WorldWideScience

Sample records for computerized tomographic studies

  1. Computerized tomographic studies in cerebral palsy

    International Nuclear Information System (INIS)

    Sugie, Yoko

    1981-01-01

    Computed tomographic (CT) findings in 200 children with cerebral palsy (CP) were analysed from the viewpoint of clinical manifestations, disease complications and etiological factors. CT scans of 135 cases (67.5%) were found to be abnormal and there were 14 (7%) borderline cases. The major abnormality found on CT scans was cerebral atrophy. Other important changes included focal or diffuse low density area in the brain tissue, congenital malformation, and cerebellar atrophy. From the clinical point of view, a large number of patients with spastic tetraplegia and spastic diplegia showed highly abnormal CT scans. On the other hand, in patients with spastic monoplegia, spastic paraplegia, and athetotic type, CT findings were normal or revealed only minor cerebral atrophy. Most children showing asymmetric clinical symptoms had corresponding asymmetric CT abnormalities which included ventricular enlargement, low density area in the brain tissue, and hemispherical volume. There was a significant correlation between the severity of physical impairment and the extent of CT abnormalities. Severely affected children had grossly abnormal CT scans such as hydranencephaly, polycystic change, and extensive cerebral atrophy. In the patients complicated with epilepsy, the incidence and severity of abnormal CT were higher than those of non-epileptic patients. Mentally retarded patients had variable enlargement of the subarachnoidal space depending on the severity of their mental retardation. Patients with suspected postnatal etiology also had high incidence of severe CT abnormality. CT scan is a valuable tool for evaluating patients with CP and in some cases, possible etiology of the disease may be discovered. (author)

  2. Computerized tomographic system

    International Nuclear Information System (INIS)

    Godbarsen, R.; Barrett, D.M.; Garrott, P.M.; Foley, L.E.; Redington, R.W.; Lambert, T.W.; Edelheit, L.S.

    1981-01-01

    A computerized tomographic system for examining human breasts is described in detail. Conventional X-ray scanning apparatus has difficulty in achieving the levels of image definition and examination speeds required for mass screening. A novel method of scanning successive layers of the breast with a rotating X-ray beam is discussed and details of the control circuitry and sequence steps are given. The method involves immersing the breast in an inner fluid (e.g. water) filled container which is stationary during an examination and is surrounded by a large outer container which is also filled with the fluid; the inner and outer containers are always maintained at a constant height and the X-ray absorption across the fan-shaped beam is as close as possible to constant. (U.K.)

  3. A computerized tomographic study in patients with delusional and non-delusional depression

    International Nuclear Information System (INIS)

    Shiraishi, Hiroyasu; Koizumi, Junzo; Hori, Masashi; Terashima, Yasushi; Suzuki, Toshihito; Saito, Kiichiro; Mizukami, Katsuyoshi; Tanaka, Yoshiro; Yamaguchi, Naomi

    1992-01-01

    This is a description of a computerized tomographic study of 45 non-delusional depressed, 29 delusional depressed patients and 77 neurotic control subjects. The cerebral atrophy ratio (CAR) on the three different slices and the ventricular ratio (VBR) of the anterior horn and the body of the lateral ventricles were calculated, analyzed and compared using Student's t test. Compared to the control subjects, the non-delusional depressive patients had greater CAR values than the controls but there were no significant differences of VBR values between the two groups. The patients with delusional depression had significantly larger CAR and VBR values than the non-delusional depressives and control subjects. The delusional depressives had greater brain atrophy than the non-delusionals and it was suggested that organic cerebral factors may have etiological significance in the depressions, especially the delusional depressives. (author)

  4. Computerized tomographic diagnosis of basal skull fracture

    International Nuclear Information System (INIS)

    Tanaka, Tokutaro; Shimoyama, Ichiro; Endoh, Mitsutoshi; Ninchoji, Toshiaki; Uemura, Kenichi.

    1984-01-01

    The diagnosis of basal skull fractures used to be difficult, particularly on the basis of routine skull roentgenography alone. We have now examined the diagnostic value of conventional computerized tomography in basal skull fractures. We studied 82 cases clinically diagnosed as basal skull fractures. We examined them based on at least one of the following computerized tomographic criteria for basal skull fractures: 1) fracture line(s), 2) intracranial air, 3) fluid in the paranasal sinuses, and 4) fluid in the middle ear, including the mastoid air cells. The signs of the fracture line and of the intracranial air are definite indications of basal skull fracture, but the signs of fluid in the paranasal sinuses and/or in the middle ear are not definite. When combined, however, with such other clinical signs as black eye, Battle's sign, CSF leakage, CSF findings, and profuse nasal or ear bleeding, the diagnosis is more reliable. Seventy cases (85.4%) in this series had basal skull fractures according to our computerized tomographic criteria. Among them , 26 cases (31.7%) were diagnosed with fracture lines, 17 cases (20.7%) with intracranial air, 16 cases (19.5%) with fluid in the paranasal sinuses, 10 cases (12.2%) with fluid in the middle ear, and one case (1.2%) with fluid in both. Twelve cases (14.6%) of the 82 cases clinically diagnosed as basal skull fractures could not have been diagnosed on our computerized tomographic criteria alone. We diagnosed them because of CSF leakage, CSF findings, surgical findings, etc. (author)

  5. Computerized tomographic in non-destructive testing

    International Nuclear Information System (INIS)

    Lopes, R.T.

    1988-01-01

    The process of computerized tomography has been developed for medical imaging purposes using tomographs with X-ray, and little attention has been given to others possibles applications of technique, because of its cost. As an alternative for the problem, we constructed a Tomographic System (STAC-1), using gamma-rays, for nonmedical applications. In this work we summarize the basic theory of reconstructing images using computerized tomography and we describe the considerations leading to the development of the experimental system. The method of reconstruction image implanted in the system is the filtered backprojection or convolution, with a digital filters system to carried on a pre-filtering in the projections. The experimental system is described, with details of control and the data processing. An alternative and a complementary system, using film as a detector is shown in preliminary form . This thesis discuss and shows the theorical and practical aspects, considered in the construction of the STAC-1, and also its limitations and apllications [pt

  6. Computerized Tomographic Study on the Anatomic Variation of the Paranasal Sinus

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Kyung; Lim, Sug Young; Koh, Kwang Joon [Dept. of Oral and Maxillofacial Radiology and Institute of Oral Bio Science, College of Dentistry, Chonbuk National University, Chonju (Korea, Republic of); Park, Mi Ju [Dept. of Prosthodontics, School of Denstistry, Chonbuk National Universty, Chonju (Korea, Republic of)

    1999-08-15

    To evaluate the anatomic variations of the paranasal sinuses on computed tomographs. The author examined the CT images of the paranasal sinuses retrospectively in 500 patients who visited Chonbuk National University Hospital between January 1996 and December 1997. The highest incidence of anatomic variation of the paranasal sinuses in bilateral structures was agger nasi cell (73.2%), followed by concha bullosa (31.1%), Onodi cell (24.0%), Haller cell (19.8%), maxillary sinus septum (13.0%), paradoxical middle turbinate (2.5%), pneumatized uncinate process (2.0%), and bent uncinate process. The highest incidence of anatomic variation in midline structures was nasal septum deviation(53.2%), followed by nasal septumaerated (29.4%), bulla galli (24.7%) asymmetric intersphenoid septum (22.3%), and nasal septum spur (13.8%). The correlation between anatomic variation and paranasal sinusitis was not found. The results of this study will aid in the diagnosis and treatment of paranasal sinus diseases, especially in the treatment planning before functional endoscopic surgery.

  7. Computerized Tomographic Study on the Anatomic Variation of the Paranasal Sinus

    International Nuclear Information System (INIS)

    Choi, Sun Kyung; Lim, Sug Young; Koh, Kwang Joon; Park, Mi Ju

    1999-01-01

    To evaluate the anatomic variations of the paranasal sinuses on computed tomographs. The author examined the CT images of the paranasal sinuses retrospectively in 500 patients who visited Chonbuk National University Hospital between January 1996 and December 1997. The highest incidence of anatomic variation of the paranasal sinuses in bilateral structures was agger nasi cell (73.2%), followed by concha bullosa (31.1%), Onodi cell (24.0%), Haller cell (19.8%), maxillary sinus septum (13.0%), paradoxical middle turbinate (2.5%), pneumatized uncinate process (2.0%), and bent uncinate process. The highest incidence of anatomic variation in midline structures was nasal septum deviation(53.2%), followed by nasal septumaerated (29.4%), bulla galli (24.7%) asymmetric intersphenoid septum (22.3%), and nasal septum spur (13.8%). The correlation between anatomic variation and paranasal sinusitis was not found. The results of this study will aid in the diagnosis and treatment of paranasal sinus diseases, especially in the treatment planning before functional endoscopic surgery.

  8. Computerized tomographic simulation compared with clinical mark-up in palliative radiotherapy: A prospective study

    International Nuclear Information System (INIS)

    Haddad, Peiman; Cheung, Fred; Pond, Gregory; Easton, Debbie; Cops, Frederick; Bezjak, Andrea; McLean, Michael; Levin, Wilfred; Billingsley, Susan; Williams, Diane; Wong, Rebecca

    2006-01-01

    Purpose To evaluate the impact of computed tomographic (CT) planning in comparison to clinical mark-up (CM) for palliative radiation of chest wall metastases. Methods and Materials In patients treated with CM for chest wall bone metastases (without conventional simulation/fluoroscopy), two consecutive planning CT scans were acquired with and without an external marker to delineate the CM treatment field. The two sets of scans were fused for evaluation of clinical tumor volume (CTV) coverage by the CM technique. Under-coverage was defined as the proportion of CTV not covered by the CM 80% isodose. Results Twenty-one treatments (ribs 17, sternum 2, and scapula 2) formed the basis of our study. Due to technical reasons, comparable data between CM and CT plans were available for 19 treatments only. CM resulted in a mean CTV under-coverage of 36%. Eleven sites (58%) had an under-coverage of >20%. Mean volume of normal tissues receiving ≥80% of the dose was 5.4% in CM and 9.3% in CT plans (p = 0.017). Based on dose-volume histogram comparisons, CT planning resulted in a change of treatment technique from direct apposition to a tangential pair in 7 of 19 cases. Conclusions CT planning demonstrated a 36% under-coverage of CTV with CM of ribs and chest wall metastases

  9. Computerized tomographic scanner with shaped radiation filter

    International Nuclear Information System (INIS)

    Carlson, R.W.; Walters, R.G.

    1981-01-01

    The invention comprises a shaped filter and a filter correction circuitry for computerized tomographic scanners. The shaped filter is a generally u-shaped block of filter material which is adapted to be mounted between the source of radiation and the scan circle. The u-shaped block has a parabolic recess. The filter material may be beryllium, aluminum, sulphur, calcium, titanium, erbium, copper, and compounds including oxides and alloys thereof. The filter correction circuit comprises a first filter correction profile adding circuit for adding a first scaler valve to each intensity valve in a data line. The data line is operated on by a beam hardness correction polynomial. After the beam hardness polynomial correction operation, a second filter correction circuit adds a second filter correction profile consisting of a table of scalor values, one corresponding to each intensity reading in the data line

  10. Ultrasonic and computerized tomographic semiotics of cholelithiasis

    International Nuclear Information System (INIS)

    Kishkovskij, A.N.; Kuznetsov, S.V.; Fadeev, V.D.

    1986-01-01

    Altogether 447 patients with suspected cholelithiasis were examined by means of routine X-ray methods, ultrasound (US) and computerized tomography (CT).Of them in 104 (23.3%) chole- and/or choledocholithiasis were later confirmed. An US and CT-picture of the biliferous tracts in health were described.In cholelithiasis during US examination echogenic concrements producing a stable acoustic shadow were defined in the gall bladder cavity and/or in the biliferous ducts. A study was made of the features of the US picture with relation to size, quantity, echodensity and grouping of concrements in the biliferous ducts. CT-symptomatology of cholelithiasis was described

  11. Computerized tomographic findings in children with head trauma in ...

    African Journals Online (AJOL)

    Objective: To describe the computerized tomographic findings in children with head trauma who presented at the University of Benin Teaching Hospital, Benin City, Nigeria. Methods: It is a retrospective review of patients aged 0 – 15 years with suspected intracranial injury (ICI) following head trauma, who presented for CT ...

  12. Interictal "patchy" regional cerebral blood flow patterns in migraine patients. A single photon emission computerized tomographic study

    DEFF Research Database (Denmark)

    Friberg, L; Olesen, J; Iversen, Helle Klingenberg

    1994-01-01

    In 92 migraine patients and 44 healthy control subjects we recorded regional cerebral blood flow (rCBF) with single photon emission computerized tomography and (133) Xe inhalation or with i.v. (99m) Tc-HMPAO. Migraine patients were studied interictally. A quantitated analysis of right-left asymme......In 92 migraine patients and 44 healthy control subjects we recorded regional cerebral blood flow (rCBF) with single photon emission computerized tomography and (133) Xe inhalation or with i.v. (99m) Tc-HMPAO. Migraine patients were studied interictally. A quantitated analysis of right...... rCBF images is insufficient to pick up abnormalities; (2) almost 50% of the migraine sufferers had abnormal rCBF/asymmetries. However, these are discrete compared with those typically seen during the aura phase of a migraine attack. One explanation to the patchy rCBF patterns might...

  13. Computerized tomographic evaluation of primary brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Ok; Lee, Jong Soon; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song [Presbyterian Mediacal center, Cheonju (Korea, Republic of); Kim, Jong Deok [Inje Medical College, Paik Hospital, Pusan (Korea, Republic of)

    1985-10-15

    In a study of primary brain tumors 104 cases having satisfactory clinical, operative and histological proofs were analyzed by computerized tomography at Presbyterian Medical Center from May, 1982 to April 1985. The results were as follows: 1. The male to female ratio of primary brain tumor was 54 : 46. 2. The 2nd decade group (26%) was the most prevalent age group, followed by the 5th decade (16.3%), 1st decade (14.4%) , 3rd decade (12.5%), 4th decade (11.5%), 6th decade (10.6%), 7th decade (8.7%) in that order. 3. The incidence of primary brain tumors was found to be: glioma 64 cases (61.6%) among the GM, the most frequent 17 cases (16.3%), followed by meningioma 12 cases (11.5%), pituitary adenoma 10 cases (9.6%), craniopharyngioma 6 cases (5.8%), pinealoma and germinoma 3 cases (2.9%) respectively, and dermoid cyst 2 cases (1.9%) in that order. 4. The location of the primary brain tumors were as follows: cb. hemisphere (49%) of these 24.5% in parietal region, 11.9% in temporal region, 9.7% in frontal region, 3.0% in occipital region: juxtasella area (16.3%), cerebellar hemisphere (8.7%), parapineal and intraventricle (7.7%) respectively, cerebello-pontine angle area (5.8%), vermis and 4th ventricular region (4.8%). 5. There were no remarkable differences in the findings of pre- and post-contrast CT scanning of primary brain tumors computed with others.

  14. Neurosurgical operating computerized tomographic scanner system

    International Nuclear Information System (INIS)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi.

    1988-01-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place. (author)

  15. Development of a computerized tomographic system

    International Nuclear Information System (INIS)

    Borges, J.C.; Santos, C.A.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory at COPPE/UFRJ has been developing techniques for detection and applications of nuclear radiations. A lot of research work has been done and resulted in several M.Sc. and D.Sc. thesis, concerning subjects like neutrongraphy, gammagraphy, image reconstruction, special detectors, etc. Recent progress and multiple applications of the computerized tomography to medical and industrial non-destructive tests, pushed the Laboratory to a vast program in this field of research. In this paper, we report what has been done and the results obtained. (Author) [pt

  16. Computerized tomographic evaluation of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Young; Lee, Mi Sook; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song [Precbyterian Medical Center, Chonju (Korea, Republic of)

    1988-08-15

    Cerebral cysticercosis, unfortunately frequent in Korea, is a parastic disease in which man serve as the intermediate host of taenia solium. The larvae have a predilection for the central nervous system and can cause a variety of neurologic symptoms. The authors reviewed 19 cases of surgically proven cerebral cysticercosis and following results were obtained. 1. The most frequent age distribution was 5th and 6th decade and male to female ratio was 14:5. 2. The most frevalent involving site was cerebral parenchyme and following by ventricles. 3. Clinical manifestations were symtom and sign of increased ICP, seizure and focal neurological dificit. 4. It was assumed that computerized tomography was the procedure of choice for the diagnosis of these parasitic brain disease.

  17. Computerized tomographic quantification of chronic obstructive pulmonary disease as the principal determinant of frontal P vector.

    Science.gov (United States)

    Chhabra, Lovely; Sareen, Pooja; Gandagule, Amit; Spodick, David

    2012-04-01

    Verticalization of the P-wave axis is characteristic of chronic obstructive pulmonary disease (COPD). We studied the correlation of P-wave axis and computerized tomographically quantified emphysema in patients with COPD/emphysema. Individual correlation of P-wave axis with different structural types of emphysema was also studied. High-resolution computerized tomographic scans of 23 patients >45 years old with known COPD were reviewed to assess the type and extent of emphysema using computerized tomographic densitometric parameters. Electrocardiograms were then independently reviewed and the P-wave axis was calculated in customary fashion. Degree of the P vector (DOPV) and radiographic percent emphysematous area (RPEA) were compared for statistical correlation. The P vector and RPEA were also directly compared to the forced expiratory volume at 1 second. RPEA and the P vector had a significant positive correlation in all patients (r = +0.77, p <0.0001) but correlation was very strong in patients with predominant lower lobe emphysema (r = +0.89, p <0.001). Forced expiratory volume at 1 second and the P vector had almost a linear inverse correlation in predominantly lower lobe emphysema (r = -0.92, p <0.001). DOPV positively correlated with radiographically quantified emphysema. DOPV and RPEA were strong predictors of qualitative lung function in patients with predominantly lower lobe emphysema. In conclusion, a combination of high DOPV and predominantly lower lobe emphysema indicates severe obstructive lung dysfunction in patients with COPD. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Development of a computerized tomographic system based on the FAN-BEAM technique

    International Nuclear Information System (INIS)

    Junqueira, M.M.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory, at COPPE/UFRJ, concentrates its researches in the development of computerized tomographic systems, looking for applications in industrial and medical non destructive analysing techniques. In this work we have projected and constructed a tomographic prototype, based on the FAN-BEAM technique for irradiating the object under analysis. An algorithm previously developed to analyse parallel beams, was modified and adapted to the FAN-BEAM geometry. (Author) [pt

  19. Computerized tomographic evaluation of aortic prosthetic graft complications

    International Nuclear Information System (INIS)

    Kay, D.; Kalmar, J.A.

    1985-01-01

    Computerized tomography has been found to be an accurate and sensitive method of diagnosing complications of synthetic aortic grafts. Complications in this series of four cases included aortoesophageal fistula, aortoduodenal fistula, pseudoaneurysm, and retroperitoneal hematoma. 6 references, 5 figures

  20. ECAT: a new computerized tomographic imaging system for position-emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Phelps, M.E.; Hoffman, E.J.; Huang, S.C.; Kuhl, D.E.

    1977-01-01

    The ECAT was designed and developed as a complete computerized positron radionuclide imaging system capable of providing high contrast, high resolution, quantitative images in 2 dimensional and tomographic formats. Flexibility, in its various image mode options, allows it to be used for a wide variety of imaging problems

  1. Spiral Computed Tomographic Imaging Related to Computerized Ultrasonographic Images of Carotid Plaque Morphology and Histology

    DEFF Research Database (Denmark)

    Grønholdt, Marie-Louise M.; Wagner, Aase; Wiebe, Britt M.

    2001-01-01

    Echolucency of carotid atherosclerotic plaques, as evaluated by computerized B-mode ultrasonographic images, has been associated with an increased incidence of brain infarcts on cerebral computed tomographic scans. We tested the hypotheses that characterization of carotid plaques on spiral comput...

  2. Positron transaxial emission tomograph with computerized image reconstruction

    International Nuclear Information System (INIS)

    Jatteau, Michel.

    1981-01-01

    This invention concerns a positron transaxial emission tomography apparatus with computerized image reconstruction, like those used in nuclear medicine for studying the metabolism of organs, in physiological examinations and as a diagnosis aid. The operation is based on the principle of the detection of photons emitted when the positrons are annihilated by impact with an electron. The appliance is mainly composed of: (a) - a set of gamma ray detectors distributed on a polygonal arrangement around the body area to be examined, (b) - circuits for amplifying the signals delivered by the gamma ray detectors, (c) - computers essentially comprising energy integration and discrimination circuits and provided at the output of the detectors for calculating and delivering, as from the amplified signals, information on the position and energy relative to each occurrence constituted by the detections of photons, (d) - time coincidence circuits for selecting by emission of detector validation signals, only those occurrences, among the ensemble of those detected, which effectively result from the annihilation of positrons inside the area examined, (e) - a data processing system [fr

  3. Cardiac imaging systems and methods employing computerized tomographic scanning

    International Nuclear Information System (INIS)

    Richey, J.B.; Wake, R.H.; Walters, R.G.; Hunt, W.F.; Cool, S.L.

    1980-01-01

    The invention relates to cardiac imaging systems and methods employing computerised tomographic scanning. Apparatus is described which allows an image of the radiation attenuation of the heart at a desired phase of the cardiac cycle. The patients ECG signal can be used in a transverse-and-rotate type CT scanner as a time base, so that the beam reaches the heart at a desired phase of the cardiac cycle, or, in a purely rotational-type CT scanner continuously generated scan data is only stored for corresponding phases of successive cardiac cycles. Alternatively, gating of the beams themselves by shuttering or switching the power supply can be controlled by the ECG signal. A pacemaker is used to stabilize the cardiac period. Also used is a system for recognising unacceptable variations in the cardiac period and discarding corresponding scan data. In a transverse-and-rotate type fan-beam CT scanner, the effective beam width is narrowed to reduce the duration of the traverse of the heart. (U.K.)

  4. Anatomical Variations of Carotid Artery and Optic Nerve in Sphenoid Sinus Using Computerized Tomographic Imaging

    Directory of Open Access Journals (Sweden)

    Nikakhlagh

    2014-12-01

    Full Text Available Background Sphenoid sinus is surrounded by many vital vascular and nervous structures. In more than 20% of patients with chronic sinusitis, involvement of sphenoid sinus has been observed. Besides, sphenoid sinus is an appropriate route to access anterior and middle cranial fossa in surgery. Therefore, it is important to have an adequate knowledge about the contents of sphenoid sinus and its proximity for nasal endoscopy, sinus surgeries and neurosurgeries. Objectives The aim of this study was to study sphenoid sinus proximity with carotid artery and the optic nerve using computerized tomographic imaging. Materials and Methods In this prospective study, computerized tomographic images of sphenoid sinus of patients referred to Imam Khomeini and Apadana hospitals were studied. The images were studied regarding any bulging, as well as not having a bone covering in sphenoid sinus regarding internal carotid artery and optic nerve. Furthermore, unilateralness or bilateralness of their relationships was studied. Results Among 468 coronal and axial CT scan images of sphenoid sinus, 365 (78% showed post-sellar pneumatization and 103 (22% pre-sellar pneumatization. Regarding existence of internal septa, 346 (74% cases showed multiple septation, and the remaining images were reported to have a single septum. According to the reports of CT scan images, the existence of bulging as a result of internal carotid artery and uncovered artery were 4.22% and 5.8% in the right sinus, 4.9% and 5.4% in the left sinus, and 4.34% and 4.6% in both sinuses, respectively. According to the reports of CT scan images, existence of bulging as a result of optic nerve and uncovered nerve were 5.7% and 4.3% in the right sinus, 6% and 5.4% in the left sinus, and 12% and 3.2% in both sinuses, respectively. Conclusions Due to variability of sphenoid sinus pneumatization and the separator blade of the two sinus cavities, careful attention is required during sinus surgery to avoid

  5. Tay-Sachs disease with conspicuous cranial computerized tomographic appearances

    International Nuclear Information System (INIS)

    Watanabe, Kishichiro; Mukawa, Akio; Muto, Kazuhiko; Nishikawa, Jiro; Takahashi, Shigeko.

    1985-01-01

    An autopsy case of a 3-year-old female infant with Tay-Sachs disease was presented. A cherry red spot in the fundus and a deficiency of N-acetyl-β-hexosaminidase A in the white blood cells were revealed soon after admission at the age of one year. Her parents and sister were found to be healthy carriers. The patient showed a typical clinical course with marked cranial swelling. In addition to the marked ballooning of neurons on light microscope, membranous cytoplasmic body (MCB) on electron microscope and abnormal accumulation of GM 2 ganglioside in the cerebral cortex by thin layer chromatography were confirmed in the autopsy specimens. In the late stage of her clinical course, the cranial computerized tomography (CT) demonstrated symmetric and deep-wavy hyperdense cerebral cortical zones, diffuse hypodensity and diminished volume of cerebral white matter, mild to moderate ventricular dilatation, and a small cerebellum and brainstem. These conspicuous appearances of the cranial CT seem to be characteristic of Tay-Sachs disease in the late stage, and they are derived from abnormal accumulation of GM 2 ganglioside in the cerebral cortex, and diffuse intense demyelination (dysmyelinating demyelination) of the cerebral white matter. (author)

  6. Multidetector computerized tomographic fistulography in the evaluation of congenital branchial cleft fistulae and sinuses.

    Science.gov (United States)

    Sun, Zhipeng; Fu, Kaiyuan; Zhang, Zuyan; Zhao, Yanping; Ma, Xuchen

    2012-05-01

    The aim of this study was to primarily investigate the usefulness of computerized tomographic (CT) fistulography in the diagnosis and management of branchial cleft fistulae and sinuses. Fifteen patients with confirmed branchial fistulae or sinuses who had undergone CT fistulography were included. The diagnoses were confirmed by clinical, radiologic, or histopathologic examinations. The internal openings, distribution, and neighboring relationship of the lesions presented by CT fistulography were analyzed to evaluate the usefulness in comparison with x-ray fistulography. Nine patients were diagnosed with first branchial fistulae or sinuses, 2 with second branchial fistulae, and 4 with third or fourth branchial fistulae. The presence and location of the lesions could be seen on x-ray fistulography. The distribution of the lesions, internal openings, and neighboring relationship with parotid gland, carotid sheath, and submandibular gland could be clearly demonstrated on CT cross-sectional or volume-rendering images. CT fistulography could provide valuable information and benefit surgical planning by demonstrating the courses of branchial anomalies in detail. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Chronic subdural hematoma fluid and its computerized tomographic density

    International Nuclear Information System (INIS)

    Masuzawa, Hideaki; Sato, Jinichi; Kamitani, Hiroshi; Yamashita, Midori

    1983-01-01

    Laboratory and in vivo CT analysis were performed on 19 chronic subdural hematomas and five subdural hygromas. In these 25 hematoma samples, red blood cells (RBC), hematocrit, and hemoglobin (Hgb) varied greatly, though, these values correlated well with the CT densities. Plasma protein content was fairly constant with an average of 7.1+-0.8g/dl. There were four hematoma samples with RBC of less than 20x10 4 μl or Hgb of less than 2.0g/dl. Their CT values ranged between 18 and 23 H.U., which were considered close to the in vivo serum level CT density. Five hygroma fluid showed no RBC and very little protein content of less than 0.4g/dl. CT density ranged between -2 and 13 H.U. The edge effect of the skull was experimentally studied using a phantom skull filled with water. This revealed a remarkable overshoot of the CT values within ten pixels from the inner wall of the skull. Visual observation of the original CT pictures revealed four low density hematomas and seven mixed density ones. When compared to the density of the ventricular cavity, all of the low density hematomas and the supernatant part of the mixed density ones were clearly higher in density. All five hygromas appeared CSF dense or lower. In conclusion, because of the edge effect by the skull, thin subdural fluids could not be diagnosed by CT alone. Thick subdural fluids could be differentiated as either hematoma or hygroma by their CT densities. Subdural hematomas had in vivo CT densities of at least serum level or approximately 20 H.U., while subdural hygromas had densities close to CSF. These characteristics were best appreciated by visual observation of the CT scan films. (J.P.N.)

  8. The influence of the periodontal biotype on peri-implant tissues around immediate implants with and without xenografts. Clinical and micro-computerized tomographic study in small Beagle dogs.

    Science.gov (United States)

    Maia, Luciana P; Reino, Danilo M; Muglia, Valdir A; de Souza, Sérgio L S; Palioto, Daniela B; Novaes, Arthur B

    2015-01-01

    Soft tissues and buccal bone plate remodeling after immediate implantation in sockets with thin buccal bone, using the flapless approach with or without bone graft into the buccal gap, was compared between sites with thin and normal gingiva. Eight dogs had the gingiva of one side of the mandible thinned, the mandibular premolars were extracted without flaps, and 4 implants were installed in each side, positioned 1.5 mm from the buccal bone. The sites were randomly assigned into: TG (test group) = thin gingiva; TG + GM (TG with grafting material); CG (control group) = normal gingiva; and CG + GM (CG with grafting material). Buccal bone thickness (BBT), thickness of keratinized tissue (TKT), alveolar thickness (AT), gingival recession (GR), and probing depth (PD) were clinically evaluated. Within 12 weeks the dogs were sacrificed and the samples were analyzed by micro-computerized tomography. A thin BBT was observed in all the dogs. The presurgical procedures reduced TKT in the test group, with minimal changes of the AT. There were no statistically significant differences among the groups for the clinical parameters and the tomographic analysis showed similar linear and tri-dimensional bone reduction in all the groups. The thickness of the buccal bone was a fundamental factor in buccal bone plate resorption, even with flapless implantation. The decrease in gingival thickness or the addition of a biomaterial in the gap did not influence the results. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Computerized tomographic findings of hepatic fascioliasis compared with melioidosis-caused liver abscesses.

    Science.gov (United States)

    Chamadol, Nittaya; Laopaiboon, Vallop; Techasatian, Pennapa; Sukeepaisanjaroen, Wattana; Sripanuskul, Anan

    2010-07-01

    To compare the computerized tomographic (CT) findings of hepatic fascioliasis (HF) vs. melioidosis-caused liver (ML) abscesses. CT images of 15 patients with hepatic fascioliasis (HF) and 16 patients with melioidosis-caused liver (ML) abscesses were retrospectively reviewed. The authors evaluated and compared HF and ML abscesses (by chi2 and Fisher exact tests) vis-a-vis their location of liver involvement, size, shape, number margins, enhancement patterns, subcapsular lesions, internal architecture, dilatation of intrahepatic bile duct and combination with splenic abscesses. Fourteen HF patients had only liver abscesses and 1 had combined liver and splenic abscesses. Four ML patients had liver abscesses alone while 12 had combined liver and splenic abscesses (p = 0.000). Eight of the 15 HF (53.3%) and 2 of the 16 ML (12.5%) patients had subcapsular lesions (p = 0.019). The liver abscesses were round or oval with linear tracts in 8 of the 15 HF (53.3%) and none of the ML patients (p = 0.001). Between the respective HF and ML patients, there was a significant difference in those with round shaped in ML (p = 0.008), multiple and conglomerately distributed in HF (p = 0.050), multiple and discretely distributed in ML (p = 0.001) no (or minimal) peripheral contrast enhancement in HF (p = 0.011) and moderate or mark peripheral enhancement in ML (p = 0.011). The CT findings of liver abscesses that helped to differentiate hepatic fascioliasis from melioidosis liver abscesses were: their number shape, enhancement pattern, presence of subcapsular lesion (s) and co-occurrence with splenic abscesses. The diagnosis of hepatic fascioliasis by CT is suggested when the following characteristics were seen: (1) multiple, small round or oval (with linear tracts) conglomerates presenting as hypodense lesions; (2) no (or minimal) peripheral contrast enhancement; (3) subcapsular lesions; or (4) less frequent co-occurrence with splenic abscesses.

  10. Motion-Computerized Tomographic Colography is a Better Method for Screening for Polyps: Arguments for the Motion

    Directory of Open Access Journals (Sweden)

    Benoit C Pineau

    2003-01-01

    Full Text Available Colorectal cancer is an important public health problem that is amenable to prevention and early treatment. Traditional screening techniques - fecal occult blood testing, flexible sigmoidoscopy, barium enema and colonoscopy - each have limitations in terms of diagnostic accuracy, cost and/or patient acceptability. Compliance with recommendations for screening has been poor, in part, because of negative perceptions about the available modalities. Virtual colonoscopy, or computerized tomographic colography, is a minimally invasive technique that safely evaluates the entire colon and does not require sedation. Thorough cleansing as well as immobilization and air insufflation of the colon is crucial to a successful examination. Sensitivity and specificity rates are reasonable, compared with conventional colonoscopy, and it has been shown that the latter technique can be averted in over two-thirds of cases, with few false-negative examinations. Most patients find virtual colonoscopy more acceptable than the conventional technique, and would prefer it if a repeat procedure were warranted. An economic analysis that found that computerized tomographic colography was less cost effective than conventional colonoscopy did not consider the indirect costs of the latter, which is an important limitation. Virtual colonoscopy is a novel radiological technique that may revolutionize screening for colorectal cancer.

  11. Thoracic computerized tomographic (CT findings in 2009 influenza A (H1N1 virus infection in Isfahan, Iran

    Directory of Open Access Journals (Sweden)

    Mojtaba Rostami

    2011-01-01

    Full Text Available Background: Pandemic 2009 H1N1 influenza A virus arrived at Isfahan in August 2009. The virus is still circulating in the world. The abnormal thoracic computerized tomographic (CT scan findings vary widely among the studies of 2009 H1N1 influenza. We evaluated the thoracic CT findings in patients with 2009 H1N1 virus infection to describe findings compared to previously reported findings, and to suggest patterns that may be suggestive for 2009 influenza A (H1N1 in an appropriate clinical setting. Methods: Retrospectively, the archive of all patients with a diagnosis of 2009 H1N1 influenza A were reviewed, in Al-Zahra Hospital in Isfahan, central Iran, between September 23 rd 2009 to February 20 th 2010. Out of 216 patients with confirmed 2009 influenza A (H1N1 virus, 26 cases with abnormal CT were enrolled in the study. Radiologic findings were characterized by the type and pattern of opacities and zonal distribution. Results: Patchy infiltration (34.6%, lobar consolidation (30.8%, and interstitial infiltration (26.9% with airbronchogram (38.5% were the predominant findings in our patients. Bilateral distribution was seen in 80.8% of the patients. Only one patient (3.8% showed ground-glass opacity, predominant radiographic finding in the previous reports and severe acute respiratory syndrome (SARS. Conclusions: The most common thoracic CT findings in pandemic H1N1 were patchy infiltration, lobar consolidation, and interstitial infiltration with airbronchogram and bilateral distribution. While these findings can be associated with other infections; they may be suggestive to 2009 influenza A (H1N1 in the appropriate clinical setting. Various radiographic patterns can be seen in thoracic CT scans of the influenza patients. Imaging findings are nonspecific.

  12. Regional aspects of cerebral cysticercosis. Incidence and evaluation by computerized tomography in 1000 consecutive studies

    Energy Technology Data Exchange (ETDEWEB)

    Jozzolino, D.A. (Instituto de Tomografia Axial Computadorizada de Londrina (Brazil))

    One thousand consecutive studies of the entire brain were performed and 122 patients with tomographic diagnosis of cysticercosis were found. The high incidence of this disease is discussed and its endemic characteristics as well. Various forms and types are described, the most frequent being the presence of calcifications; other tests performed at the time of computerized tomography are mentioned.

  13. A 5-year clinical and computerized tomographic implant follow-up in sinus-lifted maxillae and native bone.

    Science.gov (United States)

    Sbordone, Carolina; Toti, Paolo; Ramaglia, Luca; Guidetti, Franco; Sbordone, Ludovico; Martuscelli, Ranieri

    2014-09-01

    The present study analysed apical and marginal bone remodelling around dental implants placed in both maxillary (sinus elevated with particulated autogenous osseous graft) and corresponding native bone areas, with a follow-up of 5 years. The clinical survival of implants was also observed. In this retrospective chart review, 27 patients were enrolled, with 55 dental implants inserted from 2000 to 2006, 26 of which were followed (one implant per patient); if required, patients were treated via sinus lift with autogenous bone and particulate technique. The internal controls were implants positioned in native areas beneath the sinus. Radiologic survey was assessed via computerized tomographic analysis measuring apical bone level (ABL) and marginal bone level (MBL), at 1- (T1 ), 3- (T2 ) and 5 years (T3 ), around implants (buccal, b; palatal, p; mesial, m; and distal sides, d). Clinical probing depth (CPD) and clinical attachment level (CAL) for all the four peri-implant aspects were measured. Cumulative survival rate (CSR) and survival rate (SR) of implants were calculated. Significances for paired and unpaired comparisons were searched for. A significant degree of apical resorption was recorded between T1 and T3 for the mesial particulate group; again, a significant difference was discovered between the native and particulate procedures for mABL. A further feature was discovered for the particulate procedure, for which ABLs resulted negative at least for three of the aspects. Regarding MBL measurements, similar behaviours were revealed using time-comparison analysis for the two procedures at the buccal aspect. Comparisons among diameters, irrespective of the procedure, showed that resorption times for the bMBL were shorter as the diameter of the implant became wider. The implant CSR was 92% in native areas (two failures/25 implants) and 93.3% in sinuses lifted with particulate bone (two failures/30 implants). The results suggest that a protrusion of the implant

  14. Neurosurgical operating computerized tomographic scanner system. The CT scanner in the operating theater

    Energy Technology Data Exchange (ETDEWEB)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi

    1988-12-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place.

  15. Carotid ultrasonographic and brain computerized tomographic findings in patients with vascular ocular syndromes

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, Toshihiko; Matsushima, Chikage; Shimizu, Souichirou; Takasaki, Masaru; Iwasaki, Takuya; Usui, Masahiko [Tokyo Medical Coll. (Japan)

    2002-02-01

    To clarify the characteristics of cerebrovascular lesions in subtypes of vascular ocular syndrome, including amaurosis fugax (AF), retinal artery occlusion (RAO), and retinal vein occlusion (RVO), 93 patients with vascular ocular syndrome were studied by means of carotid ultrasonography (US) and brain computerized tomography (CT). The subjects comprised 21 patients with AF, 37 with RAO, and 35 with RVO who were sequentially given these diagnoses by the department of ophthalmology. On the basis of US findings, carotid lesions were defined as the presence of plaque or stenotic changes. CT findings were assessed for the presence and distribution of low-density areas (LDAs). Mean age was similar in each group, ranging from 64.5 to 67.4 years. The RAO group had high rates of men, hypertension, and smokers. US showed that the prevalence of carotid lesions ipsilateral to the affected eye was high in the RAO group and that severe stenosis and ulcerated plaque were present in 28.6% of the AF group and 45.9% of the RAO group. On CT examination, cerebral infarctions appeared as LDAs in about 10% of the patients in each group, and the incidence and distribution of LDAs were similar. Of 13 patients with cerebral infarction, only 2 were presumably due to carotid lesions; the others had a variety of causes. The discrepancy between US and CT findings was attributed to the small number of patients with cerebral infarction, since most patients had visual defects as an initial symptom. Our results suggest that extracranial carotid lesions, considered to be a major risk factor for stroke, should be carefully assessed in patients with AF or RAO to prevent further stroke. (author)

  16. Computerized tomographic visualization of niveau by turning the head in a case of pituitary apoplexy

    International Nuclear Information System (INIS)

    Sasajima, Toshio; Mineura, Katsuyoshi; Kowada, Masayoshi; Sasaki, Junko; Sasajima, Hiroyasu; Sakamoto, Tetsuya

    1987-01-01

    A case of pituitary apoplexy is presented in which a free niveau formation, a pathognomonic sign of this entity, was proved by means of computerized tomography (CT) by turning the head. A 48-year-old female had developed a sudden, excruciating, retroorbital headache, vomiting, and visual disturbance twice prior to admission. The visual acuity was 0.1 in the right eye and 0.6 in the left eye. The optic fundi were normal. There was a right temporal field loss and a left upper temporal quadrantanopsia. A plain skull film disclosed ballooning and a double floor of the turcic sella. A CT scan of the head, performed by means of a GE CT/T 8800 Scanner, showed an intrasellar low-density mass with a slightly enhanced rim. We were not convinced of the presence of a high-density area, though there seemed to be one adjacent to the posterior clinoid process and the turcic floor, because of the partial volume effect and the artifact related to the neighboring bones. Another high-resolution CT scan on the ensuing day, as the head was turned and then kept still at about 45 degrees to the right, while the patient was supine, for ten minutes, made it possible to visualize a free fluid level, comparable to a fluid-blood-density level. A transsphenoidal pituitary exploration identified blood fluid collection in the encapsulated tumor, a finding which was histologically consistent with the sinusoidal type of chromophobe adenoma. There was some microscopic evidence of necrosis and hemosiderin laden cells. The postoperative course was uneventful; visual acuity improved without delay, and the temporal field defect became significantly smaller. Two weeks later, visual acuity had recovered to 1.2 uncorrected in each eye. CT and the pertinent position of the head might be quite helpful for the visualization and confirmation of a subtle free fluid level in cases of pituitary apoplexy. (author)

  17. The use of transport and diffusion equations in the three-dimensional reconstruction of computerized tomographic images

    Energy Technology Data Exchange (ETDEWEB)

    Pires, Sandrerley Ramos, E-mail: sandrerley@eee.ufg.br [Escola de Engenharia Eletrica e de Computacao - EEEC, Universidade Federal de Goias - UFG, Goiania, GO (Brazil); Flores, Edna Lucia; Pires, Dulcineia Goncalves F.; Carrijo, Gilberto Arantes; Veiga, Antonio Claudio Paschoarelli [Faculdade de Engenharia Eletrica - FEELT, Universidade Federal de Uberlandia - UFU, Uberlandia, MG (Brazil); Barcelos, Celia Aparecida Z. [Faculdade de Matematica, Universidade Federal de Uberlandia - UFU, Uberlandia, MG (Brazil)

    2012-09-15

    The visualization of a computerized tomographic (TC) exam in 3D increases the quality of the medical diagnosis and, consequently, the success probability in the treatment. To obtain a high quality image it is necessary to obtain slices which are close to one another. Motivated towards the goal of reaching an improved balance between quantity of slices and visualization quality, this research work presents a digital inpainting technique of 3D interpolation for CT slices used in the visualization of human body structures. The inpainting is carried out via non-linear partial differential equations (PDE). The PDE's have been used, in the image-processing context to fill in the damaged regions in a digital 2D image. Inspired by this idea, this article proposes an interpolation method for the filling in of the empty regions between the CT slices. To do it, considering the high similarity between two consecutive real slice, the first step of the proposed method is to create the virtual slices. The virtual slices contain all similarity between the intercalated slices and, when there are not similarities between real slices, the virtual slices will contain indefinite portions. In the second step of the proposed method, the created virtual slices will be used together with the real slices images, in the reconstruction of the structure in three dimensions, mapped onto the exam. The proposed method is capable of reconstructing the curvatures of the patient's internal structures without using slices that are close to one another. The experiments carried out show the proposed method's efficiency. (author)

  18. Clinical and computerized tomographic studies of chronic subdural hematomas

    International Nuclear Information System (INIS)

    Naito, Takahiro; Maegawa, Mototsugu; Morimoto, Tetsuya; Sakaki, Toshisuke; Tanikake, Tatsuo

    1981-01-01

    The authors' experience is based on 84 patients with chronic subdural hematomas verified by surgery. Analysis of CT findings of the chronic subdural hematoma led to a classification of four different types: low, iso-, mixed and high density. The mixed density type was classified into two subdivisions: Type I characterized by the sharp border between two compartments and Type II characterized by high density around the hematoma capsule. There was tendency in the high density type group for the clinical course from onset to be the most rapid, the mass effect for the brain the strongest and the period from onset to surgical intervention the shortest. They were slower, weaker and longer in order of the mixed, iso- and low density types. As a result of analysis of hematoma content, there was no correlation among Ca ion concentration, total protein volume and types of hematoma, but there were some significant correlations among hemoglobin, hematocrit and types of hematoma. Hemoglobin and hematocrit were highest in hematoma content of the high density type and were lower in the order of the high density part of the mixed density type, isodensity type and low density type. However, the hematoma content in the low density type showed the highest value of LDH. (author)

  19. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  20. Computerized tomographic evaluation of chronic ischemic lesions in cerebral white matter

    International Nuclear Information System (INIS)

    Yamanouchi, Hiroshi; Tohgi, Hideo; Iio, Masahiro; Tomonaga, Masanori.

    1981-01-01

    The purpose of this study is to clarify the correlation between the low density areas and periventricular lucency (PVL) on CT and the histopathologic changes of chronic ischemic lesions in cerebral white matter. Thirty seven brains from chronic cases with stroke and 17 brains from patients who showed PVLs on CT were examined histologically. CT scans were performed using GE CT/T. Chronic ischemic lesions with severe demyelination or diffuse cavitation were detected as low density areas on CT. But if associated with severe gliosis, those lesions could not be detected on CT. Areas with myelin pallor could not be detected on CT. In some cases diffuse ischemic lesions as demyelination and cavitation were found in the areas corresponding to PVLs on CT. However, they were not always expressed on CT. Other cases with PVL had no histological changes in the frontal white matter. In conclusion, chronic ischemic lesions in the cerebral white matter could not always be detected as low density areas on CT. This may be partly because decreased density due to demyelination and cavitation was counterbalanced by severe gliosis which tends to increase the density. In some cases PVLs were related to diffuse ischemic lesions in the frontal white matter, but this was not always the case. (author)

  1. Comparative study of the macroscopic finding, conventional tomographic imaging, and computed tomographic imaging in locating the mandibular canal

    International Nuclear Information System (INIS)

    Choi, Hang Moon; You, Dong Soo

    1995-01-01

    The purpose of this study was comparison of conventional tomography with reformatted computed tomography for dental implant in locating the mandibular canal. Five dogs were used and after conventional tomographs and fitted computed tomographs were taken, four dentist traced all films. Mandibles were sectioned with 2 mm slice thickness and the sections were then radiographed (contact radiography). Each radiograpic image was traced and linear measurements were made from mandibular canal to alveolar crest, buccal cortex, lingual cortex, and inferior border. The following results were obtained; 1. Reformatted computed tomographs were exacter than conventional tomography by alveolar crest to canal length of -0.6 mm difference between real values and radiographs 2. The average measurements of buccal cortex to mandibular canal width and lingual cortex to mandibular canal width of conventional tomographs were exacter than reformatted computed tomographs, but standard deviations were higher than reformatted computed tomographs. 3. Standard deviations of reformatted computed tomographs were lower than conventional tomographs at all comparing sites 4. At reformatted computed tomography 62.5% of the measurements performed were within ±1 mm of the true value, and at conventional tomography 24.1% were. 5. Mandibular canal invisibility was 0.8% at reformatted computed tomography and 9.2% at conventional tomography. Reformatted computed tomography has been shown to be more useful radiographic technique for assessment of the mandibular canal than conventional tomography.

  2. Study of computerized tomography using neutron beam

    International Nuclear Information System (INIS)

    Pereira, W.W.

    1991-05-01

    This paper aims to demonstrate the advantages, shortcomings and complementaries of a tomography development using neutrons over the one employing gamma rays in the context of their applications to non destructive essays. A simulated experimental study was performed in order to compare the two aforementioned tomographic procedures as applied to some materials. These materials were chosen for their clear advantages and complementaries as, for instance, aluminium, iron, plastic and aluminium hydroxide. In this work two tomographic systems, are employed both with parallel beams. The first with a gamma radiation source (Caesium-137), with an energy of 662 KeV and an activity of 3,9 x 10 9 Bq (100 mCi) and the second one employing a neutron source, the Argonaut Reactor of the Instituto de Engenharia Nuclear, IEN/CNEN, from where the thermal neutron beam of about 10 5 n/(cm.s) was obtained. It is possible to conclude from the simulated and experimental results, by means of image analysis and distortion measurements, that for a given material the adequate radiation and its energy may be chosen so as to better characterize it. (author)

  3. Computed tomographic study in children with microcephaly

    International Nuclear Information System (INIS)

    Ito, Masatoshi; Okuno, Takehiko; Mikawa, Haruki

    1989-01-01

    Computed tomographic (CT) brain scanning was performed on fifty-eight infants and children with microcephaly. CT scans were useful for detecting unsuspected brain lesions and for diagnosing underlying diseases. The head size did not correlate with the CT findings, the degree of mental retardation, or the existence of motor disturbance or epilepsy. On the other hand, the CT findings were correlated with the degree of mental retardation, and the existence of motor disturbance or epilepsy. CT scans were useful for determining the prognosis of the microcephaly. (author)

  4. Study of the human encephalon morphology by computerized axial tomography in neurological diseases

    International Nuclear Information System (INIS)

    Loynaz Fernandez, Clara Silvia; Milan Companioni, Daile; Gomez Padron, Ivo; Alvarez Leon, Oladys; Espinosa Quiros, Desiderio

    2001-01-01

    Since the middle of the last century, the study of the human encephalon morphology has been of great interest for the researchers. With the introduction of the computerized axial tomography in 1974, it was possible to expand the knowledge about this area and at the same time provide information on the structural lesions that are pathologies of great psychosocial repercussion like epilepsy and Parkinsonism. This paper used 90 tomographic studies on people aged 20-80 years. A series of linear measurements were made and statistically processed. The results showed variations in linear measurements among control, epileptic and Parkinsonian subjects

  5. Detection of the source of hemorrhage using postmortem computerized tomographic angiography in a case of a giant juvenile nasopharyngeal angiofibroma after surgical treatment.

    Science.gov (United States)

    do Nascimento, Felipe Barjud Pereira; dos Santos, Glaucia Aparecida Bento; Melo, Nelson Almeida d'Ávila; Damasceno, Eduarda Bittencourt; Mauad, Thais

    2015-09-01

    Postmortem computerized tomographic angiography (PMCTA) has been increasingly used in forensic medicine to detect and locate the source of bleeding in cases of fatal acute hemorrhage. In this paper, we report a case of postoperative complication in a patient with a giant juvenile nasopharyngeal angiofibroma in which the source of bleeding was detected by PMCTA. A case description and evaluations of the pre- and postoperative exams, postmortem CT angiogram, and conventional autopsy results are provided. The source of bleeding was identified by postmortem CT angiography but not by conventional autopsy. The established protocol, injecting contrast medium into the femoral artery, was effective in identifying the source of bleeding. Postoperative bleeding is a rare and frequently fatal complication of juvenile nasopharyngeal angiofibroma. As a complement to conventional autopsy, postmortem angiography is a valuable tool for the detection of lethal acute hemorrhagic foci, and establishing a routine procedure for PMCTA may improve its efficiency.

  6. Computerized industrial tomography

    International Nuclear Information System (INIS)

    Ashraf, M.M.

    1999-01-01

    Computerized Tomographic (CT) has been used for a number of applications in the field of medicine and industry. For the last couple of years, the technique has been applied for the material characterization and detection of defects and flaws inside the industrial components of nuclear, aerospace and missile industries. A CT scanner of first generation was developed at the institute. The scanner has been used to demonstrate couple of applications of CT in the field of non destructive testing of materials. The data acquired by placing the test objects at various angles and scanning the object through a source detector assembly has been processed on a Pentium computer for image reconstruction using a filtered back projection method. The technique has been developed which can be modified and improved to study various other applications in materials science and a modern computerized tomographic facility can be established. (author)

  7. Study on forefoot by computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Machida, Eiichi (Nihon Univ., Tokyo. School of Medicine)

    1983-10-01

    Computerized tomography (CT) was used to study coronary sections of the forefoot in both normal and abnormal human feet. CT images of the transverse arches at the metatarsal head, middle and base of the shaft were classified into five patterns. In the pattern most commonly found in normal feet, the second metatarsus appeared elevated above the other metatarsal bones at all points, and there was a gradual and even reduction in elevation from the second to the fifth metatarsal. In cases of hallux valgus, however, a variety of deformities were noted in the arc of the second to fifth metatarsals, particularly at the head. The rotation of the first metatarsus and shift of the sesamoids were measured from CT images at the head of the first metatarsus. In hallux valgus, both the rotation and the sesamoid shift appeared to have a wider angle than in the case of normal feet. In normal feet, the differences between the rotation of the first metatarsus and shift of the sesamoids were relatively small, whereas in hallux valgus there was a much greater degree of variation. Furthermore, while normal feet the variation in rotation of the first metatarsus and sesamoid shift both tended to be either great or small, in hallux valgus a large degree of sesamoid shift was sometimes found in combination with a small degree of rotation of the first metatarsus.

  8. Study on forefoot by computerized tomography

    International Nuclear Information System (INIS)

    Machida, Eiichi

    1983-01-01

    Computerized tomography (CT) was used to study coronary sections of the forefoot in both normal and abnormal human feet. CT images of the transverse arches at the metatarsal head, middle and base of the shaft were classified into five patterns. In the pattern most commonly found in normal feet, the second metatarsus appeared elevated above the other metatarsal bones at all points, and there was a gradual and even reduction in elevation from the second to the fifth metatarsal. In cases of hallux valgus, however, a variety of deformities were noted in the arc of the second to fifth metatarsals, particularly at the head. The rotation of the first metatarsus and shift of the sesamoids were measured from CT images at the head of the first metatarsus. In hallux valgus, both the rotation and the sesamoid shift appeared to have a wider angle than in the case of normal feet. In normal feet, the differences between the rotation of the first metatarsus and shift of the sesamoids were relatively small, whereas in hallux valgus there was a much greater degree of variation. Furthermore, while normal feet the variation in rotation of the first metatarsus and sesamoid shift both tended to be either great or small, in hallux valgus a large degree of sesamoid shift was sometimes found in combination with a small degree of rotatin of the first metatarsus. (author)

  9. First experience with a mobile computed tomograph in the USSR

    International Nuclear Information System (INIS)

    Portnoj, L.M.

    1989-01-01

    Utilization experience of mobile computerized tomograph mounted in the bus is presented. Problems concerning staff, selection of medical base institutes etc are considered. Efficiency of mobile computerized tomographes in revealing different diseases is pointed out

  10. Computed tomographic study of aged schizophrenic patients

    International Nuclear Information System (INIS)

    Seno, Haruo; Fujimoto, Akihiko; Ishino, Hiroshi; Shibata, Masahiro; Kuroda, Hiroyuki; Kanno, Hiroshi.

    1997-01-01

    The width of interhemispheric fissure, lateral ventricles and third ventricle were measured using cranial computed tomography (CT; linear method) in 45 elderly inpatients with chronic schizophrenia and in 28 age-matched control subjects. Twenty-three patients were men and 22 were women. In addition, Mini-Mental State Examination, Brief Psychiatric Rating Scale (BPRS) and a subclass of BPRS were undertaken in all patients. There is a significant enlargement of the maximum width of the interhemispheric fissure (in both male and female) and a significant enlargement of ventricular system (more severe in men than in women) in aged schizophrenics, as seen with CT, compared with normal controls. These findings are consistent with previous studies of non-aged schizophrenic patients. Based upon the relation between psychiatric symptoms and CT findings, the most striking is a significant negative correlation between the third ventricle enlargement and the positive and depressive symptoms in all patients. This result suggests that the advanced third ventricle enlargement may decrease these symptoms in aged schizophrenics. (author)

  11. Computed tomographic study on Mycoplasma pneumoniae pneumonia

    International Nuclear Information System (INIS)

    Tanaka, Hiroshi; Koba, Hiroyuki; Mori, Takuji; Mori, Masaki; Tsunematsu, Kazunori; Natori, Hiroshi; Asakawa, Mitsuo; Suzuki, Akira; Doi, Mikio.

    1985-01-01

    Serologically proven 21 patients with Mycoplasma pneumoniae pneumonia that showed infiltrative shadows on chest radiograms were studied by computed tomography (CT). Localization of the lesion and the fashion of its progression through the lung were analyzed. Following 3 loci were defined on the basis of the investigations of critical analysis of the chest radiograms, and of radiopathological analysis of the experimental animal model of mycoplasmal pneumonia with soft X-ray image. I: Peribronchial and periarterial interstitium. II: Bronchiole and its surroundings. III: Lung parenchyma, on hilar area as IIIh, on marginal area as IIIm. Even in the early phase of this disease, radiopathological findings on CT have been distributed in all loci mentioned above. The Shadow disappeared from locus III approximately 14th day from the onset. The shadow have remained, however, loci I, II for a long period. Those findings suggest that locus I and II are one of the major focus of Mycoplasma neumoniae pneumonia. Volume loss in the locus III was observed 78 % of the cases at 28th day from the onset. The shadow on locus IIIh was more prominent than locus IIIm. Reported analytical method with CT could be widely applied to disclose a radiopathological details in other infectious diseases of the lung. (author)

  12. A computed tomographic study on epilepsy

    International Nuclear Information System (INIS)

    Bae, Hoon Sik

    1980-01-01

    140 patients with epileptic seizure were studied by computed tomography during the period from Feb. 1979 to Aug. 1979 in the Department or Radiology, College of Medicine, Hangyang University. Those findings on CT and clinical records including EEG findings were reviewed. The results were as follows: 1. Age distribution of the total 140 patients was broad ranging from 1 month to 63 years. 73.5% of patients was below the age of 30. The patient population was comprised of 93 males and 47 females, and its male to female ratio was 2 : 1. 2. The type of epileptic seizure were classified according to the International League against Epilepsy. 42.9% of patients had primary generalized seizure, 47.1% with partial seizure, and 10% with non classifiable seizure. 3. As additional symptoms and signs except seizure, headache was most common, and the next was nausea and vomiting. Uncommonly, there were also insomnia, personality change, and memory disturbance. 4. 37.1% of patients had less than 1 month of seizure history, 19.3% between 1 year and 5 years. 5. EEG findings were available in 41 patients, and normal in 15 cases. 26 patients revealed abnormal findings. Among those abnormal findings focal slowing was appeared in 19.5% and generalized slowing in 17.1%. 6. 52% of patients showed abnormal findings on CT. The most common abnormal findings was focal low density (30%), and the next was diffuse hydrocephalus (7.1%). After contrast infusion, contrast enhancement was occurred in cases with focal low density, focal high or isodense mass density. In patients with focal low density, ring or nodular enhancement were common, and diffuse or serpentime enhancement in focal high or isodence mass density. 7. The frequency of structural abnormalities on CT was more common in patients below the age of 10 and over 30 than other age groups. The epilepsy starting below 10 and over 30 years of age showed structural abnormalities in 63.6-100%. 8. The patients who had less than 6 months of

  13. A computed tomographic study on epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Hoon Sik [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    1980-06-15

    140 patients with epileptic seizure were studied by computed tomography during the period from Feb. 1979 to Aug. 1979 in the Department or Radiology, College of Medicine, Hangyang University. Those findings on CT and clinical records including EEG findings were reviewed. The results were as follows: 1. Age distribution of the total 140 patients was broad ranging from 1 month to 63 years. 73.5% of patients was below the age of 30. The patient population was comprised of 93 males and 47 females, and its male to female ratio was 2 : 1. 2. The type of epileptic seizure were classified according to the International League against Epilepsy. 42.9% of patients had primary generalized seizure, 47.1% with partial seizure, and 10% with non classifiable seizure. 3. As additional symptoms and signs except seizure, headache was most common, and the next was nausea and vomiting. Uncommonly, there were also insomnia, personality change, and memory disturbance. 4. 37.1% of patients had less than 1 month of seizure history, 19.3% between 1 year and 5 years. 5. EEG findings were available in 41 patients, and normal in 15 cases. 26 patients revealed abnormal findings. Among those abnormal findings focal slowing was appeared in 19.5% and generalized slowing in 17.1%. 6. 52% of patients showed abnormal findings on CT. The most common abnormal findings was focal low density (30%), and the next was diffuse hydrocephalus (7.1%). After contrast infusion, contrast enhancement was occurred in cases with focal low density, focal high or isodense mass density. In patients with focal low density, ring or nodular enhancement were common, and diffuse or serpentime enhancement in focal high or isodence mass density. 7. The frequency of structural abnormalities on CT was more common in patients below the age of 10 and over 30 than other age groups. The epilepsy starting below 10 and over 30 years of age showed structural abnormalities in 63.6-100%. 8. The patients who had less than 6 months of

  14. Computed tomographic study of hormone-secreting microadenomas

    International Nuclear Information System (INIS)

    Hemminghytt, S.; Kalkhoff, R.K.; Daniels, D.L.; Williams, A.L.; Grogan, J.P.; Haughton, V.M.

    1983-01-01

    A review was made of the computed tomographic (CT) studies of 33 patients with hormone-secreting microadenomas that had been verified by transsphenoidal surgery and endocrinologic evaluation. In previous studies in small series of patients, the CT appearance of pituitary microadenomas has been reported as hypodense, isodense, and hyperdense. In this study, CT showed a region of diminished enhancement and ususally an enlarged pituitary gland in cases of prolactin-secreting adenomas. HGH- or ACTH-secreting adenomas were less consistently hypodense. It is concluded that hypodensity and enlargement in the pituitary gland are the most useful criteria for identification of microadenomas. Some technical factors that may affect the CT appearance of microadenomas and lead to conflicting reports are discussed

  15. Tomographic study of temporomandibular joints before orthodontic treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Ki Jeong [Kyung Hee Univ. College of Dentistry, Seoul (Korea, Republic of)

    2001-12-15

    To determine whether there is a relationship between abnormal temporomandibular joint radiographic findings and age or gender in a sample of preorthodontic patients. Individualized corrected sagittal tomographs of 188 temporomandibular joints in 94 preorthodontic patients, aged 11 to 29 years, were taken and viewed by an observer blinded to clinical records. The study population was divided into 2 aged groups (11-15 years and 16-29 years) for comparative purpose. Temporomandibular joint radiographic findings were classified as normal or abnormal. There was no difference in ratio of abnormal to normal findings between the both aged groups. The frequency of osseous abnormalities was similar with that of abnormalities of condylar position. Abnormalities in CP and JS were most frequent in all aged groups. There is no significant difference between ages or genders for temporomandibular joint radiographic abnormalities.

  16. Sequential Computerized Mastery Tests--Three Simulation Studies

    Science.gov (United States)

    Wiberg, Marie

    2006-01-01

    A simulation study of a sequential computerized mastery test is carried out with items modeled with the 3 parameter logistic item response theory model. The examinees' responses are either identically distributed, not identically distributed, or not identically distributed together with estimation errors in the item characteristics. The…

  17. Computerized spleen volumetry

    International Nuclear Information System (INIS)

    Jahnke, T.; Mohring, R.; Schertel, L.

    1981-01-01

    We examined in experimental studies and clinical investigations on 34 patients in how far volumetry of the spleen can be carried out with a commonly available program, a whole-body computerized tomograph (SOMATOM) and an analytic equipment (EVALUSKOP). In this connection the authors tried to find also other ways of spleen volumetry by means of this unit combination. Our final result was that the given program for the usage of labelled areas presents itself as the best-suited technique for spleen volumetry which is also applicable in practice. (orig./MG) [de

  18. Sensitivity study of poisson corruption in tomographic measurements for air-water flows

    International Nuclear Information System (INIS)

    Munshi, P.; Vaidya, M.S.

    1993-01-01

    An application of computerized tomography (CT) for measuring void fraction profiles in two-phase air-water flows was reported earlier. Those attempts involved some special radial methods for tomographic reconstruction and the popular convolution backprojection (CBP) method. The CBP method is capable of reconstructing void profiles for nonsymmetric flows also. In this paper, we investigate the effect of corrupted CT data for gamma-ray sources and aCBP algorithm. The corruption in such a case is due to the statistical (Poisson) nature of the source

  19. Quantitative analysis of normal thallium-201 tomographic studies

    International Nuclear Information System (INIS)

    Eisner, R.L.; Gober, A.; Cerqueira, M.

    1985-01-01

    To determine the normal (nl) distribution of Tl-201 uptake post exercise (EX) and at redistribution (RD) and nl washout, Tl-201 rotational tomographic (tomo) studies were performed in 40 subjects: 16 angiographic (angio) nls and 24 nl volunteers (12 from Emory and 12 from Yale). Oblique angle short axis slices were subjected to maximal count circumferential profile analysis. Data were displayed as a ''bullseye'' functional map with the apex at the center and base at the periphery. The bullseye was not uniform in all regions because of the variable effects of attenuation and resolution at different view angles. In all studies, the septum: lateral wall ratio was 1.0 in males and approximately equal to 1.0 in females. This occurred predominantly because of anterior defects due to breast soft tissue attenuation. EX and RD bullseyes were similar. Using a bi-exponential model for Tl kinetics, 4 hour normalized washout ranged 49-54% in each group and showed minimal variation between walls throughout the bullseye. Thus, there are well defined variations in Tl-201 uptake in the nl myocardium which must be taken into consideration when analyzing pt data. Because of these defects and the lack of adequate methods for attenuation correction, quantitative analysis of Tl-201 studies must include direct comparison with gender-matched nl data sets

  20. Computerized Adaptive Testing. A Case Study.

    Science.gov (United States)

    1980-12-01

    Vocational Interest Blank in 1927 [Dubois 1970]. 3. German Contributions Cattell also studied for a period of three years in Leipzig under Wilhelm Wundt in the...world’s first psychological laboratory, 2 founded by Wundt in 1879 [Heidbreder 1933]. 2William James’ laboratory, established at Harvard in 1875, did...have become important parts of psychological test theory. Under Wundt , Spearman’s principal endeavor was experimental psychology, but he also found time

  1. [Computerized study of perioperative difficulties of stapedectomy].

    Science.gov (United States)

    Cadavid Zink, R; Ballivian, H; Gamboa, F J; Olaizola, F

    1993-01-01

    A retrospective study of 1035 stapedectomies was performed to assess the incidence of intraoperative complications between 1972-1990. We found 45.89% of complications. We divided this alterations in 6 groups: 1) hemorrhage (20.67%), 2) stapes, foot plate, oval window (8.40%), 3) alterations in the middle ear (6.85%), 4) alterations in the incus (3.76%), 5) alterations in the external ear canal (3.57%) and 6) problems with protesis or graf (2.60%). We have analyzed these complications. We propose to carry out the solutions.

  2. Computerized tomography studies on schizophrenic diseases

    International Nuclear Information System (INIS)

    Gross, G.; Huber, G.; Schuettler, R.

    1982-01-01

    Earlier clinical pneumoencephalographic studies showed a subgroup of schizophrenics that have small and dysplastic cerebral ventricles as well as a subgroup with a 'pure defect', i.e., a slight internal brain atrophy. In echoencephalograms of pure and mixed residual schizophrenic syndrome patients, a significantly higher average transverse diameter of the third ventricle was demonstrated compared to that in patients with complete remissions. Correlations cannot be expected between certain groups of disease, e.g., epilepsy, multiple sclerosis, or schizophrenia on the whole, and pneumoencephalographic (PEG) and CT findings. Only schizophrenics with distinct signs of pure defect that had persisted for at least 3 years revealed deviations from normal by CT and PEG, but those with irreversible fixed deformations of personality structure did not. In patients who were 50 years of age or less with psychic reactive and psychopathic personality disorders, CT showed an average third ventricle diameter of 4.2 mm (range 2-6 mm). Of 117 schizophrenics (average age 35.5 years), only 28% revealed pathological CT changes. However, of 36 schizophrenics with pure residual syndromes 69% showed pathological CT findings that always concerned the third ventricle, rarely the lateral ventricles, and in no case the cortex. The average transverse diameter of the third ventricle in this subgroup with pure defect was 7.6 mm, as compared to 4.6 mm in the subgroup of schizophrenics with complete remission. There was no increase in size with increasing years until the 50th year in schizophrenics, as well as in the control group of variations of psychic being (neuroses and psychopathic personality disorders). (orig./MG)

  3. Computerized tomography studies on schizophrenic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Gross, G.; Huber, G.; Schuettler, R.

    1982-01-01

    Earlier clinical pneumoencephalographic studies showed a subgroup of schizophrenics that have small and dysplastic cerebral ventricles as well as a subgroup with a 'pure defect', i.e., a slight internal brain atrophy. In echoencephalograms of pure and mixed residual schizophrenic syndrome patients, a significantly higher average transverse diameter of the third ventricle was demonstrated compared to that in patients with complete remissions. Correlations cannot be expected between certain groups of disease, e.g., epilepsy, multiple sclerosis, or schizophrenia on the whole, and pneumoencephalographic (PEG) and CT findings. Only schizophrenics with distinct signs of pure defect that had persisted for at least 3 years revealed deviations from normal by CT and PEG, but those with irreversible fixed deformations of personality structure did not. In patients who were 50 years of age or less with psychic reactive and psychopathic personality disorders, CT showed an average third ventricle diameter of 4.2 mm (range 2-6 mm). Of 117 schizophrenics (average age 35.5 years), only 28% revealed pathological CT changes. However, of 36 schizophrenics with pure residual syndromes 69% showed pathological CT findings that always concerned the third ventricle, rarely the lateral ventricles, and in no case the cortex. The average transverse diameter of the third ventricle in this subgroup with pure defect was 7.6 mm, as compared to 4.6 mm in the subgroup of schizophrenics with complete remission. There was no increase in size with increasing years until the 50th year in schizophrenics, as well as in the control group of variations of psychic being (neuroses and psychopathic personality disorders).

  4. Computerized tomography

    International Nuclear Information System (INIS)

    1980-01-01

    Improvements in the design of computerized tomographic X-ray equipment are described which lead to improvements in the mechanical properties, speed and size of scanning areas. The method envisages the body being scanned as a two-dimensional matrix of elements arising from a plurality of concentric rings. The concentric centre need not coincide with the axis of rotation. The procedures for rotation of the X-ray beam and detectors around the patient and for translating the measured information into attenuation coefficients for each matrix element of the body are described in detail. Explicit derivations are given for the mathematical formulae used. (U.K.)

  5. A tomographic study of the condyle position in temporomandibular disorders

    International Nuclear Information System (INIS)

    Choi, Sung Youn; Ryu, Young Kyu

    1988-01-01

    The aim of this study was to determine whether T.M.J. tomographic examination yielded significant difference in condyle positions among asymptomatic, myalgia, derangement, and arthrosis group of T.M.J. disorders. The author obtained sagittal linear tomograms of right and left T.M.Js. of 36 asymptomatic, 22 myalgia, 54 derangement, and 31 arthrosis patients taken at serial lateral, central, and medial sections in the intercuspal position after submentovertex radiographs analyzed. With the dual linear measurements of the posterior and anterior interarticular space, condyle positions were mathematically expressed as proportion. All data from these analysis was recorded and processed statistically. The results were obtained as follows: 1. In asymptomatic group, radiographically concentric condyle position was found in 50.0% to 65.4% of subjects, with a substance range of variability. No significant differences existed between men and women and also between right and left T.M.Js. for condyle position. 2. In women, significant difference for mean condyle position of left lateral section of each diagnostic category existed between derangement and myalgia groups (P< .05). Also that of left central section existed between derangement and myalgia group, and that of left medial section existed between derangement and myalgia groups (P< . 05). 3. In main-symptom side, condyle position in myalgia group was more concentric, and condyle position in derangement and group was more posterior. This showed significant differences between derangement and myalgia groups in lateral, central, and medial sections of main symptom side, and only between derangement and myalgia groups in central section of contra-lateral sides (P< .05). Condyle position in arthrosis group was broadly distributed among all positions. 4. In contra-lateral side, significant difference for mean condyle position of central section of each symptomatic group existed between derangement and myalgia group (P< .05

  6. A tomographic study of the condyle position in temporomandibular disorders

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sung Youn; Ryu, Young Kyu [Dept. of Oral Radiology, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    1988-11-15

    The aim of this study was to determine whether T.M.J. tomographic examination yielded significant difference in condyle positions among asymptomatic, myalgia, derangement, and arthrosis group of T.M.J. disorders. The author obtained sagittal linear tomograms of right and left T.M.Js. of 36 asymptomatic, 22 myalgia, 54 derangement, and 31 arthrosis patients taken at serial lateral, central, and medial sections in the intercuspal position after submentovertex radiographs analyzed. With the dual linear measurements of the posterior and anterior interarticular space, condyle positions were mathematically expressed as proportion. All data from these analysis was recorded and processed statistically. The results were obtained as follows: 1. In asymptomatic group, radiographically concentric condyle position was found in 50.0% to 65.4% of subjects, with a substance range of variability. No significant differences existed between men and women and also between right and left T.M.Js. for condyle position. 2. In women, significant difference for mean condyle position of left lateral section of each diagnostic category existed between derangement and myalgia groups (P< .05). Also that of left central section existed between derangement and myalgia group, and that of left medial section existed between derangement and myalgia groups (P< . 05). 3. In main-symptom side, condyle position in myalgia group was more concentric, and condyle position in derangement and group was more posterior. This showed significant differences between derangement and myalgia groups in lateral, central, and medial sections of main symptom side, and only between derangement and myalgia groups in central section of contra-lateral sides (P< .05). Condyle position in arthrosis group was broadly distributed among all positions. 4. In contra-lateral side, significant difference for mean condyle position of central section of each symptomatic group existed between derangement and myalgia group (P< .05

  7. Coupling two iteratives algorithms for density measurements by computerized tomography

    International Nuclear Information System (INIS)

    Silva, L.E.M.C.; Santos, C.A.C.; Borges, J.C.; Frenkel, A.D.B.; Rocha, G.M.

    1986-01-01

    This work develops a study for coupling two iteratives algotithms for density measurements by computerized tomography. Tomographies have been obtained with an automatized prototype, controled by a microcomputer, projected and assembled in the Nuclear Instrumentation Laboratory, at COPPE/UFRJ. Results show a good performance of the tomographic system, and demonstrate the validity of the method of calculus adopted. (Author) [pt

  8. Computerized tools in psychology: cross cultural and genetically informative studies of memory

    Directory of Open Access Journals (Sweden)

    Ismatullina V.

    2016-01-01

    Full Text Available In this article we presented the computerized tools for psychological studies of memory. The importance of implementing computerized automated tools for psychological studies is discussed. It has been shown that this tools can be used both for cross-cultural and genetically informative studies. The validity of these tools for cross-cultural and genetically informative studies of memory can be seen as the first step to use automated computerized tools for big data collection in psychology.

  9. Midline oligodendrogliomas as studied by means of computed tomographic, angiographic, and positron-emission tomographic evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Kenji; Kowada, Masayoshi; Sakamoto, Tetsuya; Mineura, Katsuyoshi (Akita Univ. (Japan). Hospital)

    1989-08-01

    Five patients with intraventricular oligodendroglioma involving the lateral ventricle were reviewed by computed tomography (CT), cerebral angiography, and positron-emission tomography (PET) to delineate specific neuroradiological features of the tumors in comparison to those involving the cerebral hemispheres. Intraventricular mass lesions, extending largely from the anterior horn to the body or trigone of the lateral ventricle, were seen as hyperdense tumors in on CT; none was iso- or hypodense. Asymmetrical dilation of the lateral ventricles was noted. Noteworthy was the fact that all of the lesions demonstrated a homogeneous contrast enhancement. Calcification or hypodense areas within the tumor matrix suggestive of cyst formation were found in 4 cases. No peritumoral edema was demonstrated. On angiograms, in all cases the tumors were visualized as hypervascular, space occupying mass lesions supplied by such feeding arteries as anterior and posterior choroidal, lenticulo-striate, thalamo-perforating, and pericallosal arteries. Among these arteries, either medial or lateral posterior choroidal arteries, or both, were commonly seen in these vascular tumors. Fine tumor vessels were also seen in the distal portion of these arteries. They were accompanied by a homogeneous tumor stain at either the late-arterial, capillary, or early-venous phase. PET images from a 21 year old female showed that the intraventricular tumor had an increased cerebral blood flow and volume at the tumor site, indicating a hypervascular tumor. However, this tumor was considered less malignant on the basis of its decreased rate of glycolysis, as evaluated by PET studies with 18-F-deoxyglucose. Lateral ventricular oligodendrogliomas, synonymously termed 'midline oligodendrogliomas,' have fairly specific neuroradiological features different from those of hemispheric oligodendrogliomas.

  10. Computed tomographic study of 50 patients with hypodense hepatic injuries in childhood

    International Nuclear Information System (INIS)

    Pereira, Ines Minniti Rodrigues; Alvares, Beatriz Regina; Baracat, Jamal; Martins, Daniel Lahan; Pereira, Ricardo Minniti Rodrigues

    2006-01-01

    Objective: To describe the different tomographic findings in hypodense hepatic lesions in children and its differential diagnosis. Materials and methods: computed tomographic studies were obtained from 50 patients (age range: 0-16 years) with low-density liver lesions previously diagnosed by ultrasound. Images were made before and after administration of intravenous contrast medium. Image findings were analyzed and afterwards correlated with anatomopathological diagnosis. Results: forty-seven of 50 cases were confirmed, 30 by anatomopathological diagnosis. Most of then were benign lesions, hemangioma in 20%. Such lesions presented a homogeneous contrast absorption, mainly at the delayed phase, differing from malignant lesions. Metastasis was the most frequently found malignant lesion (18%). Conclusion: computed tomographic study is of great value in complementing the diagnosis of hypodense hepatic lesions in children, and must follow ultrasound diagnosis as a routine procedure. (author)

  11. Computerized dosimetric system for studying radiation fields of afterloading apparatus

    International Nuclear Information System (INIS)

    Andryushin, O.S.; Gorshkov, M.I.

    1988-01-01

    Works on designing a computerized dosimetric scanner (CODOS) for studying radiation fields of remote therapeutic apparatus, providing dosimetric data input from semiconductor transducers and ionization chambers directly into the computer memory were carried out. The basic problems were to provide reproducibility and accuracy of the initial dosimetric data, formation of the data bank on LUEhV-15M1 accelerator bremsstrahlung and electron radiation fields. An extra problem was to provide isodose curves for manual scheduling of radiotherapy. The 15 VUMS-28-025 complex based on Elektronika-60 computer was chosen as a host computer, photodiodes were used as a semiconductor detector, the 70108 rod chamber and VA-J-18 dosemeters were used as an ionization chamber. The results of studies with the CODOS system have been shown that it meets the dosimetric requirements for therapeutic apparatus

  12. Study on a computerized compact simulator of NHR-200

    International Nuclear Information System (INIS)

    Gao Zuying; Dong Yujie

    1997-01-01

    A fully computerized compact simulator is studied in accordance with the engineering practical need of NHR-200. A SUN SPARC 2 stand-alone workstation is selected as its computer system and multi-task structure of software is employed. Simulation program is derived from the RETRAN-02 code. The standard I/O devices are used as its interface equipment and the man-machine interface graphic program is coded on the basis of X Window System. Shared memory and semaphores are used for inter-task communication and a timer is used in real-time control of tasks. Its accuracy and simulation speed are verified by using several typical accident transients. The accuracy and speed are perfectly able to meet the requirements of engineering simulation. It is useful for normal and accident transient analysis, engineering study and design, reactor operation support and personnel training

  13. Computer tomographic and angiographic studies of histologically confirmed intrahepatic masses

    International Nuclear Information System (INIS)

    Janson, R.; Lackner, K.; Paquet, K.J.; Thelen, M.; Thurn, P.

    1980-01-01

    The computer tomographic and angiographic findings in 53 patients with intrahepatic masses were compared. The histological findings show that 17 were due to echinococcus, 12 were due to hepatic carcinoma, ten were metastases, five patients had focal nodular hyperplasia, three an alveolar echinococcus and there were three cases with an haemangioma of the liver and a further three liver abscesses. Computer tomography proved superior in peripherally situated lesions, and in those in the left lobe of the liver. Arteriography was better at demonstrating lesions below 2 cm in size, particularly vascular tumours. As a pre-operative measure, angiography is to be preferred since it is able to demonstrate anatomic anomalies and variations in the blood supply, as well as invasion of the portal vein or of the inferior vena cava. (orig.) [de

  14. Computer tomographic and angiographic studies of histologically confirmed intrahepatic masses

    Energy Technology Data Exchange (ETDEWEB)

    Janson, R.; Lackner, K.; Paquet, K.J.; Thelen, M.; Thurn, P.

    1980-06-01

    The computer tomographic and angiographic findings in 53 patients with intrahepatic masses were compared. The histological findings show that 17 were due to echinococcus, 12 were due to hepatic carcinoma, ten were metastases, five patients had focal nodular hyperplasia, three an alveolar echinococcus and there were three cases with an haemangioma of the liver and a further three liver abscesses. Computer tomography proved superior in peripherally situated lesions, and in those in the left lobe of the liver. Arteriography was better at demonstrating lesions below 2 cm in size, particularly vascular tumours. As a pre-operative measure, angiography is to be preferred since it is able to demonstrate anatomic anomalies and variations in the blood supply, as well as invasion of the portal vein or of the inferior vena cava.

  15. Computerized tomographic study on the brain of patients with alcohol dependence

    International Nuclear Information System (INIS)

    Kato, Akira; Tsuji, Motohiro; Nakamura, Michihiko; Nakajima, Teruo.

    1991-01-01

    One hundred ten patients with alcohol dependence and 56 psychiatric patients with either senile dementia, amphetamine psychosis, epilepsy or chronic schizophrenia were investigated with a CT scan of the brain. The maximum width of the 3rd ventricle was measured, and the presence/absence of enlargement of the lateral ventricle and of atrophy of the frontal lobe was determined independently by 3 physicians. The width of the 3rd ventricle in alcoholic and the other patients examined was gradually enlarged with aging, and the width in these patients was significantly larger than that in the age-matched control patients who were selected from the patients with amphetamine psychosis, epilepsy or schizophrenia. The enlargement of the lateral ventricles observed in the alcoholic patients always accompanied the enlargement of the 3rd ventricle, but not vice versa. The alcoholic patients with frontal lobe atrophy showed a higher incidence of withdrawal delirium than the patients without atrophy. These findings suggest that the chronic intake of alcohol might affect primarily the area around the 3rd ventricle, resulting in enlargement of this ventricle and consequential enlargement of the lateral ventricles and also that the alcoholic patients with frontal lobe atrophy could have a high risk for a manifestation of alcoholic withdrawal delirium. (author)

  16. Study of Pelvicaliceal Anatomy by Helical Computerized Tomography

    International Nuclear Information System (INIS)

    Al-Qahtani, Fahd N.; Ali, Gaber A.; Kamal, Baher A.; Taha, Saud A.

    2003-01-01

    To evaluate the role of 3-dimensional images produced by computerized tomography (CT), using intravenous contrast, to study pelvicaliceal anatomy.This might be of help in endourological procedure. The study was conducted in the King Fahd Hospital of the University, King Faisal University. Dammam,Kingdom of Saudi Arabia. The study took place from July 2002 through to October 2002 .Helical CT was carried for patients who were investigated using excretory urography for any reason. A CT was carried out to the kidneys only within 10 minutes ( between 5 and 15 minute films of excretory urography).Images were reprocessed by 3-dimension construction after subtracting all structures except for the palvicaliceal system. Thity-six normal kidneys were studied. The upper pole was drained by a single caliceal infundibulum in all 36(100%) kidneys.the middle segement of the kidney was drained by 2 infundibula in 32 (89%) kidneys. Four (11%) kidneys have no middle caliceal infudibula. The lower pole was drained by 2 caliceal infundibula in 23 (64%) and a single infundibulum in 13 (36%) kidneys. The minor calices draining each renal segment were seen clearly. Three-dimensional images derived by helical CT are feasible for evaluating the anatomy of palvicaliceal system,and, can be of help in endourological procedures. (author)/

  17. Computerized study with 201Tl of the gold thyroid node

    International Nuclear Information System (INIS)

    Palermo, F.; Saitta, B.; Coghetto, F.; Tiberio, M.; Caldato, L.

    1982-01-01

    Because of its physical and potassium-metabolic characteristics 201 Tl is more suitable than 131 Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behaviour for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 μCi/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential 201 Tl uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different 201 Tl kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular dissappearance-index. (orig.) [de

  18. Computerized adaptive measurement of depression: A simulation study

    Directory of Open Access Journals (Sweden)

    Mammen Oommen

    2004-05-01

    Full Text Available Abstract Background Efficient, accurate instruments for measuring depression are increasingly important in clinical practice. We developed a computerized adaptive version of the Beck Depression Inventory (BDI. We examined its efficiency and its usefulness in identifying Major Depressive Episodes (MDE and in measuring depression severity. Methods Subjects were 744 participants in research studies in which each subject completed both the BDI and the SCID. In addition, 285 patients completed the Hamilton Depression Rating Scale. Results The adaptive BDI had an AUC as an indicator of a SCID diagnosis of MDE of 88%, equivalent to the full BDI. The adaptive BDI asked fewer questions than the full BDI (5.6 versus 21 items. The adaptive latent depression score correlated r = .92 with the BDI total score and the latent depression score correlated more highly with the Hamilton (r = .74 than the BDI total score did (r = .70. Conclusions Adaptive testing for depression may provide greatly increased efficiency without loss of accuracy in identifying MDE or in measuring depression severity.

  19. Anatomic radiological study of transverse diameter of abdominal aorta by computerized tomography

    International Nuclear Information System (INIS)

    Ures, S.

    1984-01-01

    The transverse diameter of abdominal aorta by computerized tomography is studied. The purpose is establish the frequent standard diameters and then diagnose early pathologies, mainly aneurisms. (M.A.C.) [pt

  20. Suprathermal electron studies in the TCV tokamak: Design of a tomographic hard-x-ray spectrometer

    International Nuclear Information System (INIS)

    Gnesin, S.; Coda, S.; Decker, J.; Peysson, Y.

    2008-01-01

    Electron cyclotron resonance heating and electron cyclotron current drive, disruptive events, and sawtooth activity are all known to produce suprathermal electrons in fusion devices, motivating increasingly detailed studies of the generation and dynamics of this suprathermal population. Measurements have been performed in the past years in the tokamak a configuration variable (TCV) tokamak using a single pinhole hard-x-ray (HXR) camera and electron-cyclotron-emission radiometers, leading, in particular, to the identification of the crucial role of spatial transport in the physics of ECCD. The observation of a poloidal asymmetry in the emitted suprathermal bremsstrahlung radiation motivates the design of a proposed new tomographic HXR spectrometer reported in this paper. The design, which is based on a compact modified Soller collimator concept, is being aided by simulations of tomographic reconstruction. Quantitative criteria have been developed to optimize the design for the greatly variable shapes and positions of TCV plasmas.

  1. Evaluation of paranasal sinus mucosa in coal worker's pneumoconiosis - A computed tomographic study

    Energy Technology Data Exchange (ETDEWEB)

    Ozdemir, H.; Altin, R.; Mahmutyazicioglu, K.; Kart, L.; Uzun, L.; Savranlar, A.; Davcanci, H.; Gundogdu, S. [Zonguldak Karaelmas University, Zonguldak (Turkey). School of Medicine

    2004-09-01

    Objective: To evaluate by computed tomographic scanning the paranasal mucosal changes of coal workers with and without pneumoconiosis. Methods: Examination of images and scores from paranasal computed tomographic scans. The study participants were 26 coal workers with pneumoconiosis, 29 coal workers without pneumoconiosis, and 20 controls. All were men. The extent and patterns of inflamatory paranasal sinus disease were evaluated on computed, tomographic scans by 2 radiologists using the terminology and definitions of Newman and associates. Results: Interobserver agreement for the presence of abnormalities was from good to excellent (K, 0.63-0.89). The mucosal scores of individuals and groups were higher for coal workers than for control subjects. Both scores were significantly higher in the pneumoconiosis group than in the 2 other groups. Conclusions: This study shows that paranasal sinuses were affected more severely in coal workers than in control subjects. In coal workers with pneumoconiosis, the affection was most severe. The relationship between coal dust exposure and paranasal mucosal changes needs further study.

  2. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  3. An ergonomics study of computerized emergency operating procedures: Presentation style, task complexity, and training level

    International Nuclear Information System (INIS)

    Xu Song; Song Fei; Li Zhizhong; Zhao Qianyi; Luo Wei; He Xuhong; Salvendy, Gavriel

    2008-01-01

    Emergency operating procedures (EOPs) are widely used in nuclear power plants (NPPs). With the development of information technology, computerized EOPs are taking the place of paper-based ones. Unlike paper-based EOPs, the industrial practice of computerized EOPs is still quite limited. Ergonomics issues of computerized EOPs have not been studied adequately. This study focuses on the effects of EOP presentation style, task complexity, and training level on the performance of the operators in the execution of computerized EOPs. One simulated computerized EOP system was developed to present two EOPs, each with different task complexity levels, by two presentation styles (Style A: one- and two-dimensional flowcharts combination; Style B: two-dimensional flowchart and success logic tree combination). Forty subjects participated in the experiment of EOP execution using the simulated system. Statistical analysis of the experimental results indicates that: (1) complexity, presentation style, and training level all can significantly influence the error rate. High-complexity tasks and lack of sufficient training may lead to a higher error rate. Style B caused a significantly higher error rate than style A did in the skilled phase. So the designers of computerized procedures should take the presentation styles of EOPs into account. (2) Task complexity and training level can significantly influence operation time. No significant difference was found in operation time between the two presentation styles. (3) Training level can also significantly influence the subjective workload of EOPs operations. This implies that adequate training is very important for the performance of computerized EOPs even if emergency responses with computerized EOPs are much more simple and easy than that with paper-based EOPs

  4. An ergonomics study of computerized emergency operating procedures: Presentation style, task complexity, and training level

    Energy Technology Data Exchange (ETDEWEB)

    Xu Song; Song Fei [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); Li Zhizhong [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)], E-mail: zzli@tsinghua.edu.cn; Zhao Qianyi; Luo Wei [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); He Xuhong [Scanpower Risk Management China Inc., Towercrest International Plaza, No. 3 Maizidian West Road, Chaoyang District, Beijing 100016 (China); Salvendy, Gavriel [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)

    2008-10-15

    Emergency operating procedures (EOPs) are widely used in nuclear power plants (NPPs). With the development of information technology, computerized EOPs are taking the place of paper-based ones. Unlike paper-based EOPs, the industrial practice of computerized EOPs is still quite limited. Ergonomics issues of computerized EOPs have not been studied adequately. This study focuses on the effects of EOP presentation style, task complexity, and training level on the performance of the operators in the execution of computerized EOPs. One simulated computerized EOP system was developed to present two EOPs, each with different task complexity levels, by two presentation styles (Style A: one- and two-dimensional flowcharts combination; Style B: two-dimensional flowchart and success logic tree combination). Forty subjects participated in the experiment of EOP execution using the simulated system. Statistical analysis of the experimental results indicates that: (1) complexity, presentation style, and training level all can significantly influence the error rate. High-complexity tasks and lack of sufficient training may lead to a higher error rate. Style B caused a significantly higher error rate than style A did in the skilled phase. So the designers of computerized procedures should take the presentation styles of EOPs into account. (2) Task complexity and training level can significantly influence operation time. No significant difference was found in operation time between the two presentation styles. (3) Training level can also significantly influence the subjective workload of EOPs operations. This implies that adequate training is very important for the performance of computerized EOPs even if emergency responses with computerized EOPs are much more simple and easy than that with paper-based EOPs.

  5. Effect of object functions on tomographic reconstruction a numerical study

    International Nuclear Information System (INIS)

    Babu Rao, C.; Baldev Raj; Ravichandran, V.S.; Munshi, P.

    1996-01-01

    Convolution back projection is the most widely used algorithm of computed tomography (CT). Theoretical studies show that under ideal conditions, the error in the reconstruction can be correlated with the second fourier space derivative of filter function and with the Laplacian of the object function. This paper looks into the second aspect of the error function. In this paper a systematic numerical study is presented on the effect to object functions on global and local errors. (author)

  6. A computed tomographic prolective trohoc study of chronic schizophrenics

    International Nuclear Information System (INIS)

    Glueck, E.; Radue, E.W.; Mundt, C.; Gerhardt, P.

    1980-01-01

    The maximal width of the third ventricle, the maximal distance between the outer tips of the anterior horns, and the number of enlarged cerebral sulci on the two highest CT slices were measured in 68 chronic schizophrenic patients on cranial computed tomograms in order to detect a possible enlargement of the cerebrospinal fluid (CSF) filled intracranial spaces. These results were compared with values obtained from a control group which was formed in accordance with definite exclusion criteria and matched-pair parameters (sex, age and maximal inner diameter of the skull). In a prolective trohoc study no difference was found in the size of the CSF spaces of schizophrenics and the controls. The psychopathological condition of the patients, which was classified in a semistandardized dialogue, also showed no correlation with the ventricular size or the number of enlarged cerebral sulci. (orig.)

  7. Computed tomographic study of the complication of head injury

    International Nuclear Information System (INIS)

    Kojima, Tadashi; Waga, Shiro

    1982-01-01

    Computed tomography (CT) is quite effective in the diagnosis of traumatic intracranial hemorrhage and cerebral contusion. Two hundred and nine consecutive patients with head injury were admitted to the hospital and studied by CT in the year from 1977 to 1980. Fourty-sevenof 209 patients had the complications of head injury, including 6 patients with carotidcavernous fistula (CCF), 6 with traumatic aneurysm, 10 with pneumocephalus, 4 with intracranial foreign body, 15 with optic nerve injury, and 14 with other cranial nerve palsy. Five patients with CCF had abnormal finding on CT. Two traumatic aneurysms of the superficial temporal artery were visualized on CT after injection of contrast material, but all traumatic aneurysms of the carotid siphon were not seven on CT. CT in all 10 patients with pneumocephalus and in all 4 patients with intracranial foreign body was of diagnostic value: On CT in two patients even small air bubbles were seen in details. In the CT examination of 29 patients who presented with cranial nerve injury, we could not find out any abnormality on CT. We emphasize that CT is much less effective in the diagnosis of vascular complication of head injury and traumatic cranial nerve injury. (author)

  8. Computer tomographic examinations in epilepsy

    International Nuclear Information System (INIS)

    De Villiers, J.F.K.

    1984-01-01

    Epileptic patients that was examined at the Universitas Hospital (Bloemfontein) by means of computerized tomography for the period July 1978 - December 1980, are divided into two groups: a) Patients with general epilepsy of convulsions - 507; b) Patients with vocal or partial epilepsy - 111. The method of examination and the results for both general and vocal epilepsy are discussed. A degenerative state was found in 35% of the positive computer tomographic examinations in general epilepsy and 22% of the positive examinations for vocal epilepsy. The purpose of the article was to explain the circumstances that can be expected when a epileptic patient is examined by means of computerized tomography

  9. Clinical study on primary epilepsy by computerized analysis of CT

    International Nuclear Information System (INIS)

    Tominaga, Hidefumi; Ueyama, Kenichi; Mizutani, Hiroshi; Imamura, Keisuke; Yoshidome, Kazushi; Matsumoto, Kei

    1985-01-01

    CT scans were examined by conventional linear measurement method and computerized analysis in 17 patients with primary epilepsy (Group A). Results were compared with those in healthy volunteers (Group B). Relationship between CT and EEG findings was also examined. The maximum width of the third cerebral ventricle (TCV) was narrowed in Group A than in Group B, with statistically significant difference. Low density rates (LDR) in Group A tended to be lower than those in Group B. There was significant difference in narrowed maximum width of TCV between Group A presenting with sudden dysrhythmia and Group B. For this type of Group A, LDR was significantly lower than that for Group B. These results suggest some changes in the brain in young epilepsy patients, especially those presenting with sudden dysrhythemia. (Namekawa, K.)

  10. Feasibility study for a computerized emergency preparedness simulation facility

    International Nuclear Information System (INIS)

    Gerhardstein, L.H.; Schroeder, J.O.; Sandusky, W.F.

    1979-11-01

    This report details the feasibility of a computerized Emergency Preparedness Simulation Facility (EPSF) for use by the Nuclear Regulatory Commission (NRC). The proposed facility would be designed to provide the NRC and other federal, state, and local government agencies with a capability to formulate, test, and evaluate the Emergency Preparedness Plans (EPP) which local and state agencies have/will establish for use during nuclear emergencies. In cases of any state emergency (including a nuclear emergency), high level state government officials will direct emergency procedures and insure that state and local emergency teams carry out tasks which have been established in their EPP. When an emergency exists, rapid mobilization of emergency teams, efficient communication, and effective coordination of individual team efforts is essential to safety, preservation of property, and overall public welfare. Current EPP evaluation procedures are qualitative in nature and while they do compare emergency drill performance with the EPP, the nature of the drills often does not provide enough realism to actual emergency conditions. Automated simulation of real emergency conditions using modern computer equipment and programming techniques will provide the NRC emergency evaluation teams a simulated environment which closely approximates conditions which would actually exist during a real emergency. In addition, the computer can be used to collect and log performance and event data which will aid the evaluation team in making assessments of the state or local area's EPP and their Emergency Preparedness Teams performance during emergency drills. Overall, a computerized EPSF can improve drill testing and evaluation efficiency, provide approximate emergency condition realism, and improve public awareness of local emergency procedures

  11. Computerized test versus personal interview as admission methods for graduate nursing studies: A retrospective cohort study.

    Science.gov (United States)

    Hazut, Koren; Romem, Pnina; Malkin, Smadar; Livshiz-Riven, Ilana

    2016-12-01

    The purpose of this study was to compare the predictive validity, economic efficiency, and faculty staff satisfaction of a computerized test versus a personal interview as admission methods for graduate nursing studies. A mixed method study was designed, including cross-sectional and retrospective cohorts, interviews, and cost analysis. One hundred and thirty-four students in the Master of Nursing program participated. The success of students in required core courses was similar in both admission method groups. The personal interview method was found to be a significant predictor of success, with cognitive variables the only significant contributors to the model. Higher satisfaction levels were reported with the computerized test compared with the personal interview method. The cost of the personal interview method, in annual hourly work, was 2.28 times higher than the computerized test. These findings may promote discussion regarding the cost benefit of the personal interview as an admission method for advanced academic studies in healthcare professions. © 2016 John Wiley & Sons Australia, Ltd.

  12. Regional cerebral blood flow during rest and skilled hand movements by xenon-133 inhalation and emission computerized tomography

    DEFF Research Database (Denmark)

    Lauritzen, M; Henriksen, L; Lassen, N A

    1981-01-01

    Regional cerebral blood flow (CBF) was studied in 16 normal adult volunteers during rest and in 10 the study was repeated during skilled hand movements. A fast-rotating ("dynamic"), single-photon emission computerized tomograph (ECT) with four detector heads was used. Xenon-133 was inhaled over a 1...... motor area on both sides by 34 +/- 15% (p less than 0.025)....

  13. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  14. A study of the decoding of multiple pinhole coded aperture RI tomographic images

    International Nuclear Information System (INIS)

    Hasegawa, Takeo; Kobayashi, Akitoshi; Nishiyama, Yutaka

    1980-01-01

    The authors constructed a Multiple Pinhole Coded Aperture (MPCA) and developed related decoding software. When simple coordinate transformation was performed, omission of points and shifting of counts occurred. By selecting various tomographic planes and collecting count for each tomographic depth from the shadowgram, a solution to these problems was found. The counts from the central portion of the tomographic image from the MPCA were incorrectly high, this was rectified by a correction function to improve the uniformity correction program of the γ-camera. Depth resolution of the tomographic image improved in proportion to the area encompassed by the pinhole configuration. An MPCA with a uniform arrangement of pinholes (e, g, pinholes in an arrangement parallel to the X-axis or the Y-axis) yielded decoded tomographic images of inferior quality. Optimum results were obtained with a ring-shaped arrangement yielding clinically applicable tomographic images even for large objects. (author)

  15. Tomographic findings of gastric gastrointestinal stromal tumor: a 14-case study

    International Nuclear Information System (INIS)

    Pelandre, Gustavo Lemos; Djahjah, Maria Celia; Nobre, Luiz Felipe; Gasparetto, Emerson Leandro; Marchiori, Edson; Pereira, Bruno Vilhena; Valadao, Marcus; Linhares, Eduardo

    2008-01-01

    Objective: The purpose of this study was to describe the tomographic findings of gastric gastrointestinal stromal tumor. Materials and methods: Fourteen patients with histopathologically and immunohistochemically confirmed gastric gastrointestinal stromal tumors, who had already been submitted to computed tomography scans before the treatment, were evaluated in the period between January 1999 and December 2006. The following tomographic variables were analyzed: lesion topography, size/dimensions, homogeneity, contour, margins, morphology, pattern and intravenous contrast-enhancement intensity, growth pattern, invasion of adjacent organs, presence of ulceration, fistula, calcifications, mesenteric fat infiltration, lymphadenomegaly and presence of distant metastasis. Results: Tumors were found in the body (57.1%) or in the gastric fundus (42.9%), with sizes ranging between 6.0 cm and 23.0 cm (mean, 11.5 cm). Predominantly extra luminal growth was observed in 57.1% of cases and intra/extra luminal in 35.7%. Subtle contrast-enhancement was observed in 50%, moderate in 50%, and heterogeneous in 64.3% of cases. Additionally, central hypodensity was observed in 64.3%, invasion of adjacent organs in 42.9%, and hepatic metastasis in 7.2% of cases. Conclusion: In the present study, the majority of tumors were found in the gastric body, with an average size of 11.5 cm, presenting with central hypodensity, heterogeneous contrast-enhancement and predominantly extraluminal growth. (author)

  16. Initial studies using the RatCAP conscious animal PET tomograph

    Energy Technology Data Exchange (ETDEWEB)

    Woody, C. [Brookhaven National Laboratory, Upton, NY (United States)]. E-mail: woody@bnl.gov; Vaska, P. [Brookhaven National Laboratory, Upton, NY (United States); Schlyer, D. [Brookhaven National Laboratory, Upton, NY (United States); Pratte, J.-F. [Brookhaven National Laboratory, Upton, NY (United States); Junnarkar, S. [Brookhaven National Laboratory, Upton, NY (United States); Park, S.-J. [Brookhaven National Laboratory, Upton, NY (United States); Stoll, S. [Brookhaven National Laboratory, Upton, NY (United States); Purschke, M. [Brookhaven National Laboratory, Upton, NY (United States); Southekal, S. [Stony Brook University, Stony Brook, NY (United States); Kriplani, A. [Stony Brook University, Stony Brook, NY (United States); Krishnamoorthy, S. [Stony Brook University, Stony Brook, NY (United States); Maramraju, S. [Stony Brook University, Stony Brook, NY (United States); Lee, D. [Brookhaven National Laboratory, Upton, NY (United States); Schiffer, W. [Brookhaven National Laboratory, Upton, NY (United States); Dewey, S. [Brookhaven National Laboratory, Upton, NY (United States); Neill, J. [Long Island University, Brookville, NY (United States); Kandasamy, A. [Brookhaven National Laboratory, Upton, NY (United States); O' Connor, P. [Brookhaven National Laboratory, Upton, NY (United States); Radeka, V. [Brookhaven National Laboratory, Upton, NY (United States); Fontaine, R. [Sherbrooke University, Sherbrooke, Que. (Canada); Lecomte, R. [Sherbrooke University, Sherbrooke, Que. (Canada)

    2007-02-01

    The RatCAP is a small, head-mounted PET tomograph designed to image the brain of a conscious rat without the use of anesthesia. The detector is a complete, high-performance 3D tomograph consisting of a 3.8 cm inside-diameter ring containing 12 block detectors, each of which is comprised of a 4x8 array of 2.2x2.2x5 mm{sup 3} LSO crystals readout with a matching APD array and custom ASIC, and has a 1.8 cm axial field of view. Construction of the first working prototype detector has been completed and its performance characteristics have been measured. The results show an intrinsic spatial resolution of 2.1 mm, a time resolution of {approx}14 ns FWHM, and a sensitivity of 0.7% at an energy threshold of 150 keV. First preliminary images have been obtained using {sup 18}F-FDG and {sup 11}C-methamphetamine, which show comparable image quality to those obtained from a commercial MicroPET R4 scanner. Initial studies have also been carried out to study stress levels in rats wearing the RatCAP.

  17. Initial studies using the RatCAP conscious animal PET tomograph

    International Nuclear Information System (INIS)

    Woody, C.; Vaska, P.; Schlyer, D.; Pratte, J.-F.; Junnarkar, S.; Park, S.-J.; Stoll, S.; Purschke, M.; Southekal, S.; Kriplani, A.; Krishnamoorthy, S.; Maramraju, S.; Lee, D.; Schiffer, W.; Dewey, S.; Neill, J.; Kandasamy, A.; O'Connor, P.; Radeka, V.; Fontaine, R.; Lecomte, R.

    2007-01-01

    The RatCAP is a small, head-mounted PET tomograph designed to image the brain of a conscious rat without the use of anesthesia. The detector is a complete, high-performance 3D tomograph consisting of a 3.8 cm inside-diameter ring containing 12 block detectors, each of which is comprised of a 4x8 array of 2.2x2.2x5 mm 3 LSO crystals readout with a matching APD array and custom ASIC, and has a 1.8 cm axial field of view. Construction of the first working prototype detector has been completed and its performance characteristics have been measured. The results show an intrinsic spatial resolution of 2.1 mm, a time resolution of ∼14 ns FWHM, and a sensitivity of 0.7% at an energy threshold of 150 keV. First preliminary images have been obtained using 18 F-FDG and 11 C-methamphetamine, which show comparable image quality to those obtained from a commercial MicroPET R4 scanner. Initial studies have also been carried out to study stress levels in rats wearing the RatCAP

  18. Manual and computerized measurement of coronal vertebral inclination on MRI images: A pilot study

    International Nuclear Information System (INIS)

    Vrtovec, T.; Likar, B.; Pernuš, F.

    2013-01-01

    Aim: A pilot study that presents a systematic approach for evaluating the variability of manual and computerized measurements of coronal vertebral inclination (CVI) on images acquired by magnetic resonance imaging (MRI). Materials and methods: Three observers identified the vertebral body corners of 28 vertebrae on two occasions on two-dimensional (2D) coronal MRI cross-sections, which served to evaluate CVI using six manual measurements (superior and inferior tangents, left and right tangents, mid-endplate and mid-wall lines). Computerized measurements were performed by evaluating CVI from the symmetry of vertebral anatomical structures of the same 28 vertebrae in 2D coronal MRI cross-sections and in three-dimensional (3D) MRI images. Results: In terms of standard deviation (SD), the mid-endplate lines proved to be the manual measurements with the lowest intra- (1.0° SD) and interobserver (1.4° SD) variability. The computerized measurements in 3D yielded even lower intra- (0.8° SD) and interobserver (1.3° SD) variability. The strongest inter-method agreement (1.2° SD) was found among lines parallel to vertebral endplates (superior tangents, inferior tangents, mid-endplate lines). The computerized measurements in 3D were most in agreement with the mid-endplate lines (1.9° SD). The estimated intra- and interobserver variabilities of standard Cobb angle measurements were equal to 1.6° SD and 2.5° SD, respectively, for manual measurements, and to 1.1° SD and 1.8° SD, respectively, for computerized measurements. Conclusion: The mid-endplate lines proved to be the most reproducible and reliable manual CVI measurements. Computerized CVI measurements based on the evaluation of the symmetry of vertebral anatomical structures in 3D were more reproducible and reliable than manual measurements

  19. Handwriting Characteristics among Secondary Students with and without Physical Disabilities: A Study with a Computerized Tool

    Science.gov (United States)

    Li-Tsang, Cecilia W. P.; Au, Ricky K. C.; Chan, Michelle H. Y.; Chan, Lily W. L.; Lau, Gloria M. T.; Lo, T. K.; Leung, Howard W. H.

    2011-01-01

    The purpose of the present study was to investigate the handwriting characteristics of secondary school students with and without physical disabilities (PD). With the use of a computerized Chinese Handwriting Assessment Tool (CHAT), it was made possible to objectively assess and analyze in detail the handwriting characteristics of individual…

  20. Computer tomographic detection of an intraspinal arachnoidal cyst

    Energy Technology Data Exchange (ETDEWEB)

    Kuckein, D; Walter, K; Paal, G

    1981-03-01

    A 46 year old female patient who after 3-4 weeks of influenza suffered from strong headaches, vomiting and rotatory vertigo was subjected to a myelograph and then to a computerized tomographic investigation due to suspect cerebrospinal fluid. The computerized tomography is better than the myelography in diagnosing intraspinal arachnoidal cysts, however this should be preceded by most accurate possible segment location.

  1. Breeding snow: an instrumented sample holder for simultaneous tomographic and thermal studies

    International Nuclear Information System (INIS)

    Pinzer, B; Schneebeli, M

    2009-01-01

    To study the recrystallization processes during temperature gradient metamorphism of snow, we developed a sample holder that allows applying well-defined and stable thermal gradients to a snow sample while it is scanned in an x-ray micro-tomograph. To this end, both the thermal insulation of the sample as well as image contrast and resolution of the tomography had to be optimized. We solved this conflict by using thin aluminum cylinders in combination with highly insulating foam. This design is light, does not corrupt image quality and provides very good thermal decoupling from the environment. The sample holder was instrumented to measure the effective conductivity of the snow sample and calibrated using five materials of known conductivity. Finite element simulations were consistent with the calibration measurements and gave insight into the internal temperature and heat flux fields. With this setup, geometric and thermal evolution of snow under realistic thermal boundary conditions like alternating temperature gradients can be measured

  2. Clamshell tomograph

    International Nuclear Information System (INIS)

    Derenzo, S. E.; Budinger, Th. F.

    1984-01-01

    In brief, the invention is a tomograph modified to be in a clamshell configuration so that the ring or rings may be moved to multiple sampling positions. The tomograph includes an array of detectors arranged in successive adjacent relative locations along a closed curve in a first position in a selected plane, and means for securing the detectors in the relative locations in a first sampling position. The securing means is movable in the plane in two sections and pivotable at one point and only one point to enable movement of at least one of the sections to a second sampling position out of the closed curve so that the ends of the section which are opposite the point are moved apart a predetermined space

  3. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    The configuration of a tomographic array in which the object can rotate about its axis is described. The X-ray detector is a cylindrical screen perpendicular to the axis of rotation. The X-ray source has a line-shaped focus coinciding with the axis of rotation. The beam is fan-shaped with one side of this fan lying along the axis of rotation. The detector screen is placed inside an X-ray image multiplier tube

  4. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    A tomographic array with the following characteristics is described. An X-ray screen serving as detector is placed before a photomultiplier tube which itself is placed in front of a television camera connected to a set of image processors. The detector is concave towards the source and is replacable. Different images of the object are obtained simultaneously. Optical fibers and lenses are used for transmission within the system

  5. Computer tomographs

    International Nuclear Information System (INIS)

    Niedzwiedzki, M.

    1982-01-01

    Physical foundations and the developments in the transmission and emission computer tomography are presented. On the basis of the available literature and private communications a comparison is made of the various transmission tomographs. A new technique of computer emission tomography ECT, unknown in Poland, is described. The evaluation of two methods of ECT, namely those of positron and single photon emission tomography is made. (author)

  6. Comparative validation of the radiographic and tomographic measurement of patellar height

    Directory of Open Access Journals (Sweden)

    Marco Antonio Schueda

    2013-09-01

    Full Text Available OBJECTIVE: To evaluate and validate the radiographic measurement of patellar height with computerized tomography scans. METHODS: Measured the patellar height through the lateral radiographic image supported by one foot and sagittal tomographic view of the knee in extension, flexion of 20°, and quadriceps contraction of 40 patients (80 knees, asymptomatic and no history of knee injuries using Insall-Salvati index. There were 20 adult females and 20 adult males. RESULTS: The height patellar index was higher in women of all images taken, in proportion. There was no statistical difference of patellar height index between the radiographics and tomographics images. CONCLUSION: The Insall-Salvati index in females was higher in all cases evaluated. Furthermore, it is possible to measure the patellar height index during tomographic study without distorting the results obtained, using to define the presence of patella alta or patella baja.

  7. A study on operators' cognitive response characteristics to the computerized working environment

    International Nuclear Information System (INIS)

    Lee, Yong Hee; Lee, Jang Soo; Suh, Sang Moon; Lee, Hyun Cheol; Jung, Kwang Tae; Lee, Dhong Ha

    1998-12-01

    Although the introduction of computerized working environment to the nuclear facilities, the study on the human factors impacts of computers and automation has not been enough like the other industries. It is necessary to prepare the way to cope with the negative aspects in spite of many positive aspects of computerization in nuclear. This study is an empirical study including the survey of the human factor concerning, especially to the cognitive response of operators' and the experiments on the error proneness. At first, we survey the design and its changes of operator interface and interaction in nuclear power plants, and conclude five human factor issues. We discuss situation awareness issues as one of the major human factor concerning, and the assessment method. Secondly, a questionnaire and interviews survey to the operator's response characteristics are performed for possible criterion measures tot he in-depth study on the cognitive characteristics. Finally, several experiments are conducted to test the error proneness. The issues and findings of this study could be utilized to any further study on the cognitive characteristic of operators to the computerized work environment

  8. A study on operators' cognitive response characteristics to the computerized working environment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Hee; Lee, Jang Soo; Suh, Sang Moon; Lee, Hyun Cheol; Jung, Kwang Tae; Lee, Dhong Ha

    1998-12-01

    Although the introduction of computerized working environment to the nuclear facilities, the study on the human factors impacts of computers and automation has not been enough like the other industries. It is necessary to prepare the way to cope with the negative aspects in spite of many positive aspects of computerization in nuclear. This study is an empirical study including the survey of the human factor concerning, especially to the cognitive response of operators' and the experiments on the error proneness. At first, we survey the design and its changes of operator interface and interaction in nuclear power plants, and conclude five human factor issues. We discuss situation awareness issues as one of the major human factor concerning, and the assessment method. Secondly, a questionnaire and interviews survey to the operator's response characteristics are performed for possible criterion measures to the in-depth study on the cognitive characteristics. Finally, several experiments are conducted to test the error proneness. The issues and findings of this study could be utilized to any further study on the cognitive characteristic of operators to the computerized work environment.

  9. Computerized cognitive training in survivors of childhood cancer: a pilot study.

    Science.gov (United States)

    Hardy, Kristina K; Willard, Victoria W; Bonner, Melanie J

    2011-01-01

    The objective of the current study was to pilot a computerized cognitive training program, Captain's Log, in a small sample of survivors of childhood cancer. A total of 9 survivors of acute lymphoblastic leukemia and brain tumors with attention and working memory deficits were enrolled in a home-based 12-week cognitive training program. Survivors returned for follow-up assessments postintervention and 3 months later. The intervention was associated with good feasibility and acceptability. Participants exhibited significant increases in working memory and decreases in parent-rated attention problems following the intervention. Findings indicate that home-based, computerized cognitive intervention is a promising intervention for survivors with cognitive late effects; however, further study is warranted with a larger sample.

  10. A hard tissue cephalometric comparative study between hand tracing and computerized tracing

    Directory of Open Access Journals (Sweden)

    Ramachandra Prabhakar

    2014-01-01

    Full Text Available Aims: To analyze and compare the angular and linear hard tissue cephalometric measurements using hand-tracing and computerized tracings with Nemoceph and Dolphin software systems. Subjects and Methods: A total of 30 cephalograms were randomly chosen for study with the following criteria, cephalograms of patients with good contrast, no distortion, and minimal radiographic artifacts were considered using the digital method (Kodak 8000 C with 12 angular and nine linear parameters selected for the study. Comparisons were determined by post-hoc test using Tukey HSD method. The N-Par tests were performed using Kruskal-Walli′s method. Statistical Analysis Used: ANOVA and post-hoc. Results: The results of this study show that there is no significant difference in the angular and linear measurements recorded. The P values were significant at 0.05 levels for two parameters, Co-A and Co-Gn with the hand-tracing method. This was significant in ANOVA and post-hoc test by Tukey HSD method. Conclusions: This study of comparison provides support for transition from digital hand to computerized tracing methodology. In fact, digital computerized tracings were easier and less time consuming, with the same reliability irrespective of each method of tracing.

  11. Quantitative inspection by computerized tomography

    International Nuclear Information System (INIS)

    Lopes, R.T.; Assis, J.T. de; Jesus, E.F.O. de

    1989-01-01

    The computerized Tomography (CT) is a method of nondestructive testing, that furnish quantitative information, that permit the detection and accurate localization of defects, internal dimension measurement, and, measurement and chart of the density distribution. The CT technology is much versatile, not presenting restriction in relation to form, size or composition of the object. A tomographic system, projected and constructed in our laboratory is presented. The applications and limitation of this system, illustrated by tomographyc images, are shown. (V.R.B.)

  12. Studies on clinical significances of intracranial meningiomas in computerized tomography

    International Nuclear Information System (INIS)

    Kasamo, Shizuya

    1986-01-01

    Meningioma has been widely assumed to be a representative benign tumor among the primary intracranial tumors. However, many problems still remain in the clinical management of meningioma. The author had studied the clinical significance of meningiomas from the 104 cases he had experienced. CT was performed in 101 cases of them. In this paper, CT findings of meningioma were initially analyzed with reference to correlations of symptomatological and histopathological features. The mechanism of occurrence of the peritumoral low density (PTL) found on CT was discussed under an identification of cerebral edema. Secondly, the endocrinological environment was studied since certain hormonal changes might influence the growth and spread of the tumor. Estrogen receptor (ER) and progesterone receptor (PgR) in the tumor tissue were studied and discussed as to their clinical evaluation. Thirdly, fine structures in 12 cases of meningiomas were studied by transmission electron microscopy (TEM). And the correlation between the TEM findings and clinical and endocrinological findings were discussed. From these results, the author drew the following conclusions; 1) There was no correlation between the tumor and the hormonal environment, but there is a suggestive evidence that meningioma might be hormone-dependent. 2) The factors of occurrence of PTL were tumor size, location of tumor and histological subtype. And from the findings of TEM, one of the mechanisms of occurrence of PTL might be due to secretion of an edema factor from tumor tissue. 3) Close correlation between tumor size and period from onset to admission was found, and when the tumor size (xmm) was measured on CT, the time of occurrence of tumor (y months ago) could be roughly calculated from the following equation; y = 1.9x - 13.3 (r = 0.683, p < 0.01). (J.P.N.)

  13. C-11-labeled octadecylamine, a potential agent for positron tomographic pulmonary metabolism studies

    International Nuclear Information System (INIS)

    Washburn, L.C.; Wallace, R.T.; Byrd, B.L.; Sun, T.T.; Coffey, J.L.; Hubner, K.F.

    1984-01-01

    C-11-Labeled straight-chain primary aliphatic amines are rapidly and selectively sequestered by lung endothelial cells, making these agents potentially useful for positron tomographic studies of the lung as a metabolic organ. However, because amines having straight chains containing 4 to 13 carbon atoms are rapidly catabolized in vivo with loss of radiolabel, quantitation of pulmonary concentration is difficult. The authors have studied the effect of structural changes on the uptake and retention of primary aliphatic amines in rat lung and found that the metabolic loss form the lung decreased with increasing length of the straight carbon chain. In fact, the lung concentration of octadecylamine, a straight-chain amine with 18 carbon atoms, was constant between 1 and 30 minutes after intravenous administration. This highly insoluble amine was solubilized using 3% aqueous human serum albumin. Unilateral, radiation-induced lung injury in the rat was used as a model to study the potential of C-11-labeled octadecylamine. Radiation-damaged (3000 and 5000 Rads) lungs had significantly lower 15-minute uptakes of the labeled amine than the corresponding nonirradiated lungs. However, at 8000 Rads the concentration in both lungs was greatly suppressed, indicating that the decrease in metabolism becomes systemic at high radiation doses. These results suggest that C-11-labeled octadecylamine is a potentially useful agent for quantitative evaluation of pulmonary metabolism by positron tomography

  14. A study of the decoding of multiple pinhole coded aperture RI tomographic images

    International Nuclear Information System (INIS)

    Hasegawa, Takeo; Kobayashi, Akitoshi; Nishiyama, Yutaka; Akagi, Kiyoshi; Uehata, Hiroshi

    1981-01-01

    In order to obtain a radioisotope (RI) tomographic image, there are various, methods, including the RCT method, Time Modulate method, and Multiple Pinhole Coded Aperture (MPCA) method and others. The MPCA method has several advantages. Using the MPCA method, there is no need to move either the detector or the patient, Furthermore, the generally used γ-camera may be used without any alterations. Due to certain problems in reconstructing the tomographic image, the use of the MPCA method in clinical practice is limited to representation of small organs (e.g. heart) using the 7-Pinhole collimator. This research presents an experimental approach to overcome the problems in reconstruction of tomographic images of large organs (organs other than the heart, such as the brain, liver, lung etc.) by introducing a reconstruction algorithm and correction software into the MPCA method. There are 2 main problems in MPCA image reconstruction: (1) Due to the rounding-off procedure, there is both point omission and shifting of point coordinates. (2) The central portion is characterized by high-counts. Both of these problems were solved by incorporating a reconstruction algorithm and a correction function. The resultant corrected tomographic image was processed using a filter derived from subjecting a PSF to a Fourier transform. Thus, it has become possible to obtain a high-quality tomographic image of large organs for clinical use. (author)

  15. A new electrode-mesh tomograph for advanced studies on bubbly flow characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Richter, St.; Aritomi, M. [Tokyo Institute of Technology, Tokyo (Japan)

    2001-07-01

    For studies on the characteristics of bubble flow in a rectangular channel (20 x 100 mm) a new electrode-mesh tomograph have been applied. The measuring principle is based on local conductivity measurement and a signal concerning. The applied sensor scans the local void fraction distribution in 2 parallel planes, separated 1.5 mm in flow direction, with a resolution of 3.0 x 2.2 mm and a overall sampling rate of 1200 Hz (all 256 points). Algorithm for the calculation of the local instantaneous void fraction distribution and the true gas velocity are presented. Based on these values the approximate shape of bubbles have been reconstructed and the gas volume flow through the sensor evaluated. The superficial gas velocity as well as the local distribution of the gas volume flux can be calculated. An extensive sensitivity study illustrating the applicability and accuracy is presented, based on experimental observations as well as theoretical considerations. The evaluated results are compared with high-speed video observations of the flow field as well as data comparing the reconstructed volume flow with measurements by a laminar flow meter. Good agreement can be stated. (author)

  16. Clinical studies of pigmented lesions in human skin by using a multiphoton tomograph

    Science.gov (United States)

    Balu, Mihaela; Kelly, Kristen M.; Zachary, Christopher B.; Harris, Ronald M.; Krasieva, Tatiana B.; König, Karsten; Tromberg, Bruce J.

    2013-02-01

    In vivo imaging of pigmented lesions in human skin was performed with a clinical multiphoton microscopy (MPM)-based tomograph (MPTflex, JenLab, Germany). Two-photon excited fluorescence was used for visualizing endogenous fluorophores such as NADH/FAD, keratin, melanin in the epidermal cells and elastin fibers in the dermis. Collagen fibers were imaged by second harmonic generation. Our study involved in vivo imaging of benign melanocytic nevi, atypical nevi and melanoma. The goal of this preliminary study was to identify in vivo the characteristic features and their frequency in pigmented lesions at different stages (benign, atypical and malignant) and to evaluate the ability of in vivo MPM to distinguish atypical nevi from melanoma. Comparison with histopathology was performed for the biopsied lesions. Benign melanocytic nevi were characterized by the presence of nevus cell nests at the epidermal-dermal junction. In atypical nevi, features such as lentiginous hyperplasia, acanthosis and architectural disorder were imaged. Cytological atypia was present in all the melanoma lesions imaged, showing the strongest correlation with malignancy. The MPM images demonstrated very good correlation with corresponding histological images, suggesting that MPM could be a promising tool for in vivo non-invasive pigmented lesion diagnosis, particularly distinguishing atypical nevi from melanoma.

  17. A morphological study of the mandibular molar region using reconstructed helical computed tomographic images

    International Nuclear Information System (INIS)

    Tsuno, Hiroaki; Noguchi, Makoto; Noguchi, Akira; Yoshida, Keiko; Tachinami, Yasuharu

    2010-01-01

    This study investigated the morphological variance in the mandibular molar region using reconstructed helical computed tomographic (CT) images. In addition, we discuss the necessity of CT scanning as part of the preoperative assessment process for dental implantation, by comparing the results with the findings of panoramic radiography. Sixty patients examined using CT as part of the preoperative assessment for dental implantation were analyzed. Reconstructed CT images were used to evaluate the bone quality and cross-sectional bone morphology of the mandibular molar region. The mandibular cortical index (MCI) and X-ray density ratio of this region were assessed using panoramic radiography in order to analyze the correlation between the findings of the CT images and panoramic radiography. CT images showed that there was a decrease in bone quality in cases with high MCI. Cross-sectional CT images revealed that the undercuts on the lingual side in the highly radiolucent areas in the basal portion were more frequent than those in the alveolar portion. This study showed that three-dimensional reconstructed CT images can help to detect variances in mandibular morphology that might be missed by panoramic radiography. In conclusion, it is suggested that CT should be included as an important examination tool before dental implantation. (author)

  18. Investigating the correlation between computerized tomography changes and quantitative consciousness disturbances in stroke patients

    International Nuclear Information System (INIS)

    Toneva, Yu.; Manchev, I.; Tsolova, M.

    1997-01-01

    One-hundred and nine patients undergo computerized tomographic (CT) and clinical investigations. The correlation between CT finding and quantitative consciousness disturbances has been studied. The somatic, neurologic and mental states are evaluated, and the changes in consciousness are classified according to a 4-degree rating system adopted in this country, namely: obnubilation, somnolence, sopor and coma. For the purpose a computerized tomograph CE 10000 is used. Cerebral infarctions in the right middle cerebral artery pool predominate. Here the disturbances are of a milder degree - obnubilation and somnolence. In stroke syndrome cases the states of sopor and coma are more frequent which may be explained with the rather severely manifested brain edema. In either form of cerebrovascular disease the quantitative disorders of consciousness are not dependent on the location of the accident in the dominant hemisphere. They are directly related to the CT documented size of pathological focus

  19. Computed tomographic (CT) study of watershed area supplied by the posterior inferior cerebellar artery (PICA)

    International Nuclear Information System (INIS)

    Nozaki, Junichi; Hirose, Satoshi; Hosotani, Kazuo; Kubota, Tetsuya; Kubota, Norihiko.

    1990-01-01

    Thirteen patients with clinical and computed tomographic (CT) evidence of cerebellar infarction were examined during 1987-1989. Six patients had onset of cerebellar infarction at ages ranging from 45 to 69, and seven patients had onset at ages over 70. In thirteen cases, we observed infarction in the inferior region of the cerebellum, and we studied these cases. CT demonstrated decreased density in 4 distinct anatomic areas. These areas are listed below, with estimation of the distribution of the hemispheric arteries of the posterior inferior cerebellar artery (PICA): Group 1 - posterior medial area, probably territory of the inferior vermian branch, tonsillar branch and/or medial artery of the hemispheric artery of the PICA; Group 2 - posterior intermediate area, probably territory of the intermediate artery of the hemispheric artery of the PICA; Group 3 - area including both areas of group 1 and group 3; Group 4 - lateral area, just posterior to pyramis, probably territory of the anterior inferior cerebellar artery and/or lateral artery of the hemispheric artery of PICA. The medial and intermedial cerebellar hemispheric segments were most commonly affected but the lateral segment was not. The PICA least frequently supplied the lateral segments. While the anterior inferior cerebellar artery usually anastomoses with the lateral artery of the hemispheric artery of the PICA. These vascular territories may provide good collateral circulation to this segment. And we also estimate the distribution of the PICA by the CT findings. (author)

  20. Methodological study of radionuclide tomographic phase analysis in localization of accessory conduction pathway in patients with wolff-parkinson-white syndrome

    International Nuclear Information System (INIS)

    Wo Jinshan; Zhu Junren; Li Zhishan

    1994-01-01

    In this study, the methodology of tomographic phase analysis to detect the site of accessory conduction pathway (ACP) in patients with Wolff-Parkinson-White syndrome was presented. We analyzed the major factors that affect image reconstruction, selection of tomographic planes and phase analysis, also discussed the key step for reconstruction short-axial section that parallel and closest to the level of atrio-ventricular rings. Of five patients undergoing this procedure prior to surgery, tomographic phase analysis correctly identified the site of ACP confirmed by epicardial mapping in all of the five patients. Our results suggest this approach to be an objective, clear and correct one for localizing ACP

  1. Computerized three-dimensional normal atlas

    International Nuclear Information System (INIS)

    Mano, Isamu; Suto, Yasuzo; Suzuki, Masataka; Iio, Masahiro.

    1990-01-01

    This paper presents our ongoing project in which normal human anatomy and its quantitative data are systematically arranged in a computer. The final product, the Computerized Three-Dimensional Normal Atlas, will be able to supply tomographic images in any direction, 3-D images, and coded information on organs, e.g., anatomical names, CT numbers, and T 1 and T 2 values. (author)

  2. Geometrical efficiency in computerized tomography: generalized model

    International Nuclear Information System (INIS)

    Costa, P.R.; Robilotta, C.C.

    1992-01-01

    A simplified model for producing sensitivity and exposure profiles in computerized tomographic system was recently developed allowing the forecast of profiles behaviour in the rotation center of the system. The generalization of this model for some point of the image plane was described, and the geometrical efficiency could be evaluated. (C.G.C.)

  3. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhkio

    1985-03-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images.

  4. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhiko.

    1985-01-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images. (author)

  5. Computerized analysis of isometric tension studies provides important additional information about vasomotor activity

    Directory of Open Access Journals (Sweden)

    Vincent M.B.

    1997-01-01

    Full Text Available Concentration-response curves of isometric tension studies on isolated blood vessels are obtained traditionally. Although parameters such as Imax, EC50 and pA2 may be readily calculated, this method does not provide information on the temporal profile of the responses or the actual nature of the reaction curves. Computerized data acquisition systems can be used to obtain average data that represent a new source of otherwise inaccessible information, since early and late responses may be observed separately in detail

  6. Results of a comparison study using tomographic and segmented gamma scanner technology

    International Nuclear Information System (INIS)

    Hurd, J.R.; Estep, R.J.; Dittrich, S.; Grimes, L.V.; Gomez, C.D.

    2004-01-01

    In order to support the many on-going research and programmatic activities at Los Alamos Plutonium and Chemistry and Metallurgy Research (CMR) Facilities in as accurate, efficient, and cost-effective manner possible, every reasonable effort is made to equip the nondestructive assay (NDA) laboratories with the most modern and technologically advanced instrumentation available. Recently, new state-of-the-art tomographic gamma scanner (TGS) instruments were installed to replace aging and outmoded segmented gamma scanner (SGS) instruments. Through the implementation of a translation axis, in addition to the vertical and rotation axes of the SGS, the TGS technique is able to employ axial tomography to determine the spatial distribution and quantity of nuclear material using high-resolution gamma-ray spectroscopy. Because the attenuation matrix and source distributions are known more accurately than with the SGS technology, biases due to matrix and source distributions should be reduced. In principle, a single calibration should suffice for the determination of isotopic mass for a wide range of material and matrix types. A number of questions naturally arise concerning these purported advantages of the TGS. Perhaps the most fundamental of these is to understand how the TGS measurement results compare with those of a typical SGS on the same well-characterized standards differing in matrix and material type. To that end, the TGS operating parameters were optimized to assay 55-gallon drum waste identical to that measured by our SGS. The calibration and measurement results on these standards, placed in typical low-density waste matrices, are presented and discussed. These results should enable more confident use of the TGS as well as point the way toward even more studies to enable more effective employment of the new TGS technology.

  7. Tomographic apparatus for reconstructing planar slices from non-absorbed and non-scattered radiation

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus which can be used in computerized tomographic systems for producing a fan shaped beam, detectors to be used in conjunction with the source and equipment for rotating the source supports are described. (U.K.)

  8. Impact of attenuation correction strategies on the quantification of High Resolution Research Tomograph PET studies

    International Nuclear Information System (INIS)

    Velden, Floris H P van; Kloet, Reina W; Berckel, Bart N M van; Molthoff, Carla F M; Jong, Hugo W A M de; Lammertsma, Adriaan A; Boellaard, Ronald

    2008-01-01

    In this study, the quantitative accuracy of different attenuation correction strategies presently available for the High Resolution Research Tomograph (HRRT) was investigated. These attenuation correction methods differ in reconstruction and processing (segmentation) algorithms used for generating a μ-image from measured 2D transmission scans, an intermediate step in the generation of 3D attenuation correction factors. Available methods are maximum-a-posteriori reconstruction (MAP-TR), unweighted OSEM (UW-OSEM) and NEC-TR, which transforms sinogram values back to their noise equivalent counts (NEC) to restore Poisson distribution. All methods can be applied with or without μ-image segmentation. However, for MAP-TR a μ-histogram is a prior during reconstruction. All possible strategies were evaluated using phantoms of various sizes, simulating preclinical and clinical situations. Furthermore, effects of emission contamination of the transmission scan on the accuracy of various attenuation correction strategies were studied. Finally, the accuracy of various attenuation corrections strategies and its relative impact on the reconstructed activity concentration (AC) were evaluated using small animal and human brain studies. For small structures, MAP-TR with human brain priors showed smaller differences in μ-values for transmission scans with and without emission contamination (<8%) than the other methods (<26%). In addition, it showed best agreement with true AC (deviation <4.5%). A specific prior designed to take into account the presence of small animal fixation devices only very slightly improved AC precision to 4.3%. All methods scaled μ-values of a large homogeneous phantom to within 4% of the water peak, but MAP-TR provided most accurate AC after reconstruction. However, for clinical data MAP-TR using the default prior settings overestimated the thickness of the skull, resulting in overestimations of μ-values in regions near the skull and thus in incorrect

  9. Computer tomographic detection of an intraspinal arachnoidal cyst

    International Nuclear Information System (INIS)

    Kuckein, D.; Walter, K.; Paal, G.; Staedtisches Krankenhaus Harlaching, Muenchen

    1981-01-01

    A 46 year old female patient who after 3-4 weeks of influenza suffered from strong headaches, vomiting and rotatory vertigo was subjected to a myelograph and then to a computerized tomographic investigation due to suspect cerebrospinal fluid. The computerized tomography is better than the myelography in diagnosing intraspinal arachnoidal cysts, however this should be preceded by most accurate possible segment location. (MG) [de

  10. Sensitivity studies using the TRNSM 2 computerized model for the NRC physical protection project. Final report

    International Nuclear Information System (INIS)

    Anderson, G.M.

    1979-08-01

    A computerized model of the transportation system for shipment of nuclear fuel cycle materials is required to investigate the effects on fleet size, fleet composition and efficiency of fleet utilization resulting from changes in a variety of physical and regulatory factors, including shipping requirements, security regulations, work rules, maintenance requirements, and vehicle capacities. Such a model has been developed which provides a capability for complete sizing requirements studies of a combined aircraft and truck fleet. This report presents the results of a series of sensitivity studies performed using this model. These studies include the effects of the intinerary optimization criteria, work rules, and maintenance policies. These results demonstrate the effectiveness and versatility of the model for investigating the effects of a wide variety of physical and regulatory factors on the transportation fleet

  11. A Case Study of Different Types of Arguments Emerging from Explorations in an Interactive Computerized Environment

    Science.gov (United States)

    Lavy, Ilana

    2006-01-01

    This paper presents a description of the different types of arguments that emerged as two students, working in a computerized environment, engaged in an investigation of several number theory concepts. The emerging arguments are seen as a result of the influence of the computerized environment together with collaborative learning. Using…

  12. The Impact of Computerization on Archival Finding Aids: A RAMP Study.

    Science.gov (United States)

    Kitching, Christopher

    This report is based on a questionnaire sent to 32 selected National Archives and on interviews with archivists from eight countries. Geared to the needs of developing countries, the report covers: (1) the impact of computerization on finding aids; (2) advantages and problems of computerization, including enhanced archival control, integration of…

  13. Feasibility study for the computerized automation of the Laboratory Services Branch of EPA Region IV

    International Nuclear Information System (INIS)

    Boyle, W.G. Jr.; Barton, G.W. Jr.; Taber, L.

    1978-01-01

    This report is a study of the feasibility of computerized automation of the Laboratory Services Branch of the Environmental Protection Agency's Region IV. The LSB provides chemical analytical support for a number of EPA divisions; its primary function at present is compliance monitoring, field surveys, and oil identification. Automation of the LSB is not only feasible but also highly desirable. Automation systems are proposed that will make major improvements in analytical capacity, quality control, sample management, and reporting capabilities. Most of these automation systems are similar to those already developed and installed at other EPA laboratories. These systems have options that include limited modifications suggested as a result of the study of the LSB Laboratory, and also include communications hardware and software for a Sample File Control host computer. It is estimated that the initial cost of three of the four options considered would be recouped in approximately three years through increased capacity and efficiency of operation

  14. Thanatophoric dysplasia: case report of an autopsy complemented by postmortem computed tomographic study

    Directory of Open Access Journals (Sweden)

    Éber Emanuel Mayoral

    2014-06-01

    Full Text Available Thanatophoric dysplasia (TD is one of the most common lethal skeletal dysplasias, which was first designated as thanatophoric dwarfism and described in 1967. The authors report a case of a Caucasian girl with TD, born to a 31-year-old woman without comorbidities. The newborn presented respiratory distress immediately after delivery, progressing to death in less than 2 hours. An autopsy was carried out after postmortem tomographic examination. The autopsy findings depicted extensive malformations of the skeletal system and the brain. The aim of this report is to discuss the pathogenesis and correlate the morphologic features of TD that were disclosed at the tomography and the autopsy.

  15. Industrial dynamic tomographic reconstruction

    International Nuclear Information System (INIS)

    Oliveira, Eric Ferreira de

    2016-01-01

    The state of the art methods applied to industrial processes is currently based on the principles of classical tomographic reconstructions developed for tomographic patterns of static distributions, or is limited to cases of low variability of the density distribution function of the tomographed object. Noise and motion artifacts are the main problems caused by a mismatch in the data from views acquired in different instants. All of these add to the known fact that using a limited amount of data can result in the presence of noise, artifacts and some inconsistencies with the distribution under study. One of the objectives of the present work is to discuss the difficulties that arise from implementing reconstruction algorithms in dynamic tomography that were originally developed for static distributions. Another objective is to propose solutions that aim at reducing a temporal type of information loss caused by employing regular acquisition systems to dynamic processes. With respect to dynamic image reconstruction it was conducted a comparison between different static reconstruction methods, like MART and FBP, when used for dynamic scenarios. This comparison was based on a MCNPx simulation as well as an analytical setup of an aluminum cylinder that moves along the section of a riser during the process of acquisition, and also based on cross section images from CFD techniques. As for the adaptation of current tomographic acquisition systems for dynamic processes, this work established a sequence of tomographic views in a just-in-time fashion for visualization purposes, a form of visually disposing density information as soon as it becomes amenable to image reconstruction. A third contribution was to take advantage of the triple color channel necessary to display colored images in most displays, so that, by appropriately scaling the acquired values of each view in the linear system of the reconstruction, it was possible to imprint a temporal trace into the regularly

  16. Feasibility study for the computerized automation of the Annapolis Field Office of EPA region III

    International Nuclear Information System (INIS)

    Ames, H.S.; Barton, G.W. Jr.; Bystroff, R.I.; Crawford, R.W.; Kray, A.M.; Maples, M.D.

    1976-08-01

    This report describes a feasibility study for computerized automation of the Annapolis Field Office (AFO) of EPA's Region III. The AFO laboratory provides analytical support for a number of EPA divisions; its primary function at present is analysis of water samples from rivers, estuaries, and the ocean in the Chesapeake Bay area. Automation of the AFO laboratory is found to be not only feasible but also highly desirable. An automation system is proposed which will give major improvements in analytical capacity, quality control, sample management, and reporting capabilities. This system is similar to the LLL-developed automation systems already installed at other EPA laboratories, with modifications specific to the needs of the AFO laboratory and the addition of sample file control. It is estimated that the initial cost of the system, nearly $300,000, would be recouped in about three years by virtue of the increased capacity and efficiency of operation

  17. Muscle area and muscle density of osteoarthritis of the knee joint studied by computerized tomography

    International Nuclear Information System (INIS)

    Suzuki, Nobuharu; Onosawa, Toshihiro; Shibata, Minoru; Yamashita, Izumi; Yoshimura, Shinichiro; Muraoka, Shunichi; Asano, Akira

    1985-01-01

    In order to investigate the etiology and pathology of osteoarthritis of the knee joints (OA), the areas and density of the muscle 10 cm above the knee were compared using computerized tomography (CT) in 26 knees from 19 normal persons, 30 knees from 17 patients with OA, and 14 knees from 7 patients with rheumatoid arthritis. The areas of the quadriceps musculi of thigh were remarkably decreased and the areas of the flexor musculi were comparatively maintained in the patients with OA. Muscle density was markedly lowered in the musculi semimembranosus and biceps femoris long head. Fatty tissues were seen in the whole area of the venter on CT in some of the patients with OA. These findings are considered to be of major importance when studying the etiology of OA. (Namekawa, K.)

  18. Influence of Heat Treatment of Nickel-Titanium Rotary Endodontic Instruments on Apical Preparation: A Micro-Computed Tomographic Study.

    Science.gov (United States)

    de Almeida, Bernardo Corrêa; Ormiga, Fabíola; de Araújo, Marcos César Pimenta; Lopes, Ricardo Tadeu; Lima, Inayá Corrêa Barbosa; dos Santos, Bernardo Camargo; Gusman, Heloisa

    2015-12-01

    The aim of this study was to make a 3-dimensional comparison of the canal transportation and changes in apical geometry using micro-computed tomographic imaging after canal preparation with K3 (SybronEndo, Orange, CA) and K3XF (SybronEndo) file systems. Twenty-eight mandibular molars were randomly divided into 2 groups according to the rotary system used in instrumentation: K3 or K3XF. The specimens were scanned by micro-computed tomographic imaging before and after instrumentation. Images before and after instrumentation from each group were compared with regard to canal volume, surface area, and structure model index (SMI) (paired t test, P instrumentation, the canals from each group were compared regarding the changes in volume, surface area, SMI, and canal transportation in the last 4 apical mm (t test, P Instrumentation with the 2 rotary systems significantly changed the canal volume, surface area, and SMI (P instrument types concerning these parameters (P > .05). There were no significant differences between the 2 groups with regard to canal transportation in the last 4 apical mm (P > .05). Both rotary systems showed adequate canal preparations with reduced values of canal transportation. Heat treatment did not influence changes in root canal geometry in the apical region. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Tomographic imaging of rock conditions ahead of mining using the shearer as a seismic source - A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Luo, X.; King, A.; Van de Werken, M. [CSIRO, Brisbane, Qld. (Australia)

    2009-11-15

    Roof falls due to poor rock conditions in a coal longwall panel may threaten miner's life and cause significant interruption to mine production. There has been a requirement for technologies that are capable of imaging the rock conditions in longwall coal mining, ahead of the working face and without any interruption to production. A feasibility study was carried out to investigate the characteristics of seismic signals generated by the continuous coal cutter (shearer) and recorded by geophone arrays deployed ahead of the working face, for the purpose of seismic tomographic imaging of roof strata condition before mining. Two experiments were conducted at a coal mine using two arrays of geophones. The experiments have demonstrated that the longwall shearer generates strong and low-frequency (similar to 40 Hz) seismic energy that can be adequately detected by geophones deployed in shallow boreholes along the roadways as far as 300 m from the face. Using noise filtering and signal cross correlation techniques, the seismic arrival times associated with the shearer cutting can be reliably determined. It has proved the concept that velocity variations ahead of the face can be mapped out using tomographic techniques while mining is in progress.

  20. Computed tomographic study of 50 patients with hypodense hepatic injuries in childhood; Estudo de 50 casos por tomografia computadorizada de lesoes hipodensas hepaticas fundamentais na infancia

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Ines Minniti Rodrigues; Alvares, Beatriz Regina; Baracat, Jamal; Martins, Daniel Lahan [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Ciencias Medicas. Dept. de Radiologia]. E-mail: iminniti@fcm.unicamp.br; Pereira, Ricardo Minniti Rodrigues [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2006-03-15

    Objective: To describe the different tomographic findings in hypodense hepatic lesions in children and its differential diagnosis. Materials and methods: computed tomographic studies were obtained from 50 patients (age range: 0-16 years) with low-density liver lesions previously diagnosed by ultrasound. Images were made before and after administration of intravenous contrast medium. Image findings were analyzed and afterwards correlated with anatomopathological diagnosis. Results: forty-seven of 50 cases were confirmed, 30 by anatomopathological diagnosis. Most of then were benign lesions, hemangioma in 20%. Such lesions presented a homogeneous contrast absorption, mainly at the delayed phase, differing from malignant lesions. Metastasis was the most frequently found malignant lesion (18%). Conclusion: computed tomographic study is of great value in complementing the diagnosis of hypodense hepatic lesions in children, and must follow ultrasound diagnosis as a routine procedure. (author)

  1. Experimental studies of computerized procedures and team size in nuclear power plant operations

    International Nuclear Information System (INIS)

    Huang, F.-H.; Hwang, S.-L.

    2009-01-01

    The operation of a nuclear power plant is so complex that it requires teamwork. To support team performance, a system need to provide all team members integrated information displays as well as decision aids (e.g., computerized procedures). Two experiments were conducted to investigate the effects of computerized procedures and team size on operating performance. Forty-five participants were involved in the experiments. Each participant executed decision and action tasks to deal with alarm signals, while detecting occasional system errors in the interface. Results showed that effects of computerized procedures were significant on various performance indicators, such as operation time, operation errors, and learning effect, and that two operators would be a satisfactory size in the teamwork system providing computerized procedures

  2. The Study on Radioactive Nuclide Distributions within a Fuel Rod by Tomographic Gamma Scanning Method

    International Nuclear Information System (INIS)

    Quanhu, Zhang; Lee, H. K.; Hong, K. P.; Choo, Y. S.; Kim, D. S.

    2005-06-01

    Based on the specified need of the IMEF, the feasibility of Tomographic Gamma Scanning (TGS) technique has been investigated for its potential for non-destructive gamma scanning measurements of irradiated fuel rods. TGS technique has been developed for determining some radioactive isotopes' distributions of a fuel rod in hot cell. The results obtained from the simulation model extracting from real gamma scanning experimental condition in this work by new developed computer simulation codes confirmed that the gamma emission TGS technique has potential for determination of radioactive isotopes' distributions of a fuel rod. In order to verify the simulation codes, we have designed several computation schemes for both 3 by 3 and 10 by 10 fuel rod model under present situation at M1 hot cell in IMEF. The results which relative errors are less than 10% show that we have simulated and implemented determination of radioactive isotopes' distributions on simulated fuel rod by TGS technique successfully

  3. Studies of discrete symmetries in a purely leptonic system using the Jagiellonian Positron Emission Tomograph

    Directory of Open Access Journals (Sweden)

    Moskal P.

    2016-01-01

    Full Text Available Discrete symmetries such as parity (P, charge-conjugation (C and time reversal (T are of fundamental importance in physics and cosmology. Breaking of charge conjugation symmetry (C and its combination with parity (CP constitute necessary conditions for the existence of the asymmetry between matter and antimatter in the observed Universe. The presently known sources of discrete symmetries violations can account for only a tiny fraction of the excess of matter over antimatter. So far CP and T symmetries violations were observed only for systems involving quarks and they were never reported for the purely leptonic objects. In this article we describe briefly an experimental proposal for the test of discrete symmetries in the decays of positronium atom which is made exclusively of leptons. The experiments are conducted by means of the Jagiellonian Positron Emission Tomograph (J-PET which is constructed from strips of plastic scintillators enabling registration of photons from the positronium annihilation. J-PET tomograph together with the positronium target system enable to measure expectation values for the discrete symmetries odd operators constructed from (i spin vector of the ortho-positronium atom, (ii momentum vectors of photons originating from the decay of positronium, and (iii linear polarization direction of annihilation photons. Linearly polarized positronium will be produced in the highly porous aerogel or polymer targets, exploiting longitudinally polarized positrons emitted by the sodium 22Na isotope. Information about the polarization vector of orthopositronium will be available on the event by event basis and will be reconstructed from the known position of the positron source and the reconstructed position of the orthopositronium annihilation. In 2016 the first tests and calibration runs are planned, and the data collection with high statistics will commence in the year 2017.

  4. Application of tomographic inversion in studying airglow in the mesopause region

    Directory of Open Access Journals (Sweden)

    T. Nygrén

    Full Text Available It is pointed out that observations of periodic nightglow structures give excellent information on atmospheric gravity waves in the mesosphere and lower thermosphere. The periods, the horizontal wavelengths and the phase speeds of the waves can be determined from airglow images and, using several cameras, the approximate altitude of the luminous layer can also be determined by triangulation. In this paper the possibility of applying tomographic methods for reconstructing the airglow structures is investigated using numerical simulations. A ground-based chain of cameras is assumed, two-dimensional airglow models in the vertical plane above the chain are constructed, and simulated data are calculated by integrating the models along a great number of rays with different elevation angles for each camera. After addition of random noise, these data are then inverted to obtain reconstructions of the models. A tomographic analysis package originally designed for satellite radiotomography is used in the inversion. The package is based on a formulation of stochastic inversion which allows the input of a priori information to the solver in terms of regularization variances. The reconstruction is carried out in two stages. In the first inversion, constant regularization variances are used within a wide altitude range. The results are used in determining the approximate altitude range of the airglow structures. Then, in the second inversion, constant non-zero regularization variances are used inside this region and zero variances outside it. With this method reliable reconstructions of the models are obtained. The number of cameras as well as their separations are varied in order to find out the limitations of the method.

    Key words. Tomography · Airglow · Mesopause · Gravity waves

  5. Three-dimensional computerized mobilization of the cervical spine for the treatment of chronic neck pain: a pilot study.

    Science.gov (United States)

    River, Yaron; Aharony, Shelly; Bracha, Jillian; Levital, Tamir; Gerwin, Robert

    2014-07-01

    Manual therapies for chronic neck pain are imprecise, inconsistent, and brief due to therapist fatigue. A previous study showed that computerized mobilization of the cervical spine in the sagittal plane is a safe and potentially effective treatment of chronic neck pain. To investigate the safety and efficacy of computerized mobilization of the cervical spine in a three-dimensional space for the treatment of chronic neck pain. Pilot, open trial. Physical therapy outpatient department. Nine patients with chronic neck pain. A computerized cradle capable of three-dimensional neck mobilizations was used. Treatment sessions lasted 20 minutes, biweekly, for six weeks. Visual analog scale (VAS) for pain, cervical range of motion (CROM), neck disability index (NDI), joint position error (JPE), and muscle algometry. Comparing baseline at week one with week six (end of treatment), the VAS scores dropped by 2.9 points (P pain threshold in any muscle tested. There were no significant adverse effects. These preliminary results demonstrate that this novel, computerized, three-dimensional cervical mobilization device is probably safe. The data also suggest that this method is effective in alleviating neck pain and associated headache, and in increasing the CROM, although the sample size was small in this open trial. Wiley Periodicals, Inc.

  6. Study on computerized presentation of emergency procedures of a nuclear plant (step 2). The guidelines of the prototype of the computerized procedure presentation system

    International Nuclear Information System (INIS)

    Niwa, Yuji; Hollnagel, E.; Iwaki, Toshio.

    1995-01-01

    New methods of information presentation and interface design are changing the working conditions in the modern Nuclear Power Plant (NPP) control room. One area receiving considerable attention is that of Emergency Operating Procedures (EOPs), which plays an essential role in NPPs. Conventionally procedures are presented in a hard copy form. However developments in information technology have offered new opportunities for the computerization of such procedures. Consideration for the first stage of computerization should be focused upon the presentation of procedures. The specification of the computerized presentation of procedures is discussed with respect to the issues which were central to the project: navigation through procedures; formatting and presentation of procedures; and process monitoring. Issues that would be included in more advanced systems, such as help and explanation facilities features, and process linking, are also discussed. This paper deals with the specific design guidelines that were implemented for the computerization of procedure presentation. Issues of principal concern that were identified from this experience are highlighted, such as the relationship between procedure presentation and format; the registration of progress through a procedure; compensation for the limitations of computer displays versus printed documents; and the way in which the added capabilities of computerized presentation can be generally utilized in the operators' working environment. (author)

  7. Radiographic and tomographic study of the elbow joint in dogs; Avaliacao morfologica e morfometrica da articulacao umerorradioulnar em caes atraves de exames radiograficos e por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C., E-mail: anacarol@usp.br [Universidade de Sao Paulo (FMVZ/USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia

    2017-02-15

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  8. Information security risk management for computerized health information systems in hospitals: a case study of Iran.

    Science.gov (United States)

    Zarei, Javad; Sadoughi, Farahnaz

    2016-01-01

    In recent years, hospitals in Iran - similar to those in other countries - have experienced growing use of computerized health information systems (CHISs), which play a significant role in the operations of hospitals. But, the major challenge of CHIS use is information security. This study attempts to evaluate CHIS information security risk management at hospitals of Iran. This applied study is a descriptive and cross-sectional research that has been conducted in 2015. The data were collected from 551 hospitals of Iran. Based on literature review, experts' opinion, and observations at five hospitals, our intensive questionnaire was designed to assess security risk management for CHISs at the concerned hospitals, which was then sent to all hospitals in Iran by the Ministry of Health. Sixty-nine percent of the studied hospitals pursue information security policies and procedures in conformity with Iran Hospitals Accreditation Standards. At some hospitals, risk identification, risk evaluation, and risk estimation, as well as risk treatment, are unstructured without any specified approach or methodology. There is no significant structured approach to risk management at the studied hospitals. Information security risk management is not followed by Iran's hospitals and their information security policies. This problem can cause a large number of challenges for their CHIS security in future. Therefore, Iran's Ministry of Health should develop practical policies to improve information security risk management in the hospitals of Iran.

  9. A Computerized Tomography Study of Vocal Tract Setting in Hyperfunctional Dysphonia and in Belting.

    Science.gov (United States)

    Saldias, Marcelo; Guzman, Marco; Miranda, Gonzalo; Laukkanen, Anne-Maria

    2018-04-03

    Vocal tract setting in hyperfunctional patients is characterized by a high larynx and narrowing of the epilaryngeal and pharyngeal region. Similar observations have been made for various singing styles, eg, belting. The voice quality in belting has been described to be loud, speech like, and high pitched. It is also often described as sounding "pressed" or "tense". The above mentioned has led to the hypothesis that belting may be strenuous to the vocal folds. However, singers and teachers of belting do not regard belting as particularly strenuous. This study investigates possible similarities and differences between hyperfunctional voice production and belting. This study concerns vocal tract setting. Four male patients with hyperfunctional dysphonia and one male contemporary commercial music singer were registered with computerized tomography while phonating on [a:] in their habitual speaking pitch. Additionally, the singer used the pitch G4 in belting. The scannings were studied in sagittal and transversal dimensions by measuring lengths, widths, and areas. Various similarities were found between belting and hyperfunction: high vertical larynx position, small hypopharyngeal width, and epilaryngeal outlet. On the other hand, belting differed from dysphonia (in addition to higher pitch) by a wider lip and jaw opening, and larger volumes of the oral cavity. Belting takes advantage of "megaphone shape" of the vocal tract. Future studies should focus on modeling and simulation to address sound energy transfer. Also, they should consider aerodynamic variables and vocal fold vibration to evaluate the "price of decibels" in these phonation types. Copyright © 2018. Published by Elsevier Inc.

  10. Information security risk management for computerized health information systems in hospitals: a case study of Iran

    Science.gov (United States)

    Zarei, Javad; Sadoughi, Farahnaz

    2016-01-01

    Background In recent years, hospitals in Iran – similar to those in other countries – have experienced growing use of computerized health information systems (CHISs), which play a significant role in the operations of hospitals. But, the major challenge of CHIS use is information security. This study attempts to evaluate CHIS information security risk management at hospitals of Iran. Materials and methods This applied study is a descriptive and cross-sectional research that has been conducted in 2015. The data were collected from 551 hospitals of Iran. Based on literature review, experts’ opinion, and observations at five hospitals, our intensive questionnaire was designed to assess security risk management for CHISs at the concerned hospitals, which was then sent to all hospitals in Iran by the Ministry of Health. Results Sixty-nine percent of the studied hospitals pursue information security policies and procedures in conformity with Iran Hospitals Accreditation Standards. At some hospitals, risk identification, risk evaluation, and risk estimation, as well as risk treatment, are unstructured without any specified approach or methodology. There is no significant structured approach to risk management at the studied hospitals. Conclusion Information security risk management is not followed by Iran’s hospitals and their information security policies. This problem can cause a large number of challenges for their CHIS security in future. Therefore, Iran’s Ministry of Health should develop practical policies to improve information security risk management in the hospitals of Iran. PMID:27313481

  11. Tomographic apparatus and method for reconstructing planar slices from non-absorbed and non-scattered radiation

    International Nuclear Information System (INIS)

    1980-01-01

    An apparatus is described which can be used in computerized tomographic systems for constructing a representation of an object and which uses a fan-shaped beam source, detectors and a convolution method of data reconstruction. (U.K.)

  12. Computed tomographic features of apical infection of equine maxillary cheek teeth: a retrospective study of 49 horses.

    Science.gov (United States)

    Bühler, M; Fürst, A; Lewis, F I; Kummer, M; Ohlerth, S

    2014-07-01

    Computed tomographic (CT) studies evaluating the relevance of individual CT features of apical infection in maxillary cheek teeth are lacking. To study the prevalence and relationship of single CT features in horses with and without clinical evidence of apical infection in maxillary cheek teeth. Retrospective case-control study. Multislice CT scans of the head of 49 horses were evaluated retrospectively. Changes of the infundibulum, pulp, root, lamina dura, periodontal space and alveolar bone in maxillary cheek teeth were recorded. Single CT changes were much more prevalent in the 28 horses with clinical signs. However, infundibular changes and a nondetectable lamina dura were also common in the 21 horses without clinical evidence of apical infection. Computed tomographic abnormalities of the pulp, root, periapical bone and periodontal space and the presence of a tooth fracture were significantly related. Infundibular changes were not associated with other CT signs of apical infection. Although nondetectable lamina dura was the most frequent CT change in all teeth in both studied groups, it was most commonly a solitary feature in otherwise normal teeth. Apical infections, defined as ≥3 CT changes, occurred mainly in the 108/208, 109/209 and 110/210 (Triadan numbers) and were found only in horses with clinical evidence of apical infection, except in one horse without clinical signs that had one affected root. Combined CT changes of the pulp, root, lamina dura, periapical bone and periodontal space and the presence of a tooth fracture appear to be reliable features to diagnose apical infection in maxillary cheek teeth. As a solitary feature, a nondetectable lamina dura should be interpreted cautiously and may even be considered normal due to its minor thickness and/or too low resolution of the imaging modality. © 2013 EVJ Ltd.

  13. Computerized cognitive training in prostate cancer patients on androgen deprivation therapy: a pilot study.

    Science.gov (United States)

    Wu, Lisa M; Amidi, Ali; Tanenbaum, Molly L; Winkel, Gary; Gordon, Wayne A; Hall, Simon J; Bovbjerg, Katrin; Diefenbach, Michael A

    2018-06-01

    Prostate cancer patients who have undergone androgen deprivation therapy (ADT) may experience cognitive impairment, yet there is an unmet need for nonpharmacological interventions to address cognitive impairment in this population. This study examines the feasibility, acceptability, and preliminary efficacy of a home-based computerized cognitive training (CCT) program to treat cancer-related cognitive impairment. Sixty men who had received ≥ 3 months of ADT were screened for at least mild cognitive or neurobehavioral impairment and randomized to 8 weeks of CCT or usual care. Follow-up assessments occurred immediately post-intervention or equivalent (T2) and 8 weeks later (T3). The acceptability of CCT was also assessed. Feasibility:A priori feasibility thresholds were partially met (i.e., randomization rate > 50%, retention rate > 70% excluding CCT drop-outs, but cognitive functioning, neurobehavioral functioning, nor quality of life. This study provides tentative support for the feasibility and acceptability of CCT to treat mild cognitive impairment in ADT patients. CCT had a beneficial effect on reaction time, but temporarily suppressed memory. CCT's benefits may be limited to a narrow area of functioning. Larger-scale studies are needed.

  14. Computerized micrographics in processing hard-copy records for an epidemiologic study

    International Nuclear Information System (INIS)

    Robie, D.M.; Fry, S.A.

    1983-01-01

    The availability of computers with increasing capabilities has made feasibile epidemiologic studies involving large populations such as those utilized to evaluate the health effects of occupational exposure to radiation. However, the storage and retrieval of data from the large numbers of hard-copy personnel, health physics, employment medical, historical or anecdotal documents that are the bases of such studies pose major logistics problems to investigators. The potential value of such records to epidemiologic studies depends, not only on their accuracy and completeness, but also on ease of accessibility. To address the latter problem, we are using a stand-alone user-oriented electronic filing system that records, stores, and secures hard-copy documents micrographically. This system is controlled by a computer that provides retrieval of a document image and printed copy (if desired) in less than 30 seconds from a maximum of eight fields. One thousand documents are randomly filmed and indexed on computer storage diskettes in two hours. Manual sorting and filing of the same number of documents takes over a day. At present two thousand documents can be recorded on each microfilm roll and 85,000 documents indexed on each diskette. Simultaneous searching for documents can be done using up to ten terminals while indexing is being done at the main terminal. The micrographics system provides the space-saving and security advantages of microfilm with the speed of computerized data retrieval

  15. Banking on Fatherhood: Pilot Studies of a Computerized Educational Tool on Sperm Banking before Cancer Treatment

    Science.gov (United States)

    Huyghe, Eric; Martinetti, Paul; Sui, Dawen; Schover, Leslie R.

    2011-01-01

    OBJECTIVES We conducted pilot studies of the feasibility and efficacy of an interactive, computerized educational tool, Banking on Fatherhood (BOF METHODS Two small randomized trials were conducted, with 20 male cancer patients eligible to bank sperm in Study 1 and 19 oncology fellows or residents in Study 2. In each trial, half of subjects viewed BOF before completing questionnaires, and half viewed it afterwards. Outcome measures included a knowledge test in both trials and a decisional conflict scale in the patient trial. All participants, plus a panel of ten experts, ultimately viewed BOF and completed a form evaluating its usability and value. RESULTS Patients who completed questionnaires after viewing BOF had significantly less decisional conflict about banking sperm than those who had not viewed it(P = 0.0065), but knowledge scores were not significantly different between groups. Physicians who filled out questionnaires after viewing BOF scored significantly higher on the Knowledge Test (P banking. Research with larger groups is needed to validate its effectiveness. PMID:19061198

  16. Computerized study with /sup 201/Tl of the cold thyroid node

    Energy Technology Data Exchange (ETDEWEB)

    Palermo, F.; Saitta, B.; Coghetto, F.; Tiberio, M.; Caldato, L.

    1982-02-01

    Because of its physical and potassium-metabolic characteristics /sup 201/Tl is more suitable than /sup 131/Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behaviour for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 ..mu..Ci/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential /sup 201/Tl uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different /sup 201/Tl kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular dissappearance-index.

  17. Computerized study with 201T1 of the cold thyroid node.

    Science.gov (United States)

    Palermo, F; Saitta, B; Coghetto, F; Tiberio, M; Caldato, L

    1982-02-01

    Because of its physical and potassium-metabolic characteristics 201T1 is more suitable than 131Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behavior for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 microCi/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential 201T1 uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different 201T1 kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular disappearance-index.

  18. Basilar expansion of the human sphenoidal sinus: an integrated anatomical and computerized tomography study

    International Nuclear Information System (INIS)

    Haetinger, Rainer G.; Navarro, Joao A.C.; Liberti, Edson A.

    2006-01-01

    Basilar expansion of the sphenoidal sinus (BESS) was studied in order to demonstrate its critical relevance in endoscopic or microscopic endonasal surgical interventions, including access to the sphenoidal sinus itself or in transsphenoidal pituitary approaches. Direct evaluation of anatomical specimens (25 dry skulls and 25 formalin-fixed hemi heads) and the use of computerized tomography (CT) (50 dry skulls and 750 patients) showed a high BESS frequency (69%). The authors considered BESS to be critical when the posterior wall of the clivus was 2-mm thick and found a high incidence of this important anatomical variation (44%). This study also evaluated the relationship between the sinonasal septa, the clivus, and the internal carotid arteries, and a considerable regularity in the location of these structures was seen. The septa were anatomically related to the internal carotid arteries in 55% and to the clivus in 33% of the cases. In conclusion, the high frequency of critical BESS here described is relevant to endoscopic or microscopic endonasal surgical interventions, including access to the sphenoidal sinus itself or in transsphenoidal pituitary approaches. (orig.)

  19. Transient ischemic attacks with and without a relevant infarct on computed tomographic scans cannot be distinguished clinically. Dutch Transient Ischemic Attack Study Group

    NARCIS (Netherlands)

    Koudstaal, P. J.; van Gijn, J.; Lodder, J.; Frenken, W. G.; Vermeulen, M.; Franke, C. L.; Hijdra, A.; Bulens, C.

    1991-01-01

    We prospectively studied clinical and computed tomographic (CT) scan findings in 79 patients with a transient ischemic attack (TIA) and a relevant cerebral infarction on CT, also known as cerebral infarction with transient signs (CITS). We compared the results with those of 527 concurrent patients

  20. Pathogenesis of traumatic intracerebral hematoma with a sequential study of computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ohmori, H; Miyazaki, S; Munekata, K; Fukushima, H [Hitachi General Hospital, Hitachi, Ibaraki (Japan); Shohji, A

    1981-04-01

    A sequential study with computerized tomography (CT scan) of two cases of traumatic intracerebral hematoma is reported. Case 1 was a 69-year-old man who had a head injury. The initial CT scan, taken 1 hour after his injury, showed a left temporal salt-and-pepper appearance, which proved to be a cerebral contusion. The CT scan 4.5 hours after his injury showed a left temporal high density area instead. An operation was performed, and a massive intracerebral hematoma was observed. Case 2 was a 61-year-old man who was also admitted because of a head injury. The initial CT scan, taken 1 hour after his injury, revealed several bifrontal intracerebral hemorrhagic spots in the low-density areas, suggesting contusion. A secondary CT scan (23 hours) demonstrated that the traumatic intracerebral hematoma had developed into a posttraumatic cerebral contusion. The operation disclosed a hematoma surrounded by contusion. These cases prove that traumatic intracerebral hematoma is often caused by cerebral contusion.

  1. Clinical and computerized evaluation in study of temporo-mandibular joint intracapsular disease.

    Science.gov (United States)

    Ciavarella, D; Mastrovincenzo, M; Sabatucci, A; Parziale, V; Granatelli, F; Violante, F; Bossù, M; Lo Muzio, L; Chimenti, C

    2010-03-01

    In this work authors show a diagnostic criteria in study of TMID: neuro occlusal clinical evaluation (NOE), T-Scan 2 system and surface electromyography (sEMG). Nine patients 25-30 years old with TMID problem and 9 healthy group control have been selected and examined. On each patients it has been performed NOE, T-Scan and sEMG test. NOE has been calculated on each patient photos lateral mandibular excursion angle called: masticatory functional angle (AFM). T-Scan System is a computerized occlusal analyzer that provide in-depth understanding of the overall balance of the occlusion. At the same time of T-Scan record sEMG tests, in resting position and in maximum clench, have been performed. In healthy control there were no AFM difference. In no healthy group there were difference between the two AFM greater than 6 degrees. T-Scan COF showed how in healthy group control there was never a difference of COF greater than 5%. In no healthy group the difference were greater than 5% Pjoint sound than the balance side P<0.001. sEMG show how in TMID patients maximum masseter activation is always lower than maximum masseter activation of healthy subjects P<0.001. Neuro occlusal clinical evaluation (NOE) in TMID patients is supported by instrumental evaluation.

  2. On the pathogenesis of traumatic intracerebral hematoma with a sequential study of computerized tomography

    International Nuclear Information System (INIS)

    Ohmori, Hidetoshi; Miyazaki, Shinichiro; Munekata, Katsuharu; Fukushima, Hiromi; Shohji, Akira.

    1981-01-01

    A sequential study with computerized tomography (CT scan) of two cases of traumatic intracerebral hematoma is reported. Case 1 was a 69-year-old man who had a head injury. The initial CT scan, taken 1 hour after his injury, showed a left temporal salt-and-pepper appearance, which proved to be a cerebral contusion. The CT scan 4.5 hours after his injury showed a left temporal high density area instead. An operation was performed, and a massive intracerebral hematoma was observed. Case 2 was a 61-year-old man who was also admitted because of a head injury. The initial CT scan, taken 1 hour after his injury, revealed several bifrontal intracerebral hemorrhagic spots in the low-density areas, suggesting contusion. A secondary CT scan (23 hours) demonstrated that the traumatic intracerebral hematoma had developed into a posttraumatic cerebral contusion. The operation disclosed a hematoma surrounded by contusion. These cases prove that traumatic intracerebral hematoma is often caused by cerebral contusion. (author)

  3. Moving image analysis to the cloud: A case study with a genome-scale tomographic study

    Energy Technology Data Exchange (ETDEWEB)

    Mader, Kevin [4Quant Ltd., Switzerland & Institute for Biomedical Engineering at University and ETH Zurich (Switzerland); Stampanoni, Marco [Institute for Biomedical Engineering at University and ETH Zurich, Switzerland & Swiss Light Source at Paul Scherrer Institut, Villigen (Switzerland)

    2016-01-28

    Over the last decade, the time required to measure a terabyte of microscopic imaging data has gone from years to minutes. This shift has moved many of the challenges away from experimental design and measurement to scalable storage, organization, and analysis. As many scientists and scientific institutions lack training and competencies in these areas, major bottlenecks have arisen and led to substantial delays and gaps between measurement, understanding, and dissemination. We present in this paper a framework for analyzing large 3D datasets using cloud-based computational and storage resources. We demonstrate its applicability by showing the setup and costs associated with the analysis of a genome-scale study of bone microstructure. We then evaluate the relative advantages and disadvantages associated with local versus cloud infrastructures.

  4. Moving image analysis to the cloud: A case study with a genome-scale tomographic study

    International Nuclear Information System (INIS)

    Mader, Kevin; Stampanoni, Marco

    2016-01-01

    Over the last decade, the time required to measure a terabyte of microscopic imaging data has gone from years to minutes. This shift has moved many of the challenges away from experimental design and measurement to scalable storage, organization, and analysis. As many scientists and scientific institutions lack training and competencies in these areas, major bottlenecks have arisen and led to substantial delays and gaps between measurement, understanding, and dissemination. We present in this paper a framework for analyzing large 3D datasets using cloud-based computational and storage resources. We demonstrate its applicability by showing the setup and costs associated with the analysis of a genome-scale study of bone microstructure. We then evaluate the relative advantages and disadvantages associated with local versus cloud infrastructures

  5. Executive Function Computerized Training in Very Preterm-Born Children: A Pilot Study.

    Science.gov (United States)

    Aarnoudse-Moens, Cornelieke S H; Twilhaar, E Sabrina; Oosterlaan, Jaap; van Veen, Heske G; Prins, Pier J M; van Kaam, Anton H L C; van Wassenaer-Leemhuis, Aleid G

    2018-06-01

    Attention problems are one of the most pronounced and documented consequences of very preterm birth (gestational age ≤32 weeks). However, up to now, there is no research published on suitable interventions at school age aimed to overcome these problems. Research in this population did show that executive functions (EFs) are strongly associated with inattention. BrainGame Brian is a newly developed computerized training, in which, in 25 training sessions, the core EFs, including working memory, impulse control, and cognitive flexibility, are trained. This pilot study aimed to examine the feasibility of studying BrainGame Brian in very preterm-born children with attention problems. Pilot feasibility intervention study with one baseline and one follow-up assessment. Feasibility was measured by the participation rate, dropout rate, and user experiences with regard to effort, training characteristics, and recommendation to others. From a larger cohort study, 15 very preterm-born children at age 10 years with parent-reported attention problems on the Child Behavior Checklist/6-18 years were invited to participate in this pilot study. BrainGame Brian was performed for a period of 6 weeks. Training outcome measures included visual working memory, impulse control, cognitive flexibility, speed variability, and parent-rated attention, for which pre- and post-training differences were examined at the group level by the Wilcoxon signed-rank test as well as for each individual child separately by the reliable change index. Twelve of 15 children and their parents agreed to participate and 11 children successfully completed BrainGame Brian in the 6-week period. Parents were positive about training characteristics and lack of interference with schooling, but scored the effort as high. We found clinically significant changes in visual working memory and speed variability in post-training assessments. BrainGame Brian is a feasible intervention for very preterm-born children with

  6. Intraosseous anesthesia with solution injection controlled by a computerized system versus conventional oral anesthesia: A preliminary study

    OpenAIRE

    Beneito-Brotons, Rut; Peñarrocha-Oltra, David; Ata-Ali, Javier; Peñarrocha, María

    2011-01-01

    Objective: To compare a computerized intraosseous anesthesia system with the conventional oral anesthesia techniques, and analyze the latency and duration of the anesthetic effect and patient preference. Design: A simple-blind prospective study was made between March 2007 and May 2008. Each patient was subjected to two anesthetic techniques: conventional and intraosseous using the Quicksleeper® system (DHT, Cholet, France). A split-mouth design was adopted in which each patient underwent trea...

  7. Advances in tomographic PIV

    NARCIS (Netherlands)

    Novara, M.

    2013-01-01

    This research deals with advanced developments in 3D particle image velocimetry based on the tomographic PIV technique (Tomo-PIV). The latter is a relatively recent measurement technique introduced by Elsinga et al. in 2005, which is based on the tomographic reconstruction of particle tracers in

  8. Lessons learned from implementation of computerized provider order entry in 5 community hospitals: a qualitative study.

    Science.gov (United States)

    Simon, Steven R; Keohane, Carol A; Amato, Mary; Coffey, Michael; Cadet, Bismarck; Zimlichman, Eyal; Bates, David W

    2013-06-24

    Computerized Provider Order Entry (CPOE) can improve patient safety, quality and efficiency, but hospitals face a host of barriers to adopting CPOE, ranging from resistance among physicians to the cost of the systems. In response to the incentives for meaningful use of health information technology and other market forces, hospitals in the United States are increasingly moving toward the adoption of CPOE. The purpose of this study was to characterize the experiences of hospitals that have successfully implemented CPOE. We used a qualitative approach to observe clinical activities and capture the experiences of physicians, nurses, pharmacists and administrators at five community hospitals in Massachusetts (USA) that adopted CPOE in the past few years. We conducted formal, structured observations of care processes in diverse inpatient settings within each of the hospitals and completed in-depth, semi-structured interviews with clinicians and staff by telephone. After transcribing the audiorecorded interviews, we analyzed the content of the transcripts iteratively, guided by principles of the Immersion and Crystallization analytic approach. Our objective was to identify attitudes, behaviors and experiences that would constitute useful lessons for other hospitals embarking on CPOE implementation. Analysis of observations and interviews resulted in findings about the CPOE implementation process in five domains: governance, preparation, support, perceptions and consequences. Successful institutions implemented clear organizational decision-making mechanisms that involved clinicians (governance). They anticipated the need for education and training of a wide range of users (preparation). These hospitals deployed ample human resources for live, in-person training and support during implementation. Successful implementation hinged on the ability of clinical leaders to address and manage perceptions and the fear of change. Implementation proceeded smoothly when institutions

  9. Bacillus subtilis Biofilm Development – A Computerized Study of Morphology and Kinetics

    Directory of Open Access Journals (Sweden)

    Sarah Gingichashvili

    2017-11-01

    Full Text Available Biofilm is commonly defined as accumulation of microbes, embedded in a self-secreted extra-cellular matrix, on solid surfaces or liquid interfaces. In this study, we analyze several aspects of Bacillus subtilis biofilm formation using tools from the field of image processing. Specifically, we characterize the growth kinetics and morphological features of B. subtilis colony type biofilm formation and compare these in colonies grown on two different types of solid media. Additionally, we propose a model for assessing B. subtilis biofilm complexity across different growth conditions. GFP-labeled B. subtilis cells were cultured on agar surfaces over a 4-day period during which microscopic images of developing colonies were taken at equal time intervals. The images were used to perform a computerized analysis of few aspects of biofilm development, based on features that characterize the different phenotypes of B. subtilis colonies. Specifically, the analysis focused on the segmented structure of the colonies, consisting of two different regions of sub-populations that comprise the biofilm – a central “core” region and an “expanding” region surrounding it. Our results demonstrate that complex biofilm of B. subtillis grown on biofilm-promoting medium [standard lysogeny broth (LB supplemented with manganese and glycerol] is characterized by rapidly developing three-dimensional complex structure observed at its core compared to biofilm grown on standard LB. As the biofilm develops, the core size remains largely unchanged during development and colony expansion is mostly attributed to the expansion in area of outer cell sub-populations. Moreover, when comparing the bacterial growth on biofilm-promoting agar to that of colonies grown on LB, we found a significant decrease in the GFP production of colonies that formed a more complex biofilm. This suggests that complex biofilm formation has a diminishing effect on cell populations at the biofilm

  10. Computer-aided design evaluation of harvestable mandibular bone volume: a clinical and tomographic human study.

    Science.gov (United States)

    Verdugo, Fernando; Simonian, Krikor; Raffaelli, Luca; D'Addona, Antonio

    2014-06-01

    To evaluate and compare the volume of bone graft material that can be safely harvested from the mandibular symphysis and rami using a computer-aided design (CAD) software program. Preoperative computerized tomography scans from 40 patients undergoing bone augmentation procedures were analyzed. Symphysis and rami cross sections were mapped using a CAD software program (AutoCAD(®), Autodesk, Inc., San Rafael, CA, USA) to evaluate the bone volume that can be safely harvested. CAD calculations were contrasted to intrasurgical measurements in a subgroup of 20 individuals. CAD calculations yielded a safe harvestable osseous volume of 1.44 cm(3) ± 0.49 for the symphysis and 0.82 cm(3) ± 0.21 for each ramus (p < .0001, confidence interval [CI] 95%: 0.47-0.78). These measurements were significantly lower (p < .0001) than the bone volumes harvested intrasurgically for both symphysis and ramus, respectively (2.40 cm(3) ± 0.50 vs. 2.65 cm(3) ± 0.45). CAD calculations of harvestable symphysis and ramus bone translated into an average of 2.40 cm(3) ± 0.50 (range: 1.80-3.10 cm(3)) and 2.65 cm(3) ± 0.45 (range: 1.90-3.50) of particulate bone graft intrasurgically, respectively. Ramus cortical was significantly thicker than the symphysis cortical, 2.9 ± 0.4 mm versus 2.19 mm ± 0.4 mm (p < .0001, CI 95%: 0.45-1.03). The symphysis and rami are good harvesting sources to obtain dense corticocancellous bone. The significant volumetric CAD differences between the symphysis and ramus seem to balance out intrasurgically and may be due to the greater cortical bone volume at the ramus area. It is plausible to harvest an average of 7.70 cm(3) from the symphysis and rami alone. The use of a CAD software program can enhance surgical treatment planning prior to bone transplantation. © 2012 Wiley Periodicals, Inc.

  11. Analysis of internal and external validity criteria for a computerized visual search task: A pilot study.

    Science.gov (United States)

    Richard's, María M; Introzzi, Isabel; Zamora, Eliana; Vernucci, Santiago

    2017-01-01

    Inhibition is one of the main executive functions, because of its fundamental role in cognitive and social development. Given the importance of reliable and computerized measurements to assessment inhibitory performance, this research intends to analyze the internal and external criteria of validity of a computerized conjunction search task, to evaluate the role of perceptual inhibition. A sample of 41 children (21 females and 20 males), aged between 6 and 11 years old (M = 8.49, SD = 1.47), intentionally selected from a private management school of Mar del Plata (Argentina), middle socio-economic level were assessed. The Conjunction Search Task from the TAC Battery, Coding and Symbol Search tasks from Wechsler Intelligence Scale for Children were used. Overall, results allow us to confirm that the perceptual inhibition task form TAC presents solid rates of internal and external validity that make a valid measurement instrument of this process.

  12. Dose profile study on computerized tomography scanning of skull with simulator object

    International Nuclear Information System (INIS)

    Mourao, A.P.

    2011-01-01

    This work presents a comparison among the dose profiles in scanning of computerized tomography of a simulator object of PMMA in its periphery region. To obtain the deposited dose at the PMMA thermoluminescent dosemeters were used positioned at the interior of PMMA simulated object longitudinal to periphery and at the center of cylinder (positions denominated North, South, East, West and Center). Eight scanning were performed of simulator object using the routine protocol for skull in eight different services of radiodiagnostic by TC

  13. Computerized Diagnostic Assistant for the Automatic Detection of Pneumothorax on Ultrasound: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Shane M. Summers, MD, RDMS

    2016-03-01

    Full Text Available Introduction: Bedside thoracic ultrasound (US can rapidly diagnose pneumothorax (PTX with improved accuracy over the physical examination and without the need for chest radiography (CXR; however, US is highly operator dependent. A computerized diagnostic assistant was developed by the United States Army Institute of Surgical Research to detect PTX on standard thoracic US images. This computer algorithm is designed to automatically detect sonographic signs of PTX by systematically analyzing B-mode US video clips for pleural sliding and M-mode still images for the seashore sign. This was a pilot study to estimate the diagnostic accuracy of the PTX detection computer algorithm when compared to an expert panel of US trained physicians. Methods: This was a retrospective study using archived thoracic US obtained on adult patients presenting to the emergency department (ED between 5/23/2011 and 8/6/2014. Emergency medicine residents, fellows, attending physicians, physician assistants, and medical students performed the US examinations and stored the images in the picture archive and communications system (PACS. The PACS was queried for all ED bedside US examinations with reported positive PTX during the study period along with a random sample of negatives. The computer algorithm then interpreted the images, and we compared the results to an independent, blinded expert panel of three physicians, each with experience reviewing over 10,000 US examinations. Results: Query of the PACS system revealed 146 bedside thoracic US examinations for analysis. Thirteen examinations were indeterminate and were excluded. There were 79 true negatives, 33 true positives, 9 false negatives, and 12 false positives. The test characteristics of the algorithm when compared to the expert panel were sensitivity 79% (95 % CI [63-89] and specificity 87% (95% CI [77-93]. For the 20 images scored as highest quality by the expert panel, the algorithm demonstrated 100% sensitivity

  14. How to Train an Injured Brain? A Pilot Feasibility Study of Home-Based Computerized Cognitive Training.

    Science.gov (United States)

    Verhelst, Helena; Vander Linden, Catharine; Vingerhoets, Guy; Caeyenberghs, Karen

    2017-02-01

    Computerized cognitive training programs have previously shown to be effective in improving cognitive abilities in patients suffering from traumatic brain injury (TBI). These studies often focused on a single cognitive function or required expensive hardware, making it difficult to be used in a home-based environment. This pilot feasibility study aimed to evaluate the feasibility of a newly developed, home-based, computerized cognitive training program for adolescents who suffered from TBI. Additionally, feasibility of study design, procedures, and measurements were examined. Case series, longitudinal, pilot, feasibility intervention study with one baseline and two follow-up assessments. Nine feasibility outcome measures and criteria for success were defined, including accessibility, training motivation/user experience, technical smoothness, training compliance, participation willingness, participation rates, loss to follow-up, assessment timescale, and assessment procedures. Five adolescent patients (four boys, mean age = 16 years 7 months, standard deviation = 9 months) with moderate to severe TBI in the chronic stage were recruited and received 8 weeks of cognitive training with BrainGames. Effect sizes (Cohen's d) were calculated to determine possible training-related effects. The new cognitive training intervention, BrainGames, and study design and procedures proved to be feasible; all nine feasibility outcome criteria were met during this pilot feasibility study. Estimates of effect sizes showed small to very large effects on cognitive measures and questionnaires, which were retained after 6 months. Our pilot study shows that a longitudinal intervention study comprising our novel, computerized cognitive training program and two follow-up assessments is feasible in adolescents suffering from TBI in the chronic stage. Future studies with larger sample sizes will evaluate training-related effects on cognitive functions and underlying brain structures.

  15. Detectability of Middle Mesial Root Canal Orifices by Troughing Technique in Mandibular Molars: A Micro-computed Tomographic Study.

    Science.gov (United States)

    Keleş, Ali; Keskin, Cangül

    2017-08-01

    The objective of the present study was to measure the orifice depth of middle mesial canals (MMCs) and evaluate the detectability of orifices using troughing preparation. For this study, 85 mandibular molar teeth with MMCs were selected from the scanned micro-computed tomographic images. The MMCs were categorized, and the distances between the MMC orifices and the cementoenamel junctions (CEJ) were recorded as the depth of the orifice. Data were evaluated with frequency analysis and a chi-square test using SPSS (SPSS Inc, Chicago, IL), and the results indicated a 5% significance level. It was found that 77.41% of the MMC orifices were at the CEJ level, whereas 5.38% and 9.69% of the MMC orifices were detectable within 1-mm and 2-mm depths from the CEJ, respectively. Of the specimens, 7.52% had MMC orifices deeper than 2 mm from the CEJ. Confluent anatomy was the most frequent configuration. No significant relation was detected between the orifice depth and MMC configuration (P > .05). It was concluded that 77.41% of the specimens did not require troughing preparation, the remaining 15.07% would require troughing, and 7.52% could not be accessed even with the troughing preparation. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Health physics aspects of the EMI computerized tomography brain scanner

    International Nuclear Information System (INIS)

    Villafana, T.; Scouras, J.; Kirkland, L.; McElroy, N.; Paras, P.

    1978-01-01

    The EMI computerized tomographic cranial scanner is one of the first radiological systems incorporating an on-line computer. The result is an increase in the ability to visualize such tissues as grey matter and white matter as well as blood pools and tumor volumes. This advance has already begun to revolutionize radiological practice. Because of the totally different configuration of this unit, concern has been expressed over the dosages received by the patient, consequently the health physics aspects of this unit have been studied. Specifically, doses received by the surface of head and interior brain points as well as by the lens of the eye and gonads are reported here. X-ray output, beam half-value layers and barrier shielding requirements are also reported and discussed. (author)

  17. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  18. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  19. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  20. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  1. Deviations of Mesial Root Canals of Mandibular First Molar Teeth at the Apical Third: A Micro-computed Tomographic Study.

    Science.gov (United States)

    Keles, Ali; Keskin, Cangül

    2018-04-19

    The present study aimed to quantitatively analyze apical foramen deviations of mesial root canals of mandibular first molar teeth by means of micro-computed tomographic (micro-CT) imaging. Micro-CT images of the mesial roots of 109 mandibular first molar teeth with independent mesiobuccal (MB) and mesiolingual (ML) root canals were analyzed. The deviations of the apical foramina of the MB, ML, and middle mesial root canals from the anatomic apex were measured. The vertical distance between the apical foramina of each mesial root canal in relation to each other was also calculated. The distances from the apical foramina of the MB, ML, and middle mesial root canals to the anatomic apex of the mesial root were up to 2.51 mm, 3.21 mm, and 5.67 mm, respectively. There was no significant difference between the deviations of MB and ML root canals from each other (P > .05). The middle mesial root canal showed the greatest deviation compared with the MB and ML canals (P < .05). The apical foramina of mesial root canals of mandibular first molar teeth showed greater variations from each other and anatomic apices than previously reported. Clinically, the use of electronic apex locators for the detection of minor apical foramen of each mesial root canal is of the utmost important. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Combining operando synchrotron X-ray tomographic microscopy and scanning X-ray diffraction to study lithium ion batteries

    Science.gov (United States)

    Pietsch, Patrick; Hess, Michael; Ludwig, Wolfgang; Eller, Jens; Wood, Vanessa

    2016-06-01

    We present an operando study of a lithium ion battery combining scanning X-ray diffraction (SXRD) and synchrotron radiation X-ray tomographic microscopy (SRXTM) simultaneously for the first time. This combination of techniques facilitates the investigation of dynamic processes in lithium ion batteries containing amorphous and/or weakly attenuating active materials. While amorphous materials pose a challenge for diffraction techniques, weakly attenuating material systems pose a challenge for attenuation-contrast tomography. Furthermore, combining SXRD and SRXTM can be used to correlate processes occurring at the atomic level in the crystal lattices of the active materials with those at the scale of electrode microstructure. To demonstrate the benefits of this approach, we investigate a silicon powder electrode in lithium metal half-cell configuration. Combining SXRD and SRXTM, we are able to (i) quantify the dissolution of the metallic lithium electrode and the expansion of the silicon electrode, (ii) better understand the formation of the Li15Si4 phase, and (iii) non-invasively probe kinetic limitations within the silicon electrode. A simple model based on the 1D diffusion equation allows us to qualitatively understand the observed kinetics and demonstrates why high-capacity electrodes are more prone to inhomogeneous lithiation reactions.

  3. Combining operando synchrotron X-ray tomographic microscopy and scanning X-ray diffraction to study lithium ion batteries

    Science.gov (United States)

    Pietsch, Patrick; Hess, Michael; Ludwig, Wolfgang; Eller, Jens; Wood, Vanessa

    2016-01-01

    We present an operando study of a lithium ion battery combining scanning X-ray diffraction (SXRD) and synchrotron radiation X-ray tomographic microscopy (SRXTM) simultaneously for the first time. This combination of techniques facilitates the investigation of dynamic processes in lithium ion batteries containing amorphous and/or weakly attenuating active materials. While amorphous materials pose a challenge for diffraction techniques, weakly attenuating material systems pose a challenge for attenuation-contrast tomography. Furthermore, combining SXRD and SRXTM can be used to correlate processes occurring at the atomic level in the crystal lattices of the active materials with those at the scale of electrode microstructure. To demonstrate the benefits of this approach, we investigate a silicon powder electrode in lithium metal half-cell configuration. Combining SXRD and SRXTM, we are able to (i) quantify the dissolution of the metallic lithium electrode and the expansion of the silicon electrode, (ii) better understand the formation of the Li15Si4 phase, and (iii) non-invasively probe kinetic limitations within the silicon electrode. A simple model based on the 1D diffusion equation allows us to qualitatively understand the observed kinetics and demonstrates why high-capacity electrodes are more prone to inhomogeneous lithiation reactions. PMID:27324109

  4. Comparative study of adenosine and exercise 201Tl myocardial perfusion tomographic imaging for detection of coronary heart disease

    International Nuclear Information System (INIS)

    Wang Xiong

    1997-01-01

    To compare diagnostic accuracy of adenosine and exercise 201 Tl myocardial perfusion tomographic imaging for detection of coronary heart disease (CHD) in patients with a normal rest ECG and no history of myocardial infarction, 81 patients with CHD and 10 normal control subjects underwent adenosine myocardial perfusion imaging, exercise nuclide myocardial perfusion imaging was performed in 117 patients with CHD and 16 normal control subjects, two groups also had coronary arteriography. Both exercise and adenosine testing parameters were analysed. It is shown: 1) The sensitivity and specificity for detection of CHD were 79% vs 80% for adenosine group and 81% vs 81% for exercise myocardial perfusion imaging group respectively. There was no significant difference in comparison with two matched groups (χ 2 = 1.13, χ 2 = 0.18, χ 2 = 0.12, P>0.05). 2) Side effects induced by adenosine accounted for 89% of patients, all symptoms were mild and disappeared quickly after the termination of the study except in 2 cases withdrawal of infusion needed because of severe angina pectoris. Adenosine myocardial perfusion imaging is a safe and sensitive method for detection of CHD. The diagnostic value of adenosine test is similar to that of exercise myocardial perfusion imaging and particularly useful in evaluating patients unable to perform exercise test or achieve adequate level of exercise

  5. Study and development of a high resolution tomograph for the γ radio-imagery in vivo of small animals

    International Nuclear Information System (INIS)

    Valda Ochoa, A.

    1995-01-01

    By the use of molecular radio-labelled tracers, molecular biology can reveal some aspects of the functional organisation of the brain. Non invasive in vivo brain research on small laboratory animals, like mice or rats, require analysis of structures of some cubic millimeters present in a brain of the order of a cubic centimeter. Since imaging performances of positron emission tomography (PET) and single photon emission tomography (SPECT) fail in this research field, we present here a high resolution tomograph (TOHR) based on an original principle that allows to overcome the compromise between detection efficiency and spatial resolution. TOHR is a radiation counter device having a large solid angle focusing collimator. By the use of radio-tracers decaying by a cascade of two photons, coincidence detection offers an accurate delimitation of the analysed region and improves spatial resolution. TOHR acts as a scanner, so the image is built voxel by voxel by moving the animal relative to the detector. A numerical feasibility study of such a system shows that a sub millimeter spatial resolution can be achieved. We show that the chemical etching technique is well suited for manufacturing a multi-module focusing collimator by building and testing two such modules. Finally a numerical simulation exhibits TOHR's performance in a neuro-pharmacological experiment on a rat. From these results, other application of TOHR are envisaged, such as oncology (in vivo evolution of tumours) or gene therapy (distribution of viral particles in the brain). (author). 51 refs., 73 figs., 3 tabs

  6. A study on an automated computerized differential diagnosis of diffuse liver diseases, based only on hepatic scintigrams using sup(99m)Tc-Sn-colloid

    International Nuclear Information System (INIS)

    Matsuo, Michimasa; Fujii, Susumu; Kaneda, Yukio

    1980-01-01

    Hepatic scintigrams using sup(99m)Tc-compounds are now routinely performed. In this study, automated computerized pattern characterizations of right lateral hepatic scintigrams using sup(99m)Tc-Sn colloid were studied to extract characteristic indicators, which are effective for an automated computerized differential diagnosis. The program, developed by us, of the automated computerized pattern characterization and the automated computerized differential diagnosis can be performed without the aid of professional doctors' ability of pattern recognition. The right lateral hepatic scintigrams of fifty one cases, which are accurately diagnosed by biopsy, are applied as the training group. The results of the automated computerized differential diagnosis were as follows: Three cases were accurately diagnosed among 3 normal cases; Three among 3 acute hepatitis; Seven among 7 chronic inactive hepatitis; Twenty among 22 chronic active hepatitis; Sixteen among 16 liver cirrhosis. Only two cases of chronic active hepatitis are falsely-diagnosed as chronic inactive hepatitis and as liver cirrhosis respectively. The over all accuracy rate was 96% in the training group. With this result, the automated computerized differential diagnosis of diffuse liver diseases is suggested to be possible, based on the hepatic scintigram. (author)

  7. Study on beam geometry and image reconstruction algorithm in fast neutron computerized tomography at NECTAR facility

    Science.gov (United States)

    Guo, J.; Bücherl, T.; Zou, Y.; Guo, Z.

    2011-09-01

    Investigations on the fast neutron beam geometry for the NECTAR facility are presented. The results of MCNP simulations and experimental measurements of the beam distributions at NECTAR are compared. Boltzmann functions are used to describe the beam profile in the detection plane assuming the area source to be set up of large number of single neutron point sources. An iterative algebraic reconstruction algorithm is developed, realized and verified by both simulated and measured projection data. The feasibility for improved reconstruction in fast neutron computerized tomography at the NECTAR facility is demonstrated.

  8. Study on beam geometry and image reconstruction algorithm in fast neutron computerized tomography at NECTAR facility

    International Nuclear Information System (INIS)

    Guo, J.; Buecherl, T.; Zou, Y.; Guo, Z.

    2011-01-01

    Investigations on the fast neutron beam geometry for the NECTAR facility are presented. The results of MCNP simulations and experimental measurements of the beam distributions at NECTAR are compared. Boltzmann functions are used to describe the beam profile in the detection plane assuming the area source to be set up of large number of single neutron point sources. An iterative algebraic reconstruction algorithm is developed, realized and verified by both simulated and measured projection data. The feasibility for improved reconstruction in fast neutron computerized tomography at the NECTAR facility is demonstrated.

  9. Study on beam geometry and image reconstruction algorithm in fast neutron computerized tomography at NECTAR facility

    Energy Technology Data Exchange (ETDEWEB)

    Guo, J. [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China); Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, Garching 80748 (Germany); Buecherl, T. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, Garching 80748 (Germany); Zou, Y., E-mail: zouyubin@pku.edu.cn [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China); Guo, Z. [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China)

    2011-09-21

    Investigations on the fast neutron beam geometry for the NECTAR facility are presented. The results of MCNP simulations and experimental measurements of the beam distributions at NECTAR are compared. Boltzmann functions are used to describe the beam profile in the detection plane assuming the area source to be set up of large number of single neutron point sources. An iterative algebraic reconstruction algorithm is developed, realized and verified by both simulated and measured projection data. The feasibility for improved reconstruction in fast neutron computerized tomography at the NECTAR facility is demonstrated.

  10. Computerized medical convocations

    International Nuclear Information System (INIS)

    Roche, Annie; Gilbert, Jean-Francois; Chiadot, Pierre; Vanzetto, Rene; Darnault, Jean

    1969-06-01

    Thanks to a close collaboration between the Medical and Social department and the Numerical Calculation Laboratory, a computerized convocation system has been implemented to reduce the administrative workload and to introduce more rigor in medical management, patient historical background and statistics. This work comprises: - a preliminary study of the data generating medical convocations and the related practical requirements; - the programming work according to these data; - the realisation of the mechano-graphical file covering the overall personnel [fr

  11. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  12. Highly resolving computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions.

  13. A longitudinal study of computerized cognitive training in stroke patients - effects on cognitive function and white matter.

    Science.gov (United States)

    Nyberg, Claudia Kim; Nordvik, Jan Egil; Becker, Frank; Rohani, Darius A; Sederevicius, Donatas; Fjell, Anders M; Walhovd, Kristine B

    2018-05-01

    Background Computerized cognitive training is suggested to enhance attention and working memory functioning following stroke, but effects on brain and behavior are not sufficiently studied and longitudinal studies assessing brain and behavior relationships are scarce. Objective The study objectives were to investigate relations between neuropsychological performance post-stroke and white matter microstructure measures derived from diffusion tensor imaging (DTI), including changes after 6 weeks of working memory training. Methods In this experimental training study, 26 stroke patients underwent DTI and neuropsychological tests at 3 time points - before and after a passive phase of 6 weeks, and again after 6 weeks of working memory training (Cogmed QM). Fractional anisotropy (FA) was extracted from stroke-free brain areas to assess the white matter microstructure. Twenty-two participants completed the majority of training (≥18/25 sessions) and were entered into longitudinal analyses. Results Significant correlations between FA and baseline cognitive functions were observed (r = 0.58, p = 0.004), however, no evidence was found of generally improved cognitive functions following training or of changes in white matter microstructure. Conclusions While white matter microstructure related to baseline cognitive function in stroke patients, the study revealed no effect on cognitive functions or microstructural changes in white matter in relation to computerized working memory training.

  14. A study on the development of the computerized safety evaluation system of the motor operated valve

    International Nuclear Information System (INIS)

    Kim, J. C.; Park, S. G.; Lee, D. H.; Ahn, N. S.; Bae, H. J.; Hong, J. S.

    2001-01-01

    The MOVIDIK (Motor-Operated Valves Integrated Database and Information of KEPCO) system was developed to assist the design basis safety evaluation and to manage the overall data made by evaluation on the safety-related Motor-operated Valves(MOV) in the nuclear power plant. The huge amount of safety evaluation data of the MOV is being piled up as the safety evaluation work goes on. Much time and manpower was needed to do safety evaluation works without computerized system and it was not easy to obtain the statistic information from the evaluation data. The MOVIDIK will improve the efficiency of safety evaluation works and standardize the analysis process. But the some process which needs specific evaluation codes and engineering calculation by the specialists was not computerized. The MOVIDIK was developed by JAVA/JSP language known by the flexibility of language and the easiness of transplantation between operating systems. The Oracle 8i which is the world's most popular database was used for MOVIDIK database

  15. Computerized training improves verbal working memory in patients with myalgic encephalomyelitis/chronic fatigue syndrome: A pilot study.

    Science.gov (United States)

    Maroti, Daniel; Westerberg, Annika Fryxell; Saury, Jean-Michel; Bileviciute-Ljungar, Indre

    2015-08-18

    Patients with myalgic encephalomyelitis/chronic fatigue syndrome experience cognitive difficulties. The aim of this study was to evaluate the effect of computerized training on working memory in this syndrome. Non-randomized (quasi-experimental) study with no-treatment control group and non-equivalent dependent variable design in a myalgic encephalomyelitis/chronic fatigue syndrome-cohort. Patients with myalgic encephalomyelitis/chronic fatigue syndrome who participated in a 6-month outpatient rehabilitation programme were included in the study. Eleven patients who showed signs of working memory deficit were recruited for additional memory training and 12 patients with no working memory deficit served as controls. Cognitive training with computerized working memory tasks of increasing difficulty was performed 30-45 min/day, 5 days/week over a 5-week period. Short-term and working memory tests (Digit Span - forward, backward, total) were used as primary outcome measures. Nine of the 11 patients were able to complete the training. Cognitive training increased working memory (p = 0.003) and general attention (p = 0.004) to the mean level. Short-term memory was also improved, but the difference was not statistically significant (p = 0.052) vs prior training. The control group did not show any significant improvement in primary outcome measures. Cognitive training may be a new treatment for patients with myalgic encephalomyelitis/chronic fatigue syndrome.

  16. Mobile 3D tomograph

    International Nuclear Information System (INIS)

    Illerhaus, Bernhard; Goebbels, Juergen; Onel, Yener; Sauerwein, Christoph

    2008-01-01

    Mobile tomographs often have the problem that high spatial resolution is impossible owing to the position or setup of the tomograph. While the tree tomograph developed by Messrs. Isotopenforschung Dr. Sauerwein GmbH worked well in practice, it is no longer used as the spatial resolution and measuring time are insufficient for many modern applications. The paper shows that the mechanical base of the method is sufficient for 3D CT measurements with modern detectors and X-ray tubes. CT measurements with very good statistics take less than 10 min. This means that mobile systems can be used, e.g. in examinations of non-transportable cultural objects or monuments. Enhancement of the spatial resolution of mobile tomographs capable of measuring in any position is made difficult by the fact that the tomograph has moving parts and will therefore have weight shifts. With the aid of tomographies whose spatial resolution is far higher than the mechanical accuracy, a correction method is presented for direct integration of the Feldkamp algorithm [de

  17. Computerized tomographic evaluations of 37 cases of craniopharyngiomas

    International Nuclear Information System (INIS)

    Nagasawa, Shiro; Yamashita, Junkoh; Handa, Hajime; Takeuchi, Juji.

    1983-01-01

    Although craniopharyngiomas are well known to exhibit three basic CT characteristics: Calcification, cysts, and contrast enhancement (CE), several cases with atypical CT manifestations have been reported lately. These atypical manifestations can be classified into three groups: Unusual extensions of the tumors, high-density cysts, and marked homogeneous CE. The CT scans obtained in our recent series of 37 craniopharyngiomas were evaluated in an attempt to analyze the tumoral extensions, the cyst densities, and the CE, and were compared with those of other, rarer parasellar lesions. Cystic tumors were much more frequent than solid tumors (Table 1); 14 cases (38%) were exclusively cystic; 17 cases (46%), equally cystic and solid, and 6 cases (16%), solid. Calcifications were present in 86% of the children and 43% of the adults. Unusual extensions were noted in 7 cases (Fig. 1, 2): Anteriorly to the frontal fossa (5 cases, 14%), laterally to the temporal fossa (1 case, 3%), or posteriorly to the posterior fossa (1 case, 3%). All these tumors were either purely cystic or equally cystic and solid. Cystic portions were detected in the tumors of 31 cases (Table 2). Although the majority of the cystic portions (25 cases, 81%) were low in density, isodense cysts were observed in 6 cases (19%). Out of 23 cases exhibiting solid portions in the tumors, high-density areas (calcified masses) were detected in 3 cases and mixed-density areas in 20 cases. While these 20 cases all showed CE, marked homogeneous CE were noted in 5 cases (25%). (J.P.N.)

  18. Computerized tomographic evaluations of 33 consecutive cases of craniopharyngiomas

    International Nuclear Information System (INIS)

    Nagasawa, Shiro; Takeuchi, Juji; Yamashita, Junkoh; Handa, Hajime

    1983-01-01

    Although craniopharyngiomas are widely known to exhibit three basic CT characteristics; calcification, cyst(s) and contrast enhancement (CE), several cases with atypical CT manifestations have been reported lately. These atypical manifestations can be classified into unusual extensions of the tumors, high dense cyst and marked homogeneous CE. The CT scans obtained in our recent series of 33 craniopharyngiomas were evaluated to analyze tumoral extensions, cyst density and CE. Cystic tumors were much more frequent than solid tumors (Table 1); 13 cases (39%) were exclusively cystic, 15 cases (45%) equally cystic and solid, and 5 case (15%) solid. Calcifications were present in 80 % in children and 39% in adults. Unusual extensions were noted in 7 cases (Fig. 2,3,4); anteriorly to the frontal fossa (5 cases, 15 %), laterally to the temporal fossa (1 case, 3%) and posteriorly to the posterior fossa (1 case, 3%). All these tumors were either pure cystic or equally cystic and solid. Cystic portions were detected in the tumors of 28 cases (Table 2). Although the majority of the cystic portions (22 cases, 79%) were low density, iso-dense cysts were observed in 6 cases (21%). Out of 20 cases exhibiting solid portions in the tumors, high density areas (calcified masses) were detected in 3 cases and mixed density areas in 17 cases (Table 3). While these 17 cases showed CE, marked homogeneous CE were noted in 5 cases (29%)

  19. Computerized tomographic x-ray scanner system and gantry assembly

    International Nuclear Information System (INIS)

    Doyd, D.P.; Lanzara, G.

    1991-01-01

    This patent describes a scanner assembly. It comprises: a support head, a C-shaped gantry, means for supporting the gantry in the support head for rotating movement, an x-ray source mounted on one side of the gantry for independent movement with respect to a detector array along the gantry, the x-ray source projecting x-rays across the gantry, and a detector array mounted on the other side of a gantry for independent movement with respect to the x-ray source along the gantry, the detector array serving to receive the projected x-rays

  20. Computerized axil tomographic scanning in tumors of the adrenal glands

    International Nuclear Information System (INIS)

    Albertotti, C.; Figueiredo, M.A.; Clemente Filho, A.S.; Secaf, F.

    1980-01-01

    Computed tomography was used for diagnosing primary or recurrent adrenal gland tumors, being positive in all nine cases and later confirmed at surgery. The tumors are adenocarcinoma (6 cases); pheochromocytoma (2); aldostenoma (1) an cyst(u). Comparison of selective arteriography, ultrasonography, scintigraphy and computed tomography has shown the later to be most accurate. (Author) [pt

  1. Feasibility study of computerized presentation of procedures of a nuclear plant

    International Nuclear Information System (INIS)

    Takagawa, Kenichi; Niwa, Yuji; Urakami, Masahiro

    2010-01-01

    Introduction of a digital instrumentation control system is in progress in recent nuclear power plants, and an application of Computer Based Procedures (CBP) is being considered. The Institute of Nuclear Safety System, Incorporated has developed a system for a Computerized Presentation of Procedures (CPP) which corresponds to CBP. By fiscal year 2002, all items in the emergency operation procedures of a model plant were made displayable on the CPP. In 2003, the CPP instead of the paper based procedures was used for trial by the operators of a nuclear power plant in an actual training simulator, and feasibility of its practical application was evaluated. Based on the result, we considered subjects which should be taken into account in the future. As a result, improvements of CPP and its navigation system, etc. to enable operations with multi-procedures in parallel were extracted as primary subjects for introduction of CBP in the future as well as practical application of CPP. (author)

  2. A study on a systematic approach of verification and validation of a computerized procedure system: ImPRO

    International Nuclear Information System (INIS)

    Qin, Wei; Seong, Poong Hyun

    2003-01-01

    Paper Based Procedure (PBP) and Computerized Procedure System (CPS) are studied to demonstrate that it is necessary to develop CPS in NPP I and C system. Computerized procedure system is actually a software system. All the desired and undesired properties of a software system can be described and evaluated as software qualities. Generally, software qualities can be categorized into product quality and process quality. In order to achieve product quality, the process quality of a software system should also be considered and achieved. Characteristics of CPS will be described to analyse the product and process of an example CPS: ImPRO. At the same time, several main product and process issues will be analysed from Verification and Validation (V and V) point of view. It is concluded and suggested that V and V activities can also be regarded as software development process, this point of view then is applied to the V and V activities of ImPRO as a systematic approach of V and V of ImPRO. To support and realize this approach, suitable testing technologies and testing strategies are suggested

  3. Computerized system to measure interproximal alveolar bone levels in epidemiologic, radiographic investigations. II. Intra- and inter-examinar variation study

    Energy Technology Data Exchange (ETDEWEB)

    Wouters, F.R.; Frithiof, L.; Soeder, P.Oe.; Hellden, L.; Lavstedt, S.; Salonen, L.

    1988-01-01

    The study was aimed at analyzing intra- and inter-examiner variations in computerized measurement and in non-measurability of alveolar bone level in a cross-sectional, epidemiologic material. At each interproximal tooth surface, alveolar bone height in percentage of root length (B/R) and tooth length (B/T) were determined twice by one examiner and once by a second examiner from X5-magnified periapical radiographs. The overall intra- and inter-examiner variations in measurement were 2.85% and 3.84% of root length and 1.97% and 2.82% of tooth length, respectively. The varations were different for different tooth groups and for different degrees of severity of marginal periodontitis. The overall proportions on non-measurable tooth surfaces varied with examiner from 32% to 39% and from 43% to 48% of the available interproximal tooth surfaces for B/R and B/T, respectively. With regard to the level of reliability, the computerized method reported is appropriate to cross-sectional, epidemiologic investigations from radiographs.

  4. Computerized tomography in diagnosis of cerebrocranial injury

    International Nuclear Information System (INIS)

    Kornienko, V.N.; Vasin, N.Ya.; Kuz'menko, V.A.

    1987-01-01

    The method of computerized tomographical examination are presented. Th KT-characters of concussion of the brain, its contusion of different severity, compressions in case of traumatic intracranial hematomas, contusion injuries, brain edema and different aftereffects of cerebrocranial injury are given. On the basis of comparison of the data of clinical and KT examination the dynamics of intracranial traumatic injuries in the course of treatment is described. The problems of therapeutic and surgical tactics depending on the degree and form of intracranial structure injuries and the phase of clinical course of posttraumatic process are discussed

  5. Study of the tomographic image quality provided by a conical beam system kilo voltage

    International Nuclear Information System (INIS)

    Garayoa Roca, J.; Castro Tejero, P.

    2011-01-01

    Imaging systems play an increasingly important role in radiotherapy, and to ensure the quality of the process, you must know the characteristics and limitations of available imaging systems. In this study we sought to evaluate the image quality of an IGRT system based on a kilo voltage cone beam.

  6. Prediction of traumatic avascular necrosis of the femoral head by single photon emission computerized tomography and computerized tomography: an experimental study in dogs

    Directory of Open Access Journals (Sweden)

    SHEN Feng

    2012-02-01

    Full Text Available 【Abstract】 Objective: To evaluate the femoral head perfusion and to predict the traumatic avascular necrosis (AVN of the femoral head by single photon emission computerized tomography and computerized tomography (SPECT/CT. Methods: Totally 18 adult beagle dogs were divided randomly into three equal-sized (n=6 groups. Subsequently different degrees of ischemia model were developed by destroying blood vessels of the femoral head. The left hip received sham operation as normal control and the right hip underwent blood interruption. In Group A, the ligamentum teres was cut off. In Group B, the marrow cavity of the right femoral neck was destroyed while in Group C, the soft tissues at the base of the femoral neck were stripped in addition to the resection of the ligamentum teres and destruction of the marrow cavity. Three hours after surgery, SPECT/CT was performed. Laser Doppler Flowmetry (LDF measurements were also obtained at three different time points (before operation, immediately and three hours after operation in order to assess the change process of blood supply to the femoral head. Results: SPECT/CT showed no significant difference in the radionuclide uptake between the right and left femoral heads in Group A (t=-0.09, P=0.94 and Group B (t= 0.52, P=0.62. However, in Group C, it was 261±62 for the right femoral head, only 12% of that in the left femoral head. LDF measurements indicated that the femoral head perfusion was decreased from (45.0±3.3 PU to (39.1±3.7 PU in Group A, from (44.0±2.7 PU to (34.3±2.6 PU in Group B, and from (47.3±2.1 PU to (4.96±0.6 PU in Group C immediately after operation. However, the perfusion was restored and returned to normal values three hours after operation except in Group C. Conclusion: SPECT/CT could assess the perfusion of the femoral head semiquantitatively, which might be useful in predicting the development of traumatic AVN. Key words: Femur head necrosis; Femoral head; Tomography, emission

  7. X-ray tomographic techniques for the study of cultural heritages

    International Nuclear Information System (INIS)

    Schillaci, T.

    2011-01-01

    In recent years, X-ray Computed Tomography (CT) has become an important tool for investigating all kinds of materials. Due to its non-destructive nature, it is especially suitable to investigate samples that may not be altered or damaged during the course of the investigation. CT has been recently introduced in the field of Cultural Heritage diagnostics, where it can be used for the investigation of different works of art, as it preserves the integrity of the object and gives morphological and physical information on its inner structure. This paper describes a methodological approach on the use of the X-ray CT technique to study items belonging to cultural heritage with the aim to obtain information related to their preservation state and therefore, to plan an adequate conservation and restoration procedure. Significant examples of applications are the study of porosity and pore size distribution and their connectivity for different porous materials and the study of kinetics of capillary fluid absorption in sedimentary rocks. Other applications are relevant to the possibility to investigate in a non-destructive way the presence of defects or fractures inside an object and, not last in order of importance, the possibility to study different typologies of woods or waterlogged woods, the presence of an eventual biodegradation state and the possibility to perform a dendrochronology. In this paper, the results of some case studies, obtained through the integrated use of CT systems with different resolutions, are reported. Other expected future developments will be addressed to the integration of CT data with results of compatible non-destructive techniques.

  8. Tomographic visualization of stress corrosion cracks in tubing

    International Nuclear Information System (INIS)

    Morris, R.A.; Kruger, R.P.; Wecksung, G.W.

    1979-06-01

    A feasibility study was conducted to determine the possibility of detecting and sizing cracks in reactor cooling water tubes using tomographic techniques. Due to time and financial constraints, only one tomographic reconstruction using the best technique available was made. The results indicate that tomographic reconstructions can, in fact, detect cracks in the tubing and might possibly be capable of measuring the depth of the cracks. Limits of detectability and sensitivity have not been determined but should be investigated in any future work

  9. A tomographic study of positional and bony changes in the temporomandibular joint following orthognathic surgery

    International Nuclear Information System (INIS)

    Song, Nam Kyu; Kim Min Suk; Koh, Kwang Joon

    1992-01-01

    The purpose of this study was to aid in the evaluation of prognosis of temporomandibular joint following orthognathic surgery. For this study, 20 patients (40 TMJ) who undergone orthognathic surgery were examined. Preoperative and postoperative tomograms of TMJ were taken. And the subjects were divided into 3 groups according to postoperative periods. The obtained results were as follows : 1. There were no significant differences between preoperative and postoperative changes in joint spaces in each group and between groups (P<0.05). 2. There were no significant differences between preoperative and postoperative ratio of joint spaces (P<0.05).3. There were no significant differences between preoperative and postoperative changes in the range of motion of condylar head (P<0.05). 4. The bony changes of condylar head were observed in 14 (35%) condyles (6 erosion, 2 flattening, 5 double contour, 1 osteophyte).

  10. A tomographic study of positional and bony changes in the temporomandibular joint following orthognathic surgery

    Energy Technology Data Exchange (ETDEWEB)

    Song, Nam Kyu; Kim Min Suk; Koh, Kwang Joon [Dept. of Oral Radiology, College of Dentistry, Chonpook National University, Chonju (Korea, Republic of)

    1992-08-15

    The purpose of this study was to aid in the evaluation of prognosis of temporomandibular joint following orthognathic surgery. For this study, 20 patients (40 TMJ) who undergone orthognathic surgery were examined. Preoperative and postoperative tomograms of TMJ were taken. And the subjects were divided into 3 groups according to postoperative periods. The obtained results were as follows : 1. There were no significant differences between preoperative and postoperative changes in joint spaces in each group and between groups (P<0.05). 2. There were no significant differences between preoperative and postoperative ratio of joint spaces (P<0.05).3. There were no significant differences between preoperative and postoperative changes in the range of motion of condylar head (P<0.05). 4. The bony changes of condylar head were observed in 14 (35%) condyles (6 erosion, 2 flattening, 5 double contour, 1 osteophyte).

  11. Persistent foramen of Huschke: a tomographic study; Persistencia do forame de Huschke: um estudo tomografico

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Henrique Nogueira; Carvalho, Antonio Carlos Pires; Mello, Rossana Corbo Ramalho de [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia]. E-mail: hsodonto@gmail.com; Leite, Horacio Faig [UNESP, Sao Jose dos Campos, SP (Brazil). Faculdade de Odontologia; Xavier, Sergio Salles [Universidade Federal do Rio de Janeiro, RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Servico de Cardiologia

    2006-07-15

    Objective: to evaluate the persistency of foramen of Huschke by means of computed tomography study of the ear region and approaching important clinical aspects related to the presence of this anatomical anomaly. Materials and methods: two examiners have analyzed the whole tympanic portion of temporal bone in 150 bilateral computed tomography studies of the ear region, searching for foramen of Huschke presence or absence. Results: the mentioned anatomical anomaly was found in 17 cases (11.3%), 13 patients (76.5%) being female and four (23.5%) male. This higher female incidence is statistically confirmed. Conclusion: ear and/or temporomandibular joint specialists should turn their attention to the persistency of foramen of Huschke. (author)

  12. Kinetic modeling of receptor-ligand binding applied to positron emission tomographic studies with neuroleptic tracers

    Energy Technology Data Exchange (ETDEWEB)

    Logan, J; Wolf, A P; Shiue, C Y; Fowler, J S

    1987-01-01

    Positron emission tomography (PET) with labeled neuroleptics has made possible the study of neurotransmitter-receptor systems in vivo. In this study we investigate the kinetics of the 3,4-dihydroxyphenylethylamine (dopamine) receptor-ligand binding using PET data from a series of experiments in the baboon with the /sup 18/F-labeled drugs spiperone, haloperidol, and benperidol. Models used to describe these systems are based on first-order kinetics which applies at high specific activity (low receptor occupancy). The parameters governing the uptake and loss of drug from the brain were found by fitting PET data from regions with little or no receptor concentration (cerebellum) and from experiments in which specific binding was blocked by pretreatment with the drug (+)-butaclamol. Receptor constants were determined by fitting data from receptor-containing structures. Correcting the arterial plasma activities (the model driving function) for the presence of drug metabolites was found to be important in the modeling of these systems.

  13. In vivo tomographic study of cerebral blood perfusion with SPECT in hemiparkinsonian monkeys

    International Nuclear Information System (INIS)

    Chen Shengdi; Xu Delong

    1994-01-01

    The authors present data on the utility of functional brain imaging with 99m Tc-ECD and SPECT in the study of MPTP induced hemiparkinsonism in monkeys. Injection of MPTP into the right common carotid artery of 10 rhesus monkeys produced hemiparkinsonism in the contralateral limbs which responded to antiparkinsonian medication. The unilateral neurotoxicity of the MPTP treated side was confirmed biochemically by marked reduction of DA contents in the nigrostriatum and histologically by selective neuronal loss in the substantia nigra. These monkeys with hemiparkinsonism were studied with SPECT using 99m Tc-ECD as perfusion marker. The results of brain scanning showed that the cerebral blood perfusion of MPTP treated side was significantly depleted 20∼90 days after MPTP intoxication, and returned to normal 8 months after perfusion. The experiment indicates that abnormal cerebral blood perfusion is involved in the course of parkinsonian pathophysiology

  14. COMPUTED TOMOGRAPHIC APPEARANCE OF THE TEMPOROMANDIBULAR JOINT IN 1018 ASYMPTOMATIC HORSES: A MULTI-INSTITUTION STUDY.

    Science.gov (United States)

    Carmalt, James L; Kneissl, Sibylle; Rawlinson, Jennifer E; Zwick, Timo; Zekas, Lisa; Ohlerth, Stefanie; Bienert-Zeit, Astrid

    2016-05-01

    Published descriptions of nonseptic arthritis of the equine temporomandibular joint (TMJ) are rare and large studies investigating variations in the TMJ for asymptomatic horses are lacking. The objectives of this cross-sectional, retrospective, multi-institutional study were to describe anatomical variations in the TMJ detected using computed tomography (CT) in an equid population asymptomatic for TMJ disease and determine whether these variations were associated with patient signalment, reason for CT examination, or CT slice width. Medical records at eight hospitals were searched for horses that had head/neck CT scans and no clinical signs of TMJ disease. Age, breed, sex, clinical presentation, and CT slice width data were recorded. Alterations in CT contour and density of the mandibular condyles, mandibular fossae, and TMJ intra-articular discs were described for each horse. Generalized logistic regression was used to test associations between anatomical variations and horse age. A total of 1018 horses were sampled. Anatomical variations were found in TMJ CT images for 40% of horses and 29% of joints. These were dichotomous with regard to age. Horses horses commonly had spherical hypodensities within the mandibular condyles consistent with bone cysts; and hyperdense regions of the intra-articular disc consistent with dystrophic mineralization. Findings indicated that TMJ anatomic variations were common in CT images of younger and older horses asymptomatic for TMJ disease. Future studies are needed to more definitively characterize these CT variations using gross pathology and histopathology. © 2016 American College of Veterinary Radiology.

  15. Computerized tomography in the diagnosis of mechanical jaundice

    International Nuclear Information System (INIS)

    Grushin, Yu.V.; Manasov, T.Zh.; Raskolenko, A.A.; Nazyrova, N.K.; Dzhumashev, E.Z.

    1987-01-01

    A total of 51 patients with suspected mechanical jaundice were examined using the 3rd generation computerized tomograph. A correct conclusion as to the level and mechanism of obstruction was made in 77% of cases. The most serious problems arose in analysis of extrahepatic biliary ducts. The dilatation of the biliary passages was not always combined with their obturation. In cases which were difficult for interpretation, additional information could be obtained by using thin tomographic layers, i.v. contrast enhancement, and retrograde endoscopic cholangiography

  16. Seismic anisotropy in tomographic studies of the upper mantle beneath Southern Europe

    Directory of Open Access Journals (Sweden)

    J. Plomerovà

    1997-06-01

    Full Text Available Regional seismic tomography of Iberia, Italy, the South Balkans and the Aegean region down to about 400 km are discussed along with results of studies on the anisotropic structure of the lithosphere based on an analysis of spatial variations of P-residuals. The P-residual spheres, showing azimuth-incidence angle dependent terms of relative residuals, map lateral changes of the anisotropic structure of the subcrustal lithosphere related to large tectonic units. Isotropic velocity perturbation models correlate, in general, with models of the lithosphere thickness but in some provinces they are affected by neglecting the anisotropic propagation within the lithosphere.

  17. Study on the tomographic cerebral blood flow measurement with stable xenon inhalation

    International Nuclear Information System (INIS)

    Kimura, Kazumoto; Ueda, Yasuichi; Nagai, Masakatsu; Segawa, Hiromu.

    1983-01-01

    This study was conducted to obtain quantitative values of regional cerebral blood flow (rCBF) by serial CT scanning during non radioactive xenon (Xe) inhalation. The present study provided not only rCBF map but build up rate (k) map and partition coefficient (lambda) map both in normal and pathological brain tissues. The lambda map can not be readily obtained by radioisotope (RI) or positron emission CT method. These maps provided high resolution enough to identify white matter, gray matter and even deep structure of the brain such as caudate nucles, thalums and internal capsule, and were directly compared with CT image. Resolution of each map permited visualization of small area as much as 1-3 mm in diameter. Blood flow for gray matter was 82+-11 and that for white matter was 24+-5 ml/100 g/min in seven normal subjects. The inhalation time of Xe gas and the scanning interval influenced the k, lambda, and rCBF map, respectively. In order to visualize the distribution of white matter on lambda map, it required more than 20 min inhalation of the gas. The scanning interval for good map was every 3 min in the first 9 min and every 5 min in the later period. (author)

  18. Study and development of a high resolution tomograph for the {gamma} radio-imagery in vivo of small animals; Etude et developpement d`un tomographe haute resolution pour la radio-imagerie {gamma} in vivo de petits animaux

    Energy Technology Data Exchange (ETDEWEB)

    Valda Ochoa, A

    1995-06-23

    By the use of molecular radio-labelled tracers, molecular biology can reveal some aspects of the functional organisation of the brain. Non invasive in vivo brain research on small laboratory animals, like mice or rats, require analysis of structures of some cubic millimeters present in a brain of the order of a cubic centimeter. Since imaging performances of positron emission tomography (PET) and single photon emission tomography (SPECT) fail in this research field, we present here a high resolution tomograph (TOHR) based on an original principle that allows to overcome the compromise between detection efficiency and spatial resolution. TOHR is a radiation counter device having a large solid angle focusing collimator. By the use of radio-tracers decaying by a cascade of two photons, coincidence detection offers an accurate delimitation of the analysed region and improves spatial resolution. TOHR acts as a scanner, so the image is built voxel by voxel by moving the animal relative to the detector. A numerical feasibility study of such a system shows that a sub millimeter spatial resolution can be achieved. We show that the chemical etching technique is well suited for manufacturing a multi-module focusing collimator by building and testing two such modules. Finally a numerical simulation exhibits TOHR`s performance in a neuro-pharmacological experiment on a rat. From these results, other application of TOHR are envisaged, such as oncology (in vivo evolution of tumours) or gene therapy (distribution of viral particles in the brain). (author). 51 refs., 73 figs., 3 tabs.

  19. INVESTIGATION OF IMPACTED SUPERNUMERARY TEETH: A CONE BEAM COMPUTED TOMOGRAPH (CBCT STUDY

    Directory of Open Access Journals (Sweden)

    Gökhan GÜRLER

    2017-10-01

    Full Text Available Purpose: The purpose of this study was to investigate the impacted supernumerary teeth which were initially detected on panoramic radiographs by using cone beam computed tomography (CBCT. Materials and Methods: In this retrospective study, supernumerary teeth diagnosed on panoramic radiographs taken from patients who had admitted for routine dental treatment were evaluated using CBCT. Patients’ age, gender, systemic conditions as well as number of supernumerary teeth, unilateral-bilateral presence, anatomical localization (maxilla, mandible, anterior-premolar-molar, mesiodens-lateral-canine, parapremolar-paramolar-distomolar shape (rudimentary, supplemental, tuberculate, odontoma, position (palatal-lingual-buccal-labial-central, shortest distance between the tooth and adjacent cortical plate, complications and treatment were assessed. Results: A total of 47 impacted supernumerary teeth in 34 patients were investigated in this study. Of these, 33 (70.2% were unilateral and 14 (29.8% were bilateral. Only 1 supernumerary tooth was found in 27 patients (79.4% whereas 7 patients (20.6% had 2 or more supernumerary teeth. Most of the teeth located in the anterior region (74.4% of the jaws and maxilla (74.4%. Twenty teeth (42.5% were mesiodens, 11 (23.4% were lateral or canine, 14 (29.7% were parapremolar and 2(4.4% were distomolar. Twenty-seven teeth (57.4% were rudimentary, 15 (31.9% were supplemental and 5 (10.7% were odontoma in shape. The shortest distance between the supernumerary tooth and adjacent cortical plate varied between 0 to 2.5 mm with a mean of 0.66 mm. The most common clinical complaint was the non-eruption of permanent teeth (42.5%. All supernumerary teeth were removed under local anesthesia. Orthodontic traction was performed for those impacted permanent teeth if necessary. Conclusion: Impacted supernumerary teeth are usually in close proximity to cortical bone. Although this may facilitate surgical access, there is a risk of

  20. Are restrictions to behaviour of patients required following fluorine-18 fluorodeoxyglucose positron emission tomographic studies?

    International Nuclear Information System (INIS)

    Cronin, B.; Marsden, P.K.; O'Doherty, M.J.

    1999-01-01

    The clinical use of positron emission tomography (PET) is expanding rapidly in most European countries. It is likely therefore that patients receiving the tracer fluorine-18 fluorodeoxyglucose ( 18 FDG) will be discharged to come into contact with family members, members of the public and ward staff. There are few direct measurements on which to base any recommendations with regard to radiation protection, and so we have measured the dose rates from patients undergoing clinical PET examinations in our centre. Seventy-five patients who underwent whole-body and brain 18 FDG PET examinations were studied. Dose rates were measured at 0.1, 0.5, 1.0 and 2.0 m from the mid thorax on leaving the department. The median administered activity was 323 MBq with a 95th percentile value of 360 MBq. The median dose rates measured at the four distances were 90.0, 35.0, 14.0 and 5.0 μSv h -1 (the median dose rates per unit administered activity at 2 h post injection were 0.31, 0.11, 0.04 and 0.02 μSv h -1 MBq -1 ). The corresponding 95th percentile values were 174.0, 69.0, 29.0 and 7.5 μSv h -1 (0.43, 0.2, 0.08 and 0.03 μSv h -1 MBq -1 ). A number of social situations were modelled and an annual dose limit of 1 mSv was used to determine whether restrictive behavioural advice was required. In the case of nursing staff on wards a value of 6 mSv was regarded as the annual limit, which translates to a daily limit of approximately 24 μSv. There is no need for restrictive advice for patients travelling by public or private transport when they leave the department 2 h after the administration of 18 FDG. Similarly, there is no need for restrictive advice with regard to their contact with partners, work colleagues or children of any age, although it should be stressed that children should not accompany the patient to the scanning department. The only possible area of concern is in an oncology ward, where patients may be regularly referred for PET investigations and other high activity

  1. Recovery of atrophic leg muscles in the hemiplegics due to cerebrovascular accidents. Computed tomographic study

    Energy Technology Data Exchange (ETDEWEB)

    Odajima, Natsu; Ishiai, Sumio; Okiyama, Ryouichi; Furukawa, Tetsuo; Tsukagoshi, Hiroshi.

    1988-02-01

    Thirty-five patients with hemiplegia due to cerebrovascular accidents were studied with regared to the muscle wastings before and after rehabilitation training. Hemiplegics were composed of 12 improved and 23 non-improved patients. The CT scan was carried out at the midportion of the thigh and largest-diameter section of the calf. Muscle size of each cross-sectional area was measured on CT image and the increase of size (..delta..S) in each muscle after training was calculated. The ..delta..S of quadriceps femoris was correlated with that of whole cross-section of the thigh. The gracilis in non-affected side was not correlated with that of whole muscles. In both legs, there was an increase in leg muscle size after training. These changes were nost marked in the non-affected side of the improved patients. After training the difference between the two limbs remained unchanged. Recovery of muscle wasting in both legs was seen first in the quadriceps in thigh and flexors in calf. Gracilis was relatively unchanged in comparison with other muscles. Remarkable increase of muscle size in non-affected side was worthwhile to note.

  2. Significance of frontal cortical atrophy in Parkinson's disease: computed tomographic study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Sang; Suh, Jung Ho; Chung, Tae Sub; Kim, Dong Ik [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1987-10-15

    Fifty-five patients with Parkinson's disease were evaluated clinically and with brain computed tomography (CT) in order to determine the incidence of frontal cortical and subcortical atrophy. Twenty cases of age-related healthy control group were also scanned. The CT criteria of frontal cortical atrophy that was used in this study were the maximum width of frontal hemispheric cortical sulci and width of anterior interhemispheric fissure between frontal lobes comparing with maximum width of hemispheric cortical sulci except frontal lobes. And the criteria of frontal subcortical atrophy were bifrontal index bicaudate index, and Evans index. The results are as follows: 1. Cortical atrophic changes in Parkinson's disease were more prominent in frontal lobe rather than other causes of cortical atrophy. 2. Frontal cortical and subcortical atrophic changes were also more prominent in Parkinson's disease rather than age-related control group. 3. Subcortical atrophic changes in frontal lobe were always associated with cortical atrophic changes. 4. Changes of basal ganglia were hardly seen in Parkinson's disease. 5. Cortical atrophic changes in frontal lobe must be the one of significant findings in Parkinson's disease.

  3. Significance of frontal cortical atrophy in Parkinson's disease: computed tomographic study

    International Nuclear Information System (INIS)

    Lee, Kyung Sang; Suh, Jung Ho; Chung, Tae Sub; Kim, Dong Ik

    1987-01-01

    Fifty-five patients with Parkinson's disease were evaluated clinically and with brain computed tomography (CT) in order to determine the incidence of frontal cortical and subcortical atrophy. Twenty cases of age-related healthy control group were also scanned. The CT criteria of frontal cortical atrophy that was used in this study were the maximum width of frontal hemispheric cortical sulci and width of anterior interhemispheric fissure between frontal lobes comparing with maximum width of hemispheric cortical sulci except frontal lobes. And the criteria of frontal subcortical atrophy were bifrontal index bicaudate index, and Evans index. The results are as follows: 1. Cortical atrophic changes in Parkinson's disease were more prominent in frontal lobe rather than other causes of cortical atrophy. 2. Frontal cortical and subcortical atrophic changes were also more prominent in Parkinson's disease rather than age-related control group. 3. Subcortical atrophic changes in frontal lobe were always associated with cortical atrophic changes. 4. Changes of basal ganglia were hardly seen in Parkinson's disease. 5. Cortical atrophic changes in frontal lobe must be the one of significant findings in Parkinson's disease

  4. Positron emission tomographic studies using C-11-glucose in normal aging and cerebrovascular dementia

    International Nuclear Information System (INIS)

    Ujike, Takashi; Terashi, Akiro; Soeda, Toshiyuki; Kitamura, Shin; Kato, Toshiaki; Iio, Masaaki.

    1984-01-01

    Seven normal volunteers and 11 patients with cerebrovascular dementia were studied about the relations between effect of aging, severity of dementia, cerebral glucose metabolism and metabolic response to verbal stimuli by positron emission tomography (PET) using C-11-glucose. Regional distribution of glycogenic metabolites (RDGM: mg/100 g brain), which was a semi-quantitation of the pool of glycogenic metabolites mainly amino acids, were calculated. The RDGM values in elder normal subjects were significantly low compared with young normal subjects in frontal cortex (p < 0.05). The decline in frontal cortex metabolism could have been caused by the morphological changes in the course of aging. In temporal cortex, there was no significance between two groups. RDGM increased significantly respond to the verbal stimuli in frontal and temporal cortex both young and elder normal subjects. The RDGM values in vascular dementias were significantly low (p < 0.001) compared with elder normal subjects' in frontal and temporal cortex. Significant difference existed between mild and severe dementia in frontal cortex (p < 0.05). However, there was no significance between mild and severe dementias in temporal cortex. In mild dementias, RDGM increased significantly respond to the verbal stimuli in frontal and temporal cortex. In severe dementias, metabolic response to the verbal stimuli was less or lacking. Our results suggest that the cerebral metabolic functional reserve and the ability of the cerebral cortex to function respond to psychophysiologic stimulation are preserved in young and elder normal subjects and mild cerebrovascular dementias. (J.P.N.)

  5. Study of metastatic lymph nodes in advanced gastric cancer with spiral computed tomograph

    International Nuclear Information System (INIS)

    Su Yijuan

    2008-01-01

    Objective: To study the characteristics of spiral computed tomography (SCT) in the diagnosis of lymph nodes metastases in gastric cancer. Methods: The characteristics of spiral computed tomography (SCT) of metastatic lymph nodes in 35 gastric cancer patients were analyzed and compared with operation and pathology. Results: A total amount of 379 lymph nodes (positive 173, negative 206) were detected by SCT and confirmed by pathology in metastasis-positive or metastasis-negative patients. The positive rate with diameter of lymph nodes ≥ 10 mm is 62.7%. The positive rate with ir- regular shape and uneven enhancement lymph nodes were 96.3% and 89.4%. If the attenuation values, more than or equal to 25 HU in plain scan or 70 HU in arterial phase or 80 HU in venous phase, were used as the threshold to detect the metastasis-positive lymph nodes, the positive rate were 55.7%, 56.3%, 67.8% respectively. Conclusion: SCT is valuable in judging the metastasis in gastric cancer. The reference of diameter ≥ 10mm, combining with the shape and the attenuation values can dramatically improve the diagnosis of lymph node metastasis in gastric cancer. (authors)

  6. Dynamic PET simulator via tomographic emission projection for kinetic modeling and parametric image studies.

    Science.gov (United States)

    Häggström, Ida; Beattie, Bradley J; Schmidtlein, C Ross

    2016-06-01

    To develop and evaluate a fast and simple tool called dpetstep (Dynamic PET Simulator of Tracers via Emission Projection), for dynamic PET simulations as an alternative to Monte Carlo (MC), useful for educational purposes and evaluation of the effects of the clinical environment, postprocessing choices, etc., on dynamic and parametric images. The tool was developed in matlab using both new and previously reported modules of petstep (PET Simulator of Tracers via Emission Projection). Time activity curves are generated for each voxel of the input parametric image, whereby effects of imaging system blurring, counting noise, scatters, randoms, and attenuation are simulated for each frame. Each frame is then reconstructed into images according to the user specified method, settings, and corrections. Reconstructed images were compared to MC data, and simple Gaussian noised time activity curves (GAUSS). dpetstep was 8000 times faster than MC. Dynamic images from dpetstep had a root mean square error that was within 4% on average of that of MC images, whereas the GAUSS images were within 11%. The average bias in dpetstep and MC images was the same, while GAUSS differed by 3% points. Noise profiles in dpetstep images conformed well to MC images, confirmed visually by scatter plot histograms, and statistically by tumor region of interest histogram comparisons that showed no significant differences (p dynamic PET and parametric images, and demonstrated that it generates both images and subsequent parametric images with very similar noise properties to those of MC images, in a fraction of the time. They believe dpetstep to be very useful for generating fast, simple, and realistic results, however since it uses simple scatter and random models it may not be suitable for studies investigating these phenomena. dpetstep can be downloaded free of cost from https://github.com/CRossSchmidtlein/dPETSTEP.

  7. Dynamic PET simulator via tomographic emission projection for kinetic modeling and parametric image studies

    Energy Technology Data Exchange (ETDEWEB)

    Häggström, Ida, E-mail: haeggsti@mskcc.org [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065 and Department of Radiation Sciences, Umeå University, Umeå 90187 (Sweden); Beattie, Bradley J.; Schmidtlein, C. Ross [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States)

    2016-06-15

    studies investigating these phenomena. dPETSTEP can be downloaded free of cost from https://github.com/CRossSchmidtlein/dPETSTEP.

  8. Dynamic PET simulator via tomographic emission projection for kinetic modeling and parametric image studies

    International Nuclear Information System (INIS)

    Häggström, Ida; Beattie, Bradley J.; Schmidtlein, C. Ross

    2016-01-01

    studies investigating these phenomena. dPETSTEP can be downloaded free of cost from https://github.com/CRossSchmidtlein/dPETSTEP.

  9. A study of root canal morphology of human primary incisors and molars using cone beam computerized tomography: An in vitro study

    OpenAIRE

    Vivek Gaurav; Nikhil Srivastava; Vivek Rana; Vivek Kumar Adlakha

    2013-01-01

    Background: Variations in morphology of root canals in primary teeth usually leads to complications during and after endodontic therapy. To improve the success in endodontics, a thorough knowledge of the root canal morphology is essential. Aim: The aim of this study was to assess the variation in number and morphology of the root canals of primary incisors and molars and to study the applicability of cone beam computerized tomography (CBCT) in assessing the same. Settings and Design: A total ...

  10. Computerization of the standard corsi block-tapping task affects its underlying cognitive concepts : A pilot study

    NARCIS (Netherlands)

    Claessen, Michiel H G; Van Der Ham, Ineke J M; Van Zandvoort, Martine J E

    2015-01-01

    The tablet computer initiates an important step toward computerized administration of neuropsychological tests. Because of its lack of standardization, the Corsi Block-Tapping Task could benefit from advantages inherent to computerization. This task, which requires reproduction of a sequence of

  11. Computerization of the Standard Corsi Block-Tapping Task Affects Its Underlying Cognitive Concepts : A Pilot Study

    NARCIS (Netherlands)

    Claessen, Michiel H G; Van Der Ham, Ineke J M; Van Zandvoort, Martine J E

    2014-01-01

    The tablet computer initiates an important step toward computerized administration of neuropsychological tests. Because of its lack of standardization, the Corsi Block-Tapping Task could benefit from advantages inherent to computerization. This task, which requires reproduction of a sequence of

  12. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to the means of adjusting the apparent gain of the signal processing means for receiving output signals from the detectors, to compensate for drift in the gain characteristics, including means for passing a reference signal. (U.K.)

  13. Study, development and validation of a dead-timeless electronic architecture concept for highly sensitive PET (Positron Emission Tomograph)

    International Nuclear Information System (INIS)

    Vert, P.E.

    2007-03-01

    Positron emission tomographs (PET) are fitted with highly capable reading electronics, which owns qualities and drawbacks. Highly accused at first as an explanation of the poor sensitivity of these imagers, the present study points out that the dead-times shared along the chains contribute to only 16 % in the data losses at a typical activity of 10 μCi/ml. The gross acquisition rates could thus be raised by 20 % through a suppression of these saturations. Looking in details at the philosophy of the acquisition procedure, a property appears to circumscribe the sensitivity even more: the timing resolution. The latter conditions, to the first order, the rejection capabilities of random events, part of the scattered ones and hence noise which is finally rated to the true coincidences the signal is made up of. Minimizing the resolving time goes through the suppression of the unneeded actors along with the adoption of a well adapted time-stamping method (optimal filtering). In doing so, the intrinsic channel resolution appears to be possibly lowered by a factor 7, reducing to 350 ps. The bottom value of the coincidence window may be narrowed as a consequence, leading to an increase of the NECR (noise equivalent count rate) by 50 per cent. At this stage, a time of flight (TOF) algorithms can be implemented. As an opportunist, it promises a reduction of the noise variance by 430 %, a gain that echoes on the NECR figure. Finally merging all these ideas allows to expect an improvement close to an order of magnitude on the NECR, with the hope of routine exams shortened by the same amount. In this context, it appeared logical to imagine a new electronics acquisition synoptic dedicated to fully pixelized PET. The number of channels blows up by the way when compared to the existing, this statement being partially balanced by the decision to fully integrate the electronics. The measures of the energy and time are planned to be performed with a single channel, with a continuous

  14. Influence of contrast media viscosity and temperature on injection pressure in computed tomographic angiography: a phantom study.

    Science.gov (United States)

    Kok, Madeleine; Mihl, Casper; Mingels, Alma A; Kietselaer, Bas L; Mühlenbruch, Georg; Seehofnerova, Anna; Wildberger, Joachim E; Das, Marco

    2014-04-01

    Iodinated contrast media (CM) in computed tomographic angiography is characterized by its concentration and, consecutively, by its viscosity. Viscosity itself is directly influenced by temperature, which will furthermore affect injection pressure. Therefore, the purposes of this study were to systematically evaluate the viscosity of different CM at different temperatures and to assess their impact on injection pressure in a circulation phantom. Initially, viscosity of different contrast media concentrations (240, 300, 370, and 400 mgI/mL) was measured at different temperatures (20°C-40°C) with a commercially available viscosimeter. In the next step, a circulation phantom with physical conditions was used. Contrast media were prepared at different temperatures (20°C, 30°C, 37°C) and injected through a standard 18-gauge needle. All other relevant parameters were kept constant (iodine delivery rate, 1.9 g I/s; total amount of iodine, 15 g I). Peak flow rate (in milliliter per second) and injection pressure (psi) were monitored. Differences in significance were tested using the Kruskal-Wallis test (Statistical Package for the Social Sciences). Viscosities for iodinated CM of 240, 300, 370, and 400 mg I/mL at 20°C were 5.1, 9.1, 21.2, and 28.8 mPa.s, respectively, whereas, at 40°C, these were substantially lower (2.8, 4.4, 8.7, and 11.2 mPa.s). In the circulation phantom, mean (SD) peak pressures for CM of 240 mg I/mL at 20°C, 30°C, and 37°C were 107 (1.5), 95 (0.6), and 92 (2.1) psi; for CM of 300 mg I/mL, 119 (1.5), 104 (0.6), and 100 (3.6) psi; for CM of 370 mg I/mL, 150 (0.6), 133 (4.4), and 120 (3.5) psi; and for CM of 400 mg I/mL, 169 (1.0), 140 (2.1), and 135 (2.9) psi, respectively, with all P values less than 0.05. Low concentration, low viscosity, and high temperatures of CM are beneficial in terms of injection pressure. This should also be considered for individually tailored contrast protocols in daily routine scanning.

  15. Study of the Switching Errors in an RSFQ Switch by Using a Computerized Test Setup

    International Nuclear Information System (INIS)

    Kim, Se Hoon; Baek, Seung Hun; Yang, Jung Kuk; Kim, Jun Ho; Kang, Joon Hee

    2005-01-01

    The problem of fluctuation-induced digital errors in a rapid single flux quantum (RSFQ) circuit has been a very important issue. In this work, we calculated the bit error rate of an RSFQ switch used in superconductive arithmetic logic unit (ALU). RSFQ switch should have a very low error rate in the optimal bias. Theoretical estimates of the RSFQ error rate are on the order of 10 -50 per bit operation. In this experiment, we prepared two identical circuits placed in parallel. Each circuit was composed of 10 Josephson transmission lines (JTLs) connected in series with an RSFQ switch placed in the middle of the 10 JTLs. We used a splitter to feed the same input signal to both circuits. The outputs of the two circuits were compared with an RSFQ exclusive OR (XOR) to measure the bit error rate of the RSFQ switch. By using a computerized bit-error-rate test setup, we measured the bit error rate of 2.18 x 10 -12 when the bias to the RSFQ switch was 0.398 mA that was quite off from the optimum bias of 0.6 mA.

  16. STUDY ABOUT A FURNITURE COMPANY THAT USES NEW TECHNOLOGIES AND COMPUTERIZED EQUIPMENT

    Directory of Open Access Journals (Sweden)

    PUSTIANU Monica

    2015-05-01

    Full Text Available In Romania, there are companies that uses new technologies and computerized equipment leading to obtaining high quality products and profit. Furniture industry has continuously developed due to high demand for diversified products for all age groups. Romanian goods shall be delivered both in the country and abroad. The tapestries furniture made in our country, classical or modern, by leather in different colours or with textile coating materials fashionable chosen is already enjoying much attention from the external and internal customers. The workforce employed in the furniture manufacturing industry is qualified, managed to shape the wood into complex and elegant products that are able to give full satisfaction to all consumers SWOT analysis is defined as a complex research of economic aspects, technical, sociological, legal and managerial aspects that characterize the activity of a company and allows the formulation of an opinion on the past and present condition of the company. SWOT analysis may be carried out both at the level of functional areas of the company: financial, commercial, production, human resources, research and development, management and at the level of firm as a whole. By this analysis was obtained a clear picture of the current state of the analysed company, helping to knowledge and understanding of the general context in which the company operates. Key words: quality, furniture, management, production, analysis, SWOT

  17. Computerized infrared spectroscopic study of surface reactions on selected lanthanide oxides

    International Nuclear Information System (INIS)

    Dellisante, G.N.

    1982-01-01

    The natures of adsorption sites on La 2 O 3 , Nd 2 O 3 , and selected praseodymium oxides were investigated by examining surface reactions of probe molecules using computerized transmission ir spectroscopy on unsupported samples. Additionally, the rehydration/dehydration behavior and crystallographic phase transitions of these oxides were examined in pretreatment temperature experiments involving rehydration of the sesquioxides to hydroxides by water exposure. Following rehydration of La 2 O 3 to La(OH) 3 , the effect of increasing vacuum pretreatment temperature (350 to 1000 0 C) is to gradually remove surface hydroxyl and carbonate entities (up to 650 0 C), and increase the degree of A-type crystallinity. Increasing crystallinity causes a concomitant decrease in surface oxide basicity. The removal of hydroxyl and carbonate species, as well as increases in oxide basicity, strongly correlated to increases in certain catalytic activities. The adsorption of NH 3 , CO 2 , mixtures of NH 3 and CO 2 , formic acid, acetic acid, acetaldehyde, and ethanol on the oxides was determined to weakly coordinate in Ln 3 + sites, and the surface reactions are discussed. Heating was found to desorb the adsorbed compounds and/or causes changes of the originally adsorbed form into other compounds. The effects of temperature on both adsorption and desorption are reported

  18. Computerized surveillance of opioid-related adverse drug events in perioperative care: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Gattis Katherine G

    2009-08-01

    events. Conclusion A small investment of resources into a pharmacist-driven surveillance model gave great gains in organizational adverse drug event detection. The patients who experienced multiple events are particularly relevant to future studies seeking risk factors for opioid induced respiratory depression. Computerized surveillance is an efficient, impactful, and sustainable model for ongoing capture and analysis of these rare, but potentially serious events.

  19. Evaluation of quality of tomographs of Rio de Janeiro state, Brazil

    International Nuclear Information System (INIS)

    Travassos, P.C.B.; Belem, V.R.; Magalhaes, L.A.; Almeida, C.E.A. de

    2014-01-01

    Computerized tomographs used in 56 institutions in the state of Rio de Janeiro were evaluated. Criteria of image quality and dosimetry were submitted. The results showed that some not performed optimize their protocols examinations or perform wrongly, which results in an increase in the dose received by patients, and an image in compromised quality. (author)

  20. Computerized tomography system

    International Nuclear Information System (INIS)

    Hellstrom, M.; Kutlik, E.; Perlin, A.

    1980-01-01

    A method for non-mechanically linking the motions of an x-ray source with an x-ray receptor during a tomographic procedure to produce a tomograph of a section of an object under examination comprising the steps of: effecting motion of said source and receptor to respective reference positions; thereafter during a tomographic procedural mode generating from at least one fixed frequency signal source first and second pulse trains, adapted to drive respective stepper motors, for effecting motion of said source and receptor, said pulse trains having a predetermined mathematical relationship dependent upon the desired fulcrum height of the tomographic section to be produced; and applying said first and second pulse trains to the respective stepper motors for a predetermined number of pulse counts to effect motion with respect to said respective reference positions and effecting a tomographic sweep thereby

  1. Influence of using a single facial vein as outflow in full-face transplantation: A three-dimensional computed tomographic study.

    Science.gov (United States)

    Rodriguez-Lorenzo, Andres; Audolfsson, Thorir; Wong, Corrine; Cheng, Angela; Arbique, Gary; Nowinski, Daniel; Rozen, Shai

    2015-10-01

    The aim of this study was to evaluate the contribution of a single unilateral facial vein in the venous outflow of total-face allograft using three-dimensional computed tomographic imaging techniques to further elucidate the mechanisms of venous complications following total-face transplant. Full-face soft-tissue flaps were harvested from fresh adult human cadavers. A single facial vein was identified and injected distally to the submandibular gland with a radiopaque contrast (barium sulfate/gelatin mixture) in every specimen. Following vascular injections, three-dimensional computed tomographic venographies of the faces were performed. Images were viewed using TeraRecon Software (Teracon, Inc., San Mateo, CA, USA) allowing analysis of the venous anatomy and perfusion in different facial subunits by observing radiopaque filling venous patterns. Three-dimensional computed tomographic venographies demonstrated a venous network with different degrees of perfusion in subunits of the face in relation to the facial vein injection side: 100% of ipsilateral and contralateral forehead units, 100% of ipsilateral and 75% of contralateral periorbital units, 100% of ipsilateral and 25% of contralateral cheek units, 100% of ipsilateral and 75% of contralateral nose units, 100% of ipsilateral and 75% of contralateral upper lip units, 100% of ipsilateral and 25% of contralateral lower lip units, and 50% of ipsilateral and 25% of contralateral chin units. Venographies of the full-face grafts revealed better perfusion in the ipsilateral hemifaces from the facial vein in comparison with the contralateral hemifaces. Reduced perfusion was observed mostly in the contralateral cheek unit and contralateral lower face including the lower lip and chin units. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Computerized control of circulation. Optimal storage climate with minimal energy consumption. Pilot study; Computergestuurde Circulatieregelingen. Optimaal bewaarklimaat met minimaal energieverbruik. Praktijkonderzoek

    Energy Technology Data Exchange (ETDEWEB)

    Wildschut, J. [Praktijkonderzoek Plant en Omgeving PPO, Bloembollen, Boomkwekerij en Fruit, Lisse (Netherlands); Janssen, H.H.J.; Gielen, T.G.; Sapounas, A. [WUR Glastuinbouw, Wageningen (Netherlands)

    2011-04-15

    The objective of this study is to develop computerized controls for circulation that are based on sensors, allowing for significant conservation in the electricity use of circulation [Dutch] Doelstelling van dit project is het ontwikkelen van op sensoren gebaseerde computergestuurde regelingen voor de circulatie, waardoor bij een optimaal bewaarklimaat voor alle bolgewassen zeer fors op het elektraverbruik voor circulatie bespaard kan worden.

  3. Axial tomographic scanner

    International Nuclear Information System (INIS)

    1976-01-01

    An axial tomographic system is described comprising axial tomographic means for collecting sets of data corresponding to the transmission or absorption of a number of beams of penetrating radiation through a planar slice of an object. It includes means to locate an object to be analyzed, a source and detector for directing one or more beams of penetrating radiation through the object from the source to the detector, and means to rotate (and optionally translate) the source as well as means to process the collected sets of data. Data collection, data processing, and data display can each be conducted independently of each other. An additional advantage of the system described is that the raw data (i.e., the originally collected data) are not destroyed by the data processing but instead are retained intact for further reference or use, if needed

  4. Tomographic method and apparatus

    International Nuclear Information System (INIS)

    Moore, R.M.

    1981-01-01

    A tomographic x-ray machine has a camera and film-plane section which move about a primary axis for imaging a selected cross-section of an anatomical member onto the film. A ''scout image'' of the member is taken at right angles to the plane of the desired cross-section to indicate the cross-section's angle with respect to the primary axis. The film plane is then located at the same angle with respect to a film cassette axis as the selected cross-section makes with the primary axis. The film plane and the cross-section are then maintained in parallel planes throughout motion of the camera and film plane during tomographic radiography. (author)

  5. [Is the ICU staff satisfied with the computerized physician order entry? A cross-sectional survey study].

    Science.gov (United States)

    Fumis, Renata Rego Lins; Costa, Eduardo Leite Vieira; Martins, Paulo Sergio; Pizzo, Vladimir; Souza, Ivens Augusto; Schettino, Guilherme de Paula Pinto

    2014-01-01

    To evaluate the satisfaction of the intensive care unit staff with a computerized physician order entry and to compare the concept of the computerized physician order entry relevance among intensive care unit healthcare workers. We performed a cross-sectional survey to assess the satisfaction of the intensive care unit staff with the computerized physician order entry in a 30-bed medical/surgical adult intensive care unit using a self-administered questionnaire. The questions used for grading satisfaction levels were answered according to a numerical scale that ranged from 1 point (low satisfaction) to 10 points (high satisfaction). The majority of the respondents (n=250) were female (66%) between the ages of 30 and 35 years of age (69%). The overall satisfaction with the computerized physician order entry scored 5.74±2.14 points. The satisfaction was lower among physicians (n=42) than among nurses, nurse technicians, respiratory therapists, clinical pharmacists and diet specialists (4.62±1.79 versus 5.97±2.14, phealthcare workers were satisfied, albeit not entirely, with the computerized physician order entry. The overall users' satisfaction with computerized physician order entry was lower among physicians compared to other healthcare professionals. The factors associated with satisfaction included the belief that digitalization decreased the workload and contributed to the intensive care unit quality with a user-friendly and accurate system and that digitalization provided concise information within a reasonable time frame.

  6. Post-hoc simulation study to adopt a computerized adaptive testing (CAT) for a Korean Medical License Examination.

    Science.gov (United States)

    Seo, Dong Gi; Choi, Jeongwook

    2018-05-17

    Computerized adaptive testing (CAT) has been adopted in license examinations due to a test efficiency and accuracy. Many research about CAT have been published to prove the efficiency and accuracy of measurement. This simulation study investigated scoring method and item selection methods to implement CAT in Korean medical license examination (KMLE). This study used post-hoc (real data) simulation design. The item bank used in this study was designed with all items in a 2017 KMLE. All CAT algorithms for this study were implemented by a 'catR' package in R program. In terms of accuracy, Rasch and 2parametric logistic (PL) model performed better than 3PL model. Modal a Posteriori (MAP) or Expected a Posterior (EAP) provided more accurate estimates than MLE and WLE. Furthermore Maximum posterior weighted information (MPWI) or Minimum expected posterior variance (MEPV) performed better than other item selection methods. In terms of efficiency, Rasch model was recommended to reduce test length. Simulation study should be performed under varied test conditions before adopting a live CAT. Based on a simulation study, specific scoring and item selection methods should be predetermined before implementing a live CAT.

  7. Enrollment into a time sensitive clinical study in the critical care setting: results from computerized septic shock sniffer implementation

    Science.gov (United States)

    Pieper, Matthew S; Pulido, Juan; Gajic, Ognjen

    2011-01-01

    Objective Recruitment of patients into time sensitive clinical trials in intensive care units (ICU) poses a significant challenge. Enrollment is limited by delayed recognition and late notification of research personnel. The objective of the present study was to evaluate the effectiveness of the implementation of electronic screening (septic shock sniffer) regarding enrollment into a time sensitive (24 h after onset) clinical study of echocardiography in severe sepsis and septic shock. Design We developed and tested a near-real time computerized alert system, the septic shock sniffer, based on established severe sepsis/septic shock diagnostic criteria. A sniffer scanned patients' data in the electronic medical records and notified the research coordinator on call through an institutional paging system of potentially eligible patients. Measurement The performance of the septic shock sniffer was assessed. Results The septic shock sniffer performed well with a positive predictive value of 34%. Electronic screening doubled enrollment, with 68 of 4460 ICU admissions enrolled during the 9 months after implementation versus 37 of 4149 ICU admissions before sniffer implementation (p<0.05). Efficiency was limited by study coordinator availability (not available at nights or weekends). Conclusions Automated electronic medical records screening improves the efficiency of enrollment and should be a routine tool for the recruitment of patients into time sensitive clinical trials in the ICU setting. PMID:21508415

  8. Enrollment into a time sensitive clinical study in the critical care setting: results from computerized septic shock sniffer implementation.

    Science.gov (United States)

    Herasevich, Vitaly; Pieper, Matthew S; Pulido, Juan; Gajic, Ognjen

    2011-01-01

    Recruitment of patients into time sensitive clinical trials in intensive care units (ICU) poses a significant challenge. Enrollment is limited by delayed recognition and late notification of research personnel. The objective of the present study was to evaluate the effectiveness of the implementation of electronic screening (septic shock sniffer) regarding enrollment into a time sensitive (24 h after onset) clinical study of echocardiography in severe sepsis and septic shock. We developed and tested a near-real time computerized alert system, the septic shock sniffer, based on established severe sepsis/septic shock diagnostic criteria. A sniffer scanned patients' data in the electronic medical records and notified the research coordinator on call through an institutional paging system of potentially eligible patients. The performance of the septic shock sniffer was assessed. The septic shock sniffer performed well with a positive predictive value of 34%. Electronic screening doubled enrollment, with 68 of 4460 ICU admissions enrolled during the 9 months after implementation versus 37 of 4149 ICU admissions before sniffer implementation (p<0.05). Efficiency was limited by study coordinator availability (not available at nights or weekends). Automated electronic medical records screening improves the efficiency of enrollment and should be a routine tool for the recruitment of patients into time sensitive clinical trials in the ICU setting.

  9. Decomposition of time-resolved tomographic PIV

    NARCIS (Netherlands)

    Schmid, P.J.; Violato, D.; Scarano, F.

    2012-01-01

    An experimental study has been conducted on a transitional water jet at a Reynolds number of Re = 5,000. Flow fields have been obtained by means of time-resolved tomographic particle image velocimetry capturing all relevant spatial and temporal scales. The measured threedimensional flow fields have

  10. A study of total measurement error in tomographic gamma scanning to assay nuclear material with emphasis on a bias issue for low-activity samples

    International Nuclear Information System (INIS)

    Burr, T.L.; Mercer, D.J.; Prettyman, T.H.

    1998-01-01

    Field experience with the tomographic gamma scanner to assay nuclear material suggests that the analysis techniques can significantly impact the assay uncertainty. For example, currently implemented image reconstruction methods exhibit a positive bias for low-activity samples. Preliminary studies indicate that bias reduction could be achieved at the expense of increased random error variance. In this paper, the authors examine three possible bias sources: (1) measurement error in the estimated transmission matrix, (2) the positivity constraint on the estimated mass of nuclear material, and (3) improper treatment of the measurement error structure. The authors present results from many small-scale simulation studies to examine this bias/variance tradeoff for a few image reconstruction methods in the presence of the three possible bias sources

  11. The effectiveness of the computerized visual perceptual training program on individuals with Down syndrome: An fMRI study.

    Science.gov (United States)

    Wan, Yi-Ting; Chiang, Ching-Sui; Chen, Sharon Chia-Ju; Wuang, Yee-Pay

    2017-07-01

    This study investigated the effectiveness of the Computerized Visual Perception Training (CVPT) program on individuals with Down syndrome (DS, mean age=13.17±4.35years, age range: 6.54-20.75 years). All participants have mild intellectual disability classified by the standard IQ measures (mean=61.2, ranges from 55 to 68). Both the Test of Visual Perceptual Skill- Third Edition (TVPS-3) and functional magnetic resonance imaging (fMRI) were used to evaluate the training outcomes. Results of TVPS-3 and fMRI showed that DS group had visual perceptual deficits and abnormal neural networks related to visual organization. The results showed that DS intervention group had significant improvements on TVPS-3 after intervention. The fMRI results indicated more activation in superior and inferior parietal lobes (spatial manipulation), as well as precentral gyrus and dorsal premotor cortex (motor imagery) in DS intervention group. The CVPT program was effective in improving visual perceptual functions and enhancing associated cortical activations in DS. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Spectrophotometric and computerized evaluation of tooth bleaching employing 10 different home-bleaching procedures: In-vitro study

    Science.gov (United States)

    Peskersoy, Cem; Tetik, Ayhan; Ozturk, Veli Ozgen; Gokay, Necmi

    2014-01-01

    Objective: The aim of this in-vitro study was to evaluate the efficacy of bleaching products, determine the applicability and validation of the measurement methods. Materials and Methods: Freshly extracted 110 human incisor teeth were stained with whole blood and hemolysate solution prior to the application of 10 different home-bleaching products. Spectrophotometric measurements of the tooth shades were performed for each specimen before and after bleaching at the 1st, 3rd, 7th, and 14 days. Differences in lightness (Δl), chroma (Δc), hue (Δh) values and shade changes were measured to evaluate process. Computerized digital imaging analyses to determine the color changes were performed with Photoshop CS4 software (Adobe, San Jose, CA, USA). Statistical analyses were performed with analysis of variance, Scheffe and Tukey tests. Results: In all of the test groups regardless of the material used, a significant increase in lightness and hue, and decrease of chroma were observed, as compared to the control group. After recommended bleaching applications, Δl and Δh values respectively increased in group Zaris White and Brite (ZWB) and group Pola Night and Δc values showed significant decrease in groups ZWB and Rembrandt REM3 (P bleaching systems showed slower but almost permanent bleaching effect likewise office-based methods. Both software and spectrophotometric analyses have advantages such as evaluating the results objectively and numerically, also treatment outcomes could be preserved. PMID:25512738

  13. Computerized simulation study of the influence of the different parameters inducing crevice corrosion propagation of passivable alloys in chloride medium

    International Nuclear Information System (INIS)

    Girardin, G.; Proust, A.; Combrade, P.; Vuillemin, B.; Oltra, R.

    2006-01-01

    The most frequent case of crevice corrosion concerns passivable alloys, and particularly stainless steels in oxidizing chloride media. In order to be sure that its propagation is not possible, the corrosion potential has to be inferior to a critical value called 're-passivation potential'. An easy and flexible computerized simulation of the propagation of an active crevice in chloride medium has been developed to give a parametric study of the local medium and of the re-passivation conditions. This modeling allows to establish the stability domains of the solid and gaseous phases inside the crevice and to assess the influence of the potential of the free surfaces, of the amount of chloride in the exterior medium and the geometry on the local chemistry. It appears that the deepest crevices are not necessarily the strongest. The introduction, in crevice tip, of an easy re-passivation criteria shows the existence of a re-passivation potential depending of the crevice geometry. (O.M.)

  14. Computerized tomography magnified bone windows are superior to standard soft tissue windows for accurate measurement of stone size: an in vitro and clinical study.

    Science.gov (United States)

    Eisner, Brian H; Kambadakone, Avinash; Monga, Manoj; Anderson, James K; Thoreson, Andrew A; Lee, Hang; Dretler, Stephen P; Sahani, Dushyant V

    2009-04-01

    We determined the most accurate method of measuring urinary stones on computerized tomography. For the in vitro portion of the study 24 calculi, including 12 calcium oxalate monohydrate and 12 uric acid stones, that had been previously collected at our clinic were measured manually with hand calipers as the gold standard measurement. The calculi were then embedded into human kidney-sized potatoes and scanned using 64-slice multidetector computerized tomography. Computerized tomography measurements were performed at 4 window settings, including standard soft tissue windows (window width-320 and window length-50), standard bone windows (window width-1120 and window length-300), 5.13x magnified soft tissue windows and 5.13x magnified bone windows. Maximum stone dimensions were recorded. For the in vivo portion of the study 41 patients with distal ureteral stones who underwent noncontrast computerized tomography and subsequently spontaneously passed the stones were analyzed. All analyzed stones were 100% calcium oxalate monohydrate or mixed, calcium based stones. Stones were prospectively collected at the clinic and the largest diameter was measured with digital calipers as the gold standard. This was compared to computerized tomography measurements using 4.0x magnified soft tissue windows and 4.0x magnified bone windows. Statistical comparisons were performed using Pearson's correlation and paired t test. In the in vitro portion of the study the most accurate measurements were obtained using 5.13x magnified bone windows with a mean 0.13 mm difference from caliper measurement (p = 0.6). Measurements performed in the soft tissue window with and without magnification, and in the bone window without magnification were significantly different from hand caliper measurements (mean difference 1.2, 1.9 and 1.4 mm, p = 0.003, window settings with magnification. For uric acid calculi the measurement error was observed only in standard soft tissue window settings. In vivo 4.0x

  15. Simulation studies on the tomographic reconstruction of the equatorial and low-latitude ionosphere in the context of the Indian tomography experiment: CRABEX

    Directory of Open Access Journals (Sweden)

    S. V. Thampi

    2004-11-01

    Full Text Available Equatorial ionosphere poses a challenge to any algorithm that is used for tomographic reconstruction because of the phenomena like the Equatorial Ionization Anomaly (EIA and Equatorial Spread F (ESF. Any tomographic reconstruction of ionospheric density distributions in the equatorial region is not acceptable if it does not image these phenomena, which exhibit large spatial and temporal variability, to a reasonable accuracy. The accuracy of the reconstructed image generally depends on many factors, such as the satellite-receiver configuration, the ray path modelling, grid intersections and finally, the reconstruction algorithm. The present simulation study is performed to examine these in the context of the operational Coherent Radio Beacon Experiment (CRABEX network just commenced in India. The feasibility of using this network for the studies of the equatorial and low-latitude ionosphere over Indian longitudes has been investigated through simulations. The electron density distributions that are characteristic of EIA and ESF are fed into various simulations and the reconstructed tomograms are investigated in terms of their reproducing capabilities. It is seen that, with the present receiver chain existing from 8.5° N to 34° N, it would be possible to obtain accurate images of EIA and the plasma bubbles. The Singular Value Decomposition (SVD algorithm has been used for the inversion procedure in this study. As is known, by the very nature of ionospheric tomography experiments, the received data contain various kinds of errors, like the measurement and discretization errors. The sensitivity of the inversion algorithm, SVD in the present case, to these errors has also been investigated and quantified.

  16. High resolution tomographic instrument development

    International Nuclear Information System (INIS)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  17. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  18. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  19. Comparative validity and reproducibility study of various landmark-oriented reference planes in 3-dimensional computed tomographic analysis for patients receiving orthognathic surgery.

    Science.gov (United States)

    Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou

    2015-01-01

    Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. A total of 30 patients with facial deformity and malocclusion--10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate--were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. The 5 horizontal reference planes were reliable and

  20. Is the ICU staff satisfied with the computerized physician order entry? A cross-sectional survey study

    Science.gov (United States)

    Fumis, Renata Rego Lins; Costa, Eduardo Leite Vieira; Martins, Paulo Sergio; Pizzo, Vladimir; Souza, Ivens Augusto; Schettino, Guilherme de Paula Pinto

    2014-01-01

    Objective To evaluate the satisfaction of the intensive care unit staff with a computerized physician order entry and to compare the concept of the computerized physician order entry relevance among intensive care unit healthcare workers. Methods We performed a cross-sectional survey to assess the satisfaction of the intensive care unit staff with the computerized physician order entry in a 30-bed medical/surgical adult intensive care unit using a self-administered questionnaire. The questions used for grading satisfaction levels were answered according to a numerical scale that ranged from 1 point (low satisfaction) to 10 points (high satisfaction). Results The majority of the respondents (n=250) were female (66%) between the ages of 30 and 35 years of age (69%). The overall satisfaction with the computerized physician order entry scored 5.74±2.14 points. The satisfaction was lower among physicians (n=42) than among nurses, nurse technicians, respiratory therapists, clinical pharmacists and diet specialists (4.62±1.79 versus 5.97±2.14, pdigitalization decreased the workload and contributed to the intensive care unit quality with a user-friendly and accurate system and that digitalization provided concise information within a reasonable time frame. PMID:24770682

  1. Computerization of the standard corsi block-tapping task affects its underlying cognitive concepts: a pilot study.

    Science.gov (United States)

    Claessen, Michiel H G; van der Ham, Ineke J M; van Zandvoort, Martine J E

    2015-01-01

    The tablet computer initiates an important step toward computerized administration of neuropsychological tests. Because of its lack of standardization, the Corsi Block-Tapping Task could benefit from advantages inherent to computerization. This task, which requires reproduction of a sequence of movements by tapping blocks as demonstrated by an examiner, is widely used as a representative of visuospatial attention and working memory. The aim was to validate a computerized version of the Corsi Task (e-Corsi) by comparing recall accuracy to that on the standard task. Forty university students (Mage = 22.9 years, SD = 2.7 years; 20 female) performed the standard Corsi Task and the e-Corsi on an iPad 3. Results showed higher accuracy in forward reproduction on the standard Corsi compared with the e-Corsi, whereas backward performance was comparable. These divergent performance patterns on the 2 versions (small-to-medium effect sizes) are explained as a result of motor priming and interference effects. This finding implies that computerization has serious consequences for the cognitive concepts that the Corsi Task is assumed to assess. Hence, whereas the e-Corsi was shown to be useful with respect to administration and registration, these findings also stress the need for reconsideration of the underlying theoretical concepts of this task.

  2. Emission computed tomograph

    International Nuclear Information System (INIS)

    Hirose, Y.; Kanno, I.; Koga, K.; Miura, S.; Uemura, K.

    1981-01-01

    Emission computed tomograph wherein a pluralty of detectors surround an object to be examined so as to detect x- or gamma radiation emitted by said object. In front of each of said detectors there is provided a collimator which comprises a pair of main plates and a subsidiary plate interposed therebetween. The plates are made of a material capable of blocking penetration of the radiation therethrough and so supported as to be swingable over an angle sufficient to cover the whole of said object. The plates of all the collimators are simultaneously swung to the same side and at the same angular speed thereby to change the direction of incidence of said radiation on each of said detectors

  3. Tomographic examination table

    International Nuclear Information System (INIS)

    Redington, R.W.; Henkes, J.L.

    1979-01-01

    Equipment is described for positioning and supporting patients during tomographic mammography using X-rays. The equipment consists of a table and fabric slings which permit the examination of a downward, pendant breast of a prone patient by allowing the breast to pass through a aperture in the table into a fluid filled container. The fluid has an X-ray absorption coefficient similar to that of soft human tissue allowing high density resolution radiography and permitting accurate detection of breast tumours. The shape of the equipment and the positioning of the patient allow the detector and X-ray source to rotate 360 0 about a vertical axis through the breast. This permits the use of relatively simple image reconstruction algorithms and a divergent X-ray geometry. (UK)

  4. Intraosseous anesthesia with solution injection controlled by a computerized system versus conventional oral anesthesia: a preliminary study.

    Science.gov (United States)

    Beneito-Brotons, Rut; Peñarrocha-Oltra, David; Ata-Ali, Javier; Peñarrocha, María

    2012-05-01

    To compare a computerized intraosseous anesthesia system with the conventional oral anesthesia techniques, and analyze the latency and duration of the anesthetic effect and patient preference. A simple-blind prospective study was made between March 2007 and May 2008. Each patient was subjected to two anesthetic techniques: conventional and intraosseous using the Quicksleeper® system (DHT, Cholet, France). A split-mouth design was adopted in which each patient underwent treatment of a tooth with one of the techniques, and treatment of the homologous contralateral tooth with the other technique. The treatments consisted of restorations, endodontic procedures and simple extractions. The study series comprised 12 females and 18 males with a mean age of 36.8 years. The 30 subjects underwent a total of 60 anesthetic procedures. Intraosseous and conventional oral anesthesia caused discomfort during administration in 46.3% and 32.1% of the patients, respectively. The latency was 7.1±2.23 minutes for the conventional technique and 0.48±0.32 for intraosseous anesthesia--the difference being statistically significant. The depth of the anesthetic effect was sufficient to allow the patients to tolerate the dental treatments. The duration of the anesthetic effect in soft tissues was 199.3 minutes with the conventional technique versus only 1.6 minutes with intraosseous anesthesia--the difference between the two techniques being statistically significant. Most of the patients (69.7%) preferred intraosseous anesthesia. The described intraosseous anesthetic system is effective, with a much shorter latency than the conventional technique, sufficient duration of anesthesia to perform the required dental treatments, and with a much lesser soft tissue anesthetic effect. Most of the patients preferred intraosseous anesthesia.

  5. The impact of computerized physician order entry on prescription orders: A quasi-experimental study in Iran

    Science.gov (United States)

    Khammarnia, Mohammad; Sharifian, Roxana; Zand, Farid; Barati, Omid; Keshtkaran, Ali; Sabetian, Golnar; Shahrokh, , Nasim; Setoodezadeh, Fatemeh

    2017-01-01

    Background: One way to reduce medical errors associated with physician orders is computerized physician order entry (CPOE) software. This study was conducted to compare prescription orders between 2 groups before and after CPOE implementation in a hospital. Methods: We conducted a before-after prospective study in 2 intensive care unit (ICU) wards (as intervention and control wards) in the largest tertiary public hospital in South of Iran during 2014 and 2016. All prescription orders were validated by a clinical pharmacist and an ICU physician. The rates of ordering the errors in medical orders were compared before (manual ordering) and after implementation of the CPOE. A standard checklist was used for data collection. For the data analysis, SPSS Version 21, descriptive statistics, and analytical tests such as McNemar, chi-square, and logistic regression were used. Results: The CPOE significantly decreased 2 types of errors, illegible orders and lack of writing the drug form, in the intervention ward compared to the control ward (p< 0.05); however, the 2 errors increased due to the defect in the CPOE (p< 0.001). The use of CPOE decreased the prescription errors from 19% to 3% (p= 0.001), However, no differences were observed in the control ward (p<0.05). In addition, more errors occurred in the morning shift (p< 0.001). Conclusion: In general, the use of CPOE significantly reduced the prescription errors. Nonetheless, more caution should be exercised in the use of this system, and its deficiencies should be resolved. Furthermore, it is recommended that CPOE be used to improve the quality of delivered services in hospitals. PMID:29445698

  6. The impact of computerized physician order entry on prescription orders: A quasi-experimental study in Iran.

    Science.gov (United States)

    Khammarnia, Mohammad; Sharifian, Roxana; Zand, Farid; Barati, Omid; Keshtkaran, Ali; Sabetian, Golnar; Shahrokh, Nasim; Setoodezadeh, Fatemeh

    2017-01-01

    Background: One way to reduce medical errors associated with physician orders is computerized physician order entry (CPOE) software. This study was conducted to compare prescription orders between 2 groups before and after CPOE implementation in a hospital. Methods: We conducted a before-after prospective study in 2 intensive care unit (ICU) wards (as intervention and control wards) in the largest tertiary public hospital in South of Iran during 2014 and 2016. All prescription orders were validated by a clinical pharmacist and an ICU physician. The rates of ordering the errors in medical orders were compared before (manual ordering) and after implementation of the CPOE. A standard checklist was used for data collection. For the data analysis, SPSS Version 21, descriptive statistics, and analytical tests such as McNemar, chi-square, and logistic regression were used. Results: The CPOE significantly decreased 2 types of errors, illegible orders and lack of writing the drug form, in the intervention ward compared to the control ward (p< 0.05); however, the 2 errors increased due to the defect in the CPOE (p< 0.001). The use of CPOE decreased the prescription errors from 19% to 3% (p= 0.001), However, no differences were observed in the control ward (p<0.05). In addition, more errors occurred in the morning shift (p< 0.001). Conclusion: In general, the use of CPOE significantly reduced the prescription errors. Nonetheless, more caution should be exercised in the use of this system, and its deficiencies should be resolved. Furthermore, it is recommended that CPOE be used to improve the quality of delivered services in hospitals.

  7. Value of the computerized axial tomography for early diagnosis of cranio cerebral trauma

    International Nuclear Information System (INIS)

    Rodriguez Cheong, Maricel; Dosouto Infante, Vivian; Rosales Fargie, Yamile

    2010-01-01

    A descriptive and cross-sectional study was conducted in 62 patients with cranio cerebral trauma admitted to 'Saturnino Lora' Provincial Teaching Hospital of Santiago de Cuba, from January 2005 to May 2006, in whom computerized axial tomography indicated at the emergency room was performed with the purpose of evaluating the effectiveness of this radiographic technique for early diagnosis of the injury. In the case material there was neither association between the source and imaging results, nor between the age and sex. The main clinical manifestations were vomiting, headache and motor deficit as well as frontal location, intraparenchymatous hematoma (the latter as the most common image finding) and the hyperdense area as tomographic pattern. The survival was of 91,9%

  8. Computed tomographic angiography study of the relationship between the lingual artery and lingual markers in patients with obstructive sleep apnoea

    Energy Technology Data Exchange (ETDEWEB)

    Hou, T.-N., E-mail: dr-htn@hotmail.co [Department of Otolaryngology Head and Neck Surgery, Affiliated SIR RUN RUN SHAW Hospital, Zhejiang University, Hangzhou 310016 (China); Zhou, L.-N.; Hu, H.-J. [Department of Otolaryngology Head and Neck Surgery, Affiliated SIR RUN RUN SHAW Hospital, Zhejiang University, Hangzhou 310016 (China)

    2011-06-15

    Aim: To determine the relationship between the lingual artery and lingual markers for preoperative evaluation of the lingual artery in patients with obstructive sleep apnoea/hypopnoea syndrome (OSAHS). Methods: A 16-section computed tomographic angiography (CTA) of the lingual artery was performed in 87 inpatient cases with OSAHS, from December 2007 to May 2009. The course of the lingual artery and the anatomic relationship between the lingual artery and the lingual markers were analyzed using CTA imaging. Results: The course of the lingual artery with the tongue in a resting position was similar to that of the Big Dipper constellation (Plough) in the sagittal view of CTA imaging. The first segment of the lingual artery declined approximately 19.27 {+-} 5.24 mm, the middle segment of the lingual artery was forward approximately 19.30 {+-} 6.79 mm, and the ascending segment of the lingual artery rose approximately 52.49 {+-} 10.98 mm. The entry point where the lingual artery entered into the tongue was adjacent to the tip of the greater horn of the hyoid bone. The relationship between the second segment of the lingual artery and the greater horn of the hyoid bone was relatively steady with the tongue in whatever position. The interval between the bilateral greater horn of the hyoid bone equalled that between the bilateral lingual arteries. Conclusions: Recognizing some lingual markers in the patients with OSAHS, such as the greater horn of the hyoid bone, foramen cecum, circumvallate papilla, lingual vein and tongue midline, may facilitate the surgeon's ability to define the course of the lingual artery accurately in the treatment of OSAHS.

  9. Tiny staining spots in liver cirrhosis associated with HCV infection observed by computed tomographic hepatic arteriography. Follow-up study

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiyama, Tomoya; Terasaki, Shuichi; Kaneko, Shuichi; Kaji, Kyosuke; Kobayashi, Kenichi; Matsui, Osamu [Kanazawa Univ. (Japan). Hospital

    2002-10-01

    It is important to distinguish small lesions with increased arterial perfusion observed by computed tomographic arteriography (CT-A) from hepatocellular carcinoma (HCC). However, the clinical characteristics and prognosis of such lesions have not been clarified. We retrospectively examined 200 patients with cirrhosis related to hepatitis C virus (HCV) infection who had undergone both CT-A and CT arterioportography between 1995 and 1998, and found 80 tiny staining spots (TSS)s, with a diameter of 5-10 mm, by CT-A (35 patients). The mean TSS observation period was 29.0 months. If the major axis was larger than 10 mm and showed a 1.5-fold or more increase, the lesion was regarded as tumor growth (TG). The TSS lesions were divided into two groups according to whether the patient had or did not have HCC. The prognosis of TSS was classified into three groups; HCC-suspected group, nontumor group, and unclassified group, in which TG was negative although transcatheter arterial embolization (TAE) had been performed. Of the 40 TSSs in 14 patients without HCC, 2 (5%) were suspected as HCC. Of the 40 TSSs in 21 patients with HCC, 13 (32.5%) were suspected as HCC. There were no significant differences in the size, position, and morphology of TSSs among the three prognostic groups. Of the 7 TSSs with a high signal intensity on T2-weighted magnetic resonance (MR) images, 5 were in the HCC-suspected group. We recommend early treatment of TSSs accompanying HCC or showing features of malignancy at the imaging workup. (author)

  10. IMPACTS OF BOVINE TRACEABILITY IMPLANTATION IN COMPUTERIZED RURAL COMPANIES: CASE STUDIES

    Directory of Open Access Journals (Sweden)

    Henri Cócaro

    2008-02-01

    Full Text Available This study looked into evaluating the impacts that the adhesion to the bovine traceability caused in four agricultural companies that adopted or used ITs for tracked herd management. After comparing the case studies it was concluded that the adhesion to traceability caused the adoption of ITs, mainly of the management and traceability system for beef cattle and the electronic scale; the zoo technical changes that happened were, the individual identification of the animals, the control of animal stock and the possibility to determine performance and reproductive indexes; the management changes that happened were the development of new controls by filing the animal identification document (DIA, the documentation of the purchase, use and exit of inputs (nutritional and sanitarian, and the documentation of animal movements. It was not verified the return of managerial or zoo technical information by SISBOV that aided the companies in their decision-taking process.

  11. Nursing students learning the pharmacology of diabetes mellitus with complexity-based computerized models: A quasi-experimental study.

    Science.gov (United States)

    Dubovi, Ilana; Dagan, Efrat; Sader Mazbar, Ola; Nassar, Laila; Levy, Sharona T

    2018-02-01

    Pharmacology is a crucial component of medications administration in nursing, yet nursing students generally find it difficult and self-rate their pharmacology skills as low. To evaluate nursing students learning pharmacology with the Pharmacology Inter-Leaved Learning-Cells environment, a novel approach to modeling biochemical interactions using a multiscale, computer-based model with a complexity perspective based on a small set of entities and simple rules. This environment represents molecules, organelles and cells to enhance the understanding of cellular processes, and combines these cells at a higher scale to obtain whole-body interactions. Sophomore nursing students who learned the pharmacology of diabetes mellitus with the Pharmacology Inter-Leaved Learning-Cells environment (experimental group; n=94) or via a lecture-based curriculum (comparison group; n=54). A quasi-experimental pre- and post-test design was conducted. The Pharmacology-Diabetes-Mellitus questionnaire and the course's final exam were used to evaluate students' knowledge of the pharmacology of diabetes mellitus. Conceptual learning was significantly higher for the experimental than for the comparison group for the course final exam scores (unpaired t=-3.8, pLearning with complexity-based computerized models is highly effective and enhances the understanding of moving between micro and macro levels of the biochemical phenomena, this is then related to better understanding of medication actions. Moreover, the Pharmacology Inter-Leaved Learning-Cells approach provides a more general reasoning scheme for biochemical processes, which enhances pharmacology learning beyond the specific topic learned. The present study implies that deeper understanding of pharmacology will support nursing students' clinical decisions and empower their proficiency in medications administration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. The efficacy of computerized alcohol intervention tailored to drinking motives among college students: a quasi-experimental pilot study.

    Science.gov (United States)

    Canale, Natale; Vieno, Alessio; Santinello, Massimo; Chieco, Francesca; Andriolo, Stefano

    2015-03-01

    Although motivational processes may influence the intervention effects and help prevention programmes identify students at great risk for alcohol-related problems, no computerized alcohol intervention has yet to be tailored to drinking motives. To describe the development and initial pilot testing of a computer-delivered intervention tailored to drinking motives, to prevent alcohol abuse and its adverse consequences among university students in general and among baseline hazardous drinkers specifically. 124 college students attending a public university in northeastern Italy participated in this study in October of 2012 (89.2% female- mean age = 21.64-34% baseline hazardous drinkers). Two classes (one undergraduate, one graduate) were assigned to one of two conditions: intervention and control group. Both groups received profile-specific feedback and then the intervention group received profile-specific online training for 4 weeks. This profile was based on their risk type (high-low) and drinking motives (enhancement-social-conformity-coping). Controlling for corresponding baseline alcohol measures, analyses showed a significant interaction between intervention condition and hazardous drinkers at baseline. For hazardous drinkers at baseline, the alcohol intervention results showed a significant decrease in frequency and quantity of alcohol use at follow-up, while no difference was observed between intervention conditions for non-hazardous drinkers at baseline. The results suggest that hazardous drinkers (college students) who completed the specific training and received personalized feedback seemed to do better on frequency and quantity of alcohol use than hazardous drinkers (college students) who received only personalized feedback. These results seem to provide support for a larger trial of the intervention and for more appropriate evaluations.

  13. In vitro studies reveal antiurolithic effect of Terminalia arjuna using quantitative morphological information from computerized microscopy

    Directory of Open Access Journals (Sweden)

    A. Mittal

    2015-10-01

    Full Text Available ABSTRACT Purpose: For most cases, urolithiasis is a condition where excessive oxalate is present in the urine. Many reports have documented free radical generation followed by hyperoxaluria as a consequence of which calcium oxalate (CaOx deposition occurs in the kidney tissue. The present study is aimed to exam the antilithiatic potency of the aqueous extract (AE of Terminalia arjuna (T. arjuna. Materials and Methods: The antilithiatic activity of Terminalia arjuna was investigated in vitro nucleation, aggregation and growth of the CaOx crystals as well as the morphology of CaOx crystals using the inbuilt software ‘Image-Pro Plus 7.0’ of Olympus upright microscope (BX53. Antioxidant activity of AE of Terminalia arjuna bark was also determined in vitro. Results: Terminalia arjuna extract exhibited a concentration dependent inhibition of nucleation and aggregation of CaOx crystals. The AE of Terminalia arjuna bark also inhibited the growth of CaOx crystals. At the same time, the AE also modified the morphology of CaOx crystals from hexagonal to spherical shape with increasing concentrations of AE and reduced the dimensions such as area, perimeter, length and width of CaOx crystals in a dose dependent manner. Also, the Terminalia arjuna AE scavenged the DPPH (2, 2-diphenyl-1-picrylhydrazyl radicals with an IC50 at 13.1µg/mL. Conclusions: The study suggests that Terminalia arjuna bark has the potential to scavenge DPPH radicals and inhibit CaOx crystallization in vitro. In the light of these studies, Terminalia arjuna can be regarded as a promising candidate from natural plant sources of antilithiatic and antioxidant activity with high value.

  14. A study using computerized tomography in the clinical practice of temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Yamamoto, Kunimitsu

    1982-01-01

    The author has studied about analysis of clinical data and CT findings examined conventional method for 50 cases of temporal lobe epilepsy and how to assess the foci of temporal lobe by CT. According to the examination of conventional neuroradiologic technique and routine work of CT for temporal lobe epilepsy, an extreme space occuping lesions were detected and marked cerebral atrophy, low density area in temporal lobe were found out, but, most of them were not able to detect foci of the temporal lobe and yet, the study of CT number based on the print out data did not give any precise informations about epileptogenic lesions of temporal lobe epilepsy. The method of reversed axial section CT was designed to photograph inferior horn of lateral ventricles with the purpose to delineate the hippocampus and amygdata, and precise pictures from autopsy brain and clinical cases were obtained by that method about scanning angle of reversed axial section CT, various angles are made an experiment on scanning, such as reversed 15 0 , 20 0 , 25 0 , 30 0 , 35 0 . Among them, it is proved that the reversed angle of almost 25 0 is most suitable to delineate mesial temporal structure, so as to say, foci of the temporal lobe. (J.P.N.)

  15. Study of computerized spirometric parameters of traffic police personnel of Saurashtra region, Gujarat, India.

    Science.gov (United States)

    Makwana, Amit H; Solanki, Jayesh D; Gokhale, Pradnya A; Mehta, Hemant B; Shah, Chinmay J; Gadhavi, Bhakti P

    2015-01-01

    Air pollution due to road traffic is a serious health hazard and air quality crisis in cities is mainly due to vehicular emission. Thus the persons who are continuously exposed are at an increased risk. The study was carried out to evaluate the extent of impairment in lung function in traffic police personnel compared to matched unexposed control group. A cross-sectional study was conducted to measure the spirometric parameters of 100 traffic police personnel, aged 20-55 years, working in Saurashtra region, as compared to matched control group, consisting of 100 unexposed males. Measurement of lung volumes and capacities was done with SPIROEXCEL. The statistical analysis was carried out with Graph pad instat 3. Traffic police personnel had significantly declined forced vital capacity (FVC), forced expiratory volume in one second (FEV 1), slow vital capacity (SVC) and maximum voluntary ventilation (MVV) when compared with predictive normal values, which is probably due to exposure to vehicular exhaust. Comparison of test values between groups showed significantly reduced FVC, MVV and increased FEV1/FVC ratio and insignificantly declined FEV1 and SVC in cases as compared to controls. Traffic personnel with longer duration of exposure showed significantly reduced lung functions than those with shorter duration. Smokers showed lower test values as compared to non-smokers with significance only in unexposed group. The effect of pollution by vehicular exhausts may be responsible for these pulmonary function impairments and traffic police personnel should be offered personal protective or preventive measures.

  16. Study of computerized spirometric parameters of traffic police personnel of Saurashtra region, Gujarat, India

    Directory of Open Access Journals (Sweden)

    Amit H Makwana

    2015-01-01

    Full Text Available Background and Objectives: Air pollution due to road traffic is a serious health hazard and air quality crisis in cities is mainly due to vehicular emission. Thus the persons who are continuously exposed are at an increased risk. The study was carried out to evaluate the extent of impairment in lung function in traffic police personnel compared to matched unexposed control group. Materials and Methods: A cross-sectional study was conducted to measure the spirometric parameters of 100 traffic police personnel, aged 20-55 years, working in Saurashtra region, as compared to matched control group, consisting of 100 unexposed males. Measurement of lung volumes and capacities was done with SPIROEXCEL. The statistical analysis was carried out with Graph pad instat 3. Results: Traffic police personnel had significantly declined forced vital capacity (FVC, forced expiratory volume in one second (FEV 1, slow vital capacity (SVC and maximum voluntary ventilation (MVV when compared with predictive normal values, which is probably due to exposure to vehicular exhaust. Comparison of test values between groups showed significantly reduced FVC, MVV and increased FEV1/FVC ratio and insignificantly declined FEV1 and SVC in cases as compared to controls. Traffic personnel with longer duration of exposure showed significantly reduced lung functions than those with shorter duration. Smokers showed lower test values as compared to non-smokers with significance only in unexposed group. Conclusion: The effect of pollution by vehicular exhausts may be responsible for these pulmonary function impairments and traffic police personnel should be offered personal protective or preventive measures.

  17. Studies of the correlations between morphological brain changes on MRI and computerized EEG changes in schizophrenics

    International Nuclear Information System (INIS)

    Takeuchi, Kouzou

    1992-01-01

    Twenty eight schizophrenic patients, who ranged in age from 21 to 39 years with a mean of 30.2, and 21 age- and sex-matched normal volunteers were studied by magnetic resonance (MR) imaging and electroencephalography (EEG). ALl subjects were given informed consent prior to the present study. They were all right-handed. Schizophrenic patients showed a significantly larger ventricular brain ratio (VBR) on the axial and coronal planes as compared with the control. The bilateral anterior horns, left body, left posterior horn of the lateral ventricle and the third ventricle were significantly larger in schizophrenic patients than the control. The middle half of the corpus callosum was smaller in schizophrenic patients than the control. Schizophrenia was more likely associated not only with delta and theta activities in the centro-parieto-occipital regions but also with beta 1 and beta 2 activities in the front-central regions. In schizophrenic patients, however, alpha 2 activity was markedly decreased in all regions. There were significant positive correlations between the total scores for brief psychiatric rating scale (BPRS) and the areas of the left anterior and posterior horns of the lateral ventricle. The total BPRS scores positively correlated with the area of the third ventricle. In addition, positive correlations were significant between delata activity and the area of the left anterior horn of the lateral ventricle, between delta activity and the area of the third ventricle, and between beta 1 activity and the area of left posteior horn of the lateral ventricle. These results suggest that a dilated third ventricle is associated with electrophysiological brain pathology and psychopathology in schizophrenic patients. (N.K.) 76 refs

  18. A comparative study of computerized tomograms and neuropathological findings in cerebrovascular diseases

    International Nuclear Information System (INIS)

    Tohgi, Hideo; Mochizuki, Hiroshi; Yamanouchi, Hiroshi; Iio, Masahiro; Yamada, Hideo

    1979-01-01

    The reliability of computed tomography (CT) in the diagnosis of cerebrovascular diseases was studied by comparing CT images and neuropathological findings in 38 autopsied cases. Our special concern was directed toward several factors which caused false positive and false negative results in CT: the size and location of lesions, and the interval between the onset of the disease and the time of CT studies. Infarctions smaller than 5 mm should be interpreted as such with great care, because only 32.1% of them could be detected in CT, and 81.0% of small low density areas supposed to be small infarctions in CT films proved to be false positive in postmortem examination. 41.9% of middle-sized infarctions were detected in CT and 40.9% of middle-sized low density areas were false positive. Most of false positive low density areas appeared on the surface of the cerebrum where deep sulci join, or in the white matter anterior to the anterior horn or posterior to the posterior horn of the lateral ventricles. The possibility of false positive findings became far less, when the number of slices showing low density areas increased. All of the large infarctions were detected in CT. However, immediately after stroke they did not stand out as low density areas. In such cases, the decrease of cerebral sulci due to brain edema and signs of compression in the ventricular system could be the clues to make the diagnosis of large infarctions. The diagnosis of hemorrhagic infarctions was often difficult. Cerebral bleeding could be diagnosed easily by CT in its early period. However, old hematomas which rapidly resolved and became shrunken, could hardly be identified in CT. (author)

  19. Idiopathic dilated cardiomyopathy: computerized anatomic study of relashionship between septal and free left ventricle wall.

    Science.gov (United States)

    Juliani, Paulo Sérgio; Costa, Eder França da; Correia, Aristides Tadeu; Monteiro, Rosangela; Jatene, Fabio Biscegli

    2014-01-01

    A feature of dilated cardiomyopathy is the deformation of ventricular cavity, which contributes to systolic dysfunction. Few studies have evaluated this deformation bearing in mind ventricular regions and segments of the ventricle, which could reveal important details of the remodeling process, supporting a better understanding of its role in functional impairment and the development of new therapeutic strategies. To evaluate if, in basal, equatorial and apical regions, increased internal transverse perimeter of left ventricle in idiopathic dilated cardiomyopathy occurs proportionally between the septal and non-septal segment. We performed an anatomical study with 28 adult hearts from human cadavers. One group consisted of 18 hearts with idiopathic dilated cardiomyopathy and another group with 10 normal hearts. After lamination and left ventricle digital image capture, in three different regions (base, equator and apex), the transversal internal perimeter of left ventricle was divided into two segments: septal and not septal. These segments were measured by proper software. It was established an index of proportionality between these segments, called septal and non-septal segment index. Then we determined whether this index was the same in both groups. Among patients with normal hearts and idiopathic dilated cardiomyopathy, the index of proportionality between the two segments (septal and non-septal) showed no significant difference in the three regions analyzed. The comparison results of the indices NSS/SS among normal and enlarged hearts were respectively: in base 1.99 versus 1.86 (P=0.46), in equator 2.22 versus 2.18 (P=0.79) and in apex 2.96 versus 3.56 (P=0.11). In the idiopathic dilated cardiomyopathy, the transversal dilatation of left ventricular internal perimeter occurs proportionally between the segments corresponding to the septum and free wall at the basal, equatorial and apical regions of this chamber.

  20. A clinical study on the detection of epileptogenic foci in epileptics using computerized tomography

    International Nuclear Information System (INIS)

    Kobayashi, Eiki

    1979-01-01

    EEG findings of partial epilepsy were classified as localized abnormality in 65%, diffuse abnormality in 21% and borderline in 14% of cases. Abnormal CT findings of partial epilepsy were observed in 37% of the patients. These findings consisted of localized abnormalities in 68% and diffuse abnormalities in 32% of cases, and these were classified into 4 groups; localized or diffuse cerebral atrophy, localized low density, localized or multiple disseminated high density (calicification) and localized enhancement with contrast medium. Abnormal CT findings were more frequent in the cases of onset under 10 years of age. The incidence of CT abnormality seemed to be higher in the cases with continuous, especially continuous localized EEG abnormality, than in the cases with the other types of EEG abnormality. In the 16 cases out of 37 with CT abnormality, that is in 43% of the cases, the location of abnormal CT findings was coincident with that of their EEG foci. And epileptogenic foci were verified in 16% of all the patients. Cerebral angiography showed various and precise vascular abnormalities in 82% of these cases. And the CT abnormal group of patients was inferred to have considerable histopathological changes in the epileptogenic foci, but the group with normal CT images did not yield such significant findings. In comparison with partial epilepsy, 100 cases of generalized epilepsy were studied, and CT abnormalities were observed only in 16% of cases. Diffuse cerebral atrophy was naturally the most frequent kind of abnormal finding, and localized abnormalities were not so frequent in generalized epilepsy. (Kanao, N.)

  1. The study of optimization on process parameters of high-accuracy computerized numerical control polishing

    Science.gov (United States)

    Huang, Wei-Ren; Huang, Shih-Pu; Tsai, Tsung-Yueh; Lin, Yi-Jyun; Yu, Zong-Ru; Kuo, Ching-Hsiang; Hsu, Wei-Yao; Young, Hong-Tsu

    2017-09-01

    Spherical lenses lead to forming spherical aberration and reduced optical performance. Consequently, in practice optical system shall apply a combination of spherical lenses for aberration correction. Thus, the volume of the optical system increased. In modern optical systems, aspherical lenses have been widely used because of their high optical performance with less optical components. However, aspherical surfaces cannot be fabricated by traditional full aperture polishing process due to their varying curvature. Sub-aperture computer numerical control (CNC) polishing is adopted for aspherical surface fabrication in recent years. By using CNC polishing process, mid-spatial frequency (MSF) error is normally accompanied during this process. And the MSF surface texture of optics decreases the optical performance for high precision optical system, especially for short-wavelength applications. Based on a bonnet polishing CNC machine, this study focuses on the relationship between MSF surface texture and CNC polishing parameters, which include feed rate, head speed, track spacing and path direction. The power spectral density (PSD) analysis is used to judge the MSF level caused by those polishing parameters. The test results show that controlling the removal depth of single polishing path, through the feed rate, and without same direction polishing path for higher total removal depth can efficiently reduce the MSF error. To verify the optical polishing parameters, we divided a correction polishing process to several polishing runs with different direction polishing paths. Compare to one shot polishing run, multi-direction path polishing plan could produce better surface quality on the optics.

  2. Development of the human lateral geniculate nucleus: A morphometric and computerized 3D-reconstruction study.

    Science.gov (United States)

    Yamaguchi, Katsuyuki

    2018-04-04

    The lateral geniculate nucleus (LGN) is the major relay center of the visual pathway in humans. There are few quantitative data on the morphology of LGN in prenatal infants. In this study, using serial brain sections, the author investigated the morphology of this nucleus during the second half of fetal period. Eleven human brains were obtained at routine autopsy from preterm infants aged 20-39 postmenstrual weeks. After fixation, the brain was embedded en bloc in celloidin and cut serially at 30 μm in the horizontal plane. The sections were stained at regular intervals using the Klüver-Barrera method. At 20-21 weeks, the long axis of LGN declined obliquely from the vertical to horizontal plane, while a deep groove was noted on the ventro-lateral surface of the superior half. At this time, an arcuate cell-sparse zone appeared in the dorso-medial region, indicating the beginning of lamination. From 25 weeks onwards, the magnocellular and parvocellular layers were distinguishable, and the characteristic six-layered structure was recognized. The magnocellular layer covered most of the dorsal surface, and parts of the medial, lateral, and inferior surfaces but not the ventral and superior surfaces. Nuclear volume increased exponentially with age during 20-39 weeks, while the mean neuronal profile area increased linearly during 25-39 weeks. Human LGN develops a deep groove on the ventro-lateral surface at around mid-gestation, when the initial lamination is recognized in the prospective magnocellular layer. Thereafter, the nuclear volume increases with age in an exponential function. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. A study on the clinical utilization of cranial computerized tomography: reasons and costs

    International Nuclear Information System (INIS)

    Oliveira, A.T.R. de

    1992-01-01

    It was reviewed a series of 2860 cerebral computed tomography (CCT) in order to compare the main reasons at referral to investigation with the CCT results and the costs with normal and abnormal CCT. It was also studied the age and sex of the patients. Data were collected from one out of three diagnostic centers in Salvador, Brasil, for a three years period. The 2860 CCT exclude all investigation carried out for the follow-up of a previously diagnosed abnormality. CCT abnormalities were detected in 1152 (40.3%). The following reasons showed the highest proportion of abnormal CCT, for males and females respectively: demential syndrome (91.7 and 83.3%); cerebrovascular accidents (85.1 and 73.6%); infectious and parasital diseases (76.5 and 78.6%); tumors (65.8 and 55.4%); and head injuries, 63.6% for males. In the female group, 65.0% of the CCT were normal, in a range of 65.0 to 80.0% for the age groups under 54 years old. In the male group, the highest proportion of normal CCT was found in the age groups: 25-34 (68.4%), <15 (62.9%) and 35-44 (62.7%). The most common reasons for normal CCT for males and females were: headache (81.3 and 87.5%); dizziness/vertigo (79.3 and 78.6%); seizures (67.3 and 70.0%); psycho motor deficiency (72.0 and 67.7%) and endocrine disorders, 75.0% for each sex. The highest proportion of normal CCT (65.3%) was requested by medical 'convenios'. The cost with normal CCT reached US$ 565,225 and with the abnormal ones, US$ 381,247. Cost with normal CCT were 2,2 higher for medical convenios as compared to those of the National Institute of Security requests and 2.8 more than those of private medicine. (author)

  4. Imagery Scripts and a Computerized Subtraction Stress Task Both Induce Stress in Methamphetamine Users: A Controlled Laboratory Study

    Directory of Open Access Journals (Sweden)

    Kathleen J. Garrison

    2010-01-01

    Full Text Available Patients treated for methamphetamine (MA dependence have a high rate of relapse, and stress is thought to play a key role. We sought to develop a computerized procedure for experimentally inducing stress in MA users. In a within-subjects design, we compared a computerized subtraction stress task (SST to personalized stress-imagery scripts and a control condition (neutral imagery in 9 former MA users, recruited in San Francisco in 2006–2007. We assessed blood hormone levels, anxiety and craving for MA on visual analog scales, and the Positive and Negative Affect Schedule and made linear mixed-effects models to analyze the results. Both the SST and stress scripts were effective in inducing self-report markers of stress in MA users. Because the SST is easily reproducible and requires less time of staff and participants, it may be a useful alternative for measuring stress reactivity in drug users.

  5. Studies and research concerning BNFP: computerized nuclear materials control and accounting system development evaluation report, FY 1978

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, J M; Ehinger, M H; Joseph, C; Madeen, M L

    1978-10-01

    Development work on a computerized system for nuclear materials control and accounting in a nuclear fuel reprocessing plant is described and evaluated. Hardware and software were installed and tested to demonstrate key measurement, measurement control, and accounting requirements at accountability input/output points using natural uranium. The demonstration included a remote data acquisition system which interfaces process and special instrumentation to a cenral processing unit.

  6. A study of magnification effect to precision of computerized diameter measurement of a 3-mm vessel phantom in cineangiograms

    International Nuclear Information System (INIS)

    Yanagihara, Yoshio; Sugahara, Tetsuo; Sugimoto, Naozou; Fukunishi, Yasunobu.

    1994-01-01

    To estimate influence of magnification on digitizing to Precision of computerized measurement of coronary vessel diameter, the two measurement methods, i.e., a combined filter and Entropy filter, were applied to magnified images (x1-x6) of cineangiograms radiographed for a 3-mm vessel phantom. In conclusion, the desirable precision in clinical use, we thought, was obtainable at the magnification of x3 to x4. (author)

  7. NIRS Study of the Effects of Computerized Brain Training Games for Cognitive Rehabilitation of Major Depressive Disorder Patients in Remission: A Pilot Study.

    Science.gov (United States)

    Payzieva, Shaira; Maxmudova, D

    2014-01-01

    We used functional Near-Infrared Spectroscopy (fNIRS) to estimate brain activity in Major Depressive Disorder (MDD) patients (in remission), while they played a computerized brain training games for cognitive rehabilitation. MDD is characterized by marked deterioration in affect as well as significant impairment in cognitive function. It was found, that depressed patients showed long-lasting impaired cognitive performance on cognitive demanding tasks despite significant improvement in the depression symptoms. Previous studies have shown that video games can improve cognitive functions. But assessment was made only with cognitive tests. The main objective of this research was to study the effects of brain training games on cognitive functions of MDD patients in remission with objective instrumental NIRS method. Tissue oxygen saturation (StO2) and absolute concentrations of oxyhemoglobin ([O2Hb]), deoxyhemoglobin ([HHb]) and total hemoglobin ([tHb]) were measured by functional near-infrared spectroscopy (fNIRS) - Oxyprem (BORL, Zurich, Switzerland). Preliminary results are discussed.

  8. Tomographic multiphase flow measurement

    International Nuclear Information System (INIS)

    Sætre, C.; Johansen, G.A.; Tjugum, S.A.

    2012-01-01

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: ► Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. ► High-speed gamma ray tomograph as reference for the flow pattern and gas fraction. ► Dual modality

  9. Tomographic multiphase flow measurement

    Energy Technology Data Exchange (ETDEWEB)

    Saetre, C., E-mail: camilla@ift.uib.no [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Johansen, G.A. [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Tjugum, S.A. [Michelsen Centre for Industrial Measurement Science and Technology (Norway); Roxar Flow Measurement, Bergen (Norway)

    2012-07-15

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: Black-Right-Pointing-Pointer Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. Black-Right-Pointing-Pointer High-speed gamma ray tomograph as reference for the flow

  10. Impact of a computerized system for evidence-based diabetes care on completeness of records: a before–after study

    Directory of Open Access Journals (Sweden)

    Roshanov Pavel S

    2012-07-01

    Full Text Available Abstract Background Physicians practicing in ambulatory care are adopting electronic health record (EHR systems. Governments promote this adoption with financial incentives, some hinged on improvements in care. These systems can improve care but most demonstrations of successful systems come from a few highly computerized academic environments. Those findings may not be generalizable to typical ambulatory settings, where evidence of success is largely anecdotal, with little or no use of rigorous methods. The purpose of our pilot study was to evaluate the impact of a diabetes specific chronic disease management system (CDMS on recording of information pertinent to guideline-concordant diabetes care and to plan for larger, more conclusive studies. Methods Using a before–after study design we analyzed the medical record of approximately 10 patients from each of 3 diabetes specialists (total = 31 who were seen both before and after the implementation of a CDMS. We used a checklist of key clinical data to compare the completeness of information recorded in the CDMS record to both the clinical note sent to the primary care physician based on that same encounter and the clinical note sent to the primary care physician based on the visit that occurred prior to the implementation of the CDMS, accounting for provider effects with Generalized Estimating Equations. Results The CDMS record outperformed by a substantial margin dictated notes created for the same encounter. Only 10.1% (95% CI, 7.7% to 12.3% of the clinically important data were missing from the CDMS chart compared to 25.8% (95% CI, 20.5% to 31.1% from the clinical note prepared at the time (p p  Conclusions The CDMS chart captured information important for the management of diabetes more often than dictated notes created with or without its use but we were unable to detect a difference in completeness between notes dictated in CDMS-associated and usual-care encounters. Our sample of

  11. Image interface in Java for tomographic reconstruction in nuclear medicine

    International Nuclear Information System (INIS)

    Andrade, M.A.; Silva, A.M. Marques da

    2004-01-01

    The aim of this study is to implement a software for tomographic reconstruction of SPECT data from Nuclear Medicine with a flexible interface design, cross-platform, written in Java. Validation tests were performed based on SPECT simulated data. The results showed that the implemented algorithms and filters agree with the theoretical context. We intend to extend the system by implementing additional tomographic reconstruction techniques and Java threads, in order to provide simultaneously image processing. (author)

  12. What hinders the uptake of computerized decision support systems in hospitals? A qualitative study and framework for implementation.

    Science.gov (United States)

    Liberati, Elisa G; Ruggiero, Francesca; Galuppo, Laura; Gorli, Mara; González-Lorenzo, Marien; Maraldi, Marco; Ruggieri, Pietro; Polo Friz, Hernan; Scaratti, Giuseppe; Kwag, Koren H; Vespignani, Roberto; Moja, Lorenzo

    2017-09-15

    Advanced Computerized Decision Support Systems (CDSSs) assist clinicians in their decision-making process, generating recommendations based on up-to-date scientific evidence. Although this technology has the potential to improve the quality of patient care, its mere provision does not guarantee uptake: even where CDSSs are available, clinicians often fail to adopt their recommendations. This study examines the barriers and facilitators to the uptake of an evidence-based CDSS as perceived by diverse health professionals in hospitals at different stages of CDSS adoption. Qualitative study conducted as part of a series of randomized controlled trials of CDSSs. The sample includes two hospitals using a CDSS and two hospitals that aim to adopt a CDSS in the future. We interviewed physicians, nurses, information technology staff, and members of the boards of directors (n = 30). We used a constant comparative approach to develop a framework for guiding implementation. We identified six clusters of experiences of, and attitudes towards CDSSs, which we label as "positions." The six positions represent a gradient of acquisition of control over CDSSs (from low to high) and are characterized by different types of barriers to CDSS uptake. The most severe barriers (prevalent in the first positions) include clinicians' perception that the CDSSs may reduce their professional autonomy or may be used against them in the event of medical-legal controversies. Moving towards the last positions, these barriers are substituted by technical and usability problems related to the technology interface. When all barriers are overcome, CDSSs are perceived as a working tool at the service of its users, integrating clinicians' reasoning and fostering organizational learning. Barriers and facilitators to the use of CDSSs are dynamic and may exist prior to their introduction in clinical contexts; providing a static list of obstacles and facilitators, irrespective of the specific implementation

  13. Organization-wide adoption of computerized provider order entry systems: a study based on diffusion of innovations theory

    Directory of Open Access Journals (Sweden)

    Timpka Toomas

    2009-12-01

    Full Text Available Abstract Background Computerized provider order entry (CPOE systems have been introduced to reduce medication errors, increase safety, improve work-flow efficiency, and increase medical service quality at the moment of prescription. Making the impact of CPOE systems more observable may facilitate their adoption by users. We set out to examine factors associated with the adoption of a CPOE system for inter-organizational and intra-organizational care. Methods The diffusion of innovation theory was used to understand physicians' and nurses' attitudes and thoughts about implementation and use of the CPOE system. Two online survey questionnaires were distributed to all physicians and nurses using a CPOE system in county-wide healthcare organizations. The number of complete questionnaires analyzed was 134 from 200 nurses (67.0% and 176 from 741 physicians (23.8%. Data were analyzed using descriptive-analytical statistical methods. Results More nurses (56.7% than physicians (31.3% stated that the CPOE system introduction had worked well in their clinical setting (P P = P = 0.041. We found that in particular the received relative advantages of the CPOE system were estimated to be significantly (P P Conclusions Qualifications for CPOE adoption as defined by three attributes of diffusion of innovation theory were not satisfied in the study setting. CPOE systems are introduced as a response to the present limitations in paper-based systems. In consequence, user expectations are often high on their relative advantages as well as on a low level of complexity. Building CPOE systems therefore requires designs that can provide rather important additional advantages, e.g. by preventing prescription errors and ultimately improving patient safety and safety of clinical work. The decision-making process leading to the implementation and use of CPOE systems in healthcare therefore has to be improved. As any change in health service settings usually faces resistance

  14. Bone density of defects treated with lyophilized amniotic membrane versus colagen membrane: a tomographic and histomorfogenic study in a rabbi´s femur.

    Directory of Open Access Journals (Sweden)

    Liz Ríos

    2014-09-01

    Full Text Available The aim of this study was to compare the bone density of bone defects treated with lyophilizated amniotic membrane (LAM and collagen Membrane (CM, at 3 and 5 weeks. Two bone defects of 4mm in diameter and 6mm deep were created in left distal femoral diaphysis of New Zealand rabbits (n=12. The animals were randomly divided into 2 groups. One of the defects was covered with lyophilized amniotic membrane (Rosa Chambergo Tissue Bank/National Institute of Child Health-IPEN, Lima, Peru or collagen Membrane (Dentium Co, Seoul, Korea. The second was left uncovered (NC. The rabbits were killed after 3 and 5 weeks (3 rabbits/period. The results showed a high bone density and repair of the defect by new bone. The tomographic study revealed that the bone density of the defects treated with LAM at 3 weeks was equivalent to the density obtained with CM and higher density compared with NC (p0.05. The results show that lyophilizated amniotic membrane provides bone density equal or higher to the collagen membrane.

  15. The use of stable xenon-enhanced computed tomographic studies of cerebral blood flow to define changes in cerebral carbon dioxide vasoresponsivity caused by a severe head injury.

    Science.gov (United States)

    Marion, D W; Bouma, G J

    1991-12-01

    Previous studies using the xenon-133 cerebral blood flow (CBF) method have documented the impairment of CO2 vasoresponsivity after a severe head injury, but only global values can be obtained reliably with this technique. We studied CO2 vasoresponsivity using the stable xenon-enhanced computed tomographic CBF method, which provided information about well-defined cortical regions and deep brain structures not available with the xenon-133 method. In 17 patients with admission Glasgow Coma Scale scores of 8 or less, hemispheric CO2 vasoresponsivity ranged from 1.3 to 8.5% per mm Hg change in partial CO2 pressure. Lobar, cerebellar, basal ganglia, and brain stem CO2 vasoresponsivity frequently varied from the mean global value by more than 25%. In all but one patient, local CO2 vasoresponsivity in one or more of these areas differed from the mean global value by more than 50%. The greatest variability occurred in patients with acute subdural hematomas and diffuse (bihemispheric) injuries. This variability in CO2 vasoresponsivity has important implications for the effective and safe management of intracranial hypertension that frequently accompanies severe head injury.

  16. Tomographic imaging system

    International Nuclear Information System (INIS)

    Hayakawa, T.; Horiba, I.; Kohno, H.; Nakaya, C.; Sekihara, K.; Shiono, H.; Tomura, T.; Yamamoto, S.; Yanaka, S.

    1980-01-01

    A tomographic imaging system comprising: irradiating means for irradating a cross-section of an object under consideration with radiation rays from plural directions; detector means for detecting the radiation rays transmitted through the cross-section of said object to produce an output signal; first memory means for storing the output signal of said detector means; and an image jreconstructing section for performing a convolution integral operation on the contents of said first memory means by means of a first weighting function to reconstruct a three-dimensional image of the cross-section of said object, said image reconstructing section including (I) second memory means for storing a second weighting function, said second weighting function being provided with a predetermined positive and negative (N-1)th order when the output signal of said detector means produced by the irradiation of the cross-section of said object from one of said plural directions is sampled by N points, the value of the (N-1)th order of said second weighting function being an integration of said first weighting function from the (N-1)th order to positive infinity and the value of -(N-1)th order of said second weighting function being an integration of said first weighting function from the -(N-1)th order to negative infinity, (II) control means for successively reading out the contents of said first and second memory means, and (III) operational means for performing multiplying and summing operations on the read-out contents of said first and second memory means, said operational means producing the product of the values fo the (N-1)th and -(N-1)th orders of said second weighting function and a component of the output signal of said detector means relating to the radiation rays free from the absorption thereof by said object

  17. Effects of peer social interaction on performance during computerized cognitive remediation therapy in patients with early course schizophrenia: A pilot study.

    Science.gov (United States)

    Sandoval, Luis R; González, Betzamel López; Stone, William S; Guimond, Synthia; Rivas, Cristina Torres; Sheynberg, David; Kuo, Susan S; Eack, Shaun; Keshavan, Matcheri S

    2017-09-04

    Recent studies show that computer-based training enhances cognition in schizophrenia; furthermore, socialization has also been found to improve cognitive functions. It is generally believed that non-social cognitive remediation using computer exercises would be a pre-requisite for therapeutic benefits from social cognitive training. However, it is also possible that social interaction by itself enhances non-social cognitive functions; this possibility has scarcely been explored in schizophrenia patients. This pilot study examined the effects of computer-based neurocognitive training, along with social interaction either with a peer (PSI) or without one (N-PSI). We hypothesized that PSI will enhance cognitive performance during computerized exercises in schizophrenia, as compared with N-PSI. Sixteen adult participants diagnosed with schizophrenia or schizoaffective disorder participating in an ongoing trial of Cognitive Enhancement Therapy completed several computerized neurocognitive remediation training sessions (the Orientation Remedial Module©, or ORM), either with a peer or without a peer. We observed a significant interaction between the effect of PSI and performance on the different cognitive exercises (p<0.05). More precisely, when patients performed the session with PSI, they demonstrated better cognitive performances than with N-PSI in the ORM exercise that provides training in processing speed, alertness, and reaction time (the standard Attention Reaction Conditioner, or ARC) (p<0.01, corrected). PSI did not significantly affect other cognitive domains such as target detection and spatial attention. Our findings suggest that PSI could improve cognitive performance, such as processing speed, during computerized cognitive training in schizophrenia. Additional studies investigating the effect of PSI during cognitive remediation are needed to further evaluate this hypothesis. Copyright © 2017. Published by Elsevier B.V.

  18. Computerized tomography of the mandibular joints and masticatory muscles

    International Nuclear Information System (INIS)

    Huels, A.B.

    1981-01-01

    A methodology for computerized tomography of the mandibular joints was developed and applied in 80 test persons. Imaging of the mandibular joints is possible with a tomographic technique with 5 mm-overlap, full utilisation of the enlargement capacity of the imaging device, and combined use of transversal and coronary tomography. The method yields full latero-medial, cranio-caudal and anterior-posterior views of the condyle and fossa contours, free of interferences and of distortions caused by the projection. Positional diagnoses are thus possible as well as diagnoses of pathological structural changes. (orig./MG) [de

  19. 2D histomorphometric quantification from 3D computerized tomography

    International Nuclear Information System (INIS)

    Lima, Inaya; Oliveira, Luis Fernando de; Lopes, Ricardo T.; Jesus, Edgar Francisco O. de; Alves, Jose Marcos

    2002-01-01

    In the present article, preliminary results are presented showing the application of the tridimensional computerized microtomographic technique (3D-μCT) to bone tissue characterization, through histomorphometric quantification which are based on stereologic concepts. Two samples of human bone were correctly prepared to be submitted to the tomographic system. The system used to realize that process were a radiographic system with a microfocus X-ray tube. Through these three processes, acquisition, reconstruction and quantification, it was possible to get the good results and coherent to the literature data. From this point, it is intended to compare these results with the information due the conventional method, that is, conventional histomorphometry. (author)

  20. The Effects of Subcrestal Implant Placement on Crestal Bone Levels and Bone-to-Abutment Contact: A Microcomputed Tomographic and Histologic Study in Dogs.

    Science.gov (United States)

    Fetner, Michael; Fetner, Alan; Koutouzis, Theofilos; Clozza, Emanuele; Tovar, Nick; Sarendranath, Alvin; Coelho, Paulo G; Neiva, Kathleen; Janal, Malvin N; Neiva, Rodrigo

    2015-01-01

    Implant design and the implant-abutment interface have been regarded as key influences on crestal bone maintenance over time. The aim of the present study was to determine crestal bone changes around implants placed at different depths in a dog model. Thirty-six two-piece dental implants with a medialized implant-abutment interface and Morse taper connection (Ankylos, Dentsply) were placed in edentulous areas bilaterally in six mongrel dogs. On each side of the mandible, three implants were placed randomly at the bone crest, 1.5 mm subcrestally, or 3.0 mm subcrestally. After 3 months, the final abutments were torqued into place. At 6 months, the animals were sacrificed and samples taken for microcomputed tomographic (micro-CT) and histologic evaluations. Micro-CT analysis revealed similar crestal or marginal bone loss among groups. Both subcrestal implant groups lost significantly less crestal and marginal bone than the equicrestal implants. Bone loss was greatest on the buccal of the implants, regardless of implant placement depth. Histologically, implants placed subcrestally were found to have bone in contact with the final abutment and on the implant platform. Implants with a centralized implant-abutment interface and Morse taper connection can be placed subcrestally without significant loss of crestal or marginal bone. Subcrestal placement of this implant system appears to be advantageous in maintaining bone height coronal to the implant platform.

  1. Celebral computerized tomography

    International Nuclear Information System (INIS)

    Lofteroed, B.; Sortland, O.

    1985-01-01

    Indications for cerebral computerized tomography (CT) and the diagnostic results from this examination are evaluated in 127 children. Pathological changes were found in 31 children, mostly based on such indications as increasing head size, suspicion of brain tumor, cerebral paresis, delayed psychomotor development and epileptic seizures. A list of indications for CT in children is given

  2. Evaluation of symphysis pubis and sacroiliac joint distances in skeletally immature patients: A computerized tomography study of 1020 individuals.

    Science.gov (United States)

    Kalenderer, Önder; Turgut, Ali; Bacaksız, Tayfun; Bilgin, Emre; Kumbaracı, Mert; Akkan, Hasan Ali

    2017-03-01

    The aim of this study was to create a reference about normal pubic symphysis and sacroiliac joint widths of children and adolescents. A total of 1020 computerized tomography axial scans of patients without pelvic injury between 2 and 18 year-old were studied. The narrowest width of pubic symphysis and bilateral sacroiliac joints were measured. The average pubic symphyseal width at 2 years old boys was 6.35 ± 1.06 mm (4.88-9.13 mm). The average of right and left sacroiliac joints' widths at 2 years old boys was 4.56 ± 0.65 mm (3.59-6.07 mm) and 4.58 ± 0.66 mm (3.44-5.74 mm), respectively. The average pubic symphyseal width of 2 years old girls was 5.85 ± 1.14 mm (4.06-8.20 mm). The average of right and left sacroiliac joints' widths at 2 years old girls was found 4.36 ± 0.56 mm (3.50-5.37 mm) and 4.42 ± 0.59 mm (3.58-5.73 mm), respectively. The average pubic symphyseal width at 18 years old boys was found 3.68 ± 1.30 mm (1.90-5.79 mm). The average of right and left sacroiliac joints' widths at 18 years old boys was found 1.97 ± 0.21 mm (1.73-2.41 mm) and 2.04 ± 0.30 mm (1.70-2.65 mm), respectively. The average pubic symphyseal width at 18 years old girls was 3.92 ± 0.52 mm (2.97-4.76 mm). The average of right and left sacroiliac joints' widths at 18 years old girls was found 2.34 ± 0.40 mm (1.58-3.34 mm) and 2.33 ± 0.37 mm (1.58-3.10 mm), respectively. Our results suggest that one should be suspicious about pelvic injury if the width of pubic symphysis is over 10 mm and width of sacroiliac joint is over 8 mm especially in patients younger than 10 years-old. Level III Diagnostic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  3. The effects of an 8-week computerized cognitive training program in older adults: a study protocol for a randomized controlled trial.

    Science.gov (United States)

    Ten Brinke, Lisanne F; Best, John R; Crockett, Rachel A; Liu-Ambrose, Teresa

    2018-01-30

    Given the world's aging population, it is important to identify strategies that promote healthy cognitive aging and minimize cognitive decline. Currently, no curative pharmaceutical therapy exists for cognitive impairment and dementia. As a result, there is much interest in lifestyle approaches. Specifically, complex mental activity, such as cognitive training, may be a promising method to combat cognitive decline in older adults. As such, the industry of commercial computerized cognitive training (CCT) applications has rapidly grown in the last decade. However, the efficacy of these commercial products is largely not established. Moreover, exercise is a recognized strategy for promoting cognitive outcomes in older adults and may augment the efficacy of computerized cognitive training applications. Therefore, we propose a proof-of-concept randomized controlled trial (RCT) to examine the effect of a commercial CCT program in community-dwelling older adults. An 8-week RCT to examine the effect of a commercial CCT program, alone and preceded by a 15-min brisk walk, on cognitive function and explore the underlying neural mechanisms in adults aged 65-85 years old. Participants will be randomized to one of three intervention groups: 1) Computerized cognitive training (FBT); 2) A 15-min brisk walk followed by computerized cognitive training (Ex-FBT); or 3) A combination of educational classes, sham cognitive training, and balanced and tone exercises (active control, BAT). Participants in all intervention groups will attend three one-hour classes per week over the course of the intervention. Participants will be assessed at baseline, trial completion, and 1-year post study completion (1-year follow-up). If results from this study show benefits for cognition at trial completion, CCT programs, alone or in combination with walking, might be a strategy to promote healthy cognitive aging in older adults. In addition, results from the 1-year follow-up measurement could provide

  4. Computer tomographic diagnosis of echinococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Haertel, M.; Fretz, C.; Fuchs, W.A.

    1980-08-01

    The computer tomographic appearances and differential diagnosis in 22 patients with echinococcosis are described; of these, twelve were of the cystic and ten of the alveolar type. The computer tomographic appearances are characterised by the presence of daughter cysts (66%) within the sharply demarkated parasitic cyst of water density. In the absence of daughter cysts, a definite aetiological diagnosis cannot be made, although there is a tendency to clasification of the occassionally multiple echinococcus cysts. The computer tomographic appearances of advanced alveolar echinococcosis are characterised by partial collequative necrosis, with clacification around the necrotic areas (90%). The absence of CT evidence of partial necrosis and calsification of the pseudotumour makes it difficult to establish a specific diagnosis. The conclusive and non-invasive character of the procedure and its reproducibility makes computer tomography the method of choice for the diagnosis and follow-up of echinococcosis.

  5. Feasibility of photon-counting K-edge imaging in X-ray and computed tomographic systems: Monte Carlo simulation studies

    International Nuclear Information System (INIS)

    Lee, Seung-Wan; Choi, Yu-Na; Cho, Hyo-Min; Lee, Young-Jin; Ryu, Hyun-Ju; Kim, Hee-Joung

    2011-01-01

    Conventional X-ray systems and X-ray computed tomography (CT) systems, which use detectors operated in the integrating mode, are not able to reflect spectral information because the detector output is proportional to the energy fluence integrated over the whole spectrum. Photon-counting detectors have been considered as alternative devices. These detectors can measure the photon energy deposited by each event and improve the image quality. In this study, we investigated the feasibility of K-edge imaging using a photon-counting detector and evaluated the capability of material decomposition in X-ray images. The geometries of X-ray imaging systems equipped with cadmium telluride (CdTe) detectors and phantoms consisting of different materials were designed using Geant4 Application for Tomographic Emission (GATE) version 6.0. To observe the effect of a discontinuity in the attenuation due to the K-edge of a high atomic number material, we chose the energy windows to be one below and one above the K-edge absorption energy of the target material. The contrast-to-noise ratios (CNRs) of the target materials were increased at selective energy levels above the K-edge absorption energy because the attenuation is more dramatically increased at energies above the K-edge absorption energy of the material than at energies below that. The CNRs for the target materials in the K-edge image were proportional to the material concentration. The results of this study show that K-edge imaging can be carried out in conventional X-ray systems and X-ray CT systems using CdTe photon-counting detectors and that the target materials can be separated from background materials by using K-edge imaging. The photon-counting detector has potential to provide improved image quality, and this study will be used as a basis for future studies on photon-counting X-ray imaging.

  6. Computerized Working-Memory Training for Children Following Arterial Ischemic Stroke: A Pilot Study With Long-Term Follow-Up.

    Science.gov (United States)

    Eve, Megan; O'Keeffe, Fiadhnait; Jhuty, Simren; Ganesan, Vijeya; Brown, Gary; Murphy, Tara

    2016-01-01

    Cognitive deficits in the domains of working memory (WM) and executive function are well documented following childhood arterial ischemic stroke (AIS). However, there are currently no evidence-based cognitive interventions for this population. Computerized, implicit WM training has been demonstrated to generate generalized cognitive gains for children with WM and attention deficits and for adults following brain injury. This study used a pilot design to investigate the efficacy and feasibility of such an intervention program (Cogmed WM Training) for a childhood AIS population. Outcomes were measured via psychometric assessment at preintervention and postintervention and again at 1-year follow-up. At longitudinal follow-up, participants were found to have significant and persistent cognitive difficulties, particularly with attention and response inhibition. Following the computerized, implicit WM intervention, a significant improvement in phonological-loop WM was seen; however, this improvement was not maintained after 12 months. No additional significant improvements on standardized psychometric outcome measures were seen either immediately or at 12-month follow-up. Findings of this pilot study therefore do not currently support Cogmed as an effective intervention for children with AIS but highlight the need for further research, including randomized, controlled trials, to investigate cognitive interventions for the childhood AIS population.

  7. Computerized tomography of adrenal glands in the investigation of Cushing's syn

    International Nuclear Information System (INIS)

    Abucham Filho, J.; Albertotti, C.; Kater, C.E.; Vieira, J.G.H.; Chacra, A.R.

    1983-01-01

    Computerized tomography of the adrenal glands was performed in 10 patients with Cushing's syndrome using a G.E. 8800 CT/T Body Scanner. The tomographic findings of unilateral adrenal masses in 4 patients were confirmed by surgery. In the remaining 6 patients, computerized tomography did not identify any masses, and both glands were well visualized and showed normal shape. In these patients, measurement of the adrenal glands revealed both normal (n=1) and enlarged glands (n=5). The findings of adrenalectomy (n=4) or transphenoidal surgery and follow-up (n=2) established the diagnosis of adrenal phyperplasia in all patients. (Author) [pt

  8. Accessing leaking underground storage tank case studies and publications through the EPA's Computerized On-Line Information System (COLIS)

    International Nuclear Information System (INIS)

    Hillger, R.; Tibay, P.

    1991-01-01

    The US EPA's regulations for underground storage tanks (USTs) require corrective action to be taken in response to leaking USTs. Recent developments of UST programs nationwide as well as the introduction of new technologies to clean up UST sites have increased the diversity of experience levels among personnel involved with this type of work. The EPA's Computerized On-Line Information System (COLIS) has been developed to facilitate technology transfer among the personnel involved in UST cleanup. The system allows for the quick and simple retrieval of data relating to UST incidents, as well as other hazardous waste-related information. The system has been used by response personnel at all levels of government, academia, and private industry. Although it has been in existence for many years, users are just now realizing the potential wealth of information stored in this system. COLIS access can be accomplished via telephone lines utilizing a personal computer and a modem

  9. Computerized Assessment of Competence-Related Abilities in Living Liver Donors: The Adult-to-Adult Living Donor Liver Transplantation Cohort Study (A2ALL)

    Science.gov (United States)

    Freeman, Jason; Emond, Jean; Gillespie, Brenda W.; Appelbaum, Paul S.; Weinrieb, Robert; Hill-Callahan, Peg; Gordon, Elisa J.; Terrault, Norah; Trotter, James; Ashworth, April; Dew, Mary Amanda; Pruett, Timothy

    2014-01-01

    Background Despite its importance, determination of competence to consent to organ donation varies widely based on local standards. We piloted a new tool to aid transplant centers in donor assessment. Methods We assessed competence-related abilities among potential living liver donors (LDs) in the 9-center A2ALL study. Prospective LDs viewed an educational video, and were queried to assess Understanding, Appreciation, Reasoning, and ability to express a Final Choice using the MacArthur Competence Assessment Tool for Clinical Research, adapted for computerized administration in LDs (“MacLiver”). Videotaped responses were scored by a clinical neuropsychologist (JF). Results Ninety-three LDs were assessed. Mean (standard deviation; domain maximum) scores were: Understanding: 18.1 (2.6; max=22), Appreciation: 5.1 (1.0; max=6), Reasoning: 3.1 (0.8; max=4), and Final Choice: 3.8 (0.5; max=4). Scores did not differ by demographics, relationship to the recipient, eligibility to donate, or eventual donation (p>0.4). Higher education was associated with greater Understanding (p=0.004) and Reasoning (p=0.03). Conclusion Standardized, computerized education with independent ratings of responses may (1) alert the clinical staff to potential donors who may not be competent to donate, and (2) highlight areas needing further assessment and education, leading to better informed decision-making. PMID:23859354

  10. A new computerized cognitive and social cognition training specifically designed for patients with schizophrenia/schizoaffective disorder in early stages of illness: A pilot study.

    Science.gov (United States)

    Fernandez-Gonzalo, Sol; Turon, Marc; Jodar, Merce; Pousa, Esther; Hernandez Rambla, Carla; García, Rebeca; Palao, Diego

    2015-08-30

    People with schizophrenia/schizoaffective disorders at early stages of the illness present cognitive and social cognition deficits that have a great impact in functional outcomes. Cognitive Remediation Therapy (CRT) has demonstrated consistent effect in cognitive performance, symptoms and psychosocial functioning. However, any CRT intervention or social cognition training have been specifically designed for patients in the early stages of psychosis. The aim of this pilot study is to assess the efficacy of a new computerized cognitive and social cognition program for patients with schizophrenia/schizoaffective disorder with recent diagnosis. A comprehensive assessment of clinical, social and non-social cognitive and functional measures was carried out in 53 randomized participants before and after the 4-months treatment. Significant results were observed in Spatial Span Forwards, Immediate Logical Memory and Pictures of Facial Affect (POFA) total score. None of these results were explained by medication, premorbid social functioning or psychopathological symptoms. No impact of the intervention was observed in other cognitive and social cognition outcome neither in clinical and functional outcomes. This new computerized intervention may result effective ameliorating visual attention, logical memory and emotional processing in patients in the early stages of schizophrenia/schizoaffective disorder. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. A study of root canal morphology of human primary incisors and molars using cone beam computerized tomography: an in vitro study.

    Science.gov (United States)

    Gaurav, Vivek; Srivastava, Nikhil; Rana, Vivek; Adlakha, Vivek Kumar

    2013-01-01

    Variations in morphology of root canals in primary teeth usually leads to complications during and after endodontic therapy. To improve the success in endodontics, a thorough knowledge of the root canal morphology is essential. The aim of this study was to assess the variation in number and morphology of the root canals of primary incisors and molars and to study the applicability of cone beam computerized tomography (CBCT) in assessing the same. A total of 60 primary molars and incisors with full root length were collected and various parameters such as the number of roots, number of canals, diameter of root canal at cementoenamel junction and middle-third, length and angulations of roots of primary molars and incisors were studied using CBCT. The observations were put to descriptive statistics to find out the frequency, mean, standard deviation and range for all four subgroups. Further, unpaired t-test was used to compare these parameters between subgroups and analysis of variance test was implemented to evaluate the parameters within the subgroups. The CBCT showed the presence of bifurcation of root canal at middle third in 13% of mandibular incisors while 20% of mandibular molars had two canals in distal root. The diameter of distobuccal root canal of maxillary molars and mesiolingual canal of mandibular molars was found to be minimum. CBCT is a relatively new and effective technology, which provides an auxiliary imaging modality to supplement conventional radiography for assessing the variation in root canal morphology of primary teeth.

  12. Evaluation of brain scintigraphy and computerized tomography

    International Nuclear Information System (INIS)

    Cavailloles, F.; Dairou, R.; Desbleds, M.T.; Benoit, C.; Larmande, P.; Bok, B.; Alperovitch, A.

    1983-01-01

    In order to assess the clinical usefulness of brain computerized tomography and radionuclide scan, a prospective study was performed on a series of 554 patients. The detection rate was assessed as well as the identification rate of lesions. In addition, the usefulness of both tests was appreciated subjectively by two neurologists reviewing the patients' files. Both give reasonably similar results: computerized tomography is superior to radionuclide scan in the diagnosis of tumors and intracerebral hematomas, the radionuclide scan being slightly superior in the diagnosis of purely ischemic CVA and subdural hematomas. The superiority which was subjectively conceded to computerized tomography was greater than that objectively demonstrated. However, clinical usefulness of computerized tomography was judged important in only 50% of the cases. Moreover, to request both computerized tomography and radionuclide scan appeared as having no interest in 83% of the cases. In that series, the diagnostic hypotheses were in agreement with the final diagnosis in 88% of the cases. Bias encountered in this type of studies are discussed [fr

  13. Computerized plant maintenance management

    International Nuclear Information System (INIS)

    Kozusko, A.M.

    1986-01-01

    The evolution of the computer has and continues to have a great impact on industry. We are in an adjustment cycle with the current computer evolution, and will need to adapt to make the changes for the coming decade. Hardware and software are continually being enhanced. Computers are becoming more powerful and will eventually provide an effective man-machine interface. This paper shares experiences encountered during implementations of computerized maintenance systems

  14. Tomographic methods in nuclear medicine

    International Nuclear Information System (INIS)

    Ahluwalia, B.D.

    1989-01-01

    This book is a review of the various approaches to tomographic imaging that have been pursued in nuclear medicine. The evolution of single photon emission computed tomography (SPECT) is discussed in detail, and the major classes of instrumentation are represented. A section on positron emission tomography is also included, but is rather brief and may serve only as a general introduction

  15. Original circuitry for TOHR tomograph

    International Nuclear Information System (INIS)

    Cuzon, J.C.; Pinot, L.

    1999-01-01

    Having industrialization in mind, a specific electronics for a high resolution tomograph is designed out of the usual standards of nuclear physics. All the information are converted in the time domain and a fast processor, in front of the data acquisition, carries out the time and energy coincidences. (authors)

  16. Effect of Post Space Preparation on Apical Obturation Quality of Teeth Obturated with Different Techniques: A Micro-computed Tomographic Study.

    Science.gov (United States)

    Küçükkaya Eren, Selen; Askerbeyli Örs, Sevinc; Yılmaz, Zeliha

    2017-07-01

    The purpose of this study was to evaluate the obturation quality of root canals filled with different techniques and to determine whether post space preparation had an effect on the quality of apical obturation using micro-computed tomographic (micro-CT) imaging. The root canals of 30 human mandibular premolar teeth were instrumented, and the specimens were divided into 3 groups according to the obturation technique used: cold lateral compaction (CLC), warm vertical compaction (WVC), or single-cone (SC) techniques. The specimens were stored at 37°C and 100% humidity for 1 week. Then, the coronal root filling material was removed in order to create a post space. Micro-CT scans were performed before and after post space preparation for the volumetric analysis of voids and filling materials. Data were analyzed using repeated-measures analysis of variance and Bonferroni tests. The CLC and SC groups showed a significantly greater percentage volume of voids than the WVC group (P space preparation (P > .05). The post space preparation caused a significant increase in the percentage volume of voids in the CLC and SC groups (P space preparation (P > .05). No root fillings were void free. The WVC group presented the best obturation quality. The post space preparation negatively influenced the apical integrity of the filling materials in the CLC and SC groups, whereas it had no significant effect in the WVC group. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Evaluation of quality of tomographs of Rio de Janeiro state, Brazil; Avaliacao da qualidade dos tomografos do estado do Rio de Janeiro

    Energy Technology Data Exchange (ETDEWEB)

    Travassos, P.C.B.; Belem, V.R.; Magalhaes, L.A.; Almeida, C.E.A. de, E-mail: luisalexandregm@hotmail.com [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas

    2014-07-01

    Computerized tomographs used in 56 institutions in the state of Rio de Janeiro were evaluated. Criteria of image quality and dosimetry were submitted. The results showed that some not performed optimize their protocols examinations or perform wrongly, which results in an increase in the dose received by patients, and an image in compromised quality. (author)

  18. The baboon model under anaesthesia for in vivo cerebral blood flow studies using single photon emission computed tomographic (SPECT) techniques

    International Nuclear Information System (INIS)

    Dormehl, I.; Redelinghuys, F.; Hugo, N.; Oliver, D.; Pilloy, W.

    1992-01-01

    Single photon computed tomography of the brain can be useful in animal experimentation directed towards cerebral conditions. A well established and understood baboon model, necessarily under anaesthesia, could especially be valuable in such investigations. Six normal baboons were studied under various anesthetic agents and their combinations: ketamine, thiopentone, pentobarbitone and halothane. Cerebral blood flow (CBF) studies were performed with 99m Tc-HMPAO. CBF effects from various anaesthesia were detected, requiring careful choice of the anaesthesia for cerebral investigations. (author). 13 refs, 4 figs, 3 tabs

  19. The baboon model under anaesthesia for in vivo cerebral blood flow studies using single photon emission computed tomographic (SPECT) techniques

    Energy Technology Data Exchange (ETDEWEB)

    Dormehl, I.; Redelinghuys, F.; Hugo, N. [Pretoria Univ. (South Africa); Oliver, D.; Pilloy, W. [Medical Univ. of Southern Africa (MEDUNSA), Pretoria (South Africa)

    1992-12-31

    Single photon computed tomography of the brain can be useful in animal experimentation directed towards cerebral conditions. A well established and understood baboon model, necessarily under anaesthesia, could especially be valuable in such investigations. Six normal baboons were studied under various anesthetic agents and their combinations: ketamine, thiopentone, pentobarbitone and halothane. Cerebral blood flow (CBF) studies were performed with {sup 99m}Tc-HMPAO. CBF effects from various anaesthesia were detected, requiring careful choice of the anaesthesia for cerebral investigations. (author). 13 refs, 4 figs, 3 tabs.

  20. Single photon emission computerized tomography

    International Nuclear Information System (INIS)

    Hooge, P. de.

    1983-01-01

    In this thesis two single-photon emission tomographic techniques are presented: (a) longitudinal tomography with a rotating slanting-hole collimator, and (b) transversal tomography with a rotating gamma camera. These methods overcome the disadvantages of conventional scintigraphy. Both detection systems and the image construction methods are explained and comparisons with conventional scintigraphy are drawn. One chapter is dedicated to the determination of system parameters like spatial resolution, contrast, detector uniformity, and size of the object, by phantom studies. In separate chapters the results are presented of detection of tumors and metastases in the liver and the liver hilus; skeletal diseases; various pathological aberrations of the brain; and myocardial perfusion. The possible use of these two ect's for other organs and body areas is discussed in the last chapter. (Auth.)

  1. Cognitive performance in relapsing remitting multiple sclerosis: A longitudinal study in daily practice using a brief computerized cognitive battery

    Directory of Open Access Journals (Sweden)

    Jacquerye Philippe

    2011-06-01

    Full Text Available Abstract Background There is need for a cognitive test battery that can be easily used in clinical practice to detect or monitor cognitive performance in patients with multiple sclerosis (MS. In order to conduct, in this patient group, a preliminary investigation of the validity and utility of a brief computerized battery, the Cognitive Drug Research (CDR battery, we longitudinally assessed cognition in patients with relapsing remitting (RR MS. Methods Forty-three mildly disabled, clinically active RRMS patients were repeatedly assessed with the Digit Symbol Substitution Test (DSST, Paced Auditory Serial Addition Test (PASAT and five composite scores derived from the CDR computerized cognitive test system (CDR System: Power of Attention, Continuity of Attention, Quality of Working Memory, Quality of Episodic Memory and Speed of Memory. The Multiple Sclerosis Functional Composite (MSFC and Expanded Disability Status Scale (EDSS measured disability. Results The composite scores from the CDR battery generally showed excellent test-retest reliability over the repeated assessments, though was low on occasions for the Quality of Working Memory and Quality of Episodic Memory measures. The CDR measures tended to be highly correlated with other measures of cognition (DSST and PASAT and were also strongly related to disability (EDSS and MSFC. Baseline scores indicated large impairments to visual information processing speed and attention (DSST, Cohen's d 1.1; Power of Attention d 1.4 [reaction time on tasks of focussed and sustained attention], and a moderate impairment both to sustained attention (Continuity of Attention d 0.6 and complex information processing speed (Speed of memory d 0.7 [reaction time on tasks of working and episodic Memory], when compared to normative data derived from healthy volunteers enrolled in a series of separate, prior clinical trials. Working memory (Quality of Working Memory and episodic memory (Quality of Episodic Memory

  2. PATHOMORPHOLOGICAL AND COMPUTERIZED TOMOGRAPHY STUDY OF IBUPROFEN AND COMBINATION WITH 2-PHENYL-3-CARBETHOXY-4-DIMETHYLAMINOMETHYL-5-OKSIBENZOFURAN HYDROCHLORIDE (VINBORON INFLUENCE ON THE JOINTS OF LOWER EXTREMITIES OF RATS WITH EXPERIMENTAL RHEUMATOID ARTHRITIS

    Directory of Open Access Journals (Sweden)

    F. V. Hladkykh

    2017-01-01

    -ray tomographic scanner “Point 3D Combi 500” (PointNix, South Korea, using a planar sensor with a scanning site of 9 × 12 mm and a radial load of 30-100 μSv. Scanning was carried out with a voltage of 52.0 kV and the electric current of 6.0 mA. For the integral characteristics of the linear dimensions of rats’ hind limbs joints we proposed a formula for calculating the joint volume (Patent of Ukraine No. UA 117538. For the integral characteristics of the dimensions of rats’ hind limbs linear joints we proposed a formula for calculating the joint volume (Patent of Ukraine No. UA 117538.Results and discussion. The use of ibuprofen in combination with vinboron was accompanied by restoration of the structure and function of the cartilage and bone tissues, evidenced by the appearance of acidic and sulfated glycosaminoglycans. The restoration of the bone tissue was realized by the proliferation of the connective tissue and its transformation into cartilage. The synovial membrane was hyperplastic with proliferating synoviocytes of both macrophage and secretory types. In rare cases, the phenomenon of moderate edema and minor focal lymphohistiocytic infiltration persisted. Thus, the use of ibuprofen and ibuprofen in combination with vinboron in rats with adjuvant arthritis resulted in a reduction or absence of inflammation in both the joint and periarticular tissues. The analysis of the results of cone-ray computerized tomography and digital radiography showed that against the background of simultaneous administration of ibuprofen and vinboron there was a tendency to increase the anti-inflammatory effect of the studied antiphlogistics on the rats’ joints affected by adjuvant arthritis. On the 28-th day of the experiment there was the indicatation of decrease of the volume of the hind limb joints by an average of 33.8% compared to the control animals and a near-complete restoration of the width of the joint gaps of the joints examined. It was also determined that vinboron can

  3. Hand and nickel-titanium root canal instrumentation performed by dental students: a micro-computed tomographic study.

    Science.gov (United States)

    Peru, M; Peru, C; Mannocci, F; Sherriff, M; Buchanan, L S; Pitt Ford, T R

    2006-02-01

    The aim of this study was to evaluate root canals instrumented by dental students using the modified double-flared technique, nickel-titanium (NiTi) rotary System GT files and NiTi rotary ProTaper files by micro-computed tomography (MCT). A total of 36 root canals from 18 mesial roots of mandibular molar teeth were prepared; 12 canals were prepared with the modified double-flared technique, using K-flexofiles and Gates-Glidden burs; 12 canals were prepared using System GT and 12 using ProTaper rotary files. Each root was scanned using MCT preoperatively and postoperatively. At the coronal and mid-root sections, System GT and ProTaper files produced significantly less enlarged canal cross-sectional area, volume and perimeter than the modified double-flared technique (P ProTaper (P ProTaper and System GT were able to prepare root canals with little or no procedural error compared with the modified double-flared technique. Under the conditions of this study, inexperienced dental students were able to prepare curved root canals with rotary files with greater preservation of tooth structure, low risk of procedural errors and much quicker than with hand instruments.

  4. Conceptual design of the tomographic system for simultaneous studying of soft and hard X-ray emission from dense magnetized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Bielecki, J., E-mail: jakub.bielecki@ifj.edu.edu; Wójcik-Gargula, A.; Scholz, M.

    2016-11-15

    The article presents a new approach for investigation of spatial distributions of soft and hard X-rays emitted from dense magnetized plasma. The approach is based on the application of tomographic methods to the X-ray emission reconstruction in a plasma focus (PF) device. Quantitative investigation of the anisotropy of the reconstructed X–ray plasma emissivity may help to explain the nature of fusion reaction mechanisms in a PF device. The aim of this work is to present a conceptual design of a novel dual-energy X-ray emission tomographic system dedicated to the PF-24 plasma focus device. The system, which enables the simultaneous registration of soft and hard X-rays, is composed of three X‐ray pinhole cameras. Each camera is equipped with a pair of 16-element Si photodiode arrays arranged in two layers separated by an aluminum attenuator. The Geant4 code was used to optimize the layout and parameters of the applied detectors. In addition, a method of tomographic reconstruction from a sparse data set provided by the experimental setup has been presented.

  5. Atom-probe tomographic study of interfaces of Cu{sub 2}ZnSnS{sub 4} photovoltaic cells

    Energy Technology Data Exchange (ETDEWEB)

    Tajima, S., E-mail: e0954@mosk.tytlabs.co.jp; Asahi, R.; Itoh, T.; Hasegawa, M.; Ohishi, K. [Toyota Central R and D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan); Isheim, D.; Seidman, D. N. [Northwestern University, Evanston, Illinois 60208-3108 (United States)

    2014-09-01

    The heterophase interfaces between the CdS buffer layer and the Cu{sub 2}ZnSnS{sub 4} (CZTS) absorption layers are one of the main factors affecting photovoltaic performance of CZTS cells. We have studied the compositional distributions at heterophase interfaces in CZTS cells using three-dimensional atom-probe tomography. The results demonstrate: (a) diffusion of Cd into the CZTS layer; (b) segregation of Zn at the CdS/CZTS interface; and (c) a change of oxygen and hydrogen concentrations in the CdS layer depending on the heat treatment. Annealing at 573 K after deposition of CdS improves the photovoltaic properties of CZTS cells probably because of the formation of a heterophase epitaxial junction at the CdS/CZTS interface. Conversely, segregation of Zn at the CdS/CZTS interface after annealing at a higher temperature deteriorates the photovoltaic properties.

  6. Phantom and Clinical Study of Differences in Cone Beam Computed Tomographic Registration When Aligned to Maximum and Average Intensity Projection

    Energy Technology Data Exchange (ETDEWEB)

    Shirai, Kiyonori [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Nishiyama, Kinji, E-mail: sirai-ki@mc.pref.osaka.jp [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Katsuda, Toshizo [Department of Radiology, National Cerebral and Cardiovascular Center, Osaka (Japan); Teshima, Teruki; Ueda, Yoshihiro; Miyazaki, Masayoshi; Tsujii, Katsutomo [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan)

    2014-01-01

    Purpose: To determine whether maximum or average intensity projection (MIP or AIP, respectively) reconstructed from 4-dimensional computed tomography (4DCT) is preferred for alignment to cone beam CT (CBCT) images in lung stereotactic body radiation therapy. Methods and Materials: Stationary CT and 4DCT images were acquired with a target phantom at the center of motion and moving along the superior–inferior (SI) direction, respectively. Motion profiles were asymmetrical waveforms with amplitudes of 10, 15, and 20 mm and a 4-second cycle. Stationary CBCT and dynamic CBCT images were acquired in the same manner as stationary CT and 4DCT images. Stationary CBCT was aligned to stationary CT, and the couch position was used as the baseline. Dynamic CBCT was aligned to the MIP and AIP of corresponding amplitudes. Registration error was defined as the SI deviation of the couch position from the baseline. In 16 patients with isolated lung lesions, free-breathing CBCT (FBCBCT) was registered to AIP and MIP (64 sessions in total), and the difference in couch shifts was calculated. Results: In the phantom study, registration errors were within 0.1 mm for AIP and 1.5 to 1.8 mm toward the inferior direction for MIP. In the patient study, the difference in the couch shifts (mean, range) was insignificant in the right-left (0.0 mm, ≤1.0 mm) and anterior–posterior (0.0 mm, ≤2.1 mm) directions. In the SI direction, however, the couch position significantly shifted in the inferior direction after MIP registration compared with after AIP registration (mean, −0.6 mm; ranging 1.7 mm to the superior side and 3.5 mm to the inferior side, P=.02). Conclusions: AIP is recommended as the reference image for registration to FBCBCT when target alignment is performed in the presence of asymmetrical respiratory motion, whereas MIP causes systematic target positioning error.

  7. Phantom and Clinical Study of Differences in Cone Beam Computed Tomographic Registration When Aligned to Maximum and Average Intensity Projection

    International Nuclear Information System (INIS)

    Shirai, Kiyonori; Nishiyama, Kinji; Katsuda, Toshizo; Teshima, Teruki; Ueda, Yoshihiro; Miyazaki, Masayoshi; Tsujii, Katsutomo

    2014-01-01

    Purpose: To determine whether maximum or average intensity projection (MIP or AIP, respectively) reconstructed from 4-dimensional computed tomography (4DCT) is preferred for alignment to cone beam CT (CBCT) images in lung stereotactic body radiation therapy. Methods and Materials: Stationary CT and 4DCT images were acquired with a target phantom at the center of motion and moving along the superior–inferior (SI) direction, respectively. Motion profiles were asymmetrical waveforms with amplitudes of 10, 15, and 20 mm and a 4-second cycle. Stationary CBCT and dynamic CBCT images were acquired in the same manner as stationary CT and 4DCT images. Stationary CBCT was aligned to stationary CT, and the couch position was used as the baseline. Dynamic CBCT was aligned to the MIP and AIP of corresponding amplitudes. Registration error was defined as the SI deviation of the couch position from the baseline. In 16 patients with isolated lung lesions, free-breathing CBCT (FBCBCT) was registered to AIP and MIP (64 sessions in total), and the difference in couch shifts was calculated. Results: In the phantom study, registration errors were within 0.1 mm for AIP and 1.5 to 1.8 mm toward the inferior direction for MIP. In the patient study, the difference in the couch shifts (mean, range) was insignificant in the right-left (0.0 mm, ≤1.0 mm) and anterior–posterior (0.0 mm, ≤2.1 mm) directions. In the SI direction, however, the couch position significantly shifted in the inferior direction after MIP registration compared with after AIP registration (mean, −0.6 mm; ranging 1.7 mm to the superior side and 3.5 mm to the inferior side, P=.02). Conclusions: AIP is recommended as the reference image for registration to FBCBCT when target alignment is performed in the presence of asymmetrical respiratory motion, whereas MIP causes systematic target positioning error

  8. Analysis of concrete material through gamma ray computerized tomography

    International Nuclear Information System (INIS)

    Oliveira Junior, J.M. de

    2004-01-01

    Computerized Tomography (CT) refers to the cross sectional imaging of an object from both transmission or reflection data collected by illuminating the object from many different directions. The most important contribution of CT is to greatly improve abilities to distinguish regions with different gamma ray transmittance and to separate over-lying structures. The mathematical problem of the CT imaging is that of estimating an image from its projections. These projections can represent, for example, the linear attenuation coefficient of γ-rays along the path of the ray. In this work we will present some new results obtained by using tomographic techniques to analyze column samples of concrete to check the distribution of various materials and structural problems. These concrete samples were made using different proportions of stone, sand and cement. Another set of samples with different proportions of sand and cement were also used to verify the outcome from the CT analysis and the differences between them. Those samples were prepared at the Material Laboratory of Faculdade de Engenharia de Sorocaba, following the same procedures used in real case of concrete tests. The projections used in this work was obtained by Mini Computerized Tomograph of Uniso (MTCU), located at the Experimental Nuclear Physics Laboratory at University of Sorocaba. This tomograph operates with a gamma ray source of 241 Am (photons of 60 keV and 100 mCi of intensity) and a NaI(Tl) solid state detector. The system features translation and rotation scanning modes, a 100 mm effective field of view, and 1 mm spatial resolution. The image reconstruction problem is solved using Discrete Filtered Backprojection (FBP). (author)

  9. 'Too much, too late': mixed methods multi-channel video recording study of computerized decision support systems and GP prescribing.

    Science.gov (United States)

    Hayward, James; Thomson, Fionagh; Milne, Heather; Buckingham, Susan; Sheikh, Aziz; Fernando, Bernard; Cresswell, Kathrin; Williams, Robin; Pinnock, Hilary

    2013-06-01

    Computerized decision support systems (CDSS) are commonly deployed to support prescribing, although over-riding of alerts by prescribers remains a concern. We aimed to understand how general practitioners (GPs) interact with prescribing CDSS in order to inform deliberation on how better to support prescribing decisions in primary care. Quantitative and qualitative analysis of interactions between GPs, patients, and computer systems using multi-channel video recordings of 112 primary care consultations with eight GPs in three UK practices. 132 prescriptions were issued in the course of 73 of the consultations, of which 81 (61%) attracted at least one alert. Of the total of 117 alerts, only three resulted in the GP checking, but not altering, the prescription. CDSS provided information and safety alerts at the point of generating a prescription. This was 'too much, too late' as the majority of the 'work' of prescribing occurred prior to using the computer. By the time an alert appeared, the GP had formulated the problem(s), potentially spent several minutes considering, explaining, negotiating, and reaching agreement with the patient about the proposed treatment, and had possibly given instructions and printed an information leaflet. CDSS alerts do not coincide with the prescribing workflow throughout the whole GP consultation. Current systems interrupt to correct decisions that have already been taken, rather than assisting formulation of the management plan. CDSS are likely to be more acceptable and effective if the prescribing support is provided much earlier in the process of generating a prescription.

  10. Implementation of a Computerized Tablet-Survey in an Adolescent Large-Scale, School-Based Study.

    Science.gov (United States)

    Delk, Joanne; Harrell, Melissa B; Fakhouri, Tala H I; Muir, Katelyn A; Perry, Cheryl L

    2017-07-01

    Computerized surveys present many advantages over paper surveys. However, school-based adolescent research questionnaires still mainly rely on paper-and-pencil surveys as access to computers in schools is often not practical. Tablet-assisted self-interviews (TASI) present a possible solution, but their use is largely untested. This paper presents a method for and our experiences with implementing a TASI in a school setting. A TASI was administered to 3907 middle and high school students from 79 schools. The survey assessed use of tobacco products and exposure to tobacco marketing. To assess in-depth tobacco use behaviors, the TASI employed extensive skip patterns to reduce the number of not-applicable questions that nontobacco users received. Pictures were added to help respondents identify the tobacco products they were being queried about. Students were receptive to the tablets and required no instructions in their use. None were lost, stolen, or broken. Item nonresponse, unanswered questions, was a pre-administration concern; however, 92% of participants answered 96% or more of the questions. This method was feasible and successful among a diverse population of students and schools. It generated a unique dataset of in-depth tobacco use behaviors that would not have been possible through a paper-and-pencil survey. © 2017, American School Health Association.

  11. Contrast-enhanced computed tomographic colonography in the follow-up of colorectal cancer patients: a feasibility study

    International Nuclear Information System (INIS)

    Laghi, Andrea; Iannaccone, Riccardo; Carbone, Iacopo; Piacentini, Francesca; Passariello, Roberto; Bria, Emilio; Trasatti, Luciana; Lauro, Salvatore; Vecchione, Aldo

    2003-01-01

    The aim of our study was to assess whether contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up program of colorectal cancer patients. Thirty-five patients, surgically treated for colorectal cancer, underwent a follow-up program that included physical examination, carcinoembryonic antigen serum assay, conventional colonoscopy, liver ultrasonography, and chest X-ray. For these patients, we added a yearly contrast-enhanced CT colonography. All CT examinations were performed with a high-resolution protocol using a multidetector spiral CT scanner (Siemens, Erlangen, Germany) prior to and after the administration of 130 ml of i.v. contrast material. Images were directly analyzed on a dedicated workstation by two radiologists to determine colonic evaluation, visualization of colonic anastomosis, presence of polyps, and extra-colonic findings. Colonic evaluation was judged as optimal in 91.7% of all colonic segments. All mechanical surgical anastomoses were visualized with CT colonography. There was no evidence of anastomotic recurrence. Seven polyps were detected in five different patients with CT colonography, with two false-positive and no false-negative examinations. Three liver metastases and two basal pulmonary nodules were also identified. Contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up of patients operated on for colorectal cancer. (orig.)

  12. Computed tomographic diagnosis for hepatofugal collaterals in portal hypertension. Comparative study of CT with percutaneous transhepatic portography

    Energy Technology Data Exchange (ETDEWEB)

    Iida, Akihiko; Sano, Akira; Imanaka, Kazufumi; Nishizawa, Sadahiko; Sasai, Keisuke

    1984-08-01

    This paper deals with the diagnostic capability of CT scan for hepatofugal collaterals in 22 patients with portal hypertension. The patients studied were those who underwent percutaneous transhepatic portography (PTP) and CT scan within a short period. Each collateral vein demonstrated by PTP was classified into three grades according to its caliber (d): (1) Grade I, d<5mm, (2) Grade II, 5mm

  13. Atom probe tomographic studies of precipitation in Al-0.1Zr-0.1Ti (at.%) alloys.

    Science.gov (United States)

    Knipling, Keith E; Dunand, David C; Seidman, David N

    2007-12-01

    Atom probe tomography was utilized to measure directly the chemical compositions of Al(3)(Zr(1)-(x)Ti(x)) precipitates with a metastable L1(2) structure formed in Al-0.1Zr-0.1Ti (at.%) alloys upon aging at 375 degrees C or 425 degrees C. The alloys exhibit an inhomogeneous distribution of Al(3)(Zr(1)-(x)Ti(x)) precipitates, as a result of a nonuniform dendritic distribution of solute atoms after casting. At these aging temperatures, the Zr:Ti atomic ratio in the precipitates is about 10 and 5, respectively, indicating that Ti remains mainly in solid solution rather than partitioning to the Al(3)(Zr(1)-(x)Ti(x)) precipitates. This is interpreted as being due to the very small diffusivity of Ti in alpha-Al, consistent with prior studies on Al-Sc-Ti and Al-Sc-Zr alloys, where the slower diffusing Zr and Ti atoms make up a small fraction of the Al(3)(Zr(1)-(x)Ti(x)) precipitates. Unlike those alloys, however, the present Al-Zr-Ti alloys exhibit no interfacial segregation of Ti at the matrix/precipitate heterophase interface, a result that may be affected by a significant disparity in the evaporation fields of the alpha-Al matrix and Al(3)(Zr(1)-(x)Ti(x)) precipitates and/or a lack of local thermodynamic equilibrium at the interface.

  14. Distribution of skeletal muscle involvement in autosomal recessive distal muscular dystrophy. A clinical and computed tomographic study

    Energy Technology Data Exchange (ETDEWEB)

    Mizusawa, Hidehiro; Nakanishi, Takao; Kobayashi, Fumie

    1987-02-01

    Distribution of skeletal muscle involvement in 5 cases with autosomal recessive distal muscular dystrophy was studied clinically and by computed tomography (CT). Manual muscle test showed muscle involvement with a predilection for flexors in the lower leg and adductors in the thigh. Flexion and extension of the thigh and the lower leg was impaired to similar degree. In progressed cases, neck flexors and trunk muscles were also affected mildly. CT disclosed more clearly the preferential involvement of flexors in the lower leg, and involvement of both hamstrings center dot adductors group and extensors group of the thigh to similar degree. However, m. popliteus was curiously well preserved. In addition, there was a stage showing high density and hypertrophy of m. sartorius, m. gracilis, m. adductor, m. biceps femoris, m. semimenbranosus, m. semitendinosus or m. rectus femoris, which in thought to be compensatory hypertrophy. M. gluteus minimus in the pelvic girdle and m. dorsi proprii in the trunk were also liable to be affected. The CT findings are regarded as characteristic features noted clearly before muscle weakness and atrophy become apparent clinically. CT is very useful for distinguishing distal muscular dystrophy from rimmed vacuolar distal myopathy in which m. quadriceps femoris and flexors of the lower leg are usually well preserved without compensatory hypertrophy on CT.

  15. Bone thickness of the infrazygomatic crest area in skeletal Class III growing patients: A computed tomographic study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyub Soo; Choi, Hang Moon; Choi, Dong Soon; Jang, Insan; Cha, Bong Kuen [College of Dentistry and Research Institute of Oral Science, Gangneung-Wonju National University, Gangneung (Korea, Republic of)

    2013-12-15

    This study was performed to investigate the bone thickness of the infrazygomatic crest area by computed tomography (CT) for placement of a miniplate as skeletal anchorage for maxillary protraction in skeletal Class III children. CT images of skeletal Class III children (7 boys, 9 girls, mean age: 11.4 years) were taken parallel to the Frankfurt horizontal plane. The bone thickness of the infrazygomatic crest area was measured at 35 locations on the right and left sides, perpendicular to the bone surface. The bone was thickest (5.0 mm) in the upper zygomatic bone and thinnest (1.1 mm) in the anterior wall of the maxillary sinus. Generally, there was a tendency for the bone to be thicker at the superior and lateral area of the zygomatic process of the maxilla. There was no clinically significant difference in bone thickness between the right and left sides; however, it was thicker in male than in female subjects. In the infrazygomatic crest area, the superior and lateral area of the zygomatic process of the maxilla had the most appropriate thickness for placement of a miniplate in growing skeletal Class III children with a retruded maxilla.

  16. Bone thickness of the infrazygomatic crest area in skeletal Class III growing patients: A computed tomographic study

    International Nuclear Information System (INIS)

    Lee, Hyub Soo; Choi, Hang Moon; Choi, Dong Soon; Jang, Insan; Cha, Bong Kuen

    2013-01-01

    This study was performed to investigate the bone thickness of the infrazygomatic crest area by computed tomography (CT) for placement of a miniplate as skeletal anchorage for maxillary protraction in skeletal Class III children. CT images of skeletal Class III children (7 boys, 9 girls, mean age: 11.4 years) were taken parallel to the Frankfurt horizontal plane. The bone thickness of the infrazygomatic crest area was measured at 35 locations on the right and left sides, perpendicular to the bone surface. The bone was thickest (5.0 mm) in the upper zygomatic bone and thinnest (1.1 mm) in the anterior wall of the maxillary sinus. Generally, there was a tendency for the bone to be thicker at the superior and lateral area of the zygomatic process of the maxilla. There was no clinically significant difference in bone thickness between the right and left sides; however, it was thicker in male than in female subjects. In the infrazygomatic crest area, the superior and lateral area of the zygomatic process of the maxilla had the most appropriate thickness for placement of a miniplate in growing skeletal Class III children with a retruded maxilla.

  17. Plaque disruption by coronary computed tomographic angiography in stable patients vs. acute coronary syndrome: a feasibility study.

    Science.gov (United States)

    Bilolikar, Abhay N; Goldstein, James A; Madder, Ryan D; Chinnaiyan, Kavitha M

    2016-03-01

    This study was designed to determine whether coronary CT angiography (CTA) can detect features of plaque disruption in clinically stable patients and to compare lesion prevalence and features between stable patients and those with acute coronary syndrome (ACS). We retrospectively identified patients undergoing CTA, followed by invasive coronary angiography (ICA) within 60 days. Quantitative 3-vessel CTA lesion analysis was performed on all plaques ≥25% stenosis to assess total plaque volume, low attenuation plaque (LAP, disruption, including ulceration and intra-plaque dye penetration (IDP). ICA was employed as a reference standard for disruption. A total of 145 (94 ACS and 51 stable) patients were identified. By CTA, plaque disruption was evident in 77.7% of ACS cases. Although more common among those with ACS, CTA also detected plaque disruption in 37.3% of clinically stable patients (P disruption as determined by CTA. Though the prevalence of plaque disruption is less than patients with ACS, these findings support the concept that some clinically stable patients may harbour 'silent' disrupted plaques. These findings may have implications for detection of 'at risk' plaques and patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  18. Computer tomographic investigation of ancient Egyptian mummies

    International Nuclear Information System (INIS)

    Huebner, K.H.; Pahl, W.M.; Tuebingen Univ.

    1981-01-01

    Radiological and computer tomographic examinations of Egyptian mummies have been carried out at the Institute of Anthropology and Human Genetics from 1975 to 1978. These have demonstrated the value of CT in medical archaeology. It enables one to study the soft tissues, the skin (if bandaged), the muscles and any organs retained in situ for magical or religious reason. Measurements of attenuation values indicate the materials which were used for mummifying the skin and organs. Characteristic examples are described and the early results of these examinations are discussed. (orig.) [de

  19. Computer tomographic investigation of ancient Egyptian mummies

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, K H; Pahl, W M

    1981-08-01

    Radiological and computer tomographic examinations of Egyptian mummies have been carried out at the Institute of Anthropology and Human Genetics from 1975 to 1978. These have demonstrated the value of CT in medical archaeology. It enables one to study the soft tissues, the skin (if bandaged), the muscles and any organs retained in situ for magical or religious reason. Measurements of attenuation values indicate the materials which were used for mummifying the skin and organs. Characteristic examples are described and the early results of these examinations are discussed.

  20. An intragastric trichobezoar: computerised tomographic appearance.

    Directory of Open Access Journals (Sweden)

    Morris B

    2000-04-01

    Full Text Available A 26-year-old lady presented with a history of abdominal pain and distension since two months. The ultrasound examination showed an epigastric mass, which was delineated as a filling defect in the stomach on barium studies. The computerised tomographic scan showed a gastric mass with pockets of air in it, without post-contrast enhancement. This case highlights the characteristic appearance on computerised tomography of a bezoar within the stomach, a feature that is not commonly described in medical literature.

  1. A Study on GPU-based Iterative ML-EM Reconstruction Algorithm for Emission Computed Tomographic Imaging Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Woo Seok; Kim, Soo Mee; Park, Min Jae; Lee, Dong Soo; Lee, Jae Sung [Seoul National University, Seoul (Korea, Republic of)

    2009-10-15

    The maximum likelihood-expectation maximization (ML-EM) is the statistical reconstruction algorithm derived from probabilistic model of the emission and detection processes. Although the ML-EM has many advantages in accuracy and utility, the use of the ML-EM is limited due to the computational burden of iterating processing on a CPU (central processing unit). In this study, we developed a parallel computing technique on GPU (graphic processing unit) for ML-EM algorithm. Using Geforce 9800 GTX+ graphic card and CUDA (compute unified device architecture) the projection and backprojection in ML-EM algorithm were parallelized by NVIDIA's technology. The time delay on computations for projection, errors between measured and estimated data and backprojection in an iteration were measured. Total time included the latency in data transmission between RAM and GPU memory. The total computation time of the CPU- and GPU-based ML-EM with 32 iterations were 3.83 and 0.26 sec, respectively. In this case, the computing speed was improved about 15 times on GPU. When the number of iterations increased into 1024, the CPU- and GPU-based computing took totally 18 min and 8 sec, respectively. The improvement was about 135 times and was caused by delay on CPU-based computing after certain iterations. On the other hand, the GPU-based computation provided very small variation on time delay per iteration due to use of shared memory. The GPU-based parallel computation for ML-EM improved significantly the computing speed and stability. The developed GPU-based ML-EM algorithm could be easily modified for some other imaging geometries

  2. A Study on GPU-based Iterative ML-EM Reconstruction Algorithm for Emission Computed Tomographic Imaging Systems

    International Nuclear Information System (INIS)

    Ha, Woo Seok; Kim, Soo Mee; Park, Min Jae; Lee, Dong Soo; Lee, Jae Sung

    2009-01-01

    The maximum likelihood-expectation maximization (ML-EM) is the statistical reconstruction algorithm derived from probabilistic model of the emission and detection processes. Although the ML-EM has many advantages in accuracy and utility, the use of the ML-EM is limited due to the computational burden of iterating processing on a CPU (central processing unit). In this study, we developed a parallel computing technique on GPU (graphic processing unit) for ML-EM algorithm. Using Geforce 9800 GTX+ graphic card and CUDA (compute unified device architecture) the projection and backprojection in ML-EM algorithm were parallelized by NVIDIA's technology. The time delay on computations for projection, errors between measured and estimated data and backprojection in an iteration were measured. Total time included the latency in data transmission between RAM and GPU memory. The total computation time of the CPU- and GPU-based ML-EM with 32 iterations were 3.83 and 0.26 sec, respectively. In this case, the computing speed was improved about 15 times on GPU. When the number of iterations increased into 1024, the CPU- and GPU-based computing took totally 18 min and 8 sec, respectively. The improvement was about 135 times and was caused by delay on CPU-based computing after certain iterations. On the other hand, the GPU-based computation provided very small variation on time delay per iteration due to use of shared memory. The GPU-based parallel computation for ML-EM improved significantly the computing speed and stability. The developed GPU-based ML-EM algorithm could be easily modified for some other imaging geometries

  3. Computerized operator decision aids

    International Nuclear Information System (INIS)

    Long, A.B.

    1984-01-01

    This article explores the potential benefits associated with the use of computers in nuclear plants by the operating crew as an aid in making decisions. Pertinent findings are presented from recently completed projects to establish the context in which operating decisions have to be made. Key factors influencing the decision-making process itself are also identified. Safety parameter display systems, which are being implemented in various forms by the nuclear industry, are described within the context of decision making. In addition, relevant worldwide research and development activities are examined as potential enhancements to computerized operator decision aids to further improve plant safety and availability

  4. Computerized procedures system

    Science.gov (United States)

    Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.

    2010-10-12

    An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

  5. Performance of analytical methods for tomographic gamma scanning

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Mercer, D.J.

    1997-01-01

    The use of gamma-ray computerized tomography for nondestructive assay of radioactive materials has led to the development of specialized analytical methods. Over the past few years, Los Alamos has developed and implemented a computer code, called ARC-TGS, for the analysis of data obtained by tomographic gamma scanning (TGS). ARC-TGS reduces TGS transmission and emission tomographic data, providing the user with images of the sample contents, the activity or mass of selected radionuclides, and an estimate of the uncertainty in the measured quantities. The results provided by ARC-TGS can be corrected for self-attenuation when the isotope of interest emits more than one gamma-ray. In addition, ARC-TGS provides information needed to estimate TGS quantification limits and to estimate the scan time needed to screen for small amounts of radioactivity. In this report, an overview of the analytical methods used by ARC-TGS is presented along with an assessment of the performance of these methods for TGS

  6. A study of root canal morphology of human primary incisors and molars using cone beam computerized tomography: An in vitro study

    Directory of Open Access Journals (Sweden)

    Vivek Gaurav

    2013-01-01

    Full Text Available Background: Variations in morphology of root canals in primary teeth usually leads to complications during and after endodontic therapy. To improve the success in endodontics, a thorough knowledge of the root canal morphology is essential. Aim: The aim of this study was to assess the variation in number and morphology of the root canals of primary incisors and molars and to study the applicability of cone beam computerized tomography (CBCT in assessing the same. Settings and Design: A total of 60 primary molars and incisors with full root length were collected and various parameters such as the number of roots, number of canals, diameter of root canal at cementoenamel junction and middle-third, length and angulations of roots of primary molars and incisors were studied using CBCT. Statistical analysis used: The observations were put to descriptive statistics to find out the frequency, mean, standard deviation and range for all four subgroups. Further, unpaired t-test was used to compare these parameters between subgroups and analysis of variance test was implemented to evaluate the parameters within the subgroups. Results and Conclusion: The CBCT showed the presence of bifurcation of root canal at middle third in 13% of mandibular incisors while 20% of mandibular molars had two canals in distal root. The diameter of distobuccal root canal of maxillary molars and mesiolingual canal of mandibular molars was found to be minimum. CBCT is a relatively new and effective technology, which provides an auxiliary imaging modality to supplement conventional radiography for assessing the variation in root canal morphology of primary teeth.

  7. Computerized adaptive testing item selection in computerized adaptive learning systems

    NARCIS (Netherlands)

    Eggen, Theodorus Johannes Hendrikus Maria; Eggen, T.J.H.M.; Veldkamp, B.P.

    2012-01-01

    Item selection methods traditionally developed for computerized adaptive testing (CAT) are explored for their usefulness in item-based computerized adaptive learning (CAL) systems. While in CAT Fisher information-based selection is optimal, for recovering learning populations in CAL systems item

  8. Computed tomographic appearances of cherubism

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, S D; Boccardi, A; Mela, F; Romagnoli, R

    1987-01-01

    The computed tomographic (CT) aspects of six cases of cherubism are described. Through its optimal representation of the lesions, CT enabled certain characteristics of this disease to be substantiated, namely, limitation of the process to the bones of the jaw and primarily superficial development of the mandibular lesions, coupled with an unusual mandibular condylar impairment. Moreover, the composition of this series permitted investigation of the condition in its several stages of progression.

  9. Automated angular and translational tomographic alignment and application to phase-contrast imaging

    DEFF Research Database (Denmark)

    Cunha Ramos, Tiago Joao; Jørgensen, Jakob Sauer; Andreasen, Jens Wenzel

    2017-01-01

    X-ray computerized tomography (CT) is a 3D imaging technique that makes use of x-ray illumination and image reconstruction techniques to reproduce the internal cross-sections of a sample. Tomographic projection data usually require an initial relative alignment or knowledge of the exact object po...... improvement in the reconstruction resolution. A MATLAB implementation is made publicly available and will allow robust analysis of large volumes of phase-contrast tomography data.......X-ray computerized tomography (CT) is a 3D imaging technique that makes use of x-ray illumination and image reconstruction techniques to reproduce the internal cross-sections of a sample. Tomographic projection data usually require an initial relative alignment or knowledge of the exact object...... reconstruction artifacts and limit the attained resolution in the final tomographic reconstruction. Alignment algorithms that require manual interaction impede data analysis with ever-increasing data acquisition rates, supplied by more brilliant sources. We present in this paper an iterative reconstruction...

  10. Correlation of tomographic findings with pulmonary function parameters in nonsmoking patients with idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Lopes, Agnaldo Jose; Capone, Domenico; Mogami, Roberto; Jansen, Jose Manoel .E mail: phel.lop@uol.com.br; Cunha, Daniel Leme da; Melo, Pedro Lopes de

    2007-01-01

    Objective: To correlate tomographic findings with pulmonary function parameters in patients with idiopathic pulmonary fibrosis (IPF). Methods: A cross-sectional study was carried out, in which 30 nonsmoking patients with IPF were evaluated. Using a semiquantitative scoring system, the following high-resolution computerized tomography findings were quantified: total interstitial disease (TID), reticular abnormality/honeycombing, and ground-glass opacity (GGO). The functional variables were measured by spirometry, forced oscillation technique (FOT), helium dilution method, as well as the single-breath method of measuring diffusion capacity of the lung for carbon monoxide (DLCO). Results: Of the 30 patients studied, 18 were female, and 12 were male, with a mean age of 70.9 years. We found that TID and reticular abnormality and honeycombing correlated significantly (negative correlations) with the measurements of forced vital capacity (FVC), total lung capacity (TLC), DLCO, and dynamic respiratory compliance were found, as well as that GGO correlated significantly (and positively) with residual volume/TLC. The ratio of forced expiratory flow between 25 and 75% of FVC to FVC (FEF25-75%/FVC) correlated positively with TID, reticular abnormality/honeycombing, and GGO. Conclusion: In IPF patients, the measurements of volume, diffusion, and dynamic compliance are the physiological variables which best reflect the extent of the interstitial disease on HRCT scans. (author)

  11. Correlation of tomographic findings with pulmonary function parameters in nonsmoking patients with idiopathic pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Agnaldo Jose; Capone, Domenico; Mogami, Roberto; Jansen, Jose Manoel [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). School of Medical Sciences].E mail: phel.lop@uol.com.br; Cunha, Daniel Leme da [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Pedro Ernesto University Hospital. Dept. of Radiology and Diagnostic Imaging; Melo, Pedro Lopes de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. of Biology

    2007-11-15

    Objective: To correlate tomographic findings with pulmonary function parameters in patients with idiopathic pulmonary fibrosis (IPF). Methods: A cross-sectional study was carried out, in which 30 nonsmoking patients with IPF were evaluated. Using a semiquantitative scoring system, the following high-resolution computerized tomography findings were quantified: total interstitial disease (TID), reticular abnormality/honeycombing, and ground-glass opacity (GGO). The functional variables were measured by spirometry, forced oscillation technique (FOT), helium dilution method, as well as the single-breath method of measuring diffusion capacity of the lung for carbon monoxide (DLCO). Results: Of the 30 patients studied, 18 were female, and 12 were male, with a mean age of 70.9 years. We found that TID and reticular abnormality and honeycombing correlated significantly (negative correlations) with the measurements of forced vital capacity (FVC), total lung capacity (TLC), DLCO, and dynamic respiratory compliance were found, as well as that GGO correlated significantly (and positively) with residual volume/TLC. The ratio of forced expiratory flow between 25 and 75% of FVC to FVC (FEF25-75%/FVC) correlated positively with TID, reticular abnormality/honeycombing, and GGO. Conclusion: In IPF patients, the measurements of volume, diffusion, and dynamic compliance are the physiological variables which best reflect the extent of the interstitial disease on HRCT scans. (author)

  12. Correction of ring artifacts in X-ray tomographic images

    DEFF Research Database (Denmark)

    Lyckegaard, Allan; Johnson, G.; Tafforeau, P.

    2011-01-01

    Ring artifacts are systematic intensity distortions located on concentric circles in reconstructed tomographic X-ray images. When using X-ray tomography to study for instance low-contrast grain boundaries in metals it is crucial to correct for the ring artifacts in the images as they may have...... the same intensity level as the grain boundaries and thus make it impossible to perform grain segmentation. This paper describes an implementation of a method for correcting the ring artifacts in tomographic X-ray images of simple objects such as metal samples where the object and the background...... are separable. The method is implemented in Matlab, it works with very little user interaction and may run in parallel on a cluster if applied to a whole stack of images. The strength and robustness of the method implemented will be demonstrated on three tomographic X-ray data sets: a mono-phase β...

  13. Organization-wide adoption of computerized provider order entry systems: a study based on diffusion of innovations theory.

    Science.gov (United States)

    Rahimi, Bahlol; Timpka, Toomas; Vimarlund, Vivian; Uppugunduri, Srinivas; Svensson, Mikael

    2009-12-31

    Computerized provider order entry (CPOE) systems have been introduced to reduce medication errors, increase safety, improve work-flow efficiency, and increase medical service quality at the moment of prescription. Making the impact of CPOE systems more observable may facilitate their adoption by users. We set out to examine factors associated with the adoption of a CPOE system for inter-organizational and intra-organizational care. The diffusion of innovation theory was used to understand physicians' and nurses' attitudes and thoughts about implementation and use of the CPOE system. Two online survey questionnaires were distributed to all physicians and nurses using a CPOE system in county-wide healthcare organizations. The number of complete questionnaires analyzed was 134 from 200 nurses (67.0%) and 176 from 741 physicians (23.8%). Data were analyzed using descriptive-analytical statistical methods. More nurses (56.7%) than physicians (31.3%) stated that the CPOE system introduction had worked well in their clinical setting (P system not adapted to their specific professional practice (P = system (P = 0.041). We found that in particular the received relative advantages of the CPOE system were estimated to be significantly (P systems are introduced as a response to the present limitations in paper-based systems. In consequence, user expectations are often high on their relative advantages as well as on a low level of complexity. Building CPOE systems therefore requires designs that can provide rather important additional advantages, e.g. by preventing prescription errors and ultimately improving patient safety and safety of clinical work. The decision-making process leading to the implementation and use of CPOE systems in healthcare therefore has to be improved. As any change in health service settings usually faces resistance, we emphasize that CPOE system designers and healthcare decision-makers should continually collect users' feedback about the systems, while

  14. Computerized tomography of the pancreas

    International Nuclear Information System (INIS)

    Dondelinger, R.; Campos, R.O.; Lamarque, J.L.

    1979-01-01

    Pancreatic anatomy is briefly reviewed. Tomographic images from normal pancreas and from pathological states (different kinds of pancreatitis; pancreatic tumors) of this organ are discussed. (M.A.) [pt

  15. OPTIMALISASI KINERJA PERSEDIAAN SUKU CADANG UNTUK PELAKSANAAN MAINTENANCE REPAIR OVERHAUL (MRO DENGAN PENERAPAN COMPUTERIZED MAINTENANCE MANAGEMENT SYSTEMS (CMMS (Studi Kasus di PT. Indonesia Asahan Aluminium

    Directory of Open Access Journals (Sweden)

    Sutrisno Sutrisno

    2015-04-01

    Full Text Available PT.Inalum is a manufacturing company engaged in the aluminum smelting industry. PT.Inalum pengendaliaan system requires an inventory of spare parts to conduct maintenance, repair and overhaul (MRO. CMMS (Computerized Maintenance Management System is a computerized maintenance system running on a LAN (Local Area Network. CMMS is influenced by three variables, namely an integrated maintenance, inventory and procurement so as to create a good maintenance should be supported by the inventory control of spare parts used in maintenance. CMMS aims to make the work more efficient and effective, especially in matters relating to maintenance. That as a benchmark to measure the performance of CMMs for spare parts inventory control is a key performance indicator (KPI. This study aims to evaluate and compare key performance indicators before and after implementation of CMMS for the implementation of MRO activities. Another goal to be achieved is to determine the factors that affect the value of the inventory of spare parts. Based on the results of data processing and analysis can be seen that by looking at a comparison of before and after implementation of CMMS on key performance indicators, it appears that there is an improvement in every parameter, one of which is the value of the inventory prior to the implementation of CMMS for $ 34,790,000.00 compared to after the application of the inventory value fell to $ 19,632,000.00. Factors that affect the value of the inventory is the inventory of spare parts, maintenance, procurement, and human resources.

  16. Robinson's Computerized Strabismus Model Comes of Age

    NARCIS (Netherlands)

    H.J. Simonsz (Huib); H. Spekreijse (Henk)

    1996-01-01

    textabstractIn this article we review our further development of D.A. Robinson's computerized strabismus model. First, an extensive literature study has been carried out to get more accurate data on the anatomy of the average eye and the eye muscles, and about how these vary with age and with

  17. The limited angle problem in computerized tomography

    International Nuclear Information System (INIS)

    Louis, A.K.

    1984-01-01

    Fast reconstruction formulae in X-ray computerized tomography demand the directions, in which the measurements are taken, to be equally distributed over the whole circle. In many applications data can only be provided in a restricted range. Here the intrinsic difficulties are studied by giving a singular value decomposition of the Radon transform in a restricted range. Practical limitations are deduced. (orig.)

  18. Ethics and the Computerization of Pharmacy.

    Science.gov (United States)

    McCarthy, Robert L.; Perrolle, Judith A.

    1991-01-01

    The current and potential impact of computerization on pharmacy practice is discussed, focusing on ethical dilemmas in the pharmacist-patient relationship, confidentiality of records, and the role of artificial intelligence in decision making about drug therapy. Case studies for use by teachers of pharmaceutical ethics are provided. (Author/MSE)

  19. Computerized management support for swine breeding farms

    NARCIS (Netherlands)

    Huirne, R.B.M.

    1990-01-01

    1. INTRODUCTION

    The investigations described in this thesis have been directed towards computerized management support for swine breeding farms, focused on sow productivity and profitability. The study is composed of three basic parts: (1) basic description and

  20. Radio tomographic imaging of sporadic-E layers during SEEK-2

    Directory of Open Access Journals (Sweden)

    P. A. Bernhardt

    2005-10-01

    Full Text Available During the SEEK-2 Rocket Campaign in August 2002, a Dual Band Beacon (DBB transmitting to Ground Receivers provided unique data on E-Region electron densities. Information from two rocket beacons and four ground receivers yielded multiple samples of E-region horizontal and vertical variations. The radio beacon measurements were made at four sites (Uchinoura, Tarumizu, Tanegashima, Takazaki in Japan for two rockets (S310-31 and S310-32 launched by the Institute of Space and Aeronautical Science (ISAS. Analysis was completed for four sets of beacon data to provide electron density images of sporadic-E layers. Signals from the two-frequency beacons on the SEEK-2 rockets were processed to yield total electron content (TEC data that was converted into electron density measurements. Wide variations in layer structures were detected. These included horizontal sporadic-E variations, vertical profiles of double, single, and weak layers. The radio beacon measurements were shown to be in agreement with the in-situ SEEK-2 sensors. The first tomographic image of a sporadic-E layer was produced from the data. The rocket beacon technique was shown to be an excellent tool to study sporadic-E layers because absolute TEC accuracy of 0.01 TEC Units can be easily obtained and, with proper receiver placement, electron density images can be produced using computerized ionospheric tomography with better than 1km horizontal and vertical resolution. Keywords. Ionospheric irregularities – Instruments and techniques – Mid-latitude ionosphere

  1. Caveats on tomographic images

    DEFF Research Database (Denmark)

    Foulger, Gillian R.; Panza, Giuliano F.; Artemieva, Irina

    2014-01-01

    )CNR – Istituto di Geologia Ambientale e Geoingegneria (IGAG) c/o Dipartimento di Scienze della Terra, Università degliStudi di Roma La Sapienza, Rome, Italy, (10) Dept. Physics of the Earth, Sankt-Petersburg State University, Sankt-Petersburg,RussiaGeological models of the mantle and its geodynamic...

  2. Tomographic PIV: principles and practice

    International Nuclear Information System (INIS)

    Scarano, F

    2013-01-01

    A survey is given of the major developments in three-dimensional velocity field measurements using the tomographic particle image velocimetry (PIV) technique. The appearance of tomo-PIV dates back seven years from the present review (Elsinga et al 2005a 6th Int. Symp. PIV (Pasadena, CA)) and this approach has rapidly spread as a versatile, robust and accurate technique to investigate three-dimensional flows (Arroyo and Hinsch 2008 Topics in Applied Physics vol 112 ed A Schröder and C E Willert (Berlin: Springer) pp 127–54) and turbulence physics in particular. A considerable number of applications have been achieved over a wide range of flow problems, which requires the current status and capabilities of tomographic PIV to be reviewed. The fundamental aspects of the technique are discussed beginning from hardware considerations for volume illumination, imaging systems, their configurations and system calibration. The data processing aspects are of uppermost importance: image pre-processing, 3D object reconstruction and particle motion analysis are presented with their fundamental aspects along with the most advanced approaches. Reconstruction and cross-correlation algorithms, attaining higher measurement precision, spatial resolution or higher computational efficiency, are also discussed. The exploitation of 3D and time-resolved (4D) tomographic PIV data includes the evaluation of flow field pressure on the basis of the flow governing equation. The discussion also covers a-posteriori error analysis techniques. The most relevant applications of tomo-PIV in fluid mechanics are surveyed, covering experiments in air and water flows. In measurements in flow regimes from low-speed to supersonic, most emphasis is given to the complex 3D organization of turbulent coherent structures. (topical review)

  3. Segmentation-DrivenTomographic Reconstruction

    DEFF Research Database (Denmark)

    Kongskov, Rasmus Dalgas

    such that the segmentation subsequently can be carried out by use of a simple segmentation method, for instance just a thresholding method. We tested the advantages of going from a two-stage reconstruction method to a one stage segmentation-driven reconstruction method for the phase contrast tomography reconstruction......The tomographic reconstruction problem is concerned with creating a model of the interior of an object from some measured data, typically projections of the object. After reconstructing an object it is often desired to segment it, either automatically or manually. For computed tomography (CT...

  4. Ovarian metastases: Computed tomographic appearances

    International Nuclear Information System (INIS)

    Megibow, A.J.; Hulnick, D.H.; Bosniak, M.A.; Balthazar, E.J.

    1985-01-01

    Computed tomographic scans of 34 patients with ovarian metastases were reviewed to assess the radiographic appearances and to correlate these with the primary neoplasms. Primary neoplasms were located in the colon (20 patients), breast (six), stomach (five), small bowel (one), bladder (one), and Wilms tumor of the kidney (one). The radiographic appearance of the metastatic lesions could be described as predominantly cystic (14 lesions), mixed (12 lesions), or solid (seven lesions). The cystic and mixed lesions tended to be larger in overall diameter than the solid. The metastases from gastric carcinoma appeared solid in four of five cases. The metastases from the other neoplasms had variable appearances simulating primary ovarian carcinoma

  5. Neuroblastoma: computed tomographic findings

    International Nuclear Information System (INIS)

    Yoon, Choon Sik; Ahn, Chang Su; Kim, Myung Jun; Oh, Ki Keun

    1994-01-01

    To evaluate the characteristic CT findings of neuroblastoma, we studied neuroblastomas. We analysed CT findings of available 25 cases among pathologically proved 51 neuroblastomas from Jan. 1983 to Sept. 1990. The most frequent site of origin is adrenal gland (40%) and the second is retroperitoneum (32%) and the third ismediastinum (16%). Characteristic CT findings are as follows: Calcifications within the tumor is detected in 86% of abdominal neuroblastomas and 50% of mediastinal origin. Hemorrhagic and necrotic changes within the tumor is noted at 86% in the tumor of abdominal origin and 25% in mediastinal neuroblastomas. Contrast enhanced study showed frequently seperated enhanced appearance with/without solid contrast enhancement. Encasements of major great vessels such as aorta and IVC with/without displacement by metastatic lymph nodes or tumor are frequently seen in 90% of abdominal neuroblastomas. Multiple lymphadenopathy are detected in 95% of abdominal neuroblastomas and 25% of mediastinal neuroblastomas. The most common organ or contiguous direct invasion is kidney in 6 cases and the next one is liver but intraspinal canal invasion is also noted in 2 cases. We concluded that diagnosis of neuroblastoma would be easily obtained in masses of pediatric group from recognition of above characteristic findings

  6. Combined study of 99mTc-HMPAO SPECT and computerized electroencephalographic topography (CET) in patients with medically refractory complex partial epilepsy

    International Nuclear Information System (INIS)

    Rodrigues, M.; Botelho, M.M.; Fonseca, A.T.; Peter, J.P.; Pimentel, T.; Vieira, M.R.

    1996-01-01

    For successful surgery for drug-resistant partial epilepsy the site of the seizure focus needs to be known exactly. The purpose of this study was to compare the evaluation of the regional cerebral blood flow (rCBF) (localization and degree of disturbances) by 99m Tc-hexamethylpropylene-amineoxime (HMPAO) single photon emission computed tomography (SPECT) with computerized electroencephalographic topography (CET) and transmission computed X-ray tomography (CT) in partial epilepsy. The study included 20 patients with medically refractory complex partial seizures. Of the 20 patients included, 15 were studied interictally, four ictally and one in both states, interictally and ictally. 99m Tc-HMPAO SPECT detected rCBF changes in 95% of the patients. Interictal studies demonstrated focal areas of hypoperfusion in 93% of the patients. Ictal studies demonstrated an area of hyperperfusion in all patients. Blood flow disturbances in deeper structures of the brain, such as basal ganglia, could be detected. The areas with abnormal 99m Tc-HMPAO uptake were concordant, in localization, with CET in 85% of the patients. Abnormal data with CT scans were found in only 45% of the patients. Focal lesions were found in 20% of the patients by CT scans. 99m Tc-HMPAO SPECT combined with CET may be a useful screening procedure prior to referral for invasive diagnostic procedures in future management of patients with medically refractory complex partial seizures. (author)

  7. Effect of computerized cognitive training with virtual spatial navigation task during bed rest immobilization and recovery on vascular function: A pilot study

    Directory of Open Access Journals (Sweden)

    Goswami N

    2015-02-01

    Full Text Available Nandu Goswami,1 Voyko Kavcic,2 Uros Marusic,3 Bostjan Simunic,3 Andreas Rössler,1 Helmut Hinghofer-Szalkay,1 Rado Pisot3 1Institute of Physiology, Medical University of Graz, Graz, Austria; 2Institute of Gerontology, Wayne State University, Detroit, MI, USA; 3Institute for Kinesiology Research, University of Primorska, Ankaran, Slovenia Abstract: We investigated the effects of bed rest (BR immobilization, with and without computerized cognitive training with virtual spatial navigation task (CCT, on vascular endothelium on older subjects. The effects of 14-day BR immobilization in healthy older males (n=16 of ages 53–65 years on endothelial function were studied using EndoPAT®, a noninvasive and user-independent method. From the group of 16 older men, 8 randomly received CCT during the BR, using virtual navigation tasks in a virtual environment with joystick device. In all the cases, EndoPAT assessments were done at pre- and post-BR immobilization as well as following 28 days of ambulatory recovery. The EndoPAT index increased from 1.53±0.09 (mean ± standard error of the mean at baseline to 1.61±0.16 following immobilization (P=0.62 in the group with CCT. The EndoPAT index decreased from 2.06±0.13 (mean ± standard error of the mean at baseline to 1.70±0.09 at the last day of BR study, day 14 (BR14 (P=0.09 in the control group. Additionally, there were no statistically significant differences between BR14 and at 28 days of follow-up (rehabilitation program (R28. Our results show a trend of immobilization in older persons affecting the vasoconstrictory endothelial response. As the control subjects had a greater increase in EndoPAT index after R28 (+0.018 compared to subjects who had cognitive training (+0.11 (calculated from the first day of BR study, it is possible that cognitive training during BR does not improve endothelial function but rather contributes to slowing down the impairment of endothelial function. Finally, our results

  8. Precision of quantum tomographic detection of radiation

    Energy Technology Data Exchange (ETDEWEB)

    D' Ariano, G.M. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy) Istituto Nazionale di Fisica Nucleare, Sezione di Pavia, Via A. Bassi 6, I-27100, Pavia (Italy)); Macchiavello, Chiara (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy)); Paris, M.G.A. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy))

    1994-11-21

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  9. Precision of quantum tomographic detection of radiation

    International Nuclear Information System (INIS)

    D'Ariano, G.M.; Macchiavello, Chiara; Paris, M.G.A.

    1994-01-01

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  10. Computerized tomography in myotonic dystrophy

    International Nuclear Information System (INIS)

    Gellerich, I.; Mueller, D.; Koch, R.D.

    1986-01-01

    Besides clinical symptoms, progress and electromyography computerized tomography improves the diagnostics of myotonic dystrophy. Even small changes in muscular structure are detectable and especially the musculus soleus exhibits early and pronounced alterations. By means of density distribution pattern an improved characterization of the disease is possible. Additional information is obtained by cerebral computerized tomography. Atrophy of brain tissue is to be expected in all patients with myotonic dystrophy. (author)

  11. Computerized radiation treatment planning

    International Nuclear Information System (INIS)

    Laarse, R. van der.

    1981-01-01

    Following a general introduction, a chain consisting of three computer programs which has been developed for treatment planning of external beam radiotherapy without manual intervention is described. New score functions used for determination of optimal incidence directions are presented and the calculation of the position of the isocentre for each optimum combination of incidence directions is explained. A description of how a set of applicators, covering fields with dimensions of 4 to 20 cm, for the 6 to 20 MeV electron beams of a MEL SL75-20 linear accelerator was developed, is given. A computer program for three dimensional electron beam treatment planning is presented. A microprocessor based treatment planning system for the Selectron remote controlled afterloading system for intracavitary radiotherapy is described. The main differences in treatment planning procedures for external beam therapy with neutrons instead of photons is discussed. A microprocessor based densitometer for plotting isodensity lines in film dosimetry is described. A computer program for dose planning of brachytherapy is presented. Finally a general discussion about the different aspects of computerized treatment planning as presented in this thesis is given. (Auth.)

  12. Radioactive waste computerized management

    International Nuclear Information System (INIS)

    Communaux, M.; Lantes, B.

    1993-01-01

    Since December 31, 1990, the management of the nuclear wastes for all the power stations has been computerized, using the DRA module of the Power Generation and Transmission Group's data processing master plan. So now EDF has a software package which centralizes all the data, enabling it to declare the characteristics of the nuclear wastes which are to be stored on the sites operated by the National Radioactive Waste Management Agency (ANDRA). Among other uses, this application makes it possible for EDF, by real time data exchange with ANDRA, to constitute an inventory of validated, shippable packs. It also constitutes a data base for all the wastes produced on the various sites. This application was developed to meet the following requirements: give the producers of radioactive waste a means to fully manage all the characteristics and materials that are necessary to condition their waste correctly; guarantee the traceability and safety of data and automatically assure the transmission of this data in real time between the producers and the ANDRA; give the Central Services of EDF an operation and statistical tool permitting an experienced feed-back based on the complete national production (single, centralized data base); and integrate the application within the products of the processing master plan in order to assure its maintenance and evolution

  13. Advanced Ultrasonic Tomograph of Children's Bones

    Science.gov (United States)

    Lasaygues, Philippe; Lefebvre, Jean-Pierre; Guillermin, Régine; Kaftandjian, Valérie; Berteau, Jean-Philippe; Pithioux, Martine; Petit, Philippe

    This study deals with the development of an experimental device for performing ultrasonic computed tomography (UCT) on bone in pediatric degrees. The children's bone tomographs obtained in this study, were based on the use of a multiplexed 2-D ring antenna (1 MHz and 3 MHz) designed for performing electronic and mechanical scanning. Although this approach is known to be a potentially valuable means of imaging objects with similar acoustical impedances, problems arise when quantitative images of more highly contrasted media such as bones are required. Various strategies and various mathematical procedures for modeling the wave propagation based on Born approximations have been developed at our laboratory, which are suitable for use with pediatric cases. Inversions of the experimental data obtained are presented.

  14. Experimental study of mechanisms of sand production using X-ray computerized tomography; Estudo experimental dos mecanismos da producao de areia empregando tomografia computadorizada de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Janaina B.; Vargas Junior, Euripedes [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. de Engenharia Civil; Barroso, Emilio V. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Geologia; Campos, Elisabete; Goncalves, Clemente; Tavares, Andre [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2004-07-01

    During productive phase of the well, many times there is simultaneous production of the solid particles detached from matrix of the reservoir rock. This phenomenon receives the name of the sand production. In this case stress and flow conditions around of the well are fundamental factors for deflagration of the process. Stress concentration in the wall of the well lead to the loss of cohesion between grains arising, consequently, a granular material region susceptible for dragging by seepage forces derived from fluid flow. The objective of this work was to perform sand production tests in Rio Bonito and synthetic sandstone samples using real-time X-Ray Computerized Tomography. The tests investigated the initial and the evolution of failure at the cavity wall of samples. These are initial stages of the sand production process. The analysis of the CT-scans obtained during tests allowed the visualization of breakouts and collapses of the wells. From studies more details were possible estimate the sand production and produce 3-D images of the propagation of the failure. (author)

  15. Randomized controlled trial of a 12-month computerized mindfulness-based intervention for obese patients with binge eating disorder: The MindOb study protocol.

    Science.gov (United States)

    Ruffault, Alexis; Carette, Claire; Lurbe I Puerto, Kàtia; Juge, Nicolas; Beauchet, Alain; Benoliel, Jean-Jacques; Lacorte, Jean-Marc; Fournier, Jean F; Czernichow, Sébastien; Flahault, Cécile

    2016-07-01

    Mindfulness-based interventions for healthy behaviors such as exercise and dietary modifications have aroused growing interest. This study aims to test the effectiveness of a mindfulness-based intervention for the reduction of impulsive eating and the improvement of motivation to exercise among obese individuals. One-hundred and twenty obese outpatients, aged 18 to 65years, diagnosed with a binge eating disorder, will be randomly assigned to one of the three following groups: mindfulness practice, sham meditation, or treatment as usual control. The tested intervention consists of a 1-year computerized mindfulness-based program. Mindfulness sessions are audio recordings that the patients are asked to listen to, 10min every day. Self-reported questionnaires measuring impulsive eating, motivation to exercise, physical activity level, mood, and mindfulness skills are filled in at baseline, 1, 6, and 12months. Physical activity, calories consumption, and biomarkers are measured with more objective measurement tools at baseline, 6months and 12months. Mindfulness, as both a de-automation element and as a moderator of motivation to exercise, can lead to the reduction of impulsive eating and also to an increase in levels of physical activity. These effects could cause weight loss in obese patients suffering from binge eating disorder. clinicaltrials.gov: NCT02571387. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. X-ray tomographic apparatus

    International Nuclear Information System (INIS)

    Walters, R.G.

    1982-01-01

    An x-ray tomographic system consists of a radiation source such as gamma or x radiation which produces a fan-shaped beam. The fan is wide enough to encompass the patient circle. The system further includes means for rotating the radiation source about the patient for less than a full rotation, and detectors for detecting the radiation at positions that surround the patient by 180 0 plus the angle of the fan beam plus the angle between adjacent fan detectors. Attenuation data from the detectors is sorted into detector fans of attenuation data, then processed. The convolved data is back-projected into an image memory and displayed on a video monitor

  17. Computerized data treatment technology

    International Nuclear Information System (INIS)

    Ferguson, R.B.; Maddox, J.H.; Wren, H.F.

    1977-01-01

    The Savannah River Laboratory (SRL) has accepted responsibility for a hydrogeochemical and stream-sediment reconnaissance in 25 eastern states as part of the National Uranium Resource Evaluation (NURE). SRL has developed a computerized program for recording, processing, updating, retrieving, and analyzing hydrogeochemical data from this reconnaissance. This program will handle an expected 150 million bytes of hydrogeochemical data from 150,000 to 200,000 sample sites over the next four years. The SRL--NURE hydrogeochemical data management system is written in FORTRAN IV for an IBM System 360/195 computer and is designed to easily accommodate changes in types of collected data and input format. As the data become available, they are accepted and combined with relevant data already in the system. SRL also developed a sample inventory and control system and a graphics and analysis system. The sample inventory and control system accounts for the movements of all samples and forms from initial receipt through final storage. Approximately six million sample movements are expected. The graphics and analysis system provides easily usable programs for reporting and interpreting data. Because of the large volume of data to be interpreted, the graphics and analysis system plays a central role in the hydrogeochemical program. Programs developed to provide two- and three-dimensional plots of sampled geographic areas show concentrations and locations of individual variables which are displayed and reproduced photographically. Pattern recognition techniques are also available, and they allow multivariate data to be categorized into ''clusters,'' which may indicate sites favorable for uranium exploration

  18. Tomographic anthropomorphic models. Pt. 1

    International Nuclear Information System (INIS)

    Veit, R.; Zankl, M.; Petoussi, N.; Mannweiler, E.; Drexler, G.; Williams, G.

    1989-01-01

    The first generation of heterogenoeous anthropomorphic mathematical models to be used in dose calculations was the MIRD-5 adult phantom, followed by the pediatric MIRD-type phantoms and by the GSF sex-specific phantoms ADAM and EVA. A new generation of realistic anthropomorphic models is now introduced. The organs and tissues of these models consist of a well defined number of volume elements (voxels), derived from computer tomographic (CT) data; consequently, these models were named voxel or tomographic models. So far two voxel models of real patients are available: one of an 8 week old baby and of a 7 year old child. For simplicity, the model of the baby will be referred to as BABY and that of the child as CHILD. In chapter 1 a brief literature review is given on the existing mathematical models and their applications. The reasons that lead to the construction of the new CT models is discussed. In chapter 2 the technique is described which allows to convert any physical object into computer files to be used for dose calculations. The technique which produces three dimensional reconstructions of high resolution is discussed. In chapter 3 the main characteristics of the models of the baby and child are given. Tables of organ masses and volumes are presented together with three dimensional images of some organs and tissues. A special mention is given to the assessment of bone marrow distribution. Chapter 4 gives a short description of the Monte Carlo code used in conjunction with the models to calculate organ and tissue doses resulting from photon exposures. Some technical details concerning the computer files which describe the models are also given. (orig./HP)

  19. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  20. Computerized tomography of gall bladder cancer

    International Nuclear Information System (INIS)

    Todua, F.I.; Karmazanovskij, G.G.

    1989-01-01

    The authors have summed up the experience in the use of computerized tomography (CT) in diagnosis of gall bladder cancer. The investigation of 17 patients with cancer of this site showed a high informative value of the method. A retrospective comparative study of the results of CT and surgical interventions was carried out. It has been concluded that CT makes it possible not only to diagnose malignant lesions of the bile ducts but also to assess a possible scope of a forthcoming operation

  1. Tomographical properties of uniformly redundant arrays

    International Nuclear Information System (INIS)

    Cannon, T.M.; Fenimore, E.E.

    1978-01-01

    Recent work in coded aperture imaging has shown that the uniformly redundant array (URA) can image distant planar radioactive sources with no artifacts. The performance of two URA apertures when used in a close-up tomographic imaging system is investigated. It is shown that a URA based on m sequences is superior to one based on quadratic residues. The m sequence array not only produces less obnoxious artifacts in tomographic imaging, but is also more resilient to some described detrimental effects of close-up imaging. It is shown that in spite of these close-up effects, tomographic depth resolution increases as the source is moved closer to the detector

  2. Computerized cognitive training in children and adolescents with attention deficit/hyperactivity disorder as add-on treatment to stimulants: feasibility study and protocol description

    Directory of Open Access Journals (Sweden)

    Virginia de Oliveira Rosa

    Full Text Available Abstract Background Cognitive training has received increasing attention as a non-pharmacological approach for the treatment of attention deficit/hyperactivity disorder (ADHD in children and adolescents. Few studies have assessed cognitive training as add-on treatment to medication in randomized placebo controlled trials. The purpose of this preliminary study was to explore the feasibility of implementing a computerized cognitive training program for ADHD in our environment, describe its main characteristics and potential efficacy in a small pilot study. Methods Six ADHD patients aged 10-12-years old receiving stimulants and presenting residual symptoms were enrolled in a randomized clinical trial to either a standard cognitive training program or a controlled placebo condition for 12 weeks. The primary outcome was core ADHD symptoms measured using the Swanson, Nolan and Pelham Questionnaire (SNAP-IV scale. Results We faced higher resistance than expected to patient enrollment due to logistic issues to attend face-to-face sessions in the hospital and to fill the requirement of medication status and absence of some comorbidities. Both groups showed decrease in parent reported ADHD symptoms without statistical difference between them. In addition, improvements on neuropsychological tests were observed in both groups – mainly on trained tasks. Conclusions This protocol revealed the need for new strategies to better assess the effectiveness of cognitive training such as the need to implement the intervention in a school environment to have an assessment with more external validity. Given the small sample size of this pilot study, definitive conclusions on the effects of cognitive training as add-on treatment to stimulants would be premature.

  3. The Impact of a Home-Based Computerized Cognitive Training Intervention on Fall Risk Measure Performance in Community Dwelling Older Adults, a Pilot Study.

    Science.gov (United States)

    Blackwood, J; Shubert, T; Fogarty, K; Chase, C

    2016-02-01

    Cognitive intervention studies have reported improvements in various domains of cognition as well as a transfer effect of improved function post training. Despite the availability of web based cognitive training programs, most intervention studies have been performed under the supervision of researchers. Therefore, the purpose of this study was to first, examine the feasibility of a six week home based computerized cognitive training (CCT) program in a group of community dwelling older adults and, second, to determine if a CCT program which focused on set shifting, attention, and visual spatial ability impacted fall risk measure performance. This pilot study used a pretest/posttest experimental design with randomization by testing site to an intervention or control group. Community dwelling older adults (mean age = 74.6 years) participated in either the control (N=25) or the intervention group (N=19). Intervention group subjects participated in 6 weeks of home based CCT 3x/week for an average of 23 minutes/session, using an online CCT program. Comparisons of mean scores on three measures of physical function (usual gait speed, five times sit to stand, timed up and go) were completed at baseline and week 7. Following the completion of an average of 18 sessions of CCT at home with good adherence (86%) and retention (92%) rates, a statistically significant difference in gait speed was found between groups with an average improvement of 0.14 m/s in the intervention group. A home based CCT program is a feasible approach to targeting cognitive impairments known to influence fall risk and changes in gait in older adults.

  4. Computerized cognitive training in children and adolescents with attention deficit/hyperactivity disorder as add-on treatment to stimulants: feasibility study and protocol description.

    Science.gov (United States)

    Rosa, Virginia de Oliveira; Schmitz, Marcelo; Moreira-Maia, Carlos Roberto; Wagner, Flavia; Londero, Igor; Bassotto, Caroline de Fraga; Moritz, Guilherme; de Souza, Caroline Dos Santos; Rohde, Luis Augusto Paim

    2017-01-01

    Cognitive training has received increasing attention as a non-pharmacological approach for the treatment of attention deficit/hyperactivity disorder (ADHD) in children and adolescents. Few studies have assessed cognitive training as add-on treatment to medication in randomized placebo controlled trials. The purpose of this preliminary study was to explore the feasibility of implementing a computerized cognitive training program for ADHD in our environment, describe its main characteristics and potential efficacy in a small pilot study. Six ADHD patients aged 10-12-years old receiving stimulants and presenting residual symptoms were enrolled in a randomized clinical trial to either a standard cognitive training program or a controlled placebo condition for 12 weeks. The primary outcome was core ADHD symptoms measured using the Swanson, Nolan and Pelham Questionnaire (SNAP-IV scale). We faced higher resistance than expected to patient enrollment due to logistic issues to attend face-to-face sessions in the hospital and to fill the requirement of medication status and absence of some comorbidities. Both groups showed decrease in parent reported ADHD symptoms without statistical difference between them. In addition, improvements on neuropsychological tests were observed in both groups - mainly on trained tasks. This protocol revealed the need for new strategies to better assess the effectiveness of cognitive training such as the need to implement the intervention in a school environment to have an assessment with more external validity. Given the small sample size of this pilot study, definitive conclusions on the effects of cognitive training as add-on treatment to stimulants would be premature.

  5. Computerized tomography in atypical Pott's disease

    International Nuclear Information System (INIS)

    Cabrera, M.N.B.; Wang, E.H.M.

    1993-01-01

    Classical Pott's disease is described as a two-vertebrae disease with the destruction of the intervening invertebral disc. Computerized tomography has been used in the differential diagnosis of spine infections and neoplasms. We reviewed CT scans of patients seen at the Philippine General Hospital over a two-year period with atypical presentations of atypical tuberculous spondylitis. We used the computerized tomography findings described as characteristic of classical Pott's disease as criteria in evaluating the CT scans of patients diagnosed to have Atypical Pott's Disease. Although the number of patients prevented sensitivity and specificity studies to be done, our results strongly suggest that the same CT criteria used to diagnose Classical Pott's Disease may also be used to diagnose Pott's disease in its atypical form. (Author.). 13 refs

  6. A study on Requirements of Data Base Translator for APR1400 Computerized Procedure System at Shin-Hanul unit 1 and 2

    International Nuclear Information System (INIS)

    Seong, Nokyu; Lee, Sungjin

    2015-01-01

    The CPS is one of the Man Machine Interface (MMI) resources and the CPS can directly display plant graphic objects which are in the Digital Control System (DCS). And the CPS can send a request to DCS to provide DCS screen which is called step support display through DCS link button on a computerized procedure. The procedure writers can insert DCS graphic information to computerized procedure through data base which is provided by CPS Editing System (CPSES). The data base which is provided by CPSES conforms to the naming rule of DCS graphic objects. The naming rule of DCS graphic objects is defined by vendor thus status of DCS graphic objects which are in computerized procedure at Shin-Kori plant cannot be displayed on CPS at Shin-Hanul plant. To use computerized procedure which is written by other plant procedure writer, DCS graphic objects shall be translated by its plant data base. This paper introduces requirements of data base translator to reduce translation and re-inserting graphic objects burden. This paper introduces the requirements of data base translator of CPSES for APR1400 CPS at Shin-Hanul unit 1 and 2. The translator algorithms shall be tested to update data base of CPSES effectively. The prototype of translator is implemented and is being tested using real plant DB. This translator can be applied to Shin- Hanul unit1 and 2 through software V and V

  7. A study on Requirements of Data Base Translator for APR1400 Computerized Procedure System at Shin-Hanul unit 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Nokyu; Lee, Sungjin [KHNP, Daejeon (Korea, Republic of)

    2015-05-15

    The CPS is one of the Man Machine Interface (MMI) resources and the CPS can directly display plant graphic objects which are in the Digital Control System (DCS). And the CPS can send a request to DCS to provide DCS screen which is called step support display through DCS link button on a computerized procedure. The procedure writers can insert DCS graphic information to computerized procedure through data base which is provided by CPS Editing System (CPSES). The data base which is provided by CPSES conforms to the naming rule of DCS graphic objects. The naming rule of DCS graphic objects is defined by vendor thus status of DCS graphic objects which are in computerized procedure at Shin-Kori plant cannot be displayed on CPS at Shin-Hanul plant. To use computerized procedure which is written by other plant procedure writer, DCS graphic objects shall be translated by its plant data base. This paper introduces requirements of data base translator to reduce translation and re-inserting graphic objects burden. This paper introduces the requirements of data base translator of CPSES for APR1400 CPS at Shin-Hanul unit 1 and 2. The translator algorithms shall be tested to update data base of CPSES effectively. The prototype of translator is implemented and is being tested using real plant DB. This translator can be applied to Shin- Hanul unit1 and 2 through software V and V.

  8. Project, building and utilization of a tomograph of micro metric resolution to application in soil science

    International Nuclear Information System (INIS)

    Macedo, Alvaro; Torre Neto, Andre; Cruvinel, Paulo Estevao; Crestana, Silvio

    1996-08-01

    This paper describes the project , building and utilization of a tomograph of micro metric resolution in soil science. It describes the problems involved in soil's science study and it describes the system and methodology

  9. Use of a Computerized Tracking System to Monitor and Provide Feedback on Dietary Goals for Calorie-Restricted Diets: The POUNDS LOST Study

    Science.gov (United States)

    Anton, Stephen D.; LeBlanc, Eric; Allen, H. Raymond; Karabetian, Christy; Sacks, Frank; Bray, George; Williamson, Donald A.

    2012-01-01

    The use of self-monitoring as a tool to facilitate behavioral modification is common in many lifestyle-based weight loss interventions. Electronic tracking programs, including computer-based systems and smart phone applications, have been developed to allow individuals to self-monitor their behavior digitally. These programs offer an advantage over traditional self-report modalities in that they can provide users with direct feedback about dietary and/or physical activity adherence levels and thereby assist them in real-time decision making. This article describes the use of an Internet-based computerized tracking system (CTS) that was developed specifically for the POUNDS LOST study, a 2-year randomized controlled trial designed to test the efficacy of four macronutrient diets for weight and fat reduction in healthy, overweight men and women (body mass index range = 25.0–39.9 kg/m2). The CTS served many functions in this study, including data collection, dietary and exercise assessment and feedback, messaging system, and report generation. Across all groups, participants with high usage of the CTS during the initial 8 weeks lost greater amounts of weight than participants with low usage (8.7% versus 5.5% of initial body weight, respectively; p < .001) at week 32. Rates of CTS utilization were highest during the first year of this 2-year intervention, and utilization of the CTS declined steadily over time. The unique features of the CTS combined with technological developments, such as smart phone applications, offer significant potential to improve the user’s self-monitoring experience and adherence to health promotion programs designed specifically for individuals with obesity and type 2 diabetes. PMID:23063049

  10. Implementing an evidence-based computerized decision support system to improve patient care in a general hospital: the CODES study protocol for a randomized controlled trial.

    Science.gov (United States)

    Moja, Lorenzo; Polo Friz, Hernan; Capobussi, Matteo; Kwag, Koren; Banzi, Rita; Ruggiero, Francesca; González-Lorenzo, Marien; Liberati, Elisa Giulia; Mangia, Massimo; Nyberg, Peter; Kunnamo, Ilkka; Cimminiello, Claudio; Vighi, Giuseppe; Grimshaw, Jeremy; Bonovas, Stefanos

    2016-07-07

    Computerized decision support systems (CDSSs) are information technology-based software that provide health professionals with actionable, patient-specific recommendations or guidelines for disease diagnosis, treatment, and management at the point-of-care. These messages are intelligently filtered to enhance the health and clinical care of patients. CDSSs may be integrated with patient electronic health records (EHRs) and evidence-based knowledge. We designed a pragmatic randomized controlled trial to evaluate the effectiveness of patient-specific, evidence-based reminders generated at the point-of-care by a multi-specialty decision support system on clinical practice and the quality of care. We will include all the patients admitted to the internal medicine department of one large general hospital. The primary outcome is the rate at which medical problems, which are detected by the decision support software and reported through the reminders, are resolved (i.e., resolution rates). Secondary outcomes are resolution rates for reminders specific to venous thromboembolism (VTE) prevention, in-hospital all causes and VTE-related mortality, and the length of hospital stay during the study period. The adoption of CDSSs is likely to increase across healthcare systems due to growing concerns about the quality of medical care and discrepancy between real and ideal practice, continuous demands for a meaningful use of health information technology, and the increasing use of and familiarity with advanced technology among new generations of physicians. The results of our study will contribute to the current understanding of the effectiveness of CDSSs in primary care and hospital settings, thereby informing future research and healthcare policy questions related to the feasibility and value of CDSS use in healthcare systems. This trial is seconded by a specialty trial randomizing patients in an oncology setting (ONCO-CODES). ClinicalTrials.gov, https://clinicaltrials.gov/ct2

  11. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer

    2004-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  12. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer S

    2005-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  13. Computed tomographic findings of intracranial gliosis

    International Nuclear Information System (INIS)

    Weisberg, L.

    1981-01-01

    The clinical and computed tomographic (CT) findings in eight patients with pathological evidence of cerebral gliosis are analyzed. CT findings do not permit differentiation of gliosis from other neoplastic and non-neoplastic conditions. (orig.)

  14. A Study of the Efficacy of Computerized Skill Building for Adolescents: Reducing Aggression and Increasing Pro-Social Behavior.

    Science.gov (United States)

    Stern, Robin; Repa, J. Theodore

    This article describes a pilot study that evaluated the efficacy of a computer-based, behavioral skill-building program in reducing aggression and improving academic performance among middle school students. The program is Ripple Effects'"Relate for Teens," a media rich, interactive application based on combining a proprietary learning…

  15. Precision tomographic analysis of reactor fuels

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Deok; Lee, Chang Hee; Kim, Jong Soo; Jeong, Jwong Hwan; Nam, Ki Yong

    2001-03-01

    For the tomographical assay, search of current status, analysis of neutron beam characteristics, MCNP code simulation, sim-fuel fabrication, neutron experiment for sim-fuel, multiaxes operation system design were done. In sensitivity simulation, the reconstruction results showed the good agreement. Also, the scoping test at ANL was very helpful for actual assay. Therefore, the results are applied for HANARO tomographical system setup and consecutive next research.

  16. Precision tomographic analysis of reactor fuels

    International Nuclear Information System (INIS)

    Lee, Yong Deok; Lee, Chang Hee; Kim, Jong Soo; Jeong, Jwong Hwan; Nam, Ki Yong

    2001-03-01

    For the tomographical assay, search of current status, analysis of neutron beam characteristics, MCNP code simulation, sim-fuel fabrication, neutron experiment for sim-fuel, multiaxes operation system design were done. In sensitivity simulation, the reconstruction results showed the good agreement. Also, the scoping test at ANL was very helpful for actual assay. Therefore, the results are applied for HANARO tomographical system setup and consecutive next research

  17. Stratification of mammographic computerized analysis by BI-RADS categories

    Energy Technology Data Exchange (ETDEWEB)

    Lederman, Richard [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Leichter, Isaac [Department of Electro-Optics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem (Israel); Buchbinder, Shalom [Department of Radiology of The Montefiore Medical Center, The University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States); Novak, Boris [Department of Applied Mathematics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem 91160 (Israel); Bamberger, Philippe [Department of Electronics, Jerusalem College of Technology, POB 16031, Jerusalem (Israel); Fields, Scott [Department of Radiology, Hadassah University Hospital, Mt. Scopus, Jerusalem (Israel)

    2003-02-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A{sub z}of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A {sub z}of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A {sub z}significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  18. Stratification of mammographic computerized analysis by BI-RADS categories

    International Nuclear Information System (INIS)

    Lederman, Richard; Leichter, Isaac; Buchbinder, Shalom; Novak, Boris; Bamberger, Philippe; Fields, Scott

    2003-01-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A z of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A z of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A z significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  19. 3-Dimensional Physiologic Postural Range of the Mandible: A Computerized-Assisted Technique—A Case Study

    Directory of Open Access Journals (Sweden)

    Todd Shewman

    2013-01-01

    Full Text Available Previous studies demonstrated that while the mandible assumes its resting position in space, antagonistic muscles should assume minimal muscle activity within a spatial range. This zone of mandibular rest has been mapped using physiologic parameters of muscle activity and incisal spatial kinematics. This case study expands on previous research by monitoring incisal and posterior jaw position and includes lateral pterygoid muscle activity, thus allowing for determining the spatial range including additional relevant coordinates and muscle activity. Four positions were evaluated: a maximum physiologic open position, a maximum physiologic closed position, physiologic rest position, and maximum physiologic protrusion position. Within the physiologic zone of rest formed by these 4 positions, the vertical and anterior borders of the envelope of function may be documented for the incisal and posterior mandible in true 3-dimensional fashion to assist the clinician in determining a physiologic interocclusal freeway space and vertical dimension of occlusion. Advantages and limitations are discussed.

  20. Cognitive impairment and its relation to imaging measures in multiple sclerosis: a study using a computerized battery.

    Science.gov (United States)

    Pellicano, Clelia; Kane, Robert L; Gallo, Antonio; Xiaobai, Li; Stern, Susan K; Ikonomidou, Vasiliki N; Evangelou, Iordanis E; Ohayon, Joan M; Ehrmantraut, Mary; Cantor, Fredric K; Bagnato, Francesca

    2013-07-01

    Cognitive impairment (CI) is an important component of multiple sclerosis (MS) disability. A complex biological interplay between white matter (WM) and gray matter (GM) disease likely sustains CI. This study aims to address this issue by exploring the association between the extent of normal WM and GM disease and CI. Cognitive function of 24 MS patients and 24 healthy volunteers (HVs) was studied using the Automated Neuropsychological Assessment Metrics (ANAM) battery. WM focal lesions and normal appearing WM (NAWM) volume in patients, cortical thickness (CTh) and deep GM structure volumes in both patients and HVs were measured by high field strength (3.0-Tesla; 3T) imaging. An analysis of covariance showed that patients performed worse than HVs on Code Substitution Delayed Memory (P = .04) and Procedural Reaction Time (P = .05) indicative of reduced performance in memory, cognitive flexibility, and processing speed. A summary score (Index of Cognitive Efficiency) indicating global test battery performance was also lower for the patient group (P = .04). Significant associations, as determined by the Spearman rank correlation tests, were noted between each of these 3 cognitive scores and measures of NAWM volume [CDD-TP1(r = .609; P = .0035), PRO-TP1 (r = .456; P = .029) and ICE (r = .489; P = .0129)], CTh (r = .5; P ≤ .05) and volume of subcortical normal appearing GM (NAGM) structures (r = .4; P≤ .04), but not WM lesions. Both NAWM and NAGM volumes are related to CI in MS. The results highlight once again the urgent need to develop pharmacological strategies protecting patients from widespread neurodegeneration as possible preventive strategies of CI development. Copyright © 2012 by the American Society of Neuroimaging.

  1. Daily stress, presleep arousal, and sleep in healthy young women: a daily life computerized sleep diary and actigraphy study.

    Science.gov (United States)

    Winzeler, Katja; Voellmin, Annette; Schäfer, Valérie; Meyer, Andrea H; Cajochen, Christian; Wilhelm, Frank H; Bader, Klaus

    2014-03-01

    Our study aimed to further elucidate the mediating role of presleep arousal in the relationship between daily stress and sleep by investigating subjective sleep quality and actigraphy-assessed sleep efficiency (SE) on both within- and between-participant levels in a sample of healthy young women. Multilevel modeling was applied on electronically assessed data comprising 14 consecutive nights in 145 healthy young women to assess the relationship between daily stress, presleep (somatic and cognitive) arousal, and sleep on both levels between participants and within participants across days. Higher levels of daily stress were consistently and significantly associated with higher levels of somatic and cognitive arousal. Somatic arousal mediated the relationship between daily stress and worsened subjective sleep quality on the between-participant level, while cognitive arousal mediated the relationship between daily stress and worsened subjective sleep quality on the within-participants level. Unexpectedly, healthy young women showed higher SE following days with above-average stress with somatic arousal mediating this relationship. Our data corroborate the role of presleep arousal mediating the relationship between daily stress and subjective sleep quality. Interestingly this effect was restricted to somatic arousal being relevant on interindividual levels and cognitive arousal on intraindividual levels. For young and healthy individuals who experience high stress and arousal, well-established cognitive-behavioral techniques could be useful to regulate arousal and prevent worse subjective sleep quality. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Technologies in computerized lexicography | Kruyt | Lexikos

    African Journals Online (AJOL)

    Although the topic of this paper is technology, focus is on functional rather than technical aspects of computerized lexicography. Keywords: computerized lexicography, electronic dictionary, electronic text corpus, lexicographer's workbench, integrated language database, automatic linguistic analysis, information retrieval, ...

  3. Tomographic PIV: particles versus blobs

    International Nuclear Information System (INIS)

    Champagnat, Frédéric; Cornic, Philippe; Besnerais, Guy Le; Plyer, Aurélien; Cheminet, Adam; Leclaire, Benjamin

    2014-01-01

    We present an alternative approach to tomographic particle image velocimetry (tomo-PIV) that seeks to recover nearly single voxel particles rather than blobs of extended size. The baseline of our approach is a particle-based representation of image data. An appropriate discretization of this representation yields an original linear forward model with a weight matrix built with specific samples of the system’s point spread function (PSF). Such an approach requires only a few voxels to explain the image appearance, therefore it favors much more sparsely reconstructed volumes than classic tomo-PIV. The proposed forward model is general and flexible and can be embedded in a classical multiplicative algebraic reconstruction technique (MART) or a simultaneous multiplicative algebraic reconstruction technique (SMART) inversion procedure. We show, using synthetic PIV images and by way of a large exploration of the generating conditions and a variety of performance metrics, that the model leads to better results than the classical tomo-PIV approach, in particular in the case of seeding densities greater than 0.06 particles per pixel and of PSFs characterized by a standard deviation larger than 0.8 pixels. (paper)

  4. Visual servoing in medical robotics: a survey. Part II: tomographic imaging modalities--techniques and applications.

    Science.gov (United States)

    Azizian, Mahdi; Najmaei, Nima; Khoshnam, Mahta; Patel, Rajni

    2015-03-01

    Intraoperative application of tomographic imaging techniques provides a means of visual servoing for objects beneath the surface of organs. The focus of this survey is on therapeutic and diagnostic medical applications where tomographic imaging is used in visual servoing. To this end, a comprehensive search of the electronic databases was completed for the period 2000-2013. Existing techniques and products are categorized and studied, based on the imaging modality and their medical applications. This part complements Part I of the survey, which covers visual servoing techniques using endoscopic imaging and direct vision. The main challenges in using visual servoing based on tomographic images have been identified. 'Supervised automation of medical robotics' is found to be a major trend in this field and ultrasound is the most commonly used tomographic modality for visual servoing. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Tomographic findings of acute pulmonary toxoplasmosis in immunocompetent patients.

    Science.gov (United States)

    de Souza Giassi, Karina; Costa, Andre Nathan; Apanavicius, Andre; Teixeira, Fernando Bin; Fernandes, Caio Julio Cesar; Helito, Alfredo Salim; Kairalla, Ronaldo Adib

    2014-11-25

    Toxoplasmosis is one of the most common human zoonosis, and is generally benign in most of the individuals. Pulmonary involvement is common in immunocompromised subjects, but very rare in immunocompetents and there are scarce reports of tomographic findings in the literature. The aim of the study is to describe three immunocompetent patients diagnosed with acute pulmonary toxoplasmosis and their respective thoracic tomographic findings. Acute toxoplasmosis was diagnosed according to the results of serological tests suggestive of recent primary infection and the absence of an alternative etiology. From 2009 to 2013, three patients were diagnosed with acute respiratory failure secondary to acute toxoplasmosis. The patients were two female and one male, and were 38, 56 and 36 years old. Similarly they presented a two-week febrile illness and progressive dyspnea before admission. Laboratory tests demonstrated lymphocytosis, slight changes in liver enzymes and high inflammatory markers. Tomographic findings were bilateral smooth septal and peribronchovascular thickening (100%), ground-glass opacities (100%), atelectasis (33%), random nodules (33%), lymph node enlargement (33%) and pleural effusion (66%). All the patients improved their symptoms after treatment, and complete resolution of tomographic findings were found in the followup. These cases provide a unique description of the presentation and evolution of pulmonary tomographic manifestations of toxoplasmosis in immunocompetent patients. Toxoplasma pneumonia manifests with fever, dyspnea and a non-productive cough that may result in respiratory failure. In animal models, changes were described as interstitial pneumonitis with focal infiltrates of neutrophils that can finally evolve into a pattern of diffuse alveolar damage with focal necrosis. The tomographic findings are characterized as ground glass opacities, smooth septal and marked peribronchovascular thickening; and may mimic pulmonary congestion

  6. Coronary Computed Tomographic Angiography at Low Concentration of Contrast Agent and Low Tube Voltage in Patients with Obesity:: A Feasibility Study.

    Science.gov (United States)

    Pan, Yu-Ning; Li, Ai-Jing; Chen, Xiao-Min; Wang, Jian; Ren, Da-Wei; Huang, Qiu-Li

    2016-04-01

    Using lower tube voltage can reduce the exposure to radiation and the dose of contrast agent. However, lower tube voltage is often linked to more noise and poor image quality, which create a need for more effective technology to resolve this problem. To explore the feasibility of coronary computed tomographic angiography (CCTA) in patients with obesity at low tube voltage (100 kV) and low contrast agent concentration (270 mg/mL) using iterative reconstruction. A total of 48 patients with body mass index greater than 30 kg/m(2) were included and randomly divided into two groups. Group A received a traditional protocol (iopromide 370 mg/mL + 120 kV); group B received a protocol with low tube voltage (100 kV), low contrast agent concentration (270 mg/mL), and iterative reconstruction. The effective dose (ED), average attenuation values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), the figure of merit (FOM), image quality scores, and the total iodine intake were compared. No significant differences in average CT attenuations, SNR, CNR, and subjective scores were noticed between the two groups (P > 0.05), whereas the FOM of group B was significantly higher than that of group A. Effective radiation dose, total iodine, and iodine injection rate in group B were lower than those of group A (P contrast agent with low iodine concentration and low-dose CCTA were feasible. Substantial reduction in radiation dose and the iodine intake could be achieved without compromising the image quality. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  7. Computed tomographic diagnosis of abdominal abscess in childhood

    International Nuclear Information System (INIS)

    Kuhn, J.P.; Berger, P.E.

    1980-01-01

    Twenty-eight children suspected clinically of having an abdominal abscess were examined by CT. Eighteen had gallium 67 citrate scans and 22 had ultrasound studies. Computed tomography was found to be the most accurate test for diagnosis and evaluation of an abscess and the computed tomographic appearance of abscess is illustrated. However, because of cost factors, radiation dose, and clinical considerations, computed tomography is not always the first modality of choice in evaluating a suspected abdominal abscess [fr

  8. A general purpose tomographic program with combined inversions

    International Nuclear Information System (INIS)

    Xu Wenbin; Dong Jiafu; Li Fanzhu

    1996-01-01

    A general tomographic program has been developed by combining the Bessel expansion with the Zernicke expansion. It is useful for studying of the magnetic island structure of the tearing mode and in reconstructing the density profiles of impurities in tokamak plasmas. This combined method have the advantages of both expansions, i.e. there will be no spurious images in the edge and it will be of high inverse precision in the center of plasma

  9. Computer tomographic evaluation of digestive tract non-Hodgkin lymphomas.

    Science.gov (United States)

    Lupescu, Ioana G; Grasu, Mugur; Goldis, Gheorghe; Popa, Gelu; Gheorghe, Cristian; Vasilescu, Catalin; Moicean, Andreea; Herlea, Vlad; Georgescu, Serban A

    2007-09-01

    Computer Tomographic (CT) study is crucial for defining distribution, characteristics and staging of primary gastrointestinal lymphomas. The presence of multifocal sites, the wall thickening with diffuse infiltration of the affected gastrointestinal (GI) segment in association with regional adenopathies, permit the orientation of the CT diagnosis for primary GI lymphomas. The gold standard for diagnosis remains, in all cases of digestive tract non-Hodgkin lymphomas (NHL), the histological examination, which allows a tissue diagnosis, performed preferably by transmural biopsy.

  10. Computerized Proof Techniques for Undergraduates

    Science.gov (United States)

    Smith, Christopher J.; Tefera, Akalu; Zeleke, Aklilu

    2012-01-01

    The use of computer algebra systems such as Maple and Mathematica is becoming increasingly important and widespread in mathematics learning, teaching and research. In this article, we present computerized proof techniques of Gosper, Wilf-Zeilberger and Zeilberger that can be used for enhancing the teaching and learning of topics in discrete…

  11. Dose profile study on computerized tomography scanning of skull with simulator object; Estudo do perfil de dose em varreduras de TC de cranio com objeto simulador

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, A.P., E-mail: aprata@des.cefetmg.b [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET/MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar; Alonso, Thessa C.; Silva, Teogenes A. da, E-mail: alonso@cdtn.b, E-mail: silvata@@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-10-26

    This work presents a comparison among the dose profiles in scanning of computerized tomography of a simulator object of PMMA in its periphery region. To obtain the deposited dose at the PMMA thermoluminescent dosemeters were used positioned at the interior of PMMA simulated object longitudinal to periphery and at the center of cylinder (positions denominated North, South, East, West and Center). Eight scanning were performed of simulator object using the routine protocol for skull in eight different services of radiodiagnostic by TC

  12. Computerized adaptive testing in computer assisted learning?

    NARCIS (Netherlands)

    Veldkamp, Bernard P.; Matteucci, Mariagiulia; Eggen, Theodorus Johannes Hendrikus Maria; De Wannemacker, Stefan; Clarebout, Geraldine; De Causmaecker, Patrick

    2011-01-01

    A major goal in computerized learning systems is to optimize learning, while in computerized adaptive tests (CAT) efficient measurement of the proficiency of students is the main focus. There seems to be a common interest to integrate computerized adaptive item selection in learning systems and

  13. Roentgen and X-ray computerized tomographic (CT) imaging of cysts in the maxilla

    International Nuclear Information System (INIS)

    Rahmatulla, M

    1999-01-01

    Two cysts in the maxilla were subjected to routine roentgen imaging followed by CT scanning. Roentgen investigation included periapical, occlusal, and panoramic views. CT imaging included axial and coronal scans. While roentgen views were adequate in establishing the diagnosis of the cystic lesions, CT scan was useful in understanding the precise antero-posterior expansion and depth of the lesion. Interpretation of CT scan of cystic jaw lesions without con-ventional radiographs can be misleading. Hence, the CT procedure may be used only as supplement to the routine radiographic investigations particularly in cystic lesions of the jaws. (author)

  14. From tomographic images to fault heterogeneities

    Directory of Open Access Journals (Sweden)

    A. Amato

    1994-06-01

    Full Text Available Local Earthquake Tomography (LET is a useful tool for imaging lateral heterogeneities in the upper crust. The pattern of P- and S-wave velocity anomalies, in relation to the seismicity distribution along active fault zones. can shed light on the existence of discrete seismogenic patches. Recent tomographic studies in well monitored seismic areas have shown that the regions with large seismic moment release generally correspond to high velocity zones (HVZ's. In this paper, we discuss the relationship between the seismogenic behavior of faults and the velocity structure of fault zones as inferred from seismic tomography. First, we review some recent tomographic studies in active strike-slip faults. We show examples from different segments of the San Andreas fault system (Parkfield, Loma Prieta, where detailed studies have been carried out in recent years. We also show two applications of LET to thrust faults (Coalinga, Friuli. Then, we focus on the Irpinia normal fault zone (South-Central Italy, where a Ms = 6.9 earthquake occurred in 1980 and many thousands of attershock travel time data are available. We find that earthquake hypocenters concentrate in HVZ's, whereas low velocity zones (LVZ’ s appear to be relatively aseismic. The main HVZ's along which the mainshock rupture bas propagated may correspond to velocity weakening fault regions, whereas the LVZ's are probably related to weak materials undergoing stable slip (velocity strengthening. A correlation exists between this HVZ and the area with larger coseismic slip along the fault, according to both surface evidence (a fault scarp as high as 1 m and strong ground motion waveform modeling. Smaller wave-length, low-velocity anomalies detected along the fault may be the expression of velocity strengthening sections, where aseismic slip occurs. According to our results, the rupture at the nucleation depth (~ 10-12 km is continuous for the whole fault lenoth (~ 30 km, whereas at shallow depth

  15. Emerging tomographic methods within the petroleum industry

    International Nuclear Information System (INIS)

    Johansen, Geir Anton

    2013-01-01

    Since industrial process tomography was introduced as a concept almost two decades ago, the considerable progress within a large variety of sensing modalities has to a large extent been technology driven. Industrial tomography applications may be divided into three categories: 1) Laboratory systems, 2) Field equipment for diagnostics and mapping purposes, and 3) Permanently installed systems. Examples on emerging methods on all categories will be presented, either from R and D at the University of Bergen and/or our industrial partners. Most developments are within the first category, where tomographs are used to provide better understanding of various processes such as pipe flow, separators, mixers and reactors. Here tomographic data is most often used to provide better process knowledge, for reference measurements and validation and development of process models, and finally for development for instruments and process equipment. The requirement here may be either high spatial resolution or high temporal resolution, or combinations of these. Tomographic field measurements are applied to either to inspect processes or equipment on a regular base or at faulty or irregular operation, or to map multicomponent systems such petroleum reservoirs, their structure and the distribution gas, oil and water within them. The latter will only be briefly touched upon here. Tomographic methods are increasingly being used for process and equipment diagnostics. The requirements vary and solutions based on repetition of single measurements, such as in column scanning, to full tomographic systems where there is sufficiently space or access. The third category is tomographic instruments that are permanently installed in situ in a process. These need not provide full tomographic images and instruments with fewer views are often preferred to reduce complexity and increase the instrument reliability. (author)

  16. Tomographic Particle Image Velocimetry Using Colored Shadow Imaging

    KAUST Repository

    Alarfaj, Meshal K.

    2016-02-01

    Tomographic Particle Image Velocimetry Using Colored Shadow Imaging by Meshal K Alarfaj, Master of Science King Abdullah University of Science & Technology, 2015 Tomographic Particle image velocimetry (PIV) is a recent PIV method capable of reconstructing the full 3D velocity field of complex flows, within a 3-D volume. For nearly the last decade, it has become the most powerful tool for study of turbulent velocity fields and promises great advancements in the study of fluid mechanics. Among the early published studies, a good number of researches have suggested enhancements and optimizations of different aspects of this technique to improve the effectiveness. One major aspect, which is the core of the present work, is related to reducing the cost of the Tomographic PIV setup. In this thesis, we attempt to reduce this cost by using an experimental setup exploiting 4 commercial digital still cameras in combination with low-cost Light emitting diodes (LEDs). We use two different colors to distinguish the two light pulses. By using colored shadows with red and green LEDs, we can identify the particle locations within the measurement volume, at the two different times, thereby allowing calculation of the velocities. The present work tests this technique on the flows patterns of a jet ejected from a tube in a water tank. Results from the images processing are presented and challenges discussed.

  17. An introduction to the tomographic picture of quantum mechanics

    International Nuclear Information System (INIS)

    Ibort, A; Man'ko, V I; Marmo, G; Simoni, A; Ventriglia, F

    2009-01-01

    Starting from the famous Pauli problem on the possibility of associating quantum states with probabilities, the formulation of quantum mechanics in which quantum states are described by fair probability distributions (tomograms, i.e. tomographic probabilities) is reviewed in a pedagogical style. The relation between the quantum state description and the classical state description is elucidated. The difference between those sets of tomograms is described by inequalities equivalent to a complete set of uncertainty relations for the quantum domain and to non-negativity of probability density on phase space in the classical domain. The intersection of such sets is studied. The mathematical mechanism that allows us to construct different kinds of tomographic probabilities like symplectic tomograms, spin tomograms, photon number tomograms, etc is clarified and a connection with abstract Hilbert space properties is established. The superposition rule and uncertainty relations in terms of probabilities as well as quantum basic equations like quantum evolution and energy spectra equations are given in an explicit form. A method to check experimentally the uncertainty relations is suggested using optical tomograms. Entanglement phenomena and the connection with semigroups acting on simplexes are studied in detail for spin states in the case of two-qubits. The star-product formalism is associated with the tomographic probability formulation of quantum mechanics.

  18. Tomographic findings of lobar consolidation in primary pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Pereira, Bruno Alberto Falcao; Macedo, Solange Goncalves David de; Penna, Claudia Renata Rezende

    2009-01-01

    Objective: To describe tomographic findings of lobar consolidation as early manifestation of primary pulmonary tuberculosis. Materials and methods: The present study was developed at Hospital Municipal Jesus, Rio de Janeiro, RJ, Brazil, in the period between 2002 and 2006, retrospectively evaluating tomographic findings in four children aged from 3 to 14 months with lobar consolidation as an early manifestation of primary pulmonary tuberculosis. Results: The most frequently found radiological pattern was lobar consolidation with calcifications, cavitation and intermingle necrotic areas, associated with bulging fissure. Signs of bronchogenic dissemination and lymph node enlargement were observed in all of the four children. Consolidation with a pseudotumor aspect and masslike effect was observed in one case. Conclusion: The cases included in the present study have demonstrated that primary pulmonary tuberculosis manifested as lobar consolidation presents typical tomographic images such as cavitation, hypodense areas and calcifications intermingled with consolidation. The association with lymph node enlargement with central necrosis and signs of bronchogenic dissemination reinforce the diagnosis of tuberculosis. (author)

  19. Positioning of Nuclear Fuel Assemblies by Means of Image Analysis on Tomographic Data

    International Nuclear Information System (INIS)

    Troeng, Mats

    2005-06-01

    A tomographic measurement technique for nuclear fuel assemblies has been developed at the Department of Radiation Sciences at Uppsala University. The technique requires highly accurate information about the position of the measured nuclear fuel assembly relative to the measurement equipment. In experimental campaigns performed earlier, separate positioning measurements have therefore been performed in connection to the tomographic measurements. In this work, another positioning approach has been investigated, which requires only the collection of tomographic data. Here, a simplified tomographic reconstruction is performed, whereby an image is obtained. By performing image analysis on this image, the lateral and angular position of the fuel assembly can be determined. The position information can then be used to perform a more accurate tomographic reconstruction involving detailed physical modeling. Two image analysis techniques have been developed in this work. The stability of the two techniques with respect to some central parameters has been studied. The agreement between these image analysis techniques and the previously used positioning technique was found to meet the desired requirements. Furthermore, it has been shown that the image analysis techniques offer more detailed information than the previous technique. In addition, its off-line analysis properties reduce the need for valuable measurement time. When utilizing the positions obtained from the image analysis techniques in tomographic reconstructions of the rod-by-rod power distribution, the repeatability of the reconstructed values was improved. Furthermore, the reconstructions resulted in better agreement to theoretical data

  20. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  1. Computerized photogrammetry used to calculate the brow position index.

    Science.gov (United States)

    Naif-de-Andrade, Naif Thadeu; Hochman, Bernardo; Naif-de-Andrade, Camila Zirlis; Ferreira, Lydia Masako

    2012-10-01

    The orbital region is of vital importance to facial expression. Brow ptosis, besides having an impact on facial harmony, is a sign of aging. Various surgical techniques have been developed to increase the efficacy of brow-lift surgery. However, no consensus method exists for an objective measurement of the eyebrow position due to the curvature of the face. Therefore, this study aimed to establish a method for measuring the eyebrow position using computerized photogrammetry. For this study, 20 orbital regions of 10 volunteers were measured by direct anthropometry using a digital caliper and by indirect anthropometry (computerized photogrammetry) using standardized digital photographs. Lines, points, and distances were defined based on the position of the anthropometric landmarks endocanthion and exocanthion and then used to calculate the brow position index (BPI). Statistical analysis was performed using Student's t test with a significance level of 5 %. The BPI values obtained by computerized photogrammetric measurements did not differ significantly from those obtained by direct anthropometric measurements (p > 0.05). The mean BPI was 84.89 ± 10.30 for the computerized photogrammetric measurements and 85.27 ± 10.67 for the direct anthropometric measurements. The BPI defined in this study and obtained by computerized photogrammetry is a reproducible and efficient method for measuring the eyebrow position. This journal requires that authors assign a level of evidence to each article.

  2. Introduction to curved rotary tomographic apparatus 'TOMOREX'

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Shinojima, Masayasu; Kohirasawa, Hideo; Tokui, Mitsuru

    1980-01-01

    In recent years, panorama X-ray photographic method is widely used for the X-ray diagnosis of teeth, jawbones and faces. One type based on the principle of tomography is curved surface rotary tomographic method utilizing fine-gap X-ray beam. With the synchronous rotation of an X-ray tube and a photographic film around a face, describing a U-shaped tomographic plane along a dental arch, an upper or lower jawbone is photographed. In the ''TOMOREX'' belonging to this type, is different tomographic planes are available, so that by selecting any position in advance, the part can be photographed. Furthermore, patients can be subjected to examination as laid on a stretcher. The mechanism and equipment, and the photographic method for eye sockets, cheekbones, upper jaw cavities and stereoscopic images are described. (J.P.N.)

  3. Computed tomographic findings of intracranial pyogenic abscess

    International Nuclear Information System (INIS)

    Kim, S. J.; Suh, J. H.; Park, C. Y.; Lee, K. C.; Chung, S. S.

    1982-01-01

    The early diagnosis and effective treatment of brain abscess pose a difficult clinical problem. With the advent of computed tomography, however, it appears that mortality due to intracranial abscess has significantly diminished. 54 cases of intracranial pyogenic abscess are presented. Etiologic factors and computed tomographic findings are analyzed and following result are obtained. 1. The common etiologic factors are otitis media, post operation, and head trauma, in order of frequency. 2. The most common initial computed tomographic findings of brain abscess is ring contrast enhancement with surrounding brain edema. 3. The most characteristic computed tomographic finding of ring contrast enhancement is smooth thin walled ring contrast enhancement. 4. Most of thick irregular ring contrast enhancement are abscess associated with cyanotic heart disease or poor operation. 5. The most common findings of epidural and subdural empyema is crescentic radiolucent area with thin wall contrast enhancement without surrounding brain edema in convexity of brain

  4. Computed tomographic findings of intracerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Kyo; Lee, Sun Wha; Kim, Ho Kyun; Ahn, Chi Yul [School of Medicine, Kyung-Hee University, Seoul (Korea, Republic of)

    1980-12-15

    Cysticercosis is a parasitic disease in which man serves as the intermediate host of Taenia Solium, the pork tapeworm. The computed tomographic findings of 25 cases of intracerebral cysticercosis proven by pathologic and/or clinical findings during past 2 years were analysed. The results were as follows; 1. The sex was 19 males and 6 females, and 56 percent of the patients were seen in fourth and fifth decades. The most common symptom was epilepsy (72%). 2. The C. T. findings in precontrast study were varied; such as ill defined low density (48%), cystic low density (20%), dilated ventricles (20%), ill defined low density with isodense nodule (18%), cystic low density with isodense mural nodule (12%) and calcification (8%). 3. The areas of involvement were 20 cases (80%) of parenchymal form, 3 cases (12%) of ventricular form and 2 cases (8%) of mixed form. 4. The contrast-enhanced 13 cases were 5 nodular, 5 ring or rim-like and 3 mixed type enhancements, while 12 cases were not enhanced. 5. C.T. scan demonstrated more precise location and extents of cerebral cysticercosis, especially in parenchymal form. It was considered to be important in determination of surgical feasibility and its approach.

  5. Computerized ECT data analysis system

    International Nuclear Information System (INIS)

    Miyake, Y.; Fukui, S.; Iwahashi, Y.; Matsumoto, M.; Koyama, K.

    1988-01-01

    For the analytical method of the eddy current testing (ECT) of steam generator tubes in nuclear power plants, the authors have developed the computerized ECT data analysis system using a large-scale computer with a high-resolution color graphic display. This system can store acquired ECT data up to 15 steam generators, and ECT data can be analyzed immediately on the monitor in dialogue communication with a computer. Analyzed results of ECT data are stored and registered in the data base. This system enables an analyst to perform sorting and collecting of data under various conditions and obtain the results automatically, and also to make a plan of tube repair works. This system has completed the test run, and has been used for data analysis at the annual inspection of domestic plants. This paper describes an outline, features and examples of the computerized eddy current data analysis system for steam generator tubes in PWR nuclear power plants

  6. Radiation and contrast agent doses reductions by using 80-kV tube voltage in coronary computed tomographic angiography: A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Jian-xin [Department of Radiology, Wuhan 161th Hospital, Wuhan (China); Wang, Yi-min, E-mail: wym6669@yahoo.com.cn [Department of Radiology, Wuhan 161th Hospital, Wuhan (China); Lu, Jin-guo [Department of Cardiology, Asia Heart Hospital, Wuhan (China); Zhang, Yu; Wang, Peng; Yang, Cheng [Department of Radiology, Wuhan 161th Hospital, Wuhan (China)

    2014-02-15

    Objective: To investigate the effects of 80-kilovoltage (kV) tube voltage coronary computed tomographic angiography (CCTA) with a reduced amount of contrast agent on qualitative and quantitative image quality parameters and on radiation dose in patients with a body mass index (BMI) <23.0 kg/m{sup 2}. Methods: One hundred and twenty consecutive patients with a BMI <23.0 kg/m{sup 2} and a low calcium load undergoing retrospective electrocardiogram (ECG)-gated dual-source CCTA were randomized into two groups [standard-tube voltage (120-kV) vs. low-tube voltage (80-kV)]. The injection flow rate of contrast agent (350 mg I/mL) was adjusted to body weight of each patient (4.5–5.5 mL/s in the 120-kV group and 2.8–3.8 mL/s in the 80-kV group). Radiation and contrast agent doses were evaluated. Quantitative image quality parameters and figure of merit (FOM) of coronary artery were evaluated. Each coronary segment was evaluated for image quality on a 4-point scale. Results: Compared with the 120-kV group, effective dose and amount of contrast agent in the 80-kV group were decreased by 57.8% and 30.5% (effective dose:2.7 ± 0.5vs. 6.4 ± 1.3 mSv; amount of contrast agent:57.1 ± 3.2 vs. 82.1 ± 6.1 mL; both p < 0.0001), respectively. Image noise was 22.7 ± 2.1 HU for 120-kV images and 33.2 ± 5.2 HU for 80-kV images (p < 0.0001). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the proximal right coronary artery (RCA) and left main coronary artery (LMA) were all lower in 80-kV than 120-kV images (SNR in the proximal RCA: 16.5 ± 1.8 vs. 19.4 ± 2.8; SNR in the LMA: 16.3 ± 2.0 vs.19.6 ± 2.7; CNR in the proximal RCA: 19.4 ± 2.3 vs.22.9 ± 3.0; CNR in the LMA: 18.8 ± 2.4 vs. 22.7 ± 2.9; all p < 0.0001). FOM were all significantly higher in 80-kV than 120-kV images (proximal RCA: 146.7 ± 45.1 vs. 93.4 ± 32.0; LMA: 139.1 ± 47.2 vs. 91.6 ± 31.1; all p < 0.0001). There was no significant difference in image quality score between the two groups (3.3 ± 0

  7. Radiation and contrast agent doses reductions by using 80-kV tube voltage in coronary computed tomographic angiography: A comparative study

    International Nuclear Information System (INIS)

    Cao, Jian-xin; Wang, Yi-min; Lu, Jin-guo; Zhang, Yu; Wang, Peng; Yang, Cheng

    2014-01-01

    Objective: To investigate the effects of 80-kilovoltage (kV) tube voltage coronary computed tomographic angiography (CCTA) with a reduced amount of contrast agent on qualitative and quantitative image quality parameters and on radiation dose in patients with a body mass index (BMI) <23.0 kg/m 2 . Methods: One hundred and twenty consecutive patients with a BMI <23.0 kg/m 2 and a low calcium load undergoing retrospective electrocardiogram (ECG)-gated dual-source CCTA were randomized into two groups [standard-tube voltage (120-kV) vs. low-tube voltage (80-kV)]. The injection flow rate of contrast agent (350 mg I/mL) was adjusted to body weight of each patient (4.5–5.5 mL/s in the 120-kV group and 2.8–3.8 mL/s in the 80-kV group). Radiation and contrast agent doses were evaluated. Quantitative image quality parameters and figure of merit (FOM) of coronary artery were evaluated. Each coronary segment was evaluated for image quality on a 4-point scale. Results: Compared with the 120-kV group, effective dose and amount of contrast agent in the 80-kV group were decreased by 57.8% and 30.5% (effective dose:2.7 ± 0.5vs. 6.4 ± 1.3 mSv; amount of contrast agent:57.1 ± 3.2 vs. 82.1 ± 6.1 mL; both p < 0.0001), respectively. Image noise was 22.7 ± 2.1 HU for 120-kV images and 33.2 ± 5.2 HU for 80-kV images (p < 0.0001). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the proximal right coronary artery (RCA) and left main coronary artery (LMA) were all lower in 80-kV than 120-kV images (SNR in the proximal RCA: 16.5 ± 1.8 vs. 19.4 ± 2.8; SNR in the LMA: 16.3 ± 2.0 vs.19.6 ± 2.7; CNR in the proximal RCA: 19.4 ± 2.3 vs.22.9 ± 3.0; CNR in the LMA: 18.8 ± 2.4 vs. 22.7 ± 2.9; all p < 0.0001). FOM were all significantly higher in 80-kV than 120-kV images (proximal RCA: 146.7 ± 45.1 vs. 93.4 ± 32.0; LMA: 139.1 ± 47.2 vs. 91.6 ± 31.1; all p < 0.0001). There was no significant difference in image quality score between the two groups (3.3 ± 0.8 vs. 3

  8. Arbitrary layer tomographic method and apparatus

    International Nuclear Information System (INIS)

    Kato, H.; Ishida, M.

    1984-01-01

    Many two-dimensional X-ray projection distribution images obtained by exposing an object to X-rays in various directions are once stored in positions different from one another in a stimulable phosphor sheet or respectively in many stimulable phosphor sheets. The stimulable phosphor sheet or sheets are then scanned with stimulating rays, and the light emitted thereby from the stimulable phosphor sheet or sheets is photoelectrically read out to obtain electric signals representing the X-ray projection distribution images. The electric signals are processed to obtain a tomographic image of an arbitrary tomographic layer of the object

  9. Computerized accounting methods. Final report

    International Nuclear Information System (INIS)

    1994-01-01

    This report summarizes the results of the research performed under the Task Order on computerized accounting methods in a period from 03 August to 31 December 1994. Computerized nuclear material accounting methods are analyzed and evaluated. Selected methods are implemented in a hardware-software complex developed as a prototype of the local network-based CONMIT system. This complex has been put into trial operation for test and evaluation of the selected methods at two selected ''Kurchatov Institute'' Russian Research Center (''KI'' RRC) nuclear facilities. Trial operation is carried out since the beginning of Initial Physical Inventory Taking in these facilities that was performed in November 1994. Operation of CONMIT prototype system was demonstrated in the middle of December 1994. Results of evaluation of CONMIT prototype system features and functioning under real operating conditions are considered. Conclusions are formulated on the ways of further development of computerized nuclear material accounting methods. The most important conclusion is a need to strengthen computer and information security features supported by the operating environment. Security provisions as well as other LANL Client/Server System approaches being developed by Los Alamos National Laboratory are recommended for selection of software and hardware components to be integrated into production version of CONMIT system for KI RRC

  10. Regional cerebral blood flow during rest and skilled hand movements by xenon-133 inhalation and emission computerized tomography

    International Nuclear Information System (INIS)

    Lauritzen, M.; Henriksen, L.; Lassen, N.A.

    1981-01-01

    Regional cerebral blood flow (CBF) was studied in 16 normal adult volunteers during rest and in 10 the study was repeated during skilled hand movements. A fast-rotating (''dynamic''), single-photon emission computerized tomograph (ECT) with four detector heads was used. Xenon-133 was inhaled over a 1-min period at a concentration of 10 mCi/L. The arrival and washout of the radioisotope was recorded during four 1-min periods. Two slices, 2 cm thick, 7 and 12 cm above the orbitomeatal line were obtained in every study. CBF averaged 60 ml/100 g/min (SD +/- 11) in the lower slice and 51 ml/100 g/min (SD +/- 13) in the upper slice. A symmetric pattern comparing right to left sides was found in both slices. Finger tapping and writing with the right hand increased CBF in specific areas of the upper slice: in the contralateral hand area by 35 +/- 15% (p less than 0.025), and in the supplementary motor area on both sides by 34 +/- 15%

  11. The Effect of College Students' Self-Generated Computerized Mind Mapping on Their Reading Achievement

    Science.gov (United States)

    Sabbah, Sabah Salman

    2015-01-01

    This study explored the potential effect of college students' self-generated computerized mind maps on their reading comprehension. It also investigated the subjects' attitudes toward generating computerized mind maps for reading comprehension. The study was conducted in response to the inability of the foundation-level students, who were learning…

  12. Computerized videodefecography versus defecography: do we need radiographs?

    Directory of Open Access Journals (Sweden)

    Carlos Walter Sobrado

    Full Text Available CONTEXT AND OBJECTIVE: Defecography has been recognized as a valuable method for evaluating patients with evacuation disorders. It consists of the use of static radiography and fluoroscopy to record different situations within anorectal dynamics. Conventionally, rectal parameters are measured using radiograms. It is rare for fluoroscopy alone to be used. Computer software has been developed with the specific aim of calculating these measurements from digitized videotaped images obtained during fluoroscopy, without the need for radiographic film, thereby developing a computerized videodefecography method. The objective was thus to compare measurements obtained via computerized videodefecography with conventional measurements and to discuss the advantages of the new method. DESIGN AND SETTING: Prospective study at the radiology service of Hospital das Clínicas, Universidade de São Paulo. METHOD: Ten consecutive normal subjects underwent videodefecography. The anorectal angle, anorectal junction, puborectalis muscle length, anal canal length and degree of anal relaxation were obtained via the conventional method (using radiography film and via computerized videodefecography using the ANGDIST software. Measurement and analysis of these parameters was performed by two independent physicians. RESULTS: Statistical analysis confirmed that the measurements obtained through direct radiography film assessment and using digital image analysis (computerized videodefecography were equivalent. CONCLUSIONS: Computerized videodefecography is equivalent to the traditional defecography examination. It has the advantage of offering reduced radiation exposure through saving on the use of radiography.

  13. Industrial dynamic tomographic reconstruction; Reconstrucao tomografica dinamica industrial

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Eric Ferreira de

    2016-07-01

    The state of the art methods applied to industrial processes is currently based on the principles of classical tomographic reconstructions developed for tomographic patterns of static distributions, or is limited to cases of low variability of the density distribution function of the tomographed object. Noise and motion artifacts are the main problems caused by a mismatch in the data from views acquired in different instants. All of these add to the known fact that using a limited amount of data can result in the presence of noise, artifacts and some inconsistencies with the distribution under study. One of the objectives of the present work is to discuss the difficulties that arise from implementing reconstruction algorithms in dynamic tomography that were originally developed for static distributions. Another objective is to propose solutions that aim at reducing a temporal type of information loss caused by employing regular acquisition systems to dynamic processes. With respect to dynamic image reconstruction it was conducted a comparison between different static reconstruction methods, like MART and FBP, when used for dynamic scenarios. This comparison was based on a MCNPx simulation as well as an analytical setup of an aluminum cylinder that moves along the section of a riser during the process of acquisition, and also based on cross section images from CFD techniques. As for the adaptation of current tomographic acquisition systems for dynamic processes, this work established a sequence of tomographic views in a just-in-time fashion for visualization purposes, a form of visually disposing density information as soon as it becomes amenable to image reconstruction. A third contribution was to take advantage of the triple color channel necessary to display colored images in most displays, so that, by appropriately scaling the acquired values of each view in the linear system of the reconstruction, it was possible to imprint a temporal trace into the regularly

  14. Computerized radioautographic grain counting

    International Nuclear Information System (INIS)

    McKanna, J.A.; Casagrande, V.A.

    1985-01-01

    In recent years, radiolabeling techniques have become fundamental assays in physiology and biochemistry experiments. They also have assumed increasingly important roles in morphologic studies. Characteristically, radioautographic analysis of structure has been qualitative rather than quantitative, however, microcomputers have opened the door to several methods for quantifying grain counts and density. The overall goal of this chapter is to describe grain counting using the Bioquant, an image analysis package based originally on the Apple II+, and now available for several popular microcomputers. The authors discuss their image analysis procedures by applying them to a study of development in the central nervous system

  15. Computerized occlusal analysis in bruxism

    Directory of Open Access Journals (Sweden)

    Lazić Vojkan

    2006-01-01

    Full Text Available Introduction. Sleep bruxism as nocturnal parafunction, also known as tooth grinding, is the most common parasomnia (sleep disorder. Most tooth grinding occurs during rapid eye movement - REM sleep. Sleep bruxism is an oral habit characterized by rhythmic activity of the masticatory muscles (m. masseter that causes forced contact between dental surfaces during sleep. Sleep bruxism has been associated with craniomandibular disorders including temporomandibular joint discomfort, pulpalgia, premature loss of teeth due to excessive attrition and mobility, headache, muscle ache, sleep interruption of an individual and problems with removable and fixed denture. Basically, two groups of etiological factors can be distinguished, viz., peripheral (occlusal factors and central (pathophysiological and psychological factors. The role of occlusion (occlusal discrepancies as the causative factor is not enough mentioned in relation to bruxism. Objective. The main objective of this paper was to evaluate the connection between occlusal factors and nocturnal parafunctional activities (occlusal disharmonies and bruxism. Method. Two groups were formed- experimental of 15 persons with signs and symptoms of nocturnal parafunctional activity of mandible (mean age 26.6 years and control of 42 persons with no signs and symptoms of bruxism (mean age 26.3 yrs.. The computerized occlusal analyses were performed using the T-Scan II system (Tekscan, Boston, USA. 2D occlusograms were analyzed showing the occlusal force, the center of the occlusal force with the trajectory and the number of antagonistic tooth contacts. Results. Statistically significant difference of force distribution was found between the left and the right side of the arch (L%-R% (t=2.773; p<0.02 in the group with bruxism. The difference of the centre of occlusal force - COF trajectory between the experimental and control group was not significant, but the trajectory of COF was longer in the group of

  16. Computed tomographic appearances of sternocostoclavicular hyperostosis

    Energy Technology Data Exchange (ETDEWEB)

    Chigira, Masaki; Shimizu, Toru (Gunma Univ. (Japan). Dept. of Orthopaedic Surgery)

    1989-08-01

    Computed tomographical analysis of sternocostoclavicular hyperostosis was performed in 27 patients. In the earliest stage hyperostosis occurred around the cartilaginous portion of the first ribs. The sternoclavicular joint space was preserved even in the late stage III of the disorder. It is also suggested that perichondritis and periostitis play important roles in the etiology of this disorder. (orig./GDG).

  17. Computed tomographic appearances of sternocostoclavicular hyperostosis

    International Nuclear Information System (INIS)

    Chigira, Masaki; Shimizu, Toru

    1989-01-01

    Computed tomographical analysis of sternocostoclavicular hyperostosis was performed in 27 patients. In the earliest stage hyperostosis occurred around the cartilaginous portion of the first ribs. The sternoclavicular joint space was preserved even in the late stage III of the disorder. It is also suggested that perichondritis and periostitis play important roles in the etiology of this disorder. (orig./GDG)

  18. Tomographic image reconstruction using training images

    DEFF Research Database (Denmark)

    Soltani, Sara; Andersen, Martin Skovgaard; Hansen, Per Christian

    2017-01-01

    We describe and examine an algorithm for tomographic image reconstruction where prior knowledge about the solution is available in the form of training images. We first construct a non-negative dictionary based on prototype elements from the training images; this problem is formulated within...

  19. Photon emission tomographic apparatus and method

    International Nuclear Information System (INIS)

    Blum, A.S.

    1983-01-01

    Tomographic imaging system employs large area, collimated scintillation detector rotated around radiation emitting subject. Detector support rotates with an inner ring inside a stationary outer ring. Counterbalanced detector support arm is forced by spring action to cause collimator face to follow body contour as detector rotates around the body, thereby reducing collimator to subject distance to improve system resolution. Includes adjustable subject support system

  20. Case Report: Unusual computed tomographic features of ...

    African Journals Online (AJOL)

    A case report of a 57-year old woman who presented with signs and symptoms of intracranial mass. Computed tomographic (CT) and clinical features were unusual and suggestive of a parasaggital Meningioma. However an accurate diagnosis of a tuberculoma was made at surgery and histopathological examination.

  1. Quantum probability measures and tomographic probability densities

    NARCIS (Netherlands)

    Amosov, GG; Man'ko, [No Value

    2004-01-01

    Using a simple relation of the Dirac delta-function to generalized the theta-function, the relationship between the tomographic probability approach and the quantum probability measure approach with the description of quantum states is discussed. The quantum state tomogram expressed in terms of the

  2. The bar coil for NMR tomograph

    International Nuclear Information System (INIS)

    Bogorodzki, P.; Piatkowski, A.; Wasielewski, J.

    1995-01-01

    The bar coil (bi-planar) for the NMR tomograph, designed for medical diagnostics, has been described. The tests of coil shown that it generates good homogenous magnetic field in a big volume what results in improving of the signal-to-noise ratio

  3. Connections model for tomographic images reconstruction

    International Nuclear Information System (INIS)

    Rodrigues, R.G.S.; Pela, C.A.; Roque, S.F. A.C.

    1998-01-01

    This paper shows an artificial neural network with an adequately topology for tomographic image reconstruction. The associated error function is derived and the learning algorithm is make. The simulated results are presented and demonstrate the existence of a generalized solution for nets with linear activation function. (Author)

  4. Computerized intrapartum fetal monitoring

    International Nuclear Information System (INIS)

    Divon, M.Y.

    1986-01-01

    Preliminary clinical evaluation: Twenty healthy women were studied for 40 minutes each. All were at full-term gestation and had taken no medications during pregnancy or labor. The outcome of each of the pregnancies was entirely normal resulting in appropriately grown, non-asphyxiated infants. Results: (1) uterine contractions occupied 34% of the total observation time (mean duration = 67 +- 15 seconds (+- SD)), (2) all fetuses demonstrated FM (mean frequency = 2.5 per 10 minutes; mean duration = 11 seconds). FM were significantly more common during UC., 3) 85% of FHR accelerations were associated with FM as detected by real-time sonography, (4) FHRV rose from 5.1 +- 1.3 (mean +- SD) between UC to 6.0 +- 1.5 during UC, rho < 0.001. This system provides the clinician with clear, objective and concise information which may be useful in early recognition of the compromised fetus

  5. Development and Evaluation of a Confidence-Weighting Computerized Adaptive Testing

    Science.gov (United States)

    Yen, Yung-Chin; Ho, Rong-Guey; Chen, Li-Ju; Chou, Kun-Yi; Chen, Yan-Lin

    2010-01-01

    The purpose of this study was to examine whether the efficiency, precision, and validity of computerized adaptive testing (CAT) could be improved by assessing confidence differences in knowledge that examinees possessed. We proposed a novel polytomous CAT model called the confidence-weighting computerized adaptive testing (CWCAT), which combined a…

  6. Computerizing clinical practice guidelines

    DEFF Research Database (Denmark)

    Lyng, Karen Marie

    It is well described that hospitals have problems with sustaining high quality of care and expedient introduction of new medical knowledge. Clinical practice guidelines (CPGs) have been promoted as a remedy to deal with these problems. It is, however, also well described that application and comp......It is well described that hospitals have problems with sustaining high quality of care and expedient introduction of new medical knowledge. Clinical practice guidelines (CPGs) have been promoted as a remedy to deal with these problems. It is, however, also well described that application...... is comprised by fieldwork in three oncology departments and a case study of advanced life support. Although close to all patients within oncology are treated according to a CPG, I found limited application of physical CPGs and web-based CPG portals. However, I found comprehensive application of activity...... of the business strategic aims, and 3) analysis and formalization of CPGs. This will imply orchestration of design teams with competencies from a wide array of disciplines such as health practice, business management, knowledge management and information systems....

  7. Pain Perception: Computerized versus Traditional Local Anesthesia in Pediatric Patients.

    Science.gov (United States)

    Mittal, M; Kumar, A; Srivastava, D; Sharma, P; Sharma, S

    2015-01-01

    Local anesthetic injection is one of the most anxiety- provoking procedure for both children and adult patients in dentistry. A computerized system for slow delivery of local anesthetic has been developed as a possible solution to reduce the pain related to the local anesthetic injection. The present study was conducted to evaluate and compare pain perception rates in pediatric patients with computerized system and traditional methods, both objectively and subjectively. It was a randomized controlled study in one hundred children aged 8-12 years in healthy physical and mental state, assessed as being cooperative, requiring extraction of maxillary primary molars. Children were divided into two groups by random sampling - Group A received buccal and palatal infiltration injection using Wand, while Group B received buccal and palatal infiltration using traditional syringe. Visual Analog scale (VAS) was used for subjective evaluation of pain perception by patient. Sound, Eye, Motor (SEM) scale was used as an objective method where sound, eye and motor reactions of patient were observed and heart rate measurement using pulse oximeter was used as the physiological parameter for objective evaluation. Patients experienced significantly less pain of injection with the computerized method during palatal infiltration, while less pain was not statistically significant during buccal infiltration. Heart rate increased during both buccal and palatal infiltration in traditional and computerized local anesthesia, but difference between traditional and computerized method was not statistically significant. It was concluded that pain perception was significantly more during traditional palatal infiltration injection as compared to computerized palatal infiltration, while there was no difference in pain perception during buccal infiltration in both the groups.

  8. Tomographic analysis of CBF in cerebral infarction

    International Nuclear Information System (INIS)

    Segawa, Hiromu; Kimura, Kazumoto; Ueda, Yuichi; Nagai, Masakatsu; Yoshimasu, Norio.

    1983-01-01

    Cerebral perfusion was examined in various types of occlusive disease by computed tomographic CBF method. The method utilized has several advantages over conventional studies using isotope, providing high resolution images in a direct relation to CT anatomy. Ten representative cases were presented from 25 consective cases of occlusive disease studied by this method. The method included inhalation of 40 to 60% xenon with serial CT scanning for 25 min. K (build-up rate), lambda (partition coefficient) and CBF values were calculated from ΔHU for each pixel and ΔXe in expired air, based on Fick's principle, and displayed on CRT as K-, lambda- and CBF-map separately. CBF for gray matter of normal control was 82 +- 11 ml/100 gm/min and that for white matter was 24 +- 5 ml/100 gm/min. The ischemic threshold for gray matter appeared to be approximately 20 ml/100 gm/min, as blood flow in focus of complete infarction was below this level. Blood flow between 20 - 30 ml/ 100 gm/min caused some change on CT, such as localized atrophy, cortical thinning, loss of distinction between gray and white matter and decreased or increased density, which were considered to be compatible with pathological changes of laminar necrosis or gliosis with neuronal loss. In a case with occlusion of middle cerebral artery with subsequent recanalization, causing hemorrhagic infarct, hyperemia was observed in the infarcted cortex that was enhanced by iodine. Periventricular lucency observed in two cases, where blood flow was decreased below threshold, could be classified as ''watershed infarction'' mainly involving white matter. In moyamoya disease, blood flow in the anterior circulation was decreased near ischemic level, whereas that in basal ganglia and territory of posterior cerebral artery was fairly preserved, which was compatible with general angiographic finding of this disease. (author)

  9. Computerized tomography of orbital lesions

    International Nuclear Information System (INIS)

    Kuroiwa, Mayumi

    1981-01-01

    Two different types of computerized tomography scanners (CT scanner), i.e. a whole-body CT scanner (GE-CT/T8800) and a cerebral CT scanner (EMI-1010), were compared in the assessment and diagnosis of various orbital lesions. The whole-body CT scanner was found to be advantageous over the cerebral CT scanner for the following reasons: (1) CT images were more informative due to thinner slices associated with smaller-sized and larger-numbered matrices; (2) less artifacts derived from motion of the head or eyeball were produced because of the shorter scanning time; (3) with a devised gantry, coronal dissections were available whenever demanded. (author)

  10. Construction of tomographic head model using sectioned photographic images of cadaver

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Lee, Jai Ki; Park, Jin Seo; Chung, Min Suk

    2004-01-01

    Tomographic models are currently the most complete, developed and realistic models of the human anatomy. They have been used to estimate organ doses for diagnostic radiation examination and radiotherapy treatment planning, and radiation protection. The quality of original anatomic images is a key factor to build a quality tomographic model. Computed tomography (CT) and magnetic resonance imaging (MRI) scan, from which most of current tomographic models are constructed, have their inherent shortcomings. In this study, a tomographic model of Korean adult male head was constructed by using serially sectioned photographs of cadaver. The cadaver was embedded, frozen, serially sectioned and photographed by high resolution digital camera at 0.2 mm interval. The contours of organs and tissues in photographs were segmented by several trained anatomists. The 120 segmented images of head at 2mm interval were converted into binary files and ported into Monte Carlo code to perform an example calculation of organ dose. Whole body tomographic model will be constructed by using the procedure developed in this study

  11. DOE transporation programs - computerized techniques

    Energy Technology Data Exchange (ETDEWEB)

    Joy, D.S.; Johnson, P.E.; Fore, C.S.; Peterson, B.E.

    1983-01-01

    One of the major thrusts of the transportation programs at the Oak Ridge National Laboratory has been the development of a number of computerized transportation programs and data bases. The U.S. Department of Energy (DOE) is supporting these efforts through the Transportation Technology Center at Sandia National Laboratories and the Tranportation Operations and Traffic Management (TOTM) organization at DOE Headquarters. Initially this project was centered upon research activities. However, since these tools provide traffic managers and key personnel involved in preshipment planning with a unique resource for ensuring that the movement of radioactive materials can be properly accomplished, additional interest and support is coming from the operational side of DOE. The major accomplishments include the development of two routing models (one for rail shipments and the other for highway shipments), an emergency response assistance program, and two data bases containing pertinent legislative and regulatory information. This paper discusses the mose recent advances in, and additions to, these computerized techniques and provides examples of how they are used.

  12. Computerized index for teaching files

    International Nuclear Information System (INIS)

    Bramble, J.M.

    1989-01-01

    A computerized index can be used to retrieve cases from a teaching file that have radiographic findings similar to an unknown case. The probability that a user will review cases with a correct diagnosis was estimated with use of radiographic findings of arthritis in hand radiographs of 110 cases from a teaching file. The nearest-neighbor classification algorithm was used as a computer index to 110 cases of arthritis. Each case was treated as an unknown and inputted to the computer index. The accuracy of the computer index in retrieving cases with the same diagnosis (including rheumatoid arthritis, gout, psoriatic arthritis, inflammatory osteoarthritis, and pyrophosphate arthropathy) was measured. A Bayes classifier algorithm was also tested on the same database. Results are presented. The nearest-neighbor algorithm was 83%. By comparison, the estimated accuracy of the Bayes classifier algorithm was 78%. Conclusions: A computerized index to a teaching file based on the nearest-neighbor algorithm should allow the user to review cases with the correct diagnosis of an unknown case, by entering the findings of the unknown case

  13. Reconstruction of tomographic image from x-ray projections of a few views

    International Nuclear Information System (INIS)

    Kobayashi, Fujio; Yamaguchi, Shoichiro

    1982-01-01

    Computer tomographs have progressed rapidly, and in the latest high performance types, the photographing time has been shortened to less than 5 sec, but the clear images of hearts have not yet been obtained. The X-ray tomographs used so far irradiate X-ray from many directions and measure the projected data, but by limiting projection direction to a small number, it was planned to shorter the X-ray photographing time and to reduce X-ray exposure as the objective of this study. In this paper, a method is proposed, by which tomographic images are reconstructed from projected data in a small number of direction by generalized inverse matrix penalty method. This method is the calculation method newly devised by the authors for this purpose. It is a kind of the nonlinear planning method added with the restrictive condition using a generalized inverse matrix, and it is characterized by the simple calculation procedure and rapid convergence. Moreover, the effect on reconstructed images when errors are included in projected data was examined. Also, the simple computer simulation to reconstruct tomographic images using the projected data in four directions was performed, and the usefulness of this method was confirmed. It contributes to the development of superhigh speed tomographs in future. (Kako, I.)

  14. Construction of Korean male tomographic model segmented from PET-CT data

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Park, Sang Kyun; Lee, Jai Ki

    2004-01-01

    Tomographic human models provide currently the most realistic representation of human anatomy for radiation dosimetry calculation. Most of the models have been constructed by using computed tomographic (CT) or magnetic resonance (MR) images obtained from a single individual. Each scan has its inherent advantages and disadvantages. CT scan gives a considerable radiation dose to a subject, and MR scan takes too long time to get clear images of an immobile subject. An emerging source of medical images for the construction of tomographic models is PET-CT, which is performed when looking for cancer. In this study, a tomographic model of Korean adult male was developed by processing whole-body CT images of a PET-CT-scanned healthy volunteer. The 343 slices of the CT images were semi-automatically segmented layer by layer using a graphic software and screen digitizer. The 3rd Korean tomographic model, named KRMAN-2, consisting of 300x150x344 voxels of a size of 2x2x5mm 3 , was constructed. Examples of application to Monte Carlo radiation dosimetry calculation in idealized whole-body irradiations were given and discussed

  15. ULTRASOUND AND COMPUTED TOMOGRAPHIC DIAGNOSIS OF OPTIC NERVE TUMORS

    Directory of Open Access Journals (Sweden)

    S. V. Saakyan

    2012-01-01

    Full Text Available A comprehensive examination was made in 93 patients, including 18 children, with tumors of the optic nerve (ON. Duplex ultrasound scanning was performed in 39 patients, of them there were 11 patients with ON gliomas and 28 with ON meningiomas. The specific computed tomographic and echographic signs of ON glioma and meningiomas were detected. The studies have shown that duplex ultrasound scanning and structural computed tomography of orbital sockets are highly informative complementary imaging procedures for ON tumors, which permits one to make their correct diagnosis, to specify surgical volume, and to plan adequate treatment.

  16. 3D Tomographic Image Reconstruction using CUDA C

    International Nuclear Information System (INIS)

    Dominguez, J. S.; Assis, J. T.; Oliveira, L. F. de

    2011-01-01

    This paper presents the study and implementation of a software for three dimensional reconstruction of images obtained with a tomographic system using the capabilities of Graphic Processing Units(GPU). The reconstruction by filtered back-projection method was developed using the CUDA C, for maximum utilization of the processing capabilities of GPUs to solve computational problems with large computational cost and highly parallelizable. It was discussed the potential of GPUs and shown its advantages to solving this kind of problems. The results in terms of runtime will be compared with non-parallelized implementations and must show a great reduction of processing time. (Author)

  17. Development and validation of the computerized family relations

    NARCIS (Netherlands)

    Skoczen, I.; Cieciuch, J.; Oud, J.H.L.; Welzen, K.F.

    2015-01-01

    The aim of the present study was to develop and investigate the psychometric properties of the Computerized Family Relations Test (CFRT) for children. This test assesses the quality of family relationships with the mother and father from a child's perspective. The CFRT consists of six scales

  18. Procedures for Selecting Items for Computerized Adaptive Tests.

    Science.gov (United States)

    Kingsbury, G. Gage; Zara, Anthony R.

    1989-01-01

    Several classical approaches and alternative approaches to item selection for computerized adaptive testing (CAT) are reviewed and compared. The study also describes procedures for constrained CAT that may be added to classical item selection approaches to allow them to be used for applied testing. (TJH)

  19. Robinson's computerized model of eye muscle mechanics revised.

    NARCIS (Netherlands)

    H.J. Simonsz (Huib)

    1994-01-01

    textabstractThe computerized model of static eye-muscle mechanics developed by Robinson was revised extensively and improved. An extensive literature study yielded additional information on the average diameter of the eye as related to age, on the average location of the insertions and origins of

  20. Quality control of online calibration in computerized assessment

    NARCIS (Netherlands)

    Glas, Cornelis A.W.

    In computerized adaptive testing, updating item parameter estimates using adaptive testing data is often called online calibration. This study investigated how to evaluate whether the adaptive testing data used for online calibration sufficiently fit the item response model used. Three approaches

  1. Quality control of on-line calibration in computerized assessment

    NARCIS (Netherlands)

    Glas, Cornelis A.W.

    1998-01-01

    In computerized adaptive testing, updating parameter estimates using adaptive testing data is often called online calibration. In this paper, how to evaluate whether the adaptive testing model used for online calibration fits the item response model used sufficiently is studied. Three approaches are

  2. Monkeys Exhibit Prospective Memory in a Computerized Task

    Science.gov (United States)

    Evans, Theodore A.; Beran, Michael J.

    2012-01-01

    Prospective memory (PM) involves forming intentions, retaining those intentions, and later executing those intended responses at the appropriate time. Few studies have investigated this capacity in animals. Monkeys performed a computerized task that assessed their ability to remember to make a particular response if they observed a PM cue embedded…

  3. Tomographic imaging of matter using primary and secondary X-and gamma-radiation

    International Nuclear Information System (INIS)

    Holloway, I.E.

    1991-04-01

    Gamma rays may interact with matter by a variety of processes, many of which give rise to secondary radiations. This thesis examines the possibility of performing tomographic imaging by means of these secondary photons using low-cost apparatus. The techniques are compared with each other and with transmission tomography, which plays such an important role in modern diagnostic imaging. The progress of industrial tomography is reviewed as are techniques of investigation using gamma ray scattering in both industry and medicine. Some new applications of a simple gamma ray computerized tomography (CT) scanner have been performed. A method of determining the spatial distribution of pure beta emitters in matter by performing tomographic imaging using the bremsstrahlung radiation produced by the beta particles has been demonstrated. This technique has been shown to permit imaging at depths in material greatly exceeding the range of beta particles in matter. All the imaging techniques using secondary radiation have displayed two principal limitations: long scanning times and poor quantitative accuracy. The low scanning rate results from the small number of secondary photons that are detected. The major contributing factors to poor accuracy are attenuation and the noise produced by unwanted in-scattering. The possible applications for secondary photon imaging have been briefly outlined and some suggestions for future work are included. Although techniques based upon imaging using secondary radiation will not be able to compete with transmission CT in the vast majority of applications, they may prove valuable in a range of specialised fields. (author)

  4. Computerized Classification Testing with the Rasch Model

    Science.gov (United States)

    Eggen, Theo J. H. M.

    2011-01-01

    If classification in a limited number of categories is the purpose of testing, computerized adaptive tests (CATs) with algorithms based on sequential statistical testing perform better than estimation-based CATs (e.g., Eggen & Straetmans, 2000). In these computerized classification tests (CCTs), the Sequential Probability Ratio Test (SPRT) (Wald,…

  5. Present state and development of positron tomographs

    International Nuclear Information System (INIS)

    Allemand, R.; Gariod, R.; Laval, M.; Tournier, F.

    1979-01-01

    This document presents the main characteristics of positron tomographs and analyses the relative importance of the parameters to be taken into consideration in the design of a tomograph: on the one hand, the physical parameters linked to the measurement of the annihilation photons by time coincidence and, on the other, the geometrical and technological parameters of prime importance in minimizing the many spurious effects. The last part endeavours to show this sort of instrumentation has evolved. Using the results obtained in our laboratory by mathematical simulation, the expected advantages are presented on the picture quality of the time of flight measurement of annihilation photons. Where the physical aspects of this method are concerned, the advantage of using cesium fluoride as scintillator is demonstrated [fr

  6. Computerizing primary schools in rural kenya

    DEFF Research Database (Denmark)

    Ogembo, J.G.; Ngugi, B.; Pelowski, Matthew John

    2012-01-01

    questions surrounding this endeavour. Specifically: 1.) what problems do rural schools actually want to solve with computerization; 2.) is computerization the most important priority for rural schools; 3.) are schools ready, in terms of infrastructure, for a computer in the classroom; or 4.) might...... and protective roofing -posing severe challenges to the outstanding conception of computerization. We consider these results and make recommendations for better adapting programs for computer introduction, and also suggest the use of new innovative devices, such as cell phones, which might already have overcome......This paper investigates the outstanding challenges facing primary schools' computerization in rural Kenya. Computerization of schools is often envisaged as a 'magic', or at least a particularly efficient, solution to many of the problems that developing countries face in improving primary school...

  7. The computed tomographic appearances of cherubism

    International Nuclear Information System (INIS)

    Bianchi, S.D.; Boccardi, A.; Mela, F.; Romagnoli, R.

    1987-01-01

    The computed tomographic (CT) aspects of six cases of cherubism are described. Through its optimal representation of the lesions, CT enabled certain characteristics of this disease to be substantiated, namely, limitation of the process to the bones of the jaw and primarily superficial development of the mandibular lesions, coupled with an unusual mandibular condylar impairment. Moreover, the composition of this series permitted investigation of the condition in its several stages of progression. (orig.)

  8. Tomographic scanning apparatus with ionization detector means

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus using a fan beam and digital output signal. Particular reference is made to the gas-pressurized ionization detector chamber, consisting of an array of side-by-side elongate ionization detection cells, the principal axis of each of the said cells being oriented along a radius extending towards the radiation source, and connection means for applying potentials across the cells for taking their output signals. (U.K.)

  9. Tomographic extreme-ultraviolet spectrographs: TESS.

    Science.gov (United States)

    Cotton, D M; Stephan, A; Cook, T; Vickers, J; Taylor, V; Chakrabarti, S

    2000-08-01

    We describe the system of Tomographic Extreme Ultraviolet (EUV) SpectrographS (TESS) that are the primary instruments for the Tomographic Experiment using Radiative Recombinative Ionospheric EUV and Radio Sources (TERRIERS) satellite. The spectrographs were designed to make high-sensitivity {80 counts/s)/Rayleigh [one Rayleigh is equivalent to 10(6) photons/(4pi str cm(2)s)}, line-of-sight measurements of the oi 135.6- and 91.1-nm emissions suitable for tomographic inversion. The system consists of five spectrographs, four identical nightglow instruments (for redundancy and added sensitivity), and one instrument with a smaller aperture to reduce sensitivity and increase spectral resolution for daytime operation. Each instrument has a bandpass of 80-140 nm with approximately 2- and 1-nm resolution for the night and day instruments, respectively. They utilize microchannel-plate-based two-dimensional imaging detectors with wedge-and-strip anode readouts. The instruments were designed, fabricated, and calibrated at Boston University, and the TERRIERS satellite was launched on 18 May 1999 from Vandenberg Air Force Base, California.

  10. Relationship between lung function and quantitative computed tomographic parameters of airway remodeling, air trapping, and emphysema in patients with asthma and chronic obstructive pulmonary disease: A single-center study.

    Science.gov (United States)

    Hartley, Ruth A; Barker, Bethan L; Newby, Chris; Pakkal, Mini; Baldi, Simonetta; Kajekar, Radhika; Kay, Richard; Laurencin, Marie; Marshall, Richard P; Sousa, Ana R; Parmar, Harsukh; Siddiqui, Salman; Gupta, Sumit; Brightling, Chris E

    2016-05-01

    There is a paucity of studies comparing asthma and chronic obstructive pulmonary disease (COPD) based on thoracic quantitative computed tomographic (QCT) parameters. We sought to compare QCT parameters of airway remodeling, air trapping, and emphysema between asthmatic patients and patients with COPD and explore their relationship with airflow limitation. Asthmatic patients (n = 171), patients with COPD (n = 81), and healthy subjects (n = 49) recruited from a single center underwent QCT and clinical characterization. Proximal airway percentage wall area (%WA) was significantly increased in asthmatic patients (62.5% [SD, 2.2]) and patients with COPD (62.7% [SD, 2.3]) compared with that in healthy control subjects (60.3% [SD, 2.2], P Emphysema assessed based on lung density measured by using Hounsfield units below which 15% of the voxels lie (Perc15) was a feature of COPD only (patients with COPD: mean, -964 [SD, 19.62] vs asthmatic patients: mean, -937 [SD, 22.7] and healthy subjects: mean, -937 [SD, 17.1], P < .001). Multiple regression analyses showed that the strongest predictor of lung function impairment in asthmatic patients was %WA, whereas in the COPD and asthma subgrouped with postbronchodilator FEV1 percent predicted value of less than 80%, it was air trapping. Factor analysis of QCT parameters in asthmatic patients and patients with COPD combined determined 3 components, with %WA, air trapping, and Perc15 values being the highest loading factors. Cluster analysis identified 3 clusters with mild, moderate, or severe lung function impairment with corresponding decreased lung density (Perc15 values) and increased air trapping. In asthmatic patients and patients with COPD, lung function impairment is strongly associated with air trapping, with a contribution from proximal airway narrowing in asthmatic patients. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Lamb-Wave-Based Tomographic Imaging Techniques for Hole-Edge Corrosion Monitoring in Plate Structures

    Directory of Open Access Journals (Sweden)

    Dengjiang Wang

    2016-11-01

    Full Text Available This study presents a novel monitoring method for hole-edge corrosion damage in plate structures based on Lamb wave tomographic imaging techniques. An experimental procedure with a cross-hole layout using 16 piezoelectric transducers (PZTs was designed. The A0 mode of the Lamb wave was selected, which is sensitive to thickness-loss damage. The iterative algebraic reconstruction technique (ART method was used to locate and quantify the corrosion damage at the edge of the hole. Hydrofluoric acid with a concentration of 20% was used to corrode the specimen artificially. To estimate the effectiveness of the proposed method, the real corrosion damage was compared with the predicted corrosion damage based on the tomographic method. The results show that the Lamb-wave-based tomographic method can be used to monitor the hole-edge corrosion damage accurately.

  12. Tomographic images of cerebral blood flow using a slant hole collimator

    International Nuclear Information System (INIS)

    Wraight, E.P.; Barber, R.W.; Crossland, P.; Maltby, P.

    1983-01-01

    The feasibility of using a rotating slant hole (RSH) collimator on simple tomographic equipment such as a standard gamma camera interfaced to a general purpose Nuclear Medicine computer is reported for producing images of cerebral blood flow following the administration of 123 I-iodoamphetamine to patients. Initial studies produced satisfactory images, thus opening the possibility of tomographic cerebral blood flow imaging to centres not possessing sophisticated tomographic equipment. Planar resolution is superior to that reported for a 25 0 RSH collimator. Axial resolution is not as good at small source distances but is comparable at distances beyond 10 cm. Sensitivity is comparable to other RSH collimators and is similar to Technicare's parallel hole general all purpose collimator. (UK)

  13. Psychometrics behind Computerized Adaptive Testing.

    Science.gov (United States)

    Chang, Hua-Hua

    2015-03-01

    The paper provides a survey of 18 years' progress that my colleagues, students (both former and current) and I made in a prominent research area in Psychometrics-Computerized Adaptive Testing (CAT). We start with a historical review of the establishment of a large sample foundation for CAT. It is worth noting that the asymptotic results were derived under the framework of Martingale Theory, a very theoretical perspective of Probability Theory, which may seem unrelated to educational and psychological testing. In addition, we address a number of issues that emerged from large scale implementation and show that how theoretical works can be helpful to solve the problems. Finally, we propose that CAT technology can be very useful to support individualized instruction on a mass scale. We show that even paper and pencil based tests can be made adaptive to support classroom teaching.

  14. Chinese computerized nuclear data library

    International Nuclear Information System (INIS)

    Liang Qichang; Cai Dunjiu

    1996-01-01

    The Second Version of Chinese Evaluated Nuclear Data Library (CENDL-2) includes the complete neutron nuclear data sets of 54 important elements and isotopes used for nuclear science and engineering with the incident neutron energy from 10 -5 eV to 20 MeV, the international universal format ENDF/B-6 was adopted. Now, the Chinese Computerized nuclear data library has been developed and put into operation. That is, the users can make on-line use of the main data libraries for evaluated neutron reaction data in the world of EXFOR experimental nuclear data library on the terminal of computer via the perfect computer software system, carry out directly the nuclear engineering calculation or nuclear data evaluation, enjoy the use of the resource of our nuclear data libraries for their development of nuclear energy and nuclear technology applications

  15. Computerized evaluation of flood impact

    International Nuclear Information System (INIS)

    Gagnon, J.; Quach, T.T.; Marche, C.; Lessard, G.

    1998-01-01

    A computerized evaluation process for assessing the economic impacts of a potential dam failure is described. The DOMINO software, which was developed by Hydro-Quebec, takes into account flow data from dam break simulations of floods, the territory involved, plus the economic evaluations of the real estate and infrastructures affected. Some examples of software applications and impact evaluations are presented. The principal elements involved in estimating economic or other types of impacts induced by natural flooding or dam failure, are: (1) flow forecasting, (2) defining the contour of the involved territory, and (3) accounting for the various impacts identified in the affected zone. Owing to its wide range of functions and utilities, DOMINO has proven to be a very useful, user-friendly and portable decision-making tool. 5 refs., 6 tabs

  16. Termination Criteria for Computerized Classification Testing

    Directory of Open Access Journals (Sweden)

    Nathan A. Thompson

    2011-02-01

    Full Text Available Computerized classification testing (CCT is an approach to designing tests with intelligent algorithms, similar to adaptive testing, but specifically designed for the purpose of classifying examinees into categories such as - pass- and - fail.- Like adaptive testing for point estimation of ability, the key component is the termination criterion, namely the algorithm that decides whether to classify the examinee and end the test or to continue and administer another item. This paper applies a newly suggested termination criterion, the generalized likelihood ratio (GLR, to CCT. It also explores the role of the indifference region in the specification of likelihood-ratio based termination criteria, comparing the GLR to the sequential probability ratio test. Results from simulation studies suggest that the GLR is always at least as efficient as existing methods.

  17. An original emission tomograph for in vivo brain imaging of small animals

    International Nuclear Information System (INIS)

    Ochoa, A.V.; Ploux, L.; Mastrippolito, R.

    1996-01-01

    The principle of a new tomograph TOHR dedicated for small volume analysis with very high resolution is presented in this paper. We use uncorrelated multi-photons (X or gamma rays) radioisotopes and a large solid angle focusing collimator to make tomographic imaging without reconstruction algorithm. With this original device, detection efficiency and resolution are independent and submillimetric resolution can be achieved. A feasibility study shows that, made achieve the predicted performances of TOHR. We discuss its potential in rat brain tomography by simulating a realistic neuropharmacological experiment using a 1.4 mm resolution prototype of TOHR under development

  18. Antipsychotic treatment in schizophrenia: the role of computerized neuropsychological assessment.

    Science.gov (United States)

    Kertzman, Semion; Reznik, Ilya; Grinspan, Haim; Weizman, Abraham; Kotler, Moshe

    2008-01-01

    The present study analyzes the role of neurocognitive assessment instruments in the detection of the contribution of antipsychotic treatment to cognitive functioning. Recently, a panel of experts suggested six main domains (working memory; attention/vigilance; verbal/visual learning and memory; reasoning and problem solving; speed of processing) implicated in schizophrenia-related cognitive deficits, which serve as a theoretical base for creation of real-time computerized neurocognitive batteries. The high sensitivity of computerized neuropsychological testing is based on their ability to adopt the reaction time (RT) paradigm for the assessment of brain function in a real-time regime. This testing is highly relevant for the monitoring of the cognitive effects of antipsychotics. Computerized assessment assists in the identification of state- and trait-related cognitive impairments. The optimal real-time computerized neurocognitive battery should composite balance between broad and narrow coverage of cognitive domains relevant to the beneficial effects of antipsychotics and will enable better planning of treatment and rehabilitation programs.

  19. Full three-dimensional relocation and tomographic inversion of the 1977-2008 earthquakes in north-eastern Italy: a feasibility study

    Directory of Open Access Journals (Sweden)

    Aldo Vesnaver

    2013-04-01

    Full Text Available In a regional seismological network, the estimation of the epicenter is usually robust, especially for events inside or close to the network boundaries. In contrast, the hypocentral depth is very sensitive to the assumed velocity field. In this study, we compare the hypocenter estimates obtained by a classical algorithm in a simple one-dimensional (1D model with a recently developed full 3D model that is based on shrinking grids. This study is preliminary, as the 3D Earth model is based on limited data from the literature; however, it demonstrates that different patterns show up when a more representative geological model is adopted. This encourages further studies, based on fully integrated 3D models from active surface seismic, well data and other geophysical measurements. Such an integrated approach has been successfully adopted by the oil and gas industries for decades, which has increased the exploration success rate and the production of hydrocarbon reservoirs.

  20. Spontaneous Intracerebral Hemorrhage: Computed Tomographic Characteristics and Outcome

    Directory of Open Access Journals (Sweden)

    Aimara de la Caridad Vergara Santos

    2015-12-01

    Full Text Available Background: strokes are the third leading cause of death among adults and 10-15 % of them are due to spontaneous intracerebral hemorrhage. Objective: to characterize spontaneous intracerebral hemorrhage through computed tomography scan and its outcome. Methods: a case series study was conducted comprising patients diagnosed with spontaneous intracerebral hemorrhage admitted to the Arnaldo Milián Castro Provincial University Hospital in Villa Clara from January 2009 to January 2010. Tomographic variables of interest were derived from evaluation of spontaneous intracerebral hematomas. Results: fifty-nine cases of spontaneous intracerebral hemorrhage were studied, 23 were located in lobar regions, 4 had severe midline shift, and 2 showed volume greater than 80 ml. Eight out of eleven with extension into the ventricular system had an unfavorable outcome. Among those with thalamic hemorrhage, patients with diameter larger than 4cm and extension into the ventricular system died. Patients with putaminal hemorrhage larger than 4 cm and posterior fossa hematoma with hydrocephalus had a poor outcome, as well as most individuals (55 with other mass effects. Most lobar hematomas (14 out of 23 had a satisfactory outcome, unlike cerebellar and brainstem hematomas. Conclusions: tomographic variables that had a negative impact on the outcome were: volume greater than 80 ml, severe midline shift, diameter larger than 4 cm, extension into the ventricular system, hydrocephalus, other signs of mass effect and brainstem location.

  1. Clinical findings in 16 patients with tomographic diagnosis of schizencephaly

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Maria do Carmo de Souza [Universidade Federal do Espirito Santo, Vitoria, ES (Brazil). Hospital Universitario Cassiano Antonio Moraes]. E-mail: rodriguesmcs@yahoo.com.br; Monteiro, Alexandra Maria Vieira [Universidade do Estado do Rio de Janeiro, RJ (Brazil). Faculdade de Ciencias Medicas; Llerena Junior, Juan Clinton [Fundacao Oswaldo Cruz, Rio de Janeiro, RJ (Brazil). Instituto Fernandes Figueira. Centro de Genetica Medica; Fernandes, Alexandre Ribeiro [Universidade Gama Filho, Rio de Janeiro, RJ (Brazil). Dept. de Pediatria

    2006-09-15

    Objective: to establish a correlation between clinical features in a group of children with tomographic diagnosis of schizencephaly and clefts extent and localization. Materials and methods: retrospective study of dossiers from the archives of Neurology and Medical Genetics Services at Instituto Fernandes Figueira/FIOCRUZ and Hospital Municipal Jesus, Rio de Janeiro, RJ, Brazil, in the period between 2000 and 2003. The study included 16 patients, nine female and seven male, with tomographic diagnosis of schizencephaly investigated for clinical findings, psychomotor development, motor/cognitive deficits and epilepsy. Results: predominance of bilateral clefts in 10:16 patients, open-lip schizencephaly type in 23:27 patients, and small lips in 11:27 patients. As regards anomalies associated with schizencephaly, pellucid septum absence was the most frequent one (10:16 patients). As regards clinical findings, 15 patients presented with developmental delay and motor deficit, six patients with cognitive deficit and ten with epilepsy. In three patients, we observed discordant clinical findings and cleft sizes, although the clefts were small, the clinical features severity was high because of other cerebral anomalies. Conclusion: the clinical features of schizencephaly are related to the size of the clefts, regardless laterality, presenting higher severity when associated with other cerebral anomalies. (author)

  2. Clinical findings in 16 patients with tomographic diagnosis of schizencephaly

    International Nuclear Information System (INIS)

    Rodrigues, Maria do Carmo de Souza; Monteiro, Alexandra Maria Vieira; Llerena Junior, Juan Clinton; Fernandes, Alexandre Ribeiro

    2006-01-01

    Objective: to establish a correlation between clinical features in a group of children with tomographic diagnosis of schizencephaly and clefts extent and localization. Materials and methods: retrospective study of dossiers from the archives of Neurology and Medical Genetics Services at Instituto Fernandes Figueira/FIOCRUZ and Hospital Municipal Jesus, Rio de Janeiro, RJ, Brazil, in the period between 2000 and 2003. The study included 16 patients, nine female and seven male, with tomographic diagnosis of schizencephaly investigated for clinical findings, psychomotor development, motor/cognitive deficits and epilepsy. Results: predominance of bilateral clefts in 10:16 patients, open-lip schizencephaly type in 23:27 patients, and small lips in 11:27 patients. As regards anomalies associated with schizencephaly, pellucid septum absence was the most frequent one (10:16 patients). As regards clinical findings, 15 patients presented with developmental delay and motor deficit, six patients with cognitive deficit and ten with epilepsy. In three patients, we observed discordant clinical findings and cleft sizes, although the clefts were small, the clinical features severity was high because of other cerebral anomalies. Conclusion: the clinical features of schizencephaly are related to the size of the clefts, regardless laterality, presenting higher severity when associated with other cerebral anomalies. (author)

  3. A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology

    International Nuclear Information System (INIS)

    Staton, R J; Pazik, F D; Nipper, J C; Williams, J L; Bolch, W E

    2003-01-01

    Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult

  4. Reduction of thoracic aorta motion artifact with high-pitch 128-slice dual-source computed tomographic angiography: a historical control study.

    Science.gov (United States)

    Nakagawa, Junichiro; Tasaki, Osamu; Watanabe, Yoshiyuki; Azuma, Takeo; Ohnishi, Mitsuo; Ukai, Isao; Tahara, Kenichi; Ogura, Hiroshi; Kuwagata, Yasuyuki; Hamasaki, Toshimitsu; Shimazu, Takeshi

    2013-01-01

    Electrocardiogram-gated imaging combined with multi-detector row computed tomography (MDCT) has reduced cardiac motion artifacts, but it was not practical in the emergency setting. The purpose of this study was to evaluate the ability of a high-pitch, 128-slice dual-source CT (DSCT) scanner to reduce motion artifacts in patients admitted to the emergency room. This study comprised 100 patients suspected of having thoracic aorta lesions. We examined 47 patients with the 128-slice DSCT scanner (DSCT group), and 53 patients were examined with a 64-slice MDCT scanner (MDCT group). Six anatomic areas in the thoracic aorta were evaluated. Computed tomography images in the DSCT group were distinct, and significant differences were observed in images of all areas between the 2 groups except for the descending aorta. The high-pitch DSCT scanner can reduce motion artifacts of the thoracic aorta and enable radiological diagnosis even in patients with tachycardia and without breath hold.

  5. Comparative study of reconstruction filters for cranio examinations of the Philips system and its influence on the quality of the tomographic image

    International Nuclear Information System (INIS)

    Silveira, V.C.; Kodlulovich, S.; Delduck, R.S.; Oliveira, L.C.G.

    2011-01-01

    The aim of this study was to evaluate different reconstruction algorithm (kernels) applied for head examinations. The research was carried out using 40-slice MDCT (Philips, Brilliance 40 CT scanner) and an ACR Phantoms to evaluate the image quality. The doses were estimated applying the coefficients obtained by IMPACT .The study showed that independently of the filter used the values of CT number have no change. The low contrast showed that the choice of correct filter might result a decrease of 9% of doses values. For special resolution, the sharp filter showed a better response for low m As. The noise value of image to certain filters smooth has no changed, even by reducing the m As values. (author)

  6. Accuracy of the Heidelberg Spectralis in the alignment between near-infrared image and tomographic scan in a model eye: a multicenter study.

    Science.gov (United States)

    Barteselli, Giulio; Bartsch, Dirk-Uwe; Viola, Francesco; Mojana, Francesca; Pellegrini, Marco; Hartmann, Kathrin I; Benatti, Eleonora; Leicht, Simon; Ratiglia, Roberto; Staurenghi, Giovanni; Weinreb, Robert N; Freeman, William R

    2013-09-01

    To evaluate temporal changes and predictors of accuracy in the alignment between simultaneous near-infrared image and optical coherence tomography (OCT) scan on the Heidelberg Spectralis using a model eye. Laboratory investigation. After calibrating the device, 6 sites performed weekly testing of the alignment for 12 weeks using a model eye. The maximum error was compared with multiple variables to evaluate predictors of inaccurate alignment. Variables included the number of weekly scanned patients, total number of OCT scans and B-scans performed, room temperature and its variation, and working time of the scanning laser. A 4-week extension study was subsequently performed to analyze short-term changes in the alignment. The average maximum error in the alignment was 15 ± 6 μm; the greatest error was 35 μm. The error increased significantly at week 1 (P = .01), specifically after the second imaging study (P alignment were temperature variation and scans per patient (P imaging study. To improve the accuracy, room temperature should be kept stable and unnecessary scans should be avoided. The alignment of the device does not need to be checked on a regular basis in the clinical setting, but it should be checked after every other patient for more precise research purposes. Published by Elsevier Inc.

  7. Spiral computed tomographic pulmonary angiography in patients with acute pulmonary emboli and no pre-existing comorbidity: a prospective prognostic panel study

    Energy Technology Data Exchange (ETDEWEB)

    Javadrashid, Reza; Mozayan, Maryam; Tarzamni, Mohammad Kazem [Imam Reza Teaching Hospital, Tabriz University of Medical Sciences, Department of Radiology, Tabriz (Iran, Islamic Republic of); Ghaffari, Mohammad Reza [Imam Reza Teaching Hospital, Tabriz University of Medical Sciences, Department of Lung and Respiratory Disease, Tabriz (Iran, Islamic Republic of); Fouladi, Daniel F. [Tabriz University of Medical Sciences, Drug Applied Research Center, Tabriz (Iran, Islamic Republic of)

    2015-01-15

    To investigate the prognostic validity of the right ventricular to left ventricular diameter (RVD/LVD) ratio and Qanadli pulmonary artery obstruction score (PAOS) in hemodynamically stable patients with no pre-existing comorbidities. Sixty-three patients with no previous comorbidity were recruited for this study. The RVD/LVD ratio was calculated based on axial image measurements obtained from contrast-enhanced non-electrocardiography-gated spiral computed tomography (CT) pulmonary angiographic studies. Patients were followed up for 60 days after the initial CT and study variables including demographic data, the RVD/LVD ratio and PAOS were compared between deceased cases and survivors via univariate and multivariate statistical models. The 60-day mortality rate was 22.2 %. The deceased and surviving groups were comparable for PAOS, whereas both the median age and RVD/LVD ratio were significantly higher in the first group. In multivariate analysis, however, age was the only significant, independent predictor of 60-day mortality (p = 0.02, Exp(B) = 1.06). At a cut-off age of 63 years the 60-day mortality was predicted with a sensitivity and specificity of 64.3 % and 69.4 %, respectively. The RVD/LVD ratio and PAOS are not independent predictors of mortality in hemodynamically stable patients with acute PE and no pre-existing comorbidities. (orig.)

  8. Evaluation of the Self-Adjusting File system (SAF) for the instrumentation of primary molar root canals: a micro-computed tomographic study.

    Science.gov (United States)

    Kaya, E; Elbay, M; Yiğit, D

    2017-06-01

    The Self-Adjusting File (SAF) system has been recommended for use in permanent teeth since it offers more conservative and effective root-canal preparation when compared to traditional rotary systems. However, no study had evaluated the usage of SAF in primary teeth. The aim of this study was to evaluate and compare the use of SAF, K file (manual instrumentation) and Profile (traditional rotary instrumentation) systems for primary-tooth root-canal preparation in terms of instrumentation time and amounts of dentin removed using micro-computed tomography (μCT) technology. Study Design: The study was conducted with 60 human primary mandibular second molar teeth divided into 3 groups according to instrumentation technique: Group I: SAF (n=20); Group II: K file (n=20); Group III; Profile (n=20). Teeth were embedded in acrylic blocks and scanned with a μCT scanner prior to instrumentation. All distal root canals were prepared up to size 30 for K file,.04/30 for Profile and 2 mm thickness, size 25 for SAF; instrumentation time was recorded for each tooth, and a second μCT scan was performed after instrumentation was complete. Amounts of dentin removed were measured using the three-dimensional images by calculating the difference in root-canal volume before and after preparation. Data was statistically analysed using the Kolmogorov-Smirnov and Kruskal-Wallis tests. Manual instrumentation (K file) resulted in significantly more dentin removal when compared to rotary instrumentation (Profile and SAF), while the SAF system generated significantly less dentin removal than both manual instrumentation (K file) and traditional rotary instrumentation (Profile) (psystems. Within the experimental conditions of the present study, the SAF seems as a useful system for root-canal instrumentation in primary molars because it removed less dentin than other systems, which is especially important for the relatively thin-walled canals of primary teeth, and because it involves less

  9. Virtual autopsy with multiphase postmortem computed tomographic angiography versus traditional medical autopsy to investigate unexpected deaths of hospitalized patients: a cohort study.

    Science.gov (United States)

    Wichmann, Dominic; Heinemann, Axel; Weinberg, Clemens; Vogel, Hermann; Hoepker, Wilhelm Wolfgang; Grabherr, Silke; Pueschel, Klaus; Kluge, Stefan

    2014-04-15

    "Virtual" autopsy by postmortem computed tomography (PMCT) can replace medical autopsy to a certain extent but has limitations for cardiovascular diseases. These limitations might be overcome by adding multiphase PMCT angiography. To compare virtual autopsy by multiphase PMCT angiography with medical autopsy. Prospective cohort study. (ClinicalTrials.gov: NCT01541995) SETTING: Single-center study at the University Medical Center Hamburg-Eppendorf, Hamburg, Germany, between 1 April 2012 and 31 March 2013. Hospitalized patients who died unexpectedly or within 48 hours of an event necessitating cardiopulmonary resuscitation. Diagnoses from clinical records were compared with findings from both types of autopsy. New diagnoses identified by autopsy were classified as major or minor, depending on whether they would have altered clinical management. Of 143 eligible patients, 50 (35%) had virtual and medical autopsy. Virtual autopsy confirmed 93% of all 336 diagnoses identified from antemortem medical records, and medical autopsy confirmed 80%. In addition, virtual and medical autopsy identified 16 new major and 238 new minor diagnoses. Seventy-three of the virtual autopsy diagnoses, including 32 cases of coronary artery stenosis, were identified solely by multiphase PMCT angiography. Of the 114 clinical diagnoses classified as cardiovascular, 110 were confirmed by virtual autopsy and 107 by medical autopsy. In 11 cases, multiphase PMCT angiography showed "unspecific filling defects," which were not reported by medical autopsy. These results come from a single center with concerted interest and expertise in postmortem imaging; further studies are thus needed for generalization. In cases of unexpected death, the addition of multiphase PMCT angiography increases the value of virtual autopsy, making it a feasible alternative for quality control and identification of diagnoses traditionally made by medical autopsy. University Medical Center Hamburg-Eppendorf.

  10. Three dimensional analysis of impacted maxillary third molars: A cone-beam computed tomographic study of the position and depth of impaction

    Energy Technology Data Exchange (ETDEWEB)

    De Andrade, Priscila Ferreira; Silva, Jesca Neftali Nogueira; Sotto-Maior, Bruno Sales; Devito, Karina Lopes; Assis, Neuza Maria Souza Picorelli [Faculty of Dentistry, Federal University of Juiz de Fora, Juiz de Fora (Brazil); Ribeiro, CleideGisele [Faculty of Medical and Health Sciences - SUPREMA, Juiz de Fora (Brazil)

    2017-09-15

    The classification of impacted maxillary third molars (IMTMs) facilitates interdisciplinary communication and helps estimate the degree of surgical difficulty. Thus, this study aimed to develop a 3-dimensional classification of the position and depth of impaction of IMTMs and to estimate their prevalence with respect to gender and age. This cross-sectional retrospective study analyzed images in sagittal and coronal cone-beam computed tomography (CBCT) sections of 300 maxillary third molars. The proposed classification was based on 3 criteria: buccolingual position (buccal, lingual, or central), mesial-distal position (mesioangular, vertical, or distoangular), and depth of impaction (low, medium, or high). CBCT images of IMTMs were classified, and the associations of the classifications with gender and age were examined using analysis of variance with the Scheffé post-hoc test. To determine the associations among the 3 classifications, the chi-square test was used (P<.05). No significant association of the classifications with gender was observed. Age showed a significant relationship with depth of impaction (P=.0001) and mesial-distal position (P=.005). The most common positions were buccal (n=222), vertical (n=184), and low (n=124). Significant associations among the 3 tested classifications were observed. CBCT enabled the evaluation of IMTMs in a 3-dimensional format, and we developed a proposal for a new classification of the position and depth of impaction of IMTMs.

  11. Computerized Clinical Decision Support: Contributions from 2015

    Science.gov (United States)

    Bouaud, J.

    2016-01-01

    Summary Objective To summarize recent research and select the best papers published in 2015 in the field of computerized clinical decision support for the Decision Support section of the IMIA yearbook. Method A literature review was performed by searching two bibliographic databases for papers related to clinical decision support systems (CDSSs) and computerized provider order entry (CPOE) systems. The aim was to identify a list of candidate best papers from the retrieved papers that were then peer-reviewed by external reviewers. A consensus meeting between the two section editors and the IMIA editorial team was finally conducted to conclude in the best paper selection. Results Among the 974 retrieved papers, the entire review process resulted in the selection of four best papers. One paper reports on a CDSS routinely applied in pediatrics for more than 10 years, relying on adaptations of the Arden Syntax. Another paper assessed the acceptability and feasibility of an important CPOE evaluation tool in hospitals outside the US where it was developed. The third paper is a systematic, qualitative review, concerning usability flaws of medication-related alerting functions, providing an important evidence-based, methodological contribution in the domain of CDSS design and development in general. Lastly, the fourth paper describes a study quantifying the effect of a complex, continuous-care, guideline-based CDSS on the correctness and completeness of clinicians’ decisions. Conclusions While there are notable examples of routinely used decision support systems, this 2015 review on CDSSs and CPOE systems still shows that, despite methodological contributions, theoretical frameworks, and prototype developments, these technologies are not yet widely spread (at least with their full functionalities) in routine clinical practice. Further research, testing, evaluation, and training are still needed for these tools to be adopted in clinical practice and, ultimately, illustrate

  12. A comparative study of the radiobiologic risks from three different TMJ (temporary modular joint) radiographic techniques using a pan-tomographic system

    International Nuclear Information System (INIS)

    Chilvarquer, Israel.

    1992-01-01

    The aim of this study was the obtention of the absorbed doses to critical organs for evaluating and comparing the radiobiologic risks from three different TMJ radiographic techniques, using a pantomographic system, utilizing a combination of rare-earth screens to fast films. The compared techniques were the conventional panoramic technique, the Manufacture's recommended technique for TMJ and the Chilvarquer's technique. The absorber doses were measured by exposing a phantom, fitted with fluoride TLD in fourteen sites distributed at the Thyroid, Pituitary, Salivary glands sites distributed at the Thyroid, Pituitary, Salivary glands and at the bone marrow. The radiobiologic risks were calculated using the UNSCEAR 34 (1977), and the fatal cancer incidence for age and sex was calculated using the ICRP 29 (1977). Based on the obtained data, it was concluded that the Chilvarquer's technique induced the lowest absorbed doses and the estimated radiobiologic risks were lower than a cancer per a million of examinations. (author). 108 refs., 19 figs., 14 tabs

  13. [Computerized medical record: deontology and legislation].

    Science.gov (United States)

    Allaert, F A; Dusserre, L

    1996-02-01

    Computerization of medical records is making headway for patients' follow-up, scientific research, and health expenses control, but it must not alter the guarantees provided to the patients by the medical code of ethics and the law of January 6, 1978. This law, modified on July 1, 1994, requires to register all computerized records of personal data and establishes rights to protect privacy against computer misdemeanor. All medical practitioners using computerized medical records must be aware that the infringement of this law may provoke suing in professional, civil or criminal court.

  14. Microcomputer Network for Computerized Adaptive Testing (CAT)

    Science.gov (United States)

    1984-03-01

    PRDC TR 84-33 \\Q.�d-33- \\ MICROCOMPUTER NETWOJlt FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ) Baldwin Quan Thomas A . Park Gary Sandahl John H...ACCEIIION NO NPRDC TR 84-33 4. TITLE (-d Sul>tlllo) MICROCOMP UTER NETWORK FOR COMPUTERIZED ADA PTIVE TESTING ( CAT ) 1. Q B. uan T. A . Park...adaptive testing ( CAT ) Bayesian sequential testing 20. ABSTitACT (Continuo on ro•••• aide II noco .. _, _., ld-tlly ,.,. t.loclt _._.) DO Computerized

  15. Prospective, Head-to-Head Study of Three Computerized Neurocognitive Assessment Tools (CNTs): Reliability and Validity for the Assessment of Sport-Related Concussion.

    Science.gov (United States)

    Nelson, Lindsay D; LaRoche, Ashley A; Pfaller, Adam Y; Lerner, E Brooke; Hammeke, Thomas A; Randolph, Christopher; Barr, William B; Guskiewicz, Kevin; McCrea, Michael A

    2016-01-01

    Limited data exist comparing the performance of computerized neurocognitive tests (CNTs) for assessing sport-related concussion. We evaluated the reliability and validity of three CNTs-ANAM, Axon Sports/Cogstate Sport, and ImPACT-in a common sample. High school and collegiate athletes completed two CNTs each at baseline. Concussed (n=165) and matched non-injured control (n=166) subjects repeated testing within 24 hr and at 8, 15, and 45 days post-injury. Roughly a quarter of each CNT's indices had stability coefficients (M=198 day interval) over .70. Group differences in performance were mostly moderate to large at 24 hr and small by day 8. The sensitivity of reliable change indices (RCIs) was best at 24 hr (67.8%, 60.3%, and 47.6% with one or more significant RCIs for ImPACT, Axon, and ANAM, respectively) but diminished to near the false positive rates thereafter. Across time, the CNTs' sensitivities were highest in those athletes who became asymptomatic within 1 day before neurocognitive testing but was similar to the tests' false positive rates when including athletes who became asymptomatic several days earlier. Test-retest reliability was similar among these three CNTs and below optimal standards for clinical use on many subtests. Analyses of group effect sizes, discrimination, and sensitivity and specificity suggested that the CNTs may add incrementally (beyond symptom scores) to the identification of clinical impairment within 24 hr of injury or within a short time period after symptom resolution but do not add significant value over symptom assessment later. The rapid clinical recovery course from concussion and modest stability probably jointly contribute to limited signal detection capabilities of neurocognitive tests outside a brief post-injury window. (JINS, 2016, 22, 24-37).

  16. Single photon emission computed tomographic studies (SPECT) of hepatic arterial perfusion scintigraphy (HAPS) in patients with colorectal liver metastases: improved tumour targetting by microspheres with angiotensin II.

    Science.gov (United States)

    Goldberg, J A; Bradnam, M S; Kerr, D J; McKillop, J H; Bessent, R G; McArdle, C S; Willmott, N; George, W D

    1987-12-01

    As intra-arterial chemotherapy for liver metastases of colorectal origin becomes accepted, methods of further improving drug delivery to the tumour have been devised. Degradable microspheres have been shown to reduce regional blood flow by transient arteriolar capillary block, thereby improving uptake of a co-administered drug, when injected into the hepatic artery. In our study of five patients, we combined hepatic arterial perfusion scintigraphy (HAPS) and SPECT to assess the localization of approximately 1 X 10(5) labelled microspheres of human serum albumin (99Tcm MSA) in tumour. In addition, in three patients, we assessed the effect of an intra-arterial infusion of the vasoactive agent angiotension II during HAPS. Results were interpreted by comparing transaxial slices with corresponding slices of a tin colloid liver-spleen scan. Two of five patients showed good localization of 99Tcm MSA in tumour without an angiotensin II infusion. Of the three patients receiving angiotensin II, all showed good tumour targetting with the vasoconstrictor compared with only one of these three before its use. Thus, hepatic arterial infusion of angiotensin II greatly improves microsphere localization in tumour in some patients with colorectal liver metastases. This technique may be useful in the assessment of tumour targetting before and during locoregional therapy.

  17. In-situ X-ray tomographic study of the morphological changes of a Si/C paper anode for Li-ion batteries

    Science.gov (United States)

    Vanpeene, V.; Etiemble, A.; Bonnin, A.; Maire, E.; Roué, L.

    2017-05-01

    The evolution of the three-dimensional (3D) morphology of a Si-based electrode upon cycling (1st discharge, 1st charge and 2nd discharge) is studied by in-situ synchrotron X-ray tomography. The Si-based electrode is constituted of silicon/carbon black/carboxymethylcellulose (Si/CB/CMC) embedded in a commercial carbon fiber paper, acting as a flexible 3D current collector. Its initial areal discharge capacity is 4.9 mAh cm-2. A reconstructed volume of 293 × 293 × 137 μm3 is analyzed with a resolution of ∼0.3 μm. Three phases are identified: (i) the solid phase (C fibers + Si + CB + CMC), (ii) the electrolyte phase (pores filled with electrolyte) and (iii) the gas phase (electrolyte-free pores). Their respective volume fraction, size distribution and connectivity, and also the dimensional changes of the electrode along the three axes are quantified during cycling. At the beginning of the 1st discharge (lithiation), the formation of gas channels attributed to the reductive electrolyte decomposition is observed. During the 1st charge, large cracks are formed through the electrode, which reclose during the subsequent discharge. The electrode expansion/contraction due to the Si volume change is partially irreversible, occurs mainly in the transverse direction and is much larger in the bottom part of the electrode.

  18. Morphological analysis of the vestibular aqueduct by computerized tomography images

    International Nuclear Information System (INIS)

    Marques, Sergio Ricardo; Smith, Ricardo Luiz; Isotani, Sadao; Alonso, Luis Garcia; Anadao, Carlos Augusto; Prates, Jose Carlos; Lederman, Henrique Manoel

    2007-01-01

    Objective: In the last two decades, advances in the computerized tomography (CT) field revise the internal and medium ear evaluation. Therefore, the aim of this study is to analyze the morphology and morphometric aspects of the vestibular aqueduct on the basis of computerized tomography images (CTI). Material and method: Computerized tomography images of vestibular aqueducts were acquired from patients (n = 110) with an age range of 1-92 years. Thereafter, from the vestibular aqueducts images a morphometric analysis was performed. Through a computerized image processing system, the vestibular aqueduct measurements comprised of its area, external opening, length and the distance from the vestibular aqueduct to the internal acoustic meatus. Results: The morphology of the vestibular aqueduct may be funnel-shaped, filiform or tubular and the respective proportions were found to be at 44%, 33% and 22% in children and 21.7%, 53.3% and 25% in adults. The morphometric data showed to be of 4.86 mm 2 of area, 2.24 mm of the external opening, 4.73 mm of length and 11.88 mm of the distance from the vestibular aqueduct to the internal acoustic meatus, in children, and in adults it was of 4.93 mm 2 , 2.09 mm, 4.44 mm, and 11.35 mm, respectively. Conclusions: Computerized tomography showed that the vestibular aqueduct presents high morphological variability. The morphometric analysis showed that the differences found between groups of children and adults or between groups of both genders were not statistically significant

  19. Effects of dose reduction on multi-detector computed tomographic images in evaluating the maxilla and mandible for pre-surgical implant planning: a cadaveric study.

    Science.gov (United States)

    Koizumi, Hiroshi; Sur, Jaideep; Seki, Kenji; Nakajima, Koh; Sano, Tsukasa; Okano, Tomohiro

    2010-08-01

    To assess effects of dose reduction on image quality in evaluating maxilla and mandible for pre-surgical implant planning using cadavers. Six cadavers were used for the study using multi-detector computed tomography (CT) operated at 120 kV and the variable tube current of 80, 40, 20 and 10 mA. A slice thickness of 0.625 mm and pitch 1 were used. Multi-planar images perpendicular and parallel to dentitions were created. The images were evaluated by five oral radiologists in terms of visibility of the anatomical landmarks including alveolar crest, mandibular canal, floors of the maxillary sinus and nasal cavity, contours/cortical layer of jaw bones and the details of trabecular bone. Observers were asked to determine the quality of the images in comparison with 80 mA images based on the criteria: excellent, good, fair or non-diagnostic. The average scores of all observers were calculated for each specimen in all exposure conditions. The 40 mA images could visualize such landmarks and were evaluated to be same or almost equivalent in quality to the 80 mA images. Even the 20 mA images could be accepted just for diagnostic purpose for implant with substantial deterioration of the image quality. The 10 mA images may not be accepted because of the obscured contour caused by image noise. Significant dose reduction by lowering mA can be utilized for pre-surgical implant planning in multi-detector CT.

  20. A computed tomographic anatomical study of the upper sacrum. Application for a user guide of pelvic fixation with iliosacral screws in adult spinal deformity.

    Science.gov (United States)

    Dubory, Arnaud; Bouloussa, Houssam; Riouallon, Guillaume; Wolff, Stéphane

    2017-12-01

    Widely used in traumatic pelvic ring fractures, the iliosacral (IS) screw technique for spino-pelvic fixation remains anecdotal in adult spinal deformity. The objective of this study was to assess anatomical variability of the adult upper sacrum and to provide a user guide of spino-pelvic fixation with IS screws in adult spinal deformity. Anatomical variability of the upper sacrum according to age, gender, height and weight was sought on 30 consecutive pelvic CT-scans. Thus, a user guide of spino-pelvic fixation with IS screws was modeled and assessed on ten CT-scans as described below. Two invariable landmarks usable during the surgical procedure were defined: point A (corresponding to the connector binding the IS screw to the spinal rod), equidistant from the first posterior sacral hole and the base of the S1 articular facet and 10 mm-embedded into the sacrum; point B (corresponding to the tip of the IS screw) located at the junction of the anterior third and middle third of the sacral endplate in the sagittal plane and at the middle of the endplate in the coronal plane. Point C corresponded to the intersection between the A-B direction and the external facet of the iliac wing. Three-dimensional reconstructions modeling the IS screw optimal direction according to the A-B-C straight line were assessed. Age had no effect on the anatomy of the upper sacrum. The distance between the base of the S1 superior articular facet and the top of the first posterior sacral hole was correlated with weight (r = 0.6; 95% CI [0.6-0.9]); p guide of spinopelvic fixation with IS screws seems to be reliable and reproducible independently of age, gender and morphologic characteristics but needs clinical assessment. Level IV.