time the percentage of detected lymph node metastases increased (twice).

  17. Relationship between hemodynamic changes of portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis

    Directory of Open Access Journals (Sweden)

    CHENG Xiaofei

    2014-11-01

    Full Text Available ObjectiveTo explore the relationship between hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis. MethodsA total of 192 patients with hepatitis B cirrhosis who were admitted to our hospital from March 2010 to December 2013, as well as 100 healthy persons, were recruited. The mean portal vein blood flow velocity (PVVmean, hepatic artery pulsatility index (HAPI, and hepatic artery resistance index (HARI were measured by color Doppler ultrasound. FibroScan was also carried out. All data were statistically analyzed using SPSS 13.0. Continuous data were expressed as mean±SD and compared between groups by t-test. ResultsThe HAPI, HARI, and FibroScan value of the patient group were 1.56±024, 0.73±0.05, and 25.38±7.73, respectively, significantly higher than those of the control group (1.36±0.14, 0.65±0.07, and 7.8±3.6 (P<0.05; the PVVmean of the patient group was 14.43±1.86, significantly lower than that of the control group (17.35±0.56 (P<0.05. FibroScan value was positively correlated with HAPI and HARI (r1=0.59, r2=0.66, P<0.001, but negatively correlated with PVVmean (r=-0.64, P<0.001. ConclusionThe liver stiffness assessed by FibroScan and the hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound are vitally important for evaluating the severity of liver cirrhosis.

  18. Arteritis de células gigantes (Arteritis temporal Utilidad del Eco-Doppler Color en el diagnóstico

    Directory of Open Access Journals (Sweden)

    Hugo Tarigo

    2016-09-01

    El objetivo de la presente comunicación es reafirmar la utilidad y valor de este método diagnóstico, subutilizado en nuestra práctica clínica, en pacientes con planteo de arteritis de células gigantes.

  19. The use of the color Doppler ultrasonography in the diagnosis and monitoring of an atypical case of giant-cell arteritis

    Directory of Open Access Journals (Sweden)

    Nádia Martins

    2016-04-01

    Full Text Available Giant Cell Arteritis (GCA is a large vessels vasculitis that is typically characterised by headache, scalp tenderness, jaw claudication and visual disturbances. Temporal arteries color Doppler ultrasonography (CDUS is a sensitive and non-invasive image technique used in the diagnosis of this disease. This work highlights the importance of CDUS in the diagnostic workup of GCA and also demonstrates it´s usefullness in the evaluation and documentation of the response to corticosteroids therapy in an atypical case of ACG.

  20. The use of the color Doppler ultrasonography in the diagnosis and monitoring of an atypical case of giant-cell arteritis.

    Science.gov (United States)

    Martins, N; Polido-Pereira, J; Rodrigues, A M; Soares, F; Batista, P; Pereira da Silva, J A

    2016-01-01

    Giant Cell Arteritis (GCA) is a large vessels vasculitis that is typically characterised by headache, scalp tenderness, jaw claudication and visual disturbances. Temporal arteries color Doppler ultrasonography (CDUS) is a sensitive and non-invasive image technique used in the diagnosis of this disease. This work highlights the importance of CDUS in the diagnostic workup of GCA and also demonstrates it´s usefullness in the evaluation and documentation of the response to corticosteroids therapy in an atypical case of ACG.

  1. EL PROYECTO EUROPEO ECO. ROMPIENDO BARRERAS EN EL ACCESO AL CONOCIMIENTO

    Directory of Open Access Journals (Sweden)

    Sara Osuna-Acedo

    2017-01-01

    Full Text Available El Proyecto europeo ECO ( E-learning, Communication, Open-Data busca desarrollar un modelo educativo horizontal y bidireccional, desde la nueva realidad de los MOOC. Con base en los principios de equidad, inclusi n so - cial, accesibilidad, autonom a y apertura, el empoderamiento del alumnado se hace realidad con esta propuesta de formaci n, rompiendo las barreras del escenario digital del curso para repercutir, desde las redes sociales, en la capa social. Tomando como referente el impulso formativo de los MOOC de ECO, los resultados que se presentan en este estudio han sido analizados desde una metodolog a cuantitativa optando por el an lisis, como muestra intencional, de los datos obtenidos en la primera convocatoria de cursos. Se ha optado por este tipo de an lisis para identi car los rasgos que han caracterizado a este modelo formativo, la demanda que ha obtenido y su desarrollo a nivel pedag gico. Como podremos comprobar, este estudio ha dejado patente que ECO ha potenciado de forma masiva los MOOC haci n - dose presente, no solo en el mbito europeo, sino tambi n en otros pa ses, especialmente en aquellos que est n en v as de desarrollo. Esta oferta forma - tiva se ha implementado con xito en el mbito docente con la nalidad de fomentar el descubrimiento de recursos abiertos y estrategias para la mejora de la calidad educativa, ofreciendo la posibilidad de crear sus propios cursos como medio para compartir sus conocimientos con otros docentes. Como consecuencia, el xito de los MOOC y la publicitaci n de los mismos vienen determinados por la experiencia, la conformidad con los contenidos y por el grado de satisfacci n del alumnado participante, convirti ndose en publi - cista de los mismos en sus diferentes espacios sociales. El Proyecto europeo ECO se presenta como modelo de formaci n accesible que permite, no solo el dise o universal, sino tambi n la apertura y la participaci n en esta for - maci n para toda la ciudadan a.

  2. Demonstration of blood flow by color doppler in the femoral artery distal to arterial cannula during peripheral venoarterial-extracorporeal membrane oxygenation

    Directory of Open Access Journals (Sweden)

    K G Suresh Rao

    2017-01-01

    Full Text Available In spite of distal perfusion of the limb using a cannula, the limb can have ischemic events if there is an undetected kink or clot anywhere in the line or thrombus in the artery. There are several ways to monitor and assess the limb ischemia. Monitoring for clinical signs of limb ischemia like temperature change and pallor is reliable and mandatory. We report a method where we used color Doppler to document the blood flow. Curvilinear vascular probe of an echo machine is used to identify the flow in the distal femoral artery of the lower limb. . As we have demonstrated in the video attached, once flow to the distal limb perfusion system is shut off by closing the three way stop cock, we can appreciate the immediate cessation of flow in the artery by Doppler.

  3. Determination of testicular blood flow in camelids using vascular casting and color pulsed-wave Doppler ultrasonography.

    Science.gov (United States)

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  4. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    Directory of Open Access Journals (Sweden)

    Michelle Kutzler

    2011-01-01

    Full Text Available We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV was higher in fertile males compared to infertile males (P=0.0004. In addition, end diastolic velocity (EDV within the supratesticular arteries was higher for fertile males when compared to infertile males (P=0.0325. Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P=0.0104. However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P=0.121. In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P=0.486 and marginal arteries (P=0.144. The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  5. Falso seudoaneurisma del ventrículo izquierdo

    Directory of Open Access Journals (Sweden)

    Silvio Acevedo

    2007-01-01

    Full Text Available El ventrículo izquierdo puede presentar abultamientos patológicos, que se denominan aneurisma, seudoaneurisma o divertículo. Los aneurismas son los más frecuentes y su etiología más común es la enfermedad coronaria.Presentamos un paciente de 16 años, derivado al Hospital Escuela de Corrientes con diagnóstico de accidente cerebrovascular. Por eco-Doppler color, resonancia magnética y cinecoronariografía se diagnosticó seudoaneurisma ventricular izquierdo. El examen histológico demostró la presencia de fibras musculares cardíacas, por lo que se concluyó que se trataba de un aneurisma ventricular izquierdo. Esta discordancia entre el diagnóstico por imágenes y la anatomía patológica fue descripta por Mackenzie con el nombre de falso seudoaneurisma.

  6. 'Focal thyroid inferno' on color Doppler ultrasonography: A specific feature of focal Hashimoto's thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Xianshui, E-mail: fuxs1968@163.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Guo, Limei, E-mail: guolimei@bjmu.edu.cn [Department of Pathology, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Zhang, Huabin, E-mail: huabinzhang@bjmu.edu.cn [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Ran, Weiqiang, E-mail: ranwq-sina@vip.sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Fu, Peng, E-mail: fupeng01@gmail.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Li, Zhiqiang, E-mail: lizhq126@126.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Chen, Wen, E-mail: wendy7989@sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Jiang, Ling, E-mail: papayaling@yahoo.com.cn [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Wang, Jinrui, E-mail: jinrui_wang@sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Jia, Jianwen, E-mail: drjia88@sohu.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China)

    2012-11-15

    Purpose: To evaluate color-Doppler features predictive of focal Hashimoto's thyroiditis. Materials and methods: A total of 521 patients with 561 thyroid nodules that underwent surgeries or gun biopsies were included in this study. These nodules were divided into three groups: focal Hashimoto's thyroiditis (104 nodules in 101 patients), benignity other than focal Hashimoto's thyroiditis (73 nodules in 70 patients), and malignancy (358 nodules in 350 patients). On color Doppler sonography, four vascularity types were determined as: hypovascularity, marked internal flow, marked peripheral flow and focal thyroid inferno. The {chi}{sup 2} test was performed to seek the potential vascularity type with the predictive ability of certain thyroid pathology. Furthermore, the gray-scale features of each nodule were also studied. Results: The vascularity type I (hypovascularity) was more often seen in focal Hashimoto's thyroiditis than other benignity and malignancy (46% vs. 20.5% and 19%). While the type II (marked internal flow) showed the opposite tendency (26.9% [focal Hashimoto's thyroiditis] vs. 45.2% [other benignity] and 52.8% [malignancy]). However, type III (marked peripheral flow) was unable to predict any thyroid pathology. Importantly, type IV (focal thyroid inferno) was exclusive to focal Hashimoto's thyroiditis. All 8 type IV nodules appeared to be solid, hypoechoic, and well-defined. Using 'focal thyroid inferno' as an indicator of FHT, the diagnostic sensitivity and specificity were 7.7% and 100% respectively. Conclusions: The vascularity type of 'focal thyroid inferno' is specific for focal Hashimoto thyroiditis. Recognition of this particular feature may avoid unnecessary interventional procedures for some solid hypoechoic thyroid nodules suspicious of malignancy.

  7. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2012-01-01

    The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA), and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US) with Doppler in diagnosis...

  8. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Maulik, D.

    2005-01-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  9. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Maulik, D. [Winthrop Univ. Hospital, Mineola, NY (United States). Dept. of Obstetrics and Gynecology; Zalud, I. (eds.) [Kapiolani Medical Center for Women and Children, Honolulu, HI (United States)

    2005-07-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  10. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  11. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  12. Tenosinovitis flexora piógena de la mano: hallazgos ecográficos Pyogenic flexor tenosynovitis of the hand: sonographic findings

    Directory of Open Access Journals (Sweden)

    A. Rodríguez

    2007-09-01

    Full Text Available Los autores describen los hallazgos ecográficos en tres pacientes con tenosinovitis flexora piógena (TFP de la mano. Los hallazgos patológicos encontrados en el Eco-Doppler Color fueron un halo hipoecogénico peritendinoso y una hipervascularización de la vaina sinovial. La Ecografía es un procedimiento no invasivo que permite diagnosticar de manera eficiente y precoz la TFP y permite además realizar un estadiaje preoperatorio siendo una guía útil para planificar la cirugía en función de la cantidad y localización de la colección purulenta y de la integridad tendinosa.The authours describe the sonographic findings in three cases of pyogenic flexor tenosynovitis of the hand. Hipoechogenic peritendinous area and hipervascularization of the synovial sheath revealed as the pathologic findings. In Color Doppler US Ultrasound is a non-invasive procedure that allows to make an accurate and early diagnosis of pyogenic flexor tenosynovitis, it is an useful guide for planning surgery taking account the amount and localization of the purulence and the integrity of the tendons.

  13. Airborne Doppler Wind Lidar Post Data Processing Software DAPS-LV

    Science.gov (United States)

    Beyon, Jeffrey Y. (Inventor); Koch, Grady J. (Inventor); Kavaya, Michael J. (Inventor)

    2015-01-01

    Systems, methods, and devices of the present invention enable post processing of airborne Doppler wind LIDAR data. In an embodiment, airborne Doppler wind LIDAR data software written in LabVIEW may be provided and may run two versions of different airborne wind profiling algorithms. A first algorithm may be the Airborne Wind Profiling Algorithm for Doppler Wind LIDAR ("APOLO") using airborne wind LIDAR data from two orthogonal directions to estimate wind parameters, and a second algorithm may be a five direction based method using pseudo inverse functions to estimate wind parameters. The various embodiments may enable wind profiles to be compared using different algorithms, may enable wind profile data for long haul color displays to be generated, may display long haul color displays, and/or may enable archiving of data at user-selectable altitudes over a long observation period for data distribution and population.

  14. [Postpartal ovarian thrombophlebitis. Value of Doppler ultrasonograph y].

    Science.gov (United States)

    Renaud-Giono, A; Giraud, J R; Poulain, P; Proudhon, J F; Grall, J Y; Moquet, P Y; Darnault, J P

    1996-01-01

    Thrombophlebitis of the ovarian vein is a well recognized but uncommon complication during the postpartum period. We report a small series and emphasize the contribution of color Doppler and the basic therapeutic measures.

  15. Eco-friendly dentistry: Need of future. An overview

    Directory of Open Access Journals (Sweden)

    Savy Arora

    2017-01-01

    Full Text Available In today's world, it is very necessary to understand the importance of being eco-friendly in every facet of our lives. The color “green” has healing power and denotes renewal, growth, and hope. “Eco-friendly dentistry” attempts to reduce the detrimental impact of dental practices on the environment and promote environmental awareness and sustainability to patients. This paper attempts to cover all possible aspects of making a dental practice eco-friendly, both in a dental perspective as well as a general perspective. While establishing an eco-friendly dental workplace, the dentist needs to assess his choices in planning the infrastructure and purchasing of equipment and dental materials. Eco-friendly dentistry is a newly evolving practice of dentistry, which encompasses a simultaneous devotion to sustainability, prevention, precaution, and a minimally invasive patient-centric, as well as global-centric treatment. There are two main avenues for implementing eco-friendly dentistry: (1 appropriate policy development and implementation and (2 dentists taking responsibility/ownership in the absence of policies and regulations. Although in some cases, it may take a little extra effort or money; dentists throughout the world are doing their best to reduce the environmental impact of the dental practice. Although the commitment of one small dental office cannot save the planet, certainly, the collective efforts of many small offices as well as large dental hospitals/colleges can ensure that dentists, at least, will not be responsible for destroying it. This article discusses various factors that can be incorporated into dental practice that can help make dentistry eco-friendly.

  16. Comparison of brucella and non-specific epididymorchitis: gray scale and color Doppler ultrasonographic features

    International Nuclear Information System (INIS)

    Ozturk, Adil; Ozturk, Ebru; Zeyrek, Fadile; Onur, Kahraman; Sirmatel, Ocal; Kat, Nurcan

    2005-01-01

    Objective: The aim of this study is to find out if it is possible to differentiate between brucellar and non-specific epididymorchitis by comparing ultrasonography (US) and color Doppler ultrasonography (CDUS) findings. Material and methods: Fifty-six patients diagnosed to have epididymorchitis both clinically and ultrasonographically were included to study. All of the patients were investigated serologically for brucella. Twenty-eight of those patients were admitted brucella epididymorchitis because of high agglutinations titers for brucella. The other 28 patients were admitted non-specific epididymorchitis because of normal agglutinations titers for brucella. Testicular size, echogenicity, hydrocele, internal echoes and/or septations within hydrocele, and scrotal skin thickness of normal and involved testis were compared by ultrasonography. Besides, pick systolic velocity, end diastolic velocity, resistive index and pick systolic velocity ratio values were measured by bilateral testicular color Doppler ultrasonography in both groups. When the p-value is <0.05, the difference between groups is accepted as statistically significant. Results: Thickening of scrotal skin was seen in 17 of 28 patients with brucella epididymorchitis (BEPO) (67%) and in 25 of 28 patients with non-specific epididymorchitis (NEPO) (89.2%) (p < 0.01). There was no difference between groups regarding presence of hydrocele. However hydrocele seen in all patients was anechoic except for two patients (8.6%). Hydrocele seen in 18 of 22 patients with BEPO and hydrocele had internal echogenicity or septation (p < 0.001). Sizes of testes and epididymis were found to be increased in involved testis compared to normal testis. Testes of all patients with NEPO were homogenous with decreased echogenicity except for five patients (17.8%). However, 23 patients with BEPO (82%) found to have heterogenous testis (p < 0.001). Spectral measurements showed increased PSV and EDV values and decreased RI values in

  17. Comparison of brucella and non-specific epididymorchitis: gray scale and color Doppler ultrasonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Ozturk, Adil [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey)]. E-mail: ozturka26@hotmail.com; Ozturk, Ebru [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey); Zeyrek, Fadile [Department of Microbiology, Harran University School of Medicine, Sanliurfa (Turkey); Onur, Kahraman [Department of Urology, SSK Sanliurfa Hastanesi, Sanliurfa (Turkey); Sirmatel, Ocal [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey); Kat, Nurcan [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey)

    2005-11-01

    Objective: The aim of this study is to find out if it is possible to differentiate between brucellar and non-specific epididymorchitis by comparing ultrasonography (US) and color Doppler ultrasonography (CDUS) findings. Material and methods: Fifty-six patients diagnosed to have epididymorchitis both clinically and ultrasonographically were included to study. All of the patients were investigated serologically for brucella. Twenty-eight of those patients were admitted brucella epididymorchitis because of high agglutinations titers for brucella. The other 28 patients were admitted non-specific epididymorchitis because of normal agglutinations titers for brucella. Testicular size, echogenicity, hydrocele, internal echoes and/or septations within hydrocele, and scrotal skin thickness of normal and involved testis were compared by ultrasonography. Besides, pick systolic velocity, end diastolic velocity, resistive index and pick systolic velocity ratio values were measured by bilateral testicular color Doppler ultrasonography in both groups. When the p-value is <0.05, the difference between groups is accepted as statistically significant. Results: Thickening of scrotal skin was seen in 17 of 28 patients with brucella epididymorchitis (BEPO) (67%) and in 25 of 28 patients with non-specific epididymorchitis (NEPO) (89.2%) (p < 0.01). There was no difference between groups regarding presence of hydrocele. However hydrocele seen in all patients was anechoic except for two patients (8.6%). Hydrocele seen in 18 of 22 patients with BEPO and hydrocele had internal echogenicity or septation (p < 0.001). Sizes of testes and epididymis were found to be increased in involved testis compared to normal testis. Testes of all patients with NEPO were homogenous with decreased echogenicity except for five patients (17.8%). However, 23 patients with BEPO (82%) found to have heterogenous testis (p < 0.001). Spectral measurements showed increased PSV and EDV values and decreased RI values in

  18. Standardization of the first-trimester fetal cardiac examination using spatiotemporal image correlation with tomographic ultrasound and color Doppler imaging.

    Science.gov (United States)

    Turan, S; Turan, O M; Ty-Torredes, K; Harman, C R; Baschat, A A

    2009-06-01

    The challenges of the first-trimester examination of the fetal heart may in part be overcome by technical advances in three-dimensional (3D) ultrasound techniques. Our aim was to standardize the first-trimester 3D imaging approach to the cardiac examination to provide the most consistent and accurate display of anatomy. Low-risk women with normal findings on first-trimester screening at 11 to 13 + 6 weeks had cardiac ultrasound using the following sequence: (1) identification of the four-chamber view; (2) four-dimensional (4D) volume acquisition with spatiotemporal image correlation (STIC) and color Doppler imaging (angle = 20 degrees, sweep 10 s); (3) offline, tomographic ultrasound imaging (TUI) analysis with standardized starting plane (four-chamber view), slice number and thickness; (4) assessment of fetal cardiac anatomy (four-chamber view, cardiac axis, size and symmetry, atrioventricular valves, great arteries and descending aorta) with and without color Doppler. 107 consecutive women (age, 16-42 years, body mass index 17.2-50.2 kg/m(2)) were studied. A minimum of three 3D volumes were obtained for each patient, transabdominally in 91.6%. Fetal motion artifact required acquisition of more than three volumes in 20%. The median time for TUI offline analysis was 100 (range, 60-240) s. Individual anatomic landmarks were identified in 89.7-99.1%. Visualization of all structures in one panel was observed in 91 patients (85%). Starting from a simple two-dimensional cardiac landmark-the four-chamber view-the standardized STIC-TUI technique enables detailed segmental cardiac evaluation of the normal fetal heart in the first trimester. (c) 2009 ISUOG.

  19. Nutcracker Syndrome Accompanying Pelvic Congestion Syndrome; Color Doppler Sonography and Multislice CT Findings: A Case Report

    International Nuclear Information System (INIS)

    Inal, Mikail; Karadeniz Bilgili, Mihrace Yasemin; Sahin, Safa

    2014-01-01

    Nutcracker syndrome (NCS) is a rare pathology, caused by compression of the left renal vein (LRV) between the abdominal aorta (AA) and the superior mesenteric artery (SMA), due to reduction of the angle between AA and SMA. This leads to LRV varices, left gonadal vein varices and therefore, the pelvic congestion syndrome. For this reason, coexistence of NCS and pelvic congestion syndrome has been described. It manifests by hematuria, proteinuria, and nonspecific pelvic pain secondary to pelvic congestion, dyspareunia and persistent genital arousal. We report a 27-year-old woman who experienced hematuria and left flank pain. The diagnosis of NCS accompanied by pelvic congestion syndrome was missed initially, but later on the diagnosis was made by color Doppler ultrasound, abdominal computed tomography (CT) and CT angiography that were later performed. She refused interventional and surgical treatments, and was lost to follow up

  20. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo [Keimyung University School of Medicine, Taegu (Korea, Republic of); Kim, Jung Sik [Radiological Clinic, Taegu (Korea, Republic of)

    2002-06-15

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  1. Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study.

    Science.gov (United States)

    Zuhur, Sayid Shafi; Ozel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Cil, Esra; Altuntas, Yüksel

    2012-01-01

    To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.

  2. Analisa Eco-friendly Attitudes Dan Eco-friendly Behavior Terhadap Eco-friendly Intention Green Hotel Di Indonesia

    OpenAIRE

    Silvia, Lanny; Rudijanto, Diana Gabriela; Kristanti, Monika

    2017-01-01

    Kesadaran masyarakat akan lingkungan yang semakin meningkat membuat masyarakat gencar mencari hotel yang ramah lingkungan dibandingkan dengan hotel konvensional. Penelitian ini bertujuan untuk mengetahui perbedaan eco-friendly attitude, eco- friendly behavior, dan eco-friendly intention konsumen generasi x dan generasi y terhadap green hotel di Indonesia dan apakah eco-friendly attitudes dan eco-friendly behavior berpengaruh signifikan terhadap eco-friendly intention. Total responden dalam pe...

  3. A Product Line Analysis for Eco-Designed Fashion Products: Evidence from an Outdoor Sportswear Brand

    Directory of Open Access Journals (Sweden)

    Luo Wang

    2017-07-01

    Full Text Available With the increasing awareness of sustainability, eco-design has been an important trend in the fashion industry. Many fashion brands such as Nike, Adidas, and The North Face have developed sustainable fashion by incorporating eco-design elements. Eco-design is an important part of sustainable supply chains. In this paper, we conducted a product line analysis of eco-designed products from a famous outdoor sportswear brand, Patagonia. We collected Patagonia’s 2017 Spring Season product line data and analyzed the data through descriptive analysis, factor analysis and correlation analysis. We found that Patagonia mainly uses organic, recycled, and traceable materials in their eco-product line development. We identified that the usage of eco-materials may significantly affect the number of color choices and product weight as well as gender difference, pattern design, product fit and online reviewers’ opinions at Patagonia. We argued that Patagonia should focus on functionality more than aesthetics in eco-design. We discussed how sustainable fashion firms should manage eco-design in the supply chain.

  4. The role of Doppler ultrasonography in the evaluation of the renal function

    International Nuclear Information System (INIS)

    Krasteva, R.; Kiperova, B.; Andreev, E.; Kostadinova, I.; Petrov, T.; Hadjidekov, V.; Simeonova, A.

    2008-01-01

    The purpose of the study was to evaluate Doppler ultrasonography in the detection of the renal function. Sixty six patients with unilateral kidney changes were enrolled in this prospective study. 16 had hypoplastic kidney, 24 had hypofunctioned kidney and 26 had afunctioned kidney. 15 healthy potential donors were controls. A dynamic renal scintigraphy was performed with 74-111 MBq 99mTc-MAG3. The Color, Pulsed and Power Doppler were performed. The Vp and δVp derived from the spectrum of the segmental arteries were measured during Pulsed Doppler examination. There are not any difference between kidneys of health and hypoplastic kidneys on color and Power Doppler. The hypofunctioning kidneys had reduced blood flow and afunctioning kidneys had markedly reduced blood flow. The Vp of donors (48.8±7.6) and Vp of hypoplastic kidneys (49.9±4.8) were significantly higher compared to Vp of hypofunctioning kidneys (31.6±10.0) and to Vp of afunctioning kidneys (26.6±9.1), (p 14.5 cm/s in 93%, and from hypofunctioning kidney by delta Vp>10.5 cm/s in 87%. The Doppler ultrasonography is very useful in the evaluation of renal function. The changes of the Doppler parameters accurately marked the loss of function which can not be detected by elevation of the creatinine level. (authors)

  5. Synchronized epiaortic two-dimensional and color Doppler echocardiographic guidance enables routine ascending aortic cannulation in type A acute aortic dissection.

    Science.gov (United States)

    Inoue, Yoshito; Takahashi, Ryuichi; Ueda, Toshihiko; Yozu, Ryohei

    2011-02-01

    Preference for arterial inflow during surgery for type A acute aortic dissection remains controversial. Antegrade central perfusion prevents malperfusion and retrograde embolism, and the ascending aorta provides arterial access for rapid establishment of systemic perfusion, especially if there is hemodynamic instability. It has not been used routinely, however, because of the disruption caused to the aorta. We evaluated the safety and efficacy of routine cannulation of the dissected aorta for the repair of type A dissection. Surgical results were analyzed for 83 consecutive patients with type A acute aortic dissection between 2002 and 2009. They were treated surgically by prosthetic graft replacement under hypothermic circulatory arrest. The ascending aorta was routinely cannulated using the Seldinger technique with epiaortic echocardiographic guidance; antegrade systemic perfusion was evaluated by color Doppler ultrasound. Systemic antegrade perfusion via the dissected ascending aorta was performed safely in all cases. There was no malperfusion or thromboembolism as a result of ascending aortic cannulation. Epiaortic 2-dimensional and color Doppler imaging provided real-time monitoring adequate for the placement and for proper systemic perfusion. There were 5 in-hospital deaths (5/83=6.0%) and 8 strokes (preoperative 6/83=7.2%, postoperative 2/83=2.4%). A total of 78 patients (78/83=94%) were discharged and have been followed up without major adverse cardiac events for a mean duration of 31.8 months. Ascending aortic cannulation is a simple and safe technique that provides a rapid and reliable route of antegrade central systemic perfusion in type A aortic dissection. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  6. Eco-anthropological Considerations on Terroir Reflexiones desde la eco-antropología sobre el terroir

    Directory of Open Access Journals (Sweden)

    Frédéric Duhart

    2011-01-01

    Full Text Available Terroir currently constitutes a key concept in the thought about the production of quality foods and drinks. In this text, we consider this notion from an eco-anthropological point of view, relying on examples taken from the past and present of certain wines. We successively study the construction of this notion, its uses (especially in the framework of denomination of origin processes and its representations.El Terroir constituye en la actualidad un concepto clave en el pensamiento sobre la producción de alimentos y de bebidas de calidad. En este texto, consideramos esta noción con un punto de vista eco-antropológico apoyándonos sobre ejemplos sacados principalmente de la historia y de la actualidad de ciertos vinos. Estudiamos sucesivamente su construcción, sus usos (en particular en el marco de los procesos de denominación de origen y sus representaciones.

  7. Ultrasonography and color Doppler of proximal gluteal enthesitis in juvenile idiopathic arthritis: a descriptive study

    Directory of Open Access Journals (Sweden)

    Thomsen Carsten

    2011-08-01

    Full Text Available Abstract Background The presence of enthesitis (insertional inflammation in patients with juvenile idiopathic arthritis (JIA is difficult to establish clinically and may influence classification and treatment of the disease. We used ultrasonography (US and color Doppler (CD imaging to detect enthesitis at the small and deep-seated proximal insertion of the gluteus medius fascia on the posterior iliac crest where clinical diagnosis is difficult. The findings in JIA patients were compared with those obtained in healthy controls and with the patients' MRI results. Methods Seventy-six proximal gluteus medius insertions were studied clinically (tenderness to palpation of the posterior iliac crest and by US and CD (echogenicity, thickness, hyperemia in 38 patients with JIA and in 38 healthy controls, respectively (median age 13 years, range 7-18 years. In addition, an additional MRI examination of the sacroiliac joints and iliac crests was performed in all patients. Results In patients with focal, palpable tenderness, US detected decreased echogenicity of the entheses in 53% of the iliac crests (bilateral in 37% and unilateral in 32%. US also revealed significantly thicker entheses in JIA patients compared to healthy controls (p Conclusions According to US, the gluteus medius insertion was thicker in JIA patients than in controls, and it was hypoechoic (enthesitis in about half of the patients. These findings may represent chronic, inactive disease in some of the patients, because there was only limited Doppler flow and MRI contrast enhancement. The present study indicates that US can be useful as an adjunct to clinical examination for improved assessment of enthesitis in JIA. This may influence disease classification, ambition to treat, and choice of treatment regimen.

  8. Relaciones entre el tamaño del pelo, el color de la piel y mucosas externas con la producción lechera en condiciones tropicales

    Directory of Open Access Journals (Sweden)

    Manrique P. Luis Phanor

    1995-06-01

    Full Text Available

    El objetivo de la investigación fue determinar las relaciones entre el tamaño del pelo, el color de la piel y el de las mucosas externas (hocico y párpados con los rendimientos productivos de vacas lecheras Lucerna, explotadas en condiciones de clima tropical en Bugalagrande, Colombia. Se utilizaron 1855 registros con datos en 180 y 305 días de lactación, producción total de leche y la duración de los períodos de lactancia. A las vacas se les asignó una de las tres categorías para el tamaño del pelo, una de las cuatro para el color de la piel y una de las tres para el color de las mucosas externas. Por medio del método de cuadrados mínimos se realizaron los respectivos análisis de varianza y con el apoyo de pruebas de medias, se demostró que el tamaño del pelo no fue una fuente de variación significativa, pero las mayores producciones se presentaron en el grupo de vacas con pelo corto o fino. La relación entre el color de la piel y los rendimientos productivos determinó diferencias estadísticas (P < 0.05 en los grupos de animales, donde las mayores producciones se presentaron en los de las vacas con piel negra y café clara. El color de las mucosas externas no influyó significativamente en los rendimientos de las vacas lecheras.

    This research was conducted to find out the relationship among hair size, skin color and externals mucosa color (muzzle and evedil occular with milk production in cows of Lucerna's race, developed under tropical condition in Bugalagrande, Colombia. A total of 1855 records were analized in 180 and 305 days of milking, total production and lactation length. Each cow was classified under one of three categories for hair size, one of four categories for skin color and one of three categories for externals mucosa color. Harvey's statistical methods were used to analyse the data and the results showed up that the size of the hair was not a source of significative variation, but the larger milk

  9. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok [Dongkang Hospital, Ulsan (Korea, Republic of); Lee, Yeong Hwan [Taegu Catholic Univ. School of Medicine, Taegu (Korea, Republic of)

    1996-06-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm.

  10. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    International Nuclear Information System (INIS)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok; Lee, Yeong Hwan

    1996-01-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm

  11. LOS ECO BUSINESS: EL PRESENTE Y FUTURO DE LOS NEGOCIOS INTERNACIONALES

    Directory of Open Access Journals (Sweden)

    Jorge Enrique Rodríguez Guevara

    2013-06-01

    Full Text Available El artículo busca describir lo que son los eco negocios en la actualidad, y su potencial en los mercados futuros. Para esta propuesta se desarrollan tres objetivos específicos: el primero iniciando con contextualizar los eco negocios y su importancia en el entorno global; el segundo, identificar experiencias significativas en los eco negocios internacionales, una mirada desde las tendencias de la oferta global, y desde las tendencias del comportamiento del consumidor. Un tercer objetivo, ilustrar la necesidad del comercio justo en la economía internacional, y la identificación de organizaciones que la promueven; por último, conclusiones y recomendaciones que permitan ampliar el análisis de los negocios internacionales y su tendencia.

  12. Colaboración con empresa de tasaciones

    OpenAIRE

    CASTILLO MORCILLO, JUAN

    2011-01-01

    Convenios con empresas de tasaciones y valoraciones. El objeto del proyecto es conseguir aprender y dominar el proceso de valoración de los distintos tipos de inmuebles urbanos mediante el cumplimiento de la Orden ministerial ECO/805/2003 Castillo Morcillo, J. (2011). Colaboración con empresa de tasaciones. http://hdl.handle.net/10251/11933. Archivo delegado

  13. Tagetes erecta mediated phytosynthesis of silver nanoparticles: an eco-friendly approach

    Directory of Open Access Journals (Sweden)

    ANIKET K. GADE

    2012-11-01

    Full Text Available Dhuldhaj UP, Deshmukh SD, Gade AK, Yashpal M, Rai MK. 2012. Tagetes erecta mediated phytosynthesis of silver nanoparticles:an eco-friendly approach. Nusantara Bioscience 4: 109-112. Nanotechnology is a multidisciplinary field having applications in the various fields like medicine, pharmacy, engineering and biotechnology. An important step in nanotechnology is to develop simple and eco-friendly method for the nanomaterial synthesis. Here we describe simple and eco-friendly method for synthesis of silver nanoparticles by extract of Tagetes erecta plant leaves. The phytosynthesis (synthesis by plant of silver nanoparticles was detected by color change from light-green to dark-brown. Synthesis of silver nanoparticles was confirmed by UV-Vis spectrophotometry, further characterization includes nanoparticle tracking analysis system (NTA (LM20 and transmission electron microscopy (TEM. TEM analysis confirms the synthesis of the polydispersed spherical silver nanoparticles of 20-50 n

  14. Evaluation of portal hypertension in cirrhotic patients using color duplex-doppler ultrasound. Preliminary study; Evaluacion de la hipertension portal del cirrotico mediante ultrasonografia duplex-Doppler color. Estudio prliminar

    Energy Technology Data Exchange (ETDEWEB)

    Varas, M J; Torres, G; Sanllely, H [Unidad de Ecografias, Consorcio del Hospital de la Cruz Roja, L` Hospitalet de Llobregat, Barcelona (Spain)

    1996-09-01

    The objective was to compare data obtained by color duplex-Doppler ultrasound (mean velocity, flow and portal vein congestion index) in patients with chronic diffuse liver disease with and without portal hypertension (PH) (demonstrated endoscopically) with that of a healthy control group. Over a two-year period, 50 studies were performed in 10 healthy subjects (control group) with a mean age of 36 years and in 40 chronic liver disease patients (study group with a mean age of 58 years), most of whom presented alcoholic liver cirrhosis and belonged to Child-Pugh class B. They were subdivided according to endoscopic study into patients without (group 1) and with (group 2) portal hypertension. There were statistically significant differences in the diameters of splenic vein, spleen, portal vein and in the portal Vm, which decreased as the Child-Pugh score rose. When the patients without (group 1) and with (group 2) endoscopic evidence of PH (esophageal varices)were analyzed and compared, the two groups presented no statistically significant differences with respect to portal Vm, blood flow out of the liver, presence of collateral vessels, or the portal vein congestion index; the latter was significantly different in both the study group as a whole and in the patients with PH when compared with the control group. Given that this report is based on a pilot study which requires a larger sample number, we are unable to arrive at definitive conclusions. (Author) 18 refs.

  15. The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact

    Science.gov (United States)

    Simon, Julianna C.; Sapozhnikov, Oleg A.; Kreider, Wayne; Breshock, Michael; Williams, James C., Jr.; Bailey, Michael R.

    2018-01-01

    The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling; however, the hypothesis is not fully accepted because the bubbles have not been directly observed. In this paper, the micron or submicron-sized bubbles predicted by the crevice bubble hypothesis are enlarged in kidney stones of five primary compositions by exposure to acoustic rarefaction pulses or hypobaric static pressures in order to simultaneously capture their appearance by high-speed photography and ultrasound imaging. On filming stones that twinkle, consecutive rarefaction pulses from a lithotripter caused some bubbles to reproducibly grow from specific locations on the stone surface, suggesting the presence of pre-existing crevice bubbles. Hyperbaric and hypobaric static pressures were found to modify the twinkling artifact; however, the simple expectation that hyperbaric exposures reduce and hypobaric pressures increase twinkling by shrinking and enlarging bubbles, respectively, largely held for rough-surfaced stones but was inadequate for smoother stones. Twinkling was found to increase or decrease in response to elevated static pressure on smooth stones, perhaps because of the compression of internal voids. These results support the crevice bubble hypothesis of twinkling and suggest the kidney stone crevices that give rise to the twinkling phenomenon may be internal as well as external.

  16. The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact.

    Science.gov (United States)

    Simon, Julianna C; Sapozhnikov, Oleg A; Kreider, Wayne; Breshock, Michael; Williams, James C; Bailey, Michael R

    2018-01-09

    The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling; however, the hypothesis is not fully accepted because the bubbles have not been directly observed. In this paper, the micron or submicron-sized bubbles predicted by the crevice bubble hypothesis are enlarged in kidney stones of five primary compositions by exposure to acoustic rarefaction pulses or hypobaric static pressures in order to simultaneously capture their appearance by high-speed photography and ultrasound imaging. On filming stones that twinkle, consecutive rarefaction pulses from a lithotripter caused some bubbles to reproducibly grow from specific locations on the stone surface, suggesting the presence of pre-existing crevice bubbles. Hyperbaric and hypobaric static pressures were found to modify the twinkling artifact; however, the simple expectation that hyperbaric exposures reduce and hypobaric pressures increase twinkling by shrinking and enlarging bubbles, respectively, largely held for rough-surfaced stones but was inadequate for smoother stones. Twinkling was found to increase or decrease in response to elevated static pressure on smooth stones, perhaps because of the compression of internal voids. These results support the crevice bubble hypothesis of twinkling and suggest the kidney stone crevices that give rise to the twinkling phenomenon may be internal as well as external.

  17. Efecto del EcoMic® en la emergencia de plántulas de Jatropha curcas (Nota Técnica Effect of EcoMic® on the emergence of Jatropha curcas seedlings (Technical Note

    Directory of Open Access Journals (Sweden)

    Yolai Noda

    2012-12-01

    Full Text Available Con el objetivo de estudiar el efecto del EcoMic® en la emergencia de las plántulas de Jatropha curcas, se hizo una prueba de observación en el laboratorio de análisis químico de la Estación Experimental de Pastos y Forrajes «Indio Hatuey». Se usaron semillas recién cosechadas, en dos tratamientos: semillas inoculadas con EcoMic® (T1, y sin inóculo (T2, con cuatro réplicas de 100 semillas cada una. Se utilizó un diseño totalmente aleatorizado y se realizaron 15 observaciones (a los 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 y 16 días de emergencia. Las medias se compararon a través de un análisis descriptivo. El efecto del T1 fue notable durante todo el período; a partir del cuarto día se observaron 45 plántulas emergidas, lo que representó el 11,2% del total de las tratadas con este biofertilizante, y el último día del estudio había emergido el 96,2%. En el T2 no se observaron plántulas emergidas en ningún momento. Se concluye que el EcoMic® ejerció un efecto positivo en la emergencia de las plántulas de J. curcas al ser utilizado como inóculo en condiciones de laboratorio. Se recomienda realizar estudios pregerminativos para determinar la dormancia en la semilla de Jatropha, teniendo en cuenta el empleo del EcoMic® como uno de los tratamientos.In order to study the effect of EcoMic® on the emergence of Jatropha curcas seedlings, an observation test was conducted in the laboratory of chemical analysis of the Experimental Station of Pastures and Forages «Indio Hatuey». Newly-harvested seeds were used, in two treatments: seeds inoculated with EcoMic® (T1, and without inoculation (T2, with four replications of 100 seeds each. A completely randomized design was used and 15 observations were made (2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 and 16 days after emergence. The means were compared through a descriptive analysis. The effect of T1 was remarkable throughout the period; since the fourth day 45

  18. A STUDY ON FACTORS AFFECTING BUYING BEHAVIOUR OF CONSUMERS FOR ECO - FRIENDLY PRODUCTS

    OpenAIRE

    N. Anil Kumar; Dr. Mridanish Jha

    2017-01-01

    Products are not the only thing which can be eco-friendly and actions are also friendly to the environment. Several people think that eco-friendly products are only the first step, and that people who are actually dedicated to the environment also need to change their lifestyles, diminishing the quantum of resources they use by living more competently. The exploratory factor analysis shows that price, quality, value, trust and easy to use are the factors that affecting buying behaviour of con...

  19. Avaliação da anastomose de artéria torácica interna esquerda com artéria interventricular anterior pela ecodopplercardiografia Evaluation of left internal thoracic artery anastomosis with left anterior descending coronary artery by Doppler echocardiography

    Directory of Open Access Journals (Sweden)

    Adelaide Arruda

    1997-12-01

    Full Text Available OBJETIVO: Avaliar o valor do ecocardiograma Doppler(ECO transtorácico na identificação de perviabilidade da anastomose entre artéria torácica interna esquerda (ATIE e interventricular anterior, realizada pela técnica de revascularização miocárdica pela minitoracotomia sem circulação extracorpórea. MÉTODOS: Estudaram-se os primeiros 12 pacientes, consecutivos, no período de pós-operatório intra-hospitalar pelo ECO, utilizando-se transdutores de 5MHz, pela via paraesternal esquerda, preferencialmente. Foram analisadas velocidades máximas e integrais de velocidade dos componentes sistólico e diastólico das curvas espectrais de fluxo Doppler. Todos pacientes foram submetidos à cinecoronariografia, enquanto hospitalizados. RESULTADOS: O ECO foi exeqüível em 93% dos pacientes. Nos com anastomose pérvia (6/7, observou-se ao estudo Doppler amplo componente diastólico (padrão A. Naqueles com anastomose obstruída (4/4 o padrão observado foi de predomínio sistólico (padrão B (p=0,003*. CONCLUSÃO: O ECO da ATIE anastomosada com a artéria interventricular anterior, após cirurgia de revascularização miocárdica pela técnica de minitoracotomia, permitiu caracterizar precocemente, com precisão, a perviabilidade da anastomose.PURPOSE: To study the value of Doppler echocardiography as a tool for the evaluation of left internal thoracic artery graft (LITAG patency in patients who underwent coronary revascularization using minimally invasive bypass surgery without extracorporeal circulation. METHODS: The first 12 consecutive patients were studied after coronary artery bypass surgery using a 5MHz Doppler transducer. Doppler signals for the systolic and diastolic flow velocities were preferably obtained in the second intercostal space. All patients underwent coronary angiography while hospitalized. RESULTS: The exam was feasible in 93% of patients. Doppler flow pattern was predominantly diastolic (pattern A in patients with patent

  20. Renal transplant assessment with color and pulsed ultrasonography. 1st part: surgical complications

    International Nuclear Information System (INIS)

    Martin Hervas, C.; Gil de Miguel, A.

    1994-01-01

    Color duplex Doppler ultrasound (US) is a highly important technique in kidney transplantation (Tx). We have performed 304 serial explorations in 140 transplant recipients assessing the morphological aspect of the graft, possible dilatation of the urinary tract and collections. Subsequently, we used color and pulsed Doppler to study the renal vascular permeability and the parenchymal resistance, calculating the indices of resistance (RI) and systolic acceleration and the frequencies. We have compared these findings with those observed in a control group of 45 patients with normally functioning grafts and we have also compared them according to the different pathologies, with those of other diagnostic imaging techniques to identify the present role of each in the assessment of kidney transplantation. Plain US plays an important role in the detection of dilations and peri renal collections, and Doppler makes it possible to differentiate, in some cases, obstructive from non obstructive dilatation. The US features of collections are nonspecific. In pulsed Doppler US, the lymphocytes present slightly elevated RI, higher than those produced in secondary dilation, in abscess-related processes and in sub capsular collections with parenchymal compromise. Color duplex Doppler is of greatest use in the diagnosis of vascular complications of Tx, especially thrombosis, stenosis and A-V fistulas. (Author)

  1. Eco-marketing and eco-design of products

    Directory of Open Access Journals (Sweden)

    Filipović Jovan

    2007-01-01

    Full Text Available Environmental marketing (Eco-marketing, as a relatively new movement, emerged at the beginning of the 20th century, is in the growing phase of its development. Eco-labeling and other ways/types of eco-marketing are attracting more attention of consumers, since they are aware of the necessity of nature conservation and environmental protection. There has been a lot of misunderstanding and miss leadings in interpretation and substantiation of ecomarketing claims in previous period of time. One of the most concrete improvements in eco-marketing was appearance and establishment of ISO 14020 guidelines. ISO 14020 guidelines are integral part of ISO 14000 series of standards, which could be implemented in eco-marketing. At the same time, development of "green" products and marketing of "green" products, are direct positive contributions to resources reduction, environmental protection and sustainable economic development. Companies designing this kind of products can expect better position on the market, improvement of competitiveness, reduction of expenses (less raw materials, less waste, less harmful effects on the environment, raising corporate social responsibility, higher export.

  2. Primary chronic venous insufficiency of the lower extremities: preoperative color duplex Doppler ultrasound study

    International Nuclear Information System (INIS)

    Selfa, S.; Diago, T.; Ricart, M.; Chulia, R.; Martin, F.

    2000-01-01

    To asses the role of color duplex Doppler ultrasound (CDU) in the preoperative study of patients with varicose veins in lower extremities. We employed CDU to examine varicose veins in 342 lower limbs, assessing reflux in saphenous veins (SV), deep venous system (DVS) and perforating veins (PV). We analyzed the relationship between the anatomical extent of the reflux and the clinical findings. Insufficiency of the superficial venous system alone was uncommon, occurring in only 10.8% of the limbs examined. Reflux was observed in SV and PV in 48.2% of the legs. It was detected in all three systems in 29.2% of cases. The presence of reflux in more than one system and more than one value was associated with increased clinical severity. The site of venous reflux in lower extremities with varicose veins varies. Greater clinical severity is observed in the presence of more marked reflux in the DVS and PV. CDU provides anatomic and functional data on the three venous systems of the lower limbs, allowing an individualized therapeutic surgery. Preoperative localization of incompetent PV by means of CDU facilities their ligation. CDU is the technique of choice for the preoperative examination of the venous systems of patients with varicose veins. (Author)

  3. Role of Doppler US and MRI in diagnosis of placenta accreta

    Directory of Open Access Journals (Sweden)

    Manal Hamisa

    2015-09-01

    Conclusion: In conclusion, data of the present study show that the use of transabdominal color Doppler ultrasonography complemented by MRI in suspected cases improves the diagnostic accuracy in prediction of placenta accreta in patients with previous cesarean delivery.

  4. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Masoud Pezeshki Rad

    2015-01-01

    Full Text Available Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56% patients were male subjects and 18 patients (44% were female. Twenty-three (56% patients of the study population were aged 60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  5. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease.

    Science.gov (United States)

    Rad, Masoud Pezeshki; Kazemzadeh, Gholam Hosain; Ziaee, Masood; Azarkar, Ghodsieh

    2015-03-01

    Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS) were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56%) patients were male subjects and 18 patients (44%) were female. Twenty-three (56%) patients of the study population were aged 60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  6. The differential diagnosis of thyroid solid nodules by colour doppler ultrasound%甲状腺实性结节的彩超鉴别诊断

    Institute of Scientific and Technical Information of China (English)

    于立江; 张颖; 贾齐玉; 陈海霞

    2015-01-01

    目的:探讨彩超在甲状腺结节良恶性鉴别中的应用价值。方法:应用彩超对130例手术治疗的甲状腺结节患者的结节情况进行回顾分析,并与病理结果对比,以得出恶性结节的超声表现。结果:130例(148个结节)中良性结节96个,彩超诊断100个;恶性结节52个,彩超诊断48个。彩超对甲状腺良恶性结节鉴别的灵敏性为89.66%,特异性为97.96%。结论:彩超对甲状腺结节良恶性的鉴别有重要的临床价值。%Objective To evaluate the value of the color Doppler ultrasound in differentiating benign and malignant thyroid nodule. Methods 130 cases of surgical treatment of patients with thyroid nodules were retrospective analysis by the color Doppler ultrasound,and compared with pathological results,to draw the sonographic appearances of the malignant nodules. Results Pathological results of 96 nod-ules were benign in 130 patients(148 nodules),the color Doppler ultrasound examination resule showed 100 with benign nodules;Patho-logical results of 52 nodules were malignant nodules,the color Doppler ultrasound resule for 48 nodules of malignant nodules. The sensitivi-ty,specificity of the color Doppler ultrasound in differentiating benign and malignant thyroid nodule was 89. 66%,97. 96%. Conclusion the color Doppler ultrasound is a valuable method in differentiating benign and malignant thyroid nodule.

  7. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  8. Influência do eco-controle no desempenho ambiental e econômico de empresas

    Directory of Open Access Journals (Sweden)

    Ilse Maria Beuren

    2013-01-01

    Full Text Available Este estudio tiene como objetivo investigar la influencia del eco-control en el desempeño ambiental y económico de las empresas. El estudio descriptivo se realizó mediante una encuesta y un enfoque cuantitativo del problema. Un cuestionario, adaptado del estudio de Henri y Journeault (2010, fue enviado a los directores de empresas que cotizan en Bovespa y que tienen sus datos en Economática®, con la excepción de las instituciones financieras; las 106 empresas que respondieron la encuesta representan una muestra del 30%. En el análisis de los datos, los procedimientos del estudio de referencia se repitieron, mediante el uso del software Statgraphics® que sí distingue la aplicación de las correlaciones canónicas. Los resultados confirman la hipótesis de que el eco-control influye en los resultados económicos directamente a través de las influencias de desempeño ambiental. Las variables de control proporcionan una prueba más en las empresas con mayor exposición al medio ambiente, la conciencia pública, la preocupación ambiental, la presión de grupos de interés y el tamaño. Se concluye que, en las empresas estudiadas, el eco-control influyó en el rendimiento económico y medioambiental. Los resultados difieren de los obtenidos por el estudio de Henri y Journeault (2010, el cual no encontró ningún efecto directo del eco-control sobre el desempeño económico, sino sólo una influencia indirecta sobre las variables de control. Estas observaciones fomentan la literatura con ideas sobre la contribución de la contabilidad de gestión para el desarrollo sostenible.

  9. Christian Andreas Doppler--the man and his legacy.

    Science.gov (United States)

    Coman, I M

    2005-01-01

    Reminding the life and legacy of the Austrian Scientist who discovered the famous 'Doppler Effect'. C.A. Doppler was born the 29th of November 1803 in Salzburg. After studies in Linz and Vienna, he graduated in mathematics, became assistant at the University and later worked as a professor in Prague. Back to Vienna, he was appointed as professor at the Polytechnic School and --in 1850--as first director of the new Institute of Physics. C.A. Doppler did publish on magnetism, electricity, optics, and astronomy. He remains in the history of science due to the discovery presented (May 25, 1842) at the Royal Bohemian Society of Science entitled "On the colored light of the double stars and certain other stars of the heavens"; the paper described (applied to light) the shift of frequency which bears nowadays his name. The theory was later experimentally proven and--extended for any electromagnetic and acoustic waves--got myriads if applications in astronomy, physics, aviation, meteorology, and health science. Satomura in Japan (1955) published it's first ultrasound vascular application--with successive achievements in the next decades. Doppler ultrasonagraphy became the main noninvasive instrument for functional assesment of heart and vessels.

  10. EcoMark 2.0

    DEFF Research Database (Denmark)

    Guo, Chenjuan; Yang, Bin; Andersen, Ove

    2015-01-01

    Eco-routing is a simple yet effective approach to substantially reducing the environmental impact, e.g., fuel consumption and greenhouse gas (GHG) emissions, of vehicular transportation. Eco-routing relies on the ability to reliably quantify the environmental impact of vehicles as they travel...... in a spatial network. The procedure of quantifying such vehicular impact for road segments of a spatial network is called eco-weight assignment. EcoMark 2.0 proposes a general framework for eco-weight assignment to enable eco-routing. It studies the abilities of six instantaneous and five aggregated models......, and experiments for assessing the utility of the impact models in assigning eco-weights. The application of EcoMark 2.0 indicates that the instantaneous model EMIT and the aggregated model SIDRA-Running are suitable for assigning eco-weights under varying circumstances. In contrast, other instantaneous models...

  11. Spatially Resolved MR-Compatible Doppler Ultrasound: Proof of Concept for Triggering of Diagnostic Quality Cardiovascular MRI for Function and Flow Quantification at 3T.

    Science.gov (United States)

    Crowe, Lindsey Alexandra; Manasseh, Gibran; Chmielewski, Aneta; Hachulla, Anne-Lise; Speicher, Daniel; Greiser, Andreas; Muller, Hajo; de Perrot, Thomas; Vallee, Jean-Paul; Salomir, Rares

    2018-02-01

    We demonstrate the use of a magnetic-resonance (MR)-compatible ultrasound (US) imaging probe using spatially resolved Doppler for diagnostic quality cardiovascular MR imaging (MRI) as an initial step toward hybrid US/MR fetal imaging. A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional electrocardiogram (ECG) and the proposed spatially resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic "false-triggered" image was retrospectively processed using metric optimized gating (MOG). Images were scored by expert readers, and sharpness, cardiac function and aortic flow were quantified. Four-dimensional (4-D) flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p ). ECG-, Doppler-triggered, and MOG ejection fractions were equivalent (p ), with false-triggered values significantly lower (p 0.05). 4-D flow quantification gave consistent results between ECG and Doppler triggering. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible, i.e., fetal imaging.

  12. Mirador de la Qubba Mayor (Lindaraja. Armadura apeinazada de cintas con vidrios de colores

    Directory of Open Access Journals (Sweden)

    Fernández-Puertas, Antonio

    2009-12-01

    Full Text Available This work studies the only decorative wooden ceiling with coloured glass that survived in situ in Hispano- Muslim Art, in the Palace of the Riyāḍ al-Sa'īd of the Alhambra, hence its enormous importance for the History of Art.

    En este trabajo se estudia la única armadura apeinazada decorativa con vidrios de colores que ha pervivido in situ en el arte hispanomusulmán, en el palacio del Riyāḍ al-Sa'īd de la Alhambra, de ahí su enorme importancia para la Historia del Arte.

  13. A comparison of cell-free placental messenger ribonucleic acid and color Doppler ultrasound for the prediction of placental invasion in patients with placenta accreta.

    Science.gov (United States)

    Naghshineh, Elham; Khorvash, Elahe; Kamali, Sara

    2015-01-01

    The aim of the present study was to comparison between cell-free placental messenger ribonucleic acid (mRNA) and Doppler ultrasound for the prediction of placental invasion in women with placenta accreta. In this cross-sectional study, 50 pregnant women at risk for placenta accreta underwent color Doppler and assessment of cell-free placental mRNA. Real-time reverse-transcription polymerase chain reaction was used for measurement of cell-free placental mRNA in maternal plasma. Based on the findings at cesarean delivery and histological examination, patients were divided into two groups of women with and without placenta accrete. To compare of the mean of mRNA levels between the two groups we used independent t-test and to compare of the mean of age and gestational age at sonography we used Mann-Whitney test. For determination of sensitivity and specificity and the cut-off point of mRNA levels we used the receiver operating characteristic curve. A total of 50 women with a mean age of 30.24 ± 4.905 years entered the study and 12 (24%) patients were diagnosed with placenta accreta. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Doppler ultrasound were 83.3%, 78.9%, 56% and 94%, respectively. Results of our study showed if we consider a cut-off point equal to 3.325, with sensitivity and specificity of 0.917 and 0.789, respectively and the sensitivity, specificity, PPV and NPV of mRNA with were cut-off point of 3.325 were 91.7%, 78.9%, 57.9% and 96.8%, respectively. Cell-free mRNA is an acceptable, easy made, functional test with sensitivity, specificity, PPV and NPV more than Doppler ultrasound for diagnosis and prediction of incidence of placenta accrete and we recommend the use of cell-free mRNA test for diagnosis of placenta accreta.

  14. Value of sonomammography utilizing color Doppler technique in qualification of breast cancer patients for sentinel node identification

    International Nuclear Information System (INIS)

    Basta, P.; Wadowska-Jaszczynska, K.; Krysztopowicz, W.; Przybylska, P.; Wisniowski, Z.

    2007-01-01

    Sentinel node identification has become a standard procedure in the management of breast cancer. This procedure requires involvement of a multidisciplinary team and is rather costly. Ultrasonography (USG) of axillary lymph nodes is a method that gives hope for improving the quality of qualification of patients for the procedure. Eighty patients with grade I and II breast cancers underwent sentinel node identification followed by axillary lymphadenectomy. Pre-operative ultrasonography was employed to assess axillary lymph nodes, using the morphological and vascular characteristics as predictors of the presence of lymph node metastases. Sensitivity of sentinel node identification reached 89.3%, specificity - 100%, positive predictive value - 100%, negative predictive value - 93.5%, percentage of false negative results - 10.7%. Sensitivity of USG reached 68.75 %, and specificity - 70.31%. In the group of patients in whom the sentinel node was identified, the sensitivity of the method was 69.23 %, and specificity - 72.41%. Preoperative axillary lymph node ultrasonography in breast cancer patients, utilizing color Doppler technique, allows better selection of patients for sentinel node identification procedure. (author)

  15. MR imaging of multiple fibroadenoma in breast: comparison with color doppler images and histologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Yang, Ik; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Ahn, Hye Kyung [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    To understand the different signal intensities seen on contrast enhanced magnetic resonance imaging (MRI) in multiple fibroadenoma of the breast, and to compare these with color Doppler ultrasonographic (CDUS) and histologic findings. MRI (1.0 Tesla, TIWI, T2WI, 3D-gradient echo dynamic contrast enhancement study) findings of 24 histologically proven cases of fibroadenoma in five patients were evaluated and compared with the histologic components (myxoid, adenomatous, fibrous). In addition, vascular flow, as seen on CDUS and histologic section, was compared. The observed degree of signal intensity waw classified into three groups, as follows: negative, 8.3%, mild to moderate, 54.2%; marked, 37.5%. On histologic section, the greater the fibrotic component, the higher the intensity of MRI enhancement, the greater the glandular component, and the intensity. CDUS showed vascular flow in only one tumor larger than 3cm in diameter. Vascular patterns of tumors on CDUS were dots in mass and detouring pattern, but in this case and in strongly enhanced cases, tumor vascularity-as seen on histologic section-showed no significant increase. Different signal intensities seen on contrast enhanced MRI in multiple fibroadenoma of the breast may be related more to the amount of glandular and fibrotic component than to increased tumor vascularity.

  16. MR imaging of multiple fibroadenoma in breast: comparison with color doppler images and histologic findings

    International Nuclear Information System (INIS)

    Chung, Soo Young; Yang, Ik; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Ahn, Hye Kyung

    1997-01-01

    To understand the different signal intensities seen on contrast enhanced magnetic resonance imaging (MRI) in multiple fibroadenoma of the breast, and to compare these with color Doppler ultrasonographic (CDUS) and histologic findings. MRI (1.0 Tesla, TIWI, T2WI, 3D-gradient echo dynamic contrast enhancement study) findings of 24 histologically proven cases of fibroadenoma in five patients were evaluated and compared with the histologic components (myxoid, adenomatous, fibrous). In addition, vascular flow, as seen on CDUS and histologic section, was compared. The observed degree of signal intensity waw classified into three groups, as follows: negative, 8.3%, mild to moderate, 54.2%; marked, 37.5%. On histologic section, the greater the fibrotic component, the higher the intensity of MRI enhancement, the greater the glandular component, and the intensity. CDUS showed vascular flow in only one tumor larger than 3cm in diameter. Vascular patterns of tumors on CDUS were dots in mass and detouring pattern, but in this case and in strongly enhanced cases, tumor vascularity-as seen on histologic section-showed no significant increase. Different signal intensities seen on contrast enhanced MRI in multiple fibroadenoma of the breast may be related more to the amount of glandular and fibrotic component than to increased tumor vascularity

  17. Dossier Shell Eco-Marathon; Dossier Shell Eco-Marathon

    Energy Technology Data Exchange (ETDEWEB)

    Matla, P.

    2012-05-15

    Three articles address subjects concerning the annual race with highly energy efficient cars: the Shell Eco-Marathon. [Dutch] In 3 artikelen wordt aandacht besteed aan de ontwerpen voor de jaarlijkse race met superzuinige auto's, de Shell Eco-Marathon.

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Peligros asociados con los lentes de contacto de color Sep. 26, 2013 It started as an impulsive ... Halloween is a popular time for people to use colored contact lenses to enhance their costumes. From ...

  19. Study of hemodynamics of retroocular vascular by color Doppler ultrasound in diabetes%彩色多普勒超声对糖尿病眼球后血管血流动力学研究

    Institute of Scientific and Technical Information of China (English)

    雷震; 张梅; 李加平; 龙劲松

    2011-01-01

    目的:通过彩色多普勒超声观察糖尿病眼球后血管的血流动力学,研究其诊断价值.方法:共用彩色多普勒超声检查了正常人眼球、糖尿病视网膜病变(diabetic retinopathy,DR)及有糖尿病但无糖尿病视网膜病变(non-diabetic retinopathy,NDR)眼球的球后血管并与荧光素眼底血管造影及检眼镜对比.结果:随着DR的进展,糖尿病患者眼球后血管血流动力学改变的趋势是眼球后动脉的血流速度下降,阻力升高;球后静脉流速增高伴搏动性增强.结论:彩色多普勒超声技术为定量评价DR,判断其预后提供了重要的参考价值.%Objective: To observe the hemodynamic changes of retroocular and evaluate the diagnostic valuation of color Doppler ultraqound in diabetes. Methods: Retroocular hemodynamics were measured in normal and diabetic retinopathy (DR) and non-diabetic retinopathy (NDR) on color Doppler flow imagining and compared with fundus fluorescein angiography (FFA) and Ophthalmoscope. Results: In the progress of DR, the flow's decrease and the resistance's mcrease of retroocular artery were detected in this research, the increase of flow and pulsatility index of retroocular vein were observed too.Conclusion: Color Doppler ultrasound is of important reference value for not only prognosis but also quantitative analysis of diabetic retinopathy.

  20. La Democracia Líquida: exigencia de la sustentabilidad eco-política

    Directory of Open Access Journals (Sweden)

    Jorge Francisco Aguirre Sala

    2017-01-01

    Full Text Available Se pretende demostrar por qué la Democracia Líquida es exigida por la sustentabilidad necesaria a la eco-política. Las premisas de argumento son: la justicia global y la soberanía ciudadana son exigencias de la sustentabilidad eco-política y, a su vez, la Democracia Líquida es el modelo que por excelencia promueve la justicia y la soberanía. El corolario es que la Democracia Líquida es la modalidad idónea para la consolidar también al eco-desarrollo. El argumento obliga a explicar conceptos medulares: sustentabilidad, uso de recursos, sentido del consumo. Para lo cual se destacan apreciaciones axiológicas de la biosfera: desde la teología hasta la economía. A su vez, el debate sobre el consumismo se enmarca en la sustentabilidad ampliada más allá de los límites de la ecología. Todo lo anterior suma argumentos a favor de la eco-política ejercida con la Democracia Líquida como la mejor instancia para la elaboración de las políticas ambientales.

  1. Determinantes de la eco-innovación en la actividad de construcción en España

    Directory of Open Access Journals (Sweden)

    Segarra-Oña, M.

    2015-03-01

    Full Text Available Based on the authors’ validated model that identifies processes and/or products orientation and obtaining information from market sources as variables that affect eco-innovation, we classify different groups according to their eco-innovative behavior of companies belonging to the construction industry. Using the REBUS-PLS algorithm applied to 222 companies with data retrieved from PITEC database, two groups are detected, highlighting one group more oriented towards the environment when innovating, with higher levels of R&D investment and the absence of significant differences in the variables descriptive (size, turnover, investments, employees. Results indicate that eco-innovation orientation does not depend on these features but it is linked to the performance of the company. Results have important practical applications for both, public policy actions to promote eco-innovation and private actions to improve companies’ ecoinnovation behaviour.Partiendo del modelo validado por los autores que determina como variables que afectan a la eco-innovación la orientación a procesos, a productos y la obtención de información de fuentes de mercado, identificamos distintos grupos atendiendo al comportamiento eco-innovador de las empresas del sector de la construcción. Utilizando el algoritmo REBUS-PLS aplicado a 222 empresas con datos de PITEC, se detectan 2 grupos, destacando uno más orientado hacia el medioambiente al innovar, con cifras más altas de inversión en I+D así como la ausencia de diferencias significativas en las variables descriptivas (tamaño, cifra de negocios, inversiones, empleados, lo que indica que la eco-orientación al innovar no depende de estas características y sí que va ligada al comportamiento de la empresa. Los resultados tienen importantes aplicaciones prácticas por lo que a las actuaciones de política de promoción de la eco-innovación se refiere, tanto a nivel público como privado.

  2. EcoBears

    DEFF Research Database (Denmark)

    Nielsen, Nick; Pedersen, Sandra Bleuenn; Sørensen, Jens Ager

    2015-01-01

    In this paper, we introduce the EcoBears concept that aims to augment household appliances with functional and aesthetic features to promote their "use'' and "longevity of use'' to prevent their disposal. The EcoBears also aim to support the communication of environmental issues in the home setting....... We present our initial design and implementation of the EcoBears that consist of two bear modules (a mother and her cub). We also present our preliminary concept validations and lessons learned to be considered for future directions....

  3. Transient basilar artery occlusion monitored by transcranial color Doppler presenting with a spectacular shrinking deficit: a case report

    Directory of Open Access Journals (Sweden)

    Del Sette Massimo

    2010-01-01

    Full Text Available Abstract Introduction We describe the case of a 79-year-old Caucasian Italian woman with a transient basilar occlusion monitored by transcranial Doppler, with subsequent recanalization and clinical shrinking deficit. This is the first case of transient basilar occlusive disease diagnosed and monitored by transcranial Doppler. This case is important and needs to be reported because transient basilar occlusion may be easily diagnosed if transcranial Doppler is performed. Case presentation A 79-year-old woman affected by chronic atrial fibrillation and not treated with oral anticoagulants, cardioverted to sinus rhythm during a gastric endoscopy. She then showed a sudden-onset loss of consciousness, horizontal and vertical gaze palsy, tetraparesis and bilateral miosis and coma. Two hours later, the symptoms resolved quickly, leaving no residual neurologic deficits. Transcranial Doppler examination showed a dampened flow in the basilar artery in the emergency examination and a restored flow when the symptoms resolved. Conclusion This is the first case of transient basilar occlusive disease diagnosed and monitored by transcranial Doppler. We believe that transcranial Doppler should be performed in all cases of unexplained acute loss of consciousness, in particular, if associated with signs of brainstem dysfunctions.

  4. A study of the distribution of color Doppler flows in the superficial digital flexor tendon of young Thoroughbreds during their training periods.

    Science.gov (United States)

    Hatazoe, Takashi; Endo, Yoshiro; Iwamoto, Yohei; Korosue, Kenji; Kuroda, Taisuke; Inoue, Saemi; Murata, Daiki; Hobo, Seiji; Misumi, Kazuhiro

    2015-01-01

    Aim of this study was to evaluate the relationships of exercise and tendon injury with Doppler flows appearing in the superficial digital flexor tendon (SDFT) of young Thoroughbreds during training periods. The forelimb SDFTs of 24 one- to two-year-old Thoroughbreds clinically free of any orthopaedic disorders were evaluated using grey-scale (GS) and color Doppler (CD) images during two training periods between December 2013 to April 2015. Twelve horses per year were examined in December, February, and April in training periods that began in September and ended in April. The SDFT was evaluated in 3 longitudinal images of equal lengths (labelled 1, 2, 3 in order from proximal to distal), and 6 transversal images separated by equal lengths (labelled 1A, 1B, 2A, 2B, 3A and 3B in order from proximal to distal) of the metacarpus using both GS and CD. The running (canter and gallop) distance for 1 month before the date of the ultrasonographic examinations was increased in December, February, and April in both of the two training periods. CD flows defined as rhythmically blinking or pulsatory colored signals were found in 56 of 864 (6.4%) transversal CD images, in 28, 12, 13, and 3 images of 1A, 1B, 2A and 2B, respectively, and in 7, 14, and 35 images captured in December, February, and April, respectively. There were no longitudinal or transversal GS images indicating injury in the SDFTs in either of the two training periods. The increase of CD flows in the proximal regions of the SDFT are possibly related to the increase of the running distance during the training periods of the one- to two-year-old Thoroughbreds. Because no injury was diagnosed in the SDFTs by GS images during the training periods, the increase of CD flows in the proximal parts of SDFT is not necessarily predictive of tendon injury in the near future during the training period of young Thoroughbreds.

  5. Asociación del color de la concha de reproductores de Argopecten purpuratus (Lamarck, 1819 con la supervivencia, crecimiento y desarrollo larval de sus progenies Association between shell color of breeds (Lamarck, 1819 and the survival, growth and larval development of their progenies

    Directory of Open Access Journals (Sweden)

    Ricardo M García

    2012-07-01

    Full Text Available Las conchas de moluscos bivalvos marinos son extremadamente diversas en sus patrones de pigmentación y riqueza de colores. Tal diversidad se debe a factores ambientales y genéticos. En bivalvos marinos adultos, individuos con coloraciones de concha poco comunes en las poblaciones silvestres suelen presentar tasas de crecimiento y supervivencia menores que aquellos con colores de concha más frecuentes. Conociendo que la variación del color de la concha en Argopecten purpuratus está bajo control genético, en este trabajo se pone a prueba la hipótesis de que los loci responsables de dicha variación pueden afectar el crecimiento, la supervivencia y la tasa de desarrollo de las larvas de esta especie. Se estimó la supervivencia y el crecimiento en progenies de cruzamientos dirigidos entre individuos de A. purpuratus con colores de concha blanco, naranja y marrón, y se verificó la existencia de diferencias en las tasas de desarrollo. El crecimiento de las larvas producidas en cruzamientos que incluyeron individuos marrones o blancos con naranja no mostraron diferencias entre sí. En cambio, las progenies producto de autofecundaciones de individuos naranja y blancos presentaron tasas de crecimiento significativamente menores que las anteriores y distintas entre sí. Las tasas de desarrollo y de supervivencia, en cambio, no mostraron diferencias entre las progenies de los distintos tipos de cruzamientos. Los resultados sugieren que los genes que controlan la variación del color en las conchas de juveniles y adultos de A. purpuratus afectarían la tasa de crecimiento de sus larvas, pero no la tasa de desarrollo ni su supervivencia.Marine bivalve mollusks are extremely diverse in shell color and pigmentation patterns. Such diversity is affected by environmental and genetic factors. Some evidences in adult marine bivalves shows that individuals with low-frequency shell colors have lower growth rates and/or higher mortalities than those with the

  6. [Pilot study of echocardiographic studies using color- and pulsed-wave spectral Doppler methods in blue-crowned amazons (Amazona ventralis) and blue-fronted amazons (Amazona a. aestiva)].

    Science.gov (United States)

    Pees, M; Straub, J; Schumacher, J; Gompf, R; Krautwald-Junghanns, M E

    2005-02-01

    Colour-flow and pulsed-wave spectral Doppler echocardiography was performed on 6 healthy, adult Hispaniolan amazon parrots (Amazona ventralis) and 6 blue-fronted amazon parrots (Amazona a. aestiva) to establish normal reference values. Birds were anesthetized with isoflurane in oxygen and placed in dorsal recumbency. An electrocardiogram was recorded continuously and birds were imaged with a micro-phased-array scanner with a frequency of 7.0 MHz. After assessment of cardiac function in 2-D-echocardiography, blood flow across the left and the right atrioventricular valve and across the aortic valve was determined using color-flow and pulsed-wave spectral Doppler echocardiography. Diastolic inflow (mean value +/- standard deviation) into the left ventricle was 0.17 +/- 0.02 m/s (Hispaniolan amazons) and 0.18 +/- 0.03 m/s (Blue fronted amazons). Diastolic inflow into the right ventricle was 0.22 +/- 0.05 m/s (Hispaniolan amazons) and 0.22 +/- 0.04 m/s (Blue fronted amazons). Velocity across the aortic valve was 0.84 +/- 0.07 m/s (Hispaniolan amazons) and 0.83 +/- 0.08 m/s (Blue fronted amazons). Systolic pulmonary flow could not be detected in any of the birds in this study. No significant differences were evident between the two species examined. Results of this study indicate that Doppler echocardiography is a promising technique to determine blood flow in the avian heart. Further studies in other avian species are needed to establish reference values for assessment of cardiac function in diseased birds.

  7. Developing an eco-routing application.

    Science.gov (United States)

    2014-01-01

    The study develops eco-routing algorithms and investigates and quantifies the system-wide impacts of implementing an eco-routing system. Two eco-routing algorithms are developed: one based on vehicle sub-populations (ECO-Subpopulation Feedback Assign...

  8. Secuencias rápidas de Eco de Espín en imágen por resonancia magnética

    OpenAIRE

    Santa Marta Pastrana, Cristina

    2011-01-01

    Esta tesis doctoral profundiza en el estudio de las secuencias rápidas turbo espín eco para la adquisición de imagen por resonancia magnética. En particular, se centra en la caracterización de las imágenes obtenidas mediante la combinación de la secuencia turbo espín eco con la adquisición parcial de datos o Fourier parcial. Se propone un método para mejorar la resolución espacial de la imagen sin aumentar el tiempo de exploración respecto de la secuencia original turbo espín eco. Dicha mejor...

  9. Doppler-ultrasonographic finding of air in the portal vein: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ki Soon; Lee, Kwan Sup; Lee, Yul; Chung, Soo Young; Bae, Sang Hoon [College of Medicine, Hallym University, Seoul (Korea, Republic of)

    1994-03-15

    Classically air in the portal vein has been detected on plain radiography, but computed tomography and ultrasonography have been shown to be more sensitive. We report a case of air in the PV in a 10-day-old infant with pneumatosis intestinalis with its ultrasonographic and Doppler findings. The patient was a 10-day-old infant born by cesarean section at 41 weeks. Simple abdomen film revealed branching pattern of radiolucent air shadows within in contour of liver, gas distention of bowel loops and thickenod bowel walls with lincar intraluminal air shadows in abdomen, suggesting necrotizing enterocolitis. So we performed Doppler ultrasonography. Ultrasonography showed branching pattern of hyperechogenic dots and along the lumen of left portal vein. The color Doppler study revealed an aliasing duo to increased velocity and whirling pattern of blood flow, and the Duplex Doppler spectral display showed sharp, vertical bidirectional spikes by air in portal vein. Air in the portal vein can be easily diagnosed by the following signs: hyperechogenic dots in the portal vein on ultrasonography and vertical, sharp bidirectional spikes superimposed on the usual Doppler tracing of the portal vein on Duplex ultrasonography.

  10. Doppler-ultrasonographic finding of air in the portal vein: a case report

    International Nuclear Information System (INIS)

    Park, Ki Soon; Lee, Kwan Sup; Lee, Yul; Chung, Soo Young; Bae, Sang Hoon

    1994-01-01

    Classically air in the portal vein has been detected on plain radiography, but computed tomography and ultrasonography have been shown to be more sensitive. We report a case of air in the PV in a 10-day-old infant with pneumatosis intestinalis with its ultrasonographic and Doppler findings. The patient was a 10-day-old infant born by cesarean section at 41 weeks. Simple abdomen film revealed branching pattern of radiolucent air shadows within in contour of liver, gas distention of bowel loops and thickenod bowel walls with lincar intraluminal air shadows in abdomen, suggesting necrotizing enterocolitis. So we performed Doppler ultrasonography. Ultrasonography showed branching pattern of hyperechogenic dots and along the lumen of left portal vein. The color Doppler study revealed an aliasing duo to increased velocity and whirling pattern of blood flow, and the Duplex Doppler spectral display showed sharp, vertical bidirectional spikes by air in portal vein. Air in the portal vein can be easily diagnosed by the following signs: hyperechogenic dots in the portal vein on ultrasonography and vertical, sharp bidirectional spikes superimposed on the usual Doppler tracing of the portal vein on Duplex ultrasonography

  11. Correlation of Color Doppler with Multidetector CT Angiography Findings in Carotid Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Živorad N. Savic

    2010-01-01

    Full Text Available The aim of this paper was to examine the correlation between the Color Doppler ultrasound (CD-US and multidetector CT angiography (MDCTA diagnostic methods, and to define the degree and extent of stenosis in patients with internal carotid artery stenosis. This was a cross-sectional study with a consecutive series of patients. All US examinations were always carried out by the same physician-angiologist, while all CT examinations were always carried out by the same physician-radiologist. Both worked independently from each other. The stenosis area was measured at the narrowest point by NASCET criteria for US/CT. Peak systolic velocity (PSV over 210 cm/sec and end diastolic velocity (EDV over 110 cm/sec criteria were applied for stenoses with lumen narrowed over 70%, while PSV under 130 cm/sec and EDV under 100 cm/sec criteria were applied for those with lumen narrowed under 70%. A total of 124 carotid arteries were observed; namely, 89 narrowed and 68 surgically treated. All patients were reviewed by US and then by MDCTA; patients with 70–99% stenosis underwent surgery. The correlation coefficient between stenosis degree measured by US and MDCTA was 0.922; p 0.05. The US and CT matching level for stenoses from 70 to 99% was very high (κ = 0.778, p < 0.01. In conclusion, there is a highly significant statistical correlation among both diagnostic methods when measuring stenosis degree and extent. US is more dependent on the physician, while MDCTA is more objective and independent from the physician. We think it would be appropriate to undertake an MDCTA exam for those patients who are candidates for carotid endarterectomy.

  12. Modelling Of Eco-innovation Diffusion: The EU Eco-label

    Directory of Open Access Journals (Sweden)

    KIJEK TOMASZ

    2015-03-01

    Full Text Available The aim of this article is to carry out a theoretical and empirical analysis of the process of eco-label diffusion. Eco-labels allow consumers to identify products and services that have a reduced environmental impact during their life cycle. Thus, they are aimed at diminishing the information gap between sellers and buyers. The results of the estimation using the Bass model indicate that the diffusion of the EU eco-label has been most dynamic in countries such as Hungary, Poland, Denmark, Germany and France. In turn, the scope of diffusion (absolute saturation level reached the highest value for companies in France and Italy. In addition, the results of the study confirm the stimulating impact of the scope of eco-label diffusion on consumer awareness of environmental issues. This finding points to the need for environmental education among consumers, which could in turn encourage firms to undertake pro-environmental actions.

  13. EcoGene 3.0.

    Science.gov (United States)

    Zhou, Jindan; Rudd, Kenneth E

    2013-01-01

    EcoGene (http://ecogene.org) is a database and website devoted to continuously improving the structural and functional annotation of Escherichia coli K-12, one of the most well understood model organisms, represented by the MG1655(Seq) genome sequence and annotations. Major improvements to EcoGene in the past decade include (i) graphic presentations of genome map features; (ii) ability to design Boolean queries and Venn diagrams from EcoArray, EcoTopics or user-provided GeneSets; (iii) the genome-wide clone and deletion primer design tool, PrimerPairs; (iv) sequence searches using a customized EcoBLAST; (v) a Cross Reference table of synonymous gene and protein identifiers; (vi) proteome-wide indexing with GO terms; (vii) EcoTools access to >2000 complete bacterial genomes in EcoGene-RefSeq; (viii) establishment of a MySql relational database; and (ix) use of web content management systems. The biomedical literature is surveyed daily to provide citation and gene function updates. As of September 2012, the review of 37 397 abstracts and articles led to creation of 98 425 PubMed-Gene links and 5415 PubMed-Topic links. Annotation updates to Genbank U00096 are transmitted from EcoGene to NCBI. Experimental verifications include confirmation of a CTG start codon, pseudogene restoration and quality assurance of the Keio strain collection.

  14. EcoGene 3.0

    Science.gov (United States)

    Zhou, Jindan; Rudd, Kenneth E.

    2013-01-01

    EcoGene (http://ecogene.org) is a database and website devoted to continuously improving the structural and functional annotation of Escherichia coli K-12, one of the most well understood model organisms, represented by the MG1655(Seq) genome sequence and annotations. Major improvements to EcoGene in the past decade include (i) graphic presentations of genome map features; (ii) ability to design Boolean queries and Venn diagrams from EcoArray, EcoTopics or user-provided GeneSets; (iii) the genome-wide clone and deletion primer design tool, PrimerPairs; (iv) sequence searches using a customized EcoBLAST; (v) a Cross Reference table of synonymous gene and protein identifiers; (vi) proteome-wide indexing with GO terms; (vii) EcoTools access to >2000 complete bacterial genomes in EcoGene-RefSeq; (viii) establishment of a MySql relational database; and (ix) use of web content management systems. The biomedical literature is surveyed daily to provide citation and gene function updates. As of September 2012, the review of 37 397 abstracts and articles led to creation of 98 425 PubMed-Gene links and 5415 PubMed-Topic links. Annotation updates to Genbank U00096 are transmitted from EcoGene to NCBI. Experimental verifications include confirmation of a CTG start codon, pseudogene restoration and quality assurance of the Keio strain collection. PMID:23197660

  15. Uso del EcoMic® y el producto bioactivo Pectimorf® en el establecimiento de dos especies forrajeras Use of EcoMic® and the bioactive product Pectimorf® in the establishment of two forage species

    Directory of Open Access Journals (Sweden)

    Gertrudis Pentón

    2011-09-01

    Full Text Available Con el objetivo de evaluar el efecto de EcoMic®, Pectimorf® y/o su combinación en el establecimiento de las especies forrajeras Morus alba L. (morera y Sorghum bicolor L. (sorgo, se realizaron dos experimentos. El primero se hizo con M. alba, inoculada o no con HMA, y se evaluaron las variables del rendimiento y la supervivencia de las plantas a los 90 y 240 días. El experimento con S. bicolor se realizó durante 30 días a partir de la siembra, y se evaluó la germinación de las semillas y las variables del rendimiento a los 7, 15 y 30 días. Los tratamientos fueron: testigo, inoculación con HMA, imbibición en Pectimorf, y su combinación. Se empleó un diseño en bloques al azar, con tres repeticiones. Se obtuvo respuesta de la morera a la inoculación con HMA a los 90 días de establecimiento, en términos de peso verde de las raicillas y las raíces, que triplicaron los resultados del testigo. A los 240 días las plantas inoculadas duplicaron el rendimiento del testigo y no hubo diferencias significativas en la supervivencia, en el incremento de biomasa comestible por unidad de área foliar, ni en la relación del sistema asimilativo por unidad de biomasa comestible. En el sorgo, el empleo combinado del Pectimorf® y el EcoMic® produjo un aumento significativo, respecto al testigo, en la germinación de las semillas a los 30 días (89 vs 58%, la altura efectiva (4,04 vs 3,55 cm, el grosor de la base del tallo (0,18 vs 0,15 cm, el área del limbo, el número de hojas abiertas (4 vs 3 y el largo de las hojas. Se concluye que los productos EcoMic® y Pectimorf®, así como su combinación constituyen una alternativa efectiva para el establecimiento de las especies forrajeras estudiadas.In order to evaluate the effect of EcoMic®, Pectimorf® and/or their combination on the establishment of the forage species Morus alba L. (mulberry and Sorghum bicolor L. (sorghum, two trials were conducted. The first one was done with M. alba

  16. 'Eco' For Whom? Envisioning Eco-urbanism in the Sino-Singapore Tianjin Eco-city, China

    OpenAIRE

    Caprotti, Federico; Springer, Cecilia; Harmer, Nichola

    2015-01-01

    Eco-cities have attracted international attention from governments, corporations, academics and other actors seeking to use sustainable urban planning to reduce urban environmental impacts. China has devoted significant political will and economic resources to the development of new-build eco-city projects, reflecting the Chinese government's goals to build a 'harmonious society' in which environmental sustainability and social stability are mutually reinforcing. We critically analyse the cas...

  17. Conjugated polymer dots for ultra-stable full-color fluorescence patterning.

    Science.gov (United States)

    Chang, Kaiwen; Liu, Zhihe; Chen, Haobin; Sheng, Lan; Zhang, Sean Xiao-An; Chiu, Daniel T; Yin, Shengyan; Wu, Changfeng; Qin, Weiping

    2014-11-12

    Stable full-color fluorescence patterning are achieved by multicolor polymer-dot inks. The fluorescent patterns show extraordinary stability upon various treatments, offering a superior combination of bright fluorescence, excellent photostability, chemical resistance, and eco-friendship. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Transvaginal color Doppler imaging of uterine contractions in early pregnancies: Significance of uterine contractions in early pregnancy failure

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Ju; Han, Chang Jin; Suh, Jung Ho; Kwon, Hyuck Chan [Aju University SChool of Medicine, Suwon (Korea, Republic of)

    1999-06-15

    To assess uterine contractions in early pregnancies using transvaginal color Doppler sonography (TVCDS) and to determine the role of uterine contractions in the diagnosis of early pregnancy failure. 76 patients with abnormal pregnancy diagnosed by sonography or histopathology up to 10 weeks of gestation and 38 normal pregnant women as the control group were examines with TVCDS. The presence of uterine contractions was determined by complete or partial disappearance of the color flow signals of vessels within myometrium, and the direction, amplitude (grade 1-3), and interval of uterine contractions were also evaluated. Uterine contractions were identified in 42 (55.3%) of 76 patients with abnormal pregnancy, whereas they were detected only in 2 (5.3%) of 38 normal pregnant women who had initial grade 1 contraction but disappeared in the follow-up study. In 26 patients with blighted ovum or missed abortion, 15 patients (57.7%),showed uterine contraction of grade 1 in 3 cases, grade 2 in 8 cases, and grade 3 in 4 cases and interval from 45 seconds to 5 minutes. In 30 patients with inevitable or incomplete abortion, 23 patients (76.6%) showed uterine contraction of grade 1 in 2 cases, grade 2 in 9 cases, and grade 3 in 12 cases and interval from 1 to 5 minutes. 4 (20%) of 20 patients with threatened abortion had uterine contraction of grade 2 and interval from 2 to 4 minutes. The presence of uterine contractions was significantly different in abnormal pregnancies compared with that of normal and also among the tree different groups of abnormal pregnancies, but the amplitude did not differ.

  19. Transvaginal color Doppler imaging of uterine contractions in early pregnancies: Significance of uterine contractions in early pregnancy failure

    International Nuclear Information System (INIS)

    Lee, Eun Ju; Han, Chang Jin; Suh, Jung Ho; Kwon, Hyuck Chan

    1999-01-01

    To assess uterine contractions in early pregnancies using transvaginal color Doppler sonography (TVCDS) and to determine the role of uterine contractions in the diagnosis of early pregnancy failure. 76 patients with abnormal pregnancy diagnosed by sonography or histopathology up to 10 weeks of gestation and 38 normal pregnant women as the control group were examines with TVCDS. The presence of uterine contractions was determined by complete or partial disappearance of the color flow signals of vessels within myometrium, and the direction, amplitude (grade 1-3), and interval of uterine contractions were also evaluated. Uterine contractions were identified in 42 (55.3%) of 76 patients with abnormal pregnancy, whereas they were detected only in 2 (5.3%) of 38 normal pregnant women who had initial grade 1 contraction but disappeared in the follow-up study. In 26 patients with blighted ovum or missed abortion, 15 patients (57.7%),showed uterine contraction of grade 1 in 3 cases, grade 2 in 8 cases, and grade 3 in 4 cases and interval from 45 seconds to 5 minutes. In 30 patients with inevitable or incomplete abortion, 23 patients (76.6%) showed uterine contraction of grade 1 in 2 cases, grade 2 in 9 cases, and grade 3 in 12 cases and interval from 1 to 5 minutes. 4 (20%) of 20 patients with threatened abortion had uterine contraction of grade 2 and interval from 2 to 4 minutes. The presence of uterine contractions was significantly different in abnormal pregnancies compared with that of normal and also among the tree different groups of abnormal pregnancies, but the amplitude did not differ.

  20. [Review on enterprises'eco-innovation].

    Science.gov (United States)

    Liao, Zhong Ju; Huang, Chao

    2017-12-01

    Eco-innovation is an important way to realize sustainable development. It has the dual positive externality of "knowledge spillover" and "environmental spillover", which has attracted much attention from theory and practice. In order to systematically grasp the current situation of eco-innovation, this study collected the relevant foreign literatures on eco-innovation in the past ten years, and made a systematic review of the definition, characteristics and dimensions of eco-innovation. Focusing on the theory of institutional theory, stakeholder theory and resource-based view, this paper explored the antecedents of eco-innovation. Then, this paper also demonstrated the positive and negative effects of eco-innovation on corporate financial performance, and the meditating and moderating mechanisms between eco-innovation and financial performance. Finally, based on the limitations of existing research, the future research direction was put forward.

  1. Avaliação do bem-estar fetal pela dopplervelocimetria com mapeamento em cores Evaluation of fetal well-being through color doppler velocimetry

    Directory of Open Access Journals (Sweden)

    Cleide Mara Mazzotti de Oliveira Franzin

    1999-01-01

    aorta, and the adverse perinatal results was established. The pregnant women selected for this study were submitted electively to cesarean sections, at the utmost four hours after the color Doppler examination. We considered as adverse perinatal results: Apgar score lower than seven at the 5th minute, neonatal intensive care unit hospitalization, intrauterine growth retardation, acute fetal distress, perinatal mortality, hypoglycemia, polycythemia, necrotizing enterocolitis, and cerebral hemorrhage. The indexes for the umbilical and middle cerebral arteries and the abdominal aorta were related, in each case, to the adverse perinatal results. Results: the systole/diastole umbilical artery ratio presented a higher sensitivity than the pulsatile and tolerance indexes. The Doppler study of the umbilical artery presented greater sensitivity than the middle cerebral artery and the abdominal aorta in detecting adverse perinatal results. Conclusion: the Doppler velocimetry of the umbilical and middle cerebral arteries presented good diagnostic capacity in evaluating fetal well-being, and a significant association with the adverse perinatal results.

  2. Manejo obstétrico de la deficiencia hereditaria de antitrombina durante el embarazo y puerperio. Dos casos clínicos

    Directory of Open Access Journals (Sweden)

    Milagros Cruz Martínez

    2015-12-01

    Full Text Available Resumen Introducción: la deficiencia de antitrombina III hereditaria es una rara enfermedad que afecta al 0.02-0.2% de la población. Puede presentar mayor frecuencia de complicaciones y resultados adversos tanto en la madre como en el feto. Se presenta el manejo obstétrico de dos gestaciones consecutivas en una mujer con deficiencia de antitrombina III. Descripción: en ambos embarazos la madre realiza profilaxis de la enfermedad tromboembólica con heparina de bajo peso molecular para evitar la aparición de esta patología tanto en el embarazo como en el puerperio y mejorar el flujo útero-placen-tario. Con respecto a las complicaciones obstétricas, sólo existe un enlentecimiento del crecimiento fetal que obliga a un control obstétrico estricto. En ambas gestaciones los estudios eco-Doppler están dentro de la normalidad lo que permite una conducta expectante, consiguiendo llegar a término. Discusión: la profilaxis con heparina de bajo peso molecular en las gestantes con esta trombofilia y las intervenciones preventivas de factores de riesgo de enfermedad tromboembólica, junto con un control obstétrico adecuado, ha conseguido evitar la apari-ción de complicaciones derivadas de esta patología en el embarazo y en el puerperio. Por otra parte, el control del crecimiento fetal y el estudio Eco-Doppler han permitido asegurar el bienestar fetal no adelan-tando el parto, consiguiendo partos a término.

  3. Contrast-enhanced power Doppler US in the characterization of renal masses

    International Nuclear Information System (INIS)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E.

    2000-01-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts [it

  4. Assessment of right ventricular systolic function by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjærgaard, Jesper

    2012-01-01

    This thesis summarizes a series of studies performed in order to assess the clinical usefulness of a novel echocardiographic technology that allows non-invasive assessment of regional right ventricular myocardial velocities and deformation: tissue Doppler echocardiography. While the technology...... is a promising tool for improving our understanding of right ventricular hemodynamics, several aspects of the technology must be evaluated. The accuracy and reproducibility of the technology is evaluated in vitro, and normal values, impact of changes in loading of the right ventricle, response to exercise...... on right ventricular hemodynamics: pulmonary embolism, Arrhythmogenic right ventricular cardiomyopathy and pulmonary regurgitation, the latter in an animal model. The conclusions of the thesis are: Color tissue Doppler echocardiography accurately measures velocities, SR and strain in vitro. No systematic...

  5. Application of Color Doppler Ultrasound in Renal Medullary Calcium%彩色多普勒超声在肾髓质钙质沉着症中的应用分析

    Institute of Scientific and Technical Information of China (English)

    金丽梅

    2016-01-01

    目的:分析彩色多普勒超声在肾髓质钙沉着症中的应用价值。方法回顾性分析2011—2015年期间在该院行彩色多普勒超声诊断肾髓质钙沉着症的68例患者的临床资料,观察患者的超声诊断特点以及血流动力学改变。结果68例行彩色多普勒超声诊断肾髓质钙沉着症的患者中,诊断阳性共65例,阴性3例,诊断的准确率为95.6%,65例肾髓质钙沉着症患者中包括皮质型30例,髓质型32例,混合型3例,患者的两侧肾脏大小正常,形态对称,包膜光滑,皮质和髓质界限较为清楚,肾脏的皮质厚度和回声均正常,在患者的髓质内,有密集点状的强回声,形态和椎体的形态基本一致,有一侧有弱声影。结论彩色多普勒超声在肾髓质钙沉着症中应用,准确率较高,可以有效的显示内部的形态、血流变化等指标,具有重要的临床诊断价值。%Objective To analyze the value of color Doppler ultrasound in the renal medulla of calcium applications. Methods Convenient selection a retrospective analysis of clinical data by color Doppler ultrasound diagnosis of renal medullary calcinosis disease 68 patients were retrospectively analyzed the period from 2011 to 2015, observed in patients with ultrasonic diagnostic characteristics and hemodynamic change. Results 68 patients with routine color Doppler ultra-sound diagnosis of renal medullary calcinosis disease, the diagnosis of a total of65 positive cases, negative in 3 cases, the diagnostic accuracy was 95.6%, 65 cases of renal medullary calcinosis patients included cortical 30 cases, 32 cases of medullary, mixed three cases, both sides of the patient's normal kidney size, shape symmetry, smooth coated, cortex and medulla boundaries more clearly, renal cortical thickness and echo were normal in patients within the medulla, a strong e-cho dense point-like, form and shape of the vertebral body are basically the same, there is one

  6. Establishment of an eco-compensation fund based on eco-services consumption.

    Science.gov (United States)

    Liu, Moucheng; Yang, Lun; Min, Qingwen

    2018-04-01

    Eco-compensation is a type of institutional arrangement that uses economic measures to adjust the relationships among stakeholders in order to conserve and/or sustainably use ecosystem services. The externality of the value of ecosystem services is one of the theoretical bases for eco-compensation. Different types of ecosystem services are consumed by people from different regions. Some are consumed by people living where the services originate, while some are carried by rivers, wind, vehicles or other natural or manmade means to other areas. Thus, the flow and consumption of ecosystem services should be seen as the basis for establishing eco-compensation funds. This paper uses satellite images of the Zhang-Cheng area near Beijing in 2013 to discuss how to establish an eco-compensation fund for stakeholders in this area. Firstly, six important types of ecosystem services in the Zhang-Cheng area were identified based on ecological function zoning, and the value of these ecosystem services was calculated based on ecological pricing methods. Secondly, the field intensity model from physics was used to analyze where Zhang-Cheng area ecosystem services flowed and calculate how much of these services were used by other areas. Thirdly, based on this analysis and calculation, the paper proposes the rates that different stakeholders should invest in the eco-compensation fund, based on their consumption of eco-services. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. [Parenchymal complications of the transplanted kidney: the role of color-Doppler imaging].

    Science.gov (United States)

    Granata, Antonio; Clementi, Silvia; Clementi, Anna; Di Pietro, Fabio; Scarfia, Viviana R; Insalaco, Monica; Aucella, Filippo; Prencipe, Michele; Fiorini, Fulvio; Sicurezza, Elvia

    2012-01-01

    Kidney transplantation is the treatment of choice for end-stage renal disease, given the better quality of life of transplanted patients when compared to patients on maintenance dialysis. In spite of surgical improvements and new immunosuppressive regimens, part of the transplanted grafts still develop chronic dysfunction. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of vascular and surgical complications of the transplanted kidney, its role is not fully understood in case of parenchymal complications of the graft. The specificity of Doppler ultrasound is low both in case of acute complications such as acute tubular necrosis, drug toxicity and acute rejection, and in case of chronic conditions such as chronic allograft nephropathy. Single determinations of resistance indices present low diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including tissue pulsatility index, maximal fractional area and contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of parenchymal complications of the transplanted kidney.

  8. SELECTIVE AND NONSELECTIVE β-BLOCKERS IN PRIMARY OPEN ANGLE GLAUCOMA THERAPY – RESULTS OF COLOR DOPPLER SONOGRAPHY

    Directory of Open Access Journals (Sweden)

    Vukoslava Maričić-Došen

    2002-12-01

    Full Text Available Background. Primary open angle glaucoma (POAG is a syndrome of progressive optic neuropathy characterized by optic nerve head excavation and visual field defects. Poor correlation between IOP and progression of glaucoma disease sets vascular mechanism in the centre of attention. By Color Doppler sonography, quantification of blood flow changes in vessels, which supply optic nerve head, is possible. We wanted to find out whether there are changes in the circulation of central retinal artery and posterior ciliary arteries in patients with primary open angle glaucoma treated with selective or nonselective β -blockers.Methods. 44 patients (88 eyes were divided into two groups: group 1: 22 patients (44 eyes treated with selective β -blockers (Betaxolol 0.5% and group 2: 22 patients (44 eyes treated with nonselective β -blockers (Timolol 0.5%. Vascular indices (RI, PI were measured in the central retinal artery and posterior ciliary arteries.Results. We found decreased blood flow and increased vascular indices in both groups of patients, statistically significant difference between group 1 and group 2: blood flow velocity was higher and vascular indices were lower in group 1 (Betaxolol 0.5% compared to group 2 (Timolol 0..5%.Conclusions. Selective β -blockers (calcium channel blockers act more vasoactively and neuroprotectively comparing to nonselective β -blockers.

  9. Quantitation of stress echocardiography by tissue Doppler and strain rate imaging: a dream come true?

    Science.gov (United States)

    Galderisi, Maurizio; Mele, Donato; Marino, Paolo Nicola

    2005-01-01

    Tissue Doppler (TD) is an ultrasound tool providing a quantitative agreement of left ventricular regional myocardial function in different modalities. Spectral pulsed wave (PW) TD, performed online during the examination, measures instantaneous myocardial velocities. By means of color TD, velocity images are digitally stored for subsequent off-line analysis and mean myocardial velocities are measured. An implementation of color TD includes strain rate imaging (SRI), based on post-processing conversion of regional velocities in local myocardial deformation rate (strain rate) and percent deformation (strain). These three modalities have been applied to stress echocardiography for quantitative evaluation of regional left ventricular function and detection of ischemia and viability. They present advantages and limitations. PWTD does not permit the simultaneous assessment of multiple walls and therefore is not compatible with clinical stress echocardiography while it could be used in a laboratory setting. Color TD provides a spatial map of velocity throughout the myocardium but its results are strongly affected by the frame rate. Both color TD and PWTD are also influenced by overall cardiac motion and tethering from adjacent segments and require reference velocity values for interpretation of regional left ventricular function. High frame rate (i.e. > 150 ms) post-processing-derived SRI can potentially overcome these limitations, since measurements of myocardial deformation have not any significant apex-to-base gradient. Preliminary studies have shown encouraging results about the ability of SRI to detect ischemia and viability, in terms of both strain rate changes and/or evidence of post-systolic thickening. SRI is, however, Doppler-dependent and time-consuming. Further technical refinements are needed to improve its application and introduce new ultrasound modalities to overcome the limitations of the Doppler-derived deformation analysis.

  10. Deep vein thrombosis of the lower limbs: A retrospective analysis of doppler ultrasound findings

    Directory of Open Access Journals (Sweden)

    Sanjay M Khaladkar

    2014-01-01

    Full Text Available Background: Deep venous thrombosis (DVT of lower limbs is one of the most common cause for the majority of deaths caused by pulmonary embolism. Many medical and surgical disorders are complicated by DVT. Most venous thrombi are clinically silent. B-mode and color Doppler imaging is needed for early diagnosis of DVT to prevent complications and sequalae of DVT. Aim and Objectives: The objectives of the following study were to evaluate the role of Doppler as an imaging modality in diagnosing DVT of lower limbs, to study the spectrum of findings on Doppler ultrasound in patients with DVT. Materials and Methods: Retrospective descriptive analysis of 78 patients of DVT diagnosed on Doppler. Results: Nearly 74% of the patients were males and 26% were females with majority belonging to fifth decade (26%. 75 (96.1% cases showed unilateral while 3 (3.9% cases showed bilateral lower limb involvement. In our study, predominant distribution of thrombus was found to be in above knee region with 69/78 (88.5% patients having thrombus in the superficial femoral vein. Popliteal vein was involved in 54/78 (69.2% patients. Complete thrombosis was observed in 54/78 (69% cases, while partial thrombosis was observed in 24/78 (31% cases. Subacute stage was seen in 42 cases (53.8%, acute stage in 23 cases (29.5% while chronic stage in 13 cases (16.7%. 71 cases (91% had multiple contiguous segmental involvement, whereas 7 cases (9% had isolated vein involvement. Conclusion: Color Doppler is useful in diagnosing DVT in symptomatic and at risk patients and provides a non-invasive method of investigation. It is also helpful in evaluating the site, extent and stage of thrombus.

  11. Tissue Doppler echocardiography – A case of right tool, wrong use

    Directory of Open Access Journals (Sweden)

    Thomas George

    2004-08-01

    Full Text Available Abstract Background The developments in echocardiography or ultrasound cardiography (UCG have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE is one such example? Presentation of the hypothesis TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. Testing the hypothesis To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. Implications of the hypothesis As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.

  12. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

    Directory of Open Access Journals (Sweden)

    Anderson Chun On Tsang

    2015-04-01

    Full Text Available Purpose: The aim of this study was to validate a computational fluid dynamics (CFD simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents.

  13. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  14. The clinical study of 2D and power doppler ultrasound in esophagus varix

    International Nuclear Information System (INIS)

    Li Qiang; Zhou Liang; Zhang Yucheng; Yang Minghua; Ruan Fenglian; Lu Haixia; Li Yue

    2008-01-01

    Objective: To study the application of 2D and Power Doppler Ultrasound in diagnosing the abdominal esophageal varicose veins. Methods: 65 patients under suspicion with chronic hepatitis and cirrhosis for esophageal varicose at esophagus in abdomen section were examined by 2D and Power Doppler Ultrasound.Among them, 35 patients suffered from esophageal varicose veins proved by gastroscopy and the rest did not. Results: On the power doppler imaging map, colored blood stream signals were showed in varicose veins while without signals in non-varicose veins.The diagnostic sensitivity and specificity were 91.4% and 100% respectively. On the two-dimensional image chart, non-echoes were represented in varicose veins. The anteroposterior diameter, right-left diameter, as well as the thickness of esophagus wall were larger in patients with varicose veins than those in non varicose veins cases (P<0.01). Conclusion: 2D combined with Power Doppler Ultrasound was of non-invasive, safe, sensitive and high specificity, which is a valuable and practical tool in diagnosing the esophageal varicose veins. (authors)

  15. Two-dimensional color Doppler echocardiography for left ventricular stroke volume assessment: a comparison study with three-dimensional echocardiography.

    Science.gov (United States)

    Silva, Cristina Da; Pedro, Fátima; Deister, Lizandra; Sahlén, Anders; Manouras, Aristomenis; Shahgaldi, Kambiz

    2012-08-01

    Whether measurement of left ventricular outflow tract diameter (LVOTd) using color Doppler (CD) in order to more accurately define LVOTd is more accurate for determination of stroke volume (SV) than gray scale and compare it with direct measurement of LVOT area (a) using three-dimensional echocardiography (3DE) for SV determination. Twenty-one volunteers were examined. LVOTa was calculated by two-dimensional echocardiography (2DE) using the following formula: π× (d/2)(2) , d = LVOT diameter by gray scale and CD, respectively. Planimetry of LVOTa was performed in parasternal long axis using 3DE. Eccentricity Index was calculated using the lateral and anterior-posterior LVOTd. SV was obtained by four different methods: (1) 2D gray scale, (2) 2D color, (3) LVOTa × LVOT velocity time integral, and (4) SV by Simpson's biplane method. Gray scale LVOTd was significantly smaller compared to LVOTd obtained with CD (P vs 3.67 ± 0.70 cm(2) , P vs 3.61 ± 0.89 cm(2) , P = 0.011). Half of the subjects had at least 17% difference between the lateral and anterior-posterior LVOTd. There were significant differences between SV by 2D gray scale and 2D CD (82.8 ± 17.1 mL vs 92.4 ± 16.8 mL, P vs 90.7 ± 19.8 mL, P = 0.025). Our study demonstrates LVOT being frequently elliptical. SV and LVOTa were found to be similar when comparing 2DE CD and 3DE planimetry and showed higher values in comparison to 2DE gray scale, which suggests 2DE CD to be an alternative approach for SV assessment. © 2012, Wiley Periodicals, Inc.

  16. The Study of Critical Eco-Linguistic in Green Discourse: Prospective Eco-Linguistic Analysis

    Directory of Open Access Journals (Sweden)

    Tommi Yuniawan

    2017-10-01

    Full Text Available Eco-linguistic studies are influenced by one of the other interdisciplinary sciences, namely critical discourse analysis. The combination of these two sciences is called critical eco-linguistic studies. Critical eco-linguistic examines the discourse about the environment and various forms of discourse and their ideology which concerns people and the environment. The environmental discourse with all its manifestations (oral text, written text is called green discourse. To that end, critical eco-linguistic dictates the linguistic aspects contained in the green discourse. Utilization of lingual units in green discourse will affect the sense and logic of people involved in the discourse, ie the writers and readers or the speakers and the speakers. What is recorded in their cognition, will affect their attitudes and actions to the environment. If green discourse is constructive, then their attitude and actions to the environment are constructive. Conversely, if green discourse is more destructive and exploitative, then their attitudes and actions towards the environment will also be affected towards destruction and exploitation. For this reason, critical eco-linguistic studies in green discourse deserve to be given space as a form of prospective eco-linguistic analysis.

  17. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  18. An eco-friendly dyeing of woolen yarn by Terminalia chebula extract with evaluations of kinetic and adsorption characteristics.

    Science.gov (United States)

    Shabbir, Mohd; Rather, Luqman Jameel; Shahid-Ul-Islam; Bukhari, Mohd Nadeem; Shahid, Mohd; Ali Khan, Mohd; Mohammad, Faqeer

    2016-05-01

    In the present study Terminalia chebula was used as an eco-friendly natural colorant for sustainable textile coloration of woolen yarn with primary emphasis on thermodynamic and kinetic adsorption aspects of dyeing processes. Polyphenols and ellagitannins are the main coloring components of the dye extract. Assessment of the effect of pH on dye adsorption showed an increase in adsorption capacity with decreasing pH. Effect of temperature on dye adsorption showed 80 °C as optimum temperature for wool dyeing with T. chebula dye extract. Two kinetic equations, namely pseudo first-order and pseudo second-order equations, were employed to investigate the adsorption rates. Pseudo second-order model provided the best fit (R (2) = 0.9908) to the experimental data. The equilibrium adsorption data were fitted by Freundlich and Langmuir isotherm models. The adsorption behavior accorded well (R (2) = 0.9937) with Langmuir isotherm model. Variety of eco-friendly and sustainable shades were developed in combination with small amount of metallic mordants and assessed in terms of colorimetric (CIEL(∗) a (∗) b (∗) and K/S) properties measured using spectrophotometer under D65 illuminant (10° standard observer). The fastness properties of dyed woolen yarn against light, washing, dry and wet rubbing were also evaluated.

  19. An eco-friendly dyeing of woolen yarn by Terminalia chebula extract with evaluations of kinetic and adsorption characteristics

    Science.gov (United States)

    Shabbir, Mohd; Rather, Luqman Jameel; Shahid-ul-Islam; Bukhari, Mohd Nadeem; Shahid, Mohd; Ali Khan, Mohd; Mohammad, Faqeer

    2016-01-01

    In the present study Terminalia chebula was used as an eco-friendly natural colorant for sustainable textile coloration of woolen yarn with primary emphasis on thermodynamic and kinetic adsorption aspects of dyeing processes. Polyphenols and ellagitannins are the main coloring components of the dye extract. Assessment of the effect of pH on dye adsorption showed an increase in adsorption capacity with decreasing pH. Effect of temperature on dye adsorption showed 80 °C as optimum temperature for wool dyeing with T. chebula dye extract. Two kinetic equations, namely pseudo first-order and pseudo second-order equations, were employed to investigate the adsorption rates. Pseudo second-order model provided the best fit (R2 = 0.9908) to the experimental data. The equilibrium adsorption data were fitted by Freundlich and Langmuir isotherm models. The adsorption behavior accorded well (R2 = 0.9937) with Langmuir isotherm model. Variety of eco-friendly and sustainable shades were developed in combination with small amount of metallic mordants and assessed in terms of colorimetric (CIEL∗a∗b∗ and K/S) properties measured using spectrophotometer under D65 illuminant (10° standard observer). The fastness properties of dyed woolen yarn against light, washing, dry and wet rubbing were also evaluated. PMID:27222752

  20. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  1. High-resolution color Doppler ultrasonographic characteritics of lymphatic malformations%淋巴管畸形的高频超声与彩色多普勒特点

    Institute of Scientific and Technical Information of China (English)

    张梅; 谷凌云; 李宪坤; 许雅琴; 郝岩

    2012-01-01

    目的 研究淋巴管畸形的高频超声及彩色多普勒超声表现特点并进行分析、总结.方法 应用高频超声及彩色多普勒超声对23例淋巴管畸形的二维灰阶超声声像图及彩色血流信号进行回顾性研究.超声扫查内容包括:病变大小、边界、内部回声、彩色血流信号及用脉冲多普勒测量血流速度.结果 17例淋巴管畸形(74%,17/23)位于颈部、颌下或腋下,6例位于其他部位;21例位于皮下组织内,其中3例同时累及真皮及肌层.13例大囊型淋巴管畸型,均显示为较大的无回声区,有分隔,壁光滑,其中2例大囊型合并感染,无回声区内有稀疏低回声;5例混合型淋巴管畸形,为淋巴管畸形和血管畸形混合存在,超声显示为大小不等的无回声区有分隔,合并局部微小无回声区或不规则的小的实性低回声区,其中3例侵及肌层;5例微囊型淋巴管畸形,超声显示以无回声区为主,内有少量的低回声区,形成囊实混合性病变.所有病例无回声区内彩色多普勒扫查均无彩色血流信号.8例大囊型及3例混合型淋巴管畸形周边扫查到彩色血流信号,2例微囊型内部实性低回声内显示有彩色血流信号.脉冲多普勒检查最大血流速度18~73 cm/s,阻力指数0.55~0.72.结论 淋巴管畸形的高频超声及彩色超声多普勒成像有显著的特点,以较大的无回声区为主,多发可有分隔,无回声区内无血流信号,大部分位于皮下组织内,基于以上特点,可确诊大部分病例,因而高频超声及彩色多普勒是诊断淋巴管畸形的较好方法.%Objective To analyse the characteristics and diagnostic value of high resolution grayscale and color Doppler ultrasound in lymphatic malformations . Methods Twenty-three lymphatic malformations were evaluated by 7-12 MHz high-resolution grayscale and color Doppler ultrasound . All the cases were comfirmed by histopathologic diagnosis . The size, location, margin, echo

  2. The Role of Interaction Patterns with Hybrid Electric Vehicle Eco-Features for Drivers' Eco-Driving Performance.

    Science.gov (United States)

    Arend, Matthias G; Franke, Thomas

    2017-03-01

    The objective of the present research was to understand drivers' interaction patterns with hybrid electric vehicles' (HEV) eco-features (electric propulsion, regenerative braking, neutral mode) and their relationship to fuel efficiency and driver characteristics (technical system knowledge, eco-driving motivation). Eco-driving (driving behaviors performed to achieve higher fuel efficiency) has the potential to reduce CO 2 emissions caused by road vehicles. Eco-driving in HEVs is particularly challenging due to the systems' dynamic energy flows. As a result, drivers are likely to show diverse eco-driving behaviors, depending on factors like knowledge and motivation. The eco-features represent an interface for the control of the systems' energy flows. A sample of 121 HEV drivers who had constantly logged their fuel consumption prior to the study participated in an online questionnaire. Drivers' interaction patterns with the eco-features were related to fuel efficiency. A common factor was identified in an exploratory factor analysis, characterizing the intensity of actively dealing with electric energy, which was also related to fuel efficiency. Driver characteristics were not related to this factor, yet they were significant predictors of fuel efficiency. From the perspective of user-energy interaction, the relationship of the aggregated factor to fuel efficiency emphasizes the central role of drivers' perception of and interaction with energy conversions in determining HEV eco-driving success. To arrive at an in-depth understanding of drivers' eco-driving behaviors that can guide interface design, authors of future research should be concerned with the psychological processes that underlie drivers' interaction patterns with eco-features.

  3. Eco-feedback for non-consumption

    NARCIS (Netherlands)

    Lim, V.; Jense, A.; Janmaat, J.; Funk, M.

    2014-01-01

    Eco-feedback is a strategy to increase awareness of resource use and to encourage conservation. We applied eco-feedback on household food waste with the prospective to increase awareness and explore its impact on food related decision-making. In this paper we present a prototype of an eco-feedback

  4. Eco-friendly Development Of Industry

    International Nuclear Information System (INIS)

    An, Gi Cheol; Park, Hun; Lee, Dong Jin; Ryu, Sang Hui

    1998-02-01

    This book reports eco-friendly development of industry, which has summary on bring up the issue and research way and system of research. It deals with current state of affairs on eco-friendly development of industry and the case of developed countries such as necessity and meaning of eco-friendly development industry, prospect and change of the tendency, environmental issue by field in Korea like the steel industry, nonferrous metal industry, auto industry, and cement industry and general policy for eco-friendly development of industry.

  5. Spontaneous development of bilateral subdural hematomas in an infant with benign infantile hydrocephalus: color Doppler assessment of vessels traversing extra-axial spaces

    Energy Technology Data Exchange (ETDEWEB)

    Amodio, John; Spektor, Vadim; Pramanik, Bidyut; Rivera, Rafael; Pinkney, Lynne; Fefferman, Nancy [New York University Medical Center, Department of Radiology, New York, NY (United States)

    2005-11-01

    We present an infant with macrocrania, who initially demonstrated prominent extra-axial fluid collections on sonography of the brain, compatible with benign infantile hydrocephalus (BIH). Because of increasing macrocrania, a follow-up sonogram of the brain was performed; it revealed progressive enlargement of the extra-axial spaces, which now had echogenic debris. Color Doppler US showed bridging veins traversing these extra-axial spaces, so it was initially thought that these spaces were subarachnoid in nature (positive cortical vein sign). However, an arachnoid membrane was identified superior to the cortex, and there was compression of true cortical vessels beneath this dural membrane. An MRI of the brain showed the extra-axial spaces to represent bilateral subdural hematomas. The pathogenesis of spontaneous development of the subdural hematomas, in the setting of BIH, is discussed. We also emphasize that visualizing traversing bridging veins through extra-axial spaces does not necessarily imply that these spaces are subarachnoid in origin. (orig.)

  6. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  7. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  8. Envasado de Carne de Vacuno con Hueso y Grasa en Atmósfera Modificada con CO2 y CO

    OpenAIRE

    Aspé, Estrella R; Roeckel, Marlene D; Martí, Cristina; Jiménez, Romel

    2008-01-01

    Se evaluó el efecto de envasado en atmósfera modificada (MAP) con bajo contenido de CO (0.1% y 0.4%) y presencia de CO2 sobre el color rojo y la vida útil de carne de vacuno. Se determinaron características microbiológicas, fisicoquímicas, organolépticas-sensoriales y de color del músculo y se compararon los resultados con el MAP de 70%O2+30%CO2. La vida útil de las muestras con O2 fue de 30 días mientras que para las muestras en MAP la vida útil fue de 40 a 45 días y no dependió de la concen...

  9. Prognostic Value of Cardiac Time Intervals by Tissue Doppler Imaging M-Mode in Patients With Acute ST-Segment-Elevation Myocardial Infarction Treated With Primary Percutaneous Coronary Intervention

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; Søgaard, Peter

    2013-01-01

    Background- Color tissue Doppler imaging M-mode through the mitral leaflet is an easy and precise method to estimate all cardiac time intervals from 1 cardiac cycle and thereby obtain the myocardial performance index (MPI). However, the prognostic value of the cardiac time intervals and the MPI...... assessed by color tissue Doppler imaging M-mode through the mitral leaflet in patients with ST-segment-elevation myocardial infarction (MI) is unknown. Methods and Results- In total, 391 patients were admitted with an ST-segment-elevation MI, treated with primary percutaneous coronary intervention...

  10. Influence of double cropping on growth and yield of dry beans with colored plastic mulches Influencia del doble cultivo en el crecimiento y rendimiento de frijol con cubierta plástica de colores

    Directory of Open Access Journals (Sweden)

    Luis Ibarra-Jiménez

    2012-12-01

    suelo desnudo. El diseno experimental fue bloques completos al azar con cuatro repeticiones. El porcentaje de radiación fotosintéticamente activa (PAR reflejada por las cubiertas tendió a ser mayor en el plástico blanco-sobre-negro y menor en cubierta negra. La temperatura media bajo la cubierta decreció con el incremento en el porcentaje de PAR reflejada. La temperatura media del suelo se relacionó con rendimiento en 98% y 99% en la primera y segunda estación de crecimiento, respectivamente. La relación entre PAR y rendimiento fue 98% y 86% en la primera y segunda estación de crecimiento, respectivamente. El efecto de la cubierta de color sobre el rendimiento fue significativo (p < 0,05 en la primera estación de crecimiento, pero no en el segundo cultivo donde los tratamientos de cubierta y el control tuvieron un rendimiento similar, indicando que no siempre la cubierta aumenta el rendimiento.

  11. DETERMINACIÓN DEL COLOR EN EPICARPIO DE TOMATES (LYCOPERSICUM ESCULENTUM MILL. CON SISTEMA DE VISIÓN COMPUTARIZADA DURANTE LA MADURACIÓN

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Padrón Pereira

    2012-01-01

    Full Text Available Se estudió la evolución del color de muestras de tomates durante la maduración a temperatura ambiente y otras en refrigeración, mediante Sistema de Visión Computarizada (SVC. El SVC lo constituye un escenario iluminado, una cámara digital CCD y un computador (Laptop ambos calibrados. El procesamiento digital de las imágenes se llevó a cabo con el software Adobe® Photoshop® CS3 Extended, con los cuales generaron imágenes promediadas en coordenadas L*, a* y b*. La relación a*/b* y las coordenadas polares c* y hº, que presentaron diferencias estadísticas significativas entre las muestras determinadas (p<0,05.

  12. The transabdominal chorionic villus sampling puncture guided by color Doppler ultrasound during early pregnancy

    International Nuclear Information System (INIS)

    Liang Weixiang; Chen Zhiyi; Yuan Wenlin; Cai Kuan; Zhu Junlin; Wang Weiqun; Chen Xia

    2008-01-01

    Objective: To study the operation of chorionic villus sampling (CVS) guided by color Doppler ultrasound (CDU) via abdomen puncture during early pregnancy and investigate the advertences during the operation. Methods: CVS guided by CDU probe via abdomen puncture were operated on 28 pregnant women who had the indications of antenatal diagnosis. CDU was used to observe the implantation position of the fo1iaceous villis and help setting mark of the puncture point and puncture range on body surface before operation. The needle was punctured under real-time ultrasound guidance and villis were aspirated during the operation: The choice of the right time of puncture and the operation skills were emphasized in the study. Results: The CVS puncture approach should be set through CDU ob servation, which attend to avoid the surrounding blood vessels, intestinal canal and surrounding important organs. The puncture point should be chosen in a point where lobif0rmed villis distributed wider and with a larger scope. The operations were performed from 10 to13 weeks of pregnancy, with an average of 11 weeks. Among these 28 cases, 9.6 were successfully drawn materials in one time, 1 in twice and l failure, with the total ratio of achievement was 96.4%. For all the cases, fetal heart pulsating could be seen by real-time CDU observation fight after the operation, and no larger hematoma echo in the placental site occurred. Ultrasound reexamined one week after the operation, fetal heart pulsation could be found in all cases, and no abortion cases occurred after regular follow-up in 25 continued pregnant patients. Conclusion: Abdominal CVS puncture guided by CDU probe is conveniently operated, safe and available in clinic. It is an important method for antenatal diagnosis during early pregnancy. The puncture localization, skills and the time are the key points for the success in obtaining the materials. (authors)

  13. Color Doppler evaluation of the ocular arterial flow changes in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Ozer, Tulay; Altin, Remzi; Ugurbas, Suat Hayri; Ozer, Yetkin; Mahmutyazicioglu, Kamran; Kart, Levent

    2006-01-01

    Purpose: To evaluate the hemodynamic changes in the extraocular orbital vessels of the patients with chronic obstructive pulmonary disease (COPD), using color Doppler ultrasonography (CDU) technique, and to compare the results with those of healthy control subjects. Methods: Forty-five patients with COPD and 17 healthy control subjects were included in this study. Patients with COPD were classified according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD). Fifteen patients of stage I COPD (mild airflow limitation), stage II COPD (worsening airflow limitation) or stage III COPD (severe airflow limitation) were enrolled into Group I, II and III, respectively. End tidal carbon dioxide (EtCO 2 ), peripheral oxygen saturation (SpO 2 ), pulse rate (PR) and respiratory rate (RR) were measured by using capnograph/pulse oximeter in all patients. Measurements were performed in only one randomly chosen eye of each participant. The peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistance index (RI) were measured in the ophthalmic artery (OA), central retinal artery (CRA), lateral short posterior ciliary artery (LPCA) and medial short posterior ciliary artery (MPCA), using CDU technique. Results: The PSV measurements of the OA were significantly higher in Groups II and III compared to control group (p 2 with PSV (r = 0.53, p < 0.01) and EDV (r = 0.51, p < 0.01) of the OA. Statistically significant correlations were also found for the SpO2 with RI (r = -0.34, p < 0.05) in the OA. Conclusion: We concluded that COPD is associated with impaired retrobulbar hemodynamics, especially in the ophthalmic artery. Moreover, central retinal and posterior ciliary arteries with increased resistance are also found to be affected when compared with healthy control eyes

  14. Decision making in the treatment of peripheral arterial disease - A single-institution comparative study using information from color doppler and digital subtraction angiogram studies

    International Nuclear Information System (INIS)

    Koshy, Chiramel G; Chacko, Binita R; Keshava, Shyamkumar N; Stephen, Edwin; Agarwal, Sunil

    2011-01-01

    Numerous studies have compared the accuracy of color Doppler (CD) with that of digital subtraction angiography (DSA) in the diagnosis of peripheral arterial disease (PAD). However, only a few have looked at the influence of these diagnostic tests on the treatment decision in PAD. This study evaluated the differences in treatment decisions that were based on CD and with those based on DSA findings. Findings from CD and DSA studies obtained in 40 patients were entered on line diagrams by two radiologists working separately. These were randomized and sent to three experienced clinicians – two vascular surgeons and one interventional radiologist. The treatment decisions of the clinicians based on each proforma were collected and analyzed to look for the degree of agreement between Doppler-based and DSA-based decisions. There was fair to moderate agreement between CD-based and DSA-based decisions for all three clinicians, with some improvement in agreement with the addition of clinical data. The vascular surgeons showed better agreement with each other on treatment decisions compared to the interventional radiologist who showed a fair-to-moderate level of agreement with the vascular surgeons, which did not significantly change with the addition of clinical data. There is a fair to moderate agreement between treatment decisions based on CD findings and those based on DSA findings. We conclude that CD along with clinical data is sufficient to make decisions in the treatment of PAD

  15. Transvaginal color Doppler ultrasound in the diagnosis of endometrial lesions%经阴道彩色多普勒超声在子宫内膜病变诊断的应用价值

    Institute of Scientific and Technical Information of China (English)

    高鸣

    2015-01-01

    目的 探讨经阴道彩色多普勒超声在子宫内膜病变诊断中的应用价值,总结其应用经验.方法 对90例不规则阴道流血患者行经阴道彩色多普勒超声检查,分析其超声影像学资料,并将超声检查结果与诊刮以及患者术后病理诊断结果相对照.结果 本研究90例患者经阴道彩色多普勒超声检查确诊86例,其中子宫内膜增生36例、子宫内膜息肉42例,子宫内膜癌8例,确诊率为95.64%;漏诊4例,漏诊率为4.36%,其中1例子宫内膜癌病变,3例子宫内膜增生病变.结论 经阴道彩色多普勒超声检查子宫内膜病变操作简便、准确性高,超声检查时应注意测量子宫内膜厚度,观察内膜形态、内膜与肌层的关系、内膜回声特点以及子宫内膜内血流情况及阻力指数,作为诊断子宫内膜病变的重要检查方法,还需要结合患者的临床表现及其他影像学检查手段,以提高其确诊率.%Objective To investigate the application value of transvaginal color Doppler ultrasound in the diagnosis of endometrial lesions,and summarize the application experience.Methods Ninety patients with irregular vaginal bleeding underwent transvaginal color Doppler ultrasound examination,the ultrasound image data were analyzed,and the ultrasonic inspection results and curettage and postoperative pathological diagnosis results were compared.Results Among the 90 cases,86 cases were diagnosed by transvaginal color Doppler ultrasound,of which 36 cases of endometrial hyperplasia,42 cases of endometrial polyps,endometrial carcinoma in 8 cases,the diagnosis rate was 95.64% ; 4 cases of missed diagnosis,the missed diagnosis rate was 4.36%,in which l case of endometrial carcinoma lesions,3 cases of uterus hyperplasia lesions.Conclusions Transvaginal color Doppler ultrasonography for endometrial lesions has simple operation,high accuracy,we should pay attention to measure the thickness of endometrium,endometrial morphology

  16. Analisa Swot Pada Kawasan Industri Candi Jawa Tengah Menuju Eco Industrial Park

    OpenAIRE

    Hervino, Prayudha Budi; Puspitasari, Nia Budi

    2014-01-01

    Industrial park in Indonesia must pay attention to continuous development and environmentally conscious, which is in line with constitution number 3 of 2014. The development of Candi Industrial Park has been inducing the presence of pros and cons from surrounding society. According to the chief of Purwoyoso, liquid waste and noise from production process of Candi Industrial Park could still be found. The primary concept of Eco Industrial Park (EIP) is to build an industry that is environmenta...

  17. The role of Doppler measurement in the adducting uterine veins in diagnosis of endometrial tumors

    International Nuclear Information System (INIS)

    Abdullaev, R.Ya.; Pozdnyakov, S.A.

    2010-01-01

    The work deals with investigation of the capabilities of transvaginal ultrasound investigation in combination with color, energetic and spectral Doppler investigation in differential diagnosis of benign endometrial hyperplasia and cancer. The work is based on complex investigation of 66 pre- and post- menopause patients with histologically verified pathology of the endometrium.

  18. ECO-DRIVING MODELING ENVIRONMENT

    Science.gov (United States)

    2015-11-01

    This research project aims to examine the eco-driving modeling capabilities of different traffic modeling tools available and to develop a driver-simulator-based eco-driving modeling tool to evaluate driver behavior and to reliably estimate or measur...

  19. From “eco-pessimism” to “eco-optimism” ECOMOG And The West ...

    African Journals Online (AJOL)

    From “eco-pessimism” to “eco-optimism” ECOMOG And The West African Integration Process. Emmanuel Kwesi Aning. Abstract. No Abstract African Journal of Political Science Vol.4(1) 1999: 21-39. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT.

  20. Does Nationality Matter in Eco-Behaviour?

    Directory of Open Access Journals (Sweden)

    Michelle Bonera

    2017-09-01

    Full Text Available Although many authors agree on the role of personal values in explaining the main determinants of eco-behaviour, disagreement about the effects of socio-demographic features exists, particularly about the effect of nationality. In an attempt to fill this gap in the literature, this paper contributes to the debate surrounding the main determinants of eco-behaviour, based on a cross-country analysis. To test the role of nationality and personal values in eco-behaviour, a linear regression model involving 353 Chinese and 333 Italian subjects was performed. A stepwise analysis was then conducted to identify the main significant effects. The explorative and stepwise analyses confirmed that nationality is significant when explaining individual eco-behaviour, for both Italian and Chinese people. Moreover, the linear regression model, as a stepwise analysis, showed that regulatory focus and universalism are the main personal values influencing ecological behaviour. Differences emerging from the analysis show significant differences in terms of eco-behaviour and eco-awareness, for the two countries involved in the analysis, that might lead companies to adopt different marketing strategies when promoting eco-products.

  1. Morfología ecocardiográfica de la atresia pulmonar con septum interventricular intacto, estudio de dos decenios

    Directory of Open Access Journals (Sweden)

    Adel Eladio González Morejón

    2013-03-01

    Full Text Available Introducción: la atresia pulmonar con septum interventricular intacto es una malformación cardiovascular que representa el 1 % de las cardiopatías congénitas observadas en vida extrauterina, y, dados sus resultados desfavorables, constituye un verdadero reto para la medicina contemporánea. Objetivo: la investigación condujo a la aplicación de pautas clasificatorias, a la caracterización del tracto de salida atrésico, al estudio morfológico ventricular derecho, a la valoración del anillo tricuspídeo y a la determinación de la presencia de anomalías en la circulación coronaria. Métodos: se estudiaron 43 pacientes con diagnóstico confirmado de la entidad remitidos al Cardiocentro Pediátrico "William Soler" entre enero de 1992 y noviembre de 2011. Se practicó a cada caso el examen ecocardiográfico bidimensional y doppler con codificación en colores. Resultados y conclusiones: se corroboró el predominio de la variante morfológica valvular de la entidad y la existencia de niveles moderados o severos de hipoplasia ventricular derecha en asociación con capacitancia volumétrica limitada de dicha cámara, con hipodesarrollo valvular tricuspídeo y con presencia de circulación coronaria anómala sinusoides dependiente. El foramen oval permeable constituyó el defecto septal interatrial más vinculado a la enfermedad, y se evidenciaron diversas anomalías estructurales del aparato tricuspídeo en conjunción o no con el hipodesarrollo anular imperante.

  2. Facile and eco-friendly fabrication of AgNPs coated silk for antibacterial and antioxidant textiles using honeysuckle extract.

    Science.gov (United States)

    Zhou, Yuyang; Tang, Ren-Cheng

    2018-01-01

    Recently, there is a growing trend towards the functionalization of silk through nanotechnology for the prevention of fiber damage from microbial attack and the enhancement of hygienic aspects. Considering sustainable development and environmental protection, the eco-friendly fabrication of silver nanoparticles (AgNPs)-modified silk using natural extracts has currently become a hot research area. This study presents a facile strategy for the fabrication of colorful and multifunctional silk fabric using biogenic AgNPs prepared by honeysuckle extract as natural reductant and stabilizing agents. The influences of pH and reactant concentrations on the AgNPs synthesis were investigated. The color characteristics and functionalities of AgNPs treated silk were evaluated. The results revealed that the particle size of AgNPs decreased with increasing pH. The diameter of AgNPs decreased with increasing amount of honeysuckle extract and reducing amount of silver nitrate. The transmission electron microscopy image showed that the AgNPs were spherical in shape with a narrow size distribution. The treated silk showed excellent antibacterial activities against E. coli and S. aureus, and certain antioxidant activity. Both of the antibacterial and antioxidant activities were well maintained even after 30 washing cycles. This work provides a sustainable and eco-friendly approach to the fabrication of AgNPs coated silk for colorful and long-term multifunctional textiles using honeysuckle extract. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  4. Resolution and Micro-Doppler Effect in Bi-ISAR System (in English

    Directory of Open Access Journals (Sweden)

    Deng Dong-hu

    2013-06-01

    Full Text Available Compared to the monostatic radar, bistatic radar has many special characteristics because of its spatial complexity. Bistatic Inverse Synthetic Aperture Radar (Bi-ISAR can be employed as a radar imaging tool for obtaining non-cooperative target images. In this study, we first analyze the range and azimuth resolution of a Bi-ISAR system. To analyze this azimuth resolution and its spatial-variety characteristic, a definition called con-Doppler bandwidth is introduced, which helps overcome the difficulty of the target’s viewing angle diversity calculation. Then, a detailed investigation is conducted to study the micro-Doppler effect caused by the vibration and the rotation of the target in the Bi-ISAR system. By comparing the difference in the micro-Doppler effect between the Bi-ISAR system and the Mono-ISAR system, we modify the extended Hough transform to extract the real micro-motion features of the targets. Finally, we provide some simulation results to validate the theoretical derivation and to illustrate the effectiveness of the proposed method.

  5. Biorremediacion de suelos contaminados con hidrocarburos

    OpenAIRE

    Ortiz, E.; Núñez, R.; Fonseca, E.; Oramas, J.; Almazán, V.; Cabranes, Y.; Miranda, A.; Barbán, O.; Martínez, C.; Díaz, Y.; Borges, G.

    2005-01-01

    En la actualidad los suelos contaminados con hidrocarburos representan el 70% del total de los eco-sistemas impactados. A partir del aislamiento, selección y conservación de bacterias marinas degra-dadoras de hidrocarburos y productoras de sustancias tensioactivas se formuló un producto denomi-nado BIOIL-FC. Este producto ha sido aplicado satisfactoriamente en derrames de hidrocarburos en el mar. En el presente trabajo fue evaluada la factibilidad del uso de los procesos de biorremediación “e...

  6. Eco-Innovation in Circular Agri-Business

    Directory of Open Access Journals (Sweden)

    Dong-Her Shih

    2018-04-01

    Full Text Available This study constructs a theory of eco-innovation in circular agri-business. Although previous studies have discussed eco-innovation in circular agri-business, they did not address eco-innovation from the perspective of a closed-loop sustainable supply chain. Hence, this study applied the fuzzy TOPSIS method to conduct the analysis and determine the interrelationship between eco-innovation and the closed-loop concept. The results are consistent with the theory and a significant improvement in terms of the decisive attributes. The findings suggest that improving water management, relationships with suppliers, knowledge sharing, environmental management systems, and new product and service development are the most effective and efficient ways to build eco-innovation in circular agri-business. The managerial and theoretical implications are discussed.

  7. La eco ruta cultural Mojanda-Cochasquí: una propuesta de desarrollo turístico sostenible para la zona rural de la provincia de Pichincha, Ecuador

    Directory of Open Access Journals (Sweden)

    M.Sc. María Cristina Villacís Mejía

    2016-12-01

    Full Text Available El Ministerio de Turismo del Ecuador ha identificado un número considerable de destinos a los que se debe dotar de facilidades turísticas, planes de ordenamiento territorial, señalización turística, servicios y capacitación de sus recursos humanos, sobre todo con la finalidad de beneficiar a las poblaciones locales por medio del desarrollo turístico de estas zonas. La Dirección de Rutas de este Ministerio determinó las rutas turísticas que contribuyen a identificar el territorio, esto sobre la base de un conjunto de criterios establecidos. Entre dichos destinos se encuentra la Eco Ruta Cultural Mojanda-Cochasquí. En esta investigación se establece el concepto de ecorruta cultural en un escenario de proliferación de nuevas ofertas turísticas a nivel local y nacional. La propuesta apunta a dinamizar la economía de la zona que abarca la Eco Ruta Mojanda-Cochasquí mediante la articulación del potencial económicoproductivo, con los recursos turísticos identificados en ella, de manera que se favorezca la participación de los actores locales en esta construcción. Para ello, el estudio propone revisar la documentación relacionada con la Eco Ruta objeto de análisis, así como un estudio empírico que incluye la realización de un trabajo de campo con carácter participativo en toda el área.

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... asociados con los lentes de contacto de color Sep. 26, 2013 It started as an impulsive buy ... to its original shape after wearing orthokeratology lenses? Sep 13, 2017 Histoplasmosis Diagnosis Sep 01, 2017 How ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Peligros asociados con los lentes de contacto de color Sep. 26, 2013 It started as an impulsive ... after your vision… The Mystery of the Ghostly White Ring MAR 30, 2018 By Dan T. Gudgel ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Eye Health ... Leer en Español: Peligros asociados con los lentes de contacto de color Sep. 26, ...

  11. Low-frequency high-definition power Doppler in visualizing and defining fetal pulmonary venous connections.

    Science.gov (United States)

    Liu, Lin; He, Yihua; Li, Zhian; Gu, Xiaoyan; Zhang, Ye; Zhang, Lianzhong

    2014-07-01

    The use of low-frequency high-definition power Doppler in assessing and defining pulmonary venous connections was investigated. Study A included 260 fetuses at gestational ages ranging from 18 to 36 weeks. Pulmonary veins were assessed by performing two-dimensional B-mode imaging, color Doppler flow imaging (CDFI), and low-frequency high-definition power Doppler. A score of 1 was assigned if one pulmonary vein was visualized, 2 if two pulmonary veins were visualized, 3 if three pulmonary veins were visualized, and 4 if four pulmonary veins were visualized. The detection rate between Exam-1 and Exam-2 (intra-observer variability) and between Exam-1 and Exam-3 (inter-observer variability) was compared. In study B, five cases with abnormal pulmonary venous connection were diagnosed and compared to their anatomical examination. In study A, there was a significant difference between CDFI and low-frequency high-definition power Doppler for the four pulmonary veins observed (P low-frequency high-definition power Doppler was higher than that when employing two-dimensional B-mode imaging or CDFI. There was no significant difference between the intra- and inter-observer variabilities using low-frequency high-definition power Doppler display of pulmonary veins (P > 0.05). The coefficient correlation between Exam-1 and Exam-2 was 0.844, and the coefficient correlation between Exam-1 and Exam-3 was 0.821. In study B, one case of total anomalous pulmonary venous return and four cases of partial anomalous pulmonary venous return were diagnosed by low-frequency high-definition power Doppler and confirmed by autopsy. The assessment of pulmonary venous connections by low-frequency high-definition power Doppler is advantageous. Pulmonary venous anatomy can and should be monitored during fetal heart examination.

  12. Usefulness of the myocardial performance index determined by tissue Doppler imaging m-mode for predicting mortality in the general population

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Haahr-Pedersen, Sune Ammentorp

    2011-01-01

    The objective of this study was to evaluate the prognostic value of the myocardial performance index (MPI), assessed by color-coded tissue Doppler imaging (TDI) M-mode through the anterior mitral leaflet. Color TDI M-mode through the mitral leaflet is an easy, very fast, and precise method...... ventricular in- and outflow using standard procedures (MPI(conv)) and by color-coded TDI M-mode through the mitral leaflet in the apical 4-chamber view (MPI(TDI)). MPI(TDI) was increased in subjects with coronary heart disease (CHD) compared to controls, even after multivariable adjustment (p

  13. Umberto Eco - autobiograf?

    Directory of Open Access Journals (Sweden)

    Regina Lubas-Bartoszyńska

    2009-01-01

    Full Text Available This text shows that U. Eco is an autobiographer in only some sense of the word. He has not written an autobiobiographical text in which he would present a segment of his life. However, he told the history of his novelistic work and presented his intellectual train of thought in his essays, interviews, introductions to his works. There also exists an indirect autobiographism in Eco, which expresses signs of the author's life and of his personality dispersed in his interpretative and theoretical writings on literature, aesthetics, history, in his feuilletons and in his novels. Five types of autobiographism have been distinguished in Eco as well as five autobiographical strategies within the indirect autobiographism. The first strategy - a strong presence of autorial I in the text - is not sufficient and requires support of some other of the strategies discussed.

  14. Application of Energy Window Concept in Doppler Broadening of {sup 238}U Cross Section

    Energy Technology Data Exchange (ETDEWEB)

    Khassnov, Azamat; Choi, Soo Young; Lee, Deok Jung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2014-10-15

    Currently, the NJOY code is used for construction and Doppler broadening of microscopic cross sections. There exist several methods or formalisms to produce microscopic cross sections and there are also different methods of Doppler broadening. In this paper, Multi-Level Breit-Wigner (MLBW) formalism and the Psi method are used for generation and Doppler broadening of the resonance cross section. Accuracy of the energy window concept applied MLBW (EW MLBW) Doppler broadened cross section was compared with that of the cross section generated by conventional MLBW (Con MLBW) formalism for {sup 2}38U isotope using MATLAB. The conventional method requires Doppler broadening of all resonances, including resonances far from the target energy point, which do not change much with respect to the temperature change. The energy window concept makes Doppler broadening possible with a smaller number of resonances neighboring to the energy point we are interested in, and just adds up 0 K temperature cross sections of other resonances. Multi-level Breit-Wigner formalism and the Doppler broadening method were used to construct microscopic cross sections of {sup 238}U at different temperatures. The energy window concept was applied only for the 1st resonance energy region (4.5∼11.2 eV). The energy window concept demonstrates high competitiveness because the relative differences were less than 0.0016% for all types of cross sections. The advantage of the energy window concept is that the number of resonances broadened for every energy point is significantly reduced, which allows a reduction of computation time by almost 45 % of Doppler broadening time of the cross section generation at temperatures higher than 0 K.

  15. Policy Instruments for Eco-Innovation in Asian Countries

    OpenAIRE

    Jang, Eun; Park, Mi; Roh, Tae; Han, Ki

    2015-01-01

    Eco-innovation globally emerged as an effort to implement sustainable development. States and firms established and implemented policies and strategies for eco-innovation as one route to achieving sustainable development. Eco-innovation has been facilitated in developed countries, specifically OECD members and European countries, through action plans. Recently, eco-innovation policies have emerged in developing countries. Thus, this study analyzes eco-innovation policies in Asian countries. ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Without a Prescription Leer en Español: Peligros asociados con los lentes de contacto de color Sep. 26, ... not just at Halloween. But few know the risks associated with these lenses . "Most people believe that ...

  17. Normal reference values for vertebral artery flow volume by color Doppler sonography in Korean adults

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2003-09-15

    Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 +- 39.7 ml/min for the right side and 127.6 +- 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 +- 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 +- 59.19 ml/min in male, and 217.28 +- 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.

  18. Normal reference values for vertebral artery flow volume by color Doppler sonography in Korean adults

    International Nuclear Information System (INIS)

    Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol

    2003-01-01

    Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 ± 39.7 ml/min for the right side and 127.6 ± 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 ± 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 ± 59.19 ml/min in male, and 217.28 ± 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.

  19. ECO-INNOVATION FOR A SUSTAINABLE FUTURE

    Directory of Open Access Journals (Sweden)

    RATIU Mariana

    2014-05-01

    Full Text Available Eco-innovation is any form of innovation resulting in or aiming at significant and demonstrable progress towards the goal of sustainable development, through reducing impacts on the environment, enhancing resilience to environmental pressures, or achieving a more efficient and responsible use of natural resources. States and governments of the world, different institutions and organizations actively involved and aware in public policies, strategies and actions, reaffirm their commitments and reassess actions in order to achieve a truly sustainable development. In the common vision and the resolutions and other documents of the United Nations Conference on Sustainable Development, Rio+20, the words "environment", "innovation", "green economy" appear very often and almost always along the same context, to achieve the objectives of the sustainable development. The objectives of EU's Europe 2020 strategy for smart, sustainable and inclusive growth, are being implemented through a number of Flagship Initiatives addressing the main challenges, like “Innovation for a sustainable Future - The Eco-innovation Action Plan (EcoAP”. Eco-innovation Observatory developed the Eco-Innovation index, the first tool to assess and illustrate eco-innovation performance across the EU Member States. Like in all fields, in textiles and leather field, eco-innovation is present and there are a lot of tools available that measure environmental damage and help manufacturers and brands become more sustainable. Eco-innovation is not just a trendy concept but a reality and a necessity nowadays, a way to achieve a sustainable future for ourselves and future generations.

  20. Clinical utility of eco-color-power Doppler ultrasonography and contrast enhanced magnetic resonance imaging for interpretation and quantification of joint synovitis: a review.

    Science.gov (United States)

    Carotti, Marina; Galeazzi, Vittoria; Catucci, Francesca; Zappia, Marcello; Arrigoni, Francesco; Barile, Antonio; Giovagnoni, Andrea

    2018-01-19

    With the introduction of new biologics such as anti-TNF-alpha antibodies and other therapies in the treatment of inflammatory arthritis, capable of halting joint destruction and functional disability, there are new pressures on diagnostic and prognostic imaging. Early demonstration of pre-erosive inflammatory features and monitoring of the long-term effects of treatment are becoming increasingly important. Early detection of synovitis offers advantages in terms of allowing early instigation of therapy and may allow the identification of those patients displaying more aggressive disease who might benefit from early intervention with expensive DMARD therapy. Advanced imaging techniques such as ultrasound (US) and magnetic resonance imaging (MRI) have focussed on the demonstration and quantification of synovitis and allow early diagnosis of inflammatory arthropathies such as rheumatoid arthritis (RA) and psoriatic arthritis (PsA). Synovitis represents a potential surrogate measure of disease activity that can be monitored using either MRI or US; the techniques have, generally, focused on monitoring synovial volume or quality as assessed by its vascularity. However to achieve these goals, standardisation and validation of US and MRI are required to ensure accurate diagnosis, reproducibility and reliability. Each modality has different strengths and weaknesses and levels of validation. This article aims to increase the awareness of radiologists and rheumatologists about this field and to encourage them to participate and contribute to the ongoing development of these modalities. Without this collaboration, it is unlikely that these modalities will reach their full potential in the field of rheumatological imaging. This review is in two parts. The first part addresses the role of US and colour or power Doppler sonography (PDUS) in the detection and monitoring of synovitis in inflammatory arthropathies. The second part will look at advanced MR imaging and Dynamic contrast

  1. Perspective on Eco-Hydrology Developing Strategy in China

    Science.gov (United States)

    Xia, J.

    2017-12-01

    China is one of developing countries with higher eco-environmental press in the world due to large population and its socio-economic development. In China, water is not only the sources for life, but also the key for production, and the foundation for eco-system. Thus, Eco-hydrology becomes a fundamental also an applied sciences related to describe the hydrologic mechanisms that underlie ecologic patterns and processes. This paper addresses the issue of Eco-hydrology Developing Strategy in China, supported by Chinese Academy of Sciences (CAS). Major contents include four aspects, namely: (1) Demands and frontier of eco-hydrology in the world; (2) Major theories and approaches of Eco-hydrology; (3) Perspective of future development on Eco-hydrology; (4) Enacting and proposal for China development strategy on Eco-hydrology. Application fields involves urban, rural area, wetland, river & lake, forest and special regions in China, such as the arid and semi-arid region and so on. The goal is to promote the disciplinary development of eco-hydrology, and serve for national demands on ecological civilization construction in China.

  2. Feedback-Based Eco-Design for Integrating the Recency, Frequency, and Monetary Value of Eco-Efficiency into Sustainability Management

    Directory of Open Access Journals (Sweden)

    Rui Yang Chen

    2016-09-01

    Full Text Available Customer feedback is used to understand customer requirements. Early design phases require the consideration of items including manufacturing, the environment, and sustainability management. Therefore, it is crucial that eco-efficiency is taken into account in the early design phases. Traditionally, eco-efficiency is considered only in terms of eco-design issues, not customer requirements based on business values such as Recency, Frequency, and Monetary (RFM value. In the meantime, integrating innovation from eco-design is one important aspect. Here, I propose that customer feedback-based eco-efficiency and TRIZ-based innovation can be considered in early eco-design based on the RFM value for sustainability management. The analytic hierarchy process (AHP and fuzzy-based AHP were integrated to explore the relative weights of RFM variables for business value evaluation. The innovative method of the paper is using a TRIZ contradiction matrix associated with engineering parameters for eco-design. The experimental study has been carried out, and it meets the forecasting business value for green product usage. The business value was used as the decision-making factor in order to evaluate both environmental and marketing performance.

  3. DEMONSTRATION BULLETIN: THE ECO LOGIC THERMAL DESORPTION UNIT - MIDDLEGROUND LANDFILL - BAY CITY, MI - ELI ECO LOGIC INTERNATIONAL, INC.

    Science.gov (United States)

    ECO Logic has developed a thermal desorption unit 0"DU) for the treatment of soils contaminated with hazardous organic contaminants. This TDU has been designed to be used in conjunction with Eco Logic's patented gas-phase chemical reduction reactor. The Eco Logic reactor is the s...

  4. Sonographic evaluation of thyroiditis with color flow study.

    Science.gov (United States)

    Sultana, N; Rima, S; Rahman, S; Azad, S A; Karim, M E; Shawkat, S; Ahsan, M; Kamal, M M; Begum, M

    2014-01-01

    This cross sectional study was carried out in the Department of Radiology and Imaging, Bangabandhu Sheikh Mujib Medical University, Bangladesh in collaboration with the Department of Endocrinology and Department of Histopathology of the same hospital during the period of March 2007 to February 2008 to determine efficacy of ultrasonogram in the evaluation of thyroiditis and to compare its results with color flow Doppler study. For this purpose, a total of 50 patients having clinical suspicion of thyroiditis were enrolled in this study. Ultrasound and color Doppler were done in all these patients. Then all patients underwent for FNAC in the Histopathology department. Correlation between sonographic diagnosis and histopathological diagnosis were observed. Out of these 50 patients 10(20%) were male and 40 (80%) were female with age ranging from 12 to 50 years, highest between 21 to 30 years. The mean age of the patients was 30.42±9.57 years. On unltrasonographic findings of thyroid gland 42.0% patients had regular and 58.0% had irregular margin. Seventy percent had fibrosis, 14.0% had feature of necrosis, 48.0% had lymphadenopathy. Out of all patients 6.0% had normal echogenic feature, 16.0% had increased and 78.0% decreased echogeneic feature. Twelve percent (12.0%) patients had homogeneous and 88.0% had heterogeneous pattern of echogenecity. Thirty eight percent (38%) patients had focal nodules. Sixty percent (60.0%) patients had focal swelling and 40.0% had diffuse swelling. On color flow Doppler 28.0% had normal, 38.0% had increased and 34.0% decreased vascular flow pattern. USG reports revealed that 48.0% had thyromegaly, 36.0% had thyroid nodule, 10.0% had multinodular goiter and 6.0% had thyroid abscess. FNAC diagnosis revealed that 34.0% patients had Hashimoto's thyroiditis, 24.0% had lymphocytic thyroiditis, 18.0% had granulomatous thyroiditis, 6.0% had abscess, 8.0% had goitre and 10.0% nonspecific. USG and CFD are recommended modalities for the diagnosis of

  5. Doppler echography and utilization of intravenous echo enhancer in the follow-up of hepato carcinoma with percutaneous radiological techniques; Ecografia Doppler y empleo del ecopotenciador intravenoso en el seguimiento del hepatocarcinoma con tecnicas radiologicas percutaneas

    Energy Technology Data Exchange (ETDEWEB)

    Forner, J; Flored de la Torre, M.; Senis, C; Lozano de Arnilla, M C; Ferrer, S; Celma, M I [Hospital General Universitario de Valencia. Valencia (Spain)

    2002-07-01

    To evaluate the utilization of Doppler ultrasound scan in conjunction with echographic enhancer in the follow-up of hepato carcinomas treated by means of radiological intervention techniques. We treated 20 hepatic nodules diagnosed with hepato carcinoma either by means of chemo embolization or percutaneously (either injection of acetic acid or radio-frequency thermo-ablation). Doppler ultrasound scan was performed before and after the treatment by means of sectorial and convex multifrequency probes. Evaluated were the absence, presence and degree of vascularisation, as well as its distribution and characteristics. In all cases, a contrast-en-handed spiral CT was performed. Both studies served as a pattern for comparison before and after treatment. In post-treatment enhanced-echo-Doppler controls of the 18 patients treated with acetic acid, vascularisation was not demonstrated in 7 cases, peripheral vascularisation was detected in 4 cases, perforation vascularisation in another four, and central vascularisation was detected in 3 cases. Contrast-enhanced spiral CT demonstrated superimposed findings, except in one cases, in which the spiral CT detected central capitation of the nodule.With enhanced echo-Doppler, peripheral vascularisation was detected. In both nodules treated by means of radio-frequency thermo ablation, there was detected neither vascularisation in the echo-Doppler nor captation of contrast media in the CT. Doppler ultrasound scan is a good method of follow-up for treated hepato carcinomas. The utilization of echoenhancers increases its ability to detect vascularization it being comparable to that of contrast-enhanced CT. As such, Doppler ultrasound scan together with echoenhancers can help us both in the selection of treatment and evaluation of therapeutic response. (Author) 35 refs.

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Leer en Español: Peligros asociados con los lentes de contacto de color Sep. 26, 2013 It started as an ... the cause: a rare inflammatory condition called Cogan’s syndrome. Google AI May Reveal Health Risks Through Your ...

  7. Eco-innovations in the functioning of companies.

    Science.gov (United States)

    Ociepa-Kubicka, A; Pachura, P

    2017-07-01

    The development of entrepreneurships in the 21st century cannot occur without taking care of the natural environment. The article presents issues related to eco-innovation. Despite the opportunities offered by eco-innovations, implementation of such initiatives remains to lead to various difficulties. They vary across countries and sectors. The insufficient number of enterprises in Poland and other European countries implement adequate level of eco-innovations. The main aim of this paper is to indicate the causes of this status and activities aimed to develop eco-innovativeness. The benefits and risks connected with implementation of innovative products and technologies were also discussed. Furthermore, the advantages of and barriers to their implementation into companies were analysed. The entrepreneurs from the least eco-innovative countries emphasize serious barriers, including uncertain demand from the market, uncertain return on investment or too long a payback period for eco-innovation, lack of funds within the enterprise, insufficient access to existing subsidies and fiscal incentive. They are especially afraid of the financial risks, which raises uncertainty and leads to refraining from innovative initiatives. The possibilities were indicated for the entrepreneurs who face problems with the implementation of innovative solutions. Particular attention was paid to the European Union activities for the development of eco-innovations. Numerous programs supporting their implementation were indicated. The article also presents examples of eco-innovation in water and sewage enterprises. It was emphasized that planning of eco-innovative solutions should be based on comprehensive information about actual benefits and possibility of threats to the environment which can be caused by implementation of eco-innovations. The study presents the example of threats resulting from different methods of sewage sludge management. Copyright © 2017 Elsevier Inc. All rights

  8. On eco-planning for an eco-demonstration park (EDP) and sustainability-Case study of the Luhua EDP in the Chongming Island of Shanghai,China

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The background,concept,connotation,principles,and methods ofeco-planning for an Eco-Demonstration Park (EDP) and sustainability were examined based on a case study of the Luhua EDP in the Chongming Island of Shanghai,China,which is an important part of Shanghai Eco-city planning and construction in the 21st century.By analyzing natural,social and economic conditions,calculating population using the land capacity eco-model,eco-function zoning,and eco-construction,an innovative eco-industrial structure and technical chain were formulated.A comprehensive eco-planning scheme for the EDP was proposed,including planning and management strategies for subsystems of efficient industry,good quality human settlement,high standard eco-construction and eco-tourism as well as effective environmental protection and attractive landscape.The EDP should be an area with coordinated and sustainable economic,social and environmental subsystems.Eco-planning for the EDP should be a very important part of eco-city planning and sustainability.The paper aims to set up a theoretical framework and practical basis for eco-planning and promoting harmony between human and nature.

  9. Georeferenciación de datos obtenidos a través de Radio Eco-Sondaje al norte de la Península Antártica

    OpenAIRE

    Cárdenas,Carlos; Carvallo,Rubén; Dodman,Cristian; Johnson,Erling; Hernández,Jorge

    2011-01-01

    Esta investigación presenta los datos del trabajo realizado con Sistemas de Posicionamiento Global (GPS) como complemento al trabajo de Radio Eco-Sondaje realizado en enero de 2009 en las proximidades a la Estación Base Chilena Bernardo O’Higgins y la montaña Jakenau al norte de la península antártica (63° 19’ S, 57° 51’ W). El objetivo principal fue georreferenciar la información correspondiente a la zona de grietas identificada mediante Radio Eco-Sondaje, utilizando dos eq...

  10. Eco-efficiency in industrial production

    NARCIS (Netherlands)

    von Raesfeld Meijer, Ariane M.; de Bakker, F.G.A.; Groen, Arend J.

    2001-01-01

    English AbstractThis report of the MATRIC project investigated 'Eco-efficiency in industrial production'. After a general introduction into the domain of eco-efficiency, the first part of this report further focusses on the organisation of Product-Oriented Environmental Management (POEM), which is

  11. Eco-Schools campaign. The European projects

    International Nuclear Information System (INIS)

    Blanchini, P.; Marino, G.

    1999-01-01

    The Foundation for Environmental Education in Europe (FEEE) was established in 1981; since then it was been actively promoting and delivering education through a series of successful internationals programmes launched in 21 different European nations. The Eco-School Campaign aims to raise students' awareness of environment issues through classroom study, and provide an integrated system for environmental management of schools based on EMAS (with waste, water and energy management as priority areas). As a process of facilitating sustainable developpement at a local level, pupils are encouraged to take an active role in mental impact of the schools. The Eco-Schools Green Flag, awarded to schools with high achievement in their Programme, is a recognised and respected eco-label for environmental education and performance. In Italy the National Eco-Schools operator was asked to set up a ten-schools pilot programme in the region Friuli Venezia Giulia: these are very first national schools that are likely to become 'Eco-Schools'

  12. The economic value of corporate eco-efficiency

    NARCIS (Netherlands)

    Guenster, N.; Bauer, R.; Derwall, J.M.M.; Koedijk, C.G.

    2011-01-01

    This study adds new insights to the long-running corporate environmental-financial performance debate by focusing on the concept of eco-efficiency. Using a new database of eco-efficiency scores, we analyse the relation between eco-efficiency and financial performance from 1997 to 2004. We report

  13. Delitos sexuales: Anteproyecto de reforma del Código Penal de 2008. Defensa en procesos con víctimas menores. Castración química

    OpenAIRE

    Prieto Rodríguez, Javier Ignacio

    2009-01-01

    Los delitos sexuales devienen singularmente llamativos, con importante eco social, cuando los perjudicados son niños o menores de edad. Aborda el presente estudio la incidencia que en la sociedad española, con la consiguiente reacción de los poderes

  14. An R&D Management Framework for Eco-Technology

    Directory of Open Access Journals (Sweden)

    Kenji Sano

    2011-08-01

    Full Text Available Although research and development (R&D affects new value-added creation, including that related to environmental aspects, there is little literature dealing with the integration of R&D management and eco-value. Here, eco-value of technology is defined as the advantage of environmental competitiveness in the market. This paper proposes a framework of R&D management of eco-technology (RDMOET, consisting of: (1 future research for sustainability; (2 making an original eco-theme portfolio and roadmap; (3 gap analysis and implementation of new eco-themes; and (4 eco-value evaluation. (1 and (4 are new processes compared with conventional R&D management. Through practice at the Corporate R&D Center of Toshiba Corporation, the usefulness of the proposed framework is verified from the viewpoint of not only technological eco-innovation, but also that of organizational learning for environmental sustainability.

  15. Eco-efficiency and control loop configuration for recycle systems

    Energy Technology Data Exchange (ETDEWEB)

    Munir, Muhammad Tajammal; Yu, Wei; Young, Brent P. [The University of Auckland, Auckland (New Zealand)

    2013-05-15

    To integrate measurements of eco-efficiency with control loop configuration has become an important topic since all industrial processes/plants are requested to increase their eco-efficiency. The exergy eco-efficiency factor, a new measure of eco-efficiency for control loop configuration, has been developed recently. The exergy eco-efficiency factor is based on the thermodynamic concept of exergy, which can be used to analyze a process in terms of its efficiency. The combination of the relative gain array (RGA), NI, CN, dynamic RGA, and the exergy eco-efficiency factor will help guide the process designer to find the optimal control design with low operating cost/eco-efficiency. In this paper, we validate the proposed exergy eco-efficiency factor for processes with recycles which are very common industrially.

  16. Eco-efficiency and control loop configuration for recycle systems

    International Nuclear Information System (INIS)

    Munir, Muhammad Tajammal; Yu, Wei; Young, Brent P.

    2013-01-01

    To integrate measurements of eco-efficiency with control loop configuration has become an important topic since all industrial processes/plants are requested to increase their eco-efficiency. The exergy eco-efficiency factor, a new measure of eco-efficiency for control loop configuration, has been developed recently. The exergy eco-efficiency factor is based on the thermodynamic concept of exergy, which can be used to analyze a process in terms of its efficiency. The combination of the relative gain array (RGA), NI, CN, dynamic RGA, and the exergy eco-efficiency factor will help guide the process designer to find the optimal control design with low operating cost/eco-efficiency. In this paper, we validate the proposed exergy eco-efficiency factor for processes with recycles which are very common industrially

  17. Diagnosic evaluation study of color doppler ultrasonic examination in abdominal wall endometriosis%彩色多普勒高频超声对腹壁子宫内膜异位症的诊断价值研究

    Institute of Scientific and Technical Information of China (English)

    史淼; 亓恒涛; 王倩; 张东东; 章阳

    2014-01-01

    Objective To explore the color doppler ultrasound manifestation of abdominal wall endometriosis,and evaluate its clinical value. Methods The manifestation of two-dimensional high frequency ultrasonography and color doppler imaging of 36 patients withabdominal wall endometriosis,which proven by surgery and pathology,were retrospectively analyzed.Results Among the 36 patients with abdominal wall endometriosis,1 6 cases located in fat layer,20 cases in muscular layer,with diameter ranging from 1 .1 to 5 .2 cm.With two-dimensionalultrasonography,there was no capsule,but with irregular morphology,blurred margins,low echoes inside and some parts of irregular no-echo areas.The size and internal echo of the mass changed respectively according to the menstruation.Color doppler ultrasound showed scattered or striped flow signals in the lesion,whose artery displayed low-speed and high resistance frequency spectrum.The accuracy and misdiagnosis rate of ultrasonography were 83.3% and 1 6.7%, respectively.Conclusions The color doppler ultrasound may directlydisplay the size,morphology,condition of internal echo and blood inflow of the abdominal wall endometriosis lesion.Therefore,it is the first choice of imaging examination for the diagnosis of abdominal wall endometriosis.%目的:探讨腹壁子宫内膜异位症的彩色多普勒高频超声表现,评价其临床应用价值。方法回顾性分析2010年2月至2013年12月,山东省聊城市人民医院经手术病理证实的腹壁子宫内膜异位症患者36例的高频超声二维图像及彩色多普勒超声表现。结果36例腹壁子宫内膜异位症患者中,位于脂肪层内16例,位于肌层内20例,直径1.1~5.2 cm。二维超声表现:无包膜,形态不规则,边缘不光滑,内部为不均质低回声,随月经的不同时期肿块大小及回声呈相应改变。彩色多普勒超声显示病灶内部可见点状或条状血流信号,其动脉均为

  18. Endovascular treatment of splenic artery aneurysms; Trattamento endovascolare degli aneurismi dell'arteria splenica

    Energy Technology Data Exchange (ETDEWEB)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Dizonno, Massimiliano; Fugazzola, Carlo [Insubria Univ., Varese (Italy). Cattedra di radiologia; Castelli, Patrizio [Insubria Univ., Varese (Italy). Chirurgia vascolare

    2005-07-15

    techniques, endovascular treatment is feasible in nearly all SAAs. It ensures good immediate and long term results, and no doubt presents some advantages in comparison to surgical treatment, as it less invasive and allows the preservation of splenic function. [Italian] Scopo. Verificare l'efficacia del trattamento endovascolare degli aneurismi dell'arteria splenica (AAS). Materiale e metodi. Nel periodo compreso tra maggio 2000 e giugno 2003 sono stati trattati 11 AAS veri in 9 pazienti (7 femmine e 2 maschi; eta media 58 anni), 8 sacciformi e 3 fusiformi, 4 localizzati al tratto medio, 5 al tratto distale e 2 intrasplenici. La diagnosi e stata effettuata con eco color Doppler e/o angio-TC ed e risultata occasionate in 7 pazienti e conseguente a dolore in ipocondrio sinistro in 1 caso; un AAS e stato riscontrato in fase di fissurazione. Quattro AAS sono stati esclusi mediante embolizzazione della sacca con microspirali, con preservazione della continuita dell'asse vascolare; in 2 casi e stata associata l'iniezione transcatetere di cianoacrilato. In 4 casi e stata effettuata una legatura endovascolare, con ischemia settoriaie della milza. Un AAS fisstirato e stato trattato in urgenza con embolizzazione massiva mediante cianoacrilato dell'arteria splenica. I 2 aneurismi intrasplenici sono stati esclusi, l'uno mediante embolizzazione dell'arteria afferente con cianoacrilato e l'altro con iniezione transcatetere di trombina nella sacca aneurismatica. Risultati. E stata ottenuta la devascolarizzazione completa di tutti gli AAS (in 10/11 al termine della procedura; in 1/11 al controllo TC, effettuato dopo 3 giorni). Il follow-up (durata media 18 mesi; range 6-36 mesi) e stato espletato con eco color Doppler e/o angio-TC a 3, 6, 12 mesi e successivamente una volta all'anno; la completa esclusione degli aneurismi e stata confermata in 11/11 casi. Le complicanze riscontrate sono state: 4 casi di pleurite sinistra di modesta entita; febbre

  19. Virgin olive oil color and perceived quality among consumers in emerging olive-growing countries

    Directory of Open Access Journals (Sweden)

    Gámbaro, A.

    2014-06-01

    Full Text Available Five virgin olive oil samples were evaluated by 122 consumers for their color acceptability and expected quality on 9-point structured scales. A description of the attributes expected in the different oils was obtained from the responding consumers by means of a check-all-that-apply questionnaire consisting of a list of 17 possible virgin olive oil attributes. Hierarchical cluster analysis led to the identification of two consumer clusters with distinct behavior. Whereas one consumer cluster attributed higher quality to those oils that were greener in color, which they described as tasty, rich-flavored, strong-tasting, herb-flavored and expensive, consumers in the other cluster assumed that greener olive oils were of a poorer quality, as they described them as strange-tasting, strong-tasting, herb-tasting and defective. Despite the contrasting perception of a virgin olive oil’s green color, the respondents, irrespective of cluster, presumed that the virgin olive oil that was the yellowest in color was of poor quality and cheap, also assuming that it had a milder taste than the other oils.122 consumidores evaluaron el color de 5 muestras de aceite de oliva virgen, midiendo su aceptabilidad y la calidad esperada por medio de una escala estructurada de 9 puntos y describiéndolas por medio de preguntas “marque todo lo que corresponde” que consiste en una lista de 17 términos posibles para atributos de aceites de oliva extra vírgenes. Mediante un análisis de conglomerados jerárquico se identificó a dos grupos de consumidores Los consumidores de ambos grupos consideraron que los aceites más amarillos eran de baja calidad, describiéndolos como baratos y de gusto suave. Un grupo de consumidores asignó puntuaciones de calidad alta a todos los aceites con colores verdes, describiéndolos como sabrosos, aromáticos, con gusto fuerte, con sabor a hierba y caros. El otro grupo de consumidores consideró que los aceites de color verde m

  20. Practical Eco-Design and Eco-Innovation of Consumer Electronics—the Case of Mobile Phones

    Directory of Open Access Journals (Sweden)

    Anders S. G. Andrae

    2016-02-01

    Full Text Available Annually, it is estimated that about 4 billion units of consumer electronics for mobile communications are produced worldwide. This could lead to various ecological imbalances unless the design and disposal of the products are handled optimally. To illustrate how industry looks at and responds to the increasing social awareness, this article describes how sustainability is successfully implemented in practice at a large Chinese company, developing and producing various kinds of electronic products used for communication. It also describes how a variety of eco-innovations and business models contribute to reducing the environmental impact; for example, through increased recovery and recycling. A new kind of eco-design procedure is presented along with a new methodology which shows how a mobile phone gradually becomes more sustainable from one generation to the next. The issues with and set-up of new eco-labeling schemes for mobile phones, eco-rating, is described in detail. The conclusion is that due to high competition between companies, the industry acts resourcefully and a lot is done to the save the ecological environment.

  1. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  2. Understanding Eco-innovation and Green Business Models

    DEFF Research Database (Denmark)

    Andersen, Maj Munch

    2014-01-01

    Eco-innovation is considered a still more important competitive strategy to maintain production in highcost economies such as the Danish one. Within the studies of economics of technological change only little research has been undertaken on the dynamics of eco-innovation. Rigorous statistics...... technologies which has taken a starting pointin the environmental effects of varies technologies. The seven categories are:1. Curative eco-innovations - add-on (clean-up, recycling and resource handling)2. Integrated continuous process and product eco-innovations (cleaner production and products)3. User...... and definitions of ecoinnovationare lacking leading to much confusion and methodologically weak empirical analyses. This paperseeks to remedy this by offering a definition and taxonomy of eco-innovations and discussing theimplications for green business model thinking, bringing in examples of Danish successful...

  3. From an eco-industrial park towards an eco-city : a case study in Suzhou, China

    NARCIS (Netherlands)

    Yu, Chang; Dijkema, Gerard P. J.; de Jong, Martin; Shi, Han

    2015-01-01

    As eco-industrial park policies have been in place for years, many mature eco-industrial parks tend to acquire more than just industrial functions and become new urban districts. We investigated this development and conducted empirical research in Suzhou Industrial Park, to obtain insight in how a

  4. Experimental characterisation of Polyethylene Terephthalate (PET) bottle Eco-bricks

    International Nuclear Information System (INIS)

    Taaffe, Jonathan; O’Sullivan, Seán; Rahman, Muhammad Ekhlasur; Pakrashi, Vikram

    2014-01-01

    Highlights: • Characterisation of a novel “Eco-brick” by recycling PET bottles and plastic waste. • Eco-bricks have properties for possible uses in construction. • Consistent manufacturing of Eco-bricks demonstrated to be possible. • Weight of Eco-bricks has a nearly linear relationship with mechanical strength. • Light passage and sound reduction potential of Eco-bricks shown to be good. - Abstract: This paper addresses the issue of recycling waste plastic by considering the feasibility of use of Eco-bricks for constructional purposes. The Eco-bricks are formed by packing plastic within Polyethylene Terephthalate (PET) bottles. Guidelines were provided for the construction of Eco-bricks. Experiments were carried out to characterise some of the properties of these bricks. Compression test, sound insulation assessment and light transmission were considered in this regard and compared with traditional construction materials and conditions. Possible applications of Eco-bricks were discussed. The paper presents the first attempt to characterise these bricks and the results encourage future use of them to a significantly wider extent and for various purposes

  5. Non-iridescent structural colors from uniform-sized SiO2 colloids

    Science.gov (United States)

    Topçu, Gökhan; Güner, Tuğrul; Demir, Mustafa M.

    2018-05-01

    Structural colors have recently attracted interest from diverse fields of research due to their ease of fabrication and eco-friendliness. These types of colors are, in principle, achieved by periodically arranged submicron-diameter colloidal particles. The interaction of light with a structure containing long-range ordered colloidal particles leads to coloration; this usually varies depending on the angle of observation (iridescence). However, the majority of the applications demand constant color that is independent of the viewing angle (non-iridescence). In this work, silica colloids were obtained using the Stöber method at different sizes from 150 to 300 nm in an alcoholic dispersion. The casting of the dispersion on a substrate leaves behind a photonic crystal showing a colorful iridescent film. However, centrifugation and redispersion of the SiO2 particles into fresh solvent may cause the formation of small, aggregated silica domains in the new dispersion. The casting of this dispersion allows for the development of photonic glass, presumably due to the accumulation of aggregates showing stable colloidal film independent of viewing angle. Moreover, depending on the size of the silica colloids, non-iridescent photonic glasses with various colors (violet, blue, green, and orange) are obtained.

  6. Determinants of eco-efficiency in the Chinese industrial sector.

    Science.gov (United States)

    Fujii, Hidemichi; Managi, Shunsuke

    2013-12-01

    This study measures productive inefficiency within the context of multi-environmental pollution (eco-efficiency) in the Chinese industrial sector. The weighted Russell directional distance model is applied to measure eco-efficiency using production technology. The objective is to clarify how external factors affect eco-efficiency. The major findings are that both foreign direct investment and investment for pollution abatement improve eco-efficiency as measured by air pollutant substances. A levy system for wastewater discharge improves eco-efficiency as measured by wastewater pollutant substances. However, an air pollutant levy does not significantly affect eco-efficiency as measured by air pollutants. Copyright © 2013 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados con los lentes de contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but 10 hours ...

  8. The innovative application studty on eco-packaging design and materials

    Directory of Open Access Journals (Sweden)

    Cui Yong Min

    2016-01-01

    Full Text Available The paper solves the increasingly deteriorate environmental problems by positively exploring how to utilize and develop eco-packaging design reasonably. The paper explores an effective method that combines eco-packaging and environmental protection materials, hoping to define the sustainable development road of packaging design. The paper is centered on the design application of eco-packaging and environmental protection materials, applies and analyzes the method to obtain innovative design requirements and development tendency of eco-packaging design by analyzing status and significance of eco-packaging design, combining with the development and main types of eco-packaging packaging materials, and based on the achievements acquired by eco-packaging and environmental protection materials. Meanwhile, the paper also reveals mutual dependence and mutual promotion of eco-packaging design and eco-packaging materials.

  9. Sustainable packaging: from eco-efficiency to eco-effectiveness

    DEFF Research Database (Denmark)

    Niero, Monia; Boas, Simon H.; Olsen, Stig Irving

    2014-01-01

    According to Verghese et al (2012) sustainable packaging should be: effective in delivering its functional requirements, efficient in its use of materials, energy, and water throughout its life cycle, cyclic in its use of renewable materials and recoverability at end-of-life, and safe for people...... and the natural environment. Companies in the packaging sector have traditionally been using the Life Cycle Assessment (LCA) methodology to fulfill these requirements. However, being inspired by the eco-efficiency principle, LCA aims to reduce the negative environmental footprint of human activities by optimizing...... and emissions can be taken up as nutrients by other processes instead of reducing the amount of waste as eco-efficiency advocates. From a company point of view, LCA and C2C are complementary approaches to develop sustainable andinnovative solutions for packaging, see Figure 1. We will illustrate the challenges...

  10. User's guide to the biosphere code ECOS

    International Nuclear Information System (INIS)

    Kane, P.; Thorne, M.C.

    1984-10-01

    This report constitutes the user's guide to the biosphere model ECOS and provides a detailed description of the processes modelled and mathematical formulations used. The FORTRAN code ECOS is an equilibrium-type compartmental biosphere code. ECOS was designed with the objective of producing a general but comprehensive code for use in the assessment of the radiological impact of unspecified geological repositories for radioactive waste. ECOS transforms the rate of release of activity from the geosphere to the rate of accumulation of weighted committed effective dose equivalent (dose). Both maximum individual dose (critical group dose) and collective dose rates may be computed. (author)

  11. Eco-marketing in industrial enterprise activities

    OpenAIRE

    N.M. Chupryna

    2015-01-01

    The aim of the article. The aim of the article is determination of the areas of industrial enterprise’s development and detection of the specificity of their activity in terms of environmental priorities. The results of the analysis. The analysis of the research and publications of the leading scholars on the eco-marketing’s problem was conducted. The main factors of eco-marketing’s mechanism use were considered. Eco-marketing was determined as an important tool of the enterprises’ modern ...

  12. The Economic Value of Corporate Eco-Efficiency

    International Nuclear Information System (INIS)

    Guenster, N.; Derwall, J.; Bauer, R.; Koedijk, K.

    2006-08-01

    This study adds new insights to the long-running corporate environmental-financial performance debate by focusing on the concept of eco-efficiency. Using a new database of eco-efficiency ratings, we analyze the relation between eco-efficiency and financial performance from 1997 to 2004. We report that eco-efficiency relates positively to operating performance and market value. Moreover, our results suggest that the market's valuation of environmental performance has been time variant, which may indicate that the market incorporates environmental information with a drift. Although environmental leaders initially did not sell at a premium relative to laggards, the valuation differential increased significantly over time. Our results have implications for company managers, who evidently do not have to overcome a tradeoff between eco-efficiency and financial performance, and for investors, who can exploit environmental information for investment decisions

  13. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  14. Color del iris e hipoacusia en el Síndrome de Waardenburg. Pinar del Río, Cuba Color of the iris and hypoacusis in Waardenburg Syndrome. Pinar del Rio, Cuba

    Directory of Open Access Journals (Sweden)

    Fidel Castro Pérez

    2012-06-01

    Full Text Available Introducción: Aunque se han descrito hipoacusia neurosensorial y cambios de color en el iris, la relación entre estos no ha sido estudiada previamente. Objetivos: Describir y analizar la posible asociación de la hipoacusia y profundidad de ésta con el color del iris en una familia afectada con el síndrome, lo que constituiría un nuevo aporte al conocimiento del Síndrome de Waardenburg (SW. Material y Método: Se realizó un estudio de casos, observacional, transversal y descriptivo con algunos aspectos analíticos en personas con SW del Municipio Sandino. Se utilizaron las medidas de resumen para variables cualitativas y la prueba de X² para medir asociación al 95 % de certeza. Resultados: 15 individuos presentaron hipoacusia neurosensorial de diferentes distribución e intensidad, con predominio de los ojos pardos y azules bilaterales. Se detectó mayor frecuencia de individuos hipoacúsicos entre los que tenían ojos azules con asociación entre las dos variables (X²= 6,47, gl = 1; p = 0.01. La intensidad de la hipoacusia fue mayor entre los individuos con ojos azules (85.7 % con hipoacusia severa o profunda 3 veces superior que en los otros colores de los ojos. Conclusiones: Existe relación entre el color azul del iris y la presencia de la hipoacusia y mayor intensidad de esta última en individuos con SW.Background: Although sensorineural hearing loss and iris pigmentary changes have been described, the association between these two elements has not been previously studied. Objectives: to describe and analyze the possible association of hypoacusis and the intensity of this with the color of the iris in a family suffering from this syndrome; which will constitute a new contribution to the understanding of Waardenburg Syndrome (WS. Material and Method: an observational, cross-sectional and descriptive case-study was carried out having some analytic aspects in people suffering from WS in Sandino municipality, Pinar del Rio. Measures

  15. An R&D Management Framework for Eco-Technology

    OpenAIRE

    Hideki Kobayashi; Masahiro Kato; Yukishige Maezawa; Kenji Sano

    2011-01-01

    Although research and development (R&D) affects new value-added creation, including that related to environmental aspects, there is little literature dealing with the integration of R&D management and eco-value. Here, eco-value of technology is defined as the advantage of environmental competitiveness in the market. This paper proposes a framework of R&D management of eco-technology (RDMOET), consisting of: (1) future research for sustainability; (2) making an original eco-theme p...

  16. Diagnostic Indication for Venous Echo-Doppler of the Lower Limbs in the Diagnosis of Thromboembolic; Indicacion de eco-Doppler venosa de extremidades inferiores en el diagnostico de la enfermedad tromboembolica ante una sospecha de tromboembolismo pulmonar

    Energy Technology Data Exchange (ETDEWEB)

    Bolado, A. G.; Barcena, M. V.; Cura, J. L. del; Gorrno, O.; Grande, D. [Hospital de Basurto. Bilbao (Spain)

    2003-07-01

    To study the effectiveness of Doppler echography in the deep venous system of the lower limbs for deep venous thrombosis detection in patients suspected of having pulmonary thromboembolism. There were received 341 consecutive suspected pulmonary thromboembolism patients, all of whom were emergency room attended. All were submitted to CT pulmonary angiography in order to evaluate thrombus presence in the pulmonary tree. Without knowing the results of the previous exploration, we studied 301 of the patients using Doppler echography in deep venous system of the lower limbs in order to evaluate thrombus presence. In the group of CT-detected pulmonary thromboembolism patients, the percentage of Doppler echography-detected deep venous thrombosis was 46.3%, while in the group of non-detected patients this percentage decreased to 4.7%. Additional deep venous system exploration in clinically suspected pulmonary thiolcarbamate patients is useful, since it can increase the detection rate of venous thromboembolic disease, thereby leading to early treatment and prevention of the disease's manifestation in the lungs. Realization of Doppler echography is especially beneficial in those patients who exhibit no factors which predispose them to thromboembolic disease, as well as in patients who have previously had venous thrombosis. This exploration account for 4.7% of non-detected pulmonary embolism patients being added to the ranks of those with thromboembolic disease, an important percentage when taking into consideration the high pulmonary thromboembolism morbimortality rate. (Author) 30 refs.

  17. Eliminación de ruido impulsivo en imágenes a color, utilizando interpolación con funciones de base radial

    Directory of Open Access Journals (Sweden)

    Jaime Alberto Echeverri Arias

    2011-05-01

    Full Text Available Este documento presenta un método para suprimir ruido impulsivo enimágenes a color, utilizando interpolación a través de funciones de baseradial. Este es un problema clásico en múltiples aplicaciones en diferentesáreas, su origen radica en mecanismos de captación de datosdefectuosos, que generan errores a intervalos variados de tiempo en lasseñales de entrada.Se comparan los resultados obtenidos con el método propuesto, frente alos algoritmos clásicos no lineales, como el filtrado por la mediana, la mediay el de outlier. En todos los escenarios probados, los resultados fueronmás eficaces con el método propuesto. El algoritmo demostró ser robustofrente a grandes volúmenes de ruido en el caso de prueba. Los resultadosfueron analizados a través del error cuadrado medio (ECM y Peak Signalto Noise Ratio (PSNR que son dos métricas de uso común para compararla calidad entre dos imágenes luego de un proceso de restauración. Sealcanzó un ECM de 14 y un PSNR de 35.8 db sobre la imagen de Lenna a512x512 pixeles con un porcentaje de pixeles ruido del 40%.

  18. Wait watchers: the application of a waiting list active management program in ambulatory care.

    Science.gov (United States)

    de Belvis, Antonio Giulio; Marino, Marta; Avolio, Maria; Pelone, Ferruccio; Basso, Danila; Dei Tos, Gian Antonio; Cinquetti, Sandro; Ricciardi, Walter

    2013-04-01

    This study describes and evaluates the application of a waiting list management program in ambulatory care. Waiting list active management survey (telephone call and further contact); before and after controlled trial. Local Health Trust in Veneto Region (North-East of Italy) in 2008-09. Five hundred and one people on a 554 waiting list for C Class ambulatory care diagnostic and/or clinical investigations (electrocardiography plus cardiology ambulatory consultation, eye ambulatory consultation, carotid vessels Eco-color-Doppler, legs Eco-color-Doppler or colonoscopy, respectively). Active list management program consisting of a telephonic interview on 21 items to evaluate socioeconomic features, self-perceived health status, social support, referral physician, accessibility and patients' satisfaction. A controlled before-and-after study was performed to evaluate anonymously the overall impact on patients' self-perceived quality of care. The rate of patients with deteriorating healthcare conditions; rate of dropout; interviewed degree of satisfaction about the initiative; overall impact on citizens' perceived quality of care. 95.4% patients evaluated the initiative as useful. After the intervention, patients more likely to have been targeted with the program showed a statistically significant increase in self-reported quality of care. Positive impact of the program on some dimensions of ambulatory care quality (health status, satisfaction, willingness to remain in the queue), thus confirming the outstanding value of 'not to leave people alone' and 'not to leave them feeling themselves alone' in healthcare delivery.

  19. Influence of red mud on soil microbial communities: Application and comprehensive evaluation of the Biolog EcoPlate approach as a tool in soil microbiological studies.

    Science.gov (United States)

    Feigl, Viktória; Ujaczki, Éva; Vaszita, Emese; Molnár, Mónika

    2017-10-01

    Red mud can be applied as soil ameliorant to acidic, sandy and micronutrient deficient soils. There are still knowledge gaps regarding the effects of red mud on the soil microbial community. The Biolog EcoPlate technique is a promising tool for community level physiological profiling. This study presents a detailed evaluation of Biolog EcoPlate data from two case studies. In experiment "A" red mud from Ajka (Hungary) was mixed into acidic sandy soil in soil microcosms at 5-50 w/w%. In experiement "B" red mud soil mixture was mixed into low quality subsoil in a field experiment at 5-50 w/w%. According to average well color development, substrate average well color development and substrate richness 5-20% red mud increased the microbial activity of the acidic sandy soil over the short term, but the effect did not last for 10months. Shannon diversity index showed that red mud at up to 20% did not change microbial diversity over the short term, but the diversity decreased by the 10th month. 30-50% red mud had deteriorating effect on the soil microflora. 5-20% red mud soil mixture in the low quality subsoil had a long lasting enhancing effect on the microbial community based on all Biolog EcoPlate parameters. However, 50% red mud soil mixture caused a decrease in diversity and substrate richness. With the Biolog EcoPlate we were able to monitor the changes of the microbial community in red mud affected soils and to assess the amount of red mud and red mud soil mixture applicable for soil treatment in these cases. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Middle cerebral artery vasospasm: transcranial color-coded duplex sonography versus conventional nonimaging transcranial Doppler sonography.

    Science.gov (United States)

    Swiat, Maciej; Weigele, John; Hurst, Robert W; Kasner, Scott E; Pawlak, Mikolaj; Arkuszewski, Michal; Al-Okaili, Riyadh N; Swiercz, Miroslaw; Ustymowicz, Andrzej; Opala, Grzegorz; Melhem, Elias R; Krejza, Jaroslaw

    2009-03-01

    To prospectively compare accuracies of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of middle cerebral artery (MCA) vasospasm. Prospective blinded head-to-head comparison TCD and TCCS methods using digital subtraction angiography (DSA) as the reference standard. Department of Radiology in a tertiary university health center in a metropolitan area. Eighty-one consecutive patients (mean age, 53.9 +/- 13.9 years; 48 women). The indication for DSA was subarachnoid hemorrhage in 71 patients (87.6%), stroke or transient ischemic attack in five patients (6.2%), and other reasons in five patients (6.2%). The MCA was graded as normal, narrowed 50% using DSA. The accuracy of ultrasound methods was estimated by total area (Az) under receiver operator characteristic curve. To compare sensitivities of ultrasound methods, McNemar's test was used with mean velocity thresholds of 120 cm/sec for the detection of less advanced, and 200 cm/sec for the more advanced MCA narrowing. Angiographic MCA narrowing 50% in 10 of 135 arteries. Accuracy of TCCS was insignificantly higher than that of TCD in the detection of 50% narrowing, total Az for mean velocity being 0.83 +/- 0.05, 0.77 +/- 0.05, and 0.95 +/- 0.02, 0.86 +/- 0.08, respectively. Sensitivity of TCCS at commonly used threshold of 120 cm/sec for less advanced MCA spasm was significantly better than that of TCD at similar specificity, 55% vs. 39%, p = 0.038, whereas at a threshold of 200 cm/sec used for more advanced spasm, sensitivities and specificities of both methods were not different. The accuracy of TCCS and TCD is similar, but TCCS is more sensitive than TCD in the detection of MCA spasm. Sensitivity of both techniques in the detection of mild and more advanced spasm using 120 cm/sec and 200 cm/sec thresholds, respectively, is poor; however, a larger sample is required to increase precision of our sensitivity estimates.

  1. Quantitative comparison of disc rim color in optic nerve atrophy of compressive optic neuropathy and glaucomatous optic neuropathy.

    Science.gov (United States)

    Nakano, Eri; Hata, Masayuki; Oishi, Akio; Miyamoto, Kazuaki; Uji, Akihito; Fujimoto, Masahiro; Miyata, Manabu; Yoshimura, Nagahisa

    2016-08-01

    The purpose was to investigate an objective and quantitative method to estimate the redness of the optic disc neuroretinal rim, and to determine the usefulness of this method to differentiate compressive optic neuropathy (CON) from glaucomatous optic neuropathy (GON). In our study there were 126 eyes: 40 with CON, 40 with normal tension glaucoma (NTG), and 46 normal eyes (NOR). Digital color fundus photographs were assessed for the redness of disc rim color using ImageJ software. We separately measured the intensity of red, green, and blue pixels from RGB images. Three disc color indices (DCIs), which indicate the redness intensity, were calculated through existing formulas. All three DCIs of CON were significantly smaller than those of NOR (P  -6 dB), in which the extent of retinal nerve fiber layer thinning is comparable, the DCIs of mild CON were significantly smaller than those of mild NTG (P optic disc color was useful in differentiating early-stage CON from GON and NOR.

  2. Concept of heat-induced inkless eco-printing.

    Science.gov (United States)

    Chen, Jinxiang; Wang, Yong; Xie, Juan; Meng, Chuang; Wu, Gang; Zu, Qiao

    2012-07-01

    Existing laser and inkjet printers often produce adverse effects on human health, the recycling of printing paper and the environment. Therefore, this paper examines the thermogravimetry curves for printer paper, analyzes the discoloration of paper using heat-induction, and investigates the relationship between paper discoloration and the heat-inducing temperature. The mechanism of heat-induced printing is analyzed initially, and its feasibility is determined by a comparative analysis of heat-induced (laser ablation) printing and commercial printing. The innovative concept of heat-induced inkless eco-printing is proposed, in which the required text or graphics are formed on the printing paper via yellowing and blackening produced by thermal energy. This process does not require ink during the printing process; thus, it completely eliminates the aforementioned health and environmental issues. This research also contributes to related interdisciplinary research in biology, laser technology, photochemistry, nano-science, paper manufacturing and color science. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. ECO-SUSTAINABLE DEVELOPMENT AND ROMANIAN TOURISM

    Directory of Open Access Journals (Sweden)

    MARIANA BĂLAN

    2014-05-01

    Full Text Available In a changing world, the development of eco-sustainable tourism is manifested in the form of interaction of elements compatible with each other in various dimensions: economic, environmental, human, technological, environmental, ethical, etc. Through eco-sustainable tourism aims to satisfy the present needs of tourists in favor and not in detrimental to the interests of future generations, along with educating them in the spirit of reducing negative environmental impacts. This paper provides a brief overview of the tourism - ecology - sustainable development relationship, by highlighting the evolutionary theoretical considerations regarding the concept of tourism, the need for sustainable tourism development, the ecology as a priority in the development and integration of tourism activities within the coordinates the eco-sustainable development. It also discusses the main indicators used to characterize the tourism activities in Romania in the context of eco-sustainable development.

  4. The analysis of ink jet printed eco-font efficiency

    Directory of Open Access Journals (Sweden)

    Rastko Milošević

    2016-07-01

    Full Text Available Utilization of eco-font for office printing is one of sustainable, “green” printing concepts, which besides obvious economic benefits, as a result has a certain effect on environmental sustainability as well. The fundamental problem that this practice faces is decreased quality of text printed using eco-fonts comparing to those printed with regular fonts. The aim of this research is eco-font efficiency estimation, i.e. determination of toner usage reduction level of ink jet printed documents typed with this font type, as well as estimation of the extent humans perceive differences between text printed with eco-font and the one printed by its „non-eco“ equivalent. Combining instrumental measuring method and digital image analysis, it was found that this simple principle (eco-font utilization enables substantial toner usage reduction for an ink jet printing system, while visual test showed that visual experience of text printed using eco-font is sufficient. In addition, awareness of benefits that eco-font utilization brings, change users’ attitude towards eco-font quality.

  5. The UV-VIS spectrophotometry applied to color and stability study in colored mortars

    Directory of Open Access Journals (Sweden)

    Alejandre, F. J.

    1999-06-01

    Full Text Available In the field of methodologies for color studying, a research of it has been done on colored mortars by applying uv-vis spectrophotometry, instrumental technique which can be used for solid materials works, and previously applied to building materials study. Results obtained show that the mentioned technique permits to evaluate quantitatively and qualitatively colors in an easy and objective way, besides nowadays advantages of the instrumental analysis: digital color register, computerized data processing, and precision and exactness increment in chromatic comparisons.

    Dentro de las metodologías existentes para el estudio del color, se ha realizado una investigación del mismo en morteros coloreados por medio de la espectrofotometría UV-VIS, técnica instrumental que es adaptable al trabajo con materiales sólidos, y que ha sido aplicada anteriormente en el estudio de diversos materiales de construcción. Los resultados obtenidos muestran cómo la citada técnica permite además de evaluar cualitativamente y cuantitativamente los colores de forma sencilla y objetiva, el disponer de las ventajas que conlleva actualmente el análisis instrumental: registro digital del color, tratamiento informatizado de datos y aumento de precisión y exactitud en las comparaciones cromáticas.

  6. Homogenization of Doppler broadening in spin-noise spectroscopy

    Science.gov (United States)

    Petrov, M. Yu.; Ryzhov, I. I.; Smirnov, D. S.; Belyaev, L. Yu.; Potekhin, R. A.; Glazov, M. M.; Kulyasov, V. N.; Kozlov, G. G.; Aleksandrov, E. B.; Zapasskii, V. S.

    2018-03-01

    The spin-noise spectroscopy, being a nonperturbative linear optics tool, is still reputed to reveal a number of capabilities specific to nonlinear optics techniques. The effect of the Doppler broadening homogenization discovered in this work essentially widens these unique properties of spin-noise spectroscopy. We investigate spin noise of a classical system—cesium atoms vapor with admixture of buffer gas—by measuring the spin-induced Faraday rotation fluctuations in the region of D 2 line. The line, under our experimental conditions, is strongly inhomogeneously broadened due to the Doppler effect. Despite that, optical spectrum of the spin-noise power has the shape typical for the homogeneously broadened line with a dip at the line center. This fact is in stark contrast with the results of previous studies of inhomogeneous quantum dot ensembles and Doppler broadened atomic systems. In addition, the two-color spin-noise measurements have shown, in a highly spectacular way, that fluctuations of the Faraday rotation within the line are either correlated or anticorrelated depending on whether the two wavelengths lie on the same side or on different sides of the resonance. The experimental data are interpreted in the frame of the developed theoretical model which takes into account both kinetics and spin dynamics of Cs atoms. It is shown that the unexpected behavior of the Faraday rotation noise spectra and effective homogenization of the optical transition in the spin-noise measurements are related to smallness of the momentum relaxation time of the atoms as compared with their spin-relaxation time. Our findings demonstrate abilities of spin-noise spectroscopy for studying dynamic properties of inhomogeneously broadened ensembles of randomly moving spins.

  7. Eco-Labeled Seafood: Determinants for (Blue Green Consumption

    Directory of Open Access Journals (Sweden)

    Malin Jonell

    2016-09-01

    Full Text Available Eco-certification has become an increasingly popular market-based tool in the endeavor to reduce negative environmental impacts from fisheries and aquaculture. In this study, we aimed at investigating which psychological consumer characteristics influence demand for eco-labeled seafood by correlating consumers’ stated purchasing of eco-labeled seafood to nine variables: environmental knowledge regarding seafood production, familiarity with eco-labels, subjective knowledge, pro-environmental self-identification, sense of personal responsibility, concern for negative environmental impacts from seafood production, perceived consumer effectiveness, gender and education. Questionnaires were distributed to consumers in Stockholm, Sweden, and the data were tested with multiple regression analysis using linear modeling and model averaging (n = 371. Two variables were the best predictors of stated purchasing of eco-labeled seafood: (i recognition and understanding of eco-labels for seafood (Marine Stewardship Council, Fish for Life, Aquaculture Stewardship Council and KRAV; and (ii concern for negative environmental impacts associated with seafood production. Meanwhile, consumer environmental knowledge was a weaker predictor. Results from this study suggest that strengthening the emotional component of consumer decision-making and improving the level of consumer familiarity with seafood eco-labels could stimulate more pro-environmental seafood consumption.

  8. How To Develop Ngorongoro As An Eco Tourism Destination : Eco Tourism In Ngorongoro

    OpenAIRE

    Londo, Amwewa; Londo, Amwewa

    2008-01-01

    In the third World Countries there is a need to develop and promote Tourism industry. Tourism Sector needs to be promoted to push economic development and increase the number of employments This research aims to find out whether eco-tourism sector at Ngorongoro Conservation area generates suistanable profit to local people. Qualitative reasearch was used to analyze eco-tourism value that leads to better understanding of different supports methods being used by government to local peopl...

  9. Quantitative Assessment of Synovial Vascularity Using Contrast-Enhanced Power Doppler Ultrasonography: Correlation with Histologic Findings and MR Imaging Findings in Arthritic Rabbit Knee Model

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Shin, Myung Jin; Kim, Seong Moon; Kim, Namkug; Suh, Sang Hyun; Suh, Jin Suck

    2008-01-01

    To validate contrast-enhanced power Doppler ultrasonography (PD US) for the evaluation of synovial vascularity in an arthritic rabbit knee model in correlation with MR and histological findings. Power Doppler ultrasonography was performed for carrageenin-induced arthritic left knee and control right knee of 13 rabbits, first without and then with sonic contrast agent enhancement (Levovist, Schering, Berlin Germany), followed by gadolinium-enhanced MR imaging. Synovial vascularity was quantitatively assessed by calculating the color pixel area in power Doppler sonography using a computer-aided image analysis program and by grading the enhancement on MR images: grade 1, enhancement of knee joint is less than one-third of the area; grade 2, one-third to two-thirds enhancement; and grade 3, more than two-thirds enhancement. Microvessel density (MVD) was measured on slides stained immunohistochemically for CD31 antigen for histological assessment. The mean area of color pixels in PD US changed from 4.37 to 16.42 mm 2 in the arthritic knee after enhancement (p 2 in the control knee (p 0.05). Sonic contrast-enhanced PD US improves the visualization of synovial vascularity and allows quantitative measurement in experimentally induced rabbit arthritic knees

  10. Multichannel wireless ECoG array ASIC devices.

    Science.gov (United States)

    DeMichele, Glenn A; Cogan, Stuart F; Troyk, Philip R; Chen, Hongnan; Hu, Zhe

    2014-01-01

    Surgical resection of epileptogenic foci is often a beneficial treatment for patients suffering debilitating seizures arising from intractable epilepsy [1], [2], [3]. Electrodes placed subdurally on the surface of the brain in the form of an ECoG array is one of the multiple methods for localizing epileptogenic zones for the purpose of defining the region for surgical resection. Currently, transcutaneous wires from ECoG grids limit the duration of time that implanted grids can be used for diagnosis. A wireless ECoG recording and stimulation system may be a solution to extend the diagnostic period. To avoid the transcutaneous connections, a 64-channel wireless silicon recording/stimulating ASIC was developed as the electronic component of a wireless ECoG array that uses SIROF electrodes on a polyimide substrate[4]. Here we describe two new ASIC devices that have been developed and tested as part of the on-going wireless ECoG system design.

  11. Doppler evaluation of valvular stenosis

    International Nuclear Information System (INIS)

    Kisslo, J.; Krafchek, J.; Adams, D.; Mark, D.B.

    1986-01-01

    One of the reasons why use of Doppler echocardiography is growing rapidly is because of its utility in detecting the presence of valvular stenosis and in estimating its severity. Detection of the presence of stenotic valvular heart disease using Doppler echocardiography was originally described over 10 years ago. It has been demonstrated that Doppler blood velocity data could be used to estimate the severity of a stenotic lesion. This chapter discusses the evaluation of valvular stenois using Doppler

  12. Desarrollo de un software de gestión de color para la industria cerámica

    Directory of Open Access Journals (Sweden)

    Martín, A.

    2014-04-01

    Full Text Available Not availableHoy en día contamos con una gran variedad de dispositivos para crear e imprimir imágenes, por eso es tan difícil ver un documento creado con un dispositivo, en otro diferente. La forma más eficaz de responder a este problema, es usar un Sistema de Gestión del Color (CMS. Cada dispositivo posee un modo particular de procesar el color. Con un Sistema de Gestión de Color, es posible controlar la reproducción de una imagen en diferentes dispositivos. Por lo tanto, la Gestión del Color describe todo el sistema que se utiliza para una comunicación cromática precisa entre un dispositivo y otro, y está basado en un software.

  13. Eco-modernism, a third way for tomorrow's energy?

    International Nuclear Information System (INIS)

    Anon.

    2017-01-01

    Considering climate warming as an immediate threat for humanity, ecologists from the Eco-modernism movement not only approve but call for the presence of nuclear power in the energy mix. For them nuclear energy is a mature low-carbon energy that can be used to combine all renewable energies more efficiently. NGO like 'Environmental Progress', 'Energy for Humanity' or 'Save the Nukes' back the Eco-modernism movement. The Eco-modernism movement gathers unconventional ecologists who consider that modern technologies by using the eco-system more efficiently than previous technologies did, are a powerful tool to reduce the global impact of humane activities on the biosphere. The Eco-modernism movement is for agricultural intensification, the use of GMO, waste recycling and for increasing urbanization. (A.C.)

  14. Business sustainability performance measurement: Eco-ratio analysis

    Directory of Open Access Journals (Sweden)

    Collins C. Ngwakwe

    2016-12-01

    Full Text Available Eco-aware customers and stakeholders are demanding for a measurement that links environmental performance with other business operations. To bridge this seemingly measurement gap, this paper suggests ‘Eco-Ratio Analysis’ and proposes an approach for conducting eco-ratio analysis. It is argued that since accounting ratios function as a tool for evaluating corporate financial viability by management and investors, eco-ratio analysis should be brought to the fore to provide a succinct measurement about the linkage between environmental performance and conventional business performance. It is hoped that this suggestion will usher in a nuance debate and approach in the teaching, research and practice of environmental management and sustainability accounting

  15. Eco friendly expectations and limitations in daycare

    DEFF Research Database (Denmark)

    Husted, Mia

    This presentation elaborates on expectations and limitations of eco-friendly pedagogical responses to the sustainability crisis. The pedagogical perspectives on eco-friendly responses originates from an action research project involving pedagogues in day care centers and teachers at a University ...... College in Denmark. As part of the project they were asked to explore, elaborate and develop new pedagogical actions and perspectives related to future relationships between human beings and our common nature......This presentation elaborates on expectations and limitations of eco-friendly pedagogical responses to the sustainability crisis. The pedagogical perspectives on eco-friendly responses originates from an action research project involving pedagogues in day care centers and teachers at a University...

  16. The Cognitive Doppler.

    Science.gov (United States)

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  17. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  18. Probability of malignancy in non-palpable thyroid nodules. Predictive value of color Doppler ultrasound and cytological correlation

    International Nuclear Information System (INIS)

    Perez Espinosa Sebastian; Pineda Ordonez, Diego; Garcia, Sandra; Costilla, Mariela

    2011-01-01

    Objective: To evaluate the diagnostic accuracy of ultrasound and Doppler criteria in the differentiation of malignant nodules, using cytological diagnosis as standard reference. Material and Method: Prospective observational study in 200 patients, between March-September 2008, assessed for known thyroid nodular disease using FNA. The probability of malignancy was categorized as low (0-3), intermediate (4-7) or high (greater than 7). The procedures were performed using Medison Sonoline ultrasound equipment, with a linear transducer (7.5 MHz), and the aspiration was performed with a 25 G needle and sent to cytology immediately. A single sample was needed in 88% of cases. Results: Approximately 96% of the nodules that went to cytology were categorized as low-grade, 3% as intermediate and 1% as high, without significant differences (p>0.5) when compared with the ultrasound score. Sonographic features indicating a high probability of malignancy were found in 2% (n=5) of cases, and the diagnosis was confirmed by cytology in 2 cases. Malignancy criteria such as size (>1 cm), irregular contours, solid echo structure, calcifications, and intranodal Doppler showed variable sensitivity and specificity (S: 32-44% and E: 28-55%) with overlapping confidence intervals within lesions of intermediate and low probability. Low probability lesions showed isoechogenicity, regular contours, lack of calcifications and intralesional Doppler, for a negative predictive value of 62-77%. Conclusion: Our results suggest that overlapping sonographic features between benign and malignant nodules requires final cytological diagnosis in most cases, given the safety of the cytological technique and the short waiting time.

  19. ECO-INDUSTRIAL PARK - A TOOL FOR SUSTAINABLE DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    BUGNAR NICOLETA GEORGETA

    2013-07-01

    Full Text Available Local communities embracing the concept of Eco-industrial park are looking for some additional benefits for all the interested parties – both public and private: higher economic efficiency, the increase of competitivity by applying last minute technologies, generation of additional revenues through positive regulations at the community level, the creation of jobs, solving the conflict between economy and environment, diminishing the demand on the county infrastructure, decreasing the effects of pollution, using energy from regenerating sources and replacement materials. Communities and enterprises creating Eco-industrial parks will have common grounds for industrial development, which is much more competitive, more efficient and much cleaner than traditional industrial parks. Moreover, the new business niches will be open to recruitment or new incubators. Eco-industrial parks represent a special category compared to industrial parks, a category which is different from the classical ones due to the fact that they are designed in such a way so that they promote the collaboration between companies in order to reuse recyclable materials and green energy sources. A long-term vision must reflect the focus on the creation of collaboration networks between firms and the fact that an Eco-industrial park should be a business community, not only a mathematical sum of companies located in the same geographical area. The quality, continuity and interconnection of economic flows within the firms of an Eco-industrial park are important characteristics for the success of Eco-industrial networks. The following discussion tackles the way in which an Eco-industrial park is set-up: creating and implementing an Eco-industrial park in accordance with the principles of circular economy or transforming an already existing industrial park into an Eco- industrial park. The quality, the continuity, the number of interconnected firms, the flows of resources and the

  20. ECOS: sorption, dose, consumption and miscellaneous data values

    International Nuclear Information System (INIS)

    Kane, P.

    1984-10-01

    This report describes the nature of the data stored within the program ECOS, lists the values currently used and references the sources used. Also included are the element-specific equilibrium distribution coefficients (Ksub(D)) which are held in a data file external to ECOS. Nuclide-specific decay constants and dose factors are presented, as are certain plant- and animal-specific data not included in external files. Several miscellaneous items of data stored within ECOS are described. None of the data stored within ECOS are accessible to the user. (author)

  1. Optimization of some eco-energetic systems

    International Nuclear Information System (INIS)

    Purica, I.; Pavelescu, M.; Stoica, M.

    1976-01-01

    An optimization problem of two eco-energetic systems is described. The first one is close to the actual eco-energetic system in Romania, while the second is a new one, based on nuclear energy as primary source and hydrogen energy as secondary source. The optimization problem solved is to find the optimal structure of the systems so that the objective functions adopted, namely unitary energy cost C and total pollution P, to be minimum at the same time. The problem can be modelated with a bimatrix cooperative mathematical game without side payments. We demonstrate the superiority of the new eco-energetic system. (author)

  2. Shedding Light on Eco-Innovation in Tourism: A Critical Analysis

    Directory of Open Access Journals (Sweden)

    Maria-del-Mar Alonso-Almeida

    2016-12-01

    Full Text Available The recent global increase in the competitiveness of tourism has made the implementation of eco-innovations a differentiating element among both the destinations and companies in the sector, with quality management and contribution to sustainable development being increasingly valued. However, the eco-innovations that have been developed and implemented in tourist industries have rarely been studied. In this study, the eco-innovations that have been developed and implemented by 57 tourism businesses worldwide are analysed. The identified eco-innovations are classified by using different qualitative methodologies. The obtained results shed light on the limited development of eco-innovations in the tourism industry and the industry focuses mainly on product eco-innovations. Several examples by the tourist sub-industry and types of eco-innovation are analysed. Furthermore, this study provides practical information about measures that both businesses and governmental organisations can adopt to promote eco-innovation in the sector.

  3. Enabling Eco-Friendly Choices by Relying on the Proportional-Thinking Heuristic

    Directory of Open Access Journals (Sweden)

    Cleotilde Gonzalez

    2013-01-01

    Full Text Available Ecological (eco taxes are promising mechanisms to enable eco-friendly decisions, but few people prefer them. In this study, we present a way in which eco-tax options may be communicated to general public to encourage their payment. Our implementation (called “information presentation” takes advantage of the non-linear relationship between eco-tax payments and CO2 emissions and the human reliance on the proportional-thinking heuristic. According to the proportional-thinking heuristic, people are likely to prefer a small eco-tax increase and judge larger eco-tax increases to cause proportionally greater CO2 emissions reductions. In an online study, participants were asked to choose between eco-tax increases in two problems: In one, a smaller eco-tax increase resulted in greater CO2 emissions reduction, while in the other, a smaller tax increase resulted in lesser CO2 emissions reduction. Although the larger eco-tax increase did not reduce CO2 emissions the most, across both problems, people judged larger eco-tax increases to cause proportionally greater reductions in CO2 emissions and preferred smaller tax increases. Thus, eco-tax policies would benefit by presenting information in terms of eco-tax increases, such that smaller eco-tax increases (which are more attractive and are likely to be chosen by people cause greater CO2 emissions reductions.

  4. Doppler flowmetry in preeclampsia.

    Science.gov (United States)

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  5. Evaluating Eco-Innovation of OECD Countries with Data Envelopment Analysis

    Science.gov (United States)

    Mavi, Reza Kiani; Standing, Craig

    2016-01-01

    Government regulations require businesses to improve their processes and products/services in a green and sustainable manner. For being environmentally friendly, businesses should invest more on eco-innovation practices. Firms eco-innovate to promote eco-efficiency and sustainability. This paper evaluates the eco-innovation performance of…

  6. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  7. ENTREPRENEURIAL ECO-SYSTEMS & REGIONAL ALLIANCES

    Directory of Open Access Journals (Sweden)

    Joe ENGLISH

    2015-05-01

    Full Text Available The study of universities and their role in enterprise development, support and education is very mature. However when Isenberg coined the term ‘entrepreneurial ecosystem’ and suggested that higher education was one of the key foundation blocks of a regional eco-system it threw open the concept of the university having a wider role in the overall business, economic and civic life of a region. What is this wider role, and how do the universities themselves view their place in this evolving entrepreneurial eco-system? How do they fit into Regional Alliances set up to build regional economic development? This paper introduces two pilot Alliances that have been recently formed using both the education institutes and the wider eco-system to drive Innovation and Graduate Employability (The SHIP and REAL Alliances.

  8. Triple helix interactions for eco-innovation

    DEFF Research Database (Denmark)

    Hermann, Roberto Rivas; Riisgaard, Henrik; Remmen, Arne

    the role of science parks in promoting eco-innovation. This study uses qualitative data gathered in two units of analysis: Panama Canal Authority and City of Knowledge Science Park. The study examines how Triple Helix interactions have built the regional system of eco-innovation at the Panama Canal...

  9. Comprasion of ovarian stromal blood flow measured by color Doppler ultrasonography in polycystic ovary syndrome patients and healthy women with ultrasonographic evidence of polycystic.

    Science.gov (United States)

    Ozdemir, Ozhan; Sari, Mustafa Erkan; Kalkan, Dilek; Koc, Esra Meltem; Ozdemir, Seyda; Atalay, Cemal Resat

    2015-04-01

    To compare ovarian stromal artery blood flows measured by Doppler ultrasonography of polycystic ovary syndrome (PCOS) patients and healthy women with polycystic ovarian image in ultrasonography. Forty-two patients diagnosed with PCOS according to the criteria of 2003 Rotterdam Concencus Conferance on PCOS and 38 healthy volunteers with polycystic ovarian image in ultrasonography were included in the study. Ovarian volumes and ovarian stromal artery blood flows were measured by 3-dimensional (3-D) ultrasonography and Doppler ultrasonography in all patients. In patients with PCOS, ovarian stromal artery pulsatility index (PI) and resistivity index (RI) were found significantly different from healthy women with polycystic ovarian image in ultrasonography (p ovarian volumes were found significantly higher in patients with PCOS (p ovarian volumes and ovarian stromal artery resistivity indices. Ovarian stromal artery Doppler examination could have an importance to explain the pathophysiology of PCOS, but there are few publications in the literature about PCOS and the details of ovarian stromal artery Doppler parameters in patients with polycystic ovarian image only. We conclude that Doppler ultrasonography findings of PCOS patients might be helpful in understanding the clinical follow-up and etiology of the disease.

  10. Modificações da hemodinâmica fetal pelo estímulo sonoro: avaliação pela dopplervelocimetria colorida Vibro-acoustic stimulation induced hemodynamic fetal changes assessed by color doppler

    Directory of Open Access Journals (Sweden)

    Francisco Mauad Filho

    1999-04-01

    Full Text Available Objetivos: verificar se ocorrem ou não alterações hemodinâmicas na aréria cerebral média (ACM aferido pela dopplervelocimetria colorida após realização de um estímulo sonoro. Métodos: trinta fetos de gestantes consideradas clinicamente normais com idade gestacional igual ou superior a 28 semanas foram submetidos a um estímulo sonoro. Examinamos as alterações da velocidade sangüínea na ACM fetal por meio do índice de resistência e da freqüência cardíaca fetal, pelo doppler colorido, antes e depois do estímulo acústico. Resultados: a média da freqüência cardíaca fetal (FCF antes do estímulo sonoro foi de 142,41 batimentos por minuto (bpm com desvio padrão de 9,01 e faixa de variação de 122 a 162 bpm. Após o estímulo sonoro, a média da FCF foi de 159,44 bpm com desvio padrão de 15,49, com faixa de variação de 130 a 187 bpm (pPurpose: to determine the possible occurrence of hemodynamic changes in the middle cerebral artery of the fetus (MCA using color doppler after vibro-acoustic stimulation. Methods: thirty fetuses from pregnant women considered to be clinically normal, with a gestational age of 28 weeks or more were submitted to vibro-acoustic stimulation. We examined the changes in blood flow rate in the middle cerebral artery of the fetus on the basis of resistance index (RI and fetal heart rate (FHR by color doppler before and after the sound stimulus. Results: mean FHR before vibro-acoustic stimulation was 142.41 beats per minute (bpm with a standard deviation of 9.01 and a range of 122 to 162 bpm. After stimulation, mean FHR was 159.44 bpm with a standard deviation of 15.49 and a range of 130 to 187 bpm (p<0.01. Mean RI in the MCA of the fetuses was 75.89% (range: 64 to 91% before the experiment. After the vibro-acoustic stimulation, mean RI was 66.93% (range: 47 to 83%; p < 0.01. Conclusions: we observed that a sound stimulus provokes the well-known immediate and significant elevation of FHR and a

  11. SUSTAINABLE ECONOMIC GROWTH AND ECO-EFFICIENCY

    Directory of Open Access Journals (Sweden)

    Mariana\tLUPAN

    2015-06-01

    Full Text Available The current economic and social contexts have brought forth the issues regarding growth and sustainability. The concept of growth has always been linked to an increase in consumption levels, and this inevitably led to pressures on the environment and on the resources that support human activity. Given these circumstances, the question whether we can avoid an environmental disaster while maintaining economic growth, has become more stringent. We chose to approach this aspect by examining the concept of eco-efficiency, a concept that embodies aspects of both economic efficiency and environmental efficiency. Eco-efficiency can be regarded as the effectiveness with which resources are used in order to create products and services that satisfy human needs. Based on this idea, the last decade has produced an increasing number of studies on eco-efficiency and how it can be measured and implemented in the production of goods and services, but also in the field regarding demand patterns. An analysis regarding the aspects of eco-efficiency at the macro level of the Romanian economy is in line with the current environmental concerns, thus I have chosen to cover these questions, as well as the evolution of the locale economy towards a more sustainable development. The outcome of the examined aspects shows that, in spite of an increase in eco-efficiency levels, energy and material consumption and emissions have increased. This raises the question if measuring economic and environmental efficiency by reporting to the GDP value is becoming obsolete and if there is a need to revaluate eco-efficiency indicators in order to measure the transition to a greener and more sustainable development from different points of view.

  12. Doppler radar flowmeter

    Science.gov (United States)

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  13. EcoMark: Evaluating Models of Vehicular Environmental Impact

    DEFF Research Database (Denmark)

    Guo, Chenjuan; Ma, Mike; Yang, Bin

    2012-01-01

    The reduction of greenhouse gas (GHG) emissions from transporta- tion is essential for achieving politically agreed upon emissions re- duction targets that aim to combat global climate change. So-called eco-routing and eco-driving are able to substantially reduce GHG emissions caused by vehicular...... the vehicle travels in. We develop an evaluation framework, called EcoMark, for such environmental impact models. In addition, we survey all eleven state-of-the-art impact models known to us. To gain insight into the capabilities of the models and to understand the effectiveness of the EcoMark, we apply...

  14. The Influence of Eco-water Retrieved by Quantitative Remote Sensing on Runoff in Upper Minjiang River Basin

    Directory of Open Access Journals (Sweden)

    Jin Huang

    2016-07-01

    Full Text Available Remote sensing quantitative retrieval of ecological water (eco-water has been foundational in systemic and quantitative research for water resources. Eco-water resource levels indicate conservation ability for the eco-water layer and influence of this on precipitation transformation and runoff regulation. The remote sensing quantitative inversion retrieved the MEC (Modulus of eco-water Conservation of the Upper Minjiang River Basin study area in 1994 and 2001, and combined with climate data between 1990 and 2005, the influence of conservation water on the eco-water layer on runoff was then analyzed. Results revealed significant efficacy for flood control and water supply during the drought from the hydrologic cycle of ecowater. Thus protection and restoration of the eco-water layer for flood and drought prevention are crucial.    Influencia del agua ecológica en la escorrentía de la cuenca alta del río Minjiang medida a través de teledetección cuantitativa   Resumen El sondeo remoto del agua ecológica (del inglés Eco-water, agua conservada en la superficie terrestre es indispensable en la investigación sistemática y cuantitativa de las fuentes de agua. Los niveles de suministros de agua ecológica indican la capacidad de conservación de la capa de agua ecológica y la influencia de esta en la transformación de precipitación y la regulación de escorrentía. La inversión cuantitativa por sondeo remoto estableció el Módulo de Conservación de Agua Ecológica (MEC, del inglés Modulus of Eco-Water Conservation para el área de estudio en la cuenca alta del río Minjiang entre 1994 y 2001, y combinada con la información climática de entre 1990 y 2005, se analizó la influencia de conservacion de agua en la capa ecoacuática. Los resultados mostraron una gran eficacia en el control de inundaciones y en el suministro de agua durante la sequía a lo largo del ciclo hidrológico. Por esta razón, la protección y restauración de la

  15. Eco-Material Selection for Auto Bodies

    Energy Technology Data Exchange (ETDEWEB)

    Mayyas, Ahmad T [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Omar, Mohammed [Masdar Institute of Science & Technology; Hayajneh, Mohammed T. [Jordan University of Science and Technology

    2017-09-25

    In the last decades, majority of automakers started to include lightweight materials in their vehicles to meet hard environmental regulations and to improve fuel efficiency of their vehicles. As a result, eco-material selection for vehicles emerged as a new discipline under design for environment. This chapter will summarize methods of eco-material selections for automotive applications with more emphasis into auto-bodies. A set of metrics for eco-material selection that takes into account all economic, environmental and social factors will be developed using numerical and qualitative methods. These metrics cover products' environmental impact, functionality and manufacturability, in addition to the economic and societal factors.

  16. Umberto Eco : olemise piire kombates / Marina Grishakova

    Index Scriptorium Estoniae

    Grišakova, Marina, 1961-

    2004-01-01

    Arvustus: Eco, Umberto. Eilse päeva saar / tõlkinud Merike Pau. Tallinn : Eesti Raamat, 2003 ; Eco, Umberto. Baudolino / itaalia keelest tõlkinud [ja järelsõna:] Ülar Ploom. Tallinn : Varrak, 2003

  17. Spatial weighting of Doppler reactivity feedback

    International Nuclear Information System (INIS)

    Carew, J.F.; Diamond, D.J.; Todosow, M.

    1977-12-01

    The spatial weighting of the local Doppler feedback implicit in the determination of the core Doppler feedback reactivity has been investigated. Using a detailed planar PDQ7-II PWR model with local fuel-temperature feedback, the core Doppler spatial weight factor, S, has been determined for various control patterns and power levels. Assuming power-squared weighting of the local Doppler feedback, a simple analytic expression for S has been derived and, based on comparison with the PDQ7-II results, provides a convenient and accurate representation of the Doppler spatial weight factor. The sensitivity of these results to variations in the fuel rod heat transfer coefficients, fuel loading and the magnitude of the Doppler coefficient has also been evaluated. The dependence of the local Doppler coefficient on moderator temperature, boron concentration and control rod density has been determined and found to be weak. Selected comparisons with vendor analyses have been made and indicate general agreement

  18. Eco2 Cities : Ecological Cities as Economic Cities

    OpenAIRE

    Suzuki, Hiroaki; Dastur, Arish; Moffatt, Sebastian; Yabuki, Nanae; Maruyama, Hinako

    2010-01-01

    This book provides an overview of the World Bank's Eco2 cities : ecological cities as economic cities initiative. The objective of the Eco2 cities initiative is to help cities in developing countries achieve a greater degree of ecological and economic sustainability. The book is divided into three parts. Part one describes the Eco2 cities initiative framework. It describes the approach, be...

  19. Snapshots from a leading eco-city

    DEFF Research Database (Denmark)

    Mehlsen, Camilla

    2009-01-01

    The government of Singapore wants to make Singapore the leading Eco-city in Asia. Professor Kim Chuan Goh explains why this might be an achievable goal.......The government of Singapore wants to make Singapore the leading Eco-city in Asia. Professor Kim Chuan Goh explains why this might be an achievable goal....

  20. [Changes of renal blood flow during organ-associated foot reflexology measured by color Doppler sonography].

    Science.gov (United States)

    Sudmeier, I; Bodner, G; Egger, I; Mur, E; Ulmer, H; Herold, M

    1999-06-01

    Using colour Doppler sonography blood flow changes of the right kidney during foot reflexology were determined in a placebo-controlled, double-blind, randomised study. 32 healthy young adults (17 women, 15 men) were randomly assigned to the verum or placebo group. The verum group received foot reflexology at zones corresponding to the right kidney, the placebo group was treated on other foot zones. Before, during and after foot reflexology the blood flow of three vessels of the right kidney was measured using colour Doppler sonography. Systolic peak velocity and end diastolic peak velocity were measured in cm/s, and the resistive index, a parameter of the vascular resistance, was calculated. The resistive index in the verum group showed a highly significant decrease (p foot reflexology. There was no difference between men and women and no difference between smokers and non-smokers. Verum and placebo group significantly differed concerning alterations of the resistive index both between the measuring points before versus during foot reflexology (p = 0.002) and those during versus after foot reflexology (p = 0.031). The significant decrease of the resistive index during foot reflexology in the verum group indicates a decrease of flow resistance in renal vessels and an increase of renal blood flow. These findings support the hypothesis that organ-associated foot reflexology is effective in changing renal blood flow during therapy.

  1. Proposal for the Evaluation of Eco-Efficient Concrete

    Directory of Open Access Journals (Sweden)

    Taehyoung Kim

    2016-07-01

    Full Text Available The importance of environmental consequences due to diverse substances that are emitted during the production of concrete is recognized, but environmental performance tends to be evaluated separately from the economic performance and durability performance of concrete. In order to evaluate concrete from the perspective of sustainable development, evaluation technologies are required for comprehensive assessment of environmental performance, economic performance, and durability performance based on a concept of sustainable development called the triple bottom line (TBL. Herein, an assessment method for concrete eco-efficiency is developed as a technique to ensure the manufacture of highly durable and eco-friendly concrete, while minimizing both the load on the ecological environment and manufacturing costs. The assessment method is based on environmental impact, manufacturing costs, and the service life of concrete. According to our findings, eco-efficiency increased as the compressive strength of concrete increased from 21 MPa to 40 MPa. The eco-efficiency of 40 MPa concrete was about 50% higher than the eco-efficiency of 24 MPa concrete. Thus eco-efficiency is found to increase with an increasing compressive strength of concrete because the rate of increase in the service life of concrete is larger than the rate of increase in the costs. In addition, eco-efficiency (KRW/year was shown to increase for all concrete strengths as mixing rates of admixtures (Ground Granulated Blast furnace Slag increased to 30% during concrete mix design. However, when the mixing rate of admixtures increased to 40% and 60%, the eco-efficiency dropped due to rapid reduction in the service life values of concrete to 74 (year/m3 and 44 (year/m3, respectively.

  2. CONSERVACIÓN POSCOSECHA DE TOMATE DE CÁSCARA (Physalis ixocarpa Brot. ex Horm. CON Y SIN CÁLIZ

    Directory of Open Access Journals (Sweden)

    Oscar Cruz-Álvarez

    2012-01-01

    Full Text Available El objetivo del trabajo fue observar la influencia del cáliz en la vida poscosecha de frutos de tomate de cáscara bajo diferentes temperaturas de almacenamiento (4 y 20 °C con presencia y ausencia del cáliz. El diseño experimental fue completamente al azar con estructura factorial 2 x 2. Se determinaron la tasa de respiración, la producción de etileno, la acidez titulable, la pérdida de peso, los sólidos solubles totales, la vitamina C, la firmeza, el color y la clorofila total. Los tratamientos con presencia del cáliz tuvieron el mayor contenido de clorofila total, con valores que fluctuaron de 0.147 a 0.161 μg.100g, a los 0 y 20 días después de cosecha (ddc, manteniendo la brillantez, cromaticidad y tonalidad del color sin cambios importantes. Los frutos almacenados a temperatura de 4 °C mantuvieron (P ≤ 0.05 el comportamiento de la firmeza y los sólidos solubles, en tanto que los frutos con 20 °C presentaron 5 % de pérdida de peso. Asimismo, el contenido de clorofila fue mayor con valores 0.142 y 0.158 μg 100 g, lo que coincidió con lo observado para los componentes de color. Los cambios manifestados en firmeza, pérdida de peso, contenido de clorofila y color estuvieron relacionados con las temperaturas de almacenamiento, más que con la presencia o ausencia del cáliz.

  3. Eco-ethology

    International Nuclear Information System (INIS)

    Krebs, J.R.; Davies, N.B.

    1981-01-01

    Eco-ethology is the science of the effects of animal behaviour on animal environment and the effects of animal environment on animal behaviour, with the purpose to find out how natural selection within this control loop has formed and molded animals. N. Tinbergen was the first to make experiments on the evolution of patterns of behaviour which are influenced not only by the evolution of species but also by their adaptation to a changing environment. R.H. MacArthur then introduced mathematical modelling for better clarification of the function and adoptive value of behavioural patterns. The book gives a detailed description of both methods and a successful attempt at a synthesis. In surveys and specific contribution, an exemplary outline of eco-ethology is presented, with information, ideas and reflections that are of interest both to teachers and students. The book is addressed to biologists, zoologists, ecologists, sociologists, and evolutionary biologists and to students of these disciplines. (orig.) [de

  4. Eco-design pilot project in China - Monsoon offer 2 upgrade

    Science.gov (United States)

    Thai, Roselyne; Liu, Guoguo

    2017-11-01

    During COP21, Schneider Electric has committed that 100% of our new products would be eco-designed to tackle climate change. Launched in 2015, this initiative ecoDesign WayTM was tested on some pilot projects. This project covers the first ecoDesign WayTM pilot in China on an overvoltage or under voltage protective device used in both residential and industrial sectors, called Monsoon. Under the name ecoDesign WayTM, a method and a process have been deployed. The 3 main ecoDesign WayTM phases are: phase 1 - Marketing & Technique handshake, Phase 2 - ecoDesign WayTM follow-up and Phase 3 - Marketing communication. During the project, EIME from Bureau Veritas CODDE and ecoDesign WayTM scorecard from EVEA consulting are two core tools for eco-design implementation. They are respectively used for life cycle assessment and eco-design performance comparison. Thanks to the approach, compared to previous range, pollution emissions and resource depletion along the whole life cycle of product have decreased (reduction of 55% for energy depletion and 85% for water depletion). Global warming potential has dramatically decreased by 98.4% and air pollution by 33%. Meanwhile, the recycling rate has been improved by 18%, and recycled PA is used. The ecoDesign WayTM scorecard is stored as referent document for any customer request. Moreover, customers can access RoHS certificate, REACh declaration, PEP and EoLI in Check a product, an online environmental data repository, available 24/7.

  5. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  6. Eco Logic signs deal to destroy Japanese PCB stocks

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    According to a recent announcement, Eco Logic of Rockwood, Ontario, has entered into a partnership with the Japanese companies Tokyo Boeki and Nippon Sharyo for the destruction of stockpiled PCB materials in Japan, using Eco Logic's non-incineration technology. The deal is reported to be worth about $50 million in revenues to Eco Logic, spread over the next few years. The agreement includes provisions for the Japanese companies to purchase, or manufacture under licence, a number of Eco Logic's gas phase chemical reduction processing units to serve the Japanese market. In exchange for exclusive rights to the Japanese market, Eco Logic will receive license fees and royalties of up to nine per cent for the use of its process. Eco Logic is currently building a demonstration unit under contract with the two Japanese companies. The Japanese PCB waste destruction market is estimated to be worth as much as $400 million. Incineration, the conventional form of disposal, is strongly opposed by local governments

  7. A method to validate quantitative high-frequency power doppler ultrasound with fluorescence in vivo video microscopy.

    Science.gov (United States)

    Pinter, Stephen Z; Kim, Dae-Ro; Hague, M Nicole; Chambers, Ann F; MacDonald, Ian C; Lacefield, James C

    2014-08-01

    Flow quantification with high-frequency (>20 MHz) power Doppler ultrasound can be performed objectively using the wall-filter selection curve (WFSC) method to select the cutoff velocity that yields a best-estimate color pixel density (CPD). An in vivo video microscopy system (IVVM) is combined with high-frequency power Doppler ultrasound to provide a method for validation of CPD measurements based on WFSCs in mouse testicular vessels. The ultrasound and IVVM systems are instrumented so that the mouse remains on the same imaging platform when switching between the two modalities. In vivo video microscopy provides gold-standard measurements of vascular diameter to validate power Doppler CPD estimates. Measurements in four image planes from three mice exhibit wide variation in the optimal cutoff velocity and indicate that a predetermined cutoff velocity setting can introduce significant errors in studies intended to quantify vascularity. Consistent with previously published flow-phantom data, in vivo WFSCs exhibited three characteristic regions and detectable plateaus. Selection of a cutoff velocity at the right end of the plateau yielded a CPD close to the gold-standard vascular volume fraction estimated using IVVM. An investigator can implement the WFSC method to help adapt cutoff velocity to current blood flow conditions and thereby improve the accuracy of power Doppler for quantitative microvascular imaging. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    2016-01-01

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  9. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  10. Estimating fruitpulp carotenoid content from shell color in gulupa (Passiflora edulis Sims

    Directory of Open Access Journals (Sweden)

    Germán Franco

    2013-07-01

    Full Text Available La gulupa (Passiflora edulis Sims es un fruto aceptado en mercados europeos; pero, su corta vida en poscosecha limita la comercialización. Por lo tanto, es necesario, caracterizar algunos atributos de la maduración, para que el fruto mantenga las mejores condiciones de calidad. La investigación tuvo como objetivo estimar, a partir de los cambios de color del fruto y de su edad, la evolución de los carotenoides, mediante el uso de modelos que predijeran esta relación. Se utilizaron frutos con edad conocida para determinar el color con base en el espacio CIE L*, a* y b*. La colorimetría confirmó que hay evolución apreciable a partir de los 84 días después de floración (DDF, con color morado oscuro hacia los 98 DDF y púrpura muy oscuro a los 105 DDF. En frutos madurados en la planta, se apreció disminución en la luminosidad (L*, mientras que en las coordenadas a* el valor aumentó y el b* disminuyó, cambios que definen el color del fruto. Se observó una tendencia similar en frutos cosechados a partir de los 91 DDF. Tanto en los frutos madurados en la planta como en los cosechados, el contenido de carotenoides se incrementó a medida que la senescencia del fruto avanzaba. Modelos de regresión permitieron estimar el contenido de carotenoides: uno múltiple, con las coordenadas de color como predictoras y el otro polinomial, basado en la edad del fruto.

  11. Who needs cream and sugar when there is eco-labeling? Taste and willingness to pay for "eco-friendly" coffee.

    Science.gov (United States)

    Sörqvist, Patrik; Hedblom, Daniel; Holmgren, Mattias; Haga, Andreas; Langeborg, Linda; Nöstl, Anatole; Kågström, Jonas

    2013-01-01

    Participants tasted two cups of coffee, decided which they preferred, and then rated each coffee. They were told (in lure) that one of the cups contained "eco-friendly" coffee while the other did not, although the two cups contained identical coffee. In Experiments 1 and 3, but not in Experiment 2, the participants were also told which cup contained which type of coffee before they tasted. The participants preferred the taste of, and were willing to pay more for, the "eco-friendly" coffee, at least those who scored high on a questionnaire on attitudes toward sustainable consumer behavior (Experiment 1). High sustainability consumers were also willing to pay more for "eco-friendly" coffee, even when they were told, after their decision, that they preferred the non-labeled alternative (Experiment 2). Moreover, the eco-label effect does not appear to be a consequence of social desirability, as participants were just as biased when reporting the taste estimates and willingness to pay anonymously (Experiment 3). Eco labels not only promote a willingness to pay more for the product but also lead to a more favorable perceptual experience of it.

  12. Who needs cream and sugar when there is eco-labeling? Taste and willingness to pay for "eco-friendly" coffee.

    Directory of Open Access Journals (Sweden)

    Patrik Sörqvist

    Full Text Available Participants tasted two cups of coffee, decided which they preferred, and then rated each coffee. They were told (in lure that one of the cups contained "eco-friendly" coffee while the other did not, although the two cups contained identical coffee. In Experiments 1 and 3, but not in Experiment 2, the participants were also told which cup contained which type of coffee before they tasted. The participants preferred the taste of, and were willing to pay more for, the "eco-friendly" coffee, at least those who scored high on a questionnaire on attitudes toward sustainable consumer behavior (Experiment 1. High sustainability consumers were also willing to pay more for "eco-friendly" coffee, even when they were told, after their decision, that they preferred the non-labeled alternative (Experiment 2. Moreover, the eco-label effect does not appear to be a consequence of social desirability, as participants were just as biased when reporting the taste estimates and willingness to pay anonymously (Experiment 3. Eco labels not only promote a willingness to pay more for the product but also lead to a more favorable perceptual experience of it.

  13. Development of Eco-Industry Sector

    OpenAIRE

    Mariana Ioviţu

    2012-01-01

    Measures to encourage development of Eco-industries represent an important part of the programs of many countries; analyses of different international organisms reveal a series of advantages of this sector for economy. According to OCDE “The environmental goods and services industry consists of activities which produce goods and services to measure, prevent, limit, minimize or correct environmental damage to water, air and soil, as well as problems related to waste, noise and Eco-systems”. Th...

  14. Doppler ultrasound monitoring technology.

    Science.gov (United States)

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  15. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...

  16. Burst Format Design for Optimum Joint Estimation of Doppler-Shift and Doppler-Rate in Packet Satellite Communications

    Directory of Open Access Journals (Sweden)

    Luca Giugno

    2007-05-01

    Full Text Available This paper considers the problem of optimizing the burst format of packet transmission to perform enhanced-accuracy estimation of Doppler-shift and Doppler-rate of the carrier of the received signal, due to relative motion between the transmitter and the receiver. Two novel burst formats that minimize the Doppler-shift and the Doppler-rate Cramér-Rao bounds (CRBs for the joint estimation of carrier phase/Doppler-shift and of the Doppler-rate are derived, and a data-aided (DA estimation algorithm suitable for each optimal burst format is presented. Performance of the newly derived estimators is evaluated by analysis and by simulation, showing that such algorithms attain their relevant CRBs with very low complexity, so that they can be directly embedded into new-generation digital modems for satellite communications at low SNR.

  17. Application of eco-economy regionalization in western China

    Science.gov (United States)

    Zhang, Xiaojun; Dong, Suocheng; Weihong, Yin

    2008-08-01

    Ecological economics crossed extensively with some disciplines such as ecology, geography, economics, etc in China. And it is promoting the relevant disciplines to develop effectively in depth fields. The key research direction of eco-economic regionalizing is eco-economic space pattern, rule of territorial differentiation and eco-economic topological optimization. Based on GIS spatial analyze, the article elaborates the main characteristics and the problems of every eco-economic zones, districts and regions with the comprehensive geographical statistic data. The western eco-economic regionalizing was delimited by analyzing the superposition for ecological environment value and human actives value, refer to the topography and administrative boundary between provinces and the cities, the attachment of the regionalizing plans and territorial the continuity. There have several main indexes used in the regionalizing and the results to show the main character of each region, which comprise precipitation, temperature, primary production potential, while the population carrying capacity, and the index of water resources, land resources, landscape degradation, urbanization, and economic development, etc. To each type of eco-economic region, there are other analyzes respectively from the social, economic, and natural environment aspects. The result shows that there does now have serious economic development in western China, while the environmental problem still cannot be ignored.

  18. Color Doppler Indices of Orbital Arterial Flow in End-Stage Renal Disease Patients; Are the Changes Related to Chronic Hemodialysis or Chronic Renal Failure?

    International Nuclear Information System (INIS)

    Rokni Yazdi, Hadi; Faraji, Safoura; Ahmadi, Farokhlegha; Shahmirzae, Reza

    2012-01-01

    Endothelial injury is a well-known complication in chronic kidney disease (CKD) and hemodialysis. One of the sites in which early vascular changes may be detected is the retina. Of course, these flow changes may not be detected in ophthalmologic exams, but it seems that color Doppler sonography of retinal arteries may be helpful in these cases. In previous studies on CKD patients who underwent chronic hemodialysis,hemodynamic changes were noted in retinal arteries, but no study has been performed to determine which of the two processes (CKD or chronic hemodialysis) can produce these changes. In this study, we tried to answer this question. Doppler ultrasonography of the orbital vasculature including the ophthalmic artery and the central retinal artery was carried out in 17 patients (34 eyes) with chronic renal failure (CRF) who underwent hemodialysis, 17 patients (34 eyes)with CRF without a history of hemodialysis and 17 normal patients (34 eyes). The peak systolic velocity (PSV), end diastolic velocity (EDV) and resistance index were measured excluding hypertensive, diabetic patients and patients with cardiovascular disease. The mean PSV and EDV were lower only in the ophthalmic artery of CRF patients irrespective of the history of hemodialysis (PSV was 35.2 in hemodialysis, 38.8 in CRF and 51.6 in normal patients, P value = 0.001 and EDV was 7.4, 9.4, 11.8, respectively, P value =0.001) with no significant difference in the resistance index of the ophthalmic artery and other parameters [EDV, PSV, Resistance Index (RI)] in the central retinal artery. The mean PSV and DSV in the ophthalmic artery were lower only in the ophthalmic artery of CRF patients regardless of the history of hemodialysis. No significant difference in the resistance index of the ophthalmic artery and other parameters (EDV, PSV) of the central retinal artery were noted between different groups. These findings suggest that microvascular disease and endothelial cell dysfunction of the orbital

  19. Use of ultrasound Doppler to determine tooth vitality in a discolored tooth after traumatic injury: its prospects and limitations

    Directory of Open Access Journals (Sweden)

    Yong-Wook Cho

    2014-02-01

    Full Text Available When a tooth shows discoloration and does not respond to the cold test or electric pulp test (EPT after a traumatic injury, its diagnosis can be even more difficult due to the lack of proper diagnostic methods to evaluate its vitality. In these case reports, we hope to demonstrate that ultrasound Doppler might be successfully used to evaluate the vitality of the tooth after trauma, and help reduce unnecessary endodontic treatments. In all three of the present cases, the teeth were discolored after traumatic injuries and showed negative responses to the cold test and EPT. However, they showed distinctive vital reactions in the ultrasound Doppler test during the whole observation period. In the first case, the tooth color returned to normal, and the tooth showed a positive response to the cold test and EPT at 10 wk after the injury. In the second case, the tooth color had returned to its normal shade at 10 wk after the traumatic injury but remained insensitive to the cold test and EPT. In the third case, the discoloration was successfully treated with vital tooth bleaching.

  20. Constraints in the Adoption of Eco Friendly Conservation Practices

    Directory of Open Access Journals (Sweden)

    L. Murali Krishnan

    2016-05-01

    Insect pest and diseases management, Lack of awareness of agro environmental problems and farmer’s attitude towards the Eco Friendly Conservation Practices are the major constraints in the adoption of Eco Friendly Conservation Practices.The study suggests educational, extension & training strategies for fostering the adopted of ECO friendly Conservation Practices.

  1. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  2. Eco-Efficiency Actions and Firm Growth in European SMEs

    Directory of Open Access Journals (Sweden)

    Elisenda Jové-Llopis

    2018-01-01

    Full Text Available This study investigates the effects of eco-efficiency actions on firm performance in terms of sales growth in an extensive sample of 11,336 small- and medium-sized enterprises (SMEs located in 28 European countries. Our empirical results suggest that not all eco-strategies are positively related to better performance, at least not in the short term. We found that European companies using renewable energies, and recycling or designing products that are easier to maintain, repair, or reuse, perform better. Those that aim to reduce water or energy pollution, however, seemed to show a negative correlation to firm growth. Our results also indicate that high investment in eco-strategies improves firm growth, particularly in new members that joined the EU from 2004 onwards. Finally, we observed a U-shaped relationship between eco-strategies and firm growth, which indicates that a greater breadth of eco-strategies is associated with better firm performance. However, few European SMEs are able to either invest heavily or undertake multiple eco-strategies, thus leaving room for policy interventions.

  3. [Research advances in eco-toxicological diagnosis of soil pollution].

    Science.gov (United States)

    Liu, Feng; Teng, Hong-Hui; Ren, Bai-Xiang; Shi, Shu-Yun

    2014-09-01

    Soil eco-toxicology provides a theoretical basis for ecological risk assessment of contaminated soils and soil pollution control. Research on eco-toxicological effects and molecular mechanisms of toxic substances in soil environment is the central content of the soil eco-toxicology. Eco-toxicological diagnosis not only gathers all the information of soil pollution, but also provides the overall toxic effects of soil. Therefore, research on the eco-toxicological diagnosis of soil pollution has important theoretical and practical significance. Based on the research of eco-toxicological diagnosis of soil pollution, this paper introduced some common toxicological methods and indicators, with the advantages and disadvantages of various methods discussed. However, conventional biomarkers can only indicate the class of stress, but fail to explain the molecular mechanism of damage or response happened. Biomarkers and molecular diagnostic techniques, which are used to evaluate toxicity of contaminated soil, can explore deeply detoxification mechanisms of organisms under exogenous stress. In this paper, these biomarkers and techniques were introduced systematically, and the future research trends were prospected.

  4. Reflexiones en torno a la ecoética y sus aportes en la época contemporánea

    Directory of Open Access Journals (Sweden)

    José Arlés Gómez Arévalo

    2014-01-01

    Full Text Available El presente artículo hace parte de la investigación adelantada por el Grupo Ciencia-Espiritualidad, que en su tercera fase denominada “Ecología-salud-formación integral”. Se realiza una aproximación epistémica a las potenciales correspondencias entre el pensamiento occidental y los grandes metarrelatos del lejano Oriente, con relación a los fundamentos de la ecoética, ciencia emergente, lo que responde en gran medida –en la complejidad del mundo contemporáneo– a los profundos desafíos en materia de objetivación de una nueva mirada sobre el hombre en su interrelación armónica con la naturaleza y el universo.

  5. Eco-industrial initiatives in Asia : issues and opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, A.S.F. [Industrial Ecology Asia Network, (China)

    2002-07-01

    This Power Point presentation discusses the impact of industry urban-suburban relocation. This relocation to industrial zones is on the rise in Asia, where there are now approximately 4,000 industrial estates, resulting from export-oriented businesses, cluster-based activities and collective management systems. Eco-industrial parks are zones that promote sustainable development through the combined benefits of environmental, social and economic initiatives. Eco-industrial parks enact environmental management laws and initiate eco-industrial development projects. Asia is diverse in access to natural resources, economics, politics, and level of development and access to natural resources. The paper describes how eco-business and a recycling-oriented economic society is being adopted in countries in Asia including China, Japan, Thailand, Philippines, Indonesia, Malaysia, Vietnam and India. tabs., figs.

  6. Study on the value of color Doppler ultrasound in evaluating the efficacy of neoadjuvant chemotherapy for breast cancer

    Directory of Open Access Journals (Sweden)

    Chao-Xi Li

    2016-05-01

    Full Text Available Objective: To explore the value of color Doppler flow imaging (CDFI in evaluating the efficacy of neoadjuvant chemotherapy (NCT for breast cancer. Methods: A total of 60 patients with breast cancer who were admitted in our hospital from January, 2015 to December, 2015 were included in the study. TC scheme was used for chemotherapy before operation, i.e. cyclophosphamide 600 mg/m2, docetaxel 75 mg/m2, IV. Three-week treatment was regarded as one course, for 2-4 weeks. After chemotherapy for 1-2 week, the operation was performed. CDFI was used to observe the lesion location, number, size, shape, boundary, internal echo, surrounding echo, rear echo, axillary lymph node, and the relation with the surrounding tissues. The lesion resistance index (RI was measured. Results: CDFI results showed that 3 were CF, 35 were PR, 20 were SD, and 2 were PD, with a diagnostic sensitivity of 80.6% and coincidence rate of 68.3%. After NCT, the length, width, thickness, area, and volume of the lesions were significantly reduced when compared with before NCT. The comparison of the evaluation of the boundary resolution and echo of the lesions by CDFI before and after NCT was statistically significant. The pathological results showed that 31 were effective, and 29 were invalid, among which RI in the effective group was significantly reduced when compared with before NCT, while RI in the invalid group was not significantly different from that before NCT. Conclusions: The efficacy evaluation of NCT by CDFI is highly consistent with the pathology. CDFI in evaluating the size, boundary, echo, and blood flow indicators of the lesions is of great scientificity and clinical application value.

  7. Efecto hemodinámico esplácnico de somatostatina y octreótido en cirróticos: Estudio con ultrasonografía Doppler Splanchnic hemodynamic effects of somatostatin and octreotide in cirrhotic patients: A Doppler ultrasonographic study

    Directory of Open Access Journals (Sweden)

    F. J. Fernández Pérez

    2008-09-01

    Full Text Available Objetivo: valoración ultrasonografica Doppler del efecto hemodinámico de la administración intravenosa de somatostatina y octreótido. Material y método: aleatorizamos a 45 cirróticos con varices esofágicas para recibir en una hora una infusión intravenosa de somatostatina (SOM, 250 µg, octreotido (OCT, 50 µg o placebo (PLA. Pretratamiento y a 15, 30, 45 y 60 minutos medimos velocidad media, índice de congestión, volumen de flujo y diámetro de la vena porta además del índice de resistencia en arteria mesentérica superior. Analizamos las concentraciones séricas de bradicinina y péptido intestinal vasoactivo (VIP en situación basal y a 30 y 60 minutos. Resultados: respecto de los valores basales tanto SOM como OCT provocaron un descenso significativo en la velocidad (-19,41 vs. -11.19% y flujo portal (-22,79 vs. -12,33%, con aumento del índice de congestión (+17,5 vs. +7,5% y del índice de resistencia arterial (+7,18 vs. +6,16% respecto de sus valores basales (p Aim: Doppler-ultrasound assessment of the splanchnic hemodynamic effects of intravenous somatostatin and octreotide administration. Material and method: forty-five cirrhotic patients with esophageal varices were randomized to receive 1-hour intravenous somatostatin (SOM, 250 µg, octreotide (OCT, 50 µg, or placebo (PLA. In baseline and at 15, 30, 45 and 60 minutes of infusion, mean velocity, congestion index, flow volume and diameter of the portal vein, as well as the superior mesenteric artery resistivity index, were measured. Plasma bradykinine and vasoactive intestinal peptide (VIP concentrations were also measured at baseline and at 30 and 60 minutes. Results: while placebo caused no changes in any of the venous and arterial parameters, SOM and OCT caused a sustained decrease in portal vein velocity (-19.41 vs. -11.19% and flow (-22.79 vs. -12.33%, and an increase in the congestion index (+17.5 vs. +7.5% and resistivity index of the superior mesenteric artery (+7

  8. Eco-efficient Agriculture: Concepts, Challenges, and Opportunities

    NARCIS (Netherlands)

    Keating, B.A.; Carberry, P.S.; Bindraban, P.S.; Asseng, S.; Meinke, H.B.; Dixon, J.

    2010-01-01

    Eco-efficiency in the simplest of terms is about achieving more with less—more agricultural outputs, in terms of quantity and quality, for less input of land, water, nutrients, energy, labor, or capital. The concept of eco-efficiency encompasses both the ecological and economic dimensions of

  9. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  10. Course Content for Life Cycle Engineering and EcoDesign

    DEFF Research Database (Denmark)

    Jerswiet, Jack; Duflou, Joost; Dewulf, Wim

    2007-01-01

    There is a need to create an awareness of Life Cycle Engineering and EcoDesign in Engineering students. Topics covered in an LCE/EcoDesign course will create an awareness of environmental impacts, especially in other design course projects. This paper suggests that an awareness of product impact...... upon the environment must be created at an early stage in undergraduate education. Deciding what to include in an LCE/EcoDesign Course can be difficult because there are many different views on the subject. However, there are more similarities than differences. All LCE/ EcoDesign Engineering courses...

  11. Who Needs Cream and Sugar When There Is Eco-Labeling? Taste and Willingness to Pay for “Eco-Friendly” Coffee

    Science.gov (United States)

    Sörqvist, Patrik; Hedblom, Daniel; Holmgren, Mattias; Haga, Andreas; Langeborg, Linda; Nöstl, Anatole; Kågström, Jonas

    2013-01-01

    Participants tasted two cups of coffee, decided which they preferred, and then rated each coffee. They were told (in lure) that one of the cups contained “eco-friendly” coffee while the other did not, although the two cups contained identical coffee. In Experiments 1 and 3, but not in Experiment 2, the participants were also told which cup contained which type of coffee before they tasted. The participants preferred the taste of, and were willing to pay more for, the “eco-friendly” coffee, at least those who scored high on a questionnaire on attitudes toward sustainable consumer behavior (Experiment 1). High sustainability consumers were also willing to pay more for “eco-friendly” coffee, even when they were told, after their decision, that they preferred the non-labeled alternative (Experiment 2). Moreover, the eco-label effect does not appear to be a consequence of social desirability, as participants were just as biased when reporting the taste estimates and willingness to pay anonymously (Experiment 3). Eco labels not only promote a willingness to pay more for the product but also lead to a more favorable perceptual experience of it. PMID:24324623

  12. Doppler-guided retrograde catheterization system

    Science.gov (United States)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  13. Combined analyses of costs, market value and eco-costs in circular business models : eco-efficient value creation in remanufacturing

    NARCIS (Netherlands)

    Vogtländer, J.G.; Scheepens, A.E.; Bocken, N.M.P.; Peck, D.P.

    2017-01-01

    Eco-efficient Value Creation is a method to analyse innovative product and service design together with circular business strategies. The method is based on combined analyses of the costs, market value (perceived customer value) and eco-costs. This provides a prevention-based single indicator for

  14. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography. Comparison with thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujimoto, Kohei; Watanabe, Hiroyuki; Hozumi, Takeshi; Otsuka, Ryo; Hirata, Kumiko; Yamagishi, Hiroyuki; Yoshiyama, Minoru; Yoshikawa, Junichi

    2004-01-01

    The usefulness of coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography to detect myocardial ischemia was compared with exercise thallium-201 single photon emission computed tomography (SPECT). Transthoracic Doppler echocardiography was performed in 110 patients with suspected coronary artery disease. Color Doppler signals of the left circumflex coronary artery flow in the apical four-chamber view were identified, and the velocities at rest and during hyperemia recorded for calculation of coronary flow reserve by the pulsed Doppler method. All patients underwent SPECT within 1 week of the transthoracic Doppler echocardiographic study. Coronary flow reserve in the left circumflex coronary artery was measured in 79 (72%) of 110 patients. SPECT revealed reversible perfusion defect in the left circumflex coronary artery territories in 12 of 69 patients excluding those with multivessel disease. Coronary flow reserve <2.0 had a sensitivity of 92% and specificity of 96% for reversible perfusion defect detected by SPECT. Noninvasive coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography can estimate myocardial ischemia in the left ventricular lateral regions. (author)

  15. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    International Nuclear Information System (INIS)

    Lee, Myoung Seok; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup; Park, Joong Shin; Jun, Jong Kwan

    2017-01-01

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP

  16. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok [Dept. of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Park, Joong Shin; Jun, Jong Kwan [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    2017-01-15

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP.

  17. Normal Doppler velocimetry of renal vasculature in Persian cats.

    Science.gov (United States)

    Carvalho, Cibele F; Chammas, Maria C

    2011-06-01

    Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n=50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17±13.46 cm/s and 0.38±0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15±0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17±9.40 cm/s and 0.54±0.07. The RA had a mean ESA of 1.12±1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828±0.296. The IA showed PSV and RI values of 32.16±9.33 cm/s and 0.52±0.06, respectively. The mean ESA of all IAs was 0.73±0.61 m/s(2). The calculated upper limit of the reference value was 2.0m

  18. Psychological predictors of eco-driving: A longitudinal study

    OpenAIRE

    Lauper Elisabeth; Moser Stephanie; Fischer Maja; Matthies Ellen; Kaufmann-Hayoz Ruth

    2015-01-01

    Eco-driving has well-known positive effects on fuel economy and greenhouse-gas emissions. Moreover, eco-driving reduces road-traffic noise, which is a serious threat to the health and well-being of many people. We investigated the psychological predictors of the adoption of eco-driving from the perspective of road-traffic noise abatement. The data came from 890 car drivers who participated in a longitudinal survey over four months. Specifically, we tested the effects of the intention to preve...

  19. Doppler ultrasound study of portal hemodynamics in patients with Gaucher disease

    Directory of Open Access Journals (Sweden)

    Šarenac-Kovač Radmila

    2015-01-01

    Full Text Available Gaucher disease is a lysosomal storage disorder caused by a deficiency of the enzyme glucocerebrosidase and characterized by the presence of pathological macrophages laden with glucosylceramide. Hepatosplenomegaly is a common manifestation of Gaucher disease, but symptomatic portal hypertension is rarely seen. The study included 20 untreated adult patients with Gaucher disease (non-neuronopathic type 1 diagnosed with the presence of Gaucher cells in the bone marrow, and 20 healthy subjects as controls. The examination of patients included color Doppler ultrasonography (pulsed Doppler mode, resistive index (RI and Doppler perfusion index (DPI using a Toshiba Xario ultrasound machine and a convex array probe PVT-375AX (1.9-6 MHz with the objective of analyzing portal hemodynamics. Results showed that all patients had enlarged liver and spleen, and their average sizes were significantly larger than those in the healthy controls (liver: 17.04 vs.14.02 cm; spleen: 22.2 vs. 10.74 cm. DPI values were significantly different between patients and controls (0.15 vs. 0.21. Considering DPI <0.15 indicates arterial liver hypoperfusion and hypoxia, it can be concluded that a number of patients had a problem with liver oxygenation, which may be linked to the high angiotensin-converting enzyme (ACE levels obtained in the patients (339.42 U/L, 10 times greater than in control subjects. Since ACE is a potent vasoconstrictor produced by spleen macrophages in Gaucher disease, we can suppose that elevated ACE is associated with effects on the blood vessels of the liver and spleen. [Projekat Ministarstva nauke Republike Srbije, br. 175056

  20. Eco-innovation: The opportunities for engineering design research

    DEFF Research Database (Denmark)

    O'Hare, Jamie Alexander; McAloone, Tim C.

    2014-01-01

    Eco-innovation is an approach that has the potential to deliver step change improvements in the environmental performance of products, but the uptake by industry to date has been disappointing. The paper presents a selective review of the academic literature, choosing examples of research that gi...... a flavour of the key trends and interesting topics that are emerging from the eco-innovation body of knowledge. We conclude by suggesting 10 areas where we see potential for the engineering design research community to contribute to the advancement of eco-innovation.......Eco-innovation is an approach that has the potential to deliver step change improvements in the environmental performance of products, but the uptake by industry to date has been disappointing. The paper presents a selective review of the academic literature, choosing examples of research that give...

  1. Eco-efficiency of grinding processes and systems

    CERN Document Server

    Winter, Marius

    2016-01-01

    This research monograph aims at presenting an integrated assessment approach to describe, model, evaluate and improve the eco-efficiency of existing and new grinding processes and systems. Various combinations of grinding process parameters and system configurations can be evaluated based on the eco-efficiency. The book presents the novel concept of empirical and physical modeling of technological, economic and environmental impact indicators. This includes the integrated evaluation of different grinding process and system scenarios. The book is a valuable read for research experts and practitioners in the field of eco-efficiency of manufacturing processes but the book may also be beneficial for graduate students.

  2. Diagnosis of right-sided varicocele: A retrospective comparative study between clinical examination, Doppler findings, US imaging and vascular anatomy at phlebography

    International Nuclear Information System (INIS)

    Cariati, Maurizio; Pieri, Stefano; Agresti, Paolo; Cariati, Massimiliano; Candito, Davide Fabio; Damiani, Giovanni; Marzano, Domenico

    2012-01-01

    Historically varicocele is diagnosed almost exclusively on the left side. The introduction of new imaging techniques has allowed the identification and characterization of right varicocele. This study aims to compare the diagnostic accuracy of various imaging techniques to data obtained using phlebography in the diagnosis of right varicocele. Patients treated for isolated right varicocele between 1992 and 2010 were retrospectively identified. Data from clinical examination, Doppler-USS, Color-Doppler-USS and Retrograde Phlebography were collected for each patient. 133 out of 4305 patients (3.1%) presented with an isolated right varicocele. 34 of these patients (25.6%) presented with palpable right varicocele. Doppler-USS identified various degrees of type I right venous reflux in 90 patients (67.7%). Phlebography showed venous reflux in all the patients (133), although with variability in terms of internal spermatic vein anatomy. Right varicocele is characterized by predictable anatomic features. Identification and characterization of these features is useful in guiding percutaneous treatment, allowing to optimize radiological display and reducing failure rate

  3. Diagnosis of right-sided varicocele: A retrospective comparative study between clinical examination, Doppler findings, US imaging and vascular anatomy at phlebography

    Energy Technology Data Exchange (ETDEWEB)

    Cariati, Maurizio, E-mail: davide.candito@libero.it [U.O.C. Radiologia, A.O. San Carlo Borromeo, via Pio II 3, 20153 Milan (Italy); Pieri, Stefano, E-mail: stefano.pieri@scamilloforlanini.rm.it [U.O.C. Diagnostica per Immagini Cardioscienze, A.O. San Camillo - Forlanini, Piazza Carlo Forlanini 1, 00151 Rome (Italy); Agresti, Paolo, E-mail: paolo.agresti@scamilloforlanini.rm.it [U.O.C. Diagnostica per Immagini Cardioscienze, A.O. San Camillo - Forlanini, Piazza Carlo Forlanini 1, 00151 Rome (Italy); Cariati, Massimiliano, E-mail: massimiliano.cariati@kcl.ac.uk [Department of Academic Oncology, King' s College London, 3rd Floor Bermondsey Wing, Guy' s Hospital, Great Maze Pond, London SE1 9RT (United Kingdom); Candito, Davide Fabio, E-mail: davide.candito@yahoo.it [Scuola di Specializzazione in Radiodiagnostica, Facoltà di Medicina e Chirurgia, Università degli studi di Milano, via Festa del Perdono 7, 20122 Milan (Italy); Damiani, Giovanni, E-mail: damiani_giovanni@libero.it [Scuola di Specializzazione in Radiodiagnostica, Facoltà di Medicina e Chirurgia, Università degli studi di Milano, via Festa del Perdono 7, 20122 Milan (Italy); Marzano, Domenico, E-mail: domenico.marzano@scamilloforlanini.rm.it [U.O.C. Urologia, A.O. San Camillo - Forlanini, Piazza Carlo Forlanini 1, 00151 Rome (Italy)

    2012-09-15

    Historically varicocele is diagnosed almost exclusively on the left side. The introduction of new imaging techniques has allowed the identification and characterization of right varicocele. This study aims to compare the diagnostic accuracy of various imaging techniques to data obtained using phlebography in the diagnosis of right varicocele. Patients treated for isolated right varicocele between 1992 and 2010 were retrospectively identified. Data from clinical examination, Doppler-USS, Color-Doppler-USS and Retrograde Phlebography were collected for each patient. 133 out of 4305 patients (3.1%) presented with an isolated right varicocele. 34 of these patients (25.6%) presented with palpable right varicocele. Doppler-USS identified various degrees of type I right venous reflux in 90 patients (67.7%). Phlebography showed venous reflux in all the patients (133), although with variability in terms of internal spermatic vein anatomy. Right varicocele is characterized by predictable anatomic features. Identification and characterization of these features is useful in guiding percutaneous treatment, allowing to optimize radiological display and reducing failure rate.

  4. Mammary blood supply in various diseases as evidenced by color Doppler sonography

    International Nuclear Information System (INIS)

    Kharchenko, V.P.; Rozhkova, N.I.; Zubovskij, G.A.; Medvedeva, N.A.

    1993-01-01

    Color dopplerosonography, traditional sonography, and mammography without contrast staining, as well as physical and pathomorphologic methods were used in examinations of the mammary glands of 76 women aged 18 to 65. Characteristic features of the blood supply to the gland were detected, and differential diagnostic criteria defined on the basis of these findings, to simplify differentiation between malignant and benign nodular formations and the diffuse changes in the mamma

  5. Roles of Eco-labeling in Fisheries Conservation and Sustainability

    Directory of Open Access Journals (Sweden)

    Olaniyi Alaba Olopade

    2017-06-01

    Full Text Available An important goal of fisheries management is to ensure that fish stocks are harvested at sustainable levels of fishing pressure. However, the classical maximum sustainable yield theory and its derivatives have not worked for fisheries management. A number of mitigating measures have been suggested of which eco -labeling is one. An ecolabel on a fish product is a distinctive mark or statement indicating that it has been harvested in compliance with preset sustainability standards. This paper examines eco labeling in fisheries as the new strategy to achieve fisheries conservation and sustainability. It emphasizes the importance of fish as critical food resources and new approach to fisheries management through the use of certification programs. It considers the benefits and problems that may accrue from eco-certification of fish harvesting and trade practices in fisheries. This paper, attention is focused on examining the likely option for development of eco-labeling scheme in Nigeria. The paper concludes that the increase awareness amongst stakeholders of the potential role of eco-labeling in conservation and sustainability tools should be established.   Keywords: Fisheries management, fish, conservation, eco-certification

  6. Umberto Eco og fortolkningens semiotik

    DEFF Research Database (Denmark)

    Frandsen, Finn

    1997-01-01

    En analyse af spørgsmålet om fortolkningens muligheder og grænser, sådan som det bliver formuleret og besvaret i den italienske semiotiker Umberto Ecos teoretiske forfatterskab. Problemstillingen - og dens transformationer hvad angår såvel metasprog, omfang, niveau og fokus - følges fra begyndelsen...... af 60'erne, hvor Eco er inspireret af fænomenologi og hermeneutik (f.eks. i Opera aperta), til begyndelsen af 90'erne, hvor han arbejder med tekstpragmatik og receptionssemiotik. (f.eks. i I limiti dell'interpretazione)...

  7. Enabling time-dependent uncertain eco-weights for road networks

    DEFF Research Database (Denmark)

    Hu, Jilin; Yang, Bin; Jensen, Christian S.

    2017-01-01

    travel costs. Based on the techniques above, different histogram aggregation methods are proposed to accurately estimate time-dependent GHG emissions for routes. Based on a 200-million GPS record data set collected from 150 vehicles in Denmark over two years, a comprehensive empirical study is conducted...... transportation. The foundation of eco-routing is a weighted-graph representation of a road network in which road segments, or edges, are associated with eco-weights that capture the GHG emissions caused by traversing the edges. Due to the dynamics of traffic, the eco-weights are best modeled as being time...... dependent and uncertain. We formalize the problem of assigning a time-dependent, uncertain eco-weight to each edge in a road network based on historical GPS records. In particular, a sequence of histograms is employed to describe the uncertain eco-weight of an edge at different time intervals. Compression...

  8. Congenital arterioportal fistulas: radiological treatment and color Doppler US follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Teplisky, Dario; Tincani, Eliana Uruena; Lipsich, Jose; Sierre, Sergio [Department of Interventional Radiology, Pichincha 1890, Buenos Aires (Argentina)

    2012-11-15

    Congenital intrahepatic arterioportal fistulas (APFs) are a rare cause of portal hypertension in children. Doppler US is a useful diagnostic imaging modality. Transarterial embolization is a minimally invasive and effective therapy allowing occlusion of the fistula and restoration of liver hemodynamics. To describe the clinical and radiologic findings, percutaneous treatment and role of D-US in the postembolization follow-up of children with APF. Between 2002 and 2011, four children with APF were treated. Initial diagnosis and follow-up was performed with D-US and confirmed by arteriography, followed by endovascular embolization in all patients. D-US demonstrated abnormal arterioportal communications in all patients. Six endovascular procedures were performed in these four children. In two children, no residual fistula was seen on D-US after the first procedure and symptoms resolved. In the other two children, D-US demonstrated residual flow through the fistula, with resolution of pathological D-US findings and symptoms after the second endovascular procedure. All four children were successfully treated and asymptomatic at the end of follow-up. The mean follow-up was 24 months. Interventional radiology has a key role in the treatment of congenital APF. D-US is a noninvasive and effective tool for the diagnosis and follow-up of these patients. (orig.)

  9. RFM-based eco-efficiency analysis using Takagi-Sugeno fuzzy and AHP approach

    International Nuclear Information System (INIS)

    Chen Ruiyang

    2009-01-01

    Eco-design is crucial to take environmental aspects into account in the phases of design. Few literature review that green product must meet market value. The development of models to predict market value is thus very useful because it can provide early eco-efficiency to the eco-design. For the eco-design engineer, when he tries to solve a customer feedback problem, he usually faces the eco-efficiency. There are, however, often other types of fuzziness uncertainty present, which are related to the quantity of eco-design conditions. In this paper, it is derived that analysis of eco-efficiency can be identified by using the RFM value for quantifying eco-design with Takagi-Sugeno fuzzy system on customer feedback problem. It clusters eco-efficiency into segments according to green product usages value expressed in terms of weighted RFM. This experiment examined the weighted RFM effect of overall average normalized, AHP and non-weighted for F1 metric. The experimental results show that the proposed methodology indeed can yield identification of higher quality

  10. [Applications of eco-environmental big data: Progress and prospect].

    Science.gov (United States)

    Zhao, Miao Miao; Zhao, Shi Cheng; Zhang, Li Yun; Zhao, Fen; Shao, Rui; Liu, Li Xiang; Zhao, Hai Feng; Xu, Ming

    2017-05-18

    With the advance of internet and wireless communication technology, the fields of ecology and environment have entered a new digital era with the amount of data growing explosively and big data technologies attracting more and more attention. The eco-environmental big data is based airborne and space-/land-based observations of ecological and environmental factors and its ultimate goal is to integrate multi-source and multi-scale data for information mining by taking advantages of cloud computation, artificial intelligence, and modeling technologies. In comparison with other fields, the eco-environmental big data has its own characteristics, such as diverse data formats and sources, data collected with various protocols and standards, and serving different clients and organizations with special requirements. Big data technology has been applied worldwide in ecological and environmental fields including global climate prediction, ecological network observation and modeling, and regional air pollution control. The development of eco-environmental big data in China is facing many problems, such as data sharing issues, outdated monitoring facilities and techno-logies, and insufficient data mining capacity. Despite all this, big data technology is critical to solving eco-environmental problems, improving prediction and warning accuracy on eco-environmental catastrophes, and boosting scientific research in the field in China. We expected that the eco-environmental big data would contribute significantly to policy making and environmental services and management, and thus the sustainable development and eco-civilization construction in China in the coming decades.

  11. Doppler color flow analysis of the uterine arteries before and after intrauterine device insertion: a prospective study.

    Science.gov (United States)

    de Souza, Marco Aurélio Martins; Geber, Selmo

    2006-02-01

    An intrauterine device (IUD) is one of the most frequently used methods of birth control around the world. Although a relationship between its use and menstrual disorders has been well documented, only a few studies have tried to show whether there are any vascular modifications. The aim of our study was to evaluate the influence of an IUD on uterine artery blood flow using Doppler assessment. A total of 100 patients selected for IUD use were prospectively evaluated with Doppler analysis before and 30 days after insertion. The resistive index (RI) and pulsatility index (PI) were used to evaluate uterine artery vascular resistance. Patients were allocated in 2 groups according to whether they were (group 2) or were not (group 1) lactating. The PI and RI of the patients in groups 1 and 2 before and after IUD insertion were not statistically significantly different (P = .298 and .23). When we compared uterine artery blood flow indices before and after IUD insertion for groups 1 and 2 separately, we observed in group 1 that the mean +/- SD PI values were 2.45 +/- 0.62 and 2.55 +/- 0.55 (P = .38) and the RI values were 0.87 +/- 0.08 and 0.87 +/- 0.06 (P = .88) before and after IUD insertion, respectively. In group 2, the PI values were 2.31 +/- 0.55 and 2.37 +/- 0.69 (P = .68) and the RI values were 0.85 +/- 0.07 and 0.86 +/- 0.07 (P = .44) before and after IUD insertion. Finally, we used the mean blood flow indices of the uterine arteries of all patients to compare the effect of IUD insertion. Results were also not statistically significant when we compared PI and RI before and after IUD insertion. The presence of an IUD does not interfere with the vascular resistance of the uterine arteries that can be shown by Doppler flow assessments 1 month after insertion.

  12. ACT NOW: Kindergarten children, eco citizens at its best - Pilot project in Algeria : Green Buds (Eco Bourgeons); AGIR MAINTENANT : Les enfants de la maternelle, eco citoyens par excellence -- Projet pilote en Algerie : Eco Bourgeons

    Energy Technology Data Exchange (ETDEWEB)

    Zahid, Fatima Djalila; Stambouli, Amine Boudghene; Youcef, Reda Dali

    2010-09-15

    Based on originality, reproducibility, impact, duration and consistence of action, the Green Buds pilot program (Eco Bourgeons) in Algeria under the wings of the 'El Baraim' association has for slogan: 'Consume adequately, live better' ('Consommons juste, vivons mieux'). The long term objective: Introduce the ED as a subject in the national education program. [French] Inculquer des eco gestes a 672 enfants de la maternelle dans le sens de la ME a travers un programme educatif riche et adequat, c'est eduquer nos futurs citoyens (industriels, dirigeants, etc.) au respect de nos ressources energetiques et de l'environnement. Se basant sur les criteres de l'originalite, la reproductibilite, l'impact, la duree et la ''consistance'' de l'action, le projet 'Eco Bourgeons' pilote en Algerie sous tutelle de l'association 'El Baraim' a pour slogan : 'Consommons juste, vivons mieux'. L'objectif a long terme: Introduire la ME comme matiere dans le Programme de l'Education Nationale.

  13. Revisiting eco-ethics and econ-ethics

    Directory of Open Access Journals (Sweden)

    Otto Kinne

    2002-11-01

    Full Text Available Modern humanity can survive only if traditional ethics are extended to include eco-ethics and econ-ethics. Success or failure in developing and implementing these new ethical constructs will affect the fate of our species Homo sapiens and that of millions of other forms of life. In the long run failure to accept and apply eco-ethics and econ-ethics would reduce the capacities of Planet Earth to support life.

  14. Dinamismo conceptual en las bases de conocimiento terminológico: el caso de EcoLexicon

    Directory of Open Access Journals (Sweden)

    Pamela Faber Benítez

    2010-05-01

    Full Text Available Introducción: la nueva orientación de la Terminología, en sentido lingüístico-conceptual, ha dado lugar al desarrollo de un nuevo enfoque centrado en el discurso y el uso real de los términos (Temmerman y Kerremans, 2003. Este cambio de paradigma ha originado una mejora sustancial del contenido de las bases de conocimiento terminológico. Sin embargo, la novedad más destacada en cuanto a la modelización del conocimiento parte del uso extensivo de las ontologías, añadiéndole un mayor grado de expresividad semántica a la Terminología. Objetivo: presentar la base de conocimiento EcoLexicon, desarrollada en la Universidad de Granada por el grupo de investigación LexiCon. Para sacar el máximo partido de las ventajas que ofrece la aplicación de ontologías se propone la definición de un inventario de relaciones conceptuales junto con su potencial combinatorio. A su vez, éste origina una representación restringida por el contexto. Método: según los datos extraídos del corpus recopilado para la investigación, los conceptos del dominio se dividen según su tipología y su poder relacional. Se aplican características propias del lenguaje de ontologías (Web Ontology Language (OWL para realizar inferencias (ej. la transitividad de la meronimia. Resultados: la definición de las relaciones conceptuales según la naturaleza de los conceptos ofrece una solución cuantitativa para la sobrecarga de información y, a su vez, cualitativa, para la adquisición del conocimiento. Conclusiones: EcoLexicon une con éxito la Terminología y la capacidad expresiva de las ontologías, lo que ayudará en el futuro a diseñar sistemas de búsqueda adaptados a distintos usuarios.

  15. Microwave-assisted enhancement of milkweed (Calotropis procera L.) leaves as an eco-friendly source of natural colorants for textile.

    Science.gov (United States)

    Hussaan, Muhammad; Iqbal, Naeem; Adeel, Shahid; Azeem, Muhammad; Tariq Javed, M; Raza, Ali

    2017-02-01

    Application of natural colorants to textile fabrics has gained worldwide public acceptance due to the hazardous nature of synthetic dyes. Present study investigated the microwave's mediated extraction of natural colorants from leaves of milkweed (Calotropis procera L.) as well as their application to cotton fabrics assisted with biochemical mordants. Dye extraction from C. procera leaves was carried out in various mediums (alkali and aqueous), and the extracted dye as well as cotton fabrics was irradiated with microwaves for 2, 4, 6, 8, or 10 min. Effect of various temperature regimes and sodium chloride (NaCl) concentrations was also evaluated on the color strength of dyed cotton fabrics. The results revealed that extraction of natural colorants was enhanced when microwave radiations were applied for 4 min by using alkali as an extraction medium as compared to aqueous one. Optimum dyeing of cotton fabrics was achieved by using NaCl at a temperature of 55 °C. Among the chemical mordants, iron was effective for better color strength when used as pre- and post-mordant. Among the studied bio-mordants, extract of Acacia nilotica bark significantly improved the color strength and fastness properties as pre-mordant and Curcuma longa tuber as post-mordant. It was concluded that extract of C. procera leaves was a potential source of natural colorants and a high level of dye was obtained upon irradiation of alkali-solubilized extract for 4 min. Application of NaCl at concentration of 3 g/100 mL and temperature treatment of 55 °C significantly improved the color strength of dyed cotton fabrics.

  16. Necrotizing fasciitis of soft tissues. Diagnostic imaging findings and literature review; Le fascite necrotizzante dei tessuti molli. Ruolo della diagnostica per immagini e revisione della letteratura

    Energy Technology Data Exchange (ETDEWEB)

    Parenti, G.C.; Marri, C. [Ospedale Civile S. Maria delle Croci, Ravenna (Italy). Servizio di Radiodiagnostica; Calandra, G. [Ospedale Civile S. Maria delle Croci, Ravenna (Italy). Unita' operativa di Pronto Soccorso; Morisi, C. [Ospedale Civile S. Maria delle Croci, Ravenna (Italy). Servizio di Anatomia Patologica; Zabberoni, W. [Ospedale Civile S. Maria delle Croci, Ravenna (Italy). Div. di Malattie Infettive, Gruppo di rilevamento dati sulle INPS-ASL

    2000-05-01

    maggio 1991 a febbraio 1998 sono giunti alla nostra osservazione 130 casi di infezioni necrotizzanti progressive dei tessuti molli; in 32 casi l'eta' era compresa fra 22 e 84 anni; la diagnosi istologica retrospettiva e' risultata quella della fascite necrotizzante. Le sedi interessate dal processo sono state: arti (26/32), regioni cervicale (5/32) e perineale (1/32). Diciannove pazienti (19/32) sono stati sottoposti d'urgenza a esame radiografico eseguito anche per lo studio dei tessuti molli. L'esame ecografico e' stato eseguito d'urgenza in tutti i 32 pazienti. La valutazione dei pazienti con sospetto di infezioni necrosanti progressive e' affidata di solito a un gruppo di operatori esperti in diagnostica ecografica dei tessuti molli perischeletrici. L'esame TC e' stato eseguito in 9 casi (9/32); a ognuno di questi pazienti e' stato somministrato mdc iodato per via endovenosa. Con gli esami ecografico ed eco color Doppler, nel sospetto di fascite necrotizzante, e' possibile offrire indicazioni utili e affidabili per il corretto e rapido orientamento diagnostico; in particolare tale metodica e' in grado di rilevare precocemente alterazioni al tessuto adiposo sottocutaneo (28/32), alla fascia (18/32) e al tessuto molecolare (15/32). E' stata riscontrata buona correlazione tra alterazione tissutale rilevata con l'esame ecografico e reperto istologico; l'ecografia non ha evidenziato alterazioni al tessuto adiposo sottocutaneo (3/32) e al tessuto molecolare (8/32) in 11 casi pur evidenti all'esame istologico. La TC con mdc puo' essere utile per la migliore definizione dell'estensione della malattia e per la dimostrazione di eventuali complicanze, soprattutto in sedi difficili da raggiungere con l'ecografia. Le probabilita' di guarigione per i pazienti affetti da fascite necrotizzante sono direttamente proporzionali alla precocita' della diagnosi e all

  17. Organic Foods: Do Eco-Friendly Attitudes Predict Eco-Friendly Behaviors?

    Science.gov (United States)

    Dahm, Molly J.; Samonte, Aurelia V.; Shows, Amy R.

    2009-01-01

    Objective: The purpose of this study was to determine whether student awareness and attitudes about organic foods would predict their behaviors with regard to organic food consumption and other healthy lifestyle practices. A secondary purpose was to determine whether attitudes about similar eco-friendly practices would result in socially conscious…

  18. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  19. The EcoCyc database: reflecting new knowledge about Escherichia coli K-12.

    Science.gov (United States)

    Keseler, Ingrid M; Mackie, Amanda; Santos-Zavaleta, Alberto; Billington, Richard; Bonavides-Martínez, César; Caspi, Ron; Fulcher, Carol; Gama-Castro, Socorro; Kothari, Anamika; Krummenacker, Markus; Latendresse, Mario; Muñiz-Rascado, Luis; Ong, Quang; Paley, Suzanne; Peralta-Gil, Martin; Subhraveti, Pallavi; Velázquez-Ramírez, David A; Weaver, Daniel; Collado-Vides, Julio; Paulsen, Ian; Karp, Peter D

    2017-01-04

    EcoCyc (EcoCyc.org) is a freely accessible, comprehensive database that collects and summarizes experimental data for Escherichia coli K-12, the best-studied bacterial model organism. New experimental discoveries about gene products, their function and regulation, new metabolic pathways, enzymes and cofactors are regularly added to EcoCyc. New SmartTable tools allow users to browse collections of related EcoCyc content. SmartTables can also serve as repositories for user- or curator-generated lists. EcoCyc now supports running and modifying E. coli metabolic models directly on the EcoCyc website. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  20. Vegetarian Eco-feminist Consciousness in Carol Ann Duffy’s Poetry

    Directory of Open Access Journals (Sweden)

    Jie Zhou

    2015-07-01

    Full Text Available This paper discusses vegetarian eco-feminist consciousness in Carol Ann Duffy’s poetry by close analysis of two poems, namely “The Dolphins” and “A Healthy Diet” from her poem collection Standing Female Nude. The former is a dramatic monologue of a dolphin, which is exploited by people, and the latter is a dramatic monologue of an omnipotent observer in a restaurant. Both poems criticized the species-ism, and together, they showed the poet’s vegetarian eco-feminist consciousness. A close reading of the two poems from the eco-feminist perspective helps the reader understand why Carol Ann Duffy is honored as the first woman poet laureate in British history, and better understand vegetarian eco-feminism and its influence in British society. Keywords: eco-feminism; consciousness, species-ism, vegetarian, animal, diet

  1. Assessment of eco-environmental quality of Western Taiwan Straits Economic Zone.

    Science.gov (United States)

    Ma, He; Shi, Longyu

    2016-05-01

    Regional eco-environmental quality is the key and foundation to the sustainable socio-economic development of a region. Eco-environmental quality assessment can reveal the capacity of sustainable socio-economic development in a region and the degree of coordination between social production and the living environment. As part of a new development strategy for Fujian Province, the Western Taiwan Straits Economic Zone (hereafter referred to as the Economic Zone) provides an important guarantee for the development of China's southeastern coastal area. Based on ecological and remote sensing data on the Economic Zone obtained in 2000, 2005, and 2010, this study investigated county-level administrative regions with a comprehensive index of eco-environmental indicators. An objective weighting method was used to determine the importance of each indicator. This led to the development of an indicator system to assess the eco-environmental quality of the economic zone. ArcGIS software was used to assess the eco-environmental quality of the economic zone based on each indicator. The eco-environmental quality index (EQI) of the county-level administrative regions was calculated. The overall eco-environmental quality of the Economic Zone during the period studied is described and analyzed. The results show that the overall eco-environmental quality of the Economic Zone is satisfactory, but significant intraregional differences still exist. The key to improving the overall eco-environmental quality of this area is to restore vegetation and preserve biodiversity.

  2. Field testing of eco-speed control using V2I communication.

    Science.gov (United States)

    2016-04-15

    This research focused on the development of an Eco-Cooperative Adaptive Cruise Control (EcoCACC) : System and addressed the implementation issues associated with applying it in the field. : The Eco-CACC system computes and recommends a fuel-efficient...

  3. Eco-Innovation Manual

    DEFF Research Database (Denmark)

    O'Hare, Jamie Alexander; McAloone, Tim C.; Pigosso, Daniela Cristina Antelmi

    This tool is designed to support you in identifying companies that are more likely to be willing and able to benefit from eco-innovation services. The tool provides questions to guide your research analysis, starting at the industry sector level, before progressing through the market level, down ...

  4. The Eco House

    Energy Technology Data Exchange (ETDEWEB)

    Hobbett, A. (Leicester Ecology Trust (United Kingdom))

    The Eco House is a former park keeper's lodge on the periphery of Leicester's largest public park. Taken over by Leicester Ecology Trust in 1990, the Eco House was a successor to the Trust's earlier low energy house. This has been a local authority decant house, retrofitted to show the potential for increased energy efficiency in older buildings. Many of the ideas from the earlier project were adopted by the new with a widening of its remit to include all matters of environmental concern connected with people's homes. So in addition to energy efficiency, other issues addressed include conservation of resources, wildlife, organic gardening, food production, water, environmental consumerism, recycling and health. Given that the use of energy is regarded by many environmentalists to be the single most important environmental issue today, and one which is easiest for households to address, it remains the project's dominant theme. (author)

  5. Evaluation of pelvic varicose veins using color Doppler ultrasound: comparison of results obtained with ultrasound of the lower limbs, transvaginal ultrasound, and phlebography Avaliação de varizes pélvicas por Doppler colorido: comparação dos resultados obtidos com ultrassom dos membros inferiores, ultrassom transvaginal e flebografia

    Directory of Open Access Journals (Sweden)

    Fanilda Souto Barros

    2010-06-01

    Full Text Available Introduction: Pelvic varicose veins, one of the main causes of chronic pelvic pain and dyspareunia, are an important source of reflux for lower limb varicose veins, especially in recurrent cases. Color Doppler ultrasound of the lower limbs and transvaginal ultrasound are the noninvasive diagnostic methods most commonly used to assess pelvic venous insufficiency, whereas phlebography is still considered as the gold standard. Objectives: To determine the prevalence of lower limb varicose veins originating from the pelvis in a group of female patients and to determine the agreement between results obtained via color Doppler ultrasound of the lower limbs, transvaginal ultrasound, and phlebography. Methods: The sample comprised female patients referred to a vascular laboratory for lower limb screening. Patients diagnosed with deep venous thrombosis were excluded. Data analysis included kappa coefficient of agreement, McNemar's test, sensitivity and specificity values. Results: Of a total of 1,020 patients, 124 (12.2% had findings compatible with reflux of pelvic origin. Among these patients, 51 (41.2% were recurrent cases. A total of 249 were submitted to transvaginal ultrasound. There was significant agreement between lower limb ultrasonographic findings and transvaginal findings. Phlebography was performed in 54 patients. The comparison between transvaginal ultrasound and phlebography was associated with a 96.2% sensitivity and 100% specificity. Conclusions: The authors draw attention to the relatively high prevalence of lower limb varicose veins originating from the pelvis, suggesting an important but underdiagnosed cause of recurrent varicose veins.Introdução: AS VARIZES Pélvicas, uma das principais causas de dor pélvica crônica e dispareunia, são uma importante fonte de refluxo para as varizes dos membros inferiores, especialmente em casos recorrentes. O Doppler colorido dos membros inferiores e o ultrassom transvaginal são os m

  6. Eco-Innovation for Sustainability: Evidence from 49 Countries in Asia and Europe

    Directory of Open Access Journals (Sweden)

    Jang-Hwan Jo

    2015-12-01

    Full Text Available Following the trend on focusing on a nation’s economic-growth, side effects such as resource exhaustion, environmental pollution, and social injustice have begun to appear. As a solution, eco-innovation has received a great amount of attention from European countries and as a result, many efforts to analyze the development of eco-innovation quantitatively have been made. This study aims to evaluate the validity of an eco-innovation index developed to support the sustainable development goal. For this purpose, four factors of eco-innovation—capacity, supportive environment, activity, and performance—were applied to three categories of the Triple-Bottom-Line (TBL concept in sustainability to compare the eco-innovation development level of 49 Asia-Europe Meeting countries. Factors for eco-innovation and TBL at the country level were organized in quartile and compared to see strength and weaknesses for each nation. In order to test if eco-innovation factors of a nation adequately reflect its sustainability, we used various comparisons of ANOVA. The results of this study are as follows: First, the one-way ANOVA tests present the scores for capacity, supportive environment, and performance as grouped into four quartiles in the same pattern as their economic, social, and environmental scores. The three-way ANOVA tests showed significance for the economic category. Scores for capacity, supportive environment, activity and performance were significant at a nation’s economic level. Lastly, the MANOVA test revealed that TBL significantly explains four eco-innovation factors. In addition, the eco-innovation performance level of European nations and Asian nations were compared. The possibility that many nations still have room to be competitive in their eco-innovation efforts was identified. Nations with unbalanced eco-innovation growth are urged to implement new strategies to balance their growth. Therefore, this research contributes to extending

  7. The Application Potential of Eco-Efficiency for Greening Company

    Science.gov (United States)

    Prasaja, Lukman Eka; Hadiyanto

    2018-02-01

    Eco-Efficiency emerged in the 1990s as a measure of "the efficiency that ecological sources use to meet human needs." As a tool in economic and environmental integration, Eco-efficiency needs to be promoted further so that regulation in government and industrial management can include it as an important instrument. This paper provides several approaches that can help various industries to develop effective eco-efficiency principles. The approach used is to maximize the role of the Steering Committee of the company's internal environment. Utilization of natural resources such as water, forests, mines and energy needs need to be balanced with Eco-Efficiency so that natural exploitation can be well controlled so that sustainable development aspired by the world can be realized.

  8. Eco-labelling of shampoos, shower gels and foam baths.

    Science.gov (United States)

    Klaschka, Ursula; Liebig, Markus; Knacker, Thomas

    2007-01-01

    Environmental issues of personal care products have been met with little attention in the past. Monitoring data as well as preliminary environmental risk assessments indicate that some ingredients in personal care products might be relevant pollutants in the environment. Following the precautionary principle, eco-labelling is proposed as an effective tool for source control of one major group of personal care products, shampoos, shower gels and foam baths (SSBs). Eco-labelling is a soft, but effective market driven and product specific approach to lower discharge of environmentally detrimental substances. Products that fulfil the criteria proposed help to minimise the impact of SSBs on the environment. Available assessment tools for dangerous substances (e.g. current legislation on environmental risk assessments and classification, and labelling, eco-labelling criteria for similar products, the calculation of the critical dilution volume) were adapted and integrated into the criteria for the eco-labelling of SSBs. A short outline of the eco-labelling criteria developed for SSBs is provided. The basic criteria concern the effects of the substances discharged into the waste water during and after use. Products with an eco-label award may exclusively contain substances for which basic information about their effects on the environment is available. They may not contain persistent, bioaccumulating, toxic or ecotoxicological substances. In addition, the basic criteria include requirements for the container and consumer information. The basic criteria for eco-labelling SSBs are based on the actual state of science and are at the same time as simple and transparent as possible to ensure the best applicability. SSBs that comply with the described basic criteria can contribute to a lower chemical burden of waste water treatment plants and surface water. The proposal for basic criteria described should stimulate discussion on eco-labelling of SSBs. It should help to pass

  9. SOFT: smooth OPC fixing technique for ECO process

    Science.gov (United States)

    Zhang, Hongbo; Shi, Zheng

    2007-03-01

    SOFT (Smooth OPC Fixing Technique) is a new OPC flow developed from the basic OPC framework. It provides a new method to reduce the computation cost and complexities of ECO-OPC (Engineering Change Order - Optical Proximity Correction). In this paper, we introduce polygon comparison to extract the necessary but possibly lost fragmentation and offset information of previous post-OPC layout. By reusing these data, we can start the modification on each segment from a more accurate initial offset. In addition, the fragmentation method in the boundary of the patch in the previous OPC process is therefore available for engineers to stitch the regional ECO-OPC result back to the whole post-OPC layout seamlessly. For the ripple effect in the OPC, by comparing each segment's movement in each loop, we much free the fixing speed from the limitation of patch size. We handle layout remodification, especially in three basic kinds of ECO-OPC processes, while maintaining other design closure. Our experimental results show that, by utilizing the previous post-OPC layout, full-chip ECO-OPC can realize an over 5X acceleration and the regional ECO-OPC result can also be stitched back into the whole layout seamlessly with the ripple effect of the lithography interaction.

  10. O fundamento estrutural do pensamento de Umberto Eco

    Directory of Open Access Journals (Sweden)

    Winfried Nöth

    2016-08-01

    Full Text Available Uma análise detalhada apresenta o método argumentativo a contrario, característico do artigo "Existe a contracultura?", de Umberto Eco, como paradigmático do princípio estruturalista da constituição do sentido por meio de oposições semânticas. O artigo argumenta que muitos dos escritos de Eco podem ser lidos como aplicações do princípio estruturalista de que apenas diferenças ou oposições carregam significação. A evidência do modo como o pensamento de Eco está sob o encanto do princípio das oposições e da dialética da presença e da ausência é apresentada através do levantamento dos escritos gerais de Eco e também da inspeção das obras A estrutura ausente e Semiótica e filosofia da linguagem. Além disso, o artigo revela que o pensamento de Eco é igualmente atraído tanto por processos nos quais oposições anulam ou dissolvem a si próprias quanto pela crítica pós-estruturalista do pensamento estruturalista.

  11. Green Eco-Driving Effects in Non-Congested Cities

    Directory of Open Access Journals (Sweden)

    Juan Francisco Coloma

    2017-12-01

    Full Text Available Despite technological advances in engines and fuels, the transportation sector is still one of the largest emitters of greenhouse gas (GHG. Driving patterns, including eco-driving techniques, are a complementary measure for saving GHG emissions. Most eco-driving studies so far have been conducted in large cities suffering chronic congestion problems. The aim of this research is therefore to analyse the potential of driver behaviour for reducing emissions in a small non-congested city. Driver performance parameters such as travel speeds, number of stops, revolutions per minute, and maximum acceleration-deceleration are also studied. The methodology is designed to measure the effect of both eco-driving and eco-routing under real traffic conditions. A campaign was carried out in the city of Caceres (Spain to collect data on various types of roads under different traffic conditions. This research concludes that eco-driving leads to CO2 savings on all routes and road types of 17% in gasoline engines and 21% in diesel, although travel times are increased by 7.5% on average. The shortest route is also the most ecological, regardless of the traffic volume and characteristics, implying that consumption in non-congested cities depends mainly on distance travelled rather than driving patterns in terms of number of stops, speed and acceleration.

  12. Correlation between US and MRI for prenatal lung volumetry in diaphragmatic hernia, and use of Doppler to identify the ipsilateral lung cap

    Energy Technology Data Exchange (ETDEWEB)

    Castellote, Amparo; Mencho, Sandra; Cadavid, Lina; Piqueras, Joaquim; Enriquez, Goya [University Children' s Hospital Vall d' Hebron, Department of Pediatric Radiology, Barcelona (Spain); Carreras, Elena; Higueras, Teresa [University Hospital Vall d' Hebron, Department of Obstetrics and Gynecology, Barcelona (Spain)

    2011-12-15

    Pulmonary hypoplasia is a common cause of neonatal death. To describe the correlation between relative fetal lung volume (RFLV) and lung-to-head ratio (LHR) in fetuses with unilateral diaphragmatic hernia. Additionally, to describe identification of the ipsilateral lung cap by power Doppler. Single-institution study of consecutive fetuses with diaphragmatic hernia. LHR (by US) and RFLV (by MRI) were correlated in fetuses with and without an ipsilateral lung cap seen at MRI. In four, color/power Doppler was used to follow the pulmonary artery of the ipsilateral lung to identify the compressed cap. The study included 48 fetuses of 20-38 weeks' gestational age (mean, 26 weeks). Mean LHR was 1.52 (range, 0.6-3) in fetuses with a lung cap and 1.15 (range, 0.6-2.58) in fetuses without (P = 0.043). Mean RFLV was 47.4% (range, 18-80%) in fetuses with and 32.9% (range, 14-57%) in fetuses without a lung cap (P = 0.005). RFLV and LHR correlated (r = 0.41, P = 0.01 in those with a cap; r = 0.50, P = 0.05 in those without). Power Doppler identified the ipsilateral lung cap and pulsed Doppler confirmed pulmonary vascularization in four of four fetuses. LHR underestimates lung volume in fetuses with an ipsilateral lung cap. Power Doppler may be useful for identifying the cap. (orig.)

  13. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  14. First Image Products from EcoSAR - Osa Peninsula, Costa Rica

    Science.gov (United States)

    Osmanoglu, Batuhan; Lee, SeungKuk; Rincon, Rafael; Fatuyinbo, Lola; Bollian, Tobias; Ranson, Jon

    2016-01-01

    Designed especially for forest ecosystem studies, EcoSAR employs state-of-the-art digital beamforming technology to generate wide-swath, high-resolution imagery. EcoSARs dual antenna single-pass imaging capability eliminates temporal decorrelation from polarimetric and interferometric analysis, increasing the signal strength and simplifying models used to invert forest structure parameters. Antennae are physically separated by 25 meters providing single pass interferometry. In this mode the radar is most sensitive to topography. With 32 active transmit and receive channels, EcoSARs digital beamforming is an order of magnitude more versatile than the digital beamforming employed on the upcoming NISAR mission. EcoSARs long wavelength (P-band, 435 MHz, 69 cm) measurements can be used to simulate data products for ESAs future BIOMASS mission, allowing scientists to develop algorithms before the launch of the satellite. EcoSAR can also be deployed to collect much needed data where BIOMASS satellite wont be allowed to collect data (North America, Europe and Arctic), filling in the gaps to keep a watchful eye on the global carbon cycle. EcoSAR can play a vital role in monitoring, reporting and verification schemes of internationals programs such as UN-REDD (United Nations Reducing Emissions from Deforestation and Degradation) benefiting global society. EcoSAR was developed and flown with support from NASA Earth Sciences Technology Offices Instrument Incubator Program.

  15. Looking for a Framework for Analyzing Eco-innovation Dynamics

    DEFF Research Database (Denmark)

    Yang, Yan

    2011-01-01

    Looking for a Framework for Analyzing Eco-innovation Dynamics: A Triple Helix Model of Innovation Perspective.......Looking for a Framework for Analyzing Eco-innovation Dynamics: A Triple Helix Model of Innovation Perspective....

  16. Preparation, characterization and antibacterial effects of eco-friendly ...

    African Journals Online (AJOL)

    Purpose: To synthesize and characterize eco-friendly gold nanorods (Au-NRs) and to assess their effects against two bacterial strains. Methods: Synthesis of eco-friendly gold nanorods was done from an aqueous solution of chloroauric acid and cetyltrimethylammonium bromide by mixing Olea europaea fruit and Acacia ...

  17. Eco-Innovation in the Value Chain

    DEFF Research Database (Denmark)

    McAloone, Tim C.; Mougaard, Krestine; Restrepo-Giraldo, John Dairo

    2010-01-01

    processes is often reactive, resulting in a retrospective and insufficient approach. This paper describes the mechanisms, opportunities and barriers for the actual realisation of value chain based eco-innovation, together with a first indication of a methodical approach to realising eco-innovation.......It is well known that companies face challenges integrating environmental considerations into their product development processes and there is an established body of research focusing on ways and means to aid this. The approach for integrating environmental considerations into product development...

  18. Evaluación sensorial de láminas de mango (Manguifera indica L. cv. Keitt fortificadas con cloruro de calcio mediante deshidratación osmótica con pulsos de vacío

    Directory of Open Access Journals (Sweden)

    Richard Alejandro Gómez

    2013-12-01

    Full Text Available Se evaluó el efecto de la fortificación con cloruro de calcio (CaCl2 de láminas de mango por medio de la deshidratación osmótica con pulsos de vacío, sobre los atributos sensoriales color, sabor y textura (dureza. Se utilizaron frutos de mango del cultivar Keitt cosechados en estado de madurez fisiológica a partir de los cuales se obtuvieron láminas de 4 x 4 x 0,5 cm. Las láminas de mango se sometieron a 4 tratamientos osmóticos que incluían distintas soluciones con concentraciones de CaCl2 (0; 0,5; 1,5 y 2,5 %, durante 24 horas, aplicando pulsos de vacío. La preferencia de las láminas de mango fortificadas se determinó utilizando una escala hedónica de 9 puntos (desde 9: ‘gusta extremadamente’, pasando por 5: ‘ni gusta ni disgusta’, hasta 1: ‘disgusta extremadamente’. En la prueba participó un panel de 100 consumidores no entrenados, de ambos sexos y con edades entre 18 y 50 años. A cada panelista se les entregó simultáneamente 4 muestras codificadas con números aleatorios de tres dígitos y se les pidió que probaran y calificaran los atributos color, sabor y textura (dureza, según su apreciación y de acuerdo a la escala. Para el análisis de los datos se utilizó el análisis no paramétrico de Kruskal-Wallis. Las diferencias entre los tratamientos se determinaron mediante una prueba de rangos. Se aplicó un análisis de correlación entre las variables sensoriales a través de la prueba de rangos de Spearman. El panel detectó que el color de las láminas sometidas al tratamiento con 2,5 % CaCl2 varió significativamente (p ≤ 0,01 con relación a los demás. Un aumento de la concentración de CaCl2 hizo más amargas y duras las láminas de mango. Hubo correlación altamente positiva entre la preferencia del sabor y la dureza y con el color de las muestras. Las láminas con 0 % CaCl2 fueron las más aceptadas a nivel sensorial, pero para la fortificación con calcio las de mayor aceptabilidad fueron las

  19. Envasado de Carne de Vacuno con Hueso y Grasa en Atmósfera Modificada con CO2 y CO Packaging of Bone and Fat Containing Beef Meat under a Modified Atmosphere Containing CO2 and CO

    OpenAIRE

    Estrella R Aspé; Marlene D Roeckel; Cristina Martí; Romel Jiménez

    2008-01-01

    Se evaluó el efecto de envasado en atmósfera modificada (MAP) con bajo contenido de CO (0.1% y 0.4%) y presencia de CO2 sobre el color rojo y la vida útil de carne de vacuno. Se determinaron características microbiológicas, fisicoquímicas, organolépticas-sensoriales y de color del músculo y se compararon los resultados con el MAP de 70%O2+30%CO2. La vida útil de las muestras con O2 fue de 30 días mientras que para las muestras en MAP la vida útil fue de 40 a 45 días y no dependió de la concen...

  20. Smart and eco cities in China and India

    NARCIS (Netherlands)

    Höffken, J.I.; Kneitz, A.

    2016-01-01

    The development of smart and eco cities in both China and in India has gained high political attention and momentum on the national policy agendas. Since 2014, China is officially building an “Ecological Civilization” for which eco-cities are believed to be strong pillars. India has announced a

  1. Using ordinal logistic regression to evaluate the performance of laser-Doppler predictions of burn-healing time

    Directory of Open Access Journals (Sweden)

    Pape Sarah A

    2009-02-01

    Full Text Available Abstract Background Laser-Doppler imaging (LDI of cutaneous blood flow is beginning to be used by burn surgeons to predict the healing time of burn wounds; predicted healing time is used to determine wound treatment as either dressings or surgery. In this paper, we do a statistical analysis of the performance of the technique. Methods We used data from a study carried out by five burn centers: LDI was done once between days 2 to 5 post burn, and healing was assessed at both 14 days and 21 days post burn. Random-effects ordinal logistic regression and other models such as the continuation ratio model were used to model healing-time as a function of the LDI data, and of demographic and wound history variables. Statistical methods were also used to study the false-color palette, which enables the laser-Doppler imager to be used by clinicians as a decision-support tool. Results Overall performance is that diagnoses are over 90% correct. Related questions addressed were what was the best blood flow summary statistic and whether, given the blood flow measurements, demographic and observational variables had any additional predictive power (age, sex, race, % total body surface area burned (%TBSA, site and cause of burn, day of LDI scan, burn center. It was found that mean laser-Doppler flux over a wound area was the best statistic, and that, given the same mean flux, women recover slightly more slowly than men. Further, the likely degradation in predictive performance on moving to a patient group with larger %TBSA than those in the data sample was studied, and shown to be small. Conclusion Modeling healing time is a complex statistical problem, with random effects due to multiple burn areas per individual, and censoring caused by patients missing hospital visits and undergoing surgery. This analysis applies state-of-the art statistical methods such as the bootstrap and permutation tests to a medical problem of topical interest. New medical findings are

  2. Hipotiroidismo, miocardiopatía dilatada y síndrome nefrótico durante el embarazo

    Directory of Open Access Journals (Sweden)

    Ariel K. Saad

    2011-02-01

    Full Text Available El hipotiroidismo en el embarazo es infrecuente, pero cuando ocurre suele asociarse con complicaciones maternas y fetales. Se presenta el caso de una mujer joven sin antecedentes de enfermedad cardiovascular que consulta por ortopnea, dolor torácico y edema de miembros inferiores. Los exámenes pusieron en evidencia la existencia de insuficiencia cardíaca, hipotiroidismo, síndrome nefrótico e insuficiencia renal. El eco-Doppler mostró dilatación de las cuatro cavidades cardíacas con deterioro grave de la función sistólica. El tratamiento con levotiroxina por vía intravenosa mejoró el cuadro clínico y los parámetros de laboratorio. Se analizan los efectos de la hormona tiroidea sobre el aparato cardiovascular y se comentan los mecanismos fisiopatológicos de la insuficiencia cardíaca en el embarazo.

  3. Adapting adaptation: the English eco-town initiative as governance process

    Directory of Open Access Journals (Sweden)

    Daniel Tomozeiu

    2014-06-01

    Full Text Available Climate change adaptation and mitigation have become key policy drivers in the UK under its Climate Change Act of 2008. At the same time, urbanization has been high on the agenda, given the pressing need for substantial additional housing, particularly in southeast England. These twin policy objectives were brought together in the UK government's 'eco-town' initiative for England launched in 2007, which has since resulted in four eco-town projects currently under development. We critically analyze the eco-town initiative's policy evolution and early planning phase from a multilevel governance perspective by focusing on the following two interrelated aspects: (1 the evolving governance structures and resulting dynamics arising from the development of the eco-town initiative at UK governmental level, and the subsequent partial devolution to local stakeholders, including local authorities and nongovernmental actors, under the new 'localism' agenda; and (2 the effect of these governance dynamics on the conceptual and practical approach to adaptation through the emerging eco-town projects. As such, we problematize the impact of multilevel governance relations, and competing governance strategies and leadership, on shaping eco-town and related adaptation strategies and practice.

  4. Eco-efficiency Analysis of Furniture Product Using Life Cycle Assessment

    Directory of Open Access Journals (Sweden)

    Ika Rinawati Dyah

    2018-01-01

    Full Text Available Furniture is one of Indonesia’s main commodities strategically role in economic growth and employment in Indonesia. In their production process there many wastes resulted, such as such as sawdust, cuttings - pieces of wood, components that do not conform to specifications and the edges of wood from a log. Contrast with requirement of timber for furniture industries, availability of raw material sources decrease because of limited forest areas. Beside that, using electricity and chemical material in furniture production process have impact to environment. This study aim to assess the eco-cost and eco-efficiency ratio of the product so strategic recommendations to improve the eco-efficiency of products can be designed. The results of data processing showed the environmental costs of the furniture production process amount Rp 30.887.84. Eco-efficiency index of furniture products studied was 4,79 with the eco-efficiency ratio of 79,12%. This result means that the measured furniture products already profitable and sustainable, as well as its production process is already fairly efficient. However, improved performance of the production process can still be done to improve the eco-efficiency by minimizing the use of raw materials.

  5. Eco-efficiency Analysis of Furniture Product Using Life Cycle Assessment

    Science.gov (United States)

    Rinawati, Dyah Ika; Sriyanto; Sari, Diana Puspita; Prayodha, Andana Cantya

    2018-02-01

    Furniture is one of Indonesia's main commodities strategically role in economic growth and employment in Indonesia. In their production process there many wastes resulted, such as such as sawdust, cuttings - pieces of wood, components that do not conform to specifications and the edges of wood from a log. Contrast with requirement of timber for furniture industries, availability of raw material sources decrease because of limited forest areas. Beside that, using electricity and chemical material in furniture production process have impact to environment. This study aim to assess the eco-cost and eco-efficiency ratio of the product so strategic recommendations to improve the eco-efficiency of products can be designed. The results of data processing showed the environmental costs of the furniture production process amount Rp 30.887.84. Eco-efficiency index of furniture products studied was 4,79 with the eco-efficiency ratio of 79,12%. This result means that the measured furniture products already profitable and sustainable, as well as its production process is already fairly efficient. However, improved performance of the production process can still be done to improve the eco-efficiency by minimizing the use of raw materials.

  6. From an eco-fairy tale to an environmentally friendly lifestyle. An eco-friendly reading project by Agnieszka Marzęcka

    Directory of Open Access Journals (Sweden)

    Anna Kapusta

    2012-06-01

    Full Text Available The article is concerning on the eco-critical literary phenomenon on the perspective of new species polish eco-fairy tale. The fabulous tale about ecological style of life (The metaphorical ecology of human biography was ilustrated by the Agnieszka Marzęcka's modernity tune entitled The Victory of King of Cleanness.

  7. Jordanian dentists' knowledge and implementation of eco-friendly dental office strategies.

    Science.gov (United States)

    Al Shatrat, Sabha M; Shuman, Deanne; Darby, Michele L; Jeng, Hueiwang A

    2013-06-01

    To investigate the implementation of eco-friendly dental office strategies by Jordanian dentists. Self-designed questionnaires were provided to 150 dentists working in private dental practices in the city of Amman, the capital of Jordan. Dentists' names and addresses were obtained from the Jordanian Dental Association. Overall, the level of knowledge about eco-friendly dental offices strategies was high for amalgam, radiology, paper waste, infection control and energy and water conservation. In terms of implementation, the majority of Jordanian dentists apply few eco-friendly dental offices strategies. The most frequently identified barriers to implementation of eco-friendly dental offices strategies were cost and lack of incentives from the government. Most Jordanian dental practices are not eco-friendly. A continued focus on the impact of dental practices on the environment is needed through formal and continuing dental education. Results of this study can guide policy development to encourage implementation of eco-friendly strategies. © 2013 FDI World Dental Federation.

  8. The medical Doppler in hand surgery: its scientific basis, applications, and the history of its namesake, Christian Johann Doppler.

    Science.gov (United States)

    Ghori, Ahmer K; Chung, Kevin C

    2007-12-01

    The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.

  9. Theoretical Study of Watershed Eco-Compensation Standards

    Science.gov (United States)

    Yan, Dandan; Fu, Yicheng; Liu, Biu; Sha, Jinxia

    2018-01-01

    Watershed eco-compensation is an effective way to solve conflicts over water allocation and ecological destruction problems in the exploitation of water resources. Despite an increasing interest in the topic, the researches has neglected the effect of water quality and lacked systematic calculation method. In this study we reviewed and analyzed the current literature and proposedatheoretical framework to improve the calculation of co-compensation standard.Considering the perspectives of the river ecosystems, forest ecosystems and wetland ecosystems, the benefit compensation standard was determined by the input-output corresponding relationship. Based on the opportunity costs related to limiting development and water conservation loss, the eco-compensation standard was calculated.In order to eliminate the defects of eco-compensation implementation, the improvement suggestions were proposed for the compensation standard calculation and implementation.

  10. Noncoherent Doppler tracking: first flight results

    Science.gov (United States)

    DeBoy, Christopher C.; Robert Jensen, J.; Asher, Mark S.

    2005-01-01

    Noncoherent Doppler tracking has been devised as a means to achieve highly accurate, two-way Doppler measurements with a simple, transceiver-based communications system. This technique has been flown as an experiment on the Thermosphere, Ionosphere, Mesosphere, Energetics and Dynamics (TIMED) spacecraft, (launched 7 December 2001), as the operational technique for Doppler tracking on CONTOUR, and is baselined on several future deep space missions at JHU/APL. This paper reports on initial results from a series of successful tests of this technique between the TIMED spacecraft and NASA ground stations in the Deep Space Network. It also examines the advantages that noncoherent Doppler tracking and a transceiver-based system may offer to small satellite systems, including reduced cost, mass, and power.

  11. Anomalous Doppler effects in bulk phononic crystal

    International Nuclear Information System (INIS)

    Cai Feiyan; He Zhaojian; Zhang Anqi; Ding Yiqun; Liu Zhengyou

    2010-01-01

    Doppler effects in simple cubic phononic crystal are studied theoretically and numerically. In addition to observing Doppler shifts from a moving source's frequencies inside the gap, we find that Doppler shifts can be multi-order, anisotropic, and the dominant order of shift depends on the band index that the source's frequency is in.

  12. Eco-Visualization: Promoting Environmental Stewardship in the Museum

    Science.gov (United States)

    Holmes, Tiffany

    2007-01-01

    Eco-visualizations are artworks that reinterpret environmental data with custom software to promote stewardship. Eco-visualization technology offers a new way to dynamically picture environmental data and make it meaningful to a museum population. The questions are: How might museums create new projects and programs around place-based information?…

  13. An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

    Science.gov (United States)

    Tabata, Tomotsugu; Cardon, Lisa A.; Armstrong, Guy P.; Fukamach, Kiyotaka; Takagaki, Masami; Ochiai, Yoshie; McCarthy, Patrick M.; Thomas, James D.

    2003-01-01

    BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

  14. Inducción de la brotación in vitro de microplántulas de nogal (Juglans neotropica) tratadas con Thidiazuron (TDZ) y 6-Bencilaminnopurina (BAP)

    OpenAIRE

    Peña Tapia, Denisse Fabiola; Rocano Curillo, Melida Noemi; Salazar, Jazmin M.; Torres, Carlos S.; Universidad de Cuenca; Dirección de Investigación de la Universidad de Cuenca; DIUC

    2014-01-01

    El nogal (Juglans neotropica) es una especie de gran potencial para proyectos de conservación y agro-productivos en la eco-región Andina. No obstante, su baja capacidad germinativa limita su propagación para reforestación. El objetivo de este estudio fue determinar el efecto del tratamiento con Thidiazuron (TDZ) y 6-Bencilaminopurina (BAP) en la inducción in vitro de brotes de J. neotropica. Las microplántulas tratadas con BAP produjeron más brotes que aquellas tratadas con TDZ. Las microplán...

  15. The Effect of Eco-Schools on Children's Environmental Values and Behaviour

    Science.gov (United States)

    Boeve-de Pauw, Jelle; Van Petegem, Peter

    2013-01-01

    The study examines the effectiveness of eco-schools concerning their students' environmental values and environmental behaviour, and includes 1287 children from fifty-nine schools (thirty-eight eco-schools and twenty-one control schools) in Flanders. Controlling for effects of gender and socio-economic status, analyses show that eco-schools have…

  16. Eco-design of power transmissions systems

    International Nuclear Information System (INIS)

    Wang, W.

    2011-01-01

    The demand to preserve the environment and form a sustainable development is greatly increasing in the recent decades all over the world, and this environmental concern is also merged in electrical power industry, resulting in many eco-design approaches in Transmission and Distribution (T and D) industries. As a method of eco-design, Life Cycle Assessment (LCA) is a systematic tool that enables the assessment of the environmental impacts of a product or service throughout its entire life cycle, i.e. raw material production, manufacture, distribution, use and disposal including all intervening transportation steps necessary or caused by the product's existence. In T and D industries, LCA has been done for a lot of products individually, in order to see one product's environmental impacts and to seek for ways of improving its environmental performance. This eco-design for product approach is a rather well-developed trend, however, as only a single electrical product cannot provide the electrical power to users, electrical system consists of a huge number of components, in order to investigate system's environmental profile, the entire environmental profiles of different composing products has to be integrated systematically, that is to say, a system approach is needed. Under this philosophy, the study 'Eco-design of Power Transmission Systems' is conducted in this thesis, with the purpose of analysing the transmission systems' environmental impacts, locating the major environmental burden sources of transmission systems, selecting and/or developing methodologies of reducing its environmental impacts. (author)

  17. Diagnosis of Pentalogy of Cantrell in the First Trimester Using Transvaginal Sonography and Color Doppler

    Directory of Open Access Journals (Sweden)

    Ayşe Figen Türkçapar

    2015-01-01

    Full Text Available We report the prenatal diagnosis of Cantrell syndrome in the first trimester. During a routine transabdominal ultrasonographic examination, a midline supraumbilical abdominal wall defect including herniated liver and ectopia cordis with a large omphalocele containing the intestines and cystic hygroma was incidentally identified at the 12th week of gestation. A transvaginal sonography examination revealed a severe lumbosacral scoliosis in addition to the inability to visualize the abdominal aorta which was indicative of a severe intracardiac defect. The parents opted for pregnancy to be terminated. In this case report, we discuss the complementary role of transvaginal sonography and Doppler imaging in the diagnosis of Cantrell syndrome in early pregnancy.

  18. FoldEco: A Model for Proteostasis in E. coli

    Directory of Open Access Journals (Sweden)

    Evan T. Powers

    2012-03-01

    Full Text Available To gain insight into the interplay of processes and species that maintain a correctly folded, functional proteome, we have developed a computational model called FoldEco. FoldEco models the cellular proteostasis network of the E. coli cytoplasm, including protein synthesis, degradation, aggregation, chaperone systems, and the folding characteristics of protein clients. We focused on E. coli because much of the needed input information—including mechanisms, rate parameters, and equilibrium coefficients—is available, largely from in vitro experiments; however, FoldEco will shed light on proteostasis in other organisms. FoldEco can generate hypotheses to guide the design of new experiments. Hypothesis generation leads to system-wide questions and shows how to convert these questions to experimentally measurable quantities, such as changes in protein concentrations with chaperone or protease levels, which can then be used to improve our current understanding of proteostasis and refine the model. A web version of FoldEco is available at http://foldeco.scripps.edu.

  19. Consumer Acceptance of Eco-Labeled Fish: A Mexican Case Study

    Directory of Open Access Journals (Sweden)

    Mónica Pérez-Ramírez

    2015-04-01

    Full Text Available Fish eco-labeling is a market-based incentive program for sustainable fisheries. This paper examines consumers’ acceptance of eco-labeled fish by using data from a pilot study conducted in a coastal area of northwestern Mexico. An ordered probit model was applied, using 364 observations. The results show that most respondents favor the idea of eco-labeled fish as a sustainable option and know that this is a costlier option. Income level, consumers’ occupation and frequency of fish consumption are factors taken into account in the buying decision. Price was not a statistically significant factor affecting purchase decision. The study suggests that employed consumers with knowledge of labels may prioritize their demand for eco-labeled fish. Thus, providing a clear definition of sustainability that increases consumer awareness might be a promising strategy in developing the market for eco-labeled fish. The results and their implications could be employed as an element for future development of consumer policies related to fish sustainability.

  20. The innovative application studty on eco-packaging design and materials

    OpenAIRE

    Cui Yong Min; Ren Xin Guang

    2016-01-01

    The paper solves the increasingly deteriorate environmental problems by positively exploring how to utilize and develop eco-packaging design reasonably. The paper explores an effective method that combines eco-packaging and environmental protection materials, hoping to define the sustainable development road of packaging design. The paper is centered on the design application of eco-packaging and environmental protection materials, applies and analyzes the method to obtain innovative design r...

  1. Percepciones del color y de la forma de los empaques: una experiencia de aprendizaje

    Directory of Open Access Journals (Sweden)

    Ana María Arboleda Arango

    2008-01-01

    Full Text Available midores al color y a la forma de los productos se crea a partir de su experiencia con los empaques y con el uso del producto. Este estudio analiza tal premisa de manera exploratoria, utilizando la metodología cualitativa de grupos focales. Así, los resultados sugieren que el hábito y la familiaridad del consumidor predisponen la búsqueda de ciertas características, en cuanto color y forma, que le permiten identificar el producto, sus atributos y su utilidad. Finalmente, dada la generalización que el consumidor hace de los símbolos, se recomienda conservar en los empaques códigos propios de la categoría para garantizar el reconocimiento del producto y evitar confusiones con los de otras categorías. Ante empaques con características diferentes a las de la categoría, se deben diseñar estrategias de comunicación para procurar el aprendizaje de nuevos símbolos.

  2. Estimation of the nopal cactus (Opuntia cochenillifera for color removal in drinking water Evaluación de la tuna (Opuntia cochenillifera para la remoción del color en agua potable

    Directory of Open Access Journals (Sweden)

    Joaquín Jiménez Antillón

    2012-12-01

    Full Text Available The efficiency of nopal cactus to remove color in river and artificial waters for human consumption was evaluated. The performance of nopal was compared with that of aluminum sulfate coagulant and a cationic flocculant.The river water was cha- racterized by high color, low turbidity, alkalinity and hardness, and a high percentage of dissolved oxygen. The cactus leaves showed no activity as unique coa- gulant to be evaluated only in river water. In artificial water, as a sole treatment (45 mg/l, an efficiency of 94% in color removal was observed, slightly higher than that of the conventional treatment (20 mg/l Al2 (SO43 and 2 mg/l of cationic flocculant with a removal of 89%. However, water treated with nopal left a residual COD value doubled (21 mg/l compared to con- ventional treatment. In the treatment of artificial water, nopal as a flocculant showed a color removal of 92% and a residual COD of 31.5 mg /l applied at a dose of 22.5 mg/l and 7 mg/l of Al2 (SO43. The nopal was not very effective to remove the color produced by humic substances in waters of low turbidity and alkalinity, but its applicability as a coagulant/flocculant in waters of high turbidity and alkalinity is promising. It is recommended to extract the active ingredients of natural products to reduce the organic load of treated water and prevent the formation of disin- fection byproducts.El estudio evaluó la eficiencia del cactus de la tuna para remover el color en agua de río y agua artificial para el consumo humano. Se comparó su desem- peño con el coagulante sulfato de aluminio y un floculante catiónico. El agua fluvial se caracterizó por presentar alto color, baja turbidez, alcalinidad y dureza y alto porcentaje de oxígeno disuelto. Las hojas de tuna no mostraron actividad como coagulante único al ser evaluadas en agua de río. Se observó una eficiencia de remoción de color del 94% en agua artificial, cuando se aplicó como tratamiento único (45 mg/l, poco

  3. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    attractive properties. An evaluation based on an existing SEASAT processor is reported. The time-domain algorithms are shown to be extremely efficient with respect to requirements on calculations and memory, and hence they are well suited to real-time systems where the Doppler estimation is based on raw SAR......After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to have...... data. For offline processors where the Doppler estimation is performed on processed data, which removes the problem of partial coverage of bright targets, the ΔE estimator and the CDE (correlation Doppler estimator) algorithm give similar performance. However, for nonhomogeneous scenes it is found...

  4. FORTIFICACIÓN DE PULPA DE UCHUVA CON CALCIO, OLIGOFRUCTOSA Y VITAMINA C, ESTABILIZADA CON HIDROCOLOIDE

    Directory of Open Access Journals (Sweden)

    ALBA LUCIA DUQUE

    2014-06-01

    Full Text Available La pulpa de uchuva fortificada con calcio, oligofructosa y vitamina C es un alimento funcional con grandes beneficios para la salud. Para ello se le adicionó componentes biológicamente activos, como ácidos grasos, fibra alimentaria y antioxidantes. En este trabajo se estudió la estabilidad de la pulpa enriquecida en diferentes formulaciones, teniendo en cuenta los criterios de incorporación de calcio y vitamina C (20% del valor diario recomendado VDR y para la oligofructosa (fibra dietaría en relación 1:1 con el calcio. Los resultados obtenidos mostraron que la pulpa de uchuva fortificada con CMC, ologofructosa, calcio y vitamina C presentó en promedio una estabilidad de 87,7±10,0; una viscosidad de 22,8±7,9; una aw de 0,9863±0; pH de 3,3±0,1; acidez de 1,6±0,1; grados Brix de 13,3±0,7; una densidad de 1,32±0 g/mL y las mejores respuestas sensoriales en cuanto a color, aroma, fluidez y sabor.

  5. Eco-innovation Dynamics at a Large State-Owned Wind Turbine Manufacture in China

    DEFF Research Database (Denmark)

    Yang, Yan; YIN, Shoujun

    This paper discloses the learning process and stakeholder relations in eco-innovation dynamics at a large state-owned wind turbine manufacture in China in the past 7 years. Based on an understanding of eco-innovation and eco-innovation dynamics, we propose an analytical framework of eco-innovatio......This paper discloses the learning process and stakeholder relations in eco-innovation dynamics at a large state-owned wind turbine manufacture in China in the past 7 years. Based on an understanding of eco-innovation and eco-innovation dynamics, we propose an analytical framework of eco......-innovation dynamics from a multi-perspective of learning, triple helix and path dependence. We find that, in case company’s developing wind turbine business: (1) individual and collective learning were characterized by a Do-Use-Interact mode in product innovation and assembly procedure innovation and diverse learning...... approaches were employed; (2)its product development, marketing strategy and stakeholder relations were considerably affected by central government and local government on policies, directives, regulations; (3) co-R&D with foreign companies provided it an important learning platform on product development...

  6. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The TCSP ER-2 DOPPLER RADAR (EDOP) dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of the ER-2...

  7. CAMEX-4 ER-2 DOPPLER RADAR V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 ER-2 Doppler Radar dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of ER-2. The...

  8. Functional evaluation of the urinary tract by color-Doppler ultrasonography (CDU) in 100 patients with renal colic

    Energy Technology Data Exchange (ETDEWEB)

    Pepe, Pietro E-mail: piepepe@hotmail.com; Motta, Luigi; Pennisi, Michele; Aragona, Francesco

    2005-01-01

    Introduction and objective: To evaluate if the addition of a renal color-Doppler ultrasonography (CDU) in the setting of acute renal colic improves the sensitivity of conventional sonography. Materials and methods: Between July 2002 and June 2003, 100 patients (median 49 years) with renal colic have been evaluated. Within 24 h of the admission, a CDU study of the urinary tract was performed using a sonograph GE Logiq 500 PRO with a multifrequency (3-5 MHz) convex probe. The following parameters were evaluated: ultrasonography (US) of both kidneys, ureters and bladder; resistive index (RI) of the arciform arteries of both kidneys in three different parenchymal areas; ureteric jets in response to hydration. A renal RI >0.70 and/or a 10% difference between the kidneys were considered as diagnostic of obstructive uropathy; an asymmetric and/or reduced ureteric jet from the ureteric orifices was an additional indicator of obstruction. All patients underwent a CT scan both with and without the administration of contrast medium. Results: Enhanced helical CT demonstrated an urinary stone in 90 out of the 100 patients (90%): 29 pyelic, 28 at the pyelo-ureteral junction, 23 lumbo-iliac and 10 juxtavesical stones. Among 90 patients with urolithiasis, the stone was undetectable with US in 11 cases (12.2%); in 8 cases (8.9%) pyelocalicectasis was absent, and in 6 patients (6.6%) a non-obstructive hydronephrosis was present. Median RI in obstructed and non-obstructed kidney was 0.73 (range 0.71-0.87) versus 0.62 (0.50-0.68), respectively; in two, obstructed kidneys RI was <0.70 but greater than 10% compared with normal side. Sensitivity and specificity of US, CDU (RI + ureteric jet), unenhanced helical CT and CDU in association with unenhanced helical CT were 94.8 and 55.5, 98.9 and 90.9, 100 and 100%, respectively. Discussion and conclusions: CDU in patients with renal colic and/or pelvicalicectasis improves the diagnostic accuracy of US in distinguishing between obstructive

  9. Los colores de las conchas marinas en el antiguo occidente de México. El caso del Posclásico Seashell color in ancient western Mexico. The case of the Postclassic

    Directory of Open Access Journals (Sweden)

    Luis Gómez-Gastélum

    2007-10-01

    Full Text Available A partir de los estudios sobre la cosmovisión mesoamericana -en especial aquellos relacionados con el cuerpo humano y las significaciones del color-, se analizan los patrones de uso de las conchas marinas y los objetos elaborados con éstas en las sociedades prehispánicas del occidente de México durante el periodo Posclásico (1100-1350 d.C., con la finalidad de acercarse al simbolismo que les fueron otorgados por parte de quienes las utilizaron.Based on studies of Mesoamerican cosmology, especially with regard to the human body and the meaning of color, we analyzed the use patterns of seashells and objects made from seashells in the Pre-Hispanic societies of western Mexico in the Postclassic period (1100-1530 A.D.. The goal was to understand the symbolism given to these objects by the people who utilized them.

  10. Color Doppler imaging and measurements of intraovarian and intrauterine vascularization on basal ultrasound examination in spontaneous ovulatory and anovulatory cycles

    Directory of Open Access Journals (Sweden)

    Kutlešić Ranko

    2008-01-01

    Full Text Available Background/Aim. Any organs functioning directly depends on vascularization. It applies also to the uterus and ovary which go through changes of vascularization during a menstruation cycle. The aim of this investigation was to determine differences in intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4 between spontaneous ovulatory and anovulatory cycles. Methods. This prospective clinical investigation included 205 patients divided into two groups: with ovulatory and with anovulatory cycles. Results. Resistance to ovarian arterioral stromal blood flow was significantly lower in the patients with ovulatory cycles (pulsatile index - PI 0.97 ± 0.4 vs 1.93 ± 1.37; p = 0.001737; and (resistance index - RI 0.55 ± 0.12 vs 0.68 ± 0.14; p = 0.040033. There were no statistically significant differences in arcuate arterioral blood flow in the pateints with ovulatory and anovulatory cycles (PI 1.21 ± 0.34 vs 61 ± 0,61 p = 0.136161 and RI 0.64 ± 0.11 vs 0.74 ± 0.07; p = 0.136649. The patients with ovulatory cycles had lower uterine radial arterioral blood flow than the patients with anovulatory cycles (PI 1.001 ± 0.22 vs 1.61 ± 0.23 p = 0.007501 and RI 0.55 ± 0.08 vs 0.71 ± 0.12; p = 0,0460113. The patients with ovulatory cycles had lower subendometrial arterioral blood flow resistance (PI 0.69 ± 0.19 vs 1.385±0.09; p = 0.00622 and RI 0.44 ± 0.09 vs 0.65 ± 0.02; p = 0.027458. Conclusion. Color Doppler ultrasuond imaging and measurements of intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4, showed lower resistance to blood flow in ovulatory than in anovulatory cycles.

  11. Direct Doppler auscultation of the carotid arteries

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The results of the carotid Doppler examinations and contrast arteriograms are presented. The overall sensitivity of the carotid Doppler examinations in detecting severe stenosis or occlusion of the carotid artery was 92%. The Doppler studies correctly differentiated these two conditions in 84% of the diseased vessels. In carotid arteries with stenosis greater than or equal to 50%, the sensitivity of the Doppler examinations was 90%, and these studies suggested stenosis in all but two of the 36 abnormal examinations. In two patent carotids with greater than 90% stenosis, a signal could not be elicited, presumably because of the low blood flow through the severely stenotic segment

  12. Recommendations for terminology and display for doppler echocardiography

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Doppler echocardiography has recently emerged as a major noninvasive technique with many applications in cardiology. To a large extent, this has been based upon a combination of clinical and engineering advances which now make possible the use of quantitative Doppler echocardiography in combination with two-dimensional imaging for measurement of volume flows, transvalve gradients, and other physiologic flow parameters which reflect cardiac function. It was the purpose of this Committee to provide a glossary of terms which could be used in standard fashion for papers and discussions related to Doppler echocardiography. As part of its task, the Committee also undertook an attempt to recommend a standard for display of Doppler information which would be useful, both for manufacturers and for clinicians. The document, therefore, includes: Section I, the Committee's recommendations for Doppler display. Section II, the glossary of Doppler terms, related to engineering and to clinical applications

  13. Color-coded duplex sonography in the study of thyroid pathologic conditions

    International Nuclear Information System (INIS)

    Anguissola, R.; Bozzini, A.; Campani, R.; Bottinelli, O.; Genovese, E.; Guglielmoni, B.; Fulle, I.; Bandi, G.

    1991-01-01

    The authors examined 110 patients with suspected pathologic conditions of the thyroid by means of color-coded duplex US. In addition to the information yielded by conventional US, this technique allows organ vascularization to be demonstrated. Five normal patients were considered as a control group: no tissue vascularization was demonstrated in these cases. In 8 patients presenting with carcinoma or recurrences, vascularization was markedly increased both peripheral and central to the nodule. A few doubts are still to be solved as to the diagnostic value of color-coded duplex US in the evaluation of non-carcinomas nodular pathologic conditions. As a matter of fact, non-functioning avascular adenomas can be demonstrated only in a very low percentage of cases (66%). Color-coded duplex US proved extremely sensitive and specific in depicting malignant neoplasms. Moreover, the use of fine.needle biopsy could be optimized and subsequently reduced. Color-coded duplex US proved to be markedly superior to othe rmethods and techniques in the study of thyroid diseases, especially thyroiditis and multiple pathologic conditions. The simultaneous presence of hypocapture at scintigraphy and peripheral and central vascularization in a single nodule or within multinodular struma at color-Doppler was highly suggestive of malignant thyroid neoplasm. Color-coded duplex US is a low-cost technique, which can be performed on an outpatient basis. Moreover, it is not invasive, nor does it damage the thyroid. That is why its use is almost mandatory in the study of pathologic conditions of the thyroid

  14. Consumer Acceptance of Eco-Labeled Fish: A Mexican Case Study

    OpenAIRE

    Pérez-Ramírez, Mónica; Almendarez-Hernández, Marco; Avilés-Polanco, Gerzaín; Beltrán-Morales, Luis

    2015-01-01

    Fish eco-labeling is a market-based incentive program for sustainable fisheries. This paper examines consumers’ acceptance of eco-labeled fish by using data from a pilot study conducted in a coastal area of northwestern Mexico. An ordered probit model was applied, using 364 observations. The results show that most respondents favor the idea of eco-labeled fish as a sustainable option and know that this is a costlier option. Income level, consumers’ occupation and frequency of fish consumption...

  15. MARCADORES MOLECULARES ASOCIADOS CON RESISTENCIA A LA ENFERMEDAD PUNTA MORADA EN PAPA

    Directory of Open Access Journals (Sweden)

    Ferm\\u00EDn Orona-Castro

    2009-01-01

    Full Text Available El objetivo de este trabajo fue identificar marcadores DNA Polimórfico Amplificado al Azar (RAPDs y Secuencias Simples Repetidas (SSR s también conocidos como Mi crosatélites asocia dos con la resistencia al daño causado por fitoplasmas en papa. Se evaluó la severidad de la punta morada de la papa (PMP y la apa rición de color pardo en el tubérculo, así como también se realizaron análisis moleculares en varie dades y líneas avanzadas de papa . El estudio se realizó en el laboratorio de biotecnología de la Facultad de Cie ncia s Biológicas de la Universidad Autónoma de Nuevo León - Instituto Na cional de Investigaciones Forestales Agrícolas y Pecuarias (INI FAP, México en el 2003 y 2004. Las técnicas utilizadas fueron RAPDs y SSRs también conocido microsatélites. Tres genotip os mostraron resistencia a la apa rición del color pardo deltubérculo, mie ntras que del análisis molecular seis materia les formaron un grupo que incluyó los genotip os con valores de daño mínimos (entre uno y tres de la escala. Los genotip os restantes formaron dos grupos con presencia de color pardo en el tubérculo mayor (entre cinco y siete. Se identificaron marcadores moleculares posiblemente asocia dos con tolerancia a la coloración parda del tubérculo. En el análisis de componentes principa les y el dendograma generado los materia les que presentaron menor severidad de daño, quedaron incluidos en un mismo grupo, mie ntras que materia les con mayor severidad de daño quedaron en un grupo diferente

  16. Constructing Ideologies and Valuing Nature in Two Eco-Cities

    Science.gov (United States)

    Eco-city development is flourishing as the scale and scope of environmental damage becomes increasingly clear. While there are no standard criteria of what constitutes an eco-city, the term has been increasingly applied to a number of different projects that straddle a broad arra...

  17. Hemodynamic effects of a prostacyclin analog (Prostavasin) in systemic sclero-derma patients; Effetti di un analogo della prostaciclina (Prostavasin) sui parametri Doppler nei pazienti con sclerodermia

    Energy Technology Data Exchange (ETDEWEB)

    Salera, Diego; Argalia, Giulio; Giuseppetti, Gian Marco [Univ. Politecnica delle Marche, Ancona (Italy). Istituto di radiologia

    2005-07-15

    cerebrale, retro-orbitaria e splancnica (splenoportale, mesenterica e renale) nei pazienti derodermici. Materiale e metodi. Il gruppo di studio (GS) e composto da 50 pazienti affetti da sclerodermia con anamnesi negativa per malattie cerebrovascolari, epatopatie, nefropatie e oftalmopatie. In tutti i pazienti e stata studiata la vasodilatazione endotelio-mediata dell'arteria brachiale tramite la misurazione del diametro trasverso con sonda ad alta risoluzione; sono stati anche misurati l'indice di resistenza (IR) delle arterie cerebrale media, centroretinica, epatica propria, mesenterica superiore e renali, in condizioni basali e dopo tre giorni di terapia. AI fine di valutare la variabilita intra-osservatore delle misurazioni, e stato reclutato un gruppo di controllo (GC) composto da 10 volontari sani che sono stati studiati con il medesimo protocollo Doppler e rivalutati a distanza di tre giorni senza ricevere alcuna terapia. Risultati. Il GS ha dimostrato un significativo incremento della dilatazione endotelio-mediata dell'arteria brachiale, del diametro e della velocita media di flusso portale, dell'IP dell'arteria splenica all'ilo (pre-Prostavasin vs post-Prostavasin, p < 0,001). AI contrario il GC non ha mostrato significative variazioni dei parametri considerati. Gli IR delle arterie cerebrale media, centroretinica, renale, epatica propria e mesenterica superiore si sono ridotti dopo terapia nella maggioranza dei pazienti del GS pur non risultando statisticamente significativi. Conclusioni. Nel campione esaminato il Prostavasin ha dimostrato una potente azione vasodilatatoria prevalentemente a livello periferico ed ha incrementato la velocita media di flusso portale ed il diametro della vena porta, ma anche l'IP dell'arteria splenica all'ilo, non supportando l'ipotesi formulata da altri autori di una sua azione mirata e specifica sulle resistenze intraepatiche.

  18. Optimal combinations for detection of prostate cancer: systematic sextant and laterally directed biopsies versus systematic sextant and color Doppler-targeted biopsies.

    Science.gov (United States)

    Kravchick, Sergey; Cytron, Shmuel; Peled, Ronit; London, Daniel; Sibi, Yosef; Ben-Dor, David

    2004-02-01

    To determine the accuracy of different combinations of biopsies in detecting prostate cancer. The standard sextant protocol for obtaining prostate biopsy underestimates the presence of prostate cancer. Conversely, an increased cancer detection rate has been obtained with additional laterally directed biopsies. The results of the studies dedicated to transrectal color Doppler (CD) sonography have shown that it might detect neoplastic lesions with no corresponding gray-scale abnormality. A total of 120 consecutive patients underwent sextant biopsy with additional biopsy cores taken from the lateral peripheral zone (four to six cores, depending on the prostate volume) and CD-guided biopsy. The sensitivity of laterally directed, CD-guided, and different combinations of biopsies was compared. Various patient, clinical, and pathologic factors were compared, and multivariate analysis was performed to assess the strongest predictor of cancer detection. Cancer was detected in 43 (35.8%) of 120 patients. The combination of sextant biopsy with laterally directed cores gained sensitivity to 56.6% compared with 67.4% obtained in the regimen that combined sextant and CD-guided biopsy. The CD regimen detected cancer in 11 additional patients. However, the differences in the detection rates of these combinations were not statistically significant (P = 0.797). The results of multivariate analysis showed that sextant biopsy and laterally directed cores were the strongest predictors of cancer detection (odds ratio 8.356 versus 49.282; 95% confidence interval 1.698 to 41.114 versus 10.508 to 231.130). The regimen that included sextant and CD-guided biopsy was the most sensitive. However, only standard sextant and laterally directed biopsies were statistically significant predictors of cancer detection on biopsy.

  19. PREFACE: International Symposium on Materials Science and Innovation for Sustainable Society - Eco-Materials and Eco-Innovation for Global Sustainability - The 21st Iketani Conference 2011

    Science.gov (United States)

    Takahashi, Yasuo

    2012-08-01

    Conference logo The 21st century has been called the century of environmental revolution. Green innovations and environmentally friendly production systems based on physics, chemistry, materials science, and electronic engineering will be indispensable for ensuring renewable energy and establishing a sustainable society. In particular, production design, materials processing, and fabrication technologies such as welding and joining will be very important components of such green innovations. For these reasons, the International Symposium on Materials Science and Innovation for Sustainable Society - eco-materials and eco-innovation for global sustainability - (ECO-MATES 2011) was organized by the Joining and Welding Research Institute (JWRI) and the Center of Environmental Innovation Design for Sustainability (CEIDS), Osaka University. ECO-MATES 2011 was held at Hotel Hankyu Expo Park, Osaka, Japan from 28-30 November 2011. 435 participants from 20 countries around the world attended the symposium. 149 oral presentations including 60 invited talks and 160 posters were presented at the symposium to discuss the latest research and developments in green innovations in relation to environmental issues. The topics of the symposium covered all environmentally related fields including renewable energy, energy-materials, environment and resources, waste and biomass, power electronics, semiconductor, rare-earth metals, functional materials, organic electronics materials, electronics packaging, smart processing, joining and welding, eco-efficient processes, and green applied physics and chemistry. Therefore, 55 full papers concerning green innovations and environmentally benign production were selected and approved by the editorial board and the program committee of ECO-MATES 2011. All papers were accepted through peer review processes. I believe that all the papers have many informative contents. On behalf of the steering committee of the symposium, I would like to express

  20. Chinese eco-cities, an integrated sectoral approach or an eco-cities approach?

    NARCIS (Netherlands)

    M.P. van Dijk (Meine Pieter)

    2012-01-01

    textabstractCities, aware of their environmental challenges, have introduced policies and programs to deal with issues like climate change and pollution. They want to become more ecological which would secure them the label of ‘eco-city’. Policies found in such cases are: closing the water cycle to